WorldWideScience

Sample records for line pulse shortening

  1. Strategies for shortening the output pulse of silicon photomultipliers

    Antoranz Canales, Pedro; Miranda Pantoja, José Miguel; Yebras Rivera, José Manuel

    2012-01-01

    In this work, three strategies for shortening the output pulse of a silicon photomultiplier (SiPM) are reported. The first strategy is passive filtering, where band-pass filtering removes the lowest frequency components in the signal, getting a noticeable reduction in pulse width (a compression ratio of 10: 1 was obtained). In the second place, a reflectometric scheme is proposed where the amplified signal coming from the SiPM is injected into a signal splitter with one of its stubs connected...

  2. Power electron beam front shortening in magnetically insulated transmission line with inner coaxial dielectric insert

    Galstjan, E.A.; Kazanskiy, L.N.

    1995-01-01

    By now the technology of high-power high-current relativistic electron beams with microsecond duration has been developed. The same technology is used in high-power electric pulse generation. However at present the high-power beams of subnanosecond duration are necessary for some investigations and applications. The maximum power parameter achieved by means of the usual technology is limited by a value in the range of 100-300 MW. For this reason a search for new ways to generate high-power REB (relativistic electron beam) is a topical problem. It is obvious that this problem may be reduced to the generation of pulses with a subnanosecond front duration. There are many methods to shorten a pulse duration to its front duration for instance, by using parts of short-circuited transmission lines

  3. Bipolar pulse forming line

    Rhodes, Mark A.

    2008-10-21

    A bipolar pulse forming transmission line module for linear induction accelerators having first, second, third, fourth, and fifth planar conductors which form an interleaved stack with dielectric layers between the conductors. Each conductor has a first end, and a second end adjacent an acceleration axis. The first and second planar conductors are connected to each other at the second ends, the fourth and fifth planar conductors are connected to each other at the second ends, and the first and fifth planar conductors are connected to each other at the first ends via a shorting plate adjacent the first ends. The third planar conductor is electrically connectable to a high voltage source, and an internal switch functions to short a high voltage from the first end of the third planar conductor to the first end of the fourth planar conductor to produce a bipolar pulse at the acceleration axis with a zero net time integral. Improved access to the switch is enabled by an aperture through the shorting plate and the proximity of the aperture to the switch.

  4. Coiled transmission line pulse generators

    McDonald, Kenneth Fox

    2010-11-09

    Methods and apparatus are provided for fabricating and constructing solid dielectric "Coiled Transmission Line" pulse generators in radial or axial coiled geometries. The pour and cure fabrication process enables a wide variety of geometries and form factors. The volume between the conductors is filled with liquid blends of monomers, polymers, oligomers, and/or cross-linkers and dielectric powders; and then cured to form high field strength and high dielectric constant solid dielectric transmission lines that intrinsically produce ideal rectangular high voltage pulses when charged and switched into matched impedance loads. Voltage levels may be increased by Marx and/or Blumlein principles incorporating spark gap or, preferentially, solid state switches (such as optically triggered thyristors) which produce reliable, high repetition rate operation. Moreover, these Marxed pulse generators can be DC charged and do not require additional pulse forming circuitry, pulse forming lines, transformers, or an a high voltage spark gap output switch. The apparatus accommodates a wide range of voltages, impedances, pulse durations, pulse repetition rates, and duty cycles. The resulting mobile or flight platform friendly cylindrical geometric configuration is much more compact, light-weight, and robust than conventional linear geometries, or pulse generators constructed from conventional components. Installing additional circuitry may accommodate optional pulse shape improvements. The Coiled Transmission Lines can also be connected in parallel to decrease the impedance, or in series to increase the pulse length.

  5. CO2 laser pulse shortening by laser ablation of a metal target

    Donnelly, T.; Mazoyer, M.; Lynch, A.; O'Sullivan, G.; O'Reilly, F.; Dunne, P.; Cummins, T.

    2012-01-01

    A repeatable and flexible technique for pulse shortening of laser pulses has been applied to transversely excited atmospheric (TEA) CO 2 laser pulses. The technique involves focusing the laser output onto a highly reflective metal target so that plasma is formed, which then operates as a shutter due to strong laser absorption and scattering. Precise control of the focused laser intensity allows for timing of the shutter so that different temporal portions of the pulse can be reflected from the target surface before plasma formation occurs. This type of shutter enables one to reduce the pulse duration down to ∼2 ns and to remove the low power, long duration tails that are present in TEA CO 2 pulses. The transmitted energy is reduced as the pulse duration is decreased but the reflected power is ∼10 MW for all pulse durations. A simple laser heating model verifies that the pulse shortening depends directly on the plasma formation time, which in turn is dependent on the applied laser intensity. It is envisaged that this plasma shutter will be used as a tool for pulse shaping in the search for laser pulse conditions to optimize conversion efficiency from laser energy to useable extreme ultraviolet (EUV) radiation for EUV source development.

  6. Assembly delay line pulse generators

    CERN PhotoLab

    1971-01-01

    Assembly of six of the ten delay line pulse generators that will power the ten kicker magnet modules. One modulator part contains two pulse generators. Capacitors, inductances, and voltage dividers are in the oil tank on the left. Triggered high-pressure spark gap switches are on the platforms on the right. High voltage pulse cables to the kicker magnet emerge under the spark gaps. In the centre background are the assembled master gaps.

  7. Femtosecond pulse self-shortening in Kerr media: role of modulational instability in the spectrum formation

    Grudtsyn, Ya. V.; Koribut, A. V.; Mikheev, L. D.; Trofimov, V. A.

    2018-04-01

    The mechanism of femtosecond pulse self-shortening in thin optical materials with Kerr nonlinearity is investigated. The experimentally observed spectral-angular distribution of the radiation intensity on the exit surface of a 1-mm-thick fused silica sample is compared with the results of numerical simulation based on solving the nonlinear Schrödinger equation for an electromagnetic wave with a transverse perturbation on the axis. Qualitative agreement between the calculated and experimental results confirms the hypothesis about the transient regime of multiple filamentation as a mechanism of femtosecond pulse self-shortening.

  8. High-explosive-driven delay line pulse generator

    Shearer, J.W.

    1982-01-01

    The inclusion of a delay line circuit into the design of a high-explosive-driven generator shortens the time constant of the output pulse. After a brief review of generator concepts and previously described pulse-shortening methods, a geometry is presented which incorporates delay line circuit techcniques into a coil generator. The circuit constants are adjusted to match the velocity of the generated electromagnetic wave to the detonation velocity of the high explosive. The proposed generator can be modeled by adding a variable inductance term to the telegrapher's equation. A particular solution of this equation is useful for exploring the operational parameters of the generator. The duration of the electromagnetic pulse equals the radial expansion time of the high-explosive-driven armature until it strikes the coil. Because the impedance of the generator is a constant, the current multiplication factor is limited only by nonlinear effects such as voltage breakdown, diffusion, and compression at high energies

  9. Magnetic pulse sharpener and delay-line

    Li Jin; Dai Guangsen; Xia Liansheng

    2002-01-01

    This paper describes a method to achieve short rise time pulse which has been delayed with a delay-line and magnetic pulse sharpener. A delay-line and two shock-lines are designed to carry pulsed signal with a maximum voltage magnitude up to 80 kV. A pulse of High voltage with arise time of 48 ns at a level of 0.1%-0.9% were achieved, and the attenuation in the line is very small

  10. Unsplit bipolar pulse forming line

    Rhodes, Mark A [Pleasanton, CA

    2011-05-24

    A bipolar pulse forming transmission line module and system for linear induction accelerators having first, second, third, and fourth planar conductors which form a sequentially arranged interleaved stack having opposing first and second ends, with dielectric layers between the conductors. The first and second planar conductors are connected to each other at the first end, and the first and fourth planar conductors are connected to each other at the second end via a shorting plate. The third planar conductor is electrically connectable to a high voltage source, and an internal switch functions to short at the first end a high voltage from the third planar conductor to the fourth planar conductor to produce a bipolar pulse at the acceleration axis with a zero net time integral. Improved access to the switch is enabled by an aperture through the shorting plate and the proximity of the aperture to the switch.

  11. The Pulse Line Ion Accelerator Concept

    Briggs, Richard J.

    2006-02-15

    The Pulse Line Ion Accelerator concept was motivated by the desire for an inexpensive way to accelerate intense short pulse heavy ion beams to regimes of interest for studies of High Energy Density Physics and Warm Dense Matter. A pulse power driver applied at one end of a helical pulse line creates a traveling wave pulse that accelerates and axially confines the heavy ion beam pulse. Acceleration scenarios with constant parameter helical lines are described which result in output energies of a single stage much larger than the several hundred kilovolt peak voltages on the line, with a goal of 3-5 MeV/meter acceleration gradients. The concept might be described crudely as an ''air core'' induction linac where the PFN is integrated into the beam line so the accelerating voltage pulse can move along with the ions to get voltage multiplication.

  12. Operative shortening of the sling as a second-line treatment after TVT failure

    Matuszewski, Marcin; Michajłowski, Jerzy; Krajka, Kazimierz

    2011-01-01

    Introduction Stress urinary incontinence (SUI) is defined as an involuntary loss of urine during physical exertion, sneezing, coughing, laughing, or other activities that put pressure on the bladder. In some cases, recurrent or persistent SUI after sling operations may be caused by too loose placement of the sling. In the current study, we describe our method of shortening of the sling as a second-line treatment of tension-free vaginal tape (TVT) failure. Materials and methods Four women, aged 46-61, after initial TVT operation were treated for persistent SUI. The severity of SUI was estimated by: physical examinations, cough tests, 24-h pad tests, and King's Health Questionnaire. The shortening procedure, based on excising the fragment of tape and suturing it back, was performed in all patients. Results All cases achieved a good result, which was defined as restoration of full continence. No complications occurred. The 12-month follow-up showed no side-effects. The postoperative control tests: the cough and 24-h pad tests were negative in all women. The general health perceptions increased after the shortening procedure by a mean value 44.25%. The incontinence impact decreased by a mean value 44.6%. In all patients, role and physical limitations significantly decreased (by 88.5% and 80.5%, respectively). The negative emotions connected with SUI significantly decreased after the second procedure. Conclusions The operative shortening of the implanted sling is a simple, cheap, and effective method of second-line treatment in cases of TVT failure and may be offered to the majority of patients with insufficient urethral support after the first procedure. PMID:24578885

  13. On the Transmission Line Pulse Measurement Technique

    X. Rodriguez; M. Eduardo; M. Harington

    2015-01-01

    Transmission Line Pulse is a short pulse (25ns to 150ns) measurement of the current-voltage (I/V) characteristics of the ESD protection built into an integrated circuit. The short TLP pulses are used to simulate the short ESD pulse threats and integrated circuit must tolerate without being damaged. In this work the fundamental principles of how the TLP pulse is generated and used to create I-V characteristic plots will be explored. The measurement will be then used to characterize the I-V cha...

  14. Overview of The Pulse Line Ion Accelerator

    Briggs, R.J.; Bieniosek, F.M.; Coleman, J.E.; Eylon, S.; Henestroza, E.; Leitner, M.; Logan, B.G.; Reginato, L.L.; Roy, P.K.; Seidl, P.A.; Waldron, W.L.; Yu, S.S.; Barnard, J.J.; Caporaso, G.J.; Friedman, A.; Grote, D.P.; Nelson, S.D.

    2006-01-01

    An overview of the Pulse Line Ion Accelerator (PLIA) concept and its development is presented. In the PLIA concept a pulse power driver applied to one end of a helical pulse line creates a traveling wave pulse that accelerates and axially confines a heavy ion beam pulse The motivation for its development at the IFE-VNL is the acceleration of intense, short pulse, heavy ion beams to regimes of interest for studies of High Energy Density Physics and Warm Dense Matter. Acceleration scenarios with constant parameter helical lines are described which result in output energies of a single stage much larger than the several hundred kilovolt peak voltages on the line, with a goal of 3-5 MeV/meter acceleration gradients. The main attraction of the concept is the very low cost it promises. It might be described crudely as an ''air core'' induction linac where the pulse-forming network is integrated into the beam line so the accelerating voltage pulse can move along with the ions to get voltage multiplication

  15. Use of TCSR with Split Windings for Shortening the Spar Cycle Time in 500 kV Lines

    Matinyan, A. M., E-mail: al-drm@mail.ru; Peshkov, M. V.; Karpov, V. N.; Alekseev, N. A. [JSC “R& D Center at Federal Grid Company of Unified Power System,” (Russian Federation)

    2017-01-15

    The arc-fault recharge phenomenon in single-phase automatic reclosure (SPAR) of a line is examined. Abrief description is given of the design of a 500 kV thyristor controlled shunt reactor (TCSR) with split valve-side windings. This type of TCSR is shown to effectively quench a single-phase arc fault in a power transmission line and shortens the SPAR cycle time.

  16. Effect of splitting a mixed-model line on shortening the line length under open- and closed-boundary working area settings

    Zhang, Donghao; Matsuura, Haruki; Asada, Akiko

    2017-04-01

    Some automobile factories have segmented mixed-model production lines into shorter sub-lines according to part group, such as engine, trim, and powertrain. The effects of splitting a line into sub-lines have been reported from the standpoints of worker motivation, productivity improvement, and autonomy based on risk spreading. There has been no mention of the possibility of shortening the line length by altering the product sequence using sub-lines. The purpose of the present paper is to determine the conditions under which sub-lines reduce the line length and the degree to which the line length may be shortened. The line lengths for a non-split line and a line that has been split into sub-lines are compared using three methods for determining the working area, the standard closed boundary, the optimized open boundary, and real-life constant-length stations. The results are discussed by analyzing the upper and lower bounds of the line length. Based on these results, a procedure for deciding whether or not to split a production line is proposed.

  17. Shortened first-line TB treatment in Brazil: potential cost savings for patients and health services

    Trajman, Anete; Bastos, Mayara Lisboa; Belo, Marcia; Calaça, Janaína; Gaspar, Júlia; Dos Santos, Alexandre Martins; Dos Santos, Camila Martins; Brito, Raquel Trindade; Wells, William A.; Cobelens, Frank G.; Vassall, Anna; Gomez, Gabriela B.

    2016-01-01

    Shortened treatment regimens for tuberculosis are under development to improve treatment outcomes and reduce costs. We estimated potential savings from a societal perspective in Brazil following the introduction of a hypothetical four-month regimen for tuberculosis treatment. Data were gathered in

  18. Apoptosis and telomeres shortening related to HIV-1 induced oxidative stress in an astrocytoma cell line

    Mollace Vincenzo

    2009-05-01

    Full Text Available Abstract Background Oxidative stress plays a key role in the neuropathogenesis of Human Immunodeficiency Virus-1 (HIV-1 infection causing apoptosis of astroglia cells and neurons. Recent data have shown that oxidative stress is also responsible for the acceleration of human fibroblast telomere shortening in vitro. In the present study we analyzed the potential relations occurring between free radicals formation and telomere length during HIV-1 mediated astroglial death. Results To this end, U373 human astrocytoma cells have been directly exposed to X4-using HIV-1IIIB strain, for 1, 3 or 5 days and treated (where requested with N-acetylcysteine (NAC, a cysteine donor involved in the synthesis of glutathione (GSH, a cellular antioxidant and apoptosis has been evaluated by FACS analysis. Quantitative-FISH (Q-FISH has been employed for studying the telomere length while intracellular reduced/oxidized glutathione (GSH/GSSG ratio has been determined by High-Performance Liquid Chromatography (HPLC. Incubation of U373 with HIV-1IIIB led to significant induction of cellular apoptosis that was reduced in the presence of 1 mM NAC. Moreover, NAC improved the GSH/GSSG, a sensitive indicator of oxidative stress, that significantly decreased after HIV-1IIIB exposure in U373. Analysis of telomere length in HIV-1 exposed U373 showed a statistically significant telomere shortening, that was completely reverted in NAC-treated U373. Conclusion Our results support the role of HIV-1-mediated oxidative stress in astrocytic death and the importance of antioxidant compounds in preventing these cellular damages. Moreover, these data indicate that the telomere structure, target for oxidative damage, could be the key sensor of cell apoptosis induced by oxidative stress after HIV infection.

  19. Optocoupled line receiver input discriminates against narrow noise pulses

    Napier, T M

    1977-01-01

    Describes a simple optocoupled interface which connects a data line to the receiving end of a data link that features pulse length discrimination to enhance noise pulse rejection. A rugged red LED, D /sub 1/, can bypass any reasonable fault currents to protect the relatively fragile optocoupler input diode. (0 refs).

  20. Long-pulse applications of pulse-forming lines for high-power linac application

    Hoeberling, R.F.; Tallerico, P.J.

    1981-01-01

    The ever present demands for high efficiency in the RF power stations for particle accelerators have caused increased interest in longer RF pulses (ten's of microseconds) for linacs such as the Pion Generator for Medical Irradiation (PIGMI) and Free Electron Laser (FEL). For either RF power station, a fundamental decision is whether to use a modulating anode/hard-tube driver or pulsed cathode/line-type pulser configuration. The choices in the extremes of low power for very long pulses or for very-high-power, short pulses are, respectively, a modulated anode/hard tube modulator and pulsed cathode/pulse forming line. However, the demarcation between these two extremes is not clearcut. The criteria (cost, flexibility performance, reliability, efficiency) that resulted in the RF station definition of these two specific systems will be described

  1. The Study for Shortening the Process Time at Soy Food Production by using the Pulsed Electric Field

    Saito, Tsukasa; Jinushi, Makoto; Minamitani, Yasushi

    We investigated method to osmose water and seasoner to dried soybeans fast by pulsed electric field, in order to make soybeans a processed food fast. By applying the pulsed electric field to the dried soybeans in water, osmosis time of water to the soybean became approximately half. Then the emission of the discharge was observed on dried soybean. The color of coffee permeated more into the soybean treated than no-treated by the pulsed electric field.

  2. Toeless pulse shaping with a single delay-line network

    Tauhata, L.; Binns, D.C.

    1976-04-01

    New unipolar delay-line clippers producing negligible cancellation remnant have been developed. Near perfect clipping is achieved using a combination of several types of coaxial cable tranformers working as a phase inverter, a new pulse adder, or an impedance transformer. Only passive elements are used in the bridge network. The construction is simple and the performance is extremely stable and wide in dynamic range and frequency band width. Completely symmetrical bipolar pulses are also easily obtained using this technique

  3. Matching problems in pulse power radial transmission lines

    Mittag, K.; Brandelik, A.

    1984-12-01

    In this report we study the power transfer from a generator along a coaxial transmission line followed by a radial transmission line into a load, which in our application is a pseudo-spark plasma of about one millimeter diameter and about 15 cm in length. First the theoretical background based on transmission line theory is described. Then numerical results are presented. The main conclusion is that when matching the pulse power generator to the pseudo-spark plasma, the effect of the impedance transformation caused by the radial transmission line has to be taken into account. The conditions to obtain an optimal match are described. (orig.) [de

  4. A chopper system for shortening the duration of pulsed supersonic beams seeded with NO or Br2 down to 13 μs.

    Lam, Jessica; Rennick, Christopher J; Softley, Timothy P

    2015-05-01

    A chopper wheel construct is used to shorten the duration of a molecular beam to 13 μs. Molecular beams seeded with NO or with Br2 and an initial pulse width of ≥200 μs were passed through a spinning chopper wheel, which was driven by a brushless DC in vacuo motor at a range of speeds, from 3000 rpm to 80,000 rpm. The resulting duration of the molecular-beam pulses measured at the laser detection volume ranged from 80 μs to 13 μs and was the same for both NO and Br2. The duration is consistent with a simple analytical model, and the minimum pulse width measured is limited by the spreading of the beam between the chopper and the detection point as a consequence of the longitudinal velocity distribution of the beam. The setup adopted here effectively eliminates buildup of background gas without the use of a differential pumping stage, and a clean narrow pulse is obtained with low rotational temperature.

  5. Real-time pulse deinterleaving using digital delay line techniques

    Lentz, L. F.; Palermo, T. J.

    This paper describes an implementation of a tracking pulse sorter based on predictive gating techniques. Real-time pulse sorters or pulse train gating devices have been utilized by the ELINT signal analyst for many years. The more elementary of these devices employed a retriggerable delay interval and an acceptance gate, which were used in predictive fashion to track pulse trains whose PRIs fall within the limits of the programmed delay interval. This design utilizes the pulse hit/miss history of individual track files in a variation of a sequential observer detection algorithm. Use of a digital delay line with pulse history allows multiple pulse trains to be tracked simultaneously and independently without interference. The design also provides flexibility in lock-on and track criteria to allow maintenance of acquisition probability and false alarm rate in dense signal environments and with low SNRs. The hardware provides time interval resolution to 12.5 nsec and covers a PRI range of 50 microsec to 50 msec.

  6. Effect of inductance between middle and outer cylinders on diode voltage of pulse forming line

    Liu Jinliang; Wang Xinxin

    2008-01-01

    Based on the experimental device of the water spiral pulse forming line(PFL) type electron beam accelerator, the effect of inductance between the middle and outer cylinders of PFL on diode voltage is theoretically and experimentally studied in this paper. The formulae are introduced, with which the effect of inductance on diode voltage is calculated. In addition, the diode voltage waveform is simulated through the Pspice software. The theoretical and simulated results agree well with the experimental results, which show that large inductance between middle and outer cylinders can shorten the waveform flat part of diode voltage, increase waveform rise time and reduce the diode peak voltage. When the inductance is smaller than 200 nH, a nearly square voltage waveform can be obtained in field-emission diode. (authors)

  7. Construction of a pulsed MeV positron beam line

    Masuno, Shin-ichi; Okada, Sohei; Kawasuso, Atsuo [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    To develop a fast (1 MeV) and short pulsed (100 ps) positron beam which enables defect behavior analysis of bulk states of materials even at high temperatures where a usual positron source would melt, we have been performing design study and construction of the beam line in a three-year program since 1994. This report describes the components, design study results and experimental results of the completed parts until now. (author)

  8. Stark widths of Xe II lines in a pulsed plasma

    Djurovic, S; Pelaez, R J; Cirisan, M; Aparicio, J A; Mar, S

    2006-01-01

    In this paper, we present a review of experimental work on Stark broadening of singly ionized xenon lines. Eighty lines, from close UV to the red region of the spectrum, have been studied. Stark halfwidths were compared with experimental data from the literature and modified semi-empirical calculations. A pulsed arc with 95% of helium and 5% xenon was used as a plasma source for this study. Measured electron densities N e and temperatures T were in the ranges of 0.2-1.6 x 10 23 m -3 and 18 300-25 500 K, respectively

  9. Linear induction accelerators made from pulse-line cavities with external pulse injection

    Smith, I.

    1979-01-01

    Two types of linear induction accelerator have been reported previously. In one, unidirectional voltage pulses are generated outside the accelerator and injected into the accelerator cavity modules, which contain ferromagnetic material to reduce energy losses in the form of currents induced, in parallel with the beam, in the cavity structure. In the other type, the accelerator cavity modules are themselves pulse-forming lines with energy storage and switches; parallel current losses are made zero by the use of circuits that generate bidirectional acceleration waveforms with a zero voltage-time integral. In a third type of design described here, the cavities are externally driven, and 100% efficient coupling of energy to the beam is obtained by designing the external pulse generators to produce bidirectional voltage waveforms with zero voltage-time integral. A design for such a pulse generator is described that is itself one hundred percent efficient and which is well suited to existing pulse power techniques. Two accelerator cavity designs are described that can couple the pulse from such a generator to the beam; one of these designs provides voltage doubling. Comparison is made between the accelerating gradients that can be obtained with this and the preceding types of induction accelerator

  10. A Delay Line for Compression of Electromagnetic Pulses

    Pchelnikov, Yuriy N.; Nyce, David S.

    2003-01-01

    A novel method to obtain an electromagnetic signal delay is described. It is shown that the positive magnetic and electric coupling between impedance conductors produces an increase in the time delay. It is also shown that the increase in delay time is obtained without additional attenuation. This allows a reduction in electromagnetic losses, by a factor of several times, for a delay time. An approximate analysis of electromagnetic delay lines based on coupled impedance conductors with 'spiral' and 'meander' patterns allowed obtaining very simple expressions for the wave deceleration factor, wave impedance, and attenuation factor. The results of the analysis are confirmed by the results of measurements. It is shown that a delay line based on counter-wound radial spirals can be successfully used for compression of electromagnetic pulses. Although the offered delay line was designed to operate with a relatively small signal, the analysis of the 'coupling effect', taking place in this delay line, might be useful in devices for compression of high-power microwave pulses

  11. Bidirectional pulser made from pulse lines for linear induction accelerators

    Hotta, E.; Mori, T.; Kobayashi, T.; Okino, A.; Haginomori, E.; Ko, K.C.

    1996-01-01

    In order to obtain high-current charged particle beams, linear induction accelerators (LIA's) of two types have been already constructed. Conventional LIA's adopt a unidirectional pulse injected from an external pulser. The other LIA's, one of which has been proposed and constructed by Pavlovskii et al., have accelerating cavities made from pulse forming lines (PFL's). In this case, no magnetic core loaded in the cavity is necessary. However, the injected pulse must be a bidirectional one. Since a part of the voltage pulse with reversed polarity is used to accelerate a beam, it is possible to make the time integral of the output voltage zero. Thus the final magnetic energy stored in the cavity can be made zero at the end of the pulse, and the pulser-accelerator system attains the energy transfer efficiency of 100%. Accelerators of this type can be divided into two kinds, one of which has cavities with internal energy storage, and the other has cavities with energy injected from external bidirectional pulsers. The accelerator of latter type has been first proposed by Smith, but it has not been realized. Several bidirectional pulsers, which consist of three individual PFL's with arbitrary impedances and a closing switch, are analyzed. Output voltages are analytically calculated by using the method proposed by Dommel for digital computations of electromagnetic transients in networks, and conditions for attaining the maximum efficiency of energy transfer from the pulser to the beam are derived. Thus, 4 bidirectional pulsers of internal energy storage type and 2 of external pulse injection type with energy transfer efficiency of 100% are obtained, including the pulsers already reported by other authors

  12. Programmable pulse sequence generator with multiple output lines

    Drabczyk, Hubert

    2006-10-01

    This paper presents a novel concept of pulse sequence generator and its prototype as an electronic circuit testing laboratory tool. The generator has multiple output lines and is capable of using control data defining different pulse sequences to be given to the outputs. It is also possible to use different voltage levels in output signal and switch output lines for reading data from driven system. The pulse sequence generator can be used for runtime environment simulation, as hardware tester or auxiliary tool in new designs. Important design factors were to keep cost of the tool low and allow integration with other projects by using flexible architecture. The prototype was based on universal programmer with adjustable power supply, '51 microcontroller and Altera Cyclone chip. The generator communicates witch PC computer via RS232 port. Dedicated software was developed in the course of this project, to control the tool and data transmission. The prototype confirmed the possibility to create an inexpensive multipurpose laboratory tool for programming, testing and simulation of digital devices.

  13. Fully controlled 5-phase, 10-pulse, line commutated rectifier

    Mahmoud I. Masoud

    2015-12-01

    Full Text Available The development and production of multiphase machines either generators or motors, specially five-phase, offers improved performance compared to three-phase counterpart. Five phase generators could generate power in applications such as, but not limited to, wind power generation, electric vehicles, aerospace, and oil and gas. The five-phase generator output requires converter system such as ac–dc converters. In this paper, a fully controlled 10-pulse line commutated rectifier, suitable to be engaged with wind energy applications, fed from five-phase source is introduced. A shunt active power filter (APF is used to improve power factor and supply current total harmonic distortion (THD. Compared to three-phase converters, 6-pulse or 12-pulse rectifiers, the 10-pulse rectifier engaged with 5-phase source alleviate their drawbacks such as high dc ripples and no need for electric gear or phase shifting transformer. MATLAB/SIMULINK platform is used as a simulation tool to investigate the performance of the proposed rectifier.

  14. Multistage linear electron acceleration using pulsed transmission lines

    Miller, R.B.; Prestwich, K.R.; Poukey, J.W.; Epstein, B.G.; Freeman, J.R.; Sharpe, A.W.; Tucker, W.K.; Shope, S.L.

    1981-01-01

    A four-stage linear electron accelerator is described which uses pulsed radial transmission lines as the basic accelerating units. An annular electron beam produced by a foilless diode is guided through the accelerator by a strong axial magnetic field. Synchronous firing of the injector and the acccelerating modules is accomplished with self-breaking oil switches. The device has accelerated beam currents of 25 kA to kinetic energies of 9 MV, with 90% current transport efficiency. The average accelerating gradient is 3 MV/m

  15. PSPICE simulation of bipolar pulse converter based on short-circuited coaxial transmission line

    Shi Lei; Fan Yajun

    2010-01-01

    The operating principle of the bipolar pulse converter based on short-circuited coaxial transmission line type is given. The output bipolar pulses are simulated by using PSPICE program on condition of different electric length and different impedance of the short-circuited coaxial transmission line. The bipolar pulses are generated by using unipolar pulse with pulse width of 2 ns in experiment, the experimental result fit well with the simulation result. (authors)

  16. Long-distance pulse propagation on high-frequency dissipative nonlinear transmission lines/resonant tunneling diode line cascaded maps

    Klofai, Yerima; Essimbi, B Z; Jaeger, D

    2011-01-01

    Pulse propagation on high-frequency dissipative nonlinear transmission lines (NLTLs)/resonant tunneling diode line cascaded maps is investigated for long-distance propagation of short pulses. Applying perturbative analysis, we show that the dynamics of each line is reduced to an expanded Korteweg-de Vries-Burgers equation. Moreover, it is found by computer experiments that the soliton developed in NLTLs experiences an exponential amplitude decay on the one hand and an exponential amplitude growth on the other. As a result, the behavior of a pulse in special electrical networks made of concatenated pieces of lines is closely similar to the transmission of information in optical/electrical communication systems.

  17. Long-distance pulse propagation on high-frequency dissipative nonlinear transmission lines/resonant tunneling diode line cascaded maps

    Klofai, Yerima [Department of Physics, Higher Teacher Training College, University of Maroua, PO Box 46 Maroua (Cameroon); Essimbi, B Z [Department of Physics, Faculty of Science, University of Yaounde 1, PO Box 812 Yaounde (Cameroon); Jaeger, D, E-mail: bessimb@yahoo.fr [ZHO, Optoelectronik, Universitaet Duisburg-Essen, D-47048 Duisburg (Germany)

    2011-10-15

    Pulse propagation on high-frequency dissipative nonlinear transmission lines (NLTLs)/resonant tunneling diode line cascaded maps is investigated for long-distance propagation of short pulses. Applying perturbative analysis, we show that the dynamics of each line is reduced to an expanded Korteweg-de Vries-Burgers equation. Moreover, it is found by computer experiments that the soliton developed in NLTLs experiences an exponential amplitude decay on the one hand and an exponential amplitude growth on the other. As a result, the behavior of a pulse in special electrical networks made of concatenated pieces of lines is closely similar to the transmission of information in optical/electrical communication systems.

  18. Annular shape silver lined proportional counter for on-line pulsed neutron yield measurement

    Dighe, P.M.; Das, D.

    2015-01-01

    An annular shape silver lined proportional counter is developed to measure pulsed neutron radiation. The detector has 314 mm overall length and 235 mm overall diameter. The central cavity of 150 mm diameter and 200 mm length is used for placing the neutron source. Because of annular shape the detector covers >3π solid angle of the source. The detector has all welded construction. The detector is developed in two halves for easy mounting and demounting. Each half is an independent detector. Both the halves together give single neutron pulse calibration constant of 4.5×10 4 neutrons/shot count. The detector operates in proportional mode which gives enhanced working conditions in terms of dead time and operating range compared to Geiger Muller based neutron detectors

  19. Gyromagnetic nonlinear transmission line generator of high voltage pulses modulated at 4 GHz frequency with 1000 Hz pulse repetition rate

    Ulmasculov, M R; Sharypov, K A; Shunailov, S A; Shpak, V G; Yalandin, M I; Pedos, M S; Rukin, S N

    2017-01-01

    Results of testing of a generator based on a solid-state drive and the parallel gyromagnetic nonlinear transmission lines with external bias are presented. Stable rf-modulated high-voltage nanosecond pulses were shaped in each of the four channels in 1 s packets with 1000 Hz repetition frequencies. Pulse amplitude reaches -175 kV, at a modulation depth of rf-oscillations to 50 % and the effective frequency ∼4 GHz. (paper)

  20. The detailed characteristics of positive corona current pulses in the line-to-plane electrodes

    Xuebao, LI; Dayong, LI; Qian, ZHANG; Yinfei, LI; Xiang, CUI; Tiebing, LU

    2018-05-01

    The corona current pulses generated by corona discharge are the sources of the radio interference from transmission lines and the detailed characteristics of the corona current pulses from conductor should be investigated in order to reveal their generation mechanism. In this paper, the line-to-plane electrodes are designed to measure and analyze the characteristics of corona current pulses from positive corona discharges. The influences of inter-electrode gap and line diameters on the detail characteristics of corona current pulses, such as pulse amplitude, rise time, duration time and repetition frequency, are carefully analyzed. The obtained results show that the pulse amplitude and the repetition frequency increase with the diameter of line electrode when the electric fields on the surface of line electrodes are same. With the increase of inter-electrode gap, the pulse amplitude and the repetition frequency first decrease and then turn to be stable, while the rise time first increases and finally turns to be stable. The distributions of electric field and space charges under the line electrodes are calculated, and the influences of inter-electrode gap and line electrode diameter on the experimental results are qualitatively explained.

  1. A distributed parameter model of transmission line transformer for high voltage nanosecond pulse generation.

    Li, Jiangtao; Zhao, Zheng; Li, Longjie; He, Jiaxin; Li, Chenjie; Wang, Yifeng; Su, Can

    2017-09-01

    A transmission line transformer has potential advantages for nanosecond pulse generation including excellent frequency response and no leakage inductance. The wave propagation process in a secondary mode line is indispensable due to an obvious inside transient electromagnetic transition in this scenario. The equivalent model of the transmission line transformer is crucial for predicting the output waveform and evaluating the effects of magnetic cores on output performance. However, traditional lumped parameter models are not sufficient for nanosecond pulse generation due to the natural neglect of wave propagations in secondary mode lines based on a lumped parameter assumption. In this paper, a distributed parameter model of transmission line transformer was established to investigate wave propagation in the secondary mode line and its influential factors through theoretical analysis and experimental verification. The wave propagation discontinuity in the secondary mode line induced by magnetic cores is emphasized. Characteristics of the magnetic core under a nanosecond pulse were obtained by experiments. Distribution and formation of the secondary mode current were determined for revealing essential wave propagation processes in secondary mode lines. The output waveform and efficiency were found to be affected dramatically by wave propagation discontinuity in secondary mode lines induced by magnetic cores. The proposed distributed parameter model was proved more suitable for nanosecond pulse generation in aspects of secondary mode current, output efficiency, and output waveform. In depth, comprehension of underlying mechanisms and a broader view of the working principle of the transmission line transformer for nanosecond pulse generation can be obtained through this research.

  2. Novel pulse amplifying circuits based on transmission lines of different characteristic impedance

    Belloni, F.; Doria, D.; Lorusso, A.; Nassisi, V.

    2006-01-01

    Two novel circuits used to amplify electric pulses by the coupling of transmission lines of different characteristic impedance are described. The circuits are intended for doubling voltage pulses and for doubling current pulses. The former is composed by a R 0 transmission line closed on a set of two 2R 0 storage lines connected in parallel, while the latter is composed by a R 0 transmission line closed on a set of two R 0 /2 storage lines connected in series. The length of every storage line is half of input-pulse length. In both circuits, one storage line is characterized by an open extremity and the other line by a closed extremity. Connecting opportunely the storage lines to suitable load resistors, 4R 0 and R 0 /4, for the circuit having parallel and series connected lines, respectively, a twice of the output pulse intensity is obtained. Such devices are very suitable to generate high intensity voltage and/or current peaks which are very interesting in the field of the accelerators. Both circuit behaviours have been theoretically studied and verified by computer simulations

  3. Design and development of a high-power, 500 kV pulsed line

    Nicolas, A.

    A study was made of very high voltage (500 kV) pulse production for 50 ns at half height. A coaxial line was coupled to a Marx generator for obtaining the pulses on an impedance-adapted electron diode. The maximum power obtained was 6.4 x 10 10 W with a current front in the diode of about 30 ns (80 ns pulse length at half height)

  4. New schemes for high-voltage pulsed generators based on stepped transmission lines

    Bossamykin, V.S.; Gordeev, V.S.; Pavlovskii, A.I.

    1993-01-01

    Wave processes were analyzed from the point of effective energy delivery in pulsed power systems based on transmission lines. A series of new schemes for the pulsed generators based on multistage stepped transmission lines both with the capacitive and inductive energy storage was found. These devices can provide voltage or current transformation up to 5-10 times due to wave processes if stage's characteristic impedances are in a certain correlation. The schemes suggested can be widely applied in the new powerful pulsed power accelerators. The theoretical conclusions are justified experimentally

  5. Precise ion optical description of strip-line pulsed magnetic lenses

    Varentsov, D.; Spiller, P.; Eickhoff, H.; Hoffmann, D.H.H.

    2002-01-01

    A specific computer code has been developed to investigate ion optical properties of a new generation of pulsed strip-line high current magnets. The code is based on a modern 'Differential Algebra' computational technique and it is able to calculate transfer matrices of pulsed strip-line magnets up to arbitrary order. The realistic three-dimensional distribution of the magnetic field in pulsed lenses as well as all the fringing field effects are taken into account in the simulations. We have demonstrated, that for precise description of such magnets one cannot use the existing ion optical codes where ideal multipole field distributions and fringing fields, typical for conventional iron-dominated magnets are assumed. The transfer matrix elements of pulsed strip-line lenses differ significantly from those of conventional magnets, especially in higher orders

  6. Electric field simulation and measurement of a pulse line ion accelerator

    Shen Xiaokang; Zhang Zimin; Cao Shuchun; Zhao Hongwei; Zhao Quantang; Liu Ming; Jing Yi; Wang Bo; Shen Xiaoli

    2012-01-01

    An oil dielectric helical pulse line to demonstrate the principles of a Pulse Line Ion Accelerator (PLIA) has been designed and fabricated. The simulation of the axial electric field of an accelerator with CST code has been completed and the simulation results show complete agreement with the theoretical calculations. To fully understand the real value of the electric field excited from the helical line in PLIA, an optical electric integrated electric field measurement system was adopted. The measurement result shows that the real magnitude of axial electric field is smaller than that calculated, probably due to the actual pitch of the resister column which is much less than that of helix. (authors)

  7. Optimized transmission-line impedance transformers for petawatt-class pulsed-power accelerators

    D. R. Welch

    2008-03-01

    Full Text Available We have developed 1D analytic and 2D fully electromagnetic models of radial transmission-line impedance transformers. The models have been used to quantify the power-transport efficiency and pulse sharpening of such transformers as a function of voltage pulse width and impedance profile. For the cases considered, we find that in the limit as Γ→0 (where Γ is the ratio of the pulse width to the one-way transit time of the transformer, the transport efficiency is maximized when the impedance profile is exponential. As Γ increases from zero, the optimum profile gradually deviates from an exponential. A numerical procedure is presented that determines the optimum profile for a given pulse shape and width. The procedure can be applied to optimize the design of impedance transformers used in petawatt-class pulsed-power accelerators.

  8. The curve shortening problem

    Chou, Kai-Seng

    2001-01-01

    Although research in curve shortening flow has been very active for nearly 20 years, the results of those efforts have remained scattered throughout the literature. For the first time, The Curve Shortening Problem collects and illuminates those results in a comprehensive, rigorous, and self-contained account of the fundamental results.The authors present a complete treatment of the Gage-Hamilton theorem, a clear, detailed exposition of Grayson''s convexity theorem, a systematic discussion of invariant solutions, applications to the existence of simple closed geodesics on a surface, and a new, almost convexity theorem for the generalized curve shortening problem.Many questions regarding curve shortening remain outstanding. With its careful exposition and complete guide to the literature, The Curve Shortening Problem provides not only an outstanding starting point for graduate students and new investigations, but a superb reference that presents intriguing new results for those already active in the field.

  9. Propagation of 1-THz bandwidth electrical pulses on high Tc superconducting transmission lines

    Nuss, M.C.; Mankiewich, P.M.; Howard, R.E.; Harvey, T.E.; Brandle, C.D.; Straugh, B.L.; Smith, P.R.

    1989-01-01

    The new high temperature superconductors have triggered enormous interest not only because of the unique physics involved but also because of their technical potentials, such as the promise for propagation of extremely short electrical pulses. Superconducting band caps of --20TH z are predicted assuming BCS theory for the superconductor, making lossless propagation of electrical pulses as short as 50 fs possible. Despite microwave measurements at low frequencies of several gigahertz first studies at higher frequencies by Dykaar et al have shown distortion-free propagation of 100-GHz electrical pulses on YBa 2 Cu 3 O 3 (YBCO) lines for --5-mm propagation distance. Results were also reported for aluminum coplanar lines and a YBCO ground plane. The authors report on the propagation of 1-ps electrical pulses (1-THz bandwidth) on YBCO coplanar transmission lines defined on lanthanum gallate (LaGaO 3 ) as a substrate. On LaGaO 3 , YBCO grows highly oriented as on SrTiO 3 . However, unlike SrTiO 3 , LaGaO 3 has a much lower dielectric constant and small losses in the terahertz frequency range. Electrical pulses of --750-fs duration are generated in a radiation-damaged silicon-on-sapphire photoconductive switch integrated into a 20-μm coplanar stripline with 10-μm spacing and excited with 100-fs optical pulses from a CPM laser. An μ1-THz bandwidth electrical contact is made to the YBCO coplanar stripline defined on LaGaO 3 using a flip-chip geometry. They find that electrical pulses broaden only from 750 fs to 1 ps with little loss in amplitude on traveling through their flip-chip input and propagated electrical pulses are probed by electooptic sampling in two small LiTaO 3 crystals separated by 3 mm

  10. High temperature superconducting Josephson transmission lines for pulse and step sharpening

    Martens, J.S.; Wendt, J.R.; Hietala, V.M.; Ginley, D.S.; Ashby, C.I.H.; Plut, T.A.; Vawter, G.A.; Tigges, C.P.; Siegal, M.P.; Hou, S.Y.; Phillips, J.M.; Hohenwarter, G.K.G.

    1992-01-01

    An increasing number of high speed digital and other circuit applications require very narrow impulses or rapid pulse edge transitions. Shock wave transmission lines using series or shunt Josephson junctions are one way to generate these signals. Using two different high temperature superconducting Josephson junction processes (step-edge and electron beam defined nanobridges), such transmission lines have been constructed and tested at 77 K. Shock wave lines with approximately 60 YBaCuO nanobridges, have generated steps with fall times of about 10 ps. With step-edge junctions (with higher figures of merit but lower uniformity), step transition times have been reduced to an estimated 1 ps

  11. Prophylactic first-line antibiotics reduce infectious fever and shorten hospital stay during chemotherapy-induced agranulocytosis in childhood acute myeloid leukemia.

    Feng, Xiaoqin; Ruan, Yongsheng; He, Yuelin; Zhang, Yuming; Wu, Xuedong; Liu, Huayin; Liu, Xuan; He, Lan; Li, Chunfu

    2014-01-01

    There exists few pediatric data on the safety and efficacy of prophylactic antibiotics during chemotherapy-induced agranulocytosis. We prospectively studied the incidence of infection-related fever in 38 children, aged 2-16 years, with acute myeloid leukemia (AML) over 121 chemotherapy treatment cycles. A prophylactic group (n = 18) was given either vancomycin/cefepime (400 mg/m(2), q12 h/50 mg/kg, q12 h) or piperacillin/tazobactam (110 mg/kg, q12 h). Control patients (n = 20) received no preventive antibiotics. The prophylactic group (59 treatment cycles) experienced fever less frequently than the control group (0.4 vs. 0.9 events; p chemotherapy-induced agranulocytosis can effectively reduce the incidence of infectious fever and can shorten the average length of hospital stay, improving treatment success and quality of life. © 2014 S. Karger AG, Basel.

  12. Effects of dispersion on electromagnetic parameters of tape-helix Blumlein pulse forming line of accelerator

    Zhang, Y.; Liu, J.L.; Feng, J.H.

    2012-01-01

    In this paper, the tape-helix model is introduced in the field of intense electron beam accelerator to analyze the dispersion effects on the electromagnetic parameters of helical Blumlein pulse forming line (PFL). Work band and dispersion relation of the PFL are analyzed, and the normalized coefficients of spatial harmonics are calculated. Dispersion effects on the important electromagnetic parameters of PFL, such as phase velocity, slow-wave coefficient, electric length and pulse duration, are analyzed as the central topic. In the PFL, electromagnetic waves with different frequencies in the work band of PFL have almost the same phase velocity. When de-ionized water, transformer oil and air are used as the PFL filling dielectric, respectively, the pulse duration of the helical Blumlein PFL is calculated as 479.6 ns, 81.1 ns and 53.1 ns in order. Electromagnetic wave simulation and experiments are carried out to demonstrate the theoretical calculations of the electric length and pulse duration which directly describe the phase velocity and dispersion of the PFL. Simulation results prove the theoretical analysis and calculation on pulse duration. Experiment is carried out based on the tape-helix Blumlein PFL and magnetic switch system. Experimental results show that the pulse durations are tested as 460 ns, 79 ns and 49 ns in order when de-ionized water, transformer oil and air are used respectively. Experimental results basically demonstrate the theoretical calculations and the analyses of dispersion. (authors)

  13. NMR imaging of solids with multiple-pulse line narrowing and radiofrequency gradients

    Werner, M.H.

    1993-01-01

    The usual methods of magnetic resonance imaging fail in rigid solids due to the line-shape contributions of dipolar coupling, chemical shift dispersion and anisotropy, and bulk magnetic susceptibility. This dissertation presents a new method of solid-stage imaging by nuclear magnetic resonance which averages away these contributions with multiple-pulse line-narrowing and encodes spatial information with pulsed radiofrequency field gradients. This method is closely related to simultaneously developed methods utilizing pulsed DC gradients, and offers similar improvements in sensitivity and resolution. The advantage of rf gradients is that they can be rapidly switched without inducing eddy currents in the probe or the magnet. In addition, the phases and amplitudes of the rf gradients can be switched by equipment which is already part of an NMR spectrometer capable of solid-state spectroscopy. The line-narrowing and gradient pulses originate in separate rf circuits tuned to the same frequency. Interactions between the circuits have been minimized by a method of active Q-switching which employs PIN diodes in the matching networks of these circuits. Both one- and two-dimensional images are presented. The latter are obtained by a novel method in which the two dimensions of imaging transverse to the static magnetic field are encoded by two orthogonal components of a single rf gradient. A π/2 phase shift of the rf phase relative to that of the line-narrowing pulses selects one component or the other. This arrangement allows the solid-state analogs of versatile imaging sequences based on Fourier imaging and eliminates the need for sample rotation and back-projection methods. Coherent averaging theory is used to analyze this imaging technique and exact numerical simulations on several coupled spins are discussed. These lend insight to the residual linewidth and its dependence on pixel position as well as to the range of applicability of this technique

  14. A coaxial-output capacitor-loaded annular pulse forming line.

    Li, Rui; Li, Yongdong; Su, Jiancang; Yu, Binxiong; Xu, Xiudong; Zhao, Liang; Cheng, Jie; Zeng, Bo

    2018-04-01

    A coaxial-output capacitor-loaded annular pulse forming line (PFL) is developed in order to reduce the flat top fluctuation amplitude of the forming quasi-square pulse and improve the quality of the pulse waveform produced by a Tesla-pulse forming network (PFN) type pulse generator. A single module composed of three involute dual-plate PFNs is designed, with a characteristic impedance of 2.44 Ω, an electrical length of 15 ns, and a sustaining voltage of 60 kV. The three involute dual-plate PFNs connected in parallel have the same impedance and electrical length. Due to the existed small inductance and capacitance per unit length in each involute dual-plate PFN, the upper cut-off frequency of the PFN is increased. As a result, the entire annular PFL has better high-frequency response capability. Meanwhile, the three dual-plate PFNs discharge in parallel, which is much closer to the coaxial output. The series connecting inductance between adjacent two modules is significantly reduced when the annular PFL modules are connected in series. The pulse waveform distortion is reduced when the pulse transfers along the modules. Finally, the shielding electrode structure is applied on both sides of the module. The electromagnetic field is restricted in the module when a single module discharges, and the electromagnetic coupling between the multi-stage annular PFLs is eliminated. Based on the principle of impedance matching between the multi-stage annular PFL and the coaxial PFL, the structural optimization design of a mixed PFL in a Tesla type pulse generator is completed with the transient field-circuit co-simulation method. The multi-stage annular PFL consists of 18 stage annular PFL modules in series, with the characteristic impedance of 44 Ω, the electrical length of 15 ns, and the sustaining voltage of 1 MV. The mixed PFL can generate quasi-square electrical pulses with a pulse width of 43 ns, and the fluctuation ratio of the pulse flat top is less than 8% when the

  15. A coaxial-output capacitor-loaded annular pulse forming line

    Li, Rui; Li, Yongdong; Su, Jiancang; Yu, Binxiong; Xu, Xiudong; Zhao, Liang; Cheng, Jie; Zeng, Bo

    2018-04-01

    A coaxial-output capacitor-loaded annular pulse forming line (PFL) is developed in order to reduce the flat top fluctuation amplitude of the forming quasi-square pulse and improve the quality of the pulse waveform produced by a Tesla-pulse forming network (PFN) type pulse generator. A single module composed of three involute dual-plate PFNs is designed, with a characteristic impedance of 2.44 Ω, an electrical length of 15 ns, and a sustaining voltage of 60 kV. The three involute dual-plate PFNs connected in parallel have the same impedance and electrical length. Due to the existed small inductance and capacitance per unit length in each involute dual-plate PFN, the upper cut-off frequency of the PFN is increased. As a result, the entire annular PFL has better high-frequency response capability. Meanwhile, the three dual-plate PFNs discharge in parallel, which is much closer to the coaxial output. The series connecting inductance between adjacent two modules is significantly reduced when the annular PFL modules are connected in series. The pulse waveform distortion is reduced when the pulse transfers along the modules. Finally, the shielding electrode structure is applied on both sides of the module. The electromagnetic field is restricted in the module when a single module discharges, and the electromagnetic coupling between the multi-stage annular PFLs is eliminated. Based on the principle of impedance matching between the multi-stage annular PFL and the coaxial PFL, the structural optimization design of a mixed PFL in a Tesla type pulse generator is completed with the transient field-circuit co-simulation method. The multi-stage annular PFL consists of 18 stage annular PFL modules in series, with the characteristic impedance of 44 Ω, the electrical length of 15 ns, and the sustaining voltage of 1 MV. The mixed PFL can generate quasi-square electrical pulses with a pulse width of 43 ns, and the fluctuation ratio of the pulse flat top is less than 8% when the

  16. A long-pulse repetitive operation magnetically insulated transmission line oscillator

    Fan, Yu-Wei; Zhong, Hui-Huang; Zhang, Jian-De; Shu, Ting; Liu, Jin Liang

    2014-01-01

    The improved magnetically insulated transmission line oscillator (MILO) is a gigawatt-class L-band high power microwave tube. It has allowed us to generate 3.1 GW pulse of 40 ns duration in the single-pulse operation and 500 MW pulse of 25 ns duration in the repetition rate operation. However, because of the severe impedance mismatch, the power conversion efficiency is only about 4% in the repetition rate operation. In order to eliminate the impedance mismatch and obtain repetitive long-pulse high-power microwave (HPM), a series of experiments are carried out and the recent progress is presented in this paper. In the single-pulse operation, when the diode voltage is 466 kV and current is 41.6 kA, the radiated microwave power is above 2.2 GW, the pulse duration is above 102 ns, the microwave frequency is about 1.74 GHz, and the power conversion efficiency is about 11.5%. In the repetition rate operation, under the condition of the diode voltage about 400 kV, beam current about 38 kA, the radiated microwave power is about 1.0 GW, the pulse duration is about 85 ns. Moreover, the radiated microwave power and the pulse duration decline little by little when the shot numbers increase gradually. The experimental results show that the impedance matching is a vital factor for HPM systems and one of the major technical challenges is to improve the cathode for the repetition rate operation MILO

  17. A long-pulse repetitive operation magnetically insulated transmission line oscillator

    Fan, Yu-Wei; Zhong, Hui-Huang; Zhang, Jian-De; Shu, Ting; Liu, Jin Liang [College of Optoelectric Science and Engineering, National University of Defense Technology, Changsha 410073 (China)

    2014-05-15

    The improved magnetically insulated transmission line oscillator (MILO) is a gigawatt-class L-band high power microwave tube. It has allowed us to generate 3.1 GW pulse of 40 ns duration in the single-pulse operation and 500 MW pulse of 25 ns duration in the repetition rate operation. However, because of the severe impedance mismatch, the power conversion efficiency is only about 4% in the repetition rate operation. In order to eliminate the impedance mismatch and obtain repetitive long-pulse high-power microwave (HPM), a series of experiments are carried out and the recent progress is presented in this paper. In the single-pulse operation, when the diode voltage is 466 kV and current is 41.6 kA, the radiated microwave power is above 2.2 GW, the pulse duration is above 102 ns, the microwave frequency is about 1.74 GHz, and the power conversion efficiency is about 11.5%. In the repetition rate operation, under the condition of the diode voltage about 400 kV, beam current about 38 kA, the radiated microwave power is about 1.0 GW, the pulse duration is about 85 ns. Moreover, the radiated microwave power and the pulse duration decline little by little when the shot numbers increase gradually. The experimental results show that the impedance matching is a vital factor for HPM systems and one of the major technical challenges is to improve the cathode for the repetition rate operation MILO.

  18. A long-pulse repetitive operation magnetically insulated transmission line oscillator.

    Fan, Yu-Wei; Zhong, Hui-Huang; Zhang, Jian-De; Shu, Ting; Liu, Jin Liang

    2014-05-01

    The improved magnetically insulated transmission line oscillator (MILO) is a gigawatt-class L-band high power microwave tube. It has allowed us to generate 3.1 GW pulse of 40 ns duration in the single-pulse operation and 500 MW pulse of 25 ns duration in the repetition rate operation. However, because of the severe impedance mismatch, the power conversion efficiency is only about 4% in the repetition rate operation. In order to eliminate the impedance mismatch and obtain repetitive long-pulse high-power microwave (HPM), a series of experiments are carried out and the recent progress is presented in this paper. In the single-pulse operation, when the diode voltage is 466 kV and current is 41.6 kA, the radiated microwave power is above 2.2 GW, the pulse duration is above 102 ns, the microwave frequency is about 1.74 GHz, and the power conversion efficiency is about 11.5%. In the repetition rate operation, under the condition of the diode voltage about 400 kV, beam current about 38 kA, the radiated microwave power is about 1.0 GW, the pulse duration is about 85 ns. Moreover, the radiated microwave power and the pulse duration decline little by little when the shot numbers increase gradually. The experimental results show that the impedance matching is a vital factor for HPM systems and one of the major technical challenges is to improve the cathode for the repetition rate operation MILO.

  19. The effects of lightning and high altitude electromagnetic pulse on power distribution lines

    Uman, M.A.; Rubinstein, M.; Yacoub, Z. [Florida Univ., Gainesville, FL (United States)

    1995-01-01

    We simultaneously recorded the voltages induced by lightning on both ends of an unenergized 448-meter long unenergized electric power line and the lightning vertical electric and horizontal magnetic fields at ground level near the line. The lightning data studied and presented here were due both to cloud lightning and to very close (about 20 m from the line) artificially initiated lightning. For cloud sources, a frequency-domain computer program called EMPLIN was used to calculate induced line voltages as a function of source elevation, angle of incidence, and wave polarization of the radiated cloud discharge pulses in order to compare with the measurements. For very-close lightning, the measured line voltages could be grouped into two categories, those in which multiple, similarly shaped, evenly spaced pulses were observed, which we call oscillatory, and those dominated by a principal pulse with subsidiary oscillations of much smaller amplitude, which we call impulsive. The amplitude of the induced voltage ranged from tens of kilovolts for oscillatory voltages to hundreds of kilovolts for impulsive voltages. A new technique is derived for the calculation of the electromagnetic fields from nearby lightning to ground above an imperfectly conducting ground. This technique was used in conjunction with an existing time domain coupling theory and lightning return stroke model to calculate voltages at either end of the line. The results show fair agreement with the measured oscillatory voltage waveforms if corona is ignored and improved results when corona effects are modeled. The modeling of the impulsive voltage, for which local flashover probably successful. In an attempt to understand better the sources of the line voltages for very close lightning, measurements of the horizontal and vertical electric fields 30 m from triggered lightning were obtained.

  20. Preliminary study of steep pulse irreversible electroporation technology in human large cell lung cancer cell lines L9981

    Song Zuoqing

    2013-01-01

    Full Text Available Our aim was to validate the effectiveness of steep pulse irreversible electroporation technology in human large cell lung cancer cells and to screen the optimal treatment of parameters for human large cell lung cancer cells. Three different sets of steep pulse therapy parameters were applied on the lung cancer cell line L9981. The cell line L9981 inhibition rate and proliferation capacity were detected by Vi-Cell vitality analysis and MTT. Steep pulsed irreversible electroporation technology for large cell lung cancer L9981 presents killing effects with various therapy parameters. The optimal treatment parameters are at a voltage amplitude of 2000V/cm, pulse width of 100μs, pulse frequency of 1 Hz, pulse number 10. With this group of parameters, steep pulse could have the best tumor cell-killing effects.

  1. Schemes of high-power pulsed generators with inductive storages on stepped lines

    Gordeev, V.S.; Bossamykin, V.S.

    1996-01-01

    Some multistage pulse generator designs based on homogeneous transmission lines of equal electrical length T 0 with stepwise impedance changes are described. The energy is initially stored as magnetic field by all the generator stages, while it is also stored by some of them as electrical energy. Upon triggering the switch connecting the high-voltage electrode of charged lines to the grounded generator frame, both the magnetic and electrical energies would concentrate completely at the generator output due to wave effects. Ideally, for any number of stages, the resistive load connected in parallel to the current opening switch is where a square-shaped voltage pulse of 2T 0 width would be generated, whose peak value can be considerably higher than the generator charging voltage. (author). 1 fig., 5 refs

  2. Schemes of high-power pulsed generators with inductive storages on stepped lines

    Gordeev, V S; Bossamykin, V S [All-Russian Scientific Research Inst. of Experimental Physics, Sarov (Russian Federation)

    1997-12-31

    Some multistage pulse generator designs based on homogeneous transmission lines of equal electrical length T{sub 0} with stepwise impedance changes are described. The energy is initially stored as magnetic field by all the generator stages, while it is also stored by some of them as electrical energy. Upon triggering the switch connecting the high-voltage electrode of charged lines to the grounded generator frame, both the magnetic and electrical energies would concentrate completely at the generator output due to wave effects. Ideally, for any number of stages, the resistive load connected in parallel to the current opening switch is where a square-shaped voltage pulse of 2T{sub 0} width would be generated, whose peak value can be considerably higher than the generator charging voltage. (author). 1 fig., 5 refs.

  3. Adaptive Pulsed Laser Line Extraction for Terrain Reconstruction using a Dynamic Vision Sensor

    Christian eBrandli

    2014-01-01

    Full Text Available Mobile robots need to know the terrain in which they are moving for path planning and obstacle avoidance. This paper proposes the combination of a bio-inspired, redundancy-suppressing dynamic vision sensor with a pulsed line laser to allow fast terrain reconstruction. A stable laser stripe extraction is achieved by exploiting the sensor’s ability to capture the temporal dynamics in a scene. An adaptive temporal filter for the sensor output allows a reliable reconstruction of 3D terrain surfaces. Laser stripe extractions up to pulsing frequencies of 500Hz were achieved using a line laser of 3mW at a distance of 45cm using an event-based algorithm that exploits the sparseness of the sensor output. As a proof of concept, unstructured rapid prototype terrain samples have been successfully reconstructed with an accuracy of 2mm.

  4. Transmission-line-circuit model of an 85-TW, 25-MA pulsed-power accelerator

    B. T. Hutsel; P. A. Corcoran; M. E. Cuneo; M. R. Gomez; M. H. Hess; D. D. Hinshelwood; C. A. Jennings; G. R. Laity; D. C. Lamppa; R. D. McBride; J. K. Moore; A. Myers; D. V. Rose; S. A. Slutz; W. A. Stygar

    2018-01-01

    We have developed a physics-based transmission-line-circuit model of the Z pulsed-power accelerator. The 33-m-diameter Z machine generates a peak electrical power as high as 85 TW, and delivers as much as 25 MA to a physics load. The circuit model is used to design and analyze experiments conducted on Z. The model consists of 36 networks of transmission-line-circuit elements and resistors that represent each of Zs 36 modules. The model of each module includes a Marx generator, intermediate-en...

  5. Active high-power RF pulse compression using optically switched resonant delay lines

    Tantawi, S.G.; Ruth, R.D.; Vlieks, A.E.

    1996-11-01

    The authors present the design and a proof of principle experimental results of an optically controlled high power rf pulse compression system. The design should, in principle, handle few hundreds of Megawatts of power at X-band. The system is based on the switched resonant delay line theory. It employs resonant delay lines as a means of storing rf energy. The coupling to the lines is optimized for maximum energy storage during the charging phase. To discharge the lines, a high power microwave switch increases the coupling to the lines just before the start of the output pulse. The high power microwave switch, required for this system, is realized using optical excitation of an electron-hole plasma layer on the surface of a pure silicon wafer. The switch is designed to operate in the TE 01 mode in a circular waveguide to avoid the edge effects present at the interface between the silicon wafer and the supporting waveguide; thus, enhancing its power handling capability

  6. Transmission line pulse system for avalanche characterization of high power semiconductor devices

    Riccio, Michele; Ascione, Giovanni; De Falco, Giuseppe; Maresca, Luca; De Laurentis, Martina; Irace, Andrea; Breglio, Giovanni

    2013-05-01

    Because of the increasing in power density of electronic devices for medium and high power application, reliabilty of these devices is of great interest. Understanding the avalanche behaviour of a power device has become very important in these last years because it gives an indication of the maximum energy ratings which can be seen as an index of the device ruggedness. A good description of this behaviour is given by the static IV blocking characteristc. In order to avoid self heating, very relevant in high power devices, very short pulses of current have to be used, whose value can change from few milliamps up to tens of amps. The most used method to generate short pulses is the TLP (Transmission Line Pulse) test, which is based on charging the equivalent capacitance of a transmission line to high value of voltage and subsequently discharging it onto a load. This circuit let to obtain very short square pulses but it is mostly used for evaluate the ESD capability of semiconductor and, in this environment, it generates pulses of low amplitude which are not high enough to characterize the avalanche behaviour of high power devices . Advanced TLP circuit able to generate high current are usually very expensive and often suffer of distorption of the output pulse. In this article is proposed a simple, low cost circuit, based on a boosted-TLP configuration, which is capable to produce very square pulses of about one hundreds of nanosecond with amplitude up to some tens of amps. A prototype is implemented which can produce pulses up to 20A of amplitude with 200 ns of duration which can characterize power devices up to 1600V of breakdown voltage. Usage of microcontroller based logic make the circuit very flexible. Results of SPICE simulation are provided, together with experimental results. To prove the effectiveness of the circuit, the I-V blocking characteristics of two commercial devices, namely a 600V PowerMOS and a 1200V Trench-IGBT, are measured at different

  7. On-line statistical processing of radiation detector pulse trains with time-varying count rates

    Apostolopoulos, G.

    2008-01-01

    Statistical analysis is of primary importance for the correct interpretation of nuclear measurements, due to the inherent random nature of radioactive decay processes. This paper discusses the application of statistical signal processing techniques to the random pulse trains generated by radiation detectors. The aims of the presented algorithms are: (i) continuous, on-line estimation of the underlying time-varying count rate θ(t) and its first-order derivative dθ/dt; (ii) detection of abrupt changes in both of these quantities and estimation of their new value after the change point. Maximum-likelihood techniques, based on the Poisson probability distribution, are employed for the on-line estimation of θ and dθ/dt. Detection of abrupt changes is achieved on the basis of the generalized likelihood ratio statistical test. The properties of the proposed algorithms are evaluated by extensive simulations and possible applications for on-line radiation monitoring are discussed

  8. [Apoptosis of human lung carcinoma cell line GLC-82 induced by high power electromagnetic pulse].

    Cao, Xiao-zhe; Zhao, Mei-lan; Wang, De-wen; Dong, Bo

    2002-09-01

    Electromagnetic pulse (EMP) could be used for sterilization of food and the efficiency is higher than 2450 MHz continuous microwave done. This study was designed to evaluate the effect of electromagnetic pulse (EMP) on apoptosis of human lung carcinoma cell line GLC-82, so that to explore and develop therapeutic means for cancer. The injury changes in GLC-82 cells after irradiated with EMP (electric field intensity was 60 kV/m, 5 pulses/2 min) were analyzed by cytometry, MTT chronometry, and flow cytometry. The immunohistochemical SP staining was used to determine the expressions of bcl-2 protein and p53 protein. The stained positive cells were analyzed by CMIAS-II image analysis system at a magnification 400. All data were analyzed by SPSS8.0 software. EMP could obviously inhibited proliferation and activity of lung carcinoma cell line GLC-82. The absorbance value (A570) of MTT decreased immediately, at 0 h, 1 h, and 6 h after the GLC-82 cells irradiated by EMP as compared with control group. The highest apoptosis rate was found to reach 13.38% by flow cytometry at 6 h after EMP irradiation. Down-regulation of bcl-2 expression and up-regulation of p53 expression were induced by EMP. EMP promotes apoptosis of GLC-82 cells. At same time, EMP can down-regulate bcl-2 expression and up-regulate p53 expression in GLC-82 cells. The bcl-2 and the p53 protein may involve the apoptotic process.

  9. A hybrid pulse combining topology utilizing the combination of modularized avalanche transistor Marx circuits, direct pulse adding, and transmission line transformer.

    Li, Jiangtao; Zhao, Zheng; Sun, Yi; Liu, Yuhao; Ren, Ziyuan; He, Jiaxin; Cao, Hui; Zheng, Minjun

    2017-03-01

    Numerous applications driven by pulsed voltage require pulses to be with high amplitude, high repetitive frequency, and narrow width, which could be satisfied by utilizing avalanche transistors. The output improvement is severely limited by power capacities of transistors. Pulse combining is an effective approach to increase the output amplitude while still adopting conventional pulse generating modules. However, there are drawbacks in traditional topologies including the saturation tendency of combining efficiency and waveform oscillation. In this paper, a hybrid pulse combining topology was adopted utilizing the combination of modularized avalanche transistor Marx circuits, direct pulse adding, and transmission line transformer. The factors affecting the combining efficiency were determined including the output time synchronization of Marx circuits, and the quantity and position of magnetic cores. The numbers of the parallel modules and the stages were determined by the output characteristics of each combining method. Experimental results illustrated the ability of generating pulses with 2-14 kV amplitude, 7-11 ns width, and a maximum 10 kHz repetitive rate on a matched 50-300 Ω resistive load. The hybrid topology would be a convinced pulse combining method for similar nanosecond pulse generators based on the solid-state switches.

  10. Error statistics during the propagation of short optical pulses in a high-speed fibreoptic communication line

    Shapiro, E G

    2008-01-01

    Simple analytic expressions are derived to approximate the bit error rate for data transmission through fibreoptic communication lines. The propagation of optical pulses is directly numerically simulated. Analytic estimates are in good agreement with numerical calculations. (fibreoptic communication)

  11. Development of 700 pps high-duty-cycle line-type pulse modulator

    Baba, H.; Satoh, K.; Miura, A. [NIHON KOSHUHA Co., LTD., Yokohama, Kanagawa (Japan)] [and others

    1997-04-01

    The high-duty-cycle line-type pulse modulator has been developed to drive the 5.5 MW S-band klystron at the 700 pps maximum repetition-rate and the 14 {mu}sec flat-top pulse-width. To keep an enough recovery time to the thyratron-tube, the command charging scheme was adopted. To do this, a charging SCR-bank has been developed, which is capable of handling the peak charging current of 50 A. The system achieved the world wide highest average output-power of 205 kW. Two modulators have been installed in a new high-duty-cycle electron linear accelerator, which has been started its business operation in March 1996 as an electron-beam-sterilization facility. (J.P.N)

  12. Four-deep charge-time and pulse-width scaling discriminator for delay line MWPC's

    Lee, K.L.; Kirsten, F.A.; Grigorian, A.; Guiragossian, Z.G.T.

    1976-01-01

    A discriminator has been developed for digitizing both intercepted total charge and location of electromagnetic shower and particle trajectories in multi-wire proportional chambers read by delay lines. Determination of shower trajectory is aided by video signal integration followed by centroid-locating discrimination. Calibrated run-down of the signal integrating capacitor gives the charge information above a given threshold level. The discriminator is designed to handle up to four shower-induced video signals per event by incorporating steering circuits within the module. Each video signal is examined for time over an adjustable threshold. Video pulses with separation of less than 20 nsec are treated as a single pulse. Counter-logic circuits indicate the number of video signals digitized. These signal processing circuits provide a first level of data sifting which otherwise must be carried out with additional discriminator channels and added complexity in data recognition

  13. Modeling particle emission and power flow in pulsed-power driven, nonuniform transmission lines

    Nichelle Bruner

    2008-04-01

    Full Text Available Pulsed-power driven x-ray radiographic systems are being developed to operate at higher power in an effort to increase source brightness and penetration power. Essential to the design of these systems is a thorough understanding of electron power flow in the transmission line that couples the pulsed-power driver to the load. In this paper, analytic theory and fully relativistic particle-in-cell simulations are used to model power flow in several experimental transmission-line geometries fielded on Sandia National Laboratories’ upgraded Radiographic Integrated Test Stand [IEEE Trans. Plasma Sci. 28, 1653 (2000ITPSBD0093-381310.1109/27.901250]. Good agreement with measured electrical currents is demonstrated on a shot-by-shot basis for simulations which include detailed models accounting for space-charge-limited electron emission, surface heating, and stimulated particle emission. Resonant cavity modes related to the transmission-line impedance transitions are also shown to be excited by electron power flow. These modes can drive oscillations in the output power of the system, degrading radiographic resolution.

  14. On-line analysis of bulk materials using pulsed neutron interrogation

    Lebrun, P.; Tourneur, P. Le; Poumarede, B.; Bach, P.; Moeller, H.

    1999-01-01

    On the basis of our joint experience in neutronics for SODERN and in cement plant engineering for KRUPP POLYSIUS, we have developed a new on-line bulk materials analyser for the cement industry. This equipment includes a pulsed neutron generator GENIE 16, some gamma ray and neutron detectors, specially designed electronics with high counting rate, software delivering the mean elemental composition of raw material, and adequate shielding. This material is transported through the equipment on a conveyor belt, the size of which is adapted to the requirements. This paper briefly describes the equipment and some results, as obtained in dynamic test from a demonstrator installed in Germany

  15. On-line analysis of bulk materials using pulsed neutron interrogation

    Lebrun, P.; Tourneur, P. Le; Poumarede, B.; Möller, H.; Bach, P.

    1999-06-01

    On the basis of our joint experience in neutronics for SODERN and in cement plant engineering for KRUPP POLYSIUS, we have developed a new on-line bulk materials analyser for the cement industry. This equipment includes a pulsed neutron generator GENIE 16, some gamma ray and neutron detectors, specially designed electronics with high counting rate, software delivering the mean elemental composition of raw material, and adequate shielding. This material is transported through the equipment on a conveyor belt, the size of which is adapted to the requirements. This paper briefly describes the equipment and some results, as obtained in dynamic test from a demonstrator installed in Germany.

  16. Broad line and pulsed NMR study of molecular motion in furfuryl alcohol resins

    Glowinkowski, S.; Pajak, Z.

    1978-01-01

    Broad line and pulsed nuclear magnetic resonance studies are carried out on a number of furfuryl alcohol resins differentiated by viscosity. Proton NMR spectra and relaxation times T 1 and Tsub(1rho) are measured over a wide temperature range and the results are interpreted in terms of molecular motion. The marked decrease in second moment and existence of high temperature spin-lattice relaxation times minima are presumed to result from rotational motion of polymer chains. The relaxation processes at low temperature are believed to be due to rotational motion of methyl endgroup and paramagnetic centres. (author)

  17. Anomalous intensities of Ne-like ion resonance line in plasma produced by picosecond laser pulse

    Bryunetkin, B.A.; Skobelev, I.Yu.; Faenov, A.Ya.; Kalashnikov, M.P.; Nikles, P.; Shnyupep, M.

    1995-01-01

    An anomalous structure of intensities of spectral lines of CuXX and GeXXX Ne-like ions emitted by plasma produced by laser pulses of picosecond duration and up to 2x10 18 W/cm 2 flux density is recorded for the first time. It is shown that spectrum maximum of these ions is emitted from a plasma region whose density is significantly above the critical value of the length of heating laser radiation wave. 9 refs.; 3 figs

  18. Development of an x-ray klystron modulator with a pulse-forming line and magnetic switch

    Akemoto, M.; Takeda, S.

    1992-01-01

    A new type of klystron modulator has been developed for the Japan Linear Collider. It consists of a pulse-forming line (PFL), a pulse transformer and a magnetic switch. In order to realize a compact modulator, a triplate strip transmission line using deionized water as a dielectric was adapted. An Fe amorphous core was used for the magnetic switch and the pulse transformer to reduce the size and cost. A preliminary test has shown that an output pulse with a peak voltage of 550 kV, a pulse length (flat-top) of 440 ns and a rise time of 165 ns can be generated for a dummy load with an impedance of 412Ω. It was also experimentally confirmed that the power efficiency of the modulator is approximately 83%. (Author) 7 figs., 3 tabs., 2 refs

  19. Effects of Pulsed Electromagnetic Field on Differentiation of HUES-17 Human Embryonic Stem Cell Line

    Yi-Lin Wu

    2014-08-01

    Full Text Available Electromagnetic fields are considered to potentially affect embryonic development, but the mechanism is still unknown. In this study, human embryonic stem cell (hESC line HUES-17 was applied to explore the mechanism of exposure on embryonic development to pulsed electromagnetic field (PEMF for 400 pulses at different electric field intensities and the differentiation of HUES-17 cells was observed after PEMF exposure. The expression of alkaline phosphatase (AP, stage-specific embryonic antigen-3 (SSEA-3, SSEA-4 and the mRNA level and protein level of Oct4, Sox2 and Nanog in HUES-17 cells remained unchanged after PEMF exposure at the electric field intensities of 50, 100, 200 or 400 kV/m. Four hundred pulses PEMF exposure at the electric field intensities of 50, 100, 200 or 400 kV/m did not affect the differentiation of HUES-17 cells. The reason why electromagnetic fields affect embryonic development may be due to other mechanisms rather than affecting the differentiation of embryonic stem cells.

  20. A novel structure of transmission line pulse transformer with mutually coupled windings.

    Yu, Binxiong; Su, Jiancang; Li, Rui; Zhao, Liang; Zhang, Xibo; Wang, Junjie

    2014-03-01

    A novel structure of transmission line transformer (TLT) with mutually coupled windings is described in this paper. All transmission lines except the first stage of the transformer are wound on a common ferrite core for the TLT with this structure. A referral method was introduced to analyze the TLT with this structure, and an analytic expression of the step response was derived. It is shown that a TLT with this structure has a significantly slower droop rate than a TLT with other winding structures and the number of ferrite cores needed is largely reduced. A four-stage TLT with this structure was developed, whose input and output impedance were 4.2 Ω and 67.7 Ω, respectively. A frequency response test of the TLT was carried out. The test results showed that pulse response time of the TLT is several nanoseconds. The TLT described in this paper has the potential to be used as a rectangle pulse transformer with very fast response time.

  1. Transmission-line-circuit model of an 85-TW, 25-MA pulsed-power accelerator

    Hutsel, B. T.; Corcoran, P. A.; Cuneo, M. E.; Gomez, M. R.; Hess, M. H.; Hinshelwood, D. D.; Jennings, C. A.; Laity, G. R.; Lamppa, D. C.; McBride, R. D.; Moore, J. K.; Myers, A.; Rose, D. V.; Slutz, S. A.; Stygar, W. A.; Waisman, E. M.; Welch, D. R.; Whitney, B. A.

    2018-03-01

    We have developed a physics-based transmission-line-circuit model of the Z pulsed-power accelerator. The 33-m-diameter Z machine generates a peak electrical power as high as 85 TW, and delivers as much as 25 MA to a physics load. The circuit model is used to design and analyze experiments conducted on Z. The model consists of 36 networks of transmission-line-circuit elements and resistors that represent each of Zs 36 modules. The model of each module includes a Marx generator, intermediate-energy-storage capacitor, laser-triggered gas switch, pulse-forming line, self-break water switches, and tri-plate transmission lines. The circuit model also includes elements that represent Zs water convolute, vacuum insulator stack, four parallel outer magnetically insulated vacuum transmission lines (MITLs), double-post-hole vacuum convolute, inner vacuum MITL, and physics load. Within the vacuum-transmission-line system the model conducts analytic calculations of current loss. To calculate the loss, the model simulates the following processes: (i) electron emission from MITL cathode surfaces wherever an electric-field threshold has been exceeded; (ii) electron loss in the MITLs before magnetic insulation has been established; (iii) flow of electrons emitted by the outer-MITL cathodes after insulation has been established; (iv) closure of MITL anode-cathode (AK) gaps due to expansion of cathode plasma; (v) energy loss to MITL conductors operated at high lineal current densities; (vi) heating of MITL-anode surfaces due to conduction current and deposition of electron kinetic energy; (vii) negative-space-charge-enhanced ion emission from MITL anode surfaces wherever an anode-surface-temperature threshold has been exceeded; and (viii) closure of MITL AK gaps due to expansion of anode plasma. The circuit model is expected to be most accurate when the fractional current loss is small. We have performed circuit simulations of 52 Z experiments conducted with a variety of accelerator

  2. Transmission-line-circuit model of an 85-TW, 25-MA pulsed-power accelerator

    B. T. Hutsel

    2018-03-01

    Full Text Available We have developed a physics-based transmission-line-circuit model of the Z pulsed-power accelerator. The 33-m-diameter Z machine generates a peak electrical power as high as 85 TW, and delivers as much as 25 MA to a physics load. The circuit model is used to design and analyze experiments conducted on Z. The model consists of 36 networks of transmission-line-circuit elements and resistors that represent each of Zs 36 modules. The model of each module includes a Marx generator, intermediate-energy-storage capacitor, laser-triggered gas switch, pulse-forming line, self-break water switches, and tri-plate transmission lines. The circuit model also includes elements that represent Zs water convolute, vacuum insulator stack, four parallel outer magnetically insulated vacuum transmission lines (MITLs, double-post-hole vacuum convolute, inner vacuum MITL, and physics load. Within the vacuum-transmission-line system the model conducts analytic calculations of current loss. To calculate the loss, the model simulates the following processes: (i electron emission from MITL cathode surfaces wherever an electric-field threshold has been exceeded; (ii electron loss in the MITLs before magnetic insulation has been established; (iii flow of electrons emitted by the outer-MITL cathodes after insulation has been established; (iv closure of MITL anode-cathode (AK gaps due to expansion of cathode plasma; (v energy loss to MITL conductors operated at high lineal current densities; (vi heating of MITL-anode surfaces due to conduction current and deposition of electron kinetic energy; (vii negative-space-charge-enhanced ion emission from MITL anode surfaces wherever an anode-surface-temperature threshold has been exceeded; and (viii closure of MITL AK gaps due to expansion of anode plasma. The circuit model is expected to be most accurate when the fractional current loss is small. We have performed circuit simulations of 52 Z experiments conducted with a

  3. Simulation Analysis of Transmission-Line Impedance Transformers for Petawatt-Class Pulsed Power Accelerators

    Hu Yixiang; Qiu Aici; Sun Fengju; Huang Tao; Cong Peitian; Wang Liangping; Zeng Jiangtao; Li Yan; Zhang Xinjun; Lei Tianshi

    2011-01-01

    Based on the transmission line code TLCODE, a 1D circuit model for a transmission-line impedance transformer was developed and the simulation results were compared with those in the literature. The model was used to quantify the efficiencies of voltage-transport, energy-transport and power-transport for a transmission-line impedance transformer as functions of ψ (the ratio of the output impedance to the input impedance of the transformer) and Γ (the ratio of the pulse width to the one-way transit time of the transformer) under a large scale of m (the coefficient of the generalized exponential impedance profile). Simulation results suggest that with the increase in Γ, from 0 to ∞, the power transport efficiency first increases and then decreases. The maximum power transport efficiency can reach 90% or even higher for an exponential impedance profile (m = 1). With a consideration of dissipative loss in the dielectric and electrodes of the transformer, two representative designs of the water-insulated transformer are investigated for the next generation of petawatt-class z-pinch drivers. It is found that the dissipative losses in the electrodes are negligibly small, below 0.1%, but the dissipative loss in the water dielectric is about 1% to 4%. (fusion engineering)

  4. Losses at magnetic nulls in pulsed-power transmission line systems

    Mendel, C.W. Jr.; Pointon, T.D.; Savage, M.E.; Seidel, D.B.; Magne, I.; Vezinet, R.

    2006-01-01

    Pulsed-power systems operating in the terawatt regime must deal with large electron flows in vacuum transmission lines. In most parts of these transmission lines the electrons are constrained by the self-magnetic field to flow parallel to the conductors. In very low impedance systems, such as those used to drive Z-pinch radiation sources, the currents from multiple transmission lines are added together. This addition necessarily involves magnetic nulls that connect the positive and negative electrodes. The resultant local loss of magnetic insulation results in electron losses at the anode in the vicinity of the nulls. The lost current due to the magnetic null might or might not be appreciable. In some cases the lost current due to the null is not large, but is spatially localized, and may create a gas and plasma release from the anode that can lead to an excessive loss, and possibly to catastrophic damage to the hardware. In this paper we describe an analytic model that uses one geometric parameter (aside from straightforward hardware size measurements) that determines the loss to the anode, and the extent of the loss region when the driving source and load are known. The parameter can be calculated in terms of the magnetic field in the region of the null calculated when no electron flow is present. The model is compared to some experimental data, and to simulations of several different hardware geometries, including some cases with multiple nulls, and unbalanced feeds

  5. High power, high brightness electron beam generation in a pulse-line driven pseudospark discharge

    Destler, W.W.; Segalov, Z.; Rodgers, J.; Ramaswamy, K.; Reiser, M.

    1993-01-01

    High brightness (∼10 10 A/m 2 rad 2 ), high power density (∼10 10 W/cm 2 ) electron beams have been generated by the mating of a hollow-cathode discharge device operating in the pseudospark regime to the output of a high power pulse line accelerator. Very small diameter (∼1 mm) electron beams with currents in the range 500--1000 A and energies in the range 150--300 keV have been generated with effective emittances estimated to be at or below 170 mm mrad. Such emittances are comparable to those achieved in conventional electron beam sources at current densities several orders of magnitude lower than those observed in these experiments

  6. Characterization of electron beams generated in a high-voltage pulse-line-driven pseudospark discharge

    Ramaswamy, K.; Destler, W.W.; Segalov, Z.; Rodgers, J.

    1994-01-01

    Emittance and energy measurements have been performed on a high-brightness electron beam (>10 10 A/m 2 rad 2 ) with diameter in the range 1--3 mm and energy in the range 150--170 keV. This electron beam is generated by the mating of a hollow-cathode discharge device operating in the pseudospark regime to the output of a high-power pulse line accelerator. The measured effective emittance lies in the range between 30 and 90 mm mrad and increases with axial distance. Electron energy measurements indicate that the high-energy electrons are generated during the first 20--30 ns of the discharge. Both the emittance and energy experiments were performed at two different ambient argon gas pressures (92 and 152 mtorr). Beam expansion as a function of axial position has also been studied and a lower bound on the beam brightness has been obtained

  7. On-line Monitoring Device for High-voltage Switch Cabinet Partial Discharge Based on Pulse Current Method

    Y Tao, S.; Zhang, X. Z.; Cai, H. W.; Li, P.; Feng, Y.; Zhang, T. C.; Li, J.; Wang, W. S.; Zhang, X. K.

    2017-12-01

    The pulse current method for partial discharge detection is generally applied in type testing and other off-line tests of electrical equipment at delivery. After intensive analysis of the present situation and existing problems of partial discharge detection in switch cabinets, this paper designed the circuit principle and signal extraction method for partial discharge on-line detection based on a high-voltage presence indicating systems (VPIS), established a high voltage switch cabinet partial discharge on-line detection circuit based on the pulse current method, developed background software integrated with real-time monitoring, judging and analyzing functions, carried out a real discharge simulation test on a real-type partial discharge defect simulation platform of a 10KV switch cabinet, and verified the sensitivity and validity of the high-voltage switch cabinet partial discharge on-line monitoring device based on the pulse current method. The study presented in this paper is of great significance for switch cabinet maintenance and theoretical study on pulse current method on-line detection, and has provided a good implementation method for partial discharge on-line monitoring devices for 10KV distribution network equipment.

  8. Does oxidative stress shorten telomeres?

    Boonekamp, Jelle J.; Bauch, Christina; Mulder, Ellis; Verhulst, Simon

    Oxidative stress shortens telomeres in cell culture, but whether oxidative stress explains variation in telomere shortening in vivo at physiological oxidative stress levels is not well known. We therefore tested for correlations between six oxidative stress markers and telomere attrition in nestling

  9. Advanced materials for the optical delay line of frequency pulse modulator on the basis of semiconductor laser

    Abrarov, S.M.

    1999-01-01

    In the paper some materials which can be sued as an optical delay line of the pulse frequency modulator are considered. The structure and the principle are described as a modulator consisting of a laser diode with two Fabry Perot resonators and an optical wave guide providing a feedback loop. The optical wave guide fulfills the function of delay line and links the two resonators. The pulse sequence of the radiation of the semiconductor laser arises due to failure and recovery of optical generation. The pulse frequency modulation can be carried out by the action of electrical tension field on the electro optic martial of the wave guide. The selection of three electro-optic crystals for making of the optical wave guide of the considered modulator is justified. (author)

  10. Study of thermal response of superconducting NbN meander line by using 20 ps pulse laser

    Miki, Shigehito; Fujiwara, Daisuke; Simakage, Hisashi; Kawakami, Akira; Wang Zhen; Satoh, Kazuo; Yotsuya, Tsutomu; Ishida, Takekazu

    2005-01-01

    The thermal response of a superconducting NbN thin-film meander line was studied by irradiating with a 20 ps pulse laser. A 10 nm-thick NbN thin film was prepared by dc magnetron sputtering and then processed to fabricate a 3 μm-wide, 125.5 mm-long meander line. The device was placed in a 4 K refrigerator, and the bias temperature was kept below the critical temperature T c . The end of an optical fiber was fixed at the front of a meander line, which was then directly irradiated by using the 20 ps pulse laser. The output voltage was observed with a digital oscilloscope and a low-noise amplifier. The output signals of the thermal response were clearly observed

  11. Improving the output voltage waveform of an intense electron-beam accelerator based on helical type Blumlein pulse forming line

    Xin-Bing Cheng

    2010-07-01

    Full Text Available The Blumlein pulse forming line (BPFL consisting of an inner coaxial pulse forming line (PFL and an outer coaxial PFL is widely used in the field of pulsed power, especially for intense electron-beam accelerators (IEBA. The output voltage waveform determines the quality and characteristics of the output beam current of the IEBA. Comparing with the conventional BPFL, an IEBA based on a helical type BPFL can increase the duration of the output voltage in the same geometrical volume. However, for the helical type BPFL, the voltage waveform on a matched load may be distorted which influences the electron-beam quality. In this paper, an IEBA based on helical type BPFL is studied theoretically. Based on telegrapher equations of the BPFL, a formula for the output voltage of IEBA is obtained when the transition section is taken into account, where the transition section is between the middle cylinder of BPFL and the load. From the theoretical analysis, it is found that the wave impedance and transit time of the transition section influence considerably the main pulse voltage waveform at the load, a step is formed in front of the main pulse, and a sharp spike is also formed at the end of the main pulse. In order to get a well-shaped square waveform at the load and to improve the electron-beam quality of such an accelerator, the wave impedance of the transition section should be equal to that of the inner PFL of helical type BPFL and the transit time of the transition section should be designed as short as possible. Experiments performed on an IEBA with the helical type BPFL show reasonable agreement with theoretical analysis.

  12. Analysis of behaviour of overhead telecommunications or electric lines illuminated by a nuclear electromagnetic pulse: limitations of use for the transmission line theory

    Scotto, M.; Jecko, B.

    1987-01-01

    The illumination of overhead lines by a nuclear electromagnetic pulse (NEMP) in presence of a perfectly conducting ground gives rise to a scattering problem leading to phenomena both studied here in time and frequency domains. This problem is resolved with the help of an integral equation established in space-time domain and making possible (without approximation) the determination of the time dependence of the current induced on each point of the wire structure. Moreover, the passage in frequency domain allows to express a transfer function defined in one point of the excited line, pointing out its spectral characteristics. Results clearly show the insufficiency of the classic transmission line theory concealing some phenomena which are described here and for which an interpretation is proposed [fr

  13. Contribution to the study of an on line inspection system for pulsed Nd:YAG laser welding operations

    Charton, Stephane

    1999-01-01

    This thesis deals with the study of a on line inspection system for pulsed Nd 3+ :YAG laser welding operations. During a welding operation, laser-material interaction results in the emission of signals (optical, acoustical, electrical, thermal), characteristic of its behavior. On line inspection is based on the hypothesis that the signals evolutions, measured by sensors such as photodiodes, microphones.., may be correlated with the welding defects. Laser weld quality inspection can be done by the machine qualification (before and during welding), and by on line monitoring of the welding operation. The similarity of the signals produced by pulsed lasers (machine or interaction) has led us to develop a specific data acquisition and processing software. Signal processing tools utilization (Fourier and wavelets transforms) in conjunction with classification techniques (stress polytopes), introduces an innovating on line inspection approach. Discriminant parameters determination (signals/defect correlation) becomes thus automatic and non subjective. The developed prototype is not dedicated to the detection of a particular defect because the classification operator is a supervised one and needs a learning phase. lt has been validated on welding defects which are easy to deal with, and then applied to a precise production control at the Nuclear Fabrications and Technology Division of the Valduc Center of the French Atomic Energy Agency. (author) [fr

  14. Time-dependent H-like and He-like Al lines produced by ultra-short pulse laser

    Kato, Takako; Kato, Masatoshi [National Inst. for Fusion Science, Nagoya (Japan); Shepherd, R; Young, B; More, R; Osterheld, Al

    1998-03-01

    We have performed numerical modeling of time-resolved x-ray spectra from thin foil targets heated by the LLNL Ultra-short pulse (USP) laser. The targets were aluminum foils of thickness ranging from 250 A to 1250 A, heated with 120 fsec pulses of 400 nm light from the USP laser. The laser energy was approximately 0.2 Joules, focused to a 3 micron spot size for a peak intensity near 2 x 10{sup 19} W/cm{sup 2}. Ly{alpha} and He{alpha} lines were recorded using a 900 fsec x-ray streak camera. We calculate the effective ionization, recombination and emission rate coefficients including density effects for H-like and He-like aluminum ions using a collisional radiative model. We calculate time-dependent ion abundances using these effective ionization and recombination rate coefficients. The time-dependent electron temperature and density used in the calculation are based on an analytical model for the hydrodynamic expansion of the target foils. During the laser pulse the target is ionized. After the laser heating stops, the plasma begins to recombine. Using the calculated time dependent ion abundances and the effective emission rate coefficients, we calculate the time dependent Ly{alpha} and He{alpha} lines. The calculations reproduce the main qualitative features of the experimental spectra. (author)

  15. High-voltage isolation transformer for sub-nanosecond rise time pulses constructed with annular parallel-strip transmission lines.

    Homma, Akira

    2011-07-01

    A novel annular parallel-strip transmission line was devised to construct high-voltage high-speed pulse isolation transformers. The transmission lines can easily realize stable high-voltage operation and good impedance matching between primary and secondary circuits. The time constant for the step response of the transformer was calculated by introducing a simple low-frequency equivalent circuit model. Results show that the relation between the time constant and low-cut-off frequency of the transformer conforms to the theory of the general first-order linear time-invariant system. Results also show that the test transformer composed of the new transmission lines can transmit about 600 ps rise time pulses across the dc potential difference of more than 150 kV with insertion loss of -2.5 dB. The measured effective time constant of 12 ns agreed exactly with the theoretically predicted value. For practical applications involving the delivery of synchronized trigger signals to a dc high-voltage electron gun station, the transformer described in this paper exhibited advantages over methods using fiber optic cables for the signal transfer system. This transformer has no jitter or breakdown problems that invariably occur in active circuit components.

  16. Passivation of organic light emitting diode anode grid lines by pulsed Joule heating

    Janka, M.; Gierth, R.; Rubingh, J.E.; Abendroth, M.; Eggert, M.; Moet, D.J.D.; Lupo, D.

    2015-01-01

    We report the self-aligned passivation of a current distribution grid for an organic light emitting diode (OLED) anode using a pulsed Joule heating method to align the passivation layer accurately on the metal grid. This method involves passing an electric current through the grid to cure a polymer

  17. Bone shortening of clavicular fractures

    Thorsmark, A H; Muhareb Udby, P; Ban, I

    2017-01-01

    BACKGROUND: The indication for operative treatment of clavicular fractures with bone shortening over 2 cm is much debated. Correct measurement of clavicular length is essential, and reliable measures of clavicular length are therefore highly requested by clinical decision-makers. The aim of this ......BACKGROUND: The indication for operative treatment of clavicular fractures with bone shortening over 2 cm is much debated. Correct measurement of clavicular length is essential, and reliable measures of clavicular length are therefore highly requested by clinical decision-makers. The aim......-fracture bone lengthening that indicated methodological problems. The Hill et al. and Silva et al. methods had high minimal detectable change, making their use unreliable. CONCLUSION: As all three measurement methods had either reliability or methodological issues, we found it likely that differences...

  18. Solving the quasi-static field model of the pulse-line accelerator; relationship to a circuit model

    Friedman, Alex

    2005-01-01

    The Pulse-Line Ion Accelerator (PLIA) is a promising approach to high-gradient acceleration of an ion beam at high line charge density. A recent note by R. J. Briggs suggests that a 'sheath helix' model of such a system can be solved numerically in the quasi-static limit. Such a model captures the correct macroscopic behavior from first principles without the need to time-advance the full Maxwell equations on a grid. This note describes numerical methods that may be used to effect such a solution, and their connection to the circuit model that was described in an earlier note by the author. Fine detail of the fields in the vicinity of the helix wires is not obtained by this approach, but for purposes of beam dynamics simulation such detail is not generally needed

  19. Determination of base-line levels of trace amounts in pulses and spices using neutron activation technique

    Zaidi, J.H.; Arif, M.; Fatima, I.; Qureshi, I.H.

    1993-01-01

    It has been established that essential trace elements are vitally important for biochemical systems, whereas toxic elements if present in relatively higher amounts adversely affect these systems. Trace elements reach the human body mainly through foodstuffs. The different articles contain varying amount of toxic and essential elements. It is therefore necessary to asses the adequacy and safety of the diet by determining the base-line levels of these elements. In continuation of our previous work, some varieties of pulses and spices were analyzed using neutron activation technique. Among the four varieties of pulses lentil (lens esculenta) was found to contain higher amounts of essential elements and lower amounts of toxic elements. The daily intake of essential and toxic elements through pulses was estimated and compared with the suggested values. The estimated intake of essential elements is adequate and that of toxic elements is well below the tolerance limit. In spices cumin and caraway seeds were found to contain relatively higher amounts of essential as well as toxic elements. The studies showed that food spices were additional source of trace element intake. (author)

  20. Pulsed THZ Interrogation of Sofi With Knit Lines in 2D

    Banks, H. T; Gibson, N. L; Winfree, W. P

    2006-01-01

    This paper examines the scattering effect of knit lines and voids in SOFI through simulations of THz interrogation at normal and non-normal angles of incidence and using focused and non-focused single-cycle plane waves...

  1. T2 shortening in childhood moyamoya disease

    Takanashi, J.; Sugita, K.; Tanabe, Y.; Ito, C.; Date, H.; Niimi, H.

    1996-01-01

    We examined T2 shortening in six children with infarcts due to moyamoya disease to clarify whether there are characteristic patterns of T2 shortening in the deep grey and white matter. Profound T2 shortening in the deep grey and white matter was observed in the acute stage of infarct in two cases, which changed to high intensity in the chronic stage; in this stage no T2 shortening was demonstrated in any case. Neither haemorrhagic infarction nor calcification was seen on CT or MRI. There could be longitudinally different T2 shortening patterns between infarcts due to moyamoya disease and other disorders. (orig.). With 2 figs., 1 tab

  2. EXPERIENCES INITIATING SOFTWARE PRODUCT LINE ENGINEERING IN SMALL TEAMS WITH PULSE

    Mærsk-Møller, Hans Martin; Jørgensen, Bo Nørregaard

    2010-01-01

    Small teams of software engineers are represented both in small companies and semi-independent fractions in medium and large companies. Even though some results and experience papers have been published in the context of Small- and Medium-Sized Enterprises (SMEs), there is a lack of experience pa...... an existing methodology, PuLSETM, drew advantages of NetBeans Rich Client Platform, and based the product line on the existing application....

  3. Responses of human normal osteoblast cells and osteoblast-like cell line, MG-63 cells, to pulse electromagnetic field (PEMF

    Suttatip Kamolmatyakul

    2008-01-01

    Full Text Available The objective of this in vitro study is to investigate the effect of pulsed electromagnetic field (PEMF on cellular proliferation and osteocalcin production of osteoblast-like cell line, MG-63 cells, and human normal osteoblast cells (NHOC obtained from surgical bone specimens. The cells were placed in 24-well culture plates in the amount of 3x104 cell/wells with 2 ml αMEM media supplemented with 10% FBS. The experimental plates were placed between a pair of Helmoltz coils powered by a pulse generator (PEMF, 50 Hz, 1.5 mV/cm in the upper compartment of a dual incubator (Forma. The control plates were placed in the lower compartment of the incubator without Helmotz coils. After three days, the cell proliferation was measured by the method modified from Mossman (J. Immunol Methods 1983; 65: 55-63. Other sets of plates were used for osteocalcin production assessment. Media from these sets were collected after 6 days and assessed for osteocalcin production using ELISA kits. The data were analyzed using a one-way analysis of variance (ANOVA. The results showed that MG-63 cells from the experimental group proliferated significantly more than those from the control group (20% increase, p<0.05. No significant difference in osteocalcin production was detected between the two groups. On the other hand, NHOC from the experimental group produced larger amount of osteocalcin (25% increase, p<0.05 and proliferated significantly more than those from the control group (100% increase, p<0.05. In conclusion, PEMF effect on osteoblasts might depend on their cell type of origin. For osteoblast-like cell line, MG-63 cells, PEMF increased proliferation rate but not osteocalcin production of the cells. However, PEMF stimulation effect on human normal osteoblast cells was most likely associated with enhancement of both osteocalcin production and cell proliferation.

  4. Radiobiological responses for two cell lines following continuous low dose-rate (CLDR) and pulsed dose rate (PDR) brachytherapy

    Hanisch, Per Henrik; Furre, Torbjoern; Olsen, Dag Rune; Pettersen, Erik O.

    2007-01-01

    The iso-effective irradiation of continuous low-dose-rate (CLDR) irradiation was compared with that of various schedules of pulsed dose rate (PDR) irradiation for cells of two established human lines, T-47D and NHIK 3025. Complete single-dose response curves were obtained for determination of parameters α and β by fitting of the linear quadratic formula. Sublethal damage repair constants μ and T 1/2 were determined by split-dose recovery experiments. On basis of the acquired parameters of each cell type the relative effectiveness of the two regimens of irradiation (CLDR and PDR) was calculated by use of Fowler's radiobiological model for iso-effect irradiation for repeated fractions of dose delivered at medium dose rates. For both cell types the predicted and observed relative effectiveness was compared at low and high iso-effect levels. The results indicate that the effect of PDR irradiation predicted by Fowler's model is equal to that of CLDR irradiation for both small and large doses with T-47D cells. With NHIK 3025 cells PDR irradiation induces a larger effect than predicted by the model for small doses, while it induces the predicted effect for high doses. The underlying cause of this difference is unclear, but cell-cycle parameters, like G2-accumulation is tested and found to be the same for the two cell lines

  5. Antenna Parts and Waveguide Transmission Line of Short Pulse Radar System Design

    M. E. Golubcov

    2014-01-01

    Full Text Available The main point of this research was работы являлось to create a stand to explore the application of short pulse radio signals in radar. The stand consists of antenna and waveguide elements. Each element out to guarantee operation in X-band with 10 percent working bank and 5 percent instantaneous bandwidth and the power output gotta be 1.5 kW. The form of the antenna beam patten need to be similar to cosecant pattern Side-lobe level need to be less than -25 dB. Background level got to be at least -30 dB. Wave friction, which is radiated from the antenna aperture, got to simultaneous formed in a space.As the most easily realizing variant of such antenna cutting parabolic mirror antenna with offset irradiator was chosen. The irradiator phase centre is shifted from the focal point of the paraboloid to form a cosecant pattern. Method of physical optics is used for the analysis of antennas. Calculating pattern of horn irradiator and mirror antenna which were met the requirements was received. The construction choice was limited by the preproduction possibilities, mass and dimensions. Mirror antenna consists of skeleton framing with mirroring elements which are fixing on it. Mirroring plane is multiplex and consists off rectangular planes made by hydroforming method. Antenna was tested and adjusted at the antenna darkroom after fabricating. The results were meted requirements.Besides the mirror antenna and the horn antenna waveguide elements, waveguide bends and rotating joints were calculated, manufactured and researched. All calculations included the manufacturers tolerances, technological corner R etc. As the construction base of rotating joint coaxial waveguide was chosen. The decision on the one hand: let keep the axial symmetry of excited wave at rotating part of the waveguide, on the other hand there’s no necessary to apply resonant rings, which are plug into dielectric beads for the transition from rotating ring part to

  6. Technique of experimental measurements of the optical thickness of a pulse discharge plasma channel in water on a contour reabsorption lines of hydrogen Hα

    O. A. Fedorovich

    2010-03-01

    Full Text Available In this work the results of development and application of the technique of experimental definition of optical thickness (τ of the pulse discharge plasma channel in water which are based on the distribution of radiation intensities on contour reabsorption lines of hydrogen Ha (656.3 nm are given. Optical thickness of continues spectrum was defined by extrapolation of intensities in far wing of contour reabsorption lines of hydrogen Ha, where t value did not vary any more, and the line smoothly transferred in continuous spectrum. The atomic concentration Na, received on a method of definition of t on a contour reabsorption lines of hydrogen Ha., agreed with calculation obtained from the equation of the plasma state. The recommendations on the correct definition of optical thickness of plasma of pulse discharge in liquids are given.

  7. Two-dimensional electron flow in pulsed power transmission lines and plasma opening switches

    Church, B.W.; Longcope, D.W.; Ng, C.K.; Sudan, R.N.

    1991-01-01

    The operation of magnetically insulated transmission lines (MITL) and the interruption of current in a plasma opening switch (POS) are determined by the physics of the electrons emitted by the cathode surface. A mathematical model describes the self-consistent two-dimensional flow of an electron fluid. A finite element code, FERUS, has been developed to solve the two equations which describe Poisson's and Ampere's law in two dimensions. The solutions from this code are obtained for parameters where the electron orbits are considerably modified by the self-magnetic field of the current. Next, the self-insulated electron flow in a MITL with a step change in cross-section is studied using a conventional two-dimensional fully electromagnetic particle-in-cell code, MASK. The equations governing two-dimensional quasi-static electron flow are solved numerically by a third technique which is suitable for predicting current interruption in a POS. The object of the study is to determine the critical load impedance, Z CL , required for current interruption for a given applied voltage, cathode voltage and plasma length. (author). 9 refs, 5 figs

  8. Validation of the design of small diameter pulsed columns for the process line DRA. Tests reliability compared with the industrial scale

    Leybros, J.

    2000-01-01

    As part of the Spin program related to the management of nuclear wastes, studies have been undertaken to develop partitioning processes like Diamex process. The process line CCBP/DRA in Atalante facility forms one of the main equipment devoted to these studies. On this line industrial apparatus are used but some like pulsed columns need to be adapted because of the specificity of the installation: limiting amount of nuclear matter, gaseous waste minimization, safety, limiting amounts of new extractants,... This article presents the comparison of 2 air pulsed columns, one with a standard diameter of 25 (DN25), the other with a reduced diameter of 15 (DN15). This comparison is based on 3 main criteria: pulsation capability, superficial throughput and mass transfer efficiency. The overall comparison shows that a DN15 pulsed column can be considered as a representative tool of research and development. Particularly, the study demonstrates the possibility of scaling up the results

  9. Bit Error Rate Minimizing Channel Shortening Equalizers for Single Carrier Cyclic Prefixed Systems

    Martin, Richard K; Vanbleu, Koen; Ysebaert, Geert

    2007-01-01

    .... Previous work on channel shortening has largely been in the context of digital subscriber lines, a wireline system that allows bit allocation, thus it has focused on maximizing the bit rate for a given bit error rate (BER...

  10. Radiation-induced life shortening. Annex K

    1982-01-01

    The purpose of this Annex is to review the cumulative evidence in the field of non-neoplastic long-term effects of whole-body irradiation. In particular, the existence and extent of life-span shortening in irradiated animals and man, and the relationships of life shortening to the physical and biological variables which may influence this effect of radiation are examined.

  11. Occlusal stability in shortened dental arches.

    Witter, D.J.; Creugers, N.H.J.; Kreulen, C.M.; Haan, A. de

    2001-01-01

    Shortened dental arches consisting of anterior and premolar teeth have been shown to meet oral functional demands. However, the occlusal stability may be at risk as a result of tooth migration. The aim of this nine-year study was to investigate occlusal stability in shortened dental arches as a

  12. High-power, high-brightness pseudospark-produced electron beam driven by improved pulse line accelerator

    Junbino Zhu; Mingchang Wang; Zhijiang Wang

    1995-01-01

    A high power (200KV), intense current density, low emittance (71mmmrad), high brightness (8x10 10 A/m rad) electron beam was generated in the 10cm long, high-voltage-resistive multi-gap hollow cathode pseudospark chamber filled with 15pa nitrogen and driven by an improved pulse line accelerator. The beam was ejected with the 1mm diameter, the 2.2KA beam current, and the 400ns pulse length, and could propagated 20cm in the drift tube. At a distance of 5cm from the anode it penetrated consecutively an acid-sensitive discoloring film and a 0.05mm-thick copper foil both stuck closely, left 0.6mm and 0.3mm holes on them, respectively. That 10 shots on an acid-sensitive film produced a hole of 1.6mm at 7cm downstream of anode showed its good repeatability. After 60 shots the pseudospark discharge chamber was disassembled and observed that almost no destructive damage traces left on the surfaces of its various electrodes and insulators. But on almost all the surfaces of changeable central hole parts installed on intermediate electrodes there are traces of electron emission from the sides facing the anode and of bombardment on the sides facing the cathode, in contrast with which on the front- and back-surfaces of hollow cathode no visible traces of electron emission from then was observed. In addition, there were different tints, strip-like regions on the side of anode facing the cathode. Another interesting phenomenon was that there were a set of concentric circular or elliptical ring pattern on the acid-sensitive discoloring film got at 5cm from the anode and observed tinder a metallograph. It seems that the pseudospark electron beam is Laminar beam i.e, being possessed of a multi-layer structure, at least in the case of multi-gap pseudospark discharge chamber. It was found experimentally that the quality of pseudospark electron beam is much better than that of the cold-cathode electron beam

  13. Pulsed electromagnetic field affects intrinsic and endoplasmatic reticulum apoptosis induction pathways in MonoMac6 cell line culture.

    Kaszuba-Zwoinska, J; Chorobik, P; Juszczak, K; Zaraska, W; Thor, P J

    2012-10-01

    Current studies were aimed to elucidate influence of pulsed electromagnetic field stimulation on cell viability and apoptosis induction pathways. For the experimental model we have chosen monocytic cell line MonoMac6 and several apoptosis inducers with different mechanism of death induction like puromycin, colchicine, cyclophosphamide, minocycline and hydrogen peroxide. MonoMac6 cell line was grown at density 1x10(5) cells/well in 96-well culture plates. To induce cell death cell cultures were treated with different apoptosis inducers like puromycin, colchicine, cyclophosphamide, minocycline, hydrogen peroxide and at the same time with pulsed electromagnetic field 50 Hz, 45±5 mT (PEMF) for 4 hour per each stimulation, three times, in 24 hours intervals. Afterwards, cells were harvested for flow cytometry analysis of cell viability measured by annexin V-APC labeled and propidium iodide staining. Expression of apoptosis related genes was evaluated by semi quantitative reverse transcription (RT)-PCR assay. NuPAGE Novex Western blot analysis was carried out for apoptosis inducing factor (AIF) abundance in cytosolic and nuclear extracts of MonoMac6 cells. Puromycin, colchicine and minocycline activated cells and simultaneously treated with PEMF have shown out diminished percentage of annexinV positive (AnV+) cells comparing to controls without PEMF stimulation. MonaMac6 cells puromycin/colchicyne and PEMF treated were to a higher extent double stained (AnV+,PI+), which means increased late apoptotic as well as necrotic (PI+) cells, than non-stimulated controls. On the other hand, minocycline activated cells prior to PEMF treatment showed diminished amount of apoptotic and necrotic (annexin V, annexin V and propidium iodide, propidium iodide positive staining) cells. The opposite effect of PEMF on the percentage of annexin V positively stained cells has been achieved after treatment of MonoMac6 culture with cyclophoshamide and hydrogen peroxide. PEMF enhanced early

  14. Mathematical Constraints on the Use of Transmission Line Models for Simulating Initial Breakdown Pulses in Lightning Discharges

    da Silva, C. L.; Merrill, R. A.; Pasko, V. P.

    2015-12-01

    A significant portion of the in-cloud lightning development is observed as a series of initial breakdown pulses (IBPs) that are characterized by an abrupt change in the electric field at a remote sensor. Recent experimental and theoretical studies have attributed this process to the stepwise elongation of an initial lightning leader inside the thunderstorm [da Silva and Pasko, JGR, 120, 4989-5009, 2015, and references therein]. Attempts to visually observe these events are hampered due to the fact that clouds are opaque to optical radiation. Due to this reason, throughout the last decade, a number of researchers have used the so-called transmission line models (also commonly referred to as engineering models), widely employed for return stroke simulations, to simulate the waveshapes of IBPs, and also of narrow bipolar events. The transmission line (TL) model approach is to prescribe the source current dynamics in a certain manner to match the measured E-field change waveform, with the purpose of retrieving key information about the source, such as its height, peak current, size, speed of charge motion, etc. Although the TL matching method is not necessarily physics-driven, the estimated source characteristics can give insights on the dominant length- and time-scales, as well as, on the energetics of the source. This contributes to better understanding of the environment where the onset and early stages of lightning development takes place.In the present work, we use numerical modeling to constrain the number of source parameters that can be confidently inferred from the observed far-field IBP waveforms. We compare different modified TL models (i.e., with different attenuation behaviors) to show that they tend to produce similar waveforms in conditions where the channel is short. We also demonstrate that it is impossible to simultaneously retrieve the speed of source current propagation and channel length from an observed IBP waveform, in contrast to what has been

  15. Pulse-forming and line-broadening in AM mode locking of the TEA-CO2laser

    Witteman, W.J.; Olbertz, A.H.M.

    1977-01-01

    The present paper describes AM mode locking for homogeneously broadened systems, a procedure for measuring linewidths under laser conditions, and finally, experimental results for a 1-atm CO2laser. Working in the frequency domain, analytic solutions are given for the pulse bandwidth and pulse shape

  16. SORE - a pulse stretcher for the Saskatchewan 300-MeV linac

    Bergstrom, J.C.; Caplan, H.S.; Norum, B.E.; Servranckx, R.V.

    1983-01-01

    A design study has been made of a pulse stretcher to increase the duty factor of the 300 MeV electron accelerator of the Saskatchewan Accelerator Laboratory. The design was constrained by the desire to house the pulse stretcher within the existing accelerator building and to make maximal use of existing beam transport lines. The pulse stretcher ring consists of two 180 0 bend regions connected by achromatic straight sections. The overall length is 50.49 m and the width is 6.64m. The modes of injection and extraction will be available. In the first mode a shortened linac pulse of 300 ns duration will be injected during a single turn directly into the closed orbit of the pulse stretcher. A second mode of injection/extraction involves use of a longer linac pulse. The basic geometry of the PSR is dictated by the dimensions of the accelerator vault and access room

  17. Occlusal stability in shortened dental arches.

    Witter, D J; Creugers, N H; Kreulen, C M; de Haan, A F

    2001-02-01

    Shortened dental arches consisting of anterior and premolar teeth have been shown to meet oral functional demands. However, the occlusal stability may be at risk as a result of tooth migration. The aim of this nine-year study was to investigate occlusal stability in shortened dental arches as a function over time. Occlusal stability indicators were: 'interdental spacing', 'occlusal contacts of anterior teeth in Intercuspal Position', 'overbite', 'occlusal tooth wear', and 'alveolar bone support'. Subjects with shortened dental arches (n = 74) were compared with subjects with complete dental arches (controls, n = 72). Repeated-measurement regression analyses were applied to assess age-dependent variables in the controls and to relate the occlusal changes to the period of time since the treatment that led to the shortened dental arches. Compared with complete dental arches, shortened dental arches had similar overbite and occlusal tooth wear. They showed more interdental spacing in the premolar regions, more anterior teeth in occlusal contact, and lower alveolar bone scores. Since the differences remained constant over time, we conclude that shortened dental arches can provide long-term occlusal stability. Occlusal changes were self-limiting, indicating a new occlusal equilibrium.

  18. LINES

    Minas Bakalchev

    2015-10-01

    Full Text Available The perception of elements in a system often creates their interdependence, interconditionality, and suppression. The lines from a basic geometrical element have become the model of a reductive world based on isolation according to certain criteria such as function, structure, and social organization. Their traces are experienced in the contemporary world as fragments or ruins of a system of domination of an assumed hierarchical unity. How can one release oneself from such dependence or determinism? How can the lines become less “systematic” and forms more autonomous, and less reductive? How is a form released from modernistic determinism on the new controversial ground? How can these elements or forms of representation become forms of action in the present complex world? In this paper, the meaning of lines through the ideas of Le Corbusier, Leonidov, Picasso, and Hitchcock is presented. Spatial research was made through a series of examples arising from the projects of the architectural studio “Residential Transformations”, which was a backbone for mapping the possibilities ranging from playfulness to exactness, as tactics of transformation in the different contexts of the contemporary world.

  19. Plasma satellites of X-ray spectral lines of ions in a plasma of solid-state targets, heated by a picosecond laser pulse

    Belyaev, V.S.; Vinogradov, V.I.; Kurilov, A.S.; Matafonov, A.P.; Lisitsa, V.S.; Gavrilenko, V.P.; Faenov, A.Ya.; Pikuz, T.A.; Skobelev, I.Yu.; Magunov, A.I.; Pikuz, S.A.

    2003-01-01

    The results of measuring the ions X-ray spectral lines by the interaction of the picosecond laser pulses with the solid-state target are presented. The spectra of the X-ray radiation were observed on the fluorine ion line. The spectral lines satellites, testifying to the availability, are identified. The position of the satellites and the distance between them make it possible to connect them with the intensive electrostatic oscillations with the amplitude, exceeding 10 8 V/cm, and the frequency close to 7 x 10 14 s -1 , substantially lower than the laser wave frequency. The experimental results are compared with the calculated data on the multicharge ions spectra [ru

  20. Frequency Characteristics of Surface Wave Generated by Single-Line Pulsed Laser Beam with Two Kinds of Spatial Energy Profile Models: Gaussian and Square-Like

    Seo, Ho Geon; Kim, Myung Hwan; Choi, Sung Ho; Kim, Chung Seok; Jhang, Kyung Young [Hanyang University, Seoul (Korea, Republic of)

    2012-08-15

    Using a single-line pulsed laser beam is well known as a useful noncontact method to generate a directional surface acoustic wave. In this method, different laser beam energy profiles produce different waveforms and frequency characteristics. In this paper, we considered two typical kinds of laser beam energy profiles, Gaussian and square-like, to find out a difference in the frequency characteristics. To achieve this, mathematical models were proposed first for Gaussian laser beam profile and square-like respectively, both of which depended on the laser beam width. To verify the theoretical models, experimental setups with a cylindrical lens and a line-slit mask were respectively designed to produce a line laser beam with Gaussian spatial energy profile and square-like. The frequency responses of the theoretical models showed good agreement with experimental results in terms of the existence of harmonic frequency components and the shift of the first peak frequencies to low.

  1. Implementation of a neural network for digital pulse shape analysis on a FPGA for on-line identification of heavy ions

    Jimenez, R., E-mail: naharro@uhu.es [Departamento de Ingenieria Eletronica, Sistemas Informaticos y Automatica, Universidad de Huelva, 21071 Huelva (Spain); Sanchez-Raya, M.; Gomez-Galan, J.A. [Departamento de Ingenieria Eletronica, Sistemas Informaticos y Automatica, Universidad de Huelva, 21071 Huelva (Spain); Flores, J.L. [Departamento Ingenieria Electrica y Termica, Universidad de Huelva, 21071 Huelva (Spain); Duenas, J.A.; Martel, I. [Departamento de Fisica Aplicada, Universidad de Huelva, 21071 Huelva (Spain)

    2012-05-11

    Pulse shape analysis techniques for the identification of heavy ions produced in nuclear reactions have been recently proposed as an alternative to energy loss and time of flight methods. However this technique requires a large amount of memory for storing the shapes of charge and current signals. We have implemented a hardware solution for fast on-line processing of the signals producing the relevant information needed for particle identification. Since the pulse shape analysis can be formulated in terms of a pattern recognition problem, a neural network has been implemented in a FPGA device. The design concept has been tested using {sup 12,13}C ions produced in heavy ion reactions. The actual latency of the system is about 20 {mu}s when using a clock frequency of 50 MHz.

  2. A Shortened versus Standard Matched Postpartum Magnesium ...

    Magnesium sulphate is currently the most ideal drug for the treatment of eclampsia but its use in Nigeria is still limited due its cost and clinicians inexperience with the drug. The purpose of this study was to determine whether a shortened postpartum course of magnesium sulphate is as effective as the standard Pritchard ...

  3. On line monitoring of a welding process by pulsed Nd-YAG laser; Controle en ligne d'un procede de soudage par laser Nd-YAG pulse

    Chardon, St.; Voisin, Y.; Gorria, P. [Universite de Bourgogne, Lab. LE2I, 21 - Dijon (France); Vauzelle, Th. [CEA/Valduc, Dept. Fabrications et Technologies Nucleaires, DFTN, 21 - Is-sur-Tille (France)

    1999-07-01

    Laser weld quality inspection can be assured by the machine qualification (before and during welding), and by on line monitoring of the operation. The similarity of the signals produced by pulsed lasers (machine or interaction) leads us to develop a specific data acquisition and processing software. During a welding operation, laser-material interaction results in a characteristically emission of optical, acoustical and electrical signals. These signals are measured by different kinds of sensors (photodiode, microphone, or an electric probe), then recorded and treated with the quoted software. Signal processing tools utilization in conjunction with classification techniques (stress polytopes), introduce an innovating approach of on line inspection. Discriminant parameters determination (signals/defect correlation) become thus automatic and non subjective. (authors)

  4. QCL seeded, ns-pulse, multi-line, CO2 laser oscillator for laser-produced-plasma extreme-UV source

    Nowak, Krzysztof Michał; Suganuma, Takashi; Kurosawa, Yoshiaki; Ohta, Takeshi; Kawasuji, Yasufumi; Nakarai, Hiroaki; Saitou, Takashi; Fujimoto, Junichi; Mizoguchi, Hakaru; Sumitani, Akira; Endo, Akira

    2017-01-01

    Successful merger of state-of-the-art, semiconductor quantum-cascade lasers (QCL), with the mature CO2 laser technology, resulted in a delivery of highly-desired qualities of CO2 laser output that were not available previously without much effort. These qualities, such as multi-line operation, excellent spectro-temporal stability and pulse waveform control, became available from a single device of moderate complexity. This paper describes the operation principle and the unique properties of the solid{state seeded CO2 laser, invented for an application in laser-produced-plasma (LPP), extreme-UV (EUV) light source.

  5. Shortening Scarf osteotomy for correction of severe hallux valgus. Does shortening affect the outcome?

    Karpe, Prasad; Killen, Marie C; Pollock, Raymond D; Limaye, Rajiv

    2016-12-01

    Translation and shortening of Scarf osteotomy allows correction of severe hallux valgus deformity. Shortening may result in transfer metatarsalgia. To evaluate outcome of patients undergoing shortening Scarf osteotomy for severe hallux valgus deformities. Fifteen patients (20feet, mean age 58 years) underwent shortening Scarf osteotomy for severe hallux valgus deformities. Outcomes were pre and postoperative AOFAS scores, IM and HV angles, patient satisfaction. Mean follow-up was 25 months (range 22-30). The IM angle improved from a median of 18.60 (range 13.4-26.20) preoperatively to 9.70 (range 8.0-13.70) postoperatively (8.9; 95% CI=7.6-10.3; phallux valgus deformities with no transfer metatarsalgia. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Design and measurements of a fast high-voltage pulse generator for the MedAustron Low Energy Transfer line fast deflector

    Fowler, T; Mueller, F; Kramer, T; Stadlbauer, T

    2012-01-01

    MedAustron, a centre for ion-therapy and research, will comprise an accelerator facility based on a synchrotron for the delivery of protons and light ions for cancer treatment. The Low Energy Beam Transfer line (LEBT) to the synchrotron contains an electrostatic fast deflector (EFE) which, when energized, deviates the continuous beam arriving from the ion source onto a Faraday Cup: the specified voltage is ±3.5 kV. De-energizing the EFE for variable pulse durations from 500 ns up to d.c. allows beam passage for multi-turn injection into the synchrotron. To maintain beam quality in the synchrotron, the EFE pulse generator requires rise and fall times of less than 300 ns between 90 % of peak voltage and a ±1 V level. To achieve this, a pulsed power supply (PKF), with high voltage MOSFET switches connected in a push-pull configuration, will be mounted in close proximity to the deflector itself. A fast, large dynamic range monitoring circuit will verify switching to the ±1 V level and subsequent flat bottom pu...

  7. Measuring 20-100 T B-fields using Zeeman splitting of sodium emission lines on a 500 kA pulsed power machine

    Banasek, J. T., E-mail: jtb254@cornell.edu; Engelbrecht, J. T.; Pikuz, S. A.; Shelkovenko, T. A.; Hammer, D. A. [Cornell University, Ithaca, New York 14850 (United States)

    2016-11-15

    We have shown that Zeeman splitting of the sodium (Na) D-lines at 5890 and 5896 Å can be used to measure the magnetic field (B-field) produced in high current pulsed power experiments. We have measured the B-field next to a return current conductor in a hybrid X-pinch experiment near a peak current of about 500 kA. Na is deposited on the conductor and then is desorbed and excited by radiation from the hybrid X-pinch. The D-line emission spectrum implies B-fields of about 20 T with a return current post of 4 mm diameter or up to 120 T with a return current wire of 0.455 mm diameter. These measurements were consistent or lower than the expected B-field, thereby showing that basic Zeeman splitting can be used to measure the B-field in a pulsed-power-driven high-energy-density (HED) plasma experiment. We hope to extend these measurement techniques using suitable ionized species to measurements within HED plasmas.

  8. Olanzapine induced Q-Tc shortening.

    Shoja Shafti, Saeed; Fallah Jahromi, Parisa

    2014-12-01

    Prolongation of Q-Tc interval is commonly accepted as a surrogate marker for the ability of a drug to cause torsade de pointes. In the present study, safety of olanzapine versus risperidone was compared among a group of patients with schizophrenia to see the frequency of the electrocardiographic alterations induced by those atypical antipsychotics. Two hundred and sixty-eight female inpatients with schizophrenia entered in one of the two parallel groups to participate in an open study for random assignment to olanzapine (n = 148) or risperidone (n = 120). Standard 12-lead surface electrocardiogram (ECG) was taken from each patient at baseline, before initiation of treatment, and then at the end of management, just before discharge. The parameters that were assessed included heart rate (HR), P-R interval, QRS interval, Q-T interval (corrected = Q-Tc), ventricular activation time (VAT), ST segment, T wave, axis of QRS, and finally, interventricular conduction process. A total of 37.83% of cases in the olanzapine group and 30% in the risperidone group showed some Q-Tc changes; 13.51% and 24.32% of the patients in the olanzapine group showed prolongation and shortening of the Q-Tc, respectively, while changes in the risperidone group were restricted to only prolongation of Q-Tc. Comparison of means showed a significant increment in Q-Tc by risperidone (p = 0.02). Also, comparison of proportions in the olanzapine group showed significantly more cases with shortening of Q-Tc versus its prolongation (p = 0.01). No significant alterations with respect to other variables were evident. Olanzapine and risperidone had comparable potentiality for induction of Q-Tc changes, while production of further miscellaneous alterations in ECG was more observable in the olanzapine group compared with the risperidone group. Also shortening of Q-Tc was specific to olanzapine.

  9. 9 CFR 319.701 - Mixed fat shortening.

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Mixed fat shortening. 319.701 Section... § 319.701 Mixed fat shortening. Shortening prepared with a mixture of meat fats and vegetable oils may... descending order of predominance. ...

  10. Pulsed power

    Anon.

    1977-01-01

    The key element of our pulsed power program is concentration of power in time and space by suppression of breakdown in dielectrics and in vacuum. Magnetically insulated vacuum transmission lines and magnetic suppression of insulator flashover have continued as the main reserch directions. Vacuum insulated line studies at Physics International have been expanded and a test bed at Sandia, called MITE (Magnetically Insulated Transmission Experiment), is under development. The choice for the baseline EBFA design will depend on the outcome of these studies and should be made in July 1977. The slow and intermediate speed pulsed power approaches to EBFA will be based on Proto I and Proto II results and several of the projected EBFA subsystems are presently being tested in Proto II. A further stage of power concentration, within the vacuum diode itself, would considerably ease the burden on dielectrics; methods of power multiplication involving magnetically imploded plasmas are being considered and tests have begun using the Ripple III apparatus

  11. Spine biomechanics associated with the shortened, modern one-plane golf swing.

    Dale, R Barry; Brumitt, Jason

    2016-06-01

    The purpose of this study was to compare kinetic, kinematic, and performance variables associated with full and shortened modern backswings in a skilled group of modern swing (one-plane) golfers. Shortening the modern golf backswing is proposed to reduce vertebral spine stress, but supporting evidence is lacking and performance implications are unknown. Thirteen male golfers performed ten swings of each swing type using their own 7-iron club. Biomechanical-dependent variables included the X-Factor kinematic data and spine kinetics. Performance-related dependent variables included club head velocity (CHV), shot distance, and accuracy (distance from the target line). Data were analysed with repeated measures ANOVA with an a priori alpha of 0.05 (SPSS 22.0, IBM, Armonk, NY, USA). We found significant reductions for the X-Factor (p < 0.05) between the full and shortened swings. The shortened swing condition ameliorated vertebral compression force from 7.6 ± 1.4 to 7.0 ± 1.7 N (normalised to body weight, p = 0.01) and significantly reduced CHV (p < 0.05) by ~2 m/s with concomitant shot distance diminution by ~10 m (p < 0.05). Further research is necessary to examine the applicability of a shortened swing for golfers with low back pain.

  12. Estimating Chlorophyll Fluorescence Parameters Using the Joint Fraunhofer Line Depth and Laser-Induced Saturation Pulse (FLD-LISP Method in Different Plant Species

    Parinaz Rahimzadeh-Bajgiran

    2017-06-01

    Full Text Available A comprehensive evaluation of the recently developed Fraunhofer line depth (FLD and laser-induced saturation pulse (FLD-LISP method was conducted to measure chlorophyll fluorescence (ChlF parameters of the quantum yield of photosystem II (ΦPSII, non-photochemical quenching (NPQ, and the photosystem II-based electron transport rate (ETR in three plant species including paprika (C3 plant, maize (C4 plant, and pachira (C3 plant. First, the relationships between photosynthetic photon flux density (PPFD and ChlF parameters retrieved using FLD-LISP and the pulse amplitude-modulated (PAM methods were analyzed for all three species. Then the relationships between ChlF parameters measured using FLD-LISP and PAM were evaluated for the plants in different growth stages of leaves from mature to aging conditions. The relationships of ChlF parameters/PPFD were similar in both FLD-LISP and PAM methods in all plant species. ΦPSII showed a linear relationship with PPFD in all three species whereas NPQ was found to be linearly related to PPFD in paprika and maize, but not for pachira. The ETR/PPFD relationship was nonlinear with increasing values observed for PPFDs lower than about 800 μmol m−2 s−1 for paprika, lower than about 1200 μmol m−2 s−1 for maize, and lower than about 800 μmol m−2 s−1 for pachira. The ΦPSII, NPQ, and ETR of both the FLD-LISP and PAM methods were very well correlated (R2 = 0.89, RMSE = 0.05, (R2 = 0.86, RMSE = 0.44, and (R2 = 0.88, RMSE = 24.69, respectively, for all plants. Therefore, the FLD-LISP method can be recommended as a robust technique for the estimation of ChlF parameters.

  13. In line digital holography measurement for liquid-liquid flow: application to the characterization of emulsions produced in pulsed column

    Lamadie, F.

    2013-01-01

    Several processes used in research and industry are based on liquid-liquid extraction, a method designed for selective separation of products in a mixture. In liquid-liquid extraction, two immiscible liquids are contacted: an aqueous phase and an organic phase, one of which generally contains an extractant molecule capable of transferring the desired elements to the other phase. The transfer occurs at the contact surface between the two phases. After transfer, both phases are separated by settling. In practice, these operations are performed in industrial apparatus. In order to optimize the operation of these devices, it's important to determine the fundamental characteristics of the emulsion. These include parameters related to the fluid flow velocity as well as parameters related to fluid mixing such as the interfacial area, hold-up, and size distribution of the droplets population. Numerous imaging techniques can be used to measure these parameters. One of them, digital holography, is well-known for allowing complete reconstruction of information about a 3D flow in a single shot. This PhD work deals with a direct application of digital in line holography to droplets rising in a continuous liquid phase. The droplet size imposes a regime of intermediate-field diffraction hardly explored to date. Acquired diffraction patterns show that the usual dark disk model is not valid and that good agreement is obtained with a mixed model coupling thin lens with opaque disk. Hologram focusing is nevertheless performed with a dedicated automated method. A literature review has been conducted to identify the sharpest auto-focus function for our application. In a second step, in order to measure high retention rates, an inverse problem approach is applied on all the outliers and missing droplets. This hologram restitution treatment has been applied to experimental results with a comparison to independent measurements. The main results obtained with calibrated droplets are

  14. Shortening of construction period of nuclear power plant. Activities of construction industry on construction period shortening

    Kamata, Hirofumi

    2011-01-01

    Total construction period could be shorten by prefabricating structures efficiently in another yard and reducing working hours on site, which would reduce work at height or congestion work and also upgrade safety at work. Construction period shortening would surely reduce expenses during work and advance operation start of electric utilities. Construction of reactor building, turbine building, water intake and drainage canal was performed on a relatively large scale and a big share of whole schedule. This article summarized basic technologies to shorten construction period for reactor building/turbine building and water intake and drainage canal. Advanced methods of reactor building/turbine building; (1) modularization of equipment and skeleton, (2) utilization of concrete mold, reinforcing bar and steel frame, (3) precedent steel frame method and (4) steel plate reinforced concrete (SC) method, were outlined and their application examples were shown to reduce work on site and improve work efficiency. As for water intake and drainage canal construction, (1) precast concrete method, (2) SC method and (3) steel plate shell method were described with application examples. Construction procedures and problems using mega block method for water intake and drainage canal were also introduced. (T. Tanaka)

  15. Accelerated Telomere Shortening in Acromegaly; IGF-I Induces Telomere Shortening and Cellular Senescence.

    Matsumoto, Ryusaku; Fukuoka, Hidenori; Iguchi, Genzo; Odake, Yukiko; Yoshida, Kenichi; Bando, Hironori; Suda, Kentaro; Nishizawa, Hitoshi; Takahashi, Michiko; Yamada, Shozo; Ogawa, Wataru; Takahashi, Yutaka

    2015-01-01

    Patients with acromegaly exhibit reduced life expectancy and increased prevalence of age-related diseases, such as diabetes, hypertension, and cardiovascular disease. However, the underlying mechanism has not been fully elucidated. Telomere shortening is reportedly associated with reduced life expectancy and increased prevalence of these age-related diseases. We measured telomere length in patients with acromegaly using quantitative PCR method. The effect of GH and IGF-I on telomere length and cellular senescence was examined in human skin fibroblasts. Patients with acromegaly exhibited shorter telomere length than age-, sex-, smoking-, and diabetes-matched control patients with non-functioning pituitary adenoma (0.62 ± 0.23 vs. 0.75 ± 0.35, respectively, P = 0.047). In addition, telomere length in acromegaly was negatively correlated with the disease duration (R2 = 0.210, P = 0.003). In vitro analysis revealed that not GH but IGF-I induced telomere shortening in human skin fibroblasts. Furthermore, IGF-I-treated cells showed increased senescence-associated β-galactosidase activity and expression of p53 and p21 protein. IGF-I-treated cells reached the Hayflick limit earlier than GH- or vehicle-treated cells, indicating that IGF-I induces cellular senescence. Shortened telomeres in acromegaly and cellular senescence induced by IGF-I can explain, in part, the underlying mechanisms by which acromegaly exhibits an increased morbidity and mortality in association with the excess secretion of IGF-I.

  16. Bipolar pulse generator for intense pulsed ion beam accelerator

    Ito, H.; Igawa, K.; Kitamura, I.; Masugata, K.

    2007-01-01

    A new type of pulsed ion beam accelerator named ''bipolar pulse accelerator'' (BPA) has been proposed in order to improve the purity of intense pulsed ion beams. To confirm the principle of the BPA, we developed a bipolar pulse generator for the bipolar pulse experiment, which consists of a Marx generator and a pulse forming line (PFL) with a rail gap switch on its end. In this article, we report the first experimental result of the bipolar pulse and evaluate the electrical characteristics of the bipolar pulse generator. When the bipolar pulse generator was operated at 70% of the full charge condition of the PFL, the bipolar pulse with the first (-138 kV, 72 ns) and the second pulse (+130 kV, 70 ns) was successfully obtained. The evaluation of the electrical characteristics indicates that the developed generator can produce the bipolar pulse with fast rise time and sharp reversing time

  17. Measurements of line-averaged electron density of pulsed plasmas using a He-Ne laser interferometer in a magnetized coaxial plasma gun device

    Iwamoto, D.; Sakuma, I.; Kitagawa, Y.; Kikuchi, Y.; Fukumoto, N.; Nagata, M.

    2012-10-01

    In next step of fusion devices such as ITER, lifetime of plasma-facing materials (PFMs) is strongly affected by transient heat and particle loads during type I edge localized modes (ELMs) and disruption. To clarify damage characteristics of the PFMs, transient heat and particle loads have been simulated by using a plasma gun device. We have performed simulation experiments by using a magnetized coaxial plasma gun (MCPG) device at University of Hyogo. The line-averaged electron density measured by a He-Ne interferometer is 2x10^21 m-3 in a drift tube. The plasma velocity measured by a time of flight technique and ion Doppler spectrometer was 70 km/s, corresponding to the ion energy of 100 eV for helium. Thus, the ion flux density is 1.4x10^26 m-2s-1. On the other hand, the MCPG is connected to a target chamber for material irradiation experiments. It is important to measure plasma parameters in front of target materials in the target chamber. In particular, a vapor cloud layer in front of the target material produced by the pulsed plasma irradiation has to be characterized in order to understand surface damage of PFMs under ELM-like plasma bombardment. In the conference, preliminary results of application of the He-Ne laser interferometer for the above experiment will be shown.

  18. Immune Response Generated With the Administration of Autologous Dendritic Cells Pulsed With an Allogenic Tumoral Cell-Lines Lysate in Patients With Newly Diagnosed Diffuse Intrinsic Pontine Glioma

    Daniel Benitez-Ribas

    2018-04-01

    Full Text Available Background and objectiveDiffuse intrinsic pontine glioma (DIPG is a lethal brainstem tumor in children. Dendritic cells (DCs have T-cell stimulatory capacity and, therefore, potential antitumor activity for disease control. DCs vaccines have been shown to reactivate tumor-specific T cells in both clinical and preclinical settings. We designed a phase Ib immunotherapy (IT clinical trial with the use of autologous dendritic cells (ADCs pulsed with an allogeneic tumors cell-lines lysate in patients with newly diagnosed DIPG after irradiation (radiation therapy.MethodsNine patients with newly diagnosed DIPG met enrollment criteria. Autologous dendritic cell vaccines (ADCV were prepared from monocytes obtained by leukapheresis. Five ADCV doses were administered intradermally during induction phase. In the absence of tumor progression, patients received three boosts of tumor lysate every 3 months during the maintenance phase.ResultsVaccine fabrication was feasible in all patients included in the study. Non-specific KLH (9/9 patients and specific (8/9 patients antitumor response was identified by immunologic studies in peripheral blood mononuclear cells (PBMC. Immunological responses were also confirmed in the T lymphocytes isolated from the cerebrospinal fluid (CSF of two patients. Vaccine administration resulted safe in all patients treated with this schema.ConclusionThese preliminary results demonstrate that ADCV preparation is feasible, safe, and generate a DIPG-specific immune response detected in PBMC and CSF. This strategy shows a promising backbone for future schemas of combination IT.

  19. Optimal shortening of uniform covering arrays.

    Jose Torres-Jimenez

    Full Text Available Software test suites based on the concept of interaction testing are very useful for testing software components in an economical way. Test suites of this kind may be created using mathematical objects called covering arrays. A covering array, denoted by CA(N; t, k, v, is an N × k array over [Formula: see text] with the property that every N × t sub-array covers all t-tuples of [Formula: see text] at least once. Covering arrays can be used to test systems in which failures occur as a result of interactions among components or subsystems. They are often used in areas such as hardware Trojan detection, software testing, and network design. Because system testing is expensive, it is critical to reduce the amount of testing required. This paper addresses the Optimal Shortening of Covering ARrays (OSCAR problem, an optimization problem whose objective is to construct, from an existing covering array matrix of uniform level, an array with dimensions of (N - δ × (k - Δ such that the number of missing t-tuples is minimized. Two applications of the OSCAR problem are (a to produce smaller covering arrays from larger ones and (b to obtain quasi-covering arrays (covering arrays in which the number of missing t-tuples is small to be used as input to a meta-heuristic algorithm that produces covering arrays. In addition, it is proven that the OSCAR problem is NP-complete, and twelve different algorithms are proposed to solve it. An experiment was performed on 62 problem instances, and the results demonstrate the effectiveness of solving the OSCAR problem to facilitate the construction of new covering arrays.

  20. Two-photon stimulated emission and pulse amplification

    Yuen, H.P.

    1975-01-01

    Threshold conditions are given for the sustained operation of standing-wave and long-pulse traveling-wave two-photon lasers. Pulse shortening in long-pulse two-photon amplification, a behavior absent in the one-photon case, is also demonstrated analytically. (U.S.)

  1. Efficiency Enhancement in DC Pulsed Gas Discharge Memory Panel

    Okamoto, Yukio

    1983-01-01

    Much improvement in the luminous efficiency of a dc pulsed gas discharge memory panel for color TV display was achieved by shortening the sustaining pulse duration. High energy electrons can thus be produced in the pulsed discharge with fast rise times. Calculated optimum value of E/P in a Xe gas discharge is 7-8 V/cm\\cdotTorr.

  2. Accelerated Telomere Shortening in Acromegaly; IGF-I Induces Telomere Shortening and Cellular Senescence

    Matsumoto, Ryusaku; Fukuoka, Hidenori; Iguchi, Genzo; Odake, Yukiko; Yoshida, Kenichi; Bando, Hironori; Suda, Kentaro; Nishizawa, Hitoshi; Takahashi, Michiko; Yamada, Shozo; Ogawa, Wataru; Takahashi, Yutaka

    2015-01-01

    Objective Patients with acromegaly exhibit reduced life expectancy and increased prevalence of age-related diseases, such as diabetes, hypertension, and cardiovascular disease. However, the underlying mechanism has not been fully elucidated. Telomere shortening is reportedly associated with reduced life expectancy and increased prevalence of these age-related diseases. Methods We measured telomere length in patients with acromegaly using quantitative PCR method. The effect of GH and IGF-I on telomere length and cellular senescence was examined in human skin fibroblasts. Results Patients with acromegaly exhibited shorter telomere length than age-, sex-, smoking-, and diabetes-matched control patients with non-functioning pituitary adenoma (0.62 ± 0.23 vs. 0.75 ± 0.35, respectively, P = 0.047). In addition, telomere length in acromegaly was negatively correlated with the disease duration (R 2 = 0.210, P = 0.003). In vitro analysis revealed that not GH but IGF-I induced telomere shortening in human skin fibroblasts. Furthermore, IGF-I-treated cells showed increased senescence-associated β-galactosidase activity and expression of p53 and p21 protein. IGF-I-treated cells reached the Hayflick limit earlier than GH- or vehicle-treated cells, indicating that IGF-I induces cellular senescence. Conclusion Shortened telomeres in acromegaly and cellular senescence induced by IGF-I can explain, in part, the underlying mechanisms by which acromegaly exhibits an increased morbidity and mortality in association with the excess secretion of IGF-I. PMID:26448623

  3. Accelerated Telomere Shortening in Acromegaly; IGF-I Induces Telomere Shortening and Cellular Senescence.

    Ryusaku Matsumoto

    Full Text Available Patients with acromegaly exhibit reduced life expectancy and increased prevalence of age-related diseases, such as diabetes, hypertension, and cardiovascular disease. However, the underlying mechanism has not been fully elucidated. Telomere shortening is reportedly associated with reduced life expectancy and increased prevalence of these age-related diseases.We measured telomere length in patients with acromegaly using quantitative PCR method. The effect of GH and IGF-I on telomere length and cellular senescence was examined in human skin fibroblasts.Patients with acromegaly exhibited shorter telomere length than age-, sex-, smoking-, and diabetes-matched control patients with non-functioning pituitary adenoma (0.62 ± 0.23 vs. 0.75 ± 0.35, respectively, P = 0.047. In addition, telomere length in acromegaly was negatively correlated with the disease duration (R2 = 0.210, P = 0.003. In vitro analysis revealed that not GH but IGF-I induced telomere shortening in human skin fibroblasts. Furthermore, IGF-I-treated cells showed increased senescence-associated β-galactosidase activity and expression of p53 and p21 protein. IGF-I-treated cells reached the Hayflick limit earlier than GH- or vehicle-treated cells, indicating that IGF-I induces cellular senescence.Shortened telomeres in acromegaly and cellular senescence induced by IGF-I can explain, in part, the underlying mechanisms by which acromegaly exhibits an increased morbidity and mortality in association with the excess secretion of IGF-I.

  4. A vacuum-sealed, gigawatt-class, repetitively pulsed high-power microwave source

    Xun, Tao; Fan, Yu-wei; Yang, Han-wu; Zhang, Zi-cheng; Chen, Dong-qun; Zhang, Jian-de

    2017-06-01

    A compact L-band sealed-tube magnetically insulated transmission line oscillator (MILO) has been developed that does not require bulky external vacuum pump for repetitive operations. This device with a ceramic insulated vacuum interface, a carbon fiber array cathode, and non-evaporable getters has a base vacuum pressure in the low 10-6 Pa range. A dynamic 3-D Monte-Carlo model for the molecular flow movement and collision was setup for the MILO chamber. The pulse desorption, gas evolution, and pressure distribution were exactly simulated. In the 5 Hz repetition rate experiments, using a 600 kV diode voltage and 48 kA beam current, the average radiated microwave power for 25 shots is about 3.4 GW in 45 ns pulse duration. The maximum equilibrium pressure is below 4.0 × 10-2 Pa, and no pulse shortening limitations are observed during the repetitive test in the sealed-tube condition.

  5. Instability during bunch shortening of an electron-cooled beam

    M. Takanaka

    2003-10-01

    Full Text Available Bunch shortening causes an electron-cooled beam to be space charge dominated at low energies. Instability during the bunch shortening has been studied using a particle-tracking program where the 3D space-charge field due to the beam is calculated with a simplifying model.

  6. [Extension of (extremely) shortened dental arches by fixed or removable partial dentures

    Witter, D.J.; Hoefnagel, R.A.; Snoek, P.A.; Creugers, N.H.J.

    2009-01-01

    Whether a shortened dental arch needs to be extended depends on the degree of the shortening. Four categories of shortened dental arches can be distinguished: 1. slightly shortened dental arches; 2. moderately shortened dental arches; 3. extremely shortened dental arches; and 4. asymmetrical

  7. Low-intensity pulsed ultrasound stimulates cell proliferation, proteoglycan synthesis and expression of growth factor-related genes in human nucleus pulposus cell line

    Y Kobayashi

    2009-06-01

    Full Text Available Low-intensity pulsed ultrasound (LIPUS stimulation has been shown to effect differentiation and activation of human chondrocytes. A study involving stimulation of rabbit disc cells with LIPUS revealed upregulation of cell proliferation and proteoglycan (PG synthesis. However, the effect of LIPUS on human nucleus pulposus cells has not been investigated. In the present study, therefore, we investigated whether LIPUS stimulation of a human nucleus pulposus cell line (HNPSV-1 exerted a positive effect on cellular activity. HNPSV-1 cells were encapsulated in 1.2% sodium alginate solution at 1x105 cells/ml and cultured at 10 beads/well in 6-well plates. The cells were stimulated for 20 min each day using a LIPUS generator, and the effects of LIPUS were evaluated by measuring DNA and PG synthesis. Furthermore, mRNA expression was analyzed by cDNA microarray using total RNA extracted from the cultured cells. Our study revealed no significant difference in cell proliferation between the control and the ultrasound treated groups. However, PG production was significantly upregulated in HNPSV cells stimulated at intensities of 15, 30, 60, and 120 mW/cm2 compared with the control. The results of cDNA array showed that LIPUS significantly stimulated the gene expression of growth factors and their receptors (BMP2, FGF7, TGFbetaR1 EGFRF1, VEGF. These findings suggest that LIPUS stimulation upregulates PG production in human nucleus pulposus cells by the enhancement of several matrix-related genes including growth factor-related genes. Safe and non-invasive stimulation using LIPUS may be a useful treatment for delaying the progression of disc degeneration.

  8. A Shortened Stress Measure in Military Nursing Personnel

    2017-10-17

    REPORT TYPE 3. DATES COVERED (From- To) 10/17/2017 Abstract 4. TITLE AND SUBTITLE Sa. CONTRACT NUMBER A Shortened Stress Measure in Military...Psychology 14. ABSTRACT A Shortened Stress Measure with Military Nursing Personnel Abstract Stress is a psychological construct with important...consequences for human health. A substantial number of stress measures are available that vary in length and dimensionality. The purpose of this study was to

  9. Telomere Shortening in Neurological Disorders: An Abundance of Unanswered Questions

    Eitan, Erez; Hutchison, Emmette R.; Mattson, Mark P.

    2014-01-01

    Telomeres, ribonucleoprotein complexes that cap eukaryotic chromosomes, typically shorten in leukocytes with aging. Aging is a primary risk factor for neurodegenerative disease (ND), and a common assumption has arisen that leukocyte telomere length (LTL) can serve as a predictor of neurological disease. However, the evidence for shorter LTL in Alzheimer’s and Parkinson’s patients is inconsistent. The diverse causes of telomere shortening may explain variability in LTL between studies and indi...

  10. Consequences of crown shortening canine teeth in Greenland sled dogs

    Kortegaard, H E; Anthony Knudsen, T; Dahl, S

    2015-01-01

    OBJECTIVES: To evaluate the consequences of crown shortening, focusing on the prevalence of pulp exposure and periapical pathology in Greenland sled dogs that had had their canine crowns shortened at an early age. METHODS: Five cadaver heads and 54 sled dogs underwent an oral examination for dental...... fractures and pulp exposure of canines. All canines were radiographed and evaluated for periapical pathology. RESULTS: The prevalence of canine pulp exposure in 12 (5 heads and 7 dogs) crown shortened dogs was 91 · 7%, and 21 · 3% in 47 not-crown shortened dogs. A significant (P pulp...... exposure of the canines in the crown shortened group compared to the not-crown shortened group was seen with a relative risk of 4 · 3 on a dog basis and a relative risk of 12 · 2 on a tooth basis. In dogs with pulp exposure of canines (n = 51) the prevalence of periapical pathology was 82 · 4%, but only 0...

  11. A study on occlusal stability in shortened dental arches.

    Sarita, Paulo T N; Kreulen, Cees M; Witter, Dick J; van't Hof, Martin; Creugers, Nico H J

    2003-01-01

    The aim of this study was to verify the hypothesis that shortened dental arches constitute a risk to occlusal stability. Using cluster samples, 725 subjects with shortened dental arches comprising intact anterior regions and zero to eight occluding pairs of posterior teeth and 125 subjects with complete dental arches were selected. Subjects with shortened dental arches were classified into eight categories according to arch length and symmetry. Parameters for occlusal stability were interdental spacing, occlusal tooth wear, occlusal contact of incisors in intercuspal position, and vertical and horizontal overlap. Additionally, tooth mobility and overeruption of unopposed teeth were assessed. Influence of independent variables (dental arch category, age, gender, and residence) on the parameters for occlusal stability was assessed by one-way ANOVA and Tukey's multiple range tests. Extreme shortened dental arches (zero to two pairs of occluding premolars) had significantly more interdental spacing, occlusal contact of incisors, and vertical overlap compared to complete dental arches. Occlusal wear and prevalence of mobile teeth were highest in these categories. The category with three to four occluding premolars had significantly more interdental spacing and, for the older age group, more anterior teeth in occlusal contact compared to complete dental arches. Age was consistently associated with increased changes in occlusal integrity. Signs of increased risk to occlusal stability seemed to occur in extreme shortened dental arches, whereas no such evidence was found for intermediate categories of shortened dental arches.

  12. Sequentially pulsed traveling wave accelerator

    Caporaso, George J [Livermore, CA; Nelson, Scott D [Patterson, CA; Poole, Brian R [Tracy, CA

    2009-08-18

    A sequentially pulsed traveling wave compact accelerator having two or more pulse forming lines each with a switch for producing a short acceleration pulse along a short length of a beam tube, and a trigger mechanism for sequentially triggering the switches so that a traveling axial electric field is produced along the beam tube in synchronism with an axially traversing pulsed beam of charged particles to serially impart energy to the particle beam.

  13. Matrix effects on the crystallization behaviour of butter and roll-in shortening in laminated bakery products.

    Mattice, Kristin D; Marangoni, Alejandro G

    2017-06-01

    Two hydrogenated roll-in shortenings (A & B), one non-hydrogenated roll-in shortening and butter were used to prepare croissants. The impact of the laminated dough matrix on fat crystallization was then investigated using powder X-ray diffraction (XRD), pulsed nuclear magnetic resonance (p-NMR) and differential scanning calorimetry (DSC). The fat contained within a croissant matrix has never before been analyzed using these techniques. In each case, XRD revealed that the polymorphism of a roll-in fat will be different when baked within the dough matrix than when simply heated and cooled on its own. Both hydrogenated roll-in shortenings and butter experienced only minor changes, largely retaining their β' polymorphs, but the non-hydrogenated shortening experienced significant conversion from β' to the β form. However, this conversion did not take place immediately upon cooling, but after approximately 24h of storage time. The fat contained within the croissants exhibited a significantly lower SFC than the same fats in bulk. Further, DSC results demonstrated that a greater temperature was required to completely melt all of the fat in a croissant than the same fat in bulk, observed visually as broader peaks in the melting endotherms. Analysis of croissant firmness over storage time, measured as the maximum force required to cut a croissant was used as an indication of potential sensory consequences. Results suggested that only croissants prepared with non-hydrogenated shortening experienced significant changes in firmness over one week of storage. These results indicate that there is an interaction between the shortenings and the ingredients of the croissant matrix, and given the differences observed between roll-in fats used, the extent of interaction is potentially influenced by the composition of the roll-in fat itself. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Pulsed electron beam generation with fast repetitive double pulse system

    Sharma, Surender Kumar; Deb, Pankaj; Shyam, Anurag, E-mail: surender80@gmail.com [Energetics and Electromagnetics Division, Bhabha Atomic Research Centre, Visakhapatnam (India); Sharma, Archana [Accelerator and Pulse Power Division, Bhabha Atomic Research Centre, Mumbai (India)

    2014-07-01

    Longer duration high voltage pulse (∼ 100 kV, 260 ns) is generated and reported using helical pulse forming line in compact geometry. The transmission line characteristics of the helical pulse forming line are also used to develop fast repetition double pulse system with very short inter pulse interval. It overcomes the limitations caused due to circuit parameters, power supplies and load characteristics for fast repetitive high voltage pulse generation. The high voltage double pulse of 100 kV, 100 ns with an inter pulse repetition interval of 30 ns is applied across the vacuum field emission diode for pulsed electron beam generation. The electron beam is generated from cathode material by application of negative high voltage (> 100 kV) across the diode by explosive electron emission process. The vacuum field emission diode is made of 40 mm diameter graphite cathode and SS mesh anode. The anode cathode gap was 6 mm and the drift tube diameter was 10 cm. The initial experimental results of pulsed electron beam generation with fast repetitive double pulse system are reported and discussed. (author)

  15. Cost and cost-effectiveness of tuberculosis treatment shortening: a model-based analysis.

    Gomez, G B; Dowdy, D W; Bastos, M L; Zwerling, A; Sweeney, S; Foster, N; Trajman, A; Islam, M A; Kapiga, S; Sinanovic, E; Knight, G M; White, R G; Wells, W A; Cobelens, F G; Vassall, A

    2016-12-01

    Despite improvements in treatment success rates for tuberculosis (TB), current six-month regimen duration remains a challenge for many National TB Programmes, health systems, and patients. There is increasing investment in the development of shortened regimens with a number of candidates in phase 3 trials. We developed an individual-based decision analytic model to assess the cost-effectiveness of a hypothetical four-month regimen for first-line treatment of TB, assuming non-inferiority to current regimens of six-month duration. The model was populated using extensive, empirically-collected data to estimate the economic impact on both health systems and patients of regimen shortening for first-line TB treatment in South Africa, Brazil, Bangladesh, and Tanzania. We explicitly considered 'real world' constraints such as sub-optimal guideline adherence. From a societal perspective, a shortened regimen, priced at USD1 per day, could be a cost-saving option in South Africa, Brazil, and Tanzania, but would not be cost-effective in Bangladesh when compared to one gross domestic product (GDP) per capita. Incorporating 'real world' constraints reduces cost-effectiveness. Patient-incurred costs could be reduced in all settings. From a health service perspective, increased drug costs need to be balanced against decreased delivery costs. The new regimen would remain a cost-effective option, when compared to each countries' GDP per capita, even if new drugs cost up to USD7.5 and USD53.8 per day in South Africa and Brazil; this threshold was above USD1 in Tanzania and under USD1 in Bangladesh. Reducing the duration of first-line TB treatment has the potential for substantial economic gains from a patient perspective. The potential economic gains for health services may also be important, but will be context-specific and dependent on the appropriate pricing of any new regimen.

  16. Shortened stapedius tendon: a rare cause of conductive hearing loss.

    Zawawi, F; Varshney, R; Schloss, M D

    2014-01-01

    Anomalies of the stapedius tendon have been reported to cause conductive hearing loss; in theory, such anomalies limit the movement of the stapes. To demonstrate a rare cause of conductive hearing loss resulting from anomaly of the stapedius tendon and to compare the clinical findings of this patient to other stapedius tendon anomalies reported in the literature. Case report of a single case of shortened stapedius tendon and a review of the English literature on stapedius tendon anomalies. This is a case report of a 15-year-old boy with shortened stapedius tendon causing unilateral hearing loss, accompanied by a review of the literature. Contrary to other reported cases, this patient did not have an ossified tendon, but rather an extremely short tendon. The boy regained normal hearing following excision of the stapedius tendon. A shortened stapedius tendon is a very rare diagnosis, yet it should be considered as a possible cause of conductive hearing loss.

  17. Augmentation of Deglutitive Thyrohyoid Muscle Shortening by the Shaker Exercise

    Mepani, Rachel; Antonik, Stephen; Massey, Benson; Kern, Mark; Logemann, Jerilyn; Pauloski, Barbara; Rademaker, Alfred; Easterling, Caryn

    2010-01-01

    Earlier studies of the effect of 6 weeks of the Shaker Exercise have shown significant increase in UES opening and anterior excursion of larynx and hyoid during swallowing in patients with upper esophageal sphincter (UES) dysfunction, resulting in elimination of aspiration and resumption of oral intake. This effect is attributed to strengthening of the suprahyoid muscles, as evidenced by comparison of electromyographic changes in muscle fatigue before and after completion of the exercise regime. The effect of this exercise on thyrohyoid muscle shortening is unknown. Therefore the aim of this study was to determine the effect of the exercise on thyrohyoid muscle shortening. We studied 11 dysphagic patients with UES dysfunction. Six were randomized to traditional swallowing therapy and five to the Shaker Exercise. Videofluoroscopy was used to measure deglutitive thyrohyoid shortening before and after completion of assigned therapy regimen. Maximum thyrohyoid muscle shortening occurred at close temporal proximity to the time of maximal thyroid cartilage excursion. The percent change in thyrohyoid distance from initiation of deglutition to maximal anterior/superior hyoid excursion showed no statistically significant difference between the two groups prior to either therapy (p = 0.54). In contrast, after completion of therapy, the percent change in thyrohyoid distance in the Shaker Exercise group was significantly greater compared to the traditional therapy (p = 0.034). The Shaker Exercise augments the thyrohyoid muscle shortening in addition to strengthening the suprahyoid muscles. The combination of increased thyrohyoid shortening and suprahyoid strengthening contributes to the Shaker Exercise outcome of deglutitive UES opening augmentation. PMID:18685891

  18. Pulsed rf excited spectrometer having improved pulse width control

    1977-01-01

    RF excitation for a spectrometer is obtained by pulse width modulating an RF carrier to produce the desired broadband RF exciting spectrum. The RF excitation includes a train of composite RF pulses, each composite pulse having a primary pulse portion of a first RF phase and a second pulse portion of a second RF phase opposite that of the first. In this manner, the finite rise and fall times of the primary pulse portion are compensated for by the corresponding rise and fall times of the secondary pulse portion. The primary pulse portion is lengthened by an amount equal to the secondary pulse portion so that the secondary pulse portion cancels the added primary pulse portion. In a spectrometer, the compensating second pulse component removes certain undesired side bands of the RF excitation caused by the finite rise and fall times of the applied RF pulses. The compensating second pulse component removes certain undesired side bands associated with each of the resonant lines of the excited resonance spectrum of the sample under analysis, particularly for wide band RF excitation

  19. Pulse Generator

    Greer, Lawrence (Inventor)

    2017-01-01

    An apparatus and a computer-implemented method for generating pulses synchronized to a rising edge of a tachometer signal from rotating machinery are disclosed. For example, in one embodiment, a pulse state machine may be configured to generate a plurality of pulses, and a period state machine may be configured to determine a period for each of the plurality of pulses.

  20. Parallel plate transmission line transformer

    Voeten, S.J.; Brussaard, G.J.H.; Pemen, A.J.M.

    2011-01-01

    A Transmission Line Transformer (TLT) can be used to transform high-voltage nanosecond pulses. These transformers rely on the fact that the length of the pulse is shorter than the transmission lines used. This allows connecting the transmission lines in parallel at the input and in series at the

  1. Device and method for shortening reactor process tubes

    Frantz, Charles E.; Alexander, William K.; Lander, Walter E. B.

    1980-01-01

    This disclosure describes a device and method for in situ shortening of nuclear reactor zirconium alloy process tubes which have grown as a result of radiation exposure. An upsetting technique is utilized which involves inductively heating a short band of a process tube with simultaneous application of an axial load sufficient to cause upsetting with an attendant decrease in length of the process tube.

  2. Telomere shortening reduces Alzheimer's disease amyloid pathology in mice

    Rolyan, Harshvardhan; Scheffold, Annika; Heinrich, Annette; Begus-Nahrmann, Yvonne; Langkopf, Britta Heike; Hoelter, Sabine M.; Vogt-Weisenhorn, Daniela M.; Liss, Birgit; Wurst, Wolfgang; Lie, Dieter Chichung; Thal, Dietmar Rudolf; Biber, Knut; Rudolph, Karl Lenhard

    Alzheimer's disease is a neurodegenerative disorder of the elderly and advancing age is the major risk factor for Alzheimer's disease development. Telomere shortening represents one of the molecular causes of ageing that limits the proliferative capacity of cells, including neural stem cells.

  3. Challenges in Shortening New Product Introduction in the Pharmaceutical Industry

    Hansen, Klaus Reinholdt Nyhuus; Grunow, Martin

    2010-01-01

    Drug developing companies are forced to utilize the effective protection of the patent by focusing on shortening the new product introduction [NPI] process measured as Time-to-Market [TTM]. Here the NPI process is considered and the trade-offs, which have to be address in the future are identifie...

  4. Masticatory efficiency of shortened dental arch subjects with ...

    Objective: The objective of this study was to compare the masticatory efficiency in subjects with shortened dental arch (SDA) before and after restoration with removable partial denture (RPD). Materials and Methods: This was a prospective study carried out on 36 consecutive patients. The subjects were asked to chew 5 g of ...

  5. Effects of post mortem temperature on rigor tension, shortening and ...

    Fully developed rigor mortis in muscle is characterised by maximum loss of extensibility. The course of post mortem changes in ostrich muscle was studied by following isometric tension, shortening and change in pH during the first 24 h post mortem within muscle strips from the muscularis gastrocnemius, pars interna at ...

  6. Knowledge and attitudes of dentists toward shortened dental arch ...

    Objective: The aim of this study was to assess and compare the knowledge and attitudes of dentists toward shortened dental arch (SDA) therapy in Saudi Arabia. Materials and Methods: In this cross‑sectional study, self‑designed‑structured questionnaires were distributed among specialists (SP), residents (RES), and ...

  7. Masticatory Efficiency of Shortened Dental Arch Subjects with ...

    2017-05-16

    May 16, 2017 ... of shortened dental arch subjects with removable partial denture: A comparative ... at the post- and pre-treatment phases was statistically significant (P = 0.001). The .... after the delivery of metal-based RPD with the denture in.

  8. Shortened duration of untreated first episode of psychosis

    Larsen, Tor Ketil; McGlashan, T H; Johannessen, Jan Olav

    2001-01-01

    OBJECTIVE: This study examined whether duration of untreated psychosis can be shortened in patients with first episodes of DSM-IV schizophrenia spectrum disorders and whether shorted duration alters patient appearance at treatment. METHOD: Two study groups were ascertained in the same Norwegian h...

  9. Telomere shortening and survival in free-living corvids

    Salomons, H.M.; Mulder, G.A.; Zande, L. van de; Haussmann, M.F.; Linskens, M.H.K.; Verhulst, S.

    2009-01-01

    Evidence accumulates that telomere shortening reflects lifestyle and predicts remaining lifespan, but little is known of telomere dynamics and their relation to survival under natural conditions. We present longitudinal telomere data in free-living jackdaws (Corvus monedula) and test hypotheses on

  10. Updating the induction module from single-pulse to double-pulses

    Huang Ziping; Wang Huacen; Deng Jianjun

    2002-01-01

    A double-pulse Linear Induced Accelerator (LIA) module is reconstructed based on a usual simple-pulse LIA module. By changing the length of one of the cables between the inductive cell and the Blumlein pulse forming line, two induction pulses with 90 ns FWHM and 150 kV pulse voltage are generated by the ferrite cores inductive cell. The interval time of the pulses is adjustable by changing the lengths of the cable

  11. Shortening a loop can increase protein native state entropy.

    Gavrilov, Yulian; Dagan, Shlomi; Levy, Yaakov

    2015-12-01

    Protein loops are essential structural elements that influence not only function but also protein stability and folding rates. It was recently reported that shortening a loop in the AcP protein may increase its native state conformational entropy. This effect on the entropy of the folded state can be much larger than the lower entropic penalty of ordering a shorter loop upon folding, and can therefore result in a more pronounced stabilization than predicted by polymer model for loop closure entropy. In this study, which aims at generalizing the effect of loop length shortening on native state dynamics, we use all-atom molecular dynamics simulations to study how gradual shortening a very long or solvent-exposed loop region in four different proteins can affect their stability. For two proteins, AcP and Ubc7, we show an increase in native state entropy in addition to the known effect of the loop length on the unfolded state entropy. However, for two permutants of SH3 domain, shortening a loop results only with the expected change in the entropy of the unfolded state, which nicely reproduces the observed experimental stabilization. Here, we show that an increase in the native state entropy following loop shortening is not unique to the AcP protein, yet nor is it a general rule that applies to all proteins following the truncation of any loop. This modification of the loop length on the folded state and on the unfolded state may result with a greater effect on protein stability. © 2015 Wiley Periodicals, Inc.

  12. Gelatinized wheat starch influences crystallization behaviour and structure of roll-in shortenings in laminated bakery products.

    Mattice, Kristin D; Marangoni, Alejandro G

    2018-03-15

    One hydrogenated and one non-hydrogenated shortening were baked with isolated components of a croissant matrix, including crystalline wheat starch, gelatinized wheat starch, gluten, and formed gluten network. The impact of the matrix components on fat crystallization was analyzed for polymorphism using powder X-ray diffraction, solid fat content by pulsed nuclear magnetic resonance and thermal behaviour by differential scanning calorimetry. When compared to results obtained from croissants prepared with the respective shortenings, samples containing gelatinized wheat starch displayed notably similar results: polymorphic conversion, from the β' to β form over storage, and visually broader peaks in the melting endotherms indicating a greater temperature was required to completely melt all of the fat. All other component mixtures behaved similar to the respective fats in bulk. The measured rate of crystallization was greater in samples containing gelatinized wheat starch, indicating that the gelatinized starch could act as a nucleation site to speed crystallization. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Spectroscopic characteristics of H-alpha/O-I atomic lines generated by nanosecond pulsed corona-like discharge in deionized water

    Pongrác, Branislav; Šimek, Milan; Člupek, Martin; Babický, Václav; Lukeš, Petr

    2018-01-01

    Roč. 51, č. 12 (2018), č. článku 124001. ISSN 0022-3727 R&D Projects: GA ČR(CZ) GA15-12987S Institutional support: RVO:61389021 Keywords : underwater discharge * nanosecond pulsed discharge * time-resolved emission spectroscopy Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: Fluids and plasma physics (including surface physics) Impact factor: 2.588, year: 2016 http://iopscience.iop.org/article/10.1088/1361-6463/aaabb1/meta

  14. Petawatt pulsed-power accelerator

    Stygar, William A.; Cuneo, Michael E.; Headley, Daniel I.; Ives, Harry C.; Ives, legal representative; Berry Cottrell; Leeper, Ramon J.; Mazarakis, Michael G.; Olson, Craig L.; Porter, John L.; Wagoner; Tim C.

    2010-03-16

    A petawatt pulsed-power accelerator can be driven by various types of electrical-pulse generators, including conventional Marx generators and linear-transformer drivers. The pulsed-power accelerator can be configured to drive an electrical load from one- or two-sides. Various types of loads can be driven; for example, the accelerator can be used to drive a high-current z-pinch load. When driven by slow-pulse generators (e.g., conventional Marx generators), the accelerator comprises an oil section comprising at least one pulse-generator level having a plurality of pulse generators; a water section comprising a pulse-forming circuit for each pulse generator and a level of monolithic triplate radial-transmission-line impedance transformers, that have variable impedance profiles, for each pulse-generator level; and a vacuum section comprising triplate magnetically insulated transmission lines that feed an electrical load. When driven by LTD generators or other fast-pulse generators, the need for the pulse-forming circuits in the water section can be eliminated.

  15. Foundations of pulsed power technology

    Lehr, Janet

    2018-01-01

    Pulsed power technologies could be an answer to many cutting-edge applications. The challenge is in how to develop this high-power/high-energy technology to fit current market demands of low-energy consuming applications. This book provides a comprehensive look at pulsed power technology and shows how it can be improved upon for the world of today and tomorrow. Foundations of Pulsed Power Technology focuses on the design and construction of the building blocks as well as their optimum assembly for synergetic high performance of the overall pulsed power system. Filled with numerous design examples throughout, the book offers chapter coverage on various subjects such as: Marx generators and Marx-like circuits; pulse transformers; pulse-forming lines; closing switches; opening switches; multi-gigawatt to multi-terawatt systems; energy storage in capacitor banks; electrical breakdown in gases; electrical breakdown in solids, liquids and vacuum; pulsed voltage and current measurements; electromagnetic interferen...

  16. 3’UTR Shortening Potentiates MicroRNA-Based Repression of Pro-differentiation Genes in Proliferating Human Cells

    Hoffman, Yonit; Bublik, Debora Rosa; P. Ugalde, Alejandro; Elkon, Ran; Biniashvili, Tammy; Agami, Reuven; Oren, Moshe; Pilpel, Yitzhak

    2016-01-01

    Most mammalian genes often feature alternative polyadenylation (APA) sites and hence diverse 3’UTR lengths. Proliferating cells were reported to favor APA sites that result in shorter 3’UTRs. One consequence of such shortening is escape of mRNAs from targeting by microRNAs (miRNAs) whose binding sites are eliminated. Such a mechanism might provide proliferation-related genes with an expression gain during normal or cancerous proliferation. Notably, miRNA sites tend to be more active when located near both ends of the 3’UTR compared to those located more centrally. Accordingly, miRNA sites located near the center of the full 3’UTR might become more active upon 3'UTR shortening. To address this conjecture we performed 3' sequencing to determine the 3' ends of all human UTRs in several cell lines. Remarkably, we found that conserved miRNA binding sites are preferentially enriched immediately upstream to APA sites, and this enrichment is more prominent in pro-differentiation/anti-proliferative genes. Binding sites of the miR17-92 cluster, upregulated in rapidly proliferating cells, are particularly enriched just upstream to APA sites, presumably conferring stronger inhibitory activity upon shortening. Thus 3’UTR shortening appears not only to enable escape from inhibition of growth promoting genes but also to potentiate repression of anti-proliferative genes. PMID:26908102

  17. 3'UTR Shortening Potentiates MicroRNA-Based Repression of Pro-differentiation Genes in Proliferating Human Cells.

    Yonit Hoffman

    2016-02-01

    Full Text Available Most mammalian genes often feature alternative polyadenylation (APA sites and hence diverse 3'UTR lengths. Proliferating cells were reported to favor APA sites that result in shorter 3'UTRs. One consequence of such shortening is escape of mRNAs from targeting by microRNAs (miRNAs whose binding sites are eliminated. Such a mechanism might provide proliferation-related genes with an expression gain during normal or cancerous proliferation. Notably, miRNA sites tend to be more active when located near both ends of the 3'UTR compared to those located more centrally. Accordingly, miRNA sites located near the center of the full 3'UTR might become more active upon 3'UTR shortening. To address this conjecture we performed 3' sequencing to determine the 3' ends of all human UTRs in several cell lines. Remarkably, we found that conserved miRNA binding sites are preferentially enriched immediately upstream to APA sites, and this enrichment is more prominent in pro-differentiation/anti-proliferative genes. Binding sites of the miR17-92 cluster, upregulated in rapidly proliferating cells, are particularly enriched just upstream to APA sites, presumably conferring stronger inhibitory activity upon shortening. Thus 3'UTR shortening appears not only to enable escape from inhibition of growth promoting genes but also to potentiate repression of anti-proliferative genes.

  18. New MR pulse sequence

    Harms, S.E.; Flamig, D.P.; Griffey, R.H.

    1990-01-01

    This paper describes a method for fat suppression for three-dimensional MR imaging. The FATS (fat-suppressed acquisition with echo time shortened) sequence employs a pair of opposing adiabatic half-passage RF pulses tuned on fat resonance. The imaging parameters are as follows: TR, 20 msec; TE, 21.7-3.2 msec; 1,024 x 128 x 128 acquired matrix; imaging time, approximately 11 minutes. A series of 54 examinations were performed. Excellent fat suppression with water excitation is achieved in all cases. The orbital images demonstrate superior resolution of small orbital lesions. The high signal-to-noise ratio (SNR) in cranial studies demonstrates excellent petrous bone and internal auditory canal anatomy

  19. Extruded Tunnel Lining System : Phase 1. Conceptual Design and Feasibility Testing.

    1979-09-01

    The Extruded Tunnel Lining System (ETLS) has been conceived as a means of continuously placing the final concrete tunnel lining directly behind a tunnel boring machine. The system will shorten the time required to excavate and line a tunnel section, ...

  20. Laser ablation comparison by picosecond pulses train and nanosecond pulse

    Lednev, V. N.; Filippov, M. N.; Bunkin, A. F.; Pershin, S. M.

    2015-12-01

    A comparison of laser ablation by a train of picosecond pulses and nanosecond pulses revealed a difference in laser craters, ablation thresholds, plasma sizes and spectral line intensities. Laser ablation with a train of picosecond pulses resulted in improved crater quality while ablated mass decreased up to 30%. A reduction in laser plasma dimensions for picosecond train ablation was observed while the intensity of atomic/ionic lines in the plasma spectra was greater by a factor of 2-4 indicating an improved excitation and atomization in the plasma.

  1. PULSE SYNTHESIZING GENERATOR

    Kerns, Q.A.

    1963-08-01

    >An electronlc circuit for synthesizing electrical current pulses having very fast rise times includes several sinewave generators tuned to progressively higher harmonic frequencies with signal amplitudes and phases selectable according to the Fourier series of the waveform that is to be synthesized. Phase control is provided by periodically triggering the generators at precisely controlled times. The outputs of the generators are combined in a coaxial transmission line. Any frequency-dependent delays that occur in the transmission line can be readily compensated for so that the desired signal wave shape is obtained at the output of the line. (AEC)

  2. Pulse timing for cataclysmic variables

    Chester, T.J.

    1979-01-01

    It is shown that present pulse timing measurements of cataclysmic variables can be explained by models of accretion disks in these systems, and thus such measurements can constrain disk models. The model for DQ Her correctly predicts the amplitude variation of the continuum pulsation and can also perhaps explain the asymmetric amplitude of the pulsed lambda4686 emission line. Several other predictions can be made from the model. In particular, if pulse timing measurements that resolve emission lines both in wavelength and in binary phase can be made, the projected orbital radius of the white dwarf could be deduced

  3. The psychometric properties of a shortened corporate entrepreneurship assessment instrument

    Renier Steyn

    2017-08-01

    Aim: The aim of this research was to evaluate the psychometric properties of a measure of entrepreneurial climate. Entrepreneurial climate was measured using a shortened version of the Hornsby, Kuratko and Zahra (2002 instrument, called the Corporate Entrepreneurship Assessment Instrument (CEAI. Making information on the psychometric properties of the instrument available directly relates to its utility. Setting: The setting was medium to large South African companies. A random sample of employees was drawn from 53 selected companies across South Africa, with 60 respondents per company (N = 3 180. Methods: A cross-sectional survey design was used. Several instruments were administered, including the shortened version of the CEAI. Cronbach’s alpha was used to test for reliability and several methods were used to test for validity. Correlation analysis was used to test for concurrent validity, convergent validity and divergent validity. Principle component factor analysis was used to test for factorial validity and a t-test to test for known-group validity. Results: The results showed that the reliability for the total score of the shortened version of the CEAI was acceptable at 0.758. The results also showed some evidence of concurrent validity, as well as homogeneity among the items. With regard to factorial validity, all items loaded in accordance with the subscales of the instrument. The measure was able to distinguish, as expected, between government organisations and private business entities, suggesting known-group validity. Convergent validity and divergent validity were also assessed. Interesting to note was that entrepreneurship climate correlates more with general employee attitude (e.g. employee engagement; R= 0.420, p < 0.001 and organisational commitment, R = 0.331, p < 0.001 than with self-reported innovation (R = 0.277, p < 0.001 and R = 0.267, p < 0.001. Contribution: This paper not only provided information on the reliability

  4. Muscle damage induced by stretch-shortening cycle exercise.

    Kyröläinen, H; Takala, T E; Komi, P V

    1998-03-01

    Strenuous stretch-shortening cycle exercise was used as a model to study the leakage of proteins from skeletal muscle. The analysis included serum levels of creatine kinase (S-CK), myoglobin (S-Mb), and carbonic anhydrase (S-CA III). Blood samples from power- (N=11) and endurance-trained (N=10) athletes were collected before, 0, and 2 h after the exercise, which consisted of a total of 400 jumps. The levels of all determined myocellular proteins increased immediately after the exercise (P exercise, and the ratio of S-CA III and S-Mb decreased (P recruitment order of motor units, and/or differences in training background.

  5. The role of nonlinear viscoelasticity on the functionality of laminating shortenings

    Macias-Rodriguez, Braulio A.; Peyronel, Fernanda; Marangoni, Alejandro G.

    2017-11-01

    The rheology of fats is essential for the development of homogeneous and continuous layered structures of doughs. Here, we define laminating shortenings in terms of rheological behavior displayed during linear-to-nonlinear shear deformations, investigated by large amplitude oscillatory shear rheology. Likewise, we associate the rheological behavior of the shortenings with structural length scales elucidated by ultra-small angle x-ray scattering and cryo-electron microscopy. Shortenings exhibited solid-like viscoelastic and viscoelastoplastic behaviors in the linear and nonlinear regimes respectively. In the nonlinear region, laminating shortenings dissipated more viscous energy (larger normalized dynamic viscosities) than a cake bakery shortening. The fat solid-like network of laminating shortening displayed a three-hierarchy structure and layered crystal aggregates, in comparison to two-hierarchy structure and spherical-like crystal aggregates of a cake shortening. We argue that the observed rheology, correlated to the structural network, is crucial for optimal laminating performance of shortenings.

  6. Powerful nanosecond pulse train generator

    Isakov, I.F.; Logachev, E.I.; Opekunov, M.S.; Pechenkin, S.A.; Remnev, G.E.; Usov, Yu.P.

    1987-01-01

    A generator permitting to shape on the load pulsed with the repetition frequency of 10 3 -10 6 Hz and more is described. The amplitude of shaped voltage pulses is up to 150 kV at pulse duration equal to 50 ns. The generator comprises connected in-series with the load two shaping and two transmission lines realized on the base of the KVI-300 low-ohmic cable. The shaping lines are supplied from two independently connected pulse voltage generators for obtaining time interval between pulses > 10 -6 s; they may be also supplied from one generator for obtaining time interval -6 s. At the expense of reducing losses in the discharge circuit the amplitude of the second pulse grows with increase of time interval between pulses up to 300 ns, further on the curve flat-topping exists. The described generator is used in high-current accelerators, in which the primary negative pulse results in generation of explosive-emission plasma, and the second positive pulse provides ion beam shaping including ions of heavy metal used for production of a potential electrode. The generator multipulse mode is used for successive ion acceleration in the transport system

  7. Variable exhumation rates and variable displacement rates: Documenting recent slowing of Himalayan shortening in western Bhutan

    McQuarrie, Nadine; Tobgay, Tobgay; Long, Sean P.; Reiners, Peter W.; Cosca, Michael A.

    2014-01-01

    We link exhumational variability in space and time to the evolving geometry of the Himalayan fold–thrust belt in western Bhutan. By combining new and published geochronologic and thermochronologic data we document the burial age, peak temperatures and complete cooling history from 20 Ma to the present over an across-strike distance of ∼125 km. These integrated cooling curves highlight windows of fast exhumation that vary spatially and temporally. We propose that pulses of fast exhumation are a result of structures that facilitate the vertical motion of material, illustrated in sequentially-restored cross sections. Due to a range of permissible geometries at depth, we explore and evaluate the impact of geometry on kinematics and rates of deformation. The linked cooling history and cross sections provide estimates of both magnitude and timing of thrust sheet displacement and highlight temporal variability in potential shortening rates. Structural and chronologic data illustrate a general north to south progression of Himalayan deformation, with emplacement of the Main Central thrust (MCT), Paro thrust and Shumar thrust by 12 to no later than 9 Ma. Two different geometries and kinematic scenarios for the Lesser Himalayan duplex are proposed. A north to south propagating duplex system requires that the southern portion of that system, south of the MCT, deformed and cooled by 9 Ma, leaving only the southernmost thrust sheets, including the Main Boundary and Main Frontal thrusts, to deform between 9 and 0 Ma. This limited post 9 Ma shortening would necessitate a marked slowdown in convergence accommodated on the Main Himalayan thrust. A two-tiered duplex system, which allows for the Paro window duplex and the southern Baxa duplex to form simultaneously, permits duplex formation and accompanying exhumation until 6 Ma. Limited cooling from ∼200 °C to the surface post 6 Ma suggests either a decrease in shortening rates from 6 to 0 Ma or that duplex formation and

  8. Semi-automated detection of fractional shortening in zebrafish embryo heart videos

    Nasrat Sara

    2016-09-01

    Full Text Available Quantifying cardiac functions in model organisms like embryonic zebrafish is of high importance in small molecule screens for new therapeutic compounds. One relevant cardiac parameter is the fractional shortening (FS. A method for semi-automatic quantification of FS in video recordings of zebrafish embryo hearts is presented. The software provides automated visual information about the end-systolic and end-diastolic stages of the heart by displaying corresponding colored lines into a Motion-mode display. After manually marking the ventricle diameters in frames of end-systolic and end-diastolic stages, the FS is calculated. The software was evaluated by comparing the results of the determination of FS with results obtained from another established method. Correlations of 0.96 < r < 0.99 between the two methods were found indicating that the new software provides comparable results for the determination of the FS.

  9. A shortened protocol for assessing cognitive bias in rats.

    Brydges, Nichola M; Hall, Lynsey

    2017-07-15

    Reliable measurement of affective state in animals is a significant goal of animal welfare. Such measurements would also improve the validity of pre-clinical mental health research which relies on animal models. However, at present, affective states in animals are inaccessible to direct measurement. In humans, changes in cognitive processing can give reliable indications of emotional state. Therefore, similar techniques are increasingly being used to gain proxy measures of affective states in animals. In particular, the 'cognitive bias' assay has gained popularity in recent years. Major disadvantages of this technique include length of time taken for animals to acquire the task (typically several weeks), negative experiences associated with task training, and issues of motivation. Here we present a shortened cognitive bias protocol using only positive reinforcers which must actively be responded to. The protocol took an average of 4days to complete, and produced similar results to previous, longer methods (minimum 30days). Specifically, rats housed in standard laboratory conditions demonstrated negative cognitive biases when presented with ambiguous stimuli, and took longer to make a decision when faced with an ambiguous stimulus. Compared to previous methods, this protocol is significantly shorter (average 4days vs. minimum 30days), utilises only positive reinforcers to avoid inducing negative affective states, and requires active responses to all cues, avoiding potential confounds of motivational state. We have successfully developed a shortened cognitive bias protocol, suitable for use with laboratory rats. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  10. Methods for Shortening and Extending the Carbon Chain in Carbohydrates

    Monrad, Rune Nygaard

    2008-01-01

    in this thesis focuses on the development and application of transition metal mediated methods for shortening and extending the carbon chain in carbohydrates thereby providing access to lower and higher sugars.A new catalytic procedure for shortening unprotected sugars by one carbon atom has been developed....... The procedure has been employed as the key step in a short five-step synthesis of the unnatural sugar L-threose in 74% overall yield from D-glucose. A zinc-mediated one-pot fragmentation-allylation reaction has been used to elongate D-glucose and D-ribose by three carbon atoms thereby producing carbohydrate......-derived α,ω-dienes, which have been converted into the natural products calystegine A3 and gabosine A. The glycosidase inhibitor calystegine A3 was produced by two similar routes from commercially available methyl α-D-glucopyranoside in 13 and 14 steps with 8.3 and 5.3% overall yield, respectively...

  11. Pulsed power liner for PLT energy systems

    Armellino, C.A.; Bronner, G.; Murray, J.G.

    1975-01-01

    PLT is Princeton University's latest Tokamak machine in the controlled thermonuclear fusion research effort. The OH (ohmic heating) and SF (shaping field) systems for the machine place a very high energy pulsed current load on the AC line feeding them. This paper describes the two systems and the steps taken to insure minimum effect on line regulation during the pulsed operation

  12. The effect of high frequency steep pulsed electric fields on in vitro and in vivo antitumor efficiency of ovarian cancer cell line skov3 and potential use in electrochemotherapy

    Zheng Fei-Yun

    2009-04-01

    Full Text Available Abstract Background Patients received electrochemotherapy often associated with unpleasant sensations mainly result from low-frequency electric pulse induced muscle contractions. Increasing the repetition frequency of electric pulse can reduce unpleasant sensations. However, due to the specificity of SPEF, frequency related antitumor efficiency need to be further clarified. The aim of this study was to compare in vitro cytotoxic and in vivo antitumor effect on ovarian cancer cell line SKOV3 by SPEF with different repetition frequencies. Explore potential benefits of using high frequency SPEF in order to be exploitable in electrochemotherapy. Methods For in vitro experiment, SKOV3 cell suspensions were exposed to SPEF with gradient increased frequencies (1, 60, 1 000, 5 000 Hz and electric field intensity (50, 100, 150, 200, 250, 300, 350, 400 V/cm respectively. For in vivo test, SKOV3 subcutaneous implanted tumor in BALB/c nude mice (nu/nu were exposure to SPEF with gradient increased frequencies (1, 60, 1 000, 5 000 Hz and fixed electric field intensity (250 V/cm (7 mice for each frequency and 7 for control. Antitumor efficiency was performed by in vitro cytotoxic assay and in vivo tumor growth inhibition rate, supplemented by histological and TEM observations. Data were analyzed using one-way ANOVA followed by the comparisons of multiple groups. Results SPEF with a given frequency and appropriate electric field intensity could achieve similar cytotoxicity until reached a plateau of maximum cytotoxicity (approx. 100%. SPEF with different frequencies had significant antitumor efficiency in comparison to the control group (P 0.05. Histological and TEM observations demonstrated obvious cell damages in response to SPEF exposure. Furthermore, SPEF with 5 kHz could induce apoptosis under TEM observations both in vitro and in vivo. Conclusion SPEF with high frequency could also achieve similar antitumor efficiency which can be used to reduce

  13. The application of shortened upper leaf mutant in barley breeding

    Jin Hua

    2004-01-01

    The shortened upper leaf mutant was induced from Fuji Nigo by γ-ray irradiation. Fuji Nigo, the mutant, cross-cut F 1 , F 2 and back-cross F 1 , F 2 were used to analyze mutant heredity by comparative study. The yield, chlorophyll content, light intensity, dry matter of mutant were investigated. The results showed that (1) the mutant character was controlled by a couple of nuclear genes which were partial dominance; (2) the transmittance of the mutant colony was better than that of Fuji Nigo and bottom dry matter was much more than that of Fuji Nigo; (3) under the condition of high fertilizer and high plant population , the yield of mutant was higher than that of Fuji Nigo; (4) the content of chlorophyll a in the mutant was higher than that in Fuji Nigo

  14. Trans Fatty Acid content in Danish margarines and shortenings

    Leth, Torben; Bysted, Anette; Hansen, Kirsten

    2003-01-01

    with similar investigations in 1992 and 1995. A gradual decline of TFA in Danish margarines was observed. From 1992 to 1995, a reduction of TFA from 10.4 to 3.6% took place in margarines with 20-40% linoleic acid. In 1999, TFA was practically absent in all the margarines, but it remained unchanged...... in shortenings, averaging about 6-7%. Long-chain TFA from hydrogenated,fish oil, although present in 13 brands in 1995, were not found at all in the 1999 samples. Trans-linoleic acids or CLA were not found. The reduction in TFA content in margarines has not resulted in a systematic change over the years...

  15. Psychometric evaluation of the shortened resilience scale among Alzheimer's caregivers.

    Wilks, Scott E

    2008-01-01

    The purpose of this study was to evaluate psychometric properties of the shortened Resilience Scale (15-item version RS15) among a sample of Alzheimer's caregivers. Self-reported data were collected from 229 participants at 2 Alzheimer's caregiver conferences. RS15 principal axis factoring indicated a single-dimensional solution with all items loaded. Reliability was strong. Convergent validity for the RS15 was suggested through its correlations with stress, family support, and friend support. Odds ratios showed significant likelihoods of high resilience given low stress and high social support. The results confirmed the RS15 to be a psychometrically sound measure that can be used to appraise the efficacy of adaptability among Alzheimer's caregivers.

  16. Physico-chemical properties and performance of high oleic and palm-based shortenings.

    Ramli, Muhamad Roddy; Lin, Siew Wai; Yoo, Cheah Kien; Idris, Nor Aini; Sahri, Miskandar Mat

    2008-01-01

    Solid fat from fractionation of palm-based products was converted into cake shortening at different processing conditions. High oleic palm stearin with an oleic content of 48.2 % was obtained from fractionation of high oleic palm oil which was produced locally. Palm product was blended with different soft oils at pre-determined ratio and further fractionated to obtain the solid fractions. These fractions were then converted into cake shortenings named as high oleic, N1 and N2 blends. The physico-chemical properties of the experimental shortenings were compared with those of control shortenings in terms of fatty acid composition (FAC), iodine value (IV), slip melting point (SMP), solid fat content (SFC) and polymorphic forms. Unlike the imported commercial shortenings as reported by other studies and the control, experimental shortenings were trans-free. The SMP and SFC of experimental samples, except for the N2 sample, fell within the ranges of commercial and control shortenings. The IV was higher than those of domestic shortenings but lower when compared to imported and control shortenings. They were also observed to be beta tending even though a mixture of beta and beta' was observed in the samples after 3 months of storage. The shortenings were also used in the making of pound cake and sensory evaluation showed the good performance of high oleic sample as compared to the other shortenings.

  17. Cortical T2 signal shortening in amyotrophic lateral sclerosis is not due to iron deposits

    Hecht, M.J.; Neundoerfer, B. [University of Erlangen-Nurenberg, Department of Neurology, Erlangen (Germany); Fellner, C.; Fellner, F.A. [University of Erlangen-Nurenberg, Institute of Diagnostic Radiology, Erlangen (Germany); Landes-Nervenklinik Wagner-Jauregg, Institute of Radiology, Linz (Austria); Schmid, A. [University of Erlangen-Nurenberg, Institute of Diagnostic Radiology, Erlangen (Germany)

    2005-11-01

    Signal shortening of the motor cortex in T2-weighted MR images is a frequent finding in patients with amyotrophic lateral sclerosis (ALS). The cause of signal shortening in ALS is unknown, although iron deposits have been suggested. To test this hypothesis, we acquired T2*-weighted gradient-echo (GRE) MR images in addition to T2-weighted turbo spin-echo in 69 patients with ALS. Signal shortening in T2-weighted images was found in 31 patients. In T2*-weighted GRE images, only three patients had signal shortening. One patient with additional bifrontal haemorrhage had frontal but no motor cortex signal shortening. Iron deposits do not cause cortical signal shortening in patients with ALS predominantly. Other factors are presumably more important in the generation of cortical T2 shortening in ALS. (orig.)

  18. Cortical T2 signal shortening in amyotrophic lateral sclerosis is not due to iron deposits

    Hecht, M.J.; Neundoerfer, B.; Fellner, C.; Fellner, F.A.; Schmid, A.

    2005-01-01

    Signal shortening of the motor cortex in T2-weighted MR images is a frequent finding in patients with amyotrophic lateral sclerosis (ALS). The cause of signal shortening in ALS is unknown, although iron deposits have been suggested. To test this hypothesis, we acquired T2*-weighted gradient-echo (GRE) MR images in addition to T2-weighted turbo spin-echo in 69 patients with ALS. Signal shortening in T2-weighted images was found in 31 patients. In T2*-weighted GRE images, only three patients had signal shortening. One patient with additional bifrontal haemorrhage had frontal but no motor cortex signal shortening. Iron deposits do not cause cortical signal shortening in patients with ALS predominantly. Other factors are presumably more important in the generation of cortical T2 shortening in ALS. (orig.)

  19. Generation of ozone by Ns-width pulsed power

    Shimomura, Naoyuki; Wakimoto, Masaya; Shinke, Yosuke; Nagata, Masayoshi; Namihira, Takao; Akiyama, Hidenori

    2002-01-01

    The demand of ozone will be increasing for wholesome and environment-conscious sterilizations. The generation of ozone using the pulsed power discharge will apply electron accelerations around the head of streamer discharge principally. The breakdown in reactor often limits the efficient generation. Therefore, the pulse shape should be controlled for dimension of the reactor. It is clear that a pulse shortening is one of effective approaches. Pulsed power voltage with ns-width applies for ozone generation. The effects, on concentration and efficiency of generation, of pulse shape, repetition rate of pulse, flow rate of oxygen gas, and dimension and configuration of reactor, are discussed. The dimension and configuration of the reactor are optimized for the pulse width

  20. Shortened cortical silent period in adductor spasmodic dysphonia: evidence for widespread cortical excitability.

    Samargia, Sharyl; Schmidt, Rebekah; Kimberley, Teresa Jacobson

    2014-02-07

    The purpose of this study was to compare cortical inhibition in the hand region of the primary motor cortex between subjects with focal hand dystonia (FHD), adductor spasmodic dysphonia (AdSD), and healthy controls. Data from 28 subjects were analyzed (FHD n=11, 53.25 ± 8.74 y; AdSD: n=8, 56.38 ± 7.5 y; and healthy controls: n=941.67 ± 10.85 y). All subjects received single pulse TMS to the left motor cortex to measure cortical silent period (CSP) in the right first dorsal interosseus (FDI) muscle. Duration of the CSP was measured and compared across groups. A one-way ANCOVA with age as a covariate revealed a significant group effect (p<0.001). Post hoc analysis revealed significantly longer CSP duration in the healthy group vs. AdSD group (p<0.001) and FHD group (p<0.001). These results suggest impaired intracortical inhibition is a neurophysiologic characteristic of FHD and AdSD. In addition, the shortened CSP in AdSD provides evidence to support a widespread decrease in cortical inhibition in areas of the motor cortex that represent an asymptomatic region of the body. These findings may inform future investigations of differential diagnosis as well as alternative treatments for focal dystonias. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  1. A 350 KV nanosecond pulse voltage generator with adjustable pulsed-width

    Wang, X.; Wang, M.; Chen, Y.Q.; Zeng, L.G.; Han, M.

    2002-01-01

    This paper presents a 350 kV nanosecond pulse voltage generator (NPVG). The voltage pulsed-width can be adjusted from 30 to 160 ns. The generator consists of: Marx generator, pulsed forming line (PFL), main switch and matched impedance. The output voltage of Marx generator is over than nU c (n- the stage number of Marx generator, U c -the charging voltage of capacitor). When the pulse forming line is terminated with an impedance that is over than the characteristic impedance of PFL, the higher voltage pulse was provided for the load

  2. Overexpression of the Large-Conductance, Ca2+-Activated K+ (BK) Channel Shortens Action Potential Duration in HL-1 Cardiomyocytes.

    Stimers, Joseph R; Song, Li; Rusch, Nancy J; Rhee, Sung W

    2015-01-01

    Long QT syndrome is characterized by a prolongation of the interval between the Q wave and the T wave on the electrocardiogram. This abnormality reflects a prolongation of the ventricular action potential caused by a number of genetic mutations or a variety of drugs. Since effective treatments are unavailable, we explored the possibility of using cardiac expression of the large-conductance, Ca2+-activated K+ (BK) channel to shorten action potential duration (APD). We hypothesized that expression of the pore-forming α subunit of human BK channels (hBKα) in HL-1 cells would shorten action potential duration in this mouse atrial cell line. Expression of hBKα had minimal effects on expression levels of other ion channels with the exception of a small but significant reduction in Kv11.1. Patch-clamped hBKα expressing HL-1 cells exhibited an outward voltage- and Ca2+-sensitive K+ current, which was inhibited by the BK channel blocker iberiotoxin (100 nM). This BK current phenotype was not detected in untransfected HL-1 cells or in HL-1 null cells sham-transfected with an empty vector. Importantly, APD in hBKα-expressing HL-1 cells averaged 14.3 ± 2.8 ms (n = 10), which represented a 53% reduction in APD compared to HL-1 null cells lacking BKα expression. APD in the latter cells averaged 31.0 ± 5.1 ms (n = 13). The shortened APD in hBKα-expressing cells was restored to normal duration by 100 nM iberiotoxin, suggesting that a repolarizing K+ current attributed to BK channels accounted for action potential shortening. These findings provide initial proof-of-concept that the introduction of hBKα channels into a cardiac cell line can shorten APD, and raise the possibility that gene-based interventions to increase hBKα channels in cardiac cells may hold promise as a therapeutic strategy for long QT syndrome.

  3. Binge-type behavior in rats consuming trans-fat-free shortening.

    Wojnicki, F H E; Charny, G; Corwin, R L W

    2008-07-05

    Studies from this and another laboratory involving an animal model of binge-type behavior have used vegetable shortening containing trans-fats. Due to reformulations by vegetable shortening manufacturers to remove trans-fats from their products, only trans-fat-free shortenings are now available. The goal of the present study was to assess binge-type behavior in rats with trans-fat and trans-free vegetable shortening. Trans-fat-free shortening was provided to three different groups of non-food-deprived male Sprague Dawley rats on different schedules of access: continuous access (24 h/day-7 days/week), daily access (1 h every day), and intermittent access (1 h on Mondays, Wednesdays, Fridays). Trans-fat shortening was provided to a fourth group on the intermittent access schedule. A fifth group had no shortening access (chow only). Both intermittent groups (trans-fat-free and trans-fat) consumed significantly more shortening during the 1-h period of availability than did the daily group, and there was no difference in shortening intakes between the intermittent groups. These results are identical to previous reports of binge-type behavior in rats using this model. Thus, binge-type behavior in the present behavioral model depends upon the schedule of access, not the presence of trans-fats in the shortening.

  4. Nanosecond bipolar pulse generators for bioelectrics.

    Xiao, Shu; Zhou, Chunrong; Yang, Enbo; Rajulapati, Sambasiva R

    2018-04-26

    Biological effects caused by a nanosecond pulse, such as cell membrane permeabilization, peripheral nerve excitation and cell blebbing, can be reduced or cancelled by applying another pulse of reversed polarity. Depending on the degree of cancellation, the pulse interval of these two pulses can be as long as dozens of microseconds. The cancellation effect diminishes as the pulse duration increases. To study the cancellation effect and potentially utilize it in electrotherapy, nanosecond bipolar pulse generators must be made available. An overview of the generators is given in this paper. A pulse forming line (PFL) that is matched at one end and shorted at the other end allows a bipolar pulse to be produced, but no delay can be inserted between the phases. Another generator employs a combination of a resistor, an inductor and a capacitor to form an RLC resonant circuit so that a bipolar pulse with a decaying magnitude can be generated. A third generator is a converter, which converts an existing unipolar pulse to a bipolar pulse. This is done by inserting an inductor in a transmission line. The first phase of the bipolar pulse is provided by the unipolar pulse's rising phase. The second phase is formed during the fall time of the unipolar pulse, when the inductor, which was previously charged during the flat part of the unipolar pulse, discharges its current to the load. The fourth type of generator uses multiple MOSFET switches stacked to turn on a pre-charged, bipolar RC network. This approach is the most flexible in that it can generate multiphasic pulses that have different amplitudes, delays, and durations. However, it may not be suitable for producing short nanosecond pulses (<100 ns), whereas the PFL approach and the RLC approach with gas switches are used for this range. Thus, each generator has its own advantages and applicable range. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Do right-ventricular trabeculae gain energetic advantage from having a greater velocity of shortening?

    Pham, Toan; Han, June-Chiew; Taberner, Andrew; Loiselle, Denis

    2017-10-15

    We designed a study to test whether velocity of shortening in right-ventricular tissue preparations is greater than that of the left side under conditions mimicking those encountered by the heart in vivo. Our experiments allowed us to explore whether greater velocity of shortening results in any energetic advantage. We found that velocity of shortening was higher in the rat right-ventricular trabeculae. These results at the tissue level seem paradoxical to the velocity of ventricular ejection at the organ level, and are not always in accord with shortening of unloaded cells. Despite greater velocity of shortening in right-ventricular trabeculae, they neither gained nor lost advantage with respect to both mechanical efficiency and the heat generated during shortening. Our study aimed to ascertain whether the interventricular difference of shortening velocity, reported for isolated cardiac tissues in vitro, affects interventricular mechano-energetic performance when tested under physiological conditions using a shortening protocol designed to mimic those in vivo. We isolated trabeculae from both ventricles of the rat, mounted them in a calorimeter, and performed experiments at 37°C and 5 Hz stimulus frequency to emulate conditions of the rat heart in vivo. Each trabecula was subjected to two experimental protocols: (i) isotonic work-loop contractions at a variety of afterloads, and (ii) isometric contractions at a variety of preloads. Velocity of shortening was calculated from the former protocol during the isotonic shortening phase of the contraction. Simultaneous measurements of force-length work and heat output allowed calculation of mechanical efficiency. The shortening-dependent thermal component was quantified from the difference in heat output between the two protocols. Our results show that both extent of shortening and velocity of shortening were higher in trabeculae from the right ventricle. Despite these differences, trabeculae from both ventricles

  6. Options for shortening nuclear power plant refueling outages

    Kastl, H.

    2001-01-01

    Deregulation of the European electricity market on 01.01.1999 forced a large number of electric utilities- especially nuclear power plant operators - to find ways of drastically cutting down their costs in order to be able to compete successfully within the new market environment. Nuclear power plants currently in operation mainly have three potential ways of reducing their power generating costs: by increasing plant availability, reducing fuel costs and cutting down operating costs. The optimization of plant refueling outages offers considerable potential for enhancing plant availability, but also helps bring down operating costs by reducing expenditure on maintenance. In order to optimize an outage in terms of its duration and costs, a variety of approaches are possible - all of which, however, involve certain key factors such as good organization, planning, logistics and control, improvement of equipment and tools, as well as motivation of personnel. Another aspect is the introduction of innovative technologies. In the last few years, such technologies have frequently enabled maintenance effort to be reduced, thus saving considerable time, and have also resulted in a need for fewer personnel to carry out the work, thus reducing radiation exposure. In many instances they have also improved the quality of work and outage performance as a whole. The paper uses recent examples to show how innovative technologies can contribute to-wards reducing nuclear plant maintenance costs and shorten the duration of refueling out-ages. (author)

  7. Shortening a Patient Experiences Survey for Medical Homes

    Judy H. Ng

    2015-12-01

    Full Text Available The Consumer Assessment of Healthcare Providers and Systems—Patient-Centered Medical Home (CAHPS PCMH Survey assesses patient experiences reflecting domains of care related to general patient experience (access to care, communication with providers, office staff interaction, provider rating and PCMH-specific aspects of patient care (comprehensiveness of care, self-management support, shared decision making. The current work compares psychometric properties of the current survey and a proposed shortened version of the survey (from 52 to 26 adult survey items, from 66 to 31 child survey items. The revisions were based on initial psychometric analysis and stakeholder input regarding survey length concerns. A total of 268 practices voluntarily submitted adult surveys and 58 submitted child survey data to the National Committee for Quality Assurance in 2013. Mean unadjusted scores, practice-level item and composite reliability, and item-to-scale correlations were calculated. Results show that the shorter adult survey has lower reliability, but still it still meets general definitions of a sound survey for the adult version, and resulted in few changes to mean scores. The impact was more problematic for the pediatric version. Further testing is needed to investigate approaches to improving survey response and the relevance of survey items in informing quality improvement.

  8. Is the shortened dental arch still a satisfactory option?

    Manola, M; Hussain, F; Millar, B J

    2017-07-21

    Aims Dental practitioners may hold the view that missing posterior teeth should be replaced to ensure a healthy masticatory system and satisfactory oral function. However, the shortened dental arch (SDA) concept is still in use, but after 35 years is it acceptable? This review searches the literature for the evidence and opinions regarding the suitability of the SDA as a current treatment modality.Methods Medline and PubMed databases were searched for relevant terms, all the abstracts were assessed and articles selected according to the pre-set exclusion and inclusion criteria.Results The search yielded 1,895 articles and after the assessment of the abstracts and application of the exclusion and inclusion criteria, 44 articles were selected for this review. These included 11 cohort studies, two longitudinal studies, two animal studies, three cross sectional studies, eight clinical studies and 18 case control studies. There appears to be a trend over the past three decades for more papers to be opposed to the SDA concept.Conclusion Evidence that the SDA causes pathology is lacking. Clinicians, healthcare authorities and patients have shown favourable attitudes towards the SDA and this continues, although there is an increase in studies opposing the concept and some are dissatisfied with this option. The concept remains viable particularly for the medically compromised patient or where restorations are considered unsuitable but further more specific studies are warranted.

  9. Placental telomere shortening in stillbirth: a sign of premature senescence?

    Ferrari, Francesca; Facchinetti, Fabio; Saade, George; Menon, Ramkumar

    2016-01-01

    The objective of this study is to investigate placental telomere shortening in unexplained stillbirths (SBs) as an indication of premature senescence. Placentas were collected from 42 unexplained SB (>22 weeks), 43 term and 15 preterm live births, at the Policlinico Hospital of Modena (Italy). DNA extracted from placentae was studied for telomere length by real time PCR. Standard curves were generated for telomere lengths from single copy gene amplifications using a reference DNA. The telomere length for each sample was derived based on the ratio of telomere length between the sample and single copy gene standard (T/S ratio). The mean ratio of placental telomere in term live births was 5.181 ± 3.841. A twofold decrease in telomere length was seen in SBs (over all 2.455 ± 1.239; p PTBs) (6.382 ± 5.525; p < 0.01), whereas SBs telomere length were similar to those of preterm premature rupture of membranes (pPROM) (3.296 ± 3.599; p = ns). Substantial reduction in telomere length in SBs is indicative of placental senescence. These data provide mechanistic insights that premature aging may lead to placental dysfunction as an initiator of fetal demise in unexplained SBs.

  10. Chemical Sharpening, Shortening, and Unzipping of Boron Nitride Nanotubes

    Liao, Yunlong; Chen, Zhongfang; Connell, John W.; Fay, Catharine C.; Park, Cheol; Kim, Jae-Woo; Lin, Yi

    2014-01-01

    Boron nitride nanotubes (BNNTs), the one-dimensional member of the boron nitride nanostructure family, are generally accepted to be highly inert to oxidative treatments and can only be covalently modifi ed by highly reactive species. Conversely, it is discovered that the BNNTs can be chemically dispersed and their morphology modifi ed by a relatively mild method: simply sonicating the nanotubes in aqueous ammonia solution. The dispersed nanotubes are significantly corroded, with end-caps removed, tips sharpened, and walls thinned. The sonication treatment in aqueous ammonia solution also removes amorphous BN impurities and shortened BNNTs, resembling various oxidative treatments of carbon nanotubes. Importantly, the majority of BNNTs are at least partially longitudinally cut, or "unzipped". Entangled and freestanding BN nanoribbons (BNNRs), resulting from the unzipping, are found to be approximately 5-20 nm in width and up to a few hundred nanometers in length. This is the fi rst chemical method to obtain BNNRs from BNNT unzipping. This method is not derived from known carbon nanotube unzipping strategies, but is unique to BNNTs because the use of aqueous ammonia solutions specifi cally targets the B-N bond network. This study may pave the way for convenient processing of BNNTs, previously thought to be highly inert, toward controlling their dispersion, purity, lengths, and electronic properties.

  11. Pulse plating

    Hansal, Wolfgang E G; Green, Todd; Leisner, Peter; Reichenbach, Andreas

    2012-01-01

    The electrodeposition of metals using pulsed current has achieved practical importance in recent years. Although it has long been known that changes in potential, with or without polarity reversal, can significantly affect the deposition process, the practical application of this has been slow to be adopted. This can largely be explained in terms of the complex relationship between the current regime and its effect on the electrodeposition process. In order to harness these effects, an understanding of the anodic and cathodic electrochemical processes is necessary, together with the effects of polarity reversal and the rate of such reversals. In this new monograph, the basics of metal electrodeposition from solution are laid out in great detail in seven distinct chapters. With this knowledge, the reader is able to predict how a given pulse train profile can be adopted to achieve a desired outcome. Equally important is the choice of a suitable rectifier and the ancillary control circuits to enable pulse platin...

  12. New fat suppression RF pulse with shorter duration

    Yamaguchi, Kojiro; Ukai, Hiroyuki

    2010-01-01

    The fat suppression radio frequency pulse currently employed for MRI, which selectively saturates the frequency of the fat, has the narrow-band frequency characteristics. Therefore, the application duration for the pulse employed tends to be prolonged. In the present study, we designed a new fat suppression radiofrequency (RF) pulse using the Laguerre function in order to shorten the duration for fat suppression RF pulse and conducted an evaluation with the clinical equipment. The length of the RF pulse that we created allowed to reduce the duration by 47.3% compared with that employed for the clinical equipment. In addition, in the MR imaging evaluation, the new pulse was confirmed to have the fat suppression effect equivalent to that employed for the clinical equipment. (author)

  13. Fast pulse amplifier

    Lepetit, J.; Poussier, E.

    1984-01-01

    This amplifier comprises an inverter transformer, the primary circuit of which receives a pulse and the secondary circuit of which is connected to several amplifying elements in parallel. The inverter transformer is made of coaxial cable segments winded around a magnetic torus; the cable cores connected in series constitute the primary circuit and the braiding of cables, connected in parallel, are the secondary circuit. The transformer comprises, besides, delay lines in series with each braiding of the secondary circuit, these ones are such that pulses issued from each braiding arrive together to the secondary circuit connectors. This invention applies, noticeably in the case of a high voltage amplifier, to the control of deflection blocks of particles used in medicine or in particle accelerators [fr

  14. Influence of pulse width and target density on pulsed laser deposition of thin YBaCuO film

    Vikram, S.

    1999-01-01

    We have studied the effects of temporal pulse width and target density on the deposition of thin films of YBaCuO. A 248nm excimer laser and an 825nm Ti-sapphire laser were used to conduct the experiments with pulse widths of 27 ns, 16 ns, and 150 fs, and target densities of 80% and 90%. Scanning electron microscope photomicrographs and profilometer traces show a striking difference between nanosecond and femtosecond laser irradiation. Shortening the pulse width reduced particulate formation, provided stoichiometry, and improved the film properties. Decreasing the target density raised the ablation rate, produced thicker but nonuniform films, and reduced particulate formation

  15. Influence of pulse width and target density on pulsed laser deposition of thin YBaCuO film.

    Vikram, S.

    1999-01-20

    We have studied the effects of temporal pulse width and target density on the deposition of thin films of YBaCuO. A 248nm excimer laser and an 825nm Ti-sapphire laser were used to conduct the experiments with pulse widths of 27 ns, 16 ns, and 150 fs, and target densities of 80% and 90%. Scanning electron microscope photomicrographs and profilometer traces show a striking difference between nanosecond and femtosecond laser irradiation. Shortening the pulse width reduced particulate formation, provided stoichiometry, and improved the film properties. Decreasing the target density raised the ablation rate, produced thicker but nonuniform films, and reduced particulate formation.

  16. Short-pulse optical parametric chirped-pulse amplification for the generation of high-power few-cycle pulses

    Major, Zs.; Osterhoff, J.; Hoerlein, R.; Karsch, S.; Fuoloep, J.A.; Krausz, F.; Ludwig-Maximilians Universitaet, Muenchen

    2006-01-01

    Complete test of publication follows. In the quest for a way to generate ultrashort, high-power, few-cycle laser pulses the discovery of optical parametric amplification (OPA) has opened up to the path towards a completely new regime, well beyond that of conventional laser amplification technology. The main advantage of this parametric amplification process is that it allows for an extremely broad amplification bandwidth compared to any known laser amplifier medium. When combined with the chirped-pulse amplification (CPA) principle (i.e. OPCPA), on one hand pulses of just 10 fs duration and 8 mJ pulse energy have been demonstrated. On the other hand, pulse energies of up to 30 J were also achieved on a different OPCPA system; the pulse duration in this case, however, was 100 fs. In order to combine ultrashort pulse durations (i.e. pulses in the few-cycle regime) with high pulse energies (i.e. in the Joule range) we propose tu pump on OPCPA chain with TW-scale short pulses (100 fs - 1 ps instead of > 100 ps of previous OPCPA systems) delivered by a conventional CPA system. This approach inherently improves the conditions for generating high-power ultrashort pulses using OPCPA in the following ways. Firstly, the short pump pulse duration reduces the necessary stretching factor for the seed pulse, thereby increasing stretching and compression fidelity. Secondly, also due to the shortened pump pulse duration, a much higher contrast is achieved. Finally, the significantly increased pump power makes the use of thinner OPCPA crystals possible, which implies an even broader amplification bandwidth, thereby allowing for even shorter pulses. We carried out theoretical investigations to show the feasibility of such a set-up. Alongside these studies we will also present preliminary experimental results of an OPCPA system pumped by the output of our Ti:Sapphire ATLAS laser, currently delivering 350 mJ in 43 fs. An insight into the planned scaling of this technique to petawatt

  17. Compatibility of selected plant-based shortening as lard substitute: microstructure, polymorphic forms and textural properties

    N. A.M. Yanty

    2017-03-01

    Full Text Available A study was carried out to determine the compatibility of three plant-based shortening mixtures to lard shortening (LD in terms of microstructure, polymorphic forms, and textural properties. The shortenings of binary, ternary, and quaternary fat mixtures were prepared according to a standard procedure by blending mee fat (MF with palm stearin (PS in a 99:1 (w/w ratio; avocado fat (Avo with PS and cocoa butter (CB in a 84:7:9 (w/w ratio; palm oil (PO with PS, soybean oil (SBO and CB in a 38:5:52:5 (w/w ratio, respectively. The triacylglycerol composition, polymorphic forms, crystal morphology, and textural properties of the shortening were evaluated. This study found that all three plant-based shortenings and LD shortening were similar with respect to their consistency, hardness and compression and adhesiveness values. However, all plant-based shortening was found to be dissimilar to LD shortening with respect to microstructure.

  18. Molecular-dynamics simulation of crystalline 18-crown-6: thermal shortening of covalent bonds

    van Eerden, J.; Harkema, Sybolt; Feil, D.

    1990-01-01

    Molecular-dynamics simulations of crystalline 18-crown-6 have been performed in a study of the apparent thermal shortening of covalent bonds observed in crystal structures. At 100 K, a shortening of 0.006 _+ 0.001 A for C----C and C----O bonds was obtained. This result was found to be independent of

  19. Compatibility of selected plant-based shortening as lard substitute: microstructure, polymorphic forms and textural properties

    Yanty, N.A.M.; Marikkar, J.M.N.; Miskandar, M.S.; Bockstaele, F. Van; Dewettinck, K.; Nusantoro, B.P.

    2017-01-01

    A study was carried out to determine the compatibility of three plant-based shortening mixtures to lard shortening (LD) in terms of microstructure, polymorphic forms, and textural properties. The shortenings of binary, ternary, and quaternary fat mixtures were prepared according to a standard procedure by blending mee fat (MF) with palm stearin (PS) in a 99:1 (w/w) ratio; avocado fat (Avo) with PS and cocoa butter (CB) in a 84:7:9 (w/w) ratio; palm oil (PO) with PS, soybean oil (SBO) and CB in a 38:5:52:5 (w/w) ratio, respectively. The triacylglycerol composition, polymorphic forms, crystal morphology, and textural properties of the shortening were evaluated. This study found that all three plant-based shortenings and LD shortening were similar with respect to their consistency, hardness and compression and adhesiveness values. However, all plant-based shortening was found to be dissimilar to LD shortening with respect to microstructure. [es

  20. The Shortened Raven Standard Progressive Matrices: Item Response Theory-Based Psychometric Analyses and Normative Data

    Van der Elst, Wim; Ouwehand, Carolijn; van Rijn, Peter; Lee, Nikki; Van Boxtel, Martin; Jolles, Jelle

    2013-01-01

    The purpose of the present study was to evaluate the psychometric properties of a shortened version of the Raven Standard Progressive Matrices (SPM) under an item response theory framework (the one- and two-parameter logistic models). The shortened Raven SPM was administered to N = 453 cognitively healthy adults aged between 24 and 83 years. The…

  1. Influence of muscle geometry on shortening speed of fibre, aponeurosis and muscle

    Zuurbier, C. J.; Huijing, P. A.

    1992-01-01

    The influence of muscle geometry on muscle shortening of the gastrocnemius medialis muscle (GM) of the rat was studied. Using cinematography, GM geometry was studied during isokinetic concentric activity at muscle lengths ranging from 85 to 105% of the optimum muscle length. The shortening speed of

  2. The shortened cochlea: its classification and histopathologic features.

    Zheng, Yiqing; Schachern, Patricia A; Cureoglu, Sebahattin; Mutlu, Cemil; Dijalilian, Hamid; Paparella, Michael M

    2002-03-15

    The term 'Mondini dysplasia' has been used to describe virtually any congenital abnormality of the osseous labyrinth resulting in confusion and seemingly contradictory observations and conclusions about this type of deformity. The purpose of this study is to histopathologically classify and describe temporal bones whose cochleas have less than 2.5 turns. Of the 1800 temporal bones in our collection, 21 from 12 cases were found to have cochleas with less than 2.5 cochlear turns. Ages ranged from stillborn to 50 years. Temporal bones were harvested at autopsy, processed and embedded in celloidin. Sections were cut at a thickness of 20 microm and every 10th section stained with hematoxylin-eosin and examined using light microscopy. The number of turns, length of cochlea, integrity of cochlear base, length of modiolus, abnormalities of the semicircular canals and vestibule, enlargement of the vestibular aqueduct and middle ears were documented. Twenty-one temporal bones from age-matched patients without cochlear deformities were used as controls for modiolar length measurements. Malformation of the shortened cochlea was histopathologically classified into three groups as follows: (1) Common cavity, cochlear dysplasia (one ear)--severe dysplasia of the cochlea without a complete basal turn; (2) Mondini dysplasia (11 ears)--1.5 cochlear turns, a complete basal turn, an incomplete or absent interscalar septum and a complete bone at the base of the modiolus; and (3) Mondini-like dysplasia type A (five ears)--2 turns to the cochlea including a complete basal turn and complete bone at the base of the modiolus; and type B (four ears)--1.5-2 turns to the cochlea, hypoplasia of or a missing bone at the base of the modiolus (either with or without a communication between the internal auditory canal and the cochlea) and a complete basal turn. The range of congenital malformations in short cochlea is highly variable. Fundamental to the accurate evaluation of a labyrinthine anomaly

  3. Comparison of vegetable shortening and cocoa butter as vehicles for cortisol manipulation in Salmo trutta

    Birnie-Gauvin, Kim; Peiman, K. S.; Larsen, M. H.

    2018-01-01

    This study demonstrates that vegetable shortening and cocoa butter are two effective vehicles for intraperitoneal cortisol implants in juvenile teleosts, specifically brown trout Salmo trutta, residing in north temperate freshwater environments. Each vehicle showed a different pattern of cortisol...... elevation. Vegetable shortening was found to be a more suitable vehicle for long-term cortisol elevation [elevated at 3, 6 and 9 days post treatment (dpt)], while cocoa butter may be better suited for short-term cortisol elevation (only elevated at 3 dpt). Additionally, plasma cortisol levels were higher...... with cortisol–vegetable shortening than with cortisol–cocoa butter implants. Plasma glucose levels were elevated 6 and 9 dpt for fishes injected with cortisol–vegetable shortening, but did not change relative to controls and shams in cortisol–cocoa butter fishes. In conclusion, vegetable shortening and cocoa...

  4. Evaluation of bipolar pulse generator for high-purity pulsed ion beam

    Ito, H.; Kitamura, I.; Masugata, K.

    2008-01-01

    A new type of pulsed ion beam accelerator named 'bipolar pulse accelerator (BPA)' has been proposed in order to improve the purity of intense pulsed ion beams. To confirm the principle of the BPA, we developed a bipolar pulse generator, which consists of a Marx generator and a pulse forming line (PFL) with a rail gap switch on its end. In this article, we report the experimental results of the bipolar pulse and evaluate the electrical characteristics of the bipolar pulse generator. When the bipolar pulse generator was operated at 70% of the full charge condition of the PEL, the bipolar pulse with the first (-138 kV, 72 ns) and the second pulse (+130 kV, 70 ns) was successfully obtained. The evaluation of the electrical characteristics indicates that the developed generator can produce the bipolar pulse with fast rise time and sharp reversing time. At present the bipolar pulse generator is installed in the B y type magnetically insulated ion diode and we carry out the experiment on the production of an intense pulsed ion beam by the bipolar pulse accelerator. (author)

  5. A system for long pulse REB generation

    Tsuzuki, Tetsuya; Hasegawa, Mitsuru; Narihara, Kazumichi; Tomita, Yukihiro; Kubo, Shin; Kobata, Tadasuke; Mohri, Akihiro.

    1987-02-01

    A high voltage pulse generator system producing intense relativistic electron beams (REB) (1.5 μs pulse width, 30 kA peak current, 1 MeV energy) was developed to the use of REB ring formation. The system consists of a Marx generator, a transmission line with plastics-water hybrid insulators and a magnetically insulated transmission line connected with a cathode. The system has been well operated more than twenty thousands shots without troubles. (author)

  6. Rapid bioassay-guided screening of toxic substances in vegetable oils that shorten the life of SHRSP rats

    Lewandowski Paul

    2010-02-01

    Full Text Available Abstract It has been consistently reported that vegetable oils including canola oil have a life shortening effect in Stroke-Prone Spontaneously Hypertensive Rats (SHRSP and this toxic effect is not due to the fatty acid composition of the oil. Although it is possible that the phytosterol content or type of phytosterol present in vegetable oils may play some role in the life shortening effect observed in SHRSP rats this is still not completely resolved. Furthermore supercritical CO2 fractionation of canola oil with subsequent testing in SHRSP rats identified safe and toxic fractions however, the compounds responsible for life shortening effect were not characterised. The conventional approach to screen toxic substances in oils using rats takes more than six months and involves large number of animals. In this article we describe how rapid bioassay-guided screening could be used to identify toxic substances derived from vegetable oils and/or processed foods fortified with vegetable oils. The technique incorporates sequential fractionation of oils/processed foods and subsequent treatment of human cell lines that can be used in place of animal studies to determine cytotoxicity of the fractions with structural elucidation of compounds of interest determined via HPLC-MS and GC-MS. The rapid bioassay-guided screening proposed would require two weeks to test multiple fractions from oils, compared with six months if animal experiments were used to screen toxic effects. Fractionation of oil before bio-assay enhances the effectiveness of the detection of active compounds as fractionation increases the relative concentration of minor components.

  7. Pulse sliced picosecond Ballistic Imaging and two planar elastic scattering: Development of the techniques and their application to diesel sprays

    Duran, Sean Patrick Hynes

    A line of sight imaging technique was developed which utilized pulse slicing of laser pulses to shorten the duration of the parent laser pulse, thereby making time gating more effective at removing multiple scattered light. This included the development of an optical train which utilized a Kerr cell to selectively pass the initial part of the laser pulse while rejecting photons contained later within the pulse. This line of sight ballistic imaging technique was applied to image high-pressure fuel sprays injected into conditions typically encountered in a diesel combustion chamber. Varying the environmental conditions into which the fuel was injected revealed trends in spray behavior which depend on both temperature and pressure. Different fuel types were also studied in this experiment which demonstrated remarkably different shedding structures from one another. Additional experiments were performed to characterize the imaging technique at ambient conditions. The technique was modified to use two wavelengths to allow further rejection of scattered light. The roles of spatial, temporal and polarization filtration were examined by imaging an USAF 1951 line-pair target through a highly scattering field of polystyrene micro-spheres. The optical density of the scattering field was varied by both the optical path length and number densities of the spheres. The equal optical density, but with variable path length results demonstrated the need for an aggressively shorter pulse length to effectively image the distance scales typical encountered in the primary breakup regions of diesel sprays. Results indicate that the system performance improved via the use of two wavelengths. A final investigation was undertaken to image coherent light which has elastically scattered orthogonal to the direction of the laser pulse. Two wavelengths were focused into ˜150 micron sheets via a cylindrical lens and passed under the injector nozzle. The two sheets were adjustable spatially to

  8. PULSE COLUMN

    Grimmett, E.S.

    1964-01-01

    This patent covers a continuous countercurrent liquidsolids contactor column having a number of contactor states each comprising a perforated plate, a layer of balls, and a downcomer tube; a liquid-pulsing piston; and a solids discharger formed of a conical section at the bottom of the column, and a tubular extension on the lowest downcomer terminating in the conical section. Between the conical section and the downcomer extension is formed a small annular opening, through which solids fall coming through the perforated plate of the lowest contactor stage. This annular opening is small enough that the pressure drop thereacross is greater than the pressure drop upward through the lowest contactor stage. (AEC)

  9. Pulse radiolysis

    Greenshields, H.; Seddon, W.A.

    1982-03-01

    This supplement to two bibliographies published in 1970 and 1972 lists 734 references to the literature of pulse radiolysis, arranged under eight broad subject headings. The references were compiled by searching Biological Abstracts, Chemical Abstracts, Nuclear Science Abstracts and the Weekly List of Papers in Radiation Chemistry issued by the Radiation Chemistry Data Center of Notre Dame University. Full bibliographic data is given for papers published in the period 1971 to 1974. A personal author index listing more than 600 authors and a similar number of co-authors is included

  10. Pulse pile-up. I: Short pulses

    Wilkinson, D.H.

    1990-07-01

    The search for rare large pulses against an intense background of smaller ones involves consideration of pulse pile-up. Approximate methods are presented, based on ruin theory, by which the probability of such pile-up may be estimated for pulses of arbitrary form and of arbitrary pulse-height distribution. These methods are checked against cases for which exact solutions are available. The present paper is concerned chiefly with short pulses of finite total duration. (Author) (5 refs., 24 figs.)

  11. PULSE Pilot Certification Results

    Pamela Pape-Lindstrom

    2015-08-01

    Full Text Available The pilot certification process is an ambitious, nationwide endeavor designed to motivate important changes in life sciences education that are in line with the recommendations of the 2011 Vision and Change Report: A Call to Action (American Association for the Advancement of Science [AAAS], 2011.  It is the goal of the certification process to acknowledge departments that have progressed towards full implementation of the tenets of Vision and Change and to motivate departments that have not begun to adopt the recommendations to consider doing so.  More than 70 life science departments applied to be part of the pilot certification process, funded by a National Science Foundation grant, and eight were selected based on initial evidence of transformed and innovative educational practices.  The programs chosen represent a wide variety of schools, including two-year colleges, liberal-arts institutions, regional comprehensive colleges, research universities and minority serving institutions.  Outcomes from this pilot were released June 1, 2015 (www.pulsecommunity.org, with all eight programs being recognized as having progressed along a continuum of change.  Five levels of achievement were defined as PULSE Pilot Progression Levels.  Of the eight departments in the pilot, one achieved “PULSE Progression Level III: Accomplished”.  Six departments achieved “PULSE Progression Level II: Developing” and one pilot department achieved “PULSE Progression Level I: Beginning”.  All of the schools have made significant movement towards the recommendations of Vision and Change relative to a traditional life sciences curriculum.  Overall, the response from the eight pilot schools has been positive. 

  12. A high-voltage pulse generator for corona plasma generation

    Yan, K.; Heesch, van E.J.M.; Pemen, A.J.M.; Huijbrechts, P.A.H.J.; Gompel, van F.M.; Leuken, van H.E.M.; Matyas, Z.

    2002-01-01

    This paper discusses a high-voltage pulse generator for producing corona plasma. The generator consists of three resonant charging circuits, a transmission line transformer, and a triggered spark-gap switch. Voltage pulses in the order of 30-100 kV with a rise time of 10-20 ns, a pulse duration of

  13. Pulsed chemical oxygen - iodine laser initiated by a transverse electric discharge

    Vagin, Nikolai P; Yuryshev, Nikolai N

    2001-01-01

    A pulsed chemical oxygen - iodine laser with a volume production of atomic iodine in a pulsed transverse electric discharge is studied. An increase in the partial oxygen pressure was shown to increase the pulse energy with retention of the pulse duration. At the same time, an increase in the iodide pressure and the discharge energy shortens the pulse duration. Pulses with a duration of 6.5 μs were obtained, which corresponds to a concentration of iodine atoms of 1.8 x 10 15 cm -3 . This concentration is close to the maximum concentration attained in studies of both cw and pulsed oxygen-iodine lasers. A specific energy output of 0.9 J litre -1 and a specific power of 75 kW litre -1 were obtained. The ways of increasing these parameters were indicated. It was found that SF 6 is an efficient buffer gas favouring improvements in the energy pulse parameters. (lasers)

  14. Induction linacs and pulsed power

    Caporaso, G.J.

    1995-01-01

    Progress in electronic power conversion technology is making possible a new class of induction linacs that can operate at extremely high repetition rates. Advances in insulator technology, pulse forming line design and switching may also lead to a new type of high current accelerator with accelerating gradients at least an order of magnitude greater than those attainable today. The evolution of the induction accelerator pulsed power system will be discussed along with some details of these emerging technologies which are at the frontiers of accelerator technology

  15. Vastus lateralis surface and single motor unit EMG following submaximal shortening and lengthening contractions

    Altenburg, T.M.; de Ruiter, C.J.; Verdijk, P.W.L.; van Mechelen, W.; de Haan, A.

    2008-01-01

    A single shortening contraction reduces the force capacity of muscle fibers, whereas force capacity is enhanced following lengthening. However, how motor unit recruitment and discharge rate (muscle activation) are adapted to such changes in force capacity during submaximal contractions remains

  16. Graphene oxide-loaded shortening as an environmentally friendly heat transfer fluid with high thermal conductivity

    Vongsetskul Thammasit

    2017-01-01

    Full Text Available Graphene oxide-loaded shortening (GOS, an environmentally friendly heat transfer fluid with high thermal conductivity, was successfully prepared by mixing graphene oxide (GO with a shortening. Scanning electron microscopy revealed that GO particles, prepared by the modified Hummer’s method, dispersed well in the shortening. In addition, the latent heat of GOS decreased while their viscosity and thermal conductivity increased with increasing the amount of loaded GO. The thermal conductivity of the GOS with 4% GO was higher than that of pure shortening of ca. three times, from 0.1751 to 0.6022 W/mK, and increased with increasing temperature. The GOS started to be degraded at ca. 360°C. After being heated and cooled at 100°C for 100 cycles, its viscosity slightly decreased and no chemical degradation was observed. Therefore, the prepared GOS is potentially used as environmentally friendly heat transfer fluid at high temperature.

  17. Lengthening of the shortened first metatarsal after Wilson's osteotomy for hallux valgus.

    Singh, D; Dudkiewicz, I

    2009-12-01

    Metatarsalgia is a recognised complication following iatrogenic shortening of the first metatarsal in the management of hallux valgus. The traditional surgical treatment is by shortening osteotomies of the lesser metatarsals. We describe the results of lengthening of iatrogenic first brachymetatarsia in 16 females. A Scarf-type osteotomy was used in the first four cases and a step-cut of equal thicknesses along the axis of the first metatarsal was performed in the others. The mean follow-up was 21 months (19 to 26). Relief of metatarsalgia was obtained in the six patients in whom 10 mm of lengthening had been achieved, compared to only 50% relief in those where less than 8 mm of lengthening had been gained. One-stage step-cut lengthening osteotomy of the first metatarsal may be preferable to shortening osteotomies of the lesser metatarsals in the treatment of metatarsalgia following surgical shortening of the first metatarsal.

  18. Quantum gravity removes classical singularities and shortens the life of black holes

    Frolov, V.P.; Vilkovisky, G.A.

    1979-07-01

    The problem of the gravitational collapse is considered in the framework of the quantum gravity effective action. It is shown that quantum gravity removes classical singularity and possibly shortens the lifetime of the black hole. (author)

  19. CAMAC differential pulse discriminator-counter

    Tselikov, N.V.

    1987-01-01

    Differential pulse discriminator-counter for Moessbauer spectrometer is described. Input pulse setting into the channel is performed according to the following algorithm: the pulse is transmitted to the channel depending on the fact whether the preceding pulse has got to the discrimination window or not. The circuit does not contain delay lines, taking into account the delay of a signal from the upper level discriminator in relation to the lower level discriminator signal, which is connected with input pulse rise finite time, which in turn allows one to reduce the discriminator dead time up to the operation time of threshold circuits. The pulse counting rate is 150 MHz, input signal amplitude is ±3 V, dead time is 6 ns, delay time from input to output is 14 ns. The unit is made in CAMAC system

  20. Shortening and Thickening of Metropolitan Los Angeles Measured and Inferred Using Geodesy

    Argus, D.; Heflin, M.; Donnellan, A.; Webb, F.; Dong, D.; Hurst, K.; Jefferson, D.; Lyzenga, G.; Watkins, M.; Zumberge, J.

    1999-01-01

    Geodetic measurements using the Global Positioning System and other techniques show north-south shortening near Los Angeles to be fastest across the northern part of the metropolitan area, where an ESE-striking, 5- to 40-km-wide belt lying to the south of San Gabriel Mountains and to the north of downtown and West Los Angeles is shortening at 5 mm/yr.

  1. Lateral mobility of minibasins during shortening: Insights from the SE Precaspian Basin, Kazakhstan

    Duffy, Oliver B.; Fernandez, Naiara; Hudec, Michael R.; Jackson, Martin P. A.; Burg, George; Dooley, Tim P.; Jackson, Christopher A.-L.

    2017-04-01

    Minibasin provinces are widespread and can be found in all types of salt tectonic settings, many of which are prone to shortening. Previous studies of how minibasin provinces shorten assume that the salt between the minibasins is homogeneous and that the base of salt is flat or of low relief, such that minibasins are free to move laterally. Here we investigate how minibasin provinces respond to shortening when the lateral mobility of the minibasins is restricted by intra-salt sediment bodies, in order to gain a greater understanding of the controls on the structural styles and modes of tectono-stratigraphic evolution exhibited in minibasin provinces. We examine a borehole-constrained, 3D seismic reflection dataset from the SE Precaspian Basin (onshore western Kazakhstan). The study area is characterised by large, supra-salt minibasins and an array of smaller intra-salt sediment packages distributed between these larger minibasins. We first outline the evidence of episodic shortening between the Late Triassic and present, after the onset of supra-salt minibasin subsidence. Next, we document spatial variations in shortening style, showing how these relate to the concentration of intra-salt sediment packages. Finally, we develop synoptic models showing how intra-salt sediment packages influence both the lateral mobility of minibasins during shortening and the resultant structural style, and we compare and contrast our findings with existing models and other natural examples of shortened minibasin provinces. We conclude that minibasin provinces may have different degrees of lateral mobility depending on the presence, or absence, of intrasalt barriers, and that these variations provide a first-order control on basin-shortening style and tectono-stratigraphic evolution.

  2. Damage sensing ability of polymer nanocomposites filled with long, shortened and damaged carbon nanotubes

    Inam, Fawad; Okolo, Chichi; Vo, Thuc

    2016-01-01

    Carbon nanotubes (CNTs) were aggressively tip-ultrasonicated to produce shortened and damaged carbon nanotubes. High-resolution scanning electron microscopic analysis was performed to measure the dimensions of CNTs. Thermo-gravimetric analysis (TGA) was used to evaluate the damage in the sonicated CNTs. Shortened CNTs, in their pristine form (undamaged), were used for comparison with damaged CNTs. Nanocomposite bars, containing CNTs, were indented using Vickers hardness testing machine to pro...

  3. Digital parallel-to-series pulse-train converter

    Hussey, J.

    1971-01-01

    Circuit converts number represented as two level signal on n-bit lines to series of pulses on one of two lines, depending on sign of number. Converter accepts parallel binary input data and produces number of output pulses equal to number represented by input data.

  4. Effect of shortening replacement with oleogels on the rheological and tomographic characteristics of aerated baked goods.

    Lim, Jeongtaek; Jeong, Sungmin; Lee, JaeHwan; Park, Sungkwon; Lee, Jonggil; Lee, Suyong

    2017-08-01

    A great deal of effort has been made to reduce the use of shortening owing to the high level of saturated fats as well as the presence of trans fats. Grape seed oil high in unsaturated fats was structured with candelilla wax to form solid-like oleogels that were utilized as a shortening replacer in aerated baked goods, specifically muffins. Muffin batters with greater amounts of oleogels exhibited lower viscosity, greater shear-thinning behavior and less elastic nature. The shortening replacement with oleogels significantly increased the specific gravity of the batters, consequently affecting the muffin volume after baking. X-ray tomography indicated a lower fragmentation index (i.e. a more connected solid structure) in the oleogel-incorporated muffins, which was correlated with more enclosed and isolated air cells. A stress relaxation test showed that the shortening replacement with oleogels produced muffins with a firmer and springier texture. Based on fatty acid compositions, the ratio of saturated to unsaturated fatty acids was significantly reduced from 2.81 to 0.41. Use of the oleogels as a shortening replacer at a ratio of 1:3 by weight was effective in producing muffins with comparable quality attributes to the control with shortening. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  5. Compression and Combining Based on Channel Shortening and Rank Reduction Technique for Cooperative Wireless Sensor Networks

    Ahmed, Qasim Zeeshan

    2013-12-18

    This paper investigates and compares the performance of wireless sensor networks where sensors operate on the principles of cooperative communications. We consider a scenario where the source transmits signals to the destination with the help of L sensors. As the destination has the capacity of processing only U out of these L signals, the strongest U signals are selected while the remaining (L?U) signals are suppressed. A preprocessing block similar to channel-shortening is proposed in this contribution. However, this preprocessing block employs a rank-reduction technique instead of channel-shortening. By employing this preprocessing, we are able to decrease the computational complexity of the system without affecting the bit error rate (BER) performance. From our simulations, it can be shown that these schemes outperform the channel-shortening schemes in terms of computational complexity. In addition, the proposed schemes have a superior BER performance as compared to channel-shortening schemes when sensors employ fixed gain amplification. However, for sensors which employ variable gain amplification, a tradeoff exists in terms of BER performance between the channel-shortening and these schemes. These schemes outperform channel-shortening scheme for lower signal-to-noise ratio.

  6. Synergistic nonuniform shortening of atrial refractory period induced by autonomic stimulation.

    Takei, M; Furukawa, Y; Narita, M; Ren, L M; Karasawa, Y; Murakami, M; Chiba, S

    1991-12-01

    We investigated the nonuniform effects of autonomic nerve stimulation of the effective refractory period (ERP) of the right atrium in the anesthetized dog. Stimulation of the discrete intracardiac sympathetic nerves to the sinoatrial (SA) nodal region uniformly shortened ERPs at three sites in the right atrium after administration of atropine. Right ansa subclavia (RS) stimulation similarly shortened ERPs in the absence of atropine. Stimulation of the discrete intracardiac parasympathetic nerves to the SA nodal region (SAP stimulation) shortened ERPs of the right atrium in a nonuniform manner. Simultaneous RS and SAP stimulation additively shortened ERPs at each site and decreased sinus rate much more than SAP stimulation alone. Shortening of ERP induced by SAP stimulation was greater than that induced by RS stimulation at similar absolute changes in heart rate. These results suggest that simultaneous activation of sympathetic and parasympathetic nerves nonuniformly shortens the ERP in the right atrium as the algebraic sum of the individual responses to each stimulation. However, parasympathetics exert the principal neural control over atrial ERP.

  7. Reducing the beam current in Linac4 in pulse to pulse mode.

    Lallement, JB; CERN. Geneva. BE Department

    2009-01-01

    In order to deliver different beam intensities to users, we studied the possibility of varying the Linac4 beam current at PS Booster injection in pulse to pulse mode. This report gives the possible configurations of Linac4 Low and Medium Energy Beam Transport lines (LEBT and MEBT) that lead to a consistent current reduction.

  8. Effects of laser wavelengths and pulse energy ratio on the emission enhancement in dual pulse LIBS

    Ahmed, Rizwan; Iqbal, Javed; Baig, M Aslam

    2015-01-01

    We present new studies on the effects of laser wavelengths, pulse energy ratio and interpulse delay between two laser pulses in the collinear dual pulse configuration of laser-induced breakdown spectroscopy (LIBS) on an iron sample in air using the fundamental (1064 nm) and the second harmonics (532 nm) of Nd:YAG lasers. In the dual pulse LIBS, an optimum value of interpulse delay with an appropriate combination of laser wavelengths, and laser pulse energy ratio, yields a 30 times signal intensity enhancement in the neutral iron lines as compared with single pulse LIBS. A comparison in the spatial variations of electron temperature along the axis of the plume expansion in single and double pulse LIBS has also been studied. (letter)

  9. Delay line clipping in a scintillation camera system

    Hatch, K.F.

    1979-01-01

    The present invention provides a novel base line restoring circuit and a novel delay line clipping circuit in a scintillation camera system. Single and double delay line clipped signal waveforms are generated for increasing the operational frequency and fidelity of data detection of the camera system by base line distortion such as undershooting, overshooting, and capacitive build-up. The camera system includes a set of photomultiplier tubes and associated amplifiers which generate sequences of pulses. These pulses are pulse-height analyzed for detecting a scintillation having an energy level which falls within a predetermined energy range. Data pulses are combined to provide coordinates and energy of photopeak events. The amplifiers are biassed out of saturation over all ranges of pulse energy level and count rate. Single delay line clipping circuitry is provided for narrowing the pulse width of the decaying electrical data pulses which increase operating speed without the occurrence of data loss. (JTA)

  10. Asymmetries of the solar Ca II lines

    Heasley, J.N.

    1975-01-01

    A theoretical study of the influence of propagating acoustic pulses in the solar chromosphere upon the line profiles of the Ca II resonance and infrared triplet lines has been made. The major objective has been to explain the observed asymmetries seen in the cores of the H and K lines and to predict the temporal behavior of the infrared lines caused by passing acoustic or shock pulses. The velocities in the pulses, calculated from weak shock theory, have been included consistently in the non-LTE calculations. The results of the calculations show that these lines are very sensitive to perturbations in the background atmosphere caused by the pulses. Only minor changes in the line shapes result from including the velocities consistently in the line source function calculations. The qualitative changes in the line profiles vary markedly with the strength of the shock pulses. The observed differences in the K line profiles seen on the quiet Sun can be explained in terms of a spectrum of pulses with different wavelengths and initial amplitudes in the photosphere. (Auth.)

  11. Pulse compression by Raman induced cavity dumping

    De Rougemont, F.; Xian, D.K.; Frey, R.; Pradere, F.

    1985-01-01

    High efficiency pulse compression using Raman induced cavity dumping has been studied theoretically and experimentally. Through stimulated Raman scattering the electromagnetic energy at a primary frequency is down-converted and extracted from a storage cavity containing the Raman medium. Energy storage may be achieved either at the laser frequency by using a laser medium inside the storage cavity, or performed at a new frequency obtained through an intracavity nonlinear process. The storage cavity may be dumped passively through stimulated Raman scattering either in an oscillator or in an amplifier. All these cases have been studied by using a ruby laser as the pump source and compressed hydrogen as the Raman scatter. Results differ slightly accordingly to the technique used, but pulse shortenings higher than 10 and quantum efficiencies higher than 80% were obtained. This method could also be used with large power lasers of any wavelength from the ultraviolet to the farinfrared spectral region

  12. Investigation of laser plasma instabilities using picosecond laser pulses

    Kline, J L; Montgomery, D S; Yin, L; Flippo, K A; Shimada, T; Johnson, R P; Rose, H A; Albright, B J; Hardin, R A

    2008-01-01

    A new short-pulse version of the single-hot-spot configuration has been implemented to enhance the performance of experiments to understand Stimulated Raman Scattering. The laser pulse length was reduced from ∼200 to ∼3 ps. The reduced pulse length improves the experiment by minimizing effects such as plasma hydrodynamic evolution and ponderomotive filamentation of the interaction beam. In addition, the shortened laser pulses allow full length 2D particle-in-cell simulations of the experiments. Using the improved single-hot-spot configuration, a series of experiments to investigate kλ D scaling of SRS has been performed. Details of the experimental setup and initial results will be presented

  13. Stochastic variation in telomere shortening rate causes heterogeneity of human fibroblast replicative life span.

    Martin-Ruiz, Carmen; Saretzki, Gabriele; Petrie, Joanne; Ladhoff, Juliane; Jeyapalan, Jessie; Wei, Wenyi; Sedivy, John; von Zglinicki, Thomas

    2004-04-23

    The replicative life span of human fibroblasts is heterogeneous, with a fraction of cells senescing at every population doubling. To find out whether this heterogeneity is due to premature senescence, i.e. driven by a nontelomeric mechanism, fibroblasts with a senescent phenotype were isolated from growing cultures and clones by flow cytometry. These senescent cells had shorter telomeres than their cycling counterparts at all population doubling levels and both in mass cultures and in individual subclones, indicating heterogeneity in the rate of telomere shortening. Ectopic expression of telomerase stabilized telomere length in the majority of cells and rescued them from early senescence, suggesting a causal role of telomere shortening. Under standard cell culture conditions, there was a minor fraction of cells that showed a senescent phenotype and short telomeres despite active telomerase. This fraction increased under chronic mild oxidative stress, which is known to accelerate telomere shortening. It is possible that even high telomerase activity cannot fully compensate for telomere shortening in all cells. The data show that heterogeneity of the human fibroblast replicative life span can be caused by significant stochastic cell-to-cell variation in telomere shortening.

  14. [Effects of removable partial dentures on the quality of life in people with shortened dental arches].

    Armellini, D B; Heydecke, G; Witter, D J; Creugers, N H J

    2009-12-01

    In order to assess the enhanced value of removable partial dentures on the quality of life, patients at 2 university clinics were screened for the presence of complete or shortened dental arches. Those selected were assigned to 1 of 5 subgroups: 1) a shortened dental arch with all frontal teeth, 2) a shortened dental arch with one or more frontal diastemas, 3) a shortened dental arch with all frontal teeth, restored by a removable partial denture, 4) a shortened dental arch and several diastemas, restored by a removable partial denture, 5) a complete dental arch. The participants completed the Oral Health Impact Profile (OHIP-49) and the Short Form Health Survey (SF-36). Clinical data recorded were: whether any teeth were missing and if so which, whether or not these had been replaced by a removable partial denture, and the number of occluding pairs of (pre)molars. The results revealed that a shortenend dental arch has a certain impact on the quality of life. However, the participants only experienced benefits from a removable partial denture if the denture also replaced frontal teeth.

  15. Crustal balance and crustal flux from shortening estimates in the Central Andes

    Hindle, David; Kley, Jonas; Oncken, Onno; Sobolev, Stephan

    2005-01-01

    The Central Andes of South America form the second largest high elevation plateau on earth. Extreme elevations have formed on a noncollisional margin with abundant associated arc magmatism. It has long been thought that the crustal thickness necessary to support Andean topography was not accounted for by known crustal shortening alone. We show that this may in part be due to a two-dimensional treatment of the problem. A three-dimensional analysis of crustal shortening and crustal thickness shows that displacement of material towards the axis of the bend in the Central Andes has added a significant volume of crust not accounted for in previous comparisons. We find that present-day crustal thickness between 12°S and 25°S is accounted for (∼-10% to ∼+3%)with the same shortening estimates, and the same assumed initial crustal thickness as had previously led to the conclusion of a ∼25-35% deficit in shortening relative to volume of crustal material. We suggest that the present-day measured crustal thickness distribution may not match that predicted due to shortening, and substantial redistribution of crust may have occurred by both erosion and deposition at the surface and lower crustal flow in regions of the thermally weakened middle and lower crust.

  16. Comparison of vegetable shortening and cocoa butter as vehicles for cortisol manipulation in Salmo trutta.

    Birnie-Gauvin, K; Peiman, K S; Larsen, M H; Aarestrup, K; Gilmour, K M; Cooke, S J

    2018-01-01

    This study demonstrates that vegetable shortening and cocoa butter are two effective vehicles for intraperitoneal cortisol implants in juvenile teleosts, specifically brown trout Salmo trutta, residing in north temperate freshwater environments. Each vehicle showed a different pattern of cortisol elevation. Vegetable shortening was found to be a more suitable vehicle for long-term cortisol elevation [elevated at 3, 6 and 9 days post treatment (dpt)], while cocoa butter may be better suited for short-term cortisol elevation (only elevated at 3 dpt). Additionally, plasma cortisol levels were higher with cortisol-vegetable shortening than with cortisol-cocoa butter implants. Plasma glucose levels were elevated 6 and 9 dpt for fishes injected with cortisol-vegetable shortening, but did not change relative to controls and shams in cortisol-cocoa butter fishes. In conclusion, vegetable shortening and cocoa butter are both viable techniques for cortisol manipulation in fishes in temperate climates, providing researchers with different options depending on study objectives. © 2017 The Fisheries Society of the British Isles.

  17. Performance of nonsynchronous noncommensurate impedance transformers in comparison to tapered line transformers

    Kim, Kseniya; Zhurbenko, Vitaliy; Johansen, Tom Keinicke

    2012-01-01

    to a traditional tapered line impedance transformer. The increase in bandwidth of nonsynchronous noncommensurate impedance transformers typically leads to shortening the transformer length, which makes the transformer attractive for applications, where a wide operating band and high transformation ratios...

  18. Simulation methods of nuclear electromagnetic pulse effects in integrated circuits

    Cheng Jili; Liu Yuan; En Yunfei; Fang Wenxiao; Wei Aixiang; Yang Yuanzhen

    2013-01-01

    In the paper the ways to compute the response of transmission line (TL) illuminated by electromagnetic pulse (EMP) were introduced firstly, which include finite-difference time-domain (FDTD) and trans-mission line matrix (TLM); then the feasibility of electromagnetic topology (EMT) in ICs nuclear electromagnetic pulse (NEMP) effect simulation was discussed; in the end, combined with the methods computing the response of TL, a new method of simulate the transmission line in IC illuminated by NEMP was put forward. (authors)

  19. Random pulse generator

    Guo Ya'nan; Jin Dapeng; Zhao Dixin; Liu Zhen'an; Qiao Qiao; Chinese Academy of Sciences, Beijing

    2007-01-01

    Due to the randomness of radioactive decay and nuclear reaction, the signals from detectors are random in time. But normal pulse generator generates periodical pulses. To measure the performances of nuclear electronic devices under random inputs, a random generator is necessary. Types of random pulse generator are reviewed, 2 digital random pulse generators are introduced. (authors)

  20. Limb shortening osteotomy in a patient with achondroplasia and leg length difference after total hip arthroplasty

    Christian L. Galata

    2013-07-01

    Full Text Available Introduction: Achondroplasia is the most common reason for disproportionate short stature. Normally, orthopedic limb lengthening procedures must be discussed in the course of this genetic disorder and have been successful in numerous achondroplastic patients in the past. In some cases, the disease may lead to leg length differences with need for surgical correction. Case Report: We report a case of achondroplastic dysplastic coxarthrosis with symptomatic leg length difference after bilateral total hip arthroplasty in a 52-year-old female patient, in which a distal femoral shortening osteotomy was successfully performed. Conclusion: Femoral shortening osteotomy is very uncommon in patients with achondroplasia. We conclude, however, that in rare cases it can be indicated and provide the advantage of shorter operation time, less perioperative complications and faster recovery compared to leg lengthening procedures. Keywords: Achondroplasia, dysplastic coxarthrosis, limb shortening, distal femur osteotomy.

  1. L-Carnosine reduces telomere damage and shortening rate in cultured normal fibroblasts

    Shao Lan; Li Qinghuan; Tan Zheng

    2004-01-01

    Telomere is the repetitive DNA sequence at the end of chromosomes, which shortens progressively with cell division and limits the replicative potential of normal human somatic cells. L-Carnosine, a naturally occurring dipeptide, has been reported to delay the replicative senescence, and extend the lifespan of cultured human diploid fibroblasts. In this work, we studied the effect of carnosine on the telomeric DNA of cultured human fetal lung fibroblast cells. Cells continuously grown in 20 mM carnosine exhibited a slower telomere shortening rate and extended lifespan in population doublings. When kept in a long-term nonproliferating state, they accumulated much less damages in the telomeric DNA when cultured in the presence of carnosine. We suggest that the reduction in telomere shortening rate and damages in telomeric DNA made an important contribution to the life-extension effect of carnosine

  2. Multiple congenital brachymetatarsia. A one-stage combined shortening and lengthening procedure without iliac bone graft.

    Kim, J S; Baek, G H; Chung, M S; Yoon, P W

    2004-09-01

    We performed nine metatarsal and three proximal phalangeal lengthenings in five patients with congenital brachymetatarsia of the first and one or two other metatarsal bones, by a one-stage combined shortening and lengthening procedure using intercalcary autogenous bone grafts from adjacent shortened metatarsal bones. Instead of the isolated lengthening of the first and the other metatarsal bones, we shortened the adjacent normal metatarsal and used the excised bone to lengthen the short toes, except for the great toe, to restore the normal parabola. One skin incision was used. All the operations were performed bilaterally and the patients were followed up for a mean period of 69.5 months (29 to 107). They all regained a nearly normal parabola and were satisfied with the cosmetic results. Our technique is straightforward and produces good cosmetic results. Satisfactory, bony union is achieved, morbidity is low, and no additional surgery is required for the removal of metal implants.

  3. Shortened Lifespan and Lethal Hemorrhage in a Hemophilia A Mouse Model.

    Staber, Janice M; Pollpeter, Molly J

    2016-01-01

    Hemophilia A animal models have helped advance our understanding of factor VIII deficiency. Previously, factor VIII deficient mouse models were reported to have a normal life span without spontaneous bleeds. However, the bleeding frequency and survival in these animals has not been thoroughly evaluated. To investigate the survival and lethal bleeding frequency in two strains of E-16 hemophilia A mice. We prospectively studied factor VIII deficient hemizygous affected males (n = 83) and homozygous affected females (n = 55) for survival and bleeding frequency. Animals were evaluated for presence and location of bleeds as potential cause of death. Hemophilia A mice had a median survival of 254 days, which is significantly shortened compared to wild type controls (p hemophilia A mice experienced hemorrhage in several tissues. This previously-underappreciated shortened survival in the hemophilia A murine model provides new outcomes for investigation of therapeutics and also reflects the shortened lifespan of patients if left untreated.

  4. Thickening the outer margins of the Tibetan Plateau: The role of crustal shortening

    Lease, R. O.; Burbank, D. W.

    2012-12-01

    One of the most direct consequences of the collision of two buoyant continents is large-scale crustal thickening that results in the upward and outward growth of high terrain. As the stronger Indian continent has collided with weaker Asia over at least the past 50 Myr, widespread crustal thickening has occurred over an area that is approximately 2.5 million km^2 at present. The resultant Tibetan crust is the thickest observed on Earth today with an average thickness of 65 km and a maximum that may reach 90 km in places. The mechanisms by which Tibetan crust has thickened, however, as well as the timing and distribution of these mechanisms across the plateau, remain debatable. Two of the most popular mechanisms for thickening the crust beneath the margins of the Tibetan Plateau are: 1) pure shear with faulting and folding in the upper crust and horizontal shortening below; and 2) flow and inflation of lower or middle crust without significant shortening of the upper crust. To help discriminate between the relative contributions of these two mechanisms, well-constrained estimates of upper crustal shortening are needed. Here we document the Cenozoic shortening budget across the northeastern Tibetan Plateau margin near 36°N 102.5°E with several 100- to 145-km-long balanced cross sections. Thermochronological and magnetostratigraphic data indicate that modest NNE-SSW shortening began in middle Eocene time, shortly after initial India-Asia collision. Accelerated east-west shortening, however, did not commence until ~35 Myr later. A five-fold acceleration in shortening rates in middle Miocene-to-Recent time accounts for more than half of the total Cenozoic crustal shortening and thickening in this region. Overall, the balanced cross sections indicate 11 ± 2 % east-west shortening since middle Miocene time, and ~9 ± 2 % NNE-SSW shortening between middle Eocene and middle Miocene times. Given the present-day crustal thickness of 56 ± 4 km in northeastern Tibet, crustal

  5. Shortening of primary operators in N-extended $SCFT_{4}$ and harmonic-superspace analyticity

    Andrianopoli, L.; Sokatchev, E.; Zupnik, B.

    1999-01-01

    We present the analysis of all possible shortenings which occur for composite gauge invariant conformal primary superfields in SU(2,2/N) invariant gauge theories. These primaries have top-spin range N/2 \\leq J_{max} < N with J_{max} = J_1 + J_2, (J_1,J_2) being the SL(2,C) quantum numbers of the highest spin component of the superfield. In Harmonic superspace, analytic and chiral superfields give J_{max}= N/2 series while intermediate shortenings correspond to fusion of chiral with analytic in N=2, or analytic with different analytic structures in N=3,4. In the AdS/CFT language shortenings of UIR's correspond to all possible BPS conditions on bulk states. An application of this analysis to multitrace operators, corresponding to multiparticle supergravity states, is spelled out.

  6. Programmable pulse generator

    Xue Zhihua; Lou Binqiao; Duan Xiaohui

    2002-01-01

    The author introduces the design of programmable pulse generator that is based on a micro-controller and controlled by RS232 interface of personal computer. The whole system has good stability. The pulse generator can produce TTL pulse and analog pulse. The pulse frequency can be selected by EPLD. The voltage amplitude and pulse width of analog pulse can be adjusted by analog switches and digitally-controlled potentiometers. The software development tools of computer is National Instruments LabView5.1. The front panel of this virtual instrumentation is intuitive and easy-to-use. Parameters can be selected and changed conveniently by knob and slide

  7. The characterisation of polymers using pulsed NMR

    Charlesby, A.

    1983-01-01

    Broad line pulsed NMR is applied to obtain information on radiation-induced polymer changes and other aspects of polymer science based on the interpretation of spin-spin relaxation curves. Calculations are made to determine the molecular weight, the crosslink density of simple, low molecular weight, flexible polymers. For higher molecular weight polymers, a conclusion can be drawn on the concentrations of entangled and crosslinked units by means of pulsed NMR. Some typical applications of the technique are illustrated by the examples of polyethylenes, rubbers, filled polymeric systems and aqueous polyethylene oxide solutions. The morphology of polymers can be followed by pulsed NMR. (V.N.)

  8. NEMP (Nuclear Electromagnetic Pulse)

    Grunow, H.K.

    The variety of measures discussed in this contribution can be used to achieve with minimum effort a damping of 10 6 :1 (120 dB) between the interfering pulses in the networks and lines outside the buildings and the lines leading to the semiconductors. Expert knowledge, experience, and insight into the systems are required to solve this task optimally. The procedure to be adopted for NEMP protection differs only slightly from that used for achieving electromagnetic compatibility and lightning protection. Industry has developed the equipment for overvoltage protection and offers graded protection systems, experienced experts and systems engineers are available. This potential of the industry could be used to sponsor a pilot project, e.g. by public research funds. One of the goals of such a project could be to work out reliable data for cost estimated for large projects. Even if one would not accept the hypothetical probability of a nuclear war as a reason good anough to start such a project, it would not be justified to deny the necessity of additional expenditure for setting up a ''NEMP emergency system'' for protection waterborne traffic on purely financial grounds. (orig./RW) [de

  9. Pulsed water jet generated by pulse multiplication

    Dvorský, R.; Sitek, Libor; Sochor, T.

    2016-01-01

    Roč. 23, č. 4 (2016), s. 959-967 ISSN 1330-3651 R&D Projects: GA MŠk(CZ) LO1406; GA MŠk ED2.1.00/03.0082 Institutional support: RVO:68145535 Keywords : high- pressure pulses * pulse intensifier * pulsed water jet * water hammer effect Subject RIV: JQ - Machines ; Tools Impact factor: 0.723, year: 2016 http://hrcak.srce.hr/163752?lang=en

  10. Acousto-optic replication of ultrashort laser pulses

    Yushkov, Konstantin B.; Molchanov, Vladimir Ya.; Ovchinnikov, Andrey V.; Chefonov, Oleg V.

    2017-10-01

    Precisely controlled sequences of ultrashort laser pulses are required in various scientific and engineering applications. We developed a phase-only acousto-optic pulse shaping method for replication of ultrashort laser pulses in a TW laser system. A sequence of several Fourier-transform-limited pulses is generated from a single femtosecond laser pulse by means of applying a piecewise linear phase modulation over the whole emission spectrum. Analysis demonstrates that the main factor which limits maximum delay between the pulse replicas is spectral resolution of the acousto-optic dispersive delay line used for pulse shaping. In experiments with a Cr:forsterite laser system, we obtained delays from 0.3 to 3.5 ps between two replicas of 190 fs transform-limited pulses at the central wavelength of laser emission, 1230 nm.

  11. 50W CW output power and 12mJ pulses from a quasi-2-level Yb:YAG ceramic rod laser end-pumped at the 969nm zero-phonon line

    Fries, Christian; Weitz, Marco; Theobald, Christian; v. Löwis of Menar, Patric; Bartschke, Jürgen; L'huillier, Johannes A.

    2015-02-01

    With the advent of high power and narrow bandwidth 969 nm pump diodes, direct pumping into the upper laser level of Yb:YAG and hence quasi-2-level lasers became possible. Pumping directly into the emitting level leads to higher quantum efficiency and reduction of non-radiative decay. Consequently, thermal load, thermal lensing and risk of fracture are reduced significantly. Moreover pump saturation and thermal population of uninvolved energy-levels in ground and excited states are benefical for a homogenous distribution of the pump beam as well as the reduction of reabsorption loss compared to 3-level systems, which allows for high-power DPSS lasers. Beside continuous-wave (cw) operation, nanosecond pulses with a repetition rate between 1 and 5 kHz are an attractive alternative to flashlamp-pumped systems (10-100 Hz) in various measurement applications that require higher data acquisition rates because of new faster detectors. Based on measurements of the absorption and a detailed numerical model for pump beam distribution, including beam propagation and saturation factors, power-scaling of a ceramic rod Yb:YAG oscillator was possible. Finally a cw output power of 50 W with 33 % pump efficiency at 1030 nm has been demonstrated (M2 dumping of this system. The cavity-dumped setup allowed for 3-10 ns pulses with a pulse energy of 12.5 mJ at 1 kHz (M2 < 1.1). In order to achieve these results a systematic experimental and numerical investigation on gain dynamics and the identification of different stable operating regimes has been carried out.

  12. Pulse shape adjustment for the SLC damping ring kickers

    Mattison, T.; Cassel, R.; Donaldson, A.; Fischer, H.; Gough, D.

    1991-05-01

    The difficulties with damping ring kickers that prevented operation of the SLAC Linear Collider in full multiple bunch mode have been overcome by shaping the current pulse to compensate for imperfections in the magnets. The risetime was improved by a peaking capacitor, with a tunable inductor to provide a locally flat pulse. The pulse was flattened by an adjustable droop inductor. Fine adjustment was provided by pulse forming line tuners driven by stepping motors. Further risetime improvement will be obtained by a saturating ferrite pulse sharpener. 4 refs., 3 figs

  13. Does Shortened Application Time Affect Long-Term Bond Strength of Universal Adhesives to Dentin?

    Saikaew, P; Matsumoto, M; Chowdhury, Afma; Carvalho, R M; Sano, H

    2018-04-09

    This study evaluated the effect of shortened application time on long-term bond strength with universal adhesives. Three universal adhesives were used: Clearfil Universal Bond (CU, Kuraray Noritake Dental Inc, Tokyo, Japan), Scotchbond Universal Adhesive (SB, 3M ESPE, St Paul, MN, USA) or G-Premio Bond (GP, GC Corp, Tokyo, Japan). Sixty molars were cut to expose midcoronal dentin and prepared with a regular diamond bur. Each adhesive was applied either according to the manufacturer's instruction or with shortened time. Specimens were stored in distilled water at 37°C for 24 hours and then cut into resin-dentin sticks. Microtensile bond strength (μTBS) was tested after either 24 hours or 1 year of water storage. Data were analyzed by the three-way ANOVA and Duncan tests ( α=0.05). Fracture modes were analyzed under a scanning electron microscope (SEM). One dentin stick per group was selected after fracture mode analysis and further observed using transmission electron microscopy (TEM). Six additional dentin discs were prepared and conditioned with each adhesive under the different application time to observe the adhesive-smear layer interaction by SEM. Shortened application time affected the μTBS ( puniversal adhesives to bur-cut dentin. The performance of universal adhesives can be compromised when applied using a shortened application time.

  14. Decayed/missing/filled teeth and shortened dental arches in Tanzanian adults.

    Sarita, P.T.N.; Witter, D.J.; Kreulen, C.M.; Matee, M.I.N.; Hof, M.A. van 't; Creugers, N.H.J.

    2004-01-01

    PURPOSE: This study assessed decayed/missing/filled teeth (DMFT), presence of occlusal units, and prevalence of shortened dental arches in a Tanzanian adult population. MATERIALS AND METHODS: The dental state of samples of the Tanzanian population was studied. Oral examinations were conducted on

  15. Shortened protocol in practical [11C]SA4503-PET studies for sigma1 receptor quantification

    Sakata, Muneyuki; Kimura, Yuichi; Ishikawa, Masatomo; Oda, Keiichi; Ishii, Kenji; Ishiwata, Kiichi; Naganawa, Mika; Hashimoto, Kenji; Chihara, Kunihiro

    2008-01-01

    In practical positron emission tomography (PET) diagnosis, a shortened protocol is preferred for patients with brain disorders. In this study, the applicability of a shortened protocol as an alternative to the 90-min PET scan with [ 11 C]SA4503 for quantitative sigma 1 receptor measurement was investigated. Tissue time-activity curves of 288 regions of interest in the brain from 32 [ 11 C]SA4503-PET scans of 16 healthy subjects prior to and following administration of a selective serotonin reuptake inhibitor (fluvoxamine or paroxetine) were applied to two algorithms of quantitative analysis; binding potential (BP) was derived from compartmental analysis based on nonlinear estimation, and total distribution volume (tDV) was derived from Logan plot analysis. As a result, although both BP and tDV tended to be underestimated by the shortened method, the estimates from the shortened protocol had good linear relationships with those of the full-length protocol. In conclusion, if approximately 10% differences in the estimated results are acceptable for a specific purpose, then a 60-min measurement protocol is capable of providing reliable results. (author)

  16. [The concentration of growth factors in patients with inherent and acquired shortenings of limbs bones].

    Strogov, M V; Luneva, S N; Novikov, K I

    2013-04-01

    The article deals with the results of study of level of growth factors in blood serum of patients with inherent and post-traumatic shortenings of limbs' bones. The detection in blood serum the level of epidermal growth factor insulin-like growth factor I and angiopoetins is proposed to monitor in given patients the reparative bone formation.

  17. The Spiritual Well-Being Scale : Psychometric Evaluation of the Shortened Version in Czech Adolescents

    Malinakova, Klara; Kopcakova, Jaroslava; Kolarcik, Peter; Geckova, Andrea Madarasova; Polackova Solcova, Iva; Husek, Vit; Kracmarova, Lucie Kluzova; Dubovska, Eva; Kalman, Michal; Puzova, Zuzana; van Dijk, Jitse P.; Tavel, Peter

    The aim of this study was to psychometrically evaluate the shortened version of the Spiritual Well-Being Scale (SWBS) in Czech adolescents. A nationally representative sample of 4217 adolescents participated in the 2014 Health Behaviour in School-aged Children survey. The internal consistency of the

  18. Matters which shorten the ozone layer; Substances qui appauvrissent la couche d'ozone

    NONE

    1999-12-01

    This document, proposed by the ministry of the national development and the environment, gives the list of the main texts relative to the matters which shorten the ozone layer and the evolution of the community regulations in this domain. The concerned matters are the Cfc and the HCFC production and use. (A.L.B.)

  19. The addition of lidocaine to bupivacaine does not shorten the duration of spinal anesthesia

    Jacobsen, Jon; Husum, Bent; Staffeldt, Henrik

    2011-01-01

    The duration of spinal anesthesia with bupivacaine is often too long for day surgery. A recent study of patients presenting for transurethral surgery suggested that the addition of a small amount of lidocaine to intrathecal hyperbaric bupivacaine could shorten the duration of the sensory and motor...

  20. Attitudes toward Seeking Professional Psychological Help: A Shortened Form and Considerations for Research.

    Fischer, Edward H.; Farina, Amerigo

    1995-01-01

    Tested a new, shortened scale for measuring willingness to seek help from mental health professionals. Scores correlated with the 29-item scale developed by Fischer and Turner (1970); the new scale's brevity (10 items) should make it easier and less obtrusive for use in research. Discusses the need for further studies on attitudes toward…

  1. Shortened carbon nanotubes and their influence on the electrical properties of polymer nanocomposites

    Inam, F.; Reece, M.J.; Peijs, A.A.J.M.

    2012-01-01

    Multi-wall carbon nanotubes of medium length (mCNTs) were aggressively tip-ultrasonicated to produce shortened and damaged carbon nanotubes (xCNTs). High-resolution electron microscopic analysis was performed to measure the dimensions of carbon nanotubes (CNTs). Thermo-gravimetric analysis and Raman

  2. Common Patterns of Congenital Lower Extremity Shortening: Diagnosis, Classification, and Follow-up.

    Bedoya, Maria A; Chauvin, Nancy A; Jaramillo, Diego; Davidson, Richard; Horn, B David; Ho-Fung, Victor

    2015-01-01

    Congenital lower limb shortening is a group of relatively rare, heterogeneous disorders. Proximal focal femoral deficiency (PFFD) and fibular hemimelia (FH) are the most common pathologic entities in this disease spectrum. PFFD is characterized by variable degrees of shortening or absence of the femoral head, with associated dysplasia of the acetabulum and femoral shaft. FH ranges from mild hypoplasia to complete absence of the fibula with variable shortening of the tibia. The development of the lower limb requires complex and precise gene interactions. Although the etiologies of PFFD and FH remain unknown, there is a strong association between the two disorders. Associated congenital defects in the lower extremity are found in more than 50% of patients with PFFD, ipsilateral FH being the most common. FH also has a strong association with shortening and bowing of the tibia and with foot deformities such as absence of the lateral rays of the foot. Early diagnosis and radiologic classification of these abnormalities are imperative for appropriate management and surgical planning. Plain radiography remains the main diagnostic imaging modality for both PFFD and FH, and appropriate description of the osseous abnormalities seen on radiographs allows accurate classification, prognostic evaluation, and surgical planning. Minor malformations may commonly be misdiagnosed. ©RSNA, 2015.

  3. Interlayer material transport during layer-normal shortening. Part I. The model

    Molen, I. van der

    1985-01-01

    To analyse mass-transfer during deformation, the case is considered of a multilayer experiencing a layer-normal shortening that is volume constant on the scale of many layers. Strain rate is homogeneously distributed on the layer-scale if diffusion is absent; when transport of matter between the

  4. Telomere shortening in hematopoietic stem cell transplantation: a potential mechanism for late graft failure?

    Awaya, Norihiro; Baerlocher, Gabriela M; Manley, Thomas J; Sanders, Jean E; Mielcarek, Marco; Torok-Storb, Beverly; Lansdorp, Peter M

    2002-01-01

    Telomeres serve to maintain the structural integrity of chromosomes, yet each somatic cell division is associated with a decrease in telomere length. The cumulative decrease in telomere length can impose an upper limit for the number of cell divisions that can occur before a cell senesces. When studied in vitro with fibroblasts, this limit is referred to as the Hayflick limit and usually occurs after 40 to 80 cell doublings. In theory, a similar replicative potential in a hematopoietic stem cell could support hematopoiesis in a person for more than 100 years. However, stem cells differentiate, and the telomere length differs among chromosomes within a single cell, among cell types, and among age-matched individuals. This variation in telomere length raises the possibility that long-term hematopoiesis by transplanted stem cells could, depending on the telomere length of the engrafted stem cell and the proliferative demand to which it is subjected, reach a Hayflick limit during the life span of the patient. Although significant shortening of telomeres is reported to occur within the first year posttransplantation, as yet no evidence has indicated that this shortening is associated with marrow function. In this review, we summarize reports on telomere shortening in stem cell transplantation recipients and report 2 cases in which graft failure is associated with significant telomere shortening.

  5. Gastric wall shortening in early gastric cancer: upper gastrointestinal series and pathologic correlation

    Kim, In Jae; Choi, Chul Soon; Kim, Eun Ah; Kim, Kyu Sun; Yun, Ku Sub; Kim, Ho Chul; Bae, Sang Hun; Kang, Gu; Shin, Hyung Sik

    1995-01-01

    To investigate the causes of gastric wall shortening in early gastric cancer, upper gastrointestinal study was correlated with pathologic findings. We evaluated 41 cases (M:F = 1.7:1, average age = 49) of early gastric cancer, retrospectively. The gastric wall shortening were classified as Grade I; none, Grade II; intermediate, and Grade III; prominent. Pathologic findings such as size of lesions, depth of tumor invasion, degree of the submucosal fibrosis, degree of thickness of the submucosa and muscularis propria, and morphologic patterns of lesions including conversing mucosal folds were correlated with the degree of gastric wall shortening on upper gastrointestinal series. Submucosal fibrosis was present in 4 cases in Grade I (n = 21), 4 cases in Grade II (n = 6) and 8 cases in Grade III (n = 10). Positive conversing mucosal folds were seen in 5 cases in Grade I (n = 17), 0 case in Grade II (n = 2) and 9 cases in Grade III (n = 9). Gastric wall shortening was significantly associated with submucosal fibrosis and conversing mucosal folds of early gastric cancer. (ρ = 0.0001, and ρ = 0.02, respectively) Upper gastrointestinal finding of gastric wall protrusion in patients with early gastric cancer should not misinterprete as advanced gastric cancer since the finding could be a result of submucosal fibrosis

  6. The Spiritual Well-Being Scale: Psychometric Evaluation of the Shortened Version in Czech Adolescents

    Maliňáková, K.; Kopčáková, J.; Kolarčik, P.; Madarasová Gecková, A.; Poláčková Šolcová, Iva; Hušek, V.; Klůzová Kračmárová, L.; Dubovská, E.; Kalman, M.; Půžová, Z.; van Dijk, J.P.; Tavel, P.

    2017-01-01

    Roč. 56, č. 2 (2017), s. 697-705 ISSN 0022-4197 Institutional support: RVO:68081740 Keywords : Shortened SWBS * Adolescents * Spirituality * Religiosity * Psychometric evaluation Subject RIV: DN - Health Impact of the Environment Quality OBOR OECD: Psychology (including human - machine relations) Impact factor: 0.873, year: 2016

  7. Differential Telomere Shortening in Blood versus Arteries in an Animal Model of Type 2 Diabetes

    Samira Tajbakhsh

    2015-01-01

    Full Text Available Vascular dysfunction is an early feature of diabetic vascular disease, due to increased oxidative stress and reduced nitric oxide (NO bioavailability. This can lead to endothelial cell senescence and clinical complications such as stroke. Cells can become senescent by shortened telomeres and oxidative stress is known to accelerate telomere attrition. Sirtuin 1 (SIRT1 has been linked to vascular health by upregulating endothelial nitric oxide synthase (eNOS, suppressing oxidative stress, and attenuating telomere shortening. Accelerated leukocyte telomere attrition appears to be a feature of clinical type 2 diabetes (T2D and therefore the telomere system may be a potential therapeutic target in preventing vascular complications of T2D. However the effect of T2D on vascular telomere length is currently unknown. We hypothesized that T2D gives rise to shortened leukocyte and vascular telomeres alongside reduced vascular SIRT1 expression and increased oxidative stress. Accelerated telomere attrition was observed in circulating leukocytes, but not arteries, in T2D compared to control rats. T2D rats had blunted arterial SIRT1 and eNOS protein expression levels which were associated with reduced antioxidant defense capacity. Our findings suggest that hyperglycemia and a deficit in vascular SIRT1 per se are not sufficient to prematurely shorten vascular telomeres.

  8. Control of the electrode metal transfer by means of the welding current pulse generator

    Knyaz'kov, A.; Pustovykh, O.; Verevkin, A.; Terekhin, V.; Shachek, A.; Knyaz'kov, S.; Tyasto, A.

    2016-04-01

    The paper presents a generator of welding current pulses to transfer an electrode metal into the molten pool. A homogeneous artificial line is used to produce near rectangular pulses. The homogeneous artificial line provides the minimum heat input with in the pulse to transfer the electrode metal, and it significantly decreases the impact of disturbances affecting this transfer. The pulse frequency does not exceed 300 Hz, and the duration is 0.6 ÷ 0.9 ms.

  9. Characterization and modulation of femtosecond laser pulse

    Dorrer, Christophe

    1999-01-01

    This work brings some solutions to the characterization and control of femtosecond laser pulses. Spectral interferometry has been extensively studied; whereas this is a rather old technique, it has found new specific applications to short pulses. Several important points concerning the experimental implementation of this technique are treated. Sources of errors have been tracked and simple solutions have been found to enhance its reliability. A recently demonstrated technique for the complete characterization of short pulses has been used to characterize short pulses from Chirped Pulse Amplification Systems. This transposition of shearing interferometry to the optical frequency domain, known as Spectral Phase Interferometry for Direct Electric-field Reconstruction (SPlDER), is conceptually very interesting: for example, the inversion from the experimental data to the electric field to be characterized is completely algebraic. A reliable tool for the characterization and optimization of Chirped pulse amplification systems has been built on this principle. This is the first single-shot real-time characterization implementation of this technique. An improvement of the method has also allowed the first single-shot real-time characterization of a short pulse using a single mono-dimensional integrative detector and an algebraic inversion of the experimental data. The control of these pulses is also of prior interest. Through a collaboration with Thomson CSF-LCR, the demonstration of the use of an optically addressed light valve at the Fourier plane of a zero-dispersion line for spectral phase modulation has been made. This device allows a high-resolution control of the spectral phase of a short pulse. It is a well-adapted tool for the correction of the residual spectral phase, at the output of Chirped Pulse Amplification systems and the temporal synthesis of shaped pulses for specific experiments. (author) [fr

  10. How does ulnar shortening osteotomy influence morphologic changes in the triangular fibrocartilage complex?

    Yamanaka, Yoshiaki; Nakamura, Toshiyasu; Sato, Kazuki; Toyama, Yoshiaki

    2014-11-01

    Ulnar shortening osteotomy often is indicated for treatment of injuries to the triangular fibrocartilage complex (TFCC). However, the effect of ulnar shortening osteotomy on the changes in shape of the TFCC is unclear. In our study, quantitative evaluations were performed using MRI to clarify the effect of ulnar shortening on triangular fibrocartilage (TFC) thickness attributable to disc regeneration of the TFC and TFC angle attributable to the suspension effect of ulnar shortening on the TFC. The purposes of this study were (1) to compare preoperative and postoperative TFC thickness and TFC angle on MR images to quantitatively evaluate the effect of ulnar shortening osteotomy on disc regeneration and the suspension effect on the TFC; and (2) to assess whether changes in TFC thickness and TFC angle correlated with the Mayo wrist score. Between 1995 and 2008, 256 patients underwent ulnar shortening osteotomy for TFCC injuries. The minimum followup was 24 months (mean, 51 months; range, 24-210 months). A total of 79 patients (31%) with complete followup including preoperative and postoperative MR images and the Mayo wrist score was included in this retrospective study. Evaluation of the postoperative MR images and the Mayo wrist score were performed at the final followup. The remaining 177 patients did not undergo postoperative MRI, or they had a previous fracture, large tears of the disc proper, or were lost to followup. Two orthopaedists, one of whom performed the surgeries, measured the TFC thickness and the TFC angle on coronal MR images before and after surgery for each patient. Correlations of the percent change in the TFC thickness and the magnitude of TFC angle change with age, sex, postoperative MR images, extent of ulnar shortening, preoperative ulnar variance, and postoperative Mayo wrist score were assessed. Stepwise regression analysis showed a correlation between the percent change in TFC thickness and preoperative ulnar variance (R2=0.21; β=-0.33; 95

  11. Laser pulse stacking method

    Moses, E.I.

    1992-12-01

    A laser pulse stacking method is disclosed. A problem with the prior art has been the generation of a series of laser beam pulses where the outer and inner regions of the beams are generated so as to form radially non-synchronous pulses. Such pulses thus have a non-uniform cross-sectional area with respect to the outer and inner edges of the pulses. The present invention provides a solution by combining the temporally non-uniform pulses in a stacking effect to thus provide a more uniform temporal synchronism over the beam diameter. 2 figs.

  12. Pulse carving using nanocavity-enhanced nonlinear effects in photonic crystal Fano structures

    Bekele, Dagmawi Alemayehu; Yu, Yi; Hu, Hao

    2018-01-01

    We experimentally demonstrate the use of a photonic crystal Fano resonance for carving-out short pulses from long-duration input pulses. This is achieved by exploiting an asymmetric Fano resonance combined with carrier-induced nonlinear effects in a photonic crystal membrane structure. The use...... of a nanocavity concentrates the input field to a very small volume leading to an efficient nonlinear resonance shift that carves a short pulse out of the input pulse. Here, we demonstrate shortening of ∼500  ps and ∼100  ps long pulses to ∼30  ps and ∼20  ps pulses, respectively. Furthermore, we demonstrate...

  13. Pulse to pulse klystron diagnosis system

    Nowak, J.; Davidson, V.; Genova, L.; Johnson, R.; Reagan, D.

    1981-03-01

    This report describes a system used to study the behavior of SLAC high powered klystrons operating with a twice normal pulse width of 5 μs. At present, up to eight of the klystrons installed along the accelerator can be operated with long pulses and monitored by this system. The report will also discuss some of the recent findings and investigations

  14. Generalization of the Rabi population inversion dynamics in the sub-one-cycle pulse limit

    Doslic, N.

    2006-01-01

    We consider the population inversion in a two-level system generated by a sub-one-cycle pulse excitation. Specifically, we explore the effect that the time derivative of the pulse envelope has on the Rabi dynamics. Our analysis is based on a combination of analytical, perturbative, and nonperturbative treatments and is complemented by numerical simulations. We find a shortening of the Rabi inversion period and show that complete inversion is unobtainable under resonant, ultrashort pulse conditions. The impact of nonresonant and carrier-envelope phase-dependent effects on the dynamics of two-level and multilevel systems is studied numerically, and conditions for complete population inversion are derived

  15. Pulse Propagation on close conductors

    Dieckmann, A

    2001-01-01

    The propagation and reflection of arbitrarily shaped pulses on non-dispersive parallel conductors of finite length with user defined cross section is simulated employing the discretized telegraph equation. The geometry of the system of conductors and the presence of dielectric material determine the capacities and inductances that enter the calculation. The values of these parameters are found using an iterative Laplace equation solving procedure and confirmed for certain calculable geometries including the line charge inside a box. The evolving pulses and the resulting crosstalk can be plotted at any instant and - in the Mathematica notebook version of this report - be looked at in an animation. As an example a differential pair of microstrips as used in the ATLAS vertex detector is analysed.

  16. CAMAC-compatible differential pulse discriminator-counter

    Tselikov, I.V.

    1988-01-01

    A differential pulse discriminator-counter for a Moessbauer spectrometer is described. Input pulses are collected according to the following algorithm; a pulse is admitted into the channel depending on whether or not the preceding pulse fell into the discrimination window. The circuit does not contain delay lines to allow for the delay lines to allow for the delay of the signal from the upper-level discriminator with respect to the signal from the lower-level discriminator due to the finite rise time of the input pulses, which makes it possible to reduce the dead time of the discriminator to the actuation time of the threshold circuits. The pulse count rate is 150 MHz, the input amplitude is +/-3 V, the dead time is 6 nsec, and the delay from input to output is 14 nsec. The unit is CAMAC-compatible

  17. Rapid line scan MR angiography

    Frahm, J.; Merboldt, K.D.; Hanicke, W.; Bruhn, H.

    1987-01-01

    Direct MR angiography may be performed using line scan imaging techniques combined with presaturation of stationary spins. Thus, a single line scan echo yields a projection of vessels due to the signal from reflowing unsaturated spins. Reconstruction of an angiographic image is performed line by line at slightly incremented positions. In particular, line scan angiography is direct and fast without a sensitivity to artifacts even for high flow rates. Image resolution and field of view may be chosen without restrictions, and zoom images using enhanced gradients may be recorded without aliasing artifacts. The method is robust with respect to eddy currents and pulsatile flow. Line scan MR angiograms of phantoms, animals, and human volunteers have been recorded using 90 0 radio frequency pulses and gradient-recalled echoes

  18. Development and assessment of a shortened Quality of Life in Childhood Epilepsy Questionnaire (QOLCE-55).

    Goodwin, Shane W; Lambrinos, Anastasia I; Ferro, Mark A; Sabaz, Mark; Speechley, Kathy N

    2015-06-01

    To develop and validate a shortened version of the Quality of Life in Childhood Epilepsy Questionnaire (QOLCE). A secondary aim was to compare baseline risk factors predicting health-related quality of life (HRQoL) in children newly diagnosed with epilepsy, as identified using the original and shortened version. Data came from the Health-Related Quality of Life in Children with Epilepsy Study (HERQULES, N = 373), a multicenter prospective cohort study. Principal component analysis reduced the number of items from the original QOLCE, and factor analysis was used to assess the factor structure of the shortened version. Convergent and divergent validity was assessed by correlating the Child Health Questionnaire (CHQ) with the shortened QOLCE. Multiple regression identified risk factors at diagnosis for HRQoL at 24 months. A four-factor, higher-order, 55-item solution was obtained. A total of 21 items were removed. The final model represents functioning in four dimensions of HRQoL: Cognitive, Emotional, Social, and Physical. The shortened QOLCE demonstrated acceptable fit: Bentler's Comparative Fit Index = 0.944; Tucker-Lewis Index = 0.942; root mean square approximation = 0.058 (90% CI: 0.056-0.061); weighted root mean square residuals (WRMR) = 1.582, and excellent internal consistency (α = 0.96, subscales α > 0.80). Factor loadings were good (first-order: λ = 0.66-0.93; higher-order λ = 0.66-0.85; p QOLCE scores correlated strongly with similar subscales of the Child Health Questionnaire (ρ = 0.38-0.70) while correlating weakly with dissimilar subscales (ρ = 0.30-0.31). While controlling for HRQoL at diagnosis, predictors for better HRQoL at 24 months were the following: no cognitive problems reported (p = 0.001), better family functioning (p = 0.014), fewer family demands (p = 0.008), with an interaction between baseline HRQoL and cognitive problems (p = 0.011). Results offer initial evidence regarding reliability and validity of the proposed 55-item shortened

  19. Novel Method of Unambiguous Moving Target Detection in Pulse-Doppler Radar with Random Pulse Repetition Interval

    Liu Zhen

    2012-03-01

    Full Text Available Blind zones and ambiguities in range and velocity measurement are two important issues in traditional pulse-Doppler radar. By generating random deviations with respect to a mean Pulse Repetition Interval (PRI, this paper proposes a novel algorithm of Moving Target Detection (MTD based on the Compressed Sensing (CS theory, in which the random deviations of the PRIare converted to the Restricted Isometry Property (RIP of the observing matrix. The ambiguities of range and velocity are eliminated by designing the signal parameters. The simulation results demonstrate that this scheme has high performance of detection, and there is no ambiguity and blind zones as well. It can also shorten the coherent processing interval compared to traditional staggered PRI mode because only one pulse train is needed instead of several trains.

  20. SLAC pulsed X-ray facility

    Ipe, N. E.; McCall, R. C.; Baker, E. D.

    1986-05-01

    The Stanford Linear Accelerator Center (SLAC) operates a high energy (up to 33 GeV) linear accelerator delivering pulses up to a few microseconds wide. The pulsed nature of the electron beam creates problems in the detection and measurement of radiation both from the accelerator beam and the klystrons that provide the RF power for the accelerator. Hence, a pulsed X-ray facility has been built at SLAC mainly for the purpose of testing the response of different radiation detection instruments to pulsed radiation fields. The X-ray tube consists of an electron gun with a control grid. This provides a stream of pulsed electrons that can be accelerated towards a confined target-window. The window is made up of aluminum 0.051 cm (20 mils) thick, plated on the vacuum side with a layer of gold 0.0006 cm (1/4 mil) thick. The frequency of electron pulses can be varied by an internal pulser from 60 to 360 pulses per second with pulse widths of 360 ns to 5 ms. The pulse amplitude can be varied over a wide range of currents. An external pulser can be used to obtain other frequencies or special pulse shapes. The voltage across the gun can be varied from 0 to 100 kV. The major part of the X-ray tube is enclosed in a large walk-in-cabinet made of 1.9 cm (3/4 in) plywood and lined with 0.32 cm (1/8 in) lead to make a very versatile facility.

  1. SLAC pulsed x-ray facility

    Ipe, N.E.; McCall, R.C.; Baker, E.D.

    1986-05-01

    The Stanford Linear Accelerator Center (SLAC) operates a high energy (up to 33 GeV) linear accelerator delivering pulses up to a few microseconds wide. The pulsed nature of the electron beam creates problems in the detection and measurement of radiation both from the accelerator beam and the klystrons that provide the rf power for the accelerator. Hence, a pulsed x-ray facility has been built at SLAC mainly for the purpose of testing the response of different radiation detection instruments to pulsed radiation fields. The x-ray tube consists of an electron gun with a control grid. This provides a stream of pulsed electrons that can be accelerated towards a confined target-window. The window is made up of aluminium 0.051 cm (20 mils) thick, plated on the vacuum side with a layer of gold 0.0006 cm (1/4 mil) thick. The frequency of electron pulses can be varied by an internal pulser from 60 to 360 pulses per second with pulse widths of 360 ns to 5 μs. The pulse amplitude can be varied over a wide range of currents. An external pulser can be used to obtain other frequencies or special pulse shapes. The voltage across the gun can be varied from 0 to 100 kV. The major part of the x-ray tube is enclosed in a large walk-in-cabinet made of 1.9 cm (3/4 in) plywood and lined with 0.32 cm (1/8 in) lead to make a very versatile facility. 3 refs., 5 figs

  2. Protein degradation and post-deboning tenderization in broiler breast meat with different degrees of muscle shortening

    Deboning broiler breast fillets prior to rigor mortis negatively influences tenderness due to sarcomere shortening. The effects of sarcomere shortening on muscle protein degradation and breast meat tenderization during post-deboning aging are not well understood. The objective of this study was to m...

  3. End-systolic stress-velocity relation and circumferential fiber velocity shortening for analysing left ventricular function in mice

    Fayssoil, A. [Cardiologie, Hopital europeen Georges Pompidou, 20, rue le blanc, Paris (France)], E-mail: fayssoil2000@yahoo.fr; Renault, G. [CNRS UMR 8104, Inserm, U567, Institut Cochin, Universite Paris Descartes, Paris (France); Fougerousse, F. [Genethon, RD, Evry (France)

    2009-08-15

    Traditionally, analysing left ventricular (LV) performance relies on echocardiography by evaluating shortening fraction (SF) in mice. SF is influenced by load conditions. End-systolic stress-velocity (ESSV) relation and circumferential fiber velocity (VcF) shortening are more relevant parameters for evaluating systolic function regardless load conditions particularly in mice's models of heart failure.

  4. Influences of the pulsed power supply on corona streamer appearance

    Veldhuizen, van E.M.; Briels, T.M.P.; Grabowski, L.R.; Pemen, A.J.M.; Ebert, U.M.

    2005-01-01

    Pulsed positive corona streamers in air are studied by images obtained with an intensified CCD camera. Using a switched capacitor power supply, thin streamers are observed that branch. A power supply consisting of a 4-stage transmission line transformer gives pulses of much higher current to the

  5. Fast pulse discriminator for photon counting at high photon densities

    Benoit, R.; Pedrini, A.

    1977-03-01

    A fast tunnel diode discriminator for photon counting up to 200MHz count frequency is described. The tunnel diode is operated on its apparent I.V. characteristics displayed when the diode is driven into its oscillating region. The pulse shaper-discriminator is completely D.C. coupled in order to avoid base-line shift at high pulse rates

  6. Design of pulse transformers for PFL charging

    Rohwein, G.J.

    1979-01-01

    Air core pulse transformers powered by low voltage capacitor banks can be simple efficient systems for charging high-voltage (0.5 to 3 MV), pulse forming transmission lines (PFL) such as those used in electron and ion beam accelerators. In these applications pulse transformers must have the combined capability of high voltage endurance and high energy transfer efficiency, particularly in repetitive pulse systems where these features are of primary importance. The design of shielded, high-voltage, spiral, strip transformers which fulfill these requirements is described in this paper. Transformers of this type have been tested in three systems which operate with greater than 90% transfer efficiency and have not failed in over 10 7 shots

  7. Chirped Pulse Spectrometer Operating at 200 GHz

    Hindle, Francis; Bray, Cédric; Hickson, Kevin; Fontanari, Daniele; Mouelhi, Meriem; Cuisset, Arnaud; Mouret, Gaël; Bocquet, Robin

    2018-01-01

    The combination of electronic sources operating at high frequencies and modern microwave instrumentation has enabled the recent development of chirped pulse spectrometers for the millimetre and THz bands. This type of instrument can operate at high resolution which is particularly suited to gas-phase rotational spectroscopy. The construction of a chirped pulse spectrometer operating at 200 GHz is described in detail while attention is paid to the phase stability and the data accumulation over many cycles. Validation using carbonyl sulphide has allowed the detection limit of the instrument to be established as function of the accumulation. A large number of OCS transitions were identified using a 10-GHz chirped pulse and include the six most abundant isotopologues, the weakest line corresponding to the fundamental R(17) transition of 16O13C33S with a line strength of 4.3 × 10-26 cm-1/(molecule cm-2). The linearity of the system response for different degrees of data accumulation and transition line strength was confirmed over four orders of magnitudes. A simple analysis of the time-domain data was demonstrated to provide the line-broadening coefficient without the need for conversion by a Fourier transform. Finally, the pulse duration is discussed and optimal values are given for both Doppler-limited and collisional regimes.

  8. Twenty-channel high-voltage pulse generators

    Anan'in, P.S.; Kashirin, A.P.

    1980-01-01

    A 20-channel high-voltage pulse generator operating with a mismatched load is described. The generator contains shaping lines 20 m long made of coaxial cable, a trigatron-type discharged, and isolating plates. The channel characteristic impedance is 50 Ohm. The maximum pulse amplitude is up to 15 kV on a high-resistance load and 7.5 kV on a matched one. The pulse duration is 100 ns at a pulse rise time of 12 ns, the delay introduced by the generator is 200 +-2.5 ns. Provision is made in the control circuit for compensation of the shaped pulse and separation of a pulse reflected from the load. The reflected pulse shape and amplitude characterize load parameters. Generator tests proved its high operational reliability (after 10 5 operations no significant changes in generator performances have been observed). The generator is intended for filmless data output from spark chambers

  9. Kinetic therapy reduces complications and shortens hospital stay in patients with cardiogenic shock - a retrospective analysis.

    Simonis, Gregor; Flemming, Kerstin; Ziegs, Enrico; Haacke, Katrin; Rauwolf, Thomas; Strasser, Ruth H

    2007-03-01

    Kinetic therapy (KT) has been shown to reduce complications and to shorten hospital stay in trauma patients. Data in non-surgical patients are inconclusive, and kinetic therapy has not been tested in patients with cardiogenic shock. The present analysis compares KT with standard care in patients with cardiogenic shock. A retrospective analysis of 133 patients with cardiogenic shock admitted to 1 academic heart center was performed. Patients with standard care (SC, turning every 2 h by the staff) were compared with kinetic therapy (KT, using oscillating air-flotation beds). 68 patients with KT were compared with 65 patients with SC. Length of ventilator therapy was 11 days in KT and 18 days in SC (p=0.048). The mortality was comparable in both groups. Pneumonia occurred in 14 patients in KT and 39 patients in SC (ppatients treated with kinetic therapy. The use of KT shortens hospital stay and reduces rates of pneumonia and pressure ulcers as compared to SC.

  10. Transitory endolymph leakage induced hearing loss and tinnitus: depolarization, biphasic shortening and loss of electromotility of outer hair cells

    Zenner, H. P.; Reuter, G.; Zimmermann, U.; Gitter, A. H.; Fermin, C.; LePage, E. L.

    1994-01-01

    There are types of deafness and tinnitus in which ruptures or massive changes in the ionic permeability of the membranes lining the endolymphatic space [e.g., of the reticular lamina (RL)] are believed to allow potassium-rich endolymph to deluge the low [K+] perilymphatic fluid (e.g., in the small spaces of Nuel). This would result in a K+ intoxication of sensory and neural structures. Acute attacks of Meniere's disease have been suggested to be an important example for this event. The present study investigated the effects of transiently elevated [K+] due to the addition of artificial endolymph to the basolateral cell surface of outer hair cells (OHC) in replicating endolymph-induced K+ intoxication of the perilymph in the small spaces of Nuel. The influence of K+ intoxication of the basolateral OHC cell surface on the transduction was then examined. Intoxication resulted in an inhibition of the physiological repolarizing K+ efflux from hair cells. This induced unwanted depolarizations of the hair cells, interfering with mechanoelectrical transduction. A pathological longitudinal OHC shortening was also found, with subsequent compression of the organ of Corti possibly influencing the micromechanics of the mechanically active OHC. Both micromechanical and electrophysiological alterations are proposed to contribute to endolymph leakage induced attacks of deafness and possibly also to tinnitus. Moreover, repeated or long-lasting K+ intoxications of OHC resulted in a chronic and complete loss of OHC motility. This is suggested to be a pathophysiological basis in some patients with chronic hearing loss resulting from Meniere's syndrome.

  11. One nanosecond pulsed electron gun systems

    Koontz, R.F.

    1979-02-01

    At SLAC there has been a continuous need for the injection of very short bunches of electrons into the accelerator. Several time-of-flight experiments have used bursts of short pulses during a normal 1.6 micro-second rf acceleration period. Single bunch beam loading experiments made use of a short pulse injection system which included high power transverse beam chopping equipment. Until the equipment described in this paper came on line, the basic grid-controlled gun pulse was limited to a rise time of 7 nanoseconds and a pulse width of 10 nanoseconds. The system described here has a grid-controlled rise time of less than 500 pico-seconds, and a minimum pulse width of less than 1 nanosecond. Pulse burst repetition rate has been demonstrated above 20 MHz during a 1.6 microsecond rf accelerating period. The order-of-magnitude increase in gun grid switching speed comes from a new gun design which minimizes lead inductance and stray capacitance, and also increases gun grid transconductance. These gun improvements coupled with a newly designed fast pulser mounted directly within the gun envelope make possible subnanosecond pulsing of the gun

  12. An 8-GW long-pulse generator based on Tesla transformer and pulse forming network.

    Su, Jiancang; Zhang, Xibo; Li, Rui; Zhao, Liang; Sun, Xu; Wang, Limin; Zeng, Bo; Cheng, Jie; Wang, Ying; Peng, Jianchang; Song, Xiaoxin

    2014-06-01

    A long-pulse generator TPG700L based on a Tesla transformer and a series pulse forming network (PFN) is constructed to generate intense electron beams for the purpose of high power microwave (HPM) generation. The TPG700L mainly consists of a 12-stage PFN, a built-in Tesla transformer in a pulse forming line, a three-electrode gas switch, a transmission line with a trigger, and a load. The Tesla transformer and the compact PFN are the key technologies for the development of the TPG700L. This generator can output electrical pulses with a width as long as 200 ns at a level of 8 GW and a repetition rate of 50 Hz. When used to drive a relative backward wave oscillator for HPM generation, the electrical pulse width is about 100 ns on a voltage level of 520 kV. Factors affecting the pulse waveform of the TPG700L are also discussed. At present, the TPG700L performs well for long-pulse HPM generation in our laboratory.

  13. An 8-GW long-pulse generator based on Tesla transformer and pulse forming network

    Su, Jiancang; Zhang, Xibo; Li, Rui; Zhao, Liang, E-mail: zhaoliang0526@163.com; Sun, Xu; Wang, Limin; Zeng, Bo; Cheng, Jie; Wang, Ying; Peng, Jianchang; Song, Xiaoxin [Science and Technology on High Power Microwave Laboratory, Northwest Institute of Nuclear Technology, Xi' an, Shaanxi 710024 (China)

    2014-06-15

    A long-pulse generator TPG700L based on a Tesla transformer and a series pulse forming network (PFN) is constructed to generate intense electron beams for the purpose of high power microwave (HPM) generation. The TPG700L mainly consists of a 12-stage PFN, a built-in Tesla transformer in a pulse forming line, a three-electrode gas switch, a transmission line with a trigger, and a load. The Tesla transformer and the compact PFN are the key technologies for the development of the TPG700L. This generator can output electrical pulses with a width as long as 200 ns at a level of 8 GW and a repetition rate of 50 Hz. When used to drive a relative backward wave oscillator for HPM generation, the electrical pulse width is about 100 ns on a voltage level of 520 kV. Factors affecting the pulse waveform of the TPG700L are also discussed. At present, the TPG700L performs well for long-pulse HPM generation in our laboratory.

  14. Diabetes mellitus as a cause of life span shortening in locally exposed rats

    Vershinina, S.F.; Markochev, A.B.

    1992-01-01

    A study was made of the development of remote radiation pathology of pancreas in male rats after local irradiation of abdomen with doses of 5, 10 (two fractions of 5 Gy at a 30-day interval) and 15 Gy (three fractions of 5 Gy at a 30-day interval). The clinical and morphological estimates show the dose-dependent development of diabetes mellitus and 1.8-fold shortening of the life span, as compared to biological control

  15. Mastication in subjects with extremely shortened dental arches rehabilitated with removable partial dentures.

    Arce-Tumbay, Jackelyn; Sanchez-Ayala, Alfonso; Sotto-Maior, Bruno Salles; Senna, Plinio Mendes; Campanha, Nara Hellen

    2011-01-01

    Mastication was evaluated in subjects presenting extremely shortened dental arches (ESDAs) rehabilitated with mandibular free-end removable partial dentures (RPDs). Subjects were divided into four groups (n = 10): those with a complete dentition, those with ESDAs, and those with ESDAs who were rehabilitated with an RPD, who were evaluated both with and without their prostheses. Mastication was measured through masticatory performance, time, and ability. RPD wearers showed higher masticatory performance (P mastication in ESDA subjects but without achieving normal mastication levels.

  16. Influence of sex on performance fatigability of the plantar flexors following repeated maximal dynamic shortening contractions.

    Lanning, Amelia C; Power, Geoffrey A; Christie, Anita D; Dalton, Brian H

    2017-10-01

    The purpose was to determine sex differences in fatigability during maximal, unconstrained velocity, shortening plantar flexions. The role of time-dependent measures (i.e., rate of torque development, rate of velocity development, and rate of neuromuscular activation) in such sex-related differences was also examined. By task termination, females exhibited smaller reductions in power and similar changes in rate of neuromuscular activation than males, indicating females were less fatigable than males.

  17. Mini-open spinal column shortening for the treatment of adult tethered cord syndrome.

    Safaee, Michael M; Winkler, Ethan A; Chou, Dean

    2017-10-01

    Tethered cord syndrome (TCS) is a challenging entity characterized by adhesions at the caudal spinal cord that prevent upward movement during growth and result in stretching of the cord with a concomitant constellation of neurologic symptoms. Although growth in height stops in adulthood, some patients still develop progressive symptoms; many underwent detethering as a child or adolescent, resulting in significant scar tissue and re-tethering. Recent strategies have focused on spinal column shortening to reduce tension on the spinal cord without exposing the previous de-tethering site. Mini-open and minimally invasive approaches avoid the large dissection and exposure associated with traditional approaches and are associated with reduced blood loss, shorter hospital stay, and similar outcomes when compared to conventional open approaches. We describe a technique for mini-open spinal column shortening. Using intraoperative navigation pedicle screws were placed at T10, T11, L1, and L2. A mini-open 3-column "egg shell" decancellation osteotomy of T12 was performed through a transpedicular approach with preservation of the superior and inferior endplates. This procedure was performed on a 28year old male with recurrent TCS and neurogenic bladder. Postoperative imaging showed a reduction in spinal column length of 1.5cm and evidence of decreased tension on the spinal cord. At last follow-up he was recovering well with improved urinary function. Spinal column shortening for adult TCS can be safely achieved through a mini-open approach. Future studies should compare the efficacy of this technique to both traditional de-tethering and open spinal column shortening. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Construction of Rate-Compatible LDPC Codes Utilizing Information Shortening and Parity Puncturing

    Jones Christopher R

    2005-01-01

    Full Text Available This paper proposes a method for constructing rate-compatible low-density parity-check (LDPC codes. The construction considers the problem of optimizing a family of rate-compatible degree distributions as well as the placement of bipartite graph edges. A hybrid approach that combines information shortening and parity puncturing is proposed. Local graph conditioning techniques for the suppression of error floors are also included in the construction methodology.

  19. The addition of lidocaine to bupivacaine does not shorten the duration of spinal anesthesia

    Jacobsen, Jon; Husum, Bent; Staffeldt, Henrik

    2011-01-01

    The duration of spinal anesthesia with bupivacaine is often too long for day surgery. A recent study of patients presenting for transurethral surgery suggested that the addition of a small amount of lidocaine to intrathecal hyperbaric bupivacaine could shorten the duration of the sensory and moto...... blocks. In this prospective, randomized double-blind study we investigated these findings in patients undergoing unilateral knee arthroscopy....

  20. Chordee and Penile Shortening Rather Than Voiding Function Are Associated With Patient Dissatisfaction After Urethroplasty.

    Maciejewski, Conrad C; Haines, Trevor; Rourke, Keith F

    2017-05-01

    To identify factors that predict patient satisfaction after urethroplasty by prospectively examining patient-reported quality of life scores using 3 validated instruments. A 3-part prospective survey consisting of the International Prostate Symptom Score (IPSS), the International Index of Erectile Function (IIEF) score, and a urethroplasty quality of life survey was completed by patients who underwent urethroplasty preoperatively and at 6 months postoperatively. The quality of life score included questions on genitourinary pain, urinary tract infection (UTI), postvoid dribbling, chordee, shortening, overall satisfaction, and overall health. Data were analyzed using descriptive statistics, paired t test, univariate and multivariate logistic regression analyses, and Wilcoxon signed-rank analysis. Patients were enrolled in the study from February 2011 to December 2014, and a total of 94 patients who underwent a total of 102 urethroplasties completed the study. Patients reported statistically significant improvements in IPSS (P Wilcoxon signed-rank analysis revealed significant improvements in pain scores (P = .02), UTI (P 4 cm and the absence of UTI, pain, shortening, and chordee as predictors of patient satisfaction. Multivariate analysis of quality of life domain scores identified absence of shortening and absence of chordee as independent predictors of patient satisfaction following urethroplasty (P < .01). Patient voiding function and quality of life improve significantly following urethroplasty, but improvement in voiding function is not associated with patient satisfaction. Chordee status and perceived penile shortening impact patient satisfaction, and should be included in patient-reported outcome measures. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. The slack test does not assess maximal shortening velocity of muscle fascicle in human.

    Hager, Robin; Dorel, Sylvain; Nordez, Antoine; Rabita, Giuseppe; Couturier, Antoine; Hauraix, Hugo; Duchateau, Jacques; Guilhem, Gaël

    2018-06-14

    The application of a series of extremely high accelerative motor-driven quick releases while muscles contract isometrically (i.e. slack test) has been proposed to assess unloaded velocity in human muscle. This study aimed to measure gastrocnemius medialis fascicle (V F ) and tendinous tissues shortening velocity during motor-driven quick releases performed at various activation levels to assess the applicability of the slack test method in human. Maximal fascicle shortening velocity and joint velocity recorded during quick releases and during fast contraction without external load (ballistic condition) were compared. Gastrocnemius medialis fascicle behaviour was investigated from 25 participants using high-frame rate ultrasound during quick releases performed at various activation levels (from 0% to 60% of maximal voluntary isometric torque) and ballistic contractions. Unloaded joint velocity calculated using the slack test method increased whereas V F decreased with muscle activation level (P≤0.03). Passive and low-level quick releases elicited higher V F values (≥ 41.4±9.7 cm.s -1 ) compared to ballistic condition (36.3±8.7 cm.s -1 ), while quick releases applied at 60% of maximal voluntary isometric torque produced the lowest V F These findings suggest that initial fascicle length, complex fascicle-tendon interactions, unloading reflex and motor-driven movement pattern strongly influence and limit the shortening velocity achieved during the slack test. Furthermore, V F elicited by quick releases is likely to reflect substantial contributions of passive processes. Therefore, the slack test is not appropriate to assess maximal muscle shortening velocity in vivo. © 2018. Published by The Company of Biologists Ltd.

  2. SHIVA star inductive pulse compression system

    Reinovsky, R.E.; Baker, W.L.; Chen, Y.G.; Holmes, J.; Lopez, E.

    1983-01-01

    The SHIVA star capacitor bank, a 120 kv parallel bank storing 9.5 mj with a short circuit current of almost 90 ma, at the AFWL is the world's highest energy, fast capacitor bank. The approximately 3 microsecond short circuit risetime is shortened by an inductive store/opening switch power conditioning system in which a total inductance of about 10 nh is charged with 35 ma currents. Electrically exploded conductor (fuse) opening switches are employed to interrupt the current in a few hundred nanoseconds to deliver a fast rising current to the load. The system is in operation at the AFWL and is used for a variety of plasma physics experiments. Performance of the bank and pulse compression system are discussed

  3. Life-shortening and carcinogenesis in mice irradiated neonatally with x rays

    Sasaki, S.; Kasuga, T.

    1981-01-01

    The characteristics of life-shortening and carcinogenesis were investigated in x-irradiated neonatal B6WFr mice. Animals were irradiated with 24 hr after birth and allowed to complete their normal life span. Mean life span was shortened linearly with doses at a rate of 9.1% per 100 R for females and 9.8% for males. The spectrum of neoplastic diseases was apparently modulated by x irradiation, showing neonatal B6WFr mice to be highly susceptible to the induction of thymic lymphoma, liver tumor, and pituitary tumor. The dose-response relationship for thymice lymphoma could be described by a linear-quadratic model, and linearity could be rejected. Thymic lymphoma developed after a short latent period, resulting in death between 100 and 450 days of age. Liver and pituitary tumors increased with increasing dose up to 400 R and decreased thereafter. The latent period for liver tumor development was apparently shortened with increasing doses. Pituitary tumor developed in excess only in females after a long latent period

  4. Telomere shortening in the colonic mucosa of patients with ulcerative colitis.

    Kinouchi, Y; Hiwatashi, N; Chida, M; Nagashima, F; Takagi, S; Maekawa, H; Toyota, T

    1998-06-01

    Telomere length in human somatic cells gradually decreases with the number of cell divisions and is regarded as a marker of somatic cell turnover. Mucosal cells of the affected colon show rapid turnover in individuals with active ulcerative colitis (UC). Telomere length was determined by Southern blot analysis of terminal restriction fragments (TRFs) from the colonic mucosa of 17 patients with UC in remission, two of whom showed dysplasia, and 17 control subjects without colitis. For each individual, mean TRF length was compared between rectal mucosa and unaffected cecal mucosa. The mean TRF length of the rectal mucosa was significantly less than that of cecal mucosa in UC patients (7.87 +/- 0.36kb versus 8.77 +/- 0.21 kb; P = 0.0015, Wilcoxon signed rank test), whereas no significant difference was detected in the control subjects. The extent of telomere shortening was 10.6 +/- 3.35% in UC patients, compared with 0.8 +/- 0.64% in noncolitis controls (P = 0.0024, Mann-Whitney U-test). Four UC patients, two of whom had dysplasia, showed telomere shortening of more than 20% in the rectal mucosa. These observations suggest that telomere shortening in the colonic mucosa of individuals with UC may represent the history of mucosal inflammation during disease of long duration, and that it may contribute to aneuploidy in UC.

  5. Field monitoring of column shortenings in a high-rise building during construction.

    Choi, Se Woon; Kim, Yousok; Kim, Jong Moon; Park, Hyo Seon

    2013-10-24

    The automatic monitoring of shortenings of vertical members in high-rise buildings under construction is a challenging issue in the high-rise building construction field. In this study, a practical system for monitoring column shortening in a high-rise building under construction is presented. The proposed monitoring system comprises the following components: (1) a wireless sensing system and (2) the corresponding monitoring software. The wireless sensing system comprises the sensors and energy-efficient wireless sensing units (sensor nodes, master nodes, and repeater nodes), which automate the processes for measuring the strains of vertical members and transmitting the measured data to the remote server. The monitoring software enables construction administrators to monitor real-time data collected by the server via an Internet connection. The proposed monitoring system is applied to actual 66-floor and 72-floor high-rise buildings under construction. The system enables automatic and real-time measurements of the shortening of vertical members, which can result in more precise construction.

  6. Reversibility of Defective Hematopoiesis Caused by Telomere Shortening in Telomerase Knockout Mice.

    Aparna Raval

    Full Text Available Telomere shortening is common in bone marrow failure syndromes such as dyskeratosis congenita (DC, aplastic anemia (AA and myelodysplastic syndromes (MDS. However, improved knowledge of the lineage-specific consequences of telomere erosion and restoration of telomere length in hematopoietic progenitors is required to advance therapeutic approaches. We have employed a reversible murine model of telomerase deficiency to compare the dependence of erythroid and myeloid lineage differentiation on telomerase activity. Fifth generation Tert-/- (G5 Tert-/- mice with shortened telomeres have significant anemia, decreased erythroblasts and reduced hematopoietic stem cell (HSC populations associated with neutrophilia and increased myelopoiesis. Intracellular multiparameter analysis by mass cytometry showed significantly reduced cell proliferation and increased sensitivity to activation of DNA damage checkpoints in erythroid progenitors and in erythroid-biased CD150hi HSC, but not in myeloid progenitors. Strikingly, Cre-inducible reactivation of telomerase activity restored hematopoietic stem and progenitor cell (HSPC proliferation, normalized the DNA damage response, and improved red cell production and hemoglobin levels. These data establish a direct link between the loss of TERT activity, telomere shortening and defective erythropoiesis and suggest that novel strategies to restore telomerase function may have an important role in the treatment of the resulting anemia.

  7. Response of slow and fast muscle to hypothyroidism: maximal shortening velocity and myosin isoforms

    Caiozzo, V. J.; Herrick, R. E.; Baldwin, K. M.

    1992-01-01

    This study examined both the shortening velocity and myosin isoform distribution of slow- (soleus) and fast-twitch (plantaris) skeletal muscles under hypothyroid conditions. Adult female Sprague-Dawley rats were randomly assigned to one of two groups: control (n = 7) or hypothyroid (n = 7). In both muscles, the relative contents of native slow myosin (SM) and type I myosin heavy chain (MHC) increased in response to the hypothyroid treatment. The effects were such that the hypothyroid soleus muscle expressed only the native SM and type I MHC isoforms while repressing native intermediate myosin and type IIA MHC. In the plantaris, the relative content of native SM and type I MHC isoforms increased from 5 to 13% and from 4 to 10% of the total myosin pool, respectively. Maximal shortening velocity of the soleus and plantaris as measured by the slack test decreased by 32 and 19%, respectively, in response to hypothyroidism. In contrast, maximal shortening velocity as estimated by force-velocity data decreased only in the soleus (-19%). No significant change was observed for the plantaris.

  8. Accelerated telomere shortening: Tracking the lasting impact of early institutional care at the cellular level.

    Humphreys, Kathryn L; Esteves, Kyle; Zeanah, Charles H; Fox, Nathan A; Nelson, Charles A; Drury, Stacy S

    2016-12-30

    Studies examining the association between early adversity and longitudinal changes in telomere length within the same individual are rare, yet are likely to provide novel insight into the subsequent lasting effects of negative early experiences. We sought to examine the association between institutional care history and telomere shortening longitudinally across middle childhood and into adolescence. Buccal DNA was collected 2-4 times, between the ages of 6 and 15 years, in 79 children enrolled in the Bucharest Early Intervention Project (BEIP), a longitudinal study exploring the impact of early institutional rearing on child health and development. Children with a history of early institutional care (n=50) demonstrated significantly greater telomere shortening across middle childhood and adolescence compared to never institutionalized children (n=29). Among children with a history of institutional care, randomization to high quality foster care was not associated with differential telomere attrition across development. Cross-sectional analysis of children randomized to the care as usual group indicated shorter telomere length was associated with greater percent of the child's life spent in institutional care up to age 8. These results suggest that early adverse care from severe psychosocial deprivation may be embedded at the molecular genetic level through accelerated telomere shortening. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. Psychometric properties of a shortened version of the Physical Self-Concept Questionnaire (PSQ-S).

    Rodríguez-Fernández, Arantzazu; Axpe, Inge; Goñi, Alfredo

    2015-01-01

    The four-dimensional model of physical self-concept which differentiates the physical self-perceptions of ability, condition, attractiveness and strength is widely accepted. In the last two decades much research has been done on the physical self-concept and its relations with the psychological well-being/distress, anxiety disorders or Eating Behavior Disorders (EBD). To validate a shortened version of the Physical Self-Concept Questionnaire (PSQ-S) and verify its ability to discriminate between people with different levels of EBD. Responses of 1478 subjects between 13 and 21 years old to the shortened version of the PSQ were analyzed in order to check indexes of reliability and validity. Furthermore, the scores of 96 women aged 14 to 23 years old diagnosed of EBD were compared to 96 others without clinical diagnosis. The results indicate a reliability of 0.93 and confirm the tetrafactorial structure of the physical selfconcept. The highest physical self-concept is that of those without a clinical diagnosis of EBD. The Shortened-PSQ is a simple, reliable and suitable screening tool both for educational and clinical settings. It also provides a sufficient measure of physical self-concept for research purposes.

  10. Characteristics of the λ/4 transmission line resonator

    Hashimoto, Y.; Masuda, H.; Yoshida, K.; Arai, S.; Niki, K.

    1994-01-01

    Though the spiral cavity is adequate for low frequency operation, mechanical instability becomes serious for such a low frequency as 20 MHz. We have then studied how to shorten the spiral length by using λ/4 transmission line models. Four models with reduced spiral length are presented. (author)

  11. SLIA beam line design

    Petillo, J.; Chernin, D.; Kostas, C.; Mondelli, A.

    1990-01-01

    The Spiral Line Induction Accelerator (SLIA) is a multi-kiloampere compact electron accelerator. It uses linear induction accelerator modules on the straight sections of a racetrack spiral, with strong-focusing bends to recirculate the electrons. The strong focusing is provided by stellarator windings on the bends. Stellarator coils are used to provide the strong focusing on the bends. The matching of the electron beam from a diode through a series of accelerator modules and stellarator bends is a major issue in the design of this accelerator. The beam line design for a proof-of-concept SLIA experiment (10 kA, 7 MeV) to be carried out at Pulse Sciences, Inc. will be presented. The design will demonstrate beam matching from element to element in the focusing system, the design of an achromatic bend, and the requirements for avoiding collective instabilities

  12. Dyslipidemia and chronic inflammation markers are correlated with telomere length shortening in Cushing's syndrome.

    Anna Aulinas

    Full Text Available Cushing's syndrome (CS increases cardiovascular risk (CVR and adipocytokine imbalance, associated with an increased inflammatory state. Telomere length (TL shortening is a novel CVR marker, associated with inflammation biomarkers. We hypothesized that inflammatory state and higher CVR in CS might be related to TL shortening, as observed in premature aging.To evaluate relationships between TL, CVR and inflammation markers in CS.In a cross-sectional study, 77 patients with CS (14 males, 59 pituitary-, 17 adrenal- and 1 ectopic-origin; 21 active disease and 77 age-, gender-, smoking-matched controls were included. Total white blood cell TL was measured by TRF-Southern technique. Clinical data and blood samples were collected (lipids, adrenal function, glucose. Adiponectin, interleukin-6 (IL6 and C-reactive protein (CRP were available in a subgroup of patients (n=32. Correlations between TL and clinical features were examined and multiple linear regression analysis was performed to investigate potential predictors of TL.Dyslipidemic CS had shorter TL than non-dyslipidemic subjects (7328±1274 vs 7957±1137 bp, p<0.05. After adjustment for age and body mass index, cured and active CS dyslipidemic patients had shorter TL than non-dyslipidemic CS (cured: 7187±1309 vs 7868±1104; active: 7203±1262 vs 8615±1056, respectively, p<0.05. Total cholesterol and triglycerides negatively correlated with TL (r-0.279 and -0.259, respectively, p<0.05, as well as CRP and IL6 (r-0.412 and -0.441, respectively, p<0.05. No difference in TL according the presence of other individual CVR factors (hypertension, diabetes mellitus, obesity were observed in CS or in the control group. Additional TL shortening was observed in dyslipidemic obese patients who were also hypertensive, compared to those with two or less CVR factors (6956±1280 vs 7860±1180, respectively, p<0.001. Age and dyslipidemia were independent negative predictors of TL.TL is shortened in dyslipidemic CS

  13. EBFA: pulsed power for fusion

    Martin, T.H.; VanDevender, J.P.; Barr, G.W.; Johnson, D.L.

    1979-01-01

    This paper will describe the EBFA I accelerator under construction for inertial confinement fusion studies with particle beams and will update previous publications concerning particle beam fusion accelerators. Previous information included Proto I, a triggered oil insulated 1 TW accelerator; Proto II, a water insulated 10 TW accelerator; and EBFA I, a 30 TW, 1 MJ accelerator. Some modifications to the original design have occurred. A new pulse-forming-line concept has been developed which increases the flexibility of the accelerator. The major problem of vacuum interface flashover has been solved by the use of long, magnetically-insulated, transmission lines. The first production module of EBFA I has been received, assembled, and is now undergoing extensive testing. The technology is extendable to at least a factor of ten above the projected EBFA capabilities of 30 TW and 1 MJ output. Progress on facilities associated with the Sandia Particle Beam fusion program is reported

  14. Experimental studies of the overshoot and undershoot in pulse-modulated radio-frequency atmospheric discharge

    Huo, W. G.; Li, R. M.; Shi, J. J. [School of Physics and Electronic Technology, Liaoning Normal University, Dalian 116029 (China); Ding, Z. F., E-mail: huowg.wg@tom.com [School of Physics and Optoelectronic Technology, Dalian University of Technology, Dalian 116023 (China)

    2016-08-15

    The overshoot and undershoot of the applied voltage on the electrodes, the discharge current, and radio frequency (RF) power were observed at the initial phase of pulse-modulated (PM) RF atmospheric pressure discharges, but factors influencing the overshoot and undershoot have not been fully elucidated. In this paper, the experimental studies were performed to seek the reasons for the overshoot and undershoot. The experimental results show that the overshoot and undershoot are associated with the pulse frequency, the rise time of pulse signal, and the series capacitor C{sub s} in the inversely L-shaped matching network. In the case of a high RF power discharge, these overshoot and undershoot become serious when shortening the rise time of a pulse signal (5 ns) or operating at a moderate pulse frequency (500 Hz or 1 kHz).

  15. Estimation of pulses in ultrasound B-scan images

    Jensen, Jørgen Arendt

    1991-01-01

    It is shown, based on an expression for the received pressure field in pulsed medical ultrasound systems, that a common one-dimensional pulse can be estimated from individual A-lines. An autoregressive moving average (ARMA) model is suggested for the pulse, and an estimator based on the prediction...... error method is derived. The estimator is used on a segment of an A-line, assuming that the pulse does not change significantly inside the segment. Several examples of the use of the estimator on synthetic data measured from a tissue phantom and in vitro data measured from a calf's liver are given....... They show that a pulse can be estimated even at moderate signal-to-noise ratios...

  16. Estimation of in-vivo pulses in medical ultrasound

    Jensen, Jørgen Arendt

    1994-01-01

    and the three-dimensional, attenuated ultrasound field for a concave transducer. Pulses are estimated from in-vivo liver data showing good resemblance to a pulse measured as the response from a planar reflector and then properly attenuated. The main application for the algorithm is to function......An algorithm for the estimation of one-dimensional in-vivo ultrasound pulses is derived. The routine estimates a set of ARMA parameters describing the pulse and uses data from a number of adjacent rf lines. Using multiple lines results in a decrease in variance on the estimated parameters...... and significantly reduces the risk of terminating the algorithm at a local minimum. Examples from use on synthetic data confirms the reduction in variance and increased chance of successful minimization termination. Simulations are also reported indicating the relation between the one-dimensional pulse...

  17. Ultrashort Laser Pulse Phenomena

    Diels, Jean-Claude

    2006-01-01

    Ultrashort Laser Pulse Phenomena, 2e serves as an introduction to the phenomena of ultra short laser pulses and describes how this technology can be used to examine problems in areas such as electromagnetism, optics, and quantum mechanics. Ultrashort Laser Pulse Phenomena combines theoretical backgrounds and experimental techniques and will serve as a manual on designing and constructing femtosecond (""faster than electronics"") systems or experiments from scratch. Beyond the simple optical system, the various sources of ultrashort pulses are presented, again with emphasis on the basic

  18. Pulsed power performance of PBFA Z

    Spielman, R.B.; Stygar, W.A.; Seamen, J.F.

    1997-01-01

    PBFA Z is a new 60-TW/5-MJ electrical driver located at Sandia National Laboratories. The authors use PBFA Z to drive z pinches. The pulsed power design of PBFA Z is based on conventional single-pulse Marx generator, water-line pulse-forming technology used on the earlier Saturn and PBFA II accelerators. PBFA Z stores 11.4 MJ in its 36 Marx generators, couples 5 MJ in a 60-TW/105-ns pulse to the output water transmission lines, and delivers 3.0 MJ and 50 TW of electrical energy to the z-pinch load. Depending on the initial load inductance and the implosion time, the authors attain peak currents of 16-20 MA with a rise time of 105 ns. Current is fed to the z-pinch load through self magnetically-insulated transmission lines (MITLs). Peak electric fields in the MITLs exceed 2 MV/cm. The current from the four independent conical-disk MITLs is combined together in a double post-hole vacuum convolute with an efficiency greater than 95%. The authors achieved x-ray powers of 200 TW and x-ray energies of 1.9 MJ from tungsten wire-array z-pinch loads

  19. High Line

    Kiib, Hans

    2015-01-01

    At just over 10 meters above street level, the High Line extends three kilometers through three districts of Southwestern Manhattan in New York. It consists of simple steel construction, and previously served as an elevated rail line connection between Penn Station on 34th Street and the many....... The High Line project has been carried out as part of an open conversion strategy. The result is a remarkable urban architectural project, which works as a catalyst for the urban development of Western Manhattan. The greater project includes the restoration and reuse of many old industrial buildings...

  20. Propagation of optical pulses in a resonantly absorbing medium: Observation of negative velocity in Rb vapor

    Tanaka, H.; Hayami, K.; Furue, S.; Nakayama, K.; Niwa, H.; Kohmoto, T.; Kunitomo, M.; Fukuda, Y.

    2003-01-01

    Propagation of optical pulses in a resonantly absorbing medium is studied. Propagation time of nanosecond pulses was measured for the Rb D 1 transition. At the center of two absorption lines, delay of the pulse peak which is about ten times as large as the pulse width was observed, where zero delay is defined for the propagation with the light velocity in vacuum. On the other hand, at the peak of an absorption line, negative delay was observed for large absorption, where the advance time is as large as 25% of the pulse width. Simulation including the effect of absorption and phase shift reproduced well the experimental results

  1. Incorporated fish oil fatty acids prevent action potential shortening induced by circulating fish oil fatty acids

    Hester M Den Ruijter

    2010-11-01

    Full Text Available Increased consumption of fatty fish, rich in omega-3 polyunsaturated fatty acids (3-PUFAs reduces the severity and number of arrhythmias. Long term 3-PUFA-intake modulates the activity of several cardiac ion channels leading to cardiac action potential shortening. Circulating 3-PUFAs in the bloodstream and incorporated 3-PUFAs in the cardiac membrane have a different mechanism to shorten the action potential. It is, however, unknown whether circulating 3-PUFAs in the bloodstream enhance or diminish the effects of incorporated 3-PUFAs. In the present study, we address this issue. Rabbits were fed a diet rich in fish oil (3 or sunflower oil (9, as control for 3 weeks. Ventricular myocytes were isolated by enzymatic dissociation and action potentials were measured using the perforated patch clamp technique in the absence and presence of acutely administered 3-PUFAs. Plasma of 3 fed rabbits contained more free eicosapentaenoic acid (EPA and isolated myocytes of 3 fed rabbits contained higher amounts of both EPA and docosahexaenoic acid (DHA in their sarcolemma compared to control. In the absence of acutely administered fatty acids, 3 myocytes had a shorter action potential with a more negative plateau than 9 myocytes. In the 9 myocytes, but not in the 3 myocytes, acute administration of a mixture of EPA+DHA shortened the action potential significantly. From these data we conclude that incorporated 3-PUFAs into the sarcolemma and acutely administered 3 fatty acids do not have a cumulative effect on action potential duration and morphology. As a consequence, patients with a high cardiac 3-PUFA status will probably not benefit from short term 3 supplementation as an antiarrhythmic therapy.

  2. Long-axis fractional shortening and mitral annulus motion in dogs

    Marlos Gonçalves Sousa

    2016-10-01

    Full Text Available Ventricular systolic dynamics involves the contraction of transverse and longitudinal myocardial fibers. Unfortunately, only the activity of the transverse myocardial fibers is foreseen by the standard systolic echocardiographic parameters. Although strain and strain rate have been used to assess the radial, circumferential and longitudinal planes of cardiac contraction, such analysis requires advanced equipment which is not always available in veterinary medicine. On the contrary, some unusual parameters may be recorded via standard methodology, allowing for the specific evaluation of left ventricular longitudinal contractility. In this study, the longitudinal contractile activity was evaluated using the long-axis fractional shortening and the mitral annulus motion, which were compared with several standard echocardiographic parameters in 14 beagles, including seven with asymptomatic mitral valve disease. The long-axis fractional shortening was positively correlated with both the mitral annulus motion and the end-diastolic left-ventricular diameter. Also, a significant correlation was found to exist between the mitral annulus motion and the left-ventricular end-diastolic diameter, which is likely supportive of its preload dependency. Even though no difference was documented in either mitral annulus motion or long-axis fractional shortening between healthy dogs and dogs with mitral valve disease, the latter only included animals with minimal cardiac remodeling, with no overt compromise of systolic function. Since it is possible to obtain these two parameters with any echocardiographic equipment, their inclusion in the routine exam would probably add information regarding the activity of the longitudinal myocardial fibers, whose functional deterioration supposedly occurs prior to the impairment of transverse fibers.

  3. Magellanic penguin telomeres do not shorten with age with increased reproductive effort, investment, and basal corticosterone.

    Cerchiara, Jack A; Risques, Rosa Ana; Prunkard, Donna; Smith, Jeffrey R; Kane, Olivia J; Boersma, P Dee

    2017-08-01

    All species should invest in systems that enhance longevity; however, a fundamental adult life-history trade-off exists between the metabolic resources allocated to maintenance and those allocated to reproduction. Long-lived species will invest more in reproduction than in somatic maintenance as they age. We investigated this trade-off by analyzing correlations among telomere length, reproductive effort and output, and basal corticosterone in Magellanic penguins ( Spheniscus magellanicus ). Telomeres shorten with age in most species studied to date, and may affect adult survival. High basal corticosterone is indicative of stressful conditions. Corticosterone, and stress, has been linked to telomere shortening in other species. Magellanic penguins are a particularly good model organism for this question as they are an unusually long-lived species, exceeding their mass-adjusted predicted lifespan by 26%. Contrary to our hypothesis, we found adults aged 5 years to over 24 years of age had similar telomere lengths. Telomeres of adults did not shorten over a 3-year period, regardless of the age of the individual. Neither telomere length, nor the rate at which the telomeres changed over these 3 years, correlated with breeding frequency or investment. Older females also produced larger volume clutches until approximately 15 years old and larger eggs produced heavier fledglings. Furthermore, reproductive success ( chicks fledged/eggs laid ) is maintained as females aged. Basal corticosterone, however, was not correlated with telomere length in adults and suggests that low basal corticosterone may play a role in the telomere maintenance we observed. Basal corticosterone also declined during the breeding season and was positively correlated with the age of adult penguins. This higher basal corticosterone in older individuals, and consistent reproductive success, supports the prediction that Magellanic penguins invest more in reproduction as they age. Our results

  4. A Possible Differentially Shortened Strike-slip Plate Boundary: the Okhotsk Plate Example.

    Hindle, D.; Egorov, V.; Mackey, K. G.; Fujita, K.

    2004-12-01

    The Okhotsk plate has been postulated based on a combination of GPS geodetic inversions (REVEL1), seimsicity, geologic and lineament data. Lying between the North American and Eurasian plates, its northwestern corner would appear to be undergoing compression in a scissors motion between the two bounding plates. Extrusion tectonics along multiple, large strike-slip faults within the Okhotsk plate itself have been suggested to allow the escape of material away from the apex of Eurasia-North America. The plate boundary between Okhotsk and North America has been suggested to be diffuse, based on widely scattered minor seismicity. However, the large, left lateral, Ulakhan fault has also been suggested as a candidate plate boundary. We present field geological and geomorphological evidence of the partitioning of deformation between the Ulakhan fault, and several parallel and oblique, linked faults. The Ulakhan fault strand appears to have a maximum displacement of 24 km based on river valley offsets and closing large pull apart basins. Some of the displacement from the Ulakhan fault appears relayed into the plate margin along oblique trending, thrust/oblique slip faults. Estimated shortening over these faults is equivalent to the amount of shortening relayed into the plate margin from the plate boundary. There may be several thrust/oblique slip faults along the Ulakhan fault, which leads to the interesting situation of a segmented, strike-slip plate boundary being actively shortened in a margin parallel direction. This may be the result of postulated extrusion of the Okhotsk plate due to North America/Eurasia convergence. Such a situation would have important consequences for the interpretation of GPS data in a plate tectonic context.

  5. Mid-term clinical outcome of radial shortening for kienbock disease

    Mohammad H Ebrahimzadeh

    2015-01-01

    Full Text Available Background: To evaluate the intermediate-term outcomes of radius shortening as a treatment for Kienbock′s disease. Materials and Methods: In a historical cohort, 16 skeletally mature patients (9 men and 7 women with Kienbock disease, who were treated with radial shortening osteotomy between 2002 and 2012, were reviewed in our study. The mean age of our patients was 30 (range 18-43 years old. According to Litchman staging, there were 7 wrists at stage II and 9 wrists at stage III (6 at stage IIIA and 3 at stage IIIB. The data of grip strength, pain (visual analog scale (VAS score, wrist range of motion (ROM, ulnar variance (according to Palmer method, and the Lichtman stage were gathered before and after surgery. We evaluated overall wrist function using the Mayo Wrist score and disabilities of the arm shoulder and hand (DASH score before surgery and at the last follow-up. Results: The average of follow-up was 7 years (range from 5 to 9 years. Preoperative ulnar variance was -1.3 mm (range from 2.5 to 1 preoperatively. The mean postoperative ulnar variance was 1 mm positive (range from 0.5 to 1.5. The VAS pain score, the mean arc of wrist flexion and extension, and grip strength improved significantly preoperatively compared to after recovery from surgery. The Lichtman stage was unchanged in nine patients, one grade worse in six patients, and one grade better in one patient. The mean DASH and Mayo scores improved significantly postoperatively compare with preoperation. Comparing preoperative positive, neuter, and negative ulnar variance, there was no significant difference in terms of VAS, DASH, and Mayo scores as well as ROM and grip strength. Conclusion: Our study shows that radius shortening surgery improves pain and disability regardless of ulnar variance.

  6. Action Potential Shortening and Impairment of Cardiac Function by Ablation of Slc26a6.

    Sirish, Padmini; Ledford, Hannah A; Timofeyev, Valeriy; Thai, Phung N; Ren, Lu; Kim, Hyo Jeong; Park, Seojin; Lee, Jeong Han; Dai, Gu; Moshref, Maryam; Sihn, Choong-Ryoul; Chen, Wei Chun; Timofeyeva, Maria Valeryevna; Jian, Zhong; Shimkunas, Rafael; Izu, Leighton T; Chiamvimonvat, Nipavan; Chen-Izu, Ye; Yamoah, Ebenezer N; Zhang, Xiao-Dong

    2017-10-01

    Intracellular pH (pH i ) is critical to cardiac excitation and contraction; uncompensated changes in pH i impair cardiac function and trigger arrhythmia. Several ion transporters participate in cardiac pH i regulation. Our previous studies identified several isoforms of a solute carrier Slc26a6 to be highly expressed in cardiomyocytes. We show that Slc26a6 mediates electrogenic Cl - /HCO 3 - exchange activities in cardiomyocytes, suggesting the potential role of Slc26a6 in regulation of not only pH i , but also cardiac excitability. To test the mechanistic role of Slc26a6 in the heart, we took advantage of Slc26a6 knockout ( Slc26a6 -/ - ) mice using both in vivo and in vitro analyses. Consistent with our prediction of its electrogenic activities, ablation of Slc26a6 results in action potential shortening. There are reduced Ca 2+ transient and sarcoplasmic reticulum Ca 2+ load, together with decreased sarcomere shortening in Slc26a6 -/ - cardiomyocytes. These abnormalities translate into reduced fractional shortening and cardiac contractility at the in vivo level. Additionally, pH i is elevated in Slc26a6 -/ - cardiomyocytes with slower recovery kinetics from intracellular alkalization, consistent with the Cl - /HCO 3 - exchange activities of Slc26a6. Moreover, Slc26a6 -/ - mice show evidence of sinus bradycardia and fragmented QRS complex, supporting the critical role of Slc26a6 in cardiac conduction system. Our study provides mechanistic insights into Slc26a6, a unique cardiac electrogenic Cl - /HCO 3 - transporter in ventricular myocytes, linking the critical roles of Slc26a6 in regulation of pH i , excitability, and contractility. pH i is a critical regulator of other membrane and contractile proteins. Future studies are needed to investigate possible changes in these proteins in Slc26a6 -/ - mice. © 2017 American Heart Association, Inc.

  7. World lines.

    Waser Jürgen; Fuchs Raphael; Ribicic Hrvoje; Schindler Benjamin; Blöschl Günther; Gröller Eduard

    2010-01-01

    In this paper we present World Lines as a novel interactive visualization that provides complete control over multiple heterogeneous simulation runs. In many application areas decisions can only be made by exploring alternative scenarios. The goal of the suggested approach is to support users in this decision making process. In this setting the data domain is extended to a set of alternative worlds where only one outcome will actually happen. World Lines integrate simulation visualization and...

  8. A Comparison of Ulnar Shortening Osteotomy Alone Versus Combined Arthroscopic Triangular Fibrocartilage Complex Debridement and Ulnar Shortening Osteotomy for Ulnar Impaction Syndrome

    Song, Hyun Seok

    2011-01-01

    Background This study compared the results of patients treated for ulnar impaction syndrome using an ulnar shortening osteotomy (USO) alone with those treated with combined arthroscopic debridement and USO. Methods The results of 27 wrists were reviewed retrospectively. They were divided into three groups: group A (USO alone, 10 cases), group B (combined arthroscopic debridement and USO, 9 cases), and group C (arthroscopic triangular fibrocartilage complex [TFCC] debridement alone, 8 cases). The wrist function was evaluated using the modified Mayo wrist score, disabilities of the arm, shoulder and hand (DASH) score and Chun and Palmer grading system. Results The modified Mayo wrist score in groups A, B, and C was 74.5 ± 8.9, 73.9 ± 11.6, and 61.3 ± 10.2, respectively (p 0.05). Conclusions Both USO alone and combined arthroscopic TFCC debridement with USO improved the wrist function and reduced the level of pain in the patients treated for ulnar impaction syndrome. USO alone may be the preferred method of treatment in patients if the torn flap of TFCC is not unstable. PMID:21909465

  9. Life shortening, tumor induction, and tissue dose for fission-neutron and gamma-ray irradiations

    Grahn, D.; Duggal, K.; Lombard, L.S.

    1985-01-01

    The primary focus of this program is to obtain information on the late effects of whole body exposure to low doses of a high linear-energy-transfer (LET) and a low-LET ionizing radiation in experimental animals to provide guidance for the prediction of radiation hazards to man. The information obtained takes the form of dose-response curves for life shortening and for the induction of numerous specific types of tumors. The animals are irradiated with fission neutrons from the Janus reactor and with 60 Co gamma rays, delivered as single, weekly, or duration-of-life exposures covering the range of doses and dose rates. 6 refs

  10. Lactose tolerance test shortened to 30 minutes: an exploratory study of its feasibility and impact

    José Luis Domínguez-Jiménez

    2014-06-01

    Full Text Available Introduction: Lactose malabsorption (LM is a very common condition with a high prevalence in our setting. Lactose tolerance test (LTT is a basic, affordable test for diagnosis that requires no complex technology. It has been recently shown that this test can be shortened to 3 measurements (baseline, 30 min, 60 min with no impact on final results. The purpose of our study was to assess the feasibility and benefits of LTT simplification and shortening to 30 min, as well as the financial impact entailed. Material and methods: A multicenter, observational study of consecutive patients undergoing LTT for LM suspicion. Patients received 50 g of lactose following a fasting period of 12 h, and had blood collected from a vein at all 3 time points for the measurement of blood glucose (mg/dl. Differences between the shortened and complete test forms were analyzed using McNemar's test. A comparison of blood glucose levels between patients with normal and abnormal results was performed using Student's T-test for independent mean values. Consistency was assessed using the kappa index. A p < 0.05 was considered to be statistically significant. Results: A total of 270 patients (69.6% females were included, with a mean age of 39.9 ± 16 years. LTT was abnormal for 151 patients (55.9%. We observed no statistically significant differences in baseline blood glucose levels between patients with normal and abnormal LTT results (p = 0.13; however, as was to be expected, such differences were obvious for the remaining time points (p < 0.01. Deleting blood glucose measurements at 60 minutes only led to overdiagnose LM (false positive results in 6 patients (2.22 %, with a kappa index of 0.95 (95% CI: 0.92-0.99 (p < 0.001 versus the complete test. Suppressing measurements at 60 min would have saved at least € 7,726. Conclusion: The shortening of LTT to only 2 measurements (baseline and 30-min hardly leads to any differences in final results, and would entail savings in

  11. Development of advanced concept for shortening construction period of ABWR plant (part 2)

    Fujita, Tomohiro; Satoh, Takashi

    2003-01-01

    The construction of the first building fully applying SC structure, which is indispensable for shortening construction period of ABWR plants (21.5 months from the first concrete work to fuel loading), has been started since August 2002 in Japan. Before the construction start, a pre-construction test with some actual size SC panels was carried out to confirm the SC modular construction method. The outline of the design and the construction of the first full-SC building and the results of the pre-construction test are reported. (author)

  12. Fast pulse beam generation systems for electron accelerators

    Koontz, R.F.

    1977-01-01

    The fast pulse beam generation system to supply the SLAC storage ring, SPEAR, by the two one nanosecond bunch electron beam pulses is described. Generation of these pulses is accomplished with a combination of a fast pulsed grided gun and a synchronized transverse beam chopper. Fast gun based on spherical cathode-grid assembly has output current up to 2As. Fast pulse amplifier system can handle trains of short pulses with repetition rates up to 40 MHz during the 1.6 μs normal accelerating time. Chopping deflector system consists of a resonant coaxial line with the deflecting plates. The resonator frequency is 39.667 MHz. A schematic diagram of the resonant system is shown. The fast beam pickup system has a one hundred picosecond rise time overrall. Fast beam generation and chopper systems permit to generate almost any short or single bunch beam profile needed for experiments

  13. Femtosecond-Laser-Pulse Characterization and Optimization for CARS Microscopy.

    Vincenzo Piazza

    Full Text Available We present a simple method and its experimental implementation to determine the pulse durations and linear chirps of the pump-and-probe pulse and the Stokes pulse in a coherent anti-Stokes Raman scattering microscope at sample level without additional autocorrelators. Our approach exploits the delay line, ubiquitous in such microscopes, to perform a convolution of the pump-and-probe and Stokes pulses as a function of their relative delay and it is based on the detection of the photons emitted from an appropriate non-linear sample. The analysis of the non-resonant four-wave-mixing and sum-frequency-generation signals allows for the direct retrieval of the pulse duration on the sample and the linear chirp of each pulse. This knowledge is crucial in maximizing the spectral-resolution and contrast in CARS imaging.

  14. Non-contrast-enhanced hepatic MR angiography: Do two-dimensional parallel imaging and short tau inversion recovery methods shorten acquisition time without image quality deterioration?

    Shimada, Kotaro, E-mail: kotaro@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University, Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Isoda, Hiroyoshi, E-mail: sayuki@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University, Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Okada, Tomohisa, E-mail: tomokada@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University, Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Kamae, Toshikazu, E-mail: toshi13@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University, Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Arizono, Shigeki, E-mail: arizono@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University, Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Hirokawa, Yuusuke, E-mail: yuusuke@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University, Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Shibata, Toshiya, E-mail: ksj@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University, Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Togashi, Kaori, E-mail: ktogashi@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University, Graduate School of Medicine, 54 Kawahara-cho, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan)

    2011-01-15

    Objective: To study whether shortening the acquisition time for selective hepatic artery visualization is feasible without image quality deterioration by adopting two-dimensional (2D) parallel imaging (PI) and short tau inversion recovery (STIR) methods. Materials and methods: Twenty-four healthy volunteers were enrolled. 3D true steady-state free-precession imaging with a time spatial labeling inversion pulse was conducted using 1D or 2D-PI and fat suppression by chemical shift selective (CHESS) or STIR methods. Three groups of different scan conditions were assigned and compared: group A (1D-PI factor 2 and CHESS), group B (2D-PI factor 2 x 2 and CHESS), and group C (2D-PI factor 2 x 2 and STIR). The artery-to-liver contrast was quantified, and the quality of artery visualization and overall image quality were scored. Results: The mean scan time was 9.5 {+-} 1.0 min (mean {+-} standard deviation), 5.9 {+-} 0.8 min, and 5.8 {+-} 0.5 min in groups A, B, and C, respectively, and was significantly shorter in groups B and C than in group A (P < 0.01). The artery-to-liver contrast was significantly better in group C than in groups A and B (P < 0.01). The scores for artery visualization and overall image quality were worse in group B than in groups A and C. The differences were statistically significant (P < 0.05) regarding the arterial branches of segments 4 and 8. Between group A and group C, which had similar scores, there were no statistically significant differences. Conclusion: Shortening the acquisition time for selective hepatic artery visualization was feasible without deterioration of the image quality by the combination of 2D-PI and STIR methods. It will facilitate using non-contrast-enhanced MRA in clinical practice.

  15. Non-contrast-enhanced hepatic MR angiography: Do two-dimensional parallel imaging and short tau inversion recovery methods shorten acquisition time without image quality deterioration?

    Shimada, Kotaro; Isoda, Hiroyoshi; Okada, Tomohisa; Kamae, Toshikazu; Arizono, Shigeki; Hirokawa, Yuusuke; Shibata, Toshiya; Togashi, Kaori

    2011-01-01

    Objective: To study whether shortening the acquisition time for selective hepatic artery visualization is feasible without image quality deterioration by adopting two-dimensional (2D) parallel imaging (PI) and short tau inversion recovery (STIR) methods. Materials and methods: Twenty-four healthy volunteers were enrolled. 3D true steady-state free-precession imaging with a time spatial labeling inversion pulse was conducted using 1D or 2D-PI and fat suppression by chemical shift selective (CHESS) or STIR methods. Three groups of different scan conditions were assigned and compared: group A (1D-PI factor 2 and CHESS), group B (2D-PI factor 2 x 2 and CHESS), and group C (2D-PI factor 2 x 2 and STIR). The artery-to-liver contrast was quantified, and the quality of artery visualization and overall image quality were scored. Results: The mean scan time was 9.5 ± 1.0 min (mean ± standard deviation), 5.9 ± 0.8 min, and 5.8 ± 0.5 min in groups A, B, and C, respectively, and was significantly shorter in groups B and C than in group A (P < 0.01). The artery-to-liver contrast was significantly better in group C than in groups A and B (P < 0.01). The scores for artery visualization and overall image quality were worse in group B than in groups A and C. The differences were statistically significant (P < 0.05) regarding the arterial branches of segments 4 and 8. Between group A and group C, which had similar scores, there were no statistically significant differences. Conclusion: Shortening the acquisition time for selective hepatic artery visualization was feasible without deterioration of the image quality by the combination of 2D-PI and STIR methods. It will facilitate using non-contrast-enhanced MRA in clinical practice.

  16. Two-stage revision of infected hip arthroplasty using a shortened post-operative course of antibiotics.

    McKenna, Paul B

    2009-04-01

    We present a series of 30 consecutive patients with 31 infected total hip arthroplasties treated by a single surgeon over a 4-year period in whom a shortened post-operative course of antimicrobial chemotherapy was used.

  17. Gas phase pulse radiolysis

    Jonah, C.D.; Andong Liu; Mulac, W.A.

    1987-01-01

    Gas phase pulse radiolysis, a technique which can be used to study many different phenomena in chemistry and physics, is discussed. As a source of small radicals, pulse radiolysis is important to the field of chemistry, particularly to combustion and atmospheric kinetics. The reactions of 1,3-butadiene, allene, ethylene and acetylene with OH are presented. 52 refs., 1 fig., 1 tab

  18. Pulse duration discriminator

    Kosakovskij, L.F.

    1980-01-01

    Basic circuits of a discriminator for discrimination of pulses with the duration greater than the preset one, and of a multifunctional discriminator allowing to discriminate pulses with the duration greater (tsub(p)>tsub(s)) and lesser (tsub(p) tsub(s) and with the duration tsub(p) [ru

  19. Sources of pulsed radiation

    Sauer, M.C. Jr.

    1981-01-01

    Characteristics of various sources of pulsed radiation are examined from the viewpoint of their importance to the radiation chemist, and some examples of uses of such sources are mentioned. A summary is given of the application of methods of physical dosimetry to pulsed sources, and the calibration of convenient chemical dosimeters by physical dosimetry is outlined. 7 figures, 1 table

  20. Pulsed neutron generator

    Bespalov, D.F.; Bykovskii, Yu.A.; Vergun, I.I.; Kozlovskii, K.I.; Kozyrev, Yu.P.; Leonov, R.K.; Simagin, B.I.; Tsybin, A.S.; Shikanov, A.Ie.

    1986-03-01

    The paper describes a new device for generating pulsed neutron fields, utilized in nuclear geophysics for carrying out pulsed neutron logging and activation analysis under field conditions. The invention employs a sealed-off neutron tube with a laser ion source which increases neutron yield to the level of 10 neutrons per second or higher. 2 refs., 1 fig

  1. Polarizing beam-splitter device at a pulsed neutron source

    Itoh, Shinichi; Takeda, Masayasu.

    1996-01-01

    A polarizing beam-splitter device was designed using Fe/Si supermirrors in order to obtain two polarized neutron beam lines, from one unpolarized neutron beam line, with a practical beam size for investigating the properties of condensed matter. This device was mounted after a guide tube at a pulsed neutron source, and its performance was investigated. (author)

  2. Comparison of hydrogenated vegetable shortening and nutritionally complete high fat diet on limited access-binge behavior in rats

    Davis, Jon F.; Melhorn, Susan J.; Heiman, Justin U.; Tschöp, Matthias H.; Clegg, Deborah J.; Benoit, Stephen C.

    2007-01-01

    Previous studies have suggested that intermittent exposure to hydrogenated vegetable shortening yields a binge/compensate pattern of feeding in rats. The present study was designed to assess whether rats would exhibit similar patterns of intake when given intermittent access to a nutritionally complete high-fat diet. Four groups of rats received varying exposure to either hydrogenated vegetable shortening or high-fat diet for 8 consecutive weeks. Animals were given daily and intermittent acce...

  3. Measurement of clavicular length and shortening after a midshaft clavicular fracture: Spatial digitization versus planar roentgen photogrammetry.

    Stegeman, Sylvia A; de Witte, Pieter Bas; Boonstra, Sjoerd; de Groot, Jurriaan H; Nagels, Jochem; Krijnen, Pieta; Schipper, Inger B

    2016-08-01

    Clavicular shortening after fracture is deemed prognostic for clinical outcome and is therefore generally assessed on radiographs. It is used for clinical decision making regarding operative or non-operative treatment in the first 2weeks after trauma, although the reliability and accuracy of the measurements are unclear. This study aimed to assess the reliability of roentgen photogrammetry (2D) of clavicular length and shortening, and to compare these with 3D-spatial digitization measurements, obtained with an electromagnetic recording system (Flock of Birds). Thirty-two participants with a consolidated non-operatively treated two or multi-fragmented dislocated midshaft clavicular fracture were analysed. Two observers measured clavicular lengths and absolute and proportional clavicular shortening on radiographs taken before and after fracture consolidation. The clavicular lengths were also measured with spatial digitization. Inter-observer agreement on the radiographic measurements was assessed using the Intraclass Correlation Coefficient (ICC). Agreement between the radiographic and spatial digitization measurements was assessed using a Bland-Altman plot. The inter-observer agreement on clavicular length, and absolute and proportional shortening on trauma radiographs was almost perfect (ICC>0.90), but moderate for absolute shortening after consolidation (ICC=0.45). The Bland-Altman plot compared measurements of length on AP panorama radiographs with spatial digitization and showed that planar roentgen photogrammetry resulted in up to 37mm longer and 34mm shorter measurements than spatial digitization. Measurements of clavicular length on radiographs are highly reliable between observers, but may not reflect the actual length and shortening of the clavicle when compared to length measurements with spatial digitization. We recommend to use proportional shortening when measuring clavicular length or shortening on radiographs for clinical decision making. Copyright

  4. Pulse induction heating

    Vasiliev, A S; Kachanov, B Y; Kogan, B V

    1993-12-31

    Induction heating and three types of pulse processes were studied. It was found that in pulse processes the frequency and pulse duration of heat treatments do not remain constant. High frequency pulse heat treatments can be used on sprayed coatings; such treatments will result in stronger surfaces with no cracks. For induction hardening, the rate of specific power was 1 to 1.5 kW/sq.cm, for forging it was 0.2 to 0.3 kW/sq.cm and for melting it was 0.05 to 0.1 kW/sq.cm. The application of pulse heating will result in higher rates of specific power.

  5. A compact high-voltage pulse generator based on pulse transformer with closed magnetic core.

    Zhang, Yu; Liu, Jinliang; Cheng, Xinbing; Bai, Guoqiang; Zhang, Hongbo; Feng, Jiahuai; Liang, Bo

    2010-03-01

    A compact high-voltage nanosecond pulse generator, based on a pulse transformer with a closed magnetic core, is presented in this paper. The pulse generator consists of a miniaturized pulse transformer, a curled parallel strip pulse forming line (PFL), a spark gap, and a matched load. The innovative design is characterized by the compact structure of the transformer and the curled strip PFL. A new structure of transformer windings was designed to keep good insulation and decrease distributed capacitance between turns of windings. A three-copper-strip structure was adopted to avoid asymmetric coupling of the curled strip PFL. When the 31 microF primary capacitor is charged to 2 kV, the pulse transformer can charge the PFL to 165 kV, and the 3.5 ohm matched load can deliver a high-voltage pulse with a duration of 9 ns, amplitude of 84 kV, and rise time of 5.1 ns. When the load is changed to 50 ohms, the output peak voltage of the generator can be 165 kV, the full width at half maximum is 68 ns, and the rise time is 6.5 ns.

  6. Pulse Distortion in Saturated Fiber Optical Parametric Chirped Pulse Amplification

    Lali-Dastjerdi, Zohreh; Da Ros, Francesco; Rottwitt, Karsten

    2012-01-01

    Fiber optical parametric chirped pulse amplification is experimentally compared for different chirped pulses in the picosecond regime. The amplified chirped pulses show distortion appearing as pedestals after recompression when the amplifier is operated in saturation.......Fiber optical parametric chirped pulse amplification is experimentally compared for different chirped pulses in the picosecond regime. The amplified chirped pulses show distortion appearing as pedestals after recompression when the amplifier is operated in saturation....

  7. On the shortening of Indian summer monsoon season in a warming scenario

    Sabeerali, C. T.; Ajayamohan, R. S.

    2018-03-01

    Assessing the future projections of the length of rainy season (LRS) has paramount societal impact considering its potential to alter the seasonal mean rainfall over the Indian subcontinent. Here, we explored the projections of LRS using both historical and Representative Concentration Pathways 8.5 (RCP8.5) simulations of the Coupled Model Intercomparison Project Phase5 (CMIP5). RCP8.5 simulations project shortening of the LRS of Indian summer monsoon by altering the timing of onset and withdrawal dates. Most CMIP5 RCP8.5 model simulations indicate a faster warming rate over the western tropical Indian Ocean compared to other regions of the Indian Ocean. It is found that the pronounced western Indian Ocean warming and associated increase in convection results in warmer upper troposphere over the Indian Ocean compared to the Indian subcontinent, reducing the meridional gradient in upper tropospheric temperature (UTT) over the Asian summer monsoon (ASM) domain. The weakening of the meridional gradient in UTT induces weakening of easterly vertical wind shear over the ASM domain during first and last phase of monsoon, facilitate delayed (advanced) monsoon onset (withdrawal) dates, ensues the shortening of LRS of the Indian summer monsoon in a warming scenario.

  8. Investigation on shortening fabrication process of instrumented irradiation capsule of JMTR

    Nagata, Hiroshi; Inoue, Shuichi; Yamaura, Takayuki; Tsuchiya, Kunihiko; Nagao, Yoshiharu

    2013-06-01

    Refurbishment of The Japan Materials Testing Reactor (JMTR) was completed in FY2010. For damage caused by the 2011 off the Pacific coast of Tohoku Earthquake, the repair of facilities was completed in October 2012. Currently, the JMTR is in preparation for restart. Irradiation tests for LWRs safety research, science and technologies and production of RI for medical diagnosis medicine, etc. are expected after the JMTR restart. On the other hand, aiming at the attractive irradiation testing reactor, the usability improvement has been discussed. As a part of the usability improvement, shortening of turnaround time to get irradiation results from an application for irradiation use was discussed focusing on the fabrication process of irradiation capsules, where the fabrication process was analyzed and reviewed by referring a trial fabrication of the mockup capsule. As a result, it was found that the turnaround time can be shortened 2 months from fabrication period of 6 months with communize of irradiation capsule parts, application of ready-made instrumentation including the sheath heater, reconsideration of inspection process, etc. (author)

  9. Mechanical versus kinematical shortening reconstructions of the Zagros High Folded Zone (Kurdistan region of Iraq)

    Frehner, Marcel; Reif, Daniel; Grasemann, Bernhard

    2012-06-01

    This paper compares kinematical and mechanical techniques for the palinspastic reconstruction of folded cross sections in collision orogens. The studied area and the reconstructed NE-SW trending, 55.5 km long cross section is located in the High Folded Zone of the Zagros fold-and-thrust belt in the Kurdistan region of Iraq. The present-day geometry of the cross section has been constructed from field as well as remote sensing data. In a first step, the structures and the stratigraphy are simplified and summarized in eight units trying to identify the main geometric and mechanical parameters. In a second step, the shortening is kinematically estimated using the dip domain method to 11%-15%. Then the same cross section is used in a numerical finite element model to perform dynamical unfolding simulations taking various rheological parameters into account. The main factor allowing for an efficient dynamic unfolding is the presence of interfacial slip conditions between the mechanically strong units. Other factors, such as Newtonian versus power law viscous rheology or the presence of a basement, affect the numerical simulations much less strongly. If interfacial slip is accounted for, fold amplitudes are reduced efficiently during the dynamical unfolding simulations, while welded layer interfaces lead to unrealistic shortening estimates. It is suggested that interfacial slip and decoupling of the deformation along detachment horizons is an important mechanical parameter that controlled the folding processes in the Zagros High Folded Zone.

  10. Shortening of an existing generic online health-related quality of life instrument for dogs.

    Reid, J; Wiseman-Orr, L; Scott, M

    2017-10-11

    Development, initial validation and reliability testing of a shortened version of a web-based questionnaire instrument to measure generic health-related quality of life in companion dogs, to facilitate smartphone and online use. The original 46 items were reduced using expert judgment and factor analysis. Items were removed on the basis of item loadings and communalities on factors identified through factor analysis of responses from owners of healthy and unwell dogs, intrafactor item correlations, readability of items in the UK, USA and Australia and ability of individual items to discriminate between healthy and unwell dogs. Validity was assessed through factor analysis and a field trial using a "known groups" approach. Test-retest reliability was assessed using intraclass correlation coefficients. The new instrument comprises 22 items, each of which was rated by dog owners using a 7-point Likert scale. Factor analysis revealed a structure with four health-related quality of life domains (energetic/enthusiastic, happy/content, active/comfortable, and calm/relaxed) accounting for 72% of the variability in the data compared with 64% for the original instrument. The field test involving 153 healthy and unwell dogs demonstrated good discriminative properties and high intraclass correlation coefficients. The 22-item shortened form is superior to the original instrument and can be accessed via a mobile phone app. This is likely to increase the acceptability to dog owners as a routine wellness measure in health care packages and as a therapeutic monitoring tool. © 2017 British Small Animal Veterinary Association.

  11. Leucocyte Telomere Shortening in relation to Newly Diagnosed Type 2 Diabetic Patients with Depression

    Zhelong Liu

    2014-01-01

    Full Text Available The goal of this study is to investigate the association between oxidative stress and telomere length shortening in the comorbid depression and diabetes. Therefore, 71 patients with newly diagnosed type 2 diabetes (T2D and 52 subjects with normal glycemic level (control, Ctrl were enrolled. Depressive status was identified with the Depression Subscale of Hospital Anxiety and Depression Scale (HADS-D. Leukocyte telomere length ratio (T/S ratio was determined with quantitative PCR. Oxidative stress status was evaluated with 8-hydroxy-desoxyguanosine (8-OHdG assay kit. Some other biochemical blood testing was also performed. The data showed that T2D patients had higher proportion of depression evaluated by the HADS-D (x2=4.196, P=0.041. T/S ratio was significantly negatively correlated with 8-OHdG, HADS-D, age, HbA1c, FPG, and HOMA-IR. In addition, HADS-D was significantly positively correlated with HbA1c, FPG, HOMA-IR, and 8-OHdG. Both HADS-D and 8-OHdG were the major independent predictors for T/S ratio. This study indicates that oxidative stress contributes to both telomere length shortening and depression development in newly diagnosed type 2 diabetic patients, while in depression status, some other mechanisms besides oxidative stress may also affect the telomere length.

  12. Increasing flux rate to shorten leaching period and ramp-up production

    Ngantung, Billy; Agustin, Riska; Ravi'i

    2017-01-01

    J Resources Bolaang Mongondow (JBRM) has operated a dynamic heap leach in its Bakan Gold Mine since late 2013. After successfully surpassing its name plate capacity of 2.6 MT/annum in 2014, the clayey and transition ore become the next operational challenge. The presence of transition and clayey ore requires longer leaching period, hence reducing the leach pad capacity which then caused reduced production. Maintaining or even increasing production with such longer leaching ore types can be done by expanding the leach pad area which means an additional capital investment, and/or shortening the leaching cycle which compromise a portion of gold extraction. JBRM has been successfully increasing the leach pad production from 2.6 MT/annum to 3.8 MT/annum, whilst improving the gold extraction from around 70% to around 80%. This was achieved by managing the operation of the leach pad which is shortening the leach cycle by identifying and combining the optimal flux rate application versus the tonne processed in each cell, at no capital investment for expanding the cell capacity.

  13. Telomere shortening is associated to TRF1 and PARP1 overexpression in Duchenne muscular dystrophy.

    Aguennouz, M'Hammed; Vita, Gian Luca; Messina, Sonia; Cama, Annamaria; Lanzano, Natalia; Ciranni, Annamaria; Rodolico, Carmelo; Di Giorgio, Rosa Maria; Vita, Giuseppe

    2011-12-01

    Telomere shortening is thought to contribute to premature senescence of satellite cells in Duchenne muscular dystrophy (DMD) muscle. Telomeric repeat binding factor-1 (TRF1) and poly (ADP-ribose) polymerase-1 (PARP1) are proteins known to modulate telomerase reverse transcriptase (TERT) activity, which controls telomere elongation. Here we show that an age-dependent telomere shortening occurs in DMD muscles and is associated to overexpression of mRNA and protein levels of TRF1 and PARP1. TERT expression and activity are detectable in normal control muscles and they slightly increase in DMD. This is the first demonstration of TRF1 and PARP1 overexpression in DMD muscles. They can be directly involved in replicative senescence of satellite cells and/or in the pathogenetic cascade through a cross-talk with oxidative stress and inflammatory response. Modulation of these events by TRF1 or PARP1 inhibition might represent a novel strategy for treatment of DMD and other muscular dystrophies. Copyright © 2010 Elsevier Inc. All rights reserved.

  14. Knowledge, perceptions and clinical application of the shortened dental arch concept among Malaysian government dentists.

    Kasim, Siti Kamilah Mohd; Razak, Ishak Abdul; Yusof, Zamros Yuzadi Mohd

    2018-02-01

    To assess the knowledge and perceptions of Malaysian government dentists regarding the shortened dental arch (SDA) concept and its application in clinical practice. The SDA concept refers to a specific type of dentition with intact anterior teeth and a reduction in posterior occlusal pairs. Dentists' knowledge and perceptions of the SDA concept can influence its application in clinical practice. A self-administered questionnaire on the SDA concept was distributed to 326 government dentists in the states of Selangor and Kuala Lumpur, Malaysia. The data were analysed using SPSS version 22 software. The response rate was 84.0%. The majority of respondents had good knowledge on five of six knowledge items and good attitudes towards 10 of 17 perception items. However, only one-fifth (20.4%) reported having applied the SDA concept in the clinic. A larger number of participants who graduated locally than who graduated abroad perceived that patients 5 years of work experience perceived that the SDA concept enables simpler treatment planning (P concept, it is not widely applied in the clinic. Concerted efforts in SDA training of dentists are needed to help to shorten denture waiting lists and reduce costs. © 2017 FDI World Dental Federation.

  15. Early telomere shortening and genomic instability in tubo-ovarian preneoplastic lesions.

    Chene, Gautier; Tchirkov, Andrei; Pierre-Eymard, Eleonore; Dauplat, Jacques; Raoelfils, Ines; Cayre, Anne; Watkin, Emmanuel; Vago, Philippe; Penault-Llorca, Frederique

    2013-06-01

    Genetic instability plays an important role in ovarian carcinogenesis. We investigated the level of telomere shortening and genomic instability in early and preinvasive stages of ovarian cancer, serous tubal intraepithelial carcinoma (STIC), and tubo-ovarian dysplasia (TOD). Fifty-one TOD from prophylactic salpingo-oophorectomies with BRCA1 or 2 mutation, 12 STICs, 53 tubo-ovarian high-grade serous carcinoma, and 36 noncancerous controls were laser capture microdissected from formalin-fixed, paraffin-embedded sections, analyzed by comparative genomic hybridization (array CGH) and for telomere length (using quantitative real-time PCR based on the Cawthon's method). TOD and STICs were defined by morphologic scores and immunohistochemical expressions of p53, Ki67, and γH2AX. TOD showed marked telomere shortening compared with noncancerous controls (P STICs had even shorter telomeres than TOD (P = 0.0008). Ovarian carcinoma had shorter telomeres than controls but longer than STICs and dysplasia. In TOD, telomeres were significantly shorter in those with BRCA1 mutation than in those with BRCA2 mutation (P = 0.005). In addition, γH2AX expression in TOD and STIC groups with short telomeres was significantly increased (P STICs. The total number of genetic alterations was the highest in ovarian cancers. These findings suggest that genetic instability occurs in early stages of ovarian tumorigenesis. STICs and noninvasive dysplasia are likely an important step in early serous ovarian neoplasia. ©2013 AACR

  16. Study of imaging time shortening in Whole Heart MRCA. Evaluation of slice thickness

    Iwai, Mitsuhiro; Tateishi, Toshiki; Takeda, Soji; Hayashi, Ryuji

    2005-01-01

    A series of examinations in cardiac MR imaging, such as cine, perfusion, MR coronary angiography (MRCA) and viability, is generally known as One Stop Cardiac Examination. It takes about 40 to 60 minutes to perform One Stop Cardiac Examination, and Whole Heart MRCA accounts for most of the examination time. Therefore, we aimed to shorten imaging time of Whole Heart MRCA, especially in a large imaging area such as that in the case of the postoperative evaluation of a bypass graft, by investigating the depiction of a diameter of mimic blood vessels as changing the slice thickness of Whole Heart MRCA. The results showed that the maximum slice thickness of about 1 mm was excellent considering the diameters of actual coronary arteries are about 3 mm. In this study, we could grasp the relationships among slice thickness of Whole Heart MRCA, the diameter of a blood vessel, and shortened examination time. We suggested that it was useful for selecting the suitable sequence depending on a patient's conditions. (author)

  17. Limiting values for the RBE of fission neutrons at low doses for life shortening in mice

    Storer, J.B.; Mitchell, T.J.

    1984-01-01

    The authors have analyzed recently published data on the effects of low doses of fission neutrons on the mean survival times of mice. The analysis for single-dose exposures was confined to doses of 20 rad or less, while for fractionated exposures only total doses of 80 rad or less were considered. They fitted the data to the frequently used power function model: life shortening = βD/sup γ/, where D is the radiation dose. They show that, at low doses per fraction, either the effects are not additive or the dose-effect curve for single exposures cannot show a greater negative curvature than about the 0.9 power of dose. Analysis of the data for γ rays showed that an exponent of 1.0 gave an acceptable fit. They conclude that at neutron doses of 20 rad or less the RBE for life shortening is constant and ranges from 13 to 22 depending on mouse strain and sex

  18. Effect of Shortened Heat Treatment on the Hardness and Microstructure of 320.0 Aluminium Alloy

    Pezda J.

    2014-06-01

    Full Text Available Improvement of Al-Si alloys properties in scope of classic method is connected with change of Si precipitations morphology through: using modification of the alloy, maintaining suitable temperature of overheating and pouring process, as well as perfection of heat treatment methods. Growing requirements of the market make it necessary to search after such procedures, which would quickly deliver positive results with simultaneous consideration of economic aspects. Presented in the paper shortened heat treatment with soaking of the alloy at temperature near temperature of solidus could be assumed as the method in the above mentioned understanding of the problem. Such treatment consists in soaking of the alloy to temperature of solutioning, keeping in such temperature, and next, quick quenching in water (20 °C followed by artificial ageing. Temperature ranges of solutioning and ageing treatments implemented in the adopted testing plan were based on analysis of recorded curves from the ATD method. Obtained results relate to dependencies and spatial diagrams describing effect of parameters of the solutioning and ageing treatments on HB hardness of the investigated alloy and change of its microstructure. Performed shortened heat treatment results in precipitation hardening of the investigated 320.0 alloy, what according to expectations produces increased hardness of the material.

  19. Lipopolysaccharide-induced inflammation attenuates taste progenitor cell proliferation and shortens the life span of taste bud cells

    Brand Joseph

    2010-06-01

    Full Text Available Abstract Background The mammalian taste bud, a complex collection of taste sensory cells, supporting cells, and immature basal cells, is the structural unit for detecting taste stimuli in the oral cavity. Even though the cells of the taste bud undergo constant turnover, the structural homeostasis of the bud is maintained by balancing cell proliferation and cell death. Compared with nongustatory lingual epithelial cells, taste cells express higher levels of several inflammatory receptors and signalling proteins. Whether inflammation, an underlying condition in some diseases associated with taste disorders, interferes with taste cell renewal and turnover is unknown. Here we report the effects of lipopolysaccharide (LPS-induced inflammation on taste progenitor cell proliferation and taste bud cell turnover in mouse taste tissues. Results Intraperitoneal injection of LPS rapidly induced expression of several inflammatory cytokines, including tumor necrosis factor (TNF-α, interferon (IFN-γ, and interleukin (IL-6, in mouse circumvallate and foliate papillae. TNF-α and IFN-γ immunoreactivities were preferentially localized to subsets of cells in taste buds. LPS-induced inflammation significantly reduced the number of 5-bromo-2'-deoxyuridine (BrdU-labeled newborn taste bud cells 1-3 days after LPS injection, suggesting an inhibition of taste bud cell renewal. BrdU pulse-chase experiments showed that BrdU-labeled taste cells had a shorter average life span in LPS-treated mice than in controls. To investigate whether LPS inhibits taste cell renewal by suppressing taste progenitor cell proliferation, we studied the expression of Ki67, a cell proliferation marker. Quantitative real-time RT-PCR revealed that LPS markedly reduced Ki67 mRNA levels in circumvallate and foliate epithelia. Immunofluorescent staining using anti-Ki67 antibodies showed that LPS decreased the number of Ki67-positive cells in the basal regions surrounding circumvallate taste buds

  20. Lipopolysaccharide-induced inflammation attenuates taste progenitor cell proliferation and shortens the life span of taste bud cells.

    Cohn, Zachary J; Kim, Agnes; Huang, Liquan; Brand, Joseph; Wang, Hong

    2010-06-10

    The mammalian taste bud, a complex collection of taste sensory cells, supporting cells, and immature basal cells, is the structural unit for detecting taste stimuli in the oral cavity. Even though the cells of the taste bud undergo constant turnover, the structural homeostasis of the bud is maintained by balancing cell proliferation and cell death. Compared with nongustatory lingual epithelial cells, taste cells express higher levels of several inflammatory receptors and signalling proteins. Whether inflammation, an underlying condition in some diseases associated with taste disorders, interferes with taste cell renewal and turnover is unknown. Here we report the effects of lipopolysaccharide (LPS)-induced inflammation on taste progenitor cell proliferation and taste bud cell turnover in mouse taste tissues. Intraperitoneal injection of LPS rapidly induced expression of several inflammatory cytokines, including tumor necrosis factor (TNF)-alpha, interferon (IFN)-gamma, and interleukin (IL)-6, in mouse circumvallate and foliate papillae. TNF-alpha and IFN-gamma immunoreactivities were preferentially localized to subsets of cells in taste buds. LPS-induced inflammation significantly reduced the number of 5-bromo-2'-deoxyuridine (BrdU)-labeled newborn taste bud cells 1-3 days after LPS injection, suggesting an inhibition of taste bud cell renewal. BrdU pulse-chase experiments showed that BrdU-labeled taste cells had a shorter average life span in LPS-treated mice than in controls. To investigate whether LPS inhibits taste cell renewal by suppressing taste progenitor cell proliferation, we studied the expression of Ki67, a cell proliferation marker. Quantitative real-time RT-PCR revealed that LPS markedly reduced Ki67 mRNA levels in circumvallate and foliate epithelia. Immunofluorescent staining using anti-Ki67 antibodies showed that LPS decreased the number of Ki67-positive cells in the basal regions surrounding circumvallate taste buds, the niche for taste progenitor

  1. Silver linings.

    Bultas, Margaret W; Pohlman, Shawn

    2014-01-01

    The purpose of this interpretive phenomenological study was to gain a better understanding of the experiences of 11 mothers of preschool children with autism spectrum disorder (ASD). Mothers were interviewed three times over a 6 week period. Interviews were analyzed using interpretive methods. This manuscript highlights one particular theme-a positive perspective mothers described as the "silver lining." This "silver lining" represents optimism despite the adversities associated with parenting a child with ASD. A deeper understanding of this side of mothering children with ASD may help health care providers improve rapport, communication, and result in more authentic family centered care. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Cusps enable line attractors for neural computation

    Xiao, Zhuocheng; Zhang, Jiwei; Sornborger, Andrew T.; Tao, Louis

    2017-01-01

    Here, line attractors in neuronal networks have been suggested to be the basis of many brain functions, such as working memory, oculomotor control, head movement, locomotion, and sensory processing. In this paper, we make the connection between line attractors and pulse gating in feed-forward neuronal networks. In this context, because of their neutral stability along a one-dimensional manifold, line attractors are associated with a time-translational invariance that allows graded information to be propagated from one neuronal population to the next. To understand how pulse-gating manifests itself in a high-dimensional, nonlinear, feedforward integrate-and-fire network, we use a Fokker-Planck approach to analyze system dynamics. We make a connection between pulse-gated propagation in the Fokker-Planck and population-averaged mean-field (firing rate) models, and then identify an approximate line attractor in state space as the essential structure underlying graded information propagation. An analysis of the line attractor shows that it consists of three fixed points: a central saddle with an unstable manifold along the line and stable manifolds orthogonal to the line, which is surrounded on either side by stable fixed points. Along the manifold defined by the fixed points, slow dynamics give rise to a ghost. We show that this line attractor arises at a cusp catastrophe, where a fold bifurcation develops as a function of synaptic noise; and that the ghost dynamics near the fold of the cusp underly the robustness of the line attractor. Understanding the dynamical aspects of this cusp catastrophe allows us to show how line attractors can persist in biologically realistic neuronal networks and how the interplay of pulse gating, synaptic coupling, and neuronal stochasticity can be used to enable attracting one-dimensional manifolds and, thus, dynamically control the processing of graded information.

  3. Cusps enable line attractors for neural computation

    Xiao, Zhuocheng; Zhang, Jiwei; Sornborger, Andrew T.; Tao, Louis

    2017-11-01

    Line attractors in neuronal networks have been suggested to be the basis of many brain functions, such as working memory, oculomotor control, head movement, locomotion, and sensory processing. In this paper, we make the connection between line attractors and pulse gating in feed-forward neuronal networks. In this context, because of their neutral stability along a one-dimensional manifold, line attractors are associated with a time-translational invariance that allows graded information to be propagated from one neuronal population to the next. To understand how pulse-gating manifests itself in a high-dimensional, nonlinear, feedforward integrate-and-fire network, we use a Fokker-Planck approach to analyze system dynamics. We make a connection between pulse-gated propagation in the Fokker-Planck and population-averaged mean-field (firing rate) models, and then identify an approximate line attractor in state space as the essential structure underlying graded information propagation. An analysis of the line attractor shows that it consists of three fixed points: a central saddle with an unstable manifold along the line and stable manifolds orthogonal to the line, which is surrounded on either side by stable fixed points. Along the manifold defined by the fixed points, slow dynamics give rise to a ghost. We show that this line attractor arises at a cusp catastrophe, where a fold bifurcation develops as a function of synaptic noise; and that the ghost dynamics near the fold of the cusp underly the robustness of the line attractor. Understanding the dynamical aspects of this cusp catastrophe allows us to show how line attractors can persist in biologically realistic neuronal networks and how the interplay of pulse gating, synaptic coupling, and neuronal stochasticity can be used to enable attracting one-dimensional manifolds and, thus, dynamically control the processing of graded information.

  4. Optical pulse compression

    Glass, A.J.

    1975-01-01

    The interest in using large lasers to achieve a very short and intense pulse for generating fusion plasma has provided a strong impetus to reexamine the possibilities of optical pulse compression at high energy. Pulse compression allows one to generate pulses of long duration (minimizing damage problems) and subsequently compress optical pulses to achieve the short pulse duration required for specific applications. The ideal device for carrying out this program has not been developed. Of the two approaches considered, the Gires--Tournois approach is limited by the fact that the bandwidth and compression are intimately related, so that the group delay dispersion times the square of the bandwidth is about unity for all simple Gires--Tournois interferometers. The Treacy grating pair does not suffer from this limitation, but is inefficient because diffraction generally occurs in several orders and is limited by the problem of optical damage to the grating surfaces themselves. Nonlinear and parametric processes were explored. Some pulse compression was achieved by these techniques; however, they are generally difficult to control and are not very efficient. (U.S.)

  5. RF Pulsed Heating

    Pritzkau, David P.

    2002-01-03

    RF pulsed heating is a process by which a metal is heated from magnetic fields on its surface due to high-power pulsed RF. When the thermal stresses induced are larger than the elastic limit, microcracks and surface roughening will occur due to cyclic fatigue. Pulsed heating limits the maximum magnetic field on the surface and through it the maximum achievable accelerating gradient in a normal conducting accelerator structure. An experiment using circularly cylindrical cavities operating in the TE{sub 011} mode at a resonant frequency of 11.424 GHz is designed to study pulsed heating on OFE copper, a material commonly used in normal conducting accelerator structures. The high-power pulsed RF is supplied by an X-band klystron capable of outputting 50 MW, 1.5 {micro}s pulses. The test pieces of the cavity are designed to be removable to allow testing of different materials with different surface preparations. A diagnostic tool is developed to measure the temperature rise in the cavity utilizing the dynamic Q change of the resonant mode due to heating. The diagnostic consists of simultaneously exciting a TE{sub 012} mode to steady-state in the cavity at 18 GHz and measuring the change in reflected power as the cavity is heated from high-power pulsed RF. Two experimental runs were completed. One run was executed at a calculated temperature rise of 120 K for 56 x 10{sup 6} pulses. The second run was executed at a calculated temperature rise of 82 K for 86 x 10{sup 6} pulses. Scanning electron microscope pictures show extensive damage occurring in the region of maximum temperature rise on the surface of the test pieces.

  6. Considering Time in Orthophotography Production: from a General Workflow to a Shortened Workflow for a Faster Disaster Response

    Lucas, G.

    2015-08-01

    This article overall deals with production time with orthophoto imagery with medium size digital frame camera. The workflow examination follows two main parts: data acquisition and post-processing. The objectives of the research are fourfold: 1/ gathering time references for the most important steps of orthophoto production (it turned out that literature is missing on this topic); these figures are used later for total production time estimation; 2/ identifying levers for reducing orthophoto production time; 3/ building a simplified production workflow for emergency response: less exigent with accuracy and faster; and compare it to a classical workflow; 4/ providing methodical elements for the estimation of production time with a custom project. In the data acquisition part a comprehensive review lists and describes all the factors that may affect the acquisition efficiency. Using a simulation with different variables (average line length, time of the turns, flight speed) their effect on acquisition efficiency is quantitatively examined. Regarding post-processing, the time references figures were collected from the processing of a 1000 frames case study with 15 cm GSD covering a rectangular area of 447 km2; the time required to achieve each step during the production is written down. When several technical options are possible, each one is tested and time documented so as all alternatives are available. Based on a technical choice with the workflow and using the compiled time reference of the elementary steps, a total time is calculated for the post-processing of the 1000 frames. Two scenarios are compared as regards to time and accuracy. The first one follows the "normal" practices, comprising triangulation, orthorectification and advanced mosaicking methods (feature detection, seam line editing and seam applicator); the second is simplified and make compromise over positional accuracy (using direct geo-referencing) and seamlines preparation in order to achieve

  7. Dynamic pulse difference circuit

    Erickson, G.L.

    1978-01-01

    A digital electronic circuit of especial use for subtracting background activity pulses in gamma spectrometry is disclosed which comprises an up-down counter connected to count up with signal-channel pulses and to count down with background-channel pulses. A detector responsive to the count position of the up-down counter provides a signal when the up-down counter has completed one scaling sequence cycle of counts in the up direction. In an alternate embodiment, a detector responsive to the count position of the up-down counter provides a signal upon overflow of the counter

  8. Coaxial pulse matching transformer

    Ledenev, V.V.; Khimenko, L.T.

    1986-01-01

    This paper describes a coaxial pulse matching transformer with comparatively simple design, increased mechanical strength, and low stray inductance. The transformer design makes it easy to change the turns ratio. The circuit of the device and an expression for the current multiplication factor are presented; experiments confirm the efficiency of the transformer. Apparatus with a coaxial transformer for producing high-power pulsed magnetic fields is designed (current pulses of 1-10 MA into a load and a natural frequency of 100 kHz)

  9. Pulse-width discriminators

    Budyashov, Yu.G.; Grebenyuk, V.M.; Zinov, V.G.

    1978-01-01

    A pulse duration discriminator is described which is intended for processing signals from multilayer scintillators. The basic elements of the scintillator are: an input gate, a current generator, an integrating capacitor, a Schmidt trigger and an anticoincidence circuit. The basic circuit of the discriminator and its time diagrams explaining its operating are given. The discriminator is based on microcircuits. Pulse duration discrimination threshold changes continuously from 20 to 100 ns, while its amplitude threshold changes within 20 to 100 mV. The temperature instability of discrimination thresholds (both in pulse width and in amplitude) is better than 0.1 per cent/deg C

  10. Multimode pulse counter

    Natanzon, D.D.

    1982-01-01

    A pulse counter with code conversion is described. The counter is based on the integrated circuits of direct-counting devices of medium integration. The counter ensures various modes of pulse counting depending on the logical control signals: reversible, two-channel summing, one-channel summing binary, summing with ''storage'' signal code fixation without interrupting pulse counting. Arrangement of the suggested structure as a microcircuit of medium integration might contribute to reduction in the counter type nomenclature in digital families of widely used integrated circuits

  11. Pulsed atomic soliton laser

    Carr, L.D.; Brand, J.

    2004-01-01

    It is shown that simultaneously changing the scattering length of an elongated, harmonically trapped Bose-Einstein condensate from positive to negative and inverting the axial portion of the trap, so that it becomes expulsive, results in a train of self-coherent solitonic pulses. Each pulse is itself a nondispersive attractive Bose-Einstein condensate that rapidly self-cools. The axial trap functions as a waveguide. The solitons can be made robustly stable with the right choice of trap geometry, number of atoms, and interaction strength. Theoretical and numerical evidence suggests that such a pulsed atomic soliton laser can be made in present experiments

  12. DogPulse

    Skovgaard, Christoffer; Thomsen, Josephine Raun; Verdezoto, Nervo

    2015-01-01

    This paper presents DogPulse, an ambient awareness system to support the coordination of dog walking among family members at home. DogPulse augments a dog collar and leash set to activate an ambient shape-changing lamp and visualize the last time the dog was taken for a walk. The lamp gradually...... changes its form and pulsates its lights in order to keep the family members aware of the dog walking activity. We report the iterative prototyping of DogPulse, its implementation and its preliminary evaluation. Based on our initial findings, we present the limitations and lessons learned as well...

  13. REM meter for pulsed sources of neutrons

    Thorngate, J.E.; Hunt, G.F.; Rueppel, D.W.

    1980-01-01

    A rem meter was constructed specifically for measuring neutrons produced by fusion experiments for which the source pulses last 10 ms or longer. The detector is a 6 Li glass scintillator, 25.4 mm in diameter and 3.2 mm thick, surrounded by 11.5 cm of polyethylene. This detector has a sensitivity of 8.5 x 10 4 counts/mrem. The signals from this fast scintillator are shaped using a shorted delay line to produce pulses that are only 10 ns long so that dose equivalent rates up to 12 mrem/s can be measured with less than a 1% counting loss. The associated electronic circuits store detector counts only when the count rate exceeds a preset level. When the count rate returns to background, a conversion from counts to dose equivalent is made and the results are displayed. As a means of recording the number of source pulses that have occurred, a second display shows how many times the preset count rate has been exceeded. Accumulation of detector counts and readouts can also be controlled manually. The unit will display the integrated dose equilavent up to 200 mrem in 0.01 mrem steps. A pulse-height discriminator rejects gamma-ray interactions below 1 MeV, and the detector size limits the response above that energy. The instrument can be operated from an ac line or will run on rechargeable batteries for up to 12 hours

  14. Radiobiological response to ultra-short pulsed megavoltage electron beams of ultra-high pulse dose rate.

    Beyreuther, Elke; Karsch, Leonhard; Laschinsky, Lydia; Leßmann, Elisabeth; Naumburger, Doreen; Oppelt, Melanie; Richter, Christian; Schürer, Michael; Woithe, Julia; Pawelke, Jörg

    2015-08-01

    In line with the long-term aim of establishing the laser-based particle acceleration for future medical application, the radiobiological consequences of the typical ultra-short pulses and ultra-high pulse dose rate can be investigated with electron delivery. The radiation source ELBE (Electron Linac for beams with high Brilliance and low Emittance) was used to mimic the quasi-continuous electron beam of a clinical linear accelerator (LINAC) for comparison with electron pulses at the ultra-high pulse dose rate of 10(10) Gy min(-1) either at the low frequency of a laser accelerator or at 13 MHz avoiding effects of prolonged dose delivery. The impact of pulse structure was analyzed by clonogenic survival assay and by the number of residual DNA double-strand breaks remaining 24 h after irradiation of two human squamous cell carcinoma lines of differing radiosensitivity. The radiation response of both cell lines was found to be independent from electron pulse structure for the two endpoints under investigation. The results reveal, that ultra-high pulse dose rates of 10(10) Gy min(-1) and the low repetition rate of laser accelerated electrons have no statistically significant influence (within the 95% confidence intervals) on the radiobiological effectiveness of megavoltage electrons.

  15. Efficient method to design RF pulses for parallel excitation MRI using gridding and conjugate gradient.

    Feng, Shuo; Ji, Jim

    2014-04-01

    Parallel excitation (pTx) techniques with multiple transmit channels have been widely used in high field MRI imaging to shorten the RF pulse duration and/or reduce the specific absorption rate (SAR). However, the efficiency of pulse design still needs substantial improvement for practical real-time applications. In this paper, we present a detailed description of a fast pulse design method with Fourier domain gridding and a conjugate gradient method. Simulation results of the proposed method show that the proposed method can design pTx pulses at an efficiency 10 times higher than that of the conventional conjugate-gradient based method, without reducing the accuracy of the desirable excitation patterns.

  16. Rapid thermal pulse annealing

    Miller, M.G.; Koehn, B.W.; Chaplin, R.L.

    1976-01-01

    Characteristics of recovery processes have been investigated for cases of heating a sample to successively higher temperatures by means of isochronal annealing or by using a rapid pulse annealing. A recovery spectra shows the same features independent of which annealing procedure is used. In order to determine which technique provides the best resolution, a study was made of how two independent first-order processes are separated for different heating rates and time increments of the annealing pulses. It is shown that the pulse anneal method offers definite advantages over isochronal annealing when annealing for short time increments. Experimental data by means of the pulse anneal techniques are given for the various substages of stage I of aluminium. (author)

  17. Pulse holographic measurement techniques

    Kim, Cheol Jung; Baik, Seong Hoon; Hong, Seok Kyung; Kim, Jeong Moog; Kim, Duk Hyun

    1992-01-01

    With the development of laser, remote inspection techniques using laser have been growing on. The inspection and measurement techniques by pulse holography are well-established technique for precise measurement, and widely used in various fields of industry now. In nuclear industry, this technology is practically used because holographic inspection is remote, noncontact, and precise measurement technique. In relation to remote inspection technology in nuclear industry, state-of-the art of pulse HNDT (Holographic non-destructive testing) and holographic measurement techniques are examined. First of all, the fundamental principles as well as practical problems for applications are briefly described. The fields of pulse holography have been divided into the HNDT, flow visualization and distribution study, and other application techniques. Additionally holographic particle study, bubble chamber holography, and applications to other visualization techniques are described. Lastly, the current status for the researches and applications of pulse holography to nuclear industry which are carried out actively in Europe and USA, is described. (Author)

  18. IAE pulsed electrostatic accelerator

    Afanas'ev, V.P.; Ganzhelyuk, M.L.; Kozlov, L.D.; Koltypin, E.A.; Molchanov, Yu.D.; Otroshchenko, G.A.; Yan'kov, G.B.

    1976-01-01

    The modernized pulse electrostatic accelerator using the klystron ion grouping and the beam interruption system prior to acceleration is described. The accelerator is modernized in order to improve parameters of a current pulse and to decrease the background in the measurement room. The ion beam of needed dimensions is obtained with the help of a high-frequency source and a beam grouping and deflection system. The general view of the beam grouping and deflection system is shown. The ion beam forming process is considered in detail. The modernized electrostatic accelerator permits to obtain a pulse current with a pulse length of 1.5 ns and an amplitude of 1.5 - 2 μA. With the repetition frequency of 2 MHz, the average target current is about 6 μA

  19. The Spiritual Well-Being Scale: Psychometric Evaluation of the Shortened Version in Czech Adolescents.

    Malinakova, Klara; Kopcakova, Jaroslava; Kolarcik, Peter; Geckova, Andrea Madarasova; Solcova, Iva Polackova; Husek, Vit; Kracmarova, Lucie Kluzova; Dubovska, Eva; Kalman, Michal; Puzova, Zuzana; van Dijk, Jitse P; Tavel, Peter

    2017-04-01

    The aim of this study was to psychometrically evaluate the shortened version of the Spiritual Well-Being Scale (SWBS) in Czech adolescents. A nationally representative sample of 4217 adolescents participated in the 2014 Health Behaviour in School-aged Children survey. The internal consistency of the SWBS was assessed using Cronbach's alpha (α) and Mean Inter-Item Correlation (MIIC) values. The factor structure was evaluated using principal component analyses. After adjustment, our new seven-item version of the scale supports a two-factorial model of the SWBS with satisfactory internal consistency (α = 0.814, MIIC = 0.379). This version of the SWBS is suitable for measuring spiritual well-being in a secularising environment.

  20. Radiation-induced life shortening in neonatally thymectomized germ-free mice

    Anderson, R.E.; Howarth, J.L.; Troup, G.M.

    1980-01-01

    Radiation in sufficient amounts is carcinogenic, immunosuppressive, and results in a reduced life span. Similar consequences follow neonatal thymectomy (nTx) in some strains of rodents. The tumorigenic effects of irradiation appear to be partly mediated via suppression of the thymus-dependent portion of the immune response. Our purpose was to determine whether a similar relationship exists for radiation-induced accelerated aging. Female germ-free Charles River mice had neonatal or sham thymectomies within 24 hours of birth. Half of each group was exposed to 700 rads at 6 weeks of age. When mice with histologically malignant tumors were excluded, the combined life-shortening effects of nTx and irradiation were less pronounced than the sum of the individual effects. This suggests that some of the decreased longevity associated with irradiation may be mediated by T-cell injury

  1. Effect of hindlimb unweighting on single soleus fiber maximal shortening velocity and ATPase activity

    Mcdonald, K. S.; Fitts, R. H.

    1993-01-01

    The effect of hindlimb unweighting (HU) for 1 to 3 wks on the shortening velocity of a soleus fiber, its ATPase content, and the relative contents of the slow and fast myosin was investigated by measuring fiber force, V(0), ATPase activity, and myosin content in SDS protein profiles of a single rat soleus fiber suspended between a motor arm and a transducer. It was found that HU induces a progressive increase in fiber V(0) that is likely caused, at least in part, by an increase in the fiber's myofibrillar ATPase activity. The HU-induced increases in V(0) and ATPase were associated with the presence of a greater percentage of fast type IIa fibers. However, a large population of fibers after 1, 2, and 3 wks of HU showed increases in V(0) and ATPase but displayed the same myosin protein profile on SDS gels as control fibers.

  2. Spontaneous delayed migration/shortening of the pipeline embolization device: report of 5 cases.

    Chalouhi, N; Tjoumakaris, S I; Gonzalez, L F; Hasan, D; Pema, P J; Gould, G; Rosenwasser, R H; Jabbour, P M

    2013-12-01

    Five patients were found to have spontaneous delayed migration/shortening of their Pipeline Embolization Devices on follow-up angiography. The device migrated proximally in 4 patients and distally in 1 patient. One patient had a subarachnoid hemorrhage and died as a result of migration of the Pipeline Embolization Device, and another patient presented with complete MCA occlusion and was left severely disabled. Mismatch in arterial diameter between inflow and outflow vessels was a constant finding. Migration of the Pipeline Embolization Device was managed conservatively, with additional placement of the device, or with parent vessel occlusion. Obtaining complete expansion of the embolization device by using a longer device, increasing vessel coverage, using adjunctive aneurysm coiling, and avoiding dragging and stretching of the device are important preventive measures. Neurointerventionalists should be aware of this potentially fatal complication and take all necessary preventive measures.

  3. Shortened constraint-induced movement therapy in subacute stroke - no effect of using a restraint

    Brogårdh, Christina; Vestling, Monika; Sjölund, Bengt H

    2009-01-01

    OBJECTIVE: To examine the effect of using a mitt during shortened constraint-induced movement therapy for patients in the subacute phase after stroke. SUBJECTS: Twenty-four patients with stroke (mean age 57.6 (standard deviation (SD) 8.5) years; average 7 weeks post-stroke) with mild to moderate......, no statistically significant differences between the groups were found in any measures at any point in time. CONCLUSION: In this study, no effect of using a restraint in patients with subacute stroke was found. Thus, this component in the constraint-induced therapy concept seems to be of minor importance...... Scale, the Sollerman hand function test, the 2-Point Discrimination test and Motor Activity Log test. RESULTS: Patients in both groups showed significant improvements in arm and hand motor performance and on self-reported motor ability after 2 weeks of therapy and at 3 months follow-up. However...

  4. International Year of Pulses 2016 | 2016 International Year of Pulses

    the Year in collaboration with Governments, relevant organizations, non-governmental organizations and the composition of pulses Image 4 Wrapping up the International Year of Pulses The 5 key messages to food security Infographic Pulses and climate change International Year of Pulses 2016 The 68th UN

  5. Realtime aspects of pulse-to-pulse modulation

    Steiner, R.; Riedel, C.; Roesch, W.

    1992-01-01

    The pulse-to-pulse modulation of the SIS-ESR control system is described. Fast response to operator interaction and to changes in process conditions is emphasized as well as the essential part played by the timing system in pulse-to-pulse modulation. (author)

  6. Pulsed spallation Neutron Sources

    Carpenter, J.M.

    1994-01-01

    This paper reviews the early history of pulsed spallation neutron source development at Argonne and provides an overview of existing sources world wide. A number of proposals for machines more powerful than currently exist are under development, which are briefly described. The author reviews the status of the Intense Pulsed Neutron Source, its instrumentation, and its user program, and provides a few examples of applications in fundamental condensed matter physics, materials science and technology

  7. Pulsed spallation neutron sources

    Carpenter, J.M.

    1996-01-01

    This paper reviews the early history of pulsed spallation neutron source development ar Argonne and provides an overview of existing sources world wide. A number of proposals for machines more powerful than currently exist are under development, which are briefly described. The author reviews the status of the Intense Pulsed Neutron Source, its instrumentation, and its user program, and provide a few examples of applications in fundamental condensed matter physics, materials science and technology

  8. Intravenous glutamine does not modify leucocyte count but shortens duration of mucositis after bone marrow transplant

    María Belén Andrade Hernández

    2018-04-01

    Full Text Available Rationale: Intravenous administration of Glutamine dipeptides (Gln has been proposed as treatment of oral mucositis following a bone marrow transplant (BMT. Objective: To establish the effects of intravenous Gln supplementation upon the severity of oral mucositis after BMT. Study design: Retrospective, analytical. Study serie: Records from 25 patients (Males: 56.0%; BMT cause: Leukemia: 64.0% who developed oral mucositis (Grades III – IV: 48.0% after BMT (Autologous: 44.0% at the "Juan Tanca Marengo" Hospital (Guayaquil, Ecuador between 2009 – 2017. Glutamine source: Dipeptiven©®: 13 grams of Gln suspended in 100 milliliters of a 20% solution of the alanine-glutamine dipeptide (Fresenius-Kabi©®, Germany. Materials and Methods: Gln-treated patients received 3(4.0% of the treatment leg, 5 (20.0%; 6 (12.0%; 7 (48.0%; or 10 (16.0% doses of the dipeptide until resolution of the symptoms. Impact of Gln was estimated from changes observed in the severity and duration of mucositis, white blood cell counts, and body weight regarding 25 non-Gln treated patients (Males: 68.0%; Leukemias: 32.0%; Autologous graft: 68.0%; Grade III – IV mucositis: 48.0%. Results: Intravenously-administered Gln shortened duration of oral mucositis: Gln-Treated: 12.5 ± 5.1 days vs. Non-Gln Treated: 21.3 ± 17.8 days (p < 0.05. Also, intravenous Gln marginally ameliorated loss of body weight: Gln-Treated -4.5 ± 5.5% vs. Non-Gln Treated: -7.5 ± 5.7% (p = 0.07. Conclusions: Intravenous Gln administration shortens duration of oral mucositis following BMT. Gln effect might be translated to a lesser weight loss in patients with oral mucositis.

  9. Analysis of combination drug therapy to develop regimens with shortened duration of treatment for tuberculosis.

    George L Drusano

    Full Text Available Tuberculosis remains a worldwide problem, particularly with the advent of multi-drug resistance. Shortening therapy duration for Mycobacterium tuberculosis is a major goal, requiring generation of optimal kill rate and resistance-suppression. Combination therapy is required to attain the goal of shorter therapy.Our objective was to identify a method for identifying optimal combination chemotherapy. We developed a mathematical model for attaining this end. This is accomplished by identifying drug effect interaction (synergy, additivity, antagonism for susceptible organisms and subpopulations resistant to each drug in the combination.We studied the combination of linezolid plus rifampin in our hollow fiber infection model. We generated a fully parametric drug effect interaction mathematical model. The results were subjected to Monte Carlo simulation to extend the findings to a population of patients by accounting for between-patient variability in drug pharmacokinetics.All monotherapy allowed emergence of resistance over the first two weeks of the experiment. In combination, the interaction was additive for each population (susceptible and resistant. For a 600 mg/600 mg daily regimen of linezolid plus rifampin, we demonstrated that >50% of simulated subjects had eradicated the susceptible population by day 27 with the remaining organisms resistant to one or the other drug. Only 4% of patients had complete organism eradication by experiment end.These data strongly suggest that in order to achieve the goal of shortening therapy, the original regimen may need to be changed at one month to a regimen of two completely new agents with resistance mechanisms independent of the initial regimen. This hypothesis which arose from the analysis is immediately testable in a clinical trial.

  10. Anesthetic Sevoflurane Causes Rho-Dependent Filopodial Shortening in Mouse Neurons.

    Jeffrey H Zimering

    Full Text Available Early postnatal anesthesia causes long-lasting learning and memory impairment in rodents, however, evidence for a specific neurotoxic effect on early synaptogenesis has not been demonstrated. Drebrin A is an actin binding protein whose localization in dendritic protrusions serves an important role in dendritic spine morphogenesis, and is a marker for early synaptogenesis. We therefore set out to investigate whether clinically-relevant concentrations of anesthetic sevoflurane, widely- used in infants and children, alters dendritic morphology in cultured fetal day 16 mouse hippocampal neurons. After 7 days in vitro, mouse hippocampal neurons were exposed to four hours of 3% sevoflurane in 95% air/5% CO2 or control condition (95% air/5% CO2. Neurons were fixed in 4% paraformaldehyde and stained with Alexa Fluor555-Phalloidin, and/or rabbit anti-mouse drebrin A/E antibodies which permitted subcellular localization of filamentous (F-actin and/or drebrin immunoreactivity, respectively. Sevoflurane caused acute significant length-shortening in filopodia and thin dendritic spines in days-in-vitro 7 neurons, an effect which was completely rescued by co-incubating neurons with ten micromolar concentrations of the selective Rho kinase inhibitor Y27632. Filopodia and thin spine recovered in length two days after sevoflurane exposure. Yet cluster-type filopodia (a precursor to synaptic filopodia were persistently significantly decreased in number on day-in-vitro 9, in part owing to preferential localization of drebrin immunoreactivity to dendritic shafts versus filopodial stalks. These data suggest that sevoflurane induces F-actin depolymerization leading to acute, reversible length-shortening in dendritic protrusions through a mechanism involving (in part activation of RhoA/Rho kinase signaling and impairs localization of drebrin A to filopodia required for early excitatory synapse formation.

  11. A structural and kinetic study on myofibrils prevented from shortening by chemical cross-linking.

    Herrmann, C; Sleep, J; Chaussepied, P; Travers, F; Barman, T

    1993-07-20

    In previous work, we studied the early steps of the Mg(2+)-ATPase activity of Ca(2+)-activated myofibrils [Houadjeto, M., Travers, F., & Barman, T. (1992) Biochemistry 31, 1564-1569]. The myofibrils were free to contract, and the results obtained refer to the ATPase cycle of myofibrils contracting with no external load. Here we studied the ATPase of myofibrils contracting isometrically. To prevent shortening, we cross-linked them with 1-ethyl-3-[3-(dimethylamino)propyl]carbodiimide (EDC). SDS-PAGE and Western blot analyses showed that the myosin rods were extensively cross-linked and that 8% of the myosin heads were cross-linked to the thin filament. The transient kinetics of the cross-linked myofibrils were studied in 0.1 M potassium acetate, pH 7.4 and 4 degrees C, by the rapid-flow quench method. The ATP binding steps were studied by the cold ATP chase and the cleavage and release of products steps by the Pi burst method. In Pi burst experiments, the sizes of the bursts were equal within experimental error to the ATPase site concentrations (as determined by the cold ATP chase methods) for both cross-linked (isometric) and un-cross-linked (isotonic) myofibrils. This shows that in both cases the rate-limiting step is after the cleavage of ATP. When cross-linked, the kcat of Ca(2+)-activated myofibrils was reduced from 1.7 to 0.8 s-1. This is consistent with the observation that fibers shortening at moderate velocity have a higher ATPase activity than isometric fibers.(ABSTRACT TRUNCATED AT 250 WORDS)

  12. Unloaded shortening velocity of voluntarily and electrically activated human dorsiflexor muscles in vivo.

    Kazushige Sasaki

    Full Text Available We have previously shown that unloaded shortening velocity (V(0 of human plantar flexors can be determined in vivo, by applying the "slack test" to submaximal voluntary contractions (J Physiol 567:1047-1056, 2005. In the present study, to investigate the effect of motor unit recruitment pattern on V(0 of human muscle, we modified the slack test and applied this method to both voluntary and electrically elicited contractions of dorsiflexors. A series of quick releases (i.e., rapid ankle joint rotation driven by an electrical dynamometer was applied to voluntarily activated dorsiflexor muscles at three different contraction intensities (15, 50, and 85% of maximal voluntary contraction; MVC. The quick-release trials were also performed on electrically activated dorsiflexor muscles, in which three stimulus conditions were used: submaximal (equal to 15%MVC 50-Hz stimulation, supramaximal 50-Hz stimulation, and supramaximal 20-Hz stimulation. Modification of the slack test in vivo resulted in good reproducibility of V(0, with an intraclass correlation coefficient of 0.87 (95% confidence interval: 0.68-0.95. Regression analysis showed that V(0 of voluntarily activated dorsiflexor muscles significantly increased with increasing contraction intensity (R(2 = 0.52, P<0.001. By contrast, V(0 of electrically activated dorsiflexor muscles remained unchanged (R(2<0.001, P = 0.98 among three different stimulus conditions showing a large variation of tetanic torque. These results suggest that the recruitment pattern of motor units, which is quite different between voluntary and electrically elicited contractions, plays an important role in determining shortening velocity of human skeletal muscle in vivo.

  13. Measurements of weak conversion lines

    Feoktistov, A.I.; Frantsev, Yu.E.

    1979-01-01

    Described is a new methods for measuring weak conversion lines with the help of the β spectrometer of the π √ 2 type which permits to increase the reliability of the results obtained. According to this method the measurements were carried out by short series with the storage of the information obtained on the punched tape. The spectrometer magnetic field was stabilized during the measuring of the conversion spectra with the help of three nmr recorders. Instead of the dependence of the pulse calculation rate on the magnetic field value was measured the dependence of the calculation rate on the value of the voltage applied between the source and the spectrometer chamber. A short description of the automatic set-up for measuring conversion lines according to the method proposed is given. The main set-up elements are the voltage multiplexer timer, printer, scaler and the pulse analyzer. With the help of the above methods obtained is the K 1035, 8 keV 182 Ta line. It is obtained as a result of the composition of 96 measurement series. Each measurement time constitutes 640 s 12 points are taken on the line

  14. The nanosecond generator RG-1 with near-rectangular pulse

    Bulan, V.V.; Grabovskij, E.V.; Gribov, A.N.; Luzhnov, V.G.

    1996-01-01

    The 300 kV, 17 Ohm generator RG-1, which can deliver near-rectangular pulses with a pulse duration of 80 ns FWHM, is described. The polarity of the output pulse can be changed by a simple switch. The fast capacities of the Marx generator are used instead of the pulse forming line. Multi-spark gas switches were developed to decrease the inductance of the discharged circuit. The generator is supplied by a built-in high voltage source and its operation is controlled by a minicomputer. It is used the power supply-line 220 V. The RG-1 can be used in different modes of operation: gas discharge, particle beam formation, etc. (author). 4 figs., 3 refs

  15. The nanosecond generator RG-1 with near-rectangular pulse

    Bulan, V V; Grabovskij, E V; Gribov, A N; Luzhnov, V G [TRINITI, Troitsk (Russian Federation)

    1997-12-31

    The 300 kV, 17 Ohm generator RG-1, which can deliver near-rectangular pulses with a pulse duration of 80 ns FWHM, is described. The polarity of the output pulse can be changed by a simple switch. The fast capacities of the Marx generator are used instead of the pulse forming line. Multi-spark gas switches were developed to decrease the inductance of the discharged circuit. The generator is supplied by a built-in high voltage source and its operation is controlled by a minicomputer. It is used the power supply-line 220 V. The RG-1 can be used in different modes of operation: gas discharge, particle beam formation, etc. (author). 4 figs., 3 refs.

  16. A Comparative Field Monitoring of Column Shortenings in Tall Buildings Using Wireless and Wired Sensor Network Systems

    Sungho Lee

    2016-01-01

    Full Text Available A comparative field measurement for column shortening of tall buildings is presented in this study, with a focus on the reliability and stability of a wireless sensor network. A wireless sensor network was used for monitoring the column shortenings of a 58-story building under construction. The wireless sensor network, which was composed of sensor and master nodes, employed the ultra-high-frequency band and CDMA communication methods. To evaluate the reliability and stability of the wireless sensor network system, the column shortenings were also measured using a conventional wired monitoring system. Two vibration wire gauges were installed in each of the selected 7 columns and 3 walls. Measurements for selected columns and walls were collected for 270 days after casting of the concrete. The results measured by the wireless sensor network were compared with the results of the conventional method. The strains and column shortenings measured using both methods showed good agreement for all members. It was verified that the column shortenings of tall buildings could be monitored using the wireless sensor network system with its reliability and stability.

  17. Broadband and short (10-ps) pulse generation on Nova

    Perry, M.D.; Browning, D.; Bibeau, C.; Patterson, F.G.; Wilcox, R.; Henesian, M.

    1990-01-01

    The ability to produce high power broadband pulses for purposes of focal spot beam smoothing has recently become an important issue in inertial confinement fusion (ICF). As the first step toward the generation and propagation of such pulses on Nova, the authors have performed a series of experiments with 10-ps pulses. Aside from the inherently broad bandwidth, these short pulses have important applications in ICF experiments and x-ray laser research. The author's experimental results are discussed. The short pulses were produced by diffraction grating pulse compression of chirped pulses formed from self-phase modulation in a single-mode 10-m fused silica fiber. Use of such a short fiber produces a nonlinearly chirped spectrum of 0.74 nm. The central nearly linearly chirped 0.26 nm is selected by polarization discrimination and compressed using 1800-line/mm diffraction gratings to a nearly Gaussian pulse of 10 ps FWHM with an energy contrast ratio of 20:1. This 1-nJ pulse is injected into a Nova amplifier chain with selected amplifiers unfired

  18. Pulse Wave Variation during the Menstrual Cycle in Women with Menstrual Pain

    Soo Hyung Jeon

    2016-01-01

    Full Text Available Objective. This study is performed to obtain objective diagnostic indicators associated with menstrual pain using pulse wave analysis. Methods. Using a pulse diagnostic device, we measured the pulse waves of 541 women aged between 19 and 30 years, placed in either an experimental group with menstrual pain (n=329 or a control group with little or no menstrual pain (n=212. Measurements were taken during both the menstrual and nonmenstrual periods, and comparative analysis was performed. Results. During the nonmenstrual period, the experimental group showed a significantly higher value in the left radial artery for the radial augmentation index (RAI (p=0.050 but significantly lower values for pulse wave energy (p=0.021 and time to first peak from baseline (T1 (p=0.035 in the right radial artery. During the menstrual period, the experimental group showed significantly lower values in the left radial artery for cardiac diastole and pulse wave area during diastole and significantly higher values for pulse wave area during systole, ratio of systolic phase to the full heartbeat, and systolic-diastolic ratio. Conclusion. We obtained indicators of menstrual pain in women during the menstrual period, including prolonged systolic and shortened diastolic phases, increases in pulse wave energy and area of representative pulse wave, and increased blood vessel resistance.

  19. Pulsed corona generation using a diode-based pulsed power generator

    Pemen, A. J. M.; Grekhov, I. V.; van Heesch, E. J. M.; Yan, K.; Nair, S. A.; Korotkov, S. V.

    2003-10-01

    Pulsed plasma techniques serve a wide range of unconventional processes, such as gas and water processing, hydrogen production, and nanotechnology. Extending research on promising applications, such as pulsed corona processing, depends to a great extent on the availability of reliable, efficient and repetitive high-voltage pulsed power technology. Heavy-duty opening switches are the most critical components in high-voltage pulsed power systems with inductive energy storage. At the Ioffe Institute, an unconventional switching mechanism has been found, based on the fast recovery process in a diode. This article discusses the application of such a "drift-step-recovery-diode" for pulsed corona plasma generation. The principle of the diode-based nanosecond high-voltage generator will be discussed. The generator will be coupled to a corona reactor via a transmission-line transformer. The advantages of this concept, such as easy voltage transformation, load matching, switch protection and easy coupling with a dc bias voltage, will be discussed. The developed circuit is tested at both a resistive load and various corona reactors. Methods to optimize the energy transfer to a corona reactor have been evaluated. The impedance matching between the pulse generator and corona reactor can be significantly improved by using a dc bias voltage. At good matching, the corona energy increases and less energy reflects back to the generator. Matching can also be slightly improved by increasing the temperature in the corona reactor. More effective is to reduce the reactor pressure.

  20. Software emulator of nuclear pulse generation with different pulse shapes and pile-up

    Pechousek, Jiri, E-mail: jiri.pechousek@upol.cz [Department of Experimental Physics, Faculty of Science, Palacky University, 17. listopadu 1192/12, 771 46 Olomouc (Czech Republic); Konecny, Daniel [Department of Optics, Faculty of Science, Palacky University, 17. listopadu 1192/12, 77 146 Olomouc (Czech Republic); Novak, Petr; Kouril, Lukas; Kohout, Pavel [Department of Experimental Physics, Faculty of Science, Palacky University, 17. listopadu 1192/12, 771 46 Olomouc (Czech Republic); Celiktas, Cuneyt [Department of Physics, Faculty of Science, Ege University, Bornova, Izmir (Turkey); Vujtek, Milan [Department of Experimental Physics, Faculty of Science, Palacky University, 17. listopadu 1192/12, 771 46 Olomouc (Czech Republic)

    2016-08-21

    The optimal detection of output signals from nuclear counting devices represents one of the key physical factors that govern accuracy and experimental reproducibility. In this context, the fine calibration of the detector under diverse experimental scenarios, although time costly, is necessary. However this process can be rendered easier with the use of systems that work in lieu of emulators. In this report we describe an innovative programmable pulse generator device capable to emulate the scintillation detector signals, in a way to mimic the detector performances under a variety of experimental conditions. The emulator generates a defined number of pulses, with a given shape and amplitude in the form of a sampled detector signal. The emulator output is then used off-line by a spectrometric system in order to set up its optimal performance. Three types of pulse shapes are produced by our device, with the possibility to add noise and pulse pile-up effects into the signal. The efficiency of the pulse detection, pile-up rejection and/or correction, together with the dead-time of the system, are therein analyzed through the use of some specific algorithms for pulse processing, and the results obtained validate the beneficial use of emulators for the accurate calibration process of spectrometric systems.

  1. Particle acceleration by electromagnetic pulses

    Lai, H.M.

    1982-01-01

    Particle interaction with plane electromagnetic pulses is studied. It is shown that particle acceleration by a wavy pulse, depending on the shape of the pulse, may not be small. Further, a diffusive-type particle acceleration by multiple weak pulses is described and discussed. (author)

  2. Absorption of Ultrashort Electromagnetic Pulses on Broadened Dipole Transitions

    Svita, S Yu; Astapenko, V A

    2014-01-01

    The study is devoted to the theoretical analysis of ultrashort electromagnetic pulses (USP) absorption on broadened dipole transitions. Calculations are made in the frame of perturbation theory with the use of the basic formula for energy absorbed during all time of the action of USP on dipole transition. Dependences of absorbed energy upon pulse duration and carrier frequency are obtained and analyzed for different types of spectral line shape and USP parameters

  3. Development of the pulsed muon facility at ISIS

    Eaton, G.H.; Scott, C.A.; Williams, W.G.

    1994-01-01

    The ISIS pulsed surface muon facility at RAL is presently undergoing a major expansion to provide three experimental ports with simultaneous single muon pulses at 50 Hz. This upgrade, funded by the European Community (EC), is described together with recent development results which are relevant to its future scientific programme. These new beam lines are expected to be available for experiments in June 1993. (orig.)

  4. Dynamics of traveling reaction pulses

    Dovzhenko, A. Yu.; Rumanov, E. N.

    2007-01-01

    The growth of activator losses is accompanied by the decay of a traveling reaction pulse. In a ring reactor, this propagation threshold is present simultaneously with a threshold related to the ring diameter. The results of numerical experiments with pulses of an exothermal reaction reveal the transition from pulse propagation to a homogeneous hot regime, established regimes with periodic variations of the pulse velocity, and oscillatory decay of the pulse. When the medium becomes 'bistable' as a result of the variation in parameters, this factor does not prevent the propagation of pulses, but leads to changes in the pulse structure

  5. A 70 MHz pulsing beam system for protons

    An Shizhong; Zhang Tianjue; Wu Longcheng; Lv Yinlong; Song Guofang; Guan Fengping; Jia Xianlu

    2008-01-01

    A test beam line for pulsed beam generation for 10 MeV central region model (CRM) of a compact cyclotron is under construction as China Institute of Atomic Energy (CIAE). A 70 MHz continuous H - beam with the energy of dozens of keV or a hundred keV will be pulsed to pulse length of less than 10 ns with the repetition rate of 1-8 MHz. A 70.487 MHz buncher will be used to compress the DC beam into the RF phase acceptance of ±30° of the CRM cyclotron. The 2.2 MHz sine waveform will be used for the chopper. A pulse with the repetition rate to 4.4 MHz and pulse length less than 10 ns is expected after CRM cyclotron. (authors)

  6. Study of general digital DC/pulse neutron generator

    Li Gang; Liu Zheng; Li Wensheng; Liu Hanlin; Liu Linmao

    2014-01-01

    Preliminary experimental results of digital DC/pulse neutron generator based on a ceramic drive-in target neutron tube for explosives detection are presented. The generator is a portable and on-off neutron source, and it can be controlled by remote PC. The generator can produce DC neutrons, pulse neutrons and multiple pulse neutrons. The maximum neutron yield is about 2 × 10"8 n/s, the minimum pulse width is 10 μs and the maximum pulse frequency is 10 kHz. Neutron yield and time-spectrum is measured in China Academy of Engineering Physics. The generator is suitable for explosive detection with PFTNA technology, and it can be used in other areas such as reactor measurements and on-line industrial test systems. (authors)

  7. Ionization and pulse lethargy effects in inverse Cherenkov accelerators

    Sprangle, P.; Hubbard, R.F.; Hafizi, B.

    1997-01-01

    Ionization processes limit the accelerating gradient and place an upper limit on the pulse duration of the electromagnetic driver in the inverse Cherenkov accelerator (ICA). Group velocity slippage, i.e., pulse lethargy, on the other hand, imposes a lower limit on the pulse duration. These limits are obtained for two ICA configurations in which the electromagnetic driver (e.g., laser or millimeter wave source) is propagated in a waveguide that is (i) lined with a dielectric material or (ii) filled with a neutral gas. In either configuration the electromagnetic driving field is guided and has an axial electric field with phase velocity equal to the speed of light in vacuum, c. The intensity of the driver in the ICA, and therefore the acceleration gradient, is limited by tunneling and collisional ionization effects. Partial ionization of the dielectric liner or gas can lead to significant modification of the dispersive properties of the waveguide, altering the phase velocity of the accelerating field and causing particle slippage, thus disrupting the acceleration process. An additional limitation on the pulse duration is imposed since the group velocity of the driving pulse is less than c and the pulse slips behind the accelerated electrons. Hence for sufficiently short pulses the electrons outrun the pulse, terminating the acceleration. Limitations on the driver pulse duration and accelerating gradient, due to ionization and pulse lethargy, are estimated for the two ICA configurations. Maximum accelerating gradients and pulse durations are presented for a 10 μm, 1 mm, and 1 cm wavelength electromagnetic driver. The combination of ionization and pulse lethargy effects impose severe limitations on the maximum energy gain in inverse Cherenkov accelerators. copyright 1997 The American Physical Society

  8. Induction effect of an electromagnetic pulse on transmission line

    Pazirandeh, A.; Maleki, P.; Sardari, D.

    2004-01-01

    Ever increasing demand for and vital importance of communication systems and power transmission to our industries, transportation to work, hospitals, and many other important places deemed necessary to have safety based design considerations. Many natural phenomena and man-made devices may generate powerful and intensive EMP, which is very harmful to the safe mode operation of electrical and communicational systems. In this paper we have calculated induced electric field and power induction due to lightening, nuclear explosion and similar events to the aerial and underground cables

  9. SCREAMER: a single-line pulsed-power design tool

    Kiefer, M.L.; Widner, M.M.

    1985-01-01

    SCREAMER is a special purpose circuit code developed as a design tool for single module accelerators. It is fast, accurate, flexible, and user-friendly. Its development was motivated by the excessive costs and long turn-around times incurred when using the SCEPTRE circuit analysis code to perform simulations of circuits with large numbers of nodes and with nonlinear components. Comparable simulations between SCREAMER running on a VAX 11/780 and SCEPTRE running on a CRAY-1S show that turn-around times and costs can be two orders of magnitude lower when using SCREAMER

  10. SCREAMER - A single-line pulsed-power design tool

    Kiefer, M.L.; Widner, M.M.

    1985-01-01

    SCREAMER is a special purpose circuit code developed as a design tool for single module accelerators. it is fast, accurate, flexible, and user-friendly. Its development was motivated by the excessive costs and long turn-around times incurred when using the SCEPTRE circuit analysis code to perform simulations of circuits with large numbers of modes and with nonlinear components. Comparable simulations between SCREAMER running on a VAX 11/780 and SCEPTRE running on a CRAY-1S show that turn-around times and costs can be two orders of magnitude lower when using SCREAMER

  11. production lines

    Jingshan Li

    2000-01-01

    Full Text Available In this work, serial production lines with finished goods buffers operating in the pull regime are considered. The machines are assumed to obey Bernoulli reliability model. The problem of satisfying customers demand is addressed. The level of demand satisfaction is quantified by the due-time performance (DTP, which is defined as the probability to ship to the customer a required number of parts during a fixed time interval. Within this scenario, the definitions of DTP bottlenecks are introduced and a method for their identification is developed.

  12. Clinical efficacy comparison of flabby skin excision combined orbicularis oculi muscle shortening surgery in patients with senile entropion

    Qing-Liang Xu

    2015-07-01

    Full Text Available AIM: To observe the clinical effect of slack skin excision combined with orbicularis oculi muscle shortening and orbicularis muscle shortening in the treatment of elderly patients with lower eyelid entropion, and provide the reference for the clinical treatment.METHODS: Eighty-two(126 eyesclinical diagnosis's elderly patients with lower eyelid entropion were collected from our department, then randomly divided into excised relaxing skin and orbicularis oculi muscle shortening treatment group and the orbicularis muscle shortening treatment group.The general data of the two groups, long term curative effect and short-term curative effect were compared. RESULTS: The age, sex, proportion of patients with the first time operation, course of disease were no statistical significance between the observation group and the control group(P>0.05. The short-term effective rate of the observation group was 95.2%, while the short-term effective rate of the control group was 77.8%, the short-term efficiency differences between the two groups was statistical significance(χ2=4.100, P=0.043. The long-term cure rate of the observation group was 82.5%(34 cases, 52 eyes, recurrence rate was 17.5%(7 cases, 11 eyes, while the cure rate of the control group was 60.3%(25 cases, 38 eyes, recurrence rate was 39.7%(16 cases, 25 eyes, the difference of long term cure rate was statistical significance between the two groups(PCONCLUSION: The clinical curative effect of slack skin excision combined with orbicularis oculi muscle shortening in the treatment of senile inferior entropion is better than orbicularis muscle shortening operation, recommending application in the clinical.

  13. Supermassive Black Holes with High Accretion Rates in Active Galactic Nuclei. IX. 10 New Observations of Reverberation Mapping and Shortened Hβ Lags

    Du, Pu; Zhang, Zhi-Xiang; Wang, Kai; Huang, Ying-Ke; Zhang, Yue; Lu, Kai-Xing; Hu, Chen; Li, Yan-Rong; Bai, Jin-Ming; Bian, Wei-Hao; Yuan, Ye-Fei; Ho, Luis C.; Wang, Jian-Min; SEAMBH collaboration

    2018-03-01

    As one paper in a series reporting on a large reverberation mapping campaign of super-Eddington accreting massive black holes (SEAMBHs) in active galactic nuclei (AGNs), we present the results of 10 SEAMBHs monitored spectroscopically during 2015–2017. Six of them are observed for the first time, and have generally higher 5100 Å luminosities than the SEAMBHs monitored in our campaign from 2012 to 2015; the remaining four are repeat observations to check if their previous lags change. Similar to the previous SEAMBHs, the Hβ time lags of the newly observed objects are shorter than the values predicted by the canonical R Hβ –L 5100 relation of sub-Eddington AGNs, by factors of ∼2–6, depending on the accretion rate. The four previously observed objects have lags consistent with previous measurements. We provide linear regressions for the R Hβ –L 5100 relation, solely for the SEAMBH sample and for low-accretion AGNs. We find that the relative strength of Fe II and the profile of the Hβ emission line can be used as proxies of accretion rate, showing that the shortening of Hβ lags depends on accretion rates. The recent SDSS-RM discovery of shortened Hβ lags in AGNs with low accretion rates provides compelling evidence for retrograde accretion onto the black hole. These evidences show that the canonical R Hβ –L 5100 relation holds only in AGNs with moderate accretion rates. At low accretion rates, it should be revised to include the effects of black hole spin, whereas the accretion rate itself becomes a key factor in the regime of high accretion rates.

  14. Line facilities outline

    1998-08-01

    This book deals with line facilities. The contents of this book are outline line of wire telecommunication ; development of line, classification of section of line and theory of transmission of line, cable line ; structure of line, line of cable in town, line out of town, domestic cable and other lines, Optical communication ; line of optical cable, transmission method, measurement of optical communication and cable of the sea bottom, Equipment of telecommunication line ; telecommunication line facilities and telecommunication of public works, construction of cable line and maintenance and Regulation of line equipment ; regulation on technique, construction and maintenance.

  15. Effects of rapid shortening on rate of force regeneration and myoplasmic [Ca2+] in intact frog skeletal muscle fibres

    Vandenboom, R; Claflin, D R; Julian, F J

    1998-01-01

    The effect of rapid shortening on rate of force regeneration (dF/dtR) was examined in single, intact frog (Rana temporaria) skeletal muscle fibres (3·0 °C). Step releases leading to unloaded shortening were applied after 500 ms of stimulation, during the plateau of an isometric tetanus. Initial mean sarcomere length ranged from 2·05 to 2·35 μm; force regeneration after shortening was at 2·00 μm.Values for dF/dtR following a 25 nm half-sarcomere−1 release were 3·17 ± 0·17 (mean ± s.e.m., n= 8) times greater than the initial rate of rise of force before release (dF/dtI). As release size was increased from 25 to 175 nm half-sarcomere−1, the relationship between release size and dF/dtR decreased sharply before attaining a plateau value that was 1·34 ± 0·09 times greater than dF/dtI. Despite wide variations in dF/dtR, the velocity of unloaded shortening remained constant (2·92 ± 0·08 μm half-sarcomere−1 s−1; n= 8) for the different release amplitudes used in this study.To investigate its role in the attenuation of dF/dtR with increased shortening, the effects of rapid ramp (constant velocity) shortening on intracellular free Ca2+ concentration ([Ca2+]i) were monitored using the Ca2+-sensitive fluorescent dye furaptra. Compared with an isometric contraction, rapid fibre shortening was associated with a transient increase in [Ca2+]i while force regeneration after shortening was associated with a transient reduction in [Ca2+]i. The greatest reductions in [Ca2+]i were associated with the largest amplitude ramps.Cross-bridge-mediated modifications of the Ca2+ affinity of troponin C (TnC) may explain the fluctuations in [Ca2+]i observed during and after ramps. Associated fluctuations in TnC Ca2+ occupancy could play a role in the reduction of dF/dtR with increasing release size. PMID:9679172

  16. 3D T2-weighted imaging to shorten multiparametric prostate MRI protocols.

    Polanec, Stephan H; Lazar, Mathias; Wengert, Georg J; Bickel, Hubert; Spick, Claudio; Susani, Martin; Shariat, Shahrokh; Clauser, Paola; Baltzer, Pascal A T

    2018-04-01

    To determine whether 3D acquisitions provide equivalent image quality, lesion delineation quality and PI-RADS v2 performance compared to 2D acquisitions in T2-weighted imaging of the prostate at 3 T. This IRB-approved, prospective study included 150 consecutive patients (mean age 63.7 years, 35-84 years; mean PSA 7.2 ng/ml, 0.4-31.1 ng/ml). Two uroradiologists (R1, R2) independently rated image quality and lesion delineation quality using a five-point ordinal scale and assigned a PI-RADS score for 2D and 3D T2-weighted image data sets. Data were compared using visual grading characteristics (VGC) and receiver operating characteristics (ROC)/area under the curve (AUC) analysis. Image quality was similarly good to excellent for 2D T2w (mean score R1, 4.3 ± 0.81; R2, 4.7 ± 0.83) and 3D T2w (mean score R1, 4.3 ± 0.82; R2, 4.7 ± 0.69), p = 0.269. Lesion delineation was rated good to excellent for 2D (mean score R1, 4.16 ± 0.81; R2, 4.19 ± 0.92) and 3D T2w (R1, 4.19 ± 0.94; R2, 4.27 ± 0.94) without significant differences (p = 0.785). ROC analysis showed an equivalent performance for 2D (AUC 0.580-0.623) and 3D (AUC 0.576-0.629) T2w (p > 0.05, respectively). Three-dimensional acquisitions demonstrated equivalent image and lesion delineation quality, and PI-RADS v2 performance, compared to 2D in T2-weighted imaging of the prostate. Three-dimensional T2-weighted imaging could be used to considerably shorten prostate MRI protocols in clinical practice. • 3D shows equivalent image quality and lesion delineation compared to 2D T2w. • 3D T2w and 2D T2w image acquisition demonstrated comparable diagnostic performance. • Using a single 3D T2w acquisition may shorten the protocol by 40%. • Combined with short DCE, multiparametric protocols of 10 min are feasible.

  17. Injection-seeded tunable mid-infrared pulses generated by difference frequency mixing

    Miyamoto, Yuki; Hara, Hideaki; Masuda, Takahiko; Hiraki, Takahiro; Sasao, Noboru; Uetake, Satoshi

    2017-03-01

    We report on the generation of nanosecond mid-infrared pulses having frequency tunability, a narrow linewidth, and a high pulse energy. These pulses are obtained by frequency mixing between injection-seeded near-infrared pulses in potassium titanyl arsenate crystals. A continuous-wave external cavity laser diode or a Ti:sapphire ring laser is used as a tunable seeding source for the near-infrared pulses. The typical energy of the generated mid-infrared pulses is in the range of 0.4-1 mJ/pulse. The tuning wavelength ranges from 3142 to 4806 nm. A narrow linewidth of 1.4 GHz and good frequency reproducibility of the mid-infrared pulses are confirmed by observing a rovibrational absorption line of gaseous carbon monoxide at 4587 nm.

  18. Herophilus on pulse

    Afonasin, Eugene

    2015-01-01

    Full Text Available The first detailed study of the pulse (sphygmology is associated in antiquity with Herophilus (the end of the 4th century BCE, an Alexandrian physician, renowned for his anatomical discoveries. The scholars also attribute to him a discovery of a portable and adjustable water-clock, used for measuring ‘natural’ and ‘unnatural’ pulse and, accordingly, temperature of the patient. In the article we translate the principal ancient evidences and comment upon them. We study both the practical aspects of ancient sphygmology and the theoretical speculations associated with it. Ancient theory of proportion and musical harmony allowed to build a classification of the pulses, but the medical experience did not fit well in the Procrustean bed of this rather simple theory.

  19. Current Extensions on PULSE

    Sanda Dragos

    2010-09-01

    Full Text Available Using a learning management system (LMS is a common practise nowadays. Such instruments are used in educational institutions to enhance and support the teaching act as well as in industry for training purposes. In a computer science department of an university such instrument tends to be a basic requirement. That is because not only it allows a better management of courses and a better communication between students and professors, but can also serve as a perfect instrument for presenting teaching related materials for computer science subjects. During the years I have created and used several such instruments: a System with Interactive ackNowledgement and Evaluation of students work during laboratory sessions (SINE, a Php Utility used in Laboratories for Student Evaluation (PULSE, and PULSE Extended. The aim of this paper is to present the current enhancements of PULSE.

  20. Modeling digital pulse waveforms by solving one-dimensional Navier-stokes equations.

    Fedotov, Aleksandr A; Akulova, Anna S; Akulov, Sergey A

    2016-08-01

    Mathematical modeling for composition distal arterial pulse wave in the blood vessels of the upper limbs was considered. Formation of distal arterial pulse wave is represented as a composition of forward and reflected pulse waves propagating along the arterial vessels. The formal analogy between pulse waves propagation along the human arterial system and the propagation of electrical oscillations in electrical transmission lines with distributed parameters was proposed. Dependencies of pulse wave propagation along the human arterial system were obtained by solving the one-dimensional Navier-Stokes equations for a few special cases.

  1. Millimicrosecond pulse techniques

    Lewis, Ian A D

    1959-01-01

    Millimicrosecond Pulse Techniques, Second Edition focuses on millimicrosecond pulse techniques and the development of devices of large bandwidth, extending down to comparatively low frequencies (1 Mc/s). Emphasis is on basic circuit elements and pieces of equipment of universal application. Specific applications, mostly in the field of nuclear physics instrumentation, are considered. This book consists of eight chapters and opens with an introduction to some of the terminology employed by circuit engineers as well as theoretical concepts, including the laws of circuit analysis, Fourier analysi

  2. Pulsed Plasma Electron Sources

    Krasik, Yakov

    2008-11-01

    Pulsed (˜10-7 s) electron beams with high current density (>10^2 A/cm^2) are generated in diodes with electric field of E > 10^6 V/cm. The source of electrons in these diodes is explosive emission plasma, which limits pulse duration; in the case E Saveliev, J. Appl. Phys. 98, 093308 (2005). Ya. E. Krasik, A. Dunaevsky, and J. Felsteiner, Phys. Plasmas 8, 2466 (2001). D. Yarmolich, V. Vekselman, V. Tz. Gurovich, and Ya. E. Krasik, Phys. Rev. Lett. 100, 075004 (2008). J. Z. Gleizer, Y. Hadas and Ya. E. Krasik, Europhysics Lett. 82, 55001 (2008).

  3. Spallation neutrons pulsed sources

    Carpenter, J.

    1996-01-01

    This article describes the range of scientific applications which can use these pulsed neutrons sources: Studies on super fluids, measures to verify the crawling model for the polymers diffusion; these sources are also useful to study the neutron disintegration, the ultra cold neutrons. In certain applications which were not accessible by neutrons diffusion, for example, radiations damages, radionuclides production and activation analysis, the spallation sources find their use and their improvement will bring new possibilities. Among others contributions, one must notice the place at disposal of pulsed muons sources and neutrinos sources. (N.C.). 3 figs

  4. Pulse Doppler radar

    Alabaster, Clive

    2012-01-01

    This book is a practitioner's guide to all aspects of pulse Doppler radar. It concentrates on airborne military radar systems since they are the most used, most complex, and most interesting of the pulse Doppler radars; however, ground-based and non-military systems are also included. It covers the fundamental science, signal processing, hardware issues, systems design and case studies of typical systems. It will be a useful resource for engineers of all types (hardware, software and systems), academics, post-graduate students, scientists in radar and radar electronic warfare sectors and milit

  5. Pulse Synchronization System (PSS)

    1977-06-01

    This document is intended to serve as an operations manual, as well as a documentation of the backup analyses pertinent to the design as delivered. A history of earlier unsuccessful versions of the Pulse Synchronization System (PSS) is not included. The function of the PSS is to synchronize the time of arrival at the fusion target of laser pulses that are propagated through the 20 amplifier chains of the SHIVA laser. The positional accuracy requirement is +-1.5 mm (+-5 psec), and is obtained by the PSS with a wide margin factor

  6. Physical model of reactor pulse

    Petrovic, A.; Ravnik, M.

    2004-01-01

    Pulse experiments have been performed at J. Stefan Institute TRIGA reactor since 1991. In total, more than 130 pulses have been performed. Extensive experimental information on the pulse physical characteristics has been accumulated. Fuchs-Hansen adiabatic model has been used for predicting and analysing the pulse parameters. The model is based on point kinetics equation, neglecting the delayed neutrons and assuming constant inserted reactivity in form of step function. Deficiencies of the Fuchs-Hansen model and systematic experimental errors have been observed and analysed. Recently, the pulse model was improved by including the delayed neutrons and time dependence of inserted reactivity. The results explain the observed non-linearity of the pulse energy for high pulses due to finite time of pulse rod withdrawal and the contribution of the delayed neutrons after the prompt part of the pulse. The results of the improved model are in good agreement with experimental results. (author)

  7. Parallel Lines

    James G. Worner

    2017-05-01

    Full Text Available James Worner is an Australian-based writer and scholar currently pursuing a PhD at the University of Technology Sydney. His research seeks to expose masculinities lost in the shadow of Australia’s Anzac hegemony while exploring new opportunities for contemporary historiography. He is the recipient of the Doctoral Scholarship in Historical Consciousness at the university’s Australian Centre of Public History and will be hosted by the University of Bologna during 2017 on a doctoral research writing scholarship.   ‘Parallel Lines’ is one of a collection of stories, The Shapes of Us, exploring liminal spaces of modern life: class, gender, sexuality, race, religion and education. It looks at lives, like lines, that do not meet but which travel in proximity, simultaneously attracted and repelled. James’ short stories have been published in various journals and anthologies.

  8. A signal combining technique based on channel shortening for cooperative sensor networks

    Hussain, Syed Imtiaz; Alouini, Mohamed-Slim; Hasna, Mazen Omar

    2010-01-01

    The cooperative relaying process needs proper coordination among the communicating and the relaying nodes. This coordination and the required capabilities may not be available in some wireless systems, e.g. wireless sensor networks where the nodes are equipped with very basic communication hardware. In this paper, we consider a scenario where the source node transmits its signal to the destination through multiple relays in an uncoordinated fashion. The destination can capture the multiple copies of the transmitted signal through a Rake receiver. We analyze a situation where the number of Rake fingers N is less than that of the relaying nodes L. In this case, the receiver can combine N strongest signals out of L. The remaining signals will be lost and act as interference to the desired signal components. To tackle this problem, we develop a novel signal combining technique based on channel shortening. This technique proposes a processing block before the Rake reception which compresses the energy of L signal components over N branches while keeping the noise level at its minimum. The proposed scheme saves the system resources and makes the received signal compatible to the available hardware. Simulation results show that it outperforms the selection combining scheme. ©2010 IEEE.

  9. Palliative Sedation in Advanced Cancer Patients: Does it Shorten Survival Time? - A Systematic Review.

    Barathi, B; Chandra, Prabha S

    2013-01-01

    Patients with advanced cancer often suffer from multiple refractory symptoms in the terminal phase of their life. Palliative sedation is one of the few ways to relieve this refractory suffering. This systematic review investigated the effect of palliative sedation on survival time in terminally ill cancer patients. Six electronic databases were searched for both prospective and retrospective studies which evaluated the effect of palliative sedation on survival time. Only those studies which had a comparison group that did not receive palliative sedation were selected for the review. Abstracts of all retrieved studies were screened to include the most relevant studies and only studies which met inclusion criteria were selected. References of all retrieved studies were also screened for relevant studies. Selected studies were assessed for quality and data extraction was done using the structured data extraction form. Eleven studies including four prospective and seven retrospective studies were identified. Mean survival time (MST) was measured as the time from last admission until death. A careful analysis of the results of all the 11 studies indicated that MST of sedated and non-sedated group was not statistically different in any of the studies. This systematic review supports the fact that palliative sedation does not shorten survival in terminally ill cancer patients. However, this conclusion needs to be taken with consideration of the methodology, study design, and the population studied of the included studies in this review.

  10. A diversity compression and combining technique based on channel shortening for cooperative networks

    Hussain, Syed Imtiaz

    2012-02-01

    The cooperative relaying process with multiple relays needs proper coordination among the communicating and the relaying nodes. This coordination and the required capabilities may not be available in some wireless systems where the nodes are equipped with very basic communication hardware. We consider a scenario where the source node transmits its signal to the destination through multiple relays in an uncoordinated fashion. The destination captures the multiple copies of the transmitted signal through a Rake receiver. We analyze a situation where the number of Rake fingers N is less than that of the relaying nodes L. In this case, the receiver can combine N strongest signals out of L. The remaining signals will be lost and act as interference to the desired signal components. To tackle this problem, we develop a novel signal combining technique based on channel shortening principles. This technique proposes a processing block before the Rake reception which compresses the energy of L signal components over N branches while keeping the noise level at its minimum. The proposed scheme saves the system resources and makes the received signal compatible to the available hardware. Simulation results show that it outperforms the selection combining scheme. © 2012 IEEE.

  11. Reliability and consistency of plantarflexor stretch-shortening cycle function using an adapted force sledge apparatus

    Furlong, Laura-Anne M; Harrison, Andrew J

    2013-01-01

    There are various limitations to existing methods of studying plantarflexor stretch-shortening cycle (SSC) function and muscle-tendon unit (MTU) mechanics, predominantly related to measurement validity and reliability. This study utilizes an innovative adaptation to a force sledge which isolates the plantarflexors and ankle for analysis. The aim of this study was to determine the sledge loading protocol to be used, most appropriate method of data analysis and measurement reliability in a group of healthy, non-injured subjects. Twenty subjects (11 males, 9 females; age: 23.5 ±2.3 years; height: 1.73 ±0.08 m; mass: 74.2 ±11.3 kg) completed 11 impacts at five different loadings rated on a scale of perceived exertion from 1 to 5, where 5 is a loading that the subject could only complete the 11 impacts using the adapted sledge. Analysis of impacts 4–8 or 5–7 using loading 2 provided consistent results that were highly reliable (single intra-class correlation, ICC > 0.85, average ICC > 0.95) and replicated kinematics found in hopping and running. Results support use of an adapted force sledge apparatus as an ecologically valid, reliable method of investigating plantarflexor SSC function and MTU mechanics in a dynamic controlled environment. (paper)

  12. A Phenomenological Model and Validation of Shortening Induced Force Depression during Muscle Contractions

    McGowan, C.P.; Neptune, R.R.; Herzog, W.

    2009-01-01

    History dependent effects on muscle force development following active changes in length have been measured in a number of experimental studies. However, few muscle models have included these properties or examined their impact on force and power output in dynamic cyclic movements. The goal of this study was to develop and validate a modified Hill-type muscle model that includes shortening induced force depression and assess its influence on locomotor performance. The magnitude of force depression was defined by empirical relationships based on muscle mechanical work. To validate the model, simulations incorporating force depression were developed to emulate single muscle in situ and whole muscle group leg extension experiments. There was excellent agreement between simulation and experimental values, with in situ force patterns closely matching the experimental data (average RMS error pedaling with and without force depression were generated. Force depression decreased maximum crank power by 20% – 40%, depending on the relationship between force depression and muscle work used. These results indicate that force depression has the potential to substantially influence muscle power output in dynamic cyclic movements. However, to fully understand the impact of this phenomenon on human movement, more research is needed to characterize the relationship between force depression and mechanical work in large muscles with different morphologies. PMID:19879585

  13. Fatigue and muscle-tendon stiffness after stretch-shortening cycle and isometric exercise.

    Toumi, Hechmi; Poumarat, Georges; Best, Thomas M; Martin, Alain; Fairclough, John; Benjamin, Mike

    2006-10-01

    The purpose of the present study was to compare vertical jump performance after 2 different fatigue protocols. In the first protocol, subjects performed consecutive sets of 10 repetitions of stretch-shortening cycle (SSC) contractions. In the second protocol, successive sets of 10 repetitions of isometric contractions were performed for 10 s with the knee at 90 degrees of flexion. The exercises were stopped when the subjects failed to reach 50% of their maximum voluntary isometric contractions. Maximal isometric force and maximal concentric power were assessed by performing supine leg presses, squat jumps, and drop jumps. Surface EMG was used to determine changes in muscle activation before and after fatigue. In both groups, the fatigue exercises reduced voluntary isometric force, maximal concentric power, and drop jump performance. Kinematic data showed a decrease in knee muscle-tendon stiffness accompanied by a lengthened ground contact time. EMG analysis showed that the squat and drop jumps were performed similarly before and after the fatigue exercise for both groups. Although it was expected that the stiffness would decrease more after SSC than after isometric fatigue (as a result of a greater alteration of the reflex sensitivity SSC), our results showed that both protocols had a similar effect on knee muscle stiffness during jumping exercises. Both fatigue protocols induced muscle fatigue, and the decrease in jump performance was linked to a decrease in the strength and stiffness of the knee extensor muscles.

  14. Increased Rate of NAD Metabolism Shortens Plant Longevity by Accelerating Developmental Senescence in Arabidopsis.

    Hashida, Shin-Nosuke; Itami, Taketo; Takahara, Kentaro; Hirabayashi, Takayuki; Uchimiya, Hirofumi; Kawai-Yamada, Maki

    2016-11-01

    NAD is a well-known co-enzyme that mediates hundreds of redox reactions and is the basis of various processes regulating cell responses to different environmental and developmental cues. The regulatory mechanism that determines the amount of cellular NAD and the rate of NAD metabolism remains unclear. We created Arabidopsis thaliana plants overexpressing the NAD synthase (NADS) gene that participates in the final step of NAD biosynthesis. NADS overexpression enhanced the activity of NAD biosynthesis but not the amounts of NAD + , NADH, NADP + or NADPH. However, the amounts of some intermediates were elevated, suggesting that NAD metabolism increased. The NAD redox state was greatly facilitated by an imbalance between NAD generation and degradation in response to bolting. Metabolite profiling and transcriptional analysis revealed that the drastic modulation of NAD redox homeostasis increased tricarboxylic acid flux, causing the ectopic generation of reactive oxygen species. Vascular bundles suffered from oxidative stress, leading to a malfunction in amino acid and organic acid transportation that caused early wilting of the flower stalk and shortened plant longevity, probably due to malnutrition. We concluded that the mechanism regulating the balance between NAD synthesis and degradation is important in the systemic plant response to developmental cues during the growth-phase transition. © The Author 2016. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  15. Simulative Global Warming Negatively Affects Cotton Fiber Length through Shortening Fiber Rapid Elongation Duration.

    Dai, Yanjiao; Yang, Jiashuo; Hu, Wei; Zahoor, Rizwan; Chen, Binglin; Zhao, Wenqing; Meng, Yali; Zhou, Zhiguo

    2017-08-23

    Global warming could possibly increase the air temperature by 1.8-4.0 °C in the coming decade. Cotton fiber is an essential raw material for the textile industry. Fiber length, which was found negatively related to the excessively high temperature, determines yarn quality to a great extent. To investigate the effects of global warming on cotton fiber length and its mechaism, cottons grown in artificially elevated temperature (34.6/30.5 °C, T day /T night ) and ambient temperature (31.6/27.3 °C) regions have been investigated. Becaused of the high sensitivities of enzymes V-ATPase, PEPC, and genes GhXTH1 and GhXTH2 during fiber elongation when responding to high temperature stress, the fiber rapid elongation duration (FRED) has been shortened, which led to a significant suppression on final fiber length. Through comprehensive analysis, T night had a great influence on fiber elongation, which means T n could be deemed as an ideal index for forecasting the degree of high temperature stress would happen to cotton fiber property in future. Therefore, we speculate the global warming would bring unfavorable effects on cotton fiber length, which needs to take actions in advance for minimizing the loss in cotton production.

  16. A signal combining technique based on channel shortening for cooperative sensor networks

    Hussain, Syed Imtiaz

    2010-06-01

    The cooperative relaying process needs proper coordination among the communicating and the relaying nodes. This coordination and the required capabilities may not be available in some wireless systems, e.g. wireless sensor networks where the nodes are equipped with very basic communication hardware. In this paper, we consider a scenario where the source node transmits its signal to the destination through multiple relays in an uncoordinated fashion. The destination can capture the multiple copies of the transmitted signal through a Rake receiver. We analyze a situation where the number of Rake fingers N is less than that of the relaying nodes L. In this case, the receiver can combine N strongest signals out of L. The remaining signals will be lost and act as interference to the desired signal components. To tackle this problem, we develop a novel signal combining technique based on channel shortening. This technique proposes a processing block before the Rake reception which compresses the energy of L signal components over N branches while keeping the noise level at its minimum. The proposed scheme saves the system resources and makes the received signal compatible to the available hardware. Simulation results show that it outperforms the selection combining scheme. ©2010 IEEE.

  17. Psychometric analysis in support of shortening the Scale for the Assessment of Negative Symptoms.

    Levine, Stephen Z; Leucht, Stefan

    2013-09-01

    Despite recent emphasis on the measurement and treatment of negative symptoms, studies of the Scale for the Assessment of Negative Symptoms (SANS) identify different symptom clusters, offer mixed support for its psychometric properties and suggest that it is shortened. The current study objective is to examine the psychometric properties of the SANS and the feasibility of a short research version of the SANS. Data were re-analyzed from three clinical trials that compared placebo and amisulpride to 60 days. Participants had chronic schizophrenia and predominantly negative symptoms (n=487). Baseline data were examined with exploratory factor analysis and Item Response Theory (IRT) to identify a short SANS. The short and original SANS were compared: with confirmatory factor analysis at endpoint; and on symptom response with mixed modeling to compare. Results showed that at baseline the SANS consisted of three factors labeled Affective-flattening, Asociality and Alogia-inattentiveness. IRT suggested a short SANS with 11 items and 3 response options. Comparisons of the original and short SANS showed: the short version was a better fit to the data based on confirmatory factor analysis at endpoint; similar significant (pnegative symptoms in chronic schizophrenia in research settings. Copyright © 2012 Elsevier B.V. and ECNP. All rights reserved.

  18. Respiratory acidosis prolongs, while alkalosis shortens, the duration and recovery time of vecuronium in humans.

    Yamauchi, Masanori; Takahashi, Hiromi; Iwasaki, Hiroshi; Namiki, Akiyoshi

    2002-03-01

    To determine the effects of respiratory acidosis and alkalosis by mechanical ventilation on the onset, duration, and recovery times of vecuronium. Randomized, prospective study. Operating rooms in the Sapporo Medical University Hospital and Kitami Red Cross Hospital. 90 ASA physical status I and II patients undergoing lower abdominal surgery. Patients were randomly allocated to one of three groups by arterial carbon dioxide tension level (PaCO2; mmHg) after induction: hyperventilation group (PaCO2 = 25-35), normoventilation group (PaCO2 = 35-45), and hypoventilation group (PaCO2 = 45-55). Anesthesia was maintained by spinal block with inhalation of 50% to 66% nitrous oxide in oxygen and intermittent intravenous administration of fentanyl and midazolam with tracheal intubation. After vecuronium 0.08 mg/kg was given, onset, duration, and recovery time were measured by mechanomyography (Biometer Myograph 2,000, Odense, Denmark). There were significant differences in the duration and recovery time of vecuronium among the normoventilation group (12.7 +/- 3.3 min and 11.8 +/- 2.8 min, respectively), the hyperventilation group (10.6 +/- 3.5 min and 9.2 +/- 2.7 min, respectively; p respiratory acidosis and shortened in respiratory alkalosis.

  19. Measurement characteristics of the childhood Asthma-Control Test and a shortened, child-only version.

    Bime, Christian; Gerald, Joe K; Wei, Christine Y; Holbrook, Janet T; Teague, William G; Wise, Robert A; Gerald, Lynn B

    2016-10-20

    The childhood Asthma-Control Test (C-ACT) is validated for assessing asthma control in paediatric asthma. Among children aged 4-11 years, the C-ACT requires the simultaneous presence of both parent and child. There is an unmet need for a tool that can be used to assess asthma control in children when parents or caregivers are not present such as in the school setting. We assessed the psychometric properties and estimated the minimally important difference (MID) of the C-ACT and a modified version, comprising only the child responses (C-ACTc). Asthma patients aged 6-11 years (n=161) from a previously completed multicenter randomised trial were included. Demographic information, spirometry and questionnaire scores were obtained at baseline and during follow-up. Participants or their guardians kept a daily asthma diary. Internal consistency reliabilities of the C-ACT and C-ACTc were 0.76 and 0.67 (Cronbach's α), respectively. Test-retest reliabilities of the C-ACT and C-ACTc were 0.72 and 0.66 (intra-class correlation), respectively. Significant correlations were noted between C-ACT scores and ACQ scores (Spearman's correlation r=-0.56, 95% CI (-0.66, -0.44), Pasthma patients aged 6-11 years, the C-ACT had good psychometric properties. The psychometric properties of a shortened child-only version (C-ACTc), although acceptable, are not as strong.

  20. Palliative sedation in advanced cancer patients: Does it shorten survival time? - A systematic review

    B Barathi

    2013-01-01

    Full Text Available Background: Patients with advanced cancer often suffer from multiple refractory symptoms in the terminal phase of their life. Palliative sedation is one of the few ways to relieve this refractory suffering. Objectives: This systematic review investigated the effect of palliative sedation on survival time in terminally ill cancer patients. Materials and Methods: Six electronic databases were searched for both prospective and retrospective studies which evaluated the effect of palliative sedation on survival time. Only those studies which had a comparison group that did not receive palliative sedation were selected for the review. Abstracts of all retrieved studies were screened to include the most relevant studies and only studies which met inclusion criteria were selected. References of all retrieved studies were also screened for relevant studies. Selected studies were assessed for quality and data extraction was done using the structured data extraction form. Results: Eleven studies including four prospective and seven retrospective studies were identified. Mean survival time (MST was measured as the time from last admission until death. A careful analysis of the results of all the 11 studies indicated that MST of sedated and non-sedated group was not statistically different in any of the studies. Conclusion: This systematic review supports the fact that palliative sedation does not shorten survival in terminally ill cancer patients. However, this conclusion needs to be taken with consideration of the methodology, study design, and the population studied of the included studies in this review.

  1. A systematic review of prosthetic restoration in patients with shortened dental arches

    Kenji Fueki

    2011-08-01

    Full Text Available The literature regarding the effect of prosthetic restoration in patients having distal extension edentulous space in posterior area (shortened dental arch: SDA is reviewed in the following article. Information retrieval followed a systematic approach using PubMed. Articles in English published between 1966 and March 2011 describing the outcome of treatment with various prostheses were evaluated. From the search results of 98 articles, 21 articles met the inclusion criteria. Treatment with removable partial dentures (RPDs improved masticatory function, patient satisfaction and oral health-related quality of life (OHRQoL. However, no significant difference was found in the outcomes between patients with RPDs and with cantilever fixed partial dentures (CFPDs. Caries developed more frequently after treatment with RPDs than CFPDs. The time to survival for CFPDs was not longer than that for RPDs, while more visits to maintain RPDs were required than for CFPDs. No significant difference was found in masticatory function, OHRQoL, and occlusal stability between patients with RPDs and those without restoration of missing molars. Consequently, treatment with RPDs for SDA seems to be less advantageous than CFPDs or no restoration for missing molars. Further research is required to validate treatment with implant-supported fixed partial dentures for SDA.

  2. Exome sequencing links mutations in PARN and RTEL1 with familial pulmonary fibrosis and telomere shortening.

    Stuart, Bridget D; Choi, Jungmin; Zaidi, Samir; Xing, Chao; Holohan, Brody; Chen, Rui; Choi, Mihwa; Dharwadkar, Pooja; Torres, Fernando; Girod, Carlos E; Weissler, Jonathan; Fitzgerald, John; Kershaw, Corey; Klesney-Tait, Julia; Mageto, Yolanda; Shay, Jerry W; Ji, Weizhen; Bilguvar, Kaya; Mane, Shrikant; Lifton, Richard P; Garcia, Christine Kim

    2015-05-01

    Idiopathic pulmonary fibrosis (IPF) is an age-related disease featuring progressive lung scarring. To elucidate the molecular basis of IPF, we performed exome sequencing of familial kindreds with pulmonary fibrosis. Gene burden analysis comparing 78 European cases and 2,816 controls implicated PARN, an exoribonuclease with no previous connection to telomere biology or disease, with five new heterozygous damaging mutations in unrelated cases and none in controls (P = 1.3 × 10(-8)); mutations were shared by all affected relatives (odds in favor of linkage = 4,096:1). RTEL1, an established locus for dyskeratosis congenita, harbored significantly more new damaging and missense variants at conserved residues in cases than in controls (P = 1.6 × 10(-6)). PARN and RTEL1 mutation carriers had shortened leukocyte telomere lengths, and we observed epigenetic inheritance of short telomeres in family members. Together, these genes explain ~7% of familial pulmonary fibrosis and strengthen the link between lung fibrosis and telomere dysfunction.

  3. Production and application of pulsed slow-positron beam using an electron LINAC

    Yamazaki, Tetsuo; Suzuki, Ryoichi; Ohdaira, Toshiyuki; Mikado, Tomohisa [Electrotechnical Lab., Tsukuba, Ibaraki (Japan); Kobayashi, Yoshinori

    1997-03-01

    Slow-positron beam is quite useful for non-destructive material research. At the Electrotechnical Laboratory (ETL), an intense slow positron beam line by exploiting an electron linac has been constructed in order to carry out various experiments on material analysis. The beam line can generates pulsed positron beams of variable energy and of variable pulse period. Many experiments have been carried out so far with the beam line. In this paper, various capability of the intense pulsed positron beam is presented, based on the experience at the ETL, and the prospect for the future is discussed. (author)

  4. Characterization of the pulse plasma source

    Milosavljevic, V; Karkari, S K; Ellingboe, A R

    2007-01-01

    Characterization of the pulse plasma source through the determination of the local thermodynamic equilibrium (LTE) threshold is described. The maximum electron density measured at the peak in discharge current is determined by the width of the He II Paschen alpha spectral line, and the electron temperature is determined from the ratios of the relative intensities of spectral lines emitted from successive ionized stages of atoms. The electron density and temperature maximum values are measured to be 1.3 x 10 17 cm -3 and 19 000 K, respectively. These are typical characteristics for low-pressure, pulsed plasma sources for input energy of 15.8 J at 130 Pa pressure in helium-argon mixture. The use of LTE-based analysis of the emission spectra is justified by measurement of the local plasma electron density at four positions in the discharge tube using a floating hairpin resonance probe. The hairpin resonance probe data are collected during the creation and decay phases of the pulse. From the spatio-temporal profile of the plasma density a 60 μs time-window during which LTE exists throughout the entire plasma source is determined

  5. Insect disinfestation of pulses by irradiation

    Bhuiya, A.D.; Ahmed, M.; Rezaur, R.; Seal, D.R.; Nahar, G.; Islam, M.M.; Islam, M.S.

    1985-01-01

    Studies were carried out on four varieties of pulses, namely, mosur or lentil (Lens esculenta), mung (Phaseolus aureus), chola or gram (Cirecer aricitinum), and mashkalai (Phaseolus radiatus). Two major burchid betles, Callosobruchus chinensis (L.) and Callosobruchus analis (Fab.), were found to infest different varieties of pulses. Radiation sensitivity of the two pulse beetles was determined at different developmental stages (i.e., eggs, larvae, and pupae). Emergence of adults from eggs totally stopped at a dose of 0.04 kGy. Doses of 0.28 and 0.32 kGy, respectively, were required for complete inhibition of adult emergence from irradiated fourth instar larvae of C. analis and C. chinensis. Studies revealed that the experimental gram was heavily infested (65-91 percent) as compared to other pulses after 8 months of storage in all packaging materials used (gunny bag, gunny bag lined with polyethylene, polyethylene and polyvinyl chloride bags). Mashkalai showed insignificant damage (2-5 percent) by the insects. Reinfestation in the treated products was observed in polyethylene and gunny bags

  6. Pulse power modulators - an overview

    Venkatramani, N.

    2006-01-01

    Pulse power modulators are electronic devices to provide, high voltage, high current, power bursts. Ideally, a modulator, with the means to shape and control the pulses, acts as a switch between a high voltage power supply and its load. This article gives an overview of the pulse power modulators: starting with the basics of pulse and modulation, it covers modulation topologies, different types of modulators, major subsystems and pulse measurement techniques. The various applications of pulse power modulators and the recent trends have been included at the end. (author)

  7. Micro-Sugar-Snap and -Wire-Cut Cookie Baking with Trans- and Zero-Trans-Fat Shortenings

    The effect of trans- and zero-trans-fat shortenings on cookie-baking performance was evaluated, using the two AACC micro-cookie-baking methods. Regardless of fat type, sugar-snap cookies made with a given flour were larger in diameter, smaller in height, and greater in weight loss during baking tha...

  8. Higher education delays and shortens cognitive impairment: a multistate life table analysis of the US Health and Retirement Study

    Reuser, M.; Willekens, F.J.C.; Bonneux, L.G.A.

    2011-01-01

    Improved health may extend or shorten the duration of cognitive impairment by postponing incidence or death. We assess the duration of cognitive impairment in the US Health and Retirement Study (1992–2004) by self reported BMI, smoking and levels of education in men and women and three ethnic

  9. Shortened version of the work ability index to identify workers at risk of long-term sickness absence

    Schouten, Lianne S.; Bultmann, Ute; Heymans, Martijn W.; Joling, Catelijne I.; Twisk, Jos W. R.; Roelen, Corne A. M.

    2016-01-01

    Background: The Work Ability Index (WAI) identifies non-sicklisted workers at risk of future long-term sickness absence (LTSA). The WAI is a complicated instrument and inconvenient for use in large-scale surveys. We investigated whether shortened versions of the WAI identify non-sicklisted workers

  10. Diagnostic accuracy of the original 30-item and shortened versions of the Geriatric Depression Scale in nursing home patients

    Jongenelis, K; Eisses, AMH; Gerritsen, DL; Beekman, ATF; Kluiter, H; Ribbe, MW

    Objective To determine the diagnostic accuracy of the 30-item and shortened versions of the Geriatric Depression Scale (GDS) in diagnosing depression in older nursing home patients. Method Three hundred and thirty-three older nursing home patients participated in a prospective cross-sectional study

  11. Experimental investigation of impulse response shortening for low-complexity MLSE of a 112-Gbit/s PAM-4 transceiver

    van der Heide, S.; Eiselt, N.; Griesser, H.; Olmos, J. J.V.; Tafur Monroy, I.; Okonkwo, C.

    2016-01-01

    An optimized channel shortening method for reduced complexity MLSE detection enables the compensation of severe inter-symbol interference. Experimental investigations demonstrate the benefit on the performance for a severely bandwidth limited 112-Gbit/s PAM-4 transmission system with residual

  12. Experimental investigation of impulse response shortening for low-complexity MLSE of a 112-Gbit/s PAM-4 transceiver

    Van Der Heide, Sjoerd; Eiselt, Nicklas; Griesser, Helmut

    2016-01-01

    An optimized channel shortening method for reduced complexity MLSE detection enables the compensation of severe inter-symbol interference. Experimental investigations demonstrate the benefit on the performance for a severely bandwidth limited 112-Gbit/s PAM-4 transmission system with residual chr...

  13. Effects of shortening the dry period of dairy cows on milk production, energy balance, health, and fertility: A systemtic review

    Knegsel, van A.T.M.; Drift, van der S.G.A.; Cermáková, J.; Kemp, B.

    2013-01-01

    A dry period of 6–8 weeks for dairy cows is generally thought to maximise milk production in the next lactation. However, the value of such a long dry period is increasingly questioned. In particular, shortening the dry period shifts milk production from the critical period after calving to the

  14. Diagnostic accuracy of the original 30-item and shortened versions of the Geriatric Depression Scale in nursing home patients

    Jongenelis, K; Eisses, AMH; Gerritsen, DL; Beekman, ATF; Kluiter, H; Ribbe, MW

    2005-01-01

    Objective To determine the diagnostic accuracy of the 30-item and shortened versions of the Geriatric Depression Scale (GDS) in diagnosing depression in older nursing home patients. Method Three hundred and thirty-three older nursing home patients participated in a prospective cross-sectional study

  15. One-stage lengthening using a locked nailing technique for distal femoral shaft nonunions associated with shortening.

    Wu, Chi-Chuan; Lee, Zhon-Liau

    2004-02-01

    To assess the effectiveness of a one-stage lengthening using a locked nail technique for the treatment of distal femoral shaft nonunions associated with shortening. Retrospective. University hospital. During a 6-year period, 36 distal femoral shaft nonunions associated with shortening (>1.5 cm) were treated by the one-stage lengthening technique. Indications for this technique were distal femoral shaft aseptic or quiescent infected nonunions, 1.5-5 cm shortening, and a fracture level suitable for the insertion of two distal locked screws. The surgical technique involved skeletal traction using the femoral condyle, local débridement, lengthening by lengthening was 2.5 cm (range 1.5-3.5 cm). One-stage lengthening using the locked nailing technique to treat distal femoral shaft nonunions associated with shortening can achieve a high success rate and low complication rate. The key to successful treatment is the patient's complete cooperation with strictly protected weight bearing until the fracture has healed.

  16. The development of the EORTC QLQ-C15-PAL: a shortened questionnaire for cancer patients in palliative care

    Groenvold, Mogens; Petersen, Morten Aa; Aaronson, Neil K.; Arraras, Juan I.; Blazeby, Jane M.; Bottomley, Andrew; Fayers, Peter M.; de Graeff, Alexander; Hammerlid, Eva; Kaasa, Stein; Sprangers, Mirjam A. G.; Bjorner, Jakob B.

    2006-01-01

    This study aimed at developing a shortened version of the EORTC QLQ-C30, one of the most widely used health-related quality of life questionnaires in oncology, for palliative care research. The study included interviews with 41 patients and 66 health care professionals in palliative care to

  17. Magnitude of crustal shortening and structural framework of the easternmost Himalayan orogen, northern Indo-Burma Ranges of northeastern India

    Haproff, P. J.; Yin, A.

    2016-12-01

    Along-strike variation in crustal shortening throughout the Himalayan orogen has been attributed to (1) diachronous, eastward-increasing convergence, or (2) localized controls including pre-collisional stratigraphic configuration and climate. In this study, we present new geologic maps and balanced cross-sections across the easternmost segment of the Himalayan orogen, the N-S-trending N. Indo-Burma Ranges of northeastern India. First order structures are NE-dipping, km-wide ductile thrust shear zones with mylonitic fabrics indicating top-to-the SW motion. Major structures include the Mayodia klippe and Hunli window, generated during folding of the SW-directed Tidding thrust and duplexing of Lesser Himalayan rocks (LHS) at depth. Reconstruction of two balanced cross-sections yields minimum shortening estimates of 70% (48 km) and 71% (133 km), respectively. The widths of the orogen for each transect are 21 km and 54 km, respectively. Our percent strain values are comparable to that of western Arunachal Himalaya, reflecting eastward-increasing strain due to counterclockwise rotation of India during convergence or along-strike variation in India's subduction angle. However, shortening magnitudes much less than that of the Sikkim (641 km), Bhutan (414-615 km), and western Arunachal Himalaya (515-775 km) could signal eastward increasing shortening of a unique Himalayan stratigraphic framework, evidenced by few GHC rocks, absence of Tethyan strata, and an extensive subduction mélange and forearc complex.

  18. Higher education delays and shortens cognitive impairment : A multistate life table analysis of the US Health and Retirement Study

    Reuser, Mieke; Willekens, Frans J.; Bonneux, Luc

    Improved health may extend or shorten the duration of cognitive impairment by postponing incidence or death. We assess the duration of cognitive impairment in the US Health and Retirement Study (1992-2004) by self reported BMI, smoking and levels of education in men and women and three ethnic

  19. Enhanced Corticospinal Excitability and Volitional Drive in Response to Shortening and Lengthening Strength Training and Changes Following Detraining

    Tallent, Jamie; Goodall, Stuart; Gibbon, Karl C.; Hortobagyi, Tibor; Howatson, Glyn

    2017-01-01

    There is a limited understanding of the neurological adaptations responsible for changes in strength following shortening and lengthening resistance training and subsequent detraining. The aim of the study was to investigate differences in corticospinal and spinal responses to resistance training of

  20. MHD-Stabilization of Axisymmetric Mirror Systems Using Pulsed ECRH

    Post, R.F.

    2010-01-01

    This paper, part of a continuing study of means for the stabilization of MHD interchange modes in axisymmertric mirror-based plasma confinement systems, is aimed at a preliminary look at a technique that would employ a train of plasma pressure pulses produced by ECRH to accomplish the stabilization. The purpose of using sequentially pulsed ECRH rather than continuous-wave ECRH is to facilitate the localization of the heated-electron plasma pulses in regions of the magnetic field with a strong positive field-line curvature, e. g. in the 'expander' region of the mirror magnetic field, outside the outermost mirror, or in other regions of the field with positive field-line curvature. The technique proposed, of the class known as 'dynamic stabilization,' relies on the time-averaged effect of plasma pressure pulses generated in regions of positive field-line curvature to overcome the destabilizing effect of plasma pressure in regions of negative field-line curvature within the confinement region. As will also be discussed in the paper, the plasma pulses, when produced in regions of the confining having a negative gradient, create transient electric potentials of ambipolar origin, an effect that was studied in 1964 in The PLEIDE experiment in France. These electric fields preserve the localization of the hot-electron plasma pulses for a time determined by ion inertia. It is suggested that it may be possible to use this result of pulsed ECRH not only to help to stabilize the plasma but also to help plug mirror losses in a manner similar to that employed in the Tandem Mirror.

  1. A trial of ignition innovation of gasoline engine by nanosecond pulsed low temperature plasma ignition

    Shiraishi, Taisuke; Urushihara, Tomonori; Gundersen, Martin

    2009-01-01

    Application of nanosecond pulsed low temperature plasma as an ignition technique for automotive gasoline engines, which require a discharge under conditions of high back pressure, has been studied experimentally using a single-cylinder engine. The nanosecond pulsed plasma refers to the transient (non-equilibrated) phase of a plasma before the formation of an arc discharge; it was obtained by applying a high voltage with a nanosecond pulse (FWHM of approximately 80 or 25 ns) between coaxial cylindrical electrodes. It was confirmed that nanosecond pulsed plasma can form a volumetric multi-channel streamer discharge at an energy consumption of 60 mJ cycle -1 under a high back pressure of 1400 kPa. It was found that the initial combustion period was shortened compared with the conventional spark ignition. The initial flame visualization suggested that the nanosecond pulsed plasma ignition results in the formation of a spatially dispersed initial flame kernel at a position of high electric field strength around the central electrode. It was observed that the electric field strength in the air gap between the coaxial cylindrical electrodes was increased further by applying a shorter pulse. It was also clarified that the shorter pulse improved ignitability even further.

  2. A trial of ignition innovation of gasoline engine by nanosecond pulsed low temperature plasma ignition

    Shiraishi, Taisuke; Urushihara, Tomonori; Gundersen, Martin

    2009-07-01

    Application of nanosecond pulsed low temperature plasma as an ignition technique for automotive gasoline engines, which require a discharge under conditions of high back pressure, has been studied experimentally using a single-cylinder engine. The nanosecond pulsed plasma refers to the transient (non-equilibrated) phase of a plasma before the formation of an arc discharge; it was obtained by applying a high voltage with a nanosecond pulse (FWHM of approximately 80 or 25 ns) between coaxial cylindrical electrodes. It was confirmed that nanosecond pulsed plasma can form a volumetric multi-channel streamer discharge at an energy consumption of 60 mJ cycle-1 under a high back pressure of 1400 kPa. It was found that the initial combustion period was shortened compared with the conventional spark ignition. The initial flame visualization suggested that the nanosecond pulsed plasma ignition results in the formation of a spatially dispersed initial flame kernel at a position of high electric field strength around the central electrode. It was observed that the electric field strength in the air gap between the coaxial cylindrical electrodes was increased further by applying a shorter pulse. It was also clarified that the shorter pulse improved ignitability even further.

  3. Proton Pulse Radiolysis

    Christensen, H C; Nilsson, G; Reitberger, T; Thuomas, K A

    1973-03-15

    A 5 MeV proton accelerator (Van de Graaff) has been used for pulse radiolysis of a number of organic gases and the transient spectra obtained from the alkanes methane, ethane, propane, n-butane and neopentane have tentatively been assigned to alkyl radicals. Some methodological aspects of this new technique are discussed

  4. Lectures on pulsed NMR

    Pines, A.

    1988-08-01

    These lectures discuss some recent developments in pulsed NMR, emphasizing fundamental principles with selected illustrative applications. Major topics covered include multiple-quantum spectroscopy, spin decoupling, the interaction of spins with a quantized field, adiabatic rapid passage, spin temperature and statistics of cross-polarization, coherent averaging, and zero field NMR. 32 refs., 56 figs

  5. Lectures on pulsed NMR

    Pines, A.

    1986-09-01

    These lectures discuss some recent developments in pulsed NMR, emphasizing fundamental principles with selected illustrative applications. Major topics covered include multiple-quantum spectroscopy, spin decoupling, the interaction of spins with a quantized field, adiabatic rapid passage, spin temperature and statistics of cross-polarization, coherent averaging, and zero field NMR. 55 figs

  6. Pulsed electric fields

    The concept of pulsed electric fields (PEF) was first proposed in 1967 to change the behavior or microorganisms. The electric field phenomenon was identified as membrane rupture theory in the 1980s. Increasing the membrane permeability led to the application of PEF assisted extraction of cellular co...

  7. Pulsed inductive HF laser

    Razhev, A M; Kargapol' tsev, E S [Institute of Laser Physics, Siberian Branch, Russian Academy of Sciences, Novosibirsk (Russian Federation); Churkin, D S; Demchuk, S V [Novosibirsk State University, Novosibirsk (Russian Federation)

    2016-03-31

    We report the results of experimentally investigated dependences of temporal, spectral and spatial characteristics of an inductive HF-laser generation on the pump conditions. Gas mixtures H{sub 2} – F{sub 2}(NF{sub 3} or SF6{sub 6}) and He(Ne) – H{sub 2} – F{sub 2}(NF{sub 3} or SF{sub 6}) were used as active media. The FWHM pulse duration reached 0.42 μs. This value corresponded to a pulsed power of 45 kW. For the first time, the emission spectrum of an inductive HF laser was investigated, which consisted of seven groups of bands with centres around the wavelengths of 2732, 2736, 2739, 2835, 2837, 2893 and 2913 nm. The cross section profile of the laser beam was a ring with a diameter of about 20 mm and width of about 5 mm. Parameters of laser operation in the repetitively pulsed regime were sufficiently stable. The amplitude instability of light pulses was no greater than 5% – 6%. (lasers)

  8. Pulse distortion, energy extraction, and ASE in an HF amplifier with angular multiplexing

    McGuire, E.J.

    1976-09-01

    It has been proposed that 1 ns pulses can be efficiently extracted from the e-beam initiated HF laser by angular multiplexing, i.e., filling the amplifier with the 1 ns pulses, 1 ns apart in time, each pulse at a slightly different angle; each pulse has an input intensity of 1 W/cm 2 per line and almost fills the amplifier. We have treated this in a one dimensional model, neglecting transverse amplified spontaneous emission. We conclude that the scheme is efficient, and that most of the pulses are amplified but not distorted. The first few pulses are distorted by transient effects and the last pulse has an enhanced tail. The ratio of peak pulse intensity to forward ASE at the output is 10 4 . We then include transverse ASE and find a drastically different situation. ASE saturates the inversion after a short time depending on pulse intensity (4 ns at I/sub o/ = 1 W/cm 2 , 7 ns at I/sub o/ = 100 W/cm 2 ). The saturation time is only weakly dependent on the transverse reflection coefficient. Calculations were done on an amplifier system designed for 10 KJ output. At an incident peak pulse intensity of 10 4 W/cm 2 -line (.77 MW/cm 2 for 77 lines) 2.5 KJ was obtained in amplified pulse energy, i.e., only 6 pulses of the 24 pulse train were fully amplified. The calculations indicate that double passing the pulse train through the amplifier would enhance the energy extracted

  9. Effect of applied voltage and inter-pulse delay in spark-assisted LIBS

    Robledo-Martinez, A.; Sobral, H.; Garcia-Villarreal, A.

    2018-06-01

    We report the results obtained in an investigation on the effect of the time delay between the laser and electrical pulses in a spark-assisted laser-induced breakdown spectroscopy (LIBS) experiment. The electrical discharge is produced by the discharge of a charged coaxial cable. This arrangement produces a fast unipolar current pulse (500 ns) that applies high power ( 600 kW) to the laser ablation plasma. The delay between the laser pulse and the electric pulse can be controlled at will in order to find the optimal time in terms of enhancement of the emitted lines. It was found that the application of the high voltage pulse enhances the ionic lines emitted by up to two orders of magnitude. An additional enhancement by a factor of 2-4 can be obtained delaying the application of the electric pulse by a time of 0.6-20 μs. In the tests it was noticed that the ionic lines were found to be clearly responsive to increments in the applied electric energy while the neutral lines did so marginally. Our results show that the intensification of the lines is mainly due to reheating of the ablation plasma as the application of the electrical pulse increments the temperature of the ablation plasma by about 50%. It is demonstrated that the present technique is an efficient way of intensifying the lines emitted without incurring in additional damage to the sample.

  10. 500 MW peak power degenerated optical parametric amplifier delivering 52 fs pulses at 97 kHz repetition rate.

    Rothhardt, J; Hädrich, S; Röser, F; Limpert, J; Tünnermann, A

    2008-06-09

    We present a high peak power degenerated parametric amplifier operating at 1030 nm and 97 kHz repetition rate. Pulses of a state-of-the art fiber chirped-pulse amplification (FCPA) system with 840 fs pulse duration and 410 microJ pulse energy are used as pump and seed source for a two stage optical parametric amplifier. Additional spectral broadening of the seed signal in a photonic crystal fiber creates enough bandwidth for ultrashort pulse generation. Subsequent amplification of the broadband seed signal in two 1 mm BBO crystals results in 41 microJ output pulse energy. Compression in a SF 11 prism compressor yields 37 microJ pulses as short as 52 fs. Thus, pulse shortening of more than one order of magnitude is achieved. Further scaling in terms of average power and pulse energy seems possible and will be discussed, since both concepts involved, the fiber laser and the parametric amplifier have the reputation to be immune against thermo-optical effects.

  11. Raytheon Stirling/pulse Tube Cryocooler Development

    Kirkconnell, C. S.; Hon, R. C.; Kesler, C. H.; Roberts, T.

    2008-03-01

    The first generation flight-design Stirling/pulse tube "hybrid" two-stage cryocooler has entered initial performance and environmental testing. The status and early results of the testing are presented. Numerous improvements have been implemented as compared to the preceding brassboard versions to improve performance, extend life, and enhance launch survivability. This has largely been accomplished by incorporating successful flight-design features from the Raytheon Stirling one-stage cryocooler product line. These design improvements are described. In parallel with these mechanical cryocooler development efforts, a third generation electronics module is being developed that will support hybrid Stirling/pulse tube and Stirling cryocoolers. Improvements relative to the second generation design relate to improved radiation hardness, reduced parts count, and improved vibration cancellation capability. Progress on the electronics is also presented.

  12. High power, repetitive stacked Blumlein pulse generators

    Davanloo, F; Borovina, D L; Korioth, J L; Krause, R K; Collins, C B [Univ. of Texas at Dallas, Richardson, TX (United States). Center for Quantum Electronics; Agee, F J [US Air Force Phillips Lab., Kirtland AFB, NM (United States); Kingsley, L E [US Army CECOM, Ft. Monmouth, NJ (United States)

    1997-12-31

    The repetitive stacked Blumlein pulse power generators developed at the University of Texas at Dallas consist of several triaxial Blumleins stacked in series at one end. The lines are charged in parallel and synchronously commuted with a single switch at the other end. In this way, relatively low charging voltages are multiplied to give a high discharge voltage across an arbitrary load. Extensive characterization of these novel pulsers have been performed over the past few years. Results indicate that they are capable of producing high power waveforms with rise times and repetition rates in the range of 0.5-50 ns and 1-300 Hz, respectively, using a conventional thyratron, spark gap, or photoconductive switch. The progress in the development and use of stacked Blumlein pulse generators is reviewed. The technology and the characteristics of these novel pulsers driving flash x-ray diodes are discussed. (author). 4 figs., 5 refs.

  13. Initial proto II pulsed power tests

    Johnson, D.L.

    1976-01-01

    The Proto II electron beam accelerator is being developed by Sandia Laboratories to study engineering and physics aspects of electron beam pellet fusion. Currently the Marx generator-water capacitor portion of Proto II is undergoing high voltage testing and timing measurements. Eight 112 kJ Marx generators form the primary energy storage system. Each Marx generator pulse charges two parallel 7.5 nF water capacitors to 3 MV. The water capacitors act as intermediate energy storage elements and will transfer their energy to the water insulated pulse-forming lines in 250 ns by means of eight SF 6 gas insulated, trigatron switches. Test data and design considerations of the trigger systems, Marx generators, water capacitors, and trigatron switches are presented

  14. A dispersion-balanced Discrete Fourier Transform of repetitive pulse sequences using temporal Talbot effect

    Fernández-Pousa, Carlos R.

    2017-11-01

    We propose a processor based on the concatenation of two fractional temporal Talbot dispersive lines with balanced dispersion to perform the DFT of a repetitive electrical sequence, for its use as a controlled source of optical pulse sequences. The electrical sequence is used to impart the amplitude and phase of a coherent train of optical pulses by use of a modulator placed between the two Talbot lines. The proposal has been built on a representation of the action of fractional Talbot effect on repetitive pulse sequences and a comparison with related results and proposals. It is shown that the proposed system is reconfigurable within a few repetition periods, has the same processing rate as the input optical pulse train, and requires the same technical complexity in terms of dispersion and pulse width as the standard, passive pulse-repetition rate multipliers based on fractional Talbot effect.

  15. VT Digital Line Graph Miscellaneous Transmission Lines

    Vermont Center for Geographic Information — (Link to Metadata) This datalayer is comprised of Miscellaineous Transmission Lines. Digital line graph (DLG) data are digital representations of cartographic...

  16. Multichannel computerized control system of current pulses in LIU-30 electron accelerator

    Gerasimov, A I; Kulgavchuk, V V; Pluzhnikov, A V

    2002-01-01

    In LIU-30 power linear pulsed induction electron accelerator (40 MeV, 10 kA, 25 ns) 288 radial lines with water insulation serve as energy accumulators and shapers of accelerating voltage pulses. The lines are charged simultaneously up to 500 kV using a system comprising 72 Arkadiev-Marx screened generators. To control parameter of synchronous pulses of charging current with up to 60 kA amplitude and 0.85 mu s duration in every of 72 charging circuits one applies a computer-aided system. Current pulse is recorded at output of every generator using the Rogowski coil signal from which via a cable line is transmitted to an analog-digital converter, is processed with 50 ns sampling and is recorded to a memory unit. Upon actuation of accelerator the signals are sequentially or selectively displayed and are compared with pulse typical shape

  17. A study of dentists’ preferences for the restoration of shortened dental arches with partial dentures

    Nassani, Mohammad Zakaria; Ibraheem, Shukran; Al-Hallak, Khaled Rateb; Ali El Khalifa, Mohammed Othman; Baroudi, Kusai

    2015-01-01

    Objective: This study aimed to use a utility method in order to assess dentists’ preferences for the restoration of shortened dental arches (SDAs) with partial dentures. Also, the impact of patient age and length of the SDA on dentists’ preferences for the partial dentures was investigated. Materials and Methods: Totally, 104 subjects holding a basic degree in dentistry and working as staff members in a private dental college in Saudi Arabia were interviewed and presented with 12 scenarios for patients of different ages and mandibular SDAs of varying length. Participants were asked to indicate on a standardized visual analog scale how they would value the health of the patient's mouth if the mandibular SDAs were restored with cobalt-chromium removable partial dentures (RPDs). Results: With a utility value of 0.0 representing the worst possible health state for a mouth and 1.0 representing the best, dentists’ average utility value of the RPD for the SDAs was 0.49 (sd= 0.15). Mean utility scores of the RPDs across the 12 SDA scenarios ranged between 0.35 and 0.61. RPDs that restored the extremely SDAs attracted the highest utility values and dentists’ utility of the RPD significantly increased with the increase in the number of missing posterior teeth. No significant differences in dentists’ mean utility values for the RPD were identified among SDA scenarios for patients of different ages. Conclusion: Restoration of the mandibular SDAs by RPDs is not a highly preferred treatment option among the surveyed group of dentists. Length of the SDA affects dentists’ preferences for the RPD, but patient age does not. PMID:26038647

  18. The randomized shortened dental arch study: tooth loss over five years.

    Walter, M H; Hannak, W; Kern, M; Mundt, T; Gernet, W; Weber, A; Wöstmann, B; Stark, H; Werner, D; Hartmann, S; Range, U; Jahn, F; Passia, N; Pospiech, P; Mitov, G; Brückner, J; Wolfart, S; Busche, E; Luthardt, R G; Heydecke, G; Marré, B

    2013-04-01

    The study was designed to provide clinical outcome data for two treatments of the shortened dental arch (SDA). In a multicenter randomized controlled clinical trial, patients with complete molar loss in one jaw were provided with either a partial removable dental prosthesis (PRDP) retained with precision attachments or treated according to the SDA concept preserving or restoring a premolar occlusion. No implants were placed. The primary outcome was tooth loss. Of 152 treated patients, 132 patients reached the 5-year examination. Over 5 years, 38 patients experienced tooth loss. For the primary outcome tooth loss, the Kaplan-Meier survival rates at 5 years were 0.74 (95% CI 0.64, 0.84) in the PRDP group and 0.74 (95% CI 0.63, 0.85) in the SDA group. For tooth loss in the study jaw, the survival rates at 5 years were 0.88 (95% CI 0.80, 0.95) in the PRDP group and 0.84 (95% CI 0.74, 0.93) in the SDA group. The differences were not significant. No Cox regression models of appropriate fit explaining tooth loss on the patient level could be found. The overall treatment goals of a sustainable oral rehabilitation and the avoidance of further tooth loss over longer periods were not reliably achievable. The influence of the type of prosthetic treatment on tooth loss might have been overestimated. Regarding our results, the patient's view will gain even more importance in the clinical decision between removable and fixed restorations in SDAs.

  19. Comparison of three shortened questionnaires for assessment of quality of life in advanced cancer.

    Chiu, Leonard; Chiu, Nicholas; Chow, Edward; Cella, David; Beaumont, Jennifer L; Lam, Henry; Popovic, Marko; Bedard, Gillian; Poon, Michael; Wong, Erin; Zeng, Liang; Bottomley, Andrew

    2014-08-01

    Quality of life (QoL) assessment questionnaires can be burdensome to advanced cancer patients, thus necessitating the need for shorter assessment instruments than traditionally available. We compare three shortened QoL questionnaires in regards to their characteristics, validity, and reliability. A literature search was conducted to identify studies that employed or discussed three abridged QoL questionnaires: the European Organization for Research and Treatment of Cancer Quality of Life Core 15-Palliative Care (EORTC QLQ-C15-PAL), the Functional Assessment of Cancer Therapy-General-7 (FACT-G7), and the Functional Assessment of Chronic Illness Therapy-Palliative Care-14 (FACIT-PAL-14). Articles that discussed questionnaire length, intended use, scoring procedure, and validation were included. The 7-item FACT-G7 is the shortest instrument, whereas the EORTC QLQ-C15-PAL and the FACIT-PAL-14 contain 14 and 15 items, respectively. All three questionnaires have similar recall period, item organization, and subscale components. Designed as core questionnaires, all three maintain content and concurrent validity of their unabridged original questionnaires. Both the EORTC QLQ-C15-PAL and the FACT-G7 demonstrate good internal consistency and reliability, with Cronbach's α ≥0.7 deemed acceptable. The developmental study for the FACIT-PAL-14 was published in 2013 and subsequent validation studies are not yet available. The EORTC QLQ-C15-PAL and the FACT-G7 were found to be reliable and appropriate for assessing health-related QoL issues-the former for palliative cancer patients and the latter for advanced cancer patients receiving chemotherapy. Conceptually, the FACIT-PAL-14 holds promise to cover social and emotional support issues that are not completely addressed by the other two questionnaires; however, further validation is needed.

  20. Correction of rabbit model with mandibular ramus shortening by distraction osteogenesis at condylar neck.

    Meng, Qinggong; Yang, Xuewen; Long, Xing; Li, Jian; Cai, Hengxing

    2012-04-01

    The rabbit model has been established to mimic the effect of temporomandibular joint (TMJ) arthroplasty of ankylosis, and distraction at the level of the condylar neck is used to elongate the ascending ramus. The histomorphologic changes of TMJ and distraction gap were investigated. The unilateral condyles and articular discs were extirpated, and the experimental mandibular rami were shortened by 5 mm. An embedded distracter was used to restore the height of the mandibular ramus by unilateral condylar neck distraction (0.8 mm daily for 7 days). A total of 12 adult white rabbits were used, 8 in the experimental group and 4 in the control group. Of the 8 rabbits in the experimental group, 4 each were killed at 4 and 8 weeks after completion of distraction. The TMJ and distracted calluses were harvested and processed for radiographic and histologic examination. An open bite was seen in all rabbits postoperatively that had diminished at the end of distraction. The newly formed condyles radiologically showed remodeling, flattening, and sclerosis. The bony transport disc had gradually remodeled to a new condyle that was similar to the original condyle in appearance and structure. The surface of the transport disc was covered with a fibrous tissue. Moreover, the bony regeneration was perfect in the distraction gap. These results suggest that distraction osteogenesis at the condylar neck using the traditional preauricular approach of TMJ surgery, without the additional incision, can be performed concurrently with arthroplasty of TMJ ankylosis at the same region. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.