WorldWideScience

Sample records for level monitoring station

  1. Air and radiation monitoring stations

    CERN Multimedia

    AUTHOR|(SzGeCERN)582709

    2015-01-01

    CERN has around 100 monitoring stations on and around its sites. New radiation measuring stations, capable of detecting even lower levels of radiation, were installed in 2014. Two members of HE-SEE group (Safety Engineering and Environment group) in front of one of the new monitoring stations.

  2. Water Level Station History

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Images contain station history information for 175 stations in the National Water Level Observation Network (NWLON). The NWLON is a network of long-term,...

  3. Photochemical Assessment Monitoring Stations (PAMS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — Photochemical Assessment Monitoring Stations (PAMS). This file provides information on the numbers and distribution (latitude/longitude) of air monitoring sites...

  4. Mobile environmental radiation monitoring station

    International Nuclear Information System (INIS)

    Assido, H.; Shemesh, Y.; Mazor, T.; Tal, N.; Barak, D.

    1997-01-01

    A mobile environmental radiation monitoring station has been developed and established for the Israeli Ministry of Environment. The radiation monitoring station is ready for immediate placing in any required location, or can be operated from a vehicle. The station collects data Tom the detector and transfers it via cellular communication network to a Computerized Control Center for data storage, processing, and display . The mobile station is fully controlled from the. Routinely, the mobile station responses to the data request accumulated since the last communication session. In case of fault or alarm condition in the mobile station, a local claim is activated and immediately initiates communication with the via cellular communication network. (authors)

  5. Testing of environmental radiation monitors using the Risø low-level radiation measurement stations

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.

    2000-01-01

    June, 1999. The chief aims of such experiments are to allow the participants to check their home calibrations of their detectors and to compare the responses of the individual environmental radiation measurement systems used in the different EU member states and making a link between the different...... a simulation of a radioactive plume passing over the monitors during a certain time was made using a specially designed source set up in the field that was able to vary the air kerma rate from low activity Cs-137 sources additional to the natural air kerma rate. It is demonstrated that a typical environmental...

  6. Monitoring of nuclear power stations

    International Nuclear Information System (INIS)

    Ull, E.; Labudda, H.J.

    1987-01-01

    The purpose of the invention is to create a process for undelayed automated detection and monitoring of accidents in the operation of nuclear power stations. According to the invention, this problem is solved by the relevant local measurements, such as radiation dose, components and type of radiation and additional relevant meteorological parameters being collected by means of wellknown data collection platforms, these being transmitted via transmission channels by means of satellites to suitable worldwide situated receiving stations on the ground, being processed there and being evaluated to recognise accidents. The local data collection platforms are used in the immediate vicinity of the nuclear power station. The use of aircraft, ships and balloons as data collection systems is also intended. (HWJ)

  7. ICUD-0499 Low-cost remotely sensed environmental monitoring stations

    DEFF Research Database (Denmark)

    Nielsen, Rasmus; Thorndahl, Søren Liedtke

    2017-01-01

    This study contributes with extensive research of applying low-cost remotely sensed monitoring stations to an urban environment. Design requirements are scrutinized, including applications for remote data access, hardware design, and monitoring network design. A network of 9 monitoring stations...... measuring stream water level is deployed during July 2017. Data is streamed to a web page using cellular-based data transmission. Monitoring network performance is quantified with respect to local physical and weather conditions....

  8. Development of the Arctic radionuclide monitoring station

    International Nuclear Information System (INIS)

    King, S.E.; Phillips, G.W.; Aakenes, U.R.

    1996-01-01

    In recent years, the world has learned about the dumping of nuclear reactors and other waste into the Arctic seas by the former Soviet Union. Most of the information on the present levels of radioactivity in the region has been obtained by oceanographic expeditions conducted during the brief Arctic summers. Year-round monitoring of the movement of radio-activity during dynamic seasonal and episodic chances is hampered by the difficulties caused by sea ice, logistics and communication constraints associated with deployment and maintenance of monitoring equipment in this remote region. We have designed an autonomous station to measure the benthic gamma-ray emitting radioactivity for periods of at least one year. The station is capable of detecting a 30 Bq/m 3 increase in the 137 Cs activity in a 24 hour period. After a year-long deployment, the station releases its anchor and rises to the surface to transmit the accumulated spectra and oceanographic data via an Argos satellite link. The design and performance characteristics of the prototype station will be discussed

  9. Development of the Arctic radionuclide monitoring station

    Science.gov (United States)

    King, S. E.; Aakenes, U. R.; McCoy, K.; Phillips, G. W.

    1997-06-01

    The world has learned about the dumping of nuclear reactors and other waste into the Arctic seas by the former Soviet Union. Most of the information on the present levels of radioactivity in the region has been obtained by oceanographic expeditions conducted during the brief Arctic summers. Year-round monitoring of the movement of radioactivity during dynamic seasonal and episodic changes is hampered by the difficulties caused by sea ice, logistics and communication constraints associated with deployment and maintenance of monitoring equipment in this remote region. The authors have designed an autonomous station to measure the benthic gamma-ray emitting radioactivity for periods of at least one year. The station is capable of detecting a 30 Bq/m/sup 3/ increase in the /sup 137/Cs activity in a 24 hour period. After a year-long deployment, the station releases its anchor and rises to the surface to transmit the accumulated spectra and oceanographic data via an Argos satellite link. The design and performance characteristics of the prototype station are discussed.

  10. Urban Noise Recorded by Stationary Monitoring Stations

    Science.gov (United States)

    Bąkowski, Andrzej; Radziszewski, Leszek; Dekýš, Vladimir

    2017-10-01

    The paper presents the analysis results of equivalent sound level recorded by two road traffic noise monitoring stations. The stations were located in Kielce (an example of a medium-size town in Poland) at the roads in the town in the direction of Łódź and Lublin. The measurements were carried out through stationary stations monitoring the noise and traffic of motor vehicles. The RMS values based on A-weighted sound level were recorded every 1 s in the buffer and the results were registered every 1 min over the period of investigations. The registered data were the basis for calculating the equivalent sound level for three time intervals: from 6:00 to 18:00, from 18:00 to 22:00 and from 22:00 to 6:00. Analysis included the values of the equivalent sound level recorded for different days of the week split into 24h periods, nights, days and evenings. The data analysed included recordings from 2013. The agreement of the distribution of the variable under analysis with normal distribution was evaluated. It was demonstrated that in most cases (for both roads) there was sufficient evidence to reject the null hypothesis at the significance level of 0.05. It was noted that compared with Łódź Road, in the case of Lublin Road data, more cases were recorded for which the null hypothesis could not be rejected. Uncertainties of the equivalent sound level measurements were compared within the periods under analysis. The standard deviation, coefficient of variation, the positional coefficient of variation, the quartile deviation was proposed for performing a comparative analysis of the obtained data scattering. The investigations indicated that the recorded data varied depending on the traffic routes and time intervals. The differences concerned the values of uncertainties and coefficients of variation of the equivalent sound levels.

  11. GSFC contamination monitors for Space Station

    Science.gov (United States)

    Carosso, P. A.; Tveekrem, J. L.; Coopersmith, J. D.

    1988-01-01

    This paper describes the Work Package 3 activities in the area of neutral contamination monitoring for the Space Station. Goddard Space Flight Center's responsibilities include the development of the Attached Payload Accommodations Equipment (APAE), the Polar Orbiting Platform (POP), and the Flight Telerobotic Servicer (FTS). GSFC will also develop the Customer Servicing Facility (CSF) in Phase 2 of the Space Station.

  12. Atmospheric air contamination monitoring. Monitoring station ASS-500, GIG Katowice

    International Nuclear Information System (INIS)

    Michalik, B.

    1993-01-01

    The results obtained during the period of 1991-1993 in monitoring station ASS-500 working in Katowice have been presented. The concentration of 137 Cs, 226 Ra, 40 K, 7 Be and dustiness in atmospheric air have been shown. Some proposals about the modifications of monitoring station ASS-500 have been introduced. 3 figs, 5 tabs

  13. Hawaii Munitions Monitoring Station and Natural Laboratory

    Science.gov (United States)

    Edwards, M.; Trimble, A. Z.; Rognstad, M. R.

    2017-12-01

    Hundreds of thousands of tons of conventional munitions were fired into the ocean at military ranges or deliberately disposed at sea during the twentieth century. Potential contaminants from munitions and explosives of concern (MEC) affect virtually every coast in the United States, including Alaska, the Hawaiian Islands, Guam, American Samoa and other U.S. territories as well as inland waterways. It is necessary to develop methods to assess the concentrations of munitions constituents present at a site to address concerns about the presence of environmentally relevant concentrations and their potential impacts. Having a well-characterized site to test instruments and methods is important for continued development and refinement of technology. Most sites are too big to characterize comprehensively in three dimensions over time periods lasting days or longer. We are working to develop a monitoring station and natural laboratory near Oahu, Hawaii to create a cost-effective demonstration and validation natural laboratory where emerging technologies can be evaluated and compared. Ordnance Reef (OR) is an ideal location to establish a munitions monitoring station for historical, logistical and environmental reasons. OR is an area of shallow fringing reef measuring approximately 4.2 km by 2.2 km along the Waianae coast of Oahu that was used as a disposal area for military munitions following World War II. OR has been the subject of multiple investigations including an inventory of munitions conducted by the U.S. Army Corps of Engineers in 2002 and a screening-level risk investigation conducted by the National Oceanic and Atmospheric Administration and the University of Hawaii in 2006. As a result, there are multiple datasets collected over the past fifteen years that can be leveraged to serve as a baseline for the natural laboratory. These extant datasets are being supplemented with data from integrated unmanned systems deployed at OR to characterize and visualize the

  14. Status of radionuclide monitoring stations in Australia

    International Nuclear Information System (INIS)

    Burns, P.A.

    2001-01-01

    The Australian Radiation Protection and Nuclear Safety Agency (ANSTO) first became involved in the monitoring of radionuclides in the environment in 1955 when assessing the effects on the Australian population of the radioactive releases associated with the atmospheric testing of nuclear weapons. (At that time ARPANSA was known as the Commonwealth X-ray and Radium Laboratory). The United Kingdom had tested weapons in Australia in 1952 and 1953 and in August 1954 entered into an agreement with the Australian Government to establish a test range at Maralinga in South Australia. The government established a Maralinga Safety Committee and through this Committee ARPANSA became involved in the surveillance of radioactive fallout over Australia. The primary function of this surveillance was to ensure that the nuclear trials would not adversely effect the health of the Australian population. A program was established to reliably assess the deposition of radioactive fallout over Australia so that exposure to the population could be estimated. This task was performed in conjunction with the Bureau of Meteorology and the Department of Supply. Measurements were made on daily samples of fallout dawn from 10 centres throughout Australia. A low level radiochemical facility was established in 1961 for the measurement of 90 Sr and 137 Cs in environmental samples so that the long term distribution of fallout could be tracked. In the 1960s the program was extended to measure fresh fission products reaching Australia from atmospheric testing in other countries, usually originating from test sites in the northern hemisphere. The sampling program that was established was designed so that it could be rapidly expanded when a new testing program started. At this time a permanent fallout monitoring network was established around Australia using high volume air samplers capable of sampling up to 10000 m 3 per week. Approximately six stations have been operated at any one time but the

  15. Limerick Nuclear Generating Station vibration monitoring system

    International Nuclear Information System (INIS)

    Mikulski, R.

    1988-01-01

    Philadelphia Electric Company utilizes a vibration monitoring computer system at its Limerick Nuclear Generating Station to evaluate machine performance. Performance can be evaluated through instantaneous sampling, online static and transient data. The system functions as an alarm monitor, displaying timely alarm data to the control area. The passage of time since the system's inception has been a learning period. Evaluation through continuous use has led to many enhancements in alarm handling and in the acquisition and display of machine data. Due to the system's sophistication, a routine maintenance program is a necessity. This paper describes the system's diagnostic tools and current utilization. System development and maintenance techniques will also be discussed

  16. Benzene monitoring at CPPI service stations

    International Nuclear Information System (INIS)

    Davis, C.S.

    1996-01-01

    A study was conducted in which ambient airborne concentration levels of benzene were measured at a representative set of gasoline service stations in Toronto and Vancouver. Benzene is considered to be toxic under the Canadian Environmental Protection Act (CEPA). It is a component in gasoline (0.1 to 4.7 per cent by volume) and is present in vehicle evaporative and exhaust emissions. Measurements were made every 18 days at each station for one year. The objective of the study was to assess the ambient and employee exposure levels of benzene at service stations and to determine whether the levels were typical of those published in the literature. In a 1986 PACE (Petroleum Association for Conservation of the Canadian Environment) survey of exposure to gasoline hydrocarbon vapours at Canadian service stations, airborne benzene concentration data was inconsistent with similar ambient and personal exposure data in the international literature. It was concluded that both the mean ambient benzene concentration and the personal exposure level measurements in this study were generally lower than similar measurements made in other countries. The same observation was made with respect to ambient and personal exposure levels measured in this study vis-a-vis those measured during the PACE study conducted in 1985/86. . 31 refs., 24 tabs., 5 figs

  17. Variability of road traffic noise recorded by stationary monitoring stations

    Science.gov (United States)

    Bąkowski, Andrzej; Radziszewski, Leszek

    2017-11-01

    The paper presents the analysis results of equivalent sound level recorded by two road traffic noise monitoring stations. The stations were located in Kielce (an example of a medium-size town in Poland) at the roads out of the town in the direction of Kraków and Warszawa. The measurements were carried out through stationary stations monitoring the noise and traffic of motor vehicles. The RMS values based on A-weighted sound level were recorded every 1 s in the buffer and the results were registered every 1 min over the period of investigations. The registered data were the basis for calculating the equivalent sound level for three time intervals: from 6:00 to 18:00, from 18:00 to 22:00 and from 22:00 to 6:00. Analysis included the values of the equivalent sound level recorded for different days of the week split into 24h periods, nights, days and evenings. The data analysed included recordings from 2013. The coefficient of variation and positional variation were proposed for performing comparative analysis of the obtained data scattering. The investigations indicated that the recorded data varied depending on the traffic routes. The differences concerned the values of coefficients of variation of the equivalent sound levels.

  18. A new watershed assessment framework for Nova Scotia: A high-level, integrated approach for regions without a dense network of monitoring stations

    Science.gov (United States)

    Sterling, Shannon M.; Garroway, Kevin; Guan, Yue; Ambrose, Sarah M.; Horne, Peter; Kennedy, Gavin W.

    2014-11-01

    High-level, integrated watershed assessments are a basic requirement for freshwater planning, as they create regional summaries of multiple environmental stressors for the prioritization of watershed conservation, restoration, monitoring, and mitigation. There is a heightened need for a high-level, integrated watershed assessment in Nova Scotia as it faces pressing watershed issues relating to acidification, soil erosion, acid rock drainage, eutrophication, and water withdrawals related to potential shale gas development. But because of the relative sparseness of the on-the-ground effects-based data, for example on water quality or fish assemblages, previously created approaches for integrated watershed assessment cannot be used. In a government/university collaboration, we developed a new approach that relies solely on easier-to-collect and more available exposure-based variables to perform the first high-level watershed assessment in Nova Scotia. In this assessment, a total of 295 watershed units were studied. We used Geographic Information Systems (GIS) to map and analyze 13 stressor variables that represent risks to aquatic environment (e.g., road/stream crossing density, acid rock drainage risk, surface water withdrawals, human land use, and dam density). We developed a model to link stressors with impacts to aquatic systems to serve as a basis for a watershed threat ranking system. Resource management activities performed by government and other stakeholders were also included in this analysis. Our assessment identifies the most threatened watersheds, enables informed comparisons among watersheds, and indicates where to focus resource management and monitoring efforts. Stakeholder communication tools produced by the NSWAP include a watershed atlas to communicate the assessment results to a broader audience, including policy makers and public stakeholders. This new framework for high-level watershed assessments provides a resource for other regions that also

  19. Monitoring of Electromagnetic Radiation from Cellular Base Stations in Kuwait

    International Nuclear Information System (INIS)

    Al-Otaibi, A.H.; Al-Ajmi, D.; Williams, T.; McGee, D.; Dennis, J.A.; Beg, M.U.

    1998-01-01

    A survey of the radio frequency electromagnetic environment in Kuwait was carried out. The primary purpose of this survey was to monitor electromagnetic radiation (EMR) field strength levels emitted by cellular base stations installed and operated by the Kuwait Mobile Telecommunications Company (MTC). Measurements were made at 26 cellular-phone base stations, chosen as a representative sample to include 14 school sites, 2 residential sites, 2 hospital sites, 3 ministerial building sites, 3 commercial sites and 1 typical stand-alone site. On all the selected sites measurements were made with a spectrum analyser to determine the emission level in the frequency bands used by the base station transmitters (917-960 MHz). The results indicated that total field strength, specifically due to the MTC base stations, found in public access areas, varied generally between 0.05 and 1.13 V.m -1 . These values are in the order of between 40 and 800 times lower than the new pan-European CENELEC pre-standard ENV 50166-2 'Human Exposure to Electromagnetic Fields'. In terms of power density the highest observed value (0.34 μW.m -2 ) was more than a thousand times below the prescribed standards. (author)

  20. Personal exposure versus monitoring station data for respirable particles

    Energy Technology Data Exchange (ETDEWEB)

    Sega, K; Fugas, M

    1982-01-01

    Personal exposure to respirable particles of 12 subjects working at the same location, but living in various parts of Zagreb, was monitored for 7 consecutive days and compared with simultaneously obtained data from the outdoor network station nearest to subject's home. Although personal exposure is related to the outdoor pollution, other sources play a considerable role. Indoor exposure takes, on the average, more than 80% of the total time. The ratio between average personal exposure and respirable particle levels in the outdoor air decreases with the increased outdoor concentration (r = -0.93), indicating that this relationship might serve as a basis for a rough estimate of possible personal exposure.

  1. Environmental radiation monitoring system in nuclear power station

    International Nuclear Information System (INIS)

    Matsuoka, Sadazumi; Tadachi, Katsuo; Endo, Mamoru; Yuya, Hiroshi

    1983-01-01

    At the time of the construction of nuclear power stations, prior to their start of operation, the state of environmental radiation must be grasped. After the start of the power stations, based on those data, the system of environmental radiation monitoring is established. Along with the construction of Kashiwazaki-Kariwa Nuclear Power Station, The Tokyo Electric Power Co., Inc. jointly with Fujitsu Ltd. has developed a high-reliability, environmental radiation monitoring system, and adopted ''optical data highways'' using optical fiber cables for communication. It consists of a central monitoring station and 11 telemeter observation points, for collecting both radiation and meteorological data. The data sent to the central station through the highways are then outputted on a monitoring panel. They are analyzed with a central processor, and the results are printed out. (Mori, K.)

  2. Monitoring Your Blood Sugar Level

    Science.gov (United States)

    ... and NutritionHealth Insurance: Understanding What It CoversHigh Homocysteine Level: How It Affects Your Blood VesselsUnderstanding Your Medical ... Health Resources Healthcare Management Monitoring Your Blood Sugar Level Monitoring Your Blood Sugar Level Share Print What ...

  3. INSTALLATION OF A POST-ACCIDENT CONFINEMENT HIGH-LEVEL RADIATION MONITORING SYSTEM IN THE KOLA NUCLEAR POWER STATION (UNIT 2) IN RUSSIA

    Energy Technology Data Exchange (ETDEWEB)

    GREENE,G.A.; GUPPY,J.G.

    1998-09-01

    This is the final report on the INSP project entitled, ``Post-Accident Confinement High-Level Radiation Monitoring System'' conducted by BNL under the authorization of Project Work Plan WBS 1.2.2.6 (Attachment 1). This project was initiated in February 1993 to assist the Russians in reducing risks associated with the continued operation of older Soviet-designed nuclear power plants, specifically the Kola VVER-440/230 Unit 2, through improved accident detection capability, specifically by the installation of a dual train high-level radiation detection system in the confinement of Unit 2 of the Kola NPP. The major technical objective of this project was to provide, install and make operational the necessary hardware inside the confinement of the Kola NPP Unit 2 to provide early and reliable warning of the release of radionuclides from the reactor into the confinement air space as an indication of the occurrence of a severe accident at the plant. In addition, it was intended to provide hands-on experience and training to the Russian plant workers in the installation, operation, calibration and maintenance of the equipment in order that they may use the equipment without continued US assistance as an effective measure to improve reactor safety at the plant.

  4. INSTALLATION OF A POST-ACCIDENT CONFINEMENT HIGH-LEVEL RADIATION MONITORING SYSTEM IN THE KOLA NUCLEAR POWER STATION (UNIT 2) IN RUSSIA

    International Nuclear Information System (INIS)

    GREENE, G.A.; GUPPY, J.G.

    1998-01-01

    This is the final report on the INSP project entitled, ''Post-Accident Confinement High-Level Radiation Monitoring System'' conducted by BNL under the authorization of Project Work Plan WBS 1.2.2.6 (Attachment 1). This project was initiated in February 1993 to assist the Russians in reducing risks associated with the continued operation of older Soviet-designed nuclear power plants, specifically the Kola VVER-440/230 Unit 2, through improved accident detection capability, specifically by the installation of a dual train high-level radiation detection system in the confinement of Unit 2 of the Kola NPP. The major technical objective of this project was to provide, install and make operational the necessary hardware inside the confinement of the Kola NPP Unit 2 to provide early and reliable warning of the release of radionuclides from the reactor into the confinement air space as an indication of the occurrence of a severe accident at the plant. In addition, it was intended to provide hands-on experience and training to the Russian plant workers in the installation, operation, calibration and maintenance of the equipment in order that they may use the equipment without continued US assistance as an effective measure to improve reactor safety at the plant

  5. Slope Monitoring using Total Station: What are the Challenges and ...

    African Journals Online (AJOL)

    ... survey perspective on the typical problems that can be expected during slope monitoring using total station (also known as prism monitoring) and second, to suggest ways of mitigating such problems. The aim is to create awareness of the implications of incorrect use or negligence during slope monitoring surveys utilising ...

  6. Emergency protection and nuclear power station remote monitoring

    International Nuclear Information System (INIS)

    Nowak, K.; Wolf, H.

    1986-01-01

    The States of the Federal Republic of Germany are planning emergency protection measures for the environment of nuclear power stations based on their statutory duty of care. In this connection the paper explains to what extent remote monitoring of nuclear power stations practised by the Federal Supervisory Authorities may support the design and implementation of emergency protection measures. (orig.) [de

  7. Establishing a mobile automatic monitoring station for emergency response

    International Nuclear Information System (INIS)

    Fang, Hsin-Fa

    2008-01-01

    Full text: A radiological/nuclear emergency event may cause environmental contamination. The emergency response works always need to plan an environmental survey programme incorporating the assessment results to see what is happening. The places where are assessed to have the highest radioactive contamination/radiation dose will catch more concern and need continuous monitoring. It will cause unnecessary dangers and dose to command that personnel conduct surveying in such places when the radiological/nuclear accident become more severe. A mobile automatic monitoring station has been established for emergency response by INER (Institute of Nuclear Energy Research) to solve the problem practically. The monitoring station involves a HPIC to monitor radiation dose, an anemometer to monitor wind speed and direction, a GPS to get position data, a GPRS/3G communication module to send monitoring and positioning data to the monitoring centre where can show the monitoring result directly on a map shown on the computer. These instruments are integrated in a trailer easy to be towed to the place need to be monitored. The electric power of the station is supplied by s a solar power energy system. It can supply the station working at least 10 days without extra electric power supply designed based on the expected time length of a nuclear power plant event. The HPIC is very sensitive and stable that can discriminate a 10 nSv/hr increasing of dose rate with the monitoring time period every ten seconds. Where the radiological dispersion device events happened is not predictable, it is difficult to get suitable wind monitoring data to assess the result of radiological dispersion device events. The anemometer added on the station can provide the real time wind monitoring data to help assessment works. (author)

  8. Trends of chemical monitoring in power stations

    International Nuclear Information System (INIS)

    Winkler, R.; Venz, H.

    1983-01-01

    Frequently, the state-of-the-art of chemical monitoring in power plants is still determined by conservative methods. A thorough rationalization requires not only modern analytical procedures, but also the consideration of chemically affected processes in complex process analyses and the combination of automatic analyzers with available process computers. Using some examples, ways of reducing monitoring efforts without impairing safety and economy of nuclear power plant operation are pointed out. (author)

  9. Slope Monitoring using Total Station: What are the Challenges and ...

    African Journals Online (AJOL)

    Afeni

    implications of incorrect use or negligence during slope monitoring surveys ... Data collection, processing and the presentation of results in a concise format ..... There are several software packages on the market for total station error propagation, ..... Thomas, H.G., 2011, Slope stability prism monitoring: A guide for practising ...

  10. Low-cost automatic station for compost temperature monitoring

    Directory of Open Access Journals (Sweden)

    Marcelo D. L. Jordão

    Full Text Available ABSTRACT Temperature monitoring is an important procedure to control the composting process. Due to cost limitation, temperature monitoring is manual and with daily sampling resolution. The objective of this study was to develop an automatic station with US$ 150 dollars, able to monitor air temperature at two different points in a compost pile, with a 5-min time resolution. In the calibration test, the sensors showed an estimated uncertainty from ± 1 to ± 1.9 ºC. In the field validation test, the station guaranteed secure autonomy for seven days and endured high humidity and extreme temperature (> 70 °C.

  11. Space Station Environmental Health System water quality monitoring

    Science.gov (United States)

    Vincze, Johanna E.; Sauer, Richard L.

    1990-01-01

    One of the unique aspects of the Space Station is that it will be a totally encapsulated environment and the air and water supplies will be reclaimed for reuse. The Environmental Health System, a subsystem of CHeCS (Crew Health Care System), must monitor the air and water on board the Space Station Freedom to verify that the quality is adequate for crew safety. Specifically, the Water Quality Subsystem will analyze the potable and hygiene water supplies regularly for organic, inorganic, particulate, and microbial contamination. The equipment selected to perform these analyses will be commercially available instruments which will be converted for use on board the Space Station Freedom. Therefore, the commercial hardware will be analyzed to identify the gravity dependent functions and modified to eliminate them. The selection, analysis, and conversion of the off-the-shelf equipment for monitoring the Space Station reclaimed water creates a challenging project for the Water Quality engineers and scientists.

  12. New Seismic Monitoring Station at Mohawk Ridge, Valles Caldera

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, Peter Morse [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-09-20

    Two new broadband digital seismic stations were installed in the Valles Caldera in 2011 and 2012. The first is located on the summit of Cerros del Abrigo (station code CDAB) and the second is located on the flanks of San Antonio Mountain (station code SAMT). Seismic monitoring stations in the caldera serve multiple purposes. These stations augment and expand the current coverage of the Los Alamos Seismic Network (LASN), which is operated to support seismic and volcanic hazards studies for LANL and northern New Mexico (Figure 1). They also provide unique continuous seismic data within the caldera that can be used for scientific studies of the caldera’s substructure and detection of very small seismic signals that may indicate changes in the current and evolving state of remnant magma that is known to exist beneath the caldera. Since the installation of CDAB and SAMT, several very small earthquakes have already been detected near San Antonio Mountain just west of SAMT (Figure 2). These are the first events to be seen in that area. Caldera stations also improve the detection and epicenter determination quality for larger local earthquakes on the Pajarito Fault System east of the Preserve and the Nacimiento Uplift to the west. These larger earthquakes are a concern to LANL Seismic Hazards assessments and seismic monitoring of the Los Alamos region, including the VCNP, is a DOE requirement. Currently the next closest seismic stations to the caldera are on Pipeline Road (PPR) just west of Los Alamos, and Peralta Ridge (PER) south of the caldera. There is no station coverage near the resurgent dome, Redondo Peak, in the center of the caldera. Filling this “hole” is the highest priority for the next new LASN station. We propose to install this station in 2018 on Mohawk Ridge just east of Redondito, in the same area already occupied by other scientific installations, such as the MCON flux tower operated by UNM.

  13. R2 Water Quality Portal Monitoring Stations

    Science.gov (United States)

    The Water Quality Data Portal (WQP) provides an easy way to access data stored in various large water quality databases. The WQP provides various input parameters on the form including location, site, sampling, and date parameters to filter and customize the returned results. The The Water Quality Portal (WQP) is a cooperative service sponsored by the United States Geological Survey (USGS), the Environmental Protection Agency (EPA) and the National Water Quality Monitoring Council (NWQMC) that integrates publicly available water quality data from the USGS National Water Information System (NWIS) the EPA STOrage and RETrieval (STORET) Data Warehouse, and the USDA ARS Sustaining The Earth??s Watersheds - Agricultural Research Database System (STEWARDS).

  14. Atmosphere and water quality monitoring on Space Station Freedom

    Science.gov (United States)

    Niu, William

    1990-01-01

    In Space Station Freedom air and water will be supplied in closed loop systems. The monitoring of air and water qualities will ensure the crew health for the long mission duration. The Atmosphere Composition Monitor consists of the following major instruments: (1) a single focusing mass spectrometer to monitor major air constituents and control the oxygen/nitrogen addition for the Space Station; (2) a gas chromatograph/mass spectrometer to detect trace contaminants; (3) a non-dispersive infrared spectrometer to determine carbon monoxide concentration; and (4) a laser particle counter for measuring particulates in the air. An overview of the design and development concepts for the air and water quality monitors is presented.

  15. A report on upgraded seismic monitoring stations in Myanmar: Station performance and site response

    Science.gov (United States)

    Thiam, Hrin Nei; Min Htwe, Yin Myo; Kyaw, Tun Lin; Tun, Pa Pa; Min, Zaw; Htwe, Sun Hninn; Aung, Tin Myo; Lin, Kyaw Kyaw; Aung, Myat Min; De Cristofaro, Jason; Franke, Mathias; Radman, Stefan; Lepiten, Elouie; Wolin, Emily; Hough, Susan E.

    2017-01-01

    Myanmar is in a tectonically complex region between the eastern edge of the Himalayan collision zone and the northern end of the Sunda megathrust. Until recently, earthquake monitoring and research efforts have been hampered by a lack of modern instrumentation and communication infrastructure. In January 2016, a major upgrade of the Myanmar National Seismic Network (MNSN; network code MM) was undertaken to improve earthquake monitoring capability. We installed five permanent broadband and strong‐motion seismic stations and real‐time data telemetry using newly improved cellular networks. Data are telemetered to the MNSN hub in Nay Pyi Taw and archived at the Incorporated Research Institutions for Seismology Data Management Center. We analyzed station noise characteristics and site response using noise and events recorded over the first six months of station operation. Background noise characteristics vary across the array, but indicate that the new stations are performing well. MM stations recorded more than 20 earthquakes of M≥4.5 within Myanmar and its immediate surroundings, including an M 6.8 earthquake located northwest of Mandalay on 13 April 2016 and the Mw 6.8 Chauk event on 24 August 2016. We use this new dataset to calculate horizontal‐to‐vertical spectral ratios, which provide a preliminary characterization of site response of the upgraded MM stations.

  16. Type of equipment in an air monitoring station

    International Nuclear Information System (INIS)

    Levy, F.

    1999-01-01

    This poster communication presents a general view of the station, the different materials used for the air and precipitations monitoring. The methods for gas measurements (tritium, krypton, iodine) are given. The collecting of dusts, dust and tritium mixed together, or rainwater and pluviometry are reviewed and the measurement of ambient radioactivity is made by beacon. (N.C.)

  17. An analysis of spatial representativeness of air temperature monitoring stations

    Science.gov (United States)

    Liu, Suhua; Su, Hongbo; Tian, Jing; Wang, Weizhen

    2018-05-01

    Surface air temperature is an essential variable for monitoring the atmosphere, and it is generally acquired at meteorological stations that can provide information about only a small area within an r m radius ( r-neighborhood) of the station, which is called the representable radius. In studies on a local scale, ground-based observations of surface air temperatures obtained from scattered stations are usually interpolated using a variety of methods without ascertaining their effectiveness. Thus, it is necessary to evaluate the spatial representativeness of ground-based observations of surface air temperature before conducting studies on a local scale. The present study used remote sensing data to estimate the spatial distribution of surface air temperature using the advection-energy balance for air temperature (ADEBAT) model. Two target stations in the study area were selected to conduct an analysis of spatial representativeness. The results showed that one station (AWS 7) had a representable radius of about 400 m with a possible error of less than 1 K, while the other station (AWS 16) had the radius of about 250 m. The representable radius was large when the heterogeneity of land cover around the station was small.

  18. Pilot Water Quality Monitoring Station in Dublin Bay : North Bank Station (NBMS), MATSIS Project Part I

    OpenAIRE

    O'Donnell, Garvan; Joyce, Eileen; Silke, Joe; O'Boyle, Shane; McGovern, Evin

    2008-01-01

    This report describes the pilot development of an autonomous monitoring station in Dublin Bay and validation of the system. It presents results from initial deployments. Sensors were deployed for testing, including an optical sensor for measuring nitrate and sensors for measurement of salinity, temperature, fluorescence and dissolved oxygen. Automated water samplers enabled periodic, remote triggered and event triggered sampling for nutrient and phytoplankton samples.

  19. The central monitoring station of Indian Environmental Radiation Monitoring Network (IERMON): the architecture and functions

    International Nuclear Information System (INIS)

    Garg, Saurabh; Ratheesh, M.P.; Mukundan, T.; Patel, M.D.; Nair, C.K.G.; Puranik, V.D.

    2010-01-01

    The Indian Environmental Radiation Monitoring Network (IERMON) is being established across the country by the Bhabha Atomic Research Centre, Mumbai. The network consists of stations with automated systems for environmental radiation monitoring with online data communication facility. Currently about 100 stations are operational and additional 500 stations are expected to be installed by March, 2012. The network is established with different objectives, the main objective being the detection and reporting of any nuclear emergency anywhere in the country. The central monitoring station of the network is established in Mumbai. This paper describes the architecture and functions of IERMON Central Station. The Central Station consists of server room for online data collection from remote stations and maintenance of databases for various applications; central monitoring room for user interaction with database and IERMON website maintenance and development room for the development of new applications. The functions of IERMON Central Station include detection and reporting of nuclear emergency, maintenance of remote stations, enhancement of public awareness on environmental radiation through public display systems and website, etc. The details on system layout and data protocols can be found in the paper. (author)

  20. Establishment of a Background Environmental Monitoring Station for the PNNL Campus

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, Brad G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Snyder, Sandra F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Barnett, J. Matthew [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bisping, Lynn E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rishel, Jeremy P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-12-01

    The environmental surveillance of background levels of radionuclides and, in particular, the siting of a background environmental surveillance (monitoring) station are examined. Many published works identify and stress the need for background monitoring; however, little definitive and comprehensive information for siting a station exists. A definition of an ideal background monitoring location and the generic criteria recommended for use in establishing such a background monitoring location are proposed. There are seven primary (mandatory) criteria described with two additional, optional criteria. The criteria are applied to the Richland, Washington (WA), Pacific Northwest National Laboratory (PNNL) Campus, which currently uses background monitoring data from the nearby Hanford Site. Eleven potential background monitoring sites were identified, with one location in Benton City, WA found to meet all of the mandatory and optional criteria. It is expected that the new sampler will be installed and operating by the end of June, 2015.

  1. Spectral characteristics of seismic noise using data of Kazakhstan monitoring stations

    International Nuclear Information System (INIS)

    Mikhajlova, N.N.; Komarov, I.I.

    2006-01-01

    Spectral specifications of seismic noise research for PS23-Makanchi, Karatau, Akbulak, AS057-Borovoye and new three-component station AS059-Aktyubinsk was done. Spectral noise density models were obtained for day and night time and spectral density values variation. Noise close to low-level universal noise model is peculiar for all stations, which provides their high efficiency while seismic monitoring. Noise parameters dependence on seismic receivers installation conditions was investigated separately. Based on three stations (Makanchi, Borovoye, and Aktyubinsk), spectral density change features are shown after borehole equipment installation. (author)

  2. The influence of subway station design on noise levels.

    Science.gov (United States)

    Shah, Ravi R; Suen, Jonathan J; Cellum, Ilana P; Spitzer, Jaclyn B; Lalwani, Anil K

    2017-05-01

    To investigate the impact of subway station design on platform noise levels. Observational. Continuous A-weighted decibel (dBA) sound levels were recorded in 20 New York City subway stations, where trains entered on either a straight track or curved track in 10 stations each. Equivalent continuous noise levels (L eq ) at various locations on the boarding platform (inbound end, midplatform, and outbound end) during train entry and exit were compared between the straight and curved stations in broadband as well as narrow one-third octave bands. Overall, curved stations trended louder than straight stations, although the difference in broadband L eq did not reach statistical significance (curve, 83.4 dBA; straight, 82.6 dBA; P = .054). Noise levels were significantly louder at the inbound end of the platform during train entry (inbound, 89.7 dBA; mid, 85.5 dBA; outbound, 78.7 dBA; P < .001) and at the outbound end during train exit (inbound, 79.7 dBA; mid, 85.3 dBA; outbound, 89.1 dBA; P < .001). Narrow band analysis showed that curved stations were significantly louder than straight stations at 100 Hz and high frequencies from 8 to 20 kHz. Peak impact levels ranged from 104 to 121 dBA. Curved stations have a different noise profile compared to straight stations and are significantly louder than straight stations at high frequencies. Designing stations with straight tracks within the platform can help reduce commuter noise exposure. NA Laryngoscope, 127:1169-1174, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  3. Atmosphere composition monitor for space station and advanced missions application

    International Nuclear Information System (INIS)

    Wynveen, R.A.; Powell, F.T.

    1987-01-01

    Long-term human occupation of extraterrestrial locations may soon become a reality. The National Aeronautics and Space Administration (NASA) has recently completed the definition and preliminary design of the low earth orbit (LEO) space station. They are now currently moving into the detailed design and fabrication phase of this space station and are also beginning to analyze the requirements of several future missions that have been identified. These missions include, for example, Lunar and Mars sorties, outposts, bases, and settlements. A requirement of both the LEO space station and future missions are environmental control and life support systems (ECLSS), which provide a comfortable environment for humans to live and work. The ECLSS consists of several major systems, including atmosphere revitalization system (ARS), atmosphere pressure and composition control system, temperature and humidity control system, water reclamation system, and waste management system. Each of these major systems is broken down into subsystems, assemblies, units, and instruments. Many requirements and design drivers are different for the ECLSS of the LEO space station and the identified advanced missions (e.g., longer mission duration). This paper discusses one of the ARS assemblies, the atmosphere composition monitor assembly (ACMA), being developed for the LEO space station and addresses differences that will exist for the ACMA of future missions

  4. Real-time trend monitoring of gas compressor stations

    Energy Technology Data Exchange (ETDEWEB)

    Van Hardeveld, T. (Nova, an Alberta Corp., AB (Canada))

    1991-02-01

    The authors' company has developed a machinery health monitoring system (MHealth) for short-term and long-term historical trending and analysis of data from its 40 gas compressor stations. The author discusses the benefits of real-time trending in troubleshooting operations, in preventative maintenance scheduling and cites specific applications in the startup operations of several new gas compressor/centrifugal compressor units.

  5. Mobile and modular. BGR develops seismological monitoring stations for universal applications

    International Nuclear Information System (INIS)

    Hinz, Erwin; Hanneken, Mark

    2016-01-01

    BGR seismologists often set up monitoring stations for testing purposes. The engineers from the Central Seismological Observatory have now developed a new type of mobile monitoring station which can be remotely controlled.

  6. Level of Radiofrequency (RF) Radiations from GSM Base Stations ...

    African Journals Online (AJOL)

    Levels of radiofrequency radiations around two global systems for mobile communication (GSM) base stations located in the vicinity of a residential quarter and workplace complex were measured. The effects of the radiofrequency radiations on albino mice placed in exposure cages and located around the base stations ...

  7. Energy Management for Automatic Monitoring Stations in Arctic Regions

    Science.gov (United States)

    Pimentel, Demian

    Automatic weather monitoring stations deployed in arctic regions are usually installed in hard to reach locations. Most of the time they run unsupervised and they face severe environmental conditions: very low temperatures, ice riming, etc. It is usual practice to use a local energy source to power the equipment. There are three main ways to achieve this: (1) a generator whose fuel has to be transported to the location at regular intervals (2) a battery and (3) an energy harvesting generator that exploits a local energy source. Hybrid systems are very common. Polar nights and long winters are typical of arctic regions. Solar radiation reaching the ground during this season is very low or non-existent, depending on the geographical location. Therefore, solar power generation is not very effective. One straightforward, but expensive and inefficient solution is the use of a large bank of batteries that is recharged during sunny months and discharged during the winter. The main purpose of the monitoring stations is to collect meteorological data at regular intervals; interruptions due to a lack of electrical energy can be prevented with the use of an energy management subsystem. Keeping a balance between incoming and outgoing energy flows, while assuring the continuous operation of the station, is the delicate task of energy management strategies. This doctoral thesis explores alternate power generation solutions and intelligent energy management techniques for equipment deployed in the arctic. For instance, harvesting energy from the wind to complement solar generation is studied. Nevertheless, harvested energy is a scarce resource and needs to be used efficiently. Genetic algorithms, fuzzy logic, and common sense are used to efficiently manage energy flows within a simulated arctic weather station.

  8. Monitoring and optimization of energy consumption of base transceiver stations

    International Nuclear Information System (INIS)

    Spagnuolo, Antonio; Petraglia, Antonio; Vetromile, Carmela; Formosi, Roberto; Lubritto, Carmine

    2015-01-01

    The growth and development of the mobile phone network has led to an increased demand for energy by the telecommunications sector, with a noticeable impact on the environment. Monitoring of energy consumption is a great tool for understanding how to better manage this consumption and find the best strategy to adopt in order to maximize reduction of unnecessary usage of electricity. This paper reports on a monitoring campaign performed on six BSs (Base Transceiver Stations) located central Italy, with different technology, typology and technical characteristics. The study focuses on monitoring energy consumption and environmental parameters (temperature, noise, and global radiation), linking energy consumption with the load of telephone traffic and with the air conditioning functions used to cool the transmission equipment. Moreover, using experimental data collected, it is shown, with a Monte Carlo simulation based on power saving features, how the BS monitored could save energy. - Highlights: • Energy consumption and environmental parameters of a base transceiver system have been monitored. • Energy consumption is related to the air conditioning functions and to the load of telephone traffic. • Energy saving can be obtained by careful choice of cooling parameters and by turn off BS transceivers. • Energy saving parameters can be estimated by a simulation Monte Carlo method

  9. Radiation level survey of a mobile phone base station

    International Nuclear Information System (INIS)

    Campos, M.C.; Schaffer, S.R.

    2006-01-01

    Electromagnetic field (E.M.F.) evaluations were carried out in the surroundings of a roof-top mobile-phone radio-base station (R.B.S.). Four of its sector-panel antennas are installed on two parallel vertical masts, each supporting two panels in a vertical collinear-array. The geometry is such that the vertical plane containing both masts is about 10 meters distant and parallel to the backside of an educational institution. This proximity provoked great anxiety among the local community members regarding potential health hazards.1. Introduction: To keep up with the expansion of the mobile-phone services, the number of Radio-Base Stations (R.B.S.) installations is increasing tremendously in Brazil. Efficient control and radiation monitoring to assess R.B.S. compliance to existing regulations are still lacking and particularly in big cities, clearly non - compliant R.B.S. can be seen which represent potentially hazardous E.M.F. sources to the nearby population. This first survey of an irregular R.B.S. revealed significant E-field strengths outside, as well as inside a classroom of an educational building where an usually prolonged stay is necessary. These results confirm that this problem deserves further attention, moreover, if one considers that public and occupational exposure limits set by I.C.N.I.R.P. (also adopted in Brazil) are exclusively based on the immediate thermal effects of acute exposure, disregarding any potential health risk from prolonged exposure to lower level radiation. Research activities focusing on quantitative aspects of electromagnetic radiation from R.B.S., as well as on biological and adverse health effects are still at a very incipient level, urging for immediate actions to improve this scenario in our country. 2. Material, methods and results Measurements were carried out with a broadband field strength monitor, E.M.R.-300 (W and G) coupled to an isotropic E-field probe (100 khz to 3 GHz). Preliminary measurements helped locating

  10. International remote monitoring project Argentina Nuclear Power Station Spent Fuel Transfer Remote Monitoring System

    International Nuclear Information System (INIS)

    Schneider, S.; Lucero, R.; Glidewell, D.

    1997-01-01

    The Autoridad Regulataria Nuclear (ARN) and the United States Department of Energy (DOE) are cooperating on the development of a Remote Monitoring System for nuclear nonproliferation efforts. A Remote Monitoring System for spent fuel transfer will be installed at the Argentina Nuclear Power Station in Embalse, Argentina. The system has been designed by Sandia National Laboratories (SNL), with Los Alamos National Laboratory (LANL) and Oak Ridge National Laboratory (ORNL) providing gamma and neutron sensors. This project will test and evaluate the fundamental design and implementation of the Remote Monitoring System in its application to regional and international safeguards efficiency. This paper provides a description of the monitoring system and its functions. The Remote Monitoring System consists of gamma and neutron radiation sensors, RF systems, and video systems integrated into a coherent functioning whole. All sensor data communicate over an Echelon LonWorks Network to a single data logger. The Neumann DCM 14 video module is integrated into the Remote Monitoring System. All sensor and image data are stored on a Data Acquisition System (DAS) and archived and reviewed on a Data and Image Review Station (DIRS). Conventional phone lines are used as the telecommunications link to transmit on-site collected data and images to remote locations. The data and images are authenticated before transmission. Data review stations will be installed at ARN in Buenos Aires, Argentina, ABACC in Rio De Janeiro, IAEA Headquarters in Vienna, and Sandia National Laboratories in Albuquerque, New Mexico. 2 refs., 2 figs

  11. 40 CFR 52.1080 - Photochemical Assessment Monitoring Stations (PAMS) Program.

    Science.gov (United States)

    2010-07-01

    ... Stations (PAMS) Program. 52.1080 Section 52.1080 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 52.1080 Photochemical Assessment Monitoring Stations (PAMS) Program. On March 24, 1994 Maryland's... Assessment Monitoring Stations (PAMS) Program as a state implementation plan (SIP) revision, as required by...

  12. 40 CFR 52.2426 - Photochemical Assessment Monitoring Stations (PAMS) Program.

    Science.gov (United States)

    2010-07-01

    ... Stations (PAMS) Program. 52.2426 Section 52.2426 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... § 52.2426 Photochemical Assessment Monitoring Stations (PAMS) Program. On November 23, 1994 Virginia's... Photochemical Assessment Monitoring Stations (PAMS) Program as a state implementation plan (SIP) revision, as...

  13. Natural radiation external exposures levels in Chilean Sub-Antarctic and country stations

    International Nuclear Information System (INIS)

    Stuardo, E.

    1988-01-01

    Since 1983 gamma exposures levels, at 1,5 m above the soil are being investigated using TLD detectors. A network of 12 stations have been established from ARICA (18 deg 20' S latitude) in Northern Chile to YELCHO (64 deg 52' S latitude) in Antartic territory. One year monitoring period was used at Antartic stations and a four months period in the country. The main subject of this study is to assess the average background radiation levels along the territory which is relevant to get a reference level and specially an estimate of the average natural radiation contribution to the population dose in Southern Chile

  14. Exposure level from selected base station tower around Kuala Nerus

    African Journals Online (AJOL)

    Health risk due to RF radiation exposure from base station tower (BST) has been debated for years leading to public concerns. Thus, this preliminary study aims to measure, evaluate and analyze the exposure level on three selected BST around Kuala Nerus. The measurement of exposure level in terms of voltage ...

  15. Reactor Emergency Action Level Monitor

    International Nuclear Information System (INIS)

    Touchton, R.A.

    1987-01-01

    The Reactor Emergency Action Level Monitor (REALM) Expert System is designed to provide assistance in the identification of a nuclear power plant emergency situation and the determination of its severity. REALM has been developed to operate in a real-time processing environment. REALM embodies a hybrid architecture utilizing both rule-based reasoning and object-oriented programming techniques borrowed from the Artificial Intelligence discipline of Computer Sciences. The rulebase consists of event-based rules and symptom-based rules. The symptom-based rules go beyond the current EAL structure to address the more problematic scenarios and entail a more symbolic representation of the plant information. The results to date have been encouraging that expert system technology can provide improved emergency decision-making capability in nuclear power plants

  16. Proton irradiation experiment for x-ray charge-coupled devices of the monitor of all-sky x-ray image mission onboard the international space station. 2. Degradation of dark current and identification of electron trap level

    CERN Document Server

    Miyata, E; Kamiyama, D

    2003-01-01

    We have investigated the radiation damage effects on a charge-coupled device (CCD) to be used for the Japanese X-ray mission, the monitor of all-sky X-ray image (MAXI), onboard the international space station (ISS). A temperature dependence of the dark current as a function of incremental dose is studied. We found that the protons having energy of >292 keV seriously increased the dark current of the devices. In order to improve the radiation tolerance of the devices, we have developed various device architectures to minimize the radiation damage in orbit. Among them, nitride oxide enables us to reduce the dark current significantly and therefore we adopted nitride oxide for the flight devices. We also compared the dark current of a device in operation and that out of operation during the proton irradiation. The dark current of the device in operation became twofold that out of operation, and we thus determined that devices would be turned off during the passage of the radiation belt. The temperature dependenc...

  17. Cluster processing business level monitor

    International Nuclear Information System (INIS)

    Muniz, Francisco J.

    2017-01-01

    This article describes a Cluster Processing Monitor. Several applications with this functionality can be freely found doing a search in the Google machine. However, those applications may offer more features that are needed on the Processing Monitor being proposed. Therefore, making the monitor output evaluation difficult to be understood by the user, at-a-glance. In addition, such monitors may add unnecessary processing cost to the Cluster. For these reasons, a completely new Cluster Processing Monitor module was designed and implemented. In the CDTN, Clusters are broadly used, mainly, in deterministic methods (CFD) and non-deterministic methods (Monte Carlo). (author)

  18. Cluster processing business level monitor

    Energy Technology Data Exchange (ETDEWEB)

    Muniz, Francisco J., E-mail: muniz@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    This article describes a Cluster Processing Monitor. Several applications with this functionality can be freely found doing a search in the Google machine. However, those applications may offer more features that are needed on the Processing Monitor being proposed. Therefore, making the monitor output evaluation difficult to be understood by the user, at-a-glance. In addition, such monitors may add unnecessary processing cost to the Cluster. For these reasons, a completely new Cluster Processing Monitor module was designed and implemented. In the CDTN, Clusters are broadly used, mainly, in deterministic methods (CFD) and non-deterministic methods (Monte Carlo). (author)

  19. Monitoring the Dead Sea Region by Multi-Parameter Stations

    Science.gov (United States)

    Mohsen, A.; Weber, M. H.; Kottmeier, C.; Asch, G.

    2015-12-01

    The Dead Sea Region is an exceptional ecosystem whose seismic activity has influenced all facets of the development, from ground water availability to human evolution. Israelis, Palestinians and Jordanians living in the Dead Sea region are exposed to severe earthquake hazard. Repeatedly large earthquakes (e.g. 1927, magnitude 6.0; (Ambraseys, 2009)) shook the whole Dead Sea region proving that earthquake hazard knows no borders and damaging seismic events can strike anytime. Combined with the high vulnerability of cities in the region and with the enormous concentration of historical values this natural hazard results in an extreme earthquake risk. Thus, an integration of earthquake parameters at all scales (size and time) and their combination with data of infrastructure are needed with the specific aim of providing a state-of-the-art seismic hazard assessment for the Dead Sea region as well as a first quantitative estimate of vulnerability and risk. A strong motivation for our research is the lack of reliable multi-parameter ground-based geophysical information on earthquakes in the Dead Sea region. The proposed set up of a number of observatories with on-line data access will enable to derive the present-day seismicity and deformation pattern in the Dead Sea region. The first multi-parameter stations were installed in Jordan, Israel and Palestine for long-time monitoring. All partners will jointly use these locations. All stations will have an open data policy, with the Deutsches GeoForschungsZentrum (GFZ, Potsdam, Germany) providing the hard and software for real-time data transmission via satellite to Germany, where all partners can access the data via standard data protocols.

  20. Design/installation and structural integrity assessment under the Federal Facility Agreement for Bethel Valley Low-Level Waste Collection and Transfer System upgrade for Building 2026 (High Radiation Level Analytical Laboratory) and Building 2099 (Monitoring and Control Station) at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    1994-10-01

    This document presents a Design/Installation and Structural Integrity Assessment for a replacement tank system for portions of the Bethel Valley Low Level Waste (LLW) System, located at the Oak Ridge Reservation, Oak Ridge, Tennessee. This issue of the assessment covers the design aspects of the replacement tank system, and certifies that the design has sufficient structural integrity and is acceptable for the storing or treating of hazardous and/or radioactive substances. The present issue identifies specific activities that must be completed during the fabrication, installation, and testing of the replacement tank system in order to provide assurance that the final installation complies with governing requirements. Portions of the LLW system are several decades old, or older, and do not comply with current environmental protection regulations. Several subsystems of the LLW system have been designated to receive a state-of-the-art replacement and refurbishment. One such subsystem serves Building 2026, the High Radiation Level Analytical Laboratory. This assessment focuses on the scope of work for the Building 2026 replacement LLW Collection and Transfer System, including the provision of a new Monitoring and Control Station (Building 2099) to receive, store, and treat (adjust pH) low level radioactive waste

  1. Analysis of time series exposure rates obtained at a monitoring station around nuclear power stations

    International Nuclear Information System (INIS)

    Urabe, I.; Ogawa, Y.; Kimura, Y.; Honda, Y.; Nakashima, Y.; Yoshimoto, T.; Tsujimoto, T.

    1991-01-01

    From the investigation on the variation of AAD rates monitored in the natural environment around nuclear power station, it may be concluded; (1) Differences between monthly averaged air absorbed dose rates (AAD rates) given by all data obtained and those obtained in fine weather become larger in winter (from Dec. to Feb.) (2) Cummulative frequency distributions of AAD rates are very different among four seasons. Remarkably high AAD rates are observed by heavy rains in summer and snow falls or rains in winter. (3) Though the hypothesis that the frequency distribution of AAD rates fit to the lognormal distribution can not be accepted by chi-square test, higher part of the frequency distribution of AAD rates agree approximately with the lognormal one. (4) Identification of AAD rates due to plume exposure may be possible by statistical analysis assuming lognormal distribution of AAD rates as well as the discrimination method based on the reference standard using mean values and standard deviations of the data obtained in fine weather. (author)

  2. International Remote Monitoring Project Embalse Nuclear Power Station, Argentina Embalse Remote Monitoring System

    International Nuclear Information System (INIS)

    Schneider, Sigfried L.; Glidewell, Donnie D.; Bonino, Anibal; Bosler, Gene; Mercer, David; Maxey, Curt; Vones, Jaromir; Martelle, Guy; Busse, James; Kadner, Steve; White, Mike; Rovere, Luis

    1999-01-01

    The Autoridad Regulatoria Nuclear of Argentina (ARN), the International Atomic Energy Agency (IAEA), ABACC, the US Department of Energy, and the US Support Program POTAS, cooperated in the development of a Remote Monitoring System for nuclear nonproliferation efforts. This system was installed at the Embalse Nuclear Power Station last year to evaluate the feasibility of using radiation sensors in monitoring the transfer of spent fuel from the spent fuel pond to dry storage. The key element in this process is to maintain continuity of knowledge throughout the entire transfer process. This project evaluated the fundamental design and implementation of the Remote Monitoring System in its application to regional and international safeguard efficiency. New technology has been developed to enhance the design of the system to include storage capability on board sensor platforms. This evaluation has led to design enhancements that will assure that no data loss will occur during loss of RF transmission of the sensors

  3. FLAME MONITORING IN POWER STATION BOILERS USING IMAGE PROCESSING

    Directory of Open Access Journals (Sweden)

    K. Sujatha

    2012-05-01

    Full Text Available Combustion quality in power station boilers plays an important role in minimizing the flue gas emissions. In the present work various intelligent schemes to infer the flue gas emissions by monitoring the flame colour at the furnace of the boiler are proposed here. Flame image monitoring involves capturing the flame video over a period of time with the measurement of various parameters like Carbon dioxide (CO2, excess oxygen (O2, Nitrogen dioxide (NOx, Sulphur dioxide (SOx and Carbon monoxide (CO emissions plus the flame temperature at the core of the fire ball, air/fuel ratio and the combustion quality. Higher the quality of combustion less will be the flue gases at the exhaust. The flame video was captured using an infrared camera. The flame video is then split up into the frames for further analysis. The video splitter is used for progressive extraction of the flame images from the video. The images of the flame are then pre-processed to reduce noise. The conventional classification and clustering techniques include the Euclidean distance classifier (L2 norm classifier. The intelligent classifier includes the Radial Basis Function Network (RBF, Back Propagation Algorithm (BPA and parallel architecture with RBF and BPA (PRBFBPA. The results of the validation are supported with the above mentioned performance measures whose values are in the optimal range. The values of the temperatures, combustion quality, SOx, NOx, CO, CO2 concentrations, air and fuel supplied corresponding to the images were obtained thereby indicating the necessary control action taken to increase or decrease the air supply so as to ensure complete combustion. In this work, by continuously monitoring the flame images, combustion quality was inferred (complete/partial/incomplete combustion and the air/fuel ratio can be automatically varied. Moreover in the existing set-up, measurements like NOx, CO and CO2 are inferred from the samples that are collected periodically or by

  4. Environmental levels of microwave radiation around a satellite earth station

    International Nuclear Information System (INIS)

    Joyner, K.H.; Bangay, M.J.

    1986-01-01

    This paper discusses the background to claims of possible adverse health effects arising from exposure to environmental levels of microwave radiation around satellite earth stations. Results of a recent survey of the environmental levels of microwave radiation around two 32 metre diameter satellite communications antennas owned and operated by the Overseas Telecommunications Commission (OTC) of Australia are presented. From the measurements obtained in this survey it can be concluded that the environmental levels of microwave radiation around the OTC and similar satellite facilities do not pose a health risk to persons in the vicinity

  5. [Level of microwave radiation from mobile phone base stations built in residential districts].

    Science.gov (United States)

    Hu, Ji; Lu, Yiyang; Zhang, Huacheng; Xie, Hebing; Yang, Xinwen

    2009-11-01

    To investigate the condition of microwave radiation pollution from mobile phone base station built in populated area. Random selected 18 residential districts where had base station and 10 residential districts where had no base stations. A TES-92 electromagnetic radiation monitor were used to measure the intensity of microwave radiation in external and internal living environment. The intensities of microwave radiation in the exposure residential districts were more higher than those of the control residential districts (p station, it would gradually weaken with the increase of the distance. The level of microwave radiation in antenna main lobe region is not certainly more higher than the side lobe direction, and the side lobe direction also is not more lower. At the same district, where there were two base stations, the electromagnetic field nestification would take place in someplace. The intensities of microwave radiation outside the exposure windows in the resident room not only changed with distance but also with the height of the floor. The intensities of microwave radiation inside the aluminum alloys security net were more lower than those of outside the aluminum alloys security net (p 0.05). Although all the measure dates on the ground around the base station could be below the primary standard in "environment electromagnetic wave hygienic standard" (GB9175-88), there were still a minorities of windows which exposed to the base station were higher, and the outside or inside of a few window was even higher beyond the primary safe level defined standard. The aluminum alloys security net can partly shield the microwave radiation from the mobile phone base station.

  6. Existing Noise Level at Railway Stations in Malaysia

    Directory of Open Access Journals (Sweden)

    Shahidan Shahiron

    2017-01-01

    Full Text Available Railway transportation known as one of the most environmental friendly transportation mode. However, the significance problems of railway transportation are noise pollution and negatively impact the wellbeing of the whole community. Unfortunately, there has been lack of public awareness about the noise level produce by the railway transportation in Malaysia. This study investigates the noise level produced by railway transportation in Malaysia specifically by Keretapi Tanah Melayu Berhad (KTMB. Methods of collecting existing noise level at railway stations in Malaysia are briefly discussed in this study. The finding indicates that the noise level produced by the railway transportation in Malaysia which is by KTMB is considered as dangerous to human being and also exceed the noise limit that has been assigned by Department of Environment Ministry of Natural Resources and Environment of Malaysia. A better noise barrier and improved material should be developed to mitigate the existing noise level produced by railway transportations in Malaysia.

  7. Seabrook Station Level 2 PRA Update to Include Accident Management

    International Nuclear Information System (INIS)

    Lutz, Robert; Lucci, Melissa; Kiper, Kenneth; Henry, Robert

    2006-01-01

    A ground-breaking study was recently completed as part of the Seabrook Level 2 PRA update. This study updates the post-core damage phenomena to be consistent with the most recent information and includes accident management activities that should be modeled in the Level 2 PRA. Overall, the result is a Level 2 PRA that fully meets the requirements of the ASME PRA Standard with respect to modeling accident management in the LERF assessment and NRC requirements in Regulatory Guide 1.174 for considering late containment failures. This technical paper deals only with the incorporation of operator actions into the Level 2 PRA based on a comprehensive study of the Seabrook Station accident response procedures and guidance. The paper describes the process used to identify the key operator actions that can influence the Level 2 PRA results and the development of success criteria for these key operator actions. This addresses a key requirement of the ASME PRA Standard for considering SAMG. An important benefit of this assessment was the identification of Seabrook specific accident management insights that can be fed back into the Seabrook Station accident management procedures and guidance or the training provided to plant personnel for these procedures and guidance. (authors)

  8. A portable meteorological station plus nuclear radiation monitoring system using a basic-8052 micro-controller

    International Nuclear Information System (INIS)

    Al-Mohamad, A.; Aghabi, S.; Weiss, C.

    2002-01-01

    a portable meteorology station capable of measuring various atmospheric parameters (mainly ambient temperature, relative humidity, atmospheric pressure, wind speed and direction) was designed and built. The physical quantities were converted to electrical signals using suitable sensors. These signals were then processed and transferred to digital values to be stored in suitable memories. A nuclear radiation alarm system was also built, on the main board, to monitor the nuclear radiation releases levels. The system consists of three main parts: control board, data acquisition board and signals conditioning board. the overall system is controlled by a BASIC-8052 micro-controller. (authors)

  9. Supervision monitoring for radiation environment around Daya Bay and Lingao nuclear power stations

    International Nuclear Information System (INIS)

    Huang Naiming; Chen Zhidong; Song Haiqing; Deng Fei; Lin Qing; Huang Nairong; Zhou Ruidong; Mo Guanghua; Li Lingjuan; Liu Ying; Li Qiaoqin; Lai Liming; Zhou Xue

    2004-01-01

    This paper systematically introduces the supervision monitoring for radiation environment around the Guangdong Daya Bay and Ling Ao nuclear power station by the Guangdong Environmental Radiation Research and Monitoring Center. It includes the monitoring plan, methods, quality assurance, main results and conclusions. The results show that: (1) The gas discharge have not caused any detectable impacts to the terrestrial and atmospheric environment since their operation; (2) 110m Ag could only be detected in seawater in the West Daya Bay in 1995 and 1997 and in sediments in 1997. The maximum annual average in seawater was 3.1 Bq/m 3 , annual average of 110m Ag in sediments was 1.0 Bq/kg(dry). But it was always detectable in pearl oyster, gulfweed and cuttlefish in the West Daya Bay. The 110m Ag concentrations in halobios were relatively higher in 1994, 1996 and 1997. The maximum concentrations in pearl oyster, gulfweed and cuttlefish were 2.2, 1.7 and 5.8 Bq/kg (fresh) respectively. It has significantly decreased with decreasing discharge from the stations since 1997. (3) 137 Cs could be detected in almost all seawater samples in the West Daya Bay and the concentration were relatively higher from 1994-1998. The maximum annual average was laid in 1995 and it was 4.6 Bq/m 3 . After 1999, its concentration ranged in the background level. The concentrations in other marine samples were extremely low and changed in the range of the background. (4) 3 H in seawater in the West Daya Bay would go up as a pulse soon after 3 H discharge from the station and would go down to the background after 3-5 days. The annual average of monitoring results were between 0.8-3.4 Bq/L

  10. Monitoring of atmospheric 3H around Narora Atomic Power Station

    International Nuclear Information System (INIS)

    Gautam, Y.P.; Sharma, A.K.; Sharma, S.; Rao, K.S.; Kumar, J.; Kumar, V.; Singh, B.; Kumar, A.; Hedge, A.G.

    2010-01-01

    Atmospheric tritium activity is measured regularly around Narora Atomic Power Station (NAPS) since gaseous waste, which contains tritium, is being released through a 145 m high stack at NAPS site. Atmospheric data collected during 2004-2008 shows a large variation of 3 H concentration in air, fluctuating in the range of ≤0.2-91.6 Bq m -3 . Significantly, higher tritium levels were measured in samples near the site boundary (1.6 km) of NAPS compared to off-site locations. The atmospheric dilution factor was found to be in the range of 1.1 x 10 -7 -7.3 x 10 -7 s m -3 . The scavenging ratio of NAPS site was found to be varying from 0.2 x 10 4 to 14.1 x 10 4 (Bq m -3 rain water per Bq m -3 air). The inhalation dose to a member of general public at different distances (1.6-30 km) from NAPS site was found to be ranged from 0.08-0.21 μSv year -1 . (author)

  11. Local seismic activity monitored at King Sejong Station, Antarctica

    OpenAIRE

    Lee,Duk Kee; Kim,Yea Dong; Nam,Sang Heon; Jin,Young Keun

    1998-01-01

    Source location estimation from single station earthquake data collected at King Sejong Station (62°13'3l"N, 58°47'07"W) from 1995 to 1996 provides seismic activity around King Sejong Station. Analysis of local events, less than 1.5°in angular epicentral distance, finds epicenters located near the Shackleton Fracture Zone, the South Shetland Platform, Deception Island, and North Bransfield Basin. Estimated magnitudes range from 2.2 to 4.5 on the Richter scale, averaging 4.0 in North Bransfiel...

  12. Sea Levels Online: Sea Level Variations of the United States Derived from National Water Level Observation Network Stations

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Water level records are a combination of the fluctuations of the ocean and the vertical land motion at the location of the station. Monthly mean sea level (MSL)...

  13. Directory of Solar-Terrestrial Physics Monitoring Stations.

    Science.gov (United States)

    1984-09-06

    5/-- ---- I sources Toc ated.ADDRE SO , ip j NFUAkTION A0/IT STATIO N . Space Environment Services Center EATA ROU TINIL P/BLISHED N............. O N...SENT TO ARC-C---- ------ DAA oEN TOC _a-A- - - - - - - - - - - - - - - - - - -DATA ARILARLE ON REQUEST--------- YES DATA -EN To-W...FOR INFORMATIOM ABOUT STATION --- N UOSI Dept of Con e Direction d Control de Oeratio Wal Field Station de Sistemas Redioelectritcos P.O. Box S8

  14. Mobile and modular. BGR develops seismological monitoring stations for universal applications; Mobil und modular. BGR entwickelt universell einsetzbare seismologische Messstationen

    Energy Technology Data Exchange (ETDEWEB)

    Hinz, Erwin; Hanneken, Mark [Bundesanstalt fuer Geowissenschaften und Rohstoffe, Hannover (Germany). Fachbereich ' ' Seismologisches Zentralobservatorium, Kernwaffenteststopp' '

    2016-05-15

    BGR seismologists often set up monitoring stations for testing purposes. The engineers from the Central Seismological Observatory have now developed a new type of mobile monitoring station which can be remotely controlled.

  15. Using a noise monitoring station in a small quarry located in an urban area.

    Science.gov (United States)

    Wichers, Michiel; Iramina, Wilson Siguemasa; de Eston, Sérgio Médici; Ayres da Silva, Anna Luiza Marques

    2017-12-22

    Mining plays an important role in Brazilian exports. On the other hand, large urban centers like São Paulo, with approximately 21 million inhabitants, also demand an increasing domestic consumption of natural resources, such as construction aggregate. There are many quarries located in the surroundings of urban centers in Brazil, competing with the growth of urbanized areas. Such proximity leads to a series of conflicts involving quarries and surrounding communities, where the increase in noise levels is highlighted. Operations in quarries, in general, are intermittent. Noisier equipment, such as drilling rigs and primary crushers, operates only a few hours during the day, while other operations, such as screening and secondary and tertiary crushing, are more constant. This paper presents a study carried out in a quarry located near São Paulo, where in addition to conventional short term noise measurements at surrounding receptors, one noise monitoring station was installed, allowing to identify the noisiest moments during the quarry operating time. Through data transmitted by wireless technology, it was possible to follow the noise variations emitted from mining activities in real time and observe the noisiest events that were recorded for events that exceeded the established standards. A mobile application associated to this monitoring station facilitated the quarry's manager and employees to access immediately the monitoring information. Therefore, by using this system, it was possible to evaluate the effectiveness of noise reduction measures already taken and indicate what steps still need to be held.

  16. Development of low cost wireless radiation monitoring station using GSM network

    International Nuclear Information System (INIS)

    Nur Aira Abd Rahman; Mohd Ashhar Khalid; Nor Arymaswati Abdullah; Roslan Md Dan

    2006-01-01

    SMS or Short Message Service is a mean of GSM wireless communication that allow text messages to be sent to and from mobile cell phones. While SMS communication is mainly utilized at personal level or person to person basis; the usage of SMS can be extended into nuclear application specifically in radiation monitoring. This paper explains the development of a wireless station assembled by using a recycled Siemens M50 cell phone as substitutes to GSM modem, a PIC micro controller, and MINT-ISG home made digital survey meter at the remote transmitting site. While at the receiving end; an online monitoring system is set-up by using a Bluetooth enabled cell phone, a Bluetooth dongle, and a PC with Labview 8.0 software written as the Data logger which also served as the PC-Bluetooth interface platform. Wireless station at the remote area operates by continuously sending SMS in every 3 minutes to a predefined cellular number located at the monitoring system. The SMS consists of 6 data which individually is a survey meter readings recorded at each 30 seconds duration. At the receiver, Data logger program will retrieve the SMS from the cell phone via Bluetooth and extract the original 6 readings to be displayed on PC. The system has been successfully tested to detect and log radiation data for extended period of time. (Author)

  17. Preliminary Design of Monitoring and Control Subsystem for GNSS Ground Station

    Directory of Open Access Journals (Sweden)

    Seongkyun Jeong

    2008-06-01

    Full Text Available GNSS (Global Navigation Satellite System Ground Station monitors navigation satellite signal, analyzes navigation result, and uploads correction information to satellite. GNSS Ground Station is considered as a main object for constructing GNSS infra-structure and applied in various fields. ETRI (Electronics and Telecommunications Research Institute is developing Monitoring and Control subsystem, which is subsystem of GNSS Ground Station. Monitoring and Control subsystem acquires GPS and Galileo satellite signal and provides signal monitoring data to GNSS control center. In this paper, the configurations of GNSS Ground Station and Monitoring and Control subsystem are introduced and the preliminary design of Monitoring and Control subsystem is performed. Monitoring and Control subsystem consists of data acquisition module, data formatting and archiving module, data error correction module, navigation solution determination module, independent quality monitoring module, and system operation and maintenance module. The design process uses UML (Unified Modeling Language method which is a standard for developing software and consists of use-case modeling, domain design, software structure design, and user interface structure design. The preliminary design of Monitoring and Control subsystem enhances operation capability of GNSS Ground Station and is used as basic material for detail design of Monitoring and Control subsystem.

  18. Locations of Sampling Stations for Water Quality Monitoring in Water Distribution Networks.

    Science.gov (United States)

    Rathi, Shweta; Gupta, Rajesh

    2014-04-01

    Water quality is required to be monitored in the water distribution networks (WDNs) at salient locations to assure the safe quality of water supplied to the consumers. Such monitoring stations (MSs) provide warning against any accidental contaminations. Various objectives like demand coverage, time for detection, volume of water contaminated before detection, extent of contamination, expected population affected prior to detection, detection likelihood and others, have been independently or jointly considered in determining optimal number and location of MSs in WDNs. "Demand coverage" defined as the percentage of network demand monitored by a particular monitoring station is a simple measure to locate MSs. Several methods based on formulation of coverage matrix using pre-specified coverage criteria and optimization have been suggested. Coverage criteria is defined as some minimum percentage of total flow received at the monitoring stations that passed through any upstream node included then as covered node of the monitoring station. Number of monitoring stations increases with the increase in the value of coverage criteria. Thus, the design of monitoring station becomes subjective. A simple methodology is proposed herein which priority wise iteratively selects MSs to achieve targeted demand coverage. The proposed methodology provided the same number and location of MSs for illustrative network as an optimization method did. Further, the proposed method is simple and avoids subjectivity that could arise from the consideration of coverage criteria. The application of methodology is also shown on a WDN of Dharampeth zone (Nagpur city WDN in Maharashtra, India) having 285 nodes and 367 pipes.

  19. Improving the monitoring of quantitative conditions of peacetime fuel stocks at pumping stations

    Directory of Open Access Journals (Sweden)

    Slaviša M. Ilić

    2011-04-01

    human resources. Optimization of quantitative monitoring of peacetime supplies of fuel at gas stations should aim at reducing the impact of the human factor, introducing automated quantitative monitoring of fuel condition with modern equipment for handling as well as applying technology for fast reading and dissemination of information and reports. Civilian pumping stations have been modernized gradually with new digital pump machines, systems for automated production and automated systems for measuring the fuel level in buried tanks. The objectives and criteria of the optimization of model monitoring In order to solve the problem of multi-criteria nature, the methods of operational research have been applied and the formalization of problem solving has been carried out. Models have been identified, criteria and subcriteria have been defined as well as respective criteria values, sub-criteria and weight coefficients for chosen variants in order to rank the alternatives - models. On the basis of the defined objectives and optimization approaches, the task of optimization to be solved is to choose one optimal model of monitoring the quantitative condition of peacetime stocks of fuels at gas stations, out of three variations or alternative models. Application of expert assessment and methods of analytical hierarchy process The problem was solved first 'manually', by using MS Excell, and after that by using the Expert Choice software package. The Expert Choice software package is based on the application of the method of analytical hierarchy process and combines the benefits that this method offers with the speed and visibility of computerized calculations and their result display. The purpose of the AHP method is to rank alternative decisions by their importance and to select the most acceptable alternative on the basis of a defined set of criteria and alternatives. The problem of determining the weight of criteria has been determined by applying the method of expert

  20. 25 years of monitoring the Waste Management Center of the Almirante Alvaro Alberto Nuclear Power Station

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, O.C; Barboza, E.; Cardoso, S.N.M., E-mail: landocf@eletronuclear.gov.br, E-mail: barboza@eletronuclear.gov.br, E-mail: sergion@eletronuclear.gov.br [Eletrobras Eletronuclear S.A (ELETONUCLEAR), Paraty, RJ (Brazil). Lab. de Monitoracao Ambiental

    2013-07-01

    The goal of this paper is to present an assessment of 25 years of monitoring of the environment around the Waste Management Center (WMC) of the Almirante Alvaro Alberto Nuclear Power Station (AAANPS) since 1986 until 2011. The Environmental Monitoring Laboratory (EML) has, for purposes, to monitor the environment around the station to verify if there's a potential impact caused by the operation of the two units and to verify the dose rate levels around the waste deposits. The WMC is located in an area belonging to the AAANPS and receive solid waste of low and medium activities from Angra 1 NPP. The waste generated from Angra 2 NPP is stored inside the unit. The EML monitors the environment around the WMC to determine the environmental dose rate. The monitoring is made by direct measurement of the radiation using thermoluminescent dosimeters (TLD). Nowadays, the TLD are installed, at this time, in 6 points at the boundaries of WMC and are changed monthly. The locations of these points were already changed several times to allow the construction of new buildings. The constitution of the TLD are 4 crystals, being 3 crystals of Calcium Sulphate doped with Thulium (CaSO{sub 4}:Tm) with 3 shields and 1 crystal of Lithium Borate doped with Copper (Li{sub 2}B{sub 4}O{sub 7}:Cu) without shield. The results of the TLD measurements are normalized to a period of 30 days to compensate accidental statistical variations of the dose rates. The results, in these 25 years, show that the external area of the WMC is a supervised area, following the Norm CNEN-NN-3.01 - 'Diretrizes Basicas de Protecao Radiologica' - with access permitted only for authorized people. (author)

  1. 25 years of monitoring the Waste Management Center of the Almirante Alvaro Alberto Nuclear Power Station

    International Nuclear Information System (INIS)

    Ferreira, O.C; Barboza, E.; Cardoso, S.N.M.

    2013-01-01

    The goal of this paper is to present an assessment of 25 years of monitoring of the environment around the Waste Management Center (WMC) of the Almirante Alvaro Alberto Nuclear Power Station (AAANPS) since 1986 until 2011. The Environmental Monitoring Laboratory (EML) has, for purposes, to monitor the environment around the station to verify if there's a potential impact caused by the operation of the two units and to verify the dose rate levels around the waste deposits. The WMC is located in an area belonging to the AAANPS and receive solid waste of low and medium activities from Angra 1 NPP. The waste generated from Angra 2 NPP is stored inside the unit. The EML monitors the environment around the WMC to determine the environmental dose rate. The monitoring is made by direct measurement of the radiation using thermoluminescent dosimeters (TLD). Nowadays, the TLD are installed, at this time, in 6 points at the boundaries of WMC and are changed monthly. The locations of these points were already changed several times to allow the construction of new buildings. The constitution of the TLD are 4 crystals, being 3 crystals of Calcium Sulphate doped with Thulium (CaSO 4 :Tm) with 3 shields and 1 crystal of Lithium Borate doped with Copper (Li 2 B 4 O 7 :Cu) without shield. The results of the TLD measurements are normalized to a period of 30 days to compensate accidental statistical variations of the dose rates. The results, in these 25 years, show that the external area of the WMC is a supervised area, following the Norm CNEN-NN-3.01 - 'Diretrizes Basicas de Protecao Radiologica' - with access permitted only for authorized people. (author)

  2. Proposed Construction of Boulder Seismic Station Monitoring Sites, Boulder, Wyoming. Environmental Assessment

    Science.gov (United States)

    2009-02-01

    boreholes at the Boulder Seismic Station for research, development, test, and evaluation (RDT&E) as part of the U.S. Nuclear Treaty monitoring...14 LIST OF FIGURES Figure 1. Location of the proposed Boulder Seismic Station, borehole locations and associated buffers...juncture of Spring Creek and Scab Creek Road (Figure 1). Currently, the Boulder Seismic Station has a 13-element array of seismometers on the property

  3. 2. All-Polish Seminar: Monitoring of Radioactive Environment Contamination Using ASS-500 and PMS Stations

    International Nuclear Information System (INIS)

    1998-01-01

    During last 10 years the modern system of radiological pollution monitoring has been developed in Poland. At the beginning it was composed of ASS-500 stations. At the end of 1995 five automatic PMS stations have been installed as the result of the collaboration between Polish and Danish governments. Several stations of both types were include later. The system is coordinated by Central Laboratory for Radiological Protection. The report reviews the meeting dedicated to problems and future developments of the system

  4. Monitoring the Performance of the Pedestrian Transfer Function of Train Stations Using Automatic Fare Collection Data

    NARCIS (Netherlands)

    Van den Heuvel, J.P.A.; Hoogenraad, J.H.

    2014-01-01

    Over the last years all train stations in The Netherlands have been equipped with automatic fare collection gates and/or validators. All public transport passengers use a smart card to pay their fare. In this paper we present a monitor for the performance of the pedestrian function of train stations

  5. 40 CFR 52.2035 - Photochemical Assessment Monitoring Stations (PAMS) Program.

    Science.gov (United States)

    2010-07-01

    ... Stations (PAMS) Program. 52.2035 Section 52.2035 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...) Pennsylvania § 52.2035 Photochemical Assessment Monitoring Stations (PAMS) Program. On September 23, 1994... (PAMS) Program as a state implementation plan (SIP) revision, as required by section 182(c)(1) of the...

  6. Air pollution assessment in the Slovak Republic in 2005. Measurement stations of air quality monitoring network

    International Nuclear Information System (INIS)

    Anon

    2006-05-01

    In this Appendix to the report 'Air pollution assessment in the Slovak Republic in 2005' the main characteristics of measurement stations of air quality monitoring network of the Slovak Republic are presented

  7. Air pollution assessment in the Slovak Republic in 2004. Measurement stations of air quality monitoring network

    International Nuclear Information System (INIS)

    Anon

    2005-07-01

    In this Appendix to the report 'Air pollution assessment in the Slovak Republic in 2004' the main characteristics of measurement stations of air quality monitoring network of the Slovak Republic are presented

  8. Environmental radiation monitoring data for Point Lepreau Generating Station, 1988. Annual publication

    Energy Technology Data Exchange (ETDEWEB)

    Sutherland, J K

    1989-01-01

    Annual report presenting a compilation of the 1988 environmental radiation monitoring program data from samples collected around the Point Lepreau Nuclear Generating Station (PLNGS) and at reference stations remote from PLNGS. About 1,700 analyses were made on 1,200 samples to monitor environmental radiation, including air filters, airborne water vapour, sea water, well water, milk, beach sediments, clams, fish, lobster, dulse, crabs, scallops and lichen. Background radiation is measured by thermoluminescence dosimetry.

  9. Environmental radiation monitoring data for Point Lepreau Generating Station, 1987. Annual publication

    Energy Technology Data Exchange (ETDEWEB)

    Sutherland, J K

    1988-01-01

    Annual report presenting a compilation of the 1987 environmental radiation monitoring program data from samples collected around the Point Lepreau Nuclear Generating Station (PLNGS) and at reference stations remote from PLNGS. About 1,800 analyses were made on 1,300 samples to monitor environmental radiation, including air filters, airborne water vapour, sea water, well water, milk, beach sediments, clams, fish, lobster, dulse, crabs, scallops and periwinkles. Background radiation is measured by thermoluminescence dosimetry.

  10. Impacts on particles and ozone by transport processes recorded at urban and high-altitude monitoring stations

    Energy Technology Data Exchange (ETDEWEB)

    Nicolás, J.F., E-mail: j.nicolas@umh.es [Laboratory of Atmospheric Pollution (LCA), Miguel Hernández University, Av. de la Universidad s/n, Edif. Alcudia, 03202 Elche (Spain); Crespo, J.; Yubero, E.; Soler, R. [Laboratory of Atmospheric Pollution (LCA), Miguel Hernández University, Av. de la Universidad s/n, Edif. Alcudia, 03202 Elche (Spain); Carratalá, A. [Department of Chemical Engineering, University of Alicante, P.O. Box 99, 03080 Alicante (Spain); Mantilla, E. [Instituto Universitario CEAM-UMH, Parque Tecnológico, C/Charles R. Darwin 14, E-46980 Paterna (Spain)

    2014-01-01

    In order to evaluate the influence of particle transport episodes on particle number concentration temporal trends at both urban and high-altitude (Aitana peak-1558 m a.s.l.) stations, a simultaneous sampling campaign from October 2011 to September 2012 was performed. The monitoring stations are located in southeastern Spain, close to the Mediterranean coast. The annual average value of particle concentration obtained in the larger accumulation mode (size range 0.25–1 μm) at the mountain site, 55.0 ± 3.0 cm{sup − 3}, was practically half that of the value obtained at the urban station (112.0 ± 4.0 cm{sup − 3}). The largest difference between both stations was recorded during December 2011 and January 2012, when particles at the mountain station registered the lowest values. It was observed that during urban stagnant episodes, particle transport from urban sites to the mountain station could take place under specific atmospheric conditions. During these transports, the major particle transfer is produced in the 0.5–2 μm size range. The minimum difference between stations was recorded in summer, particularly in July 2012, which is most likely due to several particle transport events that affected only the mountain station. The particle concentration in the coarse mode was very similar at both monitoring sites, with the biggest difference being recorded during the summer months, 0.4 ± 0.1 cm{sup − 3} at the urban site and 0.9 ± 0.1 cm{sup − 3} at the Aitana peak in August 2012. Saharan dust outbreaks were the main factor responsible for these values during summer time. The regional station was affected more by these outbreaks, recording values of > 4.0 cm{sup − 3}, than the urban site. This long-range particle transport from the Sahara desert also had an effect upon O{sub 3} levels measured at the mountain station. During periods affected by Saharan dust outbreaks, ozone levels underwent a significant decrease (3–17%) with respect to its mean

  11. Impacts on particles and ozone by transport processes recorded at urban and high-altitude monitoring stations

    International Nuclear Information System (INIS)

    Nicolás, J.F.; Crespo, J.; Yubero, E.; Soler, R.; Carratalá, A.; Mantilla, E.

    2014-01-01

    In order to evaluate the influence of particle transport episodes on particle number concentration temporal trends at both urban and high-altitude (Aitana peak-1558 m a.s.l.) stations, a simultaneous sampling campaign from October 2011 to September 2012 was performed. The monitoring stations are located in southeastern Spain, close to the Mediterranean coast. The annual average value of particle concentration obtained in the larger accumulation mode (size range 0.25–1 μm) at the mountain site, 55.0 ± 3.0 cm − 3 , was practically half that of the value obtained at the urban station (112.0 ± 4.0 cm − 3 ). The largest difference between both stations was recorded during December 2011 and January 2012, when particles at the mountain station registered the lowest values. It was observed that during urban stagnant episodes, particle transport from urban sites to the mountain station could take place under specific atmospheric conditions. During these transports, the major particle transfer is produced in the 0.5–2 μm size range. The minimum difference between stations was recorded in summer, particularly in July 2012, which is most likely due to several particle transport events that affected only the mountain station. The particle concentration in the coarse mode was very similar at both monitoring sites, with the biggest difference being recorded during the summer months, 0.4 ± 0.1 cm − 3 at the urban site and 0.9 ± 0.1 cm − 3 at the Aitana peak in August 2012. Saharan dust outbreaks were the main factor responsible for these values during summer time. The regional station was affected more by these outbreaks, recording values of > 4.0 cm − 3 , than the urban site. This long-range particle transport from the Sahara desert also had an effect upon O 3 levels measured at the mountain station. During periods affected by Saharan dust outbreaks, ozone levels underwent a significant decrease (3–17%) with respect to its mean value. - Highlights:

  12. Environmental monitoring report for the Point Lepreau, New Brunswick nuclear generating station 1984

    International Nuclear Information System (INIS)

    Nelson, R.W.P.; Ellis, K.M.; Smith, J.N.

    1986-07-01

    The Point Lepreau Environmental Monitoring Program (PLEMP) has been established within the Department of Fisheries and Oceans to assess the environmental impact of radioactive, thermal, and chemical releases from the Point Lepreau, N.B. Nuclear Generating Station (NGS) located on the Bay of Fundy. This report contains the results for the second year of the operational phase of the monitoring program. Emphasis has been placed on those areas where effects from the NGS operation were expected to be observed. Further studies were carried out on the characterization of the thermal plume during several pre-arranged tritium releases. Attention was given to tritium levels at the outfall, in the atmosphere and in biological samples. An initial attempt was made to relate the distribution of tritium in the Point Lepreau area in various phases to local meteorological conditions. Radionuclide levels in lichen, including, for the first time, aerial lichen on a regular basis, an efficient accumulator of atmospheric particulates were monitored. In addition, radionuclide measurements were made on samples collected during the pre-operational phase from the major environmental reservoirs and these radioactivity levels were compared to previous measurements to assess the impact of the operation of the NGS. The purpose of this program is to provide government with a comprehensive scientific basis upon which to assess the environmental implications of the operation of nuclear reactors in coastal regions

  13. High level waste (HLW) steam reducing station evaluation

    International Nuclear Information System (INIS)

    Gannon, R.E.

    1993-01-01

    Existing pressure equipment in High Level Waste does not have a documented technical baseline. Based on preliminary reviews, the existing equipment seems to be based on system required capacity instead of system capability. A planned approach to establish a technical baseline began September 1992 and used the Works Management System preventive maintenance schedule. Several issues with relief valves being undersized on steam reducing stations created a need to determine the risk of maintaining the steam in service. An Action Plan was developed to evaluate relief valves that did not have technical baselines and provided a path forward for continued operation. Based on Action Plan WER-HLE-931042, the steam systems will remain in service while the designs are being developed and implemented

  14. Vibration monitoring of large vertical pumps via a remote satellite station

    International Nuclear Information System (INIS)

    Cook, S.A.; Crowe, R.D.; Roblyer, S.P.; Toffer, H.

    1985-01-01

    The Hanford N Reactor is operated by UNC Nuclear Industries for the Department of Energy for the production of special isotopes and electric energy. The reactor has a unique design in which the equipment such as pumps, turbines, generators and diesel engines are located in separate buildings. This equipment arrangement has led to the conclusion that the most cost-effective implementation of a dedicated vibration monitoring system would be to install a computerized network system in lieu of a single analyzing station. In this approach, semi-autonomous micro processor based data collection stations referred to as satellite stations are located near each concentration of machinery to be monitored. The satellite stations provide near continuous monitoring of the machinery. They are linked to a minicomputer using voice grade telephone circuits and hardware and software specifically designed for network communications. The communications link between the satellite stations and the minicomputer permits data and programs to be transmitted between the units. This paper will describe the satellite station associated with large vertical pumps vibration monitoring. The reactor has four of these pumps to supply tertiary cooling to reactor systems. 4 figs

  15. Operability test procedure for the TK-900 effluent monitoring station

    International Nuclear Information System (INIS)

    Weissenfels, R.D.

    1994-01-01

    This procedure will verify that the 221-B liquid effluent monitoring system, installed near the east end of the 6-in. chemical sewer header, functions as intended by design. TK-900B was installed near stairwell 3 in the 221-B electrical gallery by Project W-007H. The system is part of BAT/AKART for the BCE liquid effluent system

  16. Pilot Water Quality Monitoring Station in Dublin Bay North Bank Monitoring Station (NBMS): MATSIS Project Part I

    OpenAIRE

    O Donnell, G.; Joyce, E.; O Boyle, S.; McGovern, E.

    2008-01-01

    The lack of short-term temporal resolution associated with traditional spot sampling for monitoring water quality of dynamic coastal and estuarine waters has meant that many organisations are interesting in autonomous monitoring technologies to provide near real-time semi-continuous data. Such approaches enable capturing short term episodic events (which may be missed or alternatively skew datasets when using spot samples) and provide early warning of water quality problems. New policy driver...

  17. [Space-time water monitoring system at the Iriklinsk hydroelectric power station].

    Science.gov (United States)

    Deriabin, D G; Poliakov, E G; Priakhina, A A; Karimov, I F

    2002-01-01

    The Microbiosensor B 17677 F test system was applied to make a space-time monitoring of the biotoxicity of water used for production and everyday purposes at the Iriklinsk hydroelectric power station (IHEPS) and to identify the leading causes determining the biotoxicity of tested samples. There were seasonal variations in the biotoxicity with the maximum in spring and with minimum in winter and spring and a relationship of the spring rise in the biotoxicity to water pH changes. There was also an association of the certain values of the biotoxicity of industrial water with the concentration of petroleum products that are major pollutants at the IHEPS. The datum points that characterize the maximum level of technogenic exposure were identified.

  18. Water level monitoring device in nuclear reactor

    International Nuclear Information System (INIS)

    Miura, Kiyohide; Otake, Tomohiro.

    1988-01-01

    Purpose: To monitor the water level in a pressure vessel of BWR type nuclear reactors at high accuracy by improving the compensation functions. Constitution: In the conventional water level monitor in a nuclear reactor, if the pressure vessel is displaced by the change of the pressure in the reactor or the temperature of the reactor water, the relative level of the reference water head in a condensation vessel is changed to cause deviation between the actual water level and the indicated water level to reduce the monitoring accuracy. According to the invention, means for detecting the position of the reference water head and means for detection the position in the condensation vessel are disposed to the pressure vessel. Then, relative positional change between the condensation vessel and the reference water head is calculated based on detection sinals from both of the means. The water level is compensated and calculated by water level calculation means based on the relative positional change, water level signals from the level gage and the pressure signals from the pressure gage. As a result, if the pressure vessel is displaced due to the change of the temperature or pressure, it is possible to measure the reactor water level accurately thereby remakably improve the reliability for the water level control in the nuclear reactor. (Horiuchi, T.)

  19. Setup and Calibration of SLAC's Peripheral Monitoring Stations

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, C.

    2004-09-03

    The goals of this project were to troubleshoot, repair, calibrate, and establish documentation regarding SLAC's (Stanford Linear Accelerator Center's) PMS (Peripheral Monitoring Station) system. The PMS system consists of seven PMSs that continuously monitor skyshine (neutron and photon) radiation levels in SLAC's environment. Each PMS consists of a boron trifluoride (BF{sub 3}) neutron detector (model RS-P1-0802-104 or NW-G-20-12) and a Geiger Moeller (GM) gamma ray detector (model TGM N107 or LND 719) together with their respective electronics. Electronics for each detector are housed in Nuclear Instrument Modules (NIMs) and are plugged into a NIM bin in the station. All communication lines from the stations to the Main Control Center (MCC) were tested prior to troubleshooting. To test communication with MCC, a pulse generator (Systron Donner model 100C) was connected to each channel in the PMS and data at MCC was checked for consistency. If MCC displayed no data, the communication cables to MCC or the CAMAC (Computer Automated Measurement and Control) crates were in need of repair. If MCC did display data, then it was known that the communication lines were intact. All electronics from each station were brought into the lab for troubleshooting. Troubleshooting usually consisted of connecting an oscilloscope or scaler (Ortec model 871 or 775) at different points in the circuit of each detector to record simulated pulses produced by a pulse generator; the input and output pulses were compared to establish the location of any problems in the circuit. Once any problems were isolated, repairs were done accordingly. The detectors and electronics were then calibrated in the field using radioactive sources. Calibration is a process that determines the response of the detector. Detector response is defined as the ratio of the number of counts per minute interpreted by the detector to the amount of dose equivalent rate (in mrem per hour, either calculated

  20. Radioactive aerosol detection station for near real-time atmospheric monitoring

    International Nuclear Information System (INIS)

    Mason, L.R.; Bohner, John D.

    1997-01-01

    A radionuclide aerosol detection station has been developed to measure radioactivity in the environment. The objective is to monitor the atmosphere for anthropogenic radioactivity that could be indicative of nuclear weapons tests to verify the Comprehensive Nuclear Test Ban Treaty. Eighty stations will form the backbone of the International Monitoring System in which stations are linked to a central analysis facility called the International Data Centre. Data are transmitted to this centre in near real-time to facilitate rapid detection. Principal process of the field measurement are collection, separation, and assay. Collection of airborne radioactivity is achieved through high-volume air sampling. Aerosols separation is accomplished by high-efficiency particulate filtration. Radionuclides assay is achieved by in-situ high resolution gamma spectrometry. These modules are integrated into a unit that provides power, control, and communication support subsystems. Station operation is semi-automatic requiring only minimal human interaction. (author). 6 refs., 3 figs., 3 tabs

  1. Monitoring of radioactivity in the environs of Finnish nuclear power stations in 1986

    International Nuclear Information System (INIS)

    Ilus, E.; Sjoeblom, K.L.; Aaltonen, H.; Klemola, S.; Arvela, H.

    1987-06-01

    Results of the environmental programmes monitoring radioactivity around the Finnish nuclear power stations in 1986 are reported. After the end of April the fallout nuclides from the Chernobyl accident predominated in all samples taken from the environs of the two power stations Loviisa and Olkiluoto. Radionuclides originating from the Finnish power stations were detected mainly in samples taken from the aquatic environment. The concentrations of the locally discharged nuclides were very low in comparison with the fallout nuclides and their impact on the radiation doses of the population was insignificant. Both nuclear power stations are situated in the main fallout area in Finland. The results of these large monitoring programmes give a good picture of the behaviour of the Chernobyl fallout in the specific areas in Finland

  2. National Coral Reef Monitoring Program: Benthic Complexity and Urchin Abundance at Climate Stations of the Mariana Archipelago since 2014

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The benthic complexity and urchin abundance monitoring effort provides baselines for tracking these variables at NCRMP climate stations. Climate stations are 3-4...

  3. National Coral Reef Monitoring Program: Benthic Complexity and Urchin Abundance at Climate Stations of the Hawaiian Archipelago since 2013

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The benthic complexity and urchin abundance monitoring effort provides baselines for tracking these variables at NCRMP climate stations. Climate stations are 3-4...

  4. National Coral Reef Monitoring Program: Benthic Complexity and Urchin Abundance at Climate Stations of American Samoa in 2015

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The benthic complexity and urchin abundance monitoring effort provides baselines for tracking these variables at NCRMP climate stations. Climate stations are 3-4...

  5. Alarm criteria for the fixed gamma radiation monitoring stations

    International Nuclear Information System (INIS)

    Kjelle, P.E.

    1987-01-01

    For the type of measurement considered here, an alarm based on the dose excess has been shown to be a more certain method of indicating that a true alarm situation exists than an alarm based on the dose-rate exceeding a given dose-rate level. The method offers a number of advantages: Dose-rate levels can be recorded over long periods without any necessity of making manual changes in the alarm level due to seasonal variations in the background level. A relatively low level can be specified without an unnecessary number of false alarms being triggered by gamma-emitting radon daughters. (orig./HP)

  6. Monitoring Method and Apparatus Using Asynchronous, One-Way Transmission from Sensor to Base Station

    Science.gov (United States)

    Jensen, Scott L. (Inventor); Drouant, George J. (Inventor)

    2013-01-01

    A monitoring system is disclosed, which includes a base station and at least one sensor unit that is separate from the base station. The at least one sensor unit resides in a dormant state until it is awakened by the triggering of a vibration-sensitive switch. Once awakened, the sensor may take a measurement, and then transmit to the base station the measurement. Once data is transmitted from the sensor to the base station, the sensor may return to its dormant state. There may be various sensors for each base station and the various sensors may optionally measure different quantities, such as current, voltage, single-axis and/or three-axis magnetic fields.

  7. Monitoring biofouling in the seawater tunnel of a coastal power station

    International Nuclear Information System (INIS)

    Sasikumar, N.

    1994-01-01

    Water level difference (head loss) between the seawater intake and the forebay was used to determine the biofouling growth in the cooling-water tunnel of Madras atomic power station, India. During 1986-87, due to biofouling growth in the tunnel, the head loss dropped beyond the permissible limits required for operation of the power plant. The head loss showed an improvement during 1988 and 1989, after exomotive chlorination was adopted instead of shock chlorination. Fouling biomass estimated from the head loss showed a heavy biomass build-up of 535.52 ± 102 tonnes in the tunnel during 1992. The head loss showed a seasonal pattern, very similar to the settlement pattern of foulants in the coastal waters, with maximum values during summer months. On the basis of head-loss data, a suitable chlorination practice has been recommended to the power station. The experience suggested that a continuous monitoring of head loss is a simple and reliable method of estimating and controlling biofouling in power-plant cooling-water tunnels. (author)

  8. Comprehensive Test Ban Treaty (CTBT) monitoring station operating regime influence on radionuclide detection sensitivity

    International Nuclear Information System (INIS)

    Williams, D.L.

    1999-01-01

    International Monitoring System (IMS) stations are being deployed worldwide in support of the Comprehensive [Nuclear] Test Ban Treaty (CTBT). The highly sensitive radionuclide monitoring stations regularly sample airborne radionuclide particulates to determine whether fission products are present in the atmosphere that may be indicative of a nuclear weapons test. Standards have been set for these stations regarding their operation regime and the minimum detectable concentrations (MDCs) for specific radionuclides likely to be present after a nuclear weapons test. This study uses actual CTBT monitoring data to relate a subset of the specified operational standards with the listed MDC limits. It is determined that a relationship exists between the specified operational regime and the MDC values. Since the background radioactivity is largely a function of the radon and thoron progeny, longer decay operational regimes allow for a reduction in the background. For longer lived radionuclides, this corresponds to a reduction in MDC. (author)

  9. Environmental radiation monitoring data for Point Lepreau Generating Station, 1990. Annual publication

    Energy Technology Data Exchange (ETDEWEB)

    Sutherland, J K

    1991-01-01

    Annual report presenting a compilation of the 1990 environmental radiation monitoring program data from samples collected around the Point Lepreau Nuclear Generating Station (PLNGS) and at reference stations remote from PLNGS. About 1,500 analyses were made on 1,100 samples to monitor environmental radiation, including air particulates, airborne water vapour, carbon dioxide in air, sea water, well water, milk, beach sediments, clams, fish, lobster, dulse, crabs, scallops, periwinkles, sea plants and lichen. Background radiation is measured by thermoluminescence dosimetry. Radon is not assessed.

  10. The status and prospective of environmental radiation monitoring stations in Saudi Arabia

    Science.gov (United States)

    Al-Kheliewi, Abdullah S.; Holzheimer, Clous

    2014-09-01

    The use of nuclear technology requires an environmental monitoring program to ensure the safety of the environment, and to protect people from the hazards of radioactive materials, and nuclear accidents. Nuclear accidents are unique, for they incur effects that surpass international frontiers, and can even have a long lasting impact on Earth. Such was the case of the Chernobyl accident in the Ukraine on April 6, 1986. For that purpose, international and national efforts come together to observe for any nuclear or radioactive accident. Many states, including Saudi Arabia which oversees the operation of the National Radiation, Environmental and Early Monitoring Stations, The Radiation Monitoring Stations(RMS's) are currently scattered across 35 cities in the country,. These locations are evaluated based on various technological criteria such as border cities, cities of high population density, wind direction, etc. For new nuclear power plants hovering around, it is strongly recommended to increase the number of radiation monitoring stations to warn against any threat that may arise from a nuclear leak or accident and to improve the performance of the existing RMS's. SARA (Spectroscopic Monitoring Station for air) should be implemented due to the high sensitivity to artificial radiation, automatic isotope identification, free of maintenance, and fully independent due to solar power supply (incl. battery backup) and wireless communication (GPRS).

  11. The status and prospective of environmental radiation monitoring stations in Saudi Arabia

    International Nuclear Information System (INIS)

    Al-Kheliewi, Abdullah S.; Holzheimer, Clous

    2014-01-01

    The use of nuclear technology requires an environmental monitoring program to ensure the safety of the environment, and to protect people from the hazards of radioactive materials, and nuclear accidents. Nuclear accidents are unique, for they incur effects that surpass international frontiers, and can even have a long lasting impact on Earth. Such was the case of the Chernobyl accident in the Ukraine on April 6, 1986. For that purpose, international and national efforts come together to observe for any nuclear or radioactive accident. Many states, including Saudi Arabia which oversees the operation of the National Radiation, Environmental and Early Monitoring Stations, The Radiation Monitoring Stations(RMS’s) are currently scattered across 35 cities in the country,. These locations are evaluated based on various technological criteria such as border cities, cities of high population density, wind direction, etc. For new nuclear power plants hovering around, it is strongly recommended to increase the number of radiation monitoring stations to warn against any threat that may arise from a nuclear leak or accident and to improve the performance of the existing RMS’s. SARA (Spectroscopic Monitoring Station for air) should be implemented due to the high sensitivity to artificial radiation, automatic isotope identification, free of maintenance, and fully independent due to solar power supply (incl. battery backup) and wireless communication (GPRS)

  12. The status and prospective of environmental radiation monitoring stations in Saudi Arabia

    Energy Technology Data Exchange (ETDEWEB)

    Al-Kheliewi, Abdullah S. [National Center for Radiation Protection, King Abdulaziz City for Science and Technology, 11442 Riyadh (Saudi Arabia); Holzheimer, Clous [ENVINET GmbH, Environmental Radiation Detection, Hans-Pinsel-Straße 4, 85540 Haar (Munich) (Germany)

    2014-09-30

    The use of nuclear technology requires an environmental monitoring program to ensure the safety of the environment, and to protect people from the hazards of radioactive materials, and nuclear accidents. Nuclear accidents are unique, for they incur effects that surpass international frontiers, and can even have a long lasting impact on Earth. Such was the case of the Chernobyl accident in the Ukraine on April 6, 1986. For that purpose, international and national efforts come together to observe for any nuclear or radioactive accident. Many states, including Saudi Arabia which oversees the operation of the National Radiation, Environmental and Early Monitoring Stations, The Radiation Monitoring Stations(RMS’s) are currently scattered across 35 cities in the country,. These locations are evaluated based on various technological criteria such as border cities, cities of high population density, wind direction, etc. For new nuclear power plants hovering around, it is strongly recommended to increase the number of radiation monitoring stations to warn against any threat that may arise from a nuclear leak or accident and to improve the performance of the existing RMS’s. SARA (Spectroscopic Monitoring Station for air) should be implemented due to the high sensitivity to artificial radiation, automatic isotope identification, free of maintenance, and fully independent due to solar power supply (incl. battery backup) and wireless communication (GPRS)

  13. Monitoring and managing component fatigue at Point Lepreau Generating Station

    International Nuclear Information System (INIS)

    Stevens, G.L.; Yetisir, M.; Scovil, A.; Slade, J.

    2008-01-01

    Many CANDU plants are now approaching the end of their design lives and are being considered for extended operation beyond their design life. The Canadian Nuclear Safety Commission (CNSC) has asked utilities to address component fatigue issues in plant life extension (PLEX) applications. In particular, environmental effects on fatigue was identified as an issue that needs to be addressed, similar to being addressed for license renewal for U.S. nuclear power plants. To address CNSC concerns, the CANDU Owners Group (COG) has initiated a program to help utilities develop component fatigue management programs for PLEX operation. A summary of a pilot study that was conducted at the Point Lepreau Generating Station (PLGS) is provided below: A plant-specific Recommendation Study provided a comprehensive review of the existing plant-specific systems, cycle counting procedures, and other fatigue-related requirements, and made some general recommendations on how best to implement a fatigue management system for PLEX. The plant-specific study determined that only 10 to 15% of the design transients have been used after 25 effective full power years (EFPY) of operation. Hence, a significant amount of original design margin for fatigue usage margin remains available for PLEX operation. Environmental fatigue considerations in heavy water (D 2 O) were included in the plant-specific assessment. Only warm-up transients were assessed to have dissolved oxygen concentrations that can result in a significant environmental effect for the ferritic steels used in the CANDU primary systems. Due to the low accumulation of transients and the absence of known thermal stratification mechanisms, thermal fatigue is not as significant an issue in CANDU plants as in pressurized water reactor (PWR) and boiling water reactor (BWR) plants. The needs for implementing a comprehensive Fatigue Management Program for PLGS to satisfy PLEX requirements were defined, and specific direction and strategy for

  14. Evolution of occupational exposure to environmental levels of aromatic hydrocarbons in service stations.

    Science.gov (United States)

    Periago, J F; Prado, C

    2005-04-01

    During refuelling, people may easily be exposed to extremely high levels of gasoline vapour for a short time, although such exposure takes on more importance in the case of service station attendants. The volume of gasoline sold in refuelling operations and the ambient temperature can significantly increase the environmental level of benzene, toluene and xylene (BTX) vapours and, subsequently, the occupational risk of service station attendants. This is especially true in the case of benzene, the most important component of gasoline vapours from a toxicological point of view. The European Directive 98/70/EC, limiting the benzene composition of gasoline, and 94/63/EC, concerning the use of vapour recovery systems in the delivery of gasoline to services stations, were applied in Spain from January 2000 and 2002, respectively. In addition, a new limit value for occupational exposure of 3.25 mg/m(3) was fixed for benzene in Directive 97/42/EC, applied from June 2003. However, recent years have seen the growing use of diesel as well as of unleaded and reformulated gasoline. In this study, we analyse the differences found between air concentration levels of BTXs in 2000 and 2003, analysing samples taken from the personal breathing-zone of occupationally exposed workers in service stations. The results are compared with those obtained in a similar study carried out in 1995 (before the new regulations came into force). The study was carried out in two phases. The first phase was carried out in 2000, after application of the new legal regulation limiting the benzene concentration in gasoline. In this case, an occupationally exposed population of 28 service station attendants was sampled in July, with a mean ambient temperature of 30-31 degrees C. In the second phase, 19 exposed subjects were sampled in July 2003, one of the warmest months in recent years with mean temperatures of 35-36 degrees C during the time of exposure monitoring. The results were then compared with

  15. Geodetic infrastructure at the Barcelona harbour for sea level monitoring

    Science.gov (United States)

    Martinez-Benjamin, Juan Jose; Gili, Josep; Lopez, Rogelio; Tapia, Ana; Pros, Francesc; Palau, Vicenc; Perez, Begona

    2015-04-01

    The presentation is directed to the description of the actual geodetic infrastructure of Barcelona harbour with three tide gauges of different technologies for sea level determination and contribution to regional sea level rise and understanding past and present sea level rise in the Barcelona harbour. It is intended that the overall system will constitute a CGPS Station of the ESEAS (European Sea Level) and TIGA (GPS Tide Gauge Benchmark Monitoring) networks. At Barcelona harbour there is a MIROS radar tide gauge belonging to Puertos del Estado (Spanish Harbours).The radar sensor is over the water surface, on a L-shaped structure which elevates it a few meters above the quay shelf. 1-min data are transmitted to the ENAGAS Control Center by cable and then sent each 1 min to Puertos del Estado by e-mail. The information includes wave forescast (mean period, significant wave height, sea level, etc.This sensor also measures agitation and sends wave parameters each 20 min. There is a GPS station Leica Geosystems GRX1200 GG Pro and antenna AX 1202 GG. The Control Tower of the Port of Barcelona is situated in the North dike of the so-called Energy Pier in the Barcelona harbor (Spain). This tower has different kind of antennas for navigation monitoring and a GNSS permanent station. As the tower is founded in reclaimed land, and because its metallic structure, the 50 m building is subjected to diverse movements, including periodic fluctuations due to temperature changes. In this contribution the 2009, 2011, 2012, 2013 and 2014 the necessary monitoring campaigns are described. In the framework of a Spanish Space Project, the instrumentation of sea level measurements has been improved by providing the Barcelona site with a radar tide gauge Datamar 2000C from Geonica S.L. in June 2014 near an acoustic tide gauge from the Barcelona Harbour installed in 2013. Precision levelling has been made several times in the last two years because the tower is founded in reclaimed land and

  16. CONCEPTUAL DESIGN OF MONITORING AND CONTROL SUBSYSTEM FOR GNSS GROUND STATION

    Directory of Open Access Journals (Sweden)

    Seongkyun Jeong

    2007-12-01

    Full Text Available The Global Navigation Satellite System (GNSS becomes more important and is applied to various systems. Recently, the Galileo navigation system is being developed in Europe. Also, other countries like China, Japan and India are developing the global/regional navigation satellite system. As various global/regional navigation satellite systems are used, the navigation ground system gets more important for using the navigation system reasonably and efficiently. According to this trend, the technology of GNSS Ground Station (GGS is developing in many fields. The one of purposes for this study is to develop the high precision receiver for GNSS sensor station and to provide ground infrastructure for better performance services on navigation system. In this study, we consider the configuration of GNSS Ground Station and analyze function of Monitoring and Control subsystem which is a part of GNSS Ground Station. We propose Monitoring and Control subsystem which contains the navigation software for GNSS Ground System to monitor and control equipments in GNSS Ground Station, to spread the applied field of navigation system, and to provide improved navigation information to user.

  17. The computerized management for individual monitoring data in Daya Bay Nuclear Power Station

    International Nuclear Information System (INIS)

    Lin Shumou; Yang Xiaochen

    1995-01-01

    The authors report the individual monitoring data management system (IDOSE) at Daya Bay Nuclear Power Station. The components of the individual monitoring system, the design requirements of IDOSE, the characteristics and application of this computerized management system are mainly presented. Its application shows that IDOSE meets the requirements of the concerning occupational standards of the state and matches with the requirements of IAEA/ISOE

  18. Sea level monitoring in Africa | Woodworth | African Journal of ...

    African Journals Online (AJOL)

    Information Network for Africa (ODINAfrica) programme are described and a survey of currently existing and planned sea level stations in Africa is presented, together with information on where data for existing stations may be found. Keywords: sea level data applications, sea level data telemetry, sea level networks. African ...

  19. Technical memorandum - Aamjiwnaang First Nation community air monitoring station - results for September 2008 to August 2009

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-01-15

    In 2008, the provincial and federal governments, working with the Aamjiwnaang First Nation, established the Aamjiwnaang First Nation community air monitoring station. The station's purpose was to monitor a series of contaminants produced by local industry. In addition, through the collection and analysis of air quality information, the station provided useful input to air quality studies and community health assessments. This report presents the results from analysis of air quality information between September 1, 2008 and August 31, 2009. Overall the report finds that the local air quality is similar to that in surrounding communities during this period and there were no exceedances of any ministry standard or guideline recorded concerning the expectations for particulate matter and ozone. It will be possible in the future to use this air quality information for comparison and correlation with known point sources or modeled results.

  20. 40 CFR 52.430 - Photochemical Assessment Monitoring Stations (PAMS) Program.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Photochemical Assessment Monitoring Stations (PAMS) Program. 52.430 Section 52.430 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Natural Resources & Environmental Control submitted a plan for the establishment and implementation of a...

  1. Radioactivity in the vicinity of Sizewell nuclear power station: marine environmental monitoring, 1983

    International Nuclear Information System (INIS)

    Hunt, G.J.

    1984-01-01

    Regular monitoring of radioactivity in the aquatic environment of the British Isles has continued. A report presents the results of this program in relation to the Sizewell nuclear power station for 1983, so as to supplement the most recently available full report which is for 1982. (author)

  2. 40 CFR 52.480 - Photochemical Assessment Monitoring Stations (PAMS) Program.

    Science.gov (United States)

    2010-07-01

    ... of Columbia's Department of Consumer and Regulatory Affairs submitted a plan for the establishment... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Photochemical Assessment Monitoring Stations (PAMS) Program. 52.480 Section 52.480 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...

  3. Background compensation for a radiation level monitor

    Science.gov (United States)

    Keefe, D.J.

    1975-12-01

    Background compensation in a device such as a hand and foot monitor is provided by digital means using a scaler. With no radiation level test initiated, a scaler is down-counted from zero according to the background measured. With a radiation level test initiated, the scaler is up-counted from the previous down-count position according to the radiation emitted from the monitored object and an alarm is generated if, with the scaler having crossed zero in the positive going direction, a particular number is exceeded in a specific time period after initiation of the test. If the test is initiated while the scale is down-counting, the background count from the previous down- count stored in a memory is used as the initial starting point for the up-count.

  4. High system-safety level of nuclear power stations

    International Nuclear Information System (INIS)

    Lutz, H.R.

    1976-01-01

    A bluntly worded disquisition contrasting the incidence of death and harm to persons in the chemical industry with the low hazards in nuclear power stations. Quotes conclusions from a U.S. accident study that the risk from 100 large power stations is 100 times smaller than from chlorine manufacture and transport. The enclosure of a reactor in a safety container, the well understood effects of radioactivity on man, and the ease of measuring leakage well below safe limits, are safety features which he considers were not matched in the products and plant of the Seveso factory which suffered disaster. Questions the usefulness of warnings about nuclear dangers when chemical dangers are much greater and road dangers very much greater still. (R.W.S.)

  5. Transformation of Air Quality Monitor Data from the International Space Station into Toxicological Effect Groups

    Science.gov (United States)

    James, John T.; Zalesak, Selina M.

    2011-01-01

    The primary reason for monitoring air quality aboard the International Space Station (ISS) is to determine whether air pollutants have collectively reached a concentration where the crew could experience adverse health effects. These effects could be near-real-time (e.g. headache, respiratory irritation) or occur late in the mission or even years later (e.g. cancer, liver toxicity). Secondary purposes for monitoring include discovery that a potentially harmful compound has leaked into the atmosphere or that air revitalization system performance has diminished. Typical ISS atmospheric trace pollutants consist of alcohols, aldehydes, aromatic compounds, halo-carbons, siloxanes, and silanols. Rarely, sulfur-containing compounds and alkanes are found at trace levels. Spacecraft Maximum Allowable Concentrations (SMACs) have been set in cooperation with a subcommittee of the National Research Council Committee on Toxicology. For each compound and time of exposure, the limiting adverse effect(s) has been identified. By factoring the analytical data from the Air Quality Monitor (AQM), which is in use as a prototype instrument aboard the ISS, through the array of compounds and SMACs, the risk of 16 specific adverse effects can be estimated. Within each adverse-effect group, we have used an additive model proportioned to each applicable 180-day SMAC to estimate risk. In the recent past this conversion has been performed using archival data, which can be delayed for months after an air sample is taken because it must be returned to earth for analysis. But with the AQM gathering in situ data each week, NASA is in a position to follow toxic-effect groups and correlate these with any reported crew symptoms. The AQM data are supplemented with data from real-time CO2 instruments aboard the ISS and from archival measurements of formaldehyde, which the AQM cannot detect.

  6. Automated high-volume aerosol sampling station for environmental radiation monitoring

    International Nuclear Information System (INIS)

    Toivonen, H.; Honkamaa, T.; Ilander, T.; Leppaenen, A.; Nikkinen, M.; Poellaenen, R.; Ylaetalo, S.

    1998-07-01

    An automated high-volume aerosol sampling station, known as CINDERELLA.STUK, for environmental radiation monitoring has been developed by the Radiation and Nuclear Safety Authority (STUK), Finland. The sample is collected on a glass fibre filter (attached into a cassette), the airflow through the filter is 800 m 3 /h at maximum. During the sampling, the filter is continuously monitored with Na(I) scintillation detectors. After the sampling, the large filter is automatically cut into 15 pieces that form a small sample and after ageing, the pile of filter pieces is moved onto an HPGe detector. These actions are performed automatically by a robot. The system is operated at a duty cycle of 1 d sampling, 1 d decay and 1 d counting. Minimum detectable concentrations of radionuclides in air are typically 1Ae10 x 10 -6 Bq/m 3 . The station is equipped with various sensors to reveal unauthorized admittance. These sensors can be monitored remotely in real time via Internet or telephone lines. The processes and operation of the station are monitored and partly controlled by computer. The present approach fulfils the requirements of CTBTO for aerosol monitoring. The concept suits well for nuclear material safeguards, too

  7. Retrofitting of an improved stack monitoring system in Rajasthan atomic power station

    International Nuclear Information System (INIS)

    Natarajan, K.

    1985-01-01

    The problems encountered in the measurement of inert gas activities, iodine activity and tritium activity released through the stack in RAPS are described and the considerations for the development of improved instruments outlined. The new approach provides for better accuracy of measurement of all the relevant radioactive parameters in the stack at one centralised place. The construction work in the station for the newly conceived stack activity monitoring system is completed and the earlier equipment used is installed in the room temporarily. Development prototypes of stack inert gas monitoring system and iodine monitoring system as described in Section 5 are made and evaluated. Fabrication of new equipment for retrofitting in RAPS is in progress and these will replace the equipment temporarily installed in the station

  8. Optimum Layout for Water Quality Monitoring Stations through Ant Colony Algorithm

    Directory of Open Access Journals (Sweden)

    Amin Afshar

    2006-09-01

    Full Text Available Due to the high cost of monitoring systems, budget limitations, and high priority given to water quality control in municipal networks, especially for unexpected events, optimum location of monitoring stations has received considerable attention during the last decade. An optimization model needs to be developed for the desirable location of monitoring stations. This research attempts to develop such a model using Ant Colony Optimization (ACO algorithm and tires to verify it through a bench-mark classical example used in previous researches. Selection of ACO as optimizer was fully justified due to discrete decision space and extensive number of binary variables in modeling system. Diversity of the policies derived from ACO may facilitate the process of decision making considering the social, physical, and economical conditions.

  9. COLLABORATIVE MULTI-LEVEL PLAN MONITORING

    Directory of Open Access Journals (Sweden)

    Mohamad K. ALLOUCHE

    2011-01-01

    Full Text Available The recent worldwide connectivity and the net-centricity of military operations (coalition-based operations are witnessing an increasing need for the monitoring of plan execution for enhanced resource management and decision making. Monitoring of ongoing operations is the process of continuous observation recording and reporting. In this process the plan becomes a resource that needs to be managed effi ciently. The centralized approach to plan monitoring soon reaches its limits when plan execution is distributed across different organizations/countries. We propose a new framework that would allow different monitoring nodes distributed across the network. An effi cient propagation mechanism that allows information exchange between the different nodes would also be needed. The main purpose of this mechanism is to present the right information, to the right person, at the right time. To cope with a rapid increase of information fl ow through the network, an effi cient alarm management mechanism allows the presentation of the information with an appropriate level of details.

  10. Environmental Radiation Surveillance Results from over the Last Decade of Operational Experience at the Regional Radiation Monitoring Stations(RRMS)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hae Young [Daegu Regional Radiation Monitoring Station, Daegu (Korea, Republic of); Yoo, Dong Han [Ulsan Regional Radiation Monitoring Station, Ulsan (Korea, Republic of); Lee, Sang Hoon [Kyungpook National University, Daegu (Korea, Republic of)

    2015-10-15

    The objectives of the current program are to monitor environmental radiation/radioactivity level in Korea and to provide the base-line data on environmental radiation/radioactivity which will be useful in the case of radiological emergency situations. This program plays an important role in the view of protecting the public health against the potential hazards of radiation and maintaining a clean environment. This paper describes an introduction to the Regional Radiation Monitoring Stations (RRMS), and also presents some results of recent years (2001-2014). The environmental radiation surveillance results of years 2001-2014 have been described. It indicates normal levels of radiation in the past years. These kinds of studies are very important in providing references in understanding the environmental radioactivity level in a particular region.

  11. Monitoring and studies of environmental cumulative dose of Guangdong Da Ya Bay nuclear-power station by thermoluminescent dosimetry

    International Nuclear Information System (INIS)

    Wan Yusong; Li Shili; Yang Lin; Feng Zhanglin; Kong Lingfeng; Yu Jinglan

    1999-01-01

    The author presents the environmental γ radiation routine monitoring by TLD in Guangdong Da Ya Bay Nuclear Power Station and its peripheral 50 km area, which has been put into commercial operation since 1994. The year's monitoring result indicates that there is no obvious change of the total environmental γ radiation in Da Ya Bay Nuclear Power Station and its peripheral 50 km area. But the influence of gas release γ radiation was monitored in 1995 at the monitoring points in the area of 0∼1 km from the nuclear power station

  12. Report on radioactive discharges and environmental monitoring at nuclear power stations during 1991

    International Nuclear Information System (INIS)

    Hurst, M.J.; Thomas, D.W.

    1992-09-01

    This report presents the details for 1991 of radioactive discharges and environmental monitoring at Nuclear Electric sites. In addition to the main section which summarises the discharges and monitoring at the Company's nuclear sites as a whole, appendices are presented covering the data in detail for individual sites. In each case the radiological impact on the general public has been estimated. Discharges generally were not substantially different from those of recent years. All radioactive effluent discharges from power stations were within authorised limits. Radiation doses to members of the public resulting from these discharges, and from direct radiation from the Stations, were in all cases less than the limit of 1 mSv per year which has been recommended by ICRP since 1985. (Author)

  13. Level 1 Electric Vehicle Charging Stations at the Workplace

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Margaret [Energetics Incorporated, Columbia, MD (United States)

    2016-07-29

    Level 1 charging (110-120 V) can be a good fit for many workplace charging programs. This document highlights the experiences of a selection of Workplace Charging Challenge partners that use Level 1 charging.

  14. Indicators for monitoring of safety operation and condition of nuclear power stations

    International Nuclear Information System (INIS)

    Manova, D.

    2001-01-01

    A common goal of all employees in the nuclear power field is safety operation of nuclear power stations. The evaluation and control of NPP safety operation are a part of the elements of safety management. The present report is related only to a part of the total assessment and control of the plant safety operation, namely - the indicator system for monitoring of Kozloduy NPP operation and condition. (author)

  15. Position monitor of SR beam on XAFS experimental station in BSRF

    International Nuclear Information System (INIS)

    Chen Xianneng; Xie Yaning; Hu Tiandou; Jin Yalan; Huang Daxian

    1995-01-01

    A monitor of density and position of SR (Synchrotron Radiation) beam is built on XAFS (X-ray Absorption Fine Structure) experimental station in BSRF (Beijing Synchrotron Radiation Facility). It is composed of the beam slit and its drivers, weak current amplifiers, computing amplifier for coordinate of the beam position and display with RS-232 interface. The equipment can be used for other measurement fields related with current and voltage

  16. Welding station condition monitoring using bluetooth enabled sensors and intelligent data management

    Energy Technology Data Exchange (ETDEWEB)

    Eyers, D R; Grosvenor, R I; Prickett, P W [Intelligent Process Monitoring and Management (IPMM) Group, Cardiff School of Engineering, Cardiff University, Wales (United Kingdom)

    2005-01-01

    This paper reports on the first phase deployment of bluetooth enabled condition monitoring systems at a large multinational engineering company. The radio networking of sensor signals is a fast developing area and the facilities afforded by the Wisnet device were used in the monitoring of a welding station. This and any of the planned further monitoring systems had to comply to a carefully managed IT information plan at the company. For the example application, the development and testing of microcontoller-based pre-processing of data is reported. This includes further development of the Petri Net approach to provide event-based monitoring as a sensible alternative to the continuous transmission of the sensory data.

  17. Remote Working Level Monitor. Final report

    International Nuclear Information System (INIS)

    1977-01-01

    The Remote Working Level Monitor (RWLM) is an instrument used to remotely monitor the RN-daughter concentrations and the Working Level (WL). It is an ac powered, microprocessor based instrument which multiplexes two independent detector units to a single central processor unit (CPU). The CPU controls the actuation of the detector units and processes and outputs the data received from these remote detector units. The remote detector units are fully automated and require no manual operation once they are set up. They detect and separate the alpha emitters of RaA and RaC' as well as detecting the beta emitters of RaB and RaC. The resultant pulses from these detected radioisotopes are transmitted to the CPU for processing. The programmed microprocessor performs the mathematical manipulations necessary to output accurate Rn-daughter concentrations and the WL. A special subroutine within the program enables the RWLM to run and output a calibration procedure on command. The data resulting from this request can then be processed in a separate program on most computers capable of BASIC programming. The calibration program results in the derivation of coefficients and beta efficiencies which provides calibrated coefficients and beta efficiencies

  18. Environmental wodking level monitor. Final report

    International Nuclear Information System (INIS)

    Keefe, D; McDowell, W.P.; Groer, P.G.

    1978-01-01

    The Environmental Working Level Monitor (EWLM) is an instrument used to automatically monitor airborne Rn-daughter concentrations and the Working Level (WL). It is an ac powered, microprocessor--based instrument with an external inverter provided for dc operation if desired. The microprocessor's control processor unit (CPU) controls the actuation of the detector assembly and processes its output signals to yield the measurements in the proper units. The detectors are fully automated and require no manual operations once the instrument is programmed. They detect and separate the alpha emitters of RaA and RaC' as well as detecting the beta emitters of RaB and RaC. The resultant pulses from these detected radioisotopes are transmitted to the CPU. The programmed microprocessor performs the mathematical manipulations necessary to output accurate Rn-daughter concentrations and the WL. A special subroutine within the system program enables the EWLM to run a calibration procedure on command which yields calibration data. This data can then be processed in a separate program on most computers capable of BASIC programming. This calibration program results in the derivation of coefficients and beta efficiencies which provides the calibrated coefficients and beta efficiencies required by the main system program to assure proper calibration of the individual EWLM's

  19. High-Speed Monitoring of Multiple Grid-Connected Photovoltaic Array Configurations and Supplementary Weather Station.

    Science.gov (United States)

    Boyd, Matthew T

    2017-06-01

    Three grid-connected monocrystalline silicon photovoltaic arrays have been instrumented with research-grade sensors on the Gaithersburg, MD campus of the National Institute of Standards and Technology (NIST). These arrays range from 73 kW to 271 kW and have different tilts, orientations, and configurations. Irradiance, temperature, wind, and electrical measurements at the arrays are recorded, and images are taken of the arrays to monitor shading and capture any anomalies. A weather station has also been constructed that includes research-grade instrumentation to measure all standard meteorological quantities plus additional solar irradiance spectral bands, full spectrum curves, and directional components using multiple irradiance sensor technologies. Reference photovoltaic (PV) modules are also monitored to provide comprehensive baseline measurements for the PV arrays. Images of the whole sky are captured, along with images of the instrumentation and reference modules to document any obstructions or anomalies. Nearly, all measurements at the arrays and weather station are sampled and saved every 1s, with monitoring having started on Aug. 1, 2014. This report describes the instrumentation approach used to monitor the performance of these photovoltaic systems, measure the meteorological quantities, and acquire the images for use in PV performance and weather monitoring and computer model validation.

  20. A design proposal of real-time monitoring stations: implementation and performance in contrasting environmental conditions

    Directory of Open Access Journals (Sweden)

    Jose González

    2012-09-01

    Full Text Available With the aim of creating a real-time monitoring network for both oceanographic and meteorological data, a monitoring station conceptual design was developed. A common framework for software and electronics was adapted to different environmental conditions using two buoy approaches: one intended for oceanic waters, to be moored up to 30-40 m depth, where waves are the critical design factor, and one for continental waters (rivers, lakes and the inner part of estuaries, where currents are the critical design factor. When structures such as bridges are present in the area, the monitoring station can be installed on these structures, thus reducing its impact and increasing safety. In this paper, the design, implementation, operation and performance of these stations are described. A reliability index is calculated for the longest time series of the three related deployment options on the Galician coast: Cíes (oceanic buoy in front of the Ría de Vigo, Catoira (continental buoy in the Ulla river and Cortegada (installation in a bed in the Ría de Arousa.

  1. GNSS-Reflectometry based water level monitoring

    Science.gov (United States)

    Beckheinrich, Jamila; Schön, Steffen; Beyerle, Georg; Apel, Heiko; Semmling, Maximilian; Wickert, Jens

    2013-04-01

    Due to climate changing conditions severe changes in the Mekong delta in Vietnam have been recorded in the last years. The goal of the German Vietnamese WISDOM (Water-related Information system for the Sustainable Development Of the Mekong Delta) project is to build an information system to support and assist the decision makers, planners and authorities for an optimized water and land management. One of WISDOM's tasks is the flood monitoring of the Mekong delta. Earth reflected L-band signals from the Global Navigation Satellite System show a high reflectivity on water and ice surfaces or on wet soil so that GNSS-Reflectometry (GNSS-R) could contribute to monitor the water level in the main streams of the Mekong delta complementary to already existing monitoring networks. In principle, two different GNSS-R methods exist: the code- and the phase-based one. As the latter being more accurate, a new generation of GORS (GNSS Occultation, Reflectometry and Scatterometry) JAVAD DELTA GNSS receiver has been developed with the aim to extract precise phase observations. In a two week lasting measurement campaign, the receiver has been tested and several reflection events at the 150-200 m wide Can Tho river in Vietnam have been recorded. To analyze the geometrical impact on the quantity and quality of the reflection traces two different antennas height were tested. To track separately the direct and the reflected signal, two antennas were used. To derive an average height of the water level, for a 15 min observation interval, a phase model has been developed. Combined with the coherent observations, the minimum slope has been calculated based on the Least- Squares method. As cycle slips and outliers will impair the results, a preprocessing of the data has been performed. A cycle slip detection strategy that allows for automatic detection, identification and correction is proposed. To identify outliers, the data snooping method developed by Baarda 1968 is used. In this

  2. Base Station Performance Model

    OpenAIRE

    Walsh, Barbara; Farrell, Ronan

    2005-01-01

    At present the testing of power amplifiers within base station transmitters is limited to testing at component level as opposed to testing at the system level. While the detection of catastrophic failure is possible, that of performance degradation is not. This paper proposes a base station model with respect to transmitter output power with the aim of introducing system level monitoring of the power amplifier behaviour within the base station. Our model reflects the expe...

  3. Measurement of Deformations by MEMS Arrays, Verified at Sub-millimetre Level Using Robotic Total Stations

    Directory of Open Access Journals (Sweden)

    Tomas Beran

    2014-06-01

    Full Text Available Measurement of sub-millimetre-level deformations of structures in the presence of ambienttemperature changes can be challenging. This paper describes the measurement of astructure moving due to temperature changes, using two ShapeAccelArray (SAAinstruments, and verified by a geodetic monitoring system. SAA is a geotechnicalinstrument often used for monitoring of displacements in soil. SAA uses micro-electro-mechanical system (MEMS sensors to measure tilt in the gravity field. The geodeticmonitoring system, which uses ALERT software, senses the displacements of targetsrelative to control points, using a robotic total station (RTS. The test setup consists of acentral four-metre free-standing steel tube with other steel tubes welded to most of itslength. The central tube is anchored in a concrete foundation. This composite “pole” isequipped with two SAAs as well as three geodetic prisms mounted on the top, in the middle,and in the foundation. The geodetic system uses multiple control targets mounted inconcrete foundations of nearby buildings, and at the base of the pole. Long-termobservations using two SAAs indicate that the pole is subject to deformations due to cyclicalambient temperature variations causing the pole to move by a few millimetres each day. Ina multiple-day experiment, it was possible to track this movement using SAA as well as theRTS system. This paper presents data comparing the measurements of the two instrumentsand provides a good example of the detection of two-dimensional movements of seeminglyrigid objects due to temperature changes.

  4. Long-term monitoring of persistent organic pollutants (POPs) at the Norwegian Troll station in Dronning Maud Land, Antarctica

    Science.gov (United States)

    Kallenborn, R.; Breivik, K.; Eckhardt, S.; Lunder, C. R.; Manø, S.; Schlabach, M.; Stohl, A.

    2013-07-01

    A first long-term monitoring of selected persistent organic pollutants (POPs) in Antarctic air has been conducted at the Norwegian research station Troll (Dronning Maud Land). As target contaminants 32 PCB congeners, α- and γ-hexachlorocyclohexane (HCH), trans- and cis-chlordane, trans- and cis-nonachlor, p,p'- and o,p-DDT, DDD, DDE as well as hexachlorobenzene (HCB) were selected. The monitoring program with weekly samples taken during the period 2007-2010 was coordinated with the parallel program at the Norwegian Arctic monitoring site (Zeppelin mountain, Ny-Ålesund, Svalbard) in terms of priority compounds, sampling schedule as well as analytical methods. The POP concentration levels found in Antarctica were considerably lower than Arctic atmospheric background concentrations. Similar to observations for Arctic samples, HCB is the predominant POP compound, with levels of around 22 pg m-3 throughout the entire monitoring period. In general, the following concentration distribution was found for the Troll samples analyzed: HCB > Sum HCH > Sum PCB > Sum DDT > Sum chlordanes. Atmospheric long-range transport was identified as a major contamination source for POPs in Antarctic environments. Several long-range transport events with elevated levels of pesticides and/or compounds with industrial sources were identified based on retroplume calculations with a Lagrangian particle dispersion model (FLEXPART).

  5. Long-term monitoring of persistent organic pollutants (POPs at the Norwegian Troll station in Dronning Maud Land, Antarctica

    Directory of Open Access Journals (Sweden)

    R. Kallenborn

    2013-07-01

    Full Text Available A first long-term monitoring of selected persistent organic pollutants (POPs in Antarctic air has been conducted at the Norwegian research station Troll (Dronning Maud Land. As target contaminants 32 PCB congeners, α- and γ-hexachlorocyclohexane (HCH, trans- and cis-chlordane, trans- and cis-nonachlor, p,p'- and o,p-DDT, DDD, DDE as well as hexachlorobenzene (HCB were selected. The monitoring program with weekly samples taken during the period 2007–2010 was coordinated with the parallel program at the Norwegian Arctic monitoring site (Zeppelin mountain, Ny-Ålesund, Svalbard in terms of priority compounds, sampling schedule as well as analytical methods. The POP concentration levels found in Antarctica were considerably lower than Arctic atmospheric background concentrations. Similar to observations for Arctic samples, HCB is the predominant POP compound, with levels of around 22 pg m−3 throughout the entire monitoring period. In general, the following concentration distribution was found for the Troll samples analyzed: HCB > Sum HCH > Sum PCB > Sum DDT > Sum chlordanes. Atmospheric long-range transport was identified as a major contamination source for POPs in Antarctic environments. Several long-range transport events with elevated levels of pesticides and/or compounds with industrial sources were identified based on retroplume calculations with a Lagrangian particle dispersion model (FLEXPART.

  6. Validation of moderator-level reactivity coefficient using station data

    Energy Technology Data Exchange (ETDEWEB)

    Younis, M.; Martchouk, I., E-mail: mohamed.younis@amecfw.com, E-mail: iouri.martchouk@amecfw.com [Amec Foster Wheeler, Toronto, ON (Canada); Buchan, P.D., E-mail: david.buchan@opg.com [Ontario Power Generation, Pickering, ON (Canada)

    2015-07-01

    The reactivity effect due to variations in the moderator level has been recognized as a reactor physics phenomenon of importance during normal operation and accident analysis. The moderator-level reactivity coefficient is an important parameter in safety analysis of CANDU reactors, e.g., during Loss of Moderator Heat Sink as well as in the simulation of Reactor Regulating System action in CANDU reactors that use moderator level for reactivity control. This paper presents the results of the validation exercise of the reactor-physics toolset using the measurements performed in Pickering Unit 4 in 2003. The capability of the code suite of predicting moderator-level reactivity effect was tested by comparing measured and predicted reactor-physics parameters. (author)

  7. Water shortage and drought monitoring in Bačka region (Vojvodina, North Serbia: Setting-up measurement stations network

    Directory of Open Access Journals (Sweden)

    Jovanović Mlađen

    2013-01-01

    Full Text Available Water shortage and drought, as the most important hydro-climatic hazards, cause significant damages in case of most continents including SE Europe. An experimental field established in Bačka region (Vojvodina Autonomous Province, North Serbia for the purpose of droughts/water shortage monitoring and remote sensing under ongoing IPA project 'Water shortage hazard and adaptive water management strategies in the Hungarian-Serbian cross-border region' (WAHASTRAT. The main objective of this project is to determine water shortage con­flicts on a local and regional level, and to reveal the frequency, extent and severity of future hydro-cli­matic hazards. The locations of eight measurement stations selected on the principle of representativeness in term of terrain configuration and soil cover. An area in which measurement stations were placed, covers about 1000 km2 (12% of total area of Bačka and includes geomorphic units which reliable represent the relief of the whole Bačka region. Measurement stations were placed on 4 out of 5 most common soil types in the Bačka and Vojvodina: chernozem, alluvial soils, smonitza and saline and alkali soils. A measurement equipment system was constructed for the requirements of the WAHASTRAT project. The aim was to design a user-friendly and affordable IT solution, which would enable continuous re­mote monitoring of meteorological parameters and soil moisture. Independent solar-powered meas­urement stations are able to automatically measure air temperature, air humidity, wind speed, wind di­rection, precipitation and soil moisture.

  8. Statistical modelling of monthly mean sea level at coastal tide gauge stations along the Indian subcontinent

    Digital Repository Service at National Institute of Oceanography (India)

    Srinivas, K.; Das, V.K.; DineshKumar, P.K.

    This study investigates the suitability of statistical models for their predictive potential for the monthly mean sea level at different stations along the west and east coasts of the Indian subcontinent. Statistical modelling of the monthly mean...

  9. Design and implementation of data acquisition, communication and monitoring system for photovoltaic power station in microgrid

    Energy Technology Data Exchange (ETDEWEB)

    Deng, Wei; Pei, Wei; Qi, Zhiping; Kong, Li [Institute of Electrical Engineering, CAS, Beijing (China)

    2008-07-01

    This paper presents the design and realization of data acquisition, communication and monitoring system for photovoltaic power station. The data acquisition module including filter algorithm and signal modulation circuit uses the digital signal processor (DSP) as the main processor, it can realize accurate real-time data acquisition; The data communication module uses Ethernet as communication network between PV system and MicroGrid. The gateway using ARM microprocessor can realize protocol conversion and bidirectional communication between CAN Bus and Ethernet; The monitoring unit with friendly human-machine interface keeps real-time performance monitoring of PV system to realize automation control. The results of experiment show that the system is practicable and effective. (orig.)

  10. ANITA Air Monitoring on the International Space Station: Results Compared to Other Measurements

    Science.gov (United States)

    Honne, A.; Schumann-Olsen, H.; Kaspersen, K.; Limero, T.; Macatangay, A.; Mosebach, H.; Kampf, D.; Mudgett, P. D.; James, J. T.; Tan, G.; hide

    2009-01-01

    ANITA (Analysing Interferometer for Ambient Air) is a flight experiment precursor for a permanent continuous air quality monitoring system on the ISS (International Space Station). For the safety of the crew, ANITA can detect and quantify quasi-online and simultaneously 33 gas compounds in the air with ppm or sub-ppm detection limits. The autonomous measurement system is based on FTIR (Fourier Transform Infra-Red spectroscopy). The system represents a versatile air quality monitor, allowing for the first time the detection and monitoring of trace gas dynamics in a spacecraft atmosphere. ANITA operated on the ISS from September 2007 to August 2008. This paper summarizes the results of ANITA s air analyses with emphasis on comparisons to other measurements. The main basis of comparison is NASA s set of grab samples taken onboard the ISS and analysed on ground applying various GC-based (Gas Chromatography) systems.

  11. Recent developments in water quality monitoring for Space Station reclaimed wastewaters

    Science.gov (United States)

    Small, John W.; Verostko, Charles E.; Linton, Arthur T.; Burchett, Ray

    1987-01-01

    This paper discusses the recent developments in water quality monitoring for Space Station reclaimed wastewaters. A preprototype unit that contains an ultraviolet absorbance organic carbon monitor integrated with pH and conductivity sensors is presented. The preprototype has provisions for automated operation and is a reagentless flow-through system without any gas/liquid interfaces. The organic carbon monitor detects by utraviolet absorbance the organic impurities in reclaimed wastewater which may be correlated to the organic carbon content of the water. A comparison of the preprototype organic carbon detection values with actual total organic carbon measurements is presented. The electrolyte double junction concept for the pH sensor and fixed electrodes for both the pH and conductivity sensors are discussed. In addition, the development of a reagentless organic carbon analyzer that incorporates ultraviolet oxidation and infrared detection is presented. Detection sensitivities, hardware development, and operation are included.

  12. Mini neutron monitor measurements at the Neumayer III station and on the German research vessel Polarstern

    Science.gov (United States)

    Heber, B.; Galsdorf, D.; Herbst, K.; Gieseler, J.; Labrenz, J.; Schwerdt, C.; Walter, M.; Benadé, G.; Fuchs, R.; Krüger, H.; Moraal, H.

    2015-08-01

    Neutron monitors (NMs) are ground-based devices to measure the variation of cosmic ray intensities, and although being reliable they have two disadvantages: their size as well as their weight. As consequence, [1] suggested the development of a portable, and thus much smaller and lighter, calibration neutron monitor that can be carried to any existing station around the world [see 2; 3]. But this mini neutron monitor, moreover, can also be installed as an autonomous station at any location that provides ’’office” conditions such as a) temperatures within the range of around 0 to less than 40 degree C as well as b) internet and c) power supply. However, the best location is when the material above the NM is minimized. In 2011 a mini Neutron Monitor was installed at the Neumayer III station in Antarctica as well as the German research vessel Polarstern, providing scientific data since January 2014 and October 2012, respectively. The Polarstern, which is in the possession of the Federal Republic of Germany represented by the Ministry of Education and Research and operated by the Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research and managed by the shipping company Laeisz, was specially designed for working in the polar seas and is currently one of the most sophisticated polar research vessels worldwide. It spends almost 310 days a year at sea usually being located in the waters of Antarctica between November and March while spending the northern summer months in Arctic waters. Therefore, the vessel scans the rigidity range below the atmospheric threshold and above 10 GV twice a year. In contrast to spacecraft measurements NM data are influenced by variations of the geomagnetic field as well as the atmospheric conditions. Thus, in order to interpret the data a detailed knowledge of the instrument sensitivity with geomagnetic latitude (rigidity) and atmospheric pressure is essential. In order to determine the atmospheric response data from the

  13. Mini neutron monitor measurements at the Neumayer III station and on the German research vessel Polarstern

    International Nuclear Information System (INIS)

    Heber, B; Galsdorf, D; Herbst, K; Gieseler, J; Labrenz, J; Schwerdt, C; Walter, M; Benadé, G; Fuchs, R; Krüger, H; Moraal, H

    2015-01-01

    Neutron monitors (NMs) are ground-based devices to measure the variation of cosmic ray intensities, and although being reliable they have two disadvantages: their size as well as their weight. As consequence, [1] suggested the development of a portable, and thus much smaller and lighter, calibration neutron monitor that can be carried to any existing station around the world [see 2; 3]. But this mini neutron monitor, moreover, can also be installed as an autonomous station at any location that provides ’’office” conditions such as a) temperatures within the range of around 0 to less than 40 degree C as well as b) internet and c) power supply. However, the best location is when the material above the NM is minimized. In 2011 a mini Neutron Monitor was installed at the Neumayer III station in Antarctica as well as the German research vessel Polarstern, providing scientific data since January 2014 and October 2012, respectively. The Polarstern, which is in the possession of the Federal Republic of Germany represented by the Ministry of Education and Research and operated by the Alfred Wegener Institute, Helmholtz Centre for Polar and Marine Research and managed by the shipping company Laeisz, was specially designed for working in the polar seas and is currently one of the most sophisticated polar research vessels worldwide. It spends almost 310 days a year at sea usually being located in the waters of Antarctica between November and March while spending the northern summer months in Arctic waters. Therefore, the vessel scans the rigidity range below the atmospheric threshold and above 10 GV twice a year. In contrast to spacecraft measurements NM data are influenced by variations of the geomagnetic field as well as the atmospheric conditions. Thus, in order to interpret the data a detailed knowledge of the instrument sensitivity with geomagnetic latitude (rigidity) and atmospheric pressure is essential. In order to determine the atmospheric response data from the

  14. Microseismic monitoring of columnar jointed basalt fracture activity: a trial at the Baihetan Hydropower Station, China

    Science.gov (United States)

    Chen, Bing-Rui; Li, Qing-Peng; Feng, Xia-Ting; Xiao, Ya-Xun; Feng, Guang-Liang; Hu, Lian-Xing

    2014-10-01

    Severe stress release has occurred to the surrounding rocks of the typically columnar jointed basalt after excavation at the Baihetan Hydropower Station, Jinsha River, China, where cracking, collapse, and other types of failure may take place occasionally due to relaxation fracture. In order to understand the relaxation fracture characteristics of the columnar jointed basalt in the entire excavation process at the diversion tunnel of the Baihetan Hydropower Station, real-time microseismic monitoring tests were performed. First, the applicability of a geophone and accelerometer was analyzed in the columnar jointed basalt tunnel, and the results show that the accelerometer was more applicable to the cracking monitoring of the columnar jointed basalt. Next, the waveform characteristics of the microseismic signals were analyzed, and the microseismic signals were identified as follows: rock fracture signal, drilling signal, electrical signal, heavy vehicle passing signal, and blast signal. Then, the attenuation characteristics of the microseismic signals in the columnar jointed basalt tunnel were studied, as well as the types and characteristics of the columnar jointed basalt fracture. Finally, location analysis was conducted on the strong rock fracture events, in which four or more sensors were triggered, to obtain the temporal and spatial evolution characteristics and laws of the columnar jointed basalt relaxation fracture after excavation. The test results are not only of important reference value to the excavation and support of diversion tunnel at the Baihetan Hydropower Station, but also of great referential significance and value to the conduction of similar tests.

  15. Survey of RF exposure levels from mobile telephone base stations in Australia.

    Science.gov (United States)

    Henderson, S I; Bangay, M J

    2006-01-01

    This paper reports the results of an exposure level survey of radiofrequency electromagnetic energy originating from mobile telephone base station antennas. Measurements of CDMA800, GSM900, GSM1800, and 3G(UMTS) signals were performed at distances ranging over 50 to 500 m from 60 base stations in five Australian cities. The exposure levels from these mobile telecommunications base stations were found to be well below the general public exposure limits of the ICNIRP guidelines and the Australian radiofrequency standard (ARPANSA RPS3). The highest recorded level from a single base station was 7.8 x 10(-3) W/m(2), which translates to 0.2% of the general public exposure limit.

  16. Analysis of the thermal monitoring data collected at the Peach Bottom Atomic Power Station

    International Nuclear Information System (INIS)

    Witten, A.J.; Gray, D.D.

    1977-01-01

    A comprehensive study of the data collected as part of the environmental technical specifications program for Units 2 and 3 of the Peach Bottom Atomic Power Station was conducted for the Office of Nuclear Regulatory Research of the U.S. Nuclear Regulatory Commission. The study included an analysis of both the hydrothermal and ecological data collected from 1967 through 1976. This paper presents the details of the hydrothermal analysis performed under this program. The two primary methods used for temperature monitoring, during both the preoperational and operational periods of the program, are a fixed thermograph network and boat survey measurements. Analysis of the boat survey data provides a fine resolution demonstrating variations in ambient temperature in Conowingo Pond, as well as providing a qualitative picture of the thermal plume produced by the Peach Bottom thermal discharge. The data from 18 thermograph stations was used for a quantitative probability analysis

  17. 13th Workshop on Radiation Monitoring for the International Space Station - Final Program

    International Nuclear Information System (INIS)

    2008-01-01

    The Workshop on Radiation Monitoring for the International Space Station (WRMISS) has been held annually since 1996. The major purpose of WRMISS is to provide a forum for discussion of technical issues concerning radiation dosimetry aboard the International Space Station. This includes discussion of new results, improved instrumentation, detector calibration, and radiation environment and transport models. The goal of WRMISS is to enhance international efforts to provide the best information on the space radiation environment in low-Earth orbit and on the exposure of astronauts and cosmonauts in order to optimize the radiation safety of the ISS crew. During the 13 th Annual WRMISS, held in the Institute of Nuclear Physics (Krakow, Poland) on 8-10 September 2008, participants presented 47 lectures

  18. Geo-enviromental monitoring system of the oil storages on petrol stations

    Directory of Open Access Journals (Sweden)

    Shimenkova Anastasiya Anatol'evna

    2014-03-01

    Full Text Available In large cities, fuel consumption is growing rapidly, and therefore the number of filling stations. And they are a source of anthropogenic impact on the environment and represent current scientific and practical task, because recently no research was conducted into the optimization of monitoring systems in the construction of gas station storage tanks, and no activity on replacing the obsolete design with new storage tanks. In this regard, much attention should be paid to the creation of geo-environmental systems integrated assessment of the environment, as well as modeling and forecasting various negative situations. In the modern world, the creation of such systems is possible with the help of modern computer tools such as geographic information systems.

  19. Linking cluster analysis with synoptic meteorology to characterise chemical climates at six north-west European monitoring stations

    Energy Technology Data Exchange (ETDEWEB)

    Dorling, S.R.; Davies, T.D. [Univ. of East Anglia, Norwich (United Kingdom)

    1994-12-31

    Synoptic scale atmospheric circulation patterns are often good surrogates for the transport pathway to an individual monitoring station. Davies et al. (1990) supported this idea by showing that the chemistry of precipitation samples collected at United Kingdom monitoring stations were strongly related to the Lamb weather type index, a daily classification of the synoptic circulation influencing United Kingdom weather. Such a classification does not, however, optimise the distinction between airflow from different directions and thus over different pollution source regions.

  20. Monitoring of external background radiation level in Asa dam ...

    African Journals Online (AJOL)

    An external background ionizing radiation study has been carried out within the Asa Dam Industrial Layout of Ilorin in Kwara State. The study was carried out in 5 stations within the industrial area using two Digilert Nuclear Radiation Monitors. The study has revealed that the external background ionizing radiation is ...

  1. On-line gamma spectroscopy measuring station for cover gas monitoring at KNK II

    International Nuclear Information System (INIS)

    Hoffmann, G.; Letz, K.D.

    1980-02-01

    An automated Ge-γ-spectrometer was developed for cover gas monitoring at KNK II which, by the gamma spectra measured, is to allow the following statements to be made on fuel cladding failure: Type, size, variation with time and subsequent development of the failure. In this report the hardware and software will be explained. Besides, an instruction manual was written for the measuring station, which allows to operate it without detailed knowledge of the manuals for the individual hardware components. (orig.) 891 HP/orig. 892 MKO [de

  2. The replacement gag vibration monitoring system for Hinkley Point 'B' power station

    International Nuclear Information System (INIS)

    Bagwell, T.; Morrish, M.F.G.

    1985-01-01

    The original computerised system for monitoring the vibration of gags in each reactor channel of the Hinkley Point 'B' AGR Power Station did not meet the specification for a more stringent safety requirement. This paper describes the replacement of that original single processor system with an enhanced dual processor/multiple scanner computer system used to satisfy this new safety and reliability need. The specification and installation of the new hardware and software are discussed, and some of the problems encountered and their solutions are highlighted. (author)

  3. A low cost micro-station to monitor soil water potential for irrigation management

    Science.gov (United States)

    Vannutelli, Edoardo; Masseroni, Daniele; Facchi, Arianna; Gandolfi, Claudio; Renga, Filippo

    2014-05-01

    The RISPArMiA project (which stands for "reduction of water wastage through the continuous monitoring of agri-environmental parameters") won in 2013 the contest called "LINFAS - The New Ideas Make Sustainable Agriculture" and sponsored by two Italian Foundations (Fondazione Italiana Accenture and Fondazione Collegio Università Milanesi). The objective of the RISPArMiA project is to improve the irrigation efficiency at the farm scale, by providing the farmer with a valuable decision support system for the management of irrigation through the use of low-cost sensors and technologies that can easily be interfaced with Mobile devices. Through the installation of tensiometric sensors within the cropped field, the soil water potential can be continuously monitored. Using open hardware electronic platforms, a data-logger for storing the measured data will be built. Data will be then processed through a software that will allow the conversion of the monitored information into an irrigation advice. This will be notified to the farmer if the measured soil water potential exceed literature crop-specific tensiometric thresholds. Through an extrapolation conducted on the most recent monitored data, it will be also possible to obtain a simple soil water potential prevision in absence of rain events. All the information will be sent directly to a virtual server and successively on the farmer Mobile devices. Each micro-station is completely autonomous from the energy point of view, since it is powered by batteries recharged by a solar panel. The transmission modulus consists of a GSM apparatus with a SIM card. The use of free platforms (Arduino) and low cost sensors (Watermark 200SS tensiometers and soil thermocouples) will significantly reduce the costs of construction of the micro-station which are expected to be considerably lower than those required for similar instruments on the market today . Six prototype micro-stations are actually under construction. Their field testing

  4. Exposure level and distribution characteristics of airborne bacteria and fungi in Seoul metropolitan subway stations.

    Science.gov (United States)

    Kim, Ki Youn; Kim, Yoon Shin; Kim, Daekeun; Kim, Hyeon Tae

    2011-01-01

    The exposure level and distribution characteristics of airborne bacteria and fungi were assessed in the workers' activity areas (station office, bedroom, ticket office and driver's seat) and passengers' activity areas (station precinct, inside the passenger carriage, and platform) of the Seoul metropolitan subway. Among investigated areas, the levels of airborne bacteria and fungi in the workers' bedroom and station precincts were relatively high. No significant difference was found in the concentration of airborne bacteria and fungi between the underground and above ground activity areas of the subway. The genera identified in all subway activity areas with a 5% or greater detection rate were Staphylococcus, Micrococcus, Bacillus and Corynebacterium for airborne bacteria and Penicillium, Cladosporium, Chrysosporium, Aspergillus for airborne fungi. Staphylococcus and Micrococcus comprised over 50% of the total airborne bacteria and Penicillium and Cladosporium comprised over 60% of the total airborne fungi, thus these four genera are the predominant genera in the subway station.

  5. Investigation of the exposure level of electromagnetic fields produced by mobile telephone base stations

    International Nuclear Information System (INIS)

    Abukassem, I.; Kharita, M. H.

    2010-12-01

    The aim of this work is to investigate the real values of microwave level distribution and propagation in the locality around samples of mobile phone base station, and to compare the results with the exposure restriction limits recommenced by the International Commission on Non Ionizing Radiation Protection (ICNIRP). Measurements were performed using special meters for microwaves; the first (Narda SRM-3000) is used for electromagnetic waves frequency spectrum scanning and the second (NARDA) emr 300) determine the level of electric and magnetic fields and the power density of these waves nearby any sort of transmitters. Samples of different kinds of mobile phone base station were chosen to cover important zones of Damascus, and the region around each base station was also scanned in the emission direction and according to accessibility into the studies positions. Results showed that the signal level in all measured points is lower than the ICNIRP restriction level, but for few points the detected microwave level has relatively important values. The signal level inside building situated partially in the emission direction of the base station transmitters decreases stepwise and walls reduce considerably the signal intensity. To realize these kind of field studies in the best way and obtain the maximum profits for all people, the properties and operating system of transmitters used in mobile phone base station must be known, and therefore, it is very important to achieve a transparent collaboration between research laboratory and mobile phone company. (author)

  6. Design and implementation of a wireless sensor network-based remote water-level monitoring system.

    Science.gov (United States)

    Li, Xiuhong; Cheng, Xiao; Gong, Peng; Yan, Ke

    2011-01-01

    The proposed remote water-level monitoring system (RWMS) consists of a field sensor module, a base station module, a data center module and a WEB releasing module. It has advantages in real time and synchronized remote control, expandability, and anti-jamming capabilities. The RWMS can realize real-time remote monitoring, providing early warning of events and protection of the safety of monitoring personnel under certain dangerous circumstances. This system has been successfully applied in Poyanghu Lake. The cost of the whole system is approximately 1,500 yuan (RMB).

  7. Design and Implementation of a Wireless Sensor Network-Based Remote Water-Level Monitoring System

    Science.gov (United States)

    Li, Xiuhong; Cheng, Xiao; Gong, Peng; Yan, Ke

    2011-01-01

    The proposed remote water-level monitoring system (RWMS) consists of a field sensor module, a base station module, adata center module and aWEB releasing module. It has advantages in real time and synchronized remote control, expandability, and anti-jamming capabilities. The RWMS can realize real-time remote monitoring, providing early warning of events and protection of the safety of monitoring personnel under certain dangerous circumstances. This system has been successfully applied in Poyanghu Lake. The cost of the whole system is approximately 1,500 yuan (RMB). PMID:22319377

  8. FY 1994 ambient air monitoring report for McMurdo Station, Antarctica

    International Nuclear Information System (INIS)

    Lugar, R.M.

    1994-12-01

    This report presents the results of ambient air monitoring performed during the 1994 fiscal year (FY 1994) in the vicinity of McMurdo Station, Antarctica. Routine monitoring was performed during the 1993-1994 austral summer at three locations for airborne particulate matter less than 10 micrometers (PM-10) and at two locations for carbon monoxide (CO), sulfur dioxide (SO 2 ), and nitrogen oxides (NO, NO 2 , and NO x ). Selected PM-10 filters were analyzed for arsenic, beryllium, cadmium, chromium, lead, mercury, and nickel. Additional air samples were collected at three McMurdo area locations and at Black Island for determination of the airborne concentration of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs). Sampling site selection, sampling procedures, and quality assurance procedures used were consistent with US Environmental Protection Agency guidance for local ambient air quality networks

  9. The monitoring of the terrestrial environment around Almirante Alvaro Alberto nuclear power station

    Energy Technology Data Exchange (ETDEWEB)

    Tavares, P.G.; Souza, R.F.; Cardoso, S.N.M., E-mail: pgtares@eletronuclear.gov.b, E-mail: rfsouza@eletronuclear.gov.b, E-mail: sergion@eletronuclear.gov.b [ELETROBRAS Eletronuclear S.A., Paraty, RJ (Brazil). Lab. de Monitoracao Ambiental

    2011-07-01

    The goal of this paper is to evaluate the environmental monitoring around Almirante Alvaro Alberto Nuclear Power Station after the beginning the operation of Unit II, in July 2000. The Environmental Monitoring Laboratory (EML) has, for purpose, to monitor the environment around the station to verify if there is a potential impact caused by the operation of the units. The EML collects several environmental samples and analyses radiometrically to determine the presence of artificial radionuclides. The types of the samples are marine samples (sea water, fish, algae, beach sand and sediments), terrestrial (milk, banana, soil, grass, superficial and underground water and river water and sediment) and aerial samples (rain water, airborne for iodine and particulate). This paper only describes the monitoring of terrestrial samples. At the EML, the samples are prepared and analysed following international procedures. The samples of milk, banana, soil, grass, surface and underground water, river water and river sediment are analysed by gamma spectrometry in a multi-channel analyser GENIE-2000 System with High-purity Germanium (HpGe) detectors to determine the activities of the detectable radionuclides. The EML also analyses tritium in surface water by liquid scintillation counting. In addition, analysis of {sup 89}Sr/{sup 90}Sr, by beta counting and {sup 131}I by gamma spectrometry are performed in the processed milk. The results are, then, compared with those obtained in pre-operational time of Angra 1 (1978 - 1982) and those obtained in operational time of the units until 2010. The results show us that, from 1982 until now, there is no impact in terrestrial environment caused by the operation neither of Angra 1 nor both Angra 1 and Angra 2. (author)

  10. The monitoring of the terrestrial environment around Almirante Alvaro Alberto nuclear power station

    International Nuclear Information System (INIS)

    Tavares, P.G.; Souza, R.F.; Cardoso, S.N.M.

    2011-01-01

    The goal of this paper is to evaluate the environmental monitoring around Almirante Alvaro Alberto Nuclear Power Station after the beginning the operation of Unit II, in July 2000. The Environmental Monitoring Laboratory (EML) has, for purpose, to monitor the environment around the station to verify if there is a potential impact caused by the operation of the units. The EML collects several environmental samples and analyses radiometrically to determine the presence of artificial radionuclides. The types of the samples are marine samples (sea water, fish, algae, beach sand and sediments), terrestrial (milk, banana, soil, grass, superficial and underground water and river water and sediment) and aerial samples (rain water, airborne for iodine and particulate). This paper only describes the monitoring of terrestrial samples. At the EML, the samples are prepared and analysed following international procedures. The samples of milk, banana, soil, grass, surface and underground water, river water and river sediment are analysed by gamma spectrometry in a multi-channel analyser GENIE-2000 System with High-purity Germanium (HpGe) detectors to determine the activities of the detectable radionuclides. The EML also analyses tritium in surface water by liquid scintillation counting. In addition, analysis of 89 Sr/ 9 0 Sr, by beta counting and 131 I by gamma spectrometry are performed in the processed milk. The results are, then, compared with those obtained in pre-operational time of Angra 1 (1978 - 1982) and those obtained in operational time of the units until 2010. The results show us that, from 1982 until now, there is no impact in terrestrial environment caused by the operation neither of Angra 1 nor both Angra 1 and Angra 2. (author)

  11. Construction of research wind-solar monitoring station 'North-East Bulgaria'

    International Nuclear Information System (INIS)

    Mateeva, Z.; Filipov, A.; Filipov, V.

    2008-01-01

    The rising energy prices, the lack of conventional energy sources, as well as the growing ecological problems, imposing the development of a new energy strategy of Bulgaria, are the prerequisites for the thorough researches in the field of wind-solar resources and the construction of experimental bases with modern equipment for the detailed investigations on the specificities of these resources with the view of their optimal utilization. The lack of homogenous covering of the territory of the country with meteorological stations, as well as the rather specific microclimatic conditions in the diverse physical-geographic localities in the country make the necessity of building experimental stations for meteo-monitoring under specific local conditions still more indispensable. This work presents the monitoring parameters of wind-solar resources in a real physical-geographic environment, for carrying out scientific-research, applied-practical and educational-training activity. A broad spectrum of scientific methods and approaches - instrumental, topographic, terrain, mathematical-statistical, numerical modeling, cartographic, educational and team-working, are envisaged for attaining the set objective. (author)

  12. Microseismic Monitoring of Strainburst Activities in Deep Tunnels at the Jinping II Hydropower Station, China

    Science.gov (United States)

    Xu, N. W.; Li, T. B.; Dai, F.; Zhang, R.; Tang, C. A.; Tang, L. X.

    2016-03-01

    Rockbursts were frequently encountered during the construction of deep tunnels at the Jinping II hydropower station, Southwest China. Investigations of the possibility of rockbursts during tunnel boring machine (TBM) and drilling and blasting (D&B) advancement are necessary to guide the construction of tunnels and to protect personnel and TBM equipment from strainburst-related accidents. A real-time, movable microseismic monitoring system was installed to forecast strainburst locations ahead of the tunnel faces. The spatiotemporal distribution evolution of microseismic events prior to and during strainbursts was recorded and analysed. The concentration of microseismic events prior to the occurrence of strainbursts was found to be a significant precursor to strainbursts in deep rock tunnelling. During a 2-year microseismic investigation of strainbursts in the deep tunnels at the Jinping II hydropower station, a total of 2240 strainburst location forecasts were issued, with 63 % correctly forecasting the locations of strainbursts. The successful forecasting of strainburst locations proved that microseismic monitoring is essential for the assessment and mitigation of strainburst hazards, and can be used to minimise damage to equipment and personnel. The results of the current study may be valuable for the construction management and safety assessment of similar underground rock structures under high in situ stress.

  13. Metropolitan garbage dumps: possible winter migratory raptor monitoring stations in peninsular India

    Directory of Open Access Journals (Sweden)

    S. Pande

    2010-09-01

    Full Text Available Winter raptor migration and movement is poorly documented for peninsular India, mainly due to the lack of geographical bottlenecks. We describe, for the first time, the use of a garbage dump in a metropolitan city as an alternative visual winter raptor monitoring station. The daily count, adult to juvenile ratios and species composition of three migratory raptor species, Steppe Eagle Aquila nipalensis, Black-eared Kite Milvus migrans lineatus and Tawny Eagle Aquila rapax are presented. Ground temperatures at the garbage dump site and surrounding area, and the wing beat rate of migratory raptors before and after arrival in the early morning were measured. A total of 355 raptors migrating over a period of six observation days with 250 adults and 105 juveniles were recorded. The temperature of the garbage dump was significantly higher than the surrounding area, while the wing flapping rate was significantly lower over the garbage dump area. It is possible that migrating raptors use garbage dump thermals in the early morning to save energy with soaring and gliding flight (versus flapping flight. We propose that such sites may be used as visual winter migration monitoring stations in metropolitan cities in peninsular India.

  14. Project of a Near-Real-Time Sismo-acoustic Submarine Station for offshore monitoring (NRTSSS)

    Science.gov (United States)

    D'Anna, G.; Calore, D.; Mangano, G.; D'Alessandro, A.; Favali, P.

    2011-12-01

    The INGV seismic network ensures reliable and continuous monitoring of the Italian territory. However, the peculiarity of the Italian peninsula, characterised by an intense offshore geodynamic and seismic activity, requires the extension of the seismic monitoring to the sea. The aim of this project is: - to identify bottleneck is related to the construction, installation and use of underwater seismic station; - to define the most appropriate and low-cost architecture to guarantee the minimum functionality required for a seismic station. In order to obtain reliable seafloor seismic signals integrated to land-based network, the requirements to be fulfill are: - an acceptable coupling with the seabed; - the orientation of the components with respect to the magnetic North and to the verticality; - the correct time stamp of the data; - the data transfer to the land for the integration. Currently, the optimal solution for offshore seismic station is a cable connection to power and real-time data transfer, like the case of Western Ionian Sea cabled observatory, one of the operative node of the EMSO research infrastructure (European Multidisciplinary Seafloor and water column Observatory, http://emso-eu.org). But in the Mediterranean many seismic areas are located a few tens-hundreds of miles from the coast and cabled solutions are not feasible essentially for economic reasons. For this kind of installations EMSO research infrastructure foresees no-cabled solution, that requires a surface buoy deployed in the vicinity seafloor modules.This project plans to develop a surface buoy equipped with autonomous power supply system to power also the seafloor platforms and two-way communication system enabling the data transfer through latest generation of broadband radio communication or satellite link (Fig. 1). All the components of the prototype system are described.

  15. China Dimensions Data Collection: Chinese County-Level Data on Hospitals and Epidemiology Stations, 1950-1985

    Data.gov (United States)

    National Aeronautics and Space Administration — Chinese County-Level Data on Hospitals and Epidemiology Stations, 1950-1985 consists of hospital and epidemiological station data for the administrative regions of...

  16. Radiation monitoring using manned helicopter around the nuclear power station in the fiscal year 2015 (Contract research)

    International Nuclear Information System (INIS)

    Sanada, Yukihisa; Munakata, Masahiro; Mori, Airi; Ishizaki, Azusa; Shimada, Kazumasa; Hirouchi, Jun; Urabe, Yoshimi; Nakanishi, Chika; Yamada, Tsutomu; Iwai, Takeyuki; Matsunaga, Yuki; Toyoda, Masayuki; Tobita, Shinichiro; Nishizawa, Yukiyasu; Ishida, Mutsushi; Sato, Yoshiharu; Sasaki, Miyuki; Hirayama, Hirokatsu; Takamura, Yoshihide; Nishihara, Katsuya; Imura, Mitsuo; Miyamoto, Kenji; Kudo, Tamotsu; Nakayama, Shinichi

    2016-10-01

    By the nuclear disaster of Fukushima Daiichi Nuclear Power Station (FDNPS), Tokyo Electric Power Company (TEPCO), caused by the East Japan earthquake and the following tsunami occurred on March 11, 2011, a large amount of radioactive materials was released from the NPS. After the nuclear disaster, airborne radiation monitoring using manned helicopter was conducted around FDNPS. In addition, background dose rate monitoring was conducted around the Sendai Nuclear Power Station. These results of the aerial radiation monitoring using the manned helicopter in the fiscal 2015 were summarized in the report. In addition, we developed the discrimination technique of the Rn-progenies and the evaluation of radiation attenuation by snow. (author)

  17. Monitoring equipment environment during nuclear plant operation at Salem and Hope Creek generating stations

    International Nuclear Information System (INIS)

    Blum, A.; Smith, R.J.

    1991-01-01

    Monitoring of environmental parameters has become a significant issue for operating nuclear power plants. While the long-term benefits of plant life extension programs are being pursued with comprehensive environmental monitoring programs, the potential effect of local hot spots at various plant locations needs to be evaluated for its effect on equipment degradation and shortening of equipment qualified life. A significant benefit can be experienced from temperature monitoring when a margin exists between the design versus actual operating temperature. This margin can be translated into longer equipment qualified life and significant reduction in maintenance activities. At PSE and G, the immediate need for monitoring environmental parameters is being accomplished via the use of a Logic Beach Bitlogger. The Bitlogger is a portable data loggings system consisting of a system base, input modules and a communication software package. Thermocouples are installed on selected electrical equipment and cables are run from the thermocouples to the input module of the Bitlogger. Temperature readings are taken at selected intervals, stored in memory, and downloaded periodically to a PC software program, i.e., Lotus. The data is formatted into tabular or graphical documents. Because of their versatility, Bitloggers are being used differently at the authors Nuclear facility. At the Salem Station (2 Units-4 loop Westinghouse PWR), a battery powered, fully portable, calibrated Bitlogger is located in an accessible area inside Containment where it monitors the temperature of various electrical equipment within the Pressurizer Enclosure. It is planned that close monitoring of the local hot spot temperatures in this area will allow them to adjust and reconcile the environmental qualification of the equipment

  18. Global Monitoring of Mountain Glaciers Using High-Resolution Spotlight Imaging from the International Space Station

    Science.gov (United States)

    Donnellan, A.; Green, J. J.; Bills, B. G.; Goguen, J.; Ansar, A.; Knight, R. L.; Hallet, B.; Scambos, T. A.; Thompson, L. G.; Morin, P. J.

    2013-12-01

    Mountain glaciers around the world are retreating rapidly, contributing about 20% to present-day sea level rise. Numerous studies have shown that mountain glaciers are sensitive to global environmental change. Temperate-latitude glaciers and snowpack provide water for over 1 billion people. Glaciers are a resource for irrigation and hydroelectric power, but also pose flood and avalanche hazards. Accurate mass balance assessments have been made for only 280 glaciers, yet there are over 130,000 in the World Glacier Inventory. The rate of glacier retreat or advance can be highly variable, is poorly sampled, and inadequately understood. Liquid water from ice front lakes, rain, melt, or sea water and debris from rocks, dust, or pollution interact with glacier ice often leading to an amplification of warming and further melting. Many mountain glaciers undergo rapid and episodic events that greatly change their mass balance or extent but are sparsely documented. Events include calving, outburst floods, opening of crevasses, or iceberg motion. Spaceborne high-resolution spotlight optical imaging provides a means of clarifying the relationship between the health of mountain glaciers and global environmental change. Digital elevation models (DEMs) can be constructed from a series of images from a range of perspectives collected by staring at a target during a satellite overpass. It is possible to collect imagery for 1800 targets per month in the ×56° latitude range, construct high-resolution DEMs, and monitor changes in high detail over time with a high-resolution optical telescope mounted on the International Space Station (ISS). Snow and ice type, age, and maturity can be inferred from different color bands as well as distribution of liquid water. Texture, roughness, albedo, and debris distribution can be estimated by measuring bidirectional reflectance distribution functions (BRDF) and reflectance intensity as a function of viewing angle. The non-sun-synchronous orbit

  19. Investigation of the exposure level of electromagnetic fields produced by mobile telephone base stations

    International Nuclear Information System (INIS)

    Abukassem, I.; Kharita, M.H.

    2011-01-01

    The electromagnetic field levels in the surrounding of different samples of mobile phone base station were investigated in order to cover residential zones of Damascus and her environs. Measurements were achieved according to the emission direction and to the studied positions environment. Results showed that the signal level in all measured points is lower than the International Commission on Non Ionizing Radiation Protection (ICNIRP) restriction level, but for few measurement points the detected microwave level has relatively important values. The signal level inside building situated partially in the emission direction of the base station transmitters decreases stepwise and walls reduce considerably the signal intensity. This study showed the importance of achieving a transparent collaboration between research laboratory and mobile phone companies in order to improve the protection level.(author)

  20. Identification of Homogeneous Stations for Quality Monitoring Network of Mashhad Aquifer Based on Nitrate Pollution

    Directory of Open Access Journals (Sweden)

    Moslem Akbarzadeh

    2017-01-01

    Full Text Available Introduction: For water resources monitoring, Evaluation of groundwater quality obtained via detailed analysis of pollution data. The most fundamental analysis is to identify the exact measurement of dangerous zones and homogenous station identification in terms of pollution. In case of quality evaluation, the monitoring improvement could be achieved via identifying homogenous wells in terms of pollution. Presenting a method for clustering is essential in large amounts of quality data for aquifer monitoring and quality evaluation, including identification of homogeneous stations of monitoring network and their clustering based on pollution. In this study, with the purpose of Mashhad aquifer quality evaluation, clustering have been studied based on Euclidean distance and Entropy criteria. Cluster analysis is the task of grouping a set of objects in such a way that objects in the same group (called a cluster are more similar (in some sense or another to each other than to those in other groups (clusters. SNI as a combined entropy measure for clustering calculated from dividing mutual information of two values (pollution index values to the joint entropy. These measures apply as similar distance criteria for monitoring stations clustering. Materials and Methods: First, nitrate data (as pollution index and electrical conductivity (EC (as covariate collected from the related locational situation of 287 wells in statistical period 2002 to 2011. Having identified the outlying data and estimating non-observed points by spatial-temporal Kriging method and then standardizes them, the clustering process was carried out. A similar distance of wells calculated through a clustering process based on Euclidean distance and Entropy (SNI criteria. This difference explained by characteristics such as the location of wells (longitude & latitude and the pollution index (nitrate. Having obtained a similar distance of each well to others, the hierarchical clustering

  1. GULF OF MEXICO SEAFLOOR STABILITY AND GAS HYDRATE MONITORING STATION PROJECT

    Energy Technology Data Exchange (ETDEWEB)

    J. Robert Woolsey; Thomas M. McGee; Robin C. Buchannon

    2004-11-01

    The gas hydrates research Consortium (HRC), established and administered at the University if Mississippi's Center for Marine Research and Environmental Technology (CMRET) has been active on many fronts in FY 03. Extension of the original contract through March 2004, has allowed completion of many projects that were incomplete at the end of the original project period due, primarily, to severe weather and difficulties in rescheduling test cruises. The primary objective of the Consortium, to design and emplace a remote sea floor station for the monitoring of gas hydrates in the Gulf of Mexico by the year 2005 remains intact. However, the possibility of levering HRC research off of the Joint Industries Program (JIP) became a possibility that has demanded reevaluation of some of the fundamental assumptions of the station format. These provisions are discussed in Appendix A. Landmark achievements of FY03 include: (1) Continuation of Consortium development with new researchers and additional areas of research contribution being incorporated into the project. During this period, NOAA's National Undersea Research Program's (NURP) National Institute for Undersea Science and Technology (NIUST) became a Consortium funding partner, joining DOE and Minerals Management Service (MMS); (2) Very successful annual and semiannual meetings in Oxford Mississippi in February and September, 2003; (3) Collection of piston cores from MC798 in support of the effort to evaluate the site for possible monitoring station installation; (4) Completion of the site evaluation effort including reports of all localities in the northern Gulf of Mexico where hydrates have been documented or are strongly suspected to exist on the sea floor or in the shallow subsurface; (5) Collection and preliminary evaluation of vent gases and core samples of hydrate from sites in Green Canyon and Mississippi Canyon, northern Gulf of Mexico; (6) Monitoring of gas activity on the sea floor, acoustically

  2. 42 CFR 403.754 - Monitoring expenditure level.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Monitoring expenditure level. 403.754 Section 403..., Conditions of Participation, and Payment § 403.754 Monitoring expenditure level. (a) Tracking expenditures... between the trigger level and Medicare expenditures for a FFY results in a carry forward that either...

  3. Experience with the TUeV pipe monitoring system at the Grohnde nuclear power station

    International Nuclear Information System (INIS)

    Dittmar, H.; Hofstoetter, P.

    1995-01-01

    A special pipe monitoring system has been developed by TUeV Rheinland during the construction, commissioning and operation of the Grohnde nuclear power station. On the basis of measurements during construction and commissioning a basic monitoring system has been developed, using not only a system of sophisticated sensors that had been permanently installed from the beginning but also a large number of quite simple additional sensors. Measurements were taken before, during and after inspections and led to the discovery of unexpected and high stresses during service as well as to long-term changes over a period of years.Special measurements were taken with high temperature strain gauges and thermocouples to identify problems such as temperature layering. A special on-line measuring device was developed and used for the continuous monitoring of temperatures during operation.All these measurements help to identify out areas with high stresses or service conditions giving rise to high loads, in order on the one hand to prevent damage and on the other hand to prove that the pipes are functioning within their design parameters without problems. ((orig.))

  4. Monitoring the Microgravity Environment Quality On-Board the International Space Station Using Soft Computing Techniques

    Science.gov (United States)

    Jules, Kenol; Lin, Paul P.

    2001-01-01

    This paper presents an artificial intelligence monitoring system developed by the NASA Glenn Principal Investigator Microgravity Services project to help the principal investigator teams identify the primary vibratory disturbance sources that are active, at any moment in time, on-board the International Space Station, which might impact the microgravity environment their experiments are exposed to. From the Principal Investigator Microgravity Services' web site, the principal investigator teams can monitor via a graphical display, in near real time, which event(s) is/are on, such as crew activities, pumps, fans, centrifuges, compressor, crew exercise, platform structural modes, etc., and decide whether or not to run their experiments based on the acceleration environment associated with a specific event. This monitoring system is focused primarily on detecting the vibratory disturbance sources, but could be used as well to detect some of the transient disturbance sources, depending on the events duration. The system has built-in capability to detect both known and unknown vibratory disturbance sources. Several soft computing techniques such as Kohonen's Self-Organizing Feature Map, Learning Vector Quantization, Back-Propagation Neural Networks, and Fuzzy Logic were used to design the system.

  5. The JPL Electronic Nose: Monitoring Air in the US Lab on the International Space Station

    Science.gov (United States)

    Ryan, M. A.; Manatt, K. S.; Gluck, S.; Shevade, A. V.; Kisor, A. K.; Zhou, H.; Lara, L. M.; Homer, M. L.

    2010-01-01

    An electronic nose with a sensor array of 32 conductometric sensors has been developed at the Jet Propulsion Laboratory (JPL) to monitor breathing air in spacecraft habitat. The Third Generation ENose is designed to operate in the environment of the US Lab on the International Space Station (ISS). It detects a selected group of analytes at target concentrations in the ppm regime at an environmental temperature range of 18 - 30 oC, relative humidity from 25 - 75% and pressure from 530 to 760 torr. The monitoring targets are anomalous events such as leaks and spills of solvents, coolants or other fluids. The JPL ENose operated as a technology demonstration for seven months in the U.S. Laboratory Destiny during 2008-2009. Analysis of ENose monitoring data shows that there was regular, periodic rise and fall of humidity and occasional releases of Freon 218 (perfluoropropane), formaldehyde, methanol and ethanol. There were also several events of unknown origin, half of them from the same source. Each event lasted from 20 to 100 minutes, consistent with the air replacement time in the US Lab.

  6. The development of on-line thermal performance monitors in Nuclear Electric Company's stations

    International Nuclear Information System (INIS)

    Conner, A.S.

    1992-01-01

    The paper examines the economic benefits of using on-line monitoring techniques in assisting Station Staff with the task of optimising the efficient use of reactor fuel. The role of thermal performance monitoring for detecting changes in plant condition is also examined and the way in which the data can be used by engineers to assist with the preparation of operating and maintenance programmes. To enable genuine gradual changes in plant performance to be detected when operating against a background of changing plant signal accuracy conditions, plant transducers have to be calibrated on a regular basis. This can be both costly and labour intensive. To reduce this requirement for regular calibrations, an automatic software signal verification program has been developed for use in on-line monitoring schemes. It forms part of the total unit performance calculation package and uses a whole plant model to verify plant signals. All plant signals used to calculate unit heat rate are verified typically every 15 minutes with signals going outside predetermined limits being automatically reported to the user. The program is interactive allowing the user to interrogate the condition of the signal, with respect to both its error magnitude and rate of drift outside signal limits. The program runs in real time mode on a Workstation connected directly to the plant

  7. Efficient species-level monitoring at the landscape scale

    Science.gov (United States)

    Barry R. Noon; Larissa L. Bailey; Thomas D. Sisk; Kevin S. McKelvey

    2012-01-01

    Monitoring the population trends of multiple animal species at a landscape scale is prohibitively expensive. However, advances in survey design, statistical methods, and the ability to estimate species presence on the basis of detection­nondetection data have greatly increased the feasibility of species-level monitoring. For example, recent advances in monitoring make...

  8. Dynamic characteristics of background seismic noise according to records of nuclear monitoring seismic stations in Kazakstan

    International Nuclear Information System (INIS)

    Belyashova, N.N.; Sinyova, Z.I.; Komarov, I.I.; Mikhailova, N.N.

    1998-01-01

    The seismic stations of Kazakstan, included into nuclear monitoring network (see fig.1) are equipped with broad hand seismometers; seismic data are recorded in digital format. All this allows to investigate spectral and time characteristics of seismic background noise in very large frequency diapason (more than 3-5 orders), for all three components of oscillation vector. The spectral density of background seismic noise for vertical and both horizontal components (fig.2) was calculated for all of the observation points. The regular features of structure of noise spectra, inherent for all of the studied observation points, as well as some features, specific for studied places were found. The curves of spectral noise density were compared with global noise model, determined by the data of Global Seismological Network (GSN)

  9. Summarization of radioactive effluent monitoring in Daya Bay Nuclear Power Station 1994-2002

    International Nuclear Information System (INIS)

    Ouyang Junjie; Chen Yue

    2004-01-01

    This paper introduces the radioactive effluent monitoring systems, measurement and quality control methods used in Daya Bay Nuclear Power Station from its commercial operation in 1994. The main work and experiences for the management of effluent release are discussed and analyzed. The radwaste data appear declining trend and are far blow the annual limit approved by the national Environmental Protection Bureau since 1995. The normalized release (unit GBq/GWa) of 9 years is as follows: liquid nuclides (except tritium) 11.1, liquid tritium 1.91 x 10 4 , noble gas 2.03 x 10 4 , halogen 0.13, aerosol 7.57 x 10 -3 . For 110m Ag, the average release from 1998 to 2002 has been reduced to 1/7 of the quantity in 1997

  10. Development and Characterization of Tissue Equivalent Proportional Counter for Radiation Monitoring in International Space Station

    Directory of Open Access Journals (Sweden)

    Uk-Won Nam

    2013-06-01

    Full Text Available Tissue equivalent proportional counter (TEPC can measure the Linear Energy Transfer (LET spectrum and calculate the equivalent dose for the complicated radiation field in space. In this paper, we developed and characterized a TEPC for radiation monitoring in International Space Station (ISS. The prototype TEPC which can simulate a 2 μm of the site diameter for micro-dosimetry has been tested with a standard alpha source (241Am, 5.5 MeV. Also, the calibration of the TEPC was performed by the 252Cf neutron standard source in Korea Research Institute of Standards and Science (KRISS. The determined calibration factor was kf = 3.59×10-7 mSv/R.

  11. Association between air pollution and hospital admission: Case study at three monitoring stations in Malaysia

    Science.gov (United States)

    Zahari, Marina; Zin@Ibrahim, Wan Zawiah Wan; Ismail, Noriszura; Ni, Tan Hui

    2014-06-01

    The relationships between the exposure of pollutants towards hospitalized admission and mortality have been identified in several studies on Asian cities such as Taipei, Bangkok and Tokyo. In Malaysia, evidence on the health risks associated with exposure to pollutants is limited. In this study, daily time-series data were analysed to estimate risks of cardiovascular and respiratory hospitalized admissions associated with particulate matter ≤ 10 μm (PM10), carbon monoxide (CO), nitrogen dioxide, sulphur dioxide, and ozone concentrations in Klang Valley during 2004-2009. Daily counts of hospital admissions for cardiovascular and respiratory outcomes were obtained from eleven hospitals while pollutants data were taken from several air quality monitoring stations located nearest to the hospitals. These data were fitted with Generalised Additive Poisson regression models. Additionally, temperature, humidity, and time data were also included to allow for potential effect of weather and time-varying influences on hospital admissions. CO showed the most significant (P Malaysia.

  12. The Rover Environmental Monitoring Station Ground Temperature Sensor: A Pyrometer for Measuring Ground Temperature on Mars

    Directory of Open Access Journals (Sweden)

    Miguel Ramos

    2010-10-01

    Full Text Available We describe the parameters that drive the design and modeling of the Rover Environmental Monitoring Station (REMS Ground Temperature Sensor (GTS, an instrument aboard NASA’s Mars Science Laboratory, and report preliminary test results. REMS GTS is a lightweight, low-power, and low cost pyrometer for measuring the Martian surface kinematic temperature. The sensor’s main feature is its innovative design, based on a simple mechanical structure with no moving parts. It includes an in-flight calibration system that permits sensor recalibration when sensor sensitivity has been degraded by deposition of dust over the optics. This paper provides the first results of a GTS engineering model working in a Martian-like, extreme environment.

  13. Simplified conversions between specific conductance and salinity units for use with data from monitoring stations

    Science.gov (United States)

    Schemel, Laurence E.

    2001-01-01

    The U.S. Geological Survey, Bureau of Reclamation, and the California Department of Water Resources maintain a large number of monitoring stations that record specific conductance, often referred to as “electrical conductivity,” in San Francisco Bay Estuary and the Sacramento-San Joaquin Delta. Specific conductance units that have been normalized to a standard temperature are useful in fresh waters, but conversion to salinity units has some considerable advantages in brackish waters of the estuary and Delta. For example, salinity is linearly related to the mixing ratio of freshwater and seawater, which is not the case for specific conductance, even when values are normalized to a standard temperature. The Practical Salinity Scale 1978 is based on specific conductance, temperature, and pressure measurements of seawater and freshwater mixtures (Lewis 1980 and references therein). Equations and data that define the scale make possible conversions between specific conductance and salinity values.

  14. Nonstandard usage of ASS-500 station filters for determination of ground-level air contamination

    International Nuclear Information System (INIS)

    Kozak, K.; Jasinska, M.; Kwiatek, W.; Mietelski, J.W.; Dutkiewicz, E.

    1998-01-01

    The work describes nonstandard application of filters from ASS-500 station for the determination of the element content in the samples collected by PIXE method. Determination of gamma radioactive isotopes and alpha radioactive plutonium is also reviewed. Authors conclude that ASS-500 workstation allows collection of representative samples from the ground level air. These samples are suitable for the complex analysis of industrial pollution

  15. Development of ICT for Leaching Monitoring in Taiwan Agricultural LTER Stations

    Directory of Open Access Journals (Sweden)

    Yankuang Chan

    2017-06-01

    Full Text Available In order to study the groundwater subsidy from different cropping systems, leaching monitoring in Taiwan started in 2008 and implemented agricultural long-term ecological research (LTER stations. Initially, leaching data was received by lysimeters, and then collected manually by laborers in the field twice per month. The cost of data collection and transmission is high, real-time monitoring is not possible, and maintenance of instruments is inefficient. In this study, the goal is to develop a data transmission path. ICT (Information and Communication Technology with different data transmission schemes was applied to improve the efficiency and immediacy of data transfer from the field to the databases in labs. Between 2010 and 2017, four versions of ICT have been developed and applied in LTER stations. WiFi, 2.5G (General Packet Radio Service, GPRS, 3G/4G network transmission, and Arduino cores are applied in different ICT versions. The first version of data transmission used data loggers, developed by the original factory, with a lower cost of renovation of instruments. However, complicated transmission paths, diverse instruments, poor weather resistance, and lack of wireless functionality are the limitations of the first version. Those limitations had been overcome by the second and third versions by using 2.5G (GPRS and 3G/4G network transmission, respectively. Nevertheless, these versions are limited to the processes of data compression and encryption transmission which were developed by the system vendors. In addition, data can only be collected through the webpage provided by the vendors, instead of being received directly from the database using SQL (Structured Query Language. This is inappropriate for advanced data treatment, organization, and analysis. Finally, the fourth version of data transmission has been developed using Arduino. This system allows redesigning of the data loggers and transmission instrument with more feasibility and

  16. Monitoring of the operation of a nuclear power station with design problems in an importing country: The Almaraz power station

    International Nuclear Information System (INIS)

    Reig, J.

    1984-01-01

    The purpose of this paper is to describe the regulatory activities carried out in Spain as a result of the design problem occurring in the steam generators during operation of Unit I of the Almaraz nuclear power station. First, a brief introduction is given to the operating history and characteristics of Unit I of Almaraz. Particular attention is paid to the specific licences issued subsequent to commercial operation which place limitations on the operation of the station and to the operational incidents of which the Nuclear Safety Council (CSN) has been notified. Next, a description is provided of the safety evaluation carried out by the CSN. Three aspects merit particular attention: methodology, evaluation and conclusions. The methodology applied by an importing country is normally based on that of the country of origin of the design, so that the overall evaluation by the NRC has been considered sufficiently representative of aspects specific to the Almaraz power station. In this regard the importance of international collaboration is clearly seen as a principal instrument for performing the evaluation. In the evaluation a distinction is made between general and specific aspects and between inspection programmes and quality assurance requirements. In addition, the conclusions leading to the requirement of the imposition of additional limitations on the operating licence are stated. Apart from the safety evaluation carried out by the CSN, other regulatory activities have been performed over this two-year period. These activities, which include site inspections, audits of the principal supplier company, other independent calculations and so on, are described. Lastly, the paper refers to the lessons learned from the operation of the above-mentioned unit, which are immediately applicable to other Spanish nuclear power stations. (author)

  17. Comparative study of the base activity levels of the Spanish continental nuclear power stations

    International Nuclear Information System (INIS)

    Gregorides de los Santos y Perez-Minguez, A.M.

    1980-01-01

    In this work the pre-operational activity levels of the sites of some Spanish nuclear power stations are discussed. These power stations are located near the Tagus and Ebro river basins. A report of the communities investigated is made. The total alpha and beta activity as well as the long half life activity has been researched there. The importance of this question is obvious for it gives a regional average of the base activity in the basins of these two big Spanish rivers [fr

  18. Beaver Valley Power Station and Shippingport Atomic Power Station. 1977 annual environmental report: radiological. Volume 2

    International Nuclear Information System (INIS)

    1978-01-01

    The environmental monitoring conducted during 1977 in the vicinity of the Beaver Valley Power Station and the Shippingport Atomic Power Station is described. The environmental monitoring program consists of onsite sampling of water, gaseous, and air effluents, as well as offsite monitoring of water, air, river sediments, and radiation levels in the vicinity of the site. The report discusses releases of small quantities of radioactivity to the Ohio River from the Beaver Valley Power Station and Shippingport Atomic Power Station during 1977

  19. The application of a Grey Markov Model to forecasting annual maximum water levels at hydrological stations

    Science.gov (United States)

    Dong, Sheng; Chi, Kun; Zhang, Qiyi; Zhang, Xiangdong

    2012-03-01

    Compared with traditional real-time forecasting, this paper proposes a Grey Markov Model (GMM) to forecast the maximum water levels at hydrological stations in the estuary area. The GMM combines the Grey System and Markov theory into a higher precision model. The GMM takes advantage of the Grey System to predict the trend values and uses the Markov theory to forecast fluctuation values, and thus gives forecast results involving two aspects of information. The procedure for forecasting annul maximum water levels with the GMM contains five main steps: 1) establish the GM (1, 1) model based on the data series; 2) estimate the trend values; 3) establish a Markov Model based on relative error series; 4) modify the relative errors caused in step 2, and then obtain the relative errors of the second order estimation; 5) compare the results with measured data and estimate the accuracy. The historical water level records (from 1960 to 1992) at Yuqiao Hydrological Station in the estuary area of the Haihe River near Tianjin, China are utilized to calibrate and verify the proposed model according to the above steps. Every 25 years' data are regarded as a hydro-sequence. Eight groups of simulated results show reasonable agreement between the predicted values and the measured data. The GMM is also applied to the 10 other hydrological stations in the same estuary. The forecast results for all of the hydrological stations are good or acceptable. The feasibility and effectiveness of this new forecasting model have been proved in this paper.

  20. Radiation exposure and radon levels in some stations of the Syrian gas company

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Shwekani, R.; Jerbi, B.; Awad, I.

    2006-06-01

    In the present study, exposure levels and radon concentrations have been measured in natural gas production lines at the Syrian gas company. The study area includes gas stations for directories of Der Ezzor, Al-Jbessa, Al-Hassaka, and the middle region. The results showed that radiation exposure rates in remote stations and internal stations were within the natural levels except for two main locations, viz reflex pumps and propane production unites; 3 μSvhr -1 was reported. Radon concentration in Syrian natural gas varied between 15.4 Bqm - 3 and 1141 Bqm - 3; coproduced natural gas was found to contain higher concentration that the free natural gas. In addition, radon concentrations were higher in the central processing facilities that the well heads; these high levels are due to pressurizing and concentrating processes that enhance radon gas and its daughters concentrations in these stations. Moreover, a value of 659 Bqm - 3 in Al-Jbessa directorate gas and 225 Bqm - 3 in Al-Hassaka directorate gas were reported. While the concentration was lower in gas producing safur; a value of 80 Bqm - 3 was observed. On the other hand, maximum radon gas concentrations and its daughters in workplace air environment was found to be relatively high in the gas analysis laboratory and they are due to gas release inside the lab during analysis in addition to good separation of these laboratories from the surrounding environment. (author)

  1. Optical Multi-Gas Monitor Technology Demonstration on the International Space Station

    Science.gov (United States)

    Pilgrim, Jeffrey S.; Wood, William R.; Casias, Miguel E.; Vakhtin, Andrei B,; Johnson, Michael D.; Mudgett, Paul D.

    2014-01-01

    There are a variety of both portable and fixed gas monitors onboard the International Space Station (ISS). Devices range from rack-mounted mass spectrometers to hand-held electrochemical sensors. An optical Multi-Gas Monitor has been developed as an ISS Technology Demonstration to evaluate long-term continuous measurement of 4 gases. Based on tunable diode laser spectroscopy, this technology offers unprecedented selectivity, concentration range, precision, and calibration stability. The monitor utilizes the combination of high performance laser absorption spectroscopy with a rugged optical path length enhancement cell that is nearly impossible to misalign. The enhancement cell serves simultaneously as the measurement sampling cell for multiple laser channels operating within a common measurement volume. Four laser diode based detection channels allow quantitative determination of ISS cabin concentrations of water vapor (humidity), carbon dioxide, ammonia and oxygen. Each channel utilizes a separate vertical cavity surface emitting laser (VCSEL) at a different wavelength. In addition to measuring major air constituents in their relevant ranges, the multiple gas monitor provides real time quantitative gaseous ammonia measurements between 5 and 20,000 parts-per-million (ppm). A small ventilation fan draws air with no pumps or valves into the enclosure in which analysis occurs. Power draw is only about 3 W from USB sources when installed in Nanoracks or when connected to 28V source from any EXPRESS rack interface. Internal battery power can run the sensor for over 20 hours during portable operation. The sensor is controlled digitally with an FPGA/microcontroller architecture that stores data internally while displaying running average measurements on an LCD screen and interfacing with the rack or laptop via USB. Design, construction and certification of the Multi-Gas Monitor were a joint effort between Vista Photonics, Nanoracks and NASA-Johnson Space Center (JSC

  2. Marine Corps Contract Supply Model for High Quality Male Enlistment Contracts at the Recruiting Sub Station Level

    National Research Council Canada - National Science Library

    Welsh, Brian K

    2008-01-01

    .... This research develops contract production models at the Recruiting Sub Station level to estimate the effects of local economic conditions, demographics, and recruiting resources on new high quality...

  3. Monitoring for vertical creep in concrete in two silos at Wivenhoe pumped storage hydro power station

    Energy Technology Data Exchange (ETDEWEB)

    Harris, M W [Queensland Univ. of Technology, Brisbane (Australia). School of Surveying

    1997-12-31

    The need for structural monitoring is generated by expected or unexpected (newly discovered in the life of the structure) behaviour. Due to the long vertical driveshafts involved at Wivenhoe the phenomenon of `concrete creep` which, if it is occurring, could contribute to shaft misalignment and unscheduled bearing wear or failure, was used as a motivation to establish a vertical monitoring system. The particular system developed for this site is traceable, replaceable, expandable and inexpensive. Measurements are obtained by precise levelling and the use of specially calibrated vertically suspended tapes. The analysis of the vertical loops is performed using constrained variance estimation and `robust` inter-epoch comparison. (orig.)

  4. Monitoring for vertical creep in concrete in two silos at Wivenhoe pumped storage hydro power station

    Energy Technology Data Exchange (ETDEWEB)

    Harris, M.W. [Queensland Univ. of Technology, Brisbane (Australia). School of Surveying

    1996-12-31

    The need for structural monitoring is generated by expected or unexpected (newly discovered in the life of the structure) behaviour. Due to the long vertical driveshafts involved at Wivenhoe the phenomenon of `concrete creep` which, if it is occurring, could contribute to shaft misalignment and unscheduled bearing wear or failure, was used as a motivation to establish a vertical monitoring system. The particular system developed for this site is traceable, replaceable, expandable and inexpensive. Measurements are obtained by precise levelling and the use of specially calibrated vertically suspended tapes. The analysis of the vertical loops is performed using constrained variance estimation and `robust` inter-epoch comparison. (orig.)

  5. Monitoring Vertical Crustal Deformation and Gravity Variations during Water Level Changes at the Three Gorges Reservoir

    Directory of Open Access Journals (Sweden)

    WANG Wei

    2017-06-01

    Full Text Available Monitoring vertical crustal deformation and gravity changes during water level changes at the Three Gorges reservoir is important for the safe operation of the Three Gorges Dam and for the monitoring and prevention of a regional geological disaster. In this study, we determined vertical crustal deformation and gravity changes during water level variations of the Three Gorges reservoir from direct calculations and actual measurements and a comprehensive solution. We used water areas extracted image data from the ZY-3 satellite and water level data to calculate gravity changes and vertical crustal deformation caused by every 5 m change in the water level due to storage and drainage of the Three Gorges reservoir from 145 m to 175 m. The vertical crustal deformation was up to 30 mm. The location of gravity change above 20 μ Gal(1 Gal=10-2 m/s2 was less than 2 km from the centerline of the Yangtze River. The CORS ES13 in Badong, near the reservoir, measured the vertical crustal deformation during water level changes. Because of the small number of CORS and gravity stations in the Three Gorges reservoir area, monitoring deformation and gravity related to changes in the Three Gorges reservoir water level cannot be closely followed. Using 26 CORS and some of the gravity stations in the Three Gorges area and based on loading deformation and the spherical harmonic analysis method, an integrated solution of vertical deformation and gravity variations during water level changes of the reservoir was determined, which is consistent with the actual CORS monitoring results. By comparison, we found that an integrated solution based on a CORS network can effectively enhance the capability of monitoring vertical crustal deformation and gravity changes during water level variations of the reservoir.

  6. Microcontroller based multi-channel ultrasonic level monitoring system

    International Nuclear Information System (INIS)

    Ambastha, K.P.; Chaudhari, Y.V.; Singh, Inder Jeet; Chadda, V.K.

    2004-01-01

    Microcontroller based Multi-channel Ultrasonic Level Monitoring System developed by Computer Division is based on echo ranging techniques to monitor level. The transmitter directs an ultrasonic burst towards the liquid, which gets reflected from the top of the liquid surface. The time taken for ultrasound to travel from the transmitter to the top of liquid surface is measured and used to calculate the liquid level. The system provides for temperature compensation for accurate measurement as the ultrasound velocity depends on the ambient temperature. It can measure liquid level up to 5 meters. A single monitor can be used to measure level in 6 tanks. PC connectivity has been provided via RS 232 and RS 485 for remote operation and data logging of level. A GUI program developed using LABVIEW package displays level on PC monitor. The program provides for pictorial as well as numerical display for level and temperature in the front panel on the PC monitor. A user can monitor level for any or all tanks from the PC. One unit is installed at CIRUS for measuring level in Acid/ Alkali tanks and one is installed at APSARA for measuring water level in the reactor pool. (author)

  7. Monitoring levels of preservative sensitivity in Europe

    DEFF Research Database (Denmark)

    Wilkinson, J D; Shaw, S; Andersen, Klaus Ejner

    2002-01-01

    A 10-year multicentre analysis of the frequency of sensitivity to common preservatives collected in 16 centres in 11 countries has shown stable but persisting high levels of sensitivity to formaldehyde and 5-chloro-2-methyl-4-isothiazolin-3-one + 2-methyl-4-isothiazolin-3-one (MCI/MI). It has also...

  8. Development and radiation evaluation of mobile station for personnel monitoring system based on indigenous plastic scintillator sensor rods

    International Nuclear Information System (INIS)

    Chaudhary, H.S.; Parihar, A.; Senwar, K.R.; Prakash, V.; Rathore, A.S.

    2018-01-01

    The Mobile Station for Personnel Monitoring (MSPM) system has been designed and developed for rapid screening of personnel with respect to radiation contamination during nuclear or radiological emergency; it can also be used for prevention of illicit movement of radioactive sources. The objective was to develop a modular, transportable and easily deployable gamma portal monitoring system based on indigenous DLJ developed plastic scintillator sensors. The Gamma radiation response of the system is presented here

  9. Continuous atmospheric monitoring of the injected CO2 behavior over geological storage sites using flux stations: latest technologies and resources

    Science.gov (United States)

    Burba, George; Madsen, Rodney; Feese, Kristin

    2014-05-01

    Flux stations have been widely used to monitor emission rates of CO2 from various ecosystems for climate research for over 30 years [1]. The stations provide accurate and continuous measurements of CO2 emissions with high temporal resolution. Time scales range from 20 times per second for gas concentrations, to 15-minute, hourly, daily, and multi-year periods. The emissions are measured from the upwind area ranging from thousands of square meters to multiple square kilometers, depending on the measurement height. The stations can nearly instantaneously detect rapid changes in emissions due to weather events, as well as changes caused by variations in human-triggered events (pressure leaks, control releases, etc.). Stations can also detect any slow changes related to seasonal dynamics and human-triggered low-frequency processes (leakage diffusion, etc.). In the past, station configuration, data collection and processing were highly-customized, site-specific and greatly dependent on "school-of-thought" practiced by a particular research group. In the last 3-5 years, due to significant efforts of global and regional CO2 monitoring networks (e.g., FluxNet, Ameriflux, Carbo-Europe, ICOS, etc.) and technological developments, the flux station methodology became fairly standardized and processing protocols became quite uniform [1]. A majority of current stations compute CO2 emission rates using the eddy covariance method, one of the most direct and defensible micrometeorological techniques [1]. Presently, over 600 such flux stations are in operation in over 120 countries, using permanent and mobile towers or moving platforms (e.g., automobiles, helicopters, and airplanes). Atmospheric monitoring of emission rates using such stations is now recognized as an effective method in regulatory and industrial applications, including carbon storage [2-8]. Emerging projects utilize flux stations to continuously monitor large areas before and after the injections, to locate and

  10. Research on the optimization of air quality monitoring station layout based on spatial grid statistical analysis method.

    Science.gov (United States)

    Li, Tianxin; Zhou, Xing Chen; Ikhumhen, Harrison Odion; Difei, An

    2018-05-01

    In recent years, with the significant increase in urban development, it has become necessary to optimize the current air monitoring stations to reflect the quality of air in the environment. Highlighting the spatial representation of some air monitoring stations using Beijing's regional air monitoring station data from 2012 to 2014, the monthly mean particulate matter concentration (PM10) in the region was calculated and through the IDW interpolation method and spatial grid statistical method using GIS, the spatial distribution of PM10 concentration in the whole region was deduced. The spatial distribution variation of districts in Beijing using the gridding model was performed, and through the 3-year spatial analysis, PM10 concentration data including the variation and spatial overlay (1.5 km × 1.5 km cell resolution grid), the spatial distribution result obtained showed that the total PM10 concentration frequency variation exceeded the standard. It is very important to optimize the layout of the existing air monitoring stations by combining the concentration distribution of air pollutants with the spatial region using GIS.

  11. Performance Evaluation of wastewater treatment plant of Noosh Azar company by online monitoring station

    Directory of Open Access Journals (Sweden)

    leila haddadi

    2018-02-01

    Full Text Available Background& Objective: One of the reuses of wastewater in industries is irrigation of green space. Therefore, with proper treatment and reduction of environmental pollution of wastewater and in compliance with environmental standards, it can be used for irrigation purposes. The present study was aimed to evaluate the performance of Noosh Azar Wastewater Treatment Plant by the online monitoring station in 2016.   Materials and Methods: This descriptive cross-sectional study was performed at Noosh Azar Waste Water Treatment Plant (WWTP in Tehran. The effluent outlet parameters include COD, BOD, TSS, TOC, Turbidity, pH and temperature which were measured 12 times/day by the online monitoring station of the refinery according to the standard methods (the Examinations of Water and Wastewater, and reported at the end of each month. Data were entered into SPSS software and analyzed using statistical indices including mean and standard deviation. Results: The average total of BOD/COD ratio in the wastewater was 0.8. The results of the study showed that the average concentration of COD, BOD and TSS of the wastewater was 1624.91 ±134.85, 1310±75.38 and 283.58± 39.76 mg/L, respectively. The average of total outlet parameters of turbidity, COD, BOD, TSS and TOC were 12.78±2.21, 83.73±12.90, 41.26±6.65, 6.70±2.14, 46.03±7.08 mg/L, and pH=7.80±0.35. The total average of removal efficiencies of COD, BOD and TSS were 93.92±3.62, 96.57±1.002 and 97.57±0.936, respectively. Conclusion: Regarding the proper performance of the activated sludge system of Noosh Azar Company, the effluent  parameters such as COD, BOD, TSS, TOC, turbidity and pH, were in accordance with the standard of the Iranian Environmental Protection Agency for irrigation use. However in order to ensure the quality of the wastewater for reuse, the microbial parameters should also be considered.

  12. Trends in Surface-Water Quality at Selected Ambient-Monitoring Network Stations in Kentucky, 1979-2004

    Science.gov (United States)

    Crain, Angela S.; Martin, Gary R.

    2009-01-01

    Increasingly complex water-management decisions require water-quality monitoring programs that provide data for multiple purposes, including trend analyses, to detect improvement or deterioration in water quality with time. Understanding surface-water-quality trends assists resource managers in identifying emerging water-quality concerns, planning remediation efforts, and evaluating the effectiveness of the remediation. This report presents the results of a study conducted by the U.S. Geological Survey, in cooperation with the Kentucky Energy and Environment Cabinet-Kentucky Division of Water, to analyze and summarize long-term water-quality trends of selected properties and water-quality constituents in selected streams in Kentucky's ambient stream water-quality monitoring network. Trends in surface-water quality for 15 properties and water-quality constituents were analyzed at 37 stations with drainage basins ranging in size from 62 to 6,431 square miles. Analyses of selected physical properties (temperature, specific conductance, pH, dissolved oxygen, hardness, and suspended solids), for major ions (chloride and sulfate), for selected metals (iron and manganese), for nutrients (total phosphorus, total nitrogen, total Kjeldahl nitrogen, nitrite plus nitrate), and for fecal coliform were compiled from the Commonwealth's ambient water-quality monitoring network. Trend analyses were completed using the S-Plus statistical software program S-Estimate Trend (S-ESTREND), which detects trends in water-quality data. The trend-detection techniques supplied by this software include the Seasonal Kendall nonparametric methods for use with uncensored data or data censored with only one reporting limit and the Tobit-regression parametric method for use with data censored with multiple reporting limits. One of these tests was selected for each property and water-quality constituent and applied to all station records so that results of the trend procedure could be compared among

  13. Negotiation and Monitoring of Service Level Agreements

    Science.gov (United States)

    Quillinan, Thomas B.; Clark, Kassidy P.; Warnier, Martijn; Brazier, Frances M. T.; Rana, Omer

    Service level agreements (SLAs) provide a means to define specific Quality of Service (QoS) guarantees between providers and consumers of services. Negotiation and definition of these QoS characteristics is an area of significant research. However, defining the actions that take place when an agreement is violated is a topic of more recent focus. This paper discusses recent advances in this field and propose some additional features that can help both consumers and producers during the enactment of services. These features include the ability to (re)negotiate penalties in an agreement, and specifically focuses on the renegotiation of penalties during enactment to reflect ongoing violations.

  14. Allowable Residual Contamination Levels in soil for decommissioning the Shippingport Atomic Power Station site

    International Nuclear Information System (INIS)

    Kennedy, W.E. Jr.; Napier, B.A.; Soldat, J.K.

    1983-09-01

    As part of decommissioning the Shippingport Atomic Power Station, a fundamental concern is the determination of Allowable Residual Contamination Levels (ARCL) for radionuclides in the soil at the site. The ARCL method described in this report is based on a scenario/exposure-pathway analysis and compliance with an annual dose limit for unrestricted use of the land after decommissioning. In addition to naturally occurring radionuclides and fallout from weapons testing, soil contamination could potentially come from five other sources. These include operation of the Shippingport Station as a pressurized water reactor, operations of the Shippingport Station as a light-water breeder, operation of the nearby Beaver Valley reactors, releases during decommissioning, and operation of other nearby industries, including the Bruce-Mansfield coal-fired power plants. ARCL values are presented for 29 individual radionculides and a worksheet is provided so that ARCL values can be determined for any mixture of the individual radionuclides for any annual dose limit selected. In addition, a worksheet is provided for calculating present time soil concentration value that will decay to the ARCL values after any selected period of time, such as would occur during a period of restricted access. The ARCL results are presented for both unconfined (surface) and confined (subsurface) soil contamination. The ARCL method and results described in this report provide a flexible means of determining unrestricted-use site release conditions after decommissioning the Shippingport Atomic Power Station

  15. Levels of electric field strength within the immediate vicinity of FM radio stations in Accra, Ghana.

    Science.gov (United States)

    Azah, C K; Amoako, J K; Fletcher, J J

    2013-10-01

    Heightened awareness of the ever-expanding use of radiofrequency (RF) techniques and technology has led to mounting concerns from the general public and the scientific community regarding the possible health effects that may arise as a consequence of exposure to RF radiations and has drawn the attention of many researchers the world over. A survey of the RF electromagnetic radiation at public access points in the vicinity of 20 frequency-modulated (FM) radio stations has been made in Accra, Ghana. The fundamental object was to determine the levels of RF fields from FM broadcast antennae within 10-200 m radius about the foot of the FM base station and at a height of 1.5 m above the ground at selected locations. A spectrum analyser and a bi-conical antenna element sensitive and effective within the frequency band of 30-300 MHz were used. Results obtained indicated that the levels of electric field strength ranged from 5.4E-04 V m(-1) at FM station 'O' to 7.4E-08 V m(-1) at FM station 'D'. At a transmission frequency range of 88-108 MHz, the variation of power densities is from 2.5E-10 to 1.5E-17 Wm(-2). These values are very low and are far below the reference level set by the International Commission on Non-Ionizing Radiation Protection and therefore do not pose any known hazard to the inhabitants of Accra, Ghana. The electric field levels presented in this work are comparable with those reported from epidemiological studies conducted elsewhere.

  16. Survey of radiofrequency radiation levels around GSM base stations and evaluation of measurement uncertainty

    Directory of Open Access Journals (Sweden)

    Vulević Branislav D.

    2011-01-01

    Full Text Available This paper is a summary of broadband measurement values of radiofrequency radiation around GSM base stations in the vicinity of residential areas in Belgrade and 12 other cities in Serbia. It will be useful for determining non-ionizing radiation exposure levels of the general public in the future. The purpose of this paper is also an appropriate representation of basic information on the evaluation of measurement uncertainty.

  17. Design/installation and structural integrity assessment under the Federal Facility Agreement for Bethel Valley low-level waste collection and transfer system upgrade for Building 2026 (High Radiation Level Analytical Laboratory) and Building 2099 (Monitoring and Control Station) at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    1994-11-01

    This document presents a Design/Installation and Structural Integrity Assessment for a replacement tank system for portions of the Bethel Valley Low-Level Waste (LLW) System, located at the Oak Ridge Reservation, Oak Ridge, Tennessee. This issue of the assessment covers the design aspects of the replacement tank system, and certifies that the design has sufficient structural integrity and is acceptable for the storing or treating of hazardous and/or radioactive substances. This document will be reissued at a future date and will then include the assessment of the installation of the replacement tank system. The present issue identifies specific activities that must be completed during the fabrication, installation, and testing of the replacement tank system in order to provide assurance that the final installation complies with governing requirements

  18. Rapid Monitoring of Bacteria and Fungi aboard the International Space Station (ISS)

    Science.gov (United States)

    Gunter, D.; Flores, G.; Effinger, M.; Maule, J.; Wainwright, N.; Steele, A.; Damon, M.; Wells, M.; Williams, S.; Morris, H.; hide

    2009-01-01

    Microorganisms within spacecraft have traditionally been monitored with culture-based techniques. These techniques involve growth of environmental samples (cabin water, air or surfaces) on agar-type media for several days, followed by visualization of resulting colonies or return of samples to Earth for ground-based analysis. Data obtained over the past 4 decades have enhanced our understanding of the microbial ecology within space stations. However, the approach has been limited by the following factors: i) Many microorganisms (estimated > 95%) in the environment cannot grow on conventional growth media; ii) Significant time lags (3-5 days for incubation and up to several months to return samples to ground); iii) Condensation in contact slides hinders colony counting by crew; and iv) Growth of potentially harmful microorganisms, which must then be disposed of safely. This report describes the operation of a new culture-independent technique onboard the ISS for rapid analysis (within minutes) of endotoxin and beta-1, 3-glucan, found in the cell walls of gramnegative bacteria and fungi, respectively. The technique involves analysis of environmental samples with the Limulus Amebocyte Lysate (LAL) assay in a handheld device, known as the Lab-On-a-Chip Application Development Portable Test System (LOCAD-PTS). LOCADPTS was launched to the ISS in December 2006, and here we present data obtained from Mach 2007 until the present day. These data include a comparative study between LOCADPTS analysis and existing culture-based methods; and an exploratory survey of surface endotoxin and beta-1, 3-glucan throughout the ISS. While a general correlation between LOCAD-PTS and traditional culture-based methods should not be expected, we will suggest new requirements for microbial monitoring based upon culture-independent parameters measured by LOCAD-PTS.

  19. Monitoring the Microgravity Environment Quality On-board the International Space Station Using Soft Computing Techniques. Part 2; Preliminary System Performance Results

    Science.gov (United States)

    Jules, Kenol; Lin, Paul P.; Weiss, Daniel S.

    2002-01-01

    This paper presents the preliminary performance results of the artificial intelligence monitoring system in full operational mode using near real time acceleration data downlinked from the International Space Station. Preliminary microgravity environment characterization analysis result for the International Space Station (Increment-2), using the monitoring system is presented. Also, comparison between the system predicted performance based on ground test data for the US laboratory "Destiny" module and actual on-orbit performance, using measured acceleration data from the U.S. laboratory module of the International Space Station is presented. Finally, preliminary on-orbit disturbance magnitude levels are presented for the Experiment of Physics of Colloids in Space, which are compared with on ground test data. The ground test data for the Experiment of Physics of Colloids in Space were acquired from the Microgravity Emission Laboratory, located at the NASA Glenn Research Center, Cleveland, Ohio. The artificial intelligence was developed by the NASA Glenn Principal Investigator Microgravity Services Project to help the principal investigator teams identify the primary vibratory disturbance sources that are active, at any moment of time, on-board the International Space Station, which might impact the microgravity environment their experiments are exposed to. From the Principal Investigator Microgravity Services' web site, the principal investigator teams can monitor via a dynamic graphical display, implemented in Java, in near real time, which event(s) is/are on, such as crew activities, pumps, fans, centrifuges, compressor, crew exercise, structural modes, etc., and decide whether or not to run their experiments, whenever that is an option, based on the acceleration magnitude and frequency sensitivity associated with that experiment. This monitoring system detects primarily the vibratory disturbance sources. The system has built-in capability to detect both known

  20. Portable Water Level Monitoring System via SMS

    Directory of Open Access Journals (Sweden)

    Jomar S. Vitales

    2015-11-01

    Full Text Available Damages and lives taken by the typhoon Ondoy and other super typhoons brought the researchers to think and develop a device that warns people an hour or more than an hour before the devastating phenomena. In this project the researchers have thought of using text messaging in which the country’s leading means of communication. The development of the project was guided by the Engineering Design Cycle of Dr. Allan Cheville in his book entitled “Rocket Engineering”. The researchers have identified and used the needed materials which are suited in the intended function of the project. The project was already evaluated and had gathered a favorable response from the knowledgeable respondents in the field where the design project is intended to use. The project has a high acceptability level in the respondents’ point of view. The researchers are highly recommending the implementation of the project for a better testing in the incoming rainy season and also recommending to be placed in the Pantalan Bridge in Pantalan, Nasugbu, Batangas, Philippines. The researchers are also suggesting another study for a better water proof casing of the project.

  1. The Antarctic permafrost as a testbed for REMS (Rover Environmental Monitoring Station-Mars Science Laboratory)

    Science.gov (United States)

    Esteban, B.; Ramos, M.; Sebastián, E.; Armiens, C.; Gómez-Elvira, J.; Cabos, W.; de Pablo, M. A.

    2009-04-01

    The present climatic characteristics of Mars favor the presence of extense permafrost areas in this lonely planet. Therefore environmental parameters that are included in Martian Rover missions are also used for monitoring thermal soil surface evolution in order to study the permafrost active layer thickness and the energy balance in the soil-atmosphere boundary limit layer. The REMS (Rover Environmental Monitoring Station) is an environmental station designed by the Centro de Astrobiología (CAB- Spain) with the collaboration of national and international partners (CRISA/EADS, UPC and FMI), which is part of the payload of the MSL (Mars Science Laboratory) NASA mission to Mars (http://mars.jpl.nasa.gov/msl/overview/). This mission is expected to be launched in the final months of 2009, and mainly consists of a Rover, with a complete set of scientific instruments; the Rover will carry the biggest, most advanced suite of instruments for scientific studies ever sent to the Martian surface. Five sensors compose the REMS instrument: ground (GT-REMS) and air temperatures, wind speed and direction, pressure, humidity and ultraviolet radiation (UV-REMS). A simplified setup of the REMS was deployed on Antarctica in the surroundings of the Spanish Antarctic Stations on Livingston and Deception Islands (Maritime Antarctica), where the permafrost distribution is well-known. The aim of the experiment was to check REMS's sensors response against hard environmental conditions and calibrates their measures with standard Antarctic devices. The experimental apparatuses included some standard meteorological and thermopiles sensors corresponding to the REMS. All the sensors are mounted in a 1.8 m mast and include a Pt100 air temperature sensor with shield solar protection on the mast top, a Kipp and Zonnen CNR1 net radiometer for measuring infrared (5-50 μm) and short wave solar (305-2800 nm) radiation at 1.5 m high, GT-REMS sensor and its amplification box at 0.7 m high and finally

  2. The development of a volatile organics concentrator for use in monitoring Space Station water quality

    Science.gov (United States)

    Bodek, Itamar; Ehntholt, Daniel J.; Stolki, Thomas J.; Valentine, James R.; Trabanino, Rudy; Webb, Johanna V.; Sauer, Richard L.

    1991-01-01

    A breadboard concept of a volatile organics concentrator (VOC) is manufactured and tested for optimized water-quality analysis in a space environment. The VOC system is attached to a gas chromatograph/mass spectrometer to analyze the volatile chemicals relevant to the operation of Space Station Freedom. The preliminary tests include: (1) comparisons with analyses based on direct on-column injections of standards; (2) analyses of iodinated volatile organics; (3) comparisons of nitrogen vs helium as the chromatography carrier gas; and (4) measurements of collection efficiency. The VOC can analyze EPA method-624 analytes at comparable detection using flame-ionization detection and can analyze volatile iodinated compounds. The breadboard has good reproducibility and can use nitrogen as a carrier gas; good results are noted for the collection and concentration levels and for water removal.

  3. Evaluation of the Air Quality Monitor's Performance on the International Space Station

    Science.gov (United States)

    Limero, Thomas; Reese, Eric; Ballard, Ken; Durham, Tamara

    2010-01-01

    The Air Quality Monitor (AQM) was flown to the International Space Station (ISS) as an experiment to evaluate its potential to replace the aging Volatile Organic Analyzer (VOA), which ceased operations in August 2009. The AQM (Figure 1) is a small gas chromatography/differential mobility spectrometer (GC/DMS) manufactured by Sionex. Data was presented at last year s ISIMS conference that detailed the preparation of the AQM for flight, including instrument calibration. Furthermore, initial AQM data was compared to VOA results from simultaneous runs of the two instruments. Although comparison with VOA data provided a measure of confidence in the AQM performance, it is the comparison with results from simultaneously acquired air samples (grab sample containers-GSCs) that will define the success (or failure) of the AQM performance. This paper will update the progress in the AQM investigation by comparing AQM data to results from the analyses of GSC samples, returned from ISS. Additionally, a couple of example will illustrate the AQM s ability to detect disruptions in the spacecraft s air quality. Discussion will also focus upon a few unexpected issues that have arisen and how these will be a addressed in the final operational unit now being built.

  4. radio frequency based radio frequency based water level monitor

    African Journals Online (AJOL)

    eobe

    ABSTRACT. This paper elucidates a radio frequency (RF) based transmission and reception system used to remotely monitor and .... range the wireless can cover but in this prototype, it ... power supply to the system, the sensed water level is.

  5. UARS Particle Environment Monitor (PEM) Level 3TP V001

    Data.gov (United States)

    National Aeronautics and Space Administration — The Particle Environment Monitor (PEM) Level 3TP data product consists of daily, 65.536 second and 2.048 interval time-ordered, vertical profiles of electron and...

  6. Creation of nuclear power stations for export. Adapting a reference power station from the technical level of a national programme

    International Nuclear Information System (INIS)

    Marcaillou, J.; Haond, H.; Py, J.P.

    1977-01-01

    The recent evolution of primary energy supplies places those countries with a nuclear industry in an exporting role. Exporting countries have generally developed a limited number of national reactor types and attempt to extend their manufacture with as few changes as possible. The EDF in France is implementing an important 900-MW(e) PWR programme based on Framatome nuclear reactors, initially conceived by Westinghouse. Standardization imposes constraints, has limits, but offers incontestable advantages in terms of reliability, availability and security. These advantages were highly appreciated during the introduction into service of conventional thermal loads. Importing countries are all concerned to purchase a proven model. However, various local restrictions are often present, which are usually different from those accounted for in the export model, thus resulting in a need for modification. The different ways of considering the inescapable constraints can be analysed and their influence on the 'disfigurement' of the reactor model can be examined. Some of these constraints are connected with characteristics of the site. The nature of the soil and the seismicity influence the foundation and the depth of the installation and the choice between a foundation on antiseismic supports or structural reinforcement. The hydrology (risk of flooding or of deviation of the cold source) influences the choice between elevation of the installation and a protective dike, and also the stand-by coolant circuit. The atmospheric conditions and the temperature of cooling water influence the materials and their conditioning as well as the power level of the station. The surrounding demography influences the waste treatment systems. The characteristics of the electricity network influence the plan of the electric power supply and the conditions of operation. Finally, the characteristics of the personnel of the undertaking provide training problems. Other parameters to be taken into

  7. Temporal variability of the bioaerosol background at a subway station: concentration level, size distribution, and diversity of airborne bacteria.

    Science.gov (United States)

    Dybwad, Marius; Skogan, Gunnar; Blatny, Janet Martha

    2014-01-01

    Naturally occurring bioaerosol environments may present a challenge to biological detection-identification-monitoring (BIODIM) systems aiming at rapid and reliable warning of bioterrorism incidents. One way to improve the operational performance of BIODIM systems is to increase our understanding of relevant bioaerosol backgrounds. Subway stations are enclosed public environments which may be regarded as potential bioterrorism targets. This study provides novel information concerning the temporal variability of the concentration level, size distribution, and diversity of airborne bacteria in a Norwegian subway station. Three different air samplers were used during a 72-h sampling campaign in February 2011. The results suggested that the airborne bacterial environment was stable between days and seasons, while the intraday variability was found to be substantial, although often following a consistent diurnal pattern. The bacterial levels ranged from not detected to 10(3) CFU m(-3) and generally showed increased levels during the daytime compared to the nighttime levels, as well as during rush hours compared to non-rush hours. The airborne bacterial levels showed rapid temporal variation (up to 270-fold) on some occasions, both consistent and inconsistent with the diurnal profile. Airborne bacterium-containing particles were distributed between different sizes for particles of >1.1 μm, although ∼50% were between 1.1 and 3.3 μm. Anthropogenic activities (mainly passengers) were demonstrated as major sources of airborne bacteria and predominantly contributed 1.1- to 3.3-μm bacterium-containing particles. Our findings contribute to the development of realistic testing and evaluation schemes for BIODIM equipment by providing information that may be used to simulate operational bioaerosol backgrounds during controlled aerosol chamber-based challenge tests with biological threat agents.

  8. Temporal Variability of the Bioaerosol Background at a Subway Station: Concentration Level, Size Distribution, and Diversity of Airborne Bacteria

    Science.gov (United States)

    Dybwad, Marius; Skogan, Gunnar

    2014-01-01

    Naturally occurring bioaerosol environments may present a challenge to biological detection-identification-monitoring (BIODIM) systems aiming at rapid and reliable warning of bioterrorism incidents. One way to improve the operational performance of BIODIM systems is to increase our understanding of relevant bioaerosol backgrounds. Subway stations are enclosed public environments which may be regarded as potential bioterrorism targets. This study provides novel information concerning the temporal variability of the concentration level, size distribution, and diversity of airborne bacteria in a Norwegian subway station. Three different air samplers were used during a 72-h sampling campaign in February 2011. The results suggested that the airborne bacterial environment was stable between days and seasons, while the intraday variability was found to be substantial, although often following a consistent diurnal pattern. The bacterial levels ranged from not detected to 103 CFU m−3 and generally showed increased levels during the daytime compared to the nighttime levels, as well as during rush hours compared to non-rush hours. The airborne bacterial levels showed rapid temporal variation (up to 270-fold) on some occasions, both consistent and inconsistent with the diurnal profile. Airborne bacterium-containing particles were distributed between different sizes for particles of >1.1 μm, although ∼50% were between 1.1 and 3.3 μm. Anthropogenic activities (mainly passengers) were demonstrated as major sources of airborne bacteria and predominantly contributed 1.1- to 3.3-μm bacterium-containing particles. Our findings contribute to the development of realistic testing and evaluation schemes for BIODIM equipment by providing information that may be used to simulate operational bioaerosol backgrounds during controlled aerosol chamber-based challenge tests with biological threat agents. PMID:24162566

  9. Seasonal variation of seismic ambient noise level at King Sejong Station, Antarctica

    Science.gov (United States)

    Lee, W.; Sheen, D.; Seo, K.; Yun, S.

    2009-12-01

    The generation of the secondary- or double-frequency (DF) microseisms with dominant frequencies between 0.1 and 0.5 Hz has been explained by nonlinear second-order pressure perturbations on the ocean bottom due to the interference of two ocean waves of equal wavelengths traveling in opposite directions. Korea Polar Research Institute (KOPRI) has been operating a broadband seismic station (KSJ1) at King George Island (KGI), Antarctica, since 2001. Examining the ambient seismic noise level for the period from 2006 to 2008 at KSJ1, we found a significant seasonal variation in the frequency range 0.1-0.5 Hz. Correlation of the DF peaks with significant ocean wave height and peak wave period models indicates that the oceanic infragravity waves in the Drake Passage is a possible source to excite the DF microseisms at KGI. Location of King Sejong Station, Antarctica Seasonal variations of DF peak, significant wave height, and peak wave period

  10. Level of service for pedestrian movement towards the performance of passenger information in public transport stations in Klang Valley

    Science.gov (United States)

    Ramli, M. Z.; Hanipah, M. H.; Lee, L. G.; Loo, K. F.; Wong, J. K.; Zawawi, M. H.; Fuad, N. F. S.

    2017-09-01

    Rapid growth in car ownership in Malaysia plays a major role to traffic congestion. Hence, public transportation is crucial to cater the residents in high-density area especially in Klang Valley. Signage information in public transport station is one of an important passenger information system. Poor placement of sign information will decrease the efficiency of passenger flow and caused congestion in the station. Passenger information system is very useful for trip planning and decision making. Therefore, it is interesting to study the performance of passenger information system in focusing the movement behavior of pedestrian at non-peak period. Thus, the study on pedestrian movement during non-peak period on weekdays and weekends in mass transit stations and bus transit stations in Klang Valley was carried out by using video observation. The observation of the pedestrian movement was made in Mass Transit Station 1 in the middle of Kuala Lumpur and Mass Transit Station 2 in southern of Kuala Lumpur. The other site was focused at Bus Transit Station 1 in Putrajaya and Bus Transit Station 2 in Kajang. Findings shown that Mass Transit Station 1 having the best facility in terms of passenger information which the level of service obtained is LOS A, while the lowest level of service which is LOS E was obtained in Bus Transit Station 2.

  11. New seismic monitoring observation system and data accessibility at Syowa Station

    Directory of Open Access Journals (Sweden)

    Masaki Kanao

    1999-03-01

    Full Text Available The seismic observation system at Syowa Station, East Antarctica was fully replaced in the wintering season of the 38th Japanese Antarctic Research Expedition (JARE-38 in 1996-1998. The old seismographic vault constructed in 1970 was closed at the end of JARE-38 because of cumulative damage to the inner side of the vault by continuous flowing in of water from walls in summer and its freezing in winter. All the seismometers were moved to a new seismographic hut (69°00′24.0″S, 39°35′06.0″E and 20m above mean sea level in April 1997. Seismic signals of the short-period (HES and broadband (STS-1 seismometers in the new hut are transmitted to the Earth Science Laboratory (ESL via analog cable 600m in length. The new acquisition system was installed in the ESL with 6-channel 24-bit A/D converters for both sensor signals. All digitized data are automatically transmitted from the A/D converter to a workstation via TCP/IP protocol. After parallel observations with the old acquisition system by personal computers and the new system during the wintering season of JARE-38,the main system was changed to the new one, which has some advantages for both the reduction of daily maintenance efforts and the data transport/communication processes via Internet by use of LAN at the station. In this report, details of the new seismographic hut and the recording system are described. Additionally, the seismic data accessibility for public use, including Internet service, is described.

  12. Radiation monitoring network in Poland

    International Nuclear Information System (INIS)

    Grabowski, D.; Kurowski, W.; Muszynski, W.; Rubel, B.; Smagala, G.; Swietochowska, J.

    2001-01-01

    In Poland the radioactive contamination of the environment and food has been controlled since the early sixties by the Service for Measurements of Radioactive Contamination (SPSP). The service comprises a network of measuring stations and the Centre of Radioactive Contamination Measurements (COPSP). Actually, there are 100 measurement stations. The main task of such station is systematic measurement of radioactivity level in samples of environment components and food. Nine stations of SPSP acting within meteorological stations, ten stations of low level air radioactivity measurements (Aerosols Sampling Stations-500) and eleven permanent monitoring stations (PMS) form the radiation monitoring warning system in Poland. (author)

  13. Lunar Atmosphere Probe Station: A Proof-of-Concept Instrument Package for Monitoring the Lunar Atmosphere

    Science.gov (United States)

    Lazio, J.; Jones, D. L.; MacDowall, R. J.; Stewart, K. P.; Burns, J. O.; Farrell, W. M.; Giersch, L.; O'Dwyer, I. J.; Hicks, B. C.; Polisensky, E. J.; Hartman, J. M.; Nesnas, I.; Weiler, K.; Kasper, J. C.

    2013-12-01

    The lunar exosphere is the exemplar of a plasma near the surface of an airless body. Exposed to both the solar and interstellar radiation fields, the lunar exosphere is mostly ionized, and enduring questions regarding its properties include its density and vertical extent, the extent of contributions from volatile outgassing from the Moon, and its behavior over time, including response to the solar wind and modification by landers. Relative ionospheric measurements (riometry) are based on the simple physical principle that electromagnetic waves cannot propagate through a partially or fully ionized medium below the plasma frequency, and riometers have been deployed on the Earth in numerous remote and hostile environments. A multi-frequency riometer on the lunar surface would be able to monitor, *in situ*, the vertical extent of the lunar exosphere over time. We provide an update on a concept for a riometer implemented as a secondary science payload on future lunar landers, such as those recommended in the recent Planetary Sciences Decadal Survey report or commercial ventures. The instrument concept is simple, consisting of an antenna implemented as a metal deposited on polyimide film and receiver. We illustrate various deployment mechanisms and performance of a prototype in increasing lunar analog conditions. While the prime mission of such a riometer would be probing the lunar exosphere, our concept would also be capable to measuring the properties of dust impactors. The Lunar University Network for Astrophysical Research consortium is funded by the NASA Lunar Science Institute to investigate concepts for astrophysical observatories on the Moon. Part of this research was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under a contract with NASA. Artist's impression of the Lunar Atmosphere Probe Station.

  14. Elemental composition of aerosol particles from two atmospheric monitoring stations in the Amazon Basin

    International Nuclear Information System (INIS)

    Artaxo, P.; Gerab, F.; Rabello, M.L.C.

    1993-01-01

    One key region for the study of processes that are changing the composition of the global atmosphere is the Amazon Basin tropical rain forest. The high rate of deforestation and biomass burning is emitting large amounts of gases and fine-mode aerosol particles to the global atmosphere. Two background monitoring stations are operating continuously measuring aerosol composition, at Cuiaba, and Serra do Navio. Fine- and coarse-mode aerosol particles are being collected using stacked filter units. Particle induced X-ray emission (PIXE) was used to measure concentrations of up to 21 elements: Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Se, Br, Rb, Sr, Zr, and Pb. The elemental composition was measured at the new PIXE facility from the University of Sao Paulo, using a dedicated 5SDH tandem Pelletron nuclear accelerator. Absolute principal factor analysis (APFA) has derived absolute elemental source profiles. At the Serra do Navio sampling site a very clean background aerosol is being observed. Biogenic aerosol dominates the fine-mode mass concentration, with the presence of K, P, S, Cl, Zn, Br, and FPM. Three components dominate the aerosol composition: Soil dust particles, the natural biogenic release by the forest, and a marine aerosol component. At the Cuiaba site, during the dry season, a strong component of biomass burning is observed. An aerosol mass concentration up to 120 μg/m 3 was measured. APFA showed three components: Soil dust (Al, Ca, Ti, Mn, Fe), biomass burning (soot, FPM, K, Cl) and natural biogenic particles (K, S, Ca, Mn, Zn). The fine-mode biogenic component of both sites shows remarkable similarities, although the two sampling sites are 3000 km apart. Several essential plant nutrients like P, K, S, Ca, Ni and others are transported in the atmosphere as a result of biomass burning processes. (orig.)

  15. Coastwide Reference Monitoring System (CRMS) Vegetation Volume Index: An assessment tool for marsh habitat focused on the three-dimensional structure at CRMS vegetation monitoring stations

    Science.gov (United States)

    Wood, William B.; Visser, Jenneke M.; Piazza, Sarai C.; Sharp, Leigh A.; Hundy, Laura C.; McGinnis, Tommy E.

    2015-12-04

    A Vegetation Volume (VV) variable and Vegetation Volume Index (VVI) have been developed for the Coastwide Reference Monitoring System (CRMS). The VV is a measure of the amount of three-dimensional vegetative structure present at each CRMS site and is based on vegetation data collected annually. The VV uses 10 stations per CRMS site to quantify four vegetation layers: carpet, herbaceous, shrub, and tree. For each layer an overall live vegetation percent cover and height are collected to create a layer volume; the individual layer volumes are then summed to generate a site vegetation volume profile. The VV uses the two-dimensional area of live vegetative cover (in square meters) multiplied by the height (in meters) of each layer to produce a volume (in cubic meters) for each layer present in a 2-meter by 2-meter station. These layers are additive, yielding a total volume for each of the 10 herbaceous vegetation stations and an overall CRMS marsh site average.

  16. Thermal monitoring of hydrothermal activity by permanent infrared automatic stations: Results obtained at Solfatara di Pozzuoli, Campi Flegrei (Italy)

    Science.gov (United States)

    Chiodini, G.; Vilardo, G.; Augusti, V.; Granieri, D.; Caliro, S.; Minopoli, C.; Terranova, C.

    2007-12-01

    A permanent automatic infrared (IR) station was installed at Solfatara crater, the most active zone of Campi Flegrei caldera. After a positive in situ calibration of the IR camera, we analyze 2175 thermal IR images of the same scene from 2004 to 2007. The scene includes a portion of the steam heated hot soils of Solfatara. The experiment was initiated to detect and quantify temperature changes of the shallow thermal structure of a quiescent volcano such as Solfatara over long periods. Ambient temperature is the main parameter affecting IR temperatures, while air humidity and rain control image quality. A geometric correction of the images was necessary to remove the effects of slow movement of the camera. After a suitable correction the images give a reliable and detailed picture of the temperature changes, over the period October 2004 to January 2007, which suggests that origin of the changes were linked to anthropogenic activity, vegetation growth, and the increase of the flux of hydrothermal fluids in the area of the hottest fumaroles. Two positive temperature anomalies were registered after the occurrence of two seismic swarms which affected the hydrothermal system of Solfatara in October 2005 and October 2006. It is worth noting that these signs were detected in a system characterized by a low level of activity with respect to systems affected by real volcanic crisis where more spectacular results will be expected. Results of the experiment show that this kind of monitoring system can be a suitable tool for volcanic surveillance.

  17. Use of a microprocessor in a remote working level monitor

    International Nuclear Information System (INIS)

    Keffe, D.J.; McDowell, W.P.; Groer, P.G.

    1975-01-01

    A remote working level monitor was designed to measure short-lived radon-daughter concentrations in sealed chambers having potentially high radiation levels (up to 2000 WL). The system is comprised of surface barrier detectors, multiplexer and buffers, microprocessor and teletype

  18. DOSIS & DOSIS 3D: long-term dose monitoring onboard the Columbus Laboratory of the International Space Station (ISS

    Directory of Open Access Journals (Sweden)

    Berger Thomas

    2016-01-01

    Full Text Available The radiation environment encountered in space differs in nature from that on Earth, consisting mostly of highly energetic ions from protons up to iron, resulting in radiation levels far exceeding the ones present on Earth for occupational radiation workers. Since the beginning of the space era, the radiation exposure during space missions has been monitored with various active and passive radiation instruments. Also onboard the International Space Station (ISS, a number of area monitoring devices provide data related to the spatial and temporal variation of the radiation field in and outside the ISS. The aim of the DOSIS (2009–2011 and the DOSIS 3D (2012–ongoing experiments was and is to measure the radiation environment within the European Columbus Laboratory of the ISS. These measurements are, on the one hand, performed with passive radiation detectors mounted at 11 locations within Columbus for the determination of the spatial distribution of the radiation field parameters and, on the other, with two active radiation detectors mounted at a fixed position inside Columbus for the determination of the temporal variation of the radiation field parameters. Data measured with passive radiation detectors showed that the absorbed dose values inside the Columbus Laboratory follow a pattern, based on the local shielding configuration of the radiation detectors, with minimum dose values observed in the year 2010 of 195–270 μGy/day and maximum values observed in the year 2012 with values ranging from 260 to 360 μGy/day. The absorbed dose is modulated by (a the variation in solar activity and (b the changes in ISS altitude.

  19. Monitoring of raptors and their contamination levels in Norway.

    Science.gov (United States)

    Gjershaug, Jan Ove; Kålås, John Atle; Nygård, Torgeir; Herzke, Dorte; Folkestad, Alv Ottar

    2008-09-01

    This article summarizes results from raptor monitoring and contamination studies in Norway of the golden eagle, gyrfalcon, white-tailed sea eagle, osprey, peregrine, and merlin. Golden eagle and gyrfalcon populations have been monitored since 1990 as part of the "Monitoring Programme for Terrestrial Ecosystems" (TOV). No long-term trend in the population size or productivity of golden eagle has been shown in any of the 5 study areas. The reproductive output of gyrfalcon is monitored in 3 areas. It is positively correlated with the populations of its main prey species, the rock ptarmigan and the willow ptarmigan. The white-tailed sea eagle population has been monitored since 1974 by the Norwegian Ornithological Society, and the population is increasing. The levels of pesticides and polychlorinated biphenyls are low in the eggs of both the golden eagle and the gyrfalcon, but elevated levels and effects on reproduction have been indicated for a coastal subpopulation of golden eagle. The pollutant levels in white-tailed sea eagle are lower than in the Baltic population of sea eagles, and shell thinning was never severe overall, but individual eggs have contained pollutant concentrations above critical levels. The levels of pollutants in the bird-eating falcons, peregrine, and merlin were higher than in other species. New emerging pollutants, like brominated diphenylethers and perfluorinated organic compounds, could be detected in all species. By incorporating available published and unpublished data, we were able to produce time trends for pollutants and shell thickness over 4 decades.

  20. Advanced I and C system of security level for nuclear power station

    International Nuclear Information System (INIS)

    Liu Yanyang

    2001-01-01

    Advanced I and C system of security level using for PWR developed by Framatome and Schneider collective, SPINLINE3, are introduced. The technology is used to outside reactor nuclear measurement system in Qinshan II period. It's succeed benefits by Framatome and Schneider's more years development experience in nuclear power station digitallization security level I and C system field, which improve security and reliability of PWR, and, easy operation and maintains. SPINLINE3 based on digitallization and modularization technical proposal, and covered entireness reactor protect system and correlative control system. The paper also introduce CLARISSE (computer aided design aid) and SCADE (embedded software aid) for developing SPINLINE3. SPINLINE3 fills correlative IS and rule, based on software and hardware unit which certificate and launch into operation. After brief review of Framatome and Schneider's experience, the paper are introducing design guideline, application technology and how to fill demand of security level I and C system

  1. Forecasting Sea Water Levels at Mukho Station, South Korea Using Soft Computing Techniques

    Directory of Open Access Journals (Sweden)

    Ozgur Kisi

    2014-12-01

    Full Text Available The accuracy of three different data-driven methods, namely, Gene Expression Programming (GEP, Adaptive Neuro-Fuzzy Inference System (ANFIS and Artificial Neural Networks (ANN, is investigated for hourly sea water level prediction at the Mukho Station in the East Sea (Sea of Japan. Current and four previous level measurements are used as input variables to predict sea water levels up to 1, 24, 48, 72, 96 and 120 hours ahead. Three statistical evaluation parameters, namely, the correlation coefficient, the root mean square error and the scatter index are used to assess how the models perform. Investigation results indicate that, when compared to measurements, for +1h prediction interval, all three models perform well (with average values of R = 0.993, RMSE = 1.3 cm and SI = 0.04, with slightly better results produced by the ANNs and ANFIS, while increasing the prediction interval degrades model performance.

  2. Time series for water levels in virtual gauge stations in the Amazon basin using satellite radar altimetry

    Directory of Open Access Journals (Sweden)

    Juan Gabriel León Hernández

    2009-01-01

    Full Text Available Using satellite altimeter radar technology for monitoring changes in water levels at continental scale is a relatively recent ad- vance. Several studies have demonstrated the interest being shown in applying this technology to monitoring the hydrographic patterns of large-scale basins worldwide. The current study presents the inference of time series representing changes in water le- vel for bodies of water by defining virtual gauge stations deduced for two very different rivers in terms of their biophysical and to- pographic characteristics; the two rivers were the Rio Negro in the Brazilian Amazon Basin and the Caqueta River on the Colombian side. The differences between the two rivers revealed the limits of satellite radar altimeter when applied to continental waters (±20cm and ±40 cm precision for Río Negro and Río Caquetá, respectively. However, applying this technology seems very promising, since new missions have been scheduled to be put into orbit by the end of 2008.

  3. SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION PROJECT

    Energy Technology Data Exchange (ETDEWEB)

    Paul Higley; J. Robert Woolsey; Ralph Goodman; Vernon Asper; Boris Mizaikoff; Angela Davis; Bob A. Hardage; Jeffrey Chanton; Rudy Rogers

    2006-03-01

    The Gulf of Mexico Hydrates Research Consortium was established in 1999 to assemble leaders in gas hydrates research. The group is administered by the Center for Marine Resources and Environmental Technology, CMRET, at the University of Mississippi. The primary objective of the group is to design and emplace a remote monitoring station or sea floor observatory on the sea floor in the northern Gulf of Mexico by the year 2005, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission necessitates assembling a station that will monitor physical and chemical parameters of the sea water and sea floor sediments on a more-or-less continuous basis over an extended period of time. Development of the station has always included the possibility of expanding its capabilities to include biological monitoring, as a means of assessing environmental health. This possibility has recently received increased attention and the group of researchers working on the station has expanded to include several microbial biologists. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in this relatively new research arena. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. Initial components of the observatory, a probe that collects pore-fluid samples and another that records sea floor temperatures, were deployed in Mississippi Canyon 118 in May of 2005. Follow-up deployments are planned for fall 2005 and center about the use of the vessel M/V Ocean Quest and its two manned submersibles. The subs will be used to effect bottom surveys, emplace sensors and sea floor experiments and make connections between sensor data loggers and the integrated data power unit (IDP). Station/observatory completion is anticipated for 2007 following the

  4. Low level neutron monitoring using high pressure 3He detectors

    International Nuclear Information System (INIS)

    Pszona, S.

    1995-01-01

    Three detectors, two spherical proportional counters and an ionisation chamber, all filled with 3 He to pressures of 160 kPa, 325 kPa and 1 MPa respectively have been experimentally studied with respect to their use for low level neutron monitoring. The ambient dose equivalent responses and the energy resolutions of these detectors have been determined. It is shown that spectral analysis of the signals from these detectors not only gives high sensitivity with regard to ambient dose equivalent but also improves the quality of the measurements. A special instrumentation for low level neutron monitoring is described in which a quality control method has been implemented. (Author)

  5. National Coral Reef Monitoring Program: Benthic Images Collected from Climate Stations across American Samoa in 2015

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Photoquadrat benthic images were collected at NCRMP climate stations and permanent sites identified by the Ocean and Climate Change team across American Samoa in...

  6. Monitoring of volatile organic compounds (VOCs) from an oil and gas station in northwest China for 1 year

    Science.gov (United States)

    Zheng, Huang; Kong, Shaofei; Xing, Xinli; Mao, Yao; Hu, Tianpeng; Ding, Yang; Li, Gang; Liu, Dantong; Li, Shuanglin; Qi, Shihua

    2018-04-01

    Oil and natural gas are important for energy supply around the world. The exploring, drilling, transportation and processing in oil and gas regions can release a lot of volatile organic compounds (VOCs). To understand the VOC levels, compositions and sources in such regions, an oil and gas station in northwest China was chosen as the research site and 57 VOCs designated as the photochemical precursors were continuously measured for an entire year (September 2014-August 2015) using an online monitoring system. The average concentration of total VOCs was 297 ± 372 ppbv and the main contributor was alkanes, accounting for 87.5 % of the total VOCs. According to the propylene-equivalent concentration and maximum incremental reactivity methods, alkanes were identified as the most important VOC groups for the ozone formation potential. Positive matrix factorization (PMF) analysis showed that the annual average contributions from natural gas, fuel evaporation, combustion sources, oil refining processes and asphalt (anthropogenic and natural sources) to the total VOCs were 62.6 ± 3.04, 21.5 ± .99, 10.9 ± 1.57, 3.8 ± 0.50 and 1.3 ± 0.69 %, respectively. The five identified VOC sources exhibited various diurnal patterns due to their different emission patterns and the impact of meteorological parameters. Potential source contribution function (PSCF) and concentration-weighted trajectory (CWT) models based on backward trajectory analysis indicated that the five identified sources had similar geographic origins. Raster analysis based on CWT analysis indicated that the local emissions contributed 48.4-74.6 % to the total VOCs. Based on the high-resolution observation data, this study clearly described and analyzed the temporal variation in VOC emission characteristics at a typical oil and gas field, which exhibited different VOC levels, compositions and origins compared with those in urban and industrial areas.

  7. Monitoring of geological repositories for high level radioactive waste

    International Nuclear Information System (INIS)

    2001-04-01

    Geological repositories for disposal of high level radioactive waste are designed to provide isolation of the waste from human environment for many thousands of years. This report discusses the possible purposes for monitoring geological repositories at the different stages of a repository programme, the use that may be made of the information obtained and the techniques that might be applied. This report focuses on the different objectives that monitoring might have at various stages of a programme, from the initiation of work on a candidate site, to the period after repository closure. Each objective may require somewhat different types of information, or may use the same information in different ways. Having evaluated monitoring requirements, the report concludes with a brief evaluation of available monitoring techniques

  8. Investigation and analysis of leveling deformation anomaly at Daixian station in Shanxi

    Directory of Open Access Journals (Sweden)

    Xiuwen Wang

    2017-03-01

    Full Text Available The leveling measurements at Daixian station appeared increasing trend since March 25, 2013, which is credible, showing normal fault activity. According to the environmental survey, it contains some interference factors: first, the wind is big when the leveling measures in the afternoon, which has certain influence on the measurement results, but the impact is random and should be near the base value and not appear a trend. Second, the point BM3 was maintained during Sep. to Oct. in 2012 and occurred cracks in 2013, showing that the poor stability around the point. In addition, the change of recorded program is only to change the way of data record and can not affect the observation results during the same period.

  9. GFR and Blood Lead Levels in Gas Station Workers Based on δ-Alad Gene Polymorphisms

    Directory of Open Access Journals (Sweden)

    Lantip Rujito

    2015-04-01

    showed that the proportion of ALAD genotype for ALAD 1-1, 1-2 and 2-2 were 94.7%, 5.3%, and 0% respectively. The mean of serum levels in homozygous 1-1 was 15.94 ppb and heterozygote 1-2 was 1.15 ppb. GFR of participants ranged from 71.11 mL/min to 185.20 mL/min with a mean of 117.34mL/min. There was no correlation between serum Pb and GFR (p = 0.19. Study also could not determine the correlation between GFR and ALAD gene Polymorphism. Discussion: Study then concluded that there was no correlation between blood lead levels in the GFR on each δ-ALAD genotypes. Keywords: Lead intoxication, GFR, δ-ALAD, gas station workers

  10. Radioactivity level of the ambient environment of Anren bone-coal power station

    International Nuclear Information System (INIS)

    Ye Jida; Liu Hongshi; Wu Zongmei; Wu Xiaofei

    2002-01-01

    The radioactivity level of the ambient environment of Anren Bone-coal Power Station (BCPS) was investigated systematically. The γ radiation dose rate level in the environment, the content of 238 U and 226 Ra in the ambient soil and the farmland in the direction of downwind, the concentrations of 238 U, 232 Th, 226 Ra, 40 K and 222 Rn, as well as α potential energy in air, and the concentrations of natural U and Th in effluent are all higher than the corresponding values of the reference site. The additional annual effective dose equivalent to the residents living in the houses made of bone-coal cinder brick is 2.7 mSv

  11. Comparing facility-level methane emission rate estimates at natural gas gathering and boosting stations

    Directory of Open Access Journals (Sweden)

    Timothy L. Vaughn

    2017-11-01

    Full Text Available Coordinated dual-tracer, aircraft-based, and direct component-level measurements were made at midstream natural gas gathering and boosting stations in the Fayetteville shale (Arkansas, USA. On-site component-level measurements were combined with engineering estimates to generate comprehensive facility-level methane emission rate estimates (“study on-site estimates (SOE” comparable to tracer and aircraft measurements. Combustion slip (unburned fuel entrained in compressor engine exhaust, which was calculated based on 111 recent measurements of representative compressor engines, accounts for an estimated 75% of cumulative SOEs at gathering stations included in comparisons. Measured methane emissions from regenerator vents on glycol dehydrator units were substantially larger than predicted by modelling software; the contribution of dehydrator regenerator vents to the cumulative SOE would increase from 1% to 10% if based on direct measurements. Concurrent measurements at 14 normally-operating facilities show relative agreement between tracer and SOE, but indicate that tracer measurements estimate lower emissions (regression of tracer to SOE = 0.91 (95% CI = 0.83–0.99, R2 = 0.89. Tracer and SOE 95% confidence intervals overlap at 11/14 facilities. Contemporaneous measurements at six facilities suggest that aircraft measurements estimate higher emissions than SOE. Aircraft and study on-site estimate 95% confidence intervals overlap at 3/6 facilities. The average facility level emission rate (FLER estimated by tracer measurements in this study is 17–73% higher than a prior national study by Marchese et al.

  12. Simulations of the neutron energy-spectra at the Olympus Gate Environmental Monitoring Station due to historical Bevatron operations

    International Nuclear Information System (INIS)

    Donahue, R.J.; Thomas, R.H.; Zeman, G.H.

    2001-01-01

    and newer sets of conversion coefficients were applied to the calculated neutron energy spectra. It is concluded by this independent assessment that early dose equivalent estimates were conservative by at least a factor of 4. This reduction results from three factors: (1) a better understanding of the neutron energy spectrum at the laboratory site boundary (factor of ∼2); (2) revised conversion coefficients (factor of ∼2); and (3) the intrinsic conservatism of the reported dose equivalents (factor of ∼2). An investigation of the detector response to neutrons strongly suggests an additional systematic overestimation of the total neutron fluence by the routinely used environmental monitors. The influence of the ground on detector response has also been studied. Based on IAEA response functions, when calibrated with standard 239 PuBe neutron sources, 6-inch dia. spherical polyethylene moderators would have overestimated the dose equivalents in the accelerator spectra by a factor of about 1.3. It was also possible to show that at locations near the Olympus Gate Environmental Monitoring Station radiation levels at places not in direct view of the Bevatron were further reduced by a factor of about 2 because skyshine contributed about half the total dose equivalent

  13. Integrating working level monitor EML Type TF-11

    International Nuclear Information System (INIS)

    Latner, N.; Watnick, S.; Graveson, R.T.

    1981-01-01

    A time-integrating working level radiation monitor is described. The purpose of the instrument is the evaluation of the alpha emission from radon and its daughter products. It has been designed to be virtually silent in operation, making it suitable for residential studies

  14. Radiation levels from computer monitor screens within Benue State ...

    African Journals Online (AJOL)

    Investigation of possible presence of soft X-ray levels from Computer Screens at distances of 0.5m and 1.0m was carried out within Benue State University, Makurdi, using ten different monitor models. Radiation measurement was carried out using a portable digital radiation meter, INSPECTOR 06250 (SE international Inc.

  15. Human-factors-based implementation of the remote characterization system high-level control station

    International Nuclear Information System (INIS)

    Noakes, M.W.; Richardson, B.S.; Rowe, J.C.; Draper, J.V.; Sandness, G.R.

    1993-01-01

    The detection and characterization of buried objects and materials is an important first step in the restoration of the numerous US Department of Energy (DOE) and US Department of Defense waste disposal sites. DOE, through its Environmental Restoration and Waste Management Robotics and Technology Development Program, has developed the Remote Characterization System (RCS) to address the needs of remote subsurfacecharacterization. The RCS consists of a low-metal-content (low-metallic-signature) remotely piloted vehicle, a high-level control station (HLCS) where operators can remotely control the vehicle and analyze real-time data from sensors, and an array of sensors that can be chosen to meet the survey task at hand. Communication between the vehicle and the base station is handled by a radio link. Site mapping is made possible through the use of geopositioning satellite data. The primary mode of vehicle operation is teleoperation, but provision has been made for semiautonomous or supervisory control that allows for automated sitesurvey on simple sites. Data analysis and display is supported for both real-time observation and postprocessing of data. The particular emphasis of this paper documents the human-factors-based design influences on the HLCS and describes the design in detail

  16. Water level measurement system in reactor pressure vessel of BWR and hydrogen concentration monitoring system for severe accident

    International Nuclear Information System (INIS)

    Kuroda, Hidehiko; Okazaki, Koki; Shiraishi, Fujio; Kenjyo, Hiroaki; Isoda, Koichiro

    2013-01-01

    TEPCO's Fukushima Daiichi Nuclear Power Station Accident caused severe accident to lose functions of many instrumentation systems. As a result, many important plant parameters couldn't be monitored. In order to monitor plant parameters in the case of severe accident, new instrumentation systems available in the severe conditions are being developed. Water level in reactor pressure vessel and hydrogen concentration in primary containment vessel are one of the most important parameters. Performance test results about water level measurement sensor and hydrogen sensor in severe environmental conditions are described. (author)

  17. Present day geodynamics in Iceland monitored by a permanent network of continuous GPS stations

    Science.gov (United States)

    Völksen, Christof; Árnadóttir, Thóra; Geirsson, Halldór; Valsson, Guðmundur

    2009-12-01

    Iceland is located on the Mid-Atlantic Ridge and thereby offers a rare opportunity to study crustal movements at a divergent plate boundary. Iceland is not only characterized by the divergence of the Eurasian and North American Plates, as several active volcanoes are located on the island. Moderate size earthquakes occur in the transform zones, causing measurable crustal deformation. In 1999 the installation of a permanent network of continuous GPS stations (ISGPS) was initiated in order to observe deformation due to unrest in the Hengill volcanic system and at the Katla volcano. The ISGPS network has been enlarged over the years and consists today of more than 25 CGPS stations. Most of the stations are located along the plate boundary, where most of the active deformation takes place. Uplift due to post-glacial rebound due to the melting of the largest glacier in Europe, Vatnajökull, is also detected by the ISGPS network. This study presents results from analysis of 9 years of data from the ISGPS network, in the global reference frame PDR05, which has been evaluated by the Potsdam-Dresden-Reprocessing group with reprocessed GPS data only. We thus determine subsidence or land uplift in a global frame. The horizontal station velocities clearly show spreading across the plate boundary of about 20 mm/a. Stations in the vicinity of the glacier Vatnajökull indicate uplift in the range of 12 mm/a, while a station in the central part of Iceland shows uplift rates of about 25 mm/a. Tide gauge readings in Reykjavik and current subsidence rates observed with CGPS agree also quite well.

  18. Level monitoring system with pulsating sensor—Application to online level monitoring of dashpots in a fast breeder reactor

    Energy Technology Data Exchange (ETDEWEB)

    Malathi, N.; Sahoo, P., E-mail: sahoop@igcar.gov.in; Ananthanarayanan, R.; Murali, N. [Real Time Systems Division, Electronics, Instrumentation and Radiological Safety Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603102 (India)

    2015-02-15

    An innovative continuous type liquid level monitoring system constructed by using a new class of sensor, viz., pulsating sensor, is presented. This device is of industrial grade and it is exclusively used for level monitoring of any non conducting liquid. This instrument of unique design is suitable for high resolution online monitoring of oil level in dashpots of a sodium-cooled fast breeder reactor. The sensing probe is of capacitance type robust probe consisting of a number of rectangular mirror polished stainless steel (SS-304) plates separated with uniform gaps. The performance of this novel instrument has been thoroughly investigated. The precision, sensitivity, response time, and the lowest detection limit in measurement using this device are <0.01 mm, ∼100 Hz/mm, ∼1 s, and ∼0.03 mm, respectively. The influence of temperature on liquid level is studied and the temperature compensation is provided in the instrument. The instrument qualified all recommended tests, such as environmental, electromagnetic interference and electromagnetic compatibility, and seismic tests prior to its deployment in nuclear reactor. With the evolution of this level measurement approach, it is possible to provide dashpot oil level sensors in fast breeder reactor for the first time for continuous measurement of oil level in dashpots of Control and Safety Rod Drive Mechanism during reactor operation.

  19. A level III PSA for the inherently safe CAREM-25 nuclear power station

    International Nuclear Information System (INIS)

    Baron, Jorge H.; Nunez McLeod, J.; Rivera, S.S.

    2000-01-01

    A Level III PSA has been performed for the inherently safe CAREM-25 nuclear power station, as a requirement for licensing according to argentinian regulations. The CAREM-25 project is still at a detailed design state, therefore only internal events have been considered, and a representative site has been assumed for dose estimations. Several conservative hypothesis have been formulated, but even so an overall core melt frequency of 2.3E -5 per reactor year has been obtained. The risk estimations comply with the regulations. The risk values obtained are compared to the 700MW(e) nuclear power plant Atucha II PSA result, showing an effective risk reduction not only in the severe accident probability but alto in the consequence component of the risk estimation. (author)

  20. Meteorological and hydrographic monitoring data collected at Dauphin Island Station in Alabama from 1999-11-06 to 2001-03-01 (NODC Accession 0122658)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Meteorological and hydrographic data were collected from a monitoring station on Dauphin Island from Nov 1999 to Feb 2001. Variables measured include air...

  1. Estimation of background noise level on seismic station using statistical analysis for improved analysis accuracy

    Science.gov (United States)

    Han, S. M.; Hahm, I.

    2015-12-01

    We evaluated the background noise level of seismic stations in order to collect the observation data of high quality and produce accurate seismic information. Determining of the background noise level was used PSD (Power Spectral Density) method by McNamara and Buland (2004) in this study. This method that used long-term data is influenced by not only innate electronic noise of sensor and a pulse wave resulting from stabilizing but also missing data and controlled by the specified frequency which is affected by the irregular signals without site characteristics. It is hard and inefficient to implement process that filters out the abnormal signal within the automated system. To solve these problems, we devised a method for extracting the data which normally distributed with 90 to 99% confidence intervals at each period. The availability of the method was verified using 62-seismic stations with broadband and short-period sensors operated by the KMA (Korea Meteorological Administration). Evaluation standards were NHNM (New High Noise Model) and NLNM (New Low Noise Model) published by the USGS (United States Geological Survey). It was designed based on the western United States. However, Korean Peninsula surrounded by the ocean on three sides has a complicated geological structure and a high population density. So, we re-designed an appropriate model in Korean peninsula by statistically combined result. The important feature is that secondary-microseism peak appeared at a higher frequency band. Acknowledgements: This research was carried out as a part of "Research for the Meteorological and Earthquake Observation Technology and Its Application" supported by the 2015 National Institute of Meteorological Research (NIMR) in the Korea Meteorological Administration.

  2. Ground level and Lidar monitoring of volcanic dust and dust from Patagonia

    Science.gov (United States)

    Otero, L. A.; Losno, R.; Salvador, J. O.; Journet, E.; Qu, Z.; Triquet, S.; Monna, F.; Balkanski, Y.; Bulnes, D.; Ristori, P. R.; Quel, E. J.

    2013-05-01

    A combined approach including ground level aerosol sampling, lidar and sunphotometer measurements is used to monitor suspended particles in the atmosphere at several sites in Patagonia. Motivated by the Puyehue volcanic eruption in June 2011 two aerosol monitoring stations with several passive and active instruments were installed in Bariloche and Comodoro Rivadavia. The main goal which is to monitor ground lifted and transported ashes and dust involving danger to civil aviation, is achieved by measuring continuously aerosol concentration at ground level and aerosol vertical distribution using lidar. In addition, starting from December 2011, continuous series of weekly accumulated aerosol concentrations at Rio Gallegos are being measured to study the impact of Patagonian dust over the open ocean on phytoplankton primary productivity and CO2 removal. These measurements are going to be coupled with LIDAR monitoring and a dust optical response models to test if aerosol extrapolation can be done from the ground to the top of the layer. Laboratory chemical analysis of the aerosols will include elemental composition, solubilisation kinetic and mineralogical determination. Expected deliverables for this study is the estimation of the amount of dust exported from Patagonia towards the South Atlantic, its chemical properties, including bioavailability simulation, from model and comparison to experimental measurements.

  3. Numerical modeling and monitoring analysis of Heroísmo station, Metro do Porto

    DEFF Research Database (Denmark)

    Ferreira, P.; Sousa, T.; Silva, P.

    2007-01-01

    Metro do Porto is a major light rail infrastructure built in the city of Porto and surrounding municipalities. In Porto's downtown, classified by UNESCO as World Heritage, the metro was built underground. From a technical point of view, one of the most challenging underground metro stations due t...

  4. CO2 Monitoring and Background Mole Fraction at Zhongshan Station, Antarctica

    Directory of Open Access Journals (Sweden)

    Yulong Sun

    2014-09-01

    Full Text Available Background CO2 mole fraction and seasonal variations, measured at Zhongshan station, Antarctica, for 2010 through 2013, exhibit the expected lowest mole fraction in March with a peak in November. Irrespective of wind direction, the mole fraction of CO2 distributes evenly after polluted air from station operations is removed from the data sets. The daily range of average CO2 mole fraction in all four seasons is small. The monthly mean CO2 mole fraction at Zhongshan station is similar to that of other stations in Antarctica, with seasonal CO2 amplitudes in the order of 384–392 µmol∙mol−1. The annual increase in recent years is about 2 µmol∙mol−1∙yr−1. There is no appreciable difference between CO2 mole fractions around the coast of Antarctica and in the interior, showing that CO2 observed in Antarctica has been fully mixed in the atmosphere as it moves from the north through the southern hemisphere.

  5. Characterization of selected volatile organic compounds, polycyclic aromatic hydrocarbons and carbonyl compounds at a roadside monitoring station

    Science.gov (United States)

    Ho, K. F.; Lee, S. C.; Chiu, Gloria M. Y.

    Volatile organic compounds (VOCs), PAHs and carbonyl compounds are the major toxic components in Hong Kong. Emissions from motor vehicles have been one of the primary pollution sources in the metropolitan areas throughout Hong Kong for a long time. A 1-yr monitoring program for VOCs, PAHs and carbonyl compounds had been performed at a roadside urban station at Hong Kong Polytechnic University in order to determine the variations and correlations of each selected species (VOCs, PAHs and carbonyl compounds). This study is aimed to analyze toxic volatile organic compounds (benzene, toluene, ethylbenzene and xylene), two carbonyl compounds (formaldehyde, acetaldehyde), and selective polycyclic aromatic hydrocarbons. The monitoring program started from 16 April 1999 to 30 March 2000. Ambient VOC concentrations, many of which originate from the same sources as particulate PAHs and carbonyls compounds, show significant quantities of benzene, toluene and xylenes. Correlations and multivariate analysis of selected gaseous and particulate phase organic pollutants were performed. Source identification by principle component analysis and hierarchical cluster analysis allowed the identification of four sources (factors) for the roadside monitoring station. Factor 1 represents the effect of diesel vehicle exhaust. Factor 2 shows the contribution of aromatic compounds. Factor 3 explains photochemical products—formaldehyde and acetaldehyde. Factor 4 explains the effect of gasoline vehicle exhaust.

  6. Assessment of Radio-Frequency Radiation Exposure Level from Selected Mobile Base Stations (MBS) in Lokoja, Kogi State, Nigeria

    OpenAIRE

    Nwankwo, U. J. Victor; Jibiri, N. N.; Dada, S. S.; Onugba, A. A.; Ushie, P.

    2012-01-01

    The acquisition and use of mobile phone is tremendously increasing especially in developing countries, but not without a concern. The greater concern among the public is principally over the proximity of mobile base stations (MBS) to residential areas rather than the use of handsets. In this paper, we present an assessment of Radio-Frequency (RF) radiation exposure level measurements and analysis of radiation power density (in W/sq m) from mobile base stations relative to radial distance (in ...

  7. Monitoring of low level environmental gamma exposure by the centralized radiation monitoring system

    International Nuclear Information System (INIS)

    Katagiri, Hiroshi; Kobayashi, Hideo; Obata, Kazuichi; Kokubu, Morinobu; Itoh, Naoji

    1981-07-01

    In the Japan Atomic Energy Research Institute (JAERI), a centralized automatic radiation monitoring system developed 20 years ago has recently been improved to monitor low level gamma radiation more accurately in normal operation of the nuclear facilities and to detect abnormal radioactive releases more effectively. The present state of the system is described. This system puts together environmental monitoring data such as gamma exposure rate (20 points), radioactive concentration in the air (4 points) and in water (2 drains), and meteorological items (14 including wind directions, wind speeds, solar radiation and air temperatures at a observation tower of 40 m height). Environmental monitoring around the JAERI site is carried out effectively using the system. Data processing system consists of a central processing unit, a magnetic disk, a magnetic tape, a line printer and a console typewriter. The data at respective monitoring points are transmitted to the central monitoring room by wireless or telephone line. All data are printed out and field in magnetic disk and magnetic tape every 10 minutes. When the emergency levels are exceeded, however, the data are automatically output on a line printer every 2 minute. This system can distinguish very low gamma exposure due to gaseous effluents, about 1 mR/y, from the background. Even in monthly exposures, calculated values based on the data of release amount and meteorology are in good agreement with the measured ones. (author)

  8. Environmental monitoring of low-level radioactive materials

    International Nuclear Information System (INIS)

    Jester, W.A.; Yu, C.

    1985-01-01

    The authors discuss some of the current rationale behind the environmental monitoring of low-level radioactive materials are as follows: Committee 4 of the International commission on Radiological Protection (ICRP) defined three broad objectives for environmental monitoring: 1) assessment of the actual or potential exposure of humans to radioactive materials or radiation present in their environment or the estimation of the probable upper limits of such exposure; 2) scientific investigation, sometimes related to the assessment of exposures, sometimes to other objectives; 3) improved public relations. Various regulations have been written requiring environmental monitoring to ensure that the public is not being exposed to excessive amounts of radiation from natural sources or from human activities. An example of the monitoring of natural sources of radiation is a requirement of the Environmental Protection Agency's (EPA) National Interim Primary Drinking Water Regulations whereby U.S. water supply companies must have drinking water monitored at least once every four years for radionuclides, primarily the naturally occurring radium-226

  9. The use of cadmium telluride γ spectrometers in monitoring activity deposited in nuclear power stations

    International Nuclear Information System (INIS)

    Jones, L.T.

    1977-01-01

    The ability to inspect and test key components and when necessary repair or replace them is a significant factor in the safety case submitted before consent is given for construction of a nuclear reactor. A knowledge of the probable rate of deposition and isotopic composition of radioactive contamination in these areas is necessary and since it is not always practicable to take samples away to the laboratory for analysis, direct gamma ray spectroscopy in the contaminated environment is sometimes used. The experience of direct monitoring with a cadmium telluride spectrometer in two such reactor situations is reported. In the first situation, a remotely cooled intrinsic Germanium spectrometer was used in equivalent positions and spectra from both systems are presented. The relative merits of the two systems are discussed. In the second situation, measurements were made in an environment at 70 deg C in radiation levels of 10Rh -1 . An improvised cooling system was used to maintain the Cadmium Telluride at about 20 deg C and Pile-up Rejection was used to enable count rates of about 10 5 s -1 to be handled. It is noted that the usually quoted detector parameters, resolution and crystal volume, are not necessarily the most important in practical spectrometry of mixed isotopes. As with germanium detectors, the most useful parameter is probably the Peak-to-Compton ratio

  10. Long-term trends in airborne SO2 in an air quality monitoring station in Seoul, Korea, from 1987 to 2013.

    Science.gov (United States)

    Khan, Azmatullah; Kim, Ki-Hyun; Szulejko, Jan E; Brown, Richard J C; Jeon, Eui-Chan; Oh, Jong-Min; Shin, Yong Soon; Adelodun, Adedeji A

    2017-08-01

    Atmospheric concentration of sulfur dioxide (SO 2 ) was intermittently measured at an air quality monitoring (AQM) station in the Yong-san district of Seoul, Korea, between 1987 and 2013. The SO 2 level was compared with other important pollutants concurrently measured, including methane (CH 4 ), carbon monoxide (CO), nitric oxide (NO), nitrogen dioxide (NO 2 ), ozone (O 3 ), and particulate matter (PM 10 ). If split into three different periods (period 1, 1987-1988, period 2, 1999-2000, and period 3, 2004-2013), the respective mean [SO 2 ] values (6.57 ± 4.29, 6.30 ± 2.44, and 5.29 ± 0.63 ppb) showed a slight reduction across the entire study period. The concentrations of SO 2 are found to be strongly correlated with other pollutants such as CO (r = 0.614, p = 0.02), which tracked reductions in reported emissions due to tighter emissions standards enacted by the South Korean government. There was also a clear seasonal trend in the SO 2 level, especially in periods 2 and 3, reflecting the combined effects of domestic heating by coal briquettes and meteorological conditions. Although only a 16% concentration reduction was achieved during the 27-year study duration, this is significant if one considers rapid urbanization, an 83.2% increase in population, and rapid industrialization that took place during that period. Since 1970, a network of air quality monitoring (AQM) stations has been operated by the Korean Ministry of Environment (KMOE) for routine nationwide monitoring of air pollutant concentrations in urban/suburban areas. To date, the information obtained from these stations has provided a platform for analyzing long-term trends of major pollutant species. In this study, we examined the long-term trends of SO 2 levels and relevant environmental parameters monitored continuously in the Yong-san district of Seoul between 1987 and 2013. The data were analyzed over various time scales (i.e., monthly, seasonal, and annual intervals). The results obtained from

  11. SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION PROJECT

    Energy Technology Data Exchange (ETDEWEB)

    J. Robert Woolsey; Tom McGee; Carol Lutken; Elizabeth Stidham

    2006-06-01

    The Gulf of Mexico Hydrates Research Consortium (GOM-HRC) was established in 1999 to assemble leaders in gas hydrates research. The Consortium is administered by the Center for Marine Resources and Environmental Technology, CMRET, at the University of Mississippi. The primary objective of the group is to design and emplace a remote monitoring station or sea floor observatory (MS/SFO) on the sea floor in the northern Gulf of Mexico by the year 2007, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission, although unavoidably delayed by hurricanes and other disturbances, necessitates assembling a station that will monitor physical and chemical parameters of the marine environment, including sea water and sea-floor sediments, on a more-or-less continuous basis over an extended period of time. In 2005, biological monitoring, as a means of assessing environmental health was added to the mission of the MS/SFO. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in the arena of gas hydrates research. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. The observatory has now achieved a microbial dimension in addition to the geophysical and geochemical components it had already included. Initial components of the observatory, a probe that collects pore-fluid samples and another that records sea floor temperatures, were deployed in Mississippi Canyon 118 in May of 2005. Follow-up deployments, planned for fall 2005, had to be postponed due to the catastrophic effects of Hurricane Katrina (and later, Rita) on the Gulf Coast. Every effort was made to locate and retain the services of a suitable vessel and submersibles or Remotely Operated Vehicles (ROVs) following the storms and the loss of the contracted vessel

  12. Radioactivity monitoring by the official monitoring stations in North-Rhine Westphalia and the Juelich Nuclear Research Centre after the Chernobyl reactor accident

    International Nuclear Information System (INIS)

    1986-01-01

    This official report presents a governmental declaration of the prime minister of NRW, Mr. Rau, concerning the reactor accident at Chernobyl, and a joint declaration of ministers of NRW, concerning the impact of the accident on the Land NRW. These statements are completed by six official reports on radioactivity measurements carried out by the official monitoring stations of the Land and by the KFA Juelich. These reports inform about methods, scope, and results of the measuring campaigns accomplished by the Zentralstelle fuer Sicherheitstechnik (ZFS), the public materials testing office (MPA), the Chemisches Untersuchungsamt, the Landesamt fuer Wasser und Abfall, and the KFA Juelich. (DG) [de

  13. Monitoring of awareness level in dispensary patients with arterial hypertension.

    Science.gov (United States)

    Smiianov, Vladyslav; Witczak, Izabela; Smiianova, Olga; Rudenko, Lesia

    2017-01-01

    Results of monitoring of awareness level in dispensary patients with arterial hypertension (AH) are given in the article. The objective of the study was to investigate awareness level of dispensary patients with hypertension in Sumy as for the course of their disease, implementation of preventive measures, diagnosis and treatment, and to use the obtained information in the process of management of healthcare quality. The results of close-ended questionnaires were used in the capacity of materials. A total of 2019 patients were surveyed. Despite the high level of patients' awareness of AH course and possible complications, the survey showed insufficient level of their own responsibility for their health. The main reasons for poor adherence to doctor's recommendations are forgetfulness, lack of time, reluctance. Measures were developed to increase awareness level in patients with AH by means of strengthening awareness-raising activities and communications, as well as creation and implementation of effective targeted health-and-social programs.

  14. Natural radionuclides near a coal-fired power station. [/sup 210/Po and /sup 210/Pb levels in cattle livers

    Energy Technology Data Exchange (ETDEWEB)

    Smith-Briggs, J L; Crick, M J [National Radiological Protection Board, Harwell (UK)

    1982-11-01

    Previous measurements have shown enhanced levels of /sup 210/Po and /sup 210/Pb from fly ash deposited in the environment around old coal-fired power stations. Preliminary results are presented for levels of /sup 210/Po and /sup 210/Pb in liver samples from cattle which had grazed for two to three years in a field adjacent to a modern power station. No significant difference in the levels of these natural radionuclides was found compared to liver samples obtained from cattle in a control area.

  15. Monitoring PWR reactor vessel liquid level with SPNDs during LOCAs

    International Nuclear Information System (INIS)

    Adams, J.P.

    1982-01-01

    Data from in-core self-powered neutron detectors taken during two nuclear loss-of-coolant accident simulations have been correlated with core moderator density changes. The detector current attenuation has been calculated during blowdown and reflood phases of the simulation. Based on these data, it is concluded that these detectors could be used to monitor reactor vessel liquid level during loss-of-coolant accidents in pressurized water reactors

  16. A Two-Level Sound Classification Platform for Environmental Monitoring

    Directory of Open Access Journals (Sweden)

    Stelios A. Mitilineos

    2018-01-01

    Full Text Available STORM is an ongoing European research project that aims at developing an integrated platform for monitoring, protecting, and managing cultural heritage sites through technical and organizational innovation. Part of the scheduled preventive actions for the protection of cultural heritage is the development of wireless acoustic sensor networks (WASNs that will be used for assessing the impact of human-generated activities as well as for monitoring potentially hazardous environmental phenomena. Collected sound samples will be forwarded to a central server where they will be automatically classified in a hierarchical manner; anthropogenic and environmental activity will be monitored, and stakeholders will be alarmed in the case of potential malevolent behavior or natural phenomena like excess rainfall, fire, gale, high tides, and waves. Herein, we present an integrated platform that includes sound sample denoising using wavelets, feature extraction from sound samples, Gaussian mixture modeling of these features, and a powerful two-layer neural network for automatic classification. We contribute to previous work by extending the proposed classification platform to perform low-level classification too, i.e., classify sounds to further subclasses that include airplane, car, and pistol sounds for the anthropogenic sound class; bird, dog, and snake sounds for the biophysical sound class; and fire, waterfall, and gale for the geophysical sound class. Classification results exhibit outstanding classification accuracy in both high-level and low-level classification thus demonstrating the feasibility of the proposed approach.

  17. Assessment of environmental gamma radiation levels in the environs of Narora Atomic Power Station (NAPS)

    International Nuclear Information System (INIS)

    Shetty, P.G.; Takale, R.A.; Swarnkar, M.; Sahu, S.K.; Pandit, G.G.; Puranik, V.D.

    2011-01-01

    As a part of the assessment of the environmental impact of the Indian nuclear power programme, radiation surveys are being carried out on continuous basis in the environs of all the nuclear facilities in India using Thermoluminescent Dosimeters. This paper discusses the environmental gamma radiation levels based on the analysis of data generated for year 1989-2009 at twenty-eight locations currently being monitored in and around the environs of NAPS using passive dosimeter. Of these, six are within the exclusion zone (1.6 km) while the remaining twenty two locations are spread over an aerial distance of twenty six km from reactor stack. The annual background gamma levels for NAPS site beyond 1.6 km exclusion zone based on twenty-two monitoring locations are evaluated and seen to be 1.20 ± 0.15 mGy/a. This is comparable with earlier reported pre-operational value 1.24 ± 0.26 mGy/a. From this it can be said that the reactor operations have not contributed to any increase in the gamma radiation levels in the environs of the NAPS region. (author)

  18. Environmental monitoring of low-level radioactive waste disposal facility

    International Nuclear Information System (INIS)

    Shum, E.Y.; Starmer, R.J.; Young, M.H.

    1989-12-01

    This branch technical position (BTP) paper on the environmental monitoring program for a low-level radioactive waste disposal facility provides general guidance on what is required by Section 61.53 of Title 10 of the Code of Federal Regulations (10 CFR) of applicants submitting a license application for such a facility. In general, the environmental monitoring program consists of three phases: preoperational, operational, and postoperational. Each phase of the monitoring program should be designed to fulfill the specific objectives defined in the BTP paper. During the preoperational phase, the objectives of the program are to provide site characterization information, to demonstrate site suitability and acceptability, to obtain background or baseline information, and to provide a record for public information. During the operational phase, the emphasis on measurement shifts. Monitoring data are obtained to provide early warning of releases and to document compliance with regulations, the dose limits of 10 CFR Part 61, or applicable standards of the US Environmental Protection Agency. Data are also used to update important pathway parameters to improve predictions of site performance and to provide a record of performance for public information. The postoperational environmental monitoring program emphasizes measurements to demonstrate compliance with the site-closure requirements and continued compliance with the performance objective in regard to the release of radionuclides to the environment. The data are used to support evaluation of long-term effects on the general public and for public information. Guidance is also provided in the BTP paper on the choice of which constituents to measure, setting action levels, relating measurements to appropriate actions in a corrective action plan, and quality assurance

  19. Condition monitoring and signature analysis techniques as applied to Madras Atomic Power Station (MAPS) [Paper No.: VIA - 1

    International Nuclear Information System (INIS)

    Rangarajan, V.; Suryanarayana, L.

    1981-01-01

    The technique of vibration signature analysis for identifying the machine troubles in their early stages is explained. The advantage is that a timely corrective action can be planned to avoid breakdowns and unplanned shutdowns. At the Madras Atomic Power Station (MAPS), this technique is applied to regularly monitor vibrations of equipment and thus is serving as a tool for doing corrective maintenance of equipment. Case studies of application of this technique to main boiler feed pumps, moderation pump motors, centrifugal chiller, ventilation system fans, thermal shield ventilation fans, filtered water pumps, emergency process sea water pumps, and antifriction bearings of MAPS are presented. Condition monitoring during commissioning and subsequent operation could indicate defects. Corrective actions which were taken are described. (M.G.B.)

  20. Wind profiler observations of a monsoon low-level jet over a tropical Indian station

    Directory of Open Access Journals (Sweden)

    M. C. R. Kalapureddy

    2007-11-01

    Full Text Available Three-year high-resolution wind observations of the wind profiler have been utilized to characterize the diurnal and seasonal features of the monsoon Low-Level Jet (LLJ over a tropical station, Gadanki (13.5° N, 79.2° E, with a focus on the diurnal variability of low-level winds. The Boreal summer monsoon winds show a conspicuously strong westerly LLJ with average wind speed exceeding 20 m s−1. The L-band wind profiler measurements have shown an advantage of better height and time resolutions over the conventional radiosonde method for diurnal wind measurements. An interesting diurnal oscillation of LLJ core has been observed. It is varying in the height range of 1.8±0.6 km with the maximum and minimum intensity noticed during the early morning and afternoon hours, respectively. The jet core (wind maxima height is observed to coincide with the inversion height. Strong wind shears are normally located beneath the LLJ core. The sole wind profiler observations are capable of identifying the monsoon phases, such as onset, break and active spells, etc. The mutual influence between the LLJ and the boundary layer has been discussed. One notices that the observed LLJ diurnal structures depend on the local convective activity, wind shears and turbulence activity associated with boundary layer winds. The day-to-day change in the LLJ structure depends on the latitudinal position of the LLJ core.

  1. Microprocessor-assisted calibration for a remote working level monitor

    International Nuclear Information System (INIS)

    McDowell, W.P.; Keefe, D.J.; Groer, P.G.; Witek, R.T.

    1977-01-01

    A method is described for calibrating a Remote Working Level Monitor, an instrument which measures Working Level and Rn-daughter concentrations in the atmosphere. The method makes use of a microprocessor to calculate beta efficiencies for RaB and RaC from the counts accumulated in the RaA, Ra(B + C) and RaC' channels of the instrument. Both the alpha spectroscopic and total-alpha methods are used to determine the Rn-daughter concentrations. These methods require the processor to solve systems of linear equations with several unknowns. No assumptions about Rn-daughter equilibrium are made

  2. Microprocessor-assisted calibration for a remote working level monitor

    International Nuclear Information System (INIS)

    McDowell, W.P.; Keefe, D.J.; Groer, P.G.; Witek, R.T.

    1976-01-01

    A method is described for calibrating a Remote Working Level Monitor, an instrument which measures Working Level and Rn-daughter concentrations in the atmosphere. The method makes use of a microprocessor to calculate beta efficiencies for RaB and RaC from the counts accumulated in the RaA, Ra(B + C) and RaC' channels of the instrument. Both the alpha spectroscopic and total-alpha methods are used to determine the Rn-daughter concentrations. These methods require the processor to solve systems of linear equations with several unknowns. No assumptions about Rn-daughter equilibrium are made

  3. The capacity of radar, crowdsourced personal weather stations and commercial microwave links to monitor small scale urban rainfall

    Science.gov (United States)

    Uijlenhoet, R.; de Vos, L. W.; Leijnse, H.; Overeem, A.; Raupach, T. H.; Berne, A.

    2017-12-01

    For the purpose of urban rainfall monitoring high resolution rainfall measurements are desirable. Typically C-band radar can provide rainfall intensities at km grid cells every 5 minutes. Opportunistic sensing with commercial microwave links yields rainfall intensities over link paths within cities. Additionally, recent developments have made it possible to obtain large amounts of urban in situ measurements from weather amateurs in near real-time. With a known high resolution simulated rainfall event the accuracy of these three techniques is evaluated, taking into account their respective existing layouts and sampling methods. Under ideal measurement conditions, the weather station networks proves to be most promising. For accurate estimation with radar, an appropriate choice for Z-R relationship is vital. Though both the microwave links and the weather station networks are quite dense, both techniques will underestimate rainfall if not at least one link path / station captures the high intensity rainfall peak. The accuracy of each technique improves when considering rainfall at larger scales, especially by increasing time intervals, with the steepest improvements found in microwave links.

  4. Finding candidate locations for aerosol pollution monitoring at street level using a data-driven methodology

    Science.gov (United States)

    Moosavi, V.; Aschwanden, G.; Velasco, E.

    2015-09-01

    Finding the number and best locations of fixed air quality monitoring stations at street level is challenging because of the complexity of the urban environment and the large number of factors affecting the pollutants concentration. Data sets of such urban parameters as land use, building morphology and street geometry in high-resolution grid cells in combination with direct measurements of airborne pollutants at high frequency (1-10 s) along a reasonable number of streets can be used to interpolate concentration of pollutants in a whole gridded domain and determine the optimum number of monitoring sites and best locations for a network of fixed monitors at ground level. In this context, a data-driven modeling methodology is developed based on the application of Self-Organizing Map (SOM) to approximate the nonlinear relations between urban parameters (80 in this work) and aerosol pollution data, such as mass and number concentrations measured along streets of a commercial/residential neighborhood of Singapore. Cross-validations between measured and predicted aerosol concentrations based on the urban parameters at each individual grid cell showed satisfying results. This proof of concept study showed that the selected urban parameters proved to be an appropriate indirect measure of aerosol concentrations within the studied area. The potential locations for fixed air quality monitors are identified through clustering of areas (i.e., group of cells) with similar urban patterns. The typological center of each cluster corresponds to the most representative cell for all other cells in the cluster. In the studied neighborhood four different clusters were identified and for each cluster potential sites for air quality monitoring at ground level are identified.

  5. Application of Terrestrial Ecosystem Monitoring under the CAFF Circumpolar Biodiversity Monitoring Program: Designing and Implementing Terrestrial Monitoring to Establish the Canadian High Arctic Research Station as a Flagship Arctic Environmental Monitoring Site

    Science.gov (United States)

    McLennan, D.; Kehler, D.

    2016-12-01

    The Canadian High Arctic Research Station (CHARS) is scheduled for completion in July 2017 and is the northern science component of Polar Knowledge Canada (POLAR). A mandated goal for POLAR is to establish the adjacent Experimental and Reference Area (ERA) as an Arctic Flagship monitoring site that will track change in Arctic terrestrial, freshwater and marine ecosystems. Situated in the community of Cambridge Bay, CHARS provides the opportunity to draw on the Indigenous Knowledge of local residents to help design and conduct the monitoring, and to operate 12 months a year. Monitoring at CHARS will be linked to networks nationally and internationally, and is being designed so that change in key indicators can be understood in terms of drivers and processes, modeled and scaled up regionally, and used to predict important changes in critical indicators. As a partner in the Circumpolar Biodiversity Monitoring Program (CBMP), the monitoring design for terrestrial ecosystems follows approaches outlined by the CBMP Terrestrial Expert Monitoring Group, who have listed key monitoring questions and identified a list of important Focal Ecosystem Components (FECs). To link drivers to FECs we are proposing a multi-scaled approach: 1) an Intensive Monitoring Area to establish replicated monitoring plots that track change in snow depth and condition, active layer depth, soil temperature, soil moisture, and soil solution chemistry that are spatially and temporally linked to changes in microbiological activity, CO2/CH4 net ecosystem flux, vegetation relative frequency, species composition, growth and foliar nutrient concentration, arthropod abundance, lemming abundance and health, and shorebird/songbird abundance and productivity. 2) These intensive observations are supported by watershed scale measures that will monitor, during the growing season, lemming winter nest abundance, songbird, shorebird and waterfowl staging and nesting, and other observations; in the winter we will

  6. EPA Office of Water (OW): STORET Water Quality Monitoring Stations NHDPlus Indexed Dataset

    Data.gov (United States)

    U.S. Environmental Protection Agency — Storage and Retrieval for Water Quality Data (STORET and the Water Quality Exchange, WQX) defines the methods and the data systems by which EPA compiles monitoring...

  7. Detection of Atmospheric Explosions at IMS Monitoring Stations using Infrasound Techniques

    National Research Council Canada - National Science Library

    Christie, Douglas R; Kennett, Brian L; Tarlowski, Chris

    2006-01-01

    Work is continuing on the development of infrasound techniques that can be used to improve detection, location and discrimination capability for atmospheric nuclear explosions at International Monitoring System (IMS...

  8. EPA Office of Water (OW): STORET Water Quality Monitoring Stations Source Dataset

    Data.gov (United States)

    U.S. Environmental Protection Agency — Storage and Retrieval for Water Quality Data (STORET and the Water Quality Exchange, WQX) defines the methods and the data systems by which EPA compiles monitoring...

  9. Long open-path TDL based system for monitoring background concentration for deployment at Jungfraujoch High Altitude Research Station- Switzerland

    Science.gov (United States)

    Simeonov, Valentin; van den Bergh, Hubert; Parlange, Marc

    2010-05-01

    A new, long open-path instrument for monitoring of path-averaged methane and water vapor concentrations will be presented. The instrument is built on the monostatic scheme (transceiver - distant retroreflector). A VCSEL tunable diode laser (TDL) with a central wavelength of 1654 nm is used as a light source. A specially designed, single-cell, hollow-cube retroreflector with 150 mm aperture will be installed at 1200 m from the transceiver in the final deployment at Jungfraujjoch and 100 mm retroreflectors will be used in the other applications. The receiver is built around a 20 cm Newtonian telescope. To avoid distortions in the shape of a methane line, caused by atmospheric turbulences, the line is scanned within 1 µs. Fast InGaAs photodiodes and 200 MHz are used to achieve this scanning rate. The expected concentration resolution for the above mentioned path lengths is of the order of 2 ppb. The instrument is developed at the Swiss Federal Institute of Technology - Lausanne (EPFL) Switzerland and will be used within the GAW+ CH program for long-term monitoring of background methane concentration in the Swiss Alps. After completing the initial tests at EPFL the instrument will be installed in 2012 at the High Altitude Research Station Jungfraujoch (HARSJ) located at 3580 m ASL. The HARSJ is one of the 24 global GAW stations and carries on continuous observations of a number of trace gasses, including methane. One of the goals of the project is to compare path-averaged to ongoing point measurements of methane in order to identify possible influence of the station. Future deployments of a copy of the instrument include the Colombian part of Amazonia and Siberian wetlands.

  10. Predictive monitoring and diagnosis of periodic air pollution in a subway station.

    Science.gov (United States)

    Kim, YongSu; Kim, MinJung; Lim, JungJin; Kim, Jeong Tai; Yoo, ChangKyoo

    2010-11-15

    The purpose of this study was to develop a predictive monitoring and diagnosis system for the air pollutants in a subway system using a lifting technique with a multiway principal component analysis (MPCA) which monitors the periodic patterns of the air pollutants and diagnoses the sources of the contamination. The basic purpose of this lifting technique was to capture the multivariate and periodic characteristics of all of the indoor air samples collected during each day. These characteristics could then be used to improve the handling of strong periodic fluctuations in the air quality environment in subway systems and will allow important changes in the indoor air quality to be quickly detected. The predictive monitoring approach was applied to a real indoor air quality dataset collected by telemonitoring systems (TMS) that indicated some periodic variations in the air pollutants and multivariate relationships between the measured variables. Two monitoring models--global and seasonal--were developed to study climate change in Korea. The proposed predictive monitoring method using the lifted model resulted in fewer false alarms and missed faults due to non-stationary behavior than that were experienced with the conventional methods. This method could be used to identify the contributions of various pollution sources. Copyright © 2010 Elsevier B.V. All rights reserved.

  11. Forecasting Method for Urban Rail Transit Ridership at Station Level Using Back Propagation Neural Network

    Directory of Open Access Journals (Sweden)

    Junfang Li

    2016-01-01

    Full Text Available Direct forecasting method for Urban Rail Transit (URT ridership at the station level is not able to reflect nonlinear relationship between ridership and its predictors. Also, population is inappropriately expressed in this method since it is not uniformly distributed by area. In this paper, a new variable, population per distance band, is considered and a back propagation neural network (BPNN model which can reflect nonlinear relationship between ridership and its predictors is proposed to forecast ridership. Key predictors are obtained through partial correlation analysis. The performance of the proposed model is compared with three other benchmark models, which are linear model with population per distance band, BPNN model with total population, and linear model with total population, using four measures of effectiveness (MOEs, maximum relative error (MRE, smallest relative error (SRE, average relative error (ARE, and mean square root of relative error (MSRRE. Also, another model for contribution rate of population per distance band to ridership is formulated based on the BPNN model with nonpopulation variables fixed. Case studies with Japanese data show that BPNN model with population per distance band outperforms other three models and the contribution rate of population within special distance band to ridership calculated through the contribution rate model is 70%~92.9% close to actual statistical value. The result confirms the effectiveness of models proposed in this paper.

  12. Preliminary Assessment of Radiofrequency Radiation Exposure Level, From Mobile Base Stations in Ajaokuta and Environs, Kogi State, Nigeria

    International Nuclear Information System (INIS)

    Ushie, P. O.; Nwankwo, U.J.V.; Osahun, O. D.; Ayinmode, B.

    2013-01-01

    We present the result of a preliminary assessment of radio-frequency radiation exposure from selected mobile base stations in Ajaokuta environs using radio frequency (RF) meter (electromoge meter). The Power density of RF radiation within a radial distance of 125m was measured. Although values fluctuated due to the influence of unavoidable factors suspected to be interferences from other electromagnetic sources around reference base stations, we show from analysis that radiation exposure level is far below the standard limit (10W/cm 2 or 10 7 μW/m 2 ) set by the International Commission on Non-ionizing Radiation Protection (ICNIRP) regulatory agencies. The assessment was done in about ten (10) base stations in Ajaokuta, Kogi state. The position and elevation of the base stations were noted using a global positioning system (GPS) to ascertain the position of such stations on the world map. It was discovered that the limit of exposure to radio frequency radiation set by International Commission on Non-ionizing, Radiation Protection (ICNIRP) of 900MHz band expressed in the same unit as 10W/cm 2 or 10 7 μW/m 2 was not exceeded, the values were also influenced by some inevitable factors. Positions of most of the stations are sited close to homes.

  13. A microcontroller-based data-acquisition system for meteorological station monitoring

    International Nuclear Information System (INIS)

    Rosiek, S.; Batlles, F.J.

    2008-01-01

    This paper presents a study of feasibility of different existing methodologies linked to field's data acquisition from remote meteorological stations. The data transmission serves to collect field's meteorological information, such as temperature, humidity and radiation. In our study the experimental data is registered in a weather station located about 100 km from University of Almeria. Various existing techniques are studied, especially Radio, GSM (global system of mobile communication) and GPRS (general packet radio service). In the result of these studies has been designed a system of field's data acquisition (herein referred as Meteologger) which we are going to present in this paper. The system is based on an ATmega 16 microcontroller, which scans 8 sensors together at any programmable intervals. This paper presents the study of the mentioned project, application and some main characteristics of the prototype system and its program. We attempt to implement the system, and subsequently present the performance of tests regarding the mentioned system. To verify its functioning some comparison of this measurement system with two others commercial data-acquisition system (Campbell and Hobo H8) has been carried out

  14. A microcontroller-based data-acquisition system for meteorological station monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Rosiek, S.; Batlles, F.J. [Dpto. Fisica Aplicada, Universidad de Almeria, 04120 Almeria (Spain)

    2008-12-15

    This paper presents a study of feasibility of different existing methodologies linked to field's data acquisition from remote meteorological stations. The data transmission serves to collect field's meteorological information, such as temperature, humidity and radiation. In our study the experimental data is registered in a weather station located about 100 km from the University of Almeria. Various existing techniques are studied, especially Radio, GSM (global system of mobile communication) and GPRS (general packet radio service). In the result of these studies has been designed a system of field's data acquisition (herein referred as Meteologger) which we are going to present in this paper. The system is based on an ATmega 16 microcontroller, which scans 8 sensors together at any programmable intervals. This paper presents the study of the mentioned project, application and some main characteristics of the prototype system and its program. We attempt to implement the system, and subsequently present the performance of tests regarding the mentioned system. To verify its functioning some comparison of this measurement system with two others commercial data-acquisition system (Campbell and Hobo H8) has been carried out. (author)

  15. Evaluation of available analytical techniques for monitoring the quality of space station potable water

    Science.gov (United States)

    Geer, Richard D.

    1989-01-01

    To assure the quality of potable water (PW) on the Space Station (SS) a number of chemical and physical tests must be conducted routinely. After reviewing the requirements for potable water, both direct and indirect analytical methods are evaluated that could make the required tests and improvements compatible with the Space Station operation. A variety of suggestions are made to improve the analytical techniques for SS operation. The most important recommendations are: (1) the silver/silver chloride electrode (SB) method of removing I sub 2/I (-) biocide from the water, since it may interfere with analytical procedures for PW and also its end uses; (2) the orbital reactor (OR) method of carrying out chemistry and electrochemistry in microgravity by using a disk shaped reactor on an orbital table to impart artificial G force to the contents, allowing solution mixing and separation of gases and liquids; and (3) a simple ultra low volume highly sensitive electrochemical/conductivity detector for use with a capillary zone electrophoresis apparatus. It is also recommended, since several different conductivity and resistance measurements are made during the analysis of PW, that the bipolar pulse measuring circuit be used in all these applications for maximum compatibility and redundancy of equipment.

  16. Performance Evaluation of the Operational Air Quality Monitor for Water Testing Aboard the International Space Station

    Science.gov (United States)

    Wallace, William T.; Limero, Thomas F.; Gazda, Daniel B.; Minton, John M.; Macatangay, Ariel V.; Dwivedi, Prabha; Fernandez, Facundo M.

    2014-01-01

    Real-time environmental monitoring on ISS is necessary to provide data in a timely fashion and to help ensure astronaut health. Current real-time water TOC monitoring provides high-quality trending information, but compound-specific data is needed. The combination of ETV with the AQM showed that compounds of interest could be liberated from water and analyzed in the same manner as air sampling. Calibration of the AQM using water samples allowed for the quantitative analysis of ISS archival samples. Some calibration issues remain, but the excellent accuracy of DMSD indicates that ETV holds promise for as a sample introduction method for water analysis in spaceflight.

  17. Hydrogeological monitoring (0-15 km of the Chernobyl' station affected zone)

    International Nuclear Information System (INIS)

    Sitnikov, A.B.; Dzheko, S.P.

    1992-01-01

    Hydrogeological monitoring (HM) is aimed at finding out the regularities of formation of subsurface water, as well as unfavorable phenomena and parameters used for forecasts. To the main objects of HM belong: surface storm run-off; soil moisture of the aeration zone; underground water; water-bearing horizons in Buchak and Senomazh depositions. Criteria for grounding the system of monitoring and control are presented. The elements of the system for tracking local HM in 10-15 km zone are given. Potential centres of unfavorable phenomena, as well as the objects to be protected are noted. 3 figs

  18. Support of Gulf of Mexico Hydrate Research Consortium: Activities to Support Establishment of a Sea Floor Monitoring Station Project

    Energy Technology Data Exchange (ETDEWEB)

    J. Robert Woolsey; Thomas M. McGee; Carol Blanton Lutken; Elizabeth Stidham

    2007-03-31

    The Gulf of Mexico Hydrates Research Consortium (GOM-HRC) was established in 1999 to assemble leaders in gas hydrates research. The Consortium is administered by the Center for Marine Resources and Environmental Technology, CMRET, at the University of Mississippi. The primary objective of the group is to design and emplace a remote monitoring station or sea floor observatory (MS/SFO) on the sea floor in the northern Gulf of Mexico by the year 2007, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission, although unavoidably delayed by hurricanes and other disturbances, necessitates assembling a station that will monitor physical and chemical parameters of the marine environment, including sea water and sea-floor sediments, on a more-or-less continuous basis over an extended period of time. In 2005, biological monitoring, as a means of assessing environmental health, was added to the mission of the MS/SFO. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in the arena of gas hydrates research. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. The observatory has now achieved a microbial dimension in addition to the geophysical, geological, and geochemical components it had already included. Initial components of the observatory, a probe that collects pore-fluid samples and another that records sea floor temperatures, were deployed in Mississippi Canyon 118 (MC118) in May of 2005. Follow-up deployments, planned for fall 2005, had to be postponed due to the catastrophic effects of Hurricane Katrina (and later, Rita) on the Gulf Coast. Station/observatory completion, anticipated for 2007, will likely be delayed by at least one year. These delays caused scheduling and deployments difficulties but many

  19. Low-level radioactive gas monitor for natural gas operations

    International Nuclear Information System (INIS)

    Armstrong, F.E.

    1969-11-01

    A portable radioactivity detection system for monitoring the tritium content of natural gas under field conditions has been developed. The sensing device employed is a complex proportional counting assembly operated without the use of massive shielding previously employed with such low-level radiation detectors. The practical limit of detection for the system is a tritium content of 10 -9 microcurie per cc of natural gas. All components of the system are packaged in three waterproof cases weighing slightly less than 30 kg each. Power requirement is 500 watts of 120 volt, 60 Hz current. Operation is fully automatic with a printed record produced at predetermined time intervals

  20. Formal specification and animation of a water level monitoring system

    International Nuclear Information System (INIS)

    Jackson, P.S.; Stokes, P.A.

    1993-03-01

    This report describes the Vienna Development Method (VDM), which is a formal method for software specification and development. VDM evolved out of attempts to use mathematics in programming language specifications in order to avoid ambiguities in specifications written in natural language. This report also describes the use of VDM for a real-time application, where it is used to formally specify the requirements of a water level monitoring system. The procedures and techniques used to produce an executable form (animation) of the specification are covered. (Author)

  1. South Baltic representative coastal field surveys, including monitoring at the Coastal Research Station in Lubiatowo, Poland

    Science.gov (United States)

    Ostrowski, Rafał; Schönhofer, Jan; Szmytkiewicz, Piotr

    2016-10-01

    The paper contains a brief description of selected investigations carried out in the south Baltic coastal zone, with the particular focus on the history and recent activities conducted at the Coastal Research Station in Lubiatowo (CRS Lubiatowo), Poland. These activities comprise field investigations of nearshore hydrodynamic, lithodynamic, and morphodynamic processes. The study area is a sandy multi-bar shore with a mild slope, much exposed to the impact of waves approaching from NW-NE sector. The shore has a dissipative character which means that the wave energy is subject to gradual dissipation in the nearshore zone and only a small part of this energy is reflected by the shore. Due to the big wind fetch in N-NNE direction, the location of CRS Lubiatowo is favourable to registration of the maximum values of parameters of hydrodynamic and morphodynamic processes which occur in the Baltic during extreme storms.

  2. Monitoring and conservation of power station components; Ueberwachung der Konservierung von Kraftwerkskomponenten

    Energy Technology Data Exchange (ETDEWEB)

    Weber, R.; Mohr, G. [Allianz-Zentrum fuer Technik GmbH (AZT), Ismaning (Germany)

    2000-07-01

    There are very many reasons why power station components should be treated and conserved as high-value industrial goods. Various considerations, such as transport type and distance and storage duration and location, then become important. This article deals with the special problems and considers the corresponding fundamentals on the basis of a specific example. Emphasis is given to the effects of atmosphere and climate but also to various corrosive mechanisms and to packing and conservation. (orig.) [German] Als hochwertige Industriegueter muessen Kraftwerkskomponenten aus unterschiedlichsten Gruenden konserviert werden. Dabei sind verschiedenerlei Gesichtspunkte massgeblich, wie Transportart und -weg sowie Lagerungsdauer und -ort. Hier wird anhand eines konkreten Beispiels ueber diese spezielle Problematik und die entsprechenden Grundlagen berichtet. Im Vordergrund stehen Einfluesse von Atmosphaere und Klima, aber auch diverse Korrosionsmechanismen sowie Verpackung und Konservierung. (orig.)

  3. Operation and maintenance of thermal power stations best practices and health monitoring

    CERN Document Server

    Chanda, Pradip

    2016-01-01

    This book illustrates operation and maintenance practices/guidelines for economic generation and managing health of a thermal power generator beyond its regulatory life. The book provides knowledge for professionals managing power station operations, through its unique approach to chemical analysis of water, steam, oil etc. to identify malfunctioning/defects in equipment/systems much before the physical manifestation of the problem. The book also contains a detailed procedure for conducting performance evaluation tests on different equipment, and for analyzing test results for predicting maintenance requirements, which has lent a new dimension to power systems operation and maintenance practices. A number of real life case studies also enrich the book. This book will prove particularly useful to power systems operations professionals in the developing economies, and also to researchers and students involved in studying power systems operations and control. .

  4. Monitoring the risk of loss of heat sink during plant shutdowns at Bruce Generating Station 'A'

    International Nuclear Information System (INIS)

    Krishnan, K.S.; Mancuso, F.; Vecchiarelli, D.

    1996-01-01

    A relatively simple loss of shutdown heat sink fault tree model has been developed and used during unit outages at Bruce Nuclear Generation Station 'A' to assess, from a risk and reliability perspective, alternative heat sink strategies and to aid in decisions on allowable outage configurations. The model is adjusted to reflect the various unit configurations planned during a specific outage, and identifies events and event combinations leading to loss of fuel cooling. The calculated failure frequencies are compared to the limits consistent with corporate and international public safety goals. The importance measures generated by the interrogation of the fault tree model for each outage configuration are also used to reschedule configurations with high fuel damage frequency later into the outage and to control the configurations with relatively high probability of fuel damage to short intervals at the most appropriate time into the outage. (author)

  5. Relationship Between Carbon Dioxide Levels and Reported Congestion and Headaches on the International Space Station

    Science.gov (United States)

    Cole, Robert; Wear, Mary; Young, Millennia; Cobel, Christopher; Mason, Sara

    2017-01-01

    Congestion is commonly reported during spaceflight, and most crewmembers have reported using medications for congestion during International Space Station (ISS) missions. Although congestion has been attributed to fluid shifts during spaceflight, fluid status reaches equilibrium during the first week after launch while congestion continues to be reported throughout long duration missions. Congestion complaints have anecdotally been reported in relation to ISS CO2 levels; this evaluation was undertaken to determine whether or not an association exists. METHODS: Reported headaches, congestion symptoms, and CO2 levels were obtained for ISS expeditions 2-31, and time-weighted means and single-point maxima were determined for 24-hour (24hr) and 7-day (7d) periods prior to each weekly private medical conference. Multiple imputation addressed missing data, and logistic regression modeled the relationship between probability of reported event of congestion or headache and CO2 levels, adjusted for possible confounding covariates. The first seven days of spaceflight were not included to control for fluid shifts. Data were evaluated to determine the concentration of CO2 required to maintain the risk of congestion below 1% to allow for direct comparison with a previously published evaluation of CO2 concentrations and headache. RESULTS: This study confirmed a previously identified significant association between CO2 and headache and also found a significant association between CO2 and congestion. For each 1-mm Hg increase in CO2, the odds of a crew member reporting congestion doubled. The average 7-day CO2 would need to be maintained below 1.5 mmHg to keep the risk of congestion below 1%. The predicted probability curves of ISS headache and congestion curves appear parallel when plotted against ppCO2 levels with congestion occurring at approximately 1mmHg lower than a headache would be reported. DISCUSSION: While the cause of congestion is multifactorial, this study showed

  6. Monitoring of radionuclides in the environs of the Finnish nuclear power stations in 1988

    International Nuclear Information System (INIS)

    Klemola, S.; Ilus, E.; Sjoeblom, K.L.; Arvela, H.; Blomqvist, L.

    1991-03-01

    Monitoring of radionuclides around Finnish nuclear power plants continued in 1988 with the regular programmes. About 1000 samples were analysed from both terrestrial and aquatic environments.The dominant artificial radioactive substances in the vicinity of power plants were still the fallout nuclides from the Chernobyl accident, but the concentrations in all the objects monitored are lower than in the previous year. Trace amounts of activation products originating from the airborne releases of local power plants were detected in some air and deposition samples. Discharged nuclides were more abundant in the aquatic environment, especially in samples of indicator organisms. However, their contribution to the radiation doses received by the the public was very small. (orig.)

  7. Monitoring the levels of important nutrients in the food supply.

    Science.gov (United States)

    Neal, B; Sacks, G; Swinburn, B; Vandevijvere, S; Dunford, E; Snowdon, W; Webster, J; Barquera, S; Friel, S; Hawkes, C; Kelly, B; Kumanyika, S; L'Abbé, M; Lee, A; Lobstein, T; Ma, J; Macmullan, J; Mohan, S; Monteiro, C; Rayner, M; Sanders, D; Walker, C

    2013-10-01

    A food supply that delivers energy-dense products with high levels of salt, saturated fats and trans fats, in large portion sizes, is a major cause of non-communicable diseases (NCDs). The highly processed foods produced by large food corporations are primary drivers of increases in consumption of these adverse nutrients. The objective of this paper is to present an approach to monitoring food composition that can both document the extent of the problem and underpin novel actions to address it. The monitoring approach seeks to systematically collect information on high-level contextual factors influencing food composition and assess the energy density, salt, saturated fat, trans fats and portion sizes of highly processed foods for sale in retail outlets (with a focus on supermarkets and quick-service restaurants). Regular surveys of food composition are proposed across geographies and over time using a pragmatic, standardized methodology. Surveys have already been undertaken in several high- and middle-income countries, and the trends have been valuable in informing policy approaches. The purpose of collecting data is not to exhaustively document the composition of all foods in the food supply in each country, but rather to provide information to support governments, industry and communities to develop and enact strategies to curb food-related NCDs. © 2013 The Authors. Obesity Reviews published by John Wiley & Sons Ltd on behalf of the International Association for the Study of Obesity.

  8. European experience on air and water pollution control: monitoring network and warning station

    Energy Technology Data Exchange (ETDEWEB)

    Aflalo, Sergio S. [Groupe Environnement S.A., Poissy (France)

    1993-12-31

    After a review of the energy consumption and pollutants emitted in the European Community, especially those concerning the `green house effect`, the author proceeded a summary of the actual legislation and Europeans directives, and also, the Best Available Technology for reducing air pollution is discussed. Original Air Quality monitoring networks performed by Environnement SA are described including measurements obtained around Paris and other areas of France. 7 refs., 11 figs.

  9. European experience on air and water pollution control: monitoring network and warning station

    Energy Technology Data Exchange (ETDEWEB)

    Aflalo, Sergio S [Groupe Environnement S.A., Poissy (France)

    1994-12-31

    After a review of the energy consumption and pollutants emitted in the European Community, especially those concerning the `green house effect`, the author proceeded a summary of the actual legislation and Europeans directives, and also, the Best Available Technology for reducing air pollution is discussed. Original Air Quality monitoring networks performed by Environnement SA are described including measurements obtained around Paris and other areas of France. 7 refs., 11 figs.

  10. Limnological Monitoring on the Upper Mississippi River System, 1993-1996: Long Term Resource Monitoring Program Havana Field Station

    National Research Council Canada - National Science Library

    Soballe, David

    2002-01-01

    .... The flood in spring 1995 receded sooner than in 1993. However, the 137 m (450.66 feet) peak on May 31, 1995, was the third highest river elevation recorded at Havana, Illinois. Low dissolved oxygen levels in the main channel were also notable in 1993-1996 with concentrations at or below 5 mg/L observed each year.

  11. National Coral Reef Monitoring Program: Benthic Complexity and Urchin Abundance of Climate Stations at Wake Island from 2014-03-16 to 2014-03-20 (NCEI Accession 0159160)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The benthic complexity and urchin abundance monitoring effort provides baselines for tracking these variables at NCRMP climate stations. Climate stations are 3-4...

  12. SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION PROJECT

    Energy Technology Data Exchange (ETDEWEB)

    Paul Higley; J. Robert Woolsey; Ralph Goodman; Vernon Asper; Boris Mizaikoff; Angela Davis

    2005-08-01

    A Consortium, designed to assemble leaders in gas hydrates research, has been established at the University of Mississippi's Center for Marine Resources and Environmental Technology, CMRET. The primary objective of the group is to design and emplace a remote monitoring station on the sea floor in the northern Gulf of Mexico by the year 2005, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission necessitates assembling a station that will monitor physical and chemical parameters of the sea water and sea floor sediments on a more-or-less continuous basis over an extended period of time. Development of the station allows for the possibility of expanding its capabilities to include biological monitoring, as a means of assessing environmental health. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in this relatively new research arena. Complementary expertise, both scientific and technical, has been assembled to innovate research methods and construct necessary instrumentation. A year into the life of this cooperative agreement, we note the following achievements: (1) Progress on the vertical line array (VLA) of sensors: (A) Software and hardware upgrades to the data logger for the prototype vertical line array, including enhanced programmable gains, increased sampling rates, improved surface communications, (B) Cabling upgrade to allow installation of positioning sensors, (C) Adaptation of SDI's Angulate program to use acoustic slant ranges and DGPS data to compute and map the bottom location of the vertical array, (D) Progress in T''0'' delay and timing issues for improved control in data recording, (E) Successful deployment and recovery of the VLA twice during an October, 2003 cruise, once in 830m water, once in 1305m water, (F) Data collection and recovery from the DATS

  13. Geodetic Infrastructure in the Ibiza and Barcelona Harbours for Sea Level Monitoring

    Science.gov (United States)

    Martinez-Benjamin, J. J.; Gili, J.; Lopez, R.; Tapia, A.; Perez, B.; Pros, F.

    2013-12-01

    The presentation is directed to the description of the actual situation and relevant information of the geodetic infrastructure of Ibiza and Barcelona sites for sea level determination and contribution to regional sea level rise. Time series are being analysed for mean sea level variations www.puertos.es. .In the framework of a Spanish Space Project, the instrumentation of sea level measurements has been improved by providing the Barcelona site with a radar tide gauge Datamar 2000C from Geonica s.l. near an acoustic tide gauge. Puertos del Estado installed in 2007 a MIROS radar tide gauge and the Barcelona Harbour Authority a GPS referente station in the roof of the new Control Tower situated in the Energy Pier. The radar sensor is over the water surface, on a L-shaped structure which elevates it a few meters above the quay shelf. 1-min data are transmitted to the ENAGAS Control Center by cable and then sent each 1 min to Puertos del Estado by e-mail. There is a GPS station Leica Geosystems GRX1200 GG Pro and antenna 1202. Precision levelling has been made several times in the last two years because the tower is founded in reclaimed land. The measured settlement rate is about 1cm/year that may be could mask the values registered by the tide gauge. A description of the actual infrastructure at Ibiza harbour at Marina de Botafoch, is presented and its applications to sea level monitoring and altimeter calibration in support of the main CGPS at Ibiza harbour. It is described the geometrical precision levelling made in June 2013 between the radar tide gauge and the GPS station. In particular, the CGPS located at Ibiza harbour is essential for its application to the marine campaign Baleares 2013, near Ibiza island. The main objective is to determine the altimeter bias for Jason-2, about 9:09 UTC September 15, 2013, and Saral/AltiKa, about 05:30 UTC September 16, UTC. These activities has been received funding of the Ministerio de Ciencia e Innovacion under Spanish

  14. Support of Gulf of Mexico Hydrate Research Consortium: Activities to Support Establishment of a Sea Floor Monitoring Station Project

    Energy Technology Data Exchange (ETDEWEB)

    Carol Lutken

    2006-09-30

    The Gulf of Mexico Hydrates Research Consortium (GOM-HRC) was established in 1999 to assemble leaders in gas hydrates research. The Consortium is administered by the Center for Marine Resources and Environmental Technology, CMRET, at the University of Mississippi. The primary objective of the group is to design and emplace a remote monitoring station or sea floor observatory (MS/SFO) on the sea floor in the northern Gulf of Mexico by the year 2007, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission, although unavoidably delayed by hurricanes and other disturbances, necessitates assembling a station that will monitor physical and chemical parameters of the marine environment, including sea water and sea-floor sediments, on a more-or-less continuous basis over an extended period of time. In 2005, biological monitoring, as a means of assessing environmental health, was added to the mission of the MS/SFO. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in the arena of gas hydrates research. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. The observatory has now achieved a microbial dimension in addition to the geophysical, geological, and geochemical components it had already included. Initial components of the observatory, a probe that collects pore-fluid samples and another that records sea floor temperatures, were deployed in Mississippi Canyon 118 in May of 2005. Follow-up deployments, planned for fall 2005, had to be postponed due to the catastrophic effects of Hurricane Katrina (and later, Rita) on the Gulf Coast. Station/observatory completion, anticipated for 2007, will likely be delayed by at least one year. The CMRET has conducted several research cruises during this reporting period

  15. Groundwater Level Monitoring using Levelogger and the Importance of Long-Term Groundwater Level Data

    International Nuclear Information System (INIS)

    Nazran Harun; Ahmad Hasnulhadi Che Kamaruddin

    2016-01-01

    This review paper is focused on groundwater level monitoring using levelogger and the importance of long-term groundwater level data. The levelogger provides an inexpensive and convenient method to measure level, temperature and conductivity all in one probe. It can provide real time view as data is being recorded by the connected data logger. Water-level measurements from observation wells are the principal source of information about the hydrologic stresses acting on aquifers and how these stresses affect ground-water recharge, storage, and discharge. Long-term and systematic measurements of water levels provide essential data needed to evaluate changes in the resource over time to develop ground-water models, forecast trends and monitor the effectiveness of groundwater management. A significant advantage of this method of data collection and reporting are the groundwater level data can be updated real time. The accessibility of water level data is greatly enhanced by the Geographic Information System (GIS) to visually illustrate the locations of observation wells relative to relevant topographic, geologic, or hydrologic features. GIS and internet greatly enhance the capability for retrieval and transmittal of water-level data to potential users. (author)

  16. SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION PROJECT

    Energy Technology Data Exchange (ETDEWEB)

    Paul Higley; J. Robert Woolsey; Ralph Goodman; Vernon Asper; Boris Mizaikoff; Angela Davis

    2005-09-01

    A Consortium, designed to assemble leaders in gas hydrates research, has been established at the University of Mississippi's Center for Marine Resources and Environmental Technology, CMRET. The primary objective of the group is to design and emplace a remote monitoring station on the sea floor in the northern Gulf of Mexico by the year 2005, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission necessitates assembling a station that will monitor physical and chemical parameters of the sea water and sea floor sediments on a more-or-less continuous basis over an extended period of time. Development of the station allows for the possibility of expanding its capabilities to include biological monitoring, as a means of assessing environmental health. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in this relatively new research arena. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. Noteworthy achievements six months into the extended life of this cooperative agreement include: (1) Progress on the vertical line array (VLA) of sensors: Analysis and repair attempts of the VLA used in the deep water deployment during October 2003 have been completed; Definition of an interface protocol for the VLA DATS to the SFO has been established; Design modifications to allow integration of the VLA to the SFO have been made; Experience gained in the deployments of the first VLA is being applied to the design of the next VLAs; One of the two planned new VLAs being modified to serve as an Oceanographic Line Array (OLA). (2) Progress on the Sea Floor Probe: The decision to replace the Sea Floor Probe technology with the borehole emplacement of a geophysical array was reversed due to the 1300m water depth at the

  17. SUPPORT OF GULF OF MEXICO HYDRATE RESEARCH CONSORTIUM: ACTIVITIES TO SUPPORT ESTABLISHMENT OF A SEA FLOOR MONITORING STATION PROJECT

    Energy Technology Data Exchange (ETDEWEB)

    Paul Higley; J. Robert Woolsey; Ralph Goodman; Vernon Asper; Boris Mizaikoff; Angela Davis

    2005-11-01

    A Consortium, designed to assemble leaders in gas hydrates research, has been established at the University of Mississippi's Center for Marine Resources and Environmental Technology, CMRET. The primary objective of the group is to design and emplace a remote monitoring station on the sea floor in the northern Gulf of Mexico by the year 2005, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission necessitates assembling a station that will monitor physical and chemical parameters of the sea water and sea floor sediments on a more-or-less continuous basis over an extended period of time. Development of the station allows for the possibility of expanding its capabilities to include biological monitoring, as a means of assessing environmental health. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in this relatively new research arena. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. Noteworthy achievements one year into the extended life of this cooperative agreement include: (1) Progress on the vertical line array (VLA) of sensors: (1a) Repair attempts of the VLA cable damaged in the October >1000m water depth deployment failed; a new design has been tested successfully. (1b) The acoustic modem damaged in the October deployment was repaired successfully. (1c) Additional acoustic modems with greater depth rating and the appropriate surface communications units have been purchased. (1d) The VLA computer system is being modified for real time communications to the surface vessel using radio telemetry and fiber optic cable. (1e) Positioning sensors--including compass and tilt sensors--were completed and tested. (1f) One of the VLAs has been redesigned to collect near sea floor geochemical data. (2

  18. Monitoring of air pollution levels related to Charilaos Trikoupis Bridge.

    Science.gov (United States)

    Sarigiannis, D A; Handakas, E J; Kermenidou, M; Zarkadas, I; Gotti, A; Charisiadis, P; Makris, K; Manousakas, M; Eleftheriadis, K; Karakitsios, S P

    2017-12-31

    Charilaos Trikoupis bridge is the longest cable bridge in Europe that connects Western Greece with the rest of the country. In this study, six air pollution monitoring campaigns (including major regulated air pollutants) were carried out from 2013 to 2015 at both sides of the bridge, located in the urban areas of Rio and Antirrio respectively. Pollution data were statistically analyzed and air quality was characterized using US and European air quality indices. From the overall campaign, it was found that air pollution levels were below the respective regulatory thresholds, but once at the site of Antirrio (26.4 and 52.2μg/m 3 for PM 2.5 and ΡΜ 10 , respectively) during the 2nd winter period. Daily average PM 10 and PM 2.5 levels from two monitoring sites were well correlated to gaseous pollutant (CO, NO, NO 2 , NO x and SO 2 ) levels, meteorological parameters and factor scores from Positive Matrix Factorization during the 3-year period. Moreover, the elemental composition of PM 10 and PM 2.5 was used for source apportionment. That analysis revealed that major emission sources were sulfates, mineral dust, biomass burning, sea salt, traffic and shipping emissions for PM 10 and PM 2.5 , for both Rio and Antirrio. Seasonal variation indicates that sulfates, mineral dust and traffic emissions increased during the warm season of the year, while biomass burning become the dominant during the cold season. Overall, the contribution of the Charilaos Trikoupis bridge to the vicinity air pollution is very low. This is the result of the relatively low daily traffic volume (~10,000 vehicles per day), the respective traffic fleet composition (~81% of the traffic fleet are private vehicles) and the speed limit (80km/h) which does not favor traffic emissions. In addition, the strong and frequent winds further contribute to the rapid dispersion of the emitted pollutants. Copyright © 2017. Published by Elsevier B.V.

  19. Web Monitoring of EOS Front-End Ground Operations, Science Downlinks and Level 0 Processing

    Science.gov (United States)

    Cordier, Guy R.; Wilkinson, Chris; McLemore, Bruce

    2008-01-01

    This paper addresses the efforts undertaken and the technology deployed to aggregate and distribute the metadata characterizing the real-time operations associated with NASA Earth Observing Systems (EOS) high-rate front-end systems and the science data collected at multiple ground stations and forwarded to the Goddard Space Flight Center for level 0 processing. Station operators, mission project management personnel, spacecraft flight operations personnel and data end-users for various EOS missions can retrieve the information at any time from any location having access to the internet. The users are distributed and the EOS systems are distributed but the centralized metadata accessed via an external web server provide an effective global and detailed view of the enterprise-wide events as they are happening. The data-driven architecture and the implementation of applied middleware technology, open source database, open source monitoring tools, and external web server converge nicely to fulfill the various needs of the enterprise. The timeliness and content of the information provided are key to making timely and correct decisions which reduce project risk and enhance overall customer satisfaction. The authors discuss security measures employed to limit access of data to authorized users only.

  20. Impact of secondary inorganic aerosol and road traffic at a suburban air quality monitoring station.

    Science.gov (United States)

    Megido, L; Negral, L; Castrillón, L; Fernández-Nava, Y; Suárez-Peña, B; Marañón, E

    2017-03-15

    PM10 from a suburban site in the northwest of Spain was assessed using data from chemical determinations, meteorological parameters, aerosol maps and five-day back trajectories of air masses. Temporal variations in the chemical composition of PM10 were subsequently related to stationary/mobile local sources and long-range transport stemming from Europe and North Africa. The presence of secondary inorganic species (sulphates, nitrates and ammonium) in airborne particulate matter constituted one of the main focuses of this study. These chemical species formed 16.5% of PM10 on average, in line with other suburban background sites in Europe. However, a maximum of 47.8% of PM10 were recorded after several days under the influence of European air masses. Furthermore, the highest values of these three chemical species coincided with episodes of poor air circulation and influxes of air masses from Europe. The relationship between SO 4 2- and NH 4 + (R 2  = 0.57, p-valueforest fires. On isolated days, combustion was estimated to contribute up to 21.0 μg PM/m 3 (50.8% of PM10). The contribution from industrial processes to this source is also worth highlighting given the presence of Ni and Co in its profile. Furthermore, African dust outbreaks at the sampling site, characterised by an arc through the Atlantic Ocean, were usually associated with a higher concentration of Al 2 O 3 in PM10. Results evidenced the relevance of stationary (i.e., steelworks and thermal power station) and mobile sources in the air quality at the suburban site under study, with important apportionments of particulate matter coming from road traffic and as consequence of releasing precursor gases of secondary particles to the atmosphere. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Reactor Emergency Action Level Monitor: Knowledge acquisition experiences

    International Nuclear Information System (INIS)

    Touchton, R.A.

    1987-01-01

    This paper presents the Knowledge Acquisition experiences in developing the Reactor Emergency Action Level Monitor (REALM) Expert System Prototype. REALM is an expert system which interprets plant sensor data and provides advice on the proper emergency classification. The REALM project is being funded by the Electric Power Research Institute, Consolidated Edison is serving as the host utility, and the effort is being conducted by Technology Applications, Inc. REALM is being designed to provide expert assistance in the identification of a nuclear power plant emergency situation and the determination of its severity, ultimately operating in a real-time, on-line processing environment. The paper discusses briefly the direct knowledge acquisition techniques used by the project team (who are themselves power industry engineers), to extract relevant knowledge from plant specifications and procedures

  2. The development of gate monitor for low level radioactive waste

    International Nuclear Information System (INIS)

    Fujisawa, Morio; Watanabe, Michito; Kato, Tatsuo

    1994-01-01

    Low-level radioactive waste (LLW) generated from nuclear power plants in Japan, have been deposited in the yard of each power plant. At present, it is stored in about 500,000 drum cans (200l each). These drum cans are carried to Mutsu-ogawara Port by special transport ships and then transferred to Rokkasho LLW transport trucks (special vehicles) for storage. The gate monitor is used to automatically measure the dose rate on the vehicles loaded with transport vessels from a remote location, to ensure the safe transportation from Mutsu-ogawara Port the Burying Center. It is a new system which has been developed for effective measurement of dose rate on a number of transport vessels in a short time. This system is the first in the world for measuring dose rate on vehicles. Such a system cannot be found in any country of the world. (author)

  3. Monitoring of radioactivity in the environs of Finnish nuclear power stations in 1987

    International Nuclear Information System (INIS)

    Sjoeblom, K.-L.; Klemola, S.; Ilus, E.; Arvela, H.; Blomqvist, L.

    1989-06-01

    Results of the environmental programmes for monitoring radioactive contamination around Finnish nuclear power plants in 1987 are reported. Fallout from the Chernobyl accident, which took place in April 1986, was still dominating the artificial radiation situation in Finland. Thus, large amounts of 137 Cs and other long-lived fallout nuclides predominated in the environmental samples taken in the vicinity of nuclear power plants. The extremely small airborne releases from Finnish nuclear power plants were almost totally covered by fallout nuclides. The somewhat higher aquatic releases were easier to distinguish, and it was possible to follow their spread in the marine environment. The contribution of locally discharged nuclides to radiation doses of the population was insignificant

  4. Sensing loop performance monitoring in the safety systems of nuclear power stations

    International Nuclear Information System (INIS)

    Colley, R.C.; Widmeyer, M.; Weiss, J.H.; Wiegle, H.R.

    1991-01-01

    This paper reports on plant technical specifications and NRC regulatory guides which require testing of sensing loops to detect degradation and failure. Industry efforts have focused on specific manual testing to detect individual failure modes such as increased response time and calibration drift. Recent work performed by EPRI and by others using instrument loop data, failure modes, and effects analyses (FMEAs), and experience with utility on-line sensor health monitoring programs has established qualitative physical models of the sensing loop. This methodology has demonstrated that sensing loop cross comparison techniques can provide equivalent indication of sensing loop performance. It also provides more frequent sensing loop health indication than manual testing and reduces the requirement for manual testing

  5. Mechanical guided waves for fuel level monitoring system

    Directory of Open Access Journals (Sweden)

    Tiberiu Adrian SALAORU

    2017-09-01

    Full Text Available The mechanical guided waves have a wide range of applications in many types of equipment and devices. The fuel level is an important parameter which needs to be monitored for a vehicle which can be a space vehicle, an aircraft or any other. For this purpose mechanical guided waves can be used as they have several major advantages over any other methods. There are a wide ultrasonic sensors used for this purpose but in the most cases the mechanical waves are traveling through air or fuel for measuring their level. In general the wave propagation through a single media at a time is utilized. The method described in this work uses the propagation of the mechanical guided waves through two different media in the same time. The propagating media is the container wall and the other is the fuel. One of the advantages of this method is the reduction of the measurement errors when the incident angle to the fuel level surface is different from 90 degree. These situations could occur when the fuel tank is tilted or when the fuel surface is not flat. This measurement method will not be affected by these conditions.

  6. Two-Level Control for Fast Electrical Vehicle Charging Stations with Multi Flywheel Energy Storage System

    DEFF Research Database (Denmark)

    SUN, BO; Dragicevic, Tomislav; Vasquez, Juan Carlos

    2015-01-01

    This paper applies a hierarchical control for a fast charging station (FCS) composed of paralleled PWM rectifier and dedicated paralleled multiple flywheel energy storage systems (FESSs), in order to mitigate peak power shock on grid caused by sudden connection of electrical vehicle (EV) chargers...

  7. Evaluation of 25 Y of environmental monitoring data around Madras atomic power station (MAPS), Kalpakkam (India)

    International Nuclear Information System (INIS)

    Rajaram, S.; Brindha, J. T.; Sreedevi, K. R.; Manu, A.; Thilakavathi, A.; Ramkumar, S.; Santhanakrishnan, V.; Balagurunathan, M. R.; Jesan, T.; Kannan, V.; Hegde, A. G.

    2010-01-01

    The Environmental Survey Laboratory at Kalpakkam (India) carries out elaborate monitoring programme involving atmospheric, terrestrial and aquatic samples for radioactivity to evaluate the impact of operating two pressurised heavy water reactors. This paper presents the evaluation of 25 y (1983-2008) data. Statistical analysis of the environmental data for different radionuclides showed that the data best fits log-normal distribution. The data analysed showed that fission products such as 137 Cs, 90 Sr and 131 I were due to global fallout only. A ratio of 0.2 was obtained for 90 Sr to 137 Cs in air filter samples, only during Chernobyl accident period. The transfer factor of 137 Cs and 90 Sr for rice was computed to be 0.23 and 0.03 and vegetables 0.25 and 0.10, respectively. Activation products 3 H and 41 Ar are the only radionuclides that are related to MAPS operation. A strong correlation (r = 0.9) was observed between 3 H activity in air and 3 H discharged to the atmosphere. A similar correlation (r = 0.8) was observed in 3 H concentration in seawater and 3 H discharged in the liquid waste. The annual internal dose due to 3 H and annual external dose due to 41 Ar evaluated in the last 25 y show that the members of the public received less than 2% of the dose limit (1 mSv y -1 ) set by ICRP 72. (authors)

  8. Field experience with advanced methods of on-line monitoring of water chemistry and corrosion degradation in nuclear power stations

    International Nuclear Information System (INIS)

    Stellwag, B.; Aaltonen, P.; Hickling, J.

    1997-01-01

    Advanced methods for on-line, in-situ water chemistry and corrosion monitoring in nuclear power stations have been developed during the past decade. The terms ''on-line'' and ''in-situ'' characterize approaches involving continuous measurement of relevant parameters in high temperature water, preferably directly in the systems and components and not in removed samples at room temperature. This paper describes the field experience to-date with such methods in terms of three examples: (1) On-line chemistry monitoring of the primary coolant during shutdown of a Type WWER-440 PWR. (2) Redox and corrosion potential measurements in final feedwater preheaters and steam generators of two large KWU PWRs over several cycles of plant operation. (3) Real-time, in-situ corrosion surveillance inside the calundia vault of a CANDU reactor. The way in which water chemistry sensors and corrosion monitoring sensors complement each other is outlined: on-line, in-situ measurement of pH, conductivity and redox potential gives information about the possible corrosivity of the environment. Electrochemical noise techniques display signals of corrosion activity under the actual environmental conditions. A common experience gained from separate use of these different types of sensors has been that new and additional information about plants and their actual process conditions is obtained. Moreover, they reveal the intimate relationship between the operational situation and its consequences for the quality of the working fluid and the corrosion behaviour of the plant materials. On this basis, the efficiency of the existing chemistry sampling and control system can be checked and corrosion degradation can be minimized. Furthermore, activity buildup in the primary circuit can be studied. Further significant advantages can be expected from an integration of these various types of sensors into a common water chemistry and corrosion surveillance system. For confirmation, a complete set of sensors

  9. Field experience with advanced methods of on-line monitoring of water chemistry and corrosion degradation in nuclear power stations

    Energy Technology Data Exchange (ETDEWEB)

    Stellwag, B [Siemens AG Unternehmensbereich KWU, Erlangen (Germany); Aaltonen, P [Technical Research Centre of Finland, Espoo (Finland); Hickling, J [CML GmbH, Erlangen (Germany)

    1997-02-01

    Advanced methods for on-line, in-situ water chemistry and corrosion monitoring in nuclear power stations have been developed during the past decade. The terms ``on-line`` and ``in-situ`` characterize approaches involving continuous measurement of relevant parameters in high temperature water, preferably directly in the systems and components and not in removed samples at room temperature. This paper describes the field experience to-date with such methods in terms of three examples: (1) On-line chemistry monitoring of the primary coolant during shutdown of a Type WWER-440 PWR. (2) Redox and corrosion potential measurements in final feedwater preheaters and steam generators of two large KWU PWRs over several cycles of plant operation. (3) Real-time, in-situ corrosion surveillance inside the calundia vault of a CANDU reactor. The way in which water chemistry sensors and corrosion monitoring sensors complement each other is outlined: on-line, in-situ measurement of pH, conductivity and redox potential gives information about the possible corrosivity of the environment. Electrochemical noise techniques display signals of corrosion activity under the actual environmental conditions. A common experience gained from separate use of these different types of sensors has been that new and additional information about plants and their actual process conditions is obtained. Moreover, they reveal the intimate relationship between the operational situation and its consequences for the quality of the working fluid and the corrosion behaviour of the plant materials. On this basis, the efficiency of the existing chemistry sampling and control system can be checked and corrosion degradation can be minimized. Furthermore, activity buildup in the primary circuit can be studied. Further significant advantages can be expected from an integration of these various types of sensors into a common water chemistry and corrosion surveillance system. (Abstract Truncated)

  10. MONITORING AND CONTROLLING ON SURFACE SETTLEMENT IN SAND AND GRAVEL STRATA CAUSED BY SUBWAY STATION CONSTRUCTION APPLYING PIPE-ROOF PRE-CONSTRUCTION METHOD (PPM

    Directory of Open Access Journals (Sweden)

    Xian Yang

    2017-07-01

    Full Text Available Pipe-roof Pre-construction Method (PPM is regarded as a safer method to construct underground space, especially suitable for the construction sites with dense surface buildings, underground pipelines and complicated geological conditions. Xinleyizhi Station of Shenyang Metro constructed by PPM. In order to ensure safety in construction, the whole construction process was closely monitored. In this paper, monitoring results of surface settlement in PPM is analyzed. According to the monitoring results, the most serious settlement occurred in pipes jacking, which was the first and the most crucial step in PPM. The settlement reasons in each step are discussed, and controlling methods of surface settlement in each step are elaborated. Through close monitoring and timely control, the construction of Xinleyizhi Station completed smoothly. Because of the obvious advantages of PPM, the method will be used more widely in construction of shallow buried excavation under complicated surrounding and geological conditions.

  11. Monitoring surface-water quality in Arizona: the fixed-station network

    Science.gov (United States)

    Tadayon, Saeid

    2000-01-01

    Arizona is an arid State in which economic development is influenced largely by the quantity and quality of water and the location of adequate water supplies. In 1995, surface water supplied about 58 percent of total withdrawals in Arizona. Of the total amount of surface water used in 1995, about 89 percent was for agriculture, 10 percent for public supply, and 1 percent for industrial supply (including mining and thermoelectric; Solley and others, 1998). As a result of rapid population growth in Arizona, historic agricultural lands in the Phoenix (Maricopa County) and Tucson (Pima County) areas are now being developed for residential and commercial use; thus, the amount of water used for public supply is increasing. The Clean Water Act was established by U.S. Congress (1972) in response to public concern about water-pollution control. The act defines a process by which the United States Congress and the citizens are informed of the Nation’s progress in restoring and maintaining the quality of our waters. The Arizona Department of Environmental Quality (ADEQ) is the State-designated agency for this process and, as a result, has developed a monitoring program to assess water quality in Arizona. The ADEQ is required to submit a water-quality assessment report to the United States Environmental Protection Agency (USEPA) every 2 years. The USEPA summarizes the reports from each State and submits a report to the Congress characterizing water quality in the United States. These reports serve to inform Congress and the public of the Nation’s progress toward the restoration and maintenance of water quality in the United States (Arizona Department of Environmental Quality, 1998).

  12. Sea level hazards: Altimetric monitoring of tsunamis and sea level rise

    Science.gov (United States)

    Hamlington, Benjamin Dillon

    Whether on the short timescale of an impending tsunami or the much longer timescale of climate change-driven sea level rise, the threat stemming from rising and inundating ocean waters is a great concern to coastal populations. Timely and accurate observations of potentially dangerous changes in sea level are vital in determining the precautionary steps that need to be taken in order to protect coastal communities. While instruments from the past have provided in situ measurements of sea level at specific locations across the globe, satellites can be used to provide improved spatial and temporal sampling of the ocean in addition to producing more accurate measurements. Since 1993, satellite altimetry has provided accurate measurements of sea surface height (SSH) with near-global coverage. Not only have these measurements led to the first definitive estimates of global mean sea level rise, satellite altimetry observations have also been used to detect tsunami waves in the open ocean where wave amplitudes are relatively small, a vital step in providing early warning to those potentially affected by the impending tsunami. The use of satellite altimetry to monitor two specific sea level hazards is examined in this thesis. The first section will focus on the detection of tsunamis in the open ocean for the purpose of providing early warning to coastal inhabitants. The second section will focus on estimating secular trends using satellite altimetry data with the hope of improving our understanding of future sea level change. Results presented here will show the utility of satellite altimetry for sea level monitoring and will lay the foundation for further advancement in the detection of the two sea level hazards considered.

  13. Modeling of Coastal Inundation, Storm Surge, and Relative Sea-Level Rise at Naval Station Norfolk, Norfolk, Virginia, USA

    Science.gov (United States)

    2013-01-01

    Storm Surge, and Relative Sea-Level Rise at Naval Station Norfolk, Norfolk, Virginia, USA 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT...tive comments on the manuscript. Permission was granted by the Chief, USACE, to publish this information. LITERATURE CITED Blanton, B.; Stillwell, L...Geospatial Center. http://www.agc.army.mil/ (accessed February 29, 2012). Vickery, P.; Wadhera, D.; Cox, A.; Cardone , V.; Hanson, J., and Blanton, B

  14. Evaluation of The Data of Duzce Air Quality Monitoring Station Between 2007-2011

    Directory of Open Access Journals (Sweden)

    Atilla Senih Mayda

    2013-02-01

    Full Text Available Background: To evaluate air quality between the years 2007-2011 in the province of Duzce. Methods: Inthis cross-sectional study, sulfur dioxide, particulate matter levels, wind speed, air temperature, wind direction, relative humidity, air pressure values of Duzce city center obtained from the web page of Ministry of Envoriment and Planning between 2007-2011 were studied. Ontained measurements compared with the limit values of Air Quality Protection Regulation and the European Union. Results: Average PM10 was 90,5±1,9 (minimum 11,maximum 612 in Duzce Province from January 30, 2007 to December 2011. For PM10 long-term limit value for Turkey was 78 µg/mm3 and were exceeded all years. Winter seasons had higher average values of PM10 than summer seasons. The average SO2 was 12,5±0,3 (minimum 1, maximum 56. Long-term limit value and average annual values of Turkey for SO2 were not exceeded in any year. Conclusion:Duzce Directorate of Environment and Urban Planning should increase the controls in Duzce,especially due to higher values for PM10 parameter related to air pollution.In the days when warning theshold levels exceeded necessary measuress must be taken. [TAF Prev Med Bull 2013; 12(1.000: 11-18

  15. Testing the sampling efficiency of a nuclear power station stack monitor

    Energy Technology Data Exchange (ETDEWEB)

    Stroem, L.H. [Instrumentinvest, Nykoeping (Sweden)

    1997-08-01

    The test method comprises the injection of known amounts of monodisperse particles in the stack air stream, at a suitable point upstream of the sampling installation. To find a suitable injection polls, the gas flow was mapped by means of a tracer gas, released in various points in the stack base. The resulting concentration distributions at the stack sampler level were observed by means of an array of gas detectors. An injection point that produced symmetrical distribution over the stack area, and low concentrations at the stack walls was selected for the particle tests. Monodisperse particles of 6, 10, and 19 {mu}m aerodynamic diameter, tagged with dysprosium, were dispersed in the selected injection point. Particle concentration at the sampler level was measured. The losses to the stack walls were found to be less than 10 %. The particle concentrations at the four sampler inlets were calculated from the observed gas distribution. The amount calculated to be aspirated into the sampler piping was compared with the quantity collected by the sampling train ordinary filter, to obtain the sampling line transmission efficiency. 1 ref., 2 figs.

  16. Safety analysis report: A comparison of incidents from Safety Years 2006 through 2010, USDA Forest Service, Rocky Mountain Research Station Inventory and Monitoring Program

    Science.gov (United States)

    Devon Donahue

    2012-01-01

    This paper is an analysis of 5 years of accident data for the USDA Forest Service, Rocky Mountain Research Station (RMRS) Inventory and Monitoring (IM) Program that identifies past trends, allows for standardized self-comparison, and increases our understanding of the true costs of injuries and accidents. Measuring safety is a difficult task. While most agree that...

  17. Expert Water Quality Panel Review of Responses to the NASA Request for Information for the International Space Station On-Board Environmental Monitoring System

    Science.gov (United States)

    Fishman, Julianna L.; Mudgett, Paul D.; Packham, Nigel J.; Schultz, John R.; Straub, John E., II

    2005-01-01

    On August 9, 2003, NASA, with the cooperative support of the Vehicle Office of the International Space Station Program, the Advanced Human Support Technology Program, and the Johnson Space Center Habitability and Environmental Factors Office released a Request for Information, or RFI, to identify next-generation environmental monitoring systems that have demonstrated ability or the potential to meet defined requirements for monitoring air and water quality onboard the International Space Station. This report summarizes the review and analysis of the proposed solutions submitted to meet the water quality monitoring requirements. Proposals were to improve upon the functionality of the existing Space Station Total Organic Carbon Analyzer (TOCA) and monitor additional contaminants in water samples. The TOCA is responsible for in-flight measurement of total organic carbon, total inorganic carbon, total carbon, pH, and conductivity in the Space Station potable water supplies. The current TOCA requires hazardous reagents to accomplish the carbon analyses. NASA is using the request for information process to investigate new technologies that may improve upon existing capabilities, as well as reduce or eliminate the need for hazardous reagents. Ideally, a replacement for the TOCA would be deployed in conjunction with the delivery of the Node 3 water recovery system currently scheduled for November 2007.

  18. Forsmark site investigation. Monitoring of brook water levels, electrical conductivities, temperatures and discharges January-December 2009

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, Per-Olof (Artesia Grundvattenkonsult (Sweden)); Juston, John (Juston Konsult (Sweden))

    2011-03-15

    This document reports the monitoring of water levels, electrical conductivities, temperatures and discharges at four brook discharge gauging stations, and the monitoring of water electrical conductivity at the outlet of Lake Bolundsfjaerden in the Forsmark area. The report presents data from 1 January through 31 December 2009 and is a continuation of reporting from Johansson and Juston (2007, 2009), which covered the periods from 1 April 2004 through 31 March 2007 and 1 April 2007 through 31 December 2008, respectively. Long-throated flumes equipped with automatically recording devices were used for the discharge measurements. Every c. 14 days the water depths at the upstream edge of the flumes were measured manually by a ruler as a check. Electrical conductivity and temperature were automatically recorded and these parameters were also measured manually every c. 14 days with the site investigation field devices. SKB's Hydro Monitoring System (HMS) was used to collect and store all data. From HMS quality assured data were transferred to SKB's primary database Sicada. Measurements of levels, electrical conductivities and temperatures were made every 10 minutes (every 30 minutes for electrical conductivity at the outlet of Lake Bolundsfjaerden). For the calculation of discharge, quality assured water level data from the flumes were used. The calculation procedure included consolidation of the time series to hourly averages, screening of data for removal of short-term spikes, noise and other data that were judged erroneous. After the calculations were performed, the results were delivered to Sicada. The amplitudes of water level variations during this reporting period were 0.26-0.33 m at the four stations. The mean electrical conductivities varied between 26 and 41 mS/m at the four discharge stations. The electrical conductivity at the outlet of Lake Bolundsfjaerden varied between 53 and 188 mS/m during the period with the higher values at the end of the

  19. The environmental radiation monitoring system and in-situ measurements for early notification and OIL (Operational Intervention Levels) calculations

    International Nuclear Information System (INIS)

    Haquin, G.; Ne'eman, E.; Brenner, S.; Lavi, N.

    1997-01-01

    The efficiency of the environmental radiation monitoring, low level laboratory and in-situ gamma-ray spectrometry are evaluated as the systems for early notification and for determination of dose rate in air, surface contamination and activity concentration in food during emergencies for Operational Intervention Levels (OIL) recalculation.The National Environmental Radiation Monitoring System has proved its efficiency in the early detection of unregistered radiography work. A mobile station of the network can be used for absorbed dose rate measurement during emergencies in contaminated areas. The calibrated in-situ gamma-ray spectrometry system in an open phosphate ore mine has showed the efficiency of this technique for fast and accurate determination of soil activity concentration. The calibration for an uniform depth distribution can be easily mathematically converted to an exponential depth distribution in cases of radioactive material fallout

  20. Environmental monitoring considerations for low-level waste disposal sites

    International Nuclear Information System (INIS)

    Sedlet, J.

    1982-01-01

    All waste disposal sites are required to monitor the environment. The proposed NRC licensing rule, 10 CFR Part 61, requires that such monitoring be conducted before, during, and after a site is operated. An adequate monitoring program consists of measuring concentrations of radionuclides, chemically-toxic substances, and leachate indicators in environmental media and of evaluating specific physical properties of the site. In addition, the composition of the buried waste must be known. Methods for obtaining this information are discussed and monitoring programs are presented for the preoperational, operational, and postclosure phases of a disposal site. Environmental monitoring is considered in a broad context, since it includes monitoring burial trenches onsite, as well as surveillance in the offsite environment. Postclosure monitoring programs will be strongly influenced by the operational monitoring results. In some respects, this phase will be easier since the migration pathways should be well known and the number of radionuclides of concern reduced by radioactive decay. The results of the environmental monitoring program will be vital to successful site operation. These results should be used to determine if operational changes are needed and to predict future environmental impacts

  1. A Low Level Radioactivity Monitor for Aqueous Waste

    International Nuclear Information System (INIS)

    Quirk, E.J.M.

    1968-04-01

    A system is described for continuous monitoring of very low levels of radioactivity in waste water containing typically 3.5 g/l dissolved solids. Spray evaporation of the water enables the dissolved solids to be recovered in the form of an aerosol and collected on a filter tape where the radioactivity is measured by a radiation detector. The advantage of this method compared with a direct measurement is that the attenuating effect of the water is removed and thus greater sensitivity is obtained. Compensation for background and any contamination is achieved by feeding distilled water to the aerosol generator every alternate sampling period and recording the count difference between two successive sampling periods . A printed record of the totalised count difference is obtained once per hour during the integration time of one month. For β radioactivity the minimum values of specific activity measurable extend from 1 x 10 -6 Ci/m 3 to 6 x 10 -8 Ci/m depending on the B end-point energy in the range 167 KeV to 2.26 MeV. The estimated minimum measurable specific activity is 6 x 10 -8 Ci/m 3

  2. A Low Level Radioactivity Monitor for Aqueous Waste

    Energy Technology Data Exchange (ETDEWEB)

    Quirk, E J.M.

    1968-04-15

    A system is described for continuous monitoring of very low levels of radioactivity in waste water containing typically 3.5 g/l dissolved solids. Spray evaporation of the water enables the dissolved solids to be recovered in the form of an aerosol and collected on a filter tape where the radioactivity is measured by a radiation detector. The advantage of this method compared with a direct measurement is that the attenuating effect of the water is removed and thus greater sensitivity is obtained. Compensation for background and any contamination is achieved by feeding distilled water to the aerosol generator every alternate sampling period and recording the count difference between two successive sampling periods . A printed record of the totalised count difference is obtained once per hour during the integration time of one month. For {beta} radioactivity the minimum values of specific activity measurable extend from 1 x 10{sup -6} Ci/m{sup 3} to 6 x 10{sup -8} Ci/m depending on the B end-point energy in the range 167 KeV to 2.26 MeV. The estimated minimum measurable specific activity is 6 x 10{sup -8} Ci/m{sup 3}.

  3. Beaver Valley Power Station and Shippingport Atomic Power Station. 1984 Annual environmental report, radiological. Volume 2

    International Nuclear Information System (INIS)

    1985-01-01

    This report describes the Radiological Environmental Monitoring Program conducted during 1984 in the vicinity of the Beaver Valley Power Station and the Shippingport Atomic Power Station. The Radiological Environmental Program consists of on-site sampling of water and gaseous effluents and off-site monitoring of water, air, river sediments, soils, food pathway samples, and radiation levels in the vicinity of the site. This report discusses the results of this monitoring during 1984. The environmental program outlined in the Beaver Valley Power Station Technical Specifications was followed throughout 1984. The results of this environmental monitoring program show that Shippingport Atomic Power Station and Beaver Valley Power Station operations have not adversely affected the surrounding environment. 23 figs., 18 tabs

  4. Monitoring and assessment of health issues at energy plant and gas station Pak steel bin Qasim Karachi

    International Nuclear Information System (INIS)

    Memon, Z.

    2005-01-01

    No doubt Environmental and health safety issues in big cities of Pakistan are developing havoc problems due to mechanized operations by emitting flue gases, effluent and acoustic noise, which it is my topic to discuss in detail. Acoustic noise is one of the major environmental problems in Industrial Plants. The noise study under taken in detail at feed pumps, super heater, exhausters and accumulators of Energy plant (E.P) as the regulators, control room etc. of Gas station (G.S) Pak Steel Bin Qasim Karachi. In light of permissible occupational noise exposure limits, as allowed by the ISO,EEC and other National Standards, some recommendations have been made to provide safety measures for workers against high level noise health hazards like head ache, hearing problem, Irritation, accidents at work, tension, disturbance to work and so many physiological and psychological effects, along with guidelines to overcome the break downs an improve efficiency of the plants. (Orig./A.B.)

  5. A system for radiation monitoring at the site for emergency planning and response in a nuclear station potentialities and prospects

    International Nuclear Information System (INIS)

    Novakov, V.; Moskovska, N.; Madzharov, M.; Angelov, V.

    1993-01-01

    The paper describes the existing system for radiation monitoring of the NPP region. The location of the devices puts a number of problems as maintenance of the radiometric equipment and urgent collecting and processing of the measuring data. Undeniably, to get an effective and timely decision, it is necessary to have on hand information as complete and prompt as possible, about the radiological situation in the regions, towns, villages and sites. As a result of daily observation and registration, an amount of enough in volume data could be accumulated. This data may be used as a base in case of a sudden change of the radiological situation and/or in case of arising of some local contaminations as a result of a volley type of emission, accidents at the nuclear power stations and releases fractions of radioactive and rare gases. The data obtained for a comparatively large region (about 700 square kilometers) with a high degree of gamma detectors distribution density are discussed. In the conditions of a progressively complicating radiological situation, they allow to determine the possible directions of the emission and also to undertake some response actions for protection of the population in time. (author)

  6. Radiofrequency radiation from nearby base stations gives high levels in an apartment in Stockholm, Sweden: A case report

    Science.gov (United States)

    Hardell, Lennart; Carlberg, Michael; Hedendahl, Lena K.

    2018-01-01

    Exposure to radiofrequency (RF) radiation was classified in 2011 as a possible human carcinogen, Group 2B, by the International Agency for Research on Cancer of the World Health Organisation. Evidence of the risk of cancer risk has since strengthened. Exposure is changing due to the rapid development of technology resulting in increased ambient radiation. RF radiation of sufficient intensity heats tissues, but the energy is insufficient to cause ionization, hence it is called non-ionizing radiation. These non-thermal exposure levels have resulted in biological effects in humans, animals and cells, including an increased cancer risk. In the present study, the levels of RF radiation were measured in an apartment close to two groups of mobile phone base stations on the roof. A total of 74,531 measurements were made corresponding to ~83 h of recording. The total mean RF radiation level was 3,811 µW/m2 (range 15.2–112,318 µW/m2) for the measurement of the whole apartment, including balconies. Particularly high levels were measured on three balconies and 3 of 4 bedrooms. The total mean RF radiation level decreased by 98% when the measured down-links from the base stations for 2, 3 and 4 G were disregarded. The results are discussed in relation to the detrimental health effects of non-thermal RF radiation. Due to the current high RF radiation, the apartment is not suitable for long-term living, particularly for children who may be more sensitive than adults. For a definitive conclusion regarding the effect of RF radiation from nearby base stations, one option would be to turn them off and repeat the measurements. However, the simplest and safest solution would be to turn them off and dismantle them. PMID:29725476

  7. Radiofrequency radiation from nearby base stations gives high levels in an apartment in Stockholm, Sweden: A case report.

    Science.gov (United States)

    Hardell, Lennart; Carlberg, Michael; Hedendahl, Lena K

    2018-05-01

    Exposure to radiofrequency (RF) radiation was classified in 2011 as a possible human carcinogen, Group 2B, by the International Agency for Research on Cancer of the World Health Organisation. Evidence of the risk of cancer risk has since strengthened. Exposure is changing due to the rapid development of technology resulting in increased ambient radiation. RF radiation of sufficient intensity heats tissues, but the energy is insufficient to cause ionization, hence it is called non-ionizing radiation. These non-thermal exposure levels have resulted in biological effects in humans, animals and cells, including an increased cancer risk. In the present study, the levels of RF radiation were measured in an apartment close to two groups of mobile phone base stations on the roof. A total of 74,531 measurements were made corresponding to ~83 h of recording. The total mean RF radiation level was 3,811 µW/m 2 (range 15.2-112,318 µW/m 2 ) for the measurement of the whole apartment, including balconies. Particularly high levels were measured on three balconies and 3 of 4 bedrooms. The total mean RF radiation level decreased by 98% when the measured down-links from the base stations for 2, 3 and 4 G were disregarded. The results are discussed in relation to the detrimental health effects of non-thermal RF radiation. Due to the current high RF radiation, the apartment is not suitable for long-term living, particularly for children who may be more sensitive than adults. For a definitive conclusion regarding the effect of RF radiation from nearby base stations, one option would be to turn them off and repeat the measurements. However, the simplest and safest solution would be to turn them off and dismantle them.

  8. Oxidative Stress and Genotoxicity of Long-Term Occupational Exposure to Low Levels of BTEX in Gas Station Workers

    Directory of Open Access Journals (Sweden)

    Feng Xiong

    2016-12-01

    Full Text Available Atmospheric benzene, toluene, ethylbenzene, and xylenes (BTEX can lead to multiple health injuries. However, what remains uncertain is the effect of long-term exposure to low levels of BTEX. Thus, we determined the BTEX levels in the air from the refueling and office areas in gas stations. Then we collected workers’ (200 refueling vs. 52 office workers peripheral blood samples to analyze the serum total-superoxide dismutase (T-SOD, glutathione (GSH, malondialdehyde (MDA, and 8-hydroxydeoxyguanosine (8-OHdG levels. DNA damage was analyzed by the comet assay and micronucleus test in buccal epithelial cells. We found that the levels of BTEX in refueling areas were significantly higher than those in office areas (p < 0.001. The serum T-SOD and GSH of refueling workers were significantly lower than those in office workers (p < 0.001. By contrast, the serum MDA and 8-OHdG of refueling workers were significantly higher than those of office workers (p < 0.001, MDA; p = 0.025, 8-OHdG. Furthermore, tail and Olive tail moments in refueling workers were longer (p = 0.004, tail moment; p = 0.001, Olive tail moment, and the micronucleus rate was higher (p < 0.001 than those in office workers. Taken together, long-term exposure to low levels of BTEX may reduce the antioxidant ability and increase the risk of DNA damage in refueling workers of gas stations.

  9. Using a neural network approach and time series data from an international monitoring station in the Yellow Sea for modeling marine ecosystems.

    Science.gov (United States)

    Zhang, Yingying; Wang, Juncheng; Vorontsov, A M; Hou, Guangli; Nikanorova, M N; Wang, Hongliang

    2014-01-01

    The international marine ecological safety monitoring demonstration station in the Yellow Sea was developed as a collaborative project between China and Russia. It is a nonprofit technical workstation designed as a facility for marine scientific research for public welfare. By undertaking long-term monitoring of the marine environment and automatic data collection, this station will provide valuable information for marine ecological protection and disaster prevention and reduction. The results of some initial research by scientists at the research station into predictive modeling of marine ecological environments and early warning are described in this paper. Marine ecological processes are influenced by many factors including hydrological and meteorological conditions, biological factors, and human activities. Consequently, it is very difficult to incorporate all these influences and their interactions in a deterministic or analysis model. A prediction model integrating a time series prediction approach with neural network nonlinear modeling is proposed for marine ecological parameters. The model explores the natural fluctuations in marine ecological parameters by learning from the latest observed data automatically, and then predicting future values of the parameter. The model is updated in a "rolling" fashion with new observed data from the monitoring station. Prediction experiments results showed that the neural network prediction model based on time series data is effective for marine ecological prediction and can be used for the development of early warning systems.

  10. User Context Aware Base Station Power Flow Model

    OpenAIRE

    Walsh, Barbara; Farrell, Ronan

    2005-01-01

    At present the testing of power amplifiers within base station transmitters is limited to testing at component level as opposed to testing at the system level. While the detection of catastrophic failure is possible, that of performance degradation is not. This paper proposes a base station model with respect to transmitter output power with the aim of introducing system level monitoring of the power amplifier behaviour within the base station. Our model reflects the expe...

  11. Long open-path TDL based system for monitoring the background concentration for deployment at Jungfraujoch High Altitude Research Station- Switzerland

    Science.gov (United States)

    Simeonov, V.; van den Bergh, H.; Parlange, M. B.

    2009-12-01

    A new long-open-path instrument developed at EPFL for methane and water vapor observation will be presented. The instrument is developed and will be used within the GAW+ CH program and aims at long-term monitoring of background methane concentration at the High Altitude Research Station Jungfraujoch (3580 mASL). The instrument is built on the monostatic scheme (transceiver -distant retroreflector) using a 1.65 nm tunable diode laser (TDL) and a retroreflector at 1200 m from the transceiver. The data will be compared with in-situ measurements to evaluate the effect of the station on the in-situ data.

  12. Nanosecond-level time synchronization of autonomous radio detector stations for extensive air showers

    Science.gov (United States)

    The Pierre Auger Collaboration

    2016-01-01

    To exploit the full potential of radio measurements of cosmic-ray air showers at MHz frequencies, a detector timing synchronization within 1 ns is needed. Large distributed radio detector arrays such as the Auger Engineering Radio Array (AERA) rely on timing via the Global Positioning System (GPS) for the synchronization of individual detector station clocks. Unfortunately, GPS timing is expected to have an accuracy no better than about 5 ns. In practice, in particular in AERA, the GPS clocks exhibit drifts on the order of tens of ns. We developed a technique to correct for the GPS drifts, and an independent method is used to cross-check that indeed we reach a nanosecond-scale timing accuracy by this correction. First, we operate a ``beacon transmitter'' which emits defined sine waves detected by AERA antennas recorded within the physics data. The relative phasing of these sine waves can be used to correct for GPS clock drifts. In addition to this, we observe radio pulses emitted by commercial airplanes, the position of which we determine in real time from Automatic Dependent Surveillance Broadcasts intercepted with a software-defined radio. From the known source location and the measured arrival times of the pulses we determine relative timing offsets between radio detector stations. We demonstrate with a combined analysis that the two methods give a consistent timing calibration with an accuracy of 2 ns or better. Consequently, the beacon method alone can be used in the future to continuously determine and correct for GPS clock drifts in each individual event measured by AERA.

  13. Nanosecond-level time synchronization of autonomous radio detector stations for extensive air showers

    International Nuclear Information System (INIS)

    Aab, A.; Abreu, P.; Aglietta, M.; Ahn, E.J.; Al Samarai, I.; Albuquerque, I.F.M.; Allekotte, I.; Allison, P.; Almela, A.; Alvarez Castillo, J.; Alvarez-Muñiz, J.; Alves Batista, R.; Ambrosio, M.; Aminaei, A.

    2016-01-01

    To exploit the full potential of radio measurements of cosmic-ray air showers at MHz frequencies, a detector timing synchronization within 1 ns is needed. Large distributed radio detector arrays such as the Auger Engineering Radio Array (AERA) rely on timing via the Global Positioning System (GPS) for the synchronization of individual detector station clocks. Unfortunately, GPS timing is expected to have an accuracy no better than about 5 ns. In practice, in particular in AERA, the GPS clocks exhibit drifts on the order of tens of ns. We developed a technique to correct for the GPS drifts, and an independent method is used to cross-check that indeed we reach a nanosecond-scale timing accuracy by this correction. First, we operate a ''beacon transmitter'' which emits defined sine waves detected by AERA antennas recorded within the physics data. The relative phasing of these sine waves can be used to correct for GPS clock drifts. In addition to this, we observe radio pulses emitted by commercial airplanes, the position of which we determine in real time from Automatic Dependent Surveillance Broadcasts intercepted with a software-defined radio. From the known source location and the measured arrival times of the pulses we determine relative timing offsets between radio detector stations. We demonstrate with a combined analysis that the two methods give a consistent timing calibration with an accuracy of 2 ns or better. Consequently, the beacon method alone can be used in the future to continuously determine and correct for GPS clock drifts in each individual event measured by AERA

  14. Bulk monitoring of soil for low level transuranic contamination

    International Nuclear Information System (INIS)

    Mandler, J.W.; Randolph, P.D.

    1976-01-01

    A system using γ-ray analysis was developed to survey the soil surrounding retrieval barrels for liquid radioactive waste containing 239 Pu and 241 Am. The performance of scintillation detectors of various sizes for monitoring soil samples was evaluated

  15. Prospects of Appliance-Level Load Monitoring in Off-the-Shelf Energy Monitors: A Technical Review

    Directory of Open Access Journals (Sweden)

    Anwar Ul Haq

    2018-01-01

    Full Text Available The smart grid initiative has encouraged utility companies worldwide to roll-out new and smarter versions of energy meters. Before an extensive roll-out, which is both labor-intensive and incurs high capital costs, consumers need to be incentivised to reap the long-term benefits of such smart meters. Off-the-shelf energy monitors (e-monitors can provide consumers with an insight into such potential benefits. As e-monitors are owned by the consumer, the consumer has greater control over the data, which significantly reduces the privacy and data confidentiality concerns. Because only limited online technical information is available about e-monitors, we evaluate several existing e-monitors using an online technical survey directly from the vendors. Besides automated e-monitoring, the use of different off-the-shelf e-monitors can also help to demonstrate state-of-the-art techniques such as non-intrusive load monitoring (NILM, data analytics, and the predictive maintenance of appliances. Our survey indicates a trend towards the incorporation of such state-of-the-art capabilities, particularly the appliance-level e-monitoring and load disaggregation. We have also discussed some essential requirements to implement load disaggregation in the next generation e-monitors. In future, these intelligent e-monitoring techniques will encourage effective consumer participation in the demand-side management (DSM programs.

  16. On-line monitoring of low-level plutonium concentrations

    International Nuclear Information System (INIS)

    Hofstetter, K.J.; Huff, G.A.; Rebagay, T.V.

    1979-10-01

    An on-line monitor has been developed to assay plutonium in nitric acid solutions. The performance of the monitor has been assessed by a laboratory experimentation program using solutions with plutonium concentrations from 0.1 to 10 g/l. These conditions are typical of the plutonium solutions in an input stream to a plutonium-purification cycle in a reprocessing plant following uranium/plutonium partitioning. The monitoring system can be fully automated and shows great promise for detecting and quantifying plutonium in situ, thus minimizing the reliance on traditional sampling and laboratory-analysis techniques. The total concentration and isotopic abundance of plutonium are determined by measuring the absolute intensities of the low-energy gamma rays characteristics of 238 Pu, 239 Pu, and 240 Pu nuclides by direct gamma-ray spectroscopy and computer analysis of the spectral data. The addition of a monitoring system of this type to the input stream of a plutonium-purification cycle along with other suitable monitors on the waste streams and on the product stream provides the basis for a near real-time materials control and inventory system. Results of the laboratory-evaluation program employing plutonium in solutions with isotopic compositions typical of those involved in processing light water reactor fuels are presented. The detailed design of a monitoring cell and detection system is given. The precision and accuracy of the results relative to those measured by mass spectrometry and controlled potential coulometry are also summarized

  17. Contaminants and nutrients in variable sea areas (Canvas). Application of automatic monitoring stations in the German marine environment

    International Nuclear Information System (INIS)

    Nies, H.; Bruegge, B.; Sterzenbach, D.; Knauth, H.D.; Schroeder, F.

    1999-01-01

    Permanent observation of parameters at sea stations can only be obtained by automatic sampling. The MERMAID technique developed in former projects provides a possibility to run automatic stations within the German MARNET measuring stations to obtain data on nutrients concentration on line and to collect organic micropollutants and the radionuclide 137 Cs by solid phase extraction from seawater and subsequent analysis in the laboratory. The BSH MARNET consists of ten stations located in the German Bight sector of the North Sea and the western Baltic. First results from the time series of nutrient and organic micropollutant concentrations has been presented

  18. Forsmark site investigation. Monitoring of brook water levels, electrical conductivities, temperatures and discharges January-December 2010

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, Per-Olof (Artesia Grundvattenkonsult (Sweden)); Juston, John (Juston Konsult (Sweden))

    2011-06-15

    This document reports the monitoring of water levels, electrical conductivities, temperatures and discharges at four brook discharge gauging stations, and the monitoring of water electrical conductivity at the outlet of Lake Bolundsfjaerden in the Forsmark area. The report presents data from 1 January through 31 December 2010 and is a continuation of reporting from Johansson and Juston (2007, 2009, 2011), which covered the periods from 1 April 2004 through 31 March 2007, 1 April 2007 through 31 December 2008, and 1 January through 31 December 2009, respectively. Long-throated flumes equipped with automatically recording devices were used for the discharge measurements. Every c. 14 days the water depths at the upstream edge of the flumes were measured manually by a ruler as a check. Electrical conductivity and temperature were automatically recorded and these parameters were also measured manually every c. 14 days with the site investigation field devices. SKB's Hydro Monitoring System (HMS) was used to collect and store all data. From HMS quality assured data were transferred to SKB's primary database Sicada. Measurements of levels, electrical conductivities and temperatures were made every 10 minutes (every 30 minutes for electrical conductivity at the outlet of Lake Bolundsfjaerden). For the calculation of discharge, quality assured water level data from the flumes were used. The calculation procedure included consolidation of the time series to hourly averages, screening of data for removal of short-term spikes, noise and other data that were judged erroneous. After the calculations were performed, the results were delivered to Sicada. The amplitudes of water level variations during this reporting period were 0.41-0.55 m and the mean electrical conductivities varied between 23 and 39 mS/m at the four discharge stations. However, due to mal-function of measuring devices for electrical conductivity, data were missing for relatively long time periods. Due

  19. Effect of Different Levels of Methionine on Performance of Khorasan Station Native Hens at Different Production Stages

    Directory of Open Access Journals (Sweden)

    A Hesabi Nameghi

    2012-02-01

    To investigate the effects of different levels of the amino acid methionine(Met on performance of birds native Khorasan province, an experiment using 300 pieces of chicken native Station Native chickens Khorasan in the form of designs completely randomized design with 6 treatments, 5 replicates and 10 chickens in each replicate from age 26 till 52 weeks implemented. 6 treatments follows that the first treatment of Met to 0.22% received the basal diet( control and other treatments to Met level of 0.1% in each treatment and were increased so that the six birds different Met (0.22,0.32,0.42,0.52,0.62 and 0.72 percent received. The results showed that the Met levels increase the total weight of eggs produced in the experimental period (P

  20. Monitoring operational conditions of vehicle tyre pressure levels and ...

    African Journals Online (AJOL)

    Compliance with vehicle tyre inflation pressure and tread depth standard specifications and legal requirements were monitored by survey study in Kumasi Metropolis, Ghana. The survey covered 400 vehicles, comprising cars (28 %), medium buses (25 %), large capacity buses (15 %) and trucks (32 %). There were wide ...

  1. External gamma radiation monitoring in the environs of Kaiga Generating Station (KGS), using thermoluminescent dosimeters, during the period 1989-2003

    International Nuclear Information System (INIS)

    Basu, A.S.; Chougaonkar, M.P.; Mayya, Y.S.; Puranik, V.D.; Reji, T.K.; Ravi, P.M.; Hegde, A.G.

    2005-05-01

    This publication reports the results of external gamma radiation monitoring using Thermoluminescent Dosimeters (TLDs), in the environs of Kaiga Generating Station (KGS) during its preoperational survey between October 1989 and June 1998. The report also presents quarterly and annual values of air dose during the operational phase of the station between July 1998 and Dec. 2003 around the environmcnt of KGS. The results of TLD analysis, during the period October 1989-June 1998, indicate that the average annual air dose for the locations monitored, was 502± 91 μGy/a. The general background of the environs around Kaiga during the operational period, i.e. July 1998 and Dec. 2003, between 2.3 km. to 32km. has been found to be 509±74 μGy/a. The report discusses the methodology and different analyses carried out. (author)

  2. Estimating Ground-Level PM2.5 by Fusing Satellite and Station Observations: A Geo-Intelligent Deep Learning Approach

    Science.gov (United States)

    Li, Tongwen; Shen, Huanfeng; Yuan, Qiangqiang; Zhang, Xuechen; Zhang, Liangpei

    2017-12-01

    Fusing satellite observations and station measurements to estimate ground-level PM2.5 is promising for monitoring PM2.5 pollution. A geo-intelligent approach, which incorporates geographical correlation into an intelligent deep learning architecture, is developed to estimate PM2.5. Specifically, it considers geographical distance and spatiotemporally correlated PM2.5 in a deep belief network (denoted as Geoi-DBN). Geoi-DBN can capture the essential features associated with PM2.5 from latent factors. It was trained and tested with data from China in 2015. The results show that Geoi-DBN performs significantly better than the traditional neural network. The out-of-sample cross-validation R2 increases from 0.42 to 0.88, and RMSE decreases from 29.96 to 13.03 μg/m3. On the basis of the derived PM2.5 distribution, it is predicted that over 80% of the Chinese population live in areas with an annual mean PM2.5 of greater than 35 μg/m3. This study provides a new perspective for air pollution monitoring in large geographic regions.

  3. The NRPI multi-purpose on-line monitoring station for measurement of natural radioactivity in the ambient atmosphere and in the soil

    International Nuclear Information System (INIS)

    Jilek, K.; Slezakova, M.; Fronka, A.; Prokop, T.; Neubauer, L.

    2017-01-01

    During years 2010 12 an automated, on-line and wireless outdoor measurement station of atmospheric radon, gamma dose rate and meteorological parameters was realised at the National Radiation Protection Institute (NRPI) in Prague. At the turn of the year 2013 an expansion of the existing station was completed. Under the project funded by the Czech Technological Agency a new updated station was established, additionally equipped with modules for measurement of atmospheric radon/thoron short-lived decay products, radon in water and soil and radon exhalation rate from soil. After the introduction of the station updated key detection parameters and benefits, its use for atmospheric modelling and monitoring is demonstrated. There are summarised results from the 3-year measurement period in the NRPI outdoor area in Prague and from simultaneous annual measurement performed by another similar station located near uranium mud fields in DIAMO, state enterprise, Straz pod Ralskem. Observed seasonal and diurnal variations of atmospheric radon concentrations and variability of the equilibrium factor, F, are illustrated and compared. (authors)

  4. Technical evaluation report on the monitoring of electric power to the reactor-protection system for the Pilgrim Nuclear Power Station

    International Nuclear Information System (INIS)

    Selan, J.C.

    1982-01-01

    This report documents the technical evaluation of the monitoring of electric power to the reactor protection system (RPS) at the Pilgrim Nuclear Power Station. The evaluation is to determine if the proposed design modification will protect the RPS from abnormal voltage and frequency conditions which could be supplied from the power supplies and will meet certain requirements set forth by the Nuclear Regulatory Commission. The proposed design modifications will protect the RPS from sustained abnormal voltage and frequency conditions from the supplying sources

  5. Assessment of Technology Readiness Level of a Carbon Dioxide Reduction Assembly (CRA) for use on International Space Station

    Science.gov (United States)

    Murdoch, Karen; Smith, Fred; Perry, Jay; Green, Steve

    2004-01-01

    When technologies are traded for incorporation into vehicle systems to support a specific mission scenario, they are often assessed in terms of Technology Readiness Level (TRL). TRL is based on three major categories of Core Technology Components, Ancillary Hardware and System Maturity, and Control and Control Integration. This paper describes the Technology Readiness Level assessment of the Carbon Dioxide Reduction Assembly (CRA) for use on the International Space Station. A team comprising of the NASA Johnson Space Center, Marshall Space Flight Center, Southwest Research Institute and Hamilton Sundstrand Space Systems International have been working on various aspects of the CRA to bring its TRL from 4/5 up to 6. This paper describes the work currently being done in the three major categories. Specific details are given on technology development of the Core Technology Components including the reactor, phase separator and CO2 compressor.

  6. Guidelines for Learning Stations.

    Science.gov (United States)

    Fehrle, Carl C.; Schulz, Jolene

    Guidelines for designing and planning learning stations for pupils at the elementary grade level include suggestions on how to develop a station that will be successful in meeting the learners' needs. Instructions for the use of tapes at a station and matching pupils with stations are given, as are guidelines on classroom arrangement and record…

  7. Evaluation of the electromagnetic field level emitted by medium frequency AM broadcast stations

    International Nuclear Information System (INIS)

    Licitra, G.; Bambini, S.; Barellini, A.; Monorchio, A.; Rogovich, A.

    2004-01-01

    In order to estimate the level of the electromagnetic field produced by telecommunication systems, different computational techniques can be employed whose complexity depends on the accuracy of the final results. In this paper, we present the validation of a code based on the method of moments that allows us to analyse the electromagnetic field emitted by radio-communication systems operating at medium frequencies. The method is able to provide an accurate estimate of the levels of electromagnetic field produced by this type of device and, consequently, it can be used as a method for verifying the compliance of the system with the safe exposure level regulations and population protection laws. Some numerical and experimental results are shown relevant to an amplitude modulated (AM) radio transmitter, together with the results of a forthcoming system that will be operative in the near future. (authors)

  8. Support of Gulf of Mexico Hydrate Research Consortium: Activities of Support Establishment of a Sea Floor Monitoring Station Project

    Energy Technology Data Exchange (ETDEWEB)

    J. Robert Woolsey; Thomas McGee; Carol Lutken

    2008-05-31

    The Gulf of Mexico Hydrates Research Consortium (GOM-HRC) was established in 1999 to assemble leaders in gas hydrates research that shared the need for a way to conduct investigations of gas hydrates and their stability zone in the Gulf of Mexico in situ on a more-or-less continuous basis. The primary objective of the group is to design and emplace a remote monitoring station or sea floor observatory (SFO) on the sea floor in the northern Gulf of Mexico, in an area where gas hydrates are known to be present at, or just below, the sea floor and to discover the configuration and composition of the subsurface pathways or 'plumbing' through which fluids migrate into and out of the hydrate stability zone (HSZ) to the sediment-water interface. Monitoring changes in this zone and linking them to coincident and perhaps consequent events at the seafloor and within the water column is the eventual goal of the Consortium. This mission includes investigations of the physical, chemical and biological components of the gas hydrate stability zone - the sea-floor/sediment-water interface, the near-sea-floor water column, and the shallow subsurface sediments. The eventual goal is to monitor changes in the hydrate stability zone over time. Establishment of the Consortium succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among those involved in gas hydrates research. Complementary expertise, both scientific and technical, has been assembled to promote innovative methods and construct necessary instrumentation. Following extensive investigation into candidate sites, Mississippi Canyon 118 (MC118) was chosen by consensus of the Consortium at their fall, 2004, meeting as the site most likely to satisfy all criteria established by the group. Much of the preliminary work preceding the establishment of the site - sensor development and testing, geophysical surveys, and laboratory studies - has been reported in

  9. National Coral Reef Monitoring Program: Benthic Images Collected from Climate Stations across the Hawaiian Archipelago since 2013

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Photoquadrat benthic images were collected at NCRMP climate stations and permanent sites identified by the Ocean and Climate Change team across the Hawaiian...

  10. National Coral Reef Monitoring Program: Benthic Images Collected from Climate Stations across the Mariana Archipelago in 2014

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Photoquadrat benthic images were collected at NCRMP climate stations and permanent sites identified by the Ocean and Climate Change team across the Mariana...

  11. National Coral Reef Monitoring Program: Benthic Images Collected from Climate Stations across the Mariana Archipelago in 2014 (NCEI Accession 0157759)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Photoquadrat benthic images were collected at NCRMP climate stations and permanent sites identified by the Ocean and Climate Change team across the Mariana...

  12. The new Mediterranean background monitoring station of Ersa, Cape Corsica: A long term Observatory component of the Chemistry-Aerosol Mediterranean Experiment (ChArMEx)

    Science.gov (United States)

    Dulac, Francois

    2013-04-01

    The Chemistry-Aerosol Mediterranean Experiment (ChArMEx, http://charmex.lsce.ipsl.fr/) is a French initiative supported by the MISTRALS program (Mediterranean Integrated Studies at Regional And Locals Scales, http://www.mistrals-home.org). It aims at a scientific assessment of the present and future state of the atmospheric environment in the Mediterranean Basin, and of its impacts on the regional climate, air quality, and marine biogeochemistry. The major stake is an understanding of the future of the Mediterranean region in a context of strong regional anthropogenic and climatic pressures. The target of ChArMEx is short-lived particulate and gaseous tropospheric trace species which are the cause of poor air quality events, have two-way interactions with climate, or impact the marine biogeochemistry. In order to fulfill these objectives, important efforts have been put in 2012 in order to implement the infrastructure and instrumentation for a fully equipped background monitoring station at Ersa, Cape Corsica, a key location at the crossroads of dusty southerly air masses and polluted outflows from the European continent. The observations at this station began in June 2012 (in the context of the EMEP / ACTRIS / PEGASOS / ChArMEx campaigns). A broad spectrum of aerosol properties is also measured at the station, from the chemical composition (off-line daily filter sampling in PM2.5/PM10, on-line Aerosol Chemical Speciation Monitor), ground optical properties (extinction/absorption/light scattering coeff. with 1-? CAPS PMex monitor, 7-? Aethalometer, 3-? Nephelometer), integrated and vertically resolved optical properties (4-? Cimel sunphotometer and LIDAR, respective), size distribution properties (N-AIS, SMPS, APS, and OPS instruments), mass (PM1/PM10 by TEOM/TEOM-FDMS), hygroscopicity (CCN), as well as total insoluble deposition. So far, real-time measurement of reactive gases (O3, CO, NO, NO2), and off-line VOC measurements (cylinders, cartridges) are also

  13. Coastal meteorological and water temperature data from National Water Level Observation Network (NWLON) and Physical Oceanographic Real-Time System (PORTS) stations of the NOAA Center for Operational Oceanographic Products and Services (CO-OPS)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The National Water Level Observation Network (NWLON) is a network of long-term water level stations operated and maintained by CO-OPS. NWLON stations are located on...

  14. Conceptual design of intravenous fluids level monitoring system - a review

    Science.gov (United States)

    Verma, Prikshit; Padmani, Aniket; Boopathi, M.

    2017-11-01

    In today’s world of automation, there are advancements going on in all the fields. Each work is being automated day by day. However, if we see our current medical care system, some areas require manual caretaker and are loaded with heavy jobs, which consumes a lot of time. Nevertheless, since the work is related to human health, it should be properly done and that too with accuracy. An example of such a particular work is injecting saline or Intravenous (IV) fluids in a patient. The monitoring of such fluids needs utter attention as if the bottle of the fluid is not changed on time, it may lead to various problems for the patients like backflow of blood, blood loss etc. Various researches have been performed to overcome such critical situation. Different monitoring and alerting techniques are described in different researches. So, in our study, we will go through the researches done in this particular field and will see how different ideas are implemented.

  15. Forest Focus Monitoring Database System - Technical Report 2003 Level II Data

    OpenAIRE

    HIEDERER ROLAND; DURRANT TRACY; GRANKE O.; LAMBOTTE Michel; LORENZ M.; MIGNON B.; OEHMICHEN K.

    2007-01-01

    Forest Focus (Regulation (EC) No 2152/2003) is a Community scheme for harmonized, broad-based, comprehensive and long-term monitoring of European forest ecosystems. Under this scheme the monitoring of air pollution effects on forests is carried out by participating countries on the basis of the systematic network of observation points (Level I) and of the network of observation plots for intensive and continuous monitoring (Level II). According to Article 15(1) of the Forest Focus Regulat...

  16. Forest Focus Monitoring Database System - Technical Report 2006 Level II Data

    OpenAIRE

    HIEDERER Roland; DURRANT Tracy; GRANKE Oliver; LAMBOTTE Michel; LORENZ Martin; MIGNON Bertrand

    2008-01-01

    Forest Focus (Regulation (EC) No 2152/2003) is a Community scheme for harmonized, broadbased, comprehensive and long-term monitoring of European forest ecosystems. Under this scheme the monitoring of air pollution effects on forests is carried out by participating countries on the basis of the systematic network of observation points (Level I) and of the network of observation plots for intensive and continuous monitoring (Level II). According to Article 15(1) of the Forest Focus Regulatio...

  17. Low sidelobe level low-cost earth station antennas for the 12 GHz broadcasting satellite service

    Science.gov (United States)

    Collin, R. E.; Gabel, L. R.

    1979-01-01

    An experimental investigation of the performance of 1.22 m and 1.83 m diameter paraboloid antennas with an f/D ratio of 0.38 and using a feed developed by Kumar is reported. It is found that sidelobes below 30 dB can be obtained only if the paraboloids are relatively free of surface errors. A theoretical analysis of clam shell distortion shows that this is a limiting factor in achieving low sidelobe levels with many commercially available low cost paraboloids. The use of absorbing pads and small reflecting plates for sidelobe reduction is also considered.

  18. A field method for monitoring thoron-daughter working level

    International Nuclear Information System (INIS)

    Khan, A.H.; Dhandayatham, R.; Raghavayya, M.; Nambiar, P.P.V.J.

    1975-01-01

    The concept of working level, generally used for radon daughters, has been extended to the daughter products of thoron. Accordingly, thorondaughter working level (TWL) has been defined as the alpha energy released from the ultimate decay of 100 pCi/1 each of the short-lived decay products of thoron. In order to facilitate the evaluation of inhalation hazard in thorium handling areas, a simple field method has been suggested to measure the thoron-daughter working level. A comparison of the potential alpha energies from radon-daughters and that from thoron-daughter is included. (K.B.)

  19. Planning Workshop on Local Level Poverty Monitoring System

    International Development Research Centre (IDRC) Digital Library (Canada)

    Md. Abdul Quader - Ranjan Kumar Guha

    decision making and incorporate these in preparing the development plans and programmes of the ... and highlight the usefulness of the information in local level planning. The aim ..... proper accounts of the cooperatives for its sustainability.

  20. Practical experience with own monitoring of clay sealings on dumps for brown coal-fired power station residues. Erfahrungen mit der Eigenueberwachung an Tonabdichtungen der Deponien fuer Braunkohlenkraftwerksrueckstaende

    Energy Technology Data Exchange (ETDEWEB)

    Winter, K

    1989-07-01

    In order to dispose of power station residues Rheinbraun erects dumps which are encased by a clay sealing. For the Fortuna dump 10 hectares sealing area, with a permeability that is lower than the required limit value of k = 5x10{sup -10} m/s, have so far been constructed. The quality of the sealing is monitored and ensured by graded checking. The practical experience gained so far with own monitoring (selection of material, supervision of construction site and own checking) on the finished clay sealings is discussed in the present paper. The system of testing the sealings has proved very satisfactory. The results of the tests carried out in the course of own monitoring show that processing work in the laboratory can be reduced by systematic selection of material and intensive expert supervision of the construction site. (orig.).

  1. Prototype architecture for a VLSI level zero processing system. [Space Station Freedom

    Science.gov (United States)

    Shi, Jianfei; Grebowsky, Gerald J.; Horner, Ward P.; Chesney, James R.

    1989-01-01

    The prototype architecture and implementation of a high-speed level zero processing (LZP) system are discussed. Due to the new processing algorithm and VLSI technology, the prototype LZP system features compact size, low cost, high processing throughput, and easy maintainability and increased reliability. Though extensive control functions have been done by hardware, the programmability of processing tasks makes it possible to adapt the system to different data formats and processing requirements. It is noted that the LZP system can handle up to 8 virtual channels and 24 sources with combined data volume of 15 Gbytes per orbit. For greater demands, multiple LZP systems can be configured in parallel, each called a processing channel and assigned a subset of virtual channels. The telemetry data stream will be steered into different processing channels in accordance with their virtual channel IDs. This super system can cope with a virtually unlimited number of virtual channels and sources. In the near future, it is expected that new disk farms with data rate exceeding 150 Mbps will be available from commercial vendors due to the advance in disk drive technology.

  2. Continuous liquid level monitoring sensor system using fiber Bragg grating

    Science.gov (United States)

    Sengupta, Dipankar; Kishore, Putha

    2014-01-01

    The design and packaging of simple, small, and low cost sensor heads, used for continuous liquid level measurement using uniformly thinned (etched) optical fiber Bragg grating (FBG) are proposed. The sensor system consists of only an FBG and a simple detection system. The sensitivity of sensor is found to be 23 pm/cm of water column pressure. A linear optical fiber edge filter is designed and developed for the conversion of Bragg wavelength shift to its equivalent intensity. The result shows that relative power measured by a photo detector is linearly proportional to the liquid level. The obtained sensitivity of the sensor is nearly -15 mV/cm.

  3. Monitoring Blood Sugar: The Importance of Checking Blood Sugar Levels

    Science.gov (United States)

    ... closer to the levels seen in people without diabetes) your child's HbA1c, the better controlled the blood sugars have ... Diabetes Hypoglycemia Diabetes Control: Why It's Important Your Child's Diabetes Health Care Team Helping Kids Deal With Injections ...

  4. Rule-based emergency action level monitor prototype

    International Nuclear Information System (INIS)

    Touchton, R.A.; Gunter, A.D.; Cain, D.

    1985-01-01

    In late 1983, the Electric Power Research Institute (EPRI) began a program to encourage and stimulate the development of artificial intelligence (AI) applications for the nuclear industry. Development of a rule-based emergency action level classification system prototype is discussed. The paper describes both the full prototype currently under development and the completed, simplified prototype

  5. Radio Frequency Based Water Level Monitor and Controller for ...

    African Journals Online (AJOL)

    Similarly, the control unit of the prototype performs automatic switching control of on and off on a single phase centrifugal water pump, 220volts, 0.5hp motor via a motor driver circuit (relay). It also incorporates a buzzer that beeps briefly when water level hits 100%, thus causing the pump to be switched off but when water ...

  6. The Relationship with Self Esteem Between Self Monitoring Levels of Sub Elite In - Door Soccer Players

    Directory of Open Access Journals (Sweden)

    Mehmet Behzat T U R A N

    2015-07-01

    Full Text Available The aim of this study was to investigate the relationship with self - esteem between self monitoring levels of sub - elite in - door soccer players. For this aim, 86 male and 91 female athletes at the ages of 18 – 28 years were participated in this study voluntarily. The participants were studying at 7 different universities that join ed the in - door soccer championship of Turkish University Sport Federati on. The Socio - demographic data form, Self - monitoring Scale , and Coopersmith Self - Esteem Inventory were performed by the participants. The d ata was analyzed by using IBM SPSS (version 20.0. The Spearman Correlation parameter calculated in order to comment the relationship with data, Multiple regret ion analysis were performed for the predictive power of self - esteem for self monitoring levels of the participants. According to the analysis, a negative relationship was found among self - esteem, self - monitoring total score , and extraversion levels . A nd it was found that self - esteem levels predictived self monitoring levels substantially. It was found that the s elf - monitoring and extraversion affected self - esteem negatively, it was thought that highly self - esteem ed athletes have a tendency to see themselves as superior than the other athletes, ignore the extraneous criticism. No matter what self - esteem levels is that extraversion and acting altitute (attitude ? has not change. Consequently, self - esteem has revers e relationship with self - monitoring properties since trainers and teachers both is raised self - esteem and is helped self - monitoring themselves.

  7. Ozone Laminae and Their Entrainment Into a Valley Boundary Layer, as Observed From a Mountaintop Monitoring Station, Ozonesondes, and Aircraft Over California's San Joaquin Valley

    Science.gov (United States)

    Faloona, I. C.; Conley, S. A.; Caputi, D.; Trousdell, J.; Chiao, S.; Eiserloh, A. J., Jr.; Clark, J.; Iraci, L. T.; Yates, E. L.; Marrero, J. E.; Ryoo, J. M.; McNamara, M. E.

    2016-12-01

    The San Joaquin Valley of California is wide ( 75 km) and long ( 400 km), and is situated under strong atmospheric subsidence due, in part, to the proximity of the midlatitude anticyclone of the Pacific High. The capping effect of this subsidence is especially prominent during the warm season when ground level ozone is a serious air quality concern across the region. While relatively clean marine boundary layer air is primarily funneled into the valley below the strong subsidence inversion at significant gaps in the upwind Coast Range mountains, airflow aloft also spills over these barriers and mixes into the valley from above. Because this transmountain flow occurs under the influence of synoptic subsidence it tends to present discrete, laminar sheets of differing air composition above the valley boundary layer. Meanwhile, although the boundary layers tend to remain shallow due to the prevailing subsidence, orographic and anabatic venting of valley boundary layer air around the basin whips up a complex admixture of regional air masses into a "buffer layer" just above the boundary layer (zi) and below the lower free troposphere. We present scalar data of widely varying lifetimes including ozone, methane, NOx, and thermodynamic observations from upwind and within the San Joaquin Valley to better explain this layering and its subsequent erosion into the valley boundary layer via entrainment. Data collected at a mountaintop monitoring station on Chews Ridge in the Coast Range, by coastal ozonesondes, and aircraft are analyzed to document the dynamic layering processes around the complex terrain surrounding the valley. Particular emphasis will be made on observational methods whereby distal ozone can be distinguished from the regional ozone to better understand the influence of exogenous sources on air quality in the valley.

  8. Biological monitors for low levels of ionising radiation

    International Nuclear Information System (INIS)

    Mohankumar, M.N.; Jeevanram, R.K.

    1995-01-01

    The biological effects of high doses of ionising radiation are well understood and the methods of measurement of these doses well established. However the effects due to extremely low doses remain by and large uncertain. This is because of the fact that at such low doses no gross symptoms are seen. In fact, at these levels the occurrence of double strand breaks leading to the formation of chromosomal aberrations like dicentrics is rare and chances of mutation due to base damage are negligible. Hence neither chromosomal aberration studies nor mutational assays are useful for detecting doses of the order of a few milligray. Results of exhaustive work done by various laboratories indicate that below 20 mGy the chromosomal aberration technique based on scoring of dicentrics cannot distinguish between a linear or a threshold model. However indirect methods like unscheduled DNA synthesis (UDS) and sister chromatid exchanges (SCEs) appear to be promising for the detection of radiation exposures due to low levels of radiation. This report reviews the available literature on the biological effects of low levels of ionising radiation and highlights the merits and demerits of the various methods employed in the measurement of UDS and SCE. The phenomenon of radio-adaptive response (RAR) and its relation to DNA repair is also discussed. (author)

  9. Biological monitors for low levels of ionising radiation

    Energy Technology Data Exchange (ETDEWEB)

    Mohankumar, M N; Jeevanram, R K [Safety Research and Health Physics Group, Indira Gandhi Centre for Atomic Research, Kalpakkam (India)

    1996-12-31

    The biological effects of high doses of ionising radiation are well understood and the methods of measurement of these doses well established. However the effects due to extremely low doses remain by and large uncertain. This is because of the fact that at such low doses no gross symptoms are seen. In fact, at these levels the occurrence of double strand breaks leading to the formation of chromosomal aberrations like dicentrics is rare and chances of mutation due to base damage are negligible. Hence neither chromosomal aberration studies nor mutational assays are useful for detecting doses of the order of a few milligray. Results of exhaustive work done by various laboratories indicate that below 20 mGy the chromosomal aberration technique based on scoring of dicentrics cannot distinguish between a linear or a threshold model. However indirect methods like unscheduled DNA synthesis (UDS) and sister chromatid exchanges (SCEs) appear to be promising for the detection of radiation exposures due to low levels of radiation. This report reviews the available literature on the biological effects of low levels of ionising radiation and highlights the merits and demerits of the various methods employed in the measurement of UDS and SCE. The phenomenon of radio-adaptive response (RAR) and its relation to DNA repair is also discussed. (author). 98 refs., 11 figs., 4 tabs.

  10. DOSIS & DOSIS 3D: long-term dose monitoring onboard the Columbus Laboratory of the International Space Station (ISS)

    Czech Academy of Sciences Publication Activity Database

    Berger, T.; Przybyla, B.; Matthia, D.; Reitz, G.; Burmeister, S.; Labrenz, J.; Bilski, P.; Horwacik, T.; Twardak, A.; Hajek, M.; Fugger, M.; Hofstatter, C.; Sihver, L.; Palfalvi, J. K.; Szabó, J.; Stradi, A.; Ambrožová, Iva; Kubančák, Ján; Brabcová, Kateřina; Vanhavere, F.; Cauwels, V.; Van Hoey, O.; Schoonjans, W.; Parisi, A.; Gaza, R.; Semones, E.; Yukihara, E.; Benton, E.; Doull, B. A.; Uchihori, Y.; Kodaira, S.; Kitamura, H.; Böhme, M.

    2016-01-01

    Roč. 6, NOV (2016), č. článku A39. ISSN 2115-7251 R&D Projects: GA ČR GJ15-16622Y Institutional support: RVO:61389005 Keywords : International Space Station * Columbus * space radiation * DOSIS * DOSIS 3D Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 2.446, year: 2016

  11. Low-level radioactive waste from nuclear power generating stations: Characterization, classification and assessment of activated metals and waste streams

    International Nuclear Information System (INIS)

    Thomas, V.W.; Robertson, D.E.; Thomas, C.W.

    1993-02-01

    Since the enactment of 10 CFR Part 61, additional difficult-to-measure long-lived radionuclides, not specified in Tables 1 2 of Part 61, have been identified (e.g., 108m Ag, 93 Mo, 36 Cl, 10 Be, 113m Cd, 121m Sn, 126 Sn, 93m Nb) that may be of concern in certain types of waste. These nuclides are primarily associated with activated metal and perhaps other nuclear power low-level waste (LLW) being sent to disposal facilities. The concentration of a radionuclide in waste materials is normally determined by direct measurement or by indirect calculational methods, such as using a scaling factor to relate inferred concentration of a difficult-to-measure radionuclide to another that is easily measured. The total disposal site inventory of certain difficult-to-measure radionuclides (e.g., 14 C, 129 I, and 99 Tc) often control the total quantities of radioactive waste permitted in LLW burial facilities. Overly conservative scaling factors based on lower limits of detection (LLD), often used in the nuclear power industry to estimate these controlling nuclides, could lead to premature closure of a disposal facility. Samples of LLW (Class B and C activated metals [AM] and other waste streams) are being collected from operating nuclear power stations and analyzed for radionuclides covered in 10 CFR Part 61 and the additional difficult-to-measure radionuclides. This analysis will enhance the NRC's understanding of the distribution and projected quantities of radionuclides within AM and LLW streams from commercial nuclear power stations. This research will also provide radiological characterization of AM specimens for others to use in leach-rate and lysimeter experiments to determine nuclide releases and subsequent movement in natural soil environments

  12. Use of a microprocessor in a remote working level monitor

    International Nuclear Information System (INIS)

    Keefe, D.J.; McDowell, W.P.; Groer, P.G.

    1976-01-01

    The instrument described measures the short-lived 222 Rn-daughter concentrations and the Working Level (WL) in sealed ''hot chambers'' located in uranium mines. Radiation-induced pulses from two separate sensors are transmitted through 500 ft. cables to a microprocessor, which processes the pulses and controls the operation of the system. A read-only memory stores a fixed program which is used to calculate the desired concentrations. The results are printed as pCi/l (Rn-daughter concentrations) and WL

  13. Monitoring levels of deoxynivalenol in wheat flour of Brazilian varieties

    Directory of Open Access Journals (Sweden)

    Cristiano L Silva

    2015-03-01

    Full Text Available Deoxynivalenol (DON is a mycotoxin produced by Fusarium graminearum and its intake represents a severe risk to human and animal health. The objective of this study was to evaluate levels of DON in wheat (Triticum aestivum L. flour from two representative locations of south Brazil. Experiments were carried out in Pato Branco (Paraná and Coxilha (Rio Grande do Sul in a randomized complete block design with three replicates. Levels of DON were measured by high-performance liquid chromatography coupled with mass spectrometry (HPLC-MS/MS. This mycotoxin was detected in 97% of samples, ranging from 200 to 4140 u,g kg-1. Only 17% of samples presented DON beyond of the maximum allowed by the Brazilian Health Surveillance Agency up to the year 2012; even though, Fusarium head blight (FHB epidemics were slight low in the growing season that the study was performed. According to our knowledge, this is the first report showing genetic variability of Brazilian cultivars to DON contamination and some genotypes have potential to be exploited as a source of low accumulation of this toxin.

  14. Natural Radioactivity Accumulated in the Arctic from Long-range Atmospheric Transport - Observations in Canadian Monitoring Stations

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Jing; Zhang, Weihua [Radiation Protection Bureau, Health Canada, 775 Brookfield Road, Ottawa K1A 1C1 (Canada)

    2014-07-01

    In the environment, the main sources of naturally occurring radionuclides come from radionuclides in the uranium decay series. Activity concentrations of uranium decay series radionuclides may vary considerably from place to place depending on the geological characteristics at the location. Their releases to the atmosphere are mainly through radon ({sup 222}Rn), a radioactive noble gas occurring naturally as an indirect decay product of uranium in soils and rocks. Due to the abundance of uranium, radon continuously emanates from continental land masses. With radon as the main source of naturally occurring radioactivity in the environment, one would think that the Arctic should be an area of low background radiation, because a considerable area of the Arctic is covered by glaciers and permafrost, and radon emanation rate has been reported to be negligible from those glacier and permafrost areas. However, available data have shown the opposite. The elevated level of naturally occurring radioactivity in the Arctic is due to natural sources outside of the Arctic, mainly through long-range atmospheric transport of radon and radon progeny. In some cases, natural radioactivity can accumulate to relatively high levels and become a health concern or a limiting factor of country food consumption. By definition, contaminants are undesirable substances which can cause harm to the environment, the biota, and humans. We can call these naturally accumulating radiological burdens to the Arctic 'natural contaminants' to distinguish them from the traditional meaning of contamination, the 'artificial contaminants' which are attributable to industrial or man-made sources. This paper reviews information available in the literature, analyses long-term atmospheric monitoring data in the Canadian high Arctic, sub-Arctic and mid-latitude sites, and provides discussion on research needed to address questions, such as how heavily the Arctic has been impacted by the

  15. Strategy to design the sea-level monitoring networks for small tsunamigenic oceanic basins: the Western Mediterranean case

    Directory of Open Access Journals (Sweden)

    F. Schindelé

    2008-09-01

    Full Text Available The 26 December 2004 Indian Ocean tsunami triggered a number of international and national initiatives aimed at establishing modern, reliable and robust tsunami warning systems. In addition to the seismic network for initial warning, the main component of the monitoring system is the sea level network. Networks of coastal tide gages and tsunameters are implemented to detect the tsunami after the occurrence of a large earthquake, to confirm or refute the tsunami occurrence. Large oceans tsunami monitoring currently in place in the Pacific and in implementation in the Indian Ocean will be able to detect tsunamis in 1 h. But due to the very short time of waves propagation, in general less than 1 h, a tsunami monitoring system in a smaller basin requires a denser network located close to the seismic zones. A methodology is proposed based on the modeling of tsunami travel time and waveform, and on the estimation of the delay of transmission to design the location and the spacing of the stations. In the case of Western Mediterranean, we demonstrate that a network of around 17 coastal tide gages and 13 tsunameters located at 50 km along the shore is required to detect and measure nearly all tsunamis generated on the Northern coasts of Africa.

  16. Distributed applications monitoring at system and network level

    CERN Document Server

    Aderholz, Michael; Augé, E; Bagliesi, G; Banistoni, G; Barone, L; Boschini, M; Brunengo, A; Bunn, J J; Butler, J; Campanella, M; Capiluppi, P; D'Amato, M; Darneri, M; Di Mattia, A; Dorokhov, A E; Gagliardi, F; Gaines, I; Gasparini, U; Ghiselli, A; Gordon, J; Grandi, C; Gálvez, P; Harris, F; Holtman, K; Karimäki, V; Karita, Y; Klem, J T; Legrand, I; Leltchouk, M; Linglin, D; Lubrano, P; Luminari, L; McArthur, I C; Michelotto, M; Morita, Y; Nazarenko, A; Newman, H; O'Dell, Vivian; O'Neale, S W; Osculati, B; Pepé, M; Perini, L; Pinfold, James L; Pordes, R; Prelz, F; Putzer, A; Resconi, S; Robertson, L; Rolli, S; Sasaki, T; Sato, H; Schaffer, R D; Schalk, T L; Servoli, L; Sgaravatto, M; Shiers, J; Silvestris, L; Siroli, G P; Sliwa, K; Smith, T; Somigliana, R; Stanescu, C; Stockinger, H E; Ugolotti, D; Valente, E; Vistoli, C; Wilkinson, R P; Willers, Ian Malcolm; Williams, D O

    2001-01-01

    Most distributed applications are based on architectural models that do not involve real-time knowledge of network status and of their network usage. Moreover the new "network aware" architectures are still under development and their design is not yet complete. We considered, as a use case, an application using ODBMS (Objectivity /DB) for the distributed analysis of experimental data. The dynamic usage of system and network resources at host and application levels has been measured in different client/server configurations, and on several LAN and WAN layouts. The aim was to study the application efficiency and behavior versus the network characteristics and conditions. The most interesting results of the LAN and WAN tests are described. System bottlenecks and limitations have been identified, and efficient working conditions in the different scenarios have been defined. The behavior observed when moving away from the optimal working conditions is also described.

  17. Technical evaluation report on the monitoring of electric power to the reactor protection system for the Nine Mile Point Nuclear Station, Unit 1 (Docket No. 50-220)

    International Nuclear Information System (INIS)

    Selan, J.C.

    1984-01-01

    This report documents the technical evaluation of the monitoring of electric power to the reactor protection system (RPS) at the Nine Mile Point Nuclear Station, Unit 1. The evaluation is to determine if the proposed design modification will protect the RPS from abnormal voltage and frequency conditions which could be supplied from the power supplies and will meet certain requirements set forth by the Nuclear Regulatory Commission. The proposed design modifications will protect the RPS from sustained abnormal voltage and frequency conditions from the supplying sources

  18. IEEE Std 1205-1993: IEEE guide for assessing, monitoring, and mitigating aging effects on Class 1E equipment used in nuclear power generating stations

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    The guidelines are provided for assessing, monitoring, and mitigating degradation of Class 1E equipment used in nuclear power generating stations due to aging. The methods described can be used to identify the performance capability of Class 1E equipment beyond its qualified life. A discussion of stressors and aging mechanisms is included. If aging considerations have been satisfactorily addressed through other means (e.g., equipment qualification), then use of this guide may not be warranted. For some equipment, only partial application of this guide may be warranted

  19. Minimum deltaV Burn Planning for the International Space Station Using a Hybrid Optimization Technique, Level 1

    Science.gov (United States)

    Brown, Aaron J.

    2015-01-01

    The International Space Station's (ISS) trajectory is coordinated and executed by the Trajectory Operations and Planning (TOPO) group at NASA's Johnson Space Center. TOPO group personnel routinely generate look-ahead trajectories for the ISS that incorporate translation burns needed to maintain its orbit over the next three to twelve months. The burns are modeled as in-plane, horizontal burns, and must meet operational trajectory constraints imposed by both NASA and the Russian Space Agency. In generating these trajectories, TOPO personnel must determine the number of burns to model, each burn's Time of Ignition (TIG), and magnitude (i.e. deltaV) that meet these constraints. The current process for targeting these burns is manually intensive, and does not take advantage of more modern techniques that can reduce the workload needed to find feasible burn solutions, i.e. solutions that simply meet the constraints, or provide optimal burn solutions that minimize the total DeltaV while simultaneously meeting the constraints. A two-level, hybrid optimization technique is proposed to find both feasible and globally optimal burn solutions for ISS trajectory planning. For optimal solutions, the technique breaks the optimization problem into two distinct sub-problems, one for choosing the optimal number of burns and each burn's optimal TIG, and the other for computing the minimum total deltaV burn solution that satisfies the trajectory constraints. Each of the two aforementioned levels uses a different optimization algorithm to solve one of the sub-problems, giving rise to a hybrid technique. Level 2, or the outer level, uses a genetic algorithm to select the number of burns and each burn's TIG. Level 1, or the inner level, uses the burn TIGs from Level 2 in a sequential quadratic programming (SQP) algorithm to compute a minimum total deltaV burn solution subject to the trajectory constraints. The total deltaV from Level 1 is then used as a fitness function by the genetic

  20. Water levels in continuously monitored wells in the Yucca Mountain area, Nevada, 1985--88

    International Nuclear Information System (INIS)

    Luckey, R.R.; Lobmeyer, D.H.; Burkhardt, D.J.

    1993-01-01

    Water levels have been monitored hourly in 15 wells completed in 23 depth intervals in the Yucca Mountain area, Nevada. Water levels were monitored using pressure transducers and were recorded by data loggers. The pressure transducers were periodically calibrated by raising and lowering them in the wells. The water levels were normally measured at approximately the same time that the transducers were calibrated. Where the transducer output appeared reasonable, it was converted to water levels using the calibrations and manual water- level measurements. The amount of transducer output that was converted to water levels ranged from zero for several intervals to about 98 percent for one interval. Fourteen of the wells were completed in Tertiary volcanic rocks and one well was completed in Paleozoic carbonate rocks. Each well monitored from one to four depth intervals. Water-level fluctuation caused by barometric pressure changes and earth tides were observed

  1. Monitoring Water Levels and Discharges Using Radar Altimetry in an Ungauged River Basin: The Case of the Ogooué

    Directory of Open Access Journals (Sweden)

    Sakaros Bogning

    2018-02-01

    Full Text Available Radar altimetry is now commonly used for the monitoring of water levels in large river basins. In this study, an altimetry-based network of virtual stations was defined in the quasi ungauged Ogooué river basin, located in Gabon, Central Africa, using data from seven altimetry missions (Jason-2 and 3, ERS-2, ENVISAT, Cryosat-2, SARAL, Sentinel-3A from 1995 to 2017. The performance of the five latter altimetry missions to retrieve water stages and discharges was assessed through comparisons against gauge station records. All missions exhibited a good agreement with gauge records, but the most recent missions showed an increase of data availability (only 6 virtual stations (VS with ERS-2 compared to 16 VS for ENVISAT and SARAL and accuracy (RMSE lower than 1.05, 0.48 and 0.33 and R² higher than 0.55, 0.83 and 0.91 for ERS-2, ENVISAT and SARAL respectively. The concept of VS is extended to the case of drifting orbits using the data from Cryosat-2 in several close locations. Good agreement was also found with the gauge station in Lambaréné (RMSE = 0.25 m and R2 = 0.96. Very good results were obtained using only one year and a half of Sentinel-3 data (RMSE < 0.41 m and R2 > 0.89. The combination of data from all the radar altimetry missions near Lamabréné resulted in a long-term (May 1995 to August 2017 and significantly improved water-level time series (R² = 0.96 and RMSE = 0.38 m. The increase in data sampling in the river basin leads to a better water level peak to peak characterization and hence to a more accurate annual discharge over the common observation period with only a 1.4 m3·s−1 difference (i.e., 0.03% between the altimetry-based and the in situ mean annual discharge.

  2. [The regional model of three-level system of of medical social monitoring of children and adolescents: the pilot project in the Republic of Tatarstan].

    Science.gov (United States)

    Al'bitskii, V Iu; Ustinova, N V; Farrakhov, A Z; Shavaliev, R F; Kulikov O V; Plaksina, L V

    2014-01-01

    The absence of system of medical social monitoring of children being in difficult life situations is one of main causes of preventable losses of health and life of children and adolescents. The plan of activities of the working group No3 under the Coordination council under the President of the Russian Federation of the national strategy realization of actions in interest of children for 2012-2017 includes a point: "The development and implementation of standard model of medical social monitoring of children and adolescents in the subjects of the Russian Federation". The implementation of this task is assigned to the Department of social pediatrics of The research center of children health of Moscow and the Ministry of Health of the Republic of Tatarstan. The research methods included analysis and generalization of advanced experience of medical social monitoring of children population; expertise technique; modeling. The regional model of three-level system of medical social monitoring of children population is developed and implemented. The model includes level I (consulting rooms of medical social care of children polyclinics, feldsher obstetric stations, first-aid centers), level II--inter-municipal (departments of medical social monitoring in central district hospitals, medical institutions, clinical diagnostic centers) and level III--regional (the Republican center of medical social monitoring of children and adolescents). The immediate tasks necessary for effective functioning of system of medical social monitoring were determined. Within the framework of implementation of the pilot project the legal and normative legislative acts were developed to regulate functioning of regional model of three-level system of medical social care. The other documents necessary for effective functioning of this system were elaborated. The practical significance of this system is in the implementation of effective three-level model of medical social monitoring of children and

  3. N2 gas station and gas distribution system for TLD personnel monitoring gas based semi-automatic badge readers

    International Nuclear Information System (INIS)

    Chourasiya, G.; Pradhan, S.M.; Kher, R.K.; Bhatt, B.C

    2003-01-01

    Full text: New improvised hot gas based Auto TLD badge reader has several advantages over the earlier contact heating based manual badge reader. It requires constant supply of N 2 gas for its operation; The gas supplied using replaceable individual gas cylinders may have some safety hazards in their handling. It was therefore considered worthwhile to setup a N 2 gas assembly/ station outside the lab area and to bring regulated gas supply through network of tubes with proper regulation to the individual readers. The paper presents detailed description of the gas station and distribution system. The system is quite useful and offers several practical advantages for readout of TLD badges on the semiautomatic badge readers based on gas heating. Important advantage from dosimetric point of view is avoidance of gas flow rate fluctuations and corresponding variations in TL readouts

  4. The environmental radiation monitoring system and in-situ measurements for early notification and OIL (Operational Intervention Levels) calculations

    Energy Technology Data Exchange (ETDEWEB)

    Haquin, G.; Ne`eman, E.; Brenner, S.; Lavi, N. [Tel Aviv Univ. (Israel). Sackler School of Medicine. Inst. for Environmental Research

    1997-12-31

    The efficiency of the environmental radiation monitoring, low level laboratory and in-situ gamma-ray spectrometry are evaluated as the systems for early notification and for determination of dose rate in air, surface contamination and activity concentration in food during emergencies for Operational Intervention Levels (OIL) recalculation.The National Environmental Radiation Monitoring System has proved its efficiency in the early detection of unregistered radiography work. A mobile station of the network can be used for absorbed dose rate measurement during emergencies in contaminated areas. The calibrated in-situ gamma-ray spectrometry system in an open phosphate ore mine has showed the efficiency of this technique for fast and accurate determination of soil activity concentration. The calibration for an uniform depth distribution can be easily mathematically converted to an exponential depth distribution in cases of radioactive material fallout 7 refs., 3 figs., 1 tab.; e-mail: envirad at post.tau.ac.il; env{sub r}ad at netvision,net.il

  5. The use of total susceptibility in the analysis of long term PM10 (PM2.5) collected at Hungarian air quality monitoring stations

    Science.gov (United States)

    Márton, Emö; Domján, Ádám; Lautner, Péter; Szentmarjay, Tibor; Uram, János

    2013-04-01

    Air monitoring stations in Hungary are operated by Environmental, Nature Conservancy and Water Pollution Inspectorates, according to the CEN/TC 264 European Union standards. PM10 samples are collected on a 24-hour basis, for two weeks in February, in May, in August and in November. About 720m3 air is pumped through quartz filters daily. Mass measurements and toxic metal analysis (As, Pb, Cd, Ni) are made on each filter (Whatmann DHA-80 PAH, 150 mm diameter) by the inspectorates. We have carried out low field magnetic susceptibility measurements using a KLY-2 instrument on all PM10 samples collected at 9 stations from 2009 on (a total of more than 2000 filters). One station, located far from direct sources, monitors background pollution. Here PM2.5 was also collected in two-week runs, seven times during the period of 2009-2012 and made available for the non-destructive magnetic susceptibility measurements. Due to the rather weak magnetic signal, the susceptibility of each PM-10 sample was computed from 10, that of each PM2.5 sample from 20 measurements. Corrections were made for the susceptibility of the sample holder, for the unpolluted filter (provided with each of the two-week runs), and for the plastic bag containing the samples. The susceptibilities of the PM10 samples were analyzed from different aspects, like the degree of magnetic pollution at different stations, daily and seasonal variations of the total and mass susceptibilities compared to the mass of the pollutants and in relation to the concentrations of the toxic elements. As expected, the lowest total and mass susceptibilities characterize the background station (pollution arrives mostly from distant sources, Vienna, Bratislava or even the Sudeten), while the highest values were measured for an industrial town with heavy traffic. At the background station the mass of the PM10 and PM2.5, respectively for the same period are quite similar, while the magnetic susceptibilities are usually higher in the

  6. Hybrid radiation background monitoring in operational control and forecasting of environmental contamination by nuclear power station discharges

    International Nuclear Information System (INIS)

    Ermeev, I.S.; Eremenko, V.A.; Makarov, Y.A.; Matueev, V.V.; Zhernov, V.S.

    1986-01-01

    Rapid developments in nuclear power have stimulated research on monitoring and forecasting environmental radiation pollution (ERP), and in particular the amounts, compositions, and distributions of radionuclides in the environment. A conceptual model is presented for hybrid environmental radiation pollution monitoring. When there is an emergency, the model operates in a fashion most closely corresponding to the actual meteorological conditions, and the ERP data given by the model enable one to distinguish changes due to the man-made component from random fluctuations in the natural background. The measurement system in general includes mobile and stationary data-acquisition facilities linked by wire or radio to the central point. The system also accumulates and stores data on the radiation environment, which are edited on the basis of radioactive, chemical, and other transformations. The purpose of hybrid monitoring is ultimately to analyze trends in order to detect elevated discharges and thus to output data to the regional monitoring system

  7. The Remote Monitoring of Earth’s Atmosphere Based on Operative Processing GNSS Data in the UA-EUPOS/ZAKPOS Network of Active Reference Stations

    Directory of Open Access Journals (Sweden)

    Nataliya Kablak

    2016-04-01

    Full Text Available The system of remote monitoring of atmosphere is designed to obtain information about the state of atmosphere. The principle of the remote monitoring of atmosphere is based on registering and processing GLONASS/GPS radio signals. Modern networks of active reference stations allow us to solve both practical problems of geodesy, navigation, and purely scientific problems that are important in all geosciences. The paper investigates a spatiotemporal instability in the atmosphere, based on 845 temporal measurements of tropospheric delay over the territory covered by 20 active reference stations of the UA-EUPOS/ZAKPOS network. The method elaborated by the authors for the determination of tropospheric delay in the UA-EUPOS/ZAKPOS network in real time takes relief of the region into account. The results are very good, since mapping tropospheric delay can be made with an average RMSE of 1.5 mm. The method developed in this research can be used to improve the quality of weather forecasts and the prevention of natural disasters.

  8. In-Flight Water Quality Monitoring on the International Space Station (ISS): Measuring Biocide Concentrations with Colorimetric Solid Phase Extraction (CSPE)

    Science.gov (United States)

    Gazda, Daniel B.; Schultz, John R.; Siperko, Lorraine M.; Porter, Marc D.; Lipert, Robert J.; Flint, Stephanie M.; McCoy, J. Torin

    2011-01-01

    The colorimetric water quality monitoring kit (CWQMK) was delivered to the International Space Station (ISS) on STS-128/17A and was initially deployed in September 2009. The kit was flown as a station development test objective (SDTO) experiment to evaluate the acceptability of colorimetric solid phase extraction (CSPE) technology for routine water quality monitoring on the ISS. During the SDTO experiment, water samples from the U.S. water processor assembly (WPA), the U.S. potable water dispenser (PWD), and the Russian system for dispensing ground-supplied water (SVO-ZV) were collected and analyzed with the CWQMK. Samples from the U.S. segment of the ISS were analyzed for molecular iodine, which is the biocide added to water in the WPA. Samples from the SVOZV system were analyzed for ionic silver, the biocide used on the Russian segment of the ISS. In all, thirteen in-flight analysis sessions were completed as part of the SDTO experiment. This paper provides an overview of the experiment and reports the results obtained with the CWQMK. The forward plan for certifying the CWQMK as operational hardware and expanding the capabilities of the kit are also discussed.

  9. Type GQS-1 high pressure steam manifold water level monitoring system

    International Nuclear Information System (INIS)

    Li Nianzu; Li Beicheng; Jia Shengming

    1993-10-01

    The GQS-1 high pressure steam manifold water level monitoring system is an advanced nuclear gauge that is suitable for on-line detecting and monitor in high pressure steam manifold water level. The physical variable of water level is transformed into electrical pulses by the nuclear sensor. A computer is equipped for data acquisition, analysis and processing and the results are displayed on a 14 inch color monitor. In addition, a 4 ∼ 20 mA output current is used for the recording and regulation of water level. The main application of this gauge is for on-line measurement of high pressure steam manifold water level in fossil-fired power plant and other industries

  10. Frameworks to monitor and predict resource usage in the ATLAS High Level Trigger

    CERN Document Server

    Martin, Tim; The ATLAS collaboration

    2016-01-01

    The ATLAS High Level Trigger Farm consists of around 30,000 CPU cores which filter events at up to 100 kHz input rate. A costing framework is built into the high level trigger, this enables detailed monitoring of the system and allows for data-driven predictions to be made utilising specialist datasets. This talk will present an overview of how ATLAS collects in-situ monitoring data on both CPU usage and dataflow over the data-acquisition network during the trigger execution, and how these data are processed to yield both low level monitoring of individual selection-algorithms and high level data on the overall performance of the farm. For development and prediction purposes, ATLAS uses a special `Enhanced Bias' event selection. This mechanism will be explained along with how is used to profile expected resource usage and output event-rate of new physics selections, before they are executed on the actual high level trigger farm.

  11. Frameworks to monitor and predict rates and resource usage in the ATLAS High Level Trigger

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00219969; The ATLAS collaboration

    2017-01-01

    The ATLAS High Level Trigger Farm consists of around 40,000 CPU cores which filter events at an input rate of up to 100 kHz. A costing framework is built into the high level trigger thus enabling detailed monitoring of the system and allowing for data-driven predictions to be made utilising specialist datasets. An overview is presented in to how ATLAS collects in-situ monitoring data on CPU usage during the trigger execution, and how these data are processed to yield both low level monitoring of individual selection-algorithms and high level data on the overall performance of the farm. For development and prediction purposes, ATLAS uses a special ‘Enhanced Bias’ event selection. This mechanism is explained along with how it is used to profile expected resource usage and output event rate of new physics selections, before they are executed on the actual high level trigger farm.

  12. Ethical issues in using Twitter for population-level depression monitoring: a qualitative study.

    Science.gov (United States)

    Mikal, Jude; Hurst, Samantha; Conway, Mike

    2016-04-14

    Recently, significant research effort has focused on using Twitter (and other social media) to investigate mental health at the population-level. While there has been influential work in developing ethical guidelines for Internet discussion forum-based research in public health, there is currently limited work focused on addressing ethical problems in Twitter-based public health research, and less still that considers these issues from users' own perspectives. In this work, we aim to investigate public attitudes towards utilizing public domain Twitter data for population-level mental health monitoring using a qualitative methodology. The study explores user perspectives in a series of five, 2-h focus group interviews. Following a semi-structured protocol, 26 Twitter users with and without a diagnosed history of depression discussed general Twitter use, along with privacy expectations, and ethical issues in using social media for health monitoring, with a particular focus on mental health monitoring. Transcripts were then transcribed, redacted, and coded using a constant comparative approach. While participants expressed a wide range of opinions, there was an overall trend towards a relatively positive view of using public domain Twitter data as a resource for population level mental health monitoring, provided that results are appropriately aggregated. Results are divided into five sections: (1) a profile of respondents' Twitter use patterns and use variability; (2) users' privacy expectations, including expectations regarding data reach and permanence; (3) attitudes towards social media based population-level health monitoring in general, and attitudes towards mental health monitoring in particular; (4) attitudes towards individual versus population-level health monitoring; and (5) users' own recommendations for the appropriate regulation of population-level mental health monitoring. Focus group data reveal a wide range of attitudes towards the use of public

  13. [Risk-oriented model of the control of the level of electric magnetic fields of base stations of cellular communications].

    Science.gov (United States)

    Lutsenko, L A; Tulakin, A V; Egorova, A M; Mikhailova, O M; Gvozdeva, L L; Chigryay, E K

    The purpose of this study was to give the description of harmful effects of the impact of electromagnetic radiations from base stations of cellular communication as the most common sources of radio frequencies of electromagnetic fields in the environment. The highest values of the energy flux density were measured on the roofs of houses where antennas are installed - more than 10 pW/cm. The lowest values were recorded in inside premises with expositions of 0.1-1 pW/cm. In the close location of the railway station to the base stations of the cellular communication there was seen a cumulative effect. There are proposed both new safe hygienic approaches to the control for the safety of the work of base station and protective measures.

  14. The Investigation of Hourly,Daily and Seasonal Changes of Duzce Air Quality Monitoring Station 2014 Data

    Directory of Open Access Journals (Sweden)

    Filiz Bolu

    2015-10-01

    Full Text Available Aim: To evaluate data of air quality in the year 2004 in Duzce by days, hours and seasons. Method: In this study, sulfur dioxide, particulate matter levels, wind speed and wind direction values of Duzce city center obtained from the web page of Ministry of Envoriment and Planning between 1 January -31 December 2014 were studied. Data were examined by on the time of hours, days, days of the week, months and seasons. Results: Annual average PM10 was 106,42+/-102 and #956;g/m3 , SO2 concentration was 6,15+/-5,39 and #956;g/m3. Winter PM10 and SO2 measurements were significantly higher than summer season. Wind speed in the summer season had a higher average than the winter season. Highest average PM10 was at November 189,4 +/- 171,8 and #956;g/m3. The lowest PM10 was at June 58,0+/-24,5 and #956;g/m3. The highest average wind speed was at June, the lowest average wind speed is at December. PM10 and SO2 measurements were positively correlated with wind direction, shows a negative correlation with wind speed. The highest PM10 measurements in the summer season were on Thursdays, in the winter season on Wednesdays. The lowest PM10 measurements both in two seasons were on Sundays. Average PM10 was significantly higher on weekdays than weekends. The highest PM10 value of 146,6 +/- 131,3 and #956;g/m3 was measured at 23.00. The lowest PM10 value of 73,8+/-55,9 and #956;g/m3 was measured at 15.00. Conclusion: There is air pollution in Duzce both in the summer and winter. Continuous monitoring of the emissions of existing establishments in the industrial pollution control should be provided. The high PM10 measurements in the evening may be due to traffic during the day and fuel use for heating purposes. Widespread use of natural gas and creating socially conscious individual measures can be effective in reducing air pollution. [TAF Prev Med Bull 2015; 14(5.000: 387-393

  15. Promoting health equity: WHO health inequality monitoring at global and national levels

    Directory of Open Access Journals (Sweden)

    Ahmad Reza Hosseinpoor

    2015-09-01

    Full Text Available Background: Health equity is a priority in the post-2015 sustainable development agenda and other major health initiatives. The World Health Organization (WHO has a history of promoting actions to achieve equity in health, including efforts to encourage the practice of health inequality monitoring. Health inequality monitoring systems use disaggregated data to identify disadvantaged subgroups within populations and inform equity-oriented health policies, programs, and practices. Objective: This paper provides an overview of a number of recent and current WHO initiatives related to health inequality monitoring at the global and/or national level. Design: We outline the scope, content, and intended uses/application of the following: Health Equity Monitor database and theme page; State of inequality: reproductive, maternal, newborn, and child health report; Handbook on health inequality monitoring: with a focus on low- and middle-income countries; Health inequality monitoring eLearning module; Monitoring health inequality: an essential step for achieving health equity advocacy booklet and accompanying video series; and capacity building workshops conducted in WHO Member States and Regions. Conclusions: The paper concludes by considering how the work of the WHO can be expanded upon to promote the establishment of sustainable and robust inequality monitoring systems across a variety of health topics among Member States and at the global level.

  16. Promoting health equity: WHO health inequality monitoring at global and national levels.

    Science.gov (United States)

    Hosseinpoor, Ahmad Reza; Bergen, Nicole; Schlotheuber, Anne

    2015-01-01

    Health equity is a priority in the post-2015 sustainable development agenda and other major health initiatives. The World Health Organization (WHO) has a history of promoting actions to achieve equity in health, including efforts to encourage the practice of health inequality monitoring. Health inequality monitoring systems use disaggregated data to identify disadvantaged subgroups within populations and inform equity-oriented health policies, programs, and practices. This paper provides an overview of a number of recent and current WHO initiatives related to health inequality monitoring at the global and/or national level. We outline the scope, content, and intended uses/application of the following: Health Equity Monitor database and theme page; State of inequality: reproductive, maternal, newborn, and child health report; Handbook on health inequality monitoring: with a focus on low- and middle-income countries; Health inequality monitoring eLearning module; Monitoring health inequality: an essential step for achieving health equity advocacy booklet and accompanying video series; and capacity building workshops conducted in WHO Member States and Regions. The paper concludes by considering how the work of the WHO can be expanded upon to promote the establishment of sustainable and robust inequality monitoring systems across a variety of health topics among Member States and at the global level.

  17. Promoting health equity: WHO health inequality monitoring at global and national levels

    Science.gov (United States)

    Hosseinpoor, Ahmad Reza; Bergen, Nicole; Schlotheuber, Anne

    2015-01-01

    Background Health equity is a priority in the post-2015 sustainable development agenda and other major health initiatives. The World Health Organization (WHO) has a history of promoting actions to achieve equity in health, including efforts to encourage the practice of health inequality monitoring. Health inequality monitoring systems use disaggregated data to identify disadvantaged subgroups within populations and inform equity-oriented health policies, programs, and practices. Objective This paper provides an overview of a number of recent and current WHO initiatives related to health inequality monitoring at the global and/or national level. Design We outline the scope, content, and intended uses/application of the following: Health Equity Monitor database and theme page; State of inequality: reproductive, maternal, newborn, and child health report; Handbook on health inequality monitoring: with a focus on low- and middle-income countries; Health inequality monitoring eLearning module; Monitoring health inequality: an essential step for achieving health equity advocacy booklet and accompanying video series; and capacity building workshops conducted in WHO Member States and Regions. Conclusions The paper concludes by considering how the work of the WHO can be expanded upon to promote the establishment of sustainable and robust inequality monitoring systems across a variety of health topics among Member States and at the global level. PMID:26387506

  18. On-line vibration and loose parts monitoring of nuclear power stations as a preventive maintenance tool

    International Nuclear Information System (INIS)

    An equipment for on-line monitoring of vibrations and loose parts of nuclear power plants is described. The unit consists of piezoelectric transducers, preamplifiers, a data processor, and peripherals. It secures on-line measurement without interfering with the operation of the power plant. A diagram is given showing the monitor of vibrations and loose parts for pressurized water reactors and the Spectra-Scan equipment for the automatic recording and computer processing of noise signals is described. A survey is given of diagnostic methods for internal vibrations, noise and oscillations and procedures for the analysis of recordings are described. The experiences of Atomica International with the observation of vibrations in nuclear power plants are described and an economic assessment is presented of the efficiency of on-line monitoring of these vibrations. A cost-benefit analysis is made of such equipment which justifies their introduction. (B.S.)

  19. A distributed fluid level sensor suitable for monitoring fuel load on board a moving fuel tank

    Science.gov (United States)

    Arkwright, John W.; Parkinson, Luke A.; Papageorgiou, Anthony W.

    2018-02-01

    A temperature insensitive fiber Bragg grating sensing array has been developed for monitoring fluid levels in a moving tank. The sensors are formed from two optical fibers twisted together to form a double helix with pairs of fiber Bragg gratings located above one another at the points where the fibers are vertically disposed. The sensing mechanism is based on a downwards deflection of the section of the double helix containing the FBGs which causes the tension in the upper FBG to decrease and the tension in the lower FBG to increase with concomitant changes in Bragg wavelength in each FBG. Changes in ambient temperature cause a common mode increase in Bragg wavelength, thus monitoring the differential change in wavelength provides a temperature independent measure of the applied pressure. Ambient temperature can be monitored simultaneously by taking the average wavelength of the upper and lower FBGs. The sensors are able to detect variations in pressure with resolutions better than 1 mmH2O and when placed on the bottom of a tank can be used to monitor fluid level based on the recorded pressure. Using an array of these sensors located along the bottom of a moving tank it was possible to monitor the fluid level at multiple points and hence dynamically track the total fluid volume in the tank. The outer surface of the sensing array is formed from a thin continuous Teflon sleeve, making it suitable for monitoring the level of volatile fluids such as aviation fuel and gasoline.

  20. CO2 Fluxes Monitoring at the Level of Field Agroecosystem in Moscow Region of Russia

    Science.gov (United States)

    Meshalkina, Joulia; Mazirov, Ilya; Samardzic, Miljan; Yaroslavtsev, Alexis; Valentini, Riccardo; Vasenev, Ivan

    2014-05-01

    The Central Russia is still one of the less GHG-investigated European areas especially in case of agroecosystem-level carbon dioxide fluxes monitoring by eddy covariance method. The eddy covariance technique is a statistical method to measure and calculate vertical turbulent fluxes within atmospheric boundary layers. The major assumption of the metod is that measurements at a point can represent an entire upwind area. Eddy covariance researches, which could be considered as repeated for the same area, are very rare. The research has been carried out on the Precision Farming Experimental Field of the Russian Timiryazev State Agricultural University (Moscow, Russia) in 2013 under the support of RF Government grant No. 11.G34.31.0079. Arable derno-podzoluvisls have around 1 The results have shown high daily and seasonal dynamic of agroecosystem CO2 emission. Sowing activates soil microbiological activity and the average soil CO2 emission and adsorption are rising at the same time. CO2 streams are intensified after crop emerging from values of 3 to 7 μmol/s-m2 for emission, and from values of 5 to 20 μmol/s-m2 for adsorption. Stabilization of the flow has come at achieving plants height of 10-12 cm. The vegetation period is characterized by high average soil CO2 emission and adsorption at the same time, but the adsorption is significantly higher. The resulted CO2 absorption during the day is approximately 2-5 times higher than emissions at night. For example, in mid-June, the absorption value was about 0.45 mol/m2 during the day-time, and the emission value was about 0.1 mol/m2 at night. After harvesting CO2 emission is becoming essentially higher than adsorption. Autumn and winter data are fluctuate around zero, but for some periods a small predominance of CO2 emissions over the absorption may be observed. The daily dynamics of CO2 emissions depends on the air temperature with the correlation coefficient changes between 0.4 and 0.8. Crop stage, agrotechnological

  1. Object-oriented Approach to High-level Network Monitoring and Management

    Science.gov (United States)

    Mukkamala, Ravi

    2000-01-01

    An absolute prerequisite for the management of large investigating methods to build high-level monitoring computer networks is the ability to measure their systems that are built on top of existing monitoring performance. Unless we monitor a system, we cannot tools. Due to the heterogeneous nature of the hope to manage and control its performance. In this underlying systems at NASA Langley Research Center, paper, we describe a network monitoring system that we use an object-oriented approach for the design, we are currently designing and implementing. Keeping, first, we use UML (Unified Modeling Language) to in mind the complexity of the task and the required model users' requirements. Second, we identify the flexibility for future changes, we use an object-oriented existing capabilities of the underlying monitoring design methodology. The system is built using the system. Third, we try to map the former with the latter. APIs offered by the HP OpenView system.

  2. An assessment of invasive plant species monitored by the Northern Research Station Forest Inventory and Analysis Program, 2005 through 2010

    Science.gov (United States)

    Cassandra M. Kurtz

    2013-01-01

    Invasive plant species are a worldwide concern due to the high ecological and economic costs associated with their presence. This document describes the plant characteristics and regional distribution of the 50 invasive plant species monitored from 2005 through 2010 on forested Phase 2 (P2) Forest Inventory and Analysis (FIA) plots in the 24 states of the Northern...

  3. Nutrient balances at farm level in Machakos (Kenya), using a participatory nutrient monitoring (NUTMON) approach

    NARCIS (Netherlands)

    Gachimbi, L.N.; Keulen, van H.; Thuranira, E.G.; Karuku, A.M.; Jager, de A.; Nguluu, S.; Ikombo, B.M.; Kinama, J.M.; Itabari, J.K.; Nandwa, S.M.

    2005-01-01

    A total of 74 farms were selected from Machakos, Mwingi and Makueni districts in Kenya, using participatory techniques and classified in three categories on the basis of soil fertility management (low level, medium and high level). Soil fertility management was monitored, using the NUTrient

  4. Monitoring sea level and sea surface temperature trends from ERS satellites

    DEFF Research Database (Denmark)

    Andersen, Ole Baltazar; Knudsen, Per; Beckley, B.

    2002-01-01

    Data from the two ESA satellites ERS-1 and ERS-2 are used in global and regional analysis of sea level and sea surface temperature trends over the last, 7.8 years. T he ERS satellites and in the future the ENVISAT satellite provide unique opportunity for monitoring both changes in sea level and sea...

  5. Trace elements in aerosols from background air pollution monitoring stations in the Amazon Basin using nuclear-related techniques

    International Nuclear Information System (INIS)

    Artaxo, P.; Martins, J.V.; Yamasoe, M.A.; Gerab, F.; Kocinas, S.

    1994-01-01

    In order to study the natural release of aerosol particles by the Amazon Basin tropical rain forest, the composition and size distribution of biogenic aerosol particles were analyzed. The role of the atmospheric emissions from the Amazon Basin rain forest in the global atmosphere will be investigated. The atmosphere was studied in long-term sampling stations in three different locations. The elemental composition of aerosol particles released during biomass burning was also measured in several different ecosystems, from primary forest to Savannah. One of the main focuses was to identify and quantify important physical and chemical processes in the generation, transformation and deposition of aerosol particles. Also important was to obtain a better understanding of natural aerosol sources concerning identification, their characteristics and strength, to be able to understand the natural chemistry in the atmosphere on a global scale. 36 refs, 3 figs, 3 tabs

  6. Structure of carbon monoxide time variations in the atmospheric thickness over Central Eurasia (Issyk Kul Monitoring Station)

    Science.gov (United States)

    Aref'ev, V. N.; Kashin, F. V.; Orozaliev, M. D.; Sizov, N. I.; Sinyakov, V. P.; Sorokina, L. I.

    2013-03-01

    The results of measurements of the CO content in the atmospheric thickness by the method of solar molecular-absorption spectroscopy are presented. Over 87 months of observations, the annual mean CO content decreased by ˜19% at a mean rate of changes equal to -(0.14 ± 0.02) atm cm per year. Maxima and minima of seasonal variations most often fall on February and September, respectively. The mean overall amplitude of changes in the CO content during the annual cycle is about 50% of the mean value. The Fourier analysis revealed variations in the CO composition with periods from 3 to 84 months. A simple statistical model satisfactorily describes time changes in the CO content in the atmospheric thickness. The results of measurements of the CO content in the atmospheric thickness are compared with the data of CO measurements in samples of surface air at stations of the Global Atmospheric Watch.

  7. The development and testing of a volatile organics concentrator for use in monitoring Space Station water quality

    Science.gov (United States)

    Bodek, Itamar; Ehntholt, Daniel J.; Stolki, Thomas J.; Trabanino, Rudy; Hinsdale, Lloyd; Webb, Johanna; Sauer, Richard L.

    1992-01-01

    The Volatile Organics Concentrator (VOC) system, designed to attach to a gas chromatograph/mass spectrometer (GC/MS) for the analyses of volatile organic compounds in water on Space Station Freedom, is described. Organic volatiles are collected and concentrated in the VOC by means of two primary solid sorbent tubes and desorbed into the GC/MS system. The paper describes the results of testing the VOC breadboard using a GC/MS system. Evaluations performed on 39 organic compounds recovered from water samples were compared with data for these compounds using direct injection/GC/MS and purge and trap/GC/MS procedures. The results demonstrate that the VOC/GC/MS system's detection limits for the 39 compounds analyzed are comparable to those of the EPA Method 524.2, and for many compounds reaching a factor of 5 lower.

  8. A real-time monitoring and assessment method for calculation of total amounts of indoor air pollutants emitted in subway stations.

    Science.gov (United States)

    Oh, TaeSeok; Kim, MinJeong; Lim, JungJin; Kang, OnYu; Shetty, K Vidya; SankaraRao, B; Yoo, ChangKyoo; Park, Jae Hyung; Kim, Jeong Tai

    2012-05-01

    Subway systems are considered as main public transportation facility in developed countries. Time spent by people in indoors, such as underground spaces, subway stations, and indoor buildings, has gradually increased in the recent past. Especially, operators or old persons who stay in indoor environments more than 15 hr per day usually influenced a greater extent by indoor air pollutants. Hence, regulations on indoor air pollutants are needed to ensure good health of people. Therefore, in this study, a new cumulative calculation method for the estimation of total amounts of indoor air pollutants emitted inside the subway station is proposed by taking cumulative amounts of indoor air pollutants based on integration concept. Minimum concentration of individual air pollutants which naturally exist in indoor space is referred as base concentration of air pollutants and can be found from the data collected. After subtracting the value of base concentration from data point of each data set of indoor air pollutant, the primary quantity of emitted air pollutant is calculated. After integration is carried out with these values, adding the base concentration to the integration quantity gives the total amount of indoor air pollutant emitted. Moreover the values of new index for cumulative indoor air quality obtained for 1 day are calculated using the values of cumulative air quality index (CAI). Cumulative comprehensive indoor air quality index (CCIAI) is also proposed to compare the values of cumulative concentrations of indoor air pollutants. From the results, it is clear that the cumulative assessment approach of indoor air quality (IAQ) is useful for monitoring the values of total amounts of indoor air pollutants emitted, in case of exposure to indoor air pollutants for a long time. Also, the values of CCIAI are influenced more by the values of concentration of NO2, which is released due to the use of air conditioners and combustion of the fuel. The results obtained in

  9. Measurement and Analysis of Radio-frequency Radiation Exposure Level from Different Mobile Base Transceiver Stations in Ajaokuta and Environs, Nigeria

    OpenAIRE

    Ushie, P. O.; Nwankwo, Victor U. J.; Bolaji, Ayinmode; Osahun, O. D.

    2013-01-01

    We present the result of a preliminary assessment of radio-frequency radiation exposure from selected mobile base stations in Ajaokuta environs. The Power density of RF radiation within a radial distance of 125m was measured. Although values fluctuated due to the influence of other factors, including wave interference from other electromagnetic sources around reference base stations, we show from analysis that radiation exposure level is below the standard limit (4.5W/sqm for 900MHz and 9W/sq...

  10. Hydrate research activities that both support and derive from the monitoring station/sea-floor Observatory, Mississippi Canyon 118, northern Gulf of Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Lutken, Carol [Univ. of Mississippi, Oxford, MS (United States). Center for Marine Resources and Environmental Technology (CMRET)

    2013-07-31

    A permanent observatory has been installed on the seafloor at Federal Lease Block, Mississippi Canyon 118 (MC118), northern Gulf of Mexico. Researched and designed by the Gulf of Mexico Hydrates Research Consortium (GOM-HRC) with the geological, geophysical, geochemical and biological characterization of in situ gas hydrates systems as the research goal, the site has been designated by the Bureau of Ocean Energy Management as a permanent Research Reserve where studies of hydrates and related ocean systems may take place continuously and cooperatively into the foreseeable future. The predominant seafloor feature at MC118 is a carbonate-hydrate complex, officially named Woolsey Mound for the founder of both the GOM-HRC and the concept of the permanent seafloor hydrates research facility, the late James Robert “Bob” Woolsey. As primary investigator of the overall project until his death in mid-2008, Woolsey provided key scientific input and served as chief administrator for the Monitoring Station/ Seafloor Observatory (MS-SFO). This final technical report presents highlights of research and accomplishments to date. Although not all projects reached the status originally envisioned, they are all either complete or positioned for completion at the earliest opportunity. All Department of Energy funds have been exhausted in this effort but, in addition, leveraged to great advantage with additional federal input to the project and matched efforts and resources. This report contains final reports on all subcontracts issued by the University of Mississippi, Administrators of the project, Hydrate research activities that both support and derive from the monitoring station/sea-floor Observatory, Mississippi Canyon 118, northern Gulf of Mexico, as well as status reports on the major components of the project. All subcontractors have fulfilled their primary obligations. Without continued funds designated for further project development, the Monitoring Station

  11. CryoSat-2 altimetry for river level monitoring - Evaluation in the Ganges-Brahmaputra River basin

    DEFF Research Database (Denmark)

    Villadsen, Heidi; Andersen, Ole B.; Stenseng, Lars

    2015-01-01

    , the results from the method developed in this study involving virtual stations show that the CryoSat-2 data can indeed be used for such monitoring by utilizing the high spatial coverage and the sub-cycle period of 30 days. The results show that it is possible to capture the peak flow occurring during late...

  12. Water Level Loggers as a Low-Cost Tool for Monitoring of Stormwater Control Measures

    Directory of Open Access Journals (Sweden)

    Laura Toran

    2016-08-01

    Full Text Available Stormwater control measures (SCMs are a key component of watershed health in urbanized areas. SCMs are used to increase infiltration and reduce discharge to streams or storm sewer systems during rain events. Monitoring is important for the evaluation of design and causes of failure in SCMs. However, the expense of monitoring means it is not always included in stormwater control planning. This study shows how low-cost water level loggers can be used to answer certain questions about SCM performance. Five case studies are presented that use water level loggers to evaluate the overflow of basins, compare a traditional stormpipe trench with an infiltration trench, monitor timing of blue roof storage, show the effects of retrofitting a basin, and provide long term performance data. Water level loggers can be used to answer questions about the timing and location of stormwater overflows, which helps to evaluate the effectiveness of SCMs. More expensive monitoring and modeling can be used as a follow up if needed to more thoroughly assess a site. Nonetheless, low-cost monitoring can be a first step in identifying sites that need improvement or additional monitoring.

  13. Study of the Cherokee Nuclear Station: projected impacts, monitoring plan, and mitigation options for Cherokee County, South Carolina

    International Nuclear Information System (INIS)

    Peelle, E.; Schweitzer, M.; Scharre, P.; Pressman, B.

    1979-07-01

    This report inventories Cherokee County's capabilities and CNS project characteristics, projects expected impacts from the interaction of the two defines four options for Cherokee County decision makers, and presents a range of possible mitigation and monitoring plans for dealing with the problems identified. The four options and general implementation guidelines for each are presented after reviewing pertinent features of other mitigation and monitoring plans. The four options include (1) no action, (2) preventing impacts by preventing growth, (3) selective growth in designated areas as services can be supplied, and (4) maximum growth designed to attract as many in-movers as possible through a major program of capital investiments in public and private services. With the exception of the no action option, all plans deal with impacts according to some strategy determined by how the County wishes to manage growth. Solutions for impact problems depend on which growth strategy is selected and what additional resources are secured during the impact period. A monitoring program deals with the problems of data and projections uncertainty, while direct action is proposed to deal with the institutional problems of delay of the needed access road, timeing and location problems from the tax base mismatch, and lack of local planning capability

  14. Study of the Cherokee Nuclear Station: projected impacts, monitoring plan, and mitigation options for Cherokee County, South Carolina

    Energy Technology Data Exchange (ETDEWEB)

    Peelle, E.; Schweitzer, M.; Scharre, P.; Pressman, B.

    1979-07-01

    This report inventories Cherokee County's capabilities and CNS project characteristics, projects expected impacts from the interaction of the two defines four options for Cherokee County decision makers, and presents a range of possible mitigation and monitoring plans for dealing with the problems identified. The four options and general implementation guidelines for each are presented after reviewing pertinent features of other mitigation and monitoring plans. The four options include (1) no action, (2) preventing impacts by preventing growth, (3) selective growth in designated areas as services can be supplied, and (4) maximum growth designed to attract as many in-movers as possible through a major program of capital investiments in public and private services. With the exception of the no action option, all plans deal with impacts according to some strategy determined by how the County wishes to manage growth. Solutions for impact problems depend on which growth strategy is selected and what additional resources are secured during the impact period. A monitoring program deals with the problems of data and projections uncertainty, while direct action is proposed to deal with the institutional problems of delay of the needed access road, timeing and location problems from the tax base mismatch, and lack of local planning capability.

  15. Monitoring Street-Level Spatial-Temporal Variations of Carbon Monoxide in Urban Settings Using a Wireless Sensor Network (WSN Framework

    Directory of Open Access Journals (Sweden)

    Tzai-Hung Wen

    2013-11-01

    Full Text Available Air pollution has become a severe environmental problem due to urbanization and heavy traffic. Monitoring street-level air quality is an important issue, but most official monitoring stations are installed to monitor large-scale air quality conditions, and their limited spatial resolution cannot reflect the detailed variations in air quality that may be induced by traffic jams. By deploying wireless sensors on crossroads and main roads, this study established a pilot framework for a wireless sensor network (WSN-based real-time monitoring system to understand street-level spatial-temporal changes of carbon monoxide (CO in urban settings. The system consists of two major components. The first component is the deployment of wireless sensors. We deployed 44 sensor nodes, 40 transmitter nodes and four gateway nodes in this study. Each sensor node includes a signal processing module, a CO sensor and a wireless communication module. In order to capture realistic human exposure to traffic pollutants, all sensors were deployed at a height of 1.5 m on lampposts and traffic signs. The study area covers a total length of 1.5 km of Keelung Road in Taipei City. The other component is a map-based monitoring platform for sensor data visualization and manipulation in time and space. Using intensive real-time street-level monitoring framework, we compared the spatial-temporal patterns of air pollution in different time periods. Our results capture four CO concentration peaks throughout the day at the location, which was located along an arterial and nearby traffic sign. The hourly average could reach 5.3 ppm from 5:00 pm to 7:00 pm due to the traffic congestion. The proposed WSN-based framework captures detailed ground information and potential risk of human exposure to traffic-related air pollution. It also provides street-level insights into real-time monitoring for further early warning of air pollution and urban environmental management.

  16. Monitoring street-level spatial-temporal variations of carbon monoxide in urban settings using a wireless sensor network (WSN) framework.

    Science.gov (United States)

    Wen, Tzai-Hung; Jiang, Joe-Air; Sun, Chih-Hong; Juang, Jehn-Yih; Lin, Tzu-Shiang

    2013-11-27

    Air pollution has become a severe environmental problem due to urbanization and heavy traffic. Monitoring street-level air quality is an important issue, but most official monitoring stations are installed to monitor large-scale air quality conditions, and their limited spatial resolution cannot reflect the detailed variations in air quality that may be induced by traffic jams. By deploying wireless sensors on crossroads and main roads, this study established a pilot framework for a wireless sensor network (WSN)-based real-time monitoring system to understand street-level spatial-temporal changes of carbon monoxide (CO) in urban settings. The system consists of two major components. The first component is the deployment of wireless sensors. We deployed 44 sensor nodes, 40 transmitter nodes and four gateway nodes in this study. Each sensor node includes a signal processing module, a CO sensor and a wireless communication module. In order to capture realistic human exposure to traffic pollutants, all sensors were deployed at a height of 1.5 m on lampposts and traffic signs. The study area covers a total length of 1.5 km of Keelung Road in Taipei City. The other component is a map-based monitoring platform for sensor data visualization and manipulation in time and space. Using intensive real-time street-level monitoring framework, we compared the spatial-temporal patterns of air pollution in different time periods. Our results capture four CO concentration peaks throughout the day at the location, which was located along an arterial and nearby traffic sign. The hourly average could reach 5.3 ppm from 5:00 pm to 7:00 pm due to the traffic congestion. The proposed WSN-based framework captures detailed ground information and potential risk of human exposure to traffic-related air pollution. It also provides street-level insights into real-time monitoring for further early warning of air pollution and urban environmental management.

  17. Monitoring Street-Level Spatial-Temporal Variations of Carbon Monoxide in Urban Settings Using a Wireless Sensor Network (WSN) Framework

    Science.gov (United States)

    Wen, Tzai-Hung; Jiang, Joe-Air; Sun, Chih-Hong; Juang, Jehn-Yih; Lin, Tzu-Shiang

    2013-01-01

    Air pollution has become a severe environmental problem due to urbanization and heavy traffic. Monitoring street-level air quality is an important issue, but most official monitoring stations are installed to monitor large-scale air quality conditions, and their limited spatial resolution cannot reflect the detailed variations in air quality that may be induced by traffic jams. By deploying wireless sensors on crossroads and main roads, this study established a pilot framework for a wireless sensor network (WSN)-based real-time monitoring system to understand street-level spatial-temporal changes of carbon monoxide (CO) in urban settings. The system consists of two major components. The first component is the deployment of wireless sensors. We deployed 44 sensor nodes, 40 transmitter nodes and four gateway nodes in this study. Each sensor node includes a signal processing module, a CO sensor and a wireless communication module. In order to capture realistic human exposure to traffic pollutants, all sensors were deployed at a height of 1.5 m on lampposts and traffic signs. The study area covers a total length of 1.5 km of Keelung Road in Taipei City. The other component is a map-based monitoring platform for sensor data visualization and manipulation in time and space. Using intensive real-time street-level monitoring framework, we compared the spatial-temporal patterns of air pollution in different time periods. Our results capture four CO concentration peaks throughout the day at the location, which was located along an arterial and nearby traffic sign. The hourly average could reach 5.3 ppm from 5:00 pm to 7:00 pm due to the traffic congestion. The proposed WSN-based framework captures detailed ground information and potential risk of human exposure to traffic-related air pollution. It also provides street-level insights into real-time monitoring for further early warning of air pollution and urban environmental management. PMID:24287859

  18. Precision and costs of techniques for self-monitoring of serum glucose levels.

    OpenAIRE

    Chiasson, J. L.; Morrisset, R.; Hamet, P.

    1984-01-01

    The poor correlation between serum and urine glucose measurements has led to the development of new techniques for monitoring the blood glucose level in diabetic patients. Either a nurse or the patient can perform these tests, which involve spreading a single drop of blood onto a reagent strip. A colour change that is proportional to the serum glucose level can be read visually or with a reflectance meter. Evaluated against simultaneous serum glucose levels determined by the hospital biochemi...

  19. COCONet enhancements to circum-Caribbean tsunami warning, tidal, and sea-level monitoring: update on tide gauge installations

    Science.gov (United States)

    Dausz, K.; Dittmann, S. T.; Feaux, K.; von Hillebrandt-Andrade, C.; Mattioli, G. S.; Normandeau, J.

    2014-12-01

    The Continually Operating Caribbean GPS Observational Network (COCONet) is a National Science Foundation (NSF) funded multi-hazard geodetic and meteorological network distributed throughout the Caribbean, which provides infrastructure and capacity building for a broad range of earth science questions. The network is a multi-national collaboration consisting of 46 newly constructed continuous Global Positioning Systems (cGPS) and 21 refurbished existing GPS stations, all co-located with meteorological sensors. One recommendation of the COCONet working group was to improve the vertical reference frame for long-term sea level monitoring. A COCONet supplement was awarded by the NSF to further address this particular objective through the co-location of GPS and tide gauges. This COCOnet infrastructure, along with the new tide gauges, will have broad scientific implications for hazards mitigation, solid earth, and atmospheric science research. UNAVCO engineers have meet with members of the Caribbean tide gauge community to establish target locations and design station layout. Allocated NSF funds allow for the construction of two complete new tide gauge systems each with two complimentary cGPS. Following the recommendations of NOAA and the sea level monitoring community, the two "new" locales will be Port Royal, Jamaica and Puerto Morelos, Mexico. Both locations had previously existing, but currently non-operational tide gauges. UNAVCO engineers will install a Sutron Radar Level Recorder and a backup pressure sensor tide gauge with GOES satellite telemetry. Tide data will be freely available by the Intergovernmental Oceanographic Commission (www.ioc-sealevelmonitoring.org). The NSF supplement also provided funds for adding cGPS to two additional locations where currently functioning tide gauge systems exist. Proposed locations for this additional infrastructure are Barahona, Dominican Republic and Bocas del Toro, Panama. All four locations will feature two standard

  20. Understanding the Effect of Stratification on Vertical and Temporal Heterogenieties of Cyanobacteria Blooms in Lakes Using a Long Term in-situ Monitoring Station

    Science.gov (United States)

    Wilkinson, A.; Guala, M.; Hondzo, M.

    2017-12-01

    Harmful Algal Blooms (HAB) are made up of potentially toxic freshwater microorganisms called cyanobacteria, because of this they are a ecological and public health hazard. The occurrences of toxic HAB are unpredictable and highly spatially and temporary variable in freshwater ecosystems. To study the abiotic drivers for toxic HAB, a floating research station has been deployed in a hyper-eutrophic lake in Madison Lake, Minnesota, from June-October 2016. This research station provides full depth water quality (hourly) and meteorological monitoring (5 minutes). Water quality monitoring is performed by an autonomously traversed water quality sonde that provides chemical, physical and biological measurements; including phycocyanin, a photosynthetic pigment distinct to cyanobacteria. A bloom of cyanobacteria recorded in the epiliminion in mid-July was driven by prolonged strong thermal stratification in the water column, high surface water temperatures and high phosphate concentrations in the epiliminion. The high biovolume (BV) persisted until late September and was sustained below the surface after stratification weakened, when the thermocline did not confine cyanobacteria-rich layers any more, and cyanobacteria vertical heterogeneities decayed in the water column. High correlations among BV stratification, surface water temperature, and stratification stability informed the development of a quantitative relationship to determine how BV heterogeneities vary with thermal structure in the water column. The BV heterogeneity decreased with thermal stratification stability and surface water temperature, and the dynamic lake stability described by the Lake Number. Finally the location of maximum BV accumulation showed diurnal patterns ie. BV peaks were observed at 1 m depth during the day and deeper layers during the night, which followed patterns in light penetration and thermocline depth. These findings capture cyanobacteria vertical and temporal heterogeneities on a on

  1. Innovation in monitoring: The U.S. Geological Survey Sacramento–San Joaquin River Delta, California, flow-station network

    Science.gov (United States)

    Burau, Jon; Ruhl, Cathy; Work, Paul A.

    2016-01-29

    The U.S. Geological Survey (USGS) installed the first gage to measure the flow of water into California’s Sacramento–San Joaquin River Delta from the Sacramento River in the late 1800s. Today, a network of 35 hydro-acoustic meters measure flow throughout the delta. This region is a critical part of California’s freshwater supply and conveyance system. With the data provided by this flow-station network—sampled every 15 minutes and updated to the web every hour—state and federal water managers make daily decisions about how much freshwater can be pumped for human use, at which locations, and when. Fish and wildlife scientists, working with water managers, also use this information to protect fish species affected by pumping and loss of habitat. The data are also used to help determine the success or failure of efforts to restore ecosystem processes in what has been called the “most managed and highly altered” watershed in the country.

  2. APPLICATION OF ARTIFICIAL NEURAL NETWORKS FOR PREDICTION OF AIR POLLUTION LEVELS IN ENVIRONMENTAL MONITORING

    Directory of Open Access Journals (Sweden)

    Małgorzata Pawul

    2016-09-01

    Full Text Available Recently, a lot of attention was paid to the improvement of methods which are used to air quality forecasting. Artificial neural networks can be applied to model these problems. Their advantage is that they can solve the problem in the conditions of incomplete information, without the knowledge of the analytical relationship between the input and output data. In this paper we applied artificial neural networks to predict the PM 10 concentrations as factors determining the occurrence of smog phenomena. To create these networks we used meteorological data and concentrations of PM 10. The data were recorded in 2014 and 2015 at three measuring stations operating in Krakow under the State Environmental Monitoring. The best results were obtained by three-layer perceptron with back-propagation algorithm. The neural networks received a good fit in all cases.

  3. Development of elements of the condition monitoring system of turbo generators of thermal power stations and nuclear power plants

    Science.gov (United States)

    Kumenko, A. I.; Kostyukov, V. N.; Kuz'minykh, N. Yu.; Boichenko, S. N.; Timin, A. V.

    2017-08-01

    The rationale is given for the improvement of the regulatory framework for the use of shaft sensors for the in-service condition monitoring of turbo generators and the development of control systems of shaft surfacing and misalignments of supports. A modern concept and a set of methods are proposed for the condition monitoring of the "shaft line-thrust bearing oil film-turbo generator supports" system elements based on the domestic COMPACS® technology. The system raw data are design, technology, installation, and operating parameters of the turbo generator as well as measured parameters of the absolute vibration of supports and mechanical quantities, relative displacements and relative vibration of the rotor teeth in accordance with GOST R 55263-2012. The precalculated shaft line assembly line in the cold state, the nominal parameters of rotor teeth positions on the dynamic equilibrium curve, the static and dynamic characteristics of the oil film of thrust bearings, and the shaft line stiffness matrix of unit support displacements have been introduced into the system. Using the COMPACS-T system, it is planned to measure positions and oscillations of rotor teeth, to count corresponding static and dynamic characteristics of the oil film, and the static and dynamic loads in the supports in real time. Using the obtained data, the system must determine the misalignments of supports and corrective alignments of rotors of coupling halves, voltages in rotor teeth, welds, and bolts of the coupling halves, and provide automatic conclusion if condition monitoring parameters correspond to standard values. A part of the methodological support for the proposed system is presented, including methods for determining static reactions of supports under load, the method for determining shaft line stiffness matrices, and the method for solving the inverse problem, i.e., the determination of the misalignments of the supports by measurements of rotor teeth relative positions in bearing

  4. On the problems of monitoring the total alpha acitivity concentration of the air in the vicinity of nuclear power stations

    International Nuclear Information System (INIS)

    Winkler, R.; Hoetzl, H.

    1983-01-01

    The immission measurement of alpha rays as an environmental monitoring programme is necessary for the production and processing of fuel elements and the WAA. Keeping within the dose limits according to Strl Sch V can only be achieved, if the important radio nuclides are detected with a detection limit, which corresponds to 1130 of the dose limits. For Pu 239/240, this is 3.7 x 10 -6 Bg/m 3 (0.1 f Cu/m 3 ). These detection limits can be achieved by analysis of individual nuclides. (DG) [de

  5. Working level measurement of radon daughters and thoron daughters by personal dosimetry and continuous monitoring

    International Nuclear Information System (INIS)

    Phillips, C.R.; Leung, H.

    1981-01-01

    The performance of personal alpha dosimeters in mixed radon daughter and thoron daughter atmospheres in Ontario uranium mines is described together with monitoring developments which enable the radon daughter working level to be determined separately. The theoretical bases for continuous and integrated working level measurements based on individual and gross counts are presented in terms of the weighting factor for combining the thoron daughter working level with the radon daughter working level, and in terms of the in-growth time of the air. Implications for the determination of working level in the presence of thoron daughters are discussed

  6. Comparison of a continuous working level monitor for radon daughters with conventional grab-sampling

    International Nuclear Information System (INIS)

    Bigu, J.; Grenier, M.

    1982-08-01

    An evaluation of a radon daughter monitor was carried out under laboratory controlled conditions. The monitor operates on continuous sampling and time integrating principles and was tested in conjunction with a newly designed, large radon/thoron room calibration facility. The monitor was tested under constant and rapidly fluctuating radiation conditions. Experimental data obtained with the monitor were compared with data obtained by conventional grab-sampling and with an automated radon daughter/thoron daughter 'grab-sampler'. The Working Level used in the tests ranged from less than 0.01 WL to approximately 10 WL. The measurements were carried out under low aerosol concentration (1 x 10 3 - 2 x 10 3 cm -3 , approximately) to study plate-out effects in the sampling head. Good agreement (within about 10 %) was found between the monitor, conventional grab-sampling and the automated grab-sampler. The monitor should prove quite flexible, useful and reliable for monitoring underground and surface environments in the uranium mining industry

  7. A Bi-Level Optimization Approach to Charging Load Regulation of Electric Vehicle Fast Charging Stations Based on a Battery Energy Storage System

    Directory of Open Access Journals (Sweden)

    Yan Bao

    2018-01-01

    Full Text Available Fast charging stations enable the high-powered rapid recharging of electric vehicles. However, these stations also face challenges due to power fluctuations, high peak loads, and low load factors, affecting the reliable and economic operation of charging stations and distribution networks. This paper introduces a battery energy storage system (BESS for charging load control, which is a more user-friendly approach and is more robust to perturbations. With the goals of peak-shaving, total electricity cost reduction, and minimization of variation in the state-of-charge (SOC range, a BESS-based bi-level optimization strategy for the charging load regulation of fast charging stations is proposed in this paper. At the first level, a day-ahead optimization strategy generates the optimal planned load curve and the deviation band to be used as a reference for ensuring multiple control objectives through linear programming, and even for avoiding control failure caused by insufficient BESS energy. Based on this day-ahead optimal plan, at a second level, real-time rolling optimization converts the control process to a multistage decision-making problem. The predictive control-based real-time rolling optimization strategy in the proposed model was used to achieve the above control objectives and maintain battery life. Finally, through a horizontal comparison of two control approaches in each case study, and a longitudinal comparison of the control robustness against different degrees of load disturbances in three cases, the results indicated that the proposed control strategy was able to significantly improve the charging load characteristics, even with large disturbances. Meanwhile, the proposed approach ensures the least amount of variation in the range of battery SOC and reduces the total electricity cost, which will be of a considerable benefit to station operators.

  8. A distributed monitoring system for photovoltaic arrays based on a two-level wireless sensor network

    Science.gov (United States)

    Su, F. P.; Chen, Z. C.; Zhou, H. F.; Wu, L. J.; Lin, P. J.; Cheng, S. Y.; Li, Y. F.

    2017-11-01

    In this paper, a distributed on-line monitoring system based on a two-level wireless sensor network (WSN) is proposed for real time status monitoring of photovoltaic (PV) arrays to support the fine management and maintenance of PV power plants. The system includes the sensing nodes installed on PV modules (PVM), sensing and routing nodes installed on combiner boxes of PV sub-arrays (PVA), a sink node and a data management centre (DMC) running on a host computer. The first level WSN is implemented by the low-cost wireless transceiver nRF24L01, and it is used to achieve single hop communication between the PVM nodes and their corresponding PVA nodes. The second level WSN is realized by the CC2530 based ZigBee network for multi-hop communication among PVA nodes and the sink node. The PVM nodes are used to monitor the PVM working voltage and backplane temperature, and they send the acquired data to their PVA node via the nRF24L01 based first level WSN. The PVA nodes are used to monitor the array voltage, PV string current and environment irradiance, and they send the acquired and received data to the DMC via the ZigBee based second level WSN. The DMC is designed using the MATLAB GUIDE and MySQL database. Laboratory experiment results show that the system can effectively acquire, display, store and manage the operating and environment parameters of PVA in real time.

  9. Advanced Detection Technology of Trace-level Borate for SG Leakage Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seban; Kang, Dukwon; Kim, Seungil; Kim, Hyunki; Heo, Jun; Sung, Jinhyun [Radiation Eng. Center, Shihung (Korea, Republic of); Lee, Dongbum [Academic Support Dept., Seoul (Korea, Republic of)

    2013-05-15

    Many studies have been reported for monitoring technology of steam generator, however, all of these methods have their own limitations. The leakage monitoring technology of steam generator of PWR has also got a limit due to the adoption of specific radionuclides (N-16, Ar-41, H-3, Xe, etc.) generated by nuclear fission, which are available only when reactor output is 20% or more. Most of domestic NPPs apply the N-16 technique for monitoring tube leakage but it has some problem that it is difficult to calculate the leakage rate because neutron flux are not completely formed during low power operation. For example, tube leakage of steam generator occurred in the Uljin nuclear power plant in 2002 during coast down operation for periodic plant maintenance. This plant could not prevent a rupture accident in advance because N-16 method is not possible the leak monitoring less than 20% reactor power. The development of excellent alternative monitoring technology that can monitor the real-time leakage is required under a variety of operating conditions like start-up and abnormal conditions of NPPs. This study was performed to lay a foundation in monitoring the leakage of steam generator coping with the lower output and low power operational condition using trace level of boron which is non-radioactive nuclide to inject control neutron injection. In this study, non-radioactive nuclide boron ion, which existed in the secondary system water, as leakage monitoring indicator was investigated for the separation of complex cation and anion phase. Borate was detected by using borate concentrator column coupled with the ion-exclusion column analytical column, revealing the problem of overlapped peak between fluoride and boron ions. Meanwhile, ion-exchange column could confirm the possibility as a leakage monitoring indicator of steam generator, despite the peak of glycolic acid salts was slightly overlapped. It will be needed for further research regarding the selectivity of the

  10. Advanced Detection Technology of Trace-level Borate for SG Leakage Monitoring

    International Nuclear Information System (INIS)

    Lee, Seban; Kang, Dukwon; Kim, Seungil; Kim, Hyunki; Heo, Jun; Sung, Jinhyun; Lee, Dongbum

    2013-01-01

    Many studies have been reported for monitoring technology of steam generator, however, all of these methods have their own limitations. The leakage monitoring technology of steam generator of PWR has also got a limit due to the adoption of specific radionuclides (N-16, Ar-41, H-3, Xe, etc.) generated by nuclear fission, which are available only when reactor output is 20% or more. Most of domestic NPPs apply the N-16 technique for monitoring tube leakage but it has some problem that it is difficult to calculate the leakage rate because neutron flux are not completely formed during low power operation. For example, tube leakage of steam generator occurred in the Uljin nuclear power plant in 2002 during coast down operation for periodic plant maintenance. This plant could not prevent a rupture accident in advance because N-16 method is not possible the leak monitoring less than 20% reactor power. The development of excellent alternative monitoring technology that can monitor the real-time leakage is required under a variety of operating conditions like start-up and abnormal conditions of NPPs. This study was performed to lay a foundation in monitoring the leakage of steam generator coping with the lower output and low power operational condition using trace level of boron which is non-radioactive nuclide to inject control neutron injection. In this study, non-radioactive nuclide boron ion, which existed in the secondary system water, as leakage monitoring indicator was investigated for the separation of complex cation and anion phase. Borate was detected by using borate concentrator column coupled with the ion-exclusion column analytical column, revealing the problem of overlapped peak between fluoride and boron ions. Meanwhile, ion-exchange column could confirm the possibility as a leakage monitoring indicator of steam generator, despite the peak of glycolic acid salts was slightly overlapped. It will be needed for further research regarding the selectivity of the

  11. Multi-phase flow monitoring with electrical impedance tomography using level set based method

    International Nuclear Information System (INIS)

    Liu, Dong; Khambampati, Anil Kumar; Kim, Sin; Kim, Kyung Youn

    2015-01-01

    Highlights: • LSM has been used for shape reconstruction to monitor multi-phase flow using EIT. • Multi-phase level set model for conductivity is represented by two level set functions. • LSM handles topological merging and breaking naturally during evolution process. • To reduce the computational time, a narrowband technique was applied. • Use of narrowband and optimization approach results in efficient and fast method. - Abstract: In this paper, a level set-based reconstruction scheme is applied to multi-phase flow monitoring using electrical impedance tomography (EIT). The proposed scheme involves applying a narrowband level set method to solve the inverse problem of finding the interface between the regions having different conductivity values. The multi-phase level set model for the conductivity distribution inside the domain is represented by two level set functions. The key principle of the level set-based method is to implicitly represent the shape of interface as the zero level set of higher dimensional function and then solve a set of partial differential equations. The level set-based scheme handles topological merging and breaking naturally during the evolution process. It also offers several advantages compared to traditional pixel-based approach. Level set-based method for multi-phase flow is tested with numerical and experimental data. It is found that level set-based method has better reconstruction performance when compared to pixel-based method

  12. Applications Geiger-Muller detectors monitor the level of radioactivity in the human body

    International Nuclear Information System (INIS)

    Gunarwan Prayitno

    2008-01-01

    Nuclear technology is the technology high risk, because of an application and implementation have to support by human skill. The support facility has to complete and up to date, or modern. It means if the accident occurs in mistake have to do or delayed something, they can solved that problem. So the probability the risk of accident can be minimized. The specific problem is in the implementation nuclear technology on the human safety which is works in the radiation field or in the environment where they are working. The pointer that the problems have to design the tools monitor to monitoring the value radiation maximum was allowed. The tools monitor design is giving the information signal, if the radiation level maximum have over limit. Whereas the high and low level radiation can be just depend on the needed. (author)

  13. Microbial Monitoring from the Frontlines to Space: Department of Defense Small Business Innovation Research Technology Aboard the International Space Station

    Science.gov (United States)

    Oubre, Cherie M.; Khodadad, Christina L.; Castro, Victoria A.; Ott, C. Mark; Flint, Stephanie; Pollack, Lawrence P.; Roman, Monserrate C.

    2017-01-01

    The RAZOR (trademark) EX, a quantitative Polymerase Chain Reaction (qPCR) instrument, is a portable, ruggedized unit that was designed for the Department of Defense (DoD) with its reagent chemistries traceable to a Small Business Innovation Research (SBIR) contract beginning in 2002. The PCR instrument's primary function post 9/11 was to enable frontline soldiers and first responders to detect biological threat agents and bioterrorism activities in remote locations to include field environments. With its success for DoD, the instrument has also been employed by other governmental agencies including Department of Homeland Security (DHS). The RAZOR (Trademark) EX underwent stringent testing by the vendor, as well as through the DoD, and was certified in 2005. In addition, the RAZOR (trademark) EX passed DHS security sponsored Stakeholder Panel on Agent Detection Assays (SPADA) rigorous evaluation in 2011. The identification and quantitation of microbial pathogens is necessary both on the ground as well as during spaceflight to maintain the health of astronauts and to prevent biofouling of equipment. Currently, culture-based monitoring technology has been adequate for short-term spaceflight missions but may not be robust enough to meet the requirements for long-duration missions. During a NASA-sponsored workshop in 2011, it was determined that the more traditional culture-based method should be replaced or supplemented with more robust technologies. NASA scientists began investigating innovative molecular technologies for future space exploration and as a result, PCR was recommended. Shortly after, NASA sponsored market research in 2012 to identify and review current, commercial, cutting edge PCR technologies for potential applicability to spaceflight operations. Scientists identified and extensively evaluated three candidate technologies with the potential to function in microgravity. After a thorough voice-of-the-customer trade study and extensive functional and

  14. Energy Use and Power Levels in New Monitors and Personal Computers; TOPICAL

    International Nuclear Information System (INIS)

    Roberson, Judy A.; Homan, Gregory K.; Mahajan, Akshay; Nordman, Bruce; Webber, Carrie A.; Brown, Richard E.; McWhinney, Marla; Koomey, Jonathan G.

    2002-01-01

    Our research was conducted in support of the EPA ENERGY STAR Office Equipment program, whose goal is to reduce the amount of electricity consumed by office equipment in the U.S. The most energy-efficient models in each office equipment category are eligible for the ENERGY STAR label, which consumers can use to identify and select efficient products. As the efficiency of each category improves over time, the ENERGY STAR criteria need to be revised accordingly. The purpose of this study was to provide reliable data on the energy consumption of the newest personal computers and monitors that the EPA can use to evaluate revisions to current ENERGY STAR criteria as well as to improve the accuracy of ENERGY STAR program savings estimates. We report the results of measuring the power consumption and power management capabilities of a sample of new monitors and computers. These results will be used to improve estimates of program energy savings and carbon emission reductions, and to inform rev isions of the ENERGY STAR criteria for these products. Our sample consists of 35 monitors and 26 computers manufactured between July 2000 and October 2001; it includes cathode ray tube (CRT) and liquid crystal display (LCD) monitors, Macintosh and Intel-architecture computers, desktop and laptop computers, and integrated computer systems, in which power consumption of the computer and monitor cannot be measured separately. For each machine we measured power consumption when off, on, and in each low-power level. We identify trends in and opportunities to reduce power consumption in new personal computers and monitors. Our results include a trend among monitor manufacturers to provide a single very low low-power level, well below the current ENERGY STAR criteria for sleep power consumption. These very low sleep power results mean that energy consumed when monitors are off or in active use has become more important in terms of contribution to the overall unit energy consumption (UEC

  15. Dynamic monitoring of weight data at the pen vs at the individual level

    DEFF Research Database (Denmark)

    Jensen, Dan; Toft, Nils; Kristensen, A. R. K.

    recorded weight data from finisher pigs. Data are collected at insertion and at the exit of the first pigs in the pen, and in few pens, the weight is recorded weekly. Dynamic linear models are fitted on the weight data, at the pig level (univariate), at the double pen level using averaged weight...... (univariate) and using individual pig values as parameters in a hierarchical (multivariate) model including section, double pen, and individual level. Variance components of the different models are estimated using the Expectation Maximization algorithm. The difference of information obtained...... at the individual vs pen level is thereafter assessed. Whereas weight data is usually monitored after a batch is being sent to the slaughter house, this method provides weekly updating of the data. Perspectives of application include dynamic monitoring of weight data in relation to events such as diarrhoea, tail...

  16. Dynamic monitoring of weight data at the pen vs at the individual level

    DEFF Research Database (Denmark)

    Jensen, Dan Børge; Toft, Nils; Kristensen, Anders Ringgaard

    recorded weight data from finisher pigs. Data are collected at insertion and at the exit of the first pigs in the pen, and in few pens, the weight is recorded weekly. Dynamic linear models are fitted on the weight data, at the pig level (univariate), at the double pen level using averaged weight...... (univariate) and using individual pig values as parameters in a hierarchical (multivariate) model including section, double pen, and individual level. Variance components of the different models are estimated using the Expectation Maximization algorithm. The difference of information obtained...... at the individual vs. pen level is thereafter assessed. Whereas weight data is usually monitored after a batch is being sent to the slaughter house, this method provides with weekly updating of the data. Perspectives of application include dynamic monitoring of weight data in relation to events such as diarrhoea...

  17. Operational intervention levels and related requirements on radiation monitoring during pre-release / release phase of an accident

    International Nuclear Information System (INIS)

    Carny, P.; Cabanekova, H

    2003-01-01

    In this paper authors discusses required outputs of emergency radiological monitoring in various phases of an accident and rationale of these requirements. In various phases of an accident various intervention levels are important and consequently various radiological quantities should be preferably measured. Distinguished tasks or aims of monitoring in different phases of accident have strong influence on methods of monitoring, instrumentation and capabilities of monitoring groups. Required tasks and outputs of monitoring are discussed

  18. First retrieval of hourly atmospheric radionuclides just after the Fukushima accident by analyzing filter-tapes of operational air pollution monitoring stations.

    Science.gov (United States)

    Tsuruta, Haruo; Oura, Yasuji; Ebihara, Mitsuru; Ohara, Toshimasa; Nakajima, Teruyuki

    2014-10-22

    No observed data have been found in the Fukushima Prefecture (FP) for the time-series of atmospheric radionuclides concentrations just after the Fukushima Daiichi Nuclear Power Plant (FD1NPP) accident. Accordingly, current estimates of internal radiation doses from inhalation, and atmospheric radionuclide concentrations by atmospheric transport models are highly uncertain. Here, we present a new method for retrieving the hourly atmospheric (137)Cs concentrations by measuring the radioactivity of suspended particulate matter (SPM) collected on filter tapes in SPM monitors which were operated even after the accident. This new dataset focused on the period of March 12-23, 2011 just after the accident, when massive radioactive materials were released from the FD1NPP to the atmosphere. Overall, 40 sites of the more than 400 sites in the air quality monitoring stations in eastern Japan were studied. For the first time, we show the spatio-temporal variation of atmospheric (137)Cs concentrations in the FP and the Tokyo Metropolitan Area (TMA) located more than 170 km southwest of the FD1NPP. The comprehensive dataset revealed how the polluted air masses were transported to the FP and TMA, and can be used to re-evaluate internal exposure, time-series radionuclides release rates, and atmospheric transport models.

  19. La mappa acustica dinamica di Milano da un numero limitato di punti di monitoraggio. Primi risultati - Milan dynamic noise mapping from few monitoring stations. First results

    Directory of Open Access Journals (Sweden)

    Giovanni Zambon

    2016-10-01

    Full Text Available Il questa memoria sono riportati i primi risultati del progetto Dynamap relativi all’area pilota di Milano. Il progetto sviluppa un approccio alla rappresentazione del rumore derivante da traffico stradale che consenta una mappatura acustica dinamica attraverso la scalatura di mappe precalcolate mediante un collegamento diretto con un numero limitato di stazioni di monitoraggio. La possibilità di controllare la mappa acustica di una rete stradale estesa mediante pochi punti di controllo si attua mediante una necessaria aggregazione degli archi stradali in gruppi omogenei. ------ This memory reports the first results of Dynamap project related to the Milan pilot area. The project develops an approach to represent road traffic noise with the outcome of a dynamic noise mapping achieved through the scaling of precalculated maps; scaling is based upon a direct connection to a limited number of noise monitoring stations. The possibility of controlling the acoustic map of an extended road network by means of a few monitoring sites is implemented through a preliminary aggregation of road stretches into homogeneous groups.

  20. First retrieval of hourly atmospheric radionuclides just after the Fukushima accident by analyzing filter-tapes of operational air pollution monitoring stations

    Science.gov (United States)

    Tsuruta, Haruo; Oura, Yasuji; Ebihara, Mitsuru; Ohara, Toshimasa; Nakajima, Teruyuki

    2014-01-01

    No observed data have been found in the Fukushima Prefecture (FP) for the time-series of atmospheric radionuclides concentrations just after the Fukushima Daiichi Nuclear Power Plant (FD1NPP) accident. Accordingly, current estimates of internal radiation doses from inhalation, and atmospheric radionuclide concentrations by atmospheric transport models are highly uncertain. Here, we present a new method for retrieving the hourly atmospheric 137Cs concentrations by measuring the radioactivity of suspended particulate matter (SPM) collected on filter tapes in SPM monitors which were operated even after the accident. This new dataset focused on the period of March 12–23, 2011 just after the accident, when massive radioactive materials were released from the FD1NPP to the atmosphere. Overall, 40 sites of the more than 400 sites in the air quality monitoring stations in eastern Japan were studied. For the first time, we show the spatio-temporal variation of atmospheric 137Cs concentrations in the FP and the Tokyo Metropolitan Area (TMA) located more than 170 km southwest of the FD1NPP. The comprehensive dataset revealed how the polluted air masses were transported to the FP and TMA, and can be used to re-evaluate internal exposure, time-series radionuclides release rates, and atmospheric transport models. PMID:25335435

  1. Power levels in office equipment: Measurements of new monitors and personal computers

    International Nuclear Information System (INIS)

    Roberson, Judy A.; Brown, Richard E.; Nordman, Bruce; Webber, Carrie A.; Homan, Gregory H.; Mahajan, Akshay; McWhinney, Marla; Koomey, Jonathan G.

    2002-01-01

    Electronic office equipment has proliferated rapidly over the last twenty years and is projected to continue growing in the future. Efforts to reduce the growth in office equipment energy use have focused on power management to reduce power consumption of electronic devices when not being used for their primary purpose. The EPA ENERGY STAR[registered trademark] program has been instrumental in gaining widespread support for power management in office equipment, and accurate information about the energy used by office equipment in all power levels is important to improving program design and evaluation. This paper presents the results of a field study conducted during 2001 to measure the power levels of new monitors and personal computers. We measured off, on, and low-power levels in about 60 units manufactured since July 2000. The paper summarizes power data collected, explores differences within the sample (e.g., between CRT and LCD monitors), and discusses some issues that arise in m etering office equipment. We also present conclusions to help improve the success of future power management programs.Our findings include a trend among monitor manufacturers to provide a single very low low-power level, and the need to standardize methods for measuring monitor on power, to more accurately estimate the annual energy consumption of office equipment, as well as actual and potential energy savings from power management

  2. Nitrogen balances at farm level as a tool to monitor effects of agri-environment policy

    NARCIS (Netherlands)

    Brouwer, F.M.

    1998-01-01

    Nitrogen balances at farm level are an important tool for monitoring the effects of agri-environmental policy in the European Union. Nitrogen surpluses, defined as the difference between input and output flows, are a pressure indicator to link agricultural activities with environmental quality

  3. Roshydromet system of environment radioactive contamination monitoring in the Arctic region of Russia

    International Nuclear Information System (INIS)

    Chelukanov, V.

    1995-01-01

    159 arctic hydrometerological stations take measurements of gamma radiation. 51 stations monitor the density of atmospheric radioactive fallout and 12 stations monitor the concentration of aerosols. 13 hydrological stations sited in the mouths of main Arctic Ocean rivers take water samples. Regional laboratories carry out isotop analysis of samples. Information on high levels of a radioactivity measured at the monitoring stations, as well as information on abnormal radioactivity from regional laboratories are transmitted to the Information Centers on the monitoring system (Moscow and Obnisk) by cable. 2 figs., 1 tab

  4. Water level monitoring using radar remote sensing data: Application to Lake Kivu, central Africa

    Science.gov (United States)

    Munyaneza, Omar; Wali, Umaru G.; Uhlenbrook, Stefan; Maskey, Shreedhar; Mlotha, McArd J.

    Satellite radar altimetry measures the time required for a pulse to travel from the satellite antenna to the earth’s surface and back to the satellite receiver. Altimetry on inland lakes generally shows some deviation from in situ level measurements. The deviation is attributed to the geographically varying corrections applied to account for atmospheric effects on radar waves. This study was focused on verification of altimetry data for Lake Kivu (2400 km 2), a large inland lake between Rwanda and the Democratic Republic of Congo (DRC) and estimating the lake water levels using bathymetric data combined with satellite images. Altimetry data obtained from ENVISAT and ERS-2 satellite missions were compared with water level data from gauging stations for Lake Kivu. Gauge data for Lake Kivu were collected from the stations ELECTROGAZ and Rusizi. ENVISAT and ERS-2 data sets for Lake Kivu are in good agreement with gauge data having R2 of 0.86 and 0.77, respectively. A combination of the two data sets improved the coefficient of determination to 95% due to the improved temporal resolution of the data sets. The calculated standard deviation for Lake Kivu water levels was 0.642 m and 0.701 m, for ENVISAT and ERS-2 measurements, respectively. The elevation-surface area characteristics derived from bathymetric data in combination with satellite images were used to estimate the lake level gauge. Consequently, the water level of Lake Kivu could be estimated with an RMSE of 0.294 m and an accuracy of ±0.58 m. In situations where gauges become malfunctioning or inaccessible due to damage or extreme meteorological events, the method can be used to ensure data continuity.

  5. Ogoya old copper mine as a monitoring station for various fields of earth sciences and radon anomaly observed at Tatsunokuchi

    Energy Technology Data Exchange (ETDEWEB)

    Komura, Kazuhisa; Wataguchi, Teru; Yamazaki, Seiji [Kanazawa Univ. (Japan)

    1997-02-01

    To utilize the tunnel of old Ogoya mine for measurement of low-level radioactivity, the intensity of cosmic ray have been determined at various points in the tunnel and basic data regarding radon level, wind velocity and temperature have been collected. Here, recent studies made in the underground laboratory in the tunnel were briefly outlined. The reciprocal of radon activity was found to be closely correlated with wind velocity. The mean activity was ca. 25 Bq/m{sup 3}, slightly higher than that in an ordinal house at the wind velocity of 0.4 m/sec and it was highest in the conditions of no wind. Thus, the tunnel was found to be suitable for the measurement of low-level radioactivity. Then, the effects of radon on the background level for the Ge-detector set in the underground laboratory were investigated and an attempt for their elimination was made using nitrogen gas. The peak counting rates of {sup 214}Pb and {sup 214}Bi, both of which are daughter nuclides of radon were remarkably reduced by introducing the gas. Further, the radon level of the atmosphere upon the ground was determined using a radon detector with electrostatic trap aiming to catch the abnormality in radon level, which is regarded as an omen of earthquake. Thus, it was suggested that the radon anomaly observed in Tatsunokuchi during from Aug. 31 to Sep. 12 might be associated with the earthquake with a magnitude of 3.2 occurred 9 Km apart from the town on September 10. (M,N.)

  6. Groundwater level monitoring sampling and analysis plan for environmental monitoring in Waste Area Grouping 6 at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-01

    This Sampling and Analysis Plan addresses groundwater level monitoring activities that will be conducted in support of the Environmental Monitoring Plan for Waste Area Grouping (WAG) 6. WAG 6 is a shallow-burial land disposal facility for low-level radioactive waste at the Oak Ridge National Laboratory, a research facility owned by the US Department of Energy and managed by Martin Marietta Energy Systems, Inc. Groundwater level monitoring will be conducted at 129 sites within the WAG. All of the sites will be manually monitored on a semiannual basis. Forty-five of the 128 wells, plus one site in White Oak Lake, will also be equipped with automatic water level monitoring equipment. The 46 sites are divided into three groups. One group will be equipped for continuous monitoring of water level, conductivity, and temperature. The other two groups will be equipped for continuous monitoring of water level only. The equipment will be rotated between the two groups. The data collected from the water level monitoring will be used to support determination of the contaminant flux at WAG 6.

  7. Groundwater level monitoring sampling and analysis plan for environmental monitoring in Waste Area Grouping 6 at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1994-04-01

    This Sampling and Analysis Plan addresses groundwater level monitoring activities that will be conducted in support of the Environmental Monitoring Plan for Waste Area Grouping (WAG) 6. WAG 6 is a shallow-burial land disposal facility for low-level radioactive waste at the Oak Ridge National Laboratory, a research facility owned by the US Department of Energy and managed by Martin Marietta Energy Systems, Inc. Groundwater level monitoring will be conducted at 129 sites within the WAG. All of the sites will be manually monitored on a semiannual basis. Forty-five of the 128 wells, plus one site in White Oak Lake, will also be equipped with automatic water level monitoring equipment. The 46 sites are divided into three groups. One group will be equipped for continuous monitoring of water level, conductivity, and temperature. The other two groups will be equipped for continuous monitoring of water level only. The equipment will be rotated between the two groups. The data collected from the water level monitoring will be used to support determination of the contaminant flux at WAG 6

  8. Performance Assessment Monitoring Plan for the Hanford Site Low-Level Burial Grounds

    International Nuclear Information System (INIS)

    2006-01-01

    The U.S. Department of Energy Order 435.1, Radioactive Waste Management, requires a disposal authorization statement authorizing operation (or continued operation) for low-level waste disposal facilities. In fulfillment of these requirements, a disposal authorization statement was issued on October 25, 1999, authorizing the Hanford Site to transfer, receive, possess, and dispose of low-level radioactive waste at the 200 East Area burial grounds and the 200 West Area burial grounds. One of the conditions is that monitoring plans for the 200 East Area and 200 West Area low-level burial grounds be written and approved by the Richland Operations Office. As a result of a record of decision for the Hanford Site Solid Waste Program and acceptance of the Hanford Site Solid Waste Environmental Impact Statement, the use of the low-level burial ground (LLBG) as a disposal facility for low-level and mixed low-level wastes has been restricted to lined trenches and the Navy reactor-compartment trench only. Hence, as of July 2004, only the two lined trenches in burial ground 218-W-5 (trenches 31 and 34, see Appendix A) and the Navy reactor-compartment trench in burial ground 218 E 12B (trench 94) are allowed to receive waste. When the two lined trenches are filled, the LLBG will cease to operate except for reactor compartment disposal at trench 94. Remaining operational lifetime of the LLBG is dependent on waste volume disposal rates. Existing programs for air sampling and analyses and subsidence monitoring are currently adequate for performance assessment at the LLBG. The waste disposal authorization for the Hanford Site is based (in part) on the post-closure performance assessments for the LLBG. In order to maintain a useful link between operational monitoring (e.g., Resource Conservation and Recovery Act [RCRA], Comprehensive Environmental Response, Compensation, and Liability Act, and State Waste Discharge Permits), constituents, monitoring frequencies, and boundaries require

  9. A research on the environmental impact on nearby waters range at low-level radioactive waste water drain from the Dayawan nuclear power station

    International Nuclear Information System (INIS)

    Zhang Chunling; Xu Zitu; Xiao Zhang.

    1987-01-01

    The possible influence of the low-level radioactive waste water drain from the Dayawan nuclear power station upon nearby waters range is discussed. The contents of the article contains the numerical simulation on tidal currents and pollutant diffusion, the calculation of concentration distribution of radioactive contaminants in the water area and of polluted field, and the criterion on radioactive contaminant influence on nearby residents and aquatic biologicals. The result shows that when the Dayawan nuclear power station is on normal operation and after the low-level radioactive waste water has been drained off into the sea, the radioactive concentration is even lower than the natural background radiation just out-side the area of about 4 km 2 round the water outlet. As a result, it won't cause any danger to the water environment. Due to the fact that the concentration of the low-level radioactive waste water from the nuclear power station fully accords with the national standard GB4792-84 and the sea water quality sandard GBH2, 3-82. It is no harm to either residents and aquatic biologicals or ecological balance

  10. The Architecture of the CMS Level-1 Trigger Control and Monitoring System

    CERN Document Server

    Magrans de Abril, Marc; Hammer, Josef; Hartl, Christian; Xie, Zhen

    2011-01-01

    The architecture of the Level-1 Trigger Control and Monitoring system for the CMS experiment is presented. This system has been installed and commissioned on the trigger online computers and is currently used for data taking at the LHC. This is a medium-size distributed system that runs over 40 PCs and 200 processes that control about 4000 electronic boards. It has been designed to handle the trigger configuration and monitoring during data taking as well as all communications with the main run control of CMS. Furthermore its design has foreseen the provision of the software infrastructure for detailed testing of the trigger system during beam down time.

  11. Spatially monitoring oxygen level in 3D microfabricated cell culture systems using optical oxygen sensing beads

    OpenAIRE

    Wang, Lin; Acosta, Miguel A.; Leach, Jennie B.; Carrier, Rebecca L.

    2013-01-01

    Capability of measuring and monitoring local oxygen concentration at the single cell level (tens of microns scale) is often desirable but difficult to achieve in cell culture. In this study, biocompatible oxygen sensing beads were prepared and tested for their potential for real-time monitoring and mapping of local oxygen concentration in 3D micro-patterned cell culture systems. Each oxygen sensing bead is composed of a silica core loaded with both an oxygen sensitive Ru(Ph2phen3)Cl2 dye and ...

  12. Integrated Coastal Observation Network (ICON) for real-time monitoring of sea-level, sea-state, and surface-meteorological data

    Digital Repository Service at National Institute of Oceanography (India)

    Desai, R.G.P.; Joseph, A.; Agarvadekar, Y.; Mehra, P.; VijayKumar, K.; Luis, R.

    ). Real-time reporting capability of ICON yields several benefits, such as (i) remote monitoring of proper working condition of individual stations; (ii) implementation of repair/maintenance in the shortest possible time, thereby minimizing break...

  13. Fire Stations

    Data.gov (United States)

    Department of Homeland Security — Fire Stations in the United States Any location where fire fighters are stationed or based out of, or where equipment that such personnel use in carrying out their...

  14. National Seismic Station

    International Nuclear Information System (INIS)

    Stokes, P.A.

    1982-06-01

    The National Seismic Station was developed to meet the needs of regional or worldwide seismic monitoring of underground nuclear explosions to verify compliance with a nuclear test ban treaty. The Station acquires broadband seismic data and transmits it via satellite to a data center. It is capable of unattended operation for periods of at least a year, and will detect any tampering that could result in the transmission of unauthentic seismic data

  15. Manage habitat, monitor species [Chapter 10

    Science.gov (United States)

    Michael K. Schwartz; Jamie S. Sanderlin; William M. Block

    2015-01-01

    Monitoring is the collection of data over time. We monitor many things: temperatures at local weather stations, daily changes in sea level along the coastline, annual prevalence of specific diseases, sunspot cycles, unemployment rates, inflation, commodity futures-the list is virtually endless. In wildlife biology, we also conduct a lot of monitoring, most commonly...

  16. SWATCH Common software for controlling and monitoring the upgraded CMS Level-1 trigger

    CERN Document Server

    Lazaridis, Christos; Bunkowski, Karol; Codispoti, Giuseppe; Dirkx, Glenn; Ghabrous Larrea, Carlos; Lingemann, Joschka; Kreczko, Lukasz; Thea, Alessandro; Williams, Tom

    2017-01-01

    The Large Hadron Collider at CERN restarted in 2015 with a higher centre-of-mass energy of 13 TeV. The instantaneous luminosity is expected to increase significantly in the coming years. An upgraded Level-1 trigger system is being deployed in the CMS experiment in order to maintain the same efficiencies for searches and precision measurements as those achieved in the previous run. This system must be controlled and monitored coherently through software, with high operational efficiency.The legacy system is composed of approximately 4000 data processor boards, of several custom application-specific designs. These boards are organised into several subsystems; each subsystem receives data from different detector systems (calorimeters, barrel/endcap muon detectors), or with differing granularity. These boards have been controlled and monitored by a medium-sized distributed system of over 40 computers and 200 processes. Only a small fraction of the control and monitoring software was common between the different s...

  17. Microbial Monitoring from the Frontlines to Space: A Successful Validation of a Department of Defense (DoD) Funded Small Business Innovation Research (SBIR) Technology on Board the International Space Station (ISS)

    Science.gov (United States)

    Oubre, Cherie; Khodadad, Christina; Castro, Victoria; Ott, Mark; Pollack, Lawrence; Roman, Monsi

    2017-01-01

    The RAZOR EX (Registered Trademark) PCR unit was initially developed by the DoD as part of an SBIR project to detect and identify biothreats during field deployment. The system was evaluated by NASA as a commercial technology for future microbial monitoring requirements and has been successfully demonstrated in microgravity on-board the International Space Station.

  18. Wind turbine power stations

    International Nuclear Information System (INIS)

    Anon.

    1992-11-01

    The Countryside Council for Wales (CCW's) policy on wind turbine power stations needs to be read in the context of CCW's document Energy:Policy and perspectives for the Welsh countryside. This identifies four levels of action aimed at reducing emission of gases which contribute towards the risk of global warming and gases which cause acid deposition. These are: the need for investment in energy efficiency; the need for investment in conventional power generation in order to meet the highest environmental standards; the need for investment in renewable energy; and the need to use land use transportation policies and decisions to ensure energy efficiency and energy conservation. CCW views wind turbine power stations, along with other renewable energy systems, within this framework. CCW's policy is to welcome the exploitation of renewable energy sources as an element in a complete and environmentally sensitive energy policy, subject to the Environmental Assessment of individual schemes and monitoring of the long-term impact of the various technologies involved. (Author)

  19. A detection-level hazardous waste ground-water monitoring compliance plan for the 200 areas low-level burial grounds and retrievable storage units

    International Nuclear Information System (INIS)

    1987-02-01

    This plan defines the actions needed to achieve detection-level monitoring compliance at the Hanford Site 200 Areas Low-Level Burial Grounds (LLBG) in accordance with the Resource Conservation and Recovery Act (RCRA). Compliance will be achieved through characterization of the hydrogeology and monitoring of the ground water beneath the LLBG located in the Hanford Site 200 Areas. 13 refs., 20 figs

  20. 162.5 MHz digital low-level radio frequency control monitoring system design and implementation

    International Nuclear Information System (INIS)

    Zhang Ruifeng; Wang Xianwu; Xu Zhe; Yi Xiaoping

    2014-01-01

    162.5 MHz high-frequency low-level control system self-developed by Institute of Modern Physics for ADS project took digital technology. All parameters' reading and writing, including loop parameter setting, open and close-loop operation, and condition monitoring, were achieved through the monitoring system. The system used lightweight client-server working mode that client running in the PC sent command data, server running on high-frequency digital low level system responded instructions to complete parameter monitoring and control. The system consisted of three parts. Firstly, server hardware system was constructed based on Atera Stratix Ⅲ family of field-programmable gate array (FPGA) development board. Secondly, the server software system was designed based on Micro C/OS Ⅱ real-time operating systems and lightweight TCP/IP protocol stack, and finally a client PC program was designed based on MFC. After a long test, it was indicated that the monitoring system works properly and stably. TCP sends and receives throughput reached 11.931038 Mbps and 8.117624 Mbps. (authors)

  1. Allaying public concern regarding CO{sub 2} geological sequestration through the development of automated stations for the continuous geochemical monitoring of gases in the near surface environment

    Energy Technology Data Exchange (ETDEWEB)

    Annunziatellis, A.; Beaubien, S.E.; Ciotoli, G.; Lombardi, S. [La Sapienza Univ., Rome (Italy). Dept. of Earth Sciences

    2005-07-01

    Several carbon dioxide (CO{sub 2}) enhanced oil recovery projects conducted in North America have demonstrated that the deep, onshore geological sequestration of anthropogenic CO{sub 2} is technically feasible. However, the technology has yet to be proven to regulators and the general public. It must be demonstrated that carbon sequestration will result in the long-term isolation of the injected CO{sub 2} and that there is no health risk for local residents due to the leakage of CO{sub 2} at surface. It was suggested that in order to alleviate these concerns, low-cost, early warning systems should be installed to monitor gas compositions and concentrations in the soil gas and groundwater. Doing so, would trigger a warning if any increased concentrations of CO{sub 2} or other associated gases were noted in these phases, and allow for early examination of the cause of the anomalous value. In addition, since gas flow is typically along natural faults or abandoned bore holes, installation of monitoring stations around these higher risk sites would help maximize efficiency while minimizing costs. In this study, gas permeable tubing was used to sample soil gas or gases dissolved in groundwater via diffusion. In the case of equilibration with a gas phase the gas concentration within the tubing will eventually match that of the surrounding environment, whereas in the aqueous phase the internal volume of the tube will represent a head space where equilibrium concentrations will be governed by Henry's Constant. CO{sub 2}, hydrogen and hydrogen sulphide from either soil-gas or groundwater were analyzed with low cost infra-red electrochemical detectors. The data was processed with an integrated computer and the results were sent automatically via modem to a central laboratory. The prototype was installed in the San Vittorino Plain in central Italy where it has collected over 5 months of continuous CO{sub 2} data in an area susceptible to sinkhole formation caused by the

  2. Proceedings of the international symposium on environmental monitoring and dose estimation of residents after accident of TEPCO's Fukushima Daiichi Nuclear Power Stations

    International Nuclear Information System (INIS)

    Takahashi, Sentaro; Yamana, Hajimu; Takahashi, Tomoyuki; Takamiya, Koichi; Fukutani, Satoshi; Sato, Nobuhiro; Nakatani, Maki

    2013-02-01

    In March 2011, a massive earthquake and the resulting tsunami struck the Tohoku area in Japan, causing serious damages to TEPCO's Fukushima Daiichi nuclear plant and the release of a significant quantity of radionuclides into the surrounding environment. This accident underlined the necessity of establishing new and comprehensive scientific research for promoting safety in nuclear technology. With this aim, the Kyoto University Research Reactor Institute (KURRI) developed a new research program called the “KUR Research Program for Scientific Basis of Nuclear Safety” from this year. In this program, we are planning to hold an annual series of international symposiums along with many other research activities. The first in this series of symposiums, entitled “The International Symposium on Environmental Monitoring and Dose Estimation of Residents after Accident of TEPCO's Fukushima Daiichi Nuclear Power Station,” deals with the radiological effect of the March 2011 accident in Fukushima Daiichi NPP on the public. The purpose of this symposium is to collate data on environmental radioactivity anadiation dose in residents, discuss and verify these data, and clarify the actual situation of environmental contamination anesultant radiation exposed to the residents. We believe that an accurate estimation of the radiation dose is quite essential for planning for the healthy life and mental contentment of the residents, and we hope that many researchers who are studying the radiological effects of the accident will join us for these purposes. The environmental monitoring data are important for the dose assessment for residents. However, the monitoring data in the early stage are not sufficient for dose assessment, particularly near the NPP site, because of the confusion and blackout caused by the earthquake. However, many researchers and organizations in Japan and other countries have independently carried out radiation monitoring. We believe that the publication and

  3. 40 CFR 75.81 - Monitoring of Hg mass emissions and heat input at the unit level.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Monitoring of Hg mass emissions and... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTINUOUS EMISSION MONITORING Hg Mass Emission Provisions § 75.81 Monitoring of Hg mass emissions and heat input at the unit level. The owner or operator of the...

  4. CRIT-LINE: a noninvasive tool to monitor hemoglobin levels in pediatric hemodialysis patients.

    Science.gov (United States)

    Garro, Rouba; Sutherland, Scott; Bayes, Liz; Alexander, Steven; Wong, Cynthia

    2015-06-01

    The national average for achieving the KDOQI-recommended hemoglobin (Hgb) target level of 11-12 g/dL is low with the current anemia management protocol of measuring Hgb levels every 2-4 weeks to guide intervention. The objective of this study was to correlate initial Hgb readings from the CRIT-LINE monitor with actual serum Hgb levels in pediatric patients on hemodialysis (HD). Data were collected from pediatric HD patients who had Hgb tests ordered for routine and/or clinical reasons. Hgb concentrations were read with the CRIT-LINE after 0.5 or 1 L of blood had been processed by HD in patients with a body weight of ≤20 or >20 kg, respectively. Ultrafiltration was kept at a minimum until the CRIT-LINE Hgb was read. In total, 217 Hgb readings from 23 HD patients were analyzed. Results showed a statistically significant correlation between CRIT-LINE readings and laboratory Hgb measurements (r = 0.94, p < 0.0001) using Pearson correlation coefficients for well-distributed data. The mean Hgb levels measured by CRIT-LINE and the laboratory were 11.12 ± 1.63 and 11.31 ± 1.69 g/dL, respectively. The CRIT-LINE monitor is an accurate instrument for monitoring Hgb levels in HD patients. Further studies will be needed to evaluate whether using CRIT-LINE Hgb levels to guide anemia management will improve the percentage of children with Hgb levels within target.

  5. The relative influence of the anthropogenic air pollutants on the atmospheric turbidity factors measured at an urban monitoring station

    International Nuclear Information System (INIS)

    Elminir, Hamdy K.; Hamid, R.H.; El-Hussainy, F.; Ghitas, Ahmed E.; Beheary, M.M.; Abdel-Moneim, Khaled M.

    2006-01-01

    This work is based on simultaneous measurements of direct solar radiation along with other chemical measurements, with the objective of investigating the diurnal and seasonal variations of atmospheric turbidity factors (i.e., Linke's factor, Angstroem's coefficient, and aerosol optical depth). Relationships between atmospheric turbidity factors, expressing the solar radiation extinction, and anthropogenic air pollutants were also evaluated. The frequency of occurrence of the individual indices has been established to describe the sky conditions. The preliminary results obtained indicate high variability of aerosol loading, leading to high turbidity for most of the year. Annual averages of 0.2 and 6 with standard deviations of 0.096 and 0.98 were found for Angstroem and Linke turbidities, respectively. On the base of the frequency of occurrence, it has been found that over 50% of the dataset are around 0.25 and 6.3 for Angstroem and Linke turbidities, respectively. On average, the month of September experienced the highest turbidity, while December experienced the lowest. A possible reason for this is that the vertical distribution of the aerosol particles moves up in September due to the extent of the Sudan monsoon trough. We also note that spring values of the turbidity factors are closer to summer values, whereas the pronounced difference between the summer values in comparison with the winter values may be attributed to relatively greater difference in the water vapor level in the atmosphere

  6. One Year of Monthly N and O Isotope Measurements in Nitrate from 18 Streamwater Monitoring Stations Within the Predominantly Pastoral Upper Manawatu Catchment, New Zealand

    Science.gov (United States)

    Baisden, W. T.; Douence, C.

    2010-12-01

    New Zealand's intensive pastoral agricultural systems have a significant impact on water quality due to nitrogen loading in rivers. A research programme has been designed to develop indicators of the sources and denitrification losses of nitrate in streamwater. This work describes the results of one year of monthly measurements at ~18 monitoring locations in the 1260 square km upper Manawatu River catchment. The catchment was chosen for study because it is among the most pastoral catchments in New Zealand, with little non-pastoral agriculture and limited forest area outside of the Tararua mountain range on the west side of the catchment. The use of N and O isotope ratios in nitrate has considerable potential to elucidate the sources and fate of nitrate with greater precision than in most other nations due to the lack of nitrate in atmospheric deposition and the lack of nitrates used as fertilizer. We measured N and O isotope ratios in nitrate plus nitrite using cadmium and azide chemical denitrification method, and refer to the results as nitrate for brevity due to low nitrite concentrations. When examined as annual averages at each monitoring site, we found the lowest N and O isotope ratios in our only site draining native forest. All agricultural monitoring sites sit approximately on a 1:1 line, enriched in N-15 and O-18 by 2-6 per mil relative to the native forest subcatchment. The three main effluent point sources in the catchment demonstrated unexpected variability in isotope ratios. Two modern sewage treatment ponds had N and O isotope ratios close to those found in agricultural catchments, while a closed meat freezing factory effluent pond had isotope ratios strongly enriched in N-15 and O-18. The lack of summer low flows during monitoring period, combined with the variability in isotope ratios from point source, appeared to be responsible for our inability to clearly detect the effect of point sources in the isotope data from stations upstream and

  7. Monitoring the ground water level change during the pump test by using the Electric resistivity tomography

    Science.gov (United States)

    Hsu, H.; Chang, P. Y.; Yao, H. J.

    2017-12-01

    For hydrodynamics study of the unconfined aquifer in gravel formation, a pumping test was established to estimate the hydraulic conductivity in the midstream of Zhoushui River in Taiwan. The hydraulic parameters and the cone of depression could be estimated by monitoring the groundwater drawdown in an observation well which was in a short distance far from the pumping well. In this study we carried out the electric resistivity image monitoring during the whole pumping test. The electric resistivity data was measured with the surface and downhole electrodes which would produce a clear subsurface image of groundwater level through a larger distance than the distance between pumping and observation wells. The 2D electric image could also describe how a cone of depression truly created at subsurface. The continuous records could also show the change of groundwater level during the whole pumping test which could give a larger scale of the hydraulic parameters.

  8. Feasibility of estimate sediment yield in the non-sediment monitoring station area - A case study of Alishan River watershed,Taiwan

    Science.gov (United States)

    Chang, ChiaChi; Chan, HsunChuan; Jia, YaFei; Zhang, YaoXin

    2017-04-01

    Due to the steep topography, frail geology and concentrated rainfall in wet season, slope disaster occurred frequently in Taiwan. In addition, heavy rainfall induced landslides in upper watersheds. The sediment yield on the slopeland affects the sediment transport in the river. Sediment deposits on the river bed reduce the river cross section and change the flow direction. Furthermore, it generates risks to residents' lives and property in the downstream. The Taiwanese government has been devoting increasing efforts on the sedimentary management issues and on reduction in disaster occurrence. However, due to the limited information on the environmental conditions in the upper stream, it is difficult to set up the sedimentary monitoring equipment. This study used the upper stream of the Qingshuei River, the Alishan River, as a study area. In August 2009, Typhoon Morakot caused the sedimentation of midstream and downstream river courses in the Alishan River. Because there is no any sediment monitoring stations within the Alishan River watershed, the sediment yield values are hard to determine. The objective of this study is to establish a method to analyze the event-landslide sediment transport in the river on the upper watershed. This study numerically investigated the sediment transport in the Alishan River by using the KINEROS 2 model developed by the United States Department of Agriculture and the CCHE1D model developed by the National Center for Computational Hydroscience and Engineering. The simulated results represent the morphology changes in the Alishan River during the typhoon events. The results consist of a critical strategy reference for the sedimentary management for the Alishan River watershed.

  9. The significance of monitoring sex hormones levels after ovarian tissue auto-transplantation

    International Nuclear Information System (INIS)

    Wang Qiuwei; Xu Peizhen; Yu Bin; Zhou Hong

    2003-01-01

    Objective: To evaluate the significance of monitoring serum sex hormones levels after ovarian tissue auto-transplantation. Methods: Twenty-five patients with stage IV recurrent endometriosis after one or two times of conservative surgeries underwent radical surgery. Their ovarian tissue fragments were transplanted to greater omentum. Serum follicle-stimulation hormone (FSH), Luteinizing hormone (LH) and estradiol (E 2 ) levels were measured monthly since fourth month post-operatively. After E 2 was increased, based body temperature was measured and vaginal hormone cytology was examined weekly for maturation index (MI) to assess the ovulatory phase and luteal phase in those with viable ovarian tissues. Serum levels of FSH, LH and E 2 in ovulatory phase and luteal phase were determined 20 women with viable ovarian tissues for three cycles as well as in 20 normal sexually mature women and 20 operative menopausal women. Results: There were 12 cases who had increasing of E 2 at four months post operatively and 8 cases more at six months. The other 5 cases with low serum E 2 levels and high FSH and LH levels at 12 months were designated as failures. The survival rate of transplanted ovarian tissue was 80.0%. There were no significant differences of the serum FSH, LH and E 2 levels in ovulatory phase and luteal phase between women with viable grafted ovarian tissues and normal sexually mature women. Conclusion: Monitoring of sex hormones is a good means to assess the viability of the transplanted ovarian tissue fragments

  10. High water level installation of monitoring wells for underground storage tanks

    International Nuclear Information System (INIS)

    Treadway, C.

    1990-01-01

    This paper briefly describes a common monitoring well installation design for shallow ground water contamination resulting from leaky underground storage tanks. The paper describes drilling techniques used in unconsolidated Florida aquifers using hollow-stem augers. It describes methods for the prevention of heaving sands and sand-locking problems. It then goes on to describe the proper well casing placement and sealing techniques using neat cements. The proper sell screen level is also discussed to maximize the detection of floating hydrocarbons

  11. Parsimonious model for blood glucose level monitoring in type 2 diabetes patients.

    Science.gov (United States)

    Zhao, Fang; Ma, Yan Fen; Wen, Jing Xiao; DU, Yan Fang; Li, Chun Lin; Li, Guang Wei

    2014-07-01

    To establish the parsimonious model for blood glucose monitoring in patients with type 2 diabetes receiving oral hypoglycemic agent treatment. One hundred and fifty-nine adult Chinese type 2 diabetes patients were randomized to receive rapid-acting or sustained-release gliclazide therapy for 12 weeks. Their blood glucose levels were measured at 10 time points in a 24 h period before and after treatment, and the 24 h mean blood glucose levels were measured. Contribution of blood glucose levels to the mean blood glucose level and HbA1c was assessed by multiple regression analysis. The correlation coefficients of blood glucose level measured at 10 time points to the daily MBG were 0.58-0.74 and 0.59-0.79, respectively, before and after treatment (Pblood glucose levels measured at 6 of the 10 time points could explain 95% and 97% of the changes in MBG before and after treatment. The three blood glucose levels, which were measured at fasting, 2 h after breakfast and before dinner, of the 10 time points could explain 84% and 86% of the changes in MBG before and after treatment, but could only explain 36% and 26% of the changes in HbA1c before and after treatment, and they had a poorer correlation with the HbA1c than with the 24 h MBG. The blood glucose levels measured at fasting, 2 h after breakfast and before dinner truly reflected the change 24 h blood glucose level, suggesting that they are appropriate for the self-monitoring of blood glucose levels in diabetes patients receiving oral anti-diabetes therapy. Copyright © 2014 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.

  12. Performance Assessment Monitoring Plan for the Hanford Site Low-Level Waste Burial Grounds

    International Nuclear Information System (INIS)

    SONNICHSEN, J.C.

    2000-01-01

    As directed by the U.S. Department of Energy (DOE), Richland Operations Office (DOE-RL), Fluor Hanford, Inc. will implement the requirements of DOE Order 435.1, Radioactive Waste Management, as the requirements relate to the continued operation of the low-level waste disposal facilities on the Hanford Site. DOE Order 435.1 requires a disposal authorization statement authorizing operation (or continued operation) of a low-level waste disposal facility. The objective of this Order is to ensure that all DOE radioactive waste is managed in a manner that protects the environment and personnel and public health and safety. The manual (DOE Order 435.1 Manual) implementing the Order states that a disposal authorization statement shall be issued based on a review of the facility's performance assessment and composite analysis or appropriate Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) of 1980 documentation. The disposal authorization shall specify the limits and conditions on construction, design, operations, and closure of the low-level waste facility. Failure to obtain a disposal authorization statement shall result in shutdown of an operational disposal facility. In fulfillment of the requirements of DOE Order 435.1, a disposal authorization statement was issued on October 25, 1999, authorizing the Hanford Site to transfer, receive, possess, and dispose of low-level radioactive waste at the 200 East Area and the 200 West Area Low-Level Burial Grounds. The disposal authorization statement constitutes approval of the performance assessment and composite analysis, authorizes operation of the facility, and includes conditions that the disposal facility must meet. One of the conditions is that monitoring plans for the 200 East Area and 200 West Area Low-Level Burial Grounds be written and approved by the DOE-RL. The monitoring plan is to be updated and implemented within 1 year following issuance of the disposal authorization statement to

  13. Behaviour of suspended particulate matter (SPM and selected trace metals during the 2002 summer flood in the River Elbe (Germany at Magdeburg monitoring station

    Directory of Open Access Journals (Sweden)

    M. Baborowski

    2004-01-01

    Full Text Available In August 2002, in the worst flooding in more than 100 years, the River Elbe destroyed built-up areas and caused widespread erosion and the relocation of soils and river sediments. To assess the pollutants entering the water, surveys of dissolved constituents and suspended particulate matter (SPM were carried out daily during the flood at a monitoring station near Magdeburg. The sampling point is part of the network of the International Commission for the Protection of the Elbe (ICPE. The results were compared with those of previous flood studies which used the same sampling strategy. Unlike past floods, the 2002 flood was characterised by the transport of relatively fine suspended material with a low mass concentration. Owing to different input sources, the maxima of dry weight and of particle number concentration occurred at different times. Hg, Fe, Mn, Zn, Cu, Ni and Cr showed a maximum concentration concurrent with the dry weight of the SPM, whereas the maximum concentrations of As, Pb, and Cd coincided with the particle number concentration peak. The concentration of particulate matter decreased rapidly, unlike the concentrations of dissolved substances such as DOC and trace metals, as well as the values of UV extinction, all of which remained high for a longer period. Comparing the results of the 2002 flood with the winter floods in 1995, 1999 and 2000, revealed increased values of As and Pb as well as higher concentrations of dissolved compounds. Keywords: river, flood, transport, suspended particulate matter, trace metals, dissolved compounds, Elbe

  14. OLDES - an on-line dose evaluation system that can be integrated into the remote monitoring system of nuclear power stations for additional monitoring and prognostic assessment in case of major accidental activity release

    International Nuclear Information System (INIS)

    Witt, H. de; Brenk, H.D.; Kruschel, K.P.; Knaup, A.G.

    1986-01-01

    Remote monitoring systems are an inherent part of the environmental surveillance installations of most commercial LWR power plants in the FRG. The systems are designed to cover routine and accident situations. They provide meteorological data, gross effluent dose rates, and dose measurements at approximately 25 locations in the vicinity of the plant in time steps of 10 minutes. Based on such a network, an attempt has been made to develop an on-line dose evaluation system (OLDES) as a tool to aid decision making processes in case of major accidental releases. On-line, here means that the software package directly includes the measurements at the monitoring stations in order to adjust the dose computations to the measurements in time steps of 10 minutes. In this way the system yields the best possible bases, both for actual diagnosis of radiation exposure, and for dose projections. The software package uses a Gaussian puff trajectory model to simulate atmospheric dispersion and deposition of radionuclides. It includes 'cloud- and ground-shine irradiation' and allows for changing weather conditions without exceeding the limits of real time calculation. Preliminary tests of the software package revealed reasonable semioperational performance. (orig.)

  15. [The significance of enviromental and biological monitoring in workers employed in service stations after the elimitation of tetraethyl lead from gasoline].

    Science.gov (United States)

    Ghittori, S; Ferrari, M; Maestri, L; Negri, S; Zadra, P; Gremita, C; Imbriani, M

    2005-01-01

    The chemical risk in service stations may be due to toxic compounds present in fuel (particularly benzene and additives) and to the emission of exhausts and fine particulate from vehicles. Owing to the elimination of lead (Pb) from fuel and to the necessity of lowering CO emission, several oxygenated additives have been added to fuel, in particular methyl-tert-butyl-ether (MTBE), whose toxic properties are at present under investigation. The introduction of reformulated gasoline (RFG) and the use of catalytic converters (with possible release of platinum (Pt) in the environment) may have modified the risks for workers employed in service stations. The paper shows data collected from 26 subjects (divided into three specific tasks, namely: fuel dispenser, "self-service" attendant and controller, and cashier) to estimate the actual chemical risk and to compare it with the previous data taken from literature. For this purpose, besides performing the usual medical surveillance, we measured the environmental concentrations of benzene, MTBE and formaldehyde, the urinary levels of benzene metabolites S-phenylmercapturic acid (S-PMA) and t,t-muconic acid (MA) and of unmodified MTBE, and the blood concentrations of Pb and Pt for each subject. Mean values of these compounds were, respectively: 38.81 microg/m3; 174.04 microg/m3; 10.38 microg/m3; 2.36 microg/g creatinine; 96.57 microg/g creatinine; 1.41 microg/L; 7.00 microg/100 mL; 0.0738 ng/ml. The above values were much lower than the corresponding limit values reported by ACGIH and DFG. In particular, after the introduction of vapour recycle systems and the widespread use of "self-service" systems, airborne benzene concentration dropped from 300/400 microg/m3 to lower than 100 microg/m3, without noticeable increasing of exposure to formaldehyde. The disappearing of Pb from gasoline leads to a progressive lowering of its blood levels, while the possible risks due to the very low amounts of Pt released from catalytic

  16. Levels-of-processing effect on internal source monitoring in schizophrenia.

    Science.gov (United States)

    Ragland, J Daniel; McCarthy, Erin; Bilker, Warren B; Brensinger, Colleen M; Valdez, Jeffrey; Kohler, Christian; Gur, Raquel E; Gur, Ruben C

    2006-05-01

    Recognition can be normalized in schizophrenia by providing patients with semantic organizational strategies through a levels-of-processing (LOP) framework. However, patients may rely primarily on familiarity effects, making recognition less sensitive than source monitoring to the strength of the episodic memory trace. The current study investigates whether providing semantic organizational strategies can also normalize patients' internal source-monitoring performance. Sixteen clinically stable medicated patients with schizophrenia and 15 demographically matched healthy controls were asked to identify the source of remembered words following an LOP-encoding paradigm in which they alternated between processing words on a 'shallow' perceptual versus a 'deep' semantic level. A multinomial analysis provided orthogonal measures of item recognition and source discrimination, and bootstrapping generated variance to allow for parametric analyses. LOP and group effects were tested by contrasting recognition and source-monitoring parameters for words that had been encoded during deep versus shallow processing conditions. As in a previous study there were no group differences in LOP effects on recognition performance, with patients and controls benefiting equally from deep versus shallow processing. Although there were no group differences in internal source monitoring, only controls had significantly better performance for words processed during the deep encoding condition. Patient performance did not correlate with clinical symptoms or medication dose. Providing a deep processing semantic encoding strategy significantly improved patients' recognition performance only. The lack of a significant LOP effect on internal source monitoring in patients may reflect subtle problems in the relational binding of semantic information that are independent of strategic memory processes.

  17. Development and Certification of Station Development Test Objective (SDTO) Experiment # 15012-U, "Near RealTime Water Quality Monitoring Demonstration for ISS Biocides Using Colorimetric Solid Phase Extraction (CSPE)"

    Science.gov (United States)

    Gazda, Daniel B.; Nolan, Daniel J.; Rutz, Jeffrey A.; Shcultz, John R.; Siperko, Lorraine M.; Porter, Marc D,; Lipert, Robert J.; Limardo, Jose G.; McCoy, J. Torin

    2009-01-01

    Scientists and engineers from the Wyle Integrated Science and Engineering Group are working with researchers at the University of Utah and Iowa State University to develop and certify an experimental water quality monitoring kit based on Colorimetric Solid Phase Extraction (CSPE). The kit will be launched as a Station Development Test Objective (SDTO) experiment and evaluated on the International Space Station (ISS) to determine the acceptability of CSPE technology for routine inflight water quality monitoring. Iodine and silver, the biocides used in the US and Russian on-orbit water systems, will serve as test analytes for the technology evaluation. This manuscript provides an overview of the CSPE SDTO experiment and details the development and certification of the experimental water quality monitoring kit. Initial results from reagent and standard solution stability testing and environmental testing performed on the kit hardware are also reported.

  18. Intelligent low-level RF system by non-destructive beam monitoring device for cyclotrons

    Science.gov (United States)

    Sharifi Asadi Malafeh, M. S.; Ghergherehchi, M.; Afarideh, H.; Chai, J. S.; Yoon, Sang Kim

    2016-04-01

    The project of a 10 MeV PET cyclotron accelerator for medical diagnosis and treatment was started at Amirkabir University of Technology in 2012. The low-level RF system of the cyclotron accelerator is designed to stabilize acceleration voltage and control the resonance frequency of the cavity. In this work an Intelligent Low Level Radio Frequency Circuit or ILLRF, suitable for most AVF cyclotron accelerators, is designed using a beam monitoring device and narrow band tunable band-pass filter. In this design, the RF phase detection does not need signal processing by a microcontroller.

  19. Multi-interface Level Sensors and New Development in Monitoring and Control of Oil Separators

    Directory of Open Access Journals (Sweden)

    Wuqiang Yang

    2006-04-01

    Full Text Available In the oil industry, huge saving may be made if suitable multi-interface levelmeasurement systems are employed for effectively monitoring crude oil separators andefficient control of their operation. A number of techniques, e.g. externally mounteddisplacers, differential pressure transmitters and capacitance rod devices, have beendeveloped to measure the separation process with gas, oil, water and other components.Because of the unavailability of suitable multi-interface level measurement systems, oilseparators are currently operated by the trial-and-error approach. In this paper someconventional techniques, which have been used for level measurement in industry, and newdevelopment are discussed.

  20. A large-scale measurement, analysis and modelling of electromagnetic radiation levels in the vicinity of GSM/UMTS base stations in an urban area.

    Science.gov (United States)

    Karadağ, Teoman; Yüceer, Mehmet; Abbasov, Teymuraz

    2016-01-01

    The present study analyses the electric field radiating from the GSM/UMTS base stations located in central Malatya, a densely populated urban area in Turkey. The authors have conducted both instant and continuous measurements of high-frequency electromagnetic fields throughout their research by using non-ionising radiation-monitoring networks. Over 15,000 instant and 13,000,000 continuous measurements were taken throughout the process. The authors have found that the normal electric field radiation can increase ∼25% during daytime, depending on mobile communication traffic. The authors' research work has also demonstrated the fact that the electric field intensity values can be modelled for each hour, day or week with the results obtained from continuous measurements. The authors have developed an estimation model based on these values, including mobile communication traffic (Erlang) values obtained from mobile phone base stations and the temperature and humidity values in the environment. The authors believe that their proposed artificial neural network model and multivariable least-squares regression analysis will help predict the electric field intensity in an environment in advance. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.