WorldWideScience

Sample records for lif tld-100 irradiated

  1. Thermoluminescence of pure LiF and Lif (TLD-100) irradiated at room temperature

    International Nuclear Information System (INIS)

    Sagastibelza Chivite, F.

    1980-01-01

    The thermoluminescence of pure LiF and LiF (TLD-100) crystals irradiated at room temperature with x - or gamma-rays has been studied up to 460 degree centigree. For most of the glow peaks found the kinetics, preexponential factors and activation energies have been determined. These parameters have been obtained by means of the isothermal method. The study of the thermal annealing of the radiation induced F and Z centres has allow to show that there is a correlation among the glow peaks and the annealing stages of these centres. It is concluded that the F and Z - centres play the role of recombination centres for halogen interstitial atom thermally released from traps. Light emission occurs in this recombination. (Author) 120 refs

  2. Thermoluminescence of pure LiF and Lif (TLD-100) irradiated at room temperature; Termoluminiscencia en LiF puro y LiF dosimetrico (TLD-100), irradiados a temperatura ambiente

    Energy Technology Data Exchange (ETDEWEB)

    Sagastibelza Chivite, F

    1980-07-01

    The thermoluminescence of pure LiF and LiF (TLD-100) crystals irradiated at room temperature with x - or gamma-rays has been studied up to 460 degree centigree. For most of the glow peaks found the kinetics, preexponential factors and activation energies have been determined. These parameters have been obtained by means of the isothermal method. The study of the thermal annealing of the radiation induced F and Z centres has allow to show that there is a correlation among the glow peaks and the annealing stages of these centres. It is concluded that the F and Z - centres play the role of recombination centres for halogen interstitial atom thermally released from traps. Light emission occurs in this recombination. (Author) 120 refs.

  3. Comparative study of thermoluminescent properties of LiF: Mg, Cu, P, LiF: Mg, Ti and TLD-100 irradiated with X-rays

    International Nuclear Information System (INIS)

    Azorin, J.; Rivera, T.; Gonzalez, P.; Ortega, X.; Ginjaume, M.

    2000-01-01

    The thermoluminescent properties (Tl) of LiF: Mg, Cu, P, and LiF: Mg, Ti, were investigated both developed in Mexico and comparing them with the properties of TLD-100 when they are exposure to X-rays. The Tl curve of LiF: Mg, Cu, P exhibited two peaks at 200 and 300 Centigrade. Its response Tl in function of dose resulted linear in the interval of 0.5 Gy until 5 Gy and its sensitivity to X-ray was around 25 times greater that of the TLD-100. Also it was measured the Tl response of the three materials in function of photon energy. The results showed that LiF: Mg, Cu, P has potential to be used as X-ray dosemeter. (Author)

  4. Comparison of LiF (TLD-100 and TLD-100H) detectors for extremity monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Freire, L. [Departamento de Proteccao Radiologica e Seguranca Nuclear, Instituto Tecnologico e Nuclear, E.N. 10, 2683-953 Sacavem (Portugal); Laboratorio de Medicina Nuclear, Lda, Atomedical, Rua Helena Felix, 11D, 1600-121 Lisboa (Portugal); Calado, A.; Cardoso, J.V.; Santos, L.M. [Departamento de Proteccao Radiologica e Seguranca Nuclear, Instituto Tecnologico e Nuclear, E.N. 10, 2683-953 Sacavem (Portugal); Alves, J.G. [Departamento de Proteccao Radiologica e Seguranca Nuclear, Instituto Tecnologico e Nuclear, E.N. 10, 2683-953 Sacavem (Portugal)], E-mail: jgalves@itn.pt

    2008-02-15

    In this work the results aimed at assessing the performance of two types of LiF detectors, TLD-100 and TLD-100H, used in the context of extremity dosimetry are presented. Each detector variety was studied for reproducibility, batch homogeneity, residual dose, linearity and energy dependence using, when appropriate, the {sup 90}Sr/{sup 90}Y radiation source built-in one of the Harshaw 6600 readers, the ISO narrow X-ray beams of N30, N40, N60, N80, N100 and N120 or the gamma radiations of {sup 137}Cs and {sup 60}Co. Two calibration energies (N120 and {sup 137}Cs) were also used. The reproducibility and linearity results indicate that both LiF:Mg,Ti and LiF:Mg,Cu,P performed equally well. However, LiF:Mg,Cu,P presents a higher residual signal. In terms of energy dependence, LiF:Mg,Cu,P shows less variation than LiF:Mg,Ti particularly when N120 is used as calibration radiation. This seems to be a more realistic setup since the energy of the most frequently used radioisotopes in Nuclear Medicine departments with single photon emission computed tomography (SPECT) use gamma radiation energies closer to N120 than to {sup 137}Cs.

  5. Investigation of LiF, Mg and Ti (TLD-100 Reproducibility

    Directory of Open Access Journals (Sweden)

    Sadeghi M.

    2015-12-01

    Full Text Available LiF, Mg and Ti cubical TLD chips (known as TLD-100 are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and the values of Element Correction Coefficient (ECC were obtained 4 times by irradiating them to doses of 81 mGy (two times, 162mGy and 40.5mGy. Results of this study indicate that the average reproducibility of ECC calculation for 40 TLDs is 1.5%, while these values for all chips do not exceed 5%.

  6. Investigation of LiF, Mg and Ti (TLD-100) Reproducibility.

    Science.gov (United States)

    Sadeghi, M; Sina, S; Faghihi, R

    2015-12-01

    LiF, Mg and Ti cubical TLD chips (known as TLD-100) are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy) with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and the values of Element Correction Coefficient (ECC) were obtained 4 times by irradiating them to doses of 81 mGy (two times), 162mGy and 40.5mGy. Results of this study indicate that the average reproducibility of ECC calculation for 40 TLDs is 1.5%, while these values for all chips do not exceed 5%.

  7. Response of TLD-100 LiF dosimeters for X-rays of low energies

    International Nuclear Information System (INIS)

    Bonzi, E. V.; Mainardi, R. T.

    2011-10-01

    In diverse practical applications as the existent in radiological clinics, industrial facilities and research laboratories, the solid state dosimeters are used for the measure of the different types of ionizing radiations. At the present time dosimeters are manufactured with different types of materials that present thermoluminescent properties, to the effects of determining the absorbed radiation dose. Under these conditions, the radiation dose is determined integrated in all the range of energies of the beam of X-rays, since it assumes that the response of these dosimeters is lineal with the energy of the photons or radiant particles. Because interest exists in advancing in the development of a determination method in the way of the X-rays spectrum emitted by a tube of those used in diagnostic or therapy, we have measured the response of TLD-100 LiF dosimeters for low energies, minor at 60 keV, for a several group of these dosimeters. (Author)

  8. Effects of annealing on the sensitivity of LiF TLD-100 after repeated use for low dose measurements

    International Nuclear Information System (INIS)

    Ogunleye, O.T.; Richmond, R.G.

    1987-01-01

    The changes in sensitivity of LiF TLD-100 extruded ribbons subjected to repeated use up to 100 times were investigated. Three different annealing regimes were compared. The dosemeters were annealed at 400 0 C followed by (i) a slow or (ii) fast cooling to room temperature or (iii) utilising a 20 s readout process in the reader without a high temperature annealing at 400 0 C. Each of the three groups consisted of two sets of 20 chips each, with one set receiving 500 μ Gy of 90 Sr beta radiation and the other unirradiated. Sensitivity evaluations were performed every five cycles through the first 50 cycles, and on each tenth cycle thereafter. On the average, the fast cooled group maintained their integrity best, while a maximum variation in sensitivity of about 15% was observed in the irradiated set of the slowly cooled group. A permanent increase in sensitivity of at least 10% was observed for the set of dosemeters receiving radiation without annealing. Glow curve analyses showed an increase in the ratio of peaks 4 and 5 with repeated use of this group. (author)

  9. Obtention of thermoluminescent efficiencies by means of irradiation of TLD-100 dosemeters with proton beams helium and carbon

    International Nuclear Information System (INIS)

    Avila, O.; Rodriguez V, M.; Aviles, P.; Gamboa de Buen, I.; Buenfil, A.E.; Ruiz T, C.; Brandan, M.E.

    2002-01-01

    In this work, the advances of a serial of measurements of relative efficiency thermoluminescent of heavy charged particles (PCP) with respect to gamma radiation for TLD-100, dosemeters of LiF: Mg,Ti manufactured by the Harshaw-Bicron company are reported. The PCP are essentials in the implementation of dosimetry associated with medical applications. The measurements before gamma radiation were carrying out using the Vickrad irradiator of the National Institute of Nuclear Research at dose of 1.663 Gy. The measures which are reported about protons, helium and carbon were realized using the Pelletron accelerator of the Physics Institute of the UNAM. (Author)

  10. Environmental dosimetry system based on LiF : Mg, Ti (TLD-100)

    International Nuclear Information System (INIS)

    Saez Vergara, J.C.

    1990-01-01

    The report presents the various tests carried out to the characterize a thermoluminescence environmental dosimetry systems, using the phosphor LiF:mg,Ti (TLD-100) in chip form. The holder has been specifically designed in order to obtain simplicity in the operation and to assure correct measurements in terms of the new operational quantities in radiation protection (ICRU-1985). Some topics in TLD Environmental Monitoring are discussed (Dark Current, Reference Light, Zero Reading, Free-in-Air or Phantom Calibration, Fading Correction, Transit Dose, etc.), and the proposed solutions are exposed. The tests performed have been designed to conform with the different existing international Standards and Recommendations (ANSI : N545-1975; IEC: Draft 45B-1987, ISO : DP 8034-19849. The data from an European Interlaboratory Programm (EUR-8932) have been used to evaluate the performance : the TLD System presented is among the best systems using TLD-100. The results obtained in the characterization (linearity, repeatability, detection threshold, residue, angular response, stability of stored information, etc.) show the optimum performance of this dosimetric system in its application to environmental gamma dose monitoring. Based on these results, two operational procedures have been developed for the application of this Dosimetric System, specially in Quality Assurance Monitoring Programs around Nuclear Plants in Spain. (author)

  11. Response of TLD-100 LiF dosimeters for X-rays of low energies; Respuesta de dosimetros de TLD-100 de LiF para rayos X de bajas energias

    Energy Technology Data Exchange (ETDEWEB)

    Bonzi, E. V.; Mainardi, R. T. [Universidad Nacional de Cordoba, Facultad de Matematica, Astronomia y Fisica, Av. Haya de la Torre y Av. Medina Allende s/n, Ciudad Universitaria, X5016LEA Cordoba (Argentina)

    2011-10-15

    In diverse practical applications as the existent in radiological clinics, industrial facilities and research laboratories, the solid state dosimeters are used for the measure of the different types of ionizing radiations. At the present time dosimeters are manufactured with different types of materials that present thermoluminescent properties, to the effects of determining the absorbed radiation dose. Under these conditions, the radiation dose is determined integrated in all the range of energies of the beam of X-rays, since it assumes that the response of these dosimeters is lineal with the energy of the photons or radiant particles. Because interest exists in advancing in the development of a determination method in the way of the X-rays spectrum emitted by a tube of those used in diagnostic or therapy, we have measured the response of TLD-100 LiF dosimeters for low energies, minor at 60 keV, for a several group of these dosimeters. (Author)

  12. Measure of the attenuation curve of a beam of X-rays with TLD-100 dosimeters of LiF; Medicion de la curva de atenuacion de un haz de rayos X con dosimetros TLD-100 de LiF

    Energy Technology Data Exchange (ETDEWEB)

    Bonzi, E. V.; Mainardi, R. T. [Universidad Nacional de Cordoba, Facultad de Matematica, Astronomia y Fisica, Av. Haya de la Torre y Av. Medina Allende s/n, Ciudad Universitaria, Cordoba (Argentina); Germanier, A. [Ministerio de Ciencia y Tecnologia, Ceprocor, Unidad de Estudios Fisicos, Alvarez de Arenas 230, X5004AAP Barrio Juniors, Cordoba (Argentina); Delgado, V. [Universidad Complutense de Madrid, Departamento de Fisica Medica, Ciudad Universitaria, 28040 Madrid (Spain)

    2011-10-15

    The attenuation curve of a beam of X-rays represents the beam intensity in function of the attenuator thickness interposed between the source and the detector. To know with the major possible precision the attenuation curve is indispensable in procedures of spectral reconstruction. Their periodic measuring also offers valuable information on the correct operation of a tube of X-rays, diagnostic or therapy, when not have a specific detector for that activity. In this work was measured the attenuation curve of a tube of X-rays operated to 50 kV and 0.5 ma, using existent elements in any diagnostic or therapy laboratory with radiations. In the measures commercial aluminum foil was used, bent until 24 times and thermoluminescent dosimeters TLD 100 - LiF. Also, for comparison, was measured this attenuation curve with an ionization chamber brand Capintec model 192. Was determined by X-rays fluorescence the composition of the aluminium foil, since the present elements in the alloy can to affect the form of the attenuation curve. It is interesting to observe that these elements are in very low proportion (ppm) that they do not alter the attenuation capacity of the pure aluminium. Finally in a precision balance we weigh a big piece (30 cm x 100 cm) of aluminium foil and we obtained the thickness in g/c m2. It is possible to obtain attenuation curves of a beam of X-rays, with a high precision procedure and reproducibility. The use of TLD-100 dosimeters of LiF or similar makes that this activity was also quick and simple. (Author)

  13. Measure of the attenuation curve of a beam of X-rays with TLD-100 dosimeters of LiF

    International Nuclear Information System (INIS)

    Bonzi, E. V.; Mainardi, R. T.; Germanier, A.; Delgado, V.

    2011-10-01

    The attenuation curve of a beam of X-rays represents the beam intensity in function of the attenuator thickness interposed between the source and the detector. To know with the major possible precision the attenuation curve is indispensable in procedures of spectral reconstruction. Their periodic measuring also offers valuable information on the correct operation of a tube of X-rays, diagnostic or therapy, when not have a specific detector for that activity. In this work was measured the attenuation curve of a tube of X-rays operated to 50 kV and 0.5 ma, using existent elements in any diagnostic or therapy laboratory with radiations. In the measures commercial aluminum foil was used, bent until 24 times and thermoluminescent dosimeters TLD 100 - LiF. Also, for comparison, was measured this attenuation curve with an ionization chamber brand Capintec model 192. Was determined by X-rays fluorescence the composition of the aluminium foil, since the present elements in the alloy can to affect the form of the attenuation curve. It is interesting to observe that these elements are in very low proportion (ppm) that they do not alter the attenuation capacity of the pure aluminium. Finally in a precision balance we weigh a big piece (30 cm x 100 cm) of aluminium foil and we obtained the thickness in g/c m2. It is possible to obtain attenuation curves of a beam of X-rays, with a high precision procedure and reproducibility. The use of TLD-100 dosimeters of LiF or similar makes that this activity was also quick and simple. (Author)

  14. On the determination of the post-irradiation time from the glow curve of TLD-100

    International Nuclear Information System (INIS)

    Weinstein, M.; German, U.; Dubinsky, S.; Alfassi, Z.B.

    2003-01-01

    The ratio of peak 3 to the sum of peaks 4 + 5 in TLD-100 was measured for various pre-irradiation and post-irradiation time periods, under conditions characteristic of routine personal dosimetry. It was confirmed that the value of this ratio depends only on the elapsed time between the prior readout and the present one, independent of the moment when the irradiation took place during the total time interval (storage time). This effect indicates that fading of peak 3 seems to be due mainly to changes in the unoccupied traps, and not to decay of trapped charges, being almost independent of the presence of electrons or holes in the traps. This observation leads to the conclusion that the suggestions in the past to use the decay of peak 3 in TLD-100 for the measurement of the elapsed time between irradiation and readout may have been wrong. On the other hand, the decay of peak 2 can be used to measure the elapsed time from irradiation, since the rate of decay is different when related to pre-irradiation and post-irradiation times, indicating a much higher decay rate of the trapped charges (Randall-Wilkins decay). However, because of the fast decay rate of peak 2, its use for determination of the elapsed time since irradiation is of little practical significance. (author)

  15. Dosimetric analysis using glasses TLD-100 Lif; Mg; TI for the optimization of the quality control programs in radio surgery stereo tactic

    International Nuclear Information System (INIS)

    Maldonado, J. C; Plazas, M. C.; Dussan, R.; Conrado, Z.; Pena, G.; Jimenez, E.; Hakim, F.; Bermudez, S.

    2001-01-01

    The conditions of Stereo Tactic Radio Surgery treatments are simulated by means of the use of thermo luminescent glasses TLD-100 LiF; Mg; Ti placed in mannequins, to demonstrate that the doses received by the patients, either in the fractioned or in the mono fractioned techniques, are over the 500cGy, making urgent the use of a reliable dosimetric method [es

  16. Thermoluminescent response of dosemeters TLD-100 exposed to distinct baker protocols, irradiation and reading

    International Nuclear Information System (INIS)

    Estrada E, D.

    2002-01-01

    The interest that motivated the realization of this work is the opposing discrepancy among the values of the efficiency thermoluminescent of heavy charged particles (PCP) regarding gamma radiation (η PCP , γ) reported in different works and gathered recently for Horowitz (Ho 01). The measures of relative thermoluminescent efficiency have importance in relation to the dosimetry associated to medical therapy with heavy charged particle. The measurement of η PCP , γ depends of multiple experimental factors. To understand this dependence it was quantified the effect of using different procedures experimental in the estimate of the relative thermoluminescent efficiency of dosemeters TLD-100 (LiF: Ti; Mg) for protons of 3 MeV regarding gamma rays of 60 Co (η PCP , γ), varying the lot, the presentation, the one baked and the team reader. When was used the same global procedure values they were obtained for (η PCP , γ) inside the interval [0.30, 0.58] for the peak 5 and [0.35, 0.76] for the total thermoluminescent signal (Tl). At the use different equipment, baked and lot are obtained maximum differences of 30%, 12% and 6% respectively in the values of (η PCP , γ) for the peak 5, and 25%, 28% and 7% for the total Tl signal. The changes more significant of 36% and 44% for peak 5 and total signal respectively are obtained when changing the presentation of the dosemeter. As a complementary investigation it was studied the distribution of the Tl signal of each peak in the deconvolution of the curve of brightness with regard to the total signal in exposed dosemeters to high fluence of protons (1x10 10 p/cm 2 ) varying the experimental protocol. It was found that the distribution of the Tl signal has a difference of the order of 5% when changing the used reading team. It was observed that the contribution of the peak 5 regarding the total signal are preserved when changing baked and that it results to be 8% greater for the presentation in dosemeters of 1 x 1 x 1 mm 3

  17. Environmental effects on TLD 100

    International Nuclear Information System (INIS)

    Lilley, E.; Howard, R.

    1976-01-01

    Reference is made to a recent paper by Dhar et al (Health Phys.; 25:427 (1973)) in which significant differences in the sensitivity of TLD 100 crystals following the same heat treatments in different environments, were reported. Similar work is here reported on TLD 100 at 400 0 C with half the crystals being heat treated in vacuum, irradiated and readout an then annealed in air, irradiated and readout while the other half of the crystals were air annealed and readout before vacuum annealing and readout. In both cases no significant change was detected in contrast to the results of Dhar et al. (U.K.)

  18. Thermoluminescent response of dosemeters TLD-100 exposed to distinct baker protocols, irradiation and reading; Respuesta termoluminiscente de dosimetros TLD-100 sujetos a distintos protocolos de horneado, irradiacion y lectura

    Energy Technology Data Exchange (ETDEWEB)

    Estrada E, D

    2002-07-01

    The interest that motivated the realization of this work is the opposing discrepancy among the values of the efficiency thermoluminescent of heavy charged particles (PCP) regarding gamma radiation ({eta}{sub PCP}, {gamma}) reported in different works and gathered recently for Horowitz (Ho 01). The measures of relative thermoluminescent efficiency have importance in relation to the dosimetry associated to medical therapy with heavy charged particle. The measurement of {eta}{sub PCP}, {gamma} depends of multiple experimental factors. To understand this dependence it was quantified the effect of using different procedures experimental in the estimate of the relative thermoluminescent efficiency of dosemeters TLD-100 (LiF: Ti; Mg) for protons of 3 MeV regarding gamma rays of {sup 60}Co ({eta}{sub PCP}, {gamma}), varying the lot, the presentation, the one baked and the team reader. When was used the same global procedure values they were obtained for ({eta}{sub PCP}, {gamma}) inside the interval [0.30, 0.58] for the peak 5 and [0.35, 0.76] for the total thermoluminescent signal (Tl). At the use different equipment, baked and lot are obtained maximum differences of 30%, 12% and 6% respectively in the values of ({eta}{sub PCP}, {gamma}) for the peak 5, and 25%, 28% and 7% for the total Tl signal. The changes more significant of 36% and 44% for peak 5 and total signal respectively are obtained when changing the presentation of the dosemeter. As a complementary investigation it was studied the distribution of the Tl signal of each peak in the deconvolution of the curve of brightness with regard to the total signal in exposed dosemeters to high fluence of protons (1x10{sup 10} p/cm{sup 2}) varying the experimental protocol. It was found that the distribution of the Tl signal has a difference of the order of 5% when changing the used reading team. It was observed that the contribution of the peak 5 regarding the total signal are preserved when changing baked and that it

  19. Experimental calibration and determination of the relative response for Lif: Mg, Ti(TLD-100) dosemeters at 60Co gamma and 60 kVp X-ray energies

    International Nuclear Information System (INIS)

    Marco, M.L.; Gonzalez, L.; Delgado, V.; Vano, E.; Moran, P.

    1985-01-01

    The thermoluminescence efficiency of LiF: Mg, Ti (TLD-100) dosemeters has been determined for photon beams from 60 Co gamma rays and 60 kVp X-rays. It has been proven that light yield varies as a function of the photon energy. An experiment was performed using an X-ray beam whose spectrum has been determined by an X-ray fluorescence method. This enabled a direct calculation of the absorbed doses in the T1 material for the different operation conditions. These values and the experimental ones from measuring T1 intensities have been used to obtain the efficiency for energy X-ray spectrum. From the above values, the dosemeter T1 response, relative to 60 Co, has been evaluated. (author)

  20. A comparative study of the thermoluminescent response to beta irradiation of CVD diamond and LiF dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Bogani, F. [Florence Univ. (Italy). Dipt. di Energetica; Borchi, E. [Florence Univ. (Italy). Dipt. di Energetica; Bruzzi, M. [Florence Univ. (Italy). Dipt. di Energetica; Leroy, C. [Florence Univ. (Italy). Dipt. di Energetica; Sciortino, S. [Florence Univ. (Italy). Dipt. di Energetica

    1997-04-01

    The thermoluminescent (TL) response of chemical vapour deposited (CVD) diamond films to beta irradiation has been investigated. A numerical curve-fitting procedure, calibrated by means of a set of LiF TLD100 experimental spectra, has been developed to deconvolute the complex structured TL glow curves. The values of the activation energy and of the frequency factor related to each of the TL peaks involved have been determined. The TL response of the CVD diamond films to beta irradiation has been compared with the TL response of a set of LiF TLD100 and TLD700 dosimeters. The results have been discussed and compared in view of an assessment of the efficiency of CVD diamond films in future applications as in vivo dosimeters. (orig.).

  1. A comparative study of the thermoluminescent response to beta irradiation of CVD diamond and LiF dosimeters

    Science.gov (United States)

    Bogani, F.; Borchi, E.; Bruzzi, M.; Leroy, C.; Sciortino, S.

    1997-02-01

    The thermoluminescent (TL) response of Chemical Vapour Deposited (CVD) diamond films to beta irradiation has been investigated. A numerical curve-fitting procedure, calibrated by means of a set of LiF TLD100 experimental spectra, has been developed to deconvolute the complex structured TL glow curves. The values of the activation energy and of the frequency factor related to each of the TL peaks involved have been determined. The TL response of the CVD diamond films to beta irradiation has been compared with the TL response of a set of LiF TLD100 and TLD700 dosimeters. The results have been discussed and compared in view of an assessment of the efficiency of CVD diamond films in future applications as in vivo dosimeters.

  2. A comparative study of the thermoluminescent response to beta irradiation of CVD diamond and LiF dosimeters

    International Nuclear Information System (INIS)

    Bogani, F.; Borchi, E.; Bruzzi, M.; Leroy, C.; Sciortino, S.

    1997-01-01

    The thermoluminescent (TL) response of chemical vapour deposited (CVD) diamond films to beta irradiation has been investigated. A numerical curve-fitting procedure, calibrated by means of a set of LiF TLD100 experimental spectra, has been developed to deconvolute the complex structured TL glow curves. The values of the activation energy and of the frequency factor related to each of the TL peaks involved have been determined. The TL response of the CVD diamond films to beta irradiation has been compared with the TL response of a set of LiF TLD100 and TLD700 dosimeters. The results have been discussed and compared in view of an assessment of the efficiency of CVD diamond films in future applications as in vivo dosimeters. (orig.)

  3. SU-E-T-222: Investigation of Pre and Post Irradiation Fading of the TLD100 Thermoluminescence Dosimetry for Photon Beams

    International Nuclear Information System (INIS)

    Sina, S; Sadeghi, M; Faghihi, R

    2014-01-01

    Purpose: The pre-irradiation and post-irradiation fading of the Thermoluminescense dosimeter signals were investigated in this study. Methods: Two groups of TLD chips with pre-determined ECC values were used in this study. The two groups were divided into 6 series, each composing of 5 TLD chips.The first group was used for pre-irradiation fading. 5 TLDs were exposed to a known amount of radiation from Cs-137 source, and were read out the next day. After seven days, the other 5 TLDs were exposed to the same amount of radiation and were read out after a day. The other series of 5 TLDs were also exposed after 7,19,28, 59, and 90 days, and were read out a day after irradiation. The loss in TLD signal were obtained for all the above cases. The second group, was used for postirradiation fading. All the TLDs of this group were exposed to a known amount of radiation from Cs-137 source. The 6 series composed of 5 TLDs were read out after 1,7,19,28,59, and 90 days. The above-mentioned procedures for obtaining pre-irradiation, and post-irradiation fading were performed for three storage temperatures (25°C, 4°C, and −18°C). Results: According to the results obtained in this study, in case of pre-irradiation fading study, the signal losses after 90 days are 12%, 24%, and 17% for 25°C, 4°C, and −18°C respectively. In case of post-irradiation fading study, the sensitivity losses after 90 days are 25%, 216%, and 20% for 25°C, 4°C, and −18°C respectively. Conclusion: The results indicate that the optimized time between exposing and reading out, and also the optimized time between annealing and exposing is 1 day.The reduction of Storage temperature will reduce the post-irradiation fading, While temperature reduction does not have any effect on pre-irradiation fading

  4. SU-E-T-222: Investigation of Pre and Post Irradiation Fading of the TLD100 Thermoluminescence Dosimetry for Photon Beams

    Energy Technology Data Exchange (ETDEWEB)

    Sina, S [Radiation Research Center, Shiraz University, Shiraz (Iran, Islamic Republic of); Sadeghi, M [Nuclear Engineering department, Shiraz university, Shiraz (Iran, Islamic Republic of); Faghihi, R [Radiation Research Center, Shiraz University, Shiraz (Iran, Islamic Republic of); Nuclear Engineering department, Shiraz university, Shiraz (Iran, Islamic Republic of)

    2014-06-01

    Purpose: The pre-irradiation and post-irradiation fading of the Thermoluminescense dosimeter signals were investigated in this study. Methods: Two groups of TLD chips with pre-determined ECC values were used in this study. The two groups were divided into 6 series, each composing of 5 TLD chips.The first group was used for pre-irradiation fading. 5 TLDs were exposed to a known amount of radiation from Cs-137 source, and were read out the next day. After seven days, the other 5 TLDs were exposed to the same amount of radiation and were read out after a day. The other series of 5 TLDs were also exposed after 7,19,28, 59, and 90 days, and were read out a day after irradiation. The loss in TLD signal were obtained for all the above cases. The second group, was used for postirradiation fading. All the TLDs of this group were exposed to a known amount of radiation from Cs-137 source. The 6 series composed of 5 TLDs were read out after 1,7,19,28,59, and 90 days. The above-mentioned procedures for obtaining pre-irradiation, and post-irradiation fading were performed for three storage temperatures (25°C, 4°C, and −18°C). Results: According to the results obtained in this study, in case of pre-irradiation fading study, the signal losses after 90 days are 12%, 24%, and 17% for 25°C, 4°C, and −18°C respectively. In case of post-irradiation fading study, the sensitivity losses after 90 days are 25%, 216%, and 20% for 25°C, 4°C, and −18°C respectively. Conclusion: The results indicate that the optimized time between exposing and reading out, and also the optimized time between annealing and exposing is 1 day.The reduction of Storage temperature will reduce the post-irradiation fading, While temperature reduction does not have any effect on pre-irradiation fading.

  5. Determination of the TLD-100 physical parameters

    International Nuclear Information System (INIS)

    Paucar J, J.; Picon C, C.

    1998-01-01

    This study was realized in the Physics service at the Radiotherapy Department of the National Institute of Neoplasic Diseases in Lima, Peru, it was determined the activation energy, the kinetic order and the frequency factor of the fifth peak of the TLD-100 thermoluminescent spectra using different algorithms. This was carried out in parallel with the implementation and design of a software and an interface associated with the Tl lecturer which allows a semiautomatic control for a thermoluminescent lecturer process. (Author)

  6. Determination of the TLD-100 physical parameters; Determinacion de parametros fisicos del TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Paucar J, J.; Picon C, C. [Instituto Nacional de Enfermedades Neoplasicas. INEN. Av. Angamos Este 2520, Lima 34 (Peru)

    1998-12-31

    This study was realized in the Physics service at the Radiotherapy Department of the National Institute of Neoplasic Diseases in Lima, Peru, it was determined the activation energy, the kinetic order and the frequency factor of the fifth peak of the TLD-100 thermoluminescent spectra using different algorithms. This was carried out in parallel with the implementation and design of a software and an interface associated with the Tl lecturer which allows a semiautomatic control for a thermoluminescent lecturer process. (Author)

  7. Effect of surface contaminants on the light emission spectrum of LiF TLDs

    International Nuclear Information System (INIS)

    Abhold, M.E.

    1987-01-01

    Recent results show the differences between the light emissions spectra from LiF Thermoluminescent Dosimeters (TLDs) for gamma vs. alpha irradiations to be due to contaminants on the surface of the TLD. The light emission spectrum for thermal neutron irradiations was observed to be identical to that for a Cs-137 gamma irradiation in Harshaw TLD-100. Further experiments with surface treatments on TLD-100 indicate trace contaminants introduced by the standard methanol cleansing rinse in reagent grade methanol to have a substantial effect on the light emission spectrum for Am-241 alpha irradiations

  8. Robust determination of effective atomic numbers for electron interactions with TLD-100 and TLD-100H thermoluminescent dosimeters

    International Nuclear Information System (INIS)

    Taylor, M.L.

    2011-01-01

    Lithium fluoride thermoluminescent dosimeters (TLD) are the most commonly implemented for clinical dosimetry. The small physical magnitude of TLDs makes them attractive for applications such as small field measurement, in vivo dosimetry and measurement of out-of-field doses to critical structures. The most broadly used TLD is TLD-100 (LiF:Mg,Ti) and, for applications requiring higher sensitivity to low-doses, TLD-100H (LiF:Mg,Cu,P) is frequently employed. The radiological properties of these TLDs are therefore of significant interest. For the first time, in this study effective atomic numbers for radiative, collisional and total electron interaction processes are calculated for TLD-100 and TLD-100H dosimeters over the energy range 1 keV-100 MeV. This is undertaken using a robust, energy-dependent method of calculation rather than typical power-law approximations. The influence of dopant concentrations and unwanted impurities is also investigated. The two TLDs exhibit similar effective atomic numbers, ranging from approximately 5.77-6.51. Differences arising from the different dopants are most pronounced in low-energy radiative effects. The TLDs have atomic numbers approximately 1.48-2.06 times that of water. The effective atomic number of TLD-100H is consistently higher than that of TLD-100 over a broad energy range, due to the greater influence of the higher-Z dopants on the electron interaction cross sections. Typical variation in dopant concentration does not significantly influence the effective atomic number. The influence on TLD-100H is comparatively more pronounced than that on TLD-100. Contrariwise, unwanted hydroxide impurities influence TLD-100 more than TLD-100H. The effective atomic number is a key parameter that influences the radiological properties and energy response of TLDs. Although many properties of these TLDs have been studied rigorously, as yet there has been no investigation of their effective atomic numbers for electron interactions. The

  9. TL response of LiF: Mg, Cu, P dosemeters in function of the photon energy

    International Nuclear Information System (INIS)

    Gonzalez, P.R.; Azorin, J.; Furetta, C.

    2005-01-01

    In this work the obtained results of studying the response of dosemeters of LiF: Mg, Cu, P + Ptfe, developed in the ININ, commercial dosemeters GR200A (LiF: Mg, Cu, P) of chinese manufacture and TLD-100 (LiF: Mg, Ti) US are presented, when irradiating them with X rays 16, 24, 34.5, 42, 100 and 145 keV of effective energy, with gamma rays of 662 keV ( 137 Cs) and 1252 keV ( 60 Co). The results are presented in function of the sensitivity that the dosemeters showed normalized to gamma radiation of 60 Co. It was appreciated that the dosemeters more equivalent to the tissue, they were those of LiF: Mg, Cu, P + Ptfe, while the less equivalent ones were the TLD-100. (Author)

  10. Thermoluminescent relative efficiencies of TLD-100 for nitrogen ions respect of gamma radiation; Eficiencias termoluminiscentes relativas de TLD-100 para iones de nitrogeno respecto de radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Concha S, K. [UNAM, Facultad de Ciencias, 04510 Mexico D.F. (Mexico); Avila, O. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Gamboa de Buen, I. [ICN-UNAM, 04510 Mexico D.F. (Mexico); Rodriguez V, M.; Buenfil, A.E.; Ruiz T, C.; Brandan, M.E. [IFUNAM, 04510 Mexico D.F. (Mexico)

    2004-07-01

    The purpose of this work is to measure the thermoluminescent relative efficiency of those TLD-100 dosemeters irradiated with nitrogen ions with respect to the gamma radiation of {sup 60} Co, in function of the linear energy transfer (LET). Two energy of such nitrogen ions were selected that has the same value from LET when impacting in the dosemeters but with E{sub 1} energy (4.8 MeV) and E{sub 2} (9.95 MeV) smaller and greater respectively that the energy of the Bragg peak. (Author)

  11. TL response of LiF: Mg, Cu, P dosemeters in function of the photon energy; Respuesta TL de dosimetros de LiF: Mg, Cu, P en funcion de la energia del foton

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, P.R. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Azorin, J. [UAM-I, 09340 Mexico D.F. (Mexico); Furetta, C. [Universita degli Studi di Roma ' La Sapienza' , Piazzale Aldo Moro 2, 00185 Roma (Italy)

    2005-07-01

    In this work the obtained results of studying the response of dosemeters of LiF: Mg, Cu, P + Ptfe, developed in the ININ, commercial dosemeters GR200A (LiF: Mg, Cu, P) of chinese manufacture and TLD-100 (LiF: Mg, Ti) US are presented, when irradiating them with X rays 16, 24, 34.5, 42, 100 and 145 keV of effective energy, with gamma rays of 662 keV ({sup 137} Cs) and 1252 keV ({sup 60} Co). The results are presented in function of the sensitivity that the dosemeters showed normalized to gamma radiation of {sup 60} Co. It was appreciated that the dosemeters more equivalent to the tissue, they were those of LiF: Mg, Cu, P + Ptfe, while the less equivalent ones were the TLD-100. (Author)

  12. Quality control of the breast cancer treatments on Hdr brachytherapy with TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Torres H, F. [Universidad de Cordoba, Materials and Applied Physics Group, 230002 Monteria, Cordoba (Colombia); De la Espriella V, N. [Universidad de Cordoba, Grupo Avanzado de Materiales y Sistemas Complejos, 230002 Monteria, Cordoba (Colombia); Sanchez C, A., E-mail: franciscotorreshoyos@yahoo.com [Universidad de Cordoba, Departamento de Enfermeria, 230002 Monteria, Cordoba (Colombia)

    2014-07-01

    An anthropomorphic Phantom, a female trunk, was built with a natural bone structure and experimental material coated, glycerin and water-based material called JJT to build soft tissue equivalent to the muscle of human tissue, and a polymer (styrofoam) to build the lung as critical organ to simulate the treatment of breast cancer, with high dose rate brachytherapy (Hdr) and sources of Ir-192. The treatments were planned and calculated for the critical organ: Lung, and injury of 2 cm in diameter in breast with Micro Selectron Hdr system and the software Plato Brachytherapy V 14.1 of the Nucletron (Netherlands) which uses the standard protocol of radiotherapy for brachytherapy treatments. The dose experimentally measured with dosimeters TLD-100 LiF: Mg; Ti, which were previously calibrated, were placed in the same positions and bodies mentioned above, with less than 5% uncertainty. The reading dosimeters was carried out in a Harshaw TLD 4500. The results obtained for calculated treatments, using the standard simulator, and the experimental with TLD-100, show a high concordance, as they are on average a ± 1.1% making process becomes in a quality control of this type of treatments. (Author)

  13. Conductivity of γ-irradiated LiF

    International Nuclear Information System (INIS)

    Guckelsberger, K.

    1974-01-01

    The conductivity of pure monocrystalline LiF, γ-irradiated, was measured in the temperature range 0.3-100 deg K. The F centers produced by irradiation disperse phonons like point defects, the corresponding fluorine atoms on inter-lattice sites appear as clusters of about 10 A diameter, and high irradiation doses (above 10 8 R) give rise to extensive perturbation zones. Each of these 3 defects influences heat conduction in a characteristic temperature range and may thus be analyzed during irradiation and consecutive recovery [fr

  14. Thermoluminescent relative efficiencies of TLD-100 for nitrogen ions respect of gamma radiation

    International Nuclear Information System (INIS)

    Concha S, K.; Avila, O.; Gamboa de Buen, I.; Rodriguez V, M.; Buenfil, A.E.; Ruiz T, C.; Brandan, M.E.

    2004-01-01

    The purpose of this work is to measure the thermoluminescent relative efficiency of those TLD-100 dosemeters irradiated with nitrogen ions with respect to the gamma radiation of 60 Co, in function of the linear energy transfer (LET). Two energy of such nitrogen ions were selected that has the same value from LET when impacting in the dosemeters but with E 1 energy (4.8 MeV) and E 2 (9.95 MeV) smaller and greater respectively that the energy of the Bragg peak. (Author)

  15. Evaluation of LiF:Mg,Ti (TLD-100 for Intraoperative Electron Radiation Therapy Quality Assurance.

    Directory of Open Access Journals (Sweden)

    Raffaele Liuzzi

    Full Text Available Purpose of the present work was to investigate thermoluminescent dosimeters (TLDs response to intraoperative electron radiation therapy (IOERT beams. In an IOERT treatment, a large single radiation dose is delivered with a high dose-per-pulse electron beam (2-12 cGy/pulse during surgery. To verify and to record the delivered dose, in vivo dosimetry is a mandatory procedure for quality assurance. The TLDs feature many advantages such as a small detector size and close tissue equivalence that make them attractive for IOERT as in vivo dosimeters.LiF:Mg,Ti dosimeters (TLD-100 were irradiated with different IOERT electron beam energies (5, 7 and 9 MeV and with a 6 MV conventional photon beam. For each energy, the TLDs were irradiated in the dose range of 0-10 Gy in step of 2 Gy. Regression analysis was performed to establish the response variation of thermoluminescent signals with dose and energy.The TLD-100 dose-response curves were obtained. In the dose range of 0-10 Gy, the calibration curve was confirmed to be linear for the conventional photon beam. In the same dose region, the quadratic model performs better than the linear model when high dose-per-pulse electron beams were used (F test; p<0.05.This study demonstrates that the TLD dose response, for doses ≤10 Gy, has a parabolic behavior in high dose-per-pulse electron beams. TLD-100 can be useful detectors for IOERT patient dosimetry if a proper calibration is provided.

  16. Nanodefect formation in LiF crystals under gamma irradiation

    International Nuclear Information System (INIS)

    Mussaeva, M.A.; Ibragimova, Eh.M.; Kalanov, M.U.; Muminov, M.I.

    2006-01-01

    One studied the spectra of absorption and of photoluminescence, microhardness and performed X-ray structure analysis of gamma-irradiated LiF crystals in a shutdown reactor and in 60 Co source when gamma-radiation dose rate was equal to 7.65 Gy/s. In addition to formation of point and combined radiation defects one detected the presence of the gamma-irradiation induced 28 nm size nanoparticles of LiOH phase in Li sublattice. Formation of defects is shown to occur more efficiently in a shutdown reactor in contrast to 60 Co source [ru

  17. Indoor gamma radiation monitoring In Rawalpindi, Pakistan using TLD100

    International Nuclear Information System (INIS)

    Azam, Sana; Tufail, Muhammad; Sohail, Muhammad

    2008-01-01

    Full text: Natural radioactivity originates from extraterrestrial sources as well as from radioactive elements in earth's crust. The amount of radioactivity varies from place to place and with altitude. The aim of this study was to observe the indoor radiation level in Rawalpindi using TLD. For this purpose LiF:Mg:Ti (TLD100) chips were used. Chips were annealed and then calibrated using different sources and the calibration factor obtained by using Cs137 source was selected for dose estimation. Its value was 0.1403 μGy/TL response. Rawalpindi categorized into six regions. In each region, 5 cemented houses were selected and TLD 100 chips were placed at a distance of 0.5 m from ground the level. Chips were properly covered to protect them from ultraviolet light and moisture and were placed for three months. The average annual indoor dose rate for Rawalpindi was estimated to be 392.105μGy/yr and average dose to be 97.65μGy. Therefore, the effective dose for population of Rawalpindi from indoor gamma radiation was estimated to be 313.68μSv/yr using an indoor occupancy factor of 80%. (author)

  18. Phototransfered thermoluminescence for dose reassessment in LiF:mg,ti , LiF: mg,Cu,p TL detectors

    International Nuclear Information System (INIS)

    Rodriguez Otazo, M.; Baly, L.

    2001-01-01

    Phototransfered Thermoluminescence (PTTL) from LiF:Mg,Ti (TLD-100) and LiF: Mg,Cu,P (GR-200) was studied at different conditions using different sources of UV light for dose reassessment purposes. The TL dosimeters were irradiated with 137Cs in the range 2 mGy to 100 mGy. The convenience of using PTTL for dose reassessment was analyzed

  19. Comparison of the calculated absorbed dose using the Cadplan™ treatment planning software and Tld-100 measurements in an Alderson-Rando phantom for a bronchogenic treatment

    Energy Technology Data Exchange (ETDEWEB)

    Gutiérrez Castillo, J. G., E-mail: jggc59@hotmail.com [Departamento de Física, Hospital de Oncología, IMSS, CMN Siglo XXI, Cuauhtémoc 330 Col. Doctores (Mexico); Álvarez Romero, J. T., E-mail: trinidad.alvarez@inin.gob.mx, E-mail: fisarmandotorres@gmail.com, E-mail: victor.tovar@inin.gob.mx; Calderón, A. Torres, E-mail: trinidad.alvarez@inin.gob.mx, E-mail: fisarmandotorres@gmail.com, E-mail: victor.tovar@inin.gob.mx; M, V. Tovar, E-mail: trinidad.alvarez@inin.gob.mx, E-mail: fisarmandotorres@gmail.com, E-mail: victor.tovar@inin.gob.mx [SSDL, Departamento de Metrología ININ, Salazar, Estado de México 15245 (Mexico)

    2014-11-07

    To verify the accuracy of the absorbed doses D calculated by a TPS Cadplan for a bronchogenic treatment (in an Alderson-Rando phantom) are chosen ten points with the following D's and localizations. Point 1, posterior position on the left edge with 136.4 Gy. Points: 2, 3 and 4 in the left lung with 104.9, 104.3 and 105.8 Gy, respectively; points 5 and 6 at the mediastinum with 192.4 and 173.5 Gy; points 7, 8 and 9 in the right lung with 105.8, 104.2 and 104.7 Gy, and 10 at posterior position on right edge with 143.7 Gy. IAEA type capsules with TLD 100 powder are placed, planned and irradiated. The evaluation of the absorbed dose is carried out a curve of calibration for the LiF response (nC) {sup vs} {sup DW}, to several cavity theories. The traceability for the DW is obtained with a secondary standard calibrated at the NRC (Canada). The dosimetric properties for the materials considered are determined from the Hounsfield numbers reported by the TPS. The stopping power ratios are calculated for nominal spectrum to 6 MV photons. The percent variations among the planned and determined D in all the cases they are < ± 3%.

  20. Characterization of TLD-100 micro-cubes for use in small field dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Peña-Jiménez, Salvador, E-mail: zoid-9861@yahoo.com.mx; Gamboa-deBuen, Isabel, E-mail: gamboa@nucleares.unam.mx [Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, Av. Universidad 3000, 04510 DF (Mexico); Lárraga-Gutiérrez, José Manuel, E-mail: jose.larraga.gtz@gmail.com, E-mail: amanda.garcia.g@gmail.com; García-Garduño, Olivia Amanda, E-mail: jose.larraga.gtz@gmail.com, E-mail: amanda.garcia.g@gmail.com [Laboratorio de Física Médica, Instituto Nacional de Neurología y Neurocirugía Manuel Velasco Suárez, Av. Insurgentes Sur 3877, 14269 DF (Mexico)

    2014-11-07

    At present there are no international regulations for the management of millimeter scale fields and there are no suggestions for a reference detector to perform the characterization and dose determination for unconventional radiation beams (small fields) so that the dosimetry of small fields remains an open research field worldwide because these fields are used in radiotherapy treatments. Sensitivity factors and reproducibility of TLD-100 micro-cubes (1×1×1 mm3) were determinate irradiating the dosimeters with a 6 MV beam in a linear accelerator dedicated to radiosurgery at the Instituto Nacional de Neurología y Neurocirugía (INNN). Thermoluminescent response as a function of dose was determined for doses in water between 0.5 and 3 Gy and two field sizes (2×2 cm2 and 10×10 cm2). It was found that the response is linear over the dose range studied and it does not depend on field size.

  1. Response of TLD-100"T"M microtubes to two RQR3 quality radiation beams

    International Nuclear Information System (INIS)

    Nunes, M.G.; Villani, D.; Almeida, S.B.; Vivolo, V.; Yoriyaz, H.; Louis, G.M.J.

    2016-01-01

    The present work compares the response of TLD-100"T"M microcubes to two RQR 3 diagnostic radiology reference quality radiation beams, defined by IEC-61267 norm, aiming to evaluate the detectability of TLD-100"T"M energy dependence reported in literature within the same reference quality radiation range. TLD-100"T"M microcubes reproducibility is assessed through the response of a second set of TLD-100"T"M microcubes, evaluated in a second thermoluminescence reader, to the RQR 3 diagnostic radiology reference quality radiation beam implemented at the Laboratorio de Calibracao de Instrumentos of IPEN, Sao Paulo, SP, Brazil. The dependence of TLD-100"T"M microcubes TL response was not detectable in these conditions and the reproducibility of the measurements is 90,2%. (author)

  2. Self-shielding factors for TLD-600 and TLD-100 in an isotropic flux of thermal neutrons

    International Nuclear Information System (INIS)

    Horowitz, Y.S.; Dubi, A.; Ben Shahar, B.

    1976-01-01

    The applications of lithium fluoride thermoluminescent dosemeters in mixed n-γ environments, and the dependence of LiF-TL on linear energy transfer are both topics of current interest. Monte Carlo calculations have therefore been carried out to determine the thermal neutron absorption probability (and consequently the self-shielding factor) for an isotropic flux of neutrons impinging on different sized cylindrical samples of LiF TLD-100 and TLD-600. The calculations were performed for cylinders of radius up to 10 cm and heights of 0.1 to 1.5 cm. The Monte Carlo results were found to be significantly different from the analytic calculations for infinitely long cylinders, but, as expected, converged to the same value for (r/h) << 1. (U.K.)

  3. Influence of in vitro irradiation upon LIF production by ConA stimulated mononuclear cells

    International Nuclear Information System (INIS)

    Sandru, G.; Veraguth, P.

    1981-01-01

    Leukocyte migration inhibitory factor (LIF) activity of culture supernatants of in vitro irradiated Concanavalin A (ConA) stimulated lymphocytes was tested by measuring granulocyte migration from clotted plasma droplets placed in flat bottom microplates. The specificity of inhibition was assured by pretreating the assay supernatants with anti-LIF antibodies which abrogated granulocyte migration inhibition but did not impair guinea pig Peritoneal Exudate Cells (PEC) migration inhibition. In vitro irradiation (150-1200 rads) of MNC cultures either before or after ConA stimulation did not impair lymphokine production and sometimes significantly improved the supernatants' LIF activity as compared with that of unirradiated cultures. The existence of radiosensitive suppressor cells regulating LIF production by ConA stimulated mononuclear cells is suggested

  4. Tl response of LiF: Mg, Cu, P + PTFE (Mexico) and GR200A (China) dosemeters

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.; Azorin N, J.; Furetta, C.

    2003-01-01

    TLD-100 was the commercial dosemeter more known since some decades ago. This dosemeter was considered for many research groups as the reference material for developing new Tl materials for ionizing radiation dosimetry. Actually it seems that TLD-100 is going to be replaced by the Chinese material GR200A, as reference material due that this material in addition to be considered as a tissue equivalent material, is 30 to 35 times more sensitive that TLD- 100. Results of the study of the Tl response of LiF: Mg, Cu, P + Ptfe developed at ININ-Mexico, comparing them with those of GR200A are presented. These results showed that the sensitivity (s = Tl intensity/weight x dose) to gamma radiation of the LiF: Mg, Cu, P + Ptfe dosimeters was 4.34 meanwhile that of the commercial dosemeter was 3.41. Detection threshold of the dosemeters studied was 2.22 and 0.52 μGy respectively Repeatability after 10 cycles Irradiation-reading-annealing was ±1.39% and ±1.86% respectively. Both types of dosemeters presented a linear response as a function of gamma radiation in the range from 0.02 mGy and 100 Gy. (Author)

  5. Experimental determination of relative light conversion factors of TLD-100 for protons with energies from 2.0 to 9.0 MeV

    International Nuclear Information System (INIS)

    Schmidt, P.; Fellinger, J.; Henniger, J.; Huebner, K.

    1988-01-01

    The efficiency of thermoluminescent (TL) detectors to heavy charged particles is described by the so-called light conversion factor η. Relative light conversion factors for protons, alphas and heavier recoils are needed for the calculation of the neutron sensitivity of TL detectors. Such light conversion factors can be determined experimentally. In this paper a method is presented for the experimental determination of relative light conversion factors. Using the experimental arrangement described, relative light conversion factors for LiF material (TLD-100) for protons were determined. In LiF the relative main peak (peak V) efficiency is always lower than 1. It increases with increasing proton energy whereas the relative efficiency of the high temperature peak (peak VI) shows an opposite dependence on the proton energy. Relative light conversion factors for peak VI clearly exceed 1. (orig.)

  6. Proposal of a postal system for Ir-192 sources calibration used in high dose rate brachytherapy with LiF:Mn:Ti thermoluminescent dosemeters; Proposta de um sistema postal para a calibracao de fontes de {sup 192} Ir, utilizadas em braquiterapia de alta taxa de dose, com dosimetros termoluminescentes de LiF: Mn: Ti

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, W.S.; Borges, J.C.; Almeida, C.E.V. [Instituto de Radioprotecao e Dosimetria. CNEN Caixa Postal 37750, 22780-160, Rio de Janeiro (Brazil)

    1998-12-31

    A proposal in order to improve the brachytherapy quality control and to allow postal intercomparison of Ir-192 sources used in high dose rate brachytherapy has been presented. The LiF: Mn: Ti (TLD 100) detector has been selected for such purpose. The experimental array and the TLDs irradiation and calibration techniques, at the treatment units, have been specified in the light of more recent methodology of Ir-192 calibration sources. (Author)

  7. Dosimetric evaluation of the response of the TLD-100 dosemeters in the IMRT technique by 'Step and Shoot'

    International Nuclear Information System (INIS)

    Vasquez, J.; Benavides, S.O.

    2005-01-01

    We show the results of the dosimetry response of LiF thermoluminescent crystals: TLD-100, where they were radiated in a linear accelerator Siemens Primus Hl using the Intensity Modulated Radiation Therapy (IMRT) by step and shoot technique. Previous to the crystals calibration and response evaluation, the acceptation procedures recommended by the TG-53 protocol for validation of the technique were carried out. The planning system utilized was the Theraplan Plus 3.8, using the algorithm of Pencil Kernel. The register and verification system was Lantis 5.2. The response curve of dose versus charge was obtained from the readings of the TLD in a Harshaw 3500. The crystals were radiated in a Bench- Marck phantom with doses previously determined by using ionization chambers for square radiation fields, in a beam with a 0.68 TPR20,10 corresponding to 6 MV of energy. We compare the response of these through of radiation of segmented fields in a Anthropomorphic phantom and the calculated doses by the planning system. The results obtained in the crystals response show deviations less than 5 % between the measured dose and the calculated dose in the zones of low gradient. It allows its implementation like routine control of quality by IMRT. (Author)

  8. Verification or treatment planning system of radiotherapy using TLD-100; Verificacion de los sistemas de planificacion de tratamiento de radioterapia empleando TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Pinuela, J., E-mail: jcpinuela@hotmail.co [Hospital Central de Maracay (Venezuela, Bolivarian Republic of). Servicio de Radioterapia

    2010-07-01

    The evaluation of the treatment planning system (TPS) used in radiotherapy Precise Plan, was carried out using TLD-100 dosimeters, comparing the dose obtained with an ionization chamber. The TLD-100 were calibrated using secondary standard of SSDL, selecting dosimeters which had a standard deviation less than 1% for dosimeter calibration and less than 5% for dosimeter of field, for the tests conducted in TPS, The Alderson Phantom was used to evaluate the wedge and bolus, and Lucy 3D allowed us to evaluate correspondence of CT numbers, volume expansion, beam shaping, precise dose and beam weigh assignment. It was observed that the results of Lucy 3D were within the values expected except the volume expansion process with more than 10% difference, the evaluation of beam modulators systems with wedges and bolus as beam shaping yielded values within the expected with variations less than 5% and to assess the supply of specific doses, it was observed that the values obtained were precise and accurate since the same variation was less than 0.5% for the test. The importance of assessing the TPS lies in our country there is no procedure to verify that system and these tests provide a basis for future comparisons. (author)

  9. Determination of kinetic parameters in Tl dosemeters of LiF: Mg, Cu, P + PTFE developed in the ININ; Determinacion de parametros cineticos en dosimetros Tl de LiF: Mg, Cu, P + PTFE desarrollados en el ININ

    Energy Technology Data Exchange (ETDEWEB)

    Basurto G, B.S

    2002-07-01

    The objective of this work, is the one of determining the kinetic parameters of the dosemeter of LiF: Mg, Cu, P + Ptfe; starting from the curves Tl obtained at being irradiated with alpha radiation ({alpha}), beta ({beta}) and gamma ({gamma}). As like to compare its sensitivity with each radiation type, considering the sensitivity of the TLD-100 as the unit. In the Chapter 1, the fundamental structure of the matter is described, making emphasis in the different radiation types, and their interaction with this. In the Chapter 2, the units are described but used in the dosimetry of the radiation. In the Chapter 3, the basic concepts of the phenomenon of Tl are described and those are explained characteristic of the deconvolution method to determine the kinetics of the one phenomenon. In the Chapter 4, the methodology is detailed that was used in the elaboration of this thesis work, describing the material Tl that were considered like reference, as well as the sources of ionizing radiation, with those that the dosemeters were irradiated and the equipment in the one that the curves Tl was obtained. Reference is made to the software used to carry out the deconvolution of the curves Tl that were obtained in the one experimental development. In the Chapter 5, the obtained results of this study are presented, showing the tables of homogenization of dosemeters and the reading of the same one; they are observed the curves Tl obtained to different radiation doses (alpha, beta and gamma), the intensity Tl in function of the dose. Also they are tabulated, the obtained results in the kinetic parameters of the three different study materials (TLD-100H, USA; TLD-100, USA and LiF: Mg, Cu, P + Ptfe developed in the l.N.l.N). They are analyzed shortly for each material Tl their sensitivity to the ionizing radiation as well as their kinetic parameters. The obtained results showed that the Tl dosemeters of LiF: Mg,Cu,P + Ptfe, they presented a bigger sensitivity that the TLD-100 when

  10. Determination of kinetic parameters in Tl dosemeters of LiF: Mg, Cu, P + PTFE developed in the ININ

    International Nuclear Information System (INIS)

    Basurto G, B.S.

    2002-01-01

    The objective of this work, is the one of determining the kinetic parameters of the dosemeter of LiF: Mg, Cu, P + Ptfe; starting from the curves Tl obtained at being irradiated with alpha radiation (α), beta (β) and gamma (γ). As like to compare its sensitivity with each radiation type, considering the sensitivity of the TLD-100 as the unit. In the Chapter 1, the fundamental structure of the matter is described, making emphasis in the different radiation types, and their interaction with this. In the Chapter 2, the units are described but used in the dosimetry of the radiation. In the Chapter 3, the basic concepts of the phenomenon of Tl are described and those are explained characteristic of the deconvolution method to determine the kinetics of the one phenomenon. In the Chapter 4, the methodology is detailed that was used in the elaboration of this thesis work, describing the material Tl that were considered like reference, as well as the sources of ionizing radiation, with those that the dosemeters were irradiated and the equipment in the one that the curves Tl was obtained. Reference is made to the software used to carry out the deconvolution of the curves Tl that were obtained in the one experimental development. In the Chapter 5, the obtained results of this study are presented, showing the tables of homogenization of dosemeters and the reading of the same one; they are observed the curves Tl obtained to different radiation doses (alpha, beta and gamma), the intensity Tl in function of the dose. Also they are tabulated, the obtained results in the kinetic parameters of the three different study materials (TLD-100H, USA; TLD-100, USA and LiF: Mg, Cu, P + Ptfe developed in the l.N.l.N). They are analyzed shortly for each material Tl their sensitivity to the ionizing radiation as well as their kinetic parameters. The obtained results showed that the Tl dosemeters of LiF: Mg,Cu,P + Ptfe, they presented a bigger sensitivity that the TLD-100 when being

  11. Comparative study of trapping parameters of LiF(TLD-100) from different production batches

    Energy Technology Data Exchange (ETDEWEB)

    Bos, A.J.J.; Piters, T.M.; Vries, W. de; Hoogenboom, J.E. (Delft Univ. of Technology (Netherlands). Interfaculty Reactor Institute)

    1990-01-01

    Computerised glow curve analysis has been used to determine the trapping parameters of the main peaks of the thermoluminescent (TL) material LiF(TLD-100). The TL material (solid state chips) originated from six different production batches with at least 19 chips per batch. The maxima of glow peaks 2 to 5 are found at the same temperature within very small limits. The activation energy and frequency factor of the main glow peak (peak 5) of TLD-100 originating from two batches differ significantly from those of the other four investigated batches. Nevertheless, the sensitivity of glow peak 5 is more or less the same for all batches. The trapping parameters of glow peaks 2 to 4 of TLD-100 vary little from batch to batch. The measured half-life of peak 2 differed strongly from batch to batch. For all investigated peaks no correlation has been found between glow peak sensitivity and trapping parameters. The results of this study suggest that both defect concentration and nature of the trapping centres vary from batch to batch. It would appear that as a consequence of selection by the manufacturer, the differences between the batches in terms of total light output are small. (author).

  12. Thermoluminescence of gamma rays irradiated LiF nanocubes doped with different elements

    International Nuclear Information System (INIS)

    Salah, Numan; Alharbi, Najlaa D.; Habib, Sami S.

    2015-01-01

    Lithium fluoride (LiF) doped with proper activator is a highly sensitive phosphor, widely used as a dosimeter for ionizing radiations. This work reports on the thermoluminesence (TL) response of LiF nanocubes doped with different impurities. These nanocubes were synthesized by the co-precipitation method and characterized by different techniques. The dopants used in this study are Eu, Tb, Dy, Cu and Ag. The gamma radiation induced TL glow peaks are located in the temperature range 120–125 °C. These samples have different TL sensitivities, where Eu doped one is found to be the most TL sensitive. Further irradiations in the dose range from 10 Gy to 30 kGy were performed to LiF:Eu and the obtained result is explained using a proposed multilevel TL model. According to this model, Eu dopant (in Eu 3+ ionic form) could induce shallow and deep electron traps in the host of LiF nanocubes. These traps differ in their response according to the doses. The optimum concentration of Eu ions in LiF host is found to be 0.2 mol%. It is also found that LiF nanocubes are thermally stable in the range of 30–400 °C with a single phase. This property along with the good sensitivity of Eu doped one makes this tissue equivalent nanomaterial a proper candidate for heavy dose measurement like swift heavy ions used in radiotherapy. - Highlights: • Nanocubes of pure and doped LiF were produced by the co-precipitation method. • They were doped with Eu, Tb, Dy, Cu and Ag and studied for their TL response. • The gamma radiation induced TL glow peaks are located in the range 120–125 °C. • The Eu doped one is found to be the most TL sensitive, followed by Tb. • The tissue equivalent LiF:Eu nanocubes might be useful for heavy dose measurement

  13. SU-E-I-09: Application of LiF:Mg,Cu (TLD-100H) Dosimeters for in Diagnostic Radiology

    International Nuclear Information System (INIS)

    Sina, S; Zeinali, B; Karimipourfard, M; Lotfalizadeh, F; Sadeghi, M; Faghihi, R

    2014-01-01

    Purpose: Accurate dosimetery is very essential in diagnostic radiology. The goal of this study is to verify the application of LiF:Mg,Cu,P (TLD100H) in obtaining the Entrance skin dose (ESD) of patients undergoing diagnostic radiology. The results of dosimetry performed by TLD-100H, were compared with those obtained by TLD100, which is a common dosimeter in diagnostic radiology. Methods: In this study the ESD values were measured using two types of Thermoluminescence dosimeters (TLD-100, and TLD-100H) for 16 patients undergoing diagnostic radiology (lumbar spine imaging). The ESD values were also obtained by putting the two types of TLDs at the surface of Rando phantom for different imaging techniques and different views (AP, and lateral). The TLD chips were annealed with a standard procedure, and the ECC values for each TLD was obtained by exposing the chips to equal amount of radiation. Each time three TLD chips were covered by thin dark plastic covers, and were put at the surface of the phantom or the patient. The average reading of the three chips was used for obtaining the dose. Results: The results show a close agreement between the dose measuered by the two dosimeters.According to the results of this study, the TLD-100H dosimeters have higher sensitivities (i.e.signal(nc)/dose) than TLD-100.The ESD values varied between 2.71 mGy and 26.29 mGy with the average of 11.89 mGy for TLD-100, and between 2.55 mGy and 27.41 mGy with the average of 12.32 mGy for measurements. Conclusion: The TLD-100H dosimeters are suggested as effective dosimeters for dosimetry in low dose fields because of their higher sensitivities

  14. SU-E-I-09: Application of LiF:Mg,Cu (TLD-100H) Dosimeters for in Diagnostic Radiology

    Energy Technology Data Exchange (ETDEWEB)

    Sina, S [Radiation Research Center, Shiraz University, Shiraz (Iran, Islamic Republic of); Zeinali, B; Karimipourfard, M; Lotfalizadeh, F; Sadeghi, M [Nuclear Engineering Department, Shiraz University, Shiraz (Iran, Islamic Republic of); Faghihi, R [Radiation Research Center, Shiraz University, Shiraz (Iran, Islamic Republic of); Nuclear Engineering Department, Shiraz University, Shiraz (Iran, Islamic Republic of)

    2014-06-01

    Purpose: Accurate dosimetery is very essential in diagnostic radiology. The goal of this study is to verify the application of LiF:Mg,Cu,P (TLD100H) in obtaining the Entrance skin dose (ESD) of patients undergoing diagnostic radiology. The results of dosimetry performed by TLD-100H, were compared with those obtained by TLD100, which is a common dosimeter in diagnostic radiology. Methods: In this study the ESD values were measured using two types of Thermoluminescence dosimeters (TLD-100, and TLD-100H) for 16 patients undergoing diagnostic radiology (lumbar spine imaging). The ESD values were also obtained by putting the two types of TLDs at the surface of Rando phantom for different imaging techniques and different views (AP, and lateral). The TLD chips were annealed with a standard procedure, and the ECC values for each TLD was obtained by exposing the chips to equal amount of radiation. Each time three TLD chips were covered by thin dark plastic covers, and were put at the surface of the phantom or the patient. The average reading of the three chips was used for obtaining the dose. Results: The results show a close agreement between the dose measuered by the two dosimeters.According to the results of this study, the TLD-100H dosimeters have higher sensitivities (i.e.signal(nc)/dose) than TLD-100.The ESD values varied between 2.71 mGy and 26.29 mGy with the average of 11.89 mGy for TLD-100, and between 2.55 mGy and 27.41 mGy with the average of 12.32 mGy for measurements. Conclusion: The TLD-100H dosimeters are suggested as effective dosimeters for dosimetry in low dose fields because of their higher sensitivities.

  15. Proton/gamma relative thermoluminescence efficiencies of LiF:Mg,Cu,P+PTFE prepared at ININ and TLD-100H

    International Nuclear Information System (INIS)

    Avila, O.; Gonzalez, P.; Murillo, G.

    2009-10-01

    Properties of LiF:Mg,Cu,P+PTFE dosemeters developed at ININ have been investigated in order to evaluate their performance compared to those of equivalent commercial dosemeters. In this work both LiF:Mg,Cu,P+PTFE and TLD-100H pellets were exposed to low fluence 3 MeV protons and to low dose gamma radiation to evaluate experimental proton/gamma efficiencies. Gamma irradiation was performed using the Vic krad irradiator at ININ at varying doses between 25 and 500 mGy. For proton irradiation the Tandem Van de Graaff accelerator at ININ was used. Dosemeters were placed on a holder inside a scattering chamber where protons impinge on a gold target and scatter in all directions. The holder allows for several angular positions so that dosemeters receive proton fluence between 10 6 and 10 1 0 p/cm 2 . Experimental efficiency values found for LiF:Mg,Cu,P+PTFE and TLD-100H were 0.18 +- 03 and 0.23 +- 0.03, respectively. These results allow to confirm the reliability of the dosemeters developed at ININ. (Author)

  16. Thermoluminescence of gamma rays irradiated LiF nanocubes doped with different elements

    Energy Technology Data Exchange (ETDEWEB)

    Salah, Numan, E-mail: nsalah@kau.edu.sa [Center of Nanotechnology, King Abdulaziz University, Jeddah 21589 (Saudi Arabia); Alharbi, Najlaa D. [Center of Nanotechnology, King Abdulaziz University, Jeddah 21589 (Saudi Arabia); Sciences Faculty for Girls, King Abdulaziz University, Jeddah 21589 (Saudi Arabia); Habib, Sami S. [Department of Aeronautical Engineering, King Abdulaziz University, Jeddah 21589 (Saudi Arabia)

    2015-05-15

    Lithium fluoride (LiF) doped with proper activator is a highly sensitive phosphor, widely used as a dosimeter for ionizing radiations. This work reports on the thermoluminesence (TL) response of LiF nanocubes doped with different impurities. These nanocubes were synthesized by the co-precipitation method and characterized by different techniques. The dopants used in this study are Eu, Tb, Dy, Cu and Ag. The gamma radiation induced TL glow peaks are located in the temperature range 120–125 °C. These samples have different TL sensitivities, where Eu doped one is found to be the most TL sensitive. Further irradiations in the dose range from 10 Gy to 30 kGy were performed to LiF:Eu and the obtained result is explained using a proposed multilevel TL model. According to this model, Eu dopant (in Eu{sup 3+} ionic form) could induce shallow and deep electron traps in the host of LiF nanocubes. These traps differ in their response according to the doses. The optimum concentration of Eu ions in LiF host is found to be 0.2 mol%. It is also found that LiF nanocubes are thermally stable in the range of 30–400 °C with a single phase. This property along with the good sensitivity of Eu doped one makes this tissue equivalent nanomaterial a proper candidate for heavy dose measurement like swift heavy ions used in radiotherapy. - Highlights: • Nanocubes of pure and doped LiF were produced by the co-precipitation method. • They were doped with Eu, Tb, Dy, Cu and Ag and studied for their TL response. • The gamma radiation induced TL glow peaks are located in the range 120–125 °C. • The Eu doped one is found to be the most TL sensitive, followed by Tb. • The tissue equivalent LiF:Eu nanocubes might be useful for heavy dose measurement.

  17. Stability of the post irradiation traps in LiF: Mg, Cu, P

    International Nuclear Information System (INIS)

    Gonzalez, P.R.; Furetta, C.; Azorin, J.

    2004-01-01

    In this work the results of the study of the stability of the traps are presented in dosemeters Tl of LiF: Mg,Cu,P, irradiated with gamma radiation of 60 Co. The studied dosemeters were of LiF: Mg,Cu,P + Ptfe, developed in the ININ, taking like reference to the commercial dosemeter GR200A of Chinese manufacture. Before being exposed to the radiation, the dosemeters received their standard treatment from having erased, two hours after the irradiation they took the initial readings. The dosemeters faded again and they were irradiated to the same dose, soon after they stayed under normal conditions, protected of the light, later on they were taken their readings periodically during six months. The readings taken Tl the same day of the irradiation presented four peaks whose energy, determined by the deconvolution method were; 1.30 ± 0.01 eV, 1.50 ± 0.01 eV, 1.70 ± 0.01 eV and 2.58 ± 0.02 eV, for LiF: Mg,Cu,P + Ptfe, while GR200A stops the energy they were: 1.33 ± 0.11 eV, 1.58 ± 0.11 eV, 1.73 ± 0.11 eV and 2.60 ± 0.03 eV. In both cases the peak 1, with the energy but it lowers, it disappears completely after some later hours to the irradiation, while the peak 2, it disappears completely after 122 days for the local dosemeter and after 94 days for the commercial dosemeter. The energy of the peaks 3 and 4 that remained visible during the whole period of study it was: 1.38 ± 0.01 eV and 2.65 ± 0.01 eV, for LiF: Mg,Cu,P + Ptfe respectively, in the same order for GR200A, the energies were: 1.51 ± 0.02 eV and 2.64 ± 0.03 eV. In all the cases the peaks with energy below 2 eV, showed tendency to the drop, while the main peak, showed certain tendency to increase, as they show it the results. (Author)

  18. Experimental determination of relative light conversion factors of TLD-100 for protons with energies from 2.0 to 9.0 MeV

    International Nuclear Information System (INIS)

    Schmidt, P.; Fellinger, J.; Huebner, K.; Henniger, J.

    1985-01-01

    Relative light conversion factors (RLCF) for heavy charged particles (protons, deuterons, recoils) are needed for the calculation of the neutron sensitivity of thermoluminescent (TL) detectors. Such light conversion factors can be determined experimentally. A method is represented for the experimental determination of RLCF. The described experimental facility gives the possibility of irradiation of different luminophor samples with heavy charged particles and flux determination and particle spectrometry at the same time. For the determination of RLCF the doses are needed which are applicated at the irradiation with heavy charged particles and gamma radiation, respectively, and the according detector readings at the TL evaluation. The problems arising at the dose determination are discussed. With this experimental facility the RLCF for TLD-100 for protons were determined. The relative light conversion factors determined according to the light sum method as well as the peak height method are summarizinhly represented and discussed. Furthermore a comparison of the glow curves is made after gamma and proton irradiation

  19. The Dependence of the Dose Response Supralinearity of Peak 5 in TLD-100 on Recombination Temperature

    International Nuclear Information System (INIS)

    Horowitz, Y.S.; Satinger, D.; Oster, L.

    1999-01-01

    Isothermal readout of LiF:Mg,Ti (TLD-700) has recently been used to study the dependence of the supralinearity of peak 5 on recombination temperature. The results were interpreted to be in conflict with earlier results which investigated the effect of readout heating rate on the supralinearity of peak 5 in TLD-100. In this work the two experiments are inspected in greater detail. It is illustrated that the isothermal decay data is not in conflict with the heating rate data. However, the heating rate results do apparently indicate a strong transition in the temperature dependence of the relative strengths of the recombination and competitive cross sections at approximately 235 deg. C, which requires further study and analysis. (author)

  20. Stability of the post irradiation traps in LiF: Mg, Cu, P; Estabilidad de las trampas posradiacion en LiF: Mg, Cu, P

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, P.R. [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico); Furetta, C. [Physics Department, Rome University ' ' La Sapienza' ' , Rome (Italy); Azorin, J. [UAM-I, 09340 Mexico D.F. (Mexico)

    2004-07-01

    In this work the results of the study of the stability of the traps are presented in dosemeters Tl of LiF: Mg,Cu,P, irradiated with gamma radiation of {sup 60} Co. The studied dosemeters were of LiF: Mg,Cu,P + Ptfe, developed in the ININ, taking like reference to the commercial dosemeter GR200A of Chinese manufacture. Before being exposed to the radiation, the dosemeters received their standard treatment from having erased, two hours after the irradiation they took the initial readings. The dosemeters faded again and they were irradiated to the same dose, soon after they stayed under normal conditions, protected of the light, later on they were taken their readings periodically during six months. The readings taken Tl the same day of the irradiation presented four peaks whose energy, determined by the deconvolution method were; 1.30 {+-} 0.01 eV, 1.50 {+-} 0.01 eV, 1.70 {+-} 0.01 eV and 2.58 {+-} 0.02 eV, for LiF: Mg,Cu,P + Ptfe, while GR200A stops the energy they were: 1.33 {+-} 0.11 eV, 1.58 {+-} 0.11 eV, 1.73 {+-} 0.11 eV and 2.60 {+-} 0.03 eV. In both cases the peak 1, with the energy but it lowers, it disappears completely after some later hours to the irradiation, while the peak 2, it disappears completely after 122 days for the local dosemeter and after 94 days for the commercial dosemeter. The energy of the peaks 3 and 4 that remained visible during the whole period of study it was: 1.38 {+-} 0.01 eV and 2.65 {+-} 0.01 eV, for LiF: Mg,Cu,P + Ptfe respectively, in the same order for GR200A, the energies were: 1.51 {+-} 0.02 eV and 2.64 {+-} 0.03 eV. In all the cases the peaks with energy below 2 eV, showed tendency to the drop, while the main peak, showed certain tendency to increase, as they show it the results. (Author)

  1. Magnetoplastic effect in irradiated NaCl and LiF crystals

    International Nuclear Information System (INIS)

    Al'shitz, V.I.; Darinskaya, E.V.; Kazakova, O.L.

    1997-01-01

    The effect of low x-ray irradiation doses (≅10 2 rad) on the magnetoplastic effect - the detachment of dislocations from paramagnetic centers under the action of an external magnetic field B - in alkali-halide crystals has been investigated. The measurements were performed on LiF crystals and three types of NaCl crystals, differing in impurity content. The dependence of the mean free path l of the dislocations on the rotational frequency ν of a sample in a magnetic field was especially sensitive to low irradiation doses. In unirradiated crystals this dependence is a single-step dependence and is characterized by a critical frequency ν c ∝B 2 above which the magnetoplastic effect is not observed. The frequency ν c depends only on the type of paramagnetic centers, and not on their density. Even the lowest irradiation dose employed ( c2 , that is insensitive to the irradiation dose, and that corresponds to the appearance of magnetically sensitive stoppers of a new type under irradiation. The initial critical frequency ν c1 , as a rule, also varies with the dose, reflecting the change in state of the impurity complexes (Ca in NaCl and Mg in LiF). Specifically, it is shown for NaCl(Ca) crystals that as the irradiation dose increases, the frequency ν c1 increases, gradually approaching the value ν c2 , so that by the time the dose is ≅300 rad, the dependence l(ν) once again becomes a single-step dependence, dropping sharply only for ν≥ν c2 . It is shown that the addition of a small number of Ni atoms to a NaCl crystal makes the Ca complexes radiation resistant, and the critical frequency ν c1 corresponding to them initially equals ν c2 for crystals with no Ni. The recombination kinetics of radiation defects in the case in which the samples are irradiated under a tungsten lamp was investigated. A possible physical model of the observed dependences is discussed

  2. A study of point defect aggregates in #betta#-irradiated LiF single crystals

    International Nuclear Information System (INIS)

    Frugoli, P.A.; Pimentel, C.A.F.

    1982-11-01

    Diffuse X-ray scattering near the Bragg Reflection and Bragg profile analaysis have been made in #betta#-irradiated LiF single crystal X-ray diffractometer. An estimate of the half-width of the diffraction patterns was done and preferential alteration in the profile parameters was observed. Clusters with mean parameter sizes from hundreds to thousands of angstroms were observed but each sample has presented a set of average size values. The nature of clusters was found to be dependent on the #betta#-dose: vacancy at low dose (approximately 10 MRad) and interstitial at high dose (approximately 50 MRad). Some process of coalescence at 50 MRad seems to occur. (Author) [pt

  3. PTTL Dose Re-estimation Applied to Quality Control in TLD-100 Based Personal Dosimetry

    International Nuclear Information System (INIS)

    Muniz, J.L.; Correcher, V.; Delgado, A.

    1999-01-01

    A new method for quality control of dose performance in Personal Dosimetry using TLD-100 is presented. This method consists of the application of dose reassessment techniques based on phototransferred thermoluminescence (PTTL). Reassessment is achieved through a second TL readout of the dosemeters worn by the controlled workers, after a reproducible UV exposure. Recent refinements in the PTTL technique developed in our laboratory allow reassessing doses as low as 0.2 mSv, thus extending the reassessment capability to the entire dose range that must be monitored in personal dosimetry. After a one month exposure, even purely environmental doses can be reassessed. This method can be applied for either re-estimation of single doses or of the total dose accumulated after a number of exposures and dose measurements. Several tests to reconfirm low doses in normal working conditions for personal dosimetry have been performed. Each test consisted of several cycles of exposure and TL evaluations and a final PTTL re-estimation of the total accumulated dose in those cycles. The results obtained always showed very good agreement between the sum of the partial doses and the total reassessed dose. The simplicity of the method and the possibility of re-evaluating the doses assessed to the workers employing their own dosemeters are advantageous features to be considered in designing systems for the determination of real performance in personal dosimetry. (author)

  4. Reproducibility study of TLD-100 micro-cubes at radiotherapy dose level

    International Nuclear Information System (INIS)

    Rosa, Luiz Antonio R. da; Regulla, Dieter F.; Fill, Ute A.

    1999-01-01

    The precision of the thermoluminescent response of Harshaw micro-cube dosimeters (TLD-100), evaluated in both Harshaw thermoluminescent readers 5500 and 3500, for 1 Gy dose value, was investigated. The mean reproducibility for micro-cubes, pre-readout annealed at 100 deg. C for 15 min, evaluated with the manual planchet reader 3500, is 0.61% (1 standard deviation). When micro-cubes are evaluated with the automated hot-gas reader 5500, reproducibility values are undoubtedly worse, mean reproducibility for numerically stabilised dosimeters being equal to 3.27% (1 standard deviation). These results indicate that the reader model 5500, or, at least, the instrument used for the present measurements, is not adequate for micro-cube evaluation, if precise and accurate dosimetry is required. The difference in precision is apparently due to geometry inconsistencies in the orientation of the imperfect micro-cube faces during readout, requiring careful and manual reproducible arrangement of the selected micro-cube faces in contact with the manual reader planchet

  5. Characteristics of new LiF preparations and sensitised LiF

    Energy Technology Data Exchange (ETDEWEB)

    Driscoll, C M.H.; O' Hagan, J B; Mundy, S J; Todd, C D; McWhan, A F; Dodson, J

    1986-01-01

    The patent governing the preparation and production of lithium fluoride (LiF) awarded to the Harshaw Chemical Co. has expired. Other companies have become interested in developing additional preparations of this material. Two of these preparations include LiF:Mg,Ti manufactured by Vinten Instruments plc and high sensitivity LiF:Mg, Cu,P distributed by them. The properties of these materials, including sensitivity, dose threshold, photon energy response, reusability and storage characteristics, are presented in this paper and compared with those of Harshaw TLD-100 and with those of sensitised LiF.

  6. Personal dosimetry TLD 100 in orthopedic surgeons exposed to ionizing radiation in Bogota - Colombia

    International Nuclear Information System (INIS)

    Sierra C, B. Y.; Jimenez, Y.; Plazas, M. C.; Eslava S, J.; Groot R, H.

    2014-08-01

    Orthopedic surgeons should be considered as professionals occupationally exposed to ionizing radiation, for using C arc (fluoroscope) an equipment of X type radiation emission, during surgical procedures for imaging generation. Some health institutes, use of C arc under uncontrolled circumstances, such a lack of dosimetry control, incomplete or absence of personnel protective elements and protective measures, which in turn, lead to a high exposition to the personnel. Materials and methods. Study of double match cohort by age and gender, was conducted, in four health institutions of second and third level of attention in Bogota city. Personal dosimetry measurements with TLD-100 dosimetry crystals in both cohorts and environmental dosimetry in each of operation rooms used for orthopedic procedures, were carry out during six months of follow up. Dosimetry crystals were read in a Harshaw 4500 - Bicron equipment, in the Medical Physics Laboratory of National University of Colombia. Results. Dosimetry measurements are compatibles with those of occupationally exposed personnel 3.44 mSv/6 m CI 95% (1.66-3.99), even does not overpass ICRP recommendations, are higher as were expect at the beginning of the study. The median of effective accumulative dose in thorax is 3,4 mSv CI 95% (1,66-3,99), higher in comparison with neck value 2,7 mSv CI 95% (1,73-3,80) and hand dosimetry 1,42 mSv CI 95% (0,96-2,34). Conclusions: Orthopedic surgeons should be considered occupational exposed to ionizing radiation, who has to accomplish to the radiological protection measures, dosimetric follow up and maintenance of the used X ray equipment. It was confirm throughout this study that dosimetry shows higher levels as expected at the beginning of the study, compatible with occupationally exposed personnel. (Author)

  7. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of high temperature peaks in TLD-100 dosemeters; Eficiencias termoluminiscentes relativas proton/gamma y helio/gamma de picos de alta temperatura en dosimetros TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Flores M, E.; Avila, O.; Rodriguez V, M. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico); Massillon, J.L.G.; Buenfil A, E.; Ruiz T, C.; Brandan, M.E. [IFUNAM, 04500 Mexico D.F. (Mexico); Gamboa De Buen, I. [ICN-UNAM, 04500 Mexico D.F. (Mexico)

    2007-07-01

    This work presents measures of relative thermoluminescent efficiency of those high temperature peaks of TLD-100 dosemeters exposed to protons of 1.5 MeV and to helium nuclei of 3 and 7.5 MeV. A rigorous reading and of deconvolution protocol was used for the calculation of the TL efficiencies. Additionally an Excel program that facilitated the deconvolution adjustment process of the glow curves was elaborated. (Author)

  8. TLD-100 glow-curve deconvolution for the evaluation of the thermal stress and radiation damage effects

    CERN Document Server

    Sabini, M G; Cuttone, G; Guasti, A; Mazzocchi, S; Raffaele, L

    2002-01-01

    In this work, the dose response of TLD-100 dosimeters has been studied in a 62 MeV clinical proton beams. The signal versus dose curve has been compared with the one measured in a sup 6 sup 0 Co beam. Different experiments have been performed in order to observe the thermal stress and the radiation damage effects on the detector sensitivity. A LET dependence of the TL response has been observed. In order to get a physical interpretation of these effects, a computerised glow-curve deconvolution has been employed. The results of all the performed experiments and deconvolutions are extensively reported, and the TLD-100 possible fields of application in the clinical proton dosimetry are discussed.

  9. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of high temperature peaks in TLD-100 dosemeters

    International Nuclear Information System (INIS)

    Flores M, E.; Avila, O.; Rodriguez V, M.; Massillon, J.L.G.; Buenfil A, E.; Ruiz T, C.; Brandan, M.E.; Gamboa De Buen, I.

    2007-01-01

    This work presents measures of relative thermoluminescent efficiency of those high temperature peaks of TLD-100 dosemeters exposed to protons of 1.5 MeV and to helium nuclei of 3 and 7.5 MeV. A rigorous reading and of deconvolution protocol was used for the calculation of the TL efficiencies. Additionally an Excel program that facilitated the deconvolution adjustment process of the glow curves was elaborated. (Author)

  10. Characterization of the personal thermoluminescent dosemeter of LiF: Mg, Ti + Ptfe

    International Nuclear Information System (INIS)

    Azorin N, J.; Gutierrez C, A.; Gonzalez M, P.

    1991-01-01

    The objective of this work is to characterize the thermoluminescent dosemeters taken place in the laboratory in form of pellets of LiF: Mg, Ti + Ptfe like personal dosemeters, subjecting them to the operation tests proposed by the international standards and comparing them with the TLD-100, the Tl dosemeter more used at the moment for personal dosimetry

  11. Fading of the Tl signal in LiF: Mg, Cu, P during a large post irradiation period

    International Nuclear Information System (INIS)

    Gonzalez, P.R.; Azorin, J.; Furetta, C.

    2004-01-01

    In this work the obtained results of the study of the fading of the Tl signal in dosemeters of LiF activated with magnesium, copper and phosphorus (LiF:Mg,Cu,P) are presented. The studied dosemeters were LiF: Mg,Cu,P + Ptfe, developed in the ININ, taking like reference to the commercial dosemeter GR200A of Chinese manufacture. In both cases the Tl curve presents four peaks; in LiF: Mg,Cu,P + Ptfe, the peaks of smaller size appear in 359 K, 389 K and 447 K, the main dosimetric peak appears in 486 K; in GR200A, the peaks of smaller size appear in 360 K, 389 K and 445 K; while the main dosimetric peak appears in 487 K. The highest fading shown by the dosemeters of LiF: Mg,Cu,P + Ptfe, it was of 3.07%, value very below the one recommended for dosimetric purposes. While the commercial dosemeters presented a fading until of 6.23%, surpassing with the recommended values. The observed fading, it corresponds to the lost of the Tl signal of the peaks 1 and 2, since the first one disappears few hours after the irradiation, while the peak 2, it disappears completely after 94 days, the peak 3 remained stable during the six months of study, while the peak 4, it showed a slight increment due to the contribution of the dose of natural environmental radiation. (Author)

  12. Dosimetric evaluation of the response of the TLD-100 dosemeters in the IMRT technique by 'Step and Shoot'; Evaluacion dosimetrica de la respuesta de los dosimetros TLD-100 en la tecnica de IMRT por 'Step and Shoot'

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, J. [Fundacion Clinica Valle del Lili, A.A. 020338, Cali (Colombia); Benavides, S.O. [Depto. de Fisica, Universidad del Valle, A.A. 25360, Cali (Colombia)

    2005-07-01

    We show the results of the dosimetry response of LiF thermoluminescent crystals: TLD-100, where they were radiated in a linear accelerator Siemens Primus Hl using the Intensity Modulated Radiation Therapy (IMRT) by step and shoot technique. Previous to the crystals calibration and response evaluation, the acceptation procedures recommended by the TG-53 protocol for validation of the technique were carried out. The planning system utilized was the Theraplan Plus 3.8, using the algorithm of Pencil Kernel. The register and verification system was Lantis 5.2. The response curve of dose versus charge was obtained from the readings of the TLD in a Harshaw 3500. The crystals were radiated in a Bench- Marck phantom with doses previously determined by using ionization chambers for square radiation fields, in a beam with a 0.68 TPR20,10 corresponding to 6 MV of energy. We compare the response of these through of radiation of segmented fields in a Anthropomorphic phantom and the calculated doses by the planning system. The results obtained in the crystals response show deviations less than 5 % between the measured dose and the calculated dose in the zones of low gradient. It allows its implementation like routine control of quality by IMRT. (Author)

  13. Primary and aggregate color centers in proton irradiated LiF crystals and thin films for luminescent solid state detectors

    International Nuclear Information System (INIS)

    Piccinini, M; Ambrosini, F; Ampollini, A; Bonfigli, F; Libera, S; Picardi, L; Ronsivalle, C; Vincenti, M A; Montereali, R M

    2015-01-01

    Proton beams of 3 MeV energy, produced by the injector of a linear accelerator for proton therapy, were used to irradiate at room temperature lithium fluoride crystals and polycrystalline thin films grown by thermal evaporation. The irradiation fluence range was 10 11 -10 15 protons/cm 2 . The proton irradiation induced the stable formation of primary and aggregate color centers. Their formation was investigated by optical absorption and photoluminescence spectroscopy. The F 2 and F 3 + photoluminescence intensities, carefully measured in LiF crystals and thin films, show linear behaviours up to different maximum values of the irradiation fluence, after which a quenching is observed, depending on the nature of the samples (crystals and films). The Principal Component Analysis, applied to the absorption spectra of colored crystals, allowed to clearly identify the formation of more complex aggregate defects in samples irradiated at highest fluences. (paper)

  14. Primary and aggregate color centers in proton irradiated LiF crystals and thin films for luminescent solid state detectors

    Science.gov (United States)

    Piccinini, M.; Ambrosini, F.; Ampollini, A.; Bonfigli, F.; Libera, S.; Picardi, L.; Ronsivalle, C.; Vincenti, M. A.; Montereali, R. M.

    2015-04-01

    Proton beams of 3 MeV energy, produced by the injector of a linear accelerator for proton therapy, were used to irradiate at room temperature lithium fluoride crystals and polycrystalline thin films grown by thermal evaporation. The irradiation fluence range was 1011-1015 protons/cm2. The proton irradiation induced the stable formation of primary and aggregate color centers. Their formation was investigated by optical absorption and photoluminescence spectroscopy. The F2 and F3+ photoluminescence intensities, carefully measured in LiF crystals and thin films, show linear behaviours up to different maximum values of the irradiation fluence, after which a quenching is observed, depending on the nature of the samples (crystals and films). The Principal Component Analysis, applied to the absorption spectra of colored crystals, allowed to clearly identify the formation of more complex aggregate defects in samples irradiated at highest fluences.

  15. Hardening and formation of dislocation structures in LiF crystals irradiated with MeV-GeV ions

    CERN Document Server

    Manika, I; Schwartz, K; Trautmann, C

    2002-01-01

    Material modifications of LiF crystals irradiated with Au, Pb and Bi ions of MeV to GeV energy are studied by means of microindentation measurements and dislocation etching. Above a critical irradiation fluence of 10 sup 9 ions/cm sup 2 , the microhardness can improve by a factor of 2 in the bulk and by more than 3 on the surface. Radiation-induced hardening follows the evolution of the energy loss along the ion path. Annealing experiments indicate that complex defect aggregates created in the tracks play a major role for the hardness change. Evidence for severe structural modifications is found when etching indentation impressions in highly irradiated crystals leading to similar pattern as in amorphous or micro-grained materials. Dislocation etching also reveals long-range stress fields extending far beyond the implantation zone deep into the nonirradiated crystal.

  16. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of peaks of high temperature in TLD-100 dosemeters; Eficiencias termoluminiscentes relativas proton/gamma y helio/gamma de picos de alta temperatura en dosimetros TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Flores M, E. [UNAM, Facultad de Ciencias, 04510 Mexico D.F. (Mexico)

    2007-07-01

    The increase of the applications of ion beams in radiotherapy treatments has generated interest in the study of the thermoluminescent materials (TL) that allow to determine the applied doses. A way to quantify the TL response from these materials to ions is by means of the relative thermoluminescent efficiency. In the group of Thermoluminescent dosimetry of the Institute of Physics of the UNAM (IFUNAM) the thermoluminescent response of the TLD-100 dosemeters has been studied, which present a glow curve characteristic with several peaks that correspond to traps and luminescent centers in the material. The stable peaks know each other as 4, 5, 6a, 6b, 7, 8, 9 and 10. The efficiencies should be measured using the response so much to the radiation of interest (in this case protons and helium ions) as the response to gamma radiation. In previous works with ions of low energy taken place in the Pelletron accelerator of the IFUNAM was only measured the TL efficiency for the peak 5 and the total signal. It had not been possible to measure the efficiency of the peaks of high temperature (6a-10) because, for the gamma radiation, the peaks of high temperature show very small signals; however, recently Massillon carries out measures of efficiency TL of peaks of high temperature for ions of intermediate energy using a protocol special of reading and of deconvolution that allows to measure the signals coming from the peaks of high temperature. In this work is implemented this same protocol to complete the study of TL efficiencies at low energy of protons and helium and to determine if the values of efficiency depend on the used reading protocol. For it is reported it measures of the relative efficiency of the peaks of high temperature from the TLD-100 exposed to protons of 1.5 MeV and nuclei of helium of 3 and 7.5 MeV. (Author)

  17. Fading of the Tl signal in LiF: Mg, Cu, P during a large post irradiation period; Desvanecimiento de la senal Tl en LiF: Mg, Cu, P durante un largo periodo posradiacion

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, P.R. [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico); Azorin, J. [UAM-I, 09340 Mexico D.F. (Mexico); Furetta, C. [Universidad de Roma, Piazzale Aldo Moro 2, Roma (Italy)

    2004-07-01

    In this work the obtained results of the study of the fading of the Tl signal in dosemeters of LiF activated with magnesium, copper and phosphorus (LiF:Mg,Cu,P) are presented. The studied dosemeters were LiF: Mg,Cu,P + Ptfe, developed in the ININ, taking like reference to the commercial dosemeter GR200A of Chinese manufacture. In both cases the Tl curve presents four peaks; in LiF: Mg,Cu,P + Ptfe, the peaks of smaller size appear in 359 K, 389 K and 447 K, the main dosimetric peak appears in 486 K; in GR200A, the peaks of smaller size appear in 360 K, 389 K and 445 K; while the main dosimetric peak appears in 487 K. The highest fading shown by the dosemeters of LiF: Mg,Cu,P + Ptfe, it was of 3.07%, value very below the one recommended for dosimetric purposes. While the commercial dosemeters presented a fading until of 6.23%, surpassing with the recommended values. The observed fading, it corresponds to the lost of the Tl signal of the peaks 1 and 2, since the first one disappears few hours after the irradiation, while the peak 2, it disappears completely after 94 days, the peak 3 remained stable during the six months of study, while the peak 4, it showed a slight increment due to the contribution of the dose of natural environmental radiation. (Author)

  18. Analysis of read-out heating rate effects on the glow peaks of TLD-100 using WinGCF software

    Energy Technology Data Exchange (ETDEWEB)

    Bauk, Sabar, E-mail: sabar@usm.my [Physics Section, School of Distance Education, Universiti Sains Malaysia, 11800 USM, Penang (Malaysia); Hussin, Siti Fatimah [School of Physics, Universiti Sains Malaysia, 11800 USM, Penang (Malaysia); Alam, Md. Shah [Physics Section, School of Distance Education, Universiti Sains Malaysia, 11800 USM, Penang (Malaysia); Physics Department, Shahjalal University of Science and Technology, Sylhet (Bangladesh)

    2016-01-22

    This study was done to analyze the effects of the read-out heating rate on the LiF:Mg,Ti (TLD-100) thermoluminescent dosimeters (TLD) glow peaks using WinGCF computer software. The TLDs were exposed to X-ray photons with a potential difference of 72 kVp and 200 mAs in air and were read-out using a Harshaw 3500 TLD reader. The TLDs were read-out using four read-out heating rates at 10, 7, 4 and 1 °C s{sup −1}. It was observed that lowering the heating rate could separate more glow peaks. The activation energy for peak 5 was found to be lower than that for peak 4. The peak maximum temperature and the integral value of the main peak decreased as the heating rate decreases.

  19. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of peaks of high temperature in TLD-100 dosemeters

    International Nuclear Information System (INIS)

    Flores M, E.

    2007-01-01

    The increase of the applications of ion beams in radiotherapy treatments has generated interest in the study of the thermoluminescent materials (TL) that allow to determine the applied doses. A way to quantify the TL response from these materials to ions is by means of the relative thermoluminescent efficiency. In the group of Thermoluminescent dosimetry of the Institute of Physics of the UNAM (IFUNAM) the thermoluminescent response of the TLD-100 dosemeters has been studied, which present a glow curve characteristic with several peaks that correspond to traps and luminescent centers in the material. The stable peaks know each other as 4, 5, 6a, 6b, 7, 8, 9 and 10. The efficiencies should be measured using the response so much to the radiation of interest (in this case protons and helium ions) as the response to gamma radiation. In previous works with ions of low energy taken place in the Pelletron accelerator of the IFUNAM was only measured the TL efficiency for the peak 5 and the total signal. It had not been possible to measure the efficiency of the peaks of high temperature (6a-10) because, for the gamma radiation, the peaks of high temperature show very small signals; however, recently Massillon carries out measures of efficiency TL of peaks of high temperature for ions of intermediate energy using a protocol special of reading and of deconvolution that allows to measure the signals coming from the peaks of high temperature. In this work is implemented this same protocol to complete the study of TL efficiencies at low energy of protons and helium and to determine if the values of efficiency depend on the used reading protocol. For it is reported it measures of the relative efficiency of the peaks of high temperature from the TLD-100 exposed to protons of 1.5 MeV and nuclei of helium of 3 and 7.5 MeV. (Author)

  20. Optical and EPR spectra of γ-irradiated glasses of the Ba(PO3)2-LiF system

    International Nuclear Information System (INIS)

    Bocharova, T.V.; Karapetyan, G.O.; Khalilev, V.D.; Yashchurzhinskaya, O.A.

    1985-01-01

    EPR and optical absorption spectra of the Be(PO 3 ) 2 -LiF system glasses are obtained. Introduction of LiF up to 60 mol. % doesn't lead to occurrence of an additional absorption band (AAB) and EPR signals connected with F-centers formed under γ-irradiation in the LiF monocrystal. As a result of γ-irradiation of glasses activated by terbium, radiation color centers (RCC) are formed, which are, probably, the centers of electron capture and possess no unambiguous correlation with the known paramagnetic centers (PMC). Parallel investigation into the thermal decolouration kinetics by the EPR and optical spectroscopy method is reliable for establishing correlation between AAB and PMC signals in EPR spectra

  1. Study of the influence of the time temperature profile on the minimum detectable dose of TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Meireles, Leonardo S.; Lacerda, Marco Aurelio S.; Meira-Belo, Luiz C.; Ferreira, Hudson R., E-mail: meirelesls@cdtn.br, E-mail: masl@cdtn.br, E-mail: lcmb@cdtn.br, E-mail: hrf@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-07-01

    Monitoring of workers and workplaces is an integral part of any radiation protection programme (RPP). It is essential to demonstrate compliance with regulations that limit the allowable dose to the public from manmade sources and to enable the responsible of the installations to verify compliance with the legal dose limits to the workers and ALARA goals. Thermoluminescent dosemeters (TLDs) are generally employed to assess the environmental and personnel doses. To completely characterize a TLD dosimetry system is fundamental to determine the Lowest Dose that the system is capable of measuring. As the amount of the light emitted by TLD material is a function of the time temperature profile (TTP), in the present study, the influence of the TTP on the Detection Threshold (MDD) of the LiF:Mg,Ti (TLD-100) detectors was evaluated. Eighteen different TTPs were tested for two different annealing processes: (I) utilization of the TTP itself and; (II) a microprocessor controlled oven annealing procedure. Results showed that TTP choice can influence significantly in the MDD values. The worst results were generally found for TLDs annealed by the TTP itself. The lack of pattern or the unexpected behavior to the influence of some parameters of the TTP on the calculated MDDs must be carefully investigated. Greater variations on the TTP parameters must be undertaken. Special attention must be also done on the methodology of calculating the MDDs. (author)

  2. Study of the influence of the time temperature profile on the minimum detectable dose of TLD-100

    International Nuclear Information System (INIS)

    Meireles, Leonardo S.; Lacerda, Marco Aurelio S.; Meira-Belo, Luiz C.; Ferreira, Hudson R.

    2013-01-01

    Monitoring of workers and workplaces is an integral part of any radiation protection programme (RPP). It is essential to demonstrate compliance with regulations that limit the allowable dose to the public from manmade sources and to enable the responsible of the installations to verify compliance with the legal dose limits to the workers and ALARA goals. Thermoluminescent dosemeters (TLDs) are generally employed to assess the environmental and personnel doses. To completely characterize a TLD dosimetry system is fundamental to determine the Lowest Dose that the system is capable of measuring. As the amount of the light emitted by TLD material is a function of the time temperature profile (TTP), in the present study, the influence of the TTP on the Detection Threshold (MDD) of the LiF:Mg,Ti (TLD-100) detectors was evaluated. Eighteen different TTPs were tested for two different annealing processes: (I) utilization of the TTP itself and; (II) a microprocessor controlled oven annealing procedure. Results showed that TTP choice can influence significantly in the MDD values. The worst results were generally found for TLDs annealed by the TTP itself. The lack of pattern or the unexpected behavior to the influence of some parameters of the TTP on the calculated MDDs must be carefully investigated. Greater variations on the TTP parameters must be undertaken. Special attention must be also done on the methodology of calculating the MDDs. (author)

  3. TL response of Eu activated LiF nanocubes irradiated by 85 MeV carbon ions

    Energy Technology Data Exchange (ETDEWEB)

    Salah, Numan, E-mail: nsalah@kau.edu.sa [Center of Nanotechnology, King Abdulaziz University, Jeddah 21589 (Saudi Arabia); Alharbi, Najlaa D. [Sciences Faculty for Girls, King Abdulaziz University, Jeddah 21589 (Saudi Arabia); Habib, Sami S. [Center of Nanotechnology, King Abdulaziz University, Jeddah 21589 (Saudi Arabia); Lochab, S.P. [Inter-University Accelerator Centre, Aruna Asaf Ali Marg, New Delhi 110067 (India)

    2015-09-01

    Carbon ions were found to be effective for cancer treatment. These heavy ions have a high relative biological effectiveness compared to those of photons. They have higher linear energy transfer and sharper Bragg peak with a very excellent local tumor control. However, the dose of these swift heavy ions needs to be measured with great accuracy. Lithium fluoride (LiF) is a highly sensitive phosphor widely used for radiation dosimetry. In this work Eu activated LiF nanocubes were exposed to 85 MeV C{sup 6+} ion beam and evaluated for their thermoluminescence (TL) response. Pellet forms of this nanomaterial were exposed to these ions in the fluence range 10{sup 9}–10{sup 13} ions/cm{sup 2}. The obtained result shows a prominent TL glow peak at around 320 °C, which is different than that induced by gamma rays. This glow peak exhibits a linear response in the range 10{sup 9}–10{sup 12} ions/cm{sup 2}, corresponding to the equivalent absorbed doses 0.273–273 kGy. The absorbed doses, penetration depths and main energy loss were calculated using TRIM code based on the Monte Carlo simulation. The supralinearity function and stopping power in this nanomaterial were also studied. The modification induced in the glow curve structure as a result of changing irradiation type might be utilized to use LiF:Eu nanocubes as a dosimeter for mixed filed radiations. Moreover, the wide linear response of LiF:Eu nanocubes along with the low fading are another imperative results suggesting that this nanomaterial might be a good candidate for carbon ions dosimetry.

  4. TL response of Eu activated LiF nanocubes irradiated by 85 MeV carbon ions

    International Nuclear Information System (INIS)

    Salah, Numan; Alharbi, Najlaa D.; Habib, Sami S.; Lochab, S.P.

    2015-01-01

    Carbon ions were found to be effective for cancer treatment. These heavy ions have a high relative biological effectiveness compared to those of photons. They have higher linear energy transfer and sharper Bragg peak with a very excellent local tumor control. However, the dose of these swift heavy ions needs to be measured with great accuracy. Lithium fluoride (LiF) is a highly sensitive phosphor widely used for radiation dosimetry. In this work Eu activated LiF nanocubes were exposed to 85 MeV C 6+ ion beam and evaluated for their thermoluminescence (TL) response. Pellet forms of this nanomaterial were exposed to these ions in the fluence range 10 9 –10 13 ions/cm 2 . The obtained result shows a prominent TL glow peak at around 320 °C, which is different than that induced by gamma rays. This glow peak exhibits a linear response in the range 10 9 –10 12 ions/cm 2 , corresponding to the equivalent absorbed doses 0.273–273 kGy. The absorbed doses, penetration depths and main energy loss were calculated using TRIM code based on the Monte Carlo simulation. The supralinearity function and stopping power in this nanomaterial were also studied. The modification induced in the glow curve structure as a result of changing irradiation type might be utilized to use LiF:Eu nanocubes as a dosimeter for mixed filed radiations. Moreover, the wide linear response of LiF:Eu nanocubes along with the low fading are another imperative results suggesting that this nanomaterial might be a good candidate for carbon ions dosimetry

  5. Contribution to the study of the effects produced by irradiation and doping on LiF monocrystals

    International Nuclear Information System (INIS)

    Lima, Luis Filipe C.P. de

    1975-01-01

    The effects of neutron irradiation in pure and Mg doped LiF single crystals have been studied by combining internal friction and ionic thermo conductivity techniques. The main results of internal friction measurements in irradiated samples are: 1)a relaxation peak characteristic of inelastic relaxation processes is detected in pure samples exposed to fast and thermal neutrons in a swimming pool reactor. The nuclear reaction 6 Li (n,alpha)T is taken into account to explain the production of defects responsible for the detected relaxation peak because that process is not observed in experiments with pure sample shielded from thermal neutrons; 2) no Internal Friction relaxation peak is detected in Mg doped samples under the same experimental conditions; 3) It was not possible to determine an activation energy and a fundamental relaxation time for the defects responsible for the relaxation peak mentioned above because it was found that peak is not a Debye peak. Experiments, to determine the influence- of stress in Mg doped LiF crystals in torsion and in torsion-flexion configurations in the Internal Friction apparatus have also been performed. With the second experimental set-up an Internal Friction peak is detected leading to conclude that there is an Interaction between the flexion component with the Mg 2+ cation vacancy -elastic dipoles. Ionic Thermo conductivity measurements in LiF:Mg yielded for the parameters of the Mg 2+ cation vacancy pair the following values: fundamental relaxation, time τ 0 (5 +-2) x 10 -14 s and activation energy E = (0,65 + 0,02) eV. These results are in good agreement with the ones obtained In other laboratories. The effect of neutron irradiation on the concentration of Mg - cation vacancy pairs was to reduce that concentration. Moreover, two new depolarization current peaks are detected for neutron fluences higher than approximately 10 17 n/cm 2 . The relaxation parameters of one of these peaks (the lower temperature one) were

  6. Production of LiF films for dosimetric thermoluminescence application

    International Nuclear Information System (INIS)

    Mauricio, Claudia Lucia de Pinho

    2000-12-01

    This work studies the LiF monolayer and multilayer polycrystalline film's dosimetric properties. The films were produced by electron beam evaporation technique in aluminium and stainless steel substrates maintained at several temperatures. As dosimetric variable, the intensity of the thermoluminescent (TL) glow curve of the films was used. effects of the substrate type and temperature; of the addition of layers of Mg F 2 NaF and Cu F 2 to the LiF films; and of thermal treatments in the TL response of the produced films were studied. The microstructural characterization of the films was accomplished through measures of scanning electronic microscopy and grazing incidence X-rays diffraction analysis. The dosimetric characterization was made of gamma radiation exposure in a 60 Co source, with kerma from 0,1 to 500 Gy. Studies of reproducibility, homogeneity, stability and other environmental effects were also made. LiF and Cu F 2 : LiF; Mg F 2 films were the only ones that presented mechanical stability and reproducibility of the TL emission. There is a strong indication of some correlation between the residual tension fields inside the films and the intensity of its TL emission peaks. LiF monolayer films present supralinear behaviour from 0,2 to 100 Gy. These films present a main TL glow peak around 150 deg C, whose half-time is about 30 days. Its volumetric sensitivity can reach about 60 times that of LiF powder and about 0,25 that of TLD100 (LiF:Mg, Ti commercial dosimeter from Harshaw Chemical Co.) The homogeneity and reproducibility inside a same film batch is better than 12% for 95% confidence level. Cu F 2 : LiF: Mg F 2 films present linear behaviour from 3 to 500 Gy and its main TL glow peak around 200 deg C did not present any fading for a a period of 30 days, in laboratory conditions. This glow peak is characteristic of the Mg doping of LiF, which confirms the diffusion of Mg ions from the Mg F 2 layer to the LiF layer. The TL volumetric sensitivity of these

  7. Optical and ESR spectra of gamma irradiated glasses in the Ba(PO/sub 3/)/sub 2/-LiF system

    Energy Technology Data Exchange (ETDEWEB)

    Bocharova, T.V.; Karapetyan, G.O.; Khalilev, V.D.; Yashchurzhinskaya, O.A.

    1985-11-01

    This study obtains the ESR and optical absorption spectra for glasses in the Ba(PO/sub 3/)/sub 2/-LiF system. Obtaining radiation color centers (RCC) induced by ionizing radiation in alkali halide crystals (AHC), in particular LiF, has been given an enormous practical impetus according to the authors, because of the development of lasers and passive laser gates based on AHC with color centers. The glasses studied were synthesized from reagents of ''exceptionally pure'' and ''chemically pure'' grades in vitreous carbon crucibles in a dry argon atmosphere at 900-1000/sup 0/C for 60 min. followed by an anneal in a muffle at 300-450/sup 0/C. The compositions of the experimental specimens and the spectra of their optical parameters are given. The addition of up to 60 mole% of LiF does not lead to the emergence of additional absorption band (AAB) or ESR signals associated with F centers formed by gamma radiation in an LiF single crystal. As a result of gamma irradiation of glasses activated by terbium, RCC are formed which are probably electron trapping centers and correspond to the paramagnetic center (PMC).

  8. Tl response of LiF: Mg, Cu, P+Ptfe at X rays of 24, 42 and 100 KeV

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.; Tovar M, V.M.; Azorin N, J.; Furetta, C.; Quiroz C, M.C.

    2005-01-01

    In this work the obtained results of the irradiation of thermoluminescent dosemeters (Tl) of LiF: Mg,Cu,P + Ptfe with X rays for the effective radiation energy of 24, 42 and 100 keV, in an interval of Kerma in air in the sinus of the air between 0.05 and 1.0 Gy are presented. The rate of Kerma in air was determined with an ionization chamber PTW-1152, gauged by the Laboratoire Central des Industries Electriques (LCIE). As reference commercial TLD-100 dosemeters was used. The results showed that the studied Tl dosemeters presented a lineal response in the interval of mentioned Kerma. On the other hand the estimated Kerma with the Tl dosemeter in the calibration curves for X rays, were similar to the one measured with the previously gauged ionization chamber. The Tl of LiF: Mg, Cu, P + Ptfe, developed in the ININ, are highly reliable for X-ray dosimetry. (Author)

  9. Preliminary assessment of LiF and alanine detectors for the dosimetry of proton therapy beams

    International Nuclear Information System (INIS)

    Fattibene, P.; Calicchia, A.; De Angelis, C.; Onori, S.; Egger, E.

    1996-01-01

    An experimental intercomparison between the proton response of LiF TLD-100 and alanine detectors is reported. The investigations were performed with LiF chips and alanine pellets in a 62 MeV proton beam at the Paul Scherrer Institut in Villigen (CH). Results were compared with reference dosimetry provided by Markus type parallel plate ionization chamber. The response of the detectors was studied, in a phantom, at different beam penetration depths in pristine and modulated beams. For both alanine and TL detectors, within the experimental uncertainty of the measurements, no significant energy dependence in the response was observed down to the Bragg peak region. The sensitivity of alanine and LiF detectors to protons was measured in the centre of modulated Bragg peak and no significant difference was found with respect to 60 Co. Contrary to LiF, alanine also offers a remarkable tissue equivalence which favours its choice for in-phantom dosimetry. (author)

  10. Tl response of LiF: Mg, Cu, P+Ptfe at X rays of 24, 42 and 100 KeV; Respuesta TL de LiF: Mg, Cu, P+Ptfe a rayos X de 24, 42 y 100 KeV

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez M, P.R.; Tovar M, V.M. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Azorin N, J. [UAM-I, 09340 Mexico D.F. (Mexico); Furetta, C. [Universita degli Studi di Roma ' La Sapienza' , Piazzale Aldo Moro 2, 00185 Roma (Italy); Quiroz C, M.C. [Facultad de Medicina, UAEM, 50180 Toluca, Estado de Mexico (Mexico)

    2005-07-01

    In this work the obtained results of the irradiation of thermoluminescent dosemeters (Tl) of LiF: Mg,Cu,P + Ptfe with X rays for the effective radiation energy of 24, 42 and 100 keV, in an interval of Kerma in air in the sinus of the air between 0.05 and 1.0 Gy are presented. The rate of Kerma in air was determined with an ionization chamber PTW-1152, gauged by the Laboratoire Central des Industries Electriques (LCIE). As reference commercial TLD-100 dosemeters was used. The results showed that the studied Tl dosemeters presented a lineal response in the interval of mentioned Kerma. On the other hand the estimated Kerma with the Tl dosemeter in the calibration curves for X rays, were similar to the one measured with the previously gauged ionization chamber. The Tl of LiF: Mg, Cu, P + Ptfe, developed in the ININ, are highly reliable for X-ray dosimetry. (Author)

  11. Elastic atomic displacements and color center creation in LiF crystals irradiated with 3-, 9- and 12-MeV Au ions

    International Nuclear Information System (INIS)

    Sorokin, M.V.; Papaleo, R.M.; Schwartz, K.

    2009-01-01

    Creation of color centers in LiF under irradiation with 3-12-MeV Au ions was studied. Comparison of experimental data of color center creation with computer simulation of the energy deposition and elastic atomic displacements reveals the role of elastic collisions in defect creation by these ions, which have comparable magnitudes of electronic and elastic stopping. The experimentally measured efficiency of color center creation and that predicted by the simulation of elastic displacements have a similar dependence on the projectile energy. Thus, the color center creation is mainly associated with the elastic collisions, despite the relatively large values of the electronic stopping power for these ions. (orig.)

  12. Use of MCNP to compare the response of dose deposited in the TLD 100, TLD 600 and TLD 700 in radiation fields due to {sup 60}Co and {sup 241}AmBe source; Uso do MCNP para comparacao das respostas de dose depositada nos TLD 100, TLD 600 e TLD 700 em campos de irradiacao devido a fontes de {sup 60}Co e {sup 241}AmBe

    Energy Technology Data Exchange (ETDEWEB)

    Cavalieri, Tassio A.; Castro, Vinicius A.; Siqueira, Paulo T.D., E-mail: tassio.cavalieri@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2012-08-15

    The successes of Boron Neutron Capture Therapy (BNCT) depend on the ability to deliver an adequate irradiation field to the target cells. Neutron beams used in BNCT are mostly driven from reactors and therefore, not only have a neutron energy range which far exceeds the thermal region but also do have a great gamma component. Beam characterization and dosimetry are consequently one of the essential procedures to be overcome to properly apply this technique. One of the methods currently used in mixed field (field containing both neutron and gamma) characterization, lies on the use of a pair of detectors with distinct responses to each beam component. But this technique needs to be better understood of how each thermoluminescent dosimeter (TLD) behaves in a mixed field or in a pure field. This work presents the results of a set of simulations performed in order to analyze the response of three ordinary types of TLDs - TLD 100, TLD 600 and TLD 700 - submitted to different irradiation fields from a Cobalt source and an Americium-Beryllium source inside a paraffin disk. And is also a possible method for performing the selection and calibration of theses TLDs. (author)

  13. Characterization of TLD-100 in powders for dosimetric quality control of 192 Ir sources used in brachytherapy of high dose rate

    International Nuclear Information System (INIS)

    Loaiza C, S.P.

    2007-01-01

    The Secondary Standard Dosimetric at the National Institute of Nuclear Research (ININ) calibrated a lot of powdered TLD-100 (LiF:Mg,Ti) in terms of absorbed dose to water D w for the energy of: 60 Co, 137C s, X rays of 250 and 50 kVp. Later on, it is carried out an interpolation of the calibration for the energy of the 192 Ir. This calibration is part of a dosimetric quality control program, to solve the problems of traceability for the measurements carried out by the users of 192 Ir sources employed in the treatments of High Dose Rate Brachytherapy (HDR) at the Mexican Republic. The calibrations of the radiation beams are made with the following protocols: IAEA TRS-398 for the 60 Co for D w , using a secondary standard ionization chamber PTW N30013 calibrated in D w by the National Research Council (NRC, Canada). AAPM TG-43 for D w in terms of the strength kerma Sk, calibrating this last one quantity for the 137 Cs radioactive source, with a well chamber HDR 1000 PLUS traceable to the University of Wisconsin (US). AAPM TG-61 for X ray of 250 and 50 kVp for D w start to Ka using field standard a Farmer chamber PTW 30001 traceable to K for the Central Laboratory of Electric Industries (CLEI, France). The calibration curves (CC) they built for the response of the powder TLD: R TLD vs D w : For the energy of 60 Co, 137 Cs, X rays of 250 and 50 kVp. Fitting them with the least square method weighed by means of a polynomial of second grade that corrects the supra linearity of the response. iii. Each one of the curves was validated with a test by lack of fitting and for the Anderson Darling normality test, using the software MINITAB in both cases. iv. The sensibility factor (F s ) for each energy corresponds to the slope of the CC, v. The F s for the two 192 Ir sources used are interpolated: one for a Micro Selectron source and the other one a Vari Source source. Finally, a couple of capsules were sent to two hospitals that have the HDR Brachytherapy with sources of 192

  14. Thermal activation energies and peak temperatures in thermoluminescence of LiF (Mg, Ti) and CaF2:Mn at low temperatures

    International Nuclear Information System (INIS)

    Jain, V.K.; Jahan, M.S.

    1987-01-01

    Low temperature thermoluminescence (TL) of LiF (TLD-100) and CaF 2 :Mn is studied. The TLD-100 is dosimetry grade LiF manufactured by Harshaw-Filtrol Partnership. It is believed that it contains about 200 ppm Mg and 7 ppm Ti as impurities. In each case the glow curve shows several peaks. Some of these peaks are quite strong and develop with dose. Others are weak. Kinetic parameters are calculated for the former using the initial rise method and Chen's modified formula. The two sets of values are found to be different. Some authors have suggested empirical formulae connecting peak temperature, T m , and activation energy, E. The empirical relations are tried for the values of E calculated, as well as those available in literature (for T m above room temperature). It is found that a fairly reasonable relation existed between E and T m . (author)

  15. Formation of dislocations and hardening of LiF under high-dose irradiation with 5-21 MeV {sup 12}C ions

    Energy Technology Data Exchange (ETDEWEB)

    Zabels, R.; Manika, I.; Maniks, J.; Grants, R. [Institute of Solid State Physics, University of Latvia, Riga (Latvia); Schwartz, K. [GSI Helmholtzzentrum fuer Schwerionenforschung, Darmstadt (Germany); Dauletbekova, A.; Baizhumanov, M. [L.N. Gumilyov Eurasian National University, Astana (Kazakhstan); Zdorovets, M. [Institute of Nuclear Physics, Almaty (Kazakhstan)

    2017-05-15

    The emergence of dislocations and hardening of LiF crystals irradiated to high doses with {sup 12}C ions have been investigated using chemical etching, AFM, nanoindentation, and thermal annealing. At fluences ensuring the overlapping of tracks (Φ ≥6 x 10{sup 11} ions/cm{sup 2}), the formation of dislocation-rich structure and ion-induced hardening is observed. High-fluence (10{sup 15} ions/cm{sup 2}) irradiation with {sup 12}C ions causes accumulation of extended defects and induces hardening comparable to that reached by heavy ions despite of large differences in ion mass, energy, energy loss, and track morphology. The depth profiles of hardness indicate on a notable contribution of elastic collision mechanism (nuclear loss) in the damage production and hardening. The effect manifests at the end part of the ion range and becomes significant at high fluences (≥10{sup 14} ions/cm{sup 2}). (orig.)

  16. Production of LiF films for dosimetric thermoluminescence application; Producao de filmes de LiF para aplicacao em dosimetria termoluminescente

    Energy Technology Data Exchange (ETDEWEB)

    Mauricio, Claudia Lucia de Pinho

    2000-12-01

    This work studies the LiF monolayer and multilayer polycrystalline film's dosimetric properties. The films were produced by electron beam evaporation technique in aluminium and stainless steel substrates maintained at several temperatures. As dosimetric variable, the intensity of the thermoluminescent (TL) glow curve of the films was used. effects of the substrate type and temperature; of the addition of layers of Mg F{sub 2} NaF and Cu F{sub 2} to the LiF films; and of thermal treatments in the TL response of the produced films were studied. The microstructural characterization of the films was accomplished through measures of scanning electronic microscopy and grazing incidence X-rays diffraction analysis. The dosimetric characterization was made of gamma radiation exposure in a {sup 60} Co source, with kerma from 0,1 to 500 Gy. Studies of reproducibility, homogeneity, stability and other environmental effects were also made. LiF and Cu F{sub 2}: LiF; Mg F{sub 2} films were the only ones that presented mechanical stability and reproducibility of the TL emission. There is a strong indication of some correlation between the residual tension fields inside the films and the intensity of its TL emission peaks. LiF monolayer films present supralinear behaviour from 0,2 to 100 Gy. These films present a main TL glow peak around 150 deg C, whose half-time is about 30 days. Its volumetric sensitivity can reach about 60 times that of LiF powder and about 0,25 that of TLD100 (LiF:Mg, Ti commercial dosimeter from Harshaw Chemical Co.) The homogeneity and reproducibility inside a same film batch is better than 12% for 95% confidence level. Cu F{sub 2} : LiF: Mg F{sub 2} films present linear behaviour from 3 to 500 Gy and its main TL glow peak around 200 deg C did not present any fading for a a period of 30 days, in laboratory conditions. This glow peak is characteristic of the Mg doping of LiF, which confirms the diffusion of Mg ions from the Mg F{sub 2} layer to the LiF

  17. Thermoluminescence of LiF: Mg, Ti between 77 and 315 K

    International Nuclear Information System (INIS)

    Rosa, L.A.R. da.

    1989-01-01

    A special thermoluminescent system was developed. It is able to operate right from liquid nitrogen temperature and also permits the determination of the sample thermoluminescent emission spectrum. Using this system, the thermoluminescence displayed by 77 K irradiated LiF:Mg,Ti (TLD-100), from the irradiation temperature to 315 K, was studied. In this temperature range seven glow peaks, at 139, 153, 194, 240, 260, 283 and 300 K, were determined. (author)

  18. Characterization of TLD-100 in powders for dosimetric quality control of {sup 192} Ir sources used in brachytherapy of high dose rate; Caracterizacion de TLD-100 en polvo para control de calidad dosimetrico de fuentes de Ir{sup 192} usadas en braquiterapia de alta tasa de dosis

    Energy Technology Data Exchange (ETDEWEB)

    Loaiza C, S.P

    2007-07-01

    The Secondary Standard Dosimetric at the National Institute of Nuclear Research (ININ) calibrated a lot of powdered TLD-100 (LiF:Mg,Ti) in terms of absorbed dose to water D{sub w} for the energy of: {sup 60}Co, {sup 137C}s, X rays of 250 and 50 kVp. Later on, it is carried out an interpolation of the calibration for the energy of the {sup 192}Ir. This calibration is part of a dosimetric quality control program, to solve the problems of traceability for the measurements carried out by the users of {sup 192}Ir sources employed in the treatments of High Dose Rate Brachytherapy (HDR) at the Mexican Republic. The calibrations of the radiation beams are made with the following protocols: IAEA TRS-398 for the {sup 60}Co for D{sub w}, using a secondary standard ionization chamber PTW N30013 calibrated in D{sub w} by the National Research Council (NRC, Canada). AAPM TG-43 for D{sub w} in terms of the strength kerma Sk, calibrating this last one quantity for the {sup 137}Cs radioactive source, with a well chamber HDR 1000 PLUS traceable to the University of Wisconsin (US). AAPM TG-61 for X ray of 250 and 50 kVp for D{sub w} start to Ka using field standard a Farmer chamber PTW 30001 traceable to K for the Central Laboratory of Electric Industries (CLEI, France). The calibration curves (CC) they built for the response of the powder TLD: R{sub TLD} vs D{sub w}: For the energy of {sup 60}Co, {sup 137}Cs, X rays of 250 and 50 kVp. Fitting them with the least square method weighed by means of a polynomial of second grade that corrects the supra linearity of the response. iii. Each one of the curves was validated with a test by lack of fitting and for the Anderson Darling normality test, using the software MINITAB in both cases. iv. The sensibility factor (F{sub s}) for each energy corresponds to the slope of the CC, v. The F{sub s} for the two {sup 192}Ir sources used are interpolated: one for a Micro Selectron source and the other one a Vari Source source. Finally, a couple of

  19. Application of the Cavity theory in the calibration of the powder TLD-100 for energies of 60 Co, 137 Cs, 192 Ir and RX 50, 250 k Vp

    International Nuclear Information System (INIS)

    Loaiza C, S.P.; Alvarez R, J.T.

    2006-01-01

    A powder lot TLD-100 (LiF:Mg,Ti) in absorbed dose terms in water D w for the following radiation sources: 60 Co, 137 Cs and RX 50 and 250 k Vp is calibrated; to continuation is made a lineal interpolation of the TLD response in function of the effective energy of the sources to calibrate a source of 192 Ir. The calibration of those fields in D w are carried out with aid of the Bragg-Gray cavity theory, the one which finds implicit in the following protocols: IAEA-TRS 398 for the 60 Co and the AAPM TG61 for X Rays of 50 and 250 k Vp. Additionally the AAPM protocol TG43 to determine the D w in function of the kerma intensity S k in the case of the 137 Cs is used. The calibration curves for the response of the TLD-100 R TLD vs D w , corresponding to each one of the sources already mentioned are constructed. The R TLD vs D w by least heavy square by means of a second order polynomial that corrects the supralineality of the response is adjusted. The curves are validated by lack of LOF adjustment and by the Anderson Darling normality test. Later the factors of sensitivity (F s ) for the sources of 192 Ir: Micro Selectron and Vari Source are interpolated, used respectively in the A and B hospitals for treatments of brachytherapy of high dose rate (HDR), the expanded uncertainties associated to the D w and F s are also determined. Finally, an acrylic phantom and a couple of capsules are already sent to the hospitals mentioned, to verify a nominal D w of 2 Gy, in a case an underestimate in 5.5% in the imparted D w and in other an overestimation in a range of -1.5 to -8.0% was obtained. The obtained results in this work establish the bases for the development of a national dosimetric quality control program for brachytherapy of HDR with sources of 192 Ir. (Author)

  20. Measurement of the Dose to the Family Members Taking Care of Thyroid Cancer Patients Undergoing I-131 Therapy in Nuclear Medicine Using TLD-100.

    Science.gov (United States)

    Zehtabian, M; Dehghan, N; Danaei Ghazanfarkhani, M; Haghighatafshar, M; Sina, S

    2017-05-01

    The family members or friends of the patients undergoing treatment using radioiodine in nuclear medicine are inevitably exposed to ionization radiation. The purpose of this study is measurement of the dose received by the people taking care of the thyroid cancer patients treated by 131I. For this purpose, the dose amounts received by 29 people accompanying patients were measured using thermoluminescence dosimeters. A badge containing three TLD-100 chips was given to each caregiver. The people were asked to wear the badges for 24 days, when they are taking care of the patients. Finally the dose to each person was estimated by averaging the readings of the three TLDs. The measured dose amounts to the people were compared with the recommendations of international commitions. According to the results obtained in this study, the amounts of dose received by the caregivers were between 0.03 and 0.38 mSv, with the average of 0.12 mSv. By comparison of the results of this study with the recommendations of International Commission on Radiological Protection (ICRP), it can be observed that the dose to family members of the patients is less than the dose constraints. However, it is recommended that the caregivers be aware of the radiation protection principles in order to reduce their dose. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Measurement of the dose to the family members taking care of thyroid cancer patients undergoing I-131 therapy in nuclear medicine using TLD-100

    International Nuclear Information System (INIS)

    Zehtabian, M.; Dehghan, N.; Danaei Ghazanfarkhani, M.; Haghighatafshar, M.; Sina, S.

    2017-01-01

    The family members or friends of the patients undergoing treatment using radioiodine in nuclear medicine are inevitably exposed to ionization radiation. The purpose of this study is measurement of the dose received by the people taking care of the thyroid cancer patients treated by "1"3"1I. For this purpose, the dose amounts received by 29 people accompanying patients were measured using thermoluminescence dosimeters. A badge containing three TLD-100 chips was given to each caregiver. The people were asked to wear the badges for 24 days, when they are taking care of the patients. Finally the dose to each person was estimated by averaging the readings of the three TLDs. The measured dose amounts to the people were compared with the recommendations of international commissions. According to the results obtained in this study, the amounts of dose received by the caregivers were between 0.03 and 0.38 mSv, with the average of 0.12 mSv. By comparison of the results of this study with the recommendations of International Commission on Radiological Protection (ICRP), it can be observed that the dose to family members of the patients is less than the dose constraints. However, it is recommended that the caregivers be aware of the radiation protection principles in order to reduce their dose. (authors)

  2. Mensuration of equivalent dose with personal dosemeters and instruments of radiological protection in the new operative quantities ICRU, for external fields of beta radiation. Part II. I study of the angular response of personal dosemeters TLD-100 in secondary patron fields of beta radiation ({sup 90}Sr / {sup 90}Y); Medicion de dosis equivalente con dosimetros personales e instrumentos de proteccion radiologica en las nuevas magnitudes operativas ICRU, para campos de radiacion beta externos. Parte II. Estudio de la respuesta angular de dosimetros personales TLD-100 en campos patrones secundarios de radiacion beta ({sup 90}Sr/{sup 90}Y)

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J.T. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1994-01-15

    The objective of this work is to carry out one of the possible ones test type for personal dosemeters TLD, under the recomendations of the ICRU 39, ICRU 43 and the draft of the norm ISO 6980,(1992), with the purpose of verifying the capacity of these detectors to carry out the operative unit: H' (0.07;{alpha}). Since H' (O. 07;{alpha}) this defined one in an expanded field, one of these tests type consist on determining the angular response of these detectors. 20 personal dosemeters TLD-100 was used, (card marks: Harshaw, Model: G-1, with two glasses of TLD-100 absorbed in teflon; the portadosemeters has two windows, a free one and another with a filter of Pb of 171.0 mg cm{sup -2}); these dosemeters they were previously selected, [to see, {sup S}tudy of the Homogeneity of the response of Personal Dosemeters (Cards G-l, TLD-100) in Radiation of Countrysides of {sup 60}Co{sup ,} J.T. Alvarez R. Technician Report GSR/IT/0001/94].The irradiations to effectued in secondary countryside of radiation beta of {sup 90}Sr/{sup 90}Y. The study was undertaken by means of an experimental design of blocks random that contemplate the following variables: intensity of the radiation source, (1850 MBq and 74 MBq); position of irradiation, (four positions); incidence of angle of the radiation (0, 15, 30, 45, 60 and 75 grades) and the absorbed dose in air, (0.005, 0.010, 0.020, 0.050 and 0.100 Gy). Then null hypothesis it was to suppose that there was not difference among the stockings of each treatment, to used the statistical of Duncan to carry out tests of stockings at a level of significance of 5%.These tests of stockings throw the following results in those variables of the experimental design: The irradiations carried out so much with the source pattern secondary of {sup 90}Sr/{sup 90}Y of 1850 MBq and of 74 MBq, they are equivalent reason why they can be used indistinctly. The responses of each one of the glasses of the card are strongly anisotropic for each glass

  3. Personal dosimetry TLD 100 in orthopedic surgeons exposed to ionizing radiation in Bogota - Colombia; Dosimetria personal TLD 110 en medicos ortopedistas expuestos a radiacion ionizante en Bogota - Colombia

    Energy Technology Data Exchange (ETDEWEB)

    Sierra C, B. Y.; Jimenez, Y. [Universidad Nacional de Colombia, Departamento de Fisica, Grupo de Fisica Medica, Carrera 45 No. 26-85, Bogota (Colombia); Plazas, M. C. [Hospital Universitario Fundacion Santa Fe de Bogota, Instituto de Oncologia Carlos Ardila Lulle, Calle 119, No. 7-90, 220246 Bogota (Colombia); Eslava S, J. [Universidad Nacional de Colombia, Instituto de Investigaciones Clinicas, Grupo Equidad en Salud, Carrera 45 No. 26-85, Bogota (Colombia); Groot R, H., E-mail: brigith.sierra@gmail.com [Universidad de los Andes, Laboratorio de Genetica Humana, Carrera 1 No. 18A -12, Bogota (Colombia)

    2014-08-15

    Orthopedic surgeons should be considered as professionals occupationally exposed to ionizing radiation, for using C arc (fluoroscope) an equipment of X type radiation emission, during surgical procedures for imaging generation. Some health institutes, use of C arc under uncontrolled circumstances, such a lack of dosimetry control, incomplete or absence of personnel protective elements and protective measures, which in turn, lead to a high exposition to the personnel. Materials and methods. Study of double match cohort by age and gender, was conducted, in four health institutions of second and third level of attention in Bogota city. Personal dosimetry measurements with TLD-100 dosimetry crystals in both cohorts and environmental dosimetry in each of operation rooms used for orthopedic procedures, were carry out during six months of follow up. Dosimetry crystals were read in a Harshaw 4500 - Bicron equipment, in the Medical Physics Laboratory of National University of Colombia. Results. Dosimetry measurements are compatibles with those of occupationally exposed personnel 3.44 mSv/6 m CI 95% (1.66-3.99), even does not overpass ICRP recommendations, are higher as were expect at the beginning of the study. The median of effective accumulative dose in thorax is 3,4 mSv CI 95% (1,66-3,99), higher in comparison with neck value 2,7 mSv CI 95% (1,73-3,80) and hand dosimetry 1,42 mSv CI 95% (0,96-2,34). Conclusions: Orthopedic surgeons should be considered occupational exposed to ionizing radiation, who has to accomplish to the radiological protection measures, dosimetric follow up and maintenance of the used X ray equipment. It was confirm throughout this study that dosimetry shows higher levels as expected at the beginning of the study, compatible with occupationally exposed personnel. (Author)

  4. The effect of sample/planchet geometry and temperature resolution on the reproducibility of glow curve shapes and precision of dose measurement in LiF-TLD-100 thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Sibony, D.; Horowitz, Y.; Oster, L.

    2014-01-01

    The effect of accurate positioning of TLD-100 samples in the center of the reader planchet on precision and kinetic parameters was investigated. Significant improvement in precision is obtained by careful positioning of the sample in the center of the planchet, by as much as 40%, 20% and 30% using different methods of glow curve analysis to estimate the intensity of the TL signal. - Highlights: • The effect of accurate positioning of TLD-100 samples on precision and kinetic parameters was investigated. • Significant improvement in precision was obtained. • Significant improvement in the calculation of the kinetic parameters of individual peaks was achieved. • The optimum protocol involves a depression matched to the size of the sample was developed

  5. Mensuration of equivalent dose with personal dosemeters and instruments of radiological protection in the new operative quantities ICRU, for external fields of beta radiation. Part II. I study of the angular response of personal dosemeters TLD-100 in secondary patron fields of beta radiation (90Sr / 90Y)

    International Nuclear Information System (INIS)

    Alvarez R, J.T.

    1994-01-01

    The objective of this work is to carry out one of the possible ones test type for personal dosemeters TLD, under the recomendations of the ICRU 39, ICRU 43 and the draft of the norm ISO 6980,(1992), with the purpose of verifying the capacity of these detectors to carry out the operative unit: H' (0.07;α). Since H' (O. 07;α) this defined one in an expanded field, one of these tests type consist on determining the angular response of these detectors. 20 personal dosemeters TLD-100 was used, (card marks: Harshaw, Model: G-1, with two glasses of TLD-100 absorbed in teflon; the portadosemeters has two windows, a free one and another with a filter of Pb of 171.0 mg cm -2 ); these dosemeters they were previously selected, [to see, S tudy of the Homogeneity of the response of Personal Dosemeters (Cards G-l, TLD-100) in Radiation of Countrysides of 60 Co , J.T. Alvarez R. Technician Report GSR/IT/0001/94].The irradiations to effectued in secondary countryside of radiation beta of 90 Sr/ 90 Y. The study was undertaken by means of an experimental design of blocks random that contemplate the following variables: intensity of the radiation source, (1850 MBq and 74 MBq); position of irradiation, (four positions); incidence of angle of the radiation (0, 15, 30, 45, 60 and 75 grades) and the absorbed dose in air, (0.005, 0.010, 0.020, 0.050 and 0.100 Gy). Then null hypothesis it was to suppose that there was not difference among the stockings of each treatment, to used the statistical of Duncan to carry out tests of stockings at a level of significance of 5%.These tests of stockings throw the following results in those variables of the experimental design: The irradiations carried out so much with the source pattern secondary of 90 Sr/ 90 Y of 1850 MBq and of 74 MBq, they are equivalent reason why they can be used indistinctly. The responses of each one of the glasses of the card are strongly anisotropic for each glass; four positions of irradiation is used: glass 1 (window of

  6. Dosimetric characterization of a Tl new material of LiF: Mg, Cu, P; Caracterizacion dosimetrica de un nuevo material TL de LiF: Mg, Cu, P

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, P.R.; Avila, O. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Quiroz, C. [UAEM, Facultad de Medicina, 50180, Toluca, Estado de Mexico (Mexico); Azorin, J. [UAM-I, 09340 Mexico D.F. (Mexico)

    2004-07-01

    In this work the method of preparation of a new material T L is described of LiF: Mg, Cu, P and the preliminary results of the tests corresponding to their dosimetric characterization are reported. The carried out tests were: detection threshold, sensitivity, dissipation of the sign T L, answer T L in function of the dose of radiation gamma, among others. The results showed that this material when receiving the one thermal treatment of having erased of 280 C by 10 min, followed by 100 C for two hours, he/she has a detection threshold ten times but I lower that that of the TLD-100, is 21 times but sensitive that that of reference and the dissipation of the sign T L during two months was null. This new material T L overcomes in many aspects to the commercial dosemeters of its type. (Author)

  7. Elaboration of pellets of LiF: Mg, Cu, P and its dosimetric properties; Elaboracion de pastillas de LiF: Mg, Cu, P y sus propiedades dosimetricas

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez C, A.; Gonzalez M, P.R.; Azorin N, J

    1991-03-15

    The LiF: Mg, Cu, P is at the moment in the entire world one of the TL materials of more interest, by its equivalence with the tissue, as well as for its high sensitivity, which is 25 to 35 times greater than of the TLD-100 of Harshaw (USA). In our laboratory dosemeters of this material have been developed in form of sinterized pellets. The importance of these new dosemeters in pellet form is due to that in this form its manipulation is facilitated. Due to its high sensitivity, these dosemeters result to be those but appropriate to measure the ionizing radiations, in intervals of extremely low dose. In this report the method of elaboration of the pellets, as well as its main dosimetric characteristics are presented. (Author)

  8. Influence of heavy ion implantation on the microhardness of lif

    CERN Document Server

    Abu-Alazm, S M

    2003-01-01

    The paper presented microhardness measurements for pure lithium fluoride (LiF) implanted with Ar, Kr and Xe at doses ranged from 10 sup 9 up to 10 sup 1 2 ion/cm sup 2. Measurements were also performed for the microhardness after irradiation by electron and gamma rays. The data exhibited a large increase of microhardness of LiF using heavy ions in comparison with the unimplanted and irradiated samples with electrons and gamma rays. The influence of annealing the samples on the microhardness is also studied. The obtained results were interpreted according to the formation of F-centers in LiF.

  9. Dosimetric characterization of a Tl new material of LiF: Mg, Cu, P

    International Nuclear Information System (INIS)

    Gonzalez, P.R.; Avila, O.; Quiroz, C.; Azorin, J.

    2004-01-01

    In this work the method of preparation of a new material T L is described of LiF: Mg, Cu, P and the preliminary results of the tests corresponding to their dosimetric characterization are reported. The carried out tests were: detection threshold, sensitivity, dissipation of the sign T L, answer T L in function of the dose of radiation gamma, among others. The results showed that this material when receiving the one thermal treatment of having erased of 280 C by 10 min, followed by 100 C for two hours, he/she has a detection threshold ten times but I lower that that of the TLD-100, is 21 times but sensitive that that of reference and the dissipation of the sign T L during two months was null. This new material T L overcomes in many aspects to the commercial dosemeters of its type. (Author)

  10. Application of cavity theories to high-energy response of LiF dosimeters

    International Nuclear Information System (INIS)

    Ogunleye, O.T.; Fregene, A.O.

    1981-01-01

    The relative energy response of 0.4- and 1.16-mm thick LiF TLD-100 showed decreases of 5 and 9%, respectively, for 22-MV x rays and 6-, 9-, 12-, 15-, and 18-MeV electron energies when compared to responses for 60 Co γ rays in polystyrene and water media. The theories of Burlin, Burlin et al., Almond and McCray, and Holt et al. do not agree with these findings. Reasonable agreement is obtained with the Fregene expression and with Almond and McCray and Holt et al. only when the photon energy response at 60 Co is calculated from the Fregene expression. The hitherto conflicting results are resolved where sufficient experimental and theoretical details are given in light of the present findings

  11. Elaboration of pellets of LiF: Mg, Cu, P and its dosimetric properties

    International Nuclear Information System (INIS)

    Gutierrez C, A.; Gonzalez M, P.R.; Azorin N, J.

    1991-03-01

    The LiF: Mg, Cu, P is at the moment in the entire world one of the TL materials of more interest, by its equivalence with the tissue, as well as for its high sensitivity, which is 25 to 35 times greater than of the TLD-100 of Harshaw (USA). In our laboratory dosemeters of this material have been developed in form of sinterized pellets. The importance of these new dosemeters in pellet form is due to that in this form its manipulation is facilitated. Due to its high sensitivity, these dosemeters result to be those but appropriate to measure the ionizing radiations, in intervals of extremely low dose. In this report the method of elaboration of the pellets, as well as its main dosimetric characteristics are presented. (Author)

  12. The characteristics of CaF2:Tm crystals (TLD-300) irradiated by electromagnetic radiation

    International Nuclear Information System (INIS)

    Ben-Shachar, B.; Yona, S.; Laichter, Y.; German, U.; Weiser, G.

    1985-09-01

    The main characteristics of the CaF 2 :Tm crystals (TLD-300), as a dosimeter, were measured: the glow curve, sensitivity, linearity, fading and energy dependence for photons, and compared to those of LiF (TLD-100) and CaF 2 :Dy (TLD-200). It was found that CaF 2 :Tm can be used for environmental dosimetry by reading the crystals after four days. (Author)

  13. Optimization of the preparation method of LiF: Mg, Cu, P and study of its thermoluminescent properties to be used in ionizing radiation dosimetry

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.

    1995-01-01

    In this thesis the preparation and dosimetric properties of the thermoluminescence phosphor LiF doped with magnesium, copper and phosphorus are studied. In chapter 1 luminescence phenomenon in solids is described, emphasizing the importance of thermally stimulated luminescence known as thermoluminescence (TL) as well as its application in ionizing radiation dosimetry. The models used to determine the kinetics parameters in the TL phenomenon are described in chapter 2. In chapter 3, the dosimetric characteristics of a TL materials and its requirements for dosimetry are analyzed. The preparation method of LiF: Mg, Cu, P is presented in chapter 4 studying its general characteristics for dosimetry. The concentrations of dopants, glow curve structure, TL response to gamma, beta and alpha exposures are studied along with those of LiF: Mg, Cu, P prepared for other authors and with those of LiF: Mg, Ti (TLD-100). The kinetic parameters of the phosphor were determined by the deconvolution method. Pellets of this new phosphor powder were made by pressing it at room temperature and sintering in inert atmosphere at 700 Centigrade degrees. Dosimetric characteristics of these pellets were also studied. Chapter 5 presents the results and conclusions of this study. The new dosimeter exhibited three peaks in its glow curve at 140, 180 and 220 Centigrade degrees respectively. Its TL response to gamma radiation was linear from 43.5 μ Gy to 100 Gy. This dosimeter is reusable and stable without significant loss of sensitivity. Its sensitivity was about 30 times higher than that of TLD-100. Fading of this dosimeter was negligible at room temperature as well as at body temperature (37 Centigrade degrees), and 65% at 60 Centigrade degrees. In conclusion, this dosimeter meets all the requirements of the ANSI standard. These and other characteristics render this dosimeter useful in diverse applications of radiation dosimetry. (Author)

  14. LIF standoff research

    International Nuclear Information System (INIS)

    Olson, C.L.; Cuneo, M.E.; Desjarlais, M.P.; Filuk, A.B.; Hanson, D.L.; Lockner, T.R.; Hinshelwood, D.D.; Hubbard, R.F.; Lampe, M.; Greenly, J.B.

    1994-01-01

    Present LIF target experiments on PBFA II use a barrel diode in which the total transport length from the anode to the target is ≤ 15 cm. Future LIF development includes high yield applications (LMF) and energy production (ETF and LIBRA power plants) that require standoff - the generation of extracted ion beams and transport of these beams over distances of several meters. Standoff research includes the development of high efficiency extraction diodes (single stage and two-stage), improvements in beam quality (divergence, purity, uniformity, etc.), and the efficient transport and focusing of these beams over distances of several meters to a fusion target. Progress in all of these areas is discussed, as well as a strategy to reduce the divergence from the present 17 mrad for 5 MeV protons on SABRE to the required mrad for 35 MeV Li ions for LMF. The status of experiments is summarized, and future directions are indicated

  15. The influence of thyroid geometry on the response of LiF and CaSO4 thermoluminescent discs to 131I and 125I irradiation

    International Nuclear Information System (INIS)

    O'Connor, M.K.; Malone, J.F.; Cullen, M.J.

    1978-01-01

    Recent work has demonstrated that LiF and CaSO 4 thermoluminescent discs may be used to monitor the effective half-life of radioiodine in the thyroid in man. To provide a firm basis for the work, the radiation field presented by model thyroids to thermoluminescent discs on the surface of a neck phantom has been examined in detail. The influence of thyroid mass, depth and lobe separation, factors which in practice are highly variable, has also been determined. The results demonstrate that the method is sufficiently sensitive to measure less than 0.5 μCi of 131 I or 125 I in the human thyroid, and that effective half-life determinations should not be influenced by minor positioning errors which may be encountered when placing thermoluminescent discs on the neck surface. (author)

  16. Detection of irradiated foods by the thermoluminescence. Relationships between the temperature ranges of integrating TL glow curves and TL glow ratios

    International Nuclear Information System (INIS)

    Sekiguchi, Masayuki; Yamazaki, Masao; Goto, Michiko; Todoriki, Setsuko; Hagiwara, Shoji

    2007-01-01

    Our study demonstrated that the effects of the several temperature ranges for integrating TL glow intensity on the TL glow ratios by using spice-set purchased at a Turkish air port. The spice set had no labeling of irradiation feeds, but nine of 12 spices were judged as irradiated food in this study. Those temperature ranges were defined by evaluating the glow curves of irradiated TLD-100 chip (167-230degC), TLD-100 disc (177-238degC) and Dolomite element (145-258degC). Those are relatively stable and the difference of typical glow peak temperatures of TLD-100 disc in two institutes was less than 2%. On the other hand, those of TLD-100 tip was shift to higher temperature side at about 4degC because of declining of thermal conductance. The temperature ranges defined by TLD-100 were showed that discriminate more clearly between irradiated and nonirradiated spices compared with the full temperature range of TL measurement (70-400degC). With the exception of low glow intensity, background measurement for estimating net glow intensity was not necessary because TL glow ratio was hardly influenced whether the background measured or not. (author)

  17. Radiation-Induced Color Centers in LiF for Dosimetry at High Absorbed Dose Rates

    DEFF Research Database (Denmark)

    McLaughlin, W. L.; Miller, Arne; Ellis, S. C.

    1980-01-01

    Color centers formed by irradiation of optically clear crystals of pure LiF may be analyzed spectrophotometrically for dosimetry in the absorbed dose range from 102 to 107 Gy. Routine monitoring of intense electron beams is an important application. Both 6LiF and 7LiF forms are commercially...... available, and when used with filters as albedo dosimeters in pairs, they provide discrimination of neutron and gamma-ray doses....

  18. Pre- and post-irradiation fading effect for LiF:Mg,Ti and LiF:Mg,Cu,P materials used in routine monitoring

    International Nuclear Information System (INIS)

    Carinou, E.; Askounis, P.; Dimitropoulou, F.; Kiranos, G.; Kyrgiakou, H.; Nirgianaki, E.; Papadomarkaki, E.; Kamenopoulou, V.

    2011-01-01

    LiF is a well-known thermoluminescent (TL) material used in individual monitoring, and its fading characteristics have been studied for years. In the present study, the fading characteristics (for a period of 150 d) of various commercial LiF materials with different dopants have been evaluated. The materials used in the study are those used in routine procedures by the Personal Dosimetry Dept. of Greek Atomic Energy Commission and in particular, LiF:Mg,Ti (MTS-N, TL Poland), LiF:Mg,Cu,P (MCP-N, TL Poland), LiF:Mg,Cu,P (MCP-Ns, thin active layer detector, TL Poland) and LiF:Mg,Cu,P (TLD100H, Harshaw). The study showed that there is a sensitivity loss in signal of up to 20 % for the MTS-N material for a 150-d period in the pre-irradiation fading phase. The MCP-N has a stable behaviour in the pre-irradiation fading phase, but this also depends on the readout system. As far as the post-irradiation fading effect is concerned, a decrease of up to 20 % for the MTS-N material is observed for the same time period. On the other hand, the LiF:Mg,Cu,P material presents a stable behaviour within ±5 %. These results show that the fading effect is different for each material and should be taken into account when estimating doses from dosemeters that are in use for >2 months. (authors)

  19. Energy dependence of the supralinearity (f(D)max) of peaks 7 and 8 in the high temperature thermoluminescence of LiF:Mg,Ti (TLD-100) : Interpretation using the Unified Interaction Model

    International Nuclear Information System (INIS)

    Datz, H.; Horowitz, Y.S.; Epstein, L.; Oster, L.; Livingstone, J.; Horowitz, A.; Kol, M.; Margaliot, M.

    2011-01-01

    It is demonstrated that the supralinearity of the dose response of glow peaks 7, 8 in the glow curve of LiF:Mg,Ti (TLD-100) are very strongly dependent on photon/electron energy. Previously published data on f(D) max at photon energies of 1.25 MeV, 100 keV and 8.1 keV effective energy coupled with new data at ∼ 540 keV using 90 Sr/ 90 Y beta rays reveals that the maximum supralinearity f(D) max decreases from values of ∼200 and ∼30 at 1.25 MeV, through intermediate values at 540 keV and 100 keV, to values of ∼ 30 and ∼3 at 8.1 keV effective energy. The normalized dose response f(D) for all energies is modeled using the Unified Interaction Model and the dependence of f(D) max on energy is interpreted as arising from strong dependence of the relative intensity of localized recombination on particle energy (ionization density).

  20. Synthesis and characterization of europium doped LiF phosphor

    Energy Technology Data Exchange (ETDEWEB)

    Villalobos, M. L.; Vallejo, M. A.; Sosa A, M. [Universidad de Guanajuato, Division de Ciencias e Ingenierias, Loma del Bosque No. 103, Lomas del Campestre, 37150 Leon, Guanajuato (Mexico); Diaz T, L. A., E-mail: villaloboscm2010@licifug.ugto.mx [Centro de Investigaciones en Optica, A. C., Loma del Bosque No. 115, Lomas del Campestre, 37150 Leon, Guanajuato (Mexico)

    2015-10-15

    LiF with different dopants has been one of the most investigated materials to use as thermoluminescent dosimeter. In this paper, we present the preparation method, the characterization and the thermoluminescent response of Eu doped LiF irradiated with X-rays. Pure and Eu doped LiF samples with different dopant concentration (0, 0.25, 0.5, 0.75 and 1 % mol) were synthesized using the precipitation method. The samples were structurally characterized by X-ray diffraction (XRD), the diffraction patterns showed a main cubic crystalline structure and a secondary hexagonal structure. The photoluminescence spectrum exhibited four well defined peaks characteristic of the Eu{sup 3+} ion. Thermoluminescent (Tl) glow curves of x-ray irradiated samples showed a well-defined single peak around 200 degrees C, except for the pure and 0.25% Eu doped samples. (Author)

  1. Mensuration of equivalent dose with personal dosemeters and instruments of radiological protection in the new operative magnitudes ICRU, for external fields of beta radiation. Part I. Study of the homogeneity of the response personal dosemeters leaves (cards G-1, TLD-100), in radiation fields of Co{sub 60}; Medicion de dosis equivalente con dosimetros personales e instrumentos de proteccion radiologica en las nuevas magnitudes operativas ICRU, para campos de radiacion beta externos. Parte I. Estudio de la homogeneidad de la respuesta dosimetros personales (tarjetas G-1, TLD-100), en campos de radiacion de Co{sub 60}

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J.T. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1994-01-15

    A sample of 40 composed personal dosemeters by cards model: G-l, (each card is made up of two TLD-100 crystals encapsulated in teflon), Harshaw trademark; those personal dosemeters present a free window and another with a filter of A1 of 171.7 mg cm{sup -2} of mass thickness.The objective of the work is to select of this sample of 40 personal dosemeters a population with the same stocking and standard deviation. The technique used is that of comparison of stockings, (ANOVA; Variance Analysis, when samples of the same one were had size; and/or GLM, Widespread Lineal Models, when the samples were of different size), by means of the use of those Duncan statistics, SNK, Tukey, Gabriel; the results are validated proving the kindness of adjustment of the experimental data to a Normal distribution by means of the Shapiro-Wilks statistics.The experimental design used consists on a test of two vias: a via is the variable card with two levels, (crystal 1 and 2), the other via is the variable irradiation position with four levels, (LS=left superior, SR= right superior, LI= left Inferior, IR = right inferior). The irradiations carried out in blocks of four personal dosemeters in a gamma radiation beam range of Cobalt 60; carrying out three repetitions of the design. With object of proving the homogeneity of the filter of A1 in those personal dosemeters the experimental design was executed for those cards without personal dosemeters.They were also carried out tests of stockings to the readings of bottom and sensibility of the reader equipment, (Harshaw, model marks 2271), certain that doesn{sup t} exist differences for sequence of reading, but if in the stockings of the sensibility, (they were 4 different populations). The responses of the dosemeters were corrected subtracting him the reading correspondence of bottom and by sensibility of the reader equipment before subjecting them to the tests of stockings mentioned. Of the results of the tests of stockings for the cards with

  2. Dosimetric properties of carbon loaded LiF detectors for beta photon extremity dosimetry

    International Nuclear Information System (INIS)

    Burgkhardt, B.; Klipfel, A.

    1990-01-01

    The dosimetric properties of carbon loaded LiF detectors manufactured by Alnor and Vinten are presented in comparison with various LiF detectors. In particular, the beta and photon response, the residual reading after repeated annealing in the oven or reader as well as light sensitivity and fading are discussed. In comparison with LiF detectors of 240 mg.cm -2 , LiF + C detectors indicate a photon response of only 2% and in finger rings irradiated on a finger phantom an unexpected high photon energy response. Regarding repeated use, oven annealing in air or N 2 affects mainly Vinten LiF + 1% C by discoloration and reduces the 147 Pm response of LiF + C detectors by between 1% and 6% per N 2 annealing, whereas reader annealing in the Toledo and Alnor reader does not affect the relative beta response. The residual dose H 0 of LiF + C remains sufficiently low after oven annealing, but increases for Alnor LiF + 4% C after reader annealing, which is therefore more suitable for Vinten LiF + 1% C. Spurious detector reading exceeds H 0 and its standard deviation by a factor of 2 to 3. (author)

  3. Numerical analysis for complex thermoluminiscence glow curves.Application to the study of LiF: Ti, Mg and its in radiation dosimetry

    International Nuclear Information System (INIS)

    Gomez Ros, J.M.

    1989-01-01

    A method for the numerical analysis of complex termoluminiscence glow curves based in a modified Marquard Levenberg minimization algorithm is presented. Differents analytical expresions are employed for the individual glow peaks in the cases of first, second and mixed order kinetics, developping aproximated expresions for everyone. These procedures are applied to the caracterization of Lithium Fluoride studying the kinetic order of peaks IV and V. The results obtained permits an interpretation of the complex isothermal decay observed at 165 0 C compatible whith first order kinetics process for both peaks. The aplication to thermoluminiscent dosimetry (TLD) is also described. Other numerical methods are specifically developped to operate whith LiF 8TLD-100) in specific dosimetric aplications of TLD, such environ mental monitoring and mailed dosimetry systems for quality assurance in radiotherapy facilities. The reduction in the minimun detectable dose and the increment in the fiability of the meassurements are some of the advantages obtained over conventional evaluation systems. (Author)

  4. Mensuration of equivalent dose with personal dosemeters and instruments of radiological protection in the new operative magnitudes ICRU, for external fields of beta radiation. Part I. Study of the homogeneity of the response personal dosemeters leaves (cards G-1, TLD-100), in radiation fields of Co60

    International Nuclear Information System (INIS)

    Alvarez R, J.T.

    1994-01-01

    A sample of 40 composed personal dosemeters by cards model: G-l, (each card is made up of two TLD-100 crystals encapsulated in teflon), Harshaw trademark; those personal dosemeters present a free window and another with a filter of A1 of 171.7 mg cm -2 of mass thickness.The objective of the work is to select of this sample of 40 personal dosemeters a population with the same stocking and standard deviation. The technique used is that of comparison of stockings, (ANOVA; Variance Analysis, when samples of the same one were had size; and/or GLM, Widespread Lineal Models, when the samples were of different size), by means of the use of those Duncan statistics, SNK, Tukey, Gabriel; the results are validated proving the kindness of adjustment of the experimental data to a Normal distribution by means of the Shapiro-Wilks statistics.The experimental design used consists on a test of two vias: a via is the variable card with two levels, (crystal 1 and 2), the other via is the variable irradiation position with four levels, (LS=left superior, SR= right superior, LI= left Inferior, IR = right inferior). The irradiations carried out in blocks of four personal dosemeters in a gamma radiation beam range of Cobalt 60; carrying out three repetitions of the design. With object of proving the homogeneity of the filter of A1 in those personal dosemeters the experimental design was executed for those cards without personal dosemeters.They were also carried out tests of stockings to the readings of bottom and sensibility of the reader equipment, (Harshaw, model marks 2271), certain that doesn t exist differences for sequence of reading, but if in the stockings of the sensibility, (they were 4 different populations). The responses of the dosemeters were corrected subtracting him the reading correspondence of bottom and by sensibility of the reader equipment before subjecting them to the tests of stockings mentioned. Of the results of the tests of stockings for the cards with and

  5. Radiological environmental monitoring with LiF-700-H dosemeters

    International Nuclear Information System (INIS)

    Scarnichia, E.; Levanon, I.; Andres, P.; Miani, C.; Ramirez, S.

    2011-10-01

    Since 2008 a radiological environmental monitoring with LiF-700-H has been carried out as a result of increasing the Ra-6 research reactor core power. The information obtained is used to evaluate and to quantify analytically the air kerma rate, the fading and the associated uncertainty by developing software tools (deconvolution and uncertainty algorithms). LiF-700-H dosemeters were chosen because of their high sensitivity to low air kerma rates. They show a very good stability and a negligible fading for two-month working periods. The air kerma rate detection limit (based on the 3σ criterion) during these working periods is about 0.4 n Gy/h. Air kerma rates of about 70 n Gy/h are measured with this detection limit. Following the Nist guidelines, an algorithm was developed in order to find the associated uncertainty. It considers several aspects, such as the source activity decay, distance source-dosemeter during the calibration procedure, irradiation time, calibration factor, dosemeter readout, dosemeter sensitivity, TLD reader stability and fading. The associated uncertainty is found to be about 25% for a 95% confidence interval (k = 2.025), which can be considered acceptable when taking into account the very low air kerma rates estimated. The LiF-700-H response to different energies and its relationship with climate changes over the calendar year are planned as future tasks. (Author)

  6. Detection of irradiated spice in blend of irradiated and un-irradiated spices using thermoluminescence method

    International Nuclear Information System (INIS)

    Goto, Michiko; Yamazaki, Masao; Sekiguchi, Masayuki; Todoriki, Setsuko; Miyahara, Makoto

    2007-01-01

    Five blended spice sample were prepared by mixing irradiated and un-irradiated black pepper and paprika at different ratios. Blended black pepper containing 2%(w/w) of 5.4 kGy-irradiated black pepper showed no maximum at glow1. Irradiated black pepper samples, mixed to 5 or 10%(w/w), were identified as 'irradiated' or 'partially irradiated' or 'un-irradiated'. All samples with un-irradiated pepper up to 20%(w/w) were identified as irradiated'. In the case 5.0 kGy-irradiated paprika were mixed with un-irradiated paprika up to 5%(w/w), all samples were identified as irradiated'. The glow1 curves of samples, including irradiated paprika at 0.2%(w/w) or higher, exhibited a maximum between 150 and 250degC. The results suggest the existence of different critical mixing ratio for the detection of irradiation among each spices. Temperature range for integration of the TL glow intensity were compared between 70-400degC and approximate 150-250degC, and revealed that the latter temperature range was determined based on the measurement of TLD100. Although TL glow ratio in 150-250degC was lower than that of 70-400degC range, identification of irradiation was not affected. Treatment of un-irradiated black pepper and paprika with ultraviolet rays had no effect on the detection of irradiation. (author)

  7. Electron irradiation response on Ge and Al-doped SiO{sub 2} optical fibres

    Energy Technology Data Exchange (ETDEWEB)

    Yaakob, N.H.; Wagiran, H. [Department of Physics, Universiti Teknologi Malaysia, 81310 Skudai, Johor Darul Takzim (Malaysia); Hossain, I., E-mail: imamhossain@utm.m [Department of Physics, Universiti Teknologi Malaysia, 81310 Skudai, Johor Darul Takzim (Malaysia); Ramli, A.T. [Department of Physics, Universiti Teknologi Malaysia, 81310 Skudai, Johor Darul Takzim (Malaysia); Bradley, D.A [Department of Physics, University of Surrey, Guildford GU2 7XH (United Kingdom); Hashim, S. [Department of Physics, Universiti Teknologi Malaysia, 81310 Skudai, Johor Darul Takzim (Malaysia); Ali, H. [Department of Radiotherapy and Oncology, Hospital Sultan Ismail, Johor Darul Takzim (Malaysia)

    2011-05-01

    This paper describes the thermoluminescence response, sensitivity, stability and reproducibility of SiO{sub 2} optical fibres with various electron energies and doses. The TL materials that comprise Al- and Ge-doped silica fibres were used in this experiment. The TL results are compared with those of the commercially available TLD-100. The doped SiO{sub 2} optical fibres and TLD-100 are placed in a solid phantom and irradiated with 6, 9 and 12 MeV electron beams at doses ranging from 0.2 to 4.0 Gy using the LINAC at Hospital Sultan Ismail, Johor Bahru, Malaysia. It was found that the commercially available Al- and Ge-doped optical fibres have a linear dose-TL signal relationship. The intensity of TL response of Ge-doped fibre is markedly greater than that of the Al-doped fibre.

  8. Electron irradiation response on Ge and Al-doped SiO 2 optical fibres

    Science.gov (United States)

    Yaakob, N. H.; Wagiran, H.; Hossain, I.; Ramli, A. T.; Bradley, D. A.; Hashim, S.; Ali, H.

    2011-05-01

    This paper describes the thermoluminescence response, sensitivity, stability and reproducibility of SiO 2 optical fibres with various electron energies and doses. The TL materials that comprise Al- and Ge-doped silica fibres were used in this experiment. The TL results are compared with those of the commercially available TLD-100. The doped SiO 2 optical fibres and TLD-100 are placed in a solid phantom and irradiated with 6, 9 and 12 MeV electron beams at doses ranging from 0.2 to 4.0 Gy using the LINAC at Hospital Sultan Ismail, Johor Bahru, Malaysia. It was found that the commercially available Al- and Ge-doped optical fibres have a linear dose-TL signal relationship. The intensity of TL response of Ge-doped fibre is markedly greater than that of the Al-doped fibre.

  9. Electron irradiation response on Ge and Al-doped SiO2 optical fibres

    International Nuclear Information System (INIS)

    Yaakob, N.H.; Wagiran, H.; Hossain, I.; Ramli, A.T.; Bradley, D.A; Hashim, S.; Ali, H.

    2011-01-01

    This paper describes the thermoluminescence response, sensitivity, stability and reproducibility of SiO 2 optical fibres with various electron energies and doses. The TL materials that comprise Al- and Ge-doped silica fibres were used in this experiment. The TL results are compared with those of the commercially available TLD-100. The doped SiO 2 optical fibres and TLD-100 are placed in a solid phantom and irradiated with 6, 9 and 12 MeV electron beams at doses ranging from 0.2 to 4.0 Gy using the LINAC at Hospital Sultan Ismail, Johor Bahru, Malaysia. It was found that the commercially available Al- and Ge-doped optical fibres have a linear dose-TL signal relationship. The intensity of TL response of Ge-doped fibre is markedly greater than that of the Al-doped fibre.

  10. Traceability of a panoramic gamma irradiator using different TLD systems as transfer instruments

    International Nuclear Information System (INIS)

    Romero, A.M.; Saez, J.C.

    1994-01-01

    This work shows the calibration in terms of the new operational radiological quantities Hp(10) and H*(10) for different TLD systems (Harshaw TLD-100 and Panasonic UD-802) used in personal and environmental monitoring. The irradiations were performed in the Spanish Reference Laboratory in radiation protection levels, managed by the CIEMAT Metrology of ionizing radiations Unit. With these data, different calibrations of a panoramic gamma irradiator in terms of the radiological quantity for unit of time were established, providing the traceability of the irradiator to the Reference Laboratory using the corresponding TLD systems as transfer instruments. (Author) 9 refs

  11. Traceability of a panoramic gamma irradiator using different TLD systems as transfer Instruments

    International Nuclear Information System (INIS)

    Romero, A. M.; Saez, J. C

    1994-01-01

    This work shows the calibration in terms of the new operational radiological quantities Hp (10) and H(10) for different TLD systems (Harshaw TLD-100 and Panasonic UD-002) used in personal and environmental monitoring. The irradiations were performed in the Spanish Reference Laboratory in radiation protection levels, managed by the CIEMAT Metrology of ionizing radiations Unit. With those data, different calibrations of a panoramic gamma irradiator in terms of the radiological quantity for unit of time were established, providing the traceability of the irradiator to the Reference Laboratory using the corresponding TLD systems as transfer instruments. (Author) 9 refs

  12. Electron attenuation characteristics of LiF

    Energy Technology Data Exchange (ETDEWEB)

    Paliwal, B R [Wisconsin Univ., Madison (USA). Div. of Clinical Oncology; Almond, P R

    1976-08-01

    The results of a study, indicating the exponential nature of the attenuation of electrons in LiF, are reported. This conclusion holds good not only for the monoenergetic electrons obtained from several pure ..beta.. emitters but also for the high energy electron beams delivered by radiotherapy facilities.

  13. X-ray quality control using TLD-100

    International Nuclear Information System (INIS)

    Rojas S, D. A.; Garcia V, E.; Azorin N, J.; Gaona, E.

    2017-10-01

    The use of thermoluminescent dosimeters in the area of medical physics and especially in radiology is of great importance to guarantee the quality of a given study, for this reason the need to verify by means of measurements for quality control in X-rays using thermoluminescent dosimeters of LiF:Mg,Ti was raised. For this, measurements of air Kerma, beam efficiency (reproducibility and linearity) and determination of the hemi-reductive layer were carried out, where previously the dosimeters were used, the graphs of the linear equation were used to obtain the absorbed dose of each dosimeter and thus the results of the absorbed dose calculated analytically against the value estimated by an electronic dosimeter were compared; it was found that the values of the absorbed dose are quantities similar to those stipulated by the electronic dosimeter. These measurements made it possible to verify the quality of the equipment that was used in the comparison. (Author)

  14. Thermoluminescent response of LiF before variation of the heating rate; Respuesta termoluminiscente de LiF ante variacion de la tasa de calentamiento

    Energy Technology Data Exchange (ETDEWEB)

    Barrios, R. [Facultad de Quimica, UAEM, 50000 Toluca, Estado de Mexico (Mexico); Avila, O. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2003-07-01

    Comparisons of glow curves of lithium fluoride dosemeters TLD-100 measured to two heating rates with the purpose of quantifying the change in the temperature of the peaks 5 and 7 for the thermoluminescent reader equipment Harshaw 4000 of the thermoluminescence laboratory of the ININ were carried out. (Author)

  15. SFM study of ion-induced hillocks on LiF exposed to thermal and optical annealing

    International Nuclear Information System (INIS)

    Mueller, C.; Benyagoub, A.; Lang, M.; Neumann, R.; Schwartz, K.; Toulemonde, M.; Trautmann, C.

    2003-01-01

    Single crystals of LiF were irradiated at 10 different temperatures from room temperature to 780 K with Pb ions of 4.1 MeV/u. The irradiated surfaces were analyzed with scanning force microscopy, which revealed ion-induced hillocks with diameters of ∼20 nm and with heights of a few nm. Above 450 K, the number of hillocks strongly decreased with irradiation temperature. No hillocks were created under irradiation at 780 K. In addition, LiF samples irradiated at room temperature with Ni (2.5 MeV/u) and U ions (11.1 MeV/u) were bleached with UV-light on part of the crystal surface. In the bleached area, the characteristic F- and F 2 -centers disappeared, whereas the mean diameter and height of the hillocks did not show any significant change

  16. Colour centres induced in LiF by low-energy electrons

    CERN Document Server

    Baldacchini, G; Montereali, R M; Scacco, A

    1998-01-01

    A detailed study has been carried out on the optical properties of intrinsic colour centres, created in LiF crystals under irradiation with low-penetration 3 keV electrons. The kinetics of the production of F and M centres, determined from optical absorption measurements, exhibits a typical three-stage structure and an evident saturation at high doses. The quantitative evaluation of the kinetic parameters is in excellent agreement with the predictions of the most comprehensive theoretical model. A comparison of the effects of irradiation at different temperatures, determined from absorption and photoluminescence spectra, allows one to deduce the conditions for preferential formation of F sub 2 or F sub 3 sup + defects in LiF crystals. (author)

  17. Thermoluminescence responses of photon- and electron-irradiated lithium potassium borate co-doped with Cu+Mg or Ti+Mg

    International Nuclear Information System (INIS)

    Alajerami, Y.S.M.; Hashim, S.; Ramli, A.T.; Saleh, M.A.; Saripan, M.I.; Alzimami, K.; Min Ung, Ngie

    2013-01-01

    New glasses Li 2 CO 3 –K 2 CO 3 –H 3 BO 3 (LKB) co-doped with CuO and MgO, or with TiO 2 and MgO, were synthesized by the chemical quenching technique. The thermoluminescence (TL) responses of LKB:Cu,Mg and LKB:Ti,Mg irradiated with 6 MV photons or 6 MeV electrons were compared in the dose range 0.5–4.0 Gy. The standard commercial dosimeter LiF:Mg,Ti (TLD-100) was used to calibrate the TL reader and as a reference in comparison of the TL properties of the new materials. The dependence of the responses of the new materials on 60 Co dose is linear in the range of 1–1000 Gy. The TL yields of both of the co-doped glasses and TLD-100 are greater for electron irradiation than for photon irradiation. The TL sensitivity of LKB:Ti,Mg is 1.3 times higher than the sensitivity of LKB:Cu,Mg and 12 times less than the sensitivity of TLD-100. The new TL dosimetric materials have low effective atomic numbers, good linearity of the dose responses, excellent signal reproducibility, and a simple glow curve structure. This combination of properties makes them suitable for radiation dosimetry. - Highlights: • Enhancement of about three times has been shown with the increment of MgO. • A comparison was carried out between the TL responses of the prepared dosimeters and TLD-100. • The prepared dosimeters show simple glow curve, low Z material and excellent reproducibility. • The TL measurements show a linear dose response in a long span of exposures. • The electron response shows 1.18 times greater than photon response for the prepared dosimeters

  18. Photoluminescence of magnesium-associated color centers in LiF crystals implanted with magnesium ions

    Science.gov (United States)

    Nebogin, S. A.; Ivanov, N. A.; Bryukvina, L. I.; V. Shipitsin, N.; E. Rzhechitskii, A.; Papernyi, V. L.

    2018-05-01

    In the present paper, the effect of magnesium nanoparticles implanted in a LiF crystal on the optical properties of color centers is studied. The transmittance spectra and AFM images demonstrate effective formation of the color centers and magnesium nanoparticles in an implanted layer of ∼ 60-100 nm in thickness. Under thermal annealing, a periodical structure is formed on the surface of the crystal and in the implanted layer due to self-organization of the magnesium nanoparticles. Upon excitation by argon laser with a wavelength of 488 nm at 5 K, in a LiF crystal, implanted with magnesium ions as well as in heavily γ-irradiated LiF: Mg crystals, luminescence of the color centers at λmax = 640 nm with a zero-phonon line at 601.5 nm is observed. The interaction of magnesium nanoparticles and luminescing color centers in a layer implanted with magnesium ions has been revealed. It is shown that the luminescence intensity of the implanted layer at a wavelength of 640 nm is by more than two thousand times higher than that of a heavily γ-irradiated LiF: Mg crystal. The broadening of the zero-phonon line at 601.5 nm in the spectrum of the implanted layer indicates the interaction of the emitting quantum system with local field of the surface plasmons of magnesium nanoparticles. The focus of this work is to further optimize the processing parameters in a way to result in luminescence great enhancement of color centers by magnesium nanoparticles in LiF.

  19. Effect of spectral shape in the relative efficiency of LiF: Mg,Ti exposed to 20 keV effective energy X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Ixquiac-Cabrera, J.M., E-mail: mixquiac@nucleares.unam.m [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, A.P. 70-543, 04510 DF (Mexico); Departamento de Fisica, Universidad de San Carlos de Guatemala, Edificio T-1 Facultad de Ingenieria (Guatemala); Brandan, M.E.; Martinez-Davalos, A.; Rodriguez-Villafuerte, M.; Ruiz-Trejo, C. [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, A.P. 20-364, 01000 DF (Mexico); Gamboa-deBuen, I. [Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, A.P. 70-543, 04510 DF (Mexico)

    2011-04-15

    This work is aimed at studying the possible dependence of the thermoluminescent response of LiF:Mg,Ti (TLD-100) on the X-ray beam spectrum. TLD-100 chips were irradiated with 20 keV effective energy filtered tungsten X-ray spectra, generated by a tube operated at 30, 40, 50, 60, 70 and 80 kV, and the response was measured relative to the response to {sup 60}Co gammas. TLDs were exposed in air at air kerma values between 50 and 300 mGy. Glow curve deconvolution into 8 peaks (3, 4, 5, 6a, 6b, 7, 8 and 9) was performed in order to evaluate the response of individual peaks and regions of interest in the glow curve. Results show that all peaks display a linear response, at least up to 200 mGy, for all X-ray beam qualities. The relative response of the total glow curve area, the dosimetric region (peaks 3 + 4 + 5) and peaks 5 to 9 is statistically constant for beams generated by voltages from 30 to 70 kV; for 80 kV, the values are lower by about 20% for peaks 8 and 9 and 9% for the rest. The relative efficiency for the glow curve area, the dosimetric region and peaks 5 (1.15, 1.10 and 1.13), peaks 8 and 9 (2.05 and 1.55) do not depend on the beam spectrum between 30 and 70 kV, while for 80 kV the efficiency is lower. For peaks 6a, 6b and 7, relative efficiencies (1.91, 2.94 and 2.60) are voltage independent.

  20. Evaluation and comparison of absorbed dose for electron beams by LiF and diamond dosimeters

    International Nuclear Information System (INIS)

    Mosia, G.J.; Chamberlain, A.C.

    2007-01-01

    The absorbed dose response of LiF and diamond thermoluminescent dosimeters (TLDs), calibrated in 60 Co γ-rays, has been determined using the MCNP4B Monte Carlo code system in mono-energetic megavoltage electron beams from 5 to 20 MeV. Evaluation of the dose responses was done against the dose responses of published works by other investigators. Dose responses of both dosimeters were compared to establish if any relation exists between them. The dosimeters were irradiated in a water phantom with the centre of their top surfaces (0.32x0.32 cm 2 ), placed at d max perpendicular to the radiation beam on the central axis. For LiF TLD, dose responses ranged from 0.945±0.017 to 0.997±0.011. For the diamond TLD, the dose response ranged from 0.940±0.017 to 1.018±0.011. To correct for dose responses by both dosimeters, energy correction factors were generated from dose response results of both TLDs. For LiF TLD, these correction factors ranged from 1.003 up to 1.058 and for diamond TLD the factors ranged from 0.982 up to 1.064. The results show that diamond TLDs can be used in the place of the well-established LiF TLDs and that Monte Carlo code systems can be used in dose determinations for radiotherapy treatment planning

  1. Suppression of leukocyte inhibitory factor (LIF) production and [3H]thymidine incorporation by concanavalin A-activated mononuclear cells

    International Nuclear Information System (INIS)

    Lomnitzer, R.; Rabson, A.R.

    1979-01-01

    The capacity of human mononuclear (MN) cells pretreated with concanavalin A (Con A) to suppress the activity of fresh phytohemagglutinin (PHA)-pulsed mononuclear cells was assessed. Con A-pretreated MN cells suppressed leukocyte inhibitory factor (LIF) activity in supernatants of PHA-pulsed cell cultures and [ 3 H]thymidine incorporation by these cells. Suppression was obtained in both allogeneic and autologous systems with mitomycin-treated, irradiated, or untreated Con A-induced cells. Lymphocytes from two patients that, following treatment with Con A, did not suppress mitogen-induced proliferative response of normal cells also did not suppress LIF production

  2. Synthesis and characterization of LiF: Mg, Ti for ionizing radiations dosimetry

    International Nuclear Information System (INIS)

    Lozano R, I. B.

    2011-01-01

    Among the different thermoluminescence materials (Tl), the LiF:Mg, Ti is the most used for dosimetric purposes, because its equivalence to the human tissue, it has an effective atomic number of 8.14, the best known commercial dosemeter of this kind is the TLD-100. However, because this dosimeter is an imported product, is quite expensive for many research groups and hospitals. The purpose of this work is the optimization of its synthesis, as the dosimetric characterization, so it can replace the imported dosimeters. The synthesis of LiF:Mg, Ti is a careful process, since one of the reagents, the ion fluorine is highly corrosive. In this work the synthesis of the LiF:Mg, Ti was done by the molten substance method, was used LiF of analytical grade and the magnesium (Mg) and titanium (Ti) activators were incorporated in aqueous solution. For to optimize the handle of the material Tl, we elaborated pellets and teflon (Ptfe) was used as agglutinate material, in a 2:3 proportion. First was prepared the LiF, incorporating just Mg as dopant with a concentration of 400 parts per million (ppm). After the Ti with concentrations from 15 to 120 ppm was incorporated keeping fixed the concentration of Mg (400 ppm). The morphological and structural characterization of the Tl material were made by scanning electron microscopy and X-ray diffraction. The optimal concentration of Ti, was determined as a function of the radiation dose sensibility of the Tl material. The material prepared with 60 ppm of the Ti showed a higher sensibility. However, also the rest of the preparations had the requirements recommended by the international agencies to be used in ionizing radiations dosimetry. For the dosimetric characterization were used samples with 400 ppm of Mg, 400 ppm Mg and 30 ppm Ti, 400 ppm Mg and 60 ppm Ti. The LiF:Mg showed its dosimetric peak at 240 C, while the LiF:Mg, Ti (30 ppm and 60 ppm Ti) showed their dosimetric peak at 220 C and 222 C respectively. The study of the Tl

  3. Thermoluminescent response of LiF before variation of the heating rate

    International Nuclear Information System (INIS)

    Barrios, R.; Avila, O.

    2003-01-01

    Comparisons of glow curves of lithium fluoride dosemeters TLD-100 measured to two heating rates with the purpose of quantifying the change in the temperature of the peaks 5 and 7 for the thermoluminescent reader equipment Harshaw 4000 of the thermoluminescence laboratory of the ININ were carried out. (Author)

  4. Traceability of a panoramic gamma irradiator using different TLD systems as transfer Instruments; Trazabilidad de un irradiador panoramico mediante sistemas de dosimetria TL

    Energy Technology Data Exchange (ETDEWEB)

    Romero, A. M.; Saez, J. C

    1994-07-01

    This work shows the calibration in terms of the new operational radiological quantities Hp (10) and H(10) for different TLD systems (Harshaw TLD-100 and Panasonic UD-002) used in personal and environmental monitoring. The irradiations were performed in the Spanish Reference Laboratory in radiation protection levels, managed by the CIEMAT Metrology of ionizing radiations Unit. With those data, different calibrations of a panoramic gamma irradiator in terms of the radiological quantity for unit of time were established, providing the traceability of the irradiator to the Reference Laboratory using the corresponding TLD systems as transfer instruments. (Author) 9 refs.

  5. Traceability of a panoramic gamma irradiator using different TLD systems as transfer instruments; Trazabilidad de un irradiador panoramico mediante sistemas de dosimetria TL

    Energy Technology Data Exchange (ETDEWEB)

    Romero, A.M.; Saez, J.C.

    1994-08-01

    This work shows the calibration in terms of the new operational radiological quantities Hp(10) and H*(10) for different TLD systems (Harshaw TLD-100 and Panasonic UD-802) used in personal and environmental monitoring. The irradiations were performed in the Spanish Reference Laboratory in radiation protection levels, managed by the CIEMAT Metrology of ionizing radiations Unit. With these data, different calibrations of a panoramic gamma irradiator in terms of the radiological quantity for unit of time were established, providing the traceability of the irradiator to the Reference Laboratory using the corresponding TLD systems as transfer instruments. (Author) 9 refs.

  6. Confocal fluorescence microscopy investigation of visible emitting defects induced by electron beam lithography in LIF films

    International Nuclear Information System (INIS)

    Montereali, R. M.; Bigotta, S.; Pace, A.; Piccinini, M.; Burattini, E.; Grilli, A.; Raco, A.; Giammatteo, M.; L'Aquila Univ., L'Aquila; Picozzi, P.; Santucci, S.; L'Aquila Univ., L'Aquila

    2000-01-01

    Low energy electron irradiation of lithium fluoride (LiF), in the form of bulk crystals and films, gives rise to the stable formation of primary F defects and aggregated color centers in a thin layer located at the surface of the investigated material. For the first time a confocal light scanning microscope (CLSM) in fluorescence mode was used to reconstruct the depth distribution of efficiently emitting laser active color centers in a stripe-like region induced by 12 and 16 keV electrons on LiF films thermally evaporated on glass. The formation of the F3+ and F2 aggregated defects appears restricted to the electron penetration and proportional to their energy depth profile, as obtained from Monte Carlo simulations [it

  7. Personal Dosemeter of Thermal Neutron Using A Cr-39 Detector with Filter Natural LiF

    International Nuclear Information System (INIS)

    Sofyan, Hasnel; Thamrin, M.Thoyib

    1996-01-01

    The research of personal dosemeter for thermal neutron using Cr-39 detector with different thicknesses of natural LiF filter was carried out. The irradiation of Cr-39 detector with neutron source from reactor research TRIGA mark II of Rikkyo University Tokyo, Japan. Nuclear track was counted by automatic method with ASPECT ver.4.22 Series A4T124 software and manual method for correction. The result of research, the maximum of nuclear tracks was obtained at 8 mm of LiF filter was 10 mm with 11,630x10E-5 track/neutron for air radiation. And on phantom radiation, the thickness of filter was 10 mm with 11,630x10E-5 track/neutron. Its values were 3.6 and 7.5 bigger than the response of Cr-39 non filter in air and on phantom radiation, respectively

  8. Point defects induced in LiF by low energy electrons

    International Nuclear Information System (INIS)

    Baldacchini, Giuseppe; Montereali, Rosa Maria; Scacco, Augusto; Cremona, Marco; D'Auria, Giuliano.

    1997-09-01

    A systematic study of the coloring of LiF crystals and films irradiated by 3 keV electrons at various temperatures was carried out analysing their absorption and luminescence spectra. The three stage behaviour of the F coloring curve as a function of the irradiation dose was revealed and the saturation of the process was identified for the first time with this kind of radiation. The kinetics of the defect formation confirmed the expectations derived from the most comprehensive theoretical model developed to explain the coloring process. The irradiation temperature was found to have an influence on both the proportion of different defects created and on their stability and the overall coloring efficiency turned out to be higher when the irradiation was performed on films. Various explanations to these observations are put forward and discussed

  9. Point defects induced in LiF by low energy electrons

    Energy Technology Data Exchange (ETDEWEB)

    Baldacchini, Giuseppe; Montereali, Rosa Maria [ENEA, Centro Ricerche Frascati, Rome (Italy); Scacco, Augusto [Rome, Univ. (Italy). Dipt. di Fisica]|[INFM, Rome (Italy); Cremona, Marco; D`Auria, Giuliano

    1997-09-01

    A systematic study of the coloring of LiF crystals and films irradiated by 3 keV electrons at various temperatures was carried out analysing their absorption and luminescence spectra. The three stage behaviour of the F coloring curve as a function of the irradiation dose was revealed and the saturation of the process was identified for the first time with this kind of radiation. The kinetics of the defect formation confirmed the expectations derived from the most comprehensive theoretical model developed to explain the coloring process. The irradiation temperature was found to have an influence on both the proportion of different defects created and on their stability and the overall coloring efficiency turned out to be higher when the irradiation was performed on films. Various explanations to these observations are put forward and discussed.

  10. {sup 6}LiF oleic acid capped nanoparticles entrapment in siloxanes for thermal neutron detection

    Energy Technology Data Exchange (ETDEWEB)

    Carturan, S., E-mail: sara.carturan@lnl.infn.it; Maggioni, G., E-mail: Gianluigi.maggioni@lnl.infn.it [Department of Physics and Astronomy, University of Padova, Via Marzolo 8, 35100 Padova (Italy); INFN, Laboratori Nazionali di Legnaro, Viale dell’Università 2, 35020 Legnaro (Italy); Marchi, T.; Gramegna, F.; Cinausero, M. [INFN, Laboratori Nazionali di Legnaro, Viale dell’Università 2, 35020 Legnaro (Italy); Quaranta, A. [Department of Industrial Engineering, University of Trento, Trento (Italy); INFN, Tifpa, Trento (Italy); Palma, M. Dalla [INFN, Laboratori Nazionali di Legnaro, Viale dell’Università 2, 35020 Legnaro (Italy); Department of Industrial Engineering, University of Trento, Trento (Italy)

    2016-07-07

    The good light output of siloxane based scintillators as displayed under γ-rays and α particles has been exploited here to obtain clear and reliable response toward thermal neutrons. Sensitization towards thermal neutrons has been pursued by adding {sup 6}LiF, in form of nanoparticles. Aiming at the enhancement of compatibility between the inorganic nanoparticles and the low polarity, siloxane based surrounding medium, oleic acid-capped {sup 6}LiF nanoparticles have been synthesized by thermal decomposition of Li trifluoroacetate. Thin pellets siloxane scintillator maintained their optical transmittance up to weight load of 2% of {sup 6}Li. Thin samples with increasing {sup 6}Li concentration and thicker ones with fixed {sup 6}Li amount have been prepared and tested with several sources (α, γ-rays, moderated neutrons). Light output as high as 80% of EJ212 under α irradiation was measured with thin samples, and negligible changes have been observed as a result of {sup 6}LiF addition. In case of thick samples, severe light loss has been observed, as induced by opacity. Nevertheless, thermal neutrons detection has been assessed and the data have been compared with GS20, based on Li glass, taken as a reference material.

  11. Confocal fluorescence microscopy investigation of visible emitting defects induced by electron beam lithography in LIF films

    Energy Technology Data Exchange (ETDEWEB)

    Montereali, R.M.; Bigotta, S.; Pace, A.; Piccinini, M. [ENEA, Divisione Fisica Applicata, Centro Ricerche Frascati, Frascati, RM (Italy); Burattini, E.; Grilli, A.; Raco, A. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Fisica, Frascati, Rome (Italy); Giammatteo, M. [Unita' Istituto Nazionale di Fisica Nucleare, Frascati, RM (Italy)]|[L' Aquila Univ., L' Aquila (Italy). Centro di Microscopia Elettronica; Picozzi, P.; Santucci, S. [Unita' Istituto Nazionale di Fisica Nucleare, Frascati, RM (Italy)]|[L' Aquila Univ., L' Aquila (Italy). Dipt. di Fisica

    2000-07-01

    Low energy electron irradiation of lithium fluoride (LiF), in the form of bulk crystals and films, gives rise to the stable formation of primary F defects and aggregated color centers in a thin layer located at the surface of the investigated material. For the first time a confocal light scanning microscope (CLSM) in fluorescence mode was used to reconstruct the depth distribution of efficiently emitting laser active color centers in a stripe-like region induced by 12 and 16 keV electrons on LiF films thermally evaporated on glass. The formation of the F{sub 3}{sup +} and F{sub 2} aggregated defects appears restricted to the electron penetration and proportional to their energy depth profile, as obtained from Monte Carlo simulations. [Italian] L'irraggiamento con elettroni di bassa energia del fluoruro di litio (LiF), in forma di cristalli e film, induce la formazione di difetti primari F e centri di colore aggregati stabili in un sottile strato localizzato alla superficie del materiale investigato. Per la prima volta un microscopio confocale a scansione (CLSM) in modalita' fluorescenza e' stato usato per ricostruire la distribuzione di centri di colore laser attivi ad alta efficienza di emissione nel visibile, in strisce colorate ottenute con elettroni da 12 e 16 keV su film di LiF evaporati termicamente su vetro. La formazione dei difetti aggregati F2 e F3+ risulta ristretta spazialmente nella regione di penetrazione degli elettroni e proporzionale al profilo della distribuzione dell'energia da essi depositata, ricavata tramite simulazioni Monte Carlo.

  12. Luminescent emission of LiF: Mg, Ti exposed to UV radiation; Emision luminiscente del LiF: Mg, Ti expuesto a la radiacion UV

    Energy Technology Data Exchange (ETDEWEB)

    Estrada G, A. [Estudiante de Facultad de Ciencias, UNAM, Circuito Exterior, 04500 Mexico D.F. (Mexico); Castano M, V.M. [Centro de Fisica Aplicada y Tecnologia Avanzada, UNAM, Campus Juriquilla, Queretaro (Mexico); Cruz Z, E.; Garcia F, F. [Instituto de Ciencias Nucleares UNAM, A.P. 70-543 Mexico D.F. (Mexico)

    2002-07-01

    It was investigated the luminescent emission stimulated by heat (Tl) of LiF: Mg, Ti crystals which were exposed to UV radiation coming from a mercury lamp. Since this crystal depends on the thermal history, it has been used a thermal treatment consisting of a baking at 380 C during one hour for each reading and they were irradiated with UV. The brilliance curves between 5 and 840 minutes of exposure in the face of UV light were obtained. An important loss in the response, starting from 150 minutes of irradiation was observed. Also the relative intensity of the brilliance curve decay when the crystals being stored in darkness and room temperature conditions, which is according to the results in the literature about. (Author)

  13. Obtention of a thermoluminescent material for dosimetry of ionizing radiation

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.

    1990-01-01

    The thermoluminescent dosemeters are small crystals which suffer changes in their structure by the radiation effect, being displaced the electrons toward higher energy levels. On heating the previously irradiated crystals, the electrons come back to their base state emitting light photons. The light quantity emitted is proportional to the received radiation dose. The light quantity emitted is proportional to the received radiation dose. The lithium fluoride is one of the thermoluminescent materials considered as tissue equivalents by having a low effective atomic number (Z ef ). At present, the more used commercial product used of this type is the TLD-100*. In this work the obtained results in the preparation of the lithium fluoride thermoluminescent material are presented. This is activated with magnesium (Mg) and titanium (Ti), which we have labelled as: LiF: Mg, Ti. The results from the tests performed for verifying his thermoluminescent properties are presented too, as powder form as in pellets form. These tests were performed in simultaneous form with TLD-100 samples, which is considered as reference. The LiF: Mg, Ti thermoluminescent material manufactured in the ININ presents similar dosimetric characteristics to those ones of the TLD-100. Therefore being able to replace the imported dosemeters. * (TLD-100 is a commercial trademark registered by Harshaw/Filtrol (US) for LiF: Mg, Ti Tl dosemeters) (Author)

  14. Obtention of a thermoluminescent material for dosimetry of ionizing radiation; Obtencion de un material termoluminiscente para dosimetria de la radiacion ionizante

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez M, P R

    1990-07-01

    The thermoluminescent dosemeters are small crystals which suffer changes in their structure by the radiation effect, being displaced the electrons toward higher energy levels. On heating the previously irradiated crystals, the electrons come back to their base state emitting light photons. The light quantity emitted is proportional to the received radiation dose. The light quantity emitted is proportional to the received radiation dose. The lithium fluoride is one of the thermoluminescent materials considered as tissue equivalents by having a low effective atomic number (Z{sub ef}). At present, the more used commercial product used of this type is the TLD-100*. In this work the obtained results in the preparation of the lithium fluoride thermoluminescent material are presented. This is activated with magnesium (Mg) and titanium (Ti), which we have labelled as: LiF: Mg, Ti. The results from the tests performed for verifying his thermoluminescent properties are presented too, as powder form as in pellets form. These tests were performed in simultaneous form with TLD-100 samples, which is considered as reference. The LiF: Mg, Ti thermoluminescent material manufactured in the ININ presents similar dosimetric characteristics to those ones of the TLD-100. Therefore being able to replace the imported dosemeters. * (TLD-100 is a commercial trademark registered by Harshaw/Filtrol (US) for LiF: Mg, Ti Tl dosemeters) (Author)

  15. Synthesis and characterization of nano- and microcrystalline cubes of pure and Ag-doped LiF

    Science.gov (United States)

    Alharbi, Najlaa D.; Salah, Numan; Habib, Sami S.; Alarfaj, Esam

    2013-01-01

    Lithium fluoride (LiF) produced in single crystals and doped with proper activators is a highly sensitive phosphor used in several applications such as integrated optics, colour centre laser and radiation dosimetry. In this work, we have developed a new synthetic chemical co-precipitation route for the synthesis of well-crystallized micro- and nanocrystalline cubes of pure and silver (Ag)-doped LiF. The as-synthesized samples were characterized by x-ray diffraction (XRD), scanning electron microscopy, absorption spectrum, photoluminescence (PL) and Raman spectroscopy. Size of the produced cubes could be controlled in the range 10 µm-50 nm by varying the solvent : co-solvent ratio. Micro-sized cubes could be grown in the presence of water as a solvent, while ethanol, which acts as a co-solvent, is found to be effective in reducing the size to the nanoscale. XRD results show complete crystalline structures in a griceite phase. The PL result of pure nanocubes exhibits a broad band in the range 370-550 nm, while that doped with Ag shows a prominent band at 420 nm. Raman spectra of the pure and Ag-doped LiF samples display several bands located in the range 80-236 cm-1. These results show that pure nanocubes of LiF have active colour centres without irradiation, which could be enhanced/modified by Ag dopants. This implies that these nanocubes might be useful in the development of optical devices.

  16. Synthesis and characterization of nano- and microcrystalline cubes of pure and Ag-doped LiF

    International Nuclear Information System (INIS)

    Alharbi, Najlaa D; Salah, Numan; Habib, Sami S; Alarfaj, Esam

    2013-01-01

    Lithium fluoride (LiF) produced in single crystals and doped with proper activators is a highly sensitive phosphor used in several applications such as integrated optics, colour centre laser and radiation dosimetry. In this work, we have developed a new synthetic chemical co-precipitation route for the synthesis of well-crystallized micro- and nanocrystalline cubes of pure and silver (Ag)-doped LiF. The as-synthesized samples were characterized by x-ray diffraction (XRD), scanning electron microscopy, absorption spectrum, photoluminescence (PL) and Raman spectroscopy. Size of the produced cubes could be controlled in the range 10 µm-50 nm by varying the solvent:co-solvent ratio. Micro-sized cubes could be grown in the presence of water as a solvent, while ethanol, which acts as a co-solvent, is found to be effective in reducing the size to the nanoscale. XRD results show complete crystalline structures in a griceite phase. The PL result of pure nanocubes exhibits a broad band in the range 370-550 nm, while that doped with Ag shows a prominent band at 420 nm. Raman spectra of the pure and Ag-doped LiF samples display several bands located in the range 80-236 cm -1 . These results show that pure nanocubes of LiF have active colour centres without irradiation, which could be enhanced/modified by Ag dopants. This implies that these nanocubes might be useful in the development of optical devices.

  17. LIF is a contraction-induced myokine stimulating human myocyte proliferation

    DEFF Research Database (Denmark)

    Broholm, Christa; Laye, Matthew J; Brandt, Claus

    2011-01-01

    in skeletal muscle, but LIF was not detectable in plasma of the subjects. However, electrically stimulated cultured human myotubes produced and secreted LIF, suggesting that LIF is a myokine with local effects. The well-established exercise-induced signaling molecules PI3K, Akt and mTor contributed...... to the regulation of LIF in cultured human myotubes as chemical inhibition of PI3K and mTor and siRNA knockdown of Akt1 were independently sufficient to down regulate LIF. Human myoblast proliferation was increased by recombinant exogenous LIF and decreased by siRNA knockdown of the endogenous LIF receptor. Finally...

  18. LIF supports primitive endoderm expansion during pre-implantation development

    DEFF Research Database (Denmark)

    Morgani, Sophie M; Brickman, Joshua M

    2015-01-01

    Embryonic stem cells (ESCs) are pluripotent cell lines that can be maintained indefinitely in an early developmental state. ESC culture conditions almost always require the cytokine LIF to maintain self-renewal. As ESCs are not homogeneous but contain multiple populations reminiscent...... of the blastocyst, identifying the target cells of LIF is necessary to understand the propagation of pluripotency. We recently found that LIF acts under self-renewing conditions to stimulate the fraction of ESCs that express extraembryonic markers, but has little impact on pluripotent gene expression. Here, we...... derivatives, whereas the increase in PrE is mediated both by an increase in proliferation and inhibition of PrE apoptosis that is normally triggered in embryos with an excess of GATA6(+) cells. Thus, it appears that the relative size of the PrE is determined by the number of LIF-producing cells in the embryo...

  19. Thermoluminescence response of Ge-, Al- and Nd- doped optical fibers by 6 MeV - electron and 6 MeV - photon irradiations

    International Nuclear Information System (INIS)

    Hossain, I.; Moburak, A. A.; Saeed, M.A.; Wagiran, H.; Hida, N.; Yaakob, H.N.

    2015-01-01

    In this paper, we report the prediction of thermoluminescence responses of Neodymium-doped SiO 2 optical fibre with various dose ranges from 0.5 Gy to 4.0 Gy by 6 MeV - electron irradiations without requirement for experimental measurements. A technique has been developed to calculate prediction of 6 MeV - electron response of Neodymium-doped SiO 2 optical fibre by observing the measured TL response of 6 MV - photon and the ratio of known measured photon/electron yield ratio distribution for Ge-doped, Al-doped optical fibre and standard TLD 100 dosimeter. The samples were kept in gelatin capsule an irradiated with 6 MV - photon at the dose range from 0.5 Gy to 4.0 Gy. Siemens model Primus 3368 linear accelerator located at Hospital Sultan Ismail, Johor Bahru has been used to deliver the photon beam to the samples. We found the average response ratio of 6 MV - photon and 6 MeV - electron in Ge-doped, Al-doped optical fibre and standard TLD-100 dosimeter are 0.83(3). Observing the measured value of 6 MV - photon irradiation this average ratio is useful to find the prediction of thermoluminescence responses by 6 MeV - electron irradiation of Neodymium-doped SiO 2 optical fibre by the requirement for experimental measurements with various dose ranges from 0.5 Gy to 4.0 Gy by 6 MV - photon irradiations.

  20. Luminescent emission of LiF: Mg, Ti exposed to UV radiation

    International Nuclear Information System (INIS)

    Estrada G, A.; Castano M, V.M.; Cruz Z, E.; Garcia F, F.

    2002-01-01

    It was investigated the luminescent emission stimulated by heat (Tl) of LiF: Mg, Ti crystals which were exposed to UV radiation coming from a mercury lamp. Since this crystal depends on the thermal history, it has been used a thermal treatment consisting of a baking at 380 C during one hour for each reading and they were irradiated with UV. The brilliance curves between 5 and 840 minutes of exposure in the face of UV light were obtained. An important loss in the response, starting from 150 minutes of irradiation was observed. Also the relative intensity of the brilliance curve decay when the crystals being stored in darkness and room temperature conditions, which is according to the results in the literature about. (Author)

  1. Energy measurements of thermally stimulated exoelectrons from LiF single crystals

    International Nuclear Information System (INIS)

    Kubozoe, T.; Watanabe, Y.

    1986-01-01

    In the course of energy measurements of thermally stimulated exoelectrons from LiF single crystal irradiated with X rays, the integral energy spectrum is found to be broad and to deviate from an exponential distribution, and the onset of saturation current is not around zero volts. However, with an increasing period of illumination with UV radiation just after X-ray irradiation, the onset of saturation current goes toward zero volts and the energy spectrum can be approximated by an exponential distribution. The mean energy is then evaluated to be approximately 0.3 eV. Experimental spectra are compared with those of Monte Carlo calculations based on a model with an overthermal exponential distribution, taking into account electron-phonon interactions and satisfactory agreement is obtained. (author)

  2. LIF Mediates Proinvasive Activation of Stromal Fibroblasts in Cancer

    Directory of Open Access Journals (Sweden)

    Jean Albrengues

    2014-06-01

    Full Text Available Signaling crosstalk between tumor cells and fibroblasts confers proinvasive properties to the tumor microenvironment. Here, we identify leukemia inhibitory factor (LIF as a tumor promoter that mediates proinvasive activation of stromal fibroblasts independent of alpha-smooth muscle actin (α-SMA expression. We demonstrate that a pulse of transforming growth factor β (TGF-β establishes stable proinvasive fibroblast activation by inducing LIF production in both fibroblasts and tumor cells. In fibroblasts, LIF mediates TGF-β-dependent actomyosin contractility and extracellular matrix remodeling, which results in collective carcinoma cell invasion in vitro and in vivo. Accordingly, carcinomas from multiple origins and melanomas display strong LIF upregulation, which correlates with dense collagen fiber organization, cancer cell collective invasion, and poor clinical outcome. Blockade of JAK activity by Ruxolitinib (JAK inhibitor counteracts fibroblast-dependent carcinoma cell invasion in vitro and in vivo. These findings establish LIF as a proinvasive fibroblast producer independent of α-SMA and may open novel therapeutic perspectives for patients with aggressive primary tumors.

  3. Proposal of a postal system for Ir-192 sources calibration used in high dose rate brachytherapy with LiF:Mn:Ti thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Vieira, W.S.; Borges, J.C.; Almeida, C.E.V.

    1998-01-01

    A proposal in order to improve the brachytherapy quality control and to allow postal intercomparison of Ir-192 sources used in high dose rate brachytherapy has been presented. The LiF: Mn: Ti (TLD 100) detector has been selected for such purpose. The experimental array and the TLDs irradiation and calibration techniques, at the treatment units, have been specified in the light of more recent methodology of Ir-192 calibration sources. (Author)

  4. LIF-dependent signaling: new pieces in the Lego.

    Science.gov (United States)

    Mathieu, Marie-Emmanuelle; Saucourt, Claire; Mournetas, Virginie; Gauthereau, Xavier; Thézé, Nadine; Praloran, Vincent; Thiébaud, Pierre; Bœuf, Hélène

    2012-03-01

    LIF, a member of the IL6 family of cytokine, displays pleiotropic effects on various cell types and organs. Its critical role in stem cell models (e.g.: murine ES, human mesenchymal cells) and its essential non redundant function during the implantation process of embryos, in eutherian mammals, put this cytokine at the core of many studies aiming to understand its mechanisms of action, which could benefit to medical applications. In addition, its conservation upon evolution raised the challenging question concerning the function of LIF in species in which there is no implantation. We present the recent knowledge about the established and potential functions of LIF in different stem cell models, (embryonic, hematopoietic, mesenchymal, muscle, neural stem cells and iPSC). We will also discuss EVO-DEVO aspects of this multifaceted cytokine.

  5. Contribution to the radio crystallographic study of the effect of neutrons on LiF monocrystals (1962); Contribution a l'etude radiocristallographique de l'effet des neutrons sur les monocristaux de LiF (1962)

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, M; Tournarie, M [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1962-07-01

    We have studied the changes in the 200 and 400 reflections in LiF monocrystals irradiated by neutrons, for doses of between 10{sup 17} and 10{sup 18} n/cm{sup 2}. The reflections are distinctly dissymmetric and in the case of doses under 5.10{sup 17} appear to consist of a fine peak associated with a wide and diffuse base. These appear to exist organised groups of point defects which lead to perturbed zones whose number varies very little with the irradiation and which exist perhaps beforehand. (authors) [French] Nous avons etudie l'evolution des reflexions 200 et 400 de monocristaux de LiF irradie aux neutrons pour des doses variant de 10{sup 17} a 10{sup 18} n/cm{sup 2}. Les reflexions presentent une nette dissymetrie et pour des doses inferieures a 5.10{sup 17} semblent constituees d'un pic fin associe a une base large et diffuse. Il semble qu'il y ait des rassemblements organises de defauts ponctuels pour donner des zones perturbees dans le nombre varierait peu avec l'irradiation et lui serait peut-etre preexistant. (auteurs)

  6. Analysis of the stability of the traps in LiF: Mg, Cu, P by deconvolution of it Tl curve; Analisis de la estabilidad de las trampas en LiF: Mg, Cu, P por deconvolucion de su curva TL

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, P.R. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Azorin, J. [UAM-I, San Rafael Atlixco 186, Col Vicentina 09340 Mexico, D.F. (Mexico); Furetta, C. [Universita degli Studi di Roma ' La Sapienza' , Piazzale Aldo Moro 2, 00185, Roma, (Italy); Lopez, J. [Facultad de Matematicas, UADY, s/C.P. Merida, Yucatan (Mexico)

    2004-07-01

    The results of the study of the stability of the traps are presented in Tl dosemeters of LiF: Mg,Cu,P + Ptfe, developed in the ININ, taking like reference to the commercial dosemeter GR200A of Chinese factory. The readings taken Tl the same day of the irradiation they presented four peaks whose energy, determined by deconvolution were; 1.30 {+-} 0.01 eV, 1.50 {+-} 0.01 eV, 1.70 {+-} 0.01 eV and 2.58{+-} 0.02 eV, for LiF: Mg,Cu,P + Ptfe, while for GR200A the energies were: 1.33 {+-} 0.11 eV, 1.58 {+-} 0.11 eV, 1.73 {+-} 0.11 eV and 2.60 {+-} 0.03 eV. The energy of the peaks 3 and 4 that remained visible during six months of study it was: 1.38 {+-} 0.01 eV and 2.65 {+-} 0.01 eV, for LiF: Mg,Cu,P + Ptfe respectively, in the same order for GR200A, the energies were: 1.51 {+-} 0.02 eV and 2.64 {+-} 0.03 eV. (Author)

  7. Response distributions of 6LiF and 7LiF thermoluminescence dosimeters in lithium blanket assemblies

    International Nuclear Information System (INIS)

    Maekawa, Hiroshi; Kusano, Jyo-ichi; Seki, Yasushi

    1976-11-01

    Measurement of the radiation-heating rate distribution in the fusion blanket is as important as measurement of the fission-rate distribution in a fission reactor. To obtain the information of radiation heating, the response (integral glow value) distributions in pseudo-spherical lithium assemblies with and without a graphite reflector were measured with 6 LiF and 7 LiF TLD's. The measured responses are normalized to values per source neutron. Experimental error is about 35%, and the error in positions of TLD's is about +- 3 mm. The experimental results are compared with those of calculation using RADHEAT code system and ENDF/B-III data file. (auth.)

  8. Analysis of the stability of the traps in LiF: Mg, Cu, P by deconvolution of it Tl curve

    International Nuclear Information System (INIS)

    Gonzalez, P.R.; Azorin, J.; Furetta, C.; Lopez, J.

    2004-01-01

    The results of the study of the stability of the traps are presented in Tl dosemeters of LiF: Mg,Cu,P + Ptfe, developed in the ININ, taking like reference to the commercial dosemeter GR200A of Chinese factory. The readings taken Tl the same day of the irradiation they presented four peaks whose energy, determined by deconvolution were; 1.30 ± 0.01 eV, 1.50 ± 0.01 eV, 1.70 ± 0.01 eV and 2.58± 0.02 eV, for LiF: Mg,Cu,P + Ptfe, while for GR200A the energies were: 1.33 ± 0.11 eV, 1.58 ± 0.11 eV, 1.73 ± 0.11 eV and 2.60 ± 0.03 eV. The energy of the peaks 3 and 4 that remained visible during six months of study it was: 1.38 ± 0.01 eV and 2.65 ± 0.01 eV, for LiF: Mg,Cu,P + Ptfe respectively, in the same order for GR200A, the energies were: 1.51 ± 0.02 eV and 2.64 ± 0.03 eV. (Author)

  9. Spiking Activity of a LIF Neuron in Distributed Delay Framework

    Directory of Open Access Journals (Sweden)

    Saket Kumar Choudhary

    2016-06-01

    Full Text Available Evolution of membrane potential and spiking activity for a single leaky integrate-and-fire (LIF neuron in distributed delay framework (DDF is investigated. DDF provides a mechanism to incorporate memory element in terms of delay (kernel function into a single neuron models. This investigation includes LIF neuron model with two different kinds of delay kernel functions, namely, gamma distributed delay kernel function and hypo-exponential distributed delay kernel function. Evolution of membrane potential for considered models is studied in terms of stationary state probability distribution (SPD. Stationary state probability distribution of membrane potential (SPDV for considered neuron models are found asymptotically similar which is Gaussian distributed. In order to investigate the effect of membrane potential delay, rate code scheme for neuronal information processing is applied. Firing rate and Fano-factor for considered neuron models are calculated and standard LIF model is used for comparative study. It is noticed that distributed delay increases the spiking activity of a neuron. Increase in spiking activity of neuron in DDF is larger for hypo-exponential distributed delay function than gamma distributed delay function. Moreover, in case of hypo-exponential delay function, a LIF neuron generates spikes with Fano-factor less than 1.

  10. Quantum chemical modelling of magnesium centers in LiF crystals

    International Nuclear Information System (INIS)

    Shlyuger, A.L.; Mysovskij, S.N.; Nepomnyashchikh, A.I.

    1989-01-01

    It is shown theoretically that optical absorption at 4.0 eV in LiF irradiated crystals is linked with Mg c + v a + v c - -centers (M-centers) and results from electron transitions from quasi-local staes in valent zone to vetre local state. V k and M-centres resulting from M-centre photodecolorization at low temperatures cause optical absorption with maxima at 3.5 and 5.0 eV. M-centres are transformed into M-centres oriented along axis at temperatures higher than 240 K. Optical excitation of M-centres oriented along axis with 5.5 eV maximum results in the initiation of luminescence at 2 eV

  11. CaF{sub 2}(Eu{sup 2+}):LiF - Structural and spectroscopic properties of a new system for neutron detection

    Energy Technology Data Exchange (ETDEWEB)

    Trojan-Piegza, Joanna, E-mail: jtp@eto.wchuwr.p [Department of Manufacturing Engineering, Boston University, 15 St. Mary' s Street, Boston, MA 02215 (United States); Faculty of Chemistry, Wroclaw University, 14 F. Joliot-Curie Street, Wroclaw 50-383 (Poland); Glodo, Jarek [RMD Inc., Watertown, MA (United States); Sarin, Vinod Kumar [Department of Manufacturing Engineering, Boston University, 15 St. Mary' s Street, Boston, MA 02215 (United States)

    2010-02-15

    A series of composites of CaF{sub 2}(Eu{sup 2+}) and LiF with different Ca/Li ratios were fabricated via liquid phase consolidation. Luminescent properties of these samples were investigated. Radioluminescence shows the typical Eu{sup 2+} blue emission in all the compositions. The energy spectra measured under gamma and neutron irradiation indicates that the most promising composition for neutron detection is the eutectic.

  12. Application of LiF for determining the gamma-radiation characteristics of the shut-down reactor

    Energy Technology Data Exchange (ETDEWEB)

    Ibragimova, E M; Musaeva, M A; Ashrapov, U T; Kalanov, M U; Muminov, M I [Inst. of Nuclear Physics, Tashkent (Uzbekistan)

    2005-07-01

    Full text: The power of {sup 60}Co {approx}1.25 MeV gamma-radiation source at the INP AS RUz is limited by 8 Gy/s, which does not satisfy several tasks of material science now. Therefore, we were first to suggest the irradiation of materials with gamma-rays of 0.1-7 MeV, which are emitted by the uranium fission products ({sup 41}Ar, {sup 135}Xe, {sup 125}Xe, {sup 125}I,{sup 137}Cs, {sup 134}Cs, {sup 144}Ce, {sup 95}Zr, {sup 140}Ba, {sup 140}La, {sup 99}Mo, {sup 60}Co) and {sup l6}N, {sup 24}Na, {sup 28}Al radio-nuclides in water during prophylactic shut-downs of our nuclear reactor WWR-SM. The gamma-dose rate kinetics was monitored with the ion current in ionization chambers KNK-53M fixed outside the reactor core from the stop-moment. The current kinetics comprised 4 steps with a high reproducibility at 2 and 0.5 {mu}A, then 50 and 10 nA, each lasting for 1,10, 40 and up to 200 hours, according to the isotope life-times. LiF crystal is known as a thermal luminescence dosimeter of mixed radiations up to 100 Gy. Yet in this work the absorbed gamma-energy dose D{sub {gamma}} was determined by accumulation of the known stable structure defects in thin cleaved LiF crystals: by induced optical absorption and luminescence of F- and M-centers. The samples were irradiated in Al-containers filled with water to keep the temperature of {approx}40 deg. C in the time range from 30 minutes to 150 hours. Optical absorption spectra were registered at spectrometer Specord M-40. Then the induced color center concentration was calculated by the Smakula relation, which is proportional to the absorbed dose D{gamma}. For a better reliability the photoluminescence center content was also determined. Selecting comparable close intensities of the induced absorption and luminescence bands obtained after irradiations of LiF references in the certified {sup 60}Co gamma-sources of the known gamma fluxes 0.7 and 7.5 Gy/s, the gamma-radiation intensity of the shut-down reactor was estimated in

  13. Application of LiF for determining the gamma-radiation characteristics of the shut-down reactor

    International Nuclear Information System (INIS)

    Ibragimova, E.M.; Musaeva, M.A.; Ashrapov, U.T.; Kalanov, M.U.; Muminov, M.I.

    2005-01-01

    Full text: The power of 60 Co ∼1.25 MeV gamma-radiation source at the INP AS RUz is limited by 8 Gy/s, which does not satisfy several tasks of material science now. Therefore, we were first to suggest the irradiation of materials with gamma-rays of 0.1-7 MeV, which are emitted by the uranium fission products ( 41 Ar, 135 Xe, 125 Xe, 125 I, 137 Cs, 134 Cs, 144 Ce, 95 Zr, 140 Ba, 140 La, 99 Mo, 60 Co) and l6 N, 24 Na, 28 Al radio-nuclides in water during prophylactic shut-downs of our nuclear reactor WWR-SM. The gamma-dose rate kinetics was monitored with the ion current in ionization chambers KNK-53M fixed outside the reactor core from the stop-moment. The current kinetics comprised 4 steps with a high reproducibility at 2 and 0.5 μA, then 50 and 10 nA, each lasting for 1,10, 40 and up to 200 hours, according to the isotope life-times. LiF crystal is known as a thermal luminescence dosimeter of mixed radiations up to 100 Gy. Yet in this work the absorbed gamma-energy dose D γ was determined by accumulation of the known stable structure defects in thin cleaved LiF crystals: by induced optical absorption and luminescence of F- and M-centers. The samples were irradiated in Al-containers filled with water to keep the temperature of ∼40 deg. C in the time range from 30 minutes to 150 hours. Optical absorption spectra were registered at spectrometer Specord M-40. Then the induced color center concentration was calculated by the Smakula relation, which is proportional to the absorbed dose Dγ. For a better reliability the photoluminescence center content was also determined. Selecting comparable close intensities of the induced absorption and luminescence bands obtained after irradiations of LiF references in the certified 60 Co gamma-sources of the known gamma fluxes 0.7 and 7.5 Gy/s, the gamma-radiation intensity of the shut-down reactor was estimated in correlation with the ion current as 10 nA = 15 Gy/s. At short times of irradiation the linear dose dependence

  14. Low temperature deformation mechanisms in LiF single crystals

    International Nuclear Information System (INIS)

    Fotedar, H.L.; Stroebe, T.G.

    1976-01-01

    An analysis of the deformation behavior of high purity LiF single crystals is given using yielding and work hardening data and thermally activated deformation parameters obtained in the temperature range 77-423 0 K. It is found that while the Fleischer mechanism is apparently valid experimentally over the thermally activated temperature range, vacancies produced in large numbers at 77 0 K could also play a role in determining the critical resolved shear stress at that temperature

  15. Selective creation of colour centres and peaks of thermally stimulated luminescence by VUV photons in LiF single crystals

    International Nuclear Information System (INIS)

    Vasil'chenko, E.; Kudryavtseva, I.; Lushchik, A.; Lushchik, Ch.; Nagirnyi, V.

    2005-01-01

    Processes of radiation creation and annealing of Frenkel defects as well as electron-hole processes have been studied in LiF single crystals with a various content of impurity ions by means of highly sensitive method of thermally stimulated luminescence (TSL) and other optical methods. In highly pure LiF crystals, X-irradiated at 4.2 K, the TSL peaks connected with the annealing of interstitial fluorine ions (25-40 K) or atoms, i.e. H centres (50-65 K) and self-trapped holes (120-140 K) have been separated. For the first time, the creation spectra of the TSL peaks at 480 and 550 K by 10-33 eV-photon irradiation at 295 K have been measured. The anomalously high creation efficiency of the TSL peak at 480 K by 11.7-12.3 eV and 26-27 eV photons is interpreted as the creation of near-impurity electronic excitations both, directly by photons and by hot conduction electrons. (copyright 2005 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  16. An investigation into the accuracy of Acuros(TM) BV in heterogeneous phantoms for a (192)Ir HDR source using LiF TLDs.

    Science.gov (United States)

    Manning, Siobhan; Nyathi, Thulani

    2014-09-01

    The aim of this study was to evaluate the accuracy of the new Acuros(TM) BV algorithm using well characterized LiF:Mg,Ti TLD 100 in heterogeneous phantoms. TLDs were calibrated using an (192)Ir source and the AAPM TG-43 calculated dose. The Tölli and Johansson Large Cavity principle and Modified Bragg Gray principle methods confirm the dose calculated by TG-43 at a distance of 5 cm from the source to within 4 %. These calibrated TLDs were used to measure the dose in heterogeneous phantoms containing air, stainless steel, bone and titanium. The TLD results were compared with the AAPM TG-43 calculated dose and the Acuros calculated dose. Previous studies by other authors have shown a change in TLD response with depth when irradiated with an (192)Ir source. This TLD depth dependence was assessed by performing measurements at different depths in a water phantom with an (192)Ir source. The variation in the TLD response with depth in a water phantom was not found to be statistically significant for the distances investigated. The TLDs agreed with Acuros(TM) BV within 1.4 % in the air phantom, 3.2 % in the stainless steel phantom, 3 % in the bone phantom and 5.1 % in the titanium phantom. The TLDs showed a larger discrepancy when compared to TG-43 with a maximum deviation of 9.3 % in the air phantom, -11.1 % in the stainless steel phantom, -14.6 % in the bone phantom and -24.6 % in the titanium phantom. The results have shown that Acuros accounts for the heterogeneities investigated with a maximum deviation of -5.1 %. The uncertainty associated with the TLDs calibrated in the PMMA phantom is ±8.2 % (2SD).

  17. Calibration of thermoluminescent dosimeters (LiF : Mg : Ti) at different x-ray energies

    International Nuclear Information System (INIS)

    Osman, Aziza Mobark

    1998-04-01

    In this work the distance between the x-ray target (source) and the reference point on the housing of the newly installed secondary standard dosimetry laboratory (SSDL) at Sudan Atomic Energy Commission in Soba were determined, using the inverse square law. Six x-ray qualities were used at different positions. The results showed that the distance of the source to reference point is found to be (22± 2 cm). The calibration factors for the (LIF: Mg: Ti) TLD chips with the harshow model 2000C reader was determined for x-ray energies for quality (3) (KV = 80, filtration (1mm Al +5.30 mm Cu, HVL= 0.59 mm Cu), and for quality (4) (KV = 100, filtration ( 1mm Al + 5.30 mm Cu), HVL= 1.15 mm Cu) at 3 meter distance. The calibration factors for these two qualities is found to be ( 0.1030 ± 0.0002 ), (o.1098± 0.0004 ) m Gray per nano coulomb respectively. These values m and those obtained earlier at SAEC (1996) lab, by using Sr-90 irradiator (Beta- energy 2.27 MeV) calibration factor is found to be ( 0.1030 mGray per nano coulomb), confirm that within accuracies needed at radiation protection level, ( LiF: Mg: TI ) TLDs chips can be considered as an energy independent detector in the studied energy range. It is suggested that further measurements should be carried for other energies for determination of calibration factors for the full range of energies in use. ( Author )

  18. Multiple Sclerosis and the LIF/IL-6 Axis: Use of Nanotechnology to Harness the Tolerogenic and Reparative Properties of LIF

    Directory of Open Access Journals (Sweden)

    Su M. Metcalfe

    2015-05-01

    Full Text Available Leukaemia inhibitory factor (LIF plays a critical role in “stemness” versus “differentiation”, a property that underpins the core value of LIF as a therapeutic for both the treatment of autoimmune disease and for promoting tissue repair. This value can be realized using nano-engineering technology, where a new generation of tools can, with unprecedented ability, manipulate biological functions. One striking example is the treatment of multiple sclerosis (MS. The underpinning biology is the newly identified LIF/IL-6 axis in T lymphocytes, which can tilt the behaviour between immune tolerance versus immune attack. This LIF/IL-6 axis is ideally suited to nanotherapeutic manipulation, given its inherent mechanistic simplicity of two mutually opposing feed-forward loops that determine either tolerogenic (LIF or inflammatory (IL-6 immunity. Using LIF that is formulated in biodegradable nanoparticles (LIF-NP and targeted to CD4+ T cells, the axis is harnessed towards immune tolerance. This has implications for the treatment of autoimmune diseases, where the clinical burden is immense. It encompasses more than 100 diseases and, in the USA alone, costs more than $100 billion in direct health care costs annually. Other properties of LIF include the promotion of healthy neuro-glial interactions within the central nervous system (CNS, where, in addition to MS, LIF-NP therapy is relevant to inflammatory neurodegenerative diseases that represent a large and increasing need within aging populations. Thirdly, LIF is a reparative growth factor that can maintain genomic plasticity. LIF-NP supports the use of stem cell-based therapies in regenerative medicine plus augment therapeutic benefits within the patient. These core properties of LIF are greatly amplified in value by the advantage of being formulated as nanoparticles, namely (i targeted delivery, (ii exploitation of endogenous regulatory pathways and (iii creation of surrogate micro-stromal niches

  19. Thermally and optically stimulated luminescence of AlN-Y2O3 ceramics after ionising irradiation

    DEFF Research Database (Denmark)

    Trinkler, L.; Bos, A.J.J.; Winkelman, A.J.M.

    1999-01-01

    , an essential drawback of AlN-Y2O3 is its high fading rate. Special attention has been focused on understanding and improving the fading properties. In particular, the influence of the ceramics production conditions and the additive concentration on the fading rate have been studied. Experimental results......Thermally (TL) and optically stimulated luminescence (OSL) were studied in AlN-Y2O3 ceramics after irradiation with ionising radiation. The extremely high TL sensitivity (approximately 60 times the sensitivity of LiF:Mg,Tl (TLD-100)) makes AlN-Y2O3 ceramics attractive as a TLD material. However...... on spectral properties and thermal evolution of OSL are also presented. The stimulation spectrum covers the spectral range from green to infrared light. A combination of thermal and optical stimulation allowed a correlation to be found between parameters of OSL and TL after the same irradiation dose...

  20. Localized transitions in the thermoluminescence of LiF : Mg,Ti: potential for nanoscale dosimetry

    CERN Document Server

    Horowitz, Y S; Biderman, S; Einav, Y

    2003-01-01

    We describe the effect of nanoscale spatially coupled trapping centre (TC)-luminescent centre (LC) pairs on the thermoluminescence (TL) properties of LiF : Mg,Ti. It is shown that glow peak 5a (a low-temperature satellite of the major glow peak 5) arises from localized electron-hole (e-h) recombination in a TC-LC pair believed to be based on Mg sup 2 sup + -Li sub v sub a sub c trimers (the TCs) coupled to Ti(OH) sub n molecules (the LCs). Due to the localized nature of the e-h pair, two important properties are affected: (i) heavy charged particle (HCP) TL efficiency: the intensity of peak 5a relative to peak 5 following HCP high-ionization density irradiation is greater than that following low ionization density irradiation in a manner somewhat similar to the ionization density dependence of the yield of double-strand breaks (DSBs) induced in DNA. Our experimental measurements in a variety of HCP and fast neutron radiation fields have demonstrated that the ratio of glow peaks 5a/5 is nearly independent of p...

  1. Surface morphology and interdiffusion of LiF in Alq3-based organic light-emitting devices.

    Science.gov (United States)

    Lee, Young Joo; Li, Xiaolong; Kang, Da-Yeon; Park, Seong-Sik; Kim, Jinwoo; Choi, Jeong-Woo; Kim, Hyunjung

    2008-09-01

    Highly efficient organic light-emitting devices (OLEDs) have been realized by insertion of a thin insulating lithium fluoride (LiF) layer between aluminum (Al) cathode and an electron transport layer, tris-(8-hydroxyquinoline) aluminum (Alq(3)). In this paper, we study the surface morphology of LiF on Alq(3) by synchrotron X-ray scattering and atomic force microscopy (AFM) as a function of thickness of LiF. We also study the interdiffusion of LiF into Al cathode as well as into Alq(3) layer as a function of temperature. Initially, LiF molecules are distributed randomly as clusters on the Alq(3) layer and then gradually form a layer as increasing LiF thickness. The interdiffusion of LiF into Al occurs more actively than into Alq(3) in annealing process. LiF on Alq(3) induces the ordering of Al to (111) direction strongly with increasing LiF thickness.

  2. Optical and paramagnetic properties of Ti in LiF

    International Nuclear Information System (INIS)

    Krystek, M.

    1982-01-01

    Titanium replaces substitutionally Li + at its lattice site in LiF. The resulting deep impurity must be understood as TiF 6 -cluster. The symmetry of this cluster is octahedral in the case of the unoccupied impurity. If the impurity will be occupied by an electron, a trigonal distortion of the cluster results, whereby the orbital degeneracy of the ground state will be liftet. Since the occupied impurity is paramagnetic, the symmetry reduction could be proved by ENDOR measurements. Using a calculated term diagram of the impurity inside the crystal a model is offered to explain the photoluminescence and the thermoluminescence of LiF:Ti. (orig./HP) [de

  3. LIF characterization of ancient umber ceramics and frescos; Applicazione della tecnica LIF alle antiche ceramiche umbre e agli affreschi

    Energy Technology Data Exchange (ETDEWEB)

    Fantoni, R.; Palucci, A.; Ribezzo, S. [ENEA, Centro Ricerche Frascati, Rome (Italy). Dipt. Innovazione; Borgia, I. [Perugia Univ., Perugia (Italy)

    1999-07-01

    The report shows the result carried out by the LIF (layer induced fluorescence) system developed for pigment analysis at ENEA (National Agency for New Technology, Energy and the Environment) Frascati research centre (Rome) . The frescos and ceramics by Umbria region (Italy) are analysed. [Italian] Vengono riportati i risultati ottenuti dall'indagine della fluorescenza indotta da laser su antiche ceramiche umbre e su affreschi. La tecnica e' stata anche utilizzata per determinare la fluorescenza dei pigmenti contenuti in campioni di affresco.

  4. LIF: A new Kriging based learning function and its application to structural reliability analysis

    International Nuclear Information System (INIS)

    Sun, Zhili; Wang, Jian; Li, Rui; Tong, Cao

    2017-01-01

    The main task of structural reliability analysis is to estimate failure probability of a studied structure taking randomness of input variables into account. To consider structural behavior practically, numerical models become more and more complicated and time-consuming, which increases the difficulty of reliability analysis. Therefore, sequential strategies of design of experiment (DoE) are raised. In this research, a new learning function, named least improvement function (LIF), is proposed to update DoE of Kriging based reliability analysis method. LIF values how much the accuracy of estimated failure probability will be improved if adding a given point into DoE. It takes both statistical information provided by the Kriging model and the joint probability density function of input variables into account, which is the most important difference from the existing learning functions. Maximum point of LIF is approximately determined with Markov Chain Monte Carlo(MCMC) simulation. A new reliability analysis method is developed based on the Kriging model, in which LIF, MCMC and Monte Carlo(MC) simulation are employed. Three examples are analyzed. Results show that LIF and the new method proposed in this research are very efficient when dealing with nonlinear performance function, small probability, complicated limit state and engineering problems with high dimension. - Highlights: • Least improvement function (LIF) is proposed for structural reliability analysis. • LIF takes both Kriging based statistical information and joint PDF into account. • A reliability analysis method is constructed based on Kriging, MCS and LIF.

  5. The hnRNP-Q protein LIF2 participates in the plant immune response.

    Directory of Open Access Journals (Sweden)

    Clémentine Le Roux

    Full Text Available Eukaryotes have evolved complex defense pathways to combat invading pathogens. Here, we investigated the role of the Arabidopsis thaliana heterogeneous nuclear ribonucleoprotein (hnRNP-Q LIF2 in the plant innate immune response. We show that LIF2 loss-of-function in A. thaliana leads to changes in the basal expression of the salicylic acid (SA- and jasmonic acid (JA- dependent defense marker genes PR1 and PDF1.2, respectively. Whereas the expression of genes involved in SA and JA biosynthesis and signaling was also affected in the lif2-1 mutant, no change in SA and JA hormonal contents was detected. In addition, the composition of glucosinolates, a class of defense-related secondary metabolites, was altered in the lif2-1 mutant in the absence of pathogen challenge. The lif2-1 mutant exhibited reduced susceptibility to the hemi-biotrophic pathogen Pseudomonas syringae and the necrotrophic ascomycete Botrytis cinerea. Furthermore, the lif2-1 sid2-2 double mutant was less susceptible than the wild type to P. syringae infection, suggesting that the lif2 response to pathogens was independent of SA accumulation. Together, our data suggest that lif2-1 exhibits a basal primed defense state, resulting from complex deregulation of gene expression, which leads to increased resistance to pathogens with various infection strategies. Therefore, LIF2 may function as a suppressor of cell-autonomous immunity. Similar to its human homolog, NSAP1/SYNCRIP, a trans-acting factor involved in both cellular processes and the viral life cycle, LIF2 may regulate the conflicting aspects of development and defense programs, suggesting that a conserved evolutionary trade-off between growth and defense pathways exists in eukaryotes.

  6. Radiation processes in glass of Ba(PO/sub 3/)/sub 2/-MgF/sub 2/-LiF system. [Gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Bocharova, T.V.; Karapetyan, G.O.; Khalilev, V.D.

    1984-11-01

    Optical spectra of additional absorption of glasses of Ba(PO/sub 3/)/sub 2/-MgF/sub 2/-LiF system ..gamma..-irradiated up to 10/sup 6/ R dose are presented. It was established that introduction of up to 70 mol% of fluorides into phosphate glass doesn't result in occurrence of AAB (additional absorption band) in spectra, related to color centers similar to F-centers in MgF/sub 2/ and LiF crystals. It was shown that occurring color centers in phosphate matrix form nonelementary AAB in approximately 20,000 cm/sup -1/ spectrum region. The contribution to the total spectrum of additional absorption in visible region is made, besides (PO)/sub 4/-centers, by radiation color centers related with the presence of Mg/sup +2/ ions near PO/sub 4/ tetrahedrons. It was assumed that change of AAB position and intensity with ..gamma..sub(max) approximately 20,000 cm/sup -1/ in fluorophosphate glass with regularly changed composition reflects structural rebuilding of glass network taking place simultaneously with fluoride introduction. The obtained results support the conclusion, that MgF/sub 2/ takes part in formation of structural glass network whereas LiF acts as a component which breaks phosphate chains.

  7. Improved processes in therapy dosimetry with solid LiF thermoluminescent detectors

    International Nuclear Information System (INIS)

    Toivonen, M.

    1991-08-01

    The thesis presents criteria for thermoluminescence dosimetry systems suitable for precision measurements and, moreover, a detailed examination of the sources of systematic and random error. Instructions are given for annealing processes, calibration procedures, quality control, and operational rules, which are necessary in modem TLD. The performances of some principally different systems are compared. The old LiF-powder-based TLD system, with an overall uncertainty of measurement of about 1.6 percent for ten repeated readouts and for irradiations under calibration conditions with Co-60, is still the best but a comparable, although slightly lower, accuracy of about 1.7 percent can be reached more conveniently with solid LiF detectors. In measurements where absolute system calibration is not of interest (i.e., in depth-dose curve measurements, etc.), the advantages of the simple powder-based system are even more concrete. An integrated TLD process is presented for progressive utilization of automation in precision measurements. The sources of random error and unknown systematic error in current readout instruments are examined. Mechanical tolerances in critical parts of the readout instruments are thought to be the reason why the method of heating with hot gas has not been superior with respect to the precision of measurements, in spite of the excellent repeatability of the glow curve shape observed for successive readouts

  8. Electronic Stopping Power in LiF from First Principles

    International Nuclear Information System (INIS)

    Pruneda, J. M.; Sanchez-Portal, D.; Arnau, A.; Juaristi, J. I.; Artacho, Emilio

    2007-01-01

    Using time-dependent density-functional theory we calculate from first principles the rate of energy transfer from a moving proton or antiproton to the electrons of an insulating material, LiF. The behavior of the electronic stopping power versus projectile velocity displays an effective threshold velocity of ∼0.2 a.u. for the proton, consistent with recent experimental observations, and also for the antiproton. The calculated proton/antiproton stopping-power ratio is ∼2.4 at velocities slightly above the threshold (v∼0.4 a.u.), as compared to the experimental value of 2.1. The projectile energy loss mechanism is observed to be extremely local

  9. The CANDELLE experiment for characterization of neutron sensitivity of LiF TLDs

    Science.gov (United States)

    Guillou, M. Le; Billebaud, A.; Gruel, A.; Kessedjian, G.; Méplan, O.; Destouches, C.; Blaise, P.

    2018-01-01

    As part of the design studies conducted at CEA for future power and research nuclear reactors, the validation of neutron and photon calculation schemes related to nuclear heating prediction are strongly dependent on the implementation of nuclear heating measurements. Such measurements are usually performed in low-power reactors, whose core dimensions are accurately known and where irradiation conditions (power, flux and temperature) are entirely controlled. Due to the very low operating power of such reactors (of the order of 100 W), nuclear heating is assessed by using dosimetry techniques such as thermoluminescent dosimeters (TLDs). However, although they are highly sensitive to gamma radiation, such dosimeters are also, to a lesser extent, sensitive to neutrons. The neutron dose depends strongly on the TLD composition, typically contributing to 10-30% of the total measured dose in a mixed neutron/gamma field. The experimental determination of the neutron correction appears therefore to be crucial to a better interpretation of doses measured in reactor with reduced uncertainties. A promising approach based on the use of two types of LiF TLDs respectively enriched with lithium-6 and lithium-7, precalibrated both in photon and neutron fields, has been recently developed at INFN (Milan, Italy) for medical purposes. The CANDELLE experiment is dedicated to the implementation of a pure neutron field "calibration" of TLDs by using the GENEPI-2 neutron source of LPSC (Grenoble, France). Those irradiation conditions allowed providing an early assessment of the neutron components of doses measured in EOLE reactor at CEA Cadarache with 10% uncertainty at 1σ.

  10. Fractal and multifractal analysis of LiF thin film surface

    International Nuclear Information System (INIS)

    Yadav, R.P.; Dwivedi, S.; Mittal, A.K.; Kumar, M.; Pandey, A.C.

    2012-01-01

    Highlights: ► Fractal and multifractal analysis of surface morphologies of the LiF thin films. ► Complexity and roughness of the LiF thin films increases as thickness increases. ► LiF thin films are multifractal in nature. ► Strength of the multifractality increases with thickness of the film. - Abstract: Fractal and multifractal analysis is performed on the atomic force microscopy (AFM) images of the surface morphologies of the LiF thin films of thickness 10 nm, 20 nm, and 40 nm, respectively. Autocorrelation function, height–height correlation function, and two-dimensional multifractal detrended fluctuation analysis (MFDFA) are used for characterizing the surface. It is found that the interface width, average roughness, lateral correlation length, and fractal dimension of the LiF thin film increase with the thickness of the film, whereas the roughness exponent decreases with thickness. Thus, the complexity and roughness of the LiF thin films increases as thickness increases. It is also demonstrated that the LiF thin films are multifractal in nature. Strength of the multifractality increases with thickness of the film.

  11. Study of T L LiF: Mg,Ti (Model JR1152C) material for its use in the environmental monitoring

    International Nuclear Information System (INIS)

    Molina P, D.; Diaz B, E.; Prendes A, M.

    1999-01-01

    In order to evaluate the possibility to use the T L material of LiF: Mg,Ti (Model JR1152C) as environmental dosemeter it was realized its characterization of it according to the established criterion in the standard IEC-1066. The properties studied were: homogeneity of the lot, reproducibility, response linearity, detection threshold, auto irradiation, residual signal, response pride (fading) and angular dependence. The results prove the compliment of the IEC requirements and therefore the applicability of this dosemeter in the environmental monitoring. (Author)

  12. Studying the Attribution of LiF in OLED by the - Characteristics

    Directory of Open Access Journals (Sweden)

    Chun-lin Zhang

    2010-01-01

    Full Text Available The organic light-emitting device (OLED with simple structures of indium tin oxide (ITO/tris(8-quinolinolato aluminum (Alq3/LiF/Al and ITO/Alq3/Al was fabricated to analyze the contribution of LiF in OLED. We used the - characteristics to investigate the contribution of LiF in OLED and found that the capacitance of the above-mentioned structures was 12.5 nF and 77.5 nF, respectively. It is shown that the LiF layer affects the property of OLED resulting in the change of the capacitance of the device.

  13. Observation of interference between stark and electric quadrupole transitions in LIF from He atoms in plasmas

    International Nuclear Information System (INIS)

    Takiyama, K.; Namba, S.; Furukawa, S.; Oda, T.; James, B.W.; Andruczyk, D.

    2004-01-01

    Interference between Stark-induced dipole and electric quadrupole amplitudes was observed in a He hollow cathode plasma with axial magnetic field perpendicular to the sheath electric field E by laser-induced fluorescence (LIF) method. Circularly polarized LIF signals were observed in the sheath region. Spatial profile of the degree of polarization P c showed characteristic features of the interference. Using theoretically calculated P c -E relationship, E-profile was successfully obtained form the measure P c . (author)

  14. LIF-activated Jak signaling determines Esrrb expression during late-stage reprogramming

    Directory of Open Access Journals (Sweden)

    Delun Huang

    2018-01-01

    Full Text Available The regulatory process of naïve-state induced pluripotent stem cell (iPSC generation is not well understood. Leukemia inhibitory factor (LIF-activated Janus kinase/signal transducer and activator of transcription 3 (Jak/Stat3 is the master regulator for naïve-state pluripotency achievement and maintenance. The estrogen-related receptor beta (Esrrb serves as a naïve-state marker gene regulating self-renewal of embryonic stem cells (ESCs. However, the interconnection between Esrrb and LIF signaling for pluripotency establishment in reprogramming is unclear. We screened the marker genes critical for complete reprogramming during mouse iPSC generation, and identified genes including Esrrb that are responsive to LIF/Jak pathway signaling. Overexpression of Esrrb resumes the reprogramming halted by inhibition of Jak activity in partially reprogrammed cells (pre-iPSCs, and leads to the generation of pluripotent iPSCs. We further show that neither overexpression of Nanog nor stimulation of Wnt signaling, two upstream regulators of Esrrb in ESCs, stimulates the expression of Esrrb in reprogramming when LIF or Jak activity is blocked. Our study demonstrates that Esrrb is a specific reprogramming factor regulated downstream of the LIF/Jak signaling pathway. These results shed new light on the regulatory role of LIF pathway on complete pluripotency establishment during iPSC generation.

  15. Neutron detection devices with 6LiF converter layers

    Science.gov (United States)

    Finocchiaro, Paolo; Cosentino, Luigi; Meo, Sergio Lo; Nolte, Ralf; Radeck, Desiree

    2018-01-01

    The demand for new thermal neutron detectors as an alternative to 3He tubes in research, industrial, safety and homeland security applications, is growing. These needs have triggered research and development activities about new generations of thermal neutron detectors, characterized by reasonable efficiency and gamma rejection comparable to 3He tubes. In this paper we show the state of art of a promising lowcost technique, based on commercial solid state silicon detectors coupled with thin neutron converter layers of 6LiF deposited onto carbon fiber substrates. Several configurations were studied with the GEANT4 simulation code, and then calibrated at the PTB Thermal Neutron Calibration Facility. The results show that the measured detection efficiency is well reproduced by the simulations, therefore validating the simulation tool in view of new designs. These neutron detectors have also been tested at neutron beam facilities like ISIS (Rutherford Appleton Laboratory, UK) and n_TOF (CERN) where a few samples are already in operation for beam flux and 2D profile measurements. Forthcoming applications are foreseen for the online monitoring of spent nuclear fuel casks in interim storage sites.

  16. A LIF-PIV investigation of turbulence induced by sprays

    Science.gov (United States)

    van der Voort, Dennis; Dam, Nico; van de Water, Willem; Clercx, Herman

    2017-11-01

    During the breakup of a high-speed liquid jet, it drags along and mixes the air surrounding it, creating turbulence. This turbulence can, in turn, influence the dispersion of the droplets in the resulting spray. Very little is known about the small-scale characteristics of the ambient turbulent flow. This work investigated spray-induced turbulence using (gas-phase) laser-induced fluorescent tracer particle image velocimetry (LIF-PIV), which suppresses the strong light scattering of jet and droplets on the images. The results for both a heptane (h) and water (w) spray (135 m/s and 125 m/s respectively) show that the heptane spray generates stronger turbulence due to the difference in breakup between the two fluids. Using a large-eddy estimation, carefully compensating for the finite size of the PIV windows, the dissipation rate ɛ and the small-scale turbulence characteristics are estimated as ɛh = 190 +/-25 m2s-3, ɛw = 120 +/-30 m2s-3, Reλ,h = 380 +/-40, Reλ,w = 290 +/-40, ηh = 65 +/-3 μm, and ηw = 75 +/-5 μm. We will discuss the influence of the turbulent fluctuations in the surrounding air on the dispersion of droplets. This work is part of the research programme of the Foundation for Fundamental Research on Matter (FOM), which is part of the Dutch Organisation for Scientific Research (NWO).

  17. Re-use of radio-thermoluminescent LiF without regeneration; Reemploi sans regeneration du LiF radiothermoluminescent

    Energy Technology Data Exchange (ETDEWEB)

    Portal, G; Francois, H; Blanchard, Ph [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1969-07-01

    There is at the present time a rapid development of dosimetry techniques using thermoluminescence. Amongst the many substance actually in use, research laboratories generally employ lithium fluoride which is of particular interest for dosing {beta} radiation and low-energy X and {gamma} radiation. It might also be of use in radioprotection if its practical application were simpler. It has in effect unstable traps situated just below the surface which adversely affect the measurements if the material is not regenerated before each operation; this process considerably complicates the carrying out of measurements in the field of radioprotection. We have prepared a lithium fluoride giving unstable peaks which are less pronounced that those of the commercially available product and which can therefore be used without regeneration. In this report we compare the thermoluminescence curves for these two products. An analysis is given of the reasons for which this radio-thermoluminescent product has a stable luminescence curve and can be used almost one hundred times without being regenerated. We show that this quality can be retained when the LiF is used as a filler for teflon for applications in detectors. (authors) [French] On assiste a un developpement rapide des techniques de dosimetrie par thermoluminescence. Parmi les nombreux materiaux actuellement utilises, les laboratoires de recherche font generalement porter leur preference sur le fluorure de lithium qui est particulierement interessant pour la dosimetrie des rayonnements {beta} et des rayonnements X et {gamma} de faible energie. Ses qualites seraient egalement appreciees en radioprotection si sa mise en oeuvre etait plus simple. Il presente en effet des pieges instables situes a une faible profondeur qui alterent les mesures si l'on ne procede pas, avant chaque utilisation, a la regeneration du materiau, operation qui alourdit considerablement les mesures pratiquees en radioprotection. Nous avons prepare un

  18. Study of T L LiF: Mg,Ti (Model JR1152C) material for its use in the environmental monitoring; Estudio del material TL LiF: Mg, Ti (JR1152C) para su empleo en el monitoreo ambiental

    Energy Technology Data Exchange (ETDEWEB)

    Molina P, D.; Diaz B, E.; Prendes A, M. [Centro de Proteccion e Higiene de las Radiaciones, CPHR, Apdo. postal 6195, Habana 6, CP 10600, Ciudad Habana (Cuba)

    1999-07-01

    In order to evaluate the possibility to use the T L material of LiF: Mg,Ti (Model JR1152C) as environmental dosemeter it was realized its characterization of it according to the established criterion in the standard IEC-1066. The properties studied were: homogeneity of the lot, reproducibility, response linearity, detection threshold, auto irradiation, residual signal, response pride (fading) and angular dependence. The results prove the compliment of the IEC requirements and therefore the applicability of this dosemeter in the environmental monitoring. (Author)

  19. Three-Dimensional Conformal Radiotherapy in Prostate Cancer Patients: Rise in Interleukin 6 (IL-6) but not IL-2, IL-4, IL-5, Tumor Necrosis Factor-{alpha}, MIP-1-{alpha}, and LIF Levels

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira Lopes, Carlos [Universidade do Vale do Paraiba, Centro de Oncologia Radioterapica do Vale do Paraiba, Universidade do Vale do Paraiba Instituto de Pesquisa e Desenvolvimento, Universidade do Vale do Paraiba, Sao Jose dos Campos, Sao Paulo (Brazil); Callera, Fernando, E-mail: fcallera@gmail.com [Centro de Hematologia Onco-hematologia e Transplantes de Medula Ossea do Vale do Paraiba, Sao Paulo (Brazil)

    2012-03-15

    Purpose: To investigate the effect of radiotherapy (RT) on serum levels of interleukin-2 (IL-2), IL-4, IL-5, IL-6, tumor necrosis factor alpha (TNF-{alpha}), macrophage inflammatory protein-1-alpha (MIP-1-{alpha}) and leukemia inhibitory factor (LIF) in patients with prostate cancer. Methods and Materials: Forty eight patients with prostate cancer received three-dimensional conformal blocking radiation therapy with a linear accelerator. IL-2, IL-4, IL-5, IL-6, TNF-{alpha}, MIP-1-{alpha}, and LIF levels were measured by the related immunoassay kit 1 day before the beginning of RT and during RT at days 15 and 30. Results: The mean IL-2 values were elevated before and during the RT in contrast with those of IL-4, IL-5, IL-6, TNF-{alpha}, MIP-1-{alpha}, and LIF, which were within the normal range under the same conditions. Regarding markers IL-2, IL-4, IL-5, TNF-{alpha}, MIP-1-{alpha}, and LIF, comparisons among the three groups (before treatment and 15 and 30 days during RT) did not show significant differences. Although values were within the normal range, there was a significant rise in IL-6 levels at day 15 of RT (p = 0.0049) and a decline at day 30 to levels that were similar to those observed before RT. Conclusions: IL-6 appeared to peak after 15 days of RT before returning to pre-RT levels. In contrast, IL-2, IL-4, IL-5, TNF-{alpha}, MIP-1-{alpha}, and LIF levels were not sensitive to irradiation. The increased levels of IL-6 following RT without the concurrent elevation of other cytokines involved in the acute phase reaction did not suggest a classical inflammatory response to radiation exposure. Further studies should be designed to elucidate the role of IL-6 levels in patients with prostate cancer treated with RT.

  20. LIF inhibits osteoblast differentiation at least in part by regulation of HAS2 and its product hyaluronan.

    Science.gov (United States)

    Falconi, Dominic; Aubin, Jane E

    2007-08-01

    LIF arrests osteogenesis in fetal rat calvaria cells in a differentiation stage-specific manner. Differential display identified HAS2 as a LIF-induced gene and its product, HA, modulated osteoblast differentiation similarly to LIF. Our data suggest that LIF arrests osteoblast differentiation by altering HA content of the extracellular matrix. Leukemia inhibitory factor (LIF) elicits both anabolic and catabolic effects on bone. We previously showed in the fetal rat calvaria (RC) cell system that LIF inhibits osteoblast differentiation at the late osteoprogenitor/early osteoblast stage. To uncover potential molecular mediators of this inhibitory activity, we used a positive-negative genome-wide differential display screen to identify LIF-induced changes in the developing osteoblast transcriptome. Although LIF signaling is active throughout the RC cell proliferation-differentiation sequence, only a relatively small number of genes, in several different functional clusters, are modulated by LIF specifically during the LIF-sensitive inhibitory time window. Based on their known and predicted functions, most of the LIF-regulated genes identified are plausible candidates to be involved in the LIF-induced arrest of osteoprogenitor differentiation. To test this hypothesis, we further analyzed the function of one of the genes identified, hyaluronan synthase 2 (HAS2), in the LIF-induced inhibition. Synthesis of hyaluronan (HA), the product of HAS enzymatic activity, was stimulated by LIF and mimicked the HAS2 expression profile, with highest expression in early/proliferative and late/maturing cultures and lowest levels in intermediate/late osteoprogenitor-early osteoblast cultures. Exogenously added high molecular weight HA, the product of HAS2, dose-dependently inhibited osteoblast differentiation, with pulse-treatment effective in the same differentiation stage-specific inhibitory window as seen with LIF. In addition, however, pulse treatment with HA in early cultures

  1. Exposure times and ratio of readings produced by irradiation of thermoluminescence dosemeters in PTB neutron standard fields between 0.1 MeV and 19 MeV

    International Nuclear Information System (INIS)

    Jahr, R.; Guldbakke, S.; Cosack, M.

    1979-06-01

    6 LiF and 7 LiF thermoluminescence dosimeters (TLD) irradiated in a standard field of monoenergetic neutrons (Esub(n) = 0.1 MeV to 19 MeV), respond as well to the photon as to the neutron component of this radiation field. The ratio of the two TLD readings as well as the duration of irradiation required to obtain a preset TLD reading are calculated as a function of the neutron energy. (orig.) [de

  2. Analyzing the LiF thin films deposited at different substrate temperatures using multifractal technique

    Energy Technology Data Exchange (ETDEWEB)

    Yadav, R.P. [Department of Physics, University of Allahabad, Allahabad, UP 211002 (India); Dwivedi, S., E-mail: suneetdwivedi@gmail.com [K Banerjee Centre of Atmospheric and Ocean Studies, University of Allahabad, Allahabad, UP 211002 (India); Mittal, A.K. [Department of Physics, University of Allahabad, Allahabad, UP 211002 (India); K Banerjee Centre of Atmospheric and Ocean Studies, University of Allahabad, Allahabad, UP 211002 (India); Kumar, Manvendra [Nanotechnology Application Centre, University of Allahabad, Allahabad, UP 211002 (India); Pandey, A.C. [K Banerjee Centre of Atmospheric and Ocean Studies, University of Allahabad, Allahabad, UP 211002 (India); Nanotechnology Application Centre, University of Allahabad, Allahabad, UP 211002 (India)

    2014-07-01

    The Atomic Force Microscopy technique is used to characterize the surface morphology of LiF thin films deposited at substrate temperatures 77 K, 300 K and 500 K, respectively. It is found that the surface roughness of thin film increases with substrate temperature. The multifractal nature of the LiF thin film at each substrate temperature is investigated using the backward two-dimensional multifractal detrended moving average analysis. The strength of multifractility and the non-uniformity of the height probabilities of the thin films increase as the substrate temperature increases. Both the width of the multifractal spectrum and the difference of fractal dimensions of the thin films increase sharply as the temperature reaches 500 K, indicating that the multifractility of the thin films becomes more pronounced at the higher substrate temperatures with greater cluster size. - Highlights: • Analyzing LiF thin films using multifractal detrended moving average technique • Surface roughness of LiF thin film increases with substrate temperature. • LiF thin films at each substrate temperature exhibit multifractality. • Multifractility becomes more pronounced at the higher substrate temperatures.

  3. Fabrication of magnetic tunnel junctions with a single-crystalline LiF tunnel barrier

    Science.gov (United States)

    Krishna Narayananellore, Sai; Doko, Naoki; Matsuo, Norihiro; Saito, Hidekazu; Yuasa, Shinji

    2018-04-01

    We fabricated Fe/LiF/Fe magnetic tunnel junctions (MTJs) by molecular beam epitaxy on a MgO(001) substrate, where LiF is an insulating tunnel barrier with the same crystal structure as MgO (rock-salt type). Crystallographical studies such as transmission electron microscopy and nanobeam electron diffraction observations revealed that the LiF tunnel barrier is single-crystalline and has a LiF(001)[100] ∥ bottom Fe(001)[110] crystal orientation, which is constructed in the same manner as MgO(001) on Fe(001). Also, the in-plane lattice mismatch between the LiF tunnel barrier and the Fe bottom electrode was estimated to be small (about 0.5%). Despite such advantages for the tunnel barrier of the MTJ, the observed tunnel magnetoresistance (MR) ratio was low (˜6% at 20 K) and showed a significant decrease with increasing temperature (˜1% at room temperature). The results imply that indirect tunneling and/or thermally excited carriers in the LiF tunnel barrier, in which the current basically is not spin-polarized, play a major role in electrical transport in the MTJ.

  4. AxiaLIF system: minimally invasive device for presacral lumbar interbody spinal fusion.

    Science.gov (United States)

    Rapp, Steven M; Miller, Larry E; Block, Jon E

    2011-01-01

    Lumbar fusion is commonly performed to alleviate chronic low back and leg pain secondary to disc degeneration, spondylolisthesis with or without concomitant lumbar spinal stenosis, or chronic lumbar instability. However, the risk of iatrogenic injury during traditional anterior, posterior, and transforaminal open fusion surgery is significant. The axial lumbar interbody fusion (AxiaLIF) system is a minimally invasive fusion device that accesses the lumbar (L4-S1) intervertebral disc spaces via a reproducible presacral approach that avoids critical neurovascular and musculoligamentous structures. Since the AxiaLIF system received marketing clearance from the US Food and Drug Administration in 2004, clinical studies of this device have reported high fusion rates without implant subsidence, significant improvements in pain and function, and low complication rates. This paper describes the design and approach of this lumbar fusion system, details the indications for use, and summarizes the clinical experience with the AxiaLIF system to date.

  5. Triton and alpha-particle contribution from LiF converter for neutron dosimeter

    CERN Document Server

    Camacho, M E; Balcazar, M

    1999-01-01

    A personnel neutron dosimeter prototype based on chemical and electrochemical etched CR-39 detector, combined with LiF converter, has been calibrated using an ICRP-like phantom, under a heavy-water moderated Californium source neutron spectra; A conversion factor of 1.052+-126 spots cm sup - sup 2 mSv sup - sup 1 was obtained. The sealing properties of the detector holder showed a ten-fold reduction in radon background when it was tested in a high radon atmosphere. A convenient mechanical shock resistance was achieved in LiF converters by sintering to 11 tons pressure LiF powder at 650 deg. C, during one hour.

  6. Effect of divalent impurities on some physical properties of LiF and NaF

    International Nuclear Information System (INIS)

    Laj, C.

    1969-05-01

    The ionic thermo-currents technique is applied to the study of impurity vacancy dipoles in LiF and NaF doped with several divalent cations. In LiF only one ITC band is observed whatever the impurity studied. In NaF on the contrary two ITC bands are present, one corresponding to the one observed in LiF, the other one, intense in the case of small impurities, at lower temperature. A parallel EPR study in the case of Mn 2+ doped samples shows that the band observed in LiF and the corresponding one in NaF are due to the relaxation of dipoles formed by the association of an impurity and a vacancy in the next nearest position. The knowledge of the properties of the dipoles allows to show that the room temperature ionic conductivity of LiF is conditioned by the equilibrium: M ++ □+ → M ++ + □+. It is also shown that the isolated cation vacancy originating from this dissociation is responsible for the enhancement of γ-ray coloration of LiF doped with divalent cation impurities. A paramagnetic center ascribed to the presence of Mn 0 isolated in the lattice is also studied. The value of the hyperfine interaction and its temperature dependence are in good agreement with both the theory and the other experimental results. Finally it is shown that the disappearance of dipoles by annealing is related to the formation of complexes involving OH - ions, probably of the M(OH) 2 type, with the two OH - ions occupying a single fluorine site. (author) [fr

  7. Study of energetic dependence of LiF TLDs for photons

    International Nuclear Information System (INIS)

    Cavalieri, Tassio A.; Antunes, Paula C.G.; Paiva, Fabio; Branco, Isabela S.; Sena, Michelle K.S.; Siqueira, Paulo T.D.; Yoriyaz, Helio

    2015-01-01

    The LiF TLDs are widely used for photon dosimetry. However, in the most case the energetic dependence of these TLDs are not taken into account. This work is a preliminary study of energetic photon dependence in LiF TLD (TLD 700, enriched with 7 Li). For this study it was utilized a methodology already used in others works that seek understand the dependence energetic of TLD. It was utilized three different X-ray spectrum and a 137 Cs source; Beyond the calculus utilized in previous works, it was built the calibration curve for each spectrum to see the difference in dosimetry that the energetic dependence could cause. (author)

  8. Synthesis and thermoluminescent characterization of LiF doped with Ag; Sintesis y caracterizacion termoluminiscente de LiF dopado con Ag

    Energy Technology Data Exchange (ETDEWEB)

    Encarnacion, E. K.; Reyes, J.; Guerrero, Z. [Universidad Autonoma de Santo Domingo, Facultad de Ciencias, Ciudad Universitaria, Santo Domingo (Dominican Republic); Sosa, M. A.; Vallejo, M. A.; Rivera P, E., E-mail: emma.kee@gmail.com [Universidad de Guanajuato, Campus Leon, Division de Ciencias e Ingenierias, Loma del Bosque 103, Col. Lomas del Campestre, 37150 Leon, Guanajuato (Mexico)

    2015-10-15

    Full text: In this paper the synthesis and characterization of lithium fluoride (LiF) crystals pure and activated with silver (Ag) is reported. The synthesis was carried out by the method of co-precipitation; three samples were obtained one of pure LiF and two were activated with 0.02 and 0.04% of Ag. All samples were subjected to X-ray emission and the results were analyzed. The synthesized samples were characterized by X-ray diffraction, thermoluminescence and X-ray fluorescence. The XRD results show complete crystal structures. The radiation dosimetry responses are discussed. These are the first results of a research conducted at the Universidad Autonoma de Santo Domingo in collaboration with the Universidad de Guanajuato. (Author)

  9. Tl response of LiF:Mg, Cu, P + PTFE to Am-Be neutrons

    International Nuclear Information System (INIS)

    Gonzalez M, P.R.

    2000-01-01

    In different laboratories of the world it is followed the research about development of new Tl materials, whose main characteristics should be their equivalence with the tissue and their high sensibility to any type of radiation. The study consists in to measure the Tl peak intensity which TLD-100 presents at being irradiated with neutrons and that appears over 250 Centigrade, for compare it with the Tl intensity of the LiF: Mg, Cu, P + PTFE dosemeters. However, not all dosemeters of the same group show the interesting peak, by this only can be the total Tl intensity of dosemeters studied. In the ININ dosemeters development laboratory, we have developed a Tl material of lithium fluoride activated with magnesium, copper and phosphorus (LiF: Mg, Cu, P) that in polycrystalline powder form is almost 35 times more sensitive than the TLD-100 commercial dosemeter of Harshaw/Filtrol, USA. With the use of polytetrafluorethylene (PTFE) and with the above described Tl material, it has been possible to obtain dosemeters in pellet form of LiF: Mg, Cu, P + PTFE. (Author)

  10. Control of flowering and cell fate by LIF2, an RNA binding partner of the polycomb complex component LHP1.

    Directory of Open Access Journals (Sweden)

    David Latrasse

    Full Text Available Polycomb Repressive Complexes (PRC modulate the epigenetic status of key cell fate and developmental regulators in eukaryotes. The chromo domain protein like heterochromatin protein1 (LHP1 is a subunit of a plant PRC1-like complex in Arabidopsis thaliana and recognizes histone H3 lysine 27 trimethylation, a silencing epigenetic mark deposited by the PRC2 complex. We have identified and studied an LHP1-Interacting Factor2 (LIF2. LIF2 protein has RNA recognition motifs and belongs to the large hnRNP protein family, which is involved in RNA processing. LIF2 interacts in vivo, in the cell nucleus, with the LHP1 chromo shadow domain. Expression of LIF2 was detected predominantly in vascular and meristematic tissues. Loss-of-function of LIF2 modifies flowering time, floral developmental homeostasis and gynoecium growth determination. lif2 ovaries have indeterminate growth and produce ectopic inflorescences with severely affected flowers showing proliferation of ectopic stigmatic papillae and ovules in short-day conditions. To look at how LIF2 acts relative to LHP1, we conducted transcriptome analyses in lif2 and lhp1 and identified a common set of deregulated genes, which showed significant enrichment in stress-response genes. By comparing expression of LHP1 targets in lif2, lhp1 and lif2 lhp1 mutants we showed that LIF2 can either antagonize or act with LHP1. Interestingly, repression of the FLC floral transcriptional regulator in lif2 mutant is accompanied by an increase in H3K27 trimethylation at the locus, without any change in LHP1 binding, suggesting that LHP1 is targeted independently from LIF2 and that LHP1 binding does not strictly correlate with gene expression. LIF2, involved in cell identity and cell fate decision, may modulate the activity of LHP1 at specific loci, during specific developmental windows or in response to environmental cues that control cell fate determination. These results highlight a novel link between plant RNA

  11. Lifetime Improvement of Organic Light Emitting Diodes using LiF Thin Film and UV Glue Encapsulation

    Science.gov (United States)

    Huang, Jian-Ji; Su, Yan-Kuin; Chang, Ming-Hua; Hsieh, Tsung-Eong; Huang, Bohr-Ran; Wang, Shun-Hsi; Chen, Wen-Ray; Tsai, Yu-Sheng; Hsieh, Huai-En; Liu, Mark O.; Juang, Fuh-Shyang

    2008-07-01

    This work demonstrates the use of lithium fluoride (LiF) as a passivation layer and a newly developed UV glue for encapsulation on the LiF passivation layer to enhance the stability of organic light-emitting devices (OLEDs). Devices with double protective layers showed a 25-fold increase in operational lifetime compared to those without any packaging layers. LiF has a low melting point and insulating characteristics and it can be adapted as both a protective layer and pre-encapsulation film. The newly developed UV glue has a fast curing time of only 6 s and can be directly spin-coated onto the surface of the LiF passivation layer. The LiF thin film plus spin-coated UV glue is a simple packaging method that reduces the fabrication costs of OLEDs.

  12. High performance imaging of relativistic soft X-ray harmonics by sub-micron resolution LiF film detectors

    Energy Technology Data Exchange (ETDEWEB)

    Pikuz, Tatiana; Faenov, Anatoly [Quantum Beam Science Directorate, Japan Atomic Energy Agency, Kizugawa, Kyoto 619-0215 (Japan); Joint Institute for High Temperatures, Russian Academy of Sciences, Moscow 125412 (Russian Federation); Pirozhkov, Alexander; Esirkepov, Timur; Koga, James; Nakamura, Tatsufumi; Bulanov, Sergei; Fukuda, Yuji; Hayashi, Yukio; Kotaki, Hideyuki; Kando, Masaki [Quantum Beam Science Directorate, Japan Atomic Energy Agency, Kizugawa, Kyoto 619-0215 (Japan); Astapov, Artem; Pikuz, Sergey Jr. [Joint Institute for High Temperatures, Russian Academy of Sciences, Moscow 125412 (Russian Federation); Klushin, Georgy [Joint Institute for High Temperatures, Russian Academy of Sciences, Moscow 125412 (Russian Federation); International Laser Center of M.V. Lomonosov Moscow State University, Moscow (Russian Federation); Nagorskiy, Nikolai; Magnitskiy, Sergei [International Laser Center of M.V. Lomonosov Moscow State University, Moscow (Russian Federation); Kato, Yoshiaki [The Graduate School for the Creation of New Photonics Industries, Hamamatsu, Shizuoka (Japan)

    2012-12-15

    The spectrum variation and the coherent properties of the high-order harmonics (HOH) generated by an oscillating electron spikes formed at the joint of the boundaries of a cavity and a bow wave, which are created by a relativistically self-focusing laser in underdense gas jet plasma, are investigated. This new mechanism for HOH generation efficiently produces emission from ultraviolet up to the XUV ''water window'' spectral range. To characterize such source in the wide spectral range a diffraction imaging technique is applied. High spatial resolution EUV and soft X-ray LiF film detector have been used for precise measurements of diffraction patterns. The measurements under observation angle of 8 to the axis of laser beam propagation have been performed. The diffraction patterns were observed on the detector clearly, when the square mesh was placed at the distance of 500 mm from the output of plasma and at the distance of 27.2 mm in front of the detector. It is shown that observed experimental patterns are well consistent with modeled ones for theoretical HOH spectrum, provided by particle-in-cell simulations of a relativistic-irradiance laser pulse interaction with underdense plasma (copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  13. LIF-measurements on a low prassure RF-driven InBr lamp

    NARCIS (Netherlands)

    Mulders, H.C.J.; Stoffels, W.W.

    2007-01-01

    A laser induced fluorescence (LIF) experiment has been carried out on a low pressure, capacitively coupled RF driven. Ar discharge with InBr as an additive. The intention is to find the density of the different states of InBr and the metastable states in particular. We measured the density profile

  14. Development of 2D laser-induced fluorescence (LIF) system in high-density helicon plasma

    International Nuclear Information System (INIS)

    Teshigahara, Naoto; Shinohara, Shunjiro; Kuwahara, Daisuke; Watanabe, Masaki; Yamagata, Yukihiko

    2014-01-01

    Lifetimes of most electric propulsion devices are limited owing to electrode erosion and contamination by plasmas. To overcome this problem, a Helicon Electrodeless Advanced Thruster (HEAT) was proposed by our research team. This scheme employs a high-density (∼10 13 cm -3 ) helicon plasma accelerated by the Lorentz force, which is produced by various acceleration methods. For feasibility of this method, a Laser-Induced Fluorescence (LIF) system was developed. The LIF is a powerful tool for plasma diagnostics because it is a non-invasive method that allows high spatial resolution. Using the LIF, it is possible to deduce velocity distribution functions of different particles (ions, atoms, and molecules). In this paper, we report the details of our novel 2D LIF system as well as some preliminary experimental results. Argon ion velocity distributions at different axial and radial locations were obtained using the novel 2D system. Ion velocity was greatest (∼ 2.8 km/s) at z = -24 cm among all the points measured along the z-axis. Velocity values were approximately 2.7 and 3.2 km/s for radial positions of r = 0 and 3 cm, respectively. Ion temperature values were approximately 0.56 and 0.61 eV at r = 0 and 3 cm, respectively. (author)

  15. AxiaLIF system: minimally invasive device for presacral lumbar interbody spinal fusion

    Directory of Open Access Journals (Sweden)

    Rapp SM

    2011-08-01

    Full Text Available Steven M Rapp1, Larry E Miller2,3, Jon E Block31Michigan Spine Institute, Waterford, MI, USA; 2Miller Scientific Consulting Inc, Biltmore Lake, NC, USA; 3Jon E. Block, Ph.D., Inc., San Francisco, CA, USAAbstract: Lumbar fusion is commonly performed to alleviate chronic low back and leg pain secondary to disc degeneration, spondylolisthesis with or without concomitant lumbar spinal stenosis, or chronic lumbar instability. However, the risk of iatrogenic injury during traditional anterior, posterior, and transforaminal open fusion surgery is significant. The axial lumbar interbody fusion (AxiaLIF system is a minimally invasive fusion device that accesses the lumbar (L4–S1 intervertebral disc spaces via a reproducible presacral approach that avoids critical neurovascular and musculoligamentous structures. Since the AxiaLIF system received marketing clearance from the US Food and Drug Administration in 2004, clinical studies of this device have reported high fusion rates without implant subsidence, significant improvements in pain and function, and low complication rates. This paper describes the design and approach of this lumbar fusion system, details the indications for use, and summarizes the clinical experience with the AxiaLIF system to date.Keywords: AxiaLIF, fusion, lumbar, minimally invasive, presacral

  16. On the formation of hollow atoms in front of an insulating LiF surface

    NARCIS (Netherlands)

    Limburg, J; Hoekstra, R; Morgenstern, R; Kurz, H; Vana, M; Aumayr, F; Winter, HP

    KLL Auger spectra of hydrogenic (Is) N, O and Ne ions impinging on an insulating LiF(100) single crystal are presented. Beam energy and incident angle have been varied such that the lowest possible velocity towards the target is achieved, at the same time varying the velocity parallel to the target

  17. LIF diagnostics of hydroxyl radical in atmospheric pressure He-H2O dielectric barrier discharges

    Czech Academy of Sciences Publication Activity Database

    Dilecce, G.; Ambrico, P. F.; Šimek, Milan; De Benedictis, S.

    2012-01-01

    Roč. 398, č. 4 (2012), s. 142-147 ISSN 0301-0104 Institutional research plan: CEZ:AV0Z20430508 Keywords : Spectroscopic Techniques * Plasma Diagnostics * LIF * OH * Dielectric Barrier Discharge Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.957, year: 2012

  18. Development of a Laser Induced Fluorescence (LIF) System with a Tunable Diode Laser

    International Nuclear Information System (INIS)

    Woo, Hyun Jong; Do, Jeong Jun; You, Hyun Jong; Choi, Geun Sik; Lee, Myoung Jae; Chung, Kyu Sun

    2005-01-01

    The Laser Induced Fluorescence (LIF) is known as one of the most powerful techniques for measurements of ion velocity distribution function (IVDF) and ion temperature by means of Doppler broadening and Doppler shift. The dye lasers are generally used for LIF system with 611.66 nm (in vac.) for Ar ion, the low power diode laser was also proposed by Severn et al with the wavelength of 664.55 nm and 668.61 nm (in vac.) for Ar ion. Although the diode laser has the disadvantages of low power and small tuning range, it can be used for LIF system at the low temperature plasmas. A tunable diode laser with 668.614 nm of center wavelength and 10 GHz mode hop free tuning region has been used for our LIF system and it can be measured the ion temperature is up to 1 eV. The ion temperature and velocity distribution function have been measured with LaB6 plasma source, which is about 0.23 eV with Ar gas and 2.2 mTorr working pressure

  19. Scattering of 20Ne atoms from the (001) face of LiF

    International Nuclear Information System (INIS)

    Semerad, E.; Hoerl, E.M.

    1983-01-01

    An apparatus for measurements of inelastic scattering processes of gas atoms from crystal surfaces is described. Scattering experiments with Neon atoms of thermal energy on the (001) LiF surface in the azimuth are discussed. Inelastic scattering shows large contributions of single phonon interactions as well as of modes originating from the bulk bands. (Author)

  20. Monte Carlo Studies of a Novel LiF Radiator for RICH Detectors

    OpenAIRE

    Efimov, A.; Artuso, M.; Gao, Min; Mountain, R.; Muheim, F.; Mukhin, Y.; Playfer, S.

    1995-01-01

    We show that a multifaceted LiF radiator produces more Cherenkov light and has better resolution per photon than a flat radiator slab when used in a ring imaging Cherenkov counter. Such a system is being considered for the CLEO III upgrade.

  1. Temperature and velocity fields in natural convection by PIV and LIF

    DEFF Research Database (Denmark)

    Meyer, Knud Erik; Larsen, Poul Scheel; Westergaard, C. H.

    2002-01-01

    plate and cooled walls is 1.4×10^10. The flow is turbulent and is similar to some indoor room flows. Combined Particle Image Velocimetry (PIV) and Planar Light Induced Fluorescence (LIF) are used to measure local velocities and temperatures. Data measured in a symmetry plane parallel to a sidewall...

  2. Spectroscopic investigations of lanthanides and actinides using simultaneous LIF and photoionization techniques

    International Nuclear Information System (INIS)

    Shah, M.L.

    2017-01-01

    Laser-induced fluorescence (LIF) and laser-induced photoionization (LIP) are powerful spectroscopic techniques individually. These techniques have been used extensively for studying the atomic spectra. The potential of these two techniques increases enormously when used simultaneously because of their complimentary nature. Among these two, the resonance ionization spectroscopy is most sensitive, but in some cases the spectra obtained using this photoionization technique can provide the incomplete atomic energy levels information. The complete energy level information can be obtained when both the LIF and LIP techniques are used simultaneously. These techniques have been developed in our laboratory. By employing together both the LIF and LIP techniques for simultaneous detection and utilization of LIF and LIP signals not only helped in developing new methodologies but also helped in getting complete spectral information apart from the measurements of atomic parameters. For the first time, laser-induced fluorescence and laser-induced photoionization techniques are used simultaneously for the spectroscopic investigations of atoms of lanthanides and actinides. The density matrix (DM) formalism is used to validate the experimental results. (author)

  3. Investigation of a new LiF TLD individual dosimeter for measuring personal dose equivalent Hp(d) on different phantoms

    International Nuclear Information System (INIS)

    Jin Hua

    1993-01-01

    The paper describes the design of a new LiF TL dosimeter optimized for measuring personal dose equivalent, H p (d). The results obtained with four types of different phantoms, i.e. a PMMA slab, water slab, ICRU sphere and Alderson Rando phantom, and pertinent conversion coefficients show, that the conversion coefficients for the TE slab phantom are suitable for the calibration of TLD individual dosimeters on a PMMA slab phantom. In the energy range 17 keV to 1250 keV the energy response for H 0 (10) and H p (0.07) is within-20% to 8.4% for frontal irradiation. For angles within +- 60 degree the dosimeters indicate H p (10) within 0 to 22.5%, and H p (0.07) within-11.1% to 1.3%. respectively

  4. Directional effect on coloration in LiF crystal by H{sup +} and H{sub 2}{sup +} ion bombardment

    Energy Technology Data Exchange (ETDEWEB)

    Mingle, Gan; Naramoto, Hiroshi; Aoki, Yasushi; Yamamoto, Shunya; Jianer, Zeng; Takeshita, Hidefumi [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    In the present paper, the first results are reported about the coloration in LiF crystals induced by bombardments of single hydrogen ions (H{sup +}) and molecular hydrogen ions (H{sub 2}{sup +}) with the same velocity under the <100> aligned and random conditions. For the single hydrogen ion irradiation, the coloration is rather simple. The F-type color center absorption under the <100> aligned condition becomes larger than that under the random condition with the dose increase because of larger fraction of electronic energy loss under channeling condition. On the contrary, the coloration for the molecular ions does not show big channeling effect. In the low dose region some difference can be seen but the difference of coloration is not observed any more with the dose increase. The pronounced coloration for molecular ions under the channeling condition is observed in comparison with that for single ions. (author)

  5. Dosimetric analysis for photon and electron beams in Whole body irradiation

    International Nuclear Information System (INIS)

    Hurtado G, M.

    1998-01-01

    To initiate the Whole body irradiation as an alternative for the treatment of the hematological diseases, leukemia and assistant for the osseous marrow transplantation, it may be taken account the application of International Protocols about control and quality assurance. It is established the intercomparison by the different dosimetric methods: cylindrical ionization chambers and parallel plane, radiographic emulsion film, semiconductor diodes (Mosfet transistors) and TLD-100 thermoluminescent crystals, obtained measurements for 140 x 140 cm 2 fields and large distances 340 cm respect conventional fields in Radiotherapy. The in vitro dosimetry was realized at the Universal Anthropomorphic puppet Alderson Rando basically with the cylindrical crystals (1 mm diameter) of TLD-100 lithium fluoride. It was obtained the dose value with a 0.6 cm 3 cylindrical ionization chamber and the Farmer electrometer for Whole body irradiation (ICT) with photons for electrons and were obtained values with the Markus plane parallel camera. Knowing the dose rate value to the source-surface distance DFS= 80 cm, it was calibrated the crystals with the reference radiation beam of 60 Co for obtaining the response curve: Dose vs. Tl lecture. It was characterized the 10 % of the total population for 300 crystals for applying the statistics corresponding. The luminescence curve obtained of Gaussian form was considered satisfactory by its stability during the pre-anneal lecture and anneal process, getting the main peak lecture at 300 Centigrade according to assigned parameters at lecture equipment TLD Harshaw model 4500. The results indicate the functional dependence with the distance DFS= 340 cm for the following depth PPD, the relations TMR and TPR, the TAR is not calculated by the increment of the dispersion in air. The penumbra increment indicates an increase of the radiation field respect of luminous field. The dispersion angle q 1 respect at the field central axis was determined and was

  6. Laser induced fluorescence thermometry (LIF-T) as a non-invasive temperature measurement technique for thermal hydraulic experiments

    Energy Technology Data Exchange (ETDEWEB)

    Strack, J.; Leung, K.; Walker, A., E-mail: strackj@mcmaster.ca [McMaster Univ., Hamilton, ON (Canada)

    2014-07-01

    Laser induced fluorescence (LIF) is an experimental technique whereby a scalar field in a fluid system is measured optically from the fluorescence intensity of a tracer dye following excitation by laser light. For laser induced fluorescence thermometry (LIF-T), a temperature sensitive dye is used. Through the use of a temperature sensitive tracer dye, sheet laser optics, optical filters, and photography, a 2D temperature field can be measured non-invasively. An experiment to test the viability of using LIF-T for macroscopic thermal hydraulic experiments was developed and tested. A reference calibration curve to relate fluorescence measurements to temperature is presented. (author)

  7. Radiodiagnostics of kidneys and urinary passages - exposure to irradiation in children

    International Nuclear Information System (INIS)

    Renner, J.

    1979-01-01

    By means of thermoluminescencedosimetry the irradiation dose for the gonads was measured with LiF dosimeters in children who where subjected to infusion urograms or micturitioncystourethrograms. The dose to which the male patients were exposed was measured near the scrotum at the thigh; the dose received by the female patients was measured in the rectum. (DG) [de

  8. Laboratory LiF characterization of different phytoplankton species originating harmful blooms

    Energy Technology Data Exchange (ETDEWEB)

    Barbini, R.; Colao, F.; Fantoni, R.; Palucci, A.; Ribezzo, S. [ENEA, Centro Ricerche Frascati, Rome (Italy). Dip. Innovazione; Micheli, C. [ENEA, Centro Ricerche Casaccia, Rome (Italy). Dipt. Innovazione

    1997-11-01

    A systematic laboratory characterization of different phytoplankton cultures has been performed in combination with LiF (Laser Induced Fluorescence) measurements aimed to investigate the possibility of their remote monitoring by means of lidar fluoro sensor systems. Cultures of microalgae characterized by different pigment contents have been analyzed in the visible region upon UV laser excitation. High resolution laboratory spectra have been measured in order to obtain the fingerprint of each species. Emission wavelength related to the main pigments contribution have been identified. Detection limits of the emitted red chlorophyll signal have been evaluated for the different species after dilution in the culture medium and in real sea water. Prior to the LiF excitation aimed to the remote characterization the algal cultures were morphologically analyzed by fluorescence and scanning electron microscopy. Furthermore the relevant cell number was counted for biomass estimation, and the chlorophylls content was determined by different chemical methods.

  9. PIV and LIF study of slot continuous jet at low Reynolds number

    Directory of Open Access Journals (Sweden)

    Broučková Zuzana

    2016-01-01

    Full Text Available This study deals with a continuous jet issuing from a small narrow slot with a width of 0.36 mm. The experimental arrangement is based on the piezoelectric synthetic jet actuator studied previously for easy comparisons. The working fluid is water at room temperature. The experiments were performed using methods of particle image velocimetry (PIV and flow visualization (laser induced fluorescence, LIF. The time-mean volume flux through the exit nozzle was quantified using precise scales. The mean velocity and the Reynolds number were evaluated as Um = 0.12 m/s and Re = 90, respectively. The results of LIF and PIV techniques revealed the three-dimensional character of the flow field, namely the saddle-shape velocity profiles. This behavior is typical for steady jets from a rectangular nozzle. The obtained results were compared with previous measurements of the synthetic jet issuing from the same cavity and the slot nozzle.

  10. Study of energetic dependence of LiF TLDs for photons

    Energy Technology Data Exchange (ETDEWEB)

    Cavalieri, Tassio A.; Antunes, Paula C.G.; Paiva, Fabio; Branco, Isabela S.; Sena, Michelle K.S.; Siqueira, Paulo T.D.; Yoriyaz, Helio, E-mail: tcavalieri@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    The LiF TLDs are widely used for photon dosimetry. However, in the most case the energetic dependence of these TLDs are not taken into account. This work is a preliminary study of energetic photon dependence in LiF TLD (TLD 700, enriched with {sup 7}Li). For this study it was utilized a methodology already used in others works that seek understand the dependence energetic of TLD. It was utilized three different X-ray spectrum and a {sup 137}Cs source; Beyond the calculus utilized in previous works, it was built the calibration curve for each spectrum to see the difference in dosimetry that the energetic dependence could cause. (author)

  11. Determination of the gamma-ray flux of the stopped WWR-SM reactor by color center production in LiF

    International Nuclear Information System (INIS)

    Mussaeva, M.A.; Kalannov, M.U.; Ibragimova, E.M.; Karabaev, Kh.Kh.

    2004-01-01

    Full text: Gamma-radiation with a wide energy spectrum, accompanying neutron flux in the nuclear reactor, is known to result in radiation heating of materials. It is usually detected either by calorimetry or by an ionizing chamber maintained in the active zone while the reactor works and high-energy neutrons also contribute into ionization. The aim of this research was to separate the gamma-component from the neutron flux upon stopping the WWR-SM reactor and to determine the gamma-intensity both with the ionization chamber and the well-known dosimeter LiF crystal, and also by comparing with the effect of monochromatic 60 Co gamma-radiation of the known flux and dose. For LiF with small Z the photoelectric effect is weak, and Compton scattering prevails. Both the optical absorption and photo-luminescence techniques together with micro-hardness and X-ray diffraction analysis were used for measuring the structure defect generation rate in the irradiated crystals, which is proportional to the gamma-intensity. Fluorine vacancy trapping electron is the well-known stable F-center responsible for the isolated absorption band at 250 nm and induced by radiolysis mechanism. The sequential irradiations and measurements were done within 150 hours after the moment of the reactor quenching. The dose dependence of the absorption band was found to be linear up to the dose of 10 6 R. The F-center concentration as a measure of an accumulated dose was calculated by the Smakula formula. At higher doses another band at 440 nm appears like that for 60 Co irradiation, which is responsible for unstable F 2 and F 3 centers formed due to coagulation of F-centers. X-diffraction analysis revealed twin structure in (111) plane. Yet the micro-hardness of the gamma-irradiated samples did not change noticeably. For higher doses the photo-luminescence band at 650 nm was also used as a dosimetric item. The luminescence kinetics has a fast nanosecond scale component and a weak tail in a microsecond

  12. OODR-LIF experiments on N2(A3 u+) in volume and in surface atmospheric pressure DBDs

    Czech Academy of Sciences Publication Activity Database

    DeBenedictis, S.; Ambrico, P. F.; Dilecce, G.; Šimek, Milan

    2006-01-01

    Roč. 51, č. 5 (2006), s. 24 ISSN 0003-0503. [Annual Gaseous Electronic Conference/59nd./. Columbus,Ohio, USA, 10.10.2006-13.10.2006] R&D Projects: GA AV ČR IAA1043403 Institutional research plan: CEZ:AV0Z20430508 Keywords : DBD * streamer * LIF * OODR-LIF * emission * nitrogen Subject RIV: BL - Plasma and Gas Discharge Physics

  13. The determination of kinetic parameters of LiF : Mg,Ti from thermal decaying curves of optical absorption bands

    CERN Document Server

    Yazici, A N

    2003-01-01

    In this paper, the thermal bleaching curves (TBCs) of specific optical absorption bands of LiF : Mg,Ti were measured as a function of temperature. The TBCs obtained were analysed to extract the kinetic parameters (the thermal activation energy (E) and the frequency factor (s)) of some TL glow peaks of LiF : Mg,Ti on the basis of the developed first-order kinetic model over a specified temperature region.

  14. Point and planar LIF for velocity-concentration correlations in a jet in cross flow

    DEFF Research Database (Denmark)

    Meyer, Knud Erik; Özcan, Oktay; Larsen, Poul Scheel

    2002-01-01

    Simultaneous measurements of velocities and concentration with Planar Laser Induced Fluorescense (PLIF) combined with Particle Image Velocimetry (PIV) are compared to similar measurements with pointwise Laser Induced Fluorescense (LIF) made with a slightly modified standard Laser Doppler Anemometer......, since these involve areas with high velocity- and concentration gradients, which in turn amplifies the effect of a finite measurement volume in the two measurement systems. In addition, the concentration measurement was realized by injecting clean water into the dye seeded main flow. This "inverse...

  15. Raman spectra of Au nanoparticles in polycrystalline LiF film

    International Nuclear Information System (INIS)

    Kurbatova, N.V.; Galyautdinov, M.F.; Stepanov, A.L.; Ivanov, N.A.; Kolesnikov, S.S.; Papernyj, V.L.

    2011-01-01

    The modification of the size of gold nanoparticles in LiF matrix during laser annealing was studied fort he first time by Raman spectroscopy. Laser annealing was carried out at the wavelength of the plasmon absorption of gold nanoparticles. The experimental spectra were compared with the calculated modes of in-phase bending vibrations in nanoparticles. The observed effects were discussed from the standpoint of the size quantization of acoustic vibrations in nanostructures. (authors)

  16. Fading of LiF and CaF2:Dy

    International Nuclear Information System (INIS)

    Ben-Shachar, B.; German, U.; Weiser, G.

    1983-03-01

    The fading of LiF and CaF 2 :Dy was investigated and the results were compared to the literature. The effect of thermal annealing was studied in order to reduce the fading in both phosphors and to minimize the effects of the environment on CaF 2 :Dy. Minimizing the fading and knowing its time dependence make possible the exact personal and environmental dosimetry. (Author)

  17. Properties of the 4.45 eV optical absorption band in LiF:Mg, Ti

    International Nuclear Information System (INIS)

    Nail, I.; Oster, L.; Horowitz, Y. S.; Biderman, S.; Belaish, Y.

    2006-01-01

    The optical absorption (OA) and thermoluminescence (TL) of dosimetric LiF:Mg,Ti (TLD-100) as well as nominally pure LiF single crystal have been studied as a function of irradiation dose, thermal and optical bleaching in order to investigate the role of the 4.45 eV OA band in low temperature TL. Computerised deconvolution was used to resolve the absorption spectrum into individual gaussian bands and the TL glow curve into glow peaks. Although the 4.45 eV OA band shows thermal decay characteristics similar to the 4.0 eV band its dose filling constant and optical bleaching properties suggest that it cannot be associated with the TL of composite peaks 4 or 5. Its presence in optical grade single crystal LiF further suggests that it is an intrinsic defect or possibly associated with chance impurities other than Mg, Ti. (authors)

  18. Dosimetric intercomparison in Cobalt 60 unities using TLD-100 crystals and CaSO{sub 4}: Dy + Ptfe; Intercomparacion dosimetrica en unidades de cobalto 60 usando cristales de TLD-100 y CaSO{sub 4}: Dy + PTFE

    Energy Technology Data Exchange (ETDEWEB)

    Gaona, E. [Universidad Autonoma Metropolitana Xochimilco, Mexico D.F. (Mexico); Azorin N, J. [Universidad Autonoma Metropolitana Iztapalapa, Mexico D.F. (Mexico); Perez P, M.A. [Instituto Nacional de Cancerologia, Mexico D.F. (Mexico); Castillo H, M. [Centro Medico Nacional 20 de Noviembre, ISSSTE, Mexico D.F. (Mexico); Flores F, F. [Unidad de Oncologia, Centro Medico Nacional, IMSS, Mexico D.F. (Mexico); Guzman R, L.V. [Unidad de Oncologia, Hospital General de Mexico, Mexico D.F. (Mexico)

    1999-07-01

    The purpose of this work is to design and construct a phantom in basis of thermoplastic polymer of methyl methacrylate that is reutilizable and which allows to do an analysis of the absorbed doses in thermoluminescent crystals (Tl) exposed to cobalt 60 to establish the dosimetric intercomparison in cobalt units which allows to do the follow-up of the Quality assurance programs, standardization of calibration procedures, dosimetry and TLD post intercomparison in radiotherapy. This work allows also prove new thermoluminescent materials of national manufacture developed by Juan Azorin and collaborators as the CaSO{sub 4}: Dy + Ptfe. This is a first study which is realized in Mexico with the system crystal-phantom for aims to intercomparison in cobalt 60 units. In this work participate eight unities of cobalt 60 of different trades belonging at four radiotherapy centers. The results of the dose intercomparison of the eight unities of cobalt 60 were in the range 0.95-1.13, taking in account that the values between 0.95 and 1.05 were considered acceptable in terms of the requirements by the standing legislation. (Author)

  19. Trace determination of Pu by LIF in an inductively coupled plasma

    International Nuclear Information System (INIS)

    Mauchien, P.; Briand, A.; Moulin, C.

    1989-01-01

    Inductively Coupled Plasma/Emission Spectrometry (ICP/ES) technique is largely used in the nuclear industry as an elementary analytical technique. Nevertheless, when the sample to analyse presents elements with a lot of emission spectral lines, spectral interferences lead to limited sensitivity. This is the case for Pu determination in presence of large U concentration. In pure aqueous solution, the limit of detection (LOD) for Pu is 10 μg/1. In presence of U, the LOD is determined by a ratio U/Pu = 1000. Pulsed Laser Induced Fluorescence (LIF) spectrometry is known to be a very selective technique when associated with an Inductively Coupled Plasma source. The absolute sensitivity is better by 2 or 3 orders of magnitude; its principle is based on selective excitation of the ionic species in the plasma followed by fluorescence radiation detection of these species; this radiation being practically free from spectral interferences, it is possible to improve the relative LOD. In this presentation, experimental results performed at Cogema/Marcoule laboratory are presented. After the experimental set-up description, first results of LIF are shown: - very good selectivity is effectively obtained, - a series of analytical results obtained with excitation scanning from the visible to the U.V. show that sensitivity of LIF technique is strictly related to the spectroscopic scheme

  20. Influence of defects on the thermal conductivity of compressed LiF

    Science.gov (United States)

    Jones, R. E.; Ward, D. K.

    2018-02-01

    Defect formation in LiF, which is used as an observation window in ramp and shock experiments, has significant effects on its transmission properties. Given the extreme conditions of the experiments it is hard to measure the change in transmission directly. Using molecular dynamics, we estimate the change in conductivity as a function of the concentration of likely point and extended defects using a Green-Kubo technique with careful treatment of size effects. With this data, we form a model of the mean behavior and its estimated error; then, we use this model to predict the conductivity of a large sample of defective LiF resulting from a direct simulation of ramp compression as a demonstration of the accuracy of its predictions. Given estimates of defect densities in a LiF window used in an experiment, the model can be used to correct the observations of thermal energy through the window. In addition, the methodology we develop is extensible to modeling, with quantified uncertainty, the effects of a variety of defects on the thermal conductivity of solid materials.

  1. Dysregulated LIF-STAT3 pathway is responsible for impaired embryo implantation in a Streptozotocin-induced diabetic mouse model

    Directory of Open Access Journals (Sweden)

    Tong-Song Wang

    2015-07-01

    Full Text Available The prevalence of diabetes is increasing worldwide with the trend of patients being young and creating a significant burden on health systems, including reproductive problems, but the effects of diabetes on embryo implantation are still poorly understood. Our study was to examine effects of diabetes on mouse embryo implantation, providing experimental basis for treating diabetes and its complications. Streptozotocin (STZ was applied to induce type 1 diabetes from day 2 of pregnancy or pseudopregnancy in mice. Embryo transfer was used to analyze effects of uterine environment on embryo implantation. Our results revealed that the implantation rate is significantly reduced in diabetic mice compared to controls, and the change of uterine environment is the main reason leading to the decreased implantation rate. Compared to control, the levels of LIF and p-STAT3 are significantly decreased in diabetic mice on day 4 of pregnancy, and serum estrogen level is significantly higher. Estrogen stimulates LIF expression under physiological level, but the excessive estrogen inhibits LIF expression. LIF, progesterone or insulin supplement can rescue embryo implantation in diabetic mice. Our data indicated that the dysregulated LIF-STAT3 pathway caused by the high level of estrogen results in the impaired implantation in diabetic mice, which can be rescued by LIF, progesterone or insulin supplement.

  2. Dosimetric intercomparison in Cobalt 60 unities using TLD-100 crystals and CaSO4: Dy + Ptfe

    International Nuclear Information System (INIS)

    Gaona, E.; Azorin N, J.; Perez P, M.A.; Castillo H, M.; Flores F, F.; Guzman R, L.V.

    1999-01-01

    The purpose of this work is to design and construct a phantom in basis of thermoplastic polymer of methyl methacrylate that is reutilizable and which allows to do an analysis of the absorbed doses in thermoluminescent crystals (Tl) exposed to cobalt 60 to establish the dosimetric intercomparison in cobalt units which allows to do the follow-up of the Quality assurance programs, standardization of calibration procedures, dosimetry and TLD post intercomparison in radiotherapy. This work allows also prove new thermoluminescent materials of national manufacture developed by Juan Azorin and collaborators as the CaSO 4 : Dy + Ptfe. This is a first study which is realized in Mexico with the system crystal-phantom for aims to intercomparison in cobalt 60 units. In this work participate eight unities of cobalt 60 of different trades belonging at four radiotherapy centers. The results of the dose intercomparison of the eight unities of cobalt 60 were in the range 0.95-1.13, taking in account that the values between 0.95 and 1.05 were considered acceptable in terms of the requirements by the standing legislation. (Author)

  3. 3D Stagnation instabilities in MagLIF loads on the Z Generator

    Science.gov (United States)

    Jennings, Christopher

    2017-10-01

    Experiments with Magnetized Liner Inertial Fusion (MagLIF) loads have successfully demonstrated the premise of magnetized fusion. While these experiments are increasingly well diagnosed, many of the measurements (particularly during stagnation) are time integrated, limited in spatial resolution or require additional assumptions to interpret in the context of a structured, rapidly evolving system. As such, there is some ambiguity over what may be limiting performance. Poor laser coupling in preheating the fuel prior to implosion has been suggested as a mechanism. Mix of high Z contaminants that cool the fuel is also a significant concern. In addition, time integrated crystal imaging has shown significant structure in the final fuel assembly indicating potential disruption from instabilities. Understanding the balance between these degradation mechanisms is vital to progress with MagLif. We compare several sets of experimental data with synthetically generated data from systematically varied 3D resistive-MHD simulations to gain insight into the relative contributions of different degradation mechanisms. We demonstrate how some measurements strongly indicate disruption from liner material penetrating into the fuel at stagnation, and discuss the implications this has for how MagLif targets work and scale to larger drive currents. We then explore the extent to which different combinations of instability development, current delivery, high-Z mix into the fuel and initial laser deposition can be differentiated in our existing measurements. Better determining the dominant degradation mechanisms can directly influence the direction we take to improve performance, or our confidence in scaling these targets to higher currents. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology and Engineering Solutions of Sandia LLC, a wholly owned subsidiary of Honeywell International Inc. for the U.S. DoE's NNSA under contract DE-NA0003525.

  4. LiF Reduces MICs of Antibiotics against Clinical Isolates of Gram-Positive and Gram-Negative Bacteria

    Directory of Open Access Journals (Sweden)

    H. C. Syed

    2012-01-01

    Full Text Available Antibiotic resistance is an ever-growing problem yet the development of new antibiotics has slowed to a trickle, giving rise to the use of combination therapy to eradicate infections. The purpose of this study was to evaluate the combined inhibitory effect of lithium fluoride (LiF and commonly used antimicrobials on the growth of the following bacteria: Enterococcus faecalis, Staphyloccoccus aureus, Escherichia coli, Pseudomonas aeruginosa, Acinetobacter baumannii, Klebsiella pneumoniae, Serratia marcescens, and Streptococcus pneumoniae. The in vitro activities of ceftazidime, sulfamethoxazole-trimethoprim, streptomycin, erythromycin, amoxicillin, and ciprofloxacin, doxycycline, alone or combined with LiF were performed by microdilution method. MICs were determined visually following 18–20 h of incubation at 37°C. We observed reduced MICs of antibiotics associated with LiF ranging from two-fold to sixteen-fold. The strongest decreases of MICs observed were for streptomycin and erythromycin associated with LiF against Acinetobacter baumannii and Streptococcus pneumoniae. An eight-fold reduction was recorded for streptomycin against S. pneumoniae whereas an eight-fold and a sixteen-fold reduction were obtained for erythromycin against A. baumannii and S. pneumoniae. This suggests that LiF exhibits a synergistic effect with a wide range of antibiotics and is indicative of its potential as an adjuvant in antibiotic therapy.

  5. A positronium beam and positronium reflection from LiF(100)

    International Nuclear Information System (INIS)

    Weber, M.; Tang, S.; Berko, S.; Brown, B.L.; Canter, K.F.; Lynn, K.G.; Mills, A.P. Jr.; Roellig, L.O.; Viescas, A.J.

    1988-01-01

    We report results obtained from a variable energy monoenergetic beam of positronium (Ps). Ps was formed by a charge transfer reaction of positrons colliding with Ar gas atoms in a ''gas cell'' with an efficiency of about 3 /times/ 10/sup /minus/4/. The beam was used to measure the fraction, R, of specularly reflected ortho-Ps from LiF(100). We found R to peak at about 30% for 7 eV Ps at a specular scattering angle of 50/degree/ to 60/degree/. At higher energies R drops sharply to values around 0.5% near 60 eV Ps

  6. Calculation of hyperfine constants for the H center in LiF

    International Nuclear Information System (INIS)

    Alencar, P.T.S.

    1975-01-01

    The EPR and the ENDOR hyperfine parameters for the H center in LiF are calculated assuming that the F - 2 central molecule is a simplified model for the electronic structure of this deffect. The best theoretical fitting was obtained by relaxing the ions neighboring the central molecule. We have obtained relaxations which are in agreement with the physical nature of this deffect, but for some ions the results have shown that a better wave functions for the unpaired electrons must be used. The results and the limitations of the suggested model, are discussed proposing a more realistic description for the deffect, than the F - 2 central molecule model

  7. measurement of the supralinearity of 7LiF thermoluminescent dosimeters

    International Nuclear Information System (INIS)

    Hancock, I.B.

    1978-04-01

    A study has been made of the supralinearity of the 7 LiF thermoluminesecent dosimeter (T.L.D.) used in the UKAEA personnel criticality dosimeter by exposure to a 60 Co source. the response of the T.L.D. was linear up to approximately 450 rad, above which it became increasingly supralinear, over-reading by about 50% at 2000 rad. The results have been used to produce a correction graph, as a function of apparent dose up to 3500 rad, for routine use in nuclear accident dosimetry. (author)

  8. Charge-state related effects in sputtering of LiF by swift heavy ions

    Energy Technology Data Exchange (ETDEWEB)

    Assmann, W. [Ludwig-Maximilians-Universität München, 85748 Garching (Germany); Ban-d' Etat, B. [Centre de Recherche sur les Ions, les Matériaux et la photonique, CIMAP-GANIL, CEA–CNRS–ENSICAEN–Univ. Caen, 14070 Caen (France); Bender, M. [GSI Helmholtzzentrum für Schwerionenforschung, 64291 Darmstadt (Germany); Boduch, P. [Centre de Recherche sur les Ions, les Matériaux et la photonique, CIMAP-GANIL, CEA–CNRS–ENSICAEN–Univ. Caen, 14070 Caen (France); Grande, P.L. [Univ. Fed. Rio Grande do Sul, BR-91501970 Porto Alegre, RS (Brazil); Lebius, H.; Lelièvre, D. [Centre de Recherche sur les Ions, les Matériaux et la photonique, CIMAP-GANIL, CEA–CNRS–ENSICAEN–Univ. Caen, 14070 Caen (France); Marmitt, G.G. [Univ. Fed. Rio Grande do Sul, BR-91501970 Porto Alegre, RS (Brazil); Rothard, H. [Centre de Recherche sur les Ions, les Matériaux et la photonique, CIMAP-GANIL, CEA–CNRS–ENSICAEN–Univ. Caen, 14070 Caen (France); Seidl, T.; Severin, D.; Voss, K.-O. [GSI Helmholtzzentrum für Schwerionenforschung, 64291 Darmstadt (Germany); Toulemonde, M., E-mail: toulemonde@ganil.fr [Centre de Recherche sur les Ions, les Matériaux et la photonique, CIMAP-GANIL, CEA–CNRS–ENSICAEN–Univ. Caen, 14070 Caen (France); Trautmann, C. [GSI Helmholtzzentrum für Schwerionenforschung, 64291 Darmstadt (Germany); Technische Universität Darmstadt, 64289 Darmstadt (Germany)

    2017-02-01

    Sputtering experiments with swift heavy ions in the electronic energy loss regime were performed by using the catcher technique in combination with elastic recoil detection analysis. The angular distribution of particles sputtered from the surface of LiF single crystals is composed of a jet-like peak superimposed on a broad isotropic distribution. By using incident ions of fixed energy but different charges states, the influence of the electronic energy loss on both components is probed. We find indications that isotropic sputtering originates from near-surface layers, whereas the jet component may be affected by contributions from depth up to about 150 nm.

  9. Effect of divalent impurities on some physical properties of LiF and NaF; Influence des impuretes divalentes sur quelques proprietes physiques du LiF et du NaF

    Energy Technology Data Exchange (ETDEWEB)

    Laj, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-05-01

    The ionic thermo-currents technique is applied to the study of impurity vacancy dipoles in LiF and NaF doped with several divalent cations. In LiF only one ITC band is observed whatever the impurity studied. In NaF on the contrary two ITC bands are present, one corresponding to the one observed in LiF, the other one, intense in the case of small impurities, at lower temperature. A parallel EPR study in the case of Mn{sup 2+} doped samples shows that the band observed in LiF and the corresponding one in NaF are due to the relaxation of dipoles formed by the association of an impurity and a vacancy in the next nearest position. The knowledge of the properties of the dipoles allows to show that the room temperature ionic conductivity of LiF is conditioned by the equilibrium: M{sup ++} {open_square}+ {yields} M{sup ++} + {open_square}+. It is also shown that the isolated cation vacancy originating from this dissociation is responsible for the enhancement of {gamma}-ray coloration of LiF doped with divalent cation impurities. A paramagnetic center ascribed to the presence of Mn{sup 0} isolated in the lattice is also studied. The value of the hyperfine interaction and its temperature dependence are in good agreement with both the theory and the other experimental results. Finally it is shown that the disappearance of dipoles by annealing is related to the formation of complexes involving OH{sup -} ions, probably of the M(OH){sub 2} type, with the two OH{sup -} ions occupying a single fluorine site. (author) [French] La technique des thermocourants ioniques est appliquee a l'etude des dipoles lacune-impurete dans LiF et NaF dopes avec plusieurs cations divalents. Dans LiF on met en evidence un seul pic de thermocourant quelle que soit l'impurete consideree. Dans NaF au contraire deux pics de thermocourants sont presents, l'un correspondant a celui observe dans LiF, l'autre, dominant dans le cas des impuretes de petite taille, a plus basse temperature. Une etude parallelle

  10. Effect of divalent impurities on some physical properties of LiF and NaF; Influence des impuretes divalentes sur quelques proprietes physiques du LiF et du NaF

    Energy Technology Data Exchange (ETDEWEB)

    Laj, C. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-05-01

    The ionic thermo-currents technique is applied to the study of impurity vacancy dipoles in LiF and NaF doped with several divalent cations. In LiF only one ITC band is observed whatever the impurity studied. In NaF on the contrary two ITC bands are present, one corresponding to the one observed in LiF, the other one, intense in the case of small impurities, at lower temperature. A parallel EPR study in the case of Mn{sup 2+} doped samples shows that the band observed in LiF and the corresponding one in NaF are due to the relaxation of dipoles formed by the association of an impurity and a vacancy in the next nearest position. The knowledge of the properties of the dipoles allows to show that the room temperature ionic conductivity of LiF is conditioned by the equilibrium: M{sup ++} {open_square}+ {yields} M{sup ++} + {open_square}+. It is also shown that the isolated cation vacancy originating from this dissociation is responsible for the enhancement of {gamma}-ray coloration of LiF doped with divalent cation impurities. A paramagnetic center ascribed to the presence of Mn{sup 0} isolated in the lattice is also studied. The value of the hyperfine interaction and its temperature dependence are in good agreement with both the theory and the other experimental results. Finally it is shown that the disappearance of dipoles by annealing is related to the formation of complexes involving OH{sup -} ions, probably of the M(OH){sub 2} type, with the two OH{sup -} ions occupying a single fluorine site. (author) [French] La technique des thermocourants ioniques est appliquee a l'etude des dipoles lacune-impurete dans LiF et NaF dopes avec plusieurs cations divalents. Dans LiF on met en evidence un seul pic de thermocourant quelle que soit l'impurete consideree. Dans NaF au contraire deux pics de thermocourants sont presents, l'un correspondant a celui observe dans LiF, l'autre, dominant dans le cas des impuretes de petite taille, a plus basse temperature

  11. Detection of irradiation history of seasoning mixes composed of dried fish and its extract. TL analysis and application considerations for mineral separation from foods

    International Nuclear Information System (INIS)

    Sekiguchi, Masayuki; Nakagawa, Seiko; Yunoki, Syunji

    2009-01-01

    In the present study, the thermoluminescence (TL) method (EN1788) was used to detect the irradiation treatment of Japanese traditional seasoning mixes mainly composed of dried fish (bonito etc.) and its extract. The Glow 1 curves of minerals separated from the seasoning mixes using a heavy liquid showed significant single peaks at temperatures between 146.5degC and 175.4degC. The peaks are typical for irradiated food, despite the samples being not irradiated. The Glow 2 curves showed single peaks at temperatures higher than that of the Glow 1 curves (175.4degC to 217.9degC). The peak temperature of Glow 2 is usually lower than that of Glow 1 because the peaks from irradiated silicate minerals shift to higher temperatures with time. The TL glow ratios (Glow1/Glow2) calculated in the temperature ranges (167-232degC) defined by means of irradiated TLD-100 were above 0.1, suggesting that the mineral samples were contaminated with organic materials such as protein or bio-inorganic materials such as bone. In order to remove the possible contaminants, acid hydrolysis and subsequent heavy liquid separation were employed. The minerals thus obtained showed no Glow 1 peaks. A significant peak was observed at 213degC instead of peaks at lower temperature for the case of irradiated seasoning mixes (2.45 kGy). These results suggest that the TL method may provide false positives for the Japanese traditional seasoning mixes because of luminescence from some components other than silicate minerals. It appears that EN1788 needs some modification to precisely detect food irradiation for the seasoning mixes. (author)

  12. The fast neutron response of 7LiF thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Knipe, A.D.

    1990-02-01

    A series of experiments was performed in 1982 to determine the neutron energy response of the 7 LiF thermoluminescent dosemeter (TLD) employed in European zero power fast reactor gamma-ray energy deposition studies. Preliminary results of this work were included in a 1985 International experimental data-base of TLD neutron sensitivities and provided the most consistent set of data within the 7 LiF compilation. A more detailed interpretation of these data has improved the results still further, giving a mean relative neutron to gamma efficiency of 0.118±0.005. The main objective of this re-evaluation was to establish recommended neutron energy response values to replace a 1974 data set for the analysis of in-core fast reactor measurements. This was achieved by combining the mean experimental relative efficiency of 0.118 with calculated energy dependent kerma factors. The kerma factors for the TLD were based on US National Bureau of Standards values and a composition determined by chemical analysis. Adoption of the revised neutron energy response data set produces a small increase in the measured gamma-ray energy deposition of typically 2% relative to the 1974 data. However, more importantly, the detailed analysis of the experimental response data has significantly improved confidence in the neutron corrections applied to in-core TLD gamma-ray energy deposition measurements. (author)

  13. Uniformity and stability of LiF sensitivity - a review of fourteen years' monitoring experience

    International Nuclear Information System (INIS)

    Grogan, D.; Bradley, R.P.; Mattioli, A.

    1990-01-01

    The Personnel Dosimetry Services of the Bureau of Radiation and Medical Devices have utilised an increasingly large pool of thermoluminescence dosimetry (TLD) plaques since 1976. Between 1975 and 1981, the volume increased from 60,000 to 180,000 to implement a change from films to TLDs. As of 1989, 317,000 plaques are in service. Most, but not all, of the thick and thin LiF-100 chips contained on each dosemeter plaque have been individually calibrated. Because the TLDs have been obtained over a period of fourteen years, it is possible to quantify the variation of response sensitivities for each batch purchased. A continued increase in sensitivity has been noted. Furthermore, because detailed records of use have been maintained, it is also possible to quantify information relating the purchased batch sensitivities to other parameters such as cumulative exposure, time of use, and number of readings. Some selected examples are given. Of most interest is the variation of sensitivity factors for individual LiF crystals in relation to the above parameters. Results for periods of one to fourteen years are presented. (author)

  14. Ceramic thick film humidity sensor based on MgTiO3 + LiF

    International Nuclear Information System (INIS)

    Kassas, Ahmad; Bernard, Jérôme; Lelièvre, Céline; Besq, Anthony; Guhel, Yannick; Houivet, David; Boudart, Bertrand; Lakiss, Hassan; Hamieh, Tayssir

    2013-01-01

    Graphical abstract: - Highlights: • The fabricated sensor based on MgTiO 3 + LiF materials used the spin coating technology. • The response time is 70 s to detect variation between 5 and 95% relative humidity. • The addition of Scleroglucan controls the viscosity and decreases the roughness of thick film surface. • This humidity sensor is a promising, low-cost, high-quality, reliable ceramic films, that is highly sensitive to humidity. - Abstract: The feasibility of humidity sensor, consisting of a thick layer of MgTiO 3 /LiF materials on alumina substrate, was studied. The thermal analysis TGA-DTGA and dilatometric analysis worked out to confirm the sintering temperature. An experimental plan was applied to describe the effects of different parameters in the development of the thick film sensor. Structural and microstructural characterizations of the developed thick film were made. Rheological study with different amounts of a thickener (scleroglucan “sclg”), showing the behavior variation, as a function of sclg weight % was illustrated and rapprochement with the results of thickness variation as a function of angular velocity applied in the spin coater. The electrical and dielectric measurements confirmed the sensitivity of the elaborated thick film against moisture, along with low response time

  15. Ceramic thick film humidity sensor based on MgTiO{sub 3} + LiF

    Energy Technology Data Exchange (ETDEWEB)

    Kassas, Ahmad, E-mail: a.kassas.mcema@ul.edu.lb [Faculty of Agricultural Engineering and Veterinary Medicine, Laboratory of Materials, Catalysis, Environment and Analytical Methods (MCEMA), Faculty of Sciences and Doctoral School of Sciences and Technology (EDST), Lebanese University, Hariri Campus, Hadath, Beirut (Lebanon); Laboratoire Universitaire des Sciences Appliquées de Cherbourg (LUSAC), 50130 Cherbourg-Octeville (France); Bernard, Jérôme; Lelièvre, Céline; Besq, Anthony; Guhel, Yannick; Houivet, David; Boudart, Bertrand [Laboratoire Universitaire des Sciences Appliquées de Cherbourg (LUSAC), 50130 Cherbourg-Octeville (France); Lakiss, Hassan [Faculty of Agricultural Engineering and Veterinary Medicine, Laboratory of Materials, Catalysis, Environment and Analytical Methods (MCEMA), Faculty of Sciences and Doctoral School of Sciences and Technology (EDST), Lebanese University, Hariri Campus, Hadath, Beirut (Lebanon); Faculty of Engineering, Section III, Hariri Campus, Hadath, Beirut (Lebanon); Hamieh, Tayssir [Faculty of Agricultural Engineering and Veterinary Medicine, Laboratory of Materials, Catalysis, Environment and Analytical Methods (MCEMA), Faculty of Sciences and Doctoral School of Sciences and Technology (EDST), Lebanese University, Hariri Campus, Hadath, Beirut (Lebanon)

    2013-10-15

    Graphical abstract: - Highlights: • The fabricated sensor based on MgTiO{sub 3} + LiF materials used the spin coating technology. • The response time is 70 s to detect variation between 5 and 95% relative humidity. • The addition of Scleroglucan controls the viscosity and decreases the roughness of thick film surface. • This humidity sensor is a promising, low-cost, high-quality, reliable ceramic films, that is highly sensitive to humidity. - Abstract: The feasibility of humidity sensor, consisting of a thick layer of MgTiO{sub 3}/LiF materials on alumina substrate, was studied. The thermal analysis TGA-DTGA and dilatometric analysis worked out to confirm the sintering temperature. An experimental plan was applied to describe the effects of different parameters in the development of the thick film sensor. Structural and microstructural characterizations of the developed thick film were made. Rheological study with different amounts of a thickener (scleroglucan “sclg”), showing the behavior variation, as a function of sclg weight % was illustrated and rapprochement with the results of thickness variation as a function of angular velocity applied in the spin coater. The electrical and dielectric measurements confirmed the sensitivity of the elaborated thick film against moisture, along with low response time.

  16. Sputtering from swift-ion trails in LiF: A hybrid PIC/MD simulation

    Energy Technology Data Exchange (ETDEWEB)

    Cherednikov, Yaroslav; Sun, Si Neng; Urbassek, Herbert M., E-mail: urbassek@rhrk.uni-kl.de

    2013-11-15

    We model the sputtering of a LiF crystal induced by swift-ion impact. The impinging ion creates a trail of doubly ionized F{sup +} ions, while simultaneously the corresponding electrons are set free. Ions move according to molecular dynamics, while excited electrons are treated by a particle-in-cell scheme. We treat the recombination time of electrons as a free parameter in our model. We find that the energy distribution of sputtered ions consists of 2 groups: a low-energy group centered at <1 eV, and a high-energy group at 7–8 eV. Fast ions (mainly Li{sup +}) are emitted early; these charge the surface negatively. Later, larger cluster ions and also neutral LiF molecules are emitted. Emission occurs at low angles to the surface normal. A jet along the normal direction can be observed, which is due to the electric field building up at the track surface. With increasing recombination time, processes are colder; sputtering decreases and the non-thermal jet structure becomes stronger.

  17. Peak frequency and linewidth of the optical bands of F2 and F3+ centers in Lif

    International Nuclear Information System (INIS)

    Baldacchini, G.; De Nicola, E.; Montereali, R.M.; Scacco, A.; Kalinov, V.

    1999-01-01

    Optical absorption and emission spectra have been measured in LiF crystals colored with γ ray. The optical bands of various samples, suitably treated in order to create different relative concentrations of F 2 and F 3 + defects in the crystal lattice, have been studied in detail at 77 K and at room temperature, and resolved into their components. An accurate determination of the spectroscopic parameters of the absorption and emission bands of the aggregated defects in LiF has been achieved, and a critical comparison with previous data has been performed [it

  18. Dosimetric analysis for photon and electron beams in Whole body irradiation; Analisis dosimetrico para haces de fotones y electrones en irradiacion corporal total

    Energy Technology Data Exchange (ETDEWEB)

    Hurtado G, M [Posgrado. Fisica Medica Radiologica. Universidad Nacional de Colombia, Bogota. Instituto Nacional de Cancerologia. Instituto Regional de Cancer de la Orinoquia. Hospital Regional de Villavicencio, Meta (Colombia)

    1999-12-31

    To initiate the Whole body irradiation as an alternative for the treatment of the hematological diseases, leukemia and assistant for the osseous marrow transplantation, it may be taken account the application of International Protocols about control and quality assurance. It is established the intercomparison by the different dosimetric methods: cylindrical ionization chambers and parallel plane, radiographic emulsion film, semiconductor diodes (Mosfet transistors) and TLD-100 thermoluminescent crystals, obtained measurements for 140 x 140 cm{sup 2} fields and large distances 340 cm respect conventional fields in Radiotherapy. The in vitro dosimetry was realized at the Universal Anthropomorphic puppet Alderson Rando basically with the cylindrical crystals (1 mm diameter) of TLD-100 lithium fluoride. It was obtained the dose value with a 0.6 cm{sup 3} cylindrical ionization chamber and the Farmer electrometer for Whole body irradiation (ICT) with photons for electrons and were obtained values with the Markus plane parallel camera. Knowing the dose rate value to the source-surface distance DFS= 80 cm, it was calibrated the crystals with the reference radiation beam of {sup 60} Co for obtaining the response curve: Dose vs. Tl lecture. It was characterized the 10 % of the total population for 300 crystals for applying the statistics corresponding. The luminescence curve obtained of Gaussian form was considered satisfactory by its stability during the pre-anneal lecture and anneal process, getting the main peak lecture at 300 Centigrade according to assigned parameters at lecture equipment TLD Harshaw model 4500. The results indicate the functional dependence with the distance DFS= 340 cm for the following depth PPD, the relations TMR and TPR, the TAR is not calculated by the increment of the dispersion in air. The penumbra increment indicates an increase of the radiation field respect of luminous field. The dispersion angle q{sub 1} respect at the field central axis

  19. Dosimetric analysis for photon and electron beams in Whole body irradiation; Analisis dosimetrico para haces de fotones y electrones en irradiacion corporal total

    Energy Technology Data Exchange (ETDEWEB)

    Hurtado G, M. [Posgrado. Fisica Medica Radiologica. Universidad Nacional de Colombia, Bogota. Instituto Nacional de Cancerologia. Instituto Regional de Cancer de la Orinoquia. Hospital Regional de Villavicencio, Meta (Colombia)

    1998-12-31

    To initiate the Whole body irradiation as an alternative for the treatment of the hematological diseases, leukemia and assistant for the osseous marrow transplantation, it may be taken account the application of International Protocols about control and quality assurance. It is established the intercomparison by the different dosimetric methods: cylindrical ionization chambers and parallel plane, radiographic emulsion film, semiconductor diodes (Mosfet transistors) and TLD-100 thermoluminescent crystals, obtained measurements for 140 x 140 cm{sup 2} fields and large distances 340 cm respect conventional fields in Radiotherapy. The in vitro dosimetry was realized at the Universal Anthropomorphic puppet Alderson Rando basically with the cylindrical crystals (1 mm diameter) of TLD-100 lithium fluoride. It was obtained the dose value with a 0.6 cm{sup 3} cylindrical ionization chamber and the Farmer electrometer for Whole body irradiation (ICT) with photons for electrons and were obtained values with the Markus plane parallel camera. Knowing the dose rate value to the source-surface distance DFS= 80 cm, it was calibrated the crystals with the reference radiation beam of {sup 60} Co for obtaining the response curve: Dose vs. Tl lecture. It was characterized the 10 % of the total population for 300 crystals for applying the statistics corresponding. The luminescence curve obtained of Gaussian form was considered satisfactory by its stability during the pre-anneal lecture and anneal process, getting the main peak lecture at 300 Centigrade according to assigned parameters at lecture equipment TLD Harshaw model 4500. The results indicate the functional dependence with the distance DFS= 340 cm for the following depth PPD, the relations TMR and TPR, the TAR is not calculated by the increment of the dispersion in air. The penumbra increment indicates an increase of the radiation field respect of luminous field. The dispersion angle q{sub 1} respect at the field central axis

  20. Determination of absorbed dose in crystalline and thyroid gland with irradiation protocols applied in orthopantomography equipment for dental examination

    International Nuclear Information System (INIS)

    Munoz A, A. A.; Ramirez A, L. M.; Sosa A, M. A.; Azorin V, J. C.; Vallejo H, M. A.

    2016-10-01

    Ionizing radiations are very useful in the medical field for the diagnostic use of different pathologies. Currently there are different technologies for diagnostic imaging using conventional X-ray, computed tomography, mammography, angiography, dental panoramic X-ray, among others. However, it should be noted that exposure to radiation in this type of diagnostic tests has increased considerably in recent years, because radiological examinations are not always carried out according to the actual clinical needs of each patient, increasing the risk to develop cancer. In this paper, the absorbed dose in the lens and thyroid gland was measured with the help of TLD-100 dosimeters located in a PMMA phantom adapted for orthopantomography (dental panoramic X-ray) equipment in 5 hospitals; using the parameters pre-configured for normal adult for irradiation. A Harshaw 3500 equipment was used to read the dosimeters, obtaining a value of 1.324 ± Sd 0.01 mGy for crystalline and 1.044 ± Sd 0.03 mGy values which are intended to be validated under other conditions and protocols. (Author)

  1. Definition of the dose(tempo)-distribution in the biological irradiation-facility of the RIVM

    International Nuclear Information System (INIS)

    Bader, F.J.M.

    1990-02-01

    The RIVM biological irradiation facility (BBF) for the irradiation of biological samples and small animals is a self shielded device and can be safely operated in an existing laboratory environment. There are two 137 Cs sources (15TBq) in a bilateral geometry to give maximum dose uniformity. The easily accessible irradiation chamber is housed in a rotating lead shielding. The dosimetry of BBF was performed by the Dosimetry Section of the RIVM. Experiments were made to determine the absorbed dose in plastic tubes filled with water and the dose distribution over the tube-holder. Separate experiments were made to determine the absorbed dose during the rotation of the irradiation chamber and to check the irradiation timer. For the experiments LiF:Mg,Ti (TLD-100) extruded ribbons were used. The TLDs were calibrated in a collimated beam of 137 Cs gamma rays. The determination of the absorbed dose in water was based on a users biological irradiation set up. The TLDs were individually sealed in thin plastic foil and put in plastic tubes filled for 1/3 with water. The tubes were vertically placed in the tube-holder and placed in the centre of the irradiation chamber. The results show that the absorbed dose in water (determined on January 1, 1990) is equal to 0.97 Gy/timer-unit, with a total uncertainty of 7 percent (1σ). During the rotation of the irradiation chamber the absorbed dose (determined on January 1, 1990) is equal to 0.38 Gy, with a total uncertainty of 15 percent (1σ). The variation of the dose distribution was determined at 15 different measurement points distributed over the tube-holder. The dosis in the measurement point in the centre of the tube-holder was taken as reference value. The maximum observed deviation over the other 14 measurement points amounts to -16 percent of it. The BBF-timer was checked against a special timer. The results indicate that within a range from 2-11 'timer-units' no differences are present. (author). 6 refs.; 6 figs.; 3 fotos

  2. Investigation of a new LiF TLD individual dosimeter for measuring personal dose equivalent Hp(d) on different phantoms

    International Nuclear Information System (INIS)

    Jin, H.; Duftschmid, K.E.; Strachotinsky, C.

    1992-09-01

    The paper describes a new LiF TLD dosimeter designed for measuring personal dose equivalent, H p (d). Its energy and angular response have been studied in detail on a PMMA slab phantom using the conversion factors for TE slab phantom. According to the results obtained with four types of different conversion coefficients and phantoms, i.e. a PMMA slab, Water slab, ICRU sphere and Alderson Rando phantom, the conversion coefficients for the TE slab phantom are suitable for the calibration of TLD individual dosimeters on PMMA slab phantom. In the energy range 17 keV to 1250 KeV the energy response for H p (10) and H p (0.07) is energy independent within -20% to 8.4% for frontal irradiation. For angles within ±60 deg the new TLD dosimeters indicate H p (10) within 0 to 22.5% and H p (0.07) within -11.1% to 1.3%, respectively. (authors)

  3. Qualification study of LiF flight crystals for the objective crystal spectrometer on the SPECTRUM-X-GAMMA satellite

    DEFF Research Database (Denmark)

    Christensen, Finn Erland; Rasmussen, I.; Schnopper, Herbert W.

    1992-01-01

    The Objective Crystal Spectrometer (OXS) on the SPECTRUM-X-GAMMA satellite will carry these types of natural crystals LiF(220), Ge(111) and RAP(001). They will be used to study, among others, the H- and the He-like emission from the cosmically important elements Fe, S, Ar and O. More than 300 Li...

  4. Magnetic resonance of beta-active nuclei at double Larmor frequency in LiF polycrystals with dislocations

    International Nuclear Information System (INIS)

    Bulgakov, M.I.; Dzheparov, F.S.; Gul'ko, A.D.; Shestopal, V.E.; Stepanov, S.V.; Trostin, S.S.

    1989-01-01

    β-NMR-spectroscopy investigations of the resonance at double Larmor frequency of β-active nuclei 8 Li in LiF polycrystals are presented. The qualitative analysis of the dislocation influence on this resonance is developed. An important role of correlations in dislocation distributions as well as high responsivity of this resonance to quadrupole interactions are found. 13 refs.; 2 figs

  5. Extreme UV and X-ray scattering measurements from a rough LiF crystal surface characterized by electron micrography

    DEFF Research Database (Denmark)

    Alehyane; Arbaoui; Barchewitz

    1989-01-01

    XUV and X-ray scattering by a LiF crystal is measured. The angular distribution of the scattered radiation (ADSR) reveals characteristic features, side peaks or asymmetry. The surface of the sample is statistically characterized by a microdensitometer analysis of electron micrographs resolving th...

  6. Siim Nestor soovitab : Bell Orchestre. DJ Deep ja TRL. Akrobatik ja MC Mr.Lif. Black Dice / Siim Nestor

    Index Scriptorium Estoniae

    Nestor, Siim, 1974-

    2008-01-01

    Muusikaüritustest: Kanada post-rock ansambel Bell Orchestre12. sept. Tallinnas klubis Juuksur, DJ Deep 12. sept. Tallinna Linnahalli ruumides Plektrumi klubiööl (vt. www.plektrumfestival.ee), Akrobatik ja Mr.Lif 12. sept. Tartus klubis Illusion, New Yorgi kollektiiv Black Dice 17. sept. Tallinnas Von Krahlis

  7. Electronic structure, optical spectra and contact terms of the CoF64- cluster in LiF

    International Nuclear Information System (INIS)

    Albuquerque, E.L.; Maffeo, B.; Brandi, H.S.; Siqueira, M.L. de

    1975-01-01

    The electronic structure, the optical absorption bands and the magnetic hyperfine contact terms have been calculated for CoF 6 4- in LiF using the Multiple Scattering Xα Method. The results obtained are compared with experiment and once more indicated that this scheme is convenient to treat such complex problems

  8. Effects of specific and prolonged expression of zebrafish growth factors, Fgf2 and Lif in primordial germ cells in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Wong, Ten-Tsao, E-mail: wong20@purdue.edu [Department of Animal Sciences, Purdue University, 901 W. State Street, West Lafayette, IN 47907 (United States); Collodi, Paul [Department of Animal Sciences, Purdue University, 901 W. State Street, West Lafayette, IN 47907 (United States)

    2013-01-04

    Highlights: Black-Right-Pointing-Pointer We discovered that nanos3 3 Prime UTR prolonged PGC-specific protein expression up to 26 days. Black-Right-Pointing-Pointer Expression of Fgf2 in PGCs significantly increased PGC number at later developmental stages. Black-Right-Pointing-Pointer Expression of Lif in PGCs resulted in a significant disruption of PGC migration. Black-Right-Pointing-Pointer Lif illicited its effect on PGC migration through Lif receptor a. Black-Right-Pointing-Pointer Our approach could be used to achieve prolonged PGC-specific expression of other proteins. -- Abstract: Primordial germ cells (PGCs), specified early in development, proliferate and migrate to the developing gonad before sexual differentiation occurs in the embryo and eventually give rise to spermatogonia or oogonia. In this study, we discovered that nanos3 3 Prime UTR, a common method used to label PGCs, not only directed PGC-specific expression of DsRed but also prolonged this expression up to 26 days post fertilization (dpf) when DsRed-nanos3 3 Prime UTR hybrid mRNAs were introduced into 1- to 2-cell-stage embryos. As such, we employed this knowledge to express zebrafish leukemia inhibitory factor (Lif), basic fibroblast growth factor (Fgf2) and bone morphogenetic protein 4 (Bmp4) in the PGCs and evaluate their effects on PGC development in vivo for over a period of 3 weeks. The results show that expression of Fgf2 significantly increased PGC number at 14- and 21-dpf while Bmp4 resulted in severe ventralization and death of the embryos by 3 days. Expression of Lif resulted in a significant disruption of PGC migration. Mopholino knockdown experiments indicated that Lif illicited its effect on PGC migration through Lif receptor a (Lifra) but not Lifrb. The general approach described in this study could be used to achieve prolonged PGC-specific expression of other proteins to investigate their roles in germ cell and gonad development. The results also indicate that zebrafish PGCs

  9. Synchrotron radiation-induced contamination on LiF window: Characterization by Raman spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yadav, P. K., E-mail: praveenyadav@rrcat.gov.in [Material Research Laboratory, Indus Synchrotron Utilization Division (India); Swami, M. K. [Laser Biomedical Applications & Instrumentation Division, Raja Ramanna Centre for Advanced Technology, Indore-452013 (India)

    2016-05-23

    Characterization of synchrotron induced contamination on optical elements and their cleaning are serious issues in beam lines. We used Raman spectroscopy for characterization of synchrotron induced contamination layer on LiF window (used in high resolution vacuum ultra violet beam line). Three peaks at 1035 cm{sup −1} (corresponding to C-C sp{sup 3} vibrations), 1563 cm{sup −1} and 1375 cm{sup −1} (corresponding to G and D bands of carbon) are observed. By data fitting I(D)/I(G) ratio (0.84) and FWHM(G)=124 cm{sup −1} was obtained. Comparison with available literature indicates that the carbon might be present in the form of rings of hydrogenated amorphous carbon a-C:H (GLHC) with atomic hydrogen concentration about 15% with both sp{sup 2} and sp{sup 3} hybridization.

  10. Recovery of amplitude dependent internal friction in plastically deformed LiF single crystals

    International Nuclear Information System (INIS)

    Koshimizu, S.

    1977-01-01

    The internal friction due to is studied interactions between point defects and dislocations produced in pure LiF single crystais by plastic deformation. The recovery of amplitude dependent damping is investigated in these crystais in the low frequency range. The logarithmic decrement is measured as a function of strain amplitude at several different temperatures in the range 8C - 35C in order to observe thermal breakaway. The results were interpred according to the theory developed by Granato and Lucke. Systematic measurements are also been carried out to determine the logarithmic decrement as a function of time at different temperatures, after driving the specimens at high strains amplitudes, yelding the following results: I) there is a recovery of the amplitude dependent damping upon removal of the high strain excitations, and II) the Kinetic of the recovery follows initially a t sup(2/3) ageing law, changing to tsup(1/3) afterwards [pt

  11. Water stress assessment of cork oak leaves and maritime pine needles based on LIF spectra

    Science.gov (United States)

    Lavrov, A.; Utkin, A. B.; Marques da Silva, J.; Vilar, Rui; Santos, N. M.; Alves, B.

    2012-02-01

    The aim of the present work was to develop a method for the remote assessment of the impact of fire and drought stress on Mediterranean forest species such as the cork oak ( Quercus suber) and maritime pine ( Pinus pinaster). The proposed method is based on laser induced fluorescence (LIF): chlorophyll fluorescence is remotely excited by frequency-doubled YAG:Nd laser radiation pulses and collected and analyzed using a telescope and a gated high sensitivity spectrometer. The plant health criterion used is based on the I 685/ I 740 ratio value, calculated from the fluorescence spectra. The method was benchmarked by comparing the results achieved with those obtained by conventional, continuous excitation fluorometric method and water loss gravimetric measurements. The results obtained with both methods show a strong correlation between them and with the weight-loss measurements, showing that the proposed method is suitable for fire and drought impact assessment on these two species.

  12. MagLIF Pre-Heat Optimization on the PECOS Surrogacy Platform

    Science.gov (United States)

    Geissel, Matthias; Harvey-Thompson, A. J.; Ampleford, D.; Awe, T. J.; Bliss, D. E.; Glinsky, M. E.; Gomez, M. R.; Harding, E.; Hansen, S. B.; Jennings, C.; Kimmel, M. W.; Knapp, P. F.; Lewis, S. M.; Peterson, K.; Rochau, G. A.; Schollmeier, M.; Schwarz, J.; Shores, J. E.; Slutz, S. A.; Sinars, D. B.; Smith, I. C.; Speas, C. S.; Vesey, R. A.; Weis, M. R.; Porter, J. L.

    2017-10-01

    Sandia's MagLIF Program is using the PECOS target area as a platform to optimize the coupling of laser energy into the fuel. After developing laser pulse shapes that reduced SBS and improved energy deposition (presented last year), we will report on the effect on integrated experiments with Z. Despite encouraging results, questions remained about the equivalency of He, (PECOS studies), versus D2 (Z). Furthermore, simulations imply that the goal of at least 1 kJ in the fuel will require higher pressures, requiring a re-design of the gas delivery system. We will present recent results for backscatter measurements and energy deposition profiles in 60 psi and 90 psi deuterium fills and compare them to previously studied helium fills. Sandia National Labs is managed and operated by National Technology and Engineering Solutions of Sandia, LLC., a subsidiary of Honeywell International, Inc., for U.S. DoE/NNSA under contract DE-NA0003525.

  13. Production of excitons in grazing collisions of protons with LiF surfaces: An onion model

    Energy Technology Data Exchange (ETDEWEB)

    Miraglia, J. E.; Gravielle, M. S. [Instituto de Astronomia y Fisica del Espacio, Consejo Nacional de Investigaciones Cientificas y Tecnicas and Departamento de Fisica, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires, Casilla de Correo 67, Sucursal 28, (C1428EGA) Buenos Aires (Argentina)

    2011-12-15

    In this work we evaluate the production of excitons of a lithium fluoride crystal induced by proton impact in the intermediate and high energy regime (from 100 keV to 1 MeV). A simple model is proposed to account for the influence of the Coulomb grid of the target by dressing crystal ions to transform them in what we call onions. The excited states of these onions can be interpreted as excitons. Within this model, total cross section and stopping power are calculated by using the first Born and the continuum distorted-wave (CDW) eikonal initial-state (EIS) approximations. We found that between 7 and 30 excitons per incident proton are produced in grazing collisions with LiF surfaces, becoming a relevant mechanism of inelastic transitions.

  14. Improved sample preparation for CE-LIF analysis of plant N-glycans.

    Science.gov (United States)

    Nagels, Bieke; Santens, Francis; Weterings, Koen; Van Damme, Els J M; Callewaert, Nico

    2011-12-01

    In view of glycomics studies in plants, it is important to have sensitive tools that allow one to analyze and characterize the N-glycans present on plant proteins in different species. Earlier methods combined plant-based sample preparations with CE-LIF N-glycan analysis but suffered from background contaminations, often resulting in non-reproducible results. This publication describes a reproducible and sensitive protocol for the preparation and analysis of plant N-glycans, based on a combination of the 'in-gel release method' and N-glycan analysis on a multicapillary DNA sequencer. Our protocol makes it possible to analyze plant N-glycans starting from low amounts of plant material with highly reproducible results. The developed protocol was validated for different plant species and plant cells. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Measurement of Ambient Air Motion of D. I. Gasoline Spray by LIF-PIV

    Science.gov (United States)

    Yamakawa, Masahisa; Isshiki, Seiji; Yoshizaki, Takuo; Nishida, Keiya

    Ambient air velocity distributions in and around a D. I. gasoline spray were measured using a combination of LIF and PIV techniques. A rhodamine and water solution was injected into ambient air to disperse the fine fluorescent liquid particles used as tracers. A fuel spray was injected into the fluorescent tracer cloud and was illuminated by an Nd: YAG laser light sheet (532nm). The scattered light from the spray droplets and tracers was cut off by a high-pass filter (>560nm). As the fluorescence (>600nm) was transmitted through the high-pass filter, the tracer images were captured using a CCD camera and the ambient air velocity distribution could be obtained by PIV based on the images. This technique was applied to a D. I. gasoline spray. The ambient air flowed up around the spray and entered into the tail of the spray. Furthermore, the relative velocity between the spray and ambient air was investigated.

  16. Photoelectron emission from LiF surfaces by ultrashort electromagnetic pulses

    International Nuclear Information System (INIS)

    Acuna, M. A.; Gravielle, M. S.

    2011-01-01

    Energy- and angle-resolved electron emission spectra produced by incidence of ultrashort electromagnetic pulses on a LiF(001) surface are studied by employing a distorted-wave method named the crystal surface-Volkov (CSV) approximation. The theory makes use of the Volkov phase to describe the action of the external electric field on the emitted electron, while the electron-surface interaction is represented within the tight-binding model. The CSV approach is applied to investigate the effects introduced by the crystal lattice when the electric field is oriented parallel to the surface plane. These effects are essentially governed by the vector potential of the external field, while the influence of the crystal orientation was found to be negligible.

  17. Thermal neutron detection using a silicon pad detector and {sup 6}LiF removable converters

    Energy Technology Data Exchange (ETDEWEB)

    Barbagallo, Massimo [Istituto Nazionale di Fisica Nucleare, Sezione di Bari (Italy); Cosentino, Luigi; Marchetta, Carmelo; Pappalardo, Alfio; Scire, Carlotta; Scire, Sergio; Schillaci, Maria; Vecchio, Gianfranco; Finocchiaro, Paolo [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, Catania (Italy); Forcina, Vittorio; Peerani, Paolo [European Commission, Joint Research Centre, Institute of Transuranium Elements, Ispra (Italy); Vaccaro, Stefano [European Commission, Directorate-General for Energy (Luxembourg)

    2013-03-15

    A semiconductor detector coupled with a neutron converter is a good candidate for neutron detection, especially for its compactness and reliability if compared with other devices, such as {sup 3}He tubes, even though its intrinsic efficiency is rather lower. In this paper we show a neutron detector design consisting of a 3 cm Multiplication-Sign 3 cm silicon pad detector coupled with one or two external {sup 6}LiF layers, enriched in {sup 6}Li at 95%, placed in contact with the Si active surfaces. This prototype, first characterized and tested at INFN Laboratori Nazionali del Sud and then at JRC Ispra, was successfully shown to detect thermal neutrons with the expected efficiency and an outstanding gamma rejection capability.

  18. Multi-Objective data analysis using Bayesian Inference for MagLIF experiments

    Science.gov (United States)

    Knapp, Patrick; Glinksy, Michael; Evans, Matthew; Gom, Matth; Han, Stephanie; Harding, Eric; Slutz, Steve; Hahn, Kelly; Harvey-Thompson, Adam; Geissel, Matthias; Ampleford, David; Jennings, Christopher; Schmit, Paul; Smith, Ian; Schwarz, Jens; Peterson, Kyle; Jones, Brent; Rochau, Gregory; Sinars, Daniel

    2017-10-01

    The MagLIF concept has recently demonstrated Gbar pressures and confinement of charged fusion products at stagnation. We present a new analysis methodology that allows for integration of multiple diagnostics including nuclear, x-ray imaging, and x-ray power to determine the temperature, pressure, liner areal density, and mix fraction. A simplified hot-spot model is used with a Bayesian inference network to determine the most probable model parameters that describe the observations while simultaneously revealing the principal uncertainties in the analysis. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology and Engineering Solutions of Sandia, LLC., a wholly owned subsidiary of Honeywell International, Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA-0003525.

  19. Food irradiation

    International Nuclear Information System (INIS)

    Soothill, R.

    1987-01-01

    The issue of food irradiation has become important in Australia and overseas. This article discusses the results of the Australian Consumers' Association's (ACA) Inquiry into food irradiation, commissioned by the Federal Government. Issues discussed include: what is food irradiation; why irradiate food; how much food is consumer rights; and national regulations

  20. Food irradiation

    International Nuclear Information System (INIS)

    Lindqvist, H.

    1996-01-01

    This paper is a review of food irradiation and lists plants for food irradiation in the world. Possible applications for irradiation are discussed, and changes induced in food from radiation, nutritional as well as organoleptic, are reviewed. Possible toxicological risks with irradiated food and risks from alternative methods for treatment are also brought up. Ways to analyze weather food has been irradiated or not are presented. 8 refs

  1. Magnetism reflectometer study shows LiF layers improve efficiency in spin valve devices

    Energy Technology Data Exchange (ETDEWEB)

    Bardoel, Agatha A [ORNL; Lauter, Valeria [ORNL; Szulczewski, Greg J [ORNL

    2012-01-01

    New, more efficient materials for spin valves - a device used in magnetic sensors, random access memories, and hard disk drives - may be on the way based on research using the magnetism reflectometer at Oak Ridge National Laboratory (ORNL). Spin valve devices work by means of two or more conducting magnetic material layers that alternate their electrical resistance depending on the layers alignment. Giant magnetoresistance is a quantum mechanical effect first observed in thin film structures about 20 years ago. The effect is observed as a significant change in electrical resistance, depending on whether the magnetization of adjacent ferromagnetic layers is in a parallel or an antiparallel magnetic alignment. 'What we are doing here is developing new materials. The search for new materials suitable for injecting and transferring carriers with a preferential spin orientation is most important for the development of spintronics,' said Valeria Lauter, lead instrument scientist on the magnetism reflectometer at the Spallation Neutron Source (SNS), who collaborated on the experiment. The researchers discovered that the conductivity of such materials is improved when an organic polymer semiconductor layer is placed between the magnetic materials. Organic semiconductors are now the material of choice for future spin valve devices because they preserve spin coherence over longer times and distances than conventional semiconductors. While research into spin valves has been ongoing, research into organic semiconductors is recent. Previous research has shown that a 'conductivity mismatch' exists in spin valve systems in which ferromagnetic metal electrodes interface with such organic semiconductors as Alq3 ({pi}-conjugated molecule tris(8-hydroxy-quinoline) aluminium). This mismatch limits the efficient injection of the electrons from the electrodes at the interface with the semiconductor material. However, lithium fluoride (LiF), commonly used in light

  2. Validation and dosimetric evaluation employing the techniques of TL and OSL of thermoluminescent materials for application in the dosimetry of clinical beams of electrons used in total irradiation of the skin - TSI

    International Nuclear Information System (INIS)

    Almeida, Shirlane Barbosa de

    2017-01-01

    In vivo dosimetry has become an important role for the treatment of total skin irradiation within a rigorous quality assurance program that should be an integral part of the radiotherapy departments. TSI dosimetry is difficult because of the complexity of the treatment in assessing dose uniformity and measuring the dose absorbed at shallow depths throughout the skin surface extent, resulting in a wide variation in dose distribution. The TLDs have proven to be very useful for the distribution and verification of the dose prescribed for the patient as the dose may differ from place to place due to patient body geometry, overlapping of structures and asymmetries of the radiation field. The use of TLDs in vivo can identify variations in the prescribed dose because its measurement accuracy and great precision. Several types of dosimeters have been used in the radiotherapy sectors, the most commonly used are Lithium Fluride (TLD-100), where it obtains a long history in this type of application. New dosimetric materials have gained great importance in the dosimetry of clinical electron beams, such as Dysprosium-doped Calcium Sulphate (TL) and Carbon doped (OSL) based Aluminum Oxide, This work evaluates the performance of the respective thermoluminescent dosimeters and the optically stimulated luminescence in the dosimetry of clinical electron beams used in total irradiation of the skin. (author)

  3. Food irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Gruenewald, T

    1985-01-01

    Food irradiation has become a matter of topical interest also in the Federal Republic of Germany following applications for exemptions concerning irradiation tests of spices. After risks to human health by irradiation doses up to a level sufficient for product pasteurization were excluded, irradiation now offers a method suitable primarily for the disinfestation of fruit and decontamination of frozen and dried food. Codex Alimentarius standards which refer also to supervision and dosimetry have been established; they should be adopted as national law. However, in the majority of cases where individual countries including EC member-countries so far permitted food irradiation, these standards were not yet used. Approved irradiation technique for industrial use is available. Several industrial food irradiation plants, partly working also on a contractual basis, are already in operation in various countries. Consumer response still is largely unknown; since irradiated food is labelled, consumption of irradiated food will be decided upon by consumers.

  4. Integrated readout of organic scintillator and ZnS:Ag/6LiF for segmented antineutrino detectors

    International Nuclear Information System (INIS)

    Kiff, Scott D.; Reyna, David; Monahan, James; Bowden, Nathaniel S.

    2010-01-01

    Antineutrino detection using inverse beta decay conversion has demonstrated the capability to measure nuclear reactor power and fissile material content for nuclear safeguards. Current efforts focus on aboveground deployment scenarios, for which highly efficient capture and identification of neutrons is needed to measure the anticipated antineutrino event rates in an elevated background environment. In this submission, we report on initial characterization of a new scintillation-based segmented design that uses layers of ZnS:Ag/ 6 LiF and an integrated readout technique to capture and identify neutrons created in the inverse beta decay reaction. Laboratory studies with multiple organic scintillator and ZnS:Ag/ 6 LiF configurations reliably identify 6 Li neutron captures in 60 cm-long segments using pulse shape discrimination.

  5. A new approach for cloning hLIF cDNA from genomic DNA isolated from the oral mucous membrane.

    Science.gov (United States)

    Cui, Y H; Zhu, G Q; Chen, Q J; Wang, Y F; Yang, M M; Song, Y X; Wang, J G; Cao, B Y

    2011-11-25

    Complementary DNA (cDNA) is valuable for investigating protein structure and function in the study of life science, but it is difficult to obtain by traditional reverse transcription. We employed a novel strategy to clone human leukemia inhibitory factor (hLIF) gene cDNA from genomic DNA, which was directly isolated from the mucous membrane of mouth. The hLIF sequence, which is 609 bp long and is composed of three exons, can be acquired within a few hours by amplifying each exon and splicing all of them using overlap-PCR. This new approach developed is simple, time- and cost-effective, without RNA preparation or cDNA synthesis, and is not limited to the specific tissues for a particular gene and the expression level of the gene.

  6. Specific heat measurements of TiB2 and 6LiF from 0.5 to 30 K

    International Nuclear Information System (INIS)

    Lang, Brian E.; Donaldson, Marcus H.; Woodfield, Brian F.; Burger, Arnold; Roy, Utupal N.; Lamberti, Vincent; Bell, Zane W.

    2005-01-01

    The specific heats of TiB 2 and 6 LiF have been measured from 0.5 to 30 K as part of a larger project in the construction of a neutron spectrometer. For this application, the measured specific heats were used to extrapolate the specific heats down to 0.1 K with lattice, electronic, and Schottky equations for the respective samples. The resultant specific heat values at 0.1 K for TiB 2 and 6 LiF are 4.08 x 10 -4 ± 0.27 x 10 -4 J/K/mol and 9.19 x 10 -9 ± 0.15 x 10 -9 J/K/mol, respectively

  7. Ab-initio perturbed-cluster study of carbon monoxide adsorption at a stepped LiF(001) surface

    Science.gov (United States)

    Pisani, C.; Corà, F.; Orlando, R.; Nada, R.

    1993-02-01

    The perturbed-cluster ab-initio Hartree-Fock approach to the study of local defects in crystals [J. Chem. Phys. 92(1990)7448] is applied to the study of CO adsorption at a stepped LiF(001) surface. The step is simulated by a tablet of four ions superimposed on an infinite LiF(001) monolayer. The geometry of the step is first optimized, and corresponds to an important relaxation of cations and anions of the tablet inwards and outwards, respectively. The equilibrium configuration, adsorption energy and vibrational frequency of CO at a corner of the tablet occupied by a lithium cation are calculated. With respect to adsorption at a perfect (100) face, there is a large increase in interaction energy, especially when adsorption occurs via the oxygen atom. This difference is essentially related to modifications of the electrostatic field experienced by the adsorbed molecule.

  8. Determination of the structure factors of a LiF powder sample by the energy dispersive x-ray diffraction

    International Nuclear Information System (INIS)

    Uno, R.; Ahtee, A.; Paakkari, T.

    1977-01-01

    The structure factors of a LiF powder sample were determined by energy dispersive x-ray diffraction in the range 9 to 25 keV, with the use of a Si(Li) solid state detector, following the method applied on GaP. Since the absorption coefficient of LiF is small at high energy, a fraction of the incident x-rays penetrates through the sample and does not contribute to the diffraction. This effect was taken into account in the determination of the structure factors. Then the structure factors generally agree, within the limit of 5 % error, with those obtained by the usual angle dispersive method, if the penetrated part of the incident beam is less than 40 %. (author)

  9. Comparison of LiF and FeSO4 dosimetry with cavity theory for high-energy electrons

    International Nuclear Information System (INIS)

    Fregene, A.O.

    1976-01-01

    Using FeSO 4 dosimetry in a comparative study, the response of LiF dosimeter rods 1 mm in diameter by 6 mm in length to electron beams of initial energies in the range 5 to 39 MeV was investigated. The electron beam cavity theories of T. E. Burlin, R. J. Shelling, and B. Owen (1969), P. R. Almond and K. McCray (1970), and L. H. Bragg-Gray (1937) were employed in the estimation of absorbed doses. The LiF dosimeter was found energy independent over the range of electron energies covered. Bragg-Gray's and Almond's electron beam theories confirm this finding within 2 percent. The overall experimental error in the work is within 2 percent. Burlin's electron beam theory gave values that were considerably out, especially at the lower end of the range of energy covered

  10. LIF study of N2(A3+u, v=0-10) vibrational kinetics under nitrogen streamer conditions

    Czech Academy of Sciences Publication Activity Database

    Šimek, Milan; Ambrico, P. F.; Prukner, Václav

    2015-01-01

    Roč. 48, č. 26 (2015), s. 265202-265202 ISSN 0022-3727 R&D Projects: GA ČR(CZ) GAP205/12/1709 Institutional support: RVO:61389021 Keywords : nitrogen metastable * streamer * optical diagnostics * laser-induced fluorescence * LIF Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 2.772, year: 2015 http://dx.doi.org/10.1088/0022-3727/48/26/265202

  11. Effect of ion velocity on creation of point defects halos of latent tracks in LiF

    Czech Academy of Sciences Publication Activity Database

    Volkov, A.E.; Schwartz, K.; Medvedev, Nikita; Trautmann, C.

    2017-01-01

    Roč. 407, Sep (2017), s. 80-85 ISSN 0168-583X R&D Projects: GA MŠk LG15013; GA MŠk(CZ) LM2015083 Institutional support: RVO:68378271 Keywords : swift heavy ion * electronic stopping * track * LiF * color centers * defect halo Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: Fluids and plasma physics (including surface physics) Impact factor: 1.109, year: 2016

  12. Study of the fluorescence blinking behavior of single F2 color centers in LiF crystal

    International Nuclear Information System (INIS)

    Boichenko, S V; Koenig, K; Zilov, S A; Dresvianskiy, V P; Rakevich, A L; Kuznetsov, A V; Bartul, A V; Martynovich, E F; Voitovich, A P

    2014-01-01

    Using confocal fluorescence microscopy technique, we observed experimentally the luminescence of single F 2 color centers in LiF crystal. It is disclosed that the fluorescence shows blinking behavior. It is shown that this phenomenon is caused by the F 2 center reorientation occurring during the experiment. The ratio of luminescence intensities of differently oriented centers is assessed theoretically for two different experiment configurations. The calculated ratios are in fine agreement with experimental result

  13. Personnel photon dosimeter on the base of TLD sup n sup a sup t LiF

    CERN Document Server

    Kaskanov, G Y

    2003-01-01

    A personnel photon dosemeter on the basis of thermoluminescence detectors (TLD) sup n sup a sup t LiF is described. Experimental responses of the dosemeters in the unit of individual equivalent dose H sub p (10) for energy of photons 59.5, 120, 662, and 1250 keV are presented. It is shown that the dosemeter allows one to measure H sub p (10) with admissible uncertainty in the energy range from 60 to 1250 keV.

  14. Statistical differences and systematic effect on measurement procedure in thermoluminescent dosimetry of the Iodine-125 brachytherapy seed

    International Nuclear Information System (INIS)

    Zeituni, Carlos A.; Moura, Eduardo S.; Rostelato, Maria Elisa C.M.; Manzoli, Jose E.; Moura, Joao Augusto; Feher, Anselmo; Karam, Dib

    2009-01-01

    In order to provide the dosimetry for Iodine-125 seed production in Brazil, Harshaw thermoluminescent dosimeters (TLD-100) will be used. Even if measurements with TLD-100 of the same batch of fabrication are performed, the response will not be the same. As a consequence, they must be measured one by one. These dosimeters are LiF type with a micro-cube (1 mm x 1 mm x 1 mm) shape. Irradiations were performed using Iodine-125 seeds to guarantee the same absorbed dose of 5 Gy in each dosimeter. It has been used a Solid Water Phantom with three concentrically circle with 20 mm, 50 mm and 70 mm diameters. The angle of positions used was 0 deg, 30 deg, 60 deg and 90 deg. Of course there are 2 positions in 0 deg and 90 deg and 4 positions in 30 deg and 60 deg. These complete procedures were carried out five times in order to compare the data and minimize the systematic error. The iodine-125 seed used in the experiment was take off in each measure and put again turning his position 180 deg to guarantee the systematic error was minimized. This paper presents also a little discussion about the statistical difference in the measurement and the calculation procedure to determine the systematic error in these measurements. (author)

  15. Statistical differences and systematic effect on measurement procedure in thermoluminescent dosimetry of the Iodine-125 brachytherapy seed

    Energy Technology Data Exchange (ETDEWEB)

    Zeituni, Carlos A.; Moura, Eduardo S.; Rostelato, Maria Elisa C.M.; Manzoli, Jose E.; Moura, Joao Augusto; Feher, Anselmo, E-mail: czeituni@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP) Sao Paulo, SP (Brazil); Karam, Dib [Universidade de Sao Paulo (USP Leste), Sao Paulo, SP (Brazil). Escola de Artes, Ciencias e Humanidades

    2009-07-01

    In order to provide the dosimetry for Iodine-125 seed production in Brazil, Harshaw thermoluminescent dosimeters (TLD-100) will be used. Even if measurements with TLD-100 of the same batch of fabrication are performed, the response will not be the same. As a consequence, they must be measured one by one. These dosimeters are LiF type with a micro-cube (1 mm x 1 mm x 1 mm) shape. Irradiations were performed using Iodine-125 seeds to guarantee the same absorbed dose of 5 Gy in each dosimeter. It has been used a Solid Water Phantom with three concentrically circle with 20 mm, 50 mm and 70 mm diameters. The angle of positions used was 0 deg, 30 deg, 60 deg and 90 deg. Of course there are 2 positions in 0 deg and 90 deg and 4 positions in 30 deg and 60 deg. These complete procedures were carried out five times in order to compare the data and minimize the systematic error. The iodine-125 seed used in the experiment was take off in each measure and put again turning his position 180 deg to guarantee the systematic error was minimized. This paper presents also a little discussion about the statistical difference in the measurement and the calculation procedure to determine the systematic error in these measurements. (author)

  16. Food irradiation

    International Nuclear Information System (INIS)

    Sato, Tomotaro; Aoki, Shohei

    1976-01-01

    Definition and significance of food irradiation were described. The details of its development and present state were also described. The effect of the irradiation on Irish potatoes, onions, wiener sausages, kamaboko (boiled fish-paste), and mandarin oranges was evaluated; and healthiness of food irradiation was discussed. Studies of the irradiation equipment for Irish potatoes in a large-sized container, and the silo-typed irradiation equipment for rice and wheat were mentioned. Shihoro RI center in Hokkaido which was put to practical use for the irradiation of Irish potatoes was introduced. The state of permission of food irradiation in foreign countries in 1975 was introduced. As a view of the food irradiation in the future, its utilization for the prevention of epidemics due to imported foods was mentioned. (Serizawa, K.)

  17. The influence of ion hydration on nucleation and growth of LiF crystals in aqueous solution.

    Science.gov (United States)

    Lanaro, G; Patey, G N

    2018-01-14

    Molecular dynamics (MD) simulations are employed to investigate crystal nucleation and growth in oversaturated aqueous LiF solutions. Results obtained for a range of temperatures provide evidence that the rate of crystal growth is determined by a substantial energy barrier (∼49 kJ mol -1 ) related to the loss of water from the ion hydration shells. Employing direct MD simulations, we do not observe spontaneous nucleation of LiF crystals at 300 K, but nucleation is easily observable in NVT simulations at 500 K. This contrasts with the NaCl case, where crystal nucleation is directly observed in similar simulations at 300 K. Based on these observations, together with a detailed analysis of ion clustering in metastable LiF solutions, we argue that the ion dehydration barrier also plays a key role in crystal nucleation. The hydration of the relatively small Li + and F - ions strongly influences the probability of forming large, crystal-like ion clusters, which are a necessary precursor to nucleation. This important factor is not accounted for in classical nucleation theory.

  18. Density functional theory of electron transfer beyond the Born-Oppenheimer approximation: Case study of LiF

    Science.gov (United States)

    Li, Chen; Requist, Ryan; Gross, E. K. U.

    2018-02-01

    We perform model calculations for a stretched LiF molecule, demonstrating that nonadiabatic charge transfer effects can be accurately and seamlessly described within a density functional framework. In alkali halides like LiF, there is an abrupt change in the ground state electronic distribution due to an electron transfer at a critical bond length R = Rc, where an avoided crossing of the lowest adiabatic potential energy surfaces calls the validity of the Born-Oppenheimer approximation into doubt. Modeling the R-dependent electronic structure of LiF within a two-site Hubbard model, we find that nonadiabatic electron-nuclear coupling produces a sizable elongation of the critical Rc by 0.5 bohr. This effect is very accurately captured by a simple and rigorously derived correction, with an M-1 prefactor, to the exchange-correlation potential in density functional theory, M = reduced nuclear mass. Since this nonadiabatic term depends on gradients of the nuclear wave function and conditional electronic density, ∇Rχ(R) and ∇Rn(r, R), it couples the Kohn-Sham equations at neighboring R points. Motivated by an observed localization of nonadiabatic effects in nuclear configuration space, we propose a local conditional density approximation—an approximation that reduces the search for nonadiabatic density functionals to the search for a single function y(n).

  19. Colour centres in LiF for measurement of abssorbed doses up to 100 MGy

    International Nuclear Information System (INIS)

    McLaughlin, W.L.

    1996-01-01

    Radiation damage studies on electronic components, polymers, composites, ceramics, metals and insulating materials exposed to very large doses of ionising photons and particles (i.e. electrons, protons, and neutrons) require reproducible and accurate passive dosimetry. Absorbed doses in the range 10 2 -2 x 10 6 Gy have previously been measured with optical quality, undoped LiF by spectrophotometry of radiation-induced absorption bands of stable colour centres. These include the relatively stable F centre (247 nm), M centre (443 nm), R 1 centre (315 nm), R 2 centre (374 nm), and N 2 centre (547 nm). It is now possible to extend this range to 10 8 Gy by spectrophotometry of the N 1 centre (517 nm) and an 'X' centre (785 nm). These dosemeters can be used from cryogenic (4 K) to relatively high radiation temperatures (up to 500 K). The radiation-induced coloration can be bleached for re-use of the dosemeters by a two hour thermal annealing treatment at 830 K. (Author)

  20. Diagnosing the Stagnation Conditions of MagLIF Implosions Using Co and Kr dopants

    Science.gov (United States)

    Harding, E. C.; Hansen, S. B.; Harvey-Thompson, A. J.; Weis, M. R.; Hahn, K. D.; Gomez, M. R.; Knapp, P. F.; Slutz, S. A.; Geissel, M.; Ampleford, D. J.; Jennings, C. A.; Peterson, K.; Rochau, G. A.; Doron, R.; Stambulchik, E.; Nedostup, O.; Maron, Y.; Golovkin, I.

    2017-10-01

    Recent experiments on the Z-machine tested several new diagnostic techniques for investigating the stagnation conditions and the origins of the mix present in a Magnetized Liner Inertial Fusion (MagLIF) target. For the first time we have collected K-shell spectra from a low-concentration, Kr dopant placed in the gaseous D2 fuel. In addition, thin Co coatings were strategically applied to three different internal surfaces of the target in order to assess which surfaces actively contribute to the contamination of the fuel. Both imaging spectroscopy and narrow-band crystal imaging were used to identify the location of He-like Co ions. The Te and ne of the Co is inferred by fitting the He-alpha lines and the near-by Li-like satellites. The experimental measurements and the challenges associated with the analysis will be discussed. Sandia Natl Lab is a multi-mission laboratory managed and operated by National Technology and Engineering Solutions of Sandia, LLC., a wholly owned subsidiary of Honeywell International, Inc., for the U.S. DOE NNSA under contract DE-NA-0003525.

  1. Time resolved LIF measurements for the study of NO removal: influence of H2O

    International Nuclear Information System (INIS)

    Fresnet, F.; Baravian, G.; Magne, L.; Pasquiers, S.; Postel, C.; Puech, V.; Rousseau, A.

    2001-01-01

    We have developed a time-resolved laser-induced fluorescence (LIF) diagnostic of the NO-removal in a pre-ionized homogeneous discharge, i.e. without density nor temperature gradients, using the photo-triggering technique. This technique allows to measure specie densities in the temporal post-discharge after one homogeneous pulsed excitation, so that experimental results can be more confidently compared to predictions of a 0D-model, i.e. a model which have a spatially homogeneous kinetic description of the cleaning process. This model is fully self-consistent and describe both kinetics during the discharge and the post-discharge. We first reported the influence of electrical parameters (energy and reduced electric field) on the NO removal efficiency in the N 2 /NO mixture. Then, the influence of hydrocarbon (C 2 H 4 ) addition was determined. We showed that dissociation of NO through collision with the metastable state N 2 (a '1 Σ u - ) play the main part in the NO-removal process in homogeneously excited N 2 /NO mixture, and, that a de-excitation process of N 2 (a '1 Σ u - ) by C 2 H 4 explains that the NO-removal efficiency decreases when ethene is added to the mixture. Estimation for the rate coefficient value of this reaction, closed to the known value for methane, was also deduced from our results. In this study, the influence of water is investigated on the NO removal efficiency

  2. Diffractive scattering of H atoms from the (001) surface of LiF at 78 K

    International Nuclear Information System (INIS)

    Caracciolo, G.; Iannotta, S.; Scoles, G.; Valbusa, U.

    1980-01-01

    We have built an apparatus for the measurement of high resolution diffractive scattering of hydrogen atoms from crystal surfaces. The apparatus comprises a hydrogen atom beam source, a hexapolar magnetic field velocity selector, a variable temperature UHV crystal manipulator, and a rotatable bolometer detector. The diffraction pattern of a beam of hydrogen atoms scattered by a (001) LiF surface at 78 K has been obtained for different angles of incidence and different orientations of the crystal. The Debye--Waller factor has been measured leading to a surface Debye temperature theta/sub S/=550 +- 38 K. The corrugated-hard-wall-with-a-well model of Garibaldi et al. [Surf. Sci. 48, 649 (1975)] has been used for the interpretation of the intensities of the diffracted peaks. By means of a best fit procedure we obtain a main ''corrugation'' parameter xi 0 =0.095 A. By comparison of the data with the theory of Cabrera et al. [Surf. Sci. 19, 70 (1967] at the first order, the strength parameters of a periodic Morse potential have been determined

  3. Deformation mechanism in LiF single crystals at 1.7 to 330 K

    International Nuclear Information System (INIS)

    Niaz, S.; Butt, M.Z.

    1999-01-01

    The experimental data appertaining to the influence of temperature on the critical resolved shear stress (CRSS) of LiF ionic single crystals containing 10/sup -3/ wt% of divalent metal impurities in the range 1.7 to 330 K have been analyzed within the framework of the kink-pair nucleation (KPN) model of plastic flow in crystalline materials. The CRSS-T data when plotted in log-linear coordinates exhibit three distinct regions represented by straight lines of different slopes. In the temperature range 1.7 to 90 K, the CRSS 6 determined primarily by the stress-assisted thermally-activated escape of screw dislocations trapped in the Peierls troughs. At temperatures between 90 and 260 K, the rate process of plastic deformation is unpinning of edge-dislocation segments from short was rows of randomly dispersed point defects, e.g. residual metal impurities atoms, divalent metal ion-vacancy dipoles, induced defects formed during the pre-yield stage etc. 4. However, at higher temperatures up to 330 K, the CRSS decreases rapidly with rise in temperature, probably due to the mobility of the point defects referred to, and the KPN model becomes inapplicable. (author)

  4. 2D temperature field measurement in a direct-injection engine using LIF technology

    Science.gov (United States)

    Liu, Yongfeng; Tian, Hongsen; Yang, Jianwei; Sun, Jianmin; Zhu, Aihua

    2011-12-01

    A new multi-spectral detection strategy for temperature laser- induced- fluorescence (LIF) 2-D imaging measurements is reported for high pressure flames in high-speed diesel engine. Schematic of the experimental set-up is outlined and the experimental data on the diesel engine is summarized. Experiment injection system is a third generation Bosch high-pressure common rail featuring a maximum pressure of 160MPa. The injector is equipped with a six-hole nozzle, where each hole has a diameter of 0.124 mm. and slightly offset to the center of the cylinder axis to allow a better cooling of the narrow bridge between the exhaust valves. The measurement system includes a blower, which supplied the intake flow rate, and a prototype single-valve direct injection diesel engine head modified to lay down the swirled-type injector. 14-bit digital CCD cameras are employed to achieve a greater level of accuracy in comparison to the results of previous measurements. The temperature field spatial distributions in the cylinder for different crank angle degrees are carried out in a single direct-injection diesel engine.

  5. Air-water flow measurement for ERVC conditions by LIF/PIV

    International Nuclear Information System (INIS)

    Yoon, Jong Woong; Jeong, Yong Hoon

    2016-01-01

    Critical heat flux (CHF) of the external reactor vessel wall is a safety limit that indicate the integrity of the reactor vessel during the situation. Many research conducted CHF experiments in the IVR-ERVC conditions. However, the flow velocity field which is an important factor in the CHF mechanism were not studied enough in the IVR-ERVC situations. In this study, flow measurements including velocity vector field and the liquid velocity in the IVR-ERVC conditions were studied. The air-water two phase flow loop simulating IVRERVC conditions was set up and liquid velocity field was measured by LIF/PIV technique in this study. The experiment was conducted with and without air injection conditions. For the air-water flow experiment, liquid velocity at the outside of two phase boundary layer became higher and the two phase boundary layer thickness became smaller when the mass flux increases. The velocity data obtained in this study are expected to improve the CHF correlation in the IVR-ERVC situations.

  6. PIV and LIF study of flow and thermal fields of twine plumes in water

    Science.gov (United States)

    Broučková, Zuzana; Trávníček, Zdeněk

    Flow and thermal fields of a pair of plane plumes in water are investigated by means of PIV and LIF experiments. The plumes are generated from thermal line sources, which are made out of electrically heated cylinders with a diameter of D = 1.21 mm. A cylinder-to-cylinder distance was 17.9 D. Either continuous or pulsating heating were used with the same heating input power. Because the cylinder-to-cylinder distance is moderately small, deflections of plumes from a vertical direction occur and the plumes are inclined together. This behavior is caused by a confined entrainment from a space between the both plumes. For a continuous heating, low frequency oscillations were identified and the natural frequency was evaluated as 0.5 Hz. Based on this finding, pulsating heating was used at the subharmonic frequency of 0.25 Hz. The maximum time-mean velocity magnitude at the continuous and pulsating heating were commensurable, approximately 0.007 m/s. On the other hand, pulsating heating achieves by 36 % higher velocity peaks. A very strong velocity oscillations were generated by pulsating heating at the distance approximately 8.3 D above the cylinders, where the velocity maxima oscillate along the time-mean value of 0.0057 m/s from -30% to +70 %. Temperature fields reasonably agree with this findings, despite a relatively fast equalization of the temperature field was concluded. The results demonstrate enhancement effects of pulsations in flow/thermal fields.

  7. Air-water flow measurement for ERVC conditions by LIF/PIV

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jong Woong; Jeong, Yong Hoon [KAIST, Daejeon (Korea, Republic of)

    2016-05-15

    Critical heat flux (CHF) of the external reactor vessel wall is a safety limit that indicate the integrity of the reactor vessel during the situation. Many research conducted CHF experiments in the IVR-ERVC conditions. However, the flow velocity field which is an important factor in the CHF mechanism were not studied enough in the IVR-ERVC situations. In this study, flow measurements including velocity vector field and the liquid velocity in the IVR-ERVC conditions were studied. The air-water two phase flow loop simulating IVRERVC conditions was set up and liquid velocity field was measured by LIF/PIV technique in this study. The experiment was conducted with and without air injection conditions. For the air-water flow experiment, liquid velocity at the outside of two phase boundary layer became higher and the two phase boundary layer thickness became smaller when the mass flux increases. The velocity data obtained in this study are expected to improve the CHF correlation in the IVR-ERVC situations.

  8. Gamma irradiator

    International Nuclear Information System (INIS)

    Simonet, G.

    1986-09-01

    Fiability of devices set around reactors depends on material resistance under irradiation noticeably joints, insulators, which belongs to composition of technical, safety or physical incasurement devices. The irradiated fuel elements, during their desactivation in a pool, are an interesting gamma irradiation device to simulate damages created in a nuclear environment. The existing facility at Osiris allows to generate an homogeneous rate dose in an important volume. The control of the element distances to irradiation box allows to control this dose rate [fr

  9. Food irradiation

    International Nuclear Information System (INIS)

    Anon.

    1985-01-01

    The article explains what radiation does to food to preserve it. Food irradiation is of economic importance to Canada because Atomic Energy of Canada Limited is the leading world supplier of industrial irradiators. Progress is being made towards changing regulations which have restricted the irradiation of food in the United States and Canada. Examples are given of applications in other countries. Opposition to food irradiation by antinuclear groups is addressed

  10. Food irradiation

    International Nuclear Information System (INIS)

    Beyers, M.

    1977-01-01

    The objectives of food irradiation are outlined. The interaction of irradiation with matter is then discussed with special reference to the major constituents of foods. The application of chemical analysis in the evaluation of the wholesomeness of irradiated foods is summarized [af

  11. Effective energies and exposure determinations of two different energy X-ray beams incident on a personnel monitor

    International Nuclear Information System (INIS)

    Okuno, E.; Cruz, M.T. da

    1984-01-01

    The effective energy of one X or gamma ray beam can be determined by means of two thermoluminescent (TL) dosemeters mounted between suitable filters. However, it has been observed that personnel monitors exposed to two different energy ionizing radiations provide different effective energies depeding on the type of TL phosphor used. This fact could be a powerful tool for identifying exposures to radiation with quite different effective energies which are very common in practice. Two types of TL dosemeters were used : pellets of cold pressed natural fluoride and NaCl developed in our own laboratory, and LiF, TLD-100 from Harshaw Chemical Co.. Experimental results obtained with these combined dosemeters after irradiation with different sets of exposures and energy values of ionizing radiations are also presented. (Author) [pt

  12. N-Myc regulates expression of pluripotency genes in neuroblastoma including lif, klf2, klf4, and lin28b.

    Directory of Open Access Journals (Sweden)

    Rebecca Cotterman

    2009-06-01

    Full Text Available myc genes are best known for causing tumors when overexpressed, but recent studies suggest endogenous myc regulates pluripotency and self-renewal of stem cells. For example, N-myc is associated with a number of tumors including neuroblastoma, but also plays a central role in the function of normal neural stem and precursor cells (NSC. Both c- and N-myc also enhance the production of induced pluripotent stem cells (iPSC and are linked to neural tumor stem cells. The mechanisms by which myc regulates normal and neoplastic stem-related functions remain largely open questions. Here from a global, unbiased search for N-Myc bound genes using ChIP-chip assays in neuroblastoma, we found lif as a putative N-Myc bound gene with a number of strong N-Myc binding peaks in the promoter region enriched for E-boxes. Amongst putative N-Myc target genes in expression microarray studies in neuroblastoma we also found lif and three additional important embryonic stem cell (ESC-related factors that are linked to production of iPSC: klf2, klf4, and lin28b. To examine the regulation of these genes by N-Myc, we measured their expression using neuroblastoma cells that contain a Tet-regulatable N-myc transgene (TET21N as well as NSC with a nestin-cre driven N-myc knockout. N-myc levels closely correlated with the expression of all of these genes in neuroblastoma and all but lif in NSC. Direct ChIP assays also indicate that N-Myc directly binds the lif promoter. N-Myc regulates trimethylation of lysine 4 of histone H3 in the promoter of lif and possibly in the promoters of several other stem-related genes. Together these findings indicate that N-Myc regulates overlapping stem-related gene expression programs in neuroblastoma and NSC, supporting a novel model by which amplification of the N-myc gene may drive formation of neuroblastoma. They also suggest mechanisms by which Myc proteins more generally contribute to maintenance of pluripotency and self-renewal of ESC as

  13. Food irradiation

    International Nuclear Information System (INIS)

    Macklin, M.

    1987-01-01

    The Queensland Government has given its support the establishment of a food irradiation plant in Queensland. The decision to press ahead with a food irradiation plant is astonishing given that there are two independent inquiries being carried out into food irradiation - a Parliamentary Committee inquiry and an inquiry by the Australian Consumers Association, both of which have still to table their Reports. It is fair to assume from the Queensland Government's response to date, therefore, that the Government will proceed with its food irradiation proposals regardless of the outcomes of the various federal inquiries. The reasons for the Australian Democrats' opposition to food irradiation which are also those of concerned citizens are outlined

  14. Food irradiation

    International Nuclear Information System (INIS)

    Duchacek, V.

    1989-01-01

    The ranges of doses used for food irradiation and their effect on the processed foods are outlined. The wholesomeness of irradiated foods is discussed. The present food irradiation technology development in the world is described. A review of the irradiated foods permitted for public consumption, the purposes of food irradiaton, the doses used and a review of the commercial-scale food irradiators are tabulated. The history and the present state of food processing in Czechoslovakia are described. (author). 1 fig., 3 tabs., 13 refs

  15. Irradiated foods

    International Nuclear Information System (INIS)

    Darrington, Hugh

    1988-06-01

    This special edition of 'Food Manufacture' presents papers on the following aspects of the use of irradiation in the food industry:- 1) an outline view of current technology and its potential. 2) Safety and wholesomeness of irradiated and non-irradiated foods. 3) A review of the known effects of irradiation on packaging. 4) The problems of regulating the use of irradiation and consumer protection against abuse. 5) The detection problem - current procedures. 6) Description of the Gammaster BV plant in Holland. 7) World outline review. 8) Current and future commercial activities in Europe. (U.K.)

  16. PIV and LIF study of flow and thermal fields of twine plumes in water

    Directory of Open Access Journals (Sweden)

    Broučková Zuzana

    2017-01-01

    Full Text Available Flow and thermal fields of a pair of plane plumes in water are investigated by means of PIV and LIF experiments. The plumes are generated from thermal line sources, which are made out of electrically heated cylinders with a diameter of D = 1.21 mm. A cylinder-to-cylinder distance was 17.9 D. Either continuous or pulsating heating were used with the same heating input power. Because the cylinder-to-cylinder distance is moderately small, deflections of plumes from a vertical direction occur and the plumes are inclined together. This behavior is caused by a confined entrainment from a space between the both plumes. For a continuous heating, low frequency oscillations were identified and the natural frequency was evaluated as 0.5 Hz. Based on this finding, pulsating heating was used at the subharmonic frequency of 0.25 Hz. The maximum time-mean velocity magnitude at the continuous and pulsating heating were commensurable, approximately 0.007 m/s. On the other hand, pulsating heating achieves by 36 % higher velocity peaks. A very strong velocity oscillations were generated by pulsating heating at the distance approximately 8.3 D above the cylinders, where the velocity maxima oscillate along the time-mean value of 0.0057 m/s from −30% to +70 %. Temperature fields reasonably agree with this findings, despite a relatively fast equalization of the temperature field was concluded. The results demonstrate enhancement effects of pulsations in flow/thermal fields.

  17. Preparation of thermoluminescent dosimeters of LiF: Mg, Cu, P + Ptfe for environmental radiological monitoring and radiodiagnosis; Preparacion de dosimetros termoluminiscentes de LiF: Mg, Cu, P + PTFE para monitoreo radiologico ambiental y radiodiagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez L, A

    1997-12-31

    The necessity of finding a thermoluminescent material for measuring gamma and X radiation in applications like environmental monitoring, personnel dosimetry and biomedical sciences (radiotherapy and radiodiagnosis), but with special characteristics such as low umbral detection, independence of the energy of radiation and equivalency with the tissue. This made us think in lithium fluoride activated with magnesium, copper and phosphorous (LiF: Mg, Cu, P). In this thesis I developed this material chips like shape embedded in polytetrafluoroethylene (LiF: Mg, Cu, P+Ptfe). The chapter 1 and 2 talk about the atom is conformed and the interaction of the radiation with the matter. The requirements of Tl material, types of dosimetry system, biological effects and units of measurements are discussed in chapter 3 as well as the recommended limits of the International Commission on Radiological Protection ICRP. Chapter 4 shows aspects of the thermoluminescence phenomenon and describes, at the same time, the determination of the most important thermoluminescent parameters (kinetic order, energy or trap depth and the frequency factor). Chapter 5 describes the major characteristics and properties of Tl materials and its requirements for dosimetric use. Chapter 6 deals with the preparations of LiF: Mg, Cu, P+Ptfe chips and some tests for improving its sensitivity, describes the dosimetric tests and requirements proposed by American National Standard Institute ANSI-N545 Like: umbral of detection, homogeneity, fading, repeatability, linearity, effects of UV and fluorescent light etc. Finally in chapter 7 I do a report about analysis of results, conclusions and some recommendations. (Author).

  18. Foodstuff irradiation

    International Nuclear Information System (INIS)

    1982-01-01

    Report written on behalf of the Danish Food Institute summarizes national and international rules and developments within food irradiation technology, chemical changes in irradiated foodstuffs, microbiological and health-related aspects of irradiation and finally technological prospects of this conservation form. Food irradiatin has not been hitherto applied in Denmark. Radiation sources and secondary radiation doses in processed food are characterized. Chemical changes due to irradiation are compared to those due to p.ex. food heating. Toxicological and microbiological tests and their results give no unequivocal answer to the problem whether a foodstuff has been irradiated. The most likely application fields in Denmark are for low radiation dosis inhibition of germination, riping delay and insecticide. Medium dosis (1-10 kGy) can reduce bacteria number while high dosis (10-50 kGy) will enable total elimination of microorganisms and viruses. Food irradiation can be acceptable as technological possibility with reservation, that further studies follow. (EG)

  19. Hemibody irradiation

    International Nuclear Information System (INIS)

    Schen, B.C.; Mella, O.; Dahl, O.

    1992-01-01

    In a large number of cancer patients, extensive skeletal metastases or myelomatosis induce vast suffering, such as intolerable pain and local complications of neoplastic bone destruction. Analgetic drugs frequently do not yield sufficient palliation. Irradiation of local fields often has to be repeated, because of tumour growth outside previously irradiated volumes. Wide field irradiation of the lower or upper half of the body causes significant relief of pain in most patients. Adequate pretreatment handling of patients, method of irradiation, and follow-up are of importance to reduce side effects, and are described as they are carried out at the Department of Oncology, Haukeland Hospital, Norway. 16 refs., 2 figs

  20. Determination of absorbed dose in crystalline and thyroid gland with irradiation protocols applied in orthopantomography equipment for dental examination; Determinacion de dosis absorbida en cristalino y glandula tiroides con protocolos de irradiacion aplicados en equipos de ortopantomografia para panoramica dental

    Energy Technology Data Exchange (ETDEWEB)

    Munoz A, A. A.; Ramirez A, L. M. [Instituto Tecnologico Metropolitano, Grupo de Investigacion e Innovacion Biomedica, Medellin, Antioquia (Colombia); Sosa A, M. A.; Azorin V, J. C.; Vallejo H, M. A. [Universidad de Guanajuato, Departamento de Fisica, Loma del Bosque 103, Lomas del Campestre, 37150 Leon, Guanajuato (Mexico)

    2016-10-15

    Ionizing radiations are very useful in the medical field for the diagnostic use of different pathologies. Currently there are different technologies for diagnostic imaging using conventional X-ray, computed tomography, mammography, angiography, dental panoramic X-ray, among others. However, it should be noted that exposure to radiation in this type of diagnostic tests has increased considerably in recent years, because radiological examinations are not always carried out according to the actual clinical needs of each patient, increasing the risk to develop cancer. In this paper, the absorbed dose in the lens and thyroid gland was measured with the help of TLD-100 dosimeters located in a PMMA phantom adapted for orthopantomography (dental panoramic X-ray) equipment in 5 hospitals; using the parameters pre-configured for normal adult for irradiation. A Harshaw 3500 equipment was used to read the dosimeters, obtaining a value of 1.324 ± Sd 0.01 mGy for crystalline and 1.044 ± Sd 0.03 mGy values which are intended to be validated under other conditions and protocols. (Author)

  1. Preparation of thermoluminescent dosimeters of LiF: Mg, Cu, P + Ptfe for environmental radiological monitoring and radiodiagnosis

    International Nuclear Information System (INIS)

    Ramirez L, A.

    1996-01-01

    The necessity of finding a thermoluminescent material for measuring gamma and X radiation in applications like environmental monitoring, personnel dosimetry and biomedical sciences (radiotherapy and radiodiagnosis), but with special characteristics such as low umbral detection, independence of the energy of radiation and equivalency with the tissue. This made us think in lithium fluoride activated with magnesium, copper and phosphorous (LiF: Mg, Cu, P). In this thesis I developed this material chips like shape embedded in polytetrafluoroethylene (LiF: Mg, Cu, P+Ptfe). The chapter 1 and 2 talk about the atom is conformed and the interaction of the radiation with the matter. The requirements of Tl material, types of dosimetry system, biological effects and units of measurements are discussed in chapter 3 as well as the recommended limits of the International Commission on Radiological Protection ICRP. Chapter 4 shows aspects of the thermoluminescence phenomenon and describes, at the same time, the determination of the most important thermoluminescent parameters (kinetic order, energy or trap depth and the frequency factor). Chapter 5 describes the major characteristics and properties of Tl materials and its requirements for dosimetric use. Chapter 6 deals with the preparations of LiF: Mg, Cu, P+Ptfe chips and some tests for improving its sensitivity, describes the dosimetric tests and requirements proposed by American National Standard Institute ANSI-N545 Like: umbral of detection, homogeneity, fading, repeatability, linearity, effects of UV and fluorescent light etc. Finally in chapter 7 I do a report about analysis of results, conclusions and some recommendations. (Author)

  2. High-pressure and high-temperature physical properties of LiF studied by density functional theory calculations and molecular dynamics simulations

    Science.gov (United States)

    Sun, Xiao-Wei; Liu, Zi-Jiang; Quan, Wei-Long; Song, Ting; Khenata, Rabah; Bin-Omran, Saad

    2018-05-01

    Using the revised Perdew-Burke-Ernzerhof generalized gradient approximation based on first-principles plane-wave pseudopotential density functional theory, the high-pressure structural phase transition of LiF is explored. From the analysis of Gibbs free energies, we find that no phase transition occurs for LiF in the presented pressure range from 0 to 1000 GPa, and this result is consistent with the theoretical prediction obtained via ab initio calculations [N.A. Smirnov, Phys. Rev. B 83 (2011) 014109]. Using the classical molecular dynamics technique with effective pair potentials which consist of the Coulomb, dispersion, and repulsion interaction, the melting phase diagram of LiF is determined. The obtained normalized volumes under pressure are in good agreement with our density functional theory results and the available experimental data. Meanwhile, with the help of the quasi-harmonic Debye model in which the phononic effects are considered, the thermodynamic properties of interest, including the volume thermal expansion coefficient, isothermal bulk modulus and its first and second pressure derivatives, heat capacity at constant volume, entropy, Debye temperature, and Grüneisen parameter of LiF are predicted systematically. All the properties of LiF with the stable NaCl-type structure in the temperature range of 0-4900 K and the pressure up to 1000 GPa are summarized.

  3. Ionizing radiation source detection by personal TLD

    International Nuclear Information System (INIS)

    Marinkovic, O.; Mirkov, Z.

    2002-01-01

    The Laboratory for personal dosimetry has about 3000 workers under control. The most of them work in medicine. Some institutions, as big health centers, have different ionizing radiation sources. It is usefull to analyze what has been the source of irradiation, special when appears a dosimeter with high dose. Personal dosimetry equipment is Harshaw TLD Reader Model 6600 and dosimeters consist of two chips LiF TLD-100 assembled in bar-coded cards which are wearing in holders with one tissue-equivalent filter (to determine H(10)) and skin-equivalent the other (to determine H(0.07)). The calibration dosimeters have been irradiated in holders by different sources: x-ray (for 80keV and 100keV), 6 0C o, 9 0S r (for different distances from beta source) and foton beem (at radiotherapy accelerator by 6MeV, 10MeV and 18MeV). The dose ratio for two LiF cristals was calculated and represented with graphs. So, it is possible to calculate the ratio H(10)/H(0.07) for a personal TLD and analyze what has been the source of irradiation. Also, there is the calibration for determination the time of irradiation, according to glow curve deconvolution

  4. Diffraction of 4He atoms from the (001) face of LiF at 10 deg K

    International Nuclear Information System (INIS)

    Boato, G.; Cantini, P.; Cardillo, M.J.; Tatarek, R.

    1974-01-01

    A new atom-surface scattering apparatus, which takes advantage of the use of low temperatures, is described. The apparatus allows differential cross section measurements to be carried out with good angular resolution and sensitivity, holding the surface around liquid helium temperatures. The diffractive scattering of a supersonic helium beam from a (001) cleaved LiF surface at 10 deg K was studied. The normalized integrated intensities of all diffracted peaks for normal incidence are given and compared with a quantum surface rainbow theory developed by LEVI et al. The observation of bound state resonances in the peak intensity plotted as a function of incident angle is discussed

  5. Fast atom diffraction for grazing scattering of Ne atoms from a LiF(0 0 1) surface

    International Nuclear Information System (INIS)

    Gravielle, M.S.; Schueller, A.; Winter, H.; Miraglia, J.E.

    2011-01-01

    Angular distributions of fast Ne atoms after grazing collisions with a LiF(0 0 1) surface under axial surface channeling conditions are experimentally and theoretically studied. We use the surface eikonal approximation to describe the quantum interference of scattered projectiles, while the atom-surface interaction is represented by means of a pairwise additive potential, including the polarization of the projectile atom. Experimental data serve as a benchmark to investigate the performance of the proposed potential model, analyzing the role played by the projectile polarization.

  6. Quantum interference in grazing scattering of swift He atoms from LiF(0 0 1) surfaces: Surface eikonal approximation

    Energy Technology Data Exchange (ETDEWEB)

    Gravielle, M.S. [Instituto de Astronomia y Fisica del Espacio, CONICET, Casilla de Correo 67, Sucursal 28, 1428 Buenos Aires (Argentina); Dpto. de Fisica, FCEN, Universidad de Buenos Aires, Buenos Aires (Argentina)], E-mail: msilvia@iafe.uba.ar; Miraglia, J.E. [Instituto de Astronomia y Fisica del Espacio, CONICET, Casilla de Correo 67, Sucursal 28, 1428 Buenos Aires (Argentina); Dpto. de Fisica, FCEN, Universidad de Buenos Aires, Buenos Aires (Argentina)

    2009-02-15

    This work deals with the interference effects recently observed in grazing collisions of few-keV atoms with insulator surfaces. The process is studied within a distorted-wave method, the surface eikonal approximation, based on the use of the eikonal wave function and involving axial channeled trajectories with different initial conditions. The theory is applied to helium atoms impinging on a LiF(0 0 1) surface along the <1 1 0> direction. The role played by the projectile polarization and the surface rumpling is investigated. We found that when both effects are included, the proposed eikonal approach provides angular projectile spectra in good agreement with the experimental findings.

  7. Quantum interference in grazing scattering of swift He atoms from LiF(0 0 1) surfaces: Surface eikonal approximation

    International Nuclear Information System (INIS)

    Gravielle, M.S.; Miraglia, J.E.

    2009-01-01

    This work deals with the interference effects recently observed in grazing collisions of few-keV atoms with insulator surfaces. The process is studied within a distorted-wave method, the surface eikonal approximation, based on the use of the eikonal wave function and involving axial channeled trajectories with different initial conditions. The theory is applied to helium atoms impinging on a LiF(0 0 1) surface along the direction. The role played by the projectile polarization and the surface rumpling is investigated. We found that when both effects are included, the proposed eikonal approach provides angular projectile spectra in good agreement with the experimental findings.

  8. Fast atom diffraction for grazing scattering of Ne atoms from a LiF(0 0 1) surface

    Energy Technology Data Exchange (ETDEWEB)

    Gravielle, M.S., E-mail: msilvia@iafe.uba.ar [Instituto de Astronomia y Fisica del Espacio (CONICET-UBA), Casilla de correo 67, sucursal 28 C1428EGA, Buenos Aires (Argentina); Departamento de Fisica, Fac. de Ciencias Exactas y Naturales, Universidad de Buenos Aires (Argentina); Schueller, A.; Winter, H. [Institut fuer Physik, Humboldt Universitaet zu Berlin, Newtonstrasse 15, D-12489 Berlin-Adlershof (Germany); Miraglia, J.E. [Instituto de Astronomia y Fisica del Espacio (CONICET-UBA), Casilla de correo 67, sucursal 28 C1428EGA, Buenos Aires (Argentina); Departamento de Fisica, Fac. de Ciencias Exactas y Naturales, Universidad de Buenos Aires (Argentina)

    2011-06-01

    Angular distributions of fast Ne atoms after grazing collisions with a LiF(0 0 1) surface under axial surface channeling conditions are experimentally and theoretically studied. We use the surface eikonal approximation to describe the quantum interference of scattered projectiles, while the atom-surface interaction is represented by means of a pairwise additive potential, including the polarization of the projectile atom. Experimental data serve as a benchmark to investigate the performance of the proposed potential model, analyzing the role played by the projectile polarization.

  9. Investigation of high frequency external perturbation effects on flow in a T-shape microchannel by μLIF technique

    Science.gov (United States)

    Kravtsova, A. Yu; Meshalkin, Yu E.; Bilsky, A. V.

    2017-11-01

    Investigation of high frequency external perturbation effect on flow inside T-shape microchannel was examined. In-phase pulsations of different frequencies were added to both inlets of the T-shaped microchannel to study mixing by means of Micro Laser Induced Fluorescence (μLIF) technique. For all flow regimes studied, mixing enhancement was obtained. Significant enhancement can be achieved at the beginning of the outlet channel operating in steady asymmetric regime (Re=186) by forcing at certain frequency ranges (f = 500Hz, f = 800Hz). Mixing suppression was also observed for two flow regimes (Re = 400, f = 1000Hz) and (Re = 120, f = 700Hz).

  10. Electron spin-lattice relaxation of low-symmetry Ni.sup.2+./sup. centers in LiF

    Czech Academy of Sciences Publication Activity Database

    Azamat, Dmitry; Badalyan, A. G.; Dejneka, Alexandr; Jastrabík, Lubomír; Lančok, Ján

    2014-01-01

    Roč. 104, č. 25 (2014), "252902-1"-"252902-4" ISSN 0003-6951 R&D Projects: GA MŠk(CZ) LM2011029; GA TA ČR TA01010517; GA ČR GAP108/12/1941 Grant - others:SAFMAT(XE) CZ.2.16/3.1.00/22132 Institutional support: RVO:68378271 Keywords : Ni 2+ centers * LiF single crystals * electron spin-lattice relaxation * electron spin echo technique Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 3.302, year: 2014

  11. Vertical incidence of slow Ne{sup 10+} ions on an LiF surface: Suppression of the trampoline effect

    Energy Technology Data Exchange (ETDEWEB)

    Wirtz, Ludger E-mail: lwirtz@concord.itp.tuwien.ac.at; Lemell, Christoph; Reinhold, Carlos O.; Haegg, Lotten; Burgdoerfer, Joachim

    2001-08-01

    We present a Monte Carlo simulation of the neutralization of a slow Ne{sup 10+} ion in vertical incidence on an LiF(1 0 0) surface. The rates for resonant electron transfer between surface F{sup -} ions and the projectile are calculated using a classical trajectory Monte Carlo simulation. We investigate the influence of the hole mobility on the neutralization sequence. It is shown that backscattering above the surface due to the local positive charge up of the surface ('trampoline effect') does not take place.

  12. Vertical incidence of slow Ne 10+ ions on an LiF surface: Suppression of the trampoline effect

    Science.gov (United States)

    Wirtz, Ludger; Lemell, Christoph; Reinhold, Carlos O.; Hägg, Lotten; Burgdörfer, Joachim

    2001-08-01

    We present a Monte Carlo simulation of the neutralization of a slow Ne 10+ ion in vertical incidence on an LiF(1 0 0) surface. The rates for resonant electron transfer between surface F - ions and the projectile are calculated using a classical trajectory Monte Carlo simulation. We investigate the influence of the hole mobility on the neutralization sequence. It is shown that backscattering above the surface due to the local positive charge up of the surface ("trampoline effect") does not take place.

  13. Vertical incidence of slow Ne10+ ions on an LiF surface: Suppression of the trampoline effect

    International Nuclear Information System (INIS)

    Wirtz, Ludger; Lemell, Christoph; Reinhold, Carlos O.; Haegg, Lotten; Burgdoerfer, Joachim

    2001-01-01

    We present a Monte Carlo simulation of the neutralization of a slow Ne 10+ ion in vertical incidence on an LiF(1 0 0) surface. The rates for resonant electron transfer between surface F - ions and the projectile are calculated using a classical trajectory Monte Carlo simulation. We investigate the influence of the hole mobility on the neutralization sequence. It is shown that backscattering above the surface due to the local positive charge up of the surface ('trampoline effect') does not take place

  14. Improvements in the preparation and areal characterisation of {sup 10}B and {sup 6}LiF reference deposits

    Energy Technology Data Exchange (ETDEWEB)

    Pauwels, J. [Commission of the European Communities, Geel (Belgium). Joint Research Centre; Scott, R.D. [Commission of the European Communities, Geel (Belgium). Joint Research Centre; Eykens, R. [Commission of the European Communities, Geel (Belgium). Joint Research Centre; Robouch, P. [Commission of the European Communities, Geel (Belgium). Joint Research Centre; Van Gestel, J. [Commission of the European Communities, Geel (Belgium). Joint Research Centre; Verdonck, J. [Commission of the European Communities, Geel (Belgium). Joint Research Centre; Gilliam, D.M. [National Inst. of Standards and Technology, Gaithersburg, MD (United States); Greene, G. [National Inst. of Standards and Technology, Gaithersburg, MD (United States)

    1995-08-01

    The preparation and characterisation of a new series of {sup 10}B and {sup 6}LiF reference deposits for accurate neutron fluence rate measurements are described and compared to those of an earlier campaign. Important improvements have been made by designing and building a new planetary rotating substrate holder and by using an optimized vacuum deposition set-up. Both deposition homogeneity and edge sharpness were significantly improved. However, a hitherto unrecognized source of border effect, i.e. mask expansion during the vacuum deposition process, was observed and discussed. (orig.).

  15. Food irradiation

    International Nuclear Information System (INIS)

    Mercader, J.P.; Emily Leong

    1985-01-01

    The paper discusses the need for effective and efficient technologies in improving the food handling system. It defines the basic premises for the development of food handling. The application of food irradiation technology is briefly discussed. The paper points out key considerations for the adoption of food irradiation technology in the ASEAN region (author)

  16. Food irradiation

    International Nuclear Information System (INIS)

    Matsuyama, Akira

    1990-01-01

    This paper reviews researches, commentaries, and conference and public records of food irradiation, published mainly during the period 1987-1989, focusing on the current conditions of food irradiation that may pose not only scientific or technologic problems but also political issues or consumerism. Approximately 50 kinds of food, although not enough to fill economic benefit, are now permitted for food irradiation in the world. Consumerism is pointed out as the major factor that precludes the feasibility of food irradiation in the world. In the United States, irradiation is feasible only for spices. Food irradiation has already been feasible in France, Hollands, Belgium, and the Soviet Union; has under consideration in the Great Britain, and has been rejected in the West Germany. Although the feasibility of food irradiation is projected to increase gradually in the future, commercial success or failure depends on the final selection of consumers. In this respect, the role of education and public information are stressed. Meat radicidation and recent progress in the method for detecting irradiated food are referred to. (N.K.) 128 refs

  17. Irradiation proctitis

    International Nuclear Information System (INIS)

    Minami, Akira

    1977-01-01

    Literatures on late rectal injuries are discussed, referring to two patients with uterine cervical cancer in whom irradiation proctitis occurred after telecobalt irradiation following uterine extirpation. To one patients, a total of 5000 rads was irradiated, dividing into 250 rads at one time, and after 3 months, irradiation with a total of 2000 rads, dividing into 200 rads at one time, was further given. In another one patient, two parallel opposing portal irradiation with a total of 6000 rads was given. About a year after the irradiation, rectal injuries and cystitis, accompanying with hemorrhage, were found in both of the patients. Rectal amputation and proctotoreusis were performed. Cystitis was treated by cystic irradiation in the urological department. Pathohistological studies of the rectal specimen revealed atrophic mucosa, and dilatation of the blood vessels and edema in the colonic submucosa. Incidence of this disease, term when the disease occurs, irradiation dose, type of the disease, treatment and prevention are described on the basis of the literatures. (Kanao, N.)

  18. Irradiation proctitis

    Energy Technology Data Exchange (ETDEWEB)

    Minami, A [Osaka Kita Tsishin Hospital (Japan)

    1977-06-01

    Literatures on late rectal injuries are discussed, referring to two patients with uterine cervical cancer in whom irradiation proctitis occurred after telecobalt irradiation following uterine extirpation. To one patients, a total of 5000 rads was irradiated, dividing into 250 rads at one time, and after 3 months, irradiation with a total of 2000 rads, dividing into 200 rads at one time, was further given. In another one patient, two parallel opposing portal irradiation with a total of 6000 rads was given. About a year after the irradiation, rectal injuries and cystitis, accompanying with hemorrhage, were found in both of the patients. Rectal amputation and proctotoreusis were performed. Cystitis was treated by cystic irradiation in the urological department. Pathohistological studies of the rectal specimen revealed atrophic mucosa, and dilatation of the blood vessels and edema in the colonic submucosa. Incidence of this disease, term when the disease occurs, irradiation dose, type of the disease, treatment and prevention are described on the basis of the literatures.

  19. LIBS-LIF-Raman: a new tool for the future E-RIHS

    Science.gov (United States)

    Detalle, Vincent; Bai, Xueshi; Bourguignon, Elsa; Menu, Michel; Pallot-Frossard, Isabelle

    2017-07-01

    the creation of new mobile instrumentation, the French institutions are involved in the development of LIBS/LIF/RAMAN portable instrumentation. After a presentation of the challenge and the multiple advantages in building the European Infrastructure and of the French E-RIHS hub, the major interests of associating the three lasers based on analytical methods for a more global and precise characterization of the heritage objects taking into account their precious characters and their specific constraints. Lastly some preliminary results will be presented in order to give a first idea of the power of this analytical tool.

  20. Food irradiation

    International Nuclear Information System (INIS)

    Kobayashi, Yasuhiko; Kikuchi, Masahiro

    2009-01-01

    Food irradiation can have a number of beneficial effects, including prevention of sprouting; control of insects, parasites, pathogenic and spoilage bacteria, moulds and yeasts; and sterilization, which enables commodities to be stored for long periods. It is most unlikely that all these potential applications will prove commercially acceptable; the extend to which such acceptance is eventually achieved will be determined by practical and economic considerations. A review of the available scientific literature indicates that food irradiation is a thoroughly tested food technology. Safety studies have so far shown no deleterious effects. Irradiation will help to ensure a safer and more plentiful food supply by extending shelf-life and by inactivating pests and pathogens. As long as requirement for good manufacturing practice are implemented, food irradiation is safe and effective. Possible risks of food irradiation are not basically different from those resulting from misuse of other processing methods, such as canning, freezing and pasteurization. (author)

  1. Irradiation damage

    Energy Technology Data Exchange (ETDEWEB)

    Howe, L.M

    2000-07-01

    There is considerable interest in irradiation effects in intermetallic compounds from both the applied and fundamental aspects. Initially, this interest was associated mainly with nuclear reactor programs but it now extends to the fields of ion-beam modification of metals, behaviour of amorphous materials, ion-beam processing of electronic materials, and ion-beam simulations of various kinds. The field of irradiation damage in intermetallic compounds is rapidly expanding, and no attempt will be made in this chapter to cover all of the various aspects. Instead, attention will be focused on some specific areas and, hopefully, through these, some insight will be given into the physical processes involved, the present state of our knowledge, and the challenge of obtaining more comprehensive understanding in the future. The specific areas that will be covered are: point defects in intermetallic compounds; irradiation-enhanced ordering and irradiation-induced disordering of ordered alloys; irradiation-induced amorphization.

  2. Irradiation damage

    International Nuclear Information System (INIS)

    Howe, L.M.

    2000-01-01

    There is considerable interest in irradiation effects in intermetallic compounds from both the applied and fundamental aspects. Initially, this interest was associated mainly with nuclear reactor programs but it now extends to the fields of ion-beam modification of metals, behaviour of amorphous materials, ion-beam processing of electronic materials, and ion-beam simulations of various kinds. The field of irradiation damage in intermetallic compounds is rapidly expanding, and no attempt will be made in this chapter to cover all of the various aspects. Instead, attention will be focused on some specific areas and, hopefully, through these, some insight will be given into the physical processes involved, the present state of our knowledge, and the challenge of obtaining more comprehensive understanding in the future. The specific areas that will be covered are: point defects in intermetallic compounds; irradiation-enhanced ordering and irradiation-induced disordering of ordered alloys; irradiation-induced amorphization

  3. Navázání svazku Ti:Sa laseru do interakční komory v sestavě LIBS+LIFS

    OpenAIRE

    Vémola, Tomáš

    2009-01-01

    Práce se zabývá problematikou navázání svazku Ti:Safírového laseru do interakní komory v soustavě LIBS+LIFS. Cílem je navrhnout optickou soustavu s požadovanými vlastnostmi. Součástí práce je i teoretický popis základních principů atomové spektroskopie s důrazem na metodu LIBS+LIFS. In this work, the problem of focusing Ti:Sapphire laser beam into LIBS+LIFS interaction chamber is resolved. The task is to design an optical setup with demanded properties. Short theoretical description of the...

  4. Wnt/β-catenin and LIF-Stat3 signaling pathways converge on Sp5 to promote mouse embryonic stem cell self-renewal.

    Science.gov (United States)

    Ye, Shoudong; Zhang, Dongming; Cheng, Fei; Wilson, Daniel; Mackay, Jeffrey; He, Kan; Ban, Qian; Lv, Feng; Huang, Saifei; Liu, Dahai; Ying, Qi-Long

    2016-01-15

    Activation of leukemia inhibitor factor (LIF)-Stat3 or Wnt/β-catenin signaling promotes mouse embryonic stem cell (mESC) self-renewal. A myriad of downstream targets have been identified in the individual signal pathways, but their common targets remain largely elusive. In this study, we found that the LIF-Stat3 and Wnt/β-catenin signaling pathways converge on Sp5 to promote mESC self-renewal. Forced Sp5 expression can reproduce partial effects of Wnt/β-catenin signaling but mimics most features of LIF-Stat3 signaling to maintain undifferentiated mESCs. Moreover, Sp5 is able to convert mouse epiblast stem cells into a naïve pluripotent state. Thus, Sp5 is an important component of the regulatory network governing mESC naïve pluripotency. © 2016. Published by The Company of Biologists Ltd.

  5. Analysis of rocking curve measurements of LiF flight crystals for the objective crystal spectrometer on SPECTRUM-X-GAMMA

    DEFF Research Database (Denmark)

    Halm, I.; Wiebicke, H.-J.; Geppert, U.R.M.E.

    1993-01-01

    The Objective Crystal Spectrometer on the SPECTRUM-X-GAMMA satellite will use three types of natural crystals LiF(220), Si(111), RAP(001), and a multilayer structure providing high-resolution X- ray spectroscopy of Fe, S, O, and C line regions of bright cosmic X-ray sources. 330 - 360 LiF(220......) crystals of dimensions approximately 23 × 63 mm2 are required to cover one side of a large (1000 × 600 mm2) panel, which is to be mounted in front of one of two high throughput X- ray telescopes. Rocking curves of 441 LiF(220) crystals measured by using an expanded Cu - Kα2 beam were analyzed to select...... the main parameters of the rocking curve averaged over all crystals can be improved at least by a factor of 1.6 both in full width half maximum and peak reflectivity....

  6. Progesterone is essential for protecting against LPS-induced pregnancy loss. LIF as a potential mediator of the anti-inflammatory effect of progesterone.

    Directory of Open Access Journals (Sweden)

    Julieta Aisemberg

    Full Text Available Lipopolysaccharide (LPS administration to mice on day 7 of gestation led to 100% embryonic resorption after 24 h. In this model, nitric oxide is fundamental for the resorption process. Progesterone may be responsible, at least in part, for a Th2 switch in the feto-maternal interface, inducing active immune tolerance against fetal antigens. Th2 cells promote the development of T cells, producing leukemia inhibitory factor (LIF, which seems to be important due to its immunomodulatory action during early pregnancy. Our aim was to evaluate the involvement of progesterone in the mechanism of LPS-induced embryonic resorption, and whether LIF can mediate hormonal action. Using in vivo and in vitro models, we provide evidence that circulating progesterone is an important component of the process by which infection causes embryonic resorption in mice. Also, LIF seems to be a mediator of the progesterone effect under inflammatory conditions. We found that serum progesterone fell to very low levels after 24 h of LPS exposure. Moreover, progesterone supplementation prevented embryonic resorption and LPS-induced increase of uterine nitric oxide levels in vivo. Results show that LPS diminished the expression of the nuclear progesterone receptor in the uterus after 6 and 12 h of treatment. We investigated the expression of LIF in uterine tissue from pregnant mice and found that progesterone up-regulates LIF mRNA expression in vitro. We observed that LIF was able to modulate the levels of nitric oxide induced by LPS in vitro, suggesting that it could be a potential mediator of the inflammatory action of progesterone. Our observations support the view that progesterone plays a critical role in a successful pregnancy as an anti-inflammatory agent, and that it could have possible therapeutic applications in the prevention of early reproductive failure associated with inflammatory disorders.

  7. Vaginally administered PEGylated LIF antagonist blocked embryo implantation and eliminated non-target effects on bone in mice.

    Directory of Open Access Journals (Sweden)

    Ellen Menkhorst

    Full Text Available Female-controlled contraception/HIV prevention is critical to address health issues associated with gender inequality. Therefore, a contraceptive which can be administered in tandem with a microbicide to inhibit sexually transmitted infections, is desirable. Uterine leukemia inhibitory factor (LIF is obligatory for blastocyst implantation in mice and associated with infertility in women. We aimed to determine whether a PEGylated LIF inhibitor (PEGLA was an effective contraceptive following vaginal delivery and to identify non-uterine targets of PEGLA in mice.Vaginally-applied (125I-PEGLA accumulated in blood more slowly (30 min vs 10 min and showed reduced tissue and blood retention (24 h vs 96 h compared to intraperitoneal injection in mice. Vaginally-applied PEGLA blocked implantation. PEGLA administered by intraperitoneal injection inhibited bone remodelling whereas vaginally-applied PEGLA had no effect on bone. Further, PEGLA had no effect in an animal model of multiple sclerosis, experimental auto-immune encephalomyelitis, suggesting PEGLA cannot target the central nervous system.Vaginally-administered PEGLA is a promising non-hormonal contraceptive, one which could be delivered alone, or in tandem with a microbicide. Vaginal application reduced the total dose of PEGLA required to block implantation and eliminated the systemic effect on bone, showing the vagina is a promising site of administration for larger drugs which target organs within the reproductive tract.

  8. Magnetic flux and heat losses by diffusive, advective, and Nernst effects in MagLIF-like plasma

    International Nuclear Information System (INIS)

    Velikovich, A. L.; Giuliani, J. L.; Zalesak, S. T.

    2014-01-01

    The MagLIF approach to inertial confinement fusion involves subsonic/isobaric compression and heating of a DT plasma with frozen-in magnetic flux by a heavy cylindrical liner. The losses of heat and magnetic flux from the plasma to the liner are thereby determined by plasma advection and gradient-driven transport processes, such as thermal conductivity, magnetic field diffusion and thermomagnetic effects. Theoretical analysis based on obtaining exact self-similar solutions of the classical collisional Braginskii's plasma transport equations in one dimension demonstrates that the heat loss from the hot plasma to the cold liner is dominated by the transverse heat conduction and advection, and the corresponding loss of magnetic flux is dominated by advection and the Nernst effect. For a large electron Hall parameter ω e τ e effective diffusion coefficients determining the losses of heat and magnetic flux are both shown to decrease with ω e τ e as does the Bohm diffusion coefficient, which is commonly associated with low collisionality and two-dimensional transport. This family of exact solutions can be used for verification of codes that model the MagLIF plasma dynamics

  9. 2-d LIF measurements of the thermo-acoustic phenomena in lean premixed flames of a gas turbine combustor

    Energy Technology Data Exchange (ETDEWEB)

    Bombach, R.; Hubschmid, W.; Inauen, A.; Kreutner, W.; Schenker, S.; Flohr, P.; Haffner, K.; Motz, C.; Paschereit, C.O.; Schuermans, B.; Zajadatz, M.

    2003-03-01

    Thermo-acoustic phenomena give rise to pressure oscillations in lean premixed flames of gas turbines at distinct frequencies characteristic of the burner design and its operation. They can lead to early materials ageing or even severe damages. Therefore, a detailed understanding of the underlying principles is fundamental for gas turbine design and improvement. In order to study the coupling between the heat release and the acoustics in the combustor as well as their feedback to the fuel/air premixing, upstream of the combustion chamber, phase-locked 2-D laser-induced fluorescence (LIF) measurements of the hydroxyl radical (OH) and acetone, respectively, have been performed. These experiments were carried out on a test rig equipped with a commercial 700 kW burner and a combustion chamber of UV transparent quartz, using a pulsed Nd:YAG/dye laser system and an intensified CCD camera for detection. Intensity variations in the integral OH LIF signal of up to {+-}10 % for one oscillation period are observed for peak sound pressure of 6 mbar and more. In addition, the phase-averaged position of the flame zone varies in axial direction, i.e. the main flow direction. The analysis shows that the observed flame motion is not only due to the acoustic motion of the gas itself, but is caused by a change of the flame velocity relative to the gas. (author)

  10. Lif Spectroscopy of ThF and the Preparation of ThF^{+} for the Jila eEDM Experiment

    Science.gov (United States)

    Ng, Kia Boon; Zhou, Yan; Gresh, Dan; Cairncross, William; Roussy, Tanya; Shagam, Yuval; Cheng, Lan; Ye, Jun; Cornell, Eric

    2017-06-01

    ThF^{+} is a promising candidate for a second-generation molecular ion-based measurement of the permanent electric dipole moment of the electron (eEDM). Compared to the current HfF^{+} eEDM experiment, ThF^{+} has several advantages: (i) the eEDM-sensitive ^{3}Δ_1 electronic state is the ground state, which facilitates a long measurement coherence time; (ii) its effective electric field (38 GV/cm) is 50% larger than that of HfF+, which promises a direct increase of the eEDM sensitivity; and (iii) the ionization energy of neutral ThF is lower than its dissociation energy, which introduces a greater flexibility for rotational state-selective photoionization via core-nonpenetrating Rydberg states. We use laser-induced fluorescence (LIF) spectroscopy to find suitable intermediate states required for the state selective ionization process. We present the results of our LIF spectroscopy of ThF, and our current progress on efficient ThF ionization and on ThF^{+} dissociation.

  11. The thermal neutron detection using 4H-SiC detectors with 6LiF conversion layer

    International Nuclear Information System (INIS)

    Zatko, B.; Bohacek, P.; Sekacova, M.; Arbet, J.; Sagatova, A.; Necas, V.

    2016-01-01

    In this paper we have examined 4H-SiC detector using a thermal neutron source and studied its detection properties. The detector was exposed to neutrons generated by 238 Pu-Be radiation source. The detection properties of 4H-SiC detectors were evaluated considering the use of the 6 LiF conversion. We prepared 4H-SiC Schottky contact detectors based on high-quality of epitaxial layer. The current-voltage characteristic show operating region between 100 V and 400 V. The detector was connected to the spectrometric set-up and used for detection of alpha particles from 241 Am. Following the 6 LiF conversion layer was applied on the Schottky contact of detector and the detection of thermal neutrons was performed. We are able to resolve alpha particles and tritons which are products of nuclear reaction between thermal neutrons and conversion layer. Also bare detector was used for neutron detection to clearly show significant influence of the used conversion layer.(authors)

  12. Hard x-ray contact microscopy with 250 nm spatial resolution using a LiF film detector and a tabletop microsource

    International Nuclear Information System (INIS)

    Almaviva, S.; Bonfigli, F.; Franzini, I.; Lai, A.; Montereali, R. M.; Pelliccia, D.; Cedola, A.; Lagomarsino, S.

    2006-01-01

    An innovative route for deep-submicrometer spatial resolution hard x-ray microscopy with tabletop x-ray source is proposed. A film of lithium fluoride (LiF) was used as imaging detector in contact mode. We present here the x-ray images recorded on LiF films of a Fresnel zone plate with submicrometer gold structures and of an onion cataphyll. The images were read with an optical confocal microscope in fluorescence mode. The measured spatial resolution was about 250 nm, i.e., close to the resolution limit of the confocal microscope. The advantages and drawbacks, and the possible improvements, of this route are discussed

  13. Food irradiation

    International Nuclear Information System (INIS)

    Hetherington, M.

    1989-01-01

    This popular-level article emphasizes that the ultimate health effects of irradiated food products are unknown. They may include vitamin loss, contamination of food by botulism bacteria, mutations in bacteria, increased production of aflatoxins, changes in food, carcinogenesis from unknown causes, presence of miscellaneous harmful chemicals, and the lack of a way of for a consumer to detect irradiated food. It is claimed that the nuclear industry is applying pressure on the Canadian government to relax labeling requirements on packages of irradiated food in order to find a market for its otherwise unnecessary products

  14. Food irradiation

    International Nuclear Information System (INIS)

    Luecher, O.

    1979-01-01

    Limitations of existing preserving methods and possibilities of improved food preservation by application of nuclear energy are explained. The latest state-of-the-art in irradiation technology in individual countries is described and corresponding recommendations of FAO, WHO and IAEA specialists are presented. The Sulzer irradiation equipment for potato sprout blocking is described, the same equipment being suitable also for the treatment of onions, garlic, rice, maize and other cereals. Systems with a higher power degree are needed for fodder preserving irradiation. (author)

  15. A study on structure defects in irradiated lithium fluoride (thermal neutrons); Etude des imperfections de structure du fluorure de lithium irradie (neutrons thermiques)

    Energy Technology Data Exchange (ETDEWEB)

    Lambert, M

    1958-06-19

    A study was made of the behavior of atomic defects, vacancies and interstitials, generated from the Li{sup 6}(n,{alpha})H{sup 3} reaction in Lip crystals. Defects appear as cavities and platelets around ten angstrom in size and increase both with neutron dose and annealing temperature. For longer irradiations, metallic lithium precipitates out, in epitaxy with LiF lattice, and later, lithium salts appear due to the penetration of atmospheric gases through the cracks present in the damaged crystal. Various x-ray experiments followed the formation and evolution of these imperfections when their atomic concentration reached 10{sup -4}. (author)

  16. Food irradiation

    International Nuclear Information System (INIS)

    Paganini, M.C.

    1991-06-01

    Food treatment by means of ionizing energy, or irradiation, is an innovative method for its preservation. In order to treat important volumes of food, it is necessary to have industrial irradiation installations. The effect of radiations on food is analyzed in the present special work and a calculus scheme for an Irradiation Plant is proposed, discussing different aspects related to its project and design: ionizing radiation sources, adequate civil work, security and auxiliary systems to the installations, dosimetric methods and financing evaluation methods of the project. Finally, the conceptual design and calculus of an irradiation industrial plant of tubercles is made, based on the actual needs of a specific agricultural zone of our country. (Author) [es

  17. Food irradiation

    International Nuclear Information System (INIS)

    Anon.

    1984-01-01

    Food preservation by irradiation is one part of Eisenhower's Atoms for Peace program that is enjoying renewed interest. Classified as a food additive by the Food, Drug, and Cosmetic Act of 1958 instead of a processing technique, irradiation lost public acceptance. Experiments have not been done to prove that there are no health hazards from gamma radiation, but there are new pressures to get Food and Drug Administration approval for testing in order to make commercial use of some radioactive wastes. Irradiation causes chemical reactions and nutritional changes, including the destruction of several vitamins, as well as the production of radiolytic products not normally found in food that could have adverse effects. The author concludes that, lacking epidemiological evidence, willing buyers should be able to purchase irradiated food as long as it is properly labeled

  18. Thermoluminescent signal fading of encapsulated lif: Mg,Ti detectors in PTFE-Teflon registered trademark

    International Nuclear Information System (INIS)

    Sasho Nikolovski, Sasho; Nikolovska, Lidija; Velevska, Marija; Velev, Velko

    2010-01-01

    Fading is a process when the latent information of a detector is unintentionally lost mainly due to the thermal influence. Thermoluminescent (TL) detectors have different sensitivities as far as the fading effect. Encapsulated TL detectors mounted within shielded filter holders are used during the personal monitoring of occupationally exposed persons in R. Macedonia. PTFE-Teflon registered trademark polymer is an example of encapsulation material that has a temperature resistance and it allows the luminescence signal to pass through. Since the encapsulated TL detectors cannot be submitted to annealing treatment in an oven, another fading reduction method is needed. The TL evaluation method suggested in this work is based on a specific glow-curve region. Irradiations were conducted using 90Sr/90Y source. Post-irradiation fade investigations were conducted for evaluation periods that varied up to 4 months. Two areas of the TL glow-curve were selected with the WimRems software. They correspond to the high and the low fading emission peaks (the lower temperature peaks display a greater degree of thermal fading than the higher temperature peaks). Post-irradiation fade is a contributing factor that affects the response of a thermoluminescent (TL) phosphor as a function of time. PTFE - Polytetrafluoroethylene most well known by the DuPont brand name Teflon registered trademark. (Author)

  19. Fruit irradiation

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    Food spoilage is a common problem when marketing agricultural products. Promising results have already been obtained on a number of food irradiating applications. A process is described in this paper where irradiation of sub-tropical fruits, especially mangoes and papayas, combined with conventional heat treatment results in effective insect and fungal control, delays ripening and greatly improves the quality of fruit at both export and internal markets

  20. Tissue irradiator

    International Nuclear Information System (INIS)

    Hungate, F.P.; Riemath, W.F.; Bunnell, L.R.

    1975-01-01

    A tissue irradiator is provided for the in-vivo irradiation of body tissue. The irradiator comprises a radiation source material contained and completely encapsulated within vitreous carbon. An embodiment for use as an in-vivo blood irradiator comprises a cylindrical body having an axial bore therethrough. A radioisotope is contained within a first portion of vitreous carbon cylindrically surrounding the axial bore, and a containment portion of vitreous carbon surrounds the radioisotope containing portion, the two portions of vitreous carbon being integrally formed as a single unit. Connecting means are provided at each end of the cylindrical body to permit connections to blood-carrying vessels and to provide for passage of blood through the bore. In a preferred embodiment, the radioisotope is thulium-170 which is present in the irradiator in the form of thulium oxide. A method of producing the preferred blood irradiator is also provided, whereby nonradioactive thulium-169 is dispersed within a polyfurfuryl alcohol resin which is carbonized and fired to form the integral vitreous carbon body and the device is activated by neutron bombardment of the thulium-169 to produce the beta-emitting thulium-170

  1. Blood irradiation

    International Nuclear Information System (INIS)

    Chandy, Mammen

    1998-01-01

    Viable lymphocytes are present in blood and cellular blood components used for transfusion. If the patient who receives a blood transfusion is immunocompetent these lymphocytes are destroyed immediately. However if the patient is immunodefficient or immunosuppressed the transfused lymphocytes survive, recognize the recipient as foreign and react producing a devastating and most often fatal syndrome of transfusion graft versus host disease [T-GVHD]. Even immunocompetent individuals can develop T-GVHD if the donor is a first degree relative since like the Trojan horse the transfused lymphocytes escape detection by the recipient's immune system, multiply and attack recipient tissues. T-GVHD can be prevented by irradiating the blood and different centers use doses ranging from 1.5 to 4.5 Gy. All transfusions where the donor is a first degree relative and transfusions to neonates, immunosuppressed patients and bone marrow transplant recipients need to be irradiated. Commercial irradiators specifically designed for irradiation of blood and cellular blood components are available: however they are expensive. India needs to have blood irradiation facilities available in all large tertiary institutions where immunosuppressed patients are treated. The Atomic Energy Commission of India needs to develop a blood irradiator which meets international standards for use in tertiary medical institutions in the country. (author)

  2. Food irradiation

    International Nuclear Information System (INIS)

    Migdal, W.

    1995-01-01

    A worldwide standard on food irradiation was adopted in 1983 by codex Alimentarius Commission of the Joint Food Standard Programme of the Food and Agriculture Organization (FAO) of the United Nations and The World Health Organization (WHO). As a result, 41 countries have approved the use of irradiation for treating one or more food items and the number is increasing. Generally, irradiation is used to: food loses, food spoilage, disinfestation, safety and hygiene. The number of countries which use irradiation for processing food for commercial purposes has been increasing steadily from 19 in 1987 to 33 today. In the frames of the national programme on the application of irradiation for food preservation and hygienization an experimental plant for electron beam processing has been established in Inst. of Nuclear Chemistry and Technology. The plant is equipped with a small research accelerator Pilot (19 MeV, 1 kW) and industrial unit Electronika (10 MeV, 10 kW). On the basis of the research there were performed at different scientific institutions in Poland, health authorities have issued permissions for irradiation for; spices, garlic, onions, mushrooms, potatoes, dry mushrooms and vegetables. (author)

  3. Food irradiation

    International Nuclear Information System (INIS)

    1991-01-01

    Processing of food with low levels of radiation has the potential to contribute to reducing both spoilage of food during storage - a particular problem in developing countries - and the high incidence of food-borne disease currently seen in all countries. Approval has been granted for the treatment of more than 30 products with radiation in over 30 countries but, in general, governments have been slow to authorize the use of this new technique. One reason for this slowness is a lack of understanding of what food irradiation entails. This book aims to increase understanding by providing information on the process of food irradiation in simple, non-technical language. It describes the effects that irradiation has on food, and the plant and equipment that are necessary to carry it out safely. The legislation and control mechanisms required to ensure the safety of food irradiation facilities are also discussed. Education is seen as the key to gaining the confidence of the consumers in the safety of irradiated food, and to promoting understanding of the benefits that irradiation can provide. (orig.) With 4 figs., 1 tab [de

  4. The effect of different dopant concentration of tailor-made silica fibers in radiotherapy dosimetry

    Science.gov (United States)

    Begum, Mahfuza; Mizanur Rahman, A. K. M.; Zubair, H. T.; Abdul-Rashid, H. A.; Yusoff, Z.; Begum, Mahbuba; Alkhorayef, M.; Alzimami, K.; Bradley, D. A.

    2017-12-01

    In thermoluminescence (TL) material dopant concentration has an important effect on their characteristics as a ;radiation-sensor;. The study investigates dosimetric properties of four different concentration (4 mol%, 5 mol%, 7 mol% and 25 mol%) tailor-made Ge-doped silica fibers. The intention is to seek development of alternative TL materials that offer exceptional advantages over existing passive systems of dosimetry, including improved spatial resolution, a water impervious nature and low cost. Photon beams (6 MV and 10 MV) from a clinical linear accelerator were used for irradiation of the fiber samples over radiation therapy doses, ranging from 0.5 Gy to 8 Gy. SEM-EDX analysis was also performed to investigate the homogeneity of distribution of Ge dopant concentration from the fiber samples. The results of measurement were also compared with two of the more commonly used standard TLDs, TLD-100 (LiF: Mg,Ti-7.5% 6LiF) and TLD-700 ((7LiF: Mg,Ti-99.9%7LiF) chips respectively. The TL intensity of the fiber samples was found to strongly depend on Ge dopant concentration, with samples showing enhanced TL yields with decreasing Ge dopant concentration. 4 mol% Ge-doped silica fiber provided the greatest response whereas the 25 mol% samples showed the least, indicative of the well-known concentration quenching effects All fiber TLDs provided linear dose response over the delivered radiotherapy dose-range, the fibers also showing a weak dependence on photon beam energies in comparing the TL yields at 6 and 10 MV. The fading behavior of the different concentration Ge doped TLD-materials were also measured over a period of thirty (30) days subsequent to irradiation. The relative sensitivity of the samples with respect to standard TLD-100 were found to be 0.37, 0.26, 0.13 and 0.02 in respect of the 4, 5, 7 and 25 mol% fibers. The primary dosimetry peak, which was by far the most prominent of any other feature covered by the glow curve, was found to be around 244 °C using

  5. Estimation of DNA DSB radiation damage using a solid state nanodosimeters based on glow peak 5a in LiF:Mg,Ti (TLD-100)

    International Nuclear Information System (INIS)

    Oster, L.; Haddad, J.; Horowitz, Y.S.; Biderman, S.

    2002-01-01

    We demonstrate the viability of the concept of using existing molecular nano structures in TL solid-state nanodosimeters. The concept is based on mimicking radiobiology (specifically the ionization density dependence of double strand breaks in DNA) by using the similar ionization density dependence of simultaneous electron-hole capture in spatially correlated TC/LC pairs in the thermoluminescence of LiF:Mg, Ti. This simultaneous electron-hole capture has been shown to lead to ionization density dependence in the relative intensity of peak 5a to peak 5 similar to the ratio of DSBs to SSBs for low energy He ions. (authors)

  6. MALDI-TOF MS and CE-LIF Fingerprinting of Plant Cell Wall Polysaccharide Digests as a Screening Tool for Arabidopsis Cell Wall Mutants

    NARCIS (Netherlands)

    Westphal, Y.; Schols, H.A.; Voragen, A.G.J.; Gruppen, H.

    2010-01-01

    Cell wall materials derived from leaves and hypocotyls of Arabidopsis mutant and wild type plants have been incubated with a mixture of pure and well-defined pectinases, hemicellulases, and cellulases. The resulting oligosaccharides have been subjected to MALDI-TOF MS and CE-LIF analysis. MALDI-TOF

  7. Establishment of LIF-dependent human iPS cells closely related to basic FGF-dependent authentic iPS cells.

    Directory of Open Access Journals (Sweden)

    Hiroyuki Hirai

    Full Text Available Human induced pluripotent stem cells (iPSCs can be divided into a leukemia inhibitory factor (LIF-dependent naïve type and a basic fibroblast growth factor (bFGF-dependent primed type. Although the former are more undifferentiated than the latter, they require signal transduction inhibitors and sustained expression of the transgenes used for iPSC production. We used a transcriptionally enhanced version of OCT4 to establish LIF-dependent human iPSCs without the use of inhibitors and sustained transgene expression. These cells belong to the primed type of pluripotent stem cell, similar to bFGF-dependent iPSCs. Thus, the particular cytokine required for iPSC production does not necessarily define stem cell phenotypes as previously thought. It is likely that the bFGF and LIF signaling pathways converge on unidentified OCT4 target genes. These findings suggest that our LIF-dependent human iPSCs could provide a novel model to investigate the role of cytokine signaling in cellular reprogramming.

  8. New Method Based on Capillary Electrophoresis with Laser-Induced Fluorescence Detection (CE-LIF) to Monitor Interaction between Nanoparticles and the Amyloid-β Peptide

    NARCIS (Netherlands)

    Brambilla, Davide; Verpillot, Romain; Taverna, Myriam; de Kimpe, Line; Le Droumaguet, Benjamin; Nicolas, Julien; Canovi, Mara; Gobbi, Marco; Mantegazza, Francesco; Salmona, Mario; Nicolas, Valérie; Scheper, Wiep; Couvreur, Patrick; Andrieux, Karine

    2010-01-01

    A novel application of capillary electrophoresis with laser-induced fluorescence detection (CE-LIF) was proposed to efficiently detect and monitor the interaction between polymeric nanoparticles and the β-Amyloid peptide (Aβ(1-42)), a biomarker for Alzheimer's Disease (AD), at concentrations close

  9. Electronic structure optical spectra and contact hyperfine parameters of CoF64- complex in LiF and KMgF3

    International Nuclear Information System (INIS)

    Albuquerque, E.L. de.

    1975-12-01

    The electronic structure, the optical absorption bands and the magnetic hyperfine contact terms have been calculated for CoF 6 4- cluster in LiF and KMgF 3 using the Self-Consistent-Field Multiple-Scattering Xα Method. The results obtained are compared with experiment and indicate that this scheme is convenient to treat such complex problems. (Author) [pt

  10. Validation and dosimetric evaluation employing the techniques of TL and OSL of thermoluminescent materials for application in the dosimetry of clinical beams of electrons used in total irradiation of the skin - TSI; Validação e avaliação dosimétrica empregando as técnicas de TL e OSL de materiais termoluminescentes para aplicação na dosimetria de feixes clínicos de elétrons utilizados na irradiação total da pele

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, Shirlane Barbosa de

    2017-07-01

    In vivo dosimetry has become an important role for the treatment of total skin irradiation within a rigorous quality assurance program that should be an integral part of the radiotherapy departments. TSI dosimetry is difficult because of the complexity of the treatment in assessing dose uniformity and measuring the dose absorbed at shallow depths throughout the skin surface extent, resulting in a wide variation in dose distribution. The TLDs have proven to be very useful for the distribution and verification of the dose prescribed for the patient as the dose may differ from place to place due to patient body geometry, overlapping of structures and asymmetries of the radiation field. The use of TLDs in vivo can identify variations in the prescribed dose because its measurement accuracy and great precision. Several types of dosimeters have been used in the radiotherapy sectors, the most commonly used are Lithium Fluride (TLD-100), where it obtains a long history in this type of application. New dosimetric materials have gained great importance in the dosimetry of clinical electron beams, such as Dysprosium-doped Calcium Sulphate (TL) and Carbon doped (OSL) based Aluminum Oxide, This work evaluates the performance of the respective thermoluminescent dosimeters and the optically stimulated luminescence in the dosimetry of clinical electron beams used in total irradiation of the skin. (author)

  11. Irradiation device

    International Nuclear Information System (INIS)

    Suzuki, Toshimitsu.

    1989-01-01

    In an irradiation device for irradiating radiation rays such as electron beams to pharmaceuticals, etc., since the distribution of scanned electron rays was not monitored, the electron beam intensity could be determined only indirectly and irradiation reliability was not satisfactory. In view of the above, a plurality of monitor wires emitting secondary electrons are disposed in the scanning direction near a beam take-out window of a scanning duct, signals from the monitor wires are inputted into a display device such as a cathode ray tube, as well as signals from the monitor wires at the central portion are inputted into counting rate meters to measure the radiation dose as well. Since secondary electrons are emitted when electron beams pass through the monitor wires and the intensity thereof is in proportion with the intensity of incident electron beams, the distribution of the radiation dose can be monitored by measuring the intensity of the emitted secondary electrons. Further, uneven irradiation, etc. can also be monitored to make the radiation of irradiation rays reliable. (N.H.)

  12. Transport properties of LiF under strong compression: modeling using advanced electronic structure methods and classical molecular dynamics

    Science.gov (United States)

    Mattsson, Thomas R.; Jones, Reese; Ward, Donald; Spataru, Catalin; Shulenburger, Luke; Benedict, Lorin X.

    2015-06-01

    Window materials are ubiquitous in shock physics and with high energy density drivers capable of reaching multi-Mbar pressures the use of LiF is increasing. Velocimetry and temperature measurements of a sample through a window are both influenced by the assumed index of refraction and thermal conductivity, respectively. We report on calculations of index of refraction using the many-body theory GW and thermal ionic conductivity using linear response theory and model potentials. The results are expected to increase the accuracy of a broad range of high-pressure shock- and ramp compression experiments. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Company, for the U.S. Department of Energy's National Nuclear Security Administration under Contract DE-AC04-94AL85000.

  13. TR-LIF LIFETIME MEASUREMENTS AND HFR+CPOL CALCULATIONS OF RADIATIVE PARAMETERS IN VANADIUM ATOM (V I)

    International Nuclear Information System (INIS)

    Wang, Q.; Jiang, L. Y.; Shang, X.; Tian, Y. S.; Dai, Z. W.; Quinet, P.; Palmeri, P.; Zhang, W.

    2014-01-01

    Radiative lifetimes of 79 levels belonging to the 3d 3 4s4p, 3d 4 4p, 3d 3 4s5p, 3d 4 5p, and 3d 3 4s4d configurations of V I with energy from 26,604.807 to 46,862.786 cm –1 have been measured using time-resolved laser-induced fluorescence (TR-LIF) spectroscopy in laser-produced plasma. The lifetime values reported in this paper are in the range of 3.3-494 ns, and the uncertainties of these measurements are within ±10%. A good agreement was obtained with previous data. HFR+CPOL calculations have been performed and used to combine the calculated branching fractions with the available experimental lifetimes to determine semi-empirical transition probabilities for 784 V I transitions

  14. Spike Pattern Structure Influences Synaptic Efficacy Variability Under STDP and Synaptic Homeostasis. II: Spike Shuffling Methods on LIF Networks

    Directory of Open Access Journals (Sweden)

    Zedong Bi

    2016-08-01

    Full Text Available Synapses may undergo variable changes during plasticity because of the variability of spike patterns such as temporal stochasticity and spatial randomness. Here, we call the variability of synaptic weight changes during plasticity to be efficacy variability. In this paper, we investigate how four aspects of spike pattern statistics (i.e., synchronous firing, burstiness/regularity, heterogeneity of rates and heterogeneity of cross-correlations influence the efficacy variability under pair-wise additive spike-timing dependent plasticity (STDP and synaptic homeostasis (the mean strength of plastic synapses into a neuron is bounded, by implementing spike shuffling methods onto spike patterns self-organized by a network of excitatory and inhibitory leaky integrate-and-fire (LIF neurons. With the increase of the decay time scale of the inhibitory synaptic currents, the LIF network undergoes a transition from asynchronous state to weak synchronous state and then to synchronous bursting state. We first shuffle these spike patterns using a variety of methods, each designed to evidently change a specific pattern statistics; and then investigate the change of efficacy variability of the synapses under STDP and synaptic homeostasis, when the neurons in the network fire according to the spike patterns before and after being treated by a shuffling method. In this way, we can understand how the change of pattern statistics may cause the change of efficacy variability. Our results are consistent with those of our previous study which implements spike-generating models on converging motifs. We also find that burstiness/regularity is important to determine the efficacy variability under asynchronous states, while heterogeneity of cross-correlations is the main factor to cause efficacy variability when the network moves into synchronous bursting states (the states observed in epilepsy.

  15. 6LiF sandwich type detectors for low dose individual monitoring in mixed neutron-photon fields

    International Nuclear Information System (INIS)

    Olko, P.; Budzanowski, M.; Bilski, P.; Burgkhardt, B.; Piesch, E.

    1994-01-01

    ICRP Publication 60 recommends the reduction of the annual dose limit for occupational exposure from 50 to 20 mSv and a doubling of the quality factor for medium energy neutrons. If occupational doses are evaluated every month (which is obligatory e.g. in Germany and in Poland), the individual neutron dosemeter will have to measure neutron doses in the range of 100 μSv. No commercially available, automatic individual dosimetry monitoring system exists that fulfils this requirement. Some of the parameters which influence the evaluation of the neutron dose from readings of TL dosemeters have been studied in order to decrease the variance of the measured neutron signal. In mixed neutron-photon fields, clear separation of the neutron component from the total reading depends also on the uncertainty of the gamma dose measurements. While the thermal albedo neutrons are absorbed mostly at the surface of the 6 LiF detector, the reduction of the detector thickness results in a decrease of its photon sensitivity, while its neutron sensitivity is almost principally maintained. As a consequence, the uncertainty of gamma dose contributes with lower weight to the variance of the evaluated neutron signal. First tests of an optimised 200 μm thick sandwich detector and 0.9 mm thick standard LiF chips were made at low neutron and photon dose ranges using different readers, in order to determine the uncertainty versus dose for different neutron-photon combinations. The conditions under which the new sandwich type detectors may improve albedo neutron dosimetry are demonstrated. (Author)

  16. Food irradiation

    International Nuclear Information System (INIS)

    Beishon, J.

    1991-01-01

    Food irradiation has been the subject of concern and controversy for many years. The advantages of food irradiation include the reduction or elimination of dangerous bacterial organisms, the control of pests and insects which destroy certain foods, the extension of the shelf-life of many products, for example fruit, and its ability to treat products such as seafood which may be eaten raw. It can also replace existing methods of treatment which are believed to have hazardous side-effects. However, after examining the evidence produced by the proponents of food irradiation, the author questions whether it has any major contribution to make to the problems of foodborne diseases or world food shortages. More acceptable solutions, he suggests, may be found in educating food handlers to ensure that hygienic conditions prevail in the production, storage and serving of food. (author)

  17. Vinca irradiator

    International Nuclear Information System (INIS)

    Eymery, R.

    1976-10-01

    The development programme of the VINCA radiosterilisation centre involves plans for an irradiator capable of working in several ways. Discontinuous operation. The irradiator is loaded for a certain period then runs automatically until the moment of unloading. This method is suitable as long as the treatment capacity is relatively small. Continuous operation with permanent batch loading and unloading carried out either manually or automatically (by means of equipment to be installed later). Otherwise the design of the apparatus is highly conventional. The source is a vertical panel submersible in a pool. The conveyor is of the 'bucket' type, with 4 tiers to each bucket. The batches pass successively through all possible irradiation positions. Transfert into and out of the cell take place through a maze, which also provides access to the cell when the sources are in storage at the bottom of the pool [fr

  18. Irradiance gradients

    International Nuclear Information System (INIS)

    Ward, G.J.; Heckbert, P.S.; Technische Hogeschool Delft

    1992-04-01

    A new method for improving the accuracy of a diffuse interreflection calculation is introduced in a ray tracing context. The information from a hemispherical sampling of the luminous environment is interpreted in a new way to predict the change in irradiance as a function of position and surface orientation. The additional computation involved is modest and the benefit is substantial. An improved interpolation of irradiance resulting from the gradient calculation produces smoother, more accurate renderings. This result is achieved through better utilization of ray samples rather than additional samples or alternate sampling strategies. Thus, the technique is applicable to a variety of global illumination algorithms that use hemicubes or Monte Carlo sampling techniques

  19. Irradiation damage to the gonads caused by radiotherapy of benign diseases. Pt. 2

    International Nuclear Information System (INIS)

    Hassenstein, E.; Nuesslin, F.

    1976-01-01

    The irradiation damage to the gonads caused by the radiotherapy of parotiditis and mastitis and of cheloids was determined partially under different irradiation methods. The measurements were carried out with LiF dosimeters in the Alderson phantom with a tube tension of 250 kV for the inflammatory diseases and 55 kV for the cheloids. The gonad dose measured at the surface was within the range of hundreths of permille for the parotiditis, for the mastitis it was between tenths of permille and 2 0 / 00 depending on the therapy method. The gonad dose of the cheloid irradiations showed a clear relation to the distance between radiation source and gonads. The importance of radiation protection is emphasized. (orig.) [de

  20. ion irradiation

    Indian Academy of Sciences (India)

    Swift heavy ions interact predominantly through inelastic scattering while traversing any polymer medium and produce excited/ionized atoms. Here samples of the polycarbonate Makrofol of approximate thickness 20 m, spin coated on GaAs substrate were irradiated with 50 MeV Li ion (+3 charge state). Build-in ...

  1. Fish irradiation

    International Nuclear Information System (INIS)

    Kovacs, J.; Tengumnuay, C.; Juangbhanich, C.

    1970-01-01

    Chub-mackerel was chosen for the study because they are the most common fish in Thailand. Preliminary investigations were conducted to determine the maximum radiation dose of gamma-rays by organoleptic tests. The samples were subjected to radiation at various doses up to 4 Mrad. Many experiments were conducted using other kinds of fish. The results showed that 1 Mrad would be the maximum acceptable dose for fish. Later, the influence of the radiation dose from 0.1-1 Mrad was studied in order to find the optimum acceptable dose for preservation of fish without off-flavour. For this purpose, the Hedonic scale was used. It was found that 0.2 and 0.5 Mrad gave the best result on Chub mackerel. The determinations of optimum dose, organoleptic, microbiological and trimethylamine content changes were done. The results showed that Chub mackerel irradiated at 0.2, 0.5 and 1 Mrad stored at 3 0 C for 71 days were still acceptable, on the contrary the untreated samples were found unacceptable at 14 days. The trimethylamine increment was significantly higher in the untreated samples. At 15 days storage, trimethylamine in the non-irradiated Chub-mackerel was about 10 times higher than the irradiated ones. At 51 and 79 days storage, about 13 times higher in the control samples than the irradiated samples except 0.1 Mrad. Only 2 times higher was found for the 0.1 Mrad. The microbiological results showed that the irradiation above 0.2 Mrad gave favorable extension of shelf-life of fish

  2. Chapter 2: Irradiators

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2018-04-01

    The chapter 2 presents the subjects: 1) gamma irradiators which includes: Category-I gamma irradiators (self-contained); Category-II gamma irradiators (panoramic and dry storage); Category-III gamma irradiators (self-contained in water); Category-IV gamma irradiators (panoramic and wet storage); source rack for Category-IV gamma irradiators; product transport system for Category-IV gamma irradiators; radiation shield for gamma irradiators; 2) accelerators which includes: Category-I Accelerators (shielded irradiator); Category-II Accelerators (irradiator inside a shielded room); Irradiation application examples.

  3. Food irradiation: An update

    International Nuclear Information System (INIS)

    Morrison, Rosanna M.

    1984-01-01

    Recent regulatory and commercial activity regarding food irradiation is highlighted. The effects of irradiation, used to kill insects and microorganisms which cause food spoilage, are discussed. Special attention is given to the current regulatory status of food irradiation in the USA; proposed FDA regulation regarding the use of irradiation; pending irradiation legislation in the US Congress; and industrial applications of irradiation

  4. Industrial irradiation

    International Nuclear Information System (INIS)

    Stirling, Andrew

    1995-01-01

    Production lines for rubber gloves would not appear to have much in common with particle physics laboratories, but they both use accelerators. Electron beam irradiation is often used in industry to improve the quality of manufactured goods or to reduce production cost. Products range from computer disks, shrink packaging, tyres, cables, and plastics to hot water pipes. Some products, such as medical goods, cosmetics and certain foodstuffs, are sterilized in this way. In electron beam irradiation, electrons penetrate materials creating showers of low energy electrons. After many collisions these electrons have the correct energy to create chemically active sites. They may either break molecular bonds or activate a site which promotes a new chemical linkage. This industrial irradiation can be exploited in three ways: breaking down a biological molecule usually renders it useless and kills the organism; breaking an organic molecule can change its toxicity or function; and crosslinking a polymer can strengthen it. In addition to traditional gamma irradiation using isotopes, industrial irradiation uses three accelerator configurations, each type defining an energy range, and consequently the electron penetration depth. For energies up to 750 kV, the accelerator consists of a DC potential applied to a simple wire anode and the electrons extracted through a slot in a coaxially mounted cylindrical cathode. In the 1-5 MeV range, the Cockcroft-Walton or Dynamitron( R ) accelerators are normally used. To achieve the high potentials in these DC accelerators, insulating SF6 gas and large dimension vessels separate the anode and cathode; proprietary techniques distinguish the various commercial models available. Above 5 MeV, the size of DC accelerators render them impractical, and more compact radiofrequency-driven linear accelerators are used. Irradiation electron beams are actually 'sprayed' over the product using a magnetic deflection system. Lower energy beams of

  5. Comparison of OH concentration measurements by DOAS and LIF during SAPHIR chamber experiments at high OH reactivity and low NO concentration

    Directory of Open Access Journals (Sweden)

    H. Fuchs

    2012-07-01

    Full Text Available During recent field campaigns, hydroxyl radical (OH concentrations that were measured by laser-induced fluorescence (LIF were up to a factor of ten larger than predicted by current chemical models for conditions of high OH reactivity and low NO concentration. These discrepancies, which were observed in forests and urban-influenced rural environments, are so far not entirely understood. In summer 2011, a series of experiments was carried out in the atmosphere simulation chamber SAPHIR in Jülich, Germany, in order to investigate the photochemical degradation of isoprene, methyl-vinyl ketone (MVK, methacrolein (MACR and aromatic compounds by OH. Conditions were similar to those experienced during the PRIDE-PRD2006 campaign in the Pearl River Delta (PRD, China, in 2006, where a large difference between OH measurements and model predictions was found. During experiments in SAPHIR, OH was simultaneously detected by two independent instruments: LIF and differential optical absorption spectroscopy (DOAS. Because DOAS is an inherently calibration-free technique, DOAS measurements are regarded as a reference standard. The comparison of the two techniques was used to investigate potential artifacts in the LIF measurements for PRD-like conditions of OH reactivities of 10 to 30 s−1 and NO mixing ratios of 0.1 to 0.3 ppbv. The analysis of twenty experiment days shows good agreement. The linear regression of the combined data set (averaged to the DOAS time resolution, 2495 data points yields a slope of 1.02 ± 0.01 with an intercept of (0.10 ± 0.03 × 106 cm−3 and a linear correlation coefficient of R2 = 0.86. This indicates that the sensitivity of the LIF instrument is well-defined by its calibration procedure. No hints for artifacts are observed for isoprene, MACR, and different aromatic compounds. LIF measurements were approximately 30–40% (median larger than those by DOAS after MVK (20 ppbv and

  6. Food irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Beerens, H [Lille-1 Univ., 59 - Villeneuve-d' Ascq (France); Saint-Lebe, L

    1979-01-01

    Various aspects of food treatment by cobalt 60 or caesium 137 gamma radiation are reviewed. One of the main applications of irradiation on foodstuffs lies in its ability to kill micro-organisms, lethal doses being all the lower as the organism concerned is more complex. The effect on parasites is also spectacular. Doses of 200 to 300 krad are recommended to destroy all parasites with no survival period and no resistance phenomenon has ever been observed. The action of gamma radiation on macromolecules was also investigated, the bactericide treatment giving rise to side effects by transformation of food components. Three examples were studied: starch, nucleic acids and a whole food, the egg. The organoleptic aspect of irradiation was examined for different treated foods, then the physical transformations of unpasteurized, heat-pasteurized and radio-pasteurized eggs were compared. The report ends with a brief analysis of the toxicity and conditions of application of the treatment.

  7. Irradiation device

    International Nuclear Information System (INIS)

    Ransohoff, J.A.

    1984-01-01

    Carriers, after being loaded with product to be irradiated, are transported by an input-output conveyor system into an irradiation chamber where they are received in a horizontal arrangement on racks which may support different sizes and numbers of carriers. The racks are moved by a chamber conveyor system in an endless rectangular path about a radiation source. Packers shift the carriers on the racks to maintain nearest proximity to the radiation source. The carriers are shifted in position on each rack during successive rack cycles to produce even radiation exposure. The carriers may be loaded singly onto successive racks during a first cycle of movement thereof about the source, with loading of additional carriers, and/or unloading of carriers, onto each rack occurring on subsequent rack cycles of movement

  8. Food irradiation

    International Nuclear Information System (INIS)

    Roberts, P.B.

    1997-01-01

    Food can be provided with extra beneficial properties by physical processing. These benefits include a reduced possibility of food poisoning, or an increased life of the food. We are familiar with pasteurisation of milk, drying of vegetables, and canning of fruit. These physical processes work because the food absorbs energy during treatment which brings about the changes needed. The energy absorbed in these examples is heat energy. Food irradiation is a less familiar process. It produces similar benefits to other processes and it can sometimes be applied with additional advantages over conventional processing. For example, because irradiation causes little heating, foods may look and taste more natural. Also, treatment can take place with the food in its final plastic wrappers, reducing the risk of re-contamination. (author). 1 ref., 4 figs., 1 tab

  9. Food irradiation

    International Nuclear Information System (INIS)

    Beerens, H.; Saint-Lebe, L.

    1979-01-01

    Various aspects of food treatment by cobalt 60 or caesium 137 gamma radiation are reviewed. One of the main applications of irradiation on foodstuffs lies in its ability to kill micro-organisms, lethal doses being all the lower as the organism concerned is more complex. The effect on parasites is also spectacular. Doses of 200 to 300 krad are recommended to destroy all parasites with no survival period and no resistance phenomenon has ever been observed. The action of gamma radiation on macromolecules was also investigated, the bactericide treatment giving rise to side effects by transformation of food components. Three examples were studied: starch, nucleic acids and a whole food, the egg. The organoleptic aspect of irradiation was examined for different treated foods, then the physical transformations of unpasteurized, heat-pasteurized and radio-pasteurized eggs were compared. The report ends with a brief analysis of the toxicity and conditions of application of the treatment [fr

  10. Endolymphatic irradiation

    International Nuclear Information System (INIS)

    Galvao, M.M.; Ianhez, L.E.; Sabbaga, E.

    1982-01-01

    The authors analysed the clinical evolution and the result of renal transplantation some years after irradiation in 24 patients (group I) who received endolymphatic 131 I as a pre-transplantation immunesuppresive measure. The control group (group II) consisted of 24 non-irradiated patients comparable to group I in age, sex, primary disease, type of donor and immunesuppressive therapy. Significant differences were observed between the two groups regarding such factors a incidence and reversibility of rejection crises in the first 60 post-transplantation days, loss of kidney due to rejection, and dosage of azathioprine. The authors conclude that this method, besides being harmless, has prolonged immunesuppressive action, its administration being advised for receptores of cadaver kidneys, mainly those who show positive cross-match against HLA antigens for painel. (Author) [pt

  11. Application of Glow Curve Deconvolution Method to Evaluate Low Dose TLD LiF

    International Nuclear Information System (INIS)

    Kurnia, E; Oetami, H R; Mutiah

    1996-01-01

    Thermoluminescence Dosimeter (TLD), especially LiF:Mg, Ti material, is one of the most practical personal dosimeter in known to date. Dose measurement under 100 uGy using TLD reader is very difficult in high precision level. The software application is used to improve the precision of the TLD reader. The objectives of the research is to compare three Tl-glow curve analysis method irradiated in the range between 5 up to 250 uGy. The first method is manual analysis, dose information is obtained from the area under the glow curve between pre selected temperature limits, and background signal is estimated by a second readout following the first readout. The second method is deconvolution method, separating glow curve into four peaks mathematically and dose information is obtained from area of peak 5, and background signal is eliminated computationally. The third method is deconvolution method but the dose is represented by the sum of area of peak 3,4 and 5. The result shown that the sum of peak 3,4 and 5 method can improve reproducibility six times better than manual analysis for dose 20 uGy, the ability to reduce MMD until 10 uGy rather than 60 uGy with manual analysis or 20 uGy with peak 5 area method. In linearity, the sum of peak 3,4 and 5 method yields exactly linear dose response curve over the entire dose range

  12. Standard Practice for Use of a Lif Photo-Fluorescent Film Dosimetry System

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This practice covers the handling, testing, and procedure for using a lithium fluoride (LiF)-based photo-fluorescent film dosimetry system to measure absorbed dose (relative to water) in materials irradiated by photons or electrons. Other alkali halides that may also exhibit photofluorescence (for example, NaCl, NaF, and KCl) are not covered in this practice. Although various alkali halides have been used for dosimetry for years utilizing thermoluminescence, the use of photoluminescence is relatively new. 1.2 This practice applies to photo-fluorescent film dosimeters (referred hereafter as photo-fluorescent dosimeters) that can be used within part or all of the following ranges: 1.2.1 Absorbed dose range of 5 10-2 to 3 102 kGy (1-3). 1.2.2 Absorbed dose rate range of 0.3 to 2 10 4 Gy/s (2-5)). 1.2.3 Radiation energy range for photons of 0.05 to 10 MeV (2). 1.2.4 Radiation energy range for electrons of 0.1 to 10 MeV (2). 1.2.5 Radiation temperature range of -20 to +60°C (6,7). 1.3 This standard doe...

  13. Thermoluminescent dosimetry in computed tomography

    International Nuclear Information System (INIS)

    Lara C, A.; Rivera M, T.; Osorio V, M.; Hernandez O, O.

    2016-10-01

    In this work we studied the dosimetry performed on CT scan in two different equipment, SOMATOM and Phillips, with 16 and 64 slice respectively. We used 51 pellets of lithium fluoride doped with magnesium and titanium (LiF: Mg, Ti) also knows as TLD-100 due to its physical properties and its easy of use, in this study, first analysis a batch of 56 pellets, but only 53 pellets were optimal for this study, cesium-137 was used as source irradiation, then proceeded to calibrate the batch with X-rays source, measuring the corresponding dose in a Farmers ionization chamber, then, we obtained a calibration curve, and we used as reference to calculation of the applied dose, finally designing ergonomic mesh, were it was deposited a TLD 100, placed in a regions of interest were made to each scan type. Once characterized our material proceeded to testing in 30 patients, which were irradiated with X-ray tube, whose operation was performed at 80, 120 kV with a current of 100, 300 and 400 m A according to scanning protocol. Overall we measured dose of 5 mGy to 53 mGy, these measurements reflect significant dose to can induced cancer, due previous reports published, that doses greater than 20 mGy there is a risk of developing cancer in the long term, but in practice when it assigned a medical diagnosis, there are no dose limits due to benefits patients, however, IAEA publish recommendations that allow us to carry out optimum handling of ionizing radiation, among these is the quality control of the tomography equipment that helps greatly reduce patient dose. (Author)

  14. Thermoluminescent dosimetry in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lara C, A.; Rivera M, T. [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Unidad Legaria, Av. Legaria 694, Col. Irrigacion, 11500 Ciudad de Mexico (Mexico); Osorio V, M. [ISSSTE, Centro Medico Nacional 20 de Noviembre, Felix Cuevas 540, Col. del Valle, 03100 Ciudad de Mexico (Mexico); Hernandez O, O., E-mail: armando_lara_cam@yahoo.com.mx [Hospital General de Mexico, Dr. Balmis 148, Col. Doctores, 06726 Ciudad de Mexico (Mexico)

    2016-10-15

    In this work we studied the dosimetry performed on CT scan in two different equipment, SOMATOM and Phillips, with 16 and 64 slice respectively. We used 51 pellets of lithium fluoride doped with magnesium and titanium (LiF: Mg, Ti) also knows as TLD-100 due to its physical properties and its easy of use, in this study, first analysis a batch of 56 pellets, but only 53 pellets were optimal for this study, cesium-137 was used as source irradiation, then proceeded to calibrate the batch with X-rays source, measuring the corresponding dose in a Farmers ionization chamber, then, we obtained a calibration curve, and we used as reference to calculation of the applied dose, finally designing ergonomic mesh, were it was deposited a TLD 100, placed in a regions of interest were made to each scan type. Once characterized our material proceeded to testing in 30 patients, which were irradiated with X-ray tube, whose operation was performed at 80, 120 kV with a current of 100, 300 and 400 m A according to scanning protocol. Overall we measured dose of 5 mGy to 53 mGy, these measurements reflect significant dose to can induced cancer, due previous reports published, that doses greater than 20 mGy there is a risk of developing cancer in the long term, but in practice when it assigned a medical diagnosis, there are no dose limits due to benefits patients, however, IAEA publish recommendations that allow us to carry out optimum handling of ionizing radiation, among these is the quality control of the tomography equipment that helps greatly reduce patient dose. (Author)

  15. Evaluation of machine learning algorithms for classification of primary biological aerosol using a new UV-LIF spectrometer

    Science.gov (United States)

    Ruske, Simon; Topping, David O.; Foot, Virginia E.; Kaye, Paul H.; Stanley, Warren R.; Crawford, Ian; Morse, Andrew P.; Gallagher, Martin W.

    2017-03-01

    Characterisation of bioaerosols has important implications within environment and public health sectors. Recent developments in ultraviolet light-induced fluorescence (UV-LIF) detectors such as the Wideband Integrated Bioaerosol Spectrometer (WIBS) and the newly introduced Multiparameter Bioaerosol Spectrometer (MBS) have allowed for the real-time collection of fluorescence, size and morphology measurements for the purpose of discriminating between bacteria, fungal spores and pollen.This new generation of instruments has enabled ever larger data sets to be compiled with the aim of studying more complex environments. In real world data sets, particularly those from an urban environment, the population may be dominated by non-biological fluorescent interferents, bringing into question the accuracy of measurements of quantities such as concentrations. It is therefore imperative that we validate the performance of different algorithms which can be used for the task of classification.For unsupervised learning we tested hierarchical agglomerative clustering with various different linkages. For supervised learning, 11 methods were tested, including decision trees, ensemble methods (random forests, gradient boosting and AdaBoost), two implementations for support vector machines (libsvm and liblinear) and Gaussian methods (Gaussian naïve Bayesian, quadratic and linear discriminant analysis, the k-nearest neighbours algorithm and artificial neural networks).The methods were applied to two different data sets produced using the new MBS, which provides multichannel UV-LIF fluorescence signatures for single airborne biological particles. The first data set contained mixed PSLs and the second contained a variety of laboratory-generated aerosol.Clustering in general performs slightly worse than the supervised learning methods, correctly classifying, at best, only 67. 6 and 91. 1 % for the two data sets respectively. For supervised learning the gradient boosting algorithm was

  16. Measurement of surface phonon dispersion relations for LiF, NaF, and KCl through energy-analysed inelastic scattering of a helium atomic beam

    International Nuclear Information System (INIS)

    Doak, R.B.

    1981-01-01

    A crystal surface terminates abruptly one dimension of lattice periodicity, constituting a lattice defect with concomitant localized modes of vibration, termed surface phonons. Such surface phonons have previously been investigated in the long wavelength, non-dispersive regime. The present work reports the first observation of surface phonons in the short wavelength, dispersive range. The data allow for the first time a surface phonon dispersion curve to be plotted completely from origin to edge of the surface Brillouin zone. Measurements were made of phonons along the (anti GAMMA anti M) and (anti GAMMA anti X) azimuths of the LiF(001) surface and along the azimuth of NaF(001) and KC1(001) surfaces. The results are in substantial agreement with theoretical predictions, although for LiF the measured Rayleigh dispersion curve at M lies appreciably below the theoretical value, possibly reflecting the effects of surface relaxation. (orig.)

  17. Some features and results of thermal neutron background measurements with the [ZnS(Ag)+{sup 6}LiF] scintillation detector

    Energy Technology Data Exchange (ETDEWEB)

    Kuzminov, V.V.; Alekseenko, V.V.; Barabanov, I.R.; Etezov, R.A.; Gangapshev, A.M.; Gavrilyuk, Yu.M.; Gezhaev, A.M.; Kazalov, V.V. [Institute for Nuclear Research, 117312 Moscow (Russian Federation); Khokonov, A.Kh. [Kh.M. Berbekov Kabardino-Balkarian State University, 360004 (Russian Federation); Panasenko, S.I. [V.N. Karazin Kharkiv National University, 61022 Kharkiv (Ukraine); Ratkevich, S.S., E-mail: ssratk@gmail.com [V.N. Karazin Kharkiv National University, 61022 Kharkiv (Ukraine)

    2017-01-01

    Features of a thermal neutron test detector with thin scintillator [ZnS(Ag)+{sup 6}LiF] are described. Background of the detector and its registration efficiency were defined as a result of measurements. The thermal neutron flux at different locations, and for different conditions around the Baksan Neutrino Observatory are reported. - Highlights: • This paper describes tests of a thermal neutron detector based on a thin scintillator ZnS(Ag) with {sup 6}LiF. • The results are a measurement of the background neutron flux from the detector and the detector's efficiency. • The thermal neutron flux at different locations, and for different conditions around the Baksan Neutrino Observatory are reported.

  18. Electric conductivity of low-temperature molten electrolyte KF-AlF3 with additions of LiF and Al2O3

    International Nuclear Information System (INIS)

    Apisarov, A.P.; Kryukovskij, V.A.; Zajkov, Yu.P.; Red'kin, A.A.; Tkacheva, O.Yu.; Khokhlov, V.A.

    2007-01-01

    Electric conductivity of LiF, Al 2 O 3 doped KF-AlF 3 (Cryolite Ratio CR=1.3) molten electrolytes was estimated on the basis of empiric equations. Specific electric conductivity of KF-AlF 3 , KF-AIF 3 -AI 2 O 3 , KF-AlF 3 -LiF, KF-AlF 3 -LiF-Al 2 0 3 molten mixtures was measured in the range 687-797 Deg C. Cells with the pyrolytic boron nitride capillary and parallel molybdena electrodes were applied for the determination of electric conductivity. Comparison of calculated and experimental data of the specific electric conductivity of cryolite-alumina melts confirms that the offered model of the calculation adequate represents temperature and concentration dependencies, and it permits forecasting its change under the introduction of different additives in electrolyte [ru

  19. Direct measuring of single-cycle mid-IR light bullets path length in LiF by the laser coloration method

    Directory of Open Access Journals (Sweden)

    Chekalin Sergey

    2017-01-01

    Full Text Available A colour-centre structure formed in a LiF crystal under filamentation of a femtosecond mid-IR laser pulse with a power slightly exceeding the critical power for self-focusing has been experimentally and theoretically investigated. A single-cycle light bullet was recorded for the first time by observation of strictly periodic oscillations for the density of the color centers induced in an isotropic LiF crystal under filamentation of a laser beam with a wavelength tuned in the range from 2600 to 3900 nm, which is due to the periodic change in the light field amplitude in the light bullet formed under filamentation under propagation in dispersive medium. The light bullet path length was not more than one millimeter.

  20. Synthesis of plutonium trifluoride by hydro-fluorination and novel thermodynamic data for the PuF3-LiF system

    Science.gov (United States)

    Tosolin, A.; Souček, P.; Beneš, O.; Vigier, J.-F.; Luzzi, L.; Konings, R. J. M.

    2018-05-01

    PuF3 was synthetized by hydro-fluorination of PuO2 and subsequent reduction of the product by hydrogenation. The obtained PuF3 was analysed by X-Ray Diffraction (XRD) and found phase-pure. High purity was also confirmed by the melting point analysis using Differential Scanning Calorimetry (DSC). PuF3 was then used for thermodynamic assessment of the PuF3-LiF system. Phase equilibrium points and enthalpy of fusion of the eutectic composition were measured by DSC. XRD analyses of selected samples after DSC measurement confirm that after solidification from the liquid, the system returns to a mixture of LiF and PuF3.

  1. α6β1- and αV-integrins are required for long-term self-renewal of murine embryonic stem cells in the absence of LIF.

    Science.gov (United States)

    Cattavarayane, Sandhanakrishnan; Palovuori, Riitta; Tanjore Ramanathan, Jayendrakishore; Manninen, Aki

    2015-02-27

    The growth properties and self-renewal capacity of embryonic stem (ES) cells are regulated by their immediate microenvironment such as the extracellular matrix (ECM). Integrins, a central family of cellular ECM receptors, have been implicated in these processes but their specific role in ES cell self-renewal remains unclear. Here we have studied the effects of different ECM substrates and integrins in mouse ES cells in the absence of Leukemia Inhibitory Factor (LIF) using short-term assays as well as long-term cultures. Removal of LIF from ES cell culture medium induced morphological differentiation of ES cells into polarized epistem cell-like cells. These cells maintained epithelial morphology and expression of key stemness markers for at least 10 passages in the absence of LIF when cultured on laminin, fibronectin or collagen IV substrates. The specific functional roles of α6-, αV- and β1-integrin subunits were dissected using stable lentivirus-mediated RNAi methodology. β1-integrins were required for ES cell survival in long-term cultures and for the maintenance of stem cell marker expression. Inhibition of α6-integrin expression compromised self-renewal on collagen while αV-integrins were required for robust ES cell adhesion on laminin. Analysis of the stemness marker expression revealed subtle differences between α6- and αV-depleted ES cells but the expression of both was required for optimal self-renewal in long-term ES cell cultures. In the absence of LIF, long-term ES cell cultures adapt an epistem cell-like epithelial phenotype and retain the expression of multiple stem cell markers. Long-term maintenance of such self-renewing cultures depends on the expression of β1-, α6- and αV-integrins.

  2. Development of antireflection coatings with a sup 6 LiF/ sup 6 sup 2 Ni multilayer converter for ultracold neutron detectors

    CERN Document Server

    Maier-Komor, P; Bergmaier, A; Dollinger, G; Paul, S; Schott, W

    2002-01-01

    High efficiency detectors for ultracold neutrons (UCN) are needed at the new high flux neutron source, Forschungsreaktor Muenchen II. In the development described, silicon PIN diodes were chosen to detect the alpha-particles or the tritons created in the reaction sup 6 Li(n,alpha)t. The high reflectance of UCN on sup 6 Li with its positive optical potential must be compensated by a material with negative optical potential. The isotope sup 6 sup 2 Ni was chosen for this. To avoid problems due to chemical reactions of Li with humidity, the compound sup 6 LiF was chosen. One hundred and fifty double layers of sup 6 LiF/ sup 6 sup 2 Ni had to be deposited by physical vapor deposition on silicon PIN diodes which had already been coated with 88 nm approx 77 mu g/cm sup 2 of sup 5 sup 8 Ni for reflection of the UCN. The theoretical optimal thickness of the sup 6 sup 2 Ni layers is 3 nm, and that of sup 6 LiF is 6 nm. Since expensive isotopes were involved, a small source-to-substrate distance had to be used, but wit...

  3. Total Peroxy Nitrates (ΣPNs in the atmosphere: the Thermal Dissociation-Laser Induced Fluorescence (TD-LIF technique and comparisons to speciated PAN measurements

    Directory of Open Access Journals (Sweden)

    B. W. LaFranchi

    2010-05-01

    Full Text Available Peroxyacetyl nitrate (PAN and its chemical analogues are increasingly being quantified in the ambient atmosphere by thermal dissociation (TD followed by detection of either the peroxyacyl radical or the NO2 product. Here we present details of the technique developed at University of California, Berkeley which detects the sum of all peroxynitrates (ΣPNs via laser-induced fluorescence (LIF of the NO2 product. We review the various deployments and compare the Berkeley ΣPNs measurements with the sums of PAN and its homologue species detected individually by other instruments. The observed TD-LIF ΣPNs usually agree to within 10% with the summed individual species, thus arguing against the presence of significant concentrations of unmeasured PAN-type compounds in the atmosphere, as suggested by some photochemical mechanisms. Examples of poorer agreement are attributed to a sampling inlet design that is shown to be inappropriate for high NOx conditions. Interferences to the TD-LIF measurements are described along with strategies to minimize their effects.

  4. Structural, electronic and magnetic properties of Fe, Co, Ni monatomic nanochains encapsulated in armchair LiF nanotubes

    Directory of Open Access Journals (Sweden)

    Nia B. Arghavani

    2017-07-01

    Full Text Available Structural, electronic and magnetic properties of transition metal TM (TM = Fe, Co and Ni atomic chains wrapped in single walled LiF armchair nanotubes have been investigated by the first-principles calculations in the framework of the density functional theory. The generalized gradient approximation (GGA with Hubbard repulsion potential and without Hubbard repulsion was employed to describe the exchange-correlation potential. It is found that all these TM chains @LiFNTs systems have negative formation energy so they are stable and exothermic. Total density of states and partial densities of states analyses show that the spin polarization and the magnetic moment of TM chains @LiFNTs(n,n systems come mostly from the TM atom chains. All these nanocomposites are ferromagnetic (FM and spin splitting between spin up and down is observed. The high magnetic moment and spin polarization of the TM chains @LiFNT(n,n systems show that they can be used as magnetic nanostructures possessing potential current and future applications in permanent magnetism, magnetic recording, and spintronics.

  5. Near-kHz 3D tracer-based LIF imaging of a co-flow jet using toluene

    International Nuclear Information System (INIS)

    Miller, V A; Troutman, V A; Hanson, R K

    2014-01-01

    This work demonstrates tracer-based, high-repetition-rate planar (15 kHz) and three-dimensional (940 Hz) laser-induced fluorescence imaging. An off-the-shelf, pulsed, frequency-quadrupled Nd:YAG laser at 266 nm is used as the excitation light source, and a high-frame-rate intensified relay optic with a slow P46 phosphor coupled to a CMOS camera is used to image the fluorescence. Four different tracers are investigated (3-pentanone, acetone, anisole, and toluene) and relative signal levels are measured in the potential core of a laminar co-flow jet. Resulting SNR values range from 6 to 44 for the different tracers, and relative signal levels and SNR for each tracer are provided as an engineering-basis for tracer-based imaging diagnostic design. It was found that signal levels from anisole (relative to toluene) are about ten times less than suggested by other literature, owing to uncertainty in the reported absorption cross sections. Using toluene as a tracer and a custom-made piezo-actuated steering optic to scan the laser sheet, 3D LIF imaging at 940 Hz is demonstrated by visualizing a co-flow jet mixing with ambient air. (paper)

  6. The neutron response of a 7 LiF thermoluminescent dosimeter incorporated in the UKAEA criticality dosimeter

    International Nuclear Information System (INIS)

    Eid, A.M.; Delafield, H.J.

    1976-04-01

    There are practical advantages in incorporating a 7 LiF thermoluminescent dosimeter (TLD) for the measurement of γ-ray dose, into the personnel criticality dosimeter. This paper investigated the corrections necessary for the inherent direct response of the TLD neutrons, and its enhanced indirect response from prompt γ-rays resulting from neutron interactions with the metallic foils contained in the criticality dosimeter. The response of the TLD to fast fission neutrons was measured to be 0.02 γ rad/n rad. The indirect response of the TLD to thermal neutrons was measured to be 4.8 x 10 -10 rad n -1 cm 2 for dosimeters exposed in free air, and 7 x 10 -10 rad n -1 cm 2 for dosimeters worn on the body respectively. Application of these correction factors to TLD measurements made at International Dosimetry Intercomparisons (sponsored by the I.A.E.A.) gave improved agreement with the values given by other participants. (author)

  7. Production of lithium positive ions from LiF thin films on the anode in PBFA II

    International Nuclear Information System (INIS)

    Green, T.A.; Stinnett, R.W.; Gerber, R.A.

    1995-09-01

    The production of positive lithium ions using a lithium-fluoride-coated stainless steel anode in the particle beam fusion accelerator PBFA II is considered from both the experimental and theoretical points of view. It is concluded that the mechanism of Li + ion production is electric field desorption from the tenth-micron-scale crystallites which compose the columnar growth of the LiF thin film. The required electric field is estimated to be of the order of 5 MV/cm. An essential feature of the mechanism is that the crystallites are rendered electronically conducting through electron-hole pair generation by MeV electron bombardment of the thin film during the operation of the diode. It is proposed that the ion emission mechanism is an electronic conductivity analogue to that discovered by Rollgen for lithium halide crystallites which were rendered ionically conducting by heating to several hundred degrees Celsius. Since an electric field desorption mechanism cannot operate if a surface flashover plasma has formed and reduced the anode electric field to low values, the possibility of flashover on the lithium fluoride coated anode of the PBFA II Li + ion source is studied theoretically. It is concluded with near certainty that flashover does not occur

  8. Estimating the atmospheric concentration of Criegee intermediates and their possible interference in a FAGE-LIF instrument

    Science.gov (United States)

    Novelli, Anna; Hens, Korbinian; Tatum Ernest, Cheryl; Martinez, Monica; Nölscher, Anke C.; Sinha, Vinayak; Paasonen, Pauli; Petäjä, Tuukka; Sipilä, Mikko; Elste, Thomas; Plass-Dülmer, Christian; Phillips, Gavin J.; Kubistin, Dagmar; Williams, Jonathan; Vereecken, Luc; Lelieveld, Jos; Harder, Hartwig

    2017-06-01

    We analysed the extensive dataset from the HUMPPA-COPEC 2010 and the HOPE 2012 field campaigns in the boreal forest and rural environments of Finland and Germany, respectively, and estimated the abundance of stabilised Criegee intermediates (SCIs) in the lower troposphere. Based on laboratory tests, we propose that the background OH signal observed in our IPI-LIF-FAGE instrument during the aforementioned campaigns is caused at least partially by SCIs. This hypothesis is based on observed correlations with temperature and with concentrations of unsaturated volatile organic compounds and ozone. Just like SCIs, the background OH concentration can be removed through the addition of sulfur dioxide. SCIs also add to the previously underestimated production rate of sulfuric acid. An average estimate of the SCI concentration of ˜ 5.0 × 104 molecules cm-3 (with an order of magnitude uncertainty) is calculated for the two environments. This implies a very low ambient concentration of SCIs, though, over the boreal forest, significant for the conversion of SO2 into H2SO4. The large uncertainties in these calculations, owing to the many unknowns in the chemistry of Criegee intermediates, emphasise the need to better understand these processes and their potential effect on the self-cleaning capacity of the atmosphere.

  9. Operation of passive wax flashover and LiF ion sources on extraction applied-B ion diodes on SABRE

    International Nuclear Information System (INIS)

    Cuneo, M.E.; Hanson, D.L.; Smith, J.R.; Rosenthal, S.E.; Coats, R.S.; Bernard, M.A.

    1993-01-01

    The authors are fielding wax flashover and LiF anodes on an extraction ion diode on SABRE (Sandia Accelerator and Beam Research Experiment), a magnetically insulated linear induction voltage adder, presently providing a 6 MV, 300 kA output. These anodes are passive sources of principally hydrocarbon and lithium beams. In applied-B ion diodes, passive ion sources use the applied voltage to produce the required ions either through an electron assisted desorption and surface flashover process, and/or through field emission mechanisms. Passive sources therefore require power delivered to the diode before ions will be turned-on. Passive sources provide a simple way to generate ions to test accelerator performance, accelerator to diode coupling, diagnostics, and to study sources of divergence and divergence reduction techniques. The authors will discuss the effect of magnetic field geometry and the important role of cathode feed electrons in the formation and evolution of the A-K gap electron sheath in the diode. Experimental data on diode operation and beam production will be compared to the predictions of PIC code simulations

  10. Numerical evaluation of droplet sizing based on the ratio of fluorescent and scattered light intensities (LIF/Mie technique)

    International Nuclear Information System (INIS)

    Charalampous, Georgios; Hardalupas, Yannis

    2011-01-01

    The dependence of fluorescent and scattered light intensities from spherical droplets on droplet diameter was evaluated using Mie theory. The emphasis is on the evaluation of droplet sizing, based on the ratio of laser-induced fluorescence and scattered light intensities (LIF/Mie technique). A parametric study is presented, which includes the effects of scattering angle, the real part of the refractive index and the dye concentration in the liquid (determining the imaginary part of the refractive index). The assumption that the fluorescent and scattered light intensities are proportional to the volume and surface area of the droplets for accurate sizing measurements is not generally valid. More accurate sizing measurements can be performed with minimal dye concentration in the liquid and by collecting light at a scattering angle of 60 deg. rather than the commonly used angle of 90 deg. Unfavorable to the sizing accuracy are oscillations of the scattered light intensity with droplet diameter that are profound at the sidescatter direction (90 deg.) and for droplets with refractive indices around 1.4.

  11. X-ray diffraction measurements to determine longitudinal and transverse lattice deformation in shocked LiF

    International Nuclear Information System (INIS)

    Rigg, P.A.; Gupta, Y.M.

    2000-01-01

    Experimental methods using both single and multiple x-ray diffraction were developed to determine real time, lattice deformation in directions parallel and perpendicular to shock wave propagation in single crystals subjected to plate impact loading. Initial experiments used single diffraction to monitor the interplanar spacing change, parallel to the shock propagation direction, in LiF crystals shocked along the [111] and [100] directions. These measurements, in combination with the macroscopic volume compression, were used to determine the state of compression of the unit cell. Subsequent development of a multiple diffraction technique permitted simultaneous determination of both the longitudinal and transverse lattice deformations. The present results showed that shock compression, below 4 GPa, along the [111] orientation--which results in macroscopic elastic deformation - produced one-dimensional unit cell compression. In contrast, shock compression along the [100] orientation - which results in macroscopic elastic-plastic deformation--produced isotropic unit cell compression. The implications of the present results and the ability to make quantitative x-ray diffraction measurements under shock loading are discussed

  12. Differential expression of growth factors in irradiated mouse testes

    International Nuclear Information System (INIS)

    Mauduit, Claire; Siah, Ahmed; Foch, Marie; Chapet, Olivier; Clippe, Sebastien; Gerard, Jean-Pierre; Benahmed, Mohamed

    2001-01-01

    Purpose: By using as an experimental model the male mouse gonad, which contains both radiosensitive (germ) and radioresistant (somatic) cells, we have studied the growth factor (and/or receptor) expression of transforming growth factor-β receptor (TGFβ RI), stem cell factor (SCF), c-kit, Fas-L, Fas, tumor necrosis factor receptor (TNF R55), and leukemia inhibiting factor receptor (LIF-R) after local irradiation. Methods and Materials: Adult male mice were locally irradiated on the testes. Induction of apoptosis in the different testicular cell types following X-ray radiation was identified by the TdT-mediated dUTP Nick End Labeling (TUNEL) approach. Growth factor expression was evidenced by semiquantitative RT-PCR and Western blot analyses. Results: Apoptosis, identified through the TUNEL approach, occurred in radiosensitive testicular (premeotic) germ cells with the following kinetics: the number of apoptotic cells increased after 24 h (p<0.001) and was maximal 48 h after a 2-Gy ionizing radiation (p<0.001). Apoptotic cells were no longer observed 72 h after a 2-Gy irradiation. The number of apoptotic cells increased with the dose of irradiation (1-4 Gy). In the seminiferous tubules, the growth factor expression in premeiotic radiosensitive germ cells was modulated by irradiation. Indeed Fas, c-kit, and LIF-R expression, which occurs in (radiosensitive) germ cells, decreased 24 h after a 2-Gy irradiation, and the maximal decrease was observed with a 4-Gy irradiation. The decrease in Stra8 expression occurred earlier, at 4 h after a 2-Gy irradiation. In addition, a significant (p<0.03) decrease in Stra8 mRNA levels was observed at the lowest dose used (0.5 Gy, 48 h). Moreover, concerning a growth factor receptor, such as TGFβ RI, which is expressed both in radiosensitive and radioresistant cells, we observed a differential expression depending on the cell radiosensitivity after irradiation. Indeed, TGFβ RI expression was increased after irradiation in

  13. Elastic wave from fast heavy ion irradiation on solids

    CERN Document Server

    Kambara, T; Kanai, Y; Kojima, T M; Nanai, Y; Yoneda, A; Yamazaki, Y

    2002-01-01

    To study the time-dependent mechanical effects of fast heavy ion irradiations, we have irradiated various solids by a short-bunch beam of 95 MeV/u Ar ions and observed elastic waves generated in the bulk. The irradiated targets were square-shaped plates of poly-crystals of metals (Al and Cu), invar alloy, ceramic (Al sub 2 O sub 3), fused silica (SiO sub 2) and single crystals of KC1 and LiF with a thickness of 10 mm. The beam was incident perpendicular to the surface and all ions were stopped in the target. Two piezo-electric ultrasonic sensors were attached to the surface of the target and detected the elastic waves. The elastic waveforms as well as the time structure and intensity of the beam bunch were recorded for each shot of a beam bunch. The sensor placed opposite to the beam spot recorded a clear waveform of the longitudinal wave across the material, except for the invar and fused silica targets. From its propagation time along with the sound velocity and the thickness of the target, the depth of the...

  14. The gonad dose produced by a 60Co irradiation of peripheral, interpleural, and retroperitoneal lymph node groups

    International Nuclear Information System (INIS)

    Hassenstein, E.; Nuesslin, F.; Medizinische Hochschule Hannover

    1976-01-01

    A telecobalt therapy of lymph node groups was simulated on the Alderson phantom and the gonad dose caused by each irradiation field was measured with LiF dosimeters. When the supradiaphragmatic and the para-aortal lymph nodes were irradiated, the ovary dose showed rates up to 20 per thousand of the dose maximum. The irradiation of the same zones brought about a testicle dose of less than 5 per thousand of the dose maximum, and only 1/20 of this rate was achieved when a lead plate of about four cm was used in order to protect the testicles. The results are discussed under the point of view of the genetic risk. (orig.) [de

  15. Biology of food irradiation

    International Nuclear Information System (INIS)

    Murray, D.R.

    1990-01-01

    The author presents his arguments for food scientists and biologists that the hazards of food irradiation outweigh the benefits. The subject is discussed in the following sections: introduction (units, mutagenesis, seed viability), history of food irradiation, effects of irradiation on organoleptic qualities of staple foods, radiolytic products and selective destruction of nutrients, production of microbial toxins in stored irradiated foods and loss of quality in wheat, deleterious consequences of eating irradiated foods, misrepresentation of the facts about food irradiation. (author)

  16. The effect of Li2O and LiF on structural properties of cobalt doped borate glasses

    Directory of Open Access Journals (Sweden)

    A.M. Abdelghany

    2017-10-01

    Full Text Available Two glassy (LiF–B2O3 and (Li2O–B2O3 systems containing different content of CoO dopants (0.05, 0.1, 0.15, 0.2 wt% were prepared. UV/Vis optical absorption of base glasses reveals a strong UV absorption bands attributed to unavoidable contaminated trace iron impurities. CoO-doped glasses show extra three visible bands due to both octahedral and tetrahedral Co2+ ions related to the little variation between energies of ligand field stabilization between the two coordination states. Fluoride containing glasses show limited variations in the spectral properties due to the different ligand strength of the anions (F− and O2−. FTIR spectra display characteristic modes of vibrations due to triangular and tetrahedral borate groups. It is assumed that LiF acts as Li2O in promoting the formation of tetrahedral (BO3F units which possess the same wavenumber position for vibrations of (BO4 units in the range of 800–1200 cm−1. CoO causes no distinct variations in number or position of characteristic IR vibrational bands due to their low dopant level (0.05–0.2%. A new suggested trial has been utilized to calculate the percent of four coordinated borons from both optical and FTIR spectra to give more insight on the role of CoO as dopant on these spectral properties and on the calculated parameters.

  17. Irradiation Facilities at CERN

    CERN Document Server

    Gkotse, Blerina; Carbonez, Pierre; Danzeca, Salvatore; Fabich, Adrian; Garcia, Alia, Ruben; Glaser, Maurice; Gorine, Georgi; Jaekel, Martin, Richard; Mateu,Suau, Isidre; Pezzullo, Giuseppe; Pozzi, Fabio; Ravotti, Federico; Silari, Marco; Tali, Maris

    2017-01-01

    CERN provides unique irradiation facilities for applications in many scientific fields. This paper summarizes the facilities currently operating for proton, gamma, mixed-field and electron irradiations, including their main usage, characteristics and information about their operation. The new CERN irradiation facilities database is also presented. This includes not only CERN facilities but also irradiation facilities available worldwide.

  18. Quantification of apoptotic DNA fragmentation in a transformed uterine epithelial cell line, HRE-H9, using capillary electrophoresis with laser-induced fluorescence detector (CE-LIF).

    Science.gov (United States)

    Fiscus, R R; Leung, C P; Yuen, J P; Chan, H C

    2001-01-01

    Apoptotic cell death of uterine epithelial cells is thought to play an important role in the onset of menstruation and the successful implantation of an embryo during early pregnancy. Abnormal apoptosis in these cells can result in dysmenorrhoea and infertility. In addition, decreased rate of epithelial apoptosis likely contributes to endometriosis. A key step in the onset of apoptosis in these cells is cleavage of the genomic DNA between nucleosomes, resulting in polynucleosomal-sized fragments of DNA. The conventional technique for assessing apoptotic DNA fragmentation uses agarose (slab) gel electrophoresis (i.e. DNA laddering). However, recent technological advances in the use of capillary electrophoresis (CE), particularly the introduction of the laser-induced fluorescence detector (LIF), has made it possible to perform DNA laddering with improved automation and much greater sensitivity. In the present study, we have further developed the CE-LIF technique by using a DNA standard curve to quantify accurately the amount of DNA in the apoptotic DNA fragments and have applied this new quantitative technique to study apoptosis in a transformed uterine epithelial cell line, the HRE-H9 cells. Apoptosis was induced in the HRE-H9 cells by serum deprivation for 5, 7 and 24 h, resulting in increased DNA fragmentation of 2.2-, 3.1- and 6.2-fold, respectively, above the 0 h or plus-serum controls. This ultrasensitive CE-LIF technique provides a novel method for accurately measuring the actions of pro- or anti-apoptotic agents or conditions on uterine epithelial cell lines. Copyright 2001 Academic Press.

  19. Perspective on food irradiation

    International Nuclear Information System (INIS)

    Newsome, R.L.

    1987-01-01

    A brief review summarizes current scientific information on the safety and efficacy of irradiation processing of foods. Attention is focused on: specifics of the irradiation process and its effectiveness in food preservation; the historical development of food irradiation technology in the US; the response of the Institute of Food Technologists to proposed FDA guidelines for food irradiation; the potential uses of irradiation in the US food industry; and the findings of the absence of toxins and of unaltered nutrient density (except possibly for fats) in irradiated foods. The misconceptions of consumers concerning perceived hazards associated with food irradiation, as related to consumer acceptance, also are addressed

  20. Comparison between the distribution of the calculated dose and the media with thermoluminescent dosemeters 7 LiF in bladder tumor

    International Nuclear Information System (INIS)

    Araujo, A.M.C. de.

    1974-01-01

    For the central plane of an assumed malignant tumor of the bladder, Cobalt - 60 treatment plans were calculated from published isodose curves. The calculation was done for the three field technique, unbalanced and balanced, and for 120 degree rotational therapy with wedge filter. A Rando-Alderson phantom and calibrated encapsulated 7 LiF dosimeters with a standard deviation better than 3% of each were used to verify the treatment plans. Furthermore the dose distribution to an assumed extension of the tumor and to the rectum were measured. (author)

  1. Oxygen imaging at the sediment-water interface using lifetime-based laser induced fluorescence (tau LIF) of nano-sized particles

    DEFF Research Database (Denmark)

    Murniati, E.; Gross, D.; Herlina, H.

    2016-01-01

    Most applications of laser induced fluorescence (LIF) for dissolved oxygen (DO) imaging in flowing water are based on luminescence intensity measurements of a dissolved indicator. A major limitation for applying the technique in the bottom boundary layer (BBL) is the sorption of the luminescent dye...... to organic surfaces at the sediment. Many sediment and soil studies have used planar optodes on transparent foils as an imaging technique for observing concentration distributions across the sediment-water interface. The presence of the foil, however, is restricting the free flow and therewith the DO...

  2. Scattering of H(D) from LiF(1 0 0) under fast grazing incidence conditions: To what extent is classical dynamics a useful tool?

    Energy Technology Data Exchange (ETDEWEB)

    Muzas, A.S. [Departamento de Química Módulo 13, Universidad Autónoma de Madrid, 28049 Madrid (Spain); Martín, F. [Departamento de Química Módulo 13, Universidad Autónoma de Madrid, 28049 Madrid (Spain); Instituto Madrileño de Estudios Avanzados en Nanociencia (IMDEA-nanociencia), Cantoblanco, 28049 Madrid (Spain); Díaz, C., E-mail: cristina.diaz@uam.es [Departamento de Química Módulo 13, Universidad Autónoma de Madrid, 28049 Madrid (Spain)

    2015-07-01

    Diffraction experiments of atoms and molecules under fast grazing incidence conditions have opened a new field in surface science. This experimental effort calls for complementary theoretical studies, which would allow a detailed analysis of experimental data. Here, we have analyzed the ability of classical dynamics simulations to reproduce experimental results. To perform this study, a DFT (density functional theory) based potential energy surface, describing the interaction between a H atom and a LiF(1 0 0) surface, has been computed. Diffraction probabilities have been simulated by means of a classical binning method. Our results have been found to be in qualitative good agreement with recent experimental measurements.

  3. Development and implementation of an anthropomorphic pediatric spine phantom for the assessment of craniospinal irradiation procedures in proton therapy

    Directory of Open Access Journals (Sweden)

    Dana J Lewis

    2014-03-01

    Full Text Available Purpose: To design an anthropomorphic pediatric spine phantom for use in the evaluation of proton therapy facilities for clinical trial participation by the Imaging and Radiation Oncology Core (IROC Houston QA Center (formerly RPC.Methods: This phantom was designed to perform an end-to-end audit of the proton spine treatment process, including simulation, dose calculation by the treatment planning system (TPS, and proton treatment delivery. The design incorporated materials simulating the thoracic spinal column of a pediatric patient, along with two thermoluminescent dosimeter (TLD-100 capsules and radiochromic film embedded in the phantom for dose evaluation. Fourteen potential materials were tested to determine relative proton stopping power (RSP and Hounsfield unit (HU values. Each material was CT scanned at 120 kVp, and the RSP was obtained from depth ionization scans using the Zebra multi-layer ion chamber (MLIC at two energies: 160 MeV and 250 MeV. To determine tissue equivalency, the measured RSP for each material was compared to the RSP calculated by the Eclipse TPS for a given HU.Results: The materials selected as bone, tissue, and cartilage substitutes were Techron HPV Bearing Grade (Boedeker Plastics, Inc., solid water, and blue water, respectively. The RSP values did not differ by more than 1.8% between the two energies. The measured RSP for each selected material agreed with the RSP calculated by the Eclipse TPS within 1.2%.Conclusion: An anthropomorphic pediatric proton spine phantom was designed to evaluate proton therapy delivery. The inclusion of multiple tissue substitutes increases heterogeneity and the level of difficulty for institutions to successfully treat the phantom. The following attributes will be evaluated: absolute dose agreement, distal range, field width, junction match and right/left dose profile alignment. The phantom will be tested at several institutions using a 5% dose agreement criterion, and a 5%/3mm gamma

  4. A new LIF instrument for aircraft related and ground related masurements of OH and HO{sub 2} radicals in the troposphere; Ein neues LIF-Instrument fuer flugzeug- und bodengebundene Messungen von OH- und HO{sub 2}-Radikalen in der Troposphaere

    Energy Technology Data Exchange (ETDEWEB)

    Broch, Sebastian

    2011-07-01

    The author of the contribution under consideration describes the development and characterization of an instrument for the measurement of OH and HO{sub 2} radicals by means of laser-induced fluorescence (LIF). This instrument can be used from the lower troposphere to the lower stratosphere both on the ground and in aircraft applications. After describing the basics of the OH radical chemistry and the measurement principle of laser-induced fluorescence, a new instrument is presented. The LIF measuring cells needs long inlet pipes which lead to a modification of the verification of OH radicals. The effect of these modifications as well as the height dependence of the detection sensitivity for the OH radicals is examined. A model for the theoretical description of the altitude dependence of the detection sensitivity is described. The modification of the measuring cell influences the ozone-water interference in the LIF measurement system. Therefore, the author develops a model to describe the interference in the new system and evaluate this model by measurements. The applicability of this new instrument for ground and flight applications is analyzed in the range from 0 to 18 kilometers regarding sensitivity, detection limit and interference.

  5. Evaluation of the accuracy of thermal dissociation CRDS and LIF techniques for atmospheric measurement of reactive nitrogen species

    Science.gov (United States)

    Womack, Caroline C.; Neuman, J. Andrew; Veres, Patrick R.; Eilerman, Scott J.; Brock, Charles A.; Decker, Zachary C. J.; Zarzana, Kyle J.; Dube, William P.; Wild, Robert J.; Wooldridge, Paul J.; Cohen, Ronald C.; Brown, Steven S.

    2017-05-01

    The sum of all reactive nitrogen species (NOy) includes NOx (NO2 + NO) and all of its oxidized forms, and the accurate detection of NOy is critical to understanding atmospheric nitrogen chemistry. Thermal dissociation (TD) inlets, which convert NOy to NO2 followed by NO2 detection, are frequently used in conjunction with techniques such as laser-induced fluorescence (LIF) and cavity ring-down spectroscopy (CRDS) to measure total NOy when set at > 600 °C or speciated NOy when set at intermediate temperatures. We report the conversion efficiency of known amounts of several representative NOy species to NO2 in our TD-CRDS instrument, under a variety of experimental conditions. We find that the conversion efficiency of HNO3 is highly sensitive to the flow rate and the residence time through the TD inlet as well as the presence of other species that may be present during ambient sampling, such as ozone (O3). Conversion of HNO3 at 400 °C, nominally the set point used to selectively convert organic nitrates, can range from 2 to 6 % and may represent an interference in measurement of organic nitrates under some conditions. The conversion efficiency is strongly dependent on the operating characteristics of individual quartz ovens and should be well calibrated prior to use in field sampling. We demonstrate quantitative conversion of both gas-phase N2O5 and particulate ammonium nitrate in the TD inlet at 650 °C, which is the temperature normally used for conversion of HNO3. N2O5 has two thermal dissociation steps, one at low temperature representing dissociation to NO2 and NO3 and one at high temperature representing dissociation of NO3, which produces exclusively NO2 and not NO. We also find a significant interference from partial conversion (5-10 %) of NH3 to NO at 650 °C in the presence of representative (50 ppbv) levels of O3 in dry zero air. Although this interference appears to be suppressed when sampling ambient air, we nevertheless recommend regular

  6. Simple preparation of LiF:Mg,Ti phosphor

    International Nuclear Information System (INIS)

    Moharil, S.V.; Shahare, D.I.; Upaded, S.V.; Deshmukh, B.T.

    1993-01-01

    LiF-TLD 100 is a low-impedance (Z eff = 8.2) tissue equivalent material which is widely used in thermoluminescence (TL) dosimetry of ionizing radiations and personnel monitoring. Mg and Ti have been found to be the major impurities which impart the Tl characteristics. Recipes for the preparation of this phosphor, have not been found to be satisfactory for routine manufacture; there have always been problems associated with reproducibility and even with batch homogeneity. One of the reasons for this is that most procedures start either from readily available LiF or by melting the synthesized LiF, or both. The background impurities in the starting LiF powder can mask the intentional impurities, particularly Ti which has to be doped in rather small concentrations (10 p.p.m.). Melting LiF can again be tricky, as the LiF melt is volatile and highly corrosive. In this letter we report the preparation of LiF: Mg, Ti. The impurities were incorporated during the synthesis of LiF. The phosphor was prepared by heat treatments in ambient air without melting the compound. The characteristics of the prepared phosphors were studied and compared with those of LiF-TLD 100. (author)

  7. Comparison and development of advanced dosimetric techniques to be used under extreme climatic conditions

    International Nuclear Information System (INIS)

    Madhvanath, U.

    1975-08-01

    The post-irradiation fading characteristics of various dosimeters in function of relative humidity of air during storage were tested in specially set up humidity boxes. The temperature and relative humidity were varied between 5deg-35degC and 40-90%, respectively. Fading was 70% and 80% at 2 and 6 days respectively, for Kodak Type 2 film under 28degC and 76% relative humidity. Under these conditions the corresponding values for NTA emulsions were 30% and 80% respectively. Agfa-Gevaert films proved to be less sensitive and gave 20% and 30%, respectively, for the mentioned intervals. When Kodak Type 2 film was sealed in polythene bags, fading was reduced considerably, to appr. 15% in 4 weeks. Alternate storage of exposed films in humid and dry conditions also reduced fading to the same extent. When NTA emulsions were double-sealed with desiccant inside fading was reduced to 10% in 15 days. CaSO 4 :Dy (DRP and Harshaw) showed only 7% fading in 3 months. LiF TLD-100 was more sensitive, 13% in 2 months. Gamma-irradiated Li-borate has faded up to 30% at extreme climatic conditions in 3 months but thermal neutron irradiated Li-borate was resistant against fading for this period

  8. Comparison and development of advanced dosimetric techniques to be used under extreme climatic conditions. Final report for the period 1 November 1971--28 December 1974

    Energy Technology Data Exchange (ETDEWEB)

    Madhvanath, U

    1975-08-01

    The post-irradiation fading characteristics of various dosimeters in function of relative humidity of air during storage were tested in specially set up humidity boxes. The temperature and relative humidity were varied between 5 and 35degC and 40-90%, respectively. Fading was 70% and 80% at 2 and 6 days respectively, for Kodak Type 2 film under 28degC and 76% relative humidity. Under these conditions the corresponding values for NTA emulsions were 30% and 80% respectively. Agfa-Gevaert films proved to be less sensitive and gave 20% and 30%, respectively, for the mentioned intervals. When Kodak Type 2 film was sealed in polythene bags, fading was reduced considerably, to appr. 15% in 4 weeks. Alternate storage of exposed films in humid and dry conditions also reduced fading to the same extent. When NTA emulsions were double-sealed with desiccant inside fading was reduced to 10% in 15 days. CaSO/sub 4/:Dy (DRP and Harshaw) showed only 7% fading in 3 months. LiF TLD-100 was more sensitive, 13% in 2 months. Gamma-irradiated Li-borate has faded up to 30% at extreme climatic conditions in 3 months but thermal neutron irradiated Li-borate was resistant against fading for this period.

  9. Creativity in Lif

    Directory of Open Access Journals (Sweden)

    José Alberto Rubí-Barquero

    2011-11-01

    Full Text Available In this paper, the author explains the following ideas: that creativity is not restricted to the sphere of art, as it is usually considered, since art is just an expression of creativity; that people do many things that require creativity; and that not even creativity is an attribute of humans, since, from certain critical levels, we may observe behaviors in living beings that involve different degrees of aesthetic cognition.

  10. Electron beam irradiating device

    Energy Technology Data Exchange (ETDEWEB)

    Shinohara, K

    1969-12-20

    The efficiency of an electron beam irradiating device is heightened by improving the irradiation atmosphere and the method of cooling the irradiation window. An irradiation chamber one side of which incorporates the irradiation windows provided at the lower end of the scanner is surrounded by a suitable cooling system such as a coolant piping network so as to cool the interior of the chamber which is provided with circulating means at each corner to circulate and thus cool an inert gas charged therewithin. The inert gas, chosen from a group of such gases which will not deleteriously react with the irradiating equipment, forms a flowing stream across the irradiation window to effect its cooling and does not contaminate the vacuum exhaust system or oxidize the filament when penetrating the equipment through any holes which the foil at the irradiation window may incur during the irradiating procedure.

  11. Spatially resolved analyses of uranium species using a coupled system made up of confocal laser-scanning microscopy (CLSM) and laser induced fluorescence spectroscopy (LIFS)

    International Nuclear Information System (INIS)

    Brockmann, S.; Grossmann, K.; Arnold, T.

    2014-01-01

    The fluorescent properties of uranium when excited by UV light are used increasingly for spectroscope analyses of uranium species within watery samples. Here, alongside the fluorescent properties of the hexavalent oxidation phases, the tetra and pentavalent oxidation phases also play an increasingly important role. The detection of fluorescent emission spectrums on solid and biological samples using (time-resolved) laser induced fluorescence spectroscopy (TRLFS or LIFS respectively) has, however, the disadvantage that no statements regarding the spatial localisation of the uranium can be made. However, particularly in complex, biological samples, such statements on the localisation of the uranium enrichment in the sample are desired, in order to e.g. be able to distinguish between intra and extra-cellular uranium bonds. The fluorescent properties of uranium (VI) compounds and minerals can also be used to detect their localisation within complex samples. So the application of fluorescent microscopic methods represents one possibility to localise and visualise uranium precipitates and enrichments in biological samples, such as biofilms or cells. The confocal laser-scanning microscopy (CLSM) is especially well suited to this purpose. Coupling confocal laser-scanning microscopy (CLSM) with laser induced fluorescence spectroscopy (LIFS) makes it possible to localise and visualise fluorescent signals spatially and three-dimensionally, while at the same time being able to detect spatially resolved, fluorescent-spectroscopic data. This technology is characterised by relatively low detection limits from up to 1.10 -6 M for uranium (VI) compounds within the confocal volume. (orig.)

  12. An ultracold neutron (UCN) detector with Ti/ sup 6 LiF multi-layer converter and sup 5 sup 8 Ni reflector

    CERN Document Server

    Maier-Komor, P; Bergmaier, A; Dollinger, G; Paul, S; Petzoldt, G; Schott, W

    2002-01-01

    High efficient detectors for ultracold neutrons (UCN) must be developed for the new high flux neutron source Forschungsreaktor Muenchen II (FRM II). On silicon PIN diodes 76 mu g/cm sup 2 sup 5 sup 8 Ni was deposited as a UCN reflector. On this 100 double layers of sup n sup a sup t Ti (4.7 mu g/cm sup 2) and sup 6 LiF (1.8 mu g/cm sup 2) were deposited to function as a UCN converter. On top of this, 33 double layers of sup n sup a sup t Ti (3.4 mu g/cm sup 2) and sup 6 LiF (0.92 mu g/cm sup 2) were condensed in addition to provide sensitivity to very low-energy UCN. Finally, 6.0 mu g/cm sup 2 sup n sup a sup t V was deposited to protect the multi-layers. Vanadium has nearly zero optical potential for UCN and thus should not hinder their transmission. Since no expensive isotopes were involved, a source to substrate distance of 24 cm could be chosen, leading to excellent uniformity. The setup designed for deposition under ultrahigh vacuum conditions and the evaporation procedures are described.

  13. LIF excitation spectra for S 0 → S 1 transition of deuterated anthranilic acid COOD, ND 2 in supersonic-jet expansion

    Science.gov (United States)

    Kolek, Przemysław; Leśniewski, Sebastian; Andrzejak, Marcin; Góra, Maciej; Cias, Pawel; Weģrzynowicz, Adam; Najbar, Jan

    2010-12-01

    Laser induced fluorescence (LIF) excitation spectrum for the S 0 → S 1 transition of anthranilic acid molecules deuterated in the substituent groups (COOD, ND 2) was investigated. Analysis of the LIF spectrum allowed for the assignment of the six most prominent fundamental in-plane modes of frequencies up to ca. 850 cm. The experimental results show good correlation with the frequency changes upon deuteration computed with CIS (CI-Singles) and TD-DFT for the S 1 state. Deuteration induced red-shifts of the identified fundamental bands are used for examination of the alternative assignments proposed in earlier studies. Potential energy distributions (PED) and overlaps of the in-plane normal modes with frequencies below 850 cm indicate that the correspondence of the respective vibrations of the deuterated and non-deuterated molecule is very good. A blue-shift of the 00 transition due to the isotopic substitution, is equal to 47 cm. This relatively large value is caused primarily by a significant decrease of the N-H stretching frequency associated with the increase of strength of the intramolecular hydrogen bond upon the electronic excitation. The deuteration shift of the 00 band was interpreted in terms of the differences of the zero point energy (ZPE) between the S 0 and S 1 electronic states, computed with DFT and TD-DFT methods, respectively.

  14. Laser Induced Fluorescence (LIF) Measurements of Neutral (ArI) and singly-ionized (ArII) Argon in a LargeScale Helicon Plasma

    Science.gov (United States)

    Kelly, R. F.; Fisher, D. M.; Hatch, M. W.; Gilmore, M.; Dwyer, R. H.; Meany, K.; Zhang, Y.; Desjardins, T. R.

    2017-10-01

    In order to investigate the role of neutral dynamics in helicon discharges in the HelCat (Helicon-Cathode) plasma device at U. New Mexico, a Laser Induced Fluorescence (LIF) system has been developed. The LIF system is based on a >250 mW, tunable diode laser with a tuning range between 680 and 700nm. For neutral Argon, the laser pumps the metastable (2P3/20) 4s level to the (2P1/20) 4p level using 696. 7352 nm light. The fluorescence radiation from decay to the (2P1/20) 4s level at 772. 6333 nm is observed. For singly ionized Argon, the laser pumps the 3s23p4(3 P)3d level to the 3s23p4(3 P)4p level using 686.3162nm light. The fluorescence radiation from the decay to the 3s23p4(3 P)4s level is observed. The system design, and velocity measurements in the axial, azimuthal and radial directions for ArI, and in the axial direction for ArII will be presented. Supported by U.S. National Science Foundation Award 1500423.

  15. Irradiation of goods

    International Nuclear Information System (INIS)

    Huebner, G.

    1992-01-01

    The necessary dose and the dosage limits to be observed depend on the kind of product and the purpose of irradiation. Product density and density distribution, product dimensions, but also packaging, transport and storage conditions are specific parameters influencing the conditions of irradiation. The kind of irradiation plant - electron accelerator or gamma plant - , its capacity, transport system and geometric arrangement of the radiation field are factors influencing the irradiation conditions as well. This is exemplified by the irradiation of 3 different products, onions, deep-frozen chicken and high-protein feed. Feasibilities and limits of the irradiation technology are demonstrated. (orig.) [de

  16. Experimental study on the ionizing radiation field in absorbers irradiated by the 0.8 GeV and 1.2 GeV electrons

    International Nuclear Information System (INIS)

    Ambrosimov, V.K.; Kalmykov, N.N.; Kovalenko, G.D.

    1987-01-01

    The measurement results of spatial distribution of aluminium detector energy release and radioactivity in absorbers irradiated by 0.8 and 1.2 GeV electrons are given. Absorbers are made of aluminium, iron and lead, 30x30 cm size across the thickness is about 18 radiation length units. Thermoluminescence dosimeters LiF and radiochromium film dosimeters have been used to measure energy release. Induced activity of 18 F and 24 Na nuclides is determined in aluminium detectors. The experimental data are compared with the results of calculation carried out by the Monte-Carlo method

  17. Fabrication and characterization of new LiF: Eu{sup 3+} sintered phosphors exposed to beta particles

    Energy Technology Data Exchange (ETDEWEB)

    Garcia H, A.R.; Cruz V, C. [Depto. de Investigacion en Polimeros y Materiales de la Universidad de Sonora, A.P. 130, 83000 Hermosillo, Sonora (Mexico); Bernal, R.; Barboza F, M. [Universidad de Sonora, A.P. 5-088, 83190 Hermosillo, Sonora (Mexico); Kitis, G. [Nuclear Physics Laboratory, Aristotle University of Thessaloniki, 54124 (Greece); Castano, V.M. [IFUNAM, A.P. 1-1010, 76000 Queretaro (Mexico)

    2006-07-01

    Pellet-shaped LiF:Eu{sup 3+} phosphors were synthesized by sintering. To improve their thermoluminescence characteristics, different growth conditions were used. Thermal annealing at 750 C during 5 h under air atmosphere provided the samples with highest sensitivity. Characteristic glow curves exhibit an absolute maximum centered at 203 C, and another less intense peak between 250 and 300 C. The first peak has a position very suitable for dosimetry applications. Beta irradiated samples displayed a thermoluminescence response that increases as the radiation dose increased in the 0.16 - 42.0 Gy range. A fast fading of less than 20 % occurs in the first 10 s after irradiation, followed by a remarkable stability at room temperature. Computerized glow curve deconvolution of experimental data obtained applying the McKeever method to resolve the individual peaks revealed that the glow curves fits to nine individual peaks. Activation energies were computed by using the initial rise method. (Author)

  18. Thermoluminescent response of LiF: Mg, Cu, P (GR-200) below an electron beam of 6 MeV

    International Nuclear Information System (INIS)

    Torijano C, E.F.S.; Azorin N, J.; Villasenor N, I.; Lujan C, P.J.; Rivera M, T.

    2007-01-01

    Full text: In this work the experimental results of studying the thermoluminescent response (TL) of LiF:Mg,Cu,P (GR-200) previously irradiated with 6 MeV electrons are presented. The electrons beam was generated by a Lineal Accelerator VARIAN I for medical use. The lineal accelerator is installed in the General Hospital of Mexico (HGM). A lot of 25 thermoluminescent dosemeters (DTL) was used. The mass and volume of each one of them were determined. Obtaining a variation of 14% in standard deviation (SD). The DTLs were irradiated to an energy of 6 MeV. The dose given to the DTL was of 50 c Gy. The linearity of the response of the GR-200 also was determined. (Author)

  19. Facts about food irradiation: Food irradiation costs

    International Nuclear Information System (INIS)

    1991-01-01

    This fact sheet gives the cost of a typical food irradiation facility (US $1 million to US $3 million) and of the food irradiation process (US $10-15 per tonne for low-dose applications; US $100-250 per tonne for high-dose applications). These treatments also bring consumer benefits in terms of availability, storage life and improved hygiene. 2 refs

  20. Food irradiation in China

    International Nuclear Information System (INIS)

    Zhu Jiang

    1994-01-01

    In this paper, the author discussed the recent situation of food irradiation in China, its history, facilities, clearance, commercialization, and with emphasis on market testing and public acceptance of irradiated food. (author)

  1. Dosimetry for Crystals Irradiation

    CERN Document Server

    Lecomte, Pierre

    2005-01-01

    Before shipment to CMS, all PbWO4 crystals produced in China are irradiated there with 60 Co , in order to insure that the induced absorption coefficient is within specifications. Acceptance tests at CERNand at ENEA also include irradiation with gamma rays from 60 Co sources. There were initially discrepancies in quoted doses and doserates as well as in induced absorption coefficients. The present work resolves the discrepancies in irradiation measurements and defines common dosimetry methods for consistency checks between irradiation facilities.

  2. Irradiation and flavor

    International Nuclear Information System (INIS)

    Reineccius, G.A.

    1992-01-01

    Flavor will not be a significant factor in determining the success of irradiated foods entering the U.S. market. The initial applications will use low levels of irradiation that may well result in products with flavor superior to that of products from alternative processing techniques (thermal treatment or chemical fumigation). The success of shelf-stable foods produced via irradiation may be much more dependent upon our ability to deal with the flavor aspects of high levels of irradiation

  3. Food irradiation makes progress

    International Nuclear Information System (INIS)

    Kooij, J. van

    1984-01-01

    In the past fifteen years, food irradiation processing policies and programmes have been developed both by a number of individual countries, and through projects supported by FAO, IAEA and WHO. These aim at achieving general acceptance and practical implementation of food irradiation through rigorous investigations of its wholesomeness, technological and economic feasibility, and efforts to achieve the unimpeded movement of irradiated foods in international trade. Food irradiation processing has many uses

  4. Measurement of high natural background radiation levels by TLD at Cox's Bazar coastal areas in Bangladesh

    International Nuclear Information System (INIS)

    Mollah, A.S.; Rahman, M.M.; Koddus, M.A.; Husain, S.R.; Malek, M.A.

    1987-01-01

    High natural background radiation levels at the Cox's Bazar coastal areas in Bangladesh were measured by LiF (TLD-100) dosemeters. The dose rates varied from 2621 to 35391 μGy.y -1 with a mean of 11968 μGy.y -1 . The average dose rate is found to significantly higher than the world average value. In order to formulate appropriate guidelines for radiation protection of the population in this area, the necessary recommendations are described. (author)

  5. Environmental radiation measurements using TLD in and around AERE, Dhaka

    International Nuclear Information System (INIS)

    Mollah, A.S.; Husain, S.R.; Rahman, M.M.

    1986-01-01

    The external background radiation level in and around the Atomic Energy Research Establishment (AERE) in Dhaka has been measured. The measurements were performed using lithium fluoride (LiF) thermoluminescence dosemeters (TLD-100) at 32 locations, all one metre above the ground. The annual average dose rate measured in the AERE environs was 1.74+-0.23 mGy.y -1 in air, based on analysis of thermoluminescence dosemeter data collected from 1982 to 1984. (author)

  6. Influence of CuO content on the structure of lithium fluoroborate glasses: Spectral and gamma irradiation studies.

    Science.gov (United States)

    Abdelghany, A M; ElBatal, H A; EzzElDin, F M

    2015-10-05

    Glasses of lithium fluoroborate of the composition LiF 15%-B2O3 85% with increasing CuO as added dopant were prepared and characterized by combined optical and FTIR spectroscopy before and after gamma irradiation. The optical spectrum of the undoped glass reveals strong UV absorption with two distinct peaks at about 235 and 310 nm and with no visible bands. This strong UV absorption is related to the presence of unavoidable trace iron impurity (Fe(3+)) within the materials used for the preparation of this glass. After irradiation, the spectrum of the undoped glass shows a decrease of the intensity of the UV bands together with the resolution of an induced visible broad band centered at about 520 nm. The CuO doped glasses reveal the same UV absorption beside a very broad visible band centered at 780 nm and this band shows extension and splitting to several component peaks with higher CuO contents. Upon gamma irradiation, the spectra of all CuO-doped glasses reveal pronounced decrease of their intensities. The response of irradiation on the studied glasses is correlated with suggested photochemical reactions together with some shielding effect of the copper ions. The observed visible band is related to the presence of copper as distorted octahedral Cu(2+) ions. Infrared absorption spectra of the prepared glasses show repetitive characteristic triangular and tetrahedral borate units similar to that published from alkali or alkaline earth oxides B2O3 glasses. A suggested formation of (BO3/2F) tetrahedral units is advanced through action of LiF on B2O3 and these suggested units showing the same position and number as BO4 tetrahedra. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Containers in food irradiation

    International Nuclear Information System (INIS)

    Bolumen, S.; Espinosa, R.

    1997-01-01

    The preservation of food by irradiation is promising technology which increases industrial application. Packaging of irradiated foods is an integral part of the process. Judicious selection of the package material for successful trade is essential. In this paper is presented a brief review of important aspects of packaging in food irradiation [es

  8. iTRAQ-based proteomic analysis of LI-F type peptides produced by Paenibacillus polymyxa JSa-9 mode of action against Bacillus cereus.

    Science.gov (United States)

    Han, Jinzhi; Gao, Peng; Zhao, Shengming; Bie, Xiaomei; Lu, Zhaoxin; Zhang, Chong; Lv, Fengxia

    2017-01-06

    LI-F type peptides (AMP-jsa9) produced by Paenibacillus polymyxa JSa-9 are a group of cyclic lipodepsipeptide antibiotics that exhibit a broad antimicrobial spectrum against Gram-positive bacteria and filamentous fungi, especially Bacillus cereus and Fusarium moniliforme. In this study, to better understand the antibacterial mechanism of AMP-jsa9 against B. cereus, the ultrastructure of AMP-jsa9-treated B. cereus cells was observed by both atomic force microscopy and transmission electron microscopy, and quantitative proteomic analysis was performed on proteins extracted from treated and untreated bacterial cells by using isobaric tag for relative and absolute quantitation (iTRAQ) labeling and LC-MS/MS analysis to access differentially expressed proteins. Furthermore, multiple experiments were conducted to validate the results of the proteomic analysis, including determinations of ATP, NAD (+) H, NADP (+) H, reactive oxygen species (ROS), the activities of catalase (CAT) and superoxide dismutase (SOD), and the relative expression of target genes by quantitative real-time PCR. Bacterial cells exposed to AMP-jsa9 showed irregular surfaces with bleb projections and concaves; we hypothesize that AMP-jsa9 penetrated the cell wall and was anchored on the cytoplasmic membrane and that ROS accumulated in the cell membrane after treatment with AMP-jsa9, modulating the bacterial membrane properties and increasing membrane permeability. Consequently, the blebs were formed on the cell wall by the impulsive force of the leakage of intercellular contents. iTRAQ-based proteomic analysis detected a total of 1317 proteins, including 176 differentially expressed proteins (75 upregulated (fold >2) and 101 downregulated (fold AMP-jsa9 action against B. cereus can be summarized as: (i) inhibition of bacterial sporulation, thiamine biosynthesis, energy metabolism, DNA transcription and translation, and cell wall biosynthesis, through direct regulation of protein levels; and (ii

  9. Radiation dose in critical organs due to non-coplanar irradiation of the pituitary gland

    International Nuclear Information System (INIS)

    Schulte, R.W.M.; Rittmann, K.L.; Meinass, H.J.; Rennicke, P.

    1996-01-01

    In order to estimate the somatic and genetic risk associated with a non-coplanar linac-based radiation technique of the pituitary gland, systematic secondary-dose measurements in a phantom and sample measurements of the dose near critical organs of patients were performed. For measurements of the dose outside the primary radiation field an acrylic-PVC phantom was used which was irradiated with a single field (4x4 cm 2 ). Eight patients with pituitary tumors were treated isocentrically with a combination of sagittal and transverse rotational arcs. To measure the dose in critical organs, LiF thermoluminescence dosimeters (TLD) in chip form were placed onto 1 eyelid, the skin over the thyroid, and the patient's clothes covering the region of breasts and ovaries of female patients and the testicles of male patients. Measurements were performed for all patients during 1 sagittal irradiation and for the majority of patients during 1 transverse irradiation. The phantom measurements demonstrated that the secondary dose measured on the patients surface can be considered as a good approximation for the dose in adjacent organs. The median dose in critical organs for sagittal irradiation was in the range of 25.8 mGy (eyes) to 1.9 mGy (testicles), and for transverse irradiation in the range of 23.3 mGy (eyes) to 1.3 mGy (testicles). The ratio of median organ doses for sagittal and transverse irradiation was 2.1 for the thyroid gland, 1.1 for the eyes, and 1.5 for the other organs. The dose in critical organs due to non-coplanar irradiation of the pituitary gland is only a small fraction of the dose delivered to the reference point of the planning target volume. The risk of a radiation-induced tumor and a genetic consequence associated with these small doses is generally less than 1% and 0.1%, respectively. (orig./MG) [de

  10. Irradiation of foodstuffs

    International Nuclear Information System (INIS)

    Sjoeberg, A.M.

    1993-01-01

    Foodstuffs are irradiated to make them keep better. The ionizing radiation is not so strong as to cause radioactivity in the foodstuffs. At least so far, irradiation has not gained acceptance among consumers, although it has been shown to be a completely safe method of preservation. Irradiation causes only slight chemical changes in food. What irradiation does, however, is to damage living organisms, such as bacteria, DNA and proteins, thereby making the food keep longer. Irradiation can be detected from the food afterwards; thus it can be controlled effectively. (orig.)

  11. Study of some characteristic dosimetric of the LIF:Mg, You (JR1152C) for their employment as environmental dosemeter

    International Nuclear Information System (INIS)

    Molina Perez, D.; Diaz Bernal, E.; Prendes Alonso, M.

    1998-01-01

    As the interest grows in knowing the effects on the health of the drops dose of natural or artificial radiation, it is made but necessary a system dosimetric able to measure those dose levels accurately. P but of twenty years the dosemeters thermoluminescent (TL) they have constituted a simple and beautiful method for such mensurations. In the work the rehearsals of homogeneity, reproducibility, line lay, detection threshold, auto irradiation, residual, fading and angular dependence are described. The results demonstrate that the dosemeter satisfies the main requirements to be an employee in the environmental monitoring

  12. Detector for the FSD Fourier-diffractometer based on ZnS(Ag)/6LiF scintillation screen and wavelength shifting fibers readout

    International Nuclear Information System (INIS)

    Kuz'min, E.S.; Balagurov, A.M.; Bokuchava, G.D.; Zhuk, V.V.; Kudryashev, V.A.; Bulkin, A.P.; Trunov, V.A.

    2001-01-01

    At the IBR-2 pulsed reactor (FLNP, JINR, Dubna), a specialized time-of-flight instrument Fourier-Stress-Diffractometer (FSD) intended for the measurement of internal stresses in bulk samples by using high-resolution neutron diffraction is under construction. One of the main components of the diffractometer is a new-type detector with combined electronic - geometrical focusing uniting a large solid angle and a small geometry contribution to the instrumental resolution. The first two modules of the detector, based on scintillation screen ZnS(Ag)/ 6 LiF with wavelength shifting fibers readout have been developed and tested. The design of the detector and associated electronics are described. The method of time focusing surface approximation, using the screen flexibility is proposed. Characteristics of the tested modules in comparison with a detector of the previous generation are presented and advantages of the new detector design for high-resolution diffractometry are discussed

  13. Standoff detection of bioaerosols over wide area using a newly developed sensor combining a cloud mapper and a spectrometric LIF lidar

    Science.gov (United States)

    Buteau, Sylvie; Simard, Jean-Robert; Roy, Gilles; Lahaie, Pierre; Nadeau, Denis; Mathieu, Pierre

    2013-10-01

    A standoff sensor called BioSense was developed to demonstrate the capacity to map, track and classify bioaerosol clouds from a distant range and over wide area. The concept of the system is based on a two steps dynamic surveillance: 1) cloud detection using an infrared (IR) scanning cloud mapper and 2) cloud classification based on a staring ultraviolet (UV) Laser Induced Fluorescence (LIF) interrogation. The system can be operated either in an automatic surveillance mode or using manual intervention. The automatic surveillance operation includes several steps: mission planning, sensor deployment, background monitoring, surveillance, cloud detection, classification and finally alarm generation based on the classification result. One of the main challenges is the classification step which relies on a spectrally resolved UV LIF signature library. The construction of this library relies currently on in-chamber releases of various materials that are simultaneously characterized with the standoff sensor and referenced with point sensors such as Aerodynamic Particle Sizer® (APS). The system was tested at three different locations in order to evaluate its capacity to operate in diverse types of surroundings and various environmental conditions. The system showed generally good performances even though the troubleshooting of the system was not completed before initiating the Test and Evaluation (T&E) process. The standoff system performances appeared to be highly dependent on the type of challenges, on the climatic conditions and on the period of day. The real-time results combined with the experience acquired during the 2012 T & E allowed to identify future ameliorations and investigation avenues.

  14. Sensory properties of irradiated foods

    International Nuclear Information System (INIS)

    Plestenjak, A.

    1997-01-01

    Food irradiation is a simple and effective preservation technique. The changes caused by irradiation depend on composition of food, on the absorbed dose, the water content and temperature during and after irradiation. In this paper the changes of food components caused by irradiation, doses for various food irradiation treatments, foods and countries where the irradiation is allowed, and sensory properties of irradiated food are reviewed

  15. Irradiation - who needs it?

    International Nuclear Information System (INIS)

    Scoular, C.

    1994-01-01

    In this paper the public's attitudes to the irradiation of food to ensure it is bacteria free and to prolong shelf-life are considered. The need to label irradiated food and to educate the public about its implications are emphasised. The opinions of the large food retailers who maintain that high standards in food processing, hygiene and refrigeration eliminate the need for food irradiation are discussed. (UK)

  16. Identification of irradiated chicken

    International Nuclear Information System (INIS)

    Spiegelberg, A.; Heide, L.; Boegl, K.W.

    1990-01-01

    Frozen chicken and chicken parts were irradiated at a dose of 5 kGy with Co-60. The irradiated chicken and chicken parts were identified by determination of three radiation-induced hydrocarbons from the lipid fraction. Isolation was carried out by high-vacuum distillation with a cold-finger apparatus. The detection of the hydrocarbons was possible in all irradiated samples by gaschromatography/mass spectrometry. (orig.) [de

  17. Food irradiation - now

    International Nuclear Information System (INIS)

    Basson, R.A.

    1989-01-01

    Food irradiation technology in South Africa is about to take its rightful place next to existing food preservation methods in protecting food supplies. This is as a result of several factors, the most important of which is the decision by the Department of Health and Population Development to introduce compulsory labelling of food irradiation. The factors influencing food irradiation technology in South Africa are discussed

  18. Development of blood irradiators

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    This project is designed to improve the techniques of blood irradiation through the development of improved and portable blood irradiators. A portable blood irradiator, consisting of a vitreous carbon body and thulium-170 radiation source, was attached to dogs via a carotid-jugular shunt, and its effects on the immune system measured. The device has demonstrated both significant suppression of circulating lymphocytes and prolonged retention of skin allografts

  19. Spatially resolved analyses of uranium species using a coupled system made up of confocal laser-scanning microscopy (CLSM) and laser induced fluorescence spectroscopy (LIFS); Ortsaufgeloeste Analyse von Uranspezies mittels einem Gekoppelten System aus Konfokaler Laser-Scanning Mikroskopie (CLSM) und Laser Induzierter Fluoreszenzspektroskopie (LIFS)

    Energy Technology Data Exchange (ETDEWEB)

    Brockmann, S. [Verein fuer Kernverfahrenstechnik und Analytik Rossendorf e.V. (VKTA), Dresden (Germany); Grossmann, K.; Arnold, T. [Helmholtz-Zentrum Dresden-Rossendorf e.V. (Germany). Inst. fuer Ressourcenoekologie

    2014-01-15

    The fluorescent properties of uranium when excited by UV light are used increasingly for spectroscope analyses of uranium species within watery samples. Here, alongside the fluorescent properties of the hexavalent oxidation phases, the tetra and pentavalent oxidation phases also play an increasingly important role. The detection of fluorescent emission spectrums on solid and biological samples using (time-resolved) laser induced fluorescence spectroscopy (TRLFS or LIFS respectively) has, however, the disadvantage that no statements regarding the spatial localisation of the uranium can be made. However, particularly in complex, biological samples, such statements on the localisation of the uranium enrichment in the sample are desired, in order to e.g. be able to distinguish between intra and extra-cellular uranium bonds. The fluorescent properties of uranium (VI) compounds and minerals can also be used to detect their localisation within complex samples. So the application of fluorescent microscopic methods represents one possibility to localise and visualise uranium precipitates and enrichments in biological samples, such as biofilms or cells. The confocal laser-scanning microscopy (CLSM) is especially well suited to this purpose. Coupling confocal laser-scanning microscopy (CLSM) with laser induced fluorescence spectroscopy (LIFS) makes it possible to localise and visualise fluorescent signals spatially and three-dimensionally, while at the same time being able to detect spatially resolved, fluorescent-spectroscopic data. This technology is characterised by relatively low detection limits from up to 1.10{sup -6} M for uranium (VI) compounds within the confocal volume. (orig.)

  20. Irradiation of food

    International Nuclear Information System (INIS)

    Lindell, B.; Danielsson-Tham, M.L.; Hoel, C.

    1983-01-01

    A committee has on instructions from the swedish government made an inquiry into the possible effects on health and working environment from irradition of food. In this report, a review is presented on the known positiv and negative effects of food irradiation Costs, availabilty, shelf life and quality of irradiated food are also discussed. According to the report, the production of radiolysis products during irradiation is not easily evaluated. The health risks from irradiation of spices are estimated to be lower than the risks associated with the ethenoxid treatment presently used. (L.E.)

  1. Gamma irradiation devices

    International Nuclear Information System (INIS)

    Foeldiak, Gabor; Stenger, Vilmos.

    1983-01-01

    The main parameters and the preparation procedures of the gamma radiation sources frequently applied for irradiation purposes are discussed. In addition to 60 Co and 137 Cs sources also the nuclear power plants offer further opportunities: spent fuel elements and products of certain (n,γ) reactions can serve as irradiation sources. Laboratory scale equipments, pilot plant facilities for batch or continuous operation, continuous industrial irradiators and special multipurpose, mobile and panorama type facilities are reviewed including those in Canada, USA, India, the Soviet Union, Hungary, UK, Japan and Australia. For irradiator design the source geometry dependence of the spatial distribution of dose rates can be calculated. (V.N.)

  2. Immunocytoadherence and sublethal irradiation

    International Nuclear Information System (INIS)

    Beaumariage, M.L.; Hiesche, K.; Revesz, L.; Haot, J.

    1975-01-01

    In sublethally irradiated CBA mice, the relative and absolute numbers of spontaneous rosette forming cells against sheep erythrocytes are markedly decreased in bone marrow. The decrease of the absolute number of spontaneous RFC is also important in the spleen in spite of an increase of the RFC relative number above the normal values between the 8th and 12th day after irradiation. The graft of normal bone marrow cells immediately after irradiation or the shielding of a medullary area during irradiation promotes the recovery of the immunocytoadherence capacity of the bone marrow cells but not of the spleen cells [fr

  3. Fluorescence of irradiated hydrocarbons

    International Nuclear Information System (INIS)

    Gulis, I.G.; Evdokimenko, V.M.; Lapkovskij, M.P.; Petrov, P.T.; Gulis, I.M.; Markevich, S.V.

    1977-01-01

    A visible fluorescence has been found out in γ-irradiated aqueous of carbohydrates. Two bands have been distinguished in fluorescence spectra of the irradiated solution of dextran: a short-wave band lambdasub(max)=140 nm (where lambda is a wave length) at lambdasub(β)=380 nm and a long-wave band with lambdasub(max)=540 nm at lambdasub(β)=430 nm. A similar form of the spectrum has been obtained for irradiated solutions of starch, amylopectin, lowmolecular glucose. It has been concluded that a macromolecule of polysaccharides includes fluorescent centres. A relation between fluorescence and α-oxiketon groups formed under irradiation has been pointed out

  4. Planning of irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Caha, A; Krystof, V [Vyzkumny Ustav Klinicke a Experimentalni Onkologie, Brno (Czechoslovakia)

    1979-07-01

    The principles are discussed of the planning of irradiation, ie., the use of the various methods of location of a pathological focus and the possibility of semiautomatic transmission of the obtained data on a two-dimensional or spatial model. An efficient equipment is proposed for large irradiation centres which should cooperate with smaller irradiation departments for which also a range of apparatus is proposed. Irradiation planning currently applied at the Research Institute of Clinical and Experimental Oncology in Brno is described. In conclusion, some of the construction principles of semi-automatic operation of radiotherapy departments are discussed.

  5. Food irradiation: fiction and reality

    International Nuclear Information System (INIS)

    1991-01-01

    The International Consultative Group on Food Irradiation (IGCFI), sponsored by World Health Organization (WHO), Food and Agriculture Organization (FAO) and the International Atomic Energy Agency (IAEA), with the intention to provide to governments, especially those of developing countries, scientifically correct information about food irradiation, decided to organize a file and questions of general public interest. The document is composed by descriptive files related with the actual situation and future prospective, technical and scientific terms, food irradiation and the radioactivity, chemical transformations in irradiated food, genetic studies, microbiological safety of irradiated food, irradiation and harmlessness, irradiation and additives, packing, irradiation facilities control, process control, irradiation costs and benefits as well as consumers reaction

  6. In vivo thermoluminescent dosimetry on the radiotherapy of limphomas, esophageal and uterine tumour

    International Nuclear Information System (INIS)

    Morales, F.C.

    1982-01-01

    A comparative study between dose distribution in pre-selected tumoral plans was established through measurements with thermoluminescent dosimeters and calculations based on 'scatter-air-ratios' properties, isodose curves and collected data. Clinic dosimetry was performed 'in vivo' with LiF dosimeters (TLD-100) and LiF Teflon (1 mm theta, 6 mm lenght). Patients with Hodgkin's disease, carcinoma of the esophagus and of the uterine cervix were selected. Telecobaltherapy was used for these groups of neoplasic conditions. (M.A.C.) [pt

  7. Facts about food irradiation: Chemical changes in irradiated foods

    International Nuclear Information System (INIS)

    1991-01-01

    This fact sheet addresses the safety of irradiated food. The irradiation process produces very little chemical change in food, and laboratory experiments have shown no harmful effects in animals fed with irradiated milk powder. 3 refs

  8. Modelling property changes in graphite irradiated at changing irradiation temperature

    CSIR Research Space (South Africa)

    Kok, S

    2011-01-01

    Full Text Available A new method is proposed to predict the irradiation induced property changes in nuclear; graphite, including the effect of a change in irradiation temperature. The currently used method; to account for changes in irradiation temperature, the scaled...

  9. Irradiation of foodstuffs

    International Nuclear Information System (INIS)

    Bugyaki, L.

    1977-01-01

    The author studies the criteria for the harmlessness of irradiation as a food-preservation process. The glucose and proteins of bacto-tryptone, irradiated at 5 Mrads, do not increase the Escherichia Coli C 600 lysogenous bacteriophages, compared to the induction produced by direct irradiation of the strain or to the exposition to nitrogenous yperite. The possible mutagenic effect is therefore different. Wheat flour freshly irradiated at 5 Mrads shows physico-chemical changes. When given to mice as 50% of their ration, it leads to a higher incidence of tumours and a greater number of meiotic chromosome alteration (besides some discreet physio-pathological changes in fertility and longevity). Immunoelectrophoresis in agar or agarose gel does not allow any detection of irradiation of meat, fish or eggs. A vertical electrophoresis in starch gel can lead to a differentiation between frozen or chilled meat and the one that is irradiated at 0.5 or 5 Mrads, but the same thing can't be said for fish or eggs. Lastly an irradiated mushroom shows every sign of freshness but, when planted in a suitable medium, its cuttings do not present any cell proliferation which could give a rapid and simple method of detecting the irradiation. (G.C.)

  10. Materials modified by irradiation

    International Nuclear Information System (INIS)

    Chmielewski, A.G.

    2007-01-01

    Application of radiation in pharmaceutical sciences and cosmetology, polymer materials, food industry, environment, health camre products and packing production is described. Nano-technology is described more detailed, because it is less known as irradiation using technology. Economic influence of the irradiation on the materials value addition is shown

  11. Special irradiation techniques

    International Nuclear Information System (INIS)

    Colomez, Gerard; Veyrat, J.F.

    1981-01-01

    Irradiation trials conducted on materials-testing reactors should provide a better understanding of the phenomena which characterize the working and evolution in time of electricity-generating nuclear reactors. The authors begin by outlining the objectives behind experimental irradiation (applied to the various nuclear chains) and then describe the special techniques deployed to achieve these objectives [fr

  12. Food irradiation: the facts

    International Nuclear Information System (INIS)

    Webb, Tony; Lang, Tim

    1987-01-01

    The London Food Commission summarizes its concerns about the use of food irradiation in the U.K. resulting from its working group surveys of general public opinion, trading standard officers and the food industry in the U.K., and from experience in countries already permitting irradiation to a variety of foods. (U.K.)

  13. Progress in food irradiation

    Energy Technology Data Exchange (ETDEWEB)

    1982-01-01

    The volume contains reports from 19 countries on the state of the project in the field of food irradiation (fruit, vegetables, meat, spices) by means of gamma rays. The tests ran up to 1982. Microbiological radiosensitivity and mutagenicity tests provide a yard stick for irradiation efficiency.

  14. Food irradiation: the facts

    International Nuclear Information System (INIS)

    Hamilton, M.

    1990-01-01

    The author explains in simple question and answer form what is entailed in the irradiation of food and attempts to dispel some of the anxieties surrounding the process. Benefits and limitations, controls, labelling safety, and tests for the detection of the use irradiation in food preparation are some of the topics dealt with in outline. (author)

  15. Perspective on food irradiation

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    Recent US Food and Drug Administration approval of irradiation treatment for fruit, vegetables and pork has stimulated considerable discussion in the popular press on the safety and efficacy of irradiation processing of food. This perspective is designed to summarize the current scientific information available on this issue

  16. Food Irradiation in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Kawabata, T.

    1981-09-15

    Since 1967 research activities on food irradiation in Japan have been carried out under the National Food Irradiation Programme by the Japanese Atomic Energy Commission. The programme has been concentrated on the technological and economical feasibility and wholesomeness testings of seven irradiated food items of economic importance to the country, i.e. potatoes, onions, wheat, rice, 'kamaboko' (fish-paste products), 'Vienna' sausages and mandarin oranges. By now most studies, including wholesomeness testings of these irradiated food items, have been completed. In Japan, all foods or food additives for sale are regulated by the Food Sanitation Law enforced in 1947. Based on studies made by the national programme, irradiated potatoes were given 'unconditional acceptance' for human consumption in 1972. At present, irradiated potatoes are the only food item which has so far been approved by the Minister of Health and Welfare. Unless the Minister of Health and Welfare has declared that items are not harmful to human health on obtaining comments from the Food Sanitation Investigation Council, no irradiated food can be processed or sold. In addition, the import of irradiated foodstuffs other than potatoes from foreign countries is prohibited by law.

  17. Post irradiation conical keratosis

    International Nuclear Information System (INIS)

    Vestey, J.P.; Hunter, J.A.A.; Mallet, R.B.; Rodger, A.

    1989-01-01

    The authors have recently seen 3 patients affected by a widespread eruption of minute keratoses confined to areas of irradiated skin with clinical and histologial features of which they have been unable to find previous literary descriptions. A fourth patient with similar clinical and histopathological features occurring after exposure only to actinic irradiation is described. (author)

  18. Post irradiation conical keratosis

    Energy Technology Data Exchange (ETDEWEB)

    Vestey, J.P.; Hunter, J.A.A. (Royal Infirmary, Edinburgh (UK)); Mallet, R.B. (Westminster Hospital, London (UK)); Rodger, A. (Western General Hospital, Edinburgh (UK))

    1989-03-01

    The authors have recently seen 3 patients affected by a widespread eruption of minute keratoses confined to areas of irradiated skin with clinical and histologial features of which they have been unable to find previous literary descriptions. A fourth patient with similar clinical and histopathological features occurring after exposure only to actinic irradiation is described. (author).

  19. Irradiation damage in superconductors

    International Nuclear Information System (INIS)

    Quere, Y.

    1989-01-01

    Most superconductors are quite sensitive to irradiation defects. Critical temperatures may be depressed, critical currents may be increased, by irradiation, but other behaviours may be encountered. In compounds, the sublattice in which defects are created is of significant importance. 24 refs

  20. Food preservation by irradiation

    International Nuclear Information System (INIS)

    Labots, H.; Huis in 't Veld, G.J.P.; Verrips, C.T.

    1985-01-01

    After a review of several methods for the preservation of food and the routes of food infections, the following chapters are devoted to the preservation by irradiation. Applications and legal aspects of food irradiation are described. Special reference is made to the international situation. (Auth.)

  1. Food irradiation control

    International Nuclear Information System (INIS)

    Ley, F.J.

    1988-01-01

    A brief review is given of the control and monitoring of food irradiation with particular emphasis on the UK situation. After describing legal aspects, various applications of food irradiation in different countries are listed. Other topics discussed include code of practice for general control for both gamma radiation and electron beam facilities, dose specification, depth dose distribution and dosimetry. (U.K.)

  2. Uniformly irradiated polymer film

    International Nuclear Information System (INIS)

    Fowler, S.L.

    1979-01-01

    Irradiated film having substantial uniformity in the radiation dosage profile is produced by irradiating the film within a trough having lateral deflection blocks disposed adjacent the film edges for deflecting electrons toward the surface of the trough bottom for further deflecting the electrons toward the film edge

  3. NUCLEAR HEATING IN LIF DOSEMETERS IN A FUSION NEUTRON FIELD, TRIAL OF DIRECT COMPARISON OF EXPERIMENTAL AND SIMULATED RESULTS.

    Science.gov (United States)

    Pohorecki, Wladyslaw; Obryk, Barbara

    2017-09-29

    The results of nuclear heating measured by means of thermoluminescent dosemeters (TLD-LiF) in a Cu block irradiated by 14 MeV neutrons are presented. The integral Cu experiment relevant for verification of copper nuclear data at neutron energies characteristic for fusion facilities was performed in the ENEA FNG Laboratory at Frascati. Five types of TLDs were used: highly photon sensitive LiF:Mg,Cu,P (MCP-N), 7LiF:Mg,Cu,P (MCP-7) and standard, lower sensitivity LiF:Mg,Ti (MTS-N), 7LiF:Mg,Ti (MTS-7) and 6LiF:Mg,Ti (MTS-6). Calibration of the detectors was performed with gamma rays in terms of air-kerma (10 mGy of 137Cs air-kerma). Nuclear heating in the Cu block was also calculated with the use of MCNP transport code Nuclear heating in Cu and air in TLD's positions was calculated as well. The nuclear heating contribution from all simulated by MCNP6 code particles including protons, deuterons, alphas tritons and heavier ions produced by the neutron interactions were calculated. A trial of the direct comparison between experimental results and results of simulation was performed. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  4. Irradiation Creep in Graphite

    Energy Technology Data Exchange (ETDEWEB)

    Ubic, Rick; Butt, Darryl; Windes, William

    2014-03-13

    An understanding of the underlying mechanisms of irradiation creep in graphite material is required to correctly interpret experimental data, explain micromechanical modeling results, and predict whole-core behavior. This project will focus on experimental microscopic data to demonstrate the mechanism of irradiation creep. High-resolution transmission electron microscopy should be able to image both the dislocations in graphite and the irradiation-induced interstitial clusters that pin those dislocations. The team will first prepare and characterize nanoscale samples of virgin nuclear graphite in a transmission electron microscope. Additional samples will be irradiated to varying degrees at the Advanced Test Reactor (ATR) facility and similarly characterized. Researchers will record microstructures and crystal defects and suggest a mechanism for irradiation creep based on the results. In addition, the purchase of a tensile holder for a transmission electron microscope will allow, for the first time, in situ observation of creep behavior on the microstructure and crystallographic defects.

  5. Irradiation of goods

    International Nuclear Information System (INIS)

    Lunt, R.E.

    1987-01-01

    Mechanical handling apparatus is adapted to handle goods, such as boxed fruit, during a process of irradiation, in palletized form. Palletized goods are loaded onto wheeled vehicles in a loading zone. Four vehicles are wheeled on a track into an irradiation zone via a door in a concrete shield. The vehicles are arranged in orthogonal relationship around a source of square section. Turntables are positioned at corners of the square shaped rail truck around the source selectively to turn the vehicles to align then with track sections. Mechanical manipulating devices are positioned in the track sections opposed to sides of the source. During irradiation, the vehicles and their palletized goods are cylically moved toward the source to offer first sides of the goods for irradiation and are retraced from the source and are pivoted through 90 0 to persent succeeding sides of the goods for irradiation

  6. Irradiation of packaged food

    International Nuclear Information System (INIS)

    Kilcast, D.

    1990-01-01

    Food irradiation is used to improve the safety of food by killing insects and microorganisms, to inhibit sprouting in crops such as onions and potatoes and to control ripening in agricultural produce. In order to prevent re-infestation and re-contamination it is essential that the food is suitably packed. Consequently, the packaging material is irradiated whilst in contact with the food, and it is important that the material is resistant to radiation-induced changes. In this paper the nature of the irradiation process is reviewed briefly, together with the known effects of irradiation on packaging materials and their implications for the effective application of food irradiation. Recent research carried out at the Leatherhead Food RA on the possibility of taint transfer into food is described. (author)

  7. Issues in food irradiation

    International Nuclear Information System (INIS)

    Mills, S.

    1987-04-01

    This discussion paper has two goals: first, to raise public awareness of food irradiation, an emerging technology in which Canada has the potential to build a new industry, mainly oriented to promising overseas markets; and second, to help build consensus among government and private sector decision makers about what has to be done to realize the domestic and export potential. The following pages discuss the potential of food irradiation; indicate how food is irradiated; outline the uses of food irradiation; examine questions of the safety of the equipment and both the safety and nutritional value of irradiated food; look at international commercial developments; assess the current and emerging domestic scene; and finally, draw some conclusions and offer suggestions for action

  8. Extracorporeal irradiation -Physicist perspective

    International Nuclear Information System (INIS)

    Vijayaprabhu, N.; Saravanan, K.S.; Gunaseelan; Vivekanandam, S.; Reddy, K.S.; Parthasarathy; Mourougan, S.; Elangovan, K.

    2008-01-01

    Extracorporeal irradiation (ECI) involves irradiation of body tissues, particularly malignant bones of the extremities, outside the body. This involves en bloc resection of the tumour, extracorporeal irradiation of the bone segment with a single dose of 50 Gy or more, and reimplantation of the irradiated bone with fixation devices. Bone tumours like Ewing's Sarcoma, Chondrosarcoma and Oesteosarcoma; in the involved sites like femur, tibia, humerus, ilium and sacrum can be treated with ECI. The reimplanted bone simply acts as a framework for appositional bone growth from surrounding healthy bones. The conventional indications for postoperative irradiation are still applied. The major advantages of ECI are the precise anatomic fit of the reimplanted bone segment, preservation of joint mobility and its potential in avoiding the growth discrepancy commonly seen in prosthetic replacement. The use of ECI was first described in 1968 and practiced in Australia since 1996. In our center, we have completed six ECIs

  9. Patient dose, gray level and exposure index with a computed radiography system

    Science.gov (United States)

    Silva, T. R.; Yoshimura, E. M.

    2014-02-01

    Computed radiography (CR) is gradually replacing conventional screen-film system in Brazil. To assess image quality, manufactures provide the calculation of an exposure index through the acquisition software of the CR system. The objective of this study is to verify if the CR image can be used as an evaluator of patient absorbed dose too, through a relationship between the entrance skin dose and the exposure index or the gray level values obtained in the image. The CR system used for this study (Agfa model 30-X with NX acquisition software) calculates an exposure index called Log of the Median (lgM), related to the absorbed dose to the IP. The lgM value depends on the average gray level (called Scan Average Level (SAL)) of the segmented pixel value histogram of the whole image. A Rando male phantom was used to simulate a human body (chest and head), and was irradiated with an X-ray equipment, using usual radiologic techniques for chest exams. Thermoluminescent dosimeters (LiF, TLD100) were used to evaluate entrance skin dose and exit dose. The results showed a logarithm relation between entrance dose and SAL in the image center, regardless of the beam filtration. The exposure index varies linearly with the entrance dose, but the angular coefficient is beam quality dependent. We conclude that, with an adequate calibration, the CR system can be used to evaluate the patient absorbed dose.

  10. Dosimetry characteristics of thermoluminescent Li2B4O7:Cu phosphor

    International Nuclear Information System (INIS)

    Lakshmanan, A.R.; Chandra, B.; Bhatt, R.C.

    1981-01-01

    Preliminary investigations on the radiation dosimetry characteristics of Li 2 B 4 O 7 :Cu TLD phosphor are described. The major TL peak in this phosphor occurs at 230 0 C and its TL sensitivity to gamma radiation is two to three times higher than that of LiF TLD-100. The gamma dose Vs TL response of this peak is linear (within +- 20%) in the dose range 0.3 mGy-3x10 2 Gy above which saturation sets in. Its TL response for 30 keV X-rays is about 20% lower than that for 60 Coγ-rays. On annealing at 300 0 C, the phosphor gets slightly discoloured (brownish). This results in the reduction of the TL sensitivity by about 20 - 25%. The phosphor does not exhibit either sensitization or damage even after a gamma dose of 10 3 Gy. The TL emission spectrum has a broad peak at 360 nm. The intrinsic TL sensitivity of virgin Li 2 B 4 O 7 :Cu to 253.7 nm UV radiation is nearly 50 times higher than that of CaSO 4 :Dy. The post-irradiation fading in Li 2 B 4 O 7 :Cu at ambient temperature and humidity conditions is, however, less than 10% in 17 days. These characteristics indicate that Li 2 B 4 O 7 :Cu is a promising phosphor for ionizing as well as UV radiation dosimetry. (author)

  11. Improving TL dosimetry for external radiotherapy

    International Nuclear Information System (INIS)

    Bustos, S.R.; Velez, G.; Rubio, M.

    1998-01-01

    Full text: In vivo thermoluminescence dosimetry (TLD) has always been one of the most accurate dosimetry method for external radiotherapy control, but the delay in the response is a well know drawback when it is applied. In this work we show some improvements and demonstrate that keeping the precision and accuracy of this technique, it is possible to obtain a response in few hours. Harshaw 4000 TL reader and LiF TLD-100 dosimeters, chips (3,1 x 3,1 x 0,9 mm 3 ) and rods (1 x 1 x 6 mm 3 ) have been used. The thermal treatment necessary to reuse the TLD is only 1h at 400 degree C, by using a glow curve analyser developed at the Ciemat (Spain), that allows a complete, prompt and precise identification of the individuals peaks. The dosimeters are periodically and individually calibrated. We also have study the factors contributing to the relation TL-dose like linearity, energy correction, directional response and fading. All those results are included into an Excel worksheet which automatically give us the dose resulting from the TL reading (peaks areas 4 and 5). The obtained uncertainty is better than 5%. The TLD already irradiated in radiotherapy institutions distant 30-40 Km from our centre can be read and analysed in about 3-4 hours. These facts render our methods rapid and allow a better control of radiotherapy treatment even if it is bi-fractionated. (author) [es

  12. Two-dimensional LIF measurements of humidity and OH density resulting from evaporated water from a wet surface in plasma for medical use

    International Nuclear Information System (INIS)

    Yagi, Ippei; Ono, Ryo; Oda, Tetsuji; Takaki, Koichi

    2015-01-01

    In plasma medicine, plasma is applied to a wet surface and is often accompanied by dry-gas flow. The dry-gas flow affects water evaporation from the wet surface and influences production of reactive species derived from water vapor, such as OH radicals. In this study, the effect of the dry-gas flow on two-dimensional distributions of humidity and OH radical density are examined by measuring them using laser-induced fluorescence (LIF). First, humidity is measured when nitrogen flows from a quartz tube of 4 mm inner diameter onto distilled water and agar media from 5 mm distance. NO gas is added to the nitrogen as a tracer and humidity is obtained from the quenching rate of NO molecules measured using LIF. This measurement has a spatial resolution of 0.2 mm 3 and a temporal resolution of less than 220 ns. The two-dimensional humidity distribution shows that the dry-gas flow pushes away water vapor evaporating from the wet surface. As a result, a low-humidity region is formed near the quartz tube nozzle and a high-humidity region is formed near the wet surface. The thickness of the low-humidity region reduces with increasing gas flow rate. It is 0.1–0.5 mm for the flow rate of higher than 0.3 l min −1 . Next, the OH density is measured when a nanosecond pulsed streamer discharge is applied to a distilled water surface with dry-air flow. The OH density decreases with increasing gas flow rate due to decreased humidity. When the flow rate is lower than 0.1 l min −1 , the OH distribution is approximately uniform in the plasma region, while the humidity distribution shows a large gradient. The importance of the thin high-humidity region on the flux of reactive species onto the wet surface is discussed. (paper)

  13. Digital signal processing for a thermal neutron detector using ZnS(Ag):{sup 6}LiF scintillating layers read out with WLS fibers and SiPMs

    Energy Technology Data Exchange (ETDEWEB)

    Mosset, J.-B., E-mail: jean-baptiste.mosset@psi.ch; Stoykov, A.; Greuter, U.; Hildebrandt, M.; Schlumpf, N.

    2016-07-11

    We present a digital signal processing system based on a photon counting approach which we developed for a thermal neutron detector consisting of ZnS(Ag):{sup 6}LiF scintillating layers read out with WLS fibers and SiPMs. Three digital filters have been evaluated: a moving sum, a moving sum after differentiation and a digital CR-RC{sup 4} filter. The performances of the detector with these filters are presented. A full analog signal processing using a CR-RC{sup 4} filter has been emulated digitally. The detector performance obtained with this analog approach is compared with the one obtained with the best performing digital approach. - Highlights: • Application of digital signal processing for a SiPM-based ZnS:6LiF neutron detector. • Optimisation of detector performances with 3 different digital filters. • Comparison with detector performances with a full analog signal processing.

  14. Evaluation of NDA techniques applying to the measurement of alpha-activities in medium or low level radioactive reprocessing wastes (part 5). The development of LiF coating semiconductor detector

    Energy Technology Data Exchange (ETDEWEB)

    Hattori, Takatoshi; Ishii, Keiichiro [Central Research Inst. of Electric Power Industry, Komae, Tokyo (Japan). Komae Research Lab.

    1988-12-01

    In order to design the neutron detection system in the non-destructive assay device applying to the measurement of alpha-activity in medium or low level radioactive reprocessing wastes, we examined the property of the LiF coating semiconductor detector applying to gamma-radiation field. The sensitivity for thermal neutron of LiF coating ion implanted detector is 1.6 cps/nv, and reduced to half in about 300 R/h gamma-radiation field. Compared with the other neutron detectors, for example proportional counters, the performance of this detector is almost similar to that of them. This new detector has a merit to be possible to use a dry battery instead of a high voltage supply. (author).

  15. X-ray diffraction studies of structures of Be, Al, LiF, Fe+3%Si, Si, SiO2, KCl under dynamic pressures from 2 Gpa to 20 Gpa

    International Nuclear Information System (INIS)

    Egorov, L.A.; Barenboim, A.I.; Mokhova, V.V.; Dorohin, V.V.; Samoilov, A.I.

    1997-01-01

    Currently, the only direct method to study behaviour of solid crystal substance structures under dynamic compression is method to record X-rays diffraction pictures of crystal structures under shock compression. Thepaper presents results of X-rays diffraction measurements concerning structural parameters of shock compressed substances at pressures higher than Hugoniot elastic limit (Be, Al, LiF, Fe+3%Si), lower than Hugoniot elastic limit (Si, SiO 2 , LiF) and in the area of pressures of phase transformation beginning (KCl, Si). Recorded states of shock-compressed substance structures demonstrate identity of structural deformations at pressures higher and lower than Hugoniot elastic limit as well as at pressures above the phase transformation point, which can be characterized as single-axial deformations. (orig.)

  16. Performance testing of personnel extremity dosimeters by Korean LiF: Mg, Cu, Na, Si TLD(KLT-300)

    International Nuclear Information System (INIS)

    Kim, J.L.; Lee, J.I.; Chang, S.Y.; Choi, H.S.; Lee, D.H.; Han, S.J.

    2005-01-01

    Full text: As the needs and opportunities for utilization of atomic energy and radiation are increasing, the related industries, medicines, environments are developing and the relevant organizations and companies are also becoming diverse. In result, the types and kinds of the radiation related to occupational environments are becoming diversified. For the whole body dosimeters, the methodology and criteria for the performance evaluation and safety regulations and laws have been prepared in some detail, but for the extremity dosimeters, those are not prepared yet in Korea. The extremity dosimeters are required when the extremity part of our body, such as hand, elbow, and arm below the elbow, the foot, knee, and leg below the knee are exposed to the radiation in specific work environments. The dosimeter irradiation conditions are clearly discriminated between the whole body exposure condition and the extremity exposure condition. By the investigation and analysis of the management status and dose evaluation methods of the extremity dosimeters for the local absorbed dose, the personnel monitoring system of the extremity dosimeter services in Korea can be diagnosed, and the performance testing criteria and procedures can be established. Therefore, this study presents the performance testing results of extremity dosimeters on the finger and arm/leg phantoms by the procedures recommended in the ANSI (American National Standard) N13.32 using KLT-300 TL materials (LiF:Mg,Cu,Nas,Si) which were developed in Korea Atomic Energy Research Institute (KAERI). The results show that the performance index for the two types of phantoms are sufficiently satisfied with the prescribed tolerance level in the all of the test categories listed in the ANSI N13.32. These results and procedures used in this study can be applicable for regulatory body to establish the standard criteria for acceptable performance and testing conditions for personnel extremity dosimeters services in the

  17. HCP track calculations in Lif:Mg,Ti: 3D modeling of the ''track – escape'' parameter

    International Nuclear Information System (INIS)

    Sattinger, D.; Sharon, A.; Horowitz, Y.S.

    2011-01-01

    The conceptual framework of the track interaction model (TIM) was conceived in the 1970s and mathematically formulated in the 1980s to describe heavy charged particle TL fluence response supralinearity. The extended track interaction model (ETIM) was developed to include saturation effects due to overlapping tracks and has been applied to both proton and alpha particle TL fluence response. One of the parameters of major importance in the TIM is the ''track – escape'' parameter, defined by N e /N w , where N e represents the number of electrons which escape the parent track during heating, and N w is the number of electrons which recombine within the parent track to produce a TL photon. Recently a first attempt was carried out to theoretically model escape parameters calculated in 2D geometry as a function of particle type and energy using trapping center (TC), luminescent center (LC) and competitive center (CC) occupation probabilities calculated from track segment radial dose distributions and optical absorption (OA) dose response. In this study, the calculations are extended to 3D geometry using a Monte Carlo approach which samples the point of creation of the charge carriers according to the TC occupation probabilities and then estimates N w by sampling the chord length to the track exterior. Charge carriers which escape the irradiated track volume contribute to N e . This more sophisticated 3D calculation of N e /N w is expected to increase the reliability of the modeling of heavy charged particle TL fluence response in the framework of the ETIM and enhance our understanding of “track effects” in Heavy Charged Particle (HCP) induced TL.

  18. Irradiation-Induced Nanostructures

    Energy Technology Data Exchange (ETDEWEB)

    Birtcher, R.C.; Ewing, R.C.; Matzke, Hj.; Meldrum, A.; Newcomer, P.P.; Wang, L.M.; Wang, S.X.; Weber, W.J.

    1999-08-09

    This paper summarizes the results of the studies of the irradiation-induced formation of nanostructures, where the injected interstitials from the source of irradiation are not major components of the nanophase. This phenomena has been observed by in situ transmission electron microscopy (TEM) in a number of intermetallic compounds and ceramics during high-energy electron or ion irradiations when the ions completely penetrate through the specimen. Beginning with single crystals, electron or ion irradiation in a certain temperature range may result in nanostructures composed of amorphous domains and nanocrystals with either the original composition and crystal structure or new nanophases formed by decomposition of the target material. The phenomenon has also been observed in natural materials which have suffered irradiation from the decay of constituent radioactive elements and in nuclear reactor fuels which have been irradiated by fission neutrons and other fission products. The mechanisms involved in the process of this nanophase formation are discussed in terms of the evolution of displacement cascades, radiation-induced defect accumulation, radiation-induced segregation and phase decomposition, as well as the competition between irradiation-induced amorphization and recrystallization.

  19. Food irradiation 2009

    International Nuclear Information System (INIS)

    Narvaiz, Patricia

    2009-01-01

    Food irradiation principles; its main applications, advantages and limitations; wholesomeness, present activities at Ezeiza Atomic Centre; research coordinated by the International Atomic Energy Agency; capacity building; and some aspects on national and international regulations, standards and commercialization are briefly described. At present 56 countries authorize the consumption of varied irradiated foods; trade is performed in 32 countries, with about 200 irradiation facilities. Argentina pioneered nuclear energy knowledge and applications in Latin America, food irradiation included. A steady growth of food industrial volumes treated in two gamma facilities can be observed. Food industry and producers show interest towards new facilities construction. However, a 15 years standstill in incorporating new approvals in the Argentine Alimentary Code, in spite of consecutive request performed either by CNEA or some food industries restricts, a wider industrial implementation, which constitute a drawback to future regional commercialization in areas such as MERCOSUR, where Brazil since 2000 freely authorize food irradiation. Besides, important chances in international trade with developed countries will be missed, like the high fresh fruits and vegetables requirements United States has in counter-season, leading to convenient sale prices. The Argentine food irradiation facilities have been designed and built in the country. Argentina produces Cobalt-60. These capacities, unusual in the world and particularly in Latin America, should be protected and enhanced. Being the irradiation facilities scarce and concentrated nearby Buenos Aires city, the possibilities of commercial application and even research and development are strongly limited for most of the country regions. (author) [es

  20. Identification of the pigment responsible for the blue fluorescence band in the laser induced fluorescence (LIF) spectra of green plants, and the potential use of this band in remotely estimating rates of photosynthesis

    International Nuclear Information System (INIS)

    Chappelle, E.W.; McMurtrey, J.E. III; Kim, M.S.

    1991-01-01

    The laser-induced fluorescence (LIF) of vegetation is being investigated in this laboratory for use as a technique for the remote detection of the effects of environmental stress upon vegetation, as well as for plant identification. The fluorescence band with a maximum at 440 nm, in conjunction with the chlorophyll bands with maxima at 685 and 740 nm, has been found to be a critical band in the development of algorithms for detecting stress, and identifying plant types. The identification of the plant constituent responsible for this band is vital to understanding the mechanism underlying its fluorescence changes in response to environmental and physiological changes. The identification was achieved as follows: The laser induced fluorescence (LIF) spectra of pure plant pigments were determined. Fluorescence bands with maxima at 420 nm, 440 nm, 490 nm, and 525 nm were observed for vitamin K 1 , reduced nicotinamide adenine dinucleotide (NADPH), beta-carotene, and riboflavin, respectively. The LIF spectra of water extracts and acetone extracts of clover leaves were also measured. It was found that the blue fluorescence band was associated with the water extract. NADPH which is a water-soluble compound, and the water extract of clover had no fluorescence after oxidation by potassium ferricyanide, while the fluorescence of water insoluble vitamin K 1 was unchanged by the oxidizing agent. It was also found that the absorption maximum of NADPH was the same as the absorption maximum of the aqueous extract of clover. The above findings indicated that the compound responsible for the blue fluorescence at 440 nm is in the reduced state and is water-soluble. It was concluded that NADPH was responsible for the blue fluorescence at 440 nm. The strong linear relationship between the fluorescence at 440 nm and the rate of photosynthesis suggests the possible use of LIF measurements in the remote estimation of photosynthetic rates. (author)