WorldWideScience

Sample records for line carrier plc

  1. Power Line Communication (PLC) in Space - Current Status and Outlook

    Wolf, J.

    2012-05-01

    The Power Line Communication (PLC) technology as known from various terrestrial applications, e.g. in building automation, in the automotive sector and on aircraft, appears to be a promising technology for the use on spacecraft. Starting from a critical overview on existing terrestrial PLC applications with their pros and cons, the paper gives a motivation for the introduction of the PLC technology on spacecraft, discusses the potential areas where it can be applied and is highlighting the potential problem areas. A short overview of on-going ESA PLC activities is provided and an outlook is given.

  2. Basic Stand Alone Carrier Line Items PUF

    U.S. Department of Health & Human Services — This release contains the Basic Stand Alone (BSA) Carrier Line Items Public Use Files (PUF) with information from Medicare Carrier claims. The CMS BSA Carrier Line...

  3. PLC Programming

    Lee, Seong Jae; Wi, Seong Dong; Yoo, Jong Seon; Kim, Se Chan

    2001-02-01

    This book tells of PLC programming for KGL-WIN with summary of PLC, performance and function of PLC like characteristic of KGL-WIN, connection method with PLC, basic performance of K200S/K300S/K1000S, diagram of input and output H/W, writing project, staring the program, editing of program, on-line function, debugging and instructions like control, timer and counter, data transmission, comparison, rotation and moving, system, data operating data conversion and application program.

  4. Performance analysis of the PLC (Power Line Communication) in medium voltage electrical networks; Analise de desempenho de sistemas PLC em redes eletricas de media tensao

    Mota, A.A.; Paleta, R. [Pontificia Universidade Catolica de Campinas (PUC-Campinas), SP (Brazil)], E-mail: amota@puc-campinas.edu.br; Mota, L.T.M.; Ricardo, R.A. [Indelmatec Engenharia, Campinas, SP (Brazil)], E-mail: mota@indelmatec.com.br

    2009-07-01

    Nowadays, the information access in communication networks is widely explored due to the increase of Internet users. In this context, the PLC (Power Line Communication) technology is an alternative for data transmission. This technology is based on the usage of transmission/distribution power lines for data transmission. However there are some problems related to the usage of this technology: adequate data transmission rates and generation of acceptable levels of electromagnetic interference (EMI). This work had the objective of studying the performance of PLC systems in medium voltage electrical networks, through the assess of data transmission rates and the generated EMI. Tests were carried out in a test field that corresponded to a medium voltage electrical network and the obtained results show that, under some circumstances, the PLC system does not reach the existent technical recommendations. (author)

  5. MCD 80: A modular coupling system for power line carrier transmission

    Fischer, B; Mayer, M

    1983-05-01

    Power line carrier (PLC) links are of great importance to power supply utilities. The communications equipment is linked to the H.V. system by a coupling device. Brown Boveri have developed a new modular coupling system MCD 80 which is compact, programmable and economical. The benefit of years of experience in the field went into its development. With the new system, optimum PLC couplings, R.F. through-connections and junction networks are possible for all H.V. transmission systems. A general look at the subject of PLC couplings is followed by a closer look at the main components, such as the programmable high pass coupling unit, band pass coupling unit, hybrid, separating filter, R.F. junction network and attenuator. Some typical examples are described.

  6. Design of Control System for Flexible Packaging Bags Palletizing Production Line Based on PLC

    Zheng, Huiping; Chen, Lin; Zhao, Xiaoming; Liu, Zhanyang

    Flexible packaging bags palletizing production line is to put the bags in the required area according to particular order and size, in order to finish handling, storage, loading and unloading, transportation and other logistics work of goods. Flexible packaging bags palletizing line is composed of turning bags mechanism, shaping mechanism, indexing mechanism, marshalling mechanism, pushing bags mechanism, pressing bags mechanism, laminating mechanism, elevator, tray warehouse, tray conveyor and loaded tray conveyor. Whether the whole production line can smoothly run depends on each of the above equipment and precision control among them. In this paper the technological process and the control logic of flexible packaging bags palletizing production line is introduced. Palletizing process of the production line realized automation by means of a control system based on programmable logic controller (PLC). It has the advantages of simple structure, reliable and easy maintenance etc.

  7. Inhibitory effect of genistein on PLC/PRF5 hepatocellular carcinoma cell line

    Mehdi Nikbakht Dastjerdi

    2015-01-01

    Full Text Available Background: Natural compounds including flavonoids like genistein (GE are able to inhibit cell proliferation and induce apoptosis. GE is the main representative of these groups. GE inhibits carcinogenic tumors such as colon, stomach, lung, and pancreas tumors. The aim of the present study was to analyze the apoptotic effect of GE in the hepatocellular carcinoma (HCC PLC/PRF5 cell line. Methods: Cells were treated with various doses of GE (1, 5, 10, 25, 50, 75, and 100 μM/L at different times (24, 48, and 72 h and the MTT assay was commonly used. Furthermore, cells were treated with single dose of GE (25 μM at different times and flow cytometry was performed. Results: GE inhibited the growth of liver cancer cells significantly with a time- and dose-dependent manner. The percentage of living cells in GE treatment groups with a concentration of 25 μM at different times were 53, 48 and 47%, respectively (P < 0.001. Result of flow cytometry demonstrated that GE at a 25 μM concentration induces apoptosis significantly in a time-dependent manner. The percentage of apoptotic cells at different times were 44, 56, and 60%, respectively (P < 0.001. Conclusions: GE can significantly inhibit the growth of HCC cells and plays a significant role in apoptosis of this cell line.

  8. Effects of 5-fluorouracil on biological characteristics and drug resistance mechanisms of liver cancer cell line PLC/RAF/5

    CHENG Kangwen

    2015-09-01

    Full Text Available ObjectiveTo study the changes in biological characteristics of a liver cancer cell line PLC/RAF/5 after repeated exposure to a chemotherapy drug, 5-fluorouraci (5-FU, and to investigate the relationship between drug-resistant liver cancer cells and liver cancer stem cells. MethodsA low concentration of 5-FU (1 μg/ml was used to treat the human liver cancer cell line PLC/RAF/5 repeatedly to establish the PLC/RAF/5/5-FU cell line. Morphological differences between the two types of cells were observed. The inhibitory effects of different concentrations of 5-FU (0, 0.25, 0.5, 1, 1.5, and 2 μg/ml on the proliferation of the two types of cells were determined using the CCK-8 assay. Apoptosis of the two types of cells after exposure to different concentrations of 5-FU (0.5, 1, and 2 μg/ml for 48 h was analyzed using flow cytometry. The proportions of side population cells in both types of cells were measured using flow cytometry. The colony-forming ability was compared between the two types of cells by the plate colony-forming assay. The expression of Bax, Bcl-2, ABCG2, and FoxM1 proteins in both types of cells was examined by Western blot. Between-group comparison was performed by t test. ResultsThe PLC/RAF/5/5-FU cell line was successfully established using the chemotherapy drug 5-FU. Compared with the PLC/RAF/5 cells, the PLC/RAF/5/5-FU cells had a larger volume, fewer protrusions, a changed shape of a long shuttle, and enhanced refractivity. Moreover, compared with the parent cells, the PLC/RAF/5/5-FU cells had a significantly lower sensitivity to the inhibitory effect of 5-FU on proliferation, a significantly lower proportion of cells at the G0/G1 phase of the cell cycle, significantly higher proportions of cells at the S and G2/M phases, significantly higher resistance to apoptosis, a significantly higher proportion of side population cells, and significantly enhanced proliferation (P<0.05. According to the results of Western blot assay, the

  9. A High-Speed Power-Line Communication System with Band-Limited OQAM Based Multi-Carrier Transmission

    Kawabata, Naohiro; Koga, Hisao; Muta, Osamu; Akaiwa, Yoshihiko

    As a method to realize a high-speed communication in the home network, the power-line communication (PLC) technique is known. A problem of PLC is that leakage radiation interferes with existing systems. When OFDM is used in a PLC system, the leakage radiation is not sufficiently reduced, even if the subcarriers corresponding to the frequency-band of the existing system are never used, because the signal is not strictly band-limited. To solve this problem, each subcarrier must be band-limited. In this paper, we apply the OQAM based multi-carrier transmission (OQAM-MCT) to a high-speed PLC system, where each subcarrier is individually band-limited. We also propose a pilot-symbol sequence suitable for frequency offset estimation, symbol-timing detection and channel estimation in the OQAM-MCT system. In this method, the pilot signal-sequence consists of a repeated series of the same data symbol. With this method, the pilot sequence approximately becomes equivalent to OFDM sequence and therefore existing pilot-assisted methods for OFDM are also applicable to OQAM-MCT system. Computer simulation results show that the OQAM-MCT system achieves both good transmission rate performance and low out-of-band radiation in PLC channels. It is also shown that the proposed pilot-sequence improves frequency offset estimation, symbol-timing detection and channel estimation performance as compared with the case of using pseudo-noise sequence.

  10. 78 FR 10172 - Lisa Anne Cornell and G. Ware Cornell, Jr. v. Princess Cruise Lines, Ltd. (Corp), Carnival PLC...

    2013-02-13

    ... laws of the United Kingdom which does business under the names of Cunard Line, P&O Cruises, and P&O Cruises Australia as a common carrier for hire of passengers from ports in the United States;'' and...

  11. Efficient Implementation of a Symbol Timing Estimator for Broadband PLC.

    Nombela, Francisco; García, Enrique; Mateos, Raúl; Hernández, Álvaro

    2015-08-21

    Broadband Power Line Communications (PLC) have taken advantage of the research advances in multi-carrier modulations to mitigate frequency selective fading, and their adoption opens up a myriad of applications in the field of sensory and automation systems, multimedia connectivity or smart spaces. Nonetheless, the use of these multi-carrier modulations, such as Wavelet-OFDM, requires a highly accurate symbol timing estimation for reliably recovering of transmitted data. Furthermore, the PLC channel presents some particularities that prevent the direct use of previous synchronization algorithms proposed in wireless communication systems. Therefore more research effort should be involved in the design and implementation of novel and robust synchronization algorithms for PLC, thus enabling real-time synchronization. This paper proposes a symbol timing estimator for broadband PLC based on cross-correlation with multilevel complementary sequences or Zadoff-Chu sequences and its efficient implementation in a FPGA; the obtained results show a 90% of success rate in symbol timing estimation for a certain PLC channel model and a reduced resource consumption for its implementation in a Xilinx Kyntex FPGA.

  12. Efficient Implementation of a Symbol Timing Estimator for Broadband PLC

    Francisco Nombela

    2015-08-01

    Full Text Available Broadband Power Line Communications (PLC have taken advantage of the research advances in multi-carrier modulations to mitigate frequency selective fading, and their adoption opens up a myriad of applications in the field of sensory and automation systems, multimedia connectivity or smart spaces. Nonetheless, the use of these multi-carrier modulations, such as Wavelet-OFDM, requires a highly accurate symbol timing estimation for reliably recovering of transmitted data. Furthermore, the PLC channel presents some particularities that prevent the direct use of previous synchronization algorithms proposed in wireless communication systems. Therefore more research effort should be involved in the design and implementation of novel and robust synchronization algorithms for PLC, thus enabling real-time synchronization. This paper proposes a symbol timing estimator for broadband PLC based on cross-correlation with multilevel complementary sequences or Zadoff-Chu sequences and its efficient implementation in a FPGA; the obtained results show a 90% of success rate in symbol timing estimation for a certain PLC channel model and a reduced resource consumption for its implementation in a Xilinx Kyntex FPGA.

  13. New Concept of PLC Modems: Multi-Carrier System for Frequency Selective Slow-Fading Channels Based on Layered SCCC Turbocodes

    J. Zavrtalek

    2015-09-01

    Full Text Available The article introduces a novel concept of a PLC modem as a complement to the existing G3 and PRIME standards for communications using medium- or high-voltage overhead or cable lines. The proposed concept is based on the fact that the levels of impulse noise and frequency selectivity are lower on high-voltage lines than on low-voltage ones. Also, the demands for “cost-effective” circuitry design are not so crucial as in the case of modems for low-voltage level. In contract to these positive conditions, however, there is the need to overcome much longer distances and to take into account low SNR on the receiving side. With respect to the listed reasons, our concept makes use of MCM, instead of OFDM. The assumption of low SNR is compensated through the use of an efficient channel coding based on a serially concatenated turbo code. In addition, MCM offers lower latency and PAPR compared to OFDM. Therefore, when using MCM, it is possible to excite the line with higher power. The proposed concept has been verified during experimental transmission of testing data over a real, 5 km long, 22kV overhead line.

  14. DISAIN SISTEM KENDALI MESIN AIR LEAK TEST MENGGUNAKAN SISTEM KENDALI PLC OMRON CJ2M DI HVAC (HEATING, VENTILATING, AND AIR CONDITIONING LINE 6

    Syahril Ardi

    2015-03-01

    Full Text Available Pada proses produksi pembuatan komponen HVAC (Heating, Ventilating, and Air Conditioning dari perusahaan manufaktur di Indonesia, memerlukan proses pengecekan kebocoran pada bagian HVAC. Proses pengecekan ini dilakukan untuk memastikan tidak ada komponen HVAC yang bocor sebelum dikirim ke pihak pelanggan. Penelitian ini dilakukan untuk membuat system dan alat air leak test. Mesin air leak test ini menggunakan prinsip kerja differential pressure air leak test, yaitu metode yang membandingkan antara tekanan udara yang diberikan ke produk dan master produk. Pada penelitian ini, kami membuat disain mesin air leak test menggunakan sistem kendali berupa air leak tester, PLC, dan HMI. Berdasarkan kondisi dengan kapasitas produksi yang meningkat karena bertambahnya permintaan dari customer, dapat ditanggulangi dengan adanya share loading produksi dari HVAC line 4 ke line baru, yaitu HVAC line 6. Hasil yang didapat dari pengujian deteksi kebocoran produk,didapat nilai parameter kebocoran produk sebesar 2.23 ml/min.

  15. Solucions PLC obertes

    López Llauradó, Oriol

    2006-01-01

    Treball que, després de revisar el concepte de PLC i d'exposar la necessitat de solucions obertes, defineix el concepte de PLC obert, basat en programari lliure i presenta alguns projectes interessants de PLC obert. Trabajo que, después de revisar el concepto de PLC y de exponer la necesidad de soluciones abiertas, define el concepto de PLC abierto, basado en el software libre y presenta algunos proyectos interesantes de PLC abierto. Study that, after looking at the concept of PLC and s...

  16. 47 CFR 69.608 - Carrier Common Line hypothetical net balance.

    2010-10-01

    ... 47 Telecommunication 3 2010-10-01 2010-10-01 false Carrier Common Line hypothetical net balance. 69.608 Section 69.608 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) COMMON CARRIER... net balance. The hypothetical net balance shall be equal to a Carrier Common Line revenue requirement...

  17. Purification of HBsAg produced by the human hepatoma cell line PLC/PRE/5 by affinity chromatography using monoclonal antibodies and application for ELISA diagnostic.

    Merten, O W; Reiter, S; Scheirer, W; Katinger, H

    1983-01-01

    The human cell line PLC/PRF/5 (5) was used for the production of hepatitis B surface antigen subtype ad (HBsAg ad) and purified by affinity chromatography (AC) with monoclonal antibodies (mAb). mAb to HBsAg from mouse ascites have been purified by Protein A - AC prior coupling to AH-Sepharose 4B (Pharmacia). The combined procedure of ammonium-sulphate-precipitation of HBsAg from culture supernatants and immunosorbent-AC leads to approx. 700-fold purification. ELISA results using the mAb and the HBsAg for diagnostics of human serum, positive for anti-HBsAg-antibodies correlate with the RIA (AUSAB, Abbott).

  18. Optical buffer based on monolithic InP phased-array 1×16 switch with silica-PLC pitch converter and ultra-compact coiled fiber delay lines

    Tanemura, T.; Soganci, I. M.; Oyama, T.; Ohyama, T.; Mino, S.; Williams, K. A.; Calabretta, N.; Dorren, H. J S; Nakano, Y.

    2010-01-01

    We demonstrate large-capacity high-resolution optical buffer, comprising 1×16 InP switch and ultra-compact delay lines based on thin-cladding highly nonlinear fibers. Silica-PLC-based pitch converter is employed to realize uniform coupling from all 16 switch ports simultaneously.

  19. 47 CFR 15.113 - Power line carrier systems.

    2010-10-01

    ....113 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES Unintentional... shall submit the details of all existing systems plus any proposed new systems or changes to existing... operation on electric lines which connect the distribution substation to the customer or house wiring. Such...

  20. Transacsys PLC - Final Results

    2002-01-01

    Final results from Transacsys PLC. A subsidary of this company was set up to develop the CERN EDH system into a commercial product but incurred too much financial loss so the project was cancelled (1/2 page).

  1. Fundamentación de la pertinencia y factibilidad de la aplicación domótica mediante la tecnología Power Line Communications PLC para redes domésticas en el Ecuador.

    Suárez Ramos, Diego Fernando

    2015-01-01

    En el presente trabajo se fundamenta la pertinencia y factibilidad de la aplicación domótica mediante la tecnología Power Line Communications PLC, para redes domésticas en el Ecuador. Demostrando que es posible utilizar esta tecnología en los hogares ecuatorianos como una alternativa en los sistemas domóticos existentes. Se presenta como ejemplo diseño para el control de un sistema de iluminación, integrándolo junto con un panel domótico en un domicilio la red eléctric existente.

  2. PLC Berbasis Mikrokontroler Atmega16 Sebagai Pengganti PLC Konvensional

    Brama, Adi; Kurniawan, Syafi’i Agus; Djaohar, Mochammad

    2015-01-01

    Making the research aims to design and build a PLC (Programmable Logic Controller) that uses a microcontroller ATmega16 as the brain of the Micro PLC system. The process of manufacture, testing is done in simulation tools at Pustikom State University of Jakarta and completed the process in May-June 2015. PLC Microcontroller ATmega16-Based As Substitute Conventional PLC, and use the application on a laptop LDmicro to make instructions that form the ladder program to run the output in the form ...

  3. Joint Use of Adaptive Equalization and Cyclic Noise Cancellation for Band-Limited OQAM Based Multi-Carrier Transmission in Power-Line Communication Systems

    Kunishima, Hiromitsu; Koga, Hisao; Muta, Osamu; Akaiwa, Yoshihiko

    Power-line communication (PLC) technique is one method to realize high-speed communications in a home network. In PLC channels, the transmission signal quality is degraded by colored non-Gaussian noise as well as frequency-selectivity of the channels. In this paper, we describe our investigation of the performance of a OQAM-MCT system in which a noise canceller is used jointly with a time-domain per-subcarrier adaptive equalizer. Furthermore, we propose a noise cancellation method designed for the OQAM-MCT system. The performance of the OQAM-MCT system is evaluated in PLC channels with measured impulse responses in the presence of measured noise. Computer simulation results show that the bit rate of the OQAM-MCT system is improved using both an adaptive equalizer and noise canceller, and that the OQAM-MCT system achieves better performance than an OFDM system with an insufficient length of the guard interval.

  4. Reliability analysis of PLC safety equipment

    Yu, J.; Kim, J. Y. [Chungnam Nat. Univ., Daejeon (Korea, Republic of)

    2006-06-15

    FMEA analysis for Nuclear Safety Grade PLC, failure rate prediction for nuclear safety grade PLC, sensitivity analysis for components failure rate of nuclear safety grade PLC, unavailability analysis support for nuclear safety system.

  5. Reliability analysis of PLC safety equipment

    Yu, J.; Kim, J. Y.

    2006-06-01

    FMEA analysis for Nuclear Safety Grade PLC, failure rate prediction for nuclear safety grade PLC, sensitivity analysis for components failure rate of nuclear safety grade PLC, unavailability analysis support for nuclear safety system

  6. Feasibility of high-speed power line carrier system to Japanese overhead low voltage distribution lines; Teiatsu haidensen hanso no kosokuka no kanosei (hanso sningo denpa purogram no kanosei)

    Suzuki, T.; Takeshita, K.; Ishino, R.

    2000-06-01

    The high-speed distribution line carrier systems on underground distribution lines are being developed in Germany. To estimate these systems on Japanese overhead low voltage distribution lines, the Carrier Propagation Program has been developed and applicability of OFDM system was roughly estimated. 1. Carrier Propagation Program Carrier Propagation Program that calculates the carrier propagation characteristics of any line structure was developed. 2. Carrier propagation characteristics Carrier propagation characteristics on typical Japanese overhead low voltage distribution lines were calculated 3.Rough estimation of OFDM system Electric fields caused by carrier at near point were calculated on the basis on carrier propagation characteristics. Results of rough estimation are as follows: - Electric field caused by carrier of more than 2Mbps system exceeds the value of the regulation. (author)

  7. Slovak Electric, Plc., 1997

    1997-06-01

    Slovenske elektrarne, a.s. (Slovak Electric, Plc.) was established on November 1, 1994 as one entity among new entities created as successors to the former Slovensky energeticky podnik. The subject activity is the generation of electric power, operation of transmission 220 kV and 400 kV systems, transit, import, export, and sales of electric power. Besides these activities the company deals with generation, distribution, and sales of heat. The company operates one nuclear power station, three thermal power plants, and thirty hydro power plants. One nuclear Power plant is under construction (state up tu June 1997). On this CD ROM next chapters are presented: (1) The structure of the company; (2) The production Units; (3) The economic power of the company; (4) The operation culture of the company; (5) The strategic plans of the company

  8. Slovak Electric, Plc., 1998

    1997-06-01

    Slovenske elektrarne, a.s. (Slovak Electric, Plc., abbrevation 'SE, a.s.') is the Slovak electricity generating utility, incorporated on November 1, 1994 as one of new companies formed from substantially all of the assets and a legal successor of Slovensky energeticky podnik, s.p., founded on January 1, 1969 in the form of SEP group. From its predecessor, Slovak Electric, Plc., took over generation of power, operation of 220 kV and 400 kV power system, transit, import, export, and sale of electricity. It is also involved in generation, distribution, and sale of heat. At present, SE's share of electriciry sales in the Slovak Republic is 88.47%. Electricity is delivered to three regional distribution companies and directly to several major industrial enterprises. SE, a.s. operates one nuclear power station, three thermal power plants, and 30 hydro power plants. The second nuclear power plant is under construction (state up tu June 1997) and SE is participating in the construction of two hydro power plants and one combined cycle power plant. The efforts of SE, s.a. focus on the generation of power and heat with minimal environmental impacts. Ecology is given priority in the SE, a.s. development programmes. SE's mission is to permanently satisfy customers' needs, for an acceptable price and with minimal environmental impact. On this CD ROM next chapters are presented: (1) The structure of the Company; (2) Production units; (3) The economic power of the Company; (4) The operation culture; (5) The strategic plans of the Company

  9. PLC VVVF Elevator Control System

    Tang, Yujian; Gui, Tianyu

    2016-01-01

    The aim of the thesis is to introduce the PLC VVVF elevator and its control system. The thesis can be divided into three parts. The first part is about the overview of the lift: the kinds of the lift and the structure of the lift, it shows the knowledge about the components and the operating systems of the lift. The second part is about the PLC control system, it’s about the operations of the lift from the introduction about the hardware and software of the PLC control system. And the thi...

  10. Carrier Current Line Systems Technologies in M2M Architecture for Wireless Communication

    Hua-Ching Chen

    2016-01-01

    Full Text Available This paper investigates the Carrier Current Line Systems (CCLS technologies of Machine to Machine (M2M architecture which applied for mobile station coverage working with metro, high speed railway, and subway such as analysis for public transport of an indoor transition system. It is based on the theory and practical engineering principle which provide guidelines and formulas for link budget design to help designers fully control and analyze the single output power of uplink and downlink between Fiber Repeaters (FR and mobile station as well as base station. Finally, the results of this leakage cable system are successfully applied to indoor coverage design for metro rapid transit system which are easily installed cellular over fiber solutions for WCDMA/LTE access is becoming Ubiquitous Network to Internet of Thing (IOT real case hierarchy of telecommunication.

  11. Development of radioactive source scanner based on PLC

    Yang Guogui; Gao Xiang; Guo Hongli

    2013-01-01

    The radioactive radial uniformity of 68 Ge line radioactive sources is a critical quality parameter. The radioactive source scanner with linear scanning function is developed by making use of high-speed pulse counters, high-speed pulse output ports, and the powerful instruction system of Siemens S7-200 series programmable logic controller (PLC). A computer used as a host computer of the instrument communicate with. the PLC by point to point interface (PPI) protocol, The instrument with functions of data collection, transmission, displaying, saving, motion control and instrument parameter settings, can be used to measure the radioactive radial uniformity and total activity of line radioactive source. The advantages of Using the PLC to develop nuclear instrumentation are development speed, strong anti-interference ability, and low-cost. This paper mainly describes the control system implementation and feature of the instrument. (authors)

  12. Spectral radiance of strong lines in positive column mercury discharges with argon carrier gas

    Sansonetti, Craig J; Reader, Joseph

    2006-01-01

    The spectral radiance of the 185 and 254 nm lines in two positive column mercury discharge lamps was measured over a wide range of operating conditions. The lamps had internal diameters of 5 and 23 mm. Argon was used as a carrier gas. The lamps were operated with cold spot temperatures of 20, 40 and 60 0 C. At each of these temperatures, results were obtained for five currents ranging from 20 to 100 mA for the 5 mm lamp and from 200 to 1000 mA for the 23 mm lamp. For each current studied, results were determined for argon pressures ranging from 66.6 to 666 Pa (0.5 to 5.0 Torr) in the 5 mm lamp and 26.6 to 666 Pa (0.2 to 5.0 Torr) in the 23 mm lamp. An argon miniarc was used as the radiometric standard. By calibrating the spectral response of the optical system with a well-characterized mercury pencil lamp, results were obtained for 12 additional Hg lines from 289 to 579 nm. For the 23 mm lamp the electric field in the positive column was measured. For this lamp the radiated power as a percentage of input power was also determined. The results provide an experimental basis for validating computer models of Hg fluorescent lamp discharges

  13. β Absorption dust concentration monitor system based on the PLC

    Lian Dexing; Zhou Xiuliang; Liu Liyan; Li Zonglun; Cao Guanghui; Mao Wanchong

    2011-01-01

    To provide an on-line automatic system for dust concentration monitor is the purpose of this design.The system based on β-ray-absorption-method,employing PLC (Programmable Logic Controller) control technology, is presented. The user input parameter setup,the data acquisition and processing, and the communication with computer can be effectively regulated using the advanced PLC control technology. It has the features of high reliability, easy operation and easy maintenance, and the ability to monitor remotely. Measurement range: 0.1-1500 mg/m 3 , Accuracy: ±9%. The structure,working principle, electric circuit and software development of the system are introduced in detail. (authors)

  14. The PLC: a logical development

    Walker, Mark; Bissell, Christopher; Monk, John

    2010-01-01

    Programmable Logic Controllers (PLCs) have been used to control industrial processes and equipment for over 40 years, having their first commercially recognised application in 1969. Since then there have been enormous changes in the design and application of PLCs, yet developments were evolutionary rather than radical. The flexibility of the PLC does not confine it to industrial use and it has been used for disparate non-industrial control applications . This article reviews the history, deve...

  15. Equity valuation of Tesco Plc.

    Schmitz, Clemens

    2015-01-01

    This dissertation aimed to value the British retailer Tesco Plc. The objective was to determine a target price for the company and as a consequence determine a buy or sell recommendation when comparing it to the current market price. After the state of the art of literature regarding equity valuation has been assessed, the retail industry as well as Tesco have been analysed in more detail. Based on this, the retail business of Tesco has been valued using the Adjusted Present Va...

  16. Usage of Wifi Technology for PLC Programming

    Jaromír ŠKUTA

    2009-06-01

    Full Text Available This contribution describes usage of WIFI technology for programming and parameterization of application in PLC. INSYS WLAN unit from the Microelectronics INSYS Corporation is the base of application. Software access point with using USB WIFI component WL167 is running in industrial PC. Particular PC clients are connecting into network infrastructure PLC by the help of this access point and INSYS WLAN unit. This connection allows configuring and uploading program into this PLC.

  17. Performance Evaluation of CE-OFDM in PLC Channel

    El ghzaoui Mohammed, Belkadid Jamal, Benbassou Ali

    2011-01-01

    One major drawback associated with an OFDM system is that the transmitter’soutput signal may have a high peak-to-average ratio (PAPR). High levels of PARmay be a limiting factor for power line communication (PLC) where regulatorybodies have fixed the maximum amount of transmit power. To overcome thisproblem, many approaches have been presented in the literature. One potentialsolution for reducing the peak-to-average power ratio (PAPR) in an OFDMsystem is to utilize a constant envelope OFDM (C...

  18. Control Systems of Rubber Dryer Machinery Components Using Programmable Logic Control (PLC)

    Hendra; Yulianto, A. S.; Indriani, A.; Hernadewita; Hermiyetti

    2018-02-01

    Application of programmable logic control (PLC) is widely used on the control systems in the many field engineering such as automotive, aviation, food processing and other industries [1-2]. PLC is simply program to control many automatic activity, easy to use, flexible and others. PLC using the ladder program to solve and regulated the control system component. In previous research, PLC was used for control system of rotary dryer machine. In this paper PLC are used for control system of motion component in the rubber dryer machinery. Component of rubber dryer machine is motors, gearbox, sprocket, heater, drying chamber and bearing. Principle working of rubber dryer machinery is wet rubber moving into the drying chamber by sprocket. Sprocket is driven by motors that conducted by PLC to moving and set of wet rubber on the drying chamber. Drying system uses greenhouse effect by making hanger dryer design in the form of line path. In this paper focused on motion control system motors and sensors drying rubber using PLC. The results show that control system of rubber dryer machinery can work in accordance control input and the time required to dry the rubber.

  19. Parameters Evaluation of PLC Dependability and Safety

    Juraj Zdansky

    2006-01-01

    Full Text Available This paper is focused on evaluation of dependability and safety parameters of PLC (Programmable Logic Controller. Achievement of requested level of these parameters is an application assumption for using PLC in control of safety critical processes. Evaluation of these parameters can be made on the base of suitable model and it can be influenced by system architecture when necessary.

  20. Application of PLC in irradiation controlling system

    Qin Wenjuan; Lin Baoling; Wang Mingtao; Huang Daorong; Yao Qiuguo; Gao Weixiang; Yang Kun; Xue Changlin; Pu Jiangling

    2005-01-01

    To deal with the multiprogramming controlling system and computer gathering and printing measure data in Irradiation Station, we adopted Programmable Logic Controller (brief: PLC) instead of PCB to control Irradiation System. PLC improved the anti-jamming ability and debugged for convenience. (authors)

  1. A Classification of PLC Models and Applications

    Mader, Angelika H.; Boel, R.; Stremersch, G.

    In the past years there is an increasing interest in analysing PLC applications with formal methods. The first step to this end is to get formal models of PLC applications. Meanwhile, various models for PLCs have already been introduced in the literature. In our paper we discuss several

  2. Antiphospholipid antibodies detected by line immunoassay differentiate among patients with antiphospholipid syndrome, with infections and asymptomatic carriers.

    Roggenbuck, Dirk; Borghi, Maria Orietta; Somma, Valentina; Büttner, Thomas; Schierack, Peter; Hanack, Katja; Grossi, Claudia; Bodio, Caterina; Macor, Paolo; von Landenberg, Philipp; Boccellato, Francesco; Mahler, Michael; Meroni, Pier Luigi

    2016-05-21

    Antiphospholipid antibodies (aPL) can be detected in asymptomatic carriers and infectious patients. The aim was to investigate whether a novel line immunoassay (LIA) differentiates between antiphospholipid syndrome (APS) and asymptomatic aPL+ carriers or patients with infectious diseases (infectious diseases controls (IDC)). Sixty-one patients with APS (56 primary, 22/56 with obstetric events only, and 5 secondary), 146 controls including 24 aPL+ asymptomatic carriers and 73 IDC were tested on a novel hydrophobic solid phase coated with cardiolipin (CL), phosphatic acid, phosphatidylcholine, phosphatidylethanolamine, phosphatidylglycerol, phosphatidylinositol, phosphatidylserine, beta2-glycoprotein I (β2GPI), prothrombin, and annexin V. Samples were also tested by anti-CL and anti-β2GPI ELISAs and for lupus anticoagulant activity. Human monoclonal antibodies (humoAbs) against human β2GPI or PL alone were tested on the same LIA substrates in the absence or presence of human serum, purified human β2GPI or after CL-micelle absorption. Comparison of LIA with the aPL-classification assays revealed good agreement for IgG/IgM aß2GPI and aCL. Anti-CL and anti-ß2GPI IgG/IgM reactivity assessed by LIA was significantly higher in patients with APS versus healthy controls and IDCs, as detected by ELISA. IgG binding to CL and ß2GPI in the LIA was significantly lower in aPL+ carriers and Venereal Disease Research Laboratory test (VDRL) + samples than in patients with APS. HumoAb against domain 1 recognized β2GPI bound to the LIA-matrix and in anionic phospholipid (PL) complexes. Absorption with CL micelles abolished the reactivity of a PL-specific humoAb but did not affect the binding of anti-β2GPI humoAbs. The LIA and ELISA have good agreement in detecting aPL in APS, but the LIA differentiates patients with APS from infectious patients and asymptomatic carriers, likely through the exposure of domain 1.

  3. INTERACTION BETWEEN THE BROAD-LINED TYPE Ic SUPERNOVA 2012ap AND CARRIERS OF DIFFUSE INTERSTELLAR BANDS

    Milisavljevic, Dan; Margutti, Raffaella; Crabtree, Kyle N.; Soderberg, Alicia M.; Sanders, Nathan E.; Drout, Maria R.; Kamble, Atish; Chakraborti, Sayan; Kirshner, Robert P.; Foster, Jonathan B.; Fesen, Robert A.; Parrent, Jerod T.; Pickering, Timothy E.; Cenko, S. Bradley; Silverman, Jeffrey M.; Marion, G. H. Howie; Vinko, Jozsef; Filippenko, Alexei V.; Mazzali, Paolo; Maeda, Keiichi

    2014-01-01

    Diffuse interstellar bands (DIBs) are absorption features observed in optical and near-infrared spectra that are thought to be associated with carbon-rich polyatomic molecules in interstellar gas. However, because the central wavelengths of these bands do not correspond to electronic transitions of any known atomic or molecular species, their nature has remained uncertain since their discovery almost a century ago. Here we report on unusually strong DIBs in optical spectra of the broad-lined Type Ic supernova SN 2012ap that exhibit changes in equivalent width over short (≲ 30 days) timescales. The 4428 Å and 6283 Å DIB features get weaker with time, whereas the 5780 Å feature shows a marginal increase. These nonuniform changes suggest that the supernova is interacting with a nearby source of DIBs and that the DIB carriers possess high ionization potentials, such as small cations or charged fullerenes. We conclude that moderate-resolution spectra of supernovae with DIB absorptions obtained within weeks of outburst could reveal unique information about the mass-loss environment of their progenitor systems and provide new constraints on the properties of DIB carriers

  4. Preliminary studies of using preheated carrier gas for on-line membrane extraction of semivolatile organic compounds.

    Liu, Xinyu; Pawliszyn, Janusz

    2007-04-01

    In this paper, we present results for the on-line determination of semivolatile organic compounds (SVOCs) in air using membrane extraction with a sorbent interface-ion mobility spectrometry (MESI-IMS) system with a preheated carrier (stripping) gas. The mechanism of the mass transfer of SVOCs across a membrane was initially studied. In comparison with the extraction of volatile analytes, the mass transfer resistance that originated from the slow desorption from the internal membrane surface during the SVOC extraction processes should be taken into account. A preheated carrier gas system was therefore built to facilitate desorption of analytes from the internal membrane surface. With the benefit of a temperature gradient existing between the internal and external membrane surfaces, an increase in the desorption rate of a specific analyte at the internal surface and the diffusion coefficient within the membrane could be achieved while avoiding a decrease of the distribution constant on the external membrane interface. This technique improved both the extraction rate and response times of the MESI-IMS system for the analysis of SVOCs. Finally, the MESI-IMS system was shown to be capable of on-site measurement by monitoring selected polynuclear aromatic hydrocarbons emitted from cigarette smoke.

  5. INTERACTION BETWEEN THE BROAD-LINED TYPE Ic SUPERNOVA 2012ap AND CARRIERS OF DIFFUSE INTERSTELLAR BANDS

    Milisavljevic, Dan; Margutti, Raffaella; Crabtree, Kyle N.; Soderberg, Alicia M.; Sanders, Nathan E.; Drout, Maria R.; Kamble, Atish; Chakraborti, Sayan; Kirshner, Robert P. [Harvard-Smithsonian Center for Astrophysics, 60 Garden St., Cambridge, MA 02138 (United States); Foster, Jonathan B. [Yale Center for Astronomy and Astrophysics, Yale University, New Haven, CT 06520 (United States); Fesen, Robert A.; Parrent, Jerod T. [Department of Physics and Astronomy, Dartmouth College, 6127 Wilder Lab, Hanover, NH 03755 (United States); Pickering, Timothy E. [Southern African Large Telescope, P.O. Box 9, Observatory 7935, Cape Town (South Africa); Cenko, S. Bradley [Astrophysics Science Division, NASA Goddard Space Flight Center, Mail Code 661, Greenbelt, MD 20771 (United States); Silverman, Jeffrey M.; Marion, G. H. Howie; Vinko, Jozsef [University of Texas at Austin, 1 University Station C1400, Austin, TX 78712-0259 (United States); Filippenko, Alexei V. [Department of Astronomy, University of California, Berkeley, CA 94720-3411 (United States); Mazzali, Paolo [Astrophysics Research Institute, Liverpool John Moores University, Liverpool L3 5RF (United Kingdom); Maeda, Keiichi, E-mail: dmilisav@cfa.harvard.edu [Department of Astronomy, Kyoto University Kitashirakawa-Oiwake-cho, Sakyo-ku, Kyoto 606-8502 (Japan); and others

    2014-02-10

    Diffuse interstellar bands (DIBs) are absorption features observed in optical and near-infrared spectra that are thought to be associated with carbon-rich polyatomic molecules in interstellar gas. However, because the central wavelengths of these bands do not correspond to electronic transitions of any known atomic or molecular species, their nature has remained uncertain since their discovery almost a century ago. Here we report on unusually strong DIBs in optical spectra of the broad-lined Type Ic supernova SN 2012ap that exhibit changes in equivalent width over short (≲ 30 days) timescales. The 4428 Å and 6283 Å DIB features get weaker with time, whereas the 5780 Å feature shows a marginal increase. These nonuniform changes suggest that the supernova is interacting with a nearby source of DIBs and that the DIB carriers possess high ionization potentials, such as small cations or charged fullerenes. We conclude that moderate-resolution spectra of supernovae with DIB absorptions obtained within weeks of outburst could reveal unique information about the mass-loss environment of their progenitor systems and provide new constraints on the properties of DIB carriers.

  6. Homeplug AV and IEEE 1901 a handbook for PLC designers and users

    Latchman, Haniph A; Yonge, Larry; Gavette, Sherman

    2013-01-01

      The only authorized book explaining the HomePlug networking standards HomePlug is a growing technology for creating high-speed Power Line Communication (PLC) networks by transmitting data over in-home or in-office power lines. Users only need to plug adapters into wall outlets to create an instant network of computers, printers, routers, home entertainment

  7. PLC control of 50 MW klystron modulators

    Shang Lei; Liu Gongfa; Chen Liping; Lu Yeming; Hong Jun; Zhang Yi; Zhao Feng

    2004-01-01

    Upgrade project of the 50 MW klystron modulators of Hefei Light Source (HLS) was firstly introduced. PLC control system of modulators was employed to replace the old control and monitor system, which was based on relay logic circuit and manual operation method. the PLC system becomes a sub system of the new EPICS control system of HLS. Constant-current, switch-mode and high voltage power supplies were adopted to replace the old 50 Hz power supplies. The technology of modulators was improved and operation was more reliable. The design method, hardware and software of PLC control of modulators were described and the performance was presented. (authors)

  8. Diseño e implementación de un sistema de transferencias de datos a través de la red eléctrica de baja tensión con la interfaz Labview-arduino empleando la tecnología power line communications (PLC).

    Ponce León, David; Santillán Aguirre, Sergio

    2016-01-01

    La propuesta del proyecto de titulación está basada en la implementación de un nuevo sistema de transferencia mediante tecnología Power Line Communications (PLC), Comunicación por la Red Eléctrica, que se fundamenta en la transmisión de información en diferentes puntos utilizando la red eléctrica ya existente de baja tensión en el Laboratorio de Telecomunicaciones, con la finalidad de contribuir con nuevas opciones de comunicación, de envío y recepción de información para aplicaciones tecnoló...

  9. Application of PLC to mine hoist

    Zheng Liquan

    2003-01-01

    This paper describes the reform of the hoister JMK 1.85 x 4 (B) with programmable logic controller (PLC), introduces hardware architecture, software architecture and interference protection measures, and presents the existential problems and suggestions for improvement

  10. Automated Formal Verification for PLC Control Systems

    Fernández Adiego, Borja

    2014-01-01

    Programmable Logic Controllers (PLCs) are widely used devices used in industrial control systems. Ensuring that the PLC software is compliant with its specification is a challenging task. Formal verification has become a recommended practice to ensure the correctness of the safety-critical software. However, these techniques are still not widely applied in industry due to the complexity of building formal models, which represent the system and the formalization of requirement specifications. We propose a general methodology to perform automated model checking of complex properties expressed in temporal logics (e.g. CTL, LTL) on PLC programs. This methodology is based on an Intermediate Model (IM), meant to transform PLC programs written in any of the languages described in the IEC 61131-3 standard (ST, IL, etc.) to different modeling languages of verification tools. This approach has been applied to CERN PLC programs validating the methodology.

  11. Lipogenesis and glucose production in dwarf carrier and normal lines of chicks

    Rosebrough, R.W.; McMurtry, J.P.; Steele, N.C.

    1986-01-01

    Diets containing 13, 16, 19, or 23% protein and 70% carbohydrate calories were fed to dwarf heterozygote (dw) and normal (Dw) chickens to determine the effects of age (weeks) and protein on intermediary metabolism. In vitro lipogenesis (IVL) was determined by the incorporation of acetate (10 and 20 mM 2 14 C-Acet/2hr) into hepatic fatty acids. Net glucose production (NGP) was determined as the difference in media glucose in the presence or absence of 10 mM pyruvate. Values were expressed per unit of relative liver size (μmoles/100 g BWt). Serum insulin (INS; ng/ml) was determined by homologous radioimmunoassay. Results indicate that although INS was greater in Dw than in dw, this difference was not reflected in a decreased rate of glucose production to accompany the difference in IVL between the two lines. Moreover, an increase in dietary protein resulted in a decrease in IVL but an increase in INS

  12. Using of Finite Automation at Programming PLC

    Karol Rastocny

    2004-01-01

    Full Text Available The paper is concerning with systematic advances at programming programmable logic controllers (PLC, which comes out from algebraic description of behaviour of sequential circuit, in the way of finite automaton. This kind of access is streamlining the work of a programmer and enabling to use formalisms in the of whole process of system development, that is from process of analysing demands to process of verification and validation created program. The paper considers about using of ladder diagram at programming PLC.

  13. Frequency domain based LS channel estimation in OFDM based Power line communications

    Bogdanović, Mario

    2015-01-01

    This paper is focused on low voltage power line communication (PLC) realization with an emphasis on channel estimation techniques. The Orthogonal Frequency Division Multiplexing (OFDM) scheme is preferred technology in PLC systems because of its effective combat with frequency selective fading properties of PLC channel. As the channel estimation is one of the crucial problems in OFDM based PLC system because of a problematic area of PLC signal attenuation and interference, the improved LS est...

  14. 77 FR 37740 - Stagecoach Group plc and Coach USA, Inc., et al.-Acquisition of Control of Assets-American Coach...

    2012-06-22

    ... Application. SUMMARY: On May 25, 2012, Stagecoach Group plc (Stagecoach), a noncarrier, and a number of its... Group plc and Coach USA, Inc., et al.--Acquisition of Control of Assets--American Coach Lines of Atlanta...) filed an application under 49 U.S.C. 14303 to acquire control of the assets of ten separate interstate...

  15. NB-PLC channel modelling with cyclostationary noise addition & OFDM implementation for smart grid

    Thomas, Togis; Gupta, K. K.

    2016-03-01

    Power line communication (PLC) technology can be a viable solution for the future ubiquitous networks because it provides a cheaper alternative to other wired technology currently being used for communication. In smart grid Power Line Communication (PLC) is used to support communication with low rate on low voltage (LV) distribution network. In this paper, we propose the channel modelling of narrowband (NB) PLC in the frequency range 5 KHz to 500 KHz by using ABCD parameter with cyclostationary noise addition. Behaviour of the channel was studied by the addition of 11KV/230V transformer, by varying load location and load. Bit error rate (BER) Vs signal to noise ratio SNR) was plotted for the proposed model by employing OFDM. Our simulation results based on the proposed channel model show an acceptable performance in terms of bit error rate versus signal to noise ratio, which enables communication required for smart grid applications.

  16. Design and Implementation of an over Current Protection Laboratory for Electrical Power Transmission Systems Based on PLC Techniques

    Hassaan Th. H. Thabet

    2018-01-01

    Full Text Available This paper describes a modern approach for the protection of transmission lines to ensure theirsafety against the faults occurred in power systems. Our approach uses a Programmable LogicController (PLC to realize a transmission line as an over current protection relay. A conditioningcircuit was designed, implemented and tested to collect data obtained from Hall Effect sensors which convert them to suitable analog values compatible with PLC's inputs. Results obtained by our PLC control system are very similar to those obtained by the conventional relays but more efficient. An Automatic Reclosing System (ARS for remote faults is also included in this approach. Our PLC control system and its algorithm are illustrated in this paper also. This approach is designed to be used in electrical networks laboratories as an educational unit in electrical departments of engineering collages and technical institutes; it can be used also in real power systems through suitable interfacing facilities.

  17. Cybersecurity Vulnerability Analysis of the PLC PRIME Standard

    Miguel Seijo Simó

    2017-01-01

    Full Text Available Security in critical infrastructures such as the power grid is of vital importance. The Smart Grid puts power grid classical security approach on the ropes, since it introduces cyberphysical systems where devices, communications, and information systems must be protected. PoweRline Intelligent Metering Evolution (PRIME is a Narrowband Power-Line Communications (NB-PLC protocol widely used in the last mile of Advanced Metering Infrastructure (AMI deployments, playing a key role in the Smart Grid. Therefore, this work aims to unveil the cybersecurity vulnerabilities present in PRIME standard, proposing solutions and validating and discussing the results obtained.

  18. Performance Evaluation of CE-OFDM in PLC Channel

    El Ghzaoui Mohammed; Belkadid Jamal; Benbassou Ali

    2011-01-01

    One major drawback associated with an OFDM system is that the transmitter’s output signal may have a high peak-to-average ratio (PAPR). High levels of PAR may be a limiting factor for power line communication (PLC) where regulatory bodies have fixed the maximum amount of transmit power. To overcome this problem, many approaches have been presented in the literature. One potential solution for reducing the peak-to-average power ratio (PAPR) in an OFDM system is to utilize a constant envelope O...

  19. The electromagnetic compatibility of the PLC technology; La compatibilite electromagnetique de la technologie CPL. Des donnees sur les lignes electriques

    Bermudez, J.-L.; Marthe, E.; Rachidi, F.; Rubinstein, M.; Vukicevic, A.

    2006-07-01

    PLC (Power Line Communications) in Europe or BPL (Broadband over Power Lines) in the US are techniques that allows the utilization of low and middle voltage power lines for the transmission of high frequencies by coupling electrical signals to them. In this way, unshielded power lines may be used for the transmission of numerical information similar to the well known xDSL-techniques using telephone lines. Typically, the frequency range used by PLC is between 9 kHz and 30 MHz. The authors describe the general principles and investigate possible electromagnetic interference with existing radio frequency equipment like xDSL, CATV (Cable Television) and Wireless (GSM, Bluetooth, WiFi). Finally, they present theoretical and experimental results of techniques allowing the reduction of such interference by reducing the emission of electromagnetic signals from PLC systems. The preferred method is based on an active control by injecting an auxiliary signal into the third conductor (ground)

  20. PLC-Based Pressure Control in Multi-Pump Applications

    Vodovozov Valery

    2015-12-01

    Full Text Available The paper is devoted to the centrifugal pumps represented the most popular type of pumping equipment used in different areas. The pressure control approach for variable speed driven (VSD parallel connected centrifugal pumps is reported. The goal of the study is optimization of some quality indices, such as efficiency, consumed power, productivity, energy carrier temperature, heat irradiation, etc. One of them – efficiency – has been studied in the paper more carefully. The mathematical model of pumping process is discussed and a vector-matrix description of the multi-pump application is given. The program-based pressure control system is developed which productivity is changed by regulating the number of working pumps. The paper introduces new pressure control algorithms based on the working point estimation intended for programmable logical controllers (PLC. Experiments prove correctness of the offered methodology.

  1. Automated turn pike using PLC and SCADA

    Silpa Sreedhar, P.; Aiswarya, P.; Kathirvelan, J.

    2017-11-01

    We propose a smart turnpike based on Programmable Logic Controller (PLC) and Supervisory Control and Data Acquisition Systems (SCADA) in this paper. In this work, the basic idea is to measure the weight of the vehicles and classify them according to its weight to the respective lanes. It is difficult for the turnpike people to monitor the whole process all the time. So, this PLC based diversion system can be implemented in turnpikes to reduce the difficulties. This method will work based on weight sensors (piezo-resistive) whose output will be fed to a PLC, which will control the vehicle diversion. Using SCADA software, the whole process can be monitored from a remote area. The algorithm developed in this successfully installed in real time system.

  2. Enterprise network with software Asterisk PBX based on the PLC technology

    Michal Maar

    2017-01-01

    Full Text Available This article presents the software Asterisk PBX solution design in enterprise PLC network (Power Line Communication. The description of the installation and configuration of software Asterisk PBX is involved in the design. The secure interconnection of two enterprise PLC network is implemented via the telecommunication tunnel with security grant using the Cisco routers. The connection between two Asterisk PBXs is designed in context of the establishment of the tunnel. The subject of the article is also cross/connection of exchanges Asterisk PBX and hardware PBX - IP Panasonic PBX K-NS500.

  3. Empirical P-L-C relations for delta Scuti stars

    Gupta, S.K.

    1978-01-01

    Separate P-L-C relations have been empirically derived by sampling the delta Scuti stars according to their pulsation modes. The results based on these relations have been compared with those estimated from the model based P-L-C relations and the other existing empirical P-L-C relations. It is found that a separate P-L-C relation for each pulsation mode provides a better correspondence with observations. (Auth.)

  4. Wavelet-OFDM Signal Transmission Characteristics with High-Speed PLC Modem

    Nakagawa, Kenichi; Tokuda, Masamitsu; Igata, Yuji

    In this paper, we measured the interference immunity characteristics of high-speed PLC system using Wavelet-OFDM when the narrowband conducted interference wave signal was injected. As the results, it was clear that (1) measured PHY rate at the all frequency band hardly decreased in C/I (Carrier to Interference ratio) of above 20dB, but began to decrease rapidly in C/I of below 0dB when the interference signal was injected in the frequency band of high-speed PLC signal, (2) when C/I became from 0dB to -20dB, the measured PHY rate at the frequency existing the notch band were improved around 10Mbps than that at the frequency not existing the notch band, (3) when the narrowband interference wave was injected outside of frequency band of high-speed PLC signal, the measured PHY rate did not decrease than that in each notch band. Therefore, it was revealed that high-speed PLC system using Wavelet-OFDM had good interference immunity characteristics.

  5. The application of PLC in 60Co container inspection system

    Huang Yibin; Xiang Xincheng

    2001-01-01

    The author discusses the interlock technique of 60 Co container inspection system, and introduces the hardware structure and program of interlock control system using PLC. Due to adopting PLC distributed control, the system works stably and reliably. The successful application of PLC in 60 Co container inspection system has some use for reference in nuclear technology field

  6. Amersham International plc. Report and Accounts 1995

    1995-01-01

    The Annual Report and Accounts for Amersham International plc for the year 1995 are presented. This leading health science company develops products, services and technologies based on its expertise in labelling and detection at the molecular level. Recent work in the fields of life science research, nuclear medicine and industrial quality and safety assurance are described. (UK)

  7. Development of tools for automatic generation of PLC code

    Koutli, Maria; Chasapis, Georgios; Rochez, Jacques

    2014-01-01

    This Master thesis was performed at CERN and more specifically in the EN-ICE-PLC section. The Thesis describes the integration of two PLC platforms, that are based on CODESYS development tool, to the CERN defined industrial framework, UNICOS. CODESYS is a development tool for PLC programming, based on IEC 61131-3 standard, and is adopted by many PLC manufacturers. The two PLC development environments are, the SoMachine from Schneider and the TwinCAT from Beckhoff. The two CODESYS compatible P...

  8. Low cytotoxicity effect of dendrosome as an efficient carrier for rotavirus VP2 gene transferring into a human lung cell line : dendrosome, as a novel intranasally gene porter.

    Pourasgari, Farzaneh; Ahmadian, Shahin; Salmanian, Ali Hatef; Sarbolouki, Mohammad Nabi; Massumi, Mohammad

    2009-01-01

    The efficiency of dendrosome (a gene porter) was assessed in transferring recombinant human rotavirus VP2 cDNA into A549, a human lung cell line. After gene transferring, transmission electron microscopy showed core-like particles (CLPs) formation in the transfected cells both with dendrosome and lipofectamine porters. In addition, western blotting analysis showed that the expression of VP2 gene was almost equal in the dendrosome and lipofectamine-transfected cells. Also, the cytotoxicity studies revealed that dendrosome had a lower cytotoxicity than lipofectamine. Therefore, our study may introduce dendrosome as a possible carrier for gene transferring into the human lung cell line, especially, for intranasally administration of DNA vaccines.

  9. Automation of Underground Cable Laying Equipment Using PLC and Hmi

    Mal Kothari, Kesar; Samba, Vishweshwar; Tania, Kinza; Udayakumar, R., Dr; Karthikeyan, Ram, Dr

    2018-04-01

    Underground cable laying is an alternative for overhead cable laying of telecommunication and power transmission lines. It is becoming very popular in recent times because of some of its advantages over overhead cable laying. This type of cable laying is mostly practiced in developed countries because it is more expensive than overhead cable laying. Underground cable laying is more suitable when land is not available, and it also increases the aesthetics. This paper implements the automation on a manually operated cable pulling winch machine using programmable logic controller (PLC). Winch machines are useful in underground cable laying. The main aim of the project is to replace all the mechanical functions with electrical controls which are operated through a touch screen (HMI). The idea is that the machine should shift between parallel and series circuit automatically based on the pressure sensed instead of manually operating the solenoid valve. Traditional means of throttling the engine using lever and wire is replaced with a linear actuator. Sensors such as proximity, pressure and load sensor are used to provide the input to the system. The HMI used will display the speed, length and tension of the rope being winded. Ladder logic is used to program the PLC.

  10. Intelligent Traffic Light Based on PLC Control

    Mei, Lin; Zhang, Lijian; Wang, Lingling

    2017-11-01

    The traditional traffic light system with a fixed control mode and single control function is contradicted with the current traffic section. The traditional one has been unable to meet the functional requirements of the existing flexible traffic control system. This paper research and develop an intelligent traffic light called PLC control system. It uses PLC as control core, using a sensor module for receiving real-time information of vehicles, traffic control mode for information to select the traffic lights. Of which control mode is flexible and changeable, and it also set the countdown reminder to improve the effectiveness of traffic lights, which can realize the goal of intelligent traffic diversion, intelligent traffic diversion.

  11. Event notification system with a PLC

    Kawase, M.; Yoshikawa, Hiroshi; Sakaki, Hironao; Takahashi, Hiroki; Sako, Hiroyuki; Kamiya, Junichiro; Takayanagi, Tomohiro

    2004-01-01

    When an interlock occurs in the equipment, it is required to notify the upper rank control system of the Interlock and receive information for apparatus information in the upper rank control system as at high speed as possible. In the apparatus using FA-M3, it can respond to this by using the notice function of an event. This report shows the event notification system with a PLC based Kicker electromagnet power supply for 3GeV RCS. (author)

  12. PLC Based Automatic Multistoried Car Parking System

    Swanand S .Vaze; Rohan S. Mithari

    2014-01-01

    This project work presents the study and design of PLC based Automatic Multistoried Car Parking System. Multistoried car parking is an arrangement which is used to park a large number of vehicles in least possible place. For making this arrangement in a real plan very high technological instruments are required. In this project a prototype of such a model is made. This prototype model is made for accommodating twelve cars at a time. Availability of the space for parking is detecte...

  13. Trend on High-speed Power Line Communication Technology

    Ogawa, Osamu

    High-speed power line communication (PLC) is useful technology to easily build the communication networks, because construction of new infrastructure is not necessary. In Europe and America, PLC has been used for broadband networks since the beginning of 21th century. In Japan, high-speed PLC was deregulated only indoor usage in 2006. Afterward it has been widely used for home area network, LAN in hotels and school buildings and so on. And recently, PLC is greatly concerned as communication technology for smart grid network. In this paper, the author surveys the high-speed PLC technology and its current status.

  14. PLC based control system for RAM assembly test facility

    Kulkarni, S.S.; Kumar, Vinaya; Chandra, Umesh

    1994-01-01

    The flexibility, expandability, ease of programming and diagnostic features makes the programmable logic controller (PLC) suitable for a variety of control applications in engineering system test facilities. A PLC based control system for RAM assembly test facility (RATF) and for testing the related hydraulic components is being developed and installed at BARC. This paper describes the approach taken for meeting the control requirements and illustrates the PLC software that has been developed. (author). 1 fig

  15. Practical application with plc in manipulation of a robotic arm

    Cristian Barz

    2014-12-01

    Full Text Available This paper presents the use of a robotic arm PLC Siemens in order not using CNC commands. This is done by programming the PLC ladder diagram language that makes movement on the three axes of the arm by means of stepper motors. Required command console PLC is built with the help of a touch screen HMI Weintek. In the user interface are introduced distances and displacement speeds on the three axes.

  16. On Construction and Verification of PLC-Programs

    E. V. Kuzmin

    2012-01-01

    Full Text Available We review some methods and approaches to programming discrete problems for Programmable Logic Controllers on the example of constructing PLC-programs for controling a code lock. For these approaches we evaluate the usability of the model checking method for the analysis of program correctness with respect to the automatic verification tool Cadence SMV. Some possible PLC-program vulnerabilities arising at a number approaches to programming of PLC are revealed.

  17. Development of tools for automatic generation of PLC code

    Koutli, Maria; Rochez, Jacques

    This Master thesis was performed at CERN and more specifically in the EN-ICE-PLC section. The Thesis describes the integration of two PLC platforms, that are based on CODESYS development tool, to the CERN defined industrial framework, UNICOS. CODESYS is a development tool for PLC programming, based on IEC 61131-3 standard, and is adopted by many PLC manufacturers. The two PLC development environments are, the SoMachine from Schneider and the TwinCAT from Beckhoff. The two CODESYS compatible PLCs, should be controlled by the SCADA system of Siemens, WinCC OA. The framework includes a library of Function Blocks (objects) for the PLC programs and a software for automatic generation of the PLC code based on this library, called UAB. The integration aimed to give a solution that is shared by both PLC platforms and was based on the PLCOpen XML scheme. The developed tools were demonstrated by creating a control application for both PLC environments and testing of the behavior of the code of the library.

  18. Effects of GC temperature and carrier gas flow rate on on-line oxygen isotope measurement as studied by on-column CO injection.

    Chen, Zhi-Gang; Yin, Xi-Jie; Zhou, Youping

    2015-08-01

    Although deemed important to δ 18 O measurement by on-line high-temperature conversion techniques, how the GC conditions affect δ 18 O measurement is rarely examined adequately. We therefore directly injected different volumes of CO or CO-N 2 mix onto the GC column by a six-port valve and examined the CO yield, CO peak shape, CO-N 2 separation, and δ 18 O value under different GC temperatures and carrier gas flow rates. The results show the CO peak area decreases when the carrier gas flow rate increases. The GC temperature has no effect on peak area. The peak width increases with the increase of CO injection volume but decreases with the increase of GC temperature and carrier gas flow rate. The peak intensity increases with the increase of GC temperature and CO injection volume but decreases with the increase of carrier gas flow rate. The peak separation time between N 2 and CO decreases with an increase of GC temperature and carrier gas flow rate. δ 18 O value decreases with the increase of CO injection volume (when half m/z 28 intensity is rate. On average, the δ 18 O value of the injected CO is about 1‰ higher than that of identical reference CO. The δ 18 O distribution pattern of the injected CO is probably a combined result of ion source nonlinearity and preferential loss of C 16 O or oxygen isotopic exchange between zeolite and CO. For practical application, a lower carrier gas flow rate is therefore recommended as it has the combined advantages of higher CO yield, better N 2 -CO separation, lower He consumption, and insignificant effect on δ 18 O value, while a higher-than-60 °C GC temperature and a larger-than-100 µl CO volume is also recommended. When no N 2 peak is expected, a higher GC temperature is recommended, and vice versa. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  19. Csseverin inhibits apoptosis through mitochondria-mediated pathways triggered by Ca2 + dyshomeostasis in hepatocarcinoma PLC cells.

    Mengchen Shi

    2017-11-01

    Full Text Available Numerous experimental and epidemiological studies have demonstrated a link between Clonorchis sinensis (C. sinensis infestation and cholangiocarcinoma (CCA as well as hepatocellular carcinoma (HCC. The underlying molecular mechanism involved in the malignancy of CCA and HCC has not yet been addressed. Csseverin, a component of the excretory/secretory products of C. sinensis (CsESPs, was confirmed to cause obvious apoptotic inhibition in the human HCC cell line PLC. However, the antiapoptotic mechanism is unclear. In the present study, we investigated the cellular features of the antiapoptotic mechanism upon transfection of the Csseverin gene.In the present study, we evaluated the effects of Csseverin gene overexpression on the apoptosis of PLC cells using an Annexin PE/7-AAD assay. Western blotting was applied to quantify the activation of caspase-3 and caspase-9, the mitochondrial translocation of Bax and the release of Cyt c upon Csseverin overexpression in PLC cells. Laser scanning confocal microscopy was used to analyze the changes of intracellular calcium. Fluorescence assay and immunofluorescence assays were performed to observe the changes of the mitochondrial permeability transition pore (MPTP.The overexpression of Csseverin in PLC cells showed apoptosis resistance after the induction of apoptosis. Additionally, the activation of caspase-3 and caspase-9 was specifically weakened in Csseverin overexpression PLC cells. The overexpression of Csseverin reduced the increase in intracellular free Ca2+, thereby inhibiting MPTP opening in PLC cells. Moreover, Bax mitochondrial translocation and the subsequent release of Cyt c were downregulated in apoptotic Csseverin overexpression PLC cells.The present findings suggest that Csseverin, a component of CsESPs, confers protection from human HCC cell apoptosis via the inactivation of membranous Ca2+ channels. Csseverin might be involved in the process of HCC through C. sinensis infestation in

  20. Process optimization and photostability of silymarin nanostructured lipid carriers: effect on UV-irradiated rat skin and SK-MEL 2 cell line.

    Singh, Pooja; Singh, Mahendra; Kanoujia, Jovita; Arya, Malti; Saraf, Shailendra K; Saraf, Shubhini A

    2016-10-01

    The objective of the present work was to formulate a novel stable delivery system which would not only overcome the solubility issue of silymarin, but also help to increase the therapeutic value by better permeation, anticancer action and reduced toxicity. This was envisaged through the recent developments in nanotechnology, combined with the activity of the phytoconstituent silymarin. A 2(3) full factorial design based on three independent variables was used for process optimization of nanostructured lipid carriers (NLC). Developed formulations were evaluated on the basis of particle size, morphology, in vitro drug release, photostability and cell line studies. Optimized silymarin-NLC was incorporated into carbopol gel and further assessed for rheological parameters. Stable behaviour in presence of light was proven by photostability testing of formulation. Permeability parameters were significantly higher in NLC as compared to marketed phytosome formulation. The NLC based gel described in this study showed faster onset, and prolonged activity up to 24 h and better action against edema as compared to marketed formulation. In case of anticancer activity of silymarin-NLC against SK-MEL 2 cell lines, silymarin-NLC proved to possess anticancer activity in a dose-dependent manner (10-80 μM) and induced apoptosis at 80 μM in SK-MEL 2 cancer cells. This work documents for the first time that silymarin can be formulated into nanostructured lipoidal carrier system for enhanced permeation, greater stability as well as anticancer activity for skin.

  1. Model to Counter the Threats in the Data Transmission System PLC-based Technology with the Use of Petri Nets

    A. A. Balaev

    2010-06-01

    Full Text Available In the article the most important aspects of information security technology Power Line Communica tions, namely the provision of conditions accessibility and integrity, are considered. It is shown that these aspects of the PLC-Technology has some internal “potential” counter, at least, such a widespread threat to both natural disturbances and/or artificial origin. The possibility of such an implementation using the simplified mathematical model of the PLC-based technologies of the theory of Petri nets is presented.

  2. Design and development of PLC based offline impedance matching system for ICRH experiment

    Joshi, Ramesh; Jadav, H.M.; Mali, Aniruddh; Kulkarni, S.V.

    2015-01-01

    Ion Cyclotron Resonance Heating (ICRH) transmission line has two impedance matching networks, one for offline matching which has been employed before experimental shot. Another is online impedance matching which has been employed during experimental shot. Offline matching network consists of two static stubs, coarse tuner and coarse phase shifter identical in both transmission lines. There are motorized arrangement installed in each stubs and phase shifters. Both stubs are being used to vary transmission line length. Phase shifter is used to match the frequency of generated RF power. Programmable Logic Controller (PLC) based automation and control technique has been designed and developed for the system. Offline matching should be operated below 1 kHz frequency in order to move stepper motors. Program generates required square pulses which employed to motor controller to move either in upward or downward direction. In existing system this operation has been carried out using VME. To reduce the load on VME, PLC based system has been designed and integrated with main DAC system. WinCC software has been used (as SCADA/HMI) to develop front end GUI which communicates with OPC server. Further, OPC communicates with PLC for control of motorized arrangement. This paper describes technical details,design and development of PLC based offline matching system using WinCC as user interface. The communication between WinCC application and hardware devices was realized by OPC technique. The developed system has friendly graphical user interface, high-level automation and comprehensive function such as experimental process control. The system was proved to be reliable and accurate in practical application. (author)

  3. Generic requirements specification for qualifying a commercially available PLC for safety-related applications in nuclear power plants. Final report

    Ostenso, A.; May, R.

    1996-12-01

    This is a specification for qualifying a commercially available PLC for application to safety systems in nuclear power plants. The specifications are suitable for evaluating a particular PLC product line as a platform for safety-related applications, establishing a suitable qualification test program, and confirming that the manufacturer has a quality assurance program that is adequate for safety-related applications or is sufficiently complete that, with a reasonable set of compensatory actions, it can be brought into conformance. The specification includes requirements for: (1) quality assurance measures applied to the qualification activities, (2) documentation to support the qualification, and (3) documentation to provide the information needed for applying the qualified PLC platform to a specific application. The specifications are designed to encompass a broad range of safety applications; however, qualifying a particular platform for a different range of applications can be accomplished by appropriate adjustments to the requirements

  4. Heating systems with PLC and frequency control

    Abdallah, Salah; Abu-Mallouh, Riyad

    2008-01-01

    In this work, medium capacity controlled heating system is designed and constructed. The programming method of control of heating process is achieved by means of integrated programmable logic controller (PLC) and frequency inverter (FI). The PLC main function is to determine the required temperatures levels and the related time intervals of the heating hold time in the furnace. FI is used to control the dynamic change of temperature between various operating points. The designed system shows the capability for full control of temperature from zero to maximum for any required range of time in case of increasing or decreasing the temperature. All variables of the system will be changed gradually until reaching their needed working points. An experimental study was performed to investigate the effect of tempering temperature and tempering time on hardness and fatigue resistance of 0.4% carbon steel. It was found that increasing tempering temperature above 550 deg. C or tempering time decreases the hardness of the material. It was also found that there is a maximum number of cycles to which the specimen can survive what ever the applied load was

  5. Reliability Analysis for Safety Grade PLC(POSAFE-Q)

    Choi, Kyung Chul; Song, Seung Whan; Park, Gang Min; Hwang, Sung Jae

    2012-01-01

    Safety Grade PLC(Programmable Logic Controller), POSAFE-Q, was developed recently in accordance with nuclear regulatory and requirements. In this paper, describe reliability analysis for digital safety grade PLC (especially POSAFE-Q). Reliability analysis scope is Prediction, Calculation of MTBF (Mean Time Between Failure), FMEA (Failure Mode Effect Analysis), PFD (Probability of Failure on Demand). (author)

  6. Application of Kingview and PLC in friction durability test system

    Gao, Yinhan; Cui, Jing; Yang, Kaiyu; Ke, Hui; Song, Bing

    2013-01-01

    Using PLC and Kingview software, a friction durability test system is designed. The overall program, hardware configuration, software structure and monitoring interface are described in detail. PLC ensures the stability of data acquisition, and the KingView software makes the HMI easy to manipulate. The practical application shows that the proposed system is cheap, economical and highly reliable.

  7. Application of PLC in the crane control system of MJTR

    Li Ziqiang; Ji Xiangdong

    2004-01-01

    The paper describes the application of PLC (Programmable Controller) in the control system of the bridge crane. PLC is the essential part of the control system, which uses some equipment such as frequency transformer and photoelectric switch to implement remote, manual and automatic centering functions. This paper emphasizes the programming of the automatic hole centering

  8. Full-automatic Special Drill Hydraulic System and PLC Control

    Tian Xue Jun

    2016-01-01

    Full Text Available A hydraulic-driven and PLC full-automatic special drill is introduced, working principle of the hydraulic system and PLC control system are analyzed and designed, this equipment has the advantages of high efficiency, superior quality and low cost etc.

  9. Automatic production of Iodine-123 with PLC 135/U

    Moghaddam-Banaem, L.; Afarideh, H.

    2004-01-01

    In this project, the automatic system for production of Iodine-123 with PLC/135μ Siemens, which is designed and installed for the first time in Iran, is discussed. The PLC (Programmable Logic Controller) is used to control industrial processing, which is similar to a computer and consists of central processing unit and memory and Input/Output units. PLC receives input information from auxiliary units such as sensors, switches, etc. and software processes data in memory and then sends commands to output units such as relays, motors, etc.The target section in Iodine production consists of 8 stages. In order to be sure automation works properly the system can be operated both manually and automatically. First PLC checks Manual/Automatic switch and in the case of automatic mode, PLC runs the program in memory and processing is done automatically. For this purpose, PLC takes the value of pressures and temperatures from analog inputs and after processing them it sends commands to digital output to activate valves or vacuum pumps or heaters. In this paper the following subjects are discussed: 1) Production of Iodine 123 2) PLC structure and auxiliary boards 3) Sensors and actuators and their connection to PLC 4) Software flowchart

  10. Power line communications theory and applications for narrowband and broadband communications over power lines

    Ferreira, Hendrik C; Newbury, John; Swart, Theo G

    2010-01-01

    Power Line Communications (PLC) is a promising emerging technology, which has attracted much attention due to the wide availability of power distribution lines. This book provides a thorough introduction to the use of power lines for communication purposes, ranging from channel characterization, communications on the physical layer and electromagnetic interference, through to protocols, networks, standards and up to systems and implementations. With contributions from many of the most prominent international PLC experts from academia and industry, Power Line Communications brings togeth

  11. Aircraft Carriers

    Nødskov, Kim; Kværnø, Ole

    as their purchases of aircraft carrier systems, makes it more than likely that the country is preparing such an acquisition. China has territorial disputes in the South China Sea over the Spratly Islands and is also worried about the security of its sea lines of communications, by which China transports the majority......, submarines, aircraft and helicopters, is not likely to be fully operational and war-capable until 2020, given the fact that China is starting from a clean sheet of paper. The United States of America (USA), the United Kingdom (UK), Russia and India are currently building or have made decisions to build new...

  12. Conducted Interference Immunity Characteristics to High-speed Power Line Communication System

    Tokuda, Masamitsu; Hosoya, Satoshi; Yamagata, Toru; Matsuo, Takashi

    In this paper, we measured the immunity characteristics to the conducted interference wave, from the aspect of PHY rate (physical layer data rate) of PLC (Power Line Communication) system, and compared with simulation results by MATLAB/ Simulink. When the interference signal is impressed to the OFDM (Orthogonal Frequency Division Multiplexing) signal, the PHY rate decrease rapidly below C/I (Carrier / Interference) = 25dB and become nearly zero around C/I = -35dB, and so it turns out that the PLC System with OFDM signal has a good narrowband interference immunity characteristic. In addition, it is revealed that the PHY rate of PLC modem can be calculated by MATLAB/Simulink even when the narrowband interference signal is impressed through the power line. Furthermore, we examined the improving effect of the notch band for the immunity characteristics to the conducted interference wave. As a result, it is revealed that the PHY rate normalized by the maximum value increases by 15∼25% by inserting the notch when impressing the interference signal in the notch band and C/I is improved by 10∼15dB by inserting the notch.

  13. Development of a PLC modem for data transmission over a PWM power supply

    Batard, Christophe; Ginot, Nicolas; Mannah, Marc Anthony; Millet, Christophe; Poitiers, Frédéric

    2014-04-01

    In variable-speed electrical drive and online conditioning monitoring, a feedback loop is required in order to transmit the sensor information from the motor to the controller close to the inverter. Additional cabling is used for signalling. This extra cabling has a significant cost and data transmission may not be reliable. Thus, the use of power line communication (PLC) technology to transmit data in motor drive application is quite interesting. The use of a PLC modem dedicated to the home network in a three-phase inverter-fed motor power cable does not work. Therefore, specific coupling interfaces are developed to transmit data through a pulse-width modulated power supply. Laboratory tests have shown that the couplers are operating properly. They ensure reliable data transmission in a motor drive application.

  14. Enhanced Operation of Electricity Distribution Grids Through Smart Metering PLC Network Monitoring, Analysis and Grid Conditioning

    Iker Urrutia

    2013-01-01

    Full Text Available Low Voltage (LV electricity distribution grid operations can be improved through a combination of new smart metering systems’ capabilities based on real time Power Line Communications (PLC and LV grid topology mapping. This paper presents two novel contributions. The first one is a new methodology developed for smart metering PLC network monitoring and analysis. It can be used to obtain relevant information from the grid, thus adding value to existing smart metering deployments and facilitating utility operational activities. A second contribution describes grid conditioning used to obtain LV feeder and phase identification of all connected smart electric meters. Real time availability of such information may help utilities with grid planning, fault location and a more accurate point of supply management.

  15. Comportamiento de la Tecnología PLC en la Red Eléctrica

    García Guibout, J.; García Garino, Carlos; Fusario, Rubén J.; Castro Lechtaler, Antonio; Sevilla, Guillermo

    2007-01-01

    La tecnología PLC1 - PowerLine Communications- está referida a la transmisión de datos utilizando la red eléctrica, tanto domiciliaria, como la red de distribución de baja tensión. Dependiendo del tipo de red que se utilice como soporte esta tecnología se divide en PLC indoor y outdoor. La primera se refiere a la utilización de la red domiciliaria y utiliza las frecuencias más altas de 5 MHz a 30 ó 40 MHz. La segunda, outdoor, usa la red de distribución y las frecuencias bajas de 1 MHz a 5 ó ...

  16. Experimental Study of 6LoPLC for Home Energy Management Systems

    Augustine Ikpehai

    2016-12-01

    Full Text Available Ubiquitous connectivity is already transforming residential dwellings into smart homes. As citizens continue to embrace the smart home paradigm, a new generation of low-rate and low-power communication systems is required to leverage the mass market presented by energy management in homes. Although Power Line Communication (PLC technology has evolved in the last decade, the adaptation of PLC for constrained networks is not fully charted. By adapting some features of IEEE 802.15.4 and IPv6 over Low-power Wireless Personal Area Network (6LoWPAN into power lines, this paper demonstrates a low-rate, low-power PLC system over the IPv6 network (referred to as 6LoPLC, for Home Energy Management System (HEMS applications. The overall idea is to provide a framework for assessing various scenarios that cannot be easily investigated with the limited number of evaluation hardware available. In this respect, a network model is developed in NS-3 (Version 21 to measure several important characteristics of the designed system and then validated with experimental results obtained using the Hanadu evaluation kits. Following the good agreement between the two, the NS-3 model is utilised to investigate more complex scenarios and various use-cases, such as the effects of impulsive noise, the number of nodes and packet size on the latency and Bit Error Rate (BER performances. We further demonstrate that for different network and application configurations, optimal data sizes exist. For instance, the results reveal that in order to guarantee 99% system reliability, the HEMS application data must not exceed 64 bytes. Finally, it is shown that with impulsive noise in a HEMS network comprising 50 appliances, provided the size of the payload does not exceed 64 bytes, monitoring and control applications incur a maximum latency of 238.117 ms and 248.959 ms, respectively; both of which are within acceptable limits.

  17. Sealed substrate carrier for electroplating

    Ganti, Kalyana Bhargava [Fremont, CA

    2012-07-17

    One embodiment relates to a substrate carrier for use in electroplating a plurality of substrates. The substrate carrier includes a non-conductive carrier body on which the substrates are held, and conductive lines are embedded within the carrier body. A conductive bus bar is embedded into a top side of the carrier body and is conductively coupled to the conductive lines. A thermoplastic overmold covers a portion of the bus bar, and there is a plastic-to-plastic bond between the thermoplastic overmold and the non-conductive carrier body. Other embodiments, aspects and features are also disclosed.

  18. Maintainable substrate carrier for electroplating

    Chen, Chen-An [Milpitas, CA; Abas, Emmanuel Chua [Laguna, PH; Divino, Edmundo Anida [Cavite, PH; Ermita, Jake Randal G [Laguna, PH; Capulong, Jose Francisco S [Laguna, PH; Castillo, Arnold Villamor [Batangas, PH; Ma,; Xiaobing, Diana [Saratoga, CA

    2012-07-17

    One embodiment relates to a substrate carrier for use in electroplating a plurality of substrates. The carrier includes a non-conductive carrier body on which the substrates are placed and conductive lines embedded within the carrier body. A plurality of conductive clip attachment parts are attached in a permanent manner to the conductive lines embedded within the carrier body. A plurality of contact clips are attached in a removable manner to the clip attachment parts. The contact clips hold the substrates in place and conductively connecting the substrates with the conductive lines. Other embodiments, aspects and features are also disclosed.

  19. Development of an In-Line Minority-Carrier Lifetime Monitoring Tool for Process Control during Fabrication of Crystalline Silicon Solar Cells: Annual Subcontract Report, June 2003 (Revised)

    Sinton, R. A.

    2004-04-01

    Under the PV Manufacturing R&D subcontract''Development of an In-Line, Minority-Carrier Lifetime Monitoring Tool for Process Control during Fabrication of Crystalline Silicon Solar Cells'', Sinton Consulting developed prototypes for several new instruments for use in the manufacture of silicon solar cells. These instruments are based on two families of R&D instruments that were previously available, an illumination vs. open-circuit-voltage technique and the quasi-steady state RF photoconductance technique for measuring minority-carrier lifetime. Compared to the previous instruments, the new prototypes are about 20 times faster per measurement, and have automated data analysis that does not require user intervention even when confronted by challenging cases. For example, un-passivated multi-crystalline wafers with large variations in lifetime and trapping behavior can be measured sequentially without error. Five instruments have been prototyped in this project to date, including a block tester for evaluating cast or HEM silicon blocks, a CZ ingot tester, an FZ boule tester for use with long-lifetime silicon, and an in-line sample head for measuring wafers. The CZ ingot tester and the FZ boule tester are already being used within industry and there is interest in the other prototypes. For each instrument, substantial R&D work was required in developing the device physics and analysis as well as for the hardware. This work has been documented in a series of application notes and conference publications, and will result in significant improvements for both the R&D and the industrial types of instruments.

  20. PLC-controlled cryostats for the BlackGEM and MeerLICHT detectors

    Raskin, Gert; Morren, Johan; Pessemier, Wim; Bloemen, Steven; Klein-Wolt, Marc; Roelfsema, Ronald; Groot, Paul; Aerts, Conny

    2016-08-01

    BlackGEM is an array of telescopes, currently under development at the Radboud University Nijmegen and at NOVA (Netherlands Research School for Astronomy). It targets the detection of the optical counterparts of gravitational waves. The first three BlackGEM telescopes are planned to be installed in 2018 at the La Silla observatory (Chile). A single prototype telescope, named MeerLICHT, will already be commissioned early 2017 in Sutherland (South Africa) to provide an optical complement for the MeerKAT radio array. The BlackGEM array consists of, initially, a set of three robotic 65-cm wide-field telescopes. Each telescope is equipped with a single STA1600 CCD detector with 10.5k x 10.5k 9-micron pixels that covers a 2.7 square degrees field of view. The cryostats for housing these detectors are developed and built at the KU Leuven University (Belgium). The operational model of BlackGEM requires long periods of reliable hands-off operation. Therefore, we designed the cryostats for long vacuum hold time and we make use of a closed-cycle cooling system, based on Polycold PCC Joule-Thomson coolers. A single programmable logic controller (PLC) controls the cryogenic systems of several BlackGEM telescopes simultaneously, resulting in a highly reliable, cost-efficient and maintenance-friendly system. PLC-based cryostat control offers some distinct advantages, especially for a robotic facility. Apart of temperature monitoring and control, the PLC also monitors the vacuum quality, the power supply and the status of the PCC coolers (compressor power consumption and temperature, pressure in the gas lines, etc.). Furthermore, it provides an alarming system and safe and reproducible procedures for automatic cool down and warm up. The communication between PLC and higher-level software takes place via the OPC-UA protocol, offering a simple to implement, yet very powerful interface. Finally, a touch-panel display on the PLC provides the operator with a user-friendly and robust

  1. Modeling a Consistent Behavior of PLC-Sensors

    E. V. Kuzmin

    2014-01-01

    Full Text Available The article extends the cycle of papers dedicated to programming and verificatoin of PLC-programs by LTL-specification. This approach provides the availability of correctness analysis of PLC-programs by the model checking method.The model checking method needs to construct a finite model of a PLC program. For successful verification of required properties it is important to take into consideration that not all combinations of input signals from the sensors can occur while PLC works with a control object. This fact requires more advertence to the construction of the PLC-program model.In this paper we propose to describe a consistent behavior of sensors by three groups of LTL-formulas. They will affect the program model, approximating it to the actual behavior of the PLC program. The idea of LTL-requirements is shown by an example.A PLC program is a description of reactions on input signals from sensors, switches and buttons. In constructing a PLC-program model, the approach to modeling a consistent behavior of PLC sensors allows to focus on modeling precisely these reactions without an extension of the program model by additional structures for realization of a realistic behavior of sensors. The consistent behavior of sensors is taken into account only at the stage of checking a conformity of the programming model to required properties, i. e. a property satisfaction proof for the constructed model occurs with the condition that the model contains only such executions of the program that comply with the consistent behavior of sensors.

  2. Trends in Control Area of PLC Reliability and Safety Parameters

    Juraj Zdansky

    2008-01-01

    Full Text Available Extension of the PLC application possibilities is closely related to increase of reliability and safety parameters. If the requirement of reliability and safety parameters will be suitable, the PLC could by implemented to specific applications such the safety-related processes control. The goal of this article is to show the way which producers are approaching to increase PLC`s reliability and safety parameters. The second goal is to analyze these parameters for range of present choice and describe the possibility how the reliability and safety parameters can be affected.

  3. Analysis of the PLC object model in the PF linac

    Abe, Isamu; Shirakawa, Akihiro; Nakahara, Kazuo; Tanaka, Masahiko

    1995-01-01

    Device controllers (front end) for the KEK PF Linac, which has been operated for more than ten years, had to be renewed, because there is no longer support from hardware manufacturer. To reduce maintenance costs, device controllers are planed to be replaced by PLC (Programmable Logic Controller). Investigations launched in the late 1994s for the PLC have carried out in order to make sure of the I/O stability and network possibilities. In this paper, the software for the PLC is discussed based on the OOP concept. (author)

  4. Estudio para la automatización de la lectura, corte y reconexión de la energía eléctrica mediante tecnología PLC (Power Line Communication). Caso de análisis : Empresa Eléctrica Regional CentroSur C.A.

    Quizhpi Montero, Diego Armando; Ruiz Orellana, José Luis

    2007-01-01

    La finalidad de esta tesis es entregar una mayor información sobre la tecnología PLC, como sus bases teóricas y de cómo aprovecha el tendido de red eléctrica para la lectura, corte y reconexión de los contadores de energía eléctrica mediante la utilización de equipos adecuados. La tecnología PLC también permite ofrecer una diversidad de servicios de telecomunicaciones, tales como: voz, video y datos, el cual se lo conoce como triple-play. Al momento de transmitir datos por el tendido el...

  5. Applying Model Checking to Industrial-Sized PLC Programs

    AUTHOR|(CDS)2079190; Darvas, Daniel; Blanco Vinuela, Enrique; Tournier, Jean-Charles; Bliudze, Simon; Blech, Jan Olaf; Gonzalez Suarez, Victor M

    2015-01-01

    Programmable logic controllers (PLCs) are embedded computers widely used in industrial control systems. Ensuring that a PLC software complies with its specification is a challenging task. Formal verification has become a recommended practice to ensure the correctness of safety-critical software but is still underused in industry due to the complexity of building and managing formal models of real applications. In this paper, we propose a general methodology to perform automated model checking of complex properties expressed in temporal logics (\\eg CTL, LTL) on PLC programs. This methodology is based on an intermediate model (IM), meant to transform PLC programs written in various standard languages (ST, SFC, etc.) to different modeling languages of verification tools. We present the syntax and semantics of the IM and the transformation rules of the ST and SFC languages to the nuXmv model checker passing through the intermediate model. Finally, two real cases studies of \\CERN PLC programs, written mainly in th...

  6. Programmable logic controller (PLC) for safety systems of nuclear plants

    Sen, S.K.; Karmakar, G.; Joseph, Jose; Patil, R.K.

    2002-01-01

    Full text: A programmable logic controller (PLC) has been developed by RCnD, BARC for use in the safety critical systems in nuclear power plants. This PLC uses qualified hardware developed in RCnD for use in NPP. The programming software conforms to IEC-61131 part 3. The application programming is done on function block diagram (FBD) editor and the FBD is automatically converted into code in high level language (C / C++). This feature makes the application easily decipherable and therefore easily subjected to reviews and other validation techniques. The key to make quality software for use in nuclear systems is to enforce various standards in the design and development of the software, something, which is not possible to do with a commercially available PLC. This PLC with its software completely transparent lends itself to rigorous verification and validation easily

  7. Voltage Control System of A DC Generator Using PLC

    Subrata CHATTOPADHYAY; Sagarika PAL

    2008-01-01

    The voltage control system of a DC generator may suffer from high frequency oscillations without offset or low frequency oscillation with offset. A PID controller can eliminate both these errors. In the present paper, the voltage control system of a DC generator using a PLC based PID controller has been designed. Operation of PLC as a continuous controller has been described and the load characteristic of DC generator with and without controller have been determined experimentally and reporte...

  8. Towards Designing PLC Networks for Ubiquitous Connectivity in Enterprises

    Ali, Kamran; Pefkianakis, Ioannis; Liu, Alex X.; Kim, Kyu-Han

    2016-01-01

    Powerline communication (PLC) provides inexpensive, secure and high speed network connectivity, by leveraging the existing power distribution networks inside the buildings. While PLC technology has the potential to improve connectivity and is considered a key enabler for sensing, control, and automation applications in enterprises, it has been mainly deployed for improving connectivity in homes. Deploying PLCs in enterprises is more challenging since the power distribution network is more com...

  9. Zerumbone-loaded nanostructured lipid carrier induces G2/M cell cycle arrest and apoptosis via mitochondrial pathway in a human lymphoblastic leukemia cell line

    Rahman HS

    2014-01-01

    Full Text Available Heshu Sulaiman Rahman,1–3 Abdullah Rasedee,1,2 Ahmad Bustamam Abdul,2,4 Nazariah Allaudin Zeenathul,1,2 Hemn Hassan Othman,1,3 Swee Keong Yeap,2 Chee Wun How,2 Wan Abd Ghani Wan Nor Hafiza4,51Faculty of Veterinary Medicine, 2Institute of Bioscience, Universiti Putra Malaysia, Selangor, Malaysia; 3Faculty of Veterinary Medicine, University of Sulaimanyah, Sulaimanyah City, Kurdistan Region, Northern Iraq; 4Faculty of Medicine and Health Science, Universiti Putra Malaysia, Selangor, Malaysia; 5College of Medical Laboratory Technology, Institute for Medical Research, Kuala Lumpur, MalaysiaAbstract: This investigation evaluated the antileukemia properties of a zerumbone (ZER-loaded nanostructured lipid carrier (NLC prepared by hot high-pressure homogenization techniques in an acute human lymphoblastic leukemia (Jurkat cell line in vitro. The apoptogenic effect of the ZER-NLC on Jurkat cells was determined by fluorescent and electron microscopy, Annexin V-fluorescein isothiocyanate, Tdt-mediated dUTP nick-end labeling assay, cell cycle analysis, and caspase activity. An MTT (3-(4,5-dimethylthiazol-2-yl-2,5 diphenyltetrazolium bromide assay showed that ZER-NLC did not have adverse effects on normal human peripheral blood mononuclear cells. ZER-NLC arrested the Jurkat cells at G2/M phase with inactivation of cyclin B1 protein. The study also showed that the antiproliferative effect of ZER-NLC on Jurkat cells is through the intrinsic apoptotic pathway via activation of caspase-3 and caspase-9, release of cytochrome c from the mitochondria into the cytosol, and subsequent cleavage of poly (adenosine diphosphate-ribose polymerase (PARP. These findings show that the ZER-NLC is a potentially useful treatment for acute lymphoblastic leukemia in humans.Keywords: zerumbone-loaded nanostructured lipid carrier, cell cycle arrest, apoptosis, mitochondrial pathway

  10. Safety culture development in nuclear electric plc

    Gibson, G.P.; Low, M.B.J.

    1995-01-01

    Nuclear Electric plc (NE) has always given the highest priority to safety. However, past emphasis has been directed towards ensuring safety thorough engineering design and hazard control procedures. Whilst the company did achieve high safety standards, particularly with respect to accidents, it was recognized that further improvements could be obtained. Analysis of the safety performance across a wide range of industries showed that the key to improving safety performance lay in developing a strong safety culture within the company. Over the last five years, NE has made great strides to improve its safety culture. This has resulted in a considerable improvement in its measured safety performance indicators, such as the number of incidents at international nuclear event scale (INES) rating 1, the number of lost time accidents and the collective radiation dose. However, despite this success, the company is committed to further improvement and a means by which this process becomes self-sustaining. In this way the company will achieve its prime goal, to ''ensure the safety of people, plant and the environment''. The paper provides an overview of the development of safety culture in NE since its formation in November 1989. It describes the research and international developments that have influenced the company's understanding of safety culture, the key initiatives that the company has undertaken to enhance its safety culture and the future initiatives being considered to ensure continual improvement. (author). 5 refs, 2 figs, 2 tabs

  11. Implementation of RS-485 Communication between PLC and PC of Distributed Control System Based on VB

    Lian Zhang, Chuan; Da Huang, Zhi; Qing Zhou, Gui; Chong, Kil To

    2015-05-01

    This paper focuses on achieving RS-485 communication between programmable logical controller (PLC) and PC based on visual basic 6.0 (VB6.0) on an experimental automatic production line. Mitsubishi FX2N PLCs and a PC are chosen as slave stations and main station, respectively. Monitoring software is developed using VB6.0 for data input/output, flow control and online parameters setting. As a result, all functions are fulfilled with robust performance. It is concluded from results that one PC can monitor several PLCs using RS-485 communication.

  12. Silencing of the tomato phosphatidylinositol-phospholipase C2 (SlPLC2) reduces plant susceptibility to Botrytis cinerea

    Gonorazky, Gabriela; Guzzo, María Carla; Abd-El-Haliem, Ahmed M.; Joosten, Matthieu H.A.J.; Laxalt, Ana María

    2016-01-01

    The tomato [Solanum lycopersicum (Sl)] phosphatidylinositol-phospholipase C (PI-PLC) gene family is composed of six members, named SlPLC1 to SlPLC6, differentially regulated on pathogen attack. We have previously shown that the fungal elicitor xylanase induces a raise of SlPLC2 and SlPLC5

  13. Data acquisition and control system with a programmable logic controller (PLC) for a pulsed chemical oxygen-iodine laser

    Yu, Haijun; Li, Guofu; Duo, Liping; Jin, Yuqi; Wang, Jian; Sang, Fengting; Kang, Yuanfu; Li, Liucheng; Wang, Yuanhu; Tang, Shukai; Yu, Hongliang

    2015-02-01

    A user-friendly data acquisition and control system (DACS) for a pulsed chemical oxygen -iodine laser (PCOIL) has been developed. It is implemented by an industrial control computer,a PLC, and a distributed input/output (I/O) module, as well as the valve and transmitter. The system is capable of handling 200 analogue/digital channels for performing various operations such as on-line acquisition, display, safety measures and control of various valves. These operations are controlled either by control switches configured on a PC while not running or by a pre-determined sequence or timings during the run. The system is capable of real-time acquisition and on-line estimation of important diagnostic parameters for optimization of a PCOIL. The DACS system has been programmed using software programmable logic controller (PLC). Using this DACS, more than 200 runs were given performed successfully.

  14. LINES

    Minas Bakalchev

    2015-10-01

    Full Text Available The perception of elements in a system often creates their interdependence, interconditionality, and suppression. The lines from a basic geometrical element have become the model of a reductive world based on isolation according to certain criteria such as function, structure, and social organization. Their traces are experienced in the contemporary world as fragments or ruins of a system of domination of an assumed hierarchical unity. How can one release oneself from such dependence or determinism? How can the lines become less “systematic” and forms more autonomous, and less reductive? How is a form released from modernistic determinism on the new controversial ground? How can these elements or forms of representation become forms of action in the present complex world? In this paper, the meaning of lines through the ideas of Le Corbusier, Leonidov, Picasso, and Hitchcock is presented. Spatial research was made through a series of examples arising from the projects of the architectural studio “Residential Transformations”, which was a backbone for mapping the possibilities ranging from playfulness to exactness, as tactics of transformation in the different contexts of the contemporary world.

  15. Users` demands narrow PLC-DCS gap

    La Fauci, J.

    1997-02-01

    Supervisory control and data acquisition (SCADA) operator interface (OI) software has propelled programmable logic controllers (PLCs) into areas where they can successfully compete with distributed control systems (DCSs) for many control applications. As a result, automation engineers are struggling to develop guidelines to help determine which is best for batch operations and other applications. There is no clear answer to this issue. There are, however, decision tools such as Kepner-Tregoe (K-T) that can be applied by engineers as a structured approach to decision analysis and system selection. Other factors such as business environment, pressure to reduce project cost, validation, and predicting new technology direction all play a critical role for engineers in choosing between a PLC- or DCS-based control system. Higher-level business issues, however, are seldom considered by engineers during control system selection. Engineers should try to better understand their company`s business objectives and mission statement and how company business direction may affect control system selection. For instance, the pharmaceutical industry can be broken up into the following five basic application groups: bulk chemicals, finishing, biotech, pilot plant, and utilities. Each has a unique set of functional and process-control requirements. Understanding needs and differences of these five basic application groups and applying the optimum control system solution will place the company in a more competitive position. A financial analysis should be one of the first steps in the control system evaluation process. This may include early agreement of contractual terms and conditions as well as a nondisclosure agreement. Other financial considerations may include requesting a financial report on the control system manufacturer or systems integrator that will be performing the work to determine its financial stability. 3 figs.

  16. Performance analysis of OFDM modulation on indoor broadband PLC channels

    Antonio Cortés, José; Díez, Luis; Cañete, Francisco Javier; Sánchez-Martínez, Juan José; Entrambasaguas, José Tomás

    2011-12-01

    Indoor broadband power-line communications is a suitable technology for home networking applications. In this context, orthogonal frequency-division multiplexing (OFDM) is the most widespread modulation technique. It has recently been adopted by the ITU-T Recommendation G.9960 and is also used by most of the commercial systems, whose number of carriers has gone from about 100 to a few thousands in less than a decade. However, indoor power-line channels are frequency-selective and exhibit periodic time variations. Hence, increasing the number of carriers does not always improves the performance, since it reduces the distortion because of the frequency selectivity, but increases the one caused by the channel time variation. In addition, the long impulse response of power-line channels obliges to use an insufficient cyclic prefix. Increasing its value reduces the distortion, but also the symbol rate. Therefore, there are optimum values for both modulation parameters. This article evaluates the performance of an OFDM system as a function of the number of carriers and the cyclic prefix length, determining their most appropriate values for the indoor power-line scenario. This task must be accomplished by means of time-consuming simulations employing a linear time-varying filtering, since no consensus on a tractable statistical channel model has been reached yet. However, this study presents a simpler procedure in which the distortion because of the frequency selectivity is computed using a time-invariant channel response, and an analytical expression is derived for the one caused by the channel time variation.

  17. Prototype of Automated PLC Model Checking Using Continuous Integration Tools

    Lettrich, Michael

    2015-01-01

    To deal with the complexity of operating and supervising large scale industrial installations at CERN, often Programmable Logic Controllers (PLCs) are used. A failure in these control systems can cause a disaster in terms of economic loses, environmental damages or human losses. Therefore the requirements to software quality are very high. To provide PLC developers with a way to verify proper functionality against requirements, a Java tool named PLCverif has been developed which encapsulates and thus simplifies the use of third party model checkers. One of our goals in this project is to integrate PLCverif in development process of PLC programs. When the developer changes the program, all the requirements should be verified again, as a change on the code can produce collateral effects and violate one or more requirements. For that reason, PLCverif has been extended to work with Jenkins CI in order to trigger automatically the verication cases when the developer changes the PLC program. This prototype has been...

  18. Voltage Control System of A DC Generator Using PLC

    Subrata CHATTOPADHYAY

    2008-06-01

    Full Text Available The voltage control system of a DC generator may suffer from high frequency oscillations without offset or low frequency oscillation with offset. A PID controller can eliminate both these errors. In the present paper, the voltage control system of a DC generator using a PLC based PID controller has been designed. Operation of PLC as a continuous controller has been described and the load characteristic of DC generator with and without controller have been determined experimentally and reported in this paper.

  19. Transforming PLC Programs into Formal Models for Verification Purposes

    Darvas, D; Blanco, E

    2013-01-01

    Most of CERN’s industrial installations rely on PLC-based (Programmable Logic Controller) control systems developed using the UNICOS framework. This framework contains common, reusable program modules and their correctness is a high priority. Testing is already applied to find errors, but this method has limitations. In this work an approach is proposed to transform automatically PLC programs into formal models, with the goal of applying formal verification to ensure their correctness. We target model checking which is a precise, mathematical-based method to check formalized requirements automatically against the system.

  20. Model-based automated testing of critical PLC programs.

    Fernández Adiego, B; Tournier, J-C; González Suárez, V M; Bliudze, S

    2014-01-01

    Testing of critical PLC (Programmable Logic Controller) programs remains a challenging task for control system engineers as it can rarely be automated. This paper proposes a model based approach which uses the BIP (Behavior, Interactions and Priorities) framework to perform automated testing of PLC programs developed with the UNICOS (UNified Industrial COntrol System) framework. This paper defines the translation procedure and rules from UNICOS to BIP which can be fully automated in order to hide the complexity of the underlying model from the control engineers. The approach is illustrated and validated through the study of a water treatment process.

  1. Development and Application of POSAFE-Q PLC Platform

    Lee, MyeongKyun; Song, SeungWhan; Yun, DongHwa

    2012-01-01

    The Safety-grade Programmable Logic Controller (PLC) Platform named POSAFE-Q was developed so that it meets the requirements of the Safety Class 1E, Quality Class 1, and Seismic Category I. Development process of the POSAFE-Q software developed in accordance with software life cycles. The POSAFE-Q meets safety and suitability for design are based on digital I and C laws, guidelines and technical standards. The POSAFE-Q PLC obtained approval for Topical Report from the Nuclear Safety and Security Commission in Korea. (author)

  2. 77 FR 6668 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2012-02-09

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... all Rolls-Royce plc RB211-Trent 500 series turbofan engines. This AD requires a one-time inspection of... RB211- Trent 560A2-61 turbofan engines that have not complied with Rolls- Royce plc Service Bulletin No...

  3. 78 FR 11976 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-02-21

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... (AD) for all Rolls-Royce plc (RR) RB211-524 series turbofan engines. That AD currently requires...-16724 (76 FR 40217, July 8, 2011), for all RR plc RB211-524 series turbofan engines. That AD required...

  4. Study of carrier mobility of N,N′-diphenyl-N,N′bis(1,1′-biphenyl)-4,4′-diamine (NPB) by transmission line model of impedance spectroscopy

    Tang, Chao; Xu, Hui; Wang, Xu-Liang; Liu, Wei; Liu, Rui-Lan; Rong, Zhou; Fan, Qu-Li; Huang, Wei

    2013-01-01

    As a powerful method for electrical measurement, impedance spectroscopy and admittance spectroscopy methods began to receive more and more attention in organic electronics research scholars. It demonstrates outstanding advantages especially in the measurement of the mobility of the charge carriers. In this paper, the hole mobility of N,N′-diphenyl-N,N′bis(1,1′-biphenyl)-4,4′-diamine (NPB) was studied by the transmission line model based on impedance spectroscopy. According to energy level of the materials of each layer, a hole-only current device with single-layer structure of indium-tin-oxide(ITO)/NPB/Ag was designed and fabricated, and its Nyquist diagram was measured at different biased voltage. The corresponding transmission line model was proposed according to the device structure and the materials, which was used to the fitting procedure to get the transfer time of the carrier. At last, the carrier mobility was obtained from the transfer time. The results showed that the hole mobility of NPB obtained by transmission line model was in line with the Poole–Freckle model. The zero-field mobility and the pre-exponential factor was further achieved to be 3.9 × 10 −5 cm 2 · V −1 · s −1 and 6.8 × 10 −3 (V/cm) −1/2 , respectively. Moreover, the method can also be easily used for the study of the electron transport properties of the organic semiconductor. - Highlights: • Hole mobility of N,N′-diphenyl-N,N′bis(1,1′-biphenyl)-4,4′-diamine (NPB) was studied by the transmission line model • The results was in line with the Poole-Freckle model • Zero-field mobility and the pre-exponential factor was further achieved

  5. Integration of the HVCM PLC into the PEFP Control System

    Song, Young Gi; Jang, Ji Ho; Kwon, Hyeok Jung; Cho, Yong Sub

    2011-01-01

    The High Voltage Converter Modulators (HVCM) for the 100-MeV accelerator was installed to drive the 20-MeV linac. There are two klystrons in the 20-MeV linac and one modulator was used to drive two klystrons simultaneously. The HVCM for the 20-MeV linac area in Korea Atomic Energy Research Institute (KAERI) is shown in Fig. 1. We were faced with the necessity of integrating Programmable Logic Controllers (PLCs) for the HVCM into the Proton Engineering Frontier Project (PEFP) control system. At the PEFP, Experimental Physics and Industrial Control System (EPICS) has become the most widely used solution for building control systems for 100MeV proton accelerator. The EPICS as a standard development tool is a distributed architecture that provides several solutions such as independent programming tools for operating system, operator interface tools, and archiving tools. Although EPICS is used directly in our control system, HVCMs were delivered with the Allen-Bradley ControlLogix as a PLC. The industrial PLC has been verified for safety systems. We need to connect an interface from our EPICS control system to AB-PLC using Ethernet/IP (ControlNet over Ethernet) protocol over Ethernet. In this paper, we will present the communication protocol and EPICS IOC installation for the EPICS based PLC control system

  6. PowerGen plc report and accounts 1994

    1994-01-01

    The annual report and accounts of PowerGen plc for the year 1994 are presented. Financial highlights are quoted, followed by the Chairman's statement, reviews by the Chief Executive and Financial Directors, reports by the Auditors and Directors, balance sheets and details of the consolidated profit and loss account and principal accounting policies. A four year summary and shareholder information are included. (UK)

  7. Multiprog Virtual Laboratory Applied to PLC Programming Learning

    Shyr, Wen-Jye

    2010-01-01

    This study develops a Multiprog virtual laboratory for a mechatronics education designed to teach how to programme a programmable logic controller (PLC). The study was carried out with 34 students in the Department of Industry Education and Technology at National Changhua University of Education in Taiwan. In total, 17 students were assigned to…

  8. Analysis and modeling of low voltage electrical network at power line carrier frequencies (3-148.5 kHz); Analyse et modelisation du reseau basse tension aux frequences courants porteurs (3 KHZ-148,5 KHZ)

    Duval, G.

    1998-07-01

    Electricite de France (EdF) wishes to establish a physical communication link between his clients and the EdF centres. The final link, i.e. between the high/low voltage transformation substation and the residential clients, being ensured by carrier currents. With this aim, an analysis and a modeling of the low voltage network at the carrier frequencies (3 kHz - 148.5 kHz) has been performed. This work has been carried out in parallel with an experiment involving 3500 apparatuses that use carrier currents. The diversity of the French low voltage networks and the limitations imposed by the EN50065-1 standard about the use of carrier currents in Europe do not favour the development of such carrier current systems. Disturbing voltages and localized impedances represent the main difficulties to get round. Inside accommodations, domotic carrier currents have a reduced range but a higher disturbance amplitude because of the proximity of appliances. A differential mode to common mode conversion phenomenon has been evidenced which generates network couplings and important electromagnetic fields. Energy lines and cables have been analyzed using numerical models. Load peaks have been analyzed using statistical tools in order to take into account the daily fluctuations. The modeling of the network is made in two steps: a double-wire model is considered first. Then a three-phase model is developed which analyzes the inter-phases coupling and the effect of the distribution of clients' loads on each phase. The results of this model are conformable with measurements except for underground networks. As perspectives of future works and beyond todays standard framework, the techniques that allow a sensible increase of communication flow rates have been reviewed. (J.S.)

  9. Úzkopásmová PLC komunikace se standardy G3-PLC, PRIME a IEEE-1901.2

    Skrášek, Tomáš

    2015-01-01

    Diplomová práce pojednává o standardech úzkopásmové PLC komunikace. V teoretické části jsou popsány všechny dostupné OFDM standardy, mezi něž patří G3-PLC, PRIME, IEEE-1901.2 a G.hnem. Praktická část se zabývá standardy PRIME a G3-PLC. Dále je také porovnán systém OFDM se systémem komunikace na jedné nosné frekvenci v prostředí s reálným rušením. V poslední části je popsán návrh dvou firmware pro PLC modemy Texas Instruments TMDSPLCKIT-V3, které umožňují UART komunikaci a dálkový sběr dat. K ...

  10. Προσδιορισμός της απόδοσης αγωγών υψηλής τάσης για τη χρήση PowerLine Communication (PLC)

    Μουστάκα, Μαρία; Σταμούλη, Αλεξία

    2011-01-01

    Ο στόχος της διπλωματικής αυτής είναι η περιγραφή της αναδυόμενης τεχνολογίας PLC (PowerLine Communication). Η τεχνολογία αυτή με τη χρήση του πανταχού παρόντος ηλεκτρικού δικτύου προσφέρει ακόμα και σε απομακρυσμένους χρήστες πληθώρα ευρυζωνικών υπηρεσιών και πρόσβαση στο διαδίκτυο, αποτελώντας μια ανταγωνιστική επιλογή τρόπου επικοινωνίας. Για την κατανόηση της PLC τεχνολογίας αρχικά κρίνουμε απαραίτητη την λεπτομερή περιγραφή της δομής του ηλεκτρικού δικτύου, του εξοπλισμού που απαιτείται ...

  11. Doxorubicin bound to a HPMA copolymer carrier through hydrazone bond is effective also in a cancer cell line with a limited content of lysosomes

    Říhová, Blanka; Etrych, Tomáš; Pechar, Michal; Jelínková, Markéta; Šťastný, Marek; Hovorka, Ondřej; Kovář, Marek; Ulbrich, Karel

    2001-01-01

    Roč. 74, - (2001), s. 225-232 ISSN 0168-3659 R&D Projects: GA MZd NC5050; GA ČR GV307/96/K226 Institutional research plan: CEZ:AV0Z5020903 Keywords : HPMA copolymer carrier * proteolytically cleavable bond Subject RIV: EC - Immunology Impact factor: 2.626, year: 2001

  12. Radionuclide carrier

    Hartman, F.A.; Kretschmar, H.C.; Tofe, A.J.

    1978-01-01

    A physiologically acceptable particulate radionuclide carrier is described. It comprises a modified anionic starch derivative with 0.1% to 1.5% by weight of a reducing agent and 1 to 20% by weight of anionic substituents

  13. Carrier Screening

    ... How accurate is carrier screening? No test is perfect. In a small number of cases, test results ... in which an egg is removed from a woman’s ovary, fertilized in a laboratory with the man’s ...

  14. Realization of PLC to the Variable Frequency Speed Regulation System of Mine Local Ventilator based on RS-485 Communication

    Ma, Kai; Li, Jian; Yun, Yichong

    2018-03-01

    The article first introduces the merits of serial communication in the PLC to the variable frequency speed regulation system of mine local ventilator, and then sets up a hardware application development platform of PLC and inverter based on RS-485 communication technology, next presents communication initialization of the PLC and Inverter. Finally according to the control requirements, PLC send run operation & monitoring instruction to Inverter, realizes the serial communication control between the PLC and Inverter.

  15. Development of the safety PLC for plant protection system

    Kim, Chang Hwoi; Lee, Dong Young [Korea Atomic Energy Research Institute, Taejeon (Korea, Republic of)

    2005-11-15

    The safety PLC (POSAFE-Q) is developing in the Korea Nuclear Instrumentation and Control System (KNICS) R and D project. The PLC satisfies Safety Class 1E, Quality Class 1, and Seismic Category I. The software such as RTOS and firmware are developed according to safety critical software life cycle. Especially, the formal method is applied to design SRS (Software Requirement Spec.) and SDS (Software Design Specification.) for error-free. The developed software according to software life cycle is verified by independent software V and V team. The overall response time from an input to the outputs shall be 50ms or less. The prototype for the POSAFE-Q was developed and functional testing and equipment qualification tests have been underway.

  16. Bringing Automated Formal Verification to PLC Program Development

    Fernández Adiego, Borja; Blanco Viñuela, Enrique

    Automation is the field of engineering that deals with the development of control systems for operating systems such as industrial processes, railways, machinery or aircraft without human intervention. In most of the cases, a failure in these control systems can cause a disaster in terms of economic losses, environmental damages or human losses. For that reason, providing safe, reliable and robust control systems is a first priority goal for control engineers. Ideally, control engineers should be able to guarantee that both software and hardware fulfill the design requirements. This is an enormous challenge in which industry and academia have been working and making progresses in the last decades. This thesis focuses on one particular type of control systems that operates industrial processes, the PLC (Programmable Logic Controller) - based control systems. Moreover it targets one of the main challenges for these systems, guaranteeing that PLC programs are compliant with their specifications. Traditionally ...

  17. British Nuclear Fuels plc: report and accounts 1987-88

    1989-01-01

    The Energy Committee has considered the report and accounts of BNFL (British Nuclear Fuels PLC) for the year 1987-88. The report looks at BNFL as a government owned PLC - its activities and financial performance. Various questions are raised about the underlying financial position justifying the optimism portrayed in the report and accounts. The impact of cost-plus contracts on UK customers is examined. The economics of THORP (Thermal Oxide Reprocessing Plant) are also examined especially as the escalation in the cost of constructing THORP means that a substantial loss will be made in the reprocessing of waste for which contracts were signed in the late 1960s or early 1970s. The main conclusions of the report are summarized. One of these is that the UK must be cautious about becoming a repository of foreign nuclear waste. Other specific recommendations are made - some about the decommissioning of BNFL plant. (UK)

  18. Implementation of PID autotuning procedure in PLC controller

    Daniun Marcin

    2017-01-01

    Full Text Available In this paper, we present the automatic PID tuning procedure based on the Method of Moments and AMIGO tuning rules. The advantage of the Method of Moments is that the time constant and transport delay are estimated at the areas rather than on the individual points. This results in high resistance to the measurement noises. The sensitivity to measurement noises is a serious problem in other autotuning methods. The second advantage of this method is that it approximates plant during identification process to first order model with time delay. We combined the Method of Moments with the AMIGO tuning rules and implemented this combination as a stand-alone autotuning procedure in Siemens S7-1200 PLC controller. Next, we compared this method with two built-in PID autotuning procedures which were available in Siemens S7-1200 PLC controller. The procedure was tested for three types of plant models: with lag-dominated, balanced, and delay-dominated dynamics. We simulated the plants on a PC in Matlab R2013a. The connection between the PC and PLC was maintained through a National Instruments data acquisition board, NI PCI-6229. We conducted tests for step change in the set point, trajectory tracking, and load disturbances. To assess control quality, we used IAE index. We limited our research to PI algorithm. The results prove that proposed method was better than two built-in tuning methods provided by Siemens, oscillating between a few and even a dozen percent in most cases. The proposed method is universal and can be implemented in any PLC controller.

  19. Fifth Baltic Sea pollution load compilation (PLC-5)

    Knuuttila, S.; Svendsen, L. M.; Staaf, H.; Kotilainen, P.; Boutrup, S.; Pyhala, M.; Durkin, M.

    2011-07-01

    This report includes the main results from the Fifth Pollution Load Compilation abbreviated PLC-5. It includes quantified annual waterborne total loads (from rivers, unmonitored and coastal areas as well as direct point and diffuse sources discharging directly to the Baltic Sea) from 1994 to 2008 to provide a basis for evaluating any decreasing (or increasing) trends in the total waterborne inputs to the Baltic Sea. Chapter 1 contains the objectives of PLC and the framework on classification of inputs and sources. Chapter 2 includes a short description of the Baltic Sea catchment area, while the methods for quantification and analysis together with quality assurance topics are briefly introduced in Chapter 3. More detailed information on methodologies is presented in the PLC-5 guidelines (HELCOM 2006). Chapter 4 reports the total inputs to the Baltic Sea of nutrients and selected heavy metals. Furthermore, the results of the quatification of discharges and losses of nitrogen and phosphorus from point and diffuse sources into inland surface waters within the Baltic Sea catchment area (source-oriented approach or gross loads) as well as the total load to the maritime area (load-oriented approarch or net loads) in 2006 are shown. Typically, results are presented by country and by main Baltic Sea sub-region. In Chapter 5, flow normalization is introduced and the results of trend analyses on 1994-2008 time series data on total waterborne loads of nitrogen and phosphorus are given together with a first evaluation of progress in obtaining the provisional reduction targets by country and by main Baltic Sea sub-region. Chapter 6 includes discussion of some of the main conclusions and advice for future PLCs. The annexes contain the flow-normalized annual load data and figures and tables with results from the PLC-5.

  20. Automatic control model of water filling system with Allen Bradley Micrologix 1400 PLC

    Harahap, R.; Adyatma, AF; Fahmi, F.

    2018-02-01

    Programmable Logic Controller or PLC today plays an important role in most industrial control systems. PLC usage can be encountered in almost all fields of industry, not only in the manufacturing world but also on many other things such as elevators in office buildings, hotels hospitals, and others. PLC is an electronic control tool that operates in logic that its programming can be modified with relative ease. As with any controller in general, the PLC processes input signals to further discharge output according to the desired program. PLC usage is very broad because of its high reliability, can be reprogrammed or modified with relative ease, and very helpful in the tracking troubleshooting. One type of existing PLC is Allen Bradley PLC. Allen Bradley PLC program is commonly used in various industries. PLC Allen Bradley (AB) has several types, and one of them is the type of Micrologic 1400. In this study we design a system as a comparison with the conventional system. For that to explore the use of a PLC program which will be supported by a simulator tool, including a program to RSLogic 500, how to programming, monitoring via RSView32, and modification. It is expected to understand the application aspect of operation and programming of this specific PLC and its potential. The purpose of this research is to design water filling automation system by using Allen Bradley Micrologic 1400 type 1766-L32BXB PLC, empowering the use of Allen Bradley Micrologic 1400 PLC and to regulate the desired process to obtain efficiency and effectiveness compared with conventional system arrangement using Relay.

  1. Webová aplikace v PLC PFC200

    Michalík, David

    2017-01-01

    Tato bakalářská práce se věnuje implementaci vlastního způsobu ovládání vstupů, výstupů a paměti PLC PFC200 od firmy WAGO pomocí dynamického webového rozhraní. Součástí práce je popis PLC, způsobů jeho ovládání, rešerše volně dostupných webových serverů pro Linux a popis metod pro vytvoření real-time ovládání. Výstupem je webová aplikace běžící na webovém serveru v PLC, využívající vlastní runtime systém formou daemon programů. This bachelor’s thesis is mainly focused on implementation of ...

  2. PLC based control system and maintenance activities at NCAR, Bilaspur

    Dewangan, Jaidev; Trivedi, T.; Patel, Shiv P.; Malik, C.; Kumar, Rakesh; Gupta, Santosh Kumar; Bajpai, P.K.

    2015-01-01

    A 3.0 MV high current low energy Pelletron Accelerator facility (Model 9SDH-4, NEC, USA) with TORUIS (ion source for H + and He 2+ beam current H + ion ∼ 50μA @ 6 MeV, He 2+ at ∼ 10μA) and SNICS-II ion source for heavy ions has been commissioned as 'National Centre for Accelerator Based Research' in the Department of Pure and Applied Physics, Guru Ghasidas Vishwavidyalaya. In this paper, we detail out the control system developed and implemented at NCAR. The basic idea of controlling the machine is by providing the output signal through PLC to ACPC of accelerator using user interface points provided by the manufacturer. The PLC based system generates output signal once it receives the feedback signals from search and secure switches, door lock switches and scram switches interlocked with PLC. The output is controlled by ladder logic and is activated only when all the radiation monitors are in healthy state and outside radiations monitor having low radiation level. The details of control system and maintenance activities will be discussed in the paper

  3. Development of an In-line Minority-Carrier Lifetime Monitoring Tool for Process Control during Fabrication of Crystalline Silicon Solar Cells: Final Technical Report, 2 August 2002-15 November 2004

    Sinton, R. A.

    2004-12-01

    The objective of this subcontract over its two-phase, two-year duration was to design and develop improvements to the existing Sinton Consulting R&D minority-carrier lifetime testers. The improvements enable the possibilities for performing various in-line diagnostics on crystalline silicon wafers and cells for solar cell manufacturing lines. This facilitates manufacturing optimization and improved process control. The scope of work for Phase I was to prototype industrial applications for the improved instruments. A small-sample-head version of the instrument was designed and developed in this effort. This new instrument was complemented by detailed application notes detailing the productive use of minority-carrier lifetime measurements for process optimization and routine process control. In Phase II, the results from the first year were applied to design new instruments for industrial applications. These instruments were then characterized and documented. We report here on four new instruments, each optimized for a specific application as demanded by industrial customers. The documentation for these instruments was very technical and involved considerable R&D. Applications were developed that applied the latest in R&D on industrial silicon materials. By investigating the compromises that would be necessary to measure industrial material directly without the sample preparation that is commonly done for good research, we were able to develop several very innovative applications that can now be done directly in the production line for process control.

  4. Fault tree synthesis for software design analysis of PLC based safety-critical systems

    Koo, S. R.; Cho, C. H.; Seong, P. H.

    2006-01-01

    As a software verification and validation should be performed for the development of PLC based safety-critical systems, a software safety analysis is also considered in line with entire software life cycle. In this paper, we propose a technique of software safety analysis in the design phase. Among various software hazard analysis techniques, fault tree analysis is most widely used for the safety analysis of nuclear power plant systems. Fault tree analysis also has the most intuitive notation and makes both qualitative and quantitative analyses possible. To analyze the design phase more effectively, we propose a technique of fault tree synthesis, along with a universal fault tree template for the architecture modules of nuclear software. Consequently, we can analyze the safety of software on the basis of fault tree synthesis. (authors)

  5. Automated chemoenzymatic synthesis of no-carrier-added [carbonyl-11C]propionyl L-carnitine for pharmacokinetic studies

    Davenport, R.J.; Pike, V.W.; Dowsett, K.; Turton, D.R.; Poole, K.

    1997-01-01

    Propionyl-L-carnitine (PLC) is under development as a therapeutic for the treatment of peripheral artery disease, coronary heart disease and chronic heart failure. Three methods were examined for labelling PLC in its propionyl group with positron-emitting carbon-11 (t 1/2 = 20.3 min), one chemical and two chemoenzymatic. The former was based on the preparation of [ 11 C]propionyl chloride as labelling agent via 11 C-carboxylation of ethylmagnesium bromide with cyclotron-produced [ 11 C]carbon dioxide and subsequent chlorination. Reaction of carrier-added [ 11 C]propionyl chloride with L-carnitine in trifluoroacetic acid gave [ 11 C]PLC in 12% radiochemical yield (decay-corrected) from cyclotron-produced [ 11 C]carbon dioxide. However, the radiosynthesis was unsuccessful at the no-carrier added (NCA) level of specific radioactivity. [ 11 C]Propionate, as a radioactive precursor for chemoenzymatic routes, was prepared via carboxylation of ethylmagnesium bromide with [ 11 C]carbon dioxide and hydrolysis. NCA [ 11 C]PLC was prepared in 68 min in 14% radiochemical yield (decay-corrected) from [ 11 C]propionate via sequential conversions catalysed by acetate kinase, phosphotransacetylase and carnitine acetyltransferase. A superior chemoenzymatic synthesis of NCA [ 11 C]PLC was developed, based on the use of a novel supported Grignard reagent for the synthesis of [ 11 C]propionate and conversions by S-acetyl-CoA synthetase and carnitine acetyltransferase. This gave an overall radiochemical yield of 30-48% (decay-corrected). This synthesis was automated for radiation safety and provides pure NCA [ 11 C]PLC in high radioactivities ready for intravenous administration within 25 min from radionuclide production. The [ 11 C]PLC is suitable for pharmacokinetic studies in human subjects with PET and the elucidation of the fate of the propionyl group of PLC in vivo. (Author)

  6. Gene-silencing effects of anti-survivin siRNA delivered by RGDV-functionalized nanodiamond carrier in the breast carcinoma cell line MCF-7

    Bi YZ

    2016-11-01

    Full Text Available Yanzhao Bi, Yifan Zhang, Chunying Cui, Lulu Ren, Xueyun Jiang School of Chemical Biology and Pharmaceutical Sciences, Capital Medical University, Beijing, People’s Republic of China Abstract: Nanodiamond (ND is a renowned material in nonviral small interfering RNA (siRNA carrier field due to its unique physical, chemical, and biological properties. In our previous work, it was proven that ND could deliver siRNA into cells efficiently and downregulate the expression of desired protein. However, synthesizing a high-efficient tumor-targeting carrier using ND is still a challenge. In this study, a novel carrier, NDCONH(CH22NH-VDGR, was synthesized for siRNA delivery, and its properties were characterized with methods including Fourier transform infrared spectrometry, transmission electron microscopy, scanning electron microscopy, gel retardation assay, differential scanning calorimetry, confocal microscopy, releasing test, real-time polymerase chain reaction (PCR assay, enzyme-linked immunosorbent assay (ELISA, flow cytometry, cytotoxicity assay, and gene-silencing efficacy assay in vitro and in vivo. The mechanism of NDCONH(CH22NH-VDGR/survivin-siRNA-induced tumor apoptosis was evaluated via flow cytometer assay using Annexin V–fluorescein isothiocyanate/propidium iodide staining method. The NDCONH(CH22NH-VDGR/survivin-siRNA nanoparticle with 60–110 nm diameter and 35.65±3.90 mV zeta potential was prepared. For real-time PCR assay, the results showed that the expression of survivin mRNA was reduced to 46.77%±6.3%. The expression of survivin protein was downregulated to 48.49%±2.25%, as evaluated by ELISA assay. MTT assay showed that NDCONH(CH22NH-VDGR/survivin-siRNA had an inhibitory effect on MCF-7 cell proliferation. According to these results, the survivin-siRNA could be delivered, transported, and released stably, which benefits in increasing the gene-silencing effect. Therefore, as an siRNA carrier, NDCONH(CH22NH-VDGR was suggested

  7. 49 CFR 1150.22 - Exemptions and common carrier status.

    2010-10-01

    ... the line itself, it will be considered a common carrier. However, when a State acquires a rail line... 49 Transportation 8 2010-10-01 2010-10-01 false Exemptions and common carrier status. 1150.22... common carrier status. The acquisition by a State of a fully abandoned line is not subject to the...

  8. Investigation of Orthogonal Frequency Division Multiplexing Based Power Line Communication Systems

    Hosseinpour, Ali

    2015-01-01

    Power Line Communication (PLC) has the potential to become the preferred technique for providing broadband to homes and offices with the advantage of eliminating the need for new wiring infrastructure and reducing the cost. Power line grids, however, present a hostile channel for data communication, since the fundamental purpose of the power line channel was only the transmission of electric power at 50/60 Hz frequencies. The development of PLC systems for providing broadband applications req...

  9. Non-permeable substrate carrier for electroplating

    Abas, Emmanuel Chua; Chen, Chen-An; Ma, Diana Xiaobing; Ganti, Kalyana Bhargava

    2012-11-27

    One embodiment relates to a substrate carrier for use in electroplating a plurality of substrates. The substrate carrier comprises a non-conductive carrier body on which the substrates are to be held. Electrically-conductive lines are embedded within the carrier body, and a plurality of contact clips are coupled to the electrically-conductive lines embedded within the carrier body. The contact clips hold the substrates in place and electrically couple the substrates to the electrically-conductive lines. The non-conductive carrier body is continuous so as to be impermeable to flow of electroplating solution through the non-conductive carrier body. Other embodiments, aspects and features are also disclosed.

  10. Emulation of Narrowband Powerline Data Transmission Channels and Evaluation of PLC Systems

    Liu, Wenqing

    2013-01-01

    This work proposes advanced emulation of the physical layer behavior of NB-PLC channels and the application of a channel emulator for the evaluation of NB-PLC systems. In addition, test procedures and reference channels are proposed to improve efficiency and accuracy in the system evaluation and classification. This work shows that the channel emulator-based solution opens new ways toward flexible, reliable and technology-independent performance assessment of PLC modems.

  11. Machine interlock and protection system based on PLC for the SSRF linac

    Chou Wenjun; Zhou Dayong; Chen Jianfeng; Shen Liren; Liu Yajuan

    2008-01-01

    This paper describes a machine interlock and protection system used for accelerators based on EPICS (Experimental physics and industrial control system). The system is composed of a front-end computer and an FM-3R logic controller PLC. The alarm signal is passed by the hardware directly, and would be deal with PLC. The reporting, recording and analyst of the event are accomplished by EPICS control software. And PLC is linked to the EPICS by Internet. (authors)

  12. Dual-lifetime referencing (DLR: a powerful method for on-line measurement of internal pH in carrier-bound immobilized biocatalysts

    Boniello Caterina

    2012-03-01

    Full Text Available Abstract Background Industrial-scale biocatalytic synthesis of fine chemicals occurs preferentially as continuous processes employing immobilized enzymes on insoluble porous carriers. Diffusional effects in these systems often create substrate and product concentration gradients between bulk liquid and the carrier. Moreover, some widely-used biotransformation processes induce changes in proton concentration. Unlike the bulk pH, which is usually controlled at a suitable value, the intraparticle pH of immobilized enzymes may deviate significantly from its activity and stability optima. The magnitude of the resulting pH gradient depends on the ratio of characteristic times for enzymatic reaction and on mass transfer (the latter is strongly influenced by geometrical features of the porous carrier. Design and selection of optimally performing enzyme immobilizates would therefore benefit largely from experimental studies of the intraparticle pH environment. Here, a simple and non-invasive method based on dual-lifetime referencing (DLR for pH determination in immobilized enzymes is introduced. The technique is applicable to other systems in which particles are kept in suspension by agitation. Results The DLR method employs fluorescein as pH-sensitive luminophore and Ru(II tris(4,7-diphenyl-1,10-phenantroline, abbreviated Ru(dpp, as the reference luminophore. Luminescence intensities of the two luminophores are converted into an overall phase shift suitable for pH determination in the range 5.0-8.0. Sepabeads EC-EP were labeled by physically incorporating lipophilic variants of the two luminophores into their polymeric matrix. These beads were employed as carriers for immobilization of cephalosporin C amidase (a model enzyme of industrial relevance. The luminophores did not interfere with the enzyme immobilization characteristics. Analytical intraparticle pH determination was optimized for sensitivity, reproducibility and signal stability under

  13. Gene-silencing effects of anti-survivin siRNA delivered by RGDV-functionalized nanodiamond carrier in the breast carcinoma cell line MCF-7.

    Bi, Yanzhao; Zhang, Yifan; Cui, Chunying; Ren, Lulu; Jiang, Xueyun

    Nanodiamond (ND) is a renowned material in nonviral small interfering RNA (siRNA) carrier field due to its unique physical, chemical, and biological properties. In our previous work, it was proven that ND could deliver siRNA into cells efficiently and downregulate the expression of desired protein. However, synthesizing a high-efficient tumor-targeting carrier using ND is still a challenge. In this study, a novel carrier, NDCONH(CH 2 ) 2 NH-VDGR, was synthesized for siRNA delivery, and its properties were characterized with methods including Fourier transform infrared spectrometry, transmission electron microscopy, scanning electron microscopy, gel retardation assay, differential scanning calorimetry, confocal microscopy, releasing test, real-time polymerase chain reaction (PCR) assay, enzyme-linked immunosorbent assay (ELISA), flow cytometry, cytotoxicity assay, and gene-silencing efficacy assay in vitro and in vivo. The mechanism of NDCONH(CH 2 ) 2 NH-VDGR/survivin-siRNA-induced tumor apoptosis was evaluated via flow cytometer assay using Annexin V-fluorescein isothiocyanate/propidium iodide staining method. The NDCONH(CH 2 ) 2 NH-VDGR/survivin-siRNA nanoparticle with 60-110 nm diameter and 35.65±3.90 mV zeta potential was prepared. For real-time PCR assay, the results showed that the expression of survivin mRNA was reduced to 46.77%±6.3%. The expression of survivin protein was downregulated to 48.49%±2.25%, as evaluated by ELISA assay. MTT assay showed that NDCONH(CH 2 ) 2 NH-VDGR/survivin-siRNA had an inhibitory effect on MCF-7 cell proliferation. According to these results, the survivin-siRNA could be delivered, transported, and released stably, which benefits in increasing the gene-silencing effect. Therefore, as an siRNA carrier, NDCONH(CH 2 ) 2 NH-VDGR was suggested to be used in siRNA delivery system and in cancer treatments.

  14. A study of PLC system vulnerability checklists in nuclear power plants

    Cha, Ki Jong; Cho, Gi Ho; Ahn, Jaeh Young; Kim, Young Mi; Kwon, Yong Il

    2012-01-01

    Because the design of the PLCs (Programmable Logic Controller) in the I and C (Instrument and Control) systems for NPP (Nuclear Power Plant) were carried out independently, the problems of cyber security were not addressed in the PLC system designs. Recently, the analysis and the countermeasure development for the PLC systems became mandatory due to the developments in cyber attack techniques and the increasingly revealed vulnerability to such attacks. A comparative analysis on the cyber security checklist of PLC in industry control system and in NPP systems was carried out, and in this paper, the cyber security regulatory trend and the PLC usage status are described

  15. A study of PLC system vulnerability checklists in nuclear power plants

    Cha, Ki Jong; Cho, Gi Ho; Ahn, Jaeh Young [Convergence technology Research Commercialization Center, Daejeon (Korea, Republic of); Kim, Young Mi; Kwon, Yong Il [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2012-10-15

    Because the design of the PLCs (Programmable Logic Controller) in the I and C (Instrument and Control) systems for NPP (Nuclear Power Plant) were carried out independently, the problems of cyber security were not addressed in the PLC system designs. Recently, the analysis and the countermeasure development for the PLC systems became mandatory due to the developments in cyber attack techniques and the increasingly revealed vulnerability to such attacks. A comparative analysis on the cyber security checklist of PLC in industry control system and in NPP systems was carried out, and in this paper, the cyber security regulatory trend and the PLC usage status are described.

  16. Research of home energy management system based on technology of PLC and ZigBee

    Wei, Qi; Shen, Jiaojiao

    2015-12-01

    In view of the problem of saving effectively energy and energy management in home, this paper designs a home energy intelligent control system based on power line carrier communication and wireless ZigBee sensor networks. The system is based on ARM controller, power line carrier communication and wireless ZigBee sensor network as the terminal communication mode, and realizes the centralized and intelligent control of home appliances. Through the combination of these two technologies, the advantages of the two technologies complement each other, and provide a feasible plan for the construction of energy-efficient, intelligent home energy management system.

  17. Application of hepatitis B core particles produced by human primary hepatocellular carcinoma (PLC/342) propagated in nude mice to the determination of anti-HBc by passive hemagglutination.

    Miyamoto, K; Itoh, Y; Tsuda, F; Matsui, T; Tanaka, T; Miyamoto, H; Naitoh, S; Imai, M; Usuda, S; Nakamura, T

    1986-05-22

    Human primary hepatocellular carcinoma (PLC/342), carried by nude mice, produces hepatitis B core particles as well as hepatitis B surface antigen particles. Core particles purified form PLC/342 tumors displayed epitopes of hepatitis B core antigen (HBcAg) but not epitopes of hepatitis B e antigen (HBeAg) on their surface, unlike core particles prepared from Dane particles, derived from plasma of asymptomatic carriers, that expressed epitopes of both HBcAg and HBeAg. Core particles obtained from PLC/342 tumors were applied to the determination of antibody to HBcAg (anti-HBc) by passive hemagglutination. The assay detected anti-HBc not only in individuals with persistent infection with hepatitis B virus and in those who had recovered from transient infection, but also in patients with acute type B hepatitis, indicating that it can detect anti-HBc of either IgG or IgM class. A liberal availability of core particles from tumors carried by nude mice, taken together with an easy applicability of the method, would make the passive hemagglutination for anti-HBc a valuable tool in clinical and epidemiological studies, especially in places where sophisticated methods are not feasible.

  18. Embedded PLC Webserver and Possibilities of its Utilization

    Kopček, Michal

    2016-12-01

    The concept Industry 4.0 is a top theme of recent times. Even if it represents the so-called 4th industrial revolution its main ideas could be used also to support the education of subjects from IT and automation. Furthermore, the basic IT and web technologies inherited by this concept are very well known to students. This paper introduces the embedded webserver of PLC and the options for its optimal utilization. The web server is essentially a simple and widely well-known technology, therefore it was chosen as an example.

  19. AUTOMATION OF GLASS TEMPERING FURNACE BY USING PLC

    Abdullah BÜYÜKYILDIZ

    2007-02-01

    Full Text Available In this study, a furnace which is used for observation of environments under high temperature, and also used for manufacturing of glasses which are resisted to high temperature has been designed and implemented. Automation of this system has been done by using PLC. Operating parameters of furnace such as materials entering, the furnace, the local temperature control of furnace, cooling control and materials outing have been sensed with Hall Effect Sensor. Furthermore, the observation of parameters of furnace on screen has been provided with SCADA software. Obtained products have been shown the system works successfully.

  20. Embedded PLC Webserver and Possibilities of its Utilization

    Kopček Michal

    2016-12-01

    Full Text Available The concept Industry 4.0 is a top theme of recent times. Even if it represents the so-called 4th industrial revolution its main ideas could be used also to support the education of subjects from IT and automation. Furthermore, the basic IT and web technologies inherited by this concept are very well known to students. This paper introduces the embedded webserver of PLC and the options for its optimal utilization. The web server is essentially a simple and widely well-known technology, therefore it was chosen as an example.

  1. Embedded PLC Webserver and Possibilities of its Utilization

    Kopček Michal

    2016-01-01

    The concept Industry 4.0 is a top theme of recent times. Even if it represents the so-called 4th industrial revolution its main ideas could be used also to support the education of subjects from IT and automation. Furthermore, the basic IT and web technologies inherited by this concept are very well known to students. This paper introduces the embedded webserver of PLC and the options for its optimal utilization. The web server is essentially a simple and widely well-known technology, therefo...

  2. A combined PLC and CPU approach to multiprocessor control

    Harris, J.J.; Broesch, J.D.; Coon, R.M.

    1995-10-01

    A sophisticated multiprocessor control system has been developed for use in the E-Power Supply System Integrated Control (EPSSIC) on the DIII-D tokamak. EPSSIC provides control and interlocks for the ohmic heating coil power supply and its associated systems. Of particular interest is the architecture of this system: both a Programmable Logic Controller (PLC) and a Central Processor Unit (CPU) have been combined on a standard VME bus. The PLC and CPU input and output signals are routed through signal conditioning modules, which provide the necessary voltage and ground isolation. Additionally these modules adapt the signal levels to that of the VME I/O boards. One set of I/O signals is shared between the two processors. The resulting multiprocessor system provides a number of advantages: redundant operation for mission critical situations, flexible communications using conventional TCP/IP protocols, the simplicity of ladder logic programming for the majority of the control code, and an easily maintained and expandable non-proprietary system

  3. Commercial information system of Slovak Electricity Transmission System, Plc

    Laznicka, L.

    2004-01-01

    Commercial Information System (CIS), which main role of is to support the commercial activities of the company, is built up by business department of SEPS, Plc in close co-operation with the supplier company Sfera, Plc. The system entries are data from electricity meters obtained by automatized data acquisition and from bugging sheets, contractual hour diagrams, parameters of transmission system like measuring schemes and formulas for calculation of demand and supply, contractual data resulting from agreements, business conditions, URSO decisions and valid legislative. A part of the system is also support of process of data evaluation like calculation of transmitted energy quantity, calculation of actual output diagrams, comparison of actual and contractual diagrams, calculation of system divergence, calculation of demand divergence, etc. The final price for the drawings of services, which are joined with transmission of the electric power will be determined by the accounting process. In this causality there are automatically made out invoices for access, losses, system charges, system services, short-term and long-term transits, divergences and for cross-border transmission auctions. System also generates various specialized synopses and statistics for the evaluation requirements of important aspects and for parameter observations. Successive liberalisation of the electricity power market, changes in legislative and URSO decisions require CIS to be sufficiently configurable and to adapt flexible on the alternating environs. (author)

  4. File list: Pol.Plc.50.RNA_Polymerase_III.AllCell [Chip-atlas[Archive

    Full Text Available Pol.Plc.50.RNA_Polymerase_III.AllCell mm9 RNA polymerase RNA Polymerase III Placent...a http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Pol.Plc.50.RNA_Polymerase_III.AllCell.bed ...

  5. File list: Pol.Plc.50.RNA_polymerase_II.AllCell [Chip-atlas[Archive

    Full Text Available Pol.Plc.50.RNA_polymerase_II.AllCell hg19 RNA polymerase RNA polymerase II Placenta... http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Plc.50.RNA_polymerase_II.AllCell.bed ...

  6. File list: Pol.Plc.20.RNA_polymerase_III.AllCell [Chip-atlas[Archive

    Full Text Available Pol.Plc.20.RNA_polymerase_III.AllCell hg19 RNA polymerase RNA polymerase III Placen...ta http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Plc.20.RNA_polymerase_III.AllCell.bed ...

  7. File list: Pol.Plc.10.RNA_polymerase_II.AllCell [Chip-atlas[Archive

    Full Text Available Pol.Plc.10.RNA_polymerase_II.AllCell hg19 RNA polymerase RNA polymerase II Placenta... http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Plc.10.RNA_polymerase_II.AllCell.bed ...

  8. File list: Pol.Plc.10.RNA_polymerase_III.AllCell [Chip-atlas[Archive

    Full Text Available Pol.Plc.10.RNA_polymerase_III.AllCell hg19 RNA polymerase RNA polymerase III Placen...ta http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Plc.10.RNA_polymerase_III.AllCell.bed ...

  9. File list: Pol.Plc.05.RNA_polymerase_II.AllCell [Chip-atlas[Archive

    Full Text Available Pol.Plc.05.RNA_polymerase_II.AllCell hg19 RNA polymerase RNA polymerase II Placenta... http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Plc.05.RNA_polymerase_II.AllCell.bed ...

  10. 77 FR 32007 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2012-05-31

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... all Rolls-Royce plc (RR) RB211-Trent 800 series turbofan engines. This AD requires removal from...-17, 877- 17, 884-17, 884B-17, 892-17, 892B-17, and 895-17 turbofan engines. (d) Reason This AD was...

  11. 77 FR 73268 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2012-12-10

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... certain Rolls-Royce plc (RR) RB211-Trent 900 series turbofan engines. This AD requires inspection of the... turbofan engines, all serial numbers. (d) Reason This AD was prompted by a Trent 900 engine experiencing a...

  12. 78 FR 17297 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-03-21

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... (AD) for all Rolls-Royce plc (RR) RB211 Trent 500 series turbofan engines. That AD currently requires... 9, 2012), for all RR RB211 Trent 500 series turbofan engines. That AD requires a one-time inspection...

  13. 78 FR 6749 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-01-31

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... (AD) for all Rolls-Royce plc (RR) models RB211 Trent 768-60, 772-60, and 772B-60 turbofan engines... 772B-60 turbofan engines. (d) Reason This AD was prompted by low-pressure (LP) compressor blade partial...

  14. 77 FR 56760 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2012-09-14

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... all Rolls-Royce plc (RR) RB211-Trent 800 series turbofan engines. This AD requires removing from...-17, 892-17, 892B-17, and 895-17 turbofan engines that have an intermediate pressure (IP) turbine disc...

  15. 77 FR 13485 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2012-03-07

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... series turbofan engines. This AD requires inspecting the front combustion liner head section for cracking.... (c) Applicability This AD applies to Rolls-Royce plc (RR) RB211-Trent 800 turbofan engines, all...

  16. Application of PLC technology in measurement of beam profile on 100 MeV accelerator

    Yu Luyang; Chinese Academy of Sciences, Beijing; Chen Yongzhong; Chen Yongzhong; Liu Dekang; Chinese Academy of Sciences, Beijing

    2005-01-01

    A comprehensive introduction is given to the real-time measuring method, which is based on the Programmable Logic Controller (PLC) technology and can measure intensity and profile of the beam by a scintillator screen. The whole system has many advantages, such as good reliability, high precision, intuitional measurement, etc. due to the use of the PLC and Labview software. (authors)

  17. 76 FR 80430 - Rio Tinto plc and Rio Tinto Limited; Notice of Application

    2011-12-23

    ... plc and Rio Tinto Limited; Notice of Application December 19, 2011. AGENCY: Securities and Exchange Commission (``Commission''). ACTION: Notice of application under section 3(b)(2) and 45(a) of the Investment Company Act of 1940 (the ``Act''). SUMMARY: Summary of Application: Rio Tinto plc (``RTP'') and Rio Tinto...

  18. Upgradation in SCADA and PLC of existing LN_2 control system for SST-1

    Panchal, Pradip; Mahesuria, Gaurang; Panchal, Rohit; Patel, Rakesh; Sonara, Dashrath; Pitroda, Dipen; Nimavat, Hiren; Tanna, Vipul; Pradhan, Subrata

    2016-01-01

    Highlights: • The control system of LN_2 Management System of SST-1 is designed on PLC and SCADA. • The implementation and results of up-gradation in PLC and SCADA are reported. • The up-gradation in PLC and SCADA has improved the reliability & availability of SST-1 LN_2 system. - Abstract: Helium Refrigerator/Liquefier system of Steady State Superconducting Tokamak (SST-1) incorporates Liquid Nitrogen (LN_2) pre-cooling system. LN_2 is used for 80 K thermal shields of SST-1, current feeder system and integrated flow distribution and control system. The LN_2 management system is distributed system and requires automatic control. Initially LN_2 control system had Citect based Supervisory Control and Data Acquisition (SCADA) and Koyo make Programmable Logic Controller (PLC). With the passage of time and due to unavailability of their hardware, it is being obsoleted. So, the requirements of new PLC and SCADA systems have been envisaged to make uninterruptable operation of SST-1 cryogenic system. Therefore, Wonderware SCADA and Schneider Electric make PLC is programmed to replace Citect SCADA and Koyo PLC. New control features have been added in upgraded control system for better management of LN_2 system. This upgradation of SCADA and PLC is completed, tested successfully and in operation. Operational performance highlights of the new upgraded system are presented in this paper.

  19. 75 FR 46864 - Airworthiness Directives; Short Brothers PLC Model SD3 Airplanes

    2010-08-04

    ...-0225; Directorate Identifier 2009-NM-203-AD] RIN 2120-AA64 Airworthiness Directives; Short Brothers PLC... this proposed AD, contact Short Brothers PLC, Airworthiness, P.O. Box 241, Airport Road, Belfast, BT3... amend this proposed AD based on those comments. We will post all comments we receive, without change, to...

  20. 75 FR 61114 - Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines

    2010-10-04

    ... Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines AGENCY: Federal Aviation.... Fax: (202) 493-2251. Contact Rolls-Royce plc, P.O. Box 31, Derby, England, DE248BJ; telephone: 011-44... AD. We will consider all comments received by the closing date and may amend this proposed AD based...

  1. 75 FR 264 - Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines

    2010-01-05

    ...-1004; Directorate Identifier 2009-NE-36-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc.... Contact Rolls-Royce plc, P.O. Box 31, Derby, England; telephone: 011-44-1332-249428; fax: 011-44-1332... AD. We will consider all comments received by the closing date and may amend this proposed AD based...

  2. 76 FR 2605 - Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines

    2011-01-14

    ... Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines AGENCY: Federal Aviation... holidays. Fax: (202) 493-2251. Contact Rolls-Royce plc, P.O. Box 31, DERBY, DE24 8BJ, UK; telephone 44 (0... AD. We will consider all comments received by the closing date and may amend this proposed AD based...

  3. 76 FR 24796 - Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines

    2011-05-03

    ... Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines AGENCY: Federal Aviation.... Request To Revise the Compliance Times Four commenters, American Airlines, Delta Airlines, Rolls-Royce plc... SNPRM were developed to minimize the risk of uncontained disc failure, based on the age of the parts in...

  4. 78 FR 54149 - Airworthiness Directives; Rolls-Royce plc (RR) Turbofan Engines

    2013-09-03

    ... Airworthiness Directives; Rolls-Royce plc (RR) Turbofan Engines AGENCY: Federal Aviation Administration (FAA... service information identified in this AD, contact Rolls-Royce plc, Corporate Communications, P.O. Box 31... per hour. Replacement parts are estimated to cost about $2,271 per engine. Based on these figures, we...

  5. 76 FR 65136 - Airworthiness Directives; Rolls-Royce plc (RR) Turbofan Engines

    2011-10-20

    ... Airworthiness Directives; Rolls-Royce plc (RR) Turbofan Engines AGENCY: Federal Aviation Administration (FAA... information identified in this AD, contact Rolls-Royce plc, Corporate Communications, P.O. Box 31, Derby... 8, 2011, to perform the inspection. Costs of Compliance Based on the service information, we...

  6. 76 FR 52288 - Airworthiness Directives; Rolls-Royce plc (RR) Trent 800 Series Turbofan Engines

    2011-08-22

    ...-0836; Directorate Identifier 2010-NE-38-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR... plc, P.O. Box 31, Derby, DE24 8BJ, United Kingdom: telephone 44 (0) 1332 242424; fax 44 (0) 1332... based on those comments. We will post all comments we receive, without change, to http://www.regulations...

  7. Translation of PLC Programs to x86 for Simulation and Verification

    Sallai, Gyula

    2017-01-01

    PLC programs are written in special languages, variants of the languages defined in the IEC 61131 standard. These programs cannot be directly executed on personal computers (on x86 architecture). To perform simulation of the PLC program or diagnostics during development, either a real PLC or a PLC simulator has to be used. However, these solutions are often inflexible and they do not provide appropriate performance. By generating x86-representations (semantically equivalent programs which can be executed on PCs, e.g. written in C, C++ or Java) of the PLC programs, some of these challenges could be met. PLCverif is a PLC program verification tool developed at CERN which includes a parser for Siemens PLC programs. In this work, we describe a code generator based on this parser of PLCverif. This work explores the possibilities and challenges of generating programs in widely-used general purpose languages from PLC programs, and provides a proof-of-concept code generation implementation. The presented solution dem...

  8. Upgradation in SCADA and PLC of existing LN{sub 2} control system for SST-1

    Panchal, Pradip, E-mail: pradip@ipr.res.in; Mahesuria, Gaurang; Panchal, Rohit; Patel, Rakesh; Sonara, Dashrath; Pitroda, Dipen; Nimavat, Hiren; Tanna, Vipul; Pradhan, Subrata

    2016-11-15

    Highlights: • The control system of LN{sub 2} Management System of SST-1 is designed on PLC and SCADA. • The implementation and results of up-gradation in PLC and SCADA are reported. • The up-gradation in PLC and SCADA has improved the reliability & availability of SST-1 LN{sub 2} system. - Abstract: Helium Refrigerator/Liquefier system of Steady State Superconducting Tokamak (SST-1) incorporates Liquid Nitrogen (LN{sub 2}) pre-cooling system. LN{sub 2} is used for 80 K thermal shields of SST-1, current feeder system and integrated flow distribution and control system. The LN{sub 2} management system is distributed system and requires automatic control. Initially LN{sub 2} control system had Citect based Supervisory Control and Data Acquisition (SCADA) and Koyo make Programmable Logic Controller (PLC). With the passage of time and due to unavailability of their hardware, it is being obsoleted. So, the requirements of new PLC and SCADA systems have been envisaged to make uninterruptable operation of SST-1 cryogenic system. Therefore, Wonderware SCADA and Schneider Electric make PLC is programmed to replace Citect SCADA and Koyo PLC. New control features have been added in upgraded control system for better management of LN{sub 2} system. This upgradation of SCADA and PLC is completed, tested successfully and in operation. Operational performance highlights of the new upgraded system are presented in this paper.

  9. File list: Pol.Plc.05.RNA_polymerase_III.AllCell [Chip-atlas[Archive

    Full Text Available Pol.Plc.05.RNA_polymerase_III.AllCell hg19 RNA polymerase RNA polymerase III Placen...ta http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Plc.05.RNA_polymerase_III.AllCell.bed ...

  10. File list: Pol.Plc.20.RNA_polymerase_II.AllCell [Chip-atlas[Archive

    Full Text Available Pol.Plc.20.RNA_polymerase_II.AllCell hg19 RNA polymerase RNA polymerase II Placenta... http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Plc.20.RNA_polymerase_II.AllCell.bed ...

  11. File list: Pol.Plc.50.RNA_polymerase_III.AllCell [Chip-atlas[Archive

    Full Text Available Pol.Plc.50.RNA_polymerase_III.AllCell hg19 RNA polymerase RNA polymerase III Placen...ta http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Plc.50.RNA_polymerase_III.AllCell.bed ...

  12. File list: InP.Plc.50.Input_control.AllCell [Chip-atlas[Archive

    Full Text Available InP.Plc.50.Input_control.AllCell hg19 Input control Input control Placenta SRX19004...9,SRX080366 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/InP.Plc.50.Input_control.AllCell.bed ...

  13. File list: InP.Plc.20.Input_control.AllCell [Chip-atlas[Archive

    Full Text Available InP.Plc.20.Input_control.AllCell mm9 Input control Input control Placenta SRX112971...02,SRX404310,SRX1072160,SRX871507,SRX192097,SRX192098,SRX192099,SRX204148 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/InP.Plc.20.Input_control.AllCell.bed ...

  14. File list: InP.Plc.05.Input_control.AllCell [Chip-atlas[Archive

    Full Text Available InP.Plc.05.Input_control.AllCell hg19 Input control Input control Placenta SRX19004...9,SRX080366 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/InP.Plc.05.Input_control.AllCell.bed ...

  15. File list: InP.Plc.05.Input_control.AllCell [Chip-atlas[Archive

    Full Text Available InP.Plc.05.Input_control.AllCell mm9 Input control Input control Placenta SRX344647...160,SRX204147,SRX404310,SRX871506,SRX871507,SRX192098,SRX192097,SRX192099 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/InP.Plc.05.Input_control.AllCell.bed ...

  16. File list: InP.Plc.10.Input_control.AllCell [Chip-atlas[Archive

    Full Text Available InP.Plc.10.Input_control.AllCell mm9 Input control Input control Placenta SRX344648...310,SRX871506,SRX142911,SRX871507,SRX204148,SRX192098,SRX192097,SRX192099 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/InP.Plc.10.Input_control.AllCell.bed ...

  17. Fc gamma receptor activation induces the tyrosine phosphorylation of both phospholipase C (PLC)-gamma 1 and PLC-gamma 2 in natural killer cells

    1992-01-01

    Crosslinking of the low affinity immunoglobulin G (IgG) Fc receptor (Fc gamma R type III) on natural killer (NK) cells initiates antibody- dependent cellular cytotoxicity. During this process, Fc gamma R stimulation results in the rapid activation of phospholipase C (PLC), which hydrolyzes membrane phosphoinositides, generating inositol-1,4,5- trisphosphate and sn-1,2-diacylglycerol as second messengers. We have recently reported that PLC activation after Fc gamma R stimulation can be inhibit...

  18. The Integration of DCS I/O to an Existing PLC

    Sadhukhan, Debashis; Mihevic, John

    2013-01-01

    At the NASA Glenn Research Center (GRC), Existing Programmable Logic Controller (PLC) I/O was replaced with Distributed Control System (DCS) I/O, while keeping the existing PLC sequence Logic. The reason for integration of the PLC logic and DCS I/O, along with the evaluation of the resulting system is the subject of this paper. The pros and cons of the old system and new upgrade are described, including operator workstation screen update times. Detail of the physical layout and the communication between the PLC, the DCS I/O and the operator workstations are illustrated. The complex characteristics of a central process control system and the plan to remove the PLC processors in future upgrades is also discussed.

  19. Silica-based PLC with heterogeneously-integrated PDs for one-chip DP-QPSK receiver.

    Kurata, Yu; Nasu, Yusuke; Tamura, Munehisa; Kasahara, Ryoichi; Aozasa, Shinichi; Mizuno, Takayuki; Yokoyama, Haruki; Tsunashima, Satoshi; Muramoto, Yoshifumi

    2012-12-10

    To realize a DP-QPSK receiver PLC, we heterogeneously integrated eight high-speed PDs on a silica-based PLC platform with a PBS, 90-degree optical hybrids and a VOA. The use of a 2.5%-Δ waveguide reduced the receiver PLC size to 11 mm x 11 mm. We successfully demonstrated 32 Gbaud DP-QPSK signal demodulation with the receiver PLC.

  20. Anti-hepatocarcinoma effects of berberine-nanostructured lipid carriers against human HepG2, Huh7, and EC9706 cancer cell lines

    Meng, Xiang-Ping; Fan, Hua; Wang, Yi-fei; Wang, Zhi-ping; Chen, Tong-sheng

    2016-10-01

    Hepatocarcinoma and esophageal squamous cell carcinomas threaten human life badly. It is a current issue to seek the effective natural remedy from plant to treat cancer due to the resistance of the advanced hepatocarcinoma and esophageal carcinoma to chemotherapy. Berberine (Ber), an isoquinoline derivative alkaloid, has a wide range of pharmacological properties and is considered to have anti-hepatocarcinoma and antiesophageal carcinoma effects. However its low oral bioavailability restricts its wide application. In this report, Ber loaded nanostructured lipid carriers (Ber-NLC) was prepared by hot melting and then high pressure homogenization technique. The in vitro anti-hepatocarcinoma and antiesophageal carcinoma effects of Ber-NLC relative to efficacy of bulk Ber were evaluated. The particle size and zeta potential of Ber-NLC were 189.3 +/- 3.7 nm and -19.3 +/- 1.4 mV, respectively. MTT assay showed that Ber-NLC effectively inhibited the proliferation of human HepG2 and Huh7 and EC9706 cells, and the corresponding IC50 value was 9.1 μg/ml, 4.4 μg/ml, and 6.3 μg/ml (18.3μg/ml, 6.5μg/ml, and 12.4μg/ml μg/ml of bulk Ber solution), respectively. These results suggest that the delivery of Ber-NLC is a promising approach for treating tumors.

  1. A new cell line-based coculture model of the human air-blood barrier to evaluate the interaction with aerosolized drug carriers

    Kletting, Stephanie

    2016-01-01

    Besides reducing animal testing, in vitro models allow for the pre-screening of new drug candidates in terms of safety and efficacy before they enter clinical trials. To date, models mimicking the deep lung show limitations such as cellular origin or lack of appropriate barrier properties. Therefore, the focus of this work was on the establishment of a robust and reproducible cell line-based coculture model that reflects the two major barrier structures present in the alveolar region, namely ...

  2. A Novel Method to Improve the Anticancer Activity of Natural-Based Hydroxyapatite against the Liver Cancer Cell Line HepG2 Using Mesoporous Magnesia as a Micro-Carrier

    Nasser S. Awwad

    2017-11-01

    Full Text Available Micro-carriers are the best known vehicles to transport different kinds of drugs to achieve high impact. In this study, mesoporous magnesium oxide has been harnessed as a micro-carrier to encapsulate the anticancer candidate drug natural-based cubic hydroxyapatite (HAP. HAP@MgO composites with different HAP loading (0–60 wt %, were prepared by a hydrothermal treatment method using triethanol amine as a template. The characterization of the prepared composites were achieved by using XRD, Raman spectroscopy, FTIR and SEM. Characterization data confirm the formation of sphere-like structures of MgO containing HAP particles. It was observed that the size of the spheres increased with HAP loading up to 40 wt %, then collapsed. Furthermore, the anticancer property of the prepared composites was evaluated against the HepG2 liver cancer cell line. The HAP@MgO composites exhibited higher activity than neat MgO or HAP. The 20 wt % of HAP was the optimum loading to control cell proliferation by inducing apoptosis. Apoptosis was determined by typical apoptotic bodies produced by the cell membrane.

  3. A Novel Method to Improve the Anticancer Activity of Natural-Based Hydroxyapatite against the Liver Cancer Cell Line HepG2 Using Mesoporous Magnesia as a Micro-Carrier.

    2017-11-24

    Micro-carriers are the best known vehicles to transport different kinds of drugs to achieve high impact. In this study, mesoporous magnesium oxide has been harnessed as a micro-carrier to encapsulate the anticancer candidate drug natural-based cubic hydroxyapatite (HAP). HAP@MgO composites with different HAP loading (0-60 wt %), were prepared by a hydrothermal treatment method using triethanol amine as a template. The characterization of the prepared composites were achieved by using XRD, Raman spectroscopy, FTIR and SEM. Characterization data confirm the formation of sphere-like structures of MgO containing HAP particles. It was observed that the size of the spheres increased with HAP loading up to 40 wt %, then collapsed. Furthermore, the anticancer property of the prepared composites was evaluated against the HepG2 liver cancer cell line. The HAP@MgO composites exhibited higher activity than neat MgO or HAP. The 20 wt % of HAP was the optimum loading to control cell proliferation by inducing apoptosis. Apoptosis was determined by typical apoptotic bodies produced by the cell membrane.

  4. Knowledge-based engineering of a PLC controlled telescope

    Pessemier, Wim; Raskin, Gert; Saey, Philippe; Van Winckel, Hans; Deconinck, Geert

    2016-08-01

    As the new control system of the Mercator Telescope is being finalized, we can review some technologies and design methodologies that are advantageous, despite their relative uncommonness in astronomical instrumentation. Particular for the Mercator Telescope is that it is controlled by a single high-end soft-PLC (Programmable Logic Controller). Using off-the-shelf components only, our distributed embedded system controls all subsystems of the telescope such as the pneumatic primary mirror support, the hydrostatic bearing, the telescope axes, the dome, the safety system, and so on. We show how real-time application logic can be written conveniently in typical PLC languages (IEC 61131-3) and in C++ (to implement the pointing kernel) using the commercial TwinCAT 3 programming environment. This software processes the inputs and outputs of the distributed system in real-time via an observatory-wide EtherCAT network, which is synchronized with high precision to an IEEE 1588 (PTP, Precision Time Protocol) time reference clock. Taking full advantage of the ability of soft-PLCs to run both real-time and non real-time software, the same device also hosts the most important user interfaces (HMIs or Human Machine Interfaces) and communication servers (OPC UA for process data, FTP for XML configuration data, and VNC for remote control). To manage the complexity of the system and to streamline the development process, we show how most of the software, electronics and systems engineering aspects of the control system have been modeled as a set of scripts written in a Domain Specific Language (DSL). When executed, these scripts populate a Knowledge Base (KB) which can be queried to retrieve specific information. By feeding the results of those queries to a template system, we were able to generate very detailed "browsable" web-based documentation about the system, but also PLC software code, Python client code, model verification reports, etc. The aim of this paper is to

  5. Automated chemoenzymatic synthesis of no-carrier-added [carbonyl-{sup 11}C]propionyl L-carnitine for pharmacokinetic studies

    Davenport, R.J.; Pike, V.W.; Dowsett, K.; Turton, D.R.; Poole, K. [Hammersmith Hospital, London (United Kingdom). MRC Cyclotron Unit

    1997-07-30

    Propionyl-L-carnitine (PLC) is under development as a therapeutic for the treatment of peripheral artery disease, coronary heart disease and chronic heart failure. Three methods were examined for labelling PLC in its propionyl group with positron-emitting carbon-11 (t{sub 1/2} = 20.3 min), one chemical and two chemoenzymatic. The former was based on the preparation of [{sup 11}C]propionyl chloride as labelling agent via {sup 11}C-carboxylation of ethylmagnesium bromide with cyclotron-produced [{sup 11}C]carbon dioxide and subsequent chlorination. Reaction of carrier-added [{sup 11}C]propionyl chloride with L-carnitine in trifluoroacetic acid gave [{sup 11}C]PLC in 12% radiochemical yield (decay-corrected) from cyclotron-produced [{sup 11}C]carbon dioxide. However, the radiosynthesis was unsuccessful at the no-carrier added (NCA) level of specific radioactivity. [{sup 11}C]Propionate, as a radioactive precursor for chemoenzymatic routes, was prepared via carboxylation of ethylmagnesium bromide with [{sup 11}C]carbon dioxide and hydrolysis. NCA [{sup 11}C]PLC was prepared in 68 min in 14% radiochemical yield (decay-corrected) from [{sup 11}C]propionate via sequential conversions catalysed by acetate kinase, phosphotransacetylase and carnitine acetyltransferase. A superior chemoenzymatic synthesis of NCA [{sup 11}C]PLC was developed, based on the use of a novel supported Grignard reagent for the synthesis of [{sup 11}C]propionate and conversions by S-acetyl-CoA synthetase and carnitine acetyltransferase. This gave an overall radiochemical yield of 30-48% (decay-corrected). This synthesis was automated for radiation safety and provides pure NCA [{sup 11}C]PLC in high radioactivities ready for intravenous administration within 25 min from radionuclide production. The [{sup 11}C]PLC is suitable for pharmacokinetic studies in human subjects with PET and the elucidation of the fate of the propionyl group of PLC in vivo. (Author).

  6. British Nuclear Fuels PLC: report and accounts 1989-90

    1991-01-01

    Members of the Energy Select Committee put questions to representatives of British Nuclear Fuels PLC (BNFL) about the annual report and accounts 1989-90. Questions concerned the late publication of the accounts, BNFLs role in the downfall of the nuclear privatisation, government assistance to the nuclear industry, the price BNFL charges for fuel reprocessing and the process of laser isotope separation of uranium. The committee also asked about the rate of return in BNFL's assets as a percentage, Sellafield's potential as a site for a deep repository for radioactive wastes and the 6000 boreholes that MREX will drill at Sellafield. The commercial case for reprocessing is made. Feasibility studies for possible new reactions at Sellafield and Chapel Cross have been carried out. On the whole the Energy Committee were satisfied with the replies from BNFL. (UK)

  7. Formal verification of complex properties on PLC programs

    Darvas, D; Voros, A; Bartha, T; Blanco Vinuela, E; Gonzalez Suarez, V M

    2014-01-01

    Formal verification has become a recommended practice in the safety-critical application areas. However, due to the complexity of practical control and safety systems, the state space explosion often prevents the use of formal analysis. In this paper we extend our former verification methodology with effective property preserving reduction techniques. For this purpose we developed general rule-based reductions and a customized version of the Cone of Influence (COI) reduction. Using these methods, the verification of complex requirements formalised with temporal logics (e.g. CTL, LTL) can be orders of magnitude faster. We use the NuSMV model checker on a real-life PLC program from CERN to demonstrate the performance of our reduction techniques.

  8. Development of multifunctional radiation monitoring instrument based on PLC technology

    Li Ziqiang; Zhu Yuye; Zhuang Min

    2007-01-01

    This eight-channel multifunctional Radiation Monitoring Instrument is developed by making use of the built-in high-speed counters and the powerful instruction system of the SIEMES SIMATICS S7 series Programmable Logic Controllers (PLC) to record and process the pulse signal output by the detectors. The instrument with functions, such as analog and digital display, digital storage of digital data, pulse signal generator, network communication, can connect various types of pulse detectors. The initial process can be translated between Graduation Apparatus method and Formula method. the logicality of the high-dosage warning system is processed itself. The signal output will drive the alarm lights and bell directly. This paper mainly describes the configuration, programming and feature of the instrument. (authors)

  9. Normal and pathological NMR imaging aspects of the posterolateral corner (PLC) of the knee

    Tardieu, M.; Lazennec, J.Y.; Christel, P.; Brasseur, J.L.; Roger, B.; Grenier, P.

    1995-01-01

    The purpose of the study is to compare normal PLC (limits lateral condyle anterior sub luxation) anatomy and its magnetic resonance imaging (MRI) appearance, with the various lesions observed in MRI, from the simple popliteus tendinous contusion to the complete PLC rupture. For this specific work on PLC lesions, we selected 61 examinations among the traumatic knees explored during the last 3 years. Surgical correlation is obtained for the 61 patients. MRI examinations are performed on a 0.5 T. unit. Normal PLC anatomy is compared to the dissection of 4 anatomic subjects. Normal MRI slices are evaluated with this reference analysis. The principle anatomical structures of the PLC include the lateral collateral ligament, the popliteus tendon, the arcuate ligament, the fabello fibular ligament, the posterolateral condylar capsule, and the posterior horn of the lateral meniscus. Surgical findings confirm PLC lesion for 58 patients with 3 false positive. Diagnosis of these lesions is important because chronical posterolateral laxity is secondary to the destabilization of lateral condyle. Unrecognized and untreated posterolateral instability may result in failure of ACL (limits lateral condyle posterior sub-luxation) reconstruction. When clinical tests are doubtful or complex, or the examination very painful, MRI evaluates completely the traumatic knee and particularly the PLC. (authors). 3 refs., 26 figs

  10. Application of PLC timing control in the neutral beam injector of HT-7

    Song Shihua; Liu Zhimin; Liu Sheng; Hu Chundong

    2006-01-01

    HT-7 tokamak high power Neutral Beam Injector heating system runs in the mode of pulse timing-control of PLC. The thesis discusses the theory about the operation for the experiment of discharge, which is controlled by PLC logical connection and introduces excellent user-friendly operating interface and the development of the ladder application program and upper monitor program in the VB6.0 environment. Monitor the conditions of power and facility real time by the upper monitor interface. The application of PLC control system ensures the experiment facility running safely and convenient for modifying and setting the parameter simply during the course of experiment. (authors)

  11. Strategies for Power Line Communications Smart Metering Network Deployment

    Alberto Sendin

    2014-04-01

    Full Text Available Smart Grids are becoming a reality all over the world. Nowadays, the research efforts for the introduction and deployment of these grids are mainly focused on the development of the field of Smart Metering. This emerging application requires the use of technologies to access the significant number of points of supply (PoS existing in the grid, covering the Low Voltage (LV segment with the lowest possible costs. Power Line Communications (PLC have been extensively used in electricity grids for a variety of purposes and, of late, have been the focus of renewed interest. PLC are really well suited for quick and inexpensive pervasive deployments. However, no LV grid is the same in any electricity company (utility, and the particularities of each grid evolution, architecture, circumstances and materials, makes it a challenge to deploy Smart Metering networks with PLC technologies, with the Smart Grid as an ultimate goal. This paper covers the evolution of Smart Metering networks, together with the evolution of PLC technologies until both worlds have converged to project PLC-enabled Smart Metering networks towards Smart Grid. This paper develops guidelines over a set of strategic aspects of PLC Smart Metering network deployment based on the knowledge gathered on real field; and introduces the future challenges of these networks in their evolution towards the Smart Grid.

  12. A Study on the Optimal Receiver Impedance for SNR Maximization in Broadband PLC

    Massimo Antoniali

    2013-01-01

    Full Text Available We consider the design of the front-end receiver for broadband power line communications. We focus on the design of the input impedance that maximizes the signal-to-noise ratio (SNR at the receiver. We show that the amplitude, rather than the power, of the received signal is important for communication purposes. Furthermore, we show that the receiver impedance impacts the amplitude of the noise term. We focus on the background noise, and we propose a novel description of the noise experienced at the receiver port of a PLC network. We model the noise as the sum of four uncorrelated contributions, that is, the active, resistive, receiver, and coupled noise components. We study the optimal impedance design problem for real in-home grids that we assessed with experimental measurements. We describe the results of the measurement campaign, and we report the statistics of the optimal impedance. Hence, we study the best attainable performance when the optimal receiver impedance is deployed. We focus on the SNR and the maximum achievable rate, and we show that power matching is suboptimal with respect to the proposed impedance design approach.

  13. PLAT: An Automated Fault and Behavioural Anomaly Detection Tool for PLC Controlled Manufacturing Systems

    Arup Ghosh

    2016-01-01

    Full Text Available Operational faults and behavioural anomalies associated with PLC control processes take place often in a manufacturing system. Real time identification of these operational faults and behavioural anomalies is necessary in the manufacturing industry. In this paper, we present an automated tool, called PLC Log-Data Analysis Tool (PLAT that can detect them by using log-data records of the PLC signals. PLAT automatically creates a nominal model of the PLC control process and employs a novel hash table based indexing and searching scheme to satisfy those purposes. Our experiments show that PLAT is significantly fast, provides real time identification of operational faults and behavioural anomalies, and can execute within a small memory footprint. In addition, PLAT can easily handle a large manufacturing system with a reasonable computing configuration and can be installed in parallel to the data logging system to identify operational faults and behavioural anomalies effectively.

  14. 78 FR 6206 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-01-30

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT..., RB211-Trent 977-84, RB211-Trent 977B-84 and RB211-Trent 980-84 turbofan engines. This AD requires on...

  15. 77 FR 20987 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2012-04-09

    ... Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION... the Federal Register. That AD applies to RB211-Trent 800 series turbofan engines. The last comment...

  16. The application of PLC automatic control system for resin transfer in pulsed elution

    Long Maoxiong

    2001-01-01

    An application of Programmable Logic Controller (PLC) in automatic control system for resin transfer in pulsed elution column is described. The design principle as well as hardware and software are also described in detail

  17. Modelling and Formal Verification of Timing Aspects in Large PLC Programs

    Fernandez Adiego, B; Blanco Vinuela, E; Tournier, J-C; Gonzalez Suarez, V M; Blech, J O

    2014-01-01

    One of the main obstacle that prevents model checking from being widely used in industrial control systems is the complexity of building formal models out of PLC programs, especially when timing aspects need to be integrated. This paper brings an answer to this obstacle by proposing a methodology to model and verify timing aspects of PLC programs. Two approaches are proposed to allow the users to balance the trade-off between the complexity of the model, i.e. its number of states, and the set of specifications possible to be verified. A tool supporting the methodology which allows to produce models for different model checkers directly from PLC programs has been developed. Verification of timing aspects for real-life PLC programs are presented in this paper using NuSMV.

  18. A formal safety analysis for PLC software-based safety critical system using Z

    Koh, Jung Soo; Seong, Poong Hyun

    1997-01-01

    This paper describes a formal safety analysis technique which is demonstrated by performing empirical formal safety analysis with the case study of beamline hutch door Interlock system that is developed by using PLC (Programmable Logic Controller) systems at the Pohang Accelerator Laboratory. In order to perform formed safety analysis, we have built the Z formal specifications representation from user requirement written in ambiguous natural language and target PLC ladder logic, respectively. We have also studied the effective method to express typical PLC timer component by using specific Z formal notation which is supported by temporal history. We present a formal proof technique specifying and verifying that the hazardous states are not introduced into ladder logic in the PLC-based safety critical system

  19. PLAT: An Automated Fault and Behavioural Anomaly Detection Tool for PLC Controlled Manufacturing Systems.

    Ghosh, Arup; Qin, Shiming; Lee, Jooyeoun; Wang, Gi-Nam

    2016-01-01

    Operational faults and behavioural anomalies associated with PLC control processes take place often in a manufacturing system. Real time identification of these operational faults and behavioural anomalies is necessary in the manufacturing industry. In this paper, we present an automated tool, called PLC Log-Data Analysis Tool (PLAT) that can detect them by using log-data records of the PLC signals. PLAT automatically creates a nominal model of the PLC control process and employs a novel hash table based indexing and searching scheme to satisfy those purposes. Our experiments show that PLAT is significantly fast, provides real time identification of operational faults and behavioural anomalies, and can execute within a small memory footprint. In addition, PLAT can easily handle a large manufacturing system with a reasonable computing configuration and can be installed in parallel to the data logging system to identify operational faults and behavioural anomalies effectively.

  20. Electromagnetic compatibility of PLC adapters for in-home/domestic networks

    Potisk, Lukas; Hallon, Jozef; Orgon, Milos; Fujdiak, Radek

    2018-01-01

    The use of programable logic controllers (PLC) technology in electrical networks 230 V causes electromagnetic radiation that interferes with other electrical equipment connected to the network [1-4]. Therefore, this article describes the issues of electromagnetic compatibility (EMC) of new PLC adapters used in IP broadband services in a multi-user environment. The measurements of disturbing electromagnetic field originated in PLC adapters were made in a certified laboratory EMC (laboratory of electromagnetic compatibility) in the Institute of Electrical Engineering at Faculty of Electrical Engineering and Information Technology of the Slovak University of Technology in Bratislava. The measured spectra of the radiated electromagnetic field will be compared with the results obtained when testing older PLC modems [5].

  1. Developing a PLC-friendly state machine model: lessons learned

    Pessemier, Wim; Deconinck, Geert; Raskin, Gert; Saey, Philippe; Van Winckel, Hans

    2014-07-01

    Modern Programmable Logic Controllers (PLCs) have become an attractive platform for controlling real-time aspects of astronomical telescopes and instruments due to their increased versatility, performance and standardization. Likewise, vendor-neutral middleware technologies such as OPC Unified Architecture (OPC UA) have recently demonstrated that they can greatly facilitate the integration of these industrial platforms into the overall control system. Many practical questions arise, however, when building multi-tiered control systems that consist of PLCs for low level control, and conventional software and platforms for higher level control. How should the PLC software be structured, so that it can rely on well-known programming paradigms on the one hand, and be mapped to a well-organized OPC UA interface on the other hand? Which programming languages of the IEC 61131-3 standard closely match the problem domains of the abstraction levels within this structure? How can the recent additions to the standard (such as the support for namespaces and object-oriented extensions) facilitate a model based development approach? To what degree can our applications already take advantage of the more advanced parts of the OPC UA standard, such as the high expressiveness of the semantic modeling language that it defines, or the support for events, aggregation of data, automatic discovery, ... ? What are the timing and concurrency problems to be expected for the higher level tiers of the control system due to the cyclic execution of control and communication tasks by the PLCs? We try to answer these questions by demonstrating a semantic state machine model that can readily be implemented using IEC 61131 and OPC UA. One that does not aim to capture all possible states of a system, but rather one that attempts to organize the course-grained structure and behaviour of a system. In this paper we focus on the intricacies of this seemingly simple task, and on the lessons that we

  2. Design of EAST LHCD high power supply feedback control system based on PLC

    Hu Huaichuan; Shan Jiafang

    2009-01-01

    Design of EAST LHCD -35kV/5.6MW high power supply feedback control system based on PLC is described. Industrial computer and PLC are used to control high power supply in the system. PID arithmetic is adopted to achieve the feedback control of voltage of high power supply. Operating system is base on real-time operating system of QNX. Good controlling properties and reliable protective properties of the feedback control system are proved by the experiment results. (authors)

  3. 77 FR 75831 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2012-12-26

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... certain serial numbers (S/Ns) of Rolls-Royce plc (RR) RB211-Trent 768-60, 772- 60, and 772B-60 turbofan... use any of the RB211-Trent 768-60, 772-60, and 772B-60 turbofan engines listed by S/N in this AD...

  4. Operating experiences with programmable logic controller (PLC) system of Indian Pressurised Heavy Water Reactors (PHWR)

    Ughade, A.V.; Singh, Ranjeet; Bhattacharya, P.K.; Kulkarni, R.K.; Chandra, Umesh

    2005-01-01

    PLC system was introduced for the first time in Kaiga-1,2 and RAPS-3,4 Nuclear Power Plants (NPPs) for Station Logic Control of Non Safety Related (NSR) and Safety related (SR) systems. However, the safety system logics are still relay based. The experience on the deployment of PLC system, which is computer-based, has brought out various implementation issues. This paper give details of such experiences, the solutions emerged and applied for plants under operation/construction. (author)

  5. Bit rate maximization for multicast LP-OFDM systems in PLC context

    Maiga , Ali; Baudais , Jean-Yves; Hélard , Jean-François

    2009-01-01

    ISBN: 978-88-900984-8-2.; International audience; In this paper, we propose a new resource allocation algorithm based on linear precoding technique for multicast OFDM systems. Linear precoding technique applied to OFDM systems has already proved its ability to significantly increase the system throughput in a powerline communication (PLC) context. Simulations through PLC channels show that this algorithm outperforms the classical multicast method (up to 7.3% bit rate gain) and gives better pe...

  6. The YvfTU Two-component System is involved in plcR expression in Bacillus cereus

    Nguyen-the Christophe

    2008-10-01

    Full Text Available Abstract Background Most extracellular virulence factors produced by Bacillus cereus are regulated by the pleiotropic transcriptional activator PlcR. Among strains belonging to the B. cereus group, the plcR gene is always located in the vicinity of genes encoding the YvfTU two-component system. The putative role of YvfTU in the expression of the PlcR regulon was therefore investigated. Results Expression of the plcR gene was monitored using a transcriptional fusion with a lacZ reporter gene in a yvfTU mutant and in its B. cereus ATCC 14579 parental strain. Two hours after the onset of the stationary phase, a stage at which the PlcR regulon is highly expressed, the plcR expression in the yvfTU mutant was only 50% of that of its parental strain. In addition to the reduced plcR expression in the yvfTU mutant, a few members of the PlcR regulon showed a differential expression, as revealed by transcriptomic and proteomic analyses. The virulence of the yvfTU mutant in a Galleria mellonella insect model was slightly lower than that of the parental strain. Conclusion The YvfTU two-component system is not required for the expression of most of the virulence factors belonging to the PlcR regulon. However, YvfTU is involved in expression of plcR, a major regulator of virulence in B. cereus.

  7. Development of Multipurpose PLC trainer for the simulator of reactor safety system

    Syaiful Bakhri; Deswandri; Ahmad Abtokhi

    2014-01-01

    PLC becomes one of the essential components for the current type of reactor which based on digital instrumentation and control. Several studies have demonstrated the promising results including the implementation of PLC's for RSG-GAS research reactor. However, research for the safety and reliability analysis can not be carried out freely in the existing systems.Therefore, this research aims to develop a PLC trainer employing micro PLC OMRON CP1MA which can be useful for simulator of various topics in reactor safety. Two experimental tests were carried out to show the PLC’s performances. The first experimental testing implementing reactor protection system of research reactor RSG-GAS shows the capacity of PLC system to identify the initiator of the SCRAM logic as well as giving a promptly response. Secondly, the application of PLC to controls the water level in dual reservoir system simulation, demonstrates the simplicity of the operation and design while maintaining the best performances. (author)

  8. A formal safety analysis for PLC software-based safety critical system using Z

    Koh, Jung Soo

    1997-02-01

    This paper describes a formal safety analysis technique which is demonstrated by performing empirical formal safety analysis with the case study of beamline hutch door Interlock system that is developed by using PLC (Programmable Logic Controller) systems at the Pohang Accelerator Laboratory. In order to perform formal safety analysis, we have built the Z formal specifications representation from user requirement written in ambiguous natural language and target PLC ladder logic, respectively. We have also studied the effective method to express typical PLC timer component by using specific Z formal notation which is supported by temporal history. We present a formal proof technique specifying and verifying that the hazardous states are not introduced into ladder logic in the PLC-based safety critical system. And also, we have found that some errors or mismatches in user requirement and final implemented PLC ladder logic while analyzing the process of the consistency and completeness of Z translated formal specifications. In the case of relatively small systems like Beamline hutch door interlock system, a formal safety analysis including explicit proof is highly recommended so that the safety of PLC-based critical system may be enhanced and guaranteed. It also provides a helpful benefits enough to comprehend user requirement expressed by ambiguous natural language

  9. Optical interconnection for a polymeric PLC device using simple positional alignment.

    Ryu, Jin Hwa; Kim, Po Jin; Cho, Cheon Soo; Lee, El-Hang; Kim, Chang-Seok; Jeong, Myung Yung

    2011-04-25

    This study proposes a simple cost-effective method of optical interconnection between a planar lightwave circuit (PLC) device chip and an optical fiber. It was conducted to minimize and overcome the coupling loss caused by lateral offset which is due to the process tolerance and the dimensional limitation existing between PLC device chips and fiber array blocks with groove structures. A PLC device chip and a fiber array block were simultaneously fabricated in a series of polymer replication processes using the original master. The dimensions (i.e., width and thickness) of the under-clad of the PLC device chip were identical to those of the fiber array block. The PLC device chip and optical fiber were aligned by simple positional control for the vertical direction of the PLC device chip under a particular condition. The insertion loss of the proposed 1 x 2 multimode optical splitter device interconnection was 4.0 dB at 850 nm and the coupling loss was below 0.1 dB compared with single-fiber based active alignment.

  10. Arbitration Award of ICSID on the Investment Disputes of Churchill Mining PLC v. Republic of Indonesia

    Yordan Gunawan

    2017-03-01

    Full Text Available The research is aimed at analyzing the ICSID (International Centre Settlement Investment Dispute decision in solving a dispute between Churchill Mining PLC and the Government of the Republic of Indonesia. The case brought to the public attention, because mining license owned by PT. Ridlatama which acquired from Churchill Mining PLC had been revocated. Churchill Mining PLC holds 75% share of PT. Ridlatama and it suffered losses caused by the revocation of its mining license. Churchill Mining PLC filed the case to the local court but it failed. Churchill Mining PLC then sought ruling from International arbitration or ICSID. On December 6, 2016, ICSID issued a decision that clearly threw out Churchill Mining PLC claim. ICSID, the World Bank court, ordered the firm to pay a total of US$.9.446.528 in cost to the Government of the Republic of Indonesia. It is based on the evidences that the UK-Australia company did the fraud and had document forgery of coal mining permit in East Kutai, Indonesia. So the firm has violated the Bilateral Investment Treaties between Indonesia-UK and Indonesia-Australia.

  11. Virtual Modular Redundancy of Processor Module in the PLC

    Lee, Kwang-Il; Hwang, SungJae; Yoon, DongHwa

    2016-01-01

    Dual Modular Redundancy (DMR) is mainly used to implement these safety control systems. DMR is conveyed when components of a system are duplicated, providing another component in case one should fault or fail. This feature has a high availability and large fault tolerant. It provides zero downtime that is required for nuclear power plants. So nuclear power plant has been commercialized by multiple redundant systems. The following paper, we propose a Virtual Modular Redundancy (VMR) rather than physical triple of the Programmable Logic Controller (PLC) processor module to ensure the reliability of the nuclear power plant control system. VMR implementation minimizes design changes to continue to use the commercially available redundant system. Also, the purpose of the VMR is to improve the efficiency and reliability in many ways, such as fault tolerant and fail-safe and cost. VMR guarantees a wide range of reliable fault recovery, fault tolerance, etc. It is prevented before it causes great damages due to the continuous failure of the two modules. The reliable communication speed is slow and also it has a small bandwidth. It is a great loss in the safety control system. However, VMR aims to avoid nuclear power plants that were suspended due to fail-safe. It is not for the purpose of commonly used. Application of VMR is actually expected to require a lot of research and trial and error until they adapt to the nuclear regulatory and standards

  12. Virtual Modular Redundancy of Processor Module in the PLC

    Lee, Kwang-Il; Hwang, SungJae; Yoon, DongHwa [SOOSAN ENS Co., Seoul (Korea, Republic of)

    2016-10-15

    Dual Modular Redundancy (DMR) is mainly used to implement these safety control systems. DMR is conveyed when components of a system are duplicated, providing another component in case one should fault or fail. This feature has a high availability and large fault tolerant. It provides zero downtime that is required for nuclear power plants. So nuclear power plant has been commercialized by multiple redundant systems. The following paper, we propose a Virtual Modular Redundancy (VMR) rather than physical triple of the Programmable Logic Controller (PLC) processor module to ensure the reliability of the nuclear power plant control system. VMR implementation minimizes design changes to continue to use the commercially available redundant system. Also, the purpose of the VMR is to improve the efficiency and reliability in many ways, such as fault tolerant and fail-safe and cost. VMR guarantees a wide range of reliable fault recovery, fault tolerance, etc. It is prevented before it causes great damages due to the continuous failure of the two modules. The reliable communication speed is slow and also it has a small bandwidth. It is a great loss in the safety control system. However, VMR aims to avoid nuclear power plants that were suspended due to fail-safe. It is not for the purpose of commonly used. Application of VMR is actually expected to require a lot of research and trial and error until they adapt to the nuclear regulatory and standards.

  13. Connecting programmable logic controllers (PLC) to control and data acquisition a comparison of the JET and Wendelstein 7-X approach

    Hennig, Christine; Kneupner, Klaus; Kinna, David

    2012-01-01

    Highlights: ► We describe 2 ways connecting PLCs to fusion control and data acquisition software. ► At W7-X standardization of the PLC type eases the maintenance of the software. ► At JET PLCs are interfaced with a daemon that hides the PLC specific part. ► There is potential to unify the approaches towards a common fusion PLC interface. - Abstract: The use of programmable logic controllers (PLC) for automation of electromechanical processes is an industrial control system technology. It is more and more in use within the fusion community. Traditionally PLC based systems are operated and maintained using proprietary SCADA systems (supervisory control and data acquisition). They are hardly ever integrated with the fusion control and data acquisition systems. An overview of the state of the art in fusion is given in the article. At JET an inhouse “black box protocol” approach has been developed to communicate with any external system via a dedicated http based protocol. However, a PLC usually cannot be modified to implement this special protocol. Hence, a software layer has been developed that interfaces a PLC by implementing the PLC specific communication part on one side and the black box protocol part on the other side. The software is completely data driven i.e. editing the data structure changes the logic accordingly. It can be tested using the web capability of the black box protocol. Multiple PLC types from different vendors are supported, thus multiple protocols to interface the PLC are in use. Depending on the PLC type and available tools it can be necessary to program the PLC accordingly. Wendelstein 7-X uses another approach. For every single PLC a dedicated communication from and to CoDaC is implemented. This communication is projected (programmed) in the PLC and configurable (data driven) on the CoDaC side. The protocol is UDP based and observed via timeout mechanisms. The use of PLCs for Wendelstein 7-X is standardized. Therefore a single

  14. Connecting programmable logic controllers (PLC) to control and data acquisition a comparison of the JET and Wendelstein 7-X approach

    Hennig, Christine, E-mail: Christine.Hennig@ipp.mpg.de [Max-Planck-Institut fuer Plasmaphysik, Wendelsteinstrasse 1, 17491 Greifswald (Germany); Kneupner, Klaus; Kinna, David [JET-EFDA, Culham Science Centre, OX14 3DB Abingdon (United Kingdom)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer We describe 2 ways connecting PLCs to fusion control and data acquisition software. Black-Right-Pointing-Pointer At W7-X standardization of the PLC type eases the maintenance of the software. Black-Right-Pointing-Pointer At JET PLCs are interfaced with a daemon that hides the PLC specific part. Black-Right-Pointing-Pointer There is potential to unify the approaches towards a common fusion PLC interface. - Abstract: The use of programmable logic controllers (PLC) for automation of electromechanical processes is an industrial control system technology. It is more and more in use within the fusion community. Traditionally PLC based systems are operated and maintained using proprietary SCADA systems (supervisory control and data acquisition). They are hardly ever integrated with the fusion control and data acquisition systems. An overview of the state of the art in fusion is given in the article. At JET an inhouse 'black box protocol' approach has been developed to communicate with any external system via a dedicated http based protocol. However, a PLC usually cannot be modified to implement this special protocol. Hence, a software layer has been developed that interfaces a PLC by implementing the PLC specific communication part on one side and the black box protocol part on the other side. The software is completely data driven i.e. editing the data structure changes the logic accordingly. It can be tested using the web capability of the black box protocol. Multiple PLC types from different vendors are supported, thus multiple protocols to interface the PLC are in use. Depending on the PLC type and available tools it can be necessary to program the PLC accordingly. Wendelstein 7-X uses another approach. For every single PLC a dedicated communication from and to CoDaC is implemented. This communication is projected (programmed) in the PLC and configurable (data driven) on the CoDaC side. The protocol is UDP based and

  15. Evaluation of PLC Channel Capacity and ABER Performances for OFDM-Based Two-Hop Relaying Transmission

    Ezzine, Sana; Abdelkefi, Fatma; Cances, Jean Pierre; Meghdadi, Vahid; Bouallégue, Ammar

    2017-01-01

    Powerline network is recognized as a favorable infrastructure for Smart Grid to transmit information in the network thanks to its broad coverage and low cost deployment. The existing works are trying to improve and adapt transmission techniques to reduce Powerline Communication (PLC) channel attenuation and exploit the limited bandwidth to support high data rate over long distances. Two-hop relaying BroadBand PLC (BB-PLC) system, in which Orthogonal Frequency Division Multiplexing (OFDM) is u...

  16. The Design and Realization of Virtual Machine of Embedded Soft PLC Running System

    Qingzhao Zeng

    2014-11-01

    Full Text Available Currently soft PLC has been the focus of study object for many countries. Soft PLC system consists of the developing system and running system. A Virtual Machine is an important part in running system even in the whole soft PLC system. It explains and performs intermediate code generated by the developing system and updates I/O status of PLC in order to complete its control function. This paper introduced the implementation scheme and execution process of the embedded soft PLC running system Virtual Machine, and mainly introduced its software implementation method, including the realization of the input sampling program, the realization of the instruction execution program and the realization of output refresh program. Besides, an operation code matching method was put forward in the instruction execution program design. Finally, the test takes PowerPC/P1010 (Freescale as the hardware platform and Vxworks as the operating system, the system test result shows that accuracy, the real-time performance and reliability of Virtual Machine.

  17. PLC and DTAM Software Programs for Pumping Instrumentation and Control Skid N

    KOCH, M.R.

    2000-01-01

    This document describe the software programs for the Programmable Logic Controller and the Datable Access Module for Pumping Instrumentation and Control skid ''N''. The Appendices contains copies of the printouts of these software programs. This document describes the software programs for the Allen-Bradley SLC 500 programmable logic controller (PLC) and the Allen-Bradley DTAM PLUS operator interface module used on Pumping Instrumentation and Control (PIC) skid ''N''. The software programs for the SLC 500 and DTAM Plus are based on the core programs provided by Allen-Bradley. The PLC and DTAM software programs on skid ''D'' for SX-104 are the baseline programs. These baselines have been tailored for U-farm skids. The skid ''N'' program for U-109 is similar to the skid ''M'' program for U-102. An Acceptance Test Procedure (ATP) and an Operational Test Procedure (OTP) verify that the software programs meet the specific requirements for U-109 pumping. This document represents the final PLC and DTAM programs for PIC skid ''N'' at U-109. These programs were printed out after the performance of the OTP. The OTP acts as the final qualification test for the software programs. Functional requirements and details of the PLC ladder logic are described in this document. The final programs entered into the PLC and DTAM Plus are included as Appendices to this document

  18. Realizace úzkopásmových PLC modemů

    Kubíček, Lukáš

    2012-01-01

    Diplomová práce se věnuje úzkopásmové technologii přenosu dat el. sítí NN (PLC) a~možnostem jejího využití v senzorových sítích. Zabývá se jak strukturou a základními vlastnostmi PLC standardu, tak možnostmi jeho uplatnění v praxi. Hlavní částí této práce je realizace PLC sítě pomocí IO ST7570 firmy STMicroelectronics. Jako příklad praktického využití PLC technologie je tato síť připojena k počítači, ve kterém jsou data ze senzoru (wattmetru) připojenému k PLC modemu ukládána pomocí aplikace ...

  19. PLC-based mode multi/demultiplexers for mode division multiplexing

    Saitoh, Kunimasa; Hanzawa, Nobutomo; Sakamoto, Taiji; Fujisawa, Takeshi; Yamashita, Yoko; Matsui, Takashi; Tsujikawa, Kyozo; Nakajima, Kazuhide

    2017-02-01

    Recently developed PLC-based mode multi/demultiplexers (MUX/DEMUXs) for mode division multiplexing (MDM) transmission are reviewed. We firstly show the operation principle and basic characteristics of PLC-based MUX/DEMUXs with an asymmetric directional coupler (ADC). We then demonstrate the 3-mode (2LP-mode) multiplexing of the LP01, LP11a, and LP11b modes by using fabricated PLC-based mode MUX/DEMUX on one chip. In order to excite LP11b mode in the same plane, a PLC-based LP11 mode rotator is introduced. Finally, we show the PLC-based 6-mode (4LP-mode) MUX/DEMUX with a uniform height by using ADCs, LP11 mode rotators, and tapered waveguides. It is shown that the LP21a mode can be excited from the LP11b mode by using ADC, and the two nearly degenerated LP21b and LP02 modes can be (de)multiplexed separately by using tapered mode converter from E13 (E31) mode to LP21b (LP02) mode.

  20. Separation of integrin-dependent adhesion from morphological changes based on differential PLC specificities.

    Wooten, D K; Teague, T K; McIntyre, B W

    1999-01-01

    In normal lymphocytes an inside-out signal up-regulating integrin adhesion is followed by a ligand-mediated outside-in cell spreading signal. Protein kinase C (PKC) inhibition blocks lymphocyte adherence to and spreading on fibronectin. In contrast, putative PLC inhibitors yield distinct differences with respect to adhesion and morphology. The phosphatidylinositol-specific phospholipase C (PLC) inhibitor neomycin blocked spreading of CD3/CD28-activated T cells on fibronectin by disrupting adhesion. Furthermore, when an additional inside-out signal for fibronectin adhesion is unnecessary such as with HPB-ALL T leukemic or phorbol-myristate-acetate-treated normal T cells, neomycin treatment does not alter adhesion or morphology. However, the phosphatidylcholine-specific PLC inhibitor D609 abrogates cell spreading without affecting adhesion to fibronectin in these cells as well as the CD3/CD28-activated T cells. These results strongly suggest that inside-out signaling for the integrin alpha4beta1 in lymphocytes proceeds through phosphatidylinositol-specific PLC and PKC, whereas the outside-in signal utilizes phosphatidylcholine-specific PLC and PKC.

  1. An Architecture Of Plc Ls Xbc-Dr30e Based Clean Water Controlling System

    M.Jusuf Jamanawar Purba

    2017-12-01

    Full Text Available In the industrial field the good controlling system is definitely required to improve the working efficiency of a system. The type of controller PLC Programmable Logic Controller used in Clean Water Controlling System in Electrical Workshop with PLC LS XBC-DR30E. Furthermore such system consistently uses two types of component they are Relay and Timer. The clean water pump control aims to pump the water in well A to storage tank B. The pump will work when water-contained well A is marked by sensor level well A on and the water inside storage tank B is under level 3. When the water inside storage tank B is under level 2 both pumps M1 and M2 will work to fill storage tank B. on the contrary when storage tank B is above level 2 only one pump M1 works until the tank reach level 3. In addition when storage tank B is above level 3 both pumps will stop working. However along with the advancement of recent technology the above system can be controlled by using PLC Programmable Logic Controller. Therefore it is possible to apply the controlling method of PLC as the semester Vs practical module. Based on the trial performed the PLC-based clean water system is well-functioned as the working description compiled before the operation of the tool.

  2. PLC/DTAM Software Programs for Pumping Instrumentation and Control Skid X

    HORNER, T.M.

    2001-01-01

    This document describes the software programs for the Allen-Bradley SLC 500 programmable logic controller (PLC) and the Allen-Bradley DTAM PLUS operator interface module used on Pumping Instrumentation and Control (PIC) skid ''X''. The software programs for the SLC 500 and DTAM Plus are based on the core programs provided by Allen-Bradley. The PLC and DTAM software programs on skid ''D'' for SX-104 are the baseline programs. These baselines will be tailored for each individual BY-farm skid. An Acceptance Test Procedure (ATP) and an Operational Test Procedure (OTP) verify that the software programs meet the specific requirements for BY-105 pumping. This document represents the final PLC and DTAM programs for PIC skid ''X'' at BY-105. These programs were printed out after the performance of the OTP. The OTP acts as the final qualification test for the software programs. Functional requirements and details of the PLC ladder logic are described in this document. The final programs entered into the PLC and DTAM Plus are included as Appendices to this document

  3. Cable line engineering

    Jang, Hak Sin; Kim, Sin Yeong

    1998-02-01

    This book is about cable line engineering. It is comprised of nine chapters, which deals with summary of cable communication such as way, process of cable communication and optical communication, Line constant of transmission on primary constant, reflection and crosstalk, communication cable line of types like flat cable, coaxial cable and loaded cable, Install of communication line with types and facility of aerial line, construction method of communication line facility, Measurement of communication line, Carrier communication of summary, PCM communication with Introduction, regeneration relay system sampling and quantization and Electric communication service and general information network with mobile communication technique and satellite communication system.

  4. Development of Safety Grade PLC (POSAFE-Q) and Performance Test Results

    Kim, Chang Hwoi; Park, Won Man; Choi, Jong Gyun; Lee, Dong Young [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); No, Young Hun; Song, Seung Hwan [POSCON, Seoul (Korea, Republic of)

    2006-07-01

    The safety grade PLC (POSAFE-Q) is being developed in the Korea Nuclear Instrumentation and Control System (KNICS) R and D project. The PLC satisfies Safety Class 1E, Quality Class 1, and Seismic Category I. The software such as the RTOS and firmware are being developed according to the safety critical software life cycle. Especially, the formal method is applied to design the SRS (Software Requirement Spec.) and the SDS (Software Design Specification.) to be error-free. The POSAFE-Q has several modules such as processor module, input and output modules, communication modules, redundant processor module, redundant power modules, etc,. To verify the function and performance, several tests such as CT, IT and ST were performed. And also, the equipment qualification test for environment, EMI and EMC, and seismic ware performed. All tests are satisfied with the requirements and specification for safety grade PLC, and the criteria for safety system in nuclear power plants.

  5. MultiController: the PLC-SCADA object for advanced regulation

    Ortola, J

    2007-01-01

    Nowadays, industrial solutions with PLCs (Programmable Logic Controllers) have basic control loop features. The SCADA (Supervisory Control And Data Acquisition) system is a key point of the process control system due to an efficient HMI (Human Machine Interfaces) that provides an open method of tuning and leading possibilities. As a consequence, advanced control algorithms have to be developed and implemented for those PLC-SCADA solutions in order to provide perspectives in solving complex and critical regulation problems. The MultiController is an object integrated for a large scale project at CERN (the European Organization for Nuclear Research) named LHC-GCS (Large Hadron Collider - Gas Control System). It is developed for a Framework called CERN-UNICOS based on PLC-SCADA facilities. The MultiController object offers various advanced control loop strategies. It gives to the user advanced control algorithms like PID, Smith Predictor, PFC, GPC and RST. It is implemented as a monolithic entity (in PLC and SCA...

  6. Design and implementation of tutorials for PLC B&R Automation

    Sýkora, Daniel

    2014-01-01

    Tato bakalářská práce se zabývá návrhem a realizací úloh pro PLC B&R a podrobným návodem práce v Automation Studio. Obsahuje také informace o firmě B&R Automation Ges. m. b. H. a jejích produktech. Návrh úloh probíhal ve vývojovém prostředí B&R Automation Studio. Praktická úloha na regulaci teploty byla řešena a odzkoušena na B&R PLC X20. This bachelor’s thesis deals with the design and the implementation tutorials for PLC B&R as well as the detailed instructions of work in the Automation ...

  7. Reliability Analysis of Safety Grade PLC(POSAFE-Q) for Nuclear Power Plants

    Kim, J. Y.; Lyou, J.; Lee, D. Y.; Choi, J. G.; Park, W. M.

    2006-01-01

    The Part Count Method of the military standard MILHDK- 217F has been used for the reliability prediction of the nuclear field. This handbook determines the Programmable Logic Controller (PLC) failure rate by summing the failure rates of the individual component included in the PLC. Normally it is easily predictable that the components added for the fault detection improve the reliability of the PLC. But the application of this handbook is estimated with poor reliability because of the increased component number for the fault detection. To compensate this discrepancy, the quantitative reliability analysis method is suggested using the functional separation model in this paper. And it is applied to the Reactor Protection System (RPS) being developed in Korea to identify any design weak points from a safety point of view

  8. Bringing Automated Model Checking to PLC Program Development - A CERN Case Study

    Fernandez Adiego, B; Tournier, J-C; Blanco Vinuela, E; Gonzalez Suarez, V M

    2014-01-01

    Verification of critical software is a high priority but a challenging task for industrial control systems. Model checking appears to be an appropriate approach for this purpose. However, this technique is not widely used in industry yet, due to some obstacles. The main obstacles encountered when trying to apply formal verification techniques at industrial installations are the difficulty of creating models out of PLC programs and defining formally the specification requirements. In addition, models produced out of real-life programs have a huge state space, thus preventing the verification due to performance issues. Our work at CERN (European Organization for Nuclear Research) focuses on developing efficient automatic verification methods for industrial critical installations based on PLC (Programmable Logic Controller) control systems. In this paper, we present a tool generating automatically formal models out of PLC code. The tool implements a general methodology which can support several input languages, ...

  9. Technical considerations for the development of an engineering safety features control system with PLC

    Lee, C. K.; Kim, C. H.; Han, J. B.; Kim, H.; Lee, S. S.

    2002-01-01

    Technical considerations are summarized for the development of an ESFCS(Engineered Safety Features Control System) with PLC (Programmable Logic Controller). The ESFCS is required for the mitigation of plant accident conditions and therefore developed in conformance with the design requirements applied to the safety critical system. The design of ESFCS primarily considered its safety, and the system has an architecture that will be able to minimize spurious actuation. The PLC based functional distribution and redundant design features are adopted, and the fieldbus is applied in the communication of information and control signals between PLC processors. It is expected that the ESFCS will have several advanced design features compared with the conventional systems supplied by foreign vendors

  10. Development of Safety Grade PLC (POSAFE-Q) and Performance Test Results

    Kim, Chang Hwoi; Park, Won Man; Choi, Jong Gyun; Lee, Dong Young; No, Young Hun; Song, Seung Hwan

    2006-01-01

    The safety grade PLC (POSAFE-Q) is being developed in the Korea Nuclear Instrumentation and Control System (KNICS) R and D project. The PLC satisfies Safety Class 1E, Quality Class 1, and Seismic Category I. The software such as the RTOS and firmware are being developed according to the safety critical software life cycle. Especially, the formal method is applied to design the SRS (Software Requirement Spec.) and the SDS (Software Design Specification.) to be error-free. The POSAFE-Q has several modules such as processor module, input and output modules, communication modules, redundant processor module, redundant power modules, etc,. To verify the function and performance, several tests such as CT, IT and ST were performed. And also, the equipment qualification test for environment, EMI and EMC, and seismic ware performed. All tests are satisfied with the requirements and specification for safety grade PLC, and the criteria for safety system in nuclear power plants

  11. An advanced lab frame PC-PLC regime for a power supply control

    Abdel-Bary, M

    2010-01-01

    A lab frame automatic control system (LFACS) based on a programmable logic controller (PLC) is designed, developed and tested in the laboratory. The LFACS is designed to control and monitor one DC power supply with output current accuracy 0.001 amps, one automatic valve. Also the LFACS will monitor one full range vacuum measurement and one water leak detector. The control system is built based on the internationally standard programmable logic controller (PLC) from Siemens. Two software's have been used; firstly SIMATIC S 7 lite has been used to build the control program and safety interlocks, secondly winCC flexible (runs in a PC computer and communicates with the PLC by multi point interface PC adapter (MPI) has been used to build the user-machine interface . This lab frame control system will be generalized to a global control system to control the MGC-20 cyclotron. The lab tests showed a reliable and flexible control system.

  12. Design and Implementation of PLC-Based Automatic Sun tracking System for Parabolic Trough Solar Concentrator

    Wang Jinping

    2016-01-01

    Full Text Available A sun-tracking system for parabolic trough solar concentrators (PTCs is a control system used to orient the concentrator toward the sun always, so that the maximum energy can be collected. The work presented here is a design and development of PLC based sun tracking control system for PTC. Sun tracking control system consists of a Programmable Logic Controller (PLC and a single axis hydraulic drives tracking control system. Hydraulic drives and the necessary tracking angle algorithm have been designed and developed to perform the technical tasks. A PLC unit was employed to control and monitor the mechanical movement of the PTC and to collect and store data related to the tracking angle of PTC. It is found that the tracking error of the system is less than 0.6°. Field experience shows that tracking algorithm act stable and reliable and suit for PTCs.

  13. Expression of the hepatitis B virus genome in chronic hepatitis B carriers and patients with hepatocellular carcinoma

    Bowyer, S.M.; Dusheiko, G.M.; Schoub, B.D.; Kew, M.C.

    1987-01-01

    The authors examined the methylation status of CCGG sites in hepatitis B virus (HBV) DNA to determine whether methylation could be responsible for the selective expression of the HBV surface gene in chronic hepatitis B infection and hepatocellular carcinoma. Infected liver tissue from patients with low levels of viral replication was analyzed for HBV DNA copy number per haploid cell genome. Total cellular DNA, with sufficient HBV DNA, was digested with the restriction endonucleases Msp I and Hpa II, to determine whether the HBV DNA was methylated, or HindIII, to determine whether the HBV DNA was integrated or episomal. The cleavage fragments were analyzed by Southern blotting and hybridization to 32 P-labeled HBV DNA. In replicative chronic hepatitis B, hypomethylation of the HBV genome correlated with HBV expression in both virions and infected tissue. In carriers with nonreplicative infection, it was difficult to ascertain the role of methylation as copy number was low. HBV DNA copy number was also low in 17 out of 29 of the rumor tissues tested and as many as 14 out of 16 of the adjacent non-neoplastic tissues tested. Integrated sequences were hypermethylated in the PLC/PRF/5 cell line and in six of the tumor tissues suggesting that methylation plays a role in HBV gene repression. However, since DNA from five other tumors was hypomethylated, the belief that methylation per se is an absolute determinant of HBV core gene repression does not hold for human hepatocellular carcinoma tissue

  14. Construction and Verification of PLC LD-programs by LTL-specification

    E. V. Kuzmin

    2013-01-01

    Full Text Available An approach to construction and verification of PLC LD-programs for discrete problems is proposed. For the specification of the program behavior, we use the linear-time temporal logic LTL. Programming is carried out in the LD-language (Ladder Diagram according to an LTL-specification. The correctness analysis of an LTL-specification is carried out by the symbolic model checking tool Cadence SMV. A new approach to programming and verification of PLC LD-programs is shown by an example. For a discrete problem, we give a LD-program, its LTL-specification and an SMV-model. The purpose of the article is to describe an approach to programming PLC, which would provide a possibility of LD-program correctness analysis by the model checking method. Under the proposed approach, the change of the value of each program variable is described by a pair of LTL-formulas. The first LTL-formula describes situations which increase the value of the corresponding variable, the second LTL-formula specifies conditions leading to a decrease of the variable value. The LTL-formulas (used for speci- fication of the corresponding variable behavior are constructive in the sense that they construct the PLC-program (LD-program, which satisfies temporal properties expressed by these formulas. Thus, the programming of PLC is reduced to the construction of LTLspecification of the behavior of each program variable. In addition, an SMV-model of a PLC LD-program is constructed according to LTL-specification. Then, the SMV-model is analysed by the symbolic model checking tool Cadence SMV.

  15. Comparison of the effect of interferon on two human hepatoma cell lines

    Crespi, M; Schoub, B D; Lyons, S F; Chiu, M N [University of the Witwatersrand, Johannesburg (South Africa). Dept. of Virology

    1985-06-01

    Two human hepatoma cell lines, the PLC/PRF/5 and the Mahlavu cells, which differ in their production of the hepatitis B surface antigen (HBsAg), responded differently to interferon (IFN). After IFN treatment both cell lines were able to inhibit Sindbis virus replication. Oligo A synthetase (E enzyme) could be activated in the PLC/PRF/5 cells although they were not sensitive to exogenous 2 - 5 oligoadenylic acid (2 - 5 A). In contrast, the Mahlavu cells were sensitive to exogenous 2 - 5 A, but unable to activate the E enzyme. Both cell lines were unable to stimulate phosphorylation of the exogenous initiator factor eIF-2.

  16. The Research about Embedded Soft PLC Running System Based on ARM

    Fang Ding

    2014-09-01

    Full Text Available The paper discusses the overall construction and operational principle of soft PLC. Considering the real time request of the system, we use Linux+RTAI dual core system as software platform. In this platform, the implementation method of soft PLC operational system is introduced. Especially, the design of instruction analysis module is emphasized. On the basis of energy flow concept, the logic algorithm is established, aligning to the left bus. Finally, the system is tested to evaluate the desired control behavior.

  17. A fast PID controller Design for Modern PLC for Process Control Application

    Mirza, A.; Nafis, A.; Anees, R.M.; Idris, S.

    2004-01-01

    PID is the most widely used control scheme in the process industry. Pill controllers are utilized for the control of such varied parameters as pressure, flow, temperature, etc. One characteristic of these parameters is that they posses slow dynamics. Most of the available digital controllers can manipulate only a single parameter- multiple controllers are required for control of more than one parameter. The Fast PID Controller for Modem PLC (Programmable Logic Controller) developed by the authors, provides control of several parameters at a time (through a single Pill control element), enhanced programmability including variable sampling period, parameter monitoring and data storage, which may be easily implemented in a PLC. (author)

  18. An Integrated Software Development Framework for PLC and FPGA based Digital I and Cs

    Yoo, Jun Beom; Kim, Eui Sub; Lee, Dong Ah; Choi, Jong Gyun

    2014-01-01

    NuDE 2.0 (Nuclear Development Environment) is a model-based software development environment for safety- critical digital systems in nuclear power plants. It makes possible to develop PLC-based systems as well as FPGA-based systems simultaneously from the same requirement or design specifications. The case study showed that the NuDE 2.0 can be adopted as an effective method of bridging the gap between the existing PLC and upcoming FPGA-based developments as well as a means of gaining diversity

  19. PLC-based LP₁₁ mode rotator for mode-division multiplexing transmission.

    Saitoh, Kunimasa; Uematsu, Takui; Hanzawa, Nobutomo; Ishizaka, Yuhei; Masumoto, Kohei; Sakamoto, Taiji; Matsui, Takashi; Tsujikawa, Kyozo; Yamamoto, Fumihiko

    2014-08-11

    A PLC-based LP11 mode rotator is proposed. The proposed mode rotator is composed of a waveguide with a trench that provides asymmetry of the waveguide. Numerical simulations show that converting LP11a (LP11b) mode to LP11b (LP11a) mode can be achieved with high conversion efficiency (more than 90%) and little polarization dependence over a wide wavelength range from 1450 nm to 1650 nm. In addition, we fabricate the proposed LP11 mode rotator using silica-based PLC. It is confirmed that the fabricated mode rotator can convert LP11a mode to LP11b mode over a wide wavelength range.

  20. An Integrated Software Development Framework for PLC and FPGA based Digital I and Cs

    Yoo, Jun Beom; Kim, Eui Sub; Lee, Dong Ah [Konkuk University, Seoul (Korea, Republic of); Choi, Jong Gyun [KAERI, Daejeon (Korea, Republic of)

    2014-08-15

    NuDE 2.0 (Nuclear Development Environment) is a model-based software development environment for safety- critical digital systems in nuclear power plants. It makes possible to develop PLC-based systems as well as FPGA-based systems simultaneously from the same requirement or design specifications. The case study showed that the NuDE 2.0 can be adopted as an effective method of bridging the gap between the existing PLC and upcoming FPGA-based developments as well as a means of gaining diversity.

  1. One-way data transfer for PLC to VME status reporting at the Advanced Photon Source

    Stein, S.J.

    1993-01-01

    The Personnel Safety System for the experimental beamlines at the Advanced Photon Source will use a large number of Allen Bradley Programmable Logic Controllers (PLC) to replace conventional relay logic. PLCs allow for the design of a very advanced safety system that can handle a large number of I/O points. Certain situations Require monitoring of the safety system from various locations around the storage ring via EPICS OPI (operator interface)consoles. This presentation covers the method of choice for transferring data from the Personnel Safety System into an EPICS database. Specifics on PLC ladder design, EPICS database design, and hardware selection are also discussed

  2. 75 FR 61361 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-535 Series Turbofan Engines

    2010-10-05

    ...-0994; Directorate Identifier 2009-NE-39-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR...-Royce plc., P.O. Box 31, Derby, DE24 8BJ, United Kingdom; Telephone: 011 44 1332 242424, Fax: 011 44... based on those comments. We will post all comments we receive, without change, to http://www.regulations...

  3. 76 FR 78805 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines

    2011-12-20

    ... Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines AGENCY: Federal Aviation... all Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines. This AD results from mandatory... inspection of the FOHE mounts. We did not change the AD based on this comment. Request To Add Requirement To...

  4. 76 FR 65997 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-535 Series Turbofan Engines

    2011-10-25

    ...-0994; Directorate Identifier 2009-NE-39-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR... Friday, except Federal holidays. For service information identified in this AD, contact Rolls-Royce plc.... Based on these figures, we estimate the cost of this proposed AD on U.S. operators to be $1,499,400. FAA...

  5. 75 FR 45560 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines

    2010-08-03

    ...-0755; Directorate Identifier 2010-NE-12-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR... based on engine thrust rating but now based on operating shaft speeds) introduced by Rolls- Royce. The...-Royce plc, P.O. Box 31, Derby, DE24 8BJ, United Kingdom: Telephone 44 (0) 1332 242424; fax 44 (0) 1332...

  6. 77 FR 10355 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines

    2012-02-22

    ... Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines AGENCY: Federal Aviation... service of certain critical engine parts based on reduced life limits. This new AD reduces the life limits... effective March 28, 2012. ADDRESSES: For service information identified in this AD, contact Rolls-Royce plc...

  7. 77 FR 4648 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-535 Series Turbofan Engine

    2012-01-31

    ... Airworthiness Directives; Rolls-Royce plc (RR) RB211-535 Series Turbofan Engine AGENCY: Federal Aviation... identified in this AD, contact Rolls-Royce plc, P.O. Box 31, Derby, DE24 8BJ, United Kingdom; phone: 011 44... parts are required. Based on these figures, we estimate the cost of this AD on U.S. operators to be $1...

  8. 75 FR 63727 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-524 Series Turbofan Engines

    2010-10-18

    ...-0162; Directorate Identifier 2004-NE-19-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR...-2251. Contact Rolls-Royce plc, P.O. Box 31, Derby, DE24 8BJ, United Kingdom; telephone: 011-44-1332... would cost $0. Based on these figures, we estimate the total cost of the AD to U.S. operators would be...

  9. 76 FR 68663 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines

    2011-11-07

    ...-0755; Directorate Identifier 2010-NE-12-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR... Rolls-Royce plc, Corporate Communications, P.O. Box 31, Derby, England, DE248BJ; phone: 011-44-1332... date and may amend this proposed AD based on those comments. We will post all comments we receive...

  10. 77 FR 1009 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-524 Series Turbofan Engines

    2012-01-09

    ... Airworthiness Directives; Rolls-Royce plc (RR) RB211-524 Series Turbofan Engines AGENCY: Federal Aviation... 5, 2005). ADDRESSES: For service information identified in this AD, contact Rolls-Royce plc, P.O...,000. Based on these figures, we estimate the total cost of the AD to U.S. operators to be $4,206,960...

  11. 75 FR 17630 - Airworthiness Directives; Rolls-Royce plc RB211 Trent 700 and Trent 800 Series Turbofan Engines

    2010-04-07

    ...-0364; Directorate Identifier 2009-NE-27-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc... based on those comments. We will post all comments we receive, without change, to http://www.regulations... Service Information Rolls-Royce plc has issued Alert Service Bulletin RB.211-72-AG086, dated December 4...

  12. 77 FR 21588 - Hart and Cooley, Inc., A Subsidiary of Tomkins, PLC Including On-Site Leased Workers from...

    2012-04-10

    ... Subsidiary of Tomkins, PLC Including On- Site Leased Workers from Reliable, Masiello Employment Services..., applicable to workers of Hart and Cooley, Inc., a subsidiary of Tomkins, PLC, including on-site leased... workers. Based on these findings, the Department is amending this certification to include workers leased...

  13. 76 FR 72650 - Airworthiness Directives; Rolls-Royce plc (RR) RB211 Trent 800 Series Turbofan Engines

    2011-11-25

    ...-0959; Directorate Identifier 2011-NE-25-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR... holidays. Fax: (202) 493-2251. Contact Rolls-Royce plc, P.O. Box 31, Derby, DE24 8BJ, United Kingdom; phone... AD. We will consider all comments received by the closing date and may amend this proposed AD based...

  14. The YvfTU Two-component System is involved in plcR expression in Bacillus cereus

    Brillard, Julien; Susanna, Kim; Michaud, Caroline; Dargaignaratz, Claire; Gohar, Michel; Nielsen-Leroux, Christina; Ramarao, Nalini; Kolsto, Anne-Brit; Nguyen-The, Christophe; Lereclus, Didier; Broussolle, Veronique

    2008-01-01

    Background: Most extracellular virulence factors produced by Bacillus cereus are regulated by the pleiotropic transcriptional activator PlcR. Among strains belonging to the B. cereus group, the plcR gene is always located in the vicinity of genes encoding the YvfTU two-component system. The putative

  15. 75 FR 34172 - Rexam Closure Systems, Inc., a Subsidiary of Rexam PLC, Including On-Site Leased Workers From...

    2010-06-16

    ... Illinois Manufacturing, Hamlet, NC; Amended Certification Regarding Eligibility To Apply for Worker... PLC, Hamlet, North Carolina. The notice was published in the Federal Register on April 23, 2010 (75 FR... at the Hamlet, North Carolina location of Rexam Closure Systems, Inc., a subsidiary of Rexam PLC. The...

  16. Biochemical characterization of the tomato phosphatidylinositol-specific phospholipase C (PI-PLC) family and its role in plant immunity

    Abd-El-Haliem, Ahmed; Vossen, J.H.; Zeijl, van Arjan; Dezhsetan, Sara; Testerink, Christa; Seidl, M.F.; Beck, Martina; Strutt, James; Robatzek, Silke; Joosten, M.H.A.J.

    2016-01-01

    Plants possess effective mechanisms to quickly respond to biotic and abiotic stresses. The rapid activation of phosphatidylinositol-specific phospholipase C (PLC) enzymes occurs early after the stimulation of plant immune-receptors. Genomes of different plant species encode multiple PLC homologs

  17. The Application of PLC (Powerline Communications) in Brazil in the regulatory viewpoint; A aplicacao do PLC no Brasil do ponto de vista regulatorio

    Vieira, Daniel; Silva Filho, Armando [Agencia Nacional de Energia Eletrica (ANEEL), Brasilia, DF (Brazil). Superintendencia de Regulacao dos Servicos de Distribuicao

    2010-07-01

    The Powerline Communications technology - PLC allows transmission of data, voice, image and access to high speed internet by the grid, so that a power plug can also be an access point to the network communication. Considering that the electric grid reaches the vast majority of households, there is great potential in using this technology as a tool to achieve the reality of digital inclusion in the country. However, its implementation must be accompanied by effective regulation, both through policies with respect to the conditions of use of radio frequencies, as in regulating the use of distribution networks of electricity as a means of transport for communication signal. In this context, the present article deals with the fundamental rules governing the application of PLC technology from the standpoint of the distributors and consumers of electricity, with attention to quality assurance of electrical energy and facility security.

  18. A Novel Method to Improve the Anticancer Activity of Natural-Based Hydroxyapatite against the Liver Cancer Cell Line HepG2 Using Mesoporous Magnesia as a Micro-Carrier

    Nasser S. Awwad; Ali M. Alshahrani; Kamel A. Saleh; Mohamed S. Hamdy

    2017-01-01

    Micro-carriers are the best known vehicles to transport different kinds of drugs to achieve high impact. In this study, mesoporous magnesium oxide has been harnessed as a micro-carrier to encapsulate the anticancer candidate drug natural-based cubic hydroxyapatite (HAP). HAP@MgO composites with different HAP loading (0–60 wt %), were prepared by a hydrothermal treatment method using triethanol amine as a template. The characterization of the prepared composites were achieved by using XRD, Ram...

  19. Improving a Power Line Communications Standard with LDPC Codes

    Hsu Christine

    2007-01-01

    Full Text Available We investigate a power line communications (PLC scheme that could be used to enhance the HomePlug 1.0 standard, specifically its ROBO mode which provides modest throughput for the worst case PLC channel. The scheme is based on using a low-density parity-check (LDPC code, in lieu of the concatenated Reed-Solomon and convolutional codes in ROBO mode. The PLC channel is modeled with multipath fading and Middleton's class A noise. Clipping is introduced to mitigate the effect of impulsive noise. A simple and effective method is devised to estimate the variance of the clipped noise for LDPC decoding. Simulation results show that the proposed scheme outperforms the HomePlug 1.0 ROBO mode and has lower computational complexity. The proposed scheme also dispenses with the repetition of information bits in ROBO mode to gain time diversity, resulting in 4-fold increase in physical layer throughput.

  20. A large number of stepping motor network construction by PLC

    Mei, Lin; Zhang, Kai; Hongqiang, Guo

    2017-11-01

    In the flexible automatic line, the equipment is complex, the control mode is flexible, how to realize the large number of step and servo motor information interaction, the orderly control become a difficult control. Based on the existing flexible production line, this paper makes a comparative study of its network strategy. After research, an Ethernet + PROFIBUSE communication configuration based on PROFINET IO and profibus was proposed, which can effectively improve the data interaction efficiency of the equipment and stable data interaction information.

  1. Applying Hamming Code to Memory System of Safety Grade PLC (POSAFE-Q) Processor Module

    Kim, Taehee; Hwang, Sungjae; Park, Gangmin

    2013-01-01

    If some errors such as inverted bits occur in the memory, instructions and data will be corrupted. As a result, the PLC may execute the wrong instructions or refer to the wrong data. Hamming Code can be considered as the solution for mitigating this mis operation. In this paper, we apply hamming Code, then, we inspect whether hamming code is suitable for to the memory system of the processor module. In this paper, we applied hamming code to existing safety grade PLC (POSAFE-Q). Inspection data are collected and they will be referred for improving the PLC in terms of the soundness. In our future work, we will try to improve time delay caused by hamming calculation. It will include CPLD optimization and memory architecture or parts alteration. In addition to these hamming code-based works, we will explore any methodologies such as mirroring for the soundness of safety grade PLC. Hamming code-based works can correct bit errors, but they have limitation in multi bits errors

  2. Trust and Collaboration in PLC Teams: Teacher Relationships, Principal Support, and Collaborative Benefits

    Hallam, Pamela R.; Smith, Henry R.; Hite, Julie M.; Hite, Steven J.; Wilcox, Bradley R.

    2015-01-01

    Professional learning communities (PLCs) are being recognized as effective in improving teacher collaboration and student achievement. Trust is critical in effectively implementing the PLC model, and the school principal is best positioned to influence school trust levels. Using five facets of trust, this research sought to clarify the impact of…

  3. A RESEARCH ON SEAMLESS PLATFORM CHANGE OF REACTOR PROTECTION SYSTEM FROM PLC TO FPGA

    JUNBEOM YOO

    2013-08-01

    Full Text Available The PLC (Programmable Logic Controller has been widely used to implement real-time controllers in nuclear RPSs (Reactor Protection Systems. Increasing complexity and maintenance cost, however, are now demanding more powerful and cost-effective implementation such as FPGA (Field-Programmable Gate Array. Abandoning all experience and knowledge accumulated over the decades and starting an all-new development approach is too risky for such safety-critical systems. This paper proposes an RPS software development process with a platform change from PLC to FPGA, while retaining all outputs from the established development. This paper transforms FBD designs of the PLC-based software development into a behaviorally-equivalent Verilog program, which is a starting point of a typical FPGA-based hardware development. We expect that the proposed software development process can bridge the gap between two software developing approaches with different platforms, such as PLC and FPGA. This paper also demonstrates its effectiveness using an example of a prototype version of a real-world RPS in Korea.

  4. A Remote PLC Laboratory (RLab) for Distance Practical Work of Industrial Automation

    Haritman, E.; Somantri, Y.; Wahyudin, D.; Mulyana, E.

    2018-02-01

    A laboratory is an essential equipment for engineering students to do a useful practical work. Therefore, universities should provide an adequate facility for practical work. On the other hand, industrial automation laboratory would offer students beneficial experience by using various educational PLC kits. This paper describes the development of Web-based Programmable Logic Controller (PLC) remote laboratory called RLab. It provides an environment for learners to study PLC application to control the level of the non-interacting tank. The RLab architecture is based on a Moodle and Remote Desktop, which also manages the booking system of the schedule of practical work in the laboratory. The RLab equipped by USB cameras providing a real-time view of PLC environment. To provide a secured system, the RLab combines Moodle and Remote Desktop application for the authentication system and management of remote users. Moodle will send PartnerID and password to connect to TeamViewer. It has been examined that the laboratory requirement, time and flexibility restrictions constitute a significant obstacle facing traditional students desiring to finish the course. A remote access laboratory can be eliminating time and flexibility restrictions. The preliminary study of RLab usability proved that such system is adequate to give the learners a distance practical work environment.

  5. 78 FR 20509 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-04-05

    ... Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed rulemaking...) RB211-535E4-B-37 series turbofan engines. This proposed AD was prompted by recalculating the life of.... (c) Applicability This AD applies to Rolls-Royce plc (RR) RB211-535E4-B-37 series turbofan engines...

  6. 78 FR 70487 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-11-26

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... turbofan engines. This AD requires removal of certain high-pressure (HP) and intermediate-pressure (IP..., RB211 Trent 768-60, 772-60, and 772B-60 turbofan engines with turbine disc part numbers (P/Ns) and...

  7. 77 FR 39157 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2012-07-02

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT...-84, and 980-84 turbofan engines. That AD currently requires inspecting the intermediate-pressure (IP... RR model RB211-Trent 970-84, 970B-84, 972-84, 972B-84, 977-84, 977B-84, and 980-84 turbofan engines...

  8. 78 FR 5 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-01-02

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT...-535E4-C-37 turbofan engines. This AD was prompted by an investigation by RR concluding that certain...- 535E4-B-37; RB211-535E4-B-75; and RB211-535E4-C-37 turbofan engines with intermediate-pressure (IP...

  9. 78 FR 37703 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-06-24

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... (RR) model RB211 Trent 768-60, 772-60, and 772B-60 turbofan engines. This AD was prompted by low...) model RB211 Trent 768-60, 772-60, and 772B-60 turbofan engines. (d) Reason This AD was prompted by low...

  10. 78 FR 70489 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-11-26

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT..., and 560A2-61 turbofan engines. This AD requires replacement or repair of the low-pressure (LP...-61, 556B2-61, 560-61, and 560A2-61 turbofan engines. (d) Reason This AD was prompted by reports of...

  11. 78 FR 22180 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-04-15

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... 972B-84, RB211-Trent 977-84, RB211-Trent 977B-84, and RB211-Trent 980-84 turbofan engines. This AD... 977B-84, and RB211-Trent 980-84 turbofan engines that incorporate RR production Modification 72-G585 or...

  12. 77 FR 20508 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2012-04-05

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT...-Trent 884B-17, RB211-Trent 892-17, RB211- Trent 892B-17, and RB211-Trent 895-17 turbofan engines. That...-17, RB211- Trent 892B-17, and RB211-Trent 895-17 turbofan engines. On September 9, 2011, we also...

  13. 77 FR 58762 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2012-09-24

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT...-Trent 892-17, RB211- Trent 892B-17, and RB211-Trent 895-17 turbofan engines. That AD currently requires...-17, RB211-Trent 892B-17, and RB211-Trent 895-17 turbofan engines. (d) Unsafe Condition This AD was...

  14. 78 FR 68360 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-11-14

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... turbofan engines. The AD number is incorrect in the Regulatory text. This document corrects that error. In... turbofan engines. As published, the AD number 2013-19-17 under Sec. 39.13 [Amended], is incorrect. No other...

  15. 78 FR 61171 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-10-03

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... (RR) RB211-535E4-B-37 series turbofan engines. This AD requires removal of affected parts using a...-B-37 series turbofan engines. (d) Unsafe Condition This AD was prompted by recalculating the lives...

  16. 78 FR 5126 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-01-24

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... turbofan engines. This AD requires replacement of the fuel oil heat exchanger (FOHE). This AD was prompted...-84 turbofan engines with a fuel oil heat exchanger (FOHE), part number 47111-1241, installed. (d...

  17. Automated Translation of Safety Critical Application Software Specifications into PLC Ladder Logic

    Leucht, Kurt W.; Semmel, Glenn S.

    2008-01-01

    The numerous benefits of automatic application code generation are widely accepted within the software engineering community. A few of these benefits include raising the abstraction level of application programming, shorter product development time, lower maintenance costs, and increased code quality and consistency. Surprisingly, code generation concepts have not yet found wide acceptance and use in the field of programmable logic controller (PLC) software development. Software engineers at the NASA Kennedy Space Center (KSC) recognized the need for PLC code generation while developing their new ground checkout and launch processing system. They developed a process and a prototype software tool that automatically translates a high-level representation or specification of safety critical application software into ladder logic that executes on a PLC. This process and tool are expected to increase the reliability of the PLC code over that which is written manually, and may even lower life-cycle costs and shorten the development schedule of the new control system at KSC. This paper examines the problem domain and discusses the process and software tool that were prototyped by the KSC software engineers.

  18. Design of a PLC control program for a batch plant : VHS case study 1

    Mader, A.H.; Brinksma, E.; Wupper, H.; Bauer, N.

    2001-01-01

    This article reports on the systematic design and validation of a PLC control program for the batch plant that has been selected as a case study for the EC project on Verification of Hybrid Systems (VHS). We show how a correct design of the control program can be obtained in an incremental manner

  19. Design of a PLC Control Program for a Batch Plant - VHS Case Study 1

    Mader, Angelika H.; Brinksma, Hendrik; Wupper, H.; Bauer, N.

    2001-01-01

    This article reports on the systematic design and validation of a PLC control program for the batch plant that has been selected as a case study for the EC project on Verification of Hybrid Systems (VHS). We show how a correct design of the control program can be obtained in an incremental manner

  20. A PLC generic requirements and specification for safety-related applications in nuclear power plants

    Han, Jea Bok; Lee, C. K.; Lee, D. Y.

    2001-12-01

    This report presents the requirements and specification to be applied to the generic qualification of programmable Logic Controller(PLC), which is being developed as part of the KNICS project, 'Development of the Digital Reactor Safety Systems' of which purpose is the application to safety-related instrumentation and control systems in nuclear power plants. This report defines the essential and critical characteristics that shall be included as part of a PLC design for safety-related application. The characteristics include performance, reliability, accuracy, the overall response time from an input to the PLC exceeding it trip condition to the resulting outputs, and the specification of processors and memories in digital controller. It also specifies the quality assurance process for software development, dealing with executive software, firmware, application software tools for developing the application software, and human machine interface(HMI). In addition, this report reviews the published standards and guidelines that are required for the PLC development and the quality assurance processes such as environment requirements, seismic withstand requirements, EMI/RFI withstand requirements, and isolation test

  1. Úzkopásmová PLC komunikace pro Smart Metering

    Kubů, Jiří

    2016-01-01

    Tato bakalářská práce se zabývá úzkopásmovou PLC komunikací. V práci je popsán základní princip, rozdělení PLC komunikace, historie technologie, využívané komunikační standardy a rušení ovlivňující datovou komunikaci této technologie. V rámci této práce byly provedeny i experimentální měření v reálném prostředí s modemy od firmy Texas Instruments C2000 PLC TMDSPLCKITV4 a C2000 PLC TMDSPLCKIT-V3. Výsledky tohoto měření jsou reálné přenosové rychlosti. Dále byla vytvořena aplikace pro dálkový s...

  2. 76 FR 1985 - Airworthiness Directives; Short Brothers PLC Model SD3 Airplanes

    2011-01-12

    ... Airworthiness Directives; Short Brothers PLC Model SD3 Airplanes AGENCY: Federal Aviation Administration (FAA..., at an average labor rate of $85 per work hour. Required parts cost about $10 per product. Based on.... The average labor rate is $85 per work-hour. Based on these figures, we estimate the cost of the AD on...

  3. 75 FR 15321 - Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines

    2010-03-29

    ... Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines AGENCY: Federal Aviation Administration... Based on the service information, we estimate that this AD will affect about 138 RB211 Trent 800 series... will cost about $2,000 per engine. Based on these figures, we estimate the cost of the AD on U.S...

  4. Applying Hamming Code to Memory System of Safety Grade PLC (POSAFE-Q) Processor Module

    Kim, Taehee; Hwang, Sungjae; Park, Gangmin [POSCO Nuclear Technology, Seoul (Korea, Republic of)

    2013-05-15

    If some errors such as inverted bits occur in the memory, instructions and data will be corrupted. As a result, the PLC may execute the wrong instructions or refer to the wrong data. Hamming Code can be considered as the solution for mitigating this mis operation. In this paper, we apply hamming Code, then, we inspect whether hamming code is suitable for to the memory system of the processor module. In this paper, we applied hamming code to existing safety grade PLC (POSAFE-Q). Inspection data are collected and they will be referred for improving the PLC in terms of the soundness. In our future work, we will try to improve time delay caused by hamming calculation. It will include CPLD optimization and memory architecture or parts alteration. In addition to these hamming code-based works, we will explore any methodologies such as mirroring for the soundness of safety grade PLC. Hamming code-based works can correct bit errors, but they have limitation in multi bits errors.

  5. Methods of Certification tests PLC-Networks in Compliance Safety Information

    A. A. Balaev

    2011-12-01

    Full Text Available The aim of this research was description of the methodology of the audit plc-network to meet the requirements of information security. The technique is based on the provisions of the guidance documents and model FSTEC Russia test object methods of information on safety information.

  6. 78 FR 65313 - Actavis, Inc. a corporation, and Warner Chilott PLC; Analysis of Agreement Containing Consent...

    2013-10-31

    ... FEDERAL TRADE COMMISSION [File No. 131 0152] Actavis, Inc. a corporation, and Warner Chilott PLC... https://ftcpublic.commentworks.com/ftc/actaviswarnerconsent following the instructions on the web-based....com/ftc/actaviswarnerconsent by following the instructions on the web-based form. If this Notice...

  7. A Research on Seamless Platform Change of Reactor Protection System From PLC to FPGA

    Yoo, Junbeom; Lee, Jonghoon [Konkuk Univ., Seoul (Korea, Republic of); Lee, Jangsoo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-08-15

    The PLC (Programmable Logic Controller) has been widely used to implement real-time controllers in nuclear RPSs (Reactor Protection Systems). Increasing complexity and maintenance cost, however, are now demanding more powerful and cost-effective implementation such as FPGA (Field-Programmable Gate Array). Abandoning all experience and knowledge accumulated over the decades and starting an all-new development approach is too risky for such safety-critical systems. This paper proposes an RPS software development process with a platform change from PLC to FPGA, while retaining all outputs from the established development. This paper transforms FBD designs of the PLC-based software development into a behaviorally-equivalent Verilog program, which is a starting point of a typical FPGA-based hardware development. We expect that the proposed software development process can bridge the gap between two software developing approaches with different platforms, such as PLC and FPGA. This paper also demonstrates its effectiveness using an example of a prototype version of a real-world RPS in Korea.

  8. Power supply system on HT-7 tokamak for diagnostic neutral beam based on PLC

    Zhang Jian; Liu Baohua; Ding Tonghai; Du Shaowu

    2006-01-01

    A power supply system for diagnostic neutral beam on the HT-7 Tokamak was developed. Its logic control system based on S7-300 PLC was described. The experimental results show that the system is easy to operate and its performance is reliable. (authors)

  9. A Research on Seamless Platform Change of Reactor Protection System From PLC to FPGA

    Yoo, Junbeom; Lee, Jonghoon; Lee, Jangsoo

    2013-01-01

    The PLC (Programmable Logic Controller) has been widely used to implement real-time controllers in nuclear RPSs (Reactor Protection Systems). Increasing complexity and maintenance cost, however, are now demanding more powerful and cost-effective implementation such as FPGA (Field-Programmable Gate Array). Abandoning all experience and knowledge accumulated over the decades and starting an all-new development approach is too risky for such safety-critical systems. This paper proposes an RPS software development process with a platform change from PLC to FPGA, while retaining all outputs from the established development. This paper transforms FBD designs of the PLC-based software development into a behaviorally-equivalent Verilog program, which is a starting point of a typical FPGA-based hardware development. We expect that the proposed software development process can bridge the gap between two software developing approaches with different platforms, such as PLC and FPGA. This paper also demonstrates its effectiveness using an example of a prototype version of a real-world RPS in Korea

  10. 76 FR 25353 - Hikma Pharmaceuticals PLC; Analysis of Agreement Containing Consent Orders To Aid Public Comment

    2011-05-04

    ... FEDERAL TRADE COMMISSION [File No. 111 0051] Hikma Pharmaceuticals PLC; Analysis of Agreement...-based form. To ensure that the Commission considers an electronic comment, you must file it on the Web-based form at the Web link: https://ftcpublic.commentworks.com/ftc/hikmabaxter . If this Notice appears...

  11. Five Year Retrospective Study of the Financial Situation of Northern Foods Plc., United Kingdom

    Louie DACOSTA

    2016-09-01

    Full Text Available This study was conducted as a retrospective analysis of Northern Foods Plc., once a major player in FTSE 350 Food Sector, to evaluate its financial situation over a five year period. The ex post factor research design was used for this study. Annual reports and databases on Northern Foods Plc., and Associated British Foods Plc., were used to perform a series of ratio analyses. The results revealed that Northern Foods Plc.’s performance has been declining as evidenced in the profitability ratios calculated. Also, financial strength was weak and working capital has not been effectively managed, hence affecting its cash and profit generation potentials. The company was limited in its ability to grow and expand as it needed to regularly fund its pension deficit, and finance its high levels of debt. The study concludes that Northern Foods was not in a very strong financial position, yet it was not making the required investments to improve, hence its takeover though this paper will not rule out non-financial issues. Furthermore, the study prescribed five generic points to improve the financial health of any organisation.

  12. 76 FR 29814 - Statutory Debarment and Reinstatement of BAE Systems plc

    2011-05-23

    ... Bureau of Political-Military Affairs; Statutory Debarment and Reinstatement of BAE Systems plc and Policy... of Defense Trade Controls Compliance, Bureau of Political-Military Affairs, Department of State (202... required. Statutory debarment is based solely upon conviction in a criminal proceeding, conducted by a...

  13. Fuel cycle and waste management: A perspective from British nuclear fuels plc

    Holmes, R.G.G.; Fairhall, G.A.; Robbins, R.A.

    1996-01-01

    The phrase fuel cycle and waste management implies two separate and distinct activities. British Nuclear Fuels plc (BNFL) has adopted a holistic approach to the fuel cycle that integrates the traditional fuel cycle activities of conversion to uranium hexafluoride, fuel fabrication, power generation, and reprocessing with waste arisings, its subsequent treatment, and disposal

  14. What is the method in applying formal methods to PLC applications?

    Mader, Angelika H.; Engel, S.; Wupper, Hanno; Kowalewski, S.; Zaytoon, J.

    2000-01-01

    The question we investigate is how to obtain PLC applications with confidence in their proper functioning. Especially, we are interested in the contribution that formal methods can provide for their development. Our maxim is that the place of a particular formal method in the total picture of system

  15. Dealing with Phrase Level Co-Articulation (PLC) in speech recognition: a first approach

    Ordelman, Roeland J.F.; van Hessen, Adrianus J.; van Leeuwen, David A.; Robinson, Tony; Renals, Steve

    1999-01-01

    Whereas nowadays within-word co-articulation effects are usually sufficiently dealt with in automatic speech recognition, this is not always the case with phrase level co-articulation effects (PLC). This paper describes a first approach in dealing with phrase level co-articulation by applying these

  16. A PLC platform-independent structural analysis on FBD programs for digital reactor protection systems

    Jung, Sejin; Yoo, Junbeom; Lee, Young-Jun

    2017-01-01

    Highlights: • FBD has been widely used to implement safety-critical software for PLC-based systems. • The safety-critical software should be developed strictly with safety programming guidelines. • There are no argued rules that have specific links to higher guidelines NUREG/CR-6463 PLC platform-independently. • This paper proposes a set of rules on the structure of FBD programs with providing specific links to higher guidelines. • This paper also provides CASE tool ‘FBD Checker’ for analyzing the structure of FBD. - Abstract: FBD (function block diagram) has been widely used to implement safety-critical software for PLC (programmable logic controller)-based digital nuclear reactor protection systems. The software should be developed strictly in accordance with safety programming guidelines such as NUREG/CR-6463. Software engineering tools of PLC vendors enable us to present structural analyses using FBD programs, but specific rules pertaining to the guidelines are enclosed within the commercial tools, and specific links to the guidelines are not clearly communicated. This paper proposes a set of rules on the structure of FBD programs in accordance with guidelines, and we develop an automatic analysis tool for FBD programs written in the PLCopen TC6 format. With the proposed tool, any FBD program that is transformed into an open format can be analyzed the PLC platform-independently. We consider a case study on FBD programs obtained from a preliminary version of a Korean nuclear power plant, and we demonstrate the effectiveness and potential of the proposed rules and analysis tool.

  17. Application of PLC to dynamic control system for liquid He cryogenic pumping facility on JT-60U NBI system

    Honda, A.; Okano, F.; Ooshima, K.; Akino, N.; Kikuchi, K.; Tanai, Y.; Takenouchi, T.; Numazawa, S.; Ikeda, Y.

    2008-01-01

    The control system of the cryogenic facility in the JT-60 NBI system has been replaced by employing the PLC (Programmable Logic Controller) and SCADA (Supervisory Control And Data Acquisition) system. The original control system was constructed about 20 years ago by specifying the DCS (Distributed Control System) computer to deal with ∼400 feedback loops. Recently, troubles on this control system have increased due to its age-induced deterioration. To maintain the high reliability of the cryogenic facility, a new control system has been planned with the PLC and SCADA systems. Their attractive features include high market availability and cost-effectiveness, however, the use of PLC for such a large facility with ∼400 feedback loops has not been established because of insufficient processing capability of the early PLC. Meanwhile, the recent progress in the PLC enables to use the FBD (function block diagram) programming language for 500 function blocks. By optimizing the function blocks and connecting them in the FBD language, the feedback loops have been successfully replaced from DCS to PLC without a software developer. Moreover, an oscillation of the liquid He level, which often occurs during the cooldown mode of the cryopumps, can be automatically stabilized by easily adding a new process program in the PLC. At present, the new control system has worked well

  18. A Fractional Lower Order Statistics-Based MIMO Detection Method in Impulse Noise for Power Line Channel

    CHEN, Z.

    2014-11-01

    Full Text Available Impulse noise in power line communication (PLC channel seriously degrades the performance of Multiple-Input Multiple-Output (MIMO system. To remedy this problem, a MIMO detection method based on fractional lower order statistics (FLOS for PLC channel with impulse noise is proposed in this paper. The alpha stable distribution is used to model impulse noise, and FLOS is applied to construct the criteria of MIMO detection. Then the optimal detection solution is obtained by recursive least squares algorithm. Finally, the transmitted signals in PLC MIMO system are restored with the obtained detection matrix. The proposed method does not require channel estimation and has low computational complexity. The simulation results show that the proposed method has a better PLC MIMO detection performance than the existing ones under impulsive noise environment.

  19. Restructuring of SE, Plc - from a functionally managed company to a process managed commercial-production company

    Ravasz, V.

    2004-01-01

    The purpose of this presentation is to inform the participants about present changes currently occurred within Slovenske elektrarne, a. s. (SE, Plc). Changes are related to the liberalisation of the electricity market and expected accession of Slovakia to EU. To support its competitiveness, the SE, Plc became a customer-oriented company, prepared to the access of strategic investor. The paper includes the basic information about centralisation and project of Restructuring of SE, Plc., which has started in December 2003. The aim of Restructuring is the change from functionally managed company to a process managed commercial-production company

  20. A Cost Effective Solution for Development Environment for Data Acquisition, Monitoring and Simulation of PLC Controlled Applications

    O. Bjelica

    2014-06-01

    Full Text Available It is very important to test and monitor the operation of Programmable Logic Controller (PLC in real time (online. Nowadays, conventional, but expensive monitoring systems for PLCs, such as Supervisory Control and Data Acquisition (SCADA systems, software and hardware simulators (or debuggers, are widely used. This paper proposes a user friendly and cost-effective development environment for monitoring, data acquisition and online simulation of applications with PLC. The purpose of this solution is to simulate the process which is controlled by the PLC. The performances of the proposed development environment are presented on the examples of washing machine and dishwasher simulators.

  1. Session 1984-1985. Radioactive waste. Minutes of evidence, Monday 13 May 1985. British Nuclear Fuels plc

    1985-01-01

    The Environment Select Committee of the House of Commons received a memorandum from British Nuclear Fuels plc on the treatment and preparation for disposal of radioactive wastes, under the headings: introduction; waste categories; waste management policy; waste arisings; waste treatment plans; appendix I - British Nuclear Fuels plc; appendix II - the nuclear fuel cycle for Magnox, AGR and LWR reactors; appendix III - control of liquid radioactive discharges from Sellafield and their environmental impact. Representatives of BNF plc were examined on the subject of the memorandum and the minutes of evidence are recorded.

  2. Session 1984-85. Radioactive waste. Minutes of evidence, Monday 13 May 1985. British Nuclear Fuels plc

    1985-01-01

    The Environment Select Committee of the House of Commons received a memorandum from British Nuclear Fuels plc on the treatment and preparation for disposal of radioactive wastes, under the headings: introduction; waste categories; waste management policy; waste arisings; waste treatment plans; appendix I - British Nuclear Fuels plc; appendix II - the nuclear fuel cycle for Magnox, AGR and LWR reactors; appendix III - control of liquid radioactive discharges from Sellafield and their environmental impact. Representatives of BNF plc were examined on the subject of the memorandum and the minutes of evidence are recorded. (U.K.)

  3. Wuestite - a solar energy carrier

    Weidenkaff, A; Nueesch, P; Wokaun, A [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Reller, A [Hamburg Univ., Hamburg (Germany)

    1997-06-01

    Hydrogen is produced when Wuestite (Fe{sub 1-y}O) is oxidised by water. This reaction is part of a two-step thermochemical metal oxide cycle for the storage of solar energy in the form of chemical energy carriers, characterised by a high chemical potential. The reaction was studied in a tubular furnace with on-line gas analysis and further characterised in detail by DTA und high-temperature X-ray powder diffraction. The influence of non-stoichiometry, morphology and temperature on the mechanism and kinetics of the water-splitting reaction was determined. (author) 3 figs., tabs., 3 refs.

  4. Peptide-Carrier Conjugation

    Hansen, Paul Robert

    2015-01-01

    To produce antibodies against synthetic peptides it is necessary to couple them to a protein carrier. This chapter provides a nonspecialist overview of peptide-carrier conjugation. Furthermore, a protocol for coupling cysteine-containing peptides to bovine serum albumin is outlined....

  5. Air Carrier Traffic Statistics.

    2013-11-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  6. Air Carrier Traffic Statistics.

    2012-07-01

    This report contains airline operating statistics for large certificated air carriers based on data reported to U.S. Department of Transportation (DOT) by carriers that hold a certificate issued under Section 401 of the Federal Aviation Act of 1958 a...

  7. Smart Grid Applications for a Practical Implementation of IP over Narrowband Power Line Communications

    Noelia Uribe-Pérez

    2017-11-01

    Full Text Available Currently, Advanced Metering Infrastructure (AMI systems have equipped the low voltage section with a communication system that is being used mainly for metering purposes, but it can be further employed for additional applications related to the Smart Grid (SG concept. This paper explores the potential applications beyond metering of the available channel in a Power Line Communication-based AMI system. To that end, IP has been implemented over Narrow Band-Power Line Communication (NB-PLC in a real microgrid, which includes an AMI system. A thorough review of potential applications for the SG that might be implemented for this representative case is included in order to provide a realistic analysis of the potentiality of NB-PLC beyond smart metering. The results demonstrate that existing AMI systems based on NB-PLC have the capacity to implement additional applications such as remote commands or status signals, which entails an added value for deployed AMI systems.

  8. Development of Application Programming Tool for Safety Grade PLC (POSAFE-Q)

    Koo, Kyungmo; You, Byungyong; Kim, Tae-Wook; Cho, Sengjae; Lee, Jin S.

    2006-01-01

    The pSET (POSAFE-Q Software Engineering Tool) is an application programming tool of the POSAFE-Q which is a safety graded programmable logic controller (PLC) developed for the reactor protect system of the nuclear power plant. The pSET provides an integrated development environment (IDE) which includes editors, compiler, simulator, down loader, debugger, and monitor. The pSET supports the IEC61131-3 standard software model and languages such as LD (ladder diagram) and FBD (function block diagram) which are two of the most widely used PLC programming languages in industry fields. The pSET will also support SFC (sequential function chart) language. The pSET is developed as a part of a Korea Nuclear Instrumentation and Control System (KNICS) project

  9. Saltwell PIC Skid Programmable Logic Controller (PLC) Software Configuration Management Plan

    KOCH, M.R.

    1999-01-01

    This document provides the procedures and guidelines necessary for computer software configuration management activities during the operation and maintenance phases of the Saltwell PIC Skids as required by LMH-PRO-309/Rev. 0, Computer Software Quality Assurance, Section 2.6, Software Configuration Management. The software configuration management plan (SCMP) integrates technical and administrative controls to establish and maintain technical consistency among requirements, physical configuration, and documentation for the Saltwell PIC Skid Programmable Logic Controller (PLC) software during the Hanford application, operations and maintenance. This SCMP establishes the Saltwell PIC Skid PLC Software Baseline, status changes to that baseline, and ensures that software meets design and operational requirements and is tested in accordance with their design basis

  10. Evaluation of a fast PLC module in prospect of the LHC beam interlock system

    Zaera-Sanz, Manuel

    2005-01-01

    The LHC Beam Interlock system requires a controller performing a simple matrix function to collect the different beam dump requests. To satisfy the expected safety level of the Interlock, the system should be robust and reliable. The PLC is a promising candidate to fulfil both aspects but too slow to meet the expected response time which is of the order of mseconds. Siemens has introduced a “so called” fast module (FM352-5 Boolean Processor) that provides independent and extremely fast control of a process within a larger control system using an onboard processor, a Field Programmable Gate Array (FPGA), to execute code in parallel which results in extremely fast scan times. It is interesting to investigate its features and to evaluate it as a possible candidate for the beam interlock system. This note publishes the results of this study. As well, this note could be useful for other applications requiring fast processing using a PLC.

  11. Integrated software environment dedicated for implementation of control systems based on PLC controllers

    Szymon SURMA

    2007-01-01

    Full Text Available Industrial processes’ control systems based on PLC controllers play today a very important role in all fields of transport, including also sea transport. Construction of control systems is the field of engineering, which has been continuously evolving towards maximum simplification of system design path. Up to now the time needed forthe system construction from the design to commissioning had to be divided into a few stages. A mistake made in an earlier stage caused that in most cases the next stages had to be restarted. Available debugging systems allows defect detection at an early stage of theproject implementation. The paper presents general characteristic of integrated software for implementation of complex control systems. The issues related to the software use for programming of the visualisation environment, control computer, selection oftransmission medium and transmission protocol as well as PLC controllers’ configuration, software and control have been analysed.

  12. Design of monitoring system for mail-sorting based on the Profibus S7 series PLC

    Zhang, W.; Jia, S. H.; Wang, Y. H.; Liu, H.; Tang, G. C.

    2017-01-01

    With the rapid development of the postal express, the workload of mail sorting is increasing, but the automatic technology of mail sorting is not mature enough. In view of this, the system uses Siemens S7-300 PLC as the main station controller, PLC of Siemens S7-200/400 is from the station controller, through the man-machine interface configuration software MCGS, PROFIBUS-DP communication, RFID technology and mechanical sorting hand achieve mail classification sorting monitoring. Among them, distinguish mail-sorting by scanning RFID posted in the mail electronic bar code (fixed code), the system uses the corresponding controller on the acquisition of information processing, the processed information transmit to the sorting manipulator by PROFIBUS-DP. The system can realize accurate and efficient mail sorting, which will promote the development of mail sorting technology.

  13. Design and control of multifunctional sorting and training platform based on PLC control

    Wan, Hongqiang; Ge, Shuai; Han, Peiying; Li, Fancong; Zhang, Simiao

    2018-05-01

    Electromechanical integration, as a multi-disciplinary subject, has been paid much attention by universities and is widely used in the automation production of enterprises. Aiming at the problem of the lack of control among enterprises and the lack of training among colleges and universities, this paper presents a design of multifunctional sorting training platform based on PLC control. Firstly, the structure of the platform is determined and three-dimensional modeling is done. Then design the platform's aerodynamic control and electrical control. Finally, realize the platform sorting function through PLC programming and configuration software development. The training platform can be used to design the practical training experiment, which has a strong advance and pertinence in the electromechanical integration teaching. At the same time, the platform makes full use of modular thinking to make the sorting modules more flexible. Compared with the traditional training platform, its teaching effect is more significant.

  14. Comparative analysis of different configurations of PLC-based safety systems from reliability point of view

    Tapia, Moiez A.

    1993-01-01

    The study of a comparative analysis of distinct multiplex and fault-tolerant configurations for a PLC-based safety system from a reliability point of view is presented. It considers simplex, duplex and fault-tolerant triple redundancy configurations. The standby unit in case of a duplex configuration has a failure rate which is k times the failure rate of the standby unit, the value of k varying from 0 to 1. For distinct values of MTTR and MTTF of the main unit, MTBF and availability for these configurations are calculated. The effect of duplexing only the PLC module or only the sensors and the actuators module, on the MTBF of the configuration, is also presented. The results are summarized and merits and demerits of various configurations under distinct environments are discussed.

  15. Evaluation and application of a fast module in a PLC based interlock and control system

    Zaera-Sanz, M

    2009-01-01

    The LHC Beam Interlock system requires a controller performing a simple matrix function to collect the different beam dump requests. To satisfy the expected safety level of the Interlock, the system should be robust and reliable. The PLC is a promising candidate to fulfil both aspects but too slow to meet the expected response time which is of the order of μseconds. Siemens has introduced a 'so called' fast module (FM352-5 Boolean Processor). It provides independent and extremely fast control of a process within a larger control system using an onboard processor, a Field Programmable Gate Array (FPGA), to execute code in parallel which results in extremely fast scan times. It is interesting to investigate its features and to evaluate it as a possible candidate for the beam interlock system. This paper publishes the results of this study. As well, this paper could be useful for other applications requiring fast processing using a PLC.

  16. Amarogentin, a secoiridoid glycoside, abrogates platelet activation through PLC γ 2-PKC and MAPK pathways.

    Yen, Ting-Lin; Lu, Wan-Jung; Lien, Li-Ming; Thomas, Philip Aloysius; Lee, Tzu-Yin; Chiu, Hou-Chang; Sheu, Joen-Rong; Lin, Kuan-Hung

    2014-01-01

    Amarogentin, an active principle of Gentiana lutea, possess antitumorigenic, antidiabetic, and antioxidative properties. Activation of platelets is associated with intravascular thrombosis and cardiovascular diseases. The present study examined the effects of amarogentin on platelet activation. Amarogentin treatment (15~60  μM) inhibited platelet aggregation induced by collagen, but not thrombin, arachidonic acid, and U46619. Amarogentin inhibited collagen-induced phosphorylation of phospholipase C (PLC) γ2, protein kinase C (PKC), and mitogen-activated protein kinases (MAPKs). It also inhibits in vivo thrombus formation in mice. In addition, neither the guanylate cyclase inhibitor ODQ nor the adenylate cyclase inhibitor SQ22536 affected the amarogentin-mediated inhibition of platelet aggregation, which suggests that amarogentin does not regulate the levels of cyclic AMP and cyclic GMP. In conclusion, amarogentin prevents platelet activation through the inhibition of PLC γ2-PKC cascade and MAPK pathway. Our findings suggest that amarogentin may offer therapeutic potential for preventing or treating thromboembolic disorders.

  17. Saltwell Leak Detector Station Programmable Logic Controller (PLC) Software Configuration Management Plan (SCMP)

    WHITE, K.A.

    2000-01-01

    This document provides the procedures and guidelines necessary for computer software configuration management activities during the operation and maintenance phases of the Saltwell Leak Detector Stations as required by HNF-PRO-309/Rev.1, Computer Software Quality Assurance, Section 2.4, Software Configuration Management. The software configuration management plan (SCMP) integrates technical and administrative controls to establish and maintain technical consistency among requirements, physical configuration, and documentation for the Saltwell Leak Detector Station Programmable Logic Controller (PLC) software during the Hanford application, operations and maintenance. This SCMP establishes the Saltwell Leak Detector Station PLC Software Baseline, status changes to that baseline, and ensures that software meets design and operational requirements and is tested in accordance with their design basis

  18. Developing a Novel USB-PLC Controller for a Mechatronics Cloud Laboratory

    Wen-Jye Shyr

    2013-04-01

    Full Text Available This study proposes the development and implementation of a novel Universal Serial Bus (USB-Programmable Logic Controller (PLC, called a USB-PLC controller, for a mechatronics cloud laboratory. The aim of a mechatronics cloud laboratory is to provide state of the art research quality equipment to students, allowing them to conduct hands-on experiments via the Internet. One objective of the cloud laboratory is to not only provide equipment for conducting set experiments, but also to provide a means for students to access research equipment in order to conduct individual research experiments. The proposed controller for these cloud laboratory experiments has been chosen in order to expose the students to as many different engineering and technology disciplines as possible.

  19. PLC based automatic control of pasteurize mix in ice cream production

    Yao, Xudong; Liang, Kai

    2013-03-01

    This paper describes the automatic control device of pasteurized mix in the ice cream production process.We design a scheme of control system using FBD program language and develop the programmer in the STEP 7-Micro/WIN software, check for any bugs before downloading into PLC .These developed devices will able to provide flexibility and accuracy to control the step of pasteurized mix. The operator just Input the duration and temperature of pasteurized mix through control panel. All the steps will finish automatically without any intervention in a preprogrammed sequence stored in programmable logic controller (PLC). With the help of this equipment we not only can control the quality of ice cream for various conditions, but also can simplify the production process. This control system is inexpensive and can be widely used in ice cream production industry.

  20. Development of Remote Monitoring and a Control System Based on PLC and WebAccess for Learning Mechatronics

    Wen-Jye Shyr; Te-Jen Su; Chia-Ming Lin

    2013-01-01

    This study develops a novel method for learning mechatronics using remote monitoring and control, based on a programmable logic controller (PLC) and WebAccess. A mechatronics module, a Web‐CAM and a PLC were integrated with WebAccess software to organize a remote laboratory. The proposed system enables users to access the Internet for remote monitoring and control of the mechatronics module via a web browser, thereby enhancing work flexibility by enabling personnel to control mechatronics equ...

  1. Power Line Communications for Smart Grid Applications

    Lars Torsten Berger

    2013-01-01

    Full Text Available Power line communication, that is, using the electricity infrastructure for data transmission, is experiencing a renaissance in the context of Smart Grid. Smart Grid objectives include the integration of intermittent renewable energy sources into the electricity supply chain, securing reliable electricity delivery, and using the existing electrical infrastructure more efficiently. This paper surveys power line communications (PLCs in the context of Smart Grid. The specifications G3-PLC, PRIME, HomePlug Green PHY, and HomePlug AV2, and the standards IEEE 1901/1901.2 and ITU-T G.hn/G.hnem are discussed.

  2. Effective time management for high performance in an organization Case: Lasaco Assurance PLC

    Adeojo, Adeyinka

    2012-01-01

    The main objective of this thesis is to determine the effect of time management on high organizational performance using LASACO ASSURANCE Plc. as a case company. In this thesis, the employees working with the company were sent questionnaires. Their responses were critically analyzed and thus related to the theories. A quantitative approach was used as the methodology. According to the theory, time management is a method for managers to increase work performance effectiveness. Time man...

  3. 78 FR 54152 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-09-03

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT...; -535C-37; -535E4-37; - 535E4-B-37, and -535E4-B-75 turbofan engines, and all RB211-524G2-19; - 524G3-19; -524H2-19; and -524H-36 turbofan engines. This AD requires a one-time inspection of the front combustion...

  4. 78 FR 61168 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-10-03

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... (RR) RB211-535E4-37, RB211-535E4-B-37, RB211-535E4-C- 37, and RB211-535E4-B-75 turbofan engines. This...-37, RB211-535E4-B-37, RB211-535E4-C-37, and RB211-535E4-B-75 turbofan engines. (d) Unsafe Condition...

  5. 78 FR 60658 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    2013-10-02

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT..., 892-17, 892B-17, and 895-17; and RB211-524G2-T-19, -524G3-T- 19, -524H-T-36, and -524H2-T-19 turbofan... (RR) model turbofan engines that have a high-pressure (HP) compressor stage 1 to 4 rotor disc...

  6. Based on the Hardware Resources Configurable Shanke PLC Building Energy Consumption Detection System

    Cheng Guanghe

    2017-01-01

    Full Text Available According to the actual situation of the comprehensive office building and the functional requirements of the building energy consumption monitoring and management system, the office building energy consumption monitoring and management system is designed by using the hardware resource configurable Shanke PLC(SKPLC as the data collector. The system uses data bus technology and field data acquisition technology to achieve the building energy consumption data acquisition and management. Practice has proved that energy-saving effect is good.

  7. 160 Gb/s OFDM transmission utilizing an all-optical symbol generator based on PLC

    Liang, Xiaojun; Qiao, Yaojun; Li, Wei; Mei, Junyao; Qin, Yi

    2009-11-01

    We demonstrate a 160 Gb/s orthogonal frequency division multiplexing (OFDM) system using an all-optical symbol generator based on planar light circuit (PLC) technology. Excellent bit error rate (BER) is observed after long-distance transmission. The proposed symbol generator fundamentally eliminates the processing speed limits introduced by electronics and is suitable for high integration, making it physically realizable to build high-speed all-optical OFDM systems with a large number of subcarriers.

  8. Increase in Multicast OFDM Data Rate in PLC Network using Adaptive LP-OFDM

    Maiga , Ali; Baudais , Jean-Yves; Hélard , Jean-François

    2009-01-01

    ISBN: 978-1-4244-3523-4; International audience; Linear precoding (LP) technique applied to OFDM systems has already proved its ability to significantly increase the system throughput in a powerline communication (PLC) context. In this paper, we propose resource allocation algorithms based on the LP technique to increase the multicast OFDM systems bit rate. The conventional multicast capacity is limited by the user which experiences the worst channel conditions. To increase the multicast bit ...

  9. Capital Discipline and Financial Market Relations in Retail Globalization: Insights from the Case of Tesco plc

    Wood, Steven; Wrigley, N; Coe, NM

    2016-01-01

    This paper provides an in-depth study of leading transnational food retailer Tesco plc to explore how its financial management and relations with the investment community – notably its reputation for capital discipline – underpinned successful expansion. Informed by close dialogue with equity analysts, we investigate how this model deteriorated since the late 2000s with declining returns, leading to high-profile international divestitures. The analysis assesses the drivers of these difficulti...

  10. Business strategy and the environment Tesco Plc's declining financial performance and underlying issues

    Haddock-Millar, Julie; Rigby, Chris

    2015-01-01

    The case presents a teaching tool which requires students to: 1) analyze the financial performance of Tesco Plc over the last four years; 2) compare Tesco’s market position with key competitors; 3) identify and evaluate Tesco’s business strategy; 4) evaluate the causes of Tesco’s decline in performance; 5) develop recommendations to address declining performance; 6) identify and evaluate the Human Resource strategic role in addressing and supporting performance. The case is suitable for a bus...

  11. Turnaround and Sustainability in Economic Crisis: The Case of NEXT PLC

    Zhang, Biyan

    2013-01-01

    Purpose- against a background of continued weak economic conditions and with many firms experiencing declining financial performance, this paper presents a synthesis of the business turnaround literature and combines with analysis case –NEXT plc. It purposes to discus the turnaround strategies can keep the declining firm sustainability recovery, during the economic cycle. \\ud \\ud Design/methodology/approach- the turnaround strategy for sustainability recovery are examined by a case study of N...

  12. On Verification of PLC-Programs Written in the LD-Language

    E. V. Kuzmin

    2012-01-01

    Full Text Available We discuss some questions connected with the construction of a technology of analysing correctness of Programmable Logic Controller programs. We consider an example of modeling and automated verification of PLC-programs written in the Ladder Diagram language (including timed function blocks of the IEC 61131-3 standard. We use the Cadence SMV for symbolic model checking. Program properties are written in the linear-time temporal logic LTL.

  13. PEMBUATAN SISTEM KONTROL MESIN CAULKING ROD GUIDE OTOMATIS MENGGUNAKAN PLC OMRON CPM1A

    Syahril Ardi

    2015-02-01

    Full Text Available Kenaikan tingkat produksi shock absorber perusahaan manufaktur membuat proses produksi harus berjalan dengan baik . Pipa proses pemotongan pada mendempul panduan mesin batang memiliki beberapa masalah yang harus diatasi . Untuk mengatasi masalah tersebut kemudian melakukan modifikasi mesin batang mendempul yang secara otomatis dapat mengurangi waktu siklus pada proses mendempul batang dari 4,5 detik per potong sehingga tingkat produksi memotong garis pipa dapat ditingkatkan . Sistem kontrol otomatis mendempul mesin batang panduan ini dirancang untuk menggunakan Programmable Logic Controller (PLC

  14. Drosophila fatty acid taste signals through the PLC pathway in sugar-sensing neurons.

    Pavel Masek

    Full Text Available Taste is the primary sensory system for detecting food quality and palatability. Drosophila detects five distinct taste modalities that include sweet, bitter, salt, water, and the taste of carbonation. Of these, sweet-sensing neurons appear to have utility for the detection of nutritionally rich food while bitter-sensing neurons signal toxicity and confer repulsion. Growing evidence in mammals suggests that taste for fatty acids (FAs signals the presence of dietary lipids and promotes feeding. While flies appear to be attracted to fatty acids, the neural basis for fatty acid detection and attraction are unclear. Here, we demonstrate that a range of FAs are detected by the fly gustatory system and elicit a robust feeding response. Flies lacking olfactory organs respond robustly to FAs, confirming that FA attraction is mediated through the gustatory system. Furthermore, flies detect FAs independent of pH, suggesting the molecular basis for FA taste is not due to acidity. We show that low and medium concentrations of FAs serve as an appetitive signal and they are detected exclusively through the same subset of neurons that sense appetitive sweet substances, including most sugars. In mammals, taste perception of sweet and bitter substances is dependent on phospholipase C (PLC signaling in specialized taste buds. We find that flies mutant for norpA, a Drosophila ortholog of PLC, fail to respond to FAs. Intriguingly, norpA mutants respond normally to other tastants, including sucrose and yeast. The defect of norpA mutants can be rescued by selectively restoring norpA expression in sweet-sensing neurons, corroborating that FAs signal through sweet-sensing neurons, and suggesting PLC signaling in the gustatory system is specifically involved in FA taste. Taken together, these findings reveal that PLC function in Drosophila sweet-sensing neurons is a conserved molecular signaling pathway that confers attraction to fatty acids.

  15. Research on energy efficiency design index for sea-going LNG carriers

    Lin, Yan; Yu, Yanyun; Guan, Guan

    2014-12-01

    This paper describes the characteristics of liquefied natural gas (LNG) carriers briefly. The LNG carrier includes power plant selection, vapor treatment, liquid cargo tank type, etc. Two parameters—fuel substitution rate and recovery of boil of gas (BOG) volume to energy efficiency design index (EEDI) formula are added, and EEDI formula of LNG carriers is established based on ship EEDI formula. Then, based on steam turbine propulsion device of LNG carriers, mathematical models of LNG carriers' reference line value are established in this paper. By verification, the EEDI formula of LNG carriers described in this paper can provide a reference for LNG carrier EEDI calculation and green shipbuilding.

  16. PLC based development of control, monitoring and interlock for 100 kW, 45.6 MHz ICRH system

    Jadav, Hiralal; Joshi, Rameshkumar; Mali, Aniruddh K.; Kadia; Bhavesh; Parmar; Maganbhai, Kiritkumar; Kulkarni, S.V.

    2015-01-01

    This paper presents details of PLC based system development for 100KW at the rate 45.6 MHz. Presently in ICRH RF DAC (Data acquisition and control) system existing based on real time VME and linux operating system. The ICRH system consists of 1.5 MW RF generator operating at 22- 40MHz which is used for second harmonic heating and pre-ionization experiments on SST-1 Tokamak at 1.5T and 3T magnetic field operation respectively. The task of PLC system in RF ICRH is to control, monitoring and interlocks HVDC power supply signal. Voltage and current signal of 2 kW, 20 kW, tetrode for 100 kW RF tube electrode like Filament, Control grid, Plate, Screen grid, signal monitor and voltage set raised by PLC analog IO module. Acknowledgement of the HVDC supply Filament, Control grid, Plate, Screen grid power supply is monitor and interlocks by PLC Digital IO module to interlocks stop the RF pulse and off HV power supply. The RF pulse(shot) to trigger signal generator (5mw) RF power output feed to LPA then chain of 2 KW, 20 KW, 100 KW at the rate 45.6 MHz. The programming logic controller (PLC) software is written in ladder language for AH500 Delta make using ISP Soft 2.04 and GUI is in the table form to control and monitor the parameters. Communication of PLC to PC by ethernet LAN network. (author)

  17. The effect of a dynamic PCL brace on patellofemoral compartment pressures in PCL-and PCL/PLC-deficient knees.

    Welch, Tyler; Keller, Thomas; Maldonado, Ruben; Metzger, Melodie; Mohr, Karen; Kvitne, Ronald

    2017-12-01

    The natural history of posterior cruciate ligament (PCL) deficiency includes the development of arthrosis in the patellofemoral joint (PFJ). The purpose of this biomechanical study was to evaluate the hypothesis that dynamic bracing reduces PFJ pressures in PCL- and combined PCL/posterolateral corner (PLC)-deficient knees. Controlled Laboratory Study. Eight fresh frozen cadaveric knees with intact cruciate and collateral ligaments were included. PFJ pressures and force were measured using a pressure mapping system via a lateral arthrotomy at knee flexion angles of 30°, 60°, 90°, and 120° in intact, PCL-deficient, and PCL/PLC-deficient knees under a combined quadriceps/hamstrings load of 400 N/200 N. Testing was then repeated in PCL- and PCL/PLC-deficient knees after application of a dynamic PCL brace. Application of a dynamic PCL brace led to a reduction in peak PFJ pressures in PCL-deficient knees. In addition, the brace led to a significant reduction in peak pressures in PCL/PLC-deficient knees at 60°, 90°, and 120° of flexion. Application of the dynamic brace also led to a reduction in total PFJ force across all flexion angles for both PCL- and PCL/PLC-deficient knees. Dynamic bracing reduces PFJ pressures in PCL- and combined PCL/PLC-deficient knees, particularly at high degrees of knee flexion.

  18. Evaluation of PLC Channel Capacity and ABER Performances for OFDM-Based Two-Hop Relaying Transmission

    Sana Ezzine

    2017-01-01

    Full Text Available Powerline network is recognized as a favorable infrastructure for Smart Grid to transmit information in the network thanks to its broad coverage and low cost deployment. The existing works are trying to improve and adapt transmission techniques to reduce Powerline Communication (PLC channel attenuation and exploit the limited bandwidth to support high data rate over long distances. Two-hop relaying BroadBand PLC (BB-PLC system, in which Orthogonal Frequency Division Multiplexing (OFDM is used, is considered in this paper. We derive and compare the PLC channel capacity and the end-to-end Average BER (ABER for OFDM-based direct link (DL BB-PLC system and for OFDM-based two-hop relaying BB-PLC system for Amplify and Forward (AF and Decode and Forward (DF protocols. We analyze the improvements when we consider the direct link in a cooperative communication when the relay node only transmits the correctly decoded signal. Maximum ratio combining is employed at the destination node to detect the transmitted signal. In addition, in this paper, we highlight the impact of the relay location on the channel capacity and ABER for AF and DF transmission protocols. Moreover, an efficient use of the direct link was also investigated in this paper.

  19. On an LAS-integrated soft PLC system based on WorldFIP fieldbus.

    Liang, Geng; Li, Zhijun; Li, Wen; Bai, Yan

    2012-01-01

    Communication efficiency is lowered and real-time performance is not good enough in discrete control based on traditional WorldFIP field intelligent nodes in case that the scale of control in field is large. A soft PLC system based on WorldFIP fieldbus was designed and implemented. Link Activity Scheduler (LAS) was integrated into the system and field intelligent I/O modules acted as networked basic nodes. Discrete control logic was implemented with the LAS-integrated soft PLC system. The proposed system was composed of configuration and supervisory sub-systems and running sub-systems. The configuration and supervisory sub-system was implemented with a personal computer or an industrial personal computer; running subsystems were designed and implemented based on embedded hardware and software systems. Communication and schedule in the running subsystem was implemented with an embedded sub-module; discrete control and system self-diagnosis were implemented with another embedded sub-module. Structure of the proposed system was presented. Methodology for the design of the sub-systems was expounded. Experiments were carried out to evaluate the performance of the proposed system both in discrete and process control by investigating the effect of network data transmission delay induced by the soft PLC in WorldFIP network and CPU workload on resulting control performances. The experimental observations indicated that the proposed system is practically applicable. Copyright © 2011 ISA. Published by Elsevier Ltd. All rights reserved.

  20. Modeling of Hydration, Compressive Strength, and Carbonation of Portland-Limestone Cement (PLC Concrete

    Xiao-Yong Wang

    2017-01-01

    Full Text Available Limestone is widely used in the construction industry to produce Portland limestone cement (PLC concrete. Systematic evaluations of hydration kinetics, compressive strength development, and carbonation resistance are crucial for the rational use of limestone. This study presents a hydration-based model for evaluating the influences of limestone on the strength and carbonation of concrete. First, the hydration model analyzes the dilution effect and the nucleation effect of limestone during the hydration of cement. The degree of cement hydration is calculated by considering concrete mixing proportions, binder properties, and curing conditions. Second, by using the gel–space ratio, the compressive strength of PLC concrete is evaluated. The interactions among water-to-binder ratio, limestone replacement ratio, and strength development are highlighted. Third, the carbonate material contents and porosity are calculated from the hydration model and are used as input parameters for the carbonation model. By considering concrete microstructures and environmental conditions, the carbon dioxide diffusivity and carbonation depth of PLC concrete are evaluated. The proposed model has been determined to be valid for concrete with various water-to-binder ratios, limestone contents, and curing periods.

  1. Praksisnær skoleudvikling og PLC som strategisk udviklingsaktør

    Christensen, Ole; Bach, Anna

    2017-01-01

    I det følgende belyses, hvorledes PLC kan udvikles som strategisk udviklingsaktør og understøtte praksisnær skoleudvikling. Vi ønsker at belyse hvorledes Bekendtgørelsens overordnede intentioner kan få retning og rammer og dermed medvirke til, at hele det pædagogiske personale indgår i skoleudvik......I det følgende belyses, hvorledes PLC kan udvikles som strategisk udviklingsaktør og understøtte praksisnær skoleudvikling. Vi ønsker at belyse hvorledes Bekendtgørelsens overordnede intentioner kan få retning og rammer og dermed medvirke til, at hele det pædagogiske personale indgår i...... skoleudviklingen. I den forbindelse er det vores erfaring, at PLC kan spille en central rolle i forbindelse med den praksisnære og lokale skoleudvikling. Erfaringerne bygger især på udviklings- og forskningsprojekter fra kommunerne Kolding, København, Roskilde og Tårnby. Der har været tale om praksisnære...

  2. A Simulator of Periodically Switching Channels for Power Line Communications

    Hayasaki, Taro; Umehara, Daisuke; Denno, Satoshi; Morikura, Masahiro

    An indoor power line is one of the most attractive media for in-home networks. However, there are many technical problems for achieving in-home power line communication (PLC) with high rate and high reliability. One of such problem is the degradation in the performance of the in-home PLC caused by periodically time-varying channel responses, particularly when connecting the switching power supply equipment. We present a measurement method for power line channel responses and reveal the switching of the channel responses synchronized with power-frequency voltage when connecting switching power supply equipment in sending or receiving outlets. In this paper, we term them periodically switching channel responses. The performance of PLC adapters is seriously affected by the periodically switching channel responses. Therefore, we provide a modeling of the periodically switching channel responses by using finite impulse response (FIR) filters with a shared channel memory and construct a simulator for in-home power line channels including the periodically switching channel responses in order to evaluate the various communication systems through the power line. We present the validity of the proposed simulator through the performance evaluation of OFDM/64QAM over periodically switching channels with additive white Gaussian noise. Furthermore, we evaluate the influence of the periodically switching channel responses on the communication quality of a time-invariant modulation scheme by using the proposed simulator.

  3. Molecular characterization of severin from Clonorchis sinensis excretory/secretory products and its potential anti-apoptotic role in hepatocarcinoma PLC cells.

    Xueqing Chen

    Full Text Available BACKGROUND: Clonorchiasis, caused by the infection of Clonorchis sinensis (C. sinensis, is a kind of neglected tropical disease, but it is highly related to cholangiocarcinoma and hepatocellular carcinoma (HCC. It has been well known that the excretory/secretory products of C. sinensis (CsESPs play key roles in clonorchiasis associated carcinoma. From genome and transcriptome of C. sinensis, we identified one component of CsESPs, severin (Csseverin, which had three putative gelsolin domains. Its homologues are supposed to play a vital role in apoptosis resistance of tumour cell. METHODOLOGY/PRINCIPAL FINDINGS: There was significant similarity in tertiary structures between human gelsolin and Csseverin by bioinformatics analysis. We identified that Csseverin expressed at life stage of adult worm, metacercaria and egg by the method of quantitative real-time PCR and western blotting. Csseverin distributed in vitellarium and intrauterine eggs of adult worm and tegument of metacercaria by immunofluorence assay. We obtained recombinant Csseverin (rCsseverin and confirmed that rCsseverin could bind with calciumion in circular dichroism spectrum analysis. It was demonstrated that rCsseverin was of the capability of actin binding by gel overlay assay and immunocytochemistry. Both Annexin V/PI assay and mitochondrial membrane potential assay of human hepatocarcinoma cell line PLC showed apoptosis resistance after incubation with different concentrations of rCsseverin. Morphological analysis, apoptosis-associated changes of mitochondrial membrane potential and Annexin V/PI apoptosis assay showed that co-incubation of PLC cells with rCsseverin in vitro led to an inhibition of apoptosis induced by serum-starved for 24 h. CONCLUSIONS/SIGNIFICANCE: Collectively, the molecular properties of Csseverin, a molecule of CsESPs, were characterized in our study. rCsseverin could cause obvious apoptotic inhibition in human HCC cell line. Csseverin might exacerbate the

  4. Molecular Characterization of Severin from Clonorchis sinensis Excretory/Secretory Products and Its Potential Anti-apoptotic Role in Hepatocarcinoma PLC Cells

    He, Lei; Wang, Xiaoyun; Liang, Pei; Chen, Wenjun; Bian, Meng; Ren, Mengyu; Lin, Jinsi; Liang, Chi; Xu, Jin; Wu, Zhongdao; Li, Xuerong; Huang, Yan; Yu, Xinbing

    2013-01-01

    Background Clonorchiasis, caused by the infection of Clonorchis sinensis (C. sinensis), is a kind of neglected tropical disease, but it is highly related to cholangiocarcinoma and hepatocellular carcinoma (HCC). It has been well known that the excretory/secretory products of C. sinensis (CsESPs) play key roles in clonorchiasis associated carcinoma. From genome and transcriptome of C. sinensis, we identified one component of CsESPs, severin (Csseverin), which had three putative gelsolin domains. Its homologues are supposed to play a vital role in apoptosis resistance of tumour cell. Methodology/Principal Findings There was significant similarity in tertiary structures between human gelsolin and Csseverin by bioinformatics analysis. We identified that Csseverin expressed at life stage of adult worm, metacercaria and egg by the method of quantitative real-time PCR and western blotting. Csseverin distributed in vitellarium and intrauterine eggs of adult worm and tegument of metacercaria by immunofluorence assay. We obtained recombinant Csseverin (rCsseverin) and confirmed that rCsseverin could bind with calciumion in circular dichroism spectrum analysis. It was demonstrated that rCsseverin was of the capability of actin binding by gel overlay assay and immunocytochemistry. Both Annexin V/PI assay and mitochondrial membrane potential assay of human hepatocarcinoma cell line PLC showed apoptosis resistance after incubation with different concentrations of rCsseverin. Morphological analysis, apoptosis-associated changes of mitochondrial membrane potential and Annexin V/PI apoptosis assay showed that co-incubation of PLC cells with rCsseverin in vitro led to an inhibition of apoptosis induced by serum-starved for 24 h. Conclusions/Significance Collectively, the molecular properties of Csseverin, a molecule of CsESPs, were characterized in our study. rCsseverin could cause obvious apoptotic inhibition in human HCC cell line. Csseverin might exacerbate the process of HCC

  5. Broadband PLC for Clustered Advanced Metering Infrastructure (AMI Architecture

    Augustine Ikpehai

    2016-07-01

    Full Text Available Advanced metering infrastructure (AMI subsystems monitor and control energy distribution through exchange of information between smart meters and utility networks. A key challenge is how to select a cost-effective communication system without compromising the performance of the applications. Current communication technologies were developed for conventional data networks with different requirements. It is therefore necessary to investigate how much of existing communication technologies can be retrofitted into the new energy infrastructure to cost-effectively deliver acceptable level of service. This paper investigates broadband power line communications (BPLC as a backhaul solution in AMI. By applying the disparate traffic characteristics of selected AMI applications, the network performance is evaluated. This study also examines the communication network response to changes in application configurations in terms of packet sizes. In each case, the network is stress-tested and performance is assessed against acceptable thresholds documented in the literature. Results show that, like every other communication technology, BPLC has certain limitations; however, with some modifications in the network topology, it indeed can fulfill most AMI traffic requirements for flexible and time-bounded applications. These opportunities, if tapped, can significantly improve fiscal and operational efficiencies in AMI services. Simulation results also reveal that BPLC as a backhaul can support flat and clustered AMI structures with cluster size ranging from 1 to 150 smart meters.

  6. Prospective radiological dose assessment. Amersham plc (Amersham site) variation application December 1998

    Allott, R.

    2001-01-01

    Amersham plc (previously Nycomed-Amersham plc) submitted an application to the Environment Agency in December 1998 for a variation to their radioactive waste discharge authorisations granted under the Radioactive Substances Act 1993. The application requested a reduction in the discharge limits for certain radionuclides and no change for the remaining radionuclides. Amersham plc undertook a further review of their discharge requirements and submitted a new assessment for revised limits in January 2001. This report provides an assessment of the radiological implications of discharges at these revised limits requested by Amersham plc and the limits proposed by the Agency. It has been prepared by the National Compliance Assessment Service at the request of Thames Region to support their determination of the application. Four candidate critical groups were identified who could be exposed to discharges from the Amersham site: 1) Sewage workers at the Maple Lodge sewage works who might be exposed to external radiation from discharges contained within sewage and inadvertently inhale or ingest sewage. 2) Anglers on the Grand Union Canal who eat a small proportion of their annual catch of freshwater fish, who drink water abstracted solely from the River Colne and eat vegetables irrigated by water from the canal. 3) Persons living closest to site who eat locally produced food. 4) Dog walkers living near to site who eat locally produced food. For continuous discharges at the Agency's proposed annual limits, the highest dose of 160 μSv/y is predicted to be received by infants who live closest to the site and eat locally produced food. Therefore, this has been identified as the critical group. Children and adults living at the same location and eating locally produced food receive doses of 140 μSv/y and 130 μSv/y respectively. The critical group dose is less than the source constraint of 300 μSv/y. The dose is dominated by direct radiation from the site (110 μSv/y) and the

  7. 70Z/3 Cbl induces PLC gamma 1 activation in T lymphocytes via an alternate Lat- and Slp-76-independent signaling mechanism.

    Graham, Laurie J; Verí, Maria-Concetta; DeBell, Karen E; Noviello, Cristiana; Rawat, Rashmi; Jen, Sandy; Bonvini, Ezio; Rellahan, Barbara

    2003-04-24

    The oncoprotein 70Z/3 Cbl signals in an autonomous fashion or through blockade of endogenous c-Cbl, a negative regulator of signaling. The mechanism of 70Z/3 Cbl-induced signaling was investigated by comparing the molecular requirements for 70Z/3 Cbl- and TCR-induced phospholipase C gamma 1 (PLC gamma 1) activation. 70Z/3 Cbl-induced PLC gamma 1 tyrosine phosphorylation required, in addition to the PLC gamma 1 N-terminal SH2 domain, the C-terminal SH2 and SH3 domains that were dispensable for TCR-induced phosphorylation. Deletion of the leucine zipper of 70Z/3 Cbl did not eliminate 70Z/3 Cbl-induced PLC gamma 1 phosphorylation, suggesting that blockage of c-Cbl via dimerization with 70Z/3 Cbl cannot fully explain 70Z/3 Cbl activating characteristics. The complete elimination of PLC gamma 1 phosphorylation required deleting the SH3 domain-binding region of 70Z/3 Cbl, consistent with 70Z/3 Cbl binding the PLC gamma 1 SH3 domain. 70Z/3 Cbl-induced PLC gamma 1 phosphorylation required Zap-70, as for the TCR, and the tyrosine kinase binding domain of 70Z/3 Cbl, which binds Zap-70, but did not require PLC gamma 1 binding to Lat, a crucial interaction in TCR-induced PLC gamma 1 phosphorylation. Furthermore, 70Z/3 Cbl-induced activation of NFAT, a PLC gamma 1/Ca(2+)-dependent transcriptional event, required Zap-70, but was independent of Slp-76, an adapter required for TCR-induced NFAT activation. These results suggest that 70Z/3 Cbl and PLC gamma 1 form a TCR-, Lat- and Slp-76-independent complex that leads to PLC gamma 1 phosphorylation and activation.

  8. High-speed narrowband PLC - High-performance Access Powerline Communication structures in smart grid; High-Speed Narrowband PLC. Leistungsfaehige Access-Powerline-Kommunikationsstrukturen im Smart Grid

    Offner, Georg [devolo AG, Aachen (Germany)

    2012-07-01

    The smart grid provides a stable operation of a decentralized power system which is fed more and more by small providers by means of solar technology and wind power technology. Furthermore, commercial and private clients profit from the smart grid, as they may capture information about their current consumption in real time or can obtain these data from the Internet. The author of the contribution under consideration presents new approaches to access powerline communications that enable efficient communication between IPv6 based household meter and network station. The contribution under consideration describes the technologies used as well as practical experiences and initial results from field tests. Here insights from the integration of G3-PLC are in the foreground.

  9. 75 FR 10949 - Energy Conservation Program for Certain Commercial and Industrial Equipment: Test Procedure for...

    2010-03-09

    ... signal,'' ``power line carrier (PLC) control signal,'' and ``wireless control signal.'' It should be... comments on the NOPR, NEMA accepted DOE's interpretation and application of standby mode to metal halide....'' ``Power Line Carrier (PLC) Control Signal'' In the NOPR, DOE proposed a definition for the term ``power...

  10. 3D digital image correlation investigation of PLC effect in a new Ni-Co base superalloy

    Gao, Y.; Fu, S. H.; Cheng, T.; Huo, X.; Zhang, Q. C.

    2013-06-01

    Repeated plastic instability accompanying serrated yielding in stress-strain curves and localization of deformation is observed during plastic deformation of many metallic alloys when tensile specimens are deformed under certain experimental conditions of temperature, strain rate, and pre-deformation. This phenomenon is referred to as the Portevin- Le Chatelier (PLC) effect. TMW alloy, a newly developed Ni-Co base superalloy for aircraft engine application, also exhibit PLC effect during tensile test at temperatures ranging from 300 ° to 600 °, which are also the temperature range for engine working. In this paper, a 3D digital image correlation (3D DIC) measurement system was established to observe the localization of deformation (PLC band) in a tensile test performed on TMW alloy specimen at temperature of 400 °. The 3D DIC system, with displacement measurement accuracy up to 0.01 pixels and strain measurement accuracy up to 100 μɛ, has a high performance in displacement field calculation with more than 10000 points every second on a 3.1G Hz CPU computer. The test result shows that, the PLC bands are inclined at an angle of about 60° to the tensile axis. Unlike tensile test performed on aluminums alloy, the widths of PLC bands of TMW alloy specimen, ranging from 4 mm to 4.5 mm, are much greater than the specimen thickness (0.25 mm).

  11. Data communication between Panasonic PLC and PC using SerialPort control in C#.NET environment

    Gao, Ting; Gan, Xiaochuan; Ma, Liqun

    2015-02-01

    With the gradual promotion of Microsoft.NET platform, C# as an object-oriented programming language based on the platform has been widely used. Therefore, more attention is concentrated on how to achieve the communication between Panasonic PLC and PC efficiently and fast in C#.NET environment. In this paper, a method of using SerialPort control which could be used for achieving communication between PLC and PC is introduced. Meanwhile, the reason of abnormal thread when displayed the receiving data in form is analyzed and the programming method to solve the problem of thread safety is designed. Achieving the communication of Panasonic PLC and PC in C#.NET environment can give full play to the advantages of the .NET framework. It is practical, easy communication, high reliability and can combine with other measurement and calibration procedures effectively and conveniently. Configuration software is expensive and can only communicate with PLC separately, but these shortcomings can be solved in C#.NET environment. A well-designed user interface realized real-time monitoring of PLC parameters and achieved management and control integration. The experiment show that this method of data transfer is accurate and the program' running is stable.

  12. Construction of a multi-vender fieldbus system for PC-based control using soft PLC

    Park, J. H.; Park, Y. J.; Choi, J. M.; Park, J. S. [Hankyong National Univ., Ansung (Korea)

    2000-12-01

    The relationship between the IEC 61131-3 programming language and the fieldbus application that became necessary as an outcome of the recent automation technology was described.An educational text for the field users on the integration of the Input/Output (I/O) modules and on the IEC 61131-3 programming language was prepared. An attempt was made to include description of the various kind of the fieldbuses and promote understanding of the CAN and the AS-I bus using a practical approach. The profibus is most widely used in the world, and thus is an important and a standardized tool in the area of the process control. A method of integrating the profibus with the most commonly used I/O modules in the field was suggested. The most essential characteristics of the IEC 61131-3 programming language was also described. A method for the construction of the multi-vender I/O modules by the Soft PLC 4C of the softings was suggested. Various technical steps are necessary for the integration of the I/O modules by the soft PLC. An additional software is needed for the more intelligent devises possessing complex technical functions, such as the control valve, the AC driver among others. The 4C control by the softing which is an important industrial solution for the soft PLC was specifically designed for the profibus. So, an OPC server is needed to exchange between the other fieldbuses while the optimum performance is only achieved by using the profibus card by softing. This implies that the business aspect has played a major role for developing the profibus by softing and the domestic users need to pay careful attention to this point additional software tools, such as the PDM or the comuwinn II, are necessary in the process control area to operate a complex and instruments using the DP/PA segment coupler. 13 refs., 46 figs., 12 tabs. (Author)

  13. Generating Safety-Critical PLC Code From a High-Level Application Software Specification

    2008-01-01

    The benefits of automatic-application code generation are widely accepted within the software engineering community. These benefits include raised abstraction level of application programming, shorter product development time, lower maintenance costs, and increased code quality and consistency. Surprisingly, code generation concepts have not yet found wide acceptance and use in the field of programmable logic controller (PLC) software development. Software engineers at Kennedy Space Center recognized the need for PLC code generation while developing the new ground checkout and launch processing system, called the Launch Control System (LCS). Engineers developed a process and a prototype software tool that automatically translates a high-level representation or specification of application software into ladder logic that executes on a PLC. All the computer hardware in the LCS is planned to be commercial off the shelf (COTS), including industrial controllers or PLCs that are connected to the sensors and end items out in the field. Most of the software in LCS is also planned to be COTS, with only small adapter software modules that must be developed in order to interface between the various COTS software products. A domain-specific language (DSL) is a programming language designed to perform tasks and to solve problems in a particular domain, such as ground processing of launch vehicles. The LCS engineers created a DSL for developing test sequences of ground checkout and launch operations of future launch vehicle and spacecraft elements, and they are developing a tabular specification format that uses the DSL keywords and functions familiar to the ground and flight system users. The tabular specification format, or tabular spec, allows most ground and flight system users to document how the application software is intended to function and requires little or no software programming knowledge or experience. A small sample from a prototype tabular spec application is

  14. Melatonin potentiates glycine currents through a PLC/PKC signalling pathway in rat retinal ganglion cells.

    Zhao, Wen-Jie; Zhang, Min; Miao, Yanying; Yang, Xiong-Li; Wang, Zhongfeng

    2010-07-15

    In vertebrate retina, melatonin regulates various physiological functions. In this work we investigated the mechanisms underlying melatonin-induced potentiation of glycine currents in rat retinal ganglion cells (RGCs). Immunofluorescence double labelling showed that rat RGCs were solely immunoreactive to melatonin MT(2) receptors. Melatonin potentiated glycine currents of RGCs, which was reversed by the MT(2) receptor antagonist 4-P-PDOT. The melatonin effect was blocked by intracellular dialysis of GDP-beta-S. Either preincubation with pertussis toxin or application of the phosphatidylcholine (PC)-specific phospholipase C (PLC) inhibitor D609, but not the phosphatidylinositol (PI)-PLC inhibitor U73122, blocked the melatonin effect. The protein kinase C (PKC) activator PMA potentiated the glycine currents and in the presence of PMA melatonin failed to cause further potentiation of the currents, whereas application of the PKC inhibitor bisindolylmaleimide IV abolished the melatonin-induced potentiation. The melatonin effect persisted when [Ca(2+)](i) was chelated by BAPTA, and melatonin induced no increase in [Ca(2+)](i). Neither cAMP-PKA nor cGMP-PKG signalling pathways seemed to be involved because 8-Br-cAMP or 8-Br-cGMP failed to cause potentiation of the glycine currents and both the PKA inhibitor H-89 and the PKG inhibitor KT5823 did not block the melatonin-induced potentiation. In consequence, a distinct PC-PLC/PKC signalling pathway, following the activation of G(i/o)-coupled MT(2) receptors, is most likely responsible for the melatonin-induced potentiation of glycine currents of rat RGCs. Furthermore, in rat retinal slices melatonin potentiated light-evoked glycine receptor-mediated inhibitory postsynaptic currents in RGCs. These results suggest that melatonin, being at higher levels at night, may help animals to detect positive or negative contrast in night vision by modulating inhibitory signals largely mediated by glycinergic amacrine cells in the inner

  15. Duchenne muscular dystrophy carriers

    Matsumura, K.; Nakano, I.

    1989-01-01

    By means of magnetic resonance imaging (MRI), the proton spin-lattice relaxation times (T1 values) of the skeletal muscles were measured in Duchenne muscular dystrophy (DMD) carriers and normal controls. The bound water fraction (BWF) was calculated from the T1 values obtained, according to the fast proton diffusion model. In the DMD carriers, T1 values of the gluteus maximus and quadriceps femoris muscles were significantly higher, and BWFs of these muscles were significantly lower than in normal control. Degenerative muscular changes accompanied by interstitial edema were presumed responsible for this abnormality. No correlation was observed between the muscle T1 and serum creatine kinase values. The present study showed that MRI could be a useful method for studying the dynamic state of water in both normal and pathological skeletal muscles. Its possible utility for DMD carrier detection was discussed briefly. (orig.)

  16. Realization of Intelligent Measurement and Control System for Limb Rehabilitation Based on PLC and Touch Screen

    Liu, Xiangquan

    According to the treatment needs of patients with limb movement disorder, on the basis of the limb rehabilitative training prototype, function of measure and control system are analyzed, design of system hardware and software is completed. The touch screen which is adopt as host computer and man-machine interaction window is responsible for sending commands and training information display; The PLC which is adopt as slave computer is responsible for receiving control command from touch screen, collecting the sensor data, regulating torque and speed of motor by analog output according to the different training mode, realizing ultimately active and passive training for limb rehabilitation therapy.

  17. Design and realization of the waster level system based on PLC and configuration technology

    Hu Kaiming; Ge Yuanxiang; Fu Zhijian

    2012-01-01

    The process control experimental system takes the water level as the controlled object. In this system PLC is adopted as a controller and the electric valve for the actuator. Based on the water level system in the establishment of the mathematical model, the system uses PID algorithm, the PID parameters are tuning, MCGS configuration environment is built and debugs in the environment. Experiments show that the system is running smoothly, the overshoot is 18%, the setting time is about 3 min. The control indicators have reached the engineering requirements and the control effect is good. (authors)

  18. Institutional radioactive waste management in the Nuclear Research Institute Rez plc

    Kovarik, P.; Svoboda, K.; Podlaha, J.

    2008-01-01

    Nuclear research institute Rez, plc. (mentioned below as NRI) has had a dominant position in the area of the nuclear research and development in the Czech Republic, the Central and the Eastern Europe. Naturally, the radioactive waste management is an integral part of the nuclear industry, research and development. For that reason, there is Centre of the radioactive waste management (mentioned below as Centre) in the NRI. This Centre is engaged in the radioactive waste treatment, decontamination, characterisation, decommissioning and other relevant activities. This paper describes the system of technology and other information about institutional radioactive waste management in the NRI. (authors)

  19. The Interface Between Redundant Processor Modules Of Safety Grade PLC Using Mass Storage DPRAM

    Hwang, Sung Jae; Song, Seong Hwan; No, Young Hun; Yun, Dong Hwa; Park, Gang Min; Kim, Min Gyu; Choi, Kyung Chul; Lee, Ui Taek

    2010-01-01

    Processor module of safety grade PLC (hereinafter called as POSAFE-Q) developed by POSCO ICT provides high reliability and safety. However, POSAFEQ would have suffered a malfunction when we think taking place of abnormal operation by exceptional environmental. POSAFE-Q would not able to conduct its function normally in such case. To prevent these situations, the necessity of redundant processor module has been raised. Therefore, redundant processor module, NCPU-2Q, has been developed which has not only functions of single processor module with high reliability and safety but also functions of redundant processor

  20. Aplicación de la Tecnología PLC en la provincia del Azuay

    Jara Guapisaca, Claudio Xavier

    2006-01-01

    La Red PLC utiliza infraestructura ya instalada para atender a un mercado masivo, siendo una alternativa eficiente en términos de requerimientos de capital y tiempos de ejecución. La técnica es bastante sencilla de entender; consiste en acondicionar parte de las actuales infraestructuras eléctricas para que puedan transmitir señales regulares de baja frecuencia y otras por encima de la banda de 1 MHz, sin que se vea afectado el rendimiento eléctrico. Las señales de baja frecuencia (50 ó 60...

  1. A Modification of Gamma Surveymeter Dosemeter 3007A for Monitoring Use Ethernet by PLC T100MD Series

    Ikhsan Shobari; Subchan, M.; Syahrudin Yusuf; Sutomo Budihardjo

    2010-01-01

    It has been modified a gamma surveymeter Dosemeter 3007A. The Surveymeter represents analogous surveymeter, so that an interface for data acquisition is required. Acquisition system from surveymeter is added to the voltage amplifier module from 0 - 200 mV to 0 - 5 V. This voltage value will represent of doses 0 - 5 mR/hour. Hereinafter the analogous signal 0 - 5 V as signal of input to peripheral of PLC T100MD series. Data in the form of processed analogous signal presented at local display of PLC. For long distance monitoring, data have been sent to a computer from PLC by ethernet. After this modification, the surveymeter can be used to monitor from long distance. By using Internet Service Provider, monitoring can be done at any time and any where as long as network internet is available. (author)

  2. Perancangan Prototype Early Warning System pada Kontrol On/Off Belt Conveyor Menggunakan PLC Siemens S7-300

    Taufik Taufik

    2016-04-01

    Full Text Available Nowadays, automation system become an important aspect of the manufacturing process because could make integration manufacturing process on it more effective and more efficient. PLC or Programmable Logic Controller is one kind of automation system. Many industries use PLC as automation control device in the manufacturing process to control all kind of process. For example at transportation process of coals in generator industry. Coals could be burned because main elements of coals are carbon, hydrogen, and oxygen. Base on this prototype early warning system design, we get the result if sensor thermocouple detects temperature larger than setpoint temperature (it is 2000C, then PLC will give an order to shut down the output, that is a belt conveyor. The result of this prototype design could use at coals transportation as an early warning system. The design of prototype early warning system could detect and prevent fire because of the consequence of burned coals until spreading of fire could be avoided.

  3. Power Line Communication Experiment using Wavelet OFDM in U.S..

    Koga, Hisao; Kodama, Nobutaka

    Recently, the demand of high speed network in home is increasing, and PLC is expected as one of the solutions. We can see related researches on the high speed PLC system using a frequency band 2 MHz to 30 MHz. In this paper, we propose a wavelet based OFDM as a suitable method for realizing the high speed PLC system. The proposed wavelet OFDM method is composed of the M-band transmultiplexer which consists of the perfect reconstruction cosine-modulated filter bank. And the attenuation of the first side-lobe is above 35dB, which is a characteristic of the proposed method. As a result, we show that the proposed method has the inter-carrier interference characteristic which is superior to FFT-OFDM, and it also provides the flexible notch filter function which can reduce the influence on other communication systems existing in the communication band which the PLC uses. Finally, we describe that the simulation results about the BER characteristic of the proposed method in AWGN were almost the same as the theory, and that transmission rates which were measured by using prototype modems in a field test house in U.S. were above 35Mbps.

  4. Asymmetric Carrier Random PWM

    Mathe, Laszlo; Lungeanu, Florin; Rasmussen, Peter Omand

    2010-01-01

    index. The flat motor current spectrum generates an acoustical noise close to the white noise, which may improve the acoustical performance of the drive. The new carrier wave is easy to implement digitally, without employing any external circuits. The modulation method can be used in open, as well...

  5. Willis H Carrier

    Home; Journals; Resonance – Journal of Science Education; Volume 17; Issue 2. Willis H. Carrier - Father of Air Conditioning. R V Simha. General Article Volume 17 Issue 2 February 2012 pp 117-138. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/017/02/0117-0138 ...

  6. Process control through the incorporation of PLC networks in service radiation facilities

    Moehlmann, J.H.F.

    1990-01-01

    In order to ensure the smooth and safe running and operation of an irradiation facility, several regulations must be complied with, most of which are prescribed by the authorities. However, internal working regulations, based on years of practical experience, are of equal importance. The application of computers, micro-processors and PLCs, in combination with semi-conductor electronics, has improved process control considerably. Not only can every step in the process and even each detailed function be controlled, but also the combination of the different functions. By using PLC-systems in combination with computers, important data can be stored, recorded and presented in such a way that the technical staff can be warned in advance of breakdowns or undesirable deviations in the process parameters. Keeping a log of these data will help guarantee the correct functioning of the irradiation facility. It is even possible with these modern PLC techniques to monitor the control-console, so that each operation is recorded and accessible. (author)

  7. Real time control “es-dawet” mixer using dasboard based on PLC and WSN

    Siagian, Pandapotan; Hutauruk, Sindak; Kisno

    2017-09-01

    The aim of this study is to monitor and acquire the remote parameters like Speed control a DC Motor, IR Sensor, Temperature of pasteurize mix of ice cream, and send these real values over wireless network. A proposed system is dashboard monitoring system for PLC based system wirelessly using ZigBee protocol. To implement this a ZigBee model is connected to a programmed digital signal controller which would transmit the data to Zigbee coordinator which is connected to a PC through RS232 serial communication. Person can need only to send the reply about the process that is to be carried out and PLC will check the status of the web base sent by person and take the action according to it where wired communication is either more expensive or impossible due to physical conditions. A low cost system for measured the parameters of motor such as IR Sensor, Speed control a DC Motor by PWM and temperature with Zigbee protocol connectivity. A database is built to execute monitoring and to save the motor parameters received by radio frequency (RF) data acquisition system. Experimental results show that the proposed system is less costly, provides higher accuracy as well as safe and gives visual environment.

  8. Design and construction of automatic operating system of double chamber plasma nitriding device PLC based

    Saminto; Slamet Santosa; Eko Priyono

    2012-01-01

    The automatic operating system of double chamber plasma nitriding device has been done. The system is used for operating double chamber plasma nitriding automatically as according to the standard operating procedure by pressing push button on the human machine interface (HMI). The system consists of hardware and software. The hardware was constructed using main components T100MD1616+ PLC module and supported by temperature signal conditioner module, Wheatstone bridge module, isolated amplifier module and EMS 30A H Bridge motor driver module. A software program that is planted on T100MD1616+ PLC using ladder diagrams and Tbasic program. Test system functions performed by inserting a set values of temperature and pressure by pressing the button on the human machine interface (HMI). The test results show that the temperature control with a set of values 100 °C obtained stable coverage of 98 °C to 102 °C, (Δ ± 2 °C) with a 2% tolerance and the output voltage of the DAC is 2.436 volts to 2.913 volts. The pressure control with a set of values 2.169 x 10 -1 mbar obtained stable coverage of 1.995 x 10 -1 mbar to 2.205 x 10 -1 mbar, (Δ ± 0.105 x 10 -1 mbar) with a 5% tol. (author)

  9. Controlling the Filling and Capping Operation of a Bottling Plant using PLC and SCADA

    Kunal Chakraborty

    2015-03-01

    Full Text Available This paper presents basic stages of operation of a bottling plant, i.e. the filling and capping process. The main aim of our paper is to control the filling and capping section of a bottling plant simultaneously. At first a set of empty bottle is run by using a conveyer towards filling section, after the operation, the filled bottles are sent towards the capping section. After successful capping operation, the sealed bottles terminate towards exit and a new set of empty bottle arrive, in this way the process continues. This paper includes the method using which, a bunch of bottles can be filled and capped at one instant of time. This method has made the operation more flexible and time saving. The filling and capping operations are controlled using Programmable Logic Controllers (PLC, as the PLC’s are very much user-efficient, cost-effective and easy to control. By using PLC automation the whole process is kept under control. SCADA (Supervisory Control and Data Acquisition is used to monitor the process by means of a display system.

  10. PLC-based search and secure interlock system for the personnel safety in folded tandem ion accelerator

    Padmakumar, Sapna; Subramanyum, N.B.V.; Bhatt, Jignesh P.; Ware, Shailaja V.; Kansara, M.J.; Gupta, S.K.; Singh, P.

    2006-01-01

    Safety of the personnel is one of the key issues addressed in any accelerator project. The FOTIA facility at BARC is capable of operating under standard operation conditions without any radiation hazard. Even then for a safe and reliable operation of FOTIA a PLC (Programmable logic controller) based interlock system has been implemented. This interlocking system is compact, modular, flexible, robust and easy for troubleshooting. These advantages led to the popularity of PLC rather than using a relay-based system. This paper highlights the salient features of the search and secure interlock for the personal safety of FOTIA. (author)

  11. Sequence variation in the alpha-toxin encoding plc gene of Clostridium perfringens strains isolated from diseased and healthy chickens

    Abildgaard, L; Engberg, RM; Pedersen, Karl

    2009-01-01

    The aim of the present study was to analyse the genetic diversity of the alpha-toxin encoding plc gene and the variation in a-toxin production of Clostridium perfringens type A strains isolated from presumably healthy chickens and chickens suffering from either necrotic enteritis (NE) or cholangio......-hepatitis. The a-toxin encoding plc genes from 60 different pulsed-field gel electrophoresis (PFGE) types (strains) of C perfringens were sequenced and translated in silico to amino acid sequences and the a-toxin production was investigated in batch cultures of 45 of the strains using an enzyme...

  12. 75 FR 61363 - Airworthiness Directives; Rolls-Royce plc RB211-524 Series, -535 Series, RB211 Trent 700 Series...

    2010-10-05

    ...-0993; Directorate Identifier 2010-NE-08-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc... Federal holidays. Fax: (202) 493-2251. Contact Rolls-Royce plc, P.O. Box 31, Derby, DE24 8BJ, United... based on those comments. We will post all comments we receive, without change, to http://www.regulations...

  13. 75 FR 33738 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-524 Series and RB211 Trent 500, 700, and 800...

    2010-06-15

    ...-0562; Directorate Identifier 2009-NE-29-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR...-2251. Contact Rolls-Royce plc, P.O. Box 31, Derby, DE24 8BJ, United Kingdom; phone: 011 44 1332 242424... amend this proposed AD based on those comments. We will post all comments we receive, without change, to...

  14. 75 FR 27964 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-22B and RB211-524 Series Turbofan Engines

    2010-05-19

    ...-1157; Directorate Identifier 2009-NE-26-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR... p.m., Monday through Friday, except Federal holidays. Fax: (202) 493-2251. Contact Rolls-Royce plc... received by the closing date and may amend this proposed AD based on those comments. We will post all...

  15. Different Expression and Localization of Phosphoinositide Specific Phospholipases C in Human Osteoblasts, Osteosarcoma Cell Lines, Ewing Sarcoma and Synovial Sarcoma

    V.Vasco

    2017-06-01

    Full Text Available Background: Bone hardness and strength depends on mineralization, which involves a complex process in which calcium phosphate, produced by bone-forming cells, was shed around the fibrous matrix. This process is strictly regulated, and a number of signal transduction systems were interested in calcium metabolism, such as the phosphoinositide (PI pathway and related phospholipase C (PLC enzymes. Objectives: Our aim was to search for common patterns of expression in osteoblasts, as well as in ES and SS. Methods: We analysed the PLC enzymes in human osteoblasts and osteosarcoma cell lines MG-63 and SaOS-2. We compared the obtained results to the expression of PLCs in samples of patients affected with Ewing sarcoma (ES and synovial sarcoma (SS. Results: In osteoblasts, MG-63 cells and SaOS-2 significant differences were identified in the expression of PLC δ4 and PLC η subfamily isoforms. Differences were also identified regarding the expression of PLCs in ES and SS. Most ES and SS did not express PLCB1, which was expressed in most osteoblasts, MG-63 and SaOS-2 cells. Conversely, PLCB2, unexpressed in the cell lines, was expressed in some ES and SS. However, PLCH1 was expressed in SaOS-2 and inconstantly expressed in osteoblasts, while it was expressed in ES and unexpressed in SS. The most relevant difference observed in ES compared to SS regarded PLC ε and PLC η isoforms. Conclusion: MG-63 and SaOS-2 osteosarcoma cell lines might represent an inappropriate experimental model for studies about the analysis of signal transduction in osteoblasts

  16. Analysis of Information Leakages on Laser Printers in the Media of Electromagnetic Radiation and Line Conductions

    Ulaş, Cihan

    2016-01-01

    In this paper, the emissions of a laser printer, which may process classified information, are investigated in the media of electromagnetic radiation (ER), Power Line Conductors (PLC), and Signal Line Conductors (SLC). First, the candidate frequency points of CE are examined in the frequency domain. Second, the emitted signal is AM-demodulated with the proper bandwidth, and then sampled by a high storage oscilloscope in these frequency points. Third, the collected data is converted to 2D imag...

  17. Motor carrier evaluation program

    Portsmouth, James

    1992-01-01

    The U.S. Department of Energy-Headquarters (DOE-HQ), Transportation Management Program (TMP) has the overall responsibility to provide a well-managed transportation program for the safe, efficient, and economical transportation of DOE-owned materials. The DOE-TMP has established an excellent safety record in the transportation of hazardous materials including radioactive materials and radioactive wastes. This safety record can be maintained only through continued diligence and sustained effort on the part of the DOE-TMP, its field offices, and the contractors' organizations. Key elements in the DOE'S effective hazardous and radioactive materials shipping program are (1) integrity of packages, (2) strict adherence to regulations and procedures, (3) trained personnel, (4) complete management support, and (5) use of the best commercial carriers. The DOE Motor Carrier Evaluation Program was developed to better define the criteria and methodology needed to identify motor carriers for use in the transportation of Highway Route Controlled Quantities (HRCQ), Truck Load (TL) quantities of radioactive materials, hazardous materials and waste. (author)

  18. Carrier transport uphill. I. General

    Rosenberg, T; Wilbrandt, W

    1963-01-01

    A quantitative treatment of a carrier pump operating with two carrier forms C and Z is presented. Asymmetric metabolic reactions are assumed to transform Z into C on one and C into Z on the other side of the membrane, establishing a carrier cycle. The kinetical consequences of this mechanism...

  19. Fast Burst Synchronization for Power Line Communication Systems

    Lampe Lutz

    2007-01-01

    Full Text Available Fast burst synchronization is an important requirement in asynchronous communication networks, where devices transmit short data packets in an unscheduled fashion. Such a synchronization is typically achieved by means of a preamble sent in front of the data packet. In this paper, we study fast burst synchronization for power line communication (PLC systems operating below 500 kHz and transmitting data rates of up to about 500 kbps as it is typical in various PLC network applications. In particular, we are concerned with the receiver processing of the preamble signal and the actual design of preambles suitable for fast burst synchronization in such PLC systems. Our approach is comprehensive in that it takes into account the most distinctive characteristics of the power line channel, which are multipath propagation, highly varying path loss, and disturbance by impulse noise, as well as important practical constraints, especially the need for spectral shaping of the preamble signal and fast adjustment of the automatic gain control (AGC. In fact, we regard the explicit incorporation of these various requirements into the preamble design as the main contribution of this work. We devise an optimization criterion and a stochastic algorithm to search for suitable preamble sequences. A comprehensive performance comparison of a designed and two conventional preambles shows that the designed sequence is superior in terms of (a fast burst synchronization in various transmission environments, (b fast AGC adjustment, and (c compliance of its spectrum with the spectral mask applied to the data transmit signal.

  20. Safety and environmental aspects in LNG carrier design

    Yoneyama, Takashi [Mitsui Shipbuilding and Engineering Co. Ltd., Tokyo (Japan)

    1997-06-01

    `Safety and Reliability` has been and will continue to be a key phr ase in marine transportation of LNG. Mitsui Engineering and Shipbuilding Co.,Ltd. has utilized its all expertise and state of art technologies to realize this objective, resulting in exceptionally successful operations of LNG carrier built by the Co. In line with growing global concern about environmental issues, we need to pay more attention to the environmental aspects of the design and construction of LNG carriers. Accordingly, in this paper, we present some topics related safety and environmental concerns which need to be taken into consideration in LNG carriers design and construction. (Author). 7 figs.

  1. Safety and environmental aspects in LNG carrier design

    Takashi Yoneyama

    1997-01-01

    'Safety and Reliability' has been and will continue to be a key phr ase in marine transportation of LNG. Mitsui Engineering and Shipbuilding Co.,Ltd. has utilized its all expertise and state of art technologies to realize this objective, resulting in exceptionally successful operations of LNG carrier built by the Co. In line with growing global concern about environmental issues, we need to pay more attention to the environmental aspects of the design and construction of LNG carriers. Accordingly, in this paper, we present some topics related safety and environmental concerns which need to be taken into consideration in LNG carriers design and construction. (Author). 7 figs

  2. The Cish SH2 domain is essential for PLC-γ1 regulation in TCR stimulated CD8+ T cells.

    Guittard, Geoffrey; Dios-Esponera, Ana; Palmer, Douglas C; Akpan, Itoro; Barr, Valarie A; Manna, Asit; Restifo, Nicholas P; Samelson, Lawrence E

    2018-03-28

    Cish, participates within a multi-molecular E3 ubiquitin ligase complex, which ubiquitinates target proteins. It has an inhibitory effect on T cell activation mediated by PLC-γ1 regulation, and it functions as a potent checkpoint in CD8 + T cell tumor immunotherapy. To study the structural and functional relationships between Cish and PLC-γ1 during CD8 + T cell activation, we tested mutants of the Cish-SH2 (R107K) and D/BC (L222Q, C226Q) domains. We confirmed that Cish-SH2-specific binding was essential for PLC-γ1 ubiquitination and degradation. This domain was essential for the Cish-mediated inhibition of Ca 2+ release upon TCR stimulation. No effect on inhibition of cytokine release was observed with SH2 or D/BC mutants, although the absence of Cish led to an increased release of IFN-γ and TNF-α. Using imaging we showed that Cish was expressed mostly in the cytoplasm and we did not see any Cish clustering at the plasma membrane upon stimulation. We conclude that the Cish-SH2 domain is essential for PLC-γ1 regulation in TCR-stimulated CD8 + T cells.

  3. 75 FR 27973 - Airworthiness Directives; Rolls-Royce plc RB211-524C2 Series Turbofan Engines

    2010-05-19

    ... RB211-524C2 Series Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice... Rolls-Royce plc (RR) model RB211-524C2-19 and RB211-524C2-B-19 turbofan engines. These engines are...

  4. Design and application of the high-voltage DC power-supply control system based on PLC

    Huang Yiyun; Zheng Guanghua; Wu Junshuan; Yang Chunsheng; Hu Huaichuan

    2002-03-01

    The design and application of A kind of high-voltage DC power-supply control system based on PLC is referred, in addition, KingView is used to monitor the system in real time and manage the man-machine conversation ideally

  5. 78 FR 23316 - The Royal Bank of Scotland plc, et al.; Notice of Application and Temporary Order

    2013-04-18

    ... plc, et al.; Notice of Application and Temporary Order April 12, 2013. AGENCY: Securities and Exchange Commission (``Commission''). ACTION: Temporary order and notice of application for a permanent order under... application for a permanent order. Applicants have also applied for a permanent order. APPLICANTS: The Royal...

  6. 75 FR 58290 - Airworthiness Directives; Rolls-Royce plc RB211 Trent 700 and Trent 800 Series Turbofan Engines

    2010-09-24

    ... Airworthiness Directives; Rolls-Royce plc RB211 Trent 700 and Trent 800 Series Turbofan Engines AGENCY: Federal... or increase the scope of the AD. Costs of Compliance Based on the service information, we estimate.... Required parts would cost about $15,000 per product. Based on these figures, we estimate the cost of the AD...

  7. 75 FR 50877 - Airworthiness Directives; Rolls-Royce plc RB211-524C2 Series Turbofan Engines

    2010-08-18

    ... Airworthiness Directives; Rolls-Royce plc RB211-524C2 Series Turbofan Engines AGENCY: Federal Aviation... require adopting the AD as proposed. Costs of Compliance Based on the service information, we estimate.... Required parts will cost about $25,000 per product. Based on these figures, we estimate the cost of the AD...

  8. 75 FR 28655 - Rexam Closure Systems, Inc. a Subsidiary of Rexam PLC Including On-Site Leased Workers From...

    2010-05-21

    ... Hamlet, NC; Amended Certification Regarding Eligibility To Apply for Worker Adjustment Assistance In..., applicable to the workers of Rexam Closure Systems, Inc., a subsidiary of Rexam PLC, Hamlet, North Carolina... paid through Owens Illinois Manufacturing, Hamlet, North Carolina, who became totally or partially...

  9. MHC class I signaling in T cells leads to tyrosine kinase activity and PLC-gamma 1 phosphorylation

    Skov, S; Odum, Niels; Claesson, M H

    1995-01-01

    phosphorylation and the subsequent calcium response. The early tyrosine kinase activity was found to be dependent on expression of the TCR/CD3 complex and the CD45 molecule on the surface of the T cells. Furthermore, MHC-I cross-linking was shown to tyrosine phosphorylate PLC-gamma 1 (phospholipase C-gamma 1...

  10. The new control system of HLS linac and transport line

    Liu Gongfa; Li Weimin; Li Jingyi; Li Chuan; Cheng Liping; Bao Xun; Wang Jigang; Xuan Ke

    2005-01-01

    The new linac and transport line control system of Hefei Light Source (HLS) is a distributed control system based on EPICS (Experimental Physics and Industrial Control System). Industrial PC (IPC) is widely used as not only Input/Output Controller (IOC) but also device controller. Besides industrial PC, PLC and microcontroller are also used as device controllers. The software for industrial PC based device controller is developed based on VxWorks real-time operating system. The software for PLC and microcontroller are written with ladder software package and assemble language, respectively. PC with Linux and SUN workstation with Solaris are used as operator interfaces (OPI). High level control is made up of some EPICS tools and Tcl/Tk scripts. (authors)

  11. Transmission Characteristics of an OFDM signal for Power Line Communication System with High Bit Rate

    Mori, Akira; Watanabe, Yosuke; Tokuda, Masamitsu; Kawamoto, Koji

    In this paper, we measured what influence the sinusoidal transmission characteristics of the electric power line with various forms gave to the transmission characteristic of OFDM (Orthogonal Frequency Division Multiplexing) signal through PLC (power line communication system) modem. We classified the electric power line transmission line with various forms in a real environment into two basic elements, which are an outlet type branch and a switch type branch. Next, PHY rate (Physical rate) is measured for each basic element connected with the PLC modem. At this time, the transmission characteristics of the electric power line are simulated from measured data. OFDM sending and receiving systems are composed on the computer, and the PHY rate is simulated. By comparing with measured and calculated values, it is revealed that PHY rate of PLC modem is most affected in the case of the power line transmission characteristics having broad band and high level attenuation and group delay variation, and is not affected in the case of that having narrow band attenuation and group delay variation.

  12. Decommissioning of the gaseous diffusion plant at BNF plc Capenhurst in the UK

    Clements, D.W.; Cross, J.R.

    1993-01-01

    Since 1982, a gaseous diffusion plant located at the British Nuclear Fuels plc (BNFL) site at Capenhurst in the United Kingdom, has been undergoing decontamination, decommissioning, and dismantling. By March 1994, the decontamination and decommissioning activities will be complete with 99% of the materials used to construct the plant recycled to the environment as clean material. This paper describes the history of the decontamination, decommissioning, dismantling, and disposal program. Reference is made to the scale of the project and to the special techniques developed, particularly in the areas of size reduction, decontamination, and protection of personnel and the environment. The quantities of material involved that require decontamination and release levels for recycling materials in the U.K. metals market are discussed

  13. On the determination of the colour term in the P-L-C relation for cepheids

    Feast, M.W.; Balona, L.A.

    1980-01-01

    Recent speculations that the coefficient of the colour term in the P-L-C relation for cepheids may be considerably different from 2.7 are inconsistent with existing data on LMC cepheids. The colour coefficient recently derived is not significantly affected by taking into account an absorption induced correlation between the errors in 0 > and ( 0 > - 0 >). The computer simulation which shows the bias introduced in the colour coefficient when this is derived by an inappropriate method (simple least squares) is consistent with theory and in accord with actual results in the LMC. This gives added confidence in the unbiased nature of the results derived by a maximum likelihood method which takes into account errors in each variable. (author)

  14. Design of Measurement and Control System of Composite Fast Transfer Switch Based on PLC

    ZHANG Hong-yi

    2017-06-01

    Full Text Available The fast transfer switch gets more extensive application in the power supply system along with the raising of power supply requirement for continuity and reliability in the sensitivity loads such as in airport,military place,hospital and large scale industrial production line. Therefore it is important that how to make fast transfer switch run safely and reliably. The paper expatiated the structure and principle of a fast transfer switch based on mechanical and electronic compound technology,and,according to the basic requirement and the characteristic of the fast transfer switch,a PLC mastered measuring and controlling system has been designed to raise the operation reliability of the fast transfer switch.

  15. The PLC-based Industrial Temperature Control System: Design and Implementation

    Wei Fanjie

    2017-01-01

    Full Text Available Targeting at the problem of slow response and low accuracy of the automatic temperature control system for material processing and boiler heating, a new design method is proposed to work with the PLC-based temperature control system, where the box temperature control may be achieved through the fan and the heating plate. The hardware design and software design of the system are analyzed in detail. In this paper, a combination of the traditional PID control and the more popular fuzzy control is taken as the control program to achieve the overall design of the control algorithm. Followed by the simulation in the MATLAB software, the designed system is highlighted by its the characteristics of impressive stability, precision and robustness.

  16. A Component-Based Modeling and Validation Method for PLC Systems

    Rui Wang

    2014-05-01

    Full Text Available Programmable logic controllers (PLCs are complex embedded systems that are widely used in industry. This paper presents a component-based modeling and validation method for PLC systems using the behavior-interaction-priority (BIP framework. We designed a general system architecture and a component library for a type of device control system. The control software and hardware of the environment were all modeled as BIP components. System requirements were formalized as monitors. Simulation was carried out to validate the system model. A realistic example from industry of the gates control system was employed to illustrate our strategies. We found a couple of design errors during the simulation, which helped us to improve the dependability of the original systems. The results of experiment demonstrated the effectiveness of our approach.

  17. STS-55 MS1/PLC Ross monitors Payload Specialist Walter's Anthrorack activity

    1993-01-01

    STS-55 German Payload Specialist 1 Ulrich Walter breathes into Rack 9 Anthrorack (AR) (Human Physiology Laboratory) device for Pulmonary Perfusion and Ventilation During Rest and Exercise experiment while working inside the Spacelab Deutsche 2 (SL-D2) science module aboard the Earth-orbiting Columbia, Orbiter Vehicle (OV) 102. Seated on the bicycle ergometer, Walter utilizes the respiratory monitoring system, part of a broad battery of experiments designed to investigate human physiology under microgravity conditions. In the background, Mission Specialist 1 (MS1) and Payload Commander (PLC) Jerry L. Ross monitors Walter's activity. Walter represents the German Aerospace Research Establishment (DLR) on the 10-day SL-D2 mission. Visible on the aft end cone are a fire extinguisher and the Crew Telesupport Experiment (CTE) Macintosh portable computer mounted on an adjustable work platform.

  18. Comparative diagnostic efficacy of recombinant LLO and PI-PLC-based ELISAs for detection of listeriosis in animals.

    Suryawanshi, Rahul D; Malik, Satya Veer Singh; Jayarao, Bhushan; Chaudhari, Sandeep P; Savage, Emily; Vergis, Jess; Kurkure, Nitin V; Barbuddhe, Sukhadeo B; Rawool, Deepak B

    2017-06-01

    The present study for the first time evaluates the serodiagnostic efficacy of two recombinant antigens namely, listeriolysin O (rLLO) and phosphatidyl-inositol phospholipase C (rPI-PLC). Indirect ELISA with the above recombinant antigens was used on samples collected from bovines (n=106), goats (n=138) and pigs (n=92) having either a history of abortion, emaciation and/or apparently healthy animals. Isolation of Listeria was attempted from the blood samples using USDA-FSIS method. On screening of test sera by rLLO-based ELISA, antibodies against anti-listeriolysin O (ALLO) were observed in goats (22.46%), bovines (15.10%) and pigs (16.31%). As advocated, after adsorption of positive serum samples with streptolysin O (SLO), the seropositivity for ALLO was marginally reduced (p>0.05) in goats (21.73%) and bovines (10.38%), whereas, in pigs the reduction (5.43%) was significant (pPLC-based ELISA revealed higher non-specific seropositivity for antilisterial antibodies in goats (45.65%), bovines (31.13%) and pigs (8.69%). Further, on comparing the seropositivity with isolation rate, of the 16 animals that were culturally-positive for L. monocytogenes, 15 showed ALLO positivity in unadsorbed as well as SLO-adsorbed sera by rLLO-based ELISA, however, rPI-PLC-based ELISA could detect seropositivity in only 5 animals. Moreover, rPI-PLC-based ELISA also showed seropositivity in those animals (7/30) that were culturally positive for other Listeria spp. In conclusion, rLLO can serve as a better antigen than rPI-PLC in ELISA for the serodiagnosis of listeriosis in animals; however, prior adsorption of test sera with SLO is required to avoid false positive results. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Pancreatic acini possess endothelin receptors whose internalization is regulated by PLC-activating agents.

    Hildebrand, P; Mrozinski, J E; Mantey, S A; Patto, R J; Jensen, R T

    1993-05-01

    Endothelin-1 (ET-1) and ET-3 mRNA have been found in the pancreas. We investigated the ability of ET-1, ET-2, and ET-3 to interact with and alter dispersed rat pancreatic acinar cell function. Radiolabeled ETs bound in a time- and temperature-dependent fashion, which was specific and saturable. Analysis demonstrated two classes of receptors, one class (ETA receptor) had a high affinity for ET-1 but a low affinity for ET-3, and the other class (ETB receptor) had equally high affinities for ET-1 and ET-3. No specific receptor for ET-2 was identified. Pancreatic secretagogues that activate phospholipase C (PLC) inhibited binding of 125I-labeled ET-1 (125I-ET-1) or 125I-ET-3, whereas agents that act through adenosine 3',5'-cyclic monophosphate (cAMP) did not. A23187 had no effect on 125I-ET-1 or 125I-ET-3 binding, whereas the phorbol ester 12-O-tetradecanoylphorbol 13-acetate reduced binding. The effect of cholecystokinin octapeptide (CCK-8) was mediated through its own receptor. Stripping of surface bound ligand studies demonstrated that both 125I-labeled ET-1 and 125I-labeled ET-3 were rapidly internalized. CCK-8 decreased the internalization but did not change the amount of surface bound ligand. Endothelins neither stimulate nor alter changes in enzyme secretion, intracellular calcium, cAMP, or [3H]inositol trisphosphate (IP3). This study demonstrates the presence of ETA and ETB receptors on rat pancreatic acini; occupation of both receptors resulted in rapid internalization, which is regulated by PLC-activating secretagogues. Occupation of either ET receptor did not alter intracellular calcium, cAMP, IP3, or stimulate amylase release.

  20. Motion of a carrier with a mobile load along a rough inclined plane

    Bilchenko, G. G.

    2018-03-01

    The mechanical system consisting of a carrier and a load is considered. The load can move respectively the carrier according to the preset given motion law. The carrier motion from rest caused the load motion is investigated. The carrier can move translationally along rectilinear trajectory along rough inclined plane. The trajectory is the line of the greatest descent. The axis of rectilinear channel along which the load moves is situated in vertical plane containing the carrier trajectory. The Coulomb model is taken to describe the friction forces on sloped plane. Differential equations of motion of carrier with load are obtained. The sufficient condition of the carrier motion without detachment from inclined plane is given. For two special cases of the channel installation angle and the plane inclination angle combination the motion types are described. The computation experiments results are presented: the carrier motions in the special cases are illustrated, the phase portraits for some types of motions are constructed.

  1. Autonomous component carrier selection

    Garcia, Luis Guilherme Uzeda; Pedersen, Klaus; Mogensen, Preben

    2009-01-01

    management and efficient system operation. Due to the expected large number of user-deployed cells, centralized network planning becomes unpractical and new scalable alternatives must be sought. In this article, we propose a fully distributed and scalable solution to the interference management problem...... in local areas, basing our study case on LTE-Advanced. We present extensive network simulation results to demonstrate that a simple and robust interference management scheme, called autonomous component carrier selection allows each cell to select the most attractive frequency configuration; improving...... the experience of all users and not just the few best ones; while overall cell capacity is not compromised....

  2. Some remarks on the carrier distillation method

    Avni, R.; Chaput, M.

    1961-01-01

    The method described by SCRIBNER and MULLIN makes possible the spectrographic analysis of the refractory oxides of uranium and plutonium. It uses a distillation of the elements which is more or less selective. The influence of the carrier is the subject of as many hypotheses as there are parameters involved in the process. The measurements of the arc temperature carried out on the leading edges of the vibration bands and of certain copper lines have made it possible to show the influence of the nature of the carrier and to establish a relationship between the values of the excitation potentials of the atoms and the temperatures produced. Further, this result makes it possible to explain certain contradictions between the principle of a fractional distillation in the arc which is incompatible with the refractory properties of certain elements and their spectrographic sensitivity. (author) [fr

  3. Histidine-lysine peptides as carriers of nucleic acids.

    Leng, Qixin; Goldgeier, Lisa; Zhu, Jingsong; Cambell, Patricia; Ambulos, Nicholas; Mixson, A James

    2007-03-01

    With their biodegradability and diversity of permutations, peptides have significant potential as carriers of nucleic acids. This review will focus on the sequence and branching patterns of peptide carriers composed primarily of histidines and lysines. While lysines within peptides are important for binding to the negatively charged phosphates, histidines are critical for endosomal lysis enabling nucleic acids to reach the cytosol. Histidine-lysine (HK) polymers by either covalent or ionic bonds with liposomes augment transfection compared to liposome carriers alone. More recently, we have examined peptides as sole carriers of nucleic acids because of their intrinsic advantages compared to the bipartite HK/liposome carriers. With a protocol change and addition of a histidine-rich tail, HK peptides as sole carriers were more effective than liposomes alone in several cell lines. While four-branched polymers with a primary repeating sequence pattern of -HHK- were more effective as carriers of plasmids, eight-branched polymers with a sequence pattern of -HHHK- were more effective as carriers of siRNA. Compared to polyethylenimine, HK carriers of siRNA and plasmids had reduced toxicity. When injected intravenously, HK polymers in complex with plasmids encoding antiangiogenic proteins significantly decreased tumor growth. Furthermore, modification of HK polymers with polyethylene glycol and vascular-specific ligands increased specificity of the polyplex to the tumor by more than 40-fold. Together with further development and insight on the structure of HK polyplexes, HK peptides may prove to be useful as carriers of different forms of nucleic acids both in vitro and in vivo.

  4. LIQUIFIED NATURAL GAS (LNG CARRIERS

    Daniel Posavec

    2010-12-01

    Full Text Available Modern liquefied natural gas carriers are double-bottom ships classified according to the type of LNG tank. The tanks are specially designed to store natural gas cooled to -161°C, the boiling point of methane. Since LNG is highly flammable, special care must be taken when designing and operating the ship. The development of LNG carriers has begun in the middle of the twentieth century. LNG carrier storage space has gradually grown to the current maximum of 260000 m3. There are more than 300 LNG carriers currently in operation (the paper is published in Croatian.

  5. Activation of PLC by an endogenous cytokine (GBP) in Drosophila S3 cells and its application as a model for studying inositol phosphate signalling through ITPK1.

    Zhou, Yixing; Wu, Shilan; Wang, Huanchen; Hayakawa, Yoichi; Bird, Gary S; Shears, Stephen B

    2012-12-01

    Using immortalized [3H]inositol-labelled S3 cells, we demonstrated in the present study that various elements of the inositol phosphate signalling cascade are recruited by a Drosophila homologue from a cytokine family of so-called GBPs (growth-blocking peptides). HPLC analysis revealed that dGBP (Drosophila GBP) elevated Ins(1,4,5)P3 levels 9-fold. By using fluorescent Ca2+ probes, we determined that dGBP initially mobilized Ca2+ from intracellular pools; the ensuing depletion of intracellular Ca2+ stores by dGBP subsequently activated a Ca2+ entry pathway. The addition of dsRNA (double-stranded RNA) to knock down expression of the Drosophila Ins(1,4,5)P3 receptor almost completely eliminated mobilization of intracellular Ca2+ stores by dGBP. Taken together, the results of the present study describe a classical activation of PLC (phospholipase C) by dGBP. The peptide also promoted increases in the levels of other inositol phosphates with signalling credentials: Ins(1,3,4,5)P4, Ins(1,4,5,6)P4 and Ins(1,3,4,5,6)P5. These results greatly expand the regulatory repertoire of the dGBP family, and also characterize S3 cells as a model for studying the regulation of inositol phosphate metabolism and signalling by endogenous cell-surface receptors. We therefore created a cell-line (S3ITPK1) in which heterologous expression of human ITPK (inositol tetrakisphosphate kinase) was controlled by an inducible metallothionein promoter. We found that dGBP-stimulated S3ITPK1 cells did not synthesize Ins(3,4,5,6)P4, contradicting a hypothesis that the PLC-coupled phosphotransferase activity of ITPK1 [Ins(1,3,4,5,6)P5+Ins(1,3,4)P3→Ins(3,4,5,6)P4+Ins(1,3,4,6)P4] is driven solely by the laws of mass action [Chamberlain, Qian, Stiles, Cho, Jones, Lesley, Grabau, Shears and Spraggon (2007) J. Biol. Chem. 282, 28117-28125]. This conclusion represents a fundamental breach in our understanding of ITPK1 signalling.

  6. 76 FR 24793 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-524 Series and RB211 Trent 500, 700, and 800...

    2011-05-03

    ... Airworthiness Directives; Rolls-Royce plc (RR) RB211-524 Series and RB211 Trent 500, 700, and 800 Series... the AD. Costs of Compliance Based on the service information, we estimate that this AD would affect...

  7. Dynamics of plc gene transcription and α-toxin production during growth of Clostridium perfringens strains with contrasting α-toxin production

    Abildgaard, Lone; Schramm, Andreas; Rudi, Knut

    2009-01-01

    The aim of the present study was to investigate transcription dynamics of the α-toxin-encoding plc gene relative to two housekeeping genes (gyrA and rplL) in batch cultures of three Clostridium perfringens strains with low, intermediate, and high levels of α-toxin production, respectively. The plc...... transcript level was always low in the low α-toxin producing strain. For the two other strains, plc transcription showed an inducible pattern and reached a maximum level in the late exponential growth phase. The transcription levels were however inversely correlated to α-toxin production for the two strains....... We propose that this discrepancy is due to differences in plc translation rates between the strains and that strain-specific translational rates therefore must be determined before α-toxin production can be extrapolated from transcript levels in C. perfringens....

  8. Study on the Development of Builtin PLC%内嵌式PLC的设计与实现

    刘家亮; 熊晓红; 黄树槐

    2001-01-01

    介绍了PLC编程语言——语句表的结构和特点,讨论了语句表解释程序的词法分析和语法分析技术,以及运用面向对象的编程思想、构造语句表解释程序,实现内嵌式PLC等问题。%In this thesis, the architecture and character of the PLC languageSTL are introduced. And then, the structure of STL interpreting program and the technique of lexical analysis and syntax analysis are discussed. Develop the STL interpreting program with the idea of OOP(objectoriented programming), realized the builtin PLC are also attempted.

  9. Měření výpočetního výkonu PLC PFC200

    Majchrák, František

    2017-01-01

    V práci sa analyzujú možnosti merania výpočetného výkonu PLC PFC200 od firmy WAGO. Prvú časť práce venujem priblíženiu funkčnosti automatu, jeho využitiu, jednotlivým možnostiam programovania, zoznamujem sa s implementáciou vlastných programových blokov v prostredí embedded Linux a zisťujem jeho prepojenie s PLC prostredím. V druhej časti práce sa sústredím na meranie výkonu, jeho typy, popis certifikovaných meraní a jeho celkové zhodnotenie. V poslednej časti je vysvetlená aplikácia, ktorá z...

  10. First Experience with PLC, OPC and BridgeVIEW in the context of the HMPID liquid distribution prototype

    Maatta, E; CERN. Geneva; Swoboda, Detlef; Lecoeur, G

    1999-01-01

    The TESt (Test and Evaluation Station) [3] project consists in the construction of a stand alone unit for a specific sub-system of an ALICE detector in order to gain first experience with commercial products for detector control. Although the control system includes only a small number of devices and is designed for a particular application, it covers nevertheless all layers of a complete system and can be extended or used in different applications. The control system prototype has been implemented for the Perfluorohexane (C6F14) liquid distribution of the ALICE-HMPID (High-Momentum Particle IDentification)[5]. This report presents the experience acquired while developing the control system with off the shelf items: National Instruments BridgeVIEW [6] supervision software, SIEMENS PLC S7-300 [7] and the programming tool STEP 7. The OPC standard (OLE [12] for Process Control) [8] was used for the communication between BridgeVIEW and the PLC.

  11. Simulation of a Narrowband Power Line Communications System over Medium Voltage

    Nikolaos Chiotellis

    2016-03-01

    Full Text Available Narrowband Power Line Communications (NB-PLCs are investigated as an alternative option for transferring low rate smart grid (SG data via Medium Voltage (MV power lines. In this framework, two variants of orthogonal frequency division multiplexing are examined, namely Filtered-OFDM (F-OFDM and Wavelet-OFDM (W-OFDM, in an attempt to determine which of them is capable of transmitting low rate SG data to greater distances over non-branched MV power lines. The reach of NB-PLC signals via MV power lines is estimated, taking into account the transfer function of the relevant PLC channels and noise mechanisms as well as the specific features of the two modulation options under consideration. Simulations show that NB-PLC transmission constitutes a technically feasible and economically affordable option for exchanging low rate data with remote SG nodes dispersed over the MV grid. Moreover, simulations show that F-OFDM allows low rate data transmission to considerably greater distances compared to W-OFDM.

  12. Protease-activated receptor-2 stimulates intestinal epithelial chloride transport through activation of PLC and selective PKC isoforms.

    van der Merwe, Jacques Q; Moreau, France; MacNaughton, Wallace K

    2009-06-01

    Serine proteases play important physiological roles through their activity at G protein-coupled protease-activated receptors (PARs). We examined the roles that specific phospholipase (PL) C and protein kinase (PK) C (PKC) isoforms play in the regulation of PAR(2)-stimulated chloride secretion in intestinal epithelial cells. Confluent SCBN epithelial monolayers were grown on Snapwell supports and mounted in modified Ussing chambers. Short-circuit current (I(sc)) responses to basolateral application of the selective PAR(2) activating peptide, SLIGRL-NH(2), were monitored as a measure of net electrogenic ion transport caused by PAR(2) activation. SLIGRL-NH(2) induced a transient I(sc) response that was significantly reduced by inhibitors of PLC (U73122), phosphoinositol-PLC (ET-18), phosphatidylcholine-PLC (D609), and phosphatidylinositol 3-kinase (PI3K; LY294002). Immunoblot analysis revealed the phosphorylation of both PLCbeta and PLCgamma following PAR(2) activation. Pretreatment of the cells with inhibitors of PKC (GF 109203X), PKCalpha/betaI (Gö6976), and PKCdelta (rottlerin), but not PKCzeta (selective pseudosubstrate inhibitor), also attenuated this response. Cellular fractionation and immunoblot analysis, as well as confocal immunocytochemistry, revealed increases of PKCbetaI, PKCdelta, and PKCepsilon, but not PKCalpha or PKCzeta, in membrane fractions following PAR(2) activation. Pretreatment of the cells with U73122, ET-18, or D609 inhibited PKC activation. Inhibition of PI3K activity only prevented PKCdelta translocation. Immunoblots revealed that PAR(2) activation induced phosphorylation of both cRaf and ERK1/2 via PKCdelta. Inhibition of PKCbetaI and PI3K had only a partial effect on this response. We conclude that basolateral PAR(2)-induced chloride secretion involves activation of PKCbetaI and PKCdelta via a PLC-dependent mechanism resulting in the stimulation of cRaf and ERK1/2 signaling.

  13. Comparative response time and fault logging with a PLC and supervisory software and a standalone unit developed for recording

    Baldaconi, Ricardo H.; Costa, Fabio E. da

    2017-01-01

    The Cobalt-60 irradiator of IPEN / CNEN, a category IV facility, has a security system for inter locking doors or exposure of radioactive sources made simultaneously by a programmable logic controller (PLC) model S7-200 from Siemens and a relay logic. From a set of information, both systems work together opening doors or exposing the sources. All incoming and outgoing information are sent serially via EIA232 communication to a personal computer with Windows® platform for a supervisory program which provides the monitoring of the entire process by a synoptic table on the computer screen and is also intended to keep records of all events on the computer's hard drive. A deficiency was found for the process of sending events via serial communication (EIA232) from PLC to the supervisory program. When failure occurred in a very short time, the PLC always took the right decision, but the registration process that had to go through the Windows® timeshare lost the information. In the previous work developed a standalone electronics unit connected to the inputs and outputs of the security system, fully optocoupled to avoid any interference to the security system that records each event on a memory card. In this work, for checking the unit developed record time ability, transients incoming signals for simulating failures, were injected at security system inputs and the response time of security system, supervisory program and the autonomous unity were measured and compared. (author)

  14. Development of Remote Monitoring and a Control System Based on PLC and WebAccess for Learning Mechatronics

    Wen-Jye Shyr

    2013-02-01

    Full Text Available This study develops a novel method for learning mechatronics using remote monitoring and control, based on a programmable logic controller (PLC and WebAccess. A mechatronics module, a Web-CAM and a PLC were integrated with WebAccess software to organize a remote laboratory. The proposed system enables users to access the Internet for remote monitoring and control of the mechatronics module via a web browser, thereby enhancing work flexibility by enabling personnel to control mechatronics equipment from a remote location. Mechatronics control and long-distance monitoring were realized by establishing communication between the PLC and WebAccess. Analytical results indicate that the proposed system is feasible. The suitability of this system is demonstrated in the department of industrial education and technology at National Changhua University of Education, Taiwan. Preliminary evaluation of the system was encouraging and has shown that it has achieved success in helping students understand concepts and master remote monitoring and control techniques.

  15. Comparative response time and fault logging with a PLC and supervisory software and a standalone unit developed for recording

    Baldaconi, Ricardo H., E-mail: ricardohovacker@hotmail.com [Escola Senai Roberto Simonsen, Educação e Tecnologia, Sao Paulo, SP (Brazil); Costa, Fabio E. da, E-mail: fecosta@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    The Cobalt-60 irradiator of IPEN / CNEN, a category IV facility, has a security system for inter locking doors or exposure of radioactive sources made simultaneously by a programmable logic controller (PLC) model S7-200 from Siemens and a relay logic. From a set of information, both systems work together opening doors or exposing the sources. All incoming and outgoing information are sent serially via EIA232 communication to a personal computer with Windows® platform for a supervisory program which provides the monitoring of the entire process by a synoptic table on the computer screen and is also intended to keep records of all events on the computer's hard drive. A deficiency was found for the process of sending events via serial communication (EIA232) from PLC to the supervisory program. When failure occurred in a very short time, the PLC always took the right decision, but the registration process that had to go through the Windows® timeshare lost the information. In the previous work developed a standalone electronics unit connected to the inputs and outputs of the security system, fully optocoupled to avoid any interference to the security system that records each event on a memory card. In this work, for checking the unit developed record time ability, transients incoming signals for simulating failures, were injected at security system inputs and the response time of security system, supervisory program and the autonomous unity were measured and compared. (author)

  16. Remediation of old environmental liabilities in the Nuclear Research Institute Rez plc

    Svoboda, Karel; Podlaha, Josef

    2011-01-01

    The Nuclear Research Institute Rez plc (NRI) after 55 years of activities in the nuclear field produced some environmental liabilities that shall be remedied. There are three areas of remediation: (1) decommissioning of old obsolete facilities (e.g. decay tanks, RAW treatment technology, special sewage system), (2) processing of RAW from operation and dismantling of nuclear facilities, and (3) elimination of spent fuel from research nuclear reactors operated by the NRI. The goal is to remedy the environmental liabilities and eliminate the potential negative impact on the environment. Remediation of the environmental liabilities started in 2003 and will be finished in 2014. The character of the environmental liabilities is very specific and requires special remediation procedures. Special technologies are being developed with assistance of external subcontractors. The NRI has gained many experiences in the field of RAW management and decommissioning of nuclear facilities and will use its facilities, experienced staff and all relevant data needed for the successful realization of the remediation. The most significant items of environmental liabilities are described in the paper together with information about the history, the current state, the progress, and the future activities in the field of remediation of environmental liabilities in the NRI. (author)

  17. Research and development of pyrochemical technologies for ADTT systems in NRI Rez plc

    Uhlir, J.

    1999-01-01

    The activities within the Czech national Partitioning and Transmutation program are oriented mainly toward the following areas: (i) ADS flowsheeting working out a proposal for a suitable technological flowsheet for treating spent fuel into a form fitted for transmutation reactor, including separation procedures before transmutation (Front-end) and separation processes after passage of fuel through the transmutor (Back-end). (ii) Technological research into the uranium component separation from spent fuel by the Fluoride Volatility Method semi-pilot-plant technological research based on the application of experience from spent fuel fluoride reprocessing. (iii) Laboratory research into electro-separation methods for the separation of fission products, plutonium and minor actinides from the fluoride melt. Selection of a suitable matrix composition of fluoride melts based on studies of their physicochemical properties and design of laboratory electro-separation facility. (iv) Development of materials and equipment for molten fluoride salts based ADS technologies, i.e. construction materials development, research into the corrosion resistance and development of equipment for molten fluoride salts technologies. The NRI Rez plc cooperates in this area with the SKODA Nuclear Machinery company

  18. Synthesis of FBD-based PLC design from NuSCR formal specification

    Yoo, Junbeom; Cha, Sungdeok; Kim, Chang Hwoi; Song, Duck Yong

    2005-01-01

    NuSCR is a formal specification language to document requirements for real-time embedded software with nuclear engineering applications in mind. Domain experts actively participated in selecting how to best represent various aspects. It uses tabular notations to specify required computations and automata to document state- or time-dependent behavior. As programmable logic controllers (PLCs) are widely used to implement real-time embedded software, synthesis of PLC code from a formal specification is desirable if transformation rules can be rigorously defined. In addition to improved productivity, results of safety analysis performed on requirements remain valid. In this paper, we demonstrate how NuSCR specification can be translated into semantically equivalent function block diagram (FBD) code. The process, except the initial phase where user provides information on missing or implicit details, is automated. Since executable code can be automatically generated using CASE tools from FBD, much of software development is automated. Proposed technique is currently being used in developing reactor protection system (RPS) for nuclear power plants in Korea, and experience to date has been positive. We demonstrate the proposed approach using the fixed set-point rising trip which is one of the most complex trip logics included in the RPS

  19. TRPV1 and PLC Participate in Histamine H4 Receptor-Induced Itch.

    Jian, Tunyu; Yang, Niuniu; Yang, Yan; Zhu, Chan; Yuan, Xiaolin; Yu, Guang; Wang, Changming; Wang, Zhongli; Shi, Hao; Tang, Min; He, Qian; Lan, Lei; Wu, Guanyi; Tang, Zongxiang

    2016-01-01

    Histamine H4 receptor has been confirmed to play a role in evoking peripheral pruritus. However, the ionic and intracellular signaling mechanism of activation of H4 receptor on the dorsal root ganglion (DRG) neurons is still unknown. By using cell culture and calcium imaging, we studied the underlying mechanism of activation of H4 receptor on the DRG neuron. Immepip dihydrobromide (immepip)-a histamine H4 receptor special agonist under cutaneous injection-obviously induced itch behavior of mice. Immepip-induced scratching behavior could be blocked by TRPV1 antagonist AMG9810 and PLC pathway inhibitor U73122. Application of immepip (8.3-50 μM) could also induce a dose-dependent increase in intracellular Ca(2+) ([Ca(2+)]i) of DRG neurons. We found that 77.8% of the immepip-sensitized DRG neurons respond to the TRPV1 selective agonist capsaicin. U73122 could inhibit immepip-induced Ca(2+) responses. In addition, immepip-induced [Ca(2+)]i increase could be blocked by ruthenium red, capsazepine, and AMG9810; however it could not be blocked by TRPA1 antagonist HC-030031. These results indicate that TRPV1 but not TRPA1 is the important ion channel to induce the DRG neurons' responses in the downstream signaling pathway of histamine H4 receptor and suggest that TRPV1 may be involved in the mechanism of histamine-induced itch response by H4 receptor activation.

  20. Pengaruh Problem-Based Learning terhadap Hasil Belajar ditinjau dari Motivasi Belajar PLC di SMK

    Bekti Wulandari

    2013-06-01

    Full Text Available Penelitian ini bertujuan untuk mengetahui: (1 perbedaan hasil belajar siswa pada mata pelajaran pemrograman sistem kendali PLC antara siswa yang diajar dengan metode PBL dengan siswa yang diajar dengan metode demonstrasi, (2 pengaruh interaksi antara metode PBL dan metode demonstrasi dengan motivasi belajar terhadap hasil belajar siswa, (3 perbedaan hasil belajar siswa antara siswa yang diajar dengan metode PBL dengan yang diajar dengan metode demonstrasi ditinjau dari motivasi belajar. Penelitian ini merupakan penelitian eksperimen semu dengan desain faktorial yang dilakukan dengan memberikan perlakuan metode pembelajaran. Analisis data dalam penelitian ini  menggunakan uji-t dan ANAVA dengan program SPSS 16. Hasil penelitian menunjukkan bahwa: (1 terdapat perbedaan hasil belajar antara siswa yang diajar dengan metode PBL dengan yang diajar dengan metode demonstrasi, (2 tidak terdapat pengaruh interaksi antara metode PBL dan demonstrasi dengan motivasi belajar terhadap hasil belajar, (3 terdapat perbedaan hasil belajar antara siswa yang diajar dengan metode PBL dengan yang diajar dengan metode demonstrasi ditinjau dari motivasi tinggi dan rendah. Kata kunci: metode pembelajaran, Problem-Based Learning, motivasi belajar, hasil belajar

  1. Department of Energy: monitoring and control of British Nuclear Fuels plc

    1989-01-01

    British Nuclear Fuels plc (BNFL) was set up in 1971 to take over the nuclear fuel production and reprocessing activities of the United Kingdom Atomic Energy Authority with the Department of Energy (as majority shareholder) being responsible for the monitoring and control of BNFL's activities. BNFL's activities include the production of nuclear fuel, uranium enrichment, and the transportation and reprocessing of spent fuel. Its major capital investment includes the construction of the Thermal Oxide Reprocessing Plant (THORP) due for completion in 1992. This study examined the effectiveness of the Department's arrangements for monitoring and control and for safeguarding the Government's investment in the company, the arrangements for examining BNFL's capital investment programme and the extent to which the Department's main aims have been achieved. The examination was restricted to the financial performance. The National Audit Office found evidence to suggest that BNFL's financial performance has not kept pace with the general performance level of British Industry. Future success and performance will depend on the success of the THORP plant. (U.K.)

  2. Operación de un PLC Mediante un PDA Vía ZIGBEE

    Juan Zuluaga-Botero

    2015-07-01

    Full Text Available En este artículo se muestra la parte preliminar de interconexión de un módulo ZigBee con un Asistente Digital Personal (PDA a través de la red del Sistema de telefonía Móvil Global (GSM, para aplicación futura de comunicación con un Controlador Lógico Programable (PLC. Esta aplicación permite realizar monitoreo y control del sistema, de manera remota y con dispositivos móviles siendo el alcance del proyecto de investigación. Para este proyecto inicialmente se realizan comunicaciones que permiten empalmar las tecnologías de las redes de telefonía móvil celular con la red ZigBee, haciendo una interfaz transparente para el usuario, presentando dichos resultados en este artículo. Para esto se trabaja con tramas de datos básicas a través de la red de telefonía móvil celular, mediante mensajería corta recibida por el puerto serial del Zigbee remoto, utilizando microcontroladores para el control de los módulos que conforman esta parte del sistema de comunicación, estableciendo la interfaz con el dispositivo móvil o Smartphone vía Zigbee.

  3. The Influence of Marketing Intelligence on Business Competitive Advantage (A Study of Diamond Bank Plc

    Ladipo Patric Kunle Ade

    2017-03-01

    Full Text Available This study investigates the influence of Marketing Intelligence on Business Competitive Advantage: A study of Diamond Bank Plc, Nigeria. Five objectives were identified and translated into five research questions which aptly answered by subjecting them to a test of hypotheses. A Descriptive research was used to survey 292 members of the staff of Diamond Bank in Lagos, Central Regional branches and head office. Out of which 285 responses were obtained, while 6 responses were destroyed because they were not properly filled. Also, data was collected through a self-administered questionnaire, as Pearson correlation, T-test and Regression were used to test the hypotheses statements. However, the result of the findings revealed that marketing intelligence sub-constructs such as internal records, competitor’s sales data, marketplace opportunity, competitors’ threats and competitors’ risks have significant and positive influence on business competitive advantage. Thus, it can be concluded that marketing intelligence as sensitive information has enabled the bank to successfully acquire more profit, expand the branch network all over the country, perform better than its rivals in the market and increase its business competitive advantage.

  4. TRPV1 and PLC Participate in Histamine H4 Receptor-Induced Itch

    Tunyu Jian

    2016-01-01

    Full Text Available Histamine H4 receptor has been confirmed to play a role in evoking peripheral pruritus. However, the ionic and intracellular signaling mechanism of activation of H4 receptor on the dorsal root ganglion (DRG neurons is still unknown. By using cell culture and calcium imaging, we studied the underlying mechanism of activation of H4 receptor on the DRG neuron. Immepip dihydrobromide (immepip—a histamine H4 receptor special agonist under cutaneous injection—obviously induced itch behavior of mice. Immepip-induced scratching behavior could be blocked by TRPV1 antagonist AMG9810 and PLC pathway inhibitor U73122. Application of immepip (8.3–50 μM could also induce a dose-dependent increase in intracellular Ca2+ (Ca2+i of DRG neurons. We found that 77.8% of the immepip-sensitized DRG neurons respond to the TRPV1 selective agonist capsaicin. U73122 could inhibit immepip-induced Ca2+ responses. In addition, immepip-induced Ca2+i increase could be blocked by ruthenium red, capsazepine, and AMG9810; however it could not be blocked by TRPA1 antagonist HC-030031. These results indicate that TRPV1 but not TRPA1 is the important ion channel to induce the DRG neurons’ responses in the downstream signaling pathway of histamine H4 receptor and suggest that TRPV1 may be involved in the mechanism of histamine-induced itch response by H4 receptor activation.

  5. The energy carrier hydrogen

    Anon.

    1992-01-01

    The potential of hydrogen to be used as a clean fuel for the production of heat and power, as well as for the propulsion of aeroplanes and vehicles, is described, in particular for Germany. First, attention is paid to the application of hydrogen as a basic material for the (petro)chemical industry, as an indirect energy source for (petro)chemical processes, and as a direct energy source for several purposes. Than the importance of hydrogen as an energy carrier in a large-scale application of renewable energy sources is discussed. Next an overview is given of new and old hydrogen production techniques from fossil fuels, biomass, or the electrolysis of water. Energetic applications of hydrogen in the transportation sector and the production of electric power and heat are mentioned. Brief descriptions are given of techniques to store hydrogen safely. Finally attention is paid to hydrogen research in Germany. Two hydrogen projects, in which Germany participates, are briefly dealt with: the Euro-Quebec project (production of hydrogen by means of hydropower), and the HYSOLAR project (hydrogen production by means of solar energy). 18 figs., 1 tab., 7 refs

  6. Histamine acting on H1 receptor promotes inhibition of proliferation via PLC, RAC, and JNK-dependent pathways

    Notcovich, Cintia; Diez, Federico; Tubio, Maria Rosario; Baldi, Alberto; Kazanietz, Marcelo G.; Davio, Carlos; Shayo, Carina

    2010-01-01

    It is well established that histamine modulates cell proliferation through the activation of the histamine H1 receptor (H1R), a G protein-coupled receptor (GPCR) that is known to couple to phospholipase C (PLC) activation via Gq. In the present study, we aimed to determine whether H1R activation modulates Rho GTPases, well-known effectors of Gq/G 11 -coupled receptors, and whether such modulation influences cell proliferation. Experiments were carried out in CHO cells stably expressing H1R (CHO-H1R). By using pull-down assays, we found that both histamine and a selective H1R agonist activated Rac and RhoA in a time- and dose-dependent manner without significant changes in the activation of Cdc42. Histamine response was abolished by the H1R antagonist mepyramine, RGS2 and the PLC inhibitor U73122, suggesting that Rac and RhoA activation is mediated by H1R via Gq coupling to PLC stimulation. Histamine caused a marked activation of serum response factor activity via the H1R, as determined with a serum-responsive element (SRE) luciferase reporter, and this response was inhibited by RhoA inactivation with C3 toxin. Histamine also caused a significant activation of JNK which was inhibited by expression of the Rac-GAP β2-chimaerin. On the other hand, H1R-induced ERK1/2 activation was inhibited by U73122 but not affected by C3 or β2-chimaerin, suggesting that ERK1/2 activation was dependent on PLC and independent of RhoA or Rac. [ 3 H]-Thymidine incorporation assays showed that both histamine and the H1R agonist inhibited cell proliferation in a dose-dependent manner and that the effect was independent of RhoA but partially dependent on JNK and Rac. Our results reveal that functional coupling of the H1R to Gq-PLC leads to the activation of RhoA and Rac small GTPases and suggest distinct roles for Rho GTPases in the control of cell proliferation by histamine.

  7. LIQUIFIED NATURAL GAS (LNG) CARRIERS

    Daniel Posavec; Katarina Simon; Matija Malnar

    2010-01-01

    Modern liquefied natural gas carriers are double-bottom ships classified according to the type of LNG tank. The tanks are specially designed to store natural gas cooled to -161°C, the boiling point of methane. Since LNG is highly flammable, special care must be taken when designing and operating the ship. The development of LNG carriers has begun in the middle of the twentieth century. LNG carrier storage space has gradually grown to the current maximum of 260000 m3. There are more than 300 L...

  8. Impact of carriers in oral absorption

    Gram, Luise Kvisgaard; Rist, Gerda Marie; Lennernäs, Hans

    2009-01-01

    Carriers may mediate the permeation across enterocytes for drug substances being organic anions. Carrier mediated permeation for the organic anions estrone-3-sulfate (ES) and glipizide across Caco-2 cells were investigated kinetically, and interactions on involved carriers evaluated. Initial...

  9. 7 CFR 35.4 - Carrier.

    2010-01-01

    ... AND PLUMS Definitions § 35.4 Carrier. Carrier means any common or private carrier, including, but not being limited to, trucks, rail, airplanes, vessels, tramp or chartered steamers, whether carrying for...

  10. Research of Control System and Fault Diagnosis of the Sound-absorbing Board Production Line

    Yanjun Xiao

    2014-08-01

    Full Text Available Programmable Logic Controller is the core of the control system of the sound- absorbing board production line and the design of fault diagnosis is an essential modules in the sound- absorbing board production line. The article discourses the application of PLC in the control system of the production line, and designs the methods of grading treatment and prevention of troubles, which makes use of PLC’S logic functions. The method has good expansibility, and has good guidance to the fault diagnosis in other automation equipments.

  11. System of institutional radioactive waste management in the Nuclear Research Institute Rez plc

    Podlaha, J.; Burian, P.

    2005-01-01

    The Nuclear Research Institute Rez plc (NRI) is a leading institution in the area of nuclear Research and Development in the Czech Republic. The NRI has had a dominant position in the nuclear programme since it was established in 1955 as a state-owned research organization and it has developed to its current status. In December 1992 the NRI has been transformed into a joint-stock company. The NRI's activity encompasses nuclear physics, chemistry, nuclear power, experiments at the research reactor and many other topics. Main issues addressed in the NRI in the past decades were concentrated on research, development and services provided to the nuclear power plants operating WWER reactors, development of chemical technologies for fuel cycle and irradiation services to research and development in the industrial sector, agriculture, food processing and medicine. At present the research activities are mainly targeted to assist the State Office for Nuclear Safety -the nuclear safety regulating body, power plant operator and nuclear facilities contractors. Significant attention is also paid to the use of nuclear technology outside the nuclear power sector, providing a wide range of services to industry , medicine and the preparation of radiopharmaceuticals. NRI operates two research nuclear reactors and another facilities such as a hot cell facility , research laboratories, technology for radioactive waste (RAW) management, 60 Co irradiators, an electron accelerator, etc. In this paper the Centre of RAW management, system of RAW management, facilities for RAW management as well as decontamination and decommissioning activities of the NRI are presented. The NRI provides complex services in the area of RAW management and has gained many experience and full qualification not only in this area but also in the area of decontamination and decommissioning and spent fuel management. The NRI guarantees safe RAW and spent fuel management. (authors)

  12. Motor carrier evaluation program plan

    Portsmouth, J.H.; Maxwell, J.E.; Boness, G.O.; Rice, L.E.

    1991-04-01

    The US Department of Energy (DOE) Transportation Management Program (TMP) has established a program to assist the DOE field offices and their contractors in evaluating the motor carriers used to transport DOE-owned hazardous and radioactive materials. This program was initiated to provide the DOE field offices with the tools necessary to help ensure, during this period of motor carrier deregulation, that only highly qualified carriers transport radioactive and hazardous commodities for the DOE. This program will assist DOE in maintaining their excellent performance record in the safe transportation of hazardous commodities. The program was also developed in response to public concern surrounding the transportation of hazardous materials. Representatives of other federal agencies, states, and tribal governments, as well as the news media, have expressed concern about the selection and qualification of carriers engaged in the transportation of Highway Route-Controlled Quantities (HRCQ) and Truckload (TL) quantities of radioactive material for the DOE. 8 refs

  13. Solute carrier transporters: Pharmacogenomics research ...

    Aghogho

    2010-12-27

    Dec 27, 2010 ... This paper reviews the solute carrier transporters and highlights the fact that there is much to be learnt from .... transporters, drug targets, effect or proteins and meta- ... basolateral or apical plasma membrane of polarized cells,.

  14. 76 FR 70223 - Saratoga and North Creek Railway, LLC-Operation Exemption-Tahawus Line

    2011-11-10

    ... Newcomb. Saratoga intends to provide common carrier rail service over the subject line connecting to its...),\\1\\ a Class III rail carrier, has filed a verified notice of exemption under 49 CFR 1150.41 to... selling the line to Saratoga in the very near future.\\2\\ The rail line extends between the existing...

  15. OFDM techniques for narrow-band power line communications; OFDM-Verfahren fuer die schmalbandige Datenuebertragung im elektrischen Energieversorgungsnetz

    Hoch, Martin

    2012-07-01

    In Power Line Communications (PLC) the power distribution grid is modelled by a frequency-selective time-variant channel. Therefore, OFDM techniques are suited very well for this application since they equalize the frequency-selective behaviour in a simple fashion. For narrow-band PLC, where only little amounts of data are to be transmitted, it is advantageous to employ a non-coherent system that does not need a training sequence for channel estimation. Such type of system can be brought up with CyclicPrefix OFDM in combination with Differential Phase-Shift Keying (DPSK). In an alternative, Unique-Word OFDM, the guard interval is not filled by a cyclic prefix, but a ''unique word'', which can be deployed for channel estimation. However, there is a loss in signal-to-noise power ratio due to the special type of signal generation. This loss can be more than regained in principle, but only by applying expensive detection. Another interesting technique is Wavelet-OFDM as its transmit spectrum can be formed outstandingly because of extended transmit pulses. This implies a large overhead when short packets of data are transmitted - additionally to a training sequence, for non-coherent detection is not possible. Cyclic-Prefix OFDM and DPSK are the basis of the Physical Layers of the PLC systems ''PLC G3'' and ''PRIME''. Comparing their specifications and analyzing simulation results ''PLC G3'' turns out to be the more reliable system. In order to equalize the time-variant behaviour of the power line channel, linear equalization and Multiple Symbol Differential Detection is studied as well as algorithms to estimate the time-variant envelope. (orig.)

  16. Development of Real Time Operating System for Safety Grade PLC (POSAFE-Q) for Nuclear Power Plants

    Son, Han Seong; Hwang, Sung Jae; Lee, Young Joon; Kim, Chang Hwoi; Lee, Dong Young

    2006-01-01

    POSAFE-Q is a newly developed programmable logic controller (PLC) in order to apply to digital safety system of nuclear power plants (NPP) according to Nuclear Power Plant safety requirements. POSAFE-Q hardware and software development process, including design, review, verification and validation, and configuration control and quality assurance, satisfies the requirements imposed by 10CFR50, Appendix B. This article introduces a real time operating system pCOS, which is the core of POSAFE-Q. Section 2 describes the structure of pCOS. Section 3 describes a few important features of pCOS, which are necessary to the application for the digital safety system of NPP

  17. Design and Implementation of Control and Monitoring Systems Based on HMI-PLC for Potable Water Well

    Quezada-Quezada José Carlos

    2014-01-01

    Full Text Available This project reports on the design and implementation in a workbench of a control and monitoring system of the discharge of water of a well. Graphic User's Interfaces (GUI are designed for interaction with the operator. The Human Machine Interface (HMI was implement in proprietor software and it contemplates the rules for control and monitoring of the conditions of the system for the operator, the HMI is also interconnected a Programmable Logic Controller (PLC where the rules of protection of the process are implemented in Ladder Diagram (LD.

  18. Review of experience with plutonium exposure assessment methodologies at the nuclear fuel reprocessing site of British Nuclear Fuels plc

    Strong, R.

    1988-01-01

    British Nuclear Fuels plc and its predecessors have provided a complete range of nuclear fuel services to utilities in the UK and elsewhere for more than 30 years. Over 30,000 ton of Magnox and Oxide fuel have been reprocessed at Sellafield. During this time substantial experience has accumulated of methodologies for the assessment of exposure to actinides, mainly isotopes of plutonium. For most of the period monitoring of personnel included assessment of systemic uptake deduced from plutonium-in-urine results. The purpose of the paper is to present some conclusions of contemporary work in this area

  19. STS-55 MS1/PLC Ross and Payload Specialist Walter work in SL-D2 module

    1993-01-01

    STS-55 Mission Specialist 1 (MS1) and Payload Commander (PLC) Jerry L. Ross floats near cycle ergometer and Rack 9 Anthrorack (AR) (Human Physiology Laboratory) as German Payload Specialist 1 Ulrich Walter reviews a checklist in front of Rack 11 Experiment Rack. These experiment stations and the crewmembers are in the shirt-sleeve environment of the Spacelab Deutsche 2 (SL-D2) science module onboard the Earth-orbiting Columbia, Orbiter Vehicle (OV) 102. In the background is the SL-D2 aft end cone. Behind Ross and Walter is Rack 12 Experiment Rack with Baroreflex (BA).

  20. 75 FR 801 - Airworthiness Directives; Rolls-Royce plc RB211-Trent 500, 700, and 800 Series Turbofan Engines

    2010-01-06

    ...The FAA proposes to supersede an existing airworthiness directive (AD) for Rolls-Royce plc RB211-Trent 800 series turbofan engines. That AD currently requires replacing the fuel-to-oil heat exchanger (FOHE). This proposed AD would require replacing the FOHE on the RB211-Trent 500 and RB211-Trent 700 series turbofan engines in addition to the RB211-Trent 800 series turbofan engines. This proposed AD results from mandatory continuing airworthiness information (MCAI) issued by an aviation authority of another country to identify and correct an unsafe condition on an aviation product, and results from the risk of engine FOHE blockage. The MCAI describes the unsafe condition as:

  1. Variance in total levels of phospholipase C zeta (PLC-ζ) in human sperm may limit the applicability of quantitative immunofluorescent analysis as a diagnostic indicator of oocyte activation capability.

    Kashir, Junaid; Jones, Celine; Mounce, Ginny; Ramadan, Walaa M; Lemmon, Bernadette; Heindryckx, Bjorn; de Sutter, Petra; Parrington, John; Turner, Karen; Child, Tim; McVeigh, Enda; Coward, Kevin

    2013-01-01

    To examine whether similar levels of phospholipase C zeta (PLC-ζ) protein are present in sperm from men whose ejaculates resulted in normal oocyte activation, and to examine whether a predominant pattern of PLC-ζ localization is linked to normal oocyte activation ability. Laboratory study. University laboratory. Control subjects (men with proven oocyte activation capacity; n = 16) and men whose sperm resulted in recurrent intracytoplasmic sperm injection failure (oocyte activation deficient [OAD]; n = 5). Quantitative immunofluorescent analysis of PLC-ζ protein in human sperm. Total levels of PLC-ζ fluorescence, proportions of sperm exhibiting PLC-ζ immunoreactivity, and proportions of PLC-ζ localization patterns in sperm from control and OAD men. Sperm from control subjects presented a significantly higher proportion of sperm exhibiting PLC-ζ immunofluorescence compared with infertile men diagnosed with OAD (82.6% and 27.4%, respectively). Total levels of PLC-ζ in sperm from individual control and OAD patients exhibited significant variance, with sperm from 10 out of 16 (62.5%) exhibiting levels similar to OAD samples. Predominant PLC-ζ localization patterns varied between control and OAD samples with no predictable or consistent pattern. The results indicate that sperm from control men exhibited significant variance in total levels of PLC-ζ protein, as well as significant variance in the predominant localization pattern. Such variance may hinder the diagnostic application of quantitative PLC-ζ immunofluorescent analysis. Copyright © 2013 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  2. 29 CFR 1201.1 - Carrier.

    2010-07-01

    ... 29 Labor 4 2010-07-01 2010-07-01 false Carrier. 1201.1 Section 1201.1 Labor Regulations Relating to Labor (Continued) NATIONAL MEDIATION BOARD DEFINITIONS § 1201.1 Carrier. The term carrier includes any express company, sleeping car company, carrier by railroad, subject to the Interstate Commerce Act...

  3. Low-cost carriers fare competition effect

    Carmona Benitez, R.B.; Lodewijks, G.

    2010-01-01

    This paper examines the effects that low-cost carriers (LCC’s) produce when entering new routes operated only by full-service carriers (FSC’s) and routes operated by low-cost carriers in competition with full-service carriers. A mathematical model has been developed to determine what routes should

  4. On motions of a carrier with a mobile load along a rough inclined plane

    Bilchenko, Grigory; Bilchenko, Grigory; Bilchenko, Nataly

    2018-05-01

    A mechanical system consisting of a carrier and a load is considered. The load can move respectively to the carrier according to a predetermined motion law. The carrier can move translationally along a rectilinear trajectory on a rough inclined plane. The trajectory is the line of the greatest descent. The axis of the rectilinear channel, along which the load moves, is located in a vertical plane passing through the trajectory of the carrier. The Coulomb dry friction model is applied for simulation the forces of resistance to the motion of the carrier from the side of the underlying inclined plane. The extreme value of plane inclination angle at which the carrier is at rest, when the load is stationary, is obtained by taking into account the frictional forces of sliding at rest. Differential equations of motion of a carrier with a load moving with respect to the carrier are obtained taking into account the requirement of motion of the carrier along an inclined plane without detachment. The determining relationships are given which made it possible to classify the types of carrier motion when the channel setting angle and the plane inclination angle are related by a certain inequality. The results of computational experiments are presented.

  5. Bacterial Carriers for Glioblastoma Therapy

    Nalini Mehta

    2017-03-01

    Full Text Available Treatment of aggressive glioblastoma brain tumors is challenging, largely due to diffusion barriers preventing efficient drug dosing to tumors. To overcome these barriers, bacterial carriers that are actively motile and programmed to migrate and localize to tumor zones were designed. These carriers can induce apoptosis via hypoxia-controlled expression of a tumor suppressor protein p53 and a pro-apoptotic drug, Azurin. In a xenograft model of human glioblastoma in rats, bacterial carrier therapy conferred a significant survival benefit with 19% overall long-term survival of >100 days in treated animals relative to a median survival of 26 days in control untreated animals. Histological and proteomic analyses were performed to elucidate the safety and efficacy of these carriers, showing an absence of systemic toxicity and a restored neural environment in treated responders. In the treated non-responders, proteomic analysis revealed competing mechanisms of pro-apoptotic and drug-resistant activity. This bacterial carrier opens a versatile avenue to overcome diffusion barriers in glioblastoma by virtue of its active motility in extracellular space and can lead to tailored therapies via tumor-specific expression of tumoricidal proteins.

  6. Carrier illumination measurement of dopant lateral diffusion

    Budiarto, E.; Segovia, M.; Borden, P.; Felch, S.

    2005-01-01

    This paper describes the application of the carrier illumination technique to non-destructively measure the lateral diffusion of implanted dopants after annealing. Experiments to validate the feasibility of this method employed test structures with a constant line width of 300 nm and varying undoped spaces of 100-5000 nm. The test patterns were implanted with a p-type dopant and annealed in a 3 x 3 matrix. For each implant condition, the measured lateral diffusion was found to increase with annealing temperature, as expected. More interestingly, the lateral diffusion was not observed to relate to the vertical diffusion by a fixed proportionality factor, as is usually assumed. The ratio of lateral to vertical diffusion varies with annealing temperature, with a trend that depends on the implant condition

  7. Electromigration of carrier-free radionuclides. 15

    Roesch, F.; Reimann, T.; Buglanov, G.V.; Milanov, M.; Khalkin, V.A.; Dreyer, R.

    1988-01-01

    Using a special type of on line electromigration measurements of γ-emitting radionuclides in homogeneous electrolytes free of supporting materials the hydrolysis and the complex formations of carrier-free 249 Cf-Cf(III) with oxalate in diluted perchlorate electrolytes, T = 2.98.1(1) K, were studied. Stoichiometric hydrolysis constants of pβ 3 18.6(9) and pK 1 = 6.2(2) were calculated in μ = 0.10 electrolytes. For the formation of anionic hydrolysis products a limitation of pK 4 ≥ 13.9(3) was derived. The stoichiometric stability constants of the oxalato complexes are lgK 1 4.80(8) and lgK 2 = 3.55(11), μ = 0.01. (author)

  8. PMS2 monoallelic mutation carriers: the known unknown.

    Goodenberger, McKinsey L; Thomas, Brittany C; Riegert-Johnson, Douglas; Boland, C Richard; Plon, Sharon E; Clendenning, Mark; Win, Aung Ko; Senter, Leigha; Lipkin, Steven M; Stadler, Zsofia K; Macrae, Finlay A; Lynch, Henry T; Weitzel, Jeffrey N; de la Chapelle, Albert; Syngal, Sapna; Lynch, Patrick; Parry, Susan; Jenkins, Mark A; Gallinger, Steven; Holter, Spring; Aronson, Melyssa; Newcomb, Polly A; Burnett, Terrilea; Le Marchand, Loïc; Pichurin, Pavel; Hampel, Heather; Terdiman, Jonathan P; Lu, Karen H; Thibodeau, Stephen; Lindor, Noralane M

    2016-01-01

    Germ-line mutations in MLH1, MSH2, MSH6, and PMS2 have been shown to cause Lynch syndrome. The penetrance of the cancer and tumor spectrum has been repeatedly studied, and multiple professional societies have proposed clinical management guidelines for affected individuals. Several studies have demonstrated a reduced penetrance for monoallelic carriers of PMS2 mutations compared with the other mismatch repair (MMR) genes, but clinical management guidelines have largely proposed the same screening recommendations for all MMR gene carriers. The authors considered whether enough evidence existed to propose new screening guidelines specific to PMS2 mutation carriers with regard to age at onset and frequency of colonic screening. Published reports of PMS2 germ-line mutations were combined with unpublished cases from the authors' research registries and clinical practices, and a discussion of potential modification of cancer screening guidelines was pursued. A total of 234 monoallelic PMS2 mutation carriers from 170 families were included. Approximately 8% of those with colorectal cancer (CRC) were diagnosed before age 30, and each of these tumors presented on the left side of the colon. As it is currently unknown what causes the early onset of CRC in some families with monoallelic PMS2 germline mutations, the authors recommend against reducing cancer surveillance guidelines in families found having monoallelic PMS2 mutations in spite of the reduced penetrance.Genet Med 18 1, 13-19.

  9. 78 FR 66801 - Motor Carrier Safety Advisory Committee; Charter Renewal

    2013-11-06

    ... DEPARTMENT OF TRANSPORTATION Federal Motor Carrier Safety Administration [Docket No. FMCSA-2006-26367] Motor Carrier Safety Advisory Committee; Charter Renewal AGENCY: Federal Motor Carrier Safety... and recommendations on motor carrier safety programs and motor carrier safety regulations through a...

  10. Quality of Non-Interest Banking Services and Customers’ Satisfaction: Evidence from Jaiz Bank PLC, Kaduna, Nigeria

    Yusuf Ismaila Mustapha

    2017-02-01

    Full Text Available The dwindling levels of service quality in Nigerian financial institutions had resulted in abysmal performance of most banks and other financial institutions in the sector and this challenge has made it imperative for financial firms to be customer centered in all their operational activities. The purpose of this study is to determine the effect of service quality of non-interest bank on customers’ satisfaction using Jaiz Bank PLC, Kaduna as a case study. The study utilized convenience and snowball sampling techniques to select 147 customers who served as respondents in the study. Correlation and multiple regression analysis were employed as analytical techniques. The results show that compliance with Islamic laws is highly correlated with customer satisfaction which was followed respectively by assurance, reliability, tangibility, responsiveness and empathy dimensions. It was also discovered that the six service quality dimensions significantly influenced the satisfaction of Jaiz Bank Plc, Kaduna branch customers’. The study recommends that management of the bank should exploit and maneuver the service quality dimensions as a survival strategy for improving customers’ satisfaction in an industry characterized by intense competition and environmental dynamism.

  11. Synchronization in a PLC/VAX-based control and data-acquisition system of a nuclear-fusion experiment

    Schmidt, V.; Flor, G.; Hemming, O.N.; Luchetta, A.; Manduchi, G.; Vitturi, S.

    1990-01-01

    This paper describes the concept and implementation details of the synchronization mechanisms used in the control and data-acquisition system of the RFX (Reversed-Field Experiment) nuclear-fusion experimental device, at present under construction in Padova, Italy, within the framework of the co-ordinated nuclear-fusion research programme of the European Communities. The system employs industrial PLCs for the 'slow' control and monitoring functions, and a VAX-based CAMAC for the 'fast' functions of trigger-signal generation and data acquisition during the experiment pulses. All subsystems communicate via Ethernet, using compatible software protocols. The operational sequence of the complete system is governed by a single state machine implemented on a PLC-based supervisor system. Equivalent 'slave' state machines are implemented on all other subsystems (PLC- and VAX-based). These state machines are synchronized by means of the exchange of messages via Ethernet. This paper deals in detail with the following components which are involved in system synchronization: The Message Exchange System which implements the system-wide exchange of short messages; the Scheduler programs which implement the state machine on the various computing nodes, and which make use of the Message Exchange System. (orig.)

  12. Crystallization, optimization and preliminary X-ray characterization of a metal-dependent PI-PLC from Streptomyces antibioticus

    Jackson, Michael R.; Selby, Thomas L.

    2012-01-01

    Crystallization and diffraction analysis of a Ca 2+ -dependent PI-PLC from Streptomyces is reported. Optimization of crystals was completed using a drop-pinning technique and heavy-atom soaks to achieve high-quality diffraction to 1.23 Å. A recombinant metal-dependent phosphatidylinositol-specific phospholipase C (PI-PLC) from Streptomyces antibioticus has been crystallized by the hanging-drop method with and without heavy metals. The native crystals belonged to the orthorhombic space group P222, with unit-cell parameters a = 41.26, b = 51.86, c = 154.78 Å. The X-ray diffraction results showed significant differences in the crystal quality of samples soaked with heavy atoms. Additionally, drop pinning, which increases the surface area of the drops, was also used to improve crystal growth and quality. The combination of heavy-metal soaks and drop pinning was found to be critical for producing high-quality crystals that diffracted to 1.23 Å resolution

  13. NuSEE: an integrated environment of software specification and V and V for PLC based safety-critical systems

    Koo, Seo Ryong; Seong, Poong Hyun; Yoo, Jun Beom; Cha, Sung Deok; Youn, Cheong; Han, Hyun Chul

    2006-01-01

    As the use of digital systems becomes more prevalent, adequate techniques for software specification and analysis have become increasingly important in Nuclear Power Plant (NPP) safety-critical systems. Additionally, the importance of software Verification and Validation (V and V) based on adequate specification has received greater emphasis in view of improving software quality. For thorough V and V of safety-critical systems, V and V should be performed throughout the software lifecycle. However, systematic V and V is difficult as it involves many manual-oriented tasks. Tool support is needed in order to more conveniently perform software V and V. In response, we developed four kinds of Computer Aided Software Engineering (CASE) tools to support system specification for a formal-based analysis according to the software lifecycle. In this work, we achieved optimized integration of each tool. The toolset, NuSEE, is an integrated environment for software specification and V and V for PLC based safety-critical systems. In accordance with the software lifecycle, NuSEE consists of NuSISRT for the concept phase, NuSRS for the requirements phase, NuSDS for the design phase and NuSCM for configuration management. It is believed that after further development our integrated environment will be a unique and promising software specification and analysis toolset that will support the entire software lifecycle for the development of PLC based NPP safety-critical systems

  14. PLC SCADA systém pro řízení větrného tunelu

    Trenčan, Tomáš

    2017-01-01

    Předložená bakalářská práce se věnuje programovatelnému automatu (PLC) firmy WAGO a SCADA systémům. Skládá se ze dvou části, z teoretické části a z praktické části. V teoretické části jsou na zakladě poznatků z odborné literatury vymezeny pojmy ohledně SCADA systémů, PLC od firmy WAGO a vývojového prostředí e!COCKPIT firmy WAGO a rešerše volně dostupných SCADA systémů podporujících Modbus TCP. Na základě této rešerše byl vybrán SCADA systém pro vizualizaci dvou demonstračníc úloh v praktické ...

  15. Metodología para la implementación de controlador difuso tipo Takagi-Sugeno en PLC s7-300

    Cristian Guarnizo Lemus

    2011-12-01

    Full Text Available This paper presents a methodology for implementing fuzzy logic controllers based on a S7-300 PLC using the programming language SCL(Structured Control Language in STEP 7. We present the design of the fuzzy function, variable declarations, and the evaluation design of membership functions and rules of the fuzzy system. Since this scheme can be implemented more complex fuzzy models, such as adaptive or Autotuner. We present an application example for a discrete time simulated in the PLC using a PI fuzzy controller.

  16. Sphere-forming cell subpopulations with cancer stem cell properties in human hepatoma cell lines

    Chen Lei

    2011-06-01

    Full Text Available Abstract Background Cancer stem cells (CSCs are regarded as the cause of tumor formation and recurrence. The isolation and identification of CSCs could help to develop novel therapeutic strategies specifically targeting CSCs. Methods Human hepatoma cell lines were plated in stem cell conditioned culture system allowed for sphere forming. To evaluate the stemness characteristics of spheres, the self-renewal, proliferation, chemoresistance, tumorigenicity of the PLC/PRF/5 sphere-forming cells, and the expression levels of stem cell related proteins in the PLC/PRF/5 sphere-forming cells were assessed, comparing with the parental cells. The stem cell RT-PCR array was performed to further explore the biological properties of liver CSCs. Results The PLC/PRF/5, MHCC97H and HepG2 cells could form clonal nonadherent 3-D spheres and be serially passaged. The PLC/PRF/5 sphere-forming cells possessed a key criteria that define CSCs: persistent self-renewal, extensive proliferation, drug resistance, overexpression of liver CSCs related proteins (Oct3/4, OV6, EpCAM, CD133 and CD44. Even 500 sphere-forming cells were able to form tumors in NOD/SCID mice, and the tumor initiating capability was not decreased when spheres were passaged. Besides, downstream proteins DTX1 and Ep300 of the CSL (CBF1 in humans, Suppressor of hairless in Drosophila and LAG1 in C. elegans -independent Notch signaling pathway were highly expressed in the spheres, and a gamma-secretase inhibitor MRK003 could significantly inhibit the sphere formation ability. Conclusions Nonadherent tumor spheres from hepatoma cell lines cultured in stem cell conditioned medium possess liver CSC properties, and the CSL-independent Notch signaling pathway may play a role in liver CSCs.

  17. Hot carrier degradation in semiconductor devices

    2015-01-01

    This book provides readers with a variety of tools to address the challenges posed by hot carrier degradation, one of today’s most complicated reliability issues in semiconductor devices.  Coverage includes an explanation of carrier transport within devices and book-keeping of how they acquire energy (“become hot”), interaction of an ensemble of colder and hotter carriers with defect precursors, which eventually leads to the creation of a defect, and a description of how these defects interact with the device, degrading its performance. • Describes the intricacies of hot carrier degradation in modern semiconductor technologies; • Covers the entire hot carrier degradation phenomenon, including topics such as characterization, carrier transport, carrier-defect interaction, technological impact, circuit impact, etc.; • Enables detailed understanding of carrier transport, interaction of the carrier ensemble with the defect precursors, and an accurate assessment of how the newly created defects imp...

  18. ISS qualified thermal carrier equipment

    Deuser, Mark S.; Vellinger, John C.; Jennings, Wm. M.

    2000-01-01

    Biotechnology is undergoing a period of rapid and sustained growth, a trend which is expected to continue as the general population ages and as new medical treatments and products are conceived. As pharmaceutical and biomedical companies continue to search for improved methods of production and, for answers to basic research questions, they will seek out new avenues of research. Space processing on the International Space Station (ISS) offers such an opportunity! Space is rapidly becoming an industrial laboratory for biotechnology research and processing. Space bioprocessing offers exciting possibilities for developing new pharmaceuticals and medical treatments, which can be used to benefit mankind on Earth. It also represents a new economic frontier for the private sector. For over eight years, the thermal carrier development team at SHOT has been working with government and commercial sector scientists who are conducting microgravity experiments that require thermal control. SHOT realized several years ago that the hardware currently being used for microgravity thermal control was becoming obsolete. It is likely that the government, academic, and industrial bioscience community members could utilize SHOT's hardware as a replacement to their current microgravity thermal carrier equipment. Moreover, SHOT is aware of several international scientists interested in utilizing our space qualified thermal carrier. SHOT's economic financing concept could be extremely beneficial to the international participant, while providing a source of geographic return for their particular region. Beginning in 2000, flight qualified thermal carriers are expected to be available to both the private and government sectors. .

  19. Implementation of EPICS based Control System for Radioisotope Beam line

    Kim, Jae-Ha; Ahn, Tae-Sung; Song, Young-Gi; Kwon, Hyeok-Jung; Cho, Yong-Sub [Korea Atomic Energy Research Institute, Gyeongju (Korea, Republic of)

    2015-10-15

    Korea Mult-purpose Accelerator Complex (KOMAC) has been operating 100 MeV proton linear accelerator . For operating 100 MeV linac, various control system has been implemented such as vacuum, power supply, RCCS and etc. KOMAC is operating two beam lines so that clients can use 100 MeV proton beam for their experiment. KOMAC sends beam to beam line and target room using two dipole magnets and several quadrupole magnets. As demand for experiments and Radius Isotope using beam is increased, another beam line is under construction and RI beam line control system is need. To synchronize with KOMAC control system, RI beam line control system is based on Experimental Physics and Industrial control System (EPICS) software. The beam is transported to RI beam line to control magnet power supply and vacuum. Implementation of RI beam line control system is presented and some preliminary results are reported. The base RI beam line control system is implemented. It can control beam direction and vacuum. Comparing archived data and current data, RI beam line and control system will be improved. In the future, scroll pump and gate control system will be implemented using programmable logic controller PLC. RI beam interlock sequence will be added to KOMAC interlock system to protect linac.

  20. Analysis of interleukin (IL)-1 beta and transforming growth factor (TGF)-beta-induced signal transduction pathways in IL-2 and TGF-beta secretion and proliferation in the thymoma cell line EL4.NOB-1.

    Siese, A; Jaros, P P; Willig, A

    1999-02-01

    In the present study we investigated the interleukin (IL)-1beta and transforming growth factor-beta1 (TGF-beta1)-mediated proliferation, and production of IL-2 and TGF-beta, in the murine T-cell line, EL4.NOB-1. This cell line is resistant to TGF-beta concerning growth arrest but not autoinduction or suppression of IL-1-induced IL-2 production. When cocultured with IL-1beta, TGF-beta showed growth-promoting activity that could be antagonized by adding the phosphatidyl choline-dependent phospholipase C (PC-PLC) inhibitor, D609. Using specific enzyme inhibitors of protein kinases (PK) C and A, mitogen-activated protein kinase (MAPK), phospholipase A2 (PLA2), phosphatidylinositol-dependent (PI)-PLC and PC-PLC, we showed that IL-1beta-induced IL-2 synthesis was dependent on all investigated kinases and phospholipases, except PC-PLC. TGF-beta1 was able to inhibit IL-2 synthesis by the activation of PKA and MAPK. The same kinases are involved in TGF-beta autoinduction that is accompanied by a secretion of the active but not the latent growth factor and is antagonized by IL-1beta. Addition of the PI-PLC inhibitor, ET 18OCH3, or the PLA2 inhibitor (quinacrine) alone, resulted in secretion of latent TGF-beta and, in the case of ET 18OCH3, active TGF-beta. These data implicate a role for PI-PLC and PLA2 in the control of latency and secretion. Analysis of specific tyrosine activity and c-Fos expression showed synergistic but no antagonistic effects. These events are therefore not involved in IL- and TGF-beta-regulated IL-2 and TGF-beta production, but might participate in IL-1/TGF-beta-induced growth promotion.

  1. Coordination of motor systems of the control bars of TRIGA Mark III reactor, through the use of a PLC; Coordinacion de los sistemas motrices de las barras de control del reactor Triga Mark III, mediante el uso de un PLC

    Castro R, P. R.

    2016-07-01

    The use of programmable logic controllers (PLCs) has a wide field in the realization of automatic systems, since is sought that the form of control is easy for any user. In this work, the TRIGA Mark III reactor of Instituto Nacional de Investigaciones Nucleares (ININ) is intended to operate with a programming code in PLC for the automation of the control rods, having uniform wear according to the power required by the user. On the other hand, is proposed to develop an HMI graphical interface for communication via Ethernet, allowing supervision during the reactor operation process and greater protection of operators during reactor startup. The accuracy of the new actuators, as well as their durability, will allow a good performance of the reactor for many years to come. (Author)

  2. High Line

    Kiib, Hans

    2015-01-01

    At just over 10 meters above street level, the High Line extends three kilometers through three districts of Southwestern Manhattan in New York. It consists of simple steel construction, and previously served as an elevated rail line connection between Penn Station on 34th Street and the many....... The High Line project has been carried out as part of an open conversion strategy. The result is a remarkable urban architectural project, which works as a catalyst for the urban development of Western Manhattan. The greater project includes the restoration and reuse of many old industrial buildings...

  3. Peptide microarray profiling identifies phospholipase C gamma 1 (PLC-γ1) as a potential target for t(8;21) AML

    Mahmud, Hasan; Scherpen, Frank J. G.; Meeuwsen de Boer, Tiny; Lourens, Harm-Jan; Schoenherr, Caroline; Eder, Matthias; Scherr, Michaela; Guryev, Victor; de Bont, Eveline S.

    2017-01-01

    The t(8;21) (q22;q22) chromosomal translocation is one of the most frequent genetic alterations in acute myeloid leukemia (AML) which has a need for improved therapeutic strategies. We found PLC-γ1 as one of the highest phosphorylated peptides in t(8;21) AML samples compared to NBM or CN-AML in our

  4. 76 FR 20229 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 768-60 and Trent 772-60 Turbofan Engines

    2011-04-12

    ... inspections of the MCD. We are issuing this AD to prevent in-flight engine shutdowns caused by step aside... Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 768-60 and Trent 772-60 Turbofan Engines AGENCY... superseding an existing airworthiness directive (AD) for RR RB211-Trent 700 series turbofan engines. That AD...

  5. Novel Networked Remote Laboratory Architecture for Open Connectivity Based on PLC-OPC-LabVIEW-EJS Integration. Application in Remote Fuzzy Control and Sensors Data Acquisition.

    González, Isaías; Calderón, Antonio José; Mejías, Andrés; Andújar, José Manuel

    2016-10-31

    In this paper the design and implementation of a network for integrating Programmable Logic Controllers (PLC), the Object-Linking and Embedding for Process Control protocol (OPC) and the open-source Easy Java Simulations (EJS) package is presented. A LabVIEW interface and the Java-Internet-LabVIEW (JIL) server complete the scheme for data exchange. This configuration allows the user to remotely interact with the PLC. Such integration can be considered a novelty in scientific literature for remote control and sensor data acquisition of industrial plants. An experimental application devoted to remote laboratories is developed to demonstrate the feasibility and benefits of the proposed approach. The experiment to be conducted is the parameterization and supervision of a fuzzy controller of a DC servomotor. The graphical user interface has been developed with EJS and the fuzzy control is carried out by our own PLC. In fact, the distinctive features of the proposed novel network application are the integration of the OPC protocol to share information with the PLC and the application under control. The user can perform the tuning of the controller parameters online and observe in real time the effect on the servomotor behavior. The target group is engineering remote users, specifically in control- and automation-related tasks. The proposed architecture system is described and experimental results are presented.

  6. Novel Networked Remote Laboratory Architecture for Open Connectivity Based on PLC-OPC-LabVIEW-EJS Integration. Application in Remote Fuzzy Control and Sensors Data Acquisition

    Isaías González

    2016-10-01

    Full Text Available In this paper the design and implementation of a network for integrating Programmable Logic Controllers (PLC, the Object-Linking and Embedding for Process Control protocol (OPC and the open-source Easy Java Simulations (EJS package is presented. A LabVIEW interface and the Java-Internet-LabVIEW (JIL server complete the scheme for data exchange. This configuration allows the user to remotely interact with the PLC. Such integration can be considered a novelty in scientific literature for remote control and sensor data acquisition of industrial plants. An experimental application devoted to remote laboratories is developed to demonstrate the feasibility and benefits of the proposed approach. The experiment to be conducted is the parameterization and supervision of a fuzzy controller of a DC servomotor. The graphical user interface has been developed with EJS and the fuzzy control is carried out by our own PLC. In fact, the distinctive features of the proposed novel network application are the integration of the OPC protocol to share information with the PLC and the application under control. The user can perform the tuning of the controller parameters online and observe in real time the effect on the servomotor behavior. The target group is engineering remote users, specifically in control- and automation-related tasks. The proposed architecture system is described and experimental results are presented.

  7. The Application of S7-400H redundant PLC in I and C system for waterworks in nuclear power plant

    Pang Yuxiang

    2013-01-01

    This paper introduces Siemens S7-400H redundant PLC which is employed to implement monitor and control systems for waterworks in nuclear power plant. It focuses on the configuration and realization of the redundant system. The safety and reliability of the system is improved by using redundant CPU, network and server. (authors)

  8. 75 FR 51654 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-22B and RB211-524 Series Turbofan Engines

    2010-08-23

    ... Airworthiness Directives; Rolls-Royce plc (RR) RB211-22B and RB211-524 Series Turbofan Engines AGENCY: Federal... that air safety and the public interest require adopting the AD as proposed. Costs of Compliance Based... labor rate is $85 per work-hour. Required parts will cost about $15,000 per product. Based on these...

  9. Changes in Teachers' Beliefs and Classroom Practices Concerning Inquiry-Based Instruction Following a Year-Long RET-PLC Program

    Miranda, Rommel J.; Damico, Julie B.

    2015-01-01

    This mixed-methods study examines how engaging science teachers in a summer Research Experiences for Teachers (RET) followed by an academic-year Professional Learning Community (PLC) focused on translating teacher research experiences to inquiry-based classroom lessons might facilitate changes in their beliefs and classroom practices regarding…

  10. Compact and high-sensitivity 100-Gb/s (4 × 25 Gb/s) APD-ROSA with a LAN-WDM PLC demultiplexer.

    Yoshimatsu, Toshihide; Nada, Masahiro; Oguma, Manabu; Yokoyama, Haruki; Ohno, Tetsuichiro; Doi, Yoshiyuki; Ogawa, Ikuo; Takahashi, Hiroshi; Yoshida, Eiji

    2012-12-10

    We demonstrate an integrated 100 GbE receiver optical sub-assembly (ROSA) that incorporates a monolithic four-channel avalanche photodiode (APD) array and a planer lightwave circuit (PLC) based LAN-WDM demultiplexer. A record minimum receiver sensitivity of -20 dBm and 50-km error-free SMF transmission without an optical amplifier have been achieved.

  11. Novel Networked Remote Laboratory Architecture for Open Connectivity Based on PLC-OPC-LabVIEW-EJS Integration. Application in Remote Fuzzy Control and Sensors Data Acquisition

    González, Isaías; Calderón, Antonio José; Mejías, Andrés; Andújar, José Manuel

    2016-01-01

    In this paper the design and implementation of a network for integrating Programmable Logic Controllers (PLC), the Object-Linking and Embedding for Process Control protocol (OPC) and the open-source Easy Java Simulations (EJS) package is presented. A LabVIEW interface and the Java-Internet-LabVIEW (JIL) server complete the scheme for data exchange. This configuration allows the user to remotely interact with the PLC. Such integration can be considered a novelty in scientific literature for remote control and sensor data acquisition of industrial plants. An experimental application devoted to remote laboratories is developed to demonstrate the feasibility and benefits of the proposed approach. The experiment to be conducted is the parameterization and supervision of a fuzzy controller of a DC servomotor. The graphical user interface has been developed with EJS and the fuzzy control is carried out by our own PLC. In fact, the distinctive features of the proposed novel network application are the integration of the OPC protocol to share information with the PLC and the application under control. The user can perform the tuning of the controller parameters online and observe in real time the effect on the servomotor behavior. The target group is engineering remote users, specifically in control- and automation-related tasks. The proposed architecture system is described and experimental results are presented. PMID:27809229

  12. World lines.

    Waser Jürgen; Fuchs Raphael; Ribicic Hrvoje; Schindler Benjamin; Blöschl Günther; Gröller Eduard

    2010-01-01

    In this paper we present World Lines as a novel interactive visualization that provides complete control over multiple heterogeneous simulation runs. In many application areas decisions can only be made by exploring alternative scenarios. The goal of the suggested approach is to support users in this decision making process. In this setting the data domain is extended to a set of alternative worlds where only one outcome will actually happen. World Lines integrate simulation visualization and...

  13. Efficiency of some spectrochemical carriers

    Gomes, R.P.

    1978-01-01

    A comparative study of the efficiency of some spectrochemical carriers for the quantitative spectrographic analysis of Ag, Al, B, Bi, Cd, Cr, Cu, Fe, Mg, Mn, Mo, Ni, P, Pb, Si, Sn, V and Zn in uranium-base materials is presented. The volatility behavior of the eighteen elements is verified by means of the moving plate technique and each of the mentioned carriers. The best results are obtained with 4% In 2 O 3 , 6% AgCl and 5% NaF in a U 3 O 8 matrix. The sensitivities for some elements were extended to fractions of p.p.m. The precision, accuracy and acceptability of the method are calculated for all elements. The total error values as approximately in the range of 16-45% [pt

  14. Preventative maintenance of straddle carriers

    Si Li

    2015-04-01

    Objectives: The purpose of this industry-driven study is to model preventative maintenance (PM influences on the operational effectiveness of straddle carriers. Method: The study employs historical data consisting of 21 273 work orders covering a 27-month period. Two models are developed, both of which forecast influences of PM regimes for different types of carrier. Results: The findings of the study suggest that the reliability of the straddle fleet decreases with increased intervals of PM services. The study also finds that three factors – namely resources, number of new straddles, and the number of new lifting work centres – influence the performances of straddles. Conclusion: The authors argue that this collaborative research exercise makes a significant contribution to existing supply chain management literature, particularly in the area of operations efficiency. The study also serves as an avenue to enhance relevant management practice.

  15. Development of Real Time Operating System for Safety Grade PLC (POSAFE-Q) for Nuclear Power Plants

    Son, Han Seong [ENESYS, Taejon (Korea, Republic of); Hwang, Sung Jae [POSCON, Seoul (Korea, Republic of); Lee, Young Joon; Kim, Chang Hwoi; Lee, Dong Young [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    2006-07-01

    POSAFE-Q is a newly developed programmable logic controller (PLC) in order to apply to digital safety system of nuclear power plants (NPP) according to Nuclear Power Plant safety requirements. POSAFE-Q hardware and software development process, including design, review, verification and validation, and configuration control and quality assurance, satisfies the requirements imposed by 10CFR50, Appendix B. This article introduces a real time operating system pCOS, which is the core of POSAFE-Q. Section 2 describes the structure of pCOS. Section 3 describes a few important features of pCOS, which are necessary to the application for the digital safety system of NPP.0.

  16. A robust and stable PLC based control system for 40kJ/25kV EMM system

    Sharma, Vijay; Saroj, P.C.; Kulkarni, M.R.; Kumar, Satendra, E-mail: vijay9819420563@gmail.com [Accelerator and Pulse Power Division, Bhabha Atomic Research Centre, Mumbai (India)

    2014-07-01

    This paper describes the PLC based control system developed for a 40kJ/25kV Electro-magnetic machining (EMM) system. In EMM system large capacitor banks is charged with high voltage to store large energy and the banks is made to discharge into a coil within few milli-seconds using a triggered spark gaps. During discharge of the capacitor large surges and transients are generated in the system. The control system monitors/controls and interlocks all the units of the system for proper operation. The control system is the only subsystem which is electrically connected to all the low and high voltage subsystems. Care should be taken at the signal interfacing with the control system to protect the control system. (author)

  17. Two-mode PLC-based mode multi/demultiplexer for mode and wavelength division multiplexed transmission.

    Hanzawa, Nobutomo; Saitoh, Kuimasa; Sakamoto, Taiji; Matsui, Takashi; Tsujikawa, Kyozo; Koshiba, Masanori; Yamamoto, Fumihiko

    2013-11-04

    We proposed a PLC-based mode multi/demultiplexer (MUX/DEMUX) with an asymmetric parallel waveguide for mode division multiplexed (MDM) transmission. The mode MUX/DEMUX including a mode conversion function with an asymmetric parallel waveguide can be realized by matching the effective indices of the LP(01) and LP(11) modes of two waveguides. We report the design of a mode MUX/DEMUX that can support C-band WDM-MDM transmission. The fabricated mode MUX/DEMUX realized a low insertion loss of less than 1.3 dB and high a mode extinction ratio that exceeded 15 dB. We used the fabricated mode MUX/DEMUX to achieve a successful 2 mode x 4 wavelength x 10 Gbps transmission over a 9 km two-mode fiber with a penalty of less than 1 dB.

  18. A robust and stable PLC based control system for 40kJ/25kV EMM system

    Sharma, Vijay; Saroj, P.C.; Kulkarni, M.R.; Kumar, Satendra

    2014-01-01

    This paper describes the PLC based control system developed for a 40kJ/25kV Electro-magnetic machining (EMM) system. In EMM system large capacitor banks is charged with high voltage to store large energy and the banks is made to discharge into a coil within few milli-seconds using a triggered spark gaps. During discharge of the capacitor large surges and transients are generated in the system. The control system monitors/controls and interlocks all the units of the system for proper operation. The control system is the only subsystem which is electrically connected to all the low and high voltage subsystems. Care should be taken at the signal interfacing with the control system to protect the control system. (author)

  19. Coordination of motor systems of the control bars of TRIGA Mark III reactor, through the use of a PLC

    Castro R, P. R.

    2016-01-01

    The use of programmable logic controllers (PLCs) has a wide field in the realization of automatic systems, since is sought that the form of control is easy for any user. In this work, the TRIGA Mark III reactor of Instituto Nacional de Investigaciones Nucleares (ININ) is intended to operate with a programming code in PLC for the automation of the control rods, having uniform wear according to the power required by the user. On the other hand, is proposed to develop an HMI graphical interface for communication via Ethernet, allowing supervision during the reactor operation process and greater protection of operators during reactor startup. The accuracy of the new actuators, as well as their durability, will allow a good performance of the reactor for many years to come. (Author)

  20. Protein carriers of conjugate vaccines

    Pichichero, Michael E

    2013-01-01

    The immunogenicity of polysaccharides as human vaccines was enhanced by coupling to protein carriers. Conjugation transformed the T cell-independent polysaccharide vaccines of the past to T cell-dependent antigenic vaccines that were much more immunogenic and launched a renaissance in vaccinology. This review discusses the conjugate vaccines for prevention of infections caused by Hemophilus influenzae type b, Streptococcus pneumoniae, and Neisseria meningitidis. Specifically, the characteristics of the proteins used in the construction of the vaccines including CRM, tetanus toxoid, diphtheria toxoid, Neisseria meningitidis outer membrane complex, and Hemophilus influenzae protein D are discussed. The studies that established differences among and key features of conjugate vaccines including immunologic memory induction, reduction of nasopharyngeal colonization and herd immunity, and antibody avidity and avidity maturation are presented. Studies of dose, schedule, response to boosters, of single protein carriers with single and multiple polysaccharides, of multiple protein carriers with multiple polysaccharides and conjugate vaccines administered concurrently with other vaccines are discussed along with undesirable consequences of conjugate vaccines. The clear benefits of conjugate vaccines in improving the protective responses of the immature immune systems of young infants and the senescent immune systems of the elderly have been made clear and opened the way to development of additional vaccines using this technology for future vaccine products. PMID:23955057