WorldWideScience

Sample records for line communication plc

  1. Power Line Communication (PLC) in Space - Current Status and Outlook

    Wolf, J.

    2012-05-01

    The Power Line Communication (PLC) technology as known from various terrestrial applications, e.g. in building automation, in the automotive sector and on aircraft, appears to be a promising technology for the use on spacecraft. Starting from a critical overview on existing terrestrial PLC applications with their pros and cons, the paper gives a motivation for the introduction of the PLC technology on spacecraft, discusses the potential areas where it can be applied and is highlighting the potential problem areas. A short overview of on-going ESA PLC activities is provided and an outlook is given.

  2. Performance analysis of the PLC (Power Line Communication) in medium voltage electrical networks; Analise de desempenho de sistemas PLC em redes eletricas de media tensao

    Mota, A.A.; Paleta, R. [Pontificia Universidade Catolica de Campinas (PUC-Campinas), SP (Brazil)], E-mail: amota@puc-campinas.edu.br; Mota, L.T.M.; Ricardo, R.A. [Indelmatec Engenharia, Campinas, SP (Brazil)], E-mail: mota@indelmatec.com.br

    2009-07-01

    Nowadays, the information access in communication networks is widely explored due to the increase of Internet users. In this context, the PLC (Power Line Communication) technology is an alternative for data transmission. This technology is based on the usage of transmission/distribution power lines for data transmission. However there are some problems related to the usage of this technology: adequate data transmission rates and generation of acceptable levels of electromagnetic interference (EMI). This work had the objective of studying the performance of PLC systems in medium voltage electrical networks, through the assess of data transmission rates and the generated EMI. Tests were carried out in a test field that corresponded to a medium voltage electrical network and the obtained results show that, under some circumstances, the PLC system does not reach the existent technical recommendations. (author)

  3. Fundamentación de la pertinencia y factibilidad de la aplicación domótica mediante la tecnología Power Line Communications PLC para redes domésticas en el Ecuador.

    Suárez Ramos, Diego Fernando

    2015-01-01

    En el presente trabajo se fundamenta la pertinencia y factibilidad de la aplicación domótica mediante la tecnología Power Line Communications PLC, para redes domésticas en el Ecuador. Demostrando que es posible utilizar esta tecnología en los hogares ecuatorianos como una alternativa en los sistemas domóticos existentes. Se presenta como ejemplo diseño para el control de un sistema de iluminación, integrándolo junto con un panel domótico en un domicilio la red eléctric existente.

  4. Power line communications theory and applications for narrowband and broadband communications over power lines

    Ferreira, Hendrik C; Newbury, John; Swart, Theo G

    2010-01-01

    Power Line Communications (PLC) is a promising emerging technology, which has attracted much attention due to the wide availability of power distribution lines. This book provides a thorough introduction to the use of power lines for communication purposes, ranging from channel characterization, communications on the physical layer and electromagnetic interference, through to protocols, networks, standards and up to systems and implementations. With contributions from many of the most prominent international PLC experts from academia and industry, Power Line Communications brings togeth

  5. Trend on High-speed Power Line Communication Technology

    Ogawa, Osamu

    High-speed power line communication (PLC) is useful technology to easily build the communication networks, because construction of new infrastructure is not necessary. In Europe and America, PLC has been used for broadband networks since the beginning of 21th century. In Japan, high-speed PLC was deregulated only indoor usage in 2006. Afterward it has been widely used for home area network, LAN in hotels and school buildings and so on. And recently, PLC is greatly concerned as communication technology for smart grid network. In this paper, the author surveys the high-speed PLC technology and its current status.

  6. Realization of PLC to the Variable Frequency Speed Regulation System of Mine Local Ventilator based on RS-485 Communication

    Ma, Kai; Li, Jian; Yun, Yichong

    2018-03-01

    The article first introduces the merits of serial communication in the PLC to the variable frequency speed regulation system of mine local ventilator, and then sets up a hardware application development platform of PLC and inverter based on RS-485 communication technology, next presents communication initialization of the PLC and Inverter. Finally according to the control requirements, PLC send run operation & monitoring instruction to Inverter, realizes the serial communication control between the PLC and Inverter.

  7. Frequency domain based LS channel estimation in OFDM based Power line communications

    Bogdanović, Mario

    2015-01-01

    This paper is focused on low voltage power line communication (PLC) realization with an emphasis on channel estimation techniques. The Orthogonal Frequency Division Multiplexing (OFDM) scheme is preferred technology in PLC systems because of its effective combat with frequency selective fading properties of PLC channel. As the channel estimation is one of the crucial problems in OFDM based PLC system because of a problematic area of PLC signal attenuation and interference, the improved LS est...

  8. Implementation of RS-485 Communication between PLC and PC of Distributed Control System Based on VB

    Lian Zhang, Chuan; Da Huang, Zhi; Qing Zhou, Gui; Chong, Kil To

    2015-05-01

    This paper focuses on achieving RS-485 communication between programmable logical controller (PLC) and PC based on visual basic 6.0 (VB6.0) on an experimental automatic production line. Mitsubishi FX2N PLCs and a PC are chosen as slave stations and main station, respectively. Monitoring software is developed using VB6.0 for data input/output, flow control and online parameters setting. As a result, all functions are fulfilled with robust performance. It is concluded from results that one PC can monitor several PLCs using RS-485 communication.

  9. PLC Programming

    Lee, Seong Jae; Wi, Seong Dong; Yoo, Jong Seon; Kim, Se Chan

    2001-02-01

    This book tells of PLC programming for KGL-WIN with summary of PLC, performance and function of PLC like characteristic of KGL-WIN, connection method with PLC, basic performance of K200S/K300S/K1000S, diagram of input and output H/W, writing project, staring the program, editing of program, on-line function, debugging and instructions like control, timer and counter, data transmission, comparison, rotation and moving, system, data operating data conversion and application program.

  10. Diseño e implementación de un sistema de transferencias de datos a través de la red eléctrica de baja tensión con la interfaz Labview-arduino empleando la tecnología power line communications (PLC).

    Ponce León, David; Santillán Aguirre, Sergio

    2016-01-01

    La propuesta del proyecto de titulación está basada en la implementación de un nuevo sistema de transferencia mediante tecnología Power Line Communications (PLC), Comunicación por la Red Eléctrica, que se fundamenta en la transmisión de información en diferentes puntos utilizando la red eléctrica ya existente de baja tensión en el Laboratorio de Telecomunicaciones, con la finalidad de contribuir con nuevas opciones de comunicación, de envío y recepción de información para aplicaciones tecnoló...

  11. Power Line Communications for Smart Grid Applications

    Lars Torsten Berger

    2013-01-01

    Full Text Available Power line communication, that is, using the electricity infrastructure for data transmission, is experiencing a renaissance in the context of Smart Grid. Smart Grid objectives include the integration of intermittent renewable energy sources into the electricity supply chain, securing reliable electricity delivery, and using the existing electrical infrastructure more efficiently. This paper surveys power line communications (PLCs in the context of Smart Grid. The specifications G3-PLC, PRIME, HomePlug Green PHY, and HomePlug AV2, and the standards IEEE 1901/1901.2 and ITU-T G.hn/G.hnem are discussed.

  12. Investigation of Orthogonal Frequency Division Multiplexing Based Power Line Communication Systems

    Hosseinpour, Ali

    2015-01-01

    Power Line Communication (PLC) has the potential to become the preferred technique for providing broadband to homes and offices with the advantage of eliminating the need for new wiring infrastructure and reducing the cost. Power line grids, however, present a hostile channel for data communication, since the fundamental purpose of the power line channel was only the transmission of electric power at 50/60 Hz frequencies. The development of PLC systems for providing broadband applications req...

  13. The Application of PLC (Powerline Communications) in Brazil in the regulatory viewpoint; A aplicacao do PLC no Brasil do ponto de vista regulatorio

    Vieira, Daniel; Silva Filho, Armando [Agencia Nacional de Energia Eletrica (ANEEL), Brasilia, DF (Brazil). Superintendencia de Regulacao dos Servicos de Distribuicao

    2010-07-01

    The Powerline Communications technology - PLC allows transmission of data, voice, image and access to high speed internet by the grid, so that a power plug can also be an access point to the network communication. Considering that the electric grid reaches the vast majority of households, there is great potential in using this technology as a tool to achieve the reality of digital inclusion in the country. However, its implementation must be accompanied by effective regulation, both through policies with respect to the conditions of use of radio frequencies, as in regulating the use of distribution networks of electricity as a means of transport for communication signal. In this context, the present article deals with the fundamental rules governing the application of PLC technology from the standpoint of the distributors and consumers of electricity, with attention to quality assurance of electrical energy and facility security.

  14. Design of Control System for Flexible Packaging Bags Palletizing Production Line Based on PLC

    Zheng, Huiping; Chen, Lin; Zhao, Xiaoming; Liu, Zhanyang

    Flexible packaging bags palletizing production line is to put the bags in the required area according to particular order and size, in order to finish handling, storage, loading and unloading, transportation and other logistics work of goods. Flexible packaging bags palletizing line is composed of turning bags mechanism, shaping mechanism, indexing mechanism, marshalling mechanism, pushing bags mechanism, pressing bags mechanism, laminating mechanism, elevator, tray warehouse, tray conveyor and loaded tray conveyor. Whether the whole production line can smoothly run depends on each of the above equipment and precision control among them. In this paper the technological process and the control logic of flexible packaging bags palletizing production line is introduced. Palletizing process of the production line realized automation by means of a control system based on programmable logic controller (PLC). It has the advantages of simple structure, reliable and easy maintenance etc.

  15. Strategies for Power Line Communications Smart Metering Network Deployment

    Alberto Sendin

    2014-04-01

    Full Text Available Smart Grids are becoming a reality all over the world. Nowadays, the research efforts for the introduction and deployment of these grids are mainly focused on the development of the field of Smart Metering. This emerging application requires the use of technologies to access the significant number of points of supply (PoS existing in the grid, covering the Low Voltage (LV segment with the lowest possible costs. Power Line Communications (PLC have been extensively used in electricity grids for a variety of purposes and, of late, have been the focus of renewed interest. PLC are really well suited for quick and inexpensive pervasive deployments. However, no LV grid is the same in any electricity company (utility, and the particularities of each grid evolution, architecture, circumstances and materials, makes it a challenge to deploy Smart Metering networks with PLC technologies, with the Smart Grid as an ultimate goal. This paper covers the evolution of Smart Metering networks, together with the evolution of PLC technologies until both worlds have converged to project PLC-enabled Smart Metering networks towards Smart Grid. This paper develops guidelines over a set of strategic aspects of PLC Smart Metering network deployment based on the knowledge gathered on real field; and introduces the future challenges of these networks in their evolution towards the Smart Grid.

  16. Data communication between Panasonic PLC and PC using SerialPort control in C#.NET environment

    Gao, Ting; Gan, Xiaochuan; Ma, Liqun

    2015-02-01

    With the gradual promotion of Microsoft.NET platform, C# as an object-oriented programming language based on the platform has been widely used. Therefore, more attention is concentrated on how to achieve the communication between Panasonic PLC and PC efficiently and fast in C#.NET environment. In this paper, a method of using SerialPort control which could be used for achieving communication between PLC and PC is introduced. Meanwhile, the reason of abnormal thread when displayed the receiving data in form is analyzed and the programming method to solve the problem of thread safety is designed. Achieving the communication of Panasonic PLC and PC in C#.NET environment can give full play to the advantages of the .NET framework. It is practical, easy communication, high reliability and can combine with other measurement and calibration procedures effectively and conveniently. Configuration software is expensive and can only communicate with PLC separately, but these shortcomings can be solved in C#.NET environment. A well-designed user interface realized real-time monitoring of PLC parameters and achieved management and control integration. The experiment show that this method of data transfer is accurate and the program' running is stable.

  17. Improving a Power Line Communications Standard with LDPC Codes

    Hsu Christine

    2007-01-01

    Full Text Available We investigate a power line communications (PLC scheme that could be used to enhance the HomePlug 1.0 standard, specifically its ROBO mode which provides modest throughput for the worst case PLC channel. The scheme is based on using a low-density parity-check (LDPC code, in lieu of the concatenated Reed-Solomon and convolutional codes in ROBO mode. The PLC channel is modeled with multipath fading and Middleton's class A noise. Clipping is introduced to mitigate the effect of impulsive noise. A simple and effective method is devised to estimate the variance of the clipped noise for LDPC decoding. Simulation results show that the proposed scheme outperforms the HomePlug 1.0 ROBO mode and has lower computational complexity. The proposed scheme also dispenses with the repetition of information bits in ROBO mode to gain time diversity, resulting in 4-fold increase in physical layer throughput.

  18. A Simulator of Periodically Switching Channels for Power Line Communications

    Hayasaki, Taro; Umehara, Daisuke; Denno, Satoshi; Morikura, Masahiro

    An indoor power line is one of the most attractive media for in-home networks. However, there are many technical problems for achieving in-home power line communication (PLC) with high rate and high reliability. One of such problem is the degradation in the performance of the in-home PLC caused by periodically time-varying channel responses, particularly when connecting the switching power supply equipment. We present a measurement method for power line channel responses and reveal the switching of the channel responses synchronized with power-frequency voltage when connecting switching power supply equipment in sending or receiving outlets. In this paper, we term them periodically switching channel responses. The performance of PLC adapters is seriously affected by the periodically switching channel responses. Therefore, we provide a modeling of the periodically switching channel responses by using finite impulse response (FIR) filters with a shared channel memory and construct a simulator for in-home power line channels including the periodically switching channel responses in order to evaluate the various communication systems through the power line. We present the validity of the proposed simulator through the performance evaluation of OFDM/64QAM over periodically switching channels with additive white Gaussian noise. Furthermore, we evaluate the influence of the periodically switching channel responses on the communication quality of a time-invariant modulation scheme by using the proposed simulator.

  19. Inhibitory effect of genistein on PLC/PRF5 hepatocellular carcinoma cell line

    Mehdi Nikbakht Dastjerdi

    2015-01-01

    Full Text Available Background: Natural compounds including flavonoids like genistein (GE are able to inhibit cell proliferation and induce apoptosis. GE is the main representative of these groups. GE inhibits carcinogenic tumors such as colon, stomach, lung, and pancreas tumors. The aim of the present study was to analyze the apoptotic effect of GE in the hepatocellular carcinoma (HCC PLC/PRF5 cell line. Methods: Cells were treated with various doses of GE (1, 5, 10, 25, 50, 75, and 100 μM/L at different times (24, 48, and 72 h and the MTT assay was commonly used. Furthermore, cells were treated with single dose of GE (25 μM at different times and flow cytometry was performed. Results: GE inhibited the growth of liver cancer cells significantly with a time- and dose-dependent manner. The percentage of living cells in GE treatment groups with a concentration of 25 μM at different times were 53, 48 and 47%, respectively (P < 0.001. Result of flow cytometry demonstrated that GE at a 25 μM concentration induces apoptosis significantly in a time-dependent manner. The percentage of apoptotic cells at different times were 44, 56, and 60%, respectively (P < 0.001. Conclusions: GE can significantly inhibit the growth of HCC cells and plays a significant role in apoptosis of this cell line.

  20. High-speed narrowband PLC - High-performance Access Powerline Communication structures in smart grid; High-Speed Narrowband PLC. Leistungsfaehige Access-Powerline-Kommunikationsstrukturen im Smart Grid

    Offner, Georg [devolo AG, Aachen (Germany)

    2012-07-01

    The smart grid provides a stable operation of a decentralized power system which is fed more and more by small providers by means of solar technology and wind power technology. Furthermore, commercial and private clients profit from the smart grid, as they may capture information about their current consumption in real time or can obtain these data from the Internet. The author of the contribution under consideration presents new approaches to access powerline communications that enable efficient communication between IPv6 based household meter and network station. The contribution under consideration describes the technologies used as well as practical experiences and initial results from field tests. Here insights from the integration of G3-PLC are in the foreground.

  1. Effects of 5-fluorouracil on biological characteristics and drug resistance mechanisms of liver cancer cell line PLC/RAF/5

    CHENG Kangwen

    2015-09-01

    Full Text Available ObjectiveTo study the changes in biological characteristics of a liver cancer cell line PLC/RAF/5 after repeated exposure to a chemotherapy drug, 5-fluorouraci (5-FU, and to investigate the relationship between drug-resistant liver cancer cells and liver cancer stem cells. MethodsA low concentration of 5-FU (1 μg/ml was used to treat the human liver cancer cell line PLC/RAF/5 repeatedly to establish the PLC/RAF/5/5-FU cell line. Morphological differences between the two types of cells were observed. The inhibitory effects of different concentrations of 5-FU (0, 0.25, 0.5, 1, 1.5, and 2 μg/ml on the proliferation of the two types of cells were determined using the CCK-8 assay. Apoptosis of the two types of cells after exposure to different concentrations of 5-FU (0.5, 1, and 2 μg/ml for 48 h was analyzed using flow cytometry. The proportions of side population cells in both types of cells were measured using flow cytometry. The colony-forming ability was compared between the two types of cells by the plate colony-forming assay. The expression of Bax, Bcl-2, ABCG2, and FoxM1 proteins in both types of cells was examined by Western blot. Between-group comparison was performed by t test. ResultsThe PLC/RAF/5/5-FU cell line was successfully established using the chemotherapy drug 5-FU. Compared with the PLC/RAF/5 cells, the PLC/RAF/5/5-FU cells had a larger volume, fewer protrusions, a changed shape of a long shuttle, and enhanced refractivity. Moreover, compared with the parent cells, the PLC/RAF/5/5-FU cells had a significantly lower sensitivity to the inhibitory effect of 5-FU on proliferation, a significantly lower proportion of cells at the G0/G1 phase of the cell cycle, significantly higher proportions of cells at the S and G2/M phases, significantly higher resistance to apoptosis, a significantly higher proportion of side population cells, and significantly enhanced proliferation (P<0.05. According to the results of Western blot assay, the

  2. Smart Grid Applications for a Practical Implementation of IP over Narrowband Power Line Communications

    Noelia Uribe-Pérez

    2017-11-01

    Full Text Available Currently, Advanced Metering Infrastructure (AMI systems have equipped the low voltage section with a communication system that is being used mainly for metering purposes, but it can be further employed for additional applications related to the Smart Grid (SG concept. This paper explores the potential applications beyond metering of the available channel in a Power Line Communication-based AMI system. To that end, IP has been implemented over Narrow Band-Power Line Communication (NB-PLC in a real microgrid, which includes an AMI system. A thorough review of potential applications for the SG that might be implemented for this representative case is included in order to provide a realistic analysis of the potentiality of NB-PLC beyond smart metering. The results demonstrate that existing AMI systems based on NB-PLC have the capacity to implement additional applications such as remote commands or status signals, which entails an added value for deployed AMI systems.

  3. Fast Burst Synchronization for Power Line Communication Systems

    Lampe Lutz

    2007-01-01

    Full Text Available Fast burst synchronization is an important requirement in asynchronous communication networks, where devices transmit short data packets in an unscheduled fashion. Such a synchronization is typically achieved by means of a preamble sent in front of the data packet. In this paper, we study fast burst synchronization for power line communication (PLC systems operating below 500 kHz and transmitting data rates of up to about 500 kbps as it is typical in various PLC network applications. In particular, we are concerned with the receiver processing of the preamble signal and the actual design of preambles suitable for fast burst synchronization in such PLC systems. Our approach is comprehensive in that it takes into account the most distinctive characteristics of the power line channel, which are multipath propagation, highly varying path loss, and disturbance by impulse noise, as well as important practical constraints, especially the need for spectral shaping of the preamble signal and fast adjustment of the automatic gain control (AGC. In fact, we regard the explicit incorporation of these various requirements into the preamble design as the main contribution of this work. We devise an optimization criterion and a stochastic algorithm to search for suitable preamble sequences. A comprehensive performance comparison of a designed and two conventional preambles shows that the designed sequence is superior in terms of (a fast burst synchronization in various transmission environments, (b fast AGC adjustment, and (c compliance of its spectrum with the spectral mask applied to the data transmit signal.

  4. Impulsive Noise Characterization in Narrowband Power Line Communication

    Li Bai

    2018-04-01

    Full Text Available Currently, narrowband Power line communication (PLC is considered an attractive communication system in smart grid environments for applications such as advanced metering infrastructure (AMI. In this paper, we will present a comprehensive comparison and analysis in time and frequency domain of noise measured in China and Italy. In addition, impulsive noise in these two countries are mainly analyzed and modeled using two probability based models, Middleton Class A (MCA model and α stable distribution model. The results prove that noise measured in China is rich in impulsive noise, and can be modeled well by α stable distribution model, while noise measured in Italy has less impulsive noise, and can be better modeled by the MCA model.

  5. Προσδιορισμός της απόδοσης αγωγών υψηλής τάσης για τη χρήση PowerLine Communication (PLC)

    Μουστάκα, Μαρία; Σταμούλη, Αλεξία

    2011-01-01

    Ο στόχος της διπλωματικής αυτής είναι η περιγραφή της αναδυόμενης τεχνολογίας PLC (PowerLine Communication). Η τεχνολογία αυτή με τη χρήση του πανταχού παρόντος ηλεκτρικού δικτύου προσφέρει ακόμα και σε απομακρυσμένους χρήστες πληθώρα ευρυζωνικών υπηρεσιών και πρόσβαση στο διαδίκτυο, αποτελώντας μια ανταγωνιστική επιλογή τρόπου επικοινωνίας. Για την κατανόηση της PLC τεχνολογίας αρχικά κρίνουμε απαραίτητη την λεπτομερή περιγραφή της δομής του ηλεκτρικού δικτύου, του εξοπλισμού που απαιτείται ...

  6. Estudio para la automatización de la lectura, corte y reconexión de la energía eléctrica mediante tecnología PLC (Power Line Communication). Caso de análisis : Empresa Eléctrica Regional CentroSur C.A.

    Quizhpi Montero, Diego Armando; Ruiz Orellana, José Luis

    2007-01-01

    La finalidad de esta tesis es entregar una mayor información sobre la tecnología PLC, como sus bases teóricas y de cómo aprovecha el tendido de red eléctrica para la lectura, corte y reconexión de los contadores de energía eléctrica mediante la utilización de equipos adecuados. La tecnología PLC también permite ofrecer una diversidad de servicios de telecomunicaciones, tales como: voz, video y datos, el cual se lo conoce como triple-play. Al momento de transmitir datos por el tendido el...

  7. Transmission Characteristics of an OFDM signal for Power Line Communication System with High Bit Rate

    Mori, Akira; Watanabe, Yosuke; Tokuda, Masamitsu; Kawamoto, Koji

    In this paper, we measured what influence the sinusoidal transmission characteristics of the electric power line with various forms gave to the transmission characteristic of OFDM (Orthogonal Frequency Division Multiplexing) signal through PLC (power line communication system) modem. We classified the electric power line transmission line with various forms in a real environment into two basic elements, which are an outlet type branch and a switch type branch. Next, PHY rate (Physical rate) is measured for each basic element connected with the PLC modem. At this time, the transmission characteristics of the electric power line are simulated from measured data. OFDM sending and receiving systems are composed on the computer, and the PHY rate is simulated. By comparing with measured and calculated values, it is revealed that PHY rate of PLC modem is most affected in the case of the power line transmission characteristics having broad band and high level attenuation and group delay variation, and is not affected in the case of that having narrow band attenuation and group delay variation.

  8. A High-Speed Power-Line Communication System with Band-Limited OQAM Based Multi-Carrier Transmission

    Kawabata, Naohiro; Koga, Hisao; Muta, Osamu; Akaiwa, Yoshihiko

    As a method to realize a high-speed communication in the home network, the power-line communication (PLC) technique is known. A problem of PLC is that leakage radiation interferes with existing systems. When OFDM is used in a PLC system, the leakage radiation is not sufficiently reduced, even if the subcarriers corresponding to the frequency-band of the existing system are never used, because the signal is not strictly band-limited. To solve this problem, each subcarrier must be band-limited. In this paper, we apply the OQAM based multi-carrier transmission (OQAM-MCT) to a high-speed PLC system, where each subcarrier is individually band-limited. We also propose a pilot-symbol sequence suitable for frequency offset estimation, symbol-timing detection and channel estimation in the OQAM-MCT system. In this method, the pilot signal-sequence consists of a repeated series of the same data symbol. With this method, the pilot sequence approximately becomes equivalent to OFDM sequence and therefore existing pilot-assisted methods for OFDM are also applicable to OQAM-MCT system. Computer simulation results show that the OQAM-MCT system achieves both good transmission rate performance and low out-of-band radiation in PLC channels. It is also shown that the proposed pilot-sequence improves frequency offset estimation, symbol-timing detection and channel estimation performance as compared with the case of using pseudo-noise sequence.

  9. Simulation of a Narrowband Power Line Communications System over Medium Voltage

    Nikolaos Chiotellis

    2016-03-01

    Full Text Available Narrowband Power Line Communications (NB-PLCs are investigated as an alternative option for transferring low rate smart grid (SG data via Medium Voltage (MV power lines. In this framework, two variants of orthogonal frequency division multiplexing are examined, namely Filtered-OFDM (F-OFDM and Wavelet-OFDM (W-OFDM, in an attempt to determine which of them is capable of transmitting low rate SG data to greater distances over non-branched MV power lines. The reach of NB-PLC signals via MV power lines is estimated, taking into account the transfer function of the relevant PLC channels and noise mechanisms as well as the specific features of the two modulation options under consideration. Simulations show that NB-PLC transmission constitutes a technically feasible and economically affordable option for exchanging low rate data with remote SG nodes dispersed over the MV grid. Moreover, simulations show that F-OFDM allows low rate data transmission to considerably greater distances compared to W-OFDM.

  10. Development of radioactive source scanner based on PLC

    Yang Guogui; Gao Xiang; Guo Hongli

    2013-01-01

    The radioactive radial uniformity of 68 Ge line radioactive sources is a critical quality parameter. The radioactive source scanner with linear scanning function is developed by making use of high-speed pulse counters, high-speed pulse output ports, and the powerful instruction system of Siemens S7-200 series programmable logic controller (PLC). A computer used as a host computer of the instrument communicate with. the PLC by point to point interface (PPI) protocol, The instrument with functions of data collection, transmission, displaying, saving, motion control and instrument parameter settings, can be used to measure the radioactive radial uniformity and total activity of line radioactive source. The advantages of Using the PLC to develop nuclear instrumentation are development speed, strong anti-interference ability, and low-cost. This paper mainly describes the control system implementation and feature of the instrument. (authors)

  11. NB-PLC channel modelling with cyclostationary noise addition & OFDM implementation for smart grid

    Thomas, Togis; Gupta, K. K.

    2016-03-01

    Power line communication (PLC) technology can be a viable solution for the future ubiquitous networks because it provides a cheaper alternative to other wired technology currently being used for communication. In smart grid Power Line Communication (PLC) is used to support communication with low rate on low voltage (LV) distribution network. In this paper, we propose the channel modelling of narrowband (NB) PLC in the frequency range 5 KHz to 500 KHz by using ABCD parameter with cyclostationary noise addition. Behaviour of the channel was studied by the addition of 11KV/230V transformer, by varying load location and load. Bit error rate (BER) Vs signal to noise ratio SNR) was plotted for the proposed model by employing OFDM. Our simulation results based on the proposed channel model show an acceptable performance in terms of bit error rate versus signal to noise ratio, which enables communication required for smart grid applications.

  12. β Absorption dust concentration monitor system based on the PLC

    Lian Dexing; Zhou Xiuliang; Liu Liyan; Li Zonglun; Cao Guanghui; Mao Wanchong

    2011-01-01

    To provide an on-line automatic system for dust concentration monitor is the purpose of this design.The system based on β-ray-absorption-method,employing PLC (Programmable Logic Controller) control technology, is presented. The user input parameter setup,the data acquisition and processing, and the communication with computer can be effectively regulated using the advanced PLC control technology. It has the features of high reliability, easy operation and easy maintenance, and the ability to monitor remotely. Measurement range: 0.1-1500 mg/m 3 , Accuracy: ±9%. The structure,working principle, electric circuit and software development of the system are introduced in detail. (authors)

  13. Efficient Implementation of a Symbol Timing Estimator for Broadband PLC.

    Nombela, Francisco; García, Enrique; Mateos, Raúl; Hernández, Álvaro

    2015-08-21

    Broadband Power Line Communications (PLC) have taken advantage of the research advances in multi-carrier modulations to mitigate frequency selective fading, and their adoption opens up a myriad of applications in the field of sensory and automation systems, multimedia connectivity or smart spaces. Nonetheless, the use of these multi-carrier modulations, such as Wavelet-OFDM, requires a highly accurate symbol timing estimation for reliably recovering of transmitted data. Furthermore, the PLC channel presents some particularities that prevent the direct use of previous synchronization algorithms proposed in wireless communication systems. Therefore more research effort should be involved in the design and implementation of novel and robust synchronization algorithms for PLC, thus enabling real-time synchronization. This paper proposes a symbol timing estimator for broadband PLC based on cross-correlation with multilevel complementary sequences or Zadoff-Chu sequences and its efficient implementation in a FPGA; the obtained results show a 90% of success rate in symbol timing estimation for a certain PLC channel model and a reduced resource consumption for its implementation in a Xilinx Kyntex FPGA.

  14. Efficient Implementation of a Symbol Timing Estimator for Broadband PLC

    Francisco Nombela

    2015-08-01

    Full Text Available Broadband Power Line Communications (PLC have taken advantage of the research advances in multi-carrier modulations to mitigate frequency selective fading, and their adoption opens up a myriad of applications in the field of sensory and automation systems, multimedia connectivity or smart spaces. Nonetheless, the use of these multi-carrier modulations, such as Wavelet-OFDM, requires a highly accurate symbol timing estimation for reliably recovering of transmitted data. Furthermore, the PLC channel presents some particularities that prevent the direct use of previous synchronization algorithms proposed in wireless communication systems. Therefore more research effort should be involved in the design and implementation of novel and robust synchronization algorithms for PLC, thus enabling real-time synchronization. This paper proposes a symbol timing estimator for broadband PLC based on cross-correlation with multilevel complementary sequences or Zadoff-Chu sequences and its efficient implementation in a FPGA; the obtained results show a 90% of success rate in symbol timing estimation for a certain PLC channel model and a reduced resource consumption for its implementation in a Xilinx Kyntex FPGA.

  15. Line supervision of alarm communications

    Chritton, M.R.

    1991-01-01

    The objective of this paper is to explain the role and application of alarm communication link supervision in security systems such as for nuclear facilities. The vulnerabilities of the various types of alarm communication links will be presented. Throughout the paper, an effort has been made to describe only those technologies commercially available and to avoid speculative theoretical solutions

  16. Conducted Interference Immunity Characteristics to High-speed Power Line Communication System

    Tokuda, Masamitsu; Hosoya, Satoshi; Yamagata, Toru; Matsuo, Takashi

    In this paper, we measured the immunity characteristics to the conducted interference wave, from the aspect of PHY rate (physical layer data rate) of PLC (Power Line Communication) system, and compared with simulation results by MATLAB/ Simulink. When the interference signal is impressed to the OFDM (Orthogonal Frequency Division Multiplexing) signal, the PHY rate decrease rapidly below C/I (Carrier / Interference) = 25dB and become nearly zero around C/I = -35dB, and so it turns out that the PLC System with OFDM signal has a good narrowband interference immunity characteristic. In addition, it is revealed that the PHY rate of PLC modem can be calculated by MATLAB/Simulink even when the narrowband interference signal is impressed through the power line. Furthermore, we examined the improving effect of the notch band for the immunity characteristics to the conducted interference wave. As a result, it is revealed that the PHY rate normalized by the maximum value increases by 15∼25% by inserting the notch when impressing the interference signal in the notch band and C/I is improved by 10∼15dB by inserting the notch.

  17. Homeplug AV and IEEE 1901 a handbook for PLC designers and users

    Latchman, Haniph A; Yonge, Larry; Gavette, Sherman

    2013-01-01

      The only authorized book explaining the HomePlug networking standards HomePlug is a growing technology for creating high-speed Power Line Communication (PLC) networks by transmitting data over in-home or in-office power lines. Users only need to plug adapters into wall outlets to create an instant network of computers, printers, routers, home entertainment

  18. DISAIN SISTEM KENDALI MESIN AIR LEAK TEST MENGGUNAKAN SISTEM KENDALI PLC OMRON CJ2M DI HVAC (HEATING, VENTILATING, AND AIR CONDITIONING LINE 6

    Syahril Ardi

    2015-03-01

    Full Text Available Pada proses produksi pembuatan komponen HVAC (Heating, Ventilating, and Air Conditioning dari perusahaan manufaktur di Indonesia, memerlukan proses pengecekan kebocoran pada bagian HVAC. Proses pengecekan ini dilakukan untuk memastikan tidak ada komponen HVAC yang bocor sebelum dikirim ke pihak pelanggan. Penelitian ini dilakukan untuk membuat system dan alat air leak test. Mesin air leak test ini menggunakan prinsip kerja differential pressure air leak test, yaitu metode yang membandingkan antara tekanan udara yang diberikan ke produk dan master produk. Pada penelitian ini, kami membuat disain mesin air leak test menggunakan sistem kendali berupa air leak tester, PLC, dan HMI. Berdasarkan kondisi dengan kapasitas produksi yang meningkat karena bertambahnya permintaan dari customer, dapat ditanggulangi dengan adanya share loading produksi dari HVAC line 4 ke line baru, yaitu HVAC line 6. Hasil yang didapat dari pengujian deteksi kebocoran produk,didapat nilai parameter kebocoran produk sebesar 2.23 ml/min.

  19. Solucions PLC obertes

    López Llauradó, Oriol

    2006-01-01

    Treball que, després de revisar el concepte de PLC i d'exposar la necessitat de solucions obertes, defineix el concepte de PLC obert, basat en programari lliure i presenta alguns projectes interessants de PLC obert. Trabajo que, después de revisar el concepto de PLC y de exponer la necesidad de soluciones abiertas, define el concepto de PLC abierto, basado en el software libre y presenta algunos proyectos interesantes de PLC abierto. Study that, after looking at the concept of PLC and s...

  20. Joint Use of Adaptive Equalization and Cyclic Noise Cancellation for Band-Limited OQAM Based Multi-Carrier Transmission in Power-Line Communication Systems

    Kunishima, Hiromitsu; Koga, Hisao; Muta, Osamu; Akaiwa, Yoshihiko

    Power-line communication (PLC) technique is one method to realize high-speed communications in a home network. In PLC channels, the transmission signal quality is degraded by colored non-Gaussian noise as well as frequency-selectivity of the channels. In this paper, we describe our investigation of the performance of a OQAM-MCT system in which a noise canceller is used jointly with a time-domain per-subcarrier adaptive equalizer. Furthermore, we propose a noise cancellation method designed for the OQAM-MCT system. The performance of the OQAM-MCT system is evaluated in PLC channels with measured impulse responses in the presence of measured noise. Computer simulation results show that the bit rate of the OQAM-MCT system is improved using both an adaptive equalizer and noise canceller, and that the OQAM-MCT system achieves better performance than an OFDM system with an insufficient length of the guard interval.

  1. Performance Evaluation of CE-OFDM in PLC Channel

    El ghzaoui Mohammed, Belkadid Jamal, Benbassou Ali

    2011-01-01

    One major drawback associated with an OFDM system is that the transmitter’soutput signal may have a high peak-to-average ratio (PAPR). High levels of PARmay be a limiting factor for power line communication (PLC) where regulatorybodies have fixed the maximum amount of transmit power. To overcome thisproblem, many approaches have been presented in the literature. One potentialsolution for reducing the peak-to-average power ratio (PAPR) in an OFDMsystem is to utilize a constant envelope OFDM (C...

  2. Noise Sources, Effects and Countermeasures in Narrowband Power-Line Communications Networks: A Practical Approach

    Gregorio López

    2017-08-01

    Full Text Available The integration of Distributed Generation, Electric Vehicles, and storage without compromising the quality of the power delivery requires the deployment of a communications overlay that allows monitoring and controlling low voltage networks in almost real time. Power Line Communications are gaining momentum for this purpose since they present a great trade-off between economic and technical features. However, the power lines also represent a harsh communications medium which presents different problems such as noise, which is indeed affected by Distributed Generation, Electric Vehicles, and storage. This paper provides a comprehensive overview of the types of noise that affects Narrowband Power Line Communications, including normative noises, noises coming from common electronic devices measured in actual operational power distribution networks, and noises coming from photovoltaic inverters and electric vehicle charging spots measured in a controlled environment. The paper also reviews several techniques to mitigate the effects of noise, paying special attention to passive filtering, as for being one of the most widely used solution to avoid this kind of problems in the field. In addition, the paper presents a set of tests carried out to evaluate the impact of some representative noises on Narrowband Power Line Communications network performance, as well as the effectiveness of different passive filter configurations to mitigate such an impact. In addition, the considered sources of noise can also bring value to further improve PLC communications in the new scenarios of the Smart Grid as an input to theoretical models or simulations.

  3. Purification of HBsAg produced by the human hepatoma cell line PLC/PRE/5 by affinity chromatography using monoclonal antibodies and application for ELISA diagnostic.

    Merten, O W; Reiter, S; Scheirer, W; Katinger, H

    1983-01-01

    The human cell line PLC/PRF/5 (5) was used for the production of hepatitis B surface antigen subtype ad (HBsAg ad) and purified by affinity chromatography (AC) with monoclonal antibodies (mAb). mAb to HBsAg from mouse ascites have been purified by Protein A - AC prior coupling to AH-Sepharose 4B (Pharmacia). The combined procedure of ammonium-sulphate-precipitation of HBsAg from culture supernatants and immunosorbent-AC leads to approx. 700-fold purification. ELISA results using the mAb and the HBsAg for diagnostics of human serum, positive for anti-HBsAg-antibodies correlate with the RIA (AUSAB, Abbott).

  4. OFDM techniques for narrow-band power line communications; OFDM-Verfahren fuer die schmalbandige Datenuebertragung im elektrischen Energieversorgungsnetz

    Hoch, Martin

    2012-07-01

    In Power Line Communications (PLC) the power distribution grid is modelled by a frequency-selective time-variant channel. Therefore, OFDM techniques are suited very well for this application since they equalize the frequency-selective behaviour in a simple fashion. For narrow-band PLC, where only little amounts of data are to be transmitted, it is advantageous to employ a non-coherent system that does not need a training sequence for channel estimation. Such type of system can be brought up with CyclicPrefix OFDM in combination with Differential Phase-Shift Keying (DPSK). In an alternative, Unique-Word OFDM, the guard interval is not filled by a cyclic prefix, but a ''unique word'', which can be deployed for channel estimation. However, there is a loss in signal-to-noise power ratio due to the special type of signal generation. This loss can be more than regained in principle, but only by applying expensive detection. Another interesting technique is Wavelet-OFDM as its transmit spectrum can be formed outstandingly because of extended transmit pulses. This implies a large overhead when short packets of data are transmitted - additionally to a training sequence, for non-coherent detection is not possible. Cyclic-Prefix OFDM and DPSK are the basis of the Physical Layers of the PLC systems ''PLC G3'' and ''PRIME''. Comparing their specifications and analyzing simulation results ''PLC G3'' turns out to be the more reliable system. In order to equalize the time-variant behaviour of the power line channel, linear equalization and Multiple Symbol Differential Detection is studied as well as algorithms to estimate the time-variant envelope. (orig.)

  5. Optical buffer based on monolithic InP phased-array 1×16 switch with silica-PLC pitch converter and ultra-compact coiled fiber delay lines

    Tanemura, T.; Soganci, I. M.; Oyama, T.; Ohyama, T.; Mino, S.; Williams, K. A.; Calabretta, N.; Dorren, H. J S; Nakano, Y.

    2010-01-01

    We demonstrate large-capacity high-resolution optical buffer, comprising 1×16 InP switch and ultra-compact delay lines based on thin-cladding highly nonlinear fibers. Silica-PLC-based pitch converter is employed to realize uniform coupling from all 16 switch ports simultaneously.

  6. The electromagnetic compatibility of the PLC technology; La compatibilite electromagnetique de la technologie CPL. Des donnees sur les lignes electriques

    Bermudez, J.-L.; Marthe, E.; Rachidi, F.; Rubinstein, M.; Vukicevic, A.

    2006-07-01

    PLC (Power Line Communications) in Europe or BPL (Broadband over Power Lines) in the US are techniques that allows the utilization of low and middle voltage power lines for the transmission of high frequencies by coupling electrical signals to them. In this way, unshielded power lines may be used for the transmission of numerical information similar to the well known xDSL-techniques using telephone lines. Typically, the frequency range used by PLC is between 9 kHz and 30 MHz. The authors describe the general principles and investigate possible electromagnetic interference with existing radio frequency equipment like xDSL, CATV (Cable Television) and Wireless (GSM, Bluetooth, WiFi). Finally, they present theoretical and experimental results of techniques allowing the reduction of such interference by reducing the emission of electromagnetic signals from PLC systems. The preferred method is based on an active control by injecting an auxiliary signal into the third conductor (ground)

  7. Cybersecurity Vulnerability Analysis of the PLC PRIME Standard

    Miguel Seijo Simó

    2017-01-01

    Full Text Available Security in critical infrastructures such as the power grid is of vital importance. The Smart Grid puts power grid classical security approach on the ropes, since it introduces cyberphysical systems where devices, communications, and information systems must be protected. PoweRline Intelligent Metering Evolution (PRIME is a Narrowband Power-Line Communications (NB-PLC protocol widely used in the last mile of Advanced Metering Infrastructure (AMI deployments, playing a key role in the Smart Grid. Therefore, this work aims to unveil the cybersecurity vulnerabilities present in PRIME standard, proposing solutions and validating and discussing the results obtained.

  8. 78 FR 10172 - Lisa Anne Cornell and G. Ware Cornell, Jr. v. Princess Cruise Lines, Ltd. (Corp), Carnival PLC...

    2013-02-13

    ... laws of the United Kingdom which does business under the names of Cunard Line, P&O Cruises, and P&O Cruises Australia as a common carrier for hire of passengers from ports in the United States;'' and...

  9. Enterprise network with software Asterisk PBX based on the PLC technology

    Michal Maar

    2017-01-01

    Full Text Available This article presents the software Asterisk PBX solution design in enterprise PLC network (Power Line Communication. The description of the installation and configuration of software Asterisk PBX is involved in the design. The secure interconnection of two enterprise PLC network is implemented via the telecommunication tunnel with security grant using the Cisco routers. The connection between two Asterisk PBXs is designed in context of the establishment of the tunnel. The subject of the article is also cross/connection of exchanges Asterisk PBX and hardware PBX - IP Panasonic PBX K-NS500.

  10. Circuit for Communication Over Power Lines

    Krasowski, Michael J.; Prokop, Normal F.; Greer, Lawrence C., III; Nappier, Jennifer

    2011-01-01

    Many distributed systems share common sensors and instruments along with a common power line supplying current to the system. A communication technique and circuit has been developed that allows for the simple inclusion of an instrument, sensor, or actuator node within any system containing a common power bus. Wherever power is available, a node can be added, which can then draw power for itself, its associated sensors, and actuators from the power bus all while communicating with other nodes on the power bus. The technique modulates a DC power bus through capacitive coupling using on-off keying (OOK), and receives and demodulates the signal from the DC power bus through the same capacitive coupling. The circuit acts as serial modem for the physical power line communication. The circuit and technique can be made of commercially available components or included in an application specific integrated circuit (ASIC) design, which allows for the circuit to be included in current designs with additional circuitry or embedded into new designs. This device and technique moves computational, sensing, and actuation abilities closer to the source, and allows for the networking of multiple similar nodes to each other and to a central processor. This technique also allows for reconfigurable systems by adding or removing nodes at any time. It can do so using nothing more than the in situ power wiring of the system.

  11. A Measurement and Power Line Communication System Design for Renewable Smart Grids

    Kabalci, E.; Kabalci, Y.

    2013-10-01

    The data communication over the electric power lines can be managed easily and economically since the grid connections are already spread around all over the world. This paper investigates the applicability of Power Line Communication (PLC) in an energy generation system that is based on photovoltaic (PV) panels with the modeling study in Matlab/Simulink. The Simulink model covers the designed PV panels, boost converter with Perturb and Observe (P&O) control algorithm, full bridge inverter, and the binary phase shift keying (BPSK) modem that is utilized to transfer the measured data over the power lines. This study proposes a novel method to use the electrical power lines not only for carrying the line voltage but also to transmit the measurements of the renewable energy generation plants. Hence, it is aimed at minimizing the additional monitoring costs such as SCADA, Ethernet-based or GSM based systems by using the proposed technique. Although this study is performed with solar power plants, the proposed model can be applied to other renewable generation systems. Consequently, the usage of the proposed technique instead of SCADA or Ethernet-based systems eliminates additional monitoring costs.

  12. Short distance line of sight laser communication

    Mudassar, A.A.; Hussain, H.; Jamil-ur-Rehman

    1998-01-01

    Communication methods based on lasers as carrier are well known. In our work we have made a two way laser based communication system for short range (<2 Km) line of sight communication. A small piece of plane mirror (100% reflector) was mounted on the centre of a speaker cone. The speaker was positioned close to the opening of laser such that He-Ne laser beam (10 mW) after reflection from the mirror is directed towards the receiver. There is a pre-amplifier and an amplifier between a microphone and the speaker. When the diagram of the speaker vibrates, it positionally modulates the laser beam. On the receiving end, there is a photo diode, a pre-amplifier, an amplifier and a head phone. So the man on the receiving end can decode the sound signal. On each stage there is a transmitter and a receiver assembled close to each other. So the two way communication is possible in the range 20 to 20 Khz. (author)

  13. Estimating the Theoretical Value for LAN Network Throughput Based Power Line Communications Technology Under the Homeplug 1.0 Standard

    Martha Fabiola Contreras Higuera

    2013-06-01

    Full Text Available Power Line Communications (PLC refers to a group of technologies that allow to establish communication processes under the use of the grid as a physical means of transmission. The use of the grid as a physical means of transmission of information is not a new idea. Until a few years ago, the use of PLC had been limited to the implementation of solutions of control, automation and monitoring of sensors; which did not require a high bandwidth for its operation.During the late 1990s due to the new technological developments and the need to implement new alternatives for transfer of information, it was possible to reach speeds on the order of the Mbps, establishing the possibility of making use of the electricity network as a network of access. The current state of technology PLC allows to reach speeds of up to 200Mbps, which has enabled the transformation of the grid in a true network of band wide, capable of supporting data, voice and video provided by a telecommunications operator. The use of PLC-based network adapters allow easily design LANs and broadband communications through the electrical network, making any outlet in a point of connection for the user, without the need for wiring additional to existing ones.  The electrical network is a structure which so far has been exclusively used for the transport of electrical energy. However, it is possible to make use of this network in processes of communication and transmission of information such as: voice, data and video; Bearing in mind that grid had not been designed for this purpose. The performance is without doubt one of the aspects of greatest interest in the global analysis in networks LAN, due to the effect it produces on the end user. Basically, the most common parameters for evaluating the performance of a network are: Throughput, use of the canal and various measures of retardation. In this article is presented a simple analysis of the HomePlug 1.0 standard applied to the

  14. Performance Evaluation of CE-OFDM in PLC Channel

    El Ghzaoui Mohammed; Belkadid Jamal; Benbassou Ali

    2011-01-01

    One major drawback associated with an OFDM system is that the transmitter’s output signal may have a high peak-to-average ratio (PAPR). High levels of PAR may be a limiting factor for power line communication (PLC) where regulatory bodies have fixed the maximum amount of transmit power. To overcome this problem, many approaches have been presented in the literature. One potential solution for reducing the peak-to-average power ratio (PAPR) in an OFDM system is to utilize a constant envelope O...

  15. Transacsys PLC - Final Results

    2002-01-01

    Final results from Transacsys PLC. A subsidary of this company was set up to develop the CERN EDH system into a commercial product but incurred too much financial loss so the project was cancelled (1/2 page).

  16. The Communication System using One Communication Line during a Physical Contact

    平田, 隆幸; 大場, 公隆

    2009-01-01

    The communication system during a physical contact for swarm robots was modified. An algorithm for the contact communication system using one communication line was proposed. Although we don't aim to make the perfect communication system free from a miss in data transmission, the success rate of communication is an important factor for the design of communication system. We tested the performance of of our modified communication system. The success rate of communication was considerably impro...

  17. Apparatus and Method for Communication over Power Lines

    Krasowski, Michael J. (Inventor); Prokop, Norman F. (Inventor); Greer, III, Lawrence C. (Inventor); Nappier, Jennifer M. (Inventor)

    2017-01-01

    An apparatus and method are provided for communicating over power lines. The apparatus includes a coupling modem that is situated between a power line and a device. The coupling modem is configured to demodulate a signal received from the power line into a sine signal and a cosine signal. The coupling modem is also configured to modulate a communicated bit stream received from the device into a transmitted signal in order to impose the transmitted signal onto the power line.

  18. Resource Allocation with Adaptive Spread Spectrum OFDM Using 2D Spreading for Power Line Communications

    Baudais Jean-Yves

    2007-01-01

    Full Text Available Bit-loading techniques based on orthogonal frequency division mutiplexing (OFDM are frequently used over wireline channels. In the power line context, channel state information can reasonably be obtained at both transmitter and receiver sides, and adaptive loading can advantageously be carried out. In this paper, we propose to apply loading principles to an spread spectrum OFDM (SS-OFDM waveform which is a multicarrier system using 2D spreading in the time and frequency domains. The presented algorithm handles the subcarriers, spreading codes, bits and energies assignment in order to maximize the data rate and the range of the communication system. The optimization is realized at a target symbol error rate and under spectral mask constraint as usually imposed. The analytical study shows that the merging principle realized by the spreading code improves the rate and the range of the discrete multitone (DMT system in single and multiuser contexts. Simulations have been run over measured power line communication (PLC channel responses and highlight that the proposed system is all the more interesting than the received signal-to-noise ratio (SNR is low.

  19. Resource Allocation with Adaptive Spread Spectrum OFDM Using 2D Spreading for Power Line Communications

    Baudais, Jean-Yves; Crussière, Matthieu

    2007-12-01

    Bit-loading techniques based on orthogonal frequency division mutiplexing (OFDM) are frequently used over wireline channels. In the power line context, channel state information can reasonably be obtained at both transmitter and receiver sides, and adaptive loading can advantageously be carried out. In this paper, we propose to apply loading principles to an spread spectrum OFDM (SS-OFDM) waveform which is a multicarrier system using 2D spreading in the time and frequency domains. The presented algorithm handles the subcarriers, spreading codes, bits and energies assignment in order to maximize the data rate and the range of the communication system. The optimization is realized at a target symbol error rate and under spectral mask constraint as usually imposed. The analytical study shows that the merging principle realized by the spreading code improves the rate and the range of the discrete multitone (DMT) system in single and multiuser contexts. Simulations have been run over measured power line communication (PLC) channel responses and highlight that the proposed system is all the more interesting than the received signal-to-noise ratio (SNR) is low.

  20. Development of a Handheld Line Information Reader and Generator for Efficient Management of Optical Communication Lines.

    Lee, Jaeyul; Kwon, Hyungwoo; Song, Jaewon; Jeon, Mansik; Kim, Jeehyun

    2017-08-24

    A handheld line information reader and a line information generator were developed for the efficient management of optical communication lines. The line information reader consists of a photo diode, trans-impedance amplifier, voltage amplifier, microcontroller unit, display panel, and communication modules. The line information generator consists of a laser diode, laser driving circuits, microcontroller unit, and communication modules. The line information reader can detect the optical radiation field of the test line by bending the optical fiber. To enhance the sensitivity of the line information reader, an additional lens was used with a focal length of 4.51 mm. Moreover, the simulation results obtained through BeamPROP ® software from Synopsys, Inc. demonstrated a stronger optical radiation field of the fiber due to a longer transmission wavelength and larger bending angle of the fiber. Therefore, the developed devices can be considered as useful tools for the efficient management of optical communication lines.

  1. Design and development of PLC based offline impedance matching system for ICRH experiment

    Joshi, Ramesh; Jadav, H.M.; Mali, Aniruddh; Kulkarni, S.V.

    2015-01-01

    Ion Cyclotron Resonance Heating (ICRH) transmission line has two impedance matching networks, one for offline matching which has been employed before experimental shot. Another is online impedance matching which has been employed during experimental shot. Offline matching network consists of two static stubs, coarse tuner and coarse phase shifter identical in both transmission lines. There are motorized arrangement installed in each stubs and phase shifters. Both stubs are being used to vary transmission line length. Phase shifter is used to match the frequency of generated RF power. Programmable Logic Controller (PLC) based automation and control technique has been designed and developed for the system. Offline matching should be operated below 1 kHz frequency in order to move stepper motors. Program generates required square pulses which employed to motor controller to move either in upward or downward direction. In existing system this operation has been carried out using VME. To reduce the load on VME, PLC based system has been designed and integrated with main DAC system. WinCC software has been used (as SCADA/HMI) to develop front end GUI which communicates with OPC server. Further, OPC communicates with PLC for control of motorized arrangement. This paper describes technical details,design and development of PLC based offline matching system using WinCC as user interface. The communication between WinCC application and hardware devices was realized by OPC technique. The developed system has friendly graphical user interface, high-level automation and comprehensive function such as experimental process control. The system was proved to be reliable and accurate in practical application. (author)

  2. Power Line Communication Experiment using Wavelet OFDM in U.S..

    Koga, Hisao; Kodama, Nobutaka

    Recently, the demand of high speed network in home is increasing, and PLC is expected as one of the solutions. We can see related researches on the high speed PLC system using a frequency band 2 MHz to 30 MHz. In this paper, we propose a wavelet based OFDM as a suitable method for realizing the high speed PLC system. The proposed wavelet OFDM method is composed of the M-band transmultiplexer which consists of the perfect reconstruction cosine-modulated filter bank. And the attenuation of the first side-lobe is above 35dB, which is a characteristic of the proposed method. As a result, we show that the proposed method has the inter-carrier interference characteristic which is superior to FFT-OFDM, and it also provides the flexible notch filter function which can reduce the influence on other communication systems existing in the communication band which the PLC uses. Finally, we describe that the simulation results about the BER characteristic of the proposed method in AWGN were almost the same as the theory, and that transmission rates which were measured by using prototype modems in a field test house in U.S. were above 35Mbps.

  3. Study of data transmission over drive motor power cables of a remotely operated robot using power line communication technology

    Balaji, Kanchi; Singh, Ashutosh Pratap; Rakesh, V.; Rajagopalan, C.; Murugan, S.

    2016-01-01

    In nuclear power plants (NPPs), robotic devices are widely used for carrying out in-service inspection (lSI) and repair tasks at elevated temperatures and radiation environments. These devices comprises servo motors that are powered and controlled by the motion control unit/electric drives. The control and inspection data are to be transmitted back from the inspection device to the control unit using separate industrial graded data transmission cables compatible for high temperature applications. This increases complexity of robot trailing cables and cost. Hence, it is proposed to use power cables that are used for powering the motor for sending information signals using power line communication (PLC) technology. The domestically used PLC modems adds noise to the information signal when coupled on to the motor feed cables during IGBT switching. Therefore, passive low pass filters are used at the motor drive end to reduce the impulsive noise. The aim of this study is to compare noise characteristics for different type of filter structures over pulse width modulation (PWM) network. We will highlight the choice of cut off frequency of filter based on frequency of information signal

  4. Design and implementation of channel estimation for low-voltage power line communication systems based on OFDM

    Zhao Huidong; Hei Yong; Qiao Shushan; Ye Tianchun

    2012-01-01

    An optimized channel estimation algorithm based on a time-spread structure in OFDM low-voltage power line communication (PLC) systems is proposed to achieve a lower bit error rate (BER). This paper optimizes the best maximum multi-path delay of the linear minimum mean square error (LMMSE) algorithm in time-domain spread OFDM systems. Simulation results indicate that the BER of the improved method is lower than that of conventional LMMSE algorithm, especially when the signal-to-noise ratio (SNR) is lower than 0 dB. Both the LMMSE algorithm and the proposed algorithm are implemented and fabricated in CSMC 0.18 μm technology. This paper analyzes and compares the hardware complexity and performance of the two algorithms. Measurements indicate that the proposed channel estimator has better performance than the conventional estimator.

  5. Communication with diode laser: short distance line of sight communication using fiber optics

    Mirza, A.H.

    1999-01-01

    The objective of this project is to carry audio signal from transmitting station to a short distance receiving station along line of sight and also communication through fiber optics is performed, using diode laser light as carrier. In this project optical communication system, modulation techniques, basics of laser and causes of using diode laser are discussed briefly. Transmitter circuit and receiver circuit are fully described. Communication was performed using pulse width modulation technique. Optical fiber communication have many advantages over other type of conventional communication techniques. This report contains the description of optical fiber communication and compared with other communication systems. (author)

  6. Towards Designing PLC Networks for Ubiquitous Connectivity in Enterprises

    Ali, Kamran; Pefkianakis, Ioannis; Liu, Alex X.; Kim, Kyu-Han

    2016-01-01

    Powerline communication (PLC) provides inexpensive, secure and high speed network connectivity, by leveraging the existing power distribution networks inside the buildings. While PLC technology has the potential to improve connectivity and is considered a key enabler for sensing, control, and automation applications in enterprises, it has been mainly deployed for improving connectivity in homes. Deploying PLCs in enterprises is more challenging since the power distribution network is more com...

  7. PLC Berbasis Mikrokontroler Atmega16 Sebagai Pengganti PLC Konvensional

    Brama, Adi; Kurniawan, Syafi’i Agus; Djaohar, Mochammad

    2015-01-01

    Making the research aims to design and build a PLC (Programmable Logic Controller) that uses a microcontroller ATmega16 as the brain of the Micro PLC system. The process of manufacture, testing is done in simulation tools at Pustikom State University of Jakarta and completed the process in May-June 2015. PLC Microcontroller ATmega16-Based As Substitute Conventional PLC, and use the application on a laptop LDmicro to make instructions that form the ladder program to run the output in the form ...

  8. Development of a PLC modem for data transmission over a PWM power supply

    Batard, Christophe; Ginot, Nicolas; Mannah, Marc Anthony; Millet, Christophe; Poitiers, Frédéric

    2014-04-01

    In variable-speed electrical drive and online conditioning monitoring, a feedback loop is required in order to transmit the sensor information from the motor to the controller close to the inverter. Additional cabling is used for signalling. This extra cabling has a significant cost and data transmission may not be reliable. Thus, the use of power line communication (PLC) technology to transmit data in motor drive application is quite interesting. The use of a PLC modem dedicated to the home network in a three-phase inverter-fed motor power cable does not work. Therefore, specific coupling interfaces are developed to transmit data through a pulse-width modulated power supply. Laboratory tests have shown that the couplers are operating properly. They ensure reliable data transmission in a motor drive application.

  9. Enhanced Operation of Electricity Distribution Grids Through Smart Metering PLC Network Monitoring, Analysis and Grid Conditioning

    Iker Urrutia

    2013-01-01

    Full Text Available Low Voltage (LV electricity distribution grid operations can be improved through a combination of new smart metering systems’ capabilities based on real time Power Line Communications (PLC and LV grid topology mapping. This paper presents two novel contributions. The first one is a new methodology developed for smart metering PLC network monitoring and analysis. It can be used to obtain relevant information from the grid, thus adding value to existing smart metering deployments and facilitating utility operational activities. A second contribution describes grid conditioning used to obtain LV feeder and phase identification of all connected smart electric meters. Real time availability of such information may help utilities with grid planning, fault location and a more accurate point of supply management.

  10. Comportamiento de la Tecnología PLC en la Red Eléctrica

    García Guibout, J.; García Garino, Carlos; Fusario, Rubén J.; Castro Lechtaler, Antonio; Sevilla, Guillermo

    2007-01-01

    La tecnología PLC1 - PowerLine Communications- está referida a la transmisión de datos utilizando la red eléctrica, tanto domiciliaria, como la red de distribución de baja tensión. Dependiendo del tipo de red que se utilice como soporte esta tecnología se divide en PLC indoor y outdoor. La primera se refiere a la utilización de la red domiciliaria y utiliza las frecuencias más altas de 5 MHz a 30 ó 40 MHz. La segunda, outdoor, usa la red de distribución y las frecuencias bajas de 1 MHz a 5 ó ...

  11. Experimental Study of 6LoPLC for Home Energy Management Systems

    Augustine Ikpehai

    2016-12-01

    Full Text Available Ubiquitous connectivity is already transforming residential dwellings into smart homes. As citizens continue to embrace the smart home paradigm, a new generation of low-rate and low-power communication systems is required to leverage the mass market presented by energy management in homes. Although Power Line Communication (PLC technology has evolved in the last decade, the adaptation of PLC for constrained networks is not fully charted. By adapting some features of IEEE 802.15.4 and IPv6 over Low-power Wireless Personal Area Network (6LoWPAN into power lines, this paper demonstrates a low-rate, low-power PLC system over the IPv6 network (referred to as 6LoPLC, for Home Energy Management System (HEMS applications. The overall idea is to provide a framework for assessing various scenarios that cannot be easily investigated with the limited number of evaluation hardware available. In this respect, a network model is developed in NS-3 (Version 21 to measure several important characteristics of the designed system and then validated with experimental results obtained using the Hanadu evaluation kits. Following the good agreement between the two, the NS-3 model is utilised to investigate more complex scenarios and various use-cases, such as the effects of impulsive noise, the number of nodes and packet size on the latency and Bit Error Rate (BER performances. We further demonstrate that for different network and application configurations, optimal data sizes exist. For instance, the results reveal that in order to guarantee 99% system reliability, the HEMS application data must not exceed 64 bytes. Finally, it is shown that with impulsive noise in a HEMS network comprising 50 appliances, provided the size of the payload does not exceed 64 bytes, monitoring and control applications incur a maximum latency of 238.117 ms and 248.959 ms, respectively; both of which are within acceptable limits.

  12. Reliability analysis of PLC safety equipment

    Yu, J.; Kim, J. Y. [Chungnam Nat. Univ., Daejeon (Korea, Republic of)

    2006-06-15

    FMEA analysis for Nuclear Safety Grade PLC, failure rate prediction for nuclear safety grade PLC, sensitivity analysis for components failure rate of nuclear safety grade PLC, unavailability analysis support for nuclear safety system.

  13. Reliability analysis of PLC safety equipment

    Yu, J.; Kim, J. Y.

    2006-06-01

    FMEA analysis for Nuclear Safety Grade PLC, failure rate prediction for nuclear safety grade PLC, sensitivity analysis for components failure rate of nuclear safety grade PLC, unavailability analysis support for nuclear safety system

  14. The effect of bright lines in environmental risk communication

    Wilson, K.N.; Desvousges, W.H.; Smith, K.V.; Payne, J.

    1993-01-01

    Bright lines in environmental risk communication refer to the specific levels at which an environmental risk becomes a serious health threat and action should be taken to mitigate its effects. This study examined the effect of ''bright lines'' in risk communication by emphasizing the radon exposure threshold level of 4 picocuries per liter. Specifically, the authors developed a computer-assisted interview containing bright-line versions of risk information. The bright-line version contained a range of possible radon levels, the corresponding number of estimated lung cancer cases, the relative health risk from radon compared to other health risks, and the EPA guidelines for mitigating levels above 4 picocuries in the home. The non-bright line version was identical to the bright-line version, except it did not include the EPA's mitigation recommendations. Effect measures included respondents' change in perceived risk after reading their materials, intended testing behavior, and advice to their neighbor for a specified radon level either above or below the 4 picocury threshold level. This paper discusses broader policy implications for designing effective risk communication programs

  15. Slovak Electric, Plc., 1997

    1997-06-01

    Slovenske elektrarne, a.s. (Slovak Electric, Plc.) was established on November 1, 1994 as one entity among new entities created as successors to the former Slovensky energeticky podnik. The subject activity is the generation of electric power, operation of transmission 220 kV and 400 kV systems, transit, import, export, and sales of electric power. Besides these activities the company deals with generation, distribution, and sales of heat. The company operates one nuclear power station, three thermal power plants, and thirty hydro power plants. One nuclear Power plant is under construction (state up tu June 1997). On this CD ROM next chapters are presented: (1) The structure of the company; (2) The production Units; (3) The economic power of the company; (4) The operation culture of the company; (5) The strategic plans of the company

  16. Slovak Electric, Plc., 1998

    1997-06-01

    Slovenske elektrarne, a.s. (Slovak Electric, Plc., abbrevation 'SE, a.s.') is the Slovak electricity generating utility, incorporated on November 1, 1994 as one of new companies formed from substantially all of the assets and a legal successor of Slovensky energeticky podnik, s.p., founded on January 1, 1969 in the form of SEP group. From its predecessor, Slovak Electric, Plc., took over generation of power, operation of 220 kV and 400 kV power system, transit, import, export, and sale of electricity. It is also involved in generation, distribution, and sale of heat. At present, SE's share of electriciry sales in the Slovak Republic is 88.47%. Electricity is delivered to three regional distribution companies and directly to several major industrial enterprises. SE, a.s. operates one nuclear power station, three thermal power plants, and 30 hydro power plants. The second nuclear power plant is under construction (state up tu June 1997) and SE is participating in the construction of two hydro power plants and one combined cycle power plant. The efforts of SE, s.a. focus on the generation of power and heat with minimal environmental impacts. Ecology is given priority in the SE, a.s. development programmes. SE's mission is to permanently satisfy customers' needs, for an acceptable price and with minimal environmental impact. On this CD ROM next chapters are presented: (1) The structure of the Company; (2) Production units; (3) The economic power of the Company; (4) The operation culture; (5) The strategic plans of the Company

  17. Transmission Delay Modeling of Packet Communication over Digital Subscriber Line

    Jiri Vodrazka

    2013-01-01

    Full Text Available Certain multimedia and voice services, such as VoIP, IPTV, etc., are significantly delay sensitive and their performance is influenced by the overall transmission delay and its variance. One of the most common solutions used in access networks are xDSL lines, especially ADSL2+ or VDSL2. Although these subscriber lines also use packet communication, there are several differences and mechanisms, which influence their resulting delay. Their delay characteristics are also dependent on the individual settings of each xDSL provider, therefore we decided to investigate this area for typical commercially available lines in Czech Republic. Based on the measured values and experiments with real ADSL2+ lines we also developed a potential modeling method, which is presented in this article as well. The parameters for packet jitter based on the generalized Pareto distribution were modeled.

  18. PLC VVVF Elevator Control System

    Tang, Yujian; Gui, Tianyu

    2016-01-01

    The aim of the thesis is to introduce the PLC VVVF elevator and its control system. The thesis can be divided into three parts. The first part is about the overview of the lift: the kinds of the lift and the structure of the lift, it shows the knowledge about the components and the operating systems of the lift. The second part is about the PLC control system, it’s about the operations of the lift from the introduction about the hardware and software of the PLC control system. And the thi...

  19. 78 FR 54149 - Airworthiness Directives; Rolls-Royce plc (RR) Turbofan Engines

    2013-09-03

    ... Airworthiness Directives; Rolls-Royce plc (RR) Turbofan Engines AGENCY: Federal Aviation Administration (FAA... service information identified in this AD, contact Rolls-Royce plc, Corporate Communications, P.O. Box 31... per hour. Replacement parts are estimated to cost about $2,271 per engine. Based on these figures, we...

  20. 76 FR 65136 - Airworthiness Directives; Rolls-Royce plc (RR) Turbofan Engines

    2011-10-20

    ... Airworthiness Directives; Rolls-Royce plc (RR) Turbofan Engines AGENCY: Federal Aviation Administration (FAA... information identified in this AD, contact Rolls-Royce plc, Corporate Communications, P.O. Box 31, Derby... 8, 2011, to perform the inspection. Costs of Compliance Based on the service information, we...

  1. PLC-controlled cryostats for the BlackGEM and MeerLICHT detectors

    Raskin, Gert; Morren, Johan; Pessemier, Wim; Bloemen, Steven; Klein-Wolt, Marc; Roelfsema, Ronald; Groot, Paul; Aerts, Conny

    2016-08-01

    BlackGEM is an array of telescopes, currently under development at the Radboud University Nijmegen and at NOVA (Netherlands Research School for Astronomy). It targets the detection of the optical counterparts of gravitational waves. The first three BlackGEM telescopes are planned to be installed in 2018 at the La Silla observatory (Chile). A single prototype telescope, named MeerLICHT, will already be commissioned early 2017 in Sutherland (South Africa) to provide an optical complement for the MeerKAT radio array. The BlackGEM array consists of, initially, a set of three robotic 65-cm wide-field telescopes. Each telescope is equipped with a single STA1600 CCD detector with 10.5k x 10.5k 9-micron pixels that covers a 2.7 square degrees field of view. The cryostats for housing these detectors are developed and built at the KU Leuven University (Belgium). The operational model of BlackGEM requires long periods of reliable hands-off operation. Therefore, we designed the cryostats for long vacuum hold time and we make use of a closed-cycle cooling system, based on Polycold PCC Joule-Thomson coolers. A single programmable logic controller (PLC) controls the cryogenic systems of several BlackGEM telescopes simultaneously, resulting in a highly reliable, cost-efficient and maintenance-friendly system. PLC-based cryostat control offers some distinct advantages, especially for a robotic facility. Apart of temperature monitoring and control, the PLC also monitors the vacuum quality, the power supply and the status of the PCC coolers (compressor power consumption and temperature, pressure in the gas lines, etc.). Furthermore, it provides an alarming system and safe and reproducible procedures for automatic cool down and warm up. The communication between PLC and higher-level software takes place via the OPC-UA protocol, offering a simple to implement, yet very powerful interface. Finally, a touch-panel display on the PLC provides the operator with a user-friendly and robust

  2. Numerical modelling of multimode fibre-optic communication lines

    Sidelnikov, O S; Fedoruk, M P [Novosibirsk State University, Novosibirsk (Russian Federation); Sygletos, S; Ferreira, F [Aston University, England, Birmingham, B4 7ET (United Kingdom)

    2016-01-31

    The results of numerical modelling of nonlinear propagation of an optical signal in multimode fibres with a small differential group delay are presented. It is found that the dependence of the error vector magnitude (EVM) on the differential group delay can be reduced by increasing the number of ADC samples per symbol in the numerical implementation of the differential group delay compensation algorithm in the receiver. The possibility of using multimode fibres with a small differential group delay for data transmission in modern digital communication systems is demonstrated. It is shown that with increasing number of modes the strong coupling regime provides a lower EVM level than the weak coupling one. (fibre-optic communication lines)

  3. Connecting programmable logic controllers (PLC) to control and data acquisition a comparison of the JET and Wendelstein 7-X approach

    Hennig, Christine; Kneupner, Klaus; Kinna, David

    2012-01-01

    Highlights: ► We describe 2 ways connecting PLCs to fusion control and data acquisition software. ► At W7-X standardization of the PLC type eases the maintenance of the software. ► At JET PLCs are interfaced with a daemon that hides the PLC specific part. ► There is potential to unify the approaches towards a common fusion PLC interface. - Abstract: The use of programmable logic controllers (PLC) for automation of electromechanical processes is an industrial control system technology. It is more and more in use within the fusion community. Traditionally PLC based systems are operated and maintained using proprietary SCADA systems (supervisory control and data acquisition). They are hardly ever integrated with the fusion control and data acquisition systems. An overview of the state of the art in fusion is given in the article. At JET an inhouse “black box protocol” approach has been developed to communicate with any external system via a dedicated http based protocol. However, a PLC usually cannot be modified to implement this special protocol. Hence, a software layer has been developed that interfaces a PLC by implementing the PLC specific communication part on one side and the black box protocol part on the other side. The software is completely data driven i.e. editing the data structure changes the logic accordingly. It can be tested using the web capability of the black box protocol. Multiple PLC types from different vendors are supported, thus multiple protocols to interface the PLC are in use. Depending on the PLC type and available tools it can be necessary to program the PLC accordingly. Wendelstein 7-X uses another approach. For every single PLC a dedicated communication from and to CoDaC is implemented. This communication is projected (programmed) in the PLC and configurable (data driven) on the CoDaC side. The protocol is UDP based and observed via timeout mechanisms. The use of PLCs for Wendelstein 7-X is standardized. Therefore a single

  4. Connecting programmable logic controllers (PLC) to control and data acquisition a comparison of the JET and Wendelstein 7-X approach

    Hennig, Christine, E-mail: Christine.Hennig@ipp.mpg.de [Max-Planck-Institut fuer Plasmaphysik, Wendelsteinstrasse 1, 17491 Greifswald (Germany); Kneupner, Klaus; Kinna, David [JET-EFDA, Culham Science Centre, OX14 3DB Abingdon (United Kingdom)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer We describe 2 ways connecting PLCs to fusion control and data acquisition software. Black-Right-Pointing-Pointer At W7-X standardization of the PLC type eases the maintenance of the software. Black-Right-Pointing-Pointer At JET PLCs are interfaced with a daemon that hides the PLC specific part. Black-Right-Pointing-Pointer There is potential to unify the approaches towards a common fusion PLC interface. - Abstract: The use of programmable logic controllers (PLC) for automation of electromechanical processes is an industrial control system technology. It is more and more in use within the fusion community. Traditionally PLC based systems are operated and maintained using proprietary SCADA systems (supervisory control and data acquisition). They are hardly ever integrated with the fusion control and data acquisition systems. An overview of the state of the art in fusion is given in the article. At JET an inhouse 'black box protocol' approach has been developed to communicate with any external system via a dedicated http based protocol. However, a PLC usually cannot be modified to implement this special protocol. Hence, a software layer has been developed that interfaces a PLC by implementing the PLC specific communication part on one side and the black box protocol part on the other side. The software is completely data driven i.e. editing the data structure changes the logic accordingly. It can be tested using the web capability of the black box protocol. Multiple PLC types from different vendors are supported, thus multiple protocols to interface the PLC are in use. Depending on the PLC type and available tools it can be necessary to program the PLC accordingly. Wendelstein 7-X uses another approach. For every single PLC a dedicated communication from and to CoDaC is implemented. This communication is projected (programmed) in the PLC and configurable (data driven) on the CoDaC side. The protocol is UDP based and

  5. Evaluation of PLC Channel Capacity and ABER Performances for OFDM-Based Two-Hop Relaying Transmission

    Ezzine, Sana; Abdelkefi, Fatma; Cances, Jean Pierre; Meghdadi, Vahid; Bouallégue, Ammar

    2017-01-01

    Powerline network is recognized as a favorable infrastructure for Smart Grid to transmit information in the network thanks to its broad coverage and low cost deployment. The existing works are trying to improve and adapt transmission techniques to reduce Powerline Communication (PLC) channel attenuation and exploit the limited bandwidth to support high data rate over long distances. Two-hop relaying BroadBand PLC (BB-PLC) system, in which Orthogonal Frequency Division Multiplexing (OFDM) is u...

  6. The Integration of DCS I/O to an Existing PLC

    Sadhukhan, Debashis; Mihevic, John

    2013-01-01

    At the NASA Glenn Research Center (GRC), Existing Programmable Logic Controller (PLC) I/O was replaced with Distributed Control System (DCS) I/O, while keeping the existing PLC sequence Logic. The reason for integration of the PLC logic and DCS I/O, along with the evaluation of the resulting system is the subject of this paper. The pros and cons of the old system and new upgrade are described, including operator workstation screen update times. Detail of the physical layout and the communication between the PLC, the DCS I/O and the operator workstations are illustrated. The complex characteristics of a central process control system and the plan to remove the PLC processors in future upgrades is also discussed.

  7. 76 FR 68663 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines

    2011-11-07

    ...-0755; Directorate Identifier 2010-NE-12-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR... Rolls-Royce plc, Corporate Communications, P.O. Box 31, Derby, England, DE248BJ; phone: 011-44-1332... date and may amend this proposed AD based on those comments. We will post all comments we receive...

  8. Peculiarities of Communicative Style in The Advertisement Genre in English and Russian University On-line Communication Discourse Analysis

    Милана Евгеньевна Куприянова

    2014-12-01

    Full Text Available Intercultural communicative competence is one of the integral parts of translators’ skills. The article analyses national and cultural peculiarities of English and Russian communicative styles in the advertisement speech genre in university on-line communication to address the problem of translatability of lexical units. Furthermore, the study explains the use of particular linguistic means and communication strategies as related to the specific features of Anglo-Saxon and Russian linguistic cultures.

  9. The PLC: a logical development

    Walker, Mark; Bissell, Christopher; Monk, John

    2010-01-01

    Programmable Logic Controllers (PLCs) have been used to control industrial processes and equipment for over 40 years, having their first commercially recognised application in 1969. Since then there have been enormous changes in the design and application of PLCs, yet developments were evolutionary rather than radical. The flexibility of the PLC does not confine it to industrial use and it has been used for disparate non-industrial control applications . This article reviews the history, deve...

  10. Equity valuation of Tesco Plc.

    Schmitz, Clemens

    2015-01-01

    This dissertation aimed to value the British retailer Tesco Plc. The objective was to determine a target price for the company and as a consequence determine a buy or sell recommendation when comparing it to the current market price. After the state of the art of literature regarding equity valuation has been assessed, the retail industry as well as Tesco have been analysed in more detail. Based on this, the retail business of Tesco has been valued using the Adjusted Present Va...

  11. Fuzzy logic controller to improve powerline communication

    Tirrito, Salvatore

    2015-12-01

    The Power Line Communications (PLC) technology allows the use of the power grid in order to ensure the exchange of data information among devices. This work proposes an approach, based on Fuzzy Logic, that dynamically manages the amplitude of the signal, with which each node transmits, by processing the master-slave link quality measured and the master-slave distance. The main objective of this is to reduce both the impact of communication interferences induced and power consumption.

  12. 375-nm ultraviolet-laser based non-line-of-sight underwater optical communication

    Sun, Xiaobin; Cai, Wenqi; Alkhazragi, Omar; Ooi, Ee-Ning; He, Hongsen; Chaaban, Anas; Shen, Chao; Oubei, Hassan M.; Khan, Mohammed Zahed Mustafa; Ng, Tien Khee; Alouini, Mohamed-Slim; Ooi, Boon S.

    2018-01-01

    For circumventing the alignment requirement of line-of-sight (LOS) underwater wireless optical communication (UWOC), we demonstrated a non-line-of-sight (NLOS) UWOC link adequately enhanced using ultraviolet (UV) 375-nm laser. Path loss was chosen

  13. Integration of the HVCM PLC into the PEFP Control System

    Song, Young Gi; Jang, Ji Ho; Kwon, Hyeok Jung; Cho, Yong Sub

    2011-01-01

    The High Voltage Converter Modulators (HVCM) for the 100-MeV accelerator was installed to drive the 20-MeV linac. There are two klystrons in the 20-MeV linac and one modulator was used to drive two klystrons simultaneously. The HVCM for the 20-MeV linac area in Korea Atomic Energy Research Institute (KAERI) is shown in Fig. 1. We were faced with the necessity of integrating Programmable Logic Controllers (PLCs) for the HVCM into the Proton Engineering Frontier Project (PEFP) control system. At the PEFP, Experimental Physics and Industrial Control System (EPICS) has become the most widely used solution for building control systems for 100MeV proton accelerator. The EPICS as a standard development tool is a distributed architecture that provides several solutions such as independent programming tools for operating system, operator interface tools, and archiving tools. Although EPICS is used directly in our control system, HVCMs were delivered with the Allen-Bradley ControlLogix as a PLC. The industrial PLC has been verified for safety systems. We need to connect an interface from our EPICS control system to AB-PLC using Ethernet/IP (ControlNet over Ethernet) protocol over Ethernet. In this paper, we will present the communication protocol and EPICS IOC installation for the EPICS based PLC control system

  14. Bit rate maximization for multicast LP-OFDM systems in PLC context

    Maiga , Ali; Baudais , Jean-Yves; Hélard , Jean-François

    2009-01-01

    ISBN: 978-88-900984-8-2.; International audience; In this paper, we propose a new resource allocation algorithm based on linear precoding technique for multicast OFDM systems. Linear precoding technique applied to OFDM systems has already proved its ability to significantly increase the system throughput in a powerline communication (PLC) context. Simulations through PLC channels show that this algorithm outperforms the classical multicast method (up to 7.3% bit rate gain) and gives better pe...

  15. Usage of Wifi Technology for PLC Programming

    Jaromír ŠKUTA

    2009-06-01

    Full Text Available This contribution describes usage of WIFI technology for programming and parameterization of application in PLC. INSYS WLAN unit from the Microelectronics INSYS Corporation is the base of application. Software access point with using USB WIFI component WL167 is running in industrial PC. Particular PC clients are connecting into network infrastructure PLC by the help of this access point and INSYS WLAN unit. This connection allows configuring and uploading program into this PLC.

  16. A Fractional Lower Order Statistics-Based MIMO Detection Method in Impulse Noise for Power Line Channel

    CHEN, Z.

    2014-11-01

    Full Text Available Impulse noise in power line communication (PLC channel seriously degrades the performance of Multiple-Input Multiple-Output (MIMO system. To remedy this problem, a MIMO detection method based on fractional lower order statistics (FLOS for PLC channel with impulse noise is proposed in this paper. The alpha stable distribution is used to model impulse noise, and FLOS is applied to construct the criteria of MIMO detection. Then the optimal detection solution is obtained by recursive least squares algorithm. Finally, the transmitted signals in PLC MIMO system are restored with the obtained detection matrix. The proposed method does not require channel estimation and has low computational complexity. The simulation results show that the proposed method has a better PLC MIMO detection performance than the existing ones under impulsive noise environment.

  17. Control Systems of Rubber Dryer Machinery Components Using Programmable Logic Control (PLC)

    Hendra; Yulianto, A. S.; Indriani, A.; Hernadewita; Hermiyetti

    2018-02-01

    Application of programmable logic control (PLC) is widely used on the control systems in the many field engineering such as automotive, aviation, food processing and other industries [1-2]. PLC is simply program to control many automatic activity, easy to use, flexible and others. PLC using the ladder program to solve and regulated the control system component. In previous research, PLC was used for control system of rotary dryer machine. In this paper PLC are used for control system of motion component in the rubber dryer machinery. Component of rubber dryer machine is motors, gearbox, sprocket, heater, drying chamber and bearing. Principle working of rubber dryer machinery is wet rubber moving into the drying chamber by sprocket. Sprocket is driven by motors that conducted by PLC to moving and set of wet rubber on the drying chamber. Drying system uses greenhouse effect by making hanger dryer design in the form of line path. In this paper focused on motion control system motors and sensors drying rubber using PLC. The results show that control system of rubber dryer machinery can work in accordance control input and the time required to dry the rubber.

  18. Parameters Evaluation of PLC Dependability and Safety

    Juraj Zdansky

    2006-01-01

    Full Text Available This paper is focused on evaluation of dependability and safety parameters of PLC (Programmable Logic Controller. Achievement of requested level of these parameters is an application assumption for using PLC in control of safety critical processes. Evaluation of these parameters can be made on the base of suitable model and it can be influenced by system architecture when necessary.

  19. Application of PLC in irradiation controlling system

    Qin Wenjuan; Lin Baoling; Wang Mingtao; Huang Daorong; Yao Qiuguo; Gao Weixiang; Yang Kun; Xue Changlin; Pu Jiangling

    2005-01-01

    To deal with the multiprogramming controlling system and computer gathering and printing measure data in Irradiation Station, we adopted Programmable Logic Controller (brief: PLC) instead of PCB to control Irradiation System. PLC improved the anti-jamming ability and debugged for convenience. (authors)

  20. A Classification of PLC Models and Applications

    Mader, Angelika H.; Boel, R.; Stremersch, G.

    In the past years there is an increasing interest in analysing PLC applications with formal methods. The first step to this end is to get formal models of PLC applications. Meanwhile, various models for PLCs have already been introduced in the literature. In our paper we discuss several

  1. Short communication: Impact of Line 1 germplasm on South African ...

    Cattle with recorded performance data in South Africa were mated with Line 1 Hereford sires in silico and inbreeding coefficients were calculated for the resulting progeny. The relationship between South African and Line 1 Hereford cattle populations was estimated as twice the maximum inbreeding coefficient for the ...

  2. Analysis of Microstrip Line Fed Patch Antenna for Wireless Communications

    Singh Ashish

    2017-11-01

    Full Text Available In this paper, theoretical analysis of microstrip line fed rectangular patch antenna loaded with parasitic element and split-ring resonator is presented. The proposed antenna shows that the dualband operation depends on gap between parasitic element, split-ring resonator, length and width of microstrip line. It is found that antenna resonates at two distinct resonating modes i.e., 0.9 GHz and 1.8 GHz for lower and upper resonance frequencies respectively. The antenna shows dual frequency nature with frequency ratio 2.0. The characteristics of microstrip line fed rectangular patch antenna loaded with parasitic element and split-ring resonator antenna is compared with other prototype microstrip line fed antennas. Further, the theoretical results are compared with simulated and reported experimental results, they are in close agreement.

  3. Error statistics in a high-speed fibreoptic communication line with a phase shift of odd bits

    Shapiro, Elena G

    2009-01-01

    The propagation of optical pulses through a fibreoptic communication line with a phase shift of odd bits is directly numerically simulated. It is shown that simple analytic expressions approximate well the error probability. The phase shift of odd bits in the initial sequence is statistically shown to decrease significantly the error probability in the communication line. (fibreoptic communication lines)

  4. Statistical simulation of information transfer through non-line-of-sight atmospheric optical communication channels

    Tarasenkov, M. V.; Belov, V. V.; Poznakharev, E. S.

    2017-11-01

    Impulse response of non-line-of-sight atmospheric communication channels at wavelengths of 0.3, 0.5, and 0.9 μm are compared for the case in which the optical axes of the receiver and laser radiation lie in the plane perpendicular to the Earth's surface. The most efficient communication channel depending on the base distance is determined. For a wavelength of 0.5 μm and a concrete variant of the transceiving part of the communication system, the limiting communication range and the limiting repetition frequency of pulses that can be transmitted through the communication channel are estimated.

  5. PLC control of 50 MW klystron modulators

    Shang Lei; Liu Gongfa; Chen Liping; Lu Yeming; Hong Jun; Zhang Yi; Zhao Feng

    2004-01-01

    Upgrade project of the 50 MW klystron modulators of Hefei Light Source (HLS) was firstly introduced. PLC control system of modulators was employed to replace the old control and monitor system, which was based on relay logic circuit and manual operation method. the PLC system becomes a sub system of the new EPICS control system of HLS. Constant-current, switch-mode and high voltage power supplies were adopted to replace the old 50 Hz power supplies. The technology of modulators was improved and operation was more reliable. The design method, hardware and software of PLC control of modulators were described and the performance was presented. (authors)

  6. Proceedings of the 9. international symposium on power-line communications and its applications

    Lampe, L. (comp.) [British Columbia Univ., Vancouver, BC (Canada). Dept. of Electrical and Computer Engineering

    2005-07-01

    The 2005 International Symposium on Power Line Communications and Its Applications (ISPLC 2005) is the leading international scientific conference on technology and applications for communication over power lines. The conference addresses the latest technological advances in power-line communications and current and future applications of power-line communication systems including broadband Internet access, indoor home networking, power-line based communications in vehicles, power-line control networks, and automatic meter reading systems. Specific conference papers included measurements, channel characterization and modeling; standards and regulations; electromagnetic compatibility; information and communication theory; modulation and error-control coding techniques; single carrier, OFDM, and spread spectrum techniques; detection, estimation, and iterative processing techniques; signal processing algorithms and devices; multiple-access techniques; modem and LSI design; networks and protocols; system architectures; automatic meter reading systems; applications and services; and, experimental systems and field trials. A total of 90 papers were featured and organized into 14 regular sessions and one poster session. Seven of these presentations have been catalogued separately for inclusion in this database. In addition to the technical program, 3 keynotes speeches and 2 panel discussions were presented and chaired by distinguished speakers and moderators. tabs., figs.

  7. Application of PLC to mine hoist

    Zheng Liquan

    2003-01-01

    This paper describes the reform of the hoister JMK 1.85 x 4 (B) with programmable logic controller (PLC), introduces hardware architecture, software architecture and interference protection measures, and presents the existential problems and suggestions for improvement

  8. Automated Formal Verification for PLC Control Systems

    Fernández Adiego, Borja

    2014-01-01

    Programmable Logic Controllers (PLCs) are widely used devices used in industrial control systems. Ensuring that the PLC software is compliant with its specification is a challenging task. Formal verification has become a recommended practice to ensure the correctness of the safety-critical software. However, these techniques are still not widely applied in industry due to the complexity of building formal models, which represent the system and the formalization of requirement specifications. We propose a general methodology to perform automated model checking of complex properties expressed in temporal logics (e.g. CTL, LTL) on PLC programs. This methodology is based on an Intermediate Model (IM), meant to transform PLC programs written in any of the languages described in the IEC 61131-3 standard (ST, IL, etc.) to different modeling languages of verification tools. This approach has been applied to CERN PLC programs validating the methodology.

  9. Using of Finite Automation at Programming PLC

    Karol Rastocny

    2004-01-01

    Full Text Available The paper is concerning with systematic advances at programming programmable logic controllers (PLC, which comes out from algebraic description of behaviour of sequential circuit, in the way of finite automaton. This kind of access is streamlining the work of a programmer and enabling to use formalisms in the of whole process of system development, that is from process of analysing demands to process of verification and validation created program. The paper considers about using of ladder diagram at programming PLC.

  10. 77 FR 37740 - Stagecoach Group plc and Coach USA, Inc., et al.-Acquisition of Control of Assets-American Coach...

    2012-06-22

    ... Application. SUMMARY: On May 25, 2012, Stagecoach Group plc (Stagecoach), a noncarrier, and a number of its... Group plc and Coach USA, Inc., et al.--Acquisition of Control of Assets--American Coach Lines of Atlanta...) filed an application under 49 U.S.C. 14303 to acquire control of the assets of ten separate interstate...

  11. Design and Implementation of an over Current Protection Laboratory for Electrical Power Transmission Systems Based on PLC Techniques

    Hassaan Th. H. Thabet

    2018-01-01

    Full Text Available This paper describes a modern approach for the protection of transmission lines to ensure theirsafety against the faults occurred in power systems. Our approach uses a Programmable LogicController (PLC to realize a transmission line as an over current protection relay. A conditioningcircuit was designed, implemented and tested to collect data obtained from Hall Effect sensors which convert them to suitable analog values compatible with PLC's inputs. Results obtained by our PLC control system are very similar to those obtained by the conventional relays but more efficient. An Automatic Reclosing System (ARS for remote faults is also included in this approach. Our PLC control system and its algorithm are illustrated in this paper also. This approach is designed to be used in electrical networks laboratories as an educational unit in electrical departments of engineering collages and technical institutes; it can be used also in real power systems through suitable interfacing facilities.

  12. Two-channel spin-chain communication line and simple quantum gates

    Stolze, J.; Zenchuk, A. I.

    2017-08-01

    We consider the remote creation of a mixed state in a one-qubit receiver connected to two two-qubit senders via different channels. Channels are assumed to be chains of spins (qubits) with nearest-neighbor interactions, no external fields are being applied. The problem of sharing the creatable region of the receiver's state-space between two senders is considered for a communication line with the receiver located asymmetrically with respect to these senders (asymmetric communication line). An example of a quantum register realizing simple functions is constructed on the basis of a symmetric communication line. In that setup, the initial states of the two senders serve as input and control signals, respectively, while the state of the receiver at a proper time instant is considered as the output signal.

  13. Evaluation of Communication Network State Estimators for Adaptive Power-Balancing

    Findrik, Mislav; Pedersen, Rasmus; Sloth, Christoffer

    2017-01-01

    Smart Grid applications are going to reach the LV grid assets and households in order to efficiently use the resources in distribution grids. A cost effective way to connect these devices is to utilize the existing network infrastructure or to utilize Power-Line Com- munication (PLC). In this work...... we have show how PLC communication can have significant impairments for load-frequency control operations in the microgrid. Moreover, we have demonstrate how such poor network performance can influence the control performance on a case study of the low voltage grid controller. Further- more, we have...

  14. MCD 80: A modular coupling system for power line carrier transmission

    Fischer, B; Mayer, M

    1983-05-01

    Power line carrier (PLC) links are of great importance to power supply utilities. The communications equipment is linked to the H.V. system by a coupling device. Brown Boveri have developed a new modular coupling system MCD 80 which is compact, programmable and economical. The benefit of years of experience in the field went into its development. With the new system, optimum PLC couplings, R.F. through-connections and junction networks are possible for all H.V. transmission systems. A general look at the subject of PLC couplings is followed by a closer look at the main components, such as the programmable high pass coupling unit, band pass coupling unit, hybrid, separating filter, R.F. junction network and attenuator. Some typical examples are described.

  15. Enhancing communication skills for pediatric visits through on-line training using video demonstrations

    Wissow Larry

    2008-02-01

    Full Text Available Abstract Background Training in communication skills for health professionals is important, but there are substantial barriers to individual in-person training for practicing clinicians. We evaluated the feasibility and desirability of on-line training and sought suggestions for future courses. Methods Based on successful in-person curricula for communication skills and our previous on-line curricula, we created an on-line course consisting of 28 modules (4.75 hours CME credit about communication skills during pediatric visits that included a mental health concern; each module included a brief case, a multiple choice question, an explanation, and a 1–2 minute video demonstrating key skills. Specific communication skills included: greeting, setting an agenda, discussing diagnosis and treatment, and managing negative interactions. The course was announced by emails in spring, 2007; the course was available on-line for 60 days; we aimed to enroll 50 clinicians. Outcomes were analyzed for those who evaluated the course within 75 days of its initial availability. Results Overall, 61 clinicians registered, of whom most were nurses (N = 24, physicians (N = 22, or psychologists or social workers (N = 12. Of the 36 (59% clinicians who evaluated the course, over 85% agreed that all course objectives had been met; over 90% reported greater confidence in greetings and agenda-setting; and over 80% reported greater confidence in discussing diagnosis and treatment and managing negative interactions. Nearly all, 97% would recommend the course to other clinicians and trainees. Suggestions for improvement included a library of additional video vignettes and written materials to accompany the on-line training. Conclusion On-line training in communication skills for pediatric mental health visits is feasible, desirable and associated with increased confidence in key skills. Positive feedback from clinicians suggests that a comparison of on-line versus in

  16. THROUGH-THE-EARTH (TTE) COMMUNICATIONS SYSTEM AND THE IN-MINE POWER LINE (IMPL) COMMUNICATIONS SYSTEM

    Zvi H. Meiksin

    2002-01-01

    Work has progressed on both subsystems: the Through-the-Earth (TTE) Communications system and the In-Mine Power Line (IMPL) Communications system. The TTE system: The system was fabricated and repackaged as an industrial product enclosed in a commercial rugged, waterproof housing suitable for installation in mines. Features were added to the system to appeal to the preferences of different mine managers. Arrangements were made with NIOSH to install the system in the Lake Lynn underground mine for evaluation and demonstration to potential users. The IMPL system: Voice compression was successfully implemented and incorporated into the laboratory model. Compressed voice was transmitted through a power line, expanded at the receiving end, and received with high clarity

  17. Development of Safety Grade PLC (POSAFE-Q) and Performance Test Results

    Kim, Chang Hwoi; Park, Won Man; Choi, Jong Gyun; Lee, Dong Young [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); No, Young Hun; Song, Seung Hwan [POSCON, Seoul (Korea, Republic of)

    2006-07-01

    The safety grade PLC (POSAFE-Q) is being developed in the Korea Nuclear Instrumentation and Control System (KNICS) R and D project. The PLC satisfies Safety Class 1E, Quality Class 1, and Seismic Category I. The software such as the RTOS and firmware are being developed according to the safety critical software life cycle. Especially, the formal method is applied to design the SRS (Software Requirement Spec.) and the SDS (Software Design Specification.) to be error-free. The POSAFE-Q has several modules such as processor module, input and output modules, communication modules, redundant processor module, redundant power modules, etc,. To verify the function and performance, several tests such as CT, IT and ST were performed. And also, the equipment qualification test for environment, EMI and EMC, and seismic ware performed. All tests are satisfied with the requirements and specification for safety grade PLC, and the criteria for safety system in nuclear power plants.

  18. Technical considerations for the development of an engineering safety features control system with PLC

    Lee, C. K.; Kim, C. H.; Han, J. B.; Kim, H.; Lee, S. S.

    2002-01-01

    Technical considerations are summarized for the development of an ESFCS(Engineered Safety Features Control System) with PLC (Programmable Logic Controller). The ESFCS is required for the mitigation of plant accident conditions and therefore developed in conformance with the design requirements applied to the safety critical system. The design of ESFCS primarily considered its safety, and the system has an architecture that will be able to minimize spurious actuation. The PLC based functional distribution and redundant design features are adopted, and the fieldbus is applied in the communication of information and control signals between PLC processors. It is expected that the ESFCS will have several advanced design features compared with the conventional systems supplied by foreign vendors

  19. Development of Safety Grade PLC (POSAFE-Q) and Performance Test Results

    Kim, Chang Hwoi; Park, Won Man; Choi, Jong Gyun; Lee, Dong Young; No, Young Hun; Song, Seung Hwan

    2006-01-01

    The safety grade PLC (POSAFE-Q) is being developed in the Korea Nuclear Instrumentation and Control System (KNICS) R and D project. The PLC satisfies Safety Class 1E, Quality Class 1, and Seismic Category I. The software such as the RTOS and firmware are being developed according to the safety critical software life cycle. Especially, the formal method is applied to design the SRS (Software Requirement Spec.) and the SDS (Software Design Specification.) to be error-free. The POSAFE-Q has several modules such as processor module, input and output modules, communication modules, redundant processor module, redundant power modules, etc,. To verify the function and performance, several tests such as CT, IT and ST were performed. And also, the equipment qualification test for environment, EMI and EMC, and seismic ware performed. All tests are satisfied with the requirements and specification for safety grade PLC, and the criteria for safety system in nuclear power plants

  20. An advanced lab frame PC-PLC regime for a power supply control

    Abdel-Bary, M

    2010-01-01

    A lab frame automatic control system (LFACS) based on a programmable logic controller (PLC) is designed, developed and tested in the laboratory. The LFACS is designed to control and monitor one DC power supply with output current accuracy 0.001 amps, one automatic valve. Also the LFACS will monitor one full range vacuum measurement and one water leak detector. The control system is built based on the internationally standard programmable logic controller (PLC) from Siemens. Two software's have been used; firstly SIMATIC S 7 lite has been used to build the control program and safety interlocks, secondly winCC flexible (runs in a PC computer and communicates with the PLC by multi point interface PC adapter (MPI) has been used to build the user-machine interface . This lab frame control system will be generalized to a global control system to control the MGC-20 cyclotron. The lab tests showed a reliable and flexible control system.

  1. Communication Characteristics of Faulted Overhead High Voltage Power Lines at Low Radio Frequencies

    Nermin Suljanović

    2017-11-01

    Full Text Available This paper derives a model of high-voltage overhead power line under fault conditions at low radio frequencies. The derived model is essential for design of communication systems to reliably transfer information over high voltage power lines. In addition, the model can also benefit advanced systems for power-line fault detection and classification exploiting the phenomenon of changed conditions on faulted power line, resulting in change of low radio frequency signal propagation. The methodology used in the paper is based on the multiconductor system analysis and propagation of electromagnetic waves over the power lines. The model for the high voltage power line under normal operation is validated using actual measurements obtained on 400 kV power line. The proposed model of faulted power lines extends the validated power-line model under normal operation. Simulation results are provided for typical power line faults and typical fault locations. Results clearly indicate sensitivity of power-line frequency response on different fault types.

  2. Error statistics during the propagation of short optical pulses in a high-speed fibreoptic communication line

    Shapiro, E G

    2008-01-01

    Simple analytic expressions are derived to approximate the bit error rate for data transmission through fibreoptic communication lines. The propagation of optical pulses is directly numerically simulated. Analytic estimates are in good agreement with numerical calculations. (fibreoptic communication)

  3. Automated turn pike using PLC and SCADA

    Silpa Sreedhar, P.; Aiswarya, P.; Kathirvelan, J.

    2017-11-01

    We propose a smart turnpike based on Programmable Logic Controller (PLC) and Supervisory Control and Data Acquisition Systems (SCADA) in this paper. In this work, the basic idea is to measure the weight of the vehicles and classify them according to its weight to the respective lanes. It is difficult for the turnpike people to monitor the whole process all the time. So, this PLC based diversion system can be implemented in turnpikes to reduce the difficulties. This method will work based on weight sensors (piezo-resistive) whose output will be fed to a PLC, which will control the vehicle diversion. Using SCADA software, the whole process can be monitored from a remote area. The algorithm developed in this successfully installed in real time system.

  4. Evaluation of PLC Channel Capacity and ABER Performances for OFDM-Based Two-Hop Relaying Transmission

    Sana Ezzine

    2017-01-01

    Full Text Available Powerline network is recognized as a favorable infrastructure for Smart Grid to transmit information in the network thanks to its broad coverage and low cost deployment. The existing works are trying to improve and adapt transmission techniques to reduce Powerline Communication (PLC channel attenuation and exploit the limited bandwidth to support high data rate over long distances. Two-hop relaying BroadBand PLC (BB-PLC system, in which Orthogonal Frequency Division Multiplexing (OFDM is used, is considered in this paper. We derive and compare the PLC channel capacity and the end-to-end Average BER (ABER for OFDM-based direct link (DL BB-PLC system and for OFDM-based two-hop relaying BB-PLC system for Amplify and Forward (AF and Decode and Forward (DF protocols. We analyze the improvements when we consider the direct link in a cooperative communication when the relay node only transmits the correctly decoded signal. Maximum ratio combining is employed at the destination node to detect the transmitted signal. In addition, in this paper, we highlight the impact of the relay location on the channel capacity and ABER for AF and DF transmission protocols. Moreover, an efficient use of the direct link was also investigated in this paper.

  5. A Study on the Optimal Receiver Impedance for SNR Maximization in Broadband PLC

    Massimo Antoniali

    2013-01-01

    Full Text Available We consider the design of the front-end receiver for broadband power line communications. We focus on the design of the input impedance that maximizes the signal-to-noise ratio (SNR at the receiver. We show that the amplitude, rather than the power, of the received signal is important for communication purposes. Furthermore, we show that the receiver impedance impacts the amplitude of the noise term. We focus on the background noise, and we propose a novel description of the noise experienced at the receiver port of a PLC network. We model the noise as the sum of four uncorrelated contributions, that is, the active, resistive, receiver, and coupled noise components. We study the optimal impedance design problem for real in-home grids that we assessed with experimental measurements. We describe the results of the measurement campaign, and we report the statistics of the optimal impedance. Hence, we study the best attainable performance when the optimal receiver impedance is deployed. We focus on the SNR and the maximum achievable rate, and we show that power matching is suboptimal with respect to the proposed impedance design approach.

  6. Empirical P-L-C relations for delta Scuti stars

    Gupta, S.K.

    1978-01-01

    Separate P-L-C relations have been empirically derived by sampling the delta Scuti stars according to their pulsation modes. The results based on these relations have been compared with those estimated from the model based P-L-C relations and the other existing empirical P-L-C relations. It is found that a separate P-L-C relation for each pulsation mode provides a better correspondence with observations. (Auth.)

  7. Synchronization and bidirectional communication without delay line using strong mutually coupled semiconductor lasers

    Li, Guang-Hui; Wang, An-Bang; Feng, Ye; Wang, Yang

    2010-07-01

    This paper numerically demonstrates synchronization and bidirectional communication without delay line by using two semiconductor lasers with strong mutual injection in a face-to-face configuration. These results show that both of the two lasers' outputs synchronize with their input chaotic carriers. In addition, simulations demonstrate that this kind of synchronization can be used to realize bidirectional communications without delay line. Further studies indicate that within a small deviation in message amplitudes of two sides (±6%), the message can be extracted with signal-noise-ratio more than 10 dB; and the signal-noise-ratio is extremely sensitive to the message rates mismatch of two sides, which may be used as a key of bidirectional communication.

  8. Synchronization and bidirectional communication without delay line using strong mutually coupled semiconductor lasers

    Guang-Hui, Li; An-Bang, Wang; Ye, Feng; Yang, Wang

    2010-01-01

    This paper numerically demonstrates synchronization and bidirectional communication without delay line by using two semiconductor lasers with strong mutual injection in a face-to-face configuration. These results show that both of the two lasers' outputs synchronize with their input chaotic carriers. In addition, simulations demonstrate that this kind of synchronization can be used to realize bidirectional communications without delay line. Further studies indicate that within a small deviation in message amplitudes of two sides (±6%), the message can be extracted with signal-noise-ratio more than 10 dB; and the signal-noise-ratio is extremely sensitive to the message rates mismatch of two sides, which may be used as a key of bidirectional communication. (general)

  9. The application of PLC in 60Co container inspection system

    Huang Yibin; Xiang Xincheng

    2001-01-01

    The author discusses the interlock technique of 60 Co container inspection system, and introduces the hardware structure and program of interlock control system using PLC. Due to adopting PLC distributed control, the system works stably and reliably. The successful application of PLC in 60 Co container inspection system has some use for reference in nuclear technology field

  10. Amersham International plc. Report and Accounts 1995

    1995-01-01

    The Annual Report and Accounts for Amersham International plc for the year 1995 are presented. This leading health science company develops products, services and technologies based on its expertise in labelling and detection at the molecular level. Recent work in the fields of life science research, nuclear medicine and industrial quality and safety assurance are described. (UK)

  11. Enhancing the performance of mine communication, warning and condition monitoring systems

    Myszkowski, M.; Rellecke, R.; Widera, K. (and others) [DMT GmbH, Essen (Germany)

    2008-07-01

    This project investigated improvements in power line communications (PLC), condition monitoring techniques and diagnostic aids, together with improving audible communication systems underground. The work on PLC investigated narrow-band, low data rate technologies and high data bandwidth broadband PLC technologies. It is concluded that broadband PLC technologies cannot currently meet the requirements of providing backbone communications in mining and that fibre-optic methods offer better performance. However, short range broadband applications are feasible and an innovative voice and data transmission system, including remote control features, has been developed for coalface communications, using radiofrequency and digital voice technologies not previously used for this application. This system accommodates all the new digital interfaces: Bluetooth, PLC, twisted pair cables, etc. The condition monitoring research has led to a suite of new specialised ATEX-certified sensors together with the development of new vibration signature tracking and classification devices and methods, which provide an early indication of incipient failure. Particular value of these methods is anticipated with coalface equipment. A further component of the work examined the practicability of implementing noise reduction techniques in mining communications systems and noisy workplaces by means of active noise cancellation (ANC). Whilst ANC-based techniques would not be currently cost-effective, several other practical communication improvements are worth considering further. These include new hearing protector technologies and a simple but effective 'waveshape compressor' to improve speech dynamic range in communication systems. A final component of the project examined the issue of mining alerts and alarms, where significant advances in signal design tools have been made. 60 refs., 138 figs., 8 tabs., 1 app.

  12. A combined PLC and CPU approach to multiprocessor control

    Harris, J.J.; Broesch, J.D.; Coon, R.M.

    1995-10-01

    A sophisticated multiprocessor control system has been developed for use in the E-Power Supply System Integrated Control (EPSSIC) on the DIII-D tokamak. EPSSIC provides control and interlocks for the ohmic heating coil power supply and its associated systems. Of particular interest is the architecture of this system: both a Programmable Logic Controller (PLC) and a Central Processor Unit (CPU) have been combined on a standard VME bus. The PLC and CPU input and output signals are routed through signal conditioning modules, which provide the necessary voltage and ground isolation. Additionally these modules adapt the signal levels to that of the VME I/O boards. One set of I/O signals is shared between the two processors. The resulting multiprocessor system provides a number of advantages: redundant operation for mission critical situations, flexible communications using conventional TCP/IP protocols, the simplicity of ladder logic programming for the majority of the control code, and an easily maintained and expandable non-proprietary system

  13. CERN HR receives award for on-line recruitment and communication

    Joannah Caborn Wengler

    2012-01-01

    In a survey of 21,000 European students, CERN ranked 15th, ahead of giants like Microsoft and Nestlé, for the quality of its on-line "talent communication", that is how it uses the Internet to attract job applicants. HR now boasts a new virtual award, certifying its on-line savvy.   The "virtual" award given to HR. How did you get your job at CERN? Via the CERN HR website, or Facebook, or Twitter? Or were you headhunted on LinkedIn? Particularly if you’re from the younger generation, chances are that you used some form of on-line recruitment. In this case you will have used one of the best recruitment tools in Europe, according to the 2012 OTaC (Online Talent Communication) study, carried out by a research institute named Potentialpark. It surveyed over 21,000 students, asking them to rate employers’ use of seven different channels of communication about jobs and careers, from HR websites and on-line application systems to the...

  14. Development of tools for automatic generation of PLC code

    Koutli, Maria; Chasapis, Georgios; Rochez, Jacques

    2014-01-01

    This Master thesis was performed at CERN and more specifically in the EN-ICE-PLC section. The Thesis describes the integration of two PLC platforms, that are based on CODESYS development tool, to the CERN defined industrial framework, UNICOS. CODESYS is a development tool for PLC programming, based on IEC 61131-3 standard, and is adopted by many PLC manufacturers. The two PLC development environments are, the SoMachine from Schneider and the TwinCAT from Beckhoff. The two CODESYS compatible P...

  15. Strategic Lines of Communication in Development of Management and Human Skills

    Rider Antonio Moreno Guillen

    2017-02-01

    Full Text Available The objective of this study is to propose strategic lines of communication in the development of managerial and human skills at the Rural School Nucleus (NER 187, Calderas parish, Bolívar municipality of Barinas state. The nature of the study was embedded in the quantitative paradigm, the type of research in the Feasible Project modality and the research design focused on a field study. The population and the sample were made up of thirty (30 teachers. For the collection of information, a questionnaire survey was designed with Likert scaling with five (05 response alternatives: Always, Almost Always, Sometimes, Almost Never and Never. The study concludes: infrequently the passive communication style is developed for the development of managerial and human skills. They consider that moderately the manager uses aggressive communication style to develop managerial skills. In addition, it lacks the use of assertive communication to develop managerial skills. Likewise, they lack technical skills, human skills and conceptual skills. These are relevant for the proposal of strategic lines in communication because it will accede to the strengthening of the managerial and human abilities of both the teacher and the school manager.

  16. Automation of Underground Cable Laying Equipment Using PLC and Hmi

    Mal Kothari, Kesar; Samba, Vishweshwar; Tania, Kinza; Udayakumar, R., Dr; Karthikeyan, Ram, Dr

    2018-04-01

    Underground cable laying is an alternative for overhead cable laying of telecommunication and power transmission lines. It is becoming very popular in recent times because of some of its advantages over overhead cable laying. This type of cable laying is mostly practiced in developed countries because it is more expensive than overhead cable laying. Underground cable laying is more suitable when land is not available, and it also increases the aesthetics. This paper implements the automation on a manually operated cable pulling winch machine using programmable logic controller (PLC). Winch machines are useful in underground cable laying. The main aim of the project is to replace all the mechanical functions with electrical controls which are operated through a touch screen (HMI). The idea is that the machine should shift between parallel and series circuit automatically based on the pressure sensed instead of manually operating the solenoid valve. Traditional means of throttling the engine using lever and wire is replaced with a linear actuator. Sensors such as proximity, pressure and load sensor are used to provide the input to the system. The HMI used will display the speed, length and tension of the rope being winded. Ladder logic is used to program the PLC.

  17. PLC based development of control, monitoring and interlock for 100 kW, 45.6 MHz ICRH system

    Jadav, Hiralal; Joshi, Rameshkumar; Mali, Aniruddh K.; Kadia; Bhavesh; Parmar; Maganbhai, Kiritkumar; Kulkarni, S.V.

    2015-01-01

    This paper presents details of PLC based system development for 100KW at the rate 45.6 MHz. Presently in ICRH RF DAC (Data acquisition and control) system existing based on real time VME and linux operating system. The ICRH system consists of 1.5 MW RF generator operating at 22- 40MHz which is used for second harmonic heating and pre-ionization experiments on SST-1 Tokamak at 1.5T and 3T magnetic field operation respectively. The task of PLC system in RF ICRH is to control, monitoring and interlocks HVDC power supply signal. Voltage and current signal of 2 kW, 20 kW, tetrode for 100 kW RF tube electrode like Filament, Control grid, Plate, Screen grid, signal monitor and voltage set raised by PLC analog IO module. Acknowledgement of the HVDC supply Filament, Control grid, Plate, Screen grid power supply is monitor and interlocks by PLC Digital IO module to interlocks stop the RF pulse and off HV power supply. The RF pulse(shot) to trigger signal generator (5mw) RF power output feed to LPA then chain of 2 KW, 20 KW, 100 KW at the rate 45.6 MHz. The programming logic controller (PLC) software is written in ladder language for AH500 Delta make using ISP Soft 2.04 and GUI is in the table form to control and monitor the parameters. Communication of PLC to PC by ethernet LAN network. (author)

  18. 375-nm ultraviolet-laser based non-line-of-sight underwater optical communication

    Sun, Xiaobin

    2018-05-04

    For circumventing the alignment requirement of line-of-sight (LOS) underwater wireless optical communication (UWOC), we demonstrated a non-line-of-sight (NLOS) UWOC link adequately enhanced using ultraviolet (UV) 375-nm laser. Path loss was chosen as a figure-of-merit for link performance in this investigation, which considers the effects of geometries, water turbidity, and transmission wavelength. The experiments suggest that path loss decreases with smaller azimuth angles, higher water turbidity, and shorter wavelength due in part to enhanced scattering utilizing 375-nm radiation. We highlighted that it is feasible to extend the current findings for long distance NLOS UWOC link in turbid water, such as harbor water.

  19. Statistics of errors in fibre communication lines with a phase-modulation format and optical phase conjugation

    Shapiro, Elena G; Fedoruk, Mikhail P

    2011-01-01

    Analytical formulas are derived to approximate the probability density functions of 'zero' and 'one' bits in a linear communication channel with a binary format of optical signal phase modulation. Direct numerical simulation of the propagation of optical pulses in a communication line with optical phase conjugation is performed. The results of the numerical simulation are in good agreement with the analytical approximation. (fibreoptic communication lines)

  20. Development of multifunctional radiation monitoring instrument based on PLC technology

    Li Ziqiang; Zhu Yuye; Zhuang Min

    2007-01-01

    This eight-channel multifunctional Radiation Monitoring Instrument is developed by making use of the built-in high-speed counters and the powerful instruction system of the SIEMES SIMATICS S7 series Programmable Logic Controllers (PLC) to record and process the pulse signal output by the detectors. The instrument with functions, such as analog and digital display, digital storage of digital data, pulse signal generator, network communication, can connect various types of pulse detectors. The initial process can be translated between Graduation Apparatus method and Formula method. the logicality of the high-dosage warning system is processed itself. The signal output will drive the alarm lights and bell directly. This paper mainly describes the configuration, programming and feature of the instrument. (authors)

  1. Intelligent Traffic Light Based on PLC Control

    Mei, Lin; Zhang, Lijian; Wang, Lingling

    2017-11-01

    The traditional traffic light system with a fixed control mode and single control function is contradicted with the current traffic section. The traditional one has been unable to meet the functional requirements of the existing flexible traffic control system. This paper research and develop an intelligent traffic light called PLC control system. It uses PLC as control core, using a sensor module for receiving real-time information of vehicles, traffic control mode for information to select the traffic lights. Of which control mode is flexible and changeable, and it also set the countdown reminder to improve the effectiveness of traffic lights, which can realize the goal of intelligent traffic diversion, intelligent traffic diversion.

  2. Event notification system with a PLC

    Kawase, M.; Yoshikawa, Hiroshi; Sakaki, Hironao; Takahashi, Hiroki; Sako, Hiroyuki; Kamiya, Junichiro; Takayanagi, Tomohiro

    2004-01-01

    When an interlock occurs in the equipment, it is required to notify the upper rank control system of the Interlock and receive information for apparatus information in the upper rank control system as at high speed as possible. In the apparatus using FA-M3, it can respond to this by using the notice function of an event. This report shows the event notification system with a PLC based Kicker electromagnet power supply for 3GeV RCS. (author)

  3. PLC Based Automatic Multistoried Car Parking System

    Swanand S .Vaze; Rohan S. Mithari

    2014-01-01

    This project work presents the study and design of PLC based Automatic Multistoried Car Parking System. Multistoried car parking is an arrangement which is used to park a large number of vehicles in least possible place. For making this arrangement in a real plan very high technological instruments are required. In this project a prototype of such a model is made. This prototype model is made for accommodating twelve cars at a time. Availability of the space for parking is detecte...

  4. Increase in Multicast OFDM Data Rate in PLC Network using Adaptive LP-OFDM

    Maiga , Ali; Baudais , Jean-Yves; Hélard , Jean-François

    2009-01-01

    ISBN: 978-1-4244-3523-4; International audience; Linear precoding (LP) technique applied to OFDM systems has already proved its ability to significantly increase the system throughput in a powerline communication (PLC) context. In this paper, we propose resource allocation algorithms based on the LP technique to increase the multicast OFDM systems bit rate. The conventional multicast capacity is limited by the user which experiences the worst channel conditions. To increase the multicast bit ...

  5. PLC based control system for RAM assembly test facility

    Kulkarni, S.S.; Kumar, Vinaya; Chandra, Umesh

    1994-01-01

    The flexibility, expandability, ease of programming and diagnostic features makes the programmable logic controller (PLC) suitable for a variety of control applications in engineering system test facilities. A PLC based control system for RAM assembly test facility (RATF) and for testing the related hydraulic components is being developed and installed at BARC. This paper describes the approach taken for meeting the control requirements and illustrates the PLC software that has been developed. (author). 1 fig

  6. Practical application with plc in manipulation of a robotic arm

    Cristian Barz

    2014-12-01

    Full Text Available This paper presents the use of a robotic arm PLC Siemens in order not using CNC commands. This is done by programming the PLC ladder diagram language that makes movement on the three axes of the arm by means of stepper motors. Required command console PLC is built with the help of a touch screen HMI Weintek. In the user interface are introduced distances and displacement speeds on the three axes.

  7. On Construction and Verification of PLC-Programs

    E. V. Kuzmin

    2012-01-01

    Full Text Available We review some methods and approaches to programming discrete problems for Programmable Logic Controllers on the example of constructing PLC-programs for controling a code lock. For these approaches we evaluate the usability of the model checking method for the analysis of program correctness with respect to the automatic verification tool Cadence SMV. Some possible PLC-program vulnerabilities arising at a number approaches to programming of PLC are revealed.

  8. Knowledge-based engineering of a PLC controlled telescope

    Pessemier, Wim; Raskin, Gert; Saey, Philippe; Van Winckel, Hans; Deconinck, Geert

    2016-08-01

    As the new control system of the Mercator Telescope is being finalized, we can review some technologies and design methodologies that are advantageous, despite their relative uncommonness in astronomical instrumentation. Particular for the Mercator Telescope is that it is controlled by a single high-end soft-PLC (Programmable Logic Controller). Using off-the-shelf components only, our distributed embedded system controls all subsystems of the telescope such as the pneumatic primary mirror support, the hydrostatic bearing, the telescope axes, the dome, the safety system, and so on. We show how real-time application logic can be written conveniently in typical PLC languages (IEC 61131-3) and in C++ (to implement the pointing kernel) using the commercial TwinCAT 3 programming environment. This software processes the inputs and outputs of the distributed system in real-time via an observatory-wide EtherCAT network, which is synchronized with high precision to an IEEE 1588 (PTP, Precision Time Protocol) time reference clock. Taking full advantage of the ability of soft-PLCs to run both real-time and non real-time software, the same device also hosts the most important user interfaces (HMIs or Human Machine Interfaces) and communication servers (OPC UA for process data, FTP for XML configuration data, and VNC for remote control). To manage the complexity of the system and to streamline the development process, we show how most of the software, electronics and systems engineering aspects of the control system have been modeled as a set of scripts written in a Domain Specific Language (DSL). When executed, these scripts populate a Knowledge Base (KB) which can be queried to retrieve specific information. By feeding the results of those queries to a template system, we were able to generate very detailed "browsable" web-based documentation about the system, but also PLC software code, Python client code, model verification reports, etc. The aim of this paper is to

  9. Line-plane broadcasting in a data communications network of a parallel computer

    Archer, Charles J.; Berg, Jeremy E.; Blocksome, Michael A.; Smith, Brian E.

    2010-06-08

    Methods, apparatus, and products are disclosed for line-plane broadcasting in a data communications network of a parallel computer, the parallel computer comprising a plurality of compute nodes connected together through the network, the network optimized for point to point data communications and characterized by at least a first dimension, a second dimension, and a third dimension, that include: initiating, by a broadcasting compute node, a broadcast operation, including sending a message to all of the compute nodes along an axis of the first dimension for the network; sending, by each compute node along the axis of the first dimension, the message to all of the compute nodes along an axis of the second dimension for the network; and sending, by each compute node along the axis of the second dimension, the message to all of the compute nodes along an axis of the third dimension for the network.

  10. Development of tools for automatic generation of PLC code

    Koutli, Maria; Rochez, Jacques

    This Master thesis was performed at CERN and more specifically in the EN-ICE-PLC section. The Thesis describes the integration of two PLC platforms, that are based on CODESYS development tool, to the CERN defined industrial framework, UNICOS. CODESYS is a development tool for PLC programming, based on IEC 61131-3 standard, and is adopted by many PLC manufacturers. The two PLC development environments are, the SoMachine from Schneider and the TwinCAT from Beckhoff. The two CODESYS compatible PLCs, should be controlled by the SCADA system of Siemens, WinCC OA. The framework includes a library of Function Blocks (objects) for the PLC programs and a software for automatic generation of the PLC code based on this library, called UAB. The integration aimed to give a solution that is shared by both PLC platforms and was based on the PLCOpen XML scheme. The developed tools were demonstrated by creating a control application for both PLC environments and testing of the behavior of the code of the library.

  11. A PLC platform-independent structural analysis on FBD programs for digital reactor protection systems

    Jung, Sejin; Yoo, Junbeom; Lee, Young-Jun

    2017-01-01

    Highlights: • FBD has been widely used to implement safety-critical software for PLC-based systems. • The safety-critical software should be developed strictly with safety programming guidelines. • There are no argued rules that have specific links to higher guidelines NUREG/CR-6463 PLC platform-independently. • This paper proposes a set of rules on the structure of FBD programs with providing specific links to higher guidelines. • This paper also provides CASE tool ‘FBD Checker’ for analyzing the structure of FBD. - Abstract: FBD (function block diagram) has been widely used to implement safety-critical software for PLC (programmable logic controller)-based digital nuclear reactor protection systems. The software should be developed strictly in accordance with safety programming guidelines such as NUREG/CR-6463. Software engineering tools of PLC vendors enable us to present structural analyses using FBD programs, but specific rules pertaining to the guidelines are enclosed within the commercial tools, and specific links to the guidelines are not clearly communicated. This paper proposes a set of rules on the structure of FBD programs in accordance with guidelines, and we develop an automatic analysis tool for FBD programs written in the PLCopen TC6 format. With the proposed tool, any FBD program that is transformed into an open format can be analyzed the PLC platform-independently. We consider a case study on FBD programs obtained from a preliminary version of a Korean nuclear power plant, and we demonstrate the effectiveness and potential of the proposed rules and analysis tool.

  12. Influence of non-line of sight luminescent emitters in visible light communication systems

    Ghorai, Anaranya; Walvekar, Pratik; Nayak, Shreyas; Narayan, K. S.

    2018-01-01

    We introduce and demonstrate concepts which utilize the non-line of sight fraction of light incident on a detector assembly in a visible-light communication (VLC) system. In addition to ambient light, realistic enclosures where VLC is implemented consist of a sizable fraction of scattered and reflected light. We present results of VLC systems with detectors responding to contributions from the light source scattered off a surface embedded with fluorescent and phosphorescent emitters besides the direct line of sight signal. Contribution from the emitters takes a form of discernible fluctuations in the detector signal. The implication of our results from noise analysis of these fluctuations indicates the possibility of utilizing smart coatings to further tailor VLC capabilities.

  13. Csseverin inhibits apoptosis through mitochondria-mediated pathways triggered by Ca2 + dyshomeostasis in hepatocarcinoma PLC cells.

    Mengchen Shi

    2017-11-01

    Full Text Available Numerous experimental and epidemiological studies have demonstrated a link between Clonorchis sinensis (C. sinensis infestation and cholangiocarcinoma (CCA as well as hepatocellular carcinoma (HCC. The underlying molecular mechanism involved in the malignancy of CCA and HCC has not yet been addressed. Csseverin, a component of the excretory/secretory products of C. sinensis (CsESPs, was confirmed to cause obvious apoptotic inhibition in the human HCC cell line PLC. However, the antiapoptotic mechanism is unclear. In the present study, we investigated the cellular features of the antiapoptotic mechanism upon transfection of the Csseverin gene.In the present study, we evaluated the effects of Csseverin gene overexpression on the apoptosis of PLC cells using an Annexin PE/7-AAD assay. Western blotting was applied to quantify the activation of caspase-3 and caspase-9, the mitochondrial translocation of Bax and the release of Cyt c upon Csseverin overexpression in PLC cells. Laser scanning confocal microscopy was used to analyze the changes of intracellular calcium. Fluorescence assay and immunofluorescence assays were performed to observe the changes of the mitochondrial permeability transition pore (MPTP.The overexpression of Csseverin in PLC cells showed apoptosis resistance after the induction of apoptosis. Additionally, the activation of caspase-3 and caspase-9 was specifically weakened in Csseverin overexpression PLC cells. The overexpression of Csseverin reduced the increase in intracellular free Ca2+, thereby inhibiting MPTP opening in PLC cells. Moreover, Bax mitochondrial translocation and the subsequent release of Cyt c were downregulated in apoptotic Csseverin overexpression PLC cells.The present findings suggest that Csseverin, a component of CsESPs, confers protection from human HCC cell apoptosis via the inactivation of membranous Ca2+ channels. Csseverin might be involved in the process of HCC through C. sinensis infestation in

  14. Non-line-of-sight ultraviolet communication based on DHT ACO-OFDM

    Gao, Qian; Chen, Gang

    2012-10-01

    Free space optical (FSO) communication has attracted tremendous research interest in the recent year. Most existing works focus only on the line-of-sight (LOS) transmission by infrared (IR) or visible light lasers/LEDs, while this article suggested a framework of non-line-of-sight (NLOS) FSO, motivated by our recent experimental results on the successful transmission of NLOS ultraviolet (UV) beams for up to kilometers, which is comparable to the typical distance a LOS FSO transmission. The NLOS provides an alternate path when the LOS path is shadowed or is highly attenuated. In order to mitigate the multipath dispersion of the NLOS FSO, a baseband orthogonal frequency division multiplexing (OFDM) modulation scheme was proposed, based on Discrete Hartley Transform (DHT) and asymmetric clipping to guarantee the positive-realness of the transmitted optical intensity. The proposed system could reduce the hardware complexity of transmitter and receiver. Minimum mean square error (MMSE) precoder was applied before the DHT to remove the crosstalk between subcarriers, i.e. the frequency domain orthogonality of OFDM was preserved. Performance of the BPSK modulated communication system was given under lognormal atmospheric turbulence for demonstration of the feasibility of the proposed method.

  15. Model to Counter the Threats in the Data Transmission System PLC-based Technology with the Use of Petri Nets

    A. A. Balaev

    2010-06-01

    Full Text Available In the article the most important aspects of information security technology Power Line Communica tions, namely the provision of conditions accessibility and integrity, are considered. It is shown that these aspects of the PLC-Technology has some internal “potential” counter, at least, such a widespread threat to both natural disturbances and/or artificial origin. The possibility of such an implementation using the simplified mathematical model of the PLC-based technologies of the theory of Petri nets is presented.

  16. On an LAS-integrated soft PLC system based on WorldFIP fieldbus.

    Liang, Geng; Li, Zhijun; Li, Wen; Bai, Yan

    2012-01-01

    Communication efficiency is lowered and real-time performance is not good enough in discrete control based on traditional WorldFIP field intelligent nodes in case that the scale of control in field is large. A soft PLC system based on WorldFIP fieldbus was designed and implemented. Link Activity Scheduler (LAS) was integrated into the system and field intelligent I/O modules acted as networked basic nodes. Discrete control logic was implemented with the LAS-integrated soft PLC system. The proposed system was composed of configuration and supervisory sub-systems and running sub-systems. The configuration and supervisory sub-system was implemented with a personal computer or an industrial personal computer; running subsystems were designed and implemented based on embedded hardware and software systems. Communication and schedule in the running subsystem was implemented with an embedded sub-module; discrete control and system self-diagnosis were implemented with another embedded sub-module. Structure of the proposed system was presented. Methodology for the design of the sub-systems was expounded. Experiments were carried out to evaluate the performance of the proposed system both in discrete and process control by investigating the effect of network data transmission delay induced by the soft PLC in WorldFIP network and CPU workload on resulting control performances. The experimental observations indicated that the proposed system is practically applicable. Copyright © 2011 ISA. Published by Elsevier Ltd. All rights reserved.

  17. Demand management through centralized control system using power line communication for existing buildings

    Al-Mulla, A.; ElSherbini, A.

    2014-01-01

    Highlights: • A pilot system was developed for demand management of equipment in buildings. • The networking was based on LonWorks platform and power line communication. • Demand strategies led to load reductions up to 74% and energy savings up to 25%. • The peak load reduction is expected to reach 3.44 GW by the year 2030. - Abstract: Managing peak demand efficiently is vital for maintaining uninterrupted supply of electrical power by utility providers. In this work, a pilot system was developed for managing and controlling the demand of major power consuming equipment in buildings from a central server, while relying mostly on existing infrastructure and maintaining consumer comfort. The system was successfully demonstrated on a selected group of buildings using the LonWorks networking platform. At the building level, the system utilized power line and twisted pair communication to control the thermostats of air-conditioning (A/C) units. The higher level communication was executed through extensible markup language (XML) and simple object access protocol (SOAP). The system provided control capabilities based on A/C unit priority, thermostat temperature, building type and geographic location. The development and execution of demand management strategies for selected buildings led to peak load reductions up to 74%, in addition to energy savings up to 25%. Implementing such a system at a national level in Kuwait is estimated to reduce peak demand by 3.44 GW, amounting to capital savings of $4.13 billion. The use of existing infrastructure reduced the cost and installation time of the system. Based on the successful testing of this pilot system, a larger-scale system is being developed

  18. Generic requirements specification for qualifying a commercially available PLC for safety-related applications in nuclear power plants. Final report

    Ostenso, A.; May, R.

    1996-12-01

    This is a specification for qualifying a commercially available PLC for application to safety systems in nuclear power plants. The specifications are suitable for evaluating a particular PLC product line as a platform for safety-related applications, establishing a suitable qualification test program, and confirming that the manufacturer has a quality assurance program that is adequate for safety-related applications or is sufficiently complete that, with a reasonable set of compensatory actions, it can be brought into conformance. The specification includes requirements for: (1) quality assurance measures applied to the qualification activities, (2) documentation to support the qualification, and (3) documentation to provide the information needed for applying the qualified PLC platform to a specific application. The specifications are designed to encompass a broad range of safety applications; however, qualifying a particular platform for a different range of applications can be accomplished by appropriate adjustments to the requirements

  19. Heating systems with PLC and frequency control

    Abdallah, Salah; Abu-Mallouh, Riyad

    2008-01-01

    In this work, medium capacity controlled heating system is designed and constructed. The programming method of control of heating process is achieved by means of integrated programmable logic controller (PLC) and frequency inverter (FI). The PLC main function is to determine the required temperatures levels and the related time intervals of the heating hold time in the furnace. FI is used to control the dynamic change of temperature between various operating points. The designed system shows the capability for full control of temperature from zero to maximum for any required range of time in case of increasing or decreasing the temperature. All variables of the system will be changed gradually until reaching their needed working points. An experimental study was performed to investigate the effect of tempering temperature and tempering time on hardness and fatigue resistance of 0.4% carbon steel. It was found that increasing tempering temperature above 550 deg. C or tempering time decreases the hardness of the material. It was also found that there is a maximum number of cycles to which the specimen can survive what ever the applied load was

  20. Reliability Analysis for Safety Grade PLC(POSAFE-Q)

    Choi, Kyung Chul; Song, Seung Whan; Park, Gang Min; Hwang, Sung Jae

    2012-01-01

    Safety Grade PLC(Programmable Logic Controller), POSAFE-Q, was developed recently in accordance with nuclear regulatory and requirements. In this paper, describe reliability analysis for digital safety grade PLC (especially POSAFE-Q). Reliability analysis scope is Prediction, Calculation of MTBF (Mean Time Between Failure), FMEA (Failure Mode Effect Analysis), PFD (Probability of Failure on Demand). (author)

  1. Application of Kingview and PLC in friction durability test system

    Gao, Yinhan; Cui, Jing; Yang, Kaiyu; Ke, Hui; Song, Bing

    2013-01-01

    Using PLC and Kingview software, a friction durability test system is designed. The overall program, hardware configuration, software structure and monitoring interface are described in detail. PLC ensures the stability of data acquisition, and the KingView software makes the HMI easy to manipulate. The practical application shows that the proposed system is cheap, economical and highly reliable.

  2. Application of PLC in the crane control system of MJTR

    Li Ziqiang; Ji Xiangdong

    2004-01-01

    The paper describes the application of PLC (Programmable Controller) in the control system of the bridge crane. PLC is the essential part of the control system, which uses some equipment such as frequency transformer and photoelectric switch to implement remote, manual and automatic centering functions. This paper emphasizes the programming of the automatic hole centering

  3. Full-automatic Special Drill Hydraulic System and PLC Control

    Tian Xue Jun

    2016-01-01

    Full Text Available A hydraulic-driven and PLC full-automatic special drill is introduced, working principle of the hydraulic system and PLC control system are analyzed and designed, this equipment has the advantages of high efficiency, superior quality and low cost etc.

  4. Automatic production of Iodine-123 with PLC 135/U

    Moghaddam-Banaem, L.; Afarideh, H.

    2004-01-01

    In this project, the automatic system for production of Iodine-123 with PLC/135μ Siemens, which is designed and installed for the first time in Iran, is discussed. The PLC (Programmable Logic Controller) is used to control industrial processing, which is similar to a computer and consists of central processing unit and memory and Input/Output units. PLC receives input information from auxiliary units such as sensors, switches, etc. and software processes data in memory and then sends commands to output units such as relays, motors, etc.The target section in Iodine production consists of 8 stages. In order to be sure automation works properly the system can be operated both manually and automatically. First PLC checks Manual/Automatic switch and in the case of automatic mode, PLC runs the program in memory and processing is done automatically. For this purpose, PLC takes the value of pressures and temperatures from analog inputs and after processing them it sends commands to digital output to activate valves or vacuum pumps or heaters. In this paper the following subjects are discussed: 1) Production of Iodine 123 2) PLC structure and auxiliary boards 3) Sensors and actuators and their connection to PLC 4) Software flowchart

  5. Design of monitoring system for mail-sorting based on the Profibus S7 series PLC

    Zhang, W.; Jia, S. H.; Wang, Y. H.; Liu, H.; Tang, G. C.

    2017-01-01

    With the rapid development of the postal express, the workload of mail sorting is increasing, but the automatic technology of mail sorting is not mature enough. In view of this, the system uses Siemens S7-300 PLC as the main station controller, PLC of Siemens S7-200/400 is from the station controller, through the man-machine interface configuration software MCGS, PROFIBUS-DP communication, RFID technology and mechanical sorting hand achieve mail classification sorting monitoring. Among them, distinguish mail-sorting by scanning RFID posted in the mail electronic bar code (fixed code), the system uses the corresponding controller on the acquisition of information processing, the processed information transmit to the sorting manipulator by PROFIBUS-DP. The system can realize accurate and efficient mail sorting, which will promote the development of mail sorting technology.

  6. Communication: Diffusion constant in supercooled water as the Widom line is crossed in no man's land

    Ni, Yicun; Hestand, Nicholas J.; Skinner, J. L.

    2018-05-01

    According to the liquid-liquid critical point (LLCP) hypothesis, there are two distinct phases of supercooled liquid water, namely, high-density liquid and low-density liquid, separated by a coexistence line that terminates in an LLCP. If the LLCP is real, it is located within No Man's Land (NML), the region of the metastable phase diagram that is difficult to access using conventional experimental techniques due to rapid homogeneous nucleation to the crystal. However, a recent ingenious experiment has enabled measurement of the diffusion constant deep inside NML. In the current communication, these recent measurements are compared, with good agreement, to the diffusion constant of E3B3 water, a classical water model that explicitly includes three-body interactions. The behavior of the diffusion constant as the system crosses the Widom line (the extension of the liquid-liquid coexistence line into the one-phase region) is analyzed to derive information about the presence and location of the LLCP. Calculations over a wide range of temperatures and pressures show that the new experimental measurements are consistent with an LLCP having a critical pressure of over 0.6 kbar.

  7. Women On-Line: Cultural and Relational Aspects of Women's Communication in On-line Discussion Groups.

    Ferris, Sharmila Pixy

    1996-01-01

    Women's online communication often mirrors that of face-to-face communication, linguistically and relationally. Women-only online communities, however, provide an opportunity to develop a distinct relational and cultural style. Discusses gender differences in face-to-face language use, and in mixed gender online discussion groups. Describes…

  8. Reliability assessment of fiber optic communication lines depending on external factors and diagnostic errors

    Bogachkov, I. V.; Lutchenko, S. S.

    2018-05-01

    The article deals with the method for the assessment of the fiber optic communication lines (FOCL) reliability taking into account the effect of the optical fiber tension, the temperature influence and the built-in diagnostic equipment errors of the first kind. The reliability is assessed in terms of the availability factor using the theory of Markov chains and probabilistic mathematical modeling. To obtain a mathematical model, the following steps are performed: the FOCL state is defined and validated; the state graph and system transitions are described; the system transition of states that occur at a certain point is specified; the real and the observed time of system presence in the considered states are identified. According to the permissible value of the availability factor, it is possible to determine the limiting frequency of FOCL maintenance.

  9. Alternative Line Coding Scheme with Fixed Dimming for Visible Light Communication

    Niaz, M. T.; Imdad, F.; Kim, H. S.

    2017-01-01

    An alternative line coding scheme called fixed-dimming on/off keying (FD-OOK) is proposed for visible-light communication (VLC). FD-OOK reduces the flickering caused by a VLC transmitter and can maintain a 50% dimming level. Simple encoder and decoder are proposed which generates codes where the number of bits representing one is same as the number of bits representing zero. By keeping the number of ones and zeros equal the change in the brightness of lighting may be minimized and kept constant at 50%, thereby reducing the flickering in VLC. The performance of FD-OOK is analysed with two parameters: the spectral efficiency and power requirement.

  10. Cellular Genetic Algorithm with Communicating Grids for Assembly Line Balancing Problems

    BRUDARU, O.

    2010-05-01

    Full Text Available This paper presents a new approach with cellular multigrid genetic algorithms for the "I"-shaped and "U"-shaped assembly line balancing problems, including parallel workstations and compatibility constraints. First, a cellular hybrid genetic algorithm that uses a single grid is described. Appropriate operators for mutation, hypermutation, and crossover and two devoration techniques are proposed for creating and maintaining groups based on similarity. This monogrid algorithm is extended for handling many populations placed on different grids. In the multigrid version, the population of each grid is organized in clusters using the positional information of the chromosomes. A similarity preserving communication protocol between the clusters placed on different grids is introduced. The experimental evaluation shows that the multigrid cellular genetic algorithm with communicating grids is better than the hybrid genetic algorithm used for building it, whereas it dominates the monogrid version in all cases. Absolute performance is evaluated using classical benchmarks. The role of certain components of the cellular algorithm is explained and the effect of some parameters is evaluated.

  11. Extending the range and performance of non-line-of-sight ultraviolet communication links

    Shaw, Gary A.; Siegel, Andrew M.; Model, Joshua

    2006-05-01

    This paper describes recent advances in the technology for, and implementation of, short-range non-line-of-sight (NLOS) optical communication links. The approach relies on molecular scattering of ultraviolet wavelengths by the atmosphere to achieve NLOS, omni-directional communication Links. The implementation employs commercially produced semiconductor sources emitting in the solar-blind region of the UV spectrum, around 275nm. This paper extends previously reported field measurements to longer ranges (100+m) and to a wider variety of application scenarios, including an outdoor demonstration of real-time speech at 2.4kbps in full sunlight. The paper also addresses the design trades associated with replacing photomultiplier detectors with semiconductor detectors for reasons of cost and ruggedness. Even with improvements in semiconductor materials and commensurate reduction in dark currents, the use of semiconductor detectors will require the introduction of imaging arrays. Incorporation of imaging arrays opens the possibility of adaptive links in which bandwidth and transmit power are adapted to best exploit the channel constraints.

  12. Wideband Impulse Modulation and Receiver Algorithms for Multiuser Power Line Communications

    Andrea M. Tonello

    2007-01-01

    Full Text Available We consider a bit-interleaved coded wideband impulse-modulated system for power line communications. Impulse modulation is combined with direct-sequence code-division multiple access (DS-CDMA to obtain a form of orthogonal modulation and to multiplex the users. We focus on the receiver signal processing algorithms and derive a maximum likelihood frequency-domain detector that takes into account the presence of impulse noise as well as the intercode interference (ICI and the multiple-access interference (MAI that are generated by the frequency-selective power line channel. To reduce complexity, we propose several simplified frequency-domain receiver algorithms with different complexity and performance. We address the problem of the practical estimation of the channel frequency response as well as the estimation of the correlation of the ICI-MAI-plus-noise that is needed in the detection metric. To improve the estimators performance, a simple hard feedback from the channel decoder is also used. Simulation results show that the scheme provides robust performance as a result of spreading the symbol energy both in frequency (through the wideband pulse and in time (through the spreading code and the bit-interleaved convolutional code.

  13. WINDING METHOD SELECTION FOR TECHNICAL IMPLEMENTATION OF FIBER OPTIC COMMUNICATION LINE FOR HIGH-SPEED OBJECT

    Vyacheslav A. Loparev

    2017-07-01

    Full Text Available The paper deals with fiber-optical cable winding methods for realization of fiber-optic communication line with high-speed object. We consider possible options of coils for optical cable winding providing mobility of one of the cable ends on an object. It is shown that the choice of a winding process is caused by the need of ensuring the minimum deformation of fiber-optical micro cable in case of separation from a winding body. It is revealed that the minimum tension value and its unevenness are observed when reeling from coils with a rocket form. Design ratios for determination of winding parameters are given. It is shown that reduction of tension unevenness reduces the jumps of internal tension and probability of break and emergence of optical signal local attenuation. Decrease in internal stresses occurs due to the absence of overlapping of the coils of the underlying layers with the overlying ones. To confirm the operability and the possibility of constructive implementation of the selected winding scheme, experiments were carried out to perform rocket and other types of winding with the use of a specially designed machine model. It is shown that the application of line rocket winding enables to achieve stability when reeling a cable during the movement and excludes breaks. Attenuation of optical signal decreases due to the increase in the bend minimum radius. This phenomenon is explained by reduction of the internal stresses causing optical signal attenuation in the place of cable separation from the coil.

  14. Modeling a Consistent Behavior of PLC-Sensors

    E. V. Kuzmin

    2014-01-01

    Full Text Available The article extends the cycle of papers dedicated to programming and verificatoin of PLC-programs by LTL-specification. This approach provides the availability of correctness analysis of PLC-programs by the model checking method.The model checking method needs to construct a finite model of a PLC program. For successful verification of required properties it is important to take into consideration that not all combinations of input signals from the sensors can occur while PLC works with a control object. This fact requires more advertence to the construction of the PLC-program model.In this paper we propose to describe a consistent behavior of sensors by three groups of LTL-formulas. They will affect the program model, approximating it to the actual behavior of the PLC program. The idea of LTL-requirements is shown by an example.A PLC program is a description of reactions on input signals from sensors, switches and buttons. In constructing a PLC-program model, the approach to modeling a consistent behavior of PLC sensors allows to focus on modeling precisely these reactions without an extension of the program model by additional structures for realization of a realistic behavior of sensors. The consistent behavior of sensors is taken into account only at the stage of checking a conformity of the programming model to required properties, i. e. a property satisfaction proof for the constructed model occurs with the condition that the model contains only such executions of the program that comply with the consistent behavior of sensors.

  15. Trends in Control Area of PLC Reliability and Safety Parameters

    Juraj Zdansky

    2008-01-01

    Full Text Available Extension of the PLC application possibilities is closely related to increase of reliability and safety parameters. If the requirement of reliability and safety parameters will be suitable, the PLC could by implemented to specific applications such the safety-related processes control. The goal of this article is to show the way which producers are approaching to increase PLC`s reliability and safety parameters. The second goal is to analyze these parameters for range of present choice and describe the possibility how the reliability and safety parameters can be affected.

  16. Analysis of the PLC object model in the PF linac

    Abe, Isamu; Shirakawa, Akihiro; Nakahara, Kazuo; Tanaka, Masahiko

    1995-01-01

    Device controllers (front end) for the KEK PF Linac, which has been operated for more than ten years, had to be renewed, because there is no longer support from hardware manufacturer. To reduce maintenance costs, device controllers are planed to be replaced by PLC (Programmable Logic Controller). Investigations launched in the late 1994s for the PLC have carried out in order to make sure of the I/O stability and network possibilities. In this paper, the software for the PLC is discussed based on the OOP concept. (author)

  17. Virtual Modular Redundancy of Processor Module in the PLC

    Lee, Kwang-Il; Hwang, SungJae; Yoon, DongHwa

    2016-01-01

    Dual Modular Redundancy (DMR) is mainly used to implement these safety control systems. DMR is conveyed when components of a system are duplicated, providing another component in case one should fault or fail. This feature has a high availability and large fault tolerant. It provides zero downtime that is required for nuclear power plants. So nuclear power plant has been commercialized by multiple redundant systems. The following paper, we propose a Virtual Modular Redundancy (VMR) rather than physical triple of the Programmable Logic Controller (PLC) processor module to ensure the reliability of the nuclear power plant control system. VMR implementation minimizes design changes to continue to use the commercially available redundant system. Also, the purpose of the VMR is to improve the efficiency and reliability in many ways, such as fault tolerant and fail-safe and cost. VMR guarantees a wide range of reliable fault recovery, fault tolerance, etc. It is prevented before it causes great damages due to the continuous failure of the two modules. The reliable communication speed is slow and also it has a small bandwidth. It is a great loss in the safety control system. However, VMR aims to avoid nuclear power plants that were suspended due to fail-safe. It is not for the purpose of commonly used. Application of VMR is actually expected to require a lot of research and trial and error until they adapt to the nuclear regulatory and standards

  18. Virtual Modular Redundancy of Processor Module in the PLC

    Lee, Kwang-Il; Hwang, SungJae; Yoon, DongHwa [SOOSAN ENS Co., Seoul (Korea, Republic of)

    2016-10-15

    Dual Modular Redundancy (DMR) is mainly used to implement these safety control systems. DMR is conveyed when components of a system are duplicated, providing another component in case one should fault or fail. This feature has a high availability and large fault tolerant. It provides zero downtime that is required for nuclear power plants. So nuclear power plant has been commercialized by multiple redundant systems. The following paper, we propose a Virtual Modular Redundancy (VMR) rather than physical triple of the Programmable Logic Controller (PLC) processor module to ensure the reliability of the nuclear power plant control system. VMR implementation minimizes design changes to continue to use the commercially available redundant system. Also, the purpose of the VMR is to improve the efficiency and reliability in many ways, such as fault tolerant and fail-safe and cost. VMR guarantees a wide range of reliable fault recovery, fault tolerance, etc. It is prevented before it causes great damages due to the continuous failure of the two modules. The reliable communication speed is slow and also it has a small bandwidth. It is a great loss in the safety control system. However, VMR aims to avoid nuclear power plants that were suspended due to fail-safe. It is not for the purpose of commonly used. Application of VMR is actually expected to require a lot of research and trial and error until they adapt to the nuclear regulatory and standards.

  19. Developing a PLC-friendly state machine model: lessons learned

    Pessemier, Wim; Deconinck, Geert; Raskin, Gert; Saey, Philippe; Van Winckel, Hans

    2014-07-01

    Modern Programmable Logic Controllers (PLCs) have become an attractive platform for controlling real-time aspects of astronomical telescopes and instruments due to their increased versatility, performance and standardization. Likewise, vendor-neutral middleware technologies such as OPC Unified Architecture (OPC UA) have recently demonstrated that they can greatly facilitate the integration of these industrial platforms into the overall control system. Many practical questions arise, however, when building multi-tiered control systems that consist of PLCs for low level control, and conventional software and platforms for higher level control. How should the PLC software be structured, so that it can rely on well-known programming paradigms on the one hand, and be mapped to a well-organized OPC UA interface on the other hand? Which programming languages of the IEC 61131-3 standard closely match the problem domains of the abstraction levels within this structure? How can the recent additions to the standard (such as the support for namespaces and object-oriented extensions) facilitate a model based development approach? To what degree can our applications already take advantage of the more advanced parts of the OPC UA standard, such as the high expressiveness of the semantic modeling language that it defines, or the support for events, aggregation of data, automatic discovery, ... ? What are the timing and concurrency problems to be expected for the higher level tiers of the control system due to the cyclic execution of control and communication tasks by the PLCs? We try to answer these questions by demonstrating a semantic state machine model that can readily be implemented using IEC 61131 and OPC UA. One that does not aim to capture all possible states of a system, but rather one that attempts to organize the course-grained structure and behaviour of a system. In this paper we focus on the intricacies of this seemingly simple task, and on the lessons that we

  20. New Concept of PLC Modems: Multi-Carrier System for Frequency Selective Slow-Fading Channels Based on Layered SCCC Turbocodes

    J. Zavrtalek

    2015-09-01

    Full Text Available The article introduces a novel concept of a PLC modem as a complement to the existing G3 and PRIME standards for communications using medium- or high-voltage overhead or cable lines. The proposed concept is based on the fact that the levels of impulse noise and frequency selectivity are lower on high-voltage lines than on low-voltage ones. Also, the demands for “cost-effective” circuitry design are not so crucial as in the case of modems for low-voltage level. In contract to these positive conditions, however, there is the need to overcome much longer distances and to take into account low SNR on the receiving side. With respect to the listed reasons, our concept makes use of MCM, instead of OFDM. The assumption of low SNR is compensated through the use of an efficient channel coding based on a serially concatenated turbo code. In addition, MCM offers lower latency and PAPR compared to OFDM. Therefore, when using MCM, it is possible to excite the line with higher power. The proposed concept has been verified during experimental transmission of testing data over a real, 5 km long, 22kV overhead line.

  1. Applying Model Checking to Industrial-Sized PLC Programs

    AUTHOR|(CDS)2079190; Darvas, Daniel; Blanco Vinuela, Enrique; Tournier, Jean-Charles; Bliudze, Simon; Blech, Jan Olaf; Gonzalez Suarez, Victor M

    2015-01-01

    Programmable logic controllers (PLCs) are embedded computers widely used in industrial control systems. Ensuring that a PLC software complies with its specification is a challenging task. Formal verification has become a recommended practice to ensure the correctness of safety-critical software but is still underused in industry due to the complexity of building and managing formal models of real applications. In this paper, we propose a general methodology to perform automated model checking of complex properties expressed in temporal logics (\\eg CTL, LTL) on PLC programs. This methodology is based on an intermediate model (IM), meant to transform PLC programs written in various standard languages (ST, SFC, etc.) to different modeling languages of verification tools. We present the syntax and semantics of the IM and the transformation rules of the ST and SFC languages to the nuXmv model checker passing through the intermediate model. Finally, two real cases studies of \\CERN PLC programs, written mainly in th...

  2. Programmable logic controller (PLC) for safety systems of nuclear plants

    Sen, S.K.; Karmakar, G.; Joseph, Jose; Patil, R.K.

    2002-01-01

    Full text: A programmable logic controller (PLC) has been developed by RCnD, BARC for use in the safety critical systems in nuclear power plants. This PLC uses qualified hardware developed in RCnD for use in NPP. The programming software conforms to IEC-61131 part 3. The application programming is done on function block diagram (FBD) editor and the FBD is automatically converted into code in high level language (C / C++). This feature makes the application easily decipherable and therefore easily subjected to reviews and other validation techniques. The key to make quality software for use in nuclear systems is to enforce various standards in the design and development of the software, something, which is not possible to do with a commercially available PLC. This PLC with its software completely transparent lends itself to rigorous verification and validation easily

  3. Voltage Control System of A DC Generator Using PLC

    Subrata CHATTOPADHYAY; Sagarika PAL

    2008-01-01

    The voltage control system of a DC generator may suffer from high frequency oscillations without offset or low frequency oscillation with offset. A PID controller can eliminate both these errors. In the present paper, the voltage control system of a DC generator using a PLC based PID controller has been designed. Operation of PLC as a continuous controller has been described and the load characteristic of DC generator with and without controller have been determined experimentally and reporte...

  4. To Solution of Classical Problem Pertaining to Magnetic Interference of Overhead Power Transmission Line on Extended Conducting Communications

    V. I. Glushko

    2013-01-01

    Full Text Available The paper considers a problem pertaining to magnetic interference of overhead power transmission lines and high-voltage bus bars of electrical installations on extended conducting communications and secondary circuits of relay protection and automation. A simplified task solution has been obtained on the basis of the Carson integral approximation.

  5. Below the poverty line and non-communicable diseases in Kerala: The Epidemiology of Non-communicable Diseases in Rural Areas (ENDIRA) study.

    Menon, Jaideep; Vijayakumar, N; Joseph, Joseph K; David, P C; Menon, M N; Mukundan, Shyam; Dorphy, P D; Banerjee, Amitava

    2015-01-01

    India carries the greatest burden of global non-communicable diseases (NCDs). Poverty is strongly associated with NCDs but there are few prevalence studies which have measured poverty in India, particularly in rural settings. In Kerala, India, a population of 113,462 individuals was identified. The "Epidemiology of Non-communicable Diseases in Rural Areas" (ENDIRA) study was conducted via ASHAs (Accredited Social Health Activists). Standardised questionnaires were used in household interviews of individuals ≥18years during 2012 to gather sociodemographic, lifestyle and medical data for this population. The Government of Kerala definition of "the poverty line" was used. The association between below poverty line (BPL) status, NCDs and risk factors was analysed in multivariable regression models. 84,456 adults were included in the analyses (25.4% below the poverty line). The prevalence of NCDs was relatively common: myocardial infarction (MI) 1.4%, stroke 0.3%, respiratory diseases 5.0%, and cancer 1.1%. BPL status was not associated with age (p=0.96) or gender (p=0.26). Compared with those above the poverty line (APL), the BPL group was less likely to have diabetes, hypertension or dyslipidaemia (ppoverty line status. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. Safety culture development in nuclear electric plc

    Gibson, G.P.; Low, M.B.J.

    1995-01-01

    Nuclear Electric plc (NE) has always given the highest priority to safety. However, past emphasis has been directed towards ensuring safety thorough engineering design and hazard control procedures. Whilst the company did achieve high safety standards, particularly with respect to accidents, it was recognized that further improvements could be obtained. Analysis of the safety performance across a wide range of industries showed that the key to improving safety performance lay in developing a strong safety culture within the company. Over the last five years, NE has made great strides to improve its safety culture. This has resulted in a considerable improvement in its measured safety performance indicators, such as the number of incidents at international nuclear event scale (INES) rating 1, the number of lost time accidents and the collective radiation dose. However, despite this success, the company is committed to further improvement and a means by which this process becomes self-sustaining. In this way the company will achieve its prime goal, to ''ensure the safety of people, plant and the environment''. The paper provides an overview of the development of safety culture in NE since its formation in November 1989. It describes the research and international developments that have influenced the company's understanding of safety culture, the key initiatives that the company has undertaken to enhance its safety culture and the future initiatives being considered to ensure continual improvement. (author). 5 refs, 2 figs, 2 tabs

  7. Electric Vehicle Communications Standards Testing and Validation - Phase II: SAE J2931/1

    Pratt, Richard M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Gowri, Krishnan [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2013-01-15

    Vehicle to grid communication standards enable interoperability among vehicles, charging stations and utility providers and provide the capability to implement charge management. Several standards initiatives by the Society of Automobile Engineers (SAE), International Standards Organization and International Electrotechnical Commission (ISO/IEC), and ZigBee/HomePlug Alliance are developing requirements for communication messages and protocols. Recent work by the Electric Power Research Institute (EPRI) in collaboration with SAE and automobile manufacturers has identified vehicle to grid communication performance requirements and developed a test plan as part of SAE J2931/1 committee work. This laboratory test plan was approved by the SAE J2931/1 committee and included test configurations, test methods, and performance requirements to verify reliability, robustness, repeatability, maximum communication distance, and authentication features of power line carrier (PLC) communication modules at the internet protocol layer level. The goal of the testing effort was to select a communication technology that would enable automobile manufacturers to begin the development and implementation process. The EPRI/Argonne National Laboratory (ANL)/Pacific Northwest National Laboratory (PNNL) testing teams divided the testing so that results for each test could be presented by two teams, performing the tests independently. The PNNL team performed narrowband PLC testing including the Texas Instruments (TI) Concerto, Ariane Controls AC-CPM1, and the MAXIM Tahoe 2 evaluation boards. The scope of testing was limited to measuring the vendor systems communication performance between Electric Vehicle Support Equipment (EVSE) and plug-in electric vehicles (PEV). The testing scope did not address PEV’s CAN bus to PLC or PLC to EVSE (Wi-Fi, cellular, PLC Mains, etc.) communication integration. In particular, no evaluation was performed to delineate the effort needed to translate the IPv6

  8. Cable line engineering

    Jang, Hak Sin; Kim, Sin Yeong

    1998-02-01

    This book is about cable line engineering. It is comprised of nine chapters, which deals with summary of cable communication such as way, process of cable communication and optical communication, Line constant of transmission on primary constant, reflection and crosstalk, communication cable line of types like flat cable, coaxial cable and loaded cable, Install of communication line with types and facility of aerial line, construction method of communication line facility, Measurement of communication line, Carrier communication of summary, PCM communication with Introduction, regeneration relay system sampling and quantization and Electric communication service and general information network with mobile communication technique and satellite communication system.

  9. Silencing of the tomato phosphatidylinositol-phospholipase C2 (SlPLC2) reduces plant susceptibility to Botrytis cinerea

    Gonorazky, Gabriela; Guzzo, María Carla; Abd-El-Haliem, Ahmed M.; Joosten, Matthieu H.A.J.; Laxalt, Ana María

    2016-01-01

    The tomato [Solanum lycopersicum (Sl)] phosphatidylinositol-phospholipase C (PI-PLC) gene family is composed of six members, named SlPLC1 to SlPLC6, differentially regulated on pathogen attack. We have previously shown that the fungal elicitor xylanase induces a raise of SlPLC2 and SlPLC5

  10. Data acquisition and control system with a programmable logic controller (PLC) for a pulsed chemical oxygen-iodine laser

    Yu, Haijun; Li, Guofu; Duo, Liping; Jin, Yuqi; Wang, Jian; Sang, Fengting; Kang, Yuanfu; Li, Liucheng; Wang, Yuanhu; Tang, Shukai; Yu, Hongliang

    2015-02-01

    A user-friendly data acquisition and control system (DACS) for a pulsed chemical oxygen -iodine laser (PCOIL) has been developed. It is implemented by an industrial control computer,a PLC, and a distributed input/output (I/O) module, as well as the valve and transmitter. The system is capable of handling 200 analogue/digital channels for performing various operations such as on-line acquisition, display, safety measures and control of various valves. These operations are controlled either by control switches configured on a PC while not running or by a pre-determined sequence or timings during the run. The system is capable of real-time acquisition and on-line estimation of important diagnostic parameters for optimization of a PCOIL. The DACS system has been programmed using software programmable logic controller (PLC). Using this DACS, more than 200 runs were given performed successfully.

  11. LINES

    Minas Bakalchev

    2015-10-01

    Full Text Available The perception of elements in a system often creates their interdependence, interconditionality, and suppression. The lines from a basic geometrical element have become the model of a reductive world based on isolation according to certain criteria such as function, structure, and social organization. Their traces are experienced in the contemporary world as fragments or ruins of a system of domination of an assumed hierarchical unity. How can one release oneself from such dependence or determinism? How can the lines become less “systematic” and forms more autonomous, and less reductive? How is a form released from modernistic determinism on the new controversial ground? How can these elements or forms of representation become forms of action in the present complex world? In this paper, the meaning of lines through the ideas of Le Corbusier, Leonidov, Picasso, and Hitchcock is presented. Spatial research was made through a series of examples arising from the projects of the architectural studio “Residential Transformations”, which was a backbone for mapping the possibilities ranging from playfulness to exactness, as tactics of transformation in the different contexts of the contemporary world.

  12. Users` demands narrow PLC-DCS gap

    La Fauci, J.

    1997-02-01

    Supervisory control and data acquisition (SCADA) operator interface (OI) software has propelled programmable logic controllers (PLCs) into areas where they can successfully compete with distributed control systems (DCSs) for many control applications. As a result, automation engineers are struggling to develop guidelines to help determine which is best for batch operations and other applications. There is no clear answer to this issue. There are, however, decision tools such as Kepner-Tregoe (K-T) that can be applied by engineers as a structured approach to decision analysis and system selection. Other factors such as business environment, pressure to reduce project cost, validation, and predicting new technology direction all play a critical role for engineers in choosing between a PLC- or DCS-based control system. Higher-level business issues, however, are seldom considered by engineers during control system selection. Engineers should try to better understand their company`s business objectives and mission statement and how company business direction may affect control system selection. For instance, the pharmaceutical industry can be broken up into the following five basic application groups: bulk chemicals, finishing, biotech, pilot plant, and utilities. Each has a unique set of functional and process-control requirements. Understanding needs and differences of these five basic application groups and applying the optimum control system solution will place the company in a more competitive position. A financial analysis should be one of the first steps in the control system evaluation process. This may include early agreement of contractual terms and conditions as well as a nondisclosure agreement. Other financial considerations may include requesting a financial report on the control system manufacturer or systems integrator that will be performing the work to determine its financial stability. 3 figs.

  13. A large number of stepping motor network construction by PLC

    Mei, Lin; Zhang, Kai; Hongqiang, Guo

    2017-11-01

    In the flexible automatic line, the equipment is complex, the control mode is flexible, how to realize the large number of step and servo motor information interaction, the orderly control become a difficult control. Based on the existing flexible production line, this paper makes a comparative study of its network strategy. After research, an Ethernet + PROFIBUSE communication configuration based on PROFINET IO and profibus was proposed, which can effectively improve the data interaction efficiency of the equipment and stable data interaction information.

  14. Study On Electromagnetic Compatibility of Powerline Communication Systems%电力线通信系统的电磁兼容性研究

    郭晓刚; 赵建峰; 李国庆

    2017-01-01

    电磁兼容性(Electromagnetic Compatibility,EMC)是电力线通信(Power Line Communication,PLC)系统的关键技术之一.首先介绍了PLC技术的发展概况和相应EMC研究的基本情况;并介绍了有代表性的国家或地区和重要的标准化组织在PLC技术的EMC法律法规和标准方面的最新进展;然后介绍了我国在该领域的试验结果和研究成果;最后指出该领域存在的问题、同时对发展方向提出建议.上述研究总结了PLC技术的EMC法规和标准化的最新进展,可作为我国发展PLC时制定合理的EMC法规和管理制度的有益参考.%EMC is one of the key technologies of PLC.Firstly,the development profile of PLC technology and its EMC study overview were introduced in the paper.Then the PLC EMC progresses on the regulations of representative countries or regions,as well as the standards of the important standardized organizations were described.After that,the testing results and the study achievements of some Chinese organizations were presented.Finally,the problems were pointed out,and some suggestions on development directions were proposed.The study is the summary of the latest status of PLC EMC regulations and standardization,which is a favorable reference for making the rules and administration of PLC EMC for China.

  15. Real time control “es-dawet” mixer using dasboard based on PLC and WSN

    Siagian, Pandapotan; Hutauruk, Sindak; Kisno

    2017-09-01

    The aim of this study is to monitor and acquire the remote parameters like Speed control a DC Motor, IR Sensor, Temperature of pasteurize mix of ice cream, and send these real values over wireless network. A proposed system is dashboard monitoring system for PLC based system wirelessly using ZigBee protocol. To implement this a ZigBee model is connected to a programmed digital signal controller which would transmit the data to Zigbee coordinator which is connected to a PC through RS232 serial communication. Person can need only to send the reply about the process that is to be carried out and PLC will check the status of the web base sent by person and take the action according to it where wired communication is either more expensive or impossible due to physical conditions. A low cost system for measured the parameters of motor such as IR Sensor, Speed control a DC Motor by PWM and temperature with Zigbee protocol connectivity. A database is built to execute monitoring and to save the motor parameters received by radio frequency (RF) data acquisition system. Experimental results show that the proposed system is less costly, provides higher accuracy as well as safe and gives visual environment.

  16. Prototype of Automated PLC Model Checking Using Continuous Integration Tools

    Lettrich, Michael

    2015-01-01

    To deal with the complexity of operating and supervising large scale industrial installations at CERN, often Programmable Logic Controllers (PLCs) are used. A failure in these control systems can cause a disaster in terms of economic loses, environmental damages or human losses. Therefore the requirements to software quality are very high. To provide PLC developers with a way to verify proper functionality against requirements, a Java tool named PLCverif has been developed which encapsulates and thus simplifies the use of third party model checkers. One of our goals in this project is to integrate PLCverif in development process of PLC programs. When the developer changes the program, all the requirements should be verified again, as a change on the code can produce collateral effects and violate one or more requirements. For that reason, PLCverif has been extended to work with Jenkins CI in order to trigger automatically the verication cases when the developer changes the PLC program. This prototype has been...

  17. La Nueva Generación de las Power Line Communications en el Servicio Triple Play

    Luís Enrique Conde del Oso

    2010-09-01

    Full Text Available Normal 0 21 false false false ES-TRAD X-NONE X-NONE MicrosoftInternetExplorer4 st1:*{behavior:url(#ieooui } /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Tabla normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;} Se explica las nuevas características presentes en la Nueva Generación de los sistemas Power Line Communication, así como las actuales posibilidades de los nuevos y novedosos servicios a ofertar con estos sistemas. Otros de los aspectos abordados en el artículo son la experiencia cubana en la implementación de varios diseños de redes con este tipo de tecnología, así como los principales parámetros que deben ser validados en una prueba de aceptación de estos sistemas, con vistas a pasar las rigorosas pruebas que exigen los Órganos Reguladores para garantizar la coexistencia armoniosa de esta novedosa tecnología con otras ya presentes en nuestras Redes de Telecomunicaciones. Finalmente se muestran algunos diseños que facilitan brindar a través de estos sistemas un servicio Triple Play, a los operadores de telecomunicaciones, con orientación al uso de la baja tensión y mas específicamente hacia el interior de las edificaciones, donde el tendido eléctrico es propiedad del dueño del inmueble, permitiendo de esta manera a los Operadores de Telecomunicaciones tener un completo acceso a la Red, facilitándoles una acción inmediata ante

  18. Comparative response time and fault logging with a PLC and supervisory software and a standalone unit developed for recording

    Baldaconi, Ricardo H.; Costa, Fabio E. da

    2017-01-01

    The Cobalt-60 irradiator of IPEN / CNEN, a category IV facility, has a security system for inter locking doors or exposure of radioactive sources made simultaneously by a programmable logic controller (PLC) model S7-200 from Siemens and a relay logic. From a set of information, both systems work together opening doors or exposing the sources. All incoming and outgoing information are sent serially via EIA232 communication to a personal computer with Windows® platform for a supervisory program which provides the monitoring of the entire process by a synoptic table on the computer screen and is also intended to keep records of all events on the computer's hard drive. A deficiency was found for the process of sending events via serial communication (EIA232) from PLC to the supervisory program. When failure occurred in a very short time, the PLC always took the right decision, but the registration process that had to go through the Windows® timeshare lost the information. In the previous work developed a standalone electronics unit connected to the inputs and outputs of the security system, fully optocoupled to avoid any interference to the security system that records each event on a memory card. In this work, for checking the unit developed record time ability, transients incoming signals for simulating failures, were injected at security system inputs and the response time of security system, supervisory program and the autonomous unity were measured and compared. (author)

  19. Comparative response time and fault logging with a PLC and supervisory software and a standalone unit developed for recording

    Baldaconi, Ricardo H., E-mail: ricardohovacker@hotmail.com [Escola Senai Roberto Simonsen, Educação e Tecnologia, Sao Paulo, SP (Brazil); Costa, Fabio E. da, E-mail: fecosta@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    The Cobalt-60 irradiator of IPEN / CNEN, a category IV facility, has a security system for inter locking doors or exposure of radioactive sources made simultaneously by a programmable logic controller (PLC) model S7-200 from Siemens and a relay logic. From a set of information, both systems work together opening doors or exposing the sources. All incoming and outgoing information are sent serially via EIA232 communication to a personal computer with Windows® platform for a supervisory program which provides the monitoring of the entire process by a synoptic table on the computer screen and is also intended to keep records of all events on the computer's hard drive. A deficiency was found for the process of sending events via serial communication (EIA232) from PLC to the supervisory program. When failure occurred in a very short time, the PLC always took the right decision, but the registration process that had to go through the Windows® timeshare lost the information. In the previous work developed a standalone electronics unit connected to the inputs and outputs of the security system, fully optocoupled to avoid any interference to the security system that records each event on a memory card. In this work, for checking the unit developed record time ability, transients incoming signals for simulating failures, were injected at security system inputs and the response time of security system, supervisory program and the autonomous unity were measured and compared. (author)

  20. Voltage Control System of A DC Generator Using PLC

    Subrata CHATTOPADHYAY

    2008-06-01

    Full Text Available The voltage control system of a DC generator may suffer from high frequency oscillations without offset or low frequency oscillation with offset. A PID controller can eliminate both these errors. In the present paper, the voltage control system of a DC generator using a PLC based PID controller has been designed. Operation of PLC as a continuous controller has been described and the load characteristic of DC generator with and without controller have been determined experimentally and reported in this paper.

  1. Transforming PLC Programs into Formal Models for Verification Purposes

    Darvas, D; Blanco, E

    2013-01-01

    Most of CERN’s industrial installations rely on PLC-based (Programmable Logic Controller) control systems developed using the UNICOS framework. This framework contains common, reusable program modules and their correctness is a high priority. Testing is already applied to find errors, but this method has limitations. In this work an approach is proposed to transform automatically PLC programs into formal models, with the goal of applying formal verification to ensure their correctness. We target model checking which is a precise, mathematical-based method to check formalized requirements automatically against the system.

  2. Model-based automated testing of critical PLC programs.

    Fernández Adiego, B; Tournier, J-C; González Suárez, V M; Bliudze, S

    2014-01-01

    Testing of critical PLC (Programmable Logic Controller) programs remains a challenging task for control system engineers as it can rarely be automated. This paper proposes a model based approach which uses the BIP (Behavior, Interactions and Priorities) framework to perform automated testing of PLC programs developed with the UNICOS (UNified Industrial COntrol System) framework. This paper defines the translation procedure and rules from UNICOS to BIP which can be fully automated in order to hide the complexity of the underlying model from the control engineers. The approach is illustrated and validated through the study of a water treatment process.

  3. Development and Application of POSAFE-Q PLC Platform

    Lee, MyeongKyun; Song, SeungWhan; Yun, DongHwa

    2012-01-01

    The Safety-grade Programmable Logic Controller (PLC) Platform named POSAFE-Q was developed so that it meets the requirements of the Safety Class 1E, Quality Class 1, and Seismic Category I. Development process of the POSAFE-Q software developed in accordance with software life cycles. The POSAFE-Q meets safety and suitability for design are based on digital I and C laws, guidelines and technical standards. The POSAFE-Q PLC obtained approval for Topical Report from the Nuclear Safety and Security Commission in Korea. (author)

  4. First Experience with PLC, OPC and BridgeVIEW in the context of the HMPID liquid distribution prototype

    Maatta, E; CERN. Geneva; Swoboda, Detlef; Lecoeur, G

    1999-01-01

    The TESt (Test and Evaluation Station) [3] project consists in the construction of a stand alone unit for a specific sub-system of an ALICE detector in order to gain first experience with commercial products for detector control. Although the control system includes only a small number of devices and is designed for a particular application, it covers nevertheless all layers of a complete system and can be extended or used in different applications. The control system prototype has been implemented for the Perfluorohexane (C6F14) liquid distribution of the ALICE-HMPID (High-Momentum Particle IDentification)[5]. This report presents the experience acquired while developing the control system with off the shelf items: National Instruments BridgeVIEW [6] supervision software, SIEMENS PLC S7-300 [7] and the programming tool STEP 7. The OPC standard (OLE [12] for Process Control) [8] was used for the communication between BridgeVIEW and the PLC.

  5. 77 FR 6668 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2012-02-09

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... all Rolls-Royce plc RB211-Trent 500 series turbofan engines. This AD requires a one-time inspection of... RB211- Trent 560A2-61 turbofan engines that have not complied with Rolls- Royce plc Service Bulletin No...

  6. 78 FR 11976 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-02-21

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... (AD) for all Rolls-Royce plc (RR) RB211-524 series turbofan engines. That AD currently requires...-16724 (76 FR 40217, July 8, 2011), for all RR plc RB211-524 series turbofan engines. That AD required...

  7. PowerGen plc report and accounts 1994

    1994-01-01

    The annual report and accounts of PowerGen plc for the year 1994 are presented. Financial highlights are quoted, followed by the Chairman's statement, reviews by the Chief Executive and Financial Directors, reports by the Auditors and Directors, balance sheets and details of the consolidated profit and loss account and principal accounting policies. A four year summary and shareholder information are included. (UK)

  8. Multiprog Virtual Laboratory Applied to PLC Programming Learning

    Shyr, Wen-Jye

    2010-01-01

    This study develops a Multiprog virtual laboratory for a mechatronics education designed to teach how to programme a programmable logic controller (PLC). The study was carried out with 34 students in the Department of Industry Education and Technology at National Changhua University of Education in Taiwan. In total, 17 students were assigned to…

  9. Úzkopásmová PLC komunikace se standardy G3-PLC, PRIME a IEEE-1901.2

    Skrášek, Tomáš

    2015-01-01

    Diplomová práce pojednává o standardech úzkopásmové PLC komunikace. V teoretické části jsou popsány všechny dostupné OFDM standardy, mezi něž patří G3-PLC, PRIME, IEEE-1901.2 a G.hnem. Praktická část se zabývá standardy PRIME a G3-PLC. Dále je také porovnán systém OFDM se systémem komunikace na jedné nosné frekvenci v prostředí s reálným rušením. V poslední části je popsán návrh dvou firmware pro PLC modemy Texas Instruments TMDSPLCKIT-V3, které umožňují UART komunikaci a dálkový sběr dat. K ...

  10. Broadband PLC for Clustered Advanced Metering Infrastructure (AMI Architecture

    Augustine Ikpehai

    2016-07-01

    Full Text Available Advanced metering infrastructure (AMI subsystems monitor and control energy distribution through exchange of information between smart meters and utility networks. A key challenge is how to select a cost-effective communication system without compromising the performance of the applications. Current communication technologies were developed for conventional data networks with different requirements. It is therefore necessary to investigate how much of existing communication technologies can be retrofitted into the new energy infrastructure to cost-effectively deliver acceptable level of service. This paper investigates broadband power line communications (BPLC as a backhaul solution in AMI. By applying the disparate traffic characteristics of selected AMI applications, the network performance is evaluated. This study also examines the communication network response to changes in application configurations in terms of packet sizes. In each case, the network is stress-tested and performance is assessed against acceptable thresholds documented in the literature. Results show that, like every other communication technology, BPLC has certain limitations; however, with some modifications in the network topology, it indeed can fulfill most AMI traffic requirements for flexible and time-bounded applications. These opportunities, if tapped, can significantly improve fiscal and operational efficiencies in AMI services. Simulation results also reveal that BPLC as a backhaul can support flat and clustered AMI structures with cluster size ranging from 1 to 150 smart meters.

  11. Development of Remote Monitoring and a Control System Based on PLC and WebAccess for Learning Mechatronics

    Wen-Jye Shyr

    2013-02-01

    Full Text Available This study develops a novel method for learning mechatronics using remote monitoring and control, based on a programmable logic controller (PLC and WebAccess. A mechatronics module, a Web-CAM and a PLC were integrated with WebAccess software to organize a remote laboratory. The proposed system enables users to access the Internet for remote monitoring and control of the mechatronics module via a web browser, thereby enhancing work flexibility by enabling personnel to control mechatronics equipment from a remote location. Mechatronics control and long-distance monitoring were realized by establishing communication between the PLC and WebAccess. Analytical results indicate that the proposed system is feasible. The suitability of this system is demonstrated in the department of industrial education and technology at National Changhua University of Education, Taiwan. Preliminary evaluation of the system was encouraging and has shown that it has achieved success in helping students understand concepts and master remote monitoring and control techniques.

  12. Bird strike and electrocutions at power lines, communication towers, and wind turbines: state of the art and state of the science - next steps toward mitigation

    Albert M. Manville II

    2005-01-01

    Migratory birds suffer considerable human-caused mortality from structures built to provide public services and amenities. Three such entities are increasing nationwide: communication towers, power lines, and wind turbines. Communication towers have been growing at an exponential rate over at least the past 6 years. The U.S. Fish and Wildlife Service is especially...

  13. Multiple-valued logic-protected coding for an optical non-quantum communication line

    Antipov, A. L.; Bykovsky, A. Yu.; Vasiliev, N. A.; Egorov, A. A.

    2006-01-01

    A simple and cheap method of secret coding in an optical line is proposed based on multiple-valued logic. This method is shown to have very high cryptography resources and is designated for bidirectional information exchange in a team of mobile robots, where quantum teleportation coding cannot yet

  14. Dynamic Characteristics of Communication Lines with Distributed Parameters to Control the Throttle-controlled Hydraulic Actuators

    D. N. Popov

    2015-01-01

    Full Text Available The article considers a mathematical model of the hydraulic line for remote control of electro-hydraulic servo drive (EHSD with throttle control. This type of hydraulic lines is designed as a backup to replace the electrical connections, which are used to control EHSD being remote from the site with devices located to form the control signals of any object. A disadvantage of electric connections is that they are sensitive to magnetic fields and thereby do not provide the required reliability of the remote control. Hydraulic lines have no this disadvantage and therefore are used in aircraft and other industrial systems. However, dynamic characteristics of hydraulic systems still have been investigated insufficiently in the case of transmitting control signals at a distance at which the signal may be distorted when emerging the wave processes.The article results of mathematical simulation, which are verified through physical experimentation, largely eliminate the shortcomings of said information.The mathematical model described in the paper is based on the theory of unsteady pressure compressible fluids. In the model there are formulas that provide calculation of frequency characteristics of the hydraulic lines under hydraulic oscillations of the laminar flow parameters of viscous fluid.A real mock-up of the system under consideration and an experimental ad hoc unit are used to verify the results of mathematically simulated hydraulic systems.Calculated logarithmic amplitude and phase frequency characteristics compared with those obtained experimentally prove, under certain conditions, the proposed theoretical method of calculation. These conditions have to ensure compliance with initial parameters of fluid defined under stationary conditions. The applied theory takes into consideration a non-stationary hydraulic resistance of the line when calculating frequency characteristics.The scientific novelty in the article material is presented in

  15. Electronic Support Groups: An Open Line of Communication in Contested Illness.

    Murphy, Michael; Kontos, Nicholas; Freudenreich, Oliver

    Patients with functional somatic syndromes are often difficult to treat. The relationship between doctors and patients can be strained, which limits communication. Instead, patients often communicate with each other over the Internet in electronic support groups. This perspective summarizes studies of patient-to-patient communication over the Internet and uses the concept of contested illness to provide insights into the experiences of patients with functional somatic disorders. Conflict between a patient and their physician is a key feature of functional somatic syndromes. Physicians and patients do not have a shared understanding or appreciation of the patient's experiences. Patients with functional somatic syndromes often value their own embodied experience over medical knowledge. At the same time, they remain deeply invested in finding a "good doctor" who believes that the patient is suffering, agrees with their conception of the cause, and assents to the treatment as directed by the patient. Electronic support groups reinforce these beliefs. Patients may benefit from a compromising, collaborative approach that is realistic about the limitations of medical knowledge. However, physicians should not engage in unsafe treatment practices. Electronic support groups exist for a wide range of illnesses and the issues that rise to the surface in functional somatic syndromes likely occur to some extent with almost every patient. Copyright © 2016 The Academy of Psychosomatic Medicine. Published by Elsevier Inc. All rights reserved.

  16. Circuit for Communication over DC Power Line Using High Temperature Electronics

    Krasowski, Michael J. (Inventor); Prokop, Norman F. (Inventor)

    2014-01-01

    A high temperature communications circuit includes a power conductor for concurrently conducting electrical energy for powering circuit components and transmitting a modulated data signal, and a demodulator for demodulating the data signal and generating a serial bit stream based on the data signal. The demodulator includes an absolute value amplifier for conditionally inverting or conditionally passing a signal applied to the absolute value amplifier. The absolute value amplifier utilizes no diodes to control the conditional inversion or passing of the signal applied to the absolute value amplifier.

  17. Development of the safety PLC for plant protection system

    Kim, Chang Hwoi; Lee, Dong Young [Korea Atomic Energy Research Institute, Taejeon (Korea, Republic of)

    2005-11-15

    The safety PLC (POSAFE-Q) is developing in the Korea Nuclear Instrumentation and Control System (KNICS) R and D project. The PLC satisfies Safety Class 1E, Quality Class 1, and Seismic Category I. The software such as RTOS and firmware are developed according to safety critical software life cycle. Especially, the formal method is applied to design SRS (Software Requirement Spec.) and SDS (Software Design Specification.) for error-free. The developed software according to software life cycle is verified by independent software V and V team. The overall response time from an input to the outputs shall be 50ms or less. The prototype for the POSAFE-Q was developed and functional testing and equipment qualification tests have been underway.

  18. Bringing Automated Formal Verification to PLC Program Development

    Fernández Adiego, Borja; Blanco Viñuela, Enrique

    Automation is the field of engineering that deals with the development of control systems for operating systems such as industrial processes, railways, machinery or aircraft without human intervention. In most of the cases, a failure in these control systems can cause a disaster in terms of economic losses, environmental damages or human losses. For that reason, providing safe, reliable and robust control systems is a first priority goal for control engineers. Ideally, control engineers should be able to guarantee that both software and hardware fulfill the design requirements. This is an enormous challenge in which industry and academia have been working and making progresses in the last decades. This thesis focuses on one particular type of control systems that operates industrial processes, the PLC (Programmable Logic Controller) - based control systems. Moreover it targets one of the main challenges for these systems, guaranteeing that PLC programs are compliant with their specifications. Traditionally ...

  19. British Nuclear Fuels plc: report and accounts 1987-88

    1989-01-01

    The Energy Committee has considered the report and accounts of BNFL (British Nuclear Fuels PLC) for the year 1987-88. The report looks at BNFL as a government owned PLC - its activities and financial performance. Various questions are raised about the underlying financial position justifying the optimism portrayed in the report and accounts. The impact of cost-plus contracts on UK customers is examined. The economics of THORP (Thermal Oxide Reprocessing Plant) are also examined especially as the escalation in the cost of constructing THORP means that a substantial loss will be made in the reprocessing of waste for which contracts were signed in the late 1960s or early 1970s. The main conclusions of the report are summarized. One of these is that the UK must be cautious about becoming a repository of foreign nuclear waste. Other specific recommendations are made - some about the decommissioning of BNFL plant. (UK)

  20. Autonomous Control Strategy of DC Microgrid for Islanding Mode Using Power Line Communication

    Dong-Keun Jeong

    2018-04-01

    Full Text Available This paper proposes a DC-bus signaling (DBS method for autonomous power management in a DC microgrid, used to improve its reliability. Centralized power management systems require communication between the power sources and loads. However, the DBS method operates based on the common DC-bus voltage and does not require communication. Based on the DC-bus voltage band, the DC-bus voltage can be used to inform the status of the DC-bus in various scenarios. The DC microgrid operates independently to maintain the system stably in the DC-bus voltage band. The DC microgrid can be divided into a grid-connected mode and an islanding mode. This paper proposes a control strategy based on power management of various independent components in islanding mode. In addition, the autonomous control method for switching the converter’s operation between grid-connected mode and islanding mode is proposed. A DC microgrid test bed consisting of a grid-connected AC/DC converter, a bidirectional DC/DC converter, a renewable energy simulator, DC home appliances and a DC-bus protector is used to test the proposed control strategy. The proposed autonomous control strategy is experimentally verified using the DC microgrid test bed.

  1. Implementation of PID autotuning procedure in PLC controller

    Daniun Marcin

    2017-01-01

    Full Text Available In this paper, we present the automatic PID tuning procedure based on the Method of Moments and AMIGO tuning rules. The advantage of the Method of Moments is that the time constant and transport delay are estimated at the areas rather than on the individual points. This results in high resistance to the measurement noises. The sensitivity to measurement noises is a serious problem in other autotuning methods. The second advantage of this method is that it approximates plant during identification process to first order model with time delay. We combined the Method of Moments with the AMIGO tuning rules and implemented this combination as a stand-alone autotuning procedure in Siemens S7-1200 PLC controller. Next, we compared this method with two built-in PID autotuning procedures which were available in Siemens S7-1200 PLC controller. The procedure was tested for three types of plant models: with lag-dominated, balanced, and delay-dominated dynamics. We simulated the plants on a PC in Matlab R2013a. The connection between the PC and PLC was maintained through a National Instruments data acquisition board, NI PCI-6229. We conducted tests for step change in the set point, trajectory tracking, and load disturbances. To assess control quality, we used IAE index. We limited our research to PI algorithm. The results prove that proposed method was better than two built-in tuning methods provided by Siemens, oscillating between a few and even a dozen percent in most cases. The proposed method is universal and can be implemented in any PLC controller.

  2. Fifth Baltic Sea pollution load compilation (PLC-5)

    Knuuttila, S.; Svendsen, L. M.; Staaf, H.; Kotilainen, P.; Boutrup, S.; Pyhala, M.; Durkin, M.

    2011-07-01

    This report includes the main results from the Fifth Pollution Load Compilation abbreviated PLC-5. It includes quantified annual waterborne total loads (from rivers, unmonitored and coastal areas as well as direct point and diffuse sources discharging directly to the Baltic Sea) from 1994 to 2008 to provide a basis for evaluating any decreasing (or increasing) trends in the total waterborne inputs to the Baltic Sea. Chapter 1 contains the objectives of PLC and the framework on classification of inputs and sources. Chapter 2 includes a short description of the Baltic Sea catchment area, while the methods for quantification and analysis together with quality assurance topics are briefly introduced in Chapter 3. More detailed information on methodologies is presented in the PLC-5 guidelines (HELCOM 2006). Chapter 4 reports the total inputs to the Baltic Sea of nutrients and selected heavy metals. Furthermore, the results of the quatification of discharges and losses of nitrogen and phosphorus from point and diffuse sources into inland surface waters within the Baltic Sea catchment area (source-oriented approach or gross loads) as well as the total load to the maritime area (load-oriented approarch or net loads) in 2006 are shown. Typically, results are presented by country and by main Baltic Sea sub-region. In Chapter 5, flow normalization is introduced and the results of trend analyses on 1994-2008 time series data on total waterborne loads of nitrogen and phosphorus are given together with a first evaluation of progress in obtaining the provisional reduction targets by country and by main Baltic Sea sub-region. Chapter 6 includes discussion of some of the main conclusions and advice for future PLCs. The annexes contain the flow-normalized annual load data and figures and tables with results from the PLC-5.

  3. Automatic control model of water filling system with Allen Bradley Micrologix 1400 PLC

    Harahap, R.; Adyatma, AF; Fahmi, F.

    2018-02-01

    Programmable Logic Controller or PLC today plays an important role in most industrial control systems. PLC usage can be encountered in almost all fields of industry, not only in the manufacturing world but also on many other things such as elevators in office buildings, hotels hospitals, and others. PLC is an electronic control tool that operates in logic that its programming can be modified with relative ease. As with any controller in general, the PLC processes input signals to further discharge output according to the desired program. PLC usage is very broad because of its high reliability, can be reprogrammed or modified with relative ease, and very helpful in the tracking troubleshooting. One type of existing PLC is Allen Bradley PLC. Allen Bradley PLC program is commonly used in various industries. PLC Allen Bradley (AB) has several types, and one of them is the type of Micrologic 1400. In this study we design a system as a comparison with the conventional system. For that to explore the use of a PLC program which will be supported by a simulator tool, including a program to RSLogic 500, how to programming, monitoring via RSView32, and modification. It is expected to understand the application aspect of operation and programming of this specific PLC and its potential. The purpose of this research is to design water filling automation system by using Allen Bradley Micrologic 1400 type 1766-L32BXB PLC, empowering the use of Allen Bradley Micrologic 1400 PLC and to regulate the desired process to obtain efficiency and effectiveness compared with conventional system arrangement using Relay.

  4. Webová aplikace v PLC PFC200

    Michalík, David

    2017-01-01

    Tato bakalářská práce se věnuje implementaci vlastního způsobu ovládání vstupů, výstupů a paměti PLC PFC200 od firmy WAGO pomocí dynamického webového rozhraní. Součástí práce je popis PLC, způsobů jeho ovládání, rešerše volně dostupných webových serverů pro Linux a popis metod pro vytvoření real-time ovládání. Výstupem je webová aplikace běžící na webovém serveru v PLC, využívající vlastní runtime systém formou daemon programů. This bachelor’s thesis is mainly focused on implementation of ...

  5. PLC based control system and maintenance activities at NCAR, Bilaspur

    Dewangan, Jaidev; Trivedi, T.; Patel, Shiv P.; Malik, C.; Kumar, Rakesh; Gupta, Santosh Kumar; Bajpai, P.K.

    2015-01-01

    A 3.0 MV high current low energy Pelletron Accelerator facility (Model 9SDH-4, NEC, USA) with TORUIS (ion source for H + and He 2+ beam current H + ion ∼ 50μA @ 6 MeV, He 2+ at ∼ 10μA) and SNICS-II ion source for heavy ions has been commissioned as 'National Centre for Accelerator Based Research' in the Department of Pure and Applied Physics, Guru Ghasidas Vishwavidyalaya. In this paper, we detail out the control system developed and implemented at NCAR. The basic idea of controlling the machine is by providing the output signal through PLC to ACPC of accelerator using user interface points provided by the manufacturer. The PLC based system generates output signal once it receives the feedback signals from search and secure switches, door lock switches and scram switches interlocked with PLC. The output is controlled by ladder logic and is activated only when all the radiation monitors are in healthy state and outside radiations monitor having low radiation level. The details of control system and maintenance activities will be discussed in the paper

  6. Fault tree synthesis for software design analysis of PLC based safety-critical systems

    Koo, S. R.; Cho, C. H.; Seong, P. H.

    2006-01-01

    As a software verification and validation should be performed for the development of PLC based safety-critical systems, a software safety analysis is also considered in line with entire software life cycle. In this paper, we propose a technique of software safety analysis in the design phase. Among various software hazard analysis techniques, fault tree analysis is most widely used for the safety analysis of nuclear power plant systems. Fault tree analysis also has the most intuitive notation and makes both qualitative and quantitative analyses possible. To analyze the design phase more effectively, we propose a technique of fault tree synthesis, along with a universal fault tree template for the architecture modules of nuclear software. Consequently, we can analyze the safety of software on the basis of fault tree synthesis. (authors)

  7. Carrier Current Line Systems Technologies in M2M Architecture for Wireless Communication

    Hua-Ching Chen

    2016-01-01

    Full Text Available This paper investigates the Carrier Current Line Systems (CCLS technologies of Machine to Machine (M2M architecture which applied for mobile station coverage working with metro, high speed railway, and subway such as analysis for public transport of an indoor transition system. It is based on the theory and practical engineering principle which provide guidelines and formulas for link budget design to help designers fully control and analyze the single output power of uplink and downlink between Fiber Repeaters (FR and mobile station as well as base station. Finally, the results of this leakage cable system are successfully applied to indoor coverage design for metro rapid transit system which are easily installed cellular over fiber solutions for WCDMA/LTE access is becoming Ubiquitous Network to Internet of Thing (IOT real case hierarchy of telecommunication.

  8. Joint terminals and relay optimization for two-way power line information exchange systems with QoS constraints

    Wu, Xiaolin; Rong, Yue

    2015-12-01

    The quality-of-service (QoS) criteria (measured in terms of the minimum capacity requirement in this paper) are very important to practical indoor power line communication (PLC) applications as they greatly affect the user experience. With a two-way multicarrier relay configuration, in this paper we investigate the joint terminals and relay power optimization for the indoor broadband PLC environment, where the relay node works in the amplify-and-forward (AF) mode. As the QoS-constrained power allocation problem is highly non-convex, the globally optimal solution is computationally intractable to obtain. To overcome this challenge, we propose an alternating optimization (AO) method to decompose this problem into three convex/quasi-convex sub-problems. Simulation results demonstrate the fast convergence of the proposed algorithm under practical PLC channel conditions. Compared with the conventional bidirectional direct transmission (BDT) system, the relay-assisted two-way information exchange (R2WX) scheme can meet the same QoS requirement with less total power consumption.

  9. Supporting narrative retells for people with aphasia using augmentative and alternative communication: photographs or line drawings? Text or no text?

    Griffith, Julie; Dietz, Aimee; Weissling, Kristy

    2014-05-01

    The purpose of this study was to examine how the interface design of an augmentative and alternative communication (AAC) device influences the communication behaviors of people with aphasia during a narrative retell task. A case-series design was used. Four narratives were created on an AAC device with combinations of personally relevant (PR) photographs, line drawings (LDs), and text for each participant. The narrative retells were analyzed to describe the expressive modality units (EMUs) used, trouble sources experienced, and whether trouble sources were repaired. The researchers also explored the participants' perceived helpfulness of the interface features. The participants primarily used spoken EMUs to retell their narratives. They relied on PR photographs more frequently than LDs; however, they reported both picture types to be equally helpful. Text was frequently used and reported as helpful by all 4 people with aphasia. Participants experienced similar rates of trouble sources across conditions; however, they displayed unique trends for successful repairs of trouble sources. For narrative retells, LDs may serve as an effective visual support when PR photographs are unavailable. Individual assessment is necessary to determine the optimum combination of supports in AAC systems for people with aphasia.

  10. Development of a measurement and control system for a 10 kW@20 K refrigerator based on Siemens PLC S7-300

    Li, J.; Liu, L. Q.; Liu, T.; Xu, X. D.; Dong, B.; Lu, W. H.; Pan, W.; Wu, J. H.; Xiong, L. Y.

    2017-02-01

    A 10 kW@20 K refrigerator has been established by the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. A measurement and control system based on Siemens PLC S7-300 for this 10 kW@20 K refrigerator is developed. According to the detailed measurement requirements, proper sensors and transmitters are adopted. Siemens S7-300 PLC CPU315-2 PN/DP operates as a master station. Two sets of ET200M DP remote expand I/O, one power meter, two compressors and one vacuum gauge operate as slave stations. Profibus-DP field communication and Modbus communication are used between the master station and the slave stations in this control system. The upper computer HMI (Human Machine Interface) is compiled using Siemens configuration software WinCC V7.0. The upper computer communicates with PLC by means of industrial Ethernet. After commissioning, this refrigerator has been operating with a 10 kW of cooling power at 20 K for more than 72 hours.

  11. Emulation of Narrowband Powerline Data Transmission Channels and Evaluation of PLC Systems

    Liu, Wenqing

    2013-01-01

    This work proposes advanced emulation of the physical layer behavior of NB-PLC channels and the application of a channel emulator for the evaluation of NB-PLC systems. In addition, test procedures and reference channels are proposed to improve efficiency and accuracy in the system evaluation and classification. This work shows that the channel emulator-based solution opens new ways toward flexible, reliable and technology-independent performance assessment of PLC modems.

  12. Machine interlock and protection system based on PLC for the SSRF linac

    Chou Wenjun; Zhou Dayong; Chen Jianfeng; Shen Liren; Liu Yajuan

    2008-01-01

    This paper describes a machine interlock and protection system used for accelerators based on EPICS (Experimental physics and industrial control system). The system is composed of a front-end computer and an FM-3R logic controller PLC. The alarm signal is passed by the hardware directly, and would be deal with PLC. The reporting, recording and analyst of the event are accomplished by EPICS control software. And PLC is linked to the EPICS by Internet. (authors)

  13. Secure and Time-Aware Communication of Wireless Sensors Monitoring Overhead Transmission Lines.

    Mazur, Katarzyna; Wydra, Michal; Ksiezopolski, Bogdan

    2017-07-11

    Existing transmission power grids suffer from high maintenance costs and scalability issues along with a lack of effective and secure system monitoring. To address these problems, we propose to use Wireless Sensor Networks (WSNs) as a technology to achieve energy efficient, reliable, and low-cost remote monitoring of transmission grids. With WSNs, smart grid enables both utilities and customers to monitor, predict and manage energy usage effectively and react to possible power grid disturbances in a timely manner. However, the increased application of WSNs also introduces new security challenges, especially related to privacy, connectivity, and security management, repeatedly causing unpredicted expenditures. Monitoring the status of the power system, a large amount of sensors generates massive amount of sensitive data. In order to build an effective Wireless Sensor Network (WSN) for a smart grid, we focus on designing a methodology of efficient and secure delivery of the data measured on transmission lines. We perform a set of simulations, in which we examine different routing algorithms, security mechanisms and WSN deployments in order to select the parameters that will not affect the delivery time but fulfill their role and ensure security at the same time. Furthermore, we analyze the optimal placement of direct wireless links, aiming at minimizing time delays, balancing network performance and decreasing deployment costs.

  14. A study of PLC system vulnerability checklists in nuclear power plants

    Cha, Ki Jong; Cho, Gi Ho; Ahn, Jaeh Young; Kim, Young Mi; Kwon, Yong Il

    2012-01-01

    Because the design of the PLCs (Programmable Logic Controller) in the I and C (Instrument and Control) systems for NPP (Nuclear Power Plant) were carried out independently, the problems of cyber security were not addressed in the PLC system designs. Recently, the analysis and the countermeasure development for the PLC systems became mandatory due to the developments in cyber attack techniques and the increasingly revealed vulnerability to such attacks. A comparative analysis on the cyber security checklist of PLC in industry control system and in NPP systems was carried out, and in this paper, the cyber security regulatory trend and the PLC usage status are described

  15. A study of PLC system vulnerability checklists in nuclear power plants

    Cha, Ki Jong; Cho, Gi Ho; Ahn, Jaeh Young [Convergence technology Research Commercialization Center, Daejeon (Korea, Republic of); Kim, Young Mi; Kwon, Yong Il [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2012-10-15

    Because the design of the PLCs (Programmable Logic Controller) in the I and C (Instrument and Control) systems for NPP (Nuclear Power Plant) were carried out independently, the problems of cyber security were not addressed in the PLC system designs. Recently, the analysis and the countermeasure development for the PLC systems became mandatory due to the developments in cyber attack techniques and the increasingly revealed vulnerability to such attacks. A comparative analysis on the cyber security checklist of PLC in industry control system and in NPP systems was carried out, and in this paper, the cyber security regulatory trend and the PLC usage status are described.

  16. Line facilities outline

    1998-08-01

    This book deals with line facilities. The contents of this book are outline line of wire telecommunication ; development of line, classification of section of line and theory of transmission of line, cable line ; structure of line, line of cable in town, line out of town, domestic cable and other lines, Optical communication ; line of optical cable, transmission method, measurement of optical communication and cable of the sea bottom, Equipment of telecommunication line ; telecommunication line facilities and telecommunication of public works, construction of cable line and maintenance and Regulation of line equipment ; regulation on technique, construction and maintenance.

  17. Embedded PLC Webserver and Possibilities of its Utilization

    Kopček, Michal

    2016-12-01

    The concept Industry 4.0 is a top theme of recent times. Even if it represents the so-called 4th industrial revolution its main ideas could be used also to support the education of subjects from IT and automation. Furthermore, the basic IT and web technologies inherited by this concept are very well known to students. This paper introduces the embedded webserver of PLC and the options for its optimal utilization. The web server is essentially a simple and widely well-known technology, therefore it was chosen as an example.

  18. AUTOMATION OF GLASS TEMPERING FURNACE BY USING PLC

    Abdullah BÜYÜKYILDIZ

    2007-02-01

    Full Text Available In this study, a furnace which is used for observation of environments under high temperature, and also used for manufacturing of glasses which are resisted to high temperature has been designed and implemented. Automation of this system has been done by using PLC. Operating parameters of furnace such as materials entering, the furnace, the local temperature control of furnace, cooling control and materials outing have been sensed with Hall Effect Sensor. Furthermore, the observation of parameters of furnace on screen has been provided with SCADA software. Obtained products have been shown the system works successfully.

  19. Embedded PLC Webserver and Possibilities of its Utilization

    Kopček Michal

    2016-12-01

    Full Text Available The concept Industry 4.0 is a top theme of recent times. Even if it represents the so-called 4th industrial revolution its main ideas could be used also to support the education of subjects from IT and automation. Furthermore, the basic IT and web technologies inherited by this concept are very well known to students. This paper introduces the embedded webserver of PLC and the options for its optimal utilization. The web server is essentially a simple and widely well-known technology, therefore it was chosen as an example.

  20. Embedded PLC Webserver and Possibilities of its Utilization

    Kopček Michal

    2016-01-01

    The concept Industry 4.0 is a top theme of recent times. Even if it represents the so-called 4th industrial revolution its main ideas could be used also to support the education of subjects from IT and automation. Furthermore, the basic IT and web technologies inherited by this concept are very well known to students. This paper introduces the embedded webserver of PLC and the options for its optimal utilization. The web server is essentially a simple and widely well-known technology, therefo...

  1. A water pumping control system with a programmable logic controller (PLC) and industrial wireless modules for industrial plants--an experimental setup.

    Bayindir, Ramazan; Cetinceviz, Yucel

    2011-04-01

    This paper describes a water pumping control system that is designed for production plants and implemented in an experimental setup in a laboratory. These plants contain harsh environments in which chemicals, vibrations or moving parts exist that could potentially damage the cabling or wires that are part of the control system. Furthermore, the data has to be transferred over paths that are accessible to the public. The control systems that it uses are a programmable logic controller (PLC) and industrial wireless local area network (IWLAN) technologies. It is implemented by a PLC, an communication processor (CP), two IWLAN modules, and a distributed input/output (I/O) module, as well as the water pump and sensors. Our system communication is based on an Industrial Ethernet and uses the standard Transport Control Protocol/Internet Protocol for parameterisation, configuration and diagnostics. The main function of the PLC is to send a digital signal to the water pump to turn it on or off, based on the tank level, using a pressure transmitter and inputs from limit switches that indicate the level of the water in the tank. This paper aims to provide a convenient solution in process plants where cabling is not possible. It also has lower installation and maintenance cost, provides reliable operation, and robust and flexible construction, suitable for industrial applications. Copyright © 2010 ISA. Published by Elsevier Ltd. All rights reserved.

  2. Development of a Measurement and Control System for a 40l/h Helium Liquefier based on Siemens PLC S7-300

    Li, J.; Liu, L. Q.; Xu, X. D.; Liu, T.; Li, Q.; Hu, Z. J.; Wang, B. M.; Xiong, L. Y.; Dong, B.; Yan, T.

    A 40l/h Helium Liquefier has been commissioned by the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. A measurement and control system based on Siemens PLC S7-300 for this Helium Liquefier is developed. Proper sensors are selected, for example, three types of transmitters are adopted respectively according to detailed temperature measurement requirements. Siemens S7-300 PLC CPU315-2PN/DP operates as a master station and three sets of ET200 M DP remote expand I/O operate asslave stations. Profibus-DP field communication is used between the master station and the slave stations. The upper computer HMI(Human Machine Interface) is compiled using Siemens configuration software WinCC V7.0. The upper computer communicates with PLC by means of industrial Ethernet. A specific control logic for this Helium Liquefier is developed. The control of the suction and discharge pressures of the compressor and the control of the turbo-expanders loop are being discussed in this paper. Following the commissioning phase, the outlet temperature of the second stage turbine has reached 8.6K and the temperature before the throttle valve has reached 13.1K.

  3. Measurement and control system for cryogenic helium gas bearing turbo-expander experimental platform based on Siemens PLC S7-300

    Li, J.; Xiong, L. Y.; Peng, N.; Dong, B.; Wang, P.; Liu, L. Q.

    2014-01-01

    An experimental platform for cryogenic Helium gas bearing turbo-expanders is established at the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. This turbo-expander experimental platform is designed for performance testing and experimental research on Helium turbo-expanders with different sizes from the liquid hydrogen temperature to the room temperature region. A measurement and control system based on Siemens PLC S7-300 for this turbo-expander experimental platform is developed. Proper sensors are selected to measure such parameters as temperature, pressure, rotation speed and air flow rate. All the collected data to be processed are transformed and transmitted to S7-300 CPU. Siemens S7-300 series PLC CPU315-2PN/DP is as master station and two sets of ET200M DP remote expand I/O is as slave station. Profibus-DP field communication is established between master station and slave stations. The upper computer Human Machine Interface (HMI) is compiled using Siemens configuration software WinCC V6.2. The upper computer communicates with PLC by means of industrial Ethernet. Centralized monitoring and distributed control is achieved. Experimental results show that this measurement and control system has fulfilled the test requirement for the turbo-expander experimental platform.

  4. Measurement and control system for cryogenic helium gas bearing turbo-expander experimental platform based on Siemens PLC S7-300

    Li, J.; Xiong, L. Y.; Peng, N.; Dong, B.; Liu, L. Q. [Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190 (China); Wang, P. [Beijing Sciample Technology Co., Ltd., Beijing, 100190 (China)

    2014-01-29

    An experimental platform for cryogenic Helium gas bearing turbo-expanders is established at the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. This turbo-expander experimental platform is designed for performance testing and experimental research on Helium turbo-expanders with different sizes from the liquid hydrogen temperature to the room temperature region. A measurement and control system based on Siemens PLC S7-300 for this turbo-expander experimental platform is developed. Proper sensors are selected to measure such parameters as temperature, pressure, rotation speed and air flow rate. All the collected data to be processed are transformed and transmitted to S7-300 CPU. Siemens S7-300 series PLC CPU315-2PN/DP is as master station and two sets of ET200M DP remote expand I/O is as slave station. Profibus-DP field communication is established between master station and slave stations. The upper computer Human Machine Interface (HMI) is compiled using Siemens configuration software WinCC V6.2. The upper computer communicates with PLC by means of industrial Ethernet. Centralized monitoring and distributed control is achieved. Experimental results show that this measurement and control system has fulfilled the test requirement for the turbo-expander experimental platform.

  5. Commercial information system of Slovak Electricity Transmission System, Plc

    Laznicka, L.

    2004-01-01

    Commercial Information System (CIS), which main role of is to support the commercial activities of the company, is built up by business department of SEPS, Plc in close co-operation with the supplier company Sfera, Plc. The system entries are data from electricity meters obtained by automatized data acquisition and from bugging sheets, contractual hour diagrams, parameters of transmission system like measuring schemes and formulas for calculation of demand and supply, contractual data resulting from agreements, business conditions, URSO decisions and valid legislative. A part of the system is also support of process of data evaluation like calculation of transmitted energy quantity, calculation of actual output diagrams, comparison of actual and contractual diagrams, calculation of system divergence, calculation of demand divergence, etc. The final price for the drawings of services, which are joined with transmission of the electric power will be determined by the accounting process. In this causality there are automatically made out invoices for access, losses, system charges, system services, short-term and long-term transits, divergences and for cross-border transmission auctions. System also generates various specialized synopses and statistics for the evaluation requirements of important aspects and for parameter observations. Successive liberalisation of the electricity power market, changes in legislative and URSO decisions require CIS to be sufficiently configurable and to adapt flexible on the alternating environs. (author)

  6. File list: Pol.Plc.50.RNA_Polymerase_III.AllCell [Chip-atlas[Archive

    Full Text Available Pol.Plc.50.RNA_Polymerase_III.AllCell mm9 RNA polymerase RNA Polymerase III Placent...a http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Pol.Plc.50.RNA_Polymerase_III.AllCell.bed ...

  7. File list: Pol.Plc.50.RNA_polymerase_II.AllCell [Chip-atlas[Archive

    Full Text Available Pol.Plc.50.RNA_polymerase_II.AllCell hg19 RNA polymerase RNA polymerase II Placenta... http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Plc.50.RNA_polymerase_II.AllCell.bed ...

  8. File list: Pol.Plc.20.RNA_polymerase_III.AllCell [Chip-atlas[Archive

    Full Text Available Pol.Plc.20.RNA_polymerase_III.AllCell hg19 RNA polymerase RNA polymerase III Placen...ta http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Plc.20.RNA_polymerase_III.AllCell.bed ...

  9. File list: Pol.Plc.10.RNA_polymerase_II.AllCell [Chip-atlas[Archive

    Full Text Available Pol.Plc.10.RNA_polymerase_II.AllCell hg19 RNA polymerase RNA polymerase II Placenta... http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Plc.10.RNA_polymerase_II.AllCell.bed ...

  10. File list: Pol.Plc.10.RNA_polymerase_III.AllCell [Chip-atlas[Archive

    Full Text Available Pol.Plc.10.RNA_polymerase_III.AllCell hg19 RNA polymerase RNA polymerase III Placen...ta http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Plc.10.RNA_polymerase_III.AllCell.bed ...

  11. File list: Pol.Plc.05.RNA_polymerase_II.AllCell [Chip-atlas[Archive

    Full Text Available Pol.Plc.05.RNA_polymerase_II.AllCell hg19 RNA polymerase RNA polymerase II Placenta... http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Plc.05.RNA_polymerase_II.AllCell.bed ...

  12. 77 FR 32007 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2012-05-31

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... all Rolls-Royce plc (RR) RB211-Trent 800 series turbofan engines. This AD requires removal from...-17, 877- 17, 884-17, 884B-17, 892-17, 892B-17, and 895-17 turbofan engines. (d) Reason This AD was...

  13. 77 FR 73268 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2012-12-10

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... certain Rolls-Royce plc (RR) RB211-Trent 900 series turbofan engines. This AD requires inspection of the... turbofan engines, all serial numbers. (d) Reason This AD was prompted by a Trent 900 engine experiencing a...

  14. 78 FR 17297 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-03-21

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... (AD) for all Rolls-Royce plc (RR) RB211 Trent 500 series turbofan engines. That AD currently requires... 9, 2012), for all RR RB211 Trent 500 series turbofan engines. That AD requires a one-time inspection...

  15. 78 FR 6749 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-01-31

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... (AD) for all Rolls-Royce plc (RR) models RB211 Trent 768-60, 772-60, and 772B-60 turbofan engines... 772B-60 turbofan engines. (d) Reason This AD was prompted by low-pressure (LP) compressor blade partial...

  16. 77 FR 56760 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2012-09-14

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... all Rolls-Royce plc (RR) RB211-Trent 800 series turbofan engines. This AD requires removing from...-17, 892-17, 892B-17, and 895-17 turbofan engines that have an intermediate pressure (IP) turbine disc...

  17. 77 FR 13485 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2012-03-07

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... series turbofan engines. This AD requires inspecting the front combustion liner head section for cracking.... (c) Applicability This AD applies to Rolls-Royce plc (RR) RB211-Trent 800 turbofan engines, all...

  18. Application of PLC technology in measurement of beam profile on 100 MeV accelerator

    Yu Luyang; Chinese Academy of Sciences, Beijing; Chen Yongzhong; Chen Yongzhong; Liu Dekang; Chinese Academy of Sciences, Beijing

    2005-01-01

    A comprehensive introduction is given to the real-time measuring method, which is based on the Programmable Logic Controller (PLC) technology and can measure intensity and profile of the beam by a scintillator screen. The whole system has many advantages, such as good reliability, high precision, intuitional measurement, etc. due to the use of the PLC and Labview software. (authors)

  19. 76 FR 80430 - Rio Tinto plc and Rio Tinto Limited; Notice of Application

    2011-12-23

    ... plc and Rio Tinto Limited; Notice of Application December 19, 2011. AGENCY: Securities and Exchange Commission (``Commission''). ACTION: Notice of application under section 3(b)(2) and 45(a) of the Investment Company Act of 1940 (the ``Act''). SUMMARY: Summary of Application: Rio Tinto plc (``RTP'') and Rio Tinto...

  20. Upgradation in SCADA and PLC of existing LN_2 control system for SST-1

    Panchal, Pradip; Mahesuria, Gaurang; Panchal, Rohit; Patel, Rakesh; Sonara, Dashrath; Pitroda, Dipen; Nimavat, Hiren; Tanna, Vipul; Pradhan, Subrata

    2016-01-01

    Highlights: • The control system of LN_2 Management System of SST-1 is designed on PLC and SCADA. • The implementation and results of up-gradation in PLC and SCADA are reported. • The up-gradation in PLC and SCADA has improved the reliability & availability of SST-1 LN_2 system. - Abstract: Helium Refrigerator/Liquefier system of Steady State Superconducting Tokamak (SST-1) incorporates Liquid Nitrogen (LN_2) pre-cooling system. LN_2 is used for 80 K thermal shields of SST-1, current feeder system and integrated flow distribution and control system. The LN_2 management system is distributed system and requires automatic control. Initially LN_2 control system had Citect based Supervisory Control and Data Acquisition (SCADA) and Koyo make Programmable Logic Controller (PLC). With the passage of time and due to unavailability of their hardware, it is being obsoleted. So, the requirements of new PLC and SCADA systems have been envisaged to make uninterruptable operation of SST-1 cryogenic system. Therefore, Wonderware SCADA and Schneider Electric make PLC is programmed to replace Citect SCADA and Koyo PLC. New control features have been added in upgraded control system for better management of LN_2 system. This upgradation of SCADA and PLC is completed, tested successfully and in operation. Operational performance highlights of the new upgraded system are presented in this paper.

  1. 75 FR 46864 - Airworthiness Directives; Short Brothers PLC Model SD3 Airplanes

    2010-08-04

    ...-0225; Directorate Identifier 2009-NM-203-AD] RIN 2120-AA64 Airworthiness Directives; Short Brothers PLC... this proposed AD, contact Short Brothers PLC, Airworthiness, P.O. Box 241, Airport Road, Belfast, BT3... amend this proposed AD based on those comments. We will post all comments we receive, without change, to...

  2. 75 FR 61114 - Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines

    2010-10-04

    ... Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines AGENCY: Federal Aviation.... Fax: (202) 493-2251. Contact Rolls-Royce plc, P.O. Box 31, Derby, England, DE248BJ; telephone: 011-44... AD. We will consider all comments received by the closing date and may amend this proposed AD based...

  3. 75 FR 264 - Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines

    2010-01-05

    ...-1004; Directorate Identifier 2009-NE-36-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc.... Contact Rolls-Royce plc, P.O. Box 31, Derby, England; telephone: 011-44-1332-249428; fax: 011-44-1332... AD. We will consider all comments received by the closing date and may amend this proposed AD based...

  4. 76 FR 2605 - Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines

    2011-01-14

    ... Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines AGENCY: Federal Aviation... holidays. Fax: (202) 493-2251. Contact Rolls-Royce plc, P.O. Box 31, DERBY, DE24 8BJ, UK; telephone 44 (0... AD. We will consider all comments received by the closing date and may amend this proposed AD based...

  5. 76 FR 24796 - Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines

    2011-05-03

    ... Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines AGENCY: Federal Aviation.... Request To Revise the Compliance Times Four commenters, American Airlines, Delta Airlines, Rolls-Royce plc... SNPRM were developed to minimize the risk of uncontained disc failure, based on the age of the parts in...

  6. 76 FR 52288 - Airworthiness Directives; Rolls-Royce plc (RR) Trent 800 Series Turbofan Engines

    2011-08-22

    ...-0836; Directorate Identifier 2010-NE-38-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR... plc, P.O. Box 31, Derby, DE24 8BJ, United Kingdom: telephone 44 (0) 1332 242424; fax 44 (0) 1332... based on those comments. We will post all comments we receive, without change, to http://www.regulations...

  7. Translation of PLC Programs to x86 for Simulation and Verification

    Sallai, Gyula

    2017-01-01

    PLC programs are written in special languages, variants of the languages defined in the IEC 61131 standard. These programs cannot be directly executed on personal computers (on x86 architecture). To perform simulation of the PLC program or diagnostics during development, either a real PLC or a PLC simulator has to be used. However, these solutions are often inflexible and they do not provide appropriate performance. By generating x86-representations (semantically equivalent programs which can be executed on PCs, e.g. written in C, C++ or Java) of the PLC programs, some of these challenges could be met. PLCverif is a PLC program verification tool developed at CERN which includes a parser for Siemens PLC programs. In this work, we describe a code generator based on this parser of PLCverif. This work explores the possibilities and challenges of generating programs in widely-used general purpose languages from PLC programs, and provides a proof-of-concept code generation implementation. The presented solution dem...

  8. Upgradation in SCADA and PLC of existing LN{sub 2} control system for SST-1

    Panchal, Pradip, E-mail: pradip@ipr.res.in; Mahesuria, Gaurang; Panchal, Rohit; Patel, Rakesh; Sonara, Dashrath; Pitroda, Dipen; Nimavat, Hiren; Tanna, Vipul; Pradhan, Subrata

    2016-11-15

    Highlights: • The control system of LN{sub 2} Management System of SST-1 is designed on PLC and SCADA. • The implementation and results of up-gradation in PLC and SCADA are reported. • The up-gradation in PLC and SCADA has improved the reliability & availability of SST-1 LN{sub 2} system. - Abstract: Helium Refrigerator/Liquefier system of Steady State Superconducting Tokamak (SST-1) incorporates Liquid Nitrogen (LN{sub 2}) pre-cooling system. LN{sub 2} is used for 80 K thermal shields of SST-1, current feeder system and integrated flow distribution and control system. The LN{sub 2} management system is distributed system and requires automatic control. Initially LN{sub 2} control system had Citect based Supervisory Control and Data Acquisition (SCADA) and Koyo make Programmable Logic Controller (PLC). With the passage of time and due to unavailability of their hardware, it is being obsoleted. So, the requirements of new PLC and SCADA systems have been envisaged to make uninterruptable operation of SST-1 cryogenic system. Therefore, Wonderware SCADA and Schneider Electric make PLC is programmed to replace Citect SCADA and Koyo PLC. New control features have been added in upgraded control system for better management of LN{sub 2} system. This upgradation of SCADA and PLC is completed, tested successfully and in operation. Operational performance highlights of the new upgraded system are presented in this paper.

  9. File list: Pol.Plc.05.RNA_polymerase_III.AllCell [Chip-atlas[Archive

    Full Text Available Pol.Plc.05.RNA_polymerase_III.AllCell hg19 RNA polymerase RNA polymerase III Placen...ta http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Plc.05.RNA_polymerase_III.AllCell.bed ...

  10. File list: Pol.Plc.20.RNA_polymerase_II.AllCell [Chip-atlas[Archive

    Full Text Available Pol.Plc.20.RNA_polymerase_II.AllCell hg19 RNA polymerase RNA polymerase II Placenta... http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Plc.20.RNA_polymerase_II.AllCell.bed ...

  11. File list: Pol.Plc.50.RNA_polymerase_III.AllCell [Chip-atlas[Archive

    Full Text Available Pol.Plc.50.RNA_polymerase_III.AllCell hg19 RNA polymerase RNA polymerase III Placen...ta http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Plc.50.RNA_polymerase_III.AllCell.bed ...

  12. File list: InP.Plc.50.Input_control.AllCell [Chip-atlas[Archive

    Full Text Available InP.Plc.50.Input_control.AllCell hg19 Input control Input control Placenta SRX19004...9,SRX080366 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/InP.Plc.50.Input_control.AllCell.bed ...

  13. File list: InP.Plc.20.Input_control.AllCell [Chip-atlas[Archive

    Full Text Available InP.Plc.20.Input_control.AllCell mm9 Input control Input control Placenta SRX112971...02,SRX404310,SRX1072160,SRX871507,SRX192097,SRX192098,SRX192099,SRX204148 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/InP.Plc.20.Input_control.AllCell.bed ...

  14. File list: InP.Plc.05.Input_control.AllCell [Chip-atlas[Archive

    Full Text Available InP.Plc.05.Input_control.AllCell hg19 Input control Input control Placenta SRX19004...9,SRX080366 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/InP.Plc.05.Input_control.AllCell.bed ...

  15. File list: InP.Plc.05.Input_control.AllCell [Chip-atlas[Archive

    Full Text Available InP.Plc.05.Input_control.AllCell mm9 Input control Input control Placenta SRX344647...160,SRX204147,SRX404310,SRX871506,SRX871507,SRX192098,SRX192097,SRX192099 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/InP.Plc.05.Input_control.AllCell.bed ...

  16. File list: InP.Plc.10.Input_control.AllCell [Chip-atlas[Archive

    Full Text Available InP.Plc.10.Input_control.AllCell mm9 Input control Input control Placenta SRX344648...310,SRX871506,SRX142911,SRX871507,SRX204148,SRX192098,SRX192097,SRX192099 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/InP.Plc.10.Input_control.AllCell.bed ...

  17. The Effects of Color Cues on Typically Developing Preschoolers' Speed of Locating a Target Line Drawing: Implications for Augmentative and Alternative Communication Display Design

    Thistle, Jennifer J.; Wilkinson, Krista

    2009-01-01

    Purpose: This research examined how the presence of color in relation to a target within an augmentative and alternative communication array influenced the speed with which typically developing preschoolers located a target line drawing. Method: Fifteen children over the age of 4 years (from 4;2 [years;months] to 5;4) and 15 children under the age…

  18. Fc gamma receptor activation induces the tyrosine phosphorylation of both phospholipase C (PLC)-gamma 1 and PLC-gamma 2 in natural killer cells

    1992-01-01

    Crosslinking of the low affinity immunoglobulin G (IgG) Fc receptor (Fc gamma R type III) on natural killer (NK) cells initiates antibody- dependent cellular cytotoxicity. During this process, Fc gamma R stimulation results in the rapid activation of phospholipase C (PLC), which hydrolyzes membrane phosphoinositides, generating inositol-1,4,5- trisphosphate and sn-1,2-diacylglycerol as second messengers. We have recently reported that PLC activation after Fc gamma R stimulation can be inhibit...

  19. Performance analysis of OFDM modulation on indoor broadband PLC channels

    Antonio Cortés, José; Díez, Luis; Cañete, Francisco Javier; Sánchez-Martínez, Juan José; Entrambasaguas, José Tomás

    2011-12-01

    Indoor broadband power-line communications is a suitable technology for home networking applications. In this context, orthogonal frequency-division multiplexing (OFDM) is the most widespread modulation technique. It has recently been adopted by the ITU-T Recommendation G.9960 and is also used by most of the commercial systems, whose number of carriers has gone from about 100 to a few thousands in less than a decade. However, indoor power-line channels are frequency-selective and exhibit periodic time variations. Hence, increasing the number of carriers does not always improves the performance, since it reduces the distortion because of the frequency selectivity, but increases the one caused by the channel time variation. In addition, the long impulse response of power-line channels obliges to use an insufficient cyclic prefix. Increasing its value reduces the distortion, but also the symbol rate. Therefore, there are optimum values for both modulation parameters. This article evaluates the performance of an OFDM system as a function of the number of carriers and the cyclic prefix length, determining their most appropriate values for the indoor power-line scenario. This task must be accomplished by means of time-consuming simulations employing a linear time-varying filtering, since no consensus on a tractable statistical channel model has been reached yet. However, this study presents a simpler procedure in which the distortion because of the frequency selectivity is computed using a time-invariant channel response, and an analytical expression is derived for the one caused by the channel time variation.

  20. Scientific Strategies and practices in Latin American Scientific Communication Reviews. An approach to their structural features

    Dr. Gustavo A. León Duarte

    2007-01-01

    Full Text Available The scientific production of the magazines here analyzed emphasizes the existence of a specializing and dominant perspective of study in the field of the Latin-American research in communication in the last years. This perspective of study has clearly two trends of practical boarding. A trend is the one that is debated in the research applied to the communication in means, where there exists the predominance of two particular lines of study and today probably turned into both principal slopes of study inside the Latin-American research of the communication. On the other hand, there is emphasized the research of the properly academic communication, where, in general lines, his idea of construction it develops from a particular perspective of study of the communication that no doubt is analogous to what they raise and demand separately and with different shades two of the principal institutional initiatives and collective academic that generate nowadays the Latin-American Thought of the Communication (PLC: The called Latin-American School of the Communication (ELACOM and the Researcher Latin-American Association of the Communication (ALAIC.

  1. Study of Unwanted Emissions in the CENELEC-A Band Generated by Distributed Energy Resources and Their Influence over Narrow Band Power Line Communications

    Noelia Uribe-Pérez

    2016-11-01

    Full Text Available Distributed Energy Resources might have a severe influence on Power Line Communications, as they can generate interfering signals and high frequency emissions or supraharmonics that may cause loss of metering and control data. In this paper, the influence of various energy resources on Narrowband Power Line Communications is described and analyzed through several test measurements performed in a real microgrid. Accordingly, the paper describes the effects on smart metering communications through the Medium Access Control (MAC layer analysis. Results show that the switching frequency of inverters and the presence of battery chargers are remarkable sources of disturbance in low voltage distribution networks. In this sense, the results presented can contribute to efforts towards standardization and normative of emissions at higher frequencies higher, such as CENELEC EN 50160 and IEC/TS 62749.

  2. Silica-based PLC with heterogeneously-integrated PDs for one-chip DP-QPSK receiver.

    Kurata, Yu; Nasu, Yusuke; Tamura, Munehisa; Kasahara, Ryoichi; Aozasa, Shinichi; Mizuno, Takayuki; Yokoyama, Haruki; Tsunashima, Satoshi; Muramoto, Yoshifumi

    2012-12-10

    To realize a DP-QPSK receiver PLC, we heterogeneously integrated eight high-speed PDs on a silica-based PLC platform with a PBS, 90-degree optical hybrids and a VOA. The use of a 2.5%-Δ waveguide reduced the receiver PLC size to 11 mm x 11 mm. We successfully demonstrated 32 Gbaud DP-QPSK signal demodulation with the receiver PLC.

  3. Multiuser Communication Through Power Talk in DC MicroGrids

    Angjelichinoski, Marko; Stefanovic, Cedomir; Popovski, Petar

    2016-01-01

    Power talk is a novel ultra narrow-band powerline communication (UNB-PLC) technique for communication among control units in MicroGrids (MGs). Unlike the existing UNB-PLC solutions, power talk does not require installation of additional dedicated communication hardware and, instead, uses only...... transmits at a time, and full duplex, where all units transmit and receive simultaneously. We apply the concepts of signaling space, where the power talk symbol constellations are constructed, and detection space, where the demodulation of the symbols is performed. The proposed communication technique...

  4. Synchronization in a PLC/VAX-based control and data-acquisition system of a nuclear-fusion experiment

    Schmidt, V.; Flor, G.; Hemming, O.N.; Luchetta, A.; Manduchi, G.; Vitturi, S.

    1990-01-01

    This paper describes the concept and implementation details of the synchronization mechanisms used in the control and data-acquisition system of the RFX (Reversed-Field Experiment) nuclear-fusion experimental device, at present under construction in Padova, Italy, within the framework of the co-ordinated nuclear-fusion research programme of the European Communities. The system employs industrial PLCs for the 'slow' control and monitoring functions, and a VAX-based CAMAC for the 'fast' functions of trigger-signal generation and data acquisition during the experiment pulses. All subsystems communicate via Ethernet, using compatible software protocols. The operational sequence of the complete system is governed by a single state machine implemented on a PLC-based supervisor system. Equivalent 'slave' state machines are implemented on all other subsystems (PLC- and VAX-based). These state machines are synchronized by means of the exchange of messages via Ethernet. This paper deals in detail with the following components which are involved in system synchronization: The Message Exchange System which implements the system-wide exchange of short messages; the Scheduler programs which implement the state machine on the various computing nodes, and which make use of the Message Exchange System. (orig.)

  5. COMMUNICATIONS

    L. Taylor and D. Barney

    2010-01-01

    CMS Centres, Outreach and the 7 TeV Media Event The new CMS Communications group is now established and is addressing three areas that are critical to CMS as it enters the physics operations phase: - Communications Infrastructure, including almost 50 CMS Centres Worldwide, videoconferencing systems, and CERN meeting rooms - Information systems, including the internal and external Web sites as well as the document preparation and management systems - Outreach and Education activities, including working with print, radio and TV media, visits to CMS, and exhibitions. The group has been active in many areas, with the highest priority being accorded to needs of CMS operations and preparations for the major media event planned for 7 TeV collisions. Unfortunately the CMS Centre@CERN suffered a major setback when, on 21st December, a cooling water pipe froze and burst on the floor above the CMS Centre main room. Water poured through the ceiling, flooding the floor and soaking some of the consoles, before e...

  6. COMMUNICATIONS

    A. Petrilli

    2013-01-01

    The organisation of the Open Days at the end of September was the single biggest effort of the CMS Communications Group this year. We would like to thank all volunteers for their hard work to show our Point 5 facilities and explain science and technology to the general public. During two days more than 5,000 people visited the CMS detector underground and profited from the surface activities, which included an exhibition on CMS, a workshop on superconductivity, and an activity for our younger visitors involving wooden Kapla blocks. The Communications Group took advantage of the preparations to produce new CMS posters that can be reused at other venues. Event display images have been produced not just for this occasion but also for other exhibits, education purposes, publications etc. During the Open Days, Gilles Jobin, 2012 winner of CERN Collide@CERN prize, performed his Quantum show in Point 5, with the light installation of German artist Julius von Bismarck. Image 3: CERN Open Days at CMS wel...

  7. British Nuclear Fuels PLC: report and accounts 1989-90

    1991-01-01

    Members of the Energy Select Committee put questions to representatives of British Nuclear Fuels PLC (BNFL) about the annual report and accounts 1989-90. Questions concerned the late publication of the accounts, BNFLs role in the downfall of the nuclear privatisation, government assistance to the nuclear industry, the price BNFL charges for fuel reprocessing and the process of laser isotope separation of uranium. The committee also asked about the rate of return in BNFL's assets as a percentage, Sellafield's potential as a site for a deep repository for radioactive wastes and the 6000 boreholes that MREX will drill at Sellafield. The commercial case for reprocessing is made. Feasibility studies for possible new reactions at Sellafield and Chapel Cross have been carried out. On the whole the Energy Committee were satisfied with the replies from BNFL. (UK)

  8. Formal verification of complex properties on PLC programs

    Darvas, D; Voros, A; Bartha, T; Blanco Vinuela, E; Gonzalez Suarez, V M

    2014-01-01

    Formal verification has become a recommended practice in the safety-critical application areas. However, due to the complexity of practical control and safety systems, the state space explosion often prevents the use of formal analysis. In this paper we extend our former verification methodology with effective property preserving reduction techniques. For this purpose we developed general rule-based reductions and a customized version of the Cone of Influence (COI) reduction. Using these methods, the verification of complex requirements formalised with temporal logics (e.g. CTL, LTL) can be orders of magnitude faster. We use the NuSMV model checker on a real-life PLC program from CERN to demonstrate the performance of our reduction techniques.

  9. PLC-Based Pressure Control in Multi-Pump Applications

    Vodovozov Valery

    2015-12-01

    Full Text Available The paper is devoted to the centrifugal pumps represented the most popular type of pumping equipment used in different areas. The pressure control approach for variable speed driven (VSD parallel connected centrifugal pumps is reported. The goal of the study is optimization of some quality indices, such as efficiency, consumed power, productivity, energy carrier temperature, heat irradiation, etc. One of them – efficiency – has been studied in the paper more carefully. The mathematical model of pumping process is discussed and a vector-matrix description of the multi-pump application is given. The program-based pressure control system is developed which productivity is changed by regulating the number of working pumps. The paper introduces new pressure control algorithms based on the working point estimation intended for programmable logical controllers (PLC. Experiments prove correctness of the offered methodology.

  10. “…still waiting for chloroquine”: the challenge of communicating changes in first-line treatment policy for uncomplicated malaria in a remote Kenyan district

    2014-01-01

    Background Widespread parasite resistance to first-line treatment for uncomplicated malaria leads to introduction of new drug interventions. Introducing such interventions is complex and sensitive because of stakeholder interests and public resistance. To enhance take up of such interventions, health policy communication strategies need to deliver accurate and accessible information to empower communities with necessary information and address problems of cultural acceptance of new interventions. Objectives To explore community understanding of policy changes in first-line treatment for uncomplicated malaria in Kenya; to evaluate the potential role of policy communication in influencing responses to changes in first-line treatment policy. Methods Data collection involved qualitative strategies in a remote district in the Kenyan Coast: in-depth interviews (n = 29), focus group discussions (n = 14), informal conversations (n = 11) and patient narratives (n = 8). Constant comparative method was used in the analysis. Being malaria-prone and remotely located, the district offered an ideal area to investigate whether or not and how policy communication about a matter as critical as change of treatment policy reaches vulnerable populations. Results Three years after initial implementation (2009), there was limited knowledge or understanding regarding change of first-line treatment from sulphadoxine-pyrimethamine (SP) to artemether-lumefantrine (AL) for treatment of uncomplicated malaria in the study district. The print and electronic media used to create awareness about the drug change appeared to have had little impact. Although respondents were aware of the existence of AL, the drug was known neither by name nor as the official first-line treatment. Depending on individuals or groups, AL was largely viewed negatively. The weaknesses in communication strategy surrounding the change to AL included poor choice of communication tools, confusing

  11. Normal and pathological NMR imaging aspects of the posterolateral corner (PLC) of the knee

    Tardieu, M.; Lazennec, J.Y.; Christel, P.; Brasseur, J.L.; Roger, B.; Grenier, P.

    1995-01-01

    The purpose of the study is to compare normal PLC (limits lateral condyle anterior sub luxation) anatomy and its magnetic resonance imaging (MRI) appearance, with the various lesions observed in MRI, from the simple popliteus tendinous contusion to the complete PLC rupture. For this specific work on PLC lesions, we selected 61 examinations among the traumatic knees explored during the last 3 years. Surgical correlation is obtained for the 61 patients. MRI examinations are performed on a 0.5 T. unit. Normal PLC anatomy is compared to the dissection of 4 anatomic subjects. Normal MRI slices are evaluated with this reference analysis. The principle anatomical structures of the PLC include the lateral collateral ligament, the popliteus tendon, the arcuate ligament, the fabello fibular ligament, the posterolateral condylar capsule, and the posterior horn of the lateral meniscus. Surgical findings confirm PLC lesion for 58 patients with 3 false positive. Diagnosis of these lesions is important because chronical posterolateral laxity is secondary to the destabilization of lateral condyle. Unrecognized and untreated posterolateral instability may result in failure of ACL (limits lateral condyle posterior sub-luxation) reconstruction. When clinical tests are doubtful or complex, or the examination very painful, MRI evaluates completely the traumatic knee and particularly the PLC. (authors). 3 refs., 26 figs

  12. Picture-book reading as an intervention to teach the use of line drawings for communication with students with severe intellectual disabilities.

    Stephenson, Jennifer

    2009-01-01

    Picture-book reading provides an effective intervention context for young children learning spoken language and may also be appropriate for teaching the use of augmentative and alternative communication to children with severe intellectual disabilities. This study reports on a group intervention using a semiscripted book reading routine implemented by a teacher in a classroom for students with severe intellectual disabilities. Student use of line drawings was observed over the course of the intervention. Students' abilities to match words, line drawings, book illustrations, and real objects were assessed weekly. There were differences between baseline and intervention performances for all students, and these differences were particularly noticeable for one student.

  13. Application of PLC timing control in the neutral beam injector of HT-7

    Song Shihua; Liu Zhimin; Liu Sheng; Hu Chundong

    2006-01-01

    HT-7 tokamak high power Neutral Beam Injector heating system runs in the mode of pulse timing-control of PLC. The thesis discusses the theory about the operation for the experiment of discharge, which is controlled by PLC logical connection and introduces excellent user-friendly operating interface and the development of the ladder application program and upper monitor program in the VB6.0 environment. Monitor the conditions of power and facility real time by the upper monitor interface. The application of PLC control system ensures the experiment facility running safely and convenient for modifying and setting the parameter simply during the course of experiment. (authors)

  14. Adaptation of Powerline Communications-Based Smart Metering Deployments to the Requirements of Smart Grids

    Alberto Sendin

    2015-11-01

    Full Text Available Powerline communications (PLC-based smart meter deployments are now a reality in many regions of the world. Although PLC elements are generally incorporated in smart meters and data concentrators, the underlying PLC network allows the integration of other smart grid services directly over it. The remote control capabilities that automation programs need and are today deployed over their medium voltage (MV grid, can be extended to the low voltage (LV grid through these existing PLC networks. This paper demonstrates the capabilities of narrowband high data rate (NB HDR PLC technologies deployed over LV grids for smart metering purposes to support internet protocol internet protocol (IP communications in the LV grid. The paper demonstrates these possibilities with the presentation of the simulation and laboratory results of IP communications over international telecommunication union: ITU-T G.9904 PLC technology, and the definition of a PLC Network Management System based on a simple network management protocol (SNMP management information base (MIB definition and applicable use cases.

  15. Research of home energy management system based on technology of PLC and ZigBee

    Wei, Qi; Shen, Jiaojiao

    2015-12-01

    In view of the problem of saving effectively energy and energy management in home, this paper designs a home energy intelligent control system based on power line carrier communication and wireless ZigBee sensor networks. The system is based on ARM controller, power line carrier communication and wireless ZigBee sensor network as the terminal communication mode, and realizes the centralized and intelligent control of home appliances. Through the combination of these two technologies, the advantages of the two technologies complement each other, and provide a feasible plan for the construction of energy-efficient, intelligent home energy management system.

  16. Coordination of motor systems of the control bars of TRIGA Mark III reactor, through the use of a PLC; Coordinacion de los sistemas motrices de las barras de control del reactor Triga Mark III, mediante el uso de un PLC

    Castro R, P. R.

    2016-07-01

    The use of programmable logic controllers (PLCs) has a wide field in the realization of automatic systems, since is sought that the form of control is easy for any user. In this work, the TRIGA Mark III reactor of Instituto Nacional de Investigaciones Nucleares (ININ) is intended to operate with a programming code in PLC for the automation of the control rods, having uniform wear according to the power required by the user. On the other hand, is proposed to develop an HMI graphical interface for communication via Ethernet, allowing supervision during the reactor operation process and greater protection of operators during reactor startup. The accuracy of the new actuators, as well as their durability, will allow a good performance of the reactor for many years to come. (Author)

  17. Efficient high speed communications over electrical powerlines for a large number of users

    Lee, J.; Tripathi, K.; Latchman, H.A. [Florida Univ., Gainesville, FL (United States). Dept. of Electrical and Computer Engineering

    2007-07-01

    Affordable broadband Internet communication is currently available for residential use via cable modem and other forms of digital subscriber lines (DSL). Powerline communication (PLC) systems were never considered seriously for communications due to their low speed and high development cost. However, due to technological advances PLCs are now spreading to local area networks and broadband over power line systems. This paper presented a newly proposed modification to the standard HomePlug 1.0 MAC protocol to make it a constant contention window-based scheme. The HomePlug 1.0 was developed based on orthogonal frequency division multiplexing (OFDM) and carrier sense multiple access with collision avoidance (CSMA/CA). It is currently the most commonly used technology of power line communications, supporting a transmission rate of up to 14 Mbps on the power line. However, the throughput performance of this original scheme becomes critical when the number of users increases. For that reason, a constant contention window based medium access control protocol algorithm of HomePlug 1.0 was proposed under the assumption that the number of active stations is known. An analytical framework based on Markov Chains was developed in order to model this modified protocol under saturation conditions. Modeling results accurately matched the actual performance of the system. This paper revealed that the performance can be improved significantly if the variables were parameterized in terms of the number of active stations. 15 refs., 1 tab., 6 figs.

  18. Coordination of motor systems of the control bars of TRIGA Mark III reactor, through the use of a PLC

    Castro R, P. R.

    2016-01-01

    The use of programmable logic controllers (PLCs) has a wide field in the realization of automatic systems, since is sought that the form of control is easy for any user. In this work, the TRIGA Mark III reactor of Instituto Nacional de Investigaciones Nucleares (ININ) is intended to operate with a programming code in PLC for the automation of the control rods, having uniform wear according to the power required by the user. On the other hand, is proposed to develop an HMI graphical interface for communication via Ethernet, allowing supervision during the reactor operation process and greater protection of operators during reactor startup. The accuracy of the new actuators, as well as their durability, will allow a good performance of the reactor for many years to come. (Author)

  19. PLAT: An Automated Fault and Behavioural Anomaly Detection Tool for PLC Controlled Manufacturing Systems

    Arup Ghosh

    2016-01-01

    Full Text Available Operational faults and behavioural anomalies associated with PLC control processes take place often in a manufacturing system. Real time identification of these operational faults and behavioural anomalies is necessary in the manufacturing industry. In this paper, we present an automated tool, called PLC Log-Data Analysis Tool (PLAT that can detect them by using log-data records of the PLC signals. PLAT automatically creates a nominal model of the PLC control process and employs a novel hash table based indexing and searching scheme to satisfy those purposes. Our experiments show that PLAT is significantly fast, provides real time identification of operational faults and behavioural anomalies, and can execute within a small memory footprint. In addition, PLAT can easily handle a large manufacturing system with a reasonable computing configuration and can be installed in parallel to the data logging system to identify operational faults and behavioural anomalies effectively.

  20. 78 FR 6206 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-01-30

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT..., RB211-Trent 977-84, RB211-Trent 977B-84 and RB211-Trent 980-84 turbofan engines. This AD requires on...

  1. 77 FR 20987 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2012-04-09

    ... Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION... the Federal Register. That AD applies to RB211-Trent 800 series turbofan engines. The last comment...

  2. The application of PLC automatic control system for resin transfer in pulsed elution

    Long Maoxiong

    2001-01-01

    An application of Programmable Logic Controller (PLC) in automatic control system for resin transfer in pulsed elution column is described. The design principle as well as hardware and software are also described in detail

  3. Modelling and Formal Verification of Timing Aspects in Large PLC Programs

    Fernandez Adiego, B; Blanco Vinuela, E; Tournier, J-C; Gonzalez Suarez, V M; Blech, J O

    2014-01-01

    One of the main obstacle that prevents model checking from being widely used in industrial control systems is the complexity of building formal models out of PLC programs, especially when timing aspects need to be integrated. This paper brings an answer to this obstacle by proposing a methodology to model and verify timing aspects of PLC programs. Two approaches are proposed to allow the users to balance the trade-off between the complexity of the model, i.e. its number of states, and the set of specifications possible to be verified. A tool supporting the methodology which allows to produce models for different model checkers directly from PLC programs has been developed. Verification of timing aspects for real-life PLC programs are presented in this paper using NuSMV.

  4. A formal safety analysis for PLC software-based safety critical system using Z

    Koh, Jung Soo; Seong, Poong Hyun

    1997-01-01

    This paper describes a formal safety analysis technique which is demonstrated by performing empirical formal safety analysis with the case study of beamline hutch door Interlock system that is developed by using PLC (Programmable Logic Controller) systems at the Pohang Accelerator Laboratory. In order to perform formed safety analysis, we have built the Z formal specifications representation from user requirement written in ambiguous natural language and target PLC ladder logic, respectively. We have also studied the effective method to express typical PLC timer component by using specific Z formal notation which is supported by temporal history. We present a formal proof technique specifying and verifying that the hazardous states are not introduced into ladder logic in the PLC-based safety critical system

  5. PLAT: An Automated Fault and Behavioural Anomaly Detection Tool for PLC Controlled Manufacturing Systems.

    Ghosh, Arup; Qin, Shiming; Lee, Jooyeoun; Wang, Gi-Nam

    2016-01-01

    Operational faults and behavioural anomalies associated with PLC control processes take place often in a manufacturing system. Real time identification of these operational faults and behavioural anomalies is necessary in the manufacturing industry. In this paper, we present an automated tool, called PLC Log-Data Analysis Tool (PLAT) that can detect them by using log-data records of the PLC signals. PLAT automatically creates a nominal model of the PLC control process and employs a novel hash table based indexing and searching scheme to satisfy those purposes. Our experiments show that PLAT is significantly fast, provides real time identification of operational faults and behavioural anomalies, and can execute within a small memory footprint. In addition, PLAT can easily handle a large manufacturing system with a reasonable computing configuration and can be installed in parallel to the data logging system to identify operational faults and behavioural anomalies effectively.

  6. Electromagnetic compatibility of PLC adapters for in-home/domestic networks

    Potisk, Lukas; Hallon, Jozef; Orgon, Milos; Fujdiak, Radek

    2018-01-01

    The use of programable logic controllers (PLC) technology in electrical networks 230 V causes electromagnetic radiation that interferes with other electrical equipment connected to the network [1-4]. Therefore, this article describes the issues of electromagnetic compatibility (EMC) of new PLC adapters used in IP broadband services in a multi-user environment. The measurements of disturbing electromagnetic field originated in PLC adapters were made in a certified laboratory EMC (laboratory of electromagnetic compatibility) in the Institute of Electrical Engineering at Faculty of Electrical Engineering and Information Technology of the Slovak University of Technology in Bratislava. The measured spectra of the radiated electromagnetic field will be compared with the results obtained when testing older PLC modems [5].

  7. Design of EAST LHCD high power supply feedback control system based on PLC

    Hu Huaichuan; Shan Jiafang

    2009-01-01

    Design of EAST LHCD -35kV/5.6MW high power supply feedback control system based on PLC is described. Industrial computer and PLC are used to control high power supply in the system. PID arithmetic is adopted to achieve the feedback control of voltage of high power supply. Operating system is base on real-time operating system of QNX. Good controlling properties and reliable protective properties of the feedback control system are proved by the experiment results. (authors)

  8. 77 FR 75831 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2012-12-26

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... certain serial numbers (S/Ns) of Rolls-Royce plc (RR) RB211-Trent 768-60, 772- 60, and 772B-60 turbofan... use any of the RB211-Trent 768-60, 772-60, and 772B-60 turbofan engines listed by S/N in this AD...

  9. Operating experiences with programmable logic controller (PLC) system of Indian Pressurised Heavy Water Reactors (PHWR)

    Ughade, A.V.; Singh, Ranjeet; Bhattacharya, P.K.; Kulkarni, R.K.; Chandra, Umesh

    2005-01-01

    PLC system was introduced for the first time in Kaiga-1,2 and RAPS-3,4 Nuclear Power Plants (NPPs) for Station Logic Control of Non Safety Related (NSR) and Safety related (SR) systems. However, the safety system logics are still relay based. The experience on the deployment of PLC system, which is computer-based, has brought out various implementation issues. This paper give details of such experiences, the solutions emerged and applied for plants under operation/construction. (author)

  10. What's my line? A narrative review and synthesis of the literature on Registered Nurses' communication behaviours between shifts.

    Kitson, Alison L; Muntlin Athlin, Åsa; Elliott, Janice; Cant, Megan L

    2014-06-01

    To describe, appraise and synthesize the seminal and empirical literature around Registered Nurses' communication behaviours between shifts in acute hospital settings. Effective communication between shifts (at nursing handover) is acknowledged as a prerequisite to safe and high-quality patient-centred care. However, gaps and inconsistencies continue to prevail. Narrative review and synthesis. The electronic databases PubMED, CINAHL and Scopus were used. English language, peer-reviewed papers published between 1970-April 2012 were considered for review. Criteria included Registered Nurses' communication during handovers in adult hospital settings. Twenty-nine papers were reviewed. The research lacks a clear conceptual framework to define the core purposes of Nurses' communication behaviours between shifts. Seven themes were identified: overall purpose; report givers and receivers; seeing the whole picture; teaching and education; language; patient-centred care; and social cohesion. Two main communication processes are required - one articulating the whole picture and the other detailing information about patients. This area of research is challenged by lack of consistency in terminology and methodological rigour. While recent research has confirmed the findings from the seminal work, it has not been able to elaborate on some of the key challenges to refine the knowledge base. A more integrated approach is required to understand the complex process of improving nursing communication behaviours, particularly around the nursing handover. A neglected area of study is the role of the unit lead in determining the communication standards of the whole nursing team. © 2013 John Wiley & Sons Ltd.

  11. Safety control system and its interface to EPICS for the off-line front end of the SPES project

    Vasquez, J.; Andrighetto, A.; Bassato, G.; Costa, L.; Giacchini, M.; Bertocco, M.

    2012-01-01

    The SPES (Selective Production of Exotic Species) project is based on a facility for the production of neutron-rich radioactive ion beams using the isotope separation on-line technique. The SPES off-line front-end apparatus involves a number of subsystems and procedures that are potentially dangerous both for human operators and for the equipment. The high voltage power supply, the ion source complex power supplies, the target chamber handling systems and the laser source are some example of these subsystems. For that reason, a safety control system has been developed. It is based on Schneider Electrics Preventa family safety modules that control the power supply of critical subsystems in combination with safety detectors that monitor critical variables. A Programmable Logic Controller (PLC), model BMXP342020 from the Schneider Electrics Modicon M340 family, is used for monitoring the status of the system as well as controlling the sequence of some operations in automatic way. A touch screen, model XBTGT5330 from the Schneider Electrics Magelis family, is used as Human Machine Interface (HMI) and communicates with the PLC using MODBUS-TCP. Additionally, an interface to the EPICS control network was developed using a home-made MODBUS-TCP EPICS driver in order to integrate it to the control system of the Front End as well as present the status of the system to the users on the main control panel. (authors)

  12. The YvfTU Two-component System is involved in plcR expression in Bacillus cereus

    Nguyen-the Christophe

    2008-10-01

    Full Text Available Abstract Background Most extracellular virulence factors produced by Bacillus cereus are regulated by the pleiotropic transcriptional activator PlcR. Among strains belonging to the B. cereus group, the plcR gene is always located in the vicinity of genes encoding the YvfTU two-component system. The putative role of YvfTU in the expression of the PlcR regulon was therefore investigated. Results Expression of the plcR gene was monitored using a transcriptional fusion with a lacZ reporter gene in a yvfTU mutant and in its B. cereus ATCC 14579 parental strain. Two hours after the onset of the stationary phase, a stage at which the PlcR regulon is highly expressed, the plcR expression in the yvfTU mutant was only 50% of that of its parental strain. In addition to the reduced plcR expression in the yvfTU mutant, a few members of the PlcR regulon showed a differential expression, as revealed by transcriptomic and proteomic analyses. The virulence of the yvfTU mutant in a Galleria mellonella insect model was slightly lower than that of the parental strain. Conclusion The YvfTU two-component system is not required for the expression of most of the virulence factors belonging to the PlcR regulon. However, YvfTU is involved in expression of plcR, a major regulator of virulence in B. cereus.

  13. Development of Multipurpose PLC trainer for the simulator of reactor safety system

    Syaiful Bakhri; Deswandri; Ahmad Abtokhi

    2014-01-01

    PLC becomes one of the essential components for the current type of reactor which based on digital instrumentation and control. Several studies have demonstrated the promising results including the implementation of PLC's for RSG-GAS research reactor. However, research for the safety and reliability analysis can not be carried out freely in the existing systems.Therefore, this research aims to develop a PLC trainer employing micro PLC OMRON CP1MA which can be useful for simulator of various topics in reactor safety. Two experimental tests were carried out to show the PLC’s performances. The first experimental testing implementing reactor protection system of research reactor RSG-GAS shows the capacity of PLC system to identify the initiator of the SCRAM logic as well as giving a promptly response. Secondly, the application of PLC to controls the water level in dual reservoir system simulation, demonstrates the simplicity of the operation and design while maintaining the best performances. (author)

  14. A formal safety analysis for PLC software-based safety critical system using Z

    Koh, Jung Soo

    1997-02-01

    This paper describes a formal safety analysis technique which is demonstrated by performing empirical formal safety analysis with the case study of beamline hutch door Interlock system that is developed by using PLC (Programmable Logic Controller) systems at the Pohang Accelerator Laboratory. In order to perform formal safety analysis, we have built the Z formal specifications representation from user requirement written in ambiguous natural language and target PLC ladder logic, respectively. We have also studied the effective method to express typical PLC timer component by using specific Z formal notation which is supported by temporal history. We present a formal proof technique specifying and verifying that the hazardous states are not introduced into ladder logic in the PLC-based safety critical system. And also, we have found that some errors or mismatches in user requirement and final implemented PLC ladder logic while analyzing the process of the consistency and completeness of Z translated formal specifications. In the case of relatively small systems like Beamline hutch door interlock system, a formal safety analysis including explicit proof is highly recommended so that the safety of PLC-based critical system may be enhanced and guaranteed. It also provides a helpful benefits enough to comprehend user requirement expressed by ambiguous natural language

  15. Optical interconnection for a polymeric PLC device using simple positional alignment.

    Ryu, Jin Hwa; Kim, Po Jin; Cho, Cheon Soo; Lee, El-Hang; Kim, Chang-Seok; Jeong, Myung Yung

    2011-04-25

    This study proposes a simple cost-effective method of optical interconnection between a planar lightwave circuit (PLC) device chip and an optical fiber. It was conducted to minimize and overcome the coupling loss caused by lateral offset which is due to the process tolerance and the dimensional limitation existing between PLC device chips and fiber array blocks with groove structures. A PLC device chip and a fiber array block were simultaneously fabricated in a series of polymer replication processes using the original master. The dimensions (i.e., width and thickness) of the under-clad of the PLC device chip were identical to those of the fiber array block. The PLC device chip and optical fiber were aligned by simple positional control for the vertical direction of the PLC device chip under a particular condition. The insertion loss of the proposed 1 x 2 multimode optical splitter device interconnection was 4.0 dB at 850 nm and the coupling loss was below 0.1 dB compared with single-fiber based active alignment.

  16. Arbitration Award of ICSID on the Investment Disputes of Churchill Mining PLC v. Republic of Indonesia

    Yordan Gunawan

    2017-03-01

    Full Text Available The research is aimed at analyzing the ICSID (International Centre Settlement Investment Dispute decision in solving a dispute between Churchill Mining PLC and the Government of the Republic of Indonesia. The case brought to the public attention, because mining license owned by PT. Ridlatama which acquired from Churchill Mining PLC had been revocated. Churchill Mining PLC holds 75% share of PT. Ridlatama and it suffered losses caused by the revocation of its mining license. Churchill Mining PLC filed the case to the local court but it failed. Churchill Mining PLC then sought ruling from International arbitration or ICSID. On December 6, 2016, ICSID issued a decision that clearly threw out Churchill Mining PLC claim. ICSID, the World Bank court, ordered the firm to pay a total of US$.9.446.528 in cost to the Government of the Republic of Indonesia. It is based on the evidences that the UK-Australia company did the fraud and had document forgery of coal mining permit in East Kutai, Indonesia. So the firm has violated the Bilateral Investment Treaties between Indonesia-UK and Indonesia-Australia.

  17. In-Containment Signal Acquisition and Data Transmission via Power Lines within High Dose Areas of Nuclear Power Plants

    Mueller Steffen; Wibbing Sascha; Weigel Robert; Koelpin Alexander; Dennerlein, Juergen; Janke, Iryna; Weber, Johannes

    2015-01-01

    Signal acquisition and data transmission for innovative sensor systems and networks inside the containment of nuclear power plants (NPPs) is still a challenge with respect to safety, performance, reliability, availability, and costs. This especially applies to equipment upgrades for existing plants, special measurements, but also for new builds. This paper presents a novel method for efficient and cost-effective sensor signal acquisition and data transmission via power lines, in order to cope with the disadvantages of common system architectures that often suffer from poor signal integrity due to raw data transmissions via long cables, huge efforts and costs for installation, and low flexibility with respect to maintenance and upgrades. A transmitter-receiver architecture is proposed that allows multiplexing of multiple sensor inputs for unidirectional point-to-point transmission by superimposing information signals on existing AC or DC supply lines, but also on active and inactive sensor wires, or spare cables, using power line communication (PLC) technology. Based on commercial off-the-shelf (COTS) electronic parts, a radiation hard transmitter hardware is designed to operate in harsh environment within the containment during full plant operation. The system's modular approach allows application specific trade-offs between redundancy and throughput regarding data transmission, as well as various sensor input front-ends which are compatible with state of the art systems. PLC technology eliminates the need for costly installation of additional cables and wall penetrations, while providing a complementary and diverse communication technology for upgrades of existing systems. At the receiver side in low dose areas, signals are extracted from the power line, demodulated, and de-multiplexed, in order to regain the original sensor signal information and provide it either in analog or digital output format. Successful laboratory qualification tests, field trails

  18. In-Containment Signal Acquisition and Data Transmission via Power Lines within High Dose Areas of Nuclear Power Plants

    Mueller Steffen; Wibbing Sascha; Weigel Robert; Koelpin Alexander [Institute for Electronics Engineering, University of Erlangen-Nuremberg (Germany); Dennerlein, Juergen; Janke, Iryna; Weber, Johannes [AREVA GmbH, Paul-Gossen-Str. 100, 91052 Erlangen (Germany)

    2015-07-01

    Signal acquisition and data transmission for innovative sensor systems and networks inside the containment of nuclear power plants (NPPs) is still a challenge with respect to safety, performance, reliability, availability, and costs. This especially applies to equipment upgrades for existing plants, special measurements, but also for new builds. This paper presents a novel method for efficient and cost-effective sensor signal acquisition and data transmission via power lines, in order to cope with the disadvantages of common system architectures that often suffer from poor signal integrity due to raw data transmissions via long cables, huge efforts and costs for installation, and low flexibility with respect to maintenance and upgrades. A transmitter-receiver architecture is proposed that allows multiplexing of multiple sensor inputs for unidirectional point-to-point transmission by superimposing information signals on existing AC or DC supply lines, but also on active and inactive sensor wires, or spare cables, using power line communication (PLC) technology. Based on commercial off-the-shelf (COTS) electronic parts, a radiation hard transmitter hardware is designed to operate in harsh environment within the containment during full plant operation. The system's modular approach allows application specific trade-offs between redundancy and throughput regarding data transmission, as well as various sensor input front-ends which are compatible with state of the art systems. PLC technology eliminates the need for costly installation of additional cables and wall penetrations, while providing a complementary and diverse communication technology for upgrades of existing systems. At the receiver side in low dose areas, signals are extracted from the power line, demodulated, and de-multiplexed, in order to regain the original sensor signal information and provide it either in analog or digital output format. Successful laboratory qualification tests, field trails

  19. The effects of color cues on typically developing preschoolers' speed of locating a target line drawing: implications for augmentative and alternative communication display design.

    Thistle, Jennifer J; Wilkinson, Krista

    2009-08-01

    This research examined how the presence of color in relation to a target within an augmentative and alternative communication array influenced the speed with which typically developing preschoolers located a target line drawing. Fifteen children over the age of 4 years (from 4;2 [years;months] to 5;4) and 15 children under the age of 4 years (2;10-3;11) participated. Participants were asked to find a target line drawing of foods (e.g., banana and tomato) among an array of 12. The reaction time of locating the target was measured across 4 conditions in which the foreground color and the background color of the line drawing were manipulated. For all participants, line drawings featuring foreground color provided greater advantages in the speed of locating the target compared with drawings featuring only background color. Younger participants demonstrated faster reaction times when color was limited to the foreground. Clinicians should consider incorporating color in the foreground of the line drawing when constructing visual displays. Targets that contain only background color but no foreground color appear to have a negative effect on the speed with which younger children can locate a target. Further research is needed to determine the effects in children with disabilities.

  20. Modeling MAC layer for powerline communications networks

    Hrasnica, Halid; Haidine, Abdelfatteh

    2001-02-01

    The usage of electrical power distribution networks for voice and data transmission, called Powerline Communications, becomes nowadays more and more attractive, particularly in the telecommunication access area. The most important reasons for that are the deregulation of the telecommunication market and a fact that the access networks are still property of former monopolistic companies. In this work, first we analyze a PLC network and system structure as well as a disturbance scenario in powerline networks. After that, we define a logical structure of the powerline MAC layer and propose the reservation MAC protocols for the usage in the PLC network which provides collision free data transmission. This makes possible better network utilization and realization of QoS guarantees which can make PLC networks competitive to other access technologies.

  1. Turn on the lights: leveraging visible light for communications and positioning

    Hranilovic, Steve

    2015-01-01

    The need for ubiquitous broadband connectivity is continually growing, however, radio spectrum is increasingly scarce and limited by interference. In addition, the energy efficiency of many radio transmitters is low and most input energy is converted to heat. A widely overlooked resource for positioning and broadband access is optical wireless communication reusing existing illumination installations. As many of the 14 billion incandescent bulbs in use worldwide are converted to energy efficient LED lighting, a unique opportunity exists to augment them with visible light communications (VLC) and visible light positioning (VLP). VLC- and VLP- enabled LED lighting is not only energy efficient but enables a host of new use cases such as location-aware ubiquitous high-speed wireless communication links. This talk presents the recent work of the Free-space Optical Communication Algorithms Laboratory (FOCAL) at McMaster University in Hamilton, Canada in developing novel signaling and indoor localization techniques using illumination devices. Developments in the signaling design for VLC systems will be presented along with several prototype VLC communication systems. Novel approaches to the integration of VLC networks with power line communications (PLC) are discussed. The role of visible light communications and ranging for automotive safety will also be highlighted. Several approaches to indoor positioning using illumination devices and simple smartphone-based receivers will be presented. Finally, a vision for VLC and VLP technologies will be presented along with our ongoing research directions.

  2. Are managers' and the general public's perceptions of risk communication needs in line? A French alpine valley case study

    Charrière, Marie; Sprague, Teresa; Bogaard, Thom; Greiving, Stefan; Malet, Jean-Philippe; Mostert, Erik

    2013-04-01

    Risk communication is a crucial element of risk management. It contributes to social capacity building by influencing the knowledge, attitude, behavior, psychology, as well as social and organizational aspects1,2. It is globally recognized that effective risk communication should address needs and requirements of targeted audiences, especially those of the public. This study compares needs and requirements related to risk communication as seen by the risk managers, with the needs and requirements as expressed by the general public. Two surveys were conducted in a mountainous region facing multi-hazards, the Ubaye valley (France). The first survey, conducted within the context of the Marie Curie Research and Training Network 'Mountain Risk', was addressed to the local community. It aimed at gathering perceptions, needs and requirements of the general public (344 respondents) on risk communication3. The second survey, conducted in the context of the Marie Curie Initial Training Network 'CHANGES', targeted risk managers (16 stakeholders of the authorities, technical services and emergency units) at both the local and the regional scale to evaluate their perceptions regarding risk communication with the general public. The needs and requirements were analyzed with respect to several dimensions: 1) the information provided to the public, 2) the legal requirements for communication, 3) the level of trust the population has in risk managers, 4) insights on awareness and preparedness, and 5) information on the media used in past communication efforts. Results of the analysis concerning the last dimension reveal that, while the general public mentioned press, official reports and technical reports as the top three media by which they received information, the risk managers cited the press but in contrast also selected radio and television. Other results indicate that a potential mismatch exists as more than 80% of the respondents of the population find all listed topics

  3. The Design and Realization of Virtual Machine of Embedded Soft PLC Running System

    Qingzhao Zeng

    2014-11-01

    Full Text Available Currently soft PLC has been the focus of study object for many countries. Soft PLC system consists of the developing system and running system. A Virtual Machine is an important part in running system even in the whole soft PLC system. It explains and performs intermediate code generated by the developing system and updates I/O status of PLC in order to complete its control function. This paper introduced the implementation scheme and execution process of the embedded soft PLC running system Virtual Machine, and mainly introduced its software implementation method, including the realization of the input sampling program, the realization of the instruction execution program and the realization of output refresh program. Besides, an operation code matching method was put forward in the instruction execution program design. Finally, the test takes PowerPC/P1010 (Freescale as the hardware platform and Vxworks as the operating system, the system test result shows that accuracy, the real-time performance and reliability of Virtual Machine.

  4. PLC and DTAM Software Programs for Pumping Instrumentation and Control Skid N

    KOCH, M.R.

    2000-01-01

    This document describe the software programs for the Programmable Logic Controller and the Datable Access Module for Pumping Instrumentation and Control skid ''N''. The Appendices contains copies of the printouts of these software programs. This document describes the software programs for the Allen-Bradley SLC 500 programmable logic controller (PLC) and the Allen-Bradley DTAM PLUS operator interface module used on Pumping Instrumentation and Control (PIC) skid ''N''. The software programs for the SLC 500 and DTAM Plus are based on the core programs provided by Allen-Bradley. The PLC and DTAM software programs on skid ''D'' for SX-104 are the baseline programs. These baselines have been tailored for U-farm skids. The skid ''N'' program for U-109 is similar to the skid ''M'' program for U-102. An Acceptance Test Procedure (ATP) and an Operational Test Procedure (OTP) verify that the software programs meet the specific requirements for U-109 pumping. This document represents the final PLC and DTAM programs for PIC skid ''N'' at U-109. These programs were printed out after the performance of the OTP. The OTP acts as the final qualification test for the software programs. Functional requirements and details of the PLC ladder logic are described in this document. The final programs entered into the PLC and DTAM Plus are included as Appendices to this document

  5. Realizace úzkopásmových PLC modemů

    Kubíček, Lukáš

    2012-01-01

    Diplomová práce se věnuje úzkopásmové technologii přenosu dat el. sítí NN (PLC) a~možnostem jejího využití v senzorových sítích. Zabývá se jak strukturou a základními vlastnostmi PLC standardu, tak možnostmi jeho uplatnění v praxi. Hlavní částí této práce je realizace PLC sítě pomocí IO ST7570 firmy STMicroelectronics. Jako příklad praktického využití PLC technologie je tato síť připojena k počítači, ve kterém jsou data ze senzoru (wattmetru) připojenému k PLC modemu ukládána pomocí aplikace ...

  6. PLC-based mode multi/demultiplexers for mode division multiplexing

    Saitoh, Kunimasa; Hanzawa, Nobutomo; Sakamoto, Taiji; Fujisawa, Takeshi; Yamashita, Yoko; Matsui, Takashi; Tsujikawa, Kyozo; Nakajima, Kazuhide

    2017-02-01

    Recently developed PLC-based mode multi/demultiplexers (MUX/DEMUXs) for mode division multiplexing (MDM) transmission are reviewed. We firstly show the operation principle and basic characteristics of PLC-based MUX/DEMUXs with an asymmetric directional coupler (ADC). We then demonstrate the 3-mode (2LP-mode) multiplexing of the LP01, LP11a, and LP11b modes by using fabricated PLC-based mode MUX/DEMUX on one chip. In order to excite LP11b mode in the same plane, a PLC-based LP11 mode rotator is introduced. Finally, we show the PLC-based 6-mode (4LP-mode) MUX/DEMUX with a uniform height by using ADCs, LP11 mode rotators, and tapered waveguides. It is shown that the LP21a mode can be excited from the LP11b mode by using ADC, and the two nearly degenerated LP21b and LP02 modes can be (de)multiplexed separately by using tapered mode converter from E13 (E31) mode to LP21b (LP02) mode.

  7. Separation of integrin-dependent adhesion from morphological changes based on differential PLC specificities.

    Wooten, D K; Teague, T K; McIntyre, B W

    1999-01-01

    In normal lymphocytes an inside-out signal up-regulating integrin adhesion is followed by a ligand-mediated outside-in cell spreading signal. Protein kinase C (PKC) inhibition blocks lymphocyte adherence to and spreading on fibronectin. In contrast, putative PLC inhibitors yield distinct differences with respect to adhesion and morphology. The phosphatidylinositol-specific phospholipase C (PLC) inhibitor neomycin blocked spreading of CD3/CD28-activated T cells on fibronectin by disrupting adhesion. Furthermore, when an additional inside-out signal for fibronectin adhesion is unnecessary such as with HPB-ALL T leukemic or phorbol-myristate-acetate-treated normal T cells, neomycin treatment does not alter adhesion or morphology. However, the phosphatidylcholine-specific PLC inhibitor D609 abrogates cell spreading without affecting adhesion to fibronectin in these cells as well as the CD3/CD28-activated T cells. These results strongly suggest that inside-out signaling for the integrin alpha4beta1 in lymphocytes proceeds through phosphatidylinositol-specific PLC and PKC, whereas the outside-in signal utilizes phosphatidylcholine-specific PLC and PKC.

  8. An Architecture Of Plc Ls Xbc-Dr30e Based Clean Water Controlling System

    M.Jusuf Jamanawar Purba

    2017-12-01

    Full Text Available In the industrial field the good controlling system is definitely required to improve the working efficiency of a system. The type of controller PLC Programmable Logic Controller used in Clean Water Controlling System in Electrical Workshop with PLC LS XBC-DR30E. Furthermore such system consistently uses two types of component they are Relay and Timer. The clean water pump control aims to pump the water in well A to storage tank B. The pump will work when water-contained well A is marked by sensor level well A on and the water inside storage tank B is under level 3. When the water inside storage tank B is under level 2 both pumps M1 and M2 will work to fill storage tank B. on the contrary when storage tank B is above level 2 only one pump M1 works until the tank reach level 3. In addition when storage tank B is above level 3 both pumps will stop working. However along with the advancement of recent technology the above system can be controlled by using PLC Programmable Logic Controller. Therefore it is possible to apply the controlling method of PLC as the semester Vs practical module. Based on the trial performed the PLC-based clean water system is well-functioned as the working description compiled before the operation of the tool.

  9. PLC/DTAM Software Programs for Pumping Instrumentation and Control Skid X

    HORNER, T.M.

    2001-01-01

    This document describes the software programs for the Allen-Bradley SLC 500 programmable logic controller (PLC) and the Allen-Bradley DTAM PLUS operator interface module used on Pumping Instrumentation and Control (PIC) skid ''X''. The software programs for the SLC 500 and DTAM Plus are based on the core programs provided by Allen-Bradley. The PLC and DTAM software programs on skid ''D'' for SX-104 are the baseline programs. These baselines will be tailored for each individual BY-farm skid. An Acceptance Test Procedure (ATP) and an Operational Test Procedure (OTP) verify that the software programs meet the specific requirements for BY-105 pumping. This document represents the final PLC and DTAM programs for PIC skid ''X'' at BY-105. These programs were printed out after the performance of the OTP. The OTP acts as the final qualification test for the software programs. Functional requirements and details of the PLC ladder logic are described in this document. The final programs entered into the PLC and DTAM Plus are included as Appendices to this document

  10. Intercellular odontoblast communication via ATP mediated by pannexin-1 channel and phospholipase C-coupled receptor activation.

    Masaki eSato

    2015-11-01

    Full Text Available Extracellular ATP released via pannexin-1 channels, in response to the activation of mechanosensitive-TRP channels during odontoblast mechanical stimulation, mediates intercellular communication among odontoblasts in dental pulp slice preparation dissected form rat incisor. Recently, odontoblast cell lines, such as mouse odontoblast lineage cells, have been widely used to investigate physiological/pathological cellular functions. To clarify whether the odontoblast cell lines also communicate with each other by diffusible chemical substance(s, we investigated the chemical intercellular communication among cells from mouse odontoblast cell lines following mechanical stimulation. A single cell was stimulated using a glass pipette filled with standard extracellular solution. We measured intracellular free Ca2+ concentration ([Ca2+]i by fura-2 in stimulated cells, as well as in cells located nearby. Direct mechanical stimulation to a single odontoblast increased [Ca2+]i, which showed sensitivity to capsazepine. In addition, we observed increases in [Ca2+]i not only in the mechanically stimulated odontoblast, but also in nearby odontoblasts. We could observe mechanical stimulation-induced increase in [Ca2+]i in a stimulated human embryo kidney (HEK 293 cell, but not in nearby HEK293 cells. The increase in [Ca2+]i in nearby odontoblasts, but not in the stimulated odontoblast, was inhibited by adenosine triphosphate (ATP release channel (pannexin-1 inhibitor in a concentration- and spatial-dependent manner. Moreover, in the presence of phospholipase C (PLC inhibitor, the increase in [Ca2+]i in nearby odontoblasts, following mechanical stimulation of a single odontoblast, was abolished. We could record some inward currents evoked from odontoblasts near the stimulated odontoblast, but the currents were observed in only 4.8% of the recorded odontoblasts. The results of this study showed that ATP is released via pannexin-1, from a mechanically stimulated

  11. MultiController: the PLC-SCADA object for advanced regulation

    Ortola, J

    2007-01-01

    Nowadays, industrial solutions with PLCs (Programmable Logic Controllers) have basic control loop features. The SCADA (Supervisory Control And Data Acquisition) system is a key point of the process control system due to an efficient HMI (Human Machine Interfaces) that provides an open method of tuning and leading possibilities. As a consequence, advanced control algorithms have to be developed and implemented for those PLC-SCADA solutions in order to provide perspectives in solving complex and critical regulation problems. The MultiController is an object integrated for a large scale project at CERN (the European Organization for Nuclear Research) named LHC-GCS (Large Hadron Collider - Gas Control System). It is developed for a Framework called CERN-UNICOS based on PLC-SCADA facilities. The MultiController object offers various advanced control loop strategies. It gives to the user advanced control algorithms like PID, Smith Predictor, PFC, GPC and RST. It is implemented as a monolithic entity (in PLC and SCA...

  12. Design and implementation of tutorials for PLC B&R Automation

    Sýkora, Daniel

    2014-01-01

    Tato bakalářská práce se zabývá návrhem a realizací úloh pro PLC B&R a podrobným návodem práce v Automation Studio. Obsahuje také informace o firmě B&R Automation Ges. m. b. H. a jejích produktech. Návrh úloh probíhal ve vývojovém prostředí B&R Automation Studio. Praktická úloha na regulaci teploty byla řešena a odzkoušena na B&R PLC X20. This bachelor’s thesis deals with the design and the implementation tutorials for PLC B&R as well as the detailed instructions of work in the Automation ...

  13. Reliability Analysis of Safety Grade PLC(POSAFE-Q) for Nuclear Power Plants

    Kim, J. Y.; Lyou, J.; Lee, D. Y.; Choi, J. G.; Park, W. M.

    2006-01-01

    The Part Count Method of the military standard MILHDK- 217F has been used for the reliability prediction of the nuclear field. This handbook determines the Programmable Logic Controller (PLC) failure rate by summing the failure rates of the individual component included in the PLC. Normally it is easily predictable that the components added for the fault detection improve the reliability of the PLC. But the application of this handbook is estimated with poor reliability because of the increased component number for the fault detection. To compensate this discrepancy, the quantitative reliability analysis method is suggested using the functional separation model in this paper. And it is applied to the Reactor Protection System (RPS) being developed in Korea to identify any design weak points from a safety point of view

  14. Bringing Automated Model Checking to PLC Program Development - A CERN Case Study

    Fernandez Adiego, B; Tournier, J-C; Blanco Vinuela, E; Gonzalez Suarez, V M

    2014-01-01

    Verification of critical software is a high priority but a challenging task for industrial control systems. Model checking appears to be an appropriate approach for this purpose. However, this technique is not widely used in industry yet, due to some obstacles. The main obstacles encountered when trying to apply formal verification techniques at industrial installations are the difficulty of creating models out of PLC programs and defining formally the specification requirements. In addition, models produced out of real-life programs have a huge state space, thus preventing the verification due to performance issues. Our work at CERN (European Organization for Nuclear Research) focuses on developing efficient automatic verification methods for industrial critical installations based on PLC (Programmable Logic Controller) control systems. In this paper, we present a tool generating automatically formal models out of PLC code. The tool implements a general methodology which can support several input languages, ...

  15. Design and Implementation of PLC-Based Automatic Sun tracking System for Parabolic Trough Solar Concentrator

    Wang Jinping

    2016-01-01

    Full Text Available A sun-tracking system for parabolic trough solar concentrators (PTCs is a control system used to orient the concentrator toward the sun always, so that the maximum energy can be collected. The work presented here is a design and development of PLC based sun tracking control system for PTC. Sun tracking control system consists of a Programmable Logic Controller (PLC and a single axis hydraulic drives tracking control system. Hydraulic drives and the necessary tracking angle algorithm have been designed and developed to perform the technical tasks. A PLC unit was employed to control and monitor the mechanical movement of the PTC and to collect and store data related to the tracking angle of PTC. It is found that the tracking error of the system is less than 0.6°. Field experience shows that tracking algorithm act stable and reliable and suit for PTCs.

  16. Johnson(-like)-Noise-Kirchhoff-loop based secure classical communicator characteristics, for ranges of two to two thousand kilometers, via model-line

    Mingesz, Robert; Gingl, Zoltan; Kish, Laszlo B.

    2008-01-01

    A pair of Kirchhoff-loop-Johnson(-like)-Noise communicators, which is able to work over variable ranges, was designed and built. Tests have been carried out on a model-line performance characteristics were obtained for ranges beyond the ranges of any known direct quantum communication channel and they indicate unrivalled signal fidelity and security performance of the exchanged raw key bits. This simple device has single-wire secure key generation and sharing rates of 0.1, 1, 10, and 100 bit/second for corresponding copper wire diameters/ranges of 21 mm/2000 km, 7 mm/200 km, 2.3 mm/20 km, and 0.7 mm/2 km, respectively and it performs with 0.02% raw-bit error rate (99.98% fidelity). The raw-bit security of this practical system significantly outperforms raw-bit quantum security. Current injection breaking tests show zero bit eavesdropping ability without triggering the alarm signal, therefore no multiple measurements are needed to build an error statistics to detect the eavesdropping as in quantum communication. Wire resistance based breaking tests of Bergou-Scheuer-Yariv type give an upper limit of eavesdropped raw-bit ratio of 0.19% and this limit is inversely proportional to the sixth power of cable diameter. Hao's breaking method yields zero (below measurement resolution) eavesdropping information

  17. Construction and Verification of PLC LD-programs by LTL-specification

    E. V. Kuzmin

    2013-01-01

    Full Text Available An approach to construction and verification of PLC LD-programs for discrete problems is proposed. For the specification of the program behavior, we use the linear-time temporal logic LTL. Programming is carried out in the LD-language (Ladder Diagram according to an LTL-specification. The correctness analysis of an LTL-specification is carried out by the symbolic model checking tool Cadence SMV. A new approach to programming and verification of PLC LD-programs is shown by an example. For a discrete problem, we give a LD-program, its LTL-specification and an SMV-model. The purpose of the article is to describe an approach to programming PLC, which would provide a possibility of LD-program correctness analysis by the model checking method. Under the proposed approach, the change of the value of each program variable is described by a pair of LTL-formulas. The first LTL-formula describes situations which increase the value of the corresponding variable, the second LTL-formula specifies conditions leading to a decrease of the variable value. The LTL-formulas (used for speci- fication of the corresponding variable behavior are constructive in the sense that they construct the PLC-program (LD-program, which satisfies temporal properties expressed by these formulas. Thus, the programming of PLC is reduced to the construction of LTLspecification of the behavior of each program variable. In addition, an SMV-model of a PLC LD-program is constructed according to LTL-specification. Then, the SMV-model is analysed by the symbolic model checking tool Cadence SMV.

  18. Comparison of the effect of interferon on two human hepatoma cell lines

    Crespi, M; Schoub, B D; Lyons, S F; Chiu, M N [University of the Witwatersrand, Johannesburg (South Africa). Dept. of Virology

    1985-06-01

    Two human hepatoma cell lines, the PLC/PRF/5 and the Mahlavu cells, which differ in their production of the hepatitis B surface antigen (HBsAg), responded differently to interferon (IFN). After IFN treatment both cell lines were able to inhibit Sindbis virus replication. Oligo A synthetase (E enzyme) could be activated in the PLC/PRF/5 cells although they were not sensitive to exogenous 2 - 5 oligoadenylic acid (2 - 5 A). In contrast, the Mahlavu cells were sensitive to exogenous 2 - 5 A, but unable to activate the E enzyme. Both cell lines were unable to stimulate phosphorylation of the exogenous initiator factor eIF-2.

  19. The Research about Embedded Soft PLC Running System Based on ARM

    Fang Ding

    2014-09-01

    Full Text Available The paper discusses the overall construction and operational principle of soft PLC. Considering the real time request of the system, we use Linux+RTAI dual core system as software platform. In this platform, the implementation method of soft PLC operational system is introduced. Especially, the design of instruction analysis module is emphasized. On the basis of energy flow concept, the logic algorithm is established, aligning to the left bus. Finally, the system is tested to evaluate the desired control behavior.

  20. A fast PID controller Design for Modern PLC for Process Control Application

    Mirza, A.; Nafis, A.; Anees, R.M.; Idris, S.

    2004-01-01

    PID is the most widely used control scheme in the process industry. Pill controllers are utilized for the control of such varied parameters as pressure, flow, temperature, etc. One characteristic of these parameters is that they posses slow dynamics. Most of the available digital controllers can manipulate only a single parameter- multiple controllers are required for control of more than one parameter. The Fast PID Controller for Modem PLC (Programmable Logic Controller) developed by the authors, provides control of several parameters at a time (through a single Pill control element), enhanced programmability including variable sampling period, parameter monitoring and data storage, which may be easily implemented in a PLC. (author)

  1. An Integrated Software Development Framework for PLC and FPGA based Digital I and Cs

    Yoo, Jun Beom; Kim, Eui Sub; Lee, Dong Ah; Choi, Jong Gyun

    2014-01-01

    NuDE 2.0 (Nuclear Development Environment) is a model-based software development environment for safety- critical digital systems in nuclear power plants. It makes possible to develop PLC-based systems as well as FPGA-based systems simultaneously from the same requirement or design specifications. The case study showed that the NuDE 2.0 can be adopted as an effective method of bridging the gap between the existing PLC and upcoming FPGA-based developments as well as a means of gaining diversity

  2. PLC-based LP₁₁ mode rotator for mode-division multiplexing transmission.

    Saitoh, Kunimasa; Uematsu, Takui; Hanzawa, Nobutomo; Ishizaka, Yuhei; Masumoto, Kohei; Sakamoto, Taiji; Matsui, Takashi; Tsujikawa, Kyozo; Yamamoto, Fumihiko

    2014-08-11

    A PLC-based LP11 mode rotator is proposed. The proposed mode rotator is composed of a waveguide with a trench that provides asymmetry of the waveguide. Numerical simulations show that converting LP11a (LP11b) mode to LP11b (LP11a) mode can be achieved with high conversion efficiency (more than 90%) and little polarization dependence over a wide wavelength range from 1450 nm to 1650 nm. In addition, we fabricate the proposed LP11 mode rotator using silica-based PLC. It is confirmed that the fabricated mode rotator can convert LP11a mode to LP11b mode over a wide wavelength range.

  3. An Integrated Software Development Framework for PLC and FPGA based Digital I and Cs

    Yoo, Jun Beom; Kim, Eui Sub; Lee, Dong Ah [Konkuk University, Seoul (Korea, Republic of); Choi, Jong Gyun [KAERI, Daejeon (Korea, Republic of)

    2014-08-15

    NuDE 2.0 (Nuclear Development Environment) is a model-based software development environment for safety- critical digital systems in nuclear power plants. It makes possible to develop PLC-based systems as well as FPGA-based systems simultaneously from the same requirement or design specifications. The case study showed that the NuDE 2.0 can be adopted as an effective method of bridging the gap between the existing PLC and upcoming FPGA-based developments as well as a means of gaining diversity.

  4. One-way data transfer for PLC to VME status reporting at the Advanced Photon Source

    Stein, S.J.

    1993-01-01

    The Personnel Safety System for the experimental beamlines at the Advanced Photon Source will use a large number of Allen Bradley Programmable Logic Controllers (PLC) to replace conventional relay logic. PLCs allow for the design of a very advanced safety system that can handle a large number of I/O points. Certain situations Require monitoring of the safety system from various locations around the storage ring via EPICS OPI (operator interface)consoles. This presentation covers the method of choice for transferring data from the Personnel Safety System into an EPICS database. Specifics on PLC ladder design, EPICS database design, and hardware selection are also discussed

  5. 75 FR 61361 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-535 Series Turbofan Engines

    2010-10-05

    ...-0994; Directorate Identifier 2009-NE-39-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR...-Royce plc., P.O. Box 31, Derby, DE24 8BJ, United Kingdom; Telephone: 011 44 1332 242424, Fax: 011 44... based on those comments. We will post all comments we receive, without change, to http://www.regulations...

  6. 76 FR 78805 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines

    2011-12-20

    ... Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines AGENCY: Federal Aviation... all Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines. This AD results from mandatory... inspection of the FOHE mounts. We did not change the AD based on this comment. Request To Add Requirement To...

  7. 76 FR 65997 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-535 Series Turbofan Engines

    2011-10-25

    ...-0994; Directorate Identifier 2009-NE-39-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR... Friday, except Federal holidays. For service information identified in this AD, contact Rolls-Royce plc.... Based on these figures, we estimate the cost of this proposed AD on U.S. operators to be $1,499,400. FAA...

  8. 75 FR 45560 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines

    2010-08-03

    ...-0755; Directorate Identifier 2010-NE-12-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR... based on engine thrust rating but now based on operating shaft speeds) introduced by Rolls- Royce. The...-Royce plc, P.O. Box 31, Derby, DE24 8BJ, United Kingdom: Telephone 44 (0) 1332 242424; fax 44 (0) 1332...

  9. 77 FR 10355 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines

    2012-02-22

    ... Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines AGENCY: Federal Aviation... service of certain critical engine parts based on reduced life limits. This new AD reduces the life limits... effective March 28, 2012. ADDRESSES: For service information identified in this AD, contact Rolls-Royce plc...

  10. 77 FR 4648 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-535 Series Turbofan Engine

    2012-01-31

    ... Airworthiness Directives; Rolls-Royce plc (RR) RB211-535 Series Turbofan Engine AGENCY: Federal Aviation... identified in this AD, contact Rolls-Royce plc, P.O. Box 31, Derby, DE24 8BJ, United Kingdom; phone: 011 44... parts are required. Based on these figures, we estimate the cost of this AD on U.S. operators to be $1...

  11. 75 FR 63727 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-524 Series Turbofan Engines

    2010-10-18

    ...-0162; Directorate Identifier 2004-NE-19-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR...-2251. Contact Rolls-Royce plc, P.O. Box 31, Derby, DE24 8BJ, United Kingdom; telephone: 011-44-1332... would cost $0. Based on these figures, we estimate the total cost of the AD to U.S. operators would be...

  12. 77 FR 1009 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-524 Series Turbofan Engines

    2012-01-09

    ... Airworthiness Directives; Rolls-Royce plc (RR) RB211-524 Series Turbofan Engines AGENCY: Federal Aviation... 5, 2005). ADDRESSES: For service information identified in this AD, contact Rolls-Royce plc, P.O...,000. Based on these figures, we estimate the total cost of the AD to U.S. operators to be $4,206,960...

  13. 75 FR 17630 - Airworthiness Directives; Rolls-Royce plc RB211 Trent 700 and Trent 800 Series Turbofan Engines

    2010-04-07

    ...-0364; Directorate Identifier 2009-NE-27-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc... based on those comments. We will post all comments we receive, without change, to http://www.regulations... Service Information Rolls-Royce plc has issued Alert Service Bulletin RB.211-72-AG086, dated December 4...

  14. 77 FR 21588 - Hart and Cooley, Inc., A Subsidiary of Tomkins, PLC Including On-Site Leased Workers from...

    2012-04-10

    ... Subsidiary of Tomkins, PLC Including On- Site Leased Workers from Reliable, Masiello Employment Services..., applicable to workers of Hart and Cooley, Inc., a subsidiary of Tomkins, PLC, including on-site leased... workers. Based on these findings, the Department is amending this certification to include workers leased...

  15. 76 FR 72650 - Airworthiness Directives; Rolls-Royce plc (RR) RB211 Trent 800 Series Turbofan Engines

    2011-11-25

    ...-0959; Directorate Identifier 2011-NE-25-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR... holidays. Fax: (202) 493-2251. Contact Rolls-Royce plc, P.O. Box 31, Derby, DE24 8BJ, United Kingdom; phone... AD. We will consider all comments received by the closing date and may amend this proposed AD based...

  16. The YvfTU Two-component System is involved in plcR expression in Bacillus cereus

    Brillard, Julien; Susanna, Kim; Michaud, Caroline; Dargaignaratz, Claire; Gohar, Michel; Nielsen-Leroux, Christina; Ramarao, Nalini; Kolsto, Anne-Brit; Nguyen-The, Christophe; Lereclus, Didier; Broussolle, Veronique

    2008-01-01

    Background: Most extracellular virulence factors produced by Bacillus cereus are regulated by the pleiotropic transcriptional activator PlcR. Among strains belonging to the B. cereus group, the plcR gene is always located in the vicinity of genes encoding the YvfTU two-component system. The putative

  17. 75 FR 34172 - Rexam Closure Systems, Inc., a Subsidiary of Rexam PLC, Including On-Site Leased Workers From...

    2010-06-16

    ... Illinois Manufacturing, Hamlet, NC; Amended Certification Regarding Eligibility To Apply for Worker... PLC, Hamlet, North Carolina. The notice was published in the Federal Register on April 23, 2010 (75 FR... at the Hamlet, North Carolina location of Rexam Closure Systems, Inc., a subsidiary of Rexam PLC. The...

  18. Biochemical characterization of the tomato phosphatidylinositol-specific phospholipase C (PI-PLC) family and its role in plant immunity

    Abd-El-Haliem, Ahmed; Vossen, J.H.; Zeijl, van Arjan; Dezhsetan, Sara; Testerink, Christa; Seidl, M.F.; Beck, Martina; Strutt, James; Robatzek, Silke; Joosten, M.H.A.J.

    2016-01-01

    Plants possess effective mechanisms to quickly respond to biotic and abiotic stresses. The rapid activation of phosphatidylinositol-specific phospholipase C (PLC) enzymes occurs early after the stimulation of plant immune-receptors. Genomes of different plant species encode multiple PLC homologs

  19. Acemind new indoor full duplex optical wireless communication prototype

    Bouchet, Olivier; Perrufel, Micheline; Topsu, Suat; Guan, Hongyu

    2016-09-01

    For over a century and Mr. Guglielmo Marconi invention, systems using radio waves have controlled over wireless telecommunication solutions; from Amplitude Modulation (AM) radio products to satellite communications for instance. But beyond an increasingly negative opinion face to radio waves and radio spectrum availability more and more reduced; there is an unprecedented opportunity with LED installation in displays and lighting to provide optical wireless communication solutions. As a result, technologically mature solutions are already commercially available for services such as Location Based Services (LBS), broadcast diffusion or Intelligent Transport Services (ITS). Pending finalization of the standard review process IEEE 802.15.7 r1, our paper presents the results of the European collaborative project named "ACEMIND". It offers an indoor bilateral optical wireless communication prototype having the following characteristics: use of the existing electrical infrastructure, through judicious combination with Light Fidelity (LiFi), Power Line Communication (PLC) and Ethernet to reduce the implementation cost. We propose a bilateral optical wireless communication even when the light is switched off by using Visible Light Communication (VLC) and Infra-Red Communication (IRC) combined to a remote optical switch. Dimensionally optimized LiFi module is presented in order to offer the possibility for integration inside a laptop. Finally, there is operational mechanism implementation such as OFDM/DMT to increase throughput. After the introduction, we will present the results of a market study from Orange Labs customers about their opinion on LiFi components. Then we will detail the LiFi prototype, from the physical layer aspect to MAC layer before concluding on commercial development prospects.

  20. Child protection and new technologies of communication: the code of regulatory PEGI videogames and games on-line

    Petra Mª PÉREZ ALONSO-GETA

    2017-07-01

    Full Text Available It’s been said that the future of a village resides in its children, and not only because they’re the future, but because it’s better if we protect and teach our children well. Thus, in 1959 the United Nations published ten principles in the Declaration of the Rights of the Child. The second principle of the Declaration of the Rights states that “the child shall enjoy special protection…to enable him to develop physically, mentally, morally, spiritually and socially…” Today, a very different social context from that of 1959, the right to protection should also be settled within the diverse areas that define new communication technologies. However, current procedures established by the PEGI, while still necessary, don’t guarantee this basic childhood right.

  1. Nutritional secondary hyperparathyroidism in a white lion cub (Panthera leo, with concomitant radiographic double cortical line : clinical communication

    V. Herz

    2004-06-01

    Full Text Available A captive-bred white lion cub was presented with hindquarter pain, lameness and reluctance to move. Radiographs revealed generalised osteoapenia, multiple fractures, a severely collapsed pelvic girdle, bilateral lateral bowing of the scapulae and mild kyphosis of the caudal vertebrae.Adouble cortical line, a distinct sign of osteopaenia, was repeatedly seen on the pelvic limbs, most strikingly along both femurs. Based on radiographic findings and a history of an exclusive meat diet since weaning, a diagnosis of nutritional secondary hyperparathyroidism was made. The diet was changed to a commercial kitten food and the cub was given cage rest for 6 weeks. Signs of pain abated and the cub became more active.A guarded prognosis was given for full recovery, as changes to the pelvis were considered potentially irreversible.

  2. Information and Communication Technologies in the Improvement of the Legislative Process: Main Lines for a Legislative Process More Interactive

    João Victor Rozatti Longhi

    2015-12-01

    Full Text Available Information and Communication Technologies (ICTs definitely transformed contemporary society. There are many behaviors that have changed under the massive use of such technologies, coming to public and private institutions and the law as a whole. In the formation of political will, in turn, ICTs have played increasingly important role. This work has as main objective to study the possibility of making true the intersection between technology and policy deliberation is a possible reality in Brazil. To do this, first, briefly reviews the study of two of these experiences, enshrined in several studies for its pioneering. The first concerns the Estonian reality of online electronic voting. The second is the Icelandic experience in 2011, known by the high degree of interactivity and colaborativity during the process. Finally, in the second part, we seek through a raid on democracy models see if Brazil is prepared to continue the evolution of its democratic model towards a greater degree of participation. And the main hypothesis is that interactivity can become rule through the legislative process.

  3. Applying Hamming Code to Memory System of Safety Grade PLC (POSAFE-Q) Processor Module

    Kim, Taehee; Hwang, Sungjae; Park, Gangmin

    2013-01-01

    If some errors such as inverted bits occur in the memory, instructions and data will be corrupted. As a result, the PLC may execute the wrong instructions or refer to the wrong data. Hamming Code can be considered as the solution for mitigating this mis operation. In this paper, we apply hamming Code, then, we inspect whether hamming code is suitable for to the memory system of the processor module. In this paper, we applied hamming code to existing safety grade PLC (POSAFE-Q). Inspection data are collected and they will be referred for improving the PLC in terms of the soundness. In our future work, we will try to improve time delay caused by hamming calculation. It will include CPLD optimization and memory architecture or parts alteration. In addition to these hamming code-based works, we will explore any methodologies such as mirroring for the soundness of safety grade PLC. Hamming code-based works can correct bit errors, but they have limitation in multi bits errors

  4. Trust and Collaboration in PLC Teams: Teacher Relationships, Principal Support, and Collaborative Benefits

    Hallam, Pamela R.; Smith, Henry R.; Hite, Julie M.; Hite, Steven J.; Wilcox, Bradley R.

    2015-01-01

    Professional learning communities (PLCs) are being recognized as effective in improving teacher collaboration and student achievement. Trust is critical in effectively implementing the PLC model, and the school principal is best positioned to influence school trust levels. Using five facets of trust, this research sought to clarify the impact of…

  5. A RESEARCH ON SEAMLESS PLATFORM CHANGE OF REACTOR PROTECTION SYSTEM FROM PLC TO FPGA

    JUNBEOM YOO

    2013-08-01

    Full Text Available The PLC (Programmable Logic Controller has been widely used to implement real-time controllers in nuclear RPSs (Reactor Protection Systems. Increasing complexity and maintenance cost, however, are now demanding more powerful and cost-effective implementation such as FPGA (Field-Programmable Gate Array. Abandoning all experience and knowledge accumulated over the decades and starting an all-new development approach is too risky for such safety-critical systems. This paper proposes an RPS software development process with a platform change from PLC to FPGA, while retaining all outputs from the established development. This paper transforms FBD designs of the PLC-based software development into a behaviorally-equivalent Verilog program, which is a starting point of a typical FPGA-based hardware development. We expect that the proposed software development process can bridge the gap between two software developing approaches with different platforms, such as PLC and FPGA. This paper also demonstrates its effectiveness using an example of a prototype version of a real-world RPS in Korea.

  6. A Remote PLC Laboratory (RLab) for Distance Practical Work of Industrial Automation

    Haritman, E.; Somantri, Y.; Wahyudin, D.; Mulyana, E.

    2018-02-01

    A laboratory is an essential equipment for engineering students to do a useful practical work. Therefore, universities should provide an adequate facility for practical work. On the other hand, industrial automation laboratory would offer students beneficial experience by using various educational PLC kits. This paper describes the development of Web-based Programmable Logic Controller (PLC) remote laboratory called RLab. It provides an environment for learners to study PLC application to control the level of the non-interacting tank. The RLab architecture is based on a Moodle and Remote Desktop, which also manages the booking system of the schedule of practical work in the laboratory. The RLab equipped by USB cameras providing a real-time view of PLC environment. To provide a secured system, the RLab combines Moodle and Remote Desktop application for the authentication system and management of remote users. Moodle will send PartnerID and password to connect to TeamViewer. It has been examined that the laboratory requirement, time and flexibility restrictions constitute a significant obstacle facing traditional students desiring to finish the course. A remote access laboratory can be eliminating time and flexibility restrictions. The preliminary study of RLab usability proved that such system is adequate to give the learners a distance practical work environment.

  7. 78 FR 20509 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-04-05

    ... Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed rulemaking...) RB211-535E4-B-37 series turbofan engines. This proposed AD was prompted by recalculating the life of.... (c) Applicability This AD applies to Rolls-Royce plc (RR) RB211-535E4-B-37 series turbofan engines...

  8. 78 FR 70487 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-11-26

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... turbofan engines. This AD requires removal of certain high-pressure (HP) and intermediate-pressure (IP..., RB211 Trent 768-60, 772-60, and 772B-60 turbofan engines with turbine disc part numbers (P/Ns) and...

  9. 77 FR 39157 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2012-07-02

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT...-84, and 980-84 turbofan engines. That AD currently requires inspecting the intermediate-pressure (IP... RR model RB211-Trent 970-84, 970B-84, 972-84, 972B-84, 977-84, 977B-84, and 980-84 turbofan engines...

  10. 78 FR 5 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-01-02

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT...-535E4-C-37 turbofan engines. This AD was prompted by an investigation by RR concluding that certain...- 535E4-B-37; RB211-535E4-B-75; and RB211-535E4-C-37 turbofan engines with intermediate-pressure (IP...

  11. 78 FR 37703 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-06-24

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... (RR) model RB211 Trent 768-60, 772-60, and 772B-60 turbofan engines. This AD was prompted by low...) model RB211 Trent 768-60, 772-60, and 772B-60 turbofan engines. (d) Reason This AD was prompted by low...

  12. 78 FR 70489 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-11-26

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT..., and 560A2-61 turbofan engines. This AD requires replacement or repair of the low-pressure (LP...-61, 556B2-61, 560-61, and 560A2-61 turbofan engines. (d) Reason This AD was prompted by reports of...

  13. 78 FR 22180 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-04-15

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... 972B-84, RB211-Trent 977-84, RB211-Trent 977B-84, and RB211-Trent 980-84 turbofan engines. This AD... 977B-84, and RB211-Trent 980-84 turbofan engines that incorporate RR production Modification 72-G585 or...

  14. 77 FR 20508 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2012-04-05

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT...-Trent 884B-17, RB211-Trent 892-17, RB211- Trent 892B-17, and RB211-Trent 895-17 turbofan engines. That...-17, RB211- Trent 892B-17, and RB211-Trent 895-17 turbofan engines. On September 9, 2011, we also...

  15. 77 FR 58762 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2012-09-24

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT...-Trent 892-17, RB211- Trent 892B-17, and RB211-Trent 895-17 turbofan engines. That AD currently requires...-17, RB211-Trent 892B-17, and RB211-Trent 895-17 turbofan engines. (d) Unsafe Condition This AD was...

  16. 78 FR 68360 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-11-14

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... turbofan engines. The AD number is incorrect in the Regulatory text. This document corrects that error. In... turbofan engines. As published, the AD number 2013-19-17 under Sec. 39.13 [Amended], is incorrect. No other...

  17. 78 FR 61171 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-10-03

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... (RR) RB211-535E4-B-37 series turbofan engines. This AD requires removal of affected parts using a...-B-37 series turbofan engines. (d) Unsafe Condition This AD was prompted by recalculating the lives...

  18. 78 FR 5126 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-01-24

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... turbofan engines. This AD requires replacement of the fuel oil heat exchanger (FOHE). This AD was prompted...-84 turbofan engines with a fuel oil heat exchanger (FOHE), part number 47111-1241, installed. (d...

  19. Automated Translation of Safety Critical Application Software Specifications into PLC Ladder Logic

    Leucht, Kurt W.; Semmel, Glenn S.

    2008-01-01

    The numerous benefits of automatic application code generation are widely accepted within the software engineering community. A few of these benefits include raising the abstraction level of application programming, shorter product development time, lower maintenance costs, and increased code quality and consistency. Surprisingly, code generation concepts have not yet found wide acceptance and use in the field of programmable logic controller (PLC) software development. Software engineers at the NASA Kennedy Space Center (KSC) recognized the need for PLC code generation while developing their new ground checkout and launch processing system. They developed a process and a prototype software tool that automatically translates a high-level representation or specification of safety critical application software into ladder logic that executes on a PLC. This process and tool are expected to increase the reliability of the PLC code over that which is written manually, and may even lower life-cycle costs and shorten the development schedule of the new control system at KSC. This paper examines the problem domain and discusses the process and software tool that were prototyped by the KSC software engineers.

  20. Design of a PLC control program for a batch plant : VHS case study 1

    Mader, A.H.; Brinksma, E.; Wupper, H.; Bauer, N.

    2001-01-01

    This article reports on the systematic design and validation of a PLC control program for the batch plant that has been selected as a case study for the EC project on Verification of Hybrid Systems (VHS). We show how a correct design of the control program can be obtained in an incremental manner

  1. Design of a PLC Control Program for a Batch Plant - VHS Case Study 1

    Mader, Angelika H.; Brinksma, Hendrik; Wupper, H.; Bauer, N.

    2001-01-01

    This article reports on the systematic design and validation of a PLC control program for the batch plant that has been selected as a case study for the EC project on Verification of Hybrid Systems (VHS). We show how a correct design of the control program can be obtained in an incremental manner

  2. A PLC generic requirements and specification for safety-related applications in nuclear power plants

    Han, Jea Bok; Lee, C. K.; Lee, D. Y.

    2001-12-01

    This report presents the requirements and specification to be applied to the generic qualification of programmable Logic Controller(PLC), which is being developed as part of the KNICS project, 'Development of the Digital Reactor Safety Systems' of which purpose is the application to safety-related instrumentation and control systems in nuclear power plants. This report defines the essential and critical characteristics that shall be included as part of a PLC design for safety-related application. The characteristics include performance, reliability, accuracy, the overall response time from an input to the PLC exceeding it trip condition to the resulting outputs, and the specification of processors and memories in digital controller. It also specifies the quality assurance process for software development, dealing with executive software, firmware, application software tools for developing the application software, and human machine interface(HMI). In addition, this report reviews the published standards and guidelines that are required for the PLC development and the quality assurance processes such as environment requirements, seismic withstand requirements, EMI/RFI withstand requirements, and isolation test

  3. Úzkopásmová PLC komunikace pro Smart Metering

    Kubů, Jiří

    2016-01-01

    Tato bakalářská práce se zabývá úzkopásmovou PLC komunikací. V práci je popsán základní princip, rozdělení PLC komunikace, historie technologie, využívané komunikační standardy a rušení ovlivňující datovou komunikaci této technologie. V rámci této práce byly provedeny i experimentální měření v reálném prostředí s modemy od firmy Texas Instruments C2000 PLC TMDSPLCKITV4 a C2000 PLC TMDSPLCKIT-V3. Výsledky tohoto měření jsou reálné přenosové rychlosti. Dále byla vytvořena aplikace pro dálkový s...

  4. 76 FR 1985 - Airworthiness Directives; Short Brothers PLC Model SD3 Airplanes

    2011-01-12

    ... Airworthiness Directives; Short Brothers PLC Model SD3 Airplanes AGENCY: Federal Aviation Administration (FAA..., at an average labor rate of $85 per work hour. Required parts cost about $10 per product. Based on.... The average labor rate is $85 per work-hour. Based on these figures, we estimate the cost of the AD on...

  5. 75 FR 15321 - Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines

    2010-03-29

    ... Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines AGENCY: Federal Aviation Administration... Based on the service information, we estimate that this AD will affect about 138 RB211 Trent 800 series... will cost about $2,000 per engine. Based on these figures, we estimate the cost of the AD on U.S...

  6. Applying Hamming Code to Memory System of Safety Grade PLC (POSAFE-Q) Processor Module

    Kim, Taehee; Hwang, Sungjae; Park, Gangmin [POSCO Nuclear Technology, Seoul (Korea, Republic of)

    2013-05-15

    If some errors such as inverted bits occur in the memory, instructions and data will be corrupted. As a result, the PLC may execute the wrong instructions or refer to the wrong data. Hamming Code can be considered as the solution for mitigating this mis operation. In this paper, we apply hamming Code, then, we inspect whether hamming code is suitable for to the memory system of the processor module. In this paper, we applied hamming code to existing safety grade PLC (POSAFE-Q). Inspection data are collected and they will be referred for improving the PLC in terms of the soundness. In our future work, we will try to improve time delay caused by hamming calculation. It will include CPLD optimization and memory architecture or parts alteration. In addition to these hamming code-based works, we will explore any methodologies such as mirroring for the soundness of safety grade PLC. Hamming code-based works can correct bit errors, but they have limitation in multi bits errors.

  7. Methods of Certification tests PLC-Networks in Compliance Safety Information

    A. A. Balaev

    2011-12-01

    Full Text Available The aim of this research was description of the methodology of the audit plc-network to meet the requirements of information security. The technique is based on the provisions of the guidance documents and model FSTEC Russia test object methods of information on safety information.

  8. 78 FR 65313 - Actavis, Inc. a corporation, and Warner Chilott PLC; Analysis of Agreement Containing Consent...

    2013-10-31

    ... FEDERAL TRADE COMMISSION [File No. 131 0152] Actavis, Inc. a corporation, and Warner Chilott PLC... https://ftcpublic.commentworks.com/ftc/actaviswarnerconsent following the instructions on the web-based....com/ftc/actaviswarnerconsent by following the instructions on the web-based form. If this Notice...

  9. A Research on Seamless Platform Change of Reactor Protection System From PLC to FPGA

    Yoo, Junbeom; Lee, Jonghoon [Konkuk Univ., Seoul (Korea, Republic of); Lee, Jangsoo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-08-15

    The PLC (Programmable Logic Controller) has been widely used to implement real-time controllers in nuclear RPSs (Reactor Protection Systems). Increasing complexity and maintenance cost, however, are now demanding more powerful and cost-effective implementation such as FPGA (Field-Programmable Gate Array). Abandoning all experience and knowledge accumulated over the decades and starting an all-new development approach is too risky for such safety-critical systems. This paper proposes an RPS software development process with a platform change from PLC to FPGA, while retaining all outputs from the established development. This paper transforms FBD designs of the PLC-based software development into a behaviorally-equivalent Verilog program, which is a starting point of a typical FPGA-based hardware development. We expect that the proposed software development process can bridge the gap between two software developing approaches with different platforms, such as PLC and FPGA. This paper also demonstrates its effectiveness using an example of a prototype version of a real-world RPS in Korea.

  10. Power supply system on HT-7 tokamak for diagnostic neutral beam based on PLC

    Zhang Jian; Liu Baohua; Ding Tonghai; Du Shaowu

    2006-01-01

    A power supply system for diagnostic neutral beam on the HT-7 Tokamak was developed. Its logic control system based on S7-300 PLC was described. The experimental results show that the system is easy to operate and its performance is reliable. (authors)

  11. A Research on Seamless Platform Change of Reactor Protection System From PLC to FPGA

    Yoo, Junbeom; Lee, Jonghoon; Lee, Jangsoo

    2013-01-01

    The PLC (Programmable Logic Controller) has been widely used to implement real-time controllers in nuclear RPSs (Reactor Protection Systems). Increasing complexity and maintenance cost, however, are now demanding more powerful and cost-effective implementation such as FPGA (Field-Programmable Gate Array). Abandoning all experience and knowledge accumulated over the decades and starting an all-new development approach is too risky for such safety-critical systems. This paper proposes an RPS software development process with a platform change from PLC to FPGA, while retaining all outputs from the established development. This paper transforms FBD designs of the PLC-based software development into a behaviorally-equivalent Verilog program, which is a starting point of a typical FPGA-based hardware development. We expect that the proposed software development process can bridge the gap between two software developing approaches with different platforms, such as PLC and FPGA. This paper also demonstrates its effectiveness using an example of a prototype version of a real-world RPS in Korea

  12. 76 FR 25353 - Hikma Pharmaceuticals PLC; Analysis of Agreement Containing Consent Orders To Aid Public Comment

    2011-05-04

    ... FEDERAL TRADE COMMISSION [File No. 111 0051] Hikma Pharmaceuticals PLC; Analysis of Agreement...-based form. To ensure that the Commission considers an electronic comment, you must file it on the Web-based form at the Web link: https://ftcpublic.commentworks.com/ftc/hikmabaxter . If this Notice appears...

  13. Five Year Retrospective Study of the Financial Situation of Northern Foods Plc., United Kingdom

    Louie DACOSTA

    2016-09-01

    Full Text Available This study was conducted as a retrospective analysis of Northern Foods Plc., once a major player in FTSE 350 Food Sector, to evaluate its financial situation over a five year period. The ex post factor research design was used for this study. Annual reports and databases on Northern Foods Plc., and Associated British Foods Plc., were used to perform a series of ratio analyses. The results revealed that Northern Foods Plc.’s performance has been declining as evidenced in the profitability ratios calculated. Also, financial strength was weak and working capital has not been effectively managed, hence affecting its cash and profit generation potentials. The company was limited in its ability to grow and expand as it needed to regularly fund its pension deficit, and finance its high levels of debt. The study concludes that Northern Foods was not in a very strong financial position, yet it was not making the required investments to improve, hence its takeover though this paper will not rule out non-financial issues. Furthermore, the study prescribed five generic points to improve the financial health of any organisation.

  14. Wavelet-OFDM Signal Transmission Characteristics with High-Speed PLC Modem

    Nakagawa, Kenichi; Tokuda, Masamitsu; Igata, Yuji

    In this paper, we measured the interference immunity characteristics of high-speed PLC system using Wavelet-OFDM when the narrowband conducted interference wave signal was injected. As the results, it was clear that (1) measured PHY rate at the all frequency band hardly decreased in C/I (Carrier to Interference ratio) of above 20dB, but began to decrease rapidly in C/I of below 0dB when the interference signal was injected in the frequency band of high-speed PLC signal, (2) when C/I became from 0dB to -20dB, the measured PHY rate at the frequency existing the notch band were improved around 10Mbps than that at the frequency not existing the notch band, (3) when the narrowband interference wave was injected outside of frequency band of high-speed PLC signal, the measured PHY rate did not decrease than that in each notch band. Therefore, it was revealed that high-speed PLC system using Wavelet-OFDM had good interference immunity characteristics.

  15. 76 FR 29814 - Statutory Debarment and Reinstatement of BAE Systems plc

    2011-05-23

    ... Bureau of Political-Military Affairs; Statutory Debarment and Reinstatement of BAE Systems plc and Policy... of Defense Trade Controls Compliance, Bureau of Political-Military Affairs, Department of State (202... required. Statutory debarment is based solely upon conviction in a criminal proceeding, conducted by a...

  16. Fuel cycle and waste management: A perspective from British nuclear fuels plc

    Holmes, R.G.G.; Fairhall, G.A.; Robbins, R.A.

    1996-01-01

    The phrase fuel cycle and waste management implies two separate and distinct activities. British Nuclear Fuels plc (BNFL) has adopted a holistic approach to the fuel cycle that integrates the traditional fuel cycle activities of conversion to uranium hexafluoride, fuel fabrication, power generation, and reprocessing with waste arisings, its subsequent treatment, and disposal

  17. What is the method in applying formal methods to PLC applications?

    Mader, Angelika H.; Engel, S.; Wupper, Hanno; Kowalewski, S.; Zaytoon, J.

    2000-01-01

    The question we investigate is how to obtain PLC applications with confidence in their proper functioning. Especially, we are interested in the contribution that formal methods can provide for their development. Our maxim is that the place of a particular formal method in the total picture of system

  18. Dealing with Phrase Level Co-Articulation (PLC) in speech recognition: a first approach

    Ordelman, Roeland J.F.; van Hessen, Adrianus J.; van Leeuwen, David A.; Robinson, Tony; Renals, Steve

    1999-01-01

    Whereas nowadays within-word co-articulation effects are usually sufficiently dealt with in automatic speech recognition, this is not always the case with phrase level co-articulation effects (PLC). This paper describes a first approach in dealing with phrase level co-articulation by applying these

  19. Application of PLC to dynamic control system for liquid He cryogenic pumping facility on JT-60U NBI system

    Honda, A.; Okano, F.; Ooshima, K.; Akino, N.; Kikuchi, K.; Tanai, Y.; Takenouchi, T.; Numazawa, S.; Ikeda, Y.

    2008-01-01

    The control system of the cryogenic facility in the JT-60 NBI system has been replaced by employing the PLC (Programmable Logic Controller) and SCADA (Supervisory Control And Data Acquisition) system. The original control system was constructed about 20 years ago by specifying the DCS (Distributed Control System) computer to deal with ∼400 feedback loops. Recently, troubles on this control system have increased due to its age-induced deterioration. To maintain the high reliability of the cryogenic facility, a new control system has been planned with the PLC and SCADA systems. Their attractive features include high market availability and cost-effectiveness, however, the use of PLC for such a large facility with ∼400 feedback loops has not been established because of insufficient processing capability of the early PLC. Meanwhile, the recent progress in the PLC enables to use the FBD (function block diagram) programming language for 500 function blocks. By optimizing the function blocks and connecting them in the FBD language, the feedback loops have been successfully replaced from DCS to PLC without a software developer. Moreover, an oscillation of the liquid He level, which often occurs during the cooldown mode of the cryopumps, can be automatically stabilized by easily adding a new process program in the PLC. At present, the new control system has worked well

  20. Restructuring of SE, Plc - from a functionally managed company to a process managed commercial-production company

    Ravasz, V.

    2004-01-01

    The purpose of this presentation is to inform the participants about present changes currently occurred within Slovenske elektrarne, a. s. (SE, Plc). Changes are related to the liberalisation of the electricity market and expected accession of Slovakia to EU. To support its competitiveness, the SE, Plc became a customer-oriented company, prepared to the access of strategic investor. The paper includes the basic information about centralisation and project of Restructuring of SE, Plc., which has started in December 2003. The aim of Restructuring is the change from functionally managed company to a process managed commercial-production company

  1. A Cost Effective Solution for Development Environment for Data Acquisition, Monitoring and Simulation of PLC Controlled Applications

    O. Bjelica

    2014-06-01

    Full Text Available It is very important to test and monitor the operation of Programmable Logic Controller (PLC in real time (online. Nowadays, conventional, but expensive monitoring systems for PLCs, such as Supervisory Control and Data Acquisition (SCADA systems, software and hardware simulators (or debuggers, are widely used. This paper proposes a user friendly and cost-effective development environment for monitoring, data acquisition and online simulation of applications with PLC. The purpose of this solution is to simulate the process which is controlled by the PLC. The performances of the proposed development environment are presented on the examples of washing machine and dishwasher simulators.

  2. Session 1984-1985. Radioactive waste. Minutes of evidence, Monday 13 May 1985. British Nuclear Fuels plc

    1985-01-01

    The Environment Select Committee of the House of Commons received a memorandum from British Nuclear Fuels plc on the treatment and preparation for disposal of radioactive wastes, under the headings: introduction; waste categories; waste management policy; waste arisings; waste treatment plans; appendix I - British Nuclear Fuels plc; appendix II - the nuclear fuel cycle for Magnox, AGR and LWR reactors; appendix III - control of liquid radioactive discharges from Sellafield and their environmental impact. Representatives of BNF plc were examined on the subject of the memorandum and the minutes of evidence are recorded.

  3. Session 1984-85. Radioactive waste. Minutes of evidence, Monday 13 May 1985. British Nuclear Fuels plc

    1985-01-01

    The Environment Select Committee of the House of Commons received a memorandum from British Nuclear Fuels plc on the treatment and preparation for disposal of radioactive wastes, under the headings: introduction; waste categories; waste management policy; waste arisings; waste treatment plans; appendix I - British Nuclear Fuels plc; appendix II - the nuclear fuel cycle for Magnox, AGR and LWR reactors; appendix III - control of liquid radioactive discharges from Sellafield and their environmental impact. Representatives of BNF plc were examined on the subject of the memorandum and the minutes of evidence are recorded. (U.K.)

  4. Silver linings.

    Bultas, Margaret W; Pohlman, Shawn

    2014-01-01

    The purpose of this interpretive phenomenological study was to gain a better understanding of the experiences of 11 mothers of preschool children with autism spectrum disorder (ASD). Mothers were interviewed three times over a 6 week period. Interviews were analyzed using interpretive methods. This manuscript highlights one particular theme-a positive perspective mothers described as the "silver lining." This "silver lining" represents optimism despite the adversities associated with parenting a child with ASD. A deeper understanding of this side of mothering children with ASD may help health care providers improve rapport, communication, and result in more authentic family centered care. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Data communications

    Ann, Byeong Ho; Baek, Jeong Hun

    1998-01-01

    The contents of this book are notion of data communications : summary on data communication, data transmission, data communications system, data transmission technology, data conversion, data link control and control over error of data transmission and exchange of data communications network in the first part, computer communications network architecture : data communications architecture, OSI model, lower layer of OSI model, upper layer of OSI model and distributed surroundings in the second part, data information networking : LAN, FDDI, 100 Base T, DQDB and Frame Relay in the third part, Public Network : PSDN, N-ISDN, B-ISDN in the fourth part, internet and PC communication : emulator program, Binary file, BBS, E-mail service and user on-line service in the last part.

  6. Analysis of the public debate on health hazards due to high-voltage transmission lines. Recommendations for the radiation protection related communication with respect of grid extension

    Weber, Florian; Kuehne, Olaf; Jenal, Corinna; Sanio, Tina; Langer, Kerstin; Igel, Michael

    2016-01-01

    With its phase-out of nuclear power generation and the expansion of renewably sourced energy, the German energy turnaround ('Energiewende') has radically changed existing power supply structures, with wide geographical repercussions. One aspect of this is changes to the national power grid. Existing networks are to be upgraded and new long-distance north-south power-lines built. This creates resistance and conflict. Commissioned by the Federal Office for Radiation Protection, and the Federal Ministry of the Environment, Nature Conservation, Building and Nuclear Safety, the research project entitled Analysis of public discourse on the health impacts of high-voltage power lines - recommendations for action in radiation-protection discourse related to the extension of the power grid starts precisely at the point of conflict. It first investigates from a discourse theory perspective how power grid extensions and possible health-related consequences are communicatively constructed, and what argumentation patterns dominate the discussion. From this it derives recommendations for action, with a focus on health politics information and discourse. Behind the research project stands a socio-constructivist discourse theory that sees 'social reality' not as a given but as a socially evolved entity, and its meanings, therefore, not as stable but as subject to change. The central mechanism for the communication of an objectivized social world is language. The analyses undertaken here of power grid extension are based on a methodological mix of quantitative and qualitative elements that facilitates both the differentiation of central issues and detailed examination of individual aspects. Analysis focuses on the discussion of health issues not only in the relevant literature and on civic initiative websites, but also in the first 50 Google hits, in articles from the Sueddeutsche Zeitung (SZ) and Focus, and in talk shows. The resultant discourse analysis

  7. Development of Application Programming Tool for Safety Grade PLC (POSAFE-Q)

    Koo, Kyungmo; You, Byungyong; Kim, Tae-Wook; Cho, Sengjae; Lee, Jin S.

    2006-01-01

    The pSET (POSAFE-Q Software Engineering Tool) is an application programming tool of the POSAFE-Q which is a safety graded programmable logic controller (PLC) developed for the reactor protect system of the nuclear power plant. The pSET provides an integrated development environment (IDE) which includes editors, compiler, simulator, down loader, debugger, and monitor. The pSET supports the IEC61131-3 standard software model and languages such as LD (ladder diagram) and FBD (function block diagram) which are two of the most widely used PLC programming languages in industry fields. The pSET will also support SFC (sequential function chart) language. The pSET is developed as a part of a Korea Nuclear Instrumentation and Control System (KNICS) project

  8. Saltwell PIC Skid Programmable Logic Controller (PLC) Software Configuration Management Plan

    KOCH, M.R.

    1999-01-01

    This document provides the procedures and guidelines necessary for computer software configuration management activities during the operation and maintenance phases of the Saltwell PIC Skids as required by LMH-PRO-309/Rev. 0, Computer Software Quality Assurance, Section 2.6, Software Configuration Management. The software configuration management plan (SCMP) integrates technical and administrative controls to establish and maintain technical consistency among requirements, physical configuration, and documentation for the Saltwell PIC Skid Programmable Logic Controller (PLC) software during the Hanford application, operations and maintenance. This SCMP establishes the Saltwell PIC Skid PLC Software Baseline, status changes to that baseline, and ensures that software meets design and operational requirements and is tested in accordance with their design basis

  9. Evaluation of a fast PLC module in prospect of the LHC beam interlock system

    Zaera-Sanz, Manuel

    2005-01-01

    The LHC Beam Interlock system requires a controller performing a simple matrix function to collect the different beam dump requests. To satisfy the expected safety level of the Interlock, the system should be robust and reliable. The PLC is a promising candidate to fulfil both aspects but too slow to meet the expected response time which is of the order of mseconds. Siemens has introduced a “so called” fast module (FM352-5 Boolean Processor) that provides independent and extremely fast control of a process within a larger control system using an onboard processor, a Field Programmable Gate Array (FPGA), to execute code in parallel which results in extremely fast scan times. It is interesting to investigate its features and to evaluate it as a possible candidate for the beam interlock system. This note publishes the results of this study. As well, this note could be useful for other applications requiring fast processing using a PLC.

  10. Integrated software environment dedicated for implementation of control systems based on PLC controllers

    Szymon SURMA

    2007-01-01

    Full Text Available Industrial processes’ control systems based on PLC controllers play today a very important role in all fields of transport, including also sea transport. Construction of control systems is the field of engineering, which has been continuously evolving towards maximum simplification of system design path. Up to now the time needed forthe system construction from the design to commissioning had to be divided into a few stages. A mistake made in an earlier stage caused that in most cases the next stages had to be restarted. Available debugging systems allows defect detection at an early stage of theproject implementation. The paper presents general characteristic of integrated software for implementation of complex control systems. The issues related to the software use for programming of the visualisation environment, control computer, selection oftransmission medium and transmission protocol as well as PLC controllers’ configuration, software and control have been analysed.

  11. Design and control of multifunctional sorting and training platform based on PLC control

    Wan, Hongqiang; Ge, Shuai; Han, Peiying; Li, Fancong; Zhang, Simiao

    2018-05-01

    Electromechanical integration, as a multi-disciplinary subject, has been paid much attention by universities and is widely used in the automation production of enterprises. Aiming at the problem of the lack of control among enterprises and the lack of training among colleges and universities, this paper presents a design of multifunctional sorting training platform based on PLC control. Firstly, the structure of the platform is determined and three-dimensional modeling is done. Then design the platform's aerodynamic control and electrical control. Finally, realize the platform sorting function through PLC programming and configuration software development. The training platform can be used to design the practical training experiment, which has a strong advance and pertinence in the electromechanical integration teaching. At the same time, the platform makes full use of modular thinking to make the sorting modules more flexible. Compared with the traditional training platform, its teaching effect is more significant.

  12. Comparative analysis of different configurations of PLC-based safety systems from reliability point of view

    Tapia, Moiez A.

    1993-01-01

    The study of a comparative analysis of distinct multiplex and fault-tolerant configurations for a PLC-based safety system from a reliability point of view is presented. It considers simplex, duplex and fault-tolerant triple redundancy configurations. The standby unit in case of a duplex configuration has a failure rate which is k times the failure rate of the standby unit, the value of k varying from 0 to 1. For distinct values of MTTR and MTTF of the main unit, MTBF and availability for these configurations are calculated. The effect of duplexing only the PLC module or only the sensors and the actuators module, on the MTBF of the configuration, is also presented. The results are summarized and merits and demerits of various configurations under distinct environments are discussed.

  13. Evaluation and application of a fast module in a PLC based interlock and control system

    Zaera-Sanz, M

    2009-01-01

    The LHC Beam Interlock system requires a controller performing a simple matrix function to collect the different beam dump requests. To satisfy the expected safety level of the Interlock, the system should be robust and reliable. The PLC is a promising candidate to fulfil both aspects but too slow to meet the expected response time which is of the order of μseconds. Siemens has introduced a 'so called' fast module (FM352-5 Boolean Processor). It provides independent and extremely fast control of a process within a larger control system using an onboard processor, a Field Programmable Gate Array (FPGA), to execute code in parallel which results in extremely fast scan times. It is interesting to investigate its features and to evaluate it as a possible candidate for the beam interlock system. This paper publishes the results of this study. As well, this paper could be useful for other applications requiring fast processing using a PLC.

  14. Amarogentin, a secoiridoid glycoside, abrogates platelet activation through PLC γ 2-PKC and MAPK pathways.

    Yen, Ting-Lin; Lu, Wan-Jung; Lien, Li-Ming; Thomas, Philip Aloysius; Lee, Tzu-Yin; Chiu, Hou-Chang; Sheu, Joen-Rong; Lin, Kuan-Hung

    2014-01-01

    Amarogentin, an active principle of Gentiana lutea, possess antitumorigenic, antidiabetic, and antioxidative properties. Activation of platelets is associated with intravascular thrombosis and cardiovascular diseases. The present study examined the effects of amarogentin on platelet activation. Amarogentin treatment (15~60  μM) inhibited platelet aggregation induced by collagen, but not thrombin, arachidonic acid, and U46619. Amarogentin inhibited collagen-induced phosphorylation of phospholipase C (PLC) γ2, protein kinase C (PKC), and mitogen-activated protein kinases (MAPKs). It also inhibits in vivo thrombus formation in mice. In addition, neither the guanylate cyclase inhibitor ODQ nor the adenylate cyclase inhibitor SQ22536 affected the amarogentin-mediated inhibition of platelet aggregation, which suggests that amarogentin does not regulate the levels of cyclic AMP and cyclic GMP. In conclusion, amarogentin prevents platelet activation through the inhibition of PLC γ2-PKC cascade and MAPK pathway. Our findings suggest that amarogentin may offer therapeutic potential for preventing or treating thromboembolic disorders.

  15. Saltwell Leak Detector Station Programmable Logic Controller (PLC) Software Configuration Management Plan (SCMP)

    WHITE, K.A.

    2000-01-01

    This document provides the procedures and guidelines necessary for computer software configuration management activities during the operation and maintenance phases of the Saltwell Leak Detector Stations as required by HNF-PRO-309/Rev.1, Computer Software Quality Assurance, Section 2.4, Software Configuration Management. The software configuration management plan (SCMP) integrates technical and administrative controls to establish and maintain technical consistency among requirements, physical configuration, and documentation for the Saltwell Leak Detector Station Programmable Logic Controller (PLC) software during the Hanford application, operations and maintenance. This SCMP establishes the Saltwell Leak Detector Station PLC Software Baseline, status changes to that baseline, and ensures that software meets design and operational requirements and is tested in accordance with their design basis

  16. Developing a Novel USB-PLC Controller for a Mechatronics Cloud Laboratory

    Wen-Jye Shyr

    2013-04-01

    Full Text Available This study proposes the development and implementation of a novel Universal Serial Bus (USB-Programmable Logic Controller (PLC, called a USB-PLC controller, for a mechatronics cloud laboratory. The aim of a mechatronics cloud laboratory is to provide state of the art research quality equipment to students, allowing them to conduct hands-on experiments via the Internet. One objective of the cloud laboratory is to not only provide equipment for conducting set experiments, but also to provide a means for students to access research equipment in order to conduct individual research experiments. The proposed controller for these cloud laboratory experiments has been chosen in order to expose the students to as many different engineering and technology disciplines as possible.

  17. PLC based automatic control of pasteurize mix in ice cream production

    Yao, Xudong; Liang, Kai

    2013-03-01

    This paper describes the automatic control device of pasteurized mix in the ice cream production process.We design a scheme of control system using FBD program language and develop the programmer in the STEP 7-Micro/WIN software, check for any bugs before downloading into PLC .These developed devices will able to provide flexibility and accuracy to control the step of pasteurized mix. The operator just Input the duration and temperature of pasteurized mix through control panel. All the steps will finish automatically without any intervention in a preprogrammed sequence stored in programmable logic controller (PLC). With the help of this equipment we not only can control the quality of ice cream for various conditions, but also can simplify the production process. This control system is inexpensive and can be widely used in ice cream production industry.

  18. Development of Remote Monitoring and a Control System Based on PLC and WebAccess for Learning Mechatronics

    Wen-Jye Shyr; Te-Jen Su; Chia-Ming Lin

    2013-01-01

    This study develops a novel method for learning mechatronics using remote monitoring and control, based on a programmable logic controller (PLC) and WebAccess. A mechatronics module, a Web‐CAM and a PLC were integrated with WebAccess software to organize a remote laboratory. The proposed system enables users to access the Internet for remote monitoring and control of the mechatronics module via a web browser, thereby enhancing work flexibility by enabling personnel to control mechatronics equ...

  19. Effective time management for high performance in an organization Case: Lasaco Assurance PLC

    Adeojo, Adeyinka

    2012-01-01

    The main objective of this thesis is to determine the effect of time management on high organizational performance using LASACO ASSURANCE Plc. as a case company. In this thesis, the employees working with the company were sent questionnaires. Their responses were critically analyzed and thus related to the theories. A quantitative approach was used as the methodology. According to the theory, time management is a method for managers to increase work performance effectiveness. Time man...

  20. 78 FR 54152 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-09-03

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT...; -535C-37; -535E4-37; - 535E4-B-37, and -535E4-B-75 turbofan engines, and all RB211-524G2-19; - 524G3-19; -524H2-19; and -524H-36 turbofan engines. This AD requires a one-time inspection of the front combustion...

  1. 78 FR 61168 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-10-03

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... (RR) RB211-535E4-37, RB211-535E4-B-37, RB211-535E4-C- 37, and RB211-535E4-B-75 turbofan engines. This...-37, RB211-535E4-B-37, RB211-535E4-C-37, and RB211-535E4-B-75 turbofan engines. (d) Unsafe Condition...

  2. 78 FR 60658 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-10-02

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT..., 892-17, 892B-17, and 895-17; and RB211-524G2-T-19, -524G3-T- 19, -524H-T-36, and -524H2-T-19 turbofan... (RR) model turbofan engines that have a high-pressure (HP) compressor stage 1 to 4 rotor disc...

  3. Based on the Hardware Resources Configurable Shanke PLC Building Energy Consumption Detection System

    Cheng Guanghe

    2017-01-01

    Full Text Available According to the actual situation of the comprehensive office building and the functional requirements of the building energy consumption monitoring and management system, the office building energy consumption monitoring and management system is designed by using the hardware resource configurable Shanke PLC(SKPLC as the data collector. The system uses data bus technology and field data acquisition technology to achieve the building energy consumption data acquisition and management. Practice has proved that energy-saving effect is good.

  4. 160 Gb/s OFDM transmission utilizing an all-optical symbol generator based on PLC

    Liang, Xiaojun; Qiao, Yaojun; Li, Wei; Mei, Junyao; Qin, Yi

    2009-11-01

    We demonstrate a 160 Gb/s orthogonal frequency division multiplexing (OFDM) system using an all-optical symbol generator based on planar light circuit (PLC) technology. Excellent bit error rate (BER) is observed after long-distance transmission. The proposed symbol generator fundamentally eliminates the processing speed limits introduced by electronics and is suitable for high integration, making it physically realizable to build high-speed all-optical OFDM systems with a large number of subcarriers.

  5. Capital Discipline and Financial Market Relations in Retail Globalization: Insights from the Case of Tesco plc

    Wood, Steven; Wrigley, N; Coe, NM

    2016-01-01

    This paper provides an in-depth study of leading transnational food retailer Tesco plc to explore how its financial management and relations with the investment community – notably its reputation for capital discipline – underpinned successful expansion. Informed by close dialogue with equity analysts, we investigate how this model deteriorated since the late 2000s with declining returns, leading to high-profile international divestitures. The analysis assesses the drivers of these difficulti...

  6. Business strategy and the environment Tesco Plc's declining financial performance and underlying issues

    Haddock-Millar, Julie; Rigby, Chris

    2015-01-01

    The case presents a teaching tool which requires students to: 1) analyze the financial performance of Tesco Plc over the last four years; 2) compare Tesco’s market position with key competitors; 3) identify and evaluate Tesco’s business strategy; 4) evaluate the causes of Tesco’s decline in performance; 5) develop recommendations to address declining performance; 6) identify and evaluate the Human Resource strategic role in addressing and supporting performance. The case is suitable for a bus...

  7. Turnaround and Sustainability in Economic Crisis: The Case of NEXT PLC

    Zhang, Biyan

    2013-01-01

    Purpose- against a background of continued weak economic conditions and with many firms experiencing declining financial performance, this paper presents a synthesis of the business turnaround literature and combines with analysis case –NEXT plc. It purposes to discus the turnaround strategies can keep the declining firm sustainability recovery, during the economic cycle. \\ud \\ud Design/methodology/approach- the turnaround strategy for sustainability recovery are examined by a case study of N...

  8. On Verification of PLC-Programs Written in the LD-Language

    E. V. Kuzmin

    2012-01-01

    Full Text Available We discuss some questions connected with the construction of a technology of analysing correctness of Programmable Logic Controller programs. We consider an example of modeling and automated verification of PLC-programs written in the Ladder Diagram language (including timed function blocks of the IEC 61131-3 standard. We use the Cadence SMV for symbolic model checking. Program properties are written in the linear-time temporal logic LTL.

  9. PEMBUATAN SISTEM KONTROL MESIN CAULKING ROD GUIDE OTOMATIS MENGGUNAKAN PLC OMRON CPM1A

    Syahril Ardi

    2015-02-01

    Full Text Available Kenaikan tingkat produksi shock absorber perusahaan manufaktur membuat proses produksi harus berjalan dengan baik . Pipa proses pemotongan pada mendempul panduan mesin batang memiliki beberapa masalah yang harus diatasi . Untuk mengatasi masalah tersebut kemudian melakukan modifikasi mesin batang mendempul yang secara otomatis dapat mengurangi waktu siklus pada proses mendempul batang dari 4,5 detik per potong sehingga tingkat produksi memotong garis pipa dapat ditingkatkan . Sistem kontrol otomatis mendempul mesin batang panduan ini dirancang untuk menggunakan Programmable Logic Controller (PLC

  10. Drosophila fatty acid taste signals through the PLC pathway in sugar-sensing neurons.

    Pavel Masek

    Full Text Available Taste is the primary sensory system for detecting food quality and palatability. Drosophila detects five distinct taste modalities that include sweet, bitter, salt, water, and the taste of carbonation. Of these, sweet-sensing neurons appear to have utility for the detection of nutritionally rich food while bitter-sensing neurons signal toxicity and confer repulsion. Growing evidence in mammals suggests that taste for fatty acids (FAs signals the presence of dietary lipids and promotes feeding. While flies appear to be attracted to fatty acids, the neural basis for fatty acid detection and attraction are unclear. Here, we demonstrate that a range of FAs are detected by the fly gustatory system and elicit a robust feeding response. Flies lacking olfactory organs respond robustly to FAs, confirming that FA attraction is mediated through the gustatory system. Furthermore, flies detect FAs independent of pH, suggesting the molecular basis for FA taste is not due to acidity. We show that low and medium concentrations of FAs serve as an appetitive signal and they are detected exclusively through the same subset of neurons that sense appetitive sweet substances, including most sugars. In mammals, taste perception of sweet and bitter substances is dependent on phospholipase C (PLC signaling in specialized taste buds. We find that flies mutant for norpA, a Drosophila ortholog of PLC, fail to respond to FAs. Intriguingly, norpA mutants respond normally to other tastants, including sucrose and yeast. The defect of norpA mutants can be rescued by selectively restoring norpA expression in sweet-sensing neurons, corroborating that FAs signal through sweet-sensing neurons, and suggesting PLC signaling in the gustatory system is specifically involved in FA taste. Taken together, these findings reveal that PLC function in Drosophila sweet-sensing neurons is a conserved molecular signaling pathway that confers attraction to fatty acids.

  11. The effect of a dynamic PCL brace on patellofemoral compartment pressures in PCL-and PCL/PLC-deficient knees.

    Welch, Tyler; Keller, Thomas; Maldonado, Ruben; Metzger, Melodie; Mohr, Karen; Kvitne, Ronald

    2017-12-01

    The natural history of posterior cruciate ligament (PCL) deficiency includes the development of arthrosis in the patellofemoral joint (PFJ). The purpose of this biomechanical study was to evaluate the hypothesis that dynamic bracing reduces PFJ pressures in PCL- and combined PCL/posterolateral corner (PLC)-deficient knees. Controlled Laboratory Study. Eight fresh frozen cadaveric knees with intact cruciate and collateral ligaments were included. PFJ pressures and force were measured using a pressure mapping system via a lateral arthrotomy at knee flexion angles of 30°, 60°, 90°, and 120° in intact, PCL-deficient, and PCL/PLC-deficient knees under a combined quadriceps/hamstrings load of 400 N/200 N. Testing was then repeated in PCL- and PCL/PLC-deficient knees after application of a dynamic PCL brace. Application of a dynamic PCL brace led to a reduction in peak PFJ pressures in PCL-deficient knees. In addition, the brace led to a significant reduction in peak pressures in PCL/PLC-deficient knees at 60°, 90°, and 120° of flexion. Application of the dynamic brace also led to a reduction in total PFJ force across all flexion angles for both PCL- and PCL/PLC-deficient knees. Dynamic bracing reduces PFJ pressures in PCL- and combined PCL/PLC-deficient knees, particularly at high degrees of knee flexion.

  12. Modeling of Hydration, Compressive Strength, and Carbonation of Portland-Limestone Cement (PLC Concrete

    Xiao-Yong Wang

    2017-01-01

    Full Text Available Limestone is widely used in the construction industry to produce Portland limestone cement (PLC concrete. Systematic evaluations of hydration kinetics, compressive strength development, and carbonation resistance are crucial for the rational use of limestone. This study presents a hydration-based model for evaluating the influences of limestone on the strength and carbonation of concrete. First, the hydration model analyzes the dilution effect and the nucleation effect of limestone during the hydration of cement. The degree of cement hydration is calculated by considering concrete mixing proportions, binder properties, and curing conditions. Second, by using the gel–space ratio, the compressive strength of PLC concrete is evaluated. The interactions among water-to-binder ratio, limestone replacement ratio, and strength development are highlighted. Third, the carbonate material contents and porosity are calculated from the hydration model and are used as input parameters for the carbonation model. By considering concrete microstructures and environmental conditions, the carbon dioxide diffusivity and carbonation depth of PLC concrete are evaluated. The proposed model has been determined to be valid for concrete with various water-to-binder ratios, limestone contents, and curing periods.

  13. Praksisnær skoleudvikling og PLC som strategisk udviklingsaktør

    Christensen, Ole; Bach, Anna

    2017-01-01

    I det følgende belyses, hvorledes PLC kan udvikles som strategisk udviklingsaktør og understøtte praksisnær skoleudvikling. Vi ønsker at belyse hvorledes Bekendtgørelsens overordnede intentioner kan få retning og rammer og dermed medvirke til, at hele det pædagogiske personale indgår i skoleudvik......I det følgende belyses, hvorledes PLC kan udvikles som strategisk udviklingsaktør og understøtte praksisnær skoleudvikling. Vi ønsker at belyse hvorledes Bekendtgørelsens overordnede intentioner kan få retning og rammer og dermed medvirke til, at hele det pædagogiske personale indgår i...... skoleudviklingen. I den forbindelse er det vores erfaring, at PLC kan spille en central rolle i forbindelse med den praksisnære og lokale skoleudvikling. Erfaringerne bygger især på udviklings- og forskningsprojekter fra kommunerne Kolding, København, Roskilde og Tårnby. Der har været tale om praksisnære...

  14. Molecular characterization of severin from Clonorchis sinensis excretory/secretory products and its potential anti-apoptotic role in hepatocarcinoma PLC cells.

    Xueqing Chen

    Full Text Available BACKGROUND: Clonorchiasis, caused by the infection of Clonorchis sinensis (C. sinensis, is a kind of neglected tropical disease, but it is highly related to cholangiocarcinoma and hepatocellular carcinoma (HCC. It has been well known that the excretory/secretory products of C. sinensis (CsESPs play key roles in clonorchiasis associated carcinoma. From genome and transcriptome of C. sinensis, we identified one component of CsESPs, severin (Csseverin, which had three putative gelsolin domains. Its homologues are supposed to play a vital role in apoptosis resistance of tumour cell. METHODOLOGY/PRINCIPAL FINDINGS: There was significant similarity in tertiary structures between human gelsolin and Csseverin by bioinformatics analysis. We identified that Csseverin expressed at life stage of adult worm, metacercaria and egg by the method of quantitative real-time PCR and western blotting. Csseverin distributed in vitellarium and intrauterine eggs of adult worm and tegument of metacercaria by immunofluorence assay. We obtained recombinant Csseverin (rCsseverin and confirmed that rCsseverin could bind with calciumion in circular dichroism spectrum analysis. It was demonstrated that rCsseverin was of the capability of actin binding by gel overlay assay and immunocytochemistry. Both Annexin V/PI assay and mitochondrial membrane potential assay of human hepatocarcinoma cell line PLC showed apoptosis resistance after incubation with different concentrations of rCsseverin. Morphological analysis, apoptosis-associated changes of mitochondrial membrane potential and Annexin V/PI apoptosis assay showed that co-incubation of PLC cells with rCsseverin in vitro led to an inhibition of apoptosis induced by serum-starved for 24 h. CONCLUSIONS/SIGNIFICANCE: Collectively, the molecular properties of Csseverin, a molecule of CsESPs, were characterized in our study. rCsseverin could cause obvious apoptotic inhibition in human HCC cell line. Csseverin might exacerbate the

  15. Molecular Characterization of Severin from Clonorchis sinensis Excretory/Secretory Products and Its Potential Anti-apoptotic Role in Hepatocarcinoma PLC Cells

    He, Lei; Wang, Xiaoyun; Liang, Pei; Chen, Wenjun; Bian, Meng; Ren, Mengyu; Lin, Jinsi; Liang, Chi; Xu, Jin; Wu, Zhongdao; Li, Xuerong; Huang, Yan; Yu, Xinbing

    2013-01-01

    Background Clonorchiasis, caused by the infection of Clonorchis sinensis (C. sinensis), is a kind of neglected tropical disease, but it is highly related to cholangiocarcinoma and hepatocellular carcinoma (HCC). It has been well known that the excretory/secretory products of C. sinensis (CsESPs) play key roles in clonorchiasis associated carcinoma. From genome and transcriptome of C. sinensis, we identified one component of CsESPs, severin (Csseverin), which had three putative gelsolin domains. Its homologues are supposed to play a vital role in apoptosis resistance of tumour cell. Methodology/Principal Findings There was significant similarity in tertiary structures between human gelsolin and Csseverin by bioinformatics analysis. We identified that Csseverin expressed at life stage of adult worm, metacercaria and egg by the method of quantitative real-time PCR and western blotting. Csseverin distributed in vitellarium and intrauterine eggs of adult worm and tegument of metacercaria by immunofluorence assay. We obtained recombinant Csseverin (rCsseverin) and confirmed that rCsseverin could bind with calciumion in circular dichroism spectrum analysis. It was demonstrated that rCsseverin was of the capability of actin binding by gel overlay assay and immunocytochemistry. Both Annexin V/PI assay and mitochondrial membrane potential assay of human hepatocarcinoma cell line PLC showed apoptosis resistance after incubation with different concentrations of rCsseverin. Morphological analysis, apoptosis-associated changes of mitochondrial membrane potential and Annexin V/PI apoptosis assay showed that co-incubation of PLC cells with rCsseverin in vitro led to an inhibition of apoptosis induced by serum-starved for 24 h. Conclusions/Significance Collectively, the molecular properties of Csseverin, a molecule of CsESPs, were characterized in our study. rCsseverin could cause obvious apoptotic inhibition in human HCC cell line. Csseverin might exacerbate the process of HCC

  16. Data communications and computer communications network

    Kim, Jang Gwon; Gu, Chang Hoe

    2005-03-01

    This textbook is composed of twelve chapters, which are communication network introduction, foundation of data communication, data link control, circuit switching system, packet switching system, multiple access communication system, protocol and architecture, LAN, MAN communication network, integrated service digital network, internet and Asymmetric digital subscriber Line and Wireless Local Loop. Each chapter has the introduction of the technique, structure, function and practice problems. It also has the appendix on electricity and communication standards organization, characteristic table and glossary.

  17. Prospective radiological dose assessment. Amersham plc (Amersham site) variation application December 1998

    Allott, R.

    2001-01-01

    Amersham plc (previously Nycomed-Amersham plc) submitted an application to the Environment Agency in December 1998 for a variation to their radioactive waste discharge authorisations granted under the Radioactive Substances Act 1993. The application requested a reduction in the discharge limits for certain radionuclides and no change for the remaining radionuclides. Amersham plc undertook a further review of their discharge requirements and submitted a new assessment for revised limits in January 2001. This report provides an assessment of the radiological implications of discharges at these revised limits requested by Amersham plc and the limits proposed by the Agency. It has been prepared by the National Compliance Assessment Service at the request of Thames Region to support their determination of the application. Four candidate critical groups were identified who could be exposed to discharges from the Amersham site: 1) Sewage workers at the Maple Lodge sewage works who might be exposed to external radiation from discharges contained within sewage and inadvertently inhale or ingest sewage. 2) Anglers on the Grand Union Canal who eat a small proportion of their annual catch of freshwater fish, who drink water abstracted solely from the River Colne and eat vegetables irrigated by water from the canal. 3) Persons living closest to site who eat locally produced food. 4) Dog walkers living near to site who eat locally produced food. For continuous discharges at the Agency's proposed annual limits, the highest dose of 160 μSv/y is predicted to be received by infants who live closest to the site and eat locally produced food. Therefore, this has been identified as the critical group. Children and adults living at the same location and eating locally produced food receive doses of 140 μSv/y and 130 μSv/y respectively. The critical group dose is less than the source constraint of 300 μSv/y. The dose is dominated by direct radiation from the site (110 μSv/y) and the

  18. Broadband from the socket and privatization of power distribution networks

    Aalbers, R.; Baarsma, B.; Poort, J.

    2005-01-01

    Attention is paid to the consequences for the Dutch market of the recommendation of the European Commission to introduce Power Line Communication (PLC) in the EU member states. PLC makes it possible to access the internet via sockets [nl

  19. 70Z/3 Cbl induces PLC gamma 1 activation in T lymphocytes via an alternate Lat- and Slp-76-independent signaling mechanism.

    Graham, Laurie J; Verí, Maria-Concetta; DeBell, Karen E; Noviello, Cristiana; Rawat, Rashmi; Jen, Sandy; Bonvini, Ezio; Rellahan, Barbara

    2003-04-24

    The oncoprotein 70Z/3 Cbl signals in an autonomous fashion or through blockade of endogenous c-Cbl, a negative regulator of signaling. The mechanism of 70Z/3 Cbl-induced signaling was investigated by comparing the molecular requirements for 70Z/3 Cbl- and TCR-induced phospholipase C gamma 1 (PLC gamma 1) activation. 70Z/3 Cbl-induced PLC gamma 1 tyrosine phosphorylation required, in addition to the PLC gamma 1 N-terminal SH2 domain, the C-terminal SH2 and SH3 domains that were dispensable for TCR-induced phosphorylation. Deletion of the leucine zipper of 70Z/3 Cbl did not eliminate 70Z/3 Cbl-induced PLC gamma 1 phosphorylation, suggesting that blockage of c-Cbl via dimerization with 70Z/3 Cbl cannot fully explain 70Z/3 Cbl activating characteristics. The complete elimination of PLC gamma 1 phosphorylation required deleting the SH3 domain-binding region of 70Z/3 Cbl, consistent with 70Z/3 Cbl binding the PLC gamma 1 SH3 domain. 70Z/3 Cbl-induced PLC gamma 1 phosphorylation required Zap-70, as for the TCR, and the tyrosine kinase binding domain of 70Z/3 Cbl, which binds Zap-70, but did not require PLC gamma 1 binding to Lat, a crucial interaction in TCR-induced PLC gamma 1 phosphorylation. Furthermore, 70Z/3 Cbl-induced activation of NFAT, a PLC gamma 1/Ca(2+)-dependent transcriptional event, required Zap-70, but was independent of Slp-76, an adapter required for TCR-induced NFAT activation. These results suggest that 70Z/3 Cbl and PLC gamma 1 form a TCR-, Lat- and Slp-76-independent complex that leads to PLC gamma 1 phosphorylation and activation.

  20. 数据仓库与OLAP在通信线路状态统计中的应用%Application of Data Warehouse and OLAP in Preference Data Analysis on Communication Line State Statistics

    刘淑娟; 岳鹏

    2012-01-01

    In recent years, with the rapid development of the communication industry, more and more broadband accessed. Customers on the bandwidth and broadband quality put forward higher requirement, how to reduce the operation and maintenance costs, and improve network quality are the biggest problem for corporations. So corporations must have a whole understanding for the communication line state. As the above problems, this paper according to the enterprise to communication line state statistics demand, through the application of data warehouse and OLAP technology for the original communication lines state statistics the multi-dimensional data analysis, makes a practical scheme for line state statistical. This plan can offer reference in telecommunications companies in line state statistics.%近年来,随着通信行业的飞速发展,宽带接入的用户越来越多.客户对带宽和宽带的质量提出更高的要求,如何降低运营成本,提升网络质量,是宽带运营商运行维护面临的最大问题.因此,企业必须对通信线路的运行维护状况有一个整体的了解.本文针对以上的问题,根据企业对通信线路状态统计的需求,通过运用数据仓库及OLAP技术,对原有的通信线路状态统计的相关数据进行多维分析,制定一套切实可行的线路状态统计方案,此方案可供通信企业在线路状态统计中参考.

  1. 3D digital image correlation investigation of PLC effect in a new Ni-Co base superalloy

    Gao, Y.; Fu, S. H.; Cheng, T.; Huo, X.; Zhang, Q. C.

    2013-06-01

    Repeated plastic instability accompanying serrated yielding in stress-strain curves and localization of deformation is observed during plastic deformation of many metallic alloys when tensile specimens are deformed under certain experimental conditions of temperature, strain rate, and pre-deformation. This phenomenon is referred to as the Portevin- Le Chatelier (PLC) effect. TMW alloy, a newly developed Ni-Co base superalloy for aircraft engine application, also exhibit PLC effect during tensile test at temperatures ranging from 300 ° to 600 °, which are also the temperature range for engine working. In this paper, a 3D digital image correlation (3D DIC) measurement system was established to observe the localization of deformation (PLC band) in a tensile test performed on TMW alloy specimen at temperature of 400 °. The 3D DIC system, with displacement measurement accuracy up to 0.01 pixels and strain measurement accuracy up to 100 μɛ, has a high performance in displacement field calculation with more than 10000 points every second on a 3.1G Hz CPU computer. The test result shows that, the PLC bands are inclined at an angle of about 60° to the tensile axis. Unlike tensile test performed on aluminums alloy, the widths of PLC bands of TMW alloy specimen, ranging from 4 mm to 4.5 mm, are much greater than the specimen thickness (0.25 mm).

  2. Construction of a multi-vender fieldbus system for PC-based control using soft PLC

    Park, J. H.; Park, Y. J.; Choi, J. M.; Park, J. S. [Hankyong National Univ., Ansung (Korea)

    2000-12-01

    The relationship between the IEC 61131-3 programming language and the fieldbus application that became necessary as an outcome of the recent automation technology was described.An educational text for the field users on the integration of the Input/Output (I/O) modules and on the IEC 61131-3 programming language was prepared. An attempt was made to include description of the various kind of the fieldbuses and promote understanding of the CAN and the AS-I bus using a practical approach. The profibus is most widely used in the world, and thus is an important and a standardized tool in the area of the process control. A method of integrating the profibus with the most commonly used I/O modules in the field was suggested. The most essential characteristics of the IEC 61131-3 programming language was also described. A method for the construction of the multi-vender I/O modules by the Soft PLC 4C of the softings was suggested. Various technical steps are necessary for the integration of the I/O modules by the soft PLC. An additional software is needed for the more intelligent devises possessing complex technical functions, such as the control valve, the AC driver among others. The 4C control by the softing which is an important industrial solution for the soft PLC was specifically designed for the profibus. So, an OPC server is needed to exchange between the other fieldbuses while the optimum performance is only achieved by using the profibus card by softing. This implies that the business aspect has played a major role for developing the profibus by softing and the domestic users need to pay careful attention to this point additional software tools, such as the PDM or the comuwinn II, are necessary in the process control area to operate a complex and instruments using the DP/PA segment coupler. 13 refs., 46 figs., 12 tabs. (Author)

  3. Generating Safety-Critical PLC Code From a High-Level Application Software Specification

    2008-01-01

    The benefits of automatic-application code generation are widely accepted within the software engineering community. These benefits include raised abstraction level of application programming, shorter product development time, lower maintenance costs, and increased code quality and consistency. Surprisingly, code generation concepts have not yet found wide acceptance and use in the field of programmable logic controller (PLC) software development. Software engineers at Kennedy Space Center recognized the need for PLC code generation while developing the new ground checkout and launch processing system, called the Launch Control System (LCS). Engineers developed a process and a prototype software tool that automatically translates a high-level representation or specification of application software into ladder logic that executes on a PLC. All the computer hardware in the LCS is planned to be commercial off the shelf (COTS), including industrial controllers or PLCs that are connected to the sensors and end items out in the field. Most of the software in LCS is also planned to be COTS, with only small adapter software modules that must be developed in order to interface between the various COTS software products. A domain-specific language (DSL) is a programming language designed to perform tasks and to solve problems in a particular domain, such as ground processing of launch vehicles. The LCS engineers created a DSL for developing test sequences of ground checkout and launch operations of future launch vehicle and spacecraft elements, and they are developing a tabular specification format that uses the DSL keywords and functions familiar to the ground and flight system users. The tabular specification format, or tabular spec, allows most ground and flight system users to document how the application software is intended to function and requires little or no software programming knowledge or experience. A small sample from a prototype tabular spec application is

  4. Melatonin potentiates glycine currents through a PLC/PKC signalling pathway in rat retinal ganglion cells.

    Zhao, Wen-Jie; Zhang, Min; Miao, Yanying; Yang, Xiong-Li; Wang, Zhongfeng

    2010-07-15

    In vertebrate retina, melatonin regulates various physiological functions. In this work we investigated the mechanisms underlying melatonin-induced potentiation of glycine currents in rat retinal ganglion cells (RGCs). Immunofluorescence double labelling showed that rat RGCs were solely immunoreactive to melatonin MT(2) receptors. Melatonin potentiated glycine currents of RGCs, which was reversed by the MT(2) receptor antagonist 4-P-PDOT. The melatonin effect was blocked by intracellular dialysis of GDP-beta-S. Either preincubation with pertussis toxin or application of the phosphatidylcholine (PC)-specific phospholipase C (PLC) inhibitor D609, but not the phosphatidylinositol (PI)-PLC inhibitor U73122, blocked the melatonin effect. The protein kinase C (PKC) activator PMA potentiated the glycine currents and in the presence of PMA melatonin failed to cause further potentiation of the currents, whereas application of the PKC inhibitor bisindolylmaleimide IV abolished the melatonin-induced potentiation. The melatonin effect persisted when [Ca(2+)](i) was chelated by BAPTA, and melatonin induced no increase in [Ca(2+)](i). Neither cAMP-PKA nor cGMP-PKG signalling pathways seemed to be involved because 8-Br-cAMP or 8-Br-cGMP failed to cause potentiation of the glycine currents and both the PKA inhibitor H-89 and the PKG inhibitor KT5823 did not block the melatonin-induced potentiation. In consequence, a distinct PC-PLC/PKC signalling pathway, following the activation of G(i/o)-coupled MT(2) receptors, is most likely responsible for the melatonin-induced potentiation of glycine currents of rat RGCs. Furthermore, in rat retinal slices melatonin potentiated light-evoked glycine receptor-mediated inhibitory postsynaptic currents in RGCs. These results suggest that melatonin, being at higher levels at night, may help animals to detect positive or negative contrast in night vision by modulating inhibitory signals largely mediated by glycinergic amacrine cells in the inner

  5. Realization of Intelligent Measurement and Control System for Limb Rehabilitation Based on PLC and Touch Screen

    Liu, Xiangquan

    According to the treatment needs of patients with limb movement disorder, on the basis of the limb rehabilitative training prototype, function of measure and control system are analyzed, design of system hardware and software is completed. The touch screen which is adopt as host computer and man-machine interaction window is responsible for sending commands and training information display; The PLC which is adopt as slave computer is responsible for receiving control command from touch screen, collecting the sensor data, regulating torque and speed of motor by analog output according to the different training mode, realizing ultimately active and passive training for limb rehabilitation therapy.

  6. Design and realization of the waster level system based on PLC and configuration technology

    Hu Kaiming; Ge Yuanxiang; Fu Zhijian

    2012-01-01

    The process control experimental system takes the water level as the controlled object. In this system PLC is adopted as a controller and the electric valve for the actuator. Based on the water level system in the establishment of the mathematical model, the system uses PID algorithm, the PID parameters are tuning, MCGS configuration environment is built and debugs in the environment. Experiments show that the system is running smoothly, the overshoot is 18%, the setting time is about 3 min. The control indicators have reached the engineering requirements and the control effect is good. (authors)

  7. Institutional radioactive waste management in the Nuclear Research Institute Rez plc

    Kovarik, P.; Svoboda, K.; Podlaha, J.

    2008-01-01

    Nuclear research institute Rez, plc. (mentioned below as NRI) has had a dominant position in the area of the nuclear research and development in the Czech Republic, the Central and the Eastern Europe. Naturally, the radioactive waste management is an integral part of the nuclear industry, research and development. For that reason, there is Centre of the radioactive waste management (mentioned below as Centre) in the NRI. This Centre is engaged in the radioactive waste treatment, decontamination, characterisation, decommissioning and other relevant activities. This paper describes the system of technology and other information about institutional radioactive waste management in the NRI. (authors)

  8. The Interface Between Redundant Processor Modules Of Safety Grade PLC Using Mass Storage DPRAM

    Hwang, Sung Jae; Song, Seong Hwan; No, Young Hun; Yun, Dong Hwa; Park, Gang Min; Kim, Min Gyu; Choi, Kyung Chul; Lee, Ui Taek

    2010-01-01

    Processor module of safety grade PLC (hereinafter called as POSAFE-Q) developed by POSCO ICT provides high reliability and safety. However, POSAFEQ would have suffered a malfunction when we think taking place of abnormal operation by exceptional environmental. POSAFE-Q would not able to conduct its function normally in such case. To prevent these situations, the necessity of redundant processor module has been raised. Therefore, redundant processor module, NCPU-2Q, has been developed which has not only functions of single processor module with high reliability and safety but also functions of redundant processor

  9. Aplicación de la Tecnología PLC en la provincia del Azuay

    Jara Guapisaca, Claudio Xavier

    2006-01-01

    La Red PLC utiliza infraestructura ya instalada para atender a un mercado masivo, siendo una alternativa eficiente en términos de requerimientos de capital y tiempos de ejecución. La técnica es bastante sencilla de entender; consiste en acondicionar parte de las actuales infraestructuras eléctricas para que puedan transmitir señales regulares de baja frecuencia y otras por encima de la banda de 1 MHz, sin que se vea afectado el rendimiento eléctrico. Las señales de baja frecuencia (50 ó 60...

  10. Science communication as political communication

    Scheufele, Dietram A.

    2014-01-01

    Scientific debates in modern societies often blur the lines between the science that is being debated and the political, moral, and legal implications that come with its societal applications. This manuscript traces the origins of this phenomenon to professional norms within the scientific discipline and to the nature and complexities of modern science and offers an expanded model of science communication that takes into account the political contexts in which science communication takes place. In a second step, it explores what we know from empirical work in political communication, public opinion research, and communication research about the dynamics that determine how issues are debated and attitudes are formed in political environments. Finally, it discusses how and why it will be increasingly important for science communicators to draw from these different literatures to ensure that the voice of the scientific community is heard in the broader societal debates surrounding science. PMID:25225389

  11. Science communication as political communication.

    Scheufele, Dietram A

    2014-09-16

    Scientific debates in modern societies often blur the lines between the science that is being debated and the political, moral, and legal implications that come with its societal applications. This manuscript traces the origins of this phenomenon to professional norms within the scientific discipline and to the nature and complexities of modern science and offers an expanded model of science communication that takes into account the political contexts in which science communication takes place. In a second step, it explores what we know from empirical work in political communication, public opinion research, and communication research about the dynamics that determine how issues are debated and attitudes are formed in political environments. Finally, it discusses how and why it will be increasingly important for science communicators to draw from these different literatures to ensure that the voice of the scientific community is heard in the broader societal debates surrounding science.

  12. A Multilayer Perceptron-Based Impulsive Noise Detector with Application to Power-Line-Based Sensor Networks

    Chien, Ying-Ren

    2018-04-10

    For power-line-based sensor networks, impulsive noise (IN) will dramatically degrade the data transmission rate in the power line. In this paper, we present a multilayer perceptron (MLP)-based approach to detect IN in orthogonal frequency-division multiplexing (OFDM)-based baseband power line communications (PLCs). Combining the MLP-based IN detection method with the outlier detection theory allows more accurate identification of the harmful residual IN. For OFDM-based PLC systems, the high peak-to-average power ratio (PAPR) of the received signal makes detection of harmful residual IN more challenging. The detection mechanism works in an iterative receiver that contains a pre-IN mitigation and a post-IN mitigation. The pre-IN mitigation is meant to null the stronger portion of IN, while the post-IN mitigation suppresses the residual portion of IN using an iterative process. Compared with previously reported IN detectors, the simulation results show that our MLP-based IN detector improves the resulting bit error rate (BER) performance.

  13. A Modification of Gamma Surveymeter Dosemeter 3007A for Monitoring Use Ethernet by PLC T100MD Series

    Ikhsan Shobari; Subchan, M.; Syahrudin Yusuf; Sutomo Budihardjo

    2010-01-01

    It has been modified a gamma surveymeter Dosemeter 3007A. The Surveymeter represents analogous surveymeter, so that an interface for data acquisition is required. Acquisition system from surveymeter is added to the voltage amplifier module from 0 - 200 mV to 0 - 5 V. This voltage value will represent of doses 0 - 5 mR/hour. Hereinafter the analogous signal 0 - 5 V as signal of input to peripheral of PLC T100MD series. Data in the form of processed analogous signal presented at local display of PLC. For long distance monitoring, data have been sent to a computer from PLC by ethernet. After this modification, the surveymeter can be used to monitor from long distance. By using Internet Service Provider, monitoring can be done at any time and any where as long as network internet is available. (author)

  14. Perancangan Prototype Early Warning System pada Kontrol On/Off Belt Conveyor Menggunakan PLC Siemens S7-300

    Taufik Taufik

    2016-04-01

    Full Text Available Nowadays, automation system become an important aspect of the manufacturing process because could make integration manufacturing process on it more effective and more efficient. PLC or Programmable Logic Controller is one kind of automation system. Many industries use PLC as automation control device in the manufacturing process to control all kind of process. For example at transportation process of coals in generator industry. Coals could be burned because main elements of coals are carbon, hydrogen, and oxygen. Base on this prototype early warning system design, we get the result if sensor thermocouple detects temperature larger than setpoint temperature (it is 2000C, then PLC will give an order to shut down the output, that is a belt conveyor. The result of this prototype design could use at coals transportation as an early warning system. The design of prototype early warning system could detect and prevent fire because of the consequence of burned coals until spreading of fire could be avoided.

  15. Process control through the incorporation of PLC networks in service radiation facilities

    Moehlmann, J.H.F.

    1990-01-01

    In order to ensure the smooth and safe running and operation of an irradiation facility, several regulations must be complied with, most of which are prescribed by the authorities. However, internal working regulations, based on years of practical experience, are of equal importance. The application of computers, micro-processors and PLCs, in combination with semi-conductor electronics, has improved process control considerably. Not only can every step in the process and even each detailed function be controlled, but also the combination of the different functions. By using PLC-systems in combination with computers, important data can be stored, recorded and presented in such a way that the technical staff can be warned in advance of breakdowns or undesirable deviations in the process parameters. Keeping a log of these data will help guarantee the correct functioning of the irradiation facility. It is even possible with these modern PLC techniques to monitor the control-console, so that each operation is recorded and accessible. (author)

  16. Design and construction of automatic operating system of double chamber plasma nitriding device PLC based

    Saminto; Slamet Santosa; Eko Priyono

    2012-01-01

    The automatic operating system of double chamber plasma nitriding device has been done. The system is used for operating double chamber plasma nitriding automatically as according to the standard operating procedure by pressing push button on the human machine interface (HMI). The system consists of hardware and software. The hardware was constructed using main components T100MD1616+ PLC module and supported by temperature signal conditioner module, Wheatstone bridge module, isolated amplifier module and EMS 30A H Bridge motor driver module. A software program that is planted on T100MD1616+ PLC using ladder diagrams and Tbasic program. Test system functions performed by inserting a set values of temperature and pressure by pressing the button on the human machine interface (HMI). The test results show that the temperature control with a set of values 100 °C obtained stable coverage of 98 °C to 102 °C, (Δ ± 2 °C) with a 2% tolerance and the output voltage of the DAC is 2.436 volts to 2.913 volts. The pressure control with a set of values 2.169 x 10 -1 mbar obtained stable coverage of 1.995 x 10 -1 mbar to 2.205 x 10 -1 mbar, (Δ ± 0.105 x 10 -1 mbar) with a 5% tol. (author)

  17. Controlling the Filling and Capping Operation of a Bottling Plant using PLC and SCADA

    Kunal Chakraborty

    2015-03-01

    Full Text Available This paper presents basic stages of operation of a bottling plant, i.e. the filling and capping process. The main aim of our paper is to control the filling and capping section of a bottling plant simultaneously. At first a set of empty bottle is run by using a conveyer towards filling section, after the operation, the filled bottles are sent towards the capping section. After successful capping operation, the sealed bottles terminate towards exit and a new set of empty bottle arrive, in this way the process continues. This paper includes the method using which, a bunch of bottles can be filled and capped at one instant of time. This method has made the operation more flexible and time saving. The filling and capping operations are controlled using Programmable Logic Controllers (PLC, as the PLC’s are very much user-efficient, cost-effective and easy to control. By using PLC automation the whole process is kept under control. SCADA (Supervisory Control and Data Acquisition is used to monitor the process by means of a display system.

  18. PLC-based search and secure interlock system for the personnel safety in folded tandem ion accelerator

    Padmakumar, Sapna; Subramanyum, N.B.V.; Bhatt, Jignesh P.; Ware, Shailaja V.; Kansara, M.J.; Gupta, S.K.; Singh, P.

    2006-01-01

    Safety of the personnel is one of the key issues addressed in any accelerator project. The FOTIA facility at BARC is capable of operating under standard operation conditions without any radiation hazard. Even then for a safe and reliable operation of FOTIA a PLC (Programmable logic controller) based interlock system has been implemented. This interlocking system is compact, modular, flexible, robust and easy for troubleshooting. These advantages led to the popularity of PLC rather than using a relay-based system. This paper highlights the salient features of the search and secure interlock for the personal safety of FOTIA. (author)

  19. Sequence variation in the alpha-toxin encoding plc gene of Clostridium perfringens strains isolated from diseased and healthy chickens

    Abildgaard, L; Engberg, RM; Pedersen, Karl

    2009-01-01

    The aim of the present study was to analyse the genetic diversity of the alpha-toxin encoding plc gene and the variation in a-toxin production of Clostridium perfringens type A strains isolated from presumably healthy chickens and chickens suffering from either necrotic enteritis (NE) or cholangio......-hepatitis. The a-toxin encoding plc genes from 60 different pulsed-field gel electrophoresis (PFGE) types (strains) of C perfringens were sequenced and translated in silico to amino acid sequences and the a-toxin production was investigated in batch cultures of 45 of the strains using an enzyme...

  20. 75 FR 61363 - Airworthiness Directives; Rolls-Royce plc RB211-524 Series, -535 Series, RB211 Trent 700 Series...

    2010-10-05

    ...-0993; Directorate Identifier 2010-NE-08-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc... Federal holidays. Fax: (202) 493-2251. Contact Rolls-Royce plc, P.O. Box 31, Derby, DE24 8BJ, United... based on those comments. We will post all comments we receive, without change, to http://www.regulations...

  1. 75 FR 33738 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-524 Series and RB211 Trent 500, 700, and 800...

    2010-06-15

    ...-0562; Directorate Identifier 2009-NE-29-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR...-2251. Contact Rolls-Royce plc, P.O. Box 31, Derby, DE24 8BJ, United Kingdom; phone: 011 44 1332 242424... amend this proposed AD based on those comments. We will post all comments we receive, without change, to...

  2. 75 FR 27964 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-22B and RB211-524 Series Turbofan Engines

    2010-05-19

    ...-1157; Directorate Identifier 2009-NE-26-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR... p.m., Monday through Friday, except Federal holidays. Fax: (202) 493-2251. Contact Rolls-Royce plc... received by the closing date and may amend this proposed AD based on those comments. We will post all...

  3. INHIBITION OF GAP JUNCTIONAL INTERCELLULAR COMMUNICATION BY PERFLUORINATED COMPOUNDS IN RAT LIVER AND DOLPHIN KIDNEY EPITHELIAL CELL LINES IN VITRO AND SPRAGUE-DAWLEY RATS IN VIVO

    Abstract Gap Junctional Intercellular Communication (GJIC) is the major pathway of intercellular signal transduction, and is, thus, important for normal cell growth and function. Recent studies have revealed a global distribution of some perfluorinated organic compounds e...

  4. Different Expression and Localization of Phosphoinositide Specific Phospholipases C in Human Osteoblasts, Osteosarcoma Cell Lines, Ewing Sarcoma and Synovial Sarcoma

    V.Vasco

    2017-06-01

    Full Text Available Background: Bone hardness and strength depends on mineralization, which involves a complex process in which calcium phosphate, produced by bone-forming cells, was shed around the fibrous matrix. This process is strictly regulated, and a number of signal transduction systems were interested in calcium metabolism, such as the phosphoinositide (PI pathway and related phospholipase C (PLC enzymes. Objectives: Our aim was to search for common patterns of expression in osteoblasts, as well as in ES and SS. Methods: We analysed the PLC enzymes in human osteoblasts and osteosarcoma cell lines MG-63 and SaOS-2. We compared the obtained results to the expression of PLCs in samples of patients affected with Ewing sarcoma (ES and synovial sarcoma (SS. Results: In osteoblasts, MG-63 cells and SaOS-2 significant differences were identified in the expression of PLC δ4 and PLC η subfamily isoforms. Differences were also identified regarding the expression of PLCs in ES and SS. Most ES and SS did not express PLCB1, which was expressed in most osteoblasts, MG-63 and SaOS-2 cells. Conversely, PLCB2, unexpressed in the cell lines, was expressed in some ES and SS. However, PLCH1 was expressed in SaOS-2 and inconstantly expressed in osteoblasts, while it was expressed in ES and unexpressed in SS. The most relevant difference observed in ES compared to SS regarded PLC ε and PLC η isoforms. Conclusion: MG-63 and SaOS-2 osteosarcoma cell lines might represent an inappropriate experimental model for studies about the analysis of signal transduction in osteoblasts

  5. Analysis of Information Leakages on Laser Printers in the Media of Electromagnetic Radiation and Line Conductions

    Ulaş, Cihan

    2016-01-01

    In this paper, the emissions of a laser printer, which may process classified information, are investigated in the media of electromagnetic radiation (ER), Power Line Conductors (PLC), and Signal Line Conductors (SLC). First, the candidate frequency points of CE are examined in the frequency domain. Second, the emitted signal is AM-demodulated with the proper bandwidth, and then sampled by a high storage oscilloscope in these frequency points. Third, the collected data is converted to 2D imag...

  6. Digital communication system

    Monford, L. G., Jr. (Inventor)

    1974-01-01

    A digital communication system is reported for parallel operation of 16 or more transceiver units with the use of only four interconnecting wires. A remote synchronization circuit produces unit address control words sequentially in data frames of 16 words. Means are provided in each transceiver unit to decode calling signals and to transmit calling and data signals. The transceivers communicate with each other over one data line. The synchronization unit communicates the address control information to the transceiver units over an address line and further provides the timing information over a clock line. A reference voltage level or ground line completes the interconnecting four wire hookup.

  7. IBM 3705 Communications Controller

    1972-01-01

    The IBM 3705 Communications Controller is a simple computer which attaches to an IBM System/360 or System/370. Its purpose is to connect communication lines to the mainframe channel. It was a first communications controller of the popular IBM 37xx series.

  8. The Cish SH2 domain is essential for PLC-γ1 regulation in TCR stimulated CD8+ T cells.

    Guittard, Geoffrey; Dios-Esponera, Ana; Palmer, Douglas C; Akpan, Itoro; Barr, Valarie A; Manna, Asit; Restifo, Nicholas P; Samelson, Lawrence E

    2018-03-28

    Cish, participates within a multi-molecular E3 ubiquitin ligase complex, which ubiquitinates target proteins. It has an inhibitory effect on T cell activation mediated by PLC-γ1 regulation, and it functions as a potent checkpoint in CD8 + T cell tumor immunotherapy. To study the structural and functional relationships between Cish and PLC-γ1 during CD8 + T cell activation, we tested mutants of the Cish-SH2 (R107K) and D/BC (L222Q, C226Q) domains. We confirmed that Cish-SH2-specific binding was essential for PLC-γ1 ubiquitination and degradation. This domain was essential for the Cish-mediated inhibition of Ca 2+ release upon TCR stimulation. No effect on inhibition of cytokine release was observed with SH2 or D/BC mutants, although the absence of Cish led to an increased release of IFN-γ and TNF-α. Using imaging we showed that Cish was expressed mostly in the cytoplasm and we did not see any Cish clustering at the plasma membrane upon stimulation. We conclude that the Cish-SH2 domain is essential for PLC-γ1 regulation in TCR-stimulated CD8 + T cells.

  9. 75 FR 27973 - Airworthiness Directives; Rolls-Royce plc RB211-524C2 Series Turbofan Engines

    2010-05-19

    ... RB211-524C2 Series Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice... Rolls-Royce plc (RR) model RB211-524C2-19 and RB211-524C2-B-19 turbofan engines. These engines are...

  10. Design and application of the high-voltage DC power-supply control system based on PLC

    Huang Yiyun; Zheng Guanghua; Wu Junshuan; Yang Chunsheng; Hu Huaichuan

    2002-03-01

    The design and application of A kind of high-voltage DC power-supply control system based on PLC is referred, in addition, KingView is used to monitor the system in real time and manage the man-machine conversation ideally

  11. 78 FR 23316 - The Royal Bank of Scotland plc, et al.; Notice of Application and Temporary Order

    2013-04-18

    ... plc, et al.; Notice of Application and Temporary Order April 12, 2013. AGENCY: Securities and Exchange Commission (``Commission''). ACTION: Temporary order and notice of application for a permanent order under... application for a permanent order. Applicants have also applied for a permanent order. APPLICANTS: The Royal...

  12. 75 FR 58290 - Airworthiness Directives; Rolls-Royce plc RB211 Trent 700 and Trent 800 Series Turbofan Engines

    2010-09-24

    ... Airworthiness Directives; Rolls-Royce plc RB211 Trent 700 and Trent 800 Series Turbofan Engines AGENCY: Federal... or increase the scope of the AD. Costs of Compliance Based on the service information, we estimate.... Required parts would cost about $15,000 per product. Based on these figures, we estimate the cost of the AD...

  13. 75 FR 50877 - Airworthiness Directives; Rolls-Royce plc RB211-524C2 Series Turbofan Engines

    2010-08-18

    ... Airworthiness Directives; Rolls-Royce plc RB211-524C2 Series Turbofan Engines AGENCY: Federal Aviation... require adopting the AD as proposed. Costs of Compliance Based on the service information, we estimate.... Required parts will cost about $25,000 per product. Based on these figures, we estimate the cost of the AD...

  14. 75 FR 28655 - Rexam Closure Systems, Inc. a Subsidiary of Rexam PLC Including On-Site Leased Workers From...

    2010-05-21

    ... Hamlet, NC; Amended Certification Regarding Eligibility To Apply for Worker Adjustment Assistance In..., applicable to the workers of Rexam Closure Systems, Inc., a subsidiary of Rexam PLC, Hamlet, North Carolina... paid through Owens Illinois Manufacturing, Hamlet, North Carolina, who became totally or partially...

  15. MHC class I signaling in T cells leads to tyrosine kinase activity and PLC-gamma 1 phosphorylation

    Skov, S; Odum, Niels; Claesson, M H

    1995-01-01

    phosphorylation and the subsequent calcium response. The early tyrosine kinase activity was found to be dependent on expression of the TCR/CD3 complex and the CD45 molecule on the surface of the T cells. Furthermore, MHC-I cross-linking was shown to tyrosine phosphorylate PLC-gamma 1 (phospholipase C-gamma 1...

  16. The new control system of HLS linac and transport line

    Liu Gongfa; Li Weimin; Li Jingyi; Li Chuan; Cheng Liping; Bao Xun; Wang Jigang; Xuan Ke

    2005-01-01

    The new linac and transport line control system of Hefei Light Source (HLS) is a distributed control system based on EPICS (Experimental Physics and Industrial Control System). Industrial PC (IPC) is widely used as not only Input/Output Controller (IOC) but also device controller. Besides industrial PC, PLC and microcontroller are also used as device controllers. The software for industrial PC based device controller is developed based on VxWorks real-time operating system. The software for PLC and microcontroller are written with ladder software package and assemble language, respectively. PC with Linux and SUN workstation with Solaris are used as operator interfaces (OPI). High level control is made up of some EPICS tools and Tcl/Tk scripts. (authors)

  17. Decommissioning of the gaseous diffusion plant at BNF plc Capenhurst in the UK

    Clements, D.W.; Cross, J.R.

    1993-01-01

    Since 1982, a gaseous diffusion plant located at the British Nuclear Fuels plc (BNFL) site at Capenhurst in the United Kingdom, has been undergoing decontamination, decommissioning, and dismantling. By March 1994, the decontamination and decommissioning activities will be complete with 99% of the materials used to construct the plant recycled to the environment as clean material. This paper describes the history of the decontamination, decommissioning, dismantling, and disposal program. Reference is made to the scale of the project and to the special techniques developed, particularly in the areas of size reduction, decontamination, and protection of personnel and the environment. The quantities of material involved that require decontamination and release levels for recycling materials in the U.K. metals market are discussed

  18. On the determination of the colour term in the P-L-C relation for cepheids

    Feast, M.W.; Balona, L.A.

    1980-01-01

    Recent speculations that the coefficient of the colour term in the P-L-C relation for cepheids may be considerably different from 2.7 are inconsistent with existing data on LMC cepheids. The colour coefficient recently derived is not significantly affected by taking into account an absorption induced correlation between the errors in 0 > and ( 0 > - 0 >). The computer simulation which shows the bias introduced in the colour coefficient when this is derived by an inappropriate method (simple least squares) is consistent with theory and in accord with actual results in the LMC. This gives added confidence in the unbiased nature of the results derived by a maximum likelihood method which takes into account errors in each variable. (author)

  19. Design of Measurement and Control System of Composite Fast Transfer Switch Based on PLC

    ZHANG Hong-yi

    2017-06-01

    Full Text Available The fast transfer switch gets more extensive application in the power supply system along with the raising of power supply requirement for continuity and reliability in the sensitivity loads such as in airport,military place,hospital and large scale industrial production line. Therefore it is important that how to make fast transfer switch run safely and reliably. The paper expatiated the structure and principle of a fast transfer switch based on mechanical and electronic compound technology,and,according to the basic requirement and the characteristic of the fast transfer switch,a PLC mastered measuring and controlling system has been designed to raise the operation reliability of the fast transfer switch.

  20. The PLC-based Industrial Temperature Control System: Design and Implementation

    Wei Fanjie

    2017-01-01

    Full Text Available Targeting at the problem of slow response and low accuracy of the automatic temperature control system for material processing and boiler heating, a new design method is proposed to work with the PLC-based temperature control system, where the box temperature control may be achieved through the fan and the heating plate. The hardware design and software design of the system are analyzed in detail. In this paper, a combination of the traditional PID control and the more popular fuzzy control is taken as the control program to achieve the overall design of the control algorithm. Followed by the simulation in the MATLAB software, the designed system is highlighted by its the characteristics of impressive stability, precision and robustness.

  1. A Component-Based Modeling and Validation Method for PLC Systems

    Rui Wang

    2014-05-01

    Full Text Available Programmable logic controllers (PLCs are complex embedded systems that are widely used in industry. This paper presents a component-based modeling and validation method for PLC systems using the behavior-interaction-priority (BIP framework. We designed a general system architecture and a component library for a type of device control system. The control software and hardware of the environment were all modeled as BIP components. System requirements were formalized as monitors. Simulation was carried out to validate the system model. A realistic example from industry of the gates control system was employed to illustrate our strategies. We found a couple of design errors during the simulation, which helped us to improve the dependability of the original systems. The results of experiment demonstrated the effectiveness of our approach.

  2. STS-55 MS1/PLC Ross monitors Payload Specialist Walter's Anthrorack activity

    1993-01-01

    STS-55 German Payload Specialist 1 Ulrich Walter breathes into Rack 9 Anthrorack (AR) (Human Physiology Laboratory) device for Pulmonary Perfusion and Ventilation During Rest and Exercise experiment while working inside the Spacelab Deutsche 2 (SL-D2) science module aboard the Earth-orbiting Columbia, Orbiter Vehicle (OV) 102. Seated on the bicycle ergometer, Walter utilizes the respiratory monitoring system, part of a broad battery of experiments designed to investigate human physiology under microgravity conditions. In the background, Mission Specialist 1 (MS1) and Payload Commander (PLC) Jerry L. Ross monitors Walter's activity. Walter represents the German Aerospace Research Establishment (DLR) on the 10-day SL-D2 mission. Visible on the aft end cone are a fire extinguisher and the Crew Telesupport Experiment (CTE) Macintosh portable computer mounted on an adjustable work platform.

  3. Comparative diagnostic efficacy of recombinant LLO and PI-PLC-based ELISAs for detection of listeriosis in animals.

    Suryawanshi, Rahul D; Malik, Satya Veer Singh; Jayarao, Bhushan; Chaudhari, Sandeep P; Savage, Emily; Vergis, Jess; Kurkure, Nitin V; Barbuddhe, Sukhadeo B; Rawool, Deepak B

    2017-06-01

    The present study for the first time evaluates the serodiagnostic efficacy of two recombinant antigens namely, listeriolysin O (rLLO) and phosphatidyl-inositol phospholipase C (rPI-PLC). Indirect ELISA with the above recombinant antigens was used on samples collected from bovines (n=106), goats (n=138) and pigs (n=92) having either a history of abortion, emaciation and/or apparently healthy animals. Isolation of Listeria was attempted from the blood samples using USDA-FSIS method. On screening of test sera by rLLO-based ELISA, antibodies against anti-listeriolysin O (ALLO) were observed in goats (22.46%), bovines (15.10%) and pigs (16.31%). As advocated, after adsorption of positive serum samples with streptolysin O (SLO), the seropositivity for ALLO was marginally reduced (p>0.05) in goats (21.73%) and bovines (10.38%), whereas, in pigs the reduction (5.43%) was significant (pPLC-based ELISA revealed higher non-specific seropositivity for antilisterial antibodies in goats (45.65%), bovines (31.13%) and pigs (8.69%). Further, on comparing the seropositivity with isolation rate, of the 16 animals that were culturally-positive for L. monocytogenes, 15 showed ALLO positivity in unadsorbed as well as SLO-adsorbed sera by rLLO-based ELISA, however, rPI-PLC-based ELISA could detect seropositivity in only 5 animals. Moreover, rPI-PLC-based ELISA also showed seropositivity in those animals (7/30) that were culturally positive for other Listeria spp. In conclusion, rLLO can serve as a better antigen than rPI-PLC in ELISA for the serodiagnosis of listeriosis in animals; however, prior adsorption of test sera with SLO is required to avoid false positive results. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Pancreatic acini possess endothelin receptors whose internalization is regulated by PLC-activating agents.

    Hildebrand, P; Mrozinski, J E; Mantey, S A; Patto, R J; Jensen, R T

    1993-05-01

    Endothelin-1 (ET-1) and ET-3 mRNA have been found in the pancreas. We investigated the ability of ET-1, ET-2, and ET-3 to interact with and alter dispersed rat pancreatic acinar cell function. Radiolabeled ETs bound in a time- and temperature-dependent fashion, which was specific and saturable. Analysis demonstrated two classes of receptors, one class (ETA receptor) had a high affinity for ET-1 but a low affinity for ET-3, and the other class (ETB receptor) had equally high affinities for ET-1 and ET-3. No specific receptor for ET-2 was identified. Pancreatic secretagogues that activate phospholipase C (PLC) inhibited binding of 125I-labeled ET-1 (125I-ET-1) or 125I-ET-3, whereas agents that act through adenosine 3',5'-cyclic monophosphate (cAMP) did not. A23187 had no effect on 125I-ET-1 or 125I-ET-3 binding, whereas the phorbol ester 12-O-tetradecanoylphorbol 13-acetate reduced binding. The effect of cholecystokinin octapeptide (CCK-8) was mediated through its own receptor. Stripping of surface bound ligand studies demonstrated that both 125I-labeled ET-1 and 125I-labeled ET-3 were rapidly internalized. CCK-8 decreased the internalization but did not change the amount of surface bound ligand. Endothelins neither stimulate nor alter changes in enzyme secretion, intracellular calcium, cAMP, or [3H]inositol trisphosphate (IP3). This study demonstrates the presence of ETA and ETB receptors on rat pancreatic acini; occupation of both receptors resulted in rapid internalization, which is regulated by PLC-activating secretagogues. Occupation of either ET receptor did not alter intracellular calcium, cAMP, IP3, or stimulate amylase release.

  5. RISK COMMUNICATION FOR ES&H PROFESSIONALS AND LINE SUPERVISORS PARTICIPANT MANUAL COURSE NUMBER 004111 REV 0.1 JULY 2011

    ALDRIDGE PK; ROCKS S

    2011-08-11

    This course will help you successfully apply risk communication principles when interacting with workers regarding work hazards. What Is the Difference Between a Risk and a Hazard? In many cases, the terms 'risk' and 'hazard' are incorrectly used interchangeably. A hazard is a physical condition or practice with the potential for causing harm/adverse effects. A risk is the probability of harm/adverse effects occurring from an exposure to a hazard. It is modified by the severity of harm (the consequence). Once a hazard is identified, a risk assessment is conducted to determine the severity of the risk. It uses scientific methods and rigorous tests to determine the effects of the risk on people and the environment. Risk Management takes data from the risk assessment and writes policies to help protect people and the environment against the risk. Risk communication is an ongoing process that starts soon after a hazard is identified and continues through the writing of policies. In the past, governing agencies did not do a good job of communicating risk; they would only communicate about risk after studies had been conducted and policies written.

  6. WP EMPLACEMENT CONTROL AND COMMUNICATION EQUIPMENT DESCRIPTIONS

    Raczka, N.T.

    1997-01-01

    The objective and scope of this document are to list and briefly describe the major control and communication equipment necessary for waste package emplacement at the proposed nuclear waste repository at Yucca Mountain. Primary performance characteristics and some specialized design features of the required equipment are explained and summarized in the individual subsections of this document. This task was evaluated in accordance with QAP-2-0 and found not to be quality affecting. Therefore, this document was prepared in accordance with NAP-MG-012. The following control and communication equipment are addressed in this document: (1) Programmable Logic Controllers (PLC's); (2) Leaky Feeder Radio Frequency Communication Equipment; (3) Slotted Microwave guide Communication Equipment; (4) Vision Systems; (5) Radio Control Equipment; and (6) Enclosure Cooling Systems

  7. In-Containment Signal Conditioning and Transmission via Power Lines within High Dose Rate Areas of Nuclear Power Plants

    Mueller, Steffen; Weigel, Robert; Koelpin, Alexander [Institute for Electronics Engineering, University of Erlangen-Nuremberg, Cauerstr. 9, 91058 Erlangen (Germany); Dennerlein, Juergen; Janke, Iryna; Weber, Johannes [AREVA GmbH, Paul-Gossen-Str. 100, 91052 Erlangen (Germany)

    2015-07-01

    Signal conditioning and transmission for sensor systems and networks within the containment of nuclear power plants (NPPs) still poses a challenge to engineers, particularly in the case of equipment upgrades for existing plants, temporary measurements, decommissioning of plants, but also for new builds. This paper presents an innovative method for efficient and cost-effective instrumentation within high dose rate areas inside the containment. A transmitter-receiver topology is proposed that allows simultaneous, unidirectional point-to-point transmission of multiple sensor signals by superimposing them on existing AC or DC power supply cables using power line communication (PLC) technology. Thereby the need for costly installation of additional cables and containment penetrations is eliminated. Based on commercial off-the-shelf (COTS) electronic parts, a radiation hard transmitter is designed to operate in harsh environment within the containment during full plant operation. Hardware modularity of the transmitter allows application specific tradeoffs between redundancy and channel bandwidth. At receiver side in non-radiated areas, signals are extracted from the power line, demodulated, and provided either in analog or digital output format. Laboratory qualification tests and field test results within a boiling water reactor (BWR) are validating the proof of concept of the proposed system. (authors)

  8. Designing of Simulation for Engine Room Km. Sinabung with Control Monitoring Web Server Based by Wireless Network and Power Line Communication

    Hadi, Eko Sasmito; Adietya, Berlian Arswendo; S.P, Firdaus

    2013-01-01

    Engine room monitoring control system is monitoring and controlling main engine and auxiliary engine from long distance by powerline communication network and wireless network to ease the operator in operating the ship and save operational cost. To prevent error in programming the main engine and auxiliary engine, a simulation using instrument software is needed to know the machine characteristic. After simulation result fulfills the requirement which is approached the value of test record, i...

  9. DESIGNING OF SIMULATION FOR ENGINE ROOM KM. SINABUNG WITH CONTROL MONITORING WEB SERVER BASED BY WIRELESS NETWORK AND POWER LINE COMMUNICATION

    Eko Sasmito Hadi; Berlian Arswendo Adietya; Firdaus S.P

    2013-01-01

    Engine room monitoring control system is monitoring and controlling main engine and auxiliary engine from long distance by powerline communication network and wireless network to ease the operator in operating the ship and save operational cost. To prevent error in programming the main engine and auxiliary engine, a simulation using instrument software is needed to know the machine characteristic. After simulation result fulfills the requirement which is approached the value of test record, i...

  10. Safety rule of the KTA. Alarm system, staff locator systems, and internal and external communication lines of nuclear power plants. Pt. 1

    1977-01-01

    This rule aims at stipulating the requirements on type and extent of communication means for personnel within the nuclear power plant, and from the nuclear power plant to the outside. Requirements on design, construction, operating equipment, and alarm and locator system tests for nuclear power plants are defined. The rule applies to stationary nuclear power plants with one power station unit, but not to facilities of process control, radiation protection control, fire protection control, environmental control, and plant security. (orig./HP) [de

  11. Conference Session I: Mitigating Risk at the Front Lines: The Copyright First Responders Program. Presented by Kyle Courtney, Copyright Advisor, the Office for Scholarly Communication, Harvard University.

    Sara R. Benson

    2018-02-01

    Full Text Available This is a summary of Kyle Courtney's Invited Presentation at the 2017 Kraemer Copyright Conference titled "Mitigating Risk at the Front Lines:  The Copyright First Responders Program."  After reading this article you will better understand the method and purpose of the First Responders Program and, hopefully, like me, you will be ready to volunteer your institution to add to the growing list of libraries engaged in this hub-and-spoke model of copyright information system.

  12. Serial interprocessor communications system

    Labiak, W.; Siemens, P.; Bailey, C.

    1980-01-01

    A serial communications system based on the EIA RS232-C standard with modem control lines has been developed. The DLV11-E interface is used for this purpose. All handshaking is done with the modem control lines. This allows totally independent full duplex communication. The message format consists of eight bit data with odd parity and a sixteen bit checksum on the whole message. All communications are fully interrupt driven. A program was written to load a program into a remote LSI-11 using the serial line without bootstrap ROM

  13. Wire communication engineering

    Son, Byeong Tae

    1997-02-01

    This book describes wire telecommunication engineering/ It is divided into eleven chapter, which deal with Introduction with development of telecommunication, voice and sound wave and communication network, Telegraphy with summary of telegraphy, code of telegraphy, communication speed, morse and telex, Telephone on structure, circuit and image telephone, Traffic on telecommunication traffic, transmission of line about theory, cable line and loaded cable, carrier communication with carrier telegraphy and carrier telephone, optical communication with types, structure, specialty, laser and equipment, DATA, Mobile telecommunication on summary, mobile telephone, radio paging and digital mobile telecommunication, ISDN with channel of ISDN, and service of ISDN, and design of telecommunication.

  14. Activation of PLC by an endogenous cytokine (GBP) in Drosophila S3 cells and its application as a model for studying inositol phosphate signalling through ITPK1.

    Zhou, Yixing; Wu, Shilan; Wang, Huanchen; Hayakawa, Yoichi; Bird, Gary S; Shears, Stephen B

    2012-12-01

    Using immortalized [3H]inositol-labelled S3 cells, we demonstrated in the present study that various elements of the inositol phosphate signalling cascade are recruited by a Drosophila homologue from a cytokine family of so-called GBPs (growth-blocking peptides). HPLC analysis revealed that dGBP (Drosophila GBP) elevated Ins(1,4,5)P3 levels 9-fold. By using fluorescent Ca2+ probes, we determined that dGBP initially mobilized Ca2+ from intracellular pools; the ensuing depletion of intracellular Ca2+ stores by dGBP subsequently activated a Ca2+ entry pathway. The addition of dsRNA (double-stranded RNA) to knock down expression of the Drosophila Ins(1,4,5)P3 receptor almost completely eliminated mobilization of intracellular Ca2+ stores by dGBP. Taken together, the results of the present study describe a classical activation of PLC (phospholipase C) by dGBP. The peptide also promoted increases in the levels of other inositol phosphates with signalling credentials: Ins(1,3,4,5)P4, Ins(1,4,5,6)P4 and Ins(1,3,4,5,6)P5. These results greatly expand the regulatory repertoire of the dGBP family, and also characterize S3 cells as a model for studying the regulation of inositol phosphate metabolism and signalling by endogenous cell-surface receptors. We therefore created a cell-line (S3ITPK1) in which heterologous expression of human ITPK (inositol tetrakisphosphate kinase) was controlled by an inducible metallothionein promoter. We found that dGBP-stimulated S3ITPK1 cells did not synthesize Ins(3,4,5,6)P4, contradicting a hypothesis that the PLC-coupled phosphotransferase activity of ITPK1 [Ins(1,3,4,5,6)P5+Ins(1,3,4)P3→Ins(3,4,5,6)P4+Ins(1,3,4,6)P4] is driven solely by the laws of mass action [Chamberlain, Qian, Stiles, Cho, Jones, Lesley, Grabau, Shears and Spraggon (2007) J. Biol. Chem. 282, 28117-28125]. This conclusion represents a fundamental breach in our understanding of ITPK1 signalling.

  15. 76 FR 24793 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-524 Series and RB211 Trent 500, 700, and 800...

    2011-05-03

    ... Airworthiness Directives; Rolls-Royce plc (RR) RB211-524 Series and RB211 Trent 500, 700, and 800 Series... the AD. Costs of Compliance Based on the service information, we estimate that this AD would affect...

  16. Dynamics of plc gene transcription and α-toxin production during growth of Clostridium perfringens strains with contrasting α-toxin production

    Abildgaard, Lone; Schramm, Andreas; Rudi, Knut

    2009-01-01

    The aim of the present study was to investigate transcription dynamics of the α-toxin-encoding plc gene relative to two housekeeping genes (gyrA and rplL) in batch cultures of three Clostridium perfringens strains with low, intermediate, and high levels of α-toxin production, respectively. The plc...... transcript level was always low in the low α-toxin producing strain. For the two other strains, plc transcription showed an inducible pattern and reached a maximum level in the late exponential growth phase. The transcription levels were however inversely correlated to α-toxin production for the two strains....... We propose that this discrepancy is due to differences in plc translation rates between the strains and that strain-specific translational rates therefore must be determined before α-toxin production can be extrapolated from transcript levels in C. perfringens....

  17. Study on the Development of Builtin PLC%内嵌式PLC的设计与实现

    刘家亮; 熊晓红; 黄树槐

    2001-01-01

    介绍了PLC编程语言——语句表的结构和特点,讨论了语句表解释程序的词法分析和语法分析技术,以及运用面向对象的编程思想、构造语句表解释程序,实现内嵌式PLC等问题。%In this thesis, the architecture and character of the PLC languageSTL are introduced. And then, the structure of STL interpreting program and the technique of lexical analysis and syntax analysis are discussed. Develop the STL interpreting program with the idea of OOP(objectoriented programming), realized the builtin PLC are also attempted.

  18. Měření výpočetního výkonu PLC PFC200

    Majchrák, František

    2017-01-01

    V práci sa analyzujú možnosti merania výpočetného výkonu PLC PFC200 od firmy WAGO. Prvú časť práce venujem priblíženiu funkčnosti automatu, jeho využitiu, jednotlivým možnostiam programovania, zoznamujem sa s implementáciou vlastných programových blokov v prostredí embedded Linux a zisťujem jeho prepojenie s PLC prostredím. V druhej časti práce sa sústredím na meranie výkonu, jeho typy, popis certifikovaných meraní a jeho celkové zhodnotenie. V poslednej časti je vysvetlená aplikácia, ktorá z...

  19. Experience on the FMS Communication module Development for an Application to Safety- Critical Communication Network

    Son, Kwang Seop; Lee, Jang Soo; Kim, Jung Heon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2009-05-15

    The field bus has been developed for a network system which supports the real-time communication of various controls and automation equipment. It is known for Profibus in the field of a production automation environment. The Profibus standard uses open communication based on the ISO/OSI model. The Probibus standard uses layer 1, layer 2, layer 7. Layer 7 of Probibus FMS(Fieldbus Message Specification) provides a information and the user of a station. The high-level communication of the safety-grade PLC (POSAFE-Q) developed through the KNICS(Korea Nuclear I and C System) project is the FMS This paper describes the design, the configuration, and the test method of the FMS communication module.

  20. Experience on the FMS Communication module Development for an Application to Safety- Critical Communication Network

    Son, Kwang Seop; Lee, Jang Soo; Kim, Jung Heon

    2009-01-01

    The field bus has been developed for a network system which supports the real-time communication of various controls and automation equipment. It is known for Profibus in the field of a production automation environment. The Profibus standard uses open communication based on the ISO/OSI model. The Probibus standard uses layer 1, layer 2, layer 7. Layer 7 of Probibus FMS(Fieldbus Message Specification) provides a information and the user of a station. The high-level communication of the safety-grade PLC (POSAFE-Q) developed through the KNICS(Korea Nuclear I and C System) project is the FMS This paper describes the design, the configuration, and the test method of the FMS communication module