WorldWideScience

Sample records for level rtl power

  1. Multi-Level Simulated Fault Injection for Data Dependent Reliability Analysis of RTL Circuit Descriptions

    Directory of Open Access Journals (Sweden)

    NIMARA, S.

    2016-02-01

    Full Text Available This paper proposes data-dependent reliability evaluation methodology for digital systems described at Register Transfer Level (RTL. It uses a hybrid hierarchical approach, combining the accuracy provided by Gate Level (GL Simulated Fault Injection (SFI and the low simulation overhead required by RTL fault injection. The methodology comprises the following steps: the correct simulation of the RTL system, according to a set of input vectors, hierarchical decomposition of the system into basic RTL blocks, logic synthesis of basic RTL blocks, data-dependent SFI for the GL netlists, and RTL SFI. The proposed methodology has been validated in terms of accuracy on a medium sized circuit – the parallel comparator used in Check Node Unit (CNU of the Low-Density Parity-Check (LDPC decoders. The methodology has been applied for the reliability analysis of a 128-bit Advanced Encryption Standard (AES crypto-core, for which the GL simulation was prohibitive in terms of required computational resources.

  2. Principles of VLSI RTL design a practical guide

    CERN Document Server

    Churiwala, Sanjay; Gianfagna, Mike

    2011-01-01

    This book examines the impact of register transfer level (RTL) design choices that may result in issues of testability, data synchronization across clock domains, synthesizability, power consumption and routability, that appear later in the product lifecycle.

  3. A tool for automatic generation of RTL-level VHDL description of RNS FIR filters

    DEFF Research Database (Denmark)

    Re, Andrea Del; Nannarelli, Alberto; Re, Marco

    2004-01-01

    Although digital filters based on the Residue Number System (RNS) show high performance and low power dissipation, RNS filters are not widely used in DSP systems, because of the complexity of the algorithms involved. We present a tool to design RNS FIR filters which hides the RNS algorithms to th...

  4. RTL2RTL Formal Equivalence: Boosting the Design Confidence

    Directory of Open Access Journals (Sweden)

    M V Achutha Kiran Kumar

    2014-07-01

    Full Text Available Increasing design complexity driven by feature and performance requirements and the Time to Market (TTM constraints force a faster design and validation closure. This in turn enforces novel ways of identifying and debugging behavioral inconsistencies early in the design cycle. Addition of incremental features and timing fixes may alter the legacy design behavior and would inadvertently result in undesirable bugs. The most common method of verifying the correctness of the changed design is to run a dynamic regression test suite before and after the intended changes and compare the results, a method which is not exhaustive. Modern Formal Verification (FV techniques involving new methods of proving Sequential Hardware Equivalence enabled a new set of solutions for the given problem, with complete coverage guarantee. Formal Equivalence can be applied for proving functional integrity after design changes resulting from a wide variety of reasons, ranging from simple pipeline optimizations to complex logic redistributions. We present here our experience of successfully applying the RTL to RTL (RTL2RTL Formal Verification across a wide spectrum of problems on a Graphics design. The RTL2RTL FV enabled checking the design sanity in a very short time, thus enabling faster and safer design churn. The techniques presented in this paper are applicable to any complex hardware design.

  5. North RTL ''grid scan'' studies

    International Nuclear Information System (INIS)

    Emma, P.

    1990-01-01

    This study was made in response to screen measurements which indicated an emittance growth of nearly a factor of two within the North RTL or linac girder-1. Betatron oscillations are induced at the beginning of the North RTL to search for gross geometric aberrations arising within the RTL or sector-2 of the linac. The oscillations are induced horizontally and vertically with two X or two Y dipole correctors stepped in a nested loop fashion. In both cases the full set of RTL and first girder sector-2 linac beam position monitors (BPMs) are sampled in X and Y for each corrector setting. Horizontal (or vertical) data from pairs of BPMs are then transformed to phase space coordinates by the linear transformation constructed assuming the transport optics between the BPMs is known. A second transformation is then made to normalized phase space coordinates by using Twiss parameters consistent with the assumed transport optics. By careful choice of initial Twiss parameters the initial grid can be made square for convenience in graphical interpretation. A linear ''grid'' is then fitted to the transformed data points for each pair of BPMs. The area of each grid is calculated and linearity qualitatively evaluated. Furthermore, although not the focus of this study, the beta match at each BPM can be quantified. 6 figs

  6. Recycling issues facing target and RTL materials of inertial fusion designs

    International Nuclear Information System (INIS)

    El-Guebaly, L.; Wilson, P.; Sawan, M.; Henderson, D.; Varuttamaseni, A.

    2005-01-01

    Designers of heavy ion (HI) and Z-pinch inertial fusion power plants have explored the potential of recycling the target and recyclable transmission line (RTL) materials as an alternate option to disposal in a geological repository. This work represents the first time a comprehensive recycling assessment was performed on both machines with an exact pulse history. Our results offer two divergent conclusions on the recycling issue. For the HI concept, target recycling is not a 'must' requirement and the preferred option is the one-shot use scenario as target materials represent a small waste stream, less than 1% of the total nuclear island waste. We recommend using low-cost hohlraum materials once-through and then disposing of them instead of recycling expensive materials such as Au and Gd. On the contrary, RTL recycling is a 'must' requirement for the Z-pinch concept in order to minimize the RTL inventory and enhance the economics. The RTLs meet the low level waste and recycling dose requirements with a wide margin when recycled for the entire plant life even without a cooling period. While recycling offers advantages to the Z-pinch system, it adds complexity and cost to the HI designs

  7. Aberrant epigenetic reprogramming of imprinted microRNA-127 and Rtl1 in cloned mouse embryos

    International Nuclear Information System (INIS)

    Cui Xiangshun; Zhang Dingxiao; Ko, Yoeung-Gyu; Kim, Nam-Hyung

    2009-01-01

    The microRNA (miRNA) genes mir-127 and mir-136 are located near two CpG islands in the imprinted mouse retrotransposon-like gene Rtl1, a key gene involved in placenta formation. These miRNAs appear to be involved in regulating the imprinting of Rtl1. To obtain insights into the epigenetic reprogramming of cloned embryos, we compared the expression levels of mir-127 and mir-136 in fertilized mouse embryos, parthenotes, androgenotes and cloned embryos developing in vitro. We also examined the DNA methylation status of the promoter regions of Rtl1 and mir-127 in these embryos. Our data showed that mir-127 and mir-136 were highly expressed in parthenotes, but rarely expressed in androgenotes. Interestingly, the expression levels of mir-127 and mir-136 in parthenotes were almost twice that seen in the fertilized embryos, but were much lower in the cloned embryos. The Rtl1 promoter region was hyper-methylated in blastocyst stage parthenotes (75.0%), moderately methylated (32.4%) in the fertilized embryos and methylated to a much lower extent (∼10%) in the cloned embryos. Conversely, the promoter region of mir-127 was hypo-methylated in parthenogenetically activated embryos (0.4%), moderately methylated (30.0%) in fertilized embryos and heavily methylated in cloned blastocysts (63-70%). These data support a role for mir-127 and mir-136 in the epigenetic reprogramming of the Rtl1 imprinting process. Analysis of the aberrant epigenetic reprogramming of mir-127 and Rtl1 in cloned embryos may help to explain the nuclear reprogramming procedures that occur in donor cells following somatic cell nuclear transfer (SCNT).

  8. PLD based design with VHDL RTL design, synthesis and implementation

    CERN Document Server

    Taraate, Vaibbhav

    2017-01-01

    This book covers basic fundamentals of logic design and advanced RTL design concepts using VHDL. The book is organized to describe both simple and complex RTL design scenarios using VHDL. It gives practical information on the issues in ASIC prototyping using FPGAs, design challenges and how to overcome practical issues and concerns. It describes how to write an efficient RTL code using VHDL and how to improve the design performance. The design guidelines by using VHDL are also explained with the practical examples in this book. The book also covers the ALTERA and XILINX FPGA architecture and the design flow for the PLDs. The contents of this book will be useful to students, researchers, and professionals working in hardware design and optimization. The book can also be used as a text for graduate and professional development courses.

  9. Recyclable transmission line (RTL) and linear transformer driver (LTD) development for Z-pinch inertial fusion energy (Z-IFE) and high yield

    International Nuclear Information System (INIS)

    Sharpe, Robin Arthur; Kingsep, Alexander S.; Smith, David Lewis; Olson, Craig Lee; Ottinger, Paul F.; Schumer, Joseph Wade; Welch, Dale Robert; Kim, Alexander; Kulcinski, Gerald L.; Kammer, Daniel C.; Rose, David Vincent; Nedoseev, Sergei L.; Pointon, Timothy David; Smirnov, Valentin P.; Turgeon, Matthew C.; Kalinin, Yuri G.; Bruner, Nichelle

    2007-01-01

    Z-Pinch Inertial Fusion Energy (Z-IFE) complements and extends the single-shot z-pinch fusion program on Z to a repetitive, high-yield, power plant scenario that can be used for the production of electricity, transmutation of nuclear waste, and hydrogen production, all with no CO 2 production and no long-lived radioactive nuclear waste. The Z-IFE concept uses a Linear Transformer Driver (LTD) accelerator, and a Recyclable Transmission Line (RTL) to connect the LTD driver to a high-yield fusion target inside a thick-liquid-wall power plant chamber. Results of RTL and LTD research are reported here, that include: (1) The key physics issues for RTLs involve the power flow at the high linear current densities that occur near the target (up to 5 MA/cm). These issues include surface heating, melting, ablation, plasma formation, electron flow, magnetic insulation, conductivity changes, magnetic field diffusion changes, possible ion flow, and RTL mass motion. These issues are studied theoretically, computationally (with the ALEGRA and LSP codes), and will work at 5 MA/cm or higher, with anode-cathode gaps as small as 2 mm. (2) An RTL misalignment sensitivity study has been performed using a 3D circuit model. Results show very small load current variations for significant RTL misalignments. (3) The key structural issues for RTLs involve optimizing the RTL strength (varying shape, ribs, etc.) while minimizing the RTL mass. Optimization studies show RTL mass reductions by factors of three or more. (4) Fabrication and pressure testing of Z-PoP (Proof-of-Principle) size RTLs are successfully reported here. (5) Modeling of the effect of initial RTL imperfections on the buckling pressure has been performed. Results show that the curved RTL offers a much greater buckling pressure as well as less sensitivity to imperfections than three other RTL designs. (6) Repetitive operation of a 0.5 MA, 100 kV, 100 ns, LTD cavity with gas purging between shots and automated operation is

  10. Recyclable transmission line (RTL) and linear transformer driver (LTD) development for Z-pinch inertial fusion energy (Z-IFE) and high yield.

    Energy Technology Data Exchange (ETDEWEB)

    Sharpe, Robin Arthur; Kingsep, Alexander S. (Kurchatov Institute, Moscow, Russia); Smith, David Lewis; Olson, Craig Lee; Ottinger, Paul F. (Naval Research Laboratory, Washington, DC); Schumer, Joseph Wade (Naval Research Laboratory, Washington, DC); Welch, Dale Robert (Voss Scientific, Albuquerque, NM); Kim, Alexander (High Currents Institute, Tomsk, Russia); Kulcinski, Gerald L. (University of Wisconsin, Madison, WI); Kammer, Daniel C. (University of Wisconsin, Madison, WI); Rose, David Vincent (Voss Scientific, Albuquerque, NM); Nedoseev, Sergei L. (Kurchatov Institute, Moscow, Russia); Pointon, Timothy David; Smirnov, Valentin P. (Kurchatov Institute, Moscow, Russia); Turgeon, Matthew C.; Kalinin, Yuri G. (Kurchatov Institute, Moscow, Russia); Bruner, Nichelle " Nicki" (Voss Scientific, Albuquerque, NM); Barkey, Mark E. (University of Alabama, Tuscaloosa, AL); Guthrie, Michael (University of Wisconsin, Madison, WI); Thoma, Carsten (Voss Scientific, Albuquerque, NM); Genoni, Tom C. (Voss Scientific, Albuquerque, NM); Langston, William L.; Fowler, William E.; Mazarakis, Michael Gerrassimos

    2007-01-01

    Z-Pinch Inertial Fusion Energy (Z-IFE) complements and extends the single-shot z-pinch fusion program on Z to a repetitive, high-yield, power plant scenario that can be used for the production of electricity, transmutation of nuclear waste, and hydrogen production, all with no CO{sub 2} production and no long-lived radioactive nuclear waste. The Z-IFE concept uses a Linear Transformer Driver (LTD) accelerator, and a Recyclable Transmission Line (RTL) to connect the LTD driver to a high-yield fusion target inside a thick-liquid-wall power plant chamber. Results of RTL and LTD research are reported here, that include: (1) The key physics issues for RTLs involve the power flow at the high linear current densities that occur near the target (up to 5 MA/cm). These issues include surface heating, melting, ablation, plasma formation, electron flow, magnetic insulation, conductivity changes, magnetic field diffusion changes, possible ion flow, and RTL mass motion. These issues are studied theoretically, computationally (with the ALEGRA and LSP codes), and will work at 5 MA/cm or higher, with anode-cathode gaps as small as 2 mm. (2) An RTL misalignment sensitivity study has been performed using a 3D circuit model. Results show very small load current variations for significant RTL misalignments. (3) The key structural issues for RTLs involve optimizing the RTL strength (varying shape, ribs, etc.) while minimizing the RTL mass. Optimization studies show RTL mass reductions by factors of three or more. (4) Fabrication and pressure testing of Z-PoP (Proof-of-Principle) size RTLs are successfully reported here. (5) Modeling of the effect of initial RTL imperfections on the buckling pressure has been performed. Results show that the curved RTL offers a much greater buckling pressure as well as less sensitivity to imperfections than three other RTL designs. (6) Repetitive operation of a 0.5 MA, 100 kV, 100 ns, LTD cavity with gas purging between shots and automated operation is

  11. Middle Pleistocene volcanic activity dated by red thermoluminescence (RTL) - a case study from Lanzarote (Canary Islands)

    Science.gov (United States)

    von Suchodoletz, H.; Blanchard, H.; Rittner, S.; Radtke, U.; Fuchs, M.; Dietze, M.; Zöller, L.

    2009-04-01

    On Lanzarote (Canary Islands) soils were baked by Quaternary lava flows. This offers the possibility to date phases of eruptive activity by red thermoluminescence (RTL). We dated soil material baked by two different lava flows originating from the "Las Calderetas de Guatiza" volcanic chain in the northeast of the island by RTL. Furthermore, three samples of Helicidae-mollusk shells overlying one of the lava flows (site Mála) were dated using electron spin resonance (ESR). RTL datings were carried out using quartz grains 63-200 µm from baked material that were originally brought by eolian transport from the nearby Saharan desert. It appears that in spite of a baking temperature Lanzarote by RTL thus offers the possibility to further investigate the yet fragmentary Middle and Late Quaternary eruptive history of these islands.

  12. RTL modeling with SystemVerilog for simulation and synthesis using SystemVerilog for ASIC and FPGA design

    CERN Document Server

    Sutherland, Stuart

    2017-01-01

    This book is both a tutorial and a reference for engineers who use the SystemVerilog Hardware Description Language (HDL) to design ASICs and FPGAs. The book shows how to write SystemVerilog models at the Register Transfer Level (RTL) that simulate and synthesize correctly, with a focus on proper coding styles and best practices. SystemVerilog is the latest generation of the original Verilog language, and adds many important capabilities to efficiently and more accurately model increasingly complex designs. This book reflects the SystemVerilog-2012/2017 standards. This book is for engineers who already know, or who are learning, digital design engineering. The book does not present digital design theory; it shows how to apply that theory to write RTL models that simulate and synthesize correctly. The creator of the original Verilog Language, Phil Moorby says about this book (an excerpt from the book's Foreword): “Many published textbooks on the design side of SystemVerilog assume that the reader is familiar ...

  13. Women in Television News: Analysis of Primetime News on HTV, RTL and Nova TV

    Directory of Open Access Journals (Sweden)

    Svjetlana Knežević

    2011-12-01

    Full Text Available This article assesses the particularly low level of women represented on national primetime television newscasts in Croatia. In doing so, it presents the results of a content analysis covering a random,stratified sample of HTV, Nova TV, and RTL primetime news broadcasts over the years 2009 and 2010. According to these results, women are significantly underrepresented as main characters, experts, or even persons relevant to news stories concerning issues or problems. In particular, the results are most apparent on the primetime newscast Dnevnik, broadcasted daily on Croatia’s main public television station. Ideally, this news broadcast should rank among the best in terms of gender equality, given the principles of equality stipulated throughout Croatian law (and especially where it concerns programming legislation. Concerning the analyzed content, when women serve as the main characters in a news story, their emotional response to an issue appears to be almost obligatory. Further, women are often portrayed as victims, or as a figure to galvanize a rather black and white response, i.e. they are to be praised or blamed. Adding to this gender discrepancy, statistics show that more women than men have earned BA and MA degrees, which not only highlights the unbalanced representation of women on television news, but also distorts the actual level of female participation in society, particularly where it regards sociopolitical fields.

  14. Nuclear power: levels of safety

    International Nuclear Information System (INIS)

    Lidsky, L.M.

    1988-01-01

    The rise and fall of the nuclear power industry in the United States is a well-documented story with enough socio-technological conflict to fill dozens of scholarly, and not so scholarly, books. Whatever the reasons for the situation we are now in, and no matter how we apportion the blame, the ultimate choice of whether to use nuclear power in this country is made by the utilities and by the public. Their choices are, finally, based on some form of risk-benefit analysis. Such analysis is done in well-documented and apparently logical form by the utilities and in a rather more inchoate but not necessarily less accurate form by the public. Nuclear power has failed in the United States because both the real and perceived risks outweigh the potential benefits. The national decision not to rely upon nuclear power in its present form is not an irrational one. A wide ranging public balancing of risk and benefit requires a classification of risk which is clear and believable for the public to be able to assess the risks associated with given technological structures. The qualitative four-level safety ladder provides such a framework. Nuclear reactors have been designed which fit clearly and demonstrably into each of the possible qualitative safety levels. Surprisingly, it appears that safer may also mean cheaper. The intellectual and technical prerequisites are in hand for an important national decision. Deployment of a qualitatively different second generation of nuclear reactors can have important benefits for the United States. Surprisingly, it may well be the nuclear establishment itself, with enormous investments of money and pride in the existing nuclear systems, that rejects second generation reactors. It may be that we will not have a second generation of reactors until the first generation of nuclear engineers and nuclear power advocates has retired

  15. RTL validation methodology on high complexity wireless microcontroller using OVM technique for fast time to market

    Directory of Open Access Journals (Sweden)

    Muhammad Nurul Zhafirah

    2017-01-01

    Full Text Available Increased demand in internet of thing (IOT application based has inadvertently forced the move towards higher complexity of integrated circuit supporting SoC. Such spontaneous increased in complexity poses unequivocal complicated validation strategies. Hence, the complexity allows researchers to come out with various exceptional methodologies in order to overcome this problem. This in essence brings about the discovery of dynamic verification, formal verification and hybrid techniques. In reserve, it is very important to discover bugs at infancy of verification process in (SoC in order to reduce time consuming and fast time to market for the system. Ergo, in this paper we are focusing on the methodology of verification that can be done at Register Transfer Level of SoC based on the AMBA bus design. On top of that, the discovery of others verification method called Open Verification Methodology (OVM brings out an easier way in RTL validation methodology neither as the replacement for the traditional method yet as an effort for fast time to market for the system. Thus, the method called OVM is proposed in this paper as the verification method for larger design to avert the disclosure of the bottleneck in validation platform.

  16. RTL validation methodology on high complexity wireless microcontroller using OVM technique for fast time to market

    Science.gov (United States)

    Zhafirah Muhammad, Nurul; Harun, A.; Hambali, N. A. M. A.; Murad, S. A. Z.; Mohyar, S. N.; Isa, M. N.; Jambek, AB

    2017-11-01

    Increased demand in internet of thing (IOT) application based has inadvertently forced the move towards higher complexity of integrated circuit supporting SoC. Such spontaneous increased in complexity poses unequivocal complicated validation strategies. Hence, the complexity allows researchers to come out with various exceptional methodologies in order to overcome this problem. This in essence brings about the discovery of dynamic verification, formal verification and hybrid techniques. In reserve, it is very important to discover bugs at infancy of verification process in (SoC) in order to reduce time consuming and fast time to market for the system. Ergo, in this paper we are focusing on the methodology of verification that can be done at Register Transfer Level of SoC based on the AMBA bus design. On top of that, the discovery of others verification method called Open Verification Methodology (OVM) brings out an easier way in RTL validation methodology neither as the replacement for the traditional method yet as an effort for fast time to market for the system. Thus, the method called OVM is proposed in this paper as the verification method for larger design to avert the disclosure of the bottleneck in validation platform.

  17. In vitro toxicity of selected pesticides on RTG-2 and RTL-W1 fish cell lines

    International Nuclear Information System (INIS)

    Babin, M.M.; Tarazona, J.V.

    2005-01-01

    The rainbow trout fish cell lines RTG-2 and RTL-W1 were used to determine the cytotoxic effects of the pesticides bifenthrin, cypermethrin, cyhalothrin, λ-cyhalothrin, quinalphos and chlorpyrifos. Cytotoxicity was measured by EROD and β-Gal enzymatic activities, the neutral red (NR) uptake assay, and the FRAME KB protein (KBP) assay. The β-Gal activity was unaffected by the pesticide exposure. The EROD activity was induced by cyhalothrin and λ-cyhalothrin (RTG-2 and RTL-W1) and by bifenthrin (RTL-W1). Dose dependent inhibition responses were observed for EROD activity in cells exposed to quinalphos (RTL-W1) and chlorpyrifos (RTG-2 and RTL-W1). RTL-W1 offered a better response for EROD induction. The EC50 values on EROD endpoint were more sensitive than NR and KBP. The acute fish toxicity of chlorpyrifos and quinalphos depends highly on the species; the species sensitivity distributions cover several orders of magnitude and the values obtained for EROS were within the lowest part of the reported ranges. - In vitro cell cultures can provide sensitive indicators for pesticide effects on biota

  18. In vitro toxicity of selected pesticides on RTG-2 and RTL-W1 fish cell lines

    Energy Technology Data Exchange (ETDEWEB)

    Babin, M.M. [Laboratory for Ecotoxicology, Department of the Environment, INIA, Crta. de La Coruna Km 7, 28040 Madrid (Spain)]. E-mail: babin@inia.es; Tarazona, J.V. [Laboratory for Ecotoxicology, Department of the Environment, INIA, Crta. de La Coruna Km 7, 28040 Madrid (Spain)

    2005-05-01

    The rainbow trout fish cell lines RTG-2 and RTL-W1 were used to determine the cytotoxic effects of the pesticides bifenthrin, cypermethrin, cyhalothrin, {lambda}-cyhalothrin, quinalphos and chlorpyrifos. Cytotoxicity was measured by EROD and {beta}-Gal enzymatic activities, the neutral red (NR) uptake assay, and the FRAME KB protein (KBP) assay. The {beta}-Gal activity was unaffected by the pesticide exposure. The EROD activity was induced by cyhalothrin and {lambda}-cyhalothrin (RTG-2 and RTL-W1) and by bifenthrin (RTL-W1). Dose dependent inhibition responses were observed for EROD activity in cells exposed to quinalphos (RTL-W1) and chlorpyrifos (RTG-2 and RTL-W1). RTL-W1 offered a better response for EROD induction. The EC50 values on EROD endpoint were more sensitive than NR and KBP. The acute fish toxicity of chlorpyrifos and quinalphos depends highly on the species; the species sensitivity distributions cover several orders of magnitude and the values obtained for EROS were within the lowest part of the reported ranges. - In vitro cell cultures can provide sensitive indicators for pesticide effects on biota.

  19. ClRTL1 Encodes a Chinese Fir RNase III–Like Protein Involved in Regulating Shoot Branching

    Directory of Open Access Journals (Sweden)

    Xia Li

    2015-10-01

    Full Text Available Identification of genes controlling shoot branching is crucial for improving plant architecture and increasing crop yield or biomass. A branching mutant of Chinese fir named “Dugansha” (Cunninghamia lanceolata var. dugan. has been isolated in our laboratory. We chose the cDNA-AFLP technique and an effective strategy to screen genes that potentially regulate shoot branching in Chinese fir using this mutant. An RNase III-like1 cDNA fragment named ClRTL1 was identified as a potential positive regulator. To investigate the function of ClRTL1 in regulating shoot branching, we cloned the full-length cDNA sequence from C. lanceolata (Lamb. Hook, deduced its secondary structure and function, and overexpressed the coding sequence in Arabidopsis. The ClRTL1 cDNA is 1045 bp and comprises an open reading frame of 705 bp. It encodes a protein of 235 amino acids. The deduced secondary structure of the ClRTL1 indicates that it is a mini-RNase III-like protein. The expression analysis and phenotypes of 35S: ClRTL1 in A. thaliana implies that ClRTL1 plays a role in promoting shoot branching in Chinese fir.

  20. Influence of the hold period on the fuel rod behaviour during a power ramp

    International Nuclear Information System (INIS)

    Bourreau, S.; Lansiart, S.; Couffin, P.; Verdeau, C.; Decroix, G.M.; Grandjean, M.-C.; Hugot, H.; Mermaz, F.; Van Schel, E.

    2000-01-01

    This paper presents three examples of power ramp tests performed in the OSIRIS experimental reactor, located at Saclay (France). The rods tested during these experiments stem from the same segmented 'mother' rod, pre-irradiated for two cycles in a French PWR. They underwent very similar power transient conditions, except for the hold time at Ramp Terminal Level (RTL) - respectively 41.5 kW/m (J12/2), 40.7 kW/m (J12/4) and 39.5 kW/m (J12/5) for RTL, but zero (J12/2), 16 minutes (J12/4) and 12 hours (J12/5) for the hold time at RTL. No failure was detected for any of the three experiments despite the relatively high mechanical stress applied to the cladding in the case of J12/2. Moreover, although no hold time was maintained at RTL, a permanent deformation clearly appeared on the clad during the power transient. An analysis of the cladding deformation has also been undertaken concerning the J12/2, J12/4 and J12/5 experiments. This study was realized by carrying out post-calculations of the three experiments with a 2D fuel modelling code using the finite element method. The computations satisfactorily reproduce the influence of hold time on the cladding deformation during the power transients, especially for the J12/2 and J12/4 experiments with hold times enclosing the failure times experimentally observed for power ramp tests. For the hold time of 12 hours, the micrographic observations of the fuel, compared to the case of the 16 minutes hold time, support the hypothesis of weak but noticeable gaseous swelling. (author)

  1. LPGC, Levelized Steam Electric Power Generator Cost

    International Nuclear Information System (INIS)

    Coen, J.J.; Delene, J.G.

    1994-01-01

    1 - Description of program or function: LPGC is a set of nine microcomputer programs for estimating power generation costs for large steam-electric power plants. These programs permit rapid evaluation using various sets of economic and technical ground rules. The levelized power generation costs calculated may be used to compare the relative economics of nuclear and coal-fired plants based on life-cycle costs. Cost calculations include capital investment cost, operation and maintenance cost, fuel cycle cost, decommissioning cost, and total levelized power generation cost. These programs can be used for quick analyses of power generation costs using alternative economic parameters, such as interest rate, escalation rate, inflation rate, plant lead times, capacity factor, fuel prices, etc. The two major types of electric generating plants considered are pressurized-water reactor (PWR) and pulverized coal-fired plants. Data are also provided for the Large Scale Prototype Breeder (LSPB) type liquid metal reactor. Costs for plant having either one or two units may be obtained. 2 - Method of solution: LPGC consists of nine individual menu-driven programs controlled by a driver program, MAINPWR. The individual programs are PLANTCAP, for calculating capital investment costs; NUCLOM, for determining operation and maintenance (O and M) costs for nuclear plants; COALOM, for computing O and M costs for coal-fired plants; NFUEL, for calculating levelized fuel costs for nuclear plants; COALCOST, for determining levelized fuel costs for coal-fired plants; FCRATE, for computing the fixed charge rate on the capital investment; LEVEL, for calculating levelized power generation costs; CAPITAL, for determining capitalized cost from overnight cost; and MASSGEN, for generating, deleting, or changing fuel cycle mass balance data for use with NFUEL. LPGC has three modes of operation. In the first, each individual code can be executed independently to determine one aspect of the total

  2. Architectural-level power estimation and experimentation

    Science.gov (United States)

    Ye, Wu

    With the emergence of a plethora of embedded and portable applications and ever increasing integration levels, power dissipation of integrated circuits has moved to the forefront as a design constraint. Recent years have also seen a significant trend towards designs starting at the architectural (or RT) level. Those demand accurate yet fast RT level power estimation methodologies and tools. This thesis addresses issues and experiments associate with architectural level power estimation. An execution driven, cycle-accurate RT level power simulator, SimplePower, was developed using transition-sensitive energy models. It is based on the architecture of a five-stage pipelined RISC datapath for both 0.35mum and 0.8mum technology and can execute the integer subset of the instruction set of SimpleScalar . SimplePower measures the energy consumed in the datapath, memory and on-chip buses. During the development of SimplePower , a partitioning power modeling technique was proposed to model the energy consumed in complex functional units. The accuracy of this technique was validated with HSPICE simulation results for a register file and a shifter. A novel, selectively gated pipeline register optimization technique was proposed to reduce the datapath energy consumption. It uses the decoded control signals to selectively gate the data fields of the pipeline registers. Simulation results show that this technique can reduce the datapath energy consumption by 18--36% for a set of benchmarks. A low-level back-end compiler optimization, register relabeling, was applied to reduce the on-chip instruction cache data bus switch activities. Its impact was evaluated by SimplePower. Results show that it can reduce the energy consumed in the instruction data buses by 3.55--16.90%. A quantitative evaluation was conducted for the impact of six state-of-art high-level compilation techniques on both datapath and memory energy consumption. The experimental results provide a valuable insight for

  3. Microprocessor-based accelerating power level detector

    Energy Technology Data Exchange (ETDEWEB)

    Nagpal, M.; Zarecki, W.; Albrecht, J.C.

    1994-01-01

    An accelerating power level detector was built using state-of-the-art microprocessor technology at Powertech Labs Inc. The detector will monitor the real power flowing in two 300 kV transmission lines out of Kemano Hydroelectric Generating Station and will detect any sudden loss of load due to a fault on either line under certain pre-selected power flow conditions. This paper discusses the criteria of operation for the detector and its implementation details, including digital processing, hardware, and software.

  4. The sensitivity of RTL, RPL and photographic detectors to 14.7MeV neutrons

    International Nuclear Information System (INIS)

    Spurny, Frantisek; Medioni, Roger; Portal, Guy.

    1975-08-01

    The sensitivity of various types of γ detectors to neutrons should be known for a better dosimetry of electromagnetic radiations in neutron fields. The sensitivity of various types of detectors to 14.7MeV neutrons was studied using RTL (LiF, 7 LiF, Ca SO 4 : Dy Al 2 O) RPL (C.E.C. glasses) and photographic detectors (Kodak-Pathe dosemeters). The methods used for the determination of the neutron and photon mixed field are described and the effect of containers and packing on the accuracy of results was investigated. For each detector studied the specific sensitivity to neutrons (sensitivity of the product alone) and the apparent sensitivity in usual operating conditions (action of surrounding materials) is given [fr

  5. Low Power Design with High-Level Power Estimation and Power-Aware Synthesis

    CERN Document Server

    Ahuja, Sumit; Shukla, Sandeep Kumar

    2012-01-01

    Low-power ASIC/FPGA based designs are important due to the need for extended battery life, reduced form factor, and lower packaging and cooling costs for electronic devices. These products require fast turnaround time because of the increasing demand for handheld electronic devices such as cell-phones, PDAs and high performance machines for data centers. To achieve short time to market, design flows must facilitate a much shortened time-to-product requirement. High-level modeling, architectural exploration and direct synthesis of design from high level description enable this design process. This book presents novel research techniques, algorithms,methodologies and experimental results for high level power estimation and power aware high-level synthesis. Readers will learn to apply such techniques to enable design flows resulting in shorter time to market and successful low power ASIC/FPGA design. Integrates power estimation and reduction for high level synthesis, with low-power, high-level design; Shows spec...

  6. Power monitors: A framework for system-level power estimation using heterogeneous power models

    NARCIS (Netherlands)

    Bansal, N.; Lahiri, K.; Raghunathan, A.; Chakradhar, S.T.

    2005-01-01

    Paper analysis early in the design cycle is critical for the design of low-power systems. With the move to system-level specifications and design methodologies, there has been significant research interest in system-level power estimation. However, as demonstrated in this paper, the addition of

  7. Comparative genotoxicity testing of Rhine river sediment extracts using the comet assay with permanent fish cell lines (RTG-2 and RTL-W1) and the Ames test

    Energy Technology Data Exchange (ETDEWEB)

    Kosmehl, T.; Braunbeck, T.; Hollert, H. [Dept. of Zoology, Aquatic Ecology and Toxicology Section, Univ. of Heidelberg (Germany); Krebs, F.; Manz, W. [German Federal Inst. of Hydrology, Koblenz (Germany); Erdinger, L. [Dept. for Hygiene and Medical Microbiology, Inst. for Hygiene, Univ. of Heidelberg (Germany)

    2004-07-01

    less biotransformation-competent RTG-2 cells. Exogenous bioactivation by addition of {beta}-naphthoflavone / phenobarbital-induced S9 from rat liver resulted in both reduction or increase of genotoxicity in samples from different sites, however, without consistent reaction patterns. In general, the responses of RTL-W1 cells indicated higher biotransformation capacity than in RTG-2 cells without S9 complementation. In Ames tests using TA98 with S9, 16 out of 18 extracts induced significant mutagenicity with induction factors up to 4. Compared to TA98, the strain TA100 proved less sensitive, with maximum induction factors of 1.3, indicating the potential presence of substances inducing frameshift mutations, which can only be detected in the strain TA98. Chemical analyses revealed particularly high levels of hexachlorbenzene (up to 860 {mu}g/kg) and priority PAHs (up to 4.8 mg/kg); so far, however, no correlation could be found between compounds analyzed and the corresponding biotests. (orig.)

  8. Nuclear power and low level radiation hazards

    International Nuclear Information System (INIS)

    Myers, D.K.; Newcombe, H.B.

    1979-03-01

    Even in the future, nuclear power is expected to contribute less than 1/10th of the present total population exposure to man-made radiation. By the best estimates available, the current health risks of nuclear power generation appear to be much less than those associated with the major alternative sources of energy, with the exception of natural gas which is about equally safe. Uncertainties concerning the radiation risks from nuclear power, from medical x-rays and from the effects of reduced ventillation to conserve heat appear to be less than those associated with estimates of risks from the use of coal and various other sources of energy. This is in part because of the large amount of effort devoted to studies of radiation effects. The benefits in terms of current life expectancy associated with any of the conventional or unconventional methods of power production appear to greatly outweigh the associated current health hazards. (author)

  9. Varying ultrasound power level to distinguish surgical instruments and tissue.

    Science.gov (United States)

    Ren, Hongliang; Anuraj, Banani; Dupont, Pierre E

    2018-03-01

    We investigate a new framework of surgical instrument detection based on power-varying ultrasound images with simple and efficient pixel-wise intensity processing. Without using complicated feature extraction methods, we identified the instrument with an estimated optimal power level and by comparing pixel values of varying transducer power level images. The proposed framework exploits the physics of ultrasound imaging system by varying the transducer power level to effectively distinguish metallic surgical instruments from tissue. This power-varying image-guidance is motivated from our observations that ultrasound imaging at different power levels exhibit different contrast enhancement capabilities between tissue and instruments in ultrasound-guided robotic beating-heart surgery. Using lower transducer power levels (ranging from 40 to 75% of the rated lowest ultrasound power levels of the two tested ultrasound scanners) can effectively suppress the strong imaging artifacts from metallic instruments and thus, can be utilized together with the images from normal transducer power levels to enhance the separability between instrument and tissue, improving intraoperative instrument tracking accuracy from the acquired noisy ultrasound volumetric images. We performed experiments in phantoms and ex vivo hearts in water tank environments. The proposed multi-level power-varying ultrasound imaging approach can identify robotic instruments of high acoustic impedance from low-signal-to-noise-ratio ultrasound images by power adjustments.

  10. Towards upper power levels: thermonuclear fusion

    International Nuclear Information System (INIS)

    Vedel, Jean

    1983-01-01

    This paper is a brief introduction to the use of power lasers to achieve controlled thermonuclear fusion. After shortly describing thermonuclear fusion and the conditions of temperature, density and duration required it is showed how the laser enables such conditions to be created. The neodymium-doped glass laser NOVA that is being installed at the Livermore laboratory in the USA is described; at the time of its completion in 1984, this laser will be the most powerful in the world. In comparison, the OCTAL laser in operation at the Limeil establishment ''Centre d'Etudes'' of ''Commissariat Francais a l'Energie Atomique'' (the French atomic energy authority) is more modest; it is presented here [fr

  11. The Power of Cross-Level Partnerships.

    Science.gov (United States)

    Youngerman, Stephanie

    1998-01-01

    Much credit for the tangible feeling of caring at an Idaho elementary school is due to partnerships that faculty, families, and students have forged across grade levels. These cross-grade buddy systems have put the brakes on bullies, fostered student friendships, and resolved personality conflicts among staff members. (MLH)

  12. Reactive Power Impact on Lifetime Prediction of Two-level Wind Power Converter

    DEFF Research Database (Denmark)

    Zhou, Dao; Blaabjerg, Frede; Lau, M.

    2013-01-01

    The influence of reactive power injection on the dominating two-level wind power converter is investigated and compared in terms of power loss and thermal behavior. Then the lifetime of both the partial-scale and full-scale power converter is estimated based on the widely used Coffin-Manson model...

  13. Analysis of superconducting microstrip resonator at various microwave power levels

    International Nuclear Information System (INIS)

    Srivastava, G.P.; Jacob, M.V.; Jayakumar, M.; Bhatnagar, P.K.; Kataria, N.D.

    1997-01-01

    The real and imaginary parts of the surface impedance of YBCO superconductors have been studied at different microwave power levels. Using the relations for the critical current density and the grain boundary resistance, a relation for calculating the power dependence of the surface resistance has been obtained. Also, a relation to find the resonant frequency of a superconducting microstrip resonator at various input power levels has been derived. Measurements have been carried out on various microstrip resonators to study the variation of surface resistance and resonant frequency at different rf power levels. The experimental results are in good agreement with theoretical results. copyright 1997 American Institute of Physics

  14. University students' understanding level about words related to nuclear power

    International Nuclear Information System (INIS)

    Oiso, Shinichi; Watabe, Motoki

    2012-01-01

    The authors conducted a survey of university students' understanding level about words related to nuclear power before and after Fukushima Daiichi Power Plant accident, and analyzed the difference between before and after the accident. The results show that university students' understanding level improved after the accident, especially in the case of reported words by mass media. Understanding level of some nuclear power security words which were not reported so much by mass media also improved. That may be caused by rising of people's concern about nuclear power generation after the accident, and there is a possibility that the accident motivated people to access such words via internet, journals, etc. (author)

  15. Challenges with Tertiary-Level Mechatronic Fluid Power

    DEFF Research Database (Denmark)

    Dransfield, Peter; Conrad, Finn

    1996-01-01

    As authors we take the view that mechatronics, as it relates to fluid power, has three levels which we designate as primary, secondary and tertiary. A brief review of the current status of fluid power, hydraulic and pneumatic, and of electronic control of it is presented and discussed. The focus...... is then on tertiary-level mechatronic fluid power and the challenges to it being applied successfully....

  16. Kinetic inductance of HTS resonators at various microwave power levels

    International Nuclear Information System (INIS)

    Srivastava, G.P.; Jacob, Mohan V.

    1997-01-01

    Microwave superconducting devices show a drastic deterioration in its performance at high microwave power levels. The flux penetration through the weak links increases the quasiparticle concentration which results in the increase of penetration depth and hence the kinetic inductance. We have modeled an expression to find the kinetic inductance at various RF power levels. The results show that the change in kinetic inductance is proportional to be square of the applied field. This model can explain the reported experimental results at and below the intermediate power levels. (author)

  17. Simulation of decreasing reactor power level with BWR simulator

    International Nuclear Information System (INIS)

    Suwoto; Zuhair; Rivai, Abu Khalid

    2002-01-01

    Study on characteristic of BWR using Desktop PC Based Simulator Program was analysed. This simulator is more efficient and cheaper for analyzing of characteristic and dynamic respond than full scope simulator for decreasing power level of BW. Dynamic responses of BWR reactor was investigated during the power level reduction from 100% FP (Full Power) which is 3926 MWth to 0% FP with 25% steps and 1 % FP/sec rate. The overall results for core flow rate, reactor steam flow, feed-water flow and turbine-generator power show tendency proportional to reduction of reactor power. This results show that reactor power control in BWR could be done by control of re-circulation flow that alter the density of water used as coolant and moderator. Decreasing the re-circulation flow rate will decrease void density which has negative reactivity and also affect the position of control rods

  18. Experimental Study of a Multi Level Overtopping Wave Power Device

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter; Hald, Tue; Frigaard, Peter Bak

    2002-01-01

    Results of experimental investigations of a floating wave energy device called Power Pyramid is presented. The Power Pyramid utilizes reservoirs in multiple levels when capturing wave overtopping and converting it into electrical energy. The effect of capturing the overtopping in multiple levels,......, using 5 levels introduces practical problems, and is most probably not economically feasible. It is concluded that it is reasonable to use 2 levels (maybe 3), which can increase the efficiency by 25-40 % compared to using a single level.......Results of experimental investigations of a floating wave energy device called Power Pyramid is presented. The Power Pyramid utilizes reservoirs in multiple levels when capturing wave overtopping and converting it into electrical energy. The effect of capturing the overtopping in multiple levels......, compared to only one level, has been evaluated experimentally. From the experimental results, and the performed optimizations based on these, it has been found that the efficiency of a wave power device of the overtopping type can be increased by as much as 76 % by using 5 levels instead of 1. However...

  19. Ultrasonic level and temperature sensor for power reactor applications

    International Nuclear Information System (INIS)

    Dress, W.B.; Miller, G.N.

    1983-01-01

    An ultrasonic waveguide employing torsional and extensional acoustic waves has been developed for use as a level and temperature sensor in pressurized and boiling water nuclear power reactors. Features of the device include continuous measurement of level, density, and temperature producing a real-time profile of these parameters along a chosen path through the reactor vessel

  20. User's manual for levelized power generation cost using a microcomputer

    International Nuclear Information System (INIS)

    Fuller, L.C.

    1984-08-01

    Microcomputer programs for the estimation of levelized electrical power generation costs are described. Procedures for light-water reactor plants and coal-fired plants include capital investment cost, operation and maintenance cost, fuel cycle cost, nuclear decommissioning cost, and levelized total generation cost. Programs are written in Pascal and are run on an Apple II Plus microcomputer

  1. POWER LEVEL EFFECT IN A PWR ROD EJECTION ACCIDENT

    International Nuclear Information System (INIS)

    Diamond, D.J.; Bromley, B.P.; Aronson, A.L.

    2002-01-01

    The purpose of this study is to determine the effect of the initial power level during a rod ejection accident (REA) on the ejected rod worth and the resulting energy deposition in the fuel. The model used is for the hot zero power (HZP) conditions at the end of a typical fuel cycle for the Three Mile Island Unit 1 pressurized water reactor. PARCS , a transient, three-dimensional, two-group neutron nodal diffusion code, coupled with its own thermal-hydraulics model, is used to perform both steady-state and transient simulations. The worth of an ejected control rod is affected by both power level, and the positions of control banks. As the power level is increased, the worth of a single central control rod tends to drop due to thermal-hydraulic feedback and control bank removal, both of which flatten the radial neutron flux and power distributions. Although the peak fuel pellet enthalpy rise during an REA will be greater for a given ejected rod worth at elevated initial power levels, it is more likely the HZP condition will cause a greater net energy deposition because an ejected rod will have the highest worth at HZP. Thus, the HZP condition can be considered the most conservative in a safety evaluation

  2. Helicobacter pyloriinfeksiyonlu genç hastalarda tedavi seçenekleri; Standard üçlü veya bismuth bazlı dörtlü tedavi

    OpenAIRE

    SAVAŞ, Nurten

    2015-01-01

    Giriş ve Amaç: Helicobacter pylori dünyada tüm yaş gruplarında en sık görülen gastrik patojen olup bu patojenin eradikasyon oranları gün geçtikçe azalmaktadır. Bu çalışmanın amacı dispepsisi olan Helicobacter pylori pozitif genç hastalarda standard üçlü ve bizmut bazlı dörtlü tadavilerin başarı oranlarını belirlemek ve tedaviye cevapsızlık durumunda levofloksasin bazlı üçlü ve yine bizmut bazlı dörtlü ikinci basamak tedavilerinin başarı oranlarını saptamaktır. Gereç ve Yöntem: Otuz be...

  3. Power Constrained High-Level Synthesis of Battery Powered Digital Systems

    DEFF Research Database (Denmark)

    Nielsen, Sune Fallgaard; Madsen, Jan

    2003-01-01

    We present a high-level synthesis algorithm solving the combined scheduling, allocation and binding problem minimizing area under both latency and maximum power per clock-cycle constraints. Our approach eliminates the large power spikes, resulting in an increased battery lifetime, a property...... of utmost importance for battery powered embedded systems. Our approach extends the partial-clique partitioning algorithm by introducing power awareness through a heuristic algorithm which bounds the design space to those of power feasible schedules. We have applied our algorithm on a set of dataflow graphs...

  4. Comparative Cytotoxicity Study of Silver Nanoparticles (AgNPs in a Variety of Rainbow Trout Cell Lines (RTL-W1, RTH-149, RTG-2 and Primary Hepatocytes

    Directory of Open Access Journals (Sweden)

    Mona Connolly

    2015-05-01

    Full Text Available Among all classes of nanomaterials, silver nanoparticles (AgNPs have potentially an important ecotoxicological impact, especially in freshwater environments. Fish are particularly susceptible to the toxic effects of silver ions and, with knowledge gaps regarding the contribution of dissolution and unique particle effects to AgNP toxicity, they represent a group of vulnerable organisms. Using cell lines (RTL-W1, RTH-149, RTG-2 and primary hepatocytes of rainbow trout (Oncorhynchus mykiss as in vitro test systems, we assessed the cytotoxicity of the representative AgNP, NM-300K, and AgNO3 as an Ag+ ion source. Lack of AgNP interference with the cytotoxicity assays (AlamarBlue, CFDA-AM, NRU assay and their simultaneous application point to the compatibility and usefulness of such a battery of assays. The RTH-149 and RTL-W1 liver cell lines exhibited similar sensitivity as primary hepatocytes towards AgNP toxicity. Leibovitz’s L-15 culture medium composition (high amino acid content had an important influence on the behaviour and toxicity of AgNPs towards the RTL-W1 cell line. The obtained results demonstrate that, with careful consideration, such an in vitro approach can provide valuable toxicological data to be used in an integrated testing strategy for NM-300K risk assessment.

  5. A New RTL Design Approach for a DCT/IDCT-Based Image Compression Architecture using the mCBE Algorithm

    Directory of Open Access Journals (Sweden)

    Rachmad Vidya Wicaksana Putra

    2012-09-01

    Full Text Available In the literature, several approaches of designing a DCT/IDCT-based image compression system have been proposed. In this paper, we present a new RTL design approach with as main focus developing a DCT/IDCT-based image compression architecture using a self-created algorithm. This algorithm can efficiently minimize the amount of shifter-adders to substitute multipliers. We call this new algorithm the multiplication from Common Binary Expression (mCBE Algorithm. Besides this algorithm, we propose alternative quantization numbers, which can be implemented simply as shifters in digital hardware. Mostly, these numbers can retain a good compressed-image quality compared to JPEG recommendations. These ideas lead to our design being small in circuit area, multiplierless, and low in complexity. The proposed 8-point 1D-DCT design has only six stages, while the 8-point 1D-IDCT design has only seven stages (one stage being defined as equal to the delay of one shifter or 2-input adder. By using the pipelining method, we can achieve a high-speed architecture with latency as a trade-off consideration. The design has been synthesized and can reach a speed of up to 1.41ns critical path delay (709.22MHz.

  6. Watt-level wireless power transmission to multiple compact receivers

    International Nuclear Information System (INIS)

    Garraud, A; Munzer, D J; Althar, M; Garraud, N; Arnold, D P

    2015-01-01

    This paper reports an electrodynamic wireless power transmission (EWPT) system using a low-frequency (300 Hz) magnetic field to transmit watt-scale power levels to multiple compact receivers. As compared to inductively or resonantly coupled coils, EWPT facilitates transmission to multiple non-interacting receivers with little restriction on their orientation. A single 3.0 cm 3 receiver achieves 1.25 W power transmission with 8% efficiency at a distance of 1 cm (350 mW/cm 3 power density) from the transmitter. The same prototype achieves 9 mW at a distance of 9 cm. Moreover, we demonstrate simultaneous recharge of two wearable devices, using two receivers located in arbitrary positions and orientations. (paper)

  7. Seismic fragility levels of nuclear power plant equipment

    International Nuclear Information System (INIS)

    Bandyopadhyay, K.K.; Hofmayer, C.H.

    1987-01-01

    Seismic fragility levels of safety-related electrical and mechanical equipment used in nuclear power plants are discussed. The fragility level is defined as the vibration level corresponding to initiation of equipment malfunctions. The test response spectrum is used as a measure of this vibration level. The fragility phenomenon of an equipment is represented by a number of response spectra corresponding to various failure modes. Analysis methods are described for determination of the fragility level by use of existing test data. Useful conversion factors are tabulated to transform test response spectra from one damping value to another. Results are presented for switch-gears and motor control centers. The capacity levels of these equipment assemblies are observed to be limited by malfunctioning of contactors, motor starters, relays and/or switches. The applicability of the fragility levels, determined in terms of test response spectra, to Seismic Margin Studies and Probabilistic Risk Assessments is discussed and specific recommendations are provided

  8. Aerobic Capacity and Anaerobic Power Levels of the University Students

    Science.gov (United States)

    Taskin, Cengiz

    2016-01-01

    The aim of study was to analyze aerobic capacity and anaerobic power levels of the university students. Total forty university students who is department physical education and department business (age means; 21.15±1.46 years for male and age means; 20.55±1.79 years for female in department physical education), volunteered to participate in this…

  9. Design of megawatt power level heat pipe reactors

    Energy Technology Data Exchange (ETDEWEB)

    Mcclure, Patrick Ray [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Poston, David Irvin [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dasari, Venkateswara Rao [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Reid, Robert Stowers [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-12

    An important niche for nuclear energy is the need for power at remote locations removed from a reliable electrical grid. Nuclear energy has potential applications at strategic defense locations, theaters of battle, remote communities, and emergency locations. With proper safeguards, a 1 to 10-MWe (megawatt electric) mobile reactor system could provide robust, self-contained, and long-term power in any environment. Heat pipe-cooled fast-spectrum nuclear reactors have been identified as a candidate for these applications. Heat pipe reactors, using alkali metal heat pipes, are perfectly suited for mobile applications because their nature is inherently simpler, smaller, and more reliable than “traditional” reactors. The goal of this project was to develop a scalable conceptual design for a compact reactor and to identify scaling issues for compact heat pipe cooled reactors in general. Toward this goal two detailed concepts were developed, the first concept with more conventional materials and a power of about 2 MWe and a the second concept with less conventional materials and a power level of about 5 MWe. A series of more qualitative advanced designs were developed (with less detail) that show power levels can be pushed to approximately 30 MWe.

  10. Float level switch for a nuclear power plant containment vessel

    International Nuclear Information System (INIS)

    Powell, J.G.

    1993-01-01

    This invention is a float level switch used to sense rise or drop in water level in a containment vessel of a nuclear power plant during a loss of coolant accident. The essential components of the device are a guide tube, a reed switch inside the guide tube, a float containing a magnetic portion that activates a reed switch, and metal-sheathed, ceramic-insulated conductors connecting the reed switch to a monitoring system outside the containment vessel. Special materials and special sealing techniques prevent failure of components and allow the float level switch to be connected to a monitoring system outside the containment vessel. 1 figures

  11. Float level switch for a nuclear power plant containment vessel

    Science.gov (United States)

    Powell, James G.

    1993-01-01

    This invention is a float level switch used to sense rise or drop in water level in a containment vessel of a nuclear power plant during a loss of coolant accident. The essential components of the device are a guide tube, a reed switch inside the guide tube, a float containing a magnetic portion that activates a reed switch, and metal-sheathed, ceramic-insulated conductors connecting the reed switch to a monitoring system outside the containment vessel. Special materials and special sealing techniques prevent failure of components and allow the float level switch to be connected to a monitoring system outside the containment vessel.

  12. Evaluation of power commissioning of the Mochovce Unit 1 power level up to 100 % Nnom

    International Nuclear Information System (INIS)

    Sarvaic, I.; Mickolci, M.

    1998-01-01

    The document contains an evaluation of the power phase of power commissioning of the Mochovce Unit 1 in the phase up to the power level of 100 % N nom .In the document, the courses and results of tests in this phase of power commissioning are summarized, evaluation of the performance of important systems and equipment of the unit is carried out, and the compliance with Limits and Conditions in the course of the phase is assessed. On this basis, conclusions are drawn and recommendations for the unit to be ready for subsequent phases of the power commissioning. The evaluation was developed by the scientific management of the Mochovce commissioning providing an independent support for the operators for supervising the commissioning tasks from the point of nuclear safety

  13. Technical impacts of high penetration levels of wind power on power system stability

    OpenAIRE

    Flynn, Damian; Rather, Z.; Ardal, Atle; Darco, Salvatore; Hansen, Anca Daniela; Cutululis, Nicolaos Antonio; Sørensen, Poul Ejnar; Estanqueiro, Ana; Gomez, Emilio; Menemenlis, Nickie; Smith, Charlie; Wang, Ye

    2017-01-01

    With increasing penetrations of wind generation, based on power-electronic converters, power systems are transitioning away from well-understood synchronous generator-based systems, with growing implications for their stability. Issues of concern will vary with system size, wind penetration level, geographical distribution and turbine type, network topology, electricity market structure, unit commitment procedures, and other factors. However, variable-speed wind turbines, both onshore and con...

  14. Genotoxicity of Heterocyclic PAHs in the Micronucleus Assay with the Fish Liver Cell Line RTL-W1

    Science.gov (United States)

    Brinkmann, Markus; Blenkle, Henning; Salowsky, Helena; Bluhm, Kerstin; Schiwy, Sabrina; Tiehm, Andreas; Hollert, Henner

    2014-01-01

    Heterocyclic aromatic hydrocarbons are, together with their un-substituted analogues, widely distributed throughout all environmental compartments. While fate and effects of homocyclic PAHs are well-understood, there are still data gaps concerning the ecotoxicology of heterocyclic PAHs: Only few publications are available investigating these substances using in vitro bioassays. Here, we present a study focusing on the identification and quantification of clastogenic and aneugenic effects in the micronucleus assay with the fish liver cell line RTL-W1 that was originally derived from rainbow trout (Oncorhynchus mykiss). Real concentrations of the test items after incubation without cells were determined to assess chemical losses due to, e.g., sorption or volatilization, by means of gas chromatography-mass spectrometry. We were able to show genotoxic effects for six compounds that have not been reported in vertebrate systems before. Out of the tested substances, 2,3-dimethylbenzofuran, benzothiophene, quinoline and 6-methylquinoline did not cause substantial induction of micronuclei in the cell line. Acridine caused the highest absolute induction. Carbazole, acridine and dibenzothiophene were the most potent substances compared with 4-nitroquinoline oxide, a well characterized genotoxicant with high potency used as standard. Dibenzofuran was positive in our investigation and tested negative before in a mammalian system. Chemical losses during incubation ranged from 29.3% (acridine) to 91.7% (benzofuran) and may be a confounding factor in studies without chemical analyses, leading to an underestimation of the real potency. The relative potency of the investigated substances was high compared with their un-substituted PAH analogues, only the latter being typically monitored as priority or indicator pollutants. Hetero-PAHs are widely distributed in the environment and even more mobile, e.g. in ground water, than homocyclic PAHs due to the higher water solubility. We

  15. Genotoxicity of heterocyclic PAHs in the micronucleus assay with the fish liver cell line RTL-W1.

    Directory of Open Access Journals (Sweden)

    Markus Brinkmann

    Full Text Available Heterocyclic aromatic hydrocarbons are, together with their un-substituted analogues, widely distributed throughout all environmental compartments. While fate and effects of homocyclic PAHs are well-understood, there are still data gaps concerning the ecotoxicology of heterocyclic PAHs: Only few publications are available investigating these substances using in vitro bioassays. Here, we present a study focusing on the identification and quantification of clastogenic and aneugenic effects in the micronucleus assay with the fish liver cell line RTL-W1 that was originally derived from rainbow trout (Oncorhynchus mykiss. Real concentrations of the test items after incubation without cells were determined to assess chemical losses due to, e.g., sorption or volatilization, by means of gas chromatography-mass spectrometry. We were able to show genotoxic effects for six compounds that have not been reported in vertebrate systems before. Out of the tested substances, 2,3-dimethylbenzofuran, benzothiophene, quinoline and 6-methylquinoline did not cause substantial induction of micronuclei in the cell line. Acridine caused the highest absolute induction. Carbazole, acridine and dibenzothiophene were the most potent substances compared with 4-nitroquinoline oxide, a well characterized genotoxicant with high potency used as standard. Dibenzofuran was positive in our investigation and tested negative before in a mammalian system. Chemical losses during incubation ranged from 29.3% (acridine to 91.7% (benzofuran and may be a confounding factor in studies without chemical analyses, leading to an underestimation of the real potency. The relative potency of the investigated substances was high compared with their un-substituted PAH analogues, only the latter being typically monitored as priority or indicator pollutants. Hetero-PAHs are widely distributed in the environment and even more mobile, e.g. in ground water, than homocyclic PAHs due to the higher water

  16. Radio frequency plasma nitriding of aluminium at higher power levels

    International Nuclear Information System (INIS)

    Gredelj, Sabina; Kumar, Sunil; Gerson, Andrea R.; Cavallaro, Giuseppe P.

    2006-01-01

    Nitriding of aluminium 2011 using a radio frequency plasma at higher power levels (500 and 700 W) and lower substrate temperature (500 deg. C) resulted in higher AlN/Al 2 O 3 ratios than obtained at 100 W and 575 deg. C. AlN/Al 2 O 3 ratios derived from X-ray photoelectron spectroscopic analysis (and corroborated by heavy ion elastic recoil time of flight spectrometry) for treatments preformed at 100 (575 deg. C), 500 (500 deg. C) and 700 W (500 deg. C) were 1.0, 1.5 and 3.3, respectively. Scanning electron microscopy revealed that plasma nitrided surfaces obtained at higher power levels exhibited much finer nodular morphology than obtained at 100 W

  17. A Rotating Speed Controller Design Method for Power Levelling by Means of Inertia Energy in Wind Power Systems

    DEFF Research Database (Denmark)

    Qin, Zian; Blaabjerg, Frede; Loh, Poh Chiang

    2015-01-01

    Power fluctuation caused by wind speed variations may be harmful for the stability of the power system as well as the reliability of the wind power converter, since it may induce thermal excursions in the solder joints of the power modules. Using the wind turbine rotor inertia energy for power...... in the frequency domain for power leveling. Moreover, the impact of other parameters on power leveling, including the time constant of maximum power point tracking (MPPT) and the rotor inertia, are also studied. With the proposed optimal design, the power fluctuations are mitigated as much as possible, while...

  18. Extended Pulse-Powered Humidity-Freeze Cycling for Testing Module-Level Power Electronics

    Energy Technology Data Exchange (ETDEWEB)

    Hacke, Peter L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Rodriguez, Miguel [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Kempe, Michael D [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Repins, Ingrid L [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-28

    An EMI suppression capacitor (polypropylene film type) failed by 'popcorning' due to vapor outgassing in pulse powered humidity-freeze cycles. No shorts or shunts could be detected despite mildly corroded metallization visible in the failed capacitor. Humidity-freeze cycling is optimized to break into moisture barriers. However, further studies will be required on additional module level power electronic (MLPE) devices to optimize the stress testing for condensation to precipitate any weakness to short circuiting and other humidity/bias failure modes.

  19. A New RTL Design Approach for a DCT/IDCT-Based Image Compression Architecture using the mCBE Algorithm

    Directory of Open Access Journals (Sweden)

    Rachmad Vidya Wicaksana Putra

    2013-09-01

    Full Text Available In  the  literature, several approaches  of  designing  a  DCT/IDCT-based image compression system have been proposed.  In this paper,  we present a new RTL design approach with as main  focus developing a  DCT/IDCT-based image compression  architecture  using  a  self-created  algorithm.  This  algorithm  can efficiently  minimize  the  amount  of  shifter -adders  to  substitute  multiplier s.  We call  this  new  algorithm  the  multiplication  from  Common  Binary  Expression (mCBE  Algorithm. Besides this algorithm, we propose alternative quantization numbers,  which  can  be  implemented  simply  as  shifters  in  digital  hardware. Mostly, these numbers can retain a good compressed-image quality  compared to JPEG  recommendations.  These  ideas  lead  to  our  design  being  small  in  circuit area,  multiplierless,  and  low  in  complexity.  The  proposed  8-point  1D-DCT design  has  only  six  stages,  while  the  8-point  1D-IDCT  design  has  only  seven stages  (one  stage  being  defined as  equal  to  the  delay  of  one  shifter  or  2-input adder. By using the pipelining method, we can achieve a high-speed architecture with latency as    a  trade-off consideration. The  design has been synthesized and can reach a speed of up to 1.41ns critical path delay (709.22MHz. 

  20. Effect of reactor conditions on MSIV-ATWS power level

    International Nuclear Information System (INIS)

    Diamond, D.J.

    1987-01-01

    In a boiling water reactor (BWR) when there is closure of the main steam isolation valves (MSIVs), the energy generated in the core will be transferred to the pressure suppression pool (PSP) via steam that flows out of the relief valves. The pool has limited capacity as a heat sink and hence, if there is no reactor trip [an anticipated transient without scram (ATWS) event], there is the possibility that the pool temperature may rise beyond acceptable limits. The present study was undertaken to determine how the initial reactor conditions affect the power level during an MSIV-ATWS event. The time of interest is the 20- to 30-min period when it is assumed that the reactor is in a quasi equilibrium condition with the water level and pressure fixed, natural circulation conditions and no control rod movement or significant boron in the core. The initial conditions of interest are the time of the cycle and the operating state

  1. Management of the high-level nuclear power facilities

    International Nuclear Information System (INIS)

    Preda, Marin

    2003-05-01

    This thesis approaches current issues in the management of the high power nuclear facilities and as such it appears to be important particularly for nuclear power plant operation topics. Of special interest are the failure events entailing possible catastrophic situations. The contents is structured onto ten chapters. The first chapter describes the operation regimes of the nuclear high power facilities. Highlighted here are the thesis scope and the original features of the work. The second chapter deals with operational policies developed in order to ensure the preventive maintenance of the nuclear installations. Also managing structures are described devoted to practical warranting the equipment safety function of non-classical power stations. In the third chapter cases of nuclear accidents are analyzed especially stressing the probabilistic risk and the operation regimes having in view the elimination of catastrophic events. In the fourth and fifth chapters the control of nuclear radiation emission is treated focusing the quality issue of nuclear installations required to avoid hazardous effects at level of nuclear reactor operation stage. At the same time set of operational measures is given here for preventing risks, catastrophes and chaotic situations. The chapter five presents both theoretical and practical approaches of the nuclear reactor core management concerning particularly the fuel testing, the water primary system and the quality of the involved equipment. In the sixth and seventh chapters issues of risk-quality correlations are approached as well as the structure of expert systems for monitoring the operational regimes of nuclear facilities. The efficiency of the power systems with nuclear injection is discussed and some original ideas developed in this work are evidenced in the eighth and ninth chapters. Presented are here both the operational principles and models of raising the efficiency of the interconnected nuclear stations and prices' policy

  2. Technical basis for staffing levels at nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Shurberg, D.A.; Haber, S.B. [Brookhaven National Lab., Upton, NY (United States); Morisseau, D. [Nuclear Regulatory Commission, Washington, DC (United States)] [and others

    1995-04-01

    The objective of this project is to provide a technical basis for the establishment of criteria for minimum staffing levels of licensed and non-licensed NPP shift personnel. Minimum staffing levels for the purpose of this study, are defined as those necessary for successful accomplishment of all safety and additional functions that must be performed in order for the licensee to meet applicable regulatory requirements. This project involves a multi-faceted approach to the investigation of the issue. Relevant NRC documentation was identified and reviewed. Using the information obtained from this documentation review, a test plan was developed to aid in the collection of further information regarding the adequacy of current shift staffing levels. The test plan addresses three different activities to be conducted to provide information to the NRC for use in the assessment of current minimum staffing levels. The first activity is collection of data related to industry shift staffing practices through site visits to seven nuclear power plants. The second activity is a simulator study, which will use licensed operator crews responding to a simulated event, under two different staffing levels. Finally, workload models will be constructed for both licensed and non-licensed personnel, using a priori knowledge of the simulator scenarios with data resulting from one of the staffing levels studied in the simulator, and the data collected from the site visits. The model will then be validated against the data obtained from the second staffing level studied in the simulator. The validated model can then be used to study the impact of changing staffing-related variables on the plant shift crew`s ability to effectively mitigate an event.

  3. Design of an optimal automatic regulator for regulating the power levels of a nuclear reactor in a wind power range

    International Nuclear Information System (INIS)

    Noori Khajavi, M.; Menhaj, M.B.; Ghofrani, M.B.

    2000-01-01

    Nuclear power reactors are, in nature nonlinear and time varying. These characteristics must be considered, if large power variations occur in their working regime. In this paper a robust optimal self-tuning regulator for regulating the power of a nuclear reactor has been designed and simulated. The proposed controller is capable of regulating power levels in a wide power range (10% to 100% power levels). The controller achieves a fast and good transient response. The simulation results show that the proposed controller outperforms the fixed optimal control recently cited in the literature for nuclear power plants

  4. Power estimation on functional level for programmable processors

    Directory of Open Access Journals (Sweden)

    M. Schneider

    2004-01-01

    Full Text Available In diesem Beitrag werden verschiedene Ansätze zur Verlustleistungsschätzung von programmierbaren Prozessoren vorgestellt und bezüglich ihrer Übertragbarkeit auf moderne Prozessor-Architekturen wie beispielsweise Very Long Instruction Word (VLIW-Architekturen bewertet. Besonderes Augenmerk liegt hierbei auf dem Konzept der sogenannten Functional-Level Power Analysis (FLPA. Dieser Ansatz basiert auf der Einteilung der Prozessor-Architektur in funktionale Blöcke wie beispielsweise Processing-Unit, Clock-Netzwerk, interner Speicher und andere. Die Verlustleistungsaufnahme dieser Bl¨ocke wird parameterabhängig durch arithmetische Modellfunktionen beschrieben. Durch automatisierte Analyse von Assemblercodes des zu schätzenden Systems mittels eines Parsers können die Eingangsparameter wie beispielsweise der erzielte Parallelitätsgrad oder die Art des Speicherzugriffs gewonnen werden. Dieser Ansatz wird am Beispiel zweier moderner digitaler Signalprozessoren durch eine Vielzahl von Basis-Algorithmen der digitalen Signalverarbeitung evaluiert. Die ermittelten Schätzwerte für die einzelnen Algorithmen werden dabei mit physikalisch gemessenen Werten verglichen. Es ergibt sich ein sehr kleiner maximaler Schätzfehler von 3%. In this contribution different approaches for power estimation for programmable processors are presented and evaluated concerning their capability to be applied to modern digital signal processor architectures like e.g. Very Long InstructionWord (VLIW -architectures. Special emphasis will be laid on the concept of so-called Functional-Level Power Analysis (FLPA. This approach is based on the separation of the processor architecture into functional blocks like e.g. processing unit, clock network, internal memory and others. The power consumption of these blocks is described by parameter dependent arithmetic model functions. By application of a parser based automized analysis of assembler codes of the systems to be estimated

  5. Power estimation on functional level for programmable processors

    Science.gov (United States)

    Schneider, M.; Blume, H.; Noll, T. G.

    2004-05-01

    In diesem Beitrag werden verschiedene Ansätze zur Verlustleistungsschätzung von programmierbaren Prozessoren vorgestellt und bezüglich ihrer Übertragbarkeit auf moderne Prozessor-Architekturen wie beispielsweise Very Long Instruction Word (VLIW)-Architekturen bewertet. Besonderes Augenmerk liegt hierbei auf dem Konzept der sogenannten Functional-Level Power Analysis (FLPA). Dieser Ansatz basiert auf der Einteilung der Prozessor-Architektur in funktionale Blöcke wie beispielsweise Processing-Unit, Clock-Netzwerk, interner Speicher und andere. Die Verlustleistungsaufnahme dieser Bl¨ocke wird parameterabhängig durch arithmetische Modellfunktionen beschrieben. Durch automatisierte Analyse von Assemblercodes des zu schätzenden Systems mittels eines Parsers können die Eingangsparameter wie beispielsweise der erzielte Parallelitätsgrad oder die Art des Speicherzugriffs gewonnen werden. Dieser Ansatz wird am Beispiel zweier moderner digitaler Signalprozessoren durch eine Vielzahl von Basis-Algorithmen der digitalen Signalverarbeitung evaluiert. Die ermittelten Schätzwerte für die einzelnen Algorithmen werden dabei mit physikalisch gemessenen Werten verglichen. Es ergibt sich ein sehr kleiner maximaler Schätzfehler von 3%. In this contribution different approaches for power estimation for programmable processors are presented and evaluated concerning their capability to be applied to modern digital signal processor architectures like e.g. Very Long InstructionWord (VLIW) -architectures. Special emphasis will be laid on the concept of so-called Functional-Level Power Analysis (FLPA). This approach is based on the separation of the processor architecture into functional blocks like e.g. processing unit, clock network, internal memory and others. The power consumption of these blocks is described by parameter dependent arithmetic model functions. By application of a parser based automized analysis of assembler codes of the systems to be estimated the input

  6. Dynamic evaluation of the levelized cost of wind power generation

    International Nuclear Information System (INIS)

    Díaz, Guzmán; Gómez-Aleixandre, Javier; Coto, José

    2015-01-01

    Highlights: • Conventional levelized cost of energy is static and does not consider flexibility. • This paper defines a dynamic version by means of stochastic programming. • A penalty for early exercising is proposed to differentiate static and dynamic. • Results show the effects of feed-in tariff support in low wind sites. • Policy implications are derived on the basis of the static and dynamic measures. - Abstract: This paper discusses an alternative computation method of the levelized cost of energy of distributed wind power generators. Unlike in the conventional procedures, it includes time of commencement as an optimization variable. For that purpose, a methodology from Longstaff and Schwartz’s dynamic program for pricing financial American options is derived, which provides the ability to find the optimum time and value while coping with uncertainty revenues from energy sales and variable capital costs. The results obtained from the analysis of wind records of 50 sites entail that the conventional levelized cost of energy can be broken down into an optimum, minimum (time-dependent) value and a penalty for early exercising, which can be employed to define investment strategies and support policies

  7. CEA contribution to power plant operation with high burnup level

    International Nuclear Information System (INIS)

    1981-03-01

    High level burnup in PWR leads to investigate again the choices carried out in the field of fuel management. French CEA has studied the economic importance of reshuffling technique, cycle length, discharge burnup, and non-operation period between two cycles. Power plants operators wish to work with increased length cycles of 18 months instead of 12. That leads to control problems because the core reactivity cannot be controlled with the only soluble boron: moderator temperature coefficient must be negative. With such cycles, it is necessary to use burnable poisons and for economic reasons with a low penalty in end of cycle. CEA has studied the use of Gd 2 O 3 mixed with fuel or with inert element like Al 2 O 3 . Parametric studies of specific weights, efficacities relatively to the fuel burnup and the fuel enrichment have been carried out. Particular studies of 1 month cycles with Gd 2 O 3 have shown the possibility to control power distribution with a very low reactivity penalty in EOC. In the same time, in the 100 MW PWR-CAP, control reactivity has been made with large use of gadolinia in parallel with soluble boron for the two first cycles

  8. New reactor safety circuit for low-power-level operation

    International Nuclear Information System (INIS)

    McDowell, W.P.; Keefe, D.J.; Rusch, G.K.

    1978-01-01

    In the operation of nuclear reactors at low-power levels, one of the primary instrumentation problems is that the statistical fluctuations of reactor neutron population are accentuated by conventional log-count-rate and differentiating circuits and can cause frequent spurious scrams unless long time constants are incorporated in the circuit. Excessive time constants may introduce undesirable delay in the circuit response to legitimate scram signals. The paper develops the concept of a count doubling-time monitor which generates a scram signal if the number of counts from a pulse type neutron detector doubles in a given period of time. The paper demonstrates the theoretical relation between count doubling time and asymptomatic periods. A practical circuit to implement the function is described

  9. Quarkonium level fitting with two-power potentials

    International Nuclear Information System (INIS)

    Joshi, G.C.; Wignall, J.W.G.

    1981-01-01

    An attempt has been made to fit psi and UPSILON energy levels and leptonic decay width ratios with a non-relativistic potential model using a potential of the form V(r) = Arsup(p) + Brsup(q) + C. It is found that reasonable fits to states below hadronic decay threshold can be obtained for values of the powers p and q anywhere along a family of curves in the (p,q) plane that smoothly join the Martin potential (p = 0, q = 0.1) to the potential forms with p approximately -1 suggested by QCD; for the latter case the best fit is obtained with q approximately 0.4 - 0.5

  10. Experimental study of rectenna coupling at low power level

    International Nuclear Information System (INIS)

    Douyère, A; Alicalapa, F; Lan Sun Luk, J-D; Rivière, S

    2013-01-01

    The experimental results presented in this paper focus on the performance of a rectenna array by studying the effect of mutual coupling between two rectennas. The measurements in several planes of the space are investigated and used to help us to define the minimum distance for future rectenna arrays that can be used at a low power density level. The single element chosen for the array is composed of a rectifier circuit and a CSPA (Circular Slot Patch Antenna). This study shows that at a distance greater than 6cm (λ/2) between two rectennas in reception, we observe that the DC received voltage is constant in the Y plane, while in the X plane, the DC received voltage remains constant whatever the distance. We deduce that these rectennas are uncoupled in this case. We can consider each rectenna like an independent system.

  11. Technical impacts of high penetration levels of wind power on power system stability

    DEFF Research Database (Denmark)

    Flynn, Damian; Rather, Z.; Ardal, Atle

    2017-01-01

    With increasing penetrations of wind generation, based on power-electronic converters, power systems are transitioning away from well-understood synchronous generator-based systems, with growing implications for their stability. Issues of concern will vary with system size, wind penetration level......, geographical distribution and turbine type, network topology, electricity market structure, unit commitment procedures, and other factors. However, variable-speed wind turbines, both onshore and connected offshore through DC grids, offer many control opportunities to either replace or enhance existing...... capabilities. Achieving a complete understanding of future stability issues, and ensuring the effectiveness of new measures and policies, is an iterative procedure involving portfolio development and flexibility assessment, generation cost simulations, load flow, and security analysis, in addition...

  12. In vitro cytotoxic and teratogenic potential of sediment extracts from Skadar Lake using fish cell line RTL-W1 and Danio rerio embryos

    Directory of Open Access Journals (Sweden)

    Perović Andrej

    2013-01-01

    Full Text Available As a part of Sediment Quality Triad (SQT, organic extracts of sediment from Skadar Lake (a Mediterranean lake and the largest freshwater reservoir in southeastern Europe were investigated in order to evaluate possible ecotoxicological contamination by organic pollutants and to obtain a comprehensive insight into the ecotoxicological hazard. Sediments were investigated for toxicity by two different bioassays. Acute cytotoxicity was investigated using the fibroblast-like cell line RTL-W1 (Oncorhynchus mykiss in combination with the neutral red retention assay. The embryos of zebrafish (Danio rerio were used to assess the toxic and teratogenic potential of organic extracts of the sediment. Preliminary results point to the presence of a cytotoxic and teratogenic potential in Skadar Lake sediment extracts in certain locations.

  13. A Study of KHNP Nuclear Power Plant Technology Level Evaluation

    International Nuclear Information System (INIS)

    Yang, Seung Han; Lee, Sung Jin; Kim, Yo Han

    2016-01-01

    KHNP's 2030 mid and long term plan goal in technology field is securing global No. 1 NPP technology level. Quantifying technology level for this purpose, technology level at present should be surveyed. Technology level of South Korea has been surveyed by KISTEP (Korea Institute of S and T Evaluation and Planning) every two year but the technology level of KHNP has not been surveyed by any organization including KHNP itself. Also the size of technology surveyed by KISTEP was too broad to quantifying technology level of KHNP. In this paper, technology level of KHNP and South Korea are presented. In this study, NPP related technologies were divided into Level I and Level II technologies and conducted a survey for each Level II technologies using Delphi questionnaire survey that is widely used in technology level evaluation. The results of technology level and gap will be used from strategic point of view and also as a reference data for technology improvement planning

  14. A Study of KHNP Nuclear Power Plant Technology Level Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Seung Han; Lee, Sung Jin; Kim, Yo Han [KHNP, Daejeon (Korea, Republic of)

    2016-05-15

    KHNP's 2030 mid and long term plan goal in technology field is securing global No. 1 NPP technology level. Quantifying technology level for this purpose, technology level at present should be surveyed. Technology level of South Korea has been surveyed by KISTEP (Korea Institute of S and T Evaluation and Planning) every two year but the technology level of KHNP has not been surveyed by any organization including KHNP itself. Also the size of technology surveyed by KISTEP was too broad to quantifying technology level of KHNP. In this paper, technology level of KHNP and South Korea are presented. In this study, NPP related technologies were divided into Level I and Level II technologies and conducted a survey for each Level II technologies using Delphi questionnaire survey that is widely used in technology level evaluation. The results of technology level and gap will be used from strategic point of view and also as a reference data for technology improvement planning.

  15. Feminized Power and Adversarial Advocacy: Levelling Arguments or Analyzing Them?

    Science.gov (United States)

    Condit, Celeste Michelle

    1989-01-01

    Examines the journalistic analysis of the 1988 Presidential Debates from a feminist perspective in order to identify the revisions needed in the debate process. Provides historical background of feminized power and adversarial advocacy. (MM)

  16. Empirical LTE Smartphone Power Model with DRX Operation for System Level Simulations

    DEFF Research Database (Denmark)

    Lauridsen, Mads; Noël, Laurent; Mogensen, Preben

    2013-01-01

    An LTE smartphone power model is presented to enable academia and industry to evaluate users’ battery life on system level. The model is based on empirical measurements on a smartphone using a second generation LTE chipset, and the model includes functions of receive and transmit data rates...... and power levels. The first comprehensive Discontinuous Reception (DRX) power consumption measurements are reported together with cell bandwidth, screen and CPU power consumption. The transmit power level and to some extent the receive data rate constitute the overall power consumption, while DRX proves...

  17. Draft emergency action level guidelines for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1979-09-15

    This document is provided for interim use during the initial phases of the NRC effort to promptly improve emergency preparedness at operating nuclear power plants. Changes to the document can be expected as experience is gained in its use and public comments are received. Further, the Commission has initiated a rulemaking procedure, now scheduled for completion in January 1930 in the area of Emergency Planning and Preparedness. Additional requirements are to be expected when rulemaking is completed and some modifications to this document may be necessary. Four classes of Emergency Action Levels are established which replace the classes in Regulatory Guide 1.101, each with associated examples of initiating conditions. The classes are: - Notification of Unusual Event; - Alert; - Site Emergency; - General Emergency. The rationale for the notification and alert classes is to provide early and prompt notification of minor events which could lead to more serious consequences given operator error or equipment failure or which might be indicative of more serious conditions which are not yet fully realized. A gradation is provided to assure fuller response preparations for more serious indicators. The site emergency class reflects conditions where some significant releases are likely or are occurring but where a core melt situation is not indicated based on current information. In this situation full mobilization of emergency personnel in tie :near site environs is indicated as well as dispatch of monitoring teams and associated communications. The general emergency class involves actual or imminent substantial core degradation or malting with the potential for loss of containment. The immediate action for this class is sheltering (staying inside) rather thai evacuation until an assessment can be made that (1) an evacuation is indicated and (2) an evacuation, if indicated, can be completed prior to significant release and transport of radioactive material to the affected

  18. Draft emergency action level guidelines for nuclear power plants

    International Nuclear Information System (INIS)

    1979-09-01

    This document is provided for interim use during the initial phases of the NRC effort to promptly improve emergency preparedness at operating nuclear power plants. Changes to the document can be expected as experience is gained in its use and public comments are received. Further, the Commission has initiated a rulemaking procedure, now scheduled for completion in January 1930 in the area of Emergency Planning and Preparedness. Additional requirements are to be expected when rulemaking is completed and some modifications to this document may be necessary. Four classes of Emergency Action Levels are established which replace the classes in Regulatory Guide 1.101, each with associated examples of initiating conditions. The classes are: - Notification of Unusual Event; - Alert; - Site Emergency; - General Emergency. The rationale for the notification and alert classes is to provide early and prompt notification of minor events which could lead to more serious consequences given operator error or equipment failure or which might be indicative of more serious conditions which are not yet fully realized. A gradation is provided to assure fuller response preparations for more serious indicators. The site emergency class reflects conditions where some significant releases are likely or are occurring but where a core melt situation is not indicated based on current information. In this situation full mobilization of emergency personnel in tie :near site environs is indicated as well as dispatch of monitoring teams and associated communications. The general emergency class involves actual or imminent substantial core degradation or malting with the potential for loss of containment. The immediate action for this class is sheltering (staying inside) rather thai evacuation until an assessment can be made that (1) an evacuation is indicated and (2) an evacuation, if indicated, can be completed prior to significant release and transport of radioactive material to the affected

  19. Power Grid Construction Project Portfolio Optimization Based on Bi-level programming model

    Science.gov (United States)

    Zhao, Erdong; Li, Shangqi

    2017-08-01

    As the main body of power grid operation, county-level power supply enterprises undertake an important emission to guarantee the security of power grid operation and safeguard social power using order. The optimization of grid construction projects has been a key issue of power supply capacity and service level of grid enterprises. According to the actual situation of power grid construction project optimization of county-level power enterprises, on the basis of qualitative analysis of the projects, this paper builds a Bi-level programming model based on quantitative analysis. The upper layer of the model is the target restriction of the optimal portfolio; the lower layer of the model is enterprises’ financial restrictions on the size of the enterprise project portfolio. Finally, using a real example to illustrate operation proceeding and the optimization result of the model. Through qualitative analysis and quantitative analysis, the bi-level programming model improves the accuracy and normative standardization of power grid enterprises projects.

  20. BEST-4, Fuel Cycle and Cost Optimization for Discrete Power Levels

    International Nuclear Information System (INIS)

    1973-01-01

    1 - Nature of physical problem solved: Determination of optimal power strategy for a fuel cycle, for discrete power levels and n temporal stages, taking into account replacement energy costs and de-rating. 2 - Method of solution: Dynamic programming. 3 - Restrictions on the complexity of the problem: Restrictions may arise from number of power levels and temporal stages, due to machine limitations

  1. Bi-Level Decentralized Active Power Control for Large-Scale Wind Farm Cluster

    DEFF Research Database (Denmark)

    Huang, Shengli; Wu, Qiuwei; Guo, Yifei

    2018-01-01

    This paper presents a bi-level decentralized active power control (DAPC) for a large-scale wind farm cluster, consisting of several wind farms for better active power dispatch. In the upper level, a distributed active power control scheme based on the distributed consensus is designed to achieve...... fair active power sharing among multiple wind farms, which generates the power reference for each wind farm. A distributed estimator is used to estimate the total available power of all wind farms. In the lower level, a centralized control scheme based on the Model Predictive Control (MPC) is proposed...... to regulate active power outputs of all wind turbines (WTs) within a wind farm, which reduces the fatigue loads of WTs while tracking the power reference obtained from the upper level control. A wind farm cluster with 8 wind farms and totally 160 WTs, was used to test the control performance of the proposed...

  2. Theoretical parameter histories of dynamic tests during power commissioning of Mochovce units power level up to 100 % Nnom

    International Nuclear Information System (INIS)

    Jagrik, J.; Mraz, M.; Rapant, M.; Stefanovic, P.; Kotasek, J.; Gieci, A.; Macko, J.; Mosny, J.

    1998-01-01

    Theoretical histories of selected parameters for dynamic tests carried out in the course of power commissioning of the Mochovce Unit 1 at the power level 100% N nom are shown in the report. The expected histories given were developed based on calculations performed by means of simulator in Nuclear Power Plants Research Institute Trnava, Inc., simulator in EGU Praha and simulator at the Mochovce plant, as well as based on similar tests at both Bohunice and Dukovany plants

  3. The advantages and disadvantages of centralized control of air power at operational level

    Science.gov (United States)

    Arisoy, Uǧur

    2014-05-01

    People do not want to see and hear a war. In today's world, if war is inevitable, the use of air power is seen as the preferable means of conducting operations instead of financially burdensome land battles which are more likely to cause heavy loss of life. The use of Air Power has gained importance in NATO operations in the Post-Cold War era. For example, air power has undertaken a decisive role from the beginning to the end of the operation in Libya. From this point of view, the most important issue to consider is how to direct air power more effectively at operational level. NATO's Core JFAC (Joint Force Air Command) was established in 2012 to control joint air power at operational level from a single center. US had experienced JFAC aproach in the Operation Desert Storm in 1991. UK, France, Germany, Italy and Spain are also directing their air power from their JFAC structures. Joint air power can be directed from a single center at operational level by means of JFAC. JFAC aproach provides complex planning progress of Air Power to be controled faster in a single center. An Air Power with a large number of aircrafts, long range missiles of cutting-edge technology may have difficulties in achieving results unless directed effectively. In this article, directing air power more effectively at operational level has been studied in the framework of directing air power from a single center carried out by SWOT analysis technique. "Directing Air Power at operational level from a single center similar to JFAC-like structure" is compared with "Directing Air Power at operational level from two centers similar to AC (Air Command) + CAOC (Combined Air Operations Center) structure" As a result of this study, it is assessed that directing air power at operational level from a single center would bring effectiveness to the air campaign. The study examines directing air power at operational level. Developments at political, strategic and tactical levels have been ignored.

  4. High system-safety level of nuclear power stations

    International Nuclear Information System (INIS)

    Lutz, H.R.

    1976-01-01

    A bluntly worded disquisition contrasting the incidence of death and harm to persons in the chemical industry with the low hazards in nuclear power stations. Quotes conclusions from a U.S. accident study that the risk from 100 large power stations is 100 times smaller than from chlorine manufacture and transport. The enclosure of a reactor in a safety container, the well understood effects of radioactivity on man, and the ease of measuring leakage well below safe limits, are safety features which he considers were not matched in the products and plant of the Seveso factory which suffered disaster. Questions the usefulness of warnings about nuclear dangers when chemical dangers are much greater and road dangers very much greater still. (R.W.S.)

  5. Photovoltaic Shading Testbed for Module-Level Power Electronics

    Energy Technology Data Exchange (ETDEWEB)

    Deline, C.; Meydbray, J.; Donovan, M.; Forrest, J.

    2012-05-01

    This document describes a repeatable test procedure that attempts to simulate shading situations, as would be experienced by typical residential rooftop photovoltaic (PV) systems. This type of shading test is particularly useful to evaluate the impact of different power conversion setups, including microinverters, DC power optimizers and string inverters, on overall system performance. The performance results are weighted based on annual estimates of shade to predict annual performance improvement. A trial run of the test procedure was conducted with a side by side comparison of a string inverter with a microinverter, both operating on identical 8kW solar arrays. Considering three different shade weighting conditions, the microinverter was found to increase production by 3.7% under light shading, 7.8% under moderate shading, and 12.3% under heavy shading, relative to the reference string inverter case. Detail is provided in this document to allow duplication of the test method at different test installations and for different power electronics devices.

  6. Analog phase lock between two lasers at LISA power levels

    International Nuclear Information System (INIS)

    Diekmann, Christian; Steier, Frank; Sheard, Benjamin; Heinzel, Gerhard; Danzmann, Karsten

    2009-01-01

    This paper presents the implementation of an analog optical phase-locked-loop with an offset frequency of about 20MHz between two lasers, where the detected light powers were of the order of 31 pW and 200 μW. The goal of this setup was the design and characterization of a photodiode transimpedance amplifier for application in LISA. By application of a transimpedance amplifier designed to have low noise and low power consumption, the phase noise between the two lasers was a factor of two above the shot noise limit down to 60mHz. The achievable phase sensitivity depends ultimately on the available power of the highly attenuated master laser and on the input current noise of the transimpedance amplifier of the photodetector. The limiting noise source below 60mHz was the analog phase measurement system that was used in this experiment. A digital phase measurement system that is currently under development at the AEI will be used in the near future. Its application should improve the sensitivity.

  7. Analog phase lock between two lasers at LISA power levels

    Energy Technology Data Exchange (ETDEWEB)

    Diekmann, Christian; Steier, Frank; Sheard, Benjamin; Heinzel, Gerhard; Danzmann, Karsten, E-mail: Christian.Diekmann@aei.mpg.d [Max-Planck-Institute for Gravitational Physics, Callinstr. 38, D-30167 Hannover (Germany)

    2009-03-01

    This paper presents the implementation of an analog optical phase-locked-loop with an offset frequency of about 20MHz between two lasers, where the detected light powers were of the order of 31 pW and 200 muW. The goal of this setup was the design and characterization of a photodiode transimpedance amplifier for application in LISA. By application of a transimpedance amplifier designed to have low noise and low power consumption, the phase noise between the two lasers was a factor of two above the shot noise limit down to 60mHz. The achievable phase sensitivity depends ultimately on the available power of the highly attenuated master laser and on the input current noise of the transimpedance amplifier of the photodetector. The limiting noise source below 60mHz was the analog phase measurement system that was used in this experiment. A digital phase measurement system that is currently under development at the AEI will be used in the near future. Its application should improve the sensitivity.

  8. Level shifter for low power applications with body bias technique

    African Journals Online (AJOL)

    user

    In present work three new designs of level shifter in 0.35µm technology using body ... level shifters, namely conventional type-I, conventional type-II and contention mitigated have been improved by varying the ..... single-chip mobile processor.

  9. The vitrification of high level wastes using microwave power

    International Nuclear Information System (INIS)

    Hardwick, W.H.; Gayler, R.; Murphy, V.

    1981-01-01

    A process for radioactive waste vitrification which exploits advantages peculiar to microwave heating is under development. The advantages claimed are the removal of the heat source from the radioactive environment, the elimination of heat transfer barriers by direct coupling of the energy with the process materials, and the ability to evaporate liquors absorbed in a glass fibre matrix which constitutes the glass forming additive. This glass fibre matrix which constitutes the glass forming additive. This glass fibre is also used to filter off-gases and give a condensate free of solids. The fibre loaded with dried waste is converted to a homogeneous glass by melting using microwave power. (orig./DG)

  10. Low-level radioactive waste processing at nuclear power plants

    International Nuclear Information System (INIS)

    1992-12-01

    This survey was limited to systems and materials used to process waste liquids contaminated with radionuclides. Since the chemical and radiological character of collected liquids may change dramatically, the survey describes waste and cleanup process streams encountered during normal outage or power production conditions. Influents containing specific organic compounds, salts, or solids common to local sources, and the special techniques developed to remove or concentrate these materials are not detailed in this report. The names and phone numbers of the individuals responsible for investigating and solving these problems, however, provides easy access to data which will save time and expense when facing abnormal processing, purchasing, or engineering challenges. The Liquid Radwaste Source Book contains information collected from 31 of 36 BWR's as well as contact information from all licensed commercial units. Since some sites share common radwaste processing facilities, not all units are represented by individual data sheets

  11. Power quality enhancement at distribution level utilizing the unified power quality conditioner (UPQC)

    Science.gov (United States)

    Khadkikar, Vinod

    The present doctoral work is based on the philosophy of optimal utilization of the available resources in a most effective and efficient way to improve the product efficiency and to reduce the overall cost. This work proposes a novel control philosophy termed as power angle control (PAC), in which both the series and shunt inverters share the load reactive power in co-ordination with each other without affecting the basic UPQC compensation capabilities. This eventually results in a better utilization of the series inverter, reduction in the shunt inverter rating to some extent and ultimately in the reduction of the overall cost of UPQC. Moreover, in this thesis work several other control approaches are also proposed, such as, unit vector template generation, quadrature voltage injection, generalized single-phase p-q theory and novel current unbalance compensation approach. All the developed concepts are successfully validated through digital simulation as well as extensive experimental investigations. Keywords. power quality, active power filter, unified power quality conditioner, reactive power compensation, harmonics compensation.

  12. Power Analysis for Cross Level Mediation in CRTs

    Science.gov (United States)

    Kelcey, Ben

    2014-01-01

    A common design in education research for interventions operating at a group or cluster level is a cluster randomized trial (CRT) (Bloom, 2005). In CRTs, intact clusters (e.g., schools) are assigned to treatment conditions rather than individuals (e.g., students) and are frequently an effective way to study interventions because they permit…

  13. A supermolecular building layer approach for gas separation and storage applications: the eea and rtl MOF platforms for CO 2 capture and hydrocarbon separation

    KAUST Repository

    Chen, Zhijie

    2015-02-11

    The supermolecular building layer (SBL) approach was employed to deliberately synthesize five novel metal–organic frameworks (1–5) with an exposed array of amide or amine functionalities within their pore system. The ability to decorate the pores with nitrogen donor moieties offers potential to evaluate/elucidate the structure–adsorption property relationship. Two MOF platforms, eea-MOF and rtl-MOF, based on pillaring of kgm-a or sql-a layers with heterofunctional 3-connected organic building blocks were targeted and constructed to purposely introduce and expose the desired amide or amine functionalities. Interestingly, gas adsorption properties of eea-MOF-4 (1) and eea-MOF-5 (2) showed that by simply altering the nitrogen donor position within the ligand, it is possible to relatively reduce the pore size of the related eea-MOF material and subsequently increase the associated CO2 uptake. The slightly confined pore space in 2, relative to 1, has enabled an enhancement of the pore local charge density and thus the observed relative increase in the CO2 and H2 isosteric heat of adsorption (Qst). In addition, light hydrocarbon adsorption studies revealed that 2 is more selective toward C2H6 and C3H8 over CH4 than 1, as exemplified for C2H6 : CH4 (5 : 95) or C3H8 : CH4 (5 : 95) binary gas mixtures.

  14. Deadbeat control of power leveling unit with bidirectional buck/boost DC/DC converter

    OpenAIRE

    Hamasaki, Shin-ichi; Mukai, Ryosuke; Yano, Yoshihiro; Tsuji, Mineo

    2014-01-01

    As a distributed generation system increases, a stable power supply becomes difficult. Thus control of power leveling (PL) unit is required to maintain the balance of power flow for irregular power generation. The unit is required to respond to change of voltage and bidirectional power flow. So the bidirectional buck/boost DC/DC converter is applied for the control of PL unit in this research. The PL unit with Electric double-layer capacitor (EDLC) is able to absorb change of power, and it is...

  15. ACCOUNTING OF REACTIVE POWER COMPENSATION LEVEL AT PAYMENT CALCULATION OF TECHNOLOGICAL CONSUMPTION (LOSSES OF ELECTRIC POWER FOR ITS TRANSMISSION IN POWER NETWORK

    Directory of Open Access Journals (Sweden)

    E. P. Zabello

    2005-01-01

    Full Text Available The method is proposed to make a correction in payment for consumption of reactive energy and power which is attributed to deviation of actual activation energy losses for reactive power compensation from their standard value. It is recommended to calculate standard loss values for every voltage level and actual loss values are to be determined with the help of application of remote electronic accounting means in the current mode of power consumption.

  16. The Power of Individual-level Drivers of Inventive Performance

    DEFF Research Database (Denmark)

    Zwick, Thomas; Frosch, Katharina; Hoisl, Karin

    2017-01-01

    (KSAO) model. We link survey information spanning the inventors’ entire careers and psychometric test evidence with patent history data for more than 1000 inventors. We also control for variables that have traditionally been used in studies of inventive performance including inventor age, applicant type......, technology, patent, and time information. We show that educational level, skills acquired during the career, personality traits, career motivation, cognitive ability, and cognitive problem-solving style are significantly related to inventive performance....

  17. Power levels in office equipment: Measurements of new monitors and personal computers

    International Nuclear Information System (INIS)

    Roberson, Judy A.; Brown, Richard E.; Nordman, Bruce; Webber, Carrie A.; Homan, Gregory H.; Mahajan, Akshay; McWhinney, Marla; Koomey, Jonathan G.

    2002-01-01

    Electronic office equipment has proliferated rapidly over the last twenty years and is projected to continue growing in the future. Efforts to reduce the growth in office equipment energy use have focused on power management to reduce power consumption of electronic devices when not being used for their primary purpose. The EPA ENERGY STAR[registered trademark] program has been instrumental in gaining widespread support for power management in office equipment, and accurate information about the energy used by office equipment in all power levels is important to improving program design and evaluation. This paper presents the results of a field study conducted during 2001 to measure the power levels of new monitors and personal computers. We measured off, on, and low-power levels in about 60 units manufactured since July 2000. The paper summarizes power data collected, explores differences within the sample (e.g., between CRT and LCD monitors), and discusses some issues that arise in m etering office equipment. We also present conclusions to help improve the success of future power management programs.Our findings include a trend among monitor manufacturers to provide a single very low low-power level, and the need to standardize methods for measuring monitor on power, to more accurately estimate the annual energy consumption of office equipment, as well as actual and potential energy savings from power management

  18. Uncertainty and power at low levels of incurred radiation dose

    International Nuclear Information System (INIS)

    Wilson, M; Jackson, D

    2005-01-01

    It is common practice when calculating dose to exposed populations to average the variables that go into the dose calculation (e.g. environmental concentrations, air kerma, consumption rates, occupancy rates). This approach is simple and can be useful where data are obtained over different periods (weekly, monthly, quarterly), where samples may be bulked for some analyses but not others and where gaps in the data are present. However, such an approach does not yield information on the degree of uncertainty around the average dose calculated. An alternative approach is to estimate the dose to each individual and to obtain an average from this data set, which can then also be used to derive a measure of uncertainty around the central dose estimate. In this study, we demonstrate the variability in dose estimates using a hypothetical data set and consider the implications for sample size to achieve fixed confidence or resolving power. We recommend calculating the dose to every individual sampled, in order both to obtain the average dose and to estimate its variability. We argue that it is best practice to obtain information as complete as possible from the available sample of individuals

  19. User instructions for levelized power generation cost codes using an IBM-type PC

    International Nuclear Information System (INIS)

    Coen, J.J.; Delene, J.G.

    1989-01-01

    Programs for the calculation of levelized power generation costs using an IBM or compatible PC are described. Cost calculations for nuclear plants and coal-fired plants include capital investment cost, operation and maintenance cost, fuel cycle cost, decommissioning cost, and total levelized power generation cost. 7 refs., 36 figs., 4 tabs

  20. Nuclear power plant personnel entry level qualifications and training

    International Nuclear Information System (INIS)

    Jorgensen, C.C.; Haas, P.M.; Selby, D.L.; Lowry, J.C.

    1983-01-01

    This paper summarizes the early results and current status of a research program at ORNL which is intended to provide the methods and technical basis for NRC to initiate the use of the Systems Approach to Training (SAT) in the evaluation of training programs and entry level qualifications for NPP control room personnel. The program is an outgrowth of previous studies of simulator hardware and simulator training requirements under the Safety Related Operator Actions Program which recommended adaptation of a systems methodology to development and evaluation of NPP training programs

  1. Operating the Irish power system with increased levels of wind power

    DEFF Research Database (Denmark)

    Tuohy, A.; Denny, E.; Meibom, Peter

    2008-01-01

    This paper summarises some of the main impacts of large amounts of wind power installed in the island of Ireland. Using results from various studies performed on this system, it is shown that wind power will impact on all time frames, from seconds to daily planning of the system operation. Results...... from studies examining operation of the system with up to approximately 40% of electricity provided by wind show that some of the most important aspects to be considered include the type of wind turbine technology, the provision of reserve to accommodate wind forecasting error and the method used...

  2. PSA Level 2:Scope And Method Of PSA Level 2 For Nuclear Power Plant

    International Nuclear Information System (INIS)

    Widodo, Surip; Antariksawan, Anhar R.

    2001-01-01

    A study of scope and method of PSA Level 2 had been conducted. The background of the study is the need to gain the capability to well perform PSA Level 2 for nuclear facilities. This study is a literature survey. The scope of PSA Level 2 consists of generating plant damage states, accident progression analysis, and grouping source terms. Concerning accident progression analysis, several methods are used, among others event tree method, named accident progression event tree (APET) or containment event tree (CET), and fault tree method. The end result of PSA Level 2 is release end states which is grouped into release bins. The results will be used for PSA Level 3

  3. Effects of lignocellulosic composition and microwave power level on the gaseous product of microwave pyrolysis

    International Nuclear Information System (INIS)

    Huang, Yu-Fong; Chiueh, Pei-Te; Kuan, Wen-Hui; Lo, Shang-Lien

    2015-01-01

    Agricultural residues are abundant resources to produce renewable energy and valuable chemicals. This study focused on the effects of lignocellulosic composition and microwave power level on the gaseous product of microwave pyrolysis of agricultural residues. When agricultural residues were under microwave radiation within 10 min, the maximum temperatures of approximately 320, 420, and 530 °C were achieved at the microwave power levels of 300, 400, and 500 W, respectively. Gas yield increased with increasing microwave power level, whereas solid and liquid yields decreased. Besides, gaseous products with higher H 2 content and higher calorific values can be obtained at higher microwave power levels. In addition to microwave power level, lignocellulosic composition was also an important factor. H 2 and CO 2 yields increased with increasing hemicellulose content, whereas CH 4 and CO yields increased with increasing cellulose content. Four empirical equations were derived to present the contributions of lignocellulosic materials to the yields of gaseous components. - Highlights: • About 530 °C was reached within 10 min at a microwave power level of 500 W. • Gas yield increased with increasing microwave power level. • A high correlation between hemicellulose content and either H 2 or CO 2 yield. • A high correlation between cellulose content and either CH 4 or CO yield. • Empirical equations depict contribution of lignocellulosic content to gas yield

  4. Core design experience of WWER-440 reactors when they working on increased power level

    International Nuclear Information System (INIS)

    Adeev, V.; Panov, A.; Melenchuk, I.

    2015-01-01

    The Kola NPP continues commercial operation of 2nd generation fuel (FA-2) and trial operation of 3rd generation fuel (FA-3), which has a number of design features providing the best operational characteristics. This report gives the results of VVER-440 core operation with FA-2 and FA-3 with enrichment increased up to 4.87%, and at the power level uprated to 107% of nominal power level. Brief analysis of obtained data is carried out. Peculiarities and techniques of developing loading patterns with new types of nuclear fuel for operation at the uprated power level are reviewed. (authors)

  5. Exposure to runoff from coal-tar-sealed pavement induces genotoxicity and impairment of DNA repair capacity in the RTL-W1 fish liver cell line.

    Science.gov (United States)

    Kienzler, Aude; Mahler, Barbara J; Van Metre, Peter C; Schweigert, Nathalie; Devaux, Alain; Bony, Sylvie

    2015-07-01

    Coal-tar-based (CTB) sealcoat, frequently applied to parking lots and driveways in North America, contains elevated concentrations of polycyclic aromatic hydrocarbons (PAHs) and related compounds. The RTL-W1 fish liver cell line was used to investigate two endpoints (genotoxicity and DNA-repair-capacity impairment) associated with exposure to runoff from asphalt pavement with CTB sealcoat or with an asphalt-based sealcoat hypothesized to contain about 7% CTB sealcoat (AS-blend). Genotoxic potential was assessed by the Formamido pyrimidine glycosylase (Fpg)-modified comet assay for 1:10 and 1:100 dilutions of runoff samples collected from 5 h to 36 d following sealcoat application. DNA-repair capacity was assessed by the base excision repair comet assay for 1:10 dilution of samples collected 26 h and 36 d following application. Both assays were run with and without co-exposure to ultraviolet-A radiation (UVA). With co-exposure to UVA, genotoxic effects were significant for both dilutions of CTB runoff for three of four sample times, and for some samples of AS-blend runoff. Base excision repair was significantly impaired for CTB runoff both with and without UVA exposure, and for AS-blend runoff only in the absence of UVA. This study is the first to investigate the effects of exposure to the complex mixture of chemicals in coal tar on DNA repair capacity. The results indicate that co-exposure to runoff from CT-sealcoated pavement and UVA as much as a month after sealcoat application has the potential to cause genotoxicity and impair DNA repair capacity. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Some heterocyclic aromatic compounds are Ah receptor agonists in the DR-CALUX assay and the EROD assay with RTL-W1 cells.

    Science.gov (United States)

    Hinger, Gunnar; Brinkmann, Markus; Bluhm, Kerstin; Sagner, Anne; Takner, Helena; Eisenträger, Adolf; Braunbeck, Thomas; Engwall, Magnus; Tiehm, Andreas; Hollert, Henner

    2011-09-01

    Heterocyclic aromatic compounds containing nitrogen, sulfur, or oxygen heteroatoms (NSO-HET) have been detected in air, soil, marine, and freshwater systems. However, only few publications are available investigating NSO-HET using in vitro bioassays. To support better characterization of environmental samples, selected NSO-HET were screened for dioxin-like activity in two bioassays. The present study focuses on the identification and quantification of dioxin-like effects of 12 NSO-HET using the DR-CALUX assay, and the 7-ethoxyresorufin-O-deethylase (EROD) assay with the permanent fish liver cell line RTL-W1. Changes of the total medium compound concentrations during the test procedure due to, e.g., sorption or volatilization were quantified using GC/MS. The NSO-HET benzofuran, 2,3-dimethylbenzofuran, dibenzofuran, dibenzothiophen, acridine, xanthene, and carbazole caused a response in the DR-CALUX assay. Only benzofuran and 2,3-dimethylbenzofuran were also positive in the EROD assay. All other compounds were inactive in the EROD assay. Relative potency (REP) values ranged from (2.80 ± 1.32) · 10(-8) to (3.26 ± 2.03) · 10(-6) in the DR-CALUX and from (3.26 ± 0.91) · 10(-7) to (4.87 ± 1.97) · 10(-7) in the EROD assay. The REP values were comparable to those of larger polycyclic aromatic hydrocarbons, e.g., fluoranthene and pyrene. Thus, and because of the ubiquitous distribution of heterocyclic aromatic compounds in the environment, the provided data will further facilitate the bioanalytical and analytical characterization of environmental samples towards these toxicants.

  7. Exposure to runoff from coal-tar-sealed pavement induces genotoxicity and impairment of DNA repair capacity in the RTL-W1 fish liver cell line

    Science.gov (United States)

    Kienzler, Aude; Mahler, Barbara J.; Van Metre, Peter C.; Schweigert, Nathalie; Devaux, Alain; Bony, Sylvie

    2015-01-01

    Coal-tar-based (CTB) sealcoat, frequently applied to parking lots and driveways in North America, contains elevated concentrations of polycyclic aromatic hydrocarbons (PAHs) and related compounds. The RTL-W1 fish liver cell line was used to investigate two endpoints (genotoxicity and DNA-repair-capacity impairment) associated with exposure to runoff from asphalt pavement with CTB sealcoat or with an asphalt-based sealcoat hypothesized to contain about 7% CTB sealcoat (AS-blend). Genotoxic potential was assessed by the Formamido pyrimidine glycosylase (Fpg)-modified comet assay for 1:10 and 1:100 dilutions of runoff samples collected from 5 h to 36 d following sealcoat application. DNA-repair capacity was assessed by the base excision repair comet assay for 1:10 dilution of samples collected 26 h and 36 d following application. Both assays were run with and without co-exposure to ultraviolet-A radiation (UVA). With co-exposure to UVA, genotoxic effects were significant for both dilutions of CTB runoff for three of four sample times, and for some samples of AS-blend runoff. Base excision repair was significantly impaired for CTB runoff both with and without UVA exposure, and for AS-blend runoff only in the absence of UVA. This study is the first to investigate the effects of exposure to the complex mixture of chemicals in coal tar on DNA repair capacity. The results indicate that co-exposure to runoff from CT-sealcoated pavement and UVA as much as a month after sealcoat application has the potential to cause genotoxicity and impair DNA repair capacity.

  8. The Level of Power Quality Measurement and Evaluation in A Stone Crusher Plant

    Directory of Open Access Journals (Sweden)

    Mustafa ŞEKKELİ

    2009-03-01

    Full Text Available Both electric utilities and end users of electric power are becoming increasingly concerned about the quality of electric power. Quality of electrical energy in the electrical system that is requested continuous power (uninterrupted power, constant frequency and with constant amplitude can be explained by sinusoidal voltage. Deformation of voltage in the form of sinusoidal waveform is explained as a harmonic. Harmonics are most important factors in decreasing quality of energy in the electrical system. In industrial plants, existence of harmocins and voltage drop, causes serious problems both in plant and network. This problem affects the cost. In this study, a power quality measurements are carried out in stone crusher plant. Harmonics and voltage drop has been measured and evaluated with the power analyzer. In the power quality measurements, harmonic level of the plant is not so bad. However, it is recommended that compensation system with harmonic elimination can be established in plant.

  9. Building America Case Study: Photovoltaic Systems with Module-Level Power Electronics

    Energy Technology Data Exchange (ETDEWEB)

    2015-09-01

    Direct current (DC) power optimizers and microinverters (together known as module-level power electronics, or MLPE) are one of the fastest growing market segments in the solar industry. According to GTM Research in The Global PV Inverter Landscape 2015, over 55% of all residential photovoltaic (PV) installations in the United States used some form of MLPE in 2014.

  10. Integrating High Levels of Variable Renewable Energy into Electric Power Systems

    Energy Technology Data Exchange (ETDEWEB)

    Kroposki, Benjamin D. [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-08-01

    As more variable renewable energy is integrated into electric power systems, there are a range of challenges and solutions to accommodating very high penetration levels. This presentation highlights some of the recent research in this area.

  11. 77 FR 20059 - License Amendment To Increase the Maximum Reactor Power Level, Florida Power & Light Company...

    Science.gov (United States)

    2012-04-03

    ... reduce and mitigate salinity levels in groundwater; operational changes to the PTN cooling canal system... approving the proposed expansion of PTN Units 3 and 4 based on compliance with conditions required by the... restrooms would be used during plant modifications. Therefore, land use conditions would not change at the...

  12. Impact of coal combustion from thermal power plant: estimates on ambient SO2 levels

    International Nuclear Information System (INIS)

    Joshi, P.V.

    1991-01-01

    Using a Gaussian dispersion model, ambient Ground Levels Concentrations (GLC) of SO 2 due to Nashik Thermal Power Plant have been computed. Annual GLC in 16 cardinal sectors and concentration levels in 6 atmospheric stability classes have been estimated as a function of down wind distance. The values are compared with national ambient air quality standard and risk involved due to the release of SO 2 from power plant has been assessed. (author). 8 refs., 2 appendixes

  13. Thermal analysis of two-level wind power converter under symmetrical grid fault

    DEFF Research Database (Denmark)

    Zhou, Dao; Blaabjerg, Frede

    2013-01-01

    In this paper, the case of symmetrical grid fault when using the multi-MW wind turbine of partial-scale and full-scale two-level power converter are designed and investigated. Firstly, the different operation behaviors of the relevant power converters under the voltage dip will be described......) condition as well as the junction temperature. For the full-scale wind turbine system, the most thermal stressed power device in the grid-side converter will appear at the grid voltage below 0.5 pu, and for the partial-scale wind turbine system, the most thermal stressed power device in the rotor...

  14. System Level Power Optimization of Digital Audio Back End for Hearing Aids

    DEFF Research Database (Denmark)

    Pracny, Peter; Jørgensen, Ivan Harald Holger; Bruun, Erik

    2017-01-01

    This work deals with power optimization of the audio processing back end for hearing aids - the interpolation filter (IF), the sigma-delta (SD modulator and the Class D power amplifier (PA) as a whole. Specifications are derived and insight into the tradeoffs involved is used to optimize...... the interpolation filter and the SD modulator on the system level so that the switching frequency of the Class D PA - the main power consumer in the back end - is minimized. A figure-of-merit (FOM) which allows judging the power consumption of the digital part of the back end early in the design process is used...

  15. Modular Multi-level converter based HVDC System for Grid Connection of Offshore Wind Power Plant

    DEFF Research Database (Denmark)

    Gnanarathna, U.N.; Chaudhary, Sanjay Kumar; Gole, A.M.

    2010-01-01

    This paper explores the application of modular multi-level converters (MMC) as a means for harnessing the power from off-shore wind power plants. The MMC consists of a large number of simple voltage sourced converter (VSC) submodules that can be easily assembled into a converter for high......-voltage and high power. The paper shows that the MMC converter has a fast response and low harmonic content in comparison with a two-level VSC option. The paper discusses the modeling approach used, including a solution to the modeling challenge imposed by the very large number of switching devices in the MMC....

  16. The Level of Difficulty and Discrimination Power of the Basic Knowledge and Skills Examination (EXHCOBA.

    Directory of Open Access Journals (Sweden)

    Eduardo Backhoff Escudero

    2000-05-01

    Full Text Available The Basic Knowledge and Skills Examination (EXHCOBA is one of the few great-scale examinations in Mexico which has been publishing its psychometric parameters.  In this paper we describe the  item analysis results, regarding the exam’s difficulty level and discrimination power.  Results show that most of the items have a medium difficulty and a high discrimination power.  They also reveal that the mathematics items have better discrimination power levels than the ones which belong to social science.

  17. Lifetime Estimation of Electrolytic Capacitors in Fuel Cell Power Converter at Various Confidence Levels

    DEFF Research Database (Denmark)

    Zhou, Dao; Wang, Huai; Blaabjerg, Frede

    2016-01-01

    DC capacitors in power electronic converters are a major constraint on improvement of the power density and the reliability. In this paper, according to the degradation data of tested capacitors, the lifetime model of the component is analyzed at various confidence levels. Then, the mission profile...... based lifetime expectancy of the individual capacitor and the capacitor bank is estimated in a fuel cell backup power converter operating in both standby mode and operation mode. The lifetime prediction of the capacitor banks at different confidence levels is also obtained....

  18. Power level effects on thorium-based fuels in pressure-tube heavy water reactors

    Energy Technology Data Exchange (ETDEWEB)

    Bromley, B.P.; Edwards, G.W.R., E-mail: blair.bromley@cnl.ca [Canadian Nuclear Laboratories, Chalk River, Ontario (Canada); Sambavalingam, P. [Univ. of Ontario Inst. of Technology, Oshawa, Ontario (Canada)

    2016-06-15

    Lattice and core physics modeling and calculations have been performed to quantify the impact of power/flux levels on the reactivity and achievable burnup for 35-element fuel bundles made with Pu/Th or U-233/Th. The fissile content in these bundles has been adjusted to produce on the order of 20 MWd/kg burnup in homogeneous cores in a 700 MWe-class pressure-tube heavy water reactor, operating on a once-through thorium cycle. Results demonstrate that the impact of the power/flux level is modest for Pu/Th fuels but significant for U-233/Th fuels. In particular, high power/flux reduces the breeding and burnup potential of U-233/Th fuels. Thus, there may be an incentive to operate reactors with U-233/Th fuels at a lower power density or to develop alternative refueling schemes that will lower the time-average specific power, thereby increasing burnup.(author)

  19. System-level Reliability Assessment of Power Stage in Fuel Cell Application

    DEFF Research Database (Denmark)

    Zhou, Dao; Wang, Huai; Blaabjerg, Frede

    2016-01-01

    reliability. In a case study of a 5 kW fuel cell power stage, the parameter variations of the lifetime model prove that the exponential factor of the junction temperature fluctuation is the most sensitive parameter. Besides, if a 5-out-of-6 redundancy is used, it is concluded both the B10 and the B1 system......High efficient and less pollutant fuel cell stacks are emerging and strong candidates of the power solution used for mobile base stations. In the application of the backup power, the availability and reliability hold the highest priority. This paper considers the reliability metrics from...... the component-level to the system-level for the power stage used in a fuel cell application. It starts with an estimation of the annual accumulated damage for the key power electronic components according to the real mission profile of the fuel cell system. Then, considering the parameter variations in both...

  20. Power level effects on thorium-based fuels in pressure-tube heavy water reactors

    International Nuclear Information System (INIS)

    Bromley, B.P.; Edwards, G.W.R.; Sambavalingam, P.

    2016-01-01

    Lattice and core physics modeling and calculations have been performed to quantify the impact of power/flux levels on the reactivity and achievable burnup for 35-element fuel bundles made with Pu/Th or U-233/Th. The fissile content in these bundles has been adjusted to produce on the order of 20 MWd/kg burnup in homogeneous cores in a 700 MWe-class pressure-tube heavy water reactor, operating on a once-through thorium cycle. Results demonstrate that the impact of the power/flux level is modest for Pu/Th fuels but significant for U-233/Th fuels. In particular, high power/flux reduces the breeding and burnup potential of U-233/Th fuels. Thus, there may be an incentive to operate reactors with U-233/Th fuels at a lower power density or to develop alternative refueling schemes that will lower the time-average specific power, thereby increasing burnup.(author)

  1. A Note on Comparing the Power of Test Statistics at Low Significance Levels.

    Science.gov (United States)

    Morris, Nathan; Elston, Robert

    2011-01-01

    It is an obvious fact that the power of a test statistic is dependent upon the significance (alpha) level at which the test is performed. It is perhaps a less obvious fact that the relative performance of two statistics in terms of power is also a function of the alpha level. Through numerous personal discussions, we have noted that even some competent statisticians have the mistaken intuition that relative power comparisons at traditional levels such as α = 0.05 will be roughly similar to relative power comparisons at very low levels, such as the level α = 5 × 10 -8 , which is commonly used in genome-wide association studies. In this brief note, we demonstrate that this notion is in fact quite wrong, especially with respect to comparing tests with differing degrees of freedom. In fact, at very low alpha levels the cost of additional degrees of freedom is often comparatively low. Thus we recommend that statisticians exercise caution when interpreting the results of power comparison studies which use alpha levels that will not be used in practice.

  2. `Power storage system` dealing with leveling of electric power use; Denryoku riyo no heijunka ni kotaeru `denryoku chozo system`

    Energy Technology Data Exchange (ETDEWEB)

    Igarashi, M. [Meidensha Corp., Tokyo (Japan)

    1996-06-28

    An overview is given on the development situation of a Zn-Br battery as a power storage system. The system is aimed at storing excess power at night and supplying the on-load demand during daytime. The power storage technology requires a large output and capacity of MWh level, long term stability and durability, and cost as low as pumped storage power generation. Four kinds of batteries have been examined to cope with the conditions, in which development of Zn-Br batteries along with Na-S batteries is in progress towards practicability. As a power conversion method for this system, GTO has been employed for a large capacity unit and IGBT for a medium/small capacity unit. The reliability of the Zn-Br batteries against leakage was improved by laminating each cell by hot plate welding. The service life was improved by using a material with a high bromine resistance in place of the conventional electrode constituent material. Although the battery efficiency was influenced by each resistance of electrode, film and electrolytic solution, distance between electrodes, temperature, etc., these correlations were clarified so as to establish the simulation technology. At present, the system realizes 50kW and 40kWh/m{sup 3}. 1 ref., 8 figs.

  3. Four-level time decomposition quasi-static power flow and successive disturbances analysis. [Power system disturbances

    Energy Technology Data Exchange (ETDEWEB)

    Jovanovic, S M [Nikola Tesla Inst., Belgrade (YU)

    1990-01-01

    This paper presents a model and an appropriate numerical procedure for a four-level time decomposition quasi-static power flow and successive disturbances analysis of power systems. The analysis consists of the sequential computation of the zero, primary, secondary and tertiary quasi-static states and of the estimation of successive structural disturbances during the 1200 s dynamics after a structural disturbance. The model is developed by detailed inspection of the time decomposition characteristics of automatic protection and control devices. Adequate speed of the numerical procedure is attained by a specific application of the inversion matrix lemma and the decoupled model constant coefficient matrices. The four-level time decomposition quasi-static method is intended for security and emergency analysis. (author).

  4. Evaluation of BWROG EPG level/power control strategy for Vermont Yankee

    International Nuclear Information System (INIS)

    Chandola, V.; Robichaud, J.D.

    1987-01-01

    The current Boiling Water Reactor Owner's Group (BWROG) emergency procedure guidelines (EPGs) direct reactor operators to manually lower the reactor pressure vessel (RPV) water level to the top of active fuel (TAF) during an anticipated transient without scram (ATWS) event. Lowering the water level reduces the core inlet flow, thereby reducing core power. However, reducing water level is contrary to current operator training, which requires that normal RPV water level be maintained to assure core cooling. In addition, the indicated water level near TAF using cold calibrated level instrumentation may not be reliable, which could potentially result in uncovering the core. This paper evaluates the EPGs' level/power control strategy for the Vermont Yankee plant and proposes alternative to the BWROG guidelines as applied to ATWS response

  5. Power Flow Control through a Multi-Level H-Bridge-based Power Converter for Universal and Flexible Power Management in Future Electrical Grids

    DEFF Research Database (Denmark)

    Iov, Florin; Bifaretti, Steffano; Zanchetta, Pericle

    2008-01-01

    The paper proposes a novel power conversion system for Universal and Flexible Power Management (UNIFLEX-PM) in Future Electricity Network. The structure is based on three AC-DC converters each one connected to a different grid, (representing the main grid and/or various distributed generation...... systems) on the AC side, and linked together at DC side by suitable DC isolation modules. Each port of the UNIFLEX-PM system employs a conversion structure based on a three-phase 7-level AC-DC cascaded converter. Effective and accurate power flow control is demonstrated through simulation in Matlab...... and Simulink environment on a simplified model based on a two-port structure and using a Stationery Reference Frame based control solution. Control of different Power flow profiles has been successfully tested in numerous network conditions such as voltage unbalance, frequency excursions and harmonic...

  6. Multiple external hazards compound level 3 PSA methods research of nuclear power plant

    Science.gov (United States)

    Wang, Handing; Liang, Xiaoyu; Zhang, Xiaoming; Yang, Jianfeng; Liu, Weidong; Lei, Dina

    2017-01-01

    2011 Fukushima nuclear power plant severe accident was caused by both earthquake and tsunami, which results in large amount of radioactive nuclides release. That accident has caused the radioactive contamination on the surrounding environment. Although this accident probability is extremely small, once such an accident happens that is likely to release a lot of radioactive materials into the environment, and cause radiation contamination. Therefore, studying accidents consequences is important and essential to improve nuclear power plant design and management. Level 3 PSA methods of nuclear power plant can be used to analyze radiological consequences, and quantify risk to the public health effects around nuclear power plants. Based on multiple external hazards compound level 3 PSA methods studies of nuclear power plant, and the description of the multiple external hazards compound level 3 PSA technology roadmap and important technical elements, as well as taking a coastal nuclear power plant as the reference site, we analyzed the impact of off-site consequences of nuclear power plant severe accidents caused by multiple external hazards. At last we discussed the impact of off-site consequences probabilistic risk studies and its applications under multiple external hazards compound conditions, and explained feasibility and reasonableness of emergency plans implementation.

  7. Wafer-level chip-scale packaging analog and power semiconductor applications

    CERN Document Server

    Qu, Shichun

    2015-01-01

    This book presents a state-of-art and in-depth overview in analog and power WLCSP design, material characterization, reliability, and modeling. Recent advances in analog and power electronic WLCSP packaging are presented based on the development of analog technology and power device integration. The book covers in detail how advances in semiconductor content, analog and power advanced WLCSP design, assembly, materials, and reliability have co-enabled significant advances in fan-in and fan-out with redistributed layer (RDL) of analog and power device capability during recent years. Along with new analog and power WLCSP development, the role of modeling is a key to assure successful package design. An overview of the analog and power WLCSP modeling and typical thermal, electrical, and stress modeling methodologies is also provided. This book also: ·         Covers the development of wafer-level power discrete packaging with regular wafer-level design concepts and directly bumping technology ·    �...

  8. User's manual for levelized power generation cost using an IBM PC

    International Nuclear Information System (INIS)

    Fuller, L.C.

    1985-06-01

    Programs for the estimation of levelized electric power generation costs using the BASIC interpreter on an IBM PC are described. Procedures for light-water reactor plants and coal-fired plants include capital investment cost, operation and maintenance cost, fuel cycle cost, nuclear decommissioning cost, and levelized total generation cost

  9. Multi-Level Risk Assessment of a Power Plant Gas Turbine Applying ...

    African Journals Online (AJOL)

    Multi-Level Risk Assessment of a Power Plant Gas Turbine Applying the Criticality Index Model. ... Journal of the Nigerian Association of Mathematical Physics ... This study has carefully shown and expressed a step by step computation of the severity level of the Turbine component parts, using the Criticality Index model.

  10. A high-level power model for MPSoC on FPGA

    NARCIS (Netherlands)

    Piscitelli, R.; Pimentel, A.D.

    2011-01-01

    This paper presents a framework for high-level power estimation of multiprocessor systems-on-chip (MPSoC) architectures on FPGA. The technique is based on abstract execution profiles, called event signatures, and it operates at a higher level of abstraction than, e.g., commonly-used instruction-set

  11. Hybrid PV/diesel solar power system design using multi-level factor analysis optimization

    Science.gov (United States)

    Drake, Joshua P.

    Solar power systems represent a large area of interest across a spectrum of organizations at a global level. It was determined that a clear understanding of current state of the art software and design methods, as well as optimization methods, could be used to improve the design methodology. Solar power design literature was researched for an in depth understanding of solar power system design methods and algorithms. Multiple software packages for the design and optimization of solar power systems were analyzed for a critical understanding of their design workflow. In addition, several methods of optimization were studied, including brute force, Pareto analysis, Monte Carlo, linear and nonlinear programming, and multi-way factor analysis. Factor analysis was selected as the most efficient optimization method for engineering design as it applied to solar power system design. The solar power design algorithms, software work flow analysis, and factor analysis optimization were combined to develop a solar power system design optimization software package called FireDrake. This software was used for the design of multiple solar power systems in conjunction with an energy audit case study performed in seven Tibetan refugee camps located in Mainpat, India. A report of solar system designs for the camps, as well as a proposed schedule for future installations was generated. It was determined that there were several improvements that could be made to the state of the art in modern solar power system design, though the complexity of current applications is significant.

  12. Exposure to runoff from coal-tar-sealed pavement induces genotoxicity and impairment of DNA repair capacity in the RTL-W1 fish liver cell line

    International Nuclear Information System (INIS)

    Kienzler, Aude; Mahler, Barbara J.; Van Metre, Peter C.; Schweigert, Nathalie; Devaux, Alain; Bony, Sylvie

    2015-01-01

    Coal-tar-based (CTB) sealcoat, frequently applied to parking lots and driveways in North America, contains elevated concentrations of polycyclic aromatic hydrocarbons (PAHs) and related compounds. The RTL-W1 fish liver cell line was used to investigate two endpoints (genotoxicity and DNA-repair-capacity impairment) associated with exposure to runoff from asphalt pavement with CTB sealcoat or with an asphalt-based sealcoat hypothesized to contain about 7% CTB sealcoat (AS-blend). Genotoxic potential was assessed by the Formamido pyrimidine glycosylase (Fpg)-modified comet assay for 1:10 and 1:100 dilutions of runoff samples collected from 5 h to 36 d following sealcoat application. DNA-repair capacity was assessed by the base excision repair comet assay for 1:10 dilution of samples collected 26 h and 36 d following application. Both assays were run with and without co-exposure to ultraviolet-A radiation (UVA). With co-exposure to UVA, genotoxic effects were significant for both dilutions of CTB runoff for three of four sample times, and for some samples of AS-blend runoff. Base excision repair was significantly impaired for CTB runoff both with and without UVA exposure, and for AS-blend runoff only in the absence of UVA. This study is the first to investigate the effects of exposure to the complex mixture of chemicals in coal tar on DNA repair capacity. The results indicate that co-exposure to runoff from CT-sealcoated pavement and UVA as much as a month after sealcoat application has the potential to cause genotoxicity and impair DNA repair capacity. - Highlights: • Co-exposure to runoff from coal-tar-sealcoated pavement and UVA caused DNA damage. • Significant genotoxicity occurred with a 1:100 dilution of runoff. • Runoff collected up to 36 d following coal-tar-sealcoat application was genotoxic. • Exposure to runoff from sealed pavement impaired an important DNA repair pathway. • Repair capacity was impaired with a 1:10 dilution of runoff (1:100 not

  13. Exposure to runoff from coal-tar-sealed pavement induces genotoxicity and impairment of DNA repair capacity in the RTL-W1 fish liver cell line

    Energy Technology Data Exchange (ETDEWEB)

    Kienzler, Aude, E-mail: aude.kienzler@entpe.fr [Université de Lyon, UMR LEHNA 5023, USC INRA, ENTPE, rue Maurice Audin, Vaulx-en-Velin F-69518 (France); Mahler, Barbara J., E-mail: bjmahler@usgs.gov [U.S. Geological Survey, 1505 Ferguson Lane, Austin, TX 78754 (United States); Van Metre, Peter C., E-mail: pcvanmet@usgs.gov [U.S. Geological Survey, 1505 Ferguson Lane, Austin, TX 78754 (United States); Schweigert, Nathalie [Université de Lyon, UMR LEHNA 5023, USC INRA, ENTPE, rue Maurice Audin, Vaulx-en-Velin F-69518 (France); Devaux, Alain, E-mail: alain.devaux@entpe.fr [Université de Lyon, UMR LEHNA 5023, USC INRA, ENTPE, rue Maurice Audin, Vaulx-en-Velin F-69518 (France); Bony, Sylvie, E-mail: bony@entpe.fr [Université de Lyon, UMR LEHNA 5023, USC INRA, ENTPE, rue Maurice Audin, Vaulx-en-Velin F-69518 (France)

    2015-07-01

    Coal-tar-based (CTB) sealcoat, frequently applied to parking lots and driveways in North America, contains elevated concentrations of polycyclic aromatic hydrocarbons (PAHs) and related compounds. The RTL-W1 fish liver cell line was used to investigate two endpoints (genotoxicity and DNA-repair-capacity impairment) associated with exposure to runoff from asphalt pavement with CTB sealcoat or with an asphalt-based sealcoat hypothesized to contain about 7% CTB sealcoat (AS-blend). Genotoxic potential was assessed by the Formamido pyrimidine glycosylase (Fpg)-modified comet assay for 1:10 and 1:100 dilutions of runoff samples collected from 5 h to 36 d following sealcoat application. DNA-repair capacity was assessed by the base excision repair comet assay for 1:10 dilution of samples collected 26 h and 36 d following application. Both assays were run with and without co-exposure to ultraviolet-A radiation (UVA). With co-exposure to UVA, genotoxic effects were significant for both dilutions of CTB runoff for three of four sample times, and for some samples of AS-blend runoff. Base excision repair was significantly impaired for CTB runoff both with and without UVA exposure, and for AS-blend runoff only in the absence of UVA. This study is the first to investigate the effects of exposure to the complex mixture of chemicals in coal tar on DNA repair capacity. The results indicate that co-exposure to runoff from CT-sealcoated pavement and UVA as much as a month after sealcoat application has the potential to cause genotoxicity and impair DNA repair capacity. - Highlights: • Co-exposure to runoff from coal-tar-sealcoated pavement and UVA caused DNA damage. • Significant genotoxicity occurred with a 1:100 dilution of runoff. • Runoff collected up to 36 d following coal-tar-sealcoat application was genotoxic. • Exposure to runoff from sealed pavement impaired an important DNA repair pathway. • Repair capacity was impaired with a 1:10 dilution of runoff (1:100 not

  14. Nonlinear Power-Level Control of the MHTGR Only with the Feedback Loop of Helium Temperature

    Directory of Open Access Journals (Sweden)

    Zhe Dong

    2013-02-01

    Full Text Available Power-level control is a crucial technique for the safe, stable and efficient operation of modular high temperature gas-cooled nuclear reactors (MHTGRs, which have strong inherent safety features and high outlet temperatures. The current power-level controllers of the MHTGRs need measurements of both the nuclear power and the helium temperature, which cannot provide satisfactory control performance and can even induce large oscillations when the neutron sensors are in error. In order to improve the fault tolerance of the control system, it is important to develop a power-level control strategy that only requires the helium temperature. The basis for developing this kind of control law is to give a state-observer of the MHTGR a relationship that only needs the measurement of helium temperature. With this in mind, a novel nonlinear state observer which only needs the measurement of helium temperature is proposed. This observer is globally convergent if there is no disturbance, and has the L2 disturbance attenuation performance if the disturbance is nonzero. The separation principle of this observer is also proven, which denotes that this observer can recover the performance of both globally asymptotic stabilizers and L2 disturbance attenuators. Then, a new dynamic output feedback power-level control strategy is established, which is composed of this observer and the well-built static state-feedback power-level control based upon iterative dissipation assignment (IDA-PLC. Finally, numerical simulation results show the high performance and feasibility of this newly-built dynamic output feedback power-level controller.

  15. US power plant sites at risk of future sea-level rise

    International Nuclear Information System (INIS)

    Bierkandt, R; Levermann, A; Auffhammer, M

    2015-01-01

    Unmitigated greenhouse gas emissions may increase global mean sea-level by about 1 meter during this century. Such elevation of the mean sea-level enhances the risk of flooding of coastal areas. We compute the power capacity that is currently out-of-reach of a 100-year coastal flooding but will be exposed to such a flood by the end of the century for different US states, if no adaptation measures are taken. The additional exposed capacity varies strongly among states. For Delaware it is 80% of the mean generated power load. For New York this number is 63% and for Florida 43%. The capacity that needs additional protection compared to today increases by more than 250% for Texas, 90% for Florida and 70% for New York. Current development in power plant building points towards a reduced future exposure to sea-level rise: proposed and planned power plants are less exposed than those which are currently operating. However, power plants that have been retired or canceled were less exposed than those operating at present. If sea-level rise is properly accounted for in future planning, an adaptation to sea-level rise may be costly but possible. (letter)

  16. Thermal analysis of multi-MW two-level wind power converter

    DEFF Research Database (Denmark)

    Zhou, Dao; Blaabjerg, Frede; Mogens, Lau

    2012-01-01

    In this paper, the multi-MW wind turbine of partial-scale and full-scale two-level power converter with DFIG and direct-drive PMSG are designed and compared in terms of their thermal performance. Simulations of different configurations regarding loss distribution and junction temperature...... in the power device in the whole range of wind speed are presented and analyzed. It is concluded that in both partial-scale and full-scale power converter the most thermal stressed power device in the generator-side converter will have higher mean junction temperature and larger junction temperature...... fluctuation compared to grid-side converter at the rated wind speed. Moreover, the thermal performance of the generator-side converter in the partial-scale power converter becomes crucial around the synchronous operating point and should be considered carefully....

  17. Behavioral System Level Power Consumption Modeling of Mobile Video Streaming applications

    OpenAIRE

    Benmoussa , Yahia; Boukhobza , Jalil; Hadjadj-Aoul , Yassine; Lagadec , Loïc; Benazzouz , Djamel

    2012-01-01

    National audience; Nowadays, the use of mobile applications and terminals faces fundamental challenges related to energy constraint. This is due to the limited battery lifetime as compared to the increasing hardware evolution. Video streaming is one of the most energy consuming applications in a mobile system because of its intensive use of bandwidth, memory and processing power. In this work, we aim to propose a methodology for building and validating a high level global power consumption mo...

  18. Disentangling Bargaining Power from Individual and Household Level to Institutions: Evidence on Women’s Position in Ethiopia

    NARCIS (Netherlands)

    I.P. van Staveren (Irene); R. Mabsout (Ramzi)

    2010-01-01

    textabstractSUMMARY Women's bargaining power is generally analyzed only with individual level and household level variables. We add a third level, namely institutional bargaining power. We define this as bargaining power which one party freely derives from unequal social norms. In the bargaining

  19. Design and operation of 140 GHz gyrotron oscillators for power levels up to 1 MW CW

    Energy Technology Data Exchange (ETDEWEB)

    Jory, H.; Bier, R.; Craig, L.J.; Felch, K.; Ives, L.; Lopez, N.; Spang, S.

    1986-12-01

    Varian has designed and tested 140 GHz gyrotron oscillators that have generated output powers of 100 kW CW and 200 kW for 1 ms pulses. Upcoming tubes will be designed to operate at power levels of 200 kW CW and ultimately up to 1 MW CW. The important design considerations which are addressed in the higher power tubes include the design of the electron gun, interaction circuit, and output window. These issues will be discussed and the results of the earlier 140 GHz gyrotron work at Varian will be summarized.

  20. Design and operation of 140 GHz gyrotron oscillators for power levels up to 1 MW CW

    International Nuclear Information System (INIS)

    Jory, H.; Bier, R.; Craig, L.J.; Felch, K.; Ives, L.; Lopez, N.; Spang, S.

    1986-12-01

    Varian has designed and tested 140 GHz gyrotron oscillators that have generated output powers of 100 kW CW and 200 kW for 1 ms pulses. Upcoming tubes will be designed to operate at power levels of 200 kW CW and ultimately up to 1 MW CW. The important design considerations which are addressed in the higher power tubes include the design of the electron gun, interaction circuit, and output window. These issues will be discussed and the results of the earlier 140 GHz gyrotron work at Varian will be summarized

  1. Level-one modules library for DSNP: Dynamic Simulator for Nuclear Power-plants

    International Nuclear Information System (INIS)

    Saphier, D.

    1978-09-01

    The Dynamic Simulator for Nuclear Power-plants (DSNP) is a system of programs and data sets by which a nuclear power plant or part thereof can be simulated at different levels of sophistication. The acronym DSNP is used interchangeably for the DSNP language, for the DSNP precompiler, for the DSNP libraries, and for the DSNP document generator. The DSNP language is a set of simple block oriented statements, which together with the appropriate data, comprise a simulation of a nuclear power plant. The majority of the DSNP statements will result in the inclusion of a simulated physical module into the program. FORTRAN statements can be inserted with no restrictions among DSNP statements

  2. Soil radioactivity levels and radiation hazard assessment around a Thermal Power Plant

    International Nuclear Information System (INIS)

    Kumar, Mukesh; Kumar, Pankaj; Sharma, Somdutt; Agrawal, Anshu; Kumar, Rajesh; Prajith, Rama; Sahoo, B.K.

    2016-01-01

    Coal based thermal power plants further enhance the level of radioactivity in the environment, as burning of coal produces fly ash that can be released into the environment containing traces of 238 U, 232 Th and their decay products. Therefore, coal fired power plants are one of the major contributor towards the Technologically Enhanced Natural Radiation (TENR). Keeping this in view, a study of natural radioactivity in the soil of twenty five villages within 5 km radius around the Harduaganj Thermal Power Plant, Aligarh, UP, India is going on under a BRNS major project, to know the radiological implications on general population living around this plant

  3. Battery Recharging Issue for a Two-Power-Level Flywheel System

    Directory of Open Access Journals (Sweden)

    Janaína Gonçalves de Oliveira

    2010-01-01

    Full Text Available A novel battery recharging system for an all-electric driveline comprising a flywheel with a permanent magnet double wound synchronous machine (motor/generator is presented. The double winding enables two voltage levels and two different power levels. This topology supersedes other all-electric drivelines. The battery operates in a low-power regime supplying the average power whereas the flywheel delivers and absorbs power peaks, which are up to a higher order of magnitude. The topology presents new challenges for the power conversion system, which is the focus of this investigation. The main challenge is the control of the power flow to the battery when the vehicle is parked despite the decay of the flywheel machine voltage; which is dependent on its charge state, that is, rotational speed. The design and simulation of an unidirectional DC/DC buck/boost converter for a variable rotational speed flywheel is presented. Conventional power electronic converters are used in a new application, which can maintain a constant current or voltage on the battery side. Successful PI current control has been implemented and simulated, together with the complete closed loop system.

  4. Three-level grid-connected photovoltaic inverter with maximum power point tracking

    International Nuclear Information System (INIS)

    Tsang, K.M.; Chan, W.L.

    2013-01-01

    Highlight: ► This paper reports a novel 3-level grid connected photovoltaic inverter. ► The inverter features maximum power point tracking and grid current shaping. ► The inverter can be acted as an active filter and a renewable power source. - Abstract: This paper presents a systematic way of designing control scheme for a grid-connected photovoltaic (PV) inverter featuring maximum power point tracking (MPPT) and grid current shaping. Unlike conventional design, only four power switches are required to achieve three output levels and it is not necessary to use any phase-locked-loop circuitry. For the proposed scheme, a simple integral controller has been designed for the tracking of the maximum power point of a PV array based on an improved extremum seeking control method. For the grid-connected inverter, a current loop controller and a voltage loop controller have been designed. The current loop controller is designed to shape the inverter output current while the voltage loop controller can maintain the capacitor voltage at a certain level and provide a reference inverter output current for the PV inverter without affecting the maximum power point of the PV array. Experimental results are included to demonstrate the effectiveness of the tracking and control scheme.

  5. System-level power optimization for real-time distributed embedded systems

    Science.gov (United States)

    Luo, Jiong

    Power optimization is one of the crucial design considerations for modern electronic systems. In this thesis, we present several system-level power optimization techniques for real-time distributed embedded systems, based on dynamic voltage scaling, dynamic power management, and management of peak power and variance of the power profile. Dynamic voltage scaling has been widely acknowledged as an important and powerful technique to trade off dynamic power consumption and delay. Efficient dynamic voltage scaling requires effective variable-voltage scheduling mechanisms that can adjust voltages and clock frequencies adaptively based on workloads and timing constraints. For this purpose, we propose static variable-voltage scheduling algorithms utilizing criticalpath driven timing analysis for the case when tasks are assumed to have uniform switching activities, as well as energy-gradient driven slack allocation for a more general scenario. The proposed techniques can achieve closeto-optimal power savings with very low computational complexity, without violating any real-time constraints. We also present algorithms for power-efficient joint scheduling of multi-rate periodic task graphs along with soft aperiodic tasks. The power issue is addressed through both dynamic voltage scaling and power management. Periodic task graphs are scheduled statically. Flexibility is introduced into the static schedule to allow the on-line scheduler to make local changes to PE schedules through resource reclaiming and slack stealing, without interfering with the validity of the global schedule. We provide a unified framework in which the response times of aperiodic tasks and power consumption are dynamically optimized simultaneously. Interconnection network fabrics point to a new generation of power-efficient and scalable interconnection architectures for distributed embedded systems. As the system bandwidth continues to increase, interconnection networks become power/energy limited as

  6. System-Level Value of a Gas Engine Power Plant in Electricity and Reserve Production

    Directory of Open Access Journals (Sweden)

    Antti Alahäivälä

    2017-07-01

    Full Text Available Power systems require a certain amount of flexibility to meet varying demand and to be able to cope with unexpected events, and this requirement is expected to increase with the emergence of variable power generation. In this paper, we focus on gas engine power plant technology and the beneficial influence its flexible operation can have on a power system. The study introduces the concept of a combined-cycle gas engine power plant (CCGE, which comprises a combination of several gas-fired combustion engines and a steam turbine. The operation of CCGE is then comprehensively analyzed in electricity and reserve production in the South African power system and compared with combined-cycle gas turbine (CCGT technology. Even though CCGE is a form of technology that has already been commercialized, it is rarely considered as a source of flexibility in the academic research. That is the notion providing the motivation for this study. Our core contribution is to show that the flexibility of CCGE can be valuable in power systems. The methodology is based on the unit-level model of the studied system and the solving of a day-ahead unit commitment problem for each day of the simulated 11-year period. The simulation studies reveal how a CCGE is able to offer system flexibility to follow hourly load variations and capacity to provide reserve power effectively.

  7. Energy Use and Power Levels in New Monitors and Personal Computers; TOPICAL

    International Nuclear Information System (INIS)

    Roberson, Judy A.; Homan, Gregory K.; Mahajan, Akshay; Nordman, Bruce; Webber, Carrie A.; Brown, Richard E.; McWhinney, Marla; Koomey, Jonathan G.

    2002-01-01

    Our research was conducted in support of the EPA ENERGY STAR Office Equipment program, whose goal is to reduce the amount of electricity consumed by office equipment in the U.S. The most energy-efficient models in each office equipment category are eligible for the ENERGY STAR label, which consumers can use to identify and select efficient products. As the efficiency of each category improves over time, the ENERGY STAR criteria need to be revised accordingly. The purpose of this study was to provide reliable data on the energy consumption of the newest personal computers and monitors that the EPA can use to evaluate revisions to current ENERGY STAR criteria as well as to improve the accuracy of ENERGY STAR program savings estimates. We report the results of measuring the power consumption and power management capabilities of a sample of new monitors and computers. These results will be used to improve estimates of program energy savings and carbon emission reductions, and to inform rev isions of the ENERGY STAR criteria for these products. Our sample consists of 35 monitors and 26 computers manufactured between July 2000 and October 2001; it includes cathode ray tube (CRT) and liquid crystal display (LCD) monitors, Macintosh and Intel-architecture computers, desktop and laptop computers, and integrated computer systems, in which power consumption of the computer and monitor cannot be measured separately. For each machine we measured power consumption when off, on, and in each low-power level. We identify trends in and opportunities to reduce power consumption in new personal computers and monitors. Our results include a trend among monitor manufacturers to provide a single very low low-power level, well below the current ENERGY STAR criteria for sleep power consumption. These very low sleep power results mean that energy consumed when monitors are off or in active use has become more important in terms of contribution to the overall unit energy consumption (UEC

  8. Admissibility of building cost subsidy in the power grid above the low voltage level

    International Nuclear Information System (INIS)

    Foerster, Sven

    2015-01-01

    Electricity networks are essential to the provision of electrical power to businesses and individuals. In particular for manufacturing businesses a connection to the grid above the low-voltage level is often useful. Network operators demand a subsidy for the new connection and for the change to a higher network level under the auspices of construction cost. The power network market above the low-voltage level is a natural monopoly. This leaves consumers looking for a connection to the power grid with no possibility to select among different network operators. Construction cost subsidies are not regulated by law above the low voltage level. The lack of legal regulation and the natural monopoly above the low-voltage level affect the balance of power between network operators and system users. The lawfulness of the construction cost subsidies, the prerequisites for their demand and a review of the calculation models (Leistungspreismodell, 2-Ebenen-Modell) as well as a proposal for a reform of this system form the subject of this work.

  9. A novel synthetic test system for thyristor level in the converter valve of HVDC power transmission

    Directory of Open Access Journals (Sweden)

    Liu Longchen

    2016-01-01

    Full Text Available The converter valve is the core equipment in the HVDC power transmission system, a+-nd its performance has a direct effect on the reliability, stability and efficiency of the whole power system. As the basic unit of HVDC converter valve, the thyristor level needs to be test routinely in order to grasp the state of the converter valve equipment. Therefore, it is urgent to develop a novel synthetic test system for the thyristor level with thyristor control unit (TCU. However, currently there is no specific test scheme for the thyristor level of HVDC converter valve. In this paper, the synthetic test principle, content and methods for the thyristor level with TCU are presented based on the analysis of the thyristor reverse recovery characteristic and the IEC technology standard. And a transient high-voltage pulse is applied to the thyristor level during its reverse recovery period in order to test the characteristics of thyristor level. Then, the synthetic test system for the thyristor level is applied to the converter valve test of ±800 kV HVDC power transmission project, and the practical test result verifies the reasonability and validity of the proposed synthetic test system.

  10. Temporary core liquid level depression during cold-leg small-break LOCA effect of break size and power level

    International Nuclear Information System (INIS)

    Koizumi, Y.; Kumamaru, H.; Mimura, Y.; Kukita, Y.; Tasaka, K.

    1989-01-01

    Cold-leg small break LOCA experiments (0.5-10% break) were conducted at the large scale test facility (LSTF), a volumetrically-scaled (1/48) simulator of a PWR, of the ROSA-IV Program. When a break area was less than 2.5% of the scaled cold-leg flow area, the core liquid level was temporarily further depressed to the bottom elevation of the crossover leg during the loop seal clearing early in the transient only by the manometric pressure balance since no coolant remained in the upper portion of the primary system. When the break size was larger than 5%, the core liquid level was temporarily further depressed lower than the bottom elevation of the crossover leg during the loop seal clearing since coolant remained at the upper portion of the primary system; the steam generator (SG) U-tube upflow side and the SG inlet plenum, due to counter current flow limiting by updrafting steam while the coolant drained. The amount of coolant trapped there was dependent on the vapor velocity (core power); the larger the core power, the lower the minimum core liquid level. The RELAP5/MOD2 code reasonable predicted phenomena observed in the experiments. (orig./DG)

  11. Fuzzy algorithms to generate level controllers for nuclear power plant steam generators

    International Nuclear Information System (INIS)

    Moon, Byung Soo; Park, Jae Chang; Kim, Dong Hwa; Kim, Byung Koo

    1993-01-01

    In this paper, we present two sets of fuzzy algorithms for the steam generater level control; one for the high power operations where the flow error is available and the other for the low power operations where the flow error is not available. These are converted to a PID type controller for the high power case and to a quadratic function form of a controller for the low power case. These controllers are implemented on the Compact Nuclear Simulator at Korea Atomic Energy Research Institute and tested by a set of four simulation experiments for each. For both cases, the results show that the total variation of the level error and of the flow error are about 50% of those by the PI controllers with about one half of the control action. For the high power case, this is mainly due to the fact that a combination of two PD type controllers in the velocity algorithm form rather than a combination of two PI type controllers in the position algorithm form is used. For the low power case, the controller is essentially a PID type with a very small integral component where the average values for the derivative component input and for the controller output are used. (Author)

  12. Estimating the vibration level of an L-shaped beam using power flow techniques

    Science.gov (United States)

    Cuschieri, J. M.; Mccollum, M.; Rassineux, J. L.; Gilbert, T.

    1986-01-01

    The response of one component of an L-shaped beam, with point force excitation on the other component, is estimated using the power flow method. The transmitted power from the source component to the receiver component is expressed in terms of the transfer and input mobilities at the excitation point and the joint. The response is estimated both in narrow frequency bands, using the exact geometry of the beams, and as a frequency averaged response using infinite beam models. The results using this power flow technique are compared to the results obtained using finite element analysis (FEA) of the L-shaped beam for the low frequency response and to results obtained using statistical energy analysis (SEA) for the high frequencies. The agreement between the FEA results and the power flow method results at low frequencies is very good. SEA results are in terms of frequency averaged levels and these are in perfect agreement with the results obtained using the infinite beam models in the power flow method. The narrow frequency band results from the power flow method also converge to the SEA results at high frequencies. The advantage of the power flow method is that detail of the response can be retained while reducing computation time, which will allow the narrow frequency band analysis of the response to be extended to higher frequencies.

  13. Biographical learning in top-level coaching - personal styles and the power of practical sense

    DEFF Research Database (Denmark)

    Christensen, Mette Krogh

    : Biographical learning in top-level coaching - personal styles and the power of practical sense. There is a growing body of studies in sports coaching cultures, comprising research focusing on the individual learning processes and life histories of top-level coaches. Even if top-level sport has become...... explores the relation between these kinds of learning processes and the coaches’ development of practical sense of talent. I base the paper on a sociological analysis of in-depth interviews with eight Danish top-level football coaches about their pathways to expertise. Results illustrate two interwoven...... in young footballers. The results point to an important challenge in coach education and coach socialization: the construction and power of coaches’ personal “styles”....

  14. Determination of the lowest critical power levels of the Dalat Nuclear Research Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Huy, Ngo Quang [Centre for Nuclear Technique Application, Ho Chi Minh City (Viet Nam); Thong, Ha Van; Long, Vu Hai; Binh, Do Quang; Nghiem, Huynh Ton; Tuan, Nguyen Minh; Vien, Luong Ba; Vinh, Le Vinh [Nuclear Research Inst., Da Lat (Viet Nam)

    1994-10-01

    This paper presents the experimental methods for determining critical states of the Dalat Nuclear Research Reactor containing an extraneous neutron source induced by gamma ray reactions on beryllium in the reactor. The lowest critical power levels are measured at various moments after the reactor is shut down following 100 hours of its continuous operation. Th power levels vary from (0.5-1.2) x 10{sup -4} of P{sub n}, i.e. (25-60)W to (1.1-1.6) x 10{sup -5} of P{sub n}, i.e. (5.5-8)W at corresponding times of 4 days to 13 days after the reactor is shut down. However the critical power must be chosen greater than 500 W to sustain the steady criticality of the reactor for a long time. (author). 3 refs. 4 figs. 1 tab.

  15. The Evolution of Power System Planning with High Levels of Variable Renewable Generation

    Energy Technology Data Exchange (ETDEWEB)

    Katz, Jessica [National Renewable Energy Lab. (NREL), Golden, CO (United States); Milligan, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2016-09-01

    Greening the Grid provides technical assistance to energy system planners, regulators, and grid operators to overcome challenges associated with integrating variable renewable energy into the grid. This document, part of the Greening the Grid introduces the evolution of power system planning with high levels of variable renewable generation.

  16. Dealing with Law in migration control: The Powers of Street-level bureaucrats at French Consulates

    NARCIS (Netherlands)

    Alpes, M.J.; Spire, A.

    2014-01-01

    This article examines how street-level bureaucrats within migration control use their scope for discretionary powers. On the basis of two ethnographic studies of French consulates in Yaoundé and Tunis, we argue that state agents' practices are significantly shaped by organizational constraints such

  17. Prospective Physics Teachers' Level of Understanding Energy, Power and Force Concepts

    Science.gov (United States)

    Saglam-Arslan, Aysegul; Kurnaz, Mehmet Altan

    2009-01-01

    The aim of this study is to determine prospective physics teachers' level of understanding of the concepts of energy and the related concepts of force and power. The study was carried out with the participation of 56 physics education department students at a university in Karadeniz region. All participants had previously taken an introductory…

  18. A high-level power model for MPSoC on FPGA

    NARCIS (Netherlands)

    Piscitelli, R.; Pimentel, A.D.

    2012-01-01

    This paper presents a framework for high-level power estimation of multiprocessor systems-on-chip (MPSoC) architectures on FPGA. The technique is based on abstract execution profiles, called event signatures. As a result, it is capable of achieving good evaluation performance, thereby making the

  19. Model for the techno-economic analysis of common work of wind power and CCGT power plant to offer constant level of power in the electricity market

    Science.gov (United States)

    Tomsic, Z.; Rajsl, I.; Filipovic, M.

    2017-11-01

    Wind power varies over time, mainly under the influence of meteorological fluctuations. The variations occur on all time scales. Understanding these variations and their predictability is of key importance for the integration and optimal utilization of wind in the power system. There are two major attributes of variable generation that notably impact the participation on power exchanges: Variability (the output of variable generation changes and resulting in fluctuations in the plant output on all time scales) and Uncertainty (the magnitude and timing of variable generation output is less predictable, wind power output has low levels of predictability). Because of these variability and uncertainty wind plants cannot participate to electricity market, especially to power exchanges. For this purpose, the paper presents techno-economic analysis of work of wind plants together with combined cycle gas turbine (CCGT) plant as support for offering continues power to electricity market. A model of wind farms and CCGT plant was developed in program PLEXOS based on real hourly input data and all characteristics of CCGT with especial analysis of techno-economic characteristics of different types of starts and stops of the plant. The Model analyzes the followings: costs of different start-stop characteristics (hot, warm, cold start-ups and shutdowns) and part load performance of CCGT. Besides the costs, the technical restrictions were considered such as start-up time depending on outage duration, minimum operation time, and minimum load or peaking capability. For calculation purposes, the following parameters are necessary to know in order to be able to economically evaluate changes in the start-up process: ramp up and down rate, time of start time reduction, fuel mass flow during start, electricity production during start, variable cost of start-up process, cost and charges for life time consumption for each start and start type, remuneration during start up time regarding

  20. Evaluation of safety issues on newly regulated nuclear power plant by tsunami-level 1 PRA

    International Nuclear Information System (INIS)

    Tsuji, Yutaro; Miwa, Shuichiro; Mori, Michitsugu

    2014-01-01

    The tsunami caused by the Great East Japan Earthquake triggered severe accidents involving the units 1 to 4 at the Fukushima Dai-ichi nuclear power station (NPS). In order to re-operate existing nuclear power plants it should be necessary to reduce the core damage frequency on risk by tsunami. In this work, effects of the off-site power supply installation on resuming operation of nuclear power plants were investigated by utilizing the Tsunami-Level 1 Probability Risk Assessment (PRA). Unit 2 of the Onagawa nuclear power station, which resembled units 2 and 3 of Fukushima Dai-ichi, was selected for PRA. First, event-tree was created for the units of the Onagawa nuclear power station with the safety systems such as Emergency Core Cooling System (ECCS), investigating the plant situation at the time of the earthquake and tsunami occurrences. It was assumed that the magnitude of the tsunami was equivalent to the Great East Japan Earthquake. The accident-analytical progression-time was 36 hours, determined from the core-damage occurrence of the unit 3 of Fukushima Dai-ichi nuclear power station. Failure probabilities were calculated by the fault tree, which was created from the elements listed in the event tree. For the calculation, failure rates reported by the NUCIA (NUClear Information Archives) were primarily utilized. Then, obtained failure probabilities were embedded to the event tree. Core damage probabilities were evaluated by calculating success and failure rates for each accidental progression and scenarios. Restoration of the failed equipment and machineries was not considered in the analysis. Installation of the power supply vehicles at the nuclear power plant site reduced the core damage probability from 2.58×10 -6 to 8.56×10 -7 . However, continued addition of the power supply vehicles could not lower the core damage probability further more. In the case of Unit 2 of Onagawa nuclear power station, there could be a limit to lower the core damage

  1. System-Level Power Consumption Analysis of the Wearable Asthmatic Wheeze Quantification

    Directory of Open Access Journals (Sweden)

    Dinko Oletic

    2018-01-01

    Full Text Available Long-term quantification of asthmatic wheezing envisions an m-Health sensor system consisting of a smartphone and a body-worn wireless acoustic sensor. As both devices are power constrained, the main criterion guiding the system design comes down to minimization of power consumption, while retaining sufficient respiratory sound classification accuracy (i.e., wheeze detection. Crucial for assessment of the system-level power consumption is the understanding of trade-off between power cost of computationally intensive local processing and communication. Therefore, we analyze power requirements of signal acquisition, processing, and communication in three typical operating scenarios: (1 streaming of uncompressed respiratory signal to a smartphone for classification, (2 signal streaming utilizing compressive sensing (CS for reduction of data rate, and (3 respiratory sound classification onboard the wearable sensor. Study shows that the third scenario featuring the lowest communication cost enables the lowest total sensor system power consumption ranging from 328 to 428 μW. In such scenario, 32-bit ARM Cortex M3/M4 cores typically embedded within Bluetooth 4 SoC modules feature the optimal trade-off between onboard classification performance and consumption. On the other hand, study confirms that CS enables the most power-efficient design of the wearable sensor (216 to 357 μW in the compressed signal streaming, the second scenario. In such case, a single low-power ARM Cortex-A53 core is sufficient for simultaneous real-time CS reconstruction and classification on the smartphone, while keeping the total system power within budget for uncompressed streaming.

  2. Evaluation of the FIR Example using Xilinx Vivado High-Level Synthesis Compiler

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Zheming [Argonne National Lab. (ANL), Argonne, IL (United States); Finkel, Hal [Argonne National Lab. (ANL), Argonne, IL (United States); Yoshii, Kazutomo [Argonne National Lab. (ANL), Argonne, IL (United States); Cappello, Franck [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-07-28

    Compared to central processing units (CPUs) and graphics processing units (GPUs), field programmable gate arrays (FPGAs) have major advantages in reconfigurability and performance achieved per watt. This development flow has been augmented with high-level synthesis (HLS) flow that can convert programs written in a high-level programming language to Hardware Description Language (HDL). Using high-level programming languages such as C, C++, and OpenCL for FPGA-based development could allow software developers, who have little FPGA knowledge, to take advantage of the FPGA-based application acceleration. This improves developer productivity and makes the FPGA-based acceleration accessible to hardware and software developers. Xilinx Vivado HLS compiler is a high-level synthesis tool that enables C, C++ and System C specification to be directly targeted into Xilinx FPGAs without the need to create RTL manually. The white paper [1] published recently by Xilinx uses a finite impulse response (FIR) example to demonstrate the variable-precision features in the Vivado HLS compiler and the resource and power benefits of converting floating point to fixed point for a design. To get a better understanding of variable-precision features in terms of resource usage and performance, this report presents the experimental results of evaluating the FIR example using Vivado HLS 2017.1 and a Kintex Ultrascale FPGA. In addition, we evaluated the half-precision floating-point data type against the double-precision and single-precision data type and present the detailed results.

  3. Natural radioactivity level in coal and ash collected from Baoji coal-fired power plant

    International Nuclear Information System (INIS)

    Jia Xiaodan; Lu Xinwei

    2006-01-01

    Specific activities of natural radionuclides 226 Ra, 232 Th and 40 K were assessed in coal (3 samples), fly ash (17 samples) and bottom ash (6 samples) collected from Baoji coal-fired power plant. This paper analyzed the characteristics of 226 Ra, 232 Th and 40 K contents in bottom ash and fly ash, and studied the concentration factors of these radionuclides in ash in relation to those in coal. The level of natural radionuclides 226 Ra, 232 Th and 40 K of coal collected from Baoji coal-fired power plant are in the range of radionuclides contents of Chinese coal. The natural radioactivity level of fly ash collected from Baoji coal-fired power plant is close to Beijing and Shanghai coal-fired power plants. The paper farther assessed the possibility of fly ash of Baoji coal-fired power plant used as building materials according to the state standard. The results show that there are 29% samples exceeding the state limit when fly ash used as building materials. So the usage of fly ash in building material should be controlled. (authors)

  4. Survey of ambient electromagnetic and radio-frequency interference levels in nuclear power plants

    International Nuclear Information System (INIS)

    Kercel, S.W.; Moore, M.R.; Blakeman, E.D.; Ewing, P.D.; Wood, R.T.

    1996-11-01

    This document reports the results of a survey of ambient electromagnetic conditions in representative nuclear power plants. The U.S. Nuclear Regulatory Commission (NRC) Office of Nuclear Regulatory Research engaged the Oak Ridge National Laboratory (ORNL) to perform these measurements to characterize the electromagnetic interference (EMI) and radio-frequency interference (RFI) levels that can be expected in nuclear power plant environments. This survey is the first of its kind, being based on long-term unattended observations. The data presented in this report were measured at eight different nuclear units and required 14 months to collect. A representative sampling of power plant conditions (reactor type, operating mode, site location) monitored over extended observation periods (up to 5 weeks) were selected to more completely determine the characteristic electromagnetic environment for nuclear power plants. Radiated electric fields were measured over the frequency range of 5 MHz to 8 GHz. Radiated magnetic fields and conducted EMI events were measured over the frequency range of 305 Hz to 5 MHz. Highest strength observations of the electromagnetic ambient environment across all measurement conditions at each site provide frequency-dependent profiles for EMI/RFI levels in nuclear power plants

  5. Studies of power exhaust and divertor design for a 1.5 GW-level fusion power DEMO

    Science.gov (United States)

    Asakura, N.; Hoshino, K.; Suzuki, S.; Tokunaga, S.; Someya, Y.; Utoh, H.; Kudo, H.; Sakamoto, Y.; Hiwatari, R.; Tobita, K.; Shimizu, K.; Ezato, K.; Seki, Y.; Ohno, N.; Ueda, Y.; Joint Special TeamDEMO Design

    2017-12-01

    Power exhaust to the divertor and the conceptual design have been investigated for a steady-state DEMO in Japan with 1.5 GW-level fusion power and the major radius of 8.5 m, where the plasma parameters were revised appropriate for the impurity seeding scenario. A system code survey for the Ar impurity seeding suggested the volume-averaged density, impurity concentration and exhaust power from the main plasma of {{P}sep ~ }   =  205-285 MW. The divertor plasma simulation (SONIC) was performed in the divertor leg length of 1.6 m with the fixed exhaust power to the edge of {{P}out}   =  250 MW and the total radiation fraction at the edge, SOL and divertor ({{P}rad}/{{P}out}   =  0.8), as a first step to investigate appropriate design of the divertor size and geometry. At the outer target, partial detachment was produced near the strike-point, and the peak heat load ({{q}target} ) at the attached region was reduced to ~5 MW m-2 with appropriate fuel and impurity puff rates. At the inner divertor target, full detachment of ion flux was produced and the peak {{q}target} was less than 10 MW m-2 mostly due to the surface-recombination. These results showed a power exhaust scenario and the divertor design concept. An integrated design of the water-cooling heat sink for the long leg divertor was proposed. Cu-ally (CuCrZr) cooling pipe was applicable as the heat sink to handle the high heat flux near the strike-point, where displacements per atom rate was estimated to be 0.5-1.5 per year by neutronics calculation. An arrangement of the coolant rooting for Cu-alloy and Reduced Activation Ferritic Martensitic (RAFM) steel (F82H) pipes in a divertor cassette was investigated, and the heat transport analysis of the W-monoblock and Cu-alloy pipe under the peak {{q}target} of 10 MWm-2 and nuclear heating was performed. The maximum temperatures on the W-surface and Cu-alloy pipe were 1021 and 331 °C. Heat flux of 16 MW m-2 was distributed in the major part

  6. Maximum power point tracking techniques for wind energy systems using three levels boost converter

    Science.gov (United States)

    Tran, Cuong Hung; Nollet, Frédéric; Essounbouli, Najib; Hamzaoui, Abdelaziz

    2018-05-01

    This paper presents modeling and simulation of three level Boost DC-DC converter in Wind Energy Conversion System (WECS). Three-level Boost converter has significant advantage compared to conventional Boost. A maximum power point tracking (MPPT) method for a variable speed wind turbine using permanent magnet synchronous generator (PMSG) is also presented. Simulation of three-level Boost converter topology with Perturb and Observe algorithm and Fuzzy Logic Control is implemented in MATLAB/SIMULINK. Results of this simulation show that the system with MPPT using fuzzy logic controller has better performance to the Perturb and Observe algorithm: fast response under changing conditions and small oscillation.

  7. Computer-based control of nuclear power information systems at international level

    International Nuclear Information System (INIS)

    Boniface, Ekechukwu; Okonkwo, Obi

    2011-01-01

    In most highly industrialized countries of the world information plays major role in anti-nuclear campaign. Information and discussions on nuclear power need critical and objective analysis before the structured information presentation to the public to avoid bias anti-nuclear information on one side and neglect of great risk in nuclear power. This research is developing a computer-based information system for the control of nuclear power at international level. The system is to provide easy and fast information highways for the followings: (1) Low Regulatory dose and activity limit as level of high danger for individuals and public. (2) Provision of relevant technical or scientific education among the information carriers in the nuclear power countries. The research is on fact oriented investigation about radioactivity. It also deals with fact oriented education about nuclear accidents and safety. A standard procedure for dissemination of latest findings using technical and scientific experts in nuclear technology is developed. The information highway clearly analyzes the factual information about radiation risk and nuclear energy. Radiation cannot be removed from our environment. The necessity of radiation utilizations defines nuclear energy as two-edge sword. It is therefore, possible to use computer-based information system in projecting and dissemination of expert knowledge about nuclear technology positively and also to use it in directing the public on the safety and control of the nuclear energy. The computer-based information highway for nuclear energy technology is to assist in scientific research and technological development at international level. (author)

  8. Neural Network with Local Memory for Nuclear Reactor Power Level Control

    International Nuclear Information System (INIS)

    Uluyol, Oender; Ragheb, Magdi; Tsoukalas, Lefteri

    2001-01-01

    A methodology is introduced for a neural network with local memory called a multilayered local output gamma feedback (LOGF) neural network within the paradigm of locally-recurrent globally-feedforward neural networks. It appears to be well-suited for the identification, prediction, and control tasks in highly dynamic systems; it allows for the presentation of different timescales through incorporation of a gamma memory. A learning algorithm based on the backpropagation-through-time approach is derived. The spatial and temporal weights of the network are iteratively optimized for a given problem using the derived learning algorithm. As a demonstration of the methodology, it is applied to the task of power level control of a nuclear reactor at different fuel cycle conditions. The results demonstrate that the LOGF neural network controller outperforms the classical as well as the state feedback-assisted classical controllers for reactor power level control by showing a better tracking of the demand power, improving the fuel and exit temperature responses, and by performing robustly in different fuel cycle and power level conditions

  9. A Security Level Classification Method for Power Systems under N-1 Contingency

    Directory of Open Access Journals (Sweden)

    Zhigang Lu

    2017-12-01

    Full Text Available Security assessment is crucial for the reliable and secure operation of power systems. This paper proposes a security level classification (SLC method to analyze the security level of power systems both qualitatively and quantitatively. In this SLC method, security levels are graded according to a comprehensive safety index (CSI, which is defined by integrating the system margin index (SMI and load entropy. The SMI depends on the operating load and the total supply capacity (TSC under N-1 contingency, and the load entropy reflects the heterogeneity of load distribution calculated from entropy theory. In order to calculate the TSC under N-1 contingency considering both of the computational accuracy and speed, the TSC is converted into an extended conic quadratic programming (ECQP model. In addition, the load boundary vector (LBV model is established to obtain the capacity limit of each load bus, and thus detect potential risks of power systems. Finally, two modified practical power systems and the IEEE 118-bus test system are studied to validate the feasibility of the proposed SLC method.

  10. PRELIMINARY OBSERVATIONS ON THE DELEGATION OF POWERS TO NATIONAL AND EUROPEAN UNION LEVEL

    Directory of Open Access Journals (Sweden)

    Silviu Alexandru Lăzărescu Simion

    2012-11-01

    Full Text Available In the context of Romania's accession to the European Union, have created the conditions to issue a new category of delegation of powers at the national level, used in the management of EU funds. Thus, delegation under delegation agreements concluded between ministries function with role management authorities and legal entities subordinated, coordination or subordination or coordination outside a hierarchy is a concrete way to exercise the powers conferred by the provisions Romania Community and pursue assimilated by delegating temporary administrative office.

  11. Design of power converter in DFIG wind turbine with enhanced system-level reliability

    DEFF Research Database (Denmark)

    Zhou, Dao; Zhang, Guanguan; Blaabjerg, Frede

    2017-01-01

    With the increasing penetration of wind power, reliable and cost-effective wind energy production are of more and more importance. As one of the promising configurations, the doubly-fed induction generator based partial-scale wind power converter is still dominating in the existing wind farms...... margin. It can be seen that the B1 lifetime of the grid-side converter and the rotor-side converter deviates a lot by considering the electrical stresses, while they become more balanced by using an optimized reliable design. The system-level lifetime significantly increases with an appropriate design...

  12. Comparative study of the base activity levels of the Spanish continental nuclear power stations

    International Nuclear Information System (INIS)

    Gregorides de los Santos y Perez-Minguez, A.M.

    1980-01-01

    In this work the pre-operational activity levels of the sites of some Spanish nuclear power stations are discussed. These power stations are located near the Tagus and Ebro river basins. A report of the communities investigated is made. The total alpha and beta activity as well as the long half life activity has been researched there. The importance of this question is obvious for it gives a regional average of the base activity in the basins of these two big Spanish rivers [fr

  13. Photovoltaic Shading Testbed for Module-Level Power Electronics: 2016 Performance Data Update

    Energy Technology Data Exchange (ETDEWEB)

    Deline, Chris [National Renewable Energy Lab. (NREL), Golden, CO (United States); Meydbray, Jenya [PV Evolution Labs (PVEL), Davis, CA (United States); Donovan, Matt [PV Evolution Labs (PVEL), Davis, CA (United States)

    2016-09-01

    The 2012 NREL report 'Photovoltaic Shading Testbed for Module-Level Power Electronics' provides a standard methodology for estimating the performance benefit of distributed power electronics under partial shading conditions. Since the release of the report, experiments have been conducted for a number of products and for different system configurations. Drawing from these experiences, updates to the test and analysis methods are recommended. Proposed changes in data processing have the benefit of reducing the sensitivity to measurement errors and weather variability, as well as bringing the updated performance score in line with measured and simulated values of the shade recovery benefit of distributed PV power electronics. Also, due to the emergence of new technologies including sub-module embedded power electronics, the shading method has been extended to include power electronics that operate at a finer granularity than the module level. An update to the method is proposed to account for these emerging technologies that respond to shading differently than module-level devices. The partial shading test remains a repeatable test procedure that attempts to simulate shading situations as would be experienced by typical residential or commercial rooftop photovoltaic (PV) systems. Performance data for multiple products tested using this method are discussed, based on equipment from Enphase, Solar Edge, Maxim Integrated and SMA. In general, the annual recovery of shading losses from the module-level electronics evaluated is 25-35%, with the major difference between different trials being related to the number of parallel strings in the test installation rather than differences between the equipment tested. Appendix D data has been added in this update.

  14. Steady-State Plant Model to Predict Hydroden Levels in Power Plant Components

    Energy Technology Data Exchange (ETDEWEB)

    Glatzmaier, Greg C.; Cable, Robert; Newmarker, Marc

    2017-06-27

    The National Renewable Energy Laboratory (NREL) and Acciona Energy North America developed a full-plant steady-state computational model that estimates levels of hydrogen in parabolic trough power plant components. The model estimated dissolved hydrogen concentrations in the circulating heat transfer fluid (HTF), and corresponding partial pressures within each component. Additionally for collector field receivers, the model estimated hydrogen pressure in the receiver annuli. The model was developed to estimate long-term equilibrium hydrogen levels in power plant components, and to predict the benefit of hydrogen mitigation strategies for commercial power plants. Specifically, the model predicted reductions in hydrogen levels within the circulating HTF that result from purging hydrogen from the power plant expansion tanks at a specified target rate. Our model predicted hydrogen partial pressures from 8.3 mbar to 9.6 mbar in the power plant components when no mitigation treatment was employed at the expansion tanks. Hydrogen pressures in the receiver annuli were 8.3 to 8.4 mbar. When hydrogen partial pressure was reduced to 0.001 mbar in the expansion tanks, hydrogen pressures in the receiver annuli fell to a range of 0.001 mbar to 0.02 mbar. When hydrogen partial pressure was reduced to 0.3 mbar in the expansion tanks, hydrogen pressures in the receiver annuli fell to a range of 0.25 mbar to 0.28 mbar. Our results show that controlling hydrogen partial pressure in the expansion tanks allows us to reduce and maintain hydrogen pressures in the receiver annuli to any practical level.

  15. Effect of focused ultrasound stimulation at different ultrasonic power levels on the local field potential power spectrum

    International Nuclear Information System (INIS)

    Yuan Yi; Lu Cheng-Biao; Li Xiao-Li

    2015-01-01

    Local field potential (LFP) signals of the rat hippocampus were recorded under noninvasive focused ultrasound stimulation (FUS) with different ultrasonic powers. The LFP mean absolute power was calculated with the Welch algorithm at the delta, theta, alpha, beta, and gamma frequency bands. The experimental results demonstrate that the LFP mean absolute power at different frequency bands increases as the ultrasound power increases. (paper)

  16. Study and Analysis of a Natural Reference Frame Current Controller for a Multi-Level H-Bridge Power Converter

    DEFF Research Database (Denmark)

    Ciobotaru, Mihai; Iov, Florin; Zanchetta, P.

    2008-01-01

    will be needed in order to control the power flow and to ensure proper and secure operation of this future grid with an increased level of renewable power. These power converters must be able to provide intelligent power management as well as ancillary services. This paper presents an analysis of the natural...... reference frame controller, based on proportional-resonant (PR) technique, for a multi-level H-bridge power converter for Universal and Flexible Power Management in Future Electricity Network. The proposed method is tested in terms of harmonic content in the Point of Common Coupling (PCC), voltage...

  17. Effect of Low-Level Laser Stimulation on EEG Power in Normal Subjects with Closed Eyes

    Directory of Open Access Journals (Sweden)

    Jih-Huah Wu

    2013-01-01

    Full Text Available In a previous study, we found that the low-level laser (LLL stimulation at the palm with a frequency of 10 Hz was able to induce significant brain activation in normal subjects with opened eyes. However, the electroencephalography (EEG changes to LLL stimulation in subjects with closed eyes have not been studied. In the present study, the laser array stimulator was applied to deliver insensible laser stimulations to the palm of the tested subjects with closed eyes (the laser group. The EEG activities before, during, and after the laser stimulation were collected. The EEG amplitude powers of each EEG frequency band at 19 locations were calculated. These power data were then analyzed by SPSS software using repeated-measure ANOVAs and appropriate posthoc tests. We found a pronounced decrease in the EEG power in alpha-bandwidth during laser simulation and then less decrease in the EEG power in delta-bandwidth in normal subjects with laser stimulation. The EEG power in beta-bandwidth in the right occipital area also decreased significantly in the laser group. We suggest that LLL stimulation might be conducive to falling into sleep in patients with sleep problems.

  18. Disentangling Bargaining Power from Individual and Household Level to Institutions: Evidence on Women’s Position in Ethiopia

    OpenAIRE

    Staveren, Irene; Mabsout, Ramzi

    2010-01-01

    textabstractSUMMARY Women's bargaining power is generally analyzed only with individual level and household level variables. We add a third level, namely institutional bargaining power. We define this as bargaining power which one party freely derives from unequal social norms. In the bargaining literature there is a common paradoxical finding, namely that more access to and control over individual resources sometimes decreases rather than increases women‟s bargaining outcomes. With household...

  19. Minimizing the Levelized Cost of Energy in Single-Phase Photovoltaic Systems with an Absolute Active Power Control

    DEFF Research Database (Denmark)

    Yang, Yongheng; Koutroulis, Eftichios; Sangwongwanich, Ariya

    2015-01-01

    . An increase of the inverter lifetime and a reduction of the energy yield can alter the cost of energy, demanding an optimization of the power limitation. Therefore, aiming at minimizing the Levelized Cost of Energy (LCOE), the power limit is optimized for the AAPC strategy in this paper. The optimization...... control strategy, the Absolute Active Power Control (AAPC) can effectively solve the overloading issues by limiting the maximum possible PV power to a certain level (i.e., the power limitation), and also benefit the inverter reliability. However, its feasibility is challenged by the energy loss......, compared to the conventional PV inverter operating only in the maximum power point tracking mode. In the presented case study, the minimum of LCOE is achieved for the system when the power limit is optimized to a certain level of the designed maximum feed-in power (i.e., 3 kW). In addition, the proposed...

  20. Habit, custom, and power: a multi-level theory of population health.

    Science.gov (United States)

    Zimmerman, Frederick J

    2013-03-01

    In multi-level theory, individual behavior flows from cognitive habits, either directly through social referencing, rules of thumb, or automatic behaviors; or indirectly through the shaping of rationality itself by framing or heuristics. Although behavior does not arise from individually rational optimization, it generally appears to be rational, because the cognitive habits that guide behavior evolve toward optimality. However, power imbalances shaped by particular social, political, and economic structures can distort this evolution, leading to individual behavior that fails to maximize individual or social well-being. Replacing the dominant rational-choice paradigm with a multi-level theoretical paradigm involving habit, custom, and power will enable public health to engage in rigorous new areas of research. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Application of PSA to Assess the Safety Level of Nuclear Power Plants

    International Nuclear Information System (INIS)

    Berg, H. P.; Goertz, R.

    2000-01-01

    This paper reviews the application of PSA in German nuclear power plant regulation. From a fundamental point of view, it has to be mentioned that as stipulated in the corresponding requirements, regulatory decision making in Germany is primarily based on deterministic analyses and evaluations. Therefore, PSA is not used as a stand alone but as a supplementary basis. In this context PSA has developed a valuable tool with continuously growing importance. Level 1+ PSAs are now elaborated for all German nuclear power plants in operation, most of them are already reviewed by the competent supervisory authority and its experts. Current research activities on the federal level primarily concentrate on the further development of the methodology in the areas human factor, common cause failures, accident management measures and reduction of uncertainties in methods and data. (author)

  2. A Transformer-less Partial Power Boost Converter for PV Applications Using a Three-Level Switching Cell

    Energy Technology Data Exchange (ETDEWEB)

    Agamy, Mohammed; Harfman-Todorovic, Maja; Elasser, Ahmed; Essakiappan, Somasundaram

    2013-03-01

    Photovoltaic architectures with distributed power electronics provide many advantages in terms of energy yield as well as system level optimization. As the power level of the solar farm increases it becomes more beneficial to increase the dc collection network voltage, which requires the use of power devices with higher voltage ratings, and thus making the design of efficient, low cost, distributed power converters more challenging. In this paper a simple partial power converter topology is proposed. The topology is implemented using a three-level switching cell, which allows the use of semiconductor devices with lower voltage rating; thus improving design and performance and reducing converter cost. This makes the converters suitable for use for medium to high power applications where dc-link voltages of 600V~1kV may be needed without the need for high voltage devices. Converter operation and experimental results are presented for two partial power circuit variants using three-level switching cells.

  3. Fine-hyperfine splittings of quarkonium levels in an effective power-law potential

    Energy Technology Data Exchange (ETDEWEB)

    Barik, N; Jena, S N [Utkal Univ., Bhubaneswar (India). Dept. of Physics

    1980-12-01

    We have shown that an effective non-coulombic power-law potential generating spin dependence through scalar and vector exchanges in almost equal proportions along with a very small or zero quark anomalous moment can describe very satisfactorily the up-to-date data on the fine-hyperfine levels and the leptonic width ratios of the vector mesons in the cc and bb families in a flavour independent manner.

  4. Fine-hyperfine splittings of quarkonium levels in an effective power-law potential

    International Nuclear Information System (INIS)

    Barik, N.; Jena, S.N.

    1980-01-01

    We have shown that an effective non-coulombic power-law potential generating spin dependence through scalar and vector exchanges in almost equal proportions along with a very small or zero quark anomalous moment can describe very satisfactorily the up-to-date data on the fine-hyperfine levels and the leptonic width ratios of the vector mesons in the cc and bb families in a flavour independent manner. (orig.)

  5. POPCYCLE: a computer code for calculating nuclear and fossil plant levelized life-cycle power costs

    International Nuclear Information System (INIS)

    Hardie, R.W.

    1982-02-01

    POPCYCLE, a computer code designed to calculate levelized life-cycle power costs for nuclear and fossil electrical generating plants is described. Included are (1) derivations of the equations and a discussion of the methodology used by POPCYCLE, (2) a description of the input required by the code, (3) a listing of the input for a sample case, and (4) the output for a sample case

  6. Teachers’ Opinions in Relation to School Principals’ Organizational Power Sources andAuthentic Leadership Levels

    OpenAIRE

    NARTGÜN, Şenay Sezgin; NARTGÜN, Zekeriya; ARICI, Uzman Deniz

    2016-01-01

    The aim of this study is to determine the organizational power sources that used and authentic leadership levels that demonstrated by primary, secondary and high school principals within the framework of teachers‟ opinions. In the study, comparative survey was used. One hundred and twenty teachers of primary, secondary and high schools located at Dörtdivan and Seben provinces of Bolu are consist the working group of this study. The data gathered from the one hundred teachers whom are particip...

  7. Low-level radioactive waste management in EDF nuclear power plants (FRANCE)

    International Nuclear Information System (INIS)

    Boussard, C.

    1991-01-01

    This paper shows some recent examples of Low-level radioactive waste management in EDF nuclear power plants: - Radioactive liquid wastes proceeding from steam generators leaching (NOGENT SUR SEINE-1 REACTOR) - Thermal insulation proceeding from heat exchanger and blower (CHINON-2 REACTOR) - Old iron from reactor dismantling (CHINON-3 REACTOR, MARCOULE G1 REACTOR, MARCOULE G2-G3 REACTORS) - fresh air filter and fire detector - CHINON-2 REACTOR breaker chambers

  8. A Polymer Optical Fiber Fuel Level Sensor: Application to Paramotoring and Powered Paragliding

    Directory of Open Access Journals (Sweden)

    David Sánchez Montero

    2012-05-01

    Full Text Available A low-cost intensity-based polymer optical fiber (POF sensor for fuel level measurements in paramotoring and powered paragliding is presented, exploiting the advantages of the optical fiber sensing technology. Experimental results demonstrate that the best option can be performed by stripping the fiber at the desired discrete points to measure the fuel level as well as with a gauge-shape fiber bending. The prototype has a good linearity, better than 4% full scale (F.S., and sensitivity around 0.5 V per bend are obtained. Hysteresis due to residual fluid at the sensing points is found to be less than 9% F.S.

  9. Radiochemical methodologies applied to analytical characterization of low and intermediate level wastes from nuclear power plants

    International Nuclear Information System (INIS)

    Monteiro, Roberto Pellacani G.; Júnior, Aluísio Souza R.; Kastner, Geraldo F.; Temba, Eliane S.C.; Oliveira, Thiago C. de; Amaral, Ângela M.; Franco, Milton B.

    2017-01-01

    The aim of this work is to present radiochemical methodologies developed at CDTN/CNEN in order to answer a program for isotopic inventory of radioactive wastes from Brazilian Nuclear Power Plants. In this program some radionuclides, 3 H, 14 C, 55 Fe, 59 Ni, 63 Ni, 90 Sr, 93 Zr, 94 Nb, 99 Tc, 129 I, 235 U, 238 U, 238 Pu, 239 + 240 Pu, 241 Pu, 242 Pu, 241 Am, 242 Cm e 243 + 244 Cm, were determined in Low Level Wastes (LLW) and Intermediate Level Wastes (ILW) and a protocol of analytical methodologies based on radiochemical separation steps and spectrometric and nuclear techniques was established. (author)

  10. Differentiated influences of benefit and risk perceptions on nuclear power acceptance according to acceptance levels. Evidence from Korea

    International Nuclear Information System (INIS)

    Roh, Seungkook; Lee Jinwon

    2017-01-01

    The perceived benefit and risk of nuclear power generation have received considerable attention as determinants of the public's nuclear power acceptance. However, the contingency of the relative importance of these benefit and risk has been less explored. Using Korea as an example, this study explores the possibility that the relative importance of perceived benefit and risk on nuclear power acceptance depends on acceptance levels. Our results from latent class analysis and multinomial probit show that, in determining whether an individual shows a moderate level of nuclear power acceptance rather than a low level, perceived risk plays a dominant role compared to perceived benefit; however, regarding whether he/she shows a high level of nuclear power acceptance rather than a moderate level, this relative importance is reversed. These results carry practical implications for risk governance of nuclear power, particularly with regard to communication with the public. (author)

  11. Development and Application of Level 2 Probabilistic Safety Assessment for Nuclear Power Plants. Specific Safety Guide

    International Nuclear Information System (INIS)

    2010-01-01

    The objective of this Safety Guide is to provide recommendations for meeting the IAEA safety requirements in performing or managing a level 2 probabilistic safety assessment (PSA) project for a nuclear power plant; thus it complements the Safety Guide on level 1 PSA. One of the aims of this Safety Guide is to promote a standard framework, standard terms and a standard set of documents for level 2 PSAs to facilitate regulatory and external peer review of their results. It describes all elements of the level 2 PSA that need to be carried out if the starting point is a fully comprehensive level 1 PSA. Contents: 1. Introduction; 2. PSA project management and organization; 3. Identification of design aspects important to severe accidents and acquisition of information; 4. Interface with level 1 PSA: Grouping of sequences; 5. Accident progression and containment analysis; 6. Source terms for severe accidents; 7. Documentation of the analysis: Presentation and interpretation of results; 8. Use and applications of the PSA; Annex I: Example of a typical schedule for a level 2 PSA; Annex II: Computer codes for simulation of severe accidents; Annex III: Sample outline of documentation for a level 2 PSA study.

  12. Power infrastructure quality and manufacturing productivity in Africa: A firm level analysis

    International Nuclear Information System (INIS)

    Moyo, Busani

    2013-01-01

    This study sought to examine the impact of the quality of power infrastructure on productivity in African manufacturing firms using data from the World Bank enterprise surveys. We measured power infrastructure quality using the number of hours per day without electricity and the percentage of output lost due to outages and found these indicators to be negative and significant determinants of productivity. These variables seem to be significant determinants in Uganda, Tanzania and Zambia as well as in the food and agriculture sector. To improve economic growth and encourage employment creation, governments in Africa have to come up with measures to improve the reliability of electricity infrastructure. - Highlights: • Power infrastructure quality indicators are found to have a negative and significant effect. • The power quality indicators have varied effects both at country and sector level. • Owning a generator minimises the negative impact of outages in Uganda, Tanzania and Mauritius. • Other controls like labour, capital, foreign ownership etc. have a positive and significant effect. • The firm age variable is insignificant suggesting that accumulated knowledge does not matter

  13. Concentrated solar power plants impact on PV penetration level and grid flexibility under Egyptian climate

    Science.gov (United States)

    Moukhtar, Ibrahim; Elbaset, Adel A.; El Dein, Adel Z.; Qudaih, Yaser; Mitani, Yasunori

    2018-05-01

    Photovoltaic (PV) system integration in the electric grid has been increasing over the past decades. However, the impact of PV penetration on the electric grid, especially during the periods of higher and lower generation for the solar system at the middle of the day and during cloudy weather or at night respectively, limit the high penetration of solar PV system. In this research, a Concentrated Solar Power (CSP) with Thermal Energy Storage (TES) has been aggregated with PV system in order to accommodate the required electrical power during the higher and lower solar energy at all timescales. This paper analyzes the impacts of CSP on the grid-connected PV considering high penetration of PV system, particularly when no energy storages in the form of batteries are used. Two cases have been studied, the first when only PV system is integrated into the electric grid and the second when two types of solar energy (PV and CSP) are integrated. The System Advisor Model (SAM) software is used to simulate the output power of renewable energy. Simulation results show that the performance of CSP has a great impact on the penetration level of PV system and on the flexibility of the electric grid. The overall grid flexibility increases due to the ability of CSP to store and dispatch the generated power. In addition, CSP/TES itself has inherent flexibility. Therefore, CSP reduces the minimum generation constraint of the conventional generators that allows more penetration of the PV system.

  14. A new high-voltage level-shifting circuit for half-bridge power ICs

    International Nuclear Information System (INIS)

    Kong Moufu; Chen Xingbi

    2013-01-01

    In order to reduce the chip area and improve the reliability of HVICs, a new high-voltage level-shifting circuit with an integrated low-voltage power supply, two PMOS active resistors and a current mirror is proposed. The integrated low-voltage power supply not only provides energy for the level-shifting circuit and the logic circuit, but also provides voltage signals for the gates and sources of the PMOS active resistors to ensure that they are normally-on. The normally-on PMOS transistors do not, therefore, need to be fabricated in the depletion process. The current mirror ensures that the level-shifting circuit has a constant current, which can reduce the process error of the high-voltage devices of the circuit. Moreover, an improved RS trigger is also proposed to improve the reliability of the circuit. The proposed level-shifting circuit is analyzed and confirmed by simulation with MEDICI, and the simulation results show that the function is achieved well. (semiconductor integrated circuits)

  15. Why weight? Modelling sample and observational level variability improves power in RNA-seq analyses.

    Science.gov (United States)

    Liu, Ruijie; Holik, Aliaksei Z; Su, Shian; Jansz, Natasha; Chen, Kelan; Leong, Huei San; Blewitt, Marnie E; Asselin-Labat, Marie-Liesse; Smyth, Gordon K; Ritchie, Matthew E

    2015-09-03

    Variations in sample quality are frequently encountered in small RNA-sequencing experiments, and pose a major challenge in a differential expression analysis. Removal of high variation samples reduces noise, but at a cost of reducing power, thus limiting our ability to detect biologically meaningful changes. Similarly, retaining these samples in the analysis may not reveal any statistically significant changes due to the higher noise level. A compromise is to use all available data, but to down-weight the observations from more variable samples. We describe a statistical approach that facilitates this by modelling heterogeneity at both the sample and observational levels as part of the differential expression analysis. At the sample level this is achieved by fitting a log-linear variance model that includes common sample-specific or group-specific parameters that are shared between genes. The estimated sample variance factors are then converted to weights and combined with observational level weights obtained from the mean-variance relationship of the log-counts-per-million using 'voom'. A comprehensive analysis involving both simulations and experimental RNA-sequencing data demonstrates that this strategy leads to a universally more powerful analysis and fewer false discoveries when compared to conventional approaches. This methodology has wide application and is implemented in the open-source 'limma' package. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  16. A detector for monitoring the onset of cavitation during therapy-level measurements of ultrasonic power

    Energy Technology Data Exchange (ETDEWEB)

    Hodnett, M; Zeqiri, B [National Physical Laboratory, Queens Road, Teddington, Middlesex, TW11 0LW (United Kingdom)

    2004-01-01

    Acoustic cavitation occurring in the water path between a transducer and the target of a radiation force balance can provide a significant source of error during measurements of ultrasonic power. These problems can be particularly acute at physiotherapy levels (>1 W), and low frequencies ({<=} 1 MHz). The cavitating bubbles can absorb and scatter incident ultrasound, leading to an underestimate in the measured power. For these reasons, International Specification standards demand the use of degassed water. This imposes requirements that may actually be difficult to meet, for example, in the case of hospitals. Also, initially degassed water will rapidly re-gas, increasing the likelihood of cavitation occurring. For these reasons, NPL has developed a device that monitors acoustic emissions generated by bubble activity, for detecting the onset of cavitation during power measurements. A commercially available needle hydrophone is used to detect these emissions. The acoustic signals are then monitored using a Cavitation Detector (CD) unit, comprising an analogue electrical filter that may be tuned to detect frequency components generated by cavitating bubbles, and which provides an indication of when the measured level exceeds a pre-defined threshold. This paper describes studies to establish a suitable detection scheme, the principles of operation of the CD unit, and the performance tests carried out with a range of propagation media.

  17. Radioactivity level of soil around Baqiao coal-fired power plant in China

    International Nuclear Information System (INIS)

    Lu, Xinwei; Zhao, Caifeng; Chen, Cancan; Liu, Wen

    2012-01-01

    Natural radioactivity level of soil around Baqiao coal-fired power plant in China was determined using gamma ray spectrometry. The concentrations of 226 Ra, 232 Th and 40 K in the studied soil samples range from 27.6 to 48.8, 44.4 to 61.4 and 640.2 to 992.2 Bq kg −1 with an average of 36.1, 51.1 and 733.9 Bq kg −1 , respectively, which are slightly higher than the average values of Shaanxi soil. The radium equivalent activity, the air absorbed dose rate and the annual effective dose rate were calculated and compared with the internationally reported or reference values. The radium equivalent activities of the studied samples are below the internationally accepted values. The air absorbed dose rate and the annual effective dose rate received by the local residents due to the natural radionuclides in soil are slightly higher than the mean value of Xi'an and worldwide. - Highlights: ► Natural radioactivity in soil around the coal-fired power plant was determined. ► Radiological parameters were used to assess radiation hazard. ► The coal-fired power plant has affected the local radioactivity level.

  18. Integrated Level 3 risk assessment for the LaSalle Unit 2 nuclear power plant

    International Nuclear Information System (INIS)

    Payne, A.C. Jr.; Brown, T.D.; Miller, L.A.

    1991-01-01

    An integrated Level 3 probabilistic risk assessment (PRA) was performed on the LaSalle County Station nuclear power plant using state-of-the-art PRA analysis techniques. The objective of this study was to provide an estimate of the risk to the offsite population during full power operation of the plant and to include a characterization of the uncertainties in the calculated risk values. Uncertainties were included in the accident frequency analysis, accident progression analysis, and the source term analysis. Only weather uncertainties were included in the consequence analysis. In this paper selected results from the accident frequency, accident progression, source term, consequence, and integrated risk analyses are discussed and the methods used to perform a fully integrated Level 3 PRA are examined. LaSalle County Station is a two-unit nuclear power plant located 55 miles southwest of Chicago, Illinois. Each unit utilizes a Mark 2 containment to house a General Electric 3323 MWt BWR-5 reactor. This PRA, which was performed on Unit 2, included internal as well as external events. External events that were propagated through the risk analysis included earthquakes, fires, and floods. The internal event accident scenarios included transients, transient-induced LOCAs (inadvertently stuck open relief valves), anticipated transients without scram, and loss of coolant accidents

  19. Islanding the power grid on the transmission level: less connections for more security

    Science.gov (United States)

    Mureddu, Mario; Caldarelli, Guido; Damiano, Alfonso; Scala, Antonio; Meyer-Ortmanns, Hildegard

    2016-10-01

    Islanding is known as a management procedure of the power system that is implemented at the distribution level to preserve sensible loads from outages and to guarantee the continuity in electricity supply, when a high amount of distributed generation occurs. In this paper we study islanding on the level of the transmission grid and shall show that it is a suitable measure to enhance energy security and grid resilience. We consider the German and Italian transmission grids. We remove links either randomly to mimic random failure events, or according to a topological characteristic, their so-called betweenness centrality, to mimic an intentional attack and test whether the resulting fragments are self-sustainable. We test this option via the tool of optimized DC power flow equations. When transmission lines are removed according to their betweenness centrality, the resulting islands have a higher chance of being dynamically self-sustainable than for a random removal. Less connections may even increase the grid’s stability. These facts should be taken into account in the design of future power grids.

  20. A detector for monitoring the onset of cavitation during therapy-level measurements of ultrasonic power

    International Nuclear Information System (INIS)

    Hodnett, M; Zeqiri, B

    2004-01-01

    Acoustic cavitation occurring in the water path between a transducer and the target of a radiation force balance can provide a significant source of error during measurements of ultrasonic power. These problems can be particularly acute at physiotherapy levels (>1 W), and low frequencies (≤ 1 MHz). The cavitating bubbles can absorb and scatter incident ultrasound, leading to an underestimate in the measured power. For these reasons, International Specification standards demand the use of degassed water. This imposes requirements that may actually be difficult to meet, for example, in the case of hospitals. Also, initially degassed water will rapidly re-gas, increasing the likelihood of cavitation occurring. For these reasons, NPL has developed a device that monitors acoustic emissions generated by bubble activity, for detecting the onset of cavitation during power measurements. A commercially available needle hydrophone is used to detect these emissions. The acoustic signals are then monitored using a Cavitation Detector (CD) unit, comprising an analogue electrical filter that may be tuned to detect frequency components generated by cavitating bubbles, and which provides an indication of when the measured level exceeds a pre-defined threshold. This paper describes studies to establish a suitable detection scheme, the principles of operation of the CD unit, and the performance tests carried out with a range of propagation media

  1. Advanced I and C system of security level for nuclear power station

    International Nuclear Information System (INIS)

    Liu Yanyang

    2001-01-01

    Advanced I and C system of security level using for PWR developed by Framatome and Schneider collective, SPINLINE3, are introduced. The technology is used to outside reactor nuclear measurement system in Qinshan II period. It's succeed benefits by Framatome and Schneider's more years development experience in nuclear power station digitallization security level I and C system field, which improve security and reliability of PWR, and, easy operation and maintains. SPINLINE3 based on digitallization and modularization technical proposal, and covered entireness reactor protect system and correlative control system. The paper also introduce CLARISSE (computer aided design aid) and SCADE (embedded software aid) for developing SPINLINE3. SPINLINE3 fills correlative IS and rule, based on software and hardware unit which certificate and launch into operation. After brief review of Framatome and Schneider's experience, the paper are introducing design guideline, application technology and how to fill demand of security level I and C system

  2. A level III PSA for the inherently safe CAREM-25 nuclear power station

    International Nuclear Information System (INIS)

    Baron, Jorge H.; Nunez McLeod, J.; Rivera, S.S.

    2000-01-01

    A Level III PSA has been performed for the inherently safe CAREM-25 nuclear power station, as a requirement for licensing according to argentinian regulations. The CAREM-25 project is still at a detailed design state, therefore only internal events have been considered, and a representative site has been assumed for dose estimations. Several conservative hypothesis have been formulated, but even so an overall core melt frequency of 2.3E -5 per reactor year has been obtained. The risk estimations comply with the regulations. The risk values obtained are compared to the 700MW(e) nuclear power plant Atucha II PSA result, showing an effective risk reduction not only in the severe accident probability but alto in the consequence component of the risk estimation. (author)

  3. Creation of nuclear power stations for export. Adapting a reference power station from the technical level of a national programme

    International Nuclear Information System (INIS)

    Marcaillou, J.; Haond, H.; Py, J.P.

    1977-01-01

    The recent evolution of primary energy supplies places those countries with a nuclear industry in an exporting role. Exporting countries have generally developed a limited number of national reactor types and attempt to extend their manufacture with as few changes as possible. The EDF in France is implementing an important 900-MW(e) PWR programme based on Framatome nuclear reactors, initially conceived by Westinghouse. Standardization imposes constraints, has limits, but offers incontestable advantages in terms of reliability, availability and security. These advantages were highly appreciated during the introduction into service of conventional thermal loads. Importing countries are all concerned to purchase a proven model. However, various local restrictions are often present, which are usually different from those accounted for in the export model, thus resulting in a need for modification. The different ways of considering the inescapable constraints can be analysed and their influence on the 'disfigurement' of the reactor model can be examined. Some of these constraints are connected with characteristics of the site. The nature of the soil and the seismicity influence the foundation and the depth of the installation and the choice between a foundation on antiseismic supports or structural reinforcement. The hydrology (risk of flooding or of deviation of the cold source) influences the choice between elevation of the installation and a protective dike, and also the stand-by coolant circuit. The atmospheric conditions and the temperature of cooling water influence the materials and their conditioning as well as the power level of the station. The surrounding demography influences the waste treatment systems. The characteristics of the electricity network influence the plan of the electric power supply and the conditions of operation. Finally, the characteristics of the personnel of the undertaking provide training problems. Other parameters to be taken into

  4. A cell-level power management IC in BCD-SOI for partial power processing in Concentrating-PV systems

    NARCIS (Netherlands)

    Zaman, M.S.; Wen, Y.; Fernandes, R.; Buter, B.; Doorn, T.S.; Dijkstra, M.; Bergveld, H.J.; Trescases, O.

    2014-01-01

    This work presents a power management IC used to mitigate the effects of mismatch in Concentrating-Photovoltaic (CPV) systems. The IC contains a bi-directional dc-dc converter, an auxiliary boost converter to generate the internal 10 V power supply, as well as protection and monitoring circuits. The

  5. A Prediction Packetizing Scheme for Reducing Channel Traffic in Transaction-Level Hardware/Software Co-Emulation

    OpenAIRE

    Lee , Jae-Gon; Chung , Moo-Kyoung; Ahn , Ki-Yong; Lee , Sang-Heon; Kyung , Chong-Min

    2005-01-01

    Submitted on behalf of EDAA (http://www.edaa.com/); International audience; This paper presents a scheme for efficient channel usage between simulator and accelerator where the accelerator models some RTL sub-blocks in the accelerator-based hardware/software co-simulation while the simulator runs transaction-level model of the remaining part of the whole chip being verified. With conventional simulation accelerator, evaluations of simulator and accelerator alternate at every valid simulation ...

  6. Experimental study on an S-band near-field microwave magnetron power transmission system on hundred-watt level

    Science.gov (United States)

    Zhang, Biao; Jiang, Wan; Yang, Yang; Yu, Chengyang; Huang, Kama; Liu, Changjun

    2015-11-01

    A multi-magnetron microwave source, a metamaterial transmitting antenna, and a large power rectenna array are presented to build a near-field 2.45 GHz microwave power transmission system. The square 1 m2 rectenna array consists of sixteen rectennas with 2048 Schottky diodes for large power microwave rectifying. It receives microwave power and converts them into DC power. The design, structure, and measured performance of a unit rectenna as well as the entail rectenna array are presented in detail. The multi-magnetron microwave power source switches between half and full output power levels, i.e. the half-wave and full-wave modes. The transmission antenna is formed by a double-layer metallic hole array, which is applied to combine the output power of each magnetron. The rectenna array DC output power reaches 67.3 W on a 1.2 Ω DC load at a distance of 5.5 m from the transmission antenna. DC output power is affected by the distance, DC load, and the mode of microwave power source. It shows that conventional low power Schottky diodes can be applied to a microwave power transmission system with simple magnetrons to realise large power microwave rectifying.

  7. Allowable Residual Contamination Levels in soil for decommissioning the Shippingport Atomic Power Station site

    International Nuclear Information System (INIS)

    Kennedy, W.E. Jr.; Napier, B.A.; Soldat, J.K.

    1983-09-01

    As part of decommissioning the Shippingport Atomic Power Station, a fundamental concern is the determination of Allowable Residual Contamination Levels (ARCL) for radionuclides in the soil at the site. The ARCL method described in this report is based on a scenario/exposure-pathway analysis and compliance with an annual dose limit for unrestricted use of the land after decommissioning. In addition to naturally occurring radionuclides and fallout from weapons testing, soil contamination could potentially come from five other sources. These include operation of the Shippingport Station as a pressurized water reactor, operations of the Shippingport Station as a light-water breeder, operation of the nearby Beaver Valley reactors, releases during decommissioning, and operation of other nearby industries, including the Bruce-Mansfield coal-fired power plants. ARCL values are presented for 29 individual radionculides and a worksheet is provided so that ARCL values can be determined for any mixture of the individual radionuclides for any annual dose limit selected. In addition, a worksheet is provided for calculating present time soil concentration value that will decay to the ARCL values after any selected period of time, such as would occur during a period of restricted access. The ARCL results are presented for both unconfined (surface) and confined (subsurface) soil contamination. The ARCL method and results described in this report provide a flexible means of determining unrestricted-use site release conditions after decommissioning the Shippingport Atomic Power Station

  8. What day-ahead reserves are needed in electric grids with high levels of wind power?

    International Nuclear Information System (INIS)

    Mauch, Brandon; Apt, Jay; Jaramillo, Paulina; Carvalho, Pedro M S

    2013-01-01

    Day-ahead load and wind power forecasts provide useful information for operational decision making, but they are imperfect and forecast errors must be offset with operational reserves and balancing of (real time) energy. Procurement of these reserves is of great operational and financial importance in integrating large-scale wind power. We present a probabilistic method to determine net load forecast uncertainty for day-ahead wind and load forecasts. Our analysis uses data from two different electric grids in the US with similar levels of installed wind capacity but with large differences in wind and load forecast accuracy, due to geographic characteristics. We demonstrate that the day-ahead capacity requirements can be computed based on forecasts of wind and load. For 95% day-ahead reliability, this required capacity ranges from 2100 to 5700 MW for ERCOT, and 1900 to 4500 MW for MISO (with 10 GW of installed wind capacity), depending on the wind and load forecast values. We also show that for each MW of additional wind power capacity for ERCOT, 0.16–0.30 MW of dispatchable capacity will be used to compensate for wind uncertainty based on day-ahead forecasts. For MISO (with its more accurate forecasts), the requirement is 0.07–0.13 MW of dispatchable capacity for each MW of additional wind capacity. (letter)

  9. Evaluating the level and nature of sustainable development for a geothermal power plant

    International Nuclear Information System (INIS)

    Phillips, Jason

    2010-01-01

    The paper provides for an evaluation of the potential level and nature of sustainable development of the Sabalan geothermal power plant in NW Iran, to be operational in 2011. The paper achieves this by applying a mathematical model of sustainable development developed by the author (re: Phillips), in respect to the Environmental Impact Assessment (EIA) conducted by Yousefi et al. using the Rapid Impact Assessment Matrix (RIAM) methodology (re: Pastakia; Pastakia and Jensen). Using a model application methodology developed for the RIAM, the results indicated that the nature of sustainable development for Sabalan was considered to be very weak (S = 0.063). This was due to the imbalance between negative environmental impacts and positive socio-economic impacts deriving from the project. Further, when placed into context with a similar set of results obtained from the EIA of the Tuzla geothermal power plant by Baba also using the RIAM methodology, then the similarities between the results obtained raises some legimate questions as to the sustainable development credentials of geothermal power production. (author)

  10. De minimis applications for alternative disposal of very low level radioactive waste at Duke Power Company

    International Nuclear Information System (INIS)

    Lan, C.

    1986-01-01

    Existing NRC regulations provide no minimum level of radioactivity in waste from a licensee's facility that may be disposed of in a manner other than as radioactive waste. With one exception, in 10CFRsection20.306, licensees may dispose of certain levels of tritium and carbon-14 in liquid-scintillation and animal-carcass waste without regard to its radioactivity. In the interim, before specific or generic provisions for disposing of very low level radioactive wastes are adopted through rule making, licensees have another alternative for obtaining approval to dispose of large volumes of materials contaminated with very low levels of radioactivity under provision 10CFRsection20.302(a) ''Method for obtaining approval of proposed disposal procedures.'' This paper provides the experiences of obtaining both NRC and states (North Carolina and South Carolina) approval for disposing of very low-level radioactive wastes from Duke Power Company's nuclear stations. The approved disposal procedures include landfarming of water treatment residues, on-site disposal (burial) of sand and feedwater heaters, and include offsite release for treatment and disposal of sanitary sewage sludge. In summary, users of radioactive materials should not exclude this approach in their quest to reduce the volume of radioactive waste. It is expected that such submittals could provide a data base for further development of generic limits for radioactive wastes

  11. Radiochemical methodologies applied to analytical characterization of low and intermediate level wastes from nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Roberto Pellacani G.; Júnior, Aluísio Souza R.; Kastner, Geraldo F.; Temba, Eliane S.C.; Oliveira, Thiago C. de; Amaral, Ângela M.; Franco, Milton B., E-mail: rpgm@cdtn.br, E-mail: reisas@cdtn.br, E-mail: gfk@cdtn.br, E-mail: esct@cdtn.br, E-mail: tco@cdtn.br, E-mail: ama@cdtn.br, E-mail: francom@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    The aim of this work is to present radiochemical methodologies developed at CDTN/CNEN in order to answer a program for isotopic inventory of radioactive wastes from Brazilian Nuclear Power Plants. In this program some radionuclides, {sup 3}H, {sup 14}C, {sup 55}Fe, {sup 59}Ni, {sup 63}Ni, {sup 90}Sr, {sup 93}Zr, {sup 94}Nb, {sup 99}Tc, {sup 129}I, {sup 235}U, {sup 238}U, {sup 238}Pu, {sup 239}+{sup 240}Pu, {sup 241}Pu, {sup 242}Pu, {sup 241}Am, {sup 242}Cm e {sup 243}+{sup 244}Cm, were determined in Low Level Wastes (LLW) and Intermediate Level Wastes (ILW) and a protocol of analytical methodologies based on radiochemical separation steps and spectrometric and nuclear techniques was established. (author)

  12. Radioactivity level of the ambient environment of Anren bone-coal power station

    International Nuclear Information System (INIS)

    Ye Jida; Liu Hongshi; Wu Zongmei; Wu Xiaofei

    2002-01-01

    The radioactivity level of the ambient environment of Anren Bone-coal Power Station (BCPS) was investigated systematically. The γ radiation dose rate level in the environment, the content of 238 U and 226 Ra in the ambient soil and the farmland in the direction of downwind, the concentrations of 238 U, 232 Th, 226 Ra, 40 K and 222 Rn, as well as α potential energy in air, and the concentrations of natural U and Th in effluent are all higher than the corresponding values of the reference site. The additional annual effective dose equivalent to the residents living in the houses made of bone-coal cinder brick is 2.7 mSv

  13. Effect of heliostat size on the levelized cost of electricity for power towers

    Science.gov (United States)

    Pidaparthi, Arvind; Hoffmann, Jaap

    2017-06-01

    The objective of this study is to investigate the effects of heliostat size on the levelized cost of electricity (LCOE) for power tower plants. These effects are analyzed in a power tower with a net capacity of 100 MWe, 8 hours of thermal energy storage and a solar multiple of 1.8 in Upington, South Africa. A large, medium and a small size heliostat with a total area of 115.56 m2, 43.3 m2 and 15.67 m2 respectively are considered for comparison. A radial-staggered pattern and an external cylindrical receiver are considered for the heliostat field layouts. The optical performance of the optimized heliostat field layouts has been evaluated by the Hermite (analytical) method using SolarPILOT, a tool used for the generation and optimization of the heliostat field layout. The heliostat cost per unit is calculated separately for the three different heliostat sizes and the effects due to size scaling, learning curve benefits and the price index is included. The annual operation and maintenance (O&M) costs are estimated separately for the three heliostat fields, where the number of personnel required in the field is determined by the number of heliostats in the field. The LCOE values are used as a figure of merit to compare the different heliostat sizes. The results, which include the economic and the optical performance along with the annual O&M costs, indicate that lowest LCOE values are achieved by the medium size heliostat with an area of 43.3 m2 for this configuration. This study will help power tower developers determine the optimal heliostat size for power tower plants currently in the development stage.

  14. Direct Power Control for Three-Phase Two-Level Voltage-Source Rectifiers Based on Extended-State Observation

    DEFF Research Database (Denmark)

    Song, Zhanfeng; Tian, Yanjun; Yan, Zhuo

    2016-01-01

    This paper proposed a direct power control strategy for three-phase two-level voltage-source rectifiers based on extended-state observation. Active and reactive powers are directly regulated in the stationary reference frame. Similar to the family of predictive controllers whose inherent characte......This paper proposed a direct power control strategy for three-phase two-level voltage-source rectifiers based on extended-state observation. Active and reactive powers are directly regulated in the stationary reference frame. Similar to the family of predictive controllers whose inherent...

  15. Grid Connection of Wave Power Farm Using an N-Level Cascaded H-Bridge Multilevel Inverter

    Directory of Open Access Journals (Sweden)

    Rickard Ekström

    2013-01-01

    Full Text Available An N-level cascaded H-bridge multilevel inverter is proposed for grid connection of large wave power farms. The point-absorber wave energy converters are individually rectified and used as isolated DC-sources. The variable power characteristics of the wave energy converters are discussed, and a method of mitigating this issue is demonstrated. The complete power control system is given in detail and has been experimentally verified for a single-phase setup of the 9-level inverter. Theoretical expressions of the power sharing between multilevel cells are derived and show good correspondence with the experimental results.

  16. Level 1 shutdown and low power operation of Mochovce NPP, Unit 1, Slovakia

    International Nuclear Information System (INIS)

    Halada, P.; Cillik, I.; Stojka, T.; Kuzma, M.; Prochaska, J.; Vrtik, L.

    2004-01-01

    The paper presents general approach, used methods and form of documentation of the results that have been applied within the shutdown and low power PSA (SPSA) study for Mochovce NPP, Unit 1, Slovakia. The SPSA project was realized by VUJE Trnava Inc., Slovakia in 2001-2002 years. The Level 1 SPSA study for Mochovce NPP Unit 1 covers internal events as well as internal (fires, floods and heavy load drop) and external (aircraft crash, extreme meteorological conditions, seismic event and influence of surrounding industry) hazards. Mochovce NPP consists of two operating units equipped with VVER 440/V213 reactors safety upgraded before construction finishing and operation start. 87 safety measures based on VVER 440 operational experience and international mission insights were implemented to enhance its operational and nuclear safety. The SPSA relates to full power PSA (FPSA) as a continuation of the effort to create a harmonized level 1 PSA model for all operational modes of the plant with the goal to use it for further purposes as follows: Real Time Risk Monitor, Maintenance Optimization, Technical Specifications Optimization, Living PSA. (author)

  17. Operation and thermal loading of three-level Neutral-Point-Clamped wind power converter under various grid faults

    DEFF Research Database (Denmark)

    Ma, Ke; Blaabjerg, Frede; Liserre, Marco

    2012-01-01

    In order to fulfill the continuous growing grid-side demands, the full-scale power converters are becoming more and more popular in the wind power application. Nevertheless, the more severe loading of the power semiconductor devices in the full-scale power converters, especially during Low Voltage...... Ride Through (LVRT) operation under grid faults, may compromise the reliability of the system and consequently further increase its cost. In this paper, the impact of various grid faults on a three-level Neutral-Point-Clamped (3L-NPC) grid-converter in terms of thermal loading of power semiconductor...

  18. Trending of low level events and near misses to enhance safety performance in nuclear power plants

    International Nuclear Information System (INIS)

    2005-11-01

    The IAEA Safety Fundamentals publication, Safety of Nuclear Installations, Safety Series No. 110, states the need for operating organizations to establish a programme for the collection and analysis of operating experience in nuclear power plants. Such a programme ensures that operating experience is analysed, events important to safety are reviewed in depth, and lessons learned are disseminated to the staff of the organization and to relevant national and international organizations. As a result of the effort to enhance safety in operating organizations, incidents are progressively decreasing in number and significance. This means that in accordance with international reporting requirements the amount of collected data becomes less sufficient to draw meaningful statistical conclusions. This is where the collection and trend analysis of low level events and near misses can prove to be very useful. These trends can show which of the safety barriers are weak or failing more frequently. Evaluation and trending of low level events and near misses will help to prevent major incidents because latent weaknesses have been identified and corrective actions taken to prevent recurrence. This leads to improved safety and production. Low level events and near misses, which may reach several thousand per reactor operating year, need to be treated by the organizations as learning opportunities. A system for capturing these low level events and near misses truly needs to be an organization-wide system in which all levels of the organization, including contractors, participate. It is desirable that the overall operational experience feedback (OEF) process should integrate the lessons learned and the associated data from significant events with those of lower level events and near misses. To be able to effectively implement a process dealing with low level events and near misses, it is necessary that the organization have a well established OEF process for significant events

  19. Comparison of p53 levels in lymphocytes and in blood plasma of nuclear power plant workers

    International Nuclear Information System (INIS)

    Roessner, Pavel; Chvatalova, Irena; Schmuczerova, Jana; Milcova, Alena; Roessner, Pavel; Sram, Radim J.

    2004-01-01

    p53 levels were assessed in lymphocytes and in blood plasma of workers from two Czech nuclear power plants (NPP): 114 subjects working in Temelin and 108 subjects working in Dukovany. Ionizing radiation (IR) exposure data were available for 64 and 59 subjects working in the monitored zones from the NPP in Temelin and Dukovany, respectively. The short-term doses of IR for these subjects were 0.01 and 0.12 mSv, and the long-term doses were 0.46 and 5.68 mSv, in the Temelin and Dukovany NPP, respectively. As a control group, 46 subjects living in Ceske Budejovice, a city nearby the Temelin NPP, were analyzed. The concentration of p53 in lymphocytes was significantly higher in workers from the monitored zone in the Dukovany NPP (median value 6.4 pg/μg protein, P < 0.001) than in workers from the Temelin NPP (3.2 pg/μg) as well as in the control group (3.5 pg/μg). In contrast, plasma levels of p53 were comparable in the control group (median value 116 pg/ml plasma) and workers from the monitored zone of Dukovany NPP (102 pg/ml), but lower in workers from Temelin NPP (5 pg/ml). Other factors affecting p53 levels were studied. Smoking resulted in increased p53 lymphocyte levels. The effect of polymorphisms in metabolic and DNA repair genes on p53 levels was analyzed. The correlation was found between p53 levels in lymphocytes and p53 codon 72 polymorphism in subjects working in NPPs, but not in the control group. The results of measurement p53 levels in lymphocytes suggest that this biomarker could reflect the short-term as well as long-term effects of low doses IR. Its impact on human health should be further explored

  20. On-chip power-combining techniques for watt-level linear power amplifiers in 0.18 μm CMOS

    International Nuclear Information System (INIS)

    Ren Zhixiong; Zhang Kefeng; Liu Lanqi; Li Cong; Chen Xiaofei; Liu Dongsheng; Liu Zhenglin; Zou Xuecheng

    2015-01-01

    Three linear CMOS power amplifiers (PAs) with high output power (more than watt-level output power) for high data-rate mobile applications are introduced. To realize watt-level output power, there are two 2.4 GHz PAs using an on-chip parallel combining transformer (PCT) and one 1.95 GHz PA using an on-chip series combining transformer (SCT) to combine output signals of multiple power stages. Furthermore, some linearization techniques including adaptive bias, diode linearizer, multi-gated transistors (MGTR) and the second harmonic control are applied in these PAs. Using the proposed power combiner, these three PAs are designed and fabricated in TSMC 0.18 μm RFCMOS process. According to the measurement results, the proposed two linear 2.4 GHz PAs achieve a gain of 33.2 dB and 34.3 dB, a maximum output power of 30.7 dBm and 29.4 dBm, with 29% and 31.3% of peak PAE, respectively. According to the simulation results, the presented linear 1.95 GHz PA achieves a gain of 37.5 dB, a maximum output power of 34.3 dBm with 36.3% of peak PAE. (paper)

  1. Load leveling efforts of The Hokkaido Electric Power Co. Inc.; Hokkaido Denryoku no fuka heijunka eno torikumi ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-04-01

    The Hokkaido Electric Power Co., Inc., aiming to enhance power generation efficiency through power load levelling, strives to expand and substantiate its electricity billing menu and to popularize and encourage the use of levelling-oriented apparatuses and systems most of which are designed for utilizing midnight power. The billing menu has in it a snow-melting power which is cut off for load levelling during the peak demand time zone. For domestic use, a time zone-specified lighting system named Dream Eight is created, which is one of the billing systems dependent upon time zone. Introduced therein for industrial use is a demand/supply adjustment contract system. Furthermore, in compliance with the amended Electricity Business Law that came into force in 1995, efforts are under way for revising the period wherein power is to be supplied for melting snow, expanding the scope of application of the power supply system dependent upon time zone, and newly introducing a heat accumulation assisted peak adjustment contract system and an operation adjustment contract system. As for business efforts in relation to load levelling, the company proposes household electrical systems centering about 200V high-efficiency apparatuses, electric water warmer contributing to the enhancement of year-round load levelling, popularization and reinforcement of electric snow melting systems, and power utilizing technologies capable of meeting local demands raised for example by agriculture and fishery.

  2. Low Level Event and Near Miss Process for Nuclear Power Plants: Best Practices

    International Nuclear Information System (INIS)

    2012-01-01

    The IAEA programme on the operational safety of nuclear power plants gives priority to the development and promotion of the proper use of IAEA safety standards through the provision of assistance to Member States in the application of safety standards, the performance of safety review missions and the conduct of training activities based on safety standards. A number of IAEA safety standards and nuclear safety publications discuss the processes that need to be put into place for the feedback and analysis of operating experience (OE) at nuclear power plants. These include: Fundamental Safety Principles (IAEA Safety Standards Series No. SF-1), Safety of Nuclear Power Plants: Commissioning and Operation (IAEA Safety Standards Series No. SSR-2/2), Application of the Management System for Facilities and Activities (IAEA Safety Standards Series No. GS-G-3.1) and A System for the Feedback of Experience from Events in Nuclear Installations (IAEA Safety Standards Series No. NS-G-2.11). Additionally, several IAEA TECDOCs cover many aspects of the establishment, conduct and continuous improvement of an OE programme at nuclear power plants, including the consideration of low level events (LLEs) and near misses (NMs). Although these IAEA safety standards and nuclear safety publications have been in existence for several years, 70 per cent of the IAEA Operational Safety Review Team (OSART) missions carried out at nuclear power plants between 2006 and 2010 identified weaknesses in the reporting and analysis process for LLEs and NMs. In fact, this has been one of the recurring issues most often identified in the area of OE during these missions. These weaknesses have been further confirmed by most of the IAEA Peer Review of the Operational Safety Performance Experience (PROSPER) missions that have been conducted to date. Finally, the IAEA International Nuclear Safety Group, in their report entitled Improving the International System for Operating Experience Feedback (INSAG-23

  3. Thermal Equilibrium Dynamic Control Based on DPWM Dual-Mode Modulation of High Power NPC Three-Level Inverter

    OpenAIRE

    Xu, Shi-Zhou; He, Feng-You

    2016-01-01

    In some special applications of NPC three-level inverters, such as mine hoist, there exist special conditions of overloading during the whole hoisting process and large overload in starting stage, during which the power-loss calculation of power devices and thermal control are important factors affecting the thermal stability of inverters. The principles of SVPWM and DPWM were described in this paper firstly, based on which the dynamic power losses of the two modulations of hoist in single pe...

  4. Fourier power spectrum characteristics of face photographs: attractiveness perception depends on low-level image properties.

    Science.gov (United States)

    Menzel, Claudia; Hayn-Leichsenring, Gregor U; Langner, Oliver; Wiese, Holger; Redies, Christoph

    2015-01-01

    We investigated whether low-level processed image properties that are shared by natural scenes and artworks - but not veridical face photographs - affect the perception of facial attractiveness and age. Specifically, we considered the slope of the radially averaged Fourier power spectrum in a log-log plot. This slope is a measure of the distribution of special frequency power in an image. Images of natural scenes and artworks possess - compared to face images - a relatively shallow slope (i.e., increased high spatial frequency power). Since aesthetic perception might be based on the efficient processing of images with natural scene statistics, we assumed that the perception of facial attractiveness might also be affected by these properties. We calculated Fourier slope and other beauty-associated measurements in face images and correlated them with ratings of attractiveness and age of the depicted persons (Study 1). We found that Fourier slope - in contrast to the other tested image properties - did not predict attractiveness ratings when we controlled for age. In Study 2A, we overlaid face images with random-phase patterns with different statistics. Patterns with a slope similar to those in natural scenes and artworks resulted in lower attractiveness and higher age ratings. In Studies 2B and 2C, we directly manipulated the Fourier slope of face images and found that images with shallower slopes were rated as more attractive. Additionally, attractiveness of unaltered faces was affected by the Fourier slope of a random-phase background (Study 3). Faces in front of backgrounds with statistics similar to natural scenes and faces were rated as more attractive. We conclude that facial attractiveness ratings are affected by specific image properties. An explanation might be the efficient coding hypothesis.

  5. Assessment of environmental gamma radiation levels in the environs of Narora Atomic Power Station (NAPS)

    International Nuclear Information System (INIS)

    Shetty, P.G.; Takale, R.A.; Swarnkar, M.; Sahu, S.K.; Pandit, G.G.; Puranik, V.D.

    2011-01-01

    As a part of the assessment of the environmental impact of the Indian nuclear power programme, radiation surveys are being carried out on continuous basis in the environs of all the nuclear facilities in India using Thermoluminescent Dosimeters. This paper discusses the environmental gamma radiation levels based on the analysis of data generated for year 1989-2009 at twenty-eight locations currently being monitored in and around the environs of NAPS using passive dosimeter. Of these, six are within the exclusion zone (1.6 km) while the remaining twenty two locations are spread over an aerial distance of twenty six km from reactor stack. The annual background gamma levels for NAPS site beyond 1.6 km exclusion zone based on twenty-two monitoring locations are evaluated and seen to be 1.20 ± 0.15 mGy/a. This is comparable with earlier reported pre-operational value 1.24 ± 0.26 mGy/a. From this it can be said that the reactor operations have not contributed to any increase in the gamma radiation levels in the environs of the NAPS region. (author)

  6. Development of Soil Derived Concentration Guidance Levels for Decommissioning at Overseas Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Wook; Yoon, Suk Bon; Kim, Jeongju [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    In Korea, the criteria are expected to be given in terms of dose as in US and Spain. However, since dose cannot be measured, corresponding measurable concentration limits, so-called Derived Concentration Guidance Levels (DCGLs), should be developed for each radionuclide which is expected to be present in the site. Also, as they serve as a goal of decommissioning and direct dismantling and decontamination methods applicable to the site, DCGLs should be developed in the early phase of decommissioning. This paper describes how each overseas nuclear power plant developed its site-specific Soil DCGLs: what kind of post closure use of the site (scenario) was assumed and how the site-specific Soil DCGLs were calculated based on the scenario assumed for each plant. Through this, it is intended to derive lessons learned which will be instructive for future decommissioning of domestic nuclear power plants including Kori Unit 1. It is very important to have as good under-standing as possible of characteristics of the site by collection of relevant information and data in order to apply a scenario which is most foreseeable and plausible for a site to be decommissioned and to provide site-specific inputs to the calculation of the Soil DCGLs. These efforts will help to have not-overly conservative values for the Soil DCGLs, thus thereby reducing the costs and time needed for performing the decommissioning.

  7. Levelized Cost of Energy Analysis of a Wind Power Generation System at Búrfell in Iceland

    Directory of Open Access Journals (Sweden)

    Birgir Freyr Ragnarsson

    2015-09-01

    Full Text Available Wind energy harnessing is a new energy production alternative in Iceland. Current installed wind power in Iceland sums to 1.8 MW, which in contrast is 0.1% of the country’s total electricity production. This article is dedicated to the exploration of the potential cost of wind energy production at Búrfell in the south of Iceland. A levelized cost of energy (LCOE approach was applied to the estimation of the potential cost. Weibull simulation is used to simulate wind data for calculations. A confirmation of the power law is done by comparing real data to calculated values. A modified Weibull simulation is verified by comparing results with actual on-site test wind turbines. A wind farm of 99MWis suggested for the site. Key results were the capacity factor (CF at Búrfell being 38.15% on average and that the LCOE for wind energy was estimated as 0.087–0.088 USD/kWh (assuming 10% weighted average cost of capital (WACC, which classifies Búrfell among the lowest LCOE sites for wind energy in Europe.

  8. Some Comparisons of Measured and Predicted Primary Radiation Levels in the Aagesta Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Aalto, E; Sandlin, R; Krell, Aa

    1968-05-15

    Neutron fluxes and gamma exposure rates in the primary shields of the Aagesta nuclear plant have been measured and the results compared with values predicted during shield design, and with values obtained later by the NRN bulk shielding code. The input data for the problems are given. The radial predictions are conservative by a factor of not more than 2 close to the reactor and by an unknown, higher factor further out. The conservatism is explainable by the differences between the true local conditions and core power distributions and those assumed in the predictions. The axial flux levels based on streaming calculations are found to agree quite well with the estimated values. The conservatism here is not so large and it seems to be necessary to be very careful when handling streaming problems. The experience gained shows that a power plant is less suitable for studying the accuracy of the shield design codes as such, but the practical results from the combined application of massive shield codes and void streaming predictions to complicated problems give information about the true degree of conservatism present.

  9. Determination of 93Zr in medium and low level radioactive wastes from Brazilian nuclear power plants

    International Nuclear Information System (INIS)

    Oliveira, Thiago C.; Oliveira, Arno H.

    2015-01-01

    The majority of long-lived radionuclides produced in the nuclear power plants can be regarded as difficult-to-measure radionuclides (RDM), hence chemical separation is necessary before the nuclear measurement of them. The zirconium isotope 93 Zr is a long-lived pure β-particle-emitting radionuclide produced from 235 U fission and from neutron activation of the stable isotope 92 Zr and thus occurring as one of the radionuclides found in nuclear reactors. Due to its long half-life, 93 Zr is one of the radionuclides of interest for the performance of assessment studies of waste storage or disposal. Two different methodologies based on extractive resins and LSC and ICP-MS techniques that enables the 93 Zr determination in medium (ILW) and low level (LLW) radioactive wastes samples from Brazilian nuclear power plants has been developed in our laboratory. Analyzing real samples 65% and 75% chemical yields for 93 Zr recovery were achieved for ICP-MS and LSC techniques, respectively. The detection limits were 0.045 μg.L -1 for ICP-MS and 0.05 Bq.L -1 for LSC techniques. (author)

  10. Return to learn: Transitioning to school and through ascending levels of academic support for students following a concussion.

    Science.gov (United States)

    McAvoy, Karen; Eagan-Johnson, Brenda; Halstead, Mark

    2018-01-01

    The purpose of this article is to familiarize healthcare providers and parents with educational language, laws, and processes as they relate to a comprehensive ascending level of academic supports as it pertains to promoting a smooth and supported transition to school following a concussion. Returning to learn (RTL) following a concussion is of parallel importance to returning to sport (RTS). A successful RTL is a critical part of concussion management. Many RTL articles advise healthcare providers and parents to request formalized educational supports, also known as Tier 2 or Tier 3 services, for children with concussion as they return to school. Premature requests for formal (Tier 2 or 3) educational services, rather than allowing for immediate informal educational supports (known as Tier 1), can actually delay academic supports and have the potential to cause adversarial relationships between parents and schools. Additionally, this practice contradicts current research demonstrating the need for fast, flexible, temporary academic supports within the first month post-injury. Allowing school districts to direct the application of existing ascending levels of educational support for students with concussion as they return to school can promote robust and positive outcomes.

  11. Determination of the Level of Influence of Various Factors on the Reliability of Power System

    Directory of Open Access Journals (Sweden)

    Victor Popescu

    2014-09-01

    Full Text Available Consumers supply with qualitative electric power is one of the priority requirements imposed to power systems. Currently, in electricity networks take place a number of planned and unplanned disconnections, which interrupt the power and affect consumers, causing economic damage. To ensure the quality of power supply it is essential to know the factors that influence the reliability of power systems, which have a visible impact on the variation of reliability of equipment installed in power systems. This paper is devoted to problems of calculation and analysis of power systems reliability and estimation of the impact of various factors that influence the supply of consumers.

  12. Impact of a coal fired power plant on 226Ra activity level in sea water

    International Nuclear Information System (INIS)

    Marovic, G.; Sencar, J.

    1999-01-01

    The paper deals with radioactivity contamination originating from a coal fired power plant which, due to its location, may present a remarkable environmental problem. The plant is situated in a bay of the Adriatic close to the densely populated area with highly developed touristic activity. Its operation may cause significant damage to rich marine ecosystem characteristic for this part of the Croatian Adriatic as well as endanger urban and touristic developmental prospects of the area. Investigations of coal used in regular plant operation and of solid incombustible ash and slag showed increased natural radioactivity levels which may cause general environmental contamination of the bay as well as contamination of the marine environment of this part of the Croatian Adriatic

  13. Muscle dysmorphia in elite-level power lifters and bodybuilders: a test of differences within a conceptual model.

    Science.gov (United States)

    Lantz, Christopher D; Rhea, Deborah J; Cornelius, Allen E

    2002-11-01

    The purpose of this study was to determine if associated characteristics of muscle dysmorphia (MD) were different between elite-level competitive bodybuilders and power lifters. Elite-level competitive bodybuilders (n = 100) and power lifters (n = 68) completed the muscle dysmorphia inventory (MDI) at the time of or immediately before competition. A 2 x 6 (group x MDI subscales) multivariate analysis of variance indicated that bodybuilders were significantly more likely to report body size-symmetry concerns (F(1, 167) = 10.31, p < 0.001), physique protection (F(1, 167) = 10.27, p < 0.001), dietary behavior (F(1, 167) = 28.38, p < 0.001), and pharmacological use (F(1, 167) = 19.64, p < 0.001) than were power lifters. These results suggest that elite-level bodybuilders are significantly more likely to engage in characteristics associated with MD than are elite-level power lifters.

  14. Adaptative control with non-minimum phase system. Application to level control in PWR power plant steam generator

    International Nuclear Information System (INIS)

    Bihoreau, C.

    1981-03-01

    This thesis presents the proposal for a water control level method likely to improve performance, especially at low power. Particular problems are analyzed in detail. Finally, computerized simulations are presented; they confirm the algorithm performance [fr

  15. Power

    DEFF Research Database (Denmark)

    Elmholdt, Claus Westergård; Fogsgaard, Morten

    2016-01-01

    and creativity suggests that when managers give people the opportunity to gain power and explicate that there is reason to be more creative, people will show a boost in creative behaviour. Moreover, this process works best in unstable power hierarchies, which implies that power is treated as a negotiable....... It is thus a central point that power is not necessarily something that breaks down and represses. On the contrary, an explicit focus on the dynamics of power in relation to creativity can be productive for the organisation. Our main focus is to elaborate the implications of this for practice and theory...

  16. Efficiency improvement of transport service by trolley buses based on the levels of their power demand

    Directory of Open Access Journals (Sweden)

    V. V. Aulin

    2014-12-01

    Full Text Available Purpose. Use efficiency improvement of trolley buses in passenger traffic based on power levels of electric energy input and terms adjustment of their maintenance. Methodology. In order to achieve this goal conformance of electric energy input by trolleybus to the transported amount of passengers taking into account characteristics of the route is offered to establish. The major indicators of the trolleybus operation are: speed of a race on lines, number of tractive motor firing, voltage and amperage in the network that were taken with accountants from a dashboard. Research results were tabulated and recorded with DVR. Along with the study of power consumption of electric energy input by a trolleybus passenger count was carried out too. Findings. The directly proportional dependence between the level of energy consumption by a trolleybus and the number of passengers for constant performance route was determined. Originality. As the criteria for evaluating the effectiveness of the trolleybus operation on the route is proposed to use the ratio between electricity consumption and number of passengers for these characteristics of the route. This is confirmed experimentally. The obtained formulas give the possibility to balance the force work and consequently the volume of energy consumption during the trolleybus movement on the rise and the descent. Practical value. The proposed criterion can be used to adjust the terms of maintenance on the individual program, that means individual maintenance (IM. Type of work performed at the IM should be determined on the basis of diagnostic data of the vehicle (V. The principles of IM were formulated: 1 the primary task is planned and preventative strategy to identify and eliminate troubleshooting and technical actions; 2 operational control of the vehicle (V technical condition on the basis of prediction of its state using the proposed criteria, that takes into account the dependence of power consumption to

  17. Power penalties for multi-level PAM modulation formats at arbitrary bit error rates

    Science.gov (United States)

    Kaliteevskiy, Nikolay A.; Wood, William A.; Downie, John D.; Hurley, Jason; Sterlingov, Petr

    2016-03-01

    There is considerable interest in combining multi-level pulsed amplitude modulation formats (PAM-L) and forward error correction (FEC) in next-generation, short-range optical communications links for increased capacity. In this paper we derive new formulas for the optical power penalties due to modulation format complexity relative to PAM-2 and due to inter-symbol interference (ISI). We show that these penalties depend on the required system bit-error rate (BER) and that the conventional formulas overestimate link penalties. Our corrections to the standard formulas are very small at conventional BER levels (typically 1×10-12) but become significant at the higher BER levels enabled by FEC technology, especially for signal distortions due to ISI. The standard formula for format complexity, P = 10log(L-1), is shown to overestimate the actual penalty for PAM-4 and PAM-8 by approximately 0.1 and 0.25 dB respectively at 1×10-3 BER. Then we extend the well-known PAM-2 ISI penalty estimation formula from the IEEE 802.3 standard 10G link modeling spreadsheet to the large BER case and generalize it for arbitrary PAM-L formats. To demonstrate and verify the BER dependence of the ISI penalty, a set of PAM-2 experiments and Monte-Carlo modeling simulations are reported. The experimental results and simulations confirm that the conventional formulas can significantly overestimate ISI penalties at relatively high BER levels. In the experiments, overestimates up to 2 dB are observed at 1×10-3 BER.

  18. Telomere length in children environmentally exposed to low-to-moderate levels of lead

    International Nuclear Information System (INIS)

    Pawlas, Natalia; Płachetka, Anna; Kozłowska, Agnieszka; Broberg, Karin; Kasperczyk, Sławomir

    2015-01-01

    Shorter relative telomere length in peripheral blood is a risk marker for some types of cancers and cardiovascular diseases. Several environmental hazards appear to shorten telomeres, and this shortening may predispose individuals to disease. The aim of the present cross-sectional study was to assess the effect of environmental exposure to lead on relative telomere length (rTL) in children. A cohort of 99 8-year-old children was enrolled from 2007–2010. Blood lead concentrations (B-Pb) were measured by graphite furnace atomic absorption spectrometry, and blood rTL was measured by quantitative PCR. The geometric mean of B-Pb was 3.28 μg/dl (range: 0.90–14.2), and the geometric mean of rTL was 1.08 (range: 0.49–2.09). B-Pb was significantly inversely associated with rTL in the children (r S = − 0.25, p = 0.013; in further analyses both log-transformed-univariate regression analysis β = − 0.13, p = 0.026, and R 2 adj 4%; and β = − 0.12, p = 0.056 when adjusting for mothers' smoking during pregnancy, Apgar score, mother's and father's ages at delivery, sex and mother's education, R 2 adj 12%, p = 0.011). The effect of lead remained significant in children without prenatal tobacco exposure (N = 87, r S = − 0.24, p = 0.024; in further analyses, β = − 0.13, p = 0.029, and R 2 adj 4%). rTL was not affected by sex, the concentrations of other elements in the blood (i.e., cadmium and selenium concentrations), or oxidative injury parameters (total antioxidant status, 8-hydroxydeoxyguanosine and thiobarbituric acid-reactive substances). Lead exposure in childhood appears to be associated with shorter telomeres, which might contribute to diseases, such as cardiovascular disease. The inverse association between blood lead level and the telomeres in children emphasizes the importance of further reducing lead levels in the environment. - Highlights: • This cross-sectional study analyzes the association between environmental lead exposure

  19. Telomere length in children environmentally exposed to low-to-moderate levels of lead

    Energy Technology Data Exchange (ETDEWEB)

    Pawlas, Natalia, E-mail: n-pawlas@wp.pl [Institute of Occupational Medicine and Environmental Health, PL 41-200 Sosnowiec (Poland); Płachetka, Anna [Department of Animal Physiology and Ecotoxicology, University of Silesia, Bankowa str. 9, 40-007 Katowice (Poland); Kozłowska, Agnieszka [Institute of Occupational Medicine and Environmental Health, PL 41-200 Sosnowiec (Poland); Broberg, Karin [Institute of Environmental Medicine, Unit of Metals & Health, Box 210, SE-171 77 Stockholm (Sweden); Kasperczyk, Sławomir [Department of Biochemistry, Medical University of Silesia, Katowice, SMDZ in Zabrze, 41-808 Zabrze (Poland)

    2015-09-01

    Shorter relative telomere length in peripheral blood is a risk marker for some types of cancers and cardiovascular diseases. Several environmental hazards appear to shorten telomeres, and this shortening may predispose individuals to disease. The aim of the present cross-sectional study was to assess the effect of environmental exposure to lead on relative telomere length (rTL) in children. A cohort of 99 8-year-old children was enrolled from 2007–2010. Blood lead concentrations (B-Pb) were measured by graphite furnace atomic absorption spectrometry, and blood rTL was measured by quantitative PCR. The geometric mean of B-Pb was 3.28 μg/dl (range: 0.90–14.2), and the geometric mean of rTL was 1.08 (range: 0.49–2.09). B-Pb was significantly inversely associated with rTL in the children (r{sub S} = − 0.25, p = 0.013; in further analyses both log-transformed-univariate regression analysis β = − 0.13, p = 0.026, and R{sup 2}adj 4%; and β = − 0.12, p = 0.056 when adjusting for mothers' smoking during pregnancy, Apgar score, mother's and father's ages at delivery, sex and mother's education, R{sup 2}adj 12%, p = 0.011). The effect of lead remained significant in children without prenatal tobacco exposure (N = 87, r{sub S} = − 0.24, p = 0.024; in further analyses, β = − 0.13, p = 0.029, and R{sup 2}adj 4%). rTL was not affected by sex, the concentrations of other elements in the blood (i.e., cadmium and selenium concentrations), or oxidative injury parameters (total antioxidant status, 8-hydroxydeoxyguanosine and thiobarbituric acid-reactive substances). Lead exposure in childhood appears to be associated with shorter telomeres, which might contribute to diseases, such as cardiovascular disease. The inverse association between blood lead level and the telomeres in children emphasizes the importance of further reducing lead levels in the environment. - Highlights: • This cross-sectional study analyzes the association between

  20. Experimental analysis of flexibility change with different levels of power reduction by demand response activation on thermostat controlled loads

    DEFF Research Database (Denmark)

    Lakshmanan, Venkatachalam; Marinelli, Mattia; Hu, Junjie

    2017-01-01

    This paper studies the flexibility available with thermostatically controlled loads (TCLs) to provide power system services by demand response (DR) activation. Although the DR activation on TCLs can provide power system ancillary services, it is important to know how long such services can...... be provided for when different levels of power reduction are imposed. The flexibility change with different levels of power reduction is tested experimentally with domestic fridges used by real customers with unknown user interaction. The investigation quantifies the flexibility of household fridges...... and the impact of DR activation in terms of deviation in the average temperature. The maximum possible power reduction with the cluster of refrigerators is 67% and the available flexibility with the cluster of refrigerators is 10%. The resulting deviation in the average temperature is 14%....

  1. Clearance of very low level radioactive waste in spanish nuclear power plants

    International Nuclear Information System (INIS)

    Alvarez Mir, F.

    2001-01-01

    According to present Spanish legislation a radioactive waste is defined as any material or waste product, without any possible planned use, that contains or is contaminated with radionuclides in concentrations or activity levels higher than those established by the Regulatory Authorities. Legally, this situation allows to develop a conventional management of very low level radioactive waste, by checking the negligibility of their radiological impact, and thus obtaining the corresponding Authorization to treat them as conventional waste. This presentation describes the clearance project of contaminated oils from spanish nuclear power plants. The on-site management includes: -) preliminary settling, centrifugation and filtration; -) oil purification; and -) radiological characterization. The off-site management includes the following operations: -) transportation to the facility where treatment is developed (dilution); -) temporary storage (decay); -) transportation to the place where final management is carried out; -) oil burning (dilution); and management of ashes and other combustion products. An annual amount of 70 m 3 /year (63 MBq) of very low contaminated oil with a specific concentration of 1 Bq/g could be disposed off. (A.C.)

  2. Output feedback dissipation control for the power-level of modular high-temperature gas-cooled reactors

    International Nuclear Information System (INIS)

    Dong, Z.

    2011-01-01

    Because of its strong inherent safety features and the high outlet temperature, the modular high temperature gas-cooled nuclear reactor (MHTGR) is the chosen technology for a new generation of nuclear power plants. Such power plants are being considered for industrial applications with a wide range of power levels, thus power-level regulation is very important for their efficient and stable operation. Exploiting the large scale asymptotic closed-loop stability provided by nonlinear controllers, a nonlinear power-level regulator is presented in this paper that is based upon both the techniques of feedback dissipation and well-established backstepping. The virtue of this control strategy, i.e., the ability of globally asymptotic stabilization, is that it takes advantage of the inherent zero-state detectability property of the MHTGR dynamics. Moreover, this newly built power-level regulator is also robust towards modeling uncertainty in the control rod dynamics. If modeling uncertainty of the control rod dynamics is small enough to be omitted, then this control law can be simplified to a classical proportional feedback controller. The comparison of the control performance between the newly-built power controller and the simplified controller is also given through numerical study and theoretical analysis. (author)

  3. Output Feedback Dissipation Control for the Power-Level of Modular High-Temperature Gas-Cooled Reactors

    Directory of Open Access Journals (Sweden)

    Zhe Dong

    2011-11-01

    Full Text Available Because of its strong inherent safety features and the high outlet temperature, the modular high temperature gas-cooled nuclear reactor (MHTGR is the chosen technology for a new generation of nuclear power plants. Such power plants are being considered for industrial applications with a wide range of power levels, thus power-level regulation is very important for their efficient and stable operation. Exploiting the large scale asymptotic closed-loop stability provided by nonlinear controllers, a nonlinear power-level regulator is presented in this paper that is based upon both the techniques of feedback dissipation and well-established backstepping. The virtue of this control strategy, i.e., the ability of globally asymptotic stabilization, is that it takes advantage of the inherent zero-state detectability property of the MHTGR dynamics. Moreover, this newly built power-level regulator is also robust towards modeling uncertainty in the control rod dynamics. If modeling uncertainty of the control rod dynamics is small enough to be omitted, then this control law can be simplified to a classical proportional feedback controller. The comparison of the control performance between the newly-built power controller and the simplified controller is also given through numerical study and theoretical analysis.

  4. Dose estimation for nuclear power plant 4 accident in Taiwan at Fukushima nuclear meltdown emission level

    International Nuclear Information System (INIS)

    Tang, Mei-Ling; Tsuang, Ben-Jei; Kuo, Pei-Hsuan

    2016-01-01

    An advanced Gaussian trajectory dispersion model is used to evaluate the evacuation zone due to a nuclear meltdown at the Nuclear Power Plant 4 (NPP4) in Taiwan, with the same emission level as that occurred at Fukushima nuclear meltdown (FNM) in 2011. Our study demonstrates that a FNM emission level would pollute 9% of the island's land area with annual effective dose ≥50 mSv using the meteorological data on 11 March 2011 in Taiwan. This high dose area is also called permanent evacuation zone (denoted as PEZ). The PEZ as well as the emergency-planning zone (EPZ) are found to be sensitive to meteorological conditions on the event. In a sunny day under the dominated NE wind conditions, the EPZ can be as far as 100 km with the first 7-day dose ≥20 mSv. Three hundred sixty-five daily events using the meteorological data from 11 March 2011 to 9 March 2012 are evaluated. It is found that the mean land area of Taiwan in becoming the PEZ is 11%. Especially, the probabilities of the northern counties/cities (Keelung, New Taipei, Taipei, Taoyuan, Hsinchu City, Hsinchu County and Ilan County) to be PEZs are high, ranging from 15% in Ilan County to 51% in Keelung City. Note that the total population of the above cities/counties is as high as 10 million people. Moreover, the western valleys of the Central Mountain Range are also found to be probable being PEZs, where all of the reservoirs in western Taiwan are located. For example, the probability can be as high as 3% in the far southern-most tip of Taiwan Island in Pingtung County. This shows that the entire populations in western Taiwan can be at risk due to the shortage of clean water sources under an event at FNM emission level, especially during the NE monsoon period. - Highlights: • An advanced Gaussian-type trajectory model to evaluate the evacuation zone at Nuclear Power Plant 4 in Taiwan. • Mean land area of Taiwan in becoming the permanent evacuation zone is 11%. • The probabilities of the northern

  5. Synthesis of Axial Power Distribution Using 5-Level Ex-core Detector in a Core Protection System

    International Nuclear Information System (INIS)

    Koo, Bon-Seung; Lee, Chung-Chan; Zee, Sung-Quun

    2007-01-01

    In ABB-CE digital plants, Core Protection Calculator System (CPCS) is used for a core protection based on several online measured system parameters including 3- level safety grade ex-core detector signals. The CPCS provides four independent channels for the departure from a nucleate boiling ratio (DNBR) and local power density (LPD) trip signals to the reactor protection system. Each channel consists of a core protection calculator (CPC) and a control element assembly calculator (CEAC). The cubic spline synthesis technique has been used in online calculations of the core axial power distributions using 3-level ex-core detector signals in CPC. The pre-determined cubic spline function sets are used depending on the characteristics of the ex-core detector responses. But this method shows large power distribution errors for the extremely skewed axial shapes due to restrictive function sets and an incorrect SAM value. Especially thus situation is worse at a higher burnup. To solve these problems, the cubic spline function sets are improved and it is demonstrated that the axial power shapes can be synthesized more accurately with the new function sets than those of a conventional CPC. In this paper, synthesis of an axial power distribution using a 5-level ex-core detector is described and the axial power distributions are compared between 3-level and 5-level ex-core detector systems

  6. Dose estimation for nuclear power plant 4 accident in Taiwan at Fukushima nuclear meltdown emission level.

    Science.gov (United States)

    Tang, Mei-Ling; Tsuang, Ben-Jei; Kuo, Pei-Hsuan

    2016-05-01

    An advanced Gaussian trajectory dispersion model is used to evaluate the evacuation zone due to a nuclear meltdown at the Nuclear Power Plant 4 (NPP4) in Taiwan, with the same emission level as that occurred at Fukushima nuclear meltdown (FNM) in 2011. Our study demonstrates that a FNM emission level would pollute 9% of the island's land area with annual effective dose ≥50 mSv using the meteorological data on 11 March 2011 in Taiwan. This high dose area is also called permanent evacuation zone (denoted as PEZ). The PEZ as well as the emergency-planning zone (EPZ) are found to be sensitive to meteorological conditions on the event. In a sunny day under the dominated NE wind conditions, the EPZ can be as far as 100 km with the first 7-day dose ≥20 mSv. Three hundred sixty-five daily events using the meteorological data from 11 March 2011 to 9 March 2012 are evaluated. It is found that the mean land area of Taiwan in becoming the PEZ is 11%. Especially, the probabilities of the northern counties/cities (Keelung, New Taipei, Taipei, Taoyuan, Hsinchu City, Hsinchu County and Ilan County) to be PEZs are high, ranging from 15% in Ilan County to 51% in Keelung City. Note that the total population of the above cities/counties is as high as 10 million people. Moreover, the western valleys of the Central Mountain Range are also found to be probable being PEZs, where all of the reservoirs in western Taiwan are located. For example, the probability can be as high as 3% in the far southern-most tip of Taiwan Island in Pingtung County. This shows that the entire populations in western Taiwan can be at risk due to the shortage of clean water sources under an event at FNM emission level, especially during the NE monsoon period. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  7. A geographically resolved method to estimate levelized power plant costs with environmental externalities

    International Nuclear Information System (INIS)

    Rhodes, Joshua D.; King, Carey; Gulen, Gürcan; Olmstead, Sheila M.; Dyer, James S.; Hebner, Robert E.; Beach, Fred C.; Edgar, Thomas F.; Webber, Michael E.

    2017-01-01

    In this analysis we developed and applied a geographically-resolved method to calculate the Levelized Cost of Electricity (LCOE) of new power plants on a county-by-county basis while including estimates of some environmental externalities. We calculated the LCOE for each county of the contiguous United States for 12 power plant technologies. The minimum LCOE option for each county varies based on local conditions, capital and fuel costs, environmental externalities, and resource availability. We considered ten scenarios that vary input assumptions. We present the results in a map format to facilitate comparisons by fuel, technology, and location. For our reference analysis, which includes a cost of $62/tCO_2 for CO_2 emissions natural gas combined cycle, wind, and nuclear are most often the lowest-LCOE option. While the average cost increases when internalizing the environmental externalities (carbon and air pollutants) is small for some technologies, the local cost differences are as high as $0.62/kWh for coal (under our reference analysis). These results display format, and online tools could serve as an educational tool for stakeholders when considering which technologies might or might not be a good fit for a given locality subject to system integration considerations. - Highlights: • We propose a method to add externalities to LCOE. • We present the least cost technology for every county in the US. • The cheapest technology depends on many characteristics of that locale. • We present online tools for users to change our assumptions. • Our tools are useful in discussing the impact of policy on the cost of electricity.

  8. Deconstructing the power resistance relationship for squats: A joint-level analysis.

    Science.gov (United States)

    Farris, D J; Lichtwark, G A; Brown, N A T; Cresswell, A G

    2016-07-01

    Generating high leg power outputs is important for executing rapid movements. Squats are commonly used to increase leg strength and power. Therefore, it is useful to understand factors affecting power output in squatting. We aimed to deconstruct the mechanisms behind why power is maximized at certain resistances in squatting. Ten male rowers (age = 20 ± 2.2 years; height = 1.82 ± 0.03 m; mass = 86 ± 11 kg) performed maximal power squats with resistances ranging from body weight to 80% of their one repetition maximum (1RM). Three-dimensional kinematics was combined with ground reaction force (GRF) data in an inverse dynamics analysis to calculate leg joint moments and powers. System center of mass (COM) velocity and power were computed from GRF data. COM power was maximized across a range of resistances from 40% to 60% 1RM. This range was identified because a trade-off in hip and knee joint powers existed across this range, with maximal knee joint power occurring at 40% 1RM and maximal hip joint power at 60% 1RM. A non-linear system force-velocity relationship was observed that dictated large reductions in COM power below 20% 1RM and above 60% 1RM. These reductions were due to constraints on the control of the movement. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Natural radionuclides near a coal-fired power station. [/sup 210/Po and /sup 210/Pb levels in cattle livers

    Energy Technology Data Exchange (ETDEWEB)

    Smith-Briggs, J L; Crick, M J [National Radiological Protection Board, Harwell (UK)

    1982-11-01

    Previous measurements have shown enhanced levels of /sup 210/Po and /sup 210/Pb from fly ash deposited in the environment around old coal-fired power stations. Preliminary results are presented for levels of /sup 210/Po and /sup 210/Pb in liver samples from cattle which had grazed for two to three years in a field adjacent to a modern power station. No significant difference in the levels of these natural radionuclides was found compared to liver samples obtained from cattle in a control area.

  10. An Artificial Neural Network Compensated Output Feedback Power-Level Control for Modular High Temperature Gas-Cooled Reactors

    Directory of Open Access Journals (Sweden)

    Zhe Dong

    2014-02-01

    Full Text Available Small modular reactors (SMRs could be beneficial in providing electricity power safely and also be viable for applications such as seawater desalination and heat production. Due to its inherent safety features, the modular high temperature gas-cooled reactor (MHTGR has been seen as one of the best candidates for building SMR-based nuclear power plants. Since the MHTGR dynamics display high nonlinearity and parameter uncertainty, it is necessary to develop a nonlinear adaptive power-level control law which is not only beneficial to the safe, stable, efficient and autonomous operation of the MHTGR, but also easy to implement practically. In this paper, based on the concept of shifted-ectropy and the physically-based control design approach, it is proved theoretically that the simple proportional-differential (PD output-feedback power-level control can provide asymptotic closed-loop stability. Then, based on the strong approximation capability of the multi-layer perceptron (MLP artificial neural network (ANN, a compensator is established to suppress the negative influence caused by system parameter uncertainty. It is also proved that the MLP-compensated PD power-level control law constituted by an experientially-tuned PD regulator and this MLP-based compensator can guarantee bounded closed-loop stability. Numerical simulation results not only verify the theoretical results, but also illustrate the high performance of this MLP-compensated PD power-level controller in suppressing the oscillation of process variables caused by system parameter uncertainty.

  11. Impacts from a fossil fuel power plant on ozone levels in Memphis, Tennessee

    International Nuclear Information System (INIS)

    Mueller, S.F.; Bailey, E.M.

    1998-01-01

    The Tennessee Valley Authority (TVA) Allen power plant is located on the Mississippi River in the southwest corner of Memphis, Tennessee. Allen has three coal-fired cyclone boilers with a rated capacity of 272 MW each. It is a Phase 2 plant under Title IV of the Clean Air Act and is the largest single source of NO x in the Memphis area. TVA plans to reduce Allen NOx emissions through a combination of burning low-sulfur coal (which has the benefit of reducing NO x emissions while also reducing SO 2 emissions) and installing gas re-burn technology. A modeling study using the SAI, Inc., UAM-V photochemical model was conducted to examine the potential impacts of NO x reductions on ozone levels in the Memphis area. A series of four model simulations were made in which different Allen emissions scenarios were examined. The focus period of the photochemical modeling was 11--14 July 1995 when measurements in and near Memphis indicated peak hourly ozone levels of 135--140 ppb. This analysis primarily examined computed impacts within 50 km of Memphis. Allen was computed to contribute as much as 20--30 ppb to ground ozone levels 20-50 km downwind using its NO x emission rate before Title IV compliance. After compliance it was computed to contribute only about 10--20 ppb. At the same time, maximum daily ozone reductions due to Allen NO x titration of ozone were between 30 and 60 ppb. These benefits will be reduced by 30--50% after Title IV compliance, and are expected to occur within 30 km of the plant. More model grid cells indicated dis-benefits (net ground-level ozone increases) than benefits on three of the four episode days using the Title IV compliance emission rate. Significant ozone dis-benefits were expected because of the well-documented NO titration of ozone within plumes having a high ratio of NO to volatile organic compounds

  12. Low level measurements of natural radionuclides in soil samples around a coal-fired power plant

    International Nuclear Information System (INIS)

    Rosner, G.; Bunzl, K.; Hoetzl, H.; Winkler, R.

    1984-01-01

    To detect a possible contribution of airborne radioactivity from stack effluents to the soil radioactivity, several radionuclides in the soil around a coal-fired power plant have been determined. A plant situated in a rural region of Bavaria was selected to minimize contributions from other civilisatory sources. The soil sampling network consisted of 5 concentric circles with diameters between 0.4 and 5.2 km around the plant, 16 sampling points being distributed regularly on each circle. Radiochemical analysis techniques for 210 Pb and 210 Po in soil samples of several grams has to be developed. They include a wet dissolution procedure, simultaneous precipitation of lead and polonium as the sulfides, purification via lead sulfate, counting of the lead as the chromate in a low-level beta counter and alpha spectrometric determination of the 210 Po in a gridded ionization chamber. The 238 U, 226 Ra, 232 Th and 40 K were counted by low level gamma spectrometry. Specific activities found were in the range of 0.7 to 2.0 pCi g -1 for 210 Pb and 0.3 to 1.6 pCi g -1 for 226 Ra. The distribution patterns of 210 Po and 210 Pb around the plant were found to be similar. They were different, however, from that of 226 Ra. The highest 210 Pb/ 226 Ra activity ratio was 3.9 at a distance of 0.76 km SSE from the plant. Nevertheless, the evidence is not considered to be sufficient to attribute these observations unambiguously to plant release. (orig.)

  13. Low level measurements of natural radionuclides in soil samples around a coal-fired power plant

    Energy Technology Data Exchange (ETDEWEB)

    Rosner, G.; Bunzl, K.; Hoetzl, H.; Winkler, R. (Gesellschaft fuer Strahlen- und Umweltforschung m.b.H. Muenchen, Neuherberg (Germany, F.R.). Inst. fuer Strahlenschutz)

    1984-06-15

    To detect a possible contribution of airborne radioactivity from stack effluents to the soil radioactivity, several radionuclides in the soil around a coal-fired power plant have been determined. A plant situated in a rural region of Bavaria was selected to minimize contributions from other civilisatory sources. The soil sampling network consisted of 5 concentric circles with diameters between 0.4 and 5.2 km around the plant, 16 sampling points being distributed regularly on each circle. Radiochemical analysis techniques for /sup 210/Pb and /sup 210/Po in soil samples of several grams has to be developed. They include a wet dissolution procedure, simultaneous precipitation of lead and polonium as the sulfides, purification via lead sulfate, counting of the lead as the chromate in a low-level beta counter and alpha spectrometric determination of the /sup 210/Po in a gridded ionization chamber. The /sup 238/U, /sup 226/Ra, /sup 232/Th and /sup 40/K were counted by low level gamma spectrometry. Specific activities found were in the range of 0.7 to 2.0 pCi g/sup -1/ for /sup 210/Pb and 0.3 to 1.6 pCi g/sup -1/ for /sup 226/Ra. The distribution patterns of /sup 210/Po and /sup 210/Pb around the plant were found to be similar. They were different, however, from that of /sup 226/Ra. The highest /sup 210/Pb//sup 226/Ra activity ratio was 3.9 at a distance of 0.76 km SSE from the plant. Nevertheless, the evidence is not considered to be sufficient to attribute these observations unambiguously to plant release.

  14. Levelling the playing field? The influence of national wind power planning instruments on conflicts of interests in a Swedish county

    International Nuclear Information System (INIS)

    Bergek, Anna

    2010-01-01

    Slow and complicated wind power planning and permitting procedures have been a large obstacle for wind power diffusion in Sweden and other countries. This paper complements previous siting-oriented literature with a planning perspective on these problems. The focus is two national planning instruments implemented in Sweden in the early 2000s: a national planning target and an appointment of areas of national interest for wind power. The paper identifies different types of conflicts of interest related to wind power - in addition to the conflict between wind power as a national public interest and various local private interests - and analyses the impact of the national planning instruments on the handling of these conflicts in the land-use planning process in the County of Ostergoetland. The analysis shows that the planning target actually made local planning officials even more inclined to treat wind power as a private rather than a public interest and that the method used to identify areas of national interest of wind power forced wind power to compete with the combined strengths of all other public interest. The planning instruments thus left wind power to fight an uphill battle rather than to meet other interests face-to-face on a level playing field.

  15. Classification of low-level radioactive wastes from nuclear power plants

    International Nuclear Information System (INIS)

    Stanford, R.E.L.

    1984-01-01

    The NRC regulation, 10 CFR Part 61, establishes three classes of wastes designated A, B, and C based on listed concentrations of specific nuclides. The NRC Branch Technical Position (BTP) relative to the required compliance program focused on extensive waste stream sampling and analysis as a means of compliance. To meet the above regulatory requirements, an engineering analysis approach for quantifying the concentrations and amounts of radionuclides of classification concern was developed as an alternative to an extensive and difficult waste sampling and analysis program. Essentially this methodology involves a material balance of radionuclides which for the most part originate in the reactor core and are transported to the waste streams by reactor coolants and whose concentration in the coolant is primarily a function of fuel performance. The use of scaling factors between readily measured key radionuclides and others required for classification have been published in Report AIF/NESP-027 entitled, Methodologies for Classification of Low-Level Radioactive Wastes from Nuclear Power Plants. Since then data from about 1000 samples on nuclide concentrations in various reactor waste streams from 65 units at 40 sites was collated, analyzed and evaluated to confirm the calculational methodology in AIF/NESP-027. In summary, the approach and results of the engineering analysis methodology were validated

  16. Electric power generated by fossil fuels: Impact and environmental administration at global and local level

    International Nuclear Information System (INIS)

    Moscarella, John Paul

    1999-01-01

    An analysis is presented on the derived environmental implications of the current and future structure in the electric power market at international level. The reduced prices of the hydrocarbons determine that the fossil electricity is imposed on other generation forms, that which generates serious challenges to the companies and the governments as regards control and handling of gases emissions. By means of a comparative sample of eight electric companies of developed countries and in development, the tendencies are evaluated in the local and regional markets, as well as the environmental effects of different generating systems of electricity. The mechanism of well-known market is analyzed as activities implemented jointly (AIJ) referred to activities to be implemented jointly to combat the greenhouse gases effect. It concludes that in the short and medium term the conditions of the market will continue favoring the generation of fossil energy, reason why they should strengthen mechanisms of the climatic change control and to impel toward the long term the development of renewable and alternative energy

  17. Costs of reducing water use of concentrating solar power to sustainable levels: Scenarios for North Africa

    International Nuclear Information System (INIS)

    Damerau, Kerstin; Williges, Keith; Patt, Anthony G.; Gauche, Paul

    2011-01-01

    Concentrating solar power (CSP) has the potential to become a leading sustainable energy technology for the European electricity system. In order to reach a substantial share in the energy mix, European investment in CSP appears most profitable in North Africa, where solar potential is significantly higher than in southern Europe. As well as sufficient solar irradiance, however, the majority of today's CSP plants also require a considerable amount of water, primarily for cooling purposes. In this paper we examine water usage associated with CSP in North Africa, and the cost penalties associated with technologies that could reduce those needs. We inspect four representative sites to compare the ecological and economical drawbacks from conventional and alternative cooling systems, depending on the local environment, and including an outlook with climate change to the mid-century. Scaling our results up to a regional level indicates that the use of wet cooling technologies would likely be unsustainable. Dry cooling systems, as well as sourcing of alternative water supplies, would allow for sustainable operation. Their cost penalty would be minor compared to the variance in CSP costs due to different average solar irradiance values. - Highlights: → Scaling up CSP with wet cooling from ground water will be unsustainable in North Africa. → Desalination and alternative cooling systems can assure a sustainable water supply. → On large-scale, the cost penalties of alternative cooling technologies appear minor.

  18. Model for the techno-economic analysis of common work of wind power and CCGT power plant to offer constant level of power in the electricity market

    Directory of Open Access Journals (Sweden)

    Tomsic Z.

    2017-01-01

    For calculation purposes, the following parameters are necessary to know in order to be able to economically evaluate changes in the start-up process: ramp up and down rate, time of start time reduction, fuel mass flow during start, electricity production during start, variable cost of start-up process, cost and charges for life time consumption for each start and start type, remuneration during start up time regarding expected or unexpected starts, the cost and revenues for balancing energy (important when participating in electricity market, and the cost or revenues for CO2-certificates. Main motivation for this analysis is to investigate possibilities to participate on power exchanges by offering continues guarantied power from wind plants by backing-up them with CCGT power plant.

  19. Thermal Equilibrium Dynamic Control Based on DPWM Dual-Mode Modulation of High Power NPC Three-Level Inverter

    Directory of Open Access Journals (Sweden)

    Shi-Zhou Xu

    2016-01-01

    Full Text Available In some special applications of NPC three-level inverters, such as mine hoist, there exist special conditions of overloading during the whole hoisting process and large overload in starting stage, during which the power-loss calculation of power devices and thermal control are important factors affecting the thermal stability of inverters. The principles of SVPWM and DPWM were described in this paper firstly, based on which the dynamic power losses of the two modulations of hoist in single period were calculated. Secondly, a thermal equilibrium dynamic control based on DPMW dual-mode modulation was proposed, which can switch the modulation dynamically according to the change of dynamic power loss to realize dynamic control of power loss and thermal equilibrium of inverter. Finally, simulation and experiment prove the effectiveness of the proposed strategy.

  20. Optimization of E-DCH channel power ratios to maximize link level efficiency

    DEFF Research Database (Denmark)

    Zarco, Carlos Ruben Delgado; Malone, Jaime Tito; Wigard, Jeroen

    2006-01-01

    For the WCDMA/HSUPA concept, a key to ensuring high spectral efficiency is to correctly adjust the transmission power ratios among the data and control channels. This paper provides optimal values for the power ratio between the Enhanced-Dedicated Physical Data Channel (E-DPDCH) and the Dedicated...... rate (typical values ranging from 8.1 to 9.9 dB) and the RSN target (maintaining or decreasing their value as the target increases). These results show that it is more link efficient to increase the DPCCH transmission power with the bit rate (and the E-DPDCH's by applying the power ratio) than...... to maintain a constant DPCCH transmission power and just increase the EDPDCH to DPCCH power ratio....

  1. Analysis for low and intermediate level radioactive waste disposal of AP1000 nuclear power in China

    International Nuclear Information System (INIS)

    Yang Bin; Ren Li; Hua Wei; Ma Xiaoqiang; Ma Ruoxia; Fang Xianghong

    2014-01-01

    AP1000 nuclear power is adopted in Sanmen Nuclear Power Plant, Zhejiang province and Haiyang Nuclear Power Plant, Shandong province. The filter and resin generated by the operation of nuclear power plants are handled by cement cured process and compression technology in Sanmen Nuclear Power Plant, while they are loaded in polyethylene HIC in Haiyang Nuclear Power Plant. At present, there were not engineering practice for dispose polyethylene HIC in China. The document discusses three disposal options of polyethylene HIC: one is that polyethylene HIC placed in over pack, another is that polyethylene HIC mixed with other drum, the third is that polyethylene HIC placed in disposal unit which is divided into small units. (authors)

  2. Heating power at room and building levels in passive houses and low-energy buildings

    OpenAIRE

    Rinholm, Jonas Myrberg

    2015-01-01

    This master thesis investigates the Norwegian standard for calculating necessary power demand, NS-EN 12831:2003- Varmesystemer i bygninger - Metode for beregning av dimensjonerende effektbehov. In that context, it is also investigated how power demand affects heating systems financially and environmentally, but also in terms of comfort and indoor air quality. Improved energy efficiency are leading to a reduction in the power demand for heating purposes in buildings. However, there are few...

  3. Power distribution, the environment, and public health. A state-level analysis

    International Nuclear Information System (INIS)

    Boyce, James K.; Klemer, Andrew R.; Templet, Paul H.; Willis, Cleve E.

    1999-01-01

    This paper examines relationships among power distribution, the environment, and public health by means of a cross-sectional analysis of the 50 US states. A measure of inter-state variations in power distribution is derived from data on voter participation, tax fairness, Medicaid access, and educational attainment. We develop and estimate a recursive model linking the distribution of power to environmental policy, environmental stress, and public health. The results support the hypothesis that greater power inequality leads to weaker environmental policies, which in turn lead to greater environmental degradation and to adverse public health outcomes

  4. Power distribution, the environment, and public health. A state-level analysis

    Energy Technology Data Exchange (ETDEWEB)

    Boyce, James K. [Department of Economics, University of Massachusetts, Amherst, MA 01003 (United States); Klemer, Andrew R. [Department of Biology, University of Minnesota, Duluth, MN (United States); Templet, Paul H. [Institute of Environmental Studies, Louisiana State University, Baton Rouge, LA (United States); Willis, Cleve E. [Department of Resource Economics, University of Massachusetts, Amherst, MA 01003 (United States)

    1999-04-15

    This paper examines relationships among power distribution, the environment, and public health by means of a cross-sectional analysis of the 50 US states. A measure of inter-state variations in power distribution is derived from data on voter participation, tax fairness, Medicaid access, and educational attainment. We develop and estimate a recursive model linking the distribution of power to environmental policy, environmental stress, and public health. The results support the hypothesis that greater power inequality leads to weaker environmental policies, which in turn lead to greater environmental degradation and to adverse public health outcomes.

  5. Power distribution, the environment, and public health. A state-level analysis

    Energy Technology Data Exchange (ETDEWEB)

    Boyce, James K. [Department of Economics, University of Massachusetts, Amherst, MA 01003 (United States); Klemer, Andrew R. [Department of Biology, University of Minnesota, Duluth, MN (United States); Templet, Paul H. [Institute of Environmental Studies, Louisiana State University, Baton Rouge, LA (United States); Willis, Cleve E. [Department of Resource Economics, University of Massachusetts, Amherst, MA 01003 (United States)

    1999-04-15

    This paper examines relationships among power distribution, the environment, and public health by means of a cross-sectional analysis of the 50 US states. A measure of inter-state variations in power distribution is derived from data on voter participation, tax fairness, Medicaid access, and educational attainment. We develop and estimate a recursive model linking the distribution of power to environmental policy, environmental stress, and public health. The results support the hypothesis that greater power inequality leads to weaker environmental policies, which in turn lead to greater environmental degradation and to adverse public health outcomes

  6. Early Experiences with Node-Level Power Capping on the Cray XC40 Platform

    Energy Technology Data Exchange (ETDEWEB)

    Pedretti, Kevin; Olivier, Stephen Lecler; Ferreira, Kurt Brian; Shipman, Galen; Shu, Wei

    2015-10-01

    Power consumption of extreme-scale supercomputers has become a key performance bottleneck. Yet current practices do not leverage power management opportunities, instead running at ''maximum power''. This is not sustainable. Future systems will need to manage power as a critical resource, directing where it has greatest benefit. Power capping is one mechanism for managing power budgets, however its behavior is not well understood. This paper presents an empirical evaluation of several key HPC workloads running under a power cap on a Cray XC40 system, and provides a comparison of this technique with p-state control, demonstrating the performance differences of each. These results show: 1. Maximum performance requires ensuring the cap is not reached; 2. Performance slowdown under a cap can be attributed to cascading delays which result in unsynchronized performance variability across nodes; and, 3. Due to lag in reaction time, considerable time is spent operating above the set cap. This work provides a timely and much needed comparison of HPC application performance under a power cap and attempts to enable users and system administrators to understand how to best optimize application performance on power-constrained HPC systems.

  7. TECHNICAL AND ECONOMIC EVALUATION OF OPTIMAL VOLTAGE LEVEL FOR THE POWER SUPPLY OF DEEP MINE OPERATING HORIZONS

    OpenAIRE

    Shkrabets, F. P.; Ostapchuk, O. V.; Kozhevnikov, A. V.; Akulov, A. V.

    2015-01-01

    The most perspective option for possible deep mine power supply is the one with the deep input of 35 kV voltage by installing of underground 35kV/6 kV substation. This option is caused by the expected level of electrical loads, provided by mine development, the power consumers’ deep layout (considering the distance from the source to the shaft on the surface and from the shaft to the underground substation chamber) and primary and the most responsible power consumers (blind shaft lifting devi...

  8. Simulation of Standby Efficiency Improvement for a Line Level Control Resonant Converter Based on Solar Power Systems

    Directory of Open Access Journals (Sweden)

    Ming-Tse Kuo

    2015-01-01

    Full Text Available This paper proposes a new scheme to improve the standby efficiency of the high-power half-bridge line level control (LLC resonant converter. This new circuit is applicable to improving the efficiency of the renewable energy generation system in distributed power systems. The main purpose is to achieve high-efficiency solar and wind power and stable output under different load conditions. In comparison with the traditional one, this novel method can improve standby efficiency at standby. The system characteristics of this proposed method have been analyzed through detailed simulations, which prove its feasibility.

  9. A thermoelectric-conversion power supply system using a strontium heat source of high-level radioactive nuclear waste

    International Nuclear Information System (INIS)

    Chikazawa, Yoshitaka

    2011-01-01

    A thermoelectric-conversion power supply system with radioactive strontium in high-level radioactive waste has been proposed. A combination of Alkali Metal Thermo-Electric Conversion (AMTEC) and a strontium fluoride heat source can provide a compact and long-lived power supply system. A heat source design with strontium fluoride pin bundles with Hastelloy cladding and intermediate copper has been proposed. This design has taken heat transportation into consideration, and, in this regard, the feasibility has been confirmed by a three-dimensional thermal analysis using Star-CD code. This power supply system with an electric output of 1 MW can be arranged in a space of 50 m 2 and approximately 1.1 m height and can be operated for 15 years without refueling. This compact and long-lived power supply is suitable for powering sources for remote places and middle-sized ships. From the viewpoint of geological disposal of high-level waste, the proposed power supply system provides a financial base for strontium-cesium partitioning. That is, a combination of minor-actinide recycling and strontium-cesium partitioning can eliminate a large part of decay heat in high-level waste and thus can save much space for geological disposal. (author)

  10. Coherent Power Analysis in Multi-Level Studies Using Design Parameters from Surveys

    Science.gov (United States)

    Rhoads, Christopher

    2016-01-01

    Current practice for conducting power analyses in hierarchical trials using survey based ICC and effect size estimates may be misestimating power because ICCs are not being adjusted to account for treatment effect heterogeneity. Results presented in Table 1 show that the necessary adjustments can be quite large or quite small. Furthermore, power…

  11. Comparison of Anthropometry and Lower Limb Power Qualities According to Different Levels and Ranking Position of Competitive Surfers.

    Science.gov (United States)

    Fernandez-Gamboa, Iosu; Yanci, Javier; Granados, Cristina; Camara, Jesus

    2017-08-01

    Fernandez-Gamboa, I, Yanci, J, Granados, C, and Camara, J. Comparison of anthropometry and lower limb power qualities according to different levels and ranking position of competitive surfers. J Strength Cond Res 31(8): 2231-2237, 2017-The aim of this study was to compare competitive surfers' lower limb power output depending on their competitive level, and to evaluate the association between competition rankings. Twenty competitive surfers were divided according to the competitive level as follows: international (INT) or national (NAT), and competitive ranking (RANK1-50 or RANK51-100). Vertical jump and maximal peak power of the lower limbs were measured. No differences were found between INT and NAT surfers in the anthropometric variables, in the vertical jump, or in lower extremity power; although the NAT group had higher levels on the elasticity index, squat jumps (SJs), and counter movement jumps (CMJs) compared with the INT group. The RANK1-50 group had a lower biceps skinfold (p RANK1-50 group. Moderate to large significant correlations were obtained between the surfers' ranking position and some skinfolds, the sum of skinfolds, and vertical jump. Results demonstrate that surfers' physical performance seems to be an accurate indicator of ranking positioning, also revealing that vertical jump capacity and anthropometric variables play an important role in their competitive performance, which may be important when considering their power training.

  12. The Effects of a Maximal Power Training Cycle on the Strength, Maximum Power, Vertical Jump Height and Acceleration of High-Level 400-Meter Hurdlers

    Science.gov (United States)

    Balsalobre-Fernández, Carlos; Tejero-González, Carlos Mª; del Campo-Vecino, Juan; Alonso-Curiel, Dionisio

    2013-01-01

    The aim of this study was to determine the effects of a power training cycle on maximum strength, maximum power, vertical jump height and acceleration in seven high-level 400-meter hurdlers subjected to a specific training program twice a week for 10 weeks. Each training session consisted of five sets of eight jump-squats with the load at which each athlete produced his maximum power. The repetition maximum in the half squat position (RM), maximum power in the jump-squat (W), a squat jump (SJ), countermovement jump (CSJ), and a 30-meter sprint from a standing position were measured before and after the training program using an accelerometer, an infra-red platform and photo-cells. The results indicated the following statistically significant improvements: a 7.9% increase in RM (Z=−2.03, p=0.021, δc=0.39), a 2.3% improvement in SJ (Z=−1.69, p=0.045, δc=0.29), a 1.43% decrease in the 30-meter sprint (Z=−1.70, p=0.044, δc=0.12), and, where maximum power was produced, a change in the RM percentage from 56 to 62% (Z=−1.75, p=0.039, δc=0.54). As such, it can be concluded that strength training with a maximum power load is an effective means of increasing strength and acceleration in high-level hurdlers. PMID:23717361

  13. Pulsed low-level infrared laser alters mRNA levels from muscle repair genes dependent on power output in Wistar rats

    Science.gov (United States)

    Trajano, L. A. S. N.; Trajano, E. T. L.; Thomé, A. M. C.; Sergio, L. P. S.; Mencalha, A. L.; Stumbo, A. C.; Fonseca, A. S.

    2017-10-01

    Satellite cells are present in skeletal muscle functioning in the repair and regeneration of muscle injury. Activation of these cells depends on the expression of myogenic factor 5 (Myf5), myogenic determination factor 1(MyoD), myogenic regulatory factor 4 (MRF4), myogenin (MyoG), paired box transcription factors 3 (Pax3), and 7 (Pax7). Low-level laser irradiation accelerates the repair of muscle injuries. However, data from the expression of myogenic factors have been controversial. Furthermore, the effects of different laser beam powers on the repair of muscle injuries have been not evaluated. The aim of this study was to evaluate the effects of low-level infrared laser at different powers and in pulsed emission mode on the expression of myogenic regulatory factors and on Pax3 and Pax7 in injured skeletal muscle from Wistar rats. Animals that underwent cryoinjury were divided into three groups: injury, injury laser 25 Mw, and injury laser 75 mW. Low-level infrared laser irradiation (904 nm, 3 J cm-2, 5 kHz) was carried out at 25 and 75 mW. After euthanasia, skeletal muscle samples were withdrawn and the total RNA was extracted for the evaluation of mRNA levels from the MyoD, MyoG, MRF4, Myf5, Pax3, and Pax7 gene. Pax 7 mRNA levels did not alter, but Pax3 mRNA levels increased in the injured and laser-irradiated group at 25 mW. MyoD, MyoG, and MYf5 mRNA levels increased in the injured and laser-irradiated animals at both powers, and MRF4 mRNA levels decreased in the injured and laser-irradiated group at 75 mW. In conclusion, exposure to pulsed low-level infrared laser, by power-dependent effect, could accelerate the muscle repair process altering mRNA levels from paired box transcription factors and myogenic regulatory factors.

  14. Vulnerability of US thermoelectric power generation to climate change when incorporating state-level environmental regulations

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Lu; Hejazi, Mohamad; Li, Hongyi; Forman, Barton; Zhang, Xiao

    2017-07-10

    This study explores the interactions between climate and thermoelectric generation in the U.S. by coupling an Earth System Model with a thermoelectric power generation model. We validated model simulations of power production for selected power plants (~44% of existing thermoelectric capacity) against reported values. In addition, we projected future usable capacity for existing power plants under two different climate change scenarios. Results indicate that climate change alone may reduce average thermoelectric generating capacity by 2%-3% by the 2060s. Reductions up to 12% are expected if environmental requirements are enforced without waivers for thermal variation. This study concludes that the impact of climate change on the U.S. thermoelectric power system is less than previous estimates due to an inclusion of a spatially-disaggregated representation of environmental regulations and provisional variances that temporarily relieve power plants from permit requirements. This work highlights the significance of accounting for legal constructs in which the operation of power plants are managed, and underscores the effects of provisional variances in addition to environmental requirements.

  15. Use of Three-Level Power Converters in Wind-Driven Permanent-Magnet Synchronous Generators with Unbalanced Loads

    Directory of Open Access Journals (Sweden)

    Ming-Hung Chen

    2015-06-01

    Full Text Available This paper describes the design and implementation of three-level power converters for wind-driven permanent-magnet synchronous generators with unbalanced loads. To increase voltage stress and reduce current harmonics in the electrical power generated by a wind generator, a three-phase, three-level rectifier is used. Because a synchronous rotating frame is used on the AC-input side, the use of a neutral-point-clamped controller is proposed to increase the power factor to unity and reduce current harmonics. Furthermore, a novel six-leg inverter is proposed for transferring energy from the DC voltage to a three-phase, four-wire AC source with a constant voltage and a constant frequency. The power converters also contain output transformers and filters for power buffering and filtering, respectively. All three output phase voltages are fed back to control the inverter output during load variations. A digital signal processor is used as the core control device for implementing a 1.5 kV, 75 kW drive system. Experimental data show that the power factor is successfully increased to unity and the total current harmonic distortion is 3.2% on the AC-input side. The entire system can attain an efficiency of 91%, and the voltage error between the upper and lower capacitors is approximately zero. Experimental results that confirm the high performance of the proposed system are presented.

  16. Manpower development for each level of nuclear power plant personnel, experience and problems

    International Nuclear Information System (INIS)

    Martin, H.D.

    1986-01-01

    The following topics to be covered in this report are: Power plant organization and staff categories; basic education and training; practical experience requirements; effects of promotion and fluctuation; social problems associated with training abroad; technical problems and solutions. (orig.)

  17. Attributes of Full Scope Level 1 Probabilistic Safety Assessment (PSA) for Applications in Nuclear Power Plants

    International Nuclear Information System (INIS)

    2016-10-01

    This publication supersedes IAEA-TECDOC-1511, Determining the Quality of Probabilistic Safety Assessment (PSA) for Applications in Nuclear Power Plants (published in 2006), which provided detailed information on technical features of a restricted scope PSA aimed at analysing only internal initiating events caused by random component failures and human errors, and accident sequences that may lead to reactor core damage during operation. The present publication extends the scope of the PSA to cover a broader range of internal and external hazards, and low power and shutdown modes of nuclear power plant operation. In addition, some PSA aspects relevant to lessons learned from the accident at the Fukushima Daiichi nuclear power plant are also considered

  18. Demand response strategy management with active and reactive power incentive in the smart grid: a two-level optimization approach

    Directory of Open Access Journals (Sweden)

    Ryuto Shigenobu

    2017-05-01

    Full Text Available High penetration of distributed generators (DGs using renewable energy sources (RESs is raising some important issues in the operation of modern po­wer system. The output power of RESs fluctuates very steeply, and that include uncertainty with weather conditions. This situation causes voltage deviation and reverse power flow. Several methods have been proposed for solving these problems. Fundamentally, these methods involve reactive power control for voltage deviation and/or the installation of large battery energy storage system (BESS at the interconnection point for reverse power flow. In order to reduce the installation cost of static var compensator (SVC, Distribution Company (DisCo gives reactive power incentive to the cooperating customers. On the other hand, photovoltaic (PV generator, energy storage and electric vehicle (EV are introduced in customer side with the aim of achieving zero net energy homes (ZEHs. This paper proposes not only reactive power control but also active power flow control using house BESS and EV. Moreover, incentive method is proposed to promote participation of customers in the control operation. Demand response (DR system is verified with several DR menu. To create profit for both side of DisCo and customer, two level optimization approach is executed in this research. Mathematical modeling of price elasticity and detailed simulations are executed by case study. The effectiveness of the proposed incentive menu is demonstrated by using heuristic optimization method.

  19. A Comprehensive Investigation on the Short Circuit Performance of MW-level IGBT Power Modules

    DEFF Research Database (Denmark)

    Wu, Rui; Reigosa, Paula Diaz; Iannuzzo, Francesco

    2015-01-01

    This paper investigates the short circuit performance of commercial 1.7 kV / 1 kA IGBT power modules by means of a 6 kA Non-Destructive-Tester. A mismatched current distribution among the parallel chips has been observed, which can reduce the short circuit capability of the IGBT power module unde...... short circuit conditions. Further Spice simulations reveal that the stray parameters inside the module play an important role in contributing to such a phenomenon....

  20. Attempted development and cross-validation of predictive models of individual-level and organizational-level turnover of nuclear power operators

    International Nuclear Information System (INIS)

    Vasa-Sideris, S.J.

    1989-01-01

    Nuclear power accounts for 209% of the electric power generated in the U.S. by 107 nuclear plants which employ over 8,700 operators. Operator turnover is significant to utilities from the economic point of view since it costs almost three hundred thousand dollars to train and qualify one operator, and because turnover affects plant operability and therefore plant safety. The study purpose was to develop and cross-validate individual-level and organizational-level models of turnover of nuclear power plant operators. Data were obtained by questionnaires and from published data for 1983 and 1984 on a number of individual, organizational, and environmental predictors. Plants had been in operation for two or more years. Questionnaires were returned by 29 out of 50 plants on over 1600 operators. The objectives were to examine the reliability of the turnover criterion, to determine the classification accuracy of the multivariate predictive models and of categories of predictors (individual, organizational, and environmental) and to determine if a homology existed between the individual-level and organizational-level models. The method was to examine the shrinkage that occurred between foldback design (in which the predictive models were reapplied to the data used to develop them) and cross-validation. Results did not support the hypothesis objectives. Turnover data were accurate but not stable between the two years. No significant differences were detected between the low and high turnover groups at the organization or individual level in cross-validation. Lack of stability in the criterion, restriction of range, and small sample size at the organizational level were serious limitations of this study. The results did support the methods. Considerable shrinkage occurred between foldback and cross-validation of the models

  1. Fungal levels in houses in the Fukushima Daiichi Nuclear Power Plant evacuation zone after the Great East Japan Earthquake.

    Science.gov (United States)

    Shinohara, Naohide; Tokumura, Masahiro; Hashimoto, Kazuhiro; Asano, Katsuyoshi; Kawakami, Yuji

    2017-10-01

    Residences located within 20 km of the damaged Fukushima Daiichi Nuclear Power Plant were evacuated shortly after the Great East Japan Earthquake. The levels of airborne and surface fungi were measured in six houses in the evacuation zone in August 2012 and February 2013. Airborne fungal levels in all of the houses in the summer were higher than the environmental standard levels for residential houses published in Architectural Institute of Japan (>1000 colony-forming units [CFU]/m 3 ). In two houses whose residents rarely returned to visit, fungal levels were extremely high (>52,000 CFU/m 3 ). Although fungal levels in the winter were much lower than those in the summer, they were still higher than environmental standard levels in several houses. Indoor fungal levels were significantly inversely related to the frequency with which residents returned, but they were not correlated with the air exchange rates, temperature, humidity, or radiation levels. Cladosporium spp. and Penicillium spp. were detected in every house. Aspergillus section Circumdati (Aspergillus ochraceus group) was also detected in several houses. These fungi produced ochratoxin A and ochratoxin B, which have nephrotoxic and carcinogenic potential. The present study suggests that further monitoring of fungal levels is necessary in houses in the Fukushima Daiichi Nuclear Power Plant evacuation zone, and that some houses may require fungal disinfection. The results suggest that residents' health could be at risk owing to the high levels of airborne fungi and toxic fungi Aspergillus section Circumdati. Therefore, monitoring and decontamination/disinfection of fungi are strongly recommended before residents are allowed to return permanently to their homes. In addition, returning to home with a certain frequency and adequate ventilation are necessary during similar situations, e.g., when residents cannot stay in their homes for a long period, because fungal levels in houses in the Fukushima Daiichi

  2. Self-Powered Implantable Skin-Like Glucometer for Real-Time Detection of Blood Glucose Level In Vivo

    Science.gov (United States)

    Zhang, Wanglinhan; Zhang, Linlin; Gao, Huiling; Yang, Wenyan; Wang, Shuai; Xing, Lili; Xue, Xinyu

    2018-06-01

    Implantable bioelectronics for analyzing physiological biomarkers has recently been recognized as a promising technique in medical treatment or diagnostics. In this study, we developed a self-powered implantable skin-like glucometer for real-time detection of blood glucose level in vivo. Based on the piezo-enzymatic-reaction coupling effect of GOx@ZnO nanowire, the device under an applied deformation can actively output piezoelectric signal containing the glucose-detecting information. No external electricity power source or battery is needed for this device, and the outputting piezoelectric voltage acts as both the biosensing signal and electricity power. A practical application of the skin-like glucometer implanted in mouse body for detecting blood glucose level has been simply demonstrated. These results provide a new technique path for diabetes prophylaxis and treatment.

  3. DESIGN OF THE THREE-LEVEL MULTICRITERIAL STRATEGY OF HYBRID MARINE POWER PLANT CONTROL FOR A COMBINED PROPULSION COMPLEX

    Directory of Open Access Journals (Sweden)

    V.V. Budashko

    2017-04-01

    Full Text Available Purpose. Efficiency of hybrid ships power plants (SPP combined propulsion complexes (CPC by various criteria for energy management systems strategies. Methodology. Based on the classification system topologies SPP CPC for mechanical, electrical and hybrid types of motors schematic diagrams of management strategies for the criterion of minimum power consumption are defined. Changing the technical component of the traditional approach to building hybrid ships electric power systems (SEPS SPP CPC the principle of modifying the structure of SEPS is applied with the integration of additional static alternative power source as dynamic reserve, which allowed to meet modern requirements for energy efficiency, levels of vibration, noise and degradation effects produced to SPP CPC, in all areas of the energy for the transfer of power from energy to propellers. Modeling of power transmission of energy to propellers in MatLab/Simulink is conducted, using blocks of optimization library and definition of identity markers. Results. Major advantages and disadvantages SPP CPC depending on the topology of energy distribution systems are determined. According to the chosen structure system electricity characteristics were obtained in the process of power transmission SPP CPC and power systems and their control strategies in terms of increased efficiency and eliminate these drawbacks. And finally, mathematical apparatus for research in terms of the development of methods for designing and managing SPP hybrid CPC to reduced fuel consumption, emissions into the environment and improving maintainability, flexibility and comfort level are improved. Originality. The methodology for improving SPP CPC implementation by developing methods of identification markers mutually influencing processes in SPP CPC and the development of implementing these methods of settlement and information systems. Practical value. The method enables iterative optimization parameters SPP CPC, it

  4. Measurement of nuclear reactor noise at low power levels; Merenje nuklearnog reaktorskog suma na malim snagama

    Energy Technology Data Exchange (ETDEWEB)

    Velickovic, Lj; Petrovic, M [Boris Kidric Institute of nuclear sciences Vinca, Belgrade (Yugoslavia)

    1968-11-15

    Spatial and time dependence relation of neutrons from fission and other reactions in the reactor core result in non Poisson fluctuations of neutron density. Analytical formula developed for auto-correlation function includes physical parameters which characterize time behaviour of neutrons in the reactor system. Since auto-correlation function can be easily measured, it is a useful tool for experimental determination of these parameters. Noise from the ionization chamber was measured and analyzed by a digital computer. measurements were analyzed completely in the time domain (auto-correlation functions). This enabled separating the noise caused by neutron detection from the noise from neutron density fluctuation in the reactor. All the results can be analyzed by spatial independent reactor theory. Physical analysis of reactor noise was limited to determination of {beta}/l ratio from auto-correlation measurements at 0.5 W power level (RB reactor in Vinca). Three different reactor core lattices were analyzed (lattice pitch 8 cm, 11.3 cm and 14 cm). It was shown that parameter {beta}/l could be determined from auto-correlation measurements of neutron density with high precision (few percents) Prostorna i vremenska povezanost neutrona koji nastaju u fisiji i drugim procesima koji se desavaju u reaktoru dovodi do ne Poisson-ovih fluktuacija neutronske gustine. Analiticka formula, razvijena za autokorelacionu funkciju ovih fluktuacija, sadrzi fizicke parametre koji karakterisu vremensko ponasanje neutrona u reaktorskom sistemu. Kako autokorelaciona funkcija moze lako da se meri, ona je korisno sredstvo za eksperimentalno odredjivanje ovih parametara. Sum iz jonizacione komore digitalno je meren i analiziran u digitalnom racunaru. Merenja su kompletno analizirana u vremenskom domenu (autokorelacione funkeije). To je olaksalo razdvajanje suma izazvanog procesom neutronske detekcije od suma koji potice od fluktuacija neutronske gustine u reaktorskom sistemu. Svi rezultati

  5. An Assessment of Hiring Practices for Head Football Coaches at the "Power 5" NCAA Division I FBS Level

    Science.gov (United States)

    Saunders, Zachery S.

    2017-01-01

    This study examines the hiring practices for head football coaches at the NCAA Division I Football Bowl Subdivison (FBS) "Power 5" level. The research assesses the hiring practices used by athletic departments and evaluates various components of the hiring process that are utilized when hiring a head football coach. Additionally, this…

  6. A survey of low-level radioactive waste treatment methods and problem areas associated with commercial nuclear power plants

    International Nuclear Information System (INIS)

    Jolley, R.L.; Rodgers, B.R.

    1987-01-01

    A survey was made (June 1985) of technologies that were currently being used, those that had been discontinued, and those that were under consideration for treatment of low-level radioactive waste from the commercial nuclear power plants in the United States. The survey results included information concerning problems areas, areas needing research and development, and the use of mobile treatment facilities

  7. Analytical Design of Passive LCL Filter for Three-phase Two-level Power Factor Correction Rectifiers

    DEFF Research Database (Denmark)

    Kouchaki, Alireza; Nymand, Morten

    2017-01-01

    This paper proposes a comprehensive analytical LCL filter design method for three-phase two-level power factor correction rectifiers (PFCs). The high frequency converter current ripple generates the high frequency current harmonics that need to be attenuated with respect to the grid standards...

  8. Conditional quantum entropy power inequality for d-level quantum systems

    Science.gov (United States)

    Jeong, Kabgyun; Lee, Soojoon; Jeong, Hyunseok

    2018-04-01

    We propose an extension of the quantum entropy power inequality for finite dimensional quantum systems, and prove a conditional quantum entropy power inequality by using the majorization relation as well as the concavity of entropic functions also given by Audenaert et al (2016 J. Math. Phys. 57 052202). Here, we make particular use of the fact that a specific local measurement after a partial swap operation (or partial swap quantum channel) acting only on finite dimensional bipartite subsystems does not affect the majorization relation for the conditional output states when a separable ancillary subsystem is involved. We expect our conditional quantum entropy power inequality to be useful, and applicable in bounding and analyzing several capacity problems for quantum channels.

  9. The level of influence of trust, commitment, cooperation, and power in the interorganizational relationships of Brazilian credit cooperatives

    Directory of Open Access Journals (Sweden)

    Denise Maria Martins

    Full Text Available Abstract This article aims to analyze the level of influence of trust, commitment, cooperation, and power in the interrelationships of individual credit cooperatives and their central organization in Brazil. The quantitative and descriptive research was developed in unique credit unions linked to the Central Bank of Brazil and the Organization of Brazilian Cooperatives. The data were analyzed using structural equation modeling, with the estimation through partial least squares. The results obtained for the coefficients of determination (R2 of the endogenous latent variables confirmed the assumptions found in the theoretical models of Morgan and Hunt (1994 and Coote, Forrest, and Tam (2003. Statistical significance was also found in the relationships between power and trust, commitment and cooperation, trust and commitment, trust and cooperation, and power and commitment. However, in this study the relationship between power and commitment characterized the significance and was positive between the individual credit cooperatives and their central organization. This is in line with the understanding that power is the solution to resolving conflicts. The research identifies how the constructs of trust, commitment, cooperation, and power show relevance to the alignment of relations between individual credit cooperatives and their central organization.

  10. Working together versus working autonomously: a new power-dependence perspective on the individual-level of analysis.

    Science.gov (United States)

    de Jong, Simon B

    2014-01-01

    Recent studies have indicated that it is important to investigate the interaction between task interdependence and task autonomy because this interaction can affect team effectiveness. However, only a limited number of studies have been conducted and those studies focused solely on the team level of analysis. Moreover, there has also been a dearth of theoretical development. Therefore, this study develops and tests an alternative theoretical perspective in an attempt to understand if, and if so why, this interaction is important at the individual level of analysis. Based on interdependence theory and power-dependence theory, we expected that highly task-interdependent individuals who reported high task autonomy would be more powerful and better performers. In contrast, we expected that similarly high task-interdependent individuals who reported less task autonomy would be less powerful and would be weaker performers. These expectations were supported by multi-level and bootstrapping analyses performed on a multi-source dataset (self-, peer-, manager-ratings) comprised of 182 employees drawn from 37 teams. More specifically, the interaction between task interdependence and task autonomy was γ =.128, p power and γ =.166, p <.05 for individual performance. The 95% bootstrap interval ranged from .0038 to .0686.

  11. Optimal Level of Woody Biomass Co-Firing with Coal Power Plant Considering Advanced Feedstock Logistics System

    Directory of Open Access Journals (Sweden)

    Sangpil Ko

    2018-05-01

    Full Text Available Co-firing from woody biomass feedstock is one of the alternatives toward increased use of renewable feedstock in existing coal power plants. However, the economic level of co-firing at a particular power plant depends on several site-specific factors. Torrefaction has been identified recently as a promising biomass pretreatment option to lead to reduction of the feedstock delivered cost, and thus facilitate an increase in the co-firing ratio. In this study, a mixed integer linear program (MILP is developed to integrate supply chain of co-firing and torrefaction process and find the optimal level of biomass co-firing in terms of minimized transportation and logistics costs, with or without tax credits. A case study of 26 existing coal power plants in three Great Lakes States of the US is used to test the model. The results reveal that torrefaction process can lead to higher levels of co-firing, but without the tax credit, the effect is limited to the low capacity of power plants. The sensitivity analysis shows that co-firing ratio has higher sensitivity to variation in capital and operation costs of torrefaction than to the variation in the transportation and feedstock purchase costs.

  12. Drivers for the Value of Demand Response under Increased Levels of Wind and Solar Power; NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    Hale, Elaine

    2015-07-30

    Demand response may be a valuable flexible resource for low-carbon electric power grids. However, there are as many types of possible demand response as there are ways to use electricity, making demand response difficult to study at scale in realistic settings. This talk reviews our state of knowledge regarding the potential value of demand response in several example systems as a function of increasing levels of wind and solar power, sometimes drawing on the analogy between demand response and storage. Overall, we find demand response to be promising, but its potential value is very system dependent. Furthermore, demand response, like storage, can easily saturate ancillary service markets.

  13. System-Level Power Optimization for a ΣΔ D/A Converter for Hearing-Aid Application

    DEFF Research Database (Denmark)

    Pracný, Peter; Jørgensen, Ivan Harald Holger; Bruun, Erik

    2013-01-01

    This paper deals with a system-level optimization of a back-end of audio signal processing chain for hearing-aids, including a sigma-delta modulator digital-to-analog converter (DAC) and a Class D power amplifier. Compared to other stateof-the-art designs dealing with sigma-delta modulator design...... hearing-aid audio back-end system resulting in less hardware and power consumption in the interpolation filter, in the sigma-delta modulator and reduced switching rate of the Class D output stage....

  14. No change in lower limb extension power during a hospital stay in geriatric patients, despite improved functional level

    DEFF Research Database (Denmark)

    Karlsen, Anders; Loeb, Mads Rohde; Turtumoeygaard, Ida Fanny

    2017-01-01

    The aim of the current study was to evaluate changes in lower limb extension power (LLEP) during hospitalization in older medical patients. LLEP was measured in a PowerRig at admission (day 2 to 4; mean ± SD: day 2.5 ± 0.8) and before discharge (day 5-11; mean ± SD: day 8.4 ± 2.2) in 33 older med...... improvements in older geriatric patients occur in the absence of improvements in LLEP. Individual changes in LLEP were not related to the changes in function or to the daily activity level in the patients....

  15. Implantable Self-Powered Low-Level Laser Cure System for Mouse Embryonic Osteoblasts' Proliferation and Differentiation.

    Science.gov (United States)

    Tang, Wei; Tian, Jingjing; Zheng, Qiang; Yan, Lin; Wang, Jiangxue; Li, Zhou; Wang, Zhong Lin

    2015-08-25

    Bone remodeling or orthodontic treatment is usually a long-term process. It is highly desirable to speed up the process for effective medical treatment. In this work, a self-powered low-level laser cure system for osteogenesis is developed using the power generated by the triboelectric nanogenerator. It is found that the system significantly accelerated the mouse embryonic osteoblasts' proliferation and differentiation, which is essential for bone and tooth healing. The system is further demonstrated to be driven by a living creature's motions, such as human walking or a mouse's breathing, suggesting its practical use as a portable or implantable clinical cure for bone remodeling or orthodontic treatment.

  16. The Relative Importance of Low Significance Level and High Power in Multiple Tests of Significance.

    Science.gov (United States)

    Westermann, Rainer; Hager, Willi

    1983-01-01

    Two psychological experiments--Anderson and Shanteau (1970), Berkowitz and LePage (1967)--are reanalyzed to present the problem of the relative importance of low Type 1 error probability and high power when answering a research question by testing several statistical hypotheses. (Author/PN)

  17. Megawatt Power Level 120 GHz Gyrotrons for ITER Start-Up

    Energy Technology Data Exchange (ETDEWEB)

    Choi, E M; Marchewka, C; Mastovsky, I; Shapiro, M A; Sirigiri, J R; Temkin, R J [MIT - Plasma Science and Fusion Center, NW16-186, 167 Albany Street, Cambridge, MA 02139 (United States)

    2005-01-01

    We report operation of a 110 GHz gyrotron with 1.67 MW of output power measured in short pulses (3{mu}s) at an efficiency of 42% in the TE{sub 22,6} mode. We also present a preliminary design of a 1 MW, 120 GHz gyrotron for ITER start-up with an efficiency greater than 50%.

  18. Megawatt Power Level 120 GHz Gyrotrons for ITER Start-Up

    International Nuclear Information System (INIS)

    Choi, E M; Marchewka, C; Mastovsky, I; Shapiro, M A; Sirigiri, J R; Temkin, R J

    2005-01-01

    We report operation of a 110 GHz gyrotron with 1.67 MW of output power measured in short pulses (3μs) at an efficiency of 42% in the TE 22,6 mode. We also present a preliminary design of a 1 MW, 120 GHz gyrotron for ITER start-up with an efficiency greater than 50%

  19. Impact of high level penetration of Wind Turbines on Power System Transient Stability

    DEFF Research Database (Denmark)

    Kalogiannis, Theodoros; Llano, Enrique Muller; Hoseinzadeh, Bakhtyar

    2015-01-01

    generators differ from the conventional ones in their inertial contribution to the grid, therefore, in most cases the ability of the system to maintain a stable operation is declined. To investigate this, two standard models are designed in PowerFactory software. The first is used to characterize system...

  20. Teachers, School Boards, and the Power of Money: How the Right Wins at the Local Level

    Science.gov (United States)

    Schirmer, Eleni B.; Apple, Michael W.

    2016-01-01

    This article examines national conservative political advocacy groups' growing interest in local politics, and analyzes how they form alliances and gain political power. Following efforts to restrict collective bargaining for Wisconsin public employees, Kenosha school board members' attempts to legally protect teachers' rights provoked concern…

  1. Reconfigurable, Bi-Directional Flexfet Level Shifter for Low-Power, Rad-Hard Integration

    Science.gov (United States)

    DeGregorio, Kelly; Wilson, Dale G.

    2009-01-01

    Two prototype Reconfigurable, Bi-directional Flexfet Level Shifters (ReBiLS) have been developed, where one version is a stand-alone component designed to interface between external low voltage and high voltage, and the other version is an embedded integrated circuit (IC) for interface between internal low-voltage logic and external high-voltage components. Targeting stand-alone and embedded circuits separately allows optimization for these distinct applications. Both ReBiLS designs use the commercially available 180-nm Flex fet Independently Double-Gated (IDG) SOI CMOS (silicon on insulator, complementary metal oxide semiconductor) technology. Embedded ReBiLS circuits were integrated with a Reed-Solomon (RS) encoder using CMOS Ultra-Low-Power Radiation Tolerant (CULPRiT) double-gated digital logic circuits. The scope of the project includes: creation of a new high-voltage process, development of ReBiLS circuit designs, and adjustment of the designs to maximize performance through simulation, layout, and manufacture of prototypes. The primary technical objectives were to develop a high-voltage, thick oxide option for the 180-nm Flexfet process, and to develop a stand-alone ReBiLS IC with two 8-channel I/O busses, 1.8 2.5 I/O on the low-voltage pins, 5.0-V-tolerant input and 3.3-V output I/O on the high-voltage pins, and 100-MHz minimum operation with 10-pF external loads. Another objective was to develop an embedded, rad-hard ReBiLS I/O cell with 0.5-V low-voltage operation for interface with core logic, 5.0-V-tolerant input and 3.3-V output I/O pins, and 100-MHz minimum operation with 10- pF external loads. A third objective was to develop a 0.5- V Reed-Solomon Encoder with embedded ReBilS I/O: Transfer the existing CULPRiT RS encoder from a 0.35-micron bulk-CMOS process to the ASI 180-nm Flexfet, rad-hard SOI Process. 0.5-V low-voltage core logic. 5.0-V-tolerant input and 3.3-V output I/O pins. 100-MHz minimum operation with 10- pF external loads. The stand

  2. An influence of occupational exposure on level of chromosome aberrations in nuclear power plant workers

    International Nuclear Information System (INIS)

    Birute Griciene; Grazina Slapsyte

    2007-01-01

    Complete text of publication follows. Objective. The workers of Ignalina Nuclear Power Plant (INPP) receive the highest occupational ionising radiation doses in Lithuania. Their occupational exposure results mainly from external low LET gamma radiation. Some workers receive additional internal and neutron exposure. Though exposure doses are generally low and don't exceed the annual dose limit, the higher doses are obtained during outages. The aim of the present study was to analyse chromosome aberration frequencies in lymphocytes of INPP workers exposed to the different types of ionising radiation. Methods. The blood sampling of 52 INPP male workers was performed in 2004-2006. For 29 workers radiation exposure resulted from the external gamma rays only. Their mean annual dose averaged over the 3-year period prior blood sampling was 11.7±8.7 mSv. The mean cumulative dose - 197.7±174.7 mSv. 15 workers had an intake of gamma radionuclides ( 60 Co, 137 Cs), contributing to the doses less than 0.1 mSv. Their mean cumulative dose - 278.2±191.9 mSv. The mean annual dose averaged over the 3-year period prior blood sampling was 11.8±5.3 mSv. For 8 subjects neutron doses below 0.2 mSv were recorded. Their mean annual dose averaged over the 3-year period prior blood sampling was 7.0±2.9 mSv. The mean cumulative dose was 241.8±93.0 mSv. Heparinized venous blood samples were taken and cultures were initiated according to the standard procedures. Phytohaemagglutinin (7.8 μg/ml) stimulated cultures were incubated at 37degC for 72 hours in RPMI 1640 medium supplemented with 12% heat-inactivated newborn calf serum, 40 μg/ml gentamycin. Colchicine was added to the culture during the initiation at a final concentration of 0,25 μg/ml. The harvested lymphocytes were treated with hypotonic KCl (0,075 M) and then fixed in methanol-glacial acetic acid (3:1). Flame-dried slides were stained with Giemsa, coded and scored blind. Generally 500 first-division cells per individual were

  3. Determination of allowable ramp power levels to maintain the mechanical integrity for 14x14, 16x16 and 17x17 KOFAs

    International Nuclear Information System (INIS)

    Lee, Chan Bok; Kim, Ki Hang; Kim, Kyu Tae

    1991-11-01

    Transient behavior of the fuel rods with various rod power histories for 17x17 KOFA fuels has been calculated and evaluated, and sensitivity analyses of the key parameters such as rod power history before ramp, fast neutron flux and cycle length have also been performed. Results show that cladding strain is more limiting in determining the allowable ramp power level than fuel centerline temperature, and neutron flux has greatest influence on fuel transient behavior among rod power history before ramp, fast neutron flux and cycle length. Based upon the above results, allowable ramp power levels versus burnup for 14x14, 16x16 and 17x17 KOFA fuels were determined for the rods with different initial power levels of F xy = 0.6, 0.8, 1.0 and 1.2, which shows that the rod with lower initial power level gives lower allowable ramp power level. It can be said, therefore, that if the ramp power level of the rod at certain initial power level and burnup is less than the corresponding allowable ramp power level, the transient behavior of the rod satisfy the fuel rod design criteria. (Author)

  4. Development of a fully-coupled, all atates, all hazards level 2 PSA at leibstadt nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Zvoncek, Pavol; Nusbaumer, Olivier [Safety Compliance and Technical Support Department, Leibstadt Nuclear Power Plant, Leibstadt (Sweden); Torri, Alfred [Risk Management Associates, Inc., Encinitas (United States)

    2017-03-15

    This paper describes the development process, the innovative techniques used and insights gained from the latest integrated, full scope, multistate Level 2 PSA analysis conducted at the Leibstadt Nuclear Power Plant (KKL), Switzerland. KKL is a modern single-unit General Electric Boiling Water Reactor (BWR/6) with Mark III Containment, and a power output of 3600MWth/1200MWe, the highest among the five operating reactors in Switzerland. A Level 2 Probabilistic Safety Assessment (PSA) analyses accident phenomena in nuclear power plants, identifies ways in which radioactive releases from plants can occur and estimates release pathways, magnitude and frequency. This paper attempts to give an overview of the advanced modeling techniques that have been developed and implemented for the recent KKL Level 2 PSA update, with the aim of systematizing the analysis and modeling processes, as well as complying with the relatively prescriptive Swiss requirements for PSA. The analysis provides significant insights into the absolute and relative importance of risk contributors and accident prevention and mitigation measures. Thanks to several newly developed techniques and an integrated approach, the KKL Level 2 PSA report exhibits a high degree of reviewability and maintainability, and transparently highlights the most important risk contributors to Large Early Release Frequency (LERF) with respect to initiating events, components, operator actions or seismic component failure probabilities (fragilities)

  5. A methodology for Level 2 PSA evaluation with consideration of specific features for Low Power Shutdown Probabilistic Safety Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Gab; Seok, Ho [KEPCO-ENC, Yongin (Korea, Republic of)

    2015-05-15

    The primary objective of the Level 2 PSA during Lower Power/Shutdown (LPSD) operation is to provide insights into potential plant vulnerabilities with regard to accident progression. The shutdown risk information can be used to provide the information to develop outage risk management guidelines. The LPSD Level 2 analysis utilizes much of the at-power Level 2 analysis for bounding, conservative treatment of severe accident phenomena. But, for some portions of the analysis including Plant Operational States (POSs), LPSD-specific evaluations such as UPC related to the containment Equipment Hatch (E/H) with 4 bolts, Reactor Coolant System (RCS) Not Intact for severe accident phenomena are desired for realistic evaluation. All POSs are evaluated for their Large Release Frequency (LRF). Some POSs are evaluated conservatively utilizing the at-power models, and other POSs are evaluated in specific analysis. The overall LPSD Level 2 model is evaluated. If the containment E/H and one of the two doors on each of the personal air locks are closed as containment is operable at reduced RCS inventory operation, LRF is expected to be less than 10% of LPSD CDF.

  6. Methodologies for rapid evaluation of seismic demand levels in nuclear power plant structures

    International Nuclear Information System (INIS)

    Manrique, M.; Asfura, A.; Mukhim, G.

    1990-01-01

    A methodology for rapid assessment of both acceleration spectral peak and 'zero period acceleration' (ZPA) values for virtually any major structure in a nuclear power plant is presented. The methodology is based on spectral peak and ZPA amplification factors, developed from regression analyses of an analytical database. The developed amplification factors are applied to the plant's design ground spectrum to obtain amplified response parameters. A practical application of the methodology is presented. This paper also presents a methodology for calculating acceleration response spectrum curves at any number of desired damping ratios directly from a single known damping ratio spectrum. The methodology presented is particularly useful and directly applicable to older vintage nuclear power plant facilities (i.e. such as those affected by USI A-46). The methodology is based on principles of random vibration theory. The methodology has been implemented in a computer program (SPECGEN). SPECGEN results are compared with results obtained from time history analyses. (orig.)

  7. Kilowatt-level cladding light stripper for high-power fiber laser.

    Science.gov (United States)

    Yan, Ping; Sun, Junyi; Huang, Yusheng; Li, Dan; Wang, Xuejiao; Xiao, Qirong; Gong, Mali

    2017-03-01

    We designed and fabricated a high-power cladding light stripper (CLS) by combining a fiber-etched CLS with a cascaded polymer-recoated CLS. The etched fiber reorganizes the numerical aperture (NA) distribution of the cladding light, leading to an increase in the leakage power and a flatter distribution of the leakage proportion in the cascaded polymer-recoated fiber. The index distribution of the cascaded polymer-recoated fiber is carefully designed to ensure an even leakage of cladding light. More stages near the index of 1.451 are included to disperse the heat. The CLS is capable of working consistently under 1187 W of cladding light with an attenuation of 26.59 dB, and the highest local temperature is less than 35°C.

  8. Market oriented and rational use of energy and power. Level of competence and need of skill

    International Nuclear Information System (INIS)

    Morch, Andrei Z.; Groenli, Helle

    2001-03-01

    This report surveys the existing research and development (R and D) skill in Norway in the field of ''Market oriented and rational use of energy and power''. The need for skills upgrading and future R and D is discussed. Four areas for R and D are identified as especially important: (1) external conditions, (2) end user behavior, (3) the interplay of all issues related to the end user's competence, and (4) information and communication technology

  9. SEB circuit-level model in N-channel power MOSFETs

    International Nuclear Information System (INIS)

    Liu, J.; Schrimpf, R.D.; Massengill, L.; Galloway, K.F.

    1999-01-01

    A Single Event Burnout (SEB) circuit model has been developed. The dependence of SEB sensitivity on various parameters is presented and compared with experimental results. The parasitic resistance and capacitance of the device as well as the circuit parameters contribute to the length of SEB pulse. Increasing the switching frequency of the power MOSFET may be a possible way to prevent SEB in applications. (authors)

  10. Wearable Sensor System Powered by a Biofuel Cell for Detection of Lactate Levels in Sweat (Postprint)

    Science.gov (United States)

    2016-05-04

    impacted the trends of economic development in the last 20 years.30 If trends continue then development of self-powered sensing systems may have an impact...experiments were conducted with a three-electrode setup using a conventional potentiostat: Bi- ologic Model 1:VMP3 multichannel potentiostat/galvanostat. All...Potassium nitrate , methylene green zinc chloride double salt, urea, and tetramethyl orthosilicate (TMOS) were purchased from Sigma Aldrich (St. Louis

  11. Impact of the Power Sector Development on the Emission Level in Lithuania

    International Nuclear Information System (INIS)

    Galinis, A.; Tarvydas, D.

    1998-01-01

    The analyses carried out show that further necessary investments into safety improvements of the Ignalina NPP satisfy the criterion of the least cost power sector development and it should be kept in operation until the end of its technical life time. Modular CHP with diesel engines or gas turbines, or new CCGT will be the most attractive source of electricity generation if new capacities are required. The Ignalina NPP also has crucial impact on all kind of emissions in Lithuania. If this power plant is shut down, the requirement of the Kyoto Protocol for CO 2 mitigation will be violated already in 2011, even in the case of the most pessimistic economy growth and electricity export scenario. In the case of the further operation of the nuclear power plant Lithuania will be able to fulfil the requirement of the Kyoto Protocol during the whole study period. However, during temporary shut down of the nuclear plant for safety upgrade or rechannelling of reactors some reduction of electricity export will be necessary. (author)

  12. Saturated Adaptive Output-Feedback Power-Level Control for Modular High Temperature Gas-Cooled Reactors

    Directory of Open Access Journals (Sweden)

    Zhe Dong

    2014-11-01

    Full Text Available Small modular reactors (SMRs are those nuclear fission reactors with electrical output powers of less than 300 MWe. Due to its inherent safety features, the modular high temperature gas-cooled reactor (MHTGR has been seen as one of the best candidates for building SMR-based nuclear plants with high safety-level and economical competitive power. Power-level control is crucial in providing grid-appropriation for all types of SMRs. Usually, there exists nonlinearity, parameter uncertainty and control input saturation in the SMR-based plant dynamics. Motivated by this, a novel saturated adaptive output-feedback power-level control of the MHTGR is proposed in this paper. This newly-built control law has the virtues of having relatively neat form, of being strong adaptive to parameter uncertainty and of being able to compensate control input saturation, which are given by constructing Lyapunov functions based upon the shifted-ectropies of neutron kinetics and reactor thermal-hydraulics, giving an online tuning algorithm for the controller parameters and proposing a control input saturation compensator respectively. It is proved theoretically that input-to-state stability (ISS can be guaranteed for the corresponding closed-loop system. In order to verify the theoretical results, this new control strategy is then applied to the large-range power maneuvering control for the MHTGR of the HTR-PM plant. Numerical simulation results show not only the relationship between regulating performance and control input saturation bound but also the feasibility of applying this saturated adaptive control law practically.

  13. A low-power and small-area column-level ADC for high frame-rate CMOS pixel sensor

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, L., E-mail: liang.zhang@iphc.cnrs.fr [School of Physics, Key Laboratory of Particle Physics and Particle Irradiation, Shandong University, 250100 Jinan (China); Institut Pluridisciplinaire Hubert Curien, University of Strasbourg, CNRS/IN2P3/UDS, 23 rue du loess, BP 28, 67037 Strasbourg (France); Morel, F.; Hu-Guo, C.; Hu, Y. [Institut Pluridisciplinaire Hubert Curien, University of Strasbourg, CNRS/IN2P3/UDS, 23 rue du loess, BP 28, 67037 Strasbourg (France)

    2014-07-01

    CMOS pixel sensors (CPS) have demonstrated performances meeting the specifications of the International Linear Collider (ILC) vertex detector (VTX). This paper presents a low-power and small-area 4-bit column-level analog-to-digital converter (ADC) for CMOS pixel sensors. The ADC employs a self-timed trigger and completes the conversion by performing a multi-bit/step approximation. As in the outer layers of the ILC vertex detector hit density is of the order of a few per thousand, in order to reduce power consumption, the ADC is designed to work in two modes: active mode and idle mode. The ADC is fabricated in a 0.35 μm CMOS process with a pixel pitch of 35 μm. It is implemented with 48 columns in a sensor prototype. Each column ADC covers an area of 35 ×545 μm{sup 2}. The measured temporal noise and Fixed Pattern Noise (FPN) are 0.96 mV and 0.40 mV, respectively. The power consumption, for a 3 V supply and 6.25 MS/s sampling rate, is 486 μW during idle time, which is by far the most frequently employed one. This value rises to 714 μW in the case of the active mode. The measured differential nonlinearity (DNL) and integral nonlinearity (INL) are 0.49/−0.28 LSB and 0.29/−0.20 LSB, respectively. - Highlights: • CMOS sensor integrated with column-level ADC is proposed for ILC VTX outer layers. • A low-power and small-area column-level ADC for high frame-rate CPS is presented. • The test results demonstrate the power and area efficiency. • The architecture is suitable for the outer layer CMOS sensors.

  14. A low-power and small-area column-level ADC for high frame-rate CMOS pixel sensor

    International Nuclear Information System (INIS)

    Zhang, L.; Morel, F.; Hu-Guo, C.; Hu, Y.

    2014-01-01

    CMOS pixel sensors (CPS) have demonstrated performances meeting the specifications of the International Linear Collider (ILC) vertex detector (VTX). This paper presents a low-power and small-area 4-bit column-level analog-to-digital converter (ADC) for CMOS pixel sensors. The ADC employs a self-timed trigger and completes the conversion by performing a multi-bit/step approximation. As in the outer layers of the ILC vertex detector hit density is of the order of a few per thousand, in order to reduce power consumption, the ADC is designed to work in two modes: active mode and idle mode. The ADC is fabricated in a 0.35 μm CMOS process with a pixel pitch of 35 μm. It is implemented with 48 columns in a sensor prototype. Each column ADC covers an area of 35 ×545 μm 2 . The measured temporal noise and Fixed Pattern Noise (FPN) are 0.96 mV and 0.40 mV, respectively. The power consumption, for a 3 V supply and 6.25 MS/s sampling rate, is 486 μW during idle time, which is by far the most frequently employed one. This value rises to 714 μW in the case of the active mode. The measured differential nonlinearity (DNL) and integral nonlinearity (INL) are 0.49/−0.28 LSB and 0.29/−0.20 LSB, respectively. - Highlights: • CMOS sensor integrated with column-level ADC is proposed for ILC VTX outer layers. • A low-power and small-area column-level ADC for high frame-rate CPS is presented. • The test results demonstrate the power and area efficiency. • The architecture is suitable for the outer layer CMOS sensors

  15. Assessment of levelized cost of electricity for a 10-MW solar chimney power plant in Yinchuan China

    International Nuclear Information System (INIS)

    Guo, Penghua; Zhai, Yaxin; Xu, Xinhai; Li, Jingyin

    2017-01-01

    Highlights: • An unsteady model is proposed for annual power generation prediction of SCPPs. • LCOE of a 10-MW SCPP in China is estimated through a cost benefit analysis. • Cost advantage and concessional loan under conditions in China are considered. • SCPP is proven to be economically feasible under favorable conditions in China. - Abstract: Solar chimney power plant (SCPP) is a promising renewable energy technology that needs policy support and market cultivation at the early stage of its development. An accurate prediction of the levelized cost of electricity (LCOE) can be used as basis for crafting effective support policies. This study presents an unsteady theoretical model that considers hourly meteorological data and soil heat storage in estimating the annual power generation of an SCPP. A cost benefit model is adopted to calculate the LCOE of a 10-MW SCPP in Yinchuan, a representative geographical location in the Northwestern region of China. By considering the cost advantage of China, the concessional loan, as well as the low operation and maintenance cost, the LCOE of the SCPP is estimated to be 0.4178 Yuan/kWh, which can compete with those of wind power and solar PV in China. This work lays a good foundation for the accurate prediction of power generation and provides a reference for the Chinese government in crafting effective support policies for SCPPs.

  16. Efforts of load leveling in Tohoku Electric Power Co. Inc.; Tohoku denryoku no fuka heijunka eno torikumi ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-05-01

    This paper describes efforts of load leveling in Tohoku Electric Power Co., Inc. from the viewpoint of the rate system and business development. For the approach from the rate system, various rate menus for the peak shift have been arranged for domestic and large industry customers. To create the midnight demand, spread and expansion of electric hot water service are promoted. Consequently, the contract of midnight power has reached 914,000 kW at the end of 1995, which was 774,000 kW in 1985. To spread the ice regenerative air conditioning systems, the grant of incentive to the manufacturers and special discount of electricity rate have been conducted. These systems have been introduced in the eight places of Tohoku Electric Power`s business. The spread incident system has been created to introduce the automatic vending machines for beverages with the power peak cut function. Unused energy, such as exhaust heat from the non-treated sewage water and substations has been utilized as a heat supply project for city redevelopment. Multi-functional heat pump with regenerative function has been developed. This system aims at the peak shift by combining multi-functional heat pump and electric hot water service. 2 figs., 2 tabs.

  17. PSCAD modeling of a two-level space vector pulse width modulation algorithm for power electronics education

    Directory of Open Access Journals (Sweden)

    Ahmet Mete Vural

    2016-09-01

    Full Text Available This paper presents the design details of a two-level space vector pulse width modulation algorithm in PSCAD that is able to generate pulses for three-phase two-level DC/AC converters with two different switching patterns. The presented FORTRAN code is generic and can be easily modified to meet many other kinds of space vector modulation strategies. The code is also editable for hardware programming. The new component is tested and verified by comparing its output as six gating signals with those of a similar component in MATLAB library. Moreover the component is used to generate digital signals for closed-loop control of STATCOM for reactive power compensation in PSCAD. This add-on can be an effective tool to give students better understanding of the space vector modulation algorithm for different control tasks in power electronics area, and can motivate them for learning.

  18. Method of levelized discounted costs applied in economic evaluation of nuclear power plant project

    International Nuclear Information System (INIS)

    Tian Li; Wang Yongqing; Liu Jingquan; Guo Jilin; Liu Wei

    2000-01-01

    The main methods of economic evaluation of bid which are in common use are introduced. The characteristics of levelized discounted cost method and its application are presented. The method of levelized discounted cost is applied to the cost calculation of a 200 MW nuclear heating reactor economic evaluation. The results indicate that the method of levelized discounted costs is simple, feasible and which is considered most suitable for the economic evaluation of various case. The method is suggested which is used in the national economic evaluation

  19. Optimal sampling period of the digital control system for the nuclear power plant steam generator water level control

    International Nuclear Information System (INIS)

    Hur, Woo Sung; Seong, Poong Hyun

    1995-01-01

    A great effort has been made to improve the nuclear plant control system by use of digital technologies and a long term schedule for the control system upgrade has been prepared with an aim to implementation in the next generation nuclear plants. In case of digital control system, it is important to decide the sampling period for analysis and design of the system, because the performance and the stability of a digital control system depend on the value of the sampling period of the digital control system. There is, however, currently no systematic method used universally for determining the sampling period of the digital control system. Generally, a traditional way to select the sampling frequency is to use 20 to 30 times the bandwidth of the analog control system which has the same system configuration and parameters as the digital one. In this paper, a new method to select the sampling period is suggested which takes into account of the performance as well as the stability of the digital control system. By use of the Irving's model steam generator, the optimal sampling period of an assumptive digital control system for steam generator level control is estimated and is actually verified in the digital control simulation system for Kori-2 nuclear power plant steam generator level control. Consequently, we conclude the optimal sampling period of the digital control system for Kori-2 nuclear power plant steam generator level control is 1 second for all power ranges. 7 figs., 3 tabs., 8 refs. (Author)

  20. Mean sea level and change in the hydrological regime off Loviisa power plant around the year 2050

    International Nuclear Information System (INIS)

    Maelkki, P.; Voipio, A.

    1985-03-01

    On the request of Imatran Voima Oy, the Institute of Marine Research has made an estimate on the future sea level off Loviisa Power Plant. The estimate is based on observationsof mean sea level in the Gulf of Finland. The stations used are Helsinki (observations since 1904) and Hamina (observations since 1928). A litterature review was made in order to estimate impact of climate change on environmental conditions. The results presented are mainly based on various estimates of meterorological Global Circulation Models (GCM). Their usefulness in the connection is briefly discussed

  1. Biographical learning in top-level coaching - personal styles and the power of practical sense

    DEFF Research Database (Denmark)

    Christensen, Mette Krogh

    There is a growing body of studies in sports coaching cultures, comprising research focusing on the individual learning processes and life histories of top-level coaches. Even if top-level sport has become increasingly professionalized, the role of the top-level coach and the developmental pathways...... of practical sense of talent. I base the paper on a sociological analysis of in-depth interviews with eight Danish top-level football coaches about their pathways to expertise. Results illustrate two interwoven aspects of coaching expertise: 1) the coaches’ descriptions of their development of expertise...... as a “personal journey” and a matter of unique pathways, and 2) the coaches’ use of social constructed practical sense in their daily work, particularly in identification and assessment of skillfulness and talent in young footballers. The results point to an important challenge in coach education and coach...

  2. Load levelling measures being tackled by shikoku Electric Power Co. Inc.; Shikoku Denryoku Kabushi Kaisha no fuka heijunka eno torikumi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-11-01

    For the electric power companies, the activity of pushing forward the load levelling contributes greatly to the curtailment of cost by means of effective formation and utilization of facilities. It is planned to take up more positive activities with a target of 3% improvement in the load factor in ten years. Concrete measures for further promotion of load levelling are the diversity of the rate menu of appraising the load levelling effort of the customers and the promotion of the spread of equipment and systems relating to load levelling such as electric water heating apparatuses and thermal energy storage air conditioning systems. The rate system has been reviewed taking the opportunity of rate revision made in January, 1996. Particularly, further load shift to midnight time zone is expected as a result of better rate incentive for customers which is brought about by large reduction of the rate level due to the cost reduction effect accompanying the improvement in atomic power generation ratio. Outlines are given on the fields relating to general households, business, dwellings, buildings, and industry. 3 figs., 1 tab.

  3. Low levels of maximal aerobic power impair the profile of mood state in individuals with temporal lobe epilepsy

    Directory of Open Access Journals (Sweden)

    Rodrigo Luiz Vancini

    2015-01-01

    Full Text Available Objective To investigate the correlation between cardiorespiratory fitness and mood state in individuals with temporal lobe epilepsy (TLE. Method Individuals with TLE (n = 20 and healthy control subjects (C, n = 20 were evaluated. Self-rating questionnaires were used to assess mood (POMS and habitual physical activity (BAECKE. Cardiorespiratory fitness was evaluated by a maximal incremental test. Results People with TLE presented lower cardiorespiratory fitness; higher levels of mood disorders; and lower levels of vigor when compared to control health subjects. A significant negative correlation was observed between the levels of tension-anxiety and maximal aerobic power. Conclusion Low levels of cardiorespiratory fitness may modify the health status of individuals with TLE and it may be considered a risk factor for the development of mood disorders.

  4. Procedure for conducting probabilistic safety assessment: level 1 full power internal event analysis

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Won Dae; Lee, Y. H.; Hwang, M. J. [and others

    2003-07-01

    This report provides guidance on conducting a Level I PSA for internal events in NPPs, which is based on the method and procedure that was used in the PSA for the design of Korea Standard Nuclear Plants (KSNPs). Level I PSA is to delineate the accident sequences leading to core damage and to estimate their frequencies. It has been directly used for assessing and modifying the system safety and reliability as a key and base part of PSA. Also, Level I PSA provides insights into design weakness and into ways of preventing core damage, which in most cases is the precursor to accidents leading to major accidents. So Level I PSA has been used as the essential technical bases for risk-informed application in NPPs. The report consists six major procedural steps for Level I PSA; familiarization of plant, initiating event analysis, event tree analysis, system fault tree analysis, reliability data analysis, and accident sequence quantification. The report is intended to assist technical persons performing Level I PSA for NPPs. A particular aim is to promote a standardized framework, terminology and form of documentation for PSAs. On the other hand, this report would be useful for the managers or regulatory persons related to risk-informed regulation, and also for conducting PSA for other industries.

  5. Approach to development and use of PSA Level 2 analysis for the Cernavoda nuclear power plant

    International Nuclear Information System (INIS)

    Turcu, I.; Deaconu, R.; Radu, G.

    1998-01-01

    This paper first describes the status of PSA activities for the Cernavoda NPP and the extension of the PSA work to include Level 2 PSA. Important characteristics of this reactor type for Level 2 PSA are outlined. Due to the specific layout of the CANDU reactor the evolution of severe accidents is considerably different to vessel type LWRs. Accidents can be roughly categorized into three categories, ''''severe accidents'''' which lead to the loss of core structural integrity, delayed loss of core structural integrity as a consequence of the loss of heat sinks, and fuel channel failures. The current work for modelling accident progression in the core region is described. The elements for the Level 2 PSA including definition of PDSs, probabilistic containment logic and source term calculation are outlined. It is pointed out that uncertainties have to be considered which are contained in the models to bridge knowledge gaps. For this purpose sensitivity studies will be carried out for key modelling assumptions. (author)

  6. System-Level Design of a 64-Channel Low Power Neural Spike Recording Sensor.

    Science.gov (United States)

    Delgado-Restituto, Manuel; Rodriguez-Perez, Alberto; Darie, Angela; Soto-Sanchez, Cristina; Fernandez-Jover, Eduardo; Rodriguez-Vazquez, Angel

    2017-04-01

    This paper reports an integrated 64-channel neural spike recording sensor, together with all the circuitry to process and configure the channels, process the neural data, transmit via a wireless link the information and receive the required instructions. Neural signals are acquired, filtered, digitized and compressed in the channels. Additionally, each channel implements an auto-calibration algorithm which individually configures the transfer characteristics of the recording site. The system has two transmission modes; in one case the information captured by the channels is sent as uncompressed raw data; in the other, feature vectors extracted from the detected neural spikes are released. Data streams coming from the channels are serialized by the embedded digital processor. Experimental results, including in vivo measurements, show that the power consumption of the complete system is lower than 330 μW.

  7. DC-pass filter design with notch filters superposition for CPW rectenna at low power level

    Science.gov (United States)

    Rivière, J.; Douyère, A.; Alicalapa, F.; Luk, J.-D. Lan Sun

    2016-03-01

    In this paper the challenging coplanar waveguide direct current (DC) pass filter is designed, analysed, fabricated and measured. As the ground plane and the conductive line are etched on the same plane, this technology allows the connection of series and shunt elements to the active devices without via holes through the substrate. Indeed, this study presents the first step in the optimization of a complete rectenna in coplanar waveguide (CPW) technology: key element of a radio frequency (RF) energy harvesting system. The measurement of the proposed filter shows good performance in the rejection of F0=2.45 GHz and F1=4.9 GHz. Additionally, a harmonic balance (HB) simulation of the complete rectenna is performed and shows a maximum RF-to-DC conversion efficiency of 37% with the studied DC-pass filter for an input power of 10 µW at 2.45 GHz.

  8. Design of Mobile Device Display for Nuclear Power Plant Maintenance Considering the Level of Expertise

    International Nuclear Information System (INIS)

    Kim, In; Seong, Poong Hyun

    2009-01-01

    Maintaining and repairing complex technical facilities such as nuclear power plants requires comprehensive knowledge on a broad range of the system, as well as on operational and safety procedures by the performing maintenance personnel. There exists the need to have access to instruction sheets and parameter tables at the work site. This may not be practicable with printed manuals simply due to their increasing bulk. To cope with this situation, fully mobile wirelessly connected (FMWC) information and communication technologies (ICT) are thought to have high potential for improving field maintenance through increased accessibility and availability of critical information needed in on-site reference or decision making. Among many up-todate technologies, the mobile application to the maintenance support system will be proposed in this paper

  9. Investigation of load leveling in Hokuriku Electric Power Co., Inc.; Hokuriku denryoku no fuka heijunka eno torikumi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-08-01

    Hokuriku Electric Power Co., Inc. aims at an around 2% improvement of the load factor up to 2005, by which the quick and proper service and the proposal of load leveling menu are planned. This paper describes an outline of the investigation of load leveling. Various programs have been proposed so that the customers can further shift the load by their consideration. Proposed systems include the time-of-day electricity rate system, the load regulation contract system for industries, the seasonal time-of-day rate system, the electric power system for snowmelt in which the load is dumped at the peak, and the secondary electric power system for snowmelt. Accompanying with the revision of electric utility law, the enlargement of its available time, the price reduction, and the discount rate system for the ice regenerative air conditioners have been provided. For the business activities, a demonstration model house was exhibited to indicate a proper house with local characteristics in Hokuriku district. Furthermore, the spreading activities of regenerative systems and the consulting activities have been positively promoted. 4 figs., 1 tab.

  10. CAMAC and high-level-languages

    International Nuclear Information System (INIS)

    Degenhardt, K.H.

    1976-05-01

    A proposal for easy programming of CAMAC systems with high-level-languages (FORTRAN, RTL/2, etc.) and interpreters (BASIC, MUMTI, etc.) using a few subroutines and a LAM driver is presented. The subroutines and the LAM driver are implemented for PDP11/RSX-11M and for the CAMAC controllers DEC CA11A (branch controller), BORER type 1533A (single crate controller) and DEC CA11F (single crate controller). Mixed parallel/serial CAMAC systems employing KINETIC SYSTEMS serial driver mod. 3992 and serial crate controllers mod. 3950 are implemented for all mentioned parallel controllers, too. DMA transfers from or to CAMAC modules using non-processor-request controllers (BORER type 1542, DEC CA11FN) are available. (orig.) [de

  11. Estimation of Radiofrequency Power Leakage from Microwave Ovens for Dosimetric Assessment at Nonionizing Radiation Exposure Levels

    Directory of Open Access Journals (Sweden)

    Peio Lopez-Iturri

    2015-01-01

    Full Text Available The electromagnetic field leakage levels of nonionizing radiation from a microwave oven have been estimated within a complex indoor scenario. By employing a hybrid simulation technique, based on coupling full wave simulation with an in-house developed deterministic 3D ray launching code, estimations of the observed electric field values can be obtained for the complete indoor scenario. The microwave oven can be modeled as a time- and frequency-dependent radiating source, in which leakage, basically from the microwave oven door, is propagated along the complete indoor scenario interacting with all of the elements present in it. This method can be of aid in order to assess the impact of such devices on expected exposure levels, allowing adequate minimization strategies such as optimal location to be applied.

  12. Highest manageable level of radioactivity in the waste storage facilities of power plants

    International Nuclear Information System (INIS)

    Elkert, J.; Lennartsson, R.

    1991-01-01

    This project presents and discusses an investigation of the highest level of radioactivity possible to handle in the waste storage facilities. The amount of radioactivity, about 0.1% of the fuel inventory, is the same in both of the cases but the amount of water is very different. The hypothetical accident was supposed to be damage of the reactor fuel caused by loss of coolant. (K.A.E.)

  13. LCL filter design for three-phase two-level power factor correction using line impedance stabilization network

    DEFF Research Database (Denmark)

    Kouchaki, Alireza; Nymand, Morten

    2016-01-01

    This paper presents LCL filter design method for three-phase two-level power factor correction (PFC) using line impedance stabilization network (LISN). A straightforward LCL filter design along with variation in grid impedance is not simply achievable and inevitably lead to an iterative solution...... for filter. By introducing of fast power switches for PFC applications such as silicon-carbide, major current harmonics around the switching frequency drops in the region that LISN can actively provide well-defined impedance for measuring the harmonics (i.e. 9 kHz- 30MHz). Therefore, LISN can be replaced...... is derived using the current ripple behavior of converter-side inductor. The grid-side inductor is achieved as a function of LISN impedance to fulfill the grid regulation. To verify the analyses, an LCL filter is designed for a 5 kW SiC-based PFC. The simulation and experimental results support the validity...

  14. A methodology for calculating the levelized cost of electricity in nuclear power systems with fuel recycling

    International Nuclear Information System (INIS)

    De Roo, Guillaume; Parsons, John E.

    2011-01-01

    In this paper we show how the traditional definition of the levelized cost of electricity (LCOE) can be extended to alternative nuclear fuel cycles in which elements of the fuel are recycled. In particular, we define the LCOE for a cycle with full actinide recycling in fast reactors in which elements of the fuel are reused an indefinite number of times. To our knowledge, ours is the first LCOE formula for this cycle. Others have approached the task of evaluating this cycle using an 'equilibrium cost' concept that is different from a levelized cost. We also show how the LCOE implies a unique price for the recycled elements. This price reflects the ultimate cost of waste disposal postponed through the recycling, as well as other costs in the cycle. We demonstrate the methodology by estimating the LCOE for three classic nuclear fuel cycles: (i) the traditional Once-Through Cycle, (ii) a Twice-Through Cycle, and (iii) a Fast Reactor Recycle. Given our chosen input parameters, we show that the 'equilibrium cost' is typically larger than the levelized cost, and we explain why.

  15. Projections of US GHG reductions from nuclear power new capacity based on historic levels of investment

    International Nuclear Information System (INIS)

    Besmann, Theodore M.

    2010-01-01

    Historical rates of capital investment in nuclear plant construction were used as a guide to estimate the potential rate of future capacity introduction. The total linear rate of capital expenditure over the entire period of historical construction from 1964 to 1990 was determined to equal $11.5 billion/yr, and that for the period of peak construction from 1973 to 1985 was computed as $17.9 billion/yr, all in 2004$. These values were used with a variety of current capital cost estimates for nuclear construction to obtain several scenarios for possible future nuclear capacity additions. These values were used to obtain the effect of projected nuclear generating capacity on GHG emissions assuming nuclear would directly replace coal-fired generation. It was concluded that actual reductions in emissions would not be experienced until 2038, yet growth in emissions from electrical production would be slowed through that period. Due to the significant time to introduce large-scale changes in the utility sector, nuclear energy cannot have a dramatic short-term effect on emissions. Nuclear power, however, can have a major positive longer term impact, particularly under more favorable cost and investment conditions.

  16. Electricity consumption by battery-powered consumer electronics: A household-level survey

    International Nuclear Information System (INIS)

    McAllister, J. Andrew; Farrell, Alexander E.

    2007-01-01

    The rapid proliferation of battery-powered consumer electronics and their reliance on inefficient linear transformers has been suggested to be an important part of the rapid growth in 'miscellaneous' electricity consumption in recent years, but detailed data are scarce. We conducted a survey of 34 randomly selected households (HHs) in Northern California about the number, type, and usage of consumer electronics. We also measured the energy consumption of 85 typical consumer electronic devices through various parts of the charge cycle. These primary data were supplemented by national sales information for consumer electronics. Results indicate that typical HHs own 8.4 rechargeable devices, which have a total average demand of 12-17 W per HH. Statewide, this amounts to 160-220 MW of demand, with the peak occurring in the late evening, and about 1600 GWh per year. Only about 15% of this energy is used for battery charging, the rest is lost as waste heat during no-load and charge maintenance periods. Technical options to increase the efficiency of these devices, and the research and policy steps needed to realize these savings are discussed

  17. A Lyapunov Stability Theory-Based Control Strategy for Three-Level Shunt Active Power Filter

    Directory of Open Access Journals (Sweden)

    Yijia Cao

    2017-01-01

    Full Text Available The three-phase three-wire neutral-point-clamped shunt active power filter (NPC-SAPF, which most adopts classical closed-loop feedback control methods such as proportional-integral (PI, proportional-resonant (PR and repetitive control, can only output 1st–25th harmonic currents with 10–20 kHz switching frequency. The reason for this is that the controller design must make a compromise between system stability and harmonic current compensation ability under the condition of less than 20 kHz switching frequency. To broaden the bandwidth of the compensation current, a Lyapunov stability theory-based control strategy is presented in this paper for NPC-SAPF. The proposed control law is obtained by constructing the switching function on the basis of the mathematical model and the Lyapunov candidate function, which can avoid introducing closed-loop feedback control and keep the system globally asymptotically stable. By means of the proposed method, the NPC-SAPF has compensation ability for the 1st–50th harmonic currents, the total harmonic distortion (THD and each harmonic content of grid currents satisfy the requirements of IEEE Standard 519-2014. In order to verify the superiority of the proposed control strategy, stability conditions of the proposed strategy and the representative PR controllers are compared. The simulation results in MATLAB/Simulink (MathWorks, Natick, MA, USA and the experimental results obtained on a 6.6 kVA NPC-SAPF laboratory prototype validate the proposed control strategy.

  18. Comparison of anthropometry, upper-body strength, and lower-body power characteristics in different levels of Australian football players.

    Science.gov (United States)

    Bilsborough, Johann C; Greenway, Kate G; Opar, David A; Livingstone, Steuart G; Cordy, Justin T; Bird, Stephen R; Coutts, Aaron J

    2015-03-01

    The aim of this study was to compare the anthropometry, upper-body strength, and lower-body power characteristics in elite junior, sub-elite senior, and elite senior Australian Football (AF) players. Nineteen experienced elite senior (≥4 years Australian Football League [AFL] experience), 27 inexperienced elite senior (free soft tissue mass [FFSTM], fat mass, and bone mineral content) with dual-energy x-ray absorptiometry, upper-body strength (bench press and bench pull), and lower-body power (countermovement jump [CMJ] and squat jump with 20 kg). A 1-way analysis of variance assessed differences between the playing levels in these measures, whereas relationships between anthropometry and performance were assessed with Pearson's correlation. The elite senior and sub-elite senior players were older and heavier than the elite junior players (p ≤ 0.05). Both elite playing groups had greater total FFSTM than both the sub-elite and junior elite players; however, there were only appendicular FFSTM differences between the junior elite and elite senior players (p squat performance measures (r = 0.33-0.55). Australian Football players' FFSTM are different between playing levels, which are likely because of training and partly explain the observed differences in performance between playing levels highlighting the importance of optimizing FFSTM in young players.

  19. INFLUENCES OF THE PURCHASING POWER CHANGE ON THE EVOLUTION OF THE AGROALIMETARY MARKETS ON EUROPEAN UNION LEVEL

    Directory of Open Access Journals (Sweden)

    Laura Catalina Timiras

    2013-12-01

    Full Text Available This paper aims to identify the manifested connection between the dynamics of the population purchasing power and the dynamic of agroalimentary markets in general as well as by product types on European Union level. Based on the last data supplied by Eurostat 2013, using the specific methods for studying the correlations, we have detected that increases and decreases of the purchasing power generated similar changes on agroalimentary markets level from the point of view of achieved sales in most of the poorer countries of the European Union, but not in those states which got beyond the average gross domestic product per capita of the European Union. This relationship has been noticed only on the agroalimentary markets as a whole (respectively on the amounts spent by the population for purchasing agroalimentary goods, beverages and tobacco, but not on the level of markets of various types of product (“meat and meat products”, “fruit and vegetables”, “dairy produce, eggs and edible oils and fats”, “beverages”, “sugar and chocolate and sugar confectionery”, “tobacco products”.

  20. Assessment of the Current Level of Automation in the Manufacture of Fuel Cell Systems for Combined Heat and Power Applications

    Energy Technology Data Exchange (ETDEWEB)

    Ulsh, M.; Wheeler, D.; Protopappas, P.

    2011-08-01

    The U.S. Department of Energy (DOE) is interested in supporting manufacturing research and development (R&D) for fuel cell systems in the 10-1,000 kilowatt (kW) power range relevant to stationary and distributed combined heat and power applications, with the intent to reduce manufacturing costs and increase production throughput. To assist in future decision-making, DOE requested that the National Renewable Energy Laboratory (NREL) provide a baseline understanding of the current levels of adoption of automation in manufacturing processes and flow, as well as of continuous processes. NREL identified and visited or interviewed key manufacturers, universities, and laboratories relevant to the study using a standard questionnaire. The questionnaire covered the current level of vertical integration, the importance of quality control developments for automation, the current level of automation and source of automation design, critical balance of plant issues, potential for continuous cell manufacturing, key manufacturing steps or processes that would benefit from DOE support for manufacturing R&D, the potential for cell or stack design changes to support automation, and the relationship between production volume and decisions on automation.

  1. State of Level 2 analyses and severe accident management in Spanish nuclear power plants

    International Nuclear Information System (INIS)

    Otero, R.

    1998-01-01

    The state of the PSA/IPE studies in the Spanish NPPs is presented in this report, as well as the plans to implement the severe accident management strategy both in the Spanish BWRs and PWRs. First, the Spanish LWRs are introduced, and the scope of the IPE analyses required by the Spanish Regulatory Commission (CSN) is given. The general overview is completed with the current degree of development for the IPE studies in each plant. In the second part the methods and tools are shown which are used by the Spanish plants to develop their Level 2 analysis. The different strategies for severe accident management adopted by the BWPs and PWRs in Spain are also outlined. The sources and implementation of the Severe Accident Guidelines (SAG) are described. More detail is given in the following chapters to the containment analysis of Trillo (PWR, KWU design) and Cofrentes (BWR/6, GE design) NPPs, whose development is being carried out by IBERDROLA. The analysis which has been performed up to date for Trillo is limited to the Plant Damage State (PDS) definition. However, the main phenomena challenging its containment performance have been identified, and they are summarized here. The Level 2 analysis for Cofrentes is comparatively more developed. The main phenomena and the key equipment affecting its containment behaviour are presented. Finally the conclusions of this report are elaborated. (author)

  2. Generic conditional clearance for very low level active charcoal generated in nuclear power plant operation

    International Nuclear Information System (INIS)

    Gomez Perales, J. J.; Burgos Gallego, J.; Alvarez Mir, F.; Luis de Diego, J.; Adrada Garcia, J.

    1998-01-01

    This report proposes a generic conditional exemption to the very low level active charcoal generated in the operation of a NPP. The project has been developed in two parts: a common one (applied to the stream to be exempted) and a specific one (specific to the NPP that fulfills already the common part requirements). The common project specifies the methodology and the disposal options. It provides derived exemption levels and maximum amount of activity the exemption of which be feasible, demonstrating the viability of their conventional management. The specific project of each NPP will develop the amount of waste to be managed and other details that supplement the previous project, adjusting to the methodology and disposal options in the common project. The proposed management suggestion consists in burning the waste in a coal-burning plant and disposing of the scum in a controlled landfill. The resultant radiological dose is considered negligible according to the document Safety Series N 89 of the IAEA. The calculation of the radiological dose associated to several stages has been carried out using the IMPACTS-BRC code, contained in NUREG/CR-3585 and NUREG/5517. The methodology used in the radiological dose evaluation is as recommended in the Safety Guide n. 7.8 of the Spanish Nuclear Safety Council. (Author)

  3. Techno-economic analysis of concentrated solar power plants in terms of levelized cost of electricity

    Science.gov (United States)

    Musi, Richard; Grange, Benjamin; Sgouridis, Sgouris; Guedez, Rafael; Armstrong, Peter; Slocum, Alexander; Calvet, Nicolas

    2017-06-01

    Levelized Cost of Electricity (LCOE) is an important metric which provides one way to compare the economic competitiveness of different electricity generation systems, calculated simply by dividing lifetime costs by lifetime production. Hidden behind the simplicity of this formula are various assumptions which may significantly alter results. Different LCOE studies exist in the literature, although their assumptions are rarely explicitly stated. This analysis gives all formulas and assumptions which allow for inter-study comparisons. The results of this analysis indicate that CSP LCOE is reducing markedly over time and that given the right location and market conditions, the SunShot 6¢/kWh 2020 target can be reached. Increased industrial cooperation is needed to advance the CSP market and continue to drive down LCOE. The results also indicate that there exist a country and technology level learning effect, either when installing an existing CSP technology in a new country or when using a new technology in an existing CSP country, which seems to impact market progress.

  4. M4D: a powerful tool for structured programming at assembly level for MODCOMP computers

    International Nuclear Information System (INIS)

    Shah, R.R.; Basso, R.A.J.

    1984-04-01

    Structured programming techniques offer numerous benefits for software designers and form the basis of the current high level languages. However, these techniques are generally not available to assembly programmers. The M4D package was therefore developed for a large project to enable the use of structured programming constructs such as DO.WHILE-ENDDO and IF-ORIF-ORIF...-ELSE-ENDIF in the assembly code for MODCOMP computers. Programs can thus be produced that have clear semantics and are considerably easier to read than normal assembly code, resulting in reduced program development and testing effort, and in improved long-term maintainability of the code. This paper describes the M4D structured programming tool as implemented for MODCOMP'S MAX III and MAX IV assemblers, and illustrates the use of the facility with a number of examples

  5. The biotest basin of the Forsmark nuclear power plant, Sweden. An experiment on the ecosystem level

    International Nuclear Information System (INIS)

    Grimaas, U.

    1979-01-01

    Biotope models of various sizes and enclosed waters in connection with radionuclide release constitute important tools for radioecological experiments, representing an intermediate step between field and laboratory conditions. The biotest basin at Forsmark is especially constructed for investigations on the effects of radioactivity and heat on a brackish water ecosystem. The basin encloses a water area of 1km 2 in the outer archipelago of the region and is fed with cooling water and released radionuclides by a discharge tunnel. The quantities of the discharges into the basin are adjustable. The biotest experiment permits a quantification of the retention and transport of radionuclides at the various trophic levels. Of special value is the possibility to work with known populations of fish. The approach has the advantage of experimental ecology - the control of important parameters - under the impact of all environmental factors in a complete ecosystem. (author)

  6. Procedures for conducting probabilistic safety assessments of nuclear power plants (Level 1)

    International Nuclear Information System (INIS)

    1992-01-01

    This report provides guidance for conducting a Level 1 of probabilistic safety assessment (PSA), that is a PSA concerned with events leading to core damage. The scope of this report is confined to internal initiating events (excluding internal fires and floods). A particular aim is to promote a standardized framework, terminology and form of documentation for PSAs so as to facilitate external review of the results of such studies. The report is divided into the following major sections: management and organization; identification of sources of radioactive releases and accident initiators; accident sequence modelling; data assessment and parameter estimation; accident sequence quantification; documentation of the analysis: display and interpretation of result. 45 refs, 7 figs, 23 tabs

  7. Application of Integrated Verification Approach to FPGA-based Safety-Critical I and C System of Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Ibrahim; Heo, Gyunyoung [Kyunghee Univ., Yongin (Korea, Republic of); Jung, Jaecheon [KEPCO, Ulsan (Korea, Republic of)

    2016-10-15

    Safety-critical instrumentation and control (I and C) system in nuclear power plant (NPP) implemented on programmable logic controllers (PLCs) plays a vital role in safe operation of the plant. The challenges such as fast obsolescence, the vulnerability to cyber-attack, and other related issues of software systems have currently led to the consideration of field programmable gate arrays (FPGAs) as an alternative to PLCs because of their advantages and hardware related benefits. Generally in FPGA design verification, the designers make use of verification techniques by writing the test benches which involved various stages of verification activities of register-transfer level (RTL), gate-level, and place and route. Writing the test benches is considerably time consuming and require a lot of efforts to achieve a satisfied desire results. Furthermore, performing the verification at each stage is a major bottleneck and demanded much activities and time. In addition, verification is conceivably, the most difficult and complicated aspect of any design. Therefore, in view of these, this work applied an integrated verification approach to the verification of FPGA-based I and C system in NPP that simultaneously verified the whole design modules using MATLAB/Simulink HDL Co-simulation models. Verification is conceivably, the most difficult and complicated aspect of any design, and an FPGA design is not an exception. Therefore, in this work, we introduced and discussed how an application of integrated verification technique to the verification and testing of FPGA-based I and C system design in NPP can facilitate the verification processes, and verify the entire design modules of the system simultaneously using MATLAB/Simulink HDL co-simulation models. In conclusion, the results showed that, the integrated verification approach through MATLAB/Simulink models, if applied to any design to be verified, could speed up the design verification and reduce the V and V tasks.

  8. Application of Integrated Verification Approach to FPGA-based Safety-Critical I and C System of Nuclear Power Plant

    International Nuclear Information System (INIS)

    Ahmed, Ibrahim; Heo, Gyunyoung; Jung, Jaecheon

    2016-01-01

    Safety-critical instrumentation and control (I and C) system in nuclear power plant (NPP) implemented on programmable logic controllers (PLCs) plays a vital role in safe operation of the plant. The challenges such as fast obsolescence, the vulnerability to cyber-attack, and other related issues of software systems have currently led to the consideration of field programmable gate arrays (FPGAs) as an alternative to PLCs because of their advantages and hardware related benefits. Generally in FPGA design verification, the designers make use of verification techniques by writing the test benches which involved various stages of verification activities of register-transfer level (RTL), gate-level, and place and route. Writing the test benches is considerably time consuming and require a lot of efforts to achieve a satisfied desire results. Furthermore, performing the verification at each stage is a major bottleneck and demanded much activities and time. In addition, verification is conceivably, the most difficult and complicated aspect of any design. Therefore, in view of these, this work applied an integrated verification approach to the verification of FPGA-based I and C system in NPP that simultaneously verified the whole design modules using MATLAB/Simulink HDL Co-simulation models. Verification is conceivably, the most difficult and complicated aspect of any design, and an FPGA design is not an exception. Therefore, in this work, we introduced and discussed how an application of integrated verification technique to the verification and testing of FPGA-based I and C system design in NPP can facilitate the verification processes, and verify the entire design modules of the system simultaneously using MATLAB/Simulink HDL co-simulation models. In conclusion, the results showed that, the integrated verification approach through MATLAB/Simulink models, if applied to any design to be verified, could speed up the design verification and reduce the V and V tasks

  9. Disposal of high-level waste from nuclear power plants in Denmark. v.3

    International Nuclear Information System (INIS)

    1981-01-01

    The present report deals with material testing as part of the investigations regarding a repository for high-level waste in a salt dome. It is volume 3 of five volumes that together constitute the final report of the Danish utilities' salt dome investigations. The material testing programme chiefly comprised laboratory investigations and analyses of material samples, partly obtained from the salt dome in question and partly from the overlying geological formation. The test programme was fully completed for Eslev salt dome on Mors. Chemical analyses and mineralogical investigations were carried out in order to determine the type and extent of the impurities confined in the rock salt. Moreover, a programme was carried out to investigate the water content of the salt. Temperature conditions around a repository, the strenght and creep properties of the salt were investigated in order to determine whether drill holes, shafts and mine galleries could be constructed and maintained intact within the period of time required to complete the disposal of high-level waste. Chemical analysis were carried out in order to determine which substances are found dissolved in the water contained by the geological formation overlying the salt dome, as well as chemical/physical investigations regarding the water content, porosity, velocity of a possible leak of radioactive waste products, etc. Materials that would be introduced into a repository were studied with regard to their corrosion resistance in the salt environment. Concrete materials were investigated and characterized for their use in the final sealing of the access routes to the repository through the geological formation. (BP)

  10. Approach to load leveling in Kansai Electric Power Co. Inc.; Kansai Denryoku no fuka heijunka eno torikumi

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-09-01

    This paper presents an electric hot-water heater and ice storage air conditioning system as systems to be recommended for load leveling. Electric hot-water heater is featured by safety, cleanliness, silence and convenience because of no use of fire. Its electricity charge is only 7.15 yen/kWh less than 1/3 of that for ordinary homes because of use of midnight power. Mainly used MPU-control type electric hot-water heater is more economical because of a 15% discount system. Ice storage air conditioning system is operated in the daytime using ice made by midnight power. It is featured by reduction of facility and installation costs due to the small capacity of heat source equipment, use of inexpensive midnight power, and reduction of running cost due to small contract demand. However, since an ice storage air conditioning system is in the initial stage of diffusion, its initial cost is expensive as compared with conventional non-heat storage air conditioning systems, remaining the issue of cost reduction. 3 figs., 1 tab.

  11. THE SECURITY AND CRITICAL LEVELS OF PHYSICAL ACTIVITY FOR TRAINED AND UNTRAINED PERSONS IN MUSCLE PERFORMANCE POWER ORIENTATION.

    Science.gov (United States)

    Chernozub, A A

    The paper studied the problem of finding the optimal methodology for determining the safety and critical load conditions for the body trained and untrained people in the process of training the force pool. It was found that for trained individuals who have a sufficient level of adaptation to the power load, the use of “standard” modes of operation in the course of employment by fitness power safely. However, the problematic issue is that to the untrained troops, it is almost impossible to determine the safe load parameters using conventional techniques, which are mainly used in cyclic sports. Thus, the solution to this problem lies in the fact that using the integral method for estimating the value of power loads and a computer program for determining the relative weight of the index weights, safety and critical load parameters were calculated for untrained persons. At the same time, studied the biochemical parameters of blood (testosterone, cortisol, and lactate dehydrogenase activity) fixed after exercise, compared with the state of rest, confirmed our calculations clearly enough.

  12. System Level Design of Reconfigurable Server Farms Using Elliptic Curve Cryptography Processor Engines

    Directory of Open Access Journals (Sweden)

    Sangook Moon

    2014-01-01

    Full Text Available As today’s hardware architecture becomes more and more complicated, it is getting harder to modify or improve the microarchitecture of a design in register transfer level (RTL. Consequently, traditional methods we have used to develop a design are not capable of coping with complex designs. In this paper, we suggest a way of designing complex digital logic circuits with a soft and advanced type of SystemVerilog at an electronic system level. We apply the concept of design-and-reuse with a high level of abstraction to implement elliptic curve crypto-processor server farms. With the concept of the superior level of abstraction to the RTL used with the traditional HDL design, we successfully achieved the soft implementation of the crypto-processor server farms as well as robust test bench code with trivial effort in the same simulation environment. Otherwise, it could have required error-prone Verilog simulations for the hardware IPs and other time-consuming jobs such as C/SystemC verification for the software, sacrificing more time and effort. In the design of the elliptic curve cryptography processor engine, we propose a 3X faster GF(2m serial multiplication architecture.

  13. Impact of Different Tidal Volume Levels at Low Mechanical Power on Ventilator-Induced Lung Injury in Rats

    Directory of Open Access Journals (Sweden)

    Lillian Moraes

    2018-04-01

    Full Text Available Tidal volume (VT has been considered the main determinant of ventilator-induced lung injury (VILI. Recently, experimental studies have suggested that mechanical power transferred from the ventilator to the lungs is the promoter of VILI. We hypothesized that, as long as mechanical power is kept below a safe threshold, high VT should not be injurious. The present study aimed to investigate the impact of different VT levels and respiratory rates (RR on lung function, diffuse alveolar damage (DAD, alveolar ultrastructure, and expression of genes related to inflammation [interleukin (IL-6], alveolar stretch (amphiregulin, epithelial [club cell secretory protein (CC16] and endothelial [intercellular adhesion molecule (ICAM-1] cell injury, and extracellular matrix damage [syndecan-1, decorin, and metalloproteinase (MMP-9] in experimental acute respiratory distress syndrome (ARDS under low-power mechanical ventilation. Twenty-eight Wistar rats received Escherichia coli lipopolysaccharide intratracheally. After 24 h, 21 animals were randomly assigned to ventilation (2 h with low mechanical power at three different VT levels (n = 7/group: (1 VT = 6 mL/kg and RR adjusted to normocapnia; (2 VT = 13 mL/kg; and 3 VT = 22 mL/kg. In the second and third groups, RR was adjusted to yield low mechanical power comparable to that of the first group. Mechanical power was calculated as [(ΔP,L2/Est,L/2]× RR (ΔP,L = transpulmonary driving pressure, Est,L = static lung elastance. Seven rats were not mechanically ventilated (NV and were used for molecular biology analysis. Mechanical power was comparable among groups, while VT gradually increased. ΔP,L and mechanical energy were higher in VT = 22 mL/kg than VT = 6 mL/kg and VT = 13 mL/kg (p < 0.001 for both. Accordingly, DAD score increased in VT = 22 mL/kg compared to VT = 6 mL/kg and VT = 13 mL/kg [23(18.5–24.75 vs. 16(12–17.75 and 16(13.25–18, p < 0.05, respectively]. VT = 22 mL/kg was associated with higher

  14. Low-level dry active waste management planning for Calvert Cliffs Nuclear Power Plant

    International Nuclear Information System (INIS)

    Butler, C.N.; Feizollani, F.; Jarboe, Th.B.

    1984-01-01

    To offset the rising cost of low-level radioactive waste disposal and to provide contingency measures for disposal space unavailability after January 1, 1986, Baltimore Gas and Electric (BG and E) has undertake efforts to establish a long-term waste management program. This plan, which was developed after detailed study of a number of options, consists of four elements: management of dry active wastes; implementation of 10CFR61 requirements; storage of process wastes; and enhancement of liquid/solid waste systems and equipment performance. Each element was scheduled for implementation in accordance with an established set of priorities. Accordingly, detailed engineering for implementation of the first two elements was initiated in December of 1982. This paper focuses on BGandE's experience in implementation of the first element o the program, i.e., the management of dry active waste (DAW). DAW is managed by providing a new buildin dedicated to its handling, processing, volume-reduction, and storage. This building, which is equipped with state-of-the-art decontamination and processing techniques, allows for implementation of waste minimization and for interim storage of DAW in a safe and cost effective manner

  15. Compatibility of cement with low and medium level wastes generated at nuclear power plants

    International Nuclear Information System (INIS)

    De Angelis, G.

    1987-01-01

    The incorporation of low- and medium level wastes in cement can give rise to serious problems due to the interaction between radwastes and cement components. Some troubles can occur during the first stages of the cementation process while deleterious phenomena come into evidence in the medium and long term. With the aim to improve the quality of the final waste forms a pretreatment of the waste streams is often necessary, as well as the addition of special agents to the cement matrix. The prediction of the long-term behaviour of the final products is of main importance in this research field. To this purpose some accelerated tests have been proposed, but much effort should be further devoted to the comprehension of the waste/matrix interaction. In this paper the principal waste streams are reviewed together with the possible remedies which seem to be more suitable for their cementation. Thus the qpportunity of separatly handling and solidifying different types of waste is once more supported

  16. Party Organizational Change: Formal Distribution of Power between National and Regional Levels in Italian Political Parties (1991-2012

    Directory of Open Access Journals (Sweden)

    Enrico Calossi

    2015-03-01

    Full Text Available In the last 20 years an increasing number of scholars have centred their attention on the relationships between party national structures and party sub-national branches. A relevant part of the specialized literature has interpreted party change as the by-product of the denationalization of party politics. The aim of this contribution is to investigate to what extent eight relevant Italian parties have followed patterns of organizational change, after the reforms of the municipal, provincial and regional election sys-tems; and the process of devolution of administrative powers begun during the Nineties. By focusing on two analytical dimensions (the level of involvement and the level of autonomy of party regional units, we analyse diachronically continuity and change in party formal organization, through an in-depth analysis of the statutes adopted from 1992 to 2012

  17. Low-level radioactive waste from nuclear power generating stations: Characterization, classification and assessment of activated metals and waste streams

    International Nuclear Information System (INIS)

    Thomas, V.W.; Robertson, D.E.; Thomas, C.W.

    1993-02-01

    Since the enactment of 10 CFR Part 61, additional difficult-to-measure long-lived radionuclides, not specified in Tables 1 2 of Part 61, have been identified (e.g., 108m Ag, 93 Mo, 36 Cl, 10 Be, 113m Cd, 121m Sn, 126 Sn, 93m Nb) that may be of concern in certain types of waste. These nuclides are primarily associated with activated metal and perhaps other nuclear power low-level waste (LLW) being sent to disposal facilities. The concentration of a radionuclide in waste materials is normally determined by direct measurement or by indirect calculational methods, such as using a scaling factor to relate inferred concentration of a difficult-to-measure radionuclide to another that is easily measured. The total disposal site inventory of certain difficult-to-measure radionuclides (e.g., 14 C, 129 I, and 99 Tc) often control the total quantities of radioactive waste permitted in LLW burial facilities. Overly conservative scaling factors based on lower limits of detection (LLD), often used in the nuclear power industry to estimate these controlling nuclides, could lead to premature closure of a disposal facility. Samples of LLW (Class B and C activated metals [AM] and other waste streams) are being collected from operating nuclear power stations and analyzed for radionuclides covered in 10 CFR Part 61 and the additional difficult-to-measure radionuclides. This analysis will enhance the NRC's understanding of the distribution and projected quantities of radionuclides within AM and LLW streams from commercial nuclear power stations. This research will also provide radiological characterization of AM specimens for others to use in leach-rate and lysimeter experiments to determine nuclide releases and subsequent movement in natural soil environments

  18. Direct integration of intensity-level data from Affymetrix and Illumina microarrays improves statistical power for robust reanalysis

    Directory of Open Access Journals (Sweden)

    Turnbull Arran K

    2012-08-01

    Full Text Available Abstract Background Affymetrix GeneChips and Illumina BeadArrays are the most widely used commercial single channel gene expression microarrays. Public data repositories are an extremely valuable resource, providing array-derived gene expression measurements from many thousands of experiments. Unfortunately many of these studies are underpowered and it is desirable to improve power by combining data from more than one study; we sought to determine whether platform-specific bias precludes direct integration of probe intensity signals for combined reanalysis. Results Using Affymetrix and Illumina data from the microarray quality control project, from our own clinical samples, and from additional publicly available datasets we evaluated several approaches to directly integrate intensity level expression data from the two platforms. After mapping probe sequences to Ensembl genes we demonstrate that, ComBat and cross platform normalisation (XPN, significantly outperform mean-centering and distance-weighted discrimination (DWD in terms of minimising inter-platform variance. In particular we observed that DWD, a popular method used in a number of previous studies, removed systematic bias at the expense of genuine biological variability, potentially reducing legitimate biological differences from integrated datasets. Conclusion Normalised and batch-corrected intensity-level data from Affymetrix and Illumina microarrays can be directly combined to generate biologically meaningful results with improved statistical power for robust, integrated reanalysis.

  19. Alpha spectral power and coherence in the patients with mild cognitive impairment during a three-level working memory task

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Objective: The functional relationship between calculated alpha band spectral power and inter-/intra-hemispheric coherence during a three-level working memory task of patients with mild cognitive impairment (MCI) was investigated. Methods:Subjects included 35 MCI patients according to the DSM-Ⅳ criteria (mean age: 62.3, SD: 6.5) and 34 healthy controls (mean age:57.4, SD: 4.0) were selected from the community at large. All subjects performed a simple calculation and recall task with three levels of working memory load while electroencephalograph (EEG) signal was recorded. The spectral EEG power was computed over alphal (8.0~10.0 Hz) and alpha2 (10.5~13.0 Hz) frequency bands and was compared between rest stage and working memory processing stage by two-way ANOVA. Post hoc testing analyzed the differences between each two levels of working memory load during task processing. The inter-hemisphere EEG coherence of frontal (F3-F4), central (C3-C4), parietal (P3-P4), temporal (T5-T6) as well as occipital (O1-O2) was compared between MCI patients and normal controls. The EEG signals from F3-C3,F4-C4, C3-P3, C4-P4, P3-O1, P4-O2, T5-C3, T6-C4, T5-P3 and T6-P4 electrode pairs resulted from the intra-hemispheric action for alphal and alpha2 frequency bands. Result: There was significantly higher EEG power from MCI patients than from normal controls both at rest and during working memory processing. Significant differences existed between rest condition and three-level working memory tasks (P<0.001). The inter- and intra-hemispheric coherence during working memory tasks showed a "drop to rise" tendency compared to that at rest condition. There was significantly higher coherence in MCI patients than in the controls.When task difficulties increased, the cortical connectivity of intra-hemispheric diminished while the inter-hemispheric connectivity dominantly maintained the cognitive processing in MCI patients. Conclusion: The results of the present study indicate that the

  20. Fuzzy logic controller architecture for water level control in nuclear power plant steam generator using ANFIS training method

    International Nuclear Information System (INIS)

    Vosoughi, Naser; Ekrami, AmirHasan; Naseri, Zahra

    2003-01-01

    Since suitable control of water level can greatly enhance the operation of a power station, a fuzzy logic controller is applied to control the steam generator water level in a pressurized water reactor. The method does not require a detailed mathematical model of the object to be controlled. It is shown that two inputs, a single output and the least number of rules (9 rules) are considered for a controller, and the ANFIS training method is employed to model functions in a controlled system. By using ANFIS training method, initial membership functions will be trained and appropriate functions are generated to control water level inside the steam generator while using the stated rules. The proposed architecture can construct an input-output mapping based on both human knowledge (in the from of fuzzy if - then rules) and stipulated input-output data. This fuzzy logic controller is applied to the steam generator level control by computer simulations. The simulation results confirm the excellent performance of this control architecture in compare with a well-turned PID controller. (author)

  1. The influence of single whole body cryostimulation treatment on the dynamics and the level of maximal anaerobic power.

    Science.gov (United States)

    Klimek, Andrzej T; Lubkowska, Anna; Szyguła, Zbigniew; Frączek, Barbara; Chudecka, Monika

    2011-06-01

    The objective of this work was to determine the dynamics of maximal anaerobic power (MAP) of the lower limbs, following a single whole body cryostimulation treatment (WBC), in relation to the temperature of thigh muscles. The subjects included 15 men and 15 women with an average age (± SD) of 21.6 ± 1.2 years. To evaluate the level of anaerobic power, the Wingate test was applied. The subjects were submitted to 6 WBC treatments at -130°C once a day. After each session they performed a single Wingate test in the 15, 30, 45, 60, 75 and 90th min after leaving the cryogenic chamber. The order of the test was randomized. All Wingate tests were preceded by an evaluation of thigh surface temperature with the use of a thermovisual camera. The average thigh surface temperature (T(av)) in both men and women dropped significantly after the whole body cryostimulation treatment, and next increased gradually. In women T(av) remained decreased for 75 min, whereas in men it did not return to the basal level until 90th min. A statistically insignificant decrease in MAP was observed in women after WBC. On the contrary, a non-significant increase in MAP was observed in men. The course of changes in MAP following the treatment was similar in both sexes to the changes in thigh surface temperature, with the exception of the period between 15th and 30th min. The shorter time to obtain MAP was observed in women till 90th min and in men till 45 min after WBC compared to the initial level. A single whole body cryostimulation may have a minor influence on short-term physical performance of supramaximal intensity, but it leads to improvement of velocity during the start as evidenced by shorter time required to obtain MAP.

  2. Peer review of the Barselina Level 1 probabilistic safety assessment of the Ignalina Nuclear Power Plant, Unit 2

    International Nuclear Information System (INIS)

    McKay, S.L.; Coles, G.A.

    1995-01-01

    The Barselina Project is a Swedish-funded, cooperative effort among Lithuania, Russia and Sweden to transfer Western probabilistic safety assessment (PSA) methodology to the designers/operators of Ignalina Nuclear Power Plant (INPP). The overall goal is to use the PSA as a tool for assessing plant operational safety. The INPP is a two-unit, Former Soviet Union-designed nuclear facility located in Lithuania. The results of this PSA will ultimately be used to identify plant-specific improvements in system design and the conduct of facility operations, allowing improved operational safety. Pacific Northwest Laboratory (PNL) was asked to perform an independent expert peer review of the Barselina PSA. This report documents the findings of this review. This review, financed with nuclear safety assistance funds through the US Agency for International Development (USAID) and the US Department of Energy (DOE), satisfies Task II of the PNL peer review of the Barselina project. The objective is to provide an independent, in-proce ss examination of the Barselina Level 1 PSA of Ignalina Nuclear Power Plant, Unit 2. The review consisted of an investigation of the project documentation, interviews, and extensive discussions with the PSA staff during critical stages of the project. PNL assessed the readability, completeness, consistency, validity, and applicability of the PSA. The major aspects explored were its purpose, major assumptions, analysis/modeling, results, and interpretation. It was not within the scope of this review to perform plant walkdowns or to review material other than the PSA documentation

  3. Radioactivity level of airplane to Guangzhou Baiyun international airport during the Fukushima Daiichi nuclear power plant accident

    International Nuclear Information System (INIS)

    Song Haiqing; Chen Wentao; Cheng Xiaobo; Liao Tong; Deng Fei; Chen Fuliang; Zhang Yanjin; Li Lingjuan; Liang Guiyuan; Wu Guibiao

    2014-01-01

    The radioactivity level of airplanes to Guangzhou Baiyun International Airport (GBIAC) during the Fukushima Daiichi nuclear power plant accident was monitored by Guangdong Environmental Radiation Monitoring Center (GERC) on March 15 and 16, 2011. The artificial radionuclide "1"3"1I, "1"3"4Cs, "1"3"7Cs, "l"3"6Cs, "1"3"2I, "1"3"2Te were detected in the wipe samples of the outer surface of airplanes from Japan to GBIAC. The radioactivity ration of "1"3"7Cs/"1"3"4Cs was calculated as (1.12 ± 0.06) in the wipe samples, which similar to the result in the wipe sample of the outer surface of airplanes from Japan to Hangzhou airport obtained by Zhejiang Province Environmental Radiation Monitoring Center (l.lO ± 0.08), but slightly higher than results in the aerosol monitoring at Guangzhou (0.99 ± 0.30) and Shenzhen (0.94 ± 0.30) by GERC, the data (0.83) published by Japan Nuclear and Industrial Safety Agency (NISA) and the result (1.00 ± 0.13) measured by Tokyo Electric Power Company. A slight radioactive contamination was detected on the surface of outer airplanes and internal cabin. The practice suggested that the wipe sample of the outer surface of airplane was a fast , simple and sensitive approach for emergency monitoring of radioactive contamination. (authors)

  4. Determination of the excess of reactivity in a nuclear configuration and its influence on the power level

    International Nuclear Information System (INIS)

    Zuniga, Agustin; Tapia, Jose

    2014-01-01

    This work presents experimental results which show that the critical position of a given nuclear configuration changes with the reactor power (expressed by the current measurement). Thus, if the current is 0.6 x 10 -11 A (1 W), then the critical position is, BC1 = 0.0 % while 0.6 x 10 -9 A (100 W), BC1= 46.5 %. The difference is apparent because under a current of 10 -10 A, the reactivity is not significant. Therefore, it is recommended that for reactors like the RP-10 with a lot of neutrons at the 'background' level, the excess reactivity must be measured in current as 0.6 x 10 -9 A (100 W) not less. Finally, the excess of reactivity for the N o 42 configuration was determined, which was 3032 pcm with uncertainty less than 1 %. (authors).

  5. Options for the ultimate storage of low and medium level radioactive wastes produced at Laguna Verde nuclear power plant

    International Nuclear Information System (INIS)

    Emeterio, Miguel

    1991-01-01

    The devoted time and still to be expend in prepare, execute and teach permanent and safe solutions to the problem of the evaluation of radioactive wastes reflects the political, economic and environmental importance with respect to public health and safety invested in this task, as well as, its technological challenges. In the case of Laguna Verde nuclear power plant, its low and medium level radioactive wastes are stored in the beginning in a temporal store with a capacity of 2000 m 3 sufficient to four years of normal operation; according to what it is necessary to select one of different ways of waste storage. Different technologies has been evaluated and the preliminary conclusion is that for Mexico the more feasible way to store radioactive wastes is in tumulus (Author)

  6. Unified System-Level Modeling of Intermittent Renewable Energy Sources and Energy Storage for Power System Operation

    DEFF Research Database (Denmark)

    Heussen, Kai; Koch, Stephan; Ulbig, Andreas

    2011-01-01

    The system-level consideration of inter- mittent renewable energy sources and small-scale en- ergy storage in power systems remains a challenge as either type is incompatible with traditional operation concepts. Non-controllability and energy-constraints are still considered contingent cases...... in market-based operation. The design of operation strategies for up to 100 % renewable energy systems requires an explicit consideration of non-dispatchable generation and stor- age capacities, as well as the evaluation of operational performance in terms of energy eciency, reliability, environmental...... impact and cost. By abstracting from technology-dependent and physical unit properties, the modeling framework presented and extended in this pa- per allows the modeling of a technologically diverse unit portfolio with a unied approach, whilst establishing the feasibility of energy-storage consideration...

  7. A stationary reference frame current control for a multi-level H-bridge power converter for universal and flexible power management in future electricity network

    DEFF Research Database (Denmark)

    Ciobotaru, Mihai; Iov, Florin; Zanchetta, Pericle

    2008-01-01

    converters for grid connection of renewable sources will be needed. These power converters must be able to provide intelligent power management as well as ancillary services. This paper assesses a control method based on the stationary reference frame with Proportional-Resonant current controllers...

  8. Predictive Current Control of a 7-level AC-DC back-to-back Converter for Universal and Flexible Power Management System

    DEFF Research Database (Denmark)

    Bifaretti, Steffano; Zanchetta, Pericle; Iov, Florin

    2008-01-01

    The paper proposes a novel power conversion system for Universal and Flexible Power Management (UNIFLEX-PM) in Future Electricity Network. Its structure is based on a back-to-back three-phase AC-DC 7-level converter; each AC side is connected to a different PCC, representing the main grid and....../or various distributed generation systems. Effective and accurate power flow control is demonstrated through simulation in Matlab- Simulink environment on a model based on a two-port structure and using a Predictive Control technique. Control of different Power flow profiles has been successfully tested...

  9. Serial powering optimization for CMS and ATLAS pixel detectors within RD53 collaboration for HL-LHC: system level simulations and testing

    CERN Document Server

    Orfanelli, Stella; Hamer, Matthias; Hinterkeuser, F; Karagounis, M; Pradas Luengo, Alvaro; Marconi, Sara; Ruini, Daniele

    2017-01-01

    Serial powering is the baseline choice for low mass power distribution for the CMS and ATLAS HL-LHC pixel detectors. Two 2.0 A Shunt-LDO regulators are integrated in a prototype pixel chip implemented in 65-nm CMOS technology and used to provide constant supply voltages to its power domains from a constant input current. Performance results from testing prototype Shunt-LDO regulators are shown, including their behaviour after x-ray irradiation. The system level simulation studies, which had been performed with a detailed regulator design in a serially powered topology, have been validated.

  10. Manufacturing at industrial level of UO2 pellets for the fuel elements of the Atucha I Nuclear Power Plant

    International Nuclear Information System (INIS)

    Dyment, I.G.; Noguera Rojas, Francisco

    1982-01-01

    The interest to produce fuel elements within a policy of self sufficiency arose with the installation of Atucha I. The first steps towards this goal consisted in processing the uranium oxide, transforming it into fuel pellets of high density. The developments towards the fabrication of said pellets, performed by CNEA since 1968, first at a laboratory level and afterwards on an industrial scale, allowed CNEA to obtain its own technological capability to produce 400 kg of UO 2 per day. The fuel pellets manufacturing method developed by CNEA is a powder-metallurgical process, which, besides conventional equipment, involves the use of special equipment that required the performance of systematic testing programmes, as well as special training at operational level. The developed processes respond to a modern and advanced technology. A general scheme of the process, starting with a directly sinterable UO 2 powder, is described, including compacting of the powder into pellets, sintering, control of the temperature in the sintering and reduction zones and of the time of permanence in both zones, and cylindric rectifying of the pellets. During the whole process, specialized personnel controls the operations, after which the material is released by the Quality Control Department. The national contribution to the manufacturing technology of the pellets for fuel elements of power and research reactors was of 100%. (M.E.L.) [es

  11. Level 1 probabilistic risk assessment of low power and shutdown operations at a PWR: Phase 2 results

    International Nuclear Information System (INIS)

    Chu, T.L.; Bozoki, G.; Kohut, P.; Musicki, Z.; Wong, S.M.; Yang, J.; Hsu, C.J.; Diamond, D.J.; Su, R.F.; Holmes, B.; Siu, N.; Bley, D.; Lin, J.

    1992-01-01

    As a result of the Chernobyl accident and other precursor events (e.g., Diablo Canyon), the US Nuclear Regulatory Commission's (NRC's) Office of Nuclear Regulatory Research (RES) initiated an extensive project during 1989 to carefully examine the potential risks during Low Power and Shutdown (LP ampersand S) operations. Shortly after the program began, an event occurred at the Vogtle plant during shutdown, which further intensified the effort of the LP ampersand S program. In the LP ampersand S program, one pressurized water reactor (PWR), Surry, and one boiling water reactor (BWR), Grand Gulf, were selected, mainly because they were previously analyzed in the NUREG-1150 Study. The Level-1 Program is being performed in two phases. Phase 1 was dedicated to performing a coarse screening level-1 analysis including internal fire and flood. A draft report was completed in November, 1991. In the phase 2 study, mid-loop operations at the Surry plant were analyzed in detail. The objective of this paper is to present the approach of the phase 2 study and the preliminary results and insights

  12. IFE chamber dry wall materials response to pulsed X-rays and ions at power-plant level fluences

    Energy Technology Data Exchange (ETDEWEB)

    Renk, T.J. E-mail: tjrenk@sandia.gov; Olson, C.L.; Tanaka, T.J.; Ulrickson, M.A.; Rochau, G.A.; Peterson, R.R.; Golovkin, I.E.; Thompson, M.O.; Knowles, T.R.; Raffray, A.R.; Tillack, M.S

    2003-04-01

    We have begun a collaborative investigation of the response of candidate first-wall inertial fusion energy (IFE) reactor chamber drywall materials to X-rays on the Z facility, and to ions on RHEPP-1, both located at Sandia National Laboratories. Dose levels are comparable to those anticipated in future direct-drive reactors. Due to the 5-10 Hz repetition rate expected in such reactors, per-pulse effects such as material removal must be negligible. The primary wall materials investigated here are graphite and tungsten in various forms. After exposure on either RHEPP or Z, materials were analyzed for roughening and/or material removal (ablation) as a function of dose. Graphite is observed to undergo significant ablation/sublimation in response to ion exposure at the 3-4 J/cm{sup 2} level, significantly below doses expected in future dry-wall power plants. Evidence of thermomechanical stresses resulting in material loss occurs for both graphite and tungsten, and is probably related to the pulsed nature of the energy delivery. These effects are not seen in typical magnetic fusion energy (MFE) conditions where these same kinds of materials are used. Results are presented for thresholds below which no roughening or ablation occurs. Use of graphite in a 'velvet' two-dimensional form may mitigate the effects seen with the flat material, and alloying tungsten with rhenium may reduce its roughening due to the increased ductility of the alloy.

  13. Power Capability Investigation Based on Electrothermal Models of Press-pack IGBT Three-Level NPC and ANPC VSCs for Multimegawatt Wind Turbines

    DEFF Research Database (Denmark)

    Senturk, Osman Selcuk; Helle, Lars; Munk-Nielsen, Stig

    2012-01-01

    to provide reactive power support as an ancillary service. For multimegawatt full-scale wind turbines, power capability depends on converter topology and semiconductor switch technology. As power capability limiting factors, switch current, semiconductor junction temperature, and converter output voltage...... are addressed in this study for the three-level neutral-point-clamped voltage source converter (3L-NPC-VSC) and 3L Active NPC VSC (3L-ANPC-VSC) with press-pack insulated gate bipolar transistors employed as a grid-side converter. In order to investigate these VSCs' power capabilities under various operating...... conditions with respect to these limiting factors, a power capability generation algorithm based on the converter electrothermal model is developed. Built considering the VSCs' operation principles and physical structure, the model is validated by a 2 MV·A single-phase 3L-ANPC-VSC test setup. The power...

  14. Experimentation of RT-LOTOS for a critical function of a power plant instrumentation and control system

    International Nuclear Information System (INIS)

    Andriantsiiferana, L.; Courtiat, J.P.; De Oliveira, R.C.

    1996-01-01

    This document is the final report of the contract between LAAS-CNRS and the EdF Direction of Researches and Studies about the experimentation of RT-LOTOS formal description technique on a critical function of a nuclear power plant instrumentation and control system. This report comprises 4 parts: part 1 describes the RT-LOTOS (Real Time-Language of Temporal Ordering Specifications) tutorial and its RTL tool environment, the different RT-LOTOS operators and semantics, and the RTL tool main functionalities; part 2 deals with the methodology and the global architecture for the specification and validation of the CCT (Central Calculator for Treatment); part 3 gives more details about the different processes identified in the specification architecture and presents the main results obtained for the validation of the nominal functioning; part 4 describes some exceptional situations and shows how some failures and their associated recovery mechanisms can be modelled. (J.S.). 6 refs., 53 figs., 5 tabs., 2 appends

  15. Post-reconstruction full power and shut down level 2 PSA study for Unit 1 of Bohunice V1 NPP

    International Nuclear Information System (INIS)

    Kovacs, Z.

    2003-01-01

    The level 2 PSA model of the J. Bohunice V1 NPP was developed in the RISK SPECTRUM Professional code with the following objectives: to identify the ways in which radioactive releases from the plant can occur following the core damage; to calculate the magnitudes and frequency of the release; to provide insights into the plant behaviour during a severe accident; to provide a framework for understanding containment failure modes; the impact of the phenomena that could occur during and following core damage and have the potential to challenge the integrity of the confinement; to support the severe accident management and development of SAMGs. The magnitudes of release categories are calculated using: the MAAP4/VVER for reactor operation and shutdown mode with closed reactor vessel and the MELCOR code for shutdown mode with open reactor vessel. In this paper an overview of the Level 2 PSA methodology; description of the confinement; the interface between the level 1 and 2 PSA and accident progression analyses are presented. An evaluation of the confinement failure modes and construction of the confinement event trees as well as definition of release categories, source term analysis and sensitivity analyses are also discussed. The presented results indicate that: 1)for the full power operation - there is an 25% probability that the confinement will successfully maintain its integrity and prevent an uncontrolled fission product release; the most likely mode of release from the confinement is a confinement bypass after SGTM with conditional probability of 30%; the conditional probability for the confinement isolation failure probability without spray is 5%, for early confinement failure at the vessel failure is 4%, for other categories 1% or less; 2) for the shutdown operating modes - the shutdown risk is high for the open reactor vessel and open confinement; important severe accident sequences exists for release categories: RC5.1, RC5.2 and RC6.2

  16. Modernization of the feedwater heaters control level of the Almaraz I Nuclear Power Plant by OVATION system

    International Nuclear Information System (INIS)

    Madronal Rodriguez, E.; Cabrero Munoz, J. E.

    2010-01-01

    As a result of the process of technological renovation of the heaters system and the power increase project, Almaraz Nuclear Power Plant has made several design changes in the feedwater heaters system. Within these changes, the old heaters control loops are replaced because the new power will increase the heaters drainage caudal. This modernization is carried out using the OVATION control system.

  17. THE RELATIONSHIP BETWEEN AEROBIC POWER AND REPEATED SPRINT ABILITY IN YOUNG SOCCER PLAYERS WITH DIFFERENT LEVELS OF VO2 MAX

    Directory of Open Access Journals (Sweden)

    Rostam Alizadeh

    2010-06-01

    Full Text Available In some team sports such as soccer which is interval, athletes need to prepare themselves immediatelyfor the next activity. Therefore it is very important to have enough information on characteristics of recovery phase and quick recovery to the first situation and to have the minimum speed reduction. The purpose of this study was to determine the relationship between aerobic power and repeated sprint ability (RSA or decrementindex in young soccer players in three different levels of Vo2max. Methods: For this reason 41 volunteers were divided in to three groups with different levels of Vo2max ml.kg-1.min-1 low 37.22 ± 2.3 (n= 18, age 17.1 ± 0.9 year, height 170.6 ± 0.76 cm, weight 67.1 ± 5.05 kg medium 46.46± 1.97 ml.kg-1.min-1 (n= 13, age 17.6± 0.76year, height 173.8 ± 4.84 cm, weight 65.9 ± 4.92 kg and high 55.63 ± 1.52 ml.kg-1.min-1 (n=10, age 17.4 ±0.69 year, height 177 ± 3.23 cm, weight 71.4 ± 3.94 kg. To determine Vo2max a graded exercise test until volitional exhaustion on treadmill was used, and also RAST was used to measure RSA. The lactate accumulation was measured before and after RSA protocol. Pearson's correlation was used to determine the correlation between the aerobic power and RSA. The results indicated that there are significant relationship between Vo2max anddecremental index in low Vo2max group (r= 0.86, p= 0.001, no significant relationship medium Vo2max group (r= 0.14, p= 0.63 and negative significant relationship in high Vo2max group (r= - 0.64, p= 0.04. There are no significant relationship between Lactate accumulation and decremental index in medium (r= 0.005, p= 0.98 and high Vo2max groups (r=0.27, p= 0.45. Discussion: It is possible that the recovery of inter muscular resources relates to aerobic ability, but there are other factors effective in RSA rather than Vo2max and Lactate accumulation. The current study showed a normal curved relationship between Vo2max and RSA.

  18. 14C emission from Swedish nuclear power plants and its effect on the 14C levels in the environment

    International Nuclear Information System (INIS)

    Stenstroem, K.; Erlandsson, Bengt; Hellborg, R.; Kiisk, M.; Persson, Per; Mattsson, Soeren; Thornberg, C.; Skog, G.

    2000-02-01

    The radionuclide 14 C is produced in all types of nuclear reactors mainly by neutron induced reactions in oxygen ( 17 O), nitrogen ( 14 N) and carbon ( 13 C). Part of the 14 C created is continuously released during normal operation as airborne effluents in various chemical forms (such as CO 2 , CO and hydrocarbons) to the surroundings. Because of the biological importance of carbon and the long physical half-life of 14 C, it is of interest to measure the releases and their incorporation into living material. The 14 C activity concentrations in annual tree rings and air around two Swedish nuclear power plants (Barsebaeck and Forsmark) as well as the background 14 C activity levels from two reference sites in southern Sweden during 1973-1996 are presented in this report. In order to verify the reliability of the method some investigations have been conducted at two foreign nuclear sites, Sellafield fuel reprocessing plant in England, and Pickering nuclear generating station in Canada, where the releases of 14 C are known to be substantial. Furthermore, results from some measurements in the vicinity of Paldiski submarine training centre in Estonia are presented. The results of the 14 C measurements of air, vegetation and annual tree rings around the two Swedish nuclear power plants show very low enhancements of 14 C, if at all above the uncertainty of the measurements. Even if the accuracy of the measurements of the annual tree rings is rather good (1-2%) the contribution of 14 C from the reactors to the environment is so small that it is difficult to separate it from the prevailing background levels of 14 C . This is the case for all sampling procedures: in air and vegetation as well as in annual tree rings. Only on a few occasions an actual increase is observed. However, although the calculations suffer from rather large uncertainties, the calculated release rate from Barsebaeck is in fair agreement with reported release data. The results of this investigation show

  19. Procedures for conducting probabilistic safety assessments of nuclear power plants (level 2). Accident progression, containment analysis and estimation of accident source terms

    International Nuclear Information System (INIS)

    1995-01-01

    The present publication on Level 2 PSA is based on a compilation and review of practices in various Member States. It complements Safety Series No. 50-P-4, issued in 1992, on Procedures for Conducting Probabilistic Safety Assessments of Nuclear Power Plants (Level 1). Refs, figs and tabs

  20. High-Level Synthesis: Productivity, Performance, and Software Constraints

    Directory of Open Access Journals (Sweden)

    Yun Liang

    2012-01-01

    Full Text Available FPGAs are an attractive platform for applications with high computation demand and low energy consumption requirements. However, design effort for FPGA implementations remains high—often an order of magnitude larger than design effort using high-level languages. Instead of this time-consuming process, high-level synthesis (HLS tools generate hardware implementations from algorithm descriptions in languages such as C/C++ and SystemC. Such tools reduce design effort: high-level descriptions are more compact and less error prone. HLS tools promise hardware development abstracted from software designer knowledge of the implementation platform. In this paper, we present an unbiased study of the performance, usability and productivity of HLS using AutoPilot (a state-of-the-art HLS tool. In particular, we first evaluate AutoPilot using the popular embedded benchmark kernels. Then, to evaluate the suitability of HLS on real-world applications, we perform a case study of stereo matching, an active area of computer vision research that uses techniques also common for image denoising, image retrieval, feature matching, and face recognition. Based on our study, we provide insights on current limitations of mapping general-purpose software to hardware using HLS and some future directions for HLS tool development. We also offer several guidelines for hardware-friendly software design. For popular embedded benchmark kernels, the designs produced by HLS achieve 4X to 126X speedup over the software version. The stereo matching algorithms achieve between 3.5X and 67.9X speedup over software (but still less than manual RTL design with a fivefold reduction in design effort versus manual RTL design.

  1. Impact of size and distribution of installed PV power in E-W direction on the level in which selected consumers’ energy needs were met

    Directory of Open Access Journals (Sweden)

    Necka Krzysztof

    2018-01-01

    Full Text Available The aim of the study was to analyse the energy needs of selected consumers and to select the PV installed capacity in the east and west panels orientation (E-W. The analysis was carried out for two variants. The first concerned the impact of the installation power of a PV source on the contracted power in its symmetric east and west position. The second variant was the result of previous observations and studies of the authors of this paper. Thus, in this variant, the unbalanced power of PV E-W in relation to the S azimuth has been analyzed, taking into account the characteristics of the recipients' needs and the variation of the PV power installed. The analyses show that an increase in meeting the energy demand for two of the tested plants at symmetrical power distribution to the east and west occurred only when the installed power was increased to the level of approx. 1.4-1.6 of the contracted power. However, the power distribution in the E-W direction has a very strong effect on the energy amount that is generated in the power plant and cannot be used due to the lack of demand in the plant.

  2. Power and area efficient 4-bit column-level ADC in a CMOS pixel sensor for the ILD vertex detector

    International Nuclear Information System (INIS)

    Zhang, L; Morel, F; Hu-Guo, Ch; Hu, Y

    2013-01-01

    A 48 × 64 pixels prototype CMOS pixel sensor (CPS) integrated with 4-bit column-level, self triggered ADCs for the outer layers of the ILD vertex detector (VTX) was developed and fabricated in a 0.35 μm CMOS process with a pixel pitch of 35 μm. The pixel concept combines in-pixel amplification with a correlated double sampling (CDS) operation. The ADCs accommodating the pixel read out in a rolling shutter mode complete the conversion by performing a multi-bit/step approximation. The design was optimised for power saving at sampling frequency. The prototype sensor is currently at the stage of being started testing and evaluation. So what is described is based on post simulation results rather than test data. This 4-bit ADC dissipates, at a 3-V supply and 6.25-MS/s sampling rate, 486 μW in its inactive mode, which is by far the most frequent. This value rises to 714 μW in case of the active mode. Its footprint amounts to 35 × 545 μm 2 .

  3. Power load leveling and energy saving measures for office buildings. Power load leveling and energy saving technology for the new building of the Kobe branch of the Kansai Electric Power Co., and its effect; Office biru no denryoku fuka heijunka sho energy hosaku. Kobe shiten shinshaoku ni okeru denryoku fuka heijunka sho energy gijutsu to sono koka

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiyama, M. [Kansai Electric Power Co. Inc., Osaka (Japan)

    1999-06-10

    This paper presents power load leveling and energy saving measures for heat source, air conditioning and lighting of the new Kobe branch building. The low-temperature hot-air system adopts an ice storage system, and reduces blowing power by 12 degreesC blowing in place of normal 16 degreesC blowing, and an initial cost by duct size reduction. The continuous air conditioning system levels an initial peak load of air conditioning as compared with normal air conditioning only for working hours for buildings with large heat capacity. In addition, as power load leveling measures for the whole building, the complete heat storage system using an underground internal melting type ice storage tank is adopted. Energy saving for lighting is achieved with a dimming lighting controlling its lighting output by inverter. The following effects are expected by these new technologies: Load leveling effect of 30%, energy saving effect of 20.2% and CO{sub 2} reduction effect of 24.1%. (NEDO)

  4. LEVELS OF EXTREMELY LOW-FREQUENCY ELECTRIC AND MAGNETIC FIELDS FROM OVERHEAD POWER LINES IN THE OUTDOOR ENVIRONMENT OF RAMALLAH CITY-PALESTINE.

    Science.gov (United States)

    Abuasbi, Falastine; Lahham, Adnan; Abdel-Raziq, Issam Rashid

    2018-05-01

    In this study, levels of extremely low-frequency electric and magnetic fields originated from overhead power lines were investigated in the outdoor environment in Ramallah city, Palestine. Spot measurements were applied to record fields intensities over 6-min period. The Spectrum Analyzer NF-5035 was used to perform measurements at 1 m above ground level and directly underneath 40 randomly selected power lines distributed fairly within the city. Levels of electric fields varied depending on the line's category (power line, transformer or distributor), a minimum mean electric field of 3.9 V/m was found under a distributor line, and a maximum of 769.4 V/m under a high-voltage power line (66 kV). However, results of electric fields showed a log-normal distribution with the geometric mean and the geometric standard deviation of 35.9 and 2.8 V/m, respectively. Magnetic fields measured at power lines, on contrast, were not log-normally distributed; the minimum and maximum mean magnetic fields under power lines were 0.89 and 3.5 μT, respectively. As a result, none of the measured fields exceeded the ICNIRP's guidelines recommended for general public exposures to extremely low-frequency fields.

  5. Power-level regulation and simulation of nonlinear pressurized water reactor core with xenon oscillation using H-infinity loop shaping control

    Directory of Open Access Journals (Sweden)

    Li Gang

    2016-01-01

    Full Text Available This investigation is to solve the power-level control issue of a nonlinear pressurized water reactor core with xenon oscillations. A nonlinear pressurized water reactor core is modeled using the lumped parameter method, and a linear model of the core is then obtained through the small perturbation linearization way. The H∞loop shapingcontrolis utilized to design a robust controller of the linearized core model.The calculated H∞loop shaping controller is applied to the nonlinear core model. The nonlinear core model and the H∞ loop shaping controller build the nonlinear core power-level H∞loop shaping control system.Finally, the nonlinear core power-level H∞loop shaping control system is simulatedconsidering two typical load processes that are a step load maneuver and a ramp load maneuver, and simulation results show that the nonlinear control system is effective.

  6. Near-Field Acoustic Power Level Analysis of F31/A31 Open Rotor Model at Simulated Cruise Conditions, Technical Report II

    Science.gov (United States)

    Sree, Dave

    2015-01-01

    Near-field acoustic power level analysis of F31A31 open rotor model has been performed to determine its noise characteristics at simulated cruise flight conditions. The non-proprietary parts of the test data obtained from experiments in the 8x6 supersonic wind tunnel were provided by NASA-Glenn Research Center. The tone and broadband components of total noise have been separated from raw test data by using a new data analysis tool. Results in terms of sound pressure levels, acoustic power levels, and their variations with rotor speed, freestream Mach number, and input shaft power, with different blade-pitch setting angles at simulated cruise flight conditions, are presented and discussed. Empirical equations relating models acoustic power level and input shaft power have been developed. The near-field acoustic efficiency of the model at simulated cruise conditions is also determined. It is hoped that the results presented in this work will serve as a database for comparison and improvement of other open rotor blade designs and also for validating open rotor noise prediction codes.

  7. Benefits of spatiotemporal modeling for short-term wind power forecasting at both individual and aggregated levels

    DEFF Research Database (Denmark)

    Lenzi, Amanda; Steinsland, Ingelin; Pinson, Pierre

    2018-01-01

    The share of wind energy in total installed power capacity has grown rapidly in recent years. Producing accurate and reliable forecasts of wind power production, together with a quantification of the uncertainty, is essential to optimally integrate wind energy into power systems. We build...... spatiotemporal models for wind power generation and obtain full probabilistic forecasts from 15 min to 5 h ahead. Detailed analyses of forecast performances on individual wind farms and aggregated wind power are provided. The predictions from our models are evaluated on a data set from wind farms in western...... Denmark using a sliding window approach, for which estimation is performed using only the last available measurements. The case study shows that it is important to have a spatiotemporal model instead of a temporal one to achieve calibrated aggregated forecasts. Furthermore, spatiotemporal models have...

  8. The intermediates take it all: asymptotics of higher criticism statistics and a powerful alternative based on equal local levels.

    Science.gov (United States)

    Gontscharuk, Veronika; Landwehr, Sandra; Finner, Helmut

    2015-01-01

    The higher criticism (HC) statistic, which can be seen as a normalized version of the famous Kolmogorov-Smirnov statistic, has a long history, dating back to the mid seventies. Originally, HC statistics were used in connection with goodness of fit (GOF) tests but they recently gained some attention in the context of testing the global null hypothesis in high dimensional data. The continuing interest for HC seems to be inspired by a series of nice asymptotic properties related to this statistic. For example, unlike Kolmogorov-Smirnov tests, GOF tests based on the HC statistic are known to be asymptotically sensitive in the moderate tails, hence it is favorably applied for detecting the presence of signals in sparse mixture models. However, some questions around the asymptotic behavior of the HC statistic are still open. We focus on two of them, namely, why a specific intermediate range is crucial for GOF tests based on the HC statistic and why the convergence of the HC distribution to the limiting one is extremely slow. Moreover, the inconsistency in the asymptotic and finite behavior of the HC statistic prompts us to provide a new HC test that has better finite properties than the original HC test while showing the same asymptotics. This test is motivated by the asymptotic behavior of the so-called local levels related to the original HC test. By means of numerical calculations and simulations we show that the new HC test is typically more powerful than the original HC test in normal mixture models. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. A study on water level control of PWR steam generator at low power and the self-tuning of its fuzzy controller

    International Nuclear Information System (INIS)

    Na, N.; Kwon, K.; Ham, C.; Bien, Z.

    1994-01-01

    The water level control system of a steam generator in a pressurized water reactor and its control problems during the operation at low power is analysed. In particular, a strategy for a water level control system, which is based on the use of a fuzzy logic controller, is proposed. The control strategy includes dynamic tuning for the large transient. The fuzzy variable of the flow rate during the power operation is obtained from the bypass valve opening and not from the incorrect measured signal at the low flow rate. The practical self-tuning algorithm is based on the optimal control performance

  10. Admissibility of building cost subsidy in the power grid above the low voltage level; Zulaessigkeit von Baukostenzuschuessen im Stromnetz oberhalb der Niederspannungsebene

    Energy Technology Data Exchange (ETDEWEB)

    Foerster, Sven [Kanzlei Norton Rose Fulbright LLP, Muenchen(Germany)

    2015-07-01

    Electricity networks are essential to the provision of electrical power to businesses and individuals. In particular for manufacturing businesses a connection to the grid above the low-voltage level is often useful. Network operators demand a subsidy for the new connection and for the change to a higher network level under the auspices of construction cost. The power network market above the low-voltage level is a natural monopoly. This leaves consumers looking for a connection to the power grid with no possibility to select among different network operators. Construction cost subsidies are not regulated by law above the low voltage level. The lack of legal regulation and the natural monopoly above the low-voltage level affect the balance of power between network operators and system users. The lawfulness of the construction cost subsidies, the prerequisites for their demand and a review of the calculation models (Leistungspreismodell, 2-Ebenen-Modell) as well as a proposal for a reform of this system form the subject of this work.

  11. Effect of variable power levels on the yield of total aerosol mass and formation of aldehydes in e-cigarette aerosols.

    Science.gov (United States)

    Gillman, I G; Kistler, K A; Stewart, E W; Paolantonio, A R

    2016-03-01

    The study objective was to determine the effect of variable power applied to the atomizer of refillable tank based e-cigarette (EC) devices. Five different devices were evaluated, each at four power levels. Aerosol yield results are reported for each set of 25 EC puffs, as mass/puff, and normalized for the power applied to the coil, in mass/watt. The range of aerosol produced on a per puff basis ranged from 1.5 to 28 mg, and, normalized for power applied to the coil, ranged from 0.27 to 1.1 mg/watt. Aerosol samples were also analyzed for the production of formaldehyde, acetaldehyde, and acrolein, as DNPH derivatives, at each power level. When reported on mass basis, three of the devices showed an increase in total aldehyde yield with increasing power applied to the coil, while two of the devices showed the opposite trend. The mass of formaldehyde, acetaldehyde, and acrolein produced per gram of total aerosol produced ranged from 0.01 to 7.3 mg/g, 0.006 to 5.8 mg/g, and acrolein from EC aerosols from specific devices, and were compared to estimated exposure from consumption of cigarettes, to occupational and workplace limits, and to previously reported results from other researchers. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  12. Effect of a time varying power level in EBR-II on mixed-oxide fuel burnup

    International Nuclear Information System (INIS)

    Stone, I.Z.; Jost, J.W.; Baker, R.B.

    1979-01-01

    A refined prediction of burnup of mixed-oxide fuel in EBR-2 is compared with measured data. The calculation utilizes a time-varying power factor and results in a general improvement to previous calculations

  13. Load leveling by a battery system in an electric power system with a photovoltaic system; Taiyoko hatsuden system ga donyusareta denryoku keito no chikudenchi ni yoru fuka heijunka

    Energy Technology Data Exchange (ETDEWEB)

    Kenmoku, Y.; Sakakibara, T. [Toyohashi University of Technology, Aichi (Japan); Nakagawa, S. [Maizuru College of Technology, Kyoto (Japan); Kawamoto, T. [Shizuoka University, Shizuoka (Japan)

    1997-11-25

    Storage battery-aided load leveling system is introduced into a power system having a photovoltaic power generation (PV) system, and the effect of the introduction is examined. For this purpose, the resultant improvement on the load factor and reduction in the annual cost are evaluated. Used as the load factor in the studies are the hourly records of power transmitted and received by Chubu Electric Power Co., Inc., in 1995. The output of the PV system is calculated using weather data collected in Nagoya City in the same year. Findings as the result of the studies are stated below. The maximum power is suppressed but a little if it is only the PV system that is introduced into the system. That is, a 2GW PV system introduced into the system suppresses the maximum power only by 0.5GW or less. The maximum power is suppressed more effectively when a storage battery is added, and it decreases linearly with an increase in the storage battery capacity. As for reduction in the cost, the reducing effect is higher when the rate of storage battery capacity/introduced PV capacity is higher in the presence of an introduced PV capacity of 0.8GW or more. 2 refs., 7 figs., 3 tabs.

  14. The Influence of RSG-GAS Primary Pump Operation Concerning the Rise Water Level of Reactor Pool in 15 MW Reactor Power

    International Nuclear Information System (INIS)

    Djunaidi

    2004-01-01

    The expansion of air volume in the delay chamber shows in rise water level of reactor pool during the operation. The rises of water level in the reactor pool is not quite from the expansion of air volume in the delay chamber, but some influence the primary pump operation. The purpose evaluated of influence primary pump is to know the influence primary pump power concerning the rise water level during the reactor operation. From the data collection during 15 MW power operation in the last core 42 the influence of primary pump operation concerning the rise water level in the reactor pool is 34.48 % from the total increased after operation during 12 days. (author)

  15. Simulation and Modeling of a Five -Level (NPC Inverter Fed by a Photovoltaic Generator and Integrated in a Hybrid Wind-PV Power System

    Directory of Open Access Journals (Sweden)

    M. Rezki,

    2017-08-01

    Full Text Available A distributed hybrid coordinated wind photovoltaic (PV power system was proposed in this paper. As oil and coal reserves are being depleted whilst at the same time the energy demand is growing, it is important to consider alternative energy generating techniques. Today, the five-level (NPC inverter represents a good alternative for several industrial applications. To take advantage of the five-level inverter topology and the benefits of renewable energy represented by a photovoltaic generator, a new scheme of these controllers is proposed in this work. This paper outlines the design of a hybrid power system consisting of a solar photovoltaic (PV and a wind power system. The system is modeled in Matlab Simulink and tested for various conditions. The model and results are discussed in this paper.

  16. An radiotoxicity evaluation of high level wastes for a scenery of Brazilian Nuclear Power Plants in accordance with the Energy Expansion Brazilian Plan 2030

    International Nuclear Information System (INIS)

    Guilhem, Andres C.; Maiorino, Jose R.

    2011-01-01

    This paper is a part of the author scientific initiation, and makes an evaluation of the radiotoxicity which would be produced by the Brazilian nuclear power plants in a scenery of 7 power plants operating in 2030, in according to the official expansion plans which point out the additional introduction of 4000 MW(e), or 4 ne power plant additionally to the Angra I, II and III. Considering that all reactors would be a PWR reactors. The calculated parameter was the relative toxicity of the low and intermediate level nuclear wastes (LLPP - long lived fission products and HLW - high level waste related to the radiotoxicity of natural uranium versus time. All the calculation used the ORIGEN-S code. (author)

  17. 14C levels in the vicinity of the Fukushima Dai-ichi Nuclear Power Plant prior to the 2011 accident

    International Nuclear Information System (INIS)

    Xu, Sheng; Cook, Gordon T.; Cresswell, Alan J.; Dunbar, Elaine; Freeman, Stewart P.H.T.; Hastie, Helen; Hou, Xiaolin; Jacobsson, Piotr; Naysmith, Philip; Sanderson, David C.W.; Tripney, Brian G.; Yamaguchi, Katsuhiko

    2016-01-01

    A 50-year-old Japanese cedar (Cryptomeria japonica) from Okuma, ∼1 km southwest of the Fukushima Dai-ichi Nuclear Power Plant, was cored and each annual ring was analysed for 14 C. The 14 C specific activity values varied from 330.4 Bq kg −1  C in the tree ring formed in 1971 to 231.2 Bq kg −1  C in the 2014 ring. During the periods 1971–1976 and 2011–2014, the 14 C specific activities are indistinguishable from the ambient background values. However, compared with the ambient atmospheric levels, the 14 C specific activities between 1977 and 2010 are significantly elevated, clearly indicating 14 C discharges from the reactors during their normal operations. In addition, the specific activities are positively correlated with the annual electricity generation values. The excess 14 C specific activities were <36 Bq kg −1  C, corresponding to an additional annual effective dose of <2 μSv via the food ingestion pathway in the study location. The primary wind direction is east-southeast/southeast with a frequency of ∼30%, in comparison to ∼20% frequency for the direction of the site under study (north-northeast/northeast). This would tend to indicate a similar magnitude of additional effective dose and consequently no significant radiological impact of atmospheric 14 C discharges from the FDNPP during the entire period of normal operations. Additionally, no 14 C pulse in activity can be observed in the year 2011 ring. This might be caused by a limited 14 C release from the damaged reactors during the accident or that the prevailing wind during the short period of release (11th–25th March 2011) was not in the direction of Okuma. - Highlights: • The 14 C variation in 1971–1976 and 2011–2014 is ascribed as an exponential decline. • The 14 C discharge from FDNPP normal operation caused 14 C enrichment in 1977–2010. • Total 53 TBq 14 C were released during the whole period of the normal operations. • No visible accident 14 C pulse

  18. Determination of Environmental Radiation and Radioactivity Levels at a Coal Fired Power Plant Site in Paiton Region

    International Nuclear Information System (INIS)

    Sutarman; Nareh, Marzaini; Warsona, Asep; Emlinarni; Buchari, R.

    2003-01-01

    Determination of environmental radiation and radioactivity levels at a coal fired power plant (CFPP) site in Paiton region, Probolinggo (East Java) has been carried out. The objective of this study is to calculate the distribution of natural radionuclide concentrations in the various environmental. The study area covered the area in radius of 10 km from a stack of CFPP. Measurement of concentration 2 28Th, 2 26Ra, and 4 0K in the various environmental samples were carried out using the gamma spectrometer with a detector of semiconductor HP-Ge. Measurement of concentration 1 4C and gross alpha in air has been carried out using the liquid scintillation counting and low background counting α/β system respectively. Measurement of gamma radiation has been carried out directly using the ionization chamber. The result of measurement show that highest concentration in soil was (80.81±0.39) Bq/kg for 2 28Th, (74.43±0.65) Bq/kg for 2 26Ra, and (520.43±5.36) Bq/kg for 4 0K. the highest concentration in water was (37.20±0.75) mBq/L for 2 28Th, undetectable for 2 26Ra, and (90.82±1.74) mBq/L for 4 0K. the highest concentration in grass/agriculture product was (0.98±0.05) Bq/kg wet for 2 28Th, (0.75±0.05) Bq/kg wet for 2 26Ra, and (34.53±0.01) Bq/kg wet for 4 0K. the highest concentration 1 4C and gross alpha in air was (11.9±1.9)x10 -3 Bq/m 3 and (3.59±1.89) Bq/m 3 , and the highest dose rate was (9.55±0.13) μR/h. The measurement values obtained are all below the maximum permissible concentration and dose limits in environment

  19. Web-Based Learning Enhancements: Video Lectures through Voice-Over PowerPoint in a Majors-Level Biology Course

    Science.gov (United States)

    Lents, Nathan H.; Cifuentes, Oscar E.

    2009-01-01

    This study is an experimental introduction of web-based lecture delivery into a majors-level introductory biology course. Web-based delivery, achieved through the use of prerecorded Voice-Over PowerPoint video lectures, was introduced on a limited basis to an experimental section while a control group, with the same instructor, received standard…

  20. Validation of the Predicted Circumferential and Radial Mode Sound Power Levels in the Inlet and Exhaust Ducts of a Fan Ingesting Distorted Inflow

    Science.gov (United States)

    Koch, L. Danielle

    2012-01-01

    Fan inflow distortion tone noise has been studied computationally and experimentally. Data from two experiments in the NASA Glenn Advanced Noise Control Fan rig have been used to validate acoustic predictions. The inflow to the fan was distorted by cylindrical rods inserted radially into the inlet duct one rotor chord length upstream of the fan. The rods were arranged in both symmetric and asymmetric circumferential patterns. In-duct and farfield sound pressure level measurements were recorded. It was discovered that for positive circumferential modes, measured circumferential mode sound power levels in the exhaust duct were greater than those in the inlet duct and for negative circumferential modes, measured total circumferential mode sound power levels in the exhaust were less than those in the inlet. Predicted trends in overall sound power level were proven to be useful in identifying circumferentially asymmetric distortion patterns that reduce overall inlet distortion tone noise, as compared to symmetric arrangements of rods. Detailed comparisons between the measured and predicted radial mode sound power in the inlet and exhaust duct indicate limitations of the theory.

  1. Technique for estimating the sound power level radiated by pneumatic rock drills and the evaluation of a CSIR prototype rock drill with engineering noise controls

    CSIR Research Space (South Africa)

    Kovalchik, PG

    2009-05-01

    Full Text Available and the radiation patterns in octave and 1/3 octave bands. Overall sound power level is also determined. This paper also reports the results obtained by using this procedure to evaluate a SECO S215 standard production drill and a CSIR Miningtek prototype rock drill...

  2. Converter Structure-Based Power Loss and Static Thermal Modeling of The Press-Pack IGBT Three-Level ANPC VSC Applied to Multi-MW Wind Turbines

    DEFF Research Database (Denmark)

    Senturk, Osman Selcuk; Helle, Lars; Munk-Nielsen, Stig

    2011-01-01

    performance, the converter structure-based power loss and thermal models are developed in this study for the medium-voltage (MV) three-level active neutral-point-clamped voltage source converter (3L-ANPC-VSC) utilizing 4500 V-1800 A press-pack insulated-gate bipolar transistor-diode pairs and interfacing a 6...

  3. Harmonization of nuclear and radiation safety regulations for nuclear power plants with reference levels of Western European Nuclear Regulators Association (WENRA)

    International Nuclear Information System (INIS)

    Bojchuk, V.S.; Mikolajchuk, O.A.; Gromov, G.V.; Dibach, O.M.; Godovanyuk, G.M.; Nosovs'kij, A.V.

    2014-01-01

    Self-evaluation of the Ukrainian regulations on nuclear and radiation safety that apply to nuclear power plants for compliance with the reference levels of the Western European Nuclear Regulators Association (WENRA) is presented. Proposals on improvement of the regulations upon self-evaluation are provided

  4. The impact of power market reforms on electricity price-cost margins and cross-subsidy levels: A cross country panel data analysis

    International Nuclear Information System (INIS)

    Erdogdu, Erkan

    2011-01-01

    One of the main expectations from power market reform has been a reduction in both price-cost margins and cross-subsidy levels between industrial and residential consumers. This paper focuses on this issue by looking at the impact of the electricity industry reforms on residential and industrial electricity price-cost margins and their effect on cross-subsidy levels between consumer groups. Using panel data for 63 developed and developing countries covering the period 1982-2009, empirical models are developed and analyzed. The research findings suggest that there is no uniform pattern for the impact of reform process as a whole on price-cost margins and cross-subsidy levels. Each individual reform step has different impact on price-cost margins and cross-subsidy levels for each consumer and country group. Our findings imply that reform steps have different impacts in different countries, which supports the idea reform prescription for a specific country cannot easily and successfully be transferred to another one. So, transferring the formal and economic structure of a successful power market in a developed country to developing countries is not a sufficient condition for good economic performance of the electricity industries in developing countries. Furthermore, the study suggests that power consumption, income level and country-specific features constitute other important determinants of electricity price-cost margins and cross-subsidy levels. - Research highlights: → The paper focuses on the impact of power market reforms on price-cost margins and cross-subsidy levels. → Using panel data for 63 countries for the period 1982-2009, empirical models are developed and analyzed. → We found that each individual reform step has different impact for each consumer and country group. → We conclude that reform prescription for a specific country cannot easily be transferred to another one.

  5. A Study on the Risk Reduction Effect by MLCS (Mid-loop Level Control System) of EUAPR using the Low-Power and Shutdown PSA Result

    International Nuclear Information System (INIS)

    Lee, Keunsung; Choi, Sunmi; Kim, Eden

    2016-01-01

    The EU-APR design has been developed in order to expand and diversify the global nuclear power market of APR1400. For the improvement of shutdown risk for the EUAPR, the mid-loop level control system (MLCS) is considered during mid-loop operation for the EU-APR, which is not incorporated into SKN 3 and 4 (APR1400 Type) in Korea. Commonly, the risk associated with the NPP can be identified through the PSA. Thus, this paper discusses the low power and shutdown (LPSD) risk reduction effect by MLCS using the Low-Power and Shutdown PSA Result. LPSD level 1 PSA models for EU-APR have been developed. The risk reduction effect by MLCS is discussed. Because the loss of shutdown cooling function during mid-loop is one of the most vulnerable events, the MLCS have a significant influence on CDF in LPSD PSA. The shutdown risk of domestic power plants would likely be reduced if the MLCS is adopted in all operating NPPs in Korea during the mid-loop operation. It is expected that this work will contribute to reduce shutdown risk of domestic power plants

  6. An Active Power Filter Based on a Three-Level Inverter and 3D-SVPWM for Selective Harmonic and Reactive Compensation

    Directory of Open Access Journals (Sweden)

    José Luis Monroy-Morales

    2017-03-01

    Full Text Available Active Power Filters (APFs have been used for reducing waveform distortion and improving power quality. However, this function can be improved by means of a selective harmonic compensation. Since an APF has rating restrictions, it is convenient to have the option of selecting an individual or a set of particular harmonics in order to compensate and apply the total APF capabilities to eliminate these harmonics, in particular those with a greater impact on the Total Harmonic Distortion (THD. This paper presents the development of a new APF prototype based on a three-phase three-level Neutral Point Clamped (NPC inverter with selective harmonic compensation capabilities and reactive power compensation. The selective harmonic compensation approach uses several Synchronous Rotating Frames (SRF, to detect and control individual or a set of harmonics using d and q variables. The APF includes a Three-Dimensional Space Vector Modulator (3D-SVPWM in order to generate the compensation currents. Because of its multilevel topology, the proposed active power filter can be used in diverse power quality applications at sub-transmission and distribution voltage levels. Simulation and experimental results are shown to validate the proposed solution and assess the prototype performance in different scenarios.

  7. Effects of uneven temperature of IGBT and diode on switching characteristics of bridge legs in MW-level power converters

    DEFF Research Database (Denmark)

    Luo, Haoze; Iannuzzo, Francesco; Blaabjerg, Frede

    2016-01-01

    profile, the junction temperatures of inspected IGBT and related commutation diode are controlled independently using off-line test platform. In consideration of the structural layout, parasitic parameter effects and independent junction temperature control, a high-power switching characteristics platform...... was built. High power compact IGBT modules with 1.7kV rating and 3.6kA current rating are used for the experimental evaluation and platform feasibility. The quantitative analyses of uneven temperature effects on the switching characteristics are investigated and experimentally validated....

  8. Milliwatt-level output power in the sub-terahertz range generated by photomixing in a GaAs photoconductor

    Science.gov (United States)

    Peytavit, E.; Lepilliet, S.; Hindle, F.; Coinon, C.; Akalin, T.; Ducournau, G.; Mouret, G.; Lampin, J.-F.

    2011-11-01

    It is shown from accurate on-wafer measurement that continuous wave output powers of 1.2 mW at 50 GHz and 0.35 mW at 305 GHz can be generated by photomixing in a low temperature grown GaAs photoconductor using a metallic mirror Fabry-Pérot cavity. The output power is improved by a factor of about 100 as compared to the previous works on GaAs photomixers. A satisfactory agreement between the theory and the experiment is obtained in considering both the contribution of the holes and the electrons to the total photocurrent.

  9. Planar wire array dynamics and radiation scaling at multi-MA levels on the Saturn pulsed power generator

    International Nuclear Information System (INIS)

    Chuvatin, Alexander S.; Vesey, Roger Alan; Waisman, Eduardo Mario; Esaulov, Andrey A.; Ampleford, David J.; Kantsyrev, Victor Leonidovich; Cuneo, Michael Edward; Rudakov, Leonid I.; Coverdale, Christine Anne; Jones, Brent Manley; Safronova, Alla S.; Jones, Michael C.

    2008-01-01

    Planar wire arrays are studied at 3-6 MA on the Saturn pulsed power generator as potential drivers of compact hohlraums for inertial confinement fusion studies. Comparison with zero-dimensional modeling suggests that there is significant trailing mass. The modeled energy coupled from the generator cannot generally explain the energy in the main x-ray pulse. Preliminary comparison at 1-6 MA indicates sub-quadratic scaling of x-ray power in a manner similar to compact cylindrical wire arrays. Time-resolved pinhole images are used to study the implosion dynamics

  10. Ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model.

    Science.gov (United States)

    Homayounfar, Kia; Meis, Johanna; Jung, Klaus; Klosterhalfen, Bernd; Sprenger, Thilo; Conradi, Lena-Christin; Langer, Claus; Becker, Heinz

    2012-02-23

    Ultrasonic scalpel (UC) and monopolar electrocautery (ME) are common tools for soft tissue dissection. However, morphological data on the related tissue alteration are discordant. We developed an automatic device for standardized sample excision and compared quality and depth of morphological changes caused by UC and ME in a pig model. 100 tissue samples (5 × 3 cm) of the abdominal wall were excised in 16 pigs. Excisions were randomly performed manually or by using the self-constructed automatic device at standard power levels (60 W cutting in ME, level 5 in UC) for abdominal surgery. Quality of tissue alteration and depth of coagulation necrosis were examined histopathologically. Device (UC vs. ME) and mode (manually vs. automatic) effects were studied by two-way analysis of variance at a significance level of 5%. At the investigated power level settings UC and ME induced qualitatively similar coagulation necroses. Mean depth of necrosis was 450.4 ± 457.8 μm for manual UC and 553.5 ± 326.9 μm for automatic UC versus 149.0 ± 74.3 μm for manual ME and 257.6 ± 119.4 μm for automatic ME. Coagulation necrosis was significantly deeper (p power levels.

  11. A novel optimised and validated method for analysis of multi-residues of pesticides in fruits and vegetables by microwave-assisted extraction (MAE)-dispersive solid-phase extraction (d-SPE)-retention time locked (RTL)-gas chromatography-mass spectrometry with Deconvolution reporting software (DRS).

    Science.gov (United States)

    Satpathy, Gouri; Tyagi, Yogesh Kumar; Gupta, Rajinder Kumar

    2011-08-01

    A rapid, effective and ecofriendly method for sensitive screening and quantification of 72 pesticides residue in fruits and vegetables, by microwave-assisted extraction (MAE) followed by dispersive solid-phase extraction (d-SPE), retention time locked (RTL) capillary gas-chromatographic separation in trace ion mode mass spectrometric determination has been validated as per ISO/IEC: 17025:2005. Identification and reporting with total and extracted ion chromatograms were facilitated to a great extent by Deconvolution reporting software (DRS). For all compounds LOD were 0.002-0.02mg/kg and LOQ were 0.025-0.100mg/kg. Correlation coefficients of the calibration curves in the range of 0.025-0.50mg/kg were >0.993. To validate matrix effects repeatability, reproducibility, recovery and overall uncertainty were calculated for the 35 matrices at 0.025, 0.050 and 0.100mg/kg. Recovery ranged between 72% and 114% with RSD of <20% for repeatability and intermediate precision. The reproducibility of the method was evaluated by an inter laboratory participation and Z score obtained within ±2. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. Power level control of the TRIGA Mark-II research reactor using the multifeedback layer neural network and the particle swarm optimization

    International Nuclear Information System (INIS)

    Coban, Ramazan

    2014-01-01

    Highlights: • A multifeedback-layer neural network controller is presented for a research reactor. • Off-line learning of the MFLNN is accomplished by the PSO algorithm. • The results revealed that the MFLNN–PSO controller has a remarkable performance. - Abstract: In this paper, an artificial neural network controller is presented using the Multifeedback-Layer Neural Network (MFLNN), which is a recently proposed recurrent neural network, for neutronic power level control of a nuclear research reactor. Off-line learning of the MFLNN is accomplished by the Particle Swarm Optimization (PSO) algorithm. The MFLNN-PSO controller design is based on a nonlinear model of the TRIGA Mark-II research reactor. The learning and the test processes are implemented by means of a computer program at different power levels. The simulation results obtained reveal that the MFLNN-PSO controller has a remarkable performance on the neutronic power level control of the reactor for tracking the step reference power trajectories

  13. Replacement of the level control of draining tanks MSRS and powered water heaters with the OVATION system in Asco NPP

    International Nuclear Information System (INIS)

    Serrano Jimenez, J.

    2012-01-01

    The current MSR drains and heaters tanks level control is local control individual, pneumatic and without action from Control room. The system has level switches for the generation of alarms, isolations and shots of bombs. Single control room operators have level alarms, final race of valves of control and indication of temperature and pressure of some tanks.

  14. A novel power control strategy of Modular Multi-level Converter in HVDC-AC hybrid transmission systems for passive networks

    DEFF Research Database (Denmark)

    Hu, Zhenda; Wu, Rui; Yang, Xiaodong

    2014-01-01

    With the development of High Voltage DC Transmission (HVDC) technology, there will be more and more HVDC-AC hybrid transmission system in the world. A basic challenge in HVDC-AC hybrid transmission systems is to optimize the power sharing between DC and AC lines, which become more severe when sup...... control strategy of Modular Multi-level Converter in VSC-HVDC, which can optimize converter output power according to passive network loading variation. Proposal method is studied with a case study of a VSC-HVDC AC hybrid project by PSCAD/EMTDC simulations....

  15. Metabolic cost of level-ground walking with a robotic transtibial prosthesis combining push-off power and nonlinear damping behaviors: preliminary results.

    Science.gov (United States)

    Yanggang Feng; Jinying Zhu; Qining Wang

    2016-08-01

    Recent advances in robotic technology are facilitating the development of robotic prostheses. Our previous studies proposed a lightweight robotic transtibial prosthesis with a damping control strategy. To improve the performance of power assistance, in this paper, we redesign the prosthesis and improve the control strategy by supplying extra push-off power. A male transtibial amputee subject volunteered to participate in the study. Preliminary experimental results show that the proposed prosthesis with push-off control improves energy expenditure by a percentage ranged from 9.72 % to 14.99 % for level-ground walking compared with the one using non-push-off control.

  16. Loss and thermal redistributed modulation methods for three-level neutral-point-clamped wind power inverter undergoing Low Voltage Ride Through

    DEFF Research Database (Denmark)

    Ma, Ke; Blaabjerg, Frede

    2012-01-01

    The three-level neutral-point-clamped (3L-NPC) converter is a promising multilevel topology in the application of mega-watts wind power generation system. However, the growing requirements by grid codes may impose high stress and even give reliability problem to this converter topology. This paper...... modulation methods, the thermal distribution in the 3L-NPC wind power inverter undergoing LVRT becomes more equal, and the junction temperature of the most stressed devices can be also relieved. Also the control ability of DC-bus neutral point potential, which is one of the crucial considerations for the 3L...

  17. Management of very low level waste from decommissioning of the A-1 Jaslovske Bohunice nuclear power plant in Slovakia

    International Nuclear Information System (INIS)

    Burclova, J.; Konecny, L.; Mrskova, A.

    2000-01-01

    Efforts were made to accelerate decommissioning, particularly of the nuclear power plant A1 of the HWGCR type. Progress made and current developments in this subject area are reviewed. Radioactive waste categories are described along with release criteria. An overview is provided on contaminated scrap and the sorting of contaminated soil and concrete. (author)

  18. Levelling the Playing Fields in PAR: The Intricacies of Power, Privilege, and Participation in a University-Community-School Partnership

    Science.gov (United States)

    Wood, Lesley; McAteer, Mary

    2017-01-01

    When academics, who occupy a traditional position of power and privilege, engage with community members whose thinking, attitudes, and responses have been shaped by ongoing sociohistorical oppression and disadvantage, democratic participation is not easy to attain. Yet, unless community members feel able to participate freely, the valuable local…

  19. Influence of the level of fit of a density probability function to wind-speed data on the WECS mean power output estimation

    International Nuclear Information System (INIS)

    Carta, Jose A.; Ramirez, Penelope; Velazquez, Sergio

    2008-01-01

    Static methods which are based on statistical techniques to estimate the mean power output of a WECS (wind energy conversion system) have been widely employed in the scientific literature related to wind energy. In the static method which we use in this paper, for a given wind regime probability distribution function and a known WECS power curve, the mean power output of a WECS is obtained by resolving the integral, usually using numerical evaluation techniques, of the product of these two functions. In this paper an analysis is made of the influence of the level of fit between an empirical probability density function of a sample of wind speeds and the probability density function of the adjusted theoretical model on the relative error ε made in the estimation of the mean annual power output of a WECS. The mean power output calculated through the use of a quasi-dynamic or chronological method, that is to say using time-series of wind speed data and the power versus wind speed characteristic of the wind turbine, serves as the reference. The suitability of the distributions is judged from the adjusted R 2 statistic (R a 2 ). Hourly mean wind speeds recorded at 16 weather stations located in the Canarian Archipelago, an extensive catalogue of wind-speed probability models and two wind turbines of 330 and 800 kW rated power are used in this paper. Among the general conclusions obtained, the following can be pointed out: (a) that the R a 2 statistic might be useful as an initial gross indicator of the relative error made in the mean annual power output estimation of a WECS when a probabilistic method is employed; (b) the relative errors tend to decrease, in accordance with a trend line defined by a second-order polynomial, as R a 2 increases

  20. Influence of the level of fit of a density probability function to wind-speed data on the WECS mean power output estimation

    Energy Technology Data Exchange (ETDEWEB)

    Carta, Jose A. [Department of Mechanical Engineering, University of Las Palmas de Gran Canaria, Campus de Tafira s/n, 35017 Las Palmas de Gran Canaria, Canary Islands (Spain); Ramirez, Penelope; Velazquez, Sergio [Department of Renewable Energies, Technological Institute of the Canary Islands, Pozo Izquierdo Beach s/n, 35119 Santa Lucia, Gran Canaria, Canary Islands (Spain)

    2008-10-15

    Static methods which are based on statistical techniques to estimate the mean power output of a WECS (wind energy conversion system) have been widely employed in the scientific literature related to wind energy. In the static method which we use in this paper, for a given wind regime probability distribution function and a known WECS power curve, the mean power output of a WECS is obtained by resolving the integral, usually using numerical evaluation techniques, of the product of these two functions. In this paper an analysis is made of the influence of the level of fit between an empirical probability density function of a sample of wind speeds and the probability density function of the adjusted theoretical model on the relative error {epsilon} made in the estimation of the mean annual power output of a WECS. The mean power output calculated through the use of a quasi-dynamic or chronological method, that is to say using time-series of wind speed data and the power versus wind speed characteristic of the wind turbine, serves as the reference. The suitability of the distributions is judged from the adjusted R{sup 2} statistic (R{sub a}{sup 2}). Hourly mean wind speeds recorded at 16 weather stations located in the Canarian Archipelago, an extensive catalogue of wind-speed probability models and two wind turbines of 330 and 800 kW rated power are used in this paper. Among the general conclusions obtained, the following can be pointed out: (a) that the R{sub a}{sup 2} statistic might be useful as an initial gross indicator of the relative error made in the mean annual power output estimation of a WECS when a probabilistic method is employed; (b) the relative errors tend to decrease, in accordance with a trend line defined by a second-order polynomial, as R{sub a}{sup 2} increases. (author)

  1. Coal transitions in China's power sector: A plant-level assessment of stranded assets and retirement pathways

    International Nuclear Information System (INIS)

    Spencer, Thomas; Berghmans, Nicolas; Sartor, Oliver

    2017-11-01

    This paper estimates the potential scale of stranded assets in the coal power sector in China under different policy scenarios. A number of factors are putting significant pressure on the coal-power sector: a recent investment bubble in new capacity, structural slowing in electricity demand growth, upcoming moves to liberalize electricity markets and introduce a carbon market, and continued support for renewable and low-carbon sources of electricity. Stranded assets in the Chinese coal-fired power sector are estimated at 90 billion USD 2015 under the current policy trajectory (NDC-Style Scenario). This situation threatens to increase the political economy challenges of China's electricity sector transition to a low-carbon system. This situation is not unique to China: other countries will also face coal-sector stress due to the competitiveness of renewables, and therefore managing existing coal power capacities needs to move to the forefront of climate and energy policy efforts. To turn this situation around, Chinese authorities should have a strategy for a managed phase-down of coal power assets. All new construction of coal power plants should cease: recent project cancellations have been a step in the right direction. A planned retirement schedule for old coal plants that have already made a return on investment should be developed to 2030. Existing, newer coal plants should be prepared to play a role and receive revenues for balancing a high renewables system. A managed 2 deg. C-compatible climate mitigation scenario, in which old plant are retired after 30 years, both puts China's electricity sector on an accelerated pathway to decarbonization, as well as lowering the risks of stranded assets compared to the NDC-Style Scenario, by a total of 12 billion USD 2015. Banking sector exposure to stranded assets in the Managed 2 deg. C Scenario are estimated at less than 10% of the banking sector's loan loss provisions: risks of financial disruption are

  2. Final report on the survey to verify a new method for power load leveling; Fuka heijunka shinshuho jissho chosa saishu hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    The purpose of this verification survey is to verify the effectiveness of a system using capacitor for power load leveling and output leveling in the photovoltaic power generation. For the former, the charge is conducted in the nighttime, and the discharge in load peak time in the daytime. The capacity required is small for the output, and therefore, there is a viability of capacitor. For the latter, abrupt output variations by solar cells are leveled by storage device using capacitor. Since the output variation generated in a short time by solar cells requires responsibility and life in case of abrupt charge/discharge, it is suitable to use capacitor. The demonstration use capacitor is an organic stacking type for the former, and an organic jelly-role type for the latter. As a result of the demonstration, for the former, a power storage system which has 32-module series/parallel connection bank switch type + 2-way ac/dc exchanger was made and operated for verification. The overall efficiency of 85% was obtained. For the latter, a system which has 2,400F x 70 series bank, 6,000F x 70 series bank x 3 parallel bank and 3kW solar cells was operated for verification. Much effect of output leveling was confirmed. (NEDO)

  3. Evaluation of Steam Generator Level behavior for Determination of Turbine Runback rate on COPs trip for Yonggwang 1 and 2 Power Uprating Units

    International Nuclear Information System (INIS)

    Lee, Kyung Jin; Hwang, Su Hyun; Yoo, Tae Geun; Chung, Soon Il; An, Byung Chang; Park, Jung Gu

    2010-01-01

    4.5% power uprate project has been progressing for the first time in Yonggwang 1 and 2(YGN1 and 2). Reviews for design change due to the power uprate were accomplished. Steam generator level behavior was one of the most important parameters because it could be cause of reactor trip or turbine trip. As the results of the reviews, YGN1 and 2 had to reassess it for change of turbine runback rate when turbine runback occurs due to the condensate operating pumps (COP) trip. This study has been carried out for evaluating the steam generator level behavior for determination of turbine runback rate on COPs trip for Yonggwang 1 and 2 Power Uprating Units. The steam generator water level evaluation program for YGN1 and 2 (SLEP-Y1) has been developed for it. The program includes models for the steam generator water level response. SLEP-Y1 is programmed with advanced continuous system simulation language (ACSL). The language has been used to simulate physical systems as a commercial tool used to evaluate system designs

  4. Levels of {sup 137}Cs and {sup 40}K in marine superficial sediments near the Angra Nuclear Power Plant (Angra dos Reis, SE Brazil)

    Energy Technology Data Exchange (ETDEWEB)

    Lima Ferreira, Paulo Alves de; Farina Amorim, Lais; Marone Tura, Pedro; Medeiros Zacheo, Valter Andre; Lopes Figueira, Rubens Cesar [Universidade de Sao Paulo (IO-USP), SP (Brazil). Inst. Oceanografico

    2015-07-01

    This study evaluated the spatial distribution of two environmentally relevant radionuclides, {sup 137}Cs and {sup 40}K, in marine superficial sediments around the Angra Nuclear Power Plant, the only Brazilian nuclear power plant complex, thus establishing a baseline for bottom sediments, given the international importance of environmental monitoring around nuclear facilities. It was observed that these radionuclides are mostly present in the muddy sediments as a result of their stronger association with its fine-grained fraction, and that their lowest levels are located around the liquid effluent discharge of the plant, as a consequence of the prevented deposition of fine sediments due to the strong discharge water flux. The comparison of the {sup 137}Cs activities in the region with other locations in the world showed that the presence of this artificial nuclide is due to the atmospheric fallout from past nuclear tests made during the Cold War, not to the nuclear power plant activities.

  5. Levels of 137Cs and 40K in marine superficial sediments near the Angra Nuclear Power Plant (Angra dos Reis, SE Brazil)

    International Nuclear Information System (INIS)

    Lima Ferreira, Paulo Alves de; Farina Amorim, Lais; Marone Tura, Pedro; Medeiros Zacheo, Valter Andre; Lopes Figueira, Rubens Cesar

    2015-01-01

    This study evaluated the spatial distribution of two environmentally relevant radionuclides, 137 Cs and 40 K, in marine superficial sediments around the Angra Nuclear Power Plant, the only Brazilian nuclear power plant complex, thus establishing a baseline for bottom sediments, given the international importance of environmental monitoring around nuclear facilities. It was observed that these radionuclides are mostly present in the muddy sediments as a result of their stronger association with its fine-grained fraction, and that their lowest levels are located around the liquid effluent discharge of the plant, as a consequence of the prevented deposition of fine sediments due to the strong discharge water flux. The comparison of the 137 Cs activities in the region with other locations in the world showed that the presence of this artificial nuclide is due to the atmospheric fallout from past nuclear tests made during the Cold War, not to the nuclear power plant activities.

  6. Reducing scram frequency by modifying/eliminating steam generator low-low level reactor trip setpoint for Maanshan nuclear power plant

    International Nuclear Information System (INIS)

    Yuann, R.Y.; Chiang, S.C.; Hsiue, J.K.; Chen, P.C.

    1987-01-01

    The feasibility of modification/elimination of steam generator low-low level reactor trip setpoint is evaluated by using RETRAN-02 code for the purpose of reducing scram frequency in Maanshan 3-loop pressurized water reactor. The ANS Condition II event loss of normal feedwater and condition IV event feedwater system line break are the basis for steam generator low-low level reactor trip setpoint sensitivity analysis, including various initial reactor power levels, reactivity feedback coefficients, and system functions assumptions etc., have been performed for the two basis events with steam generator low-low level reactor trip setpoint at 0% narrow range and without this trip respectively. The feasibility of modifying/eliminating current steam generator low-low level reactor trip setpoint is then determined based on whether the analysis results meet with the ANS Condition II and IV acceptance criteria or not

  7. Procedures and applications to enlarge the level 1+ PSA to internal fires in German nuclear power plants

    International Nuclear Information System (INIS)

    Berg, H.P.; Breiling, G.; Hoffmann, H.H.

    1997-01-01

    Investigations have shown that the consequences from fires in nuclear power plants can be significant. Methodologies considering fire in probabilistic safety analyses have been evolving in the last few years. In order to provide a basis for further discussions on benefits and limits of such an analysis in Germany, current methods are investigated. As a result a qualitative screening process is proposed to identify critical fire zones followed by a quantitative event tree analysis in which the fire caused frequency of initiating events and different core damage states will be determined. The models and data proposed for a probabilistic fire risk analysis have been successfully applied in complete and partial fire risk assessments in German nuclear power plants

  8. Lower hybrid current drive and heating experiments at the 1 MW rf power level on Alcator C

    International Nuclear Information System (INIS)

    Porkolab, M.; Lloyd, B.; Schuss, J.J.

    1983-07-01

    Lower hybrid current drive experiments were carried out in the density range 1.0 x 10 13 less than or equal to anti n(cm -3 ) less than or equal to 1.0 x 10 14 , at magnetic fields 6.0 less than or equal to B(T) less than or equal to 10. Using one 16 waveguide array, plasma currents of 150 to 200 kA have been driven by rf powers up to 600 kW for times greater than 100 msec at anti n/sub e/ up to 5 x 10 13 cm -3 . With two arrays at anti n/sub e/ approx. = 4.3 x 10 13 cm -3 at B/sub T/ = 10 T, plasma currents of 160 kA have been maintained by the rf power for 300 msec with zero loop voltage and constant internal inductance

  9. The influence of vapor superheating on the level of heat regeneration in a subcritical ORC coupled with gas power plant

    Science.gov (United States)

    Wiśniewski, Sławomir; Borsukiewicz-Gozdur, Aleksandra

    2010-09-01

    The authors presented problems related to utilization of exhaust gases of the gas turbine unit for production of electricity in an Organic Rankine Cycle (ORC) power plant. The study shows that the thermal coupling of ORC cycle with a gas turbine unit improves the efficiency of the system. The undertaken analysis concerned four the so called "dry" organic fluids: benzene, cyclohexane, decane and toluene. The paper also presents the way how to improve thermal efficiency of Clausius-Rankine cycle in ORC power plant. This method depends on applying heat regeneration in ORC cycle, which involves pre-heating the organic fluid via vapour leaving the ORC turbine. As calculations showed this solution allows to considerably raise the thermal efficiency of Clausius-Rankine cycle.

  10. Use of cost benefit analysis methodology in the meaning of motorization level from small and medium hydroelectric power plants

    International Nuclear Information System (INIS)

    Mazzon, J.G.; Simoes, N.S.; Ramos, D.S.; Ishida, S.

    1989-01-01

    The technical and economic justifications that bringing the waterfall division reformulation between Lucas Nogueira Garcez Plant and Capivara Plant in Paranapanema River (Brazil) are described, including a comparative economic of Canoas (Alta), Canoas I and Canoas II passages, motorization study and energetic benefits. The reasons of the Bulbo turbines choice and dimensioning definition of the installed power by the new reference economic parameters are also presented. (C.G.C.). 5 refs, 11 tabs

  11. Selection of quality assurance programme levels for nuclear power plants. Present practice in Canada and future developments

    International Nuclear Information System (INIS)

    Thomas, R.A.

    1982-01-01

    According to the IAEA Code of Practice on the subject and also to numerous national standards, effective quality assurance (QA) for safety in nuclear power plants depends upon the application of a number of fundamental principles. One of these principles is that QA for systems, components and structures should be commensurate with the individual importance to safety of each item. Evidently, money spent on excessive QA may be partly or wholly wasted, while too little QA will provide insufficient confidence that an item will perform satisfactorily in service. To deal successfully with the requirement of 'importance to safety', a detailed methodology must be established, by means of which QA can be prescribed rationally and consistently. Set in the context of the Canadian nuclear power and nuclear standards programmes, two related methodologies which account for importance to safety as well as for some other specific factors have been developed and are in use. These related methodologies are applied to the manufacture and installation of safety-related items, and are based on the implementation of the fixed-step, graded standards of the Canadian Standards Association, CSA Z299. Information is presented on the main features of the methodologies and on Canadian nuclear power plant QA practice in general. (author)

  12. The design and development of CO2 medium-level laser power calibration system for industrial and medical applications in Thailand

    Science.gov (United States)

    Nontapot, Kanokwan

    2018-03-01

    The carbon dioxide laser (CO2 laser) is one of the most useful and is the highest CW laser at the present. The laser produces infrared light at 10.6 um. Due to its high power, CO2 lasers are usually used in industrial applications such as cutting and welding, or for engraving at less power. CO2 lasers are also used widely in medical applications, such as laser surgery, skin resurfacing, and removing mold, due to water (biological tissue) absorb light at this wavelength very well. CO2 lasers are also used as LIDAR laser source for military range finding applications because of the transparency of the atmosphere to infrared light. Due to the increasing use of CO2 lasers laser in industrial and medical applications in Thailand, the National Institute of Metrology (Thailand) has set up a CO2 laser power calibration system and provide calibration service to customers this year. The service support calibration of medium-level laser power at wavelength of 10.6 um and at power range 100 mW-10W. The design and development of the calibration system will be presented.

  13. The level of air pollution in the impact zone of coal-fired power plant (Karaganda City) using the data of geochemical snow survey (Republic of Kazakhstan)

    Science.gov (United States)

    Adil'bayeva, T. E.; Talovskaya, A. V.; Yazikov, Ye G.; Matveenko, I. A.

    2016-09-01

    Coal-fired power plants emissions impact the air quality and human health. Of great significance is assessment of solid airborne particles emissions from those plants and distance of their transportation. The article presents the results of air pollution assessment in the zone of coal-fired power plant (Karaganda City) using snow survey. Based on the mass of solid airborne particles deposited in snow, time of their deposition on snow at the distance from 0.5 to 4.5 km a value of dust load has been determined. It is stated that very high level of pollution is observed at the distance from 0.5 to 1 km. there is a trend in decrease of dust burden value with the distance from the stacks of coal-fired power plant that may be conditioned by the particle size and washing out smaller ash particles by ice pellets forming at freezing water vapour in stacks of the coal-fired power plant. Study in composition of solid airborne particles deposited in snow has shown that they mainly contain particulates of underburnt coal, Al-Si- rich spheres, Fe-rich spheres, and coal dust. The content of the particles in samples decreases with the distance from the stacks of the coal-fired power plant.

  14. Evaluation of training programs and entry-level qualifications for nuclear-power-plant control-room personnel based on the systems approach to training

    International Nuclear Information System (INIS)

    Haas, P.M.; Selby, D.L.; Hanley, M.J.; Mercer, R.T.

    1983-09-01

    This report summarizes results of research sponsored by the US Nuclear Regulatory Commission (NRC) Office of Nuclear Regulatory Research to initiate the use of the Systems Approach to Training in the evaluation of training programs and entry level qualifications for nuclear power plant (NPP) personnel. Variables (performance shaping factors) of potential importance to personnel selection and training are identified, and research to more rigorously define an operationally useful taxonomy of those variables is recommended. A high-level model of the Systems Approach to Training for use in the nuclear industry, which could serve as a model for NRC evaluation of industry programs, is presented. The model is consistent with current publically stated NRC policy, with the approach being followed by the Institute for Nuclear Power Operations, and with current training technology. Checklists to be used by NRC evaluators to assess training programs for NPP control-room personnel are proposed which are based on this model

  15. Comparison of Field Measurements and EMT Simulation Results on a Multi-Level STATCOM for Grid Integration of London Array Wind Power Plant

    DEFF Research Database (Denmark)

    Glasdam, Jakob; Kocewiak, Łukasz Hubert; Hjerrild, Jesper

    2014-01-01

    Simulation results are widely used in the design of electrical systems such as offshore wind power plants (OWPPs) and for determination of grid compliance. Measurements constitute an important part in the evaluation process of the OWPP, including passive and active components such as the static...... of the STATCOM for wind power integration, as well as of the validity of applying a generic model of the STATCOM without knowledge of the actual implemented control system. The proposed model is integrated into an aggregated EMT model of LAOWPP, which will be used to investigate possible resonance phenomena...... that will be shown in the paper to affect the harmonic distortion level. The STATCOM distortion level will be shown to be highly affected by the number of wind turbine generators (WTGs) in service. It will be shown that the inclusion of band rejection filters (BRFs) in the WTGs’ control loop lowers the STATCOM...

  16. Improving the power of an efficacy study of a social and emotional learning program: application of generalizability theory to the measurement of classroom-level outcomes.

    Science.gov (United States)

    Mashburn, Andrew J; Downer, Jason T; Rivers, Susan E; Brackett, Marc A; Martinez, Andres

    2014-04-01

    Social and emotional learning programs are designed to improve the quality of social interactions in schools and classrooms in order to positively affect students' social, emotional, and academic development. The statistical power of group randomized trials to detect effects of social and emotional learning programs and other preventive interventions on setting-level outcomes is influenced by the reliability of the outcome measure. In this paper, we apply generalizability theory to an observational measure of the quality of classroom interactions that is an outcome in a study of the efficacy of a social and emotional learning program called The Recognizing, Understanding, Labeling, Expressing, and Regulating emotions Approach. We estimate multiple sources of error variance in the setting-level outcome and identify observation procedures to use in the efficacy study that most efficiently reduce these sources of error. We then discuss the implications of using different observation procedures on both the statistical power and the monetary costs of conducting the efficacy study.

  17. Evaluation of training programs and entry-level qualifications for nuclear-power-plant control-room personnel based on the systems approach to training

    Energy Technology Data Exchange (ETDEWEB)

    Haas, P M; Selby, D L; Hanley, M J; Mercer, R T

    1983-09-01

    This report summarizes results of research sponsored by the US Nuclear Regulatory Commission (NRC) Office of Nuclear Regulatory Research to initiate the use of the Systems Approach to Training in the evaluation of training programs and entry level qualifications for nuclear power plant (NPP) personnel. Variables (performance shaping factors) of potential importance to personnel selection and training are identified, and research to more rigorously define an operationally useful taxonomy of those variables is recommended. A high-level model of the Systems Approach to Training for use in the nuclear industry, which could serve as a model for NRC evaluation of industry programs, is presented. The model is consistent with current publically stated NRC policy, with the approach being followed by the Institute for Nuclear Power Operations, and with current training technology. Checklists to be used by NRC evaluators to assess training programs for NPP control-room personnel are proposed which are based on this model.

  18. Brain-derived neurotrophic factor (BDNF) serum basal levels is not affected by power training in mobility-limited older adults - A randomized controlled trial.

    Science.gov (United States)

    Hvid, L G; Nielsen, M K F; Simonsen, C; Andersen, M; Caserotti, P

    2017-07-01

    Brain-derived neurotrophic factor (BDNF) is a potential important factor involved in neuroplasticity, and may be a mediator for eliciting adaptations in neuromuscular function and physical function in older individuals following physical training. As power training taxes the neural system to a very high extent, it may be particularly effective in terms of eliciting increases in systemic BDNF levels. We examined the effects of 12weeks of power training on mature BDNF (mBDNF) and total BDNF (tBDNF) in mobility-limited older adults from the Healthy Ageing Network of Competence (HANC) study. We included 47 older men and women: n=22 in the training group (TG: progressive high intensity power training, 2 sessions per week; age 82.7±5.4years, 55% women) and n=25 in the control group (CG: no interventions; age 82.2±4.5years, 76% women). Following overnight fasting, basal serum levels of mBDNF and tBDNF were assessed (human ELISA kits) at baseline and post-intervention. At baseline, mBDNF and tBDNF levels were comparable in the two groups, TG and CG. Post-intervention, no significant within-group or between-group changes were observed in mBDNF or tBDNF. Moreover, when divided into responder tertiles based upon changes in mBDNF and tBDNF (i.e. decliners, maintainers, improvers), respectively, comparable findings were observed for TG and CG. Altogether, basal systemic levels of serum mBDNF and tBDNF are not affected in mobility-limited older adults following 12-weeks of power training, and do not appear to be a major mechanistic factor mediating neuroplasticity in mobility-limited older adults. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Validation of a novel wearable, wireless technology to estimate oxygen levels and lactate threshold power in the exercising muscle.

    Science.gov (United States)

    Farzam, Parisa; Starkweather, Zack; Franceschini, Maria A

    2018-04-01

    There is a growing interest in monitoring muscle oxygen saturation (SmO 2 ), which is a localized measure of muscle oxidative metabolism and can be acquired continuously and noninvasively using near-infrared spectroscopy (NIRS) methods. Most NIRS systems are cumbersome, expensive, fiber coupled devices, with use limited to lab settings. A novel, low cost, wireless, wearable has been developed for use in athletic training. In this study, we evaluate the advantages and limitations of this new simple continuous-wave (CW) NIRS device with respect to a benchtop, frequency-domain near-infrared spectroscopy (FDNIRS) system. Oxygen saturation and hemoglobin/myoglobin concentration in the exercising muscles of 17 athletic individuals were measured simultaneously with the two systems, while subjects performed an incremental test on a stationary cycle ergometer. In addition, blood lactate concentration was measured at the end of each increment with a lactate analyzer. During exercise, the correlation coefficients of the SmO 2 and hemoglobin/myoglobin concentrations between the two systems were over 0.70. We also found both systems were insensitive to the presence of thin layers of varying absorption, mimicking different skin colors. Neither system was able to predict the athletes' lactate threshold power accurately by simply using SmO 2 thresholds. Instead, the proprietary software of the wearable device was able to predict the athletes' lactate threshold power within half of one power increment of the cycling test. These results indicate this novel wearable device may provide a physiological indicator of athlete's exertion. © 2018 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  20. A research on the environmental impact on nearby waters range at low-level radioactive waste water drain from the Dayawan nuclear power station

    International Nuclear Information System (INIS)

    Zhang Chunling; Xu Zitu; Xiao Zhang.

    1987-01-01

    The possible influence of the low-level radioactive waste water drain from the Dayawan nuclear power station upon nearby waters range is discussed. The contents of the article contains the numerical simulation on tidal currents and pollutant diffusion, the calculation of concentration distribution of radioactive contaminants in the water area and of polluted field, and the criterion on radioactive contaminant influence on nearby residents and aquatic biologicals. The result shows that when the Dayawan nuclear power station is on normal operation and after the low-level radioactive waste water has been drained off into the sea, the radioactive concentration is even lower than the natural background radiation just out-side the area of about 4 km 2 round the water outlet. As a result, it won't cause any danger to the water environment. Due to the fact that the concentration of the low-level radioactive waste water from the nuclear power station fully accords with the national standard GB4792-84 and the sea water quality sandard GBH2, 3-82. It is no harm to either residents and aquatic biologicals or ecological balance

  1. Experimentation of RT-LOTOS for a critical function of a power plant instrumentation and control system; Experimentation de RT-LOTOS pour une fonction critique d`un systeme de controle-commande en centrale

    Energy Technology Data Exchange (ETDEWEB)

    Andriantsiiferana, L.; Courtiat, J.P.; De Oliveira, R.C.

    1996-01-01

    This document is the final report of the contract between LAAS-CNRS and the EdF Direction of Researches and Studies about the experimentation of RT-LOTOS formal description technique on a critical function of a nuclear power plant instrumentation and control system. This report comprises 4 parts: part 1 describes the RT-LOTOS (Real Time-Language of Temporal Ordering Specifications) tutorial and its RTL tool environment, the different RT-LOTOS operators and semantics, and the RTL tool main functionalities; part 2 deals with the methodology and the global architecture for the specification and validation of the CCT (Central Calculator for Treatment); part 3 gives more details about the different processes identified in the specification architecture and presents the main results obtained for the validation of the nominal functioning; part 4 describes some exceptional situations and shows how some failures and their associated recovery mechanisms can be modelled. (J.S.). 6 refs., 53 figs., 5 tabs., 2 appends.

  2. A bi-level stochastic scheduling optimization model for a virtual power plant connected to a wind–photovoltaic–energy storage system considering the uncertainty and demand response

    International Nuclear Information System (INIS)

    Ju, Liwei; Tan, Zhongfu; Yuan, Jinyun; Tan, Qingkun; Li, Huanhuan; Dong, Fugui

    2016-01-01

    Highlights: • Our research focuses on Virtual Power Plant (VPP). • Virtual Power Plant consists of WPP, PV, CGT, ESSs and DRPs. • Robust optimization theory is introduced to analyze uncertainties. • A bi-level stochastic scheduling optimization model is proposed for VPP. • Models are built to measure the impacts of ESSs and DERPs on VPP operation. - Abstract: To reduce the uncertain influence of wind power and solar photovoltaic power on virtual power plant (VPP) operation, robust optimization theory (ROT) is introduced to build a stochastic scheduling model for VPP considering the uncertainty, price-based demand response (PBDR) and incentive-based demand response (IBDR). First, the VPP components are described including the wind power plant (WPP), photovoltaic generators (PV), convention gas turbine (CGT), energy storage systems (ESSs) and demand resource providers (DRPs). Then, a scenario generation and reduction frame is proposed for analyzing and simulating output stochastics based on the interval method and the Kantorovich distance. Second, a bi-level robust scheduling model is proposed with a double robust coefficient for WPP and PV. In the upper layer model, the maximum VPP operation income is taken as the optimization objective for building the scheduling model with the day-ahead prediction output of WPP and PV. In the lower layer model, the day-ahead scheduling scheme is revised with the actual output of the WPP and PV under the objectives of the minimum system net load and the minimum system operation cost. Finally, the independent micro-grid in a coastal island in eastern China is used for the simulation analysis. The results illustrate that the model can overcome the influence of uncertainty on VPP operations and reduce the system power shortage cost by connecting the day-ahead scheduling with the real-time scheduling. ROT could provide a flexible decision tool for decision makers, effectively addressing system uncertainties. ESSs could

  3. Detailed description of an SSAC at the facility level for on-load refueled power reactor facilities

    International Nuclear Information System (INIS)

    Jones, R.J.

    1985-11-01

    The purpose of this document is to provide a detailed description of a system for the accounting for and control of nuclear material in an on-load refueled power reactor facility which can be used by a facility operator to establish his own system to comply with a national system for nuclear material accounting and control and to facilitate application of IAEA safeguards. The scope of this document is limited to descriptions of the following SSAC elements: (1) Nuclear Material Measurements; (2) Measurement Quality; (3) Records and Reports; (4) Physical Inventory Taking; (5) Material Balance Closing

  4. FACTORS RELATED TO SELF-EDUCATIONAL POWER IN NURSING STUDENTS : With the Focus on the Level of Self-esteem

    OpenAIRE

    酒井, 明子

    2000-01-01

    The purpose of the present study was to determine how the level of self-esteem affects the ability to educate oneself. We researched the 89 students in a nursing school. The results were as follows; 1. Self-education IV was significantly related to self-esteem, which was an important concept as the psychological foundation of self-educational power. 2. Students with high levels of self-esteem tended to be highly capable of educating themselves, whereas students with lower of self-esteem tende...

  5. Corrosion product behaviour in the Loviisa nuclear power plant primary coolant: measures taken to lower radiation levels by modified shutdown procedures

    International Nuclear Information System (INIS)

    Jaernstroem, R.T.

    1983-01-01

    The primary circuit chemistry of the Loviisa nuclear power plant differs in some respects from the concepts commonly used in PWRs. In general, Loviisa 1, which is now in its sixth cycle, and Loviisa 2, which is in its second refuelling and maintenance shutdown (October 1982), are very clean compared with several other PWRs and it seems to be possible to keep the radiation levels low and even reduce them by using correct chemistry during operation; the shutdown conditions seem to have great influence on this matter. These modified shutdown conditions and their influence on radiation levels, dose rates and radwaste buildup are discussed. (author)

  6. Energy matching and optimization analysis of waste to energy CCHP (combined cooling, heating and power) system with exergy and energy level

    International Nuclear Information System (INIS)

    Gao, Penghui; Dai, Yanjun; Tong, YenWah; Dong, Pengwei

    2015-01-01

    CCHP (combined cooling, heating and power) system as a poly-generation technology has received an increasing attention in field of small scale power systems for applications ranging from residence to utilities. It will also play an important role in waste to energy application for megacities. However, how to evaluate and manage energy utilization of CCHP scientifically remains unclear. In this paper, energy level and exergy analysis are implemented on energy conversion processes to reveal the variation of energy amount and quality in the operation of CCHP system. Moreover, based on the energy level analysis, the methodology of energy matching and optimization for the CCHP system is proposed. By this method, the operational parameters of CCHP system can be deduced to obtain an efficient performance and proper energy utilization. It will be beneficial to understand and operate the CCHP system, and to provide a guiding principle of the energy conversion and management for the CCHP system. - Highlights: • Energy level is implemented to reveal the energy variation of CCHP system. • A mathematical energy level analysis model of CCHP system is proposed. • By energy level analysis between supply and demand, optimal zone is obtained. • This study will be useful for energy matching and optimization of CCHP system

  7. Physicochemical changes and microbial inactivation after high-intensity ultrasound processing of prebiotic whey beverage applying different ultrasonic power levels.

    Science.gov (United States)

    Guimarães, Jonas T; Silva, Eric Keven; Alvarenga, Verônica O; Costa, Ana Letícia R; Cunha, Rosiane L; Sant'Ana, Anderson S; Freitas, Monica Q; Meireles, M Angela A; Cruz, Adriano G

    2018-06-01

    In this work, we investigated the effects of the ultrasonic power (0, 200, 400 and 600 W) on non-thermal processing of an inulin-enriched whey beverage. We studied the effects of high-intensity ultrasound (HIUS) on microbial inactivation (aerobic mesophilic heterotrophic bacteria (AMHB), total and thermotolerant coliforms and yeasts and molds), zeta potential, microstructure (optical microscopy, particle size distribution), rheology, kinetic stability and color. The non-thermal processing applying 600 W of ultrasonic power was comparable to high-temperature short-time (HTST) treatment (75 °C for 15 s) concerning the inactivation of AMHB and yeasts and molds (2 vs 2 log and 0.2 vs 0.4 log, respectively), although HIUS has reached a lower output temperature (53 ± 3 °C). The HIUS was better than HTST to improve beverage kinetic stability, avoiding phase separation, which was mainly attributed to the decrease of particles size, denaturation of whey proteins and gelation of polysaccharides (inulin and gellan gum). Thus, non-thermal processing by HIUS seems to be an interesting technology for prebiotic dairy beverages production. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Levels and patterns of polycyclic aromatic hydrocarbons in fly ash generated in Coal-fired power plant

    International Nuclear Information System (INIS)

    Ajmal, P.Y.; Sahu, S.K.; Pandit, G.G.; Shukla, V.K.; Puranik, V.D.

    2005-01-01

    The burning of pulverized coal to produce energy for generation of electricity in thermal power plants results in huge quantity of coal ash of varying properties. Because of the increase in electricity production, the amount of ash produced will increase proportionally. A large percentage of coal fly ash is comprised of relatively inert materials, such as silica and other trace and toxic elements. The coal ash also contain organic constituents of potential environmental concern. So far, very few studies on characterization of organic constituents in fly ash have been reported in the literature. In the present study, the fly ashes generated from the power stations are investigated regarding the distribution of 14 PAHs. The total amount of PAHs in the fly ash samples varied between 45.8 ng/g and 257.7 ng/g. Lower molecular weight (MW) PAHs, were found to be predominant in the fly ash samples. The concentration of Benzo(a)pyrene, which is the most potent carcinogenic PAH was found to vary between 0.8 ng/g to 6.3 ng/g with a mean concentration of 2.5 ng/g. (author)

  9. Human reliability analysis approach to level 1 PSA - shutdown and low power operation of Mochovce NPP, Unit 1, Slovakia

    International Nuclear Information System (INIS)

    Stojka, Tibor; Holy, Jaroslav

    2003-01-01

    The paper presents general approach, used methods and form of documentation of the results as have been applied within the Human Reliability Analysis (HRA) task of the shutdown and low power PSA (SPSA) study for Mochovce nuclear power plant, Unit 1, Slovakia. The paper describes main goals of the HRA task within the SPSA project, applied methods and data sources. Basic steps of the HRA task and human errors (HE) classification are also specified in its first part. The main part of the paper deals with pre-initiator human errors, human-induced initiators and response to initiator human errors. Since the expert judgment method (SLIM) was used for the last type of human errors probability assessment, also related activities are described including preparation works (performance shaping factors (PSFs) selection, development of PSF classification tables, preparation of aid tools for interview with plant experts), qualitative analysis (sources of information and basic steps) and quantitative analysis itself (human errors classification for final quantification including criteria used for the classification, description of structure of the spreadsheet used for quantification and treatment with dependencies). The last part of the paper describes form of documentation of the final results and provides some findings. (author)

  10. The BOS-X approach: achieving drastic cost reduction in CPV through holistic power plant level innovation

    Science.gov (United States)

    Plesniak, A.; Garboushian, V.

    2012-10-01

    In 2011, the Amonix Advanced Technology Group was awarded DOE SunShot funding in the amount of 4.5M to design a new Balance of System (BOS) architecture utilizing Amonix MegaModules™ focused on reaching the SunShot goal of 0.06-$0.08/kWhr LCOE. The project proposal presented a comprehensive re-evaluation of the cost components of a utility scale CPV plant and identified critical areas of focus where innovation is needed to achieve cost reduction. As the world's premier manufacturer and most experienced installer of CPV power plants, Amonix is uniquely qualified to lead a rethinking of BOS architecture for CPV. The presentation will focus on the structure of the BOS-X approach, which looks for the next wave of cost reduction in CPV through evaluation of non-module subsystems and the interaction between subsystems during the lifecycle of a solar power plant. Innovation around nonmodule components is minimal to date because CPV companies are just now getting enough practice through completion of large projects to create ideas and tests on how to improve baseline designs and processes. As CPV companies increase their installed capacity, they can utilize an approach similar to the methodology of BOS-X to increase the competitiveness of their product. Through partnership with DOE, this holistic approach is expected to define a path for CPV well aligned with the goals of the SunShot Initiative.

  11. Differences in Power Structures Regarding Access to Natural Resources at the Village Level in Central Sulawesi (Indonesia

    Directory of Open Access Journals (Sweden)

    Jan Barkmann

    2008-01-01

    Full Text Available The mountain forests of the Indonesian province of Central Sulawesi include core areas of the global Wallacea biodiversity “hotspot”. Remote sensing data indicated that deforestation rates around Central Sulawesi’s Lore-Lindu National Park differ more strongly between villages than could be explained by differences in the individual characteristics of the village households as assessed by quantitative village censuses. This setting provided the background for a study into inter-village differences in power structures regarding access to natural resources. Our results are abstracted from 3*10 semi-structured, qualitative interviews with key informants from the leading groups of autochthonous and migrant households of three contrasting villages. In village A, nearly feudal power relationships are exerted by a group of local “first settler” families that dominate formal village leadership as well as the influential Council of Traditional Leaders (Lembaga Adat, and that restrict deforestation and land transactions. No such institutional restrictions exist in village C. Traditional power relationships are replaced by economic power based on petty capitalist type production of the international agricultural commodity cocoa. Deforestation is muchhigher in village C. In village B, traditional institutions and power structures still appear in place although land transactions are less restricted than in village A, resulting also in high deforestation rates. While contrasting problematic social effects, our study highlights the potential efficacy of traditional institutions in the regulation of access to resources. ----- Die Bergregenwälder Zentralsulawesis sind Teil des globalen Wallacea-Biodiversität-"Hotspots" und beheimaten viele endemische Tier- und Pflanzenarten. Die Entwaldung im Bereich des dortigen Lore-Lindu Nationalparks unterscheidet sich zwischen umliegenden Dörfern stärker, als dies durch quantitative Haushaltsdaten zu erkl

  12. A Refined Self-Tuning Filter-Based Instantaneous Power Theory Algorithm for Indirect Current Controlled Three-Level Inverter-Based Shunt Active Power Filters under Non-sinusoidal Source Voltage Conditions

    Directory of Open Access Journals (Sweden)

    Yap Hoon

    2017-02-01

    Full Text Available In this paper, a refined reference current generation algorithm based on instantaneous power (pq theory is proposed, for operation of an indirect current controlled (ICC three-level neutral-point diode clamped (NPC inverter-based shunt active power filter (SAPF under non-sinusoidal source voltage conditions. SAPF is recognized as one of the most effective solutions to current harmonics due to its flexibility in dealing with various power system conditions. As for its controller, pq theory has widely been applied to generate the desired reference current due to its simple implementation features. However, the conventional dependency on self-tuning filter (STF in generating reference current has significantly limited mitigation performance of SAPF. Besides, the conventional STF-based pq theory algorithm is still considered to possess needless features which increase computational complexity. Furthermore, the conventional algorithm is mostly designed to suit operation of direct current controlled (DCC SAPF which is incapable of handling switching ripples problems, thereby leading to inefficient mitigation performance. Therefore, three main improvements are performed which include replacement of STF with mathematical-based fundamental real power identifier, removal of redundant features, and generation of sinusoidal reference current. To validate effectiveness and feasibility of the proposed algorithm, simulation work in MATLAB-Simulink and laboratory test utilizing a TMS320F28335 digital signal processor (DSP are performed. Both simulation and experimental findings demonstrate superiority of the proposed algorithm over the conventional algorithm.

  13. Ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model

    Science.gov (United States)

    2012-01-01

    Background Ultrasonic scalpel (UC) and monopolar electrocautery (ME) are common tools for soft tissue dissection. However, morphological data on the related tissue alteration are discordant. We developed an automatic device for standardized sample excision and compared quality and depth of morphological changes caused by UC and ME in a pig model. Methods 100 tissue samples (5 × 3 cm) of the abdominal wall were excised in 16 pigs. Excisions were randomly performed manually or by using the self-constructed automatic device at standard power levels (60 W cutting in ME, level 5 in UC) for abdominal surgery. Quality of tissue alteration and depth of coagulation necrosis were examined histopathologically. Device (UC vs. ME) and mode (manually vs. automatic) effects were studied by two-way analysis of variance at a significance level of 5%. Results At the investigated power level settings UC and ME induced qualitatively similar coagulation necroses. Mean depth of necrosis was 450.4 ± 457.8 μm for manual UC and 553.5 ± 326.9 μm for automatic UC versus 149.0 ± 74.3 μm for manual ME and 257.6 ± 119.4 μm for automatic ME. Coagulation necrosis was significantly deeper (p < 0.01) when UC was used compared to ME. The mode of excision (manual versus automatic) did not influence the depth of necrosis (p = 0.85). There was no significant interaction between dissection tool and mode of excision (p = 0.93). Conclusions Thermal injury caused by UC and ME results in qualitatively similar coagulation necrosis. The depth of necrosis is significantly greater in UC compared to ME at investigated standard power levels. PMID:22361346

  14. Power Talk

    DEFF Research Database (Denmark)

    Stefanovic, Cedomir; Popovski, Petar; Angjelichinoski, Marko

    2015-01-01

    We introduce a novel communication strategy for DC Micro Grids (MGs), termed power talk, in which the devices communicate by modulating the power levels in the DC bus. The information is transmitted by varying the parameters that the MG units use to control the level of the common bus voltage...

  15. Activity Levels of 210Po in the Coastal Area of Kapar, Malaysia, Close to a Coal-Fired Power Plant

    International Nuclear Information System (INIS)

    Asnor Azrin Sabuti; Che Abd Rahim Mohamed

    2012-01-01

    The activity concentration of 210 Po from six different samples consisting of raw charcoal, surface sediment, rainwater (suspended solids (SSrw) and dissolved phase (Drw) and estuarine water (suspended solids (SSew) and dissolved phase (Dew)), were analyzed. The activity concentration of 210 Po in solid samples was between 7.63 ± 0.67 and 744.28 ± 21.12 Bqkg -1 and in dissolved samples varied between 0.34 ± 0.03 and 86.33 ± 6.51 mBqL -1 . On average, 210 Po activity in SSrw sample was the highest, at nearly three times its original form (charcoal). SSew and surface sediment samples were similarly distributed between 15 th March and 1 st August samplings, but were relatively lower than charcoal and SSrw samples. The natural meteorological variability also enhanced 210 Po distribution and dispersion to a few kilometers from the coal-fired power plant. (author)

  16. Detailed description of an SSAC at the facility level for light water moderated (off-load refueled) power reactor facilities

    International Nuclear Information System (INIS)

    Jones, R.J.

    1985-03-01

    This report is intended to provide the technical details of an effective State Systems of Accounting for and Control of Nuclear Material (SSAC) which Member States may use, if they wish, to establish and maintain their SSACs. It is expected that systems designed along the lines described would be effective in meeting the objectives of both national and international systems for nuclear material accounting and control. This document accordingly provides a detailed description of a system for the accounting for and control of nuclear material in an off-load refueled light water moderated power reactor facility which can be used by a facility operator to establish his own system to comply with a national system for nuclear material accounting and control and to facilitate application of IAEA safeguards. The scope of this document is limited to descriptions of the following elements: (1) Nuclear Material Measurements; (2) Measurement Quality; (3) Records and Reports; (4) Physical Inventory Taking; (5) Material Balance Closing

  17. Maximum power point tracking for photovoltaic applications by using two-level DC/DC boost converter

    Science.gov (United States)

    Moamaei, Parvin

    Recently, photovoltaic (PV) generation is becoming increasingly popular in industrial applications. As a renewable and alternative source of energy they feature superior characteristics such as being clean and silent along with less maintenance problems compared to other sources of the energy. In PV generation, employing a Maximum Power Point Tracking (MPPT) method is essential to obtain the maximum available solar energy. Among several proposed MPPT techniques, the Perturbation and Observation (P&O;) and Model Predictive Control (MPC) methods are adopted in this work. The components of the MPPT control system which are P&O; and MPC algorithms, PV module and high gain DC-DC boost converter are simulated in MATLAB Simulink. They are evaluated theoretically under rapidly and slowly changing of solar irradiation and temperature and their performance is shown by the simulation results, finally a comprehensive comparison is presented.

  18. 14C levels in the vicinity of the Fukushima Dai-ichi Nuclear Power Plant prior to the 2011 accident

    DEFF Research Database (Denmark)

    Xu, Sheng; Cook, Gordon T.; Cresswell, Alan J.

    2016-01-01

    A 50-year-old Japanese cedar (Cryptomeria japonica) from Okuma, ∼1 km southwest of the Fukushima Dai-ichi Nuclear Power Plant, was cored and each annual ring was analysed for 14C. The 14C specific activity values varied from 330.4 Bq kg−1 C in the tree ring formed in 1971 to 231.2 Bq kg−1 C...... discharges from the reactors during their normal operations. In addition, the specific activities are positively correlated with the annual electricity generation values. The excess 14C specific activities were effective dose of ... ingestion pathway in the study location. The primary wind direction is east-southeast/southeast with a frequency of ∼30%, in comparison to ∼20% frequency for the direction of the site under study (north-northeast/northeast). This would tend to indicate a similar magnitude of additional effective dose...

  19. Temporal evolution of the 3H levels in the surface waters around the Almaraz Nuclear Power Plant

    International Nuclear Information System (INIS)

    Baeza, A.; del Rio, L.M.; Garcia, E.; Jimenez, A.; Miro, C.; Paniagua, J.M.; Rufo, M.

    1997-01-01

    We have quantified the evolution during 1994 of the impact on the Tagus river of liquid releases of 3 H (51.3TBq in the cited year), originating from the functioning of the Almaraz Nuclear Power Plant, and conditioned by the management of the cooling reservoir water. Taking into account, on the one hand, that tritiated water is hydrodynamically indistinguishable from untritiated water when both form part of the same mass of liquid,and, on the other, the practically null stratification and forced circulation of the water in the cited cooling reservoir, together with the hydrological fluxes interchanged between the said reservoir and the Tagus river (which is entirely regulated in the section under study and, because of prolonged drought, had a relatively small flow during the study period), we were able to model satisfactorily the temporal evolution of the 3 H activity in the cooling reservoir. (author)

  20. 75 FR 24755 - DTE ENERGY; Enrico Fermi Atomic Power Plant Unit 1; Exemption From Certain Low-Level Waste...

    Science.gov (United States)

    2010-05-05

    ... rubble and debris are generated that require shipment for disposal in offsite low-level radioactive waste... decommissioning Fermi-1 and radioactive waste shipments from the site are ongoing and expected to increase over... to the volume of radioactive waste; licensees have encountered an increase in the number of routine...

  1. Impact of High Levels of Wind Penetration on the Exercise of Market Power in the Multi-Area Systems

    NARCIS (Netherlands)

    Moiseeva, E.

    2017-01-01

    New European energy policies have set a goal of a high share of renewable energy in electricity markets. In the presence of high levels of renewable generation, and especially wind, there is more uncertainty in the supply. It is natural, that volatility in energy production induces the volatility in

  2. Synergistic Success: The Power of Mentorship and Reaching the Senior Levels of the U.S. Army

    Science.gov (United States)

    2017-06-09

    2011, 50). Combined with the loss of manufacturing jobs in inner cities, the black community viewed attaining a skill to remain competitive in the... communication and team-building skills improving organizational performance. Barriers to Effective Mentorship Effective mentorship takes trust and time...level (National Center for Veterans Analysis and Statistics 2017). Creating value and building self - esteem will influence African American officers

  3. Estimation of directivity and sound power levels emitted by aircrafts during taxiing, for outdoor noise prediction purpose

    NARCIS (Netherlands)

    Asensio, C.; Pavón, I.; Ruiz, M.; Pagan Munoz, Raul; Recuero, M.

    2007-01-01

    Integrated noise model (INM) is the most internationally used software to calculate noise levels near airports. Take off, landing or pass by operations can be modeled by INM, but it does not consider aircrafts taxiing, which, in some cases, can be important to accurately evaluate and reduce

  4. Foreign programs for the storage of spent nuclear power plant fuels, high-level waste canisters and transuranic wastes

    International Nuclear Information System (INIS)

    Harmon, K.M.; Johnson, A.B. Jr.

    1984-04-01

    The various national programs for developing and applying technology for the interim storage of spent fuel, high-level radioactive waste, and TRU wastes are summarized. Primary emphasis of the report is on dry storage techniques for uranium dioxide fuels, but data are also provided concerning pool storage

  5. The Power of Relationship Building in International Short-Term Field Study Experiences at the Graduate Level

    Science.gov (United States)

    Davis, Brittany; Coryell, Joellen E.

    2016-01-01

    This paper derives from a case study of a 10-day cross-cultural field study experience held in Italy in which graduate students from master and doctoral levels in adult education participated. During group reflections, several students who participated in the course expressed the value of learning through personal connections made with students as…

  6. Brain-derived neurotrophic factor (BDNF) serum basal levels is not affected by power training in mobility-limited older adults - A randomized controlled trial

    DEFF Research Database (Denmark)

    Hvid, Lars G; Nielsen, Martin KF; Simonsen, Casper

    2017-01-01

    high extent, it may be particularly effective in terms of eliciting increases in systemic BDNF levels. We examined the effects of 12 weeks of power training on mature BDNF (mBDNF) and total BDNF (tBDNF) in mobility-limited older adults from the Healthy Ageing Network of Competence (HANC) study. We......Brain-derived neurotrophic factor (BDNF) is a potential important factor involved in neuroplasticity, and may be a mediator for eliciting adaptations in neuromuscular function and physical function in older individuals following physical training. As power training taxes the neural system to a very...... included 47 older men and women: n = 22 in the training group (TG: progressive high intensity power training, 2 sessions per week; age 82.7 ± 5.4 years, 55% women) and n = 25 in the control group (CG: no interventions; age 82.2 ± 4.5 years, 76% women). Following overnight fasting, basal serum levels of m...

  7. Power distribution and substrate noise coupling investigations on the behavioral level for photon counting imaging readout circuits

    International Nuclear Information System (INIS)

    Lundgren, Jan; Abdalla, Suliman; O'Nils, Mattias; Oelmann, Bengt

    2007-01-01

    In modern mixed-signal system design, there are increasing problems associated with noise coupling caused by switching digital parts to sensitive analog parts. As a consequence, there is a growing necessity to understand these problems. In order to avoid costly design iterations, noise coupling simulations should be initiated as early as possible in the design chain. The problems associated with on-chip noise coupling have been discovered in photon counting pixel detector readout systems, where the level of integration of analog and digital circuits is very high on a very small area, and it would appear that these problems will continue to increase for future system designs in this field. This paper deals with the functionality of utilizing behavioral level models for simulating noise coupling in these readout systems. The methods and models are described and simulation results are shown for a photon counting pixel detector readout system

  8. Estimation of an Effective Young’s Modulus of Elasticity in the Locality of the Gabčíkovo Hydrology Power Plant by Geometric Leveling

    Directory of Open Access Journals (Sweden)

    Mojzeš Marcel

    2015-03-01

    Full Text Available The Gabčíkovo hydroelectric power plant is located in a complicated geological environment (gravel sub-soil and a high groundwater level. Excavation work started after the withdrawal of water in the autumn of 1984 and lasted until the autumn of 1986. A basic geodetic control network with a special monument was founded before the excavation work began. This network served for the setting-out of the hydroelectric power plant as well as for the control of the excavation work. The repeated geodetic control measurements have been evaluated and presented at many seminars and conferences. Monitoring the horizontal and vertical stability of the geodetic control network during the general site excavation showed significant horizontal and vertical deformations. The paper is focused on an estimation of an effective Young's modulus of elasticity in the area studied.

  9. Improvement of level-1 PSA computer code package - Modeling and analysis for dynamic reliability of nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Hoon; Baek, Sang Yeup; Shin, In Sup; Moon, Shin Myung; Moon, Jae Phil; Koo, Hoon Young; Kim, Ju Shin [Seoul National University, Seoul (Korea, Republic of); Hong, Jung Sik [Seoul National Polytechnology University, Seoul (Korea, Republic of); Lim, Tae Jin [Soongsil University, Seoul (Korea, Republic of)

    1996-08-01

    The objective of this project is to develop a methodology of the dynamic reliability analysis for NPP. The first year`s research was focused on developing a procedure for analyzing failure data of running components and a simulator for estimating the reliability of series-parallel structures. The second year`s research was concentrated on estimating the lifetime distribution and PM effect of a component from its failure data in various cases, and the lifetime distribution of a system with a particular structure. Computer codes for performing these jobs were also developed. The objectives of the third year`s research is to develop models for analyzing special failure types (CCFs, Standby redundant structure) that were nor considered in the first two years, and to complete a methodology of the dynamic reliability analysis for nuclear power plants. The analysis of failure data of components and related researches for supporting the simulator must be preceded for providing proper input to the simulator. Thus this research is divided into three major parts. 1. Analysis of the time dependent life distribution and the PM effect. 2. Development of a simulator for system reliability analysis. 3. Related researches for supporting the simulator : accelerated simulation analytic approach using PH-type distribution, analysis for dynamic repair effects. 154 refs., 5 tabs., 87 figs. (author)

  10. Effects of power densities, continuous and pulse frequencies, and number of sessions of low-level laser therapy on intact rat brain.

    Science.gov (United States)

    Ilic, Sanja; Leichliter, Sandra; Streeter, Jackson; Oron, Amir; DeTaboada, Luis; Oron, Uri

    2006-08-01

    The aim of the present study was to investigate the possible short- and long-term adverse neurological effects of low-level laser therapy (LLLT) given at different power densities, frequencies, and modalities on the intact rat brain. LLLT has been shown to modulate biological processes depending on power density, wavelength, and frequency. To date, few well-controlled safety studies on LLLT are available. One hundred and eighteen rats were used in the study. Diode laser (808 nm, wavelength) was used to deliver power densities of 7.5, 75, and 750 mW/cm2 transcranially to the brain cortex of mature rats, in either continuous wave (CW) or pulse (Pu) modes. Multiple doses of 7.5 mW/cm2 were also applied. Standard neurological examination of the rats was performed during the follow-up periods after laser irradiation. Histology was performed at light and electron microscopy levels. Both the scores from standard neurological tests and the histopathological examination indicated that there was no long-term difference between laser-treated and control groups up to 70 days post-treatment. The only rats showing an adverse neurological effect were those in the 750 mW/cm2 (about 100-fold optimal dose), CW mode group. In Pu mode, there was much less heating, and no tissue damage was noted. Long-term safety tests lasting 30 and 70 days at optimal 10x and 100x doses, as well as at multiple doses at the same power densities, indicate that the tested laser energy doses are safe under this treatment regime. Neurological deficits and histopathological damage to 750 mW/cm2 CW laser irradiation are attributed to thermal damage and not due to tissue-photon interactions.

  11. Systematic evaluation of a secondary method for measuring diagnostic-level medical ultrasound transducer output power based on a large-area pyroelectric sensor

    Science.gov (United States)

    Zeqiri, B.; Žauhar, G.; Rajagopal, S.; Pounder, A.

    2012-06-01

    A systematic study of the application of a novel pyroelectric technique to the measurement of diagnostic-level medical ultrasound output power is described. The method exploits the pyroelectric properties of a 0.028 mm thick membrane of polyvinylidene fluoride (PVDF), backed by an acoustic absorber whose ultrasonic absorption coefficient approaches 1000 dB cm-1 at 3 MHz. When exposed to an ultrasonic field, absorption of ultrasound adjacent to the PVDF-absorber interface results in heating and the generation of a pyroelectric output voltage across gold electrodes deposited on the membrane. For a sensor large enough to intercept the whole of the acoustic beam, the output voltage can be calibrated for the measurement of acoustic output power. A number of key performance properties of the method have been investigated. The technique is very sensitive, with a power to voltage conversion factor of typically 0.23 V W-1. The frequency response of a particular embodiment of the sensor in which acoustic power reflected at the absorber-PVDF interface is subsequently returned to the pyroelectric membrane to be absorbed, has been evaluated over the frequency range 1.5 MHz to 10 MHz. This has shown the frequency response to be flat to within ±4%, above 2.5 MHz. Below this frequency, the sensitivity falls by 20% at 1.5 MHz. Linearity of the technique has been demonstrated to within ±1.6% for applied acoustic power levels from 1 mW up to 120 mW. A number of other studies targeted at assessing the achievable measurement uncertainties are presented. These involve: the effects of soaking, the influence of the angle of incidence of the acoustic beam, measurement repeatability and sensitivity to transducer positioning. Additionally, over the range 20 °C to 30 °C, the rate of change in sensitivity with ambient temperature has been shown to be +0.5% °C-1. Implications of the work for the development of a sensitive, traceable, portable, secondary method of ultrasound output power

  12. The influence of power and actor relations on priority setting and resource allocation practices at the hospital level in Kenya: a case study.

    Science.gov (United States)

    Barasa, Edwine W; Cleary, Susan; English, Mike; Molyneux, Sassy

    2016-09-30

    Priority setting and resource allocation in healthcare organizations often involves the balancing of competing interests and values in the context of hierarchical and politically complex settings with multiple interacting actor relationships. Despite this, few studies have examined the influence of actor and power dynamics on priority setting practices in healthcare organizations. This paper examines the influence of power relations among different actors on the implementation of priority setting and resource allocation processes in public hospitals in Kenya. We used a qualitative case study approach to examine priority setting and resource allocation practices in two public hospitals in coastal Kenya. We collected data by a combination of in-depth interviews of national level policy makers, hospital managers, and frontline practitioners in the case study hospitals (n = 72), review of documents such as hospital plans and budgets, minutes of meetings and accounting records, and non-participant observations in case study hospitals over a period of 7 months. We applied a combination of two frameworks, Norman Long's actor interface analysis and VeneKlasen and Miller's expressions of power framework to examine and interpret our findings RESULTS: The interactions of actors in the case study hospitals resulted in socially constructed interfaces between: 1) senior managers and middle level managers 2) non-clinical managers and clinicians, and 3) hospital managers and the community. Power imbalances resulted in the exclusion of middle level managers (in one of the hospitals) and clinicians and the community (in both hospitals) from decision making processes. This resulted in, amongst others, perceptions of unfairness, and reduced motivation in hospital staff. It also puts to question the legitimacy of priority setting processes in these hospitals. Designing hospital decision making structures to strengthen participation and inclusion of relevant stakeholders could

  13. Detection of low-level environmental exposure rates due to noble gas releases from the Muehleberg nuclear power plant

    International Nuclear Information System (INIS)

    Czarnecki, J.; Volkle, H.; Pretre, S.

    1980-01-01

    The increase of radiation doses in the vicinity of the Swiss Nuclear Power Stations due to airborne releases is generally expected to be below one mrem/year (about one percent of the natural radiation dose). To prove this expected rate, long term measurements with pressure ionization chambers in the vicinity of the Muhleberg plant (BWR) were conducted. Two of these chambers were installed at places where the greatest dose rates from the noble gas plumes were expected in the two prevailing wind directions. The local dose rates were continuously registered on magnetic tape to allow minicomputer evaluation. After the fuel change in the summer of 1976 the noble gas releases from Muhleberg dropped considerably. From that time the noble gas releases consisted of a very low continuous component and some rare short-time spike compoments resulting from turbine and reactor trips. The dose due to the low continuous component was determined by correlating the dose rates at the measuring points with the release measure--ments at the stack and with weather conditions, and by subtracting the natural background. The short noble gas spikes lasted from minutes to some hours and caused small dose rate increases which were easily measured with the ionization chambers, and usually amounted to doses of some microroentgens. By further correlating these dose peaks with wind direction and stack emission measurements, determination of short time atmospheric dilution factors for existing weather situations became possible. By this process, the very low annual environmental doses in the range of 1 mrem per year were determined. (author)

  14. Pre operational levels of 137Cs and 90Sr in seawater and sea foods in Gulf of Mannar near Kudankulam Nuclear Power Plant

    International Nuclear Information System (INIS)

    Vijayakumar, B.; Thomas, G.; Rajan, P.S.; Selvi, B.S.; Balamurugan, M.; Ravi, P.M.; Tripathy, R.M.

    2014-01-01

    The first unit of Kudankulam Nuclear Power Project (KKNPP) attained first criticality on July 13, 2013 and synchronized to the grid on October 22, 2013. The first unit achieved the full rated power of 1000 MWe on June 7, 2014. The second unit of KKNPP is under advanced stage of commissioning and hot run of the plant is expected shortly. Commercial operational of the first unit is expected soon. It is imperative to establish the pre operational levels of Fall out nuclides like 137 Cs and 90 Sr in and around Kudankulam site, especially sea waters and sea food samples as these nuclides are produced in the reactor as fission products. Nevertheless, they are retained in the fuel matrix itself as the reactors host a multiple layered barrier to prevent the escape of these radionuclides into the environment by adopting the philosophy of defense in depth. Benchmarking the levels of these nuclides in the aquatic domain will help in future comparison of the levels of these nuclides after the plants start operation in addition to generating the regional database in south eastern tip of the sea

  15. Income Trends of Residential PV Adopters: An analysis of household-level income estimates [PowerPoint presentation

    Energy Technology Data Exchange (ETDEWEB)

    Barbose, Galen L.; Darghouth, Naim R.; Hoen, Ben; Wiser, Ryan H.

    2018-04-09

    The residential photovoltaic (PV) market has expanded rapidly over the past decade, but questions exist about how equitably that growth has occurred across income groups. Prior studies have investigated this question but are often limited by narrow geographic study regions, now-dated analysis timeframes, or coarse estimates of PV-adopter incomes. At the same time, a spate of new programs and initiatives, as well as innovations in business models and product design, have emerged in recent years with the aim of making solar more accessible and affordable to broader segments of the population. Yet, many of those efforts are proceeding without robust underlying information about the income characteristics of recent residential PV adopters. This work aims to establish basic factual information about income trends among U.S. residential solar adopters, with some emphasis on low- and moderate-income (LMI) households. The analysis is unique in its relatively extensive coverage of the U.S. solar market, relying on Berkeley Lab’s Tracking the Sun dataset, which contains project-level data for the vast majority of all residential PV systems in the country (a subset of which are ultimately included in the analysis sample). This analysis is also unique in its use of household-level income estimates that provide a more-precise characterization of PV-adopter incomes than in most prior studies.

  16. Investigation on the use digital controls instead of PID analog controls in the level control of steam generators of nuclear power PWR

    International Nuclear Information System (INIS)

    Alvarenga, Marco Antonio Bayout

    2012-01-01

    The aim of this study is to identify current alternatives for the implementation of digital controllers in the level control of steam generators of nuclear power PWR (Pressurized Water Reaetor). It is intended to identify the types of digital controls that are available from the theoretical and conceptual viewpoints for this purpose. We investigate the advantages and disadvantages of each controller model. From this assessment are pointed the most suitable models in hierarchical scale. This evaluation also serves to suggest possible types of control installation as a whole, where the level control of the steam generators becomes just one of many controls that are part of the plant. In this case, the use of digital controls allows the non-linear and multivariable treatment which is characteristic of complex systems, such as the nuclear power generation. The treatment of nonlinearities and multivariable aspects allows a more detailed study of the stability of these plants when they are subject to transients or several accidents, such as the case of losing external power of transients. In the specific case of steam generators, the instabilities result from the emergence of the shrink and swell phenomenas, depending on the load variations of thermonuclear plant. The application of several types and digital controllers, considering these inherent characteristics of the level control of steam generators, allows to infer which types of controllers are more appropriate to treat instabilities of this type and to make conjectures in its use for the cases of more complex instabilities, considering the integration of all nucleus-plant controls.

  17. Implementation of a Sage-Based Stirling Model Into a System-Level Numerical Model of the Fission Power System Technology Demonstration Unit

    Science.gov (United States)

    Briggs, Maxwell H.

    2011-01-01

    The Fission Power System (FPS) project is developing a Technology Demonstration Unit (TDU) to verify the performance and functionality of a subscale version of the FPS reference concept in a relevant environment, and to verify component and system models. As hardware is developed for the TDU, component and system models must be refined to include the details of specific component designs. This paper describes the development of a Sage-based pseudo-steady-state Stirling convertor model and its implementation into a system-level model of the TDU.

  18. Prediction for the high-level alpha-active waste to be generated by nuclear power stations in the Member States of the European Communities

    International Nuclear Information System (INIS)

    Schmidt, E.

    1977-04-01

    Starting with a forecast for the nuclear power generating capacity to be installed in the Member States of the European Communities before the end of this century, a prediction is made of the annual production of high-level alpha-active waste from reprocessing plants and the corresponding accumulation up to the year 2000. The isotopic composition of the alpha-active waste from individual reactor types was calculated and an estimation of the influence of recycling plutonium through light water reactors on the produced quantity of higher actinides is made

  19. An inexact bi-level simulation–optimization model for conjunctive regional renewable energy planning and air pollution control for electric power generation systems

    International Nuclear Information System (INIS)

    Chen, Yizhong; He, Li; Li, Jing; Cheng, Xi; Lu, Hongwei

    2016-01-01

    Highlights: • Detailed model developed for power generation and pollutants mitigation. • Dynamic integration of bi-level programming with uncertainty analyses. • Application of the novel bi-level model for EPS in Fengtai District. • Development of renewable energy under different probability levels. - Abstract: In this study, an IBSOM (inexact bi-level simulation–optimization model) is developed for conjunctive regional renewable energy planning and air pollution control for EPS (electric power systems) under uncertainty. The IBSOM integrates techniques of CFMTVW (combined forecasting model with time-varying weights), ILP (interval linear programming), MIP (mixed integer programming), CCP (chance-constrained programming), as well as BLP (bi-level programming) into a general framework. In the IBSOM, uncertainties expressed as interval and stochastic parameters within multi-period and multi-option contexts can be effectively tackled. In addition, a leader-follower decision strategy is incorporated into the optimization process where two non-competitive objectives are sequentially proposed, with the environmental sector dominating the upper-level objective (leader’s one) and the energy sector providing the lower-level objective (follower’s one). To solve the proposed model, an improved bi-level interactive solution algorithm based on satisfactory degree is introduced into the decision-making process for balancing to what extent the constraints are met and the objective reaches its optima. Then, the IBSOM is applied to a real-world case study of EPS in Fengtai District, Beijing, China. Interval solutions associated with renewable energy development, electricity generation, facility-expansion scheme, as well as pollutants mitigation can be obtained under different system-violation risk. Results indicate that a higher violation risk would lead to a decreased strictness of the constraints or an expanded decision space, which results in the decreased system

  20. Development of an alarm analysis system based on multi-level flow models for nuclear power plant

    International Nuclear Information System (INIS)

    Zhang Jiande; Yang Ming; Zhang Zhijian

    2008-01-01

    An alarm analysis system based on Multi-level Flow Models (MFM) was developed for a PWR NPP. By automatically identifying the primary root causes in complex fault situations, the workload of the operators can be reduced. In addition, because MFM also provides a set of graphical symbols that implies causalities, operators can confirm diagnosis results by semiotic analysis, and hence the understandability of the process of alarm analysis as well as the reliability of maintenance task can be increased. 19 cases of simulation data from RELAP5/MOD2 code were utilized for evaluating the performance of the proposed system. The simulation results show that the proposed alarm analysis system has a good ability to detect and diagnose accidents earlier in time before reactor trip. (authors)

  1. Disposal of high-level waste from nuclear power plants in Denmark. Salt dome investigations. v.1

    International Nuclear Information System (INIS)

    1981-01-01

    A summary is presented of a report in five volumes on possible disposal of radioactive waste in Denmark. The investigation was made by the Danish electric utilities ELKRAFT and ELSAM at the request of the Danish Government. The investigation proved it possible to consider two alternative designs for a disposal facility, one based on the deposition of waste in individual, deep holes, the other on placing the waste in mine galleries. A safety analysis was completed with the Mors dome as example. The purpose of the analysis was to prove whether safe disposal of high-level waste in Denmark was feasible. The utilities concluded that the results of the analysis were satisfactory and the report is now being assessed by the authorities. (BP)

  2. Disposal of high-level waste from nuclear power plants in Denmark. Salt dome investigations. v.4

    International Nuclear Information System (INIS)

    1981-01-01

    The present report deals with construction, operation and sealing of disposal facilities for high-level waste in a salt dome. It is volume 4 of five volumes that together constitute the final report on the Danish utilities' salt dome investigations. The safety investigations were carried out for a deep-hole disposal facility located in the salt dome on Mors. In principle the results of the investigations also apply to a shaft/mine disposal facility. The facility is designed for the disposal of vitrified high-level waste in the shape of glass canisters. There is a low concentration of waste in each canister, approx. 10%. Furthermore, it was selected to place the waste in an intermediate storage for about 40 years prior to its final disposal. Consequently, heat generation in the waste at the time of final disposal will be modest, resulting in low temperature increase in the salt. As an example, the highest temperature increase will be approx. 40 deg. C. and it will occur at the edge of the hole five years after disposal has taken place. Prior to disposal, the glass canisters are encased in steel casks with 15 cm thick walls. Three canisters are placed in each cask, and 215 casks are stacked on top on one another in each deep-hole from a depth of 1200 m to 2500 m underground. The additional encasing is designed to protect the glass from dissolution should any brine reach the disposal facility. Furthermore, the steel cask protects the glass canisters against pressure from the wall of the hole. The technical design of the disposal facility gives it a considerable safety margin against unexpected events. The investigations proved Cretaceous strata to constitute an effective secondary barrier that would prevent radioactive matter from travelling from the underlying disposal facility to the biosphere. (BP)

  3. Scheme for generation of fully-coherent, TW power level hard X-ray pulses from baseline undulators at the European X-ray FEL

    International Nuclear Information System (INIS)

    Geloni, Gianluca; Kocharyan, Vitali; Saldin, Evgeni

    2010-07-01

    The most promising way to increase the output power of an X-ray FEL (XFEL) is by tapering the magnetic field of the undulator. Also, significant increase in power is achievable by starting the FEL process from a monochromatic seed rather than from noise. This report proposes to make use of a cascade self-seeding scheme with wake monochromators in a tunable-gap baseline undulator at the European XFEL to create a source capable of delivering coherent radiation of unprecedented characteristics at hard X-ray wavelengths. Compared with SASE X-ray FEL parameters, the radiation from the new source has three truly unique aspects: complete longitudinal and transverse coherence, and a peak brightness three orders of magnitude higher than what is presently available at LCLS. Additionally, the new source will generate hard X-ray beam at extraordinary peak (TW) and average (kW) power level. The proposed source can thus revolutionize fields like single biomolecule imaging, inelastic scattering and nuclear resonant scattering. The self-seeding scheme with the wake monochromator is extremely compact, and takes almost no cost and time to be implemented. The upgrade proposed in this paper could take place during the commissioning stage of the European XFEL, opening a vast new range of applications from the very beginning of operations.We present feasibility study and examplifications for the SASE2 line of the European XFEL. (orig.)

  4. First measurements of the neutrals pressure and of the degassing level of the lower hybrid antenna induced by the HF power

    International Nuclear Information System (INIS)

    Goniche, M.; Berger-By, G.; Bibet, P.; Bonnel, P.; Bruneau, J.L.; Capitain, J.J.; Gil, C.; Hertout, P.; Rodriguez, L.; Magne, R.

    1989-12-01

    Previous experiments have shown that large amounts of gas may be desorbed from the waveguides walls of a lower hybrid antenna. To reduce the pressure rise, a getter pump has been connected to the LH vessel of Tore Supra. The effective neutrals pumping speed of the LH launcher during a plasma shot has been measured for different configurations of the getter pump (inactive, low conductance and high conductance duct). For deuterium, an effective pumping speed of 33 m 3 /s was obtained. During short conditioning pulses and 2-s plasma shots, degassing rates were measured for RF power level up to 1.2 MW. With different filling gas (He, H 2 , D 2 ), degassing rates are documented and effects of conditioning are discussed. This neutrals influx contributes to the particles balance of the plasma discharge: a significant increase of the total number of particles (10-20%) and a flattening of the density profile are inferred. Large increase of the neutrals pressure in the pumped limitor (up to 32%) was also observed. For 2-s shots, this pressure rise was held below 3 mPa at an average LH power density of 1.5 kW/cm 2 . However, this pressure rise may be, to some extent, larger in the reduced-section part of the launcher which has a low conductance. It is expected that this pressure rise should not exceed 5 mPa at full power (5 KW/cm 2 ) after conditioning [fr

  5. An Ergonomic Evaluation of the Illumination Level and the Management Plan to Improve the Working Environment of Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Kwang Hyeon; Lee, Yong Hee [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-10-15

    Illumination in the working environment is one of the crucial factors that affect worker's psychological status as well as the physiological condition according to each task. Sometimes it affects the results of worker's cognitive, perceptual work performance. In particular, illumination may become a triggering factor to human errors in visual tasks due to visual fatigue through direct influence of vision in NPPs. Illumination includes several visual conditions such as uniformity factor, light distribution, glare, SPD (Surge Protector Device), flicker, illumination system, daylight and window control, in addition to the simple physical aspects of illumination and luminance. These conditions may affect operators' visibility and disillusion level, cause stress, attention, emotion, etc. and they finally affect workers' performance and errors as a result. From the many illumination conditions mentioned above, current work environment evaluation items on illumination are mainly based only on the intensity of illumination, and there is yet no systematic way with evaluation criteria for other factors such as luminance, flickering, etc. In addition, research and development on illumination emphasizes mainly the physical characteristics of illumination, and it is insufficient for the influence studies on human error or work performance that are caused by these factors

  6. An Ergonomic Evaluation of the Illumination Level and the Management Plan to Improve the Working Environment of Nuclear Power Plants

    International Nuclear Information System (INIS)

    Shin, Kwang Hyeon; Lee, Yong Hee

    2011-01-01

    Illumination in the working environment is one of the crucial factors that affect worker's psychological status as well as the physiological condition according to each task. Sometimes it affects the results of worker's cognitive, perceptual work performance. In particular, illumination may become a triggering factor to human errors in visual tasks due to visual fatigue through direct influence of vision in NPPs. Illumination includes several visual conditions such as uniformity factor, light distribution, glare, SPD (Surge Protector Device), flicker, illumination system, daylight and window control, in addition to the simple physical aspects of illumination and luminance. These conditions may affect operators' visibility and disillusion level, cause stress, attention, emotion, etc. and they finally affect workers' performance and errors as a result. From the many illumination conditions mentioned above, current work environment evaluation items on illumination are mainly based only on the intensity of illumination, and there is yet no systematic way with evaluation criteria for other factors such as luminance, flickering, etc. In addition, research and development on illumination emphasizes mainly the physical characteristics of illumination, and it is insufficient for the influence studies on human error or work performance that are caused by these factors

  7. Independent Verification Survey Of The SPRU Lower Level Hillside Area At The Knolls Atomic Power Laboratory Niskayuna, New York

    International Nuclear Information System (INIS)

    Harpenau, Evan M.; Weaver, Phyllis C.

    2012-01-01

    During August 10, 2011 through August 19, 2011, and October 23, 2011 through November 4, 2011, ORAU/ORISE conducted verification survey activities at the Separations Process Research Unit (SPRU) site that included in-process inspections, surface scans, and soil sampling of the Lower Level Hillside Area. According to the Type-B Investigation Report, Sr-90 was the primary contributor to the majority of the activity (60 times greater than the Cs-137 activity). The evaluation of the scan data and sample results obtained during verification activities determined that the primary radionuclide of concern, Sr-90, was well below the agreed upon soil cleanup objective (SCO) of 30 pCi/g for the site. However, the concentration of Cs-137 in the four judgmental samples collected in final status survey (FSS) Units A and B was greater than the SCO. Both ORAU and aRc surveys identified higher Cs-137 concentrations in FSS Units A and B; the greatest concentrations were indentified in FSS Unit A

  8. Characterization of the Transient Response of the ILS with One Module Installed to Heatup Changes in Power Level and Cooldown

    International Nuclear Information System (INIS)

    K. G. Condie; C. M. Stoots; J. E. O'Brien; J. S. Herring

    2007-01-01

    This report provides documentation of the initial startup and testing of the first electrolysis module in the Idaho National Laboratory (INL) High Temperature Steam Electrolysis Integrated Laboratory Scale (ILS) facility. Initial shakedown testing of the INL ILS experimental facility commenced on August 22, 2007. This fulfilled a DOE Level 2 milestone. Heatup of the first ILS module started at approximately 4:10 PM on September 24, 2007. Initial module testing continued for 420 hours. The test average H2 production rate was approximately 1.3 Nm3/hr (0.116 kg H2/hr), with a peak measured value of over 2 Nm3/hr (0.179 kg H2/hr). Significant module performance degradation was observed over the first 250 hours, after which no further degradation was noted for the remainder of the test. Once all test objectives had been successfully met, the test was terminated in a controlled fashion. Discussion is included concerning several modifications that will be incorporated into the facility components to improve reliability and ease of operation for future long term testing

  9. Disposal of high-level waste from nuclear power plants in Denmark. Salt dome investigations. v.2

    International Nuclear Information System (INIS)

    1981-01-01

    The present report deals with the geological investigations performed for determing the feasibility of a repository for high-level waste in a salt dome. It is volume 2 of five volumes that together constitute the final report of the Danish utilities' salt dome investigations. The purpose of the work was to procure a more detailed knowledge of the geology of salt domes in North Jutland on example of Mors. The Mors dome is oval with the two axes of approx. 12.5 km and 8 km respectively. Two deep wells have been drilled into the salt. These wells reach 3400-3500 m below surface. Until a depth of about 3200 m Erslev 2 passes through rock salt of Zechstein 1 which is the oldest evaporite series. However, it could also be interlayed with the slightly younger Zechstein 2. At about 3200 m a marker layer was met with Zechstein 2 salt below. Interpretation of cores and results of downhole electromagnetic and borehole gravimetric measurements show that there is a large area around Erslev 2 which consists of very pure sodium chloride with traces of anhydrite (calcium, sulphate) 1-3%. This area is used for the repository design and safety evaluation. The hydrological conditions existing in the strata above the salt dome (caprock) have been investigated with the help of four hydrogeological wells, placed two each, on two different sites. The cores themselves were taken at various depths in all four holes. With these laboratory methods it has been possible to measure data relevant to hydrology - such as porosity and permeability - as well as geochemistry. (BP)

  10. Power and polarization dependences of ultra-narrow electromagnetically induced absorption (EIA) spectra of 85 Rb atoms in degenerate two-level system

    Science.gov (United States)

    Qureshi, Muhammad Mohsin; Rehman, Hafeez Ur; Noh, Heung-Ryoul; Kim, Jin-Tae

    2016-05-01

    We have investigated ultra-narrow EIA spectral features with respect to variations of polarizations and powers of pump laser beam in a degenerate two-level system of the transition of 85 Rb D2 transition line. Polarizations of the probe laser beam in two separate experiments were fixed at right circular and horizontal linear polarizations, respectively while the polarizations of the pump lasers were varied from initial polarizations same as the probe laser beams to orthogonal to probe polarizations. One homemade laser combined with AOMs was used to the pump and probe laser beams instead of two different lasers to overcome broad linewidths of the homemade lasers. Theoretically, probe absorption coefficients have been calculated from optical Bloch equations of the degenerate two level system prepared by a pump laser beam. In the case of the circular polarization, EIA signal was obtained as expected theoretically although both pump and probe beams have same polarization. The EIA signal become smaller as power increases and polarizations of the pump and probe beams were same. When the polarization of the pump beam was linear polarization, maximum EIA signal was obtained theoretically and experimentally. Experimental EIA spectral shapes with respect to variations of the pump beam polarization shows similar trends as the theoretical results.

  11. Disposal of high-level waste from nuclear power plants in Denmark. Salt dome investigations. v.5

    International Nuclear Information System (INIS)

    1981-01-01

    The present report deals with safety evaluation as part of the investigations regarding a repository for high-level waste in a salt dome. It is volume 5 of five volumes that together constitute the final report on the Danish utilities' salt dome investigations. Two characteristics of the waste are of special importance for the safety evaluation: the encasing of the waste in steel casks with 15 cm thick walls affording protection against corrosion, protecting the surroundings against radiation, and protecting the glass cylinders from mechanical damage resulting from the pressure at the bottom of the disposal hole, and the modest generation of heat in the waste at the time of disposal resulting in a maximum temperature increase in the salt close to the waste of approx. 40 deg. C. These characteristics proved to considerably improve the safety margin with respect to unforeseen circumstances. The character of the salt dome and of the salt in the proposed disposal area offers in itself good protection against contact with the ground water outside the dome. The relatively large depth of 1200 and 2500 m of the salt surface also means that neither dome nor disposal facility will be appreciably influenced by glaciations or earthquakes. The chalk above the proposed disposal area is very tight and to retain radioactive matter effectively even in the precence of high concentrations of NaCL. The safety investigations included a number of natural processes and probable events such as the segregation of crystal water from overlooked salt minerals, faulty sealings of disposal holes, permeable fault zones in the chalk overlying the dome, the risk in connection with human penetration into the dome. These conditions will neither lead to the destruction of the waste casks or to the release of waste from the dome. Leaching of a cavern is the only situation which proved to result in a release of radioactive material to the biosphere, but the resulting doses was found to be small

  12. Calprotectin and TNF trough serum levels identify power Doppler ultrasound synovitis in rheumatoid arthritis and psoriatic arthritis patients in remission or with low disease activity.

    Science.gov (United States)

    Inciarte-Mundo, José; Ramirez, Julio; Hernández, Maria Victoria; Ruiz-Esquide, Virginia; Cuervo, Andrea; Cabrera-Villalba, Sonia Raquel; Pascal, Mariona; Yagüe, Jordi; Cañete, Juan D; Sanmarti, Raimon

    2016-07-08

    Serum levels of calprotectin, a major S100 leucocyte protein, are associated with disease activity in rheumatoid arthritis (RA) and psoriatic arthritis (PsA) patients. Higher drug trough serum levels are associated with good response in patients treated with tumour necrosis factor inhibitors (TNFi). Power Doppler ultrasound (PDUS) synovitis is predictive of flare and progression of structural damage in patients in clinical remission. The purpose of this study was to analyse the accuracy of calprotectin and TNFi trough serum levels in detecting PDUS synovitis in RA and PsA patients in clinical remission or with low disease activity who were receiving TNFi. We conducted a cross-sectional study of 92 patients (42 with RA, 50 with PsA) receiving adalimumab (ADA), etanercept (ETN) or infliximab who were in remission or had low disease activity (28-joint Disease Activity Score based on erythrocyte sedimentation rate ultrasound scores (all r coefficients >0.50 in RA). Calprotectin correlated with the PDUS synovitis score in patients treated with ADA and ETN. Using PDUS synovitis (yes or no) as the reference variable, calprotectin had an AUC of 0.826. The best cut-off was ≥1.66 μg/ml, with a likelihood ratio of 2.77. C-reactive protein (AUC 0.673) and erythrocyte sedimentation rate (AUC 0.731) had a lower discriminatory capacity. TNFi trough serum levels were significantly associated with PDUS synovitis (OR 0.67, 95 % CI 0.52-0.85, p < 0.001) but their accuracy (AUC <0.5) was less than that of calprotectin. TNFi trough serum levels were inversely correlated with calprotectin and PDUS synovitis in RA and PsA patients receiving ADA and ETN. Calprotectin and TNFi trough serum levels may help identify PDUS synovitis in RA and PsA patients in clinical remission or with low disease activity.

  13. Renewable energy, coal as a baseload power source, and greenhouse gas emissions: Evidence from U.S. state-level data

    International Nuclear Information System (INIS)

    Squalli, Jay

    2017-01-01

    This paper examines the relationship between renewable energy production and greenhouse gas emissions (GHG) using U.S. state-level data for 2010. After controlling for other sources of emissions, U.S. states that produce a larger share of renewable energy are found to have lower GHG emissions. It is estimated that a 10% increase in the share of renewable energy could decrease CH_4 emissions by about 0.26%. Since the use of renewable energy sources does not release GHG emissions, this effect can be interpreted as stabilizing if renewable energy is added to coal use or as corrective if it replaces coal. After accounting for the role of coal as a baseload power source, an increase in the share of renewable energy is estimated to mitigate N_2O emissions at the U.S. state level only if states individually decrease their share of coal use to levels below 41.47%. These findings have significant policy implications for the provision of guidance to policymakers in identifying optimal energy mixes and in pursuing realistic goals to enhance renewable energy penetration and to contribute to the current efforts of tackling climate change. - Highlights: • The paper examines the link between renewable energy, coal, and GHG emissions. • The analysis accounts for the role of coal as a baseload power source. • A 10% increase in renewable energy share decreases CH_4 emissions by about 0.26%. • Renewable energy can mitigate emissions if the share of coal drops below 41.47%.

  14. A high level implementation and performance evaluation of level-I asynchronous cache on FPGA

    Directory of Open Access Journals (Sweden)

    Mansi Jhamb

    2017-07-01

    Full Text Available To bridge the ever-increasing performance gap between the processor and the main memory in a cost-effective manner, novel cache designs and implementations are indispensable. Cache is responsible for a major part of energy consumption (approx. 50% of processors. This paper presents a high level implementation of a micropipelined asynchronous architecture of L1 cache. Due to the fact that each cache memory implementation is time consuming and error-prone process, a synthesizable and a configurable model proves out to be of immense help as it aids in generating a range of caches in a reproducible and quick fashion. The micropipelined cache, implemented using C-Elements acts as a distributed message-passing system. The RTL cache model implemented in this paper, comprising of data and instruction caches has a wide array of configurable parameters. In addition to timing robustness our implementation has high average cache throughput and low latency. The implemented architecture comprises of two direct-mapped, write-through caches for data and instruction. The architecture is implemented in a Field Programmable Gate Array (FPGA chip using Very High Speed Integrated Circuit Hardware Description Language (VHSIC HDL along with advanced synthesis and place-and-route tools.

  15. The obtention of high reliability levels to the increasing of power in hydroelectric generators of modern power plants; A obtencao de altos indices de confiabilidade no aumento de potencia em hidrogeradores de usinas modernizadas

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Octavio A.; Uemori, Mauro K.I.; Spiridon, Michel W. [Asea Brown Boveri Ltda., Osasco, SP (Brazil)

    1993-12-31

    The increase in the power capacity of the generators of existing hydroelectric power plants is presented as an alternative technically feasible and economically advantageous to the increase of the power generation capacity of the Brazilian electric power system. This work presents the need of a global analysis of each case in order to optimize this process and also presents a methodology which may be applied to electric power generators, turbines, transformers and other electrical equipment. 2 refs., 8 figs.

  16. Greater-than-Class C low-level radioactive waste characterization. Appendix A-2: Timing of greater-than-Class C low-level radioactive waste from nuclear power plants

    International Nuclear Information System (INIS)

    Steinke, W.F.

    1994-09-01

    Planning for the storage or disposal of greater-than-Class C low-level radioactive waste (GTCC LLW) requires characterization of that waste. Timing, or the date the waste will require storage or disposal, is an integral aspect of that planning. The majority of GTCC LLW is generated by nuclear power plants, and the length of time a reactor remains operational directly affects the amount of GTCC waste expected from that reactor. This report uses data from existing literature to develop high, base, and low case estimates for the number of plants expected to experience (a) early shutdown, (b) 40-year operation, or (c) life extension to 60-year operation. The discussion includes possible effects of advanced light water reactor technology on future GTCC LLW generation. However, the main focus of this study is timing for shutdown of current technology reactors that are under construction or operating

  17. Methodology for evaluating radiological consequences of the management of very low-level solide waste arising from decommissioning of nuclear power plants

    International Nuclear Information System (INIS)

    Smith, G.M.; Hemming, C.R.; Clark, J.M.; Chapuis, A.M.; Garbay, H.

    1985-01-01

    In this report a methodology is described, and illustrated by examples, for the evaluation of individual doses and collective dose commitments arising as a result of various management modes for very low-level solid wastes arising from the decommissioning of nuclear power plants. Estimates have been made of the masses of materials activated and contaminated to within three concentration limits, 0.37, 3.7 and 37 Bq g-1, at three times after reactor shutdown, 5 y, 25 y and 100 y. The disposal options considered are shallow land burial, at a municipal landfill site or at the reactor site, and disposal on the seabed in coastal waters or the deep ocean. It is assumed that there is no special treatment to reduce or eliminate the potential radiological hazard. Consideration has also been given to the radiological impact of recycling of contaminated steel. The radiological impacts of all the management options for the wastes considered were found to be small. It may therefore be acceptable to allow such very low-level wastes to be disposal of without special restrictions provided that the level and type of activity of the wastes can be verified. In addition the health detriment cost associated with all the management options is small, so it is likely that other factors such as transport and engineering costs will be more important in final decisions about the management of these wastes

  18. Radioactive contamination of arthropods from different trophic levels in hilly and mountainous areas after the Fukushima Daiichi nuclear power plant accident.

    Science.gov (United States)

    Tanaka, Sota; Hatakeyama, Kaho; Takahashi, Sentaro; Adati, Tarô

    2016-11-01

    In order to understand the influence of the Fukushima Daiichi nuclear power plant accident on the ecosystem in hilly and mountainous areas of Fukushima Prefecture, chronological changes in the levels of radiocesium in arthropod species were investigated. From 2012 to 2014, arthropods from different trophic levels were sampled and the air radiation dose rates at the sampling sites were analyzed. The air radiation dose rates showed a significant and constant reduction over the 2 years at the sampling sites in Fukushima. The median radiocesium concentration ( 134 Cs +  137 Cs) detected in the rice grasshopper, Oxya yezoensis, and the Emma field cricket, Teleogryllus emma, dropped continuously to 0.080 and 0.078 Bq/g fresh weight, respectively, in 2014. In contrast, no significant reduction in radioactive contamination was observed in the Jorô spider, Nephila clavata, in which the level remained at 0.204 Bq/g in 2014. A significant positive correlation between radiocesium concentration and the air radiation dose rate was observed in the rice grasshopper, the Emma field cricket and the Jorô spider. The highest correlation coefficient (ρ = 0.946) was measured in the grasshopper. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. Is the SNARC effect related to the level of mathematics? No systematic relationship observed despite more power, more repetitions, and more direct assessment of arithmetic skill.

    Science.gov (United States)

    Cipora, Krzysztof; Nuerk, Hans-Christoph

    2013-01-01

    The SNARC (spatial-numerical association of response codes) described that larger numbers are responded faster with the right hand and smaller numbers with the left hand. It is held in the literature that arithmetically skilled and nonskilled adults differ in the SNARC. However, the respective data are descriptive, and the decisive tests are nonsignificant. Possible reasons for this nonsignificance could be that in previous studies (a) very small samples were used, (b) there were too few repetitions producing too little power and, consequently, reliabilities that were too small to reach conventional significance levels for the descriptive skill differences in the SNARC, and (c) general mathematical ability was assessed by the field of study of students, while individual arithmetic skills were not examined. Therefore we used a much bigger sample, a lot more repetitions, and direct assessment of arithmetic skills to explore relations between the SNARC effect and arithmetic skills. Nevertheless, a difference in SNARC effect between arithmetically skilled and nonskilled participants was not obtained. Bayesian analysis showed positive evidence of a true null effect, not just a power problem. Hence we conclude that the idea that arithmetically skilled and nonskilled participants generally differ in the SNARC effect is not warranted by our data.

  20. A column level, low power, 1 M sample/s double ramp A/D converter for monolithic active pixel sensors in high energy physics

    International Nuclear Information System (INIS)

    Pillet, N.; Heini, S.; Hu, Y.

    2010-01-01

    Monolithic active pixel sensors (MAPS) using standard low cost CMOS technologies available from industrial manufacturers have demonstrated excellent tracking performances for minimum ionizing particles. The need for highly granular, fast, thin sensors with a full digital output drives an R and D effort, aiming to design and optimize a low power high speed A/D converter integrated at the column level. Following this main issue, a double digital ramp A/D converter has been proposed for CMOS monolithic active pixel sensors in this paper. This A/D converter responds to the constraints of size, power dissipation and precision for CMOS sensors for particle detection. It also represents a first step in order to reach the high speed of conversion needed for this kind of application. The A/D converter has a resolution of 4 bits for conversion speed of 1 M sample/s with only 264 μW of static consumption in a very particular pitch of 25 μmx900 μm.