WorldWideScience

Sample records for line gas ionisation

  1. Ionised gas kinematics in bipolar H II regions

    Science.gov (United States)

    Dalgleish, Hannah S.; Longmore, Steven N.; Peters, Thomas; Henshaw, Jonathan D.; Veitch-Michaelis, Joshua L.; Urquhart, James S.

    2018-05-01

    Stellar feedback plays a fundamental role in shaping the evolution of galaxies. Here we explore the use of ionised gas kinematics in young, bipolar H II regions as a probe of early feedback in these star-forming environments. We have undertaken a multi-wavelength study of a young, bipolar H II region in the Galactic disc, G316.81-0.06, which lies at the centre of a massive (˜103 M⊙) infrared-dark cloud filament. It is still accreting molecular gas as well as driving a ˜0.2 pc ionised gas outflow perpendicular to the filament. Intriguingly, we observe a large velocity gradient (47.81 ± 3.21 km s-1 pc-1) across the ionised gas in a direction perpendicular to the outflow. This kinematic signature of the ionised gas shows a reasonable correspondence with the simulations of young H II regions. Based on a qualitative comparison between our observations and these simulations, we put forward a possible explanation for the velocity gradients observed in G316.81-0.06. If the velocity gradient perpendicular to the outflow is caused by rotation of the ionised gas, then we infer that this rotation is a direct result of the initial net angular momentum in the natal molecular cloud. If this explanation is correct, this kinematic signature should be common in other young (bipolar) H II regions. We suggest that further quantitative analysis of the ionised gas kinematics of young H II regions, combined with additional simulations, should improve our understanding of feedback at these early stages.

  2. Ionised gas structure of 100 kpc in an over-dense region of the galaxy group COSMOS-Gr30 at z 0.7

    Science.gov (United States)

    Epinat, B.; Contini, T.; Finley, H.; Boogaard, L. A.; Guérou, A.; Brinchmann, J.; Carton, D.; Michel-Dansac, L.; Bacon, R.; Cantalupo, S.; Carollo, M.; Hamer, S.; Kollatschny, W.; Krajnović, D.; Marino, R. A.; Richard, J.; Soucail, G.; Weilbacher, P. M.; Wisotzki, L.

    2018-01-01

    We report the discovery of a 104 kpc2 gaseous structure detected in [O II]λλ3727, 3729 in an over-dense region of the COSMOS-Gr30 galaxy group at z 0.725 with deep MUSE Guaranteed Time Observations. We estimate the total amount of diffuse ionised gas to be of the order of ( 5 ± 3) × 1010 M⊙ and explore its physical properties to understand its origin and the source(s) of the ionisation. The MUSE data allow the identification of a dozen group members that are embedded in this structure through emission and absorption lines. We extracted spectra from small apertures defined for both the diffuse ionised gas and the galaxies. We investigated the kinematics and ionisation properties of the various galaxies and extended gas regions through line diagnostics (R23, O32, and [O III]/Hβ) that are available within the MUSE wavelength range. We compared these diagnostics to photo-ionisation models and shock models. The structure is divided into two kinematically distinct sub-structures. The most extended sub-structure of ionised gas is likely rotating around a massive galaxy and displays filamentary patterns that link some galaxies. The second sub-structure links another massive galaxy that hosts an active galactic nucleus (AGN) to a low-mass galaxy, but it also extends orthogonally to the AGN host disc over 35 kpc. This extent is likely ionised by the AGN itself. The location of small diffuse regions in the R23 vs. O32 diagram is compatible with photo-ionisation. However, the location of three of these regions in this diagram (low O32, high R23) can also be explained by shocks, which is supported by their high velocity dispersions. One edge-on galaxy shares the same properties and may be a source of shocks. Regardless of the hypothesis, the extended gas seems to be non-primordial. We favour a scenario where the gas has been extracted from galaxies by tidal forces and AGN triggered by interactions between at least the two sub-structures. Based on observations made with

  3. The ionisation equation in a relativistic gas

    International Nuclear Information System (INIS)

    Kichenassamy, S.; Krikorian, R.A.

    1983-01-01

    By deriving the relativistic form of the ionisation equation for a perfect gas it is shown that the usual Saha equation is valid to 3% for temperatures below one hundred million Kelvin. Beyond 10 9 K, the regular Saha equation is seriously incorrect and a relativistic distribution function for electrons must be taken into account. Approximate forms are derived when only the electrons are relativistic (appropriate up to 10 12 K) and also for the ultrarelativistic case (temperatures greater than 10 15 K). (author)

  4. On the critical current of ionisation waves in gas discharges

    International Nuclear Information System (INIS)

    Sato, M.

    1982-01-01

    Measurement methods for determining the critical current of ionisation waves in gas discharge tubes are examined in detail. The conventional visual method which finds the current at which the waves disappear is erroneous since the criterion, 'observable', depends on the observing conditions. In the rigorous method it is defined as a current at which the linear growth rate of waves is zero. For the measured upper critical (Pupp) current of argon gas, close agreement is found between the results of other workers and those of the present author over a wide range of pressure-radius product 0.3 approximately equal to 60 Torr cm. (author)

  5. The ionisation loss of relativistic charged particles in thin gas samples and its use for particle identification. I

    International Nuclear Information System (INIS)

    Cobb, J.H.; Allison, W.W.M.; Bunch, J.N.

    1976-01-01

    A brief review shows a significant discrepancy between available data and theoretical predictions on the ionisation loss of charged particles in thin gas-filled proportional counters. The discrepancy related both to the increase of the most probable loss at relativistic velocities (relativistic rise) and to the spectrum of such losses at a given velocity (the Landau distribution). The origin of this relativistic rise is discussed in simple terms and related to the phenomena of transition radiation and Cherenkov radiation. It is shown that the failure of the prediction is due to the small number of ionising collisions in a gas. This problem is overcome by using a Monte Carlo method rather than a continuous integral over the spectrum of single collision processes. A specific mode of the atomic form factors is used with a modified Born approximation to yield the differential cross sections needed for the calculation. The new predictions give improved agreement with experiment and are used to investigate the problem of identifying particles of known momenta in the relativistic region. It is shown that by measuring the ionisation loss of each particle several hundred times over 5m or more, kaon, pion and proton separation with good confidence level may be achieved. Many gases are considered and a comparison is made. The results are also compared with the velocity resolution achievable by measuring primary ionisation. (Auth.)

  6. An investigation of the matrix sensitivity of refinery gas analysis using gas chromatography with flame ionisation detection.

    Science.gov (United States)

    Ferracci, Valerio; Brown, Andrew S; Harris, Peter M; Brown, Richard J C

    2015-02-27

    The response of a flame ionisation detector (FID) on a gas chromatograph to methane, ethane, propane, i-butane and n-butane in a series of multi-component refinery gas standards was investigated to assess the matrix sensitivity of the instrument. High-accuracy synthetic gas standards, traceable to the International System of Units, were used to minimise uncertainties. The instrument response exhibited a small dependence on the component amount fraction: this behaviour, consistent with that of another FID, was thoroughly characterised over a wide range of component amount fractions and was shown to introduce a negligible bias in the analysis of refinery gas samples, provided a suitable reference standard is employed. No significant effects of the molar volume, density and viscosity of the gas mixtures on the instrument response were observed, indicating that the FID is suitable for the analysis of refinery gas mixtures over a wide range of component amount fractions provided that appropriate drift-correction procedures are employed. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. A gas ionisation Direct-STIM detector for MeV ion microscopy

    International Nuclear Information System (INIS)

    Norarat, Rattanaporn; Guibert, Edouard; Jeanneret, Patrick; Dellea, Mario; Jenni, Josef; Roux, Adrien; Stoppini, Luc; Whitlow, Harry J.

    2015-01-01

    Direct-Scanning Transmission Ion Microscopy (Direct-STIM) is a powerful technique that yields structural information in sub-cellular whole cell imaging. Usually, a Si p-i-n diode is used in Direct-STIM measurements as a detector. In order to overcome the detrimental effects of radiation damage which appears as a broadening in the energy resolution, we have developed a gas ionisation detector for use with a focused ion beam. The design is based on the ETH Frisch grid-less off-axis Geiger–Müller geometry. It is developed for use in a MeV ion microscope with a standard Oxford Microbeams triplet lens and scanning system. The design has a large available solid angle for other detectors (e.g. proton induced fluorescence). Here we report the performance for imaging ReNcells VM with μm resolution where energy resolutions of <24 keV fwhm could be achieved for 1 MeV protons using isobutane gas

  8. Looking into individual coffee beans during the roasting process: direct micro-probe sampling on-line photo-ionisation mass spectrometric analysis of coffee roasting gases.

    Science.gov (United States)

    Hertz-Schünemann, Romy; Streibel, Thorsten; Ehlert, Sven; Zimmermann, Ralf

    2013-09-01

    A micro-probe (μ-probe) gas sampling device for on-line analysis of gases evolving in confined, small objects by single-photon ionisation time-of-flight mass spectrometry (SPI-TOFMS) was developed. The technique is applied for the first time in a feasibility study to record the formation of volatile and flavour compounds during the roasting process within (inside) or in the direct vicinity (outside) of individual coffee beans. A real-time on-line analysis of evolving volatile and semi-volatile organic compounds (VOC and SVOC) as they are formed under the mild pyrolytic conditions of the roasting process was performed. The soft-ionisation mass spectra depict a molecular ion signature, which is well corresponding with the existing knowledge of coffee roasting and evolving compounds. Additionally, thereby it is possible to discriminate between Coffea arabica (Arabica) and Coffea canephora (Robusta). The recognized differences in the roasting gas profiles reflect the differences in the precursor composition of the coffee cultivars very well. Furthermore, a well-known set of marker compounds for Arabica and Robusta, namely the lipids kahweol and cafestol (detected in their dehydrated form at m/z 296 and m/z 298, respectively) were observed. If the variation in time of different compounds is observed, distinctly different evolution behaviours were detected. Here, phenol (m/z 94) and caffeine (m/z 194) are exemplary chosen, whereas phenol shows very sharp emission peaks, caffeine do not have this highly transient behaviour. Finally, the changes of the chemical signature as a function of the roasting time, the influence of sampling position (inside, outside) and cultivar (Arabica, Robusta) is investigated by multivariate statistics (PCA). In summary, this pilot study demonstrates the high potential of the measurement technique to enhance the fundamental knowledge of the formation processes of volatile and semi-volatile flavour compounds inside the individual coffee bean.

  9. Dosimetry with tissue-equivalent ionisation chambers in fast neutron fields for biomedical applications

    International Nuclear Information System (INIS)

    Zoetelief, J.; Broerse, J.J.

    1983-01-01

    The use of calibrated tissue-equivalent (TE) ionisation chambers is commonly considered to be the most practical method for total absorbed dose determinations in mixed neutron-photon fields for biomedical applications. The total absorbed dose can be derived from the charge produced within the cavity of an ionisation chamber employing a number of physical parameters. To arrive at the charge produced in the cavity several correction factors have to be introduced which are related to the operational characteristics of the chambers. Information on the operational characteristics of four TE ionisation chambers is presented in relation to ion collection, density and composition of gas in the cavity, wall thickness and effective point of measurement. In addition, some recent results from an ionisation chamber operated at high gas pressures are presented. The total absorbed doses derived from TE ionisation chambers show agreement within the uncertainty limits with results from other independent dosimetry methods, i.e., differential fluence measurements and a TE calorimeter. Conscientious experimentation and a common data base can provide dosimetry results with TE ionisation chambers with variations of less than +-2%. (author)

  10. Ionisation detectors as monitors of toxic compounds in air

    International Nuclear Information System (INIS)

    Leonhardt, J.W.

    1994-01-01

    Beta particles cause ionisation in gas mixtures. The ions produced provide information on the concentration and identity of trace compounds in ambient air. Modern ionisation detectors use ion mobilities to monitor toxic compounds. Chemical solvent, phosphororganic compounds, PCB and many other toxins can be detected using ion mobility detectors (IMD) in the ppb range or lower. Ion mobility detectors have large potential in industry and research because of their sensitivity, specificity, fast response and relatively low cost. Portable devices and fixed installations are possible. The paper discusses the following topics: (1) ionisation sources in IMD: 63 Ni, 3 H, photoionization and corona discharge, (2) basic principles of ion production, (3) ion collection in IMD, (4) design, gas supply, automatic identification and quantification of IMD data, and (5) selected applications. Advantages and problems with this new type of nuclear analytical instrument are also discussed. (author). 2 refs., 9 figs., 3 tabs

  11. The use of detectors based on ionisation recombination in radiation protection

    International Nuclear Information System (INIS)

    Sullivan, A.H.

    1984-01-01

    Intitial recombination of ionisation in a gas depends on the ionisation density and hence on the linear energy transfer along the tracks of charged particles. This effect can be used as a basis for instruments that respond to different types of ionising radiation approximately in the way required by the quality factor-linear energy transfer relation recommended by the ICRP for use in radiation protection. Empirical instruments based on ionisation recombination that have been used for radiation protection measurements are reviewed, and relations are derived from recombination theory that show that the response of such detectors can be readily predicted. The usefulness of recombination instruments in radiation protection is discussed and their advantages and limitations assessed. It is shown that their main application will be as reference instruments against which other detectors can be calibrated. As an extension to using recombination detectors as reference instruments, the feasibility of specifying radiation quality in terms of ionisation recombination is investigated. (author)

  12. Sensitivity of gaseous xenon ionisation chambers (1961); Sensibilite des chambres d'ionisation a xenon gazeux (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Schuhl, C [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    It seems advantageous to fill an ionization chamber with xenon gas when this chamber is used for measuring a low intensity and high energy electron or positron beam, or monitoring a gamma beam. In the study of 5 to 50 MeV electrons, xenon allows for the ionization chamber yield, an improvement of a factor 4,5. (author) [French] Il apparait interessant d'utiliser du xenon comme gaz dans une chambre d'ionisation destinee a mesurer un faisceau d'electrons ou de positons de faible intensite et de grande energie ou pour monitorer un faisceau de gamma. Dans les etudes des electrons de 5 a 50 MeV, le xenon permet de gagner un facteur 4,5 sur l'air pour la sensibilite d'une chambre d'ionisation. (auteur)

  13. AGN feedback on molecular gas reservoirs in quasars at z 2.4

    Science.gov (United States)

    Carniani, S.; Marconi, A.; Maiolino, R.; Feruglio, C.; Brusa, M.; Cresci, G.; Cano-Díaz, M.; Cicone, C.; Balmaverde, B.; Fiore, F.; Ferrara, A.; Gallerani, S.; La Franca, F.; Mainieri, V.; Mannucci, F.; Netzer, H.; Piconcelli, E.; Sani, E.; Schneider, R.; Shemmer, O.; Testi, L.

    2017-09-01

    We present new ALMA observations aimed at mapping molecular gas reservoirs through the CO(3-2) transition in three quasars at z ≃ 2.4, LBQS 0109+0213, 2QZ J002830.4-281706, and [HB89] 0329-385. Previous [Oiii]λ5007 observations of these quasars showed evidence for ionised outflows quenching star formation in their host galaxies. Systemic CO(3-2) emission has been detected only in one quasar, LBQS 0109+0213, where the CO(3-2) emission is spatially anti-correlated with the ionised outflow, suggesting that most of the molecular gas may have been dispersed or heated in the region swept by the outflow. In all three sources, including the one detected in CO, our constraints on the molecular gas mass indicate a significantly reduced reservoir compared to main-sequence galaxies at the same redshift, supporting a negative feedback scenario. In the quasar 2QZ J002830.4-281706, we tentatively detect an emission line blob blue-shifted by v - 2000 km s-1 with respect to the galaxy systemic velocity and spatially offset by 0.2'' (1.7 kpc) with respect to the ALMA continuum peak. Interestingly, such emission feature is coincident in both velocity and space with the ionised outflow as seen in [Oiii]λ5007. This tentative detection must be confirmed with deeper observations but, if real, it could represent the molecular counterpart of the ionised gas outflow driven by the Active Galactic Nucleus (AGN). Finally, in all ALMA maps we detect the presence of serendipitous line emitters within a projected distance 160 kpc from the quasars. By identifying these features with the CO(3-2) transition, we find that the serendipitous line emitters would be located within | Δv | < 500 km s-1 from the quasars, hence suggesting an overdensity of galaxies in two out of three quasars.

  14. Investigation of gas discharge ion sources for on-line mass separation

    International Nuclear Information System (INIS)

    Kirchner, R.

    1976-03-01

    The development of efficient gas discharge ion sources with axial beam extraction for on-line mass separation is described. The aim of the investigation was to increase the ion source temperature, the lifetime and the ionisation yield in comparison to present low-pressure are discharge ion sources and to reduce the ion current density from usually 1 to 100 mA/cm 3 . In all ion sources the pressure range below the minimal ignition pressure of the arc discharge was investigated. As a result an ion source was developed which works at small changes in geometry and in electric device of a Nielsen source with high ionization yield (up to 50% for xenon) stabil and without ignition difficulties up to 10 -5 Torr. At a typical pressure of 3 x 10 -5 Torr ion current and ion current density are about 1 μA and 0.1 mA/cm 3 respectively besides high yield and a great emission aperture (diameter 1.2 mm). (orig.) [de

  15. Atmospheric ionisation in Snowdonia

    Energy Technology Data Exchange (ETDEWEB)

    Aplin, K L [Department of Physics, University of Oxford, Denys Wilkinson Building, Keble Road, Oxford OX1 3RH UK (United Kingdom); Williams, J H, E-mail: k.aplin1@physics.ox.ac.uk [Envirodata-Eyri, Bryn Goleu, Penmaen Park, Llanfairfechan, Gwynedd LL33 0RL (United Kingdom)

    2011-06-23

    Atmospheric ionisation from natural radioactivity and cosmic rays has been measured at several sites in Snowdonia from 2005-present. The motivation for this project was a combination of public engagement with science, and research into the effects of ionisation on climate. A four-component atmospheric radiometer instrument is co-located with the ionisation detectors and the data is remotely logged and displayed on the Web. Atmospheric ionisation from natural radioactivity varies with local geology, and the cosmic ray ionisation component is modulated by solar activity and altitude. Variations due to all these effects have been identified and are described.

  16. Measurement of the electronic density of ionised media by hyper frequency methods; Mesure de la densite electronique des milieux ionises par des methodes hyperfrequences

    Energy Technology Data Exchange (ETDEWEB)

    Consoli, T [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1960-07-01

    Within the limits of the I.N.S.T.N. courses on plasmas, this analytical study summarizes the articles quoted in the references on hyper-frequency techniques for the measurement of electronic density of an ionised gas. It is neither exhaustive nor complete and further details may be obtained by referring to the works mentioned. The first part, devoted to the theoretical side, concert the propagation of electromagnetic waves ionised media and the excitation of stationary raves in electromagnetic cavities. The second part deals with the measurement techniques themselves. It includes those techniques which hare become classic, and also more recent ones being developed in various laboratories and in the Service of Applied Physics at Saclay. (author) [French] Dans le cadre des cours sur les plasmas a l'l.N.S.T. cette etude d'analyse resume les articles cites en bibliographie sur les techniques hyperfrequences pour la mesure de la densite electronique d'un gas ionise. Elle n'est ni exhaustive, ni complete. Pour plus de details on voudra bien se rapporter aux travaux mentionnes. La premiere partie consacree a des rappels theoriques, concerne la propagation des ondes electromagnetiques dans les milieux ionises et sur l'excitation d'ondes stationnaires dans les cavites electromagnetiques. La seconde se rapporte aux techniques de mesures proprement dites. On a fait figurer dans cette partie des techniques devenues classiques et celles plus recentes en cours d'etudes dans divers laboratoires et au Service de Physique Appliquee a SACLAY. (auteur)

  17. Critical ionisation velocity effects in astrophysical plasmas

    International Nuclear Information System (INIS)

    Raadu, M.A.

    1979-08-01

    Critical ionisation velocity effects are relevant to astrophysical situations where neutral gas moves through a magnetised plasma. The experimental significance of the critical velocity is well established and the physical basis is now becoming clear. The underlying mechanism depends on the combined effects of electron impact ionisation and electron energisation by collective plasma interactions. For low density plasmas a theory based on a circular process involving electron heating through a modified two stream instability has been developed. Several applications of critical velocity effects to astrophysical plasmas have been discussed in the literature. The importance of the effect in any particular case may be determined from a detailed consideration of energy and momentum balance, using appropriate atomic rate coefficients and taking full account of collective plasma processes. (Auth.)

  18. Rapid and simultaneous determination of polychlorinated biphenyls and their main metabolites (hydroxylated and methyl sulfonyl) by gas chromatography coupled to mass spectrometry: Comparison of different ionisation modes

    International Nuclear Information System (INIS)

    Castro-Puyana, M.; Herrero, L.; González, M.J.; Gómara, B.

    2013-01-01

    Graphical abstract: -- Highlights: •Simultaneous determination of PCB, OH-PCBs and MeSO 2 -PCBs in a single GC–MS run. •Two different ionisation modes (EI and ECNI) are studied and compared. •The analytical characterisation of both methods is satisfactory. •Better LODs are achieved using ECNI-MS as ionisation mode. •The developed methodology is successfully applied to fish liver oil. -- Abstract: Instrumental methods based on gas chromatography coupled to mass spectrometry (GC–MS) have been developed and compared using two different MS ionisation modes, electron impact (EI) and electron capture negative ionisation (ECNI), for the fast, quantitative and simultaneous determination of polychlorinated biphenyls (PCBs) and their main metabolites (hydroxylated PCBs, OH-PCBs, and methyl sulfone PCBs, MeSO 2 -PCBs). Parameters affecting chromatographic separation and MS detection were evaluated in order to achieve the highest selectivity and sensitivity for both operation modes. The analytical characteristics of the developed methods were studied and compared in terms of linear range, limits of detection (LODs), limits of quantification (LOQs), and instrumental precision (repeatability and intermediate precision). Both ionisation methods showed similar precision, being relative standard deviations (RSD, %) lower than 9% and 14% for repeatability and intermediate precision, respectively. However, better LODs (from 0.01 to 0.14 pg injected for the three families of congeners studied) were achieved using ECNI-MS as ionisation mode. The suitability of the developed method was demonstrated through their application to fish liver oil samples

  19. European Code against Cancer 4th Edition: Ionising and non-ionising radiation and cancer

    NARCIS (Netherlands)

    N. McColl (Neil); A. Auvinen (Anssi); A. Kesminiene (Ausrele); C. Espina (Carolina); F. Erdmann (Friederike); E. de Vries (Esther); R. Greinert (Rüdiger); J. Harrison (John); J. Schüz (Joachim)

    2015-01-01

    textabstractIonising radiation can transfer sufficient energy to ionise molecules, and this can lead to chemical changes, including DNA damage in cells. Key evidence for the carcinogenicity of ionising radiation comes from: follow-up studies of the survivors of the atomic bombings in Japan; other

  20. Determination of the ionisation potential of certain hydrocarbons in the liquid phase

    International Nuclear Information System (INIS)

    Casanovas, J.; Grob, R.; Brunet, G.; Sabattier, R.; Guelfucci, J.P.; Blanc, D.

    1978-01-01

    The first results obtained are presented on the determination of the ionisation potential of four alkanes (n-hexane, n-pentane, cyclopentane and trimethyl-2,2,4 pentane) in the liquid phase. In the gaseous phase, the ionisation potential values of these hydrocarbons are respectively 10.18 eV for n-hexane, 10.35 eV for n-pentane, 10.53 eV for cyclopentane and 9.86 eV for trimethyl-2,2,4 pentane. Consequently rare gas resonance lamps (krypton and Xenon) were made, sealed and excited by an ultra-high frequency wave, which emit photons in the energy field concerned, i.e. from 8.5 eV to 11eV. The energy of the photons emitted by these lamps is respectively 8.44 eV (100%) and 9.57 eV (2%) for xenon and 10.03 eV (100%) and 10.64 eV (5%) for krypton. From the extent of the induced ionisation currents and particularly the value of the ratio of the currents induced by the photons of the krypton and xenon lamps, a minimum value of the ionisation potential drop can be deduced compared with the gas phase of 0.61 eV for n-hexane, 0.78 eV for n-pentane, 0.96 eV for cyclopentane and a maximum value of 1.42 eV for trimethyl-2,2,4 pentane [fr

  1. Attenuation of acoustic waves through reflections at the plasma neutral gas interfaces: weakly ionised case

    International Nuclear Information System (INIS)

    Ghosal, S.K.; Sen, S.N.

    1977-01-01

    The problem of transmission of sonic waves through a weakly ionised plasma bounded in each side by a neutral gas medium has been treated by assuming the plasma to be a mixture of two intermingled fluids viz., neutral particle fluid and ion fluid in equilibrium. From a hydrodynamic analysis the wave equation for 'p', the macroscopic pressure perturbation has been obtained and it is shown that two independent wave motions, one due to the neutral particles and the other due to ions are propagated through the plasma with two different phase velocities. Assuming the usual boundary conditions at the interface, the amplitude of the transmitted wave has been calculated in case of weakly ionized plasma; the theory can be utilized for the determination of electron temperature from the measured value of attenuation if the percentage of ionization and collision cross section can be obtained independently. (author)

  2. Russians and Ukrainians plan new gas line

    International Nuclear Information System (INIS)

    TREND

    2003-01-01

    Paper deals with the building of new gas line between Russia and the Ukraine. In September 2003 Gazprom and Naftohaz Ukraine signed protocol about conditions of Russian gas transit through Ukrainian area for 2004. There is guaranteed quantity of transported gas on the level of 127,8 billions cubic meters by Russian side, 110 billions of it should next lead to Europe. Treaty refills long-term contract between Naftohaz and Gazprom about gas transit through Ukraine for period 2003-2013. Both countries and its companies plan to accept particular capital decision about building of new gas line Novopskov-Uzgorod till end of this year, which will be parallel with gas line Soyuz. It will allow to enlarge transportation system capacity by 28 billion cubic meters. Construction of about 1600 km long ducting system will require 1.6 billion USD by annual capacity about 15 billion cubic meters. If capacity would be doubled by construction of another compressor stations, capital expenses rise to 2.2 billions USD. It can be completely built in 7 years. Its linear part with one compressor can be already built in 3 years. Slovensky Plynarensky Podnik (SPP) would certainly have advantages from possible realisation of new gas line and from consequential transit increase. (Author)

  3. The work of the ILO in the field of protection of workers against ionising and non-ionising radiations

    International Nuclear Information System (INIS)

    Coppee, G.H.

    1980-01-01

    A chronological account since 1934 of the activities of the International Labour Organization (ILO) in the protection of workers against risks due to ionising and non-ionising radiations is given. Several ILO publication on safety standards and codes of practice for protection against mainly ionising radiation in various occupational situations are indicated. A more intensive study by the ILO on the protection of workers against non-ionising radiation was proposed for 1980-81. (UK)

  4. Control and calculation of the titanium sublimation pumping speed and re-ionisation in the MAST neutral beam injectors

    International Nuclear Information System (INIS)

    McAdams, R.

    2015-01-01

    Highlights: • The titanium sublimation pumps for the MAST neutral beam injectors are described. • Evaporation regimes are established to give constant pumping speed for the titanium sublimation pumps. • The MCNP code is used to calculate the pumping speeds and gas profiles in the neutral beam injectors. • The gas profiles are then used to calculate the level of re-ionisation in the beamline. - Abstract: A high pumping speed is required in neutral beam injectors to minimise re-ionisation of the neutral beams. The neutral beam injectors on MAST use titanium sublimation pumps. These pumps do not have a constant pumping speed; their pumping speed depends on the gettering surface history and on both the integrated and applied gas load. In this paper we describe a method of maintaining a constant pumping speed, through different evaporation schemes, specifically suitable for operations of the MAST neutral beam injector beamlines for both short and relatively long beam pulses by measurement of the pressure in the beamline. In addition the MCNP code is then used to calculate the pumping speed and gas profile in the beamline by adjusting the input pumping speed to match the measured pressure. This allows the resulting gas profile to be used for calculation of the re-ionisation levels and an example is given

  5. European Code against Cancer 4th Edition: Ionising and non-ionising radiation and cancer.

    Science.gov (United States)

    McColl, Neil; Auvinen, Anssi; Kesminiene, Ausrele; Espina, Carolina; Erdmann, Friederike; de Vries, Esther; Greinert, Rüdiger; Harrison, John; Schüz, Joachim

    2015-12-01

    Ionising radiation can transfer sufficient energy to ionise molecules, and this can lead to chemical changes, including DNA damage in cells. Key evidence for the carcinogenicity of ionising radiation comes from: follow-up studies of the survivors of the atomic bombings in Japan; other epidemiological studies of groups that have been exposed to radiation from medical, occupational or environmental sources; experimental animal studies; and studies of cellular responses to radiation. Considering exposure to environmental ionising radiation, inhalation of naturally occurring radon is the major source of radiation in the population - in doses orders of magnitude higher than those from nuclear power production or nuclear fallout. Indoor exposure to radon and its decay products is an important cause of lung cancer; radon may cause approximately one in ten lung cancers in Europe. Exposures to radon in buildings can be reduced via a three-step process of identifying those with potentially elevated radon levels, measuring radon levels, and reducing exposure by installation of remediation systems. In the 4th Edition of the European Code against Cancer it is therefore recommended to: "Find out if you are exposed to radiation from naturally high radon levels in your home. Take action to reduce high radon levels". Non-ionising types of radiation (those with insufficient energy to ionise molecules) - including extremely low-frequency electric and magnetic fields as well as radiofrequency electromagnetic fields - are not an established cause of cancer and are therefore not addressed in the recommendations to reduce cancer risk. Copyright © 2015 International Agency for Research on Cancer. Published by Elsevier Ltd. All rights reserved.

  6. Immunosuppression by non-ionising and ionising radiation - are there similarities?

    International Nuclear Information System (INIS)

    Reeves, V.

    2003-01-01

    Solar UV radiation, the ubiqitous environmental non-ionising radiation, initiates its immunomodulating effects almost entirely in the skin. In direct contrast, ionising radiation penetrates much more efficiently, and has a multitude of internal targets throughout the body. As a consequence, the mechanisms underlying UV-induced immunosuppression have been more readily characterised, whereas surprisingly little is known about immunosuppression resulting from ionising radiation. Photoimmunological studies in mice during the past 20-30 years have established the action spectrum for UV-induced immunosuppression, implicating the UVB waveband, 290-320 nm. Controversy rages over the immunosuppressive potential of the UVA waveband, 320-400 nm, but we demonstrate that environmentally relevant doses of UVA not only are immunologically innocuous, but provide protection against UVB-immunosuppression. Increasingly larger UVA exposures increasingly immunosuppress mice. The UVA immunoprotective effect is strongly dependent on the induction of a cutaneous redox-regulated enzyme, haem oxygenase (heat shock protein 32) that is known to protect cells from oxidative stress, and it is consistent that a number of exogenous antioxidants (vitamin E, vitamin C, green tea polyphenols, isoflavones) can protect effectively from photoimmuno-suppression. Thus the UV-immunosuppressed state is promoted by oxidative damage and depletion of endogenous antioxidant molecules. It is also associated with cutaneous cytokine derangements, such that Th-2 cytokines (IL-4, IL-10) are increased at the expense of Th-1 cytokines (IFN-gamma, IL-12), and with histamine and inflammatory prostaglandin activity. In contrast, immunoprotective UVA irradiation protects the cutaneous cytokine array, inhibits IL-10 upregulation and increases IFN-gamma and IL-12 expression. On the other hand, while ionising radiation is known to cause immunosuppression, large doses target the bone marrow and haemopoiesis lethally and

  7. Acid-yield measurements of the gas-phase ozonolysis of ethene as a function of humidity using Chemical Ionisation Mass Spectrometry (CIMS

    Directory of Open Access Journals (Sweden)

    K. E. Leather

    2012-01-01

    Full Text Available Gas-phase ethene ozonolysis experiments were conducted at room temperature to determine formic acid yields as a function of relative humidity (RH using the integrated EXTreme RAnge chamber-Chemical Ionisation Mass Spectrometry technique, employing a CH3I ionisation scheme. RHs studied were <1, 11, 21, 27, 30 % and formic acid yields of (0.07±0.01 and (0.41±0.07 were determined at <1 % RH and 30 % RH respectively, showing a strong water dependence. It has been possible to estimate the ratio of the rate coefficient for the reaction of the Criegee biradical, CH2OO with water compared with decomposition. This analysis suggests that the rate of reaction with water ranges between 1×10−12–1×10−15 cm3 molecule−1 s−1 and will therefore dominate its loss with respect to bimolecular processes in the atmosphere. Global model integrations suggest that this reaction between CH2OO and water may dominate the production of HC(OOH in the atmosphere.

  8. Complex systems of biological interest stability under ionising radiations

    International Nuclear Information System (INIS)

    Maclot, Sylvain

    2014-01-01

    This PhD work presents the study of stability of molecular systems of biological interest in the gas phase after interaction with ionising radiations. The use of ionising radiation can probe the physical chemistry of complex systems at the molecular scale and thus consider their intrinsic properties. Beyond the fundamental aspect, this work is part of the overall understanding of radiation effects on living organisms and in particular the use of ionizing radiation in radiotherapy. Specifically, this study focused on the use of low-energy multiply charged ions (tens of keV) provided by the GANIL (Caen), which includes most of the experiments presented. In addition, experiments using VUV photons were also conducted at synchrotron ELETTRA (Trieste, Italy). The bio-molecular systems studied are amino acids and nucleic acid constituents. Using an experimental crossed beams device allows interaction between biomolecules and ionising radiation leads mainly to the ionization and fragmentation of the system. The study of its relaxation dynamics is by time-of-flight mass spectrometry coupled to a coincidences measurements method. It is shown that an approach combining experiment and theory allows a detailed study of the fragmentation dynamics of complex systems. The results indicate that fragmentation is generally governed by the Coulomb repulsion but the intramolecular rearrangements involve specific relaxation mechanisms. (author) [fr

  9. "Soft"or "hard" ionisation? Investigation of metastable gas temperature effect on direct analysis in real-time analysis of Voriconazole.

    Science.gov (United States)

    Lapthorn, Cris; Pullen, Frank

    2009-01-01

    The performance of the direct analysis in real-time (DART) technique was evaluated across a range of metastable gas temperatures for a pharmaceutical compound, Voriconazole, in order to investigate the effect of metastable gas temperature on molecular ion intensity and fragmentation. The DART source has been used to analyse a range of analytes and from a range of matrices including drugs in solid tablet form and preparations, active ingredients in ointment, naturally occurring plant alkaloids, flavours and fragrances, from thin layer chromatography (TLC) plates, melting point tubes and biological matrices including hair, urine and blood. The advantages of this technique include rapid analysis time (as little as 5 s), a reduction in sample preparation requirements, elimination of mobile phase requirement and analysis of samples not typically amenable to atmospheric pressure ionisation (API) techniques. This technology has therefore been proposed as an everyday tool for identification of components in crude organic reaction mixtures.

  10. On-line optimal control improves gas processing

    International Nuclear Information System (INIS)

    Berkowitz, P.N.; Papadopoulos, M.N.

    1992-01-01

    This paper reports that the authors' companies jointly funded the first phase of a gas processing liquids optimization project that has the specific purposes to: Improve the return of processing natural gas liquids, Develop sets of control algorithms, Make available a low-cost solution suitable for small to medium-sized gas processing plants, Test and demonstrate the feasibility of line control. The ARCO Willard CO 2 gas recovery processing plant was chosen as the initial test site to demonstrate the application of multivariable on-line optimal control. One objective of this project is to support an R ampersand D effort to provide a standardized solution to the various types of gas processing plants in the U.S. Processes involved in these gas plants include cryogenic separations, demethanization, lean oil absorption, fractionation and gas treating. Next, the proposed solutions had to be simple yet comprehensive enough to allow an operator to maintain product specifications while operating over a wide range of gas input flow and composition. This had to be a supervisors system that remained on-line more than 95% of the time, and achieved reduced plant operating variability and improved variable cost control. It took more than a year to study various gas processes and to develop a control approach before a real application was finally exercised. An initial process for C 2 and CO 2 recoveries was chosen

  11. Doubling potential of fibroblasts from different species after ionising radiation

    International Nuclear Information System (INIS)

    Macieira-Coelho, A.; Diatloff, C.; Malaise, E.

    1976-01-01

    It is stated that whereas chicken fibroblasts invariably die after a certain number of doublings in vitro, and this fact is never altered by chemical or physical agents, mouse fibroblasts invariably acquire spontaneously an infinite growth potential. In the human species fibroblasts never acquire spontaneously the capacity to divide for ever, although they can become permanent cell lines after treatment with certain viruses. This behaviour of fibroblasts in vitro has been attributed to different nutritional requirements. Experiments are described with human and mouse fibroblasts in which it was found that the response to ionising radiation matches the relative tendencies of the fibroblasts to yield permanent cell lines. Irradiation was commenced during the phase of active proliferation. Human fibroblast cultures irradiated with 100 R stopped dividing earlier than the controls, whereas cultures irradiated with 200, 300 and 500 R had the same lifespan as the control cultures. Cultures irradiated with 400 R showed the longest survival. With mouse fibroblasts the growth curves of the irradiated cells were of the same type as in the controls, but recovery occurred earlier. The results indicated that ionising radiation accelerates a natural phenomenon; in cells with a limited growth potential (chicken) it shortens the lifespan, whereas in cells that can acquire an unlimited growth potential (mouse) it accelerates acquisition of this potential; human fibroblasts showed an intermediate response, since ionising radiation neither established the cultures as with mouse cells nor reduced the number of cells produced as with chicken fibroblasts. Possible explanations for the different behaviour of the species are offered. (U.K.)

  12. ISOLDE Off-line Gas Leak Upgrade

    CERN Document Server

    Nielsen, Kristoffer Bested

    2017-01-01

    This study investigates gas injection system of the ISOLDE Off-line separator. A quadrupole mass spectrometer is used to analysis the composition of the gas. Based on these measurements a contamination of the injected gas is found and a system upgrade is purposed. Furthermore a calibration of the leak rate of the leak valve is made.

  13. Development of sealing plug for sweep gas line

    International Nuclear Information System (INIS)

    Kikuchi, Taiji; Yamada, Hirokazu; Saitoh, Takashi; Nakamichi, Masaru; Tsuchiya, Kunihiko; Kawamura, Hiroshi

    2004-03-01

    On the irradiation capsule for neutron irradiation test of the tritium breeder, the sealing plug is necessary to prevent a leak of tritium gas when the tritium breeder is picked up from the irradiation capsule after irradiation test. However, the general valve and plug cannot apply to sealing of the sweep gas line because of the following factors, the neutron irradiation effect, limited space in the irradiation capsule, high sealing efficiency, simple method and operation for control. Therefore, the sealing plug for sweep gas line has to be developed. This paper reports the development of the sealing plug for sweep gas line and the operating procedure of the sealing plug in the irradiation capsule. (author)

  14. A Discussion about Ionising and Non-Ionising Radiation and the Critical Issue of Mobile Phones

    Science.gov (United States)

    Kontomaris, Stylianos-Vasileios; Malamou, Anna

    2018-01-01

    Electromagnetic radiation is one of the most important issues affecting peoples' lives today. The misunderstanding of students and the general population of the effects of electromagnetic radiation is a problem which must be eliminated. Thus, a discussion about ionising and non-ionising radiation focusing on the crucial issue of radiation emitted…

  15. Food ionisation. Realities and perspectives; L'ionisation alimentaire. Realites et perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Bonnet, G

    1994-06-01

    The ionisation of food is a treatment using a certain type of energy. the radiations used in the industrial treatments are limited to three sources. The gamma radiations, the x radiations and the electrons beams emitted with accelerators. The physical treatments by ionizing radiations have for aim to cleanse and to increase the conservation time of food. Now, the applications in agriculture and food industry, are still marginal. The industrial using ionisation are these ones that did not find any alternative decontamination method. The barriers are more scientific or technical or economical than a question of regulation or behaviour. (N.C.)

  16. The significance of a new correspondence principle for electromagnetic interaction in strong optical field ionisation

    International Nuclear Information System (INIS)

    Boreham, B. W.; Hora, H.

    1997-01-01

    We have recently developed a correspondence principle for electromagnetic interaction. When applied to laser interactions with electrons this correspondence principle identifies a critical laser intensity I*. This critical intensity is a transition intensity separating classical mechanical and quantum mechanical interaction regimes. In this paper we discuss the further application of I* to the interaction of bound electrons in atoms. By comparing I* with the ionisation threshold intensities as calculated from a cycle-averaged simple-atom model we conclude that I* can be usefully interpreted as a lower bound to the classical regime in studies of ionisation of gas atoms by intense laser beams

  17. Genetic effects of ionising radiation

    International Nuclear Information System (INIS)

    Saunders, P.

    1981-01-01

    The mutagenic effects of ionising radiation on germ cells with resulting genetic abnormalities in subsequent generations, are considered. Having examined a simple model to explain the interaction of ionising radiation with genetic material and discussed its limitations, the methods whereby mutations are transmitted are discussed. Methods of estimating genetic risks and the results of such studies are examined. (U.K.)

  18. Argon line broadening by neutral atoms and application to the measurement of oscillator strengths of AI resonance lines

    International Nuclear Information System (INIS)

    Vallee, O.; Ranson, P.; Chapelle, J.

    1977-01-01

    AI line broadening was studied from collisions between neutral argon atoms (3p 5 4p-3p 5 4s transitions) in a weakly ionised plasma jet (neutral atoms temperature T 0 approximately 4000K, electrons temperature Tsub(e) approximately 6000K, electronic density Nsub(e) 15 cm -3 , ionisation rate α -4 , and pressure range from 1 to 3 kg/cm 2 ). A satisfactory description of Van der Waals broadened lines is obtained by means of a Lennard-Jones potential. Measurement of line widths whose corresponding transitions occur on resonant levels, gives with relatively good accuracy the oscillator strength of the argon resonance lines [fr

  19. Food ionisation. Realities and perspectives; L'ionisation alimentaire. Realites et perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Bonnet, G

    1994-06-01

    The ionisation of food is a treatment using a certain type of energy. the radiations used in the industrial treatments are limited to three sources. The gamma radiations, the x radiations and the electrons beams emitted with accelerators. The physical treatments by ionizing radiations have for aim to cleanse and to increase the conservation time of food. Now, the applications in agriculture and food industry, are still marginal. The industrial using ionisation are these ones that did not find any alternative decontamination method. The barriers are more scientific or technical or economical than a question of regulation or behaviour. (N.C.)

  20. Fully kinetic simulations of magnetic reconnection in partially ionised gases

    Science.gov (United States)

    Innocenti, M. E.; Jiang, W.; Lapenta, G.; Markidis, S.

    2016-12-01

    Magnetic reconnection has been explored for decades as a way to convert magnetic energy into kinetic energy and heat and to accelerate particles in environments as different as the solar surface, planetary magnetospheres, the solar wind, accretion disks, laboratory plasmas. When studying reconnection via simulations, it is usually assumed that the plasma is fully ionised, as it is indeed the case in many of the above-mentioned cases. There are, however, exceptions, the most notable being the lower solar atmosphere. Small ionisation fractions are registered also in the warm neutral interstellar medium, in dense interstellar clouds, in protostellar and protoplanetary accreditation disks, in tokamak edge plasmas and in ad-hoc laboratory experiments [1]. We study here how magnetic reconnection is modified by the presence of a neutral background, i.e. when the majority of the gas is not ionised. The ionised plasma is simulated with the fully kinetic Particle-In-Cell (PIC) code iPic3D [2]. Collisions with the neutral background are introduced via a Monte Carlo plug-in. The standard Monte Carlo procedure [3] is employed to account for elastic, excitation and ionization electron-neutral collisions, as well as for elastic scattering and charge exchange ion-neutral collisions. Collisions with the background introduce resistivity in an otherwise collisionless plasma and modifications of the particle distribution functions: particles (and ions at a faster rate) tend to thermalise to the background. To pinpoint the consequences of this, we compare reconnection simulations with and without background. References [1] E E Lawrence et al. Physical review letters, 110(1):015001, 2013. [2] S Markidis et al. Mathematics and Computers in Simulation, 80(7):1509-1519, 2010. [3] K Nanbu. IEEE Transactions on plasma science, 28(3):971-990, 2000.

  1. Comparison of quantification methods for the analysis of polychlorinated alkanes using electron capture negative ionisation mass spectrometry

    NARCIS (Netherlands)

    Rusina, T.; Korytar, P.; Boer, de J.

    2011-01-01

    Four quantification methods for short-chain chlorinated paraffins (SCCPs) or polychlorinated alkanes (PCAs) using gas chromatography electron capture negative ionisation low resolution mass spectrometry (GC-ECNI-LRMS) were investigated. The method based on visual comparison of congener group

  2. 21 CFR 870.4410 - Cardiopulmonary bypass in-line blood gas sensor.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass in-line blood gas sensor... Cardiopulmonary bypass in-line blood gas sensor. (a) Identification. A cardiopulmonary bypass in-line blood gas sensor is a transducer that measures the level of gases in the blood. (b) Classification. Class II...

  3. Bioaerosol detection by aerosol TOF-mass spectrometry: Application of matrix assisted laser desorption/ionisation

    NARCIS (Netherlands)

    Wuijckhuijse, A.L. van; Stowers, M.A.; Kientz, Ch.E.; Marijnissen, J.C.M.; Scarlett, B.

    2000-01-01

    In previous publications the use of an aerosol time of flight mass spectrometer was reported for the on-line measurements of aerosols (Weiss 1997, Kievit 1995). The apparatus is capable of measuring the size as well as the chemical composition, by the use of Laser Desorption/Ionisation (LDI), of an

  4. Impact assessment of ionising radiation on wildlife

    International Nuclear Information System (INIS)

    Copplestone, D.; Bielby, S.; Jones, S.

    2001-01-01

    This R and D project was commissioned by the Environment Agency and English Nature in January 2001 to provide up-to-date information on the impacts of ionising radiation on wildlife, upon which a robust assessment approach may be developed. This approach will also feed into the European Commission funded project 'Framework for Assessment of Environmental Impact' (FASSET), due to complete in October 2003. This report describes the behaviour and transport of radionuclides in the environment, considers the impact of ionising radiation on wildlife, and makes recommendations on an approach for the impact assessment of ionising radiation on wildlife for England and Wales. The assessment approach focuses on three ecosystems representative of those considered potentially most at risk from the impact of authorised radioactive discharges, namely a coastal grassland (terrestrial ecosystem); estuarine and freshwater ecosystems. The likely scale of the impact on wildlife is also assessed in light of a preliminary analysis based on this assessment approach. The aims of the report are: to summarise the latest research on the behaviour, transfer and impact of ionising radiation effects on wildlife; an outline and review of the relevant European and national legislation which has impacts on the requirements for assessments of the impact of ionising radiation on wildlife in the UK; to consider the role of regulatory bodies in assessing the impact of ionising radiation on wildlife with respect to England and Wales; to make recommendations on the relative biological effectiveness of different types of radiation with respect to wildlife; and to recommend an approach to assess the impacts to wildlife from ionising radiation from authorised discharges in England and Wales, with spreadsheets to support the methodology. The report demonstrates the behaviour and transfer of radionuclides in a number of different ecosystem types. Particular emphasis is placed on exposure pathways in those

  5. Impact assessment of ionising radiation in wildlife

    International Nuclear Information System (INIS)

    2001-01-01

    This R and D project was commissioned by the Environment Agency and English Nature in January 2001 to provide up-to-date information on ionising radiation impact to wildlife, upon which a robust assessment approach may be developed. The methodology will provide an interim approach, whilst awaiting the outcome of the European Commission funded project 'Framework for Assessment of Environmental Impact' (FASSET) due to end in October 2003. The aims of the report were: to summarise the latest research on the behaviour, transfer and impact of ionising radiation effects on wildlife; to outline and review relevant European Directives which have impacted on the requirements to assess the impact to wildlife from ionising radiation in the UK; to consider the role of regulatory bodies in assessing the impact of ionising radiation on wildlife with respect to England and Wales; to make recommendations on the relative biological effectiveness of different types of radiation with respect to wildlife; and to recommend an approach with which to assess the 'scale of risk' to wildlife from the effects of ionising radiation, with spreadsheets to support the methodology. The report describes the behaviour and transfer of radionuclides in a number of different ecosystem types. Particular emphasis is placed on those ecosystems most likely to be impacted by the authorised discharges of radioactivity within the UK. As there is no international consensus on the approach to be taken to assess the impact of ionising radiation on wildlife, some countries have adopted their own legislation. The report evaluates these regulatory frameworks and describe the current UK position

  6. Synthetic diamond devices for radiotherapy applications: Thermoluminescent dosimeter and ionisation chamber

    International Nuclear Information System (INIS)

    Descamps, C.; Tromson, D.; Mer, C.; Nesladek, M.; Bergonzo, P.

    2006-01-01

    In radiotherapy field, the major usage of dosimeters is in the measurement of the dose received by the patient during radiotherapy (in-vivo measurements) and in beam calibration and uniformity checks. Diamond exhibits several interesting characteristics that make it a good candidate for radiation detection. It is indeed soft-tissue equivalent (Z=6 compared to Z=7.42 for human tissue), mechanically robust and relatively insensitive to radiation damage, chemically stable and non toxic. Moreover, the recent availability of synthetic samples, grown under controlled conditions using the chemical vapour deposition (C.V.D.) technique, allowed decreasing the high cost and the long delivery time of diamond devices. Diamond can be use for off-line dosimetry as thermoluminescent dosimeters or for on-line dosimetry as ionisation chamber [2,3]. These both applications are reported here. For this study, samples were grown in the laboratory and devices were then tested under X-ray irradiations and in clinical environment under medical cobalt source. The work described in this paper was performed in the framework of the European Integrated Project M.A.E.S.T.R.O., Methods and Advanced Equipment for Simulation and Treatment in Radio-Oncology, (6. FP) which is granted by the European Commission.The first results of this study clearly show that C.V.D. diamond detectors are suitable for dosimetry in radiotherapy applications. Moreover, for both T.L. dosimeters and ionisation chambers applications, and even though the sensitivity is subsequently reduced, nitrogen incorporation in films seems to significantly improve the dosimetric characteristics of the devices. Therefore, the optimisation of the material quality appears as a very important issue in order to increase the dosimetric characteristics of devices and more particularly, for use as thermoluminescent dosimeters, other impurities (Nickel, Phosphorus) will be tested. For ionisation chamber applications, experiments with

  7. Nucleation in an ultra low ionisation environment

    DEFF Research Database (Denmark)

    Enghoff, Martin Andreas Bødker

    in aerosol nucleation. By exposing a controlled volume of air to varying levels of ionising radiation, and with the minimum ionisation level vastly reduced compared to normal surface laboratory conditions, we have provided both a validation of earlier studies of ion-induced nucleation and extended...

  8. Multi objective optimization of line pack management of gas pipeline system

    International Nuclear Information System (INIS)

    Chebouba, A

    2015-01-01

    This paper addresses the Line Pack Management of the ''GZ1 Hassi R'mell-Arzew'' gas pipeline. For a gas pipeline system, the decision-making on the gas line pack management scenarios usually involves a delicate balance between minimization of the fuel consumption in the compression stations and maximizing gas line pack. In order to select an acceptable Line Pack Management of Gas Pipeline scenario from these two angles for ''GZ1 Hassi R'mell- Arzew'' gas pipeline, the idea of multi-objective decision-making has been introduced. The first step in developing this approach is the derivation of a numerical method to analyze the flow through the pipeline under transient isothermal conditions. In this paper, the solver NSGA-II of the modeFRONTIER, coupled with a matlab program was used for solving the multi-objective problem

  9. Quantification of complex DNA damage by ionising radiation. An experimental and theoretical approach

    International Nuclear Information System (INIS)

    Fulford, J.

    2000-05-01

    Ionising radiation potentially produces a broad spectrum of damage in DNA including single and double strand breaks (ssb and dsb) and base damages. It has been hypothesised that sites of complex damage within cellular DNA have particular biological significance due to an associated decreased efficiency in repair. The aim of this study is to gain further understanding of the formation of complex DNA damage. Irradiations of plasmid DNA illustrate that an increase in ionising density of the radiation results in a decrease in ssb yields/Gy but an increase in dsb per ssb, indicative of an increase in the number of complex damage sites per simple isolated damage site. As the mechanism for damage formation shifts from purely indirect at low scavenging capacities to a significant proportion of direct at higher scavenging capacities the proportion of complex damage increases. Comparisons with the yields of ssb and dsb simulated by Monte-Carlo calculations for Al K USX and α-particles also indicate this correspondence. The ionisation density of low energy, secondary electrons produced by photons was assessed experimentally from the dependence of the yield of OH radicals escaping intra-track recombination on photon energy. As energy decreases the OH radical yield initially decreases reflecting an increased ionisation density. However, with further decrease in photon energy the yield of OH radicals increases in line with theoretical calculations. Base damage yields were determined for low and high ionising density radiation over a range of scavenging capacities. As scavenging capacity increases the base damage: ssb ratios increases implying a contribution from electrons to base damage. It is proposed that base damage contributes to DNA damage complexity. Complex damage analysis reveals that at cell mimetic scavenging capacities, 23% and 72% of ssb have an additional spatially close damage site following γ-ray and α-particle irradiation respectively. (author)

  10. Ionising radiation and trans-generational instability

    International Nuclear Information System (INIS)

    Vrhovac, I.; Niksic, G.

    2007-01-01

    Indirect monitoring of the impact posed by ionising radiation to the genome instability of the descendants, consequent to the irradiation of one of their parents, boils down to the investigation of changes occurring exclusively in the mini-satellite loci of the cells constituting the gametal developmental line. The resultant mini-satellite mutations are expressed in their percentages, and equal to the ratio of the number of mutated alleles in that particular generation over the total number of alleles present. The impact of ionising radiation to the irradiated parent's offspring was first noticed on haematopoietic mouse stem-cells. Even though an irradiated cell of a female parent lacks any mutations whatsoever, daughter cells present with the increased mutation rates. The observed phenomenon of the so called trans-generational instability has been defined as the occurrence of mutations in the genome of individuals originating from the irradiated ancestors. Due to the aforementioned, one can conclude that these mutations need not be present in the irradiated parental cells, and do not necessarily vanish in the next few generations, but may result in the increase in mutation rates observed in the latter. The results of the investigations performed on the animal model, as well as of those carried out in human population, point to the occurrence of significant changes to be found on mini-satellite loci of the descending generation, while the mechanism underlying those changes hasn't been completely clarified yet, and, therefore, calls for the further investigation. (author)

  11. Threshold law for positron-atom impact ionisation

    International Nuclear Information System (INIS)

    Temkin, A.

    1982-01-01

    The threshold law for ionisation of atoms by positron impact is adduced in analogy with the author's approach to the electron-atom ionisation. It is concluded the Coulomb-dipole region of potential gives the essential part of the interaction in both cases and leads to the same kind of result: a modulated linear law. An additional process which enters positron ionisation is positronium formation in the continuum, but that will not dominate the threshold yield. The result is in sharp contrast to the positron threshold law as recently derived by Klar (J. Phys. B.; 14:4165 (1981)) on the basis of a Wannier-type (Phys. Rev.; 90:817 (1953)) analysis. (author)

  12. Working Group on Ionising Radiations. Report 1987-88

    International Nuclear Information System (INIS)

    1989-01-01

    The programme of work for 1987/88 by the Working Group on Ionising Radiation, Health and Safety Commision in February 1988, included the main topics of continuing interest and concern in relation to ionising radiations in general and the Ionising Radiations Regulations 1985 (IRR 85) (Ref 1) in particular. These were: emergency dose limitation, occupational dose limitation, practical experience of the principle of keeping doses as low as reasonably practicable, experience of the regulatory requirements in respect of internal dosimetry and the need for a standing advisory committee on ionising radiations. Calibration of radiotherapy equipment was also considered as a matter of principle following a specific incident involving cancer patients. This report of progress during the first year summarises the Group's opinions on each topic and gives recommendations. (author)

  13. Ionising radiation - physical and biological effects

    International Nuclear Information System (INIS)

    Holter, Oe.; Ingebretsen, F.; Parr, H.

    1979-01-01

    The physics of ionising radiation is briefly presented. The effects of ionising radiation on biological cells, cell repair and radiosensitivity are briefly treated, where after the effects on man and mammals are discussed and related to radiation doses. Dose limits are briefly discussed. The genetic effects are discussed separately. Radioecology is also briefly treated and a table of radionuclides deriving from reactors, and their radiation is given. (JIW)

  14. Organic lining materials test in flue gas ducts

    International Nuclear Information System (INIS)

    Raveh, R.; Sfez, D.; Johannsson, L.

    1998-01-01

    Corrosion protection solutions are being widely used in electric power plants equipped with Flue Gas Desulfurization (FGD) systems. Organic lining materials are one of many solutions available on the market for corrosion protection. This market segment is found in a continuous development in order to fulfill the severe demands of these materials. The main goal of this test is to obtain information about the high temperature resistance of the materials as occurs when the FGD system is by-passed. Aster initial investigation of this market segment only a few lining materials were found compatible according to their manufacturer data. Seven of these materials were installed in the outlet flue gas duct of the Israeli power station M.D. B. This power station is not equipped with a FGD system, thus it gives a real simulation of the environmental conditions into which the lining material is subjected when the FGD system is by-passed. The materials installation was observed carefully and performed by representatives from the manufacturers in order to avoid material failure due to a non-adequate application. The power station was shut down and the lining materials were inspected three and a half months after the lining materials were applied. The inspection results were good and besides changes in the lining color, most materials did not show any damages. During that time the flue gas temperature at the duct was 134?C except some temperature fluctuations

  15. The ionisation balance of C0 to C+4

    International Nuclear Information System (INIS)

    Nussbaumer, H.; Storey, P.J.

    1975-01-01

    The ionisation balance for the ions C 0 -C +4 has been calculated for 10 8 -3 ] 12 and 2 x 10 4 K 5 K. The presence of metastable terms is included in the calculation of the collisional dielectronic recombination and ionisation coefficients. The influence of the observed solar radiation field on the ionisation balance is investigated. Changes in that field do strongly influence the results. (orig.) [de

  16. XUV spectra of highly ionised molybdenum

    Energy Technology Data Exchange (ETDEWEB)

    Mansfield, M W.D.; Peacock, N J; Smith, C C; Hobby, M G [UKAEA, Abingdon. Culham Lab.; Cowan, R D

    1978-05-14

    The spectra of molybdenum ions produced in Tokamaks in the wavelength range 10-200 A have been reproduced in a plasma formed by laser beam irradiation of solid molybdenum targets. Lines from highly ionised stages of molybdenum (Mo XXX to Mo XXXII) have been distinguished by varying the laser beam intensity. Detailed analyses of the simpler ions, Mo XV (Ni-like), Mo XVI (Co-like), Mo XXXII (Na-like), and to a lesser extent Mo XXXI (Mg-like) and Mo XVII (Fe-like), have been achieved by comparison with ab initio calculations. A general interpretation of intermediate ion stages is also given but it is shown that most of these spectra are so complex, as a result of inner-subshell excitation, that detailed term-scheme analyses are nearly impossible.

  17. Generator for ionising radiation

    International Nuclear Information System (INIS)

    Romanovsky, V.F.; Panasjuk, V.S.; Stepanov, B.M.; Ovcharov, A.M.; Akimov, J.A.

    1979-01-01

    The generator for ionising radiation wherein a transmitter for ionising radiation contains a resonance transformer wherein the field coil is composed of a low voltage outside portion and a transformer coil, electrically connected with an electrically conducting housing of the resonance transformer, and an acclerating tube wherein the high voltage electrode is coupled with the high voltage end of the transformer coil of the resonance transformer and fixed to one of the ends of the tubular insulator of the accelerator tube, wherein the low voltage electrode is electrically connected with the housing of the resonance transformer and a source of charged particles is introduced into the evacuated inner space of the acceleration tube and electrically connected with one of the electrodes thereof, is described. (G.C.)

  18. Food ionisation. Realities and perspectives

    International Nuclear Information System (INIS)

    Bonnet, G.

    1994-06-01

    The ionisation of food is a treatment using a certain type of energy. the radiations used in the industrial treatments are limited to three sources. The gamma radiations, the x radiations and the electrons beams emitted with accelerators. The physical treatments by ionizing radiations have for aim to cleanse and to increase the conservation time of food. Now, the applications in agriculture and food industry, are still marginal. The industrial using ionisation are these ones that did not find any alternative decontamination method. The barriers are more scientific or technical or economical than a question of regulation or behaviour. (N.C.)

  19. Powerloads on the front end components and the duct of the heating and diagnostic neutral beam lines at ITER

    Energy Technology Data Exchange (ETDEWEB)

    Singh, M. J.; Boilson, D.; Hemsworth, R. S.; Geli, F.; Graceffa, J.; Urbani, M.; Schunke, B.; Chareyre, J. [ITER Organisation, 13607 St. Paul-Lez-Durance Cedex (France); Dlougach, E.; Krylov, A. [RRC Kurchatov institute, 1, Kurchatov Sq, Moscow, 123182 (Russian Federation)

    2015-04-08

    The heating and current drive beam lines (HNB) at ITER are expected to deliver ∼16.7 MW power per beam line for H beams at 870 keV and D beams at 1 MeV during the H-He and the DD/DT phases of ITER operation respectively. On the other hand the diagnostic neutral beam (DNB) line shall deliver ∼2 MW power for H beams at 100 keV during both the phases. The path lengths over which the beams from the HNB and DNB beam lines need to be transported are 25.6 m and 20.7 m respectively. The transport of the beams over these path lengths results in beam losses, mainly by the direct interception of the beam with the beam line components and reionisation. The lost power is deposited on the surfaces of the various components of the beam line. In order to ensure the survival of these components over the operational life time of ITER, it is important to determine to the best possible extent the operational power loads and power densities on the various surfaces which are impacted by the beam in one way or the other during its transport. The main factors contributing to these are the divergence of the beamlets and the halo fraction in the beam, the beam aiming, the horizontal and vertical misalignment of the beam, and the gas profile along the beam path, which determines the re-ionisation loss, and the re-ionisation cross sections. The estimations have been made using a combination of the modified version of the Monte Carlo Gas Flow code (MCGF) and the BTR code. The MCGF is used to determine the gas profile in the beam line and takes into account the active gas feed into the ion source and neutraliser, the HNB-DNB cross over, the gas entering the beamline from the ITER machine, the additional gas atoms generated in the beam line due to impacting ions and the pumping speed of the cryopumps. The BTR code has been used to obtain the power loads and the power densities on the various surfaces of the front end components and the duct modules for different scenarios of ITER

  20. On-line gas chromatographic analysis of airborne particles

    Science.gov (United States)

    Hering, Susanne V [Berkeley, CA; Goldstein, Allen H [Orinda, CA

    2012-01-03

    A method and apparatus for the in-situ, chemical analysis of an aerosol. The method may include the steps of: collecting an aerosol; thermally desorbing the aerosol into a carrier gas to provide desorbed aerosol material; transporting the desorbed aerosol material onto the head of a gas chromatography column; analyzing the aerosol material using a gas chromatograph, and quantizing the aerosol material as it evolves from the gas chromatography column. The apparatus includes a collection and thermal desorption cell, a gas chromatograph including a gas chromatography column, heated transport lines coupling the cell and the column; and a quantization detector for aerosol material evolving from the gas chromatography column.

  1. X-ray spectroscopy of highly ionised atoms of Ti through Zn in a dense plasma

    International Nuclear Information System (INIS)

    Morita, Shiguro; Fujita, Junji

    1985-01-01

    X-ray spectra for several elements have been observed from a high-temperature plasma produced in a vacuum spark using a curved-crystal spectrometer. The transition wavelengths of the He-like resonance lines for Ti through Zn are determined for the first time under careful experimental treatments. The result is compared with theoretical predictions. The transition wavelengths of the Fe He-like resonance series lines up to 1s6p-1s 2 and the Kβ transition energies of Ti partially M-shell-ionised ions (Ti VI-XIII) are also determined. As a result, several satelite lines are found. (orig.)

  2. Ionisation of hydrogen-like atoms by a multiphoton absorption process; Ionisation des atomes hydrogenoides par un processus d'absorption multiphotonique

    Energy Technology Data Exchange (ETDEWEB)

    Gontier, Y; Trahin, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    The general expression for the amplitude of the probability of ionisation by a multiphoton absorption process is derived. Its non-relativistic limit is taken and the bipolar approximation is used for calculating the ionisation cross-section of hydrogen-like atoms. This latter involves the summation over intermediate virtual states by means of: a) a recursion relationship concerning angular functions, b) a particular technique which when applied to radial functions makes it possible to solve a system of inhomogeneous first-order differential equations. (authors) [French] On etablit l'expression generale de l'amplitude de probabilite d'ionisation par un processus d'absorption multiphotonique. On en prend la limite non-relativiste et l'on utilise l'approximation dipolaire avant de calculer la section efficace d'ionisation d'atomes hydrogenoides. Cette derniere fait intervenir des sommations sur des etats virtuels intermediaires effectuees a l'aide: a) d'une relation de recurrence qui concerne les fonctions angulaires, b) d'une technique particuliere qui, appliquee aux fonctions radiales, conduit a resoudre un systeme d'equations differentielles inhomogenes du premier ordre. (auteur)

  3. Broad-line high-excitation gas in the elliptical galaxy NGC5128

    International Nuclear Information System (INIS)

    Phillips, M.M.; Taylor, K.; Axon, D.J.; Atherton, P.D.; Hook, R.N.

    1984-01-01

    A faint, but extensive component of broad-line ionized gas has been discovered in the peculiar giant elliptical galaxy NGC5128. This component has a radically different spatial distribution from the well-studied rotating photoionized gas associated with the dust lane although the velocity fields of the two components are similar. The origin of the broad-line gas is considered as its possible relation to the active nucleus and the X-ray jet discussed. (author)

  4. Studies of the electron-impact double-ionisation process in magnesium using coincidence techniques

    International Nuclear Information System (INIS)

    Ford, M.J.

    1998-01-01

    This article will review recent measurements of the electron-impact double-ionisation of atomic magnesium. Results for the resonant Auger double-ionisation process with coincident detection of all three outgoing electrons, the (e, 3e) experiment, and for the direct double-ionisation process where only two outgoing electrons are detected, the (e, (3 -1)e) experiment, will be discussed. The results are analysed with reference to ionisation mechanisms and comparisons are made with calculated double-ionisation cross sections. Copyright (1998) CSIRO Australia

  5. Bi-Abundance Ionisation Structure of the Wolf-Rayet Planetary Nebula PB 8

    Science.gov (United States)

    Danehkar, A.

    2018-01-01

    The planetary nebula PB 8 around a [WN/WC]-hybrid central star is one of planetary nebulae with moderate abundance discrepancy factors (ADFs 2-3), which could be an indication of a tiny fraction of metal-rich inclusions embedded in the nebula (bi-abundance). In this work, we have constructed photoionisation models to reproduce the optical and infrared observations of the planetary nebula PB 8 using a non-LTE stellar model atmosphere ionising source. A chemically homogeneous model initially used cannot predict the optical recombination lines. However, a bi-abundance model provides a better fit to most of the observed optical recombination lines from N and O ions. The metal-rich inclusions in the bi-abundance model occupy 5.6% of the total volume of the nebula, and are roughly 1.7 times cooler and denser than the mean values of the surrounding nebula. The N/H and O/H abundance ratios in the metal-rich inclusions are 1.0 and 1.7 dex larger than the diffuse warm nebula, respectively. To reproduce the Spitzer spectral energy distribution of PB 8, dust grains with a dust-to-gas ratio of 0.01 (by mass) were also included. It is found that the presence of metal-rich inclusions can explain the heavy element optical recombination lines, while a dual-dust chemistry with different grain species and discrete grain sizes likely produces the infrared continuum of this planetary nebula. This study demonstrates that the bi-abundance hypothesis, which was examined in a few planetary nebulae with large abundance discrepancies (ADFs > 10), could also be applied to those typical planetary nebulae with moderate abundance discrepancies.

  6. Spin Start Line Effects on the J2X Gas Generator Chamber Acoustics

    Science.gov (United States)

    Kenny, R. Jeremy

    2011-01-01

    The J2X Gas Generator engine design has a spin start line connected near to the turbine inlet vanes. This line provides helium during engine startup to begin turbomachinery operation. The spin start line also acts as an acoustic side branch which alters the chamber's acoustic modes. The side branch effectively creates 'split modes' in the chamber longitudinal modes, in particular below the first longitudinal mode and within the frequency range associated with the injection-coupled response of the Gas Generator. Interaction between the spin start-modified chamber acoustics and the injection-driven response can create a higher system response than without the spin start attached to the chamber. This work reviews the acoustic effects of the spin start line as seen throughout the workhorse gas generator test program. A simple impedance model of the spin start line is reviewed. Tests were run with no initial spin start gas existing in the line, as well as being initially filled with nitrogen gas. Tests were also run with varying spin start line lengths from 0" to 40". Acoustic impedance changes due to different spin start gas constituents and line lengths are shown. Collected thermocouple and static pressure data in the spin start line was used to help estimate the fluid properties along the line length. The side branch impedance model was coupled to a chamber impedance model to show the effects on the overall chamber response. Predictions of the spin start acoustic behavior for helium operation are shown and compared against available data.

  7. Health Service use of ionising radiations: Guidance

    International Nuclear Information System (INIS)

    1995-01-01

    This booklet gives outline guidance on the use of ionising radiations in the Health Service in the United Kingdom. Extensive reference is made to documents where more detailed information may be found. The guidance covers general advice on the medical use of ionising radiations, statutory requirements, and guidance on selected Health Service issues such as patient identification procedures, information management systems, deviations from prescribed radiation dose, imaging and radiotherapy. (57 references) (U.K.)

  8. The XUV spectra of highly ionised molybdenum

    International Nuclear Information System (INIS)

    Mansfield, M.W.D.; Peacock, N.J.; Smith, C.C.; Hobby, M.G.; Cowan, R.D.

    1978-01-01

    The spectra of molybdenum ions produced in Tokamaks in the wavelength range 10-200 A have been reproduced in a plasma formed by laser beam irradiation of solid molybdenum targets. Lines from highly ionised stages of molybdenum (Mo XXX to Mo XXXII) have been distinguished by varying the laser beam intensity. Detailed analyses of the simpler ions, Mo XV (Ni-like), Mo XVI (Co-like), Mo XXXII (Na-like), and to a lesser extent Mo XXXI (Mg-like) and Mo XVII (Fe-like), have been achieved by comparison with ab initio calculations. A general interpretation of intermediate ion stages is also given but it is shown that most of these spectra are so complex, as a result of inner-subshell excitation, that detailed term-scheme analyses are nearly impossible. (author)

  9. Ionising radiation

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    The law covering ionising radiation in Luxembourg is summarised under the headings: introduction (the outline law of 25 March 1963, and the Grand-Ducal Decree of 8 February 1967); the control of establishments (the authorisation procedure; emergency measures, suspension and withdrawal of the authorisation; alterations to the establishment); the importation, distribution and transit of radioactive substances; the transport of radioactive substances; the protection and safety of the population as a whole; sanctions; international conventions. (U.K.)

  10. Innershell ionisation at small impactparameters in proton-atom collisions

    International Nuclear Information System (INIS)

    Duinker, W.

    1981-01-01

    This thesis concentrates on innershell ionisation in proton-atom collisions. An experiment on K-shell ionisation of argon is described, performed in a gasfilled collision chamber under single collision conditions. Further experiments with carbon and aluminium were performed, the K-shell vacancy production in the collision of protons with these atoms being detected through the measurement of Auger-electrons. A spectrometer with a large solid angle was specially constructed for this and its performance is described. K-shell ionisation accompanying nuclear (p,γ) reactions has also been measured using 26 Mg and 27 Al. (Auth./C.F.)

  11. Coupled-states calculations of argon L-shell impact ionisation

    International Nuclear Information System (INIS)

    Martir, M.H.; Ford, A.L.; Reading, J.F.

    1982-01-01

    A coupled-states method is used to calculate the corrections to the first Born approximation for L-shell impact ionisation in the ion-atom collisions p+Ar and α+Ar at energies between 100 and 850 keV amu -1 . Using a classical projectile path and a pseudostate description of the ionisation continuum, the pseudostate and partial-wave convergence is considered. It is found that the absolute cross sections for these collisions are sensitive to the particular independent-particle-model (IPM) target-atom potential which is used. A modification to the long-range part of the neutral-atom Hartree-Fock (HF) potential is proposed that lowers the energy of the unbound pseudostates and that thereby brings the L-shell removal energies closer to the experimental ionisation potentials. With this modified HF potential good agreement between the present L-shell ionisation cross sections and experimental L-vacancy production cross sections is found. (author)

  12. Electron spectroscopy of He and NO using electron impact and multiphoton ionisation

    International Nuclear Information System (INIS)

    Kimman, J.T.N.

    1984-01-01

    This thesis describes two experimental studies which are intended to contribute to our knowledge of the structure of molecules and the decay dynamics of excited molecular states. The two studies have in common that they are both concerned with ionisation processes, in which an accurately known amount of energy is transferred to the target, and energy analysis of the ejected electrons is made. Ionisation is caused either by scattering electrons off the molecules (chapter 2: electron impact ionisation) or by a simultaneous absorption of several photons (chapter 3: multiphoton ionisation). In chapter 2 an electron impact ionisation experiment on Helium is described in which the kinematics of both the scattered and the ejected electrons is fully determined ((e,2e) experiment). (Auth.)

  13. Generation and confinement of microwave gas-plasma in photonic dielectric microstructure.

    Science.gov (United States)

    Debord, B; Jamier, R; Gérôme, F; Leroy, O; Boisse-Laporte, C; Leprince, P; Alves, L L; Benabid, F

    2013-10-21

    We report on a self-guided microwave surface-wave induced generation of ~60 μm diameter and 6 cm-long column of argon-plasma confined in the core of a hollow-core photonic crystal fiber. At gas pressure of 1 mbar, the micro-confined plasma exhibits a stable transverse profile with a maximum gas-temperature as high as 1300 ± 200 K, and a wall-temperature as low as 500 K, and an electron density level of 10¹⁴ cm⁻³. The fiber guided fluorescence emission presents strong Ar⁺ spectral lines in the visible and near UV. Theory shows that the observed combination of relatively low wall-temperature and high ionisation rate in this strongly confined configuration is due to an unprecedentedly wide electrostatic space-charge field and the subsequent ion acceleration dominance in the plasma-to-gas power transfer.

  14. On-line coupling of a microelectrode array equipped poly(dimethylsiloxane) microchip with an integrated graphite electrospray emitter for electrospray ionisation mass spectrometry.

    Science.gov (United States)

    Liljegren, Gustav; Dahlin, Andreas; Zettersten, Camilla; Bergquist, Jonas; Nyholm, Leif

    2005-10-01

    A novel method for the manufacturing of microchips for on-chip combinations of electrochemistry (EC) and sheathless electrospray ionisation mass spectrometry (ESI-MS) is described. The technique, which does not require access to clean-room facilities, is based on the incorporation of an array of gold microcoil electrodes into a poly(dimethylsiloxane)(PDMS) microflow channel equipped with an integrated graphite based sheathless ESI emitter. Electrochemical measurements, which were employed to determine the electroactive area of the electrodes and to test the microchips, show that the manufacturing process was reproducible and that the important interelectrode distance in the electrochemical cell could to be adequately controlled. The EC-ESI-MS device was evaluated based on the ESI-MS detection of the oxidation products of dopamine. The results demonstrate that the present on-chip approach enables full potentiostatic control of the electrochemical cell and the attainment of very short transfer times between the electrochemical cell and the electrospray emitter. The transfer times were 0.6 and 1.2 s for flow rates of 1.0 and 0.5 microL min(-1), respectively, while the electrochemical conversion efficiency of the electrochemical cell was found to be 30% at a flow rate of 0.5 microL min(-1). To decouple the electrochemical cell from the ESI-MS high voltage and to increase the user-friendliness, the on-line electrochemistry-ESI-MS experiments were performed using a wireless Bluetooth battery-powered instrument with the chip floating at the potential induced by the ESI high voltage. The described on-chip EC-ESI-MS device can be used for fundamental electrochemical investigations as well as for applications based on the use of electrochemically controlled sample pretreatment, preconcentration and ionisation steps prior to ESI-MS.

  15. Medical exposure to ionising radiation and the risk of brain tumours

    DEFF Research Database (Denmark)

    Blettner, Maria; Schlehofer, Brigitte; Samkange-Zeeb, Florence

    2007-01-01

    BACKGROUND: The role of exposure to low doses of ionising radiation in the aetiology of brain tumours has yet to be clarified. The objective of this study was to investigate the association between medically or occupationally related exposure to ionising radiation and brain tumours. METHODS: We...... used self-reported medical and occupational data collected during the German part of a multinational case-control study on mobile phone use and the risk of brain tumours (Interphone study) for the analyses. RESULTS: For any exposure to medical ionising radiation we found odds ratios (ORs) of 0.63 (95...... regions. CONCLUSION: We did not find any significant increased risk of brain tumours for exposure to medical ionising radiation....

  16. Setting up and performance of a laser enhanced ionisation spectrometer

    International Nuclear Information System (INIS)

    Chandola, L.C.; Khanna, P.P.; Razvi, M.A.N.

    1990-01-01

    A laser enhanced ionisation (LEI) spectrometer has been successfuly set up around an excimer laser pumped dye laser. The performance of the spectrometer has been tested by analysing sodium in water solutions. A straight line working curve has been obtained in the concentration range of 1-1000 ng/ml of Na. The effect of parameters like laser power, ion collector electrode voltage and the load resistance on LEI signals has been investigated. The spectrometer is useful not only for analytical purposes but also for laser spectroscopic studies of species formed in flames, study of phenomenon of combustion etc. (author). 1 tab ., 10 figs., 5 refs

  17. Nanoscale photoelectron ionisation detector based on lanthanum hexaboride

    International Nuclear Information System (INIS)

    Zimmer, C.M.; Kunze, U.; Schubert, J.; Hamann, S.; Doll, T.

    2011-01-01

    A nanoscale ioniser is presented exceeding the limitation of conventional photoionisation detectors. It employs accelerated photoelectrons that allow obtaining molecule specificity by the tuning of ionisation energies. The material lanthanum hexaboride (LaB 6 ) is used as air stable photo cathode. Thin films of that material deposited by pulsed laser deposition (PLD) show quantum efficiency (QE) in the range of 10 -5 which is comparable to laser photo stimulation results. A careful treatment of the material yields reasonable low work functions even after surface reoxidation which opens up the possibility of using ultraviolet light emitting diodes (UV LEDs) in replacement of discharge lamps. Schematic diagram of a photoelectron ionisation detector (PeID) operating by an electron emitter based on the photoelectric effect of lanthanum hexaboride. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  18. Semiclassical calculation of ionisation rate for Rydberg helium atoms in an electric field

    International Nuclear Information System (INIS)

    Wang De-Hua

    2011-01-01

    The ionisation of Rydberg helium atoms in an electric field above the classical ionisation threshold has been examined using the semiclassical method, with particular emphasis on discussing the influence of the core scattering on the escape dynamics of electrons. The results show that the Rydberg helium atoms ionise by emitting a train of electron pulses. Unlike the case of the ionisation of Rydberg hydrogen atom in parallel electric and magnetic fields, where the pulses of the electron are caused by the external magnetic field, the pulse trains for Rydberg helium atoms are created through core scattering. Each peak in the ionisation rate corresponds to the contribution of one core-scattered combination trajectory. This fact further illustrates that the ionic core scattering leads to the chaotic property of the Rydberg helium atom in external fields. Our studies provide a simple explanation for the escape dynamics in the ionisation of nonhydrogenic atoms in external fields. (atomic and molecular physics)

  19. On-Line Enrichment Monitor for UF{sub 6} Gas Centrifuge Enrichment Plant

    Energy Technology Data Exchange (ETDEWEB)

    Ianakiev, K. D.; Boyer, B.; Favalli, A.; Goda, J. M.; Hill, T.; Keller, C.; Lombardi, M.; Paffett, M.; MacArthur, D. W.; McCluskey, C.; Moss, C. E.; Parker, R.; Smith, M. K.; Swinhoe, M. T. [Los Alamos National Laboratory, Los Alamos (United States)

    2012-06-15

    This paper is a continuation of the Advanced Enrichment Monitoring Technology for UF{sub 6} Gas Centrifuge Enrichment Plant (GCEP) work, presented in the 2010 IAEA Safeguards Symposium. Here we will present the system architecture for a planned side-by-side field trial test of passive (186-keV line spectroscopy and pressure-based correction for UF{sub 6} gas density) and active (186-keV line spectroscopy and transmission measurement based correction for UF{sub 6} gas density) enrichment monitoring systems in URENCO's enrichment plant in Capenhurst. Because the pressure and transmission measurements of UF{sub 6} are complementary, additional information on the importance of the presence of light gases and the UF{sub 6} gas temperature can be obtained by cross-correlation between simultaneous measurements of transmission, pressure and 186-keV intensity. We will discuss the calibration issues and performance in the context of accurate, on-line enrichment measurement. It is hoped that a simple and accurate on-line enrichment monitor can be built using the UF{sub 6} gas pressure provided by the Operator, based on online mass spectrometer calibration, assuming a negligible (a small fraction of percent) contribution of wall deposits. Unaccounted-for wall deposits present at the initial calibration will lead to unwanted sensitivity to changes in theUF{sub 6} gas pressure and thus to error in the enrichment results. Because the accumulated deposits in the cascade header pipe have been identified as an issue for Go/No Go measurements with the Cascade Header Enrichment Monitor (CHEM) and Continuous Enrichment Monitor (CEMO), it is important to explore their effect. Therefore we present the expected uncertainty on enrichment measurements obtained by propagating the errors introduced by deposits, gas density, etc. and will discuss the options for a deposit correction during initial calibration of an On-Line Enrichment Monitor (OLEM).

  20. Disposal regulations and techniques applicable to devices using ionising radiation

    International Nuclear Information System (INIS)

    Vidal, J.P.

    1998-01-01

    L'office de Protection contre les rayonnement ionisants, being a government body under the supervision of Ministry of Health and Labour, among other different missions controls the compliance of radiation protection laws with the aim to guarantee the safe operation of equipment using ionising radiation sources. These regulations concerning competence of personnel, especially in the field of medicine or application of ionising radiation on humans, are restricted only to medical doctors (or dentists in their domain) by technical constraints dealing with design of equipment and its exploitation. At the same time regulations define conditions of permanent control in order to verify compliance of radiation protection laws

  1. Distorted-wave calculations of electron impact ionisation in the Ni isonuclear sequence

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, D C; Pindzola, M S

    1988-10-14

    Electron impact ionisation cross sections for Ni/sup +/, Ni/sup 3+/, Ni/sup 5+/, Ni/sup 6+/, Ni/sup 7+/, Ni/sup 8+/, Ni/sup 12+/, Ni/sup 14+/, and Ni/sup 16+/ are calculated in the distorted-wave approximation. These calculations include contributions from direct ionisation and inner-shell excitation followed by autoionisation. For Ni/sup 12+/, Ni/sup 14+/, and Ni/sup 16+/ we report not only on ionisation cross sections from the ground states but also from the metastable states of these ions. Experimental cross section measurements exist for all ions reported here, except Ni/sup 16+/. The agreement between experiment and theory is reasonably good and improves with ionisation stage.

  2. Measurement of the activity of beta emitting gases using an ionisation chamber; Mesure de l'activite des gaz emetteurs beta au moyen d'une chambre d'ionisation

    Energy Technology Data Exchange (ETDEWEB)

    Lebouleux, P [Commissariat a l' Energie Atomique. Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)

    1962-07-01

    An ionization chamber was developed for measuring directly the activity of a {beta}-emitting gas whatever the gas may be. The following two parameters are defined and determined: p, the average specific ionization produced by a {beta} disintegration, and i, the average {beta} path in the chamber. It was shown, during the determination of i, that the {beta} particles are reflected on the walls of the ionization chamber when the latter are made of a high atomic number material. It was possible to eliminate this effect by constructing an electrode chamber made of graphite. With this chamber a direct measurement can be made of the activity of a gaseous {beta} emitter with a precision of about {+-}10%. Some applications are given of the graphite electrode chamber (calibration of the chambers built industrially and determination of the activation cross section of a gaseous emitter). It was possible to determine the activation cross section of {sup 134}Xe; a value of 0.18 {+-} 0.03 barn was found. (author) [French] Le but de l'etude est de realiser une chambre d'ionisation permettant d'effectuer une mesure directe de l'activite d'un gaz emetteur {beta} quel que soit l'emetteur considere. On definit et l'on determine les deux parametres suivants: p: ionisation specifique moyenne produite par une desintegration {beta}. La determination est effectuee par une methode graphique, i: moyenne des parcours des {beta} dans la chambre. La determination est effectuee experimentalement par introduction dans la chambre d'un gaz radioactif dont on peut calculer l'activite. On a mis en evidence, au cours de la determination de i, la reflexion des particules {beta} sur les parois des chambres d'ionisation lorsque celles-ci sont constituees d'un materiau de numero atomique eleve. La construction d'une chambre a electrodes de graphite nous a permis d'eliminer ce phenomene. Avec cette chambre, on effectue une mesure directe de l'activite d'un emetteur {beta} gazeux avec une precision de l

  3. Ionisation Chambers for the LHC Beam Loss Detection

    CERN Document Server

    Gschwendtner, E; Dehning, B; Ferioli, G; Kain, V

    2003-01-01

    At the Large Hadron Collider (LHC) a beam loss system will be used to prevent and protect superconducting magnets against coil quenches and coil damages. Since the stored particle beam intensity is 8 orders of magnitude larger than the lowest quench level value particular attention is paid to the design of the secondary particle shower detectors. The foreseen ionisation chambers are optimised in geometry simulating the probable loss distribution along the magnets and convoluting the loss distribution with the secondary particle shower distributions. To reach the appropriate coverage of a particle loss and to determine the quench levels with a relative accuracy of 2 the number of the detectors and their lengths is weighted against the particle intensity density variation. In addition attention is paid to the electrical ionisation chamber signal to minimise the ion tail extension. This optimisation is based on time resolved test measurements in the PS booster. A proposal for a new ionisation chamber will be pre...

  4. High spatial and time resolutions with gas ionization detectors; Hautes resolutions en position et temps avec des detecteurs gazeux a ionisation

    Energy Technology Data Exchange (ETDEWEB)

    Pouthas, J

    2001-09-01

    This document presents the principles and the characteristics of the gaseous ionisation detectors used in position and timing measurements. The first two parts recall the main notions (electron and ion motions, gaseous amplification, signal formation) and their applications to the proportional counter and the wire chamber. The explanation of the signal formation makes use of the Ramo theorem. The third part is devoted to the different types of wire chambers: drift or cathode strip chambers, TPC (time projection chamber). Some aspects on construction and ageing are also presented. Part 4 is on the detectors in which the multiplication is performed by a 'Parallel Plate' system (PPAC, Pestov counter). Special attention is paid to the RPCs (Resistive Plate Chambers) and their timing resolutions. Part 5 concentrates on 'Micro-pattern detectors' which use different kinds of microstructure for gaseous amplification. The new detectors MICROMEGAS, CAT (compteur a trous) and GEM (gas electron multiplier) and some of their applications are presented. The last part is a bibliography including some comments on the documents. (author)

  5. Genetic analysis among selected vernonia lines through seed oil ...

    African Journals Online (AJOL)

    PRECIOUS

    2010-01-11

    Jan 11, 2010 ... Vernonia (Vernonia galamensis) is a new potential industrial oilseed crop. The seeds .... Syferkuil, the university of Limpopo's experimental farm. The farm ... ionisation gas chromatograph, with a fused silica capillary column,.

  6. The possibility of lasing in Ne+Ar ionic molecules pumped by a hard ioniser

    International Nuclear Information System (INIS)

    Boichenko, Aleksandr M; Yakovlenko, Sergei I

    2000-01-01

    The kinetic model of relaxation in the Ne-Ar-Kr mixture pumped by a hard ioniser is constructed in connection with the analysis of the possibility of lasing at the Ne + Ar→NeAr + transition of the inert-gas ionic exciplexes. The calculations based on the typical rates of plasmachemical reactions demonstrate that the lasing is possible but difficult to realise: One needs high pressures (greater than 16 bar) and high pumping densities (∼ 1 MW cm -3 ). In the most favourable cases, the laser efficiency lies between 0.05 and 0.25%. (active media)

  7. The case against protecting the environment from ionising radiation

    International Nuclear Information System (INIS)

    Smith, J.T.

    2004-01-01

    The objective of this paper is to present the (rarely heard) argument in favour of retention of the present system of radiation protection of the environment. There has been a recent trend in the radioecological and radiation protection community towards greater regulation of the effects of ionising radiations on biota. In particular, the often quoted International Commission on Radiation Protection (ICRP) hypothesis that: If humans are protected from the effects of ionising radiation, then flora and fauna are also adequately protected has been criticised as being too anthropocentric and not adequate for protection of the environment. In this paper I will challenge this view, arguing firstly that this statement is almost always quoted out of its proper context, and secondly that the ICRP hypothesis does adequately protect the environment from the effects of ionising radiations. In view of the relatively insignificant effect of regulated releases of ionising radiation on the environment, the economic cost of further regulation will not result in a significant environmental benefit. Whilst empirical research to test the ICRP hypothesis should continue, until there is clear evidence against it, this simple and cost-effective approach should be retained. This would benefit the environment by directing scarce resources to more urgent environmental problems. (author)

  8. A micro-gap, air-filled ionisation chamber as a detector for criticality accident dosimetry

    International Nuclear Information System (INIS)

    Murawski, I.; Zielczynski, M.; Gryzinski, M.A.; Golnik, N.

    2014-01-01

    A micro-gap air-filled ionisation chamber was designed for criticality dosimetry. The special feature of the chamber is its very small gap between electrodes of only 0.3 mm. This prevents ion recombination at high dose rates and minimises the influence of gas on secondary particles spectrum. The electrodes are made of polypropylene because of higher content of hydrogen in this material, when compared with soft tissue. The difference between neutron and gamma sensitivity in such chamber becomes practically negligible. The chamber's envelope contains two specially connected capacitors, one for polarising the electrodes and the other for collecting the ionisation charge. Air-filled ionisation chamber with very small gap is a simple dosemeter, which fulfills the most desired properties of criticality accident dosemeters. Short ion collection time is achieved by combination of small gap and relatively high polarising voltage. For the same reason, parasitic recombination of ions in the chamber is negligibly small even at high dose rates. The difference between neutron and gamma sensitivity is small for tissue-equivalent chamber and is expected to become practically negligible when the chamber electrodes are made of polypropylene. Additional capacitor provides a broad measuring range from ∼0.1 Gy up to ∼25 Gy; however, leakage of electrical charge from polarising capacitor has to be observed and taken into account. Periodical re-charging of the device is necessary. Obviously, final test of the device in conditions simulating criticality accident is needed and will be performed as soon as available. (authors)

  9. Making ionising radiation a real experience for high school science students

    International Nuclear Information System (INIS)

    Whitlock, J.; Lang, P.; De La Matter, D.; Hinman, P.; White, B.

    2009-01-01

    The Canadian public has little understanding of ionising radiation due in part to its treatment in popular media. In principle, students learn about ionising radiation in their school science classes. Developments in science curricula are providing more education opportunities for this subject. The Canadian Nuclear Society's program for introducing real, personal experience with ionising radiation in the classroom is starting to make a difference. The demand is expected to exceed the resources of the CNS and the program is being developed to facilitate external support. This paper summarizes the need, the history of this program development, and the path forward. (author)

  10. Critical ionisation velocity and the dynamics of a coaxial plasma gun

    International Nuclear Information System (INIS)

    Raadu, M.A.

    1978-01-01

    The dynamics of an ionising wave in a coaxial plasma gun with an azimuthal bias magnetic field is analysed in a theoretical model. Only the radial dependence is treated and instead of including a treatment of the energy balance two separate physical assumptions are made. In the first case it is assumed that the total internal electric field is given by the critical ionisation velocity condition and in the second that the ionisation rate is constant. For consistency wall sheaths are assumed to match the internal plasma potential to that of the walls. On the basis of momentum and particle balance the radial dependence of the electron density, current density, electric field and drift velocity are found. An electron source is required at the cathode and the relative contribution from ionisation within the plasma is deduced. The assumption that there are no ion sources at the electrodes leads to a restriction on the possible values of the axial electric field. (author)

  11. Antioxidant Protection in Blood against Ionising Radiation

    International Nuclear Information System (INIS)

    Bognar, G.; Meszaros, G.; Koteles, G. J.

    2001-01-01

    Full text: The quantities of the antioxidants in the human blood are important indicators of health status. The routine determinations of activities/capacities of antioxidant compounds would be of great importance in assessing individual sensitivities against oxidative effects. We have investigated the sensitivities of those antioxidant elements against various doses of ionising radiation tested by the RANDOX assays. Our results show dose-dependent decreases of antioxidant activities caused by the different doses. The total antioxidant status value linearly decreased up to 1 Gy, but further increase of dose (2 Gy) did not influence the respective values although the test system still indicated their presence. It means that the human blood retains 60-70% of its total antioxidant capacity. Radiation induced alterations of the antioxidant enzymes: glutathione peroxidase and superoxide dismutase have been also investigated. The activities of glutathione peroxidase and superoxide dismutase decreased linearly upon the effects of various doses of ionising radiation till 1 Gy. Between 1 and 2 Gy only further mild decreases could be detected. In this case the human blood retained 40-60% of these two antioxidant enzymes. These observations suggest either the limited response of antioxidant system against ionising radiation, or the existence of protection system of various reactabilities. (author)

  12. Working safely with ionising radiation

    International Nuclear Information System (INIS)

    McDowell, D.J.

    1990-01-01

    A small leaflet provides information on working safely with ionizing radiation. Topics covered include the types of radiation, radiological units, external radiation, contamination and internal radiation, methods of protection form radiation, radiation monitors, protective clothing for contamination, personal dosemeters, radiation dose limits for classified workers and finally the Ionising Radiations Regulations 1985. (UK)

  13. Comparative study of aerial transmission lines and underground isolated on gas

    International Nuclear Information System (INIS)

    Quesada Jimenez, Marco Esteban

    2012-01-01

    A comparison was made of aerial power lines and underground isolated on gas. Growing electric demand has given way to debate the lines transmission. Multiple discussions have generated about its application, however, the energy must be supplied and this process leads to the search for more efficient methods. The theory has covered the most important design criteria of the airlines and an introduction to the little known transport lines isolated on gas. The process of manufacturing, installation and operation are studied within the scope of the project. Count information is included in the main aspects of calculation relating to power transmission. Besides, the planning of the optimal route nominal calculations, load flow and power losses are focused as well as magnetic field strengths and finally economic analysis. (author) [es

  14. Beam Cooling with ionisation losses

    CERN Document Server

    Rubbia, Carlo; Kadi, Y; Vlachoudis, V

    2006-01-01

    A novel type of particle "cooling", called Ionization Cooling, is applicable to slow (v of the order of 0.1c) ions stored in a small ring. The many traversals through a thin foil enhance the nuclear reaction probability, in a steady configuration in which ionisation losses are recovered at each turn by a RF-cavity. For a uniform target "foil" the longitudinal momentum spread diverges exponentially since faster (slower) particles ionise less (more) than the average. In order to "cool" also longitudinally, a chromaticity has to be introduced with a wedge shaped "foil". Multiple scattering and straggling are then "cooled" in all three dimensions, with a method similar to the one of synchrotron cooling, but valid for low energy ions. Particles then stably circulate in the beam indefinitely, until they undergo for instance nuclear processes in the thin target foil. This new method is under consideration for the nuclear production of a few MeV/A ion beams. Simple reactions, for instance Li 7 + D Li 8 + p, are more ...

  15. Calibration of ARI QC ionisation chambers using the Australian secondary standards for activity

    International Nuclear Information System (INIS)

    Mo, L.; Van Der Gaast, H.A.; Alexiev, D.; Butcher, K.S.A.; Davies, J.

    1999-01-01

    The Secondary Standard Activity Laboratory (SSAL) in ANSTO routinely provides standardised radioactive sources, traceable activity measurements and custom source preparation services to customers. The most important activity carried out is the calibration of ionisation chambers located in the Quality Control (QC) section of Australian Radioisotopes (ARI). This ensures that their activity measurements are traceable to the Australian primary methods of standardisation. ARI QC ionisation chambers are calibrated for 99m Tc, 67 Ga, 131 I, 201 Tl and 153 Sm. The SSAL has a TPA ionisation chamber, which has been directly calibrated against a primary standard for a variety of radioactive nuclides. Calibration factors for this chamber were determined specifically for the actual volumes (5ml for 99m Tc, 131 I, 2ml for 67 Ga, 201 Tl and 3 ml for 153 Sm) and types of vial (Wheaton) which are routinely used at ARI. These calibration factors can be used to accurately measure the activity of samples prepared by ARI. The samples can subsequently be used to calibrate the QC ionisation chambers. QC ionisation chambers are re-calibrated biannually

  16. Ionising radiation. Part 2

    International Nuclear Information System (INIS)

    2000-01-01

    A brief tutorial on the health effects of ionising radiation is presented. The distinction between somatic and genetic health effects is explained. The two types of somatic health effects, i.e., acute and chronic effects, are discussed, as well as the concepts of ''deterministic'' and ''stochastic'' (also called ''probabilistic'') health effects. The possibility of cancer caused by DNA damage is discussed. The document ends with the definition of some key radiation terms

  17. IRID: specifications for the Ionising Radiations Incident Database

    International Nuclear Information System (INIS)

    Thomas, G.O.; Croft, J.R.; Williams, M.K.; McHugh, J.O.

    1996-01-01

    Technologies that make use of ionising radiations are widespread. They provide many benefits but, as with other technologies, the use of ionising radiations carries with it the potential for incidents and accidents. Their severity can vary from the trivial to the fatal and may involve substantial economic penalties. In order to minimise the number of incidents and their consequences it is important that there is a mechanism to learn the lessons from those that do occur. To help pursue this objective the National Radiological Protection Board, the Health and Safety Executive and the Environment Agency have established a national Ionising Radiations Incident Database (IRID) to cover radiation incidents in industry, medicine, research and teaching. This publication details the specifications for IRID and its methods of operation. All information in the database will be unattributable and names of persons or organisations will not be included. It is a personal computer based system with 24 fields to categorise an incident, including a text field that will provide a description of the incident giving the causes, consequences, follow-up actions and lessons to be learned. These descriptions will be used in subsequent publications to provide feedback to the users. (UK)

  18. Fission ionisation chamber for the measurement of low fluxes of slow neutrons

    International Nuclear Information System (INIS)

    Weill, J.; Duchene, J.P.

    1958-01-01

    The ionisation chamber described is designed for the measurement of slow neutron fluxes of average or low intensity, in the presence, eventually, of very high gamma fluxes. The capture of a slow neutron by a fissile material, in this case 235 U, gives rise to fission fragments, high-energy particles which ionise the gas contained in the chamber. The neutrons are detected by virtue of the potential pulses, on the collecting electrode of the chamber, deriving from the collection of the ions produced by the fission fragments. The pulses are counted by means of a measuring system consisting of a preamplifier, a 2 Mc amplifier, a discriminator and an electronic scale with numerator or integrator. The general characteristics are as follows: sensitivity to neutrons: 0.07 kicks/n/cm 2 .s, sensitivity to γ rays: zero up to 3.10 4 R/H, a background noise at the normal discrimination voltage: 0.01 kicks/s, working H.T.: -500 V, capacity: 40 μμF, average height of pulse: 8 mV, limits of use: from several neutrons to 10 6 n/cm 2 .s. This chamber may be used in all cases where low fluxes of slow neutrons must be measured, especially in the presence of high gamma fluxes, for example in the checking of Pu concentrations in an extraction plant or for the starting up of reactors. (author) [fr

  19. The ionisation parameter of star-forming galaxies evolves with the specific star formation rate

    Science.gov (United States)

    Kaasinen, Melanie; Kewley, Lisa; Bian, Fuyan; Groves, Brent; Kashino, Daichi; Silverman, John; Kartaltepe, Jeyhan

    2018-04-01

    We investigate the evolution of the ionisation parameter of star-forming galaxies using a high-redshift (z ˜ 1.5) sample from the FMOS-COSMOS survey and matched low-redshift samples from the Sloan Digital Sky Survey. By constructing samples of low-redshift galaxies for which the stellar mass (M*), star formation rate (SFR) and specific star formation rate (sSFR) are matched to the high-redshift sample we remove the effects of an evolution in these properties. We also account for the effect of metallicity by jointly constraining the metallicity and ionisation parameter of each sample. We find an evolution in the ionisation parameter for main-sequence, star-forming galaxies and show that this evolution is driven by the evolution of sSFR. By analysing the matched samples as well as a larger sample of z physically consistent with the definition of the ionisation parameter, a measure of the hydrogen ionising photon flux relative to the number density of hydrogen atoms.

  20. Quantum coherence in photo-ionisation with tailored XUV pulses

    Science.gov (United States)

    Carlström, Stefanos; Mauritsson, Johan; Schafer, Kenneth J.; L'Huillier, Anne; Gisselbrecht, Mathieu

    2018-01-01

    Ionisation with ultrashort pulses in the extreme ultraviolet (XUV) regime can be used to prepare an ion in a superposition of spin-orbit substates. In this work, we study the coherence properties of such a superposition, created by ionising xenon atoms using two phase-locked XUV pulses at different frequencies. In general, if the duration of the driving pulse exceeds the quantum beat period, dephasing will occur. If however, the frequency difference of the two pulses matches the spin-orbit splitting, the coherence can be efficiently increased and dephasing does not occur.

  1. micro strip gas chamber

    CERN Multimedia

    1998-01-01

    About 16 000 Micro Strip Gas Chambers like this one will be used in the CMS tracking detector. They will measure the tracks of charged particles to a hundredth of a millimetre precision in the region near the collision point where the density of particles is very high. Each chamber is filled with a gas mixture of argon and dimethyl ether. Charged particles passing through ionise the gas, knocking out electrons which are collected on the aluminium strips visible under the microscope. Such detectors are being used in radiography. They give higher resolution imaging and reduce the required dose of radiation.

  2. Ionised Jets Associated With Massive Young Stellar Objects

    Science.gov (United States)

    Purser, Simon John Derek

    2017-09-01

    This thesis focuses on the phenomena of ionised jets associated with massive young stellar objects. Firstly a study was conducted with the aim to establish a statistical sample of such objects. Radio observations towards a sample of 49 MYSOs resulted in the detection of 28 objects classified as ionised jets. The jets’ radio luminosities scaled with their MYSOs’ bolometric luminosities in the same way as for low-mass examples. This infers that the jet launching and collimation mechanisms of high-mass jets are very similar to that in their low-mass counterparts and they are ejected for the last ≤65000 yr of the MYSO phase. Interestingly non-thermal emission was regularly detected towards spatially distinct radio lobes (associated with ˜50% of the jets), suggesting the presence of synchrotron emission and therefore, magnetic fields. With an average spectral index of ¯α=‑0. 55 (indicative of the 1st order Fermi acceleration mechanism) it is concluded these lobes are the result of shocks in the jets’ stream. My second science chapter is a study of radio variability, precession and proper motions towards a subset of objects from the first chapter. Over a two year time period, no significant variability and only one example of proper motion (1800±600 km s‑1) was detected. Precession was found to be commonplace however and if it arises as the result of binary interactions, we infer orbital radii between 30 and 1800 au for the binary companions. Lastly, high-resolution, VLA observations at C and Q-bands were analysed to extend the known sample of MYSOs harbouring ionised jets into the northern hemisphere. Only 3 radio sources were detected possessing jet-like characteristics towards the work’s sub-sample of 8 IRDCs containing 44 mm-cores (in our field of view), highlighting the radio-quiet (≳30μJy) nature of this early phase in massive star formation. Towards the RMS survey derived sample of 48 MYSOs, a total of 38 radio sources with jet

  3. Dose limits for ionising radiation

    International Nuclear Information System (INIS)

    Gifford, D.

    1989-01-01

    Dose limits for exposure to ionising radiation are assessed to see if they give sufficient protection both for the occupationally exposed and for the general public. It is concluded that current limits give a level of safety that satisfies the necessary criteria in the light of present knowledge and further reductions would be unlikely to improve standards of safety. (author)

  4. Flow lines and export lines of Sabalo Gas Field - the engineering of a complex job; Flow lines e export lines de Sabalo - a engenharia da complexidade

    Energy Technology Data Exchange (ETDEWEB)

    Serodio, Conrado Jose Morbach [GDK Engenharia, Salvador, BA (Brazil)

    2003-07-01

    The construction of the natural gas flow lines and export lines system of the Sabalo field, in the far South of Bolivia is an unique job in the pipeline construction area. Its execution is a turning point in terms of engineering and construction technology in this industry. Among the Aguarague Cordillera (mountains), it runs across rocky canyons for more than 5 km, a 2.100 mt long narrow tunnel to overcome the mountains and steep hills along all the ROW length, with a total extension of 70 km, in line pipes ranging from 10'' and 12'' for the flow lines, 28'' for the gas export line and 8' for the condensate line. An integrated construction work plan was settled in order to face and overcome the complex construction situations found in every feet of the pipeline. Four simultaneous work sites were mobilized, 8 independent work fronts, 700 professionals and more than 150 pieces of heavy construction equipment, brought from 3 different countries. Special techniques were adopted also to handle the challenging detail engineering . All in all, the correct conjunction of a sound engineering work, planning, human resources and equipment and the managing flexibility to create alternatives and solutions at the fast pace required by a dynamic work schedule were essential to succeed, in a job with no room for mistakes. The successfully job completion open new possibilities to other challenging projects alike.(author)

  5. An important step forward in continuous spectroscopic imaging of ionising radiations using ASICs

    Energy Technology Data Exchange (ETDEWEB)

    Fessler, P. [11 rue Rabelais, 92170 Vanves (France); Coffin, J. [Institut de Recherches Subatomiques, B.P. 28, 67037 Strasbourg (France); Eberle, H. [Institut de Recherches Subatomiques, B.P. 28, 67037 Strasbourg (France); Raad Iseli, C. de [Smart Silicon Systems SA, Ch. de la Graviere 6, CH-1007 Lausanne (Switzerland); Hilt, B. [Universite de Haute-Alsace, GRPHE, 61, rue Albert Camus, 68093 Mulhouse (France); Huss, D. [Universite de Haute-Alsace, GRPHE, 61, rue Albert Camus, 68093 Mulhouse (France); Krummenacher, F. [Smart Silicon Systems SA, Ch. de la Graviere 6, CH-1007 Lausanne (Switzerland); Lutz, J.R. [Institut de Recherches Subatomiques, B.P. 28, 67037 Strasbourg (France); Prevot, G. [Institut de Recherches Subatomiques, B.P. 28, 67037 Strasbourg (France); Renouprez, A. [Institut de Recherche sur la Catalyse, 2 Avenue Albert Einstein, 69626 Villeurbanne (France); Sigward, M.H. [Institut de Recherches Subatomiques, B.P. 28, 67037 Strasbourg (France); Schwaller, B. [Universite de Haute-Alsace, GRPHE, 61, rue Albert Camus, 68093 Mulhouse (France); Voltolini, C. [Institut de Recherches Subatomiques, B.P. 28, 67037 Strasbourg (France)

    1999-01-21

    Characterization results are given for an original ASIC allowing continuous acquisition of ionising radiation images in spectroscopic mode. Ionising radiation imaging in general and spectroscopic imaging in particular must primarily be guided by the attempt to decrease statistical noise, which requires detection systems designed to allow very high counting rates. Any source of dead time must therefore be avoided. Thus, the use of on-line corrections of the inevitable dispersion of characteristics between the large number of electronic channels of the detection system, shall be precluded. Without claiming to achieve ultimate noise levels, the work described is focused on how to prevent good individual acquisition channel noise performance from being totally destroyed by the dispersion between channels without introducing dead times. With this goal, we developed an automatic charge amplifier output voltage offset compensation system which operates regardless of the cause of the offset (detector or electronic). The main performances of the system are the following: the input equivalent noise charge is 190 e rms (input non connected, peaking time 500 ns), the highest gain is 255 mV/fC, the peaking time is adjustable between 200 ns and 2 {mu}s and the power consumption is 10 mW per channel. The agreement between experimental data and theoretical simulation results is excellent.

  6. An important step forward in continuous spectroscopic imaging of ionising radiations using ASICs

    International Nuclear Information System (INIS)

    Fessler, P.; Coffin, J.; Eberle, H.; Raad Iseli, C. de; Hilt, B.; Huss, D.; Krummenacher, F.; Lutz, J.R.; Prevot, G.; Renouprez, A.; Sigward, M.H.; Schwaller, B.; Voltolini, C.

    1999-01-01

    Characterization results are given for an original ASIC allowing continuous acquisition of ionising radiation images in spectroscopic mode. Ionising radiation imaging in general and spectroscopic imaging in particular must primarily be guided by the attempt to decrease statistical noise, which requires detection systems designed to allow very high counting rates. Any source of dead time must therefore be avoided. Thus, the use of on-line corrections of the inevitable dispersion of characteristics between the large number of electronic channels of the detection system, shall be precluded. Without claiming to achieve ultimate noise levels, the work described is focused on how to prevent good individual acquisition channel noise performance from being totally destroyed by the dispersion between channels without introducing dead times. With this goal, we developed an automatic charge amplifier output voltage offset compensation system which operates regardless of the cause of the offset (detector or electronic). The main performances of the system are the following: the input equivalent noise charge is 190 e rms (input non connected, peaking time 500 ns), the highest gain is 255 mV/fC, the peaking time is adjustable between 200 ns and 2 μs and the power consumption is 10 mW per channel. The agreement between experimental data and theoretical simulation results is excellent

  7. On-line gas mixing and multi-channel distribution system

    International Nuclear Information System (INIS)

    Kalmani, S.D.; Mondal, N.K.; Satyanarayana, B.; Verma, P.; Joshi, Avinash

    2009-01-01

    In this presentation, we describe a mass-flow controller based on-line gas mixing unit with the multi-channel distribution system. We highlight different aspects such as requirement, design, calibration, control and operation of this system. This unit has the capability to mix up to four different input gases and distribute over 16 output channels. Output in individual channels is controlled accurately by using capillary-based system. At present, we are using this gas mixing unit for prototype of iron calorimeter (ICAL) detector of India-based Neutrino Observatory (INO).

  8. Characterisation of bacteria by matrix-assisted laser desorption/ionisation and electrospray mass spectrometry

    NARCIS (Netherlands)

    Baar, B.L.M. van

    2000-01-01

    Chemical analysis for the characterisation of micro-organisms is rapidly evolving, after the recent advent of new ionisation methods in mass spectrometry (MS): electrospray (ES) and matrix-assisted laser desorption/ionisation (MALDI). These methods allow quick characterisation of micro-organisms,

  9. Natural gas large volumes measurement: going for on-line custody transfer; Medicao de grandes volumes de gas natural: rumo a transferencia de custodia on-line

    Energy Technology Data Exchange (ETDEWEB)

    Mercon, Eduardo G.; Frisoli, Caetano [PETROBRAS Transporte S.A. (TRANSPETRO), Rio de Janeiro, RJ (Brazil)

    2005-07-01

    This paper describes the structure of the natural gas flow measurement process in TRANSPETRO, and comments features and performance of existing or under-implantation equipment and systems, reviewing best practices and technology in use. This process runs through three interrelated segments: data flow measurement, strictly speaking; data transfer and acquisition; and data flow measurement certification (data consolidation to invoice). Initially, the work makes an approach to the data flow measurement segment, evaluating technical features of flow meters, and describing configurations and functions of the operating gas flow computers in TRANSPETRO's custody transfer stations. In this part it will also be presented the implantation of TRANSPETRO's system for gas chromatography data input on-line to flow computers. Further, in data transfer and acquisition, SCADA system technical aspects will be evaluated, considering communications protocols and programmable logic controllers functions in remote terminal units, and discussing their places in the measurement process. Additionally, TRANSPETRO's experience in data measurement certification tools is in discussion, as well as new upcoming tools and their potential features, from what new practices will be suggested. Finally, all the work has been conceived and carried out always aiming to the state-of-the-art technology in gas flow measurement: on-line custody transfer. (author)

  10. Diagnostics of red-shifted H-alpha line emission from a C-class flare with full non-LTE radiative and hydrodynamic approach

    Science.gov (United States)

    Druett, M. K.; Zharkova, V. V.; Scullion, E.; Zharkov, S.; Matthews, S. A.

    2016-12-01

    We analyse H-alpha line profiles with strong redshifts during the C1.8 flare on 1st July 2012 obtained from the Swedish Solar Telescope (SST) closely resembling the previous observations (Wuelser and Marti, 1989). The flare has a magnetic field configuration with two levels of loop structures. The kernels with red shifts are observed in one of the H-alpha ribbons in the south-west location formed after the main impulse recorded in the north-east. The locations of H-alpha kernels with red shifts reveal close temporal and spatial correlation with weaker HXR signatures and coincide with the locations of coronal jets observed with AIA/SDO. For interpretation we apply a revised 1D hydrodynamic and non-LTE (NLTE) radiative model for 5 level plus continuum model hydrogen atom (Druett & Zharkova, 2016) considering radiative, thermal and non-thermal excitation and ionisation by beam electrons with the updated beam densities (Zharkova & Dobranskis, 2016) and analytical excitation/ionisation rates (Zharkova& Kobylinskijj, 1993). We find the simultaneous solutions of steady state and radiative transfer equations in all optically-thick lines and continua. The electron and ion temperatures, ambient density and macrovelocity of the ambient plasma are derived from a 1D hydrodynamic model with initial condition of the pre-flaring photosphere for the two fluid ambient plasma heated by beam electrons (Zharkova & Zharkov, 2007). We simulate distributions over precipitation depth of ionisation and departure coefficients for all the hydrogen atom transitions including the deviation of ionisation from Saha equation affected by non-thermal electron beams. We show that in the very first seconds after the beam onset Balmer line profiles are sensitive to the effect of beam electrons. The combination of the additional ionisation caused by beam electrons leading to a very strong Stark effect in Balmer lines with the hydrodynamic heating and formation of a low temperature shock in the

  11. Advisory group on ionising radiation

    International Nuclear Information System (INIS)

    Harrison, J.R.

    1996-01-01

    The Advisory Group on Ionising Radiation has a busy and challenging work programme. Its reports will be published in the Documents of the NRPB series. These may advise further research or could form the basis of formal NRPB advice. Covering the full spectrum of radiation issues at work, in public health and clinical medicine, and the environment, it should enhance the radiation advice available to NRPB. (author)

  12. Intercomparison of radon gas detectors 1999 and 2000 at PSI

    International Nuclear Information System (INIS)

    Schuler, Christoph; Butterweck, Gernot

    2000-10-01

    This report describes the results of two radon intercomparison exercises performed by the Reference Laboratory for Radon Gas Activity Concentration Measurements at Paul Scherrer Institut from Sep 9th to Oct 6th, 1999, and from March 21st to 28th, 2000. Radon gas detectors and instruments were exposed in the PSI Radon Chamber in reference atmospheres to 1060 kBqhm -3 radon gas exposure at an average radon gas concentration of 6400 Bqm -3 and to 2050 kBqhm -3 radon gas exposure at an average radon gas concentration of 12500 Bqm -3 , respectively. These intercomparison exercises determined the performance of electret ionisation chambers, track etch detectors and measuring instruments at high humidity (1999 Intercomparison Exercise) and at a high radon gas exposure (2000 Intercomparison Exercise). In the 1999 Intercomparison Exercise, electret ionisation chambers revealed an influence on high humidity. This effect may be due to impurities on a microscopic scale on the electrets of these detectors. With few exceptions, in both the 1999 and the 2000 Radon Intercomparison Exercise the deviations of the measurement results to the reference radon gas concentration values were less than 15% (traceability criterion) and the standard deviation of the results of five detectors less than 15% (reproducibility criterion). (author) [de

  13. Formation rate of ammonium nitrate in the off-gas line of SRAT and SME in DWPF

    International Nuclear Information System (INIS)

    Lee, L.

    1992-01-01

    A mathematical model for the formation rate of ammonium nitrate in the off-gas line of the Sludge Receipt and Adjustment Tank (SRAT) and the Slurry Mixed Evaporator (SME) in DWPF has been developed. The formation rate of ammonium nitrate in the off-gas line depends on pH, temperature, volume and total concentration of ammonia and ammonium ion. Based on a typical SRAT and SME cycle in DWPF, this model predicts the SRAT contributes about 50 lbs of ammonium nitrate while SME contributes about 60 lbs of ammonium nitrate to the off-gas line

  14. Penning transfer in argon-based gas mixtures

    CERN Document Server

    Sahin, O; Tapan, I; Ozmutlu, E N

    2010-01-01

    Penning transfers, a group of processes by which excitation energy is used to ionise the gas, increase the gas gain in some detectors. Both the probability that such transfers occur and the mechanism by which the transfer takes place, vary with the gas composition and pressure. With a view to developing a microscopic electron transport model that takes Penning transfers into account, we use this dependence to identify the transfer mechanisms at play. We do this for a number of argon-based gas mixtures, using gain curves from the literature.

  15. Proceedings. Protection of the natural environment. International symposium on ionising radiation

    International Nuclear Information System (INIS)

    Amiro, B.; Johansson, Gunnar; Larsson, Carl-Magnus; Luening, M.

    1996-01-01

    The symposium was organised jointly by the Swedish Radiation Protection Institute and the Atomic Energy Control Board of Canada. The programme was organised around six major topics: Biological effects of ionising radiation; Ecological effects of ionising radiation; Behaviour and transport of radionuclides in the natural environment; Criteria for environmental protection; Assessment methodology; and Social and economic aspects. All 86 contributions (excluding the opening addresses) have been separately indexed

  16. An X-Ray/SDSS Sample: Observational Characterization of The Outflowing Gas

    Science.gov (United States)

    Perna, Michele; Brusa, M.; Lanzuisi, G.; Mignoli, M.

    2016-10-01

    Powerful ionised AGN-driven outflows, commonly detected both locally and at high redshift, are invoked to contribute to the co-evolution of SMBH and galaxies through feedback phenomena. Our recent works (Brusa+2015; 2016; Perna+2015a,b) have shown that the XMM-COSMOS targets with evidence of outflows collected so far ( 10 sources) appear to be associated with low X-ray kbol corrections (Lbol /LX ˜ 18), in spite of their spread in obscuration, in the locations on the SFR-Mstar diagram, in their radio emission. A higher statistical significance is required to validate a connection between outflow phenomena and a X-ray loudness. Moreover, in order to validate their binding nature to the galaxy fate, it is crucial to correctly determine the outflow energetics. This requires time consuming integral field spectroscopic (IFS) observations, which are, at present, mostly limited to high luminosity objectsThe study of SDSS data offers a complementary strategy to IFS efforts. I will present physical and demographic characterization of the AGN-galaxy system during the feedback phase obtained studying a sample of 500 X-ray/SDSS AGNs, at zdispersion) and X-ray properties (intrinsic X-ray luminosity, obscuration and X-ray kbol correction), to determine what drives ionised winds. Several diagnostic line ratios have been used to infer the physical properties of the ionised outflowing gas. The knowledge of these properties can reduce the actual uncertainties in the outflow energetics by a factor of ten, pointing to improve our understanding of the AGN outflow phenomenon and its impact on galaxy evolution.

  17. Ionisation of hydrogen-like atoms by a multiphoton absorption process

    International Nuclear Information System (INIS)

    Gontier, Y.; Trahin, M.

    1967-01-01

    The general expression for the amplitude of the probability of ionisation by a multiphoton absorption process is derived. Its non-relativistic limit is taken and the bipolar approximation is used for calculating the ionisation cross-section of hydrogen-like atoms. This latter involves the summation over intermediate virtual states by means of: a) a recursion relationship concerning angular functions, b) a particular technique which when applied to radial functions makes it possible to solve a system of inhomogeneous first-order differential equations. (authors) [fr

  18. Influence of easily ionised elements on the delayed responses of the emission intensities of an analyte in a power modulated U-shaped argon stabilised DC arc plasma with an aerosol supply

    Directory of Open Access Journals (Sweden)

    MIROSLAV KUZMANOVIC

    2005-09-01

    Full Text Available The current of a U-shaped argon stabilised DC arc was square modulated with a 40 Hz repetition frequency between 6 and 3 A. The delayed line intensity responses to the modulation of the arc current were investigated using calcium as a representative analyte. The intensities of both the atomic and ionic lines were monitored at different distances from the arc axis in the presence of various concentrations of the easily ionised element. Temporal evolutions were monitored on a millisecond time scale. It was found that the responses of the line intesity to the arc current change strongly depended on the observed radial position, especially in the vicinity of the arc axis. The obtained results showed a significant influence of even small amounts of the easily ionised element on the excitation and transport of the analyte and indicated a way of possibly improving the analytical capabilities of the excitation source.

  19. Extra holiday because of ionising radiation not necessary

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    The 'regulations for special measures to protect employees working with X-rays and radium radiation' of 21st November 1947, which included a statutory six-week holiday period annually, has now been superceded by 'regulations on special protective measures for work with ionising radiation', issued by the Directorate for Work Inspection on 31st March 1978, effective from 1st May 1978. In addition to removing the requirement for six weeks annual holiday for radiation personnel, routine medical surveillance is only required every third year instead of annually. A number of other changes are mentioned. The basis for these changes is that continuous personnel dosimetry and better knowledge of the effects of ionising radiation allows any necessary measures to be taken on the basis of these. (JIW)

  20. ACOUSTIC DETECTING AND LOCATING GAS PIPE LINE INFRINGEMENT

    Energy Technology Data Exchange (ETDEWEB)

    John L. Loth; Gary J. Morris; George M. Palmer; Richard Guiler; Patrick Browning

    2004-10-31

    The extensive network of high-pressure natural gas transmission pipelines covering the United States provides an important infrastructure for our energy independence. Early detection of pipeline leaks and infringements by construction equipment, resulting in corrosion fractures, presents an important aspect of our national security policy. The National Energy Technology Laboratory Strategic Center for Natural Gas (SCVG) is and has been funding research on various applicable techniques. The WVU research team has focused on monitoring pipeline background acoustic signals generated and transmitted by gas flowing through the gas inside the pipeline. In case of a pipeline infringement, any mechanical impact on the pipe wall, or escape of high-pressure gas, generates acoustic signals traveling both up and down stream through the gas. Sudden changes in flow noise are detectable with a Portable Acoustic Monitoring Package (PAMP), developed under this contract. It incorporates a pressure compensating microphone and a signal- recording device. Direct access to the gas inside the line is obtained by mounting such a PAMP, with a 1/2 inch NPT connection, to a pipeline pressure port found near most shut-off valves. An FFT of the recorded signal subtracted by that of the background noise recorded one-second earlier appears to sufficiently isolate the infringement signal to allow source interpretation. Using cell phones for data downloading might allow a network of such 1000-psi rated PAMP's to acoustically monitor a pipeline system and be trained by neural network software to positively identify and locate any pipeline infringement.

  1. ACOUSTIC DETECTING AND LOCATING GAS PIPE LINE INFRINGEMENT

    Energy Technology Data Exchange (ETDEWEB)

    John L. Loth; Gary J. Morris; George M. Palmer; Richard Guiler; Patrick Browning

    2004-12-01

    The extensive network of high-pressure natural gas transmission pipelines covering the United States provides an important infrastructure for our energy independence. Early detection of pipeline leaks and infringements by construction equipment, resulting in corrosion fractures, presents an important aspect of our national security policy. The National Energy Technology Laboratory Strategic Center for Natural Gas (SCVG) is and has been funding research on various applicable techniques. The WVU research team has focused on monitoring pipeline background acoustic signals generated and transmitted by gas flowing through the gas inside the pipeline. In case of a pipeline infringement, any mechanical impact on the pipe wall, or escape of high-pressure gas, generates acoustic signals traveling both up and down stream through the gas. Sudden changes in flow noise are detectable with a Portable Acoustic Monitoring Package (PAMP), developed under this contract. It incorporates a pressure compensating microphone and a signal- recording device. Direct access to the gas inside the line is obtained by mounting such a PAMP, with a 1/2 inch NPT connection, to a pipeline pressure port found near most shut-off valves. An FFT of the recorded signal subtracted by that of the background noise recorded one-second earlier appears to sufficiently isolate the infringement signal to allow source interpretation. Using cell phones for data downloading might allow a network of such 1000-psi rated PAMP's to acoustically monitor a pipeline system and be trained by neural network software to positively identify and locate any pipeline infringement.

  2. Food preservation by ionising radiation

    International Nuclear Information System (INIS)

    Andrade, M. E.

    1996-01-01

    The process of food preservation by ionising radiation is an alternative, or a complement, to the traditional methods of heating, refrigerating, freezing or using chemical additives. The study and development of this technique has started on the beginning of the fifties but it is based on the radiation killing effect on micro-organisms discovered by the end of last century. Foodstuffs are treated in appropriate plants: isotopic facilities (gamma radiation) and accelerated electron beams produced by machines called accelerators. The FAO and WHO in close cooperation with the IAEA have played an important role on the development of the process and on the increment of the industrial application of food irradiation. Over the world there are about 37 countries trading foods treated by ionising radiation. However, governments have been slow to clear the utilization of this process. The main reason of this attitude is in general due to the fact that the advantages of the technique are not clearly understood. Therefore, the dissemination of the information could on one hand clarify who has to take decisions and on the other hand support the choice of those foods by the consumers. This is the unique way to dynamize the application of this process

  3. How do air ions reflect variations in ionising radiation in the lower atmosphere in a boreal forest?

    Directory of Open Access Journals (Sweden)

    X. Chen

    2016-11-01

    Full Text Available Most of the ion production in the atmosphere is attributed to ionising radiation. In the lower atmosphere, ionising radiation consists mainly of the decay emissions of radon and its progeny, gamma radiation of the terrestrial origin as well as photons and elementary particles of cosmic radiation. These types of radiation produce ion pairs via the ionisation of nitrogen and oxygen as well as trace species in the atmosphere, the rate of which is defined as the ionising capacity. Larger air ions are produced out of the initial charge carriers by processes such as clustering or attachment to pre-existing aerosol particles. This study aimed (1 to identify the key factors responsible for the variability in ionising radiation and in the observed air ion concentrations, (2 to reveal the linkage between them and (3 to provide an in-depth analysis into the effects of ionising radiation on air ion formation, based on measurement data collected during 2003–2006 from a boreal forest site in southern Finland. In general, gamma radiation dominated the ion production in the lower atmosphere. Variations in the ionising capacity came from mixing layer dynamics, soil type and moisture content, meteorological conditions, long-distance transportation, snow cover attenuation and precipitation. Slightly similar diurnal patterns to variations in the ionising capacity were observed in air ion concentrations of the cluster size (0.8–1.7 nm in mobility diameters. However, features observed in the 0.8–1 nm ion concentration were in good connection to variations of the ionising capacity. Further, by carefully constraining perturbing variables, a strong dependency of the cluster ion concentration on the ionising capacity was identified, proving the functionality of ionising radiation in air ion production in the lower atmosphere. This relationship, however, was only clearly observed on new particle formation (NPF days, possibly indicating that charges after

  4. Possibility of gas flow measurements using ionization produced by radioactive sources. Performance obtained using continuous and pulsed ionization; Etude des possibilites de mesure des debits gazeux par l'ionisation creee au moyen de sources radioactives performances obtenues par ionisation continue et par ionisation pulsee

    Energy Technology Data Exchange (ETDEWEB)

    Toudoire, B. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    Two methods for measuring gas flow have been studied, based on the ionization of the fluid by a radioactive source. In the first one, called the continuous method, use is made of the relationship between the flow and the ionic density at a point situated down-stream from the ionizing source. In the second method, called 'pulsed', the time for a burst of ions to pass between two points in the circuit is measured. An attempt has been made to predict and to justify theoretically the experimental results, and to determine to what extent these methods can provide absolute measurements or measurements requiring a calibration using known gas flows. These methods are characterized by the absence of moving parts or of parts under reduced pressure and can yield results with an accuracy of between a few per cent to a few tenths of a per cent. The information, provided in either analog or digital form, can be adapted for use in servo-mechanisms or automatic systems. Two applications of an industrial type are described; they concern gas-flow measurements in a railway braking circuit, and in tubes of 20 and 30 cm diameter. (author) [French] Deux methodes de mesure de debit gazeux ont ete etudiees, basees sur l'ionisation du fluide par une source radioactive. Dans la premiere, dite continue, on exploite la relation existant entre le debit et la densite ionique en un point situe a l'aval de la source ionisante. Dans la seconde, dite pulsee, on mesure le temps de transit de bouffees d'ions entre deux points de la conduite. On s'est efforce de prevoir et de justifier par la theorie les resultats experimentaux, et de preciser dans quelle mesure ces methodes peuvent fournir des mesures absolues ou necessitent un etalonnage a partir de debits connus. Caracterisees par l'absence d'organe mobile ou deprimogene, ces methodes sont susceptibles d'une precision de quelques pour-cent a quelques pour-mille. L'information, fournie sous forme

  5. Possibility of gas flow measurements using ionization produced by radioactive sources. Performance obtained using continuous and pulsed ionization; Etude des possibilites de mesure des debits gazeux par l'ionisation creee au moyen de sources radioactives performances obtenues par ionisation continue et par ionisation pulsee

    Energy Technology Data Exchange (ETDEWEB)

    Toudoire, B [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    Two methods for measuring gas flow have been studied, based on the ionization of the fluid by a radioactive source. In the first one, called the continuous method, use is made of the relationship between the flow and the ionic density at a point situated down-stream from the ionizing source. In the second method, called 'pulsed', the time for a burst of ions to pass between two points in the circuit is measured. An attempt has been made to predict and to justify theoretically the experimental results, and to determine to what extent these methods can provide absolute measurements or measurements requiring a calibration using known gas flows. These methods are characterized by the absence of moving parts or of parts under reduced pressure and can yield results with an accuracy of between a few per cent to a few tenths of a per cent. The information, provided in either analog or digital form, can be adapted for use in servo-mechanisms or automatic systems. Two applications of an industrial type are described; they concern gas-flow measurements in a railway braking circuit, and in tubes of 20 and 30 cm diameter. (author) [French] Deux methodes de mesure de debit gazeux ont ete etudiees, basees sur l'ionisation du fluide par une source radioactive. Dans la premiere, dite continue, on exploite la relation existant entre le debit et la densite ionique en un point situe a l'aval de la source ionisante. Dans la seconde, dite pulsee, on mesure le temps de transit de bouffees d'ions entre deux points de la conduite. On s'est efforce de prevoir et de justifier par la theorie les resultats experimentaux, et de preciser dans quelle mesure ces methodes peuvent fournir des mesures absolues ou necessitent un etalonnage a partir de debits connus. Caracterisees par l'absence d'organe mobile ou deprimogene, ces methodes sont susceptibles d'une precision de quelques pour-cent a quelques pour-mille. L'information, fournie sous forme analogique ou numerique, se prete a la realisation de

  6. Recent trends in utilising ionising radiations for nondestructive evaluation of materials (Preprint No. SP-3)

    International Nuclear Information System (INIS)

    Raj, Baldev; Venkatraman, B.

    1988-02-01

    The various NDT techniques based on the use of ionising radiations can be broadly classified into radiography, radiation gaging techniques and analytical techniques. This paper highlights the state of art of these techniques along with their applications. While an effort has been made to cover the major techniques based on ionising radiations, many techniques utilising ionising radiations as xeroradiography, laminography, ionography etc, have not been dealt with due to their restricted applications. (author). 23 refs., 4 figs

  7. Gas injected washer plasma gun

    International Nuclear Information System (INIS)

    Jain, K.K.; John, P.I.; Punithavelu, A.M.; Rao, P.P.

    1980-01-01

    A plasma gun similar in geometry to the washer plasma gun has been operated with gas injected externally. hydrogen, nitrogen and argon plasmas have been ionised and accelerated to velocities of the order of 10 7 mm s -1 and densities 10 11 mm -3 . Higher parameter range is possible with higher electrical input power. (author)

  8. The potential use of ionising energy treatment in Queensland's horticultural industries

    International Nuclear Information System (INIS)

    Heather, N.W.; Sheehy, P.T.; Muirhead, I.F.; Brown, B.I.; Hassall, R.N.

    1985-01-01

    The potential application of ionising energy treatment technology in Queensland falls into three categories: insect disinfestation, disease control and quality improvement. The technology fulfils the requirements of a disinfestation treatment against Queensland fruit fly and other pests of quarantine importance in respect to efficacy, absence of phytotoxicity, absence of residues and, on technical considerations would be an ideal replacement for the fumigant EDB. The report examines the purposes of ionising energy treatment, economic and marketing aspects and research needs

  9. Ionising radiation risk disclosure: When should radiographers assume a duty to inform?

    Science.gov (United States)

    Younger, C W E; Douglas, C; Warren-Forward, H

    2018-05-01

    Autonomy is a fundamental patient right for ethical practice, and informed consent is the mechanism by which health care professionals ensure this right has been respected. The ethical notion of informed consent has evolved alongside legal developments. Under Australian law, a provider who fails to disclose risk may be found to be in breach of a duty of disclosure, potentially facing legal consequences if the patient experiences harm that is attributable to an undisclosed risk. These consequences may include the common law tort of negligence. Ionising radiation, in the form of a medical imaging examination, has the potential to cause harm. However, stochastic effects cannot be attributable to a specific ionising radiation event. What then is the role of the Australian medical imaging service provider in disclosing ionising radiation risk? The ethical and legal principles of informed consent, and the duty of information provision to the patient are investigated. These general principles are then applied to the specific and unusual case of ionising radiation, and what responsibilities apply to the medical imaging provider. Finally, the legal, professional and ethical duties of the radiographer to disclose information to their patients are investigated. Australian law is unclear as to whether a radiographer has a common law responsibility to disclose radiation risk. There is ambiguity as to whether stochastic ionising radiation risk could be considered a legal disclosure responsibility. While it is unlikely that not disclosing risk will have medicolegal consequences, doing so represents sound ethical practice. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  10. Gas breakdown in tokamaks

    International Nuclear Information System (INIS)

    Abramov, V.A.; Pogutse, O.P.; Yurchenko, Eh.I.

    1975-01-01

    The initial stage of the charge development in a tokomak is considered theoretically. It is supposed that all electrons produced in neutral gas ionisation process are in the regime of an almost continuous acceleration. The production time of a given electron density is calculated as a function of the neutral gas density and of parameters of the vortex electric field. The mechanism of plasma escape on walls is considered. It is shown that the escaping time is defined by a specific inertial flow of plasma and depends on whether chamber walls are metal or dielectric. The criterion of the gas breakdown in a toroidal system is formulated. The developed theory is shown to explain a strong dependence of the breakdown on the gas initial density [ru

  11. Measurement Of Ultrafast Ionisation From Intense Laser Interactions With Gas-Jets

    International Nuclear Information System (INIS)

    Gizzi, Leonida A.; Galimberti, Marco; Giulietti, Antonio; Giulietti, Danilo; Koester, Petra; Labate, Luca; Tomassini, Paolo; Martin, Philippe; Ceccotti, Tiberio; De Oliveira, Pascal; Monot, Pascal

    2006-01-01

    Interaction of an intense, ultrashort laser pulse with a gas-jet target is investigated through femtosecond optical interferometry to study the dynamics of ionization of the gas. Experimental results are presented in which the propagation of the pulse in the gas and the consequent plasma formation is followed step by step with high temporal and spatial resolution. We demonstrate that, combining the phase shift with the measurable depletion of fringe visibility associated with the transient change of refractive index in the ionizing region and taking into account probe travel time can provide direct information on gas ionization dynamics

  12. Contact line motion in confined liquid–gas systems: Slip versus phase transition

    KAUST Repository

    Xu, Xinpeng

    2010-11-30

    In two-phase flows, the interface intervening between the two fluid phases intersects the solid wall at the contact line. A classical problem in continuum fluid mechanics is the incompatibility between the moving contact line and the no-slip boundary condition, as the latter leads to a nonintegrable stress singularity. Recently, various diffuse-interface models have been proposed to explain the contact line motion using mechanisms missing from the sharp-interface treatments in fluid mechanics. In one-component two-phase (liquid–gas) systems, the contact line can move through the mass transport across the interface while in two-component (binary) fluids, the contact line can move through diffusive transport across the interface. While these mechanisms alone suffice to remove the stress singularity, the role of fluid slip at solid surface needs to be taken into account as well. In this paper, we apply the diffuse-interface modeling to the study of contact line motion in one-component liquid–gas systems, with the fluid slip fully taken into account. The dynamic van der Waals theory has been presented for one-component fluids, capable of describing the two-phase hydrodynamics involving the liquid–gas transition [A. Onuki, Phys. Rev. E 75, 036304 (2007)]. This theory assumes the local equilibrium condition at the solid surface for density and also the no-slip boundary condition for velocity. We use its hydrodynamicequations to describe the continuum hydrodynamics in the bulk region and derive the more general boundary conditions by introducing additional dissipative processes at the fluid–solid interface. The positive definiteness of entropy production rate is the guiding principle of our derivation. Numerical simulations based on a finite-difference algorithm have been carried out to investigate the dynamic effects of the newly derived boundary conditions, showing that the contact line can move through both phase transition and slip, with their relative

  13. Ionising radiation safety training in the Australian Defence Organisation (ADO)

    International Nuclear Information System (INIS)

    Jenks, G.J.; O'Donovan, E.J.B.; Wood, W.B.

    1998-01-01

    Training personnel in ionising radiation safety within the Australian Defence Organisation (ADO) requires addressing some unique features of an organisation employing both military and civilian personnel. Activities may include those of a civil nature (such as industrial and medical radiography), specific military requirements (for training and emergency response) and scientific research and development. Some personnel may be assigned to full-time duties associated with radiation. However, most are designated as radiation protection officers as a secondary duty. A further complication is that most military personnel are subjected to postings at regular intervals. The ADO's Directorate of Defence Occupational Health and Safety has established an Ionising Radiation Safety Subcommittee to monitor not only the adequacy of the internal Ionising Radiation Safety Manual but also the training requirements. A Training Course, responding to these requirements, has been developed to emphasize, basic radiation theory and protection, operation of radiation monitors available in the ADO, an understanding of the Ionising Radiation Safety Manual, day-to-day radiation safety in units and establishments, and appropriate responses to radiation accidents and emergencies. In addition, students are briefed on a limited number of peripheral topics and participate in some site visits. Currently, two Courses are held annually, each with about twenty students. Most of the material is presented by ADO personnel with external contractor support. The three Courses held to date have proved successful, both for the students and the ADO generally. To seek national accreditation of the course through the Australian National Training Authority, as a first step, competency standards have been proposed. (authors)

  14. Health protection of persons occupationally exposed to ionising radiation in Croatia

    International Nuclear Information System (INIS)

    Zavalic, M.

    2005-01-01

    The aim of this study was to investigate the health condition of workers occupationally exposed to ionising radiation. The results for 1406 workers exposed to ionising radiations, who were regularly examined in 2004, were analysed using Statistica 5.0. The analysis included workers' case histories, frequency of illnesses and causes of temporary or permanent work disability. Of 1406 workers, 16 (1.13%) were found permanently disabled; in 11 the cause of disability was lens opacity, in 2 persistent trombocitophenia, and in 2 malignant tumour. Twenty-four workers were temporarily disabled, of whom 5 due to pregnancy. Thrombocytopenia was found in 12 men and only one woman. Anaemia was found in 4 women; dicentric chromosomes were the cause of temporary disability in one person, and tuberculosis in one person. Medical examinations of Croatian workers confirm low occupational exposure to ionising radiation. With this type of radiation, the established lens impairments could not be characterised as occupational. The two malignant tumours however were recognised as occupational diseases.(author)

  15. Erich Regener and the ionisation maximum of the atmosphere

    Science.gov (United States)

    Carlson, P.; Watson, A. A.

    2014-12-01

    In the 1930s the German physicist Erich Regener (1881-1955) did important work on the measurement of the rate of production of ionisation deep under water and in the atmosphere. Along with one of his students, Georg Pfotzer, he discovered the altitude at which the production of ionisation in the atmosphere reaches a maximum, often, but misleadingly, called the Pfotzer maximum. Regener was one of the first to estimate the energy density of cosmic rays, an estimate that was used by Baade and Zwicky to bolster their postulate that supernovae might be their source. Yet Regener's name is less recognised by present-day cosmic ray physicists than it should be, largely because in 1937 he was forced to take early retirement by the National Socialists as his wife had Jewish ancestors. In this paper we briefly review his work on cosmic rays and recommend an alternative naming of the ionisation maximum. The influence that Regener had on the field through his son, his son-in-law, his grandsons and his students, and through his links with Rutherford's group in Cambridge, is discussed in an appendix. Regener was nominated for the Nobel Prize in Physics by Schrödinger in 1938. He died in 1955 at the age of 73.

  16. Fission ionisation chamber for the measurement of low fluxes of slow neutrons; Chambre d'ionisation a fission pour la mesure des faibles flux de neutrons lents

    Energy Technology Data Exchange (ETDEWEB)

    Weill, J; Duchene, J P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    The ionisation chamber described is designed for the measurement of slow neutron fluxes of average or low intensity, in the presence, eventually, of very high gamma fluxes. The capture of a slow neutron by a fissile material, in this case {sup 235}U, gives rise to fission fragments, high-energy particles which ionise the gas contained in the chamber. The neutrons are detected by virtue of the potential pulses, on the collecting electrode of the chamber, deriving from the collection of the ions produced by the fission fragments. The pulses are counted by means of a measuring system consisting of a preamplifier, a 2 Mc amplifier, a discriminator and an electronic scale with numerator or integrator. The general characteristics are as follows: sensitivity to neutrons: 0.07 kicks/n/cm{sup 2}.s, sensitivity to {gamma} rays: zero up to 3.10{sup 4} R/H, a background noise at the normal discrimination voltage: 0.01 kicks/s, working H.T.: -500 V, capacity: 40 {mu}{mu}F, average height of pulse: 8 mV, limits of use: from several neutrons to 10{sup 6} n/cm{sup 2}.s. This chamber may be used in all cases where low fluxes of slow neutrons must be measured, especially in the presence of high gamma fluxes, for example in the checking of Pu concentrations in an extraction plant or for the starting up of reactors. (author) [French] La chambre d'ionisation decrite est destinee a la mesure des flux de neutrons lents d'intensite moyenne ou faible, en presence eventuelle de flux gamma tres importants. La capture d'un neutron lent par un materiau fissile, en l'occurrence {sup 235}U, donne naissance a des fragments de fission, particules de grande energie qui ionisent le gaz contenu dans la chambre. Les neutrons sont detectes grace aux impulsions de potentiel, sur l'electrode collectrice de la chambre, provenant de la collection des ions produits par les fragments de fission. Une chaine de mesure comprenant un preamplificateur, un amplificateur 2 Mc, un discriminateur, une echelle

  17. The potential of organic (electrospray- and atmospheric pressure chemical ionisation) mass spectrometric techniques coupled to liquid-phase separation for speciation analysis.

    Science.gov (United States)

    Rosenberg, Erwin

    2003-06-06

    environment, health and food. Particular attention is given to the characterisation of biomolecules and metalloproteins (metallothioneins and phytochelatins) and to the investigation of the interaction of metals and biomolecules. Particularly in the latter field, ESI-MS is the ideal technique due to the softness of the ionisation process which allows to assume that the detected gas-phase ions are a true representation of the ions or ion-biomolecule complexes prevalent in solution. It is particularly this field, important to biochemistry, physiology and medical chemistry, where we can expect significant developments also in the future.

  18. Properties of an ionised-cluster beam from a vaporised-cluster ion source

    International Nuclear Information System (INIS)

    Takagi, T.; Yamada, I.; Sasaki, A.

    1978-01-01

    A new type of ion source vaporised-metal cluster ion source, has been developed for deposition and epitaxy. A cluster consisting of 10 2 to 10 3 atoms coupled loosely together is formed by adiabatic expansion ejecting the vapour of materials into a high-vacuum region through the nozzle of a heated crucible. The clusters are ionised by electron bombardment and accelerated with neutral clusters toward a substrate. In this paper, mechanisms of cluster formation experimental results of the cluster size (atoms/cluster) and its distribution, and characteristics of the cluster ion beams are reported. The size is calculated from the kinetic equation E = (1/2)mNVsub(ej) 2 , where E is the cluster beam energy, Vsub(ej) is the ejection velocity, m is the mass of atom and N is the cluster size. The energy and the velocity of the cluster are measured by an electrostatic 127 0 energy analyser and a rotating disc system, respectively. The cluster size obtained for Ag is about 5 x 10 2 to 2 x 10 3 atoms. The retarding potential method is used to confirm the results for Ag. The same dependence on cluster size for metals such as Ag, Cu and Pb has been obtained in previous experiments. In the cluster state the cluster ion beam is easily produced by electron bombardment. About 50% of ionised clusters are obtained under typical operation conditions, because of the large ionisation cross sections of the clusters. To obtain a uniform spatial distribution, the ionising electrode system is also discussed. The new techniques are termed ionised-cluster beam deposition (ICBD) and epitaxy (ICBE). (author)

  19. Iranian 42/40 inch gas line to central Persia and USSR one of the world's largest

    Energy Technology Data Exchange (ETDEWEB)

    Naghavi, S; Manoochehri, N

    1969-03-01

    Iran Gas Trunkline consists of 1,120 km of 42 in./40 in. main pipeline, and 675 km of spur lines. It also consists of 104 km gas gathering lines, compression facilities for collection, treatment, and transportation of dry sweet gas to Shiraz, Esfahan and Tehran for industrial purposes in early spring 1970 and export gas to Russia during fall that year. The system will have an ultimate capacity for 1,650 MMscfd of gas equivalent to about 275,000 bpd of crude oil. Distribution will commence in Tehran and Esfahan in 1970, probably to industrial consumers only initially, but later on also to domestic and commercial users. Gas will be used extensively for power generation in these cities, the need for which is increasing rapidly. The source gas used in this pipeline would otherwise be flared to waste.

  20. Isotope separation system

    International Nuclear Information System (INIS)

    Lehmann, J.-C.

    1975-01-01

    A description is given of an isotope separation device comprising a system for converting into gaseous form a first and second isotope to be separated, a monochromatic excitation light source to excite the gaseous molecules of these two isotopes in a distinct manner, a first and second receiver to collect selectively the molecules of the first and second distinctly excited isotopes. The frequency FL of the excitation light is selected between a lower limit and a higher limit F2 + 1/2 LD, depending on the frequences F1 and F2 of two absorption lines near this first and second isotope. The difference DF between these two frequencies F1 and F2 is less than the Doppler width LD of each one of these lines and greater than the natural width LN of each of these two lines and also the width of line LR of the excitation light source. The probability that the molecules will be excited by this light depends on the direction of their displacement to a major and different extent for both isotopes. An ionising light source LI is set up to irradiate the seat of interaction between the excitation light and the gaseous molecules with an ionisation light able to ionise the excited molecules without ionising the molecules that are not excited. The receivers are able to collect selectively the ionised molecules. A sufficiently low gas pressure is selected for the distance between the place of interaction and the first receiver to be less than double the free mean travel of the molecules in the gas [fr

  1. The ENEA calibration service for ionising radiations

    International Nuclear Information System (INIS)

    Monteventi, F.; Sermenghi, I.

    1999-01-01

    The report describes all the facilities available at the the service of the ENEA Calibration Service for Ionising Radiations at Bologna (Italy). It gives a detailed description of all equipments qualified for photon fields metrology including the secondary standards and the calibration procedures performed for radiation monitoring devices and dosemeters [it

  2. Use of voltammetry for in vitro equilibrium and transport studies of ionisable drugs

    Directory of Open Access Journals (Sweden)

    Matej Velicky

    2014-09-01

    Full Text Available In this review, we will briefly outline the voltammetric investigations of the transfer of ionisable drugs at the interface between two immiscible electrolyte solutions. The voltammetric techniques enable the determination of some key in vitro properties of ionisable drugs, including partition coefficient, diffusion coefficient and membrane permeability. Some successful applications will be highlighted, together with the background methodologies.

  3. Cost considerations for an ionising energy treatment facility

    International Nuclear Information System (INIS)

    Culpitt, R.A.

    1985-01-01

    Variables influencing the cost of food irradiation can be included under three broad headings: the physical characteristics of products to be treated; the operational characteristics of the plant to be used; costs of establishment and operation of an ionising energy treatment

  4. Increasing of MERARG experimental performances: on-line fission gas release measurement by mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Pontillon, Y.; Capdevila, H.; Clement, S. [CEA, DEN, DEC, SA3C, LAMIR, F-13108 Saint Paul lez Durance, (France); Guigues, E.; Janulyte, A.; Zerega, Y.; Andre, J. [Aix-Marseille Universite, LISA EA 4672, 13397 MARSEILLE cedex 20, (France)

    2015-07-01

    The MERARG device - implemented at the LECASTAR Hot Laboratory, at the CEA Cadarache - allows characterizing nuclear fuels with respect to the behaviour of fission gases during thermal transients representative of normal or off normal operating nuclear power plant conditions. The fuel is heated in order to extract a part or the total gas inventory it contains. Fission Gas Release (FGR) is actually recorded by mean of both on-line gamma spectrometry station and micro gas chromatography. These two devices monitor the quantity and kinetics of fission gas release rate. They only address {sup 85}Kr radioactive isotope and the elemental quantification of Kr, Xe and He (with a relatively low detection limit in the latter case, typically 5-10 ppm). In order to better estimate the basic mechanisms that promote fission gas release from irradiated nuclear fuels, the CEA fuel study department decided to improve its experimental facility by modifying MERARG to extend the studies of gamma emitter fission gases to all gases (including Helium) with a complete isotopic distribution capability. To match these specifications, a Residual Gas Analyser (RGA) has been chosen as mass spectrometer. This paper presents a review of the main aspects of the qualification/calibration phase of the RGA type analyser. In particular, results recorded over three mass ranges 1-10 u, 80-90 u and 120-140 u in the two classical modes of MERARG, i.e. on-line and off-line measurements are discussed. Results obtained from a standard gas bottle show that the quantitative analysis at a few ppm levels can be achieved for all isotopes of Kr and Xe, as well as masses 2 and 4 u. (authors)

  5. Possibilities of UV laser oscillation on aluminium ion lines

    NARCIS (Netherlands)

    Grozeva, M.; Mihailova, D.B.; Sabotinov, N.

    2006-01-01

    An analysis of the general energy level structure of the singly ionised Al is made. It is found that in the UV spectrum of Al II there are many intensive lines starting from levels which can be populated selectively via charge transfer collisions with either helium or neon ions. The emission

  6. Biological Effects of Ionising Radiation and Countermeasures (Les effets biologiques des rayonnements ionisants et leurs contre-mesures)

    Science.gov (United States)

    2018-01-01

    radiation physicists. As an example, a special issue of Health Physics [3] presents a body of experimental work characterizing the outdoor...Terrorist Attack involving Ionising Radiation. Campus Vesta, Belgium September 25-29, 2016. [3] Health Physics (Special Issue) 2016:110;399- 547...of Radiobiology & Radiation Protection 128 Szaserów Street 04-141 Warsaw POLAND Email: mjaniak@wihe.waw.pl Mr. Tjerk KUIPERS Health Physics

  7. An enhanced ionising radiation monitoring and detecting technique in radiotherapy units of hospitals using wireless sensor networks

    International Nuclear Information System (INIS)

    Ali, Peter

    2017-01-01

    In this paper, a solution of ionising radiation monitoring based on the concept of Wireless Sensor Network (WSN), is presented. Radiation dose rate measured by the sensor node is sent to the monitoring station through ZigBee wireless network operated on 2.4 GHz unlicensed Industrial Scientific Medical (ISM) band. The system is calibrated for use for ionizing radiation dose rate range of between amount of ionising radiation observed in radiotherapy unit of a hospital and 1.02 mSv/h. Power consumption of the sensor node is kept low by operating the node ZigBee radio with low duty cycle: i.e. by keeping the radio awake only during data transmission/reception. Two ATmega8 microcontrollers, one each for sensor node and the monitoring station, are programmed to perform interfacing, data processing, and control functions. The system range of coverage is 124m for outdoor (line of site) deployment and 56.8m for indoor application where 5 brick walls separated the sensor node and the monitoring station. Range of coverage of the system is extendable via the use of ZigBee router (s)

  8. Student and intern awareness of ionising radiation exposure from common diagnostic imaging procedures

    International Nuclear Information System (INIS)

    Zhou, G. Z.; Wong, D. D.; Nguyen, L. K.; Mendelson, R. M.

    2010-01-01

    Full text: This study aims to evaluate medical student and intern awareness of ionising radiation exposure from common diagnostic imaging procedures and to suggest how education could be improved. Fourth to sixth year medical students enrolled at a Western Australian university and interns from three teaching hospitals in Perth were recruited. Participants were asked to complete a questionnaire consisting of 26 questions on their background, knowledge of ionising radiation doses and learning preferences for future teaching on this subject. A total of 331 completed questionnaires were received (95.9%). Of the 17 questions assessing knowledge of ionising radiation, a mean score of 6.0 was obtained by respondents (95% CI 5.8-6.2). Up to 54.8% of respondents underestimated the radiation dose from commonly requested radiological procedures. Respondents (11.3 and 25.5%) incorrectly believed that ultrasound and MRI emit ionising radiation, respectively. Of the four subgroups of respondents, the intern doctor subgroup performed significantly better (mean score 6.9, P< 0.0001, 95% CI 6.5-7.3) than each of the three medical student subgroups. When asked for the preferred method of teaching for future radiation awareness, a combination of lectures, tutorials and workshops was preferred. This study has clearly shown that awareness of ionising radiation from diagnostic imaging is lacking among senior medical students and interns. The results highlight the need for improved education to minimise unnecessary exposure of patients and the community to radiation. Further studies are required to determine the most effective form of education.

  9. Metabolic changes in broiler chickens exposed to low dose of ionising radiation

    International Nuclear Information System (INIS)

    Danova, D.; Kafka, I.; Kalenicova, Z.; Petrovova, E.; Toropila, M.

    2008-01-01

    In our experiment broiler chickens, 28-day old, were exposed to single whole- body dose 3 Gy of ionising radiation in time gap 3., 7., 14. and 21 day. We applied zinc to organism of chicks after irradiation. We observed changes of concentrations of cholesterol and glucose in blood serum. From obtained results it is evident that despite relative high resistance of poultry to irradiation, it reacts strongly to ionising radiation even at laboratory levels. (authors)

  10. Single-stage accelerator mass spectrometer radiocarbon-interference identification and positive-ionisation characterisation

    Energy Technology Data Exchange (ETDEWEB)

    Wilcken, K.M., E-mail: klaus.wilcken@ansto.gov.au [Scottish Universities Environmental Research Centre, Scottish Enterprise Technology Park, East Kilbride G75 0QF (United Kingdom); Freeman, S.P.H.T.; Xu, S.; Dougans, A. [Scottish Universities Environmental Research Centre, Scottish Enterprise Technology Park, East Kilbride G75 0QF (United Kingdom)

    2013-01-15

    A single-stage accelerator mass spectrometer (SSAMS) is a good alternative to conventional spectrometers based on tandem electrostatic acceleration for radiocarbon measurement and permits experimentation with both negative and positive carbon ions. However, such {sup 14}C AMS of either polarity ions is limited by an interference. In the case of anion acceleration we have newly determined this to be summed {sup 13}C and {sup 16}O by improvising an additional Wien filter on our SSAMS deck. Also, {sup 14}C AMS might be improved by removing its dependency on negative-ionisation in a sputter ion source. This requires negative-ionisation of sample atoms elsewhere to suppress the {sup 14}N interference, which we accomplish by transmitting initially positive ions through a thin membrane. The ionisation dependence on ion-energy is found to be consistent with previous experimentation with vapours and thicker foils.

  11. SDSS-IV MaNGA: the impact of diffuse ionized gas on emission-line ratios, interpretation of diagnostic diagrams and gas metallicity measurements

    Science.gov (United States)

    Zhang, Kai; Yan, Renbin; Bundy, Kevin; Bershady, Matthew; Haffner, L. Matthew; Walterbos, René; Maiolino, Roberto; Tremonti, Christy; Thomas, Daniel; Drory, Niv; Jones, Amy; Belfiore, Francesco; Sánchez, Sebastian F.; Diamond-Stanic, Aleksandar M.; Bizyaev, Dmitry; Nitschelm, Christian; Andrews, Brett; Brinkmann, Jon; Brownstein, Joel R.; Cheung, Edmond; Li, Cheng; Law, David R.; Roman Lopes, Alexandre; Oravetz, Daniel; Pan, Kaike; Storchi Bergmann, Thaisa; Simmons, Audrey

    2017-04-01

    Diffuse ionized gas (DIG) is prevalent in star-forming galaxies. Using a sample of 365 nearly face-on star-forming galaxies observed by Mapping Nearby Galaxies at APO, we demonstrate how DIG in star-forming galaxies impacts the measurements of emission-line ratios, hence the interpretation of diagnostic diagrams and gas-phase metallicity measurements. At fixed metallicity, DIG-dominated low ΣHα regions display enhanced [S II]/Hα, [N II]/Hα, [O II]/Hβ and [O I]/Hα. The gradients in these line ratios are determined by metallicity gradients and ΣHα. In line ratio diagnostic diagrams, contamination by DIG moves H II regions towards composite or low-ionization nuclear emission-line region (LI(N)ER)-like regions. A harder ionizing spectrum is needed to explain DIG line ratios. Leaky H II region models can only shift line ratios slightly relative to H II region models, and thus fail to explain the composite/LI(N)ER line ratios displayed by DIG. Our result favours ionization by evolved stars as a major ionization source for DIG with LI(N)ER-like emission. DIG can significantly bias the measurement of gas metallicity and metallicity gradients derived using strong-line methods. Metallicities derived using N2O2 are optimal because they exhibit the smallest bias and error. Using O3N2, R23, N2 = [N II]/Hα and N2S2Hα to derive metallicities introduces bias in the derived metallicity gradients as large as the gradient itself. The strong-line method of Blanc et al. (IZI hereafter) cannot be applied to DIG to get an accurate metallicity because it currently contains only H II region models that fail to describe the DIG.

  12. Diseases induced by ionising radiation

    International Nuclear Information System (INIS)

    1984-11-01

    An interim report is presented by the Industrial Injuries Advisory Council in accordance with Section 141 of the Social Security Act 1975 on the question whether the terms of prescription for occupational diseases induced by ionising radiation should be amended to cover a wider range of conditions. A lack of persuasive statistical data has prevented reliable estimates of health risks of radiation workers in the UK to be made. However the report gives details of the progress made so far and the difficulties encountered. (U.K.)

  13. Imaging spectrophotometry of ionized gas in NGC 1068. I - Kinematics of the narrow-line region

    Science.gov (United States)

    Cecil, Gerald; Bland, Jonathan; Tully, R. Brent

    1990-01-01

    The kinematics of collisionally excited forbidden N II 6548, 6583 across the inner 1 arcmin diameter of the nearby Seyfert galaxy NGC 1068 is mapped using an imaging Fabry-Perot interferometer and low-noise CCD. The stack of monochromatic images, which spatially resolved the high-velocity gas, was analyzed for kinematic and photometric content. Profiles agree well with previous long-slit work, and their complete spatial coverage makes it possible to constrain the gas volume distribution. It is found that the narrow-line region is distributed in a thick center-darkened, line-emitting cylinder that envelopes the collimated radio jet. Three distinct kinematic subsystems, of which the cylinder is composed, are discussed in detail. Detailed behavior of the emission-line profiles, at the few points in the NE quadrant with simple kinematics, argues that the ionized gas develops a significant component of motion perpendicular to the jet axis.

  14. HOT GAS LINES IN T TAURI STARS

    International Nuclear Information System (INIS)

    Ardila, David R.; Herczeg, Gregory J.; Gregory, Scott G.; Hillenbrand, Lynne A.; Ingleby, Laura; Bergin, Edwin; Bethell, Thomas; Calvet, Nuria; France, Kevin; Brown, Alexander; Edwards, Suzan; Johns-Krull, Christopher; Linsky, Jeffrey L.; Yang, Hao; Valenti, Jeff A.; Abgrall, Hervé; Alexander, Richard D.; Brown, Joanna M.; Espaillat, Catherine; Hussain, Gaitee

    2013-01-01

    For Classical T Tauri Stars (CTTSs), the resonance doublets of N V, Si IV, and C IV, as well as the He II 1640 Å line, trace hot gas flows and act as diagnostics of the accretion process. In this paper we assemble a large high-resolution, high-sensitivity data set of these lines in CTTSs and Weak T Tauri Stars (WTTSs). The sample comprises 35 stars: 1 Herbig Ae star, 28 CTTSs, and 6 WTTSs. We find that the C IV, Si IV, and N V lines in CTTSs all have similar shapes. We decompose the C IV and He II lines into broad and narrow Gaussian components (BC and NC). The most common (50%) C IV line morphology in CTTSs is that of a low-velocity NC together with a redshifted BC. For CTTSs, a strong BC is the result of the accretion process. The contribution fraction of the NC to the C IV line flux in CTTSs increases with accretion rate, from ∼20% to up to ∼80%. The velocity centroids of the BCs and NCs are such that V BC ∼> 4 V NC , consistent with the predictions of the accretion shock model, in at most 12 out of 22 CTTSs. We do not find evidence of the post-shock becoming buried in the stellar photosphere due to the pressure of the accretion flow. The He II CTTSs lines are generally symmetric and narrow, with FWHM and redshifts comparable to those of WTTSs. They are less redshifted than the CTTSs C IV lines, by ∼10 km s –1 . The amount of flux in the BC of the He II line is small compared to that of the C IV line, and we show that this is consistent with models of the pre-shock column emission. Overall, the observations are consistent with the presence of multiple accretion columns with different densities or with accretion models that predict a slow-moving, low-density region in the periphery of the accretion column. For HN Tau A and RW Aur A, most of the C IV line is blueshifted suggesting that the C IV emission is produced by shocks within outflow jets. In our sample, the Herbig Ae star DX Cha is the only object for which we find a P-Cygni profile in the C IV

  15. Outflow Kinematics Manifested by the Hα Line: Gas Outflows in Type 2 AGNs. IV

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Daeun; Woo, Jong-Hak; Bae, Hyun-Jin, E-mail: woo@astro.snu.ac.kr [Astronomy Program, Department of Physics and Astronomy, Seoul National University, Seoul 151-742 (Korea, Republic of)

    2017-08-20

    Energetic ionized gas outflows driven by active galactic nuclei (AGNs) have been studied as a key phenomenon related to AGN feedback. To probe the kinematics of the gas in the narrow-line region, [O iii] λ 5007 has been utilized in a number of studies showing nonvirial kinematic properties due to AGN outflows. In this paper, we statistically investigate whether the H α emission line is influenced by AGN-driven outflows by measuring the kinematic properties based on the H α line profile and comparing them with those of [O iii]. Using the spatially integrated spectra of ∼37,000 Type 2 AGNs at z < 0.3 selected from the Sloan Digital Sky Survey DR7, we find a nonlinear correlation between H α velocity dispersion and stellar velocity dispersion that reveals the presence of the nongravitational component, especially for AGNs with a wing component in H α . The large H α velocity dispersion and velocity shift of luminous AGNs are clear evidence of AGN outflow impacts on hydrogen gas, while relatively smaller kinematic properties compared to those of [O iii] imply that the observed outflow effect on the H α line is weaker than the case of [O iii].

  16. Medical use of ionising radiation - challenges for the third millennium

    International Nuclear Information System (INIS)

    Leitz, W.

    2003-01-01

    From the very beginning after its discovery ionising radiation has been in beneficial use for health care. But even the drawbacks showed up very early: only a few months after Roentgens discovery reports were published on patients who got severe skin damage after fluoroscopy with x-rays. This finding of the adverse effects was soon turned into something positive: ionising radiation could be used for treatment of cancer. In 1928 radiologists took the initiative to the foundation of what later became the International Commission on Radiological Protection, ICRP. Medical use of ionising radiation is giving by far the largest contribution to the radiation burden of the global population from artificial sources, on average 0,3 mSv per year and inhabitant, excluding doses from radiation treatment. In the Nordic countries this dose is approximately 0,7 mSv. This isn't a problem by itself. The total benefit is exceeding the total radiation risk with large margins. But the margins could even be larger. Methods for examinations and treatments have often a potential for improvements, meaning that the medical effect can be obtained with a lower dose to the patient. In certain circumstances the examination does not contribute to the further treatment of the patient or to her/his well-being and is then regarded as not justified. The huge challenge we are facing depends among other things on the extreme fast technical development which enables exposures of a magnitude that we haven't seen before and applications we only could dream about. There is a risk that the motto 'do what is possible to do' is followed instead of 'do what the individual patient needs'. This presentation addresses the possibilities, but also the dangers that medical use of ionising radiation in medical care is facing in the new millennium, or at least in its first years. (orig.)

  17. Full Ionisation In Binary-Binary Encounters With Small Positive Energies

    Science.gov (United States)

    Sweatman, W. L.

    2006-08-01

    Interactions between binary stars and single stars and binary stars and other binary stars play a key role in the dynamics of a dense stellar system. Energy can be transferred between the internal dynamics of a binary and the larger scale dynamics of the interacting objects. Binaries can be destroyed and created by the interaction. In a binary-binary encounter, full ionisation occurs when both of the binary stars are destroyed in the interaction to create four single stars. This is only possible when the total energy of the system is positive. For very small energies the probability of this occurring is very low and it tends towards zero as the total energy tends towards zero. Here the case is considered for which all the stars have equal masses. An asymptotic power law is predicted relating the probability of full ionisation with the total energy when this latter quantity is small. The exponent, which is approximately 2.31, is compared with the results from numerical scattering experiments. The theoretical approach taken is similar to one used previously in the three-body problem. It makes use of the fact that the most dramatic changes in scale and energies of a few-body system occur when its components pass near to a central configuration. The position, and number, of these configurations is not known for the general four-body problem, however, with equal masses there are known to be exactly five different cases. Separate consideration and comparison of the properties of orbits close to each of these five central configurations enables the prediction of the form of the cross-section for full ionisation for the case of small positive total energy. This is the relation between total energy and the probability of total ionisation described above.

  18. Experimental verification of the gas pumping theory within fission ionisation chambers

    International Nuclear Information System (INIS)

    Bartlett, A.C.

    1975-01-01

    Experimental verification of a theory for gas loss from in-core ionization chambers is reported. A value of the gas pressure within an irradiated miniature fission chamber was derived indirectly by use of published data on Townsend first coefficient/field across the detector as a function of field/pressure. In practice the voltage corresponding to 10% current multiplication is measured. From the current saturation characteristics measured on the detector during irradiation, the change in gas pressure as a function of fluence was derived and compared to theoretically predicted values. Within the limited accuracy obtainable substantial agreement between measurement and theory is obtained. (O.T.)

  19. A self-calibrating ionisation chamber for the precise intensity calibration of high-energy heavy-ion beam monitors

    International Nuclear Information System (INIS)

    Junghans, A.

    1996-01-01

    The intensity of a 136 Xe(600 A MeV) beam has been determined by simultaneously measuring the particle rate and the corresponding ionisation current with an ionisation chamber. The ionisation current of this self-calibrating device was compared at higher intensities with the current of a secondary-electron monitor and a calibration of the secondary-electron current was achieved with a precision of 2%. This method can be applied to all high-energy heavy-ion beams. (orig.)

  20. On-line sodium and cover as purity monitors gas operating tools at EBR-II

    International Nuclear Information System (INIS)

    Smith, C.R.F.; Richardson, W.J.; Holmes, J.T.

    1976-01-01

    Plugging temperature indicators, electrochemical oxygen meters and hydrogen diffusion meters are the on-line sodium purity monitors now in use at EBR-II. On-line gas chromatographs are used to monitor helium, hydrogen, oxygen and nitrogen impurities in the argon cover gases. Monitors for tritium-in-sodium and for hydrocarbons-in-cover gas have been developed and are scheduled for installation in the near future. An important advantage of on-line monitors over the conventional grab-sampling techniques is the speed of response to changing reactor conditions. This helps us to identify the source of the impurity, whether the cause may be transient or constant, and take corrective action as necessary. The oxygen meter is calibrated monthly against oxygen in sodium determined by the vanadium wire equilibration method. The other instruments either do not require calibration or are self-calibrating. The ranges, sensitivity and response times of all of the on-line purity monitors has proven satisfactory under EBR-II operating conditions

  1. Electron impact ionisation cross-sections of 2-heptanone

    Science.gov (United States)

    Vacher, J. R.; Blin-Simiand, N.; Jorand, F.; Pasquiers, S.

    2005-01-01

    The electron impact ionisation of 2-heptanone between 13 and 78 eV is studied using mass spectrometry. CH3C(O)CH2CH2CH2CH2CH3+ and fragment ions are produced with a total cross-section of 5 × 10-16 cm2 towards 50 eV. Two ions, identified as CH3CO+ (43 amu) and CH3C(OH)CH2+ (58 amu), contribute to about 60% of the total cross-section for electron energies above the ionisation threshold. The detected ions are identified using ab initio calculations. For E = 14 eV, the ion of 58 amu is the most abundant followed by an ion of 59 amu identified as being CH3C(OH)CH3+; they result from a bond cleavage with one or two H atom rearrangements. For E >= 48 eV, the ion of 43 amu is the most abundant; it results from an [alpha]-cleavage reaction in the molecular ion.

  2. Application of R-Matrix with Time-dependence Theory to Double Ionisation Using a 2-electron Outer Region

    International Nuclear Information System (INIS)

    Wragg, Jack; Parker, J S; Van der Hart, H W

    2015-01-01

    R-Matrix with Time-dependence (RMT) theory has been extended to cover double-ionisation processes. An application to photoionisation of He is demonstrated, with an emphasis on double-ionisation cross sections. (paper)

  3. Deployment of the FIGAERO Iodide Time of flight (ToF)-Chemical ionisation mass spectrometer (CIMS) using X-ray ionisation in Manaus

    Science.gov (United States)

    Bannan, T.; Bacak, A.; Priestley, M.; Adelstein, E.; Worrall, S.; Artaxo, P.; Carbone, S.; Topping, D. O.; Allan, J. D.; Coe, H.; Percival, C.

    2017-12-01

    Here the deployment of the The Filter Inlet for Gases and AEROsols (FIGAERO) coupled with the Aerodyne High Resolution (HR)-Time of flight (ToF)-Chemical ionisation mass spectrometer (CIMS) in Manaus is presented. This project utilised the Tofwerk X-ray ionisation source in the tropical rainforest in close proximity to Manaus, Brazil, at the ZF2 measurement site. The FIGAERO is a filter based technique that provides simultaneous molecular information of both the gas and particle phase. When analysing particles that have been collected the evolution of the MS signals from different compounds change independently as a function of temperature; creating a thermogram that is m/z specific. The temperature for which the desorbed signal shows a maximum for each compound has been used previously to extract vapour pressure information in laboratory characterisatio. Krieger et al. (2017) defined the homologous series of polyethylene glycols as a series of compounds that showed a very good agreement over a wide range of atmospherically relevant vapour pressures between different experimental setups. PEG samples therefore provide an ideal bench mark for characterising individual FIGAERO inlets to give vapour pressure information essential for partitioning characterisation. The PEG calibration curve has been used to validate vapour pressure measurements in a well-defined single component bases and in simple chamber experiments, results of which are presented. With a high reactivity and large ubiquitous global source, isoprene has a profound effect upon atmospheric chemistry and composition. Despite this there are still significant gaps in the understanding of the processes that lead to isoprene derived secondary organic aerosol (SOA). This project aims to provide insights into the role of isoprene in the mechanisms of production of SOA and its importance in the particulate mass budgets in the tropics and the fundamental chemical processes. The volatility and composition of

  4. Isotope shifts in odd and even energy levels of the neutral and singly ionised gadolinium atom

    International Nuclear Information System (INIS)

    Ahmad, S.A.; Venugopalan, A.; Saksena, G.D.

    1979-01-01

    Isotope shift studies in the gadolinium spectra have been extended in the region 4140 to 4535 A. Isotope shift Δσ(156 to 160) have been measured in 315 lines of the neutral and singly ionised gadolinium atom using a recording Fabry-Perot Spectrometer and gadolinium samples enriched in 156 Gd and 160 Gd isotopes. Some of the Gd I lines studied involve transitions from newly identified high odd levels of 4f 8 6s6p, 4f 7 5d6s7s and 4f 7 5d 3 configurations to low even levels of 4f 8 6s 2 and 4f 7 6s 2 6p configurations. Electronic configurations of the energy levels have been discussed on the basis of observed isotope shifts. In some cases assigned configurations have been revised and probable configurations have been suggested. (author)

  5. Health Services management. Health Service use of ionising radiations

    International Nuclear Information System (INIS)

    1989-12-01

    This circular consolidates and updates advice on the statutory and management responsibilities of Health Authorities in relation to the use of ionising radiations (including radioactive substances) on premises controlled by them and/or by persons employed by them (author)

  6. A new thermal ionisation mass spectrometer

    International Nuclear Information System (INIS)

    Haines, C.; Merren, T.O.; Unsworth, W.D.

    1979-01-01

    The Isomass 54E, a new thermal ionisation mass spectrometer for precise measurements of isotopic composition is described in detail. It combines the fruits of three development pro ects, viz. automation, energy filters and extended geometry with existing micromass expertise and experience. The hardware and software which are used for the automation as well as the energy filter used, are explained. The 'extended geometry' ion optical system adopted for better performance is discussed in detail. (K.B.)

  7. On-line system on the base of the ELEKTRONIKA D3-28 microcomputer for gas filling

    International Nuclear Information System (INIS)

    Artemov, A.A.; Baranchuk, N.S.; Livitskij, M.M.; Platonov, V.P.; Chernyak, V.Ya.

    1989-01-01

    On-line system for gas filling on the base of SNA-1 pressure controller, ELEKTRONIKA D3-28 microcomputer and interface device and program for information exchange within the system are described. The system is designed for on-line measurement of gas pressure and filling and is used during operation without pumping out. Volume of vacuum chamber is 0.8 m 3 , pressure of filled-out gas (nitrogen) is 1 atm. The system enables to change pressure up to 0.1 Torr with 1x10 -4 Torr accuracy. Actuation time of g as filling-on system is determined with program control and depends on pressure measurement. Minimal actuation time of gas filling-on system is determined with program control and depends on pressure measurement. Minimal actuation time is 12 ms

  8. Evaluation of three gas chromatography and two direct mass spectrometry techniques for aroma analysis of dried red bell peppers

    NARCIS (Netherlands)

    Ruth, van S.M.; Boscaini, E.; Mayr, D.; Pugh, J.; Posthumus, M.A.

    2003-01-01

    Three gas chromatography methods and two direct mass spectrometry techniques were compared for the analysis of the aroma of rehydrated diced red bell peppers. Gas chromatography methods included systems with olfactometry detection (GC-O), flame ionisation detection (GC-FID) and mass spectrometry

  9. Additives in UV and ionising radiation grafting and curing processes

    International Nuclear Information System (INIS)

    Garnett, J.L.; Ng, L.T.; Viengkhou, V.

    1998-01-01

    Full text: Curing of polymers induced by both UV and ionising radiation are now established technologies. Currently both systems are predominantly based on acrylate chemistry. UV processes use photoinitiators to achieve fast polymerisation. In the proposed paper the significance of the occurrence of concurrent grafting with cure will be examined. particularly with respect to the recycling of finished product. Basic studies on grafting initiated by UV and ionising radiation will be discussed. Polar methyl methacrylate (MMA) and non-polar styrene will be used as representative monomers with cellulose and propylene typifying the backbone polymers. The additives chosen for examination in this study are predominantly components used in radiation curing formulations since grafting and curing are known to be mechanically related. The additives used were mineral acid, photoinitiators, vinyl ethers, oligomers, polyfunctional monomers including multifunctional acrylates (MFAs) and methacrylates (MFMAs). For the first time the use of charge transfer complexes in the Mulliken sense as additives in radiation grafting will be discussed. The CT complexes themselves, being monomers, have also been grafted to the above polymers. Recent developments with excimer laser sources for initiating these processes will be discussed, especially the use of non-acrylate chemistry. Excimer laser sources are shown to complement conventional UV and ionising radiation and are photoinitiator free. Mechanisms for the above grafting and curing processes will be outlined

  10. Interaction of rare gas clusters in intense laser field

    International Nuclear Information System (INIS)

    Dobosz, Sandrine

    1998-01-01

    Rare gas cluster jet targets have only been scarcely studied in strong laser fields. This is surprising since their properties are particularly appealing. Although considered as a gas phase target, the local density within clusters is comparable to that of the bulk. Intense irradiation of clusters produces a plasma thereby giving rise to strong collisional heating. This explains, in particular, the observation of very high fragment charge states and the generation of X-rays in the keV energy range. The complete set of our experimental results shows that the intra-cluster atoms are first ionised by tunnel ionisation followed by massive electron impact ionisation. Thus, for Xenon clusters, we have observed up to 30-fold charged. The most energetic electrons leave the cluster which contributes to a positive charge build-up on the cluster surface. The plasma expands under the combined action of the Coulomb and kinetic pressures. The contribution of each pressure depends on the cluster size and we show that the Coulomb pressure is prevailing for the smallest sizes. This scenario explains the ejection of fragments with energies of up to lMeV. We have also performed a high resolution X-ray study to explore in situ the properties of the plasma. These studies underline the importance of electron-ion collisions and allow to deterrnine the mean charge states of the emitting ions. Finally, we have developed a model, describing the cluster expansion, which confirms our experimental observations. (author) [fr

  11. Continuous determination of volatile products in anaerobic fermenters by on-line capillary gas chromatography

    International Nuclear Information System (INIS)

    Diamantis, V.; Melidis, P.; Aivasidis, A.

    2006-01-01

    Bio-ethanol and biogas produced during the anaerobic conversion of organic compounds has been a subject of great interest since the oil crisis of the 1970s. In ethanol fermentation and anaerobic treatment of wastewaters, end-product (ethanol) and intermediate-products (short-chain fatty acids, SCFA) cause inhibition that results in reduced process efficiency. Control of these constituents is of utmost importance for bioreactor optimization and process stability. Ethanol and SCFA can be detected with precision by capillary gas chromatography usually conducted in off-line measurements. In this work, an on-line monitoring and controlling system was developed and connected to the fermenter via an auto-sampling equipment, which could perform the feeding, filtration and dilution of the sample and final injection into the gas chromatograph through an automation-based programmed procedure. The sample was continuously pumped from the recycle stream of the bioreactor and treated using a microfiltration unit. The concentrate was returned to the reactor while the permeate was quantitatively mixed with an internal standard solution. The system comprised of a gas chromatograph with the flow cell and one-shot sampler and a PC with the appropriate software. The on-line measurement of ethanol and SCFA, directly from the liquid phase of an ethanol fermenter and a high-rate continuous mode anaerobic digester, was accomplished by gas chromatography. Also, this monitoring and controlling system was proved to be effective in the continuous fermentation of alcohol-free beer

  12. S.I. No 125 of 2000 Radiological Protection Act 1991 (ionising radiation) Order 2000

    International Nuclear Information System (INIS)

    2000-01-01

    This statutory instrument provides for the implementation of Council Directive 96/29/Euratom of 13 May 1996 laying down basic safety standards for the protection of the health of workers and the general public against the dangers arising from ionising radiation. It also incorporates the provisions of Council Directive 90/641/Euratom of 4 December 1990 on the operational protection of outside workers exposed to the risk of ionising radiation during their activities in controlled areas. It replaces the provisions of the European Communities (Ionising Radiation) Regulations, 1991 (S.I. No. 43 of 1991), the Radiological Protection Act, 1991 (General Control of Radioactive Substances, Nuclear Devices and Irradiating Apparatus) Order, 1993 (S.I. No. 151 of 1993) and the European Communities (Protection of Outside Workers from Ionising Radiation) Regulations, 1994 (S.I. No. 144 of 1994). The main changes introduced in this Order are: the inclusion of work activities involving exposure to natural sources of radiation, stricter application of existing radiation protection principles through the introduction of lower dose limits, the use of dose constraints in keeping doses as low as reasonably achievable (i.e. optimisation process) and extended application of justification principles, the introduction of radiation protection principles for intervention in cases of radiological emergencies or lasting exposures. (author)

  13. Study on the wiping gas jet in continuous galvanizing line

    Science.gov (United States)

    Kweon, Yong-Hun; Kim, Heuy-Dong

    2011-09-01

    In the continuous hot-dip galvanizing process, the gas-jet wiping is used to control the coating thickness of moving steel strip. The high speed gas-jet discharged from the nozzle slot impinges on the strip, and at this moment, wipes the liquid coating layer dragged by a moving strip. The coating thickness is generally influenced on the flow characteristics of wiping gas-jet such as the impinging pressure distribution, pressure gradient and shear stress distribution on the surface of strip. The flow characteristics of wiping gas-jet mentioned above depends upon considerably both the process operating conditions such as the nozzle pressure, nozzle-to-strip distance and line speed, and the geometry of gas-jet wiping apparatus such as the height of nozzle slot. In the present study, the effect of the geometry of nozzle on the coating thickness is investigated with the help of a computational fluid dynamics method. The height of nozzle slot is varied in the range of 0.6mm to 1.7mm. A finite volume method (FVM) is employed to solve two-dimensional, steady, compressible Navier-Stokes equations. Based upon the results obtained, the effect of the height of nozzle slot in the gas-jet wiping process is discussed in detail. The computational results show that for a given standoff distance between the nozzle to the strip, the effective height of nozzle slot exists in achieving thinner coating thickness.

  14. NDT using ionising radiation in the Indian space programme

    International Nuclear Information System (INIS)

    Viswanathan, K.

    1997-01-01

    Ionising radiations continue to play a vital role in the Non-Destructive Evaluation (NDE) of various components used in space vehicles and satellites. The different Non-Destructive Testing (NDT) methods which are useful to the Indian space programme are discussed. 4 refs., 5 figs

  15. European Communities (Foodstuffs treated with ionising radiation) Regulations, 2000. Statutory Instrument S.I. No. 297 of 2000

    International Nuclear Information System (INIS)

    2000-01-01

    These Regulations give effect to Directive 1999/2/EC (the framework Directive) of the European Parliament and of the Council of 22 February 1999 on the approximation of the laws of the Member States concerning foods and food ingredients treated with ionising radiation and Directive 1999/3/EC (the implementing Directive) of the European Parliament and of the Council of 22 February 1999 on the establishment of a Community list of foods and food ingredients treated with ionising radiation. The effect of these Regulations is to lay down the general provisions for the treatment of foodstuffs with ionising radiation. Provisions concerning the approval and control of irradiation facilities and rules on labelling are also included. A positive list of foodstuffs authorised for treatment with ionising radiation and their maximum radiation doses are defined in the implementing Directive. These Regulations should be read together with the two Directives (author)

  16. Medical response to effects of ionising radiation

    International Nuclear Information System (INIS)

    Crosbie, W.A.; Gittus, J.H.

    1989-01-01

    The proceedings of a conference on 'Medical Response to Effects of Ionising Radiation' in 1989 in the form of nineteen papers published as a book. Topics discussed include radiation accidents at nuclear facilities, the medical management of radiation casualties, the responsibilities, plans and resources for coping with a nuclear accident and finally the long term effects of radiation, including leukaemia epidemiology studies. All papers were selected and indexed separately. (UK)

  17. Using the Properties of Broad Absorption Line Quasars to Illuminate Quasar Structure

    Science.gov (United States)

    Yong, Suk Yee; King, Anthea L.; Webster, Rachel L.; Bate, Nicholas F.; O'Dowd, Matthew J.; Labrie, Kathleen

    2018-06-01

    A key to understanding quasar unification paradigms is the emission properties of broad absorption line quasars (BALQs). The fact that only a small fraction of quasar spectra exhibit deep absorption troughs blueward of the broad permitted emission lines provides a crucial clue to the structure of quasar emitting regions. To learn whether it is possible to discriminate between the BALQ and non-BALQ populations given the observed spectral properties of a quasar, we employ two approaches: one based on statistical methods and the other supervised machine learning classification, applied to quasar samples from the Sloan Digital Sky Survey. The features explored include continuum and emission line properties, in particular the absolute magnitude, redshift, spectral index, line width, asymmetry, strength, and relative velocity offsets of high-ionisation C IV λ1549 and low-ionisation Mg II λ2798 lines. We consider a complete population of quasars, and assume that the statistical distributions of properties represent all angles where the quasar is viewed without obscuration. The distributions of the BALQ and non-BALQ sample properties show few significant differences. None of the observed continuum and emission line features are capable of differentiating between the two samples. Most published narrow disk-wind models are inconsistent with these observations, and an alternative disk-wind model is proposed. The key feature of the proposed model is a disk-wind filling a wide opening angle with multiple radial streams of dense clumps.

  18. Contribution to the study and use of ionisation chambers for nuclear reactor control (1965); Contribution a l'etude et a l'utilisation des chambres d'ionisation pour le controle des reacteurs nucleaires (1965)

    Energy Technology Data Exchange (ETDEWEB)

    Duchene, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-02-15

    At the moment ionisation chambers are the detectors which are best suited to the task of nuclear reactor control by neutronic measurements. We have thought it wise to state some generalities concerning reactor dynamics, the various neutron detection methods, the working of ionisation chambers and the measurement methods used. Our contribution to reactor control techniques consists on the one hand in an attempt to make a synthesis of the factors influencing the operation of ionisation chambers, the study of these factors, and on the other hand in the development of ionisation chambers of the fission and boron types, making it possible to follow the working of a reactor from the moment it starts up until maximum power is attained. In the field of fission chambers, we have in particular improved the technique for depositing uranium oxide on aluminium and have perfected the electrolytic deposition process on other metals: stainless steel, copper, molybdenum, nickel, tantalum, titanium, kovar, tungsten and beryllium. We have developed several types of fission chambers used during the start-up of reactors: one type of medium performance now in use in French piles one high-sensitivity type one high-temperature type which has operated up to 600 deg. C. As far as boron chambers are concerned, we have studied the perturbations caused to the measurement by the exposure of the chamber to high neutron flux and to a very strong {gamma} radiation. This exposure brings about a modification of the properties of the constituent materials and causes a background noise in the chamber which can seriously handicap the neutron measurements. We have shown that the compensation technique makes it possible to limit this noise and to thereby increase the range of measurement of conventional ionisation chambers intended for power measurements. Finally, we have built two types of compensation chambers used in the French reactors and have begun the study of a third type of high sensitivity for

  19. Ionising energy treatment of fresh fruit

    International Nuclear Information System (INIS)

    Rigney, C.J.

    1985-01-01

    The main purposes of the ionising energy treatment of fresh fruit are: the extension of shelf life of the commodity due to a direct physiological effect on the particular product; the extension of shelf life of the commodity due to a reduction in the development of moulds and rots which would normally render the product worthless; and the killing of insect pests of quarantine significance, to allow for normal marketing of fresh fruit without the risk of introducing insect pests to previously pest-free areas

  20. On-line mass spectrometry measurement of fission gas release from nuclear fuel submitted to thermal transients

    International Nuclear Information System (INIS)

    Guigues, E.; Janulyte, A.; Zerega, Y.; Pontillon, Y.

    2013-06-01

    The work presented in this paper has been performed in the framework of a joint research program between Aix-Marseille University and CEA Cadarache. The aim is to develop a mass spectrometer (MS) device for the MERARG facility. MERARG is devoted to the study of fission gas release measurement, from nuclear fuels submitted to annealing tests in high activity laboratory such as LECA-STAR, thanks to gamma spectrometry. The mass spectrometer will then extend the measurement capability from the γ-emitters gases to all the gases involved in the release in order to have a better understanding of the fission gas release dynamics from fuel during thermal transients. Furthermore, the mass spectrometer instrument combines the capabilities and performances of both on-line (for release kinetic) and off-line implementations (for delayed accurate analysis of capacities containing total release gas). The paper deals with two main axes: (1) the modelling of gas sampling inlet device and its performance and (2) the first MS qualification/calibration results. The inlet device samples the gas and also adapts the pressure between MERARG sweeping line at 1.2 bar and mass spectrometer chamber at high vacuum. It is a two-stage device comprising a capillary at inlet, an intermediate vacuum chamber, a molecular leak inlet and a two-stage pumping device. Pressure drops, conductance and throughputs are estimated both for mass spectrometer operation and for exhaust gas recovery. Possible gas segregation is also estimated and device modification is proposed to attain a more accurate calibration. First experimental results obtained from a standard gas bottle show that the quantitative analysis at a few ppm level can be achieved for all isotopes of Kr and Xe, as well as masses 2 and 4 u. (authors)

  1. Determination of N-nitrosamines in processed meats by liquid extraction combined with gas chromatography-methanol chemical ionisation/mass spectrometry.

    Science.gov (United States)

    Scheeren, Marina Bergoli; Sabik, Hassan; Gariépy, Claude; Terra, Nelcindo Nascimento; Arul, Joseph

    2015-01-01

    A simple, accessible and reproducible method was developed and validated as an alternative for the determination of nine volatile N-nitrosamines (NAs) in meat products, using a low volume of organic solvent and without requiring specific apparatus, offering the possibility of practical implementation in routine laboratories. The NAs were extracted with dichloromethane followed by a clean-up with phosphate buffer solution (pH 7.0). The extracts were analysed by gas chromatography-chemical ionisation/mass spectrometry (GC-CI/MS) in positive-ion mode using methanol as reagent. Limits of detection and quantification, recovery and reproducibility were determined for all NAs (N-nitrosodimethylamine, N-nitrosomethylethylamine, N-nitrosodiethylamine, N-nitrosopyrrolidine, N-nitrosodipropylamine, N-nitrosomorpholine, N-nitrosopiperidine, N-nitrosodibutylamine and N-nitrosodiphenylamine). Satisfactory sensitivity and selectivity were obtained even without concentrating the extract by solvent evaporation, avoiding the loss of the nine NAs studied. Limits of detection ranged from 0.15 to 0.37 µg kg(-1), whereas limits of quantification ranged from 0.50 to 1.24 µg kg(-1). Recoveries calculated in cooked ham that had been spiked at 10 and 100 µg kg(-1) were found to be between 70% and 114% with an average relative standard deviation of 13.2%. The method was successfully used to analyse five samples of processed meat products on the day of purchase and 7 days later (after storage at 4°C). The most abundant NAs found in the analysed products were N-nitrosodipropylamine and N-nitrosopiperidine, which ranged from 1.75 to 34.75 µg kg(-1) and from 1.50 to 4.26 µg kg(-1), respectively. In general, an increase in the level of NAs was observed after the storage period. The proposed method may therefore be a useful tool for food safety control once it allows assessing the profile and the dietary intake of NAs in food over time.

  2. Gas chromatography/sniffing port analysis of aroma compounds released under mouth conditions

    NARCIS (Netherlands)

    Ruth, van S.M.; Roozen, J.P.

    2000-01-01

    The release of aroma compounds from rehydrated French beans in an artificial mouth system and in the mouths of 12 assessors was studied by gas chromatography combined with flame ionisation detection and sniffing port detection. In an artificial mouth system, volatile compounds were isolated under

  3. Properties of an electret ionisation chamber for individual dosimetry in photon radiation fields

    International Nuclear Information System (INIS)

    Doerschel, B.; Pretzsch, G.

    1985-01-01

    The main properties of individual photon dosemeters are their energy and angular dependence and their measuring range and measurement accuracy. The determination of radiation exposure from the dosemeter readout is based on the choice of appropriate conversion factors, taking into account the influence of body backscatter on the dosemeter readout. The measurement range and accuracy of an electret ionisation chamber primarily depend on the electret stability and charge state measurement as well as on the chamber geometry. Dosimetric properties are described for an electret ionisation chamber designed for personnel monitoring. (author)

  4. ALICE TPC gas system is the first of the LHC experiments to be put on line

    CERN Document Server

    Maximilien Brice

    2006-01-01

    Picture 01 : the Physics Department's DT1 gas systems team in their laboratory. Picture 02 : Chilo Garabatos (ALICE) and Stefan Haider (PH-DT1-GS) in front of the gas system for the ALICE TPC which has just been put on line.

  5. A system for accurate on-line measurement of total gas consumption or production rates in microbioreactors

    NARCIS (Netherlands)

    van Leeuwen, Michiel; Heijnen, Joseph J.; Gardeniers, Johannes G.E.; Oudshoorn, Arthur; Noorman, Henk; Visser, Jan; van der Wielen, Luuk A.M.; van Gulik, Walter M.

    2009-01-01

    A system has been developed, based on pressure controlled gas pumping, for accurate measurement of total gas consumption or production rates in the nmol/min range, applicable for on-line monitoring of bioconversions in microbioreactors. The system was validated by carrying out a bioconversion with

  6. WHT spectroscopy of emission-line gas around two separate quasars at z = 0.87

    International Nuclear Information System (INIS)

    Fabian, A.C.; Crawford, C.S.; Johnstone, R.M.; Hewett, P.C.; Allington-Smith, J.R.

    1988-01-01

    A report is given of observations made with the Faint Object Spectrograph on the 4.2-m William Herschel Telescope (WHT), in which the line emission of the fuzz around two separate quasars, which coincidentally both have redshifts z = 0.87, is detected and measured. These represent the most distant quasars for which the spectrum of the fuzz has been obtained. The oxygen line ratios we observe are similar to those of the lower-z quasar 3C48 (to which the present quasars show a strong similarity) and again imply a high gas density. If confined by surrounding hot gas, the pressure is so high that an intracluster medium is required. This suggests that the quasars lie in clusters or groups of galaxies. (author)

  7. Nuclear recoil scintillation and ionisation yields in liquid xenon from ZEPLIN-III data

    Energy Technology Data Exchange (ETDEWEB)

    Horn, M., E-mail: m.horn@imperial.ac.uk [High Energy Physics group, Blackett Laboratory, Imperial College London (United Kingdom); Belov, V.A.; Akimov, D.Yu. [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Araujo, H.M. [High Energy Physics group, Blackett Laboratory, Imperial College London (United Kingdom); Barnes, E.J. [School of Physics and Astronomy, SUPA University of Edinburgh (United Kingdom); Burenkov, A.A. [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Chepel, V. [LIP-Coimbra and Department of Physics of the University of Coimbra (Portugal); Currie, A. [High Energy Physics group, Blackett Laboratory, Imperial College London (United Kingdom); Edwards, B. [Particle Physics Department, STFC Rutherford Appleton Laboratory, Chilton (United Kingdom); Ghag, C.; Hollingsworth, A. [School of Physics and Astronomy, SUPA University of Edinburgh (United Kingdom); Kalmus, G.E. [Particle Physics Department, STFC Rutherford Appleton Laboratory, Chilton (United Kingdom); Kobyakin, A.S.; Kovalenko, A.G. [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Lebedenko, V.N. [High Energy Physics group, Blackett Laboratory, Imperial College London (United Kingdom); Lindote, A. [LIP-Coimbra and Department of Physics of the University of Coimbra (Portugal); Particle Physics Department, STFC Rutherford Appleton Laboratory, Chilton (United Kingdom); Lopes, M.I. [LIP-Coimbra and Department of Physics of the University of Coimbra (Portugal); Luescher, R.; Majewski, P. [Particle Physics Department, STFC Rutherford Appleton Laboratory, Chilton (United Kingdom); Murphy, A.StJ. [School of Physics and Astronomy, SUPA University of Edinburgh (United Kingdom)

    2011-11-24

    Scintillation and ionisation yields for nuclear recoils in liquid xenon above 10 keV{sub nr} (nuclear recoil energy) are deduced from data acquired using broadband Am-Be neutron sources. The nuclear recoil data from several exposures to two sources were compared to detailed simulations. Energy-dependent scintillation and ionisation yields giving acceptable fits to the data were derived. Efficiency and resolution effects are treated using a light collection Monte Carlo, measured photomultiplier response profiles and hardware trigger studies. A gradual fall in scintillation yield below {approx}40 keV{sub nr} is found, together with a rising ionisation yield; both are in agreement with the latest independent measurements. The analysis method is applied to the most recent ZEPLIN-III data, acquired with a significantly upgraded detector and a precision-calibrated Am-Be source, as well as to the earlier data from the first run in 2008. A new method for deriving the recoil scintillation yield, which includes sub-threshold S1 events, is also presented which confirms the main analysis.

  8. Dense-gas properties in Arp 220 revealed by isotopologue lines

    Science.gov (United States)

    Wang, Junzhi; Zhang, Zhi-Yu; Zhang, Jiangshui; Shi, Yong; Fang, Min

    2016-02-01

    We present observations of isotopologue lines of dense-gas tracers at 3 mm and 1 mm towards the nearest ultra-luminous infrared galaxy Arp 220. The 3-mm and 1-mm observations were performed with the Institut de Radioastronomie Millimétrique 30-m telescope and the Atacama Pathfinder Experiment 12-m telescope, respectively. We detected H13CN and HN13C in 1-0 and 3-2, and HC15N 1-0, among which HC15N 1-0 and HN13C 1-0 are detected in Arp 220 for the first time. The H13CO+ 1-0 and 3-2 lines are unlikely to be detected because of the confusion of SiO lines. We find that the ratio of the line brightness temperatures of HN13C 3-2/1-0 is 2.4, which is significantly higher than that of H13CN 3-2/1-0 (0.73). This indicates that HN13C and HNC molecules are in denser regions than H13CN and HCN molecules. With the line ratio of H13CN 1-0 and HC15N 1-0, the 14N/15N ratio was estimated to be 440^{+140}_{-82}, which is larger than that of the local interstellar medium.

  9. A new in-gas-laser ionization and spectroscopy laboratory for off-line studies at KU Leuven

    International Nuclear Information System (INIS)

    Kudryavtsev, Yu.; Creemers, P.; Ferrer, R.; Granados, C.; Gaffney, L.P.; Huyse, M.; Mogilevskiy, E.; Raeder, S.; Sels, S.; Van den Bergh, P.; Van Duppen, P.; Zadvornaya, A.

    2016-01-01

    The in-gas laser ionization and spectroscopy (IGLIS) technique is used to produce and to investigate short-lived radioactive isotopes at on-line ion beam facilities. In this technique, the nuclear reaction products recoiling out of a thin target are thermalized and neutralized in a high-pressure noble gas, resonantly ionized by the laser beams in a two-step process, and then extracted from the ion source to be finally accelerated and mass separated. Resonant ionization of radioactive species in the supersonic gas jet ensures very high spectral resolution because of essential reduction of broadening mechanisms. To obtain the maximum efficiency and the best spectral resolution, properties of the supersonic jet and the laser beams must be optimized. To perform these studies a new off-line IGLIS laboratory, including a new high-repetition-rate laser system and a dedicated off-line mass separator, has been commissioned. In this article, the specifications of the different components necessary to achieve optimum conditions in laser-spectroscopy studies of radioactive beams using IGLIS are discussed and the results of simulations are presented.

  10. Destruction of Raman biosignatures by ionising radiation and the implications for life detection on Mars.

    Science.gov (United States)

    Dartnell, Lewis R; Page, Kristian; Jorge-Villar, Susana E; Wright, Gary; Munshi, Tasnim; Scowen, Ian J; Ward, John M; Edwards, Howell G M

    2012-04-01

    Raman spectroscopy has proven to be a very effective approach for the detection of microorganisms colonising hostile environments on Earth. The ExoMars rover, due for launch in 2018, will carry a Raman laser spectrometer to analyse samples of the martian subsurface collected by the probe's 2-m drill in a search for similar biosignatures. The martian surface is unprotected from the flux of cosmic rays, an ionising radiation field that will degrade organic molecules and so diminish and distort the detectable Raman signature of potential martian microbial life. This study employs Raman spectroscopy to analyse samples of two model organisms, the cyanobacterium Synechocystis sp. PCC 6803 and the extremely radiation resistant polyextremophile Deinococcus radiodurans, that have been exposed to increasing doses of ionising radiation. The three most prominent peaks in the Raman spectra are from cellular carotenoids: deinoxanthin in D. radiodurans and β-carotene in Synechocystis. The degradative effect of ionising radiation is clearly seen, with significant diminishment of carotenoid spectral peak heights after 15 kGy and complete erasure of Raman biosignatures by 150 kGy of ionising radiation. The Raman signal of carotenoid in D. radiodurans diminishes more rapidly than that of Synechocystis, believed to be due to deinoxanthin acting as a superior scavenger of radiolytically produced reactive oxygen species, and so being destroyed more quickly than the less efficient antioxidant β-carotene. This study highlights the necessity for further experimental work on the manner and rate of degradation of Raman biosignatures by ionising radiation, as this is of prime importance for the successful detection of microbial life in the martian near subsurface.

  11. Serum ionised calcium and cardiovascular disease in 45-years old men and women followed for 18 years

    DEFF Research Database (Denmark)

    Ogard, Christina Gerlach; Petersen, Janne; Jørgensen, Torben

    2006-01-01

    ) and a broader definition of CVD. Persons with ionised serum calcium in the highest quintile were compared with persons in the lower four quintiles. Results: In a univariate analysis persons with ionised serum calcium in the highest quintile had increased risk of IHD (p=0.001) and CVD (p=0.02) compared...

  12. Problems associated with the effects of low doses of ionising radiations

    International Nuclear Information System (INIS)

    Anon.

    1996-01-01

    This book is the English version of the report number 34 of the Academie des Sciences, published in October 1995, and entitled 'Problemes lies aux effets des faibles doses des radiations ionisantes'. This report had been endorsed by CODER (Comite des Etudes et Rapports) on February 7, 1995. In dealing with problems associated with ionising radiation, a wide range of important aspects must be taken into account and many different international bodies are concerned with them. It was therefore though useful to make the report available in English. Several additions have been made to the original edition: it has been complemented with three appendices on the cellular, molecular and genetic effects of exposure to low doses of ionising radiations ; it was though useful to give, in addition to the references of the chapters and appendices, a summary of the main relevant work published by French research teams over the past few years; an addendum quotes some of the important contributions made over the past year; a symposium devoted to the effects of low doses of ionising radiations, and to repair enzyme systems will be organized by the Academy at the end of 1997. This will provide the opportunity to re-explore the situation in the light of the data accumulated at that time. This field is evolving rapidly and a periodic evaluation of the new data is mandatory. (authors)

  13. Fracture propagation in gas pipelines - relevance to submarine lines

    Energy Technology Data Exchange (ETDEWEB)

    Fearnehough, G D [British Gas Corp., Newcastle upon Tyne. Engineering Research Station

    1976-09-01

    This paper reviews the factors which control fracture propagation in pipes and suggests how they are influenced by submarine environments. If fracture arrest capability is required then these factors should be considered in terms of the design philosophy and the maximum tolerable length of fracture which can be repaired. The paper shows that brittle fracture characteristics of submarine pipelines are probably similar to land based lines and fracture arrest can only be guaranteed by appropriate material toughness specification. Resistance to ductile fracture propagation in submarine lines is enhanced by lower design stresses, thicker pipe, concrete coating and the effect of hydrostatic head on gas dynamics. However, additional factors due to submarine design can be deleterious viz: uncertainty about backfill integrity and a tendency of thicker steels to low fracture resistance arising from 'separation' formation. Attention is drawn to problems which may arise with transportation of gases rich in hydrocarbons and the use of mechanical methods of fracture arrest.

  14. The line-emitting gas in active galaxies - A probe of the nuclear engine

    Science.gov (United States)

    Veilleux, Sylvain

    1993-01-01

    This paper reviews some of the basic questions regarding the structure of the engine powering active galactic nuclei (AGN), the nature of the interaction between the AGN and the host galaxy, and the origin and evolution of AGN. The study of the dynamics and physical characteristics of the line-emitting gas in these objects has proven fruitful in addressing many of these issues. Recent advances in optical and infrared detector technology combined with the development of superior ground-based instruments have produced efficient new tools for the study of the line-emitting gas on nuclear and Galactic scales. Programs which take advantage of two of these new techniques, Fabry-Perot imaging spectroscopy and infrared spectroscopy, are described in this paper. The origin of nuclear activity in galaxies is also addressed in a third project which aims at determining the nature of luminous infrared galaxies.

  15. International strategies for growth : monetizing gas reserves to add value to the bottom line

    International Nuclear Information System (INIS)

    Mihaichuk, G.

    1998-01-01

    The direction taken by oil and gas companies, including TransCanada International, in their strategy for growth in global energy markets was discussed. The role that gas plays in meeting the objectives was examined and the different ways in which gas reserves and investments in the gas sector are being turned into high-performing vehicles for adding value to the bottom line were described. Deregulation of, and competition within, the gas and electric power industries are the driving factors for changes within the energy industries. Natural gas will be a winner because it is the first choice for new power generation. Many companies have entered the international playing field to take advantage of the opportunities in international markets. The problems and solutions to monetizing natural gas reserves, some of the international political issues such as regulatory uncertainty, cross-border disputes, lack of regional integration, and sanctions, and how these adverse effects may be mitigated through mergers, acquisitions, or joint ventures, are explored. 14 figs

  16. Exploring the Powerful Ionised Wind in the Seyfert Galaxy PG1211+143

    Science.gov (United States)

    Pounds, Ken

    2013-10-01

    Highly-ionised high-speed winds in AGN (UFOs) were first detected with XMM-Newton a decade ago, and are now established as a key factor in the study of SMBH accretion, and in the growth and metal enrichment of their host galaxies. However, information on the ionisation and dynamical structure, and the ultimate fate of UFOs remains very limited. We request a 600ks extended XMM-Newton study of the prototype UFO PG1211+143 in AO-13, to obtain high quality EPIC and RGS spectra, to map the flow structure and variability, while seeking evidence for the anticipated interaction with the ISM and possible conversion of the energetic wind to a momentum-driven flow.

  17. Long term effects of low doses of ionising radiation: facts and fallacies

    International Nuclear Information System (INIS)

    Iyer, G.K.

    1993-01-01

    Health effects of low doses of ionising radiation have been a public concern. The public perception of these low effects is that it causes cancer and genetic effects. Enormous amount of work regarding this cancer has been done all over the world, on occupational workers exposed to low doses of ionising radiation. These studies do not show any adverse effect on them. Epidemiological studies done on members of public staying near nuclear facilities also have shown that there is no health risk involved in staying near these facilities. Genetic effects have also shown negative results. These two aspects of health effects of low dose of radiation are discussed in detail. (author). 5 refs., 1 tab

  18. Performance evaluation of synthetic diamond to realize ionisation chamber for radiotherapy application

    International Nuclear Information System (INIS)

    Guerrero Waryn, M.J.

    2005-09-01

    This work focuses on the optimisation of synthetic CVD diamond quality to realize ionisation chambers for radiotherapy. Diamonds samples have been synthesized and characterized using thermally stimulated measurement. These measurements showed the presence of trapping levels due to crystalline defects or impurities in material. The study of the response of these samples under irradiation has showed a correlation between the charged state of traps (priming and overshoot phenomena) and the response of the detector (stabilization of the signal). To remove the overshoot phenomenon which prevents from reproducible measurements, we used a specific operating set up controlling the device temperature. This technique enables to neutralize these instable phenomena and to use CVD diamond for ionisation chamber fabrication. (author)

  19. Non-targeted effects of ionising radiation—Implications for low dose risk

    DEFF Research Database (Denmark)

    Kadhim, Munira; Salomaa, Sisko; Wright, Eric

    2013-01-01

    and adaptive responses are powered by fundamental, but not clearly understood systems that maintain tissue homeostasis. Despite excellent research in this field by various groups, there are still gaps in our understanding of the likely mechanisms associated with non-DNA targeted effects, particularly......Non-DNA targeted effects of ionising radiation, which include genomic instability, and a variety of bystander effects including abscopal effects and bystander mediated adaptive response, have raised concerns about the magnitude of low-dose radiation risk. Genomic instability, bystander effects....... Furthermore, it is still not known what the initial target and early interactions in cells are that give rise to non-targeted responses in neighbouring or descendant cells. This paper provides a commentary on the current state of the field as a result of the non-targeted effects of ionising radiation (NOTE...

  20. Lactobacilli and ionising radiation: an example of the application to meat and meat products

    International Nuclear Information System (INIS)

    Holzapfel, W.H.

    1992-01-01

    Ionising radiation provides a practical pasteurisation method for the terminal treatment of refrigerated vacuum-packaged meat products with the aim of shelf life extension. However, the relatively high radiation resistance (γ-D 10 = 0.70-1.2 kGy) of typical meat Lactobacilli, especially Lb. sake, selectively favours their total domination after treatments with 5 kGy. Typical meat strains show higher resistance (in term of γ-D 10 values the decimal reduction value due to irradiation) in the log (exponential) than in the stationary phase. This phenomenon was observed both in semi-synthetic broth and in meat, and may be explained in terms of a DNA repair mechanism operative during the exponential phase. Packaging under different gas atmospheres resulted in increased resistance to radiation in presence of N 2 , whilst the highest death rate was observed in presence of CO 2 . (orig.) [de

  1. On-line valve monitoring at the Ormen Lange gas plant

    Energy Technology Data Exchange (ETDEWEB)

    Greenlees, R.; Hale, S. [Score Atlanta Inc., Kennesaw, Georgia (United States)

    2011-07-01

    The purpose of this presentation is to discuss replacing time and labor intensive nuclear outage activities with on line condition monitoring solutions, primarily the periodic verification of MOV functionality discussed in USNRC Generic Letter 96.05. This regulation requires that MOV age related performance degradations are properly identified and accounted for, causing utilities to have to retest valves periodically for the duration of the plants operating license. AECL designed CANDU reactors have a world class performance and safety record, with typical average annual capacity factors of 90%. The CANDU reactor design has the ability to refuel on line, as a result (a) it can be a challenge scheduling all required valve testing into limited duration outage work windows, (b) at multi unit sites, Unit 0 valves can be difficult to test because they are rarely ever out of service, (c) deuterium-oxide (heavy water) moderator is expensive to manufacture, as a result, effective through valve leakage monitoring is essential. These three factors alone make CANDU sites the most suitable candidates for on line valve monitoring systems. Nuclear industry regulations have been instrumental in the development of 'at the valve' diagnostic systems, but diagnostic testing has not typically been utilized to the same degree in other less regulated industries. However, that trend is changing, and the move toward valve diagnostics and condition monitoring has moved fastest in the offshore oil and gas industry on the Norwegian side of the North Sea. The Ormen Lange plant, located on Nyhamna Island on the west coast of Norway, operated by Shell, is one of the worlds most advanced gas processing plants. A stated maintenance goal for the plant is that 70% of the maintenance budget and spend should be based on the results of on line condition monitoring, utilizing monitoring systems equipped with switch sensing, strain gages, hydraulic and pneumatic pressure transducers and

  2. On-line valve monitoring at the Ormen Lange gas plant

    International Nuclear Information System (INIS)

    Greenlees, R.; Hale, S.

    2011-01-01

    The purpose of this presentation is to discuss replacing time and labor intensive nuclear outage activities with on line condition monitoring solutions, primarily the periodic verification of MOV functionality discussed in USNRC Generic Letter 96.05. This regulation requires that MOV age related performance degradations are properly identified and accounted for, causing utilities to have to retest valves periodically for the duration of the plants operating license. AECL designed CANDU reactors have a world class performance and safety record, with typical average annual capacity factors of 90%. The CANDU reactor design has the ability to refuel on line, as a result (a) it can be a challenge scheduling all required valve testing into limited duration outage work windows, (b) at multi unit sites, Unit 0 valves can be difficult to test because they are rarely ever out of service, (c) deuterium-oxide (heavy water) moderator is expensive to manufacture, as a result, effective through valve leakage monitoring is essential. These three factors alone make CANDU sites the most suitable candidates for on line valve monitoring systems. Nuclear industry regulations have been instrumental in the development of 'at the valve' diagnostic systems, but diagnostic testing has not typically been utilized to the same degree in other less regulated industries. However, that trend is changing, and the move toward valve diagnostics and condition monitoring has moved fastest in the offshore oil and gas industry on the Norwegian side of the North Sea. The Ormen Lange plant, located on Nyhamna Island on the west coast of Norway, operated by Shell, is one of the worlds most advanced gas processing plants. A stated maintenance goal for the plant is that 70% of the maintenance budget and spend should be based on the results of on line condition monitoring, utilizing monitoring systems equipped with switch sensing, strain gages, hydraulic and pneumatic pressure transducers and acoustic leakage

  3. The Coulomb deflection effect on the L3-subshell alignment in low-velocity proton impact ionisation

    International Nuclear Information System (INIS)

    Palinkas, J.; Schlenk, B.; Valek, A.

    1981-01-01

    The alignment parameter of the L 3 subshell of gold has been determined by measuring the angular distribution of the Lsub(l)/Lsub(γ) intensity ratio following proton impact ionisation in the 0.25-0.60 MeV energy range. The experimental results make it clear that the minimum of the alignment parameter at low energies found earlier for He + impact also exists in the case of proton impact ionisation. (author)

  4. Closing of Coster-Kronig transitions in multiply ionised gold atoms

    International Nuclear Information System (INIS)

    Banas, D.; Braziewicz, J.; Czarnota, M.; Fijal, I.; Jaskola, M.; Korman, A.; Kretschmer, W.; Pajek, M.; Semaniak, J.

    2003-01-01

    The paper discusses the effect of closing of L- and M-shell Coster-Kronig (CK) transitions in multiply ionised Au atoms, for which the selected CK transitions become energetically forbidden. This effect plays an important role when the Coster-Kronig energy for single-hole configuration is relatively low, being comparable with a change of the electronic binding energies in multiply ionised atom. We show, by using a simplified model, that for gold the effect of closing of CK transitions occurs for strong L 1 -L 3 M 4,5 transition for the L 1 -subshell as well as the M 3 -M 5 N 6,7 and M 4 -M 5 O 3,4 CK transitions for the M 3 - and M 4 -subshell, respectively. We demonstrate that the discussed effect of closing CK transitions substantially changes the X-ray fluorescence and Coster-Kronig yields and thus has to be considered in interpretation of X-rays excited by heavy ion impact

  5. Biological monitors for low levels of ionising radiation

    International Nuclear Information System (INIS)

    Mohankumar, M.N.; Jeevanram, R.K.

    1995-01-01

    The biological effects of high doses of ionising radiation are well understood and the methods of measurement of these doses well established. However the effects due to extremely low doses remain by and large uncertain. This is because of the fact that at such low doses no gross symptoms are seen. In fact, at these levels the occurrence of double strand breaks leading to the formation of chromosomal aberrations like dicentrics is rare and chances of mutation due to base damage are negligible. Hence neither chromosomal aberration studies nor mutational assays are useful for detecting doses of the order of a few milligray. Results of exhaustive work done by various laboratories indicate that below 20 mGy the chromosomal aberration technique based on scoring of dicentrics cannot distinguish between a linear or a threshold model. However indirect methods like unscheduled DNA synthesis (UDS) and sister chromatid exchanges (SCEs) appear to be promising for the detection of radiation exposures due to low levels of radiation. This report reviews the available literature on the biological effects of low levels of ionising radiation and highlights the merits and demerits of the various methods employed in the measurement of UDS and SCE. The phenomenon of radio-adaptive response (RAR) and its relation to DNA repair is also discussed. (author)

  6. Study and optimization of the ionisation channel in the Edelweiss dark matter direct detection experiment; Etude et optimisation de la voie ionisation dans l'experience Edelweiss de detection directe de la matiere noire

    Energy Technology Data Exchange (ETDEWEB)

    Censier, B

    2006-02-15

    The EDELWEISS experiment is aiming at the detection of Weakly Interactive Massive Particles (WIMPs), today's most favoured candidates for solving the dark matter issue. Background ionising particles are identified thanks to the simultaneous measurement of heat and ionisation in the detectors. The main limitation to this method is coming from the ionisation measurement, charge collection being less efficient in some part of the detectors known as 'dead' areas. The specificity of the measurement is due to the use of very low temperatures and low collection fields. This thesis is dedicated to the study of carrier trapping. It involves time-resolved charge measurements as well as a simulation code adapted to the specific physical conditions. We first present results concerning charge trapping at the free surfaces of the detectors. Our method allows to build a surface-charge in a controlled manner by irradiation with a strong radioactive source. This charge is then characterised with a weaker source which acts as a probe. In a second part of the work, bulk-trapping characteristics are deduced from charge collection efficiency measurements, and by an original method based on event localisation in the detector. The results show that a large proportion of the doping impurities are ionised, as indicated independently by the study of degradation by space-charge build-up. In this last part, near-electrodes areas are found to contain large densities of charged trapping centres, in connection with dead-layer effects. (author)

  7. Ionising radiation safety training in the Australian defence organisation (ADO)

    International Nuclear Information System (INIS)

    Jenks, G.J.; O'Donovan, E.J.B.; Wood, W.B.

    1996-01-01

    Full text: Training personnel in ionising radiation safety within the Australian Defence Organisation (ADO) requires addressing some unique features of an organisation employing both military and civilian personnel. Activities may include those of a civil nature (such as industrial and medical radiography), specific military requirements (for training and emergency response) and scientific research and development. Some personnel may be assigned to full-time duties associated with radiation, while others may be designated as radiation protection officers in remote units with few duties to perform in this role. A further complication is that most military personnel are subjected to postings at regular intervals. The ADO's Directorate of Defence Occupational Health and Safety has established an Ionising Radiation Safety Subcommittee to monitor not only the adequacy of the internal Ionising Radiation Safety Manual but also the training requirements. A training course, responding to these requirements, has been developed to emphasise: basic radiation theory and protection; operation of radiation monitors available in the ADO; an understanding of the Safety Manual; day-to-day radiation safety in units and establishments; and appropriate responses to radiation accidents and emergencies. In addition, students are briefed on a limited number of peripheral topics and participate in some site visits. Currently, two Courses are held annually, each with about twenty students. Most of the material is presented by ADO personnel with external contractor support. The three Courses held to date have proved sufficiently successful, both for the students and the ADO generally, to seek national accreditation through the Australian National Training Authority and, as a first step, competency standards have been identified

  8. Molecular Outflow and Feedback in an Obscured Quasar at z˜1.5 Revealed by ALMA

    Science.gov (United States)

    Brusa, Marcella

    2017-11-01

    We imaged with ALMA and ARGOS/LUCI the molecular gas and the dust and stellar continuum in XID2028, an obscured QSO at z=1.593, where the presence of a massive outflow in the ionized gas component traced by the [O III]5007 emission has been resolved up to 10 kpc. This target does represent a unique test case to study QSO 'feedback in action' at the peak epoch of AGN- galaxy coevolution. The QSO has been detected both in the CO(5-4) transition and in the 1.3mm continuum, with emissions confined in the central ( consumption conditions in XID2028, possibly due to feedback effects on the host galaxy. Finally, we observe an asymmetric profile of the CO(5-4) line, which suggests the presence of high velocity gas up to 700 km/s. An image of the blueshfited and redshifted CO wings provides the first detection of a spatially resolved, galaxy-scale molecular outflow at high-z, extended in opposite directions with the approaching component spatially coincident with the ionised gas outflow. The resolved, molecular outflow appear to be cospatial with the component observed int the ionised gas. XID2028 therefore represents the first example of molecular and ionised kpc scales outflows at high-z.

  9. Current-voltage characteristics of a gas field ion source with a supertip

    International Nuclear Information System (INIS)

    Boerret, R.; Boehringer, K.; Kalbitzer, S.

    1990-01-01

    The field ionisation properties of a supertip, a fine protrusion on top of a regular emitter, have been studied for hydrogen and the lighter rare gases. The parameter set included tip temperature, tip radius, gas temperature and gas pressure. Due to the local field enhancement at the supertip site, angular current intensities of 35 μA sr -1 and values of brightness up to 10 10 A cm -2 sr -1 have been obtained near the optimum temperature of the gas-tip system. At temperatures below this, the gas density reaches values typical for a condensed phase. In geometrical proportion, the regular tip area appears to serve as a gas supply for the supertip current. (author)

  10. Dynamics of ionisation and entanglement in the 'atom + quantum electromagnetic field' system

    Energy Technology Data Exchange (ETDEWEB)

    Sharapova, P R; Tikhonova, O V [Department of Physics, M.V. Lomonosov Moscow State University (Russian Federation)

    2012-03-31

    The dynamics of a model Rydberg atom in a strong nonclassical electromagnetic field is investigated. The field-induced transitions to the continuum involving different numbers of photons (with intermediate states in the discrete spectrum) are taken into account and the specific features of ionisation in 'squeezed' field states are considered in comparison with the case of classical light. A significant decrease in the ionisation rate is found, which is caused by the interference stabilisation of the atomic system. The entanglement of the atomic and field subsystems, the temporal dynamics of the correlations found, and the possibility of measuring them are analysed.

  11. Effects of self-similar correlations on the spectral line shape in the neutral gas

    International Nuclear Information System (INIS)

    Kharintsev, S.S.; Salakhov, M.Kh.

    2001-01-01

    The paper is devoted to the study of the influence of self-similar correlations on the Doppler and pressure broadening within the non-equilibrium Boltzmann gas. The diffuse model for the thermal motion of the radiator and the self-similar mechanism of interference of scalar perturbations for phase shifts of an atomic oscillator are developed. It is shown that taking into account self-similar correlation in a description of the spectral line shape allows one to explain, on the one hand, the additional spectral line Dicke-narrowing in the Doppler regime, and, on the other hand, the asymmetry in wings of the spectral line in a high pressure region

  12. Study and optimization of the ionisation channel in the Edelweiss dark matter direct detection experiment

    International Nuclear Information System (INIS)

    Censier, B.

    2006-02-01

    The EDELWEISS experiment is aiming at the detection of Weakly Interactive Massive Particles (WIMPs), today's most favoured candidates for solving the dark matter issue. Background ionising particles are identified thanks to the simultaneous measurement of heat and ionisation in the detectors. The main limitation to this method is coming from the ionisation measurement, charge collection being less efficient in some part of the detectors known as 'dead' areas. The specificity of the measurement is due to the use of very low temperatures and low collection fields. This thesis is dedicated to the study of carrier trapping. It involves time-resolved charge measurements as well as a simulation code adapted to the specific physical conditions. We first present results concerning charge trapping at the free surfaces of the detectors. Our method allows to build a surface-charge in a controlled manner by irradiation with a strong radioactive source. This charge is then characterised with a weaker source which acts as a probe. In a second part of the work, bulk-trapping characteristics are deduced from charge collection efficiency measurements, and by an original method based on event localisation in the detector. The results show that a large proportion of the doping impurities are ionised, as indicated independently by the study of degradation by space-charge build-up. In this last part, near-electrodes areas are found to contain large densities of charged trapping centres, in connection with dead-layer effects. (author)

  13. Ionising radiation: a guide to the Regulations

    International Nuclear Information System (INIS)

    Hughes, Donald.

    1986-01-01

    The author explains the basic requirements on health and safety personnel in relation to the Ionising Radiations Regulations 1985. The outline paper is presented under the following headings: Dose assessment, Interpretation and general regulations 1-5, Dose limitation regulations 6 and 7, Regulation of work - regulations 8-12, Dosimetry and medical surveillance - regulations 13-17, summary of records to be kept, entry to controlled areas, Control of radioactive substances -regulations 18-23, Monitoring of radiation regulation 24, Assessments and notifications - regulations 25-31, Safety of articles and equipment - regulations 32-34, Other guidance. (U.K.)

  14. Voxel anthropomorphic phantoms: review of models used for ionising radiation dosimetry

    International Nuclear Information System (INIS)

    Lemosquet, A.; Carlan, L. de; Clairand, I.

    2003-01-01

    Computational anthropomorphic phantoms have been used since the 1970's for dosimetric calculations. Realistic geometries are required for this operation, resulting in the development of ever more accurate phantoms. Voxel phantoms, consisting of a set of small-volume elements, appeared towards the end of the 1980's, and significantly improved on the original mathematical models. Voxel phantoms are models of the human body, obtained using computed tomography (CT) or magnetic resonance images (MRI). These phantoms are an extremely accurate representation of the human anatomy. This article provides a review of the literature available on the development of these phantoms and their applications in ionising radiation dosimetry. The bibliographical study has shown that there is a wide range of phantoms, covering various characteristics of the general population in terms of sex, age or morphology, and that they are used in applications relating to all aspects of ionising radiation. (author)

  15. EDDIX--a database of ionisation double differential cross sections.

    Science.gov (United States)

    MacGibbon, J H; Emerson, S; Liamsuwan, T; Nikjoo, H

    2011-02-01

    The use of Monte Carlo track structure is a choice method in biophysical modelling and calculations. To precisely model 3D and 4D tracks, the cross section for the ionisation by an incoming ion, double differential in the outgoing electron energy and angle, is required. However, the double differential cross section cannot be theoretically modelled over the full range of parameters. To address this issue, a database of all available experimental data has been constructed. Currently, the database of Experimental Double Differential Ionisation Cross sections (EDDIX) contains over 1200 digitalised experimentally measured datasets from the 1960s to present date, covering all available ion species (hydrogen to uranium) and all available target species. Double differential cross sections are also presented with the aid of an eight parameter functions fitted to the cross sections. The parameters include projectile species and charge, target nuclear charge and atomic mass, projectile atomic mass and energy, electron energy and deflection angle. It is planned to freely distribute EDDIX and make it available to the radiation research community for use in the analytical and numerical modelling of track structure.

  16. Gas inflow and outflow in an interacting high-redshift galaxy. The remarkable host environment of GRB 080810 at z = 3.35

    Science.gov (United States)

    Wiseman, P.; Perley, D. A.; Schady, P.; Prochaska, J. X.; de Ugarte Postigo, A.; Krühler, T.; Yates, R. M.; Greiner, J.

    2017-11-01

    We reveal multiple components of an interacting galaxy system at z ≈ 3.35 through a detailed analysis of the exquisite high-resolution Keck/HIRES spectrum of the afterglow of a gamma-ray burst (GRB). Through Voigt-profile fitting of absorption lines from the Lyman series, we constrain the neutral hydrogen column density to NH I ≤ 1018.35 cm-2 for the densest of four distinct systems at the host redshift of GRB 080810, which is among the lowest NH I ever observed in a GRB host, even though the line of sight passes within a projected 5 kpc of the galaxy centres. By detailed analysis of the corresponding metal absorption lines, we derive chemical, ionic, and kinematic properties of the individual absorbing systems, and thus build a picture of the host as a whole. Striking differences between the systems imply that the line of sight passes through several phases of gas: the star-forming regions of the GRB host; enriched material in the form of a galactic outflow; the hot and ionised halo of a second interacting galaxy falling towards the host at a line-of-sight velocity of 700 km s-1; and a cool metal-poor cloud that may represent one of the best candidates yet for the inflow of metal-poor gas from the intergalactic medium. The reduced spectrum is only available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (http://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/607/A107

  17. Electro-acoustic coupling in a plasma gas

    OpenAIRE

    Sutton, Yvonne

    2011-01-01

    Sound emission using an ionised medium has been the subject of research since the beginning of the 20th century. The mechanism involves modulation at an audio frequency of an electrically sustained plasma discharge. In a similar effect to lightning, the charged particles in the plasma respond to the varying energy input. With this comes gas heating, molecular excitation, light emission from relaxation of excited molecular states and acoustic emission resulting from thermal expansion within, a...

  18. Conversion of electromagnetic waves at the ionisation front

    International Nuclear Information System (INIS)

    Chegotov, M V

    2001-01-01

    It is shown that a weak electromagnetic pulse interacting with a copropagating ionisation front is converted in the general case into three electromagnetic pulses with higher and lower frequencies, which propagate in different directions. The coefficients of conversion to these pulses (for intensities) were found as functions of the frequency. The electromagnetic energy is shown to decrease during this conversion because of the losses for the residual electron energy. (interaction of laser radiation with matter. laser plasma)

  19. Gas chromatography at the Tritium Laboratory Karlsruhe

    International Nuclear Information System (INIS)

    Laesser, R.; Gruenhagen, S.

    2003-08-01

    Among the analytical techniques (mass spectrometry, laser Raman spectroscopy, gas chromatography, use of ionisation chambers) employed at the Tritium Laboratory Karlsruhe (TLK), gas chromatography plays a prominent role. The main reasons for that are the simplicity of the gas chromatographic separation process, the small space required for the equipment, the low investment costs in comparison to other methods, the robustness of the equipment, the simple and straightforward analysis and the fact that all gas species of interest (with the exception of water) can easily be detected by gas chromatographic means. The conventional gas chromatographs GC1 and GC2 used in the Tritium Measurement Techniques (TMT) System of the TLK and the gas chromatograph GC3 of the experiment CAPER are presented in detail, by discussing their flow diagrams, their major components, the chromatograms measured by means of various detectors, shortcomings and possible improvements. One of the main disadvantages of the conventional gas chromatography is the long retention times required for the analysis of hydrogen gas mixtures. To overcome this disadvantage, micro gas chromatography for hydrogen analysis was developed. Reduction of the retention times by one order of magnitude was achieved. (orig.)

  20. On plasma-neutral gas interaction

    International Nuclear Information System (INIS)

    Venkataramani, N.; Mattoo, S.K.

    1980-01-01

    The importance of plasma-neutral gas interaction layer has been emphasized by pointing out its application to a wide variety of physical phenomena. The interaction of a magnetised plasma stream penetrating a neutral gas cloud is discussed in the light of Alfven's critical velocity and Varma's threshold velocity on the ionising interaction. Interaction of a moving magnetised plasma with a stationary neutral gas has been studied and described. The device comprises of a plasma gun and an interaction region where neutral gas cloud is injected. The interaction region is provided with a transverse magnetic field of upto 1000 G. Several diagnostics deployed at the interaction region to make measurements on the macroscopic parameters of plasma and neutral gas are described. The parameters of discharge circuits are measured with high current and voltage probes. An interaction between a magnetised plasma stream and a neutral gas cloud is demonstrated. It is shown that this interaction does not have Varma's threshold on their relative velocity. The Alfven's critical velocity phenomenon is shown to depend on the integrated column neutral gas density that a plasma stream encounters while penetrating through it and not on the neutral gas density in the range of 10 17 -10 21 m -3 . (auth.)

  1. Ion pair production and chemi-ionisation in collisions of He*(2sup(1,3)S) with Li

    International Nuclear Information System (INIS)

    Wang, D.P.; Tang, S.Y.; Neynaber, R.H.

    1987-01-01

    A merging-beams technique has been used to study collisions of He*(2sup(1,3)S) with Li. The He* represents a composite of 13% He(2 1 S) and 87% He(2 3 S). Absolute and relative cross sections, Q, have been measured in a range of relative kinetic energy, W, from 150 to 1500 eV for the ion pair production (IPP) of He + + Li - , and from 0.01 to 500 eV for chemi-ionisation (CI). Information obtained for CI shows that: the Penning ionisation reaction is directed with most of the Li + scattered in the incident Li direction, the He*-Li system is attractive with a measured well depth of 0.73 eV and the value of Q for total ionisation varies as Wsup(-0.34). Similarities to the He*-He* system are also given. (author)

  2. Nonlinear collisionless electron cyclotron interaction in the pre-ionisation stage

    Science.gov (United States)

    Farina, D.

    2018-06-01

    Electron cyclotron (EC) wave-particle interaction is theoretically investigated in the pre-ionisation phase, much before collisions and other mechanisms can play a role. In the very first phase of a plasma discharge with EC-assisted breakdown, the motion of an electron at room temperature in a static magnetic field under the action of a localised microwave beam is nonlinear, and transition to states of larger energy can occur via wave trapping. Within a Hamiltonian adiabatic formalism, the conditions at which the particles gain energy in single beam crossing are derived in a rigorous way, and the energy variation is characterized quantitatively as a function of the wave frequency, harmonic number, polarisation and EC power and beam width. Estimates of interest for applications to tokamak start-up are obtained for the first, second and third cyclotron harmonic. The investigation confirms that electrons can easily gain energies well above the ionisation energy in most conditions at the first two harmonics, while not at the third harmonic, as observed in experiments.

  3. Intercomparison of radon gas detectors 1997 at PSI

    International Nuclear Information System (INIS)

    Schuler, Christoph; Butterweck-Dempewolf, Gernot

    1998-05-01

    Between Nov 14 and Nov 20, 1997, the Reference Laboratory for Radon Gas Activity Concentration Measurements at Paul Scherrer Institut performed the 1997 Radon Intercomparison Exercise. Radon gas detectors and instruments were exposed in the PSI Radon Chamber during seven days in a reference atmosphere with an average radon gas concentration of 3860 Bqm -3 . The majority of the participants at this intercomparison were Swiss Radon Gas Measurement Laboratories acknowledged by the Swiss Federal Office for Health. Criteria for this acknowledgement are a deviation of the measurement results to the reference value below 15% (traceability criterion) and a standard deviation of the mean of five detector measurement results below 15% (reproducibility criterion). With the exception of three participants, the results of electret ionisation chambers, track etch detectors and measuring instruments fulfilled the demanded traceability and reproducibility criteria. (author)

  4. Evaluation of cytogenetic damage in nuclear medicine personnel occupationally exposed to low-level ionising radiation

    International Nuclear Information System (INIS)

    Garaj-Vrhovac, V.; Kopjar, N.; Poropat, M.

    2005-01-01

    Despite intensive research over the last few decades, there still remains considerable uncertainty as to the genetic impact of ionising radiation on human populations, particularly at low levels. The aim of this study was to provide data on genetic hazards associated with occupational exposure to low doses of ionising radiation in nuclear medicine departments. The assessment of DNA damage in peripheral blood lymphocytes of medical staff was performed using the chromosome aberration (CA) test. Exposed subjects showed significantly higher frequencies of CA than controls. There were significant inter-individual differences in DNA damage within the exposed population, indicating differences in genome sensitivity. Age and gender were not confounding factors, while smoking enhanced the levels of DNA damage only in control subjects. The present study suggests that chronic exposure to low doses of ionising radiation in nuclear medicine departments causes genotoxic damage. Therefore, to avoid potential genotoxic effects, the exposed medical personnel should minimise radiation exposure wherever possible. Our results also point to the significance of biological indicators providing information about the actual risk to the radiation exposed individuals.(author)

  5. Veterinary applications of ionising radiation HERCA Task Force on Veterinary Applications. Main results of the Questionnaire 'National regulatory requirements with regard to veterinary medical applications of ionising radiation' and conclusions of the TF

    International Nuclear Information System (INIS)

    Van Bladel, Lodewijk; Berlamont, Jolien; Michalczak, Herbert; Balogh, Lajos; Peremans, Kathelijne

    2013-11-01

    In the fall of 2012, the subject of radiation protection in veterinary medicine was raised during the meeting of the HERCA Board. Issues with regard to this subject had been brought to the attention of HERCA by the European College of Veterinary Diagnostic Imaging (ECVDI). In October 2012, the Board decided to charge a small Task Force (TF) to further explore the issues in this field. This TF drew up a questionnaire which looked at the general radiation protection regulatory requirements in veterinary medicine applications of ionizing radiation. The results of this study showed large differences in the requirements applicable in the HERCA member countries. The TF also noticed the increasing use of more complex imaging procedures and of different radio-therapeutic modalities, which may imply greater risks of exposure of humans to ionising radiation. These results were presented during the HERCA Board meeting in Berlin, Germany and on which the Board decided to establish a Working Group on veterinary applications of ionising radiations (WG Vet). The main results of the Questionnaire 'National regulatory requirements with regard to veterinary medicine applications of ionising radiation' is attached in Appendix

  6. Electron impact ionisation cross sections of iron oxides

    Science.gov (United States)

    Huber, Stefan E.; Mauracher, Andreas; Sukuba, Ivan; Urban, Jan; Maihom, Thana; Probst, Michael

    2017-12-01

    We report electron impact ionisation cross sections (EICSs) of iron oxide molecules, FexOx and FexOx+1 with x = 1, 2, 3, from the ionisation threshold to 10 keV, obtained with the Deutsch-Märk (DM) and binary-encounter-Bethe (BEB) methods. The maxima of the EICSs range from 3.10 to 9 . 96 × 10-16 cm2 located at 59-72 eV and 5.06 to 14.32 × 10-16 cm2 located at 85-108 eV for the DM and BEB approaches, respectively. The orbital and kinetic energies required for the BEB method are obtained by employing effective core potentials for the inner core electrons in the quantum chemical calculations. The BEB cross sections are 1.4-1.7 times larger than the DM cross sections which can be related to the decreasing population of the Fe 4s orbitals upon addition of oxygen atoms, together with the different methodological foundations of the two methods. Both the DM and BEB cross sections can be fitted excellently to a simple analytical expression used in modelling and simulation codes employed in the framework of nuclear fusion research. Supplementary material in the form of one pdf file available from the Journal web page at http://https://doi.org/10.1140/epjd/e2017-80308-2.

  7. Biological monitors for low levels of ionising radiation

    Energy Technology Data Exchange (ETDEWEB)

    Mohankumar, M N; Jeevanram, R K [Safety Research and Health Physics Group, Indira Gandhi Centre for Atomic Research, Kalpakkam (India)

    1996-12-31

    The biological effects of high doses of ionising radiation are well understood and the methods of measurement of these doses well established. However the effects due to extremely low doses remain by and large uncertain. This is because of the fact that at such low doses no gross symptoms are seen. In fact, at these levels the occurrence of double strand breaks leading to the formation of chromosomal aberrations like dicentrics is rare and chances of mutation due to base damage are negligible. Hence neither chromosomal aberration studies nor mutational assays are useful for detecting doses of the order of a few milligray. Results of exhaustive work done by various laboratories indicate that below 20 mGy the chromosomal aberration technique based on scoring of dicentrics cannot distinguish between a linear or a threshold model. However indirect methods like unscheduled DNA synthesis (UDS) and sister chromatid exchanges (SCEs) appear to be promising for the detection of radiation exposures due to low levels of radiation. This report reviews the available literature on the biological effects of low levels of ionising radiation and highlights the merits and demerits of the various methods employed in the measurement of UDS and SCE. The phenomenon of radio-adaptive response (RAR) and its relation to DNA repair is also discussed. (author). 98 refs., 11 figs., 4 tabs.

  8. Double ionisation of helium in fast ion collisions: the role of momentum transfer

    International Nuclear Information System (INIS)

    Bapat, B.; Moshammer, R.; Schmitt, W.; Kollmus, H.; Ullrich, J.; Doerner, R.; Weber, T.; Khayyat, K.

    1999-01-01

    Double ionisation of helium in the perturbative regime has been explored in a kinematically complete collision experiment using 100 MeV/u C 6+ ions. Different ionisation mechanisms are identified by inspecting the angular distribution of the electrons as a function of the momentum transfer q to the target by the projectile. For q 1.2 a.u., the faster electron resulting from a binary encounter with the projectile is emitted along the direction of momentum transfer, while the other electron is distributed uniformly. Experimental data are compared with various model calculations based on the Bethe-Born approximation with shake-off. Surprisingly, the effect of the final state interaction is found to depend decisively on the choice of the initial state wave function. (orig.)

  9. Rapid detection of nicotine from breath using desorption ionisation on porous silicon.

    Science.gov (United States)

    Guinan, T M; Abdelmaksoud, H; Voelcker, N H

    2017-05-04

    Desorption ionisation on porous silicon (DIOS) was used for the detection of nicotine from exhaled breath. This result represents proof-of-principle of the ability of DIOS to detect small molecular analytes in breath including biomarkers and illicit drugs.

  10. Ionised media and fractures: application to cartilaginous tissues and oil industry

    NARCIS (Netherlands)

    Huyghe, J.M.R.J.; Kraaijeveld, F.; Remmers, J.J.C.; Borst, de R.; Denier, J; Finn, M.D.; Mattner, T

    2008-01-01

    ionized media are ubiquitous in nature. Our body holds onto water through ionised macromolecules that bind water up to a 1000 times their own mass. Clays and shales do a similar trick in the geoworld. Localization of deformation and fractures are very common. Bore hole instability through fracture

  11. Operation of low-noise single-gap RPC modules exposed to ionisation rates up to 1 kHz/cm$^2$

    CERN Document Server

    Cwiok, M; Dominik, Wojciech; Górski, M; Królikowski, J; 10.1016/j.nima.2004.06.123

    2004-01-01

    Two single gap medium-size RPC modules, made of bakelite plates of very good mechanical quality of the surface and having initial volume resistivity of 1 multiplied by 10**1**0 omegacm, were tested in the Gamma Irradiation Facility at CERN at ionisation rates up to 1 kHz/cm **3. The internal surfaces facing the gas volume of one RPC module were cladded with a thin layer of linseed oil varnish for comparison of oiled and non-oiled RPC operation. The results refer to the gas mixture of C//2H//2F //4/isobutane (97:3) with SF//6 addition below 1%. The single gap modules exhibited full detection efficiency plateau for the high voltage range of about 1 kV at full intensity of gamma rays. Good timing characteristics allowed to reach 95% efficiency at fully opened irradiation source with time window of 20 ns. The intrinsic noise rate for a non-oiled and an oiled RPC gap was, respectively, below 5 and 1 Hz/cm**2 at full efficiency over 1 k V voltage range.

  12. Production of radioactive ion beams and resonance ionization spectroscopy with the laser ion source at on-line isotope separator ISOLDE

    International Nuclear Information System (INIS)

    Fedosseev, V.N.; )

    2005-01-01

    Full text: The resonance ionisation laser ion source (RILIS) of the ISOLDE on-line isotope separation facility at CERN is based on the method of laser step-wise resonance ionisation of atoms in a hot metal cavity. Using the system of dye lasers pumped by copper vapour lasers the ion beams of many different metallic elements have been produced at ISOLDE with an ionization efficiency of up to 27%. The high selectivity of the resonance ionization is an important asset for the study of short-lived nuclides produced in targets bombarded by the proton beam of the CERN Booster accelerator. Radioactive ion beams of Be, Mg, Al, Mn, Ni, Cu, Zn, Ga, Ag, Cd, In, Sn, Sb, Tb, Yb, Tl, Pb and Bi have been generated with the RILIS. Setting the RILIS laser in the narrow line-width mode provides conditions for a high-resolution study of hyperfine structure and isotopic shifts of atomic lines for short-lived isotopes. The isomer selective ionization of Cu, Ag and Pb isotopes has been achieved by appropriate tuning of laser wavelengths

  13. Eddy covariance flux measurements of ammonia by high temperature chemical ionisation mass spectrometry

    Directory of Open Access Journals (Sweden)

    J. Sintermann

    2011-03-01

    Full Text Available A system for fast ammonia (NH3 measurements with chemical ionisation mass spectrometry (CIMS based on a commercial Proton Transfer Reaction-Mass Spectrometer (PTR-MS is presented. It uses electron transfer reaction as ionisation pathway and features a drift tube of polyetheretherketone (PEEK and silica-coated steel. Heating the instrumental inlet and the drift tube to 180 °C enabled an effective time resolution of ~1 s and made it possible to apply the instrument for eddy covariance (EC measurements. EC fluxes of NH3 were measured over two agricultural fields in Oensingen, Switzerland, following fertilisations with cattle slurry. Air was aspirated close to a sonic anemometer at a flow of 100 STP L min−1 and was directed through a 23 m long 1/2" PFA tube heated to 150 °C to an air-conditioned trailer where the gas was sub-sampled from the large bypass stream. This setup minimised damping of fast NH3 concentration changes between the sampling point and the actual measurement. High-frequency attenuation loss of the NH3 fluxes of 20 to 40% was quantified and corrected for using an empirical ogive method. The instrumental NH3 background signal showed a minor interference with H2O which was characterised in the laboratory. The resulting correction of the NH3 flux after slurry spreading was less than 1‰. The flux detection limit of the EC system was about 5 ng m−2 s−1 while the accuracy of individual flux measurements was estimated 16% for the high-flux regime during these experiments. The NH3 emissions after broad spreading of the slurry showed an initial maximum of 150 μg m−2 s−1 with a fast decline in the following hours.

  14. Reactors Dynamic analysis Due to Reactivity of The RSG-Gas at One Line Cooling Mode

    International Nuclear Information System (INIS)

    Hastuti, Endiah Puji

    2003-01-01

    In the frame of minimizing the operation-cost, operation mode using one line cooling system is being evaluated. Maximum reactor power has been determined and steady state and LOFA transient analysis have also been done. To complete those analyses, the reactivity analysis was done by means of a core dynamic and thermal hydraulic code, PARET-ANL. Accident simulation was done. by a ramp reactivity accident due to control rod withdrawal. Reactivity analysis was carried out at two power range i.e. low and high power level, by imposing one line mode reactor protection limits. The results show that technically, the RSG-Gas can be operated safely using one line mode

  15. International responsability of state by the deleterius effects of ionising radiation

    International Nuclear Information System (INIS)

    Faria, N.M. de.

    1988-01-01

    International Responsability of State, considering the deleterius effects of ionising radiation on the human being, property, territory and environment which are under other jurisdiction, is focused. Conventional rules, costumary rules, the evolution of ''opinion juris'' as well as the decisions of tribunals related to the subject are analysed. (author) [pt

  16. Injuries to embryo and foetus from ionising radiation

    International Nuclear Information System (INIS)

    Devik, F.

    1980-01-01

    A brief review is given of experimental and clinical evidence for tetatological effects of ionising radiation, against the background of general teratology. International and national recommendations and regulations for the protection of the conceptus are quoted. As to interruption of a pregnancy following an unintended exposure, it is pointed out that much of the present evidence points to a dose in the order of 0.1Gy (10 rads) as a dose which may be considered as a practical threshold for the induction of congenital defects. (Auth.)

  17. Evaluation of chromosomal aberrations in radiologists and medical radiographers chronically exposed to ionising radiation

    International Nuclear Information System (INIS)

    Kasuba, V.; Rozgaj, R.; Jazbec, A.

    2005-01-01

    Chromosomal aberrations are fairly reliable indicators of damage induced by ionising radiation. This study included 180 radiologists and medical radiographers (technicians) and 90 controls who were not occupationally exposed to ionising radiation. All exposed subjects were routinely monitored with film badge, and none was exposed to a radiation dose exceeding the limit for occupational exposure recommended by the International Commission on Radiological Protection (ICRP). Two hundred metaphases for each person were scored. The frequencies of acentric fragments, dicentrics, ring chromosomes and chromosomal exchanges were determined and compared to those obtained in the control group. Chromosome aberrations were analysed using Poisson regression for profession, age, sex, smoking and years of exposure. Age, smoking, diagnostic exposure to X-rays and occupation were found to correlate with the occurrence of acentric fragments. The influence of exposure duration on the frequency of acentric fragments was greater in medical radiographers than in radiologists. Smoking and sex were found to correlate with the occurrence of dicentric chromosomes, which were more common in men than in women. As chromosome aberrations exceeded the expected level with respect to the absorbed dose, our findings confirm the importance of chromosome analysis as a part of regular medical check-up of subjects occupationally exposed to ionising radiation.(author)

  18. Improved determination of flavour compounds in butter by solid-phase (micro)extraction and comprehensive two-dimensional gas chromatography

    NARCIS (Netherlands)

    Adahchour, M.; Wiewel, J.; Verdel, R.; Vreuls, R.J.J.; Brinkman, U.A.T.

    2005-01-01

    The practicability and potential of comprehensive two-dimensional gas chromatography (GC × GC) coupled to both conventional flame ionisation (FID) and time-of-flight mass spectrometric (TOF-MS) detection, were compared with those of conventional one-dimensional (1D) GC, with the determination of

  19. On-Line Fission Gas Release Monitoring System in the High Flux Reactor Petten

    International Nuclear Information System (INIS)

    Laurie, M.; Fuetterer, M. A.; Appelman, K.H.; Lapetite, J.-M.; Marmier, A.; Knol, S.; Best, J.

    2013-06-01

    For HTR fuel irradiation tests in the HFR Petten a specific installation was designed and installed dubbed the 'Sweep Loop Facility' (SLF). The SLF is tasked with three functions, namely temperature control by gas mixture technique, surveillance of safety parameters (temperature, pressure, radioactivity etc.) and analysis of fission gas release for three individual capsules in two separate experimental rigs. The SLF enables continuous and independent surveillance of all gas circuits. The release of volatile fission products (FP) from the in-pile experiments is monitored by continuous gas purging. The fractional release of these FP, defined as the ratio between release rate of a gaseous fission isotope (measured) to its instantaneous birth rate (calculated), is a licensing-relevant test for HTR fuel. The developed gamma spectrometry station allows for higher measurement frequencies, thus enabling follow-up of rapid and massive release transients. The designed stand-alone system was tested and fully used through the final irradiation period of the HFR-EU1 experiment which was terminated on 18 February 2010. Its robustness allowed the set up to be used as extra safety instrumentation. This paper describes the gas activity measurement technique based on HPGe gamma spectrometry and illustrates how qualitative and quantitative analysis of volatile FP can be performed on-line. (authors)

  20. The use of ionising radiation screening devices in airports

    International Nuclear Information System (INIS)

    Lazo, T.

    2010-01-01

    Although the NEA generally focuses on radiological protection at nuclear power plants and related facilities, it also addresses other areas of radiological protection of interest to member countries. A particular subject of recent importance concerns the use of ionising radiation screening devices as part of airport security efforts. Modern body scanners can produce human images that can be used to detect weapons that may be hidden beneath a person's clothing. Heightened concerns over terrorist threats to airline flights have prompted many countries to consider the use, or expanded use of body scanners. The use of such devices raises a wide series of questions, some of which concern the radiological protection of those who might be scanned. As such, the Inter-Agency Committee on Radiation Safety (IACRS), an expert body in which the NEA works together with several other international organisations addressing radiological protection issues, recently developed a joint information paper laying out the key radiological protection and other issues that should be or have been considered when making decisions as to whether ionising radiation body scanners should be deployed in airports. This article provides an overview of the information paper. In assessing the possible use of X-ray body scanners, there are two significant radiological protection issues that may be of relevance with regard to the government decision whether their use is justified. First, although the individual exposures are very low, the exposure experienced by the scanned population as a whole will depend on whether all passengers are systematically scanned, or alternatively whether passengers are selected for scanning randomly or on the basis of specific criteria. The manner in which passengers would be selected would need to be known in order to appropriately assess the full radiological protection impact of scanner use. Second, the use of X-ray body scanners on sensitive groups, such as pregnant

  1. Use of ionising radiation

    International Nuclear Information System (INIS)

    1988-11-01

    The Committee has inquired into and reported on the use of ionising radiation for commercial sterilisation, disinfestation, food preservation and other purposes with particular reference to human health and safety; environmental impacts, and adequacy of assessment and regulatory procedures. While food irradiation is apparently commercially successful overseas the application to Australia seems extremely limited - it would be used primarily for disinfestation of insect pests and perhaps to reduce levels of harmful bacteria in a limited range of foods. For other applications there are effective and more economic alternatives. The report reviews other studies of food irradiation and the policies and practices governing its use in other countries. The safety of irradiated food, the radiological safety issues and the regulations which would be required in Australia are dealt with in detail. The Committee recommends, inter alia, that the Australian Government should not approve the irradiation of food in Australia until such time as a routine commercial method of detection has been developed and that the import of caesium 137 for use as an irradiation source in commercial irradiation facilities be prohibited

  2. Laser absorption spectroscopy of water vapor confined in nanoporous alumina: wall collision line broadening and gas diffusion dynamics.

    Science.gov (United States)

    Svensson, Tomas; Lewander, Märta; Svanberg, Sune

    2010-08-02

    We demonstrate high-resolution tunable diode laser absorption spectroscopy (TDLAS) of water vapor confined in nanoporous alumina. Strong multiple light scattering results in long photon pathlengths (1 m through a 6 mm sample). We report on strong line broadening due to frequent wall collisions (gas-surface interactions). For the water vapor line at 935.685 nm, the HWHM of confined molecules are about 4.3 GHz as compared to 2.9 GHz for free molecules (atmospheric pressure). Gas diffusion is also investigated, and in contrast to molecular oxygen (that moves rapidly in and out of the alumina), the exchange of water vapor is found very slow.

  3. Beam Dynamics in a Muon Ionisation Cooling Channel

    International Nuclear Information System (INIS)

    Rogers, Chris

    2008-01-01

    The Neutrino Factory has been proposed as a facility to provide an intense source of neutrinos suitable for the measurement of neutrino oscillation parameters and a possible CP violating phase to unprecedented precision. In the Neutrino Factory, neutrinos are produced by the decay of a muon beam with 20-50 GeV per muon. Initially, the muon beam occupies a large volume in phase space, which must be reduced before the beam can be accelerated. The proposed method to achieve this is to use a solenoidal ionisation colling channel.

  4. Use of ionising radiation for food processing applications

    International Nuclear Information System (INIS)

    Ninjoor, V.

    1989-01-01

    Food irradiation is a recently developed technique used to sterilize and preserve food. Food products are exposed to ionising radiations such as X-rays, gamma rays or high energy electrons which destroy food borne pathogens and parasites and inhibit sprouting. Shelf life of food is extended. The following aspects of radiation processing of food are discussed in the monograph: radiation sources, choice of dose for specific results, safety and nutritional quality of radiation processed food, international status of acceptance of food irradiation, and cost. (M.G.B.). 6 tabs

  5. An electromagnetic field measurement protocol for monitoring power lines

    International Nuclear Information System (INIS)

    Lubritto, C.; Iavazzo, A.; D'Onofrio, A.; Palmieri, A.; Sabbarese, C.; Terrasi, F.

    2002-01-01

    In the actions aiming to prevent risks related to the exposure to Low Frequencies Non Ionising electromagnetic Radiations (ELF-NIR), always arises the need to perform measurements in order to assess the field level existing in the considered sites. As a matter of fact very often it turns out difficult to predict, on the base of calculations, with sufficient approximation the field levels, due to extended variability of environmental conditions (e.g. coexistence of several sources, ground and building conformation, etc..). The measurement procedures must follow a methodology that could allow to minimise the interferences with the measurement set-up and the systematic and accidental errors. Risks for the operator and damages to the instrument should also be taken into account. One of the goal set for this research program was then the definition of the measurement protocol for electromagnetic field generated by low frequency non ionising radiation sources. In particular sources like power lines will be considered in order to validate the protocol by means of in-field measurements

  6. Study of micro-strip gas ionisation chambers substrates for CMS experiment at LHC

    International Nuclear Information System (INIS)

    Pallares, A.

    1996-01-01

    High luminosity, expected interaction and dose rates of the future LHC collider require the development of micro-strips gas chambers. In addition to optimization of this new detector, this work is concerned with understanding of gain loss phenomena. Influence of the gas substrate is carefully analysed, as well as theoretical concepts concerning glasses and their behaviour under polarization and irradiation, and the consequence on detection operations.Electron spin resonance is used to study, in standard glass, creation of radiation induced defects which may be charged. (D.L.)

  7. Basic radiation chemistry for the ionising energy treatment of food

    International Nuclear Information System (INIS)

    Moore, P.W.

    1985-01-01

    Before we can understand the chemistry involved in the irradiation of complex substances such as food we need to have some appreciation of the reactions involved and the products formed when ionising energy interacts with the simple substances such as water and dilute solutions. Reactions involving hydrated electrons, hydrogen atoms and hydroxyl radicals are examined and methods for minimising radiolytic effects in foods are discussed

  8. Nodalization Preparation for the Transient Simulation of Cooling System for One Line Mode of RSG-GAS

    International Nuclear Information System (INIS)

    Sukmanto Dibyo; Susyadi; Tagor MS; Darwis Isnaeni

    2004-01-01

    Cooling system is important component in RSG-GAS. To carry out the transient simulation of one line-cooling mode, the model of RSG-GAS has been prepared. To illustrate the transient condition, the RELAP5.MOD3 computer code the existing input files were used. This Input consist of kinetic, thermal, hydraulic and geometries data. Modification and decrement of number of nodalization has been done to simplification as well as running time. The reasonable result of model is arranged to determine the initial condition of input data therefore steady state condition have agreement to the analysis result of one line cooling mode of RSG-GAS. Parameter investigated are transient temperatures of cooling system after decreasing of secondary cooling system occur as function of time. These parameters can be requested using input of Minor Edit Request Simulation is conducted at the reactor power of 15 MW steady-state for one-line cooling mode in which the primary and secondary cooling of 430 kg/sec and 550 kg/sec respectively. Decreasing of secondary cooling flow is caused by pump trip. As a consequence, the control rod drop due to reactor protection system. The negative reactivity of control rod causes decreasing of reactor power. Change of pattern for the primary and secondary cooling system can be known. After that simulation depicts that increasing of temperatures occur at the certain moment since initiation temperature conditions, due to reactor shut down, curve inclined move going down. (author)

  9. Two-dimensional readout in a liquid xenon ionisation chamber

    CERN Document Server

    Solovov, V; Ferreira-Marques, R; Lopes, M I; Pereira, A; Policarpo, Armando

    2002-01-01

    A two-dimensional readout with metal strips deposited on both sides of a glass plate is investigated aiming to assess the possibility of its use in a liquid xenon ionisation chamber for positron emission tomography. Here, we present results obtained with an alpha-source. It is shown that position resolution of <=1 mm, fwhm, can be achieved for free charge depositions equivalent to those due to gamma-rays with energy from 220 down to 110 keV.

  10. Kinematically complete study on electron impact ionisation of aligned hydrogen molecules

    Energy Technology Data Exchange (ETDEWEB)

    Senftleben, Arne

    2009-10-28

    Within the work presented here, single ionisation of spatially aligned hydrogen molecules by 200 eV electrons was studied in a kinematically complete experiment. For the first time, a comprehensive set of fully differential cross sections (FDCS) was obtained for this process on a molecular target. The direction of the internuclear axis was derived from the fragment emission of post-collision dissociation of the residual H{sub 2}{sup +} ion. Therefore, a protonic fragment was detected in coincidence with the two final-state electrons using a dedicated reaction microscope and sophisticated data analysis. For direct ionisation into the ionic ground state, existing theoretical cross sections for aligned molecules were tested. Additionally, we observed molecular frame angular distributions of Auger electrons emitted through dissociative autoionisation of H{sub 2}. Earlier findings of kinematically incomplete experiments were reproduced, but the FDCS reveal structures so far unknown. Furthermore, for random alignment, differential cross sections at two distinct values of the mean internuclear distance were obtained, providing new arguments in the current discussion on the nature of discrepancies observed between atomic and molecular collisions. (orig.)

  11. Towards a Symmetric Momentum Distribution in the Muon Ionisation Cooling Experiment

    CERN Document Server

    Hansen, O M; Efthymiopoulos, I

    2013-01-01

    TheMuon Ionisation Cooling Experiment (MICE) is under development at Rutherford Appleton Labratory (UK). It is a proof-of-principle experiment for ionisation cooling, which is a prerequisite for a future Neutrino Factory (NF) or a Muon Collider. The muon beam will have a symmetrical momentum distribution in the cooling channel of theNF [1]. In the MICE beamline pions are captured by a quadrupole triplet, beam momentum is selected by dipole 1 (D1) before the beam traverses the decay solenoid. After the decay solenoid the beam momentum is selected by dipole 2 (D2), the beam is focused in two quadrupole triplets and characterised by time-of-flight (TOF) detectors TOF0 and TOF1 before entering the cooling channel. By doing a so-called D1-scan, where the optics parameters are scaled according to the upstream beam momentum, the purity and momentum distribution of the decay muons are changed. In this paper simulation results from G4Beamline (G4BL) [2] and data from MICE are presented and compared.

  12. Fitness of equipment used for medical exposures to ionising radiation

    International Nuclear Information System (INIS)

    1998-01-01

    The advice in this guidance note is aimed at employers in control of equipment used for medical exposures to ionising radiation and ancillary equipment. This includes NHS trusts, health authorities or boards, private hospitals, clinics, surgeries, medical X-ray facilities in industry, dentists and chiropractors. The guidance should also be useful to radiation protection advisers appointed by such employers. The guidance provides advice on the requirements of regulation 33 of the Ionising Radiations Regulations 1985 (IRR85). In particular, it covers: (a) the selection, installation, maintenance, calibration and replacement of equipment to ensure that it is capable of restricting, so far as reasonably practicable, the medical exposure of any person to the extent that this is compatible with the intended diagnostic or therapeutic purpose; (b) recommended procedures for the definitive calibration of radiotherapy treatment; and (c) the need to investigate incidents involving a malfunction or defect in any 'radiation equipment' which result in medical exposures much greater than intended and to notify the Health and Safety Executive (HSE). 'Medical exposure' is defined in IRR85 as exposure of a person to ionising radiation for the purpose of his or her medical or dental examination or treatment which is conducted under the direction of a suitably qualified person and includes any such examination or treatment conducted for the purposes of research. For convenience, people undergoing medical exposure will be referred to as 'patients' in this guidance. Nothing in this publication is intended to indicate whether or not patients should be informed of any incident resulting from malfunction or defect in equipment used for medical exposure and the possible consequences of that exposure. As stated above, this guidance concerns medical exposures much greater than intended and although exposures much lower than intended can also have serious consequences, the incident would not

  13. Experimental determination of pcav factors for cylindrical ionisation chambers in electron beams

    International Nuclear Information System (INIS)

    Palm, Aa.; Mattsson, O.

    2000-01-01

    The electron beam method recommended for calibrating plane parallel ionisation chambers involves cavity correction factors for cylindrical chambers. The cavity correction factors in the IAEA TRS-381 Code of Practice are based on measurements at R 100 in a PMMA phantom using PMMA cylindrical chambers having different cavity radii. In the present work the recommended data were confirmed for electron beams delivered by modern medical accelerators by using the very same phantom and ionisation chambers that were used in the original work. From another series of measurements, using four specially designed wall-less chambers in a graphite phantom, the linear relation between p cav and the chamber radius that is the basis for the experimental method, was verified. The method was also used to determine the cavity correction factors for a set of Farmer-like graphite chambers placed in water. Compared to the TRS-381 Code of Practice a smaller correction was found for the cavity perturbation for the graphite chambers used in water. (author)

  14. Chapter 8. Ionisation radiation and human organism. Radioactivity of human tissues

    International Nuclear Information System (INIS)

    Toelgyessy, J.; Harangozo, M.

    2000-01-01

    This is a chapter of textbook of radioecology for university students. In this chapter authors deal with ionisation radiation and human organism as well as with radioactivity of human tissues. Chapter consists of next parts: (1) Radiation stress of human organism; (2) Radioactivity of human tissues and the factors influencing radioactive contamination; (3) Possibilities of decreasing of radiation stress

  15. Exposure of the French paediatric population to ionising radiation from diagnostic medical procedures in 2010

    International Nuclear Information System (INIS)

    Etard, Cecile; Aubert, Bernard; Mezzarobba, Myriam; Bernier, Marie-Odile

    2014-01-01

    Medical examination is the main source of artificial radiation exposure. Because children present an increased sensitivity to ionising radiation, radiology practices at a national level in paediatrics should be monitored. This study describes the ionising radiation exposure from diagnostic medical examinations of the French paediatric population in 2010. Data on frequency of examinations were provided by the French National Health Insurance through a representative sample including 107,627 children ages 0-15 years. Effective doses for each type of procedure were obtained from the published French literature. Median and mean effective doses were calculated for the studied population. About a third of the children were exposed to at least one examination using ionising radiation in 2010. Conventional radiology, dental exams, CT scans and nuclear medicine and interventional radiology represent respectively 55.3%, 42.3%, 2.1% and 0.3% of the procedures. Children 10-15 years old and babies from birth to 1 year are the most exposed populations, with respectively 1,098 and 734 examinations per 1,000 children per year. Before 1 year of age, chest and pelvis radiographs are the most common imaging tests, 54% and 32%, respectively. Only 1% of the studied population is exposed to CT scan, with 62% of these children exposed to a head-and-neck procedure. The annual median and mean effective doses were respectively 0.03 mSv and 0.7 mSv for the exposed children. This study gives updated reference data on French paediatric exposure to medical ionising radiation that can be used for public health or epidemiological purposes. Paediatric diagnostic use appears much lower than that of the whole French population as estimated in a previous study. (orig.)

  16. Exposure of the French paediatric population to ionising radiation from diagnostic medical procedures in 2010

    Energy Technology Data Exchange (ETDEWEB)

    Etard, Cecile; Aubert, Bernard [Institut de Radioprotection et de Surete Nucleaire, Medical Expertise Unit, Fontenay-aux-Roses (France); Mezzarobba, Myriam [Institut de Radioprotection et de Surete Nucleaire, Laboratory of Epidemiology, Fontenay-aux-Roses (France); Bernier, Marie-Odile [Institut de Radioprotection et de Surete Nucleaire, Laboratory of Epidemiology, Fontenay-aux-Roses (France); Institut de Radioprotection et de Surete Nucleaire, IRSN/PRP-HOM/SRBE/LEPID, Laboratoire d' Epidemiologie, Fontenay-aux-Roses (France)

    2014-12-15

    Medical examination is the main source of artificial radiation exposure. Because children present an increased sensitivity to ionising radiation, radiology practices at a national level in paediatrics should be monitored. This study describes the ionising radiation exposure from diagnostic medical examinations of the French paediatric population in 2010. Data on frequency of examinations were provided by the French National Health Insurance through a representative sample including 107,627 children ages 0-15 years. Effective doses for each type of procedure were obtained from the published French literature. Median and mean effective doses were calculated for the studied population. About a third of the children were exposed to at least one examination using ionising radiation in 2010. Conventional radiology, dental exams, CT scans and nuclear medicine and interventional radiology represent respectively 55.3%, 42.3%, 2.1% and 0.3% of the procedures. Children 10-15 years old and babies from birth to 1 year are the most exposed populations, with respectively 1,098 and 734 examinations per 1,000 children per year. Before 1 year of age, chest and pelvis radiographs are the most common imaging tests, 54% and 32%, respectively. Only 1% of the studied population is exposed to CT scan, with 62% of these children exposed to a head-and-neck procedure. The annual median and mean effective doses were respectively 0.03 mSv and 0.7 mSv for the exposed children. This study gives updated reference data on French paediatric exposure to medical ionising radiation that can be used for public health or epidemiological purposes. Paediatric diagnostic use appears much lower than that of the whole French population as estimated in a previous study. (orig.)

  17. Investigation of damage mechanism by ionising radiation on biomolecules

    International Nuclear Information System (INIS)

    Lau How Mooi

    1996-01-01

    Occupational radiation hazard is a very controversial subject. Effects from high radiation doses are well known from past experiences. However, hazard from low doses is still a subject that is hotly debated upon until now. The occupational dosimetry used now is based on a macroscopic scale. Lately, microdosimetry is fast gaining recognition as a more superior way of measuring hazard. More importantly, scientists are researching the basic damage mechanism that leads to biological effects by ionising radiation. In this report, a simulation study of the basic damage mechanism is discussed . This simulation is based upon Monte Carlo calculations and using polyuridylic acid (Poly-U) as the DNA model This simulation tries to relate the physics and chemistry of interactions of ionising radiation with biomolecules. The computer codes used in this simulation, OREC and RADLYS were created by Hamm et al. (1983) in Oak Ridge National Laboratory. The biological endpoints in this simulation are the strand break and base release of the DNA, which is the precursor of all biological effects. These results are compared with model studies that had been done experimentally to check the validity of this simulation. The G-values of strand break and base release from this simulation were -2.35 and 2.75 and compared well with results from irradiation experiments by von Sonntag (I 98 7) from Max Plank's Institute, Germany

  18. Search for ionisation density effects in the radiation absorption stage in LiF:Mg,Ti

    International Nuclear Information System (INIS)

    Nail, I.; Horowitz, Y. S.; Oster, L.; Brandan, M. E.; Rodriguez-Villafuerte, M.; Buenfil, A. E.; Ruiz-Trejo, C.; Gamboa-deBuen, I.; Avila, O.; Tovar, V. M.; Olko, P.; Ipe, N.

    2006-01-01

    Optical absorption (OA) dose-response of LiF:Mg,Ti (TLD-100) is studied as a function of electron energy (ionisation density) and irradiation dose. Contrary to the situation in thermoluminescence dose-response where the supra-linearity is strongly energy-dependent, no dependence of the OA dose filling constants on energy is observed. This result is interpreted as indicating a lack of competitive process in the radiation absorption stage. The lack of an energy dependence of the dose filling constant also suggests that the charge carrier migration distances are sufficiently large to smear out the differences in the non-uniform distribution of ionisation events created by the impinging gamma/ electron radiation of various energies. (authors)

  19. A dual-phase xenon TPC for scintillation and ionisation yield measurements in liquid xenon

    Science.gov (United States)

    Baudis, Laura; Biondi, Yanina; Capelli, Chiara; Galloway, Michelle; Kazama, Shingo; Kish, Alexander; Pakarha, Payam; Piastra, Francesco; Wulf, Julien

    2018-05-01

    A small-scale, two-phase (liquid/gas) xenon time projection chamber ( Xurich II) was designed, constructed and is under operation at the University of Zürich. Its main purpose is to investigate the microphysics of particle interactions in liquid xenon at energies below 50 keV, which are relevant for rare event searches using xenon as target material. Here we describe in detail the detector, its associated infrastructure, and the signal identification algorithm developed for processing and analysing the data. We present the first characterisation of the new instrument with calibration data from an internal ^83{m} Kr source. The zero-field light yield is 15.0 and 14.0 photoelectrons/keV at 9.4 and 32.1 keV, respectively, and the corresponding values at an electron drift field of 1 kV/cm are 10.8 and 7.9 photoelectrons/keV. The charge yields at these energies are 28 and 31 electrons/keV, with the proportional scintillation yield of 24 photoelectrons per one electron extracted into the gas phase, and an electron lifetime of 200 μ s. The relative energy resolution, σ /E, is 11.9 and 5.8% at 9.4 and 32.1 keV, respectively using a linear combination of the scintillation and ionisation signals. We conclude with measurements of the electron drift velocity at various electric fields, and compare these to literature values.

  20. Molecular gas in the Herschel-selected strongly lensed submillimeter galaxies at z 2-4 as probed by multi-J CO lines

    Science.gov (United States)

    Yang, C.; Omont, A.; Beelen, A.; Gao, Y.; van der Werf, P.; Gavazzi, R.; Zhang, Z.-Y.; Ivison, R.; Lehnert, M.; Liu, D.; Oteo, I.; González-Alfonso, E.; Dannerbauer, H.; Cox, P.; Krips, M.; Neri, R.; Riechers, D.; Baker, A. J.; Michałowski, M. J.; Cooray, A.; Smail, I.

    2017-12-01

    We present the IRAM-30 m observations of multiple-J CO (Jup mostly from 3 up to 8) and [C I](3P2 → 3P1) ([C I](2-1) hereafter) line emission in a sample of redshift 2-4 submillimeter galaxies (SMGs). These SMGs are selected among the brightest-lensed galaxies discovered in the Herschel-Astrophysical Terahertz Large Area Survey (H-ATLAS). Forty-seven CO lines and 7 [C I](2-1) lines have been detected in 15 lensed SMGs. A non-negligible effect of differential lensing is found for the CO emission lines, which could have caused significant underestimations of the linewidths, and hence of the dynamical masses. The CO spectral line energy distributions (SLEDs), peaking around Jup 5-7, are found to be similar to those of the local starburst-dominated ultra-luminous infrared galaxies and of the previously studied SMGs. After correcting for lensing amplification, we derived the global properties of the bulk of molecular gas in the SMGs using non-LTE radiative transfer modelling, such as the molecular gas density nH2 102.5-104.1 cm-3 and the kinetic temperature Tk 20-750 K. The gas thermal pressure Pth ranging from 105 K cm-3 to 106 K cm-3 is found to be correlated with star formation efficiency. Further decomposing the CO SLEDs into two excitation components, we find a low-excitation component with nH2 102.8-104.6 cm-3 and Tk 20-30 K, which is less correlated with star formation, and a high-excitation one (nH2 102.7-104.2 cm-3, Tk 60-400 K) which is tightly related to the on-going star-forming activity. Additionally, tight linear correlations between the far-infrared and CO line luminosities have been confirmed for the Jup ≥ 5 CO lines of these SMGs, implying that these CO lines are good tracers of star formation. The [C I](2-1) lines follow the tight linear correlation between the luminosities of the [C I](2-1) and the CO(1-0) line found in local starbursts, indicating that [C I] lines could serve as good total molecular gas mass tracers for high-redshift SMGs as well

  1. An on-line gas control system using an artificial intelligence language: PROLOG II

    International Nuclear Information System (INIS)

    Lai, C.

    1990-01-01

    An application of Artificial Intelligence to a real physics experiment is presented. This allows comparison with classical programming techniques. The PROLOG language appears as a convenient on-line language, easily interfaced to the low level service routines, for which algorithmic languages can still be used. Steering modules have been written for a gas acquisition and analysis program, and for a control system with graphic human interface. This system includes safety rules and automatic action sequences

  2. Not to confuse 'contaminated' food and 'irradiated' or 'ionised' food

    International Nuclear Information System (INIS)

    2005-01-01

    Food contamination corresponds to the undesired presence of radioactive products in food, while irradiation is a process to which food can be deliberately submitted to improve its preservation or hygiene. This publication explains this difference. It describes the process, physical effects and health impacts of radioactive contamination of food. It briefly describes irradiation or ionisation processes, their objectives, doses of ionising radiations used on food products, undesired and harmful effects. It also indicates food products concerned by these irradiation processes, and the associated legal framework, evokes the lack of information of consumers regarding such practices, briefly evokes risks associated with irradiation installations, and indicates where these installations are located in France

  3. Measurement of air kerma rates for 6- to 7-MeV high-energy gamma-ray field by ionisation chamber and build-up plate.

    Science.gov (United States)

    Kowatari, Munehiko; Tanimura, Yoshihiko; Tsutsumi, Masahiro

    2014-12-01

    The 6- to 7-MeV high-energy gamma-ray calibration field by the (19)F(p, αγ)(16)O reaction is to be served at the Japan Atomic Energy Agency. For the determination of air kerma rates using an ionisation chamber in the 6- to 7-MeV high-energy gamma-ray field, the establishment of the charged particle equilibrium must be achieved during measurement. In addition to measurement of air kerma rates by the ionisation chamber with a thick build-up cap, measurement using the ionisation chamber and a build-up plate (BUP) was attempted, in order to directly determine air kerma rates under the condition of regular calibration for ordinary survey meters and personal dosemeters. Before measurements, Monte Carlo calculations were made to find the optimum arrangement of BUP in front of the ionisation chamber so that the charged particle equilibrium could be well established. Measured results imply that air kerma rates for the 6- to 7-MeV high-energy gamma-ray field could be directly determined under the appropriate condition using an ionisation chamber coupled with build-up materials. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Characteristics of a gas-jet transport system for an on-line isotope separator

    International Nuclear Information System (INIS)

    Kawade, K.; Yamamoto, H.; Amano, H.; Hanada, M.; Katoh, T.; Okano, K.; Kawase, Y.; Fujiwara, I.

    1982-01-01

    Basic characteristics of a gas-jet transport system for an on-line isotope separator have been investigated using a 252 Cf source and a 235 U fission source. The transport efficiency of fission products through a capillary has been measured to be about 60% for the 235 U fission source. The sweep-out time of fission products through a target chamber and the transit time through a capillary have been measured for He, N 2 and CO 2 gases at several pressures. The measured sweep-out times have been almost equal to the exchange over time of the gas. The transit times have been found to be reasonably predicted by calculations. The transport system has been incorporated into the KUR-ISOL and is used for the study of short-lived nuclei. (orig.)

  5. The K-shell ionisation of atoms by relativistic protons

    International Nuclear Information System (INIS)

    Davidovic, D.M.; Moiseiwitsch, B.L.; Norrington, P.H.

    1978-01-01

    The K-shell ionisation of atoms by protons travelling with relativistic velocities is investigated using an extension of the first-order time-dependent perturbation-theory treatment of Moeller (Ann. Phys. Lpz.; 14:531 (1932)), taking Dirac plane waves for the description of the incident and scattered protons and the Darwin approximation for the relativistic wavefunctions of the K-shell atomic electrons and the ejected electron. The differential cross sections and total cross sections are calculated. Results are compared with those of earlier workers. (author)

  6. Gas market distorting effects of imbalanced gas balancing rules: Inefficient regulation of pipeline flexibility

    International Nuclear Information System (INIS)

    Keyaerts, Nico; Hallack, Michelle; Glachant, Jean-Michel; D'haeseleer, William

    2011-01-01

    This paper analyzes the value and cost of line-pack flexibility in liberalized gas markets through examination of the techno-economic characteristics of gas transport pipelines and the trade-offs between different ways to use the infrastructure: transport and flexibility. Line-pack flexibility is becoming increasingly important as a tool to balance gas supply and demand over different periods. In the European liberalized market context, a monopolist unbundled network operator offers regulated transport services and flexibility (balancing) services according to the network code and balancing rules. Therefore, gas policy makers should understand the role and consequences of line-pack regulation. The analysis shows that the line-pack flexibility service has an important economic value for the shippers and the TSO. Furthermore, the analysis identifies distorting effects in the gas market due to inadequate regulation of line-pack flexibility: by disregarding the sunk costs of flexibility in the balancing rules, the overall efficiency of the gas system is decreased. Finally, the analysis demonstrates that the actual costs of line-pack flexibility are related to the peak cumulative imbalance throughout the balancing period. Any price for pipeline flexibility should, therefore, be based on the related trade-off between the right to use the line-pack flexibility and the provision of transport services. - Research Highlights: →Line-pack flexibility is a main gas balancing instrument. →Capacity related costs of line-pack flexibility depend on peak cumulative imbalances. →Line-pack pricing rules determine choice between ex ante and ex post balancing. →Inefficient line-pack regulation causes gas market distortions.

  7. Commercial potential of natural gas storage in lined rock caverns (LRC)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-11-01

    The geologic conditions in many regions of the United States will not permit the development of economical high-deliverability gas storage in salt caverns. These regions include the entire Eastern Seaboard; several northern states, notably Minnesota and Wisconsin; many of the Rocky Mountain States; and most of the Pacific Northwest. In late 1997, the United States Department of Energy (USDOE) Federal Energy Technology Center engaged Sofregaz US to investigate the commercialization potential of natural gas storage in Lined Rock Caverns (LRC). Sofregaz US teamed with Gaz de France and Sydkraft, who had formed a consortium, called LRC, to perform the study for the USDOE. Underground storage of natural gas is generally achieved in depleted oil and gas fields, aquifers, and solution-mined salt caverns. These storage technologies require specific geologic conditions. Unlined rock caverns have been used for decades to store hydrocarbons - mostly liquids such as crude oil, butane, and propane. The maximum operating pressure in unlined rock caverns is limited, since the host rock is never entirely impervious. The LRC technology allows a significant increase in the maximum operating pressure over the unlined storage cavern concept, since the gas in storage is completely contained with an impervious liner. The LRC technology has been under development in Sweden by Sydkraft since 1987. The development process has included extensive technical studies, laboratory testing, field tests, and most recently includes a storage facility being constructed in southern Sweden (Skallen). The LRC development effort has shown that the concept is technically and economically viable. The Skallen storage facility will have a rock cover of 115 meters (375 feet), a storage volume of 40,000 cubic meters (250,000 petroleum barrels), and a maximum operating pressure of 20 MPa (2,900 psi). There is a potential for commercialization of the LRC technology in the United States. Two regions were studied

  8. Calculated ionisation potentials to determine the oxidation of vanillin precursors by lignin peroxidase.

    NARCIS (Netherlands)

    Have, ten R.; Rietjens, I.M.C.M.; Hartmans, S.; Swarts, H.J.; Field, J.A.

    1998-01-01

    In view of the biocatalytic production of vanillin, this research focused on the lignin peroxidase (LiP) catalysed oxidation of naturally occurring phenolic derivatives: O-methyl ethers, O-acetyl esters, and O-glucosyl ethers. The ionisation potential (IP) of a series of model compounds was

  9. The effect of an alternating electric field on a totally ionised plasma; Action d'un champ electrique alternatif sur un plasma totalement ionise

    Energy Technology Data Exchange (ETDEWEB)

    Baglin, H; Brin, A; Ozias, Y; Salmon, J [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires; Delcroix, J L [Ecole Normale Superieure, 75 - Paris (France)

    1960-07-01

    The equation giving the distribution function of the electrons in a steady-state, for a fully ionized plasma in an a.c. field, are provided from the Fokker-Planck equation. The electric conductivity is complex and depends on the frequency. (author) [French] L'equation qui donne la fonction de distribution des electrons dans un etat stationnaire pour un plasma totalement ionise dans un champ electrique alternatif est fournie par l'equation de Fokker-Planck. La conductibilite electrique est complexe et depend de la frequence. (auteur)

  10. Effects of intense stratospheric ionisation events

    International Nuclear Information System (INIS)

    Reid, G.C.; McAfee, J.R.; Crutzen, P.J.

    1978-01-01

    High levels of ionising radiation in the Earth's stratosphere will lead to increased concentrations of nitrogen oxides and decreased concentrations of ozone. Changes in the surface environment will include an increased level, of biologically harmful UV radiation, caused by the ozone depletion, and a decreased level of visible solar radiation, due to the presence of major enhancements in the stratospheric concentration of nitrogen dioxide. These changes have been studied quantitatively, using the passage of the Solar System through a supernova remnant shell as an example. Some of the potential environmental changes are a substantial global cooling, abnormally dry conditions, a reduction in global photosynthesis and a large increase in the flux of atmospheric fixed nitrogen to the surface of the Earth. Such events might have been the cause of mass extinctions in the distant past. (Author)

  11. Bolivia-Brazil gas line route detailed

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This paper reports that state oil companies of Brazil and Bolivia have signed an agreement outlining the route for a 2,270 km pipeline system to deliver natural gas from Bolivian fields to Southeast Brazil. The two sides currently are negotiating details about construction costs as well as contract volumes and prices. Capacity is projected at 283-565 MMcfd. No official details are available, but Roberto Y. Hukai, a director of the Sao Paulo engineering company Jaako Poyry/Technoplan, estimates transportation cost of the Bolivian gas at 90 cents/MMBTU. That would be competitive with the price of gas delivered to the Sao Paulo gas utility Comgas, he the. Brazil's Petroleos Brasileiro SA estimates construction of the pipeline on the Brazilian side alone with cost $1.2-1.4 billion. Bolivia's Yacimientos Petroliferos Fiscales Bolivianos (YPFB) is negotiating with private domestic and foreign investors for construction of the Bolivian portion of the project

  12. Experimental investigation of the utilisation of ionisation gauges for leak detection

    CERN Document Server

    Benvenuti, C

    1972-01-01

    A description is given of a method of leak detecting applicable to the ISR (CERN) vacuum system after bakeout. This method, based on the enhanced indication of an ionisation gauge obtained when replacing the air around the leak by Argon, affords a detection efficiency not lower than that obtainable by means of a traditional leak detector; furthermore it does not introduce contamination risks after bakeout. (4 refs).

  13. Guideline for the licensing of various designs of ionisation smoke alarms

    International Nuclear Information System (INIS)

    1978-01-01

    The purpose of the guideline is to set up criteria for the construction licensing of ionisation smoke alarms and to determine their use. This guarantees that only those ISA are licensed which correspond to the level of science and technology and that the ISA to be licensed fulfills the demands of radiation protection. The recommendations of OECD/NEA are also born in mind. (orig./HP) [de

  14. The 2008 intercomparison exercise for radon gas measurement instruments at PSI; Die Vergleichsmessung 2008 fuer Radongasmessgeraete am PSI

    Energy Technology Data Exchange (ETDEWEB)

    Butterweck, G.; Schuler, Ch.; Mayer, S.

    2010-09-15

    Sixteen radon measurement services participated in the 2008 Radon Intercomparison Exercise performed at the Reference Laboratory for Radon Gas Activity Concentration Measurements at the Paul Scherrer Institute (PSI) during August 28{sup th} to September 7{sup th}, 2008 on behalf of the Swiss Federal Office of Public Health (FOPH). Twelve of these laboratories were approved by the FOPH and their participation in the intercomparison exercise was a requirement to warrant quality of measurement. Radon gas dosemeters (etched-track, electronic and electret ionisation chambers) and instruments (ionization chambers) were exposed in the PSI Radon Chamber in a reference atmosphere with an average radon gas concentration of 627 Bq m{sup -3} leading to a radon gas exposure of 155 kBq h m{sup -3}. One measuring instrument participating for testing purposes stored values for part of the exposure interval (30.8. - 7.9.2008). The exposure during this partial interval was 117 kBq h m{sup -3} at an average radon gas concentration of 624 Bq m{sup -3}. The exposure of 155 kBq h m{sup -3} was the lowest used at the PSI intercomparisons down to the present day. Especially the LLT electret ionisation chambers used by some of the laboratories reached the lower end of their measurement range with this exposure. Unexpected deviations of instruments of the same model seem to show a dependence on the serial number and thus production date. (authors)

  15. Hot gas in the interstellar medium, from supernova remnants to the diffuse coronal phase

    International Nuclear Information System (INIS)

    Ballet, Jean

    1988-01-01

    This research thesis addresses the study of the hot interstellar medium and of its main component, supernovae remnants. The author studied the hypothesis according to which ions observed in the interstellar medium are produced during the evaporation of cold clouds in the coronal phase. He shows that effects of ionisation delay are important and modify by a factor 10 the total quantity of ions predicted by the model. The study of the influence on ionisation of hot electrons penetrating cold layers revealed that this effect is rather weak. Then, based on the observation of the Kepler supernovae remnants by means of EXOSAT, and on the use of a hydrodynamics code coupled with a step-by-step calculation of ionisation of elements, the author studied the evolution of young supernovae remnants: propagation of the main shock in the interstellar medium, and of the backlash in the matter ejected by the star. The author also studied the X emission of an older supernovae remnant (the Cygnus Loop) by analysing three EXOSAT observations of this remnant. Results of Fabry-Perot spectrophotometry have been used to study optic lines [fr

  16. The philosophy and assumptions underlying exposure limits for ionising radiation, inorganic lead, asbestos and noise

    International Nuclear Information System (INIS)

    Akber, R.

    1996-01-01

    Full text: A review of the literature relating to exposure to, and exposure limits for, ionising radiation, inorganic lead, asbestos and noise was undertaken. The four hazards were chosen because they were insidious and ubiquitous, were potential hazards in both occupational and environmental settings and had early and late effects depending on dose and dose rate. For all four hazards, the effect of the hazard was enhanced by other exposures such as smoking or organic solvents. In the cases of inorganic lead and noise, there were documented health effects which affected a significant percentage of the exposed populations at or below the [effective] exposure limits. This was not the case for ionising radiation and asbestos. None of the exposure limits considered exposure to multiple mutagens/carcinogens in the calculation of risk. Ionising radiation was the only one of the hazards to have a model of all likely exposures, occupational, environmental and medical, as the basis for the exposure limits. The other three considered occupational exposure in isolation from environmental exposure. Inorganic lead and noise had economic considerations underlying the exposure limits and the exposure limits for asbestos were based on the current limit of detection. All four hazards had many variables associated with exposure, including idiosyncratic factors, that made modelling the risk very complex. The scientific idea of a time weighted average based on an eight hour day, and forty hour week on which the exposure limits for lead, asbestos and noise were based was underpinned by neither empirical evidence or scientific hypothesis. The methodology of the ACGIH in the setting of limits later brought into law, may have been unduly influenced by the industries most closely affected by those limits. Measuring exposure over part of an eight hour day and extrapolating to model exposure over the longer term is not the most effective way to model exposure. The statistical techniques used

  17. 78 FR 33403 - Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental...

    Science.gov (United States)

    2013-06-04

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PF13-5-000] Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental Assessment for the Planned Leidy Southeast Expansion Project, Request for Comments on Environmental Issues, and Notice of Public Scoping Meetings The staff of the Federal...

  18. 77 FR 59391 - Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental...

    Science.gov (United States)

    2012-09-27

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. CP12-497-000] Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental Assesment for the Proposed Brandywine Creek Replacement Project; Request for Comments on Environmental Issues; and Notice of Public Scoping Meeting The staff of the Federal...

  19. 75 FR 42738 - Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental...

    Science.gov (United States)

    2010-07-22

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PF10-16-000] Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental Assessment for the Planned Mid-Atlantic Connector Expansion Project, Request for Comments on Environmental Issues, and Notice of Public Scoping Meeting July 15, 2010. The...

  20. Collection efficiency of charges in ionization chambers in presence of constant or variable radiation intensity; Efficacite de la collection des charges dans les chambres d'ionisation en presence d'une intensite de rayonnement ionisant constante ou variable

    Energy Technology Data Exchange (ETDEWEB)

    Decuyper, J [Commissariat a l' Energie Atomique, Grenoble (France). Centre d' Etudes Nucleaires

    1970-07-01

    The theoretical and experimental study of the collection of carriers built up by ionization in standard chambers, is made by varying the value of different acting parameters. In the presence of constant ionization intensity and under a D.C. and A.C. voltage, the effect of geometry, recombination, diffusion and attachment is analyzed. The compensation of thermal neutron D.C. chambers is equally considered. Under a time dependent ionization intensity and D.C. voltage, is then studied the effect of recombination on current response, and on the collection efficiency of all formed charges. (author) [French] L'etude theorique et experimentale de la collection des porteurs crees par ionisation dans les chambres couramment utilisees est entreprise en fonction de la valeur des differents parametres agissants. En presence d'une ionisation constante et sous une tension d'alimentation d'abord continue puis alternative, on analyse l'influence de la geometrie, de la recombinaison, de la diffusion et de l'attachement. La compensation des chambres a courant continu de mesure neutronique est egalement examinee. Ensuite, sous une intensite d'ionisation variable dans le temps et en alimentation continue, on etudie l'effet de la recombinaison sur la reponse en courant et sur l'efficacite de la collection de la charge totale liberee. (auteur)

  1. A New Radio Spectral Line Survey of Planetary Nebulae: Exploring Radiatively Driven Heating and Chemistry of Molecular Gas

    Science.gov (United States)

    Bublitz, Jesse

    Planetary nebulae contain shells of cold gas and dust whose heating and chemistry is likely driven by UV and X-ray emission from their central stars and from wind-collision-generated shocks. We present the results of a survey of molecular line emissions in the 88 - 235 GHz range from nine nearby (Radioastronomie Millimetrique. Rotational transitions of nine molecules, including the well-studied CO isotopologues and chemically important trace species, were observed and the results compared with and augmented by previous studies of molecular gas in PNe. Lines of the molecules HCO+, HNC, HCN, and CN, which were detected in most objects, represent new detections for five planetary nebulae in our study. Flux ratios were analyzed to identify correlations between the central star and/or nebular ultraviolet/X-ray luminosities and the molecular chemistries of the nebulae. Analysis reveals the apparent dependence of the HNC/HCN line ratio on PN central star UV luminosity. There exists no such clear correlation between PN X-rays and various diagnostics of PN molecular chemistry. The correlation between HNC/HCN ratio and central star UV luminosity hints at the potential of molecular emission line studies of PNe for improving our understanding of the role that high-energy radiation plays in the heating and chemistry of photodissociation regions.

  2. Documentation of Occupational Accidents and Diseases caused by Ionising Radiation

    International Nuclear Information System (INIS)

    Fehringer, F.; Seitz, G.

    2004-01-01

    . One of the major goals of the institutions for statutory accident insurance is the prevention of occupational diseases. To perform a successful prevention work it is necessary not only to count the number of accidents or diseases in the various working fields but to look for details of the conditions of work and the human response to those conditions. The institutions for statutory accident insurance have engaged the institution for statutory accident insurance in the precision engineering and electrical industry to carry out documentation, in form of a data bank, for all cases of occupational diseases which could be caused by ionising radiation. Those are not only the cases which are accepted as occupational disease but also the cases where a suspicion of an occupational disease is announced but finally rejected. At the moment about 1700 cases are included in the data bank. For preserving the anonymity information to name and residence are deleted. Various data to one single case are linked by a case-specific key-number. Information to occupation and field of working, to details of a possible exposure to ionising radiation like kind of radiation, time and duration of radiation, exposure of the whole body or of parts of the body and whole body or organ doses are collected. Additional information refers to medical aspects like diagnosis and date of diagnosis. (Author)

  3. Analysis of oak tannins by liquid chromatography-electrospray ionisation mass spectrometry.

    Science.gov (United States)

    Mämmelä, P; Savolainen, H; Lindroos, L; Kangas, J; Vartiainen, T

    2000-09-01

    Extractable tannins were analysed by liquid chromatography-electrospray ionisation mass spectrometry in two oak species, North American white oak (Quercus alba) and European red oak (Quercus robur). They mainly included various glucose gallic and ellagic acid esters. The structures were partially determined, and they included grandinin/roburin E, castalagin/vescalagin, gallic acid, valoneic acid bilactone, monogalloyl glucose, digalloyl glucose, trigalloyl glucose, ellagic acid rhamnose, quercitrin and ellagic acid.

  4. The design of a calorimetric standard of ionising radiation absorbed dose

    International Nuclear Information System (INIS)

    Huntley, R.B.

    1981-05-01

    The design of a calorimetric working standard of ionising radiation absorbed dose is discussed. A brief history of the appropriate quantities and units of measurement is given. Detailed design considerations follow a summary of the relevant literature. The methods to be used to relate results to national standards of measurement are indicated, including the need for various correction factors. A status report is given on the construction and testing program

  5. A preliminary inter-centre comparison study for photon, thermal neutron and epithermal neutron responses of two pairs of ionisation chambers used for BNCT

    International Nuclear Information System (INIS)

    Roca, Antoaneta; Liu, Yuan-Hao; Wojnecki, Cecile; Green, Stuart; Nievaart, Sander; Ghani, Zamir; Moss, Ray

    2009-01-01

    The dual ionisation chamber technique is the recommended method for mixed field dosimetry of epithermal neutron beams. This paper presents initial data from an ongoing inter-comparison study involving two identical pairs of ionisation chambers used at the BNCT facilities of Petten, NL and of University of Birmingham, UK. The goal of this study is to evaluate the photon, thermal neutron and epithermal neutron responses of both pairs of TE(TE) (Exradin T2 type) and Mg(Ar) (Exradin M2 type) ionisation chambers in similar experimental conditions. At this stage, the work has been completed for the M2 type chambers and is intended to be completed for the T2 type chambers in the near future.

  6. 76 FR 40717 - Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental...

    Science.gov (United States)

    2011-07-11

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PF11-4-000] Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental Assessment for the Planned Northeast Supply Link Project, Request for Comments on Environmental Issues, and Notice of Public Scoping Meetings The staff of the Federal Energy...

  7. Non-targeted effects of ionising radiation. Proceedings of the RISC-RAD specialised training course

    International Nuclear Information System (INIS)

    Belyakov, O.V.

    2008-12-01

    The training course 'Non-targeted effects of ionising radiation' took place at the STUK, Radiation and Nuclear Safety Authority, Helsinki, Finland 14-16 February 2005. Proceeding of this course is collected in this volume. The idea of the course was to convene a number of scientists leading in the area of non-targeted effects of ionising radiation with the aim to outline their visions for the role of these effects and outline the future directions of radiation research on the basis of their expertise. The course was supported by the RISC-RAD IP FI6R-CT-2003-508842, Euratom specific programme for research and training on nuclear energy, 6th FP of the EC. The main objectives of the training course were: (1) to clarify the mechanisms of non-targeted effects, in particular, bystander effects, genomic instability and adaptive response; (2) to look if and how non-targeted effects modulate the cancer risk in the low dose region, and whether they relate to protective or harmful functions; (3) to clarify if ionising radiation can cause non-cancer diseases or beneficial effects at low and intermediate doses; (4) address the issue of individual susceptibility and other factors modifying non-targeted responses; (5) attempt to assess the relevance of non-targeted effects for radiation protection and to set the scientific basis for a modern, more realistic, radiation safety system; (6) and finally to contribute to the conceptualisation of a new paradigm in radiation biology that would cover both the classical direct (DNA-targeted) and non-targeted (indirect) effects

  8. On magnetospheric electron impact ionisation and dynamics in Titan's ram-side and polar ionosphere – a Cassini case study

    Directory of Open Access Journals (Sweden)

    G. R. Lewis

    2007-11-01

    Full Text Available We present data from the sixth Cassini flyby of Titan (T5, showing that the magnetosphere of Saturn strongly interacts with the moon's ionosphere and exo-ionosphere. A simple electron ionisation model provides a reasonable agreement with the altitude structure of the ionosphere. Furthermore, we suggest that the dense and cold exo-ionosphere (from the exobase at 1430 km and outward to several Titan radii from the surface can be explained by magnetospheric forcing and other transport processes whereas exospheric ionisation by impacting low energy electrons seems to play a minor role.

  9. Cosmic rays, gas and dust in nearby anticentre clouds. I. CO-to-H2 conversion factors and dust opacities

    Science.gov (United States)

    Remy, Q.; Grenier, I. A.; Marshall, D. J.; Casandjian, J. M.

    2017-05-01

    Aims: We aim to explore the capabilities of dust emission and γ rays for probing the properties of the interstellar medium in the nearby anti-centre region, using γ-ray observations with the Fermi Large Area Telescope (LAT), and the thermal dust optical depth inferred from Planck and IRAS observations. We also aim to study massive star-forming clouds including the well known Taurus, Auriga, Perseus, and California molecular clouds, as well as a more diffuse structure which we refer to as Cetus. In particular, we aim at quantifying potential variations in cosmic-ray density and dust properties per gas nucleon across the different gas phases and different clouds, and at measuring the CO-to-H2 conversion factor, XCO, in different environments. Methods: We have separated six nearby anti-centre clouds that are coherent in velocities and distances, from the Galactic-disc background in H I 21-cm and 12CO 2.6-mm line emission. We have jointly modelled the γ-ray intensity recorded between 0.4 and 100 GeV, and the dust optical depth τ353 at 353 GHz as a combination of H I-bright, CO-bright, and ionised gas components. The complementary information from dust emission and γ rays was used to reveal the gas not seen, or poorly traced, by H I, free-free, and 12CO emissions, namely (I) the opaque H iand diffuse H2 present in the Dark Neutral Medium at the atomic-molecular transition, and (II) the dense H2 to be added where 12CO lines saturate. Results: The measured interstellar γ-ray spectra support a uniform penetration of the cosmic rays with energies above a few GeV through the clouds, from the atomic envelopes to the 12CO-bright cores, and with a small ± 9% cloud-to-cloud dispersion in particle flux. We detect the ionised gas from the H iiregion NGC 1499 in the dust and γ-ray emissions and measure its mean electron density and temperature. We find a gradual increase in grain opacity as the gas (atomic or molecular) becomes more dense. The increase reaches a factor of

  10. Thermal analysis of LOFT waste gas processing system nitrogen supply for process line purge and blower seal

    International Nuclear Information System (INIS)

    Tatar, G.A.

    1979-01-01

    The LOFT Waste Gas Processing System uses gaseous nitrogen (GN 2 ) to purge the main process line and to supply pressure on the blower labyrinth seal. The purpose of this analysis was to determine the temperature of the GN 2 at the blower seals and the main process line. Since these temperatures were below 32 0 F the heat rate necessary to raise these temperatures was calculated. This report shows that the GN 2 temperatures at the points mentioned above were below 10 0 F. A heat rate into the GN 2 of 389 Watts added at the point where the supply line enters the vault would raise the GN 2 temperature above 32 0 F

  11. A statistical study of H i gas in nearby narrow-line AGN-hosting galaxies

    International Nuclear Information System (INIS)

    Zhu, Yi-Nan; Wu, Hong

    2015-01-01

    As a quenching mechanism, active galactic nucleus (AGN) feedback could suppress on going star formation in host galaxies. On the basis of a sample of galaxies selected from the Arecibo Legacy Fast ALFA (ALFALFA) H i survey, the dependence of the H i mass (M H i ), stellar mass (M * ), and H i-to-stellar mass ratio (M H i /M * ) on various tracers of AGN activity are presented and analyzed in this paper. Almost all the AGN hostings in this sample are gas-rich galaxies, and there is not any evidence to indicate that the AGN activity could increase or decrease either M H i or M H i /M * . The position of the cold neutral gas cannot be fixed accurately based only on available H i data, due to the large beam size of ALFALFA survey. In addition, even though AGN hostings are more easily detected by an H i survey compared with absorption line galaxies, these two types of galaxies show similar star formation history. If an AGN hosting would ultimately evolve into an old red galaxy with low cold gas, then when and how the gas has been exhausted must be solved by future hypotheses and observations.

  12. A statistical study of H i gas in nearby narrow-line AGN-hosting galaxies

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Yi-Nan; Wu, Hong, E-mail: zyn@bao.ac.cn, E-mail: hwu@bao.ac.cn [Key Laboratory of Optical Astronomy, National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100012 (China)

    2015-01-01

    As a quenching mechanism, active galactic nucleus (AGN) feedback could suppress on going star formation in host galaxies. On the basis of a sample of galaxies selected from the Arecibo Legacy Fast ALFA (ALFALFA) H i survey, the dependence of the H i mass (M{sub H} {sub i}), stellar mass (M{sub *}), and H i-to-stellar mass ratio (M{sub H} {sub i}/M{sub *}) on various tracers of AGN activity are presented and analyzed in this paper. Almost all the AGN hostings in this sample are gas-rich galaxies, and there is not any evidence to indicate that the AGN activity could increase or decrease either M{sub H} {sub i} or M{sub H} {sub i}/M{sub *}. The position of the cold neutral gas cannot be fixed accurately based only on available H i data, due to the large beam size of ALFALFA survey. In addition, even though AGN hostings are more easily detected by an H i survey compared with absorption line galaxies, these two types of galaxies show similar star formation history. If an AGN hosting would ultimately evolve into an old red galaxy with low cold gas, then when and how the gas has been exhausted must be solved by future hypotheses and observations.

  13. Exotic highly ionising particles at the LHC

    CERN Document Server

    De Roeck, A; Mermod, P; Milstead, D; Sloan, T

    2012-01-01

    The experiments at the Large Hadron Collider (LHC) are able to discover or set limits on the production of exotic particles with TeV-scale masses possessing values of electric and/or magnetic charge such that they appear as highly ionising particles (HIPs). In this paper the sensitivity of the LHC experiments to HIP production is discussed in detail. It is shown that a number of different detection methods are required to investigate as fully as possible the charge-mass range. These include direct detection as the HIPs pass through detectors and, in the case of magnetically charged objects, the so-called induction method with which monopoles which stop in accelerator and detector material could be observed. The benefit of using complementary approaches to HIP detection is discussed.

  14. Thermal ionisation mass spectrometry (TIMS): what, how and why?

    International Nuclear Information System (INIS)

    Aggarwal, S.K.

    2002-01-01

    Thermal ionisation mass spectrometry (TIMS) is one of the oldest mass spectrometric techniques, which has been used for determining the isotopic composition and concentration of different elements using isotope dilution. In spite of the introduction of many other inorganic mass spectrometric techniques like spark source mass spectrometry (SSMS), glow discharge mass spectrometry (GDMS), inductively coupled plasma-mass spectrometry (ICP-MS), secondary ion mass spectrometry (SIMS), the TIMS technique plays the role of a definitive analytical methodology and still occupies a unique position in terms of its capabilities with respect to precision and accuracy as well as sensitivity

  15. The Radman Guide to the Ionising Radiations Regulations 1985

    International Nuclear Information System (INIS)

    Hughes, D.

    1986-01-01

    The guidance given in the handbook is of general nature for the assistance of senior managers and administrators (rather than scientific or technical staff), involved in or responsible for work with ionising radiations. The subject is dealt with under the following headings: 1) Digest of the Regulations. 2) Application of Regulations (division of responsibility between employer, employee, supervisors, medical personnel etc., role of the Health and Safety Executive.) 3) Designation of work areas and persons 4) Radiation Protection Supervisors and Local Rules 5) Hazard assessments and contingency plans 6) Notifications and Record Keeping 7) Routines in source control. (UK)

  16. A NLTE line formation for neutral and singly-ionised calcium in model atmospheres of B-F stars

    Science.gov (United States)

    Sitnova, T. M.; Mashonkina, L. I.; Ryabchikova, T. A.

    2018-03-01

    We present non-local thermodynamic equilibrium (NLTE) line formation calculations for Ca I and Ca II in B-F stars. The sign and the magnitude of NLTE abundance corrections depend on line and stellar parameters. We determine calcium abundances for nine stars with reliable stellar parameters. For all stars, where the lines of both species could be measured, the NLTE abundances are found to be consistent within the error bars. We obtain consistent NLTE abundances from Ca II lines in the visible and near infra-red (IR, 8912-27, 9890 Å) spectrum range, in contrast with LTE, where the discrepancy between the two groups of lines ranges from -0.5 dex to 0.6 dex for different stars. Our NLTE method reproduces the Ca II 8912-27, 9890 Å lines observed in emission in the late B-type star HD 160762 with the classical plane-parallel and LTE model atmosphere. NLTE abundance corrections for lines of Ca I and Ca II were calculated in a grid of model atmospheres with 7000 K ≤ Teff ≤ 13000 K, 3.2 ≤ log g ≤ 5.0, -0.5 ≤ [Fe/H] ≤0.5, ξt= 2.0 km s-1. Our NLTE results can be applied for calcium NLTE abundance determination from Gaia spectra, given that accurate continuum normalisation and proper treatment of the hydrogen Paschen lines are provided. The NLTE method can be useful to refine calcium underabundances in Am stars and to provide accurate observational constraints on the models of diffusion.

  17. The L1-shell ionisation of atoms by relativistic particles

    International Nuclear Information System (INIS)

    Moiseiwitsch, B.L.; Norrington, P.H.

    1979-01-01

    An expression for the L 1 -shell ionisation cross sections of atoms by high-energy particles has been derived using the relativistic plane-wave Born approximation. The incident and scattered particles are described by Dirac plane waves while Darwin hydrogenic wavefunctions are used for the atomic electrons. A comparison is made with experimental total cross sections for incident electrons in the energy range 1-2 MeV. The agreement is a considerable improvement on that obtained using the non-relativistic planewave Born approximation. (author)

  18. Transcription-based model for the induction of chromosomal exchange events by ionising radiation

    International Nuclear Information System (INIS)

    Radford, I.A.

    2003-01-01

    The mechanistic basis for chromosomal aberration formation, following exposure of mammalian cells to ionising radiation, has long been debated. Although chromosomal aberrations are probably initiated by DNA double-strand breaks (DSB), little is understood about the mechanisms that generate and modulate DNA rearrangement. Based on results from our laboratory and data from the literature, a novel model of chromosomal aberration formation has been suggested (Radford 2002). The basic postulates of this model are that: (1) DSB, primarily those involving multiple individual damage sites (i.e. complex DSB), are the critical initiating lesion; (2) only those DSB occurring in transcription units that are associated with transcription 'factories' (complexes containing multiple transcription units) induce chromosomal exchange events; (3) such DSB are brought into contact with a DNA topoisomerase I molecule through RNA polymerase II catalysed transcription and give rise to trapped DNA-topo I cleavage complexes; and (4) trapped complexes interact with another topo I molecule on a temporarily inactive transcription unit at the same transcription factory leading to DNA cleavage and subsequent strand exchange between the cleavage complexes. We have developed a method using inverse PCR that allows the detection and sequencing of putative ionising radiation-induced DNA rearrangements involving different regions of the human genome (Forrester and Radford 1998). The sequences detected by inverse PCR can provide a test of the prediction of the transcription-based model that ionising radiation-induced DNA rearrangements occur between sequences in active transcription units. Accordingly, reverse transcriptase PCR was used to determine if sequences involved in rearrangements were transcribed in the test cells. Consistent with the transcription-based model, nearly all of the sequences examined gave a positive result to reverse transcriptase PCR (Forrester and Radford unpublished)

  19. Study of turbulent and shock heated IGM gas with emission line spectroscopy in the Taffy galaxies

    Science.gov (United States)

    Joshi, Bhavin; Appleton, Phil; Blanc, Guillermo; Guillard, Pierre; Freeland, Emily; Peterson, Bradley; Alatalo, Katherine

    2018-01-01

    We present our results from optical IFU observations of the Taffy system (UGC 12914/15); named so because of the radio emission that stretches between the two galaxies. The Taffy galaxies are a major merger pair of galaxies where two gas-rich spiral galaxies have collided face on and passed through each other. The pair presents an unusually low IR luminosity (L_FIR ~ 4.5 x 10^{10} L_solar) and SFR (~ 0.23 M_solar / yr) for a typical post merger system. It was also found from Spitzer and Chandra observations that the Taffy "bridge" between the galaxies contains large amounts of warm molecular Hydrogen, >4.5 x 10^8 M_solar at 150-175K, and also shows soft X-ray emission. These results hinted at shock heating as a likely mechanism for heating the large amounts of gas in the Taffy bridge and keeping it at these temperatures, after other sources of heating are ruled out. The data we present in this paper are from the VIRUS-P instrument (now called GCMS) on the Harlan J. Smith 2.7m telescope at McDonald Observatory. We detect ionized gas all throughout the Taffy galaxies and in the bridge between them. Interestingly, the ionized gas shows emission line profiles with two velocity components almost all throughout the system. We also show evidence, through line diagnostic (BPT) diagrams, that the velocity component with lower velocity is likely excited by star formation whereas the velocity component with higher velocity is likely excited by shocks. We also find evidence for post-starburst populations in parts of the Taffy system.

  20. Gas Generation during Sodium Permanganate Addition to HB-Line Phase II Filtrate Tank

    International Nuclear Information System (INIS)

    Hill, B.C.

    2002-01-01

    HB-Line Phase II process requires the addition of sodium permanganate followed by a sodium nitrite addition to prevent the precipitation of plutonium solids in a non-geometrically safe vessel. Previous experimental work has shown this method effective. Current concerns are related to the gas generated by the reaction. Potential difficulties include tank over-pressurization and tank overflow due to foaming or eructation. It is also necessary to verify that the quantity of permanganate specified by the facility is sufficient to reach the desired endpoint in a single addition

  1. Commercial potential of natural gas storage in lined rock caverns (LRC); FINAL

    International Nuclear Information System (INIS)

    NONE

    1999-01-01

    The geologic conditions in many regions of the United States will not permit the development of economical high-deliverability gas storage in salt caverns. These regions include the entire Eastern Seaboard; several northern states, notably Minnesota and Wisconsin; many of the Rocky Mountain States; and most of the Pacific Northwest. In late 1997, the United States Department of Energy (USDOE) Federal Energy Technology Center engaged Sofregaz US to investigate the commercialization potential of natural gas storage in Lined Rock Caverns (LRC). Sofregaz US teamed with Gaz de France and Sydkraft, who had formed a consortium, called LRC, to perform the study for the USDOE. Underground storage of natural gas is generally achieved in depleted oil and gas fields, aquifers, and solution-mined salt caverns. These storage technologies require specific geologic conditions. Unlined rock caverns have been used for decades to store hydrocarbons - mostly liquids such as crude oil, butane, and propane. The maximum operating pressure in unlined rock caverns is limited, since the host rock is never entirely impervious. The LRC technology allows a significant increase in the maximum operating pressure over the unlined storage cavern concept, since the gas in storage is completely contained with an impervious liner. The LRC technology has been under development in Sweden by Sydkraft since 1987. The development process has included extensive technical studies, laboratory testing, field tests, and most recently includes a storage facility being constructed in southern Sweden (Skallen). The LRC development effort has shown that the concept is technically and economically viable. The Skallen storage facility will have a rock cover of 115 meters (375 feet), a storage volume of 40,000 cubic meters (250,000 petroleum barrels), and a maximum operating pressure of 20 MPa (2,900 psi). There is a potential for commercialization of the LRC technology in the United States. Two regions were studied

  2. Literature Review: Theory and Application of In-Line Inspection Technologies for Oil and Gas Pipeline Girth Weld Defection

    Science.gov (United States)

    Feng, Qingshan; Li, Rui; Nie, Baohua; Liu, Shucong; Zhao, Lianyu; Zhang, Hong

    2016-01-01

    Girth weld cracking is one of the main failure modes in oil and gas pipelines; girth weld cracking inspection has great economic and social significance for the intrinsic safety of pipelines. This paper introduces the typical girth weld defects of oil and gas pipelines and the common nondestructive testing methods, and systematically generalizes the progress in the studies on technical principles, signal analysis, defect sizing method and inspection reliability, etc., of magnetic flux leakage (MFL) inspection, liquid ultrasonic inspection, electromagnetic acoustic transducer (EMAT) inspection and remote field eddy current (RFDC) inspection for oil and gas pipeline girth weld defects. Additionally, it introduces the new technologies for composite ultrasonic, laser ultrasonic, and magnetostriction inspection, and provides reference for development and application of oil and gas pipeline girth weld defect in-line inspection technology. PMID:28036016

  3. Can the waiting-point nucleus 78Ni be studied at an on-line mass-separator?

    Science.gov (United States)

    Wöhr, A.; Andreyev, A.; Bijnens, N.; Breitenbach, J.; Franchoo, S.; Huyse, M.; Kudryavtsev, Y. A.; Piechaczek, A.; Raabe, R. R.; Reusen, I.; Vermeeren, L.; Van Duppen, P.

    1997-02-01

    Short-lived nickel isotopes have been studied using a chemically selective Ion Guide Laser Ion Source (IGLIS) based on resonance ionisation of atoms at the Leuven Isotope Separator On-Line (LISOL) separator. The decay properties of different Ni isotopes have been studied using β-γ-coincidences. Experimental production rates of proton induced fission of 238U are obtained for 69,71Ni. These numbers are in a strong disagreement with Silberg-Tsao calculations.

  4. Circumnuclear Multi-phase Gas in the Circinus Galaxy. I. Non-LTE Calculations of CO Lines

    Science.gov (United States)

    Wada, Keiichi; Fukushige, Ryosuke; Izumi, Takuma; Tomisaka, Kohji

    2018-01-01

    In this study, we investigate the line emissions from cold molecular gas based on our previous “radiation-driven fountain model,” which reliably explains the spectral energy distribution of the nearest type 2 Seyfert galaxy, the Circinus galaxy. Using a snapshot of the best-fit radiation-hydrodynamic model for the central r≤slant 16 pc, in which non-equilibrium X-ray-dominated region chemistry is solved, we conduct post-processed non-local thermodynamic equilibrium radiation transfer simulations for the CO lines. We obtain a spectral line energy distribution with a peak around J≃ 6, and its distribution suggests that the lines are not thermalized. However, for a given line of sight, the optical depth distribution is highly non-uniform between {τ }ν \\ll 1 and {τ }ν \\gg 1. The CO-to-H2 conversion factor ({X}{CO}), which can be directly obtained from the results and is not a constant, depends strongly on the integrated intensity and differs from the fiducial value for local objects. {X}{CO} exhibits a large dispersion of more than one order of magnitude, reflecting the non-uniform internal structure of a “torus.” In addition, we found that the physical conditions differ between grid cells on a scale of a few parsecs along the observed lines of sight; therefore, a specific observed line ratio does not necessarily represent a single physical state of the interstellar medium.

  5. First Glossary of Modern Physics and Ionising Radiation Protection in Croatian

    International Nuclear Information System (INIS)

    Nodilo, M.; Petkovic, T.

    2011-01-01

    Motivation and encouragement for the Glossary were given as the research theme for the joint seminar between the Faculty of Electrical Engineering and Computing and Rudjer Boskovic Institute, within a postgraduate course subject ''Detectors and electronic instrumentation for particle physics''. A basic motivation is due to a lack of specialized literature in Croatian language in the field of protection of ionising radiation as well as the incompleteness of Croatian terminology in the same field. That is a general problem all over the World because the most glossaries are usually connected either with nuclear power plants or with an application of ionising radiation in medicine. On the other hand, a necessity for the specialized literature for radiation protection which follows a development of modern particle physics and its detection technique is rapidly growing up. A work and development on the Glossary were faced with serious difficulties, since various translations of foreign words and acronyms have already been used by various authors in Croatian literature. Different interpretations of the same term or concept, from diverse sources, had to be very often reconciled. However, the biggest challenge was finding proper Croatian words for the foreign terms, concepts, properties, and quantities which have not yet been commonly used so far in Croatian papers or/and Croatian legislative acts. According to our knowledge this seems to be the first comprehensive Glossary, describing the field of ionising radiation protection and bringing of 300 related entries (terms and guidelines). That is, certainly, the first characteristic Thesaurus in Croatian which includes background of modern physics and chemistry, particle phenomenology and its measurement, all dedicated to the radiological protection of workers, environment and people of the World. A Glossary brings a wide spectrum of terms of broad area of chemistry, radiation protection, nuclear and particle physics. A

  6. The 2010 calibration campaign for radon gas measuring instruments at PSI

    International Nuclear Information System (INIS)

    Butterweck, G.; Schuler, Ch.; Mayer, S.

    2011-01-01

    Twenty radon measurement services or the respective analytical laboratories participated in the 2010 Radon Intercomparison Exercise performed at the Reference Laboratory for Radon Gas Activity Concentration Measurements at the Paul Scherrer Institute (PSI) from August 27 th to August 31 st , 2010 on behalf of the Swiss Federal Office of Public Health (FOPH). Twelve of these laboratories were approved by the FOPH and their participation in the intercomparison exercise was a requirement to warrant quality of measurement. Radon gas dosemeters (track-etch, electronic and electret) and instruments (ionisation chambers) were exposed in the PSI Radon Chamber in a reference atmosphere with an average radon gas concentration of 595 Bq m -3 leading to a radon gas exposure of 57 kBq h m -3 . The exposure of 57 kBq h m -3 was close to the lower value of the measuring range defined in the Radon Measurement Ordinance ('Radon-Messmittelverordnung'). (authors)

  7. Using the Pairs of Lines Broadened by Collisions with Neutral and Charged Particles for Gas Temperature Determination of Argon Non-Thermal Plasmas at Atmospheric Pressure

    Directory of Open Access Journals (Sweden)

    Cristina Yubero

    2017-10-01

    Full Text Available The spectroscopic method for gas temperature determination in argon non-thermal plasmas sustained at atmospheric pressure proposed recently by Spectrochimica Acta Part B 129 14 (2017—based on collisional broadening measurements of selected pairs of argon atomic lines, has been applied to other pairs of argon atomic lines, and the discrepancies found in some of these results have been analyzed. For validation purposes, the values of the gas temperature obtained using the different pairs of lines have been compared with the rotational temperatures derived from the OH ro-vibrational bands, using the Boltzmann-plot technique.

  8. Multi-wavelength study of the Seyfert 1 galaxy NGC 3783 with XMM-Newton

    CERN Document Server

    Blustin, A J; Behar, E; Kaastra, J S; Kahn, S M; Page, M J; Sako, M; Steenbrugge, K C

    2002-01-01

    We present the analysis of multi-wavelength XMM-Newton data from the Seyfert galaxy NGC 3783, including UV imaging, X-ray and UV lightcurves, the 0.2-10 keV X-ray continuum, the iron K-alpha emission line, and high-resolution spectroscopy and modelling of the soft X-ray warm absorber. The 0.2-10 keV spectral continuum can be well reproduced by a power-law at higher energies; we detect a prominent Fe K-alpha emission line, with both broad and narrow components, and a weaker emission line at 6.9 keV which is probably a combination of Fe K-beta and Fe XXVI. We interpret the significant deficit of counts in the soft X-ray region as being due to absorption by ionised gas in the line of sight. This is demonstrated by the large number of narrow absorption lines in the RGS spectrum from iron, oxygen, nitrogen, carbon, neon, argon, magnesium, silicon and sulphur. The wide range of iron states present in the spectrum enables us to deduce the ionisation structure of the absorbing medium. We find that our spectrum contai...

  9. Large area gridded ionisation chamber and electrostatic precipitator. Application to low-level alphaspectrometry of environmental air samples

    International Nuclear Information System (INIS)

    Hoetzl, H.; Winkler, R.

    1978-01-01

    A high-resolution, parallel plate Frisch grid ionisation chamber with an efficient area of 300 cm 2 and a large area electrostatic precipitator were developed and applied to direct alpha-particle spectrometry of air dust. The aerosols were deposited on circular tin-plate dishes of 300 cm 2 by the electrostatic precipitator, which was constructed for continuous operation at an air flow rate of 2 m 3 /h. Collection efficiency is found to be 0.78 for the natural Rn- and Tn-daughter products. Using an argon-methane mixture (P-10 gas) at atmospheric pressure, the resolution of the detector system is 22 keV fwhm at 5.15 MeV. The integral background is typically 15.7 counts/h between 4 and 6 MeV. After sampling for one week and decay of short-lived natural activity, the sensitivity of the procedure for long-lived alpha-emitters is about 0.1 fCi/m 3 based on 3s of background as detection limit and 1000 min counting time. (Auth.)

  10. Irradiation specifically sensitises solid tumour cell lines to TRAIL mediated apoptosis

    International Nuclear Information System (INIS)

    Marini, Patrizia; Schmid, Angelika; Jendrossek, Verena; Faltin, Heidrun; Daniel, Peter T; Budach, Wilfried; Belka, Claus

    2005-01-01

    TRAIL (tumor necrosis factor related apoptosis inducing ligand) is an apoptosis inducing ligand with high specificity for malignant cell systems. Combined treatment modalities using TRAIL and cytotoxic drugs revealed highly additive effects in different tumour cell lines. Little is known about the efficacy and underlying mechanistic effects of a combined therapy using TRAIL and ionising radiation in solid tumour cell systems. Additionally, little is known about the effect of TRAIL combined with radiation on normal tissues. Tumour cell systems derived from breast- (MDA MB231), lung- (NCI H460) colorectal- (Colo 205, HCT-15) and head and neck cancer (FaDu, SCC-4) were treated with a combination of TRAIL and irradiation using two different time schedules. Normal tissue cultures from breast, prostate, renal and bronchial epithelia, small muscle cells, endothelial cells, hepatocytes and fibroblasts were tested accordingly. Apoptosis was determined by fluorescence microscopy and western blot determination of PARP processing. Upregulation of death receptors was quantified by flow cytometry. The combined treatment of TRAIL with irradiation strongly increased apoptosis induction in all treated tumour cell lines compared to treatment with TRAIL or irradiation alone. The synergistic effect was most prominent after sequential application of TRAIL after irradiation. Upregulation of TRAIL receptor DR5 after irradiation was observed in four of six tumour cell lines but did not correlate to tumour cell sensitisation to TRAIL. TRAIL did not show toxicity in normal tissue cell systems. In addition, pre-irradiation did not sensitise all nine tested human normal tissue cell cultures to TRAIL. Based on the in vitro data, TRAIL represents a very promising candidate for combination with radiotherapy. Sequential application of ionising radiation followed by TRAIL is associated with an synergistic induction of cell death in a large panel of solid tumour cell lines. However, TRAIL receptor

  11. Nailfold Capillaroscopic Monitoring as Preventive Medicine in Subjects Exposed to Ionising Radiation

    International Nuclear Information System (INIS)

    Pennarola, R.; Perdereau, B.; Trenta, G.; Cosset, J. M.

    2004-01-01

    Capillaroscopy consists of in vivo observation of microvessels using special microscopes with a short focal length. Normally, when looking at the nail fold, where capillaroscopy is commonly used, the capillaries ares arranged like hairpins, lined up in parallel or obliquely to the field of vision in three or four layers above the subpapillary venous network, approximately 20 loops per mm''2. Ionising radiation can badly damage the skin and underlying tissues. The capillary network is among the first structures to show an effect. Moderate doses of radiation cause damage endothelial cells with hypertrophy or hyperplasia of endothelial cells, which can block capillaries while having little effect on larger vessels. Occlusion of capillaries impedes blood flow no only in nearby tissue but also in areas farther away. Capillaroscopic examination of the nail fold is irreplaceable in the field of radioprotection especially in cases of exposure of the hands. Nailfold capillaroscopic monitoring lets us observe the degree to which qualitative and quantitative alterations of the capillaries are a function of the evolution of the lesion. Therefore, for biological monitoring of subjects exposed to radiation the authors propose to use this microvascular quantitative analysis of the nailfold region. Experience, matured over many years by our team, highlights the relation between the sum of repeated exposure and the importance of tissue alterations evidenced by microcirculation. (Author) 9 refs

  12. Real-time analysis of aromatics in combustion engine exhaust by resonance-enhanced multiphoton ionisation time-of-flight mass spectrometry (REMPI-TOF-MS): a robust tool for chassis dynamometer testing

    Energy Technology Data Exchange (ETDEWEB)

    Adam, T.W. [European Commission Joint Research Centre, Institute for Environment and Sustainability, Transport and Air Quality Unit, Ispra, VA (Italy); Clairotte, M.; Manfredi, U.; Carriero, M.; Martini, G.; Krasenbrink, A.; Astorga, C. [European Commission Joint Research Centre, Institute for Environment and Sustainability, Transport and Air Quality Unit, Ispra, VA (Italy); European Commission Joint Research Centre, Institute for Energy and Transport, Sustainable Transport Unit, Ispra, Varese (Italy); Streibel, T.; Pommeres, A.; Sklorz, M. [University of Rostock, Analytical Chemistry/Joint Mass Spectrometry Centre, Institute of Chemistry, Rostock (Germany); Elsasser, M.; Zimmermann, R. [Cooperation Group Complex Molecular Systems (CMA)/Joint Mass Spectrometry Centre (JMSC), Neuherberg (Germany); University of Rostock, Analytical Chemistry/Joint Mass Spectrometry Centre, Institute of Chemistry, Rostock (Germany)

    2012-07-15

    Resonance-enhanced multiphoton ionisation time-of-flight mass spectrometry (REMPI-TOF-MS) is a robust method for real-time analysis of monocyclic and polycyclic aromatic hydrocarbons in complex emissions. A mobile system has been developed which enables direct analysis on site. In this paper, we utilize a multicomponent calibration scheme based on the analytes' photo-ionisation cross-sections relative to a calibrated species. This allows semi-quantification of a great number of components by only calibrating one compound of choice, here toluene. The cross-sections were determined by injecting nebulised solutions of aromatic compounds into the TOF-MS ion source with the help of a HPLC pump. Then, REMPI-TOF-MS was implemented at various chassis dynamometers and test cells and the exhaust of the following vehicles and engines investigated: a compression ignition light-duty (LD) passenger car, a compression ignition LD van, two spark ignition LD passenger cars, 2 two-stroke mopeds, and a two-stroke engine of a string gas trimmer. The quantitative time profiles of benzene are shown. The results indicate that two-stroke engines are a significant source for toxic and cancerogenic compounds. Air pollution and health effects caused by gardening equipment might still be underestimated. (orig.)

  13. 77 FR 32626 - Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental Impact...

    Science.gov (United States)

    2012-06-01

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PF09-8-000] Transcontinental Gas Pipe Line Company, LLC; Notice of Intent To Prepare an Environmental Impact Statement for the Planned Rockaway Delivery Lateral Project, Request for Comments on Environmental Issues, and Notice of Public Scoping Meetings The staff of the Federa...

  14. Adaptive response to ionising radiation induced by cadmium in zebrafish embryos

    International Nuclear Information System (INIS)

    Choi, V W Y; Ng, C Y P; Kong, M K Y; Yu, K N; Cheng, S H

    2013-01-01

    An adaptive response is a biological response where the exposure of cells or animals to a low priming exposure induces mechanisms that protect the cells or animals against the detrimental effects of a subsequent larger challenging exposure. In realistic environmental situations, living organisms can be exposed to a mixture of stressors, and the resultant effects due to such exposures are referred to as multiple stressor effects. In the present work we demonstrated, via quantification of apoptosis in the embryos, that embryos of the zebrafish (Danio rerio) subjected to a priming exposure provided by one environmental stressor (cadmium in micromolar concentrations) could undergo an adaptive response against a subsequent challenging exposure provided by another environmental stressor (alpha particles). We concluded that zebrafish embryos treated with 1 to 10 μM Cd at 5 h postfertilisation (hpf) for both 1 and 5 h could undergo an adaptive response against subsequent ∼4.4 mGy alpha-particle irradiation at 10 hpf, which could be interpreted as an antagonistic multiple stressor effect between Cd and ionising radiation. The zebrafish has become a popular vertebrate model for studying the in vivo response to ionising radiation. As such, our results suggested that multiple stressor effects should be carefully considered for human radiation risk assessment since the risk may be perturbed by another environmental stressor such as a heavy metal. (paper)

  15. Gas detection system

    International Nuclear Information System (INIS)

    Allan, C.J.; Bayly, J.G.

    1975-01-01

    The gas detection system provides for the effective detection of gas leaks over a large area. It includes a laser which has a laser line corresponding to an absorption line of the gas to be detected. A He-Xe laser scans a number of retroreflectors which are strategically located around a D 2 O plant to detect H 2 S leaks. The reflected beam is focused by a telescope, filtered, and passed into an infrared detector. The laser may be made to emit two frequencies, one of which corresponds with an H 2 S absorption line; or it may be modulated on and off the H 2 S absorption line. The relative amplitude of the absorbed light will be a measure of the H 2 S present

  16. Ionising radiations - an ecological problem of indoor architectural environment

    International Nuclear Information System (INIS)

    Djukanovic, M.

    1995-01-01

    Architectural buildings are assessed not only for their esthetic characteristics but human settlements are considered now, as ecosystems and homes and flats as habitats (bio tops). Because of that healthy environment and influences of nonpolluting factors are of a great importance. The use of appropriate building materials harmless to health, contrary to the use of those that emit radon with its ionising effects and consequent health hazards, is of a great importance, too. The purpose of this paper is to emphasize the importance of investigation of building materials before their use, as well as the importance of quality control of soil where the construction is planned. (author)

  17. On analytical fits for electron impact ionisation cross sections

    International Nuclear Information System (INIS)

    Godunov, A.L.; Ivanov, P.B.

    1999-01-01

    The problem of providing accurate recommended analytical fits for electron impact ionisation cross sections is discussed, and a number of approaches are considered on the sample case of neon and its ions. The previously known fits are being reassessed using complete experimental and theoretical data, with the preference for experiment, to avoid systematic shifts introduced by the present calculation methods. The feasibility of the standard BELI formula is investigated in detail, and a number of other analytical expressions is suggested, approximating single-ionization cross sections in the whole range of energies. The factors influencing the accuracy of the fits and the physical meaning of the parameters obtained are discussed. (orig.)

  18. Development of a low-energy radioactive ion beam facility for the MARA separator

    Energy Technology Data Exchange (ETDEWEB)

    Papadakis, Philippos, E-mail: philippos.papadakis@jyu.fi; Moore, Iain; Pohjalainen, Ilkka; Sarén, Jan; Uusitalo, Juha [University of Jyväskylä, Department of Physics (Finland)

    2016-12-15

    A low-energy radioactive ion beam facility for the production and study of nuclei produced close to the proton drip line is under development at the Accelerator Laboratory of the University of Jyväskylä, Finland. The facility will take advantage of the mass selectivity of the recently commissioned MARA vacuum-mode mass separator. The ions selected by MARA will be stopped and thermalised in a small-volume gas cell prior to extraction and further mass separation. The gas cell design allows for resonance laser ionisation/spectroscopy both in-gas-cell and in-gas-jet. The facility will include experimental setups allowing ion counting, mass measurement and decay spectroscopy.

  19. Determination of Organic Pollutants in Small Samples of Groundwaters by Liquid-Liquid Extraction and Capillary Gas Chromatography

    DEFF Research Database (Denmark)

    Harrison, I.; Leader, R.U.; Higgo, J.J.W.

    1994-01-01

    A method is presented for the determination of 22 organic compounds in polluted groundwaters. The method includes liquid-liquid extraction of the base/neutral organics from small, alkaline groundwater samples, followed by derivatisation and liquid-liquid extraction of phenolic compounds after neu...... neutralisation. The extracts were analysed by capillary gas chromatography. Dual detection by flame Ionisation and electron capture was used to reduce analysis time....

  20. Mixed metazoan and bacterial infection of the gas bladder of the lined seahorse-a case report.

    Science.gov (United States)

    Anderson, Paul A; Petty, Barbara D

    2013-03-01

    Five wild-caught Lined Seahorses Hippocampus erectus from an aquarium system presented with altered buoyancy and distended upper trunks. Radiography of one specimen revealed a reduced air volume in the gas bladder. Pneumocystocentesis revealed a brown exudate of numerous leukocytes, parasite ova, and Gram- and acid-fast-positive bacilli under wet mounts and stains. Necropsies revealed enlarged, friable kidneys and distended gas bladders containing copious purulent exudate, necrotic tissue, and adult digeneans Dictysarca virens. Bacterial isolates from exudate cultures grown on Lowenstein-Jensen medium were identified as Gordonia sp. and Mycobacterium poriferae by high-performance liquid chromatography and 16S ribosomal DNA sequencing. Histopathology demonstrated a histiocytic response in kidney and gas bladder exudate, inflammation of the gas bladder wall, and infection of the gas bladder lumen with parasite ova and acid-fast-positive and Gomori's methenamine silver-positive bacilli. Praziquantel is prescribed for digenean infections but dissolves incompletely in seawater and is toxic to this host. Eradication of intermediate host vectors is a management option. Treatment of Gordonia infection has not been addressed in nonhuman animals, and there is no known effective treatment for Mycobacterium spp. infection in fishes. This is the first case report of digenean infection of the gas bladder in a syngnathid, Gordonia sp. infection in a nonhuman animal, and M. poriferae infection in a fish.

  1. Data correlation in on-line solid-phase extraction-gas chromatography-atomic emission/mass spectrometric detection of unknown microcontaminants

    NARCIS (Netherlands)

    Hankemeier, Th.; Rozenbrand, J.; Abhadur, M.; Vreuls, J.J.; Brinkman, U.A.Th.

    1998-01-01

    A procedure is described for the (non-target) screening of hetero-atom-containing compounds in tap and waste water by correlating data obtained by gas chromatography (GC) using atomic emission (AED) and mass selective (MS) detection. Solid-phase extraction (SPE) was coupled on-line to both GC

  2. Use of ionising radiation in the teaching of physics and chemistry

    International Nuclear Information System (INIS)

    2000-01-01

    The guide lays down the safety requirements for the use of radiation in school education, as well as the principles regulating the use of radiation sources without the safety licence referred to in section 16 of the Finnish Radiation Act (592/1991). The guide covers the use of radiation sources emitting ionising radiation in elementary schools and high schools, as well as the use of radiation in the teaching of physics and chemistry in vocational training institutions and corresponding educational institutions

  3. RANDOMNUMBERS, Random Number Sequence Generated from Gas Ionisation Chamber Data

    International Nuclear Information System (INIS)

    Frigerio, N.A.; Sanathanan, L.P.; Morley, M.; Tyler, S.A.; Clark, N.A.; Wang, J.

    1989-01-01

    1 - Description of problem or function: RANDOM NUMBERS is a data collection of almost 2.7 million 31-bit random numbers generated by using a high resolution gas ionization detector chamber in conjunction with a 4096-channel multichannel analyzer to record the radioactive decay of alpha particles from a U-235 source. The signals from the decaying alpha particles were fed to the 4096-channel analyzer, and for each channel the frequency of signals registered in a 20,000-microsecond interval was recorded. The parity bits of these frequency counts, 0 for an even count and 1 for and odd count, were then assembled in sequence to form 31-bit random numbers and transcribed onto magnetic tape. This cycle was repeated to obtain the random numbers. 2 - Method of solution: The frequency distribution of counts from the device conforms to the Brockwell-Moyal distribution which takes into account the dead time of the counter. The count data were analyzed and tests for randomness on a sample indicate that the device is a highly reliable source of truly random numbers. 3 - Restrictions on the complexity of the problem: The RANDOM NUMBERS tape contains 2,669,568 31-bit numbers

  4. Numerical Calculation of Transient Thermal Characteristics in Gas-Insulated Transmission Lines

    Directory of Open Access Journals (Sweden)

    Hongtao Li

    2013-11-01

    Full Text Available For further knowledge of the thermal characteristics in gas-insulated transmission lines (GILs installed above ground, a finite-element model coupling fluid field and thermal field is established, in which the corresponding assumptions and boundary conditions are given.  Transient temperature rise processes of the GIL under the conditions of variable ambient temperature, wind velocity and solar radiation are respectively investigated. Equivalent surface convective heat transfer coefficient and heat flux boundary conditions are updated in the analysis process. Unlike the traditional finite element methods (FEM, the variability of the thermal properties with temperature is considered. The calculation results are validated by the tests results reported in the literature. The conclusion provides method and theory basis for the knowledge of transient temperature rise characteristics of GILs in open environment.

  5. Time-dependent hydrogen ionisation in 3D simulations of the solar chromosphere. Methods and first results

    NARCIS (Netherlands)

    Leenaarts, J.; Wedemeyer-Bohm, S.

    2006-01-01

    Context. The hydrogen ionisation degree deviates substantially from statistical equilibrium under the conditions of the solar chromosphere. A realistic description of this atmospheric layer thus must account for time-dependent non-equilibrium effects. Aims. Advancing the realism of numerical

  6. Lemna minor plants chronically exposed to ionising radiation: RNA-seq analysis indicates a dose rate dependent shift from acclimation to survival strategies.

    Science.gov (United States)

    Van Hoeck, Arne; Horemans, Nele; Nauts, Robin; Van Hees, May; Vandenhove, Hildegarde; Blust, Ronny

    2017-04-01

    Ecotoxicological research provides knowledge on ionising radiation-induced responses in different plant species. However, the sparse data currently available are mainly extracted from acute exposure treatments. To provide a better understanding of environmental exposure scenarios, the response to stress in plants must be followed in more natural relevant chronic conditions. We previously showed morphological and biochemical responses in Lemna minor plants continuously exposed for 7days in a dose-rate dependent manner. In this study responses on molecular (gene expression) and physiological (photosynthetic) level are evaluated in L. minor plants exposed to ionising radiation. To enable this, we examined the gene expression profiles of irradiated L. minor plants by using an RNA-seq approach. The gene expression data reveal indications that L. minor plants exposed at lower dose rates, can tolerate the exposure by triggering acclimation responses. In contrast, at the highest dose rate tested, a high number of genes related to antioxidative defense systems, DNA repair and cell cycle were differentially expressed suggesting that only high dose rates of ionising radiation drive L. minor plants into survival strategies. Notably, the photosynthetic process seems to be unaffected in L. minor plants among the tested dose rates. This study, supported by our earlier work, clearly indicates that plants shift from acclimation responses towards survival responses at increasing dose rates of ionising radiation. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Using ionising radiation against terrorism and contrabandism - dosimetric problems

    International Nuclear Information System (INIS)

    Ankerhold, U.; Hupe, O.; Buchholz, G.

    2006-01-01

    As will be explained in more detail in a talk at this conference, the personnel X-ray scanners can be divided into two groups, one using the transmitted X rays for image creation, the other one using the Compton back scatters X-rays. In the case of a backscatter scanner, a narrow, pencil -like X-ray beam is produced by a rotating chopper-wheel. The person/object is scanned in a raster scan pattern. The backscattered X-rays of all points are measured and recorded. The transmission X-ray scanner can use both fan-like and pencil like X-ray beams. The transmission detectors are installed behind the object and detect the absorption of the scanned person. Due to the very low dose values of the X-ray scanner systems in combination with a high dose rate in the direct beam for a short irradiation time, special dosemeters have to be used. In the literature and in manufacturers' specifications, the dose values given for some systems are in the range from 0.05 μSv to 5 μSv per scan with a typical irradiation time of a few milliseconds. Due to this pulse-like character of the radiation fields, the dose rate is several sieverts per hour. For the measurements of the investigated scanner, dosemeters were therefore needed having the capability to measure low doses at high dose rates and to measure in pulsed radiation fields. For the optimization of the measurements, the use of measuring devices with a direct indication is necessary. Ionisation chambers are the most suitable measuring instruments to fulfill these requirements. The difficulty for the measurements with an ionisation chamber is that the leakage charge integrated over time can reach values at the level of the expected radiation-produced charge. Additionally unpredictable variations of the leakage charge can be in the same order of magnitude as the expected signal. This challenge led to the development of a special electronics which allow the execution of time-resolved measurements. With this time resolution, it is

  8. Generation of the line radiation of argon added to DT gas in Iskra-5 experiments

    International Nuclear Information System (INIS)

    Bel'kov, S.A.; Bessarab, A.V.; Veselov, A.V.; Gaidash, V.A.; Dolgoleva, G.V.; Zhidkov, N.V.; Izgorodin, V.M.; Kirillov, G.A.; Kochemasov, G.G.; Litvin, D.N.; Martynenko, S.P.; Mitrofanov, E.I.; Murugov, V.M.; Mkhitar'yan, L.S.; Petrov, S.I.; Pinegin, A.V.; Punin, V.T.; Suslov, N.A.

    1998-01-01

    The first experiments measuring the density of a compressed deuterium and tritium mixture in microtargets of indirect irradiation (x-ray targets) were performed at the Iskra-5 facility. The density was determined according to the broadening of the lines of hydrogen- and helium-like argon added to the DT gas as a diagnostics material. A series of three experiments was performed with x-ray targets in which the central capsule filled with a DT+Ar mixture over a range of shell thicknesses. In two of the experiments, argon emission spectra were recorded and the density of the compressed gas was determined. For a microtarget approximately 280 μm in diameter with a wall approximately 7 μm thick, an analysis of the experimental results yielded an estimated density in the compressed gas of ∼1 g/cm 3 . Gas-dynamic calculations using the SNDA (spectral nonequilibrium diffusion with absorption) program show that argon emission takes place just after reaching maximum temperature, but much sooner than maximum compression. The results of a calculation for an experiment with low relative Ar concentration are in overall agreement with the experimental data. Additional investigations are needed to interpret experiments at a relatively high concentration

  9. The ATCA CABB Line Survey on Centaurus A: Properties of the Molecular Gas from the Dust Lanes to the Central Engine

    Science.gov (United States)

    Ott, Juergen; Koribalski, Baerbel; Henkel, Christian; Edwards, Philip; Norris, Ray; Meier, David; Feain, Ilana; Curran, Steve; Martin-Pintado, Jesus; Beelen, Alexandre; Aalto, Susanne; Combes, Francoise; Israel, Frank; Muller, Sebastien; Espada, Daniel; Guelin, Michel; Black, John Harry; V-Trung, Dinh; Impellizzeri, Caterina M. V.; Persson, Carina

    2011-10-01

    Centaurus A with its host NGC5128 is the most nearby radio galaxy. Its molecular spectrum exhibits three prominent features: a) gas that is located in the outer disk and dust lanes, b) absorption lines that are supposedly close to the central AGN, and c) gas in emission from the nucleus. We propose to perform an extensive line survey toward CenA using the exciting new capabilities of CABB. The broad basebands and narrow zoom bands of CABB are ideal to capture the full breath of the CenA spectral features. Our multi-band line observations will allow us to derive the exact physical conditions of each component as well as the chemistry involved. We will therefore obtain a comprehensive view of the physics imprinted on the molecular spectrum of a radio galaxy and its host, reaching from the central supermassive black hole, through the accretion region and the inner disk to the outer dust lanes.

  10. Significance of grafting in radiation curing reactions. Comparison of ionising radiation and UV systems

    International Nuclear Information System (INIS)

    Zilic, E.; Ng, L.; Viengkhou, V.; Garnett, J.L.

    1998-01-01

    Full text: Radiation curing is now an accepted commercial technology where both ionising radiation (electron beam) and ultra violet light (UV) sources are used. Grafting is essentially the copolymerisation of a monomer/oligomer to a backbone polymer whereas curing is the rapid polymerisation of a monomer/oligomer mixture onto the surface of the substrate. There is no time scale theoretically associated with grafting processes which can occur in minutes or hours whereas curing reactions are usually very rapid, occurring within a fraction of a second. An important difference between grafting and curing is the nature of the bonding occurring in each process. In grafting covalent carbon-carbon bonds are formed, whereas in curing, bonding usually involves weaker Van der Waals or London dispersion forces. The bonding properties of the systems are important in determining their use commercially. Thus the possibility that concurrent grafting during curing could occur in a system is important since if present, grafting would not only minimise delamination of the coated product but could also, in some circumstances, render difficulties recycling of the finished product especially if it were cellulosic. Hence the conditions for observing the occurrence of concurrent grafting during radiation curing are important. In the present paper, this problem has been studied by examining the effect that the components used in radiation curing exert on a typical reaction. Instead of electron beam sources, the spent fuel element facility at Lucas Heights is used to simulate such ionising radiation sources. The model system utilised is the grafting of a typical methacrylate to cellulose. This is the generic chemistry used in curing systems. The effect of typical additives from curing systems including polyfunctional monomer and oligomers in the grafting reactions have been studied. The ionising radiation results have been compared with analogous data from UV experiments. The significance

  11. Selection of the optimal combination of water vapor absorption lines for detection of temperature in combustion zones of mixing supersonic gas flows by diode laser absorption spectrometry

    International Nuclear Information System (INIS)

    Mironenko, V.R.; Kuritsyn, Yu.A.; Bolshov, M.A.; Liger, V.V.

    2017-01-01

    Determination of a gas medium temperature by diode laser absorption spectrometry (DLAS) is based on the measurement of integral intensities of the absorption lines of a test molecule (generally water vapor molecule). In case of local thermodynamic equilibrium temperature is inferred from the ratio of the integral intensities of two lines with different low energy levels. For the total gas pressure above 1 atm the absorption lines are broadened and one cannot find isolated well resolved water vapor absorption lines within relatively narrow spectral interval of fast diode laser (DL) tuning range (about 3 cm"−"1). For diagnostics of a gas object in the case of high temperature and pressure DLAS technique can be realized with two diode lasers working in different spectral regions with strong absorption lines. In such situation the criteria of the optimal line selection differs significantly from the case of narrow lines. These criteria are discussed in our work. The software for selection the optimal spectral regions using the HITRAN-2012 and HITEMP data bases is developed. The program selects spectral regions of DL tuning, minimizing the error of temperature determination δT/T, basing on the attainable experimental error of line intensity measurement δS. Two combinations of optimal spectral regions were selected – (1.392 & 1.343 μm) and (1.392 & 1.339 μm). Different algorithms of experimental data processing are discussed.

  12. An isotope view on ionising radiation as a source of sulphuric acid

    DEFF Research Database (Denmark)

    Enghoff, Martin Andreas Bødker; Bork, Nicolai Christian; Hattori, S.

    2012-01-01

    Sulphuric acid is an important factor in aerosol nucleation and growth. It has been shown that ions enhance the formation of sulphuric acid aerosols, but the exact mechanism has remained undetermined. Furthermore some studies have found a deficiency in the sulphuric acid budget, suggesting a miss...... yields of the experiments, suggests a mechanism in which ionising radiation may lead to hydrated ion clusters that serve as nanoreactors for S(IV) to S(VI) conversion....

  13. An isotopic analysis of ionising radiation as a source of sulphuric acid

    DEFF Research Database (Denmark)

    Enghoff, Martin Andreas Bødker; Bork, Nicolai Christian; Hattori, S.

    2012-01-01

    Sulphuric acid is an important factor in aerosol nucleation and growth. It has been shown that ions enhance the formation of sulphuric acid aerosols, but the exact mechanism has remained undetermined. Furthermore some studies have found a deficiency in the sulphuric acid budget, suggesting a miss...... of the experiments, suggests a mechanism in which ionising radiation may lead to hydrated ion clusters that serve as nanoreactors for S(IV) to S(VI) conversion....

  14. Characterisation of tryptic peptides of phosphorylated tyrosine hydroxylase by high-pressure liquid chromatography electrospray ionisation mass spectrometry

    International Nuclear Information System (INIS)

    Graham, Mark E.; Dickson, Phillip W.; Dunkley, Peter R.; Nagy-Felsobuki, Ellak I. von

    2005-01-01

    Tyrosine hydroxylase (TH) is involved in the biosynthesis of catecholamines and is activated by phosphorylation. Phosphorylated TH was analysed using high-pressure liquid chromatography combined with electrospray mass spectrometry (HPLC ESI-MS). Two mass scanning methods were used to detect tryptic cleavage products of TH. In the positive electrospray ionisation mode (ESI+), the peptides that contain the phosphorylation sites of TH were identified. In the alternative method, a phosphopeptide was detected in the negative electrospray ionisation mode (ESI-) using single ion monitoring in combination with a sequential ESI+ switching experiment. A raised baseline interfered with detection of hydrophilic peptides in ESI-, with the signal-to-noise ratio indicating that the method was operating near the limit of detection for a conventional electrospray source. The switching method improved the certainty of identification of phosphopeptides

  15. Resonant line transfer in a fog: using Lyman-alpha to probe tiny structures in atomic gas

    Science.gov (United States)

    Gronke, Max; Dijkstra, Mark; McCourt, Michael; Peng Oh, S.

    2017-11-01

    Motivated by observational and theoretical work that suggest very small-scale (≲ 1 pc) structure in the circumgalactic medium of galaxies and in other environments, we study Lyman-α (Lyα) radiative transfer in an extremely clumpy medium with many clouds of neutral gas along the line of sight. While previous studies have typically considered radiative transfer through sightlines intercepting ≲ 10 clumps, we explored the limit of a very large number of clumps per sightline (up to fc 1000). Our main finding is that, for covering factors greater than some critical threshold, a multiphase medium behaves similarly to a homogeneous medium in terms of the emergent Lyα spectrum. The value of this threshold depends on both the clump column density and the movement of the clumps. We estimated this threshold analytically and compare our findings to radiative transfer simulations with a range of covering factors, clump column densities, radii, and motions. Our results suggest that (I) the success in fitting observed Lyα spectra using homogeneous "shell models" (and the corresponding failure of multiphase models) hints at the presence of very small-scale structure in neutral gas, which is in agreement within a number of other observations; and (II) the recurrent problems of reproducing realistic line profiles from hydrodynamical simulations may be due to their inability to resolve small-scale structure, which causes simulations to underestimate the effective covering factor of neutral gas clouds. The movie associated to Fig. B.2 is available at http://www.aanda.org

  16. Multi-level modelling of the response of the ultraminiature proportional counter: gas gain phenomena and pulse height spectra

    International Nuclear Information System (INIS)

    Olko, P.; Moutarde, C.; Segur, P.

    1995-01-01

    The ultraminiature proportional counters, UMC, unique radiation detectors for monitoring high intensity therapy fields, designed by Kliauga and operated at Columbia University (USA), have yielded a number of pulse height distributions for photons, neutrons and ions at simulated diameters of 5-50 nm. Monte Carlo calculations of the gas gain in such a counter questioned the possibility of achieving proportionally at such low simulated diameters. The response of the UMC has now been modelled taking into account both fluctuations of energy deposited in the counter volume and its calculated gas gain. Energy deposition was calculated using the MOCA-14, MOCA-8 and TRION codes, whereby distributions of ionisations d(j) after irradiations with 137 Cs, 15 MeV neutrons and 7 MeV.amu -1 deuterons were obtained. Monte Carlo calculations of electron avalanches in UMC show that the size of the single-electron avalanche P(n) reaching the anode depends strongly on the location of the primary ionisation within the counter volume. Distributions of the size of electron avalanches for higher numbers of primary ionisations, P *j (n), were obtained by successive convolutions of P(n). Finally, the counter response was obtained by weighting P *j (n) over d(j) distributions. On comparing the measured and calculated spectra it was concluded that the previously proposed single-electron peak calibration method might not be valid for the UMC due to the excessive width and overlap of electron avalanche distributions. Better agreement between the measured and calculated spectra is found if broader electron avalanche distributions than those used in the present calculations, are assumed. (author)

  17. Valve for gas centrifuges

    Science.gov (United States)

    Hahs, Charles A.; Burbage, Charles H.

    1984-01-01

    The invention is a pneumatically operated valve assembly for simultaneously (1) closing gas-transfer lines connected to a gas centrifuge or the like and (2) establishing a recycle path between two of the lines so closed. The valve assembly is especially designed to be compact, fast-acting, reliable, and comparatively inexpensive. It provides large reductions in capital costs for gas-centrifuge cascades.

  18. Development of an on-line low gas pressure cell for laser ablation-ICP-mass spectrometry

    International Nuclear Information System (INIS)

    Hirata, Takafumi

    2007-01-01

    An on-line low gas pressure cell device has been developed for elemental analysis using laser ablation-ICP-mass spectrometry (LA-ICPMS). Ambient gas in the sample cell was evacuated by a constant-flow diaphragm pump, and the pressure of the sample cell was controlled by changing the flow rate of He-inlet gas. The degree of sample re-deposition around the ablation pit could be reduced when the pressure of the ambient gas was lower than 50 kPa. Produced sample aerosol was drawn and taken from the outlet of the diaphragm pump, and directly introduced into the ICP ion source. The flow rate of He gas controls not only the gas pressure in the sample cell, but also the transport efficiency of the sample particles from the cell to the ICP, and the gas flow rate must be optimized to maximize the signal intensity of the analytes. The flow rates of the He carrier and Ar makeup gas were tuned to maximize the signal intensity of the analytes, and in the case of 238 U from the NIST SRM610 glass material, the signal intensity could be maximized with gas flow rates of 0.4 L/min for He and 1.2 L/min for Ar. The resulting gas pressure in the cell was 30-35 kPa. Using the low gas pressure cell device, the stability in the signal intensities and the resulting precision in isotopic ratio measurements were evaluated. The signal intensity profile of 63 Cu obtained by laser ablation from a metallic sample (NIST SRM976) demonstrated that typical spikes in the transient signal, which can become a large source of analytical error, were no longer found. The resulting precision in the 65 Cu/ 63 Cu ratio measurements was 2-3% (n=10, 2SD), which was half on the level obtained by laser ablation under atmospheric pressure (6-10%). The newly developed low-pressure cell device provides easier optimization of the operational conditions, together with smaller degrees of sample re-deposition and better stability in the signal intensity, even from a metallic sample. (author)

  19. Beam Transfer Line Design for a Plasma Wakefield Acceleration Experiment (AWAKE) at the CERN SPS

    CERN Document Server

    Bracco, C; Brethoux, D; Clerc, V; Goddard, B; Gschwendtner, E; Jensen, L K; Kosmicki, A; Le Godec, G; Meddahi, M; Muggli, P; Mutin, C; Osborne, O; Papastergiou, K; Pardons, A; Velotti, F M; Vincke, H

    2013-01-01

    The world’s first proton driven plasma wakefield acceleration experiment (AWAKE) is presently being studied at CERN. The experimentwill use a high energy proton beam extracted from the SPS as driver. Two possible locations for installing the AWAKE facility were considered: the West Area and the CNGS beam line. The previous transfer line from the SPS to the West Area was completely dismantled in 2005 and would need to be fully re-designed and re-built. For this option, geometric constraints for radiation protection reasons would limit the maximum proton beam energy to 300 GeV. The existing CNGS line could be used by applying only minor changes to the lattice for the final focusing and the interface between the proton beam and the laser, required for plasma ionisation and bunch-modulation seeding. The beam line design studies performed for the two options are presented.

  20. In vitro oxygen-dependent survival of two human cell lines after combined radiations tirapazamin and cisplatin

    International Nuclear Information System (INIS)

    Lartigau, E.; Stern, S.; Guichard, M.

    2000-01-01

    Recent data have shown that the in vitro and in vivo cytotoxicity of bioreductive drugs could be significantly cytotoxicity of bioreductive drugs could be significantly increased by combination with ionising radiation or chemotherapy. Various parameters such as oxygen tension and timing of administration of the drugs could play a crucial role in the efficacy of combined treatment modalities. The aim of this study was to define the oxygen dependency of cell survival after in vitro irradiation and incubation with tirapazamin, a bioreductive drug, and cisplatin given alone or simultaneously. Two human cell lines were studied: one cell line sensitive to tirapazamin, Na11+, a pigmented melanoma with a high percentage of hypoxic cells, and a less sensitive cell line to tirapazamin, HRT18, a rectal adenocarcinoma. Gas changes were made to study cell survival at four different oxygen concentrations (pO 2 ): air (20.9 % O 2 ), 10.2 and 0.2 %. Cells were incubated with tirapazamin and cisplatin alone or combined for one hour at 37 deg C, then irradiated and cultured. For Na11+, cell survival after irradiation was comparable in air and at 10 % oxygen with the two drugs given alone or combined. At 2 and 0.2 % oxygen, cell killing was largely increased by tirapazamin and was not modified by the addition of cisplatin. For HRT18, cell survival was not modified when cisplatin was added to radiation, whatever the oxygen partial pressure. At low pO 2 (2 and 0.2 %) the cytotoxic effect of tirapazamin was not significantly decreased by the addition of cisplatin. When cytotoxic and bioreductive drugs are combined to radiation, the magnitude of the observed effect is highly dependent on the partial oxygen pressure and on the sensitivity of the cell line to the individual drugs. This has very important implications for clinical strategies based on combined chemo-radiotherapy. (authors)

  1. On-line ultrasonic gas entrainment monitor

    International Nuclear Information System (INIS)

    Day, C.K.; Pedersen, H.N.

    1978-01-01

    Apparatus employing ultrasonic energy for detecting and measuring the quantity of gas bubbles present in liquids being transported through pipes is described. An ultrasonic transducer is positioned along the longitudinal axis of a fluid duct, oriented to transmit acoustic energy radially of the duct around the circumference of the enclosure walls. The back-reflected energy is received centrally of the duct and interpreted as a measure of gas entrainment. One embodiment employs a conical reflector to direct the transmitted acoustic energy radially of the duct and redirect the reflected energy back to the transducer for reception. A modified embodiment employs a cylindrical ultrasonic transducer for this purpose

  2. Characterisation of exposure to non-ionising electromagnetic fields in the Spanish INMA birth cohort: Study protocol

    NARCIS (Netherlands)

    M. Gallastegi (Mara); M. Guxens Junyent (Mònica); A. Jiménez-Zabala (Ana); I. Calvente (Irene); M. Fernández (Marta); L. Birks (Laura); B. Struchen (Benjamin); M. Vrijheid (Martine); M. Estarlich (Marisa); M.F. Fernandez (Mariana); M. Torrent (Maties); F. Ballester (Ferran); J.J. Aurrekoetxea (Juan José); J. Ibarluzea (Jesús); D. Guerra (David); J. González (Julián); M. Röösli (Martin); L. Santa-Marina (Loreto)

    2016-01-01

    textabstractBackground: Analysis of the association between exposure to electromagnetic fields of non-ionising radiation (EMF-NIR) and health in children and adolescents is hindered by the limited availability of data, mainly due to the difficulties on the exposure assessment. This study protocol

  3. Controllable isotope fractionation with thermal ionisation mass-spectrometers

    International Nuclear Information System (INIS)

    Hebeda, E.H.

    1980-01-01

    Isotopic ratios measured with thermal ionisation mass-spectrometers are biased by fractionation effects. A sample must therefore be analyzed according to the same procedures as applied for the analysis of the standard reference material. A comparison of the behaviour of the sample with that of the standard can then be used as a criterion whether the analytical results are acceptable or not. In this way it is possible to obtain reproducibilities similar to those for elements acceptable or not. In this way it is possible to obtain reproducibilities similar to those for elements where the fractionation can be determined by an internal standard. This procedure of controlled fractionation is demonstrated by means of the 88 Sr/ 86 Sr ratios measured on geological samples and the SRM 987 standard. (orig.)

  4. Tumour induction by small doses of ionised radiation

    International Nuclear Information System (INIS)

    Putten, L.M. van

    1980-01-01

    The effect of low doses of ionised radiation on tumour induction in animals is discussed. It is hypothesised that high doses of radiation can strongly advance tumour induction from the combination of a stimulated cell growth, as a reaction to massive cell killing, and damage to DNA in the cell nuclei. This effect has a limit below which the radiation dose causes a non-significant amount of dead cells. However in animals where through other reasons, a chronic growth stimulation already exists, only one effect, the damage of DNA, is necessary to induce tumours. A linear dose effect without a threshold level applies in these cases. Applying this hypothesis to man indicates that calculating low dose effects by linear extrapolation of high dose effects is nothing more than a reasonable approximation. (C.F.)

  5. Protection of the environment from ionising radiation: ethical issues

    International Nuclear Information System (INIS)

    Oughton, D.

    2002-01-01

    The paper identifies some of the main ethical issues concerning the protection of the environment from radiation and suggests ways in which ethics can aid in developing a system of protection. After a presentation of background on ethical theory and environmental ethics, three main issues related to practical environmental protection are discussed: First, the question of who or what has moral standing; second the appropriate level of protection; and third compatibility with other environmental stressors. In summary, the paper argues that there are strong ethical grounds for efforts to provide for the protection of the environment and that, all other things being equal, there is no reason to treat ionising radiation differently to other environmental stressors. (author)

  6. Audio-frequency noise emissions from high-voltage overhead power lines

    International Nuclear Information System (INIS)

    Semmler, M.; Straumann, U.; Roero, C.; Teich, T. H.

    2005-01-01

    This article discusses the noise-emissions caused by high-voltage overhead power lines that can occur under certain atmospheric conditions. These emissions, caused by electric discharges around the conductors, can achieve disturbing values, depending on the conditions prevailing at the time in question. The causes of the discharges are examined and the ionisation processes involved are looked at. The parameters influencing the discharges are discussed and measures that can be taken to reduce such audio-frequency emissions are looked at. The authors note that a reduction of peripheral field strengths can reduce emissions and that hydrophilic coatings can lead to faster reduction of such effects after rainfall

  7. What's in the Wind? Determining the Properties of Outflowing Gas in Powerful Broad Absorption Line Quasars

    Science.gov (United States)

    Leighly, Karen

    2017-08-01

    A significant fraction of quasars exhibits blueshifted broadabsorption lines (BALs) in their rest-UV spectra, indicating powerfuloutflows emerging from the central engine. These outflows may removeangular momentum to enable black hole growth, enrich the intergalacticmedium with metals, and trigger quenching of star formation ingalaxies. Despite years of study, the physical conditions of theoutflowing gas are poorly understood. The handful of objects that havebeen subjected to detailed analysis are atypical and characterized byrelatively narrow lines where blending is unimportant. However,investigating more powerful BAL quasars will give us better insightinto the types of outflows much more likely to impact galaxyevolution.SimBAL is a novel spectral synthesis fitting method for BAL quasarsthat uses Bayesian model calibration to compare synthetic to observedspectra. With the model inputs of ionization parameter, columndensity, and covering fraction specified, the gas properties givingrise to the BAL features can be determined. We propose to applySimBAL to archival spectra of a sample of 14 luminous BAL quasars to characterize their bulk outflow properties as a function of velocityfor the first time. Our results will show the range of parameterstypical of powerful outflows, an essential step towards constrainingthe physics behind quasar winds and thus their impact on theirenvironments.

  8. Systematization of by-product plant. (1) Development of on-line analyzers for treatment of gas liquor

    Energy Technology Data Exchange (ETDEWEB)

    Matsumura, Susumu; Taketomi, Hirofumi; Ohashi, Shigeru [Nippon Kokan K.K., Tokyo (Japan)

    1988-04-07

    As a part of systematization of absorption and refinery processing installation for coke oven gas, on-line analyzers for gas liquor treatment with activated sludge were developed and established. A T-NH{sub 3} analyzer using a potential difference titration method was equipped to control NH{sub 3} which had a bad influence upon activated sludge. The oxygen intake rate is measured with an activity measuring instrument in order to get the activity condition of bacteria. The SCN concentration of precipitator outlet solution is measured with an SCN(thiocyanogen) measuring instrument so that conditions of bacteria can be seized. An absorptiometry with ferric chloride is used to analyze it. For a COD measuring instrument, precipitator outlet solution is used and analysis with the JIS method is entirely automated. As a transparency measuring instrument, a color-difference colorimeter is used instead of the former instrument made of glass. According to the collected data, charged coal conditions, and operating conditions of coke oven, the process computer does the calculation for optimization and indicates operation control guidances to the operator. Automated on -line analyzers are useful to save a great deal of labor and contribute to the control and stabilization of operations. 9 figs., 1 tab.

  9. The ionisation of the primeval plasma at the time of recombination

    International Nuclear Information System (INIS)

    Jones, B.J.T.; Wyse, R.F.G.

    1984-09-01

    We rederive the equations for the ionisation of the cosmic plasma during the recombination period, correcting some of the earlier work and refining some approximations inherent in those treatments and allow for the possibility that the universe may contain substantial amounts of non-baryonic matter (the cosmic density parameter Ωsub(T) may be greater than the baryonic contribution Ωsub(B)). The results are tabulated for various Ωsub(T)h 2 and Ωsub(B)h 2 and an assumed present day radiation temperature T 0 =2.7 K. (orig./WL)

  10. Monitoring of radon gas in caves of the Yorkshire Dales, United Kingdom

    International Nuclear Information System (INIS)

    Langridge, D; Stokes, R P; Jackson, C P

    2010-01-01

    A number of vocational training courses are held in caves in the Yorkshire Dales region of the United Kingdom. The instructors and students involved in these courses have the potential to be exposed to enhanced levels of radon ( 222 Rn) and its progeny as a result of their occupations. A prior radiological risk assessment for the training courses recommended that an environmental monitoring programme be carried out to establish the radon concentrations in the caves, and that the caving instructors wear personal radon dosemeters. Radon gas concentrations varied seasonally, being at their highest in summer and their lowest in winter. The lowest result was 40 Bq m -3 recorded in Lower Longchurn cave during winter, whilst the highest result was 4440 Bq m -3 recorded in Crackpot cave during the summer. As the individuals involved in the caving are entering atmospheres with radon gas concentrations in excess of 400 Bq m -3 , the Ionising Radiation Regulations 1999 (GB Parliament 2000 Ionising Radiations Regulations 1999 (London: Stationary Office) SI 1999/3232) apply. A system of work is therefore in place to control exposure to radon. This system of work stipulates an initial dose investigation level of 1 mSv, a second dose investigation level of 2 mSv and an annual dose limit of 6 mSv. The highest annual dose recorded to date is 2.2 mSv, although the average (median) annual dose is only 0.5 mSv.

  11. FREQUENCY OF CHROMOSOMAL ABERRATIONS AND MICRONUCLEI IN HORSE LYMPHOCYTES FOLLOWING IN VITRO EXPOSURE TO LOW DOSE IONISING RADIATION

    Directory of Open Access Journals (Sweden)

    Dunja Rukavina

    2012-07-01

    Full Text Available Ionising radiation is known to cause chromosomal instability, which is observed as increased frequency of chromosomal aberration and micronuclei. These are listed as reliable criteria in biological dosimetry. Numerous experiments conducted on both animal and plant models demonstrated that increase in radiation dosage is followed by increased mutation frequency, and that mutations occur even at the lowest exposure. We used horse blood in vitro irradiated by low doses of ionizing radiation. Cultivation of peripheral blood lymphocytes and micronucleus test were used as biomarkers of genetic damage. The observed aberrations were recorded and classified in accordance with the International System of Cytogenetic Nomenclature. Micronuclei were identified on the basis of criteria proposed by Fenech et al. (8. Analysis of chromosomal aberration showed increased frequency of aberrations in blood cultures exposed to 0,1 Gy and 0,2 Gy compared to the controls. Microscopic analysis of chromosomal damage in in vitro micronucleus test revealed that the applied radiation dose induced micronuclei while no binucleated cells with micronuclei were found in lymphocytes that were not irradiated. In this paper we analysed the influence of low dose ionising radiation on frequency of chromosomal aberration and micronuclei in horse lymphocytes following in vitro exposure to X-rays (0,1 Gy and 0,2 Gy. Key words: chromosomal aberrations, micronuclei, ionising radiation, horse lymphocytes

  12. LIAD-fs: A novel method for studies of ultrafast processes in gas phase neutral biomolecules

    International Nuclear Information System (INIS)

    Calvert, C R; Kelly, O; Duffy, M J; Belshaw, L; King, R B; Williams, I D; Greenwood, J B

    2012-01-01

    A new experimental technique for femtosecond (fs) pulse studies of gas phase biomolecules is reported. Using Laser-Induced Acoustic Desorption (LIAD) to produce a plume of neutral molecules, a time-delayed fs pulse is employed for ionisation/fragmentation, with subsequent products extracted and mass analysed electrostatically. By varying critical laser pulse parameters, this technique can be used to implement control over molecular fragmentation for a range of small biomolecules, with specific studies of amino acids demonstrated.

  13. Improved communication, understanding of risk perception and ethics related to ionising radiation.

    Science.gov (United States)

    Perko, Tanja; Raskob, Wolfgang; Jourdain, Jean-Rene

    2016-06-06

    In Europe today, institutions, media and the general public exchange information about ionizing radiation and associated risks. However, communication about ionising radiation with the general public has to be further improved, as has been previously highlighted by international responses to the 2011 accident in Japan. This article reports the main activities and findings in this field from the following three FP7 projects: EAGLE, PREPARE and OPERRA and discussed by a broad spectrum of stakeholders at the conference RICOMET 2015. These projects, among other aims, also investigate how communication about ionising radiation in different fields could be improved and harmonised, how radiological risks are perceived, how to encourage ethical considerations in all fields of nuclear applications and what kind of transdisciplinary research is needed. The projects relate to several domains; the first relates to education, training and communication, the second to nuclear emergency preparedness and response, and the third to research and development in the radiation protection field. Incorporation of stakeholder engagement activities such as the RICOMET conference broadens social and ethical aspects and takes them into account during coordination activities as well as during core scientific and nuclear research and development performed in the projects. These activities offered opportunities for moving closer to a citizen-centred ideal of risk communication in particular and nuclear research and development in general.

  14. The evolution of young HII regions. I. Continuum emission and internal dynamics

    Science.gov (United States)

    Klaassen, P. D.; Johnston, K. G.; Urquhart, J. S.; Mottram, J. C.; Peters, T.; Kuiper, R.; Beuther, H.; van der Tak, F. F. S.; Goddi, C.

    2018-04-01

    Context. High-mass stars form in much richer environments than those associated with isolated low-mass stars, and once they reach a certain mass, produce ionised (HII) regions. The formation of these pockets of ionised gas are unique to the formation of high-mass stars (M > 8 M⊙), and present an excellent opportunity to study the final stages of accretion, which could include accretion through the HII region itself. Aim. This study of the dynamics of the gas on both sides of these ionisation boundaries in very young HII regions aims to quantify the relationship between the HII regions and their immediate environments. Methods: We present high-resolution ( 0.5″) ALMA observations of nine HII regions selected from the red MSX source survey with compact radio emission and bolometric luminosities greater than 104 L⊙. We focus on the initial presentation of the data, including initial results from the radio recombination line H29α, some complementary molecules, and the 256 GHz continuum emission. Results: Of the six (out of nine) regions with H29α detections, two appear to have cometary morphologies with velocity gradients across them, and two appear more spherical with velocity gradients suggestive of infalling ionised gas. The remaining two were either observed at low resolution or had signals that were too weak to draw robust conclusions. We also present a description of the interactions between the ionised and molecular gas (as traced by CS (J = 5 - 4)), often (but not always) finding the HII region had cleared its immediate vicinity of molecules. Conclusions: Of our sample of nine, the observations of the two clusters expected to have the youngest HII regions (from previous radio observations) are suggestive of having infalling motions in the H29α emission, which could be indicative of late stage accretion onto the stars despite the presence of an HII region. Table A.2 is also available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (http://130

  15. Using the van der Waals broadening of the spectral atomic lines to measure the gas temperature of an argon microwave plasma at atmospheric pressure

    International Nuclear Information System (INIS)

    Yubero, C.; Dimitrijevic, M.S.; Garcia, M.C.; Calzada, M.D.

    2007-01-01

    The ro-vibrational emission spectra of the molecular species are usually used to measure the gas temperature of a discharge at atmospheric pressure. However, under some experimental conditions, it is difficult to detect them. In order to overcome this difficulty and obtain the temperature, there are methods based on the relation between the gas temperature and the van der Waals broadening of argon atomic spectral lines with a Stark contribution negligible. In this work, we propose a method based on this relation but for lines with a Stark broadening comparable with the van der Waals one

  16. A New Radio Spectral Line Survey of Planetary Nebulae: Exploring Radiatively-driven Heating and Chemistry of Molecular Gas

    Science.gov (United States)

    Bublitz, Jesse; Kastner, Joel H.; Santander-García, Miguel; Montez, Rodolfo; Alcolea, Javier; Balick, Bruce; Bujarrabal, Valentín

    2018-01-01

    We report the results of a survey of mm-wave molecular line emission from nine nearby (Radioastronomie Millimétrique (IRAM) 30 m telescope. Our sample comprises molecule-rich PNe spanning a wide range of central star UV luminosities as well as central star and nebular X-ray emission properties. Nine molecular line frequencies were chosen to investigate the molecular chemistry of these nebulae. New detections of one or more of five molecules -- the molecular mass tracer 13CO and the chemically important trace species HCO+, CN, HCN, and HNC -- were made in at least one PN. We present analysis of emission line flux ratios that are potential diagnostics of the influence that ultraviolet and X-ray radiation have on the chemistry of residual molecular gas in PNe.

  17. ALARA - the contribution of the proposed new ionising radiations regulations

    International Nuclear Information System (INIS)

    Young, T.O.

    1982-01-01

    This paper describes the proposed regulatory requirements and appropriate guidance contained in the approved code of practice on ionising radiations which are designed to support and help reach the objective of keeping radiation doses as low as reasonably achievable. This is discussed against the background of factory legislation, and the way in which the form of the proposed legislation handles this topic is illustrated. The measures required by the proposed legislation are reviewed, both as direct measures designed to create a climate of dose reduction, and as general measures designed to achieve the same end by means of a wide range of requirements. (author)

  18. Exploring Learners' Conceptual Resources: Singapore a Level Students' Explanations in the Topic of Ionisation Energy

    Science.gov (United States)

    Taber, Keith S.; Tan, Kim Chwee Daniel

    2007-01-01

    This paper describes findings from a study to explore Singapore A-level (Grades 11 and 12, 16-19 yr old) students' understanding of ionisation energy, an abstract and complex topic that is featured in school chemistry courses. Previous research had reported that students in the United Kingdom commonly use alternative notions based on the perceived…

  19. Molecular Line Emission as a Tool for Galaxy Observations (LEGO). I. HCN as a tracer of moderate gas densities in molecular clouds and galaxies

    Science.gov (United States)

    Kauffmann, Jens; Goldsmith, Paul F.; Melnick, Gary; Tolls, Volker; Guzman, Andres; Menten, Karl M.

    2017-09-01

    Trends observed in galaxies, such as the Gao & Solomon relation, suggest a linear relationship between the star formation rate and the mass of dense gas available for star formation. Validation of such trends requires the establishment of reliable methods to trace the dense gas in galaxies. One frequent assumption is that the HCN (J = 1-0) transition is unambiguously associated with gas at H2 densities ≫ 104 cm-3. If so, the mass of gas at densities ≫ 104 cm-3 could be inferred from the luminosity of this emission line, LHCN (1-0). Here we use observations of the Orion A molecular cloud to show that the HCN (J = 1-0) line traces much lower densities 103 cm-3 in cold sections of this molecular cloud, corresponding to visual extinctions AV ≈ 6 mag. We also find that cold and dense gas in a cloud like Orion produces too little HCN emission to explain LHCN (1-0) in star forming galaxies, suggesting that galaxies might contain a hitherto unknown source of HCN emission. In our sample of molecules observed at frequencies near 100 GHz (also including 12CO, 13CO, C18O, CN, and CCH), N2H+ is the only species clearly associated with relatively dense gas.

  20. Dedicated Trigger for Highly Ionising Particles at ATLAS

    CERN Document Server

    Katre, Akshay; The ATLAS collaboration

    2015-01-01

    In 2012, a novel strategy was designed to detect signatures of Highly Ionising Particles (HIPs) such as magnetic monopoles, dyons or Q-balls with ATLAS. A dedicated trigger was developed and deployed for proton-proton collisions at a centre of mass energy of 8 TeV. It uses the Transition Radiation Tracker (TRT) system, applying an algorithm distinct from standard tracking ones. The high threshold (HT) readout capability of the TRT is used to distinguish HIPs from other background processes. The trigger requires significantly lower energy depositions in the electromagnetic calorimeters and is thereby capable of probing a larger range of HIP masses and charges. A description of the algorithm for this newly developed trigger is presented, along with a comparitive study of its performance during the 2012 data-taking period with respect to previous efforts.

  1. Theoretical study of a weakly ionised gas in a uniform constant electric field

    International Nuclear Information System (INIS)

    Segur, Pierre.

    1974-01-01

    The collision operators of the Boltzmann equation are expressed in terms of the transition probabilities for a Lorentz gas and inelastic type collisions in the case of conservation and non-conservation of the initial number of particles. These operators are approximately expressed when the mass ratio of the present particles is weak. The expressions obtained are valid for any particle distribution functions. A series expansion in spherical harmonics is effected for these operators. The Boltzmann equation is then solved for the case of a steady homogeneous medium when the electric field effect is lower than that of collisions. A resolving method is then proposed for the case where the electric field and collisions play comparable roles. Analytical expressions are given for the distribution functions in terms of asymptotic solutions valid for any type of cross section. A steady heterogenous medium is then studied by a direct numerical solution of the Boltzmann equation, for high values of the electric field/ pressure ratio. The existence of a single lattice of characteristic directions is established as well as a distribution function representing in phase space a band structure characteristic of the presence of inelastic collisions. The electron motion is simulated using a Monte-Carlo method. The calculations being effected in helium, a bibliography of the cross sections for this gas is given [fr

  2. Absolute 3PO triple differential cross sections for electron-helium Wannier threshold ionisation

    International Nuclear Information System (INIS)

    Carruthers, D.R.J.; Crothers, D.S.F.

    1992-01-01

    The uniform semiclassical approximation of Crothers is employed to find a final-state 3 P O wave function for threshold electron impact ionisation of helium. The Kohn variational principle is applied perturbatively to evaluate the scattering amplitude and hence the absolute 3 P O contribution to the triple differential cross sections. These plus the previous absolute singlet results of Crothers are compared favourably with the relative experimental results of Selles et al. (orig.)

  3. EPR spectroscopy for the detection of foods treated with ionising radiation

    International Nuclear Information System (INIS)

    Stachowicz, W.; Burlinska, G.; Michalik, J.; Dziedzic-Goclawska, A.; Ostrowski, K.

    1996-01-01

    The advantage of electron paramagnetic resonance spectroscopy (EPR or ESR) as a tool for the control of irradiated food lies in its sensitivity and accuracy. Ionising radiation produces, in irradiated materials, paramagnetic species of different kinds, i.e. radicals, radical-ions and paramagnetic centres, which can be measured by EPR but most of them are not stable enough to be used for the detection of irradiation. It is because radiation-induced paramagnetic species are thermodynamically less stable than surrounding molecules and take part in fast radiolytic reactions leading to the formation of final diamagnetic products that they are not detectable by the EPR method. Most of organic radicals produced by radiation in the liquid phase ae unstable but if the unpaired electron is incorporated into the complex polymeric system as in peptides and polysaccharides and is structurally isolated from the water, its stability is markedly increased. Since 1954 it is known that ionising radiation produces paramagnetic entities in biological materials, cells and tissues and some are stable enough to be observed by EPR spectroscopy at room temperature. The present paper describes and discusses that part of results obtained by this group during the period of ADMIT activity (1989-94) which are original and may be useful to those who will be working in the near future on the development of uniform control systems for the detection of irradiated food. The intention was to focus attention on these facts and data which influence the certainty of the detection in both positive and negative manner. (author)

  4. On-line monitoring of trace compounds in the flue gas of an incineration pilot plant: Formation of polycyclic aromatic hydrocarbons

    International Nuclear Information System (INIS)

    Heger, H. J.; Zimmermann, R.; Dorfner, R.; Kettrup, A.; Boesl, U.

    1998-01-01

    Laser mass spectrometry is applied for on-line analysis of PAHs from a complex flue gas matrix in the combustion chamber of an incineration plant. Process monitoring of industrial processes can be performed. New insights into the formation of toxic combustion byproducts are possible

  5. A Survey of Metal Lines at High Redshift. II. SDSS Absorption Line Studies—O VI Line Density, Space Density, and Gas Metallicity at z abs ~ 3.0

    Science.gov (United States)

    Frank, S.; Mathur, S.; Pieri, M.; York, D. G.

    2010-09-01

    We have analyzed a large data set of O VI absorber candidates found in the spectra of 3702 Sloan Digital Sky Survey (SDSS) quasars, focusing on a subsample of 387 active galactic nuclei sight lines with an average S/N >=5.0, allowing for the detection of absorbers above a rest-frame equivalent width limit of W r >= 0.19 Å for the O VI 1032 Å component. Accounting for random interlopers mimicking an O VI doublet, we derive for the first time a secure lower limit for the redshift number density ΔN/Δz for redshifts z abs >= 2.8. With extensive Monte Carlo simulations, we quantify the losses of absorbers due to blending with the ubiquitous Lyα forest lines and estimate the success rate of retrieving each individual candidate as a function of its redshift, the emission redshift of the quasar, the strength of the absorber, and the measured signal-to-noise ratio (S/N) of the spectrum by modeling typical Lyman forest spectra. These correction factors allow us to derive the "incompleteness and S/N-corrected" redshift number densities of O VI absorbers: ΔN O VI,c /Δzc (2.8 secure lower limit for the contribution of O VI to the closure mass density at the redshifts probed here: ΩO VI (2.8 = 1.9 × 10-8 h -1. We show that the strong lines we probe account for over 65% of the mass in the O VI absorbers; the weak absorbers, while dominant in line number density, do not contribute significantly to the mass density. Making a conservative assumption about the ionization fraction, {O VI}/{O}, and adopting the Anders & Grevesse solar abundance values, we derive the mean metallicity of the gas probed in our search: ζ(2.8 = 3.6 × 10-4 h, in good agreement with other studies. These results demonstrate that large spectroscopic data sets such as SDSS can play an important role in QSO absorption line studies, in spite of the relatively low resolution.

  6. A SURVEY OF METAL LINES AT HIGH REDSHIFT. II. SDSS ABSORPTION LINE STUDIES-O VI LINE DENSITY, SPACE DENSITY, AND GAS METALLICITY AT zabs ∼ 3.0

    International Nuclear Information System (INIS)

    Frank, S.; Mathur, S.; Pieri, M.; York, D. G.

    2010-01-01

    We have analyzed a large data set of O VI absorber candidates found in the spectra of 3702 Sloan Digital Sky Survey (SDSS) quasars, focusing on a subsample of 387 active galactic nuclei sight lines with an average S/N ≥5.0, allowing for the detection of absorbers above a rest-frame equivalent width limit of W r ≥ 0.19 A for the O VI 1032 A component. Accounting for random interlopers mimicking an O VI doublet, we derive for the first time a secure lower limit for the redshift number density ΔN/Δz for redshifts z abs ≥ 2.8. With extensive Monte Carlo simulations, we quantify the losses of absorbers due to blending with the ubiquitous Lyα forest lines and estimate the success rate of retrieving each individual candidate as a function of its redshift, the emission redshift of the quasar, the strength of the absorber, and the measured signal-to-noise ratio (S/N) of the spectrum by modeling typical Lyman forest spectra. These correction factors allow us to derive the 'incompleteness and S/N-corrected' redshift number densities of O VI absorbers: ΔN O V I,c /Δz c (2.8 O V I,c /Δz c (3.2 O V I,c /Δz c (3.6 O V I (2.8 -8 h -1 . We show that the strong lines we probe account for over 65% of the mass in the O VI absorbers; the weak absorbers, while dominant in line number density, do not contribute significantly to the mass density. Making a conservative assumption about the ionization fraction, O VI /O, and adopting the Anders and Grevesse solar abundance values, we derive the mean metallicity of the gas probed in our search: ζ(2.8 -4 h, in good agreement with other studies. These results demonstrate that large spectroscopic data sets such as SDSS can play an important role in QSO absorption line studies, in spite of the relatively low resolution.

  7. Characterisation of the Muon Beams for the Muon Ionisation Cooling Experiment

    CERN Document Server

    Adams, D.; Alekou, A.; Apollonio, M.; Asfandiyarov, R.; Back, J.; Barber, G.; Barclay, P.; de Bari, A.; Bayes, R.; Bayliss, V.; Bertoni, R.; Blackmore, V.J.; Blondel, A.; Blot, S.; Bogomilov, M.; Bonesini, M.; Booth, C.N.; Bowring, D.; Boyd, S.; Bradshaw, T.W.; Bravar, U.; Bross, A.D.; Capponi, M.; Carlisle, T.; Cecchet, G.; Charnley, G.; Cobb, J.H.; Colling, D.; Collomb, N.; Coney, L.; Cooke, P.; Courthold, M.; Cremaldi, L.M.; DeMello, A.; Dick, A.; Dobbs, A.; Dornan, P.; Fayer, S.; Filthaut, F.; Fish, A.; Fitzpatrick, T.; Fletcher, R.; Forrest, D.; Francis, V.; Freemire, B.; Fry, L.; Gallagher, A.; Gamet, R.; Gourlay, S.; Grant, A.; Graulich, J.S.; Griffiths, S.; Hanlet, P.; Hansen, O.M.; Hanson, G.G.; Harrison, P.; Hart, T.L.; Hartnett, T.; Hayler, T.; Heidt, C.; Hills, M.; Hodgson, P.; Iaciofano, A.; Ishimoto, S.; Kafka, G.; Kaplan, D.M.; Karadzhov, Y.; Kim, Y.K.; Kolev, D.; Kuno, Y.; Kyberd, P.; Lau, W.; Leaver, J.; Leonova, M.; Li, D.; Lintern, A.; Littlefield, M.; Long, K.; Lucchini, G.; Luo, T.; Macwaters, C.; Martlew, B.; Martyniak, J.; Middleton, S.; Moretti, A.; Moss, A.; Muir, A.; Mullacrane, I.; Nebrensky, J.J.; Neuffer, D.; Nichols, A.; Nicholson, R.; Nugent, J.C.; Onel, Y.; Orestano, D.; Overton, E.; Owens, P.; Palladino, V.; Palmer, R.B.; Pasternak, J.; Pastore, F.; Pidcott, C.; Popovic, M.; Preece, R.; Prestemon, S.; Rajaram, D.; Ramberger, S.; Rayner, M.A.; Ricciardi, S.; Richards, A.; Roberts, T.J.; Robinson, M.; Rogers, C.; Ronald, K.; Rubinov, P.; Rucinski, R.; Rusinov, I.; Sakamoto, H.; Sanders, D.A.; Santos, E.; Savidge, T.; Smith, P.J.; Snopok, P.; Soler, F.J.P.; Stanley, T.; Summers, D.J.; Takahashi, M.; Tarrant, J.; Taylor, I.; Tortora, L.; Torun, Y.; Tsenov, R.; Tunnell, C.D.; Vankova, G.; Verguilov, V.; Virostek, S.; Vretenar, M.; Walaron, K.; Watson, S.; White, C.; Whyte, C.G.; Wilson, A.; Wisting, H.; Zisman, M.

    2013-01-01

    A novel single-particle technique to measure emittance has been developed and used to characterise seventeen different muon beams for the Muon Ionisation Cooling Experiment (MICE). The muon beams, whose mean momenta vary from 171 to 281 MeV/c, have emittances of approximately 1.5--2.3 \\pi mm-rad horizontally and 0.6--1.0 \\pi mm-rad vertically, a horizontal dispersion of 90--190 mm and momentum spreads of about 25 MeV/c. There is reasonable agreement between the measured parameters of the beams and the results of simulations. The beams are found to meet the requirements of MICE.

  8. Characterisation of the muon beams for the Muon Ionisation Cooling Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Adams, D.; et al.,

    2013-10-01

    A novel single-particle technique to measure emittance has been developed and used to characterise seventeen different muon beams for the Muon Ionisation Cooling Experiment (MICE). The muon beams, whose mean momenta vary from 171 to 281 MeV/c, have emittances of approximately 1.5--2.3 \\pi mm-rad horizontally and 0.6--1.0 \\pi mm-rad vertically, a horizontal dispersion of 90--190 mm and momentum spreads of about 25 MeV/c. There is reasonable agreement between the measured parameters of the beams and the results of simulations. The beams are found to meet the requirements of MICE.

  9. Gas dynamic design of the pipe line compressor with 90% efficiency. Model test approval

    Science.gov (United States)

    Galerkin, Y.; Rekstin, A.; Soldatova, K.

    2015-08-01

    Gas dynamic design of the pipe line compressor 32 MW was made for PAO SMPO (Sumy, Ukraine). The technical specification requires compressor efficiency of 90%. The customer offered favorable scheme - single-stage design with console impeller and axial inlet. The authors used the standard optimization methodology of 2D impellers. The original methodology of internal scroll profiling was used to minimize efficiency losses. Radically improved 5th version of the Universal modeling method computer programs was used for precise calculation of expected performances. The customer fulfilled model tests in a 1:2 scale. Tests confirmed the calculated parameters at the design point (maximum efficiency of 90%) and in the whole range of flow rates. As far as the authors know none of compressors have achieved such efficiency. The principles and methods of gas-dynamic design are presented below. The data of the 32 MW compressor presented by the customer in their report at the 16th International Compressor conference (September 2014, Saint- Petersburg) and later transferred to the authors.

  10. Molecular mechanisms of plant response to ionising radiation. Exploration of the glucosinolate role in the anti-oxidative response

    International Nuclear Information System (INIS)

    Gicquel, M.

    2012-01-01

    Terrestrial organisms are exposed to low doses of ionising radiation from natural or anthropogenic sources. The major effects of the radiations are due to DNA deterioration and water radiolysis which generates an oxidative stress by free radical production. Plants constitute good models to study the effects of ionising radiations and the search of antioxidant molecules because of their important secondary metabolism. Thus this thesis, funded by the Brittany region, characterized the physiological and molecular response of the model plant Arabidopsis thaliana to low (10 Gy) and moderate (40 Gy) doses of ionising radiation, and was therefore interested in glucosinolates, characteristic compounds of the Brassicaceae family. The global proteomic and transcriptomic studies carried out on this model revealed (1) a common response for both doses dealing with the activation of DNA repair mechanisms, cell cycle regulation and protection of cellular structures; (2) an adjustment of the energetic metabolism and an activation of secondary compounds biosynthesis (i.e. glucosinolates and flavonoids) after the 10 Gy dose; (3) an induction of enzymatic control of ROS, the regulation of cellular components recycling and of programmed cell death after the 40 Gy dose. The potential anti-oxidative role of glucosinolates was then explored. The in vitro anti-oxidative power of some glucosinolates and their derivative products were demonstrated. Their modulating effects against irradiation-induced damages were then tested in vivo by simple experimental approaches. The importance of the glucosinolate level to give a positive or negative effect was demonstrated. (author)

  11. Ionisation differential cross section measurements for N2 at low incident energy in coplanar and non-coplanar geometries

    International Nuclear Information System (INIS)

    Sakaamini, Ahmad; Murray, Andrew James; Amami, Sadek; Madison, Don; Ning, Chuangang

    2016-01-01

    Ionisation triple differential cross sections have been determined experimentally and theoretically for the neutral molecule N 2 over a range of geometries from coplanar to the perpendicular plane. Data were obtained at incident electron energies ∼10 and ∼20 eV above the ionisation potential of the 3 σ g , 1 π u and 2 σ g states, using both equal and non-equal outgoing electron energies. The data were taken with the incident electron beam in the scattering plane ( ψ = 0°), at 45° to this plane and orthogonal to the plane ( ψ = 90°). The set of nine measured differential cross sections at a given energy were then inter-normalised to each other. The data are compared to new calculations using various distorted wave methods, and differences between theory and experiment are discussed. (paper)

  12. The gas-phase on-line production of vanadium oxytrihalides, VOX3 and their identification by infrared spectroscopy

    International Nuclear Information System (INIS)

    Zidan, M. D.; Allaf, A. W.

    2001-01-01

    A new route has been devised, leading to the production of VOX 3 molecules where X=F, Br and I by an on-line process using vanadium oxytrichloride, VOCl 3 as a starting compound passed over the following heated salts NaF, KBr and KI at 375, 700 and 550 centigrade, respectively. The products have been characterized by the IR spectra of their vapors. the low resolution gas phase on-line Fourier transform infrared spectra reported for the first time show strong bands with PQR type structure, centered at 1058, 1035, 1030 and 1025 cm -1 to the υ 1 (a 1 ), the O=V stretching fundamental mode of VOF 3 , VOCl 3 , VOBr 3 and VOI 3 , respectively. (Author)

  13. On the derivation of the ionisation threshold law

    International Nuclear Information System (INIS)

    Peterkop, R.

    1983-01-01

    The different procedures for derivation of the electron-atom ionisation threshold law have been analysed and the reasons for discrepancies in the results are pointed out. It is shown that if the wavefunction has a linear node at equal electron distances (r 1 =r 2 ), then the threshold law for the total cross section has the form σ approx. Esup(3m), where σ approx. Esup(m) is the Wannier law. The distribution of energy between escaping electrons is non-uniform and has a parabolic node at equal energies (epsilon 1 = epsilon 2 ). The linear node at opposite directions of electrons (theta = π) does not change the Wannier law but leads to a parabolic node in angular distribution at theta = π. The existence of both nodes leads to the threshold law σ approx. Esup(3m) and to parabolic nodes in energy and angular distributions. (author)

  14. Studies of Non-Targeted Effects of Ionising Radiation

    International Nuclear Information System (INIS)

    Oleg V Belyakov; Heli Mononen; Marjo Peraelae

    2006-01-01

    The discovery of ionising radiation induced non-targeted effects is important for understanding the dose-response mechanisms relevant to low dose irradiation in vivo. One important question is whether the non-targeted effects relates to a protective mechanism or whether, conversely, it amplifies the number of cells damaged by the isolated radiation tracks of low dose exposures leading to an increased risk of carcinogenesis. One theory supported by the experimental data obtained during this project is that the main functions of the non-targeted effects are to decrease the risk of transformation in a multicellular organism exposed to radiation. Differences in the gene expression profiles, temporal and spatial patterns of key proteins expressed in directly irradiated and bystander cells may determine how the cells ultimately respond to low doses of radiation. Such a mechanism of co-operative response would make the tissue system much more robust. (N.C.)

  15. Studies of Non-Targeted Effects of Ionising Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Oleg V Belyakov; Heli Mononen; Marjo Peraelae [STUK - Radiation and Nuclear Safety Authority, Helsinki (Finland)

    2006-07-01

    The discovery of ionising radiation induced non-targeted effects is important for understanding the dose-response mechanisms relevant to low dose irradiation in vivo. One important question is whether the non-targeted effects relates to a protective mechanism or whether, conversely, it amplifies the number of cells damaged by the isolated radiation tracks of low dose exposures leading to an increased risk of carcinogenesis. One theory supported by the experimental data obtained during this project is that the main functions of the non-targeted effects are to decrease the risk of transformation in a multicellular organism exposed to radiation. Differences in the gene expression profiles, temporal and spatial patterns of key proteins expressed in directly irradiated and bystander cells may determine how the cells ultimately respond to low doses of radiation. Such a mechanism of co-operative response would make the tissue system much more robust. (N.C.)

  16. Activity standardisation of 18F and ionisation chamber calibration for nuclear medicine

    International Nuclear Information System (INIS)

    Schrader, H.; Klein, R.; Kossert, K.

    2007-01-01

    Primary activity standardisations were performed on solutions of 18 F using 4πβ-γ coincidence counting and liquid scintillation counting (LSC) according to the CIEMAT/NIST method. A β + -emission probability of 96.86% was used for both methods. The various standardised 18 F solutions were measured in ionisation chambers of the Physikalisch-Technische Bundesanstalt (PTB) and compared by determining radionuclide calibration factors. Already in 2001 an 18 F solution had been standardised at the PTB and compared with the results of nine national metrology institutes (NMIs), using the ISOCAL IV secondary radionuclide calibrators of the National Physical Laboratory (NPL) as transfer instruments and a 68 Ge check source solution. These results were linked to the International Reference System (SIR) at the Bureau International des Poids et Mesures (BIPM) by aliquots of solutions sent by the Laboratoire National Henri Becquerel (BNM-LNHB) and the NPL. Further on, in 2005, PTB sent an aliquot of an 18 F solution to the SIR for ionisation chamber measurements. A value of the equivalent activity was determined and included in the key comparison database (KCDB). The recent PTB value of the equivalent activity of the SIR is in good agreement with the key comparison reference value determined from five NMIs. These results confirm that the standardisation of 18 F solutions can be achieved with the accuracy required for use in nuclear medicine and, in particular, for applications in positron emission tomography (PET)

  17. Impact ionisation rate calculations in wide band gap semiconductors

    International Nuclear Information System (INIS)

    Harrison, D.

    1998-09-01

    Calculations of band-to-band impact ionisation rates performed in the semi-classical Fermi's Golden Rule approximation are presented here for the semiconductors GaAs, In 0.53 Ga 0.47 As and Si 0.5 Ge 0.5 at 300K. The crystal band structure is calculated using the empirical pseudopotential method. To increase the speed with which band structure data at arbitrary k-vectors can be obtained, an interpolation scheme has been developed. Energies are quadratically interpolated on adapted meshes designed to ensure accuracy is uniform throughout the Brillouin zone, and pseudowavefunctions are quadratically interpolated on a regular mesh. Matrix elements are calculated from the pseudowavefunctions, and include the terms commonly neglected in calculations for narrow band gap materials and an isotropic approximation to the full wavevector and frequency dependent dielectric function. The numerical integration of the rate over all distinct energy and wavevector conserving transitions is performed using two different algorithms. Results from each are compared and found to be in good agreement, indicating that the algorithms are reliable. The rates for electrons and holes in each material are calculated as functions of the k-vector of the impacting carriers, and found to be highly anisotropic. Average rates for impacting carriers at a given energy are calculated and fitted to Keldysh-type expressions with higher than quadratic dependence of the rate on energy above threshold being obtained in all cases. The average rates calculated here are compared to results obtained by other workers, with reasonable agreement being obtained for GaAs, and poorer agreement obtained for InGaAs and SiGe. Possible reasons for the disagreement are investigated. The impact ionisation thresholds are examined and k-space and energy distributions of generated carriers are determined. The role of threshold anisotropy, variation in the matrix elements and the shape of the bands in determining

  18. Line lessons: Enbridge's Northern Line provides valuable information

    Energy Technology Data Exchange (ETDEWEB)

    Ross, E.

    2000-02-01

    Experiences gained from the 14-year old Norman Wells crude oil pipeline in the Northwest Territories may provide operators with valuable insights in natural gas pipeline developments in northern Canada. The Norman Wells line is the first and only long-distance pipeline in North America buried in permafrost and has proven to be a veritable laboratory on pipeline behaviour in extremely cold climates which also happen to be discontinuous at the same time. The line was built by Enbridge with a 'limit state' design, i e. it was built to move within the permafrost within certain limits, the amount of movement depending upon the area in which the line was built. This technology, which is still cutting edge, allows the pipeline to react to the freeze-thaw cycle without being affected by the heaving and resettling. The knowledge gained from the Norman Wells Line has come in very useful in the more recent AltaGas Services project transporting natural gas from a nearby well into the the town of Inuvik. Enbridge also contributed to the development of various pipeline inspection tools such as the 'Geopig' which travels within the pipeline and can pinpoint the location of problems practically within a matter of inches, and the 'Rolligon' an amphibious vehicle with five-foot diameter rubber tires that displaces only two pounds per square inch, leaving barely a track as it travels along the right-of-way during times other than winter.

  19. A gas proportional scintillation counter for use in large area detector systems without photomultipliers

    International Nuclear Information System (INIS)

    Baruch, J.E.F.; Brooke, G.; Kellermann, E.W.; Bateman, J.E.; Connolly, J.F.

    1978-03-01

    The properties of a prototype gas proportional scintillation detector, for use in large numbers, are examined. The detector is designed to focus a light signal, which is proportional to ionisation loss, into a fibre optic lightguide. It is shown that a single charged particle traversing the detector produces enough light out of the lightguide to be seen by a TV camera. Problems of lifetime and large scale detector production are discussed. Properties of saturation, linearity, position sensitivity, and operating limits are examined. It is shown that an array of gas proportional scintillation detectors when used with fibre optic lightguides and TV camera readout could offer significant improvements in cost per area and reliability over a scintillator plus photomultiplier or a wire proportional chamber array. (author)

  20. Simulation Of The Secondary Cooling System Failed For One Line Mode Of RSG-GAS

    International Nuclear Information System (INIS)

    Dibyo, Sukmanto; Susyadi; Sembiring, Tagor M; Isnaeni, Darwis

    2003-01-01

    Recently, an assessment of 15 MW power reactor RSG-GAS operated using one line cooling mode is under carried out, in which is in the same manner as BA TAN policy. At the power above mentioned, requirement for the research as well as isotop production has been fulfilled. To obtain the transient condition of 1 line-cooling mode, the simulation using RELAP5.MOD3.2 code was carried out. The simulation parameters interesting known are the inlet of primary coolant temperature after failed the secondary cooling system. At the first, reactor is operated at 15 MW steady state condition using 1 line-cooling mode. Primary coolant flow rate of 430 kg/s and secondary of 550 kg/s respectively. After that the decreasing is occurred due to stop of secondary cooling pump. Therefore the primary cooling inlet temperature to the core increase cause scram reactor by inserted control rod. During the transient occur, the characteristic of primary cooling temperature pattern change were obtained. The simulation result shows that the temperature increase (ΔT) temperature to the reactor is 5,1 o C at the second of 85.5. Here is lower than ΔT for the two cooling mode of 10 o C. That temperature characteristic still tolerable against acceptable safety margin to the flow instability

  1. RF System for the MICE Demonstration of Ionisation Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Ronald, K.; et al.

    2017-04-01

    Muon accelerators offer an attractive option for a range of future particle physics experiments. They can enable high energy (TeV+) high energy lepton colliders whilst mitigating the difficulty of synchrotron losses, and can provide intense beams of neutrinos for fundamental physics experiments investigating the physics of flavor. The method of production of muon beams results in high beam emittance which must be reduced for efficient acceleration. Conventional emittance control schemes take too long, given the very short (2.2 microsecond) rest lifetime of the muon. Ionisation cooling offers a much faster approach to reducing particle emittance, and the international MICE collaboration aims to demonstrate this technique for the first time. This paper will present the MICE RF system and its role in the context of the overall experiment.

  2. Influence of SNP Polymorphisms in DNA Repair Genes on the Level of Persistent Damage in Human Lymphocytes After Exposure to 2 Gy of Ionising Radiation

    International Nuclear Information System (INIS)

    Milic, M.; Rozgaj, R.; Kasuba, V.; Kubelka, D.; Angelini, S.; Hrelia, P.

    2011-01-01

    Variation in cell response to ionising radiation could be result of changes in gene expression and/or polymorphisms of DNA repair genes. The aim of the study was to estimate the DNA damage level in human lymphocytes after exposure to 2 Gy of ionising radiation. Medical workers occupationally exposed to low doses of ionising radiation (N = 20) and matched controls (N 20) were genotyped for polymorphic hOGG1, XRCC1, APE1, XPD10, XPD23, XRCC3, PARP1 and MGMT genes. Micronucleus (MN) test was used for the estimation of DNA damage before and after radiation. Incidence of MN in irradiated samples positively correlated with age and negatively with polymorphic variants of XPD23. Significant difference was observed between irradiated homozygotes (HO) and heterozygotes (HE). HO and HE APE1 differed in MN before exposure. HO and polymorphic variants of XPD10 differed in MN after exposure. Gender showed different MN in the exposed group after exposure. Age correlated positively with MN after exposure, working probation and received dose. Multiple regression analysis revealed connection between polymorphic variants of APE1 and XRCC3 with MN before exposure. These results confirm the value of micronucleus assay in DNA damage estimation and suggest possible use of polymorphic genes in monitoring of individuals professionaly exposed to ionising radiation. (author)

  3. A front-end ASIC for ionising radiation monitoring with femto-amp capabilities

    International Nuclear Information System (INIS)

    Voulgari, E.; Noy, M.; Anghinolfi, F.; Perrin, D.; Krummenacher, F.; Kayal, M.

    2016-01-01

    An ultra-low leakage current Application Specific Integrated Circuit (ASIC) called Utopia (Ultralow Picoammeter) has been designed and fabricated in AMS 0.35 μm CMOS, in order to be used as the front-end for ionising radiation monitoring at CERN. It is based on the topology of a Current to Frequency Converter (CFC) through charge balancing and demonstrates a wide dynamic range of 8.5 decades without range changing. Due to a design aimed at minimising input leakage currents, input currents as low as 01 fA can be measured

  4. Transformation kinetics of chlorinated ethenes by Methylosinus trichosporium OB3b and detection of unstable epoxides by on-line gas chromatography

    NARCIS (Netherlands)

    van Hylckama Vlieg, Johan. E.T.; Koning, Wim de; Janssen, Dick B.

    A rapid and accurate method for the determination of transformation kinetics of volatile organic substrates was developed. Concentrations were monitored by on-line gas chromatographic analysis of the headspace of well-mixed incubation mixtures. With this method, the kinetics of transformation of a

  5. Single-particle and collective properties around closed shells probed by in-source laser spectroscopy

    CERN Document Server

    Cocolios, Thomas Elias; Van Duppen, P

    2010-01-01

    Resonant laser ionisation is a very versatile tool in nuclear physics, used for the production of clean radioactive ion beams as well as for the study of ground-state and isomer properties. In this Ph.D. work, many aspects of resonant laser ionisation are investigated, from improving the performance of laser ion sources at ISOL facilities to the measurement of magnetic dipole moments and charge radii. The LISOL gas catcher ion source relies on resonant laser ionisation for increased efficiency and selectivity. Using a $^{252}$Cf fission source, the element dependence of the non-resonant contribution to the ion beam has been investigated. The efficiency of extraction for a non-laser-ionised element ranges from 0.03% for krypton to 74% for ceasium. A relationship with the ionisation potential is proposed, although a few elements like rubidium and cerium do not verify this relationship. In order to suppress those non-resonantly-ionised elements, two new approaches are proposed. First, the dual-chamber gas catche...

  6. 75 FR 39680 - Houston Pipe Line Company LP, Worsham-Steed Gas Storage, L.P., Energy Transfer Fuel, LP, Mid...

    Science.gov (United States)

    2010-07-12

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-44-000; Docket No. PR10-46-000; Docket No. PR10-48- 000; Docket No. PR10-49-000; Docket No. PR10-50-000] Houston Pipe Line Company LP, Worsham-Steed Gas Storage, L.P., Energy Transfer Fuel, LP, Mid Continent Market Center, L.L.C...

  7. Metabolite signal identification in accurate mass metabolomics data with MZedDB, an interactive m/z annotation tool utilising predicted ionisation behaviour 'rules'

    Directory of Open Access Journals (Sweden)

    Snowdon Stuart

    2009-07-01

    Full Text Available Abstract Background Metabolomics experiments using Mass Spectrometry (MS technology measure the mass to charge ratio (m/z and intensity of ionised molecules in crude extracts of complex biological samples to generate high dimensional metabolite 'fingerprint' or metabolite 'profile' data. High resolution MS instruments perform routinely with a mass accuracy of Results Metabolite 'structures' harvested from publicly accessible databases were converted into a common format to generate a comprehensive archive in MZedDB. 'Rules' were derived from chemical information that allowed MZedDB to generate a list of adducts and neutral loss fragments putatively able to form for each structure and calculate, on the fly, the exact molecular weight of every potential ionisation product to provide targets for annotation searches based on accurate mass. We demonstrate that data matrices representing populations of ionisation products generated from different biological matrices contain a large proportion (sometimes > 50% of molecular isotopes, salt adducts and neutral loss fragments. Correlation analysis of ESI-MS data features confirmed the predicted relationships of m/z signals. An integrated isotope enumerator in MZedDB allowed verification of exact isotopic pattern distributions to corroborate experimental data. Conclusion We conclude that although ultra-high accurate mass instruments provide major insight into the chemical diversity of biological extracts, the facile annotation of a large proportion of signals is not possible by simple, automated query of current databases using computed molecular formulae. Parameterising MZedDB to take into account predicted ionisation behaviour and the biological source of any sample improves greatly both the frequency and accuracy of potential annotation 'hits' in ESI-MS data.

  8. US gas line contract carriage on the rise

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This paper reports that the Interstate Natural Gas Association of America reports contract carriage moved 84% of the gas delivered to U.S. markets in 1991, up from 79% the previous year. Carriage for market transportation for distributors, end users, and marketers totaled 15.2 quadrillion BTU, a 13% increase from the 13.4 quads reported at the end of 1990. Ingaa the growth in carriage volumes has slowed. This year's 13% increase is lower than the 28% growth in carriage volumes from 1988 to 1989 and the 72% from 1986 to 1987. Total natural gas delivered to market was 18 quads in 1991, an increase of 5% from the 1990 level of 17.1 quads. Pipeline sales accounted for only 16% of the gas delivered to market in 1991. They dropped 0.8 quads, or 22%, from 1990 levels. Ingaa the while the market relies heavily on carriage throughout the year, reliance on carriage is somewhat heavier as has been the case since 1986 during the off peak season in April-September

  9. Measurement of the total ionisation intensity near the ground and separation of the various components; Mesure de l'intensite totale d'ionisation au voisinage du sol et separation de ses differentes composantes

    Energy Technology Data Exchange (ETDEWEB)

    Grevet, Ph [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1965-06-01

    The aim of this work is to measure the total amount of ion-pairs produced in the air per unit time and unit volume. It is possible, furthermore, by using continuous recording to study the variations in the ionisation due to {alpha}, {beta} and {gamma} radiation at a height of one metre. The apparatus which has been developed consists of two chambers of 120 litres: one, hermetically sealed detects the {gamma} component, the other with a circulation of the ambient air detects the {alpha} and {gamma}; it is thus possible by difference to evaluate the {alpha} component. The chambers and the associated electronic equipment have been designed for continuous operation in the open air. Another chamber without walls can be used for measuring directly the total ionisation intensity and from this an approximate calculation may be made of the {beta} component. A series of recordings has been made near Saclay where the natural radio-activity level is moderate, and in regions of low and high activity (near the sea and in the CEA's mining divisions). It has thus been possible to show the variation in the {gamma} component as a function of the geographic position of the measurement (from 3.7 to 6.3 l/cm{sup 3}.s), the very large variations of the {alpha} component at a given place with changing meteorological conditions (from 1.5 to 45 l/cm{sup 3}.s at Saclay for example) an the far smaller variations in the {beta} component. (author) [French] Le but de ce travail est de mesurer la quantite totale de paires d'ions produite dans l'air par unite de temps et de volume. Des enregistrements continus permettent, de plus, d'etudier les variations a 1 m du sol de cette ionisation due aux rayonnements {alpha}, {beta} et {gamma}. L'appareillage mis au point est forme de deux chambres de 120 litres: l'une hermetiquement fermee detecte la composante {gamma}; l'autre avec circulation de l'air ambiant detecte {alpha} + {gamma} ce qui permet d'evaluer par difference la composante {alpha}. Les

  10. A new mathematical formulation of the line-by-line method in case of weak line overlapping

    Science.gov (United States)

    Ishov, Alexander G.; Krymova, Natalie V.

    1994-01-01

    A rigorous mathematical proof is presented for multiline representation on the equivalent width of a molecular band which consists in the general case of n overlapping spectral lines. The multiline representation includes a principal term and terms of minor significance. The principal term is the equivalent width of the molecular band consisting of the same n nonoverlapping spectral lines. The terms of minor significance take into consideration the overlapping of two, three and more spectral lines. They are small in case of the weak overlapping of spectral lines in the molecular band. The multiline representation can be easily generalized for optically inhomogeneous gas media and holds true for combinations of molecular bands. If the band lines overlap weakly the standard formulation of line-by-line method becomes too labor-consuming. In this case the multiline representation permits line-by-line calculations to be performed more effectively. Other useful properties of the multiline representation are pointed out.

  11. Isotope Dilution - Thermal Ionisation Mass Spectrometric Analysis for Tin in a Fly Ash Material

    International Nuclear Information System (INIS)

    Hernandez, C.; Fernandez, M.; Quejido, A. L.

    2006-01-01

    Isotope dilution-thermal ionisation mass spectrometry (ID-TIMS) analysis has been applied to the determination of tin in a fly ash sample supplied by the EC Joint Research Centre (Ispra, Italy). The proposed procedure includes the silica gel/phosphoric acid technique for tin thermal ionisation activation and a strict heating protocol for isotope ratio measurements. Instrumental mass discrimination factor has been previously determined measuring a natural tin standard solution. Spike solutions has been prepared from 112Sn-enriched metal and quantified by reverse isotope dilution analysis. Two sample aliquots were spiked and tin was extracted with 4,5 M HCI during 25 min ultrasound esposure time. Due to the complex matrix of this fly ash material, a two-steps purification stage using ion-exchange chromatography was required prior TIMS analysis. Obtained results for the two sample-spike blends (10,10 + - 0,55 y 10,50 + - 0,64 imolg-1) are comprarable, both value and uncertainty. Also a good reproducibility is observed between measurements. The proposed ID-TIMS procedure, as a primary method and due to the lack of fly ash reference material certified for tin content, can be used to validate more routine methodologies applied to tin determination in this kind of materials. (Author) 75 refs

  12. The electrical charging of inactive aerosols in high ionised atmosphere, the electrical charging of artificial beta radioactive aerosols; Le processus de charge electrique: des aerosols non radioactifs en milieu fortement ionise, des aerosols radioactifs artificiels emetteurs beta

    Energy Technology Data Exchange (ETDEWEB)

    Gensdarmes, F

    2000-07-01

    The electrical properties of aerosols greatly influence their transport and deposition in a containment. In a bipolar ionic atmosphere, a neutral electric charge on aerosols is commonly assumed. However, many studies report a different charge distribution in some situations, like highly ionised atmosphere or in the case of radioactive aerosols. Such situations could arise from a hypothetical accident in a nuclear power plant. Within the framework of safety studies which are carried out at IPSN, our aims were the study of electrical properties of aerosols in highly ionised atmosphere, and the study of artificial radioactive aerosols, in order to suggest experimental validation of available theories. For this purpose, we designed an experimental device that allows us to measure non-radioactive aerosol charge distribution under high gamma irradiation, up to 10{sup 4} Gy/h. With our experimental device we also studied the properties of small ions in the medium. Our results show a variation of the charge distribution in highly ionised atmosphere. The charge increases with the dose of gamma ray. We have related this variation with the one of the small ions in the gases, according to theoretical prediction. However, the model overestimates slightly our experimental results. In the case of the radioactive aerosols, we have designed an original experimental device, which allows us to study the charge distribution of a {sup 137}Cs aerosol. Our results show that the electric charging of such aerosols is strongly dependent on evolution parameters in a containment. So, our results underline a great enhancement of self-charging of particles which are sampled in a confined medium. Our results are qualitatively in agreement with the theoretical model; nevertheless the latter underestimates appreciably the self-charging, owing to the fact that wall effects are not taken into account. (author)

  13. Fluorescence in situ hybridisation in chromosome aberration detection in subjects occupationally exposed to ionising radiation

    International Nuclear Information System (INIS)

    Zeljezic, D.; Garaj-Vrhovac, V.

    2005-01-01

    For more than two decades, chromosomal aberration analysis has been used to detect structural chromosomal aberrations as sensitive biodosimeters of occupational exposure to ionising radiation. Its use is also recommended by the World Health Organisation. Changes in chromosome structure detected by that method are considered to be early biomarkers of a possible malignant disease. Aberrations detected by the method are unstable and can be found in the lymphocytes of irradiated personnel only within a limited time after exposure. To detect stable chromosomal aberrations, which persist after exposure, multicolour fluorescent in situ hybridisation has to be used. Using DNA probes labelled with different fluorochromes, it dyes each pair of chromosomes with different colour. Due to the dynamic of unstable aberration formation, chromosomal aberration analysis is more suitable in genome damage assessment of recent exposures. On the other hand, fluorescence in situ hybridisation gives the information on chromosome instability caused by long-term occupational exposure to ionising radiation. Considering the high costs of fluorescence in situ hybridisation and the uncertainty of the result, it should be used in biodosimetry only when it is absolutely necessary.(author)

  14. Modelling the propagation of effects of chronic exposure to ionising radiation from individuals to populations

    Energy Technology Data Exchange (ETDEWEB)

    Alonzo, F. [Laboratory of Environmental Modelling, DEI/SECRE/LME, Institute of Radioprotection and Nuclear Safety (IRSN), Cadarache, Building 159, BP3, 13115 St-Paul-lez-Durance Cedex (France); Laboratory of Radioecology and Ecotoxicology, DEI/SECRE/LRE, Institute of Radioprotection and Nuclear Safety (IRSN), Cadarache Building 186, BP3, 13115 St-Paul-lez-Durance Cedex (France)], E-mail: frederic.alonzo@irsn.fr; Hertel-Aas, T. [Department of Plant and Environmental Sciences, P.O. Box 5003, Norwegian University of Life Sciences, 1432 Aas (Norway); Gilek, M. [School of Life Sciences, Soedertoern University College, 14189 Huddinge (Sweden); Gilbin, R. [Laboratory of Radioecology and Ecotoxicology, DEI/SECRE/LRE, Institute of Radioprotection and Nuclear Safety (IRSN), Cadarache Building 186, BP3, 13115 St-Paul-lez-Durance Cedex (France); Oughton, D.H. [Department of Plant and Environmental Sciences, P.O. Box 5003, Norwegian University of Life Sciences, 1432 Aas (Norway); Garnier-Laplace, J. [Laboratory of Radioecology and Ecotoxicology, DEI/SECRE/LRE, Institute of Radioprotection and Nuclear Safety (IRSN), Cadarache Building 186, BP3, 13115 St-Paul-lez-Durance Cedex (France)

    2008-09-15

    This study evaluated the potential effect of ionising radiation on population growth using simple population models and parameter values derived from chronic exposure experiments in two invertebrate species with contrasting life-history strategies. In the earthworm Eisenia fetida, models predicted increasing delay in population growth with increasing gamma dose rate (up to 0.6 generation times at 11 mGy h{sup -1}). Population extinction was predicted at 43 mGy h{sup -1}. In the microcrustacean Daphnia magna, models predicted increasing delay in population growth with increasing alpha dose rate (up to 0.8 generation times at 15.0 mGy h{sup -1}), only after two successive generations were exposed. The study examined population effects of changes in different individual endpoints (including survival, number of offspring produced and time to first reproduction). Models showed that the two species did not respond equally to equivalent levels of change, the fast growing daphnids being more susceptible to reduction in fecundity or delay in reproduction than the slow growing earthworms. This suggested that susceptibility of a population to ionising radiation cannot be considered independent of the species' life history.

  15. Calculated ionisation potentials to determine the oxidation of vanillin precursors by lignin peroxidase.

    OpenAIRE

    Have, ten, R.; Rietjens, I.M.C.M.; Hartmans, S.; Swarts, H.J.; Field, J.A.

    1998-01-01

    In view of the biocatalytic production of vanillin, this research focused on the lignin peroxidase (LiP) catalysed oxidation of naturally occurring phenolic derivatives: O-methyl ethers, O-acetyl esters, and O-glucosyl ethers. The ionisation potential (IP) of a series of model compounds was calculated and compared to their experimental conversion by LiP, defining a relative IP threshold of approximately 9.0 eV. Based on this threshold value only the O-acetyl esters and glucosides of isoeugeno...

  16. High-resolution measurement, line identification, and spectral modeling of the Kβ spectrum of heliumlike argon emitted by a laser-produced plasma using a gas-puff target

    International Nuclear Information System (INIS)

    Skobelev, I.Y.; Faenov, A.Y.; Dyakin, V.M.; Fiedorowicz, H.; Bartnik, A.; Szczurek, M.; Beiersdorfer, P.; Nilsen, J.; Osterheld, A.L.

    1997-01-01

    We present an analysis of the spectrum of satellite transitions to the He-β line in ArXVII. High-resolution measurements of the spectra from laser-heated Ar-gas-puff targets are made with spectral resolution of 10000 and spatial resolution of better than 50 μm. These are compared with tokamak measurements. Several different lines are identified in the spectra and the spectral analysis is used to determine the plasma parameters in the gas-puff laser-produced plasma. The data complement those from tokamak measurements to provide more complete information on the satellite spectra. copyright 1997 The American Physical Society

  17. Accuracy evaluation of the prescribed calibration factors for ionisation chambers belonging to radiotherapy centres

    International Nuclear Information System (INIS)

    Mohd Taufik Dolah; Supian Samat; Taiman Kadni

    1999-01-01

    Air kerma and exposure calibration factors of 14 ionisation chambers belonging to ten local radiotherapy centres have been determined by SSDL in the recent last ten month (1/10/1998 - 31/7/1999). The results obtained were compared either with previous SSDL results, or the chambers certificate values. The range of the percentage deviations obtained was -1.70% to 1.18%, which lies between the IAEA accepted value of range ±3.5%. (author)

  18. Semiempirical confrontations between theory and experiment in highly ionised complex atoms

    International Nuclear Information System (INIS)

    Curtis, L.J.

    1989-01-01

    Highly ionised complex atoms, which have many electrons stripped away but many electrons still remaining, are presently a subject of vigorous experimental study. The high precision experimentally attainable for these systems suggests their use in the investigation of higher order theoretical processes, and the specification of these interactions is essential to the development of reliable predictive methods. It is shown that parametric reductions which combine ab initio theoretical calculations with experimental observations can yield predictions of much higher precision than could be obtained from either source separately. These formulations also reveal subtle regularities in the measured data that are not exhibited by the corresponding computations, which suggest possible calculational improvements. (orig.)

  19. Characterisation of the muon beams for the Muon Ionisation Cooling Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Adams, D.; Barclay, P.; Bayliss, V.; Bradshaw, T.W.; Courthold, M.; Francis, V.; Fry, L.; Hayler, T.; Hills, M.; Lintern, A.; Macwaters, C.; Nichols, A.; Preece, R.; Ricciardi, S.; Rogers, C.; Stanley, T.; Tarrant, J.; Watson, S.; Wilson, A. [Harwell Oxford, STFC Rutherford Appleton Laboratory, Didcot (United Kingdom); Adey, D.; Back, J.; Boyd, S.; Harrison, P.; Pidcott, C.; Taylor, I. [University of Warwick, Department of Physics, Coventry (United Kingdom); Alekou, A.; Apollonio, M.; Barber, G.; Colling, D.; Dobbs, A.; Dornan, P.; Fayer, S.; Fish, A.; Hunt, C.; Leaver, J.; Long, K.; Martyniak, J.; Middleton, S.; Pasternak, J.; Richards, A.; Santos, E.; Savidge, T.; Takahashi, M. [Imperial College London, Department of Physics, Blackett Laboratory, London (United Kingdom); Asfandiyarov, R.; Blondel, A.; Graulich, J.S.; Karadzhov, Y.; Verguilov, V.; Wisting, H. [Universite de Geneve, DPNC, Section de Physique, Geneva (Switzerland); De Bari, A.; Cecchet, G. [Sezione INFN Pavia (Italy); Dipartimento di Fisica Nucleare e Teorica, Pavia (Italy); Bayes, R.; Forrest, D.; Nugent, J.C.; Soler, F.J.P.; Walaron, K. [The University of Glasgow, School of Physics and Astronomy, Glasgow (United Kingdom); Bertoni, R.; Bonesini, M.; Lucchini, G. [Sezione INFN Milano Bicocca (Italy); Dipartimento di Fisica G. Occhialini, Milano (Italy); Blackmore, V.J.; Carlisle, T.; Cobb, J.H.; Lau, W.; Rayner, M.A.; Tunnell, C.D. [University of Oxford, Department of Physics, Oxford (United Kingdom); Blot, S.; Kim, Y.K. [University of Chicago, Enrico Fermi Institute, Chicago, IL (United States); Bogomilov, M.; Kolev, D.; Rusinov, I.; Tsenov, R.; Vankova, G. [St. Kliment Ohridski University of Sofia, Department of Atomic Physics, Sofia (Bulgaria); Booth, C.N.; Hodgson, P.; Nicholson, R.; Overton, E.; Robinson, M.; Smith, P.J. [University of Sheffield, Department of Physics and Astronomy, Sheffield (United Kingdom); Bowring, D.; DeMello, A.; Gourlay, S.; Li, D.; Prestemon, S.; Virostek, S.P.; Zisman, M.S. [Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Bravar, U. [University of New Hampshire, Durham, NH (United States); Bross, A.D.; Fitzpatrick, T.; Leonova, M.; Moretti, A.; Neuffer, D.; Popovic, M.; Rubinov, P.; Rucinski, R. [Fermilab, Batavia, IL (United States); Capponi, M.; Iaciofano, A.; Orestano, D.; Pastore, F.; Tortora, L. [Sezione INFN Roma Tre e Dipartimento di Fisica, Roma (Italy); Charnley, G.; Collomb, N.; Gallagher, A.; Grant, A.; Griffiths, S.; Hartnett, T.; Martlew, B.; Moss, A.; Muir, A.; Mullacrane, I.; Owens, P.; White, C. [STFC Daresbury Laboratory, Cheshire (United Kingdom); Coney, L.; Fletcher, R.; Hanson, G.G.; Heidt, C. [University of California, Riverside, CA (United States); Cooke, P.; Gamet, R. [University of Liverpool, Department of Physics, Liverpool (United Kingdom); Cremaldi, L.M.; Hart, T.L.; Luo, T.; Sanders, D.A.; Summers, D.J. [University of Mississippi, Oxford, MS (United States); Dick, A.J.; Ronald, K.; Whyte, C.G. [University of Strathclyde, Department of Physics, Glasgow (United Kingdom); Filthaut, F. [NIKHEF, Amsterdam (Netherlands); Freemire, B.; Hanlet, P.; Kafka, G.; Kaplan, D.M.; Rajaram, D.; Snopok, P.; Torun, Y. [Illinois Institute of Technology, Chicago, IL (United States); Hansen, O.M.; Ramberger, S.; Vretenar, M. [CERN, Geneva (Switzerland); Ishimoto, S. [Institute of Particle and Nuclear Studies, High Energy Accelerator Research Organization (KEK), Tsukuba, Ibaraki (Japan); Kuno, Y.; Sakamoto, H. [Osaka University, Graduate School of Science, Department of Physics, Toyonaka, Osaka (Japan); Kyberd, P.; Littlefield, M.; Nebrensky, J.J. [Brunel University, Uxbridge (United Kingdom); Onel, Y. [University of Iowa, Department of Physics and Astronomy, Iowa City, IA (United States); Palladino, V. [Universita Federico II, Sezione INFN Napoli (Italy); Dipartimento di Fisica, Napoli (Italy); Palmer, R.B. [Brookhaven National Laboratory, Upton, NY (US); Roberts, T.J. [Muons, Inc., Batavia, IL (US); Collaboration: The MICE Collaboration

    2013-10-15

    A novel single-particle technique to measure emittance has been developed and used to characterise seventeen different muon beams for the Muon Ionisation Cooling Experiment (MICE). The muon beams, whose mean momenta vary from 171 to 281 MeV/c, have emittances of approximately 1.2-2.3 {pi} mm-rad horizontally and 0.6-1.0 {pi} mm-rad vertically, a horizontal dispersion of 90-190 mm and momentum spreads of about 25 MeV/c. There is reasonable agreement between the measured parameters of the beams and the results of simulations. The beams are found to meet the requirements of MICE. (orig.)

  20. Characterisation of the muon beams for the Muon Ionisation Cooling Experiment

    International Nuclear Information System (INIS)

    Adams, D.; Barclay, P.; Bayliss, V.; Bradshaw, T.W.; Courthold, M.; Francis, V.; Fry, L.; Hayler, T.; Hills, M.; Lintern, A.; Macwaters, C.; Nichols, A.; Preece, R.; Ricciardi, S.; Rogers, C.; Stanley, T.; Tarrant, J.; Watson, S.; Wilson, A.; Adey, D.; Back, J.; Boyd, S.; Harrison, P.; Pidcott, C.; Taylor, I.; Alekou, A.; Apollonio, M.; Barber, G.; Colling, D.; Dobbs, A.; Dornan, P.; Fayer, S.; Fish, A.; Hunt, C.; Leaver, J.; Long, K.; Martyniak, J.; Middleton, S.; Pasternak, J.; Richards, A.; Santos, E.; Savidge, T.; Takahashi, M.; Asfandiyarov, R.; Blondel, A.; Graulich, J.S.; Karadzhov, Y.; Verguilov, V.; Wisting, H.; De Bari, A.; Cecchet, G.; Bayes, R.; Forrest, D.; Nugent, J.C.; Soler, F.J.P.; Walaron, K.; Bertoni, R.; Bonesini, M.; Lucchini, G.; Blackmore, V.J.; Carlisle, T.; Cobb, J.H.; Lau, W.; Rayner, M.A.; Tunnell, C.D.; Blot, S.; Kim, Y.K.; Bogomilov, M.; Kolev, D.; Rusinov, I.; Tsenov, R.; Vankova, G.; Booth, C.N.; Hodgson, P.; Nicholson, R.; Overton, E.; Robinson, M.; Smith, P.J.; Bowring, D.; DeMello, A.; Gourlay, S.; Li, D.; Prestemon, S.; Virostek, S.P.; Zisman, M.S.; Bravar, U.; Bross, A.D.; Fitzpatrick, T.; Leonova, M.; Moretti, A.; Neuffer, D.; Popovic, M.; Rubinov, P.; Rucinski, R.; Capponi, M.; Iaciofano, A.; Orestano, D.; Pastore, F.; Tortora, L.; Charnley, G.; Collomb, N.; Gallagher, A.; Grant, A.; Griffiths, S.; Hartnett, T.; Martlew, B.; Moss, A.; Muir, A.; Mullacrane, I.; Owens, P.; White, C.; Coney, L.; Fletcher, R.; Hanson, G.G.; Heidt, C.; Cooke, P.; Gamet, R.; Cremaldi, L.M.; Hart, T.L.; Luo, T.; Sanders, D.A.; Summers, D.J.; Dick, A.J.; Ronald, K.; Whyte, C.G.; Filthaut, F.; Freemire, B.; Hanlet, P.; Kafka, G.; Kaplan, D.M.; Rajaram, D.; Snopok, P.; Torun, Y.; Hansen, O.M.; Ramberger, S.; Vretenar, M.; Ishimoto, S.; Kuno, Y.; Sakamoto, H.; Kyberd, P.; Littlefield, M.; Nebrensky, J.J.; Onel, Y.; Palladino, V.; Palmer, R.B.; Roberts, T.J.

    2013-01-01

    A novel single-particle technique to measure emittance has been developed and used to characterise seventeen different muon beams for the Muon Ionisation Cooling Experiment (MICE). The muon beams, whose mean momenta vary from 171 to 281 MeV/c, have emittances of approximately 1.2-2.3 π mm-rad horizontally and 0.6-1.0 π mm-rad vertically, a horizontal dispersion of 90-190 mm and momentum spreads of about 25 MeV/c. There is reasonable agreement between the measured parameters of the beams and the results of simulations. The beams are found to meet the requirements of MICE. (orig.)

  1. Analysis Of The Heat Exchanger Capability At One Line Cooling System Operation Mode Of The RSG-GAS

    International Nuclear Information System (INIS)

    Dibyo, Sukmanto; Kuntoro, Iman

    2000-01-01

    In the frame of minimizing the operation lost of the RSG-GAS reactor, operation using one line cooling system at certain power range is being evaluated. Analysis the performance of cooling system for determining maximum power should be carried out. Analysis was carried out based on heat exchanger calculation using actual operation data. Constraints imposed to the analysis are that inlet cooling system to the reactor core shall be less than 42 o C. The result shows that by using one line of primary and secondary coolant flow of 1780 m exp. 3/hr and 2000 m 3 /hr and secondary coolant temperature from the cooling tower of 38 o C, the primary coolant to the core will be reach 42 o C if reactor operated at power of 16 MW

  2. The Assessment of DNA Damage in Poultry Spermatozoa after Exposure to Low Doses of Ionising Radiation

    International Nuclear Information System (INIS)

    Kasuba, V.; Milic, M.; Pejakovic Hlede, J.; Gottstein, Z.; Karadjole, M.; Miljanic, S.

    2013-01-01

    The existence of dose-related induction of DNA strand breaks in spermatozoa following in vitro exposure to ionising radiation represents sperm DNA integrity as an important parameter in the evaluation of semen functionality. Maintaining of normal sperm becomes even more important when it is known that DNA in semen samples is already fragmentated in certain amount in human and turkey semen and that it lacks DNA repair mechanisms making DNA damage irreversible. The aim of this paper was to provide an insight in the amount of DNA damage detected in chicken spermatozoa (5 cocks, 45 weeks old) of heavy line after radiation with doses of 0.3, 0.5, 1 and 2 Gy gamma radiation and to address the question of the potential ecological consequences of the damage that was measured with comet assay. Scored parameters included tail intensity, tail length and tail moment. Results showed sensitivity of comet assay technique that detected significant DNA damage even after exposure to 0.3 Gy, but also showed no dose-related responses after 0.5, 1 and 2 Gy. Distribution of damaged cells was widely spread for the higher doses, showing the influence of possible adaptive response, but for further conclusions, larger studies are needed to answer that question.(author)

  3. International Atomic Energy Agency Regional Workshop on Commercialisation of ionising energy treatment of food: proceedings

    International Nuclear Information System (INIS)

    Wills, P.; Toner, B.

    1985-01-01

    The global need to ensure adequate food supplies places a demand on new technologies and techniques to improve yields and preservation of food by eliminating or reducing bacterial degradation and infestation of raw or processed foods. The use of ionising radiation in food processing also has potential to alleviate certain food-borne diseases which cause serious threats to the health of people in many countries

  4. Theoretical methods for the calculation of the multiphoton ionisation cross-section of atoms and molecules

    International Nuclear Information System (INIS)

    Moccia, R.

    1991-01-01

    Some of the available theoretical methods to compute the two-photon ionisation cross-section of many-electron systems are reviewed. In particular the problems concerning the computation of (i) reliable approximations for the transition matrix elements and the excitation energies; and (ii) accurate results pertaining to the electronic continuum by the use of L 2 basis functions are considered. (author). 29 refs., 6 figs., 1 tab

  5. Simulation and measurements of the response of an air ionisation chamber exposed to a mixed high-energy radiation field

    International Nuclear Information System (INIS)

    Vincke, H.; Forkel-Wirth, D.; Perrin, D.; Theis, C.

    2005-01-01

    CERN's radiation protection group operates a network of simple and robust ionisation chambers that are installed inside CERN's accelerator tunnels. These ionisation chambers are used for the remote reading of ambient dose rate equivalents inside the machines during beam-off periods. This Radiation Protection Monitor for dose rates due to Induced Radioactivity ('PMI', trade name: PTW, Type 34031) is a non-confined air ionisation plastic chamber which is operated under atmospheric pressure. Besides its current field of operation it is planned to extend the use of this detector in the Large Hadron Collider to measure radiation under beam operation conditions to obtain an indication of the machine performance. Until now, studies of the PMI detector have been limited to the response to photons. In order to evaluate its response to other radiation components, this chamber type was tested at CERF, the high-energy reference field facility at CERN. Six PMI detectors were installed around a copper target being irradiated by a mixed hadron beam with a momentum of 120 GeV c -1 . Each of the chosen detector positions was defined by a different radiation field, varying in type and energy of the incident particles. For all positions, detailed measurements and FLUKA simulations of the detector response were performed. This paper presents the promising comparison between the measurements and simulations and analyses the influence of the different particle types on the resulting detector response. (authors)

  6. Testing of the effect of the entry beam tube windows of the silicon detectors of the ionisation radiation

    International Nuclear Information System (INIS)

    Kopestansky, J.; Tykva, R.; Stanek, S.

    1995-01-01

    This paper deals with testing of the entry beam tube windows of the silicon detectors of the ionisation radiation with surface barrier.The influence of the parameters of basic material and modified technologic preparation on the size and homogeneity of the windows was tested

  7. 3D Studies of Neutral and Ionised Gas and Stars in Seyfert and Inactive Galaxies

    NARCIS (Netherlands)

    Mundell, C. G.; Dumas, G.; Schinnerer, E.; Nagar, N.; Wilcots, E.; Wilson, A. S.; Emsellem, E.; Ferruit, P.; Peletier, R. F.; De Zeeuw, P. T.; Haan, S.

    Abstract: We are conducting the first systematic 3D spectroscopic imaging survey to quantify the properties of the atomic gas (HI) in a distance-limited sample of 28 Seyfert galaxies and a sample of 28 inactive control galaxies with well-matched optical properties (the VHIKINGS survey). This study

  8. Quantitative analysis of higher hydrocarbons in natural gas using coupled solid-phase extraction / supercritiacal fluid extraction with on-line GC analysis

    NARCIS (Netherlands)

    Janssen, J.G.M.; Cramers, C.A.M.G.; Meulen-Kuijk, van der L.; Smit, A.L.C.; Sandra, P.; Devos, G.

    1993-01-01

    Characterisation of natural gas with respect to the hydrocarbon content is a challenging analytical problem due to the extremely low concentrations and the complexity of the matrix. In this publication a method is described for fully on-line preconcentration and analysis of n-nonane and higher

  9. Ionisation of L subshells of heavy atoms by deuteron collision

    International Nuclear Information System (INIS)

    Sokhi, R.S.; Crumpton, D.; Trautmann, D.

    1989-01-01

    L i subshell ionisation cross sections for 1.2-3.0 MeV deuteron impact on thin targets of W, Au, Pb and Bi have been measured experimentally. Measurements were made with the Birmingham University's 3MV Dynamitron accelerator and the cross sections were deduced from the emitted L X-rays. These cross sections and their ratios have been compared graphically with the ECPSSR and RHSCA models. The ECPSSR model underestimates the measured L 2 subshell cross sections but shows very good agreement with the L 3 subshell values. The RHSCA theory in general exhibits good agreement with the measured cross sections for the L 1 and L 2 subshells but overestimates the L 3 cross sections by up to 60%. (orig.)

  10. Protection of the environment from ionising radiation: ethical issues

    International Nuclear Information System (INIS)

    Oughton, Deborah

    2003-01-01

    The paper identifies some of the main ethical issues concerning the protection of the environment from radiation and suggests ways in which ethics can aid in developing a system of protection. After a presentation of background on ethical theory and environmental ethics, three main issues related to environmental protection are discussed: First, the question of valuing the environment and implications for the definition of harm and monetary valuation of environmental goods; second, difficulties with scientific uncertainty and applications of the precautionary principle; and third, issues concerned with the distribution of risk and its relevance fo participation in decision-making. In summary, the paper argues that there are strong ethical grounds to provide for the protection of the environment and that, all other things being equal, there is no reason to treat ionising radiation differently to other environmental stressors

  11. Protection of the environment from ionising radiation: ethical issues.

    Science.gov (United States)

    Oughton, Deborah

    2003-01-01

    The paper identifies some of the main ethical issues concerning the protection of the environment from radiation and suggests ways in which ethics can aid in developing a system of protection. After a presentation of background on ethical theory and environmental ethics, three main issues related to environmental protection are discussed: First, the question of valuing the environment and implications for the definition of harm and monetary valuation of environmental goods; second, difficulties with scientific uncertainty and applications of the precautionary principle; and third, issues concerned with the distribution of risk and its relevance for participation in decision-making. In summary, the paper argues that there are strong ethical grounds to provide for the protection of the environment and that, all other things being equal, there is no reason to treat ionising radiation differently to other environmental stressors. Copyright 2002 Elsevier Science Ltd.

  12. The potential use of diamond coated tungsten tips as a field ionisation source

    Energy Technology Data Exchange (ETDEWEB)

    Brown, A.; Prawer, S.; Legge, G.J.F.; Kostidis, L.I. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1996-12-31

    Tungsten tips are convenient for use in a high brightness gaseous phase field ionisation source. However, the lifetime of these tips is not adequate for practical use. The authors are investigating whether coating tungsten tips with diamond using Chemical Vapor Deposition (CVD) will improve the practicality of using these tips by an improvement in longevity of the source and/or an improvement in brightness due to the effects of the property of negative electron affinity which has been observed on CVD diamond. 1 ref.

  13. The potential use of diamond coated tungsten tips as a field ionisation source

    Energy Technology Data Exchange (ETDEWEB)

    Brown, A; Prawer, S; Legge, G J.F.; Kostidis, L I [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1997-12-31

    Tungsten tips are convenient for use in a high brightness gaseous phase field ionisation source. However, the lifetime of these tips is not adequate for practical use. The authors are investigating whether coating tungsten tips with diamond using Chemical Vapor Deposition (CVD) will improve the practicality of using these tips by an improvement in longevity of the source and/or an improvement in brightness due to the effects of the property of negative electron affinity which has been observed on CVD diamond. 1 ref.

  14. Occupational radiation injuries from ionising rays recorded in the Federal Republic of Germany during the period between 1953 and 1979

    International Nuclear Information System (INIS)

    Soffke, R.

    1986-01-01

    An evaluation of 218 occupational diseases, which were reported between 1953 and 1979 and officially recognised as being caused by ionising rays, showed these to be made up chiefly by skin disorders (61%, equally distributed over acute and chronic forms), even though considerable percentage shares were also calculated for haematological ailments (15%) and bronchial carcinomas developed by uranium miners. There was a total of 42 deaths, 32 of which were ascribed to uranium mining and 10 to haematological diseases. In all, the annual rate of occupational diseases attributed to ionising rays shows a tendency to decline, even though the number of individuals exposed to radiation is increasing. The incidence of radiation injuries was calculated to be in the order of 0.01% for persons at risk of occupational radiation exposure. (orig./EDB) [de

  15. Equations for nickel-chromium wire heaters of column transfer lines in gas chromatographic-electroantennographic detection (GC-EAD).

    Science.gov (United States)

    Byers, John A

    2004-05-30

    Heating of chromatographic columns, transfer lines, and other devices is often required in neuroscience research. For example, volatile compounds passing through a capillary column of a gas chromatograph (GC) can be split, with half exiting the instrument through a heated transfer line to an insect antenna or olfactory sensillum for electroantennographic detector (GC-EAD) recordings. The heated transfer line is used to prevent condensation of various chemicals in the capillary that would otherwise occur at room temperature. Construction of such a transfer line heater is described using (80/20%) nickel-chromium heating wire wrapped in a helical coil and powered by a 120/220 V ac rheostat. Algorithms were developed in a computer program to estimate the voltage at which a rheostat should be set to obtain the desired heater temperature for a specific coil. The coil attributes (radius, width, number of loops, or length of each loop) are input by the user, as well as AWG size of heating wire and desired heater temperature. The program calculates total length of wire in the helix, resistance of the wire, amperage used, and the voltage to set the rheostat. A discussion of semiochemical isolation methods using the GC-EAD and bioassays is presented.

  16. On-line liquid chromatography-gas chromatography: A novel approach for the analysis of phytosterol oxidation products in enriched foods.

    Science.gov (United States)

    Scholz, Birgit; Wocheslander, Stefan; Lander, Vera; Engel, Karl-Heinz

    2015-05-29

    A novel methodology for the automated qualitative and quantitative determination of phytosterol oxidation products in enriched foods via on-line liquid chromatography-gas chromatography (LC-GC) was established. The approach is based on the LC pre-separation of acetylated phytosterols and their corresponding oxides using silica as stationary phase and a mixture of n-hexane/methyl tert-butyl ether/isopropanol as eluent. Two LC-fractions containing (i) 5,6-epoxy- and 7-hydroxyphytosterols, and (ii) 7-ketophytosterols are transferred on-line to the GC for the analysis of their individual compositions on a medium polar trifluoropropylmethyl polysiloxane capillary column. Thus, conventionally employed laborious off-line purification and enrichment steps can be avoided. Validation data, including recovery, repeatability, and reproducibility of the method, were elaborated using an enriched margarine as example. The margarine was subjected to a heating procedure in order to exemplarily monitor the formation of phytosterol oxidation products. Quantification was performed using on-line LC-GC-FID, identification of the analytes was based on on-line LC-GC-MS. The developed approach offers a new possibility for the reliable and fast analysis of phytosterol oxidation products in enriched foods. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Power plant including an exhaust gas recirculation system for injecting recirculated exhaust gases in the fuel and compressed air of a gas turbine engine

    Science.gov (United States)

    Anand, Ashok Kumar; Nagarjuna Reddy, Thirumala Reddy; Shaffer, Jason Brian; York, William David

    2014-05-13

    A power plant is provided and includes a gas turbine engine having a combustor in which compressed gas and fuel are mixed and combusted, first and second supply lines respectively coupled to the combustor and respectively configured to supply the compressed gas and the fuel to the combustor and an exhaust gas recirculation (EGR) system to re-circulate exhaust gas produced by the gas turbine engine toward the combustor. The EGR system is coupled to the first and second supply lines and configured to combine first and second portions of the re-circulated exhaust gas with the compressed gas and the fuel at the first and second supply lines, respectively.

  18. On-line non-contact gas analysis

    DEFF Research Database (Denmark)

    Fateev, Alexander; Clausen, Sønnik

    , and good agreement has been found for NO (e.g. deviations of 1-5% for NO at 1200 °C). Practical highresolution measurements at the AVV2 boiler are analysed, and detection limits for the NO are discussed. The developed tools and results will be used in the future projects, e.g. fast measurements of the gas...

  19. Health effects of low dose ionising radiation - recent advances and their implications

    International Nuclear Information System (INIS)

    1987-01-01

    The proceedings of this unusual interdisciplinary conference encompass the work of doctors, industrialists and civil servants. The discussion covers the investigation and quantification of dose response relationships for the various damaging effects of low level ionising radiation and a unified system for expressing biological damage, together with the results of epidemiological studies using models and data from the UK, Europe, Australia and the USA (including data base systems for assembling and validating data), the effects of background radiation (gamma ray and radon exposure), clustering studies, safety standards, radioactive waste discharge control and limitation through legislation and the monitoring of radioactivity in food. (author)

  20. Germany (Federal Republic). Ministry of the Interior. Order on protection against damage due to ionising radiation. Radiation Protectin Order. StrlSchV 20 Oct. 1976

    International Nuclear Information System (INIS)

    1977-02-01

    The order is arranged in parts, entitled: introductory provisions; control provisions (handling radioactive matter, the carriage of radioactive matter, the import and export of radioactive matter, the construction and operation of installation for generating ionising radiation, employees and other persons working under supervision, design approval); safety regulations (general regulations, protection of the population and the environment against the hazards of ionising radiation, occupational exposure to radiation, radiation protection areas, physical protection and control, medical supervision, instruments for measuring radiation, other safety regulations); fines; and final provisions. (U.K.)

  1. A cascade method of training for the revised CEGB Radiological Safety Rules and the Ionising Radiations Regulations 1985

    International Nuclear Information System (INIS)

    Jackson, J.R.; John, P.G.L.

    1986-01-01

    In order to achieve compliance with the Ionising Radiations Regulations 1985 the CEGB has introduced a revised set of Radiological Safety Rule. These Rules are for implementation at all sites under the Board's control where ionising radiations are used. It was a requirement that the new Safety Rules be brought into operation on a common date and to a consistent standard of performance throughout the industry; this necessitated a considerable training programme to familiarise and inform some 8,000 staff working at a large number of locations. The training week of identified groups of staff varied widely, according to their different levels of authority and responsibility. The paper sets out the means by which the chosen cascade method of training was selected and developed, and gives details of the modular package of training material which was produced. It also relates how the management objectives were met within the constraints of an uncompromising time schedule. (author)

  2. K-shell ionisation cross sections for W, Au and U by low velocity protons

    International Nuclear Information System (INIS)

    Castro Faria, N.V. de; Freire Junior, F.L.; Montenegro, E.C.; Pinho, A.G. de; Silveira, E.F. da.

    1984-01-01

    Proton-induced K-shell ionisation cross section for W, Au and U by low velocity protons were obtained from thick target measurements. For the first time the lowest incident energy reached a value less than 10 times the binding energy of the K-shell electron (less than 9 times in the case of Au). Possible errors are thoroughly examined and a comparison with other available experimental results and theoretical values is presented and discussed. (Author) [pt

  3. Risks of low dose ionising radiation exposures Riesgos derivados de la exposición a dosis bajas de radiación ionizante

    Directory of Open Access Journals (Sweden)

    Almudena Real Gallego

    2010-12-01

    Full Text Available Although ionising radiation has been shown to have several beneficial applications for humans, it can also produce detrimental effects in humans and the environment. To adequately protect man and environment from the potential harmful effects of ionising radiation, is essential to know in detail the biological effects produced by it, its characteristics and the various factors that influence these effects. That is the objective of this article, describe the current status of knowledge about biological effects induced by ionising radiation, with special emphasis on those effects occurring after low dose exposures.La radiación ionizante ha mostrado tener diversas aplicaciones beneficiosas para el hombre, pero también puede dañar la salud de las personas y el medio ambiente. Para proteger adecuadamente al hombre de los posibles efectos nocivos de la radiación ionizante es imprescindible conocer en detalle los efectos biológicos producidos por esta, sus características y los distintos factores que influyen en dichos efectos. Ese es el objetivo de este artículo: describir el estado actual del conocimiento sobre los efectos biológicos que puede producir la radiación ionizante, con especial énfasis en aquellos efectos que se producen tras la exposición a dosis bajas.

  4. Dégradation de lŽADN par les rayonnements ionisants. Influence de la structure et de lŽenvironnement

    Czech Academy of Sciences Publication Activity Database

    Maurizot, M.; Běgusová, Marie

    11-12 (2003), s. 97-102 ISSN 0151-9093 R&D Projects: GA AV ČR IAA1048103 Institutional research plan: CEZ:AV0Z1048901 Keywords : DNA * ionising radiations * hydroxyl radical Subject RIV: BO - Biophysics Impact factor: 0.112, year: 2003

  5. RedeGasEnergia - gas and energy excellence network: a strategy for development the Brazilian natural gas market; RedeGasEnergia - rede de excelencia de gas e energia: uma estrategia para o desenvolvimento do mercado do gas natural no Brasil

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Antonio L.F. dos [PETROBRAS, Rio de Janeiro, RJ (Brazil). Gerencia de Tecnologia do Gas Natural; Freire, Luiz G.M. [PETROBRAS, Rio de Janeiro, RJ (Brazil). Coordenacao de Tecnologia da RedeGasEnergia

    2004-07-01

    The present work aims at to present a new methodology of Excellency Net of Natural Gas - RedeGasEnergia for the development do natural gas market no Brazil, through in the application do model management for technologies associates different segments da economy: residential, commercial, industrial, Vehicle and of cogeneration, in accord with the Strategical Planning of the PETROBRAS. The developed methodology is based on the interaction enters the technological lines of direction of the segments of the economy and marketing lines of direction, inside of a corporative environment enters the some agents of the productive chain of the Natural Gas, which is: University, the delivering and transporting Institutions of Research and Technologies (technological arm) and companies of NG, municipal, state and federal equipment manufacturers (enterprise arm) and agencies, trade associations (governmental arm) to which of integrated and articulated form carry through a sustainable development of the Natural Gas market in Brazil. A study of case of the methodology will be shown, from the analysis of the current scenes of the use of the natural gas in light vehicles and weighed, locomotives and boats, as well as the available infrastructure for the Vehicle applications. (author)

  6. Effects of small doses of ionising radiation

    International Nuclear Information System (INIS)

    Doll, R.

    1998-01-01

    Uncertainty remains about the quantitative effects of doses of ionising radiation less than 0.2 Sv. Estimates of hereditary effects, based on the atomic bomb survivors, suggest that the mutation doubling dose is about 2 Sv for acute low LET radiation, but the confidence limits are wide. The idea that paternal gonadal irradiation might explain the Seascale cluster of childhood leukaemia has been disproved. Fetal irradiation may lead to a reduction in IQ and an increase in seizures in childhood proportional to dose. Estimates that doses to a whole population cause a risk of cancer proportional to dose, with 0.1 Sv given acutely causing a risk of 1%, will need to be modified as more information is obtained, but the idea that there is a threshold for risk above this level is not supported by observations on the irradiated fetus or the effect of fallout. The idea, based on ecological observations, that small doses protect against the development of cancer is refuted by the effect of radon in houses. New observations on the atomic bomb survivors have raised afresh the possibility that small doses may also have other somatic effects. (author)

  7. Microdosimetric constraints on specific adaptation mechanisms to reduce DNA damage caused by ionising radiation

    International Nuclear Information System (INIS)

    Burkart, W.; Heusser, P.; Vijayalaxmi

    1990-01-01

    The protective effect of pre-exposure of lymphocytes to ionising radiation indicates the presence of 'adaptive repair' in mammalian cells. Microdosimetric considerations, however, raise some doubts on the advantage of such a cellular mechanism for specifically reducing the radiation damage caused by environmental exposures. Contrary to most chemicals which endanger the integrity of the mammalian genome, the local dose and dose rate from ionising radiation at the cellular level remain quite high, even at lowest exposures. A single electron or alpha particle passing through a cell nucleus already yields nuclear doses of up to about 3 mGy and 400 mGy, respectively. Macroscopic doses below these nuclear doses from a single event will only reduce the fraction of cell nuclei encountering the passage of a particle but not the dose or dose rate in the affected volume. At environmental doses in the range of 1 to 5 mGy per annum, the time between two consecutive hits in a specific cell nucleus is in the range of months to years. Very low concentrations of bleomycin, a drug with high affinity to DNA, also triggers an adaptive response. This points to a more general stress response mechanism which may benefit the cell even at environmental levels of radioactivity, e.g. by protecting the integrity of DNA from attacks by chemicals, by endogenous radicals, by acids from anoxia, etc. (author)

  8. Lactobacilli and ionising radiation: an example of the application to meat and meat products. Laktobazillen und ionisierende Strahlung als Beispiel einer Anwendung auf Fleisch und Fleischprodukte

    Energy Technology Data Exchange (ETDEWEB)

    Holzapfel, W.H. (Inst. fuer Hygiene und Toxikologie, Bundesforschungsanstalt fuer Ernaehrung, Karlsruhe (Germany))

    1992-01-01

    Ionising radiation provides a practical pasteurisation method for the terminal treatment of refrigerated vacuum-packaged meat products with the aim of shelf life extension. However, the relatively high radiation resistance ([gamma]-D[sub 10] = 0.70-1.2 kGy) of typical meat Lactobacilli, especially Lb. sake, selectively favours their total domination after treatments with 5 kGy. Typical meat strains show higher resistance (in term of [gamma]-D[sub 10] values the decimal reduction value due to irradiation) in the log (exponential) than in the stationary phase. This phenomenon was observed both in semi-synthetic broth and in meat, and may be explained in terms of a DNA repair mechanism operative during the exponential phase. Packaging under different gas atmospheres resulted in increased resistance to radiation in presence of N[sub 2], whilst the highest death rate was observed in presence of CO[sub 2]. (orig.)

  9. Directed line liquids

    International Nuclear Information System (INIS)

    Kamien, R.D.

    1992-01-01

    This thesis is devoted to the study of ensembles of dense directed lines. These lines are principally to be thought of as polymers, though they also have the morphology of flux lines in high temperature superconductors, strings of colloidal spheres in electrorheological fluids and the world lines of quantum mechanical bosons. The authors discuss how directed polymer melts, string-like formations in electrorheological and ferro-fluids, flux lines in high temperature superconductors and the world lines of quantum mechanical bosons all share similar descriptions. They study a continuous transition in all of these systems, and then study the critical mixing properties of binary mixtures of directed polymers through the renormalization group. They predict the exponents for a directed polymer blend consolute point and a novel two-phase superfluid liquid-gas critical point

  10. Thermal Boundary Layer Effects on Line-of-Sight Tunable Diode Laser Absorption Spectroscopy (TDLAS) Gas Concentration Measurements.

    Science.gov (United States)

    Qu, Zhechao; Werhahn, Olav; Ebert, Volker

    2018-06-01

    The effects of thermal boundary layers on tunable diode laser absorption spectroscopy (TDLAS) measurement results must be quantified when using the line-of-sight (LOS) TDLAS under conditions with spatial temperature gradient. In this paper, a new methodology based on spectral simulation is presented quantifying the LOS TDLAS measurement deviation under conditions with thermal boundary layers. The effects of different temperature gradients and thermal boundary layer thickness on spectral collisional widths and gas concentration measurements are quantified. A CO 2 TDLAS spectrometer, which has two gas cells to generate the spatial temperature gradients, was employed to validate the simulation results. The measured deviations and LOS averaged collisional widths are in very good agreement with the simulated results for conditions with different temperature gradients. We demonstrate quantification of thermal boundary layers' thickness with proposed method by exploitation of the LOS averaged the collisional width of the path-integrated spectrum.

  11. Condensation in gas transmission pipelines. Phase behavior of mixtures of hydrogen with natural gas

    Energy Technology Data Exchange (ETDEWEB)

    Schouten, J.A.; Michels, J.P.J. [Amsterdam Univ. (Netherlands). Van der Waals-Zeeman Inst.; Rosmalen, R.J. van [Energy, Roden (Netherlands)

    2005-05-01

    Several pressure and temperature reductions occur along gas transmission lines. Since the pressure and temperature conditions of the natural gas in the pipeline are often close to the dew point curve, liquid dropout can occur. Injection of hydrogen into the natural gas will change the phase envelope and thus the liquid dropout. This condensation of the heavy hydrocarbons requires continuous operational attention and a positive effect of hydrogen may affect the decision to introduce hydrogen. In this paper we report on calculations of the amount of condensate in a natural gas and in this natural gas mixed with 16.7% hydrogen. These calculations have been performed at conditions prevailing in gas transport lines. The results will be used to discuss the difference in liquid dropout in a natural gas and in a mixture with hydrogen at pressure reduction stations, at crossings under waterways, at side-branching, and at separators in the pipelines. (author)

  12. Clues to Quasar Broad Line Region Geometry and Kinematics

    DEFF Research Database (Denmark)

    Vestergaard, Marianne; Wilkes, B. J.; Barthel, P. D.

    2000-01-01

    width to show significant inverse correlations with the fractional radio core-flux density, R, the radio axis inclination indicator. Highly inclined systems have broader line wings, consistent with a high-velocity field perpendicular to the radio axis. By contrast, the narrow line-core shows...... no such relation with R, so the lowest velocity CIV-emitting gas has an inclination independent velocity field. We propose that this low-velocity gas is located at higher disk-altitudes than the high-velocity gas. A planar origin of the high-velocity CIV-emission is consistent with the current results...... and with an accretion disk-wind emitting the broad lines. A spherical distribution of randomly orbiting broad-line clouds and a polar high-ionization outflow are ruled out....

  13. Laser-based absorption spectroscopy as a technique for rapid in-line analysis of respired gas concentrations of O2 and CO2.

    Science.gov (United States)

    Cummings, Beth; Hamilton, Michelle L; Ciaffoni, Luca; Pragnell, Timothy R; Peverall, Rob; Ritchie, Grant A D; Hancock, Gus; Robbins, Peter A

    2011-07-01

    The use of sidestream analyzers for respired gas analysis is almost universal. However, they are not ideal for measurements of respiratory gas exchange because the analyses are both temporally dissociated from measurements of respiratory flow and also not generally conducted under the same physical conditions. This study explores the possibility of constructing an all optical, fast response, in-line breath analyzer for oxygen and carbon dioxide. Using direct absorption spectroscopy with a diode laser operating at a wavelength near 2 μm, measurements of expired carbon dioxide concentrations were obtained with an absolute limit of detection of 0.04% at a time resolution of 10 ms. Simultaneously, cavity enhanced absorption spectroscopy at a wavelength near 760 nm was employed to obtain measurements of expired oxygen concentrations with an absolute limit of detection of 0.26% at a time resolution of 10 ms. We conclude that laser-based absorption spectroscopy is a promising technology for in-line analysis of respired carbon dioxide and oxygen concentrations.

  14. Recommendations for main line block valves installation in gas pipelines; Recomendacoes para instalacao de valvulas de bloqueio de linha tronco em gasodutos

    Energy Technology Data Exchange (ETDEWEB)

    Frisoli, Caetano [TRANSPETRO - PETROBRAS Transportes, Rio de Janeiro, RJ (Brazil); Oliveira, Valeriano Duque de [PETROBRAS, Rio de Janeiro, RJ (Brazil)

    2003-07-01

    Cases of gas pipelines block valves and its pneumatic actuators presenting problems during the final pipeline commissioning and pre-operation phases, like internal leaks, leaking to the atmosphere, pneumatic circuit defects caused by water and debris, are nearly common. The majority can be avoided if a series of measuring are to be planned and implemented, as well as if an adequate planning of commissioning operations and line gasification, valves and actuators, are to be applied. This paper shows the practical experience in the construction and commissioning of valves and its actuators in the Bolivia-Brazil gas pipeline, which, in the first construction phase had a series of problems. After the diagnosis a set of procedures was implemented in the secondary construction phase, resulting in insignificant problems detected. All measures and procedures taken in the planning process, as well as additional aspects related to the main line valve design, its by-passes and supports, are demonstrated. (author)

  15. The gas-phase on-line production of phosphoryl halides, Pox3 and their identification by infrared spectroscopy

    International Nuclear Information System (INIS)

    Allaf, A.W.

    1998-01-01

    A new route has been devised, leading to the production of Pox 3 molecules where X=F, Br and I by an on-line process using phosphoryl chloride, POCL 3 as a starting material passed over heated sodium fluoride, NaF, potassium bromide, KBr and potassium iodide, K1 at 535 Centigrade, 690 Centigrade and 480 Centigrade, respectively. The low resolution gas-phase fourier transform infrared spectra reported for the first time showed strong bands centered at 1411.6, 1322.9, 1300.8 and 1285 cm - 1, assigned to Ε 1 (a 1 ), the O = P stretching fundamental of POF 3 , POCL 3 , POBR 3 and POI 3 , respectively. Attempts were made to prepare POCL 2 and POBr 2 , by an on-line process using POCL 3 again but passed over heated sodium and potassium bromide for POCL 2 and POBr 2 . (author). 3 refs., 2 figs., 1 tab

  16. Simultaneous influence of Stark effect and excessive line broadening on the Hα line

    Science.gov (United States)

    Cvetanović, Nikola; Ivković, Saša S.; Obradović, Bratislav M.; Kuraica, Milorad M.

    2017-12-01

    The aim of this paper is to study the combined influence of the Stark effect and the excessive Doppler broadening on the Balmer alpha line in hydrogen discharges. Since this line is a good candidate for measuring electric field in various types of discharges with different gas compositions, a simple method for field measurement based on polarization spectroscopy is developed, that includes all the excitation mechanisms. To simultaneously test the flexibility of the fitting procedure and investigate the excessive broadening, we applied the fitting procedure on line profiles obtained at a range of conditions from two different discharges. The range of pressures and voltages was examined in an abnormal glow and in dielectric barrier discharge operating with hydrogen gas. The model fitting function was able to respond and follow the change in the line profile caused by the change of conditions. This procedure can therefore be recommended for electric field measurement. Contribution to the "Topical Issue: Physics of Ionized Gases (SPIG 2016)", edited by Goran Poparic, Bratislav Obradovic, Dragana Maric and Aleksandar Milosavljevic.

  17. Dedicated Trigger for Highly Ionising Particles at ATLAS

    CERN Document Server

    Katre, Akshay; The ATLAS collaboration

    2015-01-01

    In 2012, a novel strategy was designed to detect signatures of Highly Ionising Particles (HIPs) such as magnetic monopoles, dyons or Qballs with the ATLAS trigger system. With proton-proton collisions at a centre of mass enegy of 8 TeV, the trigger was designed to have unique properties as a tracker for HIPs. It uses only the Transition Radiation Tracker (TRT) system, applying an algorithm distinct from standard tracking ones. The unique high threshold readout capability of the TRT is used at the location where HIPs in the detector are looked for. In particular the number and the fraction of TRT high threshold hits is used to distinguish HIPs from background processes. The trigger requires significantly lower energy depositions in the electro-magnetic calorimeters as a seed unlike previously used trigger algorithms for such searches. Thus the new trigger is capable of probing a large range of HIP masses and charges. We will give a description of the algorithms for this newly developed trigger for HIP searches...

  18. Simulation bidimensional of water and gas alternative injection; Simulacao bidimensional de injecao alternada de agua e gas

    Energy Technology Data Exchange (ETDEWEB)

    Santana, Ana Paula Silva C. de

    1999-07-01

    This dissertation presents a study of the unidimensional of water and gas alternate injection (WAG) using the stream line theory. It is considered incompressible fluid., unit mobility ratio, negligible capillary and gravitational effects, homogeneous and isotropic reservoir, isothermal flow two phases, oil and water, and three components, oil, water and gas. In the stream line theory, the following injection schemes are considered: staggered line five-spot, direct line and seven-spot. It is also considered that there is no flow among the streams. In the WAG calculations it is used the fractional flow theory and the method of characteristics, which consists of shock waves and rarefactions. The composition of these waves is said compatible if it satisfies the entropy condition. The solution goes through a certain path from the left to the right side constrained by the initial and boundary conditions. The gas injection is at a high pressure to ensure miscible displacement. It is considered first injection of a water bank and then, injection of a gas bank. We concluded that the gas injection at a high pressure recoveries all residual oil and the water saturation remains is greater than initial saturation. (author)

  19. Papers of a Canadian Institute conference : Unconventional gas symposium : Tight gas, gas shales, coalbed methane, gas hydrates

    International Nuclear Information System (INIS)

    2003-01-01

    This symposium provided an opportunity for participants to learn from gas industry leaders in both Canada and the United States, different strategies to cost-effectively develop unconventional gas resources. In particular, the representative from EnCana Corporation discussed the results of tight gas drilling in Northeastern British Columbia. The speaker for MGV Energy reported on the outcome of test drilling for coalbed methane (CBM) in Southern Alberta. The economic development of tight gas reservoirs in the United States Permian Basin was discussed by the speaker representing BP America Production Company. The role of unconventional gas in the North American natural gas supply and demand picture was dealt with by TransCanada PipeLines Limited and Canadian Gas Potential Committee. The trend for natural gas prices in North America was examined by Conoco Inc. The Geological Survey of Canada addressed the issue of gas hydrate potential in the Mackenzie Delta Mallik Field. In addition, one presentation by El Paso Production Company discussed the successful drilling for deep, tight gas and CBM in the United States. There were nine presentations at this symposium, of which three were indexed separately for inclusion in this database. refs., tabs., figs

  20. Burnable gas concentration control device

    International Nuclear Information System (INIS)

    Goto, Hiroshi; Sanada, Takahiro; Kuboniwa, Takao.

    1980-01-01

    Purpose: To provide connecting ports by doubling nitrogen gas injection pipes thereby to secure lengthiness of the device only by providing one nitrogen gas generator. Constitution: Nitrogen gas injection pipes are provided in two lines separately, and attachable and detachable connecting ports for feeding nitrogen gas connectable to a movable type nitrogen gas supply installation for the purpose of backing up the nitrogen gas generator. (Yoshihara, H.)

  1. On-line monitoring of methanol and methyl formate in the exhaust gas of an industrial formaldehyde production plant by a mid-IR gas sensor based on tunable Fabry-Pérot filter technology.

    Science.gov (United States)

    Genner, Andreas; Gasser, Christoph; Moser, Harald; Ofner, Johannes; Schreiber, Josef; Lendl, Bernhard

    2017-01-01

    On-line monitoring of key chemicals in an industrial production plant ensures economic operation, guarantees the desired product quality, and provides additional in-depth information on the involved chemical processes. For that purpose, rapid, rugged, and flexible measurement systems at reasonable cost are required. Here, we present the application of a flexible mid-IR filtometer for industrial gas sensing. The developed prototype consists of a modulated thermal infrared source, a temperature-controlled gas cell for absorption measurement and an integrated device consisting of a Fabry-Pérot interferometer and a pyroelectric mid-IR detector. The prototype was calibrated in the research laboratory at TU Wien for measuring methanol and methyl formate in the concentration ranges from 660 to 4390 and 747 to 4610 ppmV. Subsequently, the prototype was transferred and installed at the project partner Metadynea Austria GmbH and linked to their Process Control System via a dedicated micro-controller and used for on-line monitoring of the process off-gas. Up to five process streams were sequentially monitored in a fully automated manner. The obtained readings for methanol and methyl formate concentrations provided useful information on the efficiency and correct functioning of the process plant. Of special interest for industry is the now added capability to monitor the start-up phase and process irregularities with high time resolution (5 s).

  2. Photoionization-driven Absorption-line Variability in Balmer Absorption Line Quasar LBQS 1206+1052

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Luming; Zhou, Hongyan; Ji, Tuo; Jiang, Peng; Liu, Bo; Pan, Xiang; Shi, Xiheng; Zhang, Shaohua [Polar Research Institute of China, 451 Jinqiao Road, Shanghai (China); Liu, Wenjuan; Wang, Jianguo [Yunnan Observatories, Chinese Academy of Sciences, Kunming, Yunnan (China); Wang, Tinggui; Yang, Chenwei [Department of Astronomy, University of Science and Technology of China, 96 Jinzhai Road, Hefei, Anhui (China); Miller, Lauren P., E-mail: lmsun@mail.ustc.edu.cn [Lehigh University, 27 Memorial Drive West, Bethlehem, PA 18015 (United States)

    2017-04-01

    In this paper we present an analysis of absorption-line variability in mini-BAL quasar LBQS 1206+1052. The Sloan Digital Sky Survey spectrum demonstrates that the absorption troughs can be divided into two components of blueshift velocities of ∼700 and ∼1400 km s{sup −1} relative to the quasar rest frame. The former component shows rare Balmer absorption, which is an indicator of high-density absorbing gas; thus, the quasar is worth follow-up spectroscopic observations. Our follow-up optical and near-infrared spectra using MMT, YFOSC, TSpec, and DBSP reveal that the strengths of the absorption lines vary for both components, while the velocities do not change. We reproduce all of the spectral data by assuming that only the ionization state of the absorbing gas is variable and that all other physical properties are invariable. The variation of ionization is consistent with the variation of optical continuum from the V -band light curve. Additionally, we cannot interpret the data by assuming that the variability is due to a movement of the absorbing gas. Therefore, our analysis strongly indicates that the absorption-line variability in LBQS 1206+1052 is photoionization driven. As shown from photoionization simulations, the absorbing gas with blueshift velocity of ∼700 km s{sup −1} has a density in the range of 10{sup 9} to 10{sup 10} cm{sup −3} and a distance of ∼1 pc, and the gas with blueshift velocity of ∼1400 km s{sup −1} has a density of 10{sup 3} cm{sup −3} and a distance of ∼1 kpc.

  3. Annual report on theoretical work of the S.T.G.I. (Section de theorie des gaz ionises)

    International Nuclear Information System (INIS)

    1984-01-01

    This report presents in a detailed form the theoretical work of the STGI (Section Theorie des Gaz Ionises). It is thus hoped that the present report will be useful for physicists interested in additional information. Works an plasma equilibrium and its evolution are shortly presented together with works on plasma heating and current drive. Kinetic theory and spectroscopy are not forgotten

  4. Identification of Wheat Varieties Using Matrix-assisted Laser Desorption/Ionisation Time-of-flight Mass Spectrometry and an Artificial Neural network

    DEFF Research Database (Denmark)

    Bloch, Helle Aagaard; Kesmir, Can; Petersen, Marianne Kjerstine

    1999-01-01

    A novel tool for variety identification of wheat (Triticum aestivum L,) has been developed: an artificial neural network (ANN) is used to classify the gliadin fraction analysed by matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI-TOFMS). The robustness...

  5. Proton and electron impact on molecular and atomic oxygen: I. High resolution fluorescence spectra in the visible and VUV spectral range and emission cross-sections for dissociative ionisation and excitation of O2

    International Nuclear Information System (INIS)

    Wilhelmi, O.; Schartner, K.H.

    2000-01-01

    For pt.II see ibid., vol.11, p.45-58, 2000. Molecular oxygen O 2 was dissociated in collisions with protons and electrons in the intermediate velocity range (p + -energies: 17-800 keV, e - -energies: 0.2-2 keV). Fluorescence from excited atomic and singly ionised fragments and from singly ionised molecules was detected in the VUV and in the visible and near UV spectral range. Highly resolved spectra are presented for the VUV (46-131 nm) and the near UV/visible (340-605 nm) spectral range. Absolute emission cross-sections have been determined for dissociative ionisation and excitation leading to fluorescence in the VUV. Results are compared with published data. (orig.)

  6. Ionising radiation and risk of death from leukaemia and lymphoma in radiation-monitored workers (INWORKS)

    Energy Technology Data Exchange (ETDEWEB)

    Lorenz, Bernd

    2015-07-01

    Since July 2015 the study ''ionising radiation and risk of death from leukaemia and lymphoma in radiation-monitored workers (INWORKS) - an international cohort study'' is available. INWORKS comprised data from 300.000 occupational exposed and dosimetric monitored persons from France, USA and UK. The contribution is a critical discussion of this study with respect to the conclusion of a strong evidence of positive associations between protracted low-dose irradiation exposure and leukemia.

  7. Decontamination of hospital wastes by the combined action of ionising radiation and heat - the thermorad process

    International Nuclear Information System (INIS)

    Icre, P.; Rocquigny, H. de

    1995-01-01

    The Thermorad process is used for decontaminating hospital wastes at the hospital as they are collected from the different departments. The process utilises the combined microbiological effects of ionising radiation (5 kGy) and dry heat (60 o C). The treatment unit, which is compact and of small size, contains a cobalt 60 source of under 100,000 curies and has an annual treatment capacity of 5000 m 3 . (author)

  8. Applying the ionising radiation regulations to radon in the UK workplace

    International Nuclear Information System (INIS)

    Denman, A. R.

    2008-01-01

    As a response to the identification of a health risk from workplace radon in the UK, the Ionising Radiations Regulations include the protection of workers from excessive levels of radon. Employers are required to make risk assessments, and the interpretation of the Health and Safety Executive is that the regulations apply to workplace premises in locations already designated as Radon Affected Areas for domestic purposes, with the difference that in workplaces, it is the maximum winter radon concentration rather than the annual average which is the parameter of interest. This paper discusses the rationale behind the current regulatory environment, outlines the role and duties of Accredited Radiation Protection Advisers and summarises the strategies necessary to conform to the regulations. (authors)

  9. The low dose gamma ionising radiation impact upon cooperativity of androgen-specific proteins.

    Science.gov (United States)

    Filchenkov, Gennady N; Popoff, Eugene H; Naumov, Alexander D

    2014-01-01

    The paper deals with effects of the ionising radiation (γ-IR, 0.5 Gy) upon serum testosterone (T), characteristics of testosterone-binding globulin (TeBG) and androgen receptor (AR) in parallel with observation of androgen (A) responsive enzyme activity - hexokinase (HK). The interdependence or relationships of T-levels with parameters of the proteins that provide androgenic regulation are consequently analyzed in post-IR dynamics. The IR-stress adjustment data reveal expediency of TeBG- and AR-cooperativity measurements for more precise assessments of endocrine A-control at appropriate emergencies. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Epidemiological methods of assessing risks from low level occupational exposure to ionising radiation

    International Nuclear Information System (INIS)

    Reissland, J.A.

    1982-01-01

    The resolution of radiation-attributable malignancies from the background of malignancies which are responsible for about 20% of all deaths in the Western world, presents a formidable challenge to epidemiological methods. Some of the major difficulties facing those with the task of estimating the risks associated with exposure to low level ionising radiation are discussed, particularly in the context of radiological protection. Some of the studies currently in progress are summarised and suggestions are made for other work which may help to contribute to a better understanding of the quantitative aspects of radiation risk assessment. (author)

  11. Radicals of DNA and DNA nucleotides generated by ionising radiation

    International Nuclear Information System (INIS)

    Przybytniak, G.

    2004-01-01

    A first stage of cell processes leading to DNA damage of initiated by radical reactions. In a model system such transformations were generated by ionising radiation which involves production of electron loss and electron gain centers of the substrate and radical formation. Using cryogenic ESR spectroscopy it was found that the DNA nucleotides, which convert to radical anions upon electron capture undergo the separation of unpaired spin and charge due to protonation. Circular and linear dichroism studies enabled to conclude that iron ions(III) induce strong changes in the DNA helical structure indicating their coordination with nitrogen bases. The repair of DNA radicals produced via radiolytic oxidation, i.e. the guanine radical cation and the allyl type radical of thymine, is possible at elevated temperatures due to the involvement of sulphydryl groups. The influence of the thiol charge is then limited

  12. Molecular gas in dusty high-redshift galaxies

    Science.gov (United States)

    Sharon, Chelsea Electra

    2013-12-01

    We present high-resolution observations of carbon monoxide (CO) emission lines for three high-redshift galaxies in order to determine their molecular gas and star formation properties. These galaxies (SMM J14011+0252, SMM J00266+1708, and SDSS J0901+1814) have large infrared luminosities, which imply high dust enshrouded star formation rates and substantial molecular gas masses. We observed these sources using the Robert C. Byrd Green Bank Telescope, the Karl G. Jansky Very Large Array, the Plateau de Bure Interferometer, and the Submillimeter Array in order to obtain measurements of multiple CO spectral lines, allowing us to determine the physical conditions of the molecular gas. Our high resolution and multi-line CO mapping of SMM J00266+1708 reveals that it is a pair of merging galaxies, whose two components have different gas excitation conditions and different gas kinematics. For SMM J14011+0252 (J14011), we find a near-unity CO(3--2)/CO(1--0) intensity ratio, consistent with a single phase (i.e., a single temperature and density) of molecular gas and different from the average population value for dusty galaxies selected at submillimeter wavelengths. Our radiative transfer modeling (using the large velocity gradient approximation) indicates that converting the CO line luminosity to molecular gas mass requires a Galactic (disk-like) scale factor rather than the typical conversion factor assumed for starbursts. Despite this choice of conversion factor, J14011 falls in the same region of star formation rate surface density and gas mass surface density (the Schmidt-Kennicutt relation) as other starburst galaxies. SDSS J0901+1814 (J0901) was initially selected as a star-forming galaxy at ultraviolet wavelengths, but also has a large infrared luminosity. We use the magnification provided by the strong gravitational lensing affecting this system to examine the spatial variation of the CO excitation within J0901. We find that the CO(3--2)/CO(1--0) line ratio is

  13. Emissions and doses from sources of ionising radiation in the Netherlands: radiation policy monitoring

    International Nuclear Information System (INIS)

    Eleveld, H.; Pruppers, M.

    2002-01-01

    In 1997 the Ministry of Housing, Spatial Planning and the Environment requested RIVM to develop an information system for policy monitoring. One of the motives was that the European Union requires that the competent authorities of each member state ensure that dose estimates due to practices involving exposure to ionising radiation are made as realistic as possible for the population as a whole and for reference groups in all places where such groups may occur. Emissions of radionuclides and radiation to the environment can be classified as follows: (1) emissions to the atmosphere, (2) emissions to the aquatic system and (3) emission of external radiation from radioactive materials and equipment that produces ionising radiation. Released radioactivity is dispersed via exposure pathways, such as the atmosphere, deposition on the ground and farmland products, drinking water, fish products, etc. This leads to radiation doses due to inhalation, ingestion and exposure to external radiation. To assess the possible radiation doses different kinds of models are applied, varying from simple multiplications with dispersion coefficients, transfer coefficients and dose conversion coefficients to complex dispersion models. In this paper an overview is given of the human-induced radiation doses in the Netherlands. Also, trends in and the effect of policy on the radiation dose of members of the public are investigated. This paper is based on an RIVM report published recently. A geographical distribution of radiation risks due to routine releases for a typical year in the Netherlands was published earlier

  14. Innovative in-line separators: removal of water or sand in oil/water and gas/liquid/solid pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Jepson, Paul; Cheolho Kang; Gopal, Madan [CC Technologies, Dublin, OH (United States)

    2003-07-01

    In oil and gas production, multiphase mixtures are often separated before downstream processing. The separators are large, often 20 - 40 feet long and large diameter and use sophisticated internals. The costs are in the millions of dollars. Further, the sand and water in the flow can cause severe internal erosion and corrosion respectively before the flow reaches the separators. The CC Technologies/MIST In line Separation System is a cost-effective, efficient device for use in multiphase environments. The device is applicable for gas/solid, gas/liquid/solid and oil/water systems and offers exceptional separation between phases for a fraction of the cost of expensive gravity separators and hydro cyclones. The System contains no moving parts and is designed to be of the same diameter as the pipe, and experiences low shear forces. It can be fabricated with standard pipes. The efficiency of the separator has been determined in an industrial scale, pilot plant test facility at CC Technologies in 4-inch diameter pipes and has been found to be in excess of 98-99% for the removal of sand. Two phase oil/water separation effectiveness is in excess of 90% in 1-stage and 95% in 2 - stage. (author)

  15. Detecting metal-poor gas accretion in the star-forming dwarf galaxies UM 461 and Mrk 600

    Science.gov (United States)

    Lagos, P.; Scott, T. C.; Nigoche-Netro, A.; Demarco, R.; Humphrey, A.; Papaderos, P.

    2018-03-01

    Using VIMOS-IFU observations, we study the interstellar medium (ISM) of two star-forming dwarf galaxies, UM 461 and Mrk 600. Our aim was to search for the existence of metallicity inhomogeneities that might arise from infall of nearly pristine gas feeding ongoing localized star-formation. The IFU data allowed us to study the impact of external gas accretion on the chemical evolution as well as the ionised gas kinematics and morphologies of these galaxies. Both systems show signs of morphological distortions, including cometary-like morphologies. We analysed the spatial variation of 12 + log(O/H) abundances within both galaxies using the direct method (Te), the widely applied HII-CHI-mistry code, as well as by employing different standard calibrations. For UM 461 our results show that the ISM is fairly well mixed, at large scales, however we find an off-centre and low-metallicity region with 12 + log(O/H) ISM in our analysed galaxies are consistent with these systems being at different evolutionary stages.

  16. Desorption electrospray ionisation mass spectrometry: A rapid screening tool for veterinary drug preparations and forensic samples from hormone crime investigations

    NARCIS (Netherlands)

    Nielen, M.W.F.; Hooijerink, H.; Claassen, F.C.; Engelen, M.C.; Beek, van T.A.

    2009-01-01

    Hormone and veterinary drug screening and forensics can benefit from the recent developments in desorption electrospray ionisation (DESI) mass spectrometry (MS). In this work the feasibility of DESI application has been studied. Using a linear ion trap or quadrupole time-of-flight (TOF) MS

  17. Gas turbine cleaning upgrade (compressor wash)

    Energy Technology Data Exchange (ETDEWEB)

    Asplund, P [Gas Turbine Efficiency, Jarfalla (Sweden)

    1999-12-31

    The influence of gas turbine degradation on operating costs is high. Gas turbine cleaning is one of many actions taken for power recovery and is to consider as preventive maintenance. It is generally performed within the industrial field and occasionally within the aero sector. In order to meet the gas turbine development win high blade loads and ever-increasing temperatures, together with emission Aces and environmental regulations, more efficient and careful cleaning methods are needed. Following a survey about potentials for cost reduction in gas turbine operation a new man-hour and water saving cleaning method has been evaluated for a standard process. Compared with traditional cleaning methods, the new method is water,- cost,- weight and space saving due to a new washing technique. Traditional methods are based on using different nozzles for ON and OFF-line cleaning, which rise the demand for complicated systems. In the new method the same nozzle installation, same liquid flow and pressure is used for both ON and OFF-line cleaning. This gives a cost reduction of appr. 20.000 - 30.000 USD per gas turbine depending on installation and size. Evaluation of the new method shows significantly improved ON -line cleaning performance and thus OFF -line cleaning is required only during scheduled stops. (orig.) 10 refs.

  18. Gas turbine cleaning upgrade (compressor wash)

    Energy Technology Data Exchange (ETDEWEB)

    Asplund, P. [Gas Turbine Efficiency, Jarfalla (Sweden)

    1998-12-31

    The influence of gas turbine degradation on operating costs is high. Gas turbine cleaning is one of many actions taken for power recovery and is to consider as preventive maintenance. It is generally performed within the industrial field and occasionally within the aero sector. In order to meet the gas turbine development win high blade loads and ever-increasing temperatures, together with emission Aces and environmental regulations, more efficient and careful cleaning methods are needed. Following a survey about potentials for cost reduction in gas turbine operation a new man-hour and water saving cleaning method has been evaluated for a standard process. Compared with traditional cleaning methods, the new method is water,- cost,- weight and space saving due to a new washing technique. Traditional methods are based on using different nozzles for ON and OFF-line cleaning, which rise the demand for complicated systems. In the new method the same nozzle installation, same liquid flow and pressure is used for both ON and OFF-line cleaning. This gives a cost reduction of appr. 20.000 - 30.000 USD per gas turbine depending on installation and size. Evaluation of the new method shows significantly improved ON -line cleaning performance and thus OFF -line cleaning is required only during scheduled stops. (orig.) 10 refs.

  19. Line-shape asymmetry of water vapor absorption lines in the 720-nm wavelength region

    Science.gov (United States)

    Grossmann, Benoist E.; Browell, Edward V.

    1991-01-01

    Spectral line-shape analyses were performed for water vapor lines broadened by argon, oxygen, and xenon in the 720-nm wavelength region. A line-shape asymmetry was observed, which is attributed to statistical dependence or correlation between velocity- and state-changing collisions. The generalized (asymmetric) Galatry profile, which results from the soft-collision profile and includes correlation between velocity- and state-changing collisions, was fitted to the observed line shapes and was found to compare favorably with the observed data. The most prominent asymmetries were observed with xenon as the buffer gas.

  20. Nonuniform distribution of gas-liquid system in gas-distributing collector

    Energy Technology Data Exchange (ETDEWEB)

    Kasimov, R.Sh.; Abdullayev, E.A.; Eyubov, A.A.; Khudobakhshiyev, M.R.

    1979-01-01

    In the example of studying GS-1 of the field Shatlyk, the effect of nonuniform distribution of the liquid phase is examined (hydrocarbon condensate, water) on production lines of the unit of low temperature separation on the process of field preparation of gas. In particular, the unequal efficiency of single-type equipment operating under comparable conditions is noted: differences in the magnitude of under recuperation of coal of the recuperation heat exchangers, in the values of the integrated effect of Joule-Thomson, the coefficients of removal of low-temperature separators, etc. A consequence of this situation is deterioration in the quality of gas fed to the main pipe line. It is suggested that efforts be concentrated on developing technical designs which guarantee uniform supply of liquid from the field collector to the production lines of the unit for low temperature separation.

  1. Radiographic imaging method by gas ionisation

    International Nuclear Information System (INIS)

    Eickel, R.; Rheude, A.

    1982-02-01

    The search for a substitute of the silver halide film has been intensified worldwide due to the shortage and price increase of silver metal. Gasionography could be an alternative to the wellknown silver film imaging techniques in roentgenology. Therefore the practical basis of the imaging process and the electrophoretic development was investigated. The technical realisation of this method was demonstrated for two different types of X-ray examen by developing a fully automatic chest changer and a mammography system that can be adapted to commercially available imaging stands. The image quality achieved with these apparatus was evaluated in comparison with conventional film techniques in the laboratory as well as in a clinical trial. (orig.) [de

  2. Effect of ionising radiation exposure on structure and permeability of epithelial junctions in rat ileum

    International Nuclear Information System (INIS)

    Lebrum, F.; Dublineau, I.; Grison, S.; Strup, C.; Griffiths, N.M.

    2002-01-01

    Exposure of the digestive tract to ionising radiation results in both morphological and functional alterations of the small intestine. However little is known about the effect of irradiation on the junctions playing a major role in the maintenance of epithelial barrier integrity. Thus the aim of this study was to investigate, in rat ileum, the effect of radiation exposure on the permeability of the epithelial barrier in parallel with the localization of certain inter- and intra-cellular proteins of tight and adherent junctions

  3. Beta-decay measurements of neutron-rich thallium, lead, and bismuth by means of resonant laser ionisation

    Science.gov (United States)

    Franchoo, S.; de Witte, H.; Andreyev, A. N.; Cederka¨Ll, J.; Dean, S.; de Smet, A.; Eeckhaudt, S.; Fedorov, D. V.; Fedosseev, V. N.; G´Rska, M.; Huber, G.; Huyse, M.; Janas, Z.; Ko¨Ster, U.; Kurcewicz, W.; Kurpeta, J.; Mayer, P.; Płchocki, A.; van de Vel, K.; van Duppen, P.; Weissman, L.; Isolde Collaboration

    2004-04-01

    Neutron-rich thallium, lead, and bismuth isotopes were investigated at the ISOLDE facility. After mass separation and resonant laser ionisation of the produced activity, new spectroscopic data were obtained for 215,218Bi and 215Pb. An attempt to reach heavy thallium had to be abandoned because of a strong francium component in the beam that gave rise to a neutron background through (α,n) reactions on the aluminium walls of the experimental chamber.

  4. 1962 : Bay City gas

    International Nuclear Information System (INIS)

    Anon.

    2008-01-01

    In 1962, a major natural gas export system from Alberta to San Francisco was brought online. The $300 million, 2,200 km Alberta and Southern system was expected to transport 584 million cubic feet daily in its first year of operation, more than one-third the total volume of gas sold by Canadian producers the previous year. The new gas export market also served to create more gas for the Canadian market because the incentive to serve a large export market also encouraged producers to explore for and develop more gas. The pipeline system started in the foothills belt 200 km northwest of Edmonton, and spanned through Idaho, Washington, Oregon and California. One month before its official opening, a gas line explosion occurred during pressure testing of a lateral line. The Alberta portion of the Alberta and Southern system was also used 2 decades later as a tie-in to the Alaska Highway Gas Pipeline project. Other key events in 1962 included approval of the Great Canadian Oil Sands Limited; the manufacture of the first rock drill bits in western Canada; production of 90 million cubic feet of natural gas from 12 wells in Quebec; and, an increase in oil production from the Soviet Union. 1 tab., 1 fig

  5. Calculated ionisation potentials determine the oxidation of vanillin precursors by lignin peroxidase.

    Science.gov (United States)

    ten Have, R; Rietjens, I M; Hartmans, S; Swarts, H J; Field, J A

    1998-07-03

    In view of the biocatalytic production of vanillin, this research focused on the lignin peroxidase (LiP) catalysed oxidation of naturally occurring phenolic derivatives: O-methyl ethers, O-acetyl esters, and O-glucosyl ethers. The ionisation potential (IP) of a series of model compounds was calculated and compared to their experimental conversion by LiP, defining a relative IP threshold of approximately 9.0 eV. Based on this threshold value only the O-acetyl esters and glucosides of isoeugenol and coniferyl alcohol would be potential LiP substrates. Both O-acetyl esters were tested and were shown to be converted to O-acetyl vanillin in molar yields of 51.8 and 2.3%, respectively.

  6. Integrated cross sections for the ionisation of atomic hydrogen by electron impact

    International Nuclear Information System (INIS)

    Konovalov, D.A.; McCarthy, I.E.

    1992-05-01

    Distorted-wave Born approximation (DWBA) calculations are reported for singly-differential and total cross sections for the electron impact ionisation for atomic hydrogen at 25, 40, 60, 100, 150 and 250 eV. The theory is compared with available experiments. At all the energies except 25 eV the theory predicts a lower singly-differential cross section for the low-energy side of the secondary-electron energies (<5 eV), compared to the only available absolute measurements of Shyn (1992). The DWBA calculation is in good agreement with the experiment at 25 eV but only if e-e post-collision interaction is included in the theory in some way. 23 refs., 2 figs

  7. Assessing the surroundings for effects of ionising radiation on the granting of permits, DOVIS A. Emissions to air and water

    CERN Document Server

    Blaauboer, R O

    2002-01-01

    In the Netherlands, as in most other countries, one generally needs a permit to produce (including the manufacture, processing, control and storage), to apply or to dispose of radioactive materials, or to use equipment that produces ionising radiation. This permit must be in accordance with the Nuclear Energy Act. Limits that are set for radioactive material can be found in the Decree on radiation protection ('Besluit stralings-bescherming') which has been in force since March 1, 2002. Along with the application for a permit, calculation results have to be submitted on the radiation dose that members of the public receive as a consequence of (possible) emissions of radioactive material (into the atmosphere or surface water) or as a consequence of external irradiation. Fairly rough estimates, based on simple rules, will often be satisfactory. These rules can be found in an annex of a Ministerial Order on the assessment of consequences of ionising radiation (mr-AGIS). However, in some cases this will not be ade...

  8. Nuclear and cytoplasmic signalling in the cellular response to ionising radiation

    International Nuclear Information System (INIS)

    Szumiel, Irena

    2001-01-01

    DNA is the universal primary target for ionising radiation; however, the cellular response is highly diversified not only by differential DNA repair ability. The monitoring system for the ionising radiation-inflicted DNA damage consists of 3 apparently independently acting enzymes which are activated by DNA breaks: two protein kinases, ATM (ataxia telangiectasia mutated) and DNA-PK (DNA-dependent protein kinase) and a poly(ADP-ribose) polymerase, PARP-1. These 3 enzymes are the source of alarm signals, which affect to various extents DNA repair, progression through the cell cycle and eventually the pathway to cell death. Their functions probably are partly overlapping. On the side of DNA repair their role consists in recruiting and/or activating the repair enzymes, as well as preventing illegitimate recombination of the damaged sites. A large part of the nuclear signalling pathway, including the integrating role of TP53 has been revealed. Two main signalling pathways start at the plasma membrane: the MAPK/ERK (mitogen and extracellular signal regulated protein kinase family) 'survival pathway' and the SAPK/JNK (stress-activated protein kinase/c-Jun N-terminal kinase) 'cell death pathway'. The balance between them is likely to determine the cell's fate. An additional important 'survival pathway' starts at the insulin-like growth factor type I receptor (IGF-IR), involves phosphoinositide- 3 kinase and Akt kinase and is targeted at inactivation of the pro-apoptotic BAD protein. Interestingly, over-expression of IGF-IR almost entirely abrogates the extreme radiation sensitivity of ataxia telangiectasia cells. When DNA break rejoining is impaired, the cell is unconditionally radiation sensitive. The fate of a repair-competent cell is determined by the time factor: the cell cycle arrest should be long enough to ensure the completion of repair. Incomplete repair or misrepair may be tolerated, when generation of the death signal is prevented. So, the character and timing

  9. Gas Modelling in the Disc of HD 163296

    Science.gov (United States)

    Tilling, I.; Woitke, P.; Meeus, G.; Mora, A.; Montesinos, B.; Riviere-Marichalar, P.; Eiroa, C.; Thi, W. -F.; Isella, A.; Roberge, A.; hide

    2011-01-01

    We present detailed model fits to observations of the disc around the Herbig Ae star HD 163296. This well-studied object has an age of approx. 4Myr, with evidence of a circumstellar disc extending out to approx. 540AU. We use the radiation thermo-chemical disc code ProDiMo to model the gas and dust in the circumstellar disc of HD 163296, and attempt to determine the disc properties by fitting to observational line and continuum data. These include new Herschel/PACS observations obtained as part of the open-time key program GASPS (Gas in Protoplanetary Systems), consisting of a detection of the [Oi] 63 m line and upper limits for several other far infrared lines. We complement this with continuum data and ground-based observations of the CO-12 3-2, 2-1 and CO-13 J=1-0 line transitions, as well as the H2 S(1) transition. We explore the effects of stellar ultraviolet variability and dust settling on the line emission, and on the derived disc properties. Our fitting efforts lead to derived gas/dust ratios in the range 9-100, depending on the assumptions made. We note that the line fluxes are sensitive in general to the degree of dust settling in the disc, with an increase in line flux for settled models. This is most pronounced in lines which are formed in the warm gas in the inner disc, but the low excitation molecular lines are also affected. This has serious implications for attempts to derive the disc gas mass from line observations. We derive fractional PAH abundances between 0.007 and 0.04 relative to ISM levels. Using a stellar and UV excess input spectrum based on a detailed analysis of observations, we find that the all observations are consistent with the previously assumed disc geometry

  10. High rate of destruction of molecular clouds by hot stars

    International Nuclear Information System (INIS)

    Heydari-Malayeri, M.; Lortet, M.C.; Deharveng, L.

    1980-01-01

    Tenorio-Tagle (1979) first proposed the idea of a third dynamical phase, the champagne phase, following the formation and expansion phases of an HII region. The champagne phase begins when the high pressure gas of an HII region formed inside a molecular cloud reaches the edge of the cloud and bursts into the lower pressure, low density, intercloud medium. One important implication of the model is the prediction of an enormous enhancement of the rate of erosion of the molecular cloud by the ionising radiation of hot stars, which begins as soon as the process of the decrease of the gas density between the star and the cloud is started. The proportion of hydrogen molecules eroded by ionising photons may reach about 10 -2 . The mass eroded may exceed the mass of the ionised gas in the case where the ionisation front reaching the edge of the cloud is of D-type. Additional mechanisms (for instance stellar winds), if at work, may even increase the efficiency of the mechanism. (Auth.)

  11. Gas distributor for fluidized bed coal gasifier

    Science.gov (United States)

    Worley, Arthur C.; Zboray, James A.

    1980-01-01

    A gas distributor for distributing high temperature reaction gases to a fluidized bed of coal particles in a coal gasification process. The distributor includes a pipe with a refractory reinforced lining and a plurality of openings in the lining through which gas is fed into the bed. These feed openings have an expanding tapered shape in the downstream or exhaust direction which aids in reducing the velocity of the gas jets as they enter the bed.

  12. Spectral radiance of strong lines in positive column mercury discharges with argon carrier gas

    International Nuclear Information System (INIS)

    Sansonetti, Craig J; Reader, Joseph

    2006-01-01

    The spectral radiance of the 185 and 254 nm lines in two positive column mercury discharge lamps was measured over a wide range of operating conditions. The lamps had internal diameters of 5 and 23 mm. Argon was used as a carrier gas. The lamps were operated with cold spot temperatures of 20, 40 and 60 0 C. At each of these temperatures, results were obtained for five currents ranging from 20 to 100 mA for the 5 mm lamp and from 200 to 1000 mA for the 23 mm lamp. For each current studied, results were determined for argon pressures ranging from 66.6 to 666 Pa (0.5 to 5.0 Torr) in the 5 mm lamp and 26.6 to 666 Pa (0.2 to 5.0 Torr) in the 23 mm lamp. An argon miniarc was used as the radiometric standard. By calibrating the spectral response of the optical system with a well-characterized mercury pencil lamp, results were obtained for 12 additional Hg lines from 289 to 579 nm. For the 23 mm lamp the electric field in the positive column was measured. For this lamp the radiated power as a percentage of input power was also determined. The results provide an experimental basis for validating computer models of Hg fluorescent lamp discharges

  13. Medical effects of low doses of ionising radiation

    International Nuclear Information System (INIS)

    Coggle, J.E.

    1990-01-01

    Ionising radiation is genotoxic and causes biological effects via a chain of events involving DNA strand breaks and 'multiply damaged sites' as critical lesions that lead to cell death. The acute health effects of radiation after doses of a few gray, are due to such cell death and consequent disturbance of cell population kinetics. Because of cellular repair and repopulation there is generally a threshold dose of about 1-2 Gy below which such severe effects are not inducible. However, more subtle, sub-lethal mutational DNA damage in somatic cells of the body and the germ cells of the ovary and testis cause the two major low dose health risks -cancer induction and genetic (heritable) effects. This paper discusses some of the epidemiological and experimental evidence regarding radiation genetic effects, carcinogenesis and CNS teratogenesis. It concludes that current risk estimates imply that about 3% of all cancers; 1% of genetic disorders and between 0% and 0.3% of severe mental subnormality in the UK is attributable to the ubiquitous background radiation. The health risks associated with the medical uses of radiation are smaller, whilst the nuclear industry causes perhaps 1% of the health detriment attributable to background doses. (author)

  14. Martian sub-surface ionising radiation: biosignatures and geology

    Directory of Open Access Journals (Sweden)

    J. M. Ward

    2007-07-01

    Full Text Available The surface of Mars, unshielded by thick atmosphere or global magnetic field, is exposed to high levels of cosmic radiation. This ionising radiation field is deleterious to the survival of dormant cells or spores and the persistence of molecular biomarkers in the subsurface, and so its characterisation is of prime astrobiological interest. Here, we present modelling results of the absorbed radiation dose as a function of depth through the Martian subsurface, suitable for calculation of biomarker persistence. A second major implementation of this dose accumulation rate data is in application of the optically stimulated luminescence technique for dating Martian sediments.

    We present calculations of the dose-depth profile in the Martian subsurface for various scenarios: variations of surface composition (dry regolith, ice, layered permafrost, solar minimum and maximum conditions, locations of different elevation (Olympus Mons, Hellas basin, datum altitude, and increasing atmospheric thickness over geological history. We also model the changing composition of the subsurface radiation field with depth compared between Martian locations with different shielding material, determine the relative dose contributions from primaries of different energies, and discuss particle deflection by the crustal magnetic fields.

  15. Moving droplets : The measurement of contact lines

    NARCIS (Netherlands)

    Poelma, C.; Franken, M.J.Z.; Kim, H.; Westerweel, J.

    2014-01-01

    Contact lines are the locations where a gas, liquid and a solid meet. From everyday experience we know that such contact lines can be mobile, for example in the case of a water droplet sliding over a glass surface. However, the continuum description of the flow towards or away from a contact line

  16. ALMA MULTI-LINE IMAGING OF THE NEARBY STARBURST NGC 253

    Energy Technology Data Exchange (ETDEWEB)

    Meier, David S. [New Mexico Institute of Mining and Technology, 801 Leroy Place, Socorro, NM 87801 (United States); Walter, Fabian; Zschaechner, Laura K. [Max-Planck Institut für Astronomie, Königstuhl 17, D-69117 Heidelberg (Germany); Bolatto, Alberto D.; Veilleux, Sylvain; Warren, Steven R. [Department of Astronomy and Joint Space-Science Institute, University of Maryland, College Park, MD 20742 (United States); Leroy, Adam K. [National Radio Astronomy Observatory, 520 Edgemont Road, Charlottesville, VA 22903 (United States); Ott, Jürgen [National Radio Astronomy Observatory, Pete V. Domenici Array Science Center, P.O. Box O, Socorro, NM 87801 (United States); Rosolowsky, Erik [Department of Physics, University of Alberta, Edmonton, AB T6G 2E1 (Canada); Weiß, Axel [Max Planck Institut für Radioastronomie, Auf dem Hügel 69, D-53121 Bonn (Germany); Zwaan, Martin A., E-mail: dmeier@nmt.edu [European Southern Observatory, Karl-Schwarzschild-Str. 2, D-85748 Garching bei München (Germany)

    2015-03-01

    We present spatially resolved (∼50 pc) imaging of molecular gas species in the central kiloparsec of the nearby starburst galaxy NGC 253, based on observations taken with the Atacama Large Millimeter/submillimeter Array. A total of 50 molecular lines are detected over a 13 GHz bandwidth imaged in the 3 mm band. Unambiguous identifications are assigned for 27 lines. Based on the measured high CO/C{sup 17}O isotopic line ratio (≳350), we show that {sup 12}CO(1-0) has moderate optical depths. A comparison of the HCN and HCO{sup +} with their {sup 13}C-substituted isotopologues shows that the HCN(1-0) and HCO{sup +}(1-0) lines have optical depths at least comparable to CO(1-0). H{sup 13}CN/H{sup 13}CO{sup +} (and H{sup 13}CN/HN{sup 13}C) line ratios provide tighter constraints on dense gas properties in this starburst. SiO has elevated abundances across the nucleus. HNCO has the most distinctive morphology of all the bright lines, with its global luminosity dominated by the outer parts of the central region. The dramatic variation seen in the HNCO/SiO line ratio suggests that some of the chemical signatures of shocked gas are being erased in the presence of dominating central radiation fields (traced by C{sub 2}H and CN). High density molecular gas tracers (including HCN, HCO{sup +}, and CN) are detected at the base of the molecular outflow. We also detect hydrogen β recombination lines that, like their α counterparts, show compact, centrally peaked morphologies, distinct from the molecular gas tracers. A number of sulfur based species are mapped (CS, SO, NS, C{sub 2}S, H{sub 2}CS, and CH{sub 3}SH) and have morphologies similar to SiO.

  17. A gas proportional scintillation counter for use in large area detector systems without photomultipliers

    International Nuclear Information System (INIS)

    Baruch, J.E.F.; Brooke, G.; Kellerman, E.W.; Bateman, J.E.; Connolly, J.F.

    1979-01-01

    The properties of a prototype gas proportional scintillation (GPS) detector module are described. The module (25X25X14cm 3 ) is intended to form the basic unit of large area (up to approximately 100 m 2 ) calorimetric cosmic ray burst detector. Ionisation from particle tracks in the module is collected onto a point electrode where the GPS signal is generated. A concave mirror focusses this point source onto the end of a fibre optic light guide. In the proposed large area detector these fibres are brought together onto a low light level TV camera which performs the readout. The prototype module has demonstrated an adequate light output for the detection of single muons by such a readout system and also permitted the investigation of the main operating parameters (gas mixture, EHT, pressure, etc) and operational requirements such as proportionality and long term stability. (Auth.)

  18. Dopant-assisted negative photoionization Ion mobility spectrometry coupled with on-line cooling inlet for real-time monitoring H2S concentration in sewer gas.

    Science.gov (United States)

    Peng, Liying; Jiang, Dandan; Wang, Zhenxin; Hua, Lei; Li, Haiyang

    2016-06-01

    Malodorous hydrogen sulfide (H2S) gas often exists in the sewer system and associates with the problems of releasing the dangerous odor to the atmosphere and causing sewer pipe to be corroded. A simple method is in demand for real-time measuring H2S level in the sewer gas. In this paper, an innovated method based on dopant-assisted negative photoionization ion mobility spectrometry (DANP-IMS) with on-line semiconductor cooling inlet was put forward and successfully applied for the real-time measurement of H2S in sewer gas. The influence of moisture was effectively reduced via an on-line cooling method and a non-equilibrium dilution with drift gas. The limits of quantitation for the H2S in ≥60% relative humidity air could be obtained at ≤79.0ng L(-1) with linear ranges of 129-2064ng L(-1). The H2S concentration in a sewer manhole was successfully determined while its product ions were identified by an ion-mobility time-of-fight mass spectrometry. Finally, the correlation between sewer H2S concentration and the daily routines and habits of residents was investigated through hourly or real-time monitoring the variation of sewer H2S in manholes, indicating the power of this DANP-IMS method in assessing the H2S concentration in sewer system. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Conception and realization of optical diagnosis to characterize gas puffs in Z-Pinch experiments. Comparison between experiment and computation. Study of a new nozzle

    International Nuclear Information System (INIS)

    Barnier, J.N.

    1998-01-01

    The CEA develops research programs on plasma. A good way to generate such X-rays sources, is to realize Z-pinch experiments, so to realize the radial implosion on its axis of a conducting cylinder in a very high current. The AMBIORIX machine, allowing such experiments, calls for necessitates the use of gaseous conductors. The gas puff, coming from the nozzle, is ionised by a 2 MA current. The aim of this thesis is the characterisation of the gas source before the current impulse. For this purpose many optic diagnostics have been tested. Interferometric measures allow the gas profile density measurement. Various gas have been studied: neon, argon, helium and aluminium. For the aluminium, the resonant interferometric imagery method has been used. A new nozzle with an innovative injection technic, has been designed, characterized and tested in Z-pinch configuration. Finally measures of light diffusion (Rayleigh) have been realised to show dust in the gas. (A.L.B.)

  20. Preliminary studies of using preheated carrier gas for on-line membrane extraction of semivolatile organic compounds.

    Science.gov (United States)

    Liu, Xinyu; Pawliszyn, Janusz

    2007-04-01

    In this paper, we present results for the on-line determination of semivolatile organic compounds (SVOCs) in air using membrane extraction with a sorbent interface-ion mobility spectrometry (MESI-IMS) system with a preheated carrier (stripping) gas. The mechanism of the mass transfer of SVOCs across a membrane was initially studied. In comparison with the extraction of volatile analytes, the mass transfer resistance that originated from the slow desorption from the internal membrane surface during the SVOC extraction processes should be taken into account. A preheated carrier gas system was therefore built to facilitate desorption of analytes from the internal membrane surface. With the benefit of a temperature gradient existing between the internal and external membrane surfaces, an increase in the desorption rate of a specific analyte at the internal surface and the diffusion coefficient within the membrane could be achieved while avoiding a decrease of the distribution constant on the external membrane interface. This technique improved both the extraction rate and response times of the MESI-IMS system for the analysis of SVOCs. Finally, the MESI-IMS system was shown to be capable of on-site measurement by monitoring selected polynuclear aromatic hydrocarbons emitted from cigarette smoke.

  1. Fault location method for unexposed gas trunk line insulation at stray current constant effect area

    Science.gov (United States)

    Tsenev, A. N.; Nosov, V. V.; Akimova, E. V.

    2017-10-01

    For the purpose of gas trunk lines safe operation, two types of pipe wall metal anticorrosion protection are generally used - the passive (insulation coating) protection and the active (electrochemical) protection. In the process of a pipeline long-term operation, its insulation is subject to wear and damage. Electrochemical protection means of a certain potential value prevent metal dissolution in the soil. When insulation wear and tear attains a level of insufficiency of the protection potential value, the insulating coating needs repair which is a labor-consuming procedure. To reduce the risk of such situation, it is necessary to make inspection rounds to monitor the condition of pipe insulation. A method for pipeline insulation coating unexposed fault location based on Pearson method is considered, wherein a working cathodic protection station signal of 100 Hz frequency is used, which makes installation of a generator unnecessary, and also a specific generator signal of 1 kHz frequency is used at high noise immunity and sensitivity of the instrument complex. This method enables detection and sizing of unexposed pipeline defects within the zones of earth current permanent action. High noise immunity of selective indicators allows for operation in proximity to 110 kV, 220 kV, and 500 kV power transmission lines in action.

  2. Instrument for continuous supervision of the radioactivity of CO2 coolant in piles - DCCA -CO2 (1960)

    International Nuclear Information System (INIS)

    Fitoussi, L.

    1960-01-01

    This paper describes an apparatus for continuous measurement of CO 2 activity, which can be used on piles cooled by circulation of gas. The first part is devoted mainly to describing the apparatus used and the character of the radioactivity and thermodynamic measurements carried out, and giving the general characteristics of the gas circuit required if the instrument is to be suitably gas-tight. In the second part theoretical calculations are given, particularly on the determination of the ionisation current in an ionisation chamber with circulating gas. Several parameters enter into this determination, such as the mean path of β particles in the ionisation chamber, the linear number of ion pairs formed in the gas by these β particles as a function of their energy, the temperature and pressure of the gas in the ionisation chamber. This part also evaluates the sensitivity areas of the apparatus for measuring the concentrations of radioactive gases such as argon-41 and fission gases from uranium-235 in the CO 2 coolant. In the last part are described the results of measurements performed with such an apparatus on the pile EL2, the special investigations carried out on the CO 2 coolant of this pile, and the information gained during normal operation and during accidents. The DCCA - CO 2 which has just been put in operation at G2 is briefly presented. In the conclusion the possibilities offered by this apparatus are underlined. (author) [fr

  3. On-line sample treatment - Capillary gas chromatography

    NARCIS (Netherlands)

    Goosens, EC; de Jong, D; de Jong, GJ; Brinkman, UAT

    Sample pretreatment is often the bottleneck of a trace level analytical procedure. In order to increase performance, increasing attention is therefore being devoted to combining sample pretreatment on-line with the separation technique that has to be used. In the present review, a variety of

  4. Measurements of ion mobility in argon and neon based gas mixtures

    CERN Document Server

    INSPIRE-00507268

    2017-01-01

    As gaseous detectors are operated at high rates of primary ionisation, ions created in the detector have a considerable impact on the performance of the detector. The upgraded ALICE Time Projection Chamber (TPC) will operate during LHC Run$\\,3$ with a substantial space charge density of positive ions in the drift volume. In order to properly simulate such space charges, knowledge of the ion mobility $K$ is necessary. To this end, a small gaseous detector was constructed and the ion mobility of various gas mixtures was measured. To validate the corresponding signal analysis, simulations were performed. Results are shown for several argon and neon based mixtures with different $\\textrm{CO}_2$ fractions. A decrease of $K$ was measured for increasing water content.

  5. Superconducting cable cooling system by helium gas at two pressures

    International Nuclear Information System (INIS)

    Dean, J.W.

    1977-01-01

    Thermally contacting, oppositely streaming, cryogenic fluid streams in the same enclosure in a closed cycle changes the fluid from a cool high pressure helium gas to a cooler reduced pressure helium gas in an expander so as to be at different temperature ranges and pressures respectively in go and return legs that are in thermal contact with each other and in thermal contact with a longitudinally extending superconducting transmission line enclosed in the same cable enclosure that insulates the line from the ambient at a temperature T 1 . By first circulating the fluid from a refrigerator at one end of the line as a cool gas at a temperature range T 2 to T 3 in the go leg, then circulating the gas through an expander at the other end of the line where the gas becomes a cooler gas at a reduced pressure and at a reduced temperature T 4 and finally by circulating the cooler gas back again to the refrigerator in a return leg at a temperature range T 4 to T 5 , while in thermal contact with the gas in the go leg, and in the same enclosure therewith for compression into a higher pressure gas at T 2 in a closed cycle, where T 2 greater than T 3 and T 5 greater than T 4 , the fluid leaves the enclosure in the go leg as a gas at its coldest point in the go leg, and the temperature distribution is such that the line temperature decreases along its length from the refrigerator due to the cooling from the gas in the return leg

  6. The gas-phase on-line production of phosphoryl halides, Pox sub 3 and their identification by infrared spectroscopy

    International Nuclear Information System (INIS)

    Allaf, A.W.

    1999-01-01

    A new route has been devised, leading to the production of Pox sub 3 molecules where X=F, Br and I by an on-line process using phosphoryl chloride, POCI sub 3 as a starting material passed over heated sodium fluoride, NaF, potassium bromide, KBr and potassium iodide, K1 at 535 Centigrade, 690 Centigrade and 480 Centigrade, respectively. The low resolution gas-phase fourier transform infrared spectra reported for the first time showed strong bands centered at 1411.6, 1322.9, 1300.8 and 1285 cm sup - 1, assigned to EPSILON sub 1 (a sub 1), the O = P stretching fundamental of POF sub 3 , POCI sub 3 , POBr sub 3 and POI sub 3 , respectively. Attempts were made to prepare POCI sub 2 and POBr sub 2 , by an on-line process using POCI sub 3 again but passed over heated sodium and potassium bromide for POCI sub 2 and POBr sub 2. (author)

  7. Millimeter-wave Line Ratios and Sub-beam Volume Density Distributions

    Energy Technology Data Exchange (ETDEWEB)

    Leroy, Adam K.; Gallagher, Molly [Department of Astronomy, The Ohio State University, 140 West 18th Avenue, Columbus, OH 43210 (United States); Usero, Antonio [Observatorio Astronmico Nacional (IGN), C/Alfonso XII, 3, E-28014 Madrid (Spain); Schruba, Andreas [Max-Planck-Institut für extraterrestrische Physik, Giessenbachstraße 1, D-85748 Garching (Germany); Bigiel, Frank [Institute für theoretische Astrophysik, Zentrum für Astronomie der Universität Heidelberg, Albert-Ueberle Str. 2, D-69120 Heidelberg (Germany); Kruijssen, J. M. Diederik; Schinnerer, Eva [Astronomisches Rechen-Institut, Zentrum für Astronomie der Universität Heidelberg, Mönchhofstraße 12-14, D-69120 Heidelberg (Germany); Kepley, Amanda [National Radio Astronomy Observatory, 520 Edgemont Road, Charlottesville, VA 22903 (United States); Blanc, Guillermo A. [Departamento de Astronomía, Universidad de Chile, Casilla 36-D, Santiago (Chile); Bolatto, Alberto D. [Department of Astronomy, Laboratory for Millimeter-wave Astronomy, and Joint Space Institute, University of Maryland, College Park, MD 20742 (United States); Cormier, Diane; Jiménez-Donaire, Maria J. [Max Planck Institute für Astronomie, Königstuhl 17, D-69117, Heidelberg (Germany); Hughes, Annie [CNRS, IRAP, 9 av. du Colonel Roche, BP 44346, F-31028 Toulouse cedex 4 (France); Rosolowsky, Erik [Department of Physics, University of Alberta, Edmonton, AB (Canada)

    2017-02-01

    We explore the use of mm-wave emission line ratios to trace molecular gas density when observations integrate over a wide range of volume densities within a single telescope beam. For observations targeting external galaxies, this case is unavoidable. Using a framework similar to that of Krumholz and Thompson, we model emission for a set of common extragalactic lines from lognormal and power law density distributions. We consider the median density of gas that produces emission and the ability to predict density variations from observed line ratios. We emphasize line ratio variations because these do not require us to know the absolute abundance of our tracers. Patterns of line ratio variations have the potential to illuminate the high-end shape of the density distribution, and to capture changes in the dense gas fraction and median volume density. Our results with and without a high-density power law tail differ appreciably; we highlight better knowledge of the probability density function (PDF) shape as an important area. We also show the implications of sub-beam density distributions for isotopologue studies targeting dense gas tracers. Differential excitation often implies a significant correction to the naive case. We provide tabulated versions of many of our results, which can be used to interpret changes in mm-wave line ratios in terms of adjustments to the underlying density distributions.

  8. Design innovations in neutron and gamma detectors

    International Nuclear Information System (INIS)

    Prasad, K.R.

    2003-01-01

    Neutron and gamma radiation needs to be monitored in most nuclear installations since it is highly penetrating. On-line monitoring of these radiations is very important for the safe and controlled operation of nuclear reactors, accelerators etc. Several design innovations have been carried out on gas ionisation detectors such as boron-lined proportional counters and ion chambers, fission detectors, gamma ion chambers as well as self-powered detectors. The use of additional structures within boron-lined detectors has enhanced their neutron sensitivity without a corresponding increase in the unwanted gamma sensitivity. The neutron sensitivity of fission counters can be enhanced by designing them as transmission line devices. Ion chambers with two and six pairs of electrodes have been developed for monitoring pulsed x-ray background at accelerator areas. Ion chambers have been employed at gamma fields up to 80 kR/h by deriving the exposure levels on-line using microcontroller devices programmed on the basis of theoretical and empirical formulas. The use of gas electron multiplier foils is proposed for charge multiplication in ion chambers. Self-powered detectors with new emitter materials like Hi, Ni and Inconel have been developed. (author)

  9. Draft guidance notes for the protection of persons against ionising radiations arising from veterinary use

    International Nuclear Information System (INIS)

    1983-01-01

    These guidance notes have been prepared for those who use ionising radiation for diagnostic purposes in veterinary practice, either in private practices or in larger institutions. Ancillary activities such as the testing and calibration of equipment are also covered by these notes so far as they are carried out on the same premises. The guidance notes indicate procedures for the protection of all persons who may be exposed as a result of these practices, that is to say all employed and self-employed persons, apprentices and students, and members of the public. (author)

  10. Using the van der Waals broadening of spectral atomic lines to measure the gas temperature of an argon-helium microwave plasma at atmospheric pressure

    International Nuclear Information System (INIS)

    Munoz, J.; Dimitrijevic, M.S.; Yubero, C.; Calzada, M.D.

    2009-01-01

    The applications of plasmas generated with gas mixtures have become increasingly common in different scientific and technological fields. In order to understand the advantages of these discharges, for instance in chemical analysis, it is necessary to know the gas temperature (T g , kinetic energy of the heavy particles) since it has a great influence on the atomization reactions of the molecules located in the discharge, along with the dependence of the reaction rate on this parameter. The ro-vibrational emission spectra of the molecular species are usually used to measure the gas temperature of a discharge at atmospheric pressure although under some experimental conditions, these are difficult to detect. In such cases, the gas temperature can be determined from the van der Waals broadening of the emitted atomic spectral lines related to this parameter. The method proposed is based on the van der Waals broadening taking into account two perturbers

  11. Simultaneous derivatisation and preconcentration of parabens in food and other matrices by isobutyl chloroformate and dispersive liquid-liquid microextraction followed by gas chromatographic analysis.

    Science.gov (United States)

    Jain, Rajeev; Mudiam, Mohana Krishna Reddy; Chauhan, Abhishek; Ch, Ratnasekhar; Murthy, R C; Khan, Haider A

    2013-11-01

    A simple, rapid and economical method has been proposed for the quantitative determination of parabens (methyl, ethyl, propyl and butyl paraben) in different samples (food, cosmetics and water) based on isobutyl chloroformate (IBCF) derivatisation and preconcentration using dispersive liquid-liquid microextraction in single step. Under optimum conditions, solid samples were extracted with ethanol (disperser solvent) and 200 μL of this extract along with 50 μL of chloroform (extraction solvent) and 10 μL of IBCF was rapidly injected into 2 mL of ultra-pure water containing 150 μL of pyridine to induce formation of a cloudy state. After centrifugation, 1 μL of the sedimented phase was analysed using gas chromatograph-flame ionisation detector (GC-FID) and the peaks were confirmed using gas chromatograph-positive chemical ionisation-mass spectrometer (GC-PCI-MS). Method was found to be linear over the range of 0.1-10 μg mL(-1) with square of correlation coefficient (R(2)) in the range of 0.9913-0.9992. Limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.029-0.102 μg mL(-1) and 0.095-0.336 μg mL(-1) with a signal to noise ratio of 3:1 and 10:1, respectively. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Brome isotope selective control of CF3Br molecule clustering by IR laser radiation in gas-dynamic expansion of CF3Br - Ar mixture

    Science.gov (United States)

    Apatin, V. M.; Lokhman, V. N.; Makarov, G. N.; Ogurok, N.-D. D.; Ryabov, E. A.

    2018-02-01

    We report the results of research on the experimental control of CF3Br molecule clustering under gas-dynamic expansion of the CF3Br - Ar mixture at a nozzle exit by using IR laser radiation. A cw CO2 laser is used for exciting molecules and clusters in the beam and a time-of-flight mass-spectrometer with laser UV ionisation of particles for their detection. The parameters of the gas above the nozzle are determined (compositions and pressure) at which intensive molecule clustering occurs. It is found that in the case of the CF3Br gas without carrier when the pressure P0 above the nozzle does not exceed 4 atm, molecular clusters actually are not generated in the beam. If the gas mixture of CF3Br with argon is used at a pressure ratio 1 : N, where N >= 3, and the total pressure above the nozzle is P0 >= 2 atm, then there occurs molecule clustering. We study the dependences of the efficiency of suppressing the molecule clustering on parameters of the exciting pulse, gas parameters above the nozzle, and on a distance of the molecule irradiation zone from the nozzle exit section. It is shown that in the case of resonant vibrational excitation of gas-dynamically cooled CF3Br molecules at the nozzle exit one can realise isotope-selective suppression of molecule clustering with respect to bromine isotopes. With the CF3Br - Ar mixtures having the pressure ratio 1 : 3 and 1 : 15, the enrichment factors obtained with respect to bromine isotopes are kenr ≈ 1.05 ± 0.005 and kenr ≈ 1.06 ± 0.007, respectively, under jet irradiation by laser emission in the 9R(30) line (1084.635 cm-1). The results obtained let us assume that this method can be used to control clustering of molecules comprising heavy element isotopes, which have a small isotopic shift in IR absorption spectra.

  13. The Swedish radiation protection institute's regulations on general obligations in medical and dental practices using ionising radiation; issued on April 28, 2000

    International Nuclear Information System (INIS)

    2000-04-01

    These regulations are applicable to medical and dental practices with ionising radiation used for medical exposures. The regulations are also applicable to exposures of persons who knowingly and willingly, other than as part of their occupation, support and comfort patients undergoing medical exposure

  14. Education and training issues in individual monitoring of ionising radiation

    International Nuclear Information System (INIS)

    Dimitriou, P.; Kamenopoulou, V.

    2011-01-01

    The present article deals with the education and training (E and T) issues of individual monitoring (IM) of ionising radiation, based on the requirements provided by the Basic Safety Standards EURATOM Directive and the European Commission Technical Recommendations for IM of external radiation. The structure and the objectives of E and T programmes addressed to the staff of dosimetry services, in order to allow the recognition and ensure the continuity of expertise are discussed. The necessity for the establishment of a national strategy for building competence in IM through information, education, training and retraining programmes, addressed to the individually monitored personnel is underlined. The train the trainers' concept is recognised as being an important tool for optimising resources and transferring the skills necessary for building competence. The conditions under which an efficient train the trainers' approach can be established are discussed. Examples of curricula concerning the key persons involved in the provision of E and T in occupational radiation protection are also given. (authors)

  15. Review of retrospective dosimetry techniques for external ionising radiation exposures

    International Nuclear Information System (INIS)

    Ainsbury, E. A.; Bakhanova, E.; Barquinero, J. F.; Brai, M.; Chumak, V.; Correcher, V.; Darroudi, F.; Fattibene, P.; Gruel, G.; Guclu, I.; Horn, S.; Jaworska, A.; Kulka, U.; Lindholm, C.; Lloyd, D.; Longo, A.; Marrale, M.; Monteiro Gil, O.; Oestreicher, U.; Pajic, J.; Rakic, B.; Romm, H.; Trompier, F.; Veronese, I.; Voisin, P.; Vral, A.; Whitehouse, C. A.; Wieser, A.; Woda, C.; Wojcik, A.; Rothkamm, K.

    2011-01-01

    The current focus on networking and mutual assistance in the management of radiation accidents or incidents has demonstrated the importance of a joined-up approach in physical and biological dosimetry. To this end, the European Radiation Dosimetry Working Group 10 on 'Retrospective Dosimetry' has been set up by individuals from a wide range of disciplines across Europe. Here, established and emerging dosimetry methods are reviewed, which can be used immediately and retrospectively following external ionising radiation exposure. Endpoints and assays include dicentrics, translocations, premature chromosome condensation, micronuclei, somatic mutations, gene expression, electron paramagnetic resonance, thermoluminescence, optically stimulated luminescence, neutron activation, haematology, protein biomarkers and analytical dose reconstruction. Individual characteristics of these techniques, their limitations and potential for further development are reviewed, and their usefulness in specific exposure scenarios is discussed. Whilst no single technique fulfils the criteria of an ideal dosemeter, an integrated approach using multiple techniques tailored to the exposure scenario can cover most requirements. (authors)

  16. Detection and on-line prediction of leak magnitude in a gas pipeline using an acoustic method and neural network data processing

    Directory of Open Access Journals (Sweden)

    R. B. Santos

    2014-03-01

    Full Text Available Considering the importance of monitoring pipeline systems, this work presents the development of a technique to detect gas leakage in pipelines, based on an acoustic method, and on-line prediction of leak magnitude using artificial neural networks. On-line audible noises generated by leakage were obtained with a microphone installed in a 60 m long pipeline. The sound noises were decomposed into sounds of different frequencies: 1 kHz, 5 kHz and 9 kHz. The dynamics of these noises in time were used as input to the neural model in order to determine the occurrence and the leak magnitude. The results indicated the great potential of the technique and of the developed neural network models. For all on-line tests, the models showed 100% accuracy in leak detection, except for a small orifice (1 mm under 4 kgf/cm² of nominal pressure. Similarly, the neural network models could adequately predict the magnitude of the leakages.

  17. Natural gas is more than gas power plants

    International Nuclear Information System (INIS)

    Lind, Oddvar

    2000-01-01

    Through the Statpipe gas line at Karmoey, Norway supplies 20% of the natural gas on the European market. The pipeline is 'leaking' a little bit of gas to the local communities at Karmoey and Haugesund. These communities have replaced 65% of their oil consumption with natural gas, which is a fine contribution to a better environment. The supplier of the natural gas, Gasnor ASA in this case, claims an energy efficiency of 90% at the end user because the gas burns directly and the loss in the pipeline is minimal. The efficiency of natural gas utilisation is twice that of the planned gas power stations in West-Norway, subtracting the losses in the electrical network. Gasnor ASA competes with oil suppliers and, if necessary, with electric utilities. The county hospital at Haugesund is quoted as an example. The hospital has two large boilers with dual fuel burners. They have been using natural gas since 1998 because it was worth while both economically and environmentally. The use of natural gas in the transport sector would be very important, but the necessary infrastructure is very little developed. For instance, five diesel-powered ferries on the Boknafjord emit as much NOx as the planned gas power plant at Kaarstoe

  18. The bipolar jet of the symbiotic star R Aquarii: A study of its morphology using the high-resolution HST WFC3/UVIS camera

    Science.gov (United States)

    Melnikov, Stanislav; Stute, Matthias; Eislöffel, Jochen

    2018-04-01

    Context. R Aqr is a symbiotic binary system consisting of a Mira variable with a pulsation period of 387 days and a hot companion which is presumably a white dwarf with an accretion disk. This binary system is the source of a prominent bipolar gaseous outflow. Aims: We use high spatial resolution and sensitive images from the Hubble Space Telescope (HST) to identify and investigate the different structural components that form the complex morphology of the R Aqr jet. Methods: We present new high-resolution HST WFC3/UVIS narrow-band images of the R Aqr jet obtained in 2013/14 using the [OIII]λ5007, [OI]λ6300, [NII]λ6583, and Hα emission lines. These images also allow us to produce detailed maps of the jet flow in several line ratios such as [OIII]λ5007/[OI]λ6300 and [NII]λ6583/[OI]λ6300 which are sensitive to the outflow temperature and its hydrogen ionisation fraction. The new emission maps together with archival HST data are used to derive and analyse the proper motion of prominent emitting features which can be traced over 20 years with the HST observations. Results: The images reveal the fine gas structure of the jet out to distances of a few tens of arcseconds from the central region, as well as in the innermost region, within a few arcseconds around the stellar source. They reveal for the first time the straight, highly collimated jet component which can be traced to up to 900 AU in the NE direction. Images in [OIII]λ5007, [OI]λ6300, and [NII]λ6583 clearly show a helical pattern in the jet beams which may derive from the small-scale precession of the jet. The highly collimated jet is accompanied by a wide opening angle outflow which is filled by low excitation gas. The position angles of the jet structures as well as their opening angles are calculated. Our measurements of the proper motions of some prominent emission knots confirm the scenario of gas acceleration during the propagation of the outflow. Finally, we produce several detailed line ratio

  19. Exhaust gas processing facility

    International Nuclear Information System (INIS)

    Terada, Shin-ichi.

    1995-01-01

    The facility of the present invention comprises a radioactive liquid storage vessel, an exhaust gas dehumidifying device for dehumidifying gases exhausted from the vessel and an exhaust gas processing device for reducing radioactive materials in the exhaust gases. A purified gas line is disposed to the radioactive liquid storage vessel for purging exhaust gases generated from the radioactive liquid, then dehumidified and condensed liquid is recovered, and exhaust gases are discharged through an exhaust gas pipe disposed downstream of the exhaust gas processing device. With such procedures, the scale of the exhaust gas processing facility can be reduced and exhaust gases can be processed efficiently. (T.M.)

  20. Feed gas contaminant control in ion transport membrane systems

    Science.gov (United States)

    Carolan, Michael Francis [Allentown, PA; Minford, Eric [Laurys Station, PA; Waldron, William Emil [Whitehall, PA

    2009-07-07

    Ion transport membrane oxidation system comprising an enclosure having an interior and an interior surface, inlet piping having an internal surface and adapted to introduce a heated feed gas into the interior of the enclosure, and outlet piping adapted to withdraw a product gas from the interior of the enclosure; one or more planar ion transport membrane modules disposed in the interior of the enclosure, each membrane module comprising mixed metal oxide material; and a preheater adapted to heat a feed gas to provide the heated feed gas to the inlet piping, wherein the preheater comprises an interior surface. Any of the interior surfaces of the enclosure, the inlet piping, and the preheater may be lined with a copper-containing metal lining. Alternatively, any of the interior surfaces of the inlet piping and the preheater may be lined with a copper-containing metal lining and the enclosure may comprise copper.