Chan, Jason Y K; Leung, Iris; Navarro-Alarcon, David; Lin, Weiyang; Li, Peng; Lee, Dennis L Y; Liu, Yun-hui; Tong, Michael C F
2016-03-01
To evaluate the feasibility of a unique prototype foot-controlled robotic-enabled endoscope holder (FREE) in functional endoscopic sinus surgery. Cadaveric study. Using human cadavers, we investigated the feasibility, advantages, and disadvantages of the robotic endoscope holder in performing endoscopic sinus surgery with two hands in five cadaver heads, mimicking a single nostril three-handed technique. The FREE robot is relatively easy to use. Setup was quick, taking less than 3 minutes from docking the robot at the head of the bed to visualizing the middle meatus. The unit is also relatively small, takes up little space, and currently has four degrees of freedom. The learning curve for using the foot control was short. The use of both hands was not hindered by the presence of the endoscope in the nasal cavity. The tremor filtration also aided in the smooth movement of the endoscope, with minimal collisions. The FREE endoscope holder in an ex-vivo cadaver test corroborated the feasibility of the robotic prototype, which allows for a two-handed approach to surgery equal to a single nostril three-handed technique without the holder that may reduce operating time. Further studies will be needed to evaluate its safety profile and use in other areas of endoscopic surgery. NA. Laryngoscope, 126:566-569, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.
Bolzoni Villaret, Andrea; Doglietto, Francesco; Carobbio, Andrea; Schreiber, Alberto; Panni, Camilla; Piantoni, Enrico; Guida, Giovanni; Fontanella, Marco Maria; Nicolai, Piero; Cassinis, Riccardo
2017-09-01
Although robotics has already been applied to several surgical fields, available systems are not designed for endoscopic skull base surgery (ESBS). New conception prototypes have been recently described for ESBS. The aim of this study was to provide a systematic literature review of robotics for ESBS and describe a novel prototype developed at the University of Brescia. PubMed and Scopus databases were searched using a combination of terms, including Robotics OR Robot and Surgery OR Otolaryngology OR Skull Base OR Holder. The retrieved papers were analyzed, recording the following features: interface, tools under robotic control, force feedback, safety systems, setup time, and operative time. A novel hybrid robotic system has been developed and tested in a preclinical setting at the University of Brescia, using an industrial manipulator and readily available off-the-shelf components. A total of 11 robotic prototypes for ESBS were identified. Almost all prototypes present a difficult emergency management as one of the main limits. The Brescia Endoscope Assistant Robotic holder has proven the feasibility of an intuitive robotic movement, using the surgeon's head position: a 6 degree of freedom sensor was used and 2 light sources were added to glasses that were therefore recognized by a commercially available sensor. Robotic system prototypes designed for ESBS and reported in the literature still present significant technical limitations. Hybrid robot assistance has a huge potential and might soon be feasible in ESBS. Copyright © 2017 Elsevier Inc. All rights reserved.
A Haptic Guided Robotic System for Endoscope Positioning and Holding.
Cabuk, Burak; Ceylan, Savas; Anik, Ihsan; Tugasaygi, Mehtap; Kizir, Selcuk
2015-01-01
To determine the feasibility, advantages, and disadvantages of using a robot for holding and maneuvering the endoscope in transnasal transsphenoidal surgery. The system used in this study was a Stewart Platform based robotic system that was developed by Kocaeli University Department of Mechatronics Engineering for positioning and holding of endoscope. After the first use on an artificial head model, the system was used on six fresh postmortem bodies that were provided by the Morgue Specialization Department of the Forensic Medicine Institute (Istanbul, Turkey). The setup required for robotic system was easy, the time for registration procedure and setup of the robot takes 15 minutes. The resistance was felt on haptic arm in case of contact or friction with adjacent tissues. The adaptation process was shorter with the mouse to manipulate the endoscope. The endoscopic transsphenoidal approach was achieved with the robotic system. The endoscope was guided to the sphenoid ostium with the help of the robotic arm. This robotic system can be used in endoscopic transsphenoidal surgery as an endoscope positioner and holder. The robot is able to change the position easily with the help of an assistant and prevents tremor, and provides a better field of vision for work.
Proposal of a Budget-Friendly Camera Holder for Endoscopic Ear Surgery.
Ozturan, Orhan; Yenigun, Alper; Aksoy, Fadlullah; Ertas, Burak
2018-01-01
Endoscopic ear surgery (EES) is increasingly a preferred technique in otologic society. It offers excellent visualization of the anatomical structures directly and behind the corners with variable angled telescopes. It also provides reduced operative morbidity due to being able to perform surgical interventions with less invasive approaches. Operative preparation and setup time and cost of endoscopy system are less expensive compared with surgical microscopes. On the other hand, the main disadvantage of EES is that the surgery has to be performed with 1 single hand. It is certainly restrictive for an ear surgeon who has been operating with 2 hands under otologic microscopic views for years and certainly requires a learning period and perseverance. Holding the endoscope by a second surgeon is not executable because of insufficient surgical space.Endoscope/camera holders have been developed for those who need the comfort and convenience afforded by double-handed microscopic ear surgery. An ideal endoscope holder should be easy-to-set up, easily controlled, providing a variety of angled views, allowing the surgeon to operate with 2 hands and, budget-friendly. In this article, a commercially available 11-inch magic arm camera holder is proposed by the authors to be used in EES due to its versatile, convenient, and budget-friendly features. It allows 2-handed EES through existing technology and is affordable for surgeons looking for a low-cost and practical solution.
Eichhorn, Klaus Wolfgang; Westphal, Ralf; Rilk, Markus; Last, Carsten; Bootz, Friedrich; Wahl, Friedrich; Jakob, Mark; Send, Thorsten
2017-10-01
Having one hand occupied with the endoscope is the major disadvantage for the surgeon when it comes to functional endoscopic sinus surgery (FESS). Only the other hand is free to use the surgical instruments. Tiredness or frequent instrument changes can thus lead to shaky endoscopic images. We collected the pose data (position and orientation) of the rigid 0° endoscope and all the instruments used in 16 FESS procedures with manual endoscope guidance as well as robot-assisted endoscope guidance. In combination with the DICOM CT data, we tracked the endoscope poses and workspaces using self-developed tracking markers. All surgeries were performed once with the robot and once with the surgeon holding the endoscope. Looking at the durations required, we observed a decrease in the operating time because one surgeon doing all the procedures and so a learning curve occurred what we expected. The visual inspection of the specimens showed no damages to any of the structures outside the paranasal sinuses. Robot-assisted endoscope guidance in sinus surgery is possible. Further CT data, however, are desirable for the surgical analysis of a tracker-based navigation within the anatomic borders. Our marker-based tracking of the endoscope as well as the instruments makes an automated endoscope guidance feasible. On the subjective side, we see that RASS brings a relief for the surgeon.
Moriwaki, Yoshihiro; Otani, Jun; Okuda, Junzo; Maemoto, Ryo
2018-03-23
Both laparoscopic and endoscopic robotic surgery are widely accepted for many abdominal surgeries. However, the port site for the laparoscope cannot be easily sutured without defect, particularly in the cranial end; this can result in a port-site incisional hernia and trigger the progressive thinning and stretching of the linea alba, leading to epigastric hernia. In the present case, we encountered an epigastric hernia contiguous with an incisional scar at the port site from a previous endoscopic robotic total prostatectomy. Abdominal ultrasound and CT revealed that the width of the linea alba was 30-48 mm. Previous CT images prepared before endoscopic robotic prostatectomy had shown a thinning of the linea alba. We should be aware of the possibility of epigastric hernia after laparoscopic and endoscopic robotic surgery. In laparoscopic and endoscopic robotic surgery for a high-risk patient for epigastric hernia, we should consider additional sutures cranial to the port-site incision to prevent of an epigastric hernia. © 2018 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.
[Digital imaging and robotics in endoscopic surgery].
Go, P M
1998-05-23
The introduction of endoscopical surgery has among other things influenced technical developments in surgery. Owing to digitalisation, major progress will be made in imaging and in the sophisticated technology sometimes called robotics. Digital storage makes the results of imaging diagnostics (e.g. the results of radiological examination) suitable for transmission via video conference systems for telediagnostic purposes. The availability of digital video technique renders possible the processing, storage and retrieval of moving images as well. During endoscopical operations use may be made of a robot arm which replaces the camera man. The arm does not grow tired and provides a stable image. The surgeon himself can operate or address the arm and it can remember fixed image positions to which it can return if ordered to do so. The next step is to carry out surgical manipulations via a robot arm. This may make operations more patient-friendly. A robot arm can also have remote control: telerobotics. At the Internet site of this journal a number of supplements to this article can be found, for instance three-dimensional (3D) illustrations (which is the purpose of the 3D spectacles enclosed with this issue) and a quiz (http:@appendix.niwi. knaw.nl).
Transoral robotic surgery vs. endoscopic partial midline glossectomy for obstructive sleep apnea
Directory of Open Access Journals (Sweden)
David Folk
2017-06-01
Full Text Available Objective: To compare sleep-related outcomes in obstructive sleep apnea hypopnea syndrome (OSAHS patients following base of tongue resection via robotic surgery and endoscopic midline glossectomy. Methods: This was a retrospective study. A total of 114 robotic and 37 endoscopic midline glossectomy surgeries were performed between July 2010 and April 2015 as part of single or multilevel surgery. Patients were excluded for indications other than sleep apnea or if complete sleep studies were not obtained. Thus, 45 robotic and 16 endoscopic surgeries were included in the analysis. Results: In the robotic surgery group there were statistically significant improvements in AHI [(44.4 ± 22.6 events/hâ(14.0 ± 3.0 events/h, P < 0.001] Epworth Sleepiness Scale (12.3 ± 4.6 to 4.5 ± 2.9, P < 0.001, and O2 nadir (82.0% ± 6.1% to 85.0% ± 5.4%, P < 0.001. In the endoscopic group there were also improvements in AHI (48.7 ± 30.2 to 27.4 ± 31.9, P = 0.06, Epworth Sleepiness Scale (12.6 ± 5.5 to 8.3 ± 4.5, P = 0.08, and O2 nadir (80.2% ± 8.6% to 82.7% ± 6.5%, P = 0.4. Surgical success rate was 75.6% and 56.3% in the robotic and endoscopic groups, respectively. Greater volume of tissue removed was predictive of surgical success in the robotic cases (10.3 vs. 8.6 ml, P = 0.02. Conclusions: Both robotic surgery and endoscopic techniques for tongue base reduction improve objective measures of sleep apnea. Greater success rates may be achieved with robotic surgery compared to traditional methods. Keywords: Sleep surgery, Transoral robotic surgery, TORS, Midline glossectomy, Partial glossectomy, Posterior glossectomy
Sánchez-Margallo, Juan A; Sánchez-Margallo, Francisco M
2017-12-01
The objective of this study is to assess the surgeons' performance and ergonomics during the use of a robotic-driven needle holder in laparoscopic suturing tasks. Six right-handed laparoscopic surgeons with different levels of experience took part in this study. Participants performed a set of three different intracorporeal suturing tasks organized in ten trials during a period of five weeks. Surgeons used both conventional (Conv) and robotic (Rob) laparoscopic needle holders. Precision using the surgical needle, quality of the intracorporeal suturing performance, execution time and leakage pressure for the urethrovesical anastomosis, as well as the ergonomics of the surgeon's hand posture, were analyzed during the first, fifth and last trials. No statistically significant differences in precision and quality of suturing performance were obtained between both groups of instruments. Surgeons required more time using the robotic instrument than using the conventional needle holder to perform the urethrovesical anastomosis, but execution time was significantly reduced after training ([Formula: see text] 0.05). There were no differences in leakage pressure for the anastomoses carried out by both instruments. After training, novice surgeons significantly improved the ergonomics of the wrist ([Formula: see text] 0.05) and index finger (Conv: 36.381[Formula: see text], Rob: 30.389[Formula: see text]; p = 0.024) when using the robotic instrument compared to the conventional needle holder. Results have shown that, although both instruments offer similar technical performance, the robotic-driven instrument results in better ergonomics for the surgeon's hand posture compared to the use of a conventional laparoscopic needle holder in intracorporeal suturing.
Friedrich, D T; Sommer, F; Scheithauer, M O; Greve, J; Hoffmann, T K; Schuler, P J
2017-12-01
Objective Advanced transnasal sinus and skull base surgery remains a challenging discipline for head and neck surgeons. Restricted access and space for instrumentation can impede advanced interventions. Thus, we present the combination of an innovative robotic endoscope guidance system and a specific endoscope with adjustable viewing angle to facilitate transnasal surgery in a human cadaver model. Materials and Methods The applicability of the robotic endoscope guidance system with custom foot pedal controller was tested for advanced transnasal surgery on a fresh frozen human cadaver head. Visualization was enabled using a commercially available endoscope with adjustable viewing angle (15-90 degrees). Results Visualization and instrumentation of all paranasal sinuses, including the anterior and middle skull base, were feasible with the presented setup. Controlling the robotic endoscope guidance system was effectively precise, and the adjustable endoscope lens extended the view in the surgical field without the common change of fixed viewing angle endoscopes. Conclusion The combination of a robotic endoscope guidance system and an advanced endoscope with adjustable viewing angle enables bimanual surgery in transnasal interventions of the paranasal sinuses and the anterior skull base in a human cadaver model. The adjustable lens allows for the abandonment of fixed-angle endoscopes, saving time and resources, without reducing the quality of imaging.
Iwasa, Tsutomu; Nakadate, Ryu; Onogi, Shinya; Okamoto, Yasuharu; Arata, Jumpei; Oguri, Susumu; Ogino, Haruei; Ihara, Eikichi; Ohuchida, Kenoki; Akahoshi, Tomohiko; Ikeda, Tetsuo; Ogawa, Yoshihiro; Hashizume, Makoto
2018-04-17
Difficulties in endoscopic operations and therapeutic procedures seem to occur due to the complexity of operating the endoscope dial as well as difficulty in performing synchronized movements with both hands. We developed a prototype robotic-assisted flexible endoscope that can be controlled with a single hand in order to simplify the operation of the endoscope. The aim of this study was to confirm the operability of the robotic-assisted flexible endoscope (RAFE) by performing endoscopic submucosal dissection (ESD). Study 1: ESD was performed manually or with RAFE by an expert endoscopist in ex vivo porcine stomachs; six operations manually and six were performed with RAFE. The procedure time per unit circumferential length/area was calculated, and the results were statistically analyzed. Study 2: We evaluated how smoothly a non-endoscopist can move a RAFE compared to a manual endoscope by assessing the designated movement of the endoscope. Study 1: En bloc resection was achieved by ESD using the RAFE. The procedure time was gradually shortened with increasing experience, and the procedure time of ESD performed with the RAFE was not significantly different from that of ESD performed with a manual endoscope. Study 2: The time for the designated movement of the endoscope was significantly shorter with a RAFE than that with a manual endoscope as for a non-endoscopist. The RAFE that we developed enabled an expert endoscopist to perform the ESD procedure without any problems and allowed a non-endoscopist to control the endoscope more easily and quickly than a manual endoscope. The RAFE is expected to undergo further development.
Image-based navigation for a robotized flexible endoscope
van der Stap, N.; Slump, Cornelis H.; Broeders, Ivo Adriaan Maria Johannes; van der Heijden, Ferdinand; Luo, Xiongbiao; Reichl, Tobias; Mirota, Daniel; Soper, Timothy
2014-01-01
Robotizing flexible endoscopy enables image-based control of endoscopes. Especially during high-throughput procedures, such as a colonoscopy, navigation support algorithms could improve procedure turnaround and ergonomics for the endoscopist. In this study, we have developed and implemented a
Cabot, Jennifer C; Lee, Cho Rok; Brunaud, Laurent; Kleiman, David A; Chung, Woong Youn; Fahey, Thomas J; Zarnegar, Rasa
2012-12-01
This study presents a cost analysis of the standard cervical, gasless transaxillary endoscopic, and gasless transaxillary robotic thyroidectomy approaches based on medical costs in the United States. A retrospective review of 140 patients who underwent standard cervical, transaxillary endoscopic, or transaxillary robotic thyroidectomy at 2 tertiary centers was conducted. The cost model included operating room charges, anesthesia fee, consumables cost, equipment depreciation, and maintenance cost. Sensitivity analyses assessed individual cost variables. The mean operative times for the standard cervical, transaxillary endoscopic, and transaxillary robotic approaches were 121 ± 18.9, 185 ± 26.0, and 166 ± 29.4 minutes, respectively. The total cost for the standard cervical, transaxillary endoscopic, and transaxillary robotic approaches were $9,028 ± $891, $12,505 ± $1,222, and $13,670 ± $1,384, respectively. Transaxillary approaches were significantly more expensive than the standard cervical technique (standard cervical/transaxillary endoscopic, P cost when transaxillary endoscopic operative time decreased to 111 minutes and transaxillary robotic operative time decreased to 68 minutes. Increasing the case load did not resolve the cost difference. Transaxillary endoscopic and transaxillary robotic thyroidectomies are significantly more expensive than the standard cervical approach. Decreasing operative times reduces this cost difference. The greater expense may be prohibitive in countries with a flat reimbursement schedule. Copyright © 2012 Mosby, Inc. All rights reserved.
Next Generation Light Robotics
DEFF Research Database (Denmark)
Glückstad, Jesper
Light Robotics is a new field of research where ingredients from photonics, nanotechnology and biotechnology are put together in new ways to realize light-driven robotics at the smallest scales to solve major challenges primarily within the nanobio-domain but not limited hereto. Exploring the full...... potential of this new ‘drone-like’ light-printed, light-driven, light-actuated micro- and nano-robotics in challenging geometries requires a versatile and real-time reconfigurable light addressing that can dynamically track a plurality of tiny tools in 3D to ensure real-time continuous light...
A tele-operated mobile ultrasound scanner using a light-weight robot.
Delgorge, Cécile; Courrèges, Fabien; Al Bassit, Lama; Novales, Cyril; Rosenberger, Christophe; Smith-Guerin, Natalie; Brù, Concepció; Gilabert, Rosa; Vannoni, Maurizio; Poisson, Gérard; Vieyres, Pierre
2005-03-01
This paper presents a new tele-operated robotic chain for real-time ultrasound image acquisition and medical diagnosis. This system has been developed in the frame of the Mobile Tele-Echography Using an Ultralight Robot European Project. A light-weight six degrees-of-freedom serial robot, with a remote center of motion, has been specially designed for this application. It holds and moves a real probe on a distant patient according to the expert gesture and permits an image acquisition using a standard ultrasound device. The combination of mechanical structure choice for the robot and dedicated control law, particularly nearby the singular configuration allows a good path following and a robotized gesture accuracy. The choice of compression techniques for image transmission enables a compromise between flow and quality. These combined approaches, for robotics and image processing, enable the medical specialist to better control the remote ultrasound probe holder system and to receive stable and good quality ultrasound images to make a diagnosis via any type of communication link from terrestrial to satellite. Clinical tests have been performed since April 2003. They used both satellite or Integrated Services Digital Network lines with a theoretical bandwidth of 384 Kb/s. They showed the tele-echography system helped to identify 66% of lesions and 83% of symptomatic pathologies.
Son, Jaebum; Cho, Chang Nho; Kim, Kwang Gi; Chang, Tae Young; Jung, Hyunchul; Kim, Sung Chun; Kim, Min-Tae; Yang, Nari; Kim, Tae-Yun; Sohn, Dae Kyung
2015-06-01
Natural orifice transluminal endoscopic surgery (NOTES) is an emerging surgical technique. We aimed to design, create, and evaluate a new semi-automatic snake robot for NOTES. The snake robot employs the characteristics of both a manual endoscope and a multi-segment snake robot. This robot is inserted and retracted manually, like a classical endoscope, while its shape is controlled using embedded robot technology. The feasibility of a prototype robot for NOTES was evaluated in animals and human cadavers. The transverse stiffness and maneuverability of the snake robot appeared satisfactory. It could be advanced through the anus as far as the peritoneal cavity without any injury to adjacent organs. Preclinical tests showed that the device could navigate the peritoneal cavity. The snake robot has advantages of high transverse force and intuitive control. This new robot may be clinically superior to conventional tools for transanal NOTES.
Development and evaluation of a light-emitting diode endoscopic light source
Clancy, Neil T.; Li, Rui; Rogers, Kevin; Driscoll, Paul; Excel, Peter; Yandle, Ron; Hanna, George; Copner, Nigel; Elson, Daniel S.
2012-03-01
Light-emitting diode (LED) based endoscopic illumination devices have been shown to have several benefits over arclamp systems. LEDs are energy-efficient, small, durable, and inexpensive, however their use in endoscopy has been limited by the difficulty in efficiently coupling enough light into the endoscopic light cable. We have demonstrated a highly homogenised lightpipe LED light source that combines the light from four Luminus LEDs emitting in the red, green, blue and violet using innovative dichroics that maximise light throughput. The light source spectrally combines light from highly divergent incoherent sources that have a Lambertian intensity profile to provide illumination matched to the acceptance numerical aperture of a liquid light guide or fibre bundle. The LED light source was coupled to a standard laparoscope and performance parameters (power, luminance, colour temperature) compared to a xenon lamp. Although the total illuminance from the endoscope was lower, adjustment of the LEDs' relative intensities enabled contrast enhancement in biological tissue imaging. The LED light engine was also evaluated in a minimally invasive surgery (MIS) box trainer and in vivo during a porcine MIS procedure where it was used to generate 'narrowband' images. Future work using the violet LED could enable photodynamic diagnosis of bladder cancer.
Pose Tracking Algorithm of an Endoscopic Surgery Robot Wrist
International Nuclear Information System (INIS)
Wang, L; Yin, H L; Meng, Q
2006-01-01
In recent two decades, more and more research on the endoscopic surgery has been carried out [2]. Most of the work focuses on the development of the robot in the field of robotics and the navigation of the surgery tools based on computer graphics. But the tracking and locating of the EndoWrist is also a very important aspect. This paper deals with the the tracking algorithm of the EndoWrist's pose (position and orientation). The linear tracking of the position is handled by the Kalman Filter. The quaternion-based nonlinear orientation tracking is implemented with the Extended Kalman Filter. The most innovative point of this paper is the parameterization of the motion model of the Extended Kalman Filter
DEFF Research Database (Denmark)
Glückstad, Jesper; Palima, Darwin
Light Robotics - Structure-Mediated Nanobiophotonics covers the latest means of sculpting of both light and matter for achieving bioprobing and manipulation at the smallest scales. The synergy between photonics, nanotechnology and biotechnology spans the rapidly growing field of nanobiophotonics...
Coherent anti-Stokes Raman scattering rigid endoscope toward robot-assisted surgery.
Hirose, K; Aoki, T; Furukawa, T; Fukushima, S; Niioka, H; Deguchi, S; Hashimoto, M
2018-02-01
Label-free visualization of nerves and nervous plexuses will improve the preservation of neurological functions in nerve-sparing robot-assisted surgery. We have developed a coherent anti-Stokes Raman scattering (CARS) rigid endoscope to distinguish nerves from other tissues during surgery. The developed endoscope, which has a tube with a diameter of 12 mm and a length of 270 mm, achieved 0.91% image distortion and 8.6% non-uniformity of CARS intensity in the whole field of view (650 μm diameter). We demonstrated CARS imaging of a rat sciatic nerve and visualization of the fine structure of nerve fibers.
Light-driven robotics for nanoscopy
DEFF Research Database (Denmark)
Glückstad, Jesper; Palima, Darwin
2013-01-01
The science fiction inspired shrinking of macro-scale robotic manipulation and handling down to the micro- and nanoscale regime opens new doors for exploiting the forces and torques of light for micro- and nanoscopic probing, actuation and control. Advancing light-driven micro-robotics requires...... and matter for robotically probing at the smallest biological length scales....
Modelling of a laser-pumped light source for endoscopic surgery
Nadeau, Valerie J.; Elson, Daniel S.; Hanna, George B.; Neil, Mark A. A.
2008-09-01
A white light source, based on illumination of a yellow phosphor with a fibre-coupled blue-violet diode laser, has been designed and built for use in endoscopic surgery. This narrow light probe can be integrated into a standard laparoscope or inserted into the patient separately via a needle. We present a Monte Carlo model of light scattering and phosphorescence within the phosphor/silicone matrix at the probe tip, and measurements of the colour, intensity, and uniformity of the illumination. Images obtained under illumination with this light source are also presented, demonstrating the improvement in illumination quality over existing endoscopic light sources. This new approach to endoscopic lighting has the advantages of compact design, improved ergonomics, and more uniform illumination in comparison with current technologies.
Pose Tracking Algorithm of an Endoscopic Surgery Robot Wrist
Energy Technology Data Exchange (ETDEWEB)
Wang, L [Chinese-German Institute of Automatic Control Engineering, Tongji University (China); Yin, H L [Chinese-German Institute of Automatic Control Engineering, Tongji University (China); Meng, Q [Shanghai University of Electric Power (China)
2006-10-15
In recent two decades, more and more research on the endoscopic surgery has been carried out [2]. Most of the work focuses on the development of the robot in the field of robotics and the navigation of the surgery tools based on computer graphics. But the tracking and locating of the EndoWrist is also a very important aspect. This paper deals with the the tracking algorithm of the EndoWrist's pose (position and orientation). The linear tracking of the position is handled by the Kalman Filter. The quaternion-based nonlinear orientation tracking is implemented with the Extended Kalman Filter. The most innovative point of this paper is the parameterization of the motion model of the Extended Kalman Filter.
DEFF Research Database (Denmark)
Glückstad, Jesper; Palima, Darwin; Villangca, Mark Jayson
2016-01-01
As celebrated by the Nobel Prize 2014 in Chemistry light-based technologies can now overcome the diffraction barrier for imaging with nanoscopic resolution by so-called super-resolution microscopy1. However, interactive investigations coupled with advanced imaging modalities at these small scale ...... research discipline that could potentially be able to offer the full packet needed for true "active nanoscopy" by use of so-called light-driven micro-robotics or Light Robotics in short....
Light Robotics: Aiming towards all-optical nano-robotics
DEFF Research Database (Denmark)
Glückstad, Jesper; Palima, Darwin; Bañas, Andrew
2017-01-01
potential of this new ‘drone-like’ light-printed, light-driven, light-actuated micro- and nanorobotics in challenging geometries requires a versatile and real-time reconfigurable light addressing that can dynamically track a plurality of tiny tools in 3D to ensure real-time continuous light delivery......Light Robotics is a new field of research where ingredients from photonics, nanotechnology and biotechnology are put together in new ways to realize light-driven robotics at the smallest scales to solve major challenges primarily within the nanobio-domain but not limited hereto. Exploring the full...... on the fly. Our latest developments in this new and exciting research area will be reviewed....
Light robotics: aiming towards all-optical nano-robotics
Glückstad, Jesper; Palima, Darwin; Banas, Andrew
2017-04-01
Light Robotics is a new field of research where ingredients from photonics, nanotechnology and biotechnology are put together in new ways to realize light-driven robotics at the smallest scales to solve major challenges primarily within the nanobio-domain but not limited hereto. Exploring the full potential of this new `drone-like' light-printed, light-driven, light-actuated micro- and nanorobotics in challenging geometries requires a versatile and real-time reconfigurable light addressing that can dynamically track a plurality of tiny tools in 3D to ensure real-time continuous light-delivery on the fly. Our latest developments in this new and exciting research area will be reviewed.
Klibansky, David; Rothstein, Richard I
2012-09-01
The increasing complexity of intralumenal and emerging translumenal endoscopic procedures has created an opportunity to apply robotics in endoscopy. Computer-assisted or direct-drive robotic technology allows the triangulation of flexible tools through telemanipulation. The creation of new flexible operative platforms, along with other emerging technology such as nanobots and steerable capsules, can be transformational for endoscopic procedures. In this review, we cover some background information on the use of robotics in surgery and endoscopy, and review the emerging literature on platforms, capsules, and mini-robotic units. The development of techniques in advanced intralumenal endoscopy (endoscopic mucosal resection and endoscopic submucosal dissection) and translumenal endoscopic procedures (NOTES) has generated a number of novel platforms, flexible tools, and devices that can apply robotic principles to endoscopy. The development of a fully flexible endoscopic surgical toolkit will enable increasingly advanced procedures to be performed through natural orifices. The application of platforms and new flexible tools to the areas of advanced endoscopy and NOTES heralds the opportunity to employ useful robotic technology. Following the examples of the utility of robotics from the field of laparoscopic surgery, we can anticipate the emerging role of robotic technology in endoscopy.
Kahramangil, Bora; Mohsin, Khuzema; Alzahrani, Hassan; Bu Ali, Daniah; Tausif, Syed; Kang, Sang-Wook; Kandil, Emad; Berber, Eren
2017-12-01
Numerous new approaches have been described over the years to improve the cosmetic outcomes of thyroid surgery. Transoral approach is a new technique that aims to achieve superior cosmetic outcomes by concealing the incision in the oral cavity. Transoral thyroidectomy through vestibular approach was performed in two institutions on cadaveric models. Procedure was performed endoscopically in one institution, while the robotic technique was utilized at the other. Transoral thyroidectomy was successfully performed at both institutions with robotic and endoscopic techniques. All vital structures were identified and preserved. Transoral thyroidectomy has been performed in animal and cadaveric models, as well as in some clinical studies. Our initial experience indicates the feasibility of this approach. More clinical studies are required to elucidate its full utility.
Evaluation of the effect of a laparoscopic robotized needle holder on ergonomics and skills.
Bensignor, Thierry; Morel, Guillaume; Reversat, David; Fuks, David; Gayet, Brice
2016-02-01
Laparoscopy generates technical and ergonomics difficulties due to limited degrees of freedom (DOF) of forceps. To reduce this limitation, a new 5-mm robotized needle holder with two intracorporeal DOF, Jaimy(®), has been developed. The aim of this study was to evaluate its effects on ergonomics and skills. Fourteen surgeons including eight senior and six residents were crossover randomized and stratified based on experience. Three suturing tasks were performed with both Jaimy(®) and a classic needle holder (NH): task 1: Peg-Board; task 2: hexagonal suture; task 3: frontal suture. Postural ergonomics of the dominant arm were evaluated with an ergonomics score (RULA score) thanks to motion capture, and muscular ergonomics with electromyography of six muscular groups (flexor and extensor carpis, biceps, triceps, deltoid, trapeze). Performance outcomes are a quantitative and qualitative score, and skills outcomes are the measurement of the number of movements and the path length travelled by the instrument. The RULA score showed a statistically improved posture with Jaimy(®) (p < 0.001). The cumulative muscular workload (CMW) of four muscles was not different. However, the CMW was in favor of the NH for the flexor carpi ulnaris (p < 0.001) and the triceps (p = 0.027). The number of movements was not different (p = 0.39) although the path length was shorter with Jaimy(®) (p = 0.012). The score for task 1 was in favor of the NH (p = 0.006) with a higher quantity score. Task 2 score was not different (p = 0.086): The quality part of the score was in favor of Jaimy(®) (p = 0.009) and the quantity part was higher with the NH (p = 0.04). The score for task 3 was higher with Jaimy(®) (p = 0.001). This study suggests that the use of a robotized needle holder improves both posture and the quality of laparoscopic sutures.
Potential Applications of Light Robotics in Nanomedicine
DEFF Research Database (Denmark)
Glückstad, Jesper
We have recently pioneered a new generation of 3D micro-printed light robotic structures with multi-functional biophotonics capabilities. The uniqueness of this light robotic approach is that even if a micro-biologist aims at exploring e.g. cell biology at nanoscopic scales, the main support...... of each micro-robotic structure can be 3D printed to have a size and shape that allows convenient laser manipulation in full 3D – even using relatively modest numerical aperture optics. An optical robot is typically equipped with a number of 3D printed "track-balls" that allow for real-time 3D light...... manipulation with six-degrees-of-freedom. This creates a drone-like functionality where each light-driven robot can be e.g. joystick-controlled and provide the user a feeling of stretching his/her hands directly into and interacting with the biologic micro-environment. The light-guided robots can thus act...
Light robotics: a new field of research
DEFF Research Database (Denmark)
Engay, Einstom; Chouliara, Manto; Bañas, Andrew
2018-01-01
After years of working on light-driven trapping and manipulation, we can see that a confluence of developments is now ripe for the emergence of a new area that can contribute to nanobiophotonics - Light Robotics - which combines advances in microfabrication and optical micromanipulation together...... with intelligent control ideas from robotics, wavefront engineering and information optics. In the Summer 2017 we are publishing a 482 pages edited Elsevier book volume covering the fundamental aspects needed for Light Robotics including optical trapping systems, microfabrication and microassembly as well...... as underlying theoretical principles and experimental illustrations for optimizing optical forces and torques for Light Robotics...
Towards All-optical Light Robotics
DEFF Research Database (Denmark)
Glückstad, Jesper
In the Programmable Phase Optics (PPO) group at DTU Fotonik we pioneered the new and emerging research area of so-called Light Robotics including the new and disruptive 3D-printed micro-tools coined Wave-guided Optical Waveguides that can be real-time optically manipulated and “remote-controlled”......In the Programmable Phase Optics (PPO) group at DTU Fotonik we pioneered the new and emerging research area of so-called Light Robotics including the new and disruptive 3D-printed micro-tools coined Wave-guided Optical Waveguides that can be real-time optically manipulated and “remote......-controlled” in a volume with six-degrees-of-freedom. To be exploring the full potential of this new drone-like 3D light robotics approach in challenging microscopic geometries requires a versatile and real-time reconfigurable light coupling that can dynamically track a plurality of “light robots” in 3D to ensure...
Isaac-Lowry, Oran Jacob; Okamoto, Steele; Pedram, Sahba Aghajani; Woo, Russell; Berkelman, Peter
2017-12-01
To date a variety of teleoperated surgical robotic systems have been developed to improve a surgeon's ability to perform demanding single-port procedures. However typical large systems are bulky, expensive, and afford limited angular motion, while smaller designs suffer complications arising from limited motion range, speed, and force generation. This work was to develop and validate a simple, compact, low cost single site teleoperated laparoendoscopic surgical robotic system, with demonstrated capability to carry out basic surgical procedures. This system builds upon previous work done at the University of Hawaii at Manoa and includes instrument and endoscope manipulators as well as compact articulated instruments designed to overcome single incision geometry complications. A robotic endoscope holder was used for the base, with an added support frame for teleoperated manipulators and instruments fabricated mostly from 3D printed parts. Kinematics and control methods were formulated for the novel manipulator configuration. Trajectory following results from an optical motion tracker and sample task performance results are presented. Results indicate that the system has successfully met the goal of basic surgical functionality while minimizing physical size, complexity, and cost. Copyright © 2017 John Wiley & Sons, Ltd.
Nano-biophotonics explored by Light Robotics
DEFF Research Database (Denmark)
Glückstad, Jesper; Villangca, Mark Jayson; Palima, Darwin
for harnessing most of the functionalities required to develop the fascinating concept of true so-‐called Light Robotics. We foresee that it will soon become possible to equip 3D laser-printed robotic micro-‐structures with multi functional biophotonics nanoprobes or nanotips fabricated with true nanoscopic...... resolution. The uniqueness of such an approach is that even if a micro biologist aims at exploring e.g. cell biology at nanoscopic scales, the main support of each laser-‐robotic structure can be 3D printed to have a size and shape that allows convenient laser manipulation in full 3D– even using relatively...... modest numerical aperture optics. An optical robot is typically equipped with a number of 3D printed "trackballs" that allow for real-‐time 3D light manipulation with six-‐degrees-‐of-‐freedom. This creates a drone-‐like functionality where each light-‐driven robot can be e.g. joystick...
The latest Light Robotics breakthroughs - Postdeadline
DEFF Research Database (Denmark)
Glückstad, Jesper; Palima, Darwin; Bañas, Andrew
Contemporary nanoscopy provides functionalities, not only for observing life science on the smallest scales but also for actively reaching into and manipulating at subcellular levels. This post-deadline contribution describes the latest generation of 3D-printed micro-tools for enabling light-acti......-activated robotics on sub-diffraction scales: Light Robotics....
Transmission electron microscope sample holder with optical features
Milas, Mirko [Port Jefferson, NY; Zhu, Yimei [Stony Brook, NY; Rameau, Jonathan David [Coram, NY
2012-03-27
A sample holder for holding a sample to be observed for research purposes, particularly in a transmission electron microscope (TEM), generally includes an external alignment part for directing a light beam in a predetermined beam direction, a sample holder body in optical communication with the external alignment part and a sample support member disposed at a distal end of the sample holder body opposite the external alignment part for holding a sample to be analyzed. The sample holder body defines an internal conduit for the light beam and the sample support member includes a light beam positioner for directing the light beam between the sample holder body and the sample held by the sample support member.
Towards a compact and precise sample holder for macromolecular crystallography.
Papp, Gergely; Rossi, Christopher; Janocha, Robert; Sorez, Clement; Lopez-Marrero, Marcos; Astruc, Anthony; McCarthy, Andrew; Belrhali, Hassan; Bowler, Matthew W; Cipriani, Florent
2017-10-01
Most of the sample holders currently used in macromolecular crystallography offer limited storage density and poor initial crystal-positioning precision upon mounting on a goniometer. This has now become a limiting factor at high-throughput beamlines, where data collection can be performed in a matter of seconds. Furthermore, this lack of precision limits the potential benefits emerging from automated harvesting systems that could provide crystal-position information which would further enhance alignment at beamlines. This situation provided the motivation for the development of a compact and precise sample holder with corresponding pucks, handling tools and robotic transfer protocols. The development process included four main phases: design, prototype manufacture, testing with a robotic sample changer and validation under real conditions on a beamline. Two sample-holder designs are proposed: NewPin and miniSPINE. They share the same robot gripper and allow the storage of 36 sample holders in uni-puck footprint-style pucks, which represents 252 samples in a dry-shipping dewar commonly used in the field. The pucks are identified with human- and machine-readable codes, as well as with radio-frequency identification (RFID) tags. NewPin offers a crystal-repositioning precision of up to 10 µm but requires a specific goniometer socket. The storage density could reach 64 samples using a special puck designed for fully robotic handling. miniSPINE is less precise but uses a goniometer mount compatible with the current SPINE standard. miniSPINE is proposed for the first implementation of the new standard, since it is easier to integrate at beamlines. An upgraded version of the SPINE sample holder with a corresponding puck named SPINEplus is also proposed in order to offer a homogenous and interoperable system. The project involved several European synchrotrons and industrial companies in the fields of consumables and sample-changer robotics. Manual handling of mini
Magnetically-driven medical robots: An analytical magnetic model for endoscopic capsules design
Li, Jing; Barjuei, Erfan Shojaei; Ciuti, Gastone; Hao, Yang; Zhang, Peisen; Menciassi, Arianna; Huang, Qiang; Dario, Paolo
2018-04-01
Magnetic-based approaches are highly promising to provide innovative solutions for the design of medical devices for diagnostic and therapeutic procedures, such as in the endoluminal districts. Due to the intrinsic magnetic properties (no current needed) and the high strength-to-size ratio compared with electromagnetic solutions, permanent magnets are usually embedded in medical devices. In this paper, a set of analytical formulas have been derived to model the magnetic forces and torques which are exerted by an arbitrary external magnetic field on a permanent magnetic source embedded in a medical robot. In particular, the authors modelled cylindrical permanent magnets as general solution often used and embedded in magnetically-driven medical devices. The analytical model can be applied to axially and diametrically magnetized, solid and annular cylindrical permanent magnets in the absence of the severe calculation complexity. Using a cylindrical permanent magnet as a selected solution, the model has been applied to a robotic endoscopic capsule as a pilot study in the design of magnetically-driven robots.
Phee, S J; Ho, K Y; Lomanto, D; Low, S C; Huynh, V A; Kencana, A P; Yang, K; Sun, Z L; Chung, S C Sydney
2010-09-01
The lack of triangulation of standard endoscopic devices limits the degree of freedom for surgical maneuvers during natural orifice transluminal endoscopic surgery (NOTES). This study explored the feasibility of adapting an intuitively controlled master and slave transluminal endoscopic robot (MASTER) the authors developed to facilitate wedge hepatic resection in NOTES. The MASTER consists of a master controller, a telesurgical workstation, and a slave manipulator that holds two end-effectors: a grasper, and a monopolar electrocautery hook. The master controller is attached to the wrist and fingers of the operator and connected to the manipulator by electrical and wire cables. Movements of the operator are detected and converted into control signals driving the slave manipulator via a tendon-sheath power transmission mechanism allowing nine degrees of freedom. Using this system, wedge hepatic resection was performed through the transgastric route on two female pigs under general anesthesia. Entry into the peritoneal cavity was via a 10-mm incision made on the anterior wall of the stomach by the electrocautery hook. Wedge hepatic resection was performed using the robotic grasper and hook. Hemostasis was achieved with the electrocautery hook. After the procedure, the resected liver tissue was retrieved through the mouth using the grasper. Using the MASTER, transgastric wedge hepatic resection was successfully performed on two pigs with no laparoscopic assistance. The entire procedure took 9.4 min (range, 8.5-10.2 min), with 7.1 min (range, 6-8.2 min) spent on excision of the liver tissue. The robotics-controlled device was able to grasp, retract, and excise the liver specimen successfully in the desired plane. This study demonstrated for the first time that the MASTER could effectively mitigate the technical constraints normally encountered in NOTES procedures. With it, the triangulation of surgical tools and the manipulation of tissue became easy, and wedge hepatic
Efendiev, V. U.; Alsov, S. A.; Ruzmatov, T. M.; Mikheenko, I. L.; Chernyavsky, A. M.; Malakhov, E. S.
2015-11-01
A new technology - a thoracoscopic coronary bypass grafting with the use of Da Vinci robotic system in Russia is represented by the experience of NRICP. The technology was introduced in Russia in 2011. Overall, one hundred endoscopic coronary artery bypass procedures were performed. We have compared and analyzed results of coronary artery stenting vs minimally invasive coronary artery bypass grafting. According to the results, totally endoscopic coronary artery bypass grafting has several advantages over alternative treatment strategies.
Ogiwara, Toshihiro; Goto, Tetsuya; Nagm, Alhusain; Hongo, Kazuhiro
2017-05-01
Objective The intelligent arm-support system, iArmS, which follows the surgeon's arm and automatically fixes it at an adequate position, was developed as an operation support robot. iArmS was designed to support the surgeon's forearm to prevent hand trembling and to alleviate fatigue during surgery with a microscope. In this study, the authors report on application of this robotic device to endoscopic endonasal transsphenoidal surgery (ETSS) and evaluate their initial experiences. Methods The study population consisted of 43 patients: 29 with pituitary adenoma, 3 with meningioma, 3 with Rathke's cleft cyst, 2 with craniopharyngioma, 2 with chordoma, and 4 with other conditions. All patients underwent surgery via the endonasal transsphenoidal approach using a rigid endoscope. During the nasal and sphenoid phases, iArmS was used to support the surgeon's nondominant arm, which held the endoscope. The details of the iArmS and clinical results were collected. Results iArmS followed the surgeon's arm movement automatically. It reduced the surgeon's fatigue and stabilized the surgeon's hand during ETSS. Shaking of the video image decreased due to the steadying of the surgeon's scope-holding hand with iArmS. There were no complications related to use of the device. Conclusions The intelligent armrest, iArmS, seems to be safe and effective during ETSS. iArmS is helpful for improving the precision and safety not only for microscopic neurosurgery, but also for ETSS. Ongoing advances in robotics ensure the continued evolution of neurosurgery.
Light Robotics and its potential for integrating with magnetic carriers
DEFF Research Database (Denmark)
Glückstad, Jesper
. After years of working on light-driven trapping and manipulation, we can see that a confluence of developments is now ripe for the emergence of a new area that can contribute to nanobiophotonics – Light Robotics – which combines advances in microfabrication and optical micromanipulation together...... with intelligent control ideas from robotics, wavefront engineering and computational optics. In the Summer 2017 we published a ca. 500 pages edited Elsevier book volume covering the fundamental aspects needed for Light Robotics including optical trapping systems, microfabrication and microassembly as well...... as underlying theoretical principles and experimental illustrations for optimizing optical forces and torques for Light Robotics. The Elsevier volume is presenting various new functionalities that are enabled by these new designed light-driven micro-robots in addition to various nano-biophotonics applications...
Lee, Kit-Hang; Fu, Denny K.C.; Leong, Martin C.W.; Chow, Marco; Fu, Hing-Choi; Althoefer, Kaspar; Sze, Kam Yim; Yeung, Chung-Kwong
2017-01-01
Abstract Bioinspired robotic structures comprising soft actuation units have attracted increasing research interest. Taking advantage of its inherent compliance, soft robots can assure safe interaction with external environments, provided that precise and effective manipulation could be achieved. Endoscopy is a typical application. However, previous model-based control approaches often require simplified geometric assumptions on the soft manipulator, but which could be very inaccurate in the presence of unmodeled external interaction forces. In this study, we propose a generic control framework based on nonparametric and online, as well as local, training to learn the inverse model directly, without prior knowledge of the robot's structural parameters. Detailed experimental evaluation was conducted on a soft robot prototype with control redundancy, performing trajectory tracking in dynamically constrained environments. Advanced element formulation of finite element analysis is employed to initialize the control policy, hence eliminating the need for random exploration in the robot's workspace. The proposed control framework enabled a soft fluid-driven continuum robot to follow a 3D trajectory precisely, even under dynamic external disturbance. Such enhanced control accuracy and adaptability would facilitate effective endoscopic navigation in complex and changing environments. PMID:29251567
Light Robotics: an all-optical nano- and micro-toolbox
DEFF Research Database (Denmark)
Glückstad, Jesper; Villangca, Mark Jayson; Palima, Darwin
2017-01-01
potential of this new ‘drone-like’ light-driven micro-robotics in challenging microscopic geometries requires a versatile and real-time reconfigurable light addressing that can dynamically track a plurality of tiny micro-robots in 3D to ensure continuous optimal light coupling on the fly. Our latest......Recently we proposed the concept of so-called Light Robotics including the new and disruptive 3D fabricated micro-tools coined Wave-guided Optical Waveguides that can be real-time optically manipulated and remote-controlled with a joystick in a volume with six-degrees-of-freedom. Exploring the full...
Kim, Dong-Ho; Choi, June Young; Kim, Byoung-Gook; Hwang, Jin-Young; Park, Seong-Joo; Oh, Ah-Young; Jeon, Young-Tae; Ryu, Jung-Hee
2016-01-01
Abstract Background: Robotic or endoscopic thyroidectomy using bilateral axillo-breast approach (BABA) is frequently performed for excellent cosmesis. However, postoperative pain is remained as concerns due to the extent tissue dissection and tension during the operation. Ketamine is a noncompetitive N-methyl-d-aspartate (NMDA) receptor antagonist that reduces acute postoperative pain. We evaluated the effects of intraoperative ketamine infusion on postoperative pain control and recovery profiles following BABA robotic or endoscopic thyroidectomy. Methods: Fifty-eight adult patients scheduled for BABA robotic or endoscopic thyroidectomy were randomized into a control group (n = 29) and ketamine group (n = 29). Following induction of anesthesia, patients in each group were infused with the same volume of saline or ketamine solution (1 mg/kg bolus, 60 μg/kg/h continuous infusion). Total intravenous anesthesia with propofol and remifentanil was used to induce and maintain anesthesia. Pain scores (101-point numerical rating scale, 0 = no pain, 100 = the worst imaginable pain), the consumption of rescue analgesics, and other postoperative adverse effects were assessed at 1, 6, 24, and 48 hours postoperatively. Results: Patients in the ketamine group reported lower pain scores than those in the control group at 6 hours (30 [30] vs 50 [30]; P = 0.017), 24 hours (20 [10] vs 30 [20]; P ketamine infusion during anesthesia resulted in lower postoperative pain scores following BABA robotic or endoscopic thyroidectomy, with no increase in adverse events. PMID:27930531
Endoscopic hyperspectral imaging: light guide optimization for spectral light source
Browning, Craig M.; Mayes, Samuel; Rich, Thomas C.; Leavesley, Silas J.
2018-02-01
Hyperspectral imaging (HSI) is a technology used in remote sensing, food processing and documentation recovery. Recently, this approach has been applied in the medical field to spectrally interrogate regions of interest within respective substrates. In spectral imaging, a two (spatial) dimensional image is collected, at many different (spectral) wavelengths, to sample spectral signatures from different regions and/or components within a sample. Here, we report on the use of hyperspectral imaging for endoscopic applications. Colorectal cancer is the 3rd leading cancer for incidences and deaths in the US. One factor of severity is the miss rate of precancerous/flat lesions ( 65% accuracy). Integrating HSI into colonoscopy procedures could minimize misdiagnosis and unnecessary resections. We have previously reported a working prototype light source with 16 high-powered light emitting diodes (LEDs) capable of high speed cycling and imaging. In recent testing, we have found our current prototype is limited by transmission loss ( 99%) through the multi-furcated solid light guide (lightpipe) and the desired framerate (20-30 fps) could not be achieved. Here, we report on a series of experimental and modeling studies to better optimize the lightpipe and the spectral endoscopy system as a whole. The lightpipe was experimentally evaluated using an integrating sphere and spectrometer (Ocean Optics). Modeling the lightpipe was performed using Monte Carlo optical ray tracing in TracePro (Lambda Research Corp.). Results of these optimization studies will aid in manufacturing a revised prototype with the newly designed light guide and increased sensitivity. Once the desired optical output (5-10 mW) is achieved then the HIS endoscope system will be able to be implemented without adding onto the procedure time.
Azizian, Mahdi; Khoshnam, Mahta; Najmaei, Nima; Patel, Rajni V
2014-09-01
Intra-operative imaging is widely used to provide visual feedback to a clinician when he/she performs a procedure. In visual servoing, surgical instruments and parts of tissue/body are tracked by processing the acquired images. This information is then used within a control loop to manoeuvre a robotic manipulator during a procedure. A comprehensive search of electronic databases was completed for the period 2000-2013 to provide a survey of the visual servoing applications in medical robotics. The focus is on medical applications where image-based tracking is used for closed-loop control of a robotic system. Detailed classification and comparative study of various contributions in visual servoing using endoscopic or direct visual images are presented and summarized in tables and diagrams. The main challenges in using visual servoing for medical robotic applications are identified and potential future directions are suggested. 'Supervised automation of medical robotics' is found to be a major trend in this field. Copyright © 2013 John Wiley & Sons, Ltd.
Light-driven nano-robotics for sub-diffraction probing and sensing
DEFF Research Database (Denmark)
Glückstad, Jesper; Bañas, Andrew Rafael; Palima, Darwin
On the macro-scale robotics typically uses light for carrying information for machine vision for and feedback in artificially intelligent guidance systems and monitoring. Using the miniscule momentum of light shrinking robots down to the micro- and even nano-scale regime creates opportunities......]. Therefore, a generic approach for optimizing lightmatter interaction involves the combination of optimal light-shaping techniques with the use of optimized nano-featured shapes in light-driven micro-robotics structures. In this work, we designed different three-dimensional micro-structures and fabricated...
Endoscopes with latest technology and concept.
Gotoh
2003-09-01
Endoscopic imaging systems that perform as the "eye" of the operator during endoscopic surgical procedures have developed rapidly due to various technological developments. In addition, since the most recent turn of the century robotic surgery has increased its scope through the utilization of systems such as Intuitive Surgical's da Vinci System. To optimize the imaging required for precise robotic surgery, a unique endoscope has been developed, consisting of both a two dimensional (2D) image optical system for wider observation of the entire surgical field, and a three dimensional (3D) image optical system for observation of the more precise details at the operative site. Additionally, a "near infrared radiation" endoscopic system is under development to detect the sentinel lymph node more readily. Such progress in the area of endoscopic imaging is expected to enhance the surgical procedure from both the patient's and the surgeon's point of view.
A technical review of flexible endoscopic multitasking platforms.
Yeung, Baldwin Po Man; Gourlay, Terence
2012-01-01
Further development of advanced therapeutic endoscopic techniques and natural orifice translumenal endoscopic surgery (NOTES) requires a powerful flexible endoscopic multitasking platform. Medline search was performed to identify literature relating to flexible endoscopic multitasking platform from year 2004-2011 using keywords: Flexible endoscopic multitasking platform, NOTES, Instrumentation, Endoscopic robotic surgery, and specific names of various endoscopic multitasking platforms. Key articles from articles references were reviewed. Flexible multitasking platforms can be classified as either mechanical or robotic. Purely mechanical systems include the dual channel endoscope (DCE) (Olympus), R-Scope (Olympus), the EndoSamurai (Olympus), the ANUBIScope (Karl-Storz), Incisionless Operating Platform (IOP) (USGI), and DDES system (Boston Scientific). Robotic systems include the MASTER system (Nanyang University, Singapore) and the Viacath (Hansen Medical). The DCE, the R-Scope, the EndoSamurai and the ANUBIScope have integrated visual function and instrument manipulation function. The IOP and DDES systems rely on the conventional flexible endoscope for visualization, and instrument manipulation is integrated through the use of a flexible, often lockable, multichannel access device. The advantage of the access device concept is that it allows optics and instrument dissociation. Due to the anatomical constrains of the pharynx, systems are designed to have a diameter of less than 20 mm. All systems are controlled by traction cable system actuated either by hand or by robotic machinery. In a flexible system, this method of actuation inevitably leads to significant hysteresis. This problem will be accentuated with a long endoscope such as that required in performing colonic procedures. Systems often require multiple operators. To date, the DCE, the R-Scope, the IOP, and the Viacath system have data published relating to their application in human. Alternative forms of
Is there a role for robotic totally endoscopic coronary artery bypass in patients with a colostomy?
Gibber, Marc; Lehr, Eric J; Kon, Zachary N; Wehman, P Brody; Griffith, Bartley P; Bonatti, Johannes
2014-01-01
Preoperative colostomy presents a significant risk of sternal wound complications, mediastinitis, and ostomy injury in patients requiring coronary artery bypass grafting. Less invasive procedures in coronary surgery have a potential to reduce the risk of sternal wound healing problems. Robotic totally endoscopic coronary artery bypass grafting in patients with a colostomy has not been reported. We describe a case of completely endoscopic coronary surgery using the da Vinci Si system in a patient with a transverse colostomy. Single left internal mammary artery grafting to the left anterior coronary artery was performed successfully on the beating heart. We regard this technique as the least invasive method of surgical coronary revascularization with a potential to reduce the risk of surgical site infection and mediastinitis in patients with a colostomy.
International Nuclear Information System (INIS)
Suzuki, Naoki; Hattori, Asaki; Tanoue, Kazuo; Ieiri, Satoshi; Konishi, Kozo; Tomikawa, Morimasa; Kenmotsu, Hajime; Hashizume, Makoto
2010-01-01
This report presents the development of a VR (virtual real) training system of robotic peroral operation procedure for endoscopic resection of gastric mucosa as the training is essential because the procedure differs from usual one hitherto. For VR operation space, used is reporters' sphere-filled organ model (SFM), which is deformed by and repels to, the outside force as a soft tissue rapidly in the real time. The deformation and repellence are computable. The SFM space is reconstructed to 3D of the inner environment of stomach using MRI data. The endoscope has, at the right and left side of its top, 2 arms of inner needle knife-equipped robotic forceps and is inserted perorally for operation. In VR, the forceps can grab the gastric mucosa, cut it with the knife to complete resection and carry the specimen out of the body. For the procedure training, the time required for hemostasis, bleeding volume, trace of the arms, intensity and direction of the outer force given are recorded, with which trainee's safety and degree of skill are evaluable in VR. Hydration step and clipping to close the wound are to be further added in the procedure. (T.T.)
Kim, Dong-Ho; Choi, June Young; Kim, Byoung-Gook; Hwang, Jin-Young; Park, Seong-Joo; Oh, Ah-Young; Jeon, Young-Tae; Ryu, Jung-Hee
2016-12-01
Robotic or endoscopic thyroidectomy using bilateral axillo-breast approach (BABA) is frequently performed for excellent cosmesis. However, postoperative pain is remained as concerns due to the extent tissue dissection and tension during the operation. Ketamine is a noncompetitive N-methyl-D-aspartate (NMDA) receptor antagonist that reduces acute postoperative pain. We evaluated the effects of intraoperative ketamine infusion on postoperative pain control and recovery profiles following BABA robotic or endoscopic thyroidectomy. Fifty-eight adult patients scheduled for BABA robotic or endoscopic thyroidectomy were randomized into a control group (n = 29) and ketamine group (n = 29). Following induction of anesthesia, patients in each group were infused with the same volume of saline or ketamine solution (1 mg/kg bolus, 60 μg/kg/h continuous infusion). Total intravenous anesthesia with propofol and remifentanil was used to induce and maintain anesthesia. Pain scores (101-point numerical rating scale, 0 = no pain, 100 = the worst imaginable pain), the consumption of rescue analgesics, and other postoperative adverse effects were assessed at 1, 6, 24, and 48 hours postoperatively. Patients in the ketamine group reported lower pain scores than those in the control group at 6 hours (30 [30] vs 50 [30]; P = 0.017), 24 hours (20 [10] vs 30 [20]; P ketamine infusion during anesthesia resulted in lower postoperative pain scores following BABA robotic or endoscopic thyroidectomy, with no increase in adverse events.
Light-driven micro-robotics with holographic 3D tracking
DEFF Research Database (Denmark)
Glückstad, Jesper
2016-01-01
We recently pioneered the concept of ligh-driven micro-robotics including the new and disruptive 3D-printed micro-tools coined Wave-guided Optical Waveguides that can be real-time optically trapped and “remote-controlled” in a volume with six-degrees-of-freedom. To be exploring the full potential...... of this new drone-like 3D light robotics approach in challenging microscopic geometries requires a versatile and real-time reconfigurable light coupling that can dynamically track a plurality of “light robots” in 3D to ensure continuous optimal light coupling on the fly. Our latest developments in this new...
Evaluation of robotically controlled advanced endoscopic instruments
Reilink, Rob; Kappers, Astrid M.L.; Stramigioli, Stefano; Misra, Sarthak
Background Advanced flexible endoscopes and instruments with multiple degrees of freedom enable physicians to perform challenging procedures such as the removal of large sections of mucosal tissue. However, these advanced endoscopes are difficult to control and require several physicians to
DEFF Research Database (Denmark)
Cavalca, Filippo; Hansen, Thomas Willum; Wagner, Jakob Birkedal
can be used inside an environmental TEM (ETEM) allowing specimens to be analyzed during exposure to a controlled gas atmosphere and illumination. The holder is presently being used to study a variety of photoreactive materials and structures, including photocatalysts, photonic devices and solar cells....... For example, electron holography is being used to study p-n junctions both in the presence and in the absence of light in order to assess electron beam induced charging and discharging effects during laser light exposure [3]. Here, we present results from ETEM studies of light-induced phenomena that include...
Technological advances in robotic-assisted laparoscopic surgery.
Tan, Gerald Y; Goel, Raj K; Kaouk, Jihad H; Tewari, Ashutosh K
2009-05-01
In this article, the authors describe the evolution of urologic robotic systems and the current state-of-the-art features and existing limitations of the da Vinci S HD System (Intuitive Surgical, Inc.). They then review promising innovations in scaling down the footprint of robotic platforms, the early experience with mobile miniaturized in vivo robots, advances in endoscopic navigation systems using augmented reality technologies and tracking devices, the emergence of technologies for robotic natural orifice transluminal endoscopic surgery and single-port surgery, advances in flexible robotics and haptics, the development of new virtual reality simulator training platforms compatible with the existing da Vinci system, and recent experiences with remote robotic surgery and telestration.
The Development of light-weight 2-link robot arm for high radiation area
Energy Technology Data Exchange (ETDEWEB)
Shin, Ho Cheol; Seo, Yong Chil; Jung, Kyung Min; Choi, Young Soo
2009-10-15
A light-weight 2-link robot arm which weight is less than 8kg was developed for treating the small radio-active material in the high radiation area such as nuclear power plants and NDT area. The light-weight 2-link robot arm can be attached on a small mobile robot and carry out tasks. It is a 5 DOF robot arm including a gripper
Broeders, Ivo A M J
2014-02-01
Robotic systems were introduced 15 years ago to support complex endoscopic procedures. The technology is increasingly used in gastro-intestinal surgery. In this article, literature on experimental- and clinical research is reviewed and ergonomic issues are discussed. literature review was based on Medline search using a large variety of search terms, including e.g. robot(ic), randomized, rectal, oesophageal, ergonomics. Review articles on relevant topics are discussed with preference. There is abundant evidence of supremacy in performing complex endoscopic surgery tasks when using the robot in an experimental setting. There is little high-level evidence so far on translation of these merits to clinical practice. Robotic systems may appear helpful in complex gastro-intestinal surgery. Moreover, dedicated computer based technology integrated in telepresence systems opens the way to integration of planning, diagnostics and therapy. The first high tech add-ons such as near infrared technology are under clinical evaluation. Copyright © 2014 Elsevier Ltd. All rights reserved.
Ultra light inspection robotic arm, design and modeling
International Nuclear Information System (INIS)
Voisembert, S.
2012-01-01
One of the major challenges in robotics is the improvement of inspections operations in confined and hazardous area using unmanned remote handling systems. Articulated arm are used in this case to carry some diagnostic tools for the inspection tasks. These long reach multi-link carriers should be characterized by a large workspace and reduced mass. Today, with about ten degrees of freedom and ten meters long they have reached their performance limit. Indeed, for long reach, the arm should have enough torque to carry its own weight plus the payload in cantilever mode and enough stiffness to minimize the deflection caused by the gravity. Despite the use of best materials and components, this kind of robot has reach its performance limit. Overcoming this limit needs a change in paradigm. Therefore a problem-solving, analysis and forecasting tool TRIZ (theory of inventive problem solving) is used. It leads naturally to identify the origin of the dilemma: the proper weight of the arm and so its mass under gravity. In particular, it proposes to postulate that a no-mass robot exists. An analysis of the properties of such a robot leads to the patented concept of an ultra light inflatable robot with unique and constant volume and constant diameter joints. This new object would benefit from advantages such as easy implementation, harmlessness toward its environment and so the ability to lean on it without damage. Therefore it could easily increase its range and its foreseen low-cost building would open a wide field of new applications. This thesis work, elaborates appropriate technical concepts and dimensioning methods for ultra light inflatable robots. The payload and length performances of an inflatable robot are analytically validated. Experimentations and a finite-element modeling are used for a pre-dimensioning of the joints and different modes of construction are prototyped in partnership with, specialized company in thigh-tech textile. The joints are also modeled with
Line-feature-based calibration method of structured light plane parameters for robot hand-eye system
Qi, Yuhan; Jing, Fengshui; Tan, Min
2013-03-01
For monocular-structured light vision measurement, it is essential to calibrate the structured light plane parameters in addition to the camera intrinsic parameters. A line-feature-based calibration method of structured light plane parameters for a robot hand-eye system is proposed. Structured light stripes are selected as calibrating primitive elements, and the robot moves from one calibrating position to another with constraint in order that two misaligned stripe lines are generated. The images of stripe lines could then be captured by the camera fixed at the robot's end link. During calibration, the equations of two stripe lines in the camera coordinate system are calculated, and then the structured light plane could be determined. As the robot's motion may affect the effectiveness of calibration, so the robot's motion constraints are analyzed. A calibration experiment and two vision measurement experiments are implemented, and the results reveal that the calibration accuracy can meet the precision requirement of robot thick plate welding. Finally, analysis and discussion are provided to illustrate that the method has a high efficiency fit for industrial in-situ calibration.
... with this type of surgery give it some advantages over standard endoscopic techniques. The surgeon can make ... Elsevier Saunders; 2015:chap 87. Muller CL, Fried GM. Emerging technology in surgery: Informatics, electronics, robotics. In: ...
Knife - Holders in Ancient Egyptian Tombs (Religious and Artistic Study
Directory of Open Access Journals (Sweden)
dr.Rasha Omran
2015-01-01
Full Text Available Studying ancient Egyptian tombs have long been an important source of information regarding many aspects of Egyptian religion. Walls of New Kingdom tombs are often decorated with plenty of painted religious scenes. While they were primarily private structures containing images selected by the person who expected to be housed there for eternity, the funerary monuments also reflect religious beliefs. While numerous researches focused on many of the religious scenes depicted on the walls of ancient Egyptian tombs, no one focused on the knife - holders' scenes. Hence, the current study focused on knife - holders scenes depicted on the walls of both royal and private tombs dating back to the New Kingdom at Thebes. The current study was undertaken to shed light on the meaning and the function of knife in Ancient Egypt. To study the role of the knife-holders in Ancient Egypt. To spot light on the actions and behaviors and locations of the knife-holders in Ancient Egyptian civilization. To spot light on the representations of the knife-holders on the walls of the ancient Egyptians tombs in the Valley of the Kings and Valley of the Queens as well as the private tombs at western Thebes. To focus on the shapes and positions of the Knife-holders in Ancient Egypt. To explain the difference between Knife - Holders and Demons. To achieve the objectives of the study, the required data were collected from periodicals, references presenting Knife Holders scenes. Preserving the scenes of knife - holders on the walls of the royal tombs in the Valley of the Kings and Valley of the Queens dating back to the New Kingdom as well as the private tombs at western Thebes that contributed to the interpretation of all the data gathered from literature. The preliminary results indicated that the term (Knife-Holders is an expression which indicates to tomb-guardians, demons or minor divinities. These minor deities were subordinate to the major gods and goddesses. They
Pointing with a One-Eyed Cursor for Supervised Training in Minimally Invasive Robotic Surgery
DEFF Research Database (Denmark)
Kibsgaard, Martin; Kraus, Martin
2016-01-01
Pointing in the endoscopic view of a surgical robot is a natural and effcient way for instructors to communicate with trainees in robot-assisted minimally invasive surgery. However, pointing in a stereo-endoscopic view can be limited by problems such as video delay, double vision, arm fatigue......-day training units in robot- assisted minimally invasive surgery on anaesthetised pigs....
DEFF Research Database (Denmark)
Villangca, Mark Jayson; Palima, Darwin; Banas, Andrew Rafael
2017-01-01
-assisted surgery imbibes surgeons with superhuman abilities and gives the expression “surgical precision” a whole new meaning. Still in its infancy, much remains to be done to improve human-robot collaboration both in realizing robots that can operate safely with humans and in training personnel that can work......Conventional robotics provides machines and robots that can replace and surpass human performance in repetitive, difficult, and even dangerous tasks at industrial assembly lines, hazardous environments, or even at remote planets. A new class of robotic systems no longer aims to replace humans...... with so-called automatons but, rather, to create robots that can work alongside human operators. These new robots are intended to collaborate with humans—extending their abilities—from assisting workers on the factory floor to rehabilitating patients in their homes. In medical robotics, robot...
EXPERIENCE WITH ROBOTIC LUMЕNIS CO LASER IN ENDOSCOPIC LARYNGEAL SURGERY
Directory of Open Access Journals (Sweden)
E. N. Novozhilova
2014-01-01
Full Text Available 2 The paper describes the first experience in using robotic CO laser at the Department of Head and Neck Tumors, Moscow City Cancer Hospital Sixty-Two. With advances in endoscopic techniques and anesthesiology, there have been new possibilities of usingdirect (rigid larygoscopy in conjunction with laser systems.The Lumеnis laser assembly consists of three interconnected components: a videocamera, an operating microscope, and directly CO laser. It includes a computer system that sets a program to perform an operation.The heart of the laser system is a scanning Digital Acu Blade micromanipulator. This unique assembly makes itpossible to control the area and depth of incision, to cut intricate shapes in relation to the surface anatomy, and to precisely control ablation and hemostasis. The effect of tissue carbonization during surgery is minimal at the expense of the physical characteristics and different modes of radiation. It is noted that this system allows organ-sparing treatment in cancer patients and their prompt rehabilitation after surgical interventions.
Robotic thyroidectomy versus endoscopic thyroidectomy: a meta-analysis
Directory of Open Access Journals (Sweden)
Lin Shuang
2012-11-01
Full Text Available Abstract Background To conduct a meta-analysis to determine the relative merits of robotic thyroidectomy (RT and endoscopic thyroidectomy (ET. Methods A literature search was performed to identify comparative studies reporting peri-operative outcomes for RT and ET. Pooled odds ratios (ORs and weighted mean differences (WMDs with 95% confidence interval (95% CI were calculated using either a fixed-effects or a random-effects model. Results Six studies matched the selection criteria, which reported on 2048 subjects, of whom 978 underwent RT and 1070 underwent ET. Comparing the outcomes of RT with ET, this meta-analysis indicated that RT was associated with more complications (WMD = 1.51, 95% CI 1.18 to 1.94 and greater amount of drainage fluid (WMD = 17.10, 95% CI 5.69 to 28.51. Meanwhile, operating time (WMD = 1.50, 95% CI −39.59 to 42.58, conversion (WMD = 0.63, 95% CI 0.07 to 6.17, post-operative hospital stay (WMD = −0.05; 95% CI −0.18 to 0.08, and the number of lymph nodes harvested (WMD = 0.62, 95% CI −0.29 to 1.53 were similar for both procedures. Conclusion The results of this meta-analysis indicated that RT is associated with an increased risk of complications and a greater amount of drainage fluid. Therefore, RT does not appear to have any advantage over ET. Further studies are required to confirm these results.
Kim, Myungjoon; Lee, Chiwon; Hong, Nhayoung; Kim, Yoon Jae; Kim, Sungwan
2017-06-24
Although robotic laparoscopic surgery has various benefits when compared with conventional open surgery and minimally invasive surgery, it also has issues to overcome and one of the issues is the discontinuous surgical flow that occurs whenever control is swapped between the endoscope system and the operating robot arm system. This can lead to problems such as collision between surgical instruments, injury to patients, and increased operation time. To achieve continuous surgical operation, a wireless controllable stereo endoscope system is proposed which enables the simultaneous control of the operating robot arm system and the endoscope system. The proposed system consists of two improved novel master interfaces (iNMIs), a four-degrees of freedom (4-DOFs) endoscope control system (ECS), and a simple three-dimensional (3D) endoscope. In order to simultaneously control the proposed system and patient side manipulators of da Vinci research kit (dVRK), the iNMIs are installed to the master tool manipulators of dVRK system. The 4-DOFs ECS consists of four servo motors and employs a two-parallel link structure to provide translational and fulcrum point motion to the simple 3D endoscope. The images acquired by the endoscope undergo stereo calibration and rectification to provide a clear 3D vision to the surgeon as available in clinically used da Vinci surgical robot systems. Tests designed to verify the accuracy, data transfer time, and power consumption of the iNMIs were performed. The workspace was calculated to estimate clinical applicability and a modified peg transfer task was conducted with three novice volunteers. The iNMIs operated for 317 min and moved in accordance with the surgeon's desire with a mean latency of 5 ms. The workspace was calculated to be 20378.3 cm 3 , which exceeds the reference workspace of 549.5 cm 3 . The novice volunteers were able to successfully execute the modified peg transfer task designed to evaluate the proposed system's overall
Review of emerging surgical robotic technology.
Peters, Brian S; Armijo, Priscila R; Krause, Crystal; Choudhury, Songita A; Oleynikov, Dmitry
2018-04-01
The use of laparoscopic and robotic procedures has increased in general surgery. Minimally invasive robotic surgery has made tremendous progress in a relatively short period of time, realizing improvements for both the patient and surgeon. This has led to an increase in the use and development of robotic devices and platforms for general surgery. The purpose of this review is to explore current and emerging surgical robotic technologies in a growing and dynamic environment of research and development. This review explores medical and surgical robotic endoscopic surgery and peripheral technologies currently available or in development. The devices discussed here are specific to general surgery, including laparoscopy, colonoscopy, esophagogastroduodenoscopy, and thoracoscopy. Benefits and limitations of each technology were identified and applicable future directions were described. A number of FDA-approved devices and platforms for robotic surgery were reviewed, including the da Vinci Surgical System, Sensei X Robotic Catheter System, FreeHand 1.2, invendoscopy E200 system, Flex® Robotic System, Senhance, ARES, the Single-Port Instrument Delivery Extended Research (SPIDER), and the NeoGuide Colonoscope. Additionally, platforms were reviewed which have not yet obtained FDA approval including MiroSurge, ViaCath System, SPORT™ Surgical System, SurgiBot, Versius Robotic System, Master and Slave Transluminal Endoscopic Robot, Verb Surgical, Miniature In Vivo Robot, and the Einstein Surgical Robot. The use and demand for robotic medical and surgical platforms is increasing and new technologies are continually being developed. New technologies are increasingly implemented to improve on the capabilities of previously established systems. Future studies are needed to further evaluate the strengths and weaknesses of each robotic surgical device and platform in the operating suite.
Hand-held transendoscopic robotic manipulators: A transurethral laser prostate surgery case study.
Hendrick, Richard J; Mitchell, Christopher R; Herrell, S Duke; Webster, Robert J
2015-11-01
Natural orifice endoscopic surgery can enable incisionless approaches, but a major challenge is the lack of small and dexterous instrumentation. Surgical robots have the potential to meet this need yet often disrupt the clinical workflow. Hand-held robots that combine thin manipulators and endoscopes have the potential to address this by integrating seamlessly into the clinical workflow and enhancing dexterity. As a case study illustrating the potential of this approach, we describe a hand-held robotic system that passes two concentric tube manipulators through a 5 mm port in a rigid endoscope for transurethral laser prostate surgery. This system is intended to catalyze the use of a clinically superior, yet rarely attempted, procedure for benign prostatic hyperplasia. This paper describes system design and experiments to evaluate the surgeon's functional workspace and accuracy using the robot. Phantom and cadaver experiments demonstrate successful completion of the target procedure via prostate lobe resection.
Robotic-surgical instrument wrist pose estimation.
Fabel, Stephan; Baek, Kyungim; Berkelman, Peter
2010-01-01
The Compact Lightweight Surgery Robot from the University of Hawaii includes two teleoperated instruments and one endoscope manipulator which act in accord to perform assisted interventional medicine. The relative positions and orientations of the robotic instruments and endoscope must be known to the teleoperation system so that the directions of the instrument motions can be controlled to correspond closely to the directions of the motions of the master manipulators, as seen by the the endoscope and displayed to the surgeon. If the manipulator bases are mounted in known locations and all manipulator joint variables are known, then the necessary coordinate transformations between the master and slave manipulators can be easily computed. The versatility and ease of use of the system can be increased, however, by allowing the endoscope or instrument manipulator bases to be moved to arbitrary positions and orientations without reinitializing each manipulator or remeasuring their relative positions. The aim of this work is to find the pose of the instrument end effectors using the video image from the endoscope camera. The P3P pose estimation algorithm is used with a Levenberg-Marquardt optimization to ensure convergence. The correct transformations between the master and slave coordinate frames can then be calculated and updated when the bases of the endoscope or instrument manipulators are moved to new, unknown, positions at any time before or during surgical procedures.
[Robotic assistance in gynaecological surgery: State-of-the-art].
Monsarrat, N; Collinet, P; Narducci, F; Leblanc, E; Vinatier, D
2009-05-01
From the Automated Endoscopic System for Optimal Positioning (AESOP), a robotic arm which operates the laparoscope, to the robots Zeus and da Vinci, robotic assistance in gynaecological endoscopic surgery has continuously evolved for the last fifteen years or so. It has brought about new technical advancements: the last generation robots offer a steady three-dimensional image, improved instrument dexterity and precision, higher ergonomics and comfort for the surgeon. The da Vinci robotic system has been used without evincing any specific morbidity in various cases, notably for tubal reanastomosis, myomectomy, hysterectomy, pelvic and para-aortic lymphadenectomy or sacrocolpopexy amongst others. Robotic assistance in gynaecology is thus feasible. Like conventional laparoscopic surgery, it allows decreased blood loss and morbidity as well as shorter hospital stay, as compared to laparotomy. It might indeed allow many surgical teams to perform minimally invasive surgical procedures which they were not used to performing by laparoscopy. Randomized prospective studies are needed to define its indications more precisely. Besides, its medico-financial impact should be evaluated too.
Preclinical cadaveric study of transanal endoscopic da Vinci® surgery.
Hompes, R; Rauh, S M; Hagen, M E; Mortensen, N J
2012-08-01
Single-port platforms are increasingly being used for transanal surgery and may be associated with a shorter learning curve than transanal endoscopic microsurgery. However, these procedures remain technically challenging, and robotic technology could overcome some of the limitations and increase intraluminal manoeuvrability. An initial experimental experience with transanal endoscopic da Vinci(®) surgery (TEdS) using a glove port on human cadavers is reported. After initial dry laboratory experiments, the feasibility of TEdS and ideal set-up were further evaluated in human cadavers. For transanal access a glove port was constructed on-table by using a circular anal dilator, a standard wound retractor and a surgical glove. A da Vinci(®) Si HD system was used in combination with the glove port for transanal endoscopic resections. It was possible to perform all necessary tasks to complete a full-thickness excision and closure of the rectal wall, with cadavers in both prone and supine positions. The stable magnified view, combined with the EndoWrist(®) technology of the robotic instruments, made every task straightforward. Intraluminal manoeuvrability could be improved further by intersecting the robotic instruments. The glove port proved to be very reliable and the inherent flexibility of the glove facilitated docking of the robotic arms in a narrow confined space. Using a reliable and universally available glove port, TEdS was feasible and a preferred set-up was determined. Further clinical trials will be necessary to assess the safety and efficacy of this technique. Copyright © 2012 British Journal of Surgery Society Ltd. Published by John Wiley & Sons, Ltd.
Method for radiometric calibration of an endoscope's camera and light source
Rai, Lav; Higgins, William E.
2008-03-01
An endoscope is a commonly used instrument for performing minimally invasive visual examination of the tissues inside the body. A physician uses the endoscopic video images to identify tissue abnormalities. The images, however, are highly dependent on the optical properties of the endoscope and its orientation and location with respect to the tissue structure. The analysis of endoscopic video images is, therefore, purely subjective. Studies suggest that the fusion of endoscopic video images (providing color and texture information) with virtual endoscopic views (providing structural information) can be useful for assessing various pathologies for several applications: (1) surgical simulation, training, and pedagogy; (2) the creation of a database for pathologies; and (3) the building of patient-specific models. Such fusion requires both geometric and radiometric alignment of endoscopic video images in the texture space. Inconsistent estimates of texture/color of the tissue surface result in seams when multiple endoscopic video images are combined together. This paper (1) identifies the endoscope-dependent variables to be calibrated for objective and consistent estimation of surface texture/color and (2) presents an integrated set of methods to measure them. Results show that the calibration method can be successfully used to estimate objective color/texture values for simple planar scenes, whereas uncalibrated endoscopes performed very poorly for the same tests.
Innovations in robotic surgery.
Gettman, Matthew; Rivera, Marcelino
2016-05-01
Developments in robotic surgery have continued to advance care throughout the field of urology. The purpose of this review is to evaluate innovations in robotic surgery over the past 18 months. The release of the da Vinci Xi system heralded an improvement on the Si system with improved docking, the ability to further manipulate robotic arms without clashing, and an autofocus universal endoscope. Robotic simulation continues to evolve with improvements in simulation training design to include augmented reality in robotic surgical education. Robotic-assisted laparoendoscopic single-site surgery continues to evolve with improvements on technique that allow for tackling previously complex pathologic surgical anatomy including urologic oncology and reconstruction. Last, innovations of new surgical platforms with robotic systems to improve surgeon ergonomics and efficiency in ureteral and renal surgery are being applied in the clinical setting. Urologic surgery continues to be at the forefront of the revolution of robotic surgery with advancements in not only existing technology but also creation of entirely novel surgical systems.
Than, Trung Duc; Alici, Gursel; Harvey, Steven; Zhou, Hao; Li, Weihua
2014-07-01
Over the last decade, wireless capsule endoscope has been the tool of choice for noninvasive inspection of the gastrointestinal tract, especially in the small intestine. However, the latest clinical products have not been equipped with a sufficiently accurate localization system which makes it difficult to determine the location of intestinal abnormalities, and to apply follow-up interventions such as biopsy or drug delivery. In this paper, the authors present a novel localization method based on tracking three positron emission markers embedded inside an endoscopic capsule. Three spherical(22)Na markers with diameters of less than 1 mm are embedded in the cover of the capsule. Gamma ray detectors are arranged around a patient body to detect coincidence gamma rays emitted from the three markers. The position of each marker can then be estimated using the collected data by the authors' tracking algorithm which consists of four consecutive steps: a method to remove corrupted data, an initialization method, a clustering method based on the Fuzzy C-means clustering algorithm, and a failure prediction method. The tracking algorithm has been implemented inMATLAB utilizing simulation data generated from the Geant4 Application for Emission Tomography toolkit. The results show that this localization method can achieve real-time tracking with an average position error of less than 0.4 mm and an average orientation error of less than 2°. The authors conclude that this study has proven the feasibility and potential of the proposed technique in effectively determining the position and orientation of a robotic endoscopic capsule.
International Nuclear Information System (INIS)
Than, Trung Duc; Alici, Gursel; Zhou, Hao; Li, Weihua; Harvey, Steven
2014-01-01
Purpose: Over the last decade, wireless capsule endoscope has been the tool of choice for noninvasive inspection of the gastrointestinal tract, especially in the small intestine. However, the latest clinical products have not been equipped with a sufficiently accurate localization system which makes it difficult to determine the location of intestinal abnormalities, and to apply follow-up interventions such as biopsy or drug delivery. In this paper, the authors present a novel localization method based on tracking three positron emission markers embedded inside an endoscopic capsule. Methods: Three spherical 22 Na markers with diameters of less than 1 mm are embedded in the cover of the capsule. Gamma ray detectors are arranged around a patient body to detect coincidence gamma rays emitted from the three markers. The position of each marker can then be estimated using the collected data by the authors’ tracking algorithm which consists of four consecutive steps: a method to remove corrupted data, an initialization method, a clustering method based on the Fuzzy C-means clustering algorithm, and a failure prediction method. Results: The tracking algorithm has been implemented inMATLAB utilizing simulation data generated from the Geant4 Application for Emission Tomography toolkit. The results show that this localization method can achieve real-time tracking with an average position error of less than 0.4 mm and an average orientation error of less than 2°. Conclusions: The authors conclude that this study has proven the feasibility and potential of the proposed technique in effectively determining the position and orientation of a robotic endoscopic capsule
Broeders, Ivo Adriaan Maria Johannes; Kuipers, E.J.
2014-01-01
Abstract: Robotic systems were introduced 15 years ago to support complex endoscopic procedures. The technology is increasingly used in gastro-intestinal surgery. In this article, literature on experimental- and clinical research is reviewed and ergonomic issues are discussed. Methods: literature
Development of robot for light repairing work of nuclear power plants
International Nuclear Information System (INIS)
Katayanagi, Hiroshi; Shoji, Yoshito; Tamura, Kimiyoshi; Yamashita, Shigeru.
1990-01-01
When leakage occurs in the primary cooling system and auxiliary machinery system of nuclear reactors, in order to limit the leakage to outside to minimum, and prevent the escalation to accidents and troubles, the retightening of valve glands, the repair of leakage at piping flanges and so on become necessary. For the labor saving and the reduction of radiation exposure of workers, the development of a robot which can carry out these repair works by remote operation has been performed from 1985 to 1989. At the time of the development, the working areas in nuclear power stations were surveyed, the objects of application were narrowed down, and the development of elementary technologies and job analysis were carried out, thereafter, a robot was manufactured for trial. Subsequently, it was confirmed by using the mock-up facilities that the robot can do remote repair. The robot for light repairing works which was developed is described in this report. The functional features of the robot, the course of its development and the results of the mock-up test are reported. Hereafter, the expansion of the range of repair works and to make the robot intelligent are intended to make it into a practical robot. (K.I.)
Mamelak, Adam N; Carmichael, John; Bonert, Vivien H; Cooper, Odelia; Melmed, Shlomo
2013-09-01
The objective of this study was to evaluate outcomes of endoscopic transsphenoidal surgery using a single-surgeon technique as an alternative to the more commonly employed two-surgeon, three-hand method. Three hundred consecutive endoscopic transsphenoidal procedures performed over a 5 year period from 2006 to 2011 were reviewed. All procedures were performed via a binasal approach utilizing a single surgeon two handed technique with a pneumatic endoscope holder. Expanded enodnansal cases were excluded. Surgical technique, biochemical and surgical outcomes, and complications were analyzed. 276 patients underwent 300 consecutive surgeries with a mean follow-up period of 37 ± 22 months. Non-functioning pituitary adenoma (NFPA) was the most common pathology (n = 152), followed by growth hormone secreting tumors (n = 41) and Rathke's cleft cysts (n = 30). Initial gross total cyst drainage based on radiologic criteria was obtained in 28 cases of Rathke's cleft cyst, with 5 recurrences. For NFPA and other pathologies (n = 173) gross total resection was obtained in 137 cases, with a 92% concordance rate between observed and expected extent of resection. For functional adenoma, remission rates were 30/41 (73%) for GH-secreting, 12/12 (100%) for ACTH-secreting, and 8/17 (47%) for prolactin-secreting tumors. Post-operative complications included transient (11%) and permanent (1.4%) diabetes insipidus, hyponatremia (13%), and new anterior pituitary hormonal deficits (1.4%). CSF leak occurred in 42 cases (15%), and four patients required surgical repair. Two carotid artery injuries occurred, both early in the series. Epistaxis and other rhinological complications were noted in 10% of patients, most of which were minor and diminished as surgical experience increased. Fully endoscopic single surgeon transsphenoidal surgery utilizing a binasal approach and a pneumatic endoscope holder yields outcomes comparable to those reported with a two-surgeon method. Endoscopic outcomes
Intraoperative navigation of an optically tracked surgical robot.
Cornellà, Jordi; Elle, Ole Jakob; Ali, Wajid; Samset, Eigil
2008-01-01
This paper presents an adaptive control scheme for improving the performance of a surgical robot when it executes tasks autonomously. A commercial tracking system is used to correlate the robot with the preoperative plan as well as to correct the position of the robot when errors between the real and planned positions are detected. Due to the noisy signals provided by the tracking system, a Kalman filter is proposed to smooth the variations and to increase the stability of the system. The efficiency of the approach has been validated using rigid and flexible endoscopic tools, obtaining in both cases that the target points can be reached with an error less than 1mm. These results make the approach suitable for a range of abdominal procedures, such as autonomous repositioning of endoscopic tools or probes for percutaneous procedures.
DEFF Research Database (Denmark)
2009-01-01
An adjustable microchip holder for holding a microchip is provided having a plurality of displaceable interconnection pads for connecting the connection holes of a microchip with one or more external devices or equipment. The adjustable microchip holder can fit different sizes of microchips...
Robot-assisted general surgery.
Hazey, Jeffrey W; Melvin, W Scott
2004-06-01
With the initiation of laparoscopic techniques in general surgery, we have seen a significant expansion of minimally invasive techniques in the last 16 years. More recently, robotic-assisted laparoscopy has moved into the general surgeon's armamentarium to address some of the shortcomings of laparoscopic surgery. AESOP (Computer Motion, Goleta, CA) addressed the issue of visualization as a robotic camera holder. With the introduction of the ZEUS robotic surgical system (Computer Motion), the ability to remotely operate laparoscopic instruments became a reality. US Food and Drug Administration approval in July 2000 of the da Vinci robotic surgical system (Intuitive Surgical, Sunnyvale, CA) further defined the ability of a robotic-assist device to address limitations in laparoscopy. This includes a significant improvement in instrument dexterity, dampening of natural hand tremors, three-dimensional visualization, ergonomics, and camera stability. As experience with robotic technology increased and its applications to advanced laparoscopic procedures have become more understood, more procedures have been performed with robotic assistance. Numerous studies have shown equivalent or improved patient outcomes when robotic-assist devices are used. Initially, robotic-assisted laparoscopic cholecystectomy was deemed safe, and now robotics has been shown to be safe in foregut procedures, including Nissen fundoplication, Heller myotomy, gastric banding procedures, and Roux-en-Y gastric bypass. These techniques have been extrapolated to solid-organ procedures (splenectomy, adrenalectomy, and pancreatic surgery) as well as robotic-assisted laparoscopic colectomy. In this chapter, we review the evolution of robotic technology and its applications in general surgical procedures.
Validation of in-line surface characterization by light scattering in Robot Assisted Polishing
DEFF Research Database (Denmark)
Pilny, Lukas; Bissacco, Giuliano; De Chiffre, Leonardo
2014-01-01
The suitability of a commercial scattered light sensor for in-line characterization of fine surfaces in the roughness range Sa 1 – 30 nm generated by the Robot Assisted Polishing (RAP) was investigated and validated. A number of surfaces were generated and directly measured with the scattered light...
The SEP "robot": a valid virtual reality robotic simulator for the Da Vinci Surgical System?
van der Meijden, O A J; Broeders, I A M J; Schijven, M P
2010-04-01
The aim of the study was to determine if the concept of face and construct validity may apply to the SurgicalSim Educational Platform (SEP) "robot" simulator. The SEP robot simulator is a virtual reality (VR) simulator aiming to train users on the Da Vinci Surgical System. To determine the SEP's face validity, two questionnaires were constructed. First, a questionnaire was sent to users of the Da Vinci system (reference group) to determine a focused user-group opinion and their recommendations concerning VR-based training applications for robotic surgery. Next, clinical specialists were requested to complete a pre-tested face validity questionnaire after performing a suturing task on the SEP robot simulator. To determine the SEP's construct validity, outcome parameters of the suturing task were compared, for example, relative to participants' endoscopic experience. Correlations between endoscopic experience and outcome parameters of the performed suturing task were tested for significance. On an ordinal five-point, scale the average score for the quality of the simulator software was 3.4; for its hardware, 3.0. Over 80% agreed that it is important to train surgeons and surgical trainees to use the Da Vinci. There was a significant but marginal difference in tool tip trajectory (p = 0.050) and a nonsignificant difference in total procedure time (p = 0.138) in favor of the experienced group. In conclusion, the results of this study reflect a uniform positive opinion using VR training in robotic surgery. Concepts of face and construct validity of the SEP robotic simulator are present; however, these are not strong and need to be improved before implementation of the SEP robotic simulator in its present state for a validated training curriculum to be successful .
Marcus, Hani J; Cundy, Thomas P; Hughes-Hallett, Archie; Yang, Guang-Zhong; Darzi, Ara; Nandi, Dipankar
2014-10-01
The literature reflects a resurgence of interest in endoscopic and keyhole endoscope-assisted neurosurgical approaches as alternatives to conventional microsurgical approaches in carefully selected cases. The aim of this study was to assess the technical challenges of neuroendoscopy, and the scope for technological innovations to overcome these barriers. All full members of the Society of British Neurosurgeons (SBNS) were electronically invited to participate in an online survey. The open-ended structured survey asked three questions; firstly, whether the surgeon presently utilises or has experience with endoscopic or endoscope-assisted approaches; secondly, what they consider to be the major technical barriers to adopting such approaches; and thirdly, what technological advances they foresee improving safety and efficacy in the field. Responses were subjected to a qualitative research method of multi-rater emergent theme analysis. Three clear themes emerged: 1) surgical approach and better integration with image-guidance systems (20%), 2) intra-operative visualisation and improvements in neuroendoscopy (49%), and 3) surgical manipulation and improvements in instruments (74%). The analysis of responses to our open-ended survey revealed that although opinion was varied three major themes could be identified. Emerging technological advances such as augmented reality, high-definition stereo-endoscopy, and robotic joint-wristed instruments may help overcome the technical difficulties associated with neuroendoscopic approaches. Results of this qualitative survey provide consensus amongst the technology end-user community such that unambiguous goals and priorities may be defined. Systems integrating these advances could improve the safety and efficacy of endoscopic and endoscope-assisted neurosurgical approaches.
Asmanes, Charles
1979-01-01
A tool fixture is provided for precise pre-alignment of a radiused edge cutting tool in a tool holder relative to a fixed reference pivot point established on said holder about which the tool holder may be selectively pivoted relative to the fixture base member to change the contact point of the tool cutting edge with a workpiece while maintaining the precise same tool cutting radius relative to the reference pivot point.
Design optimization on the drive train of a light-weight robotic arm
DEFF Research Database (Denmark)
Zhou, Lelai; Bai, Shaoping; Hansen, Michael Rygaard
2011-01-01
A drive train optimization method for design of light-weight robots is proposed. Optimal selections of motors and gearboxes from a limited catalog of commercially available components are done simultaneously for all joints of a robotic arm. Characteristics of the motor and gearbox, including gear...... ratio, gear inertia, motor inertia, and gear efficiency, are considered in the drive train modeling. A co-simulation method is developed for dynamic simulation of the arm. A design example is included to demonstrate the proposed design optimization method....
Right-Arm Robotic-Aided-Therapy with the Light-Exoskeleton: A General Overview
Lugo-Villeda, Luis I.; Frisoli, Antonio; Sotgiu, Edoardo; Greco, Giovanni; Bergamasco, Massimo
Rehabilitation robotics applications and their developments have been spreading out as consequences of the actual needs in the human activities of daily living (ADL). Exoskeletons for rehabilitation are one of them, whose intrinsic characteristics are quite useful for applications where repetitive, robustness and accurate performance are a must. As a part of robotic-mediated-rehabilitation programme into the worldwide, the exoskeletons are trying to improve the ADL of disable people through the fusion of several disciplines that lets to expand the capabilities of wearing a powered robotic exoskeletal device for rehabilitation tasks. This fact deserves to present this contribution from a general scope point of view, i.e., the technologies integration and its associated knowledge. So far, the Light-Exoskeleton which is intended for human arm rehabilitation in post-stroke patients is introduced. Preliminary experimental results as well as the involved stages about the system show the capabilities of using a robotic-constrained-rehabilitation for human arm.
Design of a modified endoscope illuminator for spectral imaging of colorectal tissues
Browning, Craig M.; Mayes, Samuel; Rich, Thomas C.; Leavesley, Silas J.
2017-02-01
The gold standard for locating colonic polyps is a white light endoscope in a colonoscopy, however, polyps smaller than 5 mm can be easily missed. Modified procedures such as narrow band imaging have shown only marginal increases in detection rates. Spectral imaging is a potential solution to improve the sensitivity and specificity of colonoscopies by providing the ability to distinguish molecular fluorescence differences in tissues. The goal of this work is to implement a spectral endoscopic light source to acquire spectral image data of colorectal tissues. A beta-version endoscope light source was developed, by retrofitting a white light endoscope light source (Olympus, CLK-4) with 16 narrow band LEDs. This redesigned, beta-prototype uses high-power LEDs with a minimum output of 500 mW to provide sufficient spectral output (0.5 mW) through the endoscope. A mounting apparatus was designed to provide sufficient heat dissipation. Here, we report recent results of our tests to characterize the intensity output through the light source and endoscope to determine the flat spectral output for imaging and intensity losses through the endoscope. We also report preliminary spectral imaging data from transverse pig colon that demonstrates the ability to result in working practical spectral data. Preliminary results of this revised prototype spectral endoscope system demonstrate that there is sufficient power to allow the imaging process to continue and potentially determine spectral differences in cancerous and normal tissue from imaging ex vivo pairs. Future work will focus on building a spectral library for the colorectal region and refining the user interface the system for in vivo use.
Fernandez-Nogueras Jimenez, Francisco J; Segura Fernandez-Nogueras, Miguel; Jouma Katati, Majed; Arraez Sanchez, Miguel Ángel; Roda Murillo, Olga; Sánchez Montesinos, Indalecio
2015-01-01
The role of robotic surgery is well established in various specialties such as urology and general surgery, but not in others such as neurosurgery and otolaryngology. In the case of surgery of the skull base, it has just emerged from an experimental phase. To investigate possible applications of the da Vinci surgical robot in transoral skull base surgery, comparing it with the authors' experience using conventional endoscopic transnasal surgery in the same region. A transoral transpalatal approach to the nasopharynx and medial skull base was performed on 4 cryopreserved cadaver heads. We used the da Vinci robot, a 30° standard endoscope 12mm thick, dual camera and dual illumination, Maryland forceps on the left terminal and curved scissors on the right, both 8mm thick. Bone drilling was performed manually. For the anatomical study of this region, we used 0.5cm axial slices from a plastinated cadaver head. Various skull base structures at different depths were reached with relative ease with the robot terminals Transoral robotic surgery with the da Vinci system provides potential advantages over conventional endoscopic transnasal surgery in the surgical approach to this region. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.
A Novel Telemanipulated Robotic Assistant for Surgical Endoscopy: Preclinical Application to ESD.
Zorn, Lucile; Nageotte, Florent; Zanne, Philippe; Legner, Andras; Dallemagne, Bernard; Marescaux, Jacques; de Mathelin, Michel
2018-04-01
Minimally invasive surgical interventions in the gastrointestinal tract, such as endoscopic submucosal dissection (ESD), are very difficult for surgeons when performed with standard flexible endoscopes. Robotic flexible systems have been identified as a solution to improve manipulation. However, only a few such systems have been brought to preclinical trials as of now. As a result, novel robotic tools are required. We developed a telemanipulated robotic device, called STRAS, which aims to assist surgeons during intraluminal surgical endoscopy. This is a modular system, based on a flexible endoscope and flexible instruments, which provides 10 degrees of freedom (DoFs). The modularity allows the user to easily set up the robot and to navigate toward the operating area. The robot can then be teleoperated using master interfaces specifically designed to intuitively control all available DoFs. STRAS capabilities have been tested in laboratory conditions and during preclinical experiments. We report 12 colorectal ESDs performed in pigs, in which large lesions were successfully removed. Dissection speeds are compared with those obtained in similar conditions with the manual Anubiscope platform from Karl Storz. We show significant improvements ( ). These experiments show that STRAS (v2) provides sufficient DoFs, workspace, and force to perform ESD, that it allows a single surgeon to perform all the surgical tasks and those performances are improved with respect to manual systems. The concepts developed for STRAS are validated and could bring new tools for surgeons to improve comfort, ease, and performances for intraluminal surgical endoscopy.
A new AS-display as part of the MIRO lightweight robot for surgical applications
Grossmann, Christoph M.
2010-02-01
The DLR MIRO is the second generation of versatile robot arms for surgical applications, developed at the Institute for Robotics and Mechatronics at Deutsche Zentrum für Luft- und Raumfahrt (DLR) in Oberpfaffenhofen, Germany. With its low weight of 10 kg and dimensions similar to those of the human arm, the MIRO robot can assist the surgeon directly at the operating table where space is scarce. The planned scope of applications of this robot arm ranges from guiding a laser unit for the precise separation of bone tissue in orthopedics to positioning holes for bone screws, robot assisted endoscope guidance and on to the multi-robot concept for endoscopic minimally invasive surgery. A stereo-endoscope delivers two full HD video streams that can even be augmented with information, e.g vectors indicating the forces that act on the surgical tool at any given moment. SeeFront's new autostereoscopic 3D display SF 2223, being a part of the MIRO assembly, will let the surgeon view the stereo video stream in excellent quality, in real time and without the need for any viewing aids. The presentation is meant to provide an insight into the principles at the basis of the SeeFront 3D technology and how they allow the creation of autostereoscopic display solutions ranging from smallest "stamp-sized" displays to 30" desktop versions, which all provide comfortable freedom of movement for the viewer along with excellent 3D image quality.
Robotic Control of a Traditional Flexible Endoscope for Therapy
Ruiter, Jeroen; Bonnema, Gerrit Maarten; van der Voort, Mascha C.; Broeders, Ivo Adriaan Maria Johannes
2013-01-01
In therapeutic flexible endoscopy a team of physician and assistant(s) is required to control all independent translations and rotations of the flexible endoscope and its instruments. As a consequence the physician lacks valuable force feedback information on tissue interaction, communication errors
Medical capsule robots: A renaissance for diagnostics, drug delivery and surgical treatment.
Mapara, Sanyat S; Patravale, Vandana B
2017-09-10
The advancements in electronics and the progress in nanotechnology have resulted in path breaking development that will transform the way diagnosis and treatment are carried out currently. This development is Medical Capsule Robots, which has emerged from the science fiction idea of robots travelling inside the body to diagnose and cure disorders. The first marketed capsule robot was a capsule endoscope developed to capture images of the gastrointestinal tract. Today, varieties of capsule endoscopes are available in the market. They are slightly larger than regular oral capsules, made up of a biocompatible case and have electronic circuitry and mechanisms to capture and transmit images. In addition, robots with diagnostic features such as in vivo body temperature detection and pH monitoring have also been launched in the market. However, a multi-functional unit that will diagnose and cure diseases inside the body has not yet been realized. A remote controlled capsule that will undertake drug delivery and surgical treatment has not been successfully launched in the market. High cost, inadequate power supply, lack of control over drug release, limited space for drug storage on the capsule, inadequate safety and no mechanisms for active locomotion and anchoring have prevented their entry in the market. The capsule robots can revolutionize the current way of diagnosis and treatment. This paper discusses in detail the applications of medical capsule robots in diagnostics, drug delivery and surgical treatment. In diagnostics, detailed analysis has been presented on wireless capsule endoscopes, issues associated with the marketed versions and their corresponding solutions in literature. Moreover, an assessment has been made of the existing state of remote controlled capsules for targeted drug delivery and surgical treatment and their future impact is predicted. Besides the need for multi-functional capsule robots and the areas for further research have also been
Stimulus intensity for hand held and robotic transcranial magnetic stimulation.
Richter, Lars; Trillenberg, Peter; Schweikard, Achim; Schlaefer, Alexander
2013-05-01
Transcranial Magnetic Stimulation (TMS) is based on a changing magnetic field inducing an electric field in the brain. Conventionally, the TMS coil is mounted to a static holder and the subject is asked to avoid head motion. Additionally, head resting frames have been used. In contrast, our robotized TMS system employs active motion compensation (MC) to maintain the correct coil position. We study the effect of patient motion on TMS. In particular, we compare different coil positioning techniques with respect to the induced electric field. We recorded head motion for six subjects in three scenarios: (a) avoiding head motion, (b) using a head rest, and (c) moving the head freely. Subsequently, the motion traces were replayed using a second robot to move a sensor to measure the electric field in the target region. These head movements were combined with 2 types of coil positioning: (1) using a coil holder and (2) using robotized TMS with MC. After 30 min the induced electric field was reduced by 32.0% and 19.7% for scenarios (1a) and (1b), respectively. For scenarios (2a)-(2c) it was reduced by only 4.9%, 1.4% and 2.0%, respectively, which is a significant improvement (P < 0.05). Furthermore, the orientation of the induced field changed by 5.5°, 7.6°, 0.4°, 0.2°, 0.2° for scenarios (1a)-(2c). While none of the scenarios required rigid head fixation, using a simple holder to position a coil during TMS can lead to substantial deviations in the induced electric field. In contrast, robotic motion compensation results in clinically acceptable positioning throughout treatment. Copyright © 2013 Elsevier Inc. All rights reserved.
Transoral robotic-assisted laryngeal cleft repair in the pediatric patient.
Leonardis, Rachel L; Duvvuri, Umamaheswar; Mehta, Deepak
2014-09-01
To assess the feasibility of performing robotic-assisted laryngeal cleft repair in the pediatric population. Retrospective chart review at a tertiary academic children's hospital. All patients underwent transoral robotic-assisted laryngeal cleft repair from March 2011 to June 2013. Demographics, robotic docking time, operative time, and postoperative course and swallowing function were collected and analyzed. Five children, three male and two female, underwent successful transoral robotic-assisted laryngeal cleft repair for closure of a type I laryngeal cleft. Mean age at time of surgery was 21.6 months (standard deviation 6.1 months; range, 15-29 months). From case 1 to case 5, robotic docking time (18-10 minutes), robotic operative time (102-36 minutes), and total operating room time (173-105 minutes) decreased. There were no complications with time until extubation (range, 2-3 days), length of intensive care unit stay (range, 3-4 days), and total hospital stay (range, 3-5 days) within acceptable range following laryngeal cleft repair. Modified barium swallow (two patients) or fiberoptic endoscopic evaluation of swallowing (three patients) was performed postoperatively, with all patients showing complete resolution of penetration and aspiration. In addition, all patients experienced subjective resolution of dysphagia and/or choking with feeds postoperatively. Transoral robotic-assisted laryngeal cleft repair may offer specific advantages over a traditional endoscopic approach. In our experience, the procedure was well tolerated and associated with definitive surgical cure in all patients. The scope of robotic technology continually expands and should be considered a feasible tool at an institution-based level. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.
Robotic assisted minimally invasive surgery
Directory of Open Access Journals (Sweden)
Palep Jaydeep
2009-01-01
Full Text Available The term "robot" was coined by the Czech playright Karel Capek in 1921 in his play Rossom′s Universal Robots. The word "robot" is from the check word robota which means forced labor.The era of robots in surgery commenced in 1994 when the first AESOP (voice controlled camera holder prototype robot was used clinically in 1993 and then marketed as the first surgical robot ever in 1994 by the US FDA. Since then many robot prototypes like the Endoassist (Armstrong Healthcare Ltd., High Wycombe, Buck, UK, FIPS endoarm (Karlsruhe Research Center, Karlsruhe, Germany have been developed to add to the functions of the robot and try and increase its utility. Integrated Surgical Systems (now Intuitive Surgery, Inc. redesigned the SRI Green Telepresence Surgery system and created the daVinci Surgical System ® classified as a master-slave surgical system. It uses true 3-D visualization and EndoWrist ® . It was approved by FDA in July 2000 for general laparoscopic surgery, in November 2002 for mitral valve repair surgery. The da Vinci robot is currently being used in various fields such as urology, general surgery, gynecology, cardio-thoracic, pediatric and ENT surgery. It provides several advantages to conventional laparoscopy such as 3D vision, motion scaling, intuitive movements, visual immersion and tremor filtration. The advent of robotics has increased the use of minimally invasive surgery among laparoscopically naοve surgeons and expanded the repertoire of experienced surgeons to include more advanced and complex reconstructions.
Directory of Open Access Journals (Sweden)
Gabriel N Meloni
Full Text Available A simple and cost effective alternative for fabricating custom Scanning Electron Microscope (SEM sample holders using 3D printers and conductive polylactic acid filament is presented. The flexibility of the 3D printing process allowed for the fabrication of sample holders with specific features that enable the high-resolution imaging of nanoelectrodes and nanopipettes. The precise value of the inner semi cone angle of the nanopipettes taper was extracted from the acquired images and used for calculating their radius using electrochemical methods. Because of the low electrical resistivity presented by the 3D printed holder, the imaging of non-conductive nanomaterials, such as alumina powder, was found to be possible. The fabrication time for each sample holder was under 30 minutes and the average cost was less than $0.50 per piece. Despite being quick and economical to fabricate, the sample holders were found to be sufficiently resistant, allowing for multiple uses of the same holder.
New Developments in Robotics and Single-site Gynecologic Surgery.
Matthews, Catherine A
2017-06-01
Within the last 10 years there have been significant advances in minimal-access surgery. Although no emerging technology has demonstrated improved outcomes or fewer complications than standard laparoscopy, the introduction of the robotic surgical platform has significantly lowered abdominal hysterectomy rates. While operative time and cost were higher in robotic-assisted procedures when the technology was first introduced, newer studies demonstrate equivalent or improved robotic surgical efficiency with increased experience. Single-port hysterectomy has not improved postoperative pain or subjective cosmetic results. Emerging platforms with flexible, articulating instruments may increase the uptake of single-port procedures including natural orifice transluminal endoscopic cases.
Directory of Open Access Journals (Sweden)
Mohammed Myasar Ali
2017-07-01
Full Text Available In automated working environments, mobile robots can be used for different purposes such as material handling, domestic services, and objects transportation. This work presents a grasping and placing operation for multiple labware and tube racks in life science laboratories using the H20 mobile robots. The H20 robot has dual arms where each arm consists of 6 revolute joints with 6-DOF and 2-DOF grippers. The labware, which have to be manipulated and transported, contain chemical and biological components. Therefore, an accurate approach for object recognition and position estimation is required. The recognition and pose estimation of the desired objects are very essential to guide the robotic arm in the manipulation tasks. In this work, the problem statement of H20 transportation system with the proposed methodology are presented. Different strategies (visual and non-visual of labware manipulation using mobile robots are described. The H20 robot is equipped with a Kinect V2 sensor to identify and estimate the position of the target. The local features recognition based on SURF algorithm (Speeded-Up Robust Features is used. The recognition process is performed for the required labware and holder to perform the grasping and placing operation. A strategy is proposed to find the required holder and to check its emptiness for the placing tasks. Different styles of grippers and labware containers are used to manipulate different weights of labware and to realize a safe transportation. The parts of mobile robot transportation system are communicated with each other using Asynchronous socket Channels.
Hybrid Microscopic-Endoscopic Surgery for Craniopharyngioma in Neurosurgical Suite: Technical Notes.
Ichikawa, Tomotsugu; Otani, Yoshihiro; Ishida, Joji; Fujii, Kentaro; Kurozumi, Kazuhiko; Ono, Shigeki; Date, Isao
2016-01-01
The best chance of curing craniopharyngioma is achieved by microsurgical total resection; however, its location adjacent to critical structures hinders complete resection without neurologic deterioration. Unrecognized residual tumor within microscopic blind spots might result in tumor recurrences. To improve outcomes, new techniques are necessary to visualize tissue within these blind spots. We examined the success of hybrid microscopic-endoscopic neurosurgery for craniopharyngioma in a neurosurgical suite. Four children with craniopharyngiomas underwent microscopic resection. When the neurosurgeon was confident that most of the visible tumor was removed but was suspicious of residual tumor within the blind spot, he or she used an integrated endoscope-holder system to inspect and remove any residual tumor. Two ceiling monitors were mounted side by side in front of the surgeon to display both microscopic and endoscopic views and to view both monitors simultaneously. Surgery was performed in all patients via the frontobasal interhemispheric approach. Residual tumors were observed in the sella (2 patients), on the ventral surface of the chiasm and optic nerve (1 patient), and in the third ventricle (1 patient) and were resected to achieve total resection. Postoperatively, visual function was improved in 2 patients and none exhibited deterioration related to the surgery. Simultaneous microscopic and endoscopic observation with the use of dual monitors in a neurosurgical suite was ergonomically optimal for the surgeon to perform microsurgical procedures and to avoid traumatizing surrounding vessels or neural tissues. Hybrid microscopic-endoscopic neurosurgery may contribute to safe, less-invasive, and maximal resection to achieve better prognosis in children with craniopharyngioma. Copyright © 2016 Elsevier Inc. All rights reserved.
Towards Light‐guided Micro‐robotics
DEFF Research Database (Denmark)
Glückstad, Jesper
‐dimensional microstructures. Furthermore, we exploit the light shaping capabilities available in the workstation to demonstrate a new strategy for controlling microstructures that goes beyond the typical refractive light deflections that are exploited in conventional optical trapping and manipulation e.g. of micro......Robotics in the macro‐scale typically uses light for carrying information in machine vision for monitoring and feedback in intelligent robotic guidance systems. With light’s miniscule momentum, shrinking robots down to the micro‐scale regime creates opportunities for exploiting optical forces...... and torques in micro‐robotic actuation and control. Indeed, the literature on optical trapping and micro‐manipulation attests to the possibilities for optical micro‐robotics. Advancing light‐driven micro‐robotics requires the optimization of optical force and optical torque that, in turn, requires...
19 CFR 10.7 - Substantial containers or holders.
2010-04-01
... 19 Customs Duties 1 2010-04-01 2010-04-01 false Substantial containers or holders. 10.7 Section 10... Exported and Returned § 10.7 Substantial containers or holders. (a) Substantial containers or holders... domestic products exported and returned. When such containers or holders are imported not containing or...
Remote Viewing End Effectors for Light Duty Utility Arm Robot (U)
International Nuclear Information System (INIS)
Heckendorn, F.M.; Robinson, C.W.; Haynes, H.B.; Anderosn, E.K.; Pardini, A.F.
1996-01-01
The Robotics Development Groups at the Savannah River Site (SRS) and at the Hanford site have developed remote video and photography systems for deployment in underground radioactive-waste storage tanks at the Department of Energy (DOE) sites as a part of the Office of Science and Technology (OST) program within DOE. Viewing and documenting the tank interiors and their associated annular spaces is an extremely valuable tool in characterizing their condition and contents and in controlling their remediation. Several specialized video/photography systems and robotic End Effectors have been fabricated that provide remote viewing and lighting. All are remotely deployable into and out of the tank, with all viewing functions remotely operated. Positioning all control components away from the facility prevents the potential for personnel exposure to radiation and contamination. Only the remote video systems are discussed in this paper
Diffeomorphisms Holder conjugate to Anosov diffeomorphisms
Gogolev, Andrey
2008-01-01
We show by means of a counterexample that a $C^{1+Lip}$ diffeomorphism Holder conjugate to an Anosov diffeomorphism is not necessarily Anosov. The counterexample can bear higher smoothness up to $C^3$. Also we include a result from the 2006 Ph.D. thesis of T. Fisher: a $C^{1+Lip}$ diffeomorphism Holder conjugate to an Anosov diffeomorphism is Anosov itself provided that Holder exponents of the conjugacy and its inverse are sufficiently large.
International Nuclear Information System (INIS)
Hattori, Asaki; Suzuki, Naoki; Tanoue, Kazuo; Ieiri, Satoshi; Konishi, Kozo; Tomikawa, Morimasa; Kenmotsu, Hajime; Hashizume, Makoto
2010-01-01
This study reports the development of patient's integrated information-displaying system at image-guided, robotic peroral endoscopic operation of digestive tracts as well as the actual operative field for the operator not to look aside. The peroral endoscope has, at its top, a magnetic position sensor and 2 robotic manipulative forceps at right and left side to navigate the surgery through following 3 windows of superimposing display: the inner peritoneal 3D structure of the real operative field reconstructed from preoperative CT and MR images by volume rendering, presentation of the robot top tip in the structure above and in the preoperative CT or MR image as an ordinary navigation. Furthermore, the robot has a function to measure softness of its grabbing tissue which is displayed in the corresponding right and left superimposing windows, and signs like the real-time blood pressure and heart rate are also given in another window. All of the patient's integrated information-displaying can be handled at will during the operation. Improvement of user interface and of navigation display is further to be conducted. (T.T.)
Buchs, Nicolas C; Volonte, Francesco; Pugin, François; Toso, Christian; Fusaglia, Matteo; Gavaghan, Kate; Majno, Pietro E; Peterhans, Matthias; Weber, Stefan; Morel, Philippe
2013-10-01
Stereotactic navigation technology can enhance guidance during surgery and enable the precise reproduction of planned surgical strategies. Currently, specific systems (such as the CAS-One system) are available for instrument guidance in open liver surgery. This study aims to evaluate the implementation of such a system for the targeting of hepatic tumors during robotic liver surgery. Optical tracking references were attached to one of the robotic instruments and to the robotic endoscopic camera. After instrument and video calibration and patient-to-image registration, a virtual model of the tracked instrument and the available three-dimensional images of the liver were displayed directly within the robotic console, superimposed onto the endoscopic video image. An additional superimposed targeting viewer allowed for the visualization of the target tumor, relative to the tip of the instrument, for an assessment of the distance between the tumor and the tool for the realization of safe resection margins. Two cirrhotic patients underwent robotic navigated atypical hepatic resections for hepatocellular carcinoma. The augmented endoscopic view allowed for the definition of an accurate resection margin around the tumor. The overlay of reconstructed three-dimensional models was also used during parenchymal transection for the identification of vascular and biliary structures. Operative times were 240 min in the first case and 300 min in the second. There were no intraoperative complications. The da Vinci Surgical System provided an excellent platform for image-guided liver surgery with a stable optic and instrumentation. Robotic image guidance might improve the surgeon's orientation during the operation and increase accuracy in tumor resection. Further developments of this technological combination are needed to deal with organ deformation during surgery. Copyright © 2013 Elsevier Inc. All rights reserved.
Surgery with cooperative robots.
Lehman, Amy C; Berg, Kyle A; Dumpert, Jason; Wood, Nathan A; Visty, Abigail Q; Rentschler, Mark E; Platt, Stephen R; Farritor, Shane M; Oleynikov, Dmitry
2008-03-01
Advances in endoscopic techniques for abdominal procedures continue to reduce the invasiveness of surgery. Gaining access to the peritoneal cavity through small incisions prompted the first significant shift in general surgery. The complete elimination of external incisions through natural orifice access is potentially the next step in reducing patient trauma. While minimally invasive techniques offer significant patient advantages, the procedures are surgically challenging. Robotic surgical systems are being developed that address the visualization and manipulation limitations, but many of these systems remain constrained by the entry incisions. Alternatively, miniature in vivo robots are being developed that are completely inserted into the peritoneal cavity for laparoscopic and natural orifice procedures. These robots can provide vision and task assistance without the constraints of the entry incision, and can reduce the number of incisions required for laparoscopic procedures. In this study, a series of minimally invasive animal-model surgeries were performed using multiple miniature in vivo robots in cooperation with existing laparoscopy and endoscopy tools as well as the da Vinci Surgical System. These procedures demonstrate that miniature in vivo robots can address the visualization constraints of minimally invasive surgery by providing video feedback and task assistance from arbitrary orientations within the peritoneal cavity.
Improved sample holders for the PMMA dosimeters
International Nuclear Information System (INIS)
Kobayashi, Toshikazu; Sone, Koji; Iso, Katsuaki
1994-01-01
PMMA dosimeters are widely used for high dose dosimetry. Dose is determined by measuring the change in optical density of the irradiated PMMA dosimeter element. Measurement precision depends on the mounting method of a dosimeter element in the sample room of a spectrophotometer. We tried to prepare three types of holders, (holders A, B and C in Figs. 1-3), according to the shape of PMMA dosimeter elements. We measured optical density of the irradiated PMMA dosimeter elements by using the three types of holders. It is revealed that the holder of the type A gives more precise results for the Red 4034 or Gammachrome YR dosimeter than that of the type B. The measurements with a spectrophotometer using the type C holder gives better results for the Red acrylic dosimeter than the case of the measurements by the exclusive reader. (author)
An illumination system for endoscopic applications
DEFF Research Database (Denmark)
2013-01-01
The present disclosure relates to an illumination system for endoscopic applications comprising at least one substantially monochromatic light source having a predefined central wavelength between 400 and 500 nm or between 500 and 550 nm, an optical transmission path adapted to guide light emanat...... for photodynamic diagnosis and/or therapy of bladder cancer is further disclosed herein....
Robotics in Cardiac Surgery: Past, Present, and Future
Directory of Open Access Journals (Sweden)
Bryan Bush
2013-07-01
Full Text Available Robotic cardiac operations evolved from minimally invasive operations and offer similar theoretical benefits, including less pain, shorter length of stay, improved cosmesis, and quicker return to preoperative level of functional activity. The additional benefits offered by robotic surgical systems include improved dexterity and degrees of freedom, tremor-free movements, ambidexterity, and the avoidance of the fulcrum effect that is intrinsic when using long-shaft endoscopic instruments. Also, optics and operative visualization are vastly improved compared with direct vision and traditional videoscopes. Robotic systems have been utilized successfully to perform complex mitral valve repairs, coronary revascularization, atrial fibrillation ablation, intracardiac tumor resections, atrial septal defect closures, and left ventricular lead implantation. The history and evolution of these procedures, as well as the present status and future directions of robotic cardiac surgery, are presented in this review.
Manipulator for rotating and translating a sample holder
van de Water, Jeroen [Breugel, NL; van den Oetelaar, Johannes [Eindhoven, NL; Wagner, Raymond [Gorinchem, NL; Slingerland, Hendrik Nicolaas [Venlo, NL; Bruggers, Jan Willem [Eindhoven, NL; Ottevanger, Adriaan Huibert Dirk [Malden, NL; Schmid, Andreas [Berkeley, CA; Olson, Eric A [Champaign, IL; Petrov, Ivan G [Champaign, IL; Donchev, Todor I [Urbana, IL; Duden, Thomas [Kensington, CA
2011-02-08
A manipulator for use in e.g. a Transmission Electron Microscope (TEM) is described, said manipulator capable of rotating and translating a sample holder (4). The manipulator clasps the round sample holder between two members (3A, 3B), said members mounted on actuators (2A, 2B). Moving the actuators in the same direction results in a translation of the sample holder, while moving the actuators in opposite directions results in a rotation of the sample holder.
First experience with THE AUTOLAP™ SYSTEM: an image-based robotic camera steering device.
Wijsman, Paul J M; Broeders, Ivo A M J; Brenkman, Hylke J; Szold, Amir; Forgione, Antonello; Schreuder, Henk W R; Consten, Esther C J; Draaisma, Werner A; Verheijen, Paul M; Ruurda, Jelle P; Kaufman, Yuval
2018-05-01
Robotic camera holders for endoscopic surgery have been available for 20 years but market penetration is low. The current camera holders are controlled by voice, joystick, eyeball tracking, or head movements, and this type of steering has proven to be successful but excessive disturbance of surgical workflow has blocked widespread introduction. The Autolap™ system (MST, Israel) uses a radically different steering concept based on image analysis. This may improve acceptance by smooth, interactive, and fast steering. These two studies were conducted to prove safe and efficient performance of the core technology. A total of 66 various laparoscopic procedures were performed with the AutoLap™ by nine experienced surgeons, in two multi-center studies; 41 cholecystectomies, 13 fundoplications including hiatal hernia repair, 4 endometriosis surgeries, 2 inguinal hernia repairs, and 6 (bilateral) salpingo-oophorectomies. The use of the AutoLap™ system was evaluated in terms of safety, image stability, setup and procedural time, accuracy of imaged-based movements, and user satisfaction. Surgical procedures were completed with the AutoLap™ system in 64 cases (97%). The mean overall setup time of the AutoLap™ system was 4 min (04:08 ± 0.10). Procedure times were not prolonged due to the use of the system when compared to literature average. The reported user satisfaction was 3.85 and 3.96 on a scale of 1 to 5 in two studies. More than 90% of the image-based movements were accurate. No system-related adverse events were recorded while using the system. Safe and efficient use of the core technology of the AutoLap™ system was demonstrated with high image stability and good surgeon satisfaction. The results support further clinical studies that will focus on usability, improved ergonomics and additional image-based features.
Application of da Vinci surgical robotic system in hepatobiliary surgery
Directory of Open Access Journals (Sweden)
Chen Jiahai
2018-01-01
Full Text Available The development of minimally invasive surgery has brought a revolutionary change to surgery techniques, and endoscopic surgical robots, especially Da Vinci robotic surgical system, has further broaden the scope of minimally invasive surgery, which has been applied in a variety of surgical fields including hepatobiliary surgery. Today, the application of Da Vinci surgical robot can cover most of the operations in hepatobiliary surgery which has proved to be safe and practical. What’s more, many clinical studies in recent years have showed that Da Vinci surgical system is superior to traditional laparoscopy. This paper summarize the advantage and disadvantage of Da Vinci surgical system, and outlines the current status of and future perspectives on the robot-assisted hepatobiliary surgery based on the cases reports in recent years of the application of Da Vinci surgical robot.
Wang, Hesheng; Zhang, Runxi; Chen, Weidong; Wang, Xiaozhou; Pfeifer, Rolf
2017-08-01
Minimally invasive surgery attracts more and more attention because of the advantages of minimal trauma, less bleeding and pain and low complication rate. However, minimally invasive surgery for beating hearts is still a challenge. Our goal is to develop a soft robot surgical system for single-port minimally invasive surgery on a beating heart. The soft robot described in this paper is inspired by the octopus arm. Although the octopus arm is soft and has more degrees of freedom (DOFs), it can be controlled flexibly. The soft robot is driven by cables that are embedded into the soft robot manipulator and can control the direction of the end and middle of the soft robot manipulator. The forward, backward and rotation movement of the soft robot is driven by a propulsion plant. The soft robot can move freely by properly controlling the cables and the propulsion plant. The soft surgical robot system can perform different thoracic operations by changing surgical instruments. To evaluate the flexibility, controllability and reachability of the designed soft robot surgical system, some testing experiments have been conducted in vivo on a swine. Through the subxiphoid, the soft robot manipulator could enter into the thoracic cavity and pericardial cavity smoothly and perform some operations such as biopsy, ligation and ablation. The operations were performed successfully and did not cause any damage to the surrounding soft tissues. From the experiments, the flexibility, controllability and reachability of the soft robot surgical system have been verified. Also, it has been shown that this system can be used in the thoracic and pericardial cavity for different operations. Compared with other endoscopy robots, the soft robot surgical system is safer, has more DOFs and is more flexible for control. When performing operations in a beating heart, this system maybe more suitable than traditional endoscopy robots.
National Recordal System IK holder catalogue process
CSIR Research Space (South Africa)
Pretorius, R
2012-10-01
Full Text Available good, based on IK.? Subsequently, the South African Department of Science and Technology (DST) created a National Indigenous Knowledge Systems Office (NIKSO) that is taking the lead on interfacing IKS with other recognised knowledge holders... is to illustrate the South African National Recordal Systems (NRS) process whereby Indigenous Knowledge (IK) holder?s information is captured in a registry, as specified in South Africa?s Indigenous Knowledge Systems (IKS) Policy, through an IK cataloguing...
Socially intelligent robots: dimensions of human-robot interaction.
Dautenhahn, Kerstin
2007-04-29
Social intelligence in robots has a quite recent history in artificial intelligence and robotics. However, it has become increasingly apparent that social and interactive skills are necessary requirements in many application areas and contexts where robots need to interact and collaborate with other robots or humans. Research on human-robot interaction (HRI) poses many challenges regarding the nature of interactivity and 'social behaviour' in robot and humans. The first part of this paper addresses dimensions of HRI, discussing requirements on social skills for robots and introducing the conceptual space of HRI studies. In order to illustrate these concepts, two examples of HRI research are presented. First, research is surveyed which investigates the development of a cognitive robot companion. The aim of this work is to develop social rules for robot behaviour (a 'robotiquette') that is comfortable and acceptable to humans. Second, robots are discussed as possible educational or therapeutic toys for children with autism. The concept of interactive emergence in human-child interactions is highlighted. Different types of play among children are discussed in the light of their potential investigation in human-robot experiments. The paper concludes by examining different paradigms regarding 'social relationships' of robots and people interacting with them.
Robotic laparoendoscopic single-site surgery: From present to future
Directory of Open Access Journals (Sweden)
Ayhan Verit
2012-01-01
Full Text Available The continued effort of improving cosmesis and reducing morbidity in urologic surgery has given rise to novel alternatives to traditional minimally invasive techniques: Laparoendoscopic Single-site Surgery (LESS and Natural Orifice Transluminal Endoscopic Surgery (NOTES. Despite the development of specialized access devices and instruments, the performance of complex procedures using LESS has been challenging due to loss of triangulation and instrument clashing. A robotic interface may represent the key factor in overcoming the critical restrictions related to NOTES and LESS. Although encouraging, current clinical evidence related to R-LESS remains limited as the current da Vinci® robotic platform has not been specifically designed for LESS. Robotic innovations are imminent and are likely to govern major changes to the current landscape of scarless surgery.
Harmonising and Matching IPR Holders at IP Australia
T’Mir D. Julius; Gaétan de Rassenfosse
2014-01-01
This document describes the methodology developed by the Melbourne Institute to: (i) harmonise holders of intellectual property rights (IPRs) at IP Australia (applications for patent, designs, trademarks and plant breeder’s rights); (ii) match Australian IPRs holders to the Australian business register; (iii) identify the ultimate owners within Australia; and (iv) identify which holders are small and medium size enterprises.
Robotics Team Lights Up New Year's Eve
LeBlanc, Cheryl
2011-01-01
A robotics team from Muncie, Indiana--the PhyXTGears--is made up of high school students from throughout Delaware County. The group formed as part of the FIRST Robotics program (For Inspiration and Recognition of Science and Technology), an international program founded by inventor Dean Kamen in which students work with professional engineers and…
Development of a light weighted mobile robot for SG tube inspection in NPP
International Nuclear Information System (INIS)
Seo, Yong Chil; Jeong, Kyung Min; Shin, Hochul; Gweng, Jung Ju; Lee, Sung Uk; Jeong, Seung Ho; Choi, Young Soo; Kim, Seung Ho; Shin, Chun Sup; Park, Ki Tae
2012-01-01
Steam generators (SG) are among the most critical components of pressurized water Nuclear Power Plants (NPP). SG tubes must provide a reliable pressure boundary between the primary and secondary cooling water, because any leakage from tube defects could result in the release of radioactivity to the environment. Thus degradations of steam generators tubes should be monitored and inspected periodically under nuclear regulation. In service inspections of SG tubes are carried out using eddy current test (ECT) and the defected tubes are usually plugged. Because the radioactivity in the internal SG chambers limits free access of human workers, remote manipulators are required. In South Korea, Manipulators such as the Zet ec SM series and the Westinghouse ROSA series have bee used. Such manipulators are rigidly mounted to man ways or tube sheets of SG. Confusions of the inspected tubes may occur from deflection of the manipulators. To reduce the deflections of the manipulators for covering the large working areas of tube sheets, sufficient rigidity is required and that leads to an increase of the weight. Such weight increase results in some difficulties for handling and more radiation exposure of human workers. Recently light weighed mobile robots have been introduced by Westinghouse and Zet ec. The robots can move keeping in contact with the tube sheets using devices which are commonly called cam locks. They are easier to handle and provide no confusion for the position of the inspected tubes. But when the clamping forces are loosed accidentally, they can be fall down and light repair works can be performed. This paper provides the design results for a lightweight mobile robot which is being developed in cooperation of our institutes
Development of a light weighted mobile robot for SG tube inspection in NPP
Energy Technology Data Exchange (ETDEWEB)
Seo, Yong Chil; Jeong, Kyung Min; Shin, Hochul; Gweng, Jung Ju; Lee, Sung Uk; Jeong, Seung Ho; Choi, Young Soo; Kim, Seung Ho [KAERI, Daejeon (Korea, Republic of); Shin, Chun Sup; Park, Ki Tae [Korea Plant Service and Engineering, Busan (Korea, Republic of)
2012-10-15
Steam generators (SG) are among the most critical components of pressurized water Nuclear Power Plants (NPP). SG tubes must provide a reliable pressure boundary between the primary and secondary cooling water, because any leakage from tube defects could result in the release of radioactivity to the environment. Thus degradations of steam generators tubes should be monitored and inspected periodically under nuclear regulation. In service inspections of SG tubes are carried out using eddy current test (ECT) and the defected tubes are usually plugged. Because the radioactivity in the internal SG chambers limits free access of human workers, remote manipulators are required. In South Korea, Manipulators such as the Zet ec SM series and the Westinghouse ROSA series have bee used. Such manipulators are rigidly mounted to man ways or tube sheets of SG. Confusions of the inspected tubes may occur from deflection of the manipulators. To reduce the deflections of the manipulators for covering the large working areas of tube sheets, sufficient rigidity is required and that leads to an increase of the weight. Such weight increase results in some difficulties for handling and more radiation exposure of human workers. Recently light weighed mobile robots have been introduced by Westinghouse and Zet ec. The robots can move keeping in contact with the tube sheets using devices which are commonly called cam locks. They are easier to handle and provide no confusion for the position of the inspected tubes. But when the clamping forces are loosed accidentally, they can be fall down and light repair works can be performed. This paper provides the design results for a lightweight mobile robot which is being developed in cooperation of our institutes.
Conjugation of fiber-coupled wide-band light sources and acousto-optical spectral elements
Machikhin, Alexander; Batshev, Vladislav; Polschikova, Olga; Khokhlov, Demid; Pozhar, Vitold; Gorevoy, Alexey
2017-12-01
Endoscopic instrumentation is widely used for diagnostics and surgery. The imaging systems, which provide the hyperspectral information of the tissues accessible by endoscopes, are particularly interesting and promising for in vivo photoluminescence diagnostics and therapy of tumour and inflammatory diseases. To add the spectral imaging feature to standard video endoscopes, we propose to implement acousto-optical (AO) filtration of wide-band illumination of incandescent-lamp-based light sources. To collect maximum light and direct it to the fiber-optic light guide inside the endoscopic probe, we have developed and tested the optical system for coupling the light source, the acousto-optical tunable filter (AOTF) and the light guide. The system is compact and compatible with the standard endoscopic components.
Directory of Open Access Journals (Sweden)
Defeng Wu
2016-08-01
Full Text Available A robot-based three-dimensional (3D measurement system is presented. In the presented system, a structured light vision sensor is mounted on the arm of an industrial robot. Measurement accuracy is one of the most important aspects of any 3D measurement system. To improve the measuring accuracy of the structured light vision sensor, a novel sensor calibration approach is proposed to improve the calibration accuracy. The approach is based on a number of fixed concentric circles manufactured in a calibration target. The concentric circle is employed to determine the real projected centres of the circles. Then, a calibration point generation procedure is used with the help of the calibrated robot. When enough calibration points are ready, the radial alignment constraint (RAC method is adopted to calibrate the camera model. A multilayer perceptron neural network (MLPNN is then employed to identify the calibration residuals after the application of the RAC method. Therefore, the hybrid pinhole model and the MLPNN are used to represent the real camera model. Using a standard ball to validate the effectiveness of the presented technique, the experimental results demonstrate that the proposed novel calibration approach can achieve a highly accurate model of the structured light vision sensor.
Head-positioning scintillation camera and head holder therefor
International Nuclear Information System (INIS)
Kay, T.D.
1976-01-01
A holder for immobilizing the head of a patient undergoing a vertex brain scan by a Gamma Scintillation Camera is described. The holder has a uniquely designed shape capable of comfortably supporting the head. In addition, this holder can be both adjustably and removably utilized in combination with the scintillation camera so as to enable the brain scan operation to take place while the patient is in the seated position
The effectiveness of an endotracheal tube holder
Directory of Open Access Journals (Sweden)
Byung Gun Lim
2016-01-01
Full Text Available The security of the endotracheal tube (ETT is important in the anesthesia and intensive care settings. Recently, an ETT holder instead of an adhesive tape is frequently used to provide the fixation of the ETT. There are some studies that focused on the effectiveness of the ETT holder in preventing displacement of ETT compared to an adhesive tape (1, 2. I have experienced the use of an ETT holder (E-holder, KS medical, Bucheon, Korea in many different anesthesia settings and recognized its usefulness and convenience other than ETT security in the following specific settings. Firstly, the ETT holder is definitely effective for patients undergoing procedures that frequently require the adjustment of ETT (or double lumen tube location including thoracic surgery. The location of double lumen tube needed for lung separation can be modified for effective ventilation during anesthetic induction or surgery, and after position changes. The tube can be easily relocated to the proper place for lung separation and effective ventilation by unlocking/relocking the button of the ETT holder under flexible bronchoscopic guidance (Fig. 1A, which can facilitate the operative procedure to be performed easily and quickly. Secondly, the ETT holder can be useful in procedures requiring the prone position (3. Especially, it is useful in all circumstances requiring the adjustment of ETT in the prone position. For instance, it is definitely useful for patients with Duchene muscular dystrophy undergoing scoliosis surgery under prone position. Adolescent patients with Duchene muscular dystrophy frequently have tracheobronchial malacia. If so, the airway pressure can be elevated due to the narrowing of the lesion of malacia when changed to the prone position (4. To overcome this problem, a reinforced ETT should be relocated so that it passes the narrowed tracheal lesion under flexible bronchoscopic guidance (Fig. 1B. However, the approach for this management is somewhat
Non-endoscopic Mechanical Endonasal Dacryocystorhinostomy
Directory of Open Access Journals (Sweden)
Mohammad Etezad Razavi
2011-01-01
Full Text Available To circumvent the disadvantages of endoscopic dacryocystorhinostomy such as small rhinostomy size, high failure rate and expensive equipment, we hereby introduce a modified technique of non-endoscopic mechanical endonasal dacryocystorhinostomy (NE-MEDCR. Surgery is performed under general anesthesia with local decongestion of the nasal mucosa. A 20-gauge vitrectomy light probe is introduced through the upper canaliculus until it touches the bony medial wall of the lacrimal sac. While directly viewing the transilluminated target area, a nasal speculum with a fiber optic light carrier is inserted. An incision is made vertically or in a curvilinear fashion on the nasal mucosa in the lacrimal sac down to the bone using a Freer periosteum elevator. Approximately 1 to 1.5 cm of nasal mucosa is removed with Blakesley forceps. Using a lacrimal punch, the thick bone of the frontal process of the maxilla is removed and the inferior half of the sac is uncovered. The lacrimal sac is tented into the surgical site with the light probe and its medial wall is incised using a 3.2 mm keratome and then excised using the Blakesley forceps. The procedure is completed by silicone intubation. The NE-MEDCR technique does not require expensive instrumentation and is feasible in any standard ophthalmic surgical setting.
Acceptance Testing of Thermoluminescent Dosimeter Holders.
Romanyukha, Alexander; Grypp, Matthew D; Sharp, Thad J; DiRito, John N; Nelson, Martin E; Mavrogianis, Stanley T; Torres, Jeancarlo; Benevides, Luis A
2018-05-01
The U.S. Navy uses the Harshaw 8840/8841 dosimetric (DT-702/PD) system, which employs LiF:Mg,Cu,P thermoluminescent dosimeters (TLDs), developed and produced by Thermo Fisher Scientific (TFS). The dosimeter consists of four LiF:Mg,Cu,P elements, mounted in Teflon® on an aluminum card and placed in a plastic holder. The holder contains a unique filter for each chip made of copper, acrylonitrile butadiene styrene (ABS), Mylar®, and tin. For accredited dosimetry labs, the ISO/IEC 17025:2005(E) requires an acceptance procedure for all new equipment. The Naval Dosimetry Center (NDC) has developed and tested a new non-destructive procedure, which enables the verification and the evaluation of embedded filters in the holders. Testing is based on attenuation measurements of low-energy radiation transmitted through each filter in a representative sample group of holders to verify that the correct filter type and thickness are present. The measured response ratios are then compared with the expected response ratios. In addition, each element's measured response is compared to the mean response of the group. The test was designed and tested to identify significant nonconformities, such as missing copper or tin filters, double copper or double tin filters, or other nonconformities that may impact TLD response ratios. During the implementation of the developed procedure, testing revealed a holder with a double copper filter. To complete the evaluation, the impact of the nonconformities on proficiency testing was examined. The evaluation revealed failures in proficiency testing categories III and IV when these dosimeters were irradiated to high-energy betas.
38 CFR 36.4341 - Death or insolvency of holder.
2010-07-01
... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Death or insolvency of... Death or insolvency of holder. (a) Immediately upon the death of the holder and without the necessity of... applicable in the event of: (1) Insolvency of holder; (2) Initiation of any bankruptcy or reorganization, or...
21 CFR 882.4460 - Neurosurgical head holder (skull clamp).
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neurosurgical head holder (skull clamp). 882.4460... holder (skull clamp). (a) Identification. A neurosurgical head holder (skull clamp) is a device used to clamp the patient's skull to hold head and neck in a particular position during surgical procedures. (b...
Egi, H; Hattori, M; Tokunaga, M; Suzuki, T; Kawaguchi, K; Sawada, H; Ohdan, H
2013-01-01
The aim of this study was to determine whether any correlation exists between the performance of the Mimic® dV-Trainer (Mimic Technologies, Seattle, Wash., USA) and the da Vinci Surgical System (Intuitive Surgical, Sunnyvale, Calif., USA). Twelve participants were recruited, ranging from residents to consultants. We used four training tasks, consisting of 'Pick and Place', 'Peg Board', 'Thread the Rings' and 'Suture Sponge', from the software program of the Mimic dV-Trainer. The performance of the participants was recorded and measured. Additionally, we prepared the same tasks for the da Vinci Surgical System. All participants completed the tasks using the da Vinci Surgical System and were assessed according to time, the Objective Structured Assessment of Technical Skill checklist and the global rating score for endoscopic suturing assessed by two independent blinded observers. After performing these tasks, the participants completed a questionnaire that evaluated the Mimic dV-Trainer's face and content validity. The final results for each participant for the Mimic dV-Trainer and the da Vinci Surgical System were compared. All participants ranked the Mimic dV-Trainer as a realistic training platform that is useful for residency training. There was a significant relationship between the Mimic dV-Trainer and the da Vinci Surgical System in all four tasks. We verified the reliability of the assessment of the checklist and the global rating scores for endoscopic suturing assessed by the two blinded observers using Cronbach's alpha test (r = 0.803, 0.891). We evaluated the concurrent validity of the Mimic dV-Trainer and the da Vinci Surgical System. Our results suggest the possibility that training using the Mimic dV-Trainer may therefore be able to improve the operator's performance during live robot-assisted surgery. © 2013 S. Karger AG, Basel.
Unilateral robotic hybrid mini-maze: a novel experimental approach.
Moslemi, Mohammad; Rawashdeh, Badi; Meyer, Mark; Nguyen, Duy; Poston, Robert; Gharagozloo, Farid
2016-03-01
A complete Cox maze IV procedure is difficult to accomplish using current endoscopic and minimally invasive techniques. These techniques are hampered by inability to adequately dissect the posterior structures of the heart and place all necessary lesions. We present a novel approach, using robotic technology, that achieves placement of all the lesions of the complete maze procedure. In three cadaveric human models, the technical feasibility of using robotic instruments through the right chest to dissect the posterior structures of the heart and place all Cox maze lesions was performed. The entire posterior aspect of the heart was dissected in the cadaveric model facilitating successful placement of all Cox maze IV lesions with robotic assistance through minimally invasive incisions. The robotic Cox maze IV procedure through the novel right thoracic approach is feasible. This obviates the need for sternotomy and avoids the associated morbidity of the conventional Cox-maze procedure. Copyright © 2015 John Wiley & Sons, Ltd.
Ergonomic design and evaluation of a diagnostic ultrasound transducer holder.
Ghasemi, Mohamad Sadegh; Hosseinzadeh, Payam; Zamani, Farhad; Ahmadpoor, Hossein; Dehghan, Naser
2017-12-01
Work-related musculoskeletal disorders (WMSDs) are injuries and disorders that affect the body's movement and musculoskeletal system. Awkward postures represent one of the major ergonomic risk factors that cause WMSDs among sonographers while working with an ultrasound transducer. This study aimed to design and evaluate a new holder for the ultrasound transducer. In the first phase a new holder was designed for the transducer, considering design principles. Evaluation of the new holder was then carried out by electrogoniometry and a locally perceived discomfort (LPD) scale. The application of design principles to the new holder resulted in an improvement of wrist posture and comfort. Wrist angles in extension, flexion, radial deviation and ulnar deviation were lower with utilization of the new holder. The severity of discomfort based on the LPD method in the two modes of work with and without the new holder was reported with values of 1.3 and 1.8, respectively (p ergonomics design principles was effective in minimizing wrist deviation and increasing comfort while working with the new holder.
High-quality endoscope reprocessing decreases endoscope contamination.
Decristoforo, P; Kaltseis, J; Fritz, A; Edlinger, M; Posch, W; Wilflingseder, D; Lass-Flörl, C; Orth-Höller, D
2018-02-24
Several outbreaks of severe infections due to contamination of gastrointestinal (GI) endoscopes, mainly duodenoscopes, have been described. The rate of microbial endoscope contamination varies dramatically in literature. The aim of this multicentre prospective study was to evaluate the hygiene quality of endoscopes and automated endoscope reprocessors (AERs) in Tyrol/Austria. In 2015 and 2016, a total of 463 GI endoscopes and 105 AERs from 29 endoscopy centres were analysed by a routine (R) and a combined routine and advanced (CRA) sampling procedure and investigated for microbial contamination by culture-based and molecular-based analyses. The contamination rate of GI endoscopes was 1.3%-4.6% according to the national guideline, suggesting that 1.3-4.6 patients out of 100 could have had contacts with hygiene-relevant microorganisms through an endoscopic intervention. Comparison of R and CRA sampling showed 1.8% of R versus 4.6% of CRA failing the acceptance criteria in phase I and 1.3% of R versus 3.0% of CRA samples failing in phase II. The most commonly identified indicator organism was Pseudomonas spp., mainly Pseudomonas oleovorans. None of the tested viruses were detected in 40 samples. While AERs in phase I failed (n = 9, 17.6%) mainly due to technical faults, phase II revealed lapses (n = 6, 11.5%) only on account of microbial contamination of the last rinsing water, mainly with Pseudomonas spp. In the present study the contamination rate of endoscopes was low compared with results from other European countries, possibly due to the high quality of endoscope reprocessing, drying and storage. Copyright © 2018 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Perancangan Robot Light Follower untuk Kursi Otomatis dengan Menggunakan Mikrokontroler ATmega 328P
Directory of Open Access Journals (Sweden)
Roslidar Roslidar
2017-08-01
Full Text Available This article discusses the design of light follower chair prototype with speed adjustment of DC motor according to light intensity using microcontroller ATmega328p. This prototype provides a solution for a chair to be back on the position under the table automatically by using a light follower robot principle. There are many possible positions of a chair after being used: perpendicular or sideways to the table. As the positions after being used are varied, the light is used to direct the chair toward under the table since the light can reach the area around the chair except for the back area. This prototype functions well if the chair is heading to the table and is not designed to function in the backward position. LDR (Light Dependent Resistor sensors are used to detect the light. As the source of light, 1 W high power LED is put under the table. A microcontroller ATmega328p is used to execute the input and output of this system. Two DC motor are used as actuators to control the movement of the chair toward the light under the table. Ultrasonic sensors HC-SR04 are used to measure the distance between the table and the chair so that the chair can stop at the desired position.
Directory of Open Access Journals (Sweden)
Ponlachart Chotikarn
2010-10-01
Full Text Available A submarine robot is a semi-autonomous submarine robot used mainly for marine environmental research. We aim todevelop a low cost, semi-autonomous submarine robot which is able to travel underwater. The robot’s structure was designedand patented using a novel idea of the diving system employing a volume adjustment mechanism to vary the robot’s density.A light weight, flexibility and small structure provided by PVC can be used to construct the torpedo-liked shape robot.Hydraulic seal and O-ring rubbers are used to prevent water leaking. This robot is controlled by a wired communicationsystem.
Endoscopic retrograde cholangiopancreatography and endoscopic ...
African Journals Online (AJOL)
An approach to suspected gallstone pancreatitis'based on endoscopic retrograde cholangiopancreatography (ERCP) and endoscopic sphincterotomy (ES) was adopted in 1976 and was followed in 29 patients. ERCp became the routine method of early biliary tract assessment when gallstone pancreatitis was suspected on ...
12 CFR 569.3 - Holders of proxies.
2010-01-01
... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Holders of proxies. 569.3 Section 569.3 Banks and Banking OFFICE OF THRIFT SUPERVISION, DEPARTMENT OF THE TREASURY PROXIES § 569.3 Holders of proxies. No proxy of a mutual savings association with a term greater than eleven months or solicited at...
Vega, David; Kiekens, Kelli C.; Syson, Nikolas C.; Romano, Gabriella; Baker, Tressa; Barton, Jennifer K.
2018-02-01
While Optical Coherence Microscopy (OCM), Multiphoton Microscopy (MPM), and narrowband imaging are powerful imaging techniques that can be used to detect cancer, each imaging technique has limitations when used by itself. Combining them into an endoscope to work in synergy can help achieve high sensitivity and specificity for diagnosis at the point of care. Such complex endoscopes have an elevated risk of failure, and performing proper modelling ensures functionality and minimizes risk. We present full 2D and 3D models of a multimodality optical micro-endoscope to provide real-time detection of carcinomas, called a salpingoscope. The models evaluate the endoscope illumination and light collection capabilities of various modalities. The design features two optical paths with different numerical apertures (NA) through a single lens system with a scanning optical fiber. The dual path is achieved using dichroic coatings embedded in a triplet. A high NA optical path is designed to perform OCM and MPM while a low NA optical path is designed for the visible spectrum to navigate the endoscope to areas of interest and narrowband imaging. Different tests such as the reflectance profile of homogeneous epithelial tissue were performed to adjust the models properly. Light collection models for the different modalities were created and tested for efficiency. While it is challenging to evaluate the efficiency of multimodality endoscopes, the models ensure that the system is design for the expected light collection levels to provide detectable signal to work for the intended imaging.
Novel computer-based endoscopic camera
Rabinovitz, R.; Hai, N.; Abraham, Martin D.; Adler, Doron; Nissani, M.; Fridental, Ron; Vitsnudel, Ilia
1995-05-01
We have introduced a computer-based endoscopic camera which includes (a) unique real-time digital image processing to optimize image visualization by reducing over exposed glared areas and brightening dark areas, and by accentuating sharpness and fine structures, and (b) patient data documentation and management. The image processing is based on i Sight's iSP1000TM digital video processor chip and Adaptive SensitivityTM patented scheme for capturing and displaying images with wide dynamic range of light, taking into account local neighborhood image conditions and global image statistics. It provides the medical user with the ability to view images under difficult lighting conditions, without losing details `in the dark' or in completely saturated areas. The patient data documentation and management allows storage of images (approximately 1 MB per image for a full 24 bit color image) to any storage device installed into the camera, or to an external host media via network. The patient data which is included with every image described essential information on the patient and procedure. The operator can assign custom data descriptors, and can search for the stored image/data by typing any image descriptor. The camera optics has extended zoom range of f equals 20 - 45 mm allowing control of the diameter of the field which is displayed on the monitor such that the complete field of view of the endoscope can be displayed on all the area of the screen. All these features provide versatile endoscopic camera with excellent image quality and documentation capabilities.
Zaria Universal Oxygenator Holder phase I
Directory of Open Access Journals (Sweden)
Sunday Adoga Edaigbini
2014-01-01
Full Text Available Introduction: The conduct of cardiopulmonary bypass surgery requires the use of equipment and devices like the oxygenator. The oxygenator comes in different makes and each manufacturer customizes the carrier or ′holder′ of this device specific to their design. Aim: This paper presents an innovation designed to overcome the need to purchase a different holder for every oxygenator thereby cutting the cost. Materials and Methods: A sheet of iron measuring 1.9 cm (width × 0.1 cm (thickness was used to design the holder circular main frame. Another sheet measuring 2 cm (width × 0.6 cm (thickness × 24 cm (length was used to construct a V-shaped handle with the arms of the V attached to the main frame 7 cm apart. At the narrow base of the handle is a latch requiring two 13-gauge screws to attach the holder to the heart-lung machine. Within the circumference of the main frame are four T-shaped side arms which grip the oxygenator; located at 2, 5, 7 and 11 O′clock positions. The stem of the T consist of a 0.6 cm (thickness × 13 cm (length rod drilled through the main frame. The cross of the T consists of variable lengths of the same sheet as the mainframe attached to the stem by a screw mechanism. At the base of the T, is attached a circular handle (4 cm in diameter made of 0.4 cm iron rod. Result: An oxygenator holder which weighs 1.75 kg with a total length of 54 cm (the diameter of the mainframe is 30 cm. Its advantages include (i affordability, (ii materials are locally accessible, (iii versatility (iv reproducibility. The disadvantages include, (i it requires some time to fit, (ii caution is required in fitting the oxygenator to avoid breakage, (iii a spanner is required to lock the latch. Conclusion: The concept of a universal holder is pertinent, especially in resource poor environments to avoid purchasing a new holder whenever the usual oxygenator common to the centre is unavailable. This device is amenable to further modifications to
Tem holder for sample transfer under reaction conditions
DEFF Research Database (Denmark)
Damsgaard, Christian Danvad; Zandbergen, Henny W.; Wagner, Jakob Birkedal
Environmental transmission electron microscopy (ETEM) studies are usually performed using conventional sample holders in a dedicated ETEM [1] or in a traditional TEM by use of a dedicated high-pressure cell sample holder [2]. In both cases, the setup defines the conditions regarding gas, pressure......]. Furthermore, dedicated transfer holders have been used to transfer catalyst samples between reactor set-ups and TEM at room temperature in inert atmosphere [5]. To take the full advantage of complementary in situ techniques, transfer under reactions conditions is essential. This study introduces the in situ...... transfer concept by use of a dedicated TEM transfer holder capable of enclosing the sample in a gaseous environment at temperatures up to approx. 900C. By oxidation and reduction experiments of Cu nanoparticles it is shown possible to keep the reaction conditions during transfer outside the microscope...
Lexan Linear Shaped Charge Holder with Magnets and Backing Plate
Maples, Matthew W.; Dutton, Maureen L.; Hacker, Scott C.; Dean, Richard J.; Kidd, Nicholas; Long, Chris; Hicks, Robert C.
2013-01-01
A method was developed for cutting a fabric structural member in an inflatable module, without damaging the internal structure of the module, using linear shaped charge. Lexan and magnets are used in a charge holder to precisely position the linear shaped charge over the desired cut area. Two types of charge holders have been designed, each with its own backing plate. One holder cuts fabric straps in the vertical configuration, and the other charge holder cuts fabric straps in the horizontal configuration.
Breeding snow: an instrumented sample holder for simultaneous tomographic and thermal studies
International Nuclear Information System (INIS)
Pinzer, B; Schneebeli, M
2009-01-01
To study the recrystallization processes during temperature gradient metamorphism of snow, we developed a sample holder that allows applying well-defined and stable thermal gradients to a snow sample while it is scanned in an x-ray micro-tomograph. To this end, both the thermal insulation of the sample as well as image contrast and resolution of the tomography had to be optimized. We solved this conflict by using thin aluminum cylinders in combination with highly insulating foam. This design is light, does not corrupt image quality and provides very good thermal decoupling from the environment. The sample holder was instrumented to measure the effective conductivity of the snow sample and calibrated using five materials of known conductivity. Finite element simulations were consistent with the calibration measurements and gave insight into the internal temperature and heat flux fields. With this setup, geometric and thermal evolution of snow under realistic thermal boundary conditions like alternating temperature gradients can be measured
A Conceptual Design of Light-weighted Mobile Robot for the Integrity of SG Tubes in NPP
Energy Technology Data Exchange (ETDEWEB)
Seo, Yong Chil; Jeong, Kyung Min; Shin, Ho Chul; Lee, Sung Uk; Cho, Jae Wan; Choi, Young Soo; Kim, Seung Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Shin, Chun Sup; Park, Ki Tae [Korea Plant Serviceand Engineering, Busan (Korea, Republic of)
2010-10-15
Steam generators (SG) are among the most critical components of pressurized water Nuclear Power Plants (NPP). SG tubes must provide a reliable pressure boundary between the primary and secondary cooling water. It is because that any leakage from tube defects could result in the release of radioactivity to the environment. Thus degradations of steam generators tubes should be monitored and inspected periodically under nuclear regulatory. In-service inspections of SG tubes are carried out using eddy current test (ECT) and the defected tubes are usually plugged. Because the radioactivity in the internal of SG chambers limits free access of human worker, remote manipulators are required. In South Korea, Manipulators such as the Zetec SM series and the Westinghouse ROSA series have been used. Such manipulators are rigidly mounted to manways or tube sheets of SG. Confusions for the inspected tubes may occur from deflection of the manipulators. To reduce the deflections of the manipulators for covering the large working areas of tube sheets, sufficient rigidity is required and it leads to the increase of the weight. Such weight increase results in some difficulties for handling and more radiation exposure of human workers. Recently light-weighed mobile robots have been introduced by Westinghouse and Zetec. The robots can move keeping in contact with the tube sheets using devices which are commonly called cam-locks. They are easier to handle and provide no confusion for the position of the inspected tubes. But when the clamping forces are loosed accidently, they can be fall down and light repair works can be performed. This paper provides the design results for a light weighted mobile robot which is recently being developed in cooperation of our institutes
A Conceptual Design of Light-weighted Mobile Robot for the Integrity of SG Tubes in NPP
International Nuclear Information System (INIS)
Seo, Yong Chil; Jeong, Kyung Min; Shin, Ho Chul; Lee, Sung Uk; Cho, Jae Wan; Choi, Young Soo; Kim, Seung Ho; Shin, Chun Sup; Park, Ki Tae
2010-01-01
Steam generators (SG) are among the most critical components of pressurized water Nuclear Power Plants (NPP). SG tubes must provide a reliable pressure boundary between the primary and secondary cooling water. It is because that any leakage from tube defects could result in the release of radioactivity to the environment. Thus degradations of steam generators tubes should be monitored and inspected periodically under nuclear regulatory. In-service inspections of SG tubes are carried out using eddy current test (ECT) and the defected tubes are usually plugged. Because the radioactivity in the internal of SG chambers limits free access of human worker, remote manipulators are required. In South Korea, Manipulators such as the Zetec SM series and the Westinghouse ROSA series have been used. Such manipulators are rigidly mounted to manways or tube sheets of SG. Confusions for the inspected tubes may occur from deflection of the manipulators. To reduce the deflections of the manipulators for covering the large working areas of tube sheets, sufficient rigidity is required and it leads to the increase of the weight. Such weight increase results in some difficulties for handling and more radiation exposure of human workers. Recently light-weighed mobile robots have been introduced by Westinghouse and Zetec. The robots can move keeping in contact with the tube sheets using devices which are commonly called cam-locks. They are easier to handle and provide no confusion for the position of the inspected tubes. But when the clamping forces are loosed accidently, they can be fall down and light repair works can be performed. This paper provides the design results for a light weighted mobile robot which is recently being developed in cooperation of our institutes
Control of articulated snake robot under dynamic active constraints.
Kwok, Ka-Wai; Vitiello, Valentina; Yang, Guang-Zhong
2010-01-01
Flexible, ergonomically enhanced surgical robots have important applications to transluminal endoscopic surgery, for which path-following and dynamic shape conformance are essential. In this paper, kinematic control of a snake robot for motion stabilisation under dynamic active constraints is addressed. The main objective is to enable the robot to track the visual target accurately and steadily on deforming tissue whilst conforming to pre-defined anatomical constraints. The motion tracking can also be augmented with manual control. By taking into account the physical limits in terms of maximum frequency response of the system (manifested as a delay between the input of the manipulator and the movement of the end-effector), we show the importance of visual-motor synchronisation for performing accurate smooth pursuit movements. Detailed user experiments are performed to demonstrate the practical value of the proposed control mechanism.
Afterword: Robot Conceptualizations Between Continuity and Innovation
Directory of Open Access Journals (Sweden)
Leopoldina Fortunati
2013-01-01
Full Text Available The aim of this afterword is to discuss a topic that links all the papers presented in this special issue. This transversal topic is the forms of social robots. Firstly, social robots form is discussed in light of the forms of robotics we have inherited from the past. This includes the models of society that each of them embodied, as well as the social logic of the emotions connected to them. Secondly, social robots form is analyzed in light of the arrival in a new area for robotics, that of robots in the domestic sphere. Here, the system of filters created by the mass appropriation of information and communication technologies in the last two decades, has set the premise for a change of the social contract that has made social robot penetration possible. Whilst exploring the models and the meanings of social robots in the domestic sphere it emerges that robotics is following two different paths: one addressing the material part of housework (more traditional robotics and the other addressing the immaterial part of reproduction work (more innovative robotics. Finally, the paper analyzes the dematerialization process of social robotics that is still taking place, a practice that is defined herein as “ubiquitous social roboting.”
New endoscope shaft for endoscopic transsphenoidal pituitary surgery.
Lindert, E.J. van; Grotenhuis, J.A.
2005-01-01
OBJECTIVE: To describe a new endoscope shaft developed for suction-aspiration during endoscopic transsphenoidal pituitary surgery. METHODS: A custom-made shaft for a Wolf endoscope (Richard Wolf GmbH, Knittlingen, Germany) was developed with a height of 10 mm and a width of 5 mm, allowing an
Overview of robotic colorectal surgery: Current and future practical developments
Roy, Sudipta; Evans, Charles
2016-01-01
Minimal access surgery has revolutionised colorectal surgery by offering reduced morbidity and mortality over open surgery, while maintaining oncological and functional outcomes with the disadvantage of additional practical challenges. Robotic surgery aids the surgeon in overcoming these challenges. Uptake of robotic assistance has been relatively slow, mainly because of the high initial and ongoing costs of equipment but also because of limited evidence of improved patient outcomes. Advances in robotic colorectal surgery will aim to widen the scope of minimal access surgery to allow larger and more complex surgery through smaller access and natural orifices and also to make the technology more economical, allowing wider dispersal and uptake of robotic technology. Advances in robotic endoscopy will yield self-advancing endoscopes and a widening role for capsule endoscopy including the development of motile and steerable capsules able to deliver localised drug therapy and insufflation as well as being recharged from an extracorporeal power source to allow great longevity. Ultimately robotic technology may advance to the point where many conventional surgical interventions are no longer required. With respect to nanotechnology, surgery may eventually become obsolete. PMID:26981188
Practical aspects of the use of the X(2) holder for HRTEM-quality TEM sample preparation by FIB.
van Mierlo, Willem; Geiger, Dorin; Robins, Alan; Stumpf, Matthias; Ray, Mary Louise; Fischione, Paul; Kaiser, Ute
2014-12-01
The X(2) holder enables the effective production of thin, electron transparent samples for high-resolution transmission electron microscopy (HRTEM). Improvements to the X(2) holder for high-quality transmission electron microscopy (TEM) sample preparation are presented in this paper. We discuss the influence of backscattered electrons (BSE) from the sample holder in determining the lamella thickness in situ and demonstrate that a significant improvement in thickness determination can be achieved by comparatively simple means using the relative BSE intensity. We show (using Monte Carlo simulations) that by taking into account the finite collection angle of the electron backscatter detector, an approximately 20% underestimation of the lamella thickness in a silicon sample can be avoided. However, a correct thickness determination for light-element lamellas still remains a problem with the backscatter method; we introduce a more accurate method using the energy dispersive X-ray spectroscopy (EDX) signal for in situ thickness determination. Finally, we demonstrate how to produce a thin lamella with a nearly damage-free surface using the X(2) holder in combination with sub-kV polishing in the Fischione Instruments׳ NanoMill(®) TEM specimen preparation system. Copyright © 2014 Elsevier B.V. All rights reserved.
Robotic Y-V Plasty for Recalcitrant Bladder Neck Contracture.
Granieri, Michael A; Weinberg, Aaron C; Sun, Jeffrey Y; Stifleman, Michael; Zhao, Lee
2018-07-01
To demonstrate the technique and the outcomes of robot assisted Y-V plasty bladder neck reconstruction (RYVBNR). We present our technique for treatment of recalcitrant bladder neck contracture (BNC) in 7 patients who underwent RYVBNR at our institution between March 2016 and September 2017. Indication for the procedure was incomplete emptying, recurrent urinary tract infections, and dysuria. On follow-up, patients were assessed for clinical success by absence of infections, symptoms, and cystoscopic evaluation. Robotic assisted dissection is performed to open the space of Retzius and mobilize the bladder. The cystoscope is passed to the level of the BNC, and Firefly technology is used to localize the BNC. The BNC is incised anteriorly, and a V-shaped bladder flap is advanced into the BNC in a Y-V plasty fashion. We place a perioperative closed suction drain, which is removed before discharge, and a 22 Fr catheter, which that will be removed in the office at approximately 2 weeks. Six men developed recalcitrant BNCs and 1 developed a recalcitrant vesicourethral anastomotic stenosis. All patients had previously undergone an endoscopic procedure. Median time for last attempt at endoscopic management to robot-assisted bladder neck repair was 4.7 months. The average number of prior attempts at endoscopic management was 2. All patients underwent RYVBNR without conversion to open surgery. The median operative time was 240 minutes, estimated blood loss was 67 mL, and length of stay was 1 day. There were no intraoperative complications. Catheters were removed in the office at a median time of 15 days. At a median follow-up of 8 months, all cases were successful with no evidence of recurrence. Only 2 patients had persistent urinary incontinence at 1 pad per day. RYVBNR with a Y-V plasty is a feasible and effective technique for managing a difficult reconstructive problem. Copyright © 2018 Elsevier Inc. All rights reserved.
Robotic single-site pelvic lymphadenectomy.
Tateo, Saverio; Nozza, Arrigo; Del Pezzo, Chiara; Mereu, Liliana
2014-09-01
To examine the feasibility of performing pelvic lymphadenectomy with robotic single site approach. Recent papers described the feasibility of robotic-single site hysterectomy [1-3] for benign and malign pathologies but only with the development of new single site 5mm instruments as the bipolar forceps, robotic single site platform can be safely utilized also for lymphadenectomy. A 65 year-old, multiparous patient with a body mass index of 22.5 and diagnosed with well differentiated adenocarcinoma of the endometrium underwent a robotic single-site peritoneal washing, total hysterectomy, bilateral adnexectomy and pelvic lymphadenectomy. The procedure was performed using the da Vinci Si Surgical System (Intuitive Surgical, Sunnyvale, CA) through a single 2,5 cm umbilical incision, with a multi-channel system and two single site robotic 5mm instruments. A 3-dimensional, HD 8.5mm endoscope and a 5mm accessory instrument were also utilized. Type I lymphonodes dissection for external iliac and obturator regions was performed [4]. Total operative time was 210 min; incision, trocar placement and docking time occurring in 12 min. Total console time was 183 min, estimated blood loss was 50 ml, no intra-operative or post-operative complications occurred. Hospital discharge occurred on post operative day 2 and total number of lymphnodes removed was 33. Difficulties in term of instrument's clashing and awkward motions have been encountered. Robotic single-site pelvic lymphadenectomy using bipolar forceps and monopolar hook is feasible. New developments are needed to improve surgical ergonomics and additional studies should be performed to explore possible benefits of this procedure. Copyright © 2014 Elsevier Inc. All rights reserved.
Clinical endoscopic management and outcome of post-endoscopic sphincterotomy bleeding.
Directory of Open Access Journals (Sweden)
Wei-Chen Lin
Full Text Available Post-endoscopic sphincterotomy bleeding is a common complication of biliary sphincterotomy, and the incidence varies from 1% to 48%. It can be challenging to localize the bleeder or to administer various interventions through a side-viewing endoscope. This study aimed to evaluate the risk factors of post-endoscopic sphincterotomy bleeding and the outcome of endoscopic intervention therapies. We retrospectively reviewed the records of 513 patients who underwent biliary sphincterotomy in Mackay Memorial Hospital between 2011 and 2016. The blood biochemistry, comorbidities, indication for sphincterotomy, severity of bleeding, endoscopic features of bleeder, and type of endoscopic therapy were analyzed. Post-endoscopic sphincterotomy bleeding occurred in 65 (12.6% patients. Forty-five patients had immediate bleeding and 20 patients had delayed bleeding. The multivariate analysis of risk factors associated with post-endoscopic sphincterotomy bleeding were liver cirrhosis (P = 0.029, end-stage renal disease (P = 0.038, previous antiplatelet drug use (P<0.001, and duodenal ulcer (P = 0.023. The complications of pancreatitis and cholangitis were higher in the bleeding group, with statistical significance. Delayed bleeding occurred within 1 to 7 days (mean, 2.5 days, and 60% (12/20 of the patients received endoscopic evaluation. In the delayed bleeding group, the successful hemostasis rate was 71.4% (5/7, and 65% (13/20 of the patients had ceased bleeding without endoscopic hemostasis therapy. Comparison of different therapeutic modalities showed that cholangitis was higher in patients who received epinephrine spray (P = 0.042 and pancreatitis was higher in patients who received epinephrine injection and electrocoagulation (P = 0.041 and P = 0.039 respectively. Clinically, post-endoscopic sphincterotomy bleeding and further endoscopic hemostasis therapy increase the complication rate of pancreatitis and cholangitis. Realizing the effectiveness of each
Computational surgery and dual training computing, robotics and imaging
Bass, Barbara; Berceli, Scott; Collet, Christophe; Cerveri, Pietro
2014-01-01
This critical volume focuses on the use of medical imaging, medical robotics, simulation, and information technology in surgery. It offers a road map for computational surgery success, discusses the computer-assisted management of disease and surgery, and provides a rational for image processing and diagnostic. This book also presents some advances on image-driven intervention and robotics, as well as evaluates models and simulations for a broad spectrum of cancers as well as cardiovascular, neurological, and bone diseases. Training and performance analysis in surgery assisted by robotic systems is also covered. This book also: · Provides a comprehensive overview of the use of computational surgery and disease management · Discusses the design and use of medical robotic tools for orthopedic surgery, endoscopic surgery, and prostate surgery · Provides practical examples and case studies in the areas of image processing, virtual surgery, and simulation traini...
Barakat, Monique T; Girotra, Mohit; Huang, Robert J; Banerjee, Subhas
2018-02-06
Outbreaks of transmission of infection related to endoscopy despite reported adherence to reprocessing guidelines warrant scrutiny of all potential contributing factors. Recent reports from ambulatory surgery centers indicated widespread significant occult damage within endoscope working channels, raising concerns regarding the potential detrimental impact of this damage on the adequacy of endoscope reprocessing. We inspected working channels of all 68 endoscopes at our academic institution using a novel flexible inspection endoscope. Inspections were recorded and videos reviewed by 3 investigators to evaluate and rate channel damage and/or debris. Working channel rinsates were obtained from all endoscopes, and adenosine triphosphate (ATP) bioluminescence was measured. Overall endoscope working channel damage was rated as minimal and/or mild and was consistent with expected wear and tear (median 1.59 on our 5-point scale). Our predominant findings included superficial scratches (98.5%) and scratches with adherent peel (76.5%). No channel perforations, stains, or burns were detected. The extent of damage was not predicted by endoscope age. Minor punctate debris was common, and a few small drops of fluid were noted in 42.6% of endoscopes after reprocessing and drying. The presence of residual fluid predicted higher ATP bioluminescence values. The presence of visualized working channel damage or debris was not associated with elevated ATP bioluminescence values. The flexible inspection endoscope enables high-resolution imaging of endoscope working channels and offers endoscopy units an additional modality for endoscope surveillance, potentially complementing bacterial cultures and ATP values. Our study, conducted in a busy academic endoscopy unit, indicated predominately mild damage to endoscope working channels, which did not correlate with elevated ATP values. Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights
Szold, Amir; Bergamaschi, Roberto; Broeders, Ivo; Dankelman, Jenny; Forgione, Antonello; Langø, Thomas; Melzer, Andreas; Mintz, Yoav; Morales-Conde, Salvador; Rhodes, Michael; Satava, Richard; Tang, Chung-Ngai; Vilallonga, Ramon
2015-02-01
Following an extensive literature search and a consensus conference with subject matter experts the following conclusions can be drawn: 1. Robotic surgery is still at its infancy, and there is a great potential in sophisticated electromechanical systems to perform complex surgical tasks when these systems evolve. 2. To date, in the vast majority of clinical settings, there is little or no advantage in using robotic systems in general surgery in terms of clinical outcome. Dedicated parameters should be addressed, and high quality research should focus on quality of care instead of routine parameters, where a clear advantage is not to be expected. 3. Preliminary data demonstrates that robotic system have a clinical benefit in performing complex procedures in confined spaces, especially in those that are located in unfavorable anatomical locations. 4. There is a severe lack of high quality data on robotic surgery, and there is a great need for rigorously controlled, unbiased clinical trials. These trials should be urged to address the cost-effectiveness issues as well. 5. Specific areas of research should include complex hepatobiliary surgery, surgery for gastric and esophageal cancer, revisional surgery in bariatric and upper GI surgery, surgery for large adrenal masses, and rectal surgery. All these fields show some potential for a true benefit of using current robotic systems. 6. Robotic surgery requires a specific set of skills, and needs to be trained using a dedicated, structured training program that addresses the specific knowledge, safety issues and skills essential to perform this type of surgery safely and with good outcomes. It is the responsibility of the corresponding professional organizations, not the industry, to define the training and credentialing of robotic basic skills and specific procedures. 7. Due to the special economic environment in which robotic surgery is currently employed special care should be taken in the decision making process when
Highly dexterous 2-module soft robot for intra-organ navigation in minimally invasive surgery.
Abidi, Haider; Gerboni, Giada; Brancadoro, Margherita; Fras, Jan; Diodato, Alessandro; Cianchetti, Matteo; Wurdemann, Helge; Althoefer, Kaspar; Menciassi, Arianna
2018-02-01
For some surgical interventions, like the Total Mesorectal Excision (TME), traditional laparoscopes lack the flexibility to safely maneuver and reach difficult surgical targets. This paper answers this need through designing, fabricating and modelling a highly dexterous 2-module soft robot for minimally invasive surgery (MIS). A soft robotic approach is proposed that uses flexible fluidic actuators (FFAs) allowing highly dexterous and inherently safe navigation. Dexterity is provided by an optimized design of fluid chambers within the robot modules. Safe physical interaction is ensured by fabricating the entire structure by soft and compliant elastomers, resulting in a squeezable 2-module robot. An inner free lumen/chamber along the central axis serves as a guide of flexible endoscopic tools. A constant curvature based inverse kinematics model is also proposed, providing insight into the robot capabilities. Experimental tests in a surgical scenario using a cadaver model are reported, demonstrating the robot advantages over standard systems in a realistic MIS environment. Simulations and experiments show the efficacy of the proposed soft robot. Copyright © 2017 John Wiley & Sons, Ltd.
Endoscopic vision-based tracking of multiple surgical instruments during robot-assisted surgery.
Ryu, Jiwon; Choi, Jaesoon; Kim, Hee Chan
2013-01-01
Robot-assisted minimally invasive surgery is effective for operations in limited space. Enhancing safety based on automatic tracking of surgical instrument position to prevent inadvertent harmful events such as tissue perforation or instrument collisions could be a meaningful augmentation to current robotic surgical systems. A vision-based instrument tracking scheme as a core algorithm to implement such functions was developed in this study. An automatic tracking scheme is proposed as a chain of computer vision techniques, including classification of metallic properties using k-means clustering and instrument movement tracking using similarity measures, Euclidean distance calculations, and a Kalman filter algorithm. The implemented system showed satisfactory performance in tests using actual robot-assisted surgery videos. Trajectory comparisons of automatically detected data and ground truth data obtained by manually locating the center of mass of each instrument were used to quantitatively validate the system. Instruments and collisions could be well tracked through the proposed methods. The developed collision warning system could provide valuable information to clinicians for safer procedures. © 2012, Copyright the Authors. Artificial Organs © 2012, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Wang, Lin; Cao, Xin; Ren, Qingyun; Chen, Xueli; He, Xiaowei
2018-05-01
Cerenkov luminescence imaging (CLI) is an imaging method that uses an optical imaging scheme to probe a radioactive tracer. Application of CLI with clinically approved radioactive tracers has opened an opportunity for translating optical imaging from preclinical to clinical applications. Such translation was further improved by developing an endoscopic CLI system. However, two-dimensional endoscopic imaging cannot identify accurate depth and obtain quantitative information. Here, we present an imaging scheme to retrieve the depth and quantitative information from endoscopic Cerenkov luminescence tomography, which can also be applied for endoscopic radio-luminescence tomography. In the scheme, we first constructed a physical model for image collection, and then a mathematical model for characterizing the luminescent light propagation from tracer to the endoscopic detector. The mathematical model is a hybrid light transport model combined with the 3rd order simplified spherical harmonics approximation, diffusion, and radiosity equations to warrant accuracy and speed. The mathematical model integrates finite element discretization, regularization, and primal-dual interior-point optimization to retrieve the depth and the quantitative information of the tracer. A heterogeneous-geometry-based numerical simulation was used to explore the feasibility of the unified scheme, which demonstrated that it can provide a satisfactory balance between imaging accuracy and computational burden.
Systems workplace for endoscopic surgery.
Irion, K M; Novak, P
2000-01-01
With the advent of minimally invasive surgery (MIS) a decade ago, the requirements for operating rooms (OR) and their equipment have been increased. Compared with conventional open surgery, the new endoscopic techniques require additional tools. Television systems, for video-assisted image acquisition and visualisation, including cameras, monitors and light systems, as well as insufflators, pumps, high-frequency units, lasers and motorised therapy units, are nowadays usually made available on carts during endoscopic surgery. In conjunction with a set of endoscopic instruments, these high-tech units allow new operating techniques to be performed. The benefit for patients has become clear in recent years; however, the technical complexity of OR has also increased considerably. To minimise this problem for the OR personnel, the MIS concept 'OR1' (Operating Room 1) was developed and implemented. OR1 is a fully functional and integrated multi-speciality surgical suite for MIS. The centrepieces of the OR1 are the Storz Communication Bus (SCB) and the advanced image and data archiving system (Aida) from Karl Storz, Tuttlingen, Germany. Both components allow monitoring, access and networking of the MIS equipment and other OR facilities, as well as the acquisition, storage and display of image, patient and equipment data during the endoscopic procedure. A central user interface allows efficient, simplified operation and online clinical images. Due to the system integration, the handling of complex equipment is considerably simplified, logistical procedures in the OR are improved, procedure times are shorter and, particularly noteworthy, operative risk can be reduced through simplified device operation.
Self-recalibration of a robot-assisted structured-light-based measurement system.
Xu, Jing; Chen, Rui; Liu, Shuntao; Guan, Yong
2017-11-10
The structured-light-based measurement method is widely employed in numerous fields. However, for industrial inspection, to achieve complete scanning of a work piece and overcome occlusion, the measurement system needs to be moved to different viewpoints. Moreover, frequent reconfiguration of the measurement system may be needed based on the size of the measured object, making the self-recalibration of extrinsic parameters indispensable. To this end, this paper proposes an automatic self-recalibration and reconstruction method, wherein a robot arm is employed to move the measurement system for complete scanning; the self-recalibration is achieved using fundamental matrix calculations and point cloud registration without the need for an accurate calibration gauge. Experimental results demonstrate the feasibility and accuracy of our method.
Anor, Tomer; Madsen, Joseph R; Dupont, Pierre
2011-05-09
We propose a novel systematic approach to optimizing the design of concentric tube robots for neurosurgical procedures. These procedures require that the robot approach specified target sites while navigating and operating within an anatomically constrained work space. The availability of preoperative imaging makes our approach particularly suited for neurosurgery, and we illustrate the method with the example of endoscopic choroid plexus ablation. A novel parameterization of the robot characteristics is used in conjunction with a global pattern search optimization method. The formulation returns the design of the least-complex robot capable of reaching single or multiple target points in a confined space with constrained optimization metrics. A particular advantage of this approach is that it identifies the need for either fixed-curvature versus variable-curvature sections. We demonstrate the performance of the method in four clinically relevant examples.
Optical Robotics in Mesoscopia
DEFF Research Database (Denmark)
Glückstad, Jesper
2012-01-01
With light’s miniscule momentum, shrinking robotics down to the micro-scale regime creates opportunities for exploiting optical forces and torques in advanced actuation and control at the nano- and micro-scale dimensions. Advancing light-driven nano- or micro-robotics requires the optimization...... of optimized shapes in the micro-robotics structures [1]. We designed different three-dimensional microstructures and had them fabricated by two-photon polymerization at BRC Hungary. These microstructures were then handled by our proprietary BioPhotonics Workstation to show proof-of-principle 3 demonstrations...
Design and analysis on robotic arm for serving hazard container
Razali, Zol Bahri; Kader, Mohamed Mydin M. Abdul; Yi, Khoo Zern; Daud, Mohd Hisam
2017-09-01
This paper presents about design, analyses development and fabrication of robotic arm for sorting multi-material. The major problem that urges the initiation of the project is the fact that manufacturing industry is growing at relatively faster rate. Most of the company produce high load robotic arm. Less company creates light weight, and affordable robotic arm. As the result, light weight and affordable robot is developing to cover this issue. Plastic material was used to construct the body of the robotic arm, and an optical sensor was implemented to provide basic recognition of object to be carried. The robotic arm used five servomotors for overall operation; four for its joints, and one for the gripping mechanism. The gripper was designed and fabricated using Perspex due to the light weight and high strength of the material. The operation of the robotic arm was governed by Basic Stamp programming sequence and the device was expected to differentiate material and other objects based on reflective theory, and perform subsequent operations afterwards. The SolidWorks was used to model the detail design of the robotic arm, and to simulate the motion of the device.
Mu, Nan; Wang, Kun; Xie, Zexiao; Ren, Ping
2017-05-01
To realize online rapid measurement for complex workpieces, a flexible measurement system based on an articulated industrial robot with a structured light sensor mounted on the end-effector is developed. A method for calibrating the system parameters is proposed in which the hand-eye transformation parameters and the robot kinematic parameters are synthesized in the calibration process. An initial hand-eye calibration is first performed using a standard sphere as the calibration target. By applying the modified complete and parametrically continuous method, we establish a synthesized kinematic model that combines the initial hand-eye transformation and distal link parameters as a whole with the sensor coordinate system as the tool frame. According to the synthesized kinematic model, an error model is constructed based on spheres' center-to-center distance errors. Consequently, the error model parameters can be identified in a calibration experiment using a three-standard-sphere target. Furthermore, the redundancy of error model parameters is eliminated to ensure the accuracy and robustness of the parameter identification. Calibration and measurement experiments are carried out based on an ER3A-C60 robot. The experimental results show that the proposed calibration method enjoys high measurement accuracy, and this efficient and flexible system is suitable for online measurement in industrial scenes.
Endoscopic root canal treatment.
Moshonov, Joshua; Michaeli, Eli; Nahlieli, Oded
2009-10-01
To describe an innovative endoscopic technique for root canal treatment. Root canal treatment was performed on 12 patients (15 teeth), using a newly developed endoscope (Sialotechnology), which combines an endoscope, irrigation, and a surgical microinstrument channel. Endoscopic root canal treatment of all 15 teeth was successful with complete resolution of all symptoms (6-month follow-up). The novel endoscope used in this study accurately identified all microstructures and simplified root canal treatment. The endoscope may be considered for use not only for preoperative observation and diagnosis but also for active endodontic treatment.
Playware Explorations in Robot Art
DEFF Research Database (Denmark)
Lund, Henrik Hautop; Pagliarini, Luigi
2013-01-01
We describe the upcoming art field termed robot art. Describing our group contribution to the world of robot art, a brief excursion on the importance of the underlying principles, of the context, of the message and its semiotic is also provided, case by case, together with few hints on the recent...... history of such a discipline, under the light of an artistic perspective. Therefore, the aim of the paper is to try to summarize the main characteristics that might classify ro-bot art as a unique and innovative discipline, and to track down some of the principles by which a robotic artifact can...
Khashab, Mouen A; Kumbhari, Vivek; Tieu, Alan H; El Zein, Mohamad H; Ismail, Amr; Ngamruengphong, Saowanee; Singh, Vikesh K; Kalloo, Anthony N; Clarke, John O; Stein, Ellen M
2017-01-01
Several uncontrolled studies comparing peroral endoscopic myotomy (POEM) and Heller myotomy have demonstrated equivalent short-term efficacy and safety. However, no data exists rergarding the cost of POEM and how it compares to that of robotic Heller myotomy (RHM). The primary aim of this study was to compare the inpatient charges incurred in patients who underwent POEM or RHM for the treatment of achalasia. A retrospective single center review was conducted among 52 consecutive POEM patients (2012-2014) and 52 consecutive RHM patients (2009-2014). All RHM procedures included a Toupet fundoplication and were performed via a transabdominal approach. All POEM procedures were performed by a gastroenterologist in the endoscopy unit. Clinical response was defined by improvement of symptoms and decrease in Eckardt stage to ≤I. All procedural and facility charges were obtained from review of the hospital finance records. There was no difference between POEM and RHM with regards to age, gender, symptom duration, achalasia subtype, manometry findings, or Eckardt symptom stage. There was no significant difference in the rate of adverse events (19.2% vs 9.6%, P = 0.26) or the length of stay (1.9 vs. 2.3, P = 0.18) between both groups. Clinical response rate of patients in the POEM groups was similar to that in the RHM group (94.3% vs. 88.5%, P = 0.48). POEM incurred significantly less total charges compared to LHM ($14481 vs. $17782, P = 0.02). POEM when performed in an endoscopy unit was similar in efficacy and safety to RHM. However, POEM was associated with significant cost savings ($3301/procedure).
Direct target NOTES: prospective applications for next generation robotic platforms.
Atallah, S; Hodges, A; Larach, S W
2018-05-01
A new era in surgical robotics has centered on alternative access to anatomic targets and next generation designs include flexible, single-port systems which follow circuitous rather than straight pathways. Such systems maintain a small footprint and could be utilized for specialized operations based on direct organ target natural orifice transluminal endoscopic surgery (NOTES), of which transanal total mesorectal excision (taTME) is an important derivative. During two sessions, four direct target NOTES operations were conducted on a cadaveric model using a flexible robotic system to demonstrate proof-of-concept of the application of a next generation robotic system to specific types of NOTES operations, all of which required removal of a direct target organ through natural orifice access. These four operations were (a) robotic taTME, (b) robotic transvaginal hysterectomy in conjunction with (c) robotic transvaginal salpingo-oophorectomy, and in an ex vivo model, (d) trans-cecal appendectomy. Feasibility was demonstrated in all cases using the Flex ® Robotic System with Colorectal Drive. During taTME, the platform excursion was 17 cm along a non-linear path; operative time was 57 min for the transanal portion of the dissection. Robotic transvaginal hysterectomy was successfully completed in 78 min with transvaginal extraction of the uterus, although laparoscopic assistance was required. Robotic transvaginal unilateral salpingo-oophorectomy with transvaginal extraction of the ovary and fallopian tube was performed without laparoscopic assistance in 13.5 min. In an ex vivo model, a robotic trans-cecal appendectomy was also successfully performed for the purpose of demonstrating proof-of-concept only; this was completed in 24 min. A flexible robotic system has the potential to access anatomy along circuitous paths, making it a suitable platform for direct target NOTES. The conceptual operations posed could be considered suitable for next generation robotics once
Improvements in appliance holders
International Nuclear Information System (INIS)
Chapman, J.E.
1977-01-01
Reference is made to appliance holders for locating tools, instruments, etc. in operative relationship to workpieces and accessible through passageways of restricted transverse dimensions. The appliance holder described comprises an elongated external frame provided with transversely, outwardly expanding frictional gripping means in two longitudinally spaced sets and with a ring of spur teeth. An inner elongated frame is held within the external frame in two longitudinally spaced rotary bearings and carries a spur wheel which engages the ring of the spur teeth. A motor is arranged to rotate the spur wheel and hence the inner frame in relation to the external frame. A carriage is carried by the inner frame, longitudinally movable by a motor in relation thereto, and a further carriage is mounted on this first carriage. This second cariage is transversely movable in relation to the inner frame and is provided with a face plate for attachment of tools, instruments, etc. A motor is mounted on the first carriage for moving the second carriage. (U.K.)
Design and control of MR haptic master/slave robot system for minimally invasive surgery
Uhm, Chang-Ho; Nguyen, Phoung Bac; Choi, Seung-Bok
2013-04-01
In this work, magnetorheological (MR) haptic master and slave robot for minimally invasive surgery (MIS) have been designed and tested. The proposed haptic master consists of four actuators; three MR brakes featuring gimbal structure for 3-DOF rotation motion(X, Y and Z axes) and one MR linear actuator for 1-DOF translational motion. The proposed slave robot which is connected with the haptic master has vertically multi- joints, and it consists of four DC servomotors; three for positioning endoscope and one for spinning motion. We added a fixed bar with a ball joint on the base of the slave for the endoscope position at the patient's abdomen to maintain safety. A gimbal structure at the end of the slave robotic arm for the last joint rotates freely with respect to the pivot point of the fixed bar. This master-slave system runs as if a teleoperation system through TCP/IP connection, programmed by LabVIEW. In order to achieve the desired position trajectory, a proportional-integral-derivative (PID) controller is designed and implemented. It has been demonstrated that the effective tracking control performances for the desired motion are well achieved and presented in time domain. At last, an experiment in virtual environments is undertaken to investigate the effectiveness of the MR haptic master device for MIS system.
A Miniature Robot for Retraction Tasks under Vision Assistance in Minimally Invasive Surgery
Directory of Open Access Journals (Sweden)
Giuseppe Tortora
2014-03-01
Full Text Available Minimally Invasive Surgery (MIS is one of the main aims of modern medicine. It enables surgery to be performed with a lower number and severity of incisions. Medical robots have been developed worldwide to offer a robotic alternative to traditional medical procedures. New approaches aimed at a substantial decrease of visible scars have been explored, such as Natural Orifice Transluminal Endoscopic Surgery (NOTES. Simple surgical tasks such as the retraction of an organ can be a challenge when performed from narrow access ports. For this reason, there is a continuous need to develop new robotic tools for performing dedicated tasks. This article illustrates the design and testing of a new robotic tool for retraction tasks under vision assistance for NOTES. The retraction robots integrate brushless motors to enable additional degrees of freedom to that provided by magnetic anchoring, thus improving the dexterity of the overall platform. The retraction robot can be easily controlled to reach the target organ and apply a retraction force of up to 1.53 N. Additional degrees of freedom can be used for smooth manipulation and grasping of the organ.
Designing the robot inclusive space challenge
Directory of Open Access Journals (Sweden)
Rajesh Elara Mohan
2015-11-01
Full Text Available A novel robotic challenge, namely the robot inclusive spaces (RIS challenge, is proposed in this paper, which is a cross disciplinary and design focused initiative. It aims to foster the roboticists, architects, and designers towards realizing robot friendly social spaces. Contrary to conventional robotics competitions focusing on designing robots and its component technologies, robot inclusive spaces challenge adopts an interdisciplinary “design for robots” strategy to overcome the traditional research problem in real world deployments of social robots. In order to realize the RIS, various architectural elements must be adapted including: design principles for inclusive spaces, lighting schemes, furniture choices and arrangement, wall and floor surfaces, pathways among others. This paper introduces the format and design principles of RIS challenge, presents a first run of the challenge, and gives the corresponding analysis.
The role of robotic surgical system in the management of vascular disease.
Lin, Judith C
2013-10-01
The evolution of minimally invasive treatment for aneurysms and occlusive disease has led to the development of endovascular, laparoscopic, and robot-assisted techniques. This article reviews the current literature on the clinical use of robotic surgical systems in the treatment of patients with aneurysms and occlusive disease. A MEDLINE search was performed using the keywords "robotic, vascular, AND surgery." All pertinent articles concerning the use of the robotic surgical system on aneurysms and occlusive disease were reviewed. The author's personal experience consisted of a retrospective review of a prospectively maintained confidential database on all procedures performed with the da Vinci(®) surgical system. Several robot-assisted laparoscopic series on the treatment of aortic disease were identified, including review articles of potential clinical applications in hybrid, laparoscopic vascular, and endovascular treatments for vascular patients using robotic technology. The use of computer-enhanced or robotic technology as a sole modality for bypass of occlusive disease and repair of abdominal aortic, splenic, and renal aneurysms was described in case series with satisfactory patient outcomes. Current robotic endovascular technology was also described. Minimally invasive techniques using endovascular, laparoscopic, or robot-assisted technology have revolutionized the treatment of aortoiliac, splanchnic, and renal aneurysms and occlusive disease. However, robot-assisted techniques for aortic disease may involve a learning curve and increased operating times. Although endovascular therapy is preferred because of faster recovery, this preference for improved short-term outcomes will be balanced with the superiority and durability of robot-assisted endoscopic methods as comparable to open surgery. Copyright © 2013 Elsevier Inc. All rights reserved.
30 CFR 250.1010 - General requirements for pipeline right-of-way holders.
2010-07-01
... United States or its lessees or right-of-way holders, as the case may be, the full value of all damages...). The right-of-way holder shall make available all records relative to the design, construction... site. Furthermore, the holder is responsible for accidents or damages which might occur as a result of...
Broadband sample holder for microwave spectroscopy of superconducting qubits
International Nuclear Information System (INIS)
Averkin, A. S.; Karpov, A.; Glushkov, E.; Abramov, N.; Shulga, K.; Huebner, U.; Il'ichev, E.; Ustinov, A. V.
2014-01-01
We present a practical design and implementation of a broadband sample holder suitable for microwave experiments with superconducting integrated circuits at millikelvin temperatures. Proposed design can be easily integrated in standard dilution cryostats, has flat pass band response in a frequency range from 0 to 32 GHz, allowing the RF testing of the samples with substrate size up to 4 × 4 mm 2 . The parasitic higher modes interference in the holder structure is analyzed and prevented via design considerations. The developed setup can be used for characterization of superconducting parametric amplifiers, bolometers, and qubits. We tested the designed sample holder by characterizing of a superconducting flux qubit at 20 mK temperature
Integrated biophotonics in endoscopic oncology
Muguruma, Naoki; DaCosta, Ralph S.; Wilson, Brian C.; Marcon, Norman E.
2009-02-01
Gastrointestinal endoscopy has made great progress during last decade. Diagnostic accuracy can be enhanced by better training, improved dye-contrast techniques method, and the development of new image processing technologies. However, diagnosis using conventional endoscopy with white-light optical imaging is essentially limited by being based on morphological changes and/or visual attribution: hue, saturation and intensity, interpretation of which depends on the endoscopist's eye and brain. In microlesions in the gastrointestinal tract, we still rely ultimately on the histopathological diagnosis from biopsy specimens. Autofluorescence imaging system has been applied for lesions which have been difficult to morphologically recognize or are indistinct with conventional endoscope, and this approach has potential application for the diagnosis of dysplastic lesions and early cancers in the gastrointestinal tract, supplementing the information from white light endoscopy. This system has an advantage that it needs no administration of a photosensitive agent, making it suitable as a screening method for the early detection of neoplastic tissues. Narrow band imaging (NBI) is a novel endoscopic technique which can distinguish neoplastic and non-neoplastic lesions without chromoendoscopy. Magnifying endoscopy in combination with NBI has an obvious advantage, namely analysis of the epithelial pit pattern and the vascular network. This new technique allows a detailed visualization in early neoplastic lesions of esophagus, stomach and colon. However, problems remain; how to combine these technologies in an optimum diagnostic strategy, how to apply them into the algorithm for therapeutic decision-making, and how to standardize several classifications surrounding them. 'Molecular imaging' is a concept representing the most novel imaging methods in medicine, although the definition of the word is still controversial. In the field of gastrointestinal endoscopy, the future of
Robotic removal of eroded vaginal mesh into the bladder.
Macedo, Francisco Igor B; O'Connor, Jeffrey; Mittal, Vijay K; Hurley, Patrick
2013-11-01
Vaginal mesh erosion into the bladder after midurethral sling procedure or cystocele repair is uncommon, with only a few cases having been reported in the literature. The ideal surgical management is still controversial. Current options for removal of eroded mesh include: endoscopic, transvaginal or abdominal (either open or laparoscopic) approaches. We, herein, present the first case of robotic removal of a large eroded vaginal mesh into the bladder and discuss potential benefits and limitations of the technique. © 2013 The Japanese Urological Association.
Multilevel stake holder consensus building in radioactive waste management
International Nuclear Information System (INIS)
Dreimanis, Andrejs
2008-01-01
Full text: The increased demand of our society to its quality of life, global security and environmental safety as well as to observing a basic ethical principle of equity have advanced our attitude towards the recent proposals to develop shared multinational projects in the use of nuclear energy technologies, in particular, to: a) Siting of shared deep repositories for high-level radioactive waste (RW) and spent nuclear fuel safe disposal. In turn, arrangement of multinational facilities requires to gain more complex consensus between all involved parties. Method: We propose an interdisciplinary synergetic approach to multilevel consensus building for siting and construction of shared multinational repositories for RW deep disposal, based on self-organization (SO) of various stake holders, chaos and fuzziness concepts as well as Ashby principle of requisite variety. In the siting of a multi-national repository there appears an essential novel component of stake holder consensus building, namely: to reach consent - political, social, economic, ecological - among international partners, in addition to solving the whole set of intra-national consensus building items. An entire partnering country is considered as a national stake holder, represented by the national government, being faced to simultaneous seeking an upward (international) and a downward (intra-national) consensus in a psychologically stressed environment, having possibly diverse political, economic and social interests. Main Results: Following inferences about building of multilevel consensus are developed: 1) The basis of synergetic approach to stake holder interaction - informational SO, by forming a knowledge-creating stake holder community via cooperation and competition among individuals, public bodies/groups, companies, institutions; 2) Building of international stake holder consensus could be promoted by activating and diversifying multilateral interactions between intra- and international stake
Robotic laparoscopic surgery: cost and training.
Amodeo, A; Linares Quevedo, A; Joseph, J V; Belgrano, E; Patel, H R H
2009-06-01
The advantages of minimally invasive surgery are well accepted. Shorter hospital stays, decreased postoperative pain, rapid return to preoperative activity, decreased postoperative ileus, and preserved immune function are among the benefits of the laparoscopic approach. However, the instruments of laparoscopy afford surgeons limited precision and poor ergonomics, and their use is associated with a significant learning curve and the amount of time and energy necessary to develop and maintain such advanced laparoscopic skills is not insignificant. The robotic surgery allows all laparoscopists to perform advanced laparoscopic procedures with greater ease. The potential advantages of surgical robotic systems include making advanced laparoscopic surgical procedures accessible to surgeons who do not have advanced video endoscopic training and broadening the scope of surgical procedures that can be performed using the laparoscopic method. The wristed instruments, x10 magnifications, tremor filtering, scaling of movements and three-dimensional view allow the urologist to perform the intricate dissection and anastomosis with high precision. The robot is not, however, without significant disadvantages as compared with traditional laparoscopy. These include greater expense and consumption of operating room resources such as space and the availability of skilled technical staff, complete elimination of tactile feedback, and more limited options for trocar placement. The current cost of the da Vinci system is $ 1.2 million and annual maintenance is $ 138000. Many studies suggest that depreciation and maintenance costs can be minimised if the number of robotic cases is increased. The high cost of purchasing and maintaining the instruments of the robotic system is one of its many disadvantages. The availability of the robotic systems to only a limited number of centres reduces surgical training opportunities. Hospital administrators and surgeons must define the reasons for
LC-lens array with light field algorithm for 3D biomedical applications
Huang, Yi-Pai; Hsieh, Po-Yuan; Hassanfiroozi, Amir; Martinez, Manuel; Javidi, Bahram; Chu, Chao-Yu; Hsuan, Yun; Chu, Wen-Chun
2016-03-01
In this paper, liquid crystal lens (LC-lens) array was utilized in 3D bio-medical applications including 3D endoscope and light field microscope. Comparing with conventional plastic lens array, which was usually placed in 3D endoscope or light field microscope system to record image disparity, our LC-lens array has higher flexibility of electrically changing its focal length. By using LC-lens array, the working distance and image quality of 3D endoscope and microscope could be enhanced. Furthermore, the 2D/3D switching ability could be achieved if we turn off/on the electrical power on LClens array. In 3D endoscope case, a hexagonal micro LC-lens array with 350um diameter was placed at the front end of a 1mm diameter endoscope. With applying electric field on LC-lens array, the 3D specimen would be recorded as from seven micro-cameras with different disparity. We could calculate 3D construction of specimen with those micro images. In the other hand, if we turn off the electric field on LC-lens array, the conventional high resolution 2D endoscope image would be recorded. In light field microscope case, the LC-lens array was placed in front of the CMOS sensor. The main purpose of LC-lens array is to extend the refocusing distance of light field microscope, which is usually very narrow in focused light field microscope system, by montaging many light field images sequentially focusing on different depth. With adjusting focal length of LC-lens array from 2.4mm to 2.9mm, the refocusing distance was extended from 1mm to 11.3mm. Moreover, we could use a LC wedge to electrically shift the optics axis and increase the resolution of light field.
Freeze Protection in Gas Holders
DEFF Research Database (Denmark)
Hjorth, Poul G.; Duursma, Gail
In cold weather, the water seals of gasholders need protection from freez- ing to avoid compromising the seal. These holders have a large reservoir of “tank water” at the base which is below ground. At present freeze- protection is achieved by external heating of the seal water which...
A triple axes multiple target holder assembly
International Nuclear Information System (INIS)
Tribedi, L.C.; Narvekar, S.D.; Pillay, R.G.; Tandon, P.N.
1993-01-01
We have designed and fabricated a rotatable target holder assembly capable of accommodating 27 targets. The target foils are mounted along two concentric circles on a ss wheel. On the outer circle 18 targets can be mounted each 20deg apart, and on the inner circle the remaining targets are positioned each 40deg apart. The self supporting or carbon backed targets are mounted on thin frames and are placed concentrically at the targets are mounted on thin frames and are placed concentrically at the target position on the wheel. Three degrees of freedom are provided to the target holder assembly. (author). 1 fig
Kajiwara, Naohiro; Kato, Yasufumi; Hagiwara, Masaru; Kakihana, Masatoshi; Ohira, Tatsuo; Kawate, Norihiko; Ikeda, Norihiko
2018-04-20
To discuss the cost-benefit performance (CBP) and establish a medical fee system for robotic-assisted thoracic surgery (RATS) under the Japanese National Health Insurance System (JNHIS), which is a system not yet firmly established. All management steps for RATS are identical, such as preoperative and postoperative management. This study examines the CBP based on medical fees of RATS under the JNHIS introduced in 2016. Robotic-assisted laparoscopic prostatectomy (RALP) and robotic-assisted partial nephrectomy (RAPN) now receive insurance reimbursement under the category of use of support devices for endoscopic surgery ($5420 and $3485, respectively). If the same standard amount were to be applied to RATS, institutions would need to perform at least 150 or 300 procedures thoracic operation per year to show a positive CBP ($317 per procedure as same of RALP and $130 per procedure as same of RAPN, respectively). Robotic surgery in some areas receives insurance reimbursement for its "supportive" use for endoscopic surgery as for RALP and RAPN. However, at present, it is necessary to perform da Vinci Surgical System Si (dVSi) surgery at least 150-300 times in a year in a given institution to prevent a deficit in income.
Endoscopic laser treatment for rectosigmoid villous adenoma: factors effecting the results
Brunetaud, Jean Marc; Maunoury, Vincent; Cochelard, Dominique; Boniface, Brigitte
1994-12-01
This present work reports the long term results after endoscopic laser treatment in 474 patients with benign rectosigmoid villous adenomas revealed by biopsy. Two types of wavelength were used: The 1.06 micrometers infrared light from the Nd:YAG laser and the green light from the argon laser or the Nd:YAG frequency doubled laser. In some patients, both wavelengths were used. Treatment was completed in 415 patients. Total tumor destruction was obtained in 92.8% of them, a carcinoma was detected in 6.5% on biopsy specimens obtained during laser treatment, and benign villous tissue persisted in 0.7%. During the average 30 mo. follow up period of the patients with total tumor destruction, 18% had a tumor recurrence. Treatment was well tolerated with a 1.8% complication rate (one perforation, one hemorrhage, and 7 stenosis requiring dilatation). Because treatment is long and difficult and cancer rate is high, endoscopic laser should be limited in patients with a circumferential villous adenoma to nonsurgical candidates. The risk of complication after surgery (some being fatal) has to be balanced against the risk of undetected carcinoma in the other patients and the indication for endoscopic laser treatment should be discussed case by case.
Tang, Chih-Yuan; Huang, Rong-Nan; Kuo-Huang, Ling-Long; Kuo, Tai-Chih; Yang, Ya-Yun; Lin, Ching-Yeh; Jane, Wann-Neng; Chen, Shiang-Jiuun
2012-02-01
A pre-cryogenic holder (cryo-holder) facilitating cryo-specimen observation under a conventional scanning electron microscope (SEM) is described. This cryo-holder includes a specimen-holding unit (the stub) and a cryogenic energy-storing unit (a composite of three cylinders assembled with a screw). After cooling, the cryo-holder can continue supplying cryogenic energy to extend the observation time for the specimen in a conventional SEM. Moreover, the cryogenic energy-storing unit could retain appropriate liquid nitrogen that can evaporate to prevent frost deposition on the surface of the specimen. This device is proved feasible for various tissues and cells, and can be applied to the fields of both biology and material science. We have employed this novel cryo-holder for observation of yeast cells, trichome, and epidermal cells in the leaf of Arabidopsis thaliana, compound eyes of insects, red blood cells, filiform papillae on the surface of rat tongue, agar medium, water molecules, penicillium, etc. All results suggested that the newly designed cryo-holder is applicable for cryo-specimen observation under a conventional SEM without cooling system. Most importantly, the design of this cryo-holder is simple and easy to operate and could adapt a conventional SEM to a plain type cryo-SEM affordable for most laboratories. Copyright © 2011 Wiley Periodicals, Inc.
Visual perception system and method for a humanoid robot
Wells, James W. (Inventor); Mc Kay, Neil David (Inventor); Chelian, Suhas E. (Inventor); Linn, Douglas Martin (Inventor); Wampler, II, Charles W. (Inventor); Bridgwater, Lyndon (Inventor)
2012-01-01
A robotic system includes a humanoid robot with robotic joints each moveable using an actuator(s), and a distributed controller for controlling the movement of each of the robotic joints. The controller includes a visual perception module (VPM) for visually identifying and tracking an object in the field of view of the robot under threshold lighting conditions. The VPM includes optical devices for collecting an image of the object, a positional extraction device, and a host machine having an algorithm for processing the image and positional information. The algorithm visually identifies and tracks the object, and automatically adapts an exposure time of the optical devices to prevent feature data loss of the image under the threshold lighting conditions. A method of identifying and tracking the object includes collecting the image, extracting positional information of the object, and automatically adapting the exposure time to thereby prevent feature data loss of the image.
Failure analysis of vise jaw holders for hacksaw machine
Directory of Open Access Journals (Sweden)
Essam Ali Al-Bahkali
2018-01-01
Full Text Available Failure analysis in mechanical components has been investigated in many studies in the last few years. Failure analysis and prevention are important functions in all engineering disciplines. Materials engineers are often the lead role in the analysis of failures, where a component or product fails in service or if a failure occurs during manufacturing or production processing. In any case, one must determine the cause of the failure to prevent future occurrences and/or to improve the performance of the device, component or structure. For example, the vise jaw holders of hacksaws can break due to accidental heavy loads or machine misuse. The parts that break are the stationary and movable vise jaw holders and the connecter power screw between the holders. To investigate the failure of these components, a three-dimensional finite element model for stress analysis was performed. First, the analysis identified the broken components of the hacksaw machine. In addition, the type of materials of the broken parts was identified, a CAD model was built, and the hacksaw mechanism was analyzed to determine the accurate applied loads on the broken parts. After analyzing the model using Abaqus CAE software, the results showed that the location of the high stresses was identical with the high-stress locations in the original, broken parts. Furthermore, the power screw was subjected to a high load, which deformed the power screw. Also, the stationary vise jaw holder was broken by impact because it was not touched by the power screw until the movable vise jaw holder broke. A conclusion is drawn from the failure analysis and a way to improve the design of the broken parts is suggested.
Research on the tool holder mode in high speed machining
Zhenyu, Zhao; Yongquan, Zhou; Houming, Zhou; Xiaomei, Xu; Haibin, Xiao
2018-03-01
High speed machining technology can improve the processing efficiency and precision, but also reduce the processing cost. Therefore, the technology is widely regarded in the industry. With the extensive application of high-speed machining technology, high-speed tool system has higher and higher requirements on the tool chuck. At present, in high speed precision machining, several new kinds of clip heads are as long as there are heat shrinkage tool-holder, high-precision spring chuck, hydraulic tool-holder, and the three-rib deformation chuck. Among them, the heat shrinkage tool-holder has the advantages of high precision, high clamping force, high bending rigidity and dynamic balance, etc., which are widely used. Therefore, it is of great significance to research the new requirements of the machining tool system. In order to adapt to the requirement of high speed machining precision machining technology, this paper expounds the common tool holder technology of high precision machining, and proposes how to select correctly tool clamping system in practice. The characteristics and existing problems are analyzed in the tool clamping system.
Kinematics Analysis of End Effector for Carrier Robot of Feeding Broiler Chicken System
Syam, Rafiuddin; Arsyad, Hairul; Bauna, Ruslan; Renreng, Ilyas; Bakhri, Syaiful
2018-02-01
The demand for commodities, especially Broiler chicken farms are increasing, the volume of feed requirements Broiler chickens increased with age up to the age of 30-57 days required feed 3,829 grams/day/head, so if the chicken population is 3,000 needed transporting feed 11 487 kg/day, This research aims to produce a robot capable of transporting feed in the top of the cage by using a control system so as to make efficient use of manpower. Design robot performed using software design three-dimensional Solidworks2010, process of making the robot is started with the design manufacture three (3) units of mechanical systems (mechanical system for holder feed, mechanical systems for lifter feed and mechanical systems for transporting feed), then do the design process framework as a component buffer so that the mechanical system will work properly and safely when the robot operates. Furthermore, the manufacture of electronic circuits and control are using Arduino Mega microcontroller. After assembling all components mechanical systems and installation of electronic systems and control, then experiments to evaluate the performance of the robot have been made. The results of experiments showed that all components work well according to plan, in particular the speed and acceleration of end effector motion so it can hold and release the feed well. This strongly supports the robots perform tasks in accordance with the intent, i.e., holding, lifting and moving feed.
Image acquisition in laparoscopic and endoscopic surgery
Gill, Brijesh S.; Georgeson, Keith E.; Hardin, William D., Jr.
1995-04-01
Laparoscopic and endoscopic surgery rely uniquely on high quality display of acquired images, but a multitude of problems plague the researcher who attempts to reproduce such images for educational purposes. Some of these are intrinsic limitations of current laparoscopic/endoscopic visualization systems, while others are artifacts solely of the process used to acquire and reproduce such images. Whatever the genesis of these problems, a glance at current literature will reveal the extent to which endoscopy suffers from an inability to reproduce what the surgeon sees during a procedure. The major intrinsic limitation to the acquisition of high-quality still images from laparoscopic procedures lies in the inability to couple directly a camera to the laparoscope. While many systems have this capability, this is useful mostly for otolaryngologists, who do not maintain a sterile field around their scopes. For procedures in which a sterile field must be maintained, one trial method has been to use a beam splitter to send light both to the still camera and the digital video camera. This is no solution, however, since this results in low quality still images as well as a degradation of the image that the surgeon must use to operate, something no surgeon tolerates lightly. Researchers thus must currently rely on other methods for producing images from a laparoscopic procedure. Most manufacturers provide an optional slide or print maker that provides a hardcopy output from the processed composite video signal. The results achieved from such devices are marginal, to say the least. This leaves only one avenue for possible image production, the videotape record of an endoscopic or laparoscopic operation. Video frame grabbing is at least a problem to which industry has applied considerable time and effort to solving. Our own experience with computerized enhancement of videotape frames has been very promising. Computer enhancement allows the researcher to correct several of the
Excitation-scanning hyperspectral imaging system for microscopic and endoscopic applications
Mayes, Sam A.; Leavesley, Silas J.; Rich, Thomas C.
2016-04-01
Current microscopic and endoscopic technologies for cancer screening utilize white-light illumination sources. Hyper-spectral imaging has been shown to improve sensitivity while retaining specificity when compared to white-light imaging in both microscopy and in vivo imaging. However, hyperspectral imaging methods have historically suffered from slow acquisition times due to the narrow bandwidth of spectral filters. Often minutes are required to gather a full image stack. We have developed a novel approach called excitation-scanning hyperspectral imaging that provides 2-3 orders of magnitude increased signal strength. This reduces acquisition times significantly, allowing for live video acquisition. Here, we describe a preliminary prototype excitation-scanning hyperspectral imaging system that can be coupled with endoscopes or microscopes for hyperspectral imaging of tissues and cells. Our system is comprised of three subsystems: illumination, transmission, and imaging. The illumination subsystem employs light-emitting diode arrays to illuminate at different wavelengths. The transmission subsystem utilizes a unique geometry of optics and a liquid light guide. Software controls allow us to interface with and control the subsystems and components. Digital and analog signals are used to coordinate wavelength intensity, cycling and camera triggering. Testing of the system shows it can cycle 16 wavelengths at as fast as 1 ms per cycle. Additionally, more than 18% of the light transmits through the system. Our setup should allow for hyperspectral imaging of tissue and cells in real time.
van der Meijden, O A J; Schijven, M P
2009-06-01
Virtual reality (VR) as surgical training tool has become a state-of-the-art technique in training and teaching skills for minimally invasive surgery (MIS). Although intuitively appealing, the true benefits of haptic (VR training) platforms are unknown. Many questions about haptic feedback in the different areas of surgical skills (training) need to be answered before adding costly haptic feedback in VR simulation for MIS training. This study was designed to review the current status and value of haptic feedback in conventional and robot-assisted MIS and training by using virtual reality simulation. A systematic review of the literature was undertaken using PubMed and MEDLINE. The following search terms were used: Haptic feedback OR Haptics OR Force feedback AND/OR Minimal Invasive Surgery AND/OR Minimal Access Surgery AND/OR Robotics AND/OR Robotic Surgery AND/OR Endoscopic Surgery AND/OR Virtual Reality AND/OR Simulation OR Surgical Training/Education. The results were assessed according to level of evidence as reflected by the Oxford Centre of Evidence-based Medicine Levels of Evidence. In the current literature, no firm consensus exists on the importance of haptic feedback in performing minimally invasive surgery. Although the majority of the results show positive assessment of the benefits of force feedback, results are ambivalent and not unanimous on the subject. Benefits are least disputed when related to surgery using robotics, because there is no haptic feedback in currently used robotics. The addition of haptics is believed to reduce surgical errors resulting from a lack of it, especially in knot tying. Little research has been performed in the area of robot-assisted endoscopic surgical training, but results seem promising. Concerning VR training, results indicate that haptic feedback is important during the early phase of psychomotor skill acquisition.
Right-Arm Robotic-Aided-Therapy with the Light-Exoskeleton: A General Overview
Lugo-Villeda , Luis I.; Frisoli , Antonio; Sotgiu , Edoardo; Greco , Giovanni; Bergamasco , Massimo; Lugo-Villeda , Luis ,
2010-01-01
Part 7: Robots and Manipulation; International audience; Rehabilitation robotics applications and their developments have been spreading out as consequences of the actual needs in the human activities of daily living (ADL). Exoskeletons for rehabilitation are one of them, whose intrinsic characteristics are quite useful for applications where repetitive, robustness and accurate performance are a must. As a part of robotic-mediated-rehabilitation programme into the worldwide, the exoskeletons ...
Directory of Open Access Journals (Sweden)
Shintaro Fujihara
2014-01-01
Full Text Available Endoscopic submucosal dissection (ESD is accepted as a minimally invasive treatment for colorectal cancer. However, due to technical difficulties and an increased rate of complications, ESD is not widely used in the colorectum. In some cases, endoscopic treatment alone is insufficient for disease control, and laparoscopic surgery is required. The combination of laparoscopic surgery and endoscopic resection represents a new frontier in cancer treatment. Recent developments in advanced polypectomy and minimally invasive surgical techniques will enable surgeons and endoscopists to challenge current practice in colorectal cancer treatment. Endoscopic full-thickness resection (EFTR of the colon offers the potential to decrease the postoperative morbidity and mortality associated with segmental colectomy while enhancing the diagnostic yield compared to current endoscopic techniques. However, closure is necessary after EFTR and natural transluminal endoscopic surgery (NOTES. Innovative methods and new devices for EFTR and suturing are being developed and may potentially change traditional paradigms to achieve minimally invasive surgery for colorectal cancer. The present paper aims to discuss the complementary role of ESD and the future development of EFTR. We focus on the possibility of achieving EFTR using the ESD method and closing devices.
Endoscopic surgery and photodynamic therapy for behign and malignant neoplasms of colon
Directory of Open Access Journals (Sweden)
А. А. Razzhivina
2013-01-01
Full Text Available The review of literature for current methods of endoscopic treatment for colon epithelial neoplasms is represented. Such types of endoscopic interventions as loop electroresection, submucosal dissection, coagulation and destruction of tumors and combination of several options depending on efficiency of previous therapy is analyzed. Limitations of every method, its special aspects and possible complications are described. Special focus is on specifics of neoplasms for which selected methods may be the most effective. Thus, hot biopsy and destruction using high-energy laser is efficient for small flat neoplasms, endoscopic electroexcision – far small pedunculated lesions, and fragmentation is adequate for exophytic tumors more than 2.0 cm. Long-term results of endoscopic treatment, recurrence rates after different options are represented. The literature for photodynamic therapy consists mostly articles about development (on pre-clenecal stage of new photosensitizers which are effective for colon cancer, new methods of treatment including combination with hyperthermia in low-dose light irradiation etc. The literature data shows the prospectivity of subsequent developments in this field.
Kanamori, Katsuhiro
2016-07-01
An endoscopic image processing technique for enhancing the appearance of microstructures on translucent mucosae is described. This technique employs two pairs of co- and cross-polarization images under two different linearly polarized lights, from which the averaged subtracted polarization image (AVSPI) is calculated. Experiments were then conducted using an acrylic phantom and excised porcine stomach tissue using a manual experimental setup with ring-type lighting, two rotating polarizers, and a color camera; better results were achieved with the proposed method than with conventional color intensity image processing. An objective evaluation method that uses texture analysis was developed and used to evaluate the enhanced microstructure images. This paper introduces two types of online, rigid-type, polarimetric endoscopic implementations using a polarized ring-shaped LED and a polarimetric camera. The first type uses a beam-splitter-type color polarimetric camera, and the second uses a single-chip monochrome polarimetric camera. Microstructures on the mucosa surface were enhanced robustly with these online endoscopes regardless of the difference in the extinction ratio of each device. These results show that polarimetric endoscopy using AVSPI is both effective and practical for hardware implementation.
Laser trapping and spatial light modulators
DEFF Research Database (Denmark)
Glückstad, Jesper
2012-01-01
INVITED: Robotics at the macro-scale typically uses light for carrying information in machine vision for monitoring and feedback in intelligent robotic guidance systems. With light’s miniscule momentum, shrinking robots down to the micro-scale regime creates opportunities for exploiting optical f...
Lathe tool bit and holder for machining fiberglass materials
Winn, L. E. (Inventor)
1972-01-01
A lathe tool and holder combination for machining resin impregnated fiberglass cloth laminates is described. The tool holder and tool bit combination is designed to accommodate a conventional carbide-tipped, round shank router bit as the cutting medium, and provides an infinite number of cutting angles in order to produce a true and smooth surface in the fiberglass material workpiece with every pass of the tool bit. The technique utilizes damaged router bits which ordinarily would be discarded.
Structural analysis of 177-FA redesigned surveillance specimen holder tube
International Nuclear Information System (INIS)
Pryor, C.W.; Thoren, D.E.; Vames, G.J.; Harris, R.J.
1976-08-01
Because of in-service operational problems, the surveillance specimen holder tubes described in B and W topical report BAW-10051 have been redesigned. This report describes the new design and structural analysis for normal operation and upset loading conditions. The results of the analysis demonstrate the adequacy of the new surveillance specimen holder tubes for their design life of 40 years
The application of manipulator robot for nuclear power plant maintenance
International Nuclear Information System (INIS)
Fujita, Jun; Onishi, Ken
2009-01-01
In the maintenance works at nuclear power plant, robots are used because of high radiation, narrow space and underwater work. In light of manufacture period, cost and reliability, various maintenance works are requested to be done by one robot. As one of the solutions, we developed manipulator robots for the access of specialized tools. This study shows manipulator robots developed by MHI, application example to maintenance works and effectiveness of manipulator robots. When robotization of maintenance works are considered, manipulator technology is very effective solution means. The manipulator technologies in this study are able to apply to robotization needed under radiation environment. (author)
7 CFR 1463.105 - Base quota levels for eligible quota holders.
2010-01-01
... 7 Agriculture 10 2010-01-01 2010-01-01 false Base quota levels for eligible quota holders. 1463.105 Section 1463.105 Agriculture Regulations of the Department of Agriculture (Continued) COMMODITY... TRANSITION PROGRAM Tobacco Transition Payment Program § 1463.105 Base quota levels for eligible quota holders...
Ogawa, Yoshikazu; Nakata, Yusuke; Tominaga, Teiji
2014-01-01
Modern medical management requires constant quality improvement of the various instruments used for surgical procedures. Higher quality, less complicated handling, and reduced maintenance are all desirable qualities. However, any improvements in instrumentation require that surgeons must clearly understand the application of the device by adherence to the manufacturer's instructions. The weakness of this one-way information flow depends on the low interest among medical personnel for post-purchase reassessment. Service industries have research departments to investigate the post-purchase behavior of customers, and service recovery is considered essential to retain customers after service failure. All service providers can suffer service failures, and even the best providers may make errors in delivering service. Such an approach has been increasingly adopted in the risk management at medical institutions. We report our clinical trials of the post-purchase reassessment and product improvement of surgical instrumentation. Medical personnel reassessed the use of a newly developed endoscope holder based on the manufacturer's manual and made recommendations for possible improvements, which were examined by the manufacturer. Simple but important improvement was achieved for reducing the instability and uncertainty of instrument fixation. This bi-directional post-purchase communication between medical personnel and manufacturers can improve risk management in medical institutions.
Endoscopic submucosal dissection
DEFF Research Database (Denmark)
Pimentel-Nunes, Pedro; Dinis-Ribeiro, Mário; Ponchon, Thierry
2015-01-01
evidence). 2 ESGE recommends endoscopic resection with a curative intent for visible lesions in Barrett's esophagus (strong recommendation, moderate quality evidence). ESD has not been shown to be superior to EMR for excision of mucosal cancer, and for that reason EMR should be preferred. ESD may...... RECOMMENDATIONS: 1 ESGE recommends endoscopic en bloc resection for superficial esophageal squamous cell cancers (SCCs), excluding those with obvious submucosal involvement (strong recommendation, moderate quality evidence). Endoscopic mucosal resection (EMR) may be considered in such lesions when...
Endoscopic Devices for Obesity.
Sampath, Kartik; Dinani, Amreen M; Rothstein, Richard I
2016-06-01
The obesity epidemic, recognized by the World Health Organization in 1997, refers to the rising incidence of obesity worldwide. Lifestyle modification and pharmacotherapy are often ineffective long-term solutions; bariatric surgery remains the gold standard for long-term obesity weight loss. Despite the reported benefits, it has been estimated that only 1% of obese patients will undergo surgery. Endoscopic treatment for obesity represents a potential cost-effective, accessible, minimally invasive procedure that can function as a bridge or alternative intervention to bariatric surgery. We review the current endoscopic bariatric devices including space occupying devices, endoscopic gastroplasty, aspiration technology, post-bariatric surgery endoscopic revision, and obesity-related NOTES procedures. Given the diverse devices already FDA approved and in development, we discuss the future directions of endoscopic therapies for obesity.
Mistry, N; Coulson, C; George, A
2017-11-01
Digital and mobile device technology in healthcare is a growing market. The introduction of the endoscope-i, the world's first endoscopic mobile imaging system, allows the acquisition of high definition images of the ear, nose and throat (ENT). The system combines the e-i Pro camera app with a bespoke engineered endoscope-i adaptor which fits securely onto the iPhone or iPod touch. Endoscopic examination forms a salient aspect of the ENT work-up. The endoscope-i therefore provides a mobile and compact alternative to the existing bulky endoscopic systems currently in use which often restrict the clinician to the clinic setting. Areas covered: This article gives a detailed overview of the endoscope-i system together with its applications. A review and comparison of alternative devices on the market offering smartphone adapted endoscopic viewing systems is also presented. Expert commentary: The endoscope-i fulfils unmet needs by providing a compact, highly portable, simple to use endoscopic viewing system which is cost-effective and which makes use of smartphone technology most clinicians have in their pocket. The system allows real-time feedback to the patient and has the potential to transform the way that healthcare is delivered in ENT as well as having applications further afield.
21 CFR 892.1920 - Radiographic head holder.
2010-04-01
...) Identification. A radiographic head holder is a device intended to position the patient's head during a... device is also exempt from the current good manufacturing practice requirements of the quality system...
Miniature surgical robots in the era of NOTES and LESS: dream or reality?
Zygomalas, Apollon; Kehagias, Ioannis; Giokas, Konstantinos; Koutsouris, Dimitrios
2015-02-01
Laparoscopy is an established method for the treatment of numerous surgical conditions. Natural orifice transluminal endoscopic surgery (NOTES) is a novel surgical technique that uses the natural orifices of the human body as entrances to the abdominal cavity. An alternative concept of minimally invasive approach to the abdominal cavity is to insert all the laparoscopic instruments through ports using a single small incision on the abdominal wall. A suggested name for this technique is laparoendoscopic single-site surgery (LESS). Considering the technical difficulties in NOTES and LESS and the progress in informatics and robotics, the use of robots seems ideal. The aim of this study is to investigate if there is at present, a realistic possibility of using miniature robots in NOTES or LESS in daily clinical practice. An up-to-date review on in vivo surgical miniature robots is made. A Web-based research of the English literature up to March 2013 using PubMed, Scopus, and Google Scholar as search engines was performed. The development of in vivo miniature robots for use in NOTES or LESS is a reality with great advancements, potential advantages, and possible application in minimally invasive surgery in the future. However, true totally NOTES or LESS procedures on humans using miniature robots either solely or as assistance, remain a dream at present. © The Author(s) 2014.
Equipment for linking source stand and film holder carriage
International Nuclear Information System (INIS)
Fajt, P.; Zeman, M.
1987-01-01
A device is described for precision link-up of a source stand provided with a spring-loaded cam and a film holder carriage provided with an arm with catches. The catches are mechanically connected to a control device firmly connected to the bottom part of the film holder carriage arm. The cam whose extended part is slidably mounted in the cover guide is secured in position with springs fitted from both sides. The control device consists of an electromagnet with armature connected to the control device pull-rod. The pull-rod provides mechanical connection of the catches and the control device. Upon pressing the pushbutton, the catches automatically engage the film holder cariage arm so that the motorized source stand operates without connection to the carriage. This significantly facilitates the operation of the equipment and reduces physical effort of the technician. The most significant advantage is the possibility of immediate change in operation mode. (J.B.). 5 figs
Endoscopic management of colorectal adenomas.
Meier, Benjamin; Caca, Karel; Fischer, Andreas; Schmidt, Arthur
2017-01-01
Colorectal adenomas are well known precursors of invasive adenocarcinoma. Colonoscopy is the gold standard for adenoma detection. Colonoscopy is far more than a diagnostic tool, as it allows effective treatment of colorectal adenomas. Endoscopic resection of colorectal adenomas has been shown to reduce the incidence and mortality of colorectal cancer. Difficult resection techniques are available, such as endoscopic mucosal resection, endoscopic submucosal dissection and endoscopic full-thickness resection. This review aims to provide an overview of the different endoscopic resection techniques and their indications, and summarizes the current recommendations in the recently published guideline of the European Society of Gastrointestinal Endoscopy.
Brittle Fracture Behaviors of Large Die Holders Used in Hot Die Forging
Directory of Open Access Journals (Sweden)
Weifang Zhang
2017-05-01
Full Text Available Brittle fracture of large forging equipment usually leads to catastrophic consequences. To avoid this kind of accident, the brittle fracture behaviors of a large die holder were studied by simulating the practical application. The die holder is used on the large die forging press, and it is made of 55NiCrMoV7 hot-work tool steel. Detailed investigations including mechanical properties analysis, metallographic observation, fractography, transmission electron microscope (TEM analysis and selected area electron diffraction (SAED were conducted. The results reveal that the material generated a large quantity of large size polyhedral M23C6 (M: Fe and Cr mainly and elongated M3C (M: Fe mainly carbides along the martensitic lath boundaries when the die holder was recurrently tempered and water-cooled at 250 °C during the service. The large size carbides lead to the material embrittlement and impact toughness degradation, and further resulted in the brittle fracture of the die holder. Therefore, the operation specification must be emphasized to avoid the die holder being cooled by using water, which is aimed at accelerating the cooling.
Funk, Emily; Goldenberg, David; Goyal, Neerav
2017-06-01
Current management of laryngeal malignancies is associated with significant morbidity. Application of minimally invasive transoral techniques may reduce the morbidity associated with traditional procedures. The purpose of this study was to present our investigation of the utility of a novel flexible robotic system for transoral supraglottic laryngectomy and total laryngectomy. Transoral total laryngectomy and transoral supraglottic laryngectomy were performed in cadaveric specimens using the Flex Robotic System (Medrobotics, Raynham, MA). All procedures were completed successfully in the cadaveric models. The articulated endoscope allowed for access to the desired surgical site. Flexible instruments enabled an atraumatic approach and allowed for precise surgical technique. Access to deep anatomic structures remains problematic using current minimally invasive robotic approaches. Improvements in visualization and access to the laryngopharyngeal complex offered by this system may improve surgical applications to the larynx. This study demonstrates the technical feasibility using the Flex Robotic System for transoral robotic supraglottic laryngectomy and total laryngectomy. © 2017 Wiley Periodicals, Inc. Head Neck 39: 1218-1225, 2017. © 2017 Wiley Periodicals, Inc.
Homeostasis lighting control based on relationship between lighting environment and human behavior
Ueda, Risa; Mita, Akira
2015-03-01
Although each person has own preferences, living spaces which can respond to various preferences and needs have not become reality. Focusing on the lighting environments which influence on the impression of living spaces, this research aims to offer comfortable lighting environments for each resident by a flexible control. This research examines the relationship between lighting environments and human behaviors considering colored lights. In accord with the relationship, this research proposes an illuminance-color control system which flexibly changes spatial environments responding to human conditions. Firstly, the psychological evaluation was conducted in order to build human models for various environments. As a result, preferred lighting environments for each examinee were determined for particular behaviors. Moreover, satisfaction levels of lighting environments were calculated by using seven types of impression of the environments as parameters. The results were summarized as human models. Secondly, this research proposed "Homeostasis Lighting Control System", which employs the human models. Homeostasis lighting control system embodies the algorithm of homeostasis, which is one of the functions of the physiological adaptation. Human discomfort feelings are obtained automatically by the sensor agent robot. The system can offer comfortable lighting environments without controlling environments by residents autonomously based on the information from the robot. This research takes into accounts both illuminance and color. The robot communicates with the server which contains human models, then the system corresponds to individuals. Combining these three systems, the proposed system can effectively control the lighting environment. At last, the feasibility of the proposed system was verified by simulation experiments.
Robot-assisted automatic ultrasound calibration.
Aalamifar, Fereshteh; Cheng, Alexis; Kim, Younsu; Hu, Xiao; Zhang, Haichong K; Guo, Xiaoyu; Boctor, Emad M
2016-10-01
Ultrasound (US) calibration is the process of determining the unknown transformation from a coordinate frame such as the robot's tooltip to the US image frame and is a necessary task for any robotic or tracked US system. US calibration requires submillimeter-range accuracy for most applications, but it is a time-consuming and repetitive task. We provide a new framework for automatic US calibration with robot assistance and without the need for temporal calibration. US calibration based on active echo (AE) phantom was previously proposed, and its superiority over conventional cross-wire phantom-based calibration was shown. In this work, we use AE to guide the robotic arm motion through the process of data collection; we combine the capability of the AE point to localize itself in the frame of the US image with the automatic motion of the robotic arm to provide a framework for calibrating the arm to the US image automatically. We demonstrated the efficacy of the automated method compared to the manual method through experiments. To highlight the necessity of frequent ultrasound calibration, it is demonstrated that the calibration precision changed from 1.67 to 3.20 mm if the data collection is not repeated after a dismounting/mounting of the probe holder. In a large data set experiment, similar reconstruction precision of automatic and manual data collection was observed, while the time was reduced by 58 %. In addition, we compared ten automatic calibrations with ten manual ones, each performed in 15 min, and showed that all the automatic ones could converge in the case of setting the initial matrix as identity, while this was not achieved by manual data sets. Given the same initial matrix, the repeatability of the automatic was [0.46, 0.34, 0.80, 0.47] versus [0.42, 0.51, 0.98, 1.15] mm in the manual case for the US image four corners. The submillimeter accuracy requirement of US calibration makes frequent data collections unavoidable. We proposed an automated
Autonomous Mobile Robot That Can Read
Directory of Open Access Journals (Sweden)
Létourneau Dominic
2004-01-01
Full Text Available The ability to read would surely contribute to increased autonomy of mobile robots operating in the real world. The process seems fairly simple: the robot must be capable of acquiring an image of a message to read, extract the characters, and recognize them as symbols, characters, and words. Using an optical Character Recognition algorithm on a mobile robot however brings additional challenges: the robot has to control its position in the world and its pan-tilt-zoom camera to find textual messages to read, potentially having to compensate for its viewpoint of the message, and use the limited onboard processing capabilities to decode the message. The robot also has to deal with variations in lighting conditions. In this paper, we present our approach demonstrating that it is feasible for an autonomous mobile robot to read messages of specific colors and font in real-world conditions. We outline the constraints under which the approach works and present results obtained using a Pioneer 2 robot equipped with a Pentium 233 MHz and a Sony EVI-D30 pan-tilt-zoom camera.
Sample holder for studying temperature dependent particle guiding
International Nuclear Information System (INIS)
Bereczky, R.J.; Toekesi, K.; Kowarik, G.; Aumayr, F.
2011-01-01
Complete text of publication follows. The so called guiding effect is a complex process involving the interplay of a large number of charged particles with a solid. Although many research groups joined this field and carried out various experiments with insulator capillaries many details of the interactions are still unknown. We investigated the temperature dependence of the guiding since it opens new possibilities both for a fundamental understanding of the guiding phenomenon and for applications. For the temperature dependent guiding experiments a completely new heatable sample holder was designed. We developed and built such a heatable sample holder to make accurate and reproducible studies of the temperature dependence of the ion guiding effect possible. The target holder (for an exploded view see Fig. 1) consists of two main parts, the front and the back plates. The two plates of the sample holder, which function as an oven, are made of copper. These parts surround the capillary in order to guarantee a uniform temperature along the whole tube. The temperature of the copper parts is monitored by a K-Type thermocouple. Stainless steel coaxial heaters surrounding the oven are used for heating. The heating power up to a few watts is regulated by a PID controller. Cooling of the capillary is achieved by a copper feed-through connected to a liquid nitrogen bath outside the UHV chamber. This solution allows us to change the temperature of the sample from -30 deg C up to 90 deg C. Our experiments with this newly developed temperature regulated capillary holder show that the glass temperature (i.e. conductivity) can be used to control the guiding properties of the glass capillary and adjust the conditions from guiding at room temperature to simple geometrical transmission at elevated temperatures. This holds the promise to investigate the effect of conductivity on particle transport (build-up and removal of charge patches) through capillaries in more details
14 CFR 26.33 - Holders of type certificates: Fuel tank flammability.
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Holders of type certificates: Fuel tank... Tank Flammability § 26.33 Holders of type certificates: Fuel tank flammability. (a) Applicability. This... part 25 of this chapter. (2) Exception. This paragraph (b) does not apply to— (i) Fuel tanks for which...
Huang, Shih-Wei; Chen, Shih-Hua; Chen, Weichung; Wu, I.-Chen; Wu, Ming Tsang; Kuo, Chie-Tong; Wang, Hsiang-Chen
2016-03-01
This study presents a method to identify early esophageal cancer within endoscope using hyperspectral imaging technology. The research samples are three kinds of endoscopic images including white light endoscopic, chromoendoscopic, and narrow-band endoscopic images with different stages of pathological changes (normal, dysplasia, dysplasia - esophageal cancer, and esophageal cancer). Research is divided into two parts: first, we analysis the reflectance spectra of endoscopic images with different stages to know the spectral responses by pathological changes. Second, we identified early cancerous lesion of esophagus by principal component analysis (PCA) of the reflectance spectra of endoscopic images. The results of this study show that the identification of early cancerous lesion is possible achieve from three kinds of images. In which the spectral characteristics of NBI endoscopy images of a gray area than those without the existence of the problem the first two, and the trend is very clear. Therefore, if simply to reflect differences in the degree of spectral identification, chromoendoscopic images are suitable samples. The best identification of early esophageal cancer is using the NBI endoscopic images. Based on the results, the use of hyperspectral imaging technology in the early endoscopic esophageal cancer lesion image recognition helps clinicians quickly diagnose. We hope for the future to have a relatively large amount of endoscopic image by establishing a hyperspectral imaging database system developed in this study, so the clinician can take this repository more efficiently preliminary diagnosis.
Learning endoscopic resection in the esophagus
van Vilsteren, Frederike G. I.; Pouw, Roos E.; Herrero, Lorenza Alvarez; Bisschops, Raf; Houben, Martin; Peters, Frans T. M.; Schenk, B. E.; Weusten, Bas L. A. M.; Schoon, Erik J.; Bergman, Jacques J. G. H. M.
Background: Endoscopic resection is the cornerstone of endoscopic management of esophageal early neoplasia. However, endoscopic resection is a complex technique requiring knowledge and expertise. Our aims were to identify the most important learning points in performing endoscopic resection in a
Boonnuch, Wiroon; Akaraviputh, Thawatchai; Nino, Carnivale; Yiengpruksawan, Anusak; Christiano, Arthur Andrew
2011-01-01
A 59-year-old man with metastatic an esophageal tumor from hepatocellular carcinoma (HCC) presented with progressive dysphagia. He had undergone liver transplantation for HCC three and a half years prevously. At presentation, his radiological and endoscopic examinations suggested a submucosal tumor in the lower esophagus, causing a luminal stricture. We performed complete resection of the esophageal metastases and esophagogastrostomy reconstruction using the da Vinci robotic system. Recovery was uneventful and he was been doing well 2 mo after surgery. α-fetoprotein level decreased from 510 ng/mL to 30 ng/mL postoperatively. During the follow-up period, he developed a recurrent esophageal stricture at the anastomosis site and this was successfully treated by endoscopic esophageal dilatation. PMID:21765971
2012-11-20
... Activities: Holders or Containers Which Enter the United States Duty Free AGENCY: U.S. Customs and Border... information collection requirement concerning the Holders or Containers which Enter the United States Duty... concerning the following information collection: Title: Holders or Containers which Enter the United States...
An X-ray diffractometer specimen holder for use with reactive and toxic materials
International Nuclear Information System (INIS)
Huyton, A.; Munden, A.B.
1979-04-01
An X-ray diffractometer specimen holder has been designed for analysis of reactive sodium compounds which will satisfactorily seal the sample from the atmosphere. The holder can be readily filled in a glove-box and is easily transported for mounting on a vertical Philips PW 1051 X-ray diffractometer. It is considered that this holder could also be applied to a wide range of other reactive and toxic materials, e.g. plutonium or its compounds. (author)
Zhou, Pinghong; Yao, Liqing; Qin, Xinyu; Xu, Meidong; Zhong, Yunshi; Chen, Weifeng
2009-02-01
The objective of this study was to determine the efficacy and safety of endoscopic submucosal dissection for locally recurrent colorectal cancer after previous endoscopic mucosal resection. A total of 16 patients with locally recurrent colorectal lesions were enrolled. A needle knife, an insulated-tip knife and a hook knife were used to resect the lesion along the submucosa. The rate of the curative resection, procedure time, and incidence of complications were evaluated. Of 16 lesions, 15 were completely resected with endoscopic submucosal dissection, yielding an en bloc resection rate of 93.8 percent. Histologic examination confirmed that lateral and basal margins were cancer-free in 14 patients (87.5 percent). The average procedure time was 87.2 +/- 60.7 minutes. None of the patients had immediate or delayed bleeding during or after endoscopic submucosal dissection. Perforation in one patient (6.3 percent) was the only complication and was managed conservatively. The mean follow-up period was 15.5 +/- 6.8 months; none of the patients experienced lesion residue or recurrence. Endoscopic submucosal dissection appears to be effective for locally recurrent colorectal cancer after previous endoscopic mucosal resection, making it possible to resect whole lesions and provide precise histologic information.
Real-time endoscopic guidance using near-infrared fluorescent light for thoracic surgery
Venugopal, Vivek; Stockdale, Alan; Neacsu, Florin; Kettenring, Frank; Frangioni, John V.; Gangadharan, Sidharta P.; Gioux, Sylvain
2013-03-01
Lung cancer is the leading cause of cancer death in the United States, accounting for 28% of all cancer deaths. Standard of care for potentially curable lung cancer involves preoperative radiographic or invasive staging, followed by surgical resection. With recent adjuvant chemotherapy and radiation studies showing a survival advantage in nodepositive patients, it is crucial to accurately stage these patients surgically in order to identify those who may benefit. However, lymphadenectomy in lung cancer is currently performed without guidance, mainly due to the lack of tools permitting real-time, intraoperative identification of lymph nodes. In this study we report the design and validation of a novel, clinically compatible near-infrared (NIR) fluorescence thoracoscope for real-time intraoperative guidance during lymphadenectomy. A novel, NIR-compatible, clinical rigid endoscope has been designed and fabricated, and coupled to a custom source and a dual channel camera to provide simultaneous color and NIR fluorescence information to the surgeon. The device has been successfully used in conjunction with a safe, FDA-approved fluorescent tracer to detect and resect mediastinal lymph nodes during thoracic surgery on Yorkshire pigs. Taken together, this study lays the foundation for the clinical translation of endoscopic NIR fluorescence intraoperative guidance and has the potential to profoundly impact the management of lung cancer patients.
International Nuclear Information System (INIS)
Perrot, Yann; Kammerer, Nolwenn; Measson, Yvan; Verney, Alexandre; Gargiulo, Laurent; Houry, Michael; Keller, Delphine; Piolain, Gerard
2012-01-01
The Interactive Robotics Laboratory of CEA LIST is in charge of the development of remote handling technologies to meet energy industry requirements. This paper reports the research and development activities in advanced robotics systems for inspection or light intervention in hazardous environments with limited access such as blind hot cells in the nuclear industry or the thermonuclear experimental Tokamak fusion reactor. A long-reach carrier robot called the articulated inspection arm (AIA) and diagnostics and tools for inspection or intervention are described. Finally experimental field tests are presented and actual challenges in modeling the robot's flexibilities are discussed. (authors)
Vignesh, Shivakumar; Hoffe, Sarah E; Meredith, Kenneth L; Shridhar, Ravi; Almhanna, Khaldoun; Gupta, Akshay K
2013-04-01
Barrett's esophagus (BE) is the most important identifiable risk factor for the progression to esophageal adenocarcinoma. This article reviews the current endoscopic therapies for BE with high-grade dysplasia and intramucosal cancer and briefly discusses the endoscopic palliation of advanced esophageal cancer. The diagnosis of low-grade or high-grade dysplasia (HGD) is based on several cytologic criteria that suggest neoplastic transformation of the columnar epithelium. HGD and carcinoma in situ are regarded as equivalent. The presence of dysplasia, particularly HGD, is also a risk factor for synchronous and metachronous adenocarcinoma. Dysplasia is a marker of adenocarcinoma and also has been shown to be the preinvasive lesion. Esophagectomy has been the conventional treatment for T1 esophageal cancer and, although debated, is an appropriate option in some patients with HGD due to the presence of occult cancer in over one-third of patients. Endoscopic ablative modalities (eg, photodynamic therapy and cryoablation) and endoscopic resection techniques (eg, endoscopic mucosal resection) have demonstrated promising results. The significant morbidity and mortality of esophagectomy makes endoscopic treatment an attractive potential option.
Maeda, Yusaku; Maeda, Kohei; Kobara, Hideki; Mori, Hirohito; Takao, Hidekuni
2017-04-01
In this study, an integrated pressure and temperature sensor device for a flexible endoscope with long-term stability in in vivo environments was developed and demonstrated. The sensor, which is embedded in the thin wall of the disposable endoscope hood, is intended for use in endoscopic surgery. The device surface is coated with a Cr layer to prevent photoelectronic generation induced by the strong light of the endoscope. The integrated temperature sensor allows compensation for the effect of the temperature drift on a pressure signal. The fabricated device pressure resolution is 0.4 mmHg; the corresponding pressure error is 3.2 mmHg. The packaged device was used in a surgical simulation in an animal experiment. Pressure and temperature monitoring was achieved even in a pH 1 acid solution. The device enables intraluminal pressure and temperature measurements of the stomach, which facilitate the maintenance of internal stomach conditions. The applicability of the sensor was successfully demonstrated in animal experiments.
Hwang, Na-Hyun; Lee, Yoon-Hwan; You, Hi-Jin; Yoon, Eul-Sik; Kim, Deok-Woo
2016-07-01
In recent years, endoscope-assisted transoral approach for condylar fracture treatment has attracted much attention. However, the surgical approach is technically challenging: the procedure requires specialized instruments and the surgeons experience a steep learning curve. During the transoral endoscopic (TE) approach several instruments are positioned through a narrow oral incision making endoscope maneuvering very difficult. For this reason, the authors changed the entry port of the endoscope from transoral to submandibular area through a small stab incision. The aim of this study is to assess the advantage of using the submandibular endoscopic intraoral approach (SEI).The SEI approach requires intraoral incision for fracture reduction and fixation, and 4 mm size submandibular stab incision for endoscope and traction wires. Fifteen patients with condyle neck and subcondyle fractures were operated under the submandibular approach and 15 patients with the same diagnosis were operated under the standard TE approach.The SEI approach allowed clear visualization of the posterior margin of the ramus and condyle, and the visual axis was parallel to the condyle ramus unit. The TE approach clearly shows the anterior margin of the condyle and the sigmoid notch. The surgical time of the SEI group was 128 minutes and the TE group was 120 minutes (P >0.05). All patients in the TE endoscope group were fixated with the trocar system, but only 2 lower neck fracture patients in the SEI group required a trocar. The other 13 subcondyle fractures were fixated with an angulated screw driver (P <0.05). There were no differences in complication and surgical outcomes.The submandibular endoscopic approach has an advantage of having more space with good visualization, and facilitated the use of an angulated screw driver.
The NMBU Phenotyping Robot; A Modified Version of Thorvald
Skattum, Kristine
2017-01-01
Soil compaction is a big problem in farming industry. This is why Pål Johan From in 2014, along with four master students, designed and built the agricultural robot Thorvald I. A light weighted robot that avoids soil compaction. Two years later, a new team of master students designed and built Thorvald II, where the goal was to make the robot module based. The modularity formed the basis of this thesis, where the goal was to design a modified version of Thorvald. The modified robot is ord...
R and D on robots for nuclear power plants in 'advanced robot technology' project
International Nuclear Information System (INIS)
Ando, Hiroaki
1987-01-01
The project aims at developing a safe man-robot system of high mobility and workability, highly adaptable to the working environment, and readily and reliably remote-controlled. The plan is to develop 'multi-purpose robots' that can do monitoring, inspection and light work quickly and correctly in areas where access of humans is difficult (e.g. hot spots and the inner space of the primary containment vessel), and 'robots used exclusively for valves, pumps, and other equipment, multi-functional to be used only for specific purposes'. This can be expected to be completed on the basis of results in research and development for the multi-purpose robots. R and D on the total system means manufacturing an optimum system with sufficient functions and performance required for the robot by combining existing technologies most adequately on the basis of the results of research and development on the project. After conceptual drawing and conceptual design, the system will be manufactured and demonstration tests will be completed by fiscal 1987 or 1988. This report describes the total image of the robots concerning the shape, locomotion, manipulation, perception, communication, control management, reliability and environmental durability, and then outlines the research and development activities regarding locomotion, manipulator, tectile sensor, actuator, single-eye three-dimensional measurement, visual data processing, optical spacial transmission, failure repair controller, functional reduction, robot health care and radiation resistance. (Nogami, K.)
Kiekens, Kelli C.; Talarico, Olivia; Barton, Jennifer K.
2018-02-01
A multimodality endoscope system has been designed for early detection of ovarian cancer. Multiple illumination and detection systems must be integrated in a compact, stable, transportable configuration to meet the requirements of a clinical setting. The proximal configuration presented here supports visible light navigation with a large field of view and low resolution, high resolution multiphoton microscopy (MPM), and high resolution optical coherence microscopy (OCM). All modalities are integrated into a single optical system in the endoscope. The system requires two light sources: a green laser for visible light navigation and a compact fiber based femtosecond laser for MPM and OCM. Using an inline wavelength division multiplexer, the two sources are combined into a single mode fiber. To accomplish OCM, a fiber coupler is used to separate the femtosecond laser into a reference arm and signal arm. The reflected reference arm and the signal from the sample are interfered and wavelength separated by a reflection grating and detected using a linear array. The MPM signal is collimated and goes through a series of filters to separate the 2nd and 3rd harmonics as well as twophoton excitation florescence (2PEF) and 3PEF. Each signal is independently detected on a photo multiplier tube and amplified. The visible light is collected by multiple high numerical aperture fibers at the endoscope tip which are bundled into one SMA adapter at the proximal end and connected to a photodetector. This integrated system design is compact, efficient and meets both optical and mechanical requirements for clinical applications.
Visual servo simulation of EAST articulated maintenance arm robot
Energy Technology Data Exchange (ETDEWEB)
Yang, Yang, E-mail: yangyang@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, 350 Shushanhu Rd, Hefei, Anhui (China); Song, Yuntao; Pan, Hongtao; Cheng, Yong; Feng, Hansheng [Institute of Plasma Physics, Chinese Academy of Sciences, 350 Shushanhu Rd, Hefei, Anhui (China); Wu, Huapeng [Lappeenranta University of Technology, Skinnarilankatu 34, Lappeenranta (Finland)
2016-03-15
For the inspection and light-duty maintenance of the vacuum vessel in the EAST tokamak, a serial robot arm, called EAST articulated maintenance arm, is developed. Due to the 9-m-long cantilever arm, the large flexibility of the EAMA robot introduces a problem in the accurate positioning. This article presents an autonomous robot control to cope with the robot positioning problem, which is a visual servo approach in context of tile grasping for the EAMA robot. In the experiments, the proposed method was implemented in a simulation environment to position and track a target graphite tile with the EAMA robot. As a result, the proposed visual control scheme can successfully drive the EAMA robot to approach and track the target tile until the robot reaches the desired position. Furthermore, the functionality of the simulation software presented in this paper is proved to be suitable for the development of the robotic and computer vision application.
Visual servo simulation of EAST articulated maintenance arm robot
International Nuclear Information System (INIS)
Yang, Yang; Song, Yuntao; Pan, Hongtao; Cheng, Yong; Feng, Hansheng; Wu, Huapeng
2016-01-01
For the inspection and light-duty maintenance of the vacuum vessel in the EAST tokamak, a serial robot arm, called EAST articulated maintenance arm, is developed. Due to the 9-m-long cantilever arm, the large flexibility of the EAMA robot introduces a problem in the accurate positioning. This article presents an autonomous robot control to cope with the robot positioning problem, which is a visual servo approach in context of tile grasping for the EAMA robot. In the experiments, the proposed method was implemented in a simulation environment to position and track a target graphite tile with the EAMA robot. As a result, the proposed visual control scheme can successfully drive the EAMA robot to approach and track the target tile until the robot reaches the desired position. Furthermore, the functionality of the simulation software presented in this paper is proved to be suitable for the development of the robotic and computer vision application.
Espinosa-Martos, I; Montilla, A; de Segura, A Gómez; Escuder, D; Bustos, G; Pallás, C; Rodríguez, J M; Corzo, N; Fernández, L
2013-05-01
The objective of this work was to evaluate the effect of Holder pasteurisation of human colostrum on a variety of microbiological, biochemical, and immunological parameters. Colostrum samples from 10 donors, and 8 samples of mature milk used as controls, were heated at 62.5°C for 30 minutes. Bacterial counts and the concentration of furosine, lactose, myoinositol, glucose, lactulose, cytokines, and immunoglobulins were determined before and after the heat treatment. Mean bacterial counts in nonpasteurised colostrum samples oscillated between 2.72 and 4.13 log10 colony-forming units per millilitre in the agar media tested. Holder pasteurisation led to the destruction of the bacteria originally present in the samples. Furosine was detected in all samples before pasteurisation and increased significantly after the heat treatment (from 6.60 to 20.59 mg/100 g protein). Lactulose content was below the detection limit in nonpasteurised colostrum, but it was detected in all samples and quantified in 7 of them (from 10.68 to 38.02 mg/L) after Holder pasteurisation. Lactose, glucose, and myoinositol concentrations did not change after Holder pasteurisation. The concentrations of most cytokines and immunoglobulins were significantly higher in colostrum than in mature milk samples. Immunoglobulin content, both in colostrum and in milk samples, was reduced during pasteurisation, whereas, among cytokines, only macrophage inflammatory protein-1β, interleukin-7, and granulocyte-macrophage-colony-stimulating factor concentrations were affected by this heat treatment. Lactulose and furosine content could be used as heat treatment indicators in colostrum samples. Holder pasteurisation modified the immunological profile of both colostrum and mature milk.
The use of robotics in otolaryngology-head and neck surgery: a systematic review.
Maan, Zeshaan N; Gibbins, Nick; Al-Jabri, Talal; D'Souza, Alwyn R
2012-01-01
Robotic surgery has become increasingly used due to its enhancement of visualization, precision, and articulation. It eliminates many of the problems encountered with conventional minimally invasive techniques and has been shown to result in reduced blood loss and complications. The rise in endoscopic procedures in otolaryngology-head and neck surgery, and associated difficulties, suggests that robotic surgery may have a role to play. To determine whether robotic surgery conveys any benefits compared to conventional minimally invasive approaches, specifically looking at precision, operative time, and visualization. A systematic review of the literature with a defined search strategy. Searches of MEDLINE, EMBASE and CENTRAL using strategy: ((robot* OR (robot*AND surgery)) AND (ent OR otolaryngology)) to November 2010. Articles reviewed by authors and data compiled in tables for analysis. There were 33 references included in the study. Access and visualization were regularly mentioned as key benefits, though no objective data has been recorded in any study. Once initial setup difficulties were overcome, operative time was shown to decrease with robotic surgery, except in one controlled series of thyroid surgeries. Precision was also highlighted as an advantage, particularly in otological and skull base surgery. Postoperative outcomes were considered equivalent to or better than conventional surgery. Cost was the biggest drawback. The evidence base to date suggests there are benefits to robotic surgery in OHNS, particularly with regards to access, precision, and operative time but there is a lack of controlled, prospective studies with objective outcome measures. In addition, economic feasibility studies must be carried out before a robotic OHNS service is established. Copyright © 2012 Elsevier Inc. All rights reserved.
Recent trends for practical rehabilitation robotics, current challenges and the future.
Yakub, Fitri; Md Khudzari, Ahmad Zahran; Mori, Yasuchika
2014-03-01
This paper presents and studies various selected literature primarily from conference proceedings, journals and clinical tests of the robotic, mechatronics, neurology and biomedical engineering of rehabilitation robotic systems. The present paper focuses of three main categories: types of rehabilitation robots, key technologies with current issues and future challenges. Literature on fundamental research with some examples from commercialized robots and new robot development projects related to rehabilitation are introduced. Most of the commercialized robots presented in this paper are well known especially to robotics engineers and scholars in the robotic field, but are less known to humanities scholars. The field of rehabilitation robot research is expanding; in light of this, some of the current issues and future challenges in rehabilitation robot engineering are recalled, examined and clarified with future directions. This paper is concluded with some recommendations with respect to rehabilitation robots.
Endoscopic resection of subepithelial tumors.
Schmidt, Arthur; Bauder, Markus; Riecken, Bettina; Caca, Karel
2014-12-16
Management of subepithelial tumors (SETs) remains challenging. Endoscopic ultrasound (EUS) has improved differential diagnosis of these tumors but a definitive diagnosis on EUS findings alone can be achieved in the minority of cases. Complete endoscopic resection may provide a reasonable approach for tissue acquisition and may also be therapeutic in case of malignant lesions. Small SET restricted to the submucosa can be removed with established basic resection techniques. However, resection of SET arising from deeper layers of the gastrointestinal wall requires advanced endoscopic methods and harbours the risk of perforation. Innovative techniques such as submucosal tunneling and full thickness resection have expanded the frontiers of endoscopic therapy in the past years. This review will give an overview about endoscopic resection techniques of SET with a focus on novel methods.
Load evaluation of the da Vinci surgical system for transoral robotic surgery.
Fujiwara, Kazunori; Fukuhara, Takahiro; Niimi, Koji; Sato, Takahiro; Kitano, Hiroya
2015-12-01
Transoral robotic surgery, performed with the da Vinci surgical system (da Vinci), is a surgical approach for benign and malignant lesions of the oral cavity and laryngopharynx. It provides several unique advantages, which include a 3-dimensional magnified view and ability to see and work around curves or angles. However, the current da Vinci surgical system does not provide haptic feedback. This is problematic because the potential risks specific to the transoral use of the da Vinci include tooth injury, mucosal laceration, ocular injury and mandibular fracture. To assess the potential for intraoperative injuries, we measured the load of the endoscope and the instrument of the da Vinci Si surgical system. We pressed the endoscope and instrument of the da Vinci Si against Load cell six times each and measured the dynamic load and the time-to-maximum load. We also struck the da Vinci Si endoscope and instrument against the Load cell six times each and measured the impact load. The maximum dynamic load was 7.27 ± 1.31 kg for the endoscope and 1.90 ± 0.72 for the instrument. The corresponding time-to-maximum loads were 1.72 ± 0.22 and 1.29 ± 0.34 s, but the impact loads were significantly lower than the dynamic load. It remains possible that a major load is exerted on adjacent structures by continuous contact with the endoscope and instrument of da Vinci Si. However, there is a minor delay in reaching the maximum load. Careful monitoring by an on-site assistant may, therefore, help prevent contiguous injury.
26 CFR 1.860C-1 - Taxation of holders of residual interests.
2010-04-01
... 26 Internal Revenue 9 2010-04-01 2010-04-01 false Taxation of holders of residual interests. 1.860C-1 Section 1.860C-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Real Estate Investment Trusts § 1.860C-1 Taxation of holders...
A mobile autonomous robot for radiological surveys
International Nuclear Information System (INIS)
Dudar, A.M.; Wagner, D.G.; Teese, G.D.
1992-01-01
The Robotics Development Group at the Savannah River Site is developing an autonomous robot (SIMON) to perform radiological surveys of potentially contaminated floors. The robot scans floors at a speed of one-inch/second and stops, sounds an alarm, and flashes lights when contamination in a certain area is detected. The contamination of interest here is primarily alpha and beta-gamma. The robot, a Cybermotion K2A base, is radio controlled, uses dead reckoning to determine vehicle position, and docks with a charging station to replenish its batteries and calibrate its position. It uses an ultrasonic ranging system for collision avoidance. In addition, two safety bumpers located in the front and the back of the robot will stop the robots motion when they are depressed. Paths for the robot are preprogrammed and the robots motion can be monitored on a remote screen which shows a graphical map of the environment. The radiation instrument being used is an Eberline RM22A monitor. This monitor is microcomputer based with a serial I/0 interface for remote operation. Up to 30 detectors may be configured with the RM22A
A sample holder for the study of isothermal heat of hydration of cement
DEFF Research Database (Denmark)
Hansen, Per Freiesleben; Jensen, Ole Mejlhede
1998-01-01
Different techniques for measuring heat of hydration of cement are discussed, and a sample holder designed specially for measuring isothermal heat of hydration is described. A particular characteristic of the sample holder is the vacuum mixing technique which ensures a momentary and homogeneous...
16 CFR Figure 3 to Part 1610 - Specimen Holder Supported in Specimen Rack
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Specimen Holder Supported in Specimen Rack 3 Figure 3 to Part 1610 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT... Holder Supported in Specimen Rack ER25MR08.002 ...
A novel robotic system for single-port urologic surgery: first clinical investigation.
Kaouk, Jihad H; Haber, Georges-Pascal; Autorino, Riccardo; Crouzet, Sebastien; Ouzzane, Adil; Flamand, Vincent; Villers, Arnauld
2014-12-01
The idea of performing a laparoscopic procedure through a single abdominal incision was conceived with the aim of expediting postoperative recovery. To determine the clinical feasibility and safety of single-port urologic procedures by using a novel robotic surgical system. This was a prospective institutional review board-approved, Innovation, Development, Exploration, Assessment, Long-term Study (IDEAL) phase 1 study. After enrollment, patients underwent a major urologic robotic single-port procedure over a 3-wk period in July 2010. The patients were followed for 3 yr postoperatively. Different types of urologic surgeries were performed using the da Vinci SP Surgical System. This system is intended to provide the same core clinical capabilities as the existing multiport da Vinci system, except that three articulating endoscopic instruments and an articulating endoscopic camera are inserted into the patient through a single robotic port. The main outcomes were the technical feasibility of the procedures (as measured by the rate of conversions) and the safety of the procedures (as measured by the incidence of perioperative complications). Secondary end points consisted of evaluating other key surgical perioperative outcomes as well as midterm functional and oncologic outcomes. A total of 19 patients were enrolled in the study. Eleven of them underwent radical prostatectomy; eight subjects underwent nephrectomy procedures (partial nephrectomy, four; radical nephrectomy, two; and simple nephrectomy, two). There were no conversions to alternative surgical approaches. Overall, two major (Clavien grade 3b) postoperative complications were observed in the radical prostatectomy group and none in the nephrectomy group. At 1-yr follow-up, one radical prostatectomy patient experienced biochemical recurrence, which was successfully treated with salvage radiation therapy. The median warm ischemia time for three of the partial nephrectomies was 38 min. At 3-yr follow-up all
Automatic gamma radiation scanning device and feed mechanism for plural sample holders
International Nuclear Information System (INIS)
Byrd, W.J.
1976-01-01
Apparatus is disclosed for measuring the level of gamma radiation contained in a plurality of biological samples which are located on the fibrous sheet member carried by a sample holder. The apparatus is adapted to count the radiation level of the number of closely spaced samples located in rows and columns on the sheet by automatically sequencing through the individual samples within the rows and to advance the holder to bring successive rows into proximity with the detector. The detector is moved from sample to sample within the rows, although a number of detectors can be employed. A plurality of sample holders are automatically advanced to the detector. 25 claims, 5 drawing figures
Submucosal tunnel endoscopy: Peroral endoscopic myotomy and peroral endoscopic tumor resection
Eleftheriadis, Nikolas; Inoue, Haruhiro; Ikeda, Haruo; Onimaru, Manabu; Maselli, Roberta; Santi, Grace
2016-01-01
Peroral endoscopic myotomy (POEM) is an innovative, minimally invasive, endoscopic treatment for esophageal achalasia and other esophageal motility disorders, emerged from the natural orifice transluminal endoscopic surgery procedures, and since the first human case performed by Inoue in 2008, showed exciting results in international level, with more than 4000 cases globally up to now. POEM showed superior characteristics than the standard 100-year-old surgical or laparoscopic Heller myotomy (LHM), not only for all types of esophageal achalasia [classical (I), vigorous (II), spastic (III), Chicago Classification], but also for advanced sigmoid type achalasia (S1 and S2), failed LHM, or other esophageal motility disorders (diffuse esophageal spasm, nutcracker esophagus or Jackhammer esophagus). POEM starts with a mucosal incision, followed by submucosal tunnel creation crossing the esophagogastric junction (EGJ) and myotomy. Finally the mucosal entry is closed with endoscopic clip placement. POEM permitted relatively free choice of myotomy length and localization. Although it is technically demanding procedure, POEM can be performed safely and achieves very good control of dysphagia and chest pain. Gastroesophageal reflux is the most common troublesome side effect, and is well controllable with proton pump inhibitors. Furthermore, POEM opened the era of submucosal tunnel endoscopy, with many other applications. Based on the same principles with POEM, in combination with new technological developments, such as endoscopic suturing, peroral endoscopic tumor resection (POET), is safely and effectively applied for challenging submucosal esophageal, EGJ and gastric cardia tumors (submucosal tumors), emerged from muscularis propria. POET showed up to know promising results, however, it is restricted to specialized centers. The present article reviews the recent data of POEM and POET and discussed controversial issues that need further study and future perspectives. PMID
19 CFR 134.22 - General rules for marking of containers or holders.
2010-04-01
... required for any good of a NAFTA country which is a usual container. (c) Containers or holders bearing a U.S. address. Containers or holders of imported merchandise bearing the name and address of an... shaped or fitted to contain a specific good or set of goods such as a camera case or an eyeglass case, or...
CFD analysis of a scramjet combustor with cavity based flame holders
Kummitha, Obula Reddy; Pandey, Krishna Murari; Gupta, Rajat
2018-03-01
Numerical analysis of a scramjet combustor with different cavity flame holders has been carried out using ANSYS 16 - FLUENT tool. In this research article the internal fluid flow behaviour of the scramjet combustor with different cavity based flame holders have been discussed in detail. Two dimensional Reynolds-Averaged Navier-Stokes governing(RANS) equations and shear stress turbulence (SST) k - ω model along with finite rate/eddy dissipation chemistry turbulence have been considered for modelling chemical reacting flows. Due to the advantage of less computational time, global one step reaction mechanism has been used for combustion modelling of hydrogen and air. The performance of the scramjet combustor with two different cavities namely spherical and step cavity has been compared with the standard DLR scramjet. From the comparison of numerical results, it is found that the development of recirculation regions and additional shock waves from the edge of cavity flame holder is increased. And also it is observed that with the cavity flame holder the residence time of air in the scramjet combustor is also increased and achieved stabilized combustion. From this research analysis, it has been found that the mixing and combustion efficiency of scramjet combustor with step cavity design is optimum as compared to other models.
Endoscopic approaches to treatment of achalasia
Friedel, David; Modayil, Rani; Iqbal, Shahzad; Grendell, James H.
2013-01-01
Endoscopic therapy for achalasia is directed at disrupting or weakening the lower esophageal sphincter (LES). The two most commonly utilized endoscopic interventions are large balloon pneumatic dilation (PD) and botulinum toxin injection (BTI). These interventions have been extensively scrutinized and compared with each other as well as with surgical disruption (myotomy) of the LES. PD is generally more effective in improving dysphagia in achalasia than BTI, with the latter reserved for infirm older people, and PD may approach treatment results attained with myotomy. However, PD may need to be repeated. Small balloon dilation and endoscopic stent placement for achalasia have only been used in select centers. Per oral endoscopic myotomy is a newer endoscopic modality that will likely change the treatment paradigm for achalasia. It arose from the field of natural orifice transluminal endoscopic surgery and represents a scarless endoscopic approach to Heller myotomy. This is a technique that requires extensive training and preparation and thus there should be rigorous accreditation and monitoring of outcomes to ensure safety and efficacy. PMID:23503707
Visual dataflow language for educational robots programming
ZIMIN G.A.; MORDVINOV D.A.
2016-01-01
Visual domain-specific languages usually have low entry barrier. Sometimes even children can program on such languages by working with visual representations. This is widely used in educational robotics domain, where most commonly used programming environments are visual. The paper describes a novel dataflow visual programming environment for embedded robotic platforms. Obviously, complex dataflow languages are not simple for understanding. The purpose of our tool is to "bridge" between light...
Development of Industrial High-Speed Transfer Parallel Robot
International Nuclear Information System (INIS)
Kim, Byung In; Kyung, Jin Ho; Do, Hyun Min; Jo, Sang Hyun
2013-01-01
Parallel robots used in industry require high stiffness or high speed because of their structural characteristics. Nowadays, the importance of rapid transportation has increased in the distribution industry. In this light, an industrial parallel robot has been developed for high-speed transfer. The developed parallel robot can handle a maximum payload of 3 kg. For a payload of 0.1 kg, the trajectory cycle time is 0.3 s (come and go), and the maximum velocity is 4.5 m/s (pick amp, place work, adept cycle). In this motion, its maximum acceleration is very high and reaches approximately 13g. In this paper, the design, analysis, and performance test results of the developed parallel robot system are introduced
Controlling Tensegrity Robots Through Evolution
Iscen, Atil; Agogino, Adrian; SunSpiral, Vytas; Tumer, Kagan
2013-01-01
Tensegrity structures (built from interconnected rods and cables) have the potential to offer a revolutionary new robotic design that is light-weight, energy-efficient, robust to failures, capable of unique modes of locomotion, impact tolerant, and compliant (reducing damage between the robot and its environment). Unfortunately robots built from tensegrity structures are difficult to control with traditional methods due to their oscillatory nature, nonlinear coupling between components and overall complexity. Fortunately this formidable control challenge can be overcome through the use of evolutionary algorithms. In this paper we show that evolutionary algorithms can be used to efficiently control a ball-shaped tensegrity robot. Experimental results performed with a variety of evolutionary algorithms in a detailed soft-body physics simulator show that a centralized evolutionary algorithm performs 400 percent better than a hand-coded solution, while the multi-agent evolution performs 800 percent better. In addition, evolution is able to discover diverse control solutions (both crawling and rolling) that are robust against structural failures and can be adapted to a wide range of energy and actuation constraints. These successful controls will form the basis for building high-performance tensegrity robots in the near future.
Ebola Virus and Marburg Virus in Human Milk Are Inactivated by Holder Pasteurization.
Hamilton Spence, Erin; Huff, Monica; Shattuck, Karen; Vickers, Amy; Yun, Nadezda; Paessler, Slobodan
2017-05-01
Potential donors of human milk are screened for Ebola virus (EBOV) using standard questions, but testing for EBOV and Marburg virus (MARV) is not part of routine serological testing performed by milk banks. Research aim: This study tested the hypothesis that EBOV would be inactivated in donor human milk (DHM) by standard pasteurization techniques (Holder) used in all North American nonprofit milk banks. Milk samples were obtained from a nonprofit milk bank. They were inoculated with EBOV (Zaire strain) and MARV (Angola strain) and processed by standard Holder pasteurization technique. Plaque assays for EBOV and MARV were performed to detect the presence of virus after pasteurization. Neither EBOV nor MARV was detectable by viral plaque assay in DHM or culture media samples, which were pasteurized by the Holder process. EBOV and MARV are safely inactivated in human milk by standard Holder pasteurization technique. Screening for EBOV or MARV beyond questionnaire and self-deferral is not needed to ensure safety of DHM for high-risk infants.
[Endoscopic extraction of gallbladder calculi].
Kühner, W; Frimberger, E; Ottenjann, R
1984-06-29
Endoscopic extraction of gallbladder stones were performed, as far as we know for the first time, in three patients with combined choledochocystolithiasis. Following endoscopic papillotomy (EPT) and subsequent mechanical lithotripsy of multiple choledochal concrements measuring up to 3 cm the gallbladder stones were successfully extracted with a Dormia basket through the cystic duct. The patients have remained free of complications after the endoscopic intervention.
The human hand as an inspiration for robot hand development
Santos, Veronica
2014-01-01
“The Human Hand as an Inspiration for Robot Hand Development” presents an edited collection of authoritative contributions in the area of robot hands. The results described in the volume are expected to lead to more robust, dependable, and inexpensive distributed systems such as those endowed with complex and advanced sensing, actuation, computation, and communication capabilities. The twenty-four chapters discuss the field of robotic grasping and manipulation viewed in light of the human hand’s capabilities and push the state-of-the-art in robot hand design and control. Topics discussed include human hand biomechanics, neural control, sensory feedback and perception, and robotic grasp and manipulation. This book will be useful for researchers from diverse areas such as robotics, biomechanics, neuroscience, and anthropologists.
Directory of Open Access Journals (Sweden)
Apollon Zygomalas
2014-01-01
Full Text Available Aim. Modular mini-robots can be used in novel minimally invasive surgery techniques like natural orifice transluminal endoscopic surgery (NOTES and laparoendoscopic single site (LESS surgery. The control of these miniature assistants is complicated. The aim of this study is the in silico investigation of a remote controlling interface for modular miniature robots which can be used in minimally invasive surgery. Methods. The conceptual controlling system was developed, programmed, and simulated using professional robotics simulation software. Three different modes of control were programmed. The remote controlling surgical interface was virtually designed as a high scale representation of the respective modular mini-robot, therefore a modular controlling system itself. Results. With the proposed modular controlling system the user could easily identify the conformation of the modular mini-robot and adequately modify it as needed. The arrangement of each module was always known. The in silico investigation gave useful information regarding the controlling mode, the adequate speed of rearrangements, and the number of modules needed for efficient working tasks. Conclusions. The proposed conceptual model may promote the research and development of more sophisticated modular controlling systems. Modular surgical interfaces may improve the handling and the dexterity of modular miniature robots during minimally invasive procedures.
A Fast Vision System for Soccer Robot
Directory of Open Access Journals (Sweden)
Tianwu Yang
2012-01-01
Full Text Available This paper proposes a fast colour-based object recognition and localization for soccer robots. The traditional HSL colour model is modified for better colour segmentation and edge detection in a colour coded environment. The object recognition is based on only the edge pixels to speed up the computation. The edge pixels are detected by intelligently scanning a small part of whole image pixels which is distributed over the image. A fast method for line and circle centre detection is also discussed. For object localization, 26 key points are defined on the soccer field. While two or more key points can be seen from the robot camera view, the three rotation angles are adjusted to achieve a precise localization of robots and other objects. If no key point is detected, the robot position is estimated according to the history of robot movement and the feedback from the motors and sensors. The experiments on NAO and RoboErectus teen-size humanoid robots show that the proposed vision system is robust and accurate under different lighting conditions and can effectively and precisely locate robots and other objects.
Phosphor converted laser diode light source for endoscopic diagnostics
DEFF Research Database (Denmark)
Krasnoshchoka, Anastasiia; Thorseth, Anders; Dam-Hansen, Carsten
2017-01-01
of the generated white light into thin optical fibres. The development involves designing optics for optimizing the light extraction efficiency and guiding of light to the area of interest. In this paper we compared the developed light source to the current standard in endoscopy – xenon arc lamps. Detailed...
Endoscopic findings following retroperitoneal pancreas transplantation.
Pinchuk, Alexey V; Dmitriev, Ilya V; Shmarina, Nonna V; Teterin, Yury S; Balkarov, Aslan G; Storozhev, Roman V; Anisimov, Yuri A; Gasanov, Ali M
2017-07-01
An evaluation of the efficacy of endoscopic methods for the diagnosis and correction of surgical and immunological complications after retroperitoneal pancreas transplantation. From October 2011 to March 2015, 27 patients underwent simultaneous retroperitoneal pancreas-kidney transplantation (SPKT). Diagnostic oesophagogastroduodenoscopy (EGD) with protocol biopsy of the donor and recipient duodenal mucosa and endoscopic retrograde pancreatography (ERP) were performed to detect possible complications. Endoscopic stenting of the main pancreatic duct with plastic stents and three-stage endoscopic hemostasis were conducted to correct the identified complications. Endoscopic methods showed high efficiency in the timely diagnosis and adequate correction of complications after retroperitoneal pancreas transplantation. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
F.J.C. van den Broek (Frank); E.J.R. de Graaf (Eelco); M.G.W. Dijkgraaf (Marcel); J.B. Reitsma (Johannes); J. Haringsma (Jelle); R. Timmer (Robin); B.L. Weusten (Bas); M.F. Gerhards (Michael); E.C. Consten (Esther); M.P. Schwartz (Matthijs); M.J. Boom (Maarten); E.J. Derksen (Erik); A.B. Bijnen (Bart); P.H.P. Davids (Paul); C. Hoff (Christiaan); H.M. van Dullemen (Hendrik); G.D.N. Heine (Dimitri); K. van der Linde (Klaas); J.M. Jansen (Jeroen); R.C.H. Mallant-Hent (Rosalie); R. Breumelhof (Ronald); H. Geldof (Han); J.C. Hardwick (James); P. Doornebosch (Pascal); A.C.T.M. Depla (Annekatrien); M.F. Ernst (Miranda); I.P. van Munster (Ivo); I.H.J.T. de Hingh (Ignace); E.J. Schoon (Erik); W.A. Bemelman (Willem); P. Fockens (Paul); E. Dekker (Evelien)
2009-01-01
textabstractBackground: Recent non-randomized studies suggest that extended endoscopic mucosal resection (EMR) is equally effective in removing large rectal adenomas as transanal endoscopic microsurgery (TEM). If equally effective, EMR might be a more cost-effective approach as this strategy does
Robots that can adapt like animals.
Cully, Antoine; Clune, Jeff; Tarapore, Danesh; Mouret, Jean-Baptiste
2015-05-28
Robots have transformed many industries, most notably manufacturing, and have the power to deliver tremendous benefits to society, such as in search and rescue, disaster response, health care and transportation. They are also invaluable tools for scientific exploration in environments inaccessible to humans, from distant planets to deep oceans. A major obstacle to their widespread adoption in more complex environments outside factories is their fragility. Whereas animals can quickly adapt to injuries, current robots cannot 'think outside the box' to find a compensatory behaviour when they are damaged: they are limited to their pre-specified self-sensing abilities, can diagnose only anticipated failure modes, and require a pre-programmed contingency plan for every type of potential damage, an impracticality for complex robots. A promising approach to reducing robot fragility involves having robots learn appropriate behaviours in response to damage, but current techniques are slow even with small, constrained search spaces. Here we introduce an intelligent trial-and-error algorithm that allows robots to adapt to damage in less than two minutes in large search spaces without requiring self-diagnosis or pre-specified contingency plans. Before the robot is deployed, it uses a novel technique to create a detailed map of the space of high-performing behaviours. This map represents the robot's prior knowledge about what behaviours it can perform and their value. When the robot is damaged, it uses this prior knowledge to guide a trial-and-error learning algorithm that conducts intelligent experiments to rapidly discover a behaviour that compensates for the damage. Experiments reveal successful adaptations for a legged robot injured in five different ways, including damaged, broken, and missing legs, and for a robotic arm with joints broken in 14 different ways. This new algorithm will enable more robust, effective, autonomous robots, and may shed light on the principles
Punishability of office-holders in environmental law
International Nuclear Information System (INIS)
Papier, H.J.
1988-01-01
The author deals with the question of criminal responsibility of office-holders in the field of environmental law. The provisions in secs. 324-330 of the Penal Code do not grant independent or origin protection from violation of the law. They depend on administrative law regulations. (WG) [de
Intelligent robots for nuclear power plant inspection and surveillance
International Nuclear Information System (INIS)
Miyazawa, Tatsuo; Suzuki, Kazumi; Fujie, Hideo; Fujii, Masaaki; Asai, Takashi; Sugimoto, Hiroshi.
1986-01-01
Recently, the research and development of robotizing the patrol and works in nuclear power plants have been actively carried out since the TMI-2 accident in March, 1979. In this paper, among these robots, six examples of the movable robots, of which the working and movement were intellectualized by using information processing techniques and others, are reported, and their intellectualization is concretely discussed. In Japan, the development of the supporting system for nuclear power generation was carried out for five years from fiscal year 1980 as the project subsidized by the Ministry of International Trade and Industry, and during this period, the inspection robots for LWR plants were developed. The development of the robots for ultimate working as the large scale project of the Agency of Industrial Science and Technology aiming at further heightening the function is in progress as the eight-year project from fiscal year 1983. Monorail type automatic surveillance robots, system maintenance robots 'AMOOTY', variable crawler type intelligent movable robots, hybrid running type intelligent movable robots, monorail running type small checkup robots, and floor running type checkup and light work robots are reported. Sense information processing control and a robot language processor for expanding the function of autonomous control are outlined. (Kako, I.)
Scholl, Annika; Sassenberg, Kai; Ellemers, Naomi; Scheepers, Daan; de Wit, Frank
2018-01-01
Power relations affect dynamics within groups. Power-holders' decisions not only determine their personal outcomes, but also the outcomes of others in the group that they control. Yet, power-holders often tend to overlook this responsibility to take care of collective interests. The present research investigated how social identification - with the group to which both the powerful and the powerless belong - alters perceived responsibility among power-holders (and the powerless). Combining research on social power and social identity, we argue that power-holders perceive more responsibility than the powerless when strongly (rather than when weakly) identifying with the group. A study among leaders and an experiment supported this, highlighting that although power-holders are often primarily concerned about personal outcomes, they do feel responsible for considering others' interests when these others are included in the (social) self. © 2017 The British Psychological Society.
Barret, E; Sanchez-Salas, R; Ercolani, M; Forgues, A; Rozet, F; Galiano, M; Cathelineau, X
2011-06-01
The objective of this manuscript is to provide an evidence-based analysis of the current status and future perspectives of robotic laparoendoscopic single-site surgery (R-LESS). A PubMed search has been performed for all relevant urological literature regarding natural orifice transluminal endoscopic surgery (NOTES) and laparoendoscopic single-site surgery (LESS). All clinical and investigative reports for robotic LESS and NOTES procedures in the urological literature have been considered. A significant number of clinical urological procedures have been successfully completed utilizing R-LESS procedures. The available experience is limited to referral centers, where the case volume is sufficient to help overcome the challenges and learning curve of LESS surgery. The robotic interface remains the best fit for LESS procedures but its mode of use continues to evolve in attempts to improve surgical technique. We stand today at the dawn of R-LESS surgery, but this approach may well become the standard of care in the near future. Further technological development is needed to allow widespread adoption of the technique.
van den Broek, Frank J. C.; de Graaf, Eelco J. R.; Dijkgraaf, Marcel G. W.; Haringsma, Jelle; Timmer, Robin; Weusten, Bas L. A. M.; Gerhards, Michael F.; Consten, Esther C. J.; Schwartz, Matthijs P.; Boom, Maarten J.; Derksen, Erik J.; Bijnen, A. Bart; Davids, Paul H. P.; Hoff, Christiaan; van Dullemen, Hendrik M.; Heine, G. Dimitri N.; van der Linde, Klaas; Jansen, Jeroen M.; Mallant-Hent, Rosalie C. H.; Breumelhof, Ronald; Geldof, Han; Hardwick, James C. H.; Doornebosch, Pascal G.; Depla, Annekatrien C. T. M.; Ernst, Miranda F.; van Munster, Ivo P.; de Hingh, Ignace H. J. T.; Schoon, Erik J.; Bemelman, Willem A.; Fockens, Paul; Dekker, Evelien; Reitsma, J.
2009-01-01
Background: Recent non-randomized studies suggest that extended endoscopic mucosal resection (EMR) is equally effective in removing large rectal adenomas as transanal endoscopic microsurgery (TEM). If equally effective, EMR might be a more cost-effective approach as this strategy does not require
[Endoscopic full-thickness resection].
Meier, B; Schmidt, A; Caca, K
2016-08-01
Conventional endoscopic resection techniques such as endoscopic mucosal resection (EMR) or endoscopic submucosal dissection (ESD) are powerful tools for the treatment of gastrointestinal (GI) neoplasms. However, those techniques are limited to the superficial layers of the GI wall (mucosa and submucosa). Lesions without lifting sign (usually arising from deeper layers) or lesions in difficult anatomic positions (appendix, diverticulum) are difficult - if not impossible - to resect using conventional techniques, due to the increased risk of complications. For larger lesions (>2 cm), ESD appears to be superior to the conventional techniques because of the en bloc resection, but the procedure is technically challenging, time consuming, and associated with complications even in experienced hands. Since the development of the over-the-scope clips (OTSC), complications like bleeding or perforation can be endoscopically better managed. In recent years, different endoscopic full-thickness resection techniques came to the focus of interventional endoscopy. Since September 2014, the full-thickness resection device (FTRD) has the CE marking in Europe for full-thickness resection in the lower GI tract. Technically the device is based on the OTSC system and combines OTSC application and snare polypectomy in one step. This study shows all full-thickness resection techniques currently available, but clearly focuses on the experience with the FTRD in the lower GI tract.
Darfur and the flaws of Holder v HLP
Directory of Open Access Journals (Sweden)
Christopher Thornton
2011-03-01
Full Text Available When US Chief Justice Roberts handed down the judgment in Holder v Humanitarian Law Project, he revealed the Supreme Court’s tragic under-estimation of the potential of engagement with non-state armed groups....
Laws on Robots, Laws by Robots, Laws in Robots : Regulating Robot Behaviour by Design
Leenes, R.E.; Lucivero, F.
2015-01-01
Speculation about robot morality is almost as old as the concept of a robot itself. Asimov’s three laws of robotics provide an early and well-discussed example of moral rules robots should observe. Despite the widespread influence of the three laws of robotics and their role in shaping visions of
[Implementation of a robotic video-assisted thoracic surgical program].
Baste, J-M; Riviera, C; Nouhaud, F-X; Rinieri, P; Melki, J; Peillon, C
2016-03-01
Recent publications from North America have shown the benefits of robot-assisted thoracic surgery. We report here the process of setting up such a program in a French university centre and early results in a unit with an average treatment volume. Retrospective review of a single institution database. The program was launched after a 6-month preparation period. From January 2012 to January 2013, totally endoscopic, full robot-assisted procedures were performed on 30 patients (17 males). Median age was 54 [Q1-Q3, 48-63] years and ASA score 2 [1,2]. Operative procedures included thymectomy (9 ; 30%), lobectomy with nodes resection (11 ; 38%), segmentectomy (4 ; 14%), lymphadenectomy (3 ; 10%), Bronchogenic cyst (2, 5%) and posterior mediastinal mass resection (1 ; 3%). No conversion was required. Median blood loss was 50mL [10-100]. Median operating time was 135 min (105-165) including 30 min [20-40] for docking, 90min for robot-assisted operating [70-120] and 15 min [10-15] for lesion extraction. CO2 insufflation was used in 28 cases (93%). Hospital stay was 4 days [4-6] with 6 minor complications (20%) (Grade 1 according to the Clavien-Dindo classification). After a median 4 months follow-up [2-7], all patients were alive and demonstrated a good quality of life. This series suggests that full robotic thoracic procedures are safe and effective treatment for various pathologies, with low morbidity and without a significant learning curve, even in a lower volume centre. This technology should accompany the development of minimally invasive thoracic surgery. The importance of robotic training should be emphasized to optimize procedures and costs. Copyright © 2015 SPLF. Published by Elsevier Masson SAS. All rights reserved.
Endoscopic full-thickness resection: Current status.
Schmidt, Arthur; Meier, Benjamin; Caca, Karel
2015-08-21
Conventional endoscopic resection techniques such as endoscopic mucosal resection or endoscopic submucosal dissection are powerful tools for treatment of gastrointestinal neoplasms. However, those techniques are restricted to superficial layers of the gastrointestinal wall. Endoscopic full-thickness resection (EFTR) is an evolving technique, which is just about to enter clinical routine. It is not only a powerful tool for diagnostic tissue acquisition but also has the potential to spare surgical therapy in selected patients. This review will give an overview about current EFTR techniques and devices.
Macrobend optical sensing for pose measurement in soft robot arms
International Nuclear Information System (INIS)
Sareh, Sina; Noh, Yohan; Liu, Hongbin; Althoefer, Kaspar; Li, Min; Ranzani, Tommaso
2015-01-01
This paper introduces a pose-sensing system for soft robot arms integrating a set of macrobend stretch sensors. The macrobend sensory design in this study consists of optical fibres and is based on the notion that bending an optical fibre modulates the intensity of the light transmitted through the fibre. This sensing method is capable of measuring bending, elongation and compression in soft continuum robots and is also applicable to wearable sensing technologies, e.g. pose sensing in the wrist joint of a human hand. In our arrangement, applied to a cylindrical soft robot arm, the optical fibres for macrobend sensing originate from the base, extend to the tip of the arm, and then loop back to the base. The connectors that link the fibres to the necessary opto-electronics are all placed at the base of the arm, resulting in a simplified overall design. The ability of this custom macrobend stretch sensor to flexibly adapt its configuration allows preserving the inherent softness and compliance of the robot which it is installed on. The macrobend sensing system is immune to electrical noise and magnetic fields, is safe (because no electricity is needed at the sensing site), and is suitable for modular implementation in multi-link soft continuum robotic arms. The measurable light outputs of the proposed stretch sensor vary due to bend-induced light attenuation (macrobend loss), which is a function of the fibre bend radius as well as the number of repeated turns. The experimental study conducted as part of this research revealed that the chosen bend radius has a far greater impact on the measured light intensity values than the number of turns (if greater than five). Taking into account that the bend radius is the only significantly influencing design parameter, the macrobend stretch sensors were developed to create a practical solution to the pose sensing in soft continuum robot arms. Henceforward, the proposed sensing design was benchmarked against an electromagnetic
Novel methods for endoscopic training.
Gessner, C E; Jowell, P S; Baillie, J
1995-04-01
The development of past, present, and future endoscopic training methods is described. A historical perspective of endoscopy training guidelines and devices is used to demonstrate support for the use of novel endoscopic training techniques. Computer simulation of endoscopy, interactive learning, and virtual reality applications in endoscopy and surgery are reviewed. The goals of endoscopic simulation and challenges facing investigators in this field are discussed, with an emphasis on current and future research.
Origami-based earthworm-like locomotion robots.
Fang, Hongbin; Zhang, Yetong; Wang, K W
2017-10-16
Inspired by the morphology characteristics of the earthworms and the excellent deformability of origami structures, this research creates a novel earthworm-like locomotion robot through exploiting the origami techniques. In this innovation, appropriate actuation mechanisms are incorporated with origami ball structures into the earthworm-like robot 'body', and the earthworm's locomotion mechanism is mimicked to develop a gait generator as the robot 'centralized controller'. The origami ball, which is a periodic repetition of waterbomb units, could output significant bidirectional (axial and radial) deformations in an antagonistic way similar to the earthworm's body segment. Such bidirectional deformability can be strategically programmed by designing the number of constituent units. Experiments also indicate that the origami ball possesses two outstanding mechanical properties that are beneficial to robot development: one is the structural multistability in the axil direction that could contribute to the robot control implementation; and the other is the structural compliance in the radial direction that would increase the robot robustness and applicability. To validate the origami-based innovation, this research designs and constructs three robot segments based on different axial actuators: DC-motor, shape-memory-alloy springs, and pneumatic balloon. Performance evaluations reveal their merits and limitations, and to prove the concept, the DC-motor actuation is selected for building a six-segment robot prototype. Learning from earthworms' fundamental locomotion mechanism-retrograde peristalsis wave, seven gaits are automatically generated; controlled by which, the robot could achieve effective locomotion with qualitatively different modes and a wide range of average speeds. The outcomes of this research could lead to the development of origami locomotion robots with low fabrication costs, high customizability, light weight, good scalability, and excellent re-configurability.
A Fully Sensorized Cooperative Robotic System for Surgical Interventions
Tovar-Arriaga, Saúl; Vargas, José Emilio; Ramos, Juan M.; Aceves, Marco A.; Gorrostieta, Efren; Kalender, Willi A.
2012-01-01
In this research a fully sensorized cooperative robot system for manipulation of needles is presented. The setup consists of a DLR/KUKA Light Weight Robot III especially designed for safe human/robot interaction, a FD-CT robot-driven angiographic C-arm system, and a navigation camera. Also, new control strategies for robot manipulation in the clinical environment are introduced. A method for fast calibration of the involved components and the preliminary accuracy tests of the whole possible errors chain are presented. Calibration of the robot with the navigation system has a residual error of 0.81 mm (rms) with a standard deviation of ±0.41 mm. The accuracy of the robotic system while targeting fixed points at different positions within the workspace is of 1.2 mm (rms) with a standard deviation of ±0.4 mm. After calibration, and due to close loop control, the absolute positioning accuracy was reduced to the navigation camera accuracy which is of 0.35 mm (rms). The implemented control allows the robot to compensate for small patient movements. PMID:23012551
Zerrin AŞAN GREENACRE
2018-01-01
Nowadays, doctorate holders are not only academician and researcher, also they play roles across a wide range of working areas within society. These areas are increasing multiway. The aim of this study is to give statistical evaluation careers of doctorate holders survey using the correspondence analysis with supplementary variables. In this paper we focused on careers of doctorate holders in Turkey. It was held a survey by Turkish Statistical Institute on this s...
Systems and methods for large-scale nanotemplate and nanowire fabrication
Vidal, Enrique Vilanova
2016-03-31
Systems and methods for largescale nanotemplate and nanowire fabrication are provided. The system can include a sample holder and one or more chemical containers fluidly connected to the sample holder. The sample holder can be configured to contain a solution and to releasably hold a substrate material within the solution. In other aspects, the system can include a robotic arm including a head configured to releasably hold a substrate material. The methods can include initiating a treatment step by moving a chemical solution from a chemical container to the sample holder to submerge the substrate material for a period of time. The methods can include moving the robotic arm to position the substrate in a chemical container. The treatment steps can be stopped by removing the chemical solution from the sample holder or by moving the robotic arm to remove the substrate from the chemical container. The treatment steps can include degreasing, polishing, rinsing, anodization, and deposition.
Directory of Open Access Journals (Sweden)
Barlian Henryranu P.
2014-07-01
Full Text Available Abstrak Dengan menggabungkan Sistem Kontrol, sensor dan motor Servo diharapkan Robot segway dapat direalisasikan. Dalam penelitian ini Sistem Kontrol yang digunakan adalah metode PID, sedangkan sensor yang akan digunakan adalah cahaya yang merepresentasikan sudut kemiringan terhadap bumi. Dengan input berupa Error sudut dan Del Error sudut terhadap bumi maka didapatkan hasil PID kontroller berupa angular rate yang digunakan untuk mengontrol kedua rodanya. Robot Segway memiliki rise time/fall time, settling time dan Robot Segway mampu mencapai kesetimbangannya kembali (steady state setelah mendapatkan gangguan dari luar. Kata kunci: Robot kesetimbangan, sensor cahaya, PID kontroler Abstract By combining the Control System, sensors and Servos motors are expected to Segway can be realized. In this research use the PID method, while the sensor to be used is the light that represents the elevation angle of the earth. With the input is angel Error and angel Del Error of the earth then the results obtained in the form of angular rate PID Controller is used to Control the two wheels. Segway Robot has a rise time / fall time, settling time and Segway Robot can reach the balance again (steady state after get a outside disturbance. Keywords: Self-balancing robot, light sensor, PID Controller
Endoscopic medial maxillectomy breaking new frontiers.
Mohanty, Sanjeev; Gopinath, M
2013-07-01
Endoscopy has changed the perspective of rhinologist towards the nose. It has revolutionised the surgical management of sinonasal disorders. Sinus surgeries were the first to get the benefit of endoscope. Gradually the domain of endoscopic surgery extended to the management of sino nasal tumours. Traditionally medial maxillectomy was performed through lateral rhinotomy or mid facial degloving approach. Endoscopic medial maxillectomy has been advocated by a number of authors in the management of benign sino-nasal tumours. We present our experience of endoscopic medial maxillectomy in the management of sinonasal pathologies.
14 CFR Appendix O to Part 121 - Hazardous Materials Training Requirements For Certificate Holders
2010-01-01
... K of this chapter. The training requirements for various categories of persons are defined by job... to persons actually performing the job function. Training requirements for certificate holders.... The method of delivering the training will be determined by the certificate holder. The certificate...
7 CFR 762.144 - Repurchase of guaranteed portion from a secondary market holder.
2010-01-01
... discrepancy is resolved. (iii) In the case of a request for Agency purchase, the Agency will only pay interest... and the amount due the holder. (ii) Any discrepancy between the amount claimed by the holder and the... approved by the Agency. The Agency will not participate in resolution of any such discrepancy. When there...
Endoscopic management of bleeding peptic ulcers
International Nuclear Information System (INIS)
Farooqi, J.I.; Farooqi, R.J.
2001-01-01
Peptic ulcers account for more than half of the cases of non variceal upper gastrointestinal (GI) bleeding and therefore, are the focus of most of the methods of endoscopic hemostasis. Surgical intervention is now largely reserved for patients in whom endoscopic hemostasis has failed. A variety of endoscopic techniques have been employed to stop bleeding and reduce the risk of rebleeding, with no major differences in outcome between these methods. These include injection therapy, fibrin injection, heater probe, mono polar electrocautery, bipolar electrocautery, lasers and mechanical hemo clipping. The most important factor in determining outcome after gastrointestinal bleeding is rebleeding or persistent bleeding. The endoscopic appearance of an ulcer, however, provides the most useful prognostic information for bleeding. Recurrent bleeding after initial endoscopic hemostasis occurs in 15-20% of patients with a bleeding peptic ulcer. The best approach to these patients remains controversial; the current options are repeat endoscopic therapy with the same or a different technique, emergency surgery or semi elective surgery after repeat endoscopic hemostasis. The combination of epinephrine injection with thermal coagulation may be more effective than epinephrine injection alone. Newer modalities such as fibrin injection or the application of hemo clips appear promising and comparative studies are awaited. (author)
Per-oral endoscopic myotomy: Major advance in achalasia treatment and in endoscopic surgery
Friedel, David; Modayil, Rani; Stavropoulos, Stavros N
2014-01-01
Per-oral endoscopic myotomy (POEM) represents a natural orifice endoscopic surgery (NOTES) approach to laparoscopy Heller myotomy (LHM). POEM is arguably the most successful clinical application of NOTES. The growth of POEM from a single center in 2008 to approximately 60 centers worldwide in 2014 with several thousand procedures having been performed attests to the success of POEM. Initial efficacy, safety and acid reflux data suggest at least equivalence of POEM to LHM, the previous gold standard for achalasia therapy. Adjunctive techniques used in the West include impedance planimetry for real-time intraprocedural luminal assessment and endoscopic suturing for challenging mucosal defect closures during POEM. The impact of POEM extends beyond the realm of esophageal motility disorders as it is rapidly popularizing endoscopic submucosal dissection in the West and spawning offshoots that use the submucosal tunnel technique for a host of new indications ranging from resection of tumors to pyloromyotomy for gastroparesis. PMID:25548473
Endoscopic tissue diagnosis of cholangiocarcinoma.
LENUS (Irish Health Repository)
Harewood, Gavin C
2008-09-01
The extremely poor outcome in patients with cholangiocarcinoma, in large part, reflects the late presentation of these tumors and the challenging nature of establishing a tissue diagnosis. Establishing a diagnosis of cholangiocarcinoma requires obtaining evidence of malignancy from sampling of the epithelium of the biliary tract, which has proven to be challenging. Although endoscopic ultrasound-guided fine needle aspiration performs slightly better than endoscopic retrograde cholangiopancreatography in diagnosing cholangiocarcinoma, both endoscopic approaches demonstrate disappointing performance characteristics.
Thermal Stress FE Analysis of Large-scale Gas Holder Under Sunshine Temperature Field
Li, Jingyu; Yang, Ranxia; Wang, Hehui
2018-03-01
The temperature field and thermal stress of Man type gas holder is simulated by using the theory of sunshine temperature field based on ASHRAE clear-sky model and the finite element method. The distribution of surface temperature and thermal stress of gas holder under the given sunshine condition is obtained. The results show that the thermal stress caused by sunshine can be identified as one of the important factors for the failure of local cracked oil leakage which happens on the sunny side before on the shady side. Therefore, it is of great importance to consider the sunshine thermal load in the stress analysis, design and operation of large-scale steel structures such as the gas holder.
Cultural Robotics: The Culture of Robotics and Robotics in Culture
Directory of Open Access Journals (Sweden)
Hooman Samani
2013-12-01
Full Text Available In this paper, we have investigated the concept of “Cultural Robotics” with regard to the evolution of social into cultural robots in the 21st Century. By defining the concept of culture, the potential development of a culture between humans and robots is explored. Based on the cultural values of the robotics developers, and the learning ability of current robots, cultural attributes in this regard are in the process of being formed, which would define the new concept of cultural robotics. According to the importance of the embodiment of robots in the sense of presence, the influence of robots in communication culture is anticipated. The sustainability of robotics culture based on diversity for cultural communities for various acceptance modalities is explored in order to anticipate the creation of different attributes of culture between robots and humans in the future.
Current Status of Peroral Endoscopic Myotomy
Cho, Young Kwan; Kim, Seong Hwan
2018-01-01
Peroral endoscopic myotomy (POEM) has been established as an optional treatment for achalasia. POEM is an endoluminal procedure that involves dissection of esophageal muscle fibers followed by submucosal tunneling. Inoue first attempted to use POEM for the treatment of achalasia in humans. Expanded indications of POEM include classic indications such as type I, type II, type III achalasia, failed prior treatments, including Botulinum toxin injection, endoscopic balloon dilation, laparoscopic Heller myotomy, and hypertensive motor disorders such as diffuse esophageal spasm, jackhammer esophagus. Contraindications include prior radiation therapy to the esophagus and prior extensive esophageal mucosal resection/ablation involving the POEM field. Most of the complications are minor and self-limited and can be managed conservatively. As POEM emerged as the main treatment for achalasia, various adaptations to tunnel endoscopic surgery have been attempted. Tunnel endoscopic surgery includes POEM, peroral endoscopic tumor resection, gastric peroral endoscopic pyloromyotomy. POEM has been widely accepted as a treatment for all types of achalasia, even for specific cases such as achalasia with failed prior treatments, and hypertensive motor disorders. PMID:29397656
Current Status of Peroral Endoscopic Myotomy.
Cho, Young Kwan; Kim, Seong Hwan
2018-01-01
Peroral endoscopic myotomy (POEM) has been established as an optional treatment for achalasia. POEM is an endoluminal procedure that involves dissection of esophageal muscle fibers followed by submucosal tunneling. Inoue first attempted to use POEM for the treatment of achalasia in humans. Expanded indications of POEM include classic indications such as type I, type II, type III achalasia, failed prior treatments, including Botulinum toxin injection, endoscopic balloon dilation, laparoscopic Heller myotomy, and hypertensive motor disorders such as diffuse esophageal spasm, jackhammer esophagus. Contraindications include prior radiation therapy to the esophagus and prior extensive esophageal mucosal resection/ablation involving the POEM field. Most of the complications are minor and self-limited and can be managed conservatively. As POEM emerged as the main treatment for achalasia, various adaptations to tunnel endoscopic surgery have been attempted. Tunnel endoscopic surgery includes POEM, peroral endoscopic tumor resection, gastric peroral endoscopic pyloromyotomy. POEM has been widely accepted as a treatment for all types of achalasia, even for specific cases such as achalasia with failed prior treatments, and hypertensive motor disorders.
Current Status of Peroral Endoscopic Myotomy
Directory of Open Access Journals (Sweden)
Young Kwan Cho
2018-01-01
Full Text Available Peroral endoscopic myotomy (POEM has been established as an optional treatment for achalasia. POEM is an endoluminal procedure that involves dissection of esophageal muscle fibers followed by submucosal tunneling. Inoue first attempted to use POEM for the treatment of achalasia in humans. Expanded indications of POEM include classic indications such as type I, type II, type III achalasia, failed prior treatments, including Botulinum toxin injection, endoscopic balloon dilation, laparoscopic Heller myotomy, and hypertensive motor disorders such as diffuse esophageal spasm, jackhammer esophagus. Contraindications include prior radiation therapy to the esophagus and prior extensive esophageal mucosal resection/ablation involving the POEM field. Most of the complications are minor and self-limited and can be managed conservatively. As POEM emerged as the main treatment for achalasia, various adaptations to tunnel endoscopic surgery have been attempted. Tunnel endoscopic surgery includes POEM, peroral endoscopic tumor resection, gastric peroral endoscopic pyloromyotomy. POEM has been widely accepted as a treatment for all types of achalasia, even for specific cases such as achalasia with failed prior treatments, and hypertensive motor disorders.
Ross, Peter D; Steven, Richard; Zhang, Dong; Li, Heng; Abel, Eric W
2015-11-01
This study was undertaken to introduce and establish the value of the Dundee Endoscopic Psychomotor Otolaryngology Surgery Trainer (DEPOST) as a customisable, objective real-time scoring system for trainee assessment. The construct validity of the system was assessed by comparing the performance of experienced otolaryngologists with that of otolaryngology trainees, junior doctors and medical students. Forty two subjects (13 Consultants, 8 senior trainees, 13 junior trainees and 8 junior doctors/medical students) completed a single test on DEPOST. The test involved using a 30° rigid endoscope and a probe with position sensor, to identify a series of lights in a complex 3-dimensional model. The system scored subjects for time, success rate, and economy of movement (distance travelled). An analysis of variance and correlation analysis were used for the data analysis, with statistical significance set at 0.05. Increasing experience led to significantly improved performance with the DEPOST (p < 0.01). Senior trainees' results were significantly better than those of consultant otolaryngologists in success rate and time (p < 0.05 & p < 0.05). Consultants were the most efficient in their movement (p = 0.051) CONCLUSIONS: The system provides an accurate and customisable assessment of endoscopic skill in otolaryngologists. The DEPOST system has construct validity, with master surgeons and senior trainees completing the tasks more accurately without sacrificing execution time, success rate or efficiency of movement.
Friendly network robotics; Friendly network robotics
Energy Technology Data Exchange (ETDEWEB)
NONE
1997-03-01
This paper summarizes the research results on the friendly network robotics in fiscal 1996. This research assumes an android robot as an ultimate robot and the future robot system utilizing computer network technology. The robot aiming at human daily work activities in factories or under extreme environments is required to work under usual human work environments. The human robot with similar size, shape and functions to human being is desirable. Such robot having a head with two eyes, two ears and mouth can hold a conversation with human being, can walk with two legs by autonomous adaptive control, and has a behavior intelligence. Remote operation of such robot is also possible through high-speed computer network. As a key technology to use this robot under coexistence with human being, establishment of human coexistent robotics was studied. As network based robotics, use of robots connected with computer networks was also studied. In addition, the R-cube (R{sup 3}) plan (realtime remote control robot technology) was proposed. 82 refs., 86 figs., 12 tabs.
Robot vision for nuclear advanced robot
International Nuclear Information System (INIS)
Nakayama, Ryoichi; Okano, Hideharu; Kuno, Yoshinori; Miyazawa, Tatsuo; Shimada, Hideo; Okada, Satoshi; Kawamura, Astuo
1991-01-01
This paper describes Robot Vision and Operation System for Nuclear Advanced Robot. This Robot Vision consists of robot position detection, obstacle detection and object recognition. With these vision techniques, a mobile robot can make a path and move autonomously along the planned path. The authors implemented the above robot vision system on the 'Advanced Robot for Nuclear Power Plant' and tested in an environment mocked up as nuclear power plant facilities. Since the operation system for this robot consists of operator's console and a large stereo monitor, this system can be easily operated by one person. Experimental tests were made using the Advanced Robot (nuclear robot). Results indicate that the proposed operation system is very useful, and can be operate by only person. (author)
Ambusam, S; Baharudin, O; Roslizawati, N; Leonard, J
2015-01-01
Document holder is used as a remedy to address occupational neck pain among computer users. An understanding on the effects of the document holder along with other work related risk factors while working in computer workstation requires attention. A comprehensive knowledge on the optimal location of the document holder in computer use and associated work related factors that may contribute to neck pain reviewed in this article. A literature search has been conducted over the past 14 years based on the published articles from January 1990 to January 2014 in both Science Direct and PubMed databases. Medical Subject Headings (MeSH) keywords for search were neck muscle OR head posture OR muscle tension' OR muscle activity OR work related disorders OR neck pain AND/OR document location OR document holder OR source document OR copy screen holder.Document holder placed lateral to the screen was most preferred to reduce neck discomfort among occupational typists. Document without a holder was placed flat on the surface is least preferred. The head posture and muscle activity increases when the document is placed flat on the surface compared to when placed on the document holder. Work related factors such as static posture, repetitive movement, prolong sitting and awkward positions were the risk factors for chronic neck pain. This review highlights the optimal location for document holder for computer users to reduce neck pain. Together, the importance of work related risk factors for to neck pain on occupational typist is emphasized for the clinical management.
New trends in minimally invasive urological surgery: what is beyond the robot?
Micali, Salvatore; Pini, Giovannalberto; Teber, Dogu; Sighinolfi, Maria Chiara; De Stefani, Stefano; Bianchi, Giampaolo; Rassweiler, Jens
2013-06-01
To review the minimal-invasive development of surgical technique in urology focusing on nomenclature, history and outcomes of Laparo-Endoscopic Single-site Surgery (LESS), Natural Orifice Translumenal Endoscopic Surgery (NOTES) and Computer-Assisted Surgery (CAS). A comprehensive literature search was conducted in order to find article related to LESS, NOTES and CAS in urology. The most relevant papers over the last 10 years were selected in base to the experience from the panel of experts, journal, authorship and/or content. Seven hundred and fifty manuscripts were found. Papers on LESS describe feasibility/safety in most of the procedures with a clinical experience of more than 300 cases and five compared results to standard laparoscopy without showing significant differences. NOTES accesses have been proved their feasibility/safety in experimental study. In human, the only procedures performed are on kidney and through a hybrid-Transvaginal route. New robots overcome the main drawbacks of the DaVinci® platform. The use of CAS is increasing its popularity in urology. LESS has been applied in clinical practice, but only ongoing technical and instrumental refinement will define its future role and overall benefit. The transition to a clinical application of NOTES seems at present only possible with multiple NOTES access and transvaginal access. Robot and Soft Tissue Navigation appear to be important to improve surgical skills. We are already witness to the advantages offered by the former even if costs need to be redefined based on pending long-term results. The latter will probably upgrade the quality of surgery in a near future.
Laser assisted robotic surgery in cornea transplantation
Rossi, Francesca; Micheletti, Filippo; Magni, Giada; Pini, Roberto; Menabuoni, Luca; Leoni, Fabio; Magnani, Bernardo
2017-03-01
Robotic surgery is a reality in several surgical fields, such as in gastrointestinal surgery. In ophthalmic surgery the required high spatial precision is limiting the application of robotic system, and even if several attempts have been designed in the last 10 years, only some application in retinal surgery were tested in animal models. The combination of photonics and robotics can really open new frontiers in minimally invasive surgery, improving the precision, reducing tremor, amplifying scale of motion, and automating the procedure. In this manuscript we present the preliminary results in developing a vision guided robotic platform for laser-assisted anterior eye surgery. The robotic console is composed by a robotic arm equipped with an "end effector" designed to deliver laser light to the anterior corneal surface. The main intended application is for laser welding of corneal tissue in laser assisted penetrating keratoplasty and endothelial keratoplasty. The console is equipped with an integrated vision system. The experiment originates from a clear medical demand in order to improve the efficacy of different surgical procedures: when the prototype will be optimized, other surgical areas will be included in its application, such as neurosurgery, urology and spinal surgery.
Zhang, Wen-Gang; Linghu, En-Qiang; Chai, Ning-Li; Li, Hui-Kai
2017-05-14
To verify the hypothesis that the Ling classification describes the endoscopic progressive process of achalasia and determine the ability of successful peroral endoscopic myotomy (POEM) to prevent endoscopic progression of achalasia. We retrospectively reviewed the endoscopic findings, symptom duration, and manometric data in patients with achalasia. A total of 359 patients (197 women, 162 men) with a mean age of 42.1 years (range, 12-75 years) were evaluated. Symptom duration ranged from 2 to 360 mo, with a median of 36 mo. Patients were classified with Ling type I ( n = 119), IIa ( n = 106), IIb ( n = 60), IIc ( n = 60), or III ( n = 14), according to the Ling classification. Of the 359 patients, 349 underwent POEM, among whom 21 had an endoscopic follow-up for more than 2 years. Pre-treatment and post-treatment Ling classifications of these 21 patients were compared. Symptom duration increased significantly with increasing Ling classification (from I to III) ( P achalasia and may be able to serve as an endoscopic assessment criterion for achalasia. Successful POEM (Eckardt score ≤ 3) seems to have the ability to prevent endoscopic evolvement of achalasia. However, studies with larger populations are warranted to confirm our findings.
21 CFR 884.4100 - Endoscopic electrocautery and accessories.
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endoscopic electrocautery and accessories. 884... Surgical Devices § 884.4100 Endoscopic electrocautery and accessories. (a) Identification. An endoscopic electrocautery is a device used to perform female sterilization under endoscopic observation. It is designed to...
Magnetic air capsule robotic system: proof of concept of a novel approach for painless colonoscopy.
Valdastri, P; Ciuti, G; Verbeni, A; Menciassi, A; Dario, P; Arezzo, A; Morino, M
2012-05-01
Despite being considered the most effective method for colorectal cancer diagnosis, colonoscopy take-up as a mass-screening procedure is limited mainly due to invasiveness, patient discomfort, fear of pain, and the need for sedation. In an effort to mitigate some of the disadvantages associated with colonoscopy, this work provides a preliminary assessment of a novel endoscopic device consisting in a softly tethered capsule for painless colonoscopy under robotic magnetic steering. The proposed platform consists of the endoscopic device, a robotic unit, and a control box. In contrast to the traditional insertion method (i.e., pushing from behind), a "front-wheel" propulsion approach is proposed. A compliant tether connecting the device to an external box is used to provide insufflation, passing a flexible operative tool, enabling lens cleaning, and operating the vision module. To assess the diagnostic and treatment ability of the platform, 12 users were asked to find and remove artificially implanted beads as polyp surrogates in an ex vivo model. In vivo testing consisted of a qualitative study of the platform in pigs, focusing on active locomotion, diagnostic and therapeutic capabilities, safety, and usability. The mean percentage of beads identified by each user during ex vivo trials was 85 ± 11%. All the identified beads were removed successfully using the polypectomy loop. The mean completion time for accomplishing the entire procedure was 678 ± 179 s. No immediate mucosal damage, acute complications such as perforation, or delayed adverse consequences were observed following application of the proposed method in vivo. Use of the proposed platform in ex vivo and preliminary animal studies indicates that it is safe and operates effectively in a manner similar to a standard colonoscope. These studies served to demonstrate the platform's added advantages of reduced size, front-wheel drive strategy, and robotic control over locomotion and orientation.
da Vinci robot-assisted keyhole neurosurgery: a cadaver study on feasibility and safety.
Marcus, Hani J; Hughes-Hallett, Archie; Cundy, Thomas P; Yang, Guang-Zhong; Darzi, Ara; Nandi, Dipankar
2015-04-01
The goal of this cadaver study was to evaluate the feasibility and safety of da Vinci robot-assisted keyhole neurosurgery. Several keyhole craniotomies were fashioned including supraorbital subfrontal, retrosigmoid and supracerebellar infratentorial. In each case, a simple durotomy was performed, and the flap was retracted. The da Vinci surgical system was then used to perform arachnoid dissection towards the deep-seated intracranial cisterns. It was not possible to simultaneously pass the 12-mm endoscope and instruments through the keyhole craniotomy in any of the approaches performed, limiting visualization. The articulated instruments provided greater dexterity than existing tools, but the instrument arms could not be placed in parallel through the keyhole craniotomy and, therefore, could not be advanced to the deep cisterns without significant clashing. The da Vinci console offered considerable ergonomic advantages over the existing operating room arrangement, allowing the operating surgeon to remain non-sterile and seated comfortably throughout the procedure. However, the lack of haptic feedback was a notable limitation. In conclusion, while robotic platforms have the potential to greatly enhance the performance of transcranial approaches, there is strong justification for research into next-generation robots, better suited to keyhole neurosurgery.
Directory of Open Access Journals (Sweden)
Luke Jai Wood
Full Text Available Robots have been used in a variety of education, therapy or entertainment contexts. This paper introduces the novel application of using humanoid robots for robot-mediated interviews. An experimental study examines how children's responses towards the humanoid robot KASPAR in an interview context differ in comparison to their interaction with a human in a similar setting. Twenty-one children aged between 7 and 9 took part in this study. Each child participated in two interviews, one with an adult and one with a humanoid robot. Measures include the behavioural coding of the children's behaviour during the interviews and questionnaire data. The questions in these interviews focused on a special event that had recently taken place in the school. The results reveal that the children interacted with KASPAR very similar to how they interacted with a human interviewer. The quantitative behaviour analysis reveal that the most notable difference between the interviews with KASPAR and the human were the duration of the interviews, the eye gaze directed towards the different interviewers, and the response time of the interviewers. These results are discussed in light of future work towards developing KASPAR as an 'interviewer' for young children in application areas where a robot may have advantages over a human interviewer, e.g. in police, social services, or healthcare applications.
Robotic approaches for rehabilitation of hand function after stroke.
Lum, Peter S; Godfrey, Sasha B; Brokaw, Elizabeth B; Holley, Rahsaan J; Nichols, Diane
2012-11-01
The goal of this review was to discuss the impairments in hand function after stroke and present previous work on robot-assisted approaches to movement neurorehabilitation. Robotic devices offer a unique training environment that may enhance outcomes beyond what is possible with conventional means. Robots apply forces to the hand, allowing completion of movements while preventing inappropriate movement patterns. Evidence from the literature is emerging that certain characteristics of the human-robot interaction are preferable. In light of this evidence, the robotic hand devices that have undergone clinical testing are reviewed, highlighting the authors' work in this area. Finally, suggestions for future work are offered. The ability to deliver therapy doses far higher than what has been previously tested is a potentially key advantage of robotic devices that needs further exploration. In particular, more efforts are needed to develop highly motivating home-based devices, which can increase access to high doses of assisted movement therapy.
Laser driven white light source for BRDF measurement
DEFF Research Database (Denmark)
Amdemeskel, Mekbib Wubishet; Thorseth, Anders; Dam-Hansen, Carsten
2017-01-01
In this paper, we will present a setup with laser driven light source (LDLS) for measuring a 2D bidirectional reflectance distribution function (BRDF). We have carried out measurements to acquire the BRDF of different samples based on our setup: which consists of a new laser driven broadband light...... source (UV-VIS-NIR), spectroradiometer and sample holder stepper motor in a dark UV-protected environment. Here, we introduced a special kind of light source which has a bright, stable, broad spectral range and well collimated light output to give a very good angular resolution. The experimental results...
Gender differentials in market participation among small-holder ...
African Journals Online (AJOL)
Gender differentials in market participation among small-holder cassava farmers ... The results showed that the female farmers participated and sold more cassava in the market than their male counterparts. ... facilitate faster delivery of farm produce especially perishable commodities such as ... AJOL African Journals Online.
Energy Technology Data Exchange (ETDEWEB)
Eisenstein, Alon; Goh, M. Cynthia [Department of Chemistry and Institute for Optical Sciences, University of Toronto, 80 St. George Street, Toronto M5S 3H6 (Canada)
2012-03-15
A novel sample holder that enables atomic force microscopy (AFM) tips to be mounted inside a scanning electron microscopy (SEM) for the purpose of characterizing the AFM tips is described. The holder provides quick and easy handling of tips by using a spring clip to hold them in place. The holder can accommodate two tips simultaneously in two perpendicular orientations, allowing both top and side view imaging of the tips by the SEM.
The technology of mobile robot with articulated crawler mechanism
Energy Technology Data Exchange (ETDEWEB)
Kim, Seung Ho; Kim, Byung Soo; Kim, Chang Hoi; Hwang, Suk Yong; Suh, Yong Chil; Lee, Yung Kwang; Sin, Jae Ho [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)
1995-01-01
The main application of a mobile robot are to do the inspection and maintenance tasks in the primary and auxiliary building, and to meet with the radiological emergency response in nuclear power plant. Our project to develop crawler-type mobile robot has been divided into 3 phases. In 1 st phase, the-state-of-the-arts of mobile robot technology were studied and analyzed. And then the technical report `development of mobile robot technology for the light work` was published on July, 1993. In current phase, the articulated crawler type mobile robot named as ANDROS Mark VI was purchased to evaluate deeply its mechanism and control system. Then we designed the autonomous track surface, to get the inclination angle of robot, and to control the front and rear auxiliary track autonomously during climbing up and down stairs. And also, the autonomous stair-climbing algorithm has been developed to going over stairs with high stability. For the final phase, the advanced model of articulated crawler type mobile robot is going to be developed. (Author) 13 refs., 30 figs., 12 tabs.
The technology of mobile robot with articulated crawler mechanism
International Nuclear Information System (INIS)
Kim, Seung Ho; Kim, Byung Soo; Kim, Chang Hoi; Hwang, Suk Yong; Suh, Yong Chil; Lee, Yung Kwang; Sin, Jae Ho
1995-01-01
The main application of a mobile robot are to do the inspection and maintenance tasks in the primary and auxiliary building, and to meet with the radiological emergency response in nuclear power plant. Our project to develop crawler-type mobile robot has been divided into 3 phases. In 1 st phase, the-state-of-the-arts of mobile robot technology were studied and analyzed. And then the technical report 'development of mobile robot technology for the light work' was published on July, 1993. In current phase, the articulated crawler type mobile robot named as ANDROS Mark VI was purchased to evaluate deeply its mechanism and control system. Then we designed the autonomous track surface, to get the inclination angle of robot, and to control the front and rear auxiliary track autonomously during climbing up and down stairs. And also, the autonomous stair-climbing algorithm has been developed to going over stairs with high stability. For the final phase, the advanced model of articulated crawler type mobile robot is going to be developed. (Author) 13 refs., 30 figs., 12 tabs
Investigation of a flame holder geometry effect on flame structure in non-premixed combustion
International Nuclear Information System (INIS)
Hashemi, S. A.; Hajialigol, N.; Fattahi, A.; Heydari, R.; Mazaheri, K.
2013-01-01
In this paper the effect of flame holder geometry on flame structure is studied. The obtained numerical results using realizable k-ε and β-PDF models show a good agreement with experimental data. The results show that increasing in flame holder length decreases flame length and increases flame temperature. Additionally, it is observed that flame lengths decrease by increasing in flame holder radius and increase for larger radii. Furthermore in various radii, the flame temperature is higher for smaller flame lengths. It was found that behavior of flame structure is mainly affected by the mass flow rate of hot gases that come near the reactant by the recirculation zone.
Investigation of a flame holder geometry effect on flame structure in non-premixed combustion
Energy Technology Data Exchange (ETDEWEB)
Hashemi, S. A.; Hajialigol, N.; Fattahi, A.; Heydari, R. [University of Kashan, Kashan (Iran, Islamic Republic of); Mazaheri, K. [University of Tarbiat Moddares, Tehran (Iran, Islamic Republic of)
2013-11-15
In this paper the effect of flame holder geometry on flame structure is studied. The obtained numerical results using realizable k-ε and β-PDF models show a good agreement with experimental data. The results show that increasing in flame holder length decreases flame length and increases flame temperature. Additionally, it is observed that flame lengths decrease by increasing in flame holder radius and increase for larger radii. Furthermore in various radii, the flame temperature is higher for smaller flame lengths. It was found that behavior of flame structure is mainly affected by the mass flow rate of hot gases that come near the reactant by the recirculation zone.
DEFF Research Database (Denmark)
Meining, A; Feussner, H; Swain, P
2011-01-01
The fourth Euro-NOTES workshop took place in September 2010 and focused on enabling intensive scientific dialogue and interaction between participants to discuss the state of the practice and development of natural-orifice transluminal endoscopic surgery (NOTES) in Europe. Five working groups were...... collaboration and indications, robotics and platforms, and matters related to training and education. This review summarizes consensus statements of the working groups to give an overview of what has been achieved so far and what might be relevant for research related to NOTES in the near future....
Endoscopic management of hilar biliary strictures
Singh, Rajiv Ranjan; Singh, Virendra
2015-01-01
Hilar biliary strictures are caused by various benign and malignant conditions. It is difficult to differentiate benign and malignant strictures. Postcholecystectomy benign biliary strictures are frequently encountered. Endoscopic management of these strictures is challenging. An endoscopic method has been advocated that involves placement of increasing number of stents at regular intervals to resolve the stricture. Malignant hilar strictures are mostly unresectable at the time of diagnosis and only palliation is possible.Endoscopic palliation is preferred over surgery or radiological intervention. Magnetic resonance cholangiopancreaticography is quite important in the management of these strictures. Metal stents are superior to plastic stents. The opinion is divided over the issue of unilateral or bilateral stenting.Minimal contrast or no contrast technique has been advocated during endoscopic retrograde cholangiopancreatography of these patients. The role of intraluminal brachytherapy, intraductal ablation devices, photodynamic therapy, and endoscopic ultrasound still remains to be defined. PMID:26191345
Welding robot package; Arc yosetsu robot package
Energy Technology Data Exchange (ETDEWEB)
Nishikawa, S. [Yaskawa Electric Corp., Kitakyushu (Japan)
1998-09-01
For the conventional high-speed welding robot, the welding current was controlled mainly for reducing the spatters during short circuits and for stabilizing the beads by the periodic short circuits. However, an increase of deposition amount in response to the speed is required for the high-speed welding. Large-current low-spatter welding current region control was added. Units were integrated into a package by which the arc length is kept in short without dispersion of arc length for welding without defects such as undercut and unequal beads. In automobile industry, use of aluminum parts is extended for the light weight. The welding is very difficult, and automation is not so progressing in spite of the poor environment. Buckling of welding wire is easy to occur, and supply of wire is obstructed by the deposition of chipped powders on the torch cable, which stay within the contact chip resulting in the deposition. Dislocation of locus is easy to occur at the corner of rectangular pipe during the welding. By improving these troubles, an aluminum MIG welding robot package has been developed. 13 figs.
Stability of Cortisol and Cortisone in Human Breast Milk During Holder Pasteurization.
van der Voorn, Bibian; de Waard, Marita; Dijkstra, Lisette R; Heijboer, Annemieke C; Rotteveel, Joost; van Goudoever, Johannes B; Finken, Martijn J J
2017-12-01
Human donor milk is the feeding of choice for preterm infants, when own mother's milk is not available. Holder pasteurization is necessary to secure the safety of donor milk, although it can affect milk quality by reduction of nutritional and bioactive components. Recently, research has focused on the potential role of breast milk glucocorticoids for infant development. At this moment, it is unknown whether pasteurization affects milk glucocorticoid levels. Therefore, we assessed whether Holder pasteurization, the most frequently used method nowadays, reduces breast milk cortisol and cortisone levels, using breast milk samples from 30 women who delivered at term. We found tight correlations between pre- and postpasteurization levels of cortisol (R = 0.99) and cortisone (R = 0.98), and good agreement in Passing and Bablok regression analysis. In conclusion, cortisol and cortisone in human term breast milk are not significantly affected by Holder pasteurization.
Cognitive and sociocultural aspects of robotized technology: innovative processes of adaptation
Kvesko, S. B.; Kvesko, B. B.; Kornienko, M. A.; Nikitina, Y. A.; Pankova, N. M.
2018-05-01
The paper dwells upon interaction between socio-cultural phenomena and cognitive characteristics of robotized technology. The interdisciplinary approach was employed in order to cast light on the manifold and multilevel identity of scientific advance in terms of robotized technology within the mental realm. Analyzing robotized technology from the viewpoint of its significance for the modern society is one of the upcoming trends in the contemporary scientific realm. The robots under production are capable of interacting with people; this results in a growing necessity for the studies on social status of robotized technological items. Socio-cultural aspect of cognitive robotized technology is reflected in the fact that the nature becomes ‘aware’ of itself via human brain, a human being tends to strives for perfection in their intellectual and moral dimensions.
Measuring the Latency of an Augmented Reality System for Robot-Assisted Minimally Invasive Surgery
DEFF Research Database (Denmark)
Jørgensen, Martin Kibsgaard; Kraus, Martin
2017-01-01
visual communication in training for robot-assisted minimally invasive surgery with da Vinci surgical systems. To make sure that our augmented reality system provides the best possible user experience, we investigated the video latency of the da Vinci surgical system and how the components of our system...... affect the overall latency. To measure the photon-to-photon latency, we used a microcontroller to determine the time between the activation of a lightemitting diode in front of the endoscopic camera and the corresponding increase in intensity of the surgeon's display as measured by a phototransistor...
Endoscopic transmission of Helicobacter pylori
Tytgat, G. N.
1995-01-01
The contamination of endoscopes and biopsy forceps with Helicobacter pylori occurs readily after endoscopic examination of H. pylori-positive patients. Unequivocal proof of iatrogenic transmission of the organism has been provided. Estimates for transmission frequency approximate to 4 per 1000
Popov, E. P.; Iurevich, E. I.
The history and the current status of robotics are reviewed, as are the design, operation, and principal applications of industrial robots. Attention is given to programmable robots, robots with adaptive control and elements of artificial intelligence, and remotely controlled robots. The applications of robots discussed include mechanical engineering, cargo handling during transportation and storage, mining, and metallurgy. The future prospects of robotics are briefly outlined.
Research Amplitudo Vibration On Holder Due To The Process Of Lathe Nozzle Rocket RX 450
Ediwan; Budi Djatmiko, Agus; Dody Arisandi, EfFendy; Purnomo, Heri; Ibadi, Mahfud
2018-04-01
The main function of the rocket nozzle is to convert the enthalpy efficiency from combustion gas to kinetic energy and also to make high velocity out of the gas. The rocket nozzle usually consists of a converging and diverging part. With a smaller area on the neck and enlarged at the exit area. The velocity flow through the nozzle enlarges into the speed of sound through the neck and then becomes super sonic in the divergent part. Nozzle making or machining using conventional lathes, first performed is drilling on a massive metal that is bonded to the veneer, then after a sufficient gap is done deep-boring. At the time of the process of lathe in the nozzle RX 450 there is an obstacle that is vibrating tool holder chisel or holder so it is worried about not precision of the process of lathe. This should not happen because it can cause failure in the latter for it needs to be studied and studied further so that the lathe process goes accordingly. The holder material of ST 60 with a modulus of elasticity 200 GPa and a nozzle material of AISI 4340 alloy steel with σyield = 470 MPa, Shear Modulus G = 80 GPa. The purpose of this research is to observe the amplitude of vibration on the holder due to RX- 450 nozzle lathe processing for the purpose of amplitude that occurs in accordance with the desired so that the nozzle structure is no damage process. The result of the research was obtained holder with length (L) 80cm, profile width (B) 5 cm, height of profile (H) 10 cm, turning machine ω = 8.98 rad / sec and natural holder frequency ωn = 89.8 rad / second, Amplitude of vibration of δ = 1.21 mm, while the amplitude of the design X = 1.22 mm From the results of this study it can be said that the holder of a chisel or holder can be used as a tool at the time of RX nozzle retrieval process and is quite safe because it works under the condition ω/ω n Rocket Payload "AKPV Engineering University of Wyoming 2009 )
Campo, Rudi; Wattiez, Arnaud; Tanos, Vasilis; Di Spiezio Sardo, Attilio; Grimbizis, Grigoris; Wallwiener, Diethelm; Brucker, Sara; Puga, Marco; Molinas, Roger; O'Donovan, Peter; Deprest, Jan; Van Belle, Yves; Lissens, Ann; Herrmann, Anja; Tahir, Mahmood; Benedetto, Chiara; Siebert, Igno; Rabischong, Benoit; De Wilde, Rudy Leon
2016-04-01
In recent years, training and education in endoscopic surgery has been critically reviewed. Clinicians, both surgeons as gynaecologist who perform endoscopic surgery without proper training of the specific psychomotor skills are at higher risk to increased patient morbidity and mortality. Although the apprentice-tutor model has long been a successful approach for training of surgeons, recently, clinicians have recognised that endoscopic surgery requires an important training phase outside the operating theatre. The Gynaecological Endoscopic Surgical Education and Assessment programme (GESEA), recognises the necessity of this structured approach and implements two separated stages in its learning strategy. In the first stage, a skill certificate on theoretical knowledge and specific practical psychomotor skills is acquired through a high stake exam; in the second stage, a clinical programme is completed to achieve surgical competence and receive the corresponding diploma. Three diplomas can be awarded: (a) the Bachelor in Endoscopy; (b) the Minimally Invasive Gynaecological Surgeon (MIGS); and (c) the Master level. The Master level is sub-divided into two separate diplomas: the Master in Laparoscopic Pelvic Surgery and the Master in Hysteroscopy. The complexity of modern surgery has increased the demands and challenges to surgical education and the quality control. This programme is based on the best available scientific evidence and it counteracts the problem of the traditional surgical apprentice tutor model. It is seen as a major step toward standardization of endoscopic surgical training in general. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
New trends in medical and service robots challenges and solutions
Pisla, Doina; Bleuler, Hannes
2014-01-01
This volume describes new frontiers in medical and service robotics in the light of recent developments in technology to advance robot design and implementation. In particular, the work looks at advances in design, development and implementation of contemporary surgical, rehabilitation and biorobots. Surgical robots allow surgeons greater access to areas under operation using more precise and less invasive methods. Rehabilitation robots facilitate and support the lives of the infirm, elderly people, or those with dysfunction of body parts affecting movement. These robots are also used for rehabilitation and related procedures, such as training and therapy. Biorobots are designed to imitate the cognition of humans and animals. The need to substitute humans working on delicate, tiresome and monotonous tasks, or working with potentially health-damaging toxic materials, requires intelligent, high-performance service robots with the ability to cooperate, advanced communication and sophisticated perception and cogn...
The French A.E.C. nuclear robotic program
International Nuclear Information System (INIS)
Foult, T.
1991-01-01
The new French nuclear robotic program launched by the CEA was started at the beginning of 1988 for the duration of two years and with the total subsidy of about 130 million French franc. This program includes the following four steps: the definition of model missions dedicated to inspection and intervention in nuclear environment, the system analysis to define the systems, functions and specifications required to perform these model missions, the technological development required to achieve these systems, and the design of demonstration models with the partial integration of the above developments. The whole program including these four steps is called SYROCO (modular SYstem for RObots COoperating in radioactive environment). The repair of leak in a pipe in a reprocessing cell, the model mission in a PWR nuclear power plant, autonomous load bearing mobile robots, squirrel concept light modular carrier concept, radiation hardening, mechanic, perception of environment, communication, control and simulation and the demonstration models are described. SHERPA project, perception management, force controlled manipulator, squirrel project, light modular carrier, processes and NAB model mission simulation are particularly mentioned
Endoscopic Medial Maxillectomy Breaking New Frontiers
Mohanty, Sanjeev; Gopinath, M.
2011-01-01
Endoscopy has changed the perspective of rhinologist towards the nose. It has revolutionised the surgical management of sinonasal disorders. Sinus surgeries were the first to get the benefit of endoscope. Gradually the domain of endoscopic surgery extended to the management of sino nasal tumours. Traditionally medial maxillectomy was performed through lateral rhinotomy or mid facial degloving approach. Endoscopic medial maxillectomy has been advocated by a number of authors in the management ...
Fyock, Christopher J; Forsmark, Chris E; Wagh, Mihir S
2011-01-01
Natural orifice translumenal endoscopic surgery (NOTES) has recently gained great enthusiasm, but there is concern regarding the ability to endoscopically manage complications purely via natural orifices. To assess the feasibility of endoscopically managing enteral perforation during NOTES using currently available endoscopic accessories. Twelve pigs underwent transgastric or transcolonic endoscopic exploration. Full-thickness enterotomies were intentionally created to mimic accidental small bowel lacerations during NOTES. These lacerations were then closed with endoclips. In the blinded arm of the study, small bowel repair was performed by a second blinded endoscopist. Adequate closure of the laceration was confirmed with a leak test. Primary access sites were closed with endoclips or T-anchors. At necropsy, the peritoneal cavity was inspected for abscesses, bleeding, or damage to surrounding structures. The enterotomy site was examined for adequacy of closure, adhesions, or evidence of infection. Fifteen small bowel lacerations were performed in 12 animals. Successful closure was achieved in all 10 cases in the nonblinded arm. Survival animals had an uncomplicated postoperative course and all enterotomy sites were well healed without evidence of necrosis, adhesions, abscess, or bleeding at necropsy. Leak test was negative in all animals. In the blinded arm, both small intestinal lacerations could not be identified by the blinded endoscopist. Necropsy revealed open small bowel lacerations. Small intestinal injuries are difficult to localize with currently available flexible endoscopes and accessories. Endoscopic clips, however, may be adequate for closure of small bowel lacerations if the site of injury is known.
Robot 2015 : Second Iberian Robotics Conference : Advances in Robotics
Moreira, António; Lima, Pedro; Montano, Luis; Muñoz-Martinez, Victor
2016-01-01
This book contains a selection of papers accepted for presentation and discussion at ROBOT 2015: Second Iberian Robotics Conference, held in Lisbon, Portugal, November 19th-21th, 2015. ROBOT 2015 is part of a series of conferences that are a joint organization of SPR – “Sociedade Portuguesa de Robótica/ Portuguese Society for Robotics”, SEIDROB – Sociedad Española para la Investigación y Desarrollo de la Robótica/ Spanish Society for Research and Development in Robotics and CEA-GTRob – Grupo Temático de Robótica/ Robotics Thematic Group. The conference organization had also the collaboration of several universities and research institutes, including: University of Minho, University of Porto, University of Lisbon, Polytechnic Institute of Porto, University of Aveiro, University of Zaragoza, University of Malaga, LIACC, INESC-TEC and LARSyS. Robot 2015 was focussed on the Robotics scientific and technological activities in the Iberian Peninsula, although open to research and delegates from other...
Mitral repair and the robot: a revolutionary tool or marketing ploy?
Ghoneim, Aly; Bouhout, Ismail; Makhdom, Fahd; Chu, Michael W A
2018-03-01
In this review, we discuss the current evidence supporting each minimally invasive mitral repair approach and their associated controversies. Current evidence demonstrates that minimally invasive mitral repair techniques yield similar mitral repair results to conventional sternotomy with the benefits of shorter hospital stay, quicker recovery, better cosmesis and improved patient satisfaction. Despite this, broad adoption of minimally invasive mitral repair is still not achieved. Two main approaches of minimally invasive mitral repair exist: endoscopic mini-thoracotomy and robotic-assisted approaches. Both minimally invasive approaches share many commonalities; however, most centres are strongly polarized to one approach over another creating controversy and debate about the most effective minimally invasive approach.
International Nuclear Information System (INIS)
Kim, Jungkwun; Allen, Mark G; Yoon, Yong-Kyu
2016-01-01
This paper presents a computer-numerical-controlled ultraviolet light-emitting diode (CNC UV-LED) lithography scheme for three-dimensional (3D) microfabrication. The CNC lithography scheme utilizes sequential multi-angled UV light exposures along with a synchronized switchable UV light source to create arbitrary 3D light traces, which are transferred into the photosensitive resist. The system comprises a switchable, movable UV-LED array as a light source, a motorized tilt-rotational sample holder, and a computer-control unit. System operation is such that the tilt-rotational sample holder moves in a pre-programmed routine, and the UV-LED is illuminated only at desired positions of the sample holder during the desired time period, enabling the formation of complex 3D microstructures. This facilitates easy fabrication of complex 3D structures, which otherwise would have required multiple manual exposure steps as in the previous multidirectional 3D UV lithography approach. Since it is batch processed, processing time is far less than that of the 3D printing approach at the expense of some reduction in the degree of achievable 3D structure complexity. In order to produce uniform light intensity from the arrayed LED light source, the UV-LED array stage has been kept rotating during exposure. UV-LED 3D fabrication capability was demonstrated through a plurality of complex structures such as V-shaped micropillars, micropanels, a micro-‘hi’ structure, a micro-‘cat’s claw,’ a micro-‘horn,’ a micro-‘calla lily,’ a micro-‘cowboy’s hat,’ and a micro-‘table napkin’ array. (paper)
Towards automated visual flexible endoscope navigation.
van der Stap, Nanda; van der Heijden, Ferdinand; Broeders, Ivo A M J
2013-10-01
The design of flexible endoscopes has not changed significantly in the past 50 years. A trend is observed towards a wider application of flexible endoscopes with an increasing role in complex intraluminal therapeutic procedures. The nonintuitive and nonergonomical steering mechanism now forms a barrier in the extension of flexible endoscope applications. Automating the navigation of endoscopes could be a solution for this problem. This paper summarizes the current state of the art in image-based navigation algorithms. The objectives are to find the most promising navigation system(s) to date and to indicate fields for further research. A systematic literature search was performed using three general search terms in two medical-technological literature databases. Papers were included according to the inclusion criteria. A total of 135 papers were analyzed. Ultimately, 26 were included. Navigation often is based on visual information, which means steering the endoscope using the images that the endoscope produces. Two main techniques are described: lumen centralization and visual odometry. Although the research results are promising, no successful, commercially available automated flexible endoscopy system exists to date. Automated systems that employ conventional flexible endoscopes show the most promising prospects in terms of cost and applicability. To produce such a system, the research focus should lie on finding low-cost mechatronics and technologically robust steering algorithms. Additional functionality and increased efficiency can be obtained through software development. The first priority is to find real-time, robust steering algorithms. These algorithms need to handle bubbles, motion blur, and other image artifacts without disrupting the steering process.
Cultural Robotics: The Culture of Robotics and Robotics in Culture
Hooman Samani; Elham Saadatian; Natalie Pang; Doros Polydorou; Owen Noel Newton Fernando; Ryohei Nakatsu; Jeffrey Tzu Kwan Valino Koh
2013-01-01
In this paper, we have investigated the concept of “Cultural Robotics” with regard to the evolution of social into cultural robots in the 21st Century. By defining the concept of culture, the potential development of a culture between humans and robots is explored. Based on the cultural values of the robotics developers, and the learning ability of current robots, cultural attributes in this regard are in the process of being formed, which would define the new concept of cultural robotics. Ac...
3D Printed Wearable Sensors with Liquid Metals for the Pose Detection of Snakelike Soft Robots.
Zhou, Luyu; Gao, Qing; Zhan, Jun-Fu; Xie, Chao-Qi; Fu, Jianzhong; He, Yong
2018-06-18
Liquid metal-based flexible sensors, which utilize advanced liquid conductive material to serve as sensitive element, is emerging as a promising solution to measure large deformations. Nowadays, one of the biggest challenges for precise control of soft robots is the detection of their real time positions. Existing fabrication methods are unable to fabricate flexible sensors that match the shape of soft robots. In this report, we firstly described a novel 3D printed multi-function inductance flexible and stretchable sensor with liquid metals (LMs), which is capable of measuring both axial tension and curvature. This sensor is fabricated with a developed coaxial liquid metal 3D printer by co-printing of silicone rubber and LMs. Due to the solenoid shape, this sensor can be easily installed on snakelike soft robots and can accurately distinguish different degrees of tensile and bending deformation. We determined the structural parameters of the sensor and proved its excellent stability and reliability. As a demonstration, we used this sensor to measure the curvature of a finger and feedback the position of endoscope, a typical snakelike structure. Because of its bending deformation form consistent with the actual working status of the soft robot and unique shape, this sensor has better practical application prospects in the pose detection.
Robot Actors, Robot Dramaturgies
DEFF Research Database (Denmark)
Jochum, Elizabeth
This paper considers the use of tele-operated robots in live performance. Robots and performance have long been linked, from the working androids and automata staged in popular exhibitions during the nineteenth century and the robots featured at Cybernetic Serendipity (1968) and the World Expo...
Kato, Shin; Kuwatani, Masaki; Sugiura, Ryo; Sano, Itsuki; Kawakubo, Kazumichi; Ono, Kota; Sakamoto, Naoya
2017-08-11
The effect of endoscopic sphincterotomy prior to endoscopic biliary stenting to prevent post-endoscopic retrograde cholangiopancreatography pancreatitis remains to be fully elucidated. The aim of this study is to prospectively evaluate the non-inferiority of non-endoscopic sphincterotomy prior to stenting for naïve major duodenal papilla compared with endoscopic sphincterotomy prior to stenting in patients with biliary stricture. We designed a multicentre randomised controlled trial, for which we will recruit 370 patients with biliary stricture requiring endoscopic biliary stenting from 26 high-volume institutions in Japan. Patients will be randomly allocated to the endoscopic sphincterotomy group or the non-endoscopic sphincterotomy group. The main outcome measure is the incidence of pancreatitis within 2 days of initial transpapillary biliary drainage. Data will be analysed on completion of the study. We will calculate the 95% confidence intervals (CIs) of the incidence of pancreatitis in each group and analyse weather the difference in both groups with 95% CIs is within the non-inferiority margin (6%) using the Wald method. This study has been approved by the institutional review board of Hokkaido University Hospital (IRB: 016-0181). Results will be submitted for presentation at an international medical conference and published in a peer-reviewed journal. The University Hospital Medical Information Network ID: UMIN000025727 Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Study for wireless power transmission of nuclear robot system
International Nuclear Information System (INIS)
Kim, Jongseog
2013-01-01
Gasoline engine or electric motor is generally used for driving power of working. Gasoline tank is uncomfortable to carry. Battery capacity does not sustain long time working. Frequent moving back of robot to power charger or refueling tank is inconvenient. Long power cable connection occur winding problem if there are complex structures in walking way. We need some solution for continuous supply of robot energy at the free moving condition of robot. 'Wireless power transmission' is one of the solutions. Some experiment result to transmit wireless power to moving robot is described herein. To find possible wireless power transmission method for nuclear robot, wireless power transmission tests were performed. As result of these tests, it was confirmed that wireless power transmission by using dipole and mat type magnetic induction were possible. As result of flying robot experiment, it was realized that development of light weight core for receiver and wave reflection device for high directional transmitter are necessary for practical use of the dipole type wireless power transmission. Small size core and high directional transmitter will be next target. Mat type wireless power transmission is regarded as useful for robot power charging station in the inside containment
Empowerment As Replacement for the Three Laws of Robotics
Directory of Open Access Journals (Sweden)
Christoph Salge
2017-06-01
Full Text Available The greater ubiquity of robots creates a need for generic guidelines for robot behavior. We focus less on how a robot can technically achieve a predefined goal and more on what a robot should do in the first place. Particularly, we are interested in the question how a heuristic should look like, which motivates the robot’s behavior in interaction with human agents. We make a concrete, operational proposal as to how the information-theoretic concept of empowerment can be used as a generic heuristic to quantify concepts, such as self-preservation, protection of the human partner, and responding to human actions. While elsewhere we studied involved single-agent scenarios in detail, here, we present proof-of-principle scenarios demonstrating how empowerment interpreted in light of these perspectives allows one to specify core concepts with a similar aim as Asimov’s Three Laws of Robotics in an operational way. Importantly, this route does not depend on having to establish an explicit verbalized understanding of human language and conventions in the robots. Also, it incorporates the ability to take into account a rich variety of different situations and types of robotic embodiment.
Study for wireless power transmission of nuclear robot system
Energy Technology Data Exchange (ETDEWEB)
Kim, Jongseog [Central Research Institute of Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of)
2013-05-15
Gasoline engine or electric motor is generally used for driving power of working. Gasoline tank is uncomfortable to carry. Battery capacity does not sustain long time working. Frequent moving back of robot to power charger or refueling tank is inconvenient. Long power cable connection occur winding problem if there are complex structures in walking way. We need some solution for continuous supply of robot energy at the free moving condition of robot. 'Wireless power transmission' is one of the solutions. Some experiment result to transmit wireless power to moving robot is described herein. To find possible wireless power transmission method for nuclear robot, wireless power transmission tests were performed. As result of these tests, it was confirmed that wireless power transmission by using dipole and mat type magnetic induction were possible. As result of flying robot experiment, it was realized that development of light weight core for receiver and wave reflection device for high directional transmitter are necessary for practical use of the dipole type wireless power transmission. Small size core and high directional transmitter will be next target. Mat type wireless power transmission is regarded as useful for robot power charging station in the inside containment.
Dynamic Modelling and Adaptive Traction Control for Mobile Robots
Directory of Open Access Journals (Sweden)
A. Albagul
2004-09-01
Full Text Available Mobile robots have received a great deal of research in recent years. A significant amount of research has been published in many aspects related to mobile robots. Most of the research is devoted to design and develop some control techniques for robot motion and path planning. A large number of researchers have used kinematic models to develop motion control strategy for mobile robots. Their argument and assumption that these models are valid if the robot has low speed, low acceleration and light load. However, dynamic modelling of mobile robots is very important as they are designed to travel at higher speed and perform heavy duty work. This paper presents and discusses a new approach to develop a dynamic model and control strategy for wheeled mobile robot which I modelled as a rigid body that roles on two wheels and a castor. The motion control strategy consists of two levels. The first level is dealing with the dynamic of the system and denoted as ‘Low’ level controller. The second level is developed to take care of path planning and trajectory generation.
New techniques in gastrointestinal endoscopic surgery
Directory of Open Access Journals (Sweden)
Rafael Antonio Luengas Tello
2012-09-01
Full Text Available Gastrointestinal endoscopic surgery has been making great progress since the seventies in the management paradigms of conditions such as gastrointestinal bleeding, polyp resection and diagnostic and therapeutic management of the biliary tract. The current challenge is the development of techniques that allow endoscopic treatment of emerging diseases such as cancer, morbid obesity, gastro-esophageal reflux and achalasia. This article reports on new techniques and expectations for the future in the endoscopic management of these diseases.
2013-02-11
... Activities: Holders or Containers Which Enter the United States Duty Free AGENCY: U.S. Customs and Border... or Containers which enter the United States Duty Free. This is a proposed extension of an information..., or other technological techniques or other forms of information. Title: Holders or Containers which...
32 CFR 767.9 - Content of permit holder's final report.
2010-07-01
... RULES APPLICATION GUIDELINES FOR ARCHEOLOGICAL RESEARCH PERMITS ON SHIP AND AIRCRAFT WRECKS UNDER THE.... The permit holder's final report shall include the following: (a) A site history and a contextual...
Directory of Open Access Journals (Sweden)
Seongjun Kim
2015-11-01
Full Text Available In endoscopic submucosal dissection (ESD, the narrow gastrointestinal space can cause difficulty in surgical interventions. Tissue ablation apparatuses with high-power CO2 lasers or Nd:YAG lasers have been developed to facilitate endoscopic surgical procedures. We studied the interaction of 808-nm laser light with a porcine stomach tissue, with the aim of developing a therapeutic medical device that can remove lesions at the gastrointestinal wall by irradiating a near-infrared laser light incorporated in an endoscopic system. The perforation depths at the porcine fillet and the stomach tissues linearly increased in the range of 2–8 mm in proportion to the laser energy density of 63.7–382 kJ/cm2. Despite the distinct structural and compositional difference, the variation of the perforation depth between the stomach and the fillet was not found at 808-nm wavelength in our measurement. We further studied the laser–tissue interaction by changing the concentration of the methyl blue solution used conventionally as a submucosal fluidic cushion (SFC in ESD procedures. The temperature of the mucosal layer increased more rapidly at higher concentration of the methyl blue solution, because of enhanced light absorption at the SFC layer. The insertion of the SFC would protect the muscle layer from thermal damage. We confirmed that more effective laser treatment should be enabled by tuning the opto-thermal properties of the SFC. This study can contribute to the optimization of the driving parameters for laser incision techniques as an alternative to conventional surgical interventions.
[Natural Orifice Transluminal Endoscopic Surgery (NOTES)].
Kim, Yong Sik; Kim, Chul Young; Chun, Hoon Jai
2008-03-01
Recently, the field of gastrointestinal endoscopy is developing rapidly. Once limited to the gastroinstestinal lumen, the endoscopic technology is now breaking the barriers and extending its boundary to peritoneal and pleural space. In 2004, Dr. Kalloo, a gastroenterologist, observed intraperitoneal organs of a pig using a conventional endoscope through the stomach wall. Since then, new endoscopic technique of intraperitoneal intervention with transluminal approach named the Natural Orifice Transluminal Endoscopic Surgery or NOTES has been introduced. NOTES reaches the target organ by inserting the endoscope through a natural orifice (e.g. mouth, anus, vagina, urethra) and entering the peritoneal lumen by means of making an incision on the luminal wall. After a series of successful experiences in animal studies, NOTES are now being tried on human subjects. There are still many obstacles to overcome, but bright future for this new technology is expected because of its proposed advantages of less pain, lower complication rate, short recovery time, and scarless access. In this review, we plan to learn about NOTES.
Socio-economic characteristics of small-holder farmers influencing ...
African Journals Online (AJOL)
Socio-economic characteristics of small-holder farmers influencing their utilisation of microcredit in the central agricultural zone of Cross River state. ... The findings revealed that about thirty – four percent (33.6%) of the crop farmers fell between 41-50 years while about 51% of the livestock farmers fell between 31-40 years.
[Tracheotomy-endoscop for dilatational percutaneous tracheotomy (TED)].
Klemm, Eckart
2006-09-01
While surgical tracheotomies are currently performed using state-of-the-art operative techniques, percutaneous dilatational tracheostomy (PDT) is in a rapidly evolving state with regard to its technology and the number of techniques available. This has resulted in a range of new complications that are difficult to quantify on a scientific basis, given the fact that more than half of the patients who are tracheotomized in intensive care units die from their underlying disease. The new Tracheotomy Endoscope (TED) is designed to help prevent serious complications in dilatational tracheotomies and facilitate their management. The endoscope has been specifically adapted to meet the require-ments of percutaneous dilatational tracheotomies. It is fully compatible with all current techniques of PDT. The method is easy to learn. The percutaneous dilatational tracheotomy with the Tracheotomy Endoscope is a seven-step procedure: Advantages of the Tracheotomy Endoscope: Injuries to the posterior tracheal wall ar impossible (tracheoesophageal fistulas, pneumothorax). Minor bleeding sites on the tracheal mucosa can be controlled with a specially curved suction-coagulation tube introudeced through the Tracheotomy Endoscope. In cases with heavy bleeding and a risk of aspiration, the rigid indwelling Tracheotomy Endoscope provides a secure route for reintubating the patient with a cuffed endotracheal tube. It also allows for rapid conversion to an open surgical procedure if necessary. All the parts are easy to clean and are autoclavable. This type of endoscopically guided PDT creates an optimal link between the specialties of intensive care medicine and otorhinolaryngology. The Tracheotomy Endoscope (TED) increases the standard of safety in PDT.
A new holder and surface MRI coil for the examination of the newborn infant hip
Energy Technology Data Exchange (ETDEWEB)
Krasny, R. (Dept. of Diagnostic Radiology, Univ. of Technology, Aachen (Germany)); Casser, H.R. (Dept. of Orthopedics, Univ. of Technology, Aachen (Germany)); Requardt, H. (Siemens AG, Erlangen (Germany)); Botschek, A. (Dept. of Diagnostic Radiology, Univ. of Technology, Aachen (Germany))
1993-11-01
A special holder was developed for examination of the infant hip joint using MRI. This holder allows the infant hip joint to be examined both in a neutral position and in various defined functional positions. A special integrated surface coil, also developed for this purpose, provides the high spatial resolution required for assessment of the fine joint structures. Thirty infants were examined and the new device has proved useful in advanced hip dysplasia, therapy-resistant subluxation and luxation, and for operative therapy planning (reconstruction of the acetabular roof, redirectional osteotomies). Interpretation errors due to misprojection can be eliminated to a large extent since the holder allows standardized and reproducible positioning. (orig.)
Chromaticity based smoke removal in endoscopic images
Tchaka, Kevin; Pawar, Vijay M.; Stoyanov, Danail
2017-02-01
In minimally invasive surgery, image quality is a critical pre-requisite to ensure a surgeons ability to perform a procedure. In endoscopic procedures, image quality can deteriorate for a number of reasons such as fogging due to the temperature gradient after intra-corporeal insertion, lack of focus and due to smoke generated when using electro-cautery to dissect tissues without bleeding. In this paper we investigate the use of vision processing techniques to remove surgical smoke and improve the clarity of the image. We model the image formation process by introducing a haze medium to account for the degradation of visibility. For simplicity and computational efficiency we use an adapted dark-channel prior method combined with histogram equalization to remove smoke artifacts to recover the radiance image and enhance the contrast and brightness of the final result. Our initial results on images from robotic assisted procedures are promising and show that the proposed approach may be used to enhance image quality during surgery without additional suction devices. In addition, the processing pipeline may be used as an important part of a robust surgical vision pipeline that can continue working in the presence of smoke.
Evaluation of teleoperated surgical robots in an enclosed undersea environment.
Doarn, Charles R; Anvari, Mehran; Low, Thomas; Broderick, Timothy J
2009-05-01
The ability to support surgical care in an extreme environment is a significant issue for both military medicine and space medicine. Telemanipulation systems, those that can be remotely operated from a distant site, have been used extensively by the National Aeronautics and Space Administration (NASA) for a number of years. These systems, often called telerobots, have successfully been applied to surgical interventions. A further extension is to operate these robotic systems over data communication networks where robotic slave and master are separated by a great distance. NASA utilizes the National Oceanographic and Atmospheric Administration (NOAA) Aquarius underwater habitat as an analog environment for research and technology evaluation missions, known as NASA Extreme Environment Mission Operations (NEEMO). Three NEEMO missions have provided an opportunity to evaluate teleoperated surgical robotics by astronauts and surgeons. Three robotic systems were deployed to the habitat for evaluation during NEEMO 7, 9, and 12. These systems were linked via a telecommunications link to various sites for remote manipulation. Researchers in the habitat conducted a variety of tests to evaluate performance and applicability in extreme environments. Over three different NEEMO missions, components of the Automated Endoscopic System for Optimal Positioning (AESOP), the M7 Surgical System, and the RAVEN were deployed and evaluated. A number of factors were evaluated, including communication latency and semiautonomous functions. The M7 was modified to permit a remote surgeon the ability to insert a needle into simulated tissue with ultrasound guidance, resulting in the world's first semi-autonomous supervisory-controlled medical task. The deployment and operation of teleoperated surgical systems and semi-autonomous, supervisory-controlled tasks were successfully conducted.
Gastroesophageal reflux disease. Scintigraphic, endoscopic and histologic considerations
Energy Technology Data Exchange (ETDEWEB)
Kault, B.; Halvorsen, T.; Petersen, H.; Grette, K.; Myrvold, H.E.
1986-01-01
Radionucleotide scintigraphy and esophagoscopy with biopsy were carried out in 101 patients with symptoms strongly suggestive of gastroesophageal reflux (GER) disease. GER was visualized by scintigraphy in 86.1% of the patients. Endoscopic and histologic esophagitis were found in 68.1% and 58.4% of the patients, respectively, whereas both examinations taken together showed evidence of esophagitis in 82%. Histologic evidence of esophagitis was found in nearly all patients with severe endoscopic changes, and in 43.7% of the patients with no endoscopic abnormality. Scintigraphic reflux was demonstrated more frequently in the patients with severe endoscopic esophagitis (97.5%) than in those with no or only mild endoscopic changes (78.6%). Scintigraphic reflux was found in 91.5% and 78.5% of the patients with and without histologic evidence of esophagitis. 15 of the 18 patients (83.3%) without endoscopic and histologic abnormalities in the esophagus had scintigraphic evidence of reflux. The present study strongly supports the clinical significance of scintigraphy in GER disease and confirms that esophageal biopsy specimens increase the sensitivity of endoscopic evaluation. 31 refs.
Non-formal Therapy and Learning Potentials Through Human Gesture Synchronized to Robotic Gesture
DEFF Research Database (Denmark)
Brooks, Tony
2006-01-01
The aim of this paper is to explore how children with severe disabilities could use a robotic light system for joyful and interactive play. Children with severe disabilities have limited possibilities for joyful experiences and interactive play. The objective of the paper was to implement a robot...
Measuring worst-case errors in a robot workcell
International Nuclear Information System (INIS)
Simon, R.W.; Brost, R.C.; Kholwadwala, D.K.
1997-10-01
Errors in model parameters, sensing, and control are inevitably present in real robot systems. These errors must be considered in order to automatically plan robust solutions to many manipulation tasks. Lozano-Perez, Mason, and Taylor proposed a formal method for synthesizing robust actions in the presence of uncertainty; this method has been extended by several subsequent researchers. All of these results presume the existence of worst-case error bounds that describe the maximum possible deviation between the robot's model of the world and reality. This paper examines the problem of measuring these error bounds for a real robot workcell. These measurements are difficult, because of the desire to completely contain all possible deviations while avoiding bounds that are overly conservative. The authors present a detailed description of a series of experiments that characterize and quantify the possible errors in visual sensing and motion control for a robot workcell equipped with standard industrial robot hardware. In addition to providing a means for measuring these specific errors, these experiments shed light on the general problem of measuring worst-case errors
International Nuclear Information System (INIS)
Mesquita, C.H. de; Hamada, M.M.
1987-01-01
Rectangular plates of plastic scintillators are developed and their effect as light converter evaluated, when used as film-holder in conventional photography dosemeters. In this dosemeter, the radiation that not interacts in the photographic film can be detected by light photons generation in the plastic scintillators, sensitizing the film. (C.G.C.) [pt
Is Ethics of Robotics about Robots? Philosophy of Robotics Beyond Realism and Individualilsm.
Coeckelbergh, Mark
2011-01-01
If we are doing ethics of robotics, what exactly is the object of our inquiry? This paper challenges 'individualist' robot ontology and 'individualist' social philosophy of robots. It is argued that ethics of robotics should not study and evaluate robotics exclusively in terms of individual
International Nuclear Information System (INIS)
Peng Yinghong; Chang Qunfeng; Li Dayong; Zeng Xiaoqin
2007-01-01
AZ31 magnesium alloy sheet with good shape and formability is fabricated by warm cross rolling. Uniaxial tensile tests are conducted using a Gleeble 3500 thermal - mechanical simulator, and the mechanical properties of AZ31 magnesium alloy sheet are analyzed. A warm deep drawing process of square part is also simulated by the finite element method. The influences of blank holder force on the formability are numerically investigated. A double-action hydraulic press that can realize adjustable blank holder forces is developed and its working principle and control system are introduced. Some warm deep drawing experiments of square parts of AZ31 magnesium alloy sheet are also performed. Different variation schemes of the blank holder force with the stroke of the punch are tested, and the experiment results are compared. Results show that the suitable blank holder force variation scheme is a ladder curve with the punch stroke. Adopting the variable blank holder force technique can improve 13.2% of the drawing depth of square parts of AZ31 magnesium alloy sheet
Robot-assisted urologic surgery in 2010 - Advancements and future outlook
Directory of Open Access Journals (Sweden)
Paurush Babbar
2011-01-01
Full Text Available Robotic surgery is a cutting edge and minimally invasive procedure, which has generated a great deal of excitement in the urologic community. While there has been much advancement in this emerging technology, it is safe to say that robotic urologic surgery holds tremendous potential for progress in the near future. Hence, it is paramount that urologists stay up-to-date regarding new developments in the realm of robotics with respect to novel applications, limitations and opportunities for incorporation into their practice. Robot-assisted surgery provides an enhanced 3D view, increased magnification of the surgical field, better manual dexterity, relatively bloodless field, elimination of surgeon′s tremor, reduction in a surgeon′s fatigue and mitigation of scattered light. All these factors translate into greater precision of surgical dissection, which is imperative in providing better intraoperative and postoperative outcomes. Pioneering work assessing the feasibility of robotic surgery in urology began in the early 2000′s with robot-assisted radical prostatectomy and has since expanded to procedures such as robot-assisted radical cystectomy, robot-assisted partial nephrectomy, robot-assisted nephroureterectomy and robot-assisted pyeloplasty. A MEDLINE search was used to identify recent articles (within the last two years and publications of specific importance, which highlighted the recent developments and future direction of robotics. This review will use the aforementioned urologic surgeries as vehicles to evaluate the current status and future role of robotics in the advancement of the field of urology.
[PACS-based endoscope image acquisition workstation].
Liu, J B; Zhuang, T G
2001-01-01
A practical PACS-based Endoscope Image Acquisition Workstation is here introduced. By a Multimedia Video Card, the endoscope video is digitized and captured dynamically or statically into computer. This workstation realizes a variety of functions such as the endoscope video's acquisition and display, as well as the editing, processing, managing, storage, printing, communication of related information. Together with other medical image workstation, it can make up the image sources of PACS for hospitals. In addition, it can also act as an independent endoscopy diagnostic system.
Brand, Judith, Ed.
2002-01-01
This issue of Exploratorium Magazine focuses on the topic robotics. It explains how to make a vibrating robotic bug and features articles on robots. Contents include: (1) "Where Robot Mice and Robot Men Run Round in Robot Towns" (Ray Bradbury); (2) "Robots at Work" (Jake Widman); (3) "Make a Vibrating Robotic Bug" (Modesto Tamez); (4) "The Robot…
Endoscopic treatment of vesicoureteral reflux in pediatric patients
Directory of Open Access Journals (Sweden)
Jong Wook Kim
2013-04-01
Full Text Available Endoscopic treatment is a minimally invasive treatment for managing patients with vesicoureteral reflux (VUR. Although several bulking agents have been used for endoscopic treatment, dextranomer/hyaluronic acid is the only bulking agent currently approved by the U.S. Food and Drug Administration for treating VUR. Endoscopic treatment of VUR has gained great popularity owing to several obvious benefits, including short operative time, short hospital stay, minimal invasiveness, high efficacy, low complication rate, and reduced cost. Initially, the success rates of endoscopic treatment have been lower than that of open antireflux surgery. However, because injection techniques have been developed, a recent study showed higher success rates of endoscopic treatment than open surgery in the treatment of patients with intermediate- and high-grade VUR. Despite the controversy surrounding its effectiveness, endoscopic treatment is considered a valuable treatment option and viable alternative to long-term antibiotic prophylaxis.
Directory of Open Access Journals (Sweden)
Katsumasa Iwai
2018-04-01
Full Text Available A method for fabricating robust and thin hollow-core optical fibers that carry mid-infrared light is proposed for use in endoscopic laser applications. The fiber is made of stainless steel tubing, eliminating the risk of scattering small glass fragments inside the body if the fiber breaks. To reduce the inner surface roughness of the tubing, a polymer base layer is formed prior to depositing silver and optical-polymer layers that confine light inside the hollow core. The surface roughness is greatly decreased by re-coating thin polymer base layers. Because of this smooth base layer surface, a uniform optical-polymer film can be formed around the core. As a result, clear interference peaks are observed in both the visible and mid-infrared regions. Transmission losses were also low for the carbon dioxide laser used for medical treatments as well as the visible laser diode used for an aiming beam. Measurements of bending losses for these lasers demonstrate the feasibility of the designed fiber for endoscopic applications.
Endoscopic versus surgical drainage treatment of calcific chronic pancreatitis.
Jiang, Li; Ning, Deng; Cheng, Qi; Chen, Xiao-Ping
2018-04-21
Endoscopic therapy and surgery are both conventional treatments to remove pancreatic duct stones that developed during the natural course of chronic pancreatitis. However, few studies comparing the effect and safety between surgery drainage and endoscopic drainage (plus Extracorporeal Shock Wave Lithotripsy, ESWL).The aim of this study was to compare the benefits between endoscopic and surgical drainage of the pancreatic duct for patients with calcified chronic pancreatitis. A total of 86 patients were classified into endoscopic/ESWL (n = 40) or surgical (n = 46) treatment groups. The medical records of these patients were retrospectively analyzed. Pain recurrence and hospital stays were similar between the endoscopic/ESWL treatment and surgery group. However, endoscopic/ESWL treatment yielded significantly lower medical expense and less complications compared with the surgical treatment. In selective patients, endoscopic/ESWL treatment could achieve comparable efficacy to the surgical treatment. With lower medical expense and less complications, endoscopic/ESWL treatment would be much preferred to be the initial treatment of choice for patients with calcified chronic pancreatitis. Copyright © 2018 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.
Asymptomatic Esophageal Varices Should Be Endoscopically Treated
Directory of Open Access Journals (Sweden)
Nib Soehendra
1998-01-01
Full Text Available Endoscopic treatment has generally been accepted in the management of bleeding esophageal varices. Both the control of acute variceal bleeding and elective variceal eradication to prevent recurrent bleeding can be achieved via endoscopic methods. In contrast to acute and elective treatment, the role of endoscopic therapy in asymptomatic patients who have never had variceal bleeding remains controversial because of the rather disappointing results obtained from prophylactic sclerotherapy. Most published randomized controlled trials showed that prophylactic sclerotherapy had no effect on survival. In some studies, neither survival rate nor bleeding risk was improved. In this article, the author champions the view that asymptomatic esophageal varices should be endoscopically treated.
Influence of endodontic instrument-holder on sterilization efficacy. A pilot in-vitro study.
Directory of Open Access Journals (Sweden)
Angelo Carrizo
2013-08-01
Full Text Available Infection control is crucial in dentistry and various methods have been designed to assure its efficacy. However, little information exists regarding the influence it could have the instrument-holder of endodontic files. The aim of this research was to determine the influence of three instruments-holders on sterilization efficacy of endodontic files. Methods: A pilot in-vitro study. 60 endodontic files were contaminated by biomechanical preparation of extracted molars with periapical abscess, then processed according to the standard washing method. The endodontic files were divided into 3 groups (n=20 and assigned to 3 instrument-holders: Metallic box (MB, surgical gauze (SG and synthetic sponge (SS. Then, the files were packaged and sterilized by autoclaving (134°C/45min. Microbiological culture was performed in thioglycolate solution for each endodontic file (37ºC/5days. Results: The overall sterilization efficacy was 91.7%, 80% for MB, 100% for SS, and 95% for SG, with no statistically significant differences (p=0.06 between the groups. Conclusions: The lack of differences in the efficacy of sterilization may be due to the reduced sample; therefore, a full-size study is necessary to confirm this outcomes. The results of this study discourage the use of the MB as instrument-holder until a full-size study can confirm this data.
Robot Teleoperation and Perception Assistance with a Virtual Holographic Display
Goddard, Charles O.
2012-01-01
Teleoperation of robots in space from Earth has historically been dfficult. Speed of light delays make direct joystick-type control infeasible, so it is desirable to command a robot in a very high-level fashion. However, in order to provide such an interface, knowledge of what objects are in the robot's environment and how they can be interacted with is required. In addition, many tasks that would be desirable to perform are highly spatial, requiring some form of six degree of freedom input. These two issues can be combined, allowing the user to assist the robot's perception by identifying the locations of objects in the scene. The zSpace system, a virtual holographic environment, provides a virtual three-dimensional space superimposed over real space and a stylus tracking position and rotation inside of it. Using this system, a possible interface for this sort of robot control is proposed.
Endoscopic Management of an Intramural Sinus Leak After Per- Oral Endoscopic Myotomy
Al Taii, Haider; Confer, Bradley; Gabbard, Scott; Kroh, Matthew; Jang, Sunguk; Rodriguez, John; Parsi, Mansour A.; Vargo, John J.; Ponsky, Jeffrey
2016-01-01
Per-oral endoscopic myotomy (POEM) was developed less than a decade ago for the treatment of achalasia. Its minimally invasive approach and the favorable short-term outcome have led to rapid adoption of the technique throughout the world. As with any new technique, there will be adverse events, and it is important that effective treatments for these adverse events be discussed. We present a case of successful endoscopic management of an intramural sinus leak after a POEM procedure using tandem fully covered esophageal stents. PMID:27921057
Glove holder system for containment shell
International Nuclear Information System (INIS)
Picco, B.
1993-01-01
A glove holder for an isolated chamber used e.g. for handling toxic or radioactive materials and made with at least one access port in its wall, equipped with a ring to which the glove is attached, has a sleeve which connects the ring to the glove proper and protects the forarm. The sleeve is in at least two sections, a first corrugated section and a second, supple section which is able to fold inside the first section. ADVANTAGE - Reduced costs and quantity of waste produced by enabling glove proper only to be replaced. (author)
International Nuclear Information System (INIS)
Scheide, A.W.
1983-01-01
This article reviews some of the technical areas and history associated with robotics, provides information relative to the formation of a Robotics Industry Committee within the Industry Applications Society (IAS), and describes how all activities relating to robotics will be coordinated within the IEEE. Industrial robots are being used for material handling, processes such as coating and arc welding, and some mechanical and electronics assembly. An industrial robot is defined as a programmable, multifunctional manipulator designed to move material, parts, tools, or specialized devices through variable programmed motions for a variety of tasks. The initial focus of the Robotics Industry Committee will be on the application of robotics systems to the various industries that are represented within the IAS
Endoscopic versus open bursectomy of lateral malleolar bursitis.
Choi, Jae Hyuck; Lee, Kyung Tai; Lee, Young Koo; Kim, Dong Hyun; Kim, Jeong Ryoul; Chung, Woo Chull; Cha, Seung Do
2012-06-01
Compare the result of endoscopic versus open bursectomy in lateral malleolar bursitis. Prospective evaluation of 21 patients (22 ankles) undergoing either open or endoscopic excision of lateral malleolar bursitis. The median age was 64 (38-79) years old. The median postoperative follow-up was 15 (12-18) months. Those patients undergoing endoscopic excision showed a higher satisfaction rate (excellent 9, good 2) than open excision (excellent 4, good 3, fair 1). The wounds also healed earlier in the endoscopic group although the operation time was slightly longer. One patient in the endoscopic group had recurrence of symptoms but complications in the open group included one patient with skin necrosis, one patient with wound dehiscence, and two patients of with superficial peroneal nerve injury. Endoscopic resection of the lateral malleolar bursitis is a promising technique and shows favorable results compared to the open resection. Therapeutic studies-Investigating the result of treatment, Level II.
A Panoramic Wireless Endoscope System Design for the Application of Minimally Invasive Surgery
Directory of Open Access Journals (Sweden)
Chun-Hsiang Peng
2014-05-01
Full Text Available Minimally Invasive Surgery (MIS is the current trend in surgery. Compared to traditional surgery, MIS can substantially decrease recovery time and expenses needed by patients after surgeries, reduce pain during surgical procedures, and is highly regarded by physicians and patients. An endoscope is widely used in the diagnosis and treatments of various medical disciplines, such as hysteroscopy, laparoscopy, and colonoscopy, and have been adopted by many branches of medicine. However, the limited image field of MIS is often the most difficult obstacles faced by surgeons and medical students, especially to less experienced physicians and difficult surgical procedures; the limited field of view of endoscopic imaging does not provide a whole picture of the surgery area, making the procedures difficult and full of uncertainty. In light of this problem, we proposed a "Panoramic Wireless Endoscope System design", hoping to provide physicians with a wide field of view of the endoscopic image. We combine images captured from two parallel-mounted endoscope lenses into a single, wide-angle image, giving physicians a wider field of view and easier access to the surgical area. In addition, we developed a wireless transmission system so the image can be transmitted to various display platforms, eliminating the needs for excessive cabling on surgical tools and enable physicians to better operate on the patient. Finally, our system allows surgical assistants a better view of the operation process, and enables other physicians and nurses to remotely observe the process. Our experiment results have shown that we can increase the image to 152% of its original size. We used the PandaBoard ES platform with an ARM9 processor and 1G of onboard RAM, and continuously implementing animal trials to verify the reliability of our system.
Ultrasound-assisted endoscopic partial plantar fascia release.
Ohuchi, Hiroshi; Ichikawa, Ken; Shinga, Kotaro; Hattori, Soichi; Yamada, Shin; Takahashi, Kazuhisa
2013-01-01
Various surgical treatment procedures for plantar fasciitis, such as open surgery, percutaneous release, and endoscopic surgery, exist. Skin trouble, nerve disturbance, infection, and persistent pain associated with prolonged recovery time are complications of open surgery. Endoscopic partial plantar fascia release offers the surgeon clear visualization of the anatomy at the surgical site. However, the primary medial portal and portal tract used for this technique have been shown to be in close proximity to the posterior tibial nerves and their branches, and there is always the risk of nerve damage by introducing the endoscope deep to the plantar fascia. By performing endoscopic partial plantar fascia release under ultrasound assistance, we could dynamically visualize the direction of the endoscope and instrument introduction, thus preventing nerve damage from inadvertent insertion deep to the fascia. Full-thickness release of the plantar fascia at the ideal position could also be confirmed under ultrasound imaging. We discuss the technique for this new procedure.
Directory of Open Access Journals (Sweden)
Sarmed S. Sami
2014-01-01
Full Text Available Early lesion detection and characterisation is vital to ensure accurate management in patients with gastrointestinal neoplasia. Endoscopic Tri-modal Imaging (ETMI technology has been shown to improve the targeted detection of early dysplastic lesions in Barrett's Oesophagus, but these results were not confirmed in non-expert hands [1]. This technology incorporates high resolution while light endoscopy (HRE, Auto Fluorescence Imaging (AFI and Narrow Band Imaging (NBI in one endoscope. The mucosa is first inspected with HRE, and then AFI is switched on to help in highlighting any suspicious areas in the mucosa [2]. These areas can be further examined by switching to NBI mode with magnification which helps to characterise mucosal patterns and identify early neoplasia [3].
Additive Manufacturing of Parts and Tooling in Robotic Systems
Energy Technology Data Exchange (ETDEWEB)
Love, Lonnie J. [ORNL; Hassen, Ahmed A. [ORNL; Chesser, Phillip C. [ORNL; Parsons, Jeremy [Mantaro Networks, Inc.
2018-04-01
ORNL worked with Transcend Robotics, LLC to explore additive manufacturing of the two-piece compression body for their ARTI mobile robot platform. Extrusion compression molding was identified as an effective means of manufacturing these parts. ORNL consulted on modifications to the housing design to accommodate the selected manufacturing process. Parts were printed using ORNL's FDM machines for testing and evaluation of the design as a precursor to molding the parts. The assembly and evaluation of the parts proved favorable and minor design changes to improve assembly and performance were identified.The goal is to develop a light weight and rugged two-part robotic enclosure for an unmanned ground vehicle UGV) that will be used in search and rescue applications. The FDM parts fabricated by ORNL allowed Transcend Robotics to assemble a prototype robot and verify that the new parts will meet the performance requirements. ORNL fabricated enclosure parts out of ABS and Nylon 12 materials such that the design could be tested prior to fabricating tooling for compression molding of Nylon 6 with carbon fiber fill. The robot was performance tested and compared with the previous manufacturing techniques and found to have superior performance.
Visual Recognition and Its Application to Robot Arm Control
Directory of Open Access Journals (Sweden)
Jih-Gau Juang
2015-10-01
Full Text Available This paper presents an application of optical word recognition and fuzzy control to a smartphone automatic test system. The system consists of a robot arm and two webcams. After the words from the control panel that represent commands are recognized by the robot system, the robot arm performs the corresponding actions to test the smartphone. One of the webcams is utilized to capture commands on the screen of the control panel, the other to recognize the words on the screen of the tested smartphone. The method of image processing is based on the Red-Green-Blue (RGB and Hue-Saturation-Luminance (HSL color spaces to reduce the influence of light. Fuzzy theory is used in the robot arm’s position control. The Optical Character Recognition (OCR technique is applied to the word recognition, and the recognition results are then checked by a dictionary process to increase the recognition accuracy. The camera which is used to recognize the tested smartphone also provides object coordinates to the fuzzy controller, then the robot arm moves to the desired positions and presses the desired buttons. The proposed control scheme allows the robot arm to perform different assigned test functions successfully.
A robotic platform for laser welding of corneal tissue
Rossi, Francesca; Micheletti, Filippo; Magni, Giada; Pini, Roberto; Menabuoni, Luca; Leoni, Fabio; Magnani, Bernardo
2017-07-01
Robotic surgery is a reality in several surgical fields, such as in gastrointestinal surgery. In ophthalmic surgery the required high spatial precision is limiting the application of robotic system, and even if several attempts have been designed in the last 10 years, only some application in retinal surgery were tested in animal models. The combination of photonics and robotics can really open new frontiers in minimally invasive surgery, improving the precision, reducing tremor, amplifying scale of motion, and automating the procedure. In this manuscript we present the preliminary results in developing a vision guided robotic platform for laser-assisted anterior eye surgery. The robotic console is composed by a robotic arm equipped with an "end effector" designed to deliver laser light to the anterior corneal surface. The main intended application is for laser welding of corneal tissue in laser assisted penetrating keratoplasty and endothelial keratoplasty. The console is equipped with an integrated vision system. The experiment originates from a clear medical demand in order to improve the efficacy of different surgical procedures: when the prototype will be optimized, other surgical areas will be included in its application, such as neurosurgery, urology and spinal surgery.
Contrast-enhanced endoscopic ultrasonography
DEFF Research Database (Denmark)
Reddy, Nischita K; Ioncica, Ana Maria; Saftoiu, Adrian
2011-01-01
Contrast agents are increasingly being used to characterize the vasculature in an organ of interest, to better delineate benign from malignant pathology and to aid in staging and directing therapeutic procedures. We review the mechanisms of action of first, second and third generation contrast...... agents and their use in various endoscopic procedures in the gastrointestinal tract. Various applications of contrast-enhanced endoscopic ultrasonography include differentiating benign from malignant mediastinal lymphadenopathy, assessment of depth of invasion of esophageal, gastric and gall bladder...
Is endoscopic nodular gastritis associated with premalignant lesions?
Niknam, R; Manafi, A; Maghbool, M; Kouhpayeh, A; Mahmoudi, L
2015-06-01
Nodularity on the gastric mucosa is occasionally seen in general practice. There is no consensus about the association of nodular gastritis and histological premalignant lesions. This study is designed to investigate the prevalence of histological premalignant lesions in dyspeptic patients with endoscopic nodular gastritis. Consecutive patients with endoscopic nodular gastritis were compared with an age- and sex-matched control group. Endoscopic nodular gastritis was defined as a miliary nodular appearance of the gastric mucosa on endoscopy. Biopsy samples of stomach tissue were examined for the presence of atrophic gastritis, intestinal metaplasia, and dysplasia. The presence of Helicobacter pylori infection was determined by histology. From 5366 evaluated patients, a total of 273 patients with endoscopic nodular gastritis and 1103 participants as control group were enrolled. H. pylori infection was detected in 87.5% of the patients with endoscopic nodular gastritis, whereas 73.8% of the control group were positive for H. pylori (p gastritis were significantly higher than in the control group. Prevalence of atrophic gastritis and complete intestinal metaplasia were also more frequent in patients with endoscopic nodular gastritis than in the control group. Dysplasia, incomplete intestinal metaplasia and H. pylori infection are significantly more frequent in patients with endoscopic nodular gastritis. Although further studies are needed before a clear conclusion can be reached, we suggest that endoscopic nodular gastritis might serve as a premalignant lesion and could be biopsied in all patients for the possibility of histological premalignancy, in addition to H. pylori infection.
Gesture-Based Robot Control with Variable Autonomy from the JPL Biosleeve
Wolf, Michael T.; Assad, Christopher; Vernacchia, Matthew T.; Fromm, Joshua; Jethani, Henna L.
2013-01-01
This paper presents a new gesture-based human interface for natural robot control. Detailed activity of the user's hand and arm is acquired via a novel device, called the BioSleeve, which packages dry-contact surface electromyography (EMG) and an inertial measurement unit (IMU) into a sleeve worn on the forearm. The BioSleeve's accompanying algorithms can reliably decode as many as sixteen discrete hand gestures and estimate the continuous orientation of the forearm. These gestures and positions are mapped to robot commands that, to varying degrees, integrate with the robot's perception of its environment and its ability to complete tasks autonomously. This flexible approach enables, for example, supervisory point-to-goal commands, virtual joystick for guarded teleoperation, and high degree of freedom mimicked manipulation, all from a single device. The BioSleeve is meant for portable field use; unlike other gesture recognition systems, use of the BioSleeve for robot control is invariant to lighting conditions, occlusions, and the human-robot spatial relationship and does not encumber the user's hands. The BioSleeve control approach has been implemented on three robot types, and we present proof-of-principle demonstrations with mobile ground robots, manipulation robots, and prosthetic hands.
Towards Versatile Robots Through Open Heterogeneous Modular Robots
DEFF Research Database (Denmark)
Lyder, Andreas
arises, a new robot can be assembled rapidly from the existing modules, in contrast to conventional robots, which require a time consuming and expensive development process. In this thesis we define a modular robot to be a robot consisting of dynamically reconfigurable modules. The goal of this thesis......Robots are important tools in our everyday life. Both in industry and at the consumer level they serve the purpose of increasing our scope and extending our capabilities. Modular robots take the next step, allowing us to easily create and build various robots from a set of modules. If a problem...... is to increase the versatility and practical usability of modular robots by introducing new conceptual designs. Until now modular robots have been based on a pre-specified set of modules, and thus, their functionality is limited. We propose an open heterogeneous design concept, which allows a modular robot...
Small holder farmers coping strategies to household food insecurity ...
African Journals Online (AJOL)
This study has aimed at examining the small holder farmers' coping strategies to sustained household food insecurity and hunger in Southern Ethiopia (Sidama Zone). In order to collect the required input data, a comprehensive interview schedule was developed. The data were collected from 614 households who were ...
Small holder farmers coping strategies to household food insecurity ...
African Journals Online (AJOL)
Small holder farmers coping strategies to household food insecurity and hunger in Southern Ethiopia. ... Ethiopian Journal of Environmental Studies and Management ... The study further showed that households in the study area employ a range of coping strategies to respond to the high and sustained food insecurity and ...
International Nuclear Information System (INIS)
Çalışkan, Halil; Kurşuncu, Bilal; Kurbanoğlu, Cahit; Güven, Şevki Yılmaz
2013-01-01
Highlights: ► The material selection problem for tool holders used in hard milling was solved. ► EXPROM2, TOPSIS and VIKOR methods were used for ranking the alternative materials. ► The weighting of criteria was performed by compromised weighting method. ► The best material for the tool holder was selected as Fe–5Cr–Mo–V aircraft steel. -- Abstract: Nowadays machining of materials in their hardened state, also called hard machining, is a challenge in production of tools and molds. It has some advantages such as lower process time and lower manufacturing cost when compared to conventional machining. In machining of hard workpiece materials, however, very high stresses act on the tool holder through the cutting tool. These stresses necessitate the tool holder to have some specific properties. Especially in hard milling, the tool holder should have high stiffness and should be able to dissipate the energy generated during interrupted cutting. Material cost of the tool holder is also important since lower costs provide a competitive advantage for manufacturers. The material selection for the tool holder should be conducted considering aforementioned requirements. To tackle the difficulty of the material selection with specific properties from a large number of alternatives, multi-criteria decision-making (MCDM) methods have been used. In this paper a decision model including extended PROMETHEE II (EXPROM2) (preference ranking organization method for enrichment evaluation), TOPSIS (technique for order performance by similarity to ideal solution) and VIKOR (VIšekriterijumsko KOmpromisno Rangiranje) methods were used for the selection of the best material for the tool holder used in hard milling. The criteria weighting was performed by compromised weighting method composed of AHP (analytic hierarchy process) and Entropy methods. The candidate materials were ranked by using these methods and the results obtained by each method were compared. It was confirmed
Forming Human-Robot Teams Across Time and Space
Hambuchen, Kimberly; Burridge, Robert R.; Ambrose, Robert O.; Bluethmann, William J.; Diftler, Myron A.; Radford, Nicolaus A.
2012-01-01
NASA pushes telerobotics to distances that span the Solar System. At this scale, time of flight for communication is limited by the speed of light, inducing long time delays, narrow bandwidth and the real risk of data disruption. NASA also supports missions where humans are in direct contact with robots during extravehicular activity (EVA), giving a range of zero to hundreds of millions of miles for NASA s definition of "tele". . Another temporal variable is mission phasing. NASA missions are now being considered that combine early robotic phases with later human arrival, then transition back to robot only operations. Robots can preposition, scout, sample or construct in advance of human teammates, transition to assistant roles when the crew are present, and then become care-takers when the crew returns to Earth. This paper will describe advances in robot safety and command interaction approaches developed to form effective human-robot teams, overcoming challenges of time delay and adapting as the team transitions from robot only to robots and crew. The work is predicated on the idea that when robots are alone in space, they are still part of a human-robot team acting as surrogates for people back on Earth or in other distant locations. Software, interaction modes and control methods will be described that can operate robots in all these conditions. A novel control mode for operating robots across time delay was developed using a graphical simulation on the human side of the communication, allowing a remote supervisor to drive and command a robot in simulation with no time delay, then monitor progress of the actual robot as data returns from the round trip to and from the robot. Since the robot must be responsible for safety out to at least the round trip time period, the authors developed a multi layer safety system able to detect and protect the robot and people in its workspace. This safety system is also running when humans are in direct contact with the robot
International Nuclear Information System (INIS)
Mesquita, C.H. de; Hamada, M.M.
1987-01-01
The use of rectangular plates of plastic scintillators as film holders in conventional photographic dosemeters is reported. The efficiency of their use as light converters for increase the sensitivity of these dosemeters are studied. (M.A.C.) [pt
Compact Dexterous Robotic Hand
Lovchik, Christopher Scott (Inventor); Diftler, Myron A. (Inventor)
2001-01-01
A compact robotic hand includes a palm housing, a wrist section, and a forearm section. The palm housing supports a plurality of fingers and one or more movable palm members that cooperate with the fingers to grasp and/or release an object. Each flexible finger comprises a plurality of hingedly connected segments, including a proximal segment pivotally connected to the palm housing. The proximal finger segment includes at least one groove defining first and second cam surfaces for engagement with a cable. A plurality of lead screw assemblies each carried by the palm housing are supplied with power from a flexible shaft rotated by an actuator and output linear motion to a cable move a finger. The cable is secured within a respective groove and enables each finger to move between an opened and closed position. A decoupling assembly pivotally connected to a proximal finger segment enables a cable connected thereto to control movement of an intermediate and distal finger segment independent of movement of the proximal finger segment. The dexterous robotic hand closely resembles the function of a human hand yet is light weight and capable of grasping both heavy and light objects with a high degree of precision.
Yang, Min Jae; Kim, Jin Hong; Hwang, Jae Chul; Yoo, Byung Moo; Kim, Soon Sun; Lim, Sun Gyo; Won, Je Hwan
2017-12-01
The rendezvous approach is a salvage technique after failure of endoscopic retrograde cholangiography (ERC). In certain circumstances, percutaneous-endoscopic rendezvous (PE-RV) is preferred, and endoscopic ultrasound-guided rendezvous (EUS-RV) is difficult to perform. We aimed to evaluate PE-RV outcomes, describe the PE-RV techniques, and identify potential indications for PE-RV over EUS-RV.Retrospective analysis was conducted of a prospectively designed ERC database between January 2005 and December 2016 at a tertiary referral center including cases where PE-RV was used as a salvage procedure after ERC failure.During the study period, PE-RV was performed in 42 cases after failed therapeutic ERC; 15 had a surgically altered enteric anatomy. The technical success rate of PE-RV was 92.9% (39/42), with a therapeutic success rate of 88.1% (37/42). Potential indications for PE-RV over EUS-RV were identified in 23 cases, and either PE-RV or EUS-RV could have effectively been used in 19 cases. Endoscopic bile duct access was successfully achieved with PE-RV in 39 cases with accessible biliary orifice using one of PE-RV cannulation techniques (classic, n = 11; parallel, n = 19; and adjunctive maneuvers, n = 9).PE-RV uses a unique technology and has clinical indications that distinguish it from EUS-RV. Therefore, PE-RV can still be considered a useful salvage technique for the treatment of biliary obstruction after ERC failure.
Ebner, F H; Roser, F; Thaher, F; Schittenhelm, J; Tatagiba, M
2010-10-01
We report about endoscope-assisted surgery of epidermoid cysts in the posterior fossa focusing on the application of neuro-endoscopy and the clinical outcome in cases of recurrent epidermoid cysts. 25 consecutively operated patients with an epidermoid cyst in the posterior fossa were retrospectively analysed. Surgeries were performed both with an operating microscope (OPMI Pentero or NC 4, Zeiss Company, Oberkochen, Germany) and endoscopic equipment (4 mm rigid endoscopes with 30° and 70° optics; Karl Storz Company, Tuttlingen, Germany) under continuous intraoperative monitoring. Surgical reports and DVD-recordings were evaluated for identification of adhesion areas and surgical details. 7 (28%) of the 25 patients were recurrences of previously operated epidermoid cysts. Mean time to recurrence was 17 years (8-22 years). In 5 cases the endoscope was used as an adjunctive tool for inspection/endoscope-assisted removal of remnants. The effective time of use of the endoscope was limited to the end stage of the procedure, but was very effective. In a modern operative setting and with the necessary surgical experience recurrent epidermoid cysts may be removed with excellent clinical results. The combined use of microscope and endoscope offers relevant advantages in demanding anatomic situations. © Georg Thieme Verlag KG Stuttgart · New York.
McLaughlin, Eamon J; Cunningham, Michael J; Kazahaya, Ken; Hsing, Julianna; Kawai, Kosuke; Adil, Eelam A
2016-06-01
To evaluate the feasibility of radiofrequency surgical instrumentation for endoscopic resection of juvenile nasopharyngeal angiofibroma (JNA) and to test the hypothesis that endoscopic radiofrequency ablation-assisted (RFA) resection will have superior intraoperative and/or postoperative outcomes as compared with traditional endoscopic (TE) resection techniques. Case series with chart review. Two tertiary care pediatric hospitals. Twenty-nine pediatric patients who underwent endoscopic transnasal resection of JNA from January 2000 to December 2014. Twenty-nine patients underwent RFA (n = 13) or TE (n = 16) JNA resection over the 15-year study period. Mean patient age was not statistically different between the 2 groups (P = .41); neither was their University of Pittsburgh Medical Center classification stage (P = .79). All patients underwent preoperative embolization. Mean operative times were not statistically different (P = .29). Mean intraoperative blood loss and the need for a transfusion were also not statistically different (P = .27 and .47, respectively). Length of hospital stay was not statistically different (P = .46). Recurrence rates did not differ between groups (P = .99) over a mean follow-up period of 2.3 years. There were no significant differences between RFA and TE resection in intraoperative or postoperative outcome parameters. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.
Taking NOTES: translumenal flexible endoscopy and endoscopic surgery.
Willingham, Field F; Brugge, William R
2007-09-01
To review the current state of natural orifice surgery and examine the concerns, challenges, and opportunities presented by translumenal research. Translumenal endoscopic procedures have been the focus of extensive research. Researchers have reported natural orifice translumenal endoscopic surgery in a swine model in several areas involving the abdominal cavity. Diagnostic procedures have included endoscopic peritoneoscopy, liver biopsy, lymphadenectomy, and abdominal exploration. Several gynecologic procedures including tubal ligation, oophorectomy, and partial hysterectomy have been demonstrated using current commercial endoscopes. Gastrointestinal surgical procedures, including gastrojejunostomy, cholecystectomy, splenectomy, and distal pancreatectomy have been performed successfully via transgastric and/or transcolonic approaches. There have been no studies of natural orifice translumenal endoscopic surgery procedures published in humans. While fundamental questions about the emerging technology have not been scrutinized, limitations of the large animal model will pose a challenge to the development of large randomized trials. While natural orifice translumenal endoscopic surgery may represent a paradigm shift and may offer significant benefits to patients, rigorous testing of the techniques is lacking and current data have been drawn from case series.
Endoscopic approach to the infratemporal fossa
Directory of Open Access Journals (Sweden)
Ahmed Youssef
2014-06-01
Conclusions: Endoscopic endonasal transpterygoid approach is considered one of the most useful surgical solutions to manage selected tumors that involve the infratemporal fossa. A good understanding of the endoscopic anatomy of infratemporal fossa allows safe and complete resection of lesions arising or extending to infratemporal fossa.
Multiple cues produced by a robotic fish modulate aggressive behaviour in Siamese fighting fishes.
Romano, Donato; Benelli, Giovanni; Donati, Elisa; Remorini, Damiano; Canale, Angelo; Stefanini, Cesare
2017-07-05
The use of robotics to establish social interactions between animals and robots, represents an elegant and innovative method to investigate animal behaviour. However, robots are still underused to investigate high complex and flexible behaviours, such as aggression. Here, Betta splendens was tested as model system to shed light on the effect of a robotic fish eliciting aggression. We evaluated how multiple signal systems, including a light stimulus, affect aggressive responses in B. splendens. Furthermore, we conducted experiments to estimate if aggressive responses were triggered by the biomimetic shape of fish replica, or whether any intruder object was effective as well. Male fishes showed longer and higher aggressive displays as puzzled stimuli from the fish replica increased. When the fish replica emitted its full sequence of cues, the intensity of aggression exceeded even that produced by real fish opponents. Fish replica shape was necessary for conspecific opponent perception, evoking significant aggressive responses. Overall, this study highlights that the efficacy of an artificial opponent eliciting aggressive behaviour in fish can be boosted by exposure to multiple signals. Optimizing the cue combination delivered by the robotic fish replica may be helpful to predict escalating levels of aggression.
[Endoscopic ultrasound guided rendezvous for biliary drainage].
Knudsen, Marie Høxbro; Vilmann, Peter; Hassan, Hazem; Karstensen, John Gésdal
2015-04-27
Endoscopic retrograde cholangiography (ERCP) is currently standard treatment for biliary drainage. Endoscopic ultrasound guided rendezvous (EUS-RV) is a novel method to overcome an unsuccessful biliary drainage procedure. Under endoscopic ultrasound guidance a guidewire is passed via a needle from the stomach or duodenum to the common bile duct and from there on to the duodenum enabling ERCP. With a relatively high rate of success EUS-RV should be considered as an alternative to biliary drainage and surgical intervention.
Elimination of high titre HIV from fibreoptic endoscopes.
Hanson, P J; Gor, D; Jeffries, D J; Collins, J V
1990-06-01
Concern about contamination of fibreoptic endoscopes with human immunodeficiency virus (HIV) has generated a variety of disruptive and possibly unnecessary infection control practices in endoscopy units. Current recommendations on the cleaning and disinfection of endoscopes have been formulated without applied experimental evidence of the effective removal of HIV from endoscopes. To study the kinetics of elimination of HIV from endoscope surfaces, we artificially contaminated the suction-biopsy channels of five Olympus GIF XQ20 endoscopes with high titre HIV in serum. The air and water channels of two instruments were similarly contaminated. Contamination was measured by irrigating channels with viral culture medium and collecting 3 ml at the distal end for antigen immunoassay. Endoscopes were then cleaned manually in neutral detergent according to the manufacturer's recommendations and disinfected in 2% alkaline glutaraldehyde (Cidex, Surgikos) for two, four, and ten minutes. Contamination with HIV antigens was measured before and after cleaning and after each period of disinfection. Initial contamination comprised 4.8 x 10(4) to 3.5 x 10(6) pg HIV antigen/ml. Cleaning in detergent achieved a reduction to 165 pg/ml (99.93%) on one endoscope and to undetectable levels (100%) on four. After two minutes in alkaline glutaraldehyde all samples were negative and remained negative after the longer disinfection times. Air and water channels, where contaminated, were tested after 10 minutes' disinfection and were negative. These findings underline the importance of cleaning in removing HIV from endoscope and indicate that the use of dedicated equipment and long disinfection times are unnecessary.
Cruise and turning performance of an improved fish robot actuated by piezoceramic actuators
Nguyen, Quang Sang; Heo, Seok; Park, Hoon Cheol; Goo, Nam Seo; Byun, Doyoung
2009-03-01
The purpose of this study is improvement of a fish robot actuated by four light-weight piezocomposite actuators (LIPCAs). In the fish robot, we developed a new actuation mechanism working without any gear and thus the actuation mechanism was simple in fabrication. By using the new actuation mechanism, cross section of the fish robot became 30% smaller than that of the previous model. Performance tests of the fish robot in water were carried out to measure tail-beat angle, thrust force, swimming speed and turning radius for tail-beat frequencies from 1Hz to 5Hz. The maximum swimming speed of the fish robot was 7.7 cm/s at 3.9Hz tail-beat frequency. Turning experiment showed that swimming direction of the fish robot could be controlled with 0.41 m turning radius by controlling tail-beat angle.
International Nuclear Information System (INIS)
Morimoto, Masahiro; Nishiyama, Kinji; Nakamura, Satoaki
2010-01-01
The efficacy of endoscopic screening for esophageal cancer in patients with hypopharyngeal cancer remains controversial and its impact on prognosis has not been adequately discussed. We studied the use of endoscopic screening to detect esophageal cancer in hypopharyngeal cancer patients by analyzing the incidence, stage and prognosis. We included 64 patients with hypopharyngeal cancer who received radical radiotherapy at our institute. Chromoendoscopic esophageal examinations with Lugol dye solution were routinely performed at and after treatment for hypopharyngeal cancer. Twenty-eight esophageal cancers were detected in 28 (41%) patients (18 synchronous and 10 metachronous cancers). Of the 28 cancers, 23 were stage 0 or I cancer and 15 of these were treated with endoscopic resection. Local control was achieved in all of these 23 stage 0 or I cancers. The 5-year overall survival rates with esophageal cancer were 83% in stage 0, 47% in stage I and 0% in stage IIA-IVB. This study showed a strikingly high incidence of esophageal cancer in hypopharyngeal cancer patients. We suppose that the combination of early detection by chromoendoscopic examination and endoscopic resection for associated esophageal cancer in hypopharyngeal cancer patients improve prognosis and maintain quality of life. (author)
Limits of the endoscopic transnasal transtubercular approach.
Gellner, Verena; Tomazic, Peter V
2018-06-01
The endoscopic transnasal trans-sphenoidal transtubercular approach has become a standard alternative approach to neurosurgical transcranial routes for lesions of the anterior skull base in particular pathologies of the anterior tubercle, sphenoid plane, and midline lesions up to the interpeduncular cistern. For both the endoscopic and the transcranial approach indications must strictly be evaluated and tailored to the patients' morphology and condition. The purpose of this review was to evaluate the evidence in literature of the limitations of the endoscopic transtubercular approach. A PubMed/Medline search was conducted in January 2018 entering following keywords. Upon initial screening 7 papers were included in this review. There are several other papers describing the endoscopic transtubercular approach (ETTA). We tried to list the limitation factors according to the actual existing literature as cited. The main limiting factors are laterally extending lesions in relation to the optic canal and vascular encasement and/or unfavorable tumor tissue consistency. The ETTA is considered as a high level transnasal endoscopic extended skull base approach and requires excellent training, skills and experience.
Vettoretto, Nereo; Arezzo, Alberto; Famiglietti, Federico; Cirocchi, Roberto; Moja, Lorenzo; Morino, Mario
2018-04-11
The management of gallbladder stones (lithiasis) concomitant with bile duct stones is controversial. The more frequent approach is a two-stage procedure, with endoscopic sphincterotomy and stone removal from the bile duct followed by laparoscopic cholecystectomy. The laparoscopic-endoscopic rendezvous combines the two techniques in a single-stage operation. To compare the benefits and harms of endoscopic sphincterotomy and stone removal followed by laparoscopic cholecystectomy (the single-stage rendezvous technique) versus preoperative endoscopic sphincterotomy followed by laparoscopic cholecystectomy (two stages) in people with gallbladder and common bile duct stones. We searched The Cochrane Hepato-Biliary Group Controlled Trials Register, CENTRAL, MEDLINE Ovid, Embase Ovid, Science Citation Index Expanded Web of Science, and two trials registers (February 2017). We included randomised clinical trials that enrolled people with concomitant gallbladder and common bile duct stones, regardless of clinical status or diagnostic work-up, and compared laparoscopic-endoscopic rendezvous versus preoperative endoscopic sphincterotomy procedures in people undergoing laparoscopic cholecystectomy. We excluded other endoscopic or surgical methods of intraoperative clearance of the bile duct, e.g. non-aided intraoperative endoscopic retrograde cholangiopancreatography or laparoscopic choledocholithotomy (surgical incision of the common bile duct for removal of bile duct stones). We used standard methodological procedures recommended by Cochrane. We included five randomised clinical trials with 517 participants (257 underwent a laparoscopic-endoscopic rendezvous technique versus 260 underwent a sequential approach), which fulfilled our inclusion criteria and provided data for analysis. Trial participants were scheduled for laparoscopic cholecystectomy because of suspected cholecysto-choledocholithiasis. Male/female ratio was 0.7; age of men and women ranged from 21 years to 87
Development of automated endoscopes for dimensional micro-measurements
Hrebabetzky, Frank
2013-04-01
Increasing demands for product quality and outsourcing of production in the automobile industry lead to in creasingly tight tolerances for the components. In the area of metal-mechanics these are largely dimensional and require frequently uncertainties in the micron region. For optical instruments this means microscopical resolu tion. Dimensional measurement with uncertainties of some microns is nothing new, state of the art equipment in fact goes far below. The task becomes difficult if the measurements have to be carried out in an industrial production environment - and deep inside a bore hole. This paper describes the development of an automatic measurement system for internal dimensions of brake master cylinders, specifically the development of endoscopes, illuminations for edge detection, and integration with other sensors, actuators and controllers. The most demanding part was the endoscope development, because, surprisingly, no commercial product for microscopic view and precision measurements was found on the market. As the market for such measurement machines is very small, and as the requirements were different for each endoscope, the budget allowed only the development of prototypes, using readily available optical components. Borders between faces with different orientation of metallic structures can be difficult do detect. A satisfactory metrological performance can be achieved only with carefully shaped illumination, even if the source is a simple LED (light emitting diode). The automation was responsible for the largest part of the overall cost, coming from the desire for a high throughput of the measurement machine, even when operated by not highly qualified personnel. With the safety requirements satisfied, such a device ends up as a pretty complex equipment. Nevertheless, these aspects will be mentioned only for completeness, because standard components and methods were applied.
Endoscopic inspection of steam turbines
International Nuclear Information System (INIS)
Maliniemi, H.; Muukka, E.
1990-01-01
For over ten years, Imatran Voima Oy (IVO) has developed, complementary inspection methods for steam turbine condition monitoring, which can be applied both during operation and shutdown. One important method used periodically during outages is endoscopic inspection. The inspection is based on the method where the internal parts of the turbine is inspected through access borings with endoscope and where the magnified figures of the internal parts is seen on video screen. To improve inspection assurance, an image-processing based pattern recognition method for cracks has been developed for the endoscopic inspection of turbine blades. It is based on the deduction conditions derived from the crack shape. The computer gives an alarm of a crack detection and prints a simulated image of the crack, which is then checked manually
Endoscopic Palliation for Pancreatic Cancer
Directory of Open Access Journals (Sweden)
Mihir Bakhru
2011-04-01
Full Text Available Pancreatic cancer is devastating due to its poor prognosis. Patients require a multidisciplinary approach to guide available options, mostly palliative because of advanced disease at presentation. Palliation including relief of biliary obstruction, gastric outlet obstruction, and cancer-related pain has become the focus in patients whose cancer is determined to be unresectable. Endoscopic stenting for biliary obstruction is an option for drainage to avoid the complications including jaundice, pruritus, infection, liver dysfunction and eventually failure. Enteral stents can relieve gastric obstruction and allow patients to resume oral intake. Pain is difficult to treat in cancer patients and endoscopic procedures such as pancreatic stenting and celiac plexus neurolysis can provide relief. The objective of endoscopic palliation is to primarily address symptoms as well improve quality of life.
Energy Technology Data Exchange (ETDEWEB)
Jung, Seul
2006-02-15
This book deals with robot engineering, giving descriptions of robot's history, current tendency of robot field, work and characteristic of industrial robot, essential merit and vector, application of matrix, analysis of basic vector, expression of Denavit-Hartenberg, robot kinematics such as forward kinematics, inverse kinematics, cases of MATLAB program, and motion kinematics, robot kinetics like moment of inertia, centrifugal force and coriolis power, and Euler-Lagrangian equation course plan, SIMULINK position control of robots.
International Nuclear Information System (INIS)
Jung, Seul
2006-02-01
This book deals with robot engineering, giving descriptions of robot's history, current tendency of robot field, work and characteristic of industrial robot, essential merit and vector, application of matrix, analysis of basic vector, expression of Denavit-Hartenberg, robot kinematics such as forward kinematics, inverse kinematics, cases of MATLAB program, and motion kinematics, robot kinetics like moment of inertia, centrifugal force and coriolis power, and Euler-Lagrangian equation course plan, SIMULINK position control of robots.
Evaluation of the uncertainty associated with sample holders in NAA measurements in LAN/IPEN
Energy Technology Data Exchange (ETDEWEB)
Zahn, Guilherme S.; Ticianelli, Regina B.; Saiki, Mitiko; Genezini, Frederico A., E-mail: ticianelli@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)
2017-07-01
In IPEN's Neutron Activation Laboratory (LAN/IPEN), thin stainless steel sample holders are used for gamma spectrometry in NAA measurements. This material is very practical, but its chemical composition may be troublesome, as it presents large amounts of elements with intermediate atomic number, with attenuation factors for low-energy gamma-rays that must not be neglected. In this study, count rates obtained using different sample holders were compared. To accomplish that, an Am-241 source, with 59-keV gamma emission, was used so that low-energy gamma attenuation differences can be determined. Moreover, in order to study the energy dependence of these differences, a Ho-166m source was also used. From these results, it was possible to analyze the experimental error associated to the variations between sample holders, with the aim of introducing an addictive term to the uncertainty analysis of comparative Neutron Activation Analysis results. (author)
DEFF Research Database (Denmark)
Ainsworth, A P; Rafaelsen, S R; Wamberg, P A
2004-01-01
BACKGROUND: It is not known whether initial endoscopic ultrasonography (EUS) or magnetic resonance cholangiopancreatography (MRCP) is more cost effective than endoscopic retrograde cholangiopancreatography (ERCP). METHODS: A cost-effectiveness analysis of EUS, MRCP and ERCP was performed on 163...
2010-04-01
..., form of proxy or other communication to such holders, including to the extent known or reasonably... provided for under applicable state law identifying the proposal or other corporate action that will be the subject of the security holder's solicitation or communication and attesting that: (i) The security holder...
Field robot event, Wageningen, 5-6 June 2003
Straten, van G.
2004-01-01
A brief report is given of the field robot contest held in Wageningen, 5-6 June 2003. The experience of the student competitors sheds light on a number of issues that need to be addressed before autonomous vehicles will become a reality
Report on the Installation and Preparedness of a Protochips Fusion in-situ Heating Holder for TEM
Energy Technology Data Exchange (ETDEWEB)
Edmondson, Philip D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
2017-03-01
This brief report documents the procurement and installation of a Protochips Fusion (formerly Aduro) high-temperature, high stability transmission electron microscopy (TEM) specimen holder that allows for the high spatial resolution characterization of material specimens at high temperature in situ of an electron microscope. This specimen holder was specifically procured for use with The FEI Talos F200X Scanning/Transmission Electron Microscope (STEM) in Oak Ridge National Laboratory’s (ORNL’s) Low Activation Materials Development and Analysis (LAMDA) Laboratory. The Protochips Fusion holder will enable high-resolution structural and chemical analysis of irradiated materials at high temperature, becoming a unique capability worldwide, and would encourage high-quality in situ experiments to be conducted on irradiated materials.
Calibration of Robot Reference Frames for Enhanced Robot Positioning Accuracy
Cheng, Frank Shaopeng
2008-01-01
This chapter discussed the importance and methods of conducting robot workcell calibration for enhancing the accuracy of the robot TCP positions in industrial robot applications. It shows that the robot frame transformations define the robot geometric parameters such as joint position variables, link dimensions, and joint offsets in an industrial robot system. The D-H representation allows the robot designer to model the robot motion geometry with the four standard D-H parameters. The robot k...
Measurements in Concentrated Sun using a Remote Controlled Robot
Directory of Open Access Journals (Sweden)
Dan Floroian
2013-04-01
Full Text Available Nowdays, using the concentrated sunlight is a big issue because the amount of energy is very high and the light is concentrated in a very small area. The main problem in this situation is the heating, and in order to make safe measurements a remote controlled robot is needed. After that, a remote controlled robot will assume the duty of protect the measured sample and to expose it for a precise time to the concentrated sun in order to reduce heating of the sample. For easy operating, and for automatize the process, all the duties, starting with initial conditions, continuing with triggering the measurements, and conditioning the signals and finalizing with data saving must be assured by the robot.
Endoscopic management of bile leaks after laparoscopic ...
African Journals Online (AJOL)
Endoscopic management of bile leaks after laparoscopic cholecystectomy. ... endoscopic management at a median of 12 days (range 2 - 104 days) after surgery. Presenting features included intra-abdominal collections with pain in 58 cases ...
Endoscopic Ultrasonography in the Diagnosis of Gastric Subepithelial Lesions
Directory of Open Access Journals (Sweden)
Eun Jeong Gong
2016-09-01
Full Text Available Subepithelial lesions occasionally found in the stomach of patients undergoing endoscopy may be either benign lesions or tumors with malignant potential. They may also appear due to extrinsic compression. Discrimination of gastric subepithelial lesions begins with meticulous endoscopic examination for size, shape, color, mobility, consistency, and appearance of the overlying mucosa. Accurate diagnosis can be achieved with endoscopic ultrasonography, which provides useful information on the exact size, layer-of-origin, and characteristic morphologic features to support a definitive diagnosis. Endoscopic ultrasonography also aids in the prediction of malignant potential, especially in gastrointestinal stromal tumors. Features of subepithelial lesions identified on endoscopic ultrasonography can be used to determine whether further diagnostic procedures such as endoscopic resection, fine needle aspiration, or core biopsy are required. Endoscopic ultrasonography is a valuable tool for diagnosis and clinical decision making during follow-up of gastric subepithelial lesions.
Endoscopic Management of Tumor Bleeding from Inoperable Gastric Cancer
Kim, Young-Il
2015-01-01
Tumor bleeding is not a rare complication in patients with inoperable gastric cancer. Endoscopy has important roles in the diagnosis and primary treatment of tumor bleeding, similar to its roles in other non-variceal upper gastrointestinal bleeding cases. Although limited studies have been performed, endoscopic therapy has been highly successful in achieving initial hemostasis. One or a combination of endoscopic therapy modalities, such as injection therapy, mechanical therapy, or ablative therapy, can be used for hemostasis in patients with endoscopic stigmata of recent hemorrhage. However, rebleeding after successful hemostasis with endoscopic therapy frequently occurs. Endoscopic therapy may be a treatment option for successfully controlling this rebleeding. Transarterial embolization or palliative surgery should be considered when endoscopic therapy fails. For primary and secondary prevention of tumor bleeding, proton pump inhibitors can be prescribed, although their effectiveness to prevent bleeding remains to be investigated. PMID:25844339
International Nuclear Information System (INIS)
Sweeney, Reinhart; Bale, Reto; Vogele, Michael; Nevinny-Stickel, Meinhart; Bluhm, Anja; Auer, Thomas; Hessenberger, Gerhart; Lukas, Peter
1998-01-01
Purpose: To compare accuracy, clinical feasibility, and subjective patient impression between a noninvasive head holder (Vogele Bale Hohner [VBH]; Wellhoefer Dosimetry, Schwarzenbruck, Germany) developed at the University of Innsbruck and the thermoplastic mask fixation system for use in fractionated external radiotherapy. We present a case report of an actual patient fixated in the VBH head holder during radiation therapy. Materials and Methods: The VBH head holder consists of an individualized vacuum dental cast connected to a head plate via two hydraulic arms allowing noninvasive, reproducible head fixation of even uncooperative patients. Accuracy was tested and compared with that of the thermoplastic mask using the Phillips EasyGuide navigation system on five volunteers. Specific external registration points served as landmarks and their positions were compared after each repositioning. System and operator inaccuracy were also taken into account. The times taken for production and repositioning of the respective fixation devices were compared, and subjective impressions were noted. Results: Mean VBH head holder repositioning accuracy was 1.02 mm while that of the thermoplastic mask was 3.05 mm. 69% of mask repositionings showed a deviation > 2 mm and 41% > 3 mm (as opposed to 8% and 1% respectively for the VBH head holder) Those points located farthest away from the respective plane of fixation showed the largest deviations. Both production and repositioning times were similar between the systems; depending upon the patient, the VBH head holder was generally better tolerated than the mask system. Conclusion: Due to its significantly better repositioning accuracy compared to that of the thermoplastic mask, the VBH head holder is especially suited for external radiation requiring precise repositioning due to critical tissues in immediate surrounding of the area to be irradiated
Fischer, Martin
2012-12-01
The article sheds light on psychological and work science aspects of the design and utilization of service robots. An initial presentation of the characteristics of man-robot interaction is followed by a discussion of the principles of the division of functions between human beings and robots in service area work systems. The following aspects are to be considered: (1) the organisation of societal work (such as the different employment and professional profiles of service employees), (2) the work tasks to be performed by humans and robots (such as handling, monitoring or decision-making tasks), (3) the possibilities and the limitations of realizing such tasks by means of information technology (depending, for example, on the motoric capabilities, perception and cognition of the robot). Consideration of these three design perspectives gives rise to criteria of usability. Current debate focuses on the (work science) principles of man-machine communication, though in future these should be supplemented with robot-specific criteria such as "motoric capabilities" or "relationship quality." The article concludes by advocating the convergence and combination of work science criteria with ideas drawn from participative design approaches in the development and utilization of service robots.
Antibiotic prophylaxis for patients undergoing elective endoscopic ...
African Journals Online (AJOL)
Antibiotic prophylaxis for patients undergoing elective endoscopic retrograde cholangiopancreatography. M Brand, D Bisoz. Abstract. Background. Antibiotic prophylaxis for endoscopic retrograde cholangiopancreatography (ERCP) is controversial. We set out to assess the current antibiotic prescribing practice among ...
Research on scholarships holders who studied abroad and returned to Serbia
Directory of Open Access Journals (Sweden)
Nena A. Vasojevic
2017-10-01
Full Text Available Knowledge has become the most valuable resource of the new era and the resource of the future. The intention of this study is to improve knowledge about the problem of migration of educated people from Serbia from the perspective of scholarship holders who, after being abroad, returned to their country. The aim of this research is to show the profile of the scholarship holders of post-academic and post-graduate students, who studied abroad and then returned to Serbia. Their motives for departure and return, as well as their perception of integration into the work environment in Serbia and utilization of their knowledge is presented. Methods: For the purpose of this research a questionnaire was constructed which was distributed online. Collected data were analysed using statistical tools. Results: This research has shown that the primary motive for education abroad is the desire for personal development. It has also been shown that an important factor for the return of students from abroad is their expectation of comparative advantage in the labour market and their belief of getting a desired job. Apart from this, it is shown that the scholarship holders only partially used the acquired knowledge and thus, do not have enough influence in the development of their organizations.Conclusion: The main research contribution is reflected in the improvement of the knowledge about the motivation of scholars to return from developed countries and highlighted problems which scholarship holders have after returning.Implications and research limitation: the results obtained can be generalised to countries that are passing or have recently moved a transition, and are similar in cultural characteristics. The present contains certain limitations that must be taken into account while interpreting final results. The most significant constraint is the sample size, but the obtained results, especially the motives of the scientific experts for a return to the country
Endoscopic Instruments and Electrosurgical Unit for Colonoscopic Polypectomy
Park, Hong Jun
2016-01-01
Colorectal polypectomy is an effective method for prevention of colorectal cancer. Many endoscopic instruments have been used for colorectal polypectomy, such as snares, forceps, endoscopic clips, a Coagrasper, retrieval net, injector, and electrosurgery generator unit (ESU). Understanding the characteristics of endoscopic instruments and their proper use according to morphology and size of the colorectal polyp will enable endoscopists to perform effective polypectomy. I reviewed the characte...
Light Duty Utility Arm computer software configuration management plan
International Nuclear Information System (INIS)
Philipp, B.L.
1998-01-01
This plan describes the configuration management for the Light Duty Utility Arm robotic manipulation arm control software. It identifies the requirement, associated documents, and the software control methodology. The Light Duty Utility Ann (LDUA) System is a multi-axis robotic manipulator arm and deployment vehicle, used to perform surveillance and characterization operations in support of remediation of defense nuclear wastes currently stored in the Hanford Underground Storage Tanks (USTs) through the available 30.5 cm (12 in.) risers. This plan describes the configuration management of the LDUA software
Bruemmer, David J [Idaho Falls, ID; Few, Douglas A [Idaho Falls, ID
2010-09-21
The present invention provides methods, computer readable media, and apparatuses for a generic robot architecture providing a framework that is easily portable to a variety of robot platforms and is configured to provide hardware abstractions, abstractions for generic robot attributes, environment abstractions, and robot behaviors. The generic robot architecture includes a hardware abstraction level and a robot abstraction level. The hardware abstraction level is configured for developing hardware abstractions that define, monitor, and control hardware modules available on a robot platform. The robot abstraction level is configured for defining robot attributes and provides a software framework for building robot behaviors from the robot attributes. Each of the robot attributes includes hardware information from at least one hardware abstraction. In addition, each robot attribute is configured to substantially isolate the robot behaviors from the at least one hardware abstraction.
Molecular Robots Obeying Asimov's Three Laws of Robotics.
Kaminka, Gal A; Spokoini-Stern, Rachel; Amir, Yaniv; Agmon, Noa; Bachelet, Ido
2017-01-01
Asimov's three laws of robotics, which were shaped in the literary work of Isaac Asimov (1920-1992) and others, define a crucial code of behavior that fictional autonomous robots must obey as a condition for their integration into human society. While, general implementation of these laws in robots is widely considered impractical, limited-scope versions have been demonstrated and have proven useful in spurring scientific debate on aspects of safety and autonomy in robots and intelligent systems. In this work, we use Asimov's laws to examine these notions in molecular robots fabricated from DNA origami. We successfully programmed these robots to obey, by means of interactions between individual robots in a large population, an appropriately scoped variant of Asimov's laws, and even emulate the key scenario from Asimov's story "Runaround," in which a fictional robot gets into trouble despite adhering to the laws. Our findings show that abstract, complex notions can be encoded and implemented at the molecular scale, when we understand robots on this scale on the basis of their interactions.
Post-endoscopic biliary sphincterotomy bleeding: an interventional radiology approach.
LENUS (Irish Health Repository)
Dunne, Ruth
2013-12-01
Endoscopic sphincterotomy is an integral component of endoscopic retrograde cholangiopancreatography. Post-sphincterotomy hemorrhage is a recognized complication. First line treatment involves a variety of endoscopic techniques performed at the time of sphincterotomy. If these are not successful, transcatheter arterial embolization or open surgical vessel ligation are therapeutic considerations.
Colias: An Autonomous Micro Robot for Swarm Robotic Applications
Directory of Open Access Journals (Sweden)
Farshad Arvin
2014-07-01
Full Text Available Robotic swarms that take inspiration from nature are becoming a fascinating topic for multi-robot researchers. The aim is to control a large number of simple robots in order to solve common complex tasks. Due to the hardware complexities and cost of robot platforms, current research in swarm robotics is mostly performed by simulation software. The simulation of large numbers of these robots in robotic swarm applications is extremely complex and often inaccurate due to the poor modelling of external conditions. In this paper, we present the design of a low-cost, open-platform, autonomous micro-robot (Colias for robotic swarm applications. Colias employs a circular platform with a diameter of 4 cm. It has a maximum speed of 35 cm/s which enables it to be used in swarm scenarios very quickly over large arenas. Long-range infrared modules with an adjustable output power allow the robot to communicate with its direct neighbours at a range of 0.5 cm to 2 m. Colias has been designed as a complete platform with supporting software development tools for robotics education and research. It has been tested in both individual and swarm scenarios, and the observed results demonstrate its feasibility for use as a micro-sized mobile robot and as a low-cost platform for robot swarm applications.
Endoscopic electrosurgical papillotomy and manometry in biliary tract disease.
Geenen, J E; Hogan, W J; Shaffer, R D; Stewart, E T; Dodds, W J; Arndorfer, R C
1977-05-09
Endoscopic papillotomy was performed in 13 patients after cholecystectomy for retained or recurrent common bile duct calculi (11 patients) and a clinical picture suggesting papillary stenosis (two patients). Following endoscopic papillotomy, ten of the 11 patients spontaneously passed common bile duct (CBD) stones verified on repeated endoscopic retrograde cholangiopancreatography (ERCP) study. One patient failed to pass a large CBD calculus; one patient experienced cholangitis three months after in inadequate papillotomy and required operative intervention. Endoscopic papillotomy substantially decreased the pressure gradient existing between the CBD and the duodenum in all five patients studied with ERCP manometry. Endoscopic papillotomy is a relatively safe and effective procedure for postcholecystectomy patients with retained or recurrent CBD stones. The majority of CBD stones will pass spontaneously if the papillotomy is adequate.
Light-driven micro-robotics for contemporary biophotonics
DEFF Research Database (Denmark)
Villangca, Mark Jayson
is a documentation on the design and fabrication process, sample preparation, experimental procedure and demonstration of the capabilities of the micro-robots and our outlook on their potential use in biophotonics. As we have used tools as extension of our hands in the early study of biology, we envision these micro......In the early days of biology, dissection has been the staple for studying the functions of the body and its component organs. The invention of the microscope has paved the way the study of cells, bacteria and other microorganisms. The ability to move such microorganisms or send stimulus...... in a controlled manner can push our understanding of the dynamics at cellular level. In this regard, the discovery of light’s radiation forces becomes important in the field of biology. The field of optical manipulation has evolved from the simple demonstration of radiation forces to more sophisticated trapping...
International Nuclear Information System (INIS)
Pisch, Julianna; Belsley, Scott J.; Ashton, Robert; Wang Lin; Woode, Rudolph; Connery, Cliff
2004-01-01
Purpose: To evaluate the feasibility of using the da Vinci robotic system for radioactive seed placement in the wedge resection margin of pigs' lungs. Methods and materials: Video-assisted thoracoscopic wedge resection was performed in the upper and lower lobes in pigs. Dummy 125 I seeds embedded in absorbable sutures were sewn into the resection margin with the aid of the da Vinci robotic system without complications. In the 'loop technique,' the seeds were placed in a cylindrical pattern; in the 'longitudinal,' they were above and lateral to the resection margin. Orthogonal radiographs were taken in the operating room. For dose calculation, Variseed 66.7 (Build 11312) software was used. Results: With looping seed placement, in the coronal view, the dose at 1 cm from the source was 97.0 Gy; in the lateral view it was 107.3 Gy. For longitudinal seed placement, the numbers were 89.5 Gy and 70.0 Gy, respectively. Conclusion: Robotic technology allows direct placement of radioactive seeds into the resection margin by endoscopic surgery. It overcomes the technical difficulties of manipulating in the narrow chest cavity. With the advent of robotic technology, new options in the treatment of lung cancer, as well as other malignant tumors, will become available
Directory of Open Access Journals (Sweden)
Harith M. Alkhateeb
2015-01-01
Conclusions: (1 Following endoscopic retrograde cholangiopancreatography, a patient’s complaints should not be ignored. (2 A massive biloma can occur due to such procedures. (3 Conservative treatment with minimal invasive technique can prove to be effective.
A sample holder for in-house X-ray powder diffraction studies of protein powders
DEFF Research Database (Denmark)
Frankær, Christian Grundahl; Harris, Pernille; Ståhl, Kenny
2011-01-01
A sample holder for handling samples of protein for in-house X-ray powder diffraction (XRPD) analysis has been made and tested on lysozyme. The use of an integrated pinhole reduced the background, and good signal-to-noise ratios were obtained from only 7 l of sample, corresponding to approximatel...... 2-3 mg of dry protein. The sample holder is further adaptable to X-ray absorption spectroscopy (XAS) measurements. Both XRPD and XAS at the Zn K-edge were tested with hexameric Zn insulin....
International Nuclear Information System (INIS)
Lad, N; Adebayo, D; Aroussi, A
2011-01-01
Particle image velocimetry (PIV) is a successful flow mapping technique which can optically quantify large portions of a flow regime. This enables the method to be completely non-intrusive. The ability to be non-intrusive to any flow has allowed PIV to be used in a large range of industrial sectors for many applications. However, a fundamental disadvantage of the conventional PIV technique is that it cannot easily be used with flows which have no or limited optical access. Flows which have limited optical access for PIV measurement have been addressed using endoscopic PIV techniques. This system uses two separate probes which relay a light sheet and imaging optics to a planar position within the desired flow regime. This system is effective in medical and engineering applications. The present study has been involved in the development of a new endoscopic PIV system which integrates the illumination and imaging optics into one rigid probe. This paper focuses on the validation of the images taken from the novel single stem endoscopic PIV system. The probe is used within atomized spray flow and is compared with conventional PIV measurement and also pitot-static data. The endoscopic PIV system provides images which create localized velocity maps that are comparable with the global measurement of the conventional PIV system. The velocity information for both systems clearly show similar results for the spray characterization and are also validated using the pitot-static data
Duodenal diverticular bleeding: an endoscopic challenge
Directory of Open Access Journals (Sweden)
Eduardo Valdivielso-Cortázar
Full Text Available Duodenal diverticula are an uncommon cause of upper gastrointestinal bleeding. Until recently, it was primarily managed with surgery, but advances in the field of endoscopy have made management increasingly less invasive. We report a case of duodenal diverticular bleeding that was endoscopically managed, and review the literature about the various endoscopic therapies thus far described.
Light‐driven Nano‐robotics - Invited Plenary Presentation, IEEE NANO 2016
DEFF Research Database (Denmark)
Glückstad, Jesper
) and pioneering their use in so-called lightdriven nano-robotics. Hence, the aim of our latest R&D is to combine advanced topology optimisation, 3D printing of functionalized materials and light manipulation to demonstrate a structure-mediated micro-tonano coupling paradigm for controlled operation of robotic...... tools overcoming the diffraction limit while still being optically visible and manoeuvrable. 2PP-fabrication can already today create intricate nano-features merged onto larger microstructures that, in turn, are steerable by dynamic light beams. Applying multiple independently controllable laser beam...... traps on these structures will enable real-time light-driven nanorobotics with six-degrees-of-freedom. This sets the stage for new discoveries using calibrated steering of optimally shaped and functionalized nano-tools at the subcellular level and in full 3D - not available in the scientifi c world...
International Nuclear Information System (INIS)
Jeon, Yon Ho
1991-07-01
This book gives descriptions of micro robot about conception of robots and micro robot, match rules of conference of micro robots, search methods of mazes, and future and prospect of robots. It also explains making and design of 8 beat robot like making technique, software, sensor board circuit, and stepping motor catalog, speedy 3, Mr. Black and Mr. White, making and design of 16 beat robot, such as micro robot artist, Jerry 2 and magic art of shortening distances algorithm of robot simulation.
What do we learn about development from baby robots?
Oudeyer, Pierre-Yves
2017-01-01
Understanding infant development is one of the great scientific challenges of contemporary science. In addressing this challenge, robots have proven useful as they allow experimenters to model the developing brain and body and understand the processes by which new patterns emerge in sensorimotor, cognitive, and social domains. Robotics also complements traditional experimental methods in psychology and neuroscience, where only a few variables can be studied at the same time. Moreover, work with robots has enabled researchers to systematically explore the role of the body in shaping the development of skill. All told, this work has shed new light on development as a complex dynamical system. WIREs Cogn Sci 2017, 8:e1395. doi: 10.1002/wcs.1395 For further resources related to this article, please visit the WIREs website. © 2016 Wiley Periodicals, Inc.
[Current Status of Endoscopic Resection of Early Gastric Cancer in Korea].
Jung, Hwoon Yong
2017-09-25
Endoscopic resection (Endoscopic mucosal resection [EMR] and endoscopic submucosal dissection [ESD]) is already established as a first-line treatment modality for selected early gastric cancer (EGC). In Korea, the number of endoscopic resection of EGC was explosively increased because of a National Cancer Screening Program and development of devices and techniques. There were many reports on the short-term and long-term outcomes after endoscopic resection in patients with EGC. Long-term outcome in terms of recurrence and death is excellent in both absolute and selected expanded criteria. Furthermore, endoscopic resection might be positioned as primary treatment modality replacing surgical gastrectomy. To obtain these results, selection of patients, perfect en bloc procedure, thorough pathological examination of resected specimen, accurate interpretation of whole process of endoscopic resection, and rational strategy for follow-up is necessary.
Endoscopic Management of Peri-Pancreatic Fluid Collections.
Yip, Hon Chi; Teoh, Anthony Yuen Bun
2017-09-15
In the past decade, there has been a progressive paradigm shift in the management of peri-pancreatic fluid collections after acute pancreatitis. Refinements in the definitions of fluid collections from the updated Atlanta classification have enabled better communication amongst physicians in an effort to formulate optimal treatments. Endoscopic ultrasound (EUS)-guided drainage of pancreatic pseudocysts has emerged as the procedure of choice over surgical cystogastrostomy. The approach provides similar success rates with low complications and better quality of life compared with surgery. However, an endoscopic "step up" approach in the management of pancreatic walled-off necrosis has also been advocated. Both endoscopic and percutaneous drainage routes may be used depending on the anatomical location of the collections. New-generation large diameter EUS-specific stent systems have also recently been described. The device allows precise and effective drainage of the collections and permits endoscopic necrosectomy through the stents.
Modelling of industrial robot in LabView Robotics
Banas, W.; Cwikła, G.; Foit, K.; Gwiazda, A.; Monica, Z.; Sekala, A.
2017-08-01
Currently can find many models of industrial systems including robots. These models differ from each other not only by the accuracy representation parameters, but the representation range. For example, CAD models describe the geometry of the robot and some even designate a mass parameters as mass, center of gravity, moment of inertia, etc. These models are used in the design of robotic lines and sockets. Also systems for off-line programming use these models and many of them can be exported to CAD. It is important to note that models for off-line programming describe not only the geometry but contain the information necessary to create a program for the robot. Exports from CAD to off-line programming system requires additional information. These models are used for static determination of reachability points, and testing collision. It’s enough to generate a program for the robot, and even check the interaction of elements of the production line, or robotic cell. Mathematical models allow robots to study the properties of kinematic and dynamic of robot movement. In these models the geometry is not so important, so are used only selected parameters such as the length of the robot arm, the center of gravity, moment of inertia. These parameters are introduced into the equations of motion of the robot and motion parameters are determined.
Modeling returns to education and labour market outcomes of doctoral degree holders in Bulgaria
Simeonova-Ganeva, Ralitsa; Panayotova, Nataliya; Ganev, Kaloyan
2013-01-01
In this study we present the theoretical framework of the so called Mincerian equations used for modelling returns to education. Then, we construct a conceptual framework which allows us to answer the question “What happens to doctoral degree holders in the labour market?”. We analyse data for about 45,000 PhD graduates in Bulgaria from the NSI survey Career development of PhD degree holders run in 2007, 2009, and 2010. An attempt is made to measure pay gaps in terms of gender and major of st...
DEFF Research Database (Denmark)
Ngo, Trung Dung
This thesis studies aspects of self-sufficient energy (energy autonomy) for truly autonomous robots and towards sociable robots. Over sixty years of history of robotics through three developmental ages containing single robot, multi-robot systems, and social (sociable) robots, the main objective...... of roboticists mostly focuses on how to make a robotic system function autonomously and further, socially. However, such approaches mostly emphasize behavioural autonomy, rather than energy autonomy which is the key factor for not only any living machine, but for life on the earth. Consequently, self......-sufficient energy is one of the challenges for not only single robot or multi-robot systems, but also social and sociable robots. This thesis is to deal with energy autonomy for multi-robot systems through energy sharing (trophallaxis) in which each robot is equipped with two capabilities: self-refueling energy...
Biomass feeds vegetarian robot; Biomassa voedt vegetarische robot
Energy Technology Data Exchange (ETDEWEB)
Van den Brandt, M. [Office for Science and Technology, Embassy of the Kingdom of the Netherlands, Washington (United States)
2009-09-15
This brief article addresses the EATR robot (Energetically Autonomous Tactical Robot) that was developed by Cyclone Power and uses biomass as primary source of energy for propulsion. [Dutch] Een kort artikel over de door Cyclone Power ontwikkelde EATR-robot (Energetically Autonomous Tactical Robot) die voor de voortdrijving biomassa gebruikt als primaire energiebron.
Clinical evaluation of complete solo surgery with the "ViKY®" robotic laparoscope manipulator.
Takahashi, Masahiro; Takahashi, Masanori; Nishinari, Naoto; Matsuya, Hideki; Tosha, Tsutomu; Minagawa, Yukihiro; Shimooki, Osamu; Abe, Tadashi
2017-02-01
Advancement in both surgical technique and medical equipment has enabled solo surgery. ViKY ® Endoscope Positioning System (ViKY ® ) is a robotic system that remotely controls an endoscope and provides direct vision control to the surgeon. Here, we report our experience with ViKY ® -assisted solo surgery. We retrospectively examined 25 cases of solo surgery TAPP with ViKY ® . ViKY ® was setup by the surgeon alone, and the setup duration was determined as the time at which the side rail was positioned and that when the endoscope was installed. For assessing the control unit, the number of false movements was counted. We compared the operative results between ViKY ® -assisted solo surgery TAPP and the conventional method with an assistant. The average time to set up ViKY ® was 7.9 min. The average number of commands for ViKY ® during surgery was 98.3, and the average number of errors and no response of control unit was 7.9. The mean duration of surgery was 136 min for the ViKY ® group, including the setup time, and 117 min for the conventional method. No case required an assistant during the operation. There was also no difference between the two groups with regard to postoperative complications and the rate of recurrence. ViKY ® proved reliable in recognizing orders with very few failures, and the operations were performed safely and were comparable to the conventional operations with assistants. Solo surgery with ViKY ® was beneficial in this clinical evaluation.
DEFF Research Database (Denmark)
Christoffersen, Anja; Grindsted Nielsen, Sally; Jochum, Elizabeth Ann
Robots are increasingly used in health care settings, e.g., as homecare assistants and personal companions. One challenge for personal robots in the home is acceptance. We describe an innovative approach to influencing the acceptance of care robots using theatrical performance. Live performance...... is a useful testbed for developing and evaluating what makes robots expressive; it is also a useful platform for designing robot behaviors and dialogue that result in believable characters. Therefore theatre is a valuable testbed for studying human-robot interaction (HRI). We investigate how audiences...... perceive social robots interacting with humans in a future care scenario through a scripted performance. We discuss our methods and initial findings, and outline future work....
Rossiter, Jonathan; Iida, Fumiya; Cianchetti, Matteo; Margheri, Laura
2017-01-01
This book offers a comprehensive, timely snapshot of current research, technologies and applications of soft robotics. The different chapters, written by international experts across multiple fields of soft robotics, cover innovative systems and technologies for soft robot legged locomotion, soft robot manipulation, underwater soft robotics, biomimetic soft robotic platforms, plant-inspired soft robots, flying soft robots, soft robotics in surgery, as well as methods for their modeling and control. Based on the results of the second edition of the Soft Robotics Week, held on April 25 – 30, 2016, in Livorno, Italy, the book reports on the major research lines and novel technologies presented and discussed during the event.
Towards Versatile Robots Through Open Heterogeneous Modular Robots
Lyder, Andreas
2010-01-01
Robots are important tools in our everyday life. Both in industry and at the consumer level they serve the purpose of increasing our scope and extending our capabilities. Modular robots take the next step, allowing us to easily create and build various robots from a set of modules. If a problem arises, a new robot can be assembled rapidly from the existing modules, in contrast to conventional robots, which require a time consuming and expensive development process. In this thesis we define a ...
CSIR Research Space (South Africa)
Mtshali, M
2010-01-01
Full Text Available In the development of mobile robotic systems, a robotic architecture plays a crucial role in interconnecting all the sub-systems and controlling the system. The design of robotic architectures for mobile autonomous robots is a challenging...
Endoscopic management of peripancreatic fluid collections.
Goyal, Jatinder; Ramesh, Jayapal
2015-07-01
Peripancreatic fluid collections are a well-known complication of pancreatitis and can vary from fluid-filled collections to entirely necrotic collections. Although most of the fluid-filled pseudocysts tend to resolve spontaneously with conservative management, intervention is necessary in symptomatic patients. Open surgery has been the traditional treatment modality of choice though endoscopic, laparoscopic and transcutaneous techniques offer alternative drainage approaches. During the last decade, improvement in endoscopic ultrasound technology has enabled real-time access and drainage of fluid collections that were previously not amenable to blind transmural drainage. This has initiated a trend towards use of this modality for treatment of pseudocysts. In this review, we have summarised the existing evidence for endoscopic drainage of peripancreatic fluid collections from published studies.
Nasal encephalocele: endoscopic excision with anesthetic consideration.
Abdel-Aziz, Mosaad; El-Bosraty, Hussam; Qotb, Mohamed; El-Hamamsy, Mostafa; El-Sonbaty, Mohamed; Abdel-Badie, Hazem; Zynabdeen, Mustapha
2010-08-01
Nasal encephalocele may presents as a nasal mass, its treatment is surgical and it should be done early in life. When removal is indicated, there are multiple surgical approaches; including lateral rhinotomy, a transnasal approach and a coronal flap approach. However, the treatment of a basal intranasal encephalocele using transnasal endoscopic approach could obviates the possible morbidity associated with other approaches. The aim of this study was to evaluate the efficacy of endoscopic removal of intranasal encephalocele, also to document the role of anesthetist in the operative and postoperative periods. Nine cases with nasal encephalocele were included in this study; CT and/or MRI were used in their examination. The lesions were removed via transnasal endoscopic approach. Preoperative evaluation, intervention and postoperative follow-up were presented with discussion of anesthesia used for those children. The lesions of all patients were removed successfully with no recurrence through the follow-up period of at least 21 months. No cases showed morbidity or mortality intra- or post-operatively. Endoscopic excision of intranasal encephalocele is an effective method with high success rate. Anesthetist plays an important role in the operative and postoperative period, even during the endoscopic follow up; sedation of the children is usually needed. Copyright (c) 2010 Elsevier Ireland Ltd. All rights reserved.
Transanal endoscopic microsurgery: a New Zealand experience.
Bloomfield, Ian; Van Dalen, Roelof; Lolohea, Simione; Wu, Linus
2017-12-03
Transanal endoscopic microsurgery (TEMS) is a proven alternative therapy to either radical surgery or endoscopic mucosal resection for rectal neoplasms. It has proven benefits with lower morbidity and mortality compared with total mesorectal excision, and a lower local recurrence rate when compared to endoscopic mucosal techniques. A retrospective data collection of TEMS procedures performed through Waikato District Health Board, New Zealand, from 2010 to 2015 was conducted. Supportive follow-up data were sourced from patient records and from local centres around New Zealand. A total of 137 procedures were performed over the study period, with five being repeat procedures. Procedures were mostly performed for benign lesions (66.4%) with an overall complication rate of 15.3%, only five of which were Clavien-Dindo grade III (3.6%). Our local recurrence rate after resection of benign lesions was 5.1%. Our data set demonstrates the TEMS procedure to be safe compared to radical resection (total mesorectal excision) for sessile rectal lesions. Close endoscopic follow-up is recommended, especially for close or incomplete margins. Good therapeutic results can be obtained for appropriately selected early malignant lesions. TEMS provides better oncological results than endoscopic mucosal resection or transanal excision. © 2017 Royal Australasian College of Surgeons.
Volonté, Francesco; Buchs, Nicolas C; Pugin, François; Spaltenstein, Joël; Schiltz, Boris; Jung, Minoa; Hagen, Monika; Ratib, Osman; Morel, Philippe
2013-09-01
Computerized management of medical information and 3D imaging has become the norm in everyday medical practice. Surgeons exploit these emerging technologies and bring information previously confined to the radiology rooms into the operating theatre. The paper reports the authors' experience with integrated stereoscopic 3D-rendered images in the da Vinci surgeon console. Volume-rendered images were obtained from a standard computed tomography dataset using the OsiriX DICOM workstation. A custom OsiriX plugin was created that permitted the 3D-rendered images to be displayed in the da Vinci surgeon console and to appear stereoscopic. These rendered images were displayed in the robotic console using the TilePro multi-input display. The upper part of the screen shows the real endoscopic surgical field and the bottom shows the stereoscopic 3D-rendered images. These are controlled by a 3D joystick installed on the console, and are updated in real time. Five patients underwent a robotic augmented reality-enhanced procedure. The surgeon was able to switch between the classical endoscopic view and a combined virtual view during the procedure. Subjectively, the addition of the rendered images was considered to be an undeniable help during the dissection phase. With the rapid evolution of robotics, computer-aided surgery is receiving increasing interest. This paper details the authors' experience with 3D-rendered images projected inside the surgical console. The use of this intra-operative mixed reality technology is considered very useful by the surgeon. It has been shown that the usefulness of this technique is a step toward computer-aided surgery that will progress very quickly over the next few years. Copyright © 2012 John Wiley & Sons, Ltd.
Per-oral endoscopic myotomy (POEM) for esophageal achalasia.
Pescarus, Radu; Shlomovitz, Eran; Swanstrom, Lee L
2014-01-01
Per-oral endoscopic myotomy (POEM) is a new minimally invasive endoscopic treatment for achalasia. Since the first modern human cases were published in 2008, around 2,000 cases have been performed worldwide. This technique requires advanced endoscopic skills and a learning curve of at least 20 cases. POEM is highly successful with over 90 % improvement in dysphagia while offering patients the advantage of a low impact endoscopic access. The main long-term complication is gastroesophageal reflux (GER) with an estimated incidence of 35 %, similar to the incidence of GER post-laparoscopic Heller with fundoplication. Although POEM represents a paradigm shift in the treatment of achalasia, more long-term data are clearly needed to further define its role in the treatment algorithm of this rare disease.
Whitesides, George M
2018-04-09
This description of "soft robotics" is not intended to be a conventional review, in the sense of a comprehensive technical summary of a developing field. Rather, its objective is to describe soft robotics as a new field-one that offers opportunities to chemists and materials scientists who like to make "things" and to work with macroscopic objects that move and exert force. It will give one (personal) view of what soft actuators and robots are, and how this class of soft devices fits into the more highly developed field of conventional "hard" robotics. It will also suggest how and why soft robotics is more than simply a minor technical "tweak" on hard robotics and propose a unique role for chemistry, and materials science, in this field. Soft robotics is, at its core, intellectually and technologically different from hard robotics, both because it has different objectives and uses and because it relies on the properties of materials to assume many of the roles played by sensors, actuators, and controllers in hard robotics. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Remirez, Andria A.; Webster, Robert J.
2016-03-01
Many applications in medicine require flexible surgical manipulators and endoscopes capable of reaching tight curvatures. The maximum curvature these devices can achieve is often restricted either by a strain limit, or by a maximum actuation force that the device's components can tolerate without risking mechanical failure. In this paper we propose the use of precurvature to "bias" the workspace of the device in one direction. Combined with axial shaft rotation, biasing increases the size of the device's workspace, enabling it to reach tighter curvatures than a comparable device without biasing can achieve, while still being able to fully straighten. To illustrate this effect, we describe several example prototype devices which use flexible nitinol strips that can be pushed and pulled to generate bending. We provide a statics model that relates the manipulator curvature to actuation force, and validate it experimentally.
Wide-field phase imaging for the endoscopic detection of dysplasia and early-stage esophageal cancer
Fitzpatrick, C. R. M.; Gordon, G. S. D.; Sawyer, T. W.; Wilkinson, T. D.; Bohndiek, S. E.
2018-02-01
Esophageal cancer has a 5-year survival rate below 20%, but can be curatively resected if it is detected early. At present, poor contrast for early lesions in white light imaging leads to a high miss rate in standard-of- care endoscopic surveillance. Early lesions in the esophagus, referred to as dysplasia, are characterized by an abundance of abnormal cells with enlarged nuclei. This tissue has a different refractive index profile to healthy tissue, which results in different light scattering properties and provides a source of endogenous contrast that can be exploited for advanced endoscopic imaging. For example, point measurements of such contrast can be made with scattering spectroscopy, while optical coherence tomography generates volumetric data. However, both require specialist interpretation for diagnostic decision making. We propose combining wide-field phase imaging with existing white light endoscopy in order to provide enhanced contrast for dysplasia and early-stage cancer in an image format that is familiar to endoscopists. Wide-field phase imaging in endoscopy can be achieved using coherent illumination combined with phase retrieval algorithms. Here, we present the design and simulation of a benchtop phase imaging system that is compatible with capsule endoscopy. We have undertaken preliminary optical modelling of the phase imaging setup, including aberration correction simulations and an investigation into distinguishing between different tissue phantom scattering coefficients. As our approach is based on phase retrieval rather than interferometry, it is feasible to realize a device with low-cost components for future clinical implementation.
New developments in endoscopic treatment of chronic pancreatitis.
Didden, P; Bruno, M; Poley, J W
2012-12-01
The aim of endoscopic therapy of chronic pancreatitis (CP) is to treat pain by draining the pancreatic duct or managing loco-regional complications. Recent decennia were characterized by continuous improvement of endoscopic techniques and devices, resulting in a better clinical outcome. Novel developments now also provide the opportunity to endoscopically treat refractory CP-related complications. Especially suboptimal surgical candidates could potentially benefit from these new developments, consequently avoiding invasive surgery. The use of fully covered self-expandable metal stents (SEMS) has been explored in pancreatic and CP-related biliary duct strictures, resistant to conventional treatment with plastic endoprotheses. Furthermore, endosonography-guided transmural drainage of the main pancreatic duct via duct-gastrostomy is an alternative treatment option in selected cases. Pancreatic pseudocysts represent an excellent indication for endoscopic therapy with some recent case series demonstrating effective drainage with the use of a fully covered SEMS. Although results of these new endoscopic developments are promising, high quality randomized trials are required to determine their definite role in the management of chronic pancreatitis.
Inverse dynamic analysis of general n-link robot manipulators
International Nuclear Information System (INIS)
Yih, T.C.; Wang, T.Y.; Burks, B.L.; Babcock, S.M.
1996-01-01
In this paper, a generalized matrix approach is derived to analyze the dynamic forces and moments (torques) required by the joint actuators. This method is general enough to solve the problems of any n-link open-chain robot manipulators with joint combinations of R(revolute), P(prismatic), and S(spherical). On the other hand, the proposed matrix solution is applicable to both nonredundant and redundant robotic systems. The matrix notation is formulated based on the Newton-Euler equations under the condition of quasi-static equilibrium. The 4 x 4 homogeneous cylindrical coordinates-Bryant angles (C-B) notation is applied to model the robotic systems. Displacements, velocities, and accelerations of each joint and link center of gravity (CG) are calculated through kinematic analysis. The resultant external forces and moments exerted on the CG of each link are considered as known inputs. Subsequently, a 6n x 6n displacement coefficient matrix and a 6n x 1 external force/moment vector can be established. At last, the joint forces and moments needed for the joint actuators to control the robotic system are determined through matrix inversion. Numerical examples will be illustrated for the nonredundant industrial robots: Bendix AA/CNC (RRP/RRR) and Unimate 2000 spherical (SP/RRR) robots; and the redundant light duty utility arm (LDUA), modified LDUA, and tank waste retrieval manipulator system
Surgical management of failed endoscopic treatment of pancreatic disease.
Evans, Kimberly A; Clark, Colby W; Vogel, Stephen B; Behrns, Kevin E
2008-11-01
Endoscopic therapy of acute and chronic pancreatitis has decreased the need for operative intervention. However, a significant proportion of patients treated endoscopically require definitive surgical management for persistent symptoms. Our aim was to determine which patients are likely to fail with endoscopic therapy, and to assess the clinical outcome of surgical management. Patients were identified using ICD-9 codes for pancreatic disease as well as CPT codes for endoscopic therapy followed by surgery. Patients with documented acute or chronic pancreatitis treated endoscopically prior to surgical therapy were included (N = 88). The majority of patients (65%) exhibited chronic pancreatitis due to alcohol abuse. Common indicators for surgery were: persistent symptoms, anatomy not amenable to endoscopic treatment and unresolved common bile duct or pancreatic duct strictures. Surgical salvage procedures included internal drainage of a pseudocyst or an obstructed pancreatic duct (46%), debridement of peripancreatic fluid collections (25%), and pancreatic resection (31%). Death occurred in 3% of patients. The most common complications were hemorrhage (16%), wound infection (13%), and pulmonary complications (11%). Chronic pancreatitis with persistent symptoms is the most common reason for pancreatic surgery following endoscopic therapy. Surgical salvage therapy can largely be accomplished by drainage procedures, but pancreatic resection is common. These complex procedures can be performed with acceptable mortality but also with significant risk for morbidity.
International Nuclear Information System (INIS)
Aoyama, Yoshiko; Sawada, Tetsuo; Fujii, Yasuhiko
2008-01-01
In order to alleviate the distrust surrounding the use of nuclear energy and operation of nuclear facilities, as well as to foster trust and find better ways to live in harmony with society, it is essential for the state and electric power utilities not to provide one-sided information, but to formulate adequate bilateral communication and dialogue with stake holders. In this study, we conducted a case study focused on four stake holder meetings with a view to ensuring safety in the use of nuclear energy and operation of nuclear facilities in Japan; the 'Community Meeting for Securing the Transparency of Kashiwazaki-Kariwa Nuclear Power Station (Chiiki-no-kai)'; the 'Monitoring and Evaluation Conference on Environmental Radiation', established by communities where nuclear facilities are installed; the 'Round-Table Conference on Nuclear Power Policy' and the 'Conference for Public Participation and Decision Making for Nuclear Energy Policy' organized by Japan Atomic Energy Commission. As a consequence, it has been observed that in each case varying opinions were summarized through stake holder meetings, but the fact that no system exists to reflect these opinions in design of the nuclear energy policy has emerged as a controversial point. This study suggests future efforts in regard to the requirements in Japan for stake holder meetings that are necessary for fostering trust and mutual understanding among stake holders including the state and local government, electric power utilities and local residents. (author)
Calibration procedures of the Tore-Supra infrared endoscopes
Desgranges, C.; Jouve, M.; Balorin, C.; Reichle, R.; Firdaouss, M.; Lipa, M.; Chantant, M.; Gardarein, J. L.; Saille, A.; Loarer, T.
2018-01-01
Five endoscopes equipped with infrared cameras working in the medium infrared range (3-5 μm) are installed on the controlled thermonuclear fusion research device Tore-Supra. These endoscopes aim at monitoring the plasma facing components surface temperature to prevent their overheating. Signals delivered by infrared cameras through endoscopes are analysed and used on the one hand through a real time feedback control loop acting on the heating systems of the plasma to decrease plasma facing components surface temperatures when necessary, on the other hand for physics studies such as determination of the incoming heat flux . To ensure these two roles a very accurate knowledge of the absolute surface temperatures is mandatory. Consequently the infrared endoscopes must be calibrated through a very careful procedure. This means determining their transmission coefficients which is a delicate operation. Methods to calibrate infrared endoscopes during the shutdown period of the Tore-Supra machine will be presented. As they do not allow determining the possible transmittances evolution during operation an in-situ method is presented. It permits the validation of the calibration performed in laboratory as well as the monitoring of their evolution during machine operation. This is possible by the use of the endoscope shutter and a dedicated plasma scenario developed to heat it. Possible improvements of this method are briefly evoked.
Atkinson, Matthew; Chukwumah, Chike; Marks, Jeffrey; Chak, Amitabh
2014-02-01
Flat and depressed lesions are becoming increasingly recognized in the esophagus, stomach, and colon. Various techniques have been described for endoscopic mucosal resection (EMR) of these lesions. To evaluate the efficacy of lift-grasp-cut EMR using a prototype dual-channel forward-viewing endoscope with an instrument elevator in one accessory channel (dual-channel elevator scope) as compared to standard dual-channel endoscopes. EMR was performed using a lift-grasp-cut technique on normal flat rectosigmoid or gastric mucosa in live porcine models after submucosal injection of 4 mL of saline using a dual-channel elevator scope or a standard dual-channel endoscope. With the dual-channel elevator scope, the elevator was used to attain further lifting of the mucosa. The primary endpoint was size of the EMR specimen and the secondary endpoint was number of complications. Twelve experiments were performed (six gastric and six colonic). Mean specimen diameter was 2.27 cm with the dual-channel elevator scope and 1.34 cm with the dual-channel endoscope (P = 0.018). Two colonic perforations occurred with the dual-channel endoscope, vs no complications with the dual-channel elevator scope. The increased lift of the mucosal epithelium, through use of the dual-channel elevator scope, allows for larger EMR when using a lift-grasp-cut technique. Noting the thin nature of the porcine colonic wall, use of the elevator may also make this technique safer.
Visual Detection and Tracking System for a Spherical Amphibious Robot.
Guo, Shuxiang; Pan, Shaowu; Shi, Liwei; Guo, Ping; He, Yanlin; Tang, Kun
2017-04-15
With the goal of supporting close-range observation tasks of a spherical amphibious robot, such as ecological observations and intelligent surveillance, a moving target detection and tracking system was designed and implemented in this study. Given the restrictions presented by the amphibious environment and the small-sized spherical amphibious robot, an industrial camera and vision algorithms using adaptive appearance models were adopted to construct the proposed system. To handle the problem of light scattering and absorption in the underwater environment, the multi-scale retinex with color restoration algorithm was used for image enhancement. Given the environmental disturbances in practical amphibious scenarios, the Gaussian mixture model was used to detect moving targets entering the field of view of the robot. A fast compressive tracker with a Kalman prediction mechanism was used to track the specified target. Considering the limited load space and the unique mechanical structure of the robot, the proposed vision system was fabricated with a low power system-on-chip using an asymmetric and heterogeneous computing architecture. Experimental results confirmed the validity and high efficiency of the proposed system. The design presented in this paper is able to meet future demands of spherical amphibious robots in biological monitoring and multi-robot cooperation.
Visual Detection and Tracking System for a Spherical Amphibious Robot
Guo, Shuxiang; Pan, Shaowu; Shi, Liwei; Guo, Ping; He, Yanlin; Tang, Kun
2017-01-01
With the goal of supporting close-range observation tasks of a spherical amphibious robot, such as ecological observations and intelligent surveillance, a moving target detection and tracking system was designed and implemented in this study. Given the restrictions presented by the amphibious environment and the small-sized spherical amphibious robot, an industrial camera and vision algorithms using adaptive appearance models were adopted to construct the proposed system. To handle the problem of light scattering and absorption in the underwater environment, the multi-scale retinex with color restoration algorithm was used for image enhancement. Given the environmental disturbances in practical amphibious scenarios, the Gaussian mixture model was used to detect moving targets entering the field of view of the robot. A fast compressive tracker with a Kalman prediction mechanism was used to track the specified target. Considering the limited load space and the unique mechanical structure of the robot, the proposed vision system was fabricated with a low power system-on-chip using an asymmetric and heterogeneous computing architecture. Experimental results confirmed the validity and high efficiency of the proposed system. The design presented in this paper is able to meet future demands of spherical amphibious robots in biological monitoring and multi-robot cooperation. PMID:28420134
International Nuclear Information System (INIS)
Asha, V.S.; Arulmozhiselvan, K.
2006-01-01
In order to estimate N use efficiency in deep placement of NPK straight fertilizers, two pot experiments were conducted in high clay soil with direct seeded rice. 15 N urea was used as a tracer. A newly designed 'Nutriseed Holder' was used for simultaneous deep placement of fertilizers and sowing of seeds. Each holder had two cavities, one on top for holding seed and another one at bottom for holding fertilizer material. By implanting a holder in puddled soil, a rice hill was established. The length (5 or 10 cm) and width (8 or 12 mm) of nutriseed holder was standardized while evaluating the effect of Azolla, neem and seed inoculants. Appreciably, deep placement of plain NPK fertilizer in 12 mm holder placed at 5 cm depth recorded the highest grain yield with a yield increase of 81.8 per cent during rabi 2002 (cv CO 43) and 84.8 per cent during summer 2003 (cv CO 47) over broadcast application. Further, it increased recovery of added JSN in grain + straw to the tune of 57.1 per cent in rabi and 54.7 per cent in summer as compared to broadcast application (26.1% in rabi, 34.2 in summer). Deep placement enhanced more retention in soil (up to 9.0% in rabi, 14.6% in summer) whereas broadcast application enhanced more retention in Azolla biomass that was grown in floodwater (up to 2.3 % in rabi, 4.3 % in summer). Use of 12 mm width nutriseed holder aiding deep placement at 5 cm depth was found suitable for deriving high yield and N use efficiency. (author)
Endoscopic Rectus Abdominis and Prepubic Aponeurosis Repairs for Treatment of Athletic Pubalgia.
Matsuda, Dean K; Matsuda, Nicole A; Head, Rachel; Tivorsak, Tanya
2017-02-01
Review of the English orthopaedic literature reveals no prior report of endoscopic repair of rectus abdominis tears and/or prepubic aponeurosis detachment. This technical report describes endoscopic reattachment of an avulsed prepubic aponeurosis and endoscopic repair of a vertical rectus abdominis tear immediately after endoscopic pubic symphysectomy for coexistent recalcitrant osteitis pubis as a single-stage outpatient surgery. Endoscopic rectus abdominis repair and prepubic aponeurosis repair are feasible surgeries that complement endoscopic pubic symphysectomy for patients with concurrent osteitis pubis and expand the less invasive options for patients with athletic pubalgia.
Exploiting Child-Robot Aesthetic Interaction for a Social Robot
Lee, Jae-Joon; Kim, Dae-Won; Kang, Bo-Yeong
2012-01-01
A social robot interacts and communicates with humans by using the embodied knowledge gained from interactions with its social environment. In recent years, emotion has emerged as a popular concept for designing social robots. Several studies on social robots reported an increase in robot sociability through emotional imitative interactions between the robot and humans. In this paper conventional emotional interactions are extended by exploiting the aesthetic theories that the sociability of ...
Light Robotics Structure-mediated Nanobiophotonics
DEFF Research Database (Denmark)
Glückstad, Jesper; Palima, Darwin
2017-01-01
Scientific disciplines constantly evolve and create new offspring—subdisciplines— that combine the favorable characteristics from its forerunners. The merger of biology and photonics has within the last decade produced one such offspring, Biophotonics, which harnesses light to study biological mat...... the contributors from across four continents to whom we owe a debt of gratitude for the time, effort, and expertise devoted into formulating their respective chapters. Thank you very much!...
Directory of Open Access Journals (Sweden)
Keunmo Kim
2017-03-01
Full Text Available Endoscopic closure techniques have been introduced for the repair of duodenal wall perforations that occur during endoscopic retrograde cholangiopancreatography (ERCP. We report a case of successful repair of a large duodenal wall perforation by using double endoscopic band ligation (EBL and an endoclip. Lateral duodenal wall perforation occurred during ERCP in a 93-year-old woman with acute calculous cholangitis. We switched to a forward endoscope that had a transparent band apparatus. A 2.0-cm oval-shaped perforation was found at the lateral duodenal wall. We repaired the perforation by sequentially performing double EBL and endoclipping. The first EBL was performed at the proximal edge of the perforation orifice, and two-thirds of the perforation were repaired. The second EBL, which also included the contents covered under the first EBL, repaired the defect almost completely. Finally, to account for the possible presence of a residual perforation, an endoclip was applied at the distal end of the perforation. The detection and closure of the perforation were completed within 10 minutes. We suggest that double EBL is an effective method for closure.
Endoscopic brow lifts uber alles.
Patel, Bhupendra C K
2006-12-01
Innumerable approaches to the ptotic brow and forehead have been described in the past. Over the last twenty-five years, we have used all these techniques in cosmetic and reconstructive patients. We have used the endoscopic brow lift technique since 1995. While no one technique is applicable to all patients, the endoscopic brow lift, with appropriate modifications for individual patients, can be used effectively for most patients with brow ptosis. We present the nuances of this technique and show several different fixation methods we have found useful.
Evaluation of the tip-bending response in clinically used endoscopes
Rozeboom, Esther; Reilink, Rob; Schwartz, Matthijs P.; Fockens, Paul; Broeders, Ivo Adriaan Maria Johannes
Background and study aims: Endoscopic interventions require accurate and precise control of the endoscope tip. The endoscope tip response depends on a cable pulling system, which is known to deliver a significantly nonlinear response that eventually reduces control. It is unknown whether the current
Evaluation of the tip-bending response in clinically used endoscopes
Rozeboom, Esther D.; Reilink, Rob; Schwartz, Matthijs P.; Fockens, Paul; Broeders, Ivo A. M. J.
2016-01-01
Background and study aims: Endoscopic interventions require accurate and precise control of the endoscope tip. The endoscope tip response depends on a cable pulling system, which is known to deliver a significantly nonlinear response that eventually reduces control. It is unknown whether the current
SIMON: A mobile robot for floor contamination surveys
International Nuclear Information System (INIS)
Dudar, E.; Teese, G.; Wagner, D.
1991-01-01
The Robotics Development group at the Savannah River Site is developing an autonomous robot to perform radiological surveys of potentially contaminated floors. The robot scans floors at a speed of one-inch/second and stops, sounds an alarm, and flashes lights when contamination in a certain area is detected. The contamination of interest here is primarily alpha and beta-gamma. The contamination levels are low to moderate. The robot, a Cybermotion K2A, is radio controlled, uses dead reckoning to determine vehicle position, and docks with a charging station to replenish its batteries and calibrate its position. It has an ultrasonic collision avoidance system as well as two safety bumpers that will stop the robot's motion when they are depressed. Paths for the robot are preprogrammed and the robot's motion can be monitored on a remote screen which shows a graphical map of the environment. The radiation instrument being used is an Eberline RM22A monitor. This monitor is microcomputer based with a serial I/O interface for remote operation. Up to 30 detectors may be configured with the RM22A. For our purposes, two downward-facing gas proportional detectors are used to scan floors, and one upward-facing detector is used for radiation background compensation. SIMON is interfaced with the RM22A in such a way that it scans the floor surface at one-inch/second, and if contamination is detected, the vehicle stops, alarms, and activates a voice synthesizer. Future development includes using the contamination data collected to provide a graphical contour map of a contaminated area. 3 refs
Indian Academy of Sciences (India)
In evolutionary robotics, a suitable robot control system is developed automatically through evolution due to the interactions between the robot and its environment. It is a complicated task, as the robot and the environment constitute a highly dynamical system. Several methods have been tried by various investigators to ...
Tate, David J; Jayanna, Mahesh; Awadie, Halim; Desomer, Lobke; Lee, Ralph; Heitman, Steven J; Sidhu, Mayenaaz; Goodrick, Kathleen; Burgess, Nicholas G; Mahajan, Hema; McLeod, Duncan; Bourke, Michael J
2018-01-01
Dysplasia within sessile serrated polyps (SSPs) is difficult to detect and may be mistaken for an adenoma, risking incomplete resection of the background serrated tissue, and is strongly implicated in interval cancer after colonoscopy. The use of endoscopic imaging to detect dysplasia within SSPs has not been systematically studied. Consecutively detected SSPs ≥8 mm in size were evaluated by using a standardized imaging protocol at a tertiary-care endoscopy center over 3 years. Lesions suspected as SSPs were analyzed with high-definition white light then narrow-band imaging. A demarcated area with a neoplastic pit pattern (Kudo type III/IV, NICE type II) was sought among the serrated tissue. If this was detected, the lesion was labeled dysplastic (sessile serrated polyp with dysplasia); if not, it was labeled non-dysplastic (sessile serrated polyp without dysplasia). Histopathology was reviewed by 2 blinded specialist GI pathologists. A total of 141 SSPs were assessed in 83 patients. Median lesion size was 15.0 mm (interquartile range 10-20), and 54.6% were in the right side of the colon. Endoscopic evidence of dysplasia was detected in 36 of 141 (25.5%) SSPs; of these, 5 of 36 (13.9%) lacked dysplasia at histopathology. Two of 105 (1.9%) endoscopically designated non-dysplastic SSPs had dysplasia at histopathology. Endoscopic imaging, therefore, had an accuracy of 95.0% (95% confidence interval [CI], 90.1%-97.6%) and a negative predictive value of 98.1% (95% CI, 92.6%-99.7%) for detection of dysplasia within SSPs. Dysplasia within SSPs can be detected accurately by using a simple, broadly applicable endoscopic imaging protocol that allows complete resection. Independent validation of this protocol and its dissemination to the wider endoscopic community may have a significant impact on rates of interval cancer. (Clinical trial registration number: NCT03100552.). Copyright © 2018 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All
Micromotor endoscope catheter for in vivo, ultrahigh-resolution optical coherence tomography
Herz, P. R.; Chen, Y.; Aguirre, A. D.; Schneider, K.; Hsiung, P.; Fujimoto, J. G.; Madden, K.; Schmitt, J.; Goodnow, J.; Petersen, C.
2004-10-01
A distally actuated, rotational-scanning micromotor endoscope catheter probe is demonstrated for ultrahigh-resolution in vivo endoscopic optical coherence tomography (OCT) imaging. The probe permits focus adjustment for visualization of tissue morphology at varying depths with improved transverse resolution compared with standard OCT imaging probes. The distal actuation avoids nonuniform scanning motion artifacts that are present with other probe designs and can permit a wider range of imaging speeds. Ultrahigh-resolution endoscopic imaging is demonstrated in a rabbit with micromotor endoscope catheter probe promises to improve OCT imaging performance in future endoscopic imaging applications.
Interactive Exploration Robots: Human-Robotic Collaboration and Interactions
Fong, Terry
2017-01-01
For decades, NASA has employed different operational approaches for human and robotic missions. Human spaceflight missions to the Moon and in low Earth orbit have relied upon near-continuous communication with minimal time delays. During these missions, astronauts and mission control communicate interactively to perform tasks and resolve problems in real-time. In contrast, deep-space robotic missions are designed for operations in the presence of significant communication delay - from tens of minutes to hours. Consequently, robotic missions typically employ meticulously scripted and validated command sequences that are intermittently uplinked to the robot for independent execution over long periods. Over the next few years, however, we will see increasing use of robots that blend these two operational approaches. These interactive exploration robots will be remotely operated by humans on Earth or from a spacecraft. These robots will be used to support astronauts on the International Space Station (ISS), to conduct new missions to the Moon, and potentially to enable remote exploration of planetary surfaces in real-time. In this talk, I will discuss the technical challenges associated with building and operating robots in this manner, along with lessons learned from research conducted with the ISS and in the field.
Endoscopic and Photodynamic Therapy of Cholangiocarcinoma.
Meier, Benjamin; Caca, Karel
2016-12-01
Most patients with cholangiocarcinoma (CCA) have unresectable disease. Endoscopic bile duct drainage is one of the major objectives of palliation of obstructive jaundice. Stent implantation using endoscopic retrograde cholangiography is considered to be the standard technique. Unilateral versus bilateral stenting is associated with different advantages and disadvantages; however, a standard approach is still not defined. As there are various kinds of stents, there is an ongoing discussion on which stent to use in which situation. Palliation of obstructive jaundice can be augmented through the use of photodynamic therapy (PDT). Studies have shown a prolonged survival for the combinations of PDT and different stent applications as well as combinations of PDT and additional systemic chemotherapy. More well-designed studies are needed to better evaluate and standardize endoscopic treatment of unresectable CCA.
A remotely operated robot for decontamination tasks
International Nuclear Information System (INIS)
Dudar, A.M.; Vandewalle, R.C.
1994-01-01
Engineers in the Robotics Development Group at the Westinghouse Savannah River Company (WSRC) have developed a robot which will be used to decontaminate a pipe gallery of a tank farm used for nuclear waste storage. Personnel access is required into this pipe gallery to inspect existing pipes and perform repairs to secondary containment walls around the tank farm. Presently, the pipe gallery is littered with debris of various sizes and its surface is contaminated with activity levels up to 2.5E6 DPM (disintegrations per minute) alpha and exposure levels as high as 20 Rad/hr. Cleaning up this pipe gallery win be the mission of an all-hydraulic robotic vehicle developed in-house at WSRC caged the ''Remote Decon'' robot. The Remote Decon is a tracked vehicle which utilizes skid steering and features a six-degree-of-freedom (DOF) manipulator arm, a five-DOF front end loader type bucket with a rotating brush for scrubbing and decontaminating surfaces, and a three-DOF pan/tilt mechanism with cameras and lights. The Remote Decon system is connected to a control console via a 200 foot tethered cable. The control console was designed with ergonomics and simplicity as the main design factors and features three joysticks, video monitors, LED panels, and audible alarms
Supraretinacular endoscopic carpal tunnel release: surgical technique with prospective case series.
Ecker, J; Perera, N; Ebert, J
2015-02-01
Current techniques for endoscopic carpal tunnel release use an infraretinacular approach, inserting the endoscope deep to the flexor retinaculum. We present a supraretinacular endoscopic carpal tunnel release technique in which a dissecting endoscope is inserted superficial to the flexor retinaculum, which improves vision and the ability to dissect and manipulate the median nerve and tendons during surgery. The motor branch of the median nerve and connections between the median and ulnar nerve can be identified and dissected. Because the endoscope is inserted superficial to the flexor retinaculum, the median nerve is not compressed before division of the retinaculum and, as a result, we have observed no cases of the transient median nerve deficits that have been reported using infraretinacular endoscopic techniques. © The Author(s) 2014.
Endoscopic laser-urethroplasty
Gilbert, Peter
2006-02-01
The objective was to prove the advantage of endoscopic laser-urethroplasty over internal urethrotomy in acquired urethral strictures. Patients and Method: From January, 1996 to June, 2005, 35 patients with a mean age of 66 years were submitted to endoscopic laser-urethroplasty for strictures of either the bulbar (30) or membranous (5) urethra. The operations were carried out under general anesthesia. First of all, the strictures were incised at the 4, 8 and 12 o'clock position by means of a Sachse-urethrotom. Then the scar flap between the 4 and 8 o'clock position was vaporized using a Nd:YAG laser, wavelength 1060 nm and a 600 pm bare fiber, the latter always being in contact with the tissue. The laser worked at 40W power in continuous mode. The total energy averaged 2574 J. An indwelling catheter was kept in place overnight and the patients were discharged the following day. Urinalysis, uroflowmetry and clinical examination were performed at two months after surgery and from then on every six months. Results: No serious complications were encountered. Considering a mean follow-up of 18 months, the average peak flow improved from 7.3 ml/s preoperatively to 18.7 mVs postoperatively. The treatment faded in 5 patients ( 14.3% ) who finally underwent open urethroplasty. Conclusions: Endoscopic laser-urethroplasty yields better short-term results than internal visual urethrotomy. Long-term follow-up has yet to confirm its superiority in the treatment of acquired urethral strictures.
Design and burn-up analyses of new type holder for silicon neutron transmutation doping.
Komeda, Masao; Arai, Masaji; Tamai, Kazuo; Kawasaki, Kozo
2016-07-01
We have developed a new silicon irradiation holder with a neutron filter to increase the irradiation efficiency. The neutron filter is made of an alloy of aluminum and B4C particles. We fabricated a new holder based on the results of design analyses. This filter has limited use in applications requiring prolonged use due to a decrease in the amount of (10)B in B4C particles. We investigated the influence of (10)B reduction on doping distribution in a silicon ingot by using the Monte Carlo Code MVP. Copyright © 2016 Elsevier Ltd. All rights reserved.
Endoscopic surgery of the nose and paranasal sinus.
Palmer, Orville; Moche, Jason A; Matthews, Stanley
2012-05-01
Mucosal preservation is of paramount importance in the diagnosis and surgical management of the sinonasal tract. The endoscope revolutionized the practice of endoscopic nasal surgery. As a result, external sinus surgery is performed less frequently today, and more emphasis is placed on functional endoscopy and preservation of normal anatomy. Endoscopic surgery of the nose and paranasal sinus has provided improved surgical outcomes and has shortened the length of stay in hospital. It has also become a valuable teaching tool. Copyright © 2012 Elsevier Inc. All rights reserved.
ROBOT LITERACY AN APPROACH FOR SHARING SOCIETY WITH INTELLIGENT ROBOTS
Directory of Open Access Journals (Sweden)
Hidetsugu Suto
2013-12-01
Full Text Available A novel concept of media education called “robot literacy” is proposed. Here, robot literacy refers to the means of forming an appropriate relationship with intelligent robots. It can be considered a kind of media literacy. People who were born after the Internet age can be considered “digital natives” who have new morals and values and behave differently than previous generations in Internet societies. This can cause various problems among different generations. Thus, the necessity of media literacy education is increasing. Internet technologies, as well as robotics technologies are growing rapidly, and people who are born after the “home robot age,” whom the author calls “robot natives,” will be expected to have a certain degree of “robot literacy.” In this paper, the concept of robot literacy is defined and an approach to robot literacy education is discussed.
Current Status of Peroral Endoscopic Myotomy
Cho, Young Kwan; Kim, Seong Hwan
2018-01-01
Peroral endoscopic myotomy (POEM) has been established as an optional treatment for achalasia. POEM is an endoluminal procedure that involves dissection of esophageal muscle fibers followed by submucosal tunneling. Inoue first attempted to use POEM for the treatment of achalasia in humans. Expanded indications of POEM include classic indications such as type I, type II, type III achalasia, failed prior treatments, including Botulinum toxin injection, endoscopic balloon dilation, laparoscopic ...
Bier, H.H.
2014-01-01
Technological and conceptual advances in fields such as artificial intelligence, robotics, and material science have enabled robotic building to be in the last decade prototypically implemented. In this context, robotic building implies both physically built robotic environments and robotically
Directory of Open Access Journals (Sweden)
Busra Koken
2015-01-01
Full Text Available Cloud robotics is a rapidly evolving field that allows robots to offload computation-intensive and storage-intensive jobs into the cloud. Robots are limited in terms of computational capacity, memory and storage. Cloud provides unlimited computation power, memory, storage and especially collaboration opportunity. Cloud-enabled robots are divided into two categories as standalone and networked robots. This article surveys cloud robotic platforms, standalone and networked robotic works such as grasping, simultaneous localization and mapping (SLAM and monitoring.
Distributed Robotics Education
DEFF Research Database (Denmark)
Lund, Henrik Hautop; Pagliarini, Luigi
2011-01-01
Distributed robotics takes many forms, for instance, multirobots, modular robots, and self-reconfigurable robots. The understanding and development of such advanced robotic systems demand extensive knowledge in engineering and computer science. In this paper, we describe the concept of a distribu......Distributed robotics takes many forms, for instance, multirobots, modular robots, and self-reconfigurable robots. The understanding and development of such advanced robotic systems demand extensive knowledge in engineering and computer science. In this paper, we describe the concept...... to be changed, related to multirobot control and human-robot interaction control from virtual to physical representation. The proposed system is valuable for bringing a vast number of issues into education – such as parallel programming, distribution, communication protocols, master dependency, connectivity...
International Nuclear Information System (INIS)
Piotrowski, L.; Trouville, B.; Halbach, M.; Sidorkin, N.
1996-12-01
The primary objective of the IMPACT project is to develop a light-weight and inexpensive mobile robot that can be used for rapid inspection missions within nuclear power plants. These interventions are to cover normal, incident and accident situations and aim at primary reconnaissance (or 'data collecting') missions. The IMPACT robot was demonstrated (April 1996) in a realistic mission at the Russian nuclear plant SMOLENSK. The demonstration, composed of 2 independent but consecutive missions, was held in a radioactive zone near turbine ≠ 4 of Unit 2: remote radiation mapping with localisation of radioactive sources by the IMPACT robot equipped with a (Russian) gamma-radiation sensor; deployment of a Russian intervention robot for the construction of a protective lead shield around one of the identified sources and verification that the ambient radiation level has been reduce. This mission was executed remotely by 2 mobile robots working in collaboration: a NIKIMT robot equipped with a manipulator arm and carrying leads bricks and the IMPACT robot of mission I (radiation measurements and 'side-observer'). This manuscript describes (a) the technical characteristics of the IMPACT reconnaissance robot (3-segmented, caterpillar-tracked body; 6 video cameras placed around the mobile platform with simultaneous presentation of up to 4 video images at the control post; ability to detach remotely one of the robot's segments (i.e. the robot can divide itself into 2 separate mobile robots)) and (b) the SMOLENSK demonstration. (author)
Assessing the authority of political office-holders : The leadership capital index
Bennister, Mark; t Hart, Paul; Worthy, Benjamin
2015-01-01
This article argues that the extent to which political office-holders can effectively attain and wield authority is a function of the stock of ‘leadership capital’. Drawing on the concept of political capital, the article defines leadership capital as aggregate authority composed of three
Holder pasteurization affects S100B concentrations in human milk.
Peila, Chiara; Coscia, Alessandra; Bertino, Enrico; Li Volti, Giovanni; Galvano, Fabio; Visser, Gerard H A; Gazzolo, Diego
2018-02-01
Donor milk (DM) represents an important nutrition source for high-risk newborns. Holder pasteurization (HoP) is the most recommended procedure for DM treatment, providing a good compromise between microbiological safety and biological quality. HoP was previously shown to affect DM cytokines, growth factors and hormones levels, whilst no data concerning the possible effects of HoP on neurobiomarkers (NB) are available. Therefore, our study investigated whether the concentration in DM of a well-known NB involved in brain development/damage, namely S100B, changes due to HoP. We conducted a pretest-test study in 11 mothers, whose DM samples were sub-divided into two parts: the first was immediately frozen (-80 °C); the second was pasteurized with Holder method before freezing. S100B DM levels were measured using a commercially available immunoluminometric assay. S100B protein was detected in all milk samples. Results showed significant differences between groups (p pasteurization stresses and the need to develop new storage techniques to preserve the biological quality of human milk.
Lenarcic, Jadran; Stanišić, Michael M
2013-01-01
This book provides a comprehensive introduction to the area of robot mechanisms, primarily considering industrial manipulators and humanoid arms. The book is intended for both teaching and self-study. Emphasis is given to the fundamentals of kinematic analysis and the design of robot mechanisms. The coverage of topics is untypical. The focus is on robot kinematics. The book creates a balance between theoretical and practical aspects in the development and application of robot mechanisms, and includes the latest achievements and trends in robot science and technology.
Directory of Open Access Journals (Sweden)
Rafael Aracil
2008-04-01
Full Text Available Resumen: El término Robots de Servicio apareció a finales de los años 80 como una necesidad de desarrollar máquinas y sistemas capaces de trabajar en entornos diferentes a los fabriles. Los Robots de Servicio tenían que poder trabajar en entornos noestructurados, en condiciones ambientales cambiantes y con una estrecha interacción con los humanos. En 1995 fue creado por la IEEE Robotics and Automation Society, el Technical Committee on Service Robots, y este comité definió en el año 2000 las áreas de aplicación de los Robots de Servicios, que se pueden dividir en dos grandes grupos: 1 sectores productivos no manufactureros tales como edificación, agricultura, naval, minería, medicina, etc. y 2 sectores de servicios propiamente dichos: asistencia personal, limpieza, vigilancia, educación, entretenimiento, etc. En este trabajo se hace una breve revisión de los principales conceptos y aplicaciones de los robots de servicio. Palabras clave: Robots de servicio, robots autónomos, robots de exteriores, robots de educación y entretenimiento, robots caminantes y escaladores, robots humanoides
Endoscopic Management of a Primary Duodenal Carcinoid Tumor
Directory of Open Access Journals (Sweden)
Albin Abraham
2012-03-01
Full Text Available Carcinoids are rare, slow-growing tumors originating from a variety of different neuroendocrine cell types. They are identified histologically by their affinity for silver salts and by positive reactions to neuroendocrine markers such as neuron-specific enolase, synaptophysin and chromogranin. They can present with various clinical symptoms and are difficult to diagnose. We present the case of a 43-year-old woman who was referred for evaluation of anemia. Upper endoscopy showed a duodenal bulb mass around 1 cm in size. Histopathological and immunohistochemistry staining were consistent with the diagnosis of a carcinoid tumor. Further imaging and endoscopic studies showed no other synchronous carcinoid lesions. Endoscopic ultrasound (EUS revealed a 1 cm lesion confined to the mucosa and no local lymphadenopathy. Successful endoscopic mucosal resection of the mass was performed. Follow-up surveillance 6 months later with EUS and Octreoscan revealed no new lesions suggestive of recurrence. No consensus guidelines exist for the endoscopic management of duodenal carcinoid tumors. However, endoscopic resection is safe and preferred for tumors measuring 1 cm or less with no evidence of invasion of the muscularis layer.
Advances in endoscopic surgery for small animal reproduction.
Katic, N; Dupré, G
2016-09-01
Although endoscopic surgery entered its "golden era" in the mid-1980s, it is still advancing at a tremendous pace. Novel surgical techniques and devices are continuously developed and applied, and new indications (and/or contraindications) for the use of endoscopic surgery are routinely reported in the literature and subjected to systematic assessments. Although endoscopic surgery (laparoscopy in particular) has already become established as the gold standard in human medicine, it has yet to be proven as a viable alternative to open surgery in the field of veterinary medicine. The advantages of minimally invasive surgery include better intra-operative visualization, reduced postoperative pain, reduced scar formation and increased postoperative mobility. Therefore, it is reasonable to expect that the application of this will continue to expand. Small animal reproduction, a field within the broad discipline of veterinary medicine, has already recognized and begun to reap the benefits of endoscopic surgery. Herein, we retrospectively review the most recent successful novel applications of endoscopic surgery in the small animal reproduction system to provide small animal reproductive surgeons with important knowledge to help improve their own veterinarian medical practice. © 2016 Blackwell Verlag GmbH.
DEFF Research Database (Denmark)
Tamke, Martin; Evers, Henrik Leander; Clausen Nørgaard, Esben
2016-01-01
Filigree Robotics experiments with the combination of traditional ceramic craft with robotic fabrication in order to generate a new narrative of fine three-dimensional ceramic ornament for architecture.......Filigree Robotics experiments with the combination of traditional ceramic craft with robotic fabrication in order to generate a new narrative of fine three-dimensional ceramic ornament for architecture....
Regression of gastric malt-lymphoma under specific therapy may be predict by endoscopic ultrasound.
Gheorghe, Cristian; Băncilă, Ion; Stoia, Răzvan; Gheorghe, Liana; Becheanu, Gabriel; Dobre, Camelia; Brescan, Raluca
2004-06-01
Mucosa-associated lymphoid tissue (MALT) lymphomas represent a relatively new described class of rare lymphomas, characterized by an indolent course and favourable outcome with specific therapy. Gastric MALT lymphomas are associated with chronic Helicobacter pylori (HP) infection. We report the case of a 67 year old man admitted for an 8-month history of epigastric pain, anorexia and progressive weight loss. He was diagnosed with low-grade primary gastric MALT lymphoma by endoscopy, histopathological examination of gastric mucosa (light microscopy and immunohistochemistry) and endoscopic ultrasonography (EUS). The patient received a 2-week course of anti-HP therapy and chemotherapy with Chlorambucil 0.1 mg/kg/day was started. During the follow-up, continuous improvement of clinical status, endoscopic and EUS appearance was noted. We conclude that, facing the trend toward nonsurgical treatment modalities for primary gastric lymphoma, EUS appears an important tool for staging the disease and defining cases suitable for anti-HP, radio- and chemotherapy, as well as for the detection of local recurrence.
Update on endoscopic pancreatic function testing
Institute of Scientific and Technical Information of China (English)
Tyler Stevens; Mansour A Parsi
2011-01-01
Hormone-stimulated pancreatic function tests (PFTs) are considered the gold standard for measuring pancreatic exocrine function. PFTs involve the administration of intravenous secretin or cholecystokinin, followed by collection and analysis of pancreatic secretions. Because exocrine function may decline in the earliest phase of pancreatic fibrosis, PFTs are considered accurate for diagnosing chronic pancreatitis. Unfortunately, these potentially valuable tests are infrequently performed except at specialized centers, because they are time consuming and complicated. To overcome these limitations, endoscopic PFT methods have been developed which include aspiration of pancreatic secretions through the suction channel of the endoscope. The secretin endoscopic pancreatic function test (ePFT) involves collection of duodenal aspirates at 15, 30, 45 and 60 min after secretin stimulation. A bicarbonate concentration greater than 80 mmol/L in any of the samples is considered a normal result. The secretin ePFT has demonstrated good sensitivity and specificity compared with various reference standards, including the "Dreiling tube" secretin PFT, endoscopic ultrasound, and surgical histology. Furthermore, a standard autoanalyzer can be used for bicarbonate analysis, which allows the secretin ePFT to be performed at any hospital. The secretin ePFT may complement imaging tests like endoscopic ultrasound (EUS) in the diagnosis of early chronic pancreatitis.This paper will review the literature validating the use of ePFT in the diagnosis of exocrine insufficiency and chronic pancreatitis. Newer developments will also be discussed, including the feasibility of combined EUS/ePFT, the use of cholecystokinin alone or in combination with secretin, and the discovery of new protein and lipid pancreatic juice biomarkers which may complement traditionalfluid analysis.
Endoscopic sleeve gastroplasty: the learning curve.
Hill, Christine; El Zein, Mohamad; Agnihotri, Abhishek; Dunlap, Margo; Chang, Angela; Agrawal, Alison; Barola, Sindhu; Ngamruengphong, Saowanee; Chen, Yen-I; Kalloo, Anthony N; Khashab, Mouen A; Kumbhari, Vivek
2017-09-01
Endoscopic sleeve gastroplasty (ESG) is gaining traction as a minimally invasive bariatric treatment. Concern that the learning curve may be slow, even among those proficient in endoscopic suturing, is a barrier to widespread implementation of the procedure. Therefore, we aimed to define the learning curve for ESG in a single endoscopist experienced in endoscopic suturing who participated in a 1-day ESG training program. Consecutive patients who underwent ESG between February 2016 and November 2016 were included. The performing endoscopist, who is proficient in endoscopic suturing for non-ESG procedures, participated in a 1-day ESG training session before offering ESG to patients. The outcome measurements were length of procedure (LOP) and number of plications per procedure. Nonlinear regression was used to determine the learning plateau and calculate the learning rate. Twenty-one consecutive patients (8 males), with mean age 47.7 ± 11.2 years and mean body mass index 41.8 ± 8.5 kg/m 2 underwent ESG. LOP decreased significantly across consecutive procedures, with a learning plateau at 101.5 minutes and a learning rate of 7 cases ( P = 0.04). The number of plications per procedure also decreased significantly across consecutive procedures, with a plateau at 8 sutures and a learning rate of 9 cases ( P < 0.001). Further, the average time per plication decreased significantly with consecutive procedures, reaching a plateau at 9 procedures ( P < 0.001). Endoscopists experienced in endoscopic suturing are expected to achieve a reduction in LOP and number of plications per procedure in successive cases, with progress plateauing at 7 and 9 cases, respectively.
Hydraulic bilateral construction robot; Yuatsushiki bilateral kensetsu robot
Energy Technology Data Exchange (ETDEWEB)
Maehata, K.; Mori, N. [Kayaba Industry Co. Ltd., Tokyo (Japan)
1999-05-15
Concerning a hydraulic bilateral construction robot, its system constitution, structures and functions of important components, and the results of some tests are explained, and the researches conducted at Gifu University are described. The construction robot in this report is a servo controlled system of a version developed from the mini-shovel now available in the market. It is equipped, in addition to an electrohydraulic servo control system, with various sensors for detecting the robot attitude, vibration, and load state, and with a camera for visualizing the surrounding landscape. It is also provided with a bilateral joy stick which is a remote control actuator capable of working sensation feedback and with a rocking unit that creates robot movements of rolling, pitching, and heaving. The construction robot discussed here, with output increased and response faster thanks to the employment of a hydraulic driving system for the aim of building a robot system superior in performance to the conventional model designed primarily for heavy duty, proves after tests to be a highly sophisticated remotely controlled robot control system. (NEDO)
International Nuclear Information System (INIS)
Guillen, J.A.
1998-07-01
This paper describes the calculation method to assess dose and energy using the film holder from NRPB/AERE and the film Agfa Monitoring 2/10. Also includes all the steps since preparing the standard curve, fitting of calibration curve, dose assesment, description of filtration of the film holder and the form of the calibration curve
International Nuclear Information System (INIS)
Benton, O.
1984-01-01
Robotics education courses are rapidly spreading throughout the nation's colleges and universities. Engineering schools are offering robotics courses as part of their mechanical or manufacturing engineering degree program. Two year colleges are developing an Associate Degree in robotics. In addition to regular courses, colleges are offering seminars in robotics and related fields. These seminars draw excellent participation at costs running up to $200 per day for each participant. The last one drew 275 people from Texas to Virginia. Seminars are also offered by trade associations, private consulting firms, and robot vendors. IBM, for example, has the Robotic Assembly Institute in Boca Raton and charges about $1,000 per week for course. This is basically for owners of IBM robots. Education (and training) can be as short as one day or as long as two years. Here is the educational pattern that is developing now
Miniature, minimally invasive, tunable endoscope for investigation of the middle ear.
Pawlowski, Michal E; Shrestha, Sebina; Park, Jesung; Applegate, Brian E; Oghalai, John S; Tkaczyk, Tomasz S
2015-06-01
We demonstrate a miniature, tunable, minimally invasive endoscope for diagnosis of the auditory system. The probe is designed to sharply image anatomical details of the middle ear without the need for physically adjusting the position of the distal end of the endoscope. This is achieved through the addition of an electrowetted, tunable, electronically-controlled lens to the optical train. Morphological imaging is enabled by scanning light emanating from an optical coherence tomography system. System performance was demonstrated by imaging part of the ossicular chain and wall of the middle ear cavity of a normal mouse. During the experiment, we electronically moved the plane of best focus from the incudo-stapedial joint to the stapedial artery. Repositioning the object plane allowed us to image anatomical details of the middle ear beyond the depth of field of a static optical system. We also demonstrated for the first time to our best knowledge, that an optical system with an electrowetted, tunable lens may be successfully employed to measure sound-induced vibrations within the auditory system by measuring the vibratory amplitude of the tympanic membrane in a normal mouse in response to pure tone stimuli.
Endoscopic removal of a dislocated tomour prothesis from the stomach
International Nuclear Information System (INIS)
Rueckauer, K.; Dinkel, E.
1985-01-01
Endoscopic pertubation of oesophagogustric neoplasms is an established method of palliative treatment. The dislocated plastic prosthesis may be removed with difficulties from the stomach endoscopically. A simple technique for endoscopic removal of the prosthesis is described. The tube can be precisely centred within the oesophageal lumen by use of an intestinal decompression tube and additional guidance by the endoscopic retraction forceps. Thus gross damge of the exophytic tumor tissue with bleeding or perforation sequelae can be avoided. Injury to the patient does not exceed that caused by an ordinary gastroscopy. (orig.) [de
International Nuclear Information System (INIS)
Riveron Quevedo, Kelly; Irsula Ballaga, Vladimir; Gonzalez Ulloa, Lianne; Deborah LLorca, Armando
2012-01-01
The case report of a 30 year-old presumably healthy patient, who attended the Gastroenterology Department from 'Dr Juan Bruno Zayas Alfonso' Teaching General Hospital in Santiago de Cuba, and suffering from biliary cholic, ictero, choluria, nausea, vomit and loss of appetite is presented. The complementary examinations confirmed the choledocolitiasis and cholelitiasis diagnosis, reason why it was necessary to carry out a endoscopic retrograde cholangiopancreatography, endoscopic esphinterotomy and ambulatory laparoscopic cholecystectomy, in a single anesthetic injection. The postoperative clinical course was favorable and she was discharged without complications 24 hours before the intervention
Coblation-assisted endonasal endoscopic resection of juvenile nasopharyngeal angiofibroma.
Ye, L; Zhou, X; Li, J; Jin, J
2011-09-01
Juvenile nasopharyngeal angiofibroma may be successfully resected using endoscopic techniques. However, the use of coblation technology for such resection has not been described. This study aimed to document cases of Fisch class I juvenile nasopharyngeal angiofibroma with limited nasopharyngeal and nasal cavity extension, which were completely resected using an endoscopic coblation technique. We retrospectively studied 23 patients with juvenile nasopharyngeal angiofibroma who underwent resection with either traditional endoscopic instruments (n = 12) or coblation (n = 11). Intra-operative blood loss and overall operative time were recorded. The mean tumour resection time for coblation and traditional endoscopic instruments was 87 and 136 minutes, respectively (t = 9.962, p angiofibroma (Fisch class I), with good surgical margins and minimal blood loss.
Endoscope disinfection and its pitfalls--requirement for retrograde surveillance cultures.
Buss, A J; Been, M H; Borgers, R P; Stokroos, I; Melchers, W J; Peters, F T; Limburg, A J; Degener, J E
2008-04-01
Several endoscopy-related outbreaks of infection have been reported in recent years. For early recognition of inadequate disinfection of endoscopes we designed a microbiological surveillance system to evaluate the efficacy of the cleaning and disinfection procedure, and to trace disinfection problems to individual endoscopes or washer-disinfectors. Our surveillance protocol included anterograde and retrograde sampling, a decision algorithm, genetic fingerprinting, and scanning electron microscopy. Over a period of 29 months we found an increasing number of patient-ready endoscopes testing positive for Candida species other than albicans, especially C. parapsilosis. These yeasts were also isolated from the washer-disinfectors. The number of positive tests for Candida species varied from 1 out of 21 to 14 out of 27 samples from nine frequently used endoscopes. The number of colony-forming units per milliliter ranged from 1 - 10 to 3000 for endoscopes and 0.002 to 0.06 for the washer disinfectors. DNA fingerprinting was not able to discriminate different strains within C. parapsilosis. Our protocol was able to detect a structural problem in the endoscope disinfection process. Retrograde sampling was crucial for this purpose, because it has much higher sensitivity than anterograde sampling. Endoscopes with damaged working channels are probably the source of the contamination problem with Candida species.
Untethered Recyclable Tubular Actuators with Versatile Locomotion for Soft Continuum Robots.
Qian, Xiaojie; Chen, Qiaomei; Yang, Yang; Xu, Yanshuang; Li, Zhen; Wang, Zhenhua; Wu, Yahe; Wei, Yen; Ji, Yan
2018-05-27
Stimuli-responsive materials offer a distinguished platform to build tether-free compact soft robots, which can combine sensing and actuation without a linked power supply. In the past, tubular soft robots have to be made by multiple components with various internal channels or complex cavities assembled together. Moreover, robust processing, complex locomotion, simple structure, and easy recyclability represent major challenges in this area. Here, it is shown that those challenges can be tackled by liquid crystalline elastomers with allyl sulfide functional groups. The light-controlled exchange reaction between allyl sulfide groups allows flexible processing of tubular soft robots/actuators, which does not need any assisting materials. Complex locomotion demonstrated here includes reversible simultaneous bending and elongation; reversible diameter expansion; and omnidirectional bending via remote infrared light control. Different modes of actuation can be programmed into the same tube without the routine assembly of multiple tubes as used in the past. In addition, the exchange reaction also makes it possible to use the same single tube repeatedly to perform different functions by erasing and reprogramming. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
DEFF Research Database (Denmark)
Jochum, Elizabeth Ann; Putnam, Lance Jonathan
This paper considers art-based research practice in robotics through a discussion of our course and relevant research projects in autonomous art. The undergraduate course integrates basic concepts of computer science, robotic art, live performance and aesthetic theory. Through practice...... in robotics research (such as aesthetics, culture and perception), we believe robot aesthetics is an important area for research in contemporary aesthetics....
Early GRB optical and infrared afterglow observations with the 2-m robotic Liverpool Telescope
International Nuclear Information System (INIS)
Gomboc, A.; Ljubljana Univ., Ljubljana; Mundell, C.G.; Guidorzi, C.
2005-01-01
We present the first optical observations of a Gamma Ray Burst IGRB) afterglow using the 2-m robotic Liverpool Telescope (LT), which is owned and operated by Liverpool John Moores University and situated on La Palma. We briefly discuss the capabilities of LT and its suitability for rapid follow-up observations of early optical and infrared GRB light curves. In particular, the combination of aperture, site, instrumentation and rapid response (robotic over-ride mode aided by telescope's rapid slew and fully-opening enclosure) makes the LT ideal for investigating the nature of short bursts, optically-dark bursts, and GRB blast-wave physics in general. We briefly describe the LT's key position in the RoboNet-1.0 network of robotic telescopes. We present the LT observations of GRB041006 and use its gamma-ray properties to predict the time of the break in optical light curve, a prediction consistent with the observations