WorldWideScience

Sample records for level instrumentation included

  1. Instrument reliability for high-level nuclear-waste-repository applications

    International Nuclear Information System (INIS)

    Rogue, F.; Binnall, E.P.; Armantrout, G.A.

    1983-01-01

    Reliable instrumentation will be needed to evaluate the characteristics of proposed high-level nuclear-wasted-repository sites and to monitor the performance of selected sites during the operational period and into repository closure. A study has been done to assess the reliability of instruments used in Department of Energy (DOE) waste repository related experiments and in other similar geological applications. The study included experiences with geotechnical, hydrological, geochemical, environmental, and radiological instrumentation and associated data acquisition equipment. Though this paper includes some findings on the reliability of instruments in each of these categories, the emphasis is on experiences with geotechnical instrumentation in hostile repository-type environments. We review the failure modes, rates, and mechanisms, along with manufacturers modifications and design changes to enhance and improve instrument performance; and include recommendations on areas where further improvements are needed

  2. Varying ultrasound power level to distinguish surgical instruments and tissue.

    Science.gov (United States)

    Ren, Hongliang; Anuraj, Banani; Dupont, Pierre E

    2018-03-01

    We investigate a new framework of surgical instrument detection based on power-varying ultrasound images with simple and efficient pixel-wise intensity processing. Without using complicated feature extraction methods, we identified the instrument with an estimated optimal power level and by comparing pixel values of varying transducer power level images. The proposed framework exploits the physics of ultrasound imaging system by varying the transducer power level to effectively distinguish metallic surgical instruments from tissue. This power-varying image-guidance is motivated from our observations that ultrasound imaging at different power levels exhibit different contrast enhancement capabilities between tissue and instruments in ultrasound-guided robotic beating-heart surgery. Using lower transducer power levels (ranging from 40 to 75% of the rated lowest ultrasound power levels of the two tested ultrasound scanners) can effectively suppress the strong imaging artifacts from metallic instruments and thus, can be utilized together with the images from normal transducer power levels to enhance the separability between instrument and tissue, improving intraoperative instrument tracking accuracy from the acquired noisy ultrasound volumetric images. We performed experiments in phantoms and ex vivo hearts in water tank environments. The proposed multi-level power-varying ultrasound imaging approach can identify robotic instruments of high acoustic impedance from low-signal-to-noise-ratio ultrasound images by power adjustments.

  3. Transient response of level instruments in a research reactor

    International Nuclear Information System (INIS)

    Cheng, Lap Y.

    1989-01-01

    A numerical model has been developed to simulate the dynamics of water level instruments in a research nuclear reactor. A bubble device, with helium gas as the working fluid, is used to monitor liquid level by sensing the static head pressure due to the height of liquid in the reactor vessel. A finite-difference model is constructed to study the transient response of the water level instruments to pressure perturbations. The field equations which describe the hydraulics of the helium gas in the bubbler device are arranged in the form of a tridiagonal matrix and the field variables are solved at each time step by the Thomas algorithm. Simulation results indicate that the dynamic response of the helium gas depends mainly on the volume and the inertia of the gas in the level instrument tubings. The anomalies in the simulated level indication are attributed to the inherent lag in the level instrument due to the hydraulics of the system. 1 ref., 5 figs

  4. High-Level Disinfection of Otorhinolaryngology Clinical Instruments: An Evaluation of the Efficacy and Cost-effectiveness of Instrument Storage.

    Science.gov (United States)

    Yalamanchi, Pratyusha; Yu, Jason; Chandler, Laura; Mirza, Natasha

    2018-01-01

    Objectives Despite increasing interest in individual instrument storage, risk of bacterial cross-contamination of otorhinolaryngology clinic instruments has not been assessed. This study is the first to determine the clinical efficacy and cost-effectiveness of standard high-level disinfection and clinic instrument storage. Methods To assess for cross-contamination, surveillance cultures of otorhinolaryngology clinic instruments subject to standard high-level disinfection and storage were obtained at the start and end of the outpatient clinical workday. Rate of microorganism recovery was compared with cultures of instruments stored in individual peel packs and control cultures of contaminated instruments. Based on historical clinic data, the direct allocation method of cost accounting was used to determine aggregate raw material cost and additional labor hours required to process and restock peel-packed instruments. Results Among 150 cultures of standard high-level disinfected and co-located clinic instruments, 3 positive bacterial cultures occurred; 100% of control cultures were positive for bacterial species ( P cost of individual semicritical instrument storage at $97,852.50 per year. Discussion With in vitro inoculation of >200 otorhinolaryngology clinic instruments, this study demonstrates that standard high-level disinfection and storage are equally efficacious to more time-consuming and expensive individual instrument storage protocols, such as peel packing, with regard to bacterial contamination. Implications for Practice Standard high-level disinfection and storage are equally effective to labor-intensive and costly individual instrument storage protocols.

  5. Portable instrumentation for quantitatively measuring radioactive surface contaminations, including 90Sr

    International Nuclear Information System (INIS)

    Brodzinski, R.L.

    1983-10-01

    In order to measure the effectiveness of decontamination efforts, a quantitative analysis of the radiocontamination is necessary, both before and after decontamination. Since it is desirable to release the decontaminated material for unrestricted use or disposal, the assay equipment must provide adequate sensitivity to measure the radioactivity at or below the release limit. In addition, the instrumentation must be capable of measuring all kinds of radiocontaminants including fission products, activation products, and transuranic materials. Finally, the survey instrumentation must be extremely versatile in order to assay the wide variety of contaminated surfaces in many environments, some of which may be extremely hostile or remote. This communication describes the development and application of portable instrumentation capable of quantitatively measuring most transuranics, activation products, and fission products, including 90 Sr, on almost any contaminated surface in nearly any location

  6. Lumbar lordosis restoration following single-level instrumented fusion comparing 4 commonly used techniques.

    Science.gov (United States)

    Dimar, John R; Glassman, Steven D; Vemuri, Venu M; Esterberg, Justin L; Howard, Jennifer M; Carreon, Leah Y

    2011-11-09

    A major sequelae of lumbar fusion is acceleration of adjacent-level degeneration due to decreased lumbar lordosis. We evaluated the effectiveness of 4 common fusion techniques in restoring lordosis: instrumented posterolateral fusion, translumbar interbody fusion, anteroposterior fusion with posterior instrumentation, and anterior interbody fusion with lordotic threaded (LT) cages (Medtronic Sofamor Danek, Memphis, Tennessee). Radiographs were measured preoperatively, immediately postoperatively, and a minimum of 6 months postoperatively. Parameters measured included anterior and posterior disk space height, lumbar lordosis from L3 to S1, and surgical level lordosis.No significant difference in demographics existed among the 4 groups. All preoperative parameters were similar among the 4 groups. Lumbar lordosis at final follow-up showed no difference between the anteroposterior fusion with posterior instrumentation, translumbar interbody fusion, and LT cage groups, although the posterolateral fusion group showed a significant loss of lordosis (-10°) (Plordosis and showed maintenance of anterior and posterior disk space height postoperatively compared with the other groups. Instrumented posterolateral fusion produces a greater loss of lordosis compared with anteroposterior fusion with posterior instrumentation, translumbar interbody fusion, and LT cages. Maintenance of lordosis and anterior and posterior disk space height is significantly better with anterior interbody fusion with LT cages. Copyright 2011, SLACK Incorporated.

  7. ASRDI oxygen technology survey. Volume 5: Density and liquid level measurement instrumentation for the cryogenic fluids oxygen, hydrogen, and nitrogen

    Science.gov (United States)

    Roder, H. M.

    1974-01-01

    Information is presented on instrumentation for density measurement, liquid level measurement, quantity gauging, and phase measurement. Coverage of existing information directly concerned with oxygen was given primary emphasis. A description of the physical principle of measurement for each instrumentation type is included. The basic materials of construction are listed if available from the source document for each instrument discussed. Cleaning requirements, procedures, and verification techniques are included.

  8. Downhole instrument including a flexible probe which can travel freely around bends in a borehole

    International Nuclear Information System (INIS)

    Dickinson III, B. W. O.

    1985-01-01

    Bore hole instrument and methods of manufacturing and using the same. The instrument includes an elongated flexible probe which is inserted into a bore hole and can travel freely around bends of relatively short radius in the hole. The probe includes a plurality of sensors, explosive charges or the like which are spaced apart and embedded in a flexible body comprising a mass of cushioning material, with a flexible outer casing of fabric having a high tensile strength. The probe is driven into a bore hole in piston-like fashion, and the flexible body enables the probe to travel freely around bends of relatively short radius. Instrumentation for processing signals from the probe is located at the surface of the earth, and a flexible cable interconnects the instrumentation with the probe

  9. FJ-2207 measuring instrument detection pipe surface a level of pollution method

    International Nuclear Information System (INIS)

    Wang Jiangong

    2010-01-01

    On the pipe surface contamination were detected α level of pollution is a frequently encountered dose-detection work. Because the pipeline surface arc, while the measuring probe for the plane, which for accurate measurement difficult. In this paper, on the FJ-2207-type pipe surface contamination measuring instrument measuring pollution levels in the α method was studied. Introduced the FJ-2207 measuring instrument detection pipe surface α pollution levels. Studied this measuring instrument on the same sources of surface, plane α level of radioactivity measured differences in the results obtained control of the apparatus when the direct measurement of the surface correction factor, and gives 32-216 specifications commonly used pipe direct measurement of the amendment factor. Convenient method, test results are reliable for the accurate measurement of pipe pollution levels in the surface of α as a reference and learning. (authors)

  10. On-ground calibration of the BEPICOLOMBO/SIMBIO-SYS at instrument level

    Science.gov (United States)

    Rodriguez-Ferreira, J.; Poulet, F.; Eng, P.; Longval, Y.; Dassas, K.; Arondel, A.; Langevin, Y.; Capaccioni, F.; Filacchione, G.; Palumbo, P.; Cremonese, G.; Dami, M.

    2012-04-01

    The Mercury Planetary Orbiter/BepiColombo carries an integrated suite of instruments, the Spectrometer and Imagers for MPO BepiColombo-Integrated Observatory SYStem (SIMBIO-SYS). SIMBIO-SYS has 3 channels: a stereo imaging system (STC), a high-resolution imager (HRIC) and a visible-near-infrared imaging spectrometer (VIHI). SIMBIO-SYS will scan the surface of Mercury with these three channels and determine the physical, morphological and compositional properties of the entire planet. Before integration on the S/C, an on-ground calibration at the channels and at the instrument levels will be performed so as to describe the instrumental responses as a function of various parameters that might evolve while the instruments will be operating [1]. The Institut d'Astrophysique Spatiale (IAS) is responsible for the on-ground instrument calibration at the instrument level. During the 4 weeks of calibration campaign planned for June 2012, the instrument will be maintained in a mechanical and thermal environment simulating the space conditions. Four Optical stimuli (QTH lamp, Integrating Sphere, BlackBody with variable temperature from 50 to 1200°C and Monochromator), are placed over an optical bench to illuminate the four channels so as to make the radiometric calibration, straylight monitoring, as well as spectral proofing based on laboratory mineral samples. The instrument will be mounted on a hexapod placed inside a thermal vacuum chamber during the calibration campaign. The hexapod will move the channels within the well-characterized incoming beam. We will present the key activities of the preparation of this calibration: the derivation of the instrument radiometric model, the implementation of the optical, mechanical and software interfaces of the calibration assembly, the characterization of the optical bench and the definition of the calibration procedures.

  11. New seismic instrumentation packaged for all terrestrial environments (including the quietest observatories!).

    Science.gov (United States)

    Parker, Tim; Devanney, Peter; Bainbridge, Geoff; Townsend, Bruce

    2017-04-01

    The march to make every type of seismometer, weak to strong motion, reliable and economically deployable in any terrestrial environment continues with the availability of three new sensors and seismic systems including ones with over 200dB of dynamic range. Until recently there were probably 100 pier type broadband sensors for every observatory type pier, not the types of deployments geoscientists are needing to advance science and monitoring capability. Deeper boreholes are now the recognized quieter environments for best observatory class instruments and these same instruments can now be deployed in direct burial environments which is unprecedented. The experiences of facilities in large deployments of broadband seismometers in continental scale rolling arrays proves the utility of packaging new sensors in corrosion resistant casings and designing in the robustness needed to work reliably in temporary deployments. Integrating digitizers and other sensors decreases deployment complexity, decreases acquisition and deployment costs, increases reliability and utility. We'll discuss the informed evolution of broadband pier instruments into the modern integrated field tools that enable economic densification of monitoring arrays along with supporting new ways to approach geoscience research in a field environment.

  12. An instrumentation and control philosophy for high-level nuclear waste processing facilities

    International Nuclear Information System (INIS)

    Weigle, D.H.

    1990-01-01

    The purpose of this paper is to present an instrumentation and control philosophy which may be applied to high-level nuclear waste processing facilities. This philosophy describes the recommended criteria for automatic/manual control, remote/local control, remote/local display, diagnostic instrumentation, interlocks, alarm levels, and redundancy. Due to the hazardous nature of the process constituents of a high-level nuclear waste processing facility, it is imperative that safety and control features required for accident-free operation and maintenance be incorporated. A well-instrumented and controlled process, while initially more expensive in capital and design costs, is generally safer and less expensive to operate. When the long term cost savings of a well designed process is coupled with the high savings enjoyed by accident avoidance, the benefits far outweigh the initial capital and design costs

  13. Optimization of biological and instrumental detection of explosives and ignitable liquid residues including canines, SPME/ITMS and GC/MSn

    Science.gov (United States)

    Furton, Kenneth G.; Harper, Ross J.; Perr, Jeannette M.; Almirall, Jose R.

    2003-09-01

    A comprehensive study and comparison is underway using biological detectors and instrumental methods for the rapid detection of ignitable liquid residues (ILR) and high explosives. Headspace solid phase microextraction (SPME) has been demonstrated to be an effective sampling method helping to identify active odor signature chemicals used by detector dogs to locate forensic specimens as well as a rapid pre-concentration technique prior to instrumental detection. Common ignitable liquids and common military and industrial explosives have been studied including trinitrotoluene, tetryl, RDX, HMX, EGDN, PETN and nitroglycerine. This study focuses on identifying volatile odor signature chemicals present, which can be used to enhance the level and reliability of detection of ILR and explosives by canines and instrumental methods. While most instrumental methods currently in use focus on particles and on parent organic compounds, which are often involatile, characteristic volatile organics are generally also present and can be exploited to enhance detection particularly for well-concealed devices. Specific examples include the volatile odor chemicals 2-ethyl-1-hexanol and cyclohexanone, which are readily available in the headspace of the high explosive composition C-4; whereas, the active chemical cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX) is not. The analysis and identification of these headspace 'fingerprint' organics is followed by double-blind dog trials of the individual components using certified teams in an attempt to isolate and understand the target compounds to which dogs are sensitive. Studies to compare commonly used training aids with the actual target explosive have also been undertaken to determine their suitability and effectiveness. The optimization of solid phase microextraction (SPME) combined with ion trap mobility spectrometry (ITMS) and gas chromatography/mass spectrometry/mass spectrometry (GC/MSn) is detailed including interface development

  14. The Development of a Tactical-Level Full Range Leadership Measurement Instrument

    Science.gov (United States)

    2010-03-01

    full range leadership theory has become established as the predominant and most widely researched theory on leadership . The most commonly used survey...instrument to assess full range leadership theory is the Multifactor Leadership Questionnaire, originally developed by Bass in 1985. Although much...existing literature to develop a new full range leadership theory measurement instrument that effectively targets low- to mid-level supervisors, or

  15. Latest NASA Instrument Cost Model (NICM): Version VI

    Science.gov (United States)

    Mrozinski, Joe; Habib-Agahi, Hamid; Fox, George; Ball, Gary

    2014-01-01

    The NASA Instrument Cost Model, NICM, is a suite of tools which allow for probabilistic cost estimation of NASA's space-flight instruments at both the system and subsystem level. NICM also includes the ability to perform cost by analogy as well as joint confidence level (JCL) analysis. The latest version of NICM, Version VI, was released in Spring 2014. This paper will focus on the new features released with NICM VI, which include: 1) The NICM-E cost estimating relationship, which is applicable for instruments flying on Explorer-like class missions; 2) The new cluster analysis ability which, alongside the results of the parametric cost estimation for the user's instrument, also provides a visualization of the user's instrument's similarity to previously flown instruments; and 3) includes new cost estimating relationships for in-situ instruments.

  16. An Instrument to Determine the Technological Literacy Levels of Upper Secondary School Students

    Science.gov (United States)

    Luckay, Melanie B.; Collier-Reed, Brandon I.

    2014-01-01

    In this article, an instrument for assessing upper secondary school students' levels of technological literacy is presented. The items making up the instrument emerged from a previous study that employed a phenomenographic research approach to explore students' conceptions of technology in terms of their understanding of the "nature…

  17. Nucleonic instruments from VUPJT Tesla

    International Nuclear Information System (INIS)

    Smola, J.

    1986-01-01

    The instruments currently produced by Tesla Premysleni are listed and briefly characterized. They include a low level alpha-beta counter, an automatic low level alpha-beta counter, detection units for environmental sample counting, instruments for measuring specific activity of liquids and radon concentration in water, a radioactive aerosol meter, dose ratemeters, portable alpha-beta indicators for surface contamintion monitoring, neutron monitors, single-, two- and three-channel spectrometric units. (M.D.)

  18. Providing instrumental social support is more beneficial to reduce mortality risk among the elderly with low educational level in Taiwan: a 12-year follow-up national longitudinal study.

    Science.gov (United States)

    Liao, C C; Yeh, C J; Lee, S H; Liao, W C; Liao, M Y; Lee, M C

    2015-04-01

    To evaluate whether the effects of providing or receiving social support are more beneficial to reduce mortality risk among the elderly with different educational levels. In this long-term prospective cohort study, data were retrieved from the Taiwan Longitudinal Study on Aging. This study was initiated from 1996 until 2007. The complete data from 1492 males and 1177 females aged ≥67 years were retrieved. Participants received financial, instrumental, and emotional support, and they actively provided instrumental and emotional support to others and involved in social engagement. Education attainment was divided into two levels: high and low. The low education level included illiterate and elementary school. The high education level included junior high school to senior high school and above college. Cox regression analysis was used to examine the association between providing or receiving social support on mortality with different educational levels. The average age of the participants in 1996 was 73.0 (IQR=8.0) years, and the median survival following years (1996-2007) of participants was 10.3 (IQR=6.7) years. Most participants were low educational level including illiterate (39.3%) and elementary school (41.2%). Participants with high educational level tend to be younger and more male significantly. On the contrary, participants with low educational level tend to have significant more poor income, more depression, more cognition impairment, more with IADL and ADL disability than high educational level. Most participants received instrumental support from others (95.5%) and also provided emotional support to others (97.7%). Providing instrumental support can reduce 17% of mortality risk among the elderly with a low level of education after adjusting several covariates [Hazard ratio (HR) = 0.83; 95% confidence interval (CI) = 0.70-0.99; p = 0.036]. Providing instrumental social support to others confer benefits to the giver and prolong life expectancy among the

  19. Influence of Rotary Instrumentation with Continuous Irrigation on Pain and Neuropeptide Release Levels: A Randomized Clinical Trial.

    Science.gov (United States)

    Bıçakcı, Hazal; Çapar, İsmail Davut; Genç, Selin; İhtiyar, Alperen; Sütçü, Recep

    2016-11-01

    The first objective was to determine correlation among various experimental and clinical pain measurement procedures. The second objective was to evaluate the influence of rotary instrumentation with continuous irrigation on pain and neuropeptide release levels. Forty patients who had preoperative pain at the levels of 3-8 on the visual analogue scale were included. Gingival crevicular fluid (GCF) samples were collected. Patients were randomly assigned to 2 treatment groups, the standard preparation group and the preparation with continuous irrigation group. Apical fluid samples (AFS) were collected after instrumentation. In the second visit, the patients' pain levels were recorded, and GCF and AFS were obtained. Substance P, calcitonin-gene related peptide (CGRP), interleukin (IL)-1β, and IL-10 levels were analyzed from the GCF and AFS samples. For comparison between groups, the Mann-Whitney test was used (P Rotary preparation with continuous irrigation has not been more effective than the standard preparation method for reducing pain. Because of determination of the correlation between CGRP and IL-10 with percussion pain, these neuropeptides can be used in further studies. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  20. The Development of a Secondary-Level Solo Wind Instrument Performance Rubric Using the Multifaceted Rasch Partial Credit Measurement Model

    Science.gov (United States)

    Wesolowski, Brian C.; Amend, Ross M.; Barnstead, Thomas S.; Edwards, Andrew S.; Everhart, Matthew; Goins, Quentin R.; Grogan, Robert J., III; Herceg, Amanda M.; Jenkins, S. Ira; Johns, Paul M.; McCarver, Christopher J.; Schaps, Robin E.; Sorrell, Gary W.; Williams, Jonathan D.

    2017-01-01

    The purpose of this study was to describe the development of a valid and reliable rubric to assess secondary-level solo instrumental music performance based on principles of invariant measurement. The research questions that guided this study included (1) What is the psychometric quality (i.e., validity, reliability, and precision) of a scale…

  1. Critical Science Instrument Alignment of the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM)

    Science.gov (United States)

    Rohrbach, Scott O.; Kubalak, David A.; Gracey, Renee M.; Sabatke, Derek S.; Howard, Joseph M.; Telfer, Randal C.; Zielinski, Thomas P.

    2016-01-01

    This paper describes the critical instrument alignment terms associated with the six-degree of freedom alignment of each the Science Instrument (SI) in the James Webb Space Telescope (JWST), including focus, pupil shear, pupil clocking, and boresight. We present the test methods used during cryogenic-vacuum tests to directly measure the performance of each parameter, the requirements levied on each, and the impact of any violations of these requirements at the instrument and Observatory level.

  2. MEASURING INSTRUMENT CONSTRUCTION AND VALIDATION IN ESTIMATING UNICYCLING SKILL LEVEL

    Directory of Open Access Journals (Sweden)

    Ivan Granić

    2012-09-01

    Full Text Available Riding the unicycle presupposes the knowledge of the set of elements which describe motoric skill, or just part of that set with which we could measure the level of that knowledge. Testing and evaluation of the elements is time consuming. In order to design a unique, composite measuring instrument, to facilitate the evaluation of the initial level of unicycling skill, we tested 17 recreative subjects who were learning to ride the unicycle in 15 hours of training, without any previous knowledge or experience what was measured before the beginning of the training. At the beginning and at the end of the training they were tested with the set of the 12 riding elements test that was carried out to record only successful attempts, followed by unique SLALOM test which include previously tested elements. It was found that the unique SLALOM test has good metric features and a high regression coefficient showed that the SLALOM could be used instead of the 12 elements of unicycle riding skill, and it could be used as a uniform test to evaluate learned or existing knowledge. Because of its simplicity in terms of action and simultaneous testing of more subjects, the newly constructed test could be used in evaluating the unicycling recreational level, but also for monitoring and programming transformation processes to develop the motor skills of riding of unicycle. Because of its advantages, it is desirable to include unicycling in the educational processes of learning new motor skills, which can be evaluated by the results of this research. The obtained results indicate that the unicycle should be seriously consider as a training equipment to “refresh” or expand the recreational programs, without any fear that it is just for special people. Namely, it was shown that the previously learned motor skills (skiing, roller-skating, and cycling had no effect on the results of final testing.

  3. Instrumental methods of analysis, 7th edition

    International Nuclear Information System (INIS)

    Willard, H.H.; Merritt, L.L. Jr.; Dean, J.A.; Settle, F.A. Jr.

    1988-01-01

    The authors have prepared an organized and generally polished product. The book is fashioned to be used as a textbook for an undergraduate instrumental analysis course, a supporting textbook for graduate-level courses, and a general reference work on analytical instrumentation and techniques for professional chemists. Four major areas are emphasized: data collection and processing, spectroscopic instrumentation and methods, liquid and gas chromatographic methods, and electrochemical methods. Analytical instrumentation and methods have been updated, and a thorough citation of pertinent recent literature is included

  4. Instrumentation development

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    Areas being investigated for instrumentation improvement during low-level pollution monitoring include laser opto-acoustic spectroscopy, x-ray fluorescence spectroscopy, optical fluorescence spectroscopy, liquid crystal gas detectors, advanced forms of atomic absorption spectroscopy, electro-analytical chemistry, and mass spectroscopy. Emphasis is also directed toward development of physical methods, as opposed to conventional chemical analysis techniques for monitoring these trace amounts of pollution related to energy development and utilization

  5. Thermal and Alignment Analysis of the Instrument-Level ATLAS Thermal Vacuum Test

    Science.gov (United States)

    Bradshaw, Heather

    2012-01-01

    This paper describes the thermal analysis and test design performed in preparation for the ATLAS thermal vacuum test. NASA's Advanced Topographic Laser Altimeter System (ATLAS) will be flown as the sole instrument aboard the Ice, Cloud, and land Elevation Satellite-2 (ICESat-2). It will be used to take measurements of topography and ice thickness for Arctic and Antarctic regions, providing crucial data used to predict future changes in worldwide sea levels. Due to the precise measurements ATLAS is taking, the laser altimeter has very tight pointing requirements. Therefore, the instrument is very sensitive to temperature-induced thermal distortions. For this reason, it is necessary to perform a Structural, Thermal, Optical Performance (STOP) analysis not only for flight, but also to ensure performance requirements can be operationally met during instrument-level thermal vacuum testing. This paper describes the thermal model created for the chamber setup, which was used to generate inputs for the environmental STOP analysis. This paper also presents the results of the STOP analysis, which indicate that the test predictions adequately replicate the thermal distortions predicted for flight. This is a new application of an existing process, as STOP analyses are generally performed to predict flight behavior only. Another novel aspect of this test is that it presents the opportunity to verify pointing results of a STOP model, which is not generally done. It is possible in this case, however, because the actual pointing will be measured using flight hardware during thermal vacuum testing and can be compared to STOP predictions.

  6. Instrumentation for the uranium mining industry

    International Nuclear Information System (INIS)

    Gray, R.A.

    1978-01-01

    Brief descriptions are presented concerning instruments used in uranium mining, including R meter, radon daughter working level counter, radon gas detectors, alpha contamination monitors, air samplers, ore grade evaluators and gamma energy analyzers

  7. Spectroelectrochemical Instrument Measures TOC

    Science.gov (United States)

    Kounaves, Sam

    2011-01-01

    A spectroelectrochemical instrument has been developed for measuring the total organic carbon (TOC) content of an aqueous solution. Measurements of TOC are frequently performed in environmental, clinical, and industrial settings. Until now, techniques for performing such measurements have included, various ly, the use of hazardous reagents, ultraviolet light, or ovens, to promote reactions in which the carbon contents are oxidized. The instrument now being developed is intended to be a safer, more economical means of oxidizing organic carbon and determining the TOC levels of aqueous solutions and for providing a low power/mass unit for use in planetary missions.

  8. A new instrument to assess physician skill at thoracic ultrasound, including pleural effusion markup.

    Science.gov (United States)

    Salamonsen, Matthew; McGrath, David; Steiler, Geoff; Ware, Robert; Colt, Henri; Fielding, David

    2013-09-01

    To reduce complications and increase success, thoracic ultrasound is recommended to guide all chest drainage procedures. Despite this, no tools currently exist to assess proceduralist training or competence. This study aims to validate an instrument to assess physician skill at performing thoracic ultrasound, including effusion markup, and examine its validity. We developed an 11-domain, 100-point assessment sheet in line with British Thoracic Society guidelines: the Ultrasound-Guided Thoracentesis Skills and Tasks Assessment Test (UGSTAT). The test was used to assess 22 participants (eight novices, seven intermediates, seven advanced) on two occasions while performing thoracic ultrasound on a pleural effusion phantom. Each test was scored by two blinded expert examiners. Validity was examined by assessing the ability of the test to stratify participants according to expected skill level (analysis of variance) and demonstrating test-retest and intertester reproducibility by comparison of repeated scores (mean difference [95% CI] and paired t test) and the intraclass correlation coefficient. Mean scores for the novice, intermediate, and advanced groups were 49.3, 73.0, and 91.5 respectively, which were all significantly different (P < .0001). There were no significant differences between repeated scores. Procedural training on mannequins prior to unsupervised performance on patients is rapidly becoming the standard in medical education. This study has validated the UGSTAT, which can now be used to determine the adequacy of thoracic ultrasound training prior to clinical practice. It is likely that its role could be extended to live patients, providing a way to document ongoing procedural competence.

  9. Refabricated and instrumented fuel rods

    International Nuclear Information System (INIS)

    Silberstein, K.

    2005-01-01

    Nuclear Fuel for power reactors capabilities evaluation is strongly based on the intimate knowledge of its behaviour under irradiation. This knowledge can be acquired from refabricated and instrumented fuel rods irradiated at different levels in commercial reactors. This paper presents the development and qualification of a new technique called RECTO related to a double-instrumented rod re-fabrication process developed by CEA/LECA hot laboratory facility at CADARACHE. The technique development includes manufacturing of the properly dimensioned cavity in the fuel pellet stack to house the thermocouple and the use of a newly designed pressure transducer. An analytic irradiation of such a double-instrumented fuel rod will be performed in OSIRIS test reactor starting October 2004. (Author)

  10. Work group I: Measures of the food and physical activity environment: instruments.

    Science.gov (United States)

    Saelens, Brian E; Glanz, Karen

    2009-04-01

    A work group was convened to identify the core challenges, content gaps, and corresponding possible solutions for improving food- and physical activity-environment instrumentation. Identified challenges included instrument proliferation, the scaling or grain of instruments and appropriate aggregation to the neighborhood or community level, and unknown sensitivity to change of most instruments. Solutions for addressing these challenges included establishing an interactive and real-time instrument repository, developing and enforcing high standards for instrument reporting, increasing community-researcher collaborations, and implementing surveillance of food and physical activity environment. Solid instrumentation will accelerate a better understanding of food- and physical activity-environment effects on eating and physical activity behaviors.

  11. Instrumental analysis by gamma spectrometry of low level caesium-137 in marine samples

    International Nuclear Information System (INIS)

    Figueira, R.C.L.; Silva, L.R.N.; Figueiredo, A.M.G.; Cunha, I.I.L.

    1998-01-01

    An instrumental method for the analysis of low levels of 137 Cs in marine samples consists in calibrating the detector, determining the counting efficiency of the detector, accumulative counts of background and sample and smoothing the 661.6 keV photopeak. The methodology was applied to reference samples containing low levels of 137 Cs, showing a good accuracy. It was further applied to sediment samples from the southern coast of Brazil. The levels obtained ranged between 1.0 and 1.8 Bq.kg -1 , and the lower limit of detection and minimum detectable concentration values were 10 mBq and 0.28 Bq.kg -1 , respectively. (author)

  12. Monte Carlo simulations of neutron-scattering instruments using McStas

    DEFF Research Database (Denmark)

    Nielsen, K.; Lefmann, K.

    2000-01-01

    Monte Carlo simulations have become an essential tool for improving the performance of neutron-scattering instruments, since the level of sophistication in the design of instruments is defeating purely analytical methods. The program McStas, being developed at Rise National Laboratory, includes...

  13. Goal-directed behaviour and instrumental devaluation: a neural system-level computational model

    Directory of Open Access Journals (Sweden)

    Francesco Mannella

    2016-10-01

    Full Text Available Devaluation is the key experimental paradigm used to demonstrate the presence of instrumental behaviours guided by goals in mammals. We propose a neural system-level computational model to address the question of which brain mechanisms allow the current value of rewards to control instrumental actions. The model pivots on and shows the computational soundness of the hypothesis for which the internal representation of instrumental manipulanda (e.g., levers activate the representation of rewards (or `action-outcomes', e.g. foods while attributing to them a value which depends on the current internal state of the animal (e.g., satiation for some but not all foods. The model also proposes an initial hypothesis of the integrated system of key brain components supporting this process and allowing the recalled outcomes to bias action selection: (a the sub-system formed by the basolateral amygdala and insular cortex acquiring the manipulanda-outcomes associations and attributing the current value to the outcomes; (b the three basal ganglia-cortical loops selecting respectively goals, associative sensory representations, and actions; (c the cortico-cortical and striato-nigro-striatal neural pathways supporting the selection, and selection learning, of actions based on habits and goals. The model reproduces and integrates the results of different devaluation experiments carried out with control rats and rats with pre- and post-training lesions of the basolateral amygdala, the nucleus accumbens core, the prelimbic cortex, and the dorso-medial striatum. The results support the soundness of the hypotheses of the model and show its capacity to integrate, at the system-level, the operations of the key brain structures underlying devaluation. Based on its hypotheses and predictions, the model also represents an operational framework to support the design and analysis of new experiments on the motivational aspects of goal-directed behaviour.

  14. DOE Fundamentals Handbook: Instrumentation and Control, Volume 1

    International Nuclear Information System (INIS)

    1992-06-01

    The Instrumentation and Control Fundamentals Handbook was developed to assist nuclear facility operating contractors provide operators, maintenance personnel, and the technical staff with the necessary fundamentals training to ensure a basic understanding of instrumentation and control systems. The handbook includes information on temperature, pressure, flow, and level detection systems; position indication systems; process control systems; and radiation detection principles. This information will provide personnel with an understanding of the basic operation of various types of DOE nuclear facility instrumentation and control systems

  15. DOE Fundamentals Handbook: Instrumentation and Control, Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    1992-06-01

    The Instrumentation and Control Fundamentals Handbook was developed to assist nuclear facility operating contractors provide operators, maintenance personnel, and the technical staff with the necessary fundamentals training to ensure a basic understanding of instrumentation and control systems. The handbook includes information on temperature, pressure, flow, and level detection systems; position indication systems; process control systems; and radiation detection principles. This information will provide personnel with an understanding of the basic operation of various types of DOE nuclear facility instrumentation and control systems.

  16. DOE Fundamentals Handbook: Instrumentation and Control, Volume 2

    International Nuclear Information System (INIS)

    1992-06-01

    The Instrumentation and Control Fundamentals Handbook personnel, and the technical staff facility operating contractors provide operators, maintenance personnel, and the technical staff with the necessary fundamentals training to ensure a basic understanding of instrumentation and control systems. The handbook includes information on temperature, pressure, flow, and level detection systems; position indication systems; process control systems; and radiation detection principles. This information will provide personnel with an understanding of the basic operation of various types of DOE nuclear facility instrumentation and control systems

  17. Radioisotope instruments

    CERN Document Server

    Cameron, J F; Silverleaf, D J

    1971-01-01

    International Series of Monographs in Nuclear Energy, Volume 107: Radioisotope Instruments, Part 1 focuses on the design and applications of instruments based on the radiation released by radioactive substances. The book first offers information on the physical basis of radioisotope instruments; technical and economic advantages of radioisotope instruments; and radiation hazard. The manuscript then discusses commercial radioisotope instruments, including radiation sources and detectors, computing and control units, and measuring heads. The text describes the applications of radioisotop

  18. On Representative Spaceflight Instrument and Associated Instrument Sensor Web Framework

    Science.gov (United States)

    Kizhner, Semion; Patel, Umeshkumar; Vootukuru, Meg

    2007-01-01

    Sensor Web-based adaptation and sharing of space flight mission resources, including those of the Space-Ground and Control-User communication segment, could greatly benefit from utilization of heritage Internet Protocols and devices applied for Spaceflight (SpaceIP). This had been successfully demonstrated by a few recent spaceflight experiments. However, while terrestrial applications of Internet protocols are well developed and understood (mostly due to billions of dollars in investments by the military and industry), the spaceflight application of Internet protocols is still in its infancy. Progress in the developments of SpaceIP-enabled instrument components will largely determine the SpaceIP utilization of those investments and acceptance in years to come. Likewise SpaceIP, the development of commercial real-time and instrument colocated computational resources, data compression and storage, can be enabled on-board a spacecraft and, in turn, support a powerful application to Sensor Web-based design of a spaceflight instrument. Sensor Web-enabled reconfiguration and adaptation of structures for hardware resources and information systems will commence application of Field Programmable Arrays (FPGA) and other aerospace programmable logic devices for what this technology was intended. These are a few obvious potential benefits of Sensor Web technologies for spaceflight applications. However, they are still waiting to be explored. This is because there is a need for a new approach to spaceflight instrumentation in order to make these mature sensor web technologies applicable for spaceflight. In this paper we present an approach in developing related and enabling spaceflight instrument-level technologies based on the new concept of a representative spaceflight Instrument Sensor Web (ISW).

  19. Instruments to assess integrated care

    DEFF Research Database (Denmark)

    Lyngsø, Anne Marie; Godtfredsen, Nina Skavlan; Høst, Dorte

    2014-01-01

    INTRODUCTION: Although several measurement instruments have been developed to measure the level of integrated health care delivery, no standardised, validated instrument exists covering all aspects of integrated care. The purpose of this review is to identify the instruments concerning how to mea...... was prevalent. It is uncertain whether development of a single 'all-inclusive' model for assessing integrated care is desirable. We emphasise the continuing need for validated instruments embedded in theoretical contexts.......INTRODUCTION: Although several measurement instruments have been developed to measure the level of integrated health care delivery, no standardised, validated instrument exists covering all aspects of integrated care. The purpose of this review is to identify the instruments concerning how...... to measure the level of integration across health-care sectors and to assess and evaluate the organisational elements within the instruments identified. METHODS: An extensive, systematic literature review in PubMed, CINAHL, PsycINFO, Cochrane Library, Web of Science for the years 1980-2011. Selected...

  20. Design and validation of the INICIARE instrument, for the assessment of dependency level in acutely ill hospitalised patients.

    Science.gov (United States)

    Morales-Asencio, José Miguel; Porcel-Gálvez, Ana María; Oliveros-Valenzuela, Rosa; Rodríguez-Gómez, Susana; Sánchez-Extremera, Lucrecia; Serrano-López, Francisco Andrés; Aranda-Gallardo, Marta; Canca-Sánchez, José Carlos; Barrientos-Trigo, Sergio

    2015-03-01

    The aim of this study was to establish the validity and reliability of an instrument (Inventario del NIvel de Cuidados mediante IndicAdores de clasificación de Resultados de Enfermería) used to assess the dependency level in acutely hospitalised patients. This instrument is novel, and it is based on the Nursing Outcomes Classification. Multiple existing instruments for needs assessment have been poorly validated and based predominately on interventions. Standardised Nursing Languages offer an ideal framework to develop nursing sensitive instruments. A cross-sectional validation study in two acute care hospitals in Spain. This study was implemented in two phases. First, the research team developed the instrument to be validated. In the second phase, the validation process was performed by experts, and the data analysis was conducted to establish the psychometric properties of the instrument. Seven hundred and sixty-one patient ratings performed by nurses were collected during the course of the research study. Data analysis yielded a Cronbach's alpha of 0·91. An exploratory factorial analysis identified three factors (Physiological, Instrumental and Cognitive-behavioural), which explained 74% of the variance. Inventario del NIvel de Cuidados mediante IndicAdores de clasificación de Resultados de Enfermería was demonstrated to be a valid and reliable instrument based on its use in acutely hospitalised patients to assess the level of dependency. Inventario del NIvel de Cuidados mediante IndicAdores de clasificación de Resultados de Enfermería can be used as an assessment tool in hospitalised patients during the nursing process throughout the entire hospitalisation period. It contributes information to support decisions on nursing diagnoses, interventions and outcomes. It also enables data codification in large databases. © 2014 John Wiley & Sons Ltd.

  1. Geotechnical instrumentation for repository shafts

    International Nuclear Information System (INIS)

    Lentell, R.L.; Byrne, J.

    1993-01-01

    The US Congress passed the Nuclear Waste Policy Act in 1980, which required that three distinctly different geologic media be investigated as potential candidate sites for the permanent disposal of high-level nuclear waste. The three media that were selected for study were basalt (WA), salt (TX, LA, MS, UT), and tuff (NV). Preliminary Exploratory Shaft Facilities (ESF) designs were prepared for seven candidate salt sites, including bedded and domal salt environments. A bedded-salt site was selected in Deaf Smith County, TX for detailed site characterization studies and ESF Final Design. Although Congress terminated the Salt Repository Program in 1988, Final Design for the Deaf Smith ESF was completed, and much of the design rationale can be applied to subsequent deep repository shafts. This paper presents the rationale for the geotechnical instrumentation that was designed for construction and operational performance monitoring of the deep shafts of the in-situ test facility. The instrumentation design described herein can be used as a general framework in designing subsequent instrumentation programs for future high-level nuclear waste repository shafts

  2. Semi-custom integrated circuit amplifier and level discriminator for nuclear and space instruments

    International Nuclear Information System (INIS)

    Hahn, S.F.; Cafferty, M.M.

    1991-01-01

    This paper reports on the development an extra fast current feedback amplifier and a level discriminator employing a dielectrically-isolated bipolar, semi-custom Application Specific Integrated Circuit (ASIC) process. These devices are specifically designed for instruments aboard spacecrafts or in portable packages requiring low power and weight. The amplifier adopts current feedback for a unity-gain bandwidth of 90 MHz while consuming 50 mW. The level discriminator uses a complementary output driver for balanced positive and negative response times. The power consumption of these devices can be programmed by external resistors for optimal speed and power trade-off

  3. Semi-custom integrated circuit amplifier and level discriminator for nuclear and space instruments

    International Nuclear Information System (INIS)

    Hahn, S.F.; Cafferty, M.M.

    1990-01-01

    This paper reports an extra fast current feedback amplifier and a level discriminator developed employing a dielectrically isolated bipolar, semi-custom Application Specific Integrated Circuit (ASIC) process. These devices are specifically designed for instruments aboard spacecrafts or in portable packages requiring low power and weight. The amplifier adopts current feedback for a unity- gain bandwidth of 90 MHz while consuming 50 mW. The level discriminator uses a complementary output driver for balanced positive and negative response times. The power consumption of these devices can be programmed by external resistors for optimal speed and power trade-off

  4. Field instrumentation and testing needs for a high level waste repository

    International Nuclear Information System (INIS)

    Marti, J.; Maini, T.

    1981-03-01

    A review has been conducted of the testing and measurement needs posed by a deep geologic High Level Waste (HLW) repository in crystalline or argillaceous rocks. Siting, design, construction, operation and decommissioning of the repository have been covered, together with the planning of a Test and Demonstration Facility. Instruments and methods available have been critically assessed in their ability to fulfil the aforementioned testing and monitoring programmes. Special attention has been paid to the relation of measurements to the data needs and to the tests likely to generate such data. This assessment has concentrated on measurements of absolute rock stresses, monitoring of changes in rock stress, evaluation of the rock mass deformability, measurement of relative displacements and determination of the hydrogeologic parameters of the rock mass. Other measurements have been studied with a lesser degree of attention. The overall conclusion is that, from the instrumentation and testing points of view, present plans for a test and demonstration facility in the early nineties and a repository soon after 2000 are indeed feasible. Specific conclusions on the state-of-the-art and development needs are presented in the report. (author)

  5. Literature Review of Multicultural Instrumentation

    Science.gov (United States)

    Sarraj, Huda; Carter, Stacy; Burley, Hansel

    2015-01-01

    Demographic changes at the national level emphasize a critical need for multicultural education to be included as part of undergraduate education. This critical review of the literature examines 10 multicultural instruments that are suitable for use in K-12 or higher education institutions. This is a novel literature review in that it is the first…

  6. NASA Instrument Cost/Schedule Model

    Science.gov (United States)

    Habib-Agahi, Hamid; Mrozinski, Joe; Fox, George

    2011-01-01

    NASA's Office of Independent Program and Cost Evaluation (IPCE) has established a number of initiatives to improve its cost and schedule estimating capabilities. 12One of these initiatives has resulted in the JPL developed NASA Instrument Cost Model. NICM is a cost and schedule estimator that contains: A system level cost estimation tool; a subsystem level cost estimation tool; a database of cost and technical parameters of over 140 previously flown remote sensing and in-situ instruments; a schedule estimator; a set of rules to estimate cost and schedule by life cycle phases (B/C/D); and a novel tool for developing joint probability distributions for cost and schedule risk (Joint Confidence Level (JCL)). This paper describes the development and use of NICM, including the data normalization processes, data mining methods (cluster analysis, principal components analysis, regression analysis and bootstrap cross validation), the estimating equations themselves and a demonstration of the NICM tool suite.

  7. Item-level psychometrics of the ADL instrument of the Korean National Survey on persons with physical disabilities.

    Science.gov (United States)

    Hong, Ickpyo; Lee, Mi Jung; Kim, Moon Young; Park, Hae Yean

    2017-10-01

    The aim of this study is to investigate the psychometrics of the 12 items of an instrument assessing activities of daily living (ADL) using an item response theory model. A total of 648 adults with physical disabilities and having difficulties in ADLs were retrieved from the 2014 Korean National Survey on People with Disabilities. The psychometric testing included factor analysis, internal consistency, precision, and differential item functioning (DIF) across categories including sex, older age, marital status, and physical impairment area. The sample had a mean age of 69.7 years old (SD = 13.7). The majority of the sample had lower extremity impairments (62.0%) and had at least 2.1 chronic conditions. The instrument demonstrated unidimensional construct and good internal consistency (Cronbach's alpha = 0.95). The instrument precisely estimated person measures within a wide range of theta values (-2.22 logits  5.0%). Our findings indicate that the dressing item would need to be modified to improve its psychometrics. Overall, the ADL instrument demonstrates good psychometrics, and thus, it may be used as a standardized instrument for measuring disability in rehabilitation contexts. However, the findings are limited to adults with physical disabilities. Future studies should replicate psychometric testing for survey respondents with other disorders and for children.

  8. Development Scaffolding for Construction of Evaluation Instrument Training Program on The Cognitive Domain For Senior High School Physics Teachers and The Same Level

    Science.gov (United States)

    Arif, W.; Suhandi, A.; Kaniawati, I.; Setiawan, A.

    2017-02-01

    The development of scaffolding for evaluation instrument construction training program on the cognitive domain for senior high school physics teacher and the same level that is specified in the test instrument has been done. This development was motivated by the low ability of the majority of physics teachers in constructing the physics learning achievement test. This situation not in accordance with the demands of Permendiknas RI no. 16 tahun 2007 concerning the standard of academic qualifications and competence of teachers, stating that teachers should have a good ability to develop instruments for assessment and evaluation of process and learning outcomes. Based on the preliminary study results, it can be seen that the main cause of the inability of teachers in developing physics achievement test is because they do not good understand of the indicators for each aspect of cognitive domains. Scaffolding development is done by using the research and development methods formulated by Thiagarajan which includes define, design and develope steps. Develop step includes build the scaffolding, validation of scaffolding by experts and the limited pilot implementations on the training activities. From the build scaffolding step, resulted the scaffolding for the construction of test instruments training program which include the process steps; description of indicators, operationalization of indicators, construction the itemsframework (items scenarios), construction the items stem, construction the items and checking the items. The results of the validation by three validator indicates that the built scaffolding are suitable for use in the construction of physics achievement test training program, especially for novice. The limited pilot implementation of the built scaffolding conducted in training activities attended by 10 senior high school physics teachers in Garut district. The results of the limited pilot implementation shows that the built scaffolding have a medium

  9. A borehole instrumentation program for characterization of unsaturated-zone percolation

    International Nuclear Information System (INIS)

    Kume, J.; Rousseau, J.P.

    1994-01-01

    A borehole instrumentation and monitoring program has been designed by the US Geological Survey to support site characterization of unsaturated-zone percolation at Yucca Mountain, Nye County, Nevada. This program provides a means of defining the unsaturated-zone fluid flow (liquid and gas) potential field in a setting that incorporates large-scale stratigraphic and structural features, and the influences of geothermal heat flow and atmospheric pressure changes. Data derived from this program will be used to evaluate the suitability of Yucca Mountain as a mined geologic-repository for the storage of high-level, radioactive waste. These data include in-situ temperature, pneumatic pressure, and water potential. In addition, the instrumentation program provides facilities for gas-sampling, gas-tracer diffusion testing, water-injection testing, water-level monitoring, neutron moisture-meter monitoring, temperature profiling, and in-situ recalibration of the downhole sensors. The program included testing and development of: (1) precision sensors for measurement; (2) a downhole instrumentation-station-apparatus to house the sensors, recalibrate sensors in-situ, and allow access to instrument stations for other testing purposes; and (3) surface-based support and instrumentation facilities

  10. Development of diagnostic test instruments to reveal level student conception in kinematic and dynamics

    Science.gov (United States)

    Handhika, J.; Cari, C.; Suparmi, A.; Sunarno, W.; Purwandari, P.

    2018-03-01

    The purpose of this research was to develop a diagnostic test instrument to reveal students' conceptions in kinematics and dynamics. The diagnostic test was developed based on the content indicator the concept of (1) displacement and distance, (2) instantaneous and average velocity, (3) zero and constant acceleration, (4) gravitational acceleration (5) Newton's first Law, (6) and Newton's third Law. The diagnostic test development model includes: Diagnostic test requirement analysis, formulating test-making objectives, developing tests, checking the validity of the content and the performance of reliability, and application of tests. The Content Validation Index (CVI) results in the category are highly relevant, with a value of 0.85. Three questions get negative Content Validation Ratio CVR) (-0.6), after revised distractors and clarify visual presentation; the CVR become 1 (highly relevant). This test was applied, obtained 16 valid test items, with Cronbach Alpha value of 0.80. It can conclude that diagnostic test can be used to reveal the level of students conception in kinematics and dynamics.

  11. The challenges of developing an instrument to assess health provider motivation at primary care level in rural Burkina Faso, Ghana, and Tanzania

    Directory of Open Access Journals (Sweden)

    Helen Prytherch

    2012-10-01

    Full Text Available Background: The quality of health care depends on the competence and motivation of the health workers that provide it. In the West, several tools exist to measure worker motivation, and some have been applied to the health sector. However, none have been validated for use in sub-Saharan Africa. The complexity of such tools has also led to concerns about their application at primary care level. Objective: To develop a common instrument to monitor any changes in maternal and neonatal health (MNH care provider motivation resulting from the introduction of pilot interventions in rural, primary level facilities in Ghana, Burkina Faso, and Tanzania. Design: Initially, a conceptual framework was developed. Based upon this, a literature review and preliminary qualitative research, an English-language instrument was developed and validated in an iterative process with experts from the three countries involved. The instrument was then piloted in Ghana. Reliability testing and exploratory factor analysis were used to produce a final, parsimonious version. Results and discussion: This paper describes the actual process of developing the instrument. Consequently, the concepts and items that did not perform well psychometrically at pre-test are first presented and discussed. The final version of the instrument, which comprises 42 items for self-assessment and eight for peer-assessment, is then shown. This is followed by a presentation and discussion of the findings from first use of the instrument with MNH providers from 12 rural, primary level facilities in each of the three countries. Conclusions: It is possible to undertake work of this nature at primary health care level, particularly if the instruments are kept as straightforward as possible and well introduced. However, their development requires very lengthy preparatory periods. The effort needed to adapt such instruments for use in different countries within the region of sub-Saharan Africa should not

  12. The challenges of developing an instrument to assess health provider motivation at primary care level in rural Burkina Faso, Ghana and Tanzania

    Science.gov (United States)

    Prytherch, Helen; Leshabari, Melkidezek T.; Wiskow, Christiane; Aninanya, Gifty A.; Kakoko, Deodatus C.V.; Kagoné, Moubassira; Burghardt, Juliane; Kynast-Wolf, Gisela; Marx, Michael; Sauerborn, Rainer

    2012-01-01

    Background The quality of health care depends on the competence and motivation of the health workers that provide it. In the West, several tools exist to measure worker motivation, and some have been applied to the health sector. However, none have been validated for use in sub-Saharan Africa. The complexity of such tools has also led to concerns about their application at primary care level. Objective To develop a common instrument to monitor any changes in maternal and neonatal health (MNH) care provider motivation resulting from the introduction of pilot interventions in rural, primary level facilities in Ghana, Burkina Faso, and Tanzania. Design Initially, a conceptual framework was developed. Based upon this, a literature review and preliminary qualitative research, an English-language instrument was developed and validated in an iterative process with experts from the three countries involved. The instrument was then piloted in Ghana. Reliability testing and exploratory factor analysis were used to produce a final, parsimonious version. Results and discussion This paper describes the actual process of developing the instrument. Consequently, the concepts and items that did not perform well psychometrically at pre-test are first presented and discussed. The final version of the instrument, which comprises 42 items for self-assessment and eight for peer-assessment, is then shown. This is followed by a presentation and discussion of the findings from first use of the instrument with MNH providers from 12 rural, primary level facilities in each of the three countries. Conclusions It is possible to undertake work of this nature at primary health care level, particularly if the instruments are kept as straightforward as possible and well introduced. However, their development requires very lengthy preparatory periods. The effort needed to adapt such instruments for use in different countries within the region of sub-Saharan Africa should not be underestimated. PMID

  13. Transgressive or Instrumental?

    DEFF Research Database (Denmark)

    Chemi, Tatiana

    2018-01-01

    Contemporary practices that connect the arts with learning are widespread at all level of educational systems and in organisations, but they include very diverse approaches, multiple methods and background values. Regardless of explicit learning benefits, the arts/learning partnerships bring about...... creativity and the other on practices of arts-integration. My final point rests on the belief that the opposition of transgression and instrumentality is a deceiving perspective on the arts, against the background of the aesthetic plurality and hybridity....

  14. Irradiation technology (1). Development of new in-pile instrumentation at JMTR

    International Nuclear Information System (INIS)

    Shibata, Akira; Kimura, Nobuaki; Tanimoto, Masataka; Nakamura, Jinichi; Saito, Takashi; Tsuchiya, Kunihiko

    2012-01-01

    Development of instrumentation which can use under severe accident condition is important issue for the purpose to cope with severe accident at nuclear reactors. And also to improve the quality of irradiation tests data and to increase the reliability of safety management system of reactors, the development of new instrumentation is key issue. JAEA is developing several in-pile instrumentations to conduct irradiation tests at JMTR. This study includes the developments of three new instrumentations and describes the characteristics of the instrumentations. These are ECP sensor, new water level indicator and in-reactor observation system using Cherenkov light. (author)

  15. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2000-01-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised

  16. Calibration methodology for instruments utilized in X radiation beams, diagnostic level

    International Nuclear Information System (INIS)

    Penha, M. da; Potiens, A.; Caldas, L.V.E.

    2004-01-01

    Methodologies for the calibration of diagnostic radiology instruments were established at the Calibration Laboratory of IPEN. The methods may be used in the calibration procedures of survey meters used in radiation protection measurements (scattered radiation), instruments used in direct beams (attenuated and non attenuated beams) and quality control instruments. The established qualities are recommended by the international standards IEC 1267 and ISO 4037-3. Two ionization chambers were used as reference systems, one with a volume of 30 cm 3 for radiation protection measurements, and the other with a volume of 1 cm 3 for direct beam measurements. Both are traceable to the German Primary Laboratory of Physikalisch-Technische Bundesanstalt (PTB). In the case of calibration of quality control instruments, a non-invasive method using the measurement of the spectrum endpoint was established with a portable gamma and X-ray Intertechnique spectrometer system. The methods were applied to survey meters (radiation protection measurements), ionization chambers (direct beam measurements) and k Vp meters (invasive and non-invasive instruments). (Author)

  17. Calibration methodology for instruments utilized in X radiation beams, diagnostic level

    Energy Technology Data Exchange (ETDEWEB)

    Penha, M. da; Potiens, A.; Caldas, L.V.E. [Instituto de Pesquisas Energeticas e Nucleares, Comissao Nacional de Energia Nuclear, Sao Paulo (Brazil)]. E-mail: mppalbu@ipen.br

    2004-07-01

    Methodologies for the calibration of diagnostic radiology instruments were established at the Calibration Laboratory of IPEN. The methods may be used in the calibration procedures of survey meters used in radiation protection measurements (scattered radiation), instruments used in direct beams (attenuated and non attenuated beams) and quality control instruments. The established qualities are recommended by the international standards IEC 1267 and ISO 4037-3. Two ionization chambers were used as reference systems, one with a volume of 30 cm{sup 3} for radiation protection measurements, and the other with a volume of 1 cm{sup 3} for direct beam measurements. Both are traceable to the German Primary Laboratory of Physikalisch-Technische Bundesanstalt (PTB). In the case of calibration of quality control instruments, a non-invasive method using the measurement of the spectrum endpoint was established with a portable gamma and X-ray Intertechnique spectrometer system. The methods were applied to survey meters (radiation protection measurements), ionization chambers (direct beam measurements) and k Vp meters (invasive and non-invasive instruments). (Author)

  18. Functions and Requirements for Automated Liquid Level Gauge Instruments in Single-Shell and Double-Shell Tank Farms

    International Nuclear Information System (INIS)

    CARPENTER, K.E.

    1999-01-01

    This functions and requirements document defines the baseline requirements and criteria for the design, purchase, fabrication, construction, installation, and operation of automated liquid level gauge instruments in the Tank Farms. This document is intended to become the technical baseline for current and future installation, operation and maintenance of automated liquid level gauges in single-shell and double-shell tank farms

  19. Instrumentation for environmental monitoring: biomedical

    International Nuclear Information System (INIS)

    1979-05-01

    An update is presented to Volume four of the six-volume series devoted to a survey of instruments useful for measurements in biomedicine related to environmental research and monitoring. Results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Methods of detection and analysis of gaseous organic pollutants and metals, including Ni and As are presented. Instrument techniques and notes are included on atomic spectrometry and uv and visible absorption instrumentation

  20. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2000-07-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised.

  1. Limit of detection in the presence of instrumental and non-instrumental errors: study of the possible sources of error and application to the analysis of 41 elements at trace levels by inductively coupled plasma-mass spectrometry technique

    International Nuclear Information System (INIS)

    Badocco, Denis; Lavagnini, Irma; Mondin, Andrea; Tapparo, Andrea; Pastore, Paolo

    2015-01-01

    In this paper the detection limit was estimated when signals were affected by two error contributions, namely instrumental errors and operational-non-instrumental errors. The detection limit was theoretically obtained following the hypothesis testing schema implemented with the calibration curve methodology. The experimental calibration design was based on J standards measured I times with non-instrumental errors affecting each standard systematically but randomly among the J levels. A two-component variance regression was performed to determine the calibration curve and to define the detection limit in these conditions. The detection limit values obtained from the calibration at trace levels of 41 elements by ICP-MS resulted larger than those obtainable from a one component variance regression. The role of the reagent impurities on the instrumental errors was ascertained and taken into account. Environmental pollution was studied as source of non-instrumental errors. The environmental pollution role was evaluated by Principal Component Analysis technique (PCA) applied to a series of nine calibrations performed in fourteen months. The influence of the seasonality of the environmental pollution on the detection limit was evidenced for many elements usually present in the urban air particulate. The obtained results clearly indicated the need of using the two-component variance regression approach for the calibration of all the elements usually present in the environment at significant concentration levels. - Highlights: • Limit of detection was obtained considering a two variance component regression. • Calibration data may be affected by instrumental and operational conditions errors. • Calibration model was applied to determine 41 elements at trace level by ICP-MS. • Non instrumental errors were evidenced by PCA analysis

  2. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2002-01-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described

  3. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2002-04-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described.

  4. Extending the Instrumental Record of Sea-Level Change: A 1300-Year Sea-Level Record From Eastern Connecticut

    Science.gov (United States)

    Donnelly, J. P.; Cleary, P.

    2002-12-01

    The instrumental record of sea-level change in the northeastern United States extends back to the early 20th century and at New York City (NYC) extends back to 1856. These tide gauge records indicate that sea level has risen at a rate of 2.5 to 4 mm/year over the last 100-150 years. Geologic evidence of sea-level change in the region over the last 2,000 years indicates rates of sea-level rise of about 1 mm/year or less. The discordance between the instrumental and geologic records is frequently cited as potentially providing evidence that anthropogenic warming of the climate system has resulted in an increase in the rate of sea-level rise. In order to begin to test the hypothesis that acceleration in the rate of sea-level rise has occurred in the last 150 years due to anthropogenic climate warming, accurate and precise information on the timing of the apparent acceleration in sea-level rise are needed. Here we construct a high-resolution relative sea-level record for the past 1350 years by dating basal salt marsh peat samples above a glacial erratic in a western Connecticut salt marsh. Preservation of marsh vegetation remains in the sediment record that has a narrow vertical habitat range at the upper end of the tidal range provides information on past sea levels. { \\it Spartina patens} (marsh hay) and { \\it Juncus gerardi} (black rush) dominate both the modern marsh and their remains are the major constituent of the marsh sediments and occur in the modern marsh between mean high water (MHW) and mean highest high water. We use the elevation distribution of modern plant communities to estimate the relationship of sediment samples to paleo-mean high water. The chronology is based on 15 radiocarbon ages, supplemented by age estimates derived from the horizons of industrial Pb pollution and pollen indicative of European land clearance. Thirteen of the radiocarbon ages and the Pb and pollen data come from samples taken along a contact between marsh peat and a glacial

  5. Progress in instrumentation and control including the man-machine interface

    International Nuclear Information System (INIS)

    Wahlstroem, B.; Pedersen, T.; Neboyan, V.

    1999-01-01

    The paper discusses benefits and difficulties associated with the use of new digital instrumentation and control (I and C) systems for nuclear applications. The rapid development of information technology has not been used to the same extent in the nuclear industry as in conventional industries. The most important reason for this under-representation is a de-facto moratorium for construction of new plants. In old nuclear power plants (NPPs) the new technology is used in modernisation projects and valuable experience has been obtained. The licensing of programmable systems presents new challenges especially for safety systems where a very high integrity is required. The paper discusses various aspects related to the use of the new systems for nuclear applications, it gives references to ongoing work of international organisations and to research that is seen as an effort to solve problems related to implementation of the new systems for nuclear applications. (author)

  6. An Attitude Scale on Individual Instrument and Individual Instrument Course: Validity-Reliability Research

    Science.gov (United States)

    Kuçukosmanoglu, Hayrettin Onur

    2015-01-01

    The main purpose of this study is to develop a scale to determine students' attitude levels on individual instruments and individual instrument courses in instrument training, which is an important dimension of music education, and to conduct a validity-reliability research of the scale that has been developed. The scale consists of 16 items. The…

  7. SMAP Instrument Mechanical System Engineering

    Science.gov (United States)

    Slimko, Eric; French, Richard; Riggs, Benjamin

    2013-01-01

    The Soil Moisture Active Passive (SMAP) mission, scheduled for launch by the end of 2014, is being developed to measure the soil moisture and soil freeze/thaw state on a global scale over a three-year period. The accuracy, resolution, and global coverage of SMAP measurements are invaluable across many science and applications disciplines including hydrology, climate, carbon cycle, and the meteorological, environment, and ecology applications communities. The SMAP observatory is composed of a despun bus and a spinning instrument platform that includes both a deployable 6 meter aperture low structural frequency Astromesh reflector and a spin control system. The instrument section has engendered challenging mechanical system issues associated with the antenna deployment, flexible antenna pointing in the context of a multitude of disturbances, spun section mass properties, spin control system development, and overall integration with the flight system on both mechanical and control system levels. Moreover, the multitude of organizations involved, including two major vendors providing the spin subsystem and reflector boom assembly plus the flight system mechanical and guidance, navigation, and control teams, has led to several unique system engineering challenges. Capturing the key physics associated with the function of the flight system has been challenging due to the many different domains that are applicable. Key interfaces and operational concepts have led to complex negotiations because of the large number of organizations that integrate with the instrument mechanical system. Additionally, the verification and validation concerns associated with the mechanical system have had required far-reaching involvement from both the flight system and other subsystems. The SMAP instrument mechanical systems engineering issues and their solutions are described in this paper.

  8. The Standard, Power, and Color Model of Instrument Combination in Romantic-Era Symphonic Works

    Directory of Open Access Journals (Sweden)

    Randolph Johnson

    2011-08-01

    Full Text Available The Standard, Power, and Color (SPC model describes the nexus between musical instrument combination patterns and expressive goals in music. Instruments within each SPC group tend to attract each other and work as a functional unit to create orchestral gestures. Standard instruments establish a timbral groundwork; Power instruments create contrast through loud dynamic climaxes; and Color instruments catch listeners’ attention by means of their sparing use. Examples within these three groups include violin (Standard, piccolo (Power, and harp (Color. The SPC theory emerges from analyses of nineteenth-century symphonic works. Multidimensional scaling analysis of instrument combination frequencies maps instrument relationships; hierarchical clustering analysis indicates three SPC groups within the map. The SPC characterization is found to be moderately robust through the results of hypothesis testing: (1 Color instruments are included less often in symphonic works; (2 when Color instruments are included, they perform less often than the average instrument; and (3 Color and non-Color instruments have equal numbers of solo occurrences. Additionally, (4 Power instruments are positively associated with louder dynamic levels; and (5 when Power instruments are present in the musical texture, the pitch range spanned by the entire orchestra does not become more extreme.

  9. Trends in instrumentation for environmental radiation measurements at Los Alamos Scientific Laboratory

    International Nuclear Information System (INIS)

    Hiebert, R.D.; Wolf, M.A.

    1980-01-01

    Recent instruments developed to fulfill radiation monitoring needs at Los Alamos Scientific Laboratory are described. Laboratory instruments that measure tritium gas effluents alone, or in the presence of activated air from D-T fusion reactors are discussed. Fully portable systems for gamma, x-ray, and alpha analyses in the field are described. Also included are descriptions of survey instruments that measure low levels of transuranic contaminants and that measure pulsed-neutron dose rates

  10. Advances in SPECT Instrumentation (Including Small Animal Scanners). Chapter 4

    International Nuclear Information System (INIS)

    Di Domenico, G.; Zavattini, G.

    2009-01-01

    Fundamental major efforts have been devoted to the development of positron emission tomography (PET) imaging modality over the last few decades. Recently, a novel surge of interest in single photon emission computed tomography (SPECT) technology has occurred, particularly after the introduction of the hybrid SPECT-CT imaging system. This has led to a flourishing of investigations in new types of detectors and collimators, and to more accurate refinement of reconstruction algorithms. Along with SPECT-CT, new, fast gamma cameras have been developed for dedicated cardiac imaging. The existing gap between PET and SPECT in sensitivity and spatial resolution is progressively decreasing, and this trend is particularly apparent in the field of small animal imaging where the most important advances have been reported in SPECT tomographs. An outline of the basic features of SPECT technology, and of recent developments in SPECT instrumentation for both clinical applications and basic biological research on animal models is described. (author)

  11. Do Current Recommendations for Upper Instrumented Vertebra Predict Shoulder Imbalance? An Attempted Validation of Level Selection for Adolescent Idiopathic Scoliosis.

    Science.gov (United States)

    Bjerke, Benjamin T; Cheung, Zoe B; Shifflett, Grant D; Iyer, Sravisht; Derman, Peter B; Cunningham, Matthew E

    2015-10-01

    Shoulder balance for adolescent idiopathic scoliosis (AIS) patients is associated with patient satisfaction and self-image. However, few validated systems exist for selecting the upper instrumented vertebra (UIV) post-surgical shoulder balance. The purpose is to examine the existing UIV selection criteria and correlate with post-surgical shoulder balance in AIS patients. Patients who underwent spinal fusion at age 10-18 years for AIS over a 6-year period were reviewed. All patients with a minimum of 1-year radiographic follow-up were included. Imbalance was determined to be radiographic shoulder height |RSH| ≥ 15 mm at latest follow-up. Three UIV selection methods were considered: Lenke, Ilharreborde, and Trobisch. A recommended UIV was determined using each method from pre-surgical radiographs. The recommended UIV for each method was compared to the actual UIV instrumented for all three methods; concordance between these levels was defined as "Correct" UIV selection, and discordance was defined as "Incorrect" selection. One hundred seventy-one patients were included with 2.3 ± 1.1 year follow-up. For all methods, "Correct" UIV selection resulted in more shoulder imbalance than "Incorrect" UIV selection. Overall shoulder imbalance incidence was improved from 31.0% (53/171) to 15.2% (26/171). New shoulder imbalance incidence for patients with previously level shoulders was 8.8%. We could not identify a set of UIV selection criteria that accurately predicted post-surgical shoulder balance. Further validated measures are needed in this area. The complexity of proximal thoracic curve correction is underscored in a case example, where shoulder imbalance occurred despite "Correct" UIV selection by all methods.

  12. Nano-level instrumentation for analyzing the dynamic accuracy of a rolling element bearing

    International Nuclear Information System (INIS)

    Yang, Z.; Hong, J.; Zhang, J.; Wang, M. Y.; Zhu, Y.

    2013-01-01

    The rotational performance of high-precision rolling bearings is fundamental to the overall accuracy of complex mechanical systems. A nano-level instrument to analyze rotational accuracy of high-precision bearings of machine tools under working conditions was developed. In this instrument, a high-precision (error motion < 0.15 μm) and high-stiffness (2600 N axial loading capacity) aerostatic spindle was applied to spin the test bearing. Operating conditions could be simulated effectively because of the large axial loading capacity. An air-cylinder, controlled by a proportional pressure regulator, was applied to drive an air-bearing subjected to non-contact and precise loaded axial forces. The measurement results on axial loading and rotation constraint with five remaining degrees of freedom were completely unconstrained and uninfluenced by the instrument's structure. Dual capacity displacement sensors with 10 nm resolution were applied to measure the error motion of the spindle using a double-probe error separation method. This enabled the separation of the spindle's error motion from the measurement results of the test bearing which were measured using two orthogonal laser displacement sensors with 5 nm resolution. Finally, a Lissajous figure was used to evaluate the non-repetitive run-out (NRRO) of the bearing at different axial forces and speeds. The measurement results at various axial loadings and speeds showed the standard deviations of the measurements’ repeatability and accuracy were less than 1% and 2%. Future studies will analyze the relationship between geometrical errors and NRRO, such as the ball diameter differences of and the geometrical errors in the grooves of rings

  13. Adjacent segment disease in degenerative pathologies with posterior instrumentation

    Directory of Open Access Journals (Sweden)

    Ana Guadalupe Ramírez Olvera

    2015-03-01

    Full Text Available OBJECTIVE: To establish the real incidence of adjacent segment disease after fusion, and to identify the levels and predisposing factors for the pathology, as well as the functional results. METHODS: a retrospective case series study with level of evidence IIB, in a sample of 179 patients diagnosed with stenosis of the lumbar spine, spondylolisthesis and degenerative scoliosis, submitted to surgery in the period 2005 to December 2013, with posterior instrumentation and posterolateral fusion, with follow-up from 2007 until May 2014, in which the symptomology and radiographic findings were evaluated, to establish the diagnosis and treatment. RESULTS: the study included 179 patients diagnosed with stenosis of the lumbar spine (n=116, isthmic and degenerative spondylolisthesis (n=50 and degenerative scoliosis (n=13; during the study, 20 cases of adjacent level segment were identified, 80% of which were treated surgically with extension of the instrumentation, while 20% were treated conservatively with NSAIDs and therapeutic blocks. CONCLUSION: An incidence of 11% was found, with an average of 3.25 years in diagnosis and treatment, a prevalence of females and diagnosis of stenosis of the lumbar canal on posterior instrumentation, a predominance of levels L4-L5; 80% were treated with extension of the instrumentation. The complications were persistent radiculopathy, infection of the surgical wound, and one death due to causes not related to the lumbar pathology.

  14. Reliability of patient specific instrumentation in total knee arthroplasty.

    Science.gov (United States)

    Jennart, Harold; Ngo Yamben, Marie-Ange; Kyriakidis, Theofylaktos; Zorman, David

    2015-12-01

    The aim of this study was to compare the precision between Patient Specific Instrumentation (PSI) and Conventional Instrumentation (CI) as determined intra-operatively by a pinless navigation system. Eighty patients were included in this prospective comparative study and they were divided into two homogeneous groups. We defined an original score from 6 to 30 points to evaluate the accuracy of the position of the cutting guides. This score is based on 6 objective criteria. The analysis indicated that PSI was not superior to conventional instrumentation in the overall score (p = 0.949). Moreover, no statistically significant difference was observed for any individual criteria of our score. Level of evidence II.

  15. Health physics instrument manual

    International Nuclear Information System (INIS)

    Gupton, E.D.

    1978-08-01

    The purpose of this manual is to provide apprentice health physics surveyors and other operating groups not directly concerned with radiation detection instruments a working knowledge of the radiation detection and measuring instruments in use at the Laboratory. The characteristics and applications of the instruments are given. Portable instruments, stationary instruments, personnel monitoring instruments, sample counters, and miscellaneous instruments are described. Also, information sheets on calibration sources, procedures, and devices are included. Gamma sources, beta sources, alpha sources, neutron sources, special sources, a gamma calibration device for badge dosimeters, and a calibration device for ionization chambers are described

  16. Labour Standards and Trade: In Search of Impact and Alternative Instruments

    Directory of Open Access Journals (Sweden)

    Jan Orbie

    2017-12-01

    Full Text Available Labour standards have become an almost routine feature of trade agreements. However, we have little knowledge about whether this linkage is effective; both in absolute terms but also in comparison to other instruments that promote labour standards on a global level. Such alternative instruments include public-private agreements, value chain management and procurement policies. The articles in this thematic issue will provide insights that further the debate on the effectiveness of the connection between labour rights and international trade, looking at both ‘traditional’ trade agreements and ‘alternative’ instruments.

  17. Recent advances in radiation protection instrumentation

    International Nuclear Information System (INIS)

    Babu, D.A.R.

    2012-01-01

    Radiation protection instrumentation plays very important role in radiation protection and surveillance programme. Radiation detector, which appears at the frontal end of the instrument, is an essential component of these instruments. The instrumental requirement of protection level radiation monitoring is different from conventional radiation measuring instruments. Present paper discusses the new type of nuclear radiation detectors, new protection level instruments and associated electronic modules for various applications. Occupational exposure to ionizing radiation can occur in a range of industries, such as nuclear power plants; mining and milling; medical institutions; educational and research establishments; and nuclear fuel cycle facilities. Adequate radiation protection to workers is essential for the safe and acceptable use of radioactive materials for different applications. The radiation exposures to the individual radiation workers and records of their cumulative radiation doses need to be routinely monitored and recorded

  18. Operator Actions Within a Safety Instrumented Function

    International Nuclear Information System (INIS)

    Suttinger, L.T.

    2002-01-01

    This paper presents an overview of the factors that should be considered when crediting operator action for performing a safety function or being a part of the process of enabling a safety function. Criteria for evaluating operator action, such as required time response and operator training among others, are discussed. The paper will address these and other factors that should be considered when determining the reliability of the operator to respond and perform his/her part of the safety function. The entire safety function includes the operator and the reliability of the instrumented system that provides the alarm or indication, the final control element, and support systems. The integration of the operator performance with the hardware safety availability, including the effects of the supporting systems is discussed. The analysis of these factors will provide the justification for the amount of risk reduction or safety integrity level that can be credited for the Safety Instrumented Function (SIF), including operator action

  19. Hanford double shell tank corrosion monitoring instrument trees

    International Nuclear Information System (INIS)

    Nelson, J.L.

    1995-03-01

    High-level nuclear wastes at the Hanford site are stored underground in carbon steel double-shell and single-shell tanks - (DSTs and SSTS). Westinghouse Hanford Company is considering installation of a prototype corrosion monitoring instrument tree in at least one DST in the summer of 1995. The instrument tree will have the ability to detect and discriminate between uniform corrosion, stress corrosion cracking (SCC), and pitting. Additional instrument trees will follow in later years. Proof-of-technology testing is currently underway for the use of commercially available electric field pattern (EFP) analysis and electrochemical noise (EN) corrosion monitoring equipment. Creative use and combinations of other existing technologies is also being considered. Successful demonstration of these technologies will be followed by the development of a Hanford specific instrument tree. The first instrument tree will incorporate one of these technologies. Subsequent trees may include both technologies, as well as a more standard assembly of corrosion coupons. Successful development of these trees will allow their application to single shell tanks and the transfer of technology to other U.S. Department of Energy (DOE) sites

  20. 77 FR 37409 - Request for Domains, Instruments, and Measures for Development of a Standardized Instrument for...

    Science.gov (United States)

    2012-06-21

    ... experience as well. On both issues, CMS is interested in instruments and items which can measure quality of... Measures for Development of a Standardized Instrument for Use in Public Reporting of Enrollee Satisfaction..., communication, coordination of care, customer service), instruments, and measures for measuring the level of...

  1. Biomechanical comparison of force levels in spinal instrumentation using monoaxial versus multi degree of freedom postloading pedicle screws.

    Science.gov (United States)

    Wang, Xiaoyu; Aubin, Carl-Eric; Crandall, Dennis; Labelle, Hubert

    2011-01-15

    biomechanical analysis and simulations of correction mechanisms and force levels during scoliosis instrumentation using two types of pedicle screws and primary correction maneuvers. to biomechanically analyze implant-vertebra and inter-vertebral forces during scoliosis correction, to address the hypothesis that multi degree of freedom (MDOF) postloading screws with a direct incremental segmental translation (DIST) correction technique significantly reduce the loads as compared with monoaxial (MA) tulip-top design screws with a rod derotation technique (RDT). MA screw is widely used for spinal instrumentation. The MDOF screw was introduced as a refinement of the correction philosophy based on multiaxial screws. The kinematics of the MDOF construct is fundamentally different and offers more degrees of freedom than that of the MA construct; however, a systematic comparison of their biomechanics has not been done so far. a biomechanical model was developed to simulate the instrumentation of six scoliotic patients, first with the MDOF screws and DIST. Then, the instrumentation with MA screws and RDT was simulated using the same cases. Thirty more simulations were done to study the force-level sensitivity to small implant placement variation. there was a small average difference of 7°, 5°, and 4° between the two simulated systems for the computed main thoracic Cobb angle, kyphosis, and apical axial rotation, respectively. On average, the mean, standard deviation (SD), and maximum values of the implant-vertebra forces for MDOF screws were 56%, 59%, and 59%, respectively, lower than those for the MA screws, while the intervertebral forces for the MDOF screws were 31%, 37%, and 36% lower, respectively. Under the same set of random small implant placement changes, the mean, SD, and maximum values of implant-vertebra force magnitude changes for MDOF screws were 93%, 92%, and 95%, respectively, lower than those for MA screws. with MDOF screws and DIST, it is possible for

  2. Patient-Reported Outcome and Quality of Life Instruments Database (PROQOLID: Frequently asked questions

    Directory of Open Access Journals (Sweden)

    Perrier Laure-Lou

    2005-03-01

    Full Text Available Abstract The exponential development of Patient-Reported Outcomes (PRO measures in clinical research has led to the creation of the Patient-Reported Outcome and Quality of Life Instruments Database (PROQOLID to facilitate the selection process of PRO measures in clinical research. The project was initiated by Mapi Research Trust in Lyon, France. Initially called QOLID (Quality of Life Instruments Database, the project's purpose was to provide all those involved in health care evaluation with a comprehensive and unique source of information on PRO and HRQOL measures available through the Internet. PROQOLID currently describes more than 470 PRO instruments in a structured format. It is available in two levels, non-subscribers and subscribers, at http://www.proqolid.org. The first level is free of charge and contains 14 categories of basic useful information on the instruments (e.g. author, objective, original language, list of existing translations, etc.. The second level provides significantly more information about the instruments. It includes review copies of over 350 original instruments, 120 user manuals and 350 translations. Most are available in PDF format. This level is only accessible to annual subscribers. PROQOLID is updated in close collaboration with the instruments' authors on a regular basis. Fifty or more new instruments are added to the database annually. Today, all of the major pharmaceutical companies, prestigious institutions (such as the FDA, the NIH's National Cancer Institute, the U.S. Veterans Administration, dozens of universities, public institutions and researchers subscribe to PROQOLID on a yearly basis. More than 800 users per day routinely visit the database.

  3. Pancreatitis Quality of Life Instrument: Development of a new instrument

    Directory of Open Access Journals (Sweden)

    Wahid Wassef

    2014-02-01

    Full Text Available Objectives: The goal of this project was to develop the first disease-specific instrument for the evaluation of quality of life in chronic pancreatitis. Methods: Focus groups and interview sessions were conducted, with chronic pancreatitis patients, to identify items felt to impact quality of life which were subsequently formatted into a paper-and-pencil instrument. This instrument was used to conduct an online survey by an expert panel of pancreatologists to evaluate its content validity. Finally, the modified instrument was presented to patients during precognitive testing interviews to evaluate its clarity and appropriateness. Results: In total, 10 patients were enrolled in the focus groups and interview sessions where they identified 50 items. Once redundant items were removed, the 40 remaining items were made into a paper-and-pencil instrument referred to as the Pancreatitis Quality of Life Instrument. Through the processes of content validation and precognitive testing, the number of items in the instrument was reduced to 24. Conclusions: This marks the development of the first disease-specific instrument to evaluate quality of life in chronic pancreatitis. It includes unique features not found in generic instruments (economic factors, stigma, and spiritual factors. Although this marks a giant step forward, psychometric evaluation is still needed prior to its clinical use.

  4. Design requirements for the SWIFT instrument

    International Nuclear Information System (INIS)

    Rahnama, P; McDade, I; Shepherd, G; Gault, W

    2013-01-01

    The Stratospheric Wind Interferometer for Transport studies (SWIFT) instrument is a proposed limb-viewing satellite instrument that employs the method of Doppler Michelson interferometry to measure stratospheric wind velocities and ozone densities in the altitude range of 15–45 km. The values of the main instrument parameters including filter system parameters and Michelson interferometer parameters are derived using simulations and analyses. The system design requirements for the instrument and spacecraft are presented and discussed. Some of the retrieval-imposed design requirements are also discussed. Critical design issues are identified. The design optimization process is described. The sensitivity of wind measurements to instrument characteristics is investigated including the impact on critical design issues. Using sensitivity analyses, the instrument parameters were iteratively optimized in order to meet the science objectives. It is shown that wind measurements are sensitive to the thermal sensitivity of the instrument components, especially the narrow filter and the Michelson interferometer. The optimized values of the main system parameters including Michelson interferometer optical path difference, instrument visibility, instrument responsivity and knowledge of spacecraft velocity are reported. This work also shows that the filter thermal drift and the Michelson thermal drift are two main technical risks. (paper)

  5. Instrument evaluation no.14: Wallac laboratory contamination meter RD 11

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1979-01-01

    An instrument for measuring low level contamination and consisting of a detachable Geiger-Muller tube probe, connected to a rate meter by a coiled extensible tube is described. Facilities and controls, performance, electrical, environmental and mechanical characteristics are included. (UK)

  6. Instrument comparison for Aerosolized Titanium Dioxide

    Science.gov (United States)

    Ranpara, Anand

    Recent toxicological studies have shown that the surface area of ultrafine particles (UFP i.e., particles with diameters less than 0.1 micrometer) has a stronger correlation with adverse health effects than does mass of these particles. Ultrafine titanium dioxide (TiO2) particles are widely used in industry, and their use is associated with adverse health outcomes, such as micro vascular dysfunctions and pulmonary damages. The primary aim of this experimental study was to compare a variety of laboratory and industrial hygiene (IH) field study instruments all measuring the same aerosolized TiO2. The study also observed intra-instrument variability between measurements made by two apparently identical devices of the same type of instrument placed side-by-side. The types of instruments studied were (1) DustTrak(TM) DRX, (2) Personal Data RAMs(TM) (PDR), (3) GRIMM, (4) Diffusion charger (DC) and (5) Scanning Mobility Particle Sizer (SMPS). Two devices of each of the four IH field study instrument types were used to measure six levels of mass concentration of fine and ultrafine TiO2 aerosols in controlled chamber tests. Metrics evaluated included real-time mass, active surface area and number/geometric surface area distributions, and off-line gravimetric mass and morphology on filters. DustTrak(TM) DRXs and PDRs were used for mass concentration measurements. DCs were used for active surface area concentration measurements. GRIMMs were used for number concentration measurements. SMPS was used for inter-instrument comparisons of surface area and number concentrations. The results indicated that two apparently identical devices of each DRX and PDR were statistically not different with each other for all the trials of both the sizes of powder (p < 5%). Mean difference between mass concentrations measured by two DustTrak DRX devices was smaller than that measured by two PDR devices. DustTrak DRX measurements were closer to the reference method, gravimetric mass concentration

  7. Minimal Function Graphs are not Instrumented

    DEFF Research Database (Denmark)

    Mycroft, Alan; Rosendahl, Mads

    1992-01-01

    The minimal function graph semantics of Jones and Mycroft is a standard denotational semantics modified to include only `reachable' parts of a program. We show that it may be expressed directly in terms of the standard semantics without the need for instrumentation at the expression level and......, in doing so, bring out a connection with strictness. This also makes it possible to prove a stronger theorem of correctness for the minimal function graph semantics....

  8. Software-Enabled Modular Instrumentation Systems

    NARCIS (Netherlands)

    Soijer, M.W.

    2003-01-01

    Like most other types of instrumentation systems, flight test instrumentation is not produced in series; its development is a one-time achievement by a test department. With the introduction of powerful digital computers, instrumentation systems have included data analysis tasks that were previously

  9. Robust Instrumentation[Water treatment for power plant]; Robust Instrumentering

    Energy Technology Data Exchange (ETDEWEB)

    Wik, Anders [Vattenfall Utveckling AB, Stockholm (Sweden)

    2003-08-01

    Cementa Slite Power Station is a heat recovery steam generator (HRSG) with moderate steam data; 3.0 MPa and 420 deg C. The heat is recovered from Cementa, a cement industry, without any usage of auxiliary fuel. The Power station commenced operation in 2001. The layout of the plant is unusual, there are no similar in Sweden and very few world-wide, so the operational experiences are limited. In connection with the commissioning of the power plant a R and D project was identified with the objective to minimise the manpower needed for chemistry management of the plant. The lean chemistry management is based on robust instrumentation and chemical-free water treatment plant. The concept with robust instrumentation consists of the following components; choice of on-line instrumentation with a minimum of O and M and a chemical-free water treatment. The parameters are specific conductivity, cation conductivity, oxygen and pH. In addition to that, two fairly new on-line instruments were included; corrosion monitors and differential pH calculated from specific and cation conductivity. The chemical-free water treatment plant consists of softening, reverse osmosis and electro-deionisation. The operational experience shows that the cycle chemistry is not within the guidelines due to major problems with the operation of the power plant. These problems have made it impossible to reach steady state and thereby not viable to fully verify and validate the concept with robust instrumentation. From readings on the panel of the online analysers some conclusions may be drawn, e.g. the differential pH measurements have fulfilled the expectations. The other on-line analysers have been working satisfactorily apart from contamination with turbine oil, which has been noticed at least twice. The corrosion monitors seem to be working but the lack of trend curves from the mainframe computer system makes it hard to draw any clear conclusions. The chemical-free water treatment has met all

  10. Seabrook Station Level 2 PRA Update to Include Accident Management

    International Nuclear Information System (INIS)

    Lutz, Robert; Lucci, Melissa; Kiper, Kenneth; Henry, Robert

    2006-01-01

    A ground-breaking study was recently completed as part of the Seabrook Level 2 PRA update. This study updates the post-core damage phenomena to be consistent with the most recent information and includes accident management activities that should be modeled in the Level 2 PRA. Overall, the result is a Level 2 PRA that fully meets the requirements of the ASME PRA Standard with respect to modeling accident management in the LERF assessment and NRC requirements in Regulatory Guide 1.174 for considering late containment failures. This technical paper deals only with the incorporation of operator actions into the Level 2 PRA based on a comprehensive study of the Seabrook Station accident response procedures and guidance. The paper describes the process used to identify the key operator actions that can influence the Level 2 PRA results and the development of success criteria for these key operator actions. This addresses a key requirement of the ASME PRA Standard for considering SAMG. An important benefit of this assessment was the identification of Seabrook specific accident management insights that can be fed back into the Seabrook Station accident management procedures and guidance or the training provided to plant personnel for these procedures and guidance. (authors)

  11. Jones' instrument technology

    CERN Document Server

    Jones, Ernest Beachcroft; Kingham, Edward G; Radnai, Rudolf

    1985-01-01

    Jones' Instrument Technology, Volume 5: Automatic Instruments and Measuring Systems deals with general trends in automatic instruments and measuring systems. Specific examples are provided to illustrate the principles of such devices. A brief review of a considerable number of standards is undertaken, with emphasis on the IEC625 Interface System. Other relevant standards are reviewed, including the interface and backplane bus standards. This volume is comprised of seven chapters and begins with a short introduction to the principles of automatic measurements, classification of measuring system

  12. Development of a nursing workload measurement instrument in burn care

    NARCIS (Netherlands)

    Jong, A.E.; Leeman, J.; Middelkoop, E.

    2009-01-01

    Existing workload measurement instruments fail to represent specific nursing activities in a setting where patients are characterized by a diversity of cause, location, extent and depth of burns, of age and of history. They also do not include educational levels and appropriate time standards. The

  13. Decoupling Solar Variability and Instrument Trends Using the Multiple Same-Irradiance-Level (MuSIL) Analysis Technique

    Science.gov (United States)

    Woods, Thomas N.; Eparvier, Francis G.; Harder, Jerald; Snow, Martin

    2018-05-01

    The solar spectral irradiance (SSI) dataset is a key record for studying and understanding the energetics and radiation balance in Earth's environment. Understanding the long-term variations of the SSI over timescales of the 11-year solar activity cycle and longer is critical for many Sun-Earth research topics. Satellite measurements of the SSI have been made since the 1970s, most of them in the ultraviolet, but recently also in the visible and near-infrared. A limiting factor for the accuracy of previous solar variability results is the uncertainties for the instrument degradation corrections, which need fairly large corrections relative to the amount of solar cycle variability at some wavelengths. The primary objective of this investigation has been to separate out solar cycle variability and any residual uncorrected instrumental trends in the SSI measurements from the Solar Radiation and Climate Experiment (SORCE) mission and the Thermosphere, Mesosphere, Ionosphere, Energetic, and Dynamics (TIMED) mission. A new technique called the Multiple Same-Irradiance-Level (MuSIL) analysis has been developed, which examines an SSI time series at different levels of solar activity to provide long-term trends in an SSI record, and the most common result is a downward trend that most likely stems from uncorrected instrument degradation. This technique has been applied to each wavelength in the SSI records from SORCE (2003 - present) and TIMED (2002 - present) to provide new solar cycle variability results between 27 nm and 1600 nm with a resolution of about 1 nm at most wavelengths. This technique, which was validated with the highly accurate total solar irradiance (TSI) record, has an estimated relative uncertainty of about 5% of the measured solar cycle variability. The MuSIL results are further validated with the comparison of the new solar cycle variability results from different solar cycles.

  14. Soil monitoring instrumentation

    International Nuclear Information System (INIS)

    Umbarger, C.J.

    1981-01-01

    The Los Alamos Scientific Laboratory (LASL) has an extensive program for the development of nondestructive assay instrumentation for the quantitative analysis of transuranic (TRU) materials found in bulk solid wastes generated by Department of Energy facilities and by the commercial nuclear power industry. Included are wastes generated in decontamination and decommissioning of outdated nuclear facilities, as well as from old waste-burial-ground exhumation programs. The assay instrumentation is designed to have detection limits below 10 nCi/g wherever practicable. The assay instrumentation that is applied specifically to soil monitoring is discussed

  15. Design, development, and testing of the DCT Cassegrain instrument support assembly

    Science.gov (United States)

    Bida, Thomas A.; Dunham, Edward W.; Nye, Ralph A.; Chylek, Tomas; Oliver, Richard C.

    2012-09-01

    The 4.3m Discovery Channel Telescope delivers an f/6.1 unvignetted 0.5° field to its RC focal plane. In order to support guiding, wavefront sensing, and instrument installations, a Cassegrain instrument support assembly has been developed which includes a facility guider and wavefront sensor package (GWAVES) and multiple interfaces for instrumentation. A 2-element, all-spherical, fused-silica corrector compensates for field curvature and astigmatism over the 0.5° FOV, while reducing ghost pupil reflections to minimal levels. Dual roving GWAVES camera probes pick off stars in the outer annulus of the corrected field, providing simultaneous guiding and wavefront sensing for telescope operations. The instrument cube supports 5 co-mounted instruments with rapid feed selection via deployable fold mirrors. The corrected beam passes through a dual filter wheel before imaging with the 6K x 6K single CCD of the Large Monolithic Imager (LMI). We describe key development strategies for the DCT Cassegrain instrument assembly and GWAVES, including construction of a prime focus test assembly with wavefront sensor utilized in fall 2011 to begin characterization of the DCT primary mirror support. We also report on 2012 on-sky test results of wavefront sensing, guiding, and imaging with the integrated Cassegrain cube.

  16. Design of a Versatile and Low Cost μVolt Level A to D Conversion System for Use in Medical Instrumentation Applications

    Directory of Open Access Journals (Sweden)

    Neil Robinson

    2008-10-01

    Full Text Available Modern medical facilities place considerable reliance on electronic instrumentation for purposes of calibration and monitoring of therapeutic processes, many of which employ electrical and electronic apparatus that itself generates considerable levels of interference in the form of background electromagnetic radiation (EMR. Additionally diverse ambient conditions in the clinical environment such as uncontrolled temperature, humidity, noise, and vibration place added stress on sensitive instrumentation. In order to obtain accurate, repeatable, and reliable data in such environments, instrumentation used must be largely immune to these factors. Analogue instrumentation is particularly susceptible to unstable environmental conditions. Sensors typically output an analogue current or voltage and it can be demonstrated that considerable overall benefit to the measuring process would result if sensor outputs could be converted to a robust digital format at the earliest possible stage. A practical and low cost system for A to D conversion at μVolt signal levels is described in this work. It has been successfully employed in portable radiation dosimetry instrumentation and used under diverse clinical conditions and it affords an improvement in signal resolution in excess of an order of magnitude over commonly used analogue techniques.

  17. Radiation protection instrument 1993

    International Nuclear Information System (INIS)

    1993-04-01

    The Radiation Protection Instrument, 1993 (Legislative Instrument 1559) prescribes the powers and functions of the Radiation Protection Board established under the Ghana Atomic Energy Commission by the Atomic Energy Commission (Amendment) Law, 1993 (P.N.D.C. Law 308). Also included in the Legislative Instrument are schedules on control and use of ionising radiation and radiation sources as well as procedures for notification, licensing and inspection of ionising radiation facilities. (EAA)

  18. Recent developments in nuclear instruments

    International Nuclear Information System (INIS)

    Vaidya, P.P.

    2004-01-01

    Full text : Nuclear Instrumentation is a field of vital importance for DAE. It has important applications in many areas of interest such as Reactor Monitoring and control, Accelerator based research, Laser and nuclear physics experiments, Health and environmental monitoring, Astrophysics experiments etc. It is a specialized field involving expertise in detection of radioactivity down to the level of few events per minute as well as processing and analysis of signals which can be as small as few hundred micro volts embedded in noise. Some applications involve digitizing and processing these signals with 0.001% accuracy and timing accuracies of a fraction of nano sec. Rapid developments in semiconductor related technologies have influenced the field of nuclear instrumentation. Development of FPGA's and ASIC's have made it possible to develop miniaturized smart and portable instruments for field applications. Advancements in field of computers, communications and various field buses have been successfully utilized for smart, portable and DSP based instrumentation. Smart sensor with detector and front-end electronics on a single silicon chip is now a reality. These instruments are also made intelligent by addition of fuzzy logic, artificial neural networks and expert systems. Electronics Division of BARC has made significant contribution to the field of nuclear instrumentation to achieve self-reliance in this area. This has also led to development of several new methods, which have been published in international journals and appreciated worldwide. As a step towards achieving complete self-reliance a programme for development of FPGA's, HMC's and ASIC's has been undertaken and is being followed with special emphasis. This also includes development of detector and front- end electronics on a single chip. This talk brings out details of these developments and describes the 'state of art' work done in India

  19. Analysis on detection accuracy of binocular photoelectric instrument optical axis parallelism digital calibration instrument

    Science.gov (United States)

    Ying, Jia-ju; Yin, Jian-ling; Wu, Dong-sheng; Liu, Jie; Chen, Yu-dan

    2017-11-01

    Low-light level night vision device and thermal infrared imaging binocular photoelectric instrument are used widely. The maladjustment of binocular instrument ocular axises parallelism will cause the observer the symptom such as dizziness, nausea, when use for a long time. Binocular photoelectric equipment digital calibration instrument is developed for detecting ocular axises parallelism. And the quantitative value of optical axis deviation can be quantitatively measured. As a testing instrument, the precision must be much higher than the standard of test instrument. Analyzes the factors that influence the accuracy of detection. Factors exist in each testing process link which affect the precision of the detecting instrument. They can be divided into two categories, one category is factors which directly affect the position of reticle image, the other category is factors which affect the calculation the center of reticle image. And the Synthesize error is calculated out. And further distribute the errors reasonably to ensure the accuracy of calibration instruments.

  20. Weather Instruments.

    Science.gov (United States)

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    This booklet presents some activities to measure various weather phenomena. Directions for constructing a weather station are included. Instruments including rain gauges, thermometers, wind vanes, wind speed devices, humidity devices, barometers, atmospheric observations, a dustfall jar, sticky-tape can, detection of gases in the air, and pH of…

  1. The contextual effects of social capital on health: a cross-national instrumental variable analysis.

    Science.gov (United States)

    Kim, Daniel; Baum, Christopher F; Ganz, Michael L; Subramanian, S V; Kawachi, Ichiro

    2011-12-01

    Past research on the associations between area-level/contextual social capital and health has produced conflicting evidence. However, interpreting this rapidly growing literature is difficult because estimates using conventional regression are prone to major sources of bias including residual confounding and reverse causation. Instrumental variable (IV) analysis can reduce such bias. Using data on up to 167,344 adults in 64 nations in the European and World Values Surveys and applying IV and ordinary least squares (OLS) regression, we estimated the contextual effects of country-level social trust on individual self-rated health. We further explored whether these associations varied by gender and individual levels of trust. Using OLS regression, we found higher average country-level trust to be associated with better self-rated health in both women and men. Instrumental variable analysis yielded qualitatively similar results, although the estimates were more than double in size in both sexes when country population density and corruption were used as instruments. The estimated health effects of raising the percentage of a country's population that trusts others by 10 percentage points were at least as large as the estimated health effects of an individual developing trust in others. These findings were robust to alternative model specifications and instruments. Conventional regression and to a lesser extent IV analysis suggested that these associations are more salient in women and in women reporting social trust. In a large cross-national study, our findings, including those using instrumental variables, support the presence of beneficial effects of higher country-level trust on self-rated health. Previous findings for contextual social capital using traditional regression may have underestimated the true associations. Given the close linkages between self-rated health and all-cause mortality, the public health gains from raising social capital within and across

  2. netherland hydrological modeling instrument

    Science.gov (United States)

    Hoogewoud, J. C.; de Lange, W. J.; Veldhuizen, A.; Prinsen, G.

    2012-04-01

    Netherlands Hydrological Modeling Instrument A decision support system for water basin management. J.C. Hoogewoud , W.J. de Lange ,A. Veldhuizen , G. Prinsen , The Netherlands Hydrological modeling Instrument (NHI) is the center point of a framework of models, to coherently model the hydrological system and the multitude of functions it supports. Dutch hydrological institutes Deltares, Alterra, Netherlands Environmental Assessment Agency, RWS Waterdienst, STOWA and Vewin are cooperating in enhancing the NHI for adequate decision support. The instrument is used by three different ministries involved in national water policy matters, for instance the WFD, drought management, manure policy and climate change issues. The basis of the modeling instrument is a state-of-the-art on-line coupling of the groundwater system (MODFLOW), the unsaturated zone (metaSWAP) and the surface water system (MOZART-DM). It brings together hydro(geo)logical processes from the column to the basin scale, ranging from 250x250m plots to the river Rhine and includes salt water flow. The NHI is validated with an eight year run (1998-2006) with dry and wet periods. For this run different parts of the hydrology have been compared with measurements. For instance, water demands in dry periods (e.g. for irrigation), discharges at outlets, groundwater levels and evaporation. A validation alone is not enough to get support from stakeholders. Involvement from stakeholders in the modeling process is needed. There fore to gain sufficient support and trust in the instrument on different (policy) levels a couple of actions have been taken: 1. a transparent evaluation of modeling-results has been set up 2. an extensive program is running to cooperate with regional waterboards and suppliers of drinking water in improving the NHI 3. sharing (hydrological) data via newly setup Modeling Database for local and national models 4. Enhancing the NHI with "local" information. The NHI is and has been used for many

  3. The neutron instrument simulation package, NISP

    International Nuclear Information System (INIS)

    Seeger, P.A.; Daemen, L.L.

    2004-01-01

    The Neutron Instrument Simulation Package (NISP) performs complete source-to-detector simulations of neutron instruments, including neutrons that do not follow the expected path. The original user interface (MC( ) Web) is a web-based application, http://strider.lansce.lanl.gov/NISP/Welcome.html. This report describes in detail the newer standalone Windows version, NISP( ) Win. Instruments are assembled from menu-selected elements, including neutron sources, collimation and transport elements, samples, analyzers, and detectors. Magnetic field regions may also be specified for the propagation of polarized neutrons including spin precession. Either interface writes a geometry file that is used as input to the Monte Carlo engine (MC( ) Run) in the user's computer. Both the interface and the engine rely on a subroutine library, MCLIB. The package is completely open source. New features include capillary optics, temperature dependence of Al and Be, revised source files for ISIS, and visualization of neutron trajectories at run time. Also, a single-crystal sample type has been successfully imported from McStas (with more generalized geometry), demonstrating the capability of including algorithms from other sources, and NISP( ) Win may render the instrument in a virtual reality file. Results are shown for two instruments under development.

  4. Nuclear instrumentation for research reactors

    International Nuclear Information System (INIS)

    Hofer, Carlos G.; Pita, Antonio; Verrastro, Claudio A.; Maino, Eduardo J.

    1997-01-01

    The nuclear instrumentation for research reactors in Argentina was developed in 70'. A gradual modernization of all the nuclear instrumentation is planned. It includes start-up and power range instrumentation, as well as field monitors, clamp, scram and rod movement control logic. The new instrumentation is linked to a computer network, based on real time operating system for data acquisition, display and logging. This paper describes the modules and whole system aspects. (author). 2 refs

  5. Developments in the use of economic instruments in OECD countries

    International Nuclear Information System (INIS)

    Opschoor, H.

    1994-01-01

    For the period 1987-1993, developments in the environmental policies of OECD countries with respect to the use of economic instruments are compared and the differences analyzed. The focus is on applications in the field of air pollution policies. The comparison is made on the basis of two surveys. To complete the descriptive part, a brief survey is also presented of currently discussed and recently introduced economic instruments. A description of economic instruments as such and a review of rationales for employing economic and financial incentives precede this analysis. The analysis shows that the use of economic instruments has indeed increased since 1987, but the development has not been spectacular. Possible explanations for this are presented. Also, some types of instrument have advanced more than others and the changes differ from one set of countries to another. Product charges (including air pollution-related ones) have become more widely used, especially in Scandinavian countries. Moreover, growing attention is being paid to the use of economic instruments at the international level. The incentive impacts of economic (and other) instruments appear to have received relatively little empirical attention, even though these are an important policy-relevant feature in instrument choice. 23 refs., 5 tabs

  6. NASA Instrument Cost Model for Explorer-Like Mission Instruments (NICM-E)

    Science.gov (United States)

    Habib-Agahi, Hamid; Fox, George; Mrozinski, Joe; Ball, Gary

    2013-01-01

    NICM-E is a cost estimating relationship that supplements the traditional NICM System Level CERs for instruments flown on NASA Explorer-like missions that have the following three characteristics: 1) fly on Class C missions, 2) major development led and performed by universities or research foundations, and 3) have significant level of inheritance.

  7. Performance specifications for health physics instrumentation: portable instrumentation for use in normal work environments. Part 2. Test results

    International Nuclear Information System (INIS)

    Kenoyer, J.L.; Swinth, K.L.; Stoetzel, G.A.; Selby, J.M.

    1986-09-01

    The Pacific Northwest Laboratory evaluated a draft American National Standards Institute Standard N42.17 (ANSI N42.17) on performance specifications for health physics instrumentation through a project jointly funded by the US Department of Energy and the US Nuclear Regulatory Commission. The evaluation involved testing a representative cross section of instruments against criteria in the standard. This report presents results of the testing program. A brief history of the project is included in the introduction. The instrumentation tested is described in general terms (i.e., types, ranges); however, no direct relationship between the results and a specific instrument model is made in this report. Testing requirements in ANSI N42.17D4, Revision 1 (May 1985) are summarized and the methods by which the tests are performed are discussed. Brief descriptions of the testing equipment are included in the methods section of the report. More detailed information about the draft standard, testing requirements and procedures, and the test equipment is included in ''Performance Specifications for Health Physics Instrumentation - Portable Instrumentation for Use in Normal Work Environments, Part 1: Manual of Testing Procedures.'' Results of testing are given in two formats: test-by-test and instrument-by-instrument. Discussion is included on significant and interesting findings, on comparisons of results from the same type of instruments from same and different manufacturers, and on data grouped by manufacturer. Conclusions are made on the applicability and practicality of the proposed standard and on instrument performance. Changes that have been made to the proposed standard based on findings of the testing program are listed and discussed. 22 refs., 11 figs., 77 tabs

  8. Active Radiation Level Measurement on New Laboratory Instrument for Evaluating the Antibacterial Activity of Radioisotope

    International Nuclear Information System (INIS)

    Joh, Eunha; Park, Jang Guen

    2014-01-01

    A disc method has been widely used to measure the antibacterial effect of chemical agents. However, it is difficult to measure the antibacterial effect of radioisotopes using a disc method. A disc method is a method for diffusing a drug by placing the drug containing disc on the medium. In this method, radioisotopes are diffused on the medium and it is difficult to measure the exact effect by radiation. Thus, new laboratory equipment needs to evaluate the antibacterial activity by the radioisotopes. In this study, we measured the radiation level of radioisotopes on a new laboratory instrument using a MCNP. A disc method has been widely used to measure the antibacterial effect of chemical agents. This method uses a drug diffusion system for the measurement of anti-bacterial antibiotics. To measure the antimicrobial activity of a radioisotope, a new type of laboratory instrument is necessary to prevent the drug from spreading. The radioisotopes are used to diagnose and treat cancer. However, studies for anti-biotical use have not progressed. The radiation of radioisotopes has the effect of killing bacteria. Before this study proceeds further, it is necessary to be able to measure the antimicrobial activity of the radioisotope easily in the laboratory. However, in this study, it was possible to measure the antimicrobial activity of the radioisotope in the laboratory using a new laboratory instrument. We intend to start evaluation studies of the antibacterial activity of specific radioisotopes. In addition, it will be possible to develop research to overcome diseases caused by bacteria in the future

  9. Active Radiation Level Measurement on New Laboratory Instrument for Evaluating the Antibacterial Activity of Radioisotope

    Energy Technology Data Exchange (ETDEWEB)

    Joh, Eunha; Park, Jang Guen [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    A disc method has been widely used to measure the antibacterial effect of chemical agents. However, it is difficult to measure the antibacterial effect of radioisotopes using a disc method. A disc method is a method for diffusing a drug by placing the drug containing disc on the medium. In this method, radioisotopes are diffused on the medium and it is difficult to measure the exact effect by radiation. Thus, new laboratory equipment needs to evaluate the antibacterial activity by the radioisotopes. In this study, we measured the radiation level of radioisotopes on a new laboratory instrument using a MCNP. A disc method has been widely used to measure the antibacterial effect of chemical agents. This method uses a drug diffusion system for the measurement of anti-bacterial antibiotics. To measure the antimicrobial activity of a radioisotope, a new type of laboratory instrument is necessary to prevent the drug from spreading. The radioisotopes are used to diagnose and treat cancer. However, studies for anti-biotical use have not progressed. The radiation of radioisotopes has the effect of killing bacteria. Before this study proceeds further, it is necessary to be able to measure the antimicrobial activity of the radioisotope easily in the laboratory. However, in this study, it was possible to measure the antimicrobial activity of the radioisotope in the laboratory using a new laboratory instrument. We intend to start evaluation studies of the antibacterial activity of specific radioisotopes. In addition, it will be possible to develop research to overcome diseases caused by bacteria in the future.

  10. Neural correlates of recognition and naming of musical instruments.

    Science.gov (United States)

    Belfi, Amy M; Bruss, Joel; Karlan, Brett; Abel, Taylor J; Tranel, Daniel

    2016-10-01

    Retrieval of lexical (names) and conceptual (semantic) information is frequently impaired in individuals with neurological damage. One category of items that is often affected is musical instruments. However, distinct neuroanatomical correlates underlying lexical and conceptual knowledge for musical instruments have not been identified. We used a neuropsychological approach to explore the neural correlates of knowledge retrieval for musical instruments. A large sample of individuals with focal brain damage (N = 298), viewed pictures of 16 musical instruments and were asked to name and identify each instrument. Neuroanatomical data were analyzed with a proportional MAP-3 method to create voxelwise lesion proportion difference maps. Impaired naming (lexical retrieval) of musical instruments was associated with damage to the left temporal pole and inferior pre- and postcentral gyri. Impaired recognition (conceptual knowledge retrieval) of musical instruments was associated with a more broadly and bilaterally distributed network of regions, including ventromedial prefrontal cortices, occipital cortices, and superior temporal gyrus. The findings extend our understanding of how musical instruments are processed at neural system level, and elucidate factors that may explain why brain damage may or may not produce anomia or agnosia for musical instruments. Our findings also help inform broader understanding of category-related knowledge mapping in the brain, as musical instruments possess several characteristics that are similar to various other categories of items: They are inanimate and highly manipulable (similar to tools), produce characteristic sounds (similar to animals), and require fine-grained visual differentiation between each other (similar to people). (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  11. The effect of vocal and instrumental music on cardio respiratory variables, energy expenditure and exertion levels during sub maximal treadmill exercise.

    Science.gov (United States)

    Savitha, D; Sejil, T V; Rao, Shwetha; Roshan, C J; Roshan, C J

    2013-01-01

    The purpose of the study was to investigate the effect of vocal and instrumental music on various physiological parameters during submaximal exercise. Each subject underwent three sessions of exercise protocol without music, with vocal music, and instrumental versions of same piece of music. The protocol consisted of 10 min treadmill exercise at 70% HR(max) and 20 min of recovery. Minute to minute heart rate and breath by breath recording of respiratory parameters, rate of energy expenditure and perceived exertion levels were measured. Music, irrespective of the presence or absence of lyrics, enabled the subjects to exercise at a significantly lower heart rate and oxygen consumption, reduced the metabolic cost and perceived exertion levels of exercise (P Music having a relaxant effect could have probably increased the parasympathetic activation leading to these effects.

  12. Technological considerations in emergency instrument preparedness

    International Nuclear Information System (INIS)

    Selby, J.M.

    1975-01-01

    The types of emergency instrumentation systems necessary to characterize the severity and extent of radiation accidents and to aid in the protection of operating personnel and personnel living near the plant are discussed. These include instruments for direct measurement of the airborne radioactive material within the facility, fixed instrumentation for ambient dose rate monitoring or area monitoring, and portable instruments for environmental monitoring

  13. Soil monitoring instrumentation

    International Nuclear Information System (INIS)

    Umbarger, C.J.

    1980-01-01

    The Los Alamos Scientific Laboratory (LASL) has an extensive program for the development of nondestructive assay instrumentation for the quantitative analysis of transuranic (TRU) materials found in bulk solid wastes generated by Department of Energy facilities and by the commercial nuclear power industry. Included are wastes generated in decontamination and decommissioning of outdated nuclear facilities as well as wastes from old waste burial ground exhumation programs. The assay instrumentation is designed to have detection limits below 10 nCi/g wherever practicable. Because of the topic of this workshop, only the assay instrumentation applied specifically to soil monitoring will be discussed here. Four types of soil monitors are described

  14. Industrial instrumentation principles and design

    CERN Document Server

    Padmanabhan, Tattamangalam R

    2000-01-01

    Pneumatic, hydraulic and allied instrumentation schemes have given way to electronic schemes in recent years thanks to the rapid strides in electronics and allied areas. Principles, design and applications of such state-of-the-art instrumentation schemes form the subject matter of this book. Through representative examples, the basic building blocks of instrumentation schemes are identified and each of these building blocks discussed in terms of its design and interface characteristics. The common generic schemes synthesized with such building blocks are dealt with subsequently. This forms the scope of Part I. The focus in Part II is on application. Displacement and allied instrumentation, force and allied instrumentation and process instrumentation in terms of temperature, flow, pressure level and other common process variables are dealt with separately and exhaustively. Despite the diversity in the sensor principles and characteristics and the variety in the applications and their environments, it is possib...

  15. Instrument validation project

    International Nuclear Information System (INIS)

    Reynolds, B.A.; Daymo, E.A.; Geeting, J.G.H.; Zhang, J.

    1996-06-01

    Westinghouse Hanford Company Project W-211 is responsible for providing the system capabilities to remove radioactive waste from ten double-shell tanks used to store radioactive wastes on the Hanford Site in Richland, Washington. The project is also responsible for measuring tank waste slurry properties prior to injection into pipeline systems, including the Replacement of Cross-Site Transfer System. This report summarizes studies of the appropriateness of the instrumentation specified for use in Project W-211. The instruments were evaluated in a test loop with simulated slurries that covered the range of properties specified in the functional design criteria. The results of the study indicate that the compact nature of the baseline Project W-211 loop does not result in reduced instrumental accuracy resulting from poor flow profile development. Of the baseline instrumentation, the Micromotion densimeter, the Moore Industries thermocouple, the Fischer and Porter magnetic flow meter, and the Red Valve Pressure transducer meet the desired instrumental accuracy. An alternate magnetic flow meter (Yokagawa) gave nearly identical results as the baseline fischer and Porter. The Micromotion flow meter did not meet the desired instrument accuracy but could potentially be calibrated so that it would meet the criteria. The Nametre on-line viscometer did not meet the desired instrumental accuracy and is not recommended as a quantitative instrument although it does provide qualitative information. The recommended minimum set of instrumentation necessary to ensure the slurry meets the Project W-058 acceptance criteria is the Micromotion mass flow meter and delta pressure cells

  16. Method for including detailed evaluation of daylight levels in Be06

    DEFF Research Database (Denmark)

    Petersen, Steffen

    2008-01-01

    Good daylight conditions in office buildings have become an important issue due to new European regulatory demands which include energy consumption for electrical lighting in the building energy frame. Good daylight conditions in offices are thus in increased focus as an energy conserving measure....... In order to evaluate whether a certain design is good daylight design or not building designers must perform detailed evaluation of daylight levels, including the daylight performance of dynamic solar shadings, and include these in the energy performance evaluation. However, the mandatory national...... calculation tool in Denmark (Be06) for evaluating the energy performance of buildings is currently using a simple representation of available daylight in a room and simple assumptions regarding the control of shading devices. In a case example, this is leading to an overestimation of the energy consumption...

  17. Comparing surgical trays with redundant instruments with trays with reduced instruments: a cost analysis.

    Science.gov (United States)

    John-Baptiste, A; Sowerby, L J; Chin, C J; Martin, J; Rotenberg, B W

    2016-01-01

    When prearranged standard surgical trays contain instruments that are repeatedly unused, the redundancy can result in unnecessary health care costs. Our objective was to estimate potential savings by performing an economic evaluation comparing the cost of surgical trays with redundant instruments with surgical trays with reduced instruments ("reduced trays"). We performed a cost-analysis from the hospital perspective over a 1-year period. Using a mathematical model, we compared the direct costs of trays containing redundant instruments to reduced trays for 5 otolaryngology procedures. We incorporated data from several sources including local hospital data on surgical volume, the number of instruments on redundant and reduced trays, wages of personnel and time required to pack instruments. From the literature, we incorporated instrument depreciation costs and the time required to decontaminate an instrument. We performed 1-way sensitivity analyses on all variables, including surgical volume. Costs were estimated in 2013 Canadian dollars. The cost of redundant trays was $21 806 and the cost of reduced trays was $8803, for a 1-year cost saving of $13 003. In sensitivity analyses, cost savings ranged from $3262 to $21 395, based on the surgical volume at the institution. Variation in surgical volume resulted in a wider range of estimates, with a minimum of $3253 for low-volume to a maximum of $52 012 for high-volume institutions. Our study suggests moderate savings may be achieved by reducing surgical tray redundancy and, if applied to other surgical specialties, may result in savings to Canadian health care systems.

  18. Instrumental analysis of low level of Cs-137 in marine samples by gamma spectrometry; Analise instrumental de baixos niveis de Cs-137 em amostras marinhas por espectrometria gama

    Energy Technology Data Exchange (ETDEWEB)

    Figueira, Rubens C.L.; Silva, Luiz R.N.; Figueiredo, Ana M.G.; Cunha, Ieda I.L. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil). Supervisao de Radioquimica

    1997-12-31

    An instrumental method for low level Cs-137 analysis in marine samples is presented. The method consists in the detector calibration, as well as, determination of detector counting efficiency, accumulative counting of both background and sample and smoothing of 661.6 keV photopeak. The methodology was applied in reference samples and in sediments samples of south Brazilian coast 11 refs., 6 figs., 4 tabs.; e-mail: figueira at net.ipen.br

  19. OECD/CSNI specialist meeting on advanced instrumentation and measurements techniques: summary and conclusions

    International Nuclear Information System (INIS)

    1997-01-01

    This specialist meeting on Advanced Instrumentation and Measurements Techniques was held in Santa Barbara (USA) in 1997 and attracted some 70 participants in ten technical sessions and a session of the round table discussions, with a total of 41 papers. It was intended to bring together the international experts in multi-phase flow instrumentation, experiment and modeling to review the state-of-the-art of the two-phase flow instrumentation methods and to discuss the relation between modeling needs and instrumentation capabilities. The following topics were included: Modeling needs and future direction for improved constitutive relations, interfacial area transport equation, and multi-dimensional two-fluid model formulation; local instrumentation developments for void fraction, interfacial area, phase velocities, turbulence, entrainment, particle size, thermal non-equilibrium, shear stress, nucleation, condensation and boiling; global instrumentation developments for void fraction, mass flow, two-phase level, non-condensable concentration, flow regimes, low flow and break flow; relation between modeling needs and instrumentation capabilities, future directions for experiments focused on modeling needs and for instrumentation developments

  20. Unified instrumentation for determining fissile and radioactive materials

    International Nuclear Information System (INIS)

    Voronov, V.L.; Gorokhov, V.A.; Drozdov, V.Yu.; Morozov, O.S.; Novikov, V.M.

    1999-01-01

    The instrumentation is aimed to equip various facilities: nuclear facilities (including radioactive plant and nuclear material storages), border check stations at the customs, transport junctions, administrative buildings and other facilities. The monitor under design are based on the gamma-spectrometric method of radiation monitoring which consists in recording and analyzing characteristics of X-ray and gamma-sources power spectra within the range of 40-3000 keV at the background level whose value is measured and taken into account during the signal analysis. The designed universal set of instrumentation based on common technical solutions and metrological support plus its small dimensions allows to install it actually in any check point without any significant changes in the room lay-out to facilitate its maintenance [ru

  1. Recommendations for fluorescence instrument qualification: the new ASTM Standard Guide.

    Science.gov (United States)

    DeRose, Paul C; Resch-Genger, Ute

    2010-03-01

    Aimed at improving quality assurance and quantitation for modern fluorescence techniques, ASTM International (ASTM) is about to release a Standard Guide for Fluorescence, reviewed here. The guide's main focus is on steady state fluorometry, for which available standards and instrument characterization procedures are discussed along with their purpose, suitability, and general instructions for use. These include the most relevant instrument properties needing qualification, such as linearity and spectral responsivity of the detection system, spectral irradiance reaching the sample, wavelength accuracy, sensitivity or limit of detection for an analyte, and day-to-day performance verification. With proper consideration of method-inherent requirements and limitations, many of these procedures and standards can be adapted to other fluorescence techniques. In addition, procedures for the determination of other relevant fluorometric quantities including fluorescence quantum yields and fluorescence lifetimes are briefly introduced. The guide is a clear and concise reference geared for users of fluorescence instrumentation at all levels of experience and is intended to aid in the ongoing standardization of fluorescence measurements.

  2. Advanced neutron instrumentation at FRM-II

    International Nuclear Information System (INIS)

    Petry, Winfried

    2003-01-01

    The construction of the new German high flux neutron source FRM-II is finished and FRM-II is waiting for its licence to start nuclear operation. With the beginning of the routine operation 22 instruments will be in action, including 5 irradiation facilities and 17 beam tube instruments, most of them use neutron scattering techniques. Additional instruments are under construction. Some of these instruments are unique, others are expected to be the best of their kind, all instruments are based on innovative techniques. (author)

  3. Instrumentation & Data Acquisition System (D AS) Engineer

    Science.gov (United States)

    Jackson, Markus Deon

    2015-01-01

    The primary job of an Instrumentation and Data Acquisition System (DAS) Engineer is to properly measure physical phenomenon of hardware using appropriate instrumentation and DAS equipment designed to record data during a specified test of the hardware. A DAS system includes a CPU or processor, a data storage device such as a hard drive, a data communication bus such as Universal Serial Bus, software to control the DAS system processes like calibrations, recording of data and processing of data. It also includes signal conditioning amplifiers, and certain sensors for specified measurements. My internship responsibilities have included testing and adjusting Pacific Instruments Model 9355 signal conditioning amplifiers, writing and performing checkout procedures, writing and performing calibration procedures while learning the basics of instrumentation.

  4. Adaptation of WHOQOL as health-related quality of life instrument to develop a vision-specific instrument.

    Directory of Open Access Journals (Sweden)

    Dandona Lalit

    2000-01-01

    Full Text Available The WHOQOL instrument was adapted as a health-related QOL instrument for a population-based epidemiologic study of eye diseases in southern India, the Andhra Pradesh Eye Disease Study (APEDS. A follow-up question was added to each item in WHOQOL to determine whether the decrease in QOL was due to any health reasons including eye-related reasons. Modifications in WHOQOL and translation in local language were done through the use of the focus groups including health professionals and people not related to health care. The modified instrument has 28 items across 6 domains of the WHOQOL and was translated into the local language, Telugu, using the pragmatic approach. It takes 10-20 minutes to be administered by a trained interviewer. Reliability was within acceptable range. This health-related QOL instrument is being used in the population-based study APEDS to develop a vision-specific QOL instrument which could potentially be used to assess the impact of visual impairment on QOL across different cultures and for use in evaluating eye-care interventions. This health-related QOL instrument could also be used to develop other disease-specific instruments as it allows assessment of the extent to which various aspects of QOL are affected by a variety of health problems.

  5. A comparison of instrumentation using Naviflex and Profile nickel-titanium engine-driven rotary instruments.

    Science.gov (United States)

    Ottosen, S R; Nicholls, J I; Steiner, J C

    1999-06-01

    This study was designed to compare the changes in canal configuration resulting from instrumentation by either Profile or Naviflex instruments. Forty mesial canals in extracted human molar teeth were embedded and sectioned at two root levels. Reassembled teeth were instrumented with a modified crown-down technique as described in the Profile training video for Profile files and in a similar manner for Naviflex instruments. Superimposed pre- and postinstrumented cross-sectional root images were projected, traced, and scanned into a computer for analysis. Canal movement, in relation to the furca, and canal area change were recorded. The results showed no significant difference in canal center movement or canal area change between the Profile or Naviflex groups. The degree of canal curvature had no effect on canal center movement or canal area change.

  6. Intelligent type sodium instrumentations for LMFBR

    International Nuclear Information System (INIS)

    Chen Daolong

    1996-07-01

    The constructions and performances of lots of newly developed intelligent type sodium instrumentations are described. The graduation characteristic equations for corresponding transducer using the medium temperature as the parameter are given. These intelligent type sodium instrumentations are possessed of good linearity. The accurate measurement data of sodium process parameters (flowrate, pressure and level) can be obtained by means of their on-line compensation function of the temperature effect. Moreover, these intelligent type sodium instrumentations are possessed of the self-inspection, the electric shutoff protection, the setting of full-scale, the setting of alarm limits (two upper limits and two lower limits alarms), the thermocouple breaking alarm, mutual isolative the 0∼10 V direct-current analogue output and the CENTRONICS standard digital output, and the alarm relay contact output. Theses intelligent type sodium instrumentations are suitable particularly for the instrument, control and protective systems of LMFBR by means of these excellent functions based on microprocessor. The basic errors of the intelligent type sodium flowmeter, immersed sodium flowmeter, sodium manometer and sodium level gauge are +-2%, +-2.3%, +-0.3% and +-1.9% of measuring ranges respectively. (9 figs.)

  7. The interaction between room and musical instruments studied by multi-channel auralization

    DEFF Research Database (Denmark)

    Rindel, Jens Holger; Otondo, Felipe

    2005-01-01

    in the anechoic recording. With this technique the variations in sound radiation from the musical instrument during the performance e.g. due to changes in level or movements can be reproduced with the influence of the surrounding room surfaces. Examples include a grand piano and a clarinet.......The directivity of musical instruments is very complicated and typically changes from one tone to the next. So, instead of measuring the average directivity, a multi-channel auralization method has been developed, which allows a highly accurate and realistic sounding auralization of musical...... instruments in rooms. Anechoic recordings have been made with 5 and 13 evenly distributed microphones around the musical instrument. The reproduction is made with a room acoustics simulation software using a compound source, which is in fact a number of highly directive sources, one for each of the channels...

  8. Instruments to assess stigmatization in dermatology.

    Science.gov (United States)

    Dimitrov, Dimitre; Szepietowski, Jacek C

    2017-11-03

    Stigmatization is the assignment of negative perceptions to an individual because of a perceived difference from the population at large. Skin conditions are frequently the reason of social rejection with a consequent negative influence on the personal and social life of patients. The aim of the current study was to review the available instruments that can be successfully utilized to measure the stigmatization level among dermatological patients. We performed our search on PubMed up to November 2016 and utilized combinations of key phrases containing such words as stigmatization, skin, dermatology, names of various skin conditions (psoriasis, vitiligo, acne, etc.), measurement. The search found a considerable number of articles - 548. After filtering them through a precise selection process, 58 articles remained. We concentrated only on the methodological aspects to assess stigmatization in various dermatoses. The review ascertained that there exist numerous instruments in the form of questionnaires. They were utilized in various researches in order to assess the stigmatization level in patients with skin problems. We divided them into two main groups: dermatology specific instruments (6 questionnaires) and dermatosis/disease specific ones (8 questionnaires). It is recommended to use dermatology-specific instruments to compare the stigmatization level in various skin conditions. They can be utilized as well as a first line tools to study the feeling of stigmatization in specific skin diseases; however, where it is possible, they should be supplemented with the disease-specific instrument for deeper analysis of both qualities of life and stigmatization.

  9. Evaluation of advanced two-phase flow instrumentation in SCTF Core-1

    International Nuclear Information System (INIS)

    Iwamura, Takamichi; Sobajima, Makoto; Osakabe, Masahiro; Ohnuki, Akira; Abe, Yutaka; Sudo, Yukio; Adachi, Hiromichi

    1984-03-01

    In the Slab Core Test Facility (SCTF) Core-I, advanced two-phase flow instruments have been provided by the USNRC to measure the thermohydraulic behavior in the primary system including pressure vessel during the end of blowdown, refill and reflood phases of a postulated loss-of-coolant accident in a pressurized water reactor. The advanced instruments are turbine meters, drag disks, γ-densitometers, spool pieces, liquid level detectors (LLD), fluid distribution grids (FDG), impedance probes (flag, prong and string probes), film probes, and video optical probes. This report presents evaluated results of the data from these instruments. Some instruments are quantitatively evaluated by comparing with the data from the conventional instruments or the other advanced instruments. Main conclusions are as follows: (1) The spool pieces and the γ-densitometers work well and provide satisfactory results; (2) Some of the turbine meters, the impedance probes and the film probes give partially reasonable results, but still more improvements are required; (3) Most of the LLDs, the FDGs, the impedance probes, and the film probes do not work well due to a hard cable corrosion, and (4) The video optical probes give clear image of the flow pattern. (author)

  10. Marketing instruments of foreign trade promotion

    OpenAIRE

    Bjelić Predrag

    2011-01-01

    Instruments of promotion as a part of marketing mix are usually associated with companies but more and more countries use this instrument in order to boost their exports. These foreign trade promotion instruments are now popular in many countries in the world since their use is not opposed to any World Trade Organization rules. Marketing instruments of trade promotions are the most important. They include National Exhibitions and National labels of origin and quality. In order to coordinate t...

  11. Instrument workstation for the EGSE of the Near Infrared Spectro-Photometer instrument (NISP) of the EUCLID mission

    Science.gov (United States)

    Trifoglio, M.; Gianotti, F.; Conforti, V.; Franceschi, E.; Stephen, J. B.; Bulgarelli, A.; Fioretti, V.; Maiorano, E.; Nicastro, L.; Valenziano, L.; Zoli, A.; Auricchio, N.; Balestra, A.; Bonino, D.; Bonoli, C.; Bortoletto, F.; Capobianco, V.; Chiarusi, T.; Corcione, L.; Debei, S.; De Rosa, A.; Dusini, S.; Fornari, F.; Giacomini, F.; Guizzo, G. P.; Ligori, S.; Margiotta, A.; Mauri, N.; Medinaceli, E.; Morgante, G.; Patrizii, L.; Sirignano, C.; Sirri, G.; Sortino, F.; Stanco, L.; Tenti, M.

    2016-07-01

    The NISP instrument on board the Euclid ESA mission will be developed and tested at different levels of integration using various test equipment which shall be designed and procured through a collaborative and coordinated effort. The NISP Instrument Workstation (NI-IWS) will be part of the EGSE configuration that will support the NISP AIV/AIT activities from the NISP Warm Electronics level up to the launch of Euclid. One workstation is required for the NISP EQM/AVM, and a second one for the NISP FM. Each workstation will follow the respective NISP model after delivery to ESA for Payload and Satellite AIV/AIT and launch. At these levels the NI-IWS shall be configured as part of the Payload EGSE, the System EGSE, and the Launch EGSE, respectively. After launch, the NI-IWS will be also re-used in the Euclid Ground Segment in order to support the Commissioning and Performance Verification (CPV) phase, and for troubleshooting purposes during the operational phase. The NI-IWS is mainly aimed at the local storage in a suitable format of the NISP instrument data and metadata, at local retrieval, processing and display of the stored data for on-line instrument assessment, and at the remote retrieval of the stored data for off-line analysis on other computers. We describe the design of the IWS software that will create a suitable interface to the external systems in each of the various configurations envisaged at the different levels, and provide the capabilities required to monitor and verify the instrument functionalities and performance throughout all phases of the NISP lifetime.

  12. Policy instruments to decrease the climate impact of housing, personal transport and food. Detailed instrument descriptions; Ohjauskeinoja asumisen, henkiloeliikenteen ja ruoan ilmastovaikutusten hillintaeaen. Yksityiskohtaiset ohjauskeinokuvaukset

    Energy Technology Data Exchange (ETDEWEB)

    Heiskanen, E.; Perrels, A.; Nissinen, A.; Berghaell, E.; Liesimaa, V.; Mattinen, M. (eds.)

    2012-03-15

    Reducing consumption volumes or introducing climate conscious consumption patterns can be efficient ways to mitigate climate change. Twenty existing policy instruments affecting the greenhouse gas emissions of housing, passenger traffic and food are described in this report of the KUILU-project. The policy instruments and the possibilities to develop effective instrument packages were discussed in two expert workshops, the results of which are presented in annexes of this report. There are already several policy instruments that target on housing and passenger traffic. Their differences in estimated emission reductions are large, which can ease the prioritization and selection of the instruments for further development. So far, only one policy instrument exists that aims to reduce the climate impacts of food choices, namely a Council of State Decision of Principle on Promoting Sustainability in Public Purchasing. However, it includes several measures that can be used to influence private companies and citizens, and thus it opens the field of policy instrument for mitigation of climate impacts of food. According to the expert survey, the most effective policy instrument involved in the analysis was building regulations, and the four most effective instruments after this were the following: gradated procurement tax of cars based on emissions, gradation of car tax, taxation of transport fuels, energy taxes of housing, and the effect of ecodesign directive on appliances. The effectiveness of policy instruments related to food was assessed to be on average level. The five least effective instruments were: EU energy label, voluntary energy experts, the tax of beverage packing, energy certificates, and subsidies for energy efficiency reparation in buildings. However, the expert opinions on the effectiveness of the policy instruments varied significantly. After this report, the KUILU project continued with an analysis of the policy instrument packages and with suggestions

  13. Policy instruments to decrease the climate impact of housing, personal transport and food. Detailed instrument descriptions; Ohjauskeinoja asumisen, henkiloeliikenteen ja ruoan ilmastovaikutusten hillintaeaen. Yksityiskohtaiset ohjauskeinokuvaukset

    Energy Technology Data Exchange (ETDEWEB)

    Heiskanen, E.; Perrels, A.; Nissinen, A.; Berghaell, E.; Liesmaa, V.; Mattinen, M. (eds.)

    2012-07-01

    Reducing consumption volumes or introducing climate conscious consumption patterns can be efficient ways to mitigate climate change. Twenty existing policy instruments affecting the greenhouse gas emissions of housing, passenger traffic and food are described in this report of the KUILU-project. The policy instruments and the possibilities to develop effective instrument packages were discussed in two expert workshops, the results of which are presented in annexes of this report. There are already several policy instruments that target on housing and passenger traffic. Their differences in estimated emission reductions are large, which can ease the prioritization and selection of the instruments for further development. So far, only one policy instrument exists that aims to reduce the climate impacts of food choices, namely a Council of State Decision of Principle on Promoting Sustainability in Public Purchasing. However, it includes several measures that can be used to influence private companies and citizens, and thus it opens the field of policy instrument for mitigation of climate impacts of food. According to the expert survey, the most effective policy instrument involved in the analysis was building regulations, and the four most effective instruments after this were the following: gradated procurement tax of cars based on emissions, gradation of car tax, taxation of transport fuels, energy taxes of housing, and the effect of ecodesign directive on appliances. The effectiveness of policy instruments related to food was assessed to be on average level. The five least effective instruments were: EU energy label, voluntary energy experts, the tax of beverage packing, energy certificates, and subsidies for energy efficiency reparation in buildings. However, the expert opinions on the effectiveness of the policy instruments varied significantly. After this report, the KUILU project continued with an analysis of the policy instrument packages and with suggestions

  14. Natural radioactivity of bedrock bath instruments and hot spring instruments in Japan

    International Nuclear Information System (INIS)

    Kazuki Iwaoka; Hiroyuki Tabe; Hidenori Yonehara

    2013-01-01

    In Japan, bedrock bath instruments and hot spring instruments that contain natural radioactive nuclides are commercially available. In this study, such instruments containing natural radioactive nuclides, currently distributed in Japan, were collected and the radioactivity concentration of 238 U series, 232 Th series, and 40 K in them was determined by gamma ray spectrum analyses. Effective doses to workers and general consumers handling the materials were estimated, revealing the radioactivity concentration of 238 U series, 232 Th series, and 40 K to be lower than critical values given in the IAEA Safety Guide. The maximum effective doses to workers and general consumers were 210 and 6.1 μSv y -1 , respectively. These values are lower than the intervention exemption level (1,000 μSv y -1 ) given in ICRP Publ. 82. (author)

  15. Inexpensive microwave survey instruments: an evaluation

    International Nuclear Information System (INIS)

    Herman, W.A.; Witters, D.M. Jr.

    1979-11-01

    Instruments were tested. Depending upon the oven modulation and leak location these tests show that the Micromate will yield a warning reading at levels from 0.6 to 1.9 mW/cm 2 , when the effects of modulation sensitivity and polarization ellipticity are considered. It is to be expected, then, that this instrument will yield warning readings even when the oven emission being measured lies well within applicable standards. Its apparent susceptibility to overload damage, however, could decrease its sensitivity with no clue to the user as to what had happened. Given the same considerations and parameters, the tests show that the Guard-Rod will yield a warning reading at levels from 3.7 to 47 mW/cm 2 , depending on which measurement surface is used. This instrument will sometimes yield warnings for oven emissions lying within applicable standards, and sometimes will fail to yield such warnings for emissions 10 times greater than allowable levels. The same considerations show that the Interceptor/Microscan units will light up at levels from as low as 0.7 to 0.8 mW/cm 2 or may require levels of 7 to 9 mW/cm 2 . At levels of 28 to 52 mW/cm 2 or higher, however, the warning LED does not light. If part of the field is cross-polarized, this threshold of extinction may be greater. In any case, there is no apparent way for the user to discern the presence of some potentially hazardous fields, and no way to distinguish such fields from a very low-level field. In summary, instruments of the Interceptor/Microscan design may light up at very low power densities, but fail to light at very high power densities. Clearly, this characteristic is extremely undesirable and potentially dangerous to a user relying on such a device.All of these values assume that the instruments are used in accordance with manufacturer's instructions. Otherwise, results may be worse. Moreover, the range of values given take little or no account of unit-to-unit variation, which may be considerable

  16. Instrument care: everyone's responsibility

    Directory of Open Access Journals (Sweden)

    Renée du Toit

    2011-12-01

    Full Text Available Everyone working in an ophthalmic operating theatre must be competent in the care, handling, storage, and maintenance of instruments. This will help to improve surgical outcomes, maintain an economic and affordable service for patients, and provide a safe environment for the wellbeing of patients and staff.Including instrument care in theatre courses and in-service training is one way of ensuring staff competence.

  17. Instrumentation Standard Architectures for Future High Availability Control Systems

    International Nuclear Information System (INIS)

    Larsen, R.S.

    2005-01-01

    Architectures for next-generation modular instrumentation standards should aim to meet a requirement of High Availability, or robustness against system failure. This is particularly important for experiments both large and small mounted on production accelerators and light sources. New standards should be based on architectures that (1) are modular in both hardware and software for ease in repair and upgrade; (2) include inherent redundancy at internal module, module assembly and system levels; (3) include modern high speed serial inter-module communications with robust noise-immune protocols; and (4) include highly intelligent diagnostics and board-management subsystems that can predict impending failure and invoke evasive strategies. The simple design principles lead to fail-soft systems that can be applied to any type of electronics system, from modular instruments to large power supplies to pulsed power modulators to entire accelerator systems. The existing standards in use are briefly reviewed and compared against a new commercial standard which suggests a powerful model for future laboratory standard developments. The past successes of undertaking such projects through inter-laboratory engineering-physics collaborations will be briefly summarized

  18. Detection of random alterations to time-varying musical instrument spectra.

    Science.gov (United States)

    Horner, Andrew; Beauchamp, James; So, Richard

    2004-09-01

    The time-varying spectra of eight musical instrument sounds were randomly altered by a time-invariant process to determine how detection of spectral alteration varies with degree of alteration, instrument, musical experience, and spectral variation. Sounds were resynthesized with centroids equalized to the original sounds, with frequencies harmonically flattened, and with average spectral error levels of 8%, 16%, 24%, 32%, and 48%. Listeners were asked to discriminate the randomly altered sounds from reference sounds resynthesized from the original data. For all eight instruments, discrimination was very good for the 32% and 48% error levels, moderate for the 16% and 24% error levels, and poor for the 8% error levels. When the error levels were 16%, 24%, and 32%, the scores of musically experienced listeners were found to be significantly better than the scores of listeners with no musical experience. Also, in this same error level range, discrimination was significantly affected by the instrument tested. For error levels of 16% and 24%, discrimination scores were significantly, but negatively correlated with measures of spectral incoherence and normalized centroid deviation on unaltered instrument spectra, suggesting that the presence of dynamic spectral variations tends to increase the difficulty of detecting spectral alterations. Correlation between discrimination and a measure of spectral irregularity was comparatively low.

  19. Instrumentation report 1: specification, design, calibration, and installation of instrumentation for an experimental, high-level, nuclear waste storage facility

    International Nuclear Information System (INIS)

    Brough, W.G.; Patrick, W.C.

    1982-01-01

    The Spent Fuel Test-Climax (SFT-C) is being conducted 420 m underground at the Nevada Test Site under the auspices of the US Department of Energy. The test facility houses 11 spent fuel assemblies from an operating commercial nuclear reactor and numerous other thermal sources used to simulate the near-field effects of a large repository. We developed a large-scale instrumentation plan to ensure that a sufficient quality and quantity of data were acquired during the three- to five-year test. These data help satisfy scientific, operational, and radiation safety objectives. Over 800 data channels are being scanned to measure temperature, electrical power, radiation, air flow, dew point, stress, displacement, and equipment operation status (on/off). This document details the criteria, design, specifications, installation, calibration, and current performance of the entire instrumentation package

  20. BIRA-IASB Mars activities and instrument capabilities

    Science.gov (United States)

    Drummond, R.; Vandaele, A.-C.; Gillotay, D.; Willame, Y.; Depiesse, C.; Patel, M.; Daerden, F.; Neefs, E.; Ristic, B.; Montmessin, F.

    2009-04-01

    The Belgian Institute of Space Aeronomy (BIRA-IASB) is involved in many areas of Mars exploration, and has been for a long time. Current activities include analysis of SPICAM data, 3D atmospheric modelling as well as instrument development and characterization. This paper will focus on two different instruments to study the Martian atmosphere. UVIS(Patel, 2006) is part of the Exomars payload, that will gather information on the UV levels on the ground, study climatology and sterilisation and also be able to detect organic material in sublimating permafrost. BIRA-IASB is carrying out the characterization and calibration of UVIS. SOIR is an infra-red spectrometer that uses solar occultation measurements to examine major and minor constituents of planetary atmospheres. SOIR is currently orbiting Venus on the VEX spacecraft and has already made several interesting discoveries including the first observations of a new band of a CO2 isotopologue. The data from SOIR-VEX has allowed us to study the instrumental characteristics and perform a sensitivity study(Mahieux, 2008). These properties have been used to simulate realistic SOIR measurements of Mars atmospheric spectra. This work is supported by extensive 3D chemistry modeling work, as described in a paper by Frank Daerden (PS2.9Atmospheres of terrestrial planets). M. R. Patel, et al.,(2006) The UV-VIS spectrometer for the ExoMars mission, in 36th COSPAR Scientific Assembly, Beijing, China. A. Mahieux, et al.,(2008), Appl. Opt. 47 (13), 2252-65.

  1. The Sensors and Instrumentation Knowledge Transfer Network

    International Nuclear Information System (INIS)

    Cooper, P

    2009-01-01

    The Sensors and Instrumentation KTN has established itself as the UK's national network in sensors and instrumentation, developing a community of over 2,250 member organisations. This paper describes the background to Knowledge Transfer Networks (KTNs) and the changes that are happening to KTNs at a national level, before describing the market size, activities and successes of the Sensors and Instrumentation KTN. The paper concludes by describing the merger between the Sensors and Instrumentation KTN and four other KTNs to create a new KTN, with a working title of the Electronics, Sensors and Photonics KTN.

  2. The 2007 ESO Instrument Calibration Workshop

    CERN Document Server

    Kaufer, Andreas; ESO Workshop

    2008-01-01

    The 2007 ESO Instrument Calibration workshop brought together more than 120 participants with the objective to a) foster the sharing of information, experience and techniques between observers, instrument developers and instrument operation teams, b) review the actual precision and limitations of the applied instrument calibration plans, and c) collect the current and future requirements by the ESO users. These present proceedings include the majority of the workshop’s contributions and document the status quo of instrument calibration at ESO in large detail. Topics covered are: Optical Spectro-Imagers, Optical Multi-Object Spectrographs, NIR and MIR Spectro-Imagers, High-Resolution Spectrographs, Integral Field Spectrographs, Adaptive Optics Instruments, Polarimetric Instruments, Wide Field Imagers, Interferometric Instruments as well as other crucial aspects such as data flow, quality control, data reduction software and atmospheric effects. It was stated in the workshop that "calibration is a life-long l...

  3. Intelligent type sodium instrumentations for LMFR

    International Nuclear Information System (INIS)

    Daolong Chen

    1996-01-01

    The constructions and their performances of a lot of newly developed intelligent type sodium instrumentations that consist of the intelligent type sodium flowmeter, the intelligent type immersed sodium flowmeter, the intelligent type sodium manometer and the intelligent type sodium level gauge are described. The graduation characteristic equations for corresponding transducer using the medium temperature as the parameter are given. Because the operating temperature limit of measured medium (sodium) is wide, so the on-line compensation of the temperature effect of their graduation characteristics much be considered. The tests show that these intelligent type sodium instrumentations possess of good linearity. The accurate sodium process parameter (flowrate, pressure and level) measurement data can be obtained by means of their on-line compensation function of the temperature effect. Moreover, these intelligent type sodium instrumentations possess of the self-inspection, the electric shutoff protection, the setting of full-scale, the setting of alarm limits (two upper limits and two lower limits alarms), the thermocouple breaking alarm, each other isolative the 0-10V direct-current analogue output and CENTRONICS standard digital output, and the alarm relay contact output. These intelligent type sodium instrumentations are suitable particularly for the instrument, control and protective systems of LMFR by means of these excellent functions based on microprocessor. The basic error of the intelligent type sodium flowmeter, immersed sodium flowmeter, sodium manometer and sodium level gauge is respectively ±2%, ±2.3%, ±0.3% and ±1.9% of measuring range. (author). 4 refs, 9 figs

  4. W-026, health physics instrumentation operational test report

    International Nuclear Information System (INIS)

    Hackworth, M.F.

    1998-01-01

    This report documents the testing of the Health Physics Instrumentation associated with phase 2 and 3 start-up of Project W-026, WRAP. The Health Physics Instrumentation includes: Alpha and Beta Continuous Air Monitors (CAMS), Personnel Contamination Monitors (PCMs), Gamma Area Radiation Monitors (ARMs), Criticality Monitors, Alpha and Beta Smear Sample Counters, Portable Friskers, and Operator Breathing Zone Air Samplers. This OTR will cover only the Health Physics Instrumentation that was tested under the Operational test Plan for Health Physics Instrumentation (Phase 2 and 3). That instrumentation included: Alpha CAMS, Beta CAMs and ARMs located in rooms 107 and 113 of 2336-W. The remaining Health Physics Instrumentation that will be used for phase 2 and 3 start-up is tested during calibrations. These calibrations are outside the scope of the Operational Test Plan

  5. Notes on instrumentation and control

    CERN Document Server

    Roy, G J

    2013-01-01

    Notes on Instrumentation and Control presents topics on pressure (i.e., U-tube manometers and elastic type gauges), temperature (i.e. glass thermometer, bi-metallic strip thermometer, filled system thermometer, vapor pressure thermometer), level, and flow measuring devices. The book describes other miscellaneous instruments, signal transmitting devices, supply and control systems, and monitoring systems. The theory of automatic control and semi-conductor devices are also considered. Marine engineers will find the book useful.

  6. Performance of BATAN-SANS instrument

    Energy Technology Data Exchange (ETDEWEB)

    Ikram, Abarrul; Insani, Andon [National Nuclear Energy Agency, P and D Centre for Materials Science and Technology, Serpong (Indonesia)

    2003-03-01

    SANS data from some standard samples have been obtained using BATAN-SANS instrument in Serpong. The experiments were performed for various experimental set-ups that involve different detector positions and collimator lengths. This paper describes the BATAN-SANS instrument briefly as well as the data taken from those experiments and followed with discussion of the results concerning the performance and calibration of the instrument. The standard samples utilized in these experiments include porous silica, polystyrene-poly isoprene, silver behenate, poly ball and polystyrene-poly (ethylene-alt-propylene). Even though the results show that BATAN-SANS instrument is in good shape, but rooms for improvements are still widely open especially for the velocity selector and its control system. (author)

  7. Economic instruments for environmental mitigation

    International Nuclear Information System (INIS)

    Wilkinson, A.

    1995-01-01

    A joint International Chamber of Commerce (ICC)/World Energy Council (WEC) Working Group has been studying a range of policy instruments which are being used or considered for use to address the question of ever increasing energy demand versus environmental protection, and pollution reduction. Economic instruments for such environmental protection include direct regulation, market-based instruments, and voluntary approaches. No single policy or device was likely to suffice in addressing the diversity of environmental problems currently faced. Altering energy prices must be seen in a social context, but some direct regulation may also be inevitable. Generally economic instruments of change were preferred as these were viewed as more flexible and cost-effective. (UK)

  8. The modern trends in space electromagnetic instrumentation

    Science.gov (United States)

    Korepanov, V. E.

    The future trends of the experimental plasma physics development in outer space demand more and more exact and sophisticated scientific instrumentation. Moreover, the situation is complicated by constant reduction of financial support of scientific research, even in leading countries. This resulted in the development of mini; micro and nanosatellites with low price and short preparation time. Consequently, it provoked the creation of new generation of scientific instruments with reduced weight and power consumption but increased level of metrological parameters. The recent state of the development of electromagnetic (EM) sensors for microsatellites is reported. For flux-gate magnetometers (FGM) the reduction of weight as well as power consumption was achieved not only due to the use of new electronic components but also because of the new operation mode development. The scientific and technological study allowed to decrease FGM noise and now the typical noise figure is about 10 picotesla rms at 1 Hz and the record one is below 1 picotesla. The super-light version of search-coil magnetometers (SCM) was created as the result of intensive research. These new SCMs can have about six decades of operational frequency band with upper limit ˜ 1 MHz and noise level of few femtotesla with total weight about 75 grams, including electronics. A new instrument.- wave probe (WP) - which combines three independent sensors in one body - SCM, split Langmuir probe and electric potential sensor - was created. The developed theory confirms that WP can directly measure the wave vector components in space plasmas.

  9. Development and Validation of Nature of Science Instrument for Elementary School Students

    Science.gov (United States)

    Hacieminoglu, Esme; Yilmaz-Tüzün, Özgül; Ertepinar, Hamide

    2014-01-01

    The purposes of this study were to develop and validate an instrument for assessing elementary students' nature of science (NOS) views and to explain the elementary school students' NOS views, in terms of varying grade levels and gender. The sample included 782 students enrolled in sixth, seventh, and eighth grades. Exploratory factor analysis…

  10. Radiochemical and instrumental neutron activation analysis - recent trends

    International Nuclear Information System (INIS)

    Dams, R.

    1990-01-01

    Recent trends of radiochemical and instrumental neutron activation analysis are discussed. Novel developments include the application of cyclic and pulsed activation, better energy resolution with hyperpure germanium detectors, and use of pulse processing systems allowing extremely high count rates of very short-lived isotopes. Further development is anticipated in the field of speciation in biological and environmental studies. Radiochemical methods have led to accurate determinations at the ng/g level. A promising future is expected for neutron activation techniques. (orig.)

  11. Instrumental analysis, second edition

    International Nuclear Information System (INIS)

    Christian, G.D.; O'Reilly, J.E.

    1988-01-01

    The second edition of Instrumental Analysis is a survey of the major instrument-based methods of chemical analysis. It appears to be aimed at undergraduates but would be equally useful in a graduate course. The volume explores all of the classical quantitative methods and contains sections on techniques that usually are not included in a semester course in instrumentation (such as electron spectroscopy and the kinetic methods). Adequate coverage of all of the methods contained in this book would require several semesters of focused study. The 25 chapters were written by different authors, yet the style throughout the book is more uniform than in the earlier edition. With the exception of a two-chapter course in analog and digital circuits, the book purports to de-emphasize instrumentation, focusing more on the theory behind the methods and the application of the methods to analytical problems. However, a detailed analysis of the instruments used in each method is by no means absent. The book has the favor of a user's guide to analysis

  12. Perceived instrumental support and children's health across the early life course.

    Science.gov (United States)

    Turney, Kristin

    2013-10-01

    A large, venerable literature demonstrates the importance of social relationships and social support for health, though much less research examines whether the benefits of social support to mothers extend to children. This paper examines the relationship between mothers' perceptions of instrumental support and children's health using longitudinal data from the U.S. Fragile Families and Child Wellbeing Study (N = 4342), a cohort of American children born in urban areas to mostly unmarried parents. Results suggest mothers' perceptions of instrumental support is positively associated with children's overall health, and this finding persists despite controlling for a host of individual-level characteristics of mothers and children (including a lagged indicator of children's health) and in fixed-effect models. Mothers' economic security and mothers' wellbeing attenuate some, but not all, of the association between perceived instrumental support and children's overall health. In addition, the link between perceived instrumental support and three specific indicators of health - asthma, overweight/obese, and number of emergency room visits - falls to statistical insignificance after accounting for individual-level characteristics, suggesting these associations result from social selection processes. Taken together, these findings suggest the beneficial health consequences of social support may extend to children across the early life course and demonstrate the need to better understand mothers' reports of children's overall health. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. Instrumentation requirements for the ESF thermomechanical experiments

    International Nuclear Information System (INIS)

    Pott, J.; Brechtel, C.E.

    1992-01-01

    In situ thermomechanical experiments are planned as part of the Yucca Mountain Site Characterization Project that require instruments to measure stress and displacement at temperatures that exceed the typical specifications of existing geotechnical instruments. A high degree of instrument reliability will also be required to satisfy the objectives of the experiments, therefore a study was undertaken to identify areas where improvement in instrument performance was required. A preliminary list of instruments required for the experiments was developed, based on existing test planning and analysis. Projected temperature requirements were compared to specifications of existing instruments to identify instrumentation development needs. Different instrument technologies, not currently employed in geotechnical instrumentation, were reviewed to identify potential improvements of existing designs for the high temperature environment. Technologies with strong potentials to improve instrument performance with relatively high reliability include graphite fiber composite materials, fiber optics, and video imagery

  14. Proceedings of the 38th international instrumentation symposium

    International Nuclear Information System (INIS)

    Richter, S.H.; Smith, E.A.

    1991-01-01

    This volume covers the proceedings of a symposium on instrumentation within the Aerospace and Test Measurement Divisions of the Instrument Society of America. Topics covered included: PC control in turbine engine testing, energy measurement of high proton beams, instrumentation for sampling related to the US clean Air Act, and instrumentation for monitoring in-reactor severe fuel damage tests

  15. Fabrication of internally instrumented reactor fuel rods

    International Nuclear Information System (INIS)

    Schmutz, J.D.; Meservey, R.H.

    1975-01-01

    Procedures are outlined for fabricating internally instrumented reactor fuel rods while maintaining the original quality assurance level of the rods. Instrumented fuel rods described contain fuel centerline thermocouples, ultrasonic thermometers, and pressure tubes for internal rod gas pressure measurements. Descriptions of the thermocouples and ultrasonic thermometers are also contained

  16. A systematic review of instruments to assess organizational readiness for knowledge translation in health care.

    Directory of Open Access Journals (Sweden)

    Marie-Pierre Gagnon

    Full Text Available The translation of research into practices has been incomplete. Organizational readiness for change (ORC is a potential facilitator of effective knowledge translation (KT. However we know little about the best way to assess ORC. Therefore, we sought to systematically review ORC measurement instruments.We searched for published studies in bibliographic databases (Pubmed, Embase, CINAHL, PsychINFO, Web of Science, etc. up to November 1st, 2012. We included publications that developed ORC measures and/or empirically assessed ORC using an instrument at the organizational level in the health care context. We excluded articles if they did not refer specifically to ORC, did not concern the health care domain or were limited to individual-level change readiness. We focused on identifying the psychometric properties of instruments that were developed to assess readiness in an organization prior to implementing KT interventions in health care. We used the Standards for Educational and Psychological Testing to assess the psychometric properties of identified ORC measurement instruments.We found 26 eligible instruments described in 39 publications. According to the Standards for Educational and Psychological Testing, 18 (69% of a total of 26 measurement instruments presented both validity and reliability criteria. The Texas Christian University -ORC (TCU-ORC scale reported the highest instrument validity with a score of 4 out of 4. Only one instrument, namely the Modified Texas Christian University - Director version (TCU-ORC-D, reported a reliability score of 2 out of 3. No information was provided regarding the reliability and validity of five (19% instruments.Our findings indicate that there are few valid and reliable ORC measurement instruments that could be applied to KT in the health care sector. The TCU-ORC instrument presents the best evidence in terms of validity testing. Future studies using this instrument could provide more knowledge on its

  17. Instrumentation and control strategies for an integral pressurized water reactor

    Directory of Open Access Journals (Sweden)

    Belle R. Upadhyaya

    2015-03-01

    Full Text Available Several vendors have recently been actively pursuing the development of integral pressurized water reactors (iPWRs that range in power levels from small to large reactors. Integral reactors have the features of minimum vessel penetrations, passive heat removal after reactor shutdown, and modular construction that allow fast plant integration and a secure fuel cycle. The features of an integral reactor limit the options for placing control and safety system instruments. The development of instrumentation and control (I&C strategies for a large 1,000 MWe iPWR is described. Reactor system modeling—which includes reactor core dynamics, primary heat exchanger, and the steam flashing drum—is an important part of I&C development and validation, and thereby consolidates the overall implementation for a large iPWR. The results of simulation models, control development, and instrumentation features illustrate the systematic approach that is applicable to integral light water reactors.

  18. Report of the Instrumentation Service - Annex C

    International Nuclear Information System (INIS)

    Majstorovic, D.

    1987-01-01

    This report describes the tasks and organizational structure of the Instrumentation service. The most important task of this Service is control and maintenance of the reactor control and protection instruments, operation control, and dosimetry system. Besides data about this basic instrumentation, the report includes data about control and maintenance of other electronic equipment related to experimental facilities [sr

  19. ICFA: Instrumentation school

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1987-10-15

    74 students, including 45 from developing countries, ten lecturers and nine laboratory instructors participated in the novel instrumentation school held in June at the International Centre for Theoretical Physics (ICTP), Trieste, Italy, sponsored by ICTP and arranged through the Instrumentation Panel of the International Committee for Future Accelerators (ICF). During the two weeks of the course, students had the chance to construct and test a proportional chamber, measure the lifetime of cosmic ray muons, operate and analyse the performance of an 8-wire imaging drift chamber, or study noise and signal processing using a silicon photodiode.

  20. ICFA: Instrumentation school

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    74 students, including 45 from developing countries, ten lecturers and nine laboratory instructors participated in the novel instrumentation school held in June at the International Centre for Theoretical Physics (ICTP), Trieste, Italy, sponsored by ICTP and arranged through the Instrumentation Panel of the International Committee for Future Accelerators (ICF). During the two weeks of the course, students had the chance to construct and test a proportional chamber, measure the lifetime of cosmic ray muons, operate and analyse the performance of an 8-wire imaging drift chamber, or study noise and signal processing using a silicon photodiode

  1. A new instrument of VUV laser desorption/ionization mass spectrometry imaging with micrometer spatial resolution and low level of molecular fragmentation.

    Science.gov (United States)

    Wang, Jia; Liu, Feng; Mo, Yuxiang; Wang, Zhaoying; Zhang, Sichun; Zhang, Xinrong

    2017-11-01

    Mass spectrometry imaging (MSI) has important applications in material research, biology, and medicine. The MSI method based on UV laser desorption/ionization (UVLDI) can obtain images of intact samples, but has a high level of molecular fragmentation. In this work, we report a new MSI instrument that uses a VUV laser (125.3 nm) as a desorption/ionization source to exploit its advantages of high single photon energy and small focus size. The new instrument was tested by the mass spectra of Nile red and FGB (Fibrinogen beta chain) samples and mass spectrometric images of a fly brain section. For the tested samples, the VUVDI method offers lower levels of molecular fragmentations and higher sensitivities than those of the UVLDI method and second ion mass spectrometry imaging method using a Bi 3 + beam. The ablation crater produced by the focused VUV laser on a quartz plate has an area of 10 μm 2 . The VUV laser is prepared based on the four-wave mixing method using three collimated laser beams and a heated Hg cell.

  2. A new instrument of VUV laser desorption/ionization mass spectrometry imaging with micrometer spatial resolution and low level of molecular fragmentation

    Science.gov (United States)

    Wang, Jia; Liu, Feng; Mo, Yuxiang; Wang, Zhaoying; Zhang, Sichun; Zhang, Xinrong

    2017-11-01

    Mass spectrometry imaging (MSI) has important applications in material research, biology, and medicine. The MSI method based on UV laser desorption/ionization (UVLDI) can obtain images of intact samples, but has a high level of molecular fragmentation. In this work, we report a new MSI instrument that uses a VUV laser (125.3 nm) as a desorption/ionization source to exploit its advantages of high single photon energy and small focus size. The new instrument was tested by the mass spectra of Nile red and FGB (Fibrinogen beta chain) samples and mass spectrometric images of a fly brain section. For the tested samples, the VUVDI method offers lower levels of molecular fragmentations and higher sensitivities than those of the UVLDI method and second ion mass spectrometry imaging method using a Bi3+ beam. The ablation crater produced by the focused VUV laser on a quartz plate has an area of 10 μm2. The VUV laser is prepared based on the four-wave mixing method using three collimated laser beams and a heated Hg cell.

  3. Some emergency instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Burgess, P H

    1986-10-01

    The widespread release of activity and the resultant spread of contamination after the Chernobyl accident resulted in requests to NRPB to provide instruments for, and expertise in, the measurement of radiation. The most common request was for advice on the usefulness of existing instruments, but Board staff were also involved in their adaptation or in the development of new instruments specially to meet the circumstances of the accident. The accident occurred on 26 April. On 1 May, NRPB was involved at Heathrow Airport in the monitoring of the British students who had returned from Kiev and Minsk. The main purpose was to reassure the students by checking that their persons and belongings did not have significant surface contamination. Additional measurements were also made of iodine activity in thyroid using hand-held detectors or a mobile body monitor. This operation was arranged with the Foreign and Commonwealth Office, which had also received numerous requests for instruments from embassies and consulates in countries close to the scene of the accident. There was concern for the well-being of staff and other United Kingdom nationals who resided in or intended to visit the most affected countries. The board supplied suitable instruments, and the FCO distributed them to embassies. The frequency of environmental monitoring was increased from 29 April in anticipation of contamination and appropriate Board instrumentation was deployed. After the Chernobyl cloud arrived in the UK on 2 May, there were numerous requests from local government, public authorities, private companies and members of the public for information and advice on monitoring equipment and procedures. Some of these requirements could be met with existing equipment but members of the public were usually advised not to proceed. At a later stage, the contamination of foodstuffs and livestock required the development of an instrument capable of detecting low levels of {sup 137}Cs and {sup 134}Cs in food

  4. Energy-efficiency instruments in the electricity area

    International Nuclear Information System (INIS)

    Hammer, S.; Oettli, B.; Schneider, Ch.; Iten, R.; Peherstorfer, N.

    2007-06-01

    This comprehensive report for the Swiss Federal Office of Energy (SFOE) describes a mix of instruments that could increase the efficiency of electricity usage in Switzerland. The basis for the development of these instruments - the experience gained in Europe in this area - is discussed. Explicitly not discussed are energy and electricity steering taxes, which could also be part of a future instrument-mix. The measures suggested include the setting of compulsory long-term reduction targets that are to form the basis for strategies and measures to be taken in particular areas and the development of an appropriate instrument-mix for this purpose. These could include regulations and labels, a national fund and certificate trading. Suppliers of electricity could be committed to increasing the efficiency of electricity use and national programmes could also attempt to influence consumer habits. The instruments should, according to the authors, be based on the existing legal framework and use know-how and structures that are already available

  5. 18 CFR 367.1750 - Account 175, Derivative instrument assets.

    Science.gov (United States)

    2010-04-01

    ... the corresponding amount of the change in the fair value of the derivative instrument. ... instrument assets. This account must include the amounts paid for derivative instruments, and the change in the fair value of all derivative instrument assets not designated as cash flow or fair value hedges...

  6. Health-related quality of life and hand eczema--a comparison of two instruments, including factor analysis.

    Science.gov (United States)

    Wallenhammar, Lena-Marie; Nyfjäll, Mats; Lindberg, Magnus; Meding, Birgitta

    2004-06-01

    Hand eczema is a disease of long duration, affecting the individual and society. The purpose of this study of 100 patients (51 females and 49 males) at an occupational dermatology clinic was to investigate whether the generic questionnaire Short Form-36 (SF-36), and the dermatology-specific Dermatology Life Quality Index (DLQI) are appropriate for assessing health-related quality of life (HRQL) in patients with hand eczema, and whether gender differences in HRQL could be detected. HRQL was affected by hand eczema, measured with both SF-36 and DLQI. The SF-36 showed more impaired HRQL for females than for males, in the mental health dimension, whereas no gender-related differences were detected with the DLQI. To compare the instruments we used factor analysis, with a polychoric correlation matrix as input, thus taking the ordinal aspect of the data into account. There was a high correlation between the instruments for physical health, but lower for mental health. In this context our interpretation of the factor analysis is that the SF-36 measures mental health better than the DLQI. The SF-36 therefore appears suitable for use in future studies for measuring HRQL, and gender differences in HRQL, in persons with reported hand eczema.

  7. Recognition of Instrumentation Gauge in the Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jai Wan; Jeong, Kyung Min [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    Nuclear emergency robots were developed in 2001 as the countermeasure following the criticality accident at the JCO (uranium refinery facility) in Tokaimura, Japan in 1999. We assumed that these nuclear emergency robots were deployed (or put into) for a mitigation (or management) of severe accident, for example, occurred at Fukushima Daiichi nuclear power plant. In the case, the image understanding using a color CCD camera, loaded on the nuclear emergency robot, is important. We proposed an image processing technique to read indication value of the IC water level gauges using the structural characteristics of the instrumentation panels (water level gauges) located inside the reactor building. At first, we recognized the scales on the instrumentation panel using the geometric shape of the panel. And then, we could read the values of the instrumentation gauge by calculating the slope of the needle on the gauge. Using the proposed algorithm, we deciphered instrumentation panels for the four water level gauges and indicators shown on the IC video released by TEPCO and Japanese Nuclear Regulatory Commission of Japan. In this paper, recognition of the instrumentation gauges inside reactor building of the nuclear power plant by an image processing technology is described.

  8. Evaluation of apical canal shapes produced sequentially during instrumentation with stainless steel hand and Ni-Ti rotary instruments using Micro-computed tomography

    Directory of Open Access Journals (Sweden)

    Woo-Jin Lee

    2011-05-01

    Full Text Available Objectives The purpose of this study was to determine the optimal master apical file size with minimal transportation and optimal efficiency in removing infected dentin. We evaluated the transportation of the canal center and the change in untouched areas after sequential preparation with a #25 to #40 file using 3 different instruments: stainless steel K-type (SS K-file hand file, ProFile and LightSpeed using microcomputed tomography (MCT. Materials and Methods Thirty extracted human mandibular molars with separated orifices and apical foramens on mesial canals were used. Teeth were randomly divided into three groups: SS K-file, Profile, LightSpeed and the root canals were instrumented using corresponding instruments from #20 to #40. All teeth were scanned with MCT before and after instrumentation. Cross section images were used to evaluate canal transportation and untouched area at 1- , 2- , 3- , and 5- mm level from the apex. Data were statistically analyzed according to' repeated nested design'and Mann-Whitney test (p = 0.05. Results In SS K-file group, canal transportation was significantly increased over #30 instrument. In the ProFile group, canal transportation was significantly increased after preparation with the #40 instrument at the 1- and 2- mm levels. LightSpeed group showed better centering ability than ProFile group after preparation with the #40 instrument at the 1 and 2 mm levels. Conclusions SS K-file, Profile, and LightSpeed showed differences in the degree of apical transportation depending on the size of the master apical file.

  9. Social Responsibility Instruments

    Directory of Open Access Journals (Sweden)

    Katarzyna Mizera

    2008-09-01

    Full Text Available Responsible business notion is more and more present in Polish economy, however the results of the research carried out in Polish business still shows a low level of CRS idea knowledge, especially in small and medium companies. Although responsible business notion is generally known, its details, ways of preparing strategy, instruments and what is more its benefits are still narrowly spread. Many business people face the lack of knowledge and information, which on one hand make it easier to spread and deepen wrong stereotypes connected with this notion and on the other hand make business people unwilling to implement CRS in their companies. The subjects of this article are examples of instruments which are responsible for realization of social responsibility strategy.

  10. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. An inspector-instrument interface design that allows communication of procedures, responses, and results between the instrument and user is presented. This capability has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  11. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. This report describes an inspector-instrument interface design which allows communication of procedures, responses, and results between the instrument and user. The interface has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  12. Intelligent instrumentation principles and applications

    CERN Document Server

    Bhuyan, Manabendra

    2011-01-01

    With the advent of microprocessors and digital-processing technologies as catalyst, classical sensors capable of simple signal conditioning operations have evolved rapidly to take on higher and more specialized functions including validation, compensation, and classification. This new category of sensor expands the scope of incorporating intelligence into instrumentation systems, yet with such rapid changes, there has developed no universal standard for design, definition, or requirement with which to unify intelligent instrumentation. Explaining the underlying design methodologies of intelligent instrumentation, Intelligent Instrumentation: Principles and Applications provides a comprehensive and authoritative resource on the scientific foundations from which to coordinate and advance the field. Employing a textbook-like language, this book translates methodologies to more than 80 numerical examples, and provides applications in 14 case studies for a complete and working understanding of the material. Beginn...

  13. Technological considerations in emergency instrument preparedness

    International Nuclear Information System (INIS)

    Selby, J.M.

    1976-01-01

    Emergency preparedness has been emphasized during the development of the nuclear industry. Existing instrumentation technology has been effectively applied to minimizing the probability of accidents. Radiological instrumentation provided for the measurement of ambient radiation levels or routine releases of radioactive material is usually adequate to provide an early warning that an accident is occurring. In contrast, radiological instrumentation capable of providing a reasonable measure of the source term which could be involved in a severe accident has not received enough attention. In emergency planning the capability should be established for identifying as promptly as possible the need for evasive action out in the plant environs and for minimizing the consequences of an accident in terms of resultant human exposure. Therefore instrumentation is required to measure the source term no matter where the point of release might be, together with instrumentation for obtaining meteorological data sufficient to establish the path of the release in the environment

  14. Minimally invasive instrumentation without fusion during posterior thoracic corpectomies: a comparison of percutaneously instrumented nonfused segments with open instrumented fused segments.

    Science.gov (United States)

    Lau, Darryl; Chou, Dean

    2017-07-01

    OBJECTIVE During the mini-open posterior corpectomy, percutaneous instrumentation without fusion is performed above and below the corpectomy level. In this study, the authors' goal was to compare the perioperative and long-term implant failure rates of patients who underwent nonfused percutaneous instrumentation with those of patients who underwent traditional open instrumented fusion. METHODS Adult patients who underwent posterior thoracic corpectomies with cage reconstruction between 2009 and 2014 were identified. Patients who underwent mini-open corpectomy had percutaneous instrumentation without fusion, and patients who underwent open corpectomy had instrumented fusion above and below the corpectomy site. The authors compared perioperative outcomes and rates of implant failure requiring reoperation between the open (fused) and mini-open (unfused) groups. RESULTS A total of 75 patients were identified, and 53 patients (32 open and 21 mini-open) were available for followup. The mean patient age was 52.8 years, and 56.6% of patients were male. There were no significant differences in baseline variables between the 2 groups. The overall perioperative complication rate was 15.1%, and there was no significant difference between the open and mini-open groups (18.8% vs 9.5%; p = 0.359). The mean hospital stay was 10.5 days. The open group required a significantly longer stay than the mini-open group (12.8 vs 7.1 days; p open and mini-open groups at 6 months (3.1% vs 0.0%, p = 0.413), 1 year (10.7% vs 6.2%, p = 0.620), and 2 years (18.2% vs 8.3%, p = 0.438). The overall mean follow-up was 29.2 months. CONCLUSIONS These findings suggest that percutaneous instrumentation without fusion in mini-open transpedicular corpectomies offers similar implant failure and reoperation rates as open instrumented fusion as far out as 2 years of follow-up.

  15. Compendium of Instrumentation Whitepapers on Frontier Physics Needs for Snowmass 2013

    Energy Technology Data Exchange (ETDEWEB)

    Lipton, R. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2013-01-01

    Contents of collection of whitepapers include: Operation of Collider Experiments at High Luminosity; Level 1 Track Triggers at HL-LHC; Tracking and Vertex Detectors for a Muon Collider; Triggers for hadron colliders at the energy frontier; ATLAS Upgrade Instrumentation; Instrumentation for the Energy Frontier; Particle Flow Calorimetry for CMS; Noble Liquid Calorimeters; Hadronic dual-readout calorimetry for high energy colliders; Another Detector for the International Linear Collider; e+e- Linear Colliders Detector Requirements and Limitations; Electromagnetic Calorimetry in Project X Experiments The Project X Physics Study; Intensity Frontier Instrumentation; Project X Physics Study Calorimetry Report; Project X Physics Study Tracking Report; The LHCb Upgrade; Neutrino Detectors Working Group Summary; Advanced Water Cherenkov R&D for WATCHMAN; Liquid Argon Time Projection Chamber (LArTPC); Liquid Scintillator Instrumentation for Physics Frontiers; A readout architecture for 100,000 pixel Microwave Kinetic In- ductance Detector array; Instrumentation for New Measurements of the Cosmic Microwave Background polarization; Future Atmospheric and Water Cherenkov ?-ray Detectors; Dark Energy; Can Columnar Recombination Provide Directional Sensitivity in WIMP Search?; Instrumentation Needs for Detection of Ultra-high Energy Neu- trinos; Low Background Materials for Direct Detection of Dark Matter; Physics Motivation for WIMP Dark Matter Directional Detection; Solid Xenon R&D at Fermilab; Ultra High Energy Neutrinos; Instrumentation Frontier: Direct Detection of WIMPs; nEXO detector R&D; Large Arrays of Air Cherenkov Detectors; and Applications of Laser Interferometry in Fundamental Physics Experiments.

  16. Post endodontic pain following single-visit root canal preparation with rotary vs reciprocating instruments: a meta-analysis of randomized clinical trials.

    Science.gov (United States)

    Hou, Xiao-Mei; Su, Zheng; Hou, Ben-Xiang

    2017-05-25

    In endodontic therapy, continuous rotary instrumentation reduced debris compared to reciprocal instrumentation, which might affect the incidence of post-endodontic pain (PP). The aim of our study was to assess whether PP incidence and levels were influenced by the choice of rotary or reciprocal instruments. In this meta-analysis the Pubmed and EM databases were searched for prospective clinical randomized trials published before April 20, 2016, using combinations of the keywords: root canal preparation/instrumentation/treatment/therapy; post-operative/endodontic pain; reciprocal and rotary instruments. Three studies were included, involving a total of 1,317 patients, 659 treated with reciprocating instruments and 658 treated with rotary instruments. PP was reported in 139 patients in the reciprocating group and 172 in the rotary group. The PP incidence odds ratio was 1.27 with 95% confidence interval (CI) (0.25, 6.52) favoring rotary instruments. The mild, moderate and severe PP levels odds ratios were 0.31 (0.11, 0.84), 2.24 (0.66, 7.59) and 11.71 (0.63, 218.15), respectively. No evidence of publication bias was found. Rotary instrument choice in endodontic therapy is associated with a lower incidence of PP than reciprocating instruments, while reciprocating instruments are associated with less mild PP incidence.

  17. Assessing hospitals' clinical risk management: Development of a monitoring instrument

    Directory of Open Access Journals (Sweden)

    Pfeiffer Yvonne

    2010-12-01

    Full Text Available Abstract Background Clinical risk management (CRM plays a crucial role in enabling hospitals to identify, contain, and manage risks related to patient safety. So far, no instruments are available to measure and monitor the level of implementation of CRM. Therefore, our objective was to develop an instrument for assessing CRM in hospitals. Methods The instrument was developed based on a literature review, which identified key elements of CRM. These elements were then discussed with a panel of patient safety experts. A theoretical model was used to describe the level to which CRM elements have been implemented within the organization. Interviews with CRM practitioners and a pilot evaluation were conducted to revise the instrument. The first nationwide application of the instrument (138 participating Swiss hospitals was complemented by in-depth interviews with 25 CRM practitioners in selected hospitals, for validation purposes. Results The monitoring instrument consists of 28 main questions organized in three sections: 1 Implementation and organizational integration of CRM, 2 Strategic objectives and operational implementation of CRM at hospital level, and 3 Overview of CRM in different services. The instrument is available in four languages (English, German, French, and Italian. It allows hospitals to gather comprehensive and systematic data on their CRM practice and to identify areas for further improvement. Conclusions We have developed an instrument for assessing development stages of CRM in hospitals that should be feasible for a continuous monitoring of developments in this important area of patient safety.

  18. Assessing hospitals' clinical risk management: Development of a monitoring instrument.

    Science.gov (United States)

    Briner, Matthias; Kessler, Oliver; Pfeiffer, Yvonne; Wehner, Theo; Manser, Tanja

    2010-12-13

    Clinical risk management (CRM) plays a crucial role in enabling hospitals to identify, contain, and manage risks related to patient safety. So far, no instruments are available to measure and monitor the level of implementation of CRM. Therefore, our objective was to develop an instrument for assessing CRM in hospitals. The instrument was developed based on a literature review, which identified key elements of CRM. These elements were then discussed with a panel of patient safety experts. A theoretical model was used to describe the level to which CRM elements have been implemented within the organization. Interviews with CRM practitioners and a pilot evaluation were conducted to revise the instrument. The first nationwide application of the instrument (138 participating Swiss hospitals) was complemented by in-depth interviews with 25 CRM practitioners in selected hospitals, for validation purposes. The monitoring instrument consists of 28 main questions organized in three sections: 1) Implementation and organizational integration of CRM, 2) Strategic objectives and operational implementation of CRM at hospital level, and 3) Overview of CRM in different services. The instrument is available in four languages (English, German, French, and Italian). It allows hospitals to gather comprehensive and systematic data on their CRM practice and to identify areas for further improvement. We have developed an instrument for assessing development stages of CRM in hospitals that should be feasible for a continuous monitoring of developments in this important area of patient safety.

  19. Instrumentational complexity of music genres and why simplicity sells.

    Directory of Open Access Journals (Sweden)

    Gamaliel Percino

    Full Text Available Listening habits are strongly influenced by two opposing aspects, the desire for variety and the demand for uniformity in music. In this work we quantify these two notions in terms of instrumentation and production technologies that are typically involved in crafting popular music. We assign an 'instrumentational complexity value' to each music style. Styles of low instrumentational complexity tend to have generic instrumentations that can also be found in many other styles. Styles of high complexity, on the other hand, are characterized by a large variety of instruments that can only be found in a small number of other styles. To model these results we propose a simple stochastic model that explicitly takes the capabilities of artists into account. We find empirical evidence that individual styles show dramatic changes in their instrumentational complexity over the last fifty years. 'New wave' or 'disco' quickly climbed towards higher complexity in the 70s and fell back to low complexity levels shortly afterwards, whereas styles like 'folk rock' remained at constant high instrumentational complexity levels. We show that changes in the instrumentational complexity of a style are related to its number of sales and to the number of artists contributing to that style. As a style attracts a growing number of artists, its instrumentational variety usually increases. At the same time the instrumentational uniformity of a style decreases, i.e. a unique stylistic and increasingly complex expression pattern emerges. In contrast, album sales of a given style typically increase with decreasing instrumentational complexity. This can be interpreted as music becoming increasingly formulaic in terms of instrumentation once commercial or mainstream success sets in.

  20. Instrumentational Complexity of Music Genres and Why Simplicity Sells

    Science.gov (United States)

    Percino, Gamaliel; Klimek, Peter; Thurner, Stefan

    2014-01-01

    Listening habits are strongly influenced by two opposing aspects, the desire for variety and the demand for uniformity in music. In this work we quantify these two notions in terms of instrumentation and production technologies that are typically involved in crafting popular music. We assign an ‘instrumentational complexity value’ to each music style. Styles of low instrumentational complexity tend to have generic instrumentations that can also be found in many other styles. Styles of high complexity, on the other hand, are characterized by a large variety of instruments that can only be found in a small number of other styles. To model these results we propose a simple stochastic model that explicitly takes the capabilities of artists into account. We find empirical evidence that individual styles show dramatic changes in their instrumentational complexity over the last fifty years. ‘New wave’ or ‘disco’ quickly climbed towards higher complexity in the 70s and fell back to low complexity levels shortly afterwards, whereas styles like ‘folk rock’ remained at constant high instrumentational complexity levels. We show that changes in the instrumentational complexity of a style are related to its number of sales and to the number of artists contributing to that style. As a style attracts a growing number of artists, its instrumentational variety usually increases. At the same time the instrumentational uniformity of a style decreases, i.e. a unique stylistic and increasingly complex expression pattern emerges. In contrast, album sales of a given style typically increase with decreasing instrumentational complexity. This can be interpreted as music becoming increasingly formulaic in terms of instrumentation once commercial or mainstream success sets in. PMID:25551631

  1. Instrumentational complexity of music genres and why simplicity sells.

    Science.gov (United States)

    Percino, Gamaliel; Klimek, Peter; Thurner, Stefan

    2014-01-01

    Listening habits are strongly influenced by two opposing aspects, the desire for variety and the demand for uniformity in music. In this work we quantify these two notions in terms of instrumentation and production technologies that are typically involved in crafting popular music. We assign an 'instrumentational complexity value' to each music style. Styles of low instrumentational complexity tend to have generic instrumentations that can also be found in many other styles. Styles of high complexity, on the other hand, are characterized by a large variety of instruments that can only be found in a small number of other styles. To model these results we propose a simple stochastic model that explicitly takes the capabilities of artists into account. We find empirical evidence that individual styles show dramatic changes in their instrumentational complexity over the last fifty years. 'New wave' or 'disco' quickly climbed towards higher complexity in the 70s and fell back to low complexity levels shortly afterwards, whereas styles like 'folk rock' remained at constant high instrumentational complexity levels. We show that changes in the instrumentational complexity of a style are related to its number of sales and to the number of artists contributing to that style. As a style attracts a growing number of artists, its instrumentational variety usually increases. At the same time the instrumentational uniformity of a style decreases, i.e. a unique stylistic and increasingly complex expression pattern emerges. In contrast, album sales of a given style typically increase with decreasing instrumentational complexity. This can be interpreted as music becoming increasingly formulaic in terms of instrumentation once commercial or mainstream success sets in.

  2. Math Garden: A new educational and scientific instrument

    NARCIS (Netherlands)

    Straatemeier, M.

    2014-01-01

    This dissertation describes the research concerning the construction of a new educational and scientific instrument. This instrument, Math Garden, is a web application in which children can practice arithmetic by playing math games in which items are tailored to their ability level. At the same

  3. Tamper indicating radiation surveillance instrumentation

    International Nuclear Information System (INIS)

    Chambers, W.H.; Ney, J.F.

    1975-01-01

    Prototype personnel and shipping dock portal monitors suitable for unattended use were fabricated and tested. The requirement for continuous operation with only periodic inspection along with a desire for minimum costs and minimum interference with normal plant operation imposed unique design constraints. The design, operation, and performance of the detection and data recording instrumentation are described, as well as the tamper indicating techniques required to protect the collected data. The essential elements of either of the two instruments include a gamma detector array, signal conditioning electronics, digital alarm logic circuitry, power supplies, a microwave occupancy monitor, surveillance camera, irreversible electromechanical counters, and the appropriate tamper indicating envelope protecting these elements. Attempts to penetrate the tamper indicating envelope require material removal, and undetectable repair is very difficult, if not impossible. The techniques for joining major subassemblies and providing unique seals are also described. The personnel doorway uses a double pole array of NaI(Tl) detectors, and outputs are taken from a single channel pulse height analyzer with a window set at 60 to 250 keV and the lower level discriminator at greater than 60 keV. A sliding interval counter is used to make comparisons to an accumulated background at the 4sigma level. Logic design, sensitivity for special nuclear materials, false alarm data, and test procedures are described in detail. The shipping dock monitor had different design constraints and therefore uses a single, long, cylindrical plastic scintillator. Some differences in signal conditioning and processing are also described. (auth)

  4. Tritium instrumentation for a fusion reactor power plant

    International Nuclear Information System (INIS)

    Shank, K.E.; Easterly, C.E.

    1976-09-01

    A review of tritium instrumentation is presented. This includes a discussion of currently available in-plant instrumentation and methods required for sampling stacks, monitoring process streams and reactor coolants, analyzing occupational work areas for air and surface contamination, and personnel monitoring. Off-site instrumentation and collection techniques are also presented. Conclusions are made concerning the adequacy of existing instrumentation in relation to the monitoring needs for fusion reactors

  5. Development of an instrument for community-level health related social capital among Japanese older people: The JAGES Project.

    Science.gov (United States)

    Saito, Masashige; Kondo, Naoki; Aida, Jun; Kawachi, Ichiro; Koyama, Shihoko; Ojima, Toshiyuki; Kondo, Katsunori

    2017-05-01

    We developed and validated an instrument to measure community-level social capital based on data derived from older community dwellers in Japan. We used cross-sectional data from the Japan Gerontological Evaluation Study, a nationwide survey involving 123,760 functionally independent older people nested within 702 communities (i.e., school districts). We conducted exploratory and confirmatory factor analyses on survey items to determine the items in a multi-dimensional scale to measure community social capital. Internal consistency was checked with Cronbach's alpha. Convergent construct validity was assessed via correlating the scale with health outcomes. From 53 candidate variables, 11 community-level variables were extracted: participation in volunteer groups, sports groups, hobby activities, study or cultural groups, and activities for teaching specific skills; trust, norms of reciprocity, and attachment to one's community; received emotional support; provided emotional support; and received instrumental support. Using factor analysis, these variables were determined to belong to three sub-scales: civic participation (eigenvalue = 3.317, α = 0.797), social cohesion (eigenvalue = 2.633, α = 0.853), and reciprocity (eigenvalue = 1.424, α = 0.732). Confirmatory factor analysis indicated the goodness of fit of this model. Multilevel Poisson regression analysis revealed that civic participation score was robustly associated with individual subjective health (Self-Rated Health: prevalence ratio [PR] 0.96; 95% confidence interval [CI], 0.94-0.98; Geriatric Depression Scale [GDS]: PR 0.95; 95% CI, 0.93-0.97). Reciprocity score was also associated with individual GDS (PR 0.98; 95% CI, 0.96-1.00). Social cohesion score was not consistently associated with individual health indicators. Our scale for measuring social capital at the community level might be useful for future studies of older community dwellers. Copyright © 2016 The Authors. Production and

  6. Development of an instrument for community-level health related social capital among Japanese older people: The JAGES Project

    Directory of Open Access Journals (Sweden)

    Masashige Saito

    2017-05-01

    Full Text Available Background: We developed and validated an instrument to measure community-level social capital based on data derived from older community dwellers in Japan. Methods: We used cross-sectional data from the Japan Gerontological Evaluation Study, a nationwide survey involving 123,760 functionally independent older people nested within 702 communities (i.e., school districts. We conducted exploratory and confirmatory factor analyses on survey items to determine the items in a multi-dimensional scale to measure community social capital. Internal consistency was checked with Cronbach's alpha. Convergent construct validity was assessed via correlating the scale with health outcomes. Results: From 53 candidate variables, 11 community-level variables were extracted: participation in volunteer groups, sports groups, hobby activities, study or cultural groups, and activities for teaching specific skills; trust, norms of reciprocity, and attachment to one's community; received emotional support; provided emotional support; and received instrumental support. Using factor analysis, these variables were determined to belong to three sub-scales: civic participation (eigenvalue = 3.317, α = 0.797, social cohesion (eigenvalue = 2.633, α = 0.853, and reciprocity (eigenvalue = 1.424, α = 0.732. Confirmatory factor analysis indicated the goodness of fit of this model. Multilevel Poisson regression analysis revealed that civic participation score was robustly associated with individual subjective health (Self-Rated Health: prevalence ratio [PR] 0.96; 95% confidence interval [CI], 0.94–0.98; Geriatric Depression Scale [GDS]: PR 0.95; 95% CI, 0.93–0.97. Reciprocity score was also associated with individual GDS (PR 0.98; 95% CI, 0.96–1.00. Social cohesion score was not consistently associated with individual health indicators. Conclusions: Our scale for measuring social capital at the community level might be useful for future studies of older community dwellers.

  7. Segmental and global lordosis changes with two-level axial lumbar interbody fusion and posterior instrumentation

    Science.gov (United States)

    Melgar, Miguel A; Tobler, William D; Ernst, Robert J; Raley, Thomas J; Anand, Neel; Miller, Larry E; Nasca, Richard J

    2014-01-01

    Background Loss of lumbar lordosis has been reported after lumbar interbody fusion surgery and may portend poor clinical and radiographic outcome. The objective of this research was to measure changes in segmental and global lumbar lordosis in patients treated with presacral axial L4-S1 interbody fusion and posterior instrumentation and to determine if these changes influenced patient outcomes. Methods We performed a retrospective, multi-center review of prospectively collected data in 58 consecutive patients with disabling lumbar pain and radiculopathy unresponsive to nonsurgical treatment who underwent L4-S1 interbody fusion with the AxiaLIF two-level system (Baxano Surgical, Raleigh NC). Main outcomes included back pain severity, Oswestry Disability Index (ODI), Odom's outcome criteria, and fusion status using flexion and extension radiographs and computed tomography scans. Segmental (L4-S1) and global (L1-S1) lumbar lordosis measurements were made using standing lateral radiographs. All patients were followed for at least 24 months (mean: 29 months, range 24-56 months). Results There was no bowel injury, vascular injury, deep infection, neurologic complication or implant failure. Mean back pain severity improved from 7.8±1.7 at baseline to 3.3±2.6 at 2 years (p lordosis, defined as a change in Cobb angle ≤ 5°, was identified in 84% of patients at L4-S1 and 81% of patients at L1-S1. Patients with loss or gain in segmental or global lordosis experienced similar 2-year outcomes versus those with less than a 5° change. Conclusions/Clinical Relevance Two-level axial interbody fusion supplemented with posterior fixation does not alter segmental or global lordosis in most patients. Patients with postoperative change in lordosis greater than 5° have similarly favorable long-term clinical outcomes and fusion rates compared to patients with less than 5° lordosis change. PMID:25694920

  8. A new time-of-flight instrument for quantitative surface analysis

    International Nuclear Information System (INIS)

    Veryovkin, Igor V.; Calaway, Wallis F.; Moore, Jerry F.; Pellin, Michael J.; Burnett, Donald S.

    2004-01-01

    A new generation of time-of-flight mass spectrometers that implement ion sputtering and laser desorption for probing solid samples and can operate in regimes of laser post-ionization secondary neutral mass spectrometry and secondary ion mass spectrometry is being developed at Argonne National Laboratory. These new instruments feature novel ion optical systems for efficient extraction of ions from large laser post-ionization volumes and for lossless transport of these ions to detectors. Another feature of this design is a new in-vacuum all-reflecting optical microscope with 0.5-μm resolution. Advanced ion and light optics and three ion sources, including a liquid metal ion gun (focusable to 50 nm) and a low energy ion gun, give rise to an instrument capable of quantitative analyses of samples for the most challenging applications, such as determining elemental concentrations in shallow implants at ultra-trace levels (for example, solar wind samples delivered by NASA Genesis mission) and analyzing individual sub-micrometer particles on a sample stage (such as, interstellar dust delivered by NASA Stardust mission). Construction of a prototype instrument has been completed and testing is underway. A more advanced instrument of similar design is under construction. The overall design of the new instrument and the innovations that make it unique are outlined. Results of the first tests to characterize its analytical capabilities are presented also

  9. A systematic review of instruments that measure attitudes toward homosexual men.

    Science.gov (United States)

    Grey, Jeremy A; Robinson, Beatrice Bean E; Coleman, Eli; Bockting, Walter O

    2013-01-01

    Scientific interest in the measurement of homophobia and internalized homophobia has grown over the past 30 years, and new instruments and terms have emerged. To help researchers with the challenging task of identifying appropriate measures for studies in sexual-minority health, we reviewed measures of homophobia published in the academic literature from 1970 to 2012. Instruments that measured attitudes toward male homosexuals/homosexuality or measured homosexuals' internalized attitudes toward homosexuality were identified using measurement manuals and a systematic review. A total of 23 instruments met criteria for inclusion, and their features were summarized and compared. All 23 instruments met minimal criteria for adequate scale construction, including scale development, sampling, reliability, and evidence of validity. Validity evidence was diverse and was categorized as interaction with gay men, HIV/AIDS variables, mental health, and conservative religious or political beliefs. Homophobia was additionally correlated with authoritarianism and bias, gender ideology, gender differences, and reactions to homosexual stimuli. Internalized homophobia was validated by examining relationships with disclosing one's homosexuality and level of homosexual identity development. We hope this review will make the process of instrument selection more efficient by allowing researchers to easily locate, evaluate, and choose the proper measure based on their research question and population of interest.

  10. Final draft position on geotechnical instrumentation in a salt repository environment: Requirements, performance, recommendations, and development needs

    International Nuclear Information System (INIS)

    1987-07-01

    This report presents the results of a study of the present status of geotechnical instrumentation with respect to potential use in an underground test facility at a candidate nuclear waste repository site in salt. Programmatic factors that have a general impact on the success of underground instrumentation are discussed. Performance requirements relating to accuracy, temperature range, longevity, and capability for automation are established on the basis of criteria proposed for other rock types, perceived needs of the Site Characterization Program, and the authors' experience and judgment. Test site conditions are discussed including underground logistics, corrosion, and other factors that affect instrument reliability. The status of existing instrumentation for measuring deformation, stress, temperature, fluid pressure, acoustic emission, and other less critical parameters is presented. For each instrument not presently capable of satisfying its associated performance requirements, specific development needs and possible approaches are identified, and necessary testing is describe to a conceptual level of detail. A brief discussion of instrument considerations relating to automatic data acquisition is also included. The position of instrument development as a key activity on the critical path under current schedules for the Site Characterization Program is discussed. Annotated references and reports on site visits and meetings used as the data base in evaluating present instrument status are appended to this report. 110 refs., 14 figs., 26 tabs

  11. Marketing instruments of foreign trade promotion

    Directory of Open Access Journals (Sweden)

    Bjelić Predrag

    2011-01-01

    Full Text Available Instruments of promotion as a part of marketing mix are usually associated with companies but more and more countries use this instrument in order to boost their exports. These foreign trade promotion instruments are now popular in many countries in the world since their use is not opposed to any World Trade Organization rules. Marketing instruments of trade promotions are the most important. They include National Exhibitions and National labels of origin and quality. In order to coordinate the application of these instruments countries have established national bodies for trade promotion. Many studies in the past had argued that national Agencies established to promote export did not had any real success, but recent studies indicate that they could have a significant impact on country export promotion. The result of this rise in impact of national export promotion agencies is due to international effort spearheaded by International Trade Center. The aim of this paper is to point out types and methods of marketing instruments application in trade promotion and to present the effectiveness of these instruments applications.

  12. Instrument evaluation no. 18. Mini instruments contamination meter type 5.10 EL

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1980-04-01

    An evaluation is given of the general purpose contamination monitor, the Mini-Instruments Type 5-10EL which comprises a probe connected by a coiled extensible cable to a ratemeter. The facilities and controls, radiation characteristics, electrical characteristics, environmental effects, mechanical characteristics, and the manual are considered. A summary is given of the instrument's performance showing that it is a useful general-purpose contamination monitor suitable for the monitoring of beta contamination at a level for non-active areas of 1 DL (3.7 Bq cm -2 (10 -4 μCi cm -2 )) for beta emitters of maximum energy at least that of 14 C, given a normal environmental gamma background. (U.K.)

  13. 18 CFR 367.2440 - Account 244, Derivative instrument liabilities.

    Science.gov (United States)

    2010-04-01

    ..., Derivative instrument liabilities. This account must include the change in the fair value of all derivative instrument liabilities not designated as cash flow or fair value hedges. Account 426.5, Other deductions... the fair value of the derivative instrument. ...

  14. Levelling the playing field? The influence of national wind power planning instruments on conflicts of interests in a Swedish county

    International Nuclear Information System (INIS)

    Bergek, Anna

    2010-01-01

    Slow and complicated wind power planning and permitting procedures have been a large obstacle for wind power diffusion in Sweden and other countries. This paper complements previous siting-oriented literature with a planning perspective on these problems. The focus is two national planning instruments implemented in Sweden in the early 2000s: a national planning target and an appointment of areas of national interest for wind power. The paper identifies different types of conflicts of interest related to wind power - in addition to the conflict between wind power as a national public interest and various local private interests - and analyses the impact of the national planning instruments on the handling of these conflicts in the land-use planning process in the County of Ostergoetland. The analysis shows that the planning target actually made local planning officials even more inclined to treat wind power as a private rather than a public interest and that the method used to identify areas of national interest of wind power forced wind power to compete with the combined strengths of all other public interest. The planning instruments thus left wind power to fight an uphill battle rather than to meet other interests face-to-face on a level playing field.

  15. Energy-efficiency instruments in the electricity area; Instrumente fuer Energieeffizienz im Elektrizitaetsbereich. Auslaendische Erfahrungen und Instrumenten-Mix fuer die Schweiz

    Energy Technology Data Exchange (ETDEWEB)

    Hammer, S; Oettli, B; Schneider, Ch; Iten, R [Infras, Zuerich (Switzerland); Peherstorfer, N [Oesterreichische Energieagentur, Wien (Austria)

    2007-06-15

    This comprehensive report for the Swiss Federal Office of Energy (SFOE) describes a mix of instruments that could increase the efficiency of electricity usage in Switzerland. The basis for the development of these instruments - the experience gained in Europe in this area - is discussed. Explicitly not discussed are energy and electricity steering taxes, which could also be part of a future instrument-mix. The measures suggested include the setting of compulsory long-term reduction targets that are to form the basis for strategies and measures to be taken in particular areas and the development of an appropriate instrument-mix for this purpose. These could include regulations and labels, a national fund and certificate trading. Suppliers of electricity could be committed to increasing the efficiency of electricity use and national programmes could also attempt to influence consumer habits. The instruments should, according to the authors, be based on the existing legal framework and use know-how and structures that are already available.

  16. Virtual Reality Musical Instruments

    DEFF Research Database (Denmark)

    Serafin, Stefania; Erkut, Cumhur; Kojs, Juraj

    2016-01-01

    The rapid development and availability of low-cost technologies have created a wide interest in virtual reality. In the field of computer music, the term “virtual musical instruments” has been used for a long time to describe software simulations, extensions of existing musical instruments......, and ways to control them with new interfaces for musical expression. Virtual reality musical instruments (VRMIs) that include a simulated visual component delivered via a head-mounted display or other forms of immersive visualization have not yet received much attention. In this article, we present a field...

  17. Instrumentation

    International Nuclear Information System (INIS)

    Prieur, G.; Nadi, M.; Hedjiedj, A.; Weber, S.

    1995-01-01

    This second chapter on instrumentation gives little general consideration on history and classification of instrumentation, and two specific states of the art. The first one concerns NMR (block diagram of instrumentation chain with details on the magnets, gradients, probes, reception unit). The first one concerns precision instrumentation (optical fiber gyro-meter and scanning electron microscope), and its data processing tools (programmability, VXI standard and its history). The chapter ends with future trends on smart sensors and Field Emission Displays. (D.L.). Refs., figs

  18. A statistical approach to instrument calibration

    Science.gov (United States)

    Robert R. Ziemer; David Strauss

    1978-01-01

    Summary - It has been found that two instruments will yield different numerical values when used to measure identical points. A statistical approach is presented that can be used to approximate the error associated with the calibration of instruments. Included are standard statistical tests that can be used to determine if a number of successive calibrations of the...

  19. A Systematic Review of Instruments to Assess Organizational Readiness for Knowledge Translation in Health Care

    Science.gov (United States)

    Gagnon, Marie-Pierre; Attieh, Randa; Ghandour, El Kebir; Légaré, France; Ouimet, Mathieu; Estabrooks, Carole A.; Grimshaw, Jeremy

    2014-01-01

    Background The translation of research into practices has been incomplete. Organizational readiness for change (ORC) is a potential facilitator of effective knowledge translation (KT). However we know little about the best way to assess ORC. Therefore, we sought to systematically review ORC measurement instruments. Methods We searched for published studies in bibliographic databases (Pubmed, Embase, CINAHL, PsychINFO, Web of Science, etc.) up to November 1st, 2012. We included publications that developed ORC measures and/or empirically assessed ORC using an instrument at the organizational level in the health care context. We excluded articles if they did not refer specifically to ORC, did not concern the health care domain or were limited to individual-level change readiness. We focused on identifying the psychometric properties of instruments that were developed to assess readiness in an organization prior to implementing KT interventions in health care. We used the Standards for Educational and Psychological Testing to assess the psychometric properties of identified ORC measurement instruments. Findings We found 26 eligible instruments described in 39 publications. According to the Standards for Educational and Psychological Testing, 18 (69%) of a total of 26 measurement instruments presented both validity and reliability criteria. The Texas Christian University –ORC (TCU-ORC) scale reported the highest instrument validity with a score of 4 out of 4. Only one instrument, namely the Modified Texas Christian University – Director version (TCU-ORC-D), reported a reliability score of 2 out of 3. No information was provided regarding the reliability and validity of five (19%) instruments. Conclusion Our findings indicate that there are few valid and reliable ORC measurement instruments that could be applied to KT in the health care sector. The TCU-ORC instrument presents the best evidence in terms of validity testing. Future studies using this instrument could

  20. Advanced optical instruments technology

    Science.gov (United States)

    Shao, Mike; Chrisp, Michael; Cheng, Li-Jen; Eng, Sverre; Glavich, Thomas; Goad, Larry; Jones, Bill; Kaarat, Philip; Nein, Max; Robinson, William

    1992-08-01

    The science objectives for proposed NASA missions for the next decades push the state of the art in sensitivity and spatial resolution over a wide range of wavelengths, including the x-ray to the submillimeter. While some of the proposed missions are larger and more sensitive versions of familiar concepts, such as the next generation space telescope, others use concepts, common on the Earth, but new to space, such as optical interferometry, in order to provide spatial resolutions impossible with other concepts. However, despite their architecture, the performance of all of the proposed missions depends critically on the back-end instruments that process the collected energy to produce scientifically interesting outputs. The Advanced Optical Instruments Technology panel was chartered with defining technology development plans that would best improve optical instrument performance for future astrophysics missions. At this workshop the optical instrument was defined as the set of optical components that reimage the light from the telescope onto the detectors to provide information about the spatial, spectral, and polarization properties of the light. This definition was used to distinguish the optical instrument technology issues from those associated with the telescope, which were covered by a separate panel. The panel identified several areas for optical component technology development: diffraction gratings; tunable filters; interferometric beam combiners; optical materials; and fiber optics. The panel also determined that stray light suppression instruments, such as coronagraphs and nulling interferometers, were in need of general development to support future astrophysics needs.

  1. The Optical Instrumentation of the ATLAS Tile Calorimeter

    CERN Document Server

    Abdallah, J; Alexa, C; Alves, R; Amaral, P; Ananiev, A; Anderson, K; Andresen, X; Antonaki, A; Batusov, V; Bednar, P; Bergeaas, E; Biscarat, C; Blanch, O; Blanchot, G; Bohm, C; Boldea, V; Bosi, F; Bosman, M; Bromberg, C; Budagov, Yu A; Calvet, D; Cardeira, C; Carli, T; Carvalho, J; Cascella, M; Castillo, M V; Costelo, J; Cavalli-Sforza, M; Cavasinni, V; Cerqueira, A S; Clément, C; Cobal, M; Cogswell, F; Constantinescu, S; Costanzo, D; Da Silva, P; David, M; Davidek, T; Dawson, J; De, K; Del Prete, T; Diakov, E; Di Girolamo, B; Dita, S; Dolejsi, J; Dolezal, Z; Dotti, A; Downing, R; Drake, G; Efthymiopoulos, I; Errede, D; Errede, S; Farbin, A; Fassouliotis, D; Feng, E; Fenyuk, A; Ferdi, C; Ferreira, B C; Ferrer, A; Flaminio, V; Flix, J; Francavilla, P; Fullana, E; Garde, V; Gellerstedt, K; Giakoumopoulou, V; Giangiobbe, V; Gildemeister, O; Gilewsky, V; Giokaris, N; Gollub, N; Gomes, A; González, V; Gouveia, J; Grenier, P; Gris, P; Guarino, V; Guicheney, C; Sen-Gupta, A; Hakobyan, H; Haney, M; Hellman, S; Henriques, A; Higón, E; Hill, N; Holmgren, S; Hruska, I; Hurwitz, M; Huston, J; Jen-La Plante, I; Jon-And, K; Junk, T; Karyukhin, A; Khubua, J; Klereborn, J; Konsnantinov, V; Kopikov, S; Korolkov, I; Krivkova, P; Kulchitsky, Y; Kurochkin, Yu; Kuzhir, P; Lapin, V; Le Compte, T; Lefèvre, R; Leitner, R; Li, J; Liablin, M; Lokajícek, M; Lomakin, Y; Lourtie, P; Lovas, L; Lupi, A; Maidantchik, C; Maio, A; Maliukov, S; Manousakis, A; Marques, C; Marroquim, F; Martin, F; Mazzoni, E; Merritt, F S; Myagkov, A; Miller, R; Minashvili, I; Miralles, L; Montarou, G; Némécek, S; Nessi, M; Nikitine, I; Nodulman, L; Norniella, O; Onofre, A; Oreglia, M; Palan, B; Pallin, D; Pantea, D; Pereira, A; Pilcher, J E; Pina, J; Pinhão, J; Pod, E; Podlyski, F; Portell, X; Poveda, J; Pribyl, L; Price, L E; Proudfoot, J; Ramalho, M; Ramstedt, M; Raposeiro, L; Reis, J; Richards, R; Roda, C; Romanov, V; Rosnet, R; Roy, P; Ruiz, A; Rumiantsau, V; Russakovich, N; Sada Costa, J; Salto, O; Salvachúa, B; Sanchis, E; Sanders, H; Santoni, C; Santos, J; Saraiva, J G; Sarri, F; Says, L P; Schlager, G; Schlereth, J L; Seixas, J M; Selldén, B; Shalanda, N; Shevtsov, P; Shochet, M; Silva, J; Simaitis, V; Simonyan, M; Sisakian, A; Sjölin, J; Solans, C; Solodkov, A; Solovyanov, O; Sosebee, M; Spanó, F; Speckmeyer, P; Stanek, R; Starchenko, E; Starovoitov, P; Suk, M; Sykora, I; Tang, F; Tas, P; Teuscher, R; Tischenko, M; Tokar, S; Topilin, N; Torres, J; Underwood, D; Usai, G; Valero, A; Valkár, S; Valls, J A; Vartapetian, A; Vazielle, F; Vellidis, C; Ventura, F; Vichou, I; Vivarelli, I; Volpi, M; White, A; Zaitsev, A; Zaytsev, Yu; Zenin, A; Zenis, T; Zenonos, Z; Zenz, S; Zilka, B

    2013-01-01

    The purpose of this Note is to describe the optical assembly procedure called here Optical Instrumentation and the quality tests conducted on the assembled units. Altogether, 65 Barrel (or LB) modules were constructed - including one spare - together with 129 Extended Barrel (EB) modules (including one spare). The LB modules were mechanically assembled at JINR (Dubna, Russia) and transported to CERN, where the optical instrumentation was performed with personnel contributed by several Institutes. The modules composing one of the two Extended Barrels (known as EBA) were mechanically assembled in the USA, and instrumented in two US locations (ANL, U. of Michigan), while the modules of the other Extended barrel (EBC) were assembled in Spain and instrumented at IFAE (Barcelona). Each of the EB modules includes a subassembly known as ITC that contributes to the hermeticity of the calorimeter; all ITCs were assembled at UTA (Texas), and mounted onto the module mechanical structures at the EB mechanical assembly loc...

  2. Slit-scanning technique using standard cell sorter instruments for analyzing and sorting nonacrocentric human chromosomes, including small ones

    NARCIS (Netherlands)

    Rens, W.; van Oven, C. H.; Stap, J.; Jakobs, M. E.; Aten, J. A.

    1994-01-01

    We have investigated the performance of two types of standard flow cell sorter instruments, a System 50 Cytofluorograph and a FACSTar PLUS cell sorter, for the on-line centromeric index (CI) analysis of human chromosomes. To optimize the results, we improved the detection efficiency for centromeres

  3. Instrumentation Needs for Integral Primary System Reactors (IPSRs) - Task 1 Final Report

    International Nuclear Information System (INIS)

    Gary D Storrick; Bojan Petrovic; Luca Oriani; Lawrence E Conway; Diego Conti

    2005-01-01

    This report presents the results of the Westinghouse work performed under Task 1 of this Financial Assistance Award and satisfies a Level 2 Milestone for the project. While most of the signals required for control of IPSRs are typical of other PWRs, the integral configuration poses some new challenges in the design or deployment of the sensors/instrumentation and, in some cases, requires completely new approaches. In response to this consideration, the overall objective of Task 1 was to establish the instrumentation needs for integral reactors, provide a review of the existing solutions where available, and, identify research and development needs to be addressed to enable successful deployment of IPSRs. The starting point for this study was to review and synthesize general characteristics of integral reactors, and then to focus on a specific design. Due to the maturity of its design and availability of design information to Westinghouse, IRIS (International Reactor Innovative and Secure) was selected for this purpose. The report is organized as follows. Section 1 is an overview. Section 2 provides background information on several representative IPSRs, including IRIS. A review of the IRIS safety features and its protection and control systems is used as a mechanism to ensure that all critical safety-related instrumentation needs are addressed in this study. Additionally, IRIS systems are compared against those of current advanced PWRs. The scope of this study is then limited to those systems where differences exist, since, otherwise, the current technology already provides an acceptable solution. Section 3 provides a detailed discussion on instrumentation needs for the representative IPSR (IRIS) with detailed qualitative and quantitative requirements summarized in the exhaustive table included as Appendix A. Section 3 also provides an evaluation of the current technology and the instrumentation used for measurement of required parameters in current PWRs. Section 4

  4. Report of the Instrumentation Service - Annex C

    International Nuclear Information System (INIS)

    Mikic, N.; Majstorovic, D.

    1993-01-01

    This report describes the tasks and organizational structure of the Instrumentation service. The most important task of this Service is control and maintenance of the reactor control and protection instruments, operation control, and dosimetry system. Besides data about this basic instrumentation, the report includes data about control and maintenance of other electronic equipment, inspection of the reactor vessel and spent fuel storage pool and describes activities related to renewal of the equipment [sr

  5. Report of the Instrumentation Service - Annex C

    International Nuclear Information System (INIS)

    Mikic, N.

    1999-01-01

    This report describes the tasks and organizational structure of the Instrumentation service. The most important task of this Service is control and maintenance of the reactor control and protection instruments, operation control, and dosimetry system. Besides data about this basic instrumentation, the report includes data about control and maintenance of other electronic equipment, inspection of the reactor vessel and spent fuel storage pool and describes activities related control and maintenace of the experimental devices [sr

  6. Report of the Instrumentation Service - Annex C

    International Nuclear Information System (INIS)

    Mikic, N.

    2000-01-01

    This report describes the tasks and organizational structure of the Instrumentation service. The most important task of this Service is control and maintenance of the reactor control and protection instruments, operation control, and dosimetry system. Besides data about this basic instrumentation, the report includes data about control and maintenance of other electronic equipment, inspection of the reactor vessel and spent fuel storage pool and describes activities related control and maintenace of the experimental devices [sr

  7. Report of the Instrumentation Service - Annex C

    International Nuclear Information System (INIS)

    Majstorovic, D.

    1986-01-01

    This report describes the tasks and organizational structure of the Instrumentation service. The most important task of this Service is control and maintenance of the reactor control and protection instruments, operation control, and dosimetry system. Besides data about this basic instrumentation, the report includes data about control and maintenance of other electronic equipment, inspection of the reactor vessel and spent fuel storage pool and describes activities related to renewal of the equipment [sr

  8. Report of the Instrumentation Service - Annex C

    International Nuclear Information System (INIS)

    Majstorovic, D.

    1988-01-01

    This report describes the tasks and organizational structure of the Instrumentation service. The most important task of this Service is control and maintenance of the reactor control and protection instruments, operation control, and dosimetry system. Besides data about this basic instrumentation, the report includes data about control and maintenance of other electronic equipment, inspection of the reactor vessel and spent fuel storage pool and describes activities related to renewal of the equipment [sr

  9. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2001-04-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor.

  10. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2001-01-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor

  11. Glide path preparation in S-shaped canals with rotary pathfinding nickel-titanium instruments.

    Science.gov (United States)

    Ajuz, Natasha C C; Armada, Luciana; Gonçalves, Lucio S; Debelian, Gilberto; Siqueira, José F

    2013-04-01

    This study compared the incidence of deviation along S-shaped (double-curved) canals after glide path preparation with 2 nickel-titanium (NiTi) rotary pathfinding instruments and hand K-files. S-shaped canals from 60 training blocks were filled with ink, and preinstrumentation images were obtained by using a stereomicroscope. Glide path preparation was performed by an endodontist who used hand stainless steel K-files (up to size 20), rotary NiTi PathFile instruments (up to size 19), or rotary NiTi Scout RaCe instruments (up to size 20). Postinstrumentation images were taken by using exactly the same conditions as for the preinstrumentation images, and both pictures were superimposed. Differences along the S-shaped canal for the mesial and distal aspects were measured to evaluate the occurrence of deviation. Intragroup analysis showed that all instruments promoted some deviation in virtually all levels. Overall, regardless of the group, deviations were observed in the mesial wall at the canal terminus and at levels 4, 5, 6 and 7 mm and in the distal wall at levels 1, 2, and 3 mm. These levels corresponded to the inner walls of each curvature. Both rotary NiTi instruments performed significantly better than hand K-files at all levels (P instruments showed significantly better results than PathFiles at levels 0, 2, 3, 5, and 6 mm (P rotary NiTi instruments are suitable for adequate glide path preparation because they promoted less deviation from the original canal anatomy when compared with hand-operated instruments. Of the 2 rotary pathfinding instruments, Scout RaCe showed an overall significantly better performance. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  12. Two new portable survey instruments: the field phoswich detector and the Wee Pee Pee

    International Nuclear Information System (INIS)

    Umbarger, C.J.; Wolf, M.A.

    1978-01-01

    As part of a continuing program to upgrade the health physics survey instrumentation at Los Alamos, we have recently developed two new portable instruments. The first is a fully portable phoswich detector for low energy photons from small amounts of plutonium and americium in the field. The instrument has a background that is 2 to 3 times lower than an equivalent thin NaI detector. The instrument features an aural popper, analogue rate meter, and timer/scaler with liquid crystal display. The second instrument, called the ''Wee Pee Wee,'' is an alpha air proportional probe with complete electronics and readout package mounted on the probe itself. The entire package has a mass of 0.66 kg (1.45 lb) and is carried and operated in one hand. For monitoring shoes and other places where it is difficult to read the count-rate meter, the meter is made detachable for clipping to a shirt pocket, etc. An audio popper, range scales to 100 K cpm, and visual checks for high voltage and battery levels are also included

  13. LOFT instrumented fuel design and operating experience

    International Nuclear Information System (INIS)

    Russell, M.L.

    1979-01-01

    A summary description of the Loss-of-Fluid Test (LOFT) system instrumented core construction details and operating experience through reactor startup and loss-of-coolant experiment (LOCE) operations performed to date are discussed. The discussion includes details of the test instrumentation attachment to the fuel assembly, the structural response of the fuel modules to the forces generated by a double-ended break of a pressurized water reactor (PWR) coolant pipe at the inlet to the reactor vessel, the durability of the LOFT fuel and test instrumentation, and the plans for incorporation of improved fuel assembly test instrumentation features in the LOFT core

  14. Cross-cultural adaptation of instruments assessing breastfeeding determinants: a multi-step approach

    Science.gov (United States)

    2014-01-01

    Background Cross-cultural adaptation is a necessary process to effectively use existing instruments in other cultural and language settings. The process of cross-culturally adapting, including translation, of existing instruments is considered a critical set to establishing a meaningful instrument for use in another setting. Using a multi-step approach is considered best practice in achieving cultural and semantic equivalence of the adapted version. We aimed to ensure the content validity of our instruments in the cultural context of KwaZulu-Natal, South Africa. Methods The Iowa Infant Feeding Attitudes Scale, Breastfeeding Self-Efficacy Scale-Short Form and additional items comprise our consolidated instrument, which was cross-culturally adapted utilizing a multi-step approach during August 2012. Cross-cultural adaptation was achieved through steps to maintain content validity and attain semantic equivalence in the target version. Specifically, Lynn’s recommendation to apply an item-level content validity index score was followed. The revised instrument was translated and back-translated. To ensure semantic equivalence, Brislin’s back-translation approach was utilized followed by the committee review to address any discrepancies that emerged from translation. Results Our consolidated instrument was adapted to be culturally relevant and translated to yield more reliable and valid results for use in our larger research study to measure infant feeding determinants effectively in our target cultural context. Conclusions Undertaking rigorous steps to effectively ensure cross-cultural adaptation increases our confidence that the conclusions we make based on our self-report instrument(s) will be stronger. In this way, our aim to achieve strong cross-cultural adaptation of our consolidated instruments was achieved while also providing a clear framework for other researchers choosing to utilize existing instruments for work in other cultural, geographic and population

  15. Emission inventory: An urban public policy instrument and benchmark

    International Nuclear Information System (INIS)

    D'Avignon, Alexander; Azevedo Carloni, Flavia; Lebre La Rovere, Emilio; Burle Schmidt Dubeux, Carolina

    2010-01-01

    Global concern with climate change has led to the development of a variety of solutions to monitor and reduce emissions on both local and global scales. Under the United Nations Framework Convention on Climate Change (UNFCCC), both developed and emerging countries have assumed responsibility for developing and updating national inventories of greenhouse gas emissions from anthropic sources. This creates opportunities and incentives for cities to carry out their own local inventories and, thereby, develop air quality management plans including both essential key players and stakeholders at the local level. The aim of this paper is to discuss the role of local inventories as an urban public policy instrument and how this type of local instrument may bring advantages countrywide in enhancing the global position of a country. Local inventories have been carried out in many cities of the world and the main advantage of this is that it allows an overview of emissions produced by different municipal activities, thereby, helps decision makers in the elaboration of efficient air quality management plans. In that way, measures aimed at the reduction of fossil fuel consumption to lower local atmospheric pollution levels can also, in some ways, reduce GHG emissions.

  16. Adjustable extender for instrument module

    International Nuclear Information System (INIS)

    Sevec, J.B.; Stein, A.D.

    1975-01-01

    A blank extender module used to mount an instrument module in front of its console for repair or test purposes has been equipped with a rotatable mount and means for locking the mount at various angles of rotation for easy accessibility. The rotatable mount includes a horizontal conduit supported by bearings within the blank module. The conduit is spring-biased in a retracted position within the blank module and in this position a small gear mounted on the conduit periphery is locked by a fixed pawl. The conduit and instrument mount can be pulled into an extended position with the gear clearing the pawl to permit rotation and adjustment of the instrument

  17. DEVELOPING MUSHROOM GYMNASTIC INSTRUMENT PROTOTYPE FOR MEN’S ARTISTIC GYMNASTIC SPORT IN CENTRAL JAVA PROVINCE

    Directory of Open Access Journals (Sweden)

    Tommy Soenyoto

    2014-03-01

    Full Text Available This study aims to develop mushroom gymnastic instrument for men’s artistic gymnastic athletes of junior and senior levels. The instrument is aimed at improving movement skills on horse saddle. Aside from its use as an exercise instrument for beginner, junior and senior levels of men’s artistic gymnastic athletes, this instrument can also be used for beginners’ level competition. This study used qualitative approach in which the data are collected from the initial step to the trial. The main procedure involved five steps: (1 the analysis of product development; (2 the development of initial product; (3 the expert validation; (4 the trial; and (5 the product revision. This study found that the mushroom gymnastic instrument can be used for men’s artistic gymnastic sport, particularly (1 for improving movement skill development on horse saddle for junior and senior athletes; (2 as an exercise instrument for beginner, junior and senior level of men’s artistic gymnastic athletes; (3 as an instrument used in competition for men’s artistic gymnastic for beginners’ level.

  18. The use of instruments of logistics and marketing in transport enterprises in lubuskie voivodeship

    Directory of Open Access Journals (Sweden)

    Agnieszka Perzyńska

    2016-09-01

    Full Text Available Background: The aim of the article is to verify the logistics and marketing instruments used in transport enterprises in Lubuskie voivodeship. The article presents the results of surveys of transport companies. Based on these studies in transport enterprises in Lubuskie, the current level of the use of logistics and marketing instruments was determined. Logistics and marketing instruments were separated to study the needs of transport companies in Lubuskie voivodeship. The choice of these instruments gave rise to a study f the possibility of using them in the implementation of business operations. From the findings it can be inferred that they are useful for the voivodeship, and that such a system can be implemented in the whole country. Methods: The study was conducted in the second half of 2014 and 140 transport enterprises in Lubuskie. Based on the research results, classifications of instruments were developed using logistics and marketing division at their levels. Results: On the basis of these findings and observations, the authors have analysed the levels of identification instruments, logistics and marketing. On this basis, it was possible to identify the instruments used by logistics and marketing in these companies. Conclusions: Based on the study of transport companies in Lubuskie voivodeship, a selection of logistics and marketing instruments were identified, along with a classification of the logistics and marketing instruments used. With the implementation of the above steps to classify the usage level of logistics and marketing instruments, the ability to match these levels to data transport companies was established.

  19. Special instrumentation developed for FARO and KROTOS FCI experiments: High temperature ultrasonic sensor and dynamic level sensor

    International Nuclear Information System (INIS)

    Huhtiniemi, I.; Jorzik, E.; Anselmi, M.

    1998-01-01

    Development and application of special instrumentation for FARO and KROTOS fuel-coolant interaction experiments at JRC-Ispra are described. A temperature sensor based on ultrasonic techniques is described with the discussion on the improvements in sensor fabrication technique and design. The sensor can be used to measure temperatures in the range from 1800 deg C to 3100 deg C with an accuracy of ± 50 deg C. The design allows local temperature measurements in multiple zones along the sensor element. This sensor has been used successfully in a number of FARO experiments where temperature distributions in molten corium pools have been measured. It will be also used in the future Phebus FP tests. Furthermore, a water level meter sensor based on the time domain reflectometry technique is described. This high speed sensor allows monitoring of liquid level under very demanding ambient conditions, as e.g. 5MPa, 550 K in FARO. This sensor has been successfully applied in a number of FARO and KROTOS tests where the water level rise caused by a molten corium and Al 2 O 3 pours have been measured. (author)

  20. Increasing Laser Stability with Improved Electronic Instruments

    Science.gov (United States)

    Troxel, Daylin; Bennett, Aaron; Erickson, Christopher J.; Jones, Tyler; Durfee, Dallin S.

    2010-03-01

    We present several electronic instruments developed to implement an ultra-stable laser lock. These instruments include a high speed, low noise homodyne photo-detector; an ultrahigh stability, low noise current driver with high modulation bandwidth and digital control; a high-speed, low noise PID controller; a low-noise piezo driver; and a laser diode temperature controller. We will present the theory of operation for these instruments, design and construction techniques, and essential characteristics for each device.

  1. The quality of systematic reviews of health-related outcome measurement instruments.

    Science.gov (United States)

    Terwee, C B; Prinsen, C A C; Ricci Garotti, M G; Suman, A; de Vet, H C W; Mokkink, L B

    2016-04-01

    Systematic reviews of outcome measurement instruments are important tools for the selection of instruments for research and clinical practice. Our aim was to assess the quality of systematic reviews of health-related outcome measurement instruments and to determine whether the quality has improved since our previous study in 2007. A systematic literature search was performed in MEDLINE and EMBASE between July 1, 2013, and June 19, 2014. The quality of the reviews was rated using a study-specific checklist. A total of 102 reviews were included. In many reviews the search strategy was considered not comprehensive; in only 59 % of the reviews a search was performed in EMBASE and in about half of the reviews there was doubt about the comprehensiveness of the search terms used for type of measurement instruments and measurement properties. In 41 % of the reviews, compared to 30 % in our previous study, the methodological quality of the included studies was assessed. In 58 %, compared to 55 %, the quality of the included instruments was assessed. In 42 %, compared to 7 %, a data synthesis was performed in which the results from multiple studies on the same instrument were somehow combined. Despite a clear improvement in the quality of systematic reviews of outcome measurement instruments in comparison with our previous study in 2007, there is still room for improvement with regard to the search strategy, and especially the quality assessment of the included studies and the included instruments, and the data synthesis.

  2. Instrumented Moles for Planetary Subsurface Regolith Studies

    Science.gov (United States)

    Richter, L. O.; Coste, P. A.; Grzesik, A.; Knollenberg, J.; Magnani, P.; Nadalini, R.; Re, E.; Romstedt, J.; Sohl, F.; Spohn, T.

    2006-12-01

    Soil-like materials, or regolith, on solar system objects provide a record of physical and/or chemical weathering processes on the object in question and as such possess significant scientific relevance for study by landed planetary missions. In the case of Mars, a complex interplay has been at work between impact gardening, aeolian as well as possibly fluvial processes. This resulted in regolith that is texturally as well as compositionally layered as hinted at by results from the Mars Exploration Rover (MER) missions which are capable of accessing shallow subsurface soils by wheel trenching. Significant subsurface soil access on Mars, i.e. to depths of a meter or more, remains to be accomplished on future missions. This has been one of the objectives of the unsuccessful Beagle 2 landed element of the ESA Mars Express mission having been equipped with the Planetary Underground Tool (PLUTO) subsurface soil sampling Mole system capable of self-penetration into regolith due to an internal electro-mechanical hammering mechanism. This lightweight device of less than 900 g mass was designed to repeatedly obtain and deliver to the lander regolith samples from depths down to 2 m which would have been analysed for organic matter and, specifically, organic carbon from potential extinct microbial activity. With funding from the ESA technology programme, an evolved Mole system - the Instrumented Mole System (IMS) - has now been developed to a readiness level of TRL 6. The IMS is to serve as a carrier for in situ instruments for measurements in planetary subsurface soils. This could complement or even eliminate the need to recover samples to the surface. The Engineering Model hardware having been developed within this effort is designed for accommodating a geophysical instrument package (Heat Flow and Physical Properties Package, HP3) that would be capable of measuring regolith physical properties and planetary heat flow. The chosen design encompasses a two-body Mole

  3. Practical course on reactor instrumentation

    International Nuclear Information System (INIS)

    Boeck, H.; Villa, M.

    2004-06-01

    This course is based on the description of the instrumentation of the TRIGA-reactor Vienna, which is used for training research and isotope production. It comprises the following chapters: 1. instrumentation, 2. calibration of the nuclear channels, 3. rod drop time of the control rods, 4. neutron flux density measurements using compensated ionization, 5. neutron flux density measurement with fission chambers (FC), 6. neutron flux density measurement with self-powered neutron detectors (SPND), 7. pressurized water reactor simulator, 8. verification of the radiation level during reactor operation. There is one appendix about neutron-sensitive thermocouples. (nevyjel)

  4. Standard NIM instrumentation system

    International Nuclear Information System (INIS)

    1990-05-01

    NIM is a standard modular instrumentation system that is in wide use throughout the world. As the NIM system developed and accommodations were made to a dynamic instrumentation field and a rapidly advancing technology, additions, revisions and clarifications were made. These were incorporated into the standard in the form of addenda and errata. This standard is a revision of the NIM document, AEC Report TID-20893 (Rev. 4) dated July 1974. It includes all the addenda and errata items that were previously issued as well as numerous additional items to make the standard current with modern technology and manufacturing practice

  5. Mobile device-based optical instruments for agriculture

    Science.gov (United States)

    Sumriddetchkajorn, Sarun

    2013-05-01

    Realizing that a current smart-mobile device such as a cell phone and a tablet can be considered as a pocket-size computer embedded with a built-in digital camera, this paper reviews and demonstrates on how a mobile device can be specifically functioned as a portable optical instrument for agricultural applications. The paper highlights several mobile device-based optical instruments designed for searching small pests, measuring illumination level, analyzing spectrum of light, identifying nitrogen status in the rice field, estimating chlorine in water, and determining ripeness level of the fruit. They are suitable for individual use as well as for small and medium enterprises.

  6. Precision Instrumentation Amplifiers and Read-Out Integrated Circuits

    CERN Document Server

    Wu, Rong; Makinwa, Kofi A A

    2013-01-01

    This book presents innovative solutions in the design of precision instrumentation amplifier and read-out ICs, which can be used to boost millivolt-level signals transmitted by modern sensors, to levels compatible with the input ranges of typical Analog-to-Digital Converters (ADCs).  The discussion includes the theory, design and realization of interface electronics for bridge transducers and thermocouples. It describes the use of power efficient techniques to mitigate low frequency errors, resulting in interface electronics with high accuracy, low noise and low drift. Since this book is mainly about techniques for eliminating low frequency errors, it describes the nature of these errors and the associated dynamic offset cancellation techniques used to mitigate them.  Surveys comprehensively offset cancellation and accuracy improvement techniques applied in precision amplifier designs; Presents techniques in precision circuit design to mitigate low frequency errors in millivolt-level signals transmitted by ...

  7. ExoMars Trace Gas Orbiter Instrument Modelling Approach to Streamline Science Operations

    Science.gov (United States)

    Munoz Fernandez, Michela; Frew, David; Ashman, Michael; Cardesin Moinelo, Alejandro; Garcia Beteta, Juan Jose; Geiger, Bernhard; Metcalfe, Leo; Nespoli, Federico; Muniz Solaz, Carlos

    2018-05-01

    ExoMars Trace Gas Orbiter (TGO) science operations activities are centralised at ESAC's Science Operations Centre (SOC). The SOC receives the inputs from the principal investigators (PIs) in order to implement and deliver the spacecraft pointing requests and instrument timelines to the Mission Operations Centre (MOC). The high number of orbits per planning cycle has made it necessary to abstract the planning interactions between the SOC and the PI teams at the observation level. This paper describes the modelling approach we have conducted for TGOís instruments to streamline science operations. We have created dynamic observation types that scale to adapt to the conditions specified by the PI teams including observation timing, and pointing block parameters calculated from observation geometry. This approach is considered and improvement with respect to previous missions where the generation of the observation pointing and commanding requests was performed manually by the instrument teams. Automation software assists us to effectively handle the high density of planned orbits with increasing volume of scientific data and to successfully meet opportunistic scientific goals and objectives. Our planning tool combines the instrument observation definition files provided by the PIs together with the flight dynamics products to generate the Pointing Requests and the instrument timeline (ITL). The ITL contains all the validated commands at the TC sequence level and computes the resource envelopes (data rate, power, data volume) within the constraints. At the SOC, our main goal is to maximise the science output while minimising the number of iterations among the teams, ensuring that the timeline does not violate the state transitions allowed in the Mission Operations Rules and Constraints Document.

  8. Method and apparatus for continuous fluid leak monitoring and detection in analytical instruments and instrument systems

    Science.gov (United States)

    Weitz, Karl K [Pasco, WA; Moore, Ronald J [West Richland, WA

    2010-07-13

    A method and device are disclosed that provide for detection of fluid leaks in analytical instruments and instrument systems. The leak detection device includes a collection tube, a fluid absorbing material, and a circuit that electrically couples to an indicator device. When assembled, the leak detection device detects and monitors for fluid leaks, providing a preselected response in conjunction with the indicator device when contacted by a fluid.

  9. Instrumentation for the follow-up of severe accidents

    International Nuclear Information System (INIS)

    Munoz Sanchez, A.; Nino Perote, R.

    2000-01-01

    During severe accidents, it is foreseeable that the instrumentation installed in a plant is subjected to conditions which are more hostile than those for which the instrumentation was designed and qualified. Moreover, new, specific instrumentation is required to monitor variables which have not been considered until now, and to control systems which lessen the consequences of severe accidents. Both existing instrumentation used to monitor critical functions in design basis accident conditions and additional instrumentation which provides the information necessary to control and mitigate the consequences of severe accidents, have to be designed to withstand such conditions, especially in terms of measurements range, functional characteristics and qualification to withstand pressure and temperature loads resulting from steam explosion, hydrogen combustion/explosion and high levels of radiation over long periods of time. (Author)

  10. TOOLS TO INCLUDE BLIND STUDENTS IN SCHOOL BUILDING PERFORMANCE ASSESSMENTS

    Directory of Open Access Journals (Sweden)

    Tania Pietzschke Abate

    2016-05-01

    Full Text Available This article discusses the design of data collection instruments that include the opinions of blind students, in accordance with the principles of Universal Design (UD. The aim of this study is to understand the importance of adapting data collection instruments for the inclusion of disabled persons in field research in Architecture and Design, among other fields. The data collection instruments developed were a play interview with a tactile map and a 3D survey with the use of tactile models. These instruments sought to assess the school environment experienced by blind students. The study involved students from the early years of a school for the blind who had not yet mastered the Braille system. The participation of these students was evaluated. A multidisciplinary team consisting of architects, designers, educators, and psychologists lent support to the study. The results showed that the data collection instruments adapted to blind students were successful in making the group of authors examine questions regarding UD. An analysis of the participatory phase showed that the limitations resulting from blindness determine the specificities in the adaptation and implementation process of the instruments in schools. Practical recommendations for future studies related to instruments in the UD thematic are presented. This approach is in line with the global trend of including disabled persons in society based on these users’ opinions concerning what was designed by architects and designers.

  11. Reactor instrumentation renewal of the TRIGA reactor Vienna, Austria

    International Nuclear Information System (INIS)

    Boeck, H.; Weiss, H.; Hood, W.E.; Hyde, W.K.

    1992-01-01

    The TRIGA Mark-II reactor at the Atominstitut in Vienna, Austria is replacing its twenty-four year old instrumentation system with a microprocessor based control system supplied by General Atomics. Ageing components, new governmental safety requirements and a need for state of the art instrumentation for training students has spurred the demand for new reactor instrumentation. In Austria a government appointed expert is assigned the responsibility of reviewing the proposed installation and verifying all safety aspects. After a positive review, final assembly and checkout of the instrumentation system may commence. The instrumentation system consists of three basic modules: the control system console, the data acquisition console and the NH-1000 wide range channel. Digital communications greatly reduce interwiring requirements. Hardwired safety channels are independent of computer control, thus, the instrumentation system in no way relies on any computer intervention for safety function. In addition, both the CSC and DAC computers are continuously monitored for proper operation via watchdog circuits which are capable of shutting down the reactor in the event of computer malfunction. Safety channels include two interlocked NMP-1000 multi-range linear channels for steady state mode, an NPP-1000 linear safety channel for pulse mode and a set of three independent fuel temperature monitoring channels. The microprocessor controlled wide range NM- 1000 digital neutron monitor (fission chamber based) functions as a startup/operational channel, and provides all power level related Interlocks. The Atominstitut TRIGA reactor is configured for four modes of operation: manual mode, automatic mode (servo control), pulsing mode and square wave mode. Control of the standard control rods is via stepping motor control rod drives, which offers the operator the choice of which control rods are operated by the servo system in automatic and square wave model. (author)

  12. Tamper and radiation resistant instrumentation for safeguarding special nuclear materials

    International Nuclear Information System (INIS)

    Parsons, B.B.; Wells, J.L.

    1977-01-01

    A tamper-resistant liquid level/accountability instrumentation system for safeguards use has been developed and tested. The tests demonstrate the accuracy of liquid level measurement using TDR (Time Domain Reflectometry) techniques and the accuracy of differential pressure and temperature measurements utilizing a custom designed liquid level sensor probe. The calibrated liquid level, differential pressure, and temperature data provide sufficient information to accurately determine volume, density, and specific gravity. Test solutions used include ordinary tap water, diluted nitric acid in varying concentrations, and diluted uranium trioxide also in varying concentrations. System operations and preliminary test results conducted at the General Electric Midwest Fuel Recovery Plant and the National Bureau of Standards, respectively, suggest that the system will provide the safeguards inspector with an additional tool for real-time independent verification of normal operations and special nuclear materials accountancy data for chemical reprocessing plants. This paper discusses the system design concepts, including a brief description of the tamper and radiation resistant features, the preliminary test results, and the significance of the work

  13. Analysis instruments for the performance of Advanced Practice Nursing.

    Science.gov (United States)

    Sevilla-Guerra, Sonia; Zabalegui, Adelaida

    2017-11-29

    Advanced Practice Nursing has been a reality in the international context for several decades and recently new nursing profiles have been developed in Spain as well that follow this model. The consolidation of these advanced practice roles has also led to of the creation of tools that attempt to define and evaluate their functions. This study aims to identify and explore the existing instruments that enable the domains of Advanced Practice Nursing to be defined. A review of existing international questionnaires and instruments was undertaken, including an analysis of the design process, the domains/dimensions defined, the main results and an exploration of clinimetric properties. Seven studies were analysed but not all proved to be valid, stable or reliable tools. One included tool was able to differentiate between the functions of the general nurse and the advanced practice nurse by the level of activities undertaken within the five domains described. These tools are necessary to evaluate the scope of advanced practice in new nursing roles that correspond to other international models of competencies and practice domains. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  14. The introduction of radiation monitor produced by several nuclear instrument factories

    International Nuclear Information System (INIS)

    Yu Liying

    2005-01-01

    The paper introduce some radiation monitor products of several nuclear instrument factories include Xi'an Nuclear Instrument Factory, MGP Instruments Inc, and Canberra Industries Inc. The introduction aspects include the range, configuration, and application of products. So, the paper is reference for the designer with responsibility for radiation monitoring system of new nuclear project. (authors)

  15. Operational and reliability experience with reactor instrumentation

    International Nuclear Information System (INIS)

    Dixon, F.; Gow, R.S.

    1978-01-01

    In the last 15 years the CEGB has experienced progressive plant development, integration and changes in operating regime through nine nuclear (gas-cooled reactor) power stations with corresponding instrumentation advances leading towards more refined centralized control. Operation and reliability experience with reactor instrumentation is reported in this paper with reference to the progressive changes related to the early magnox, late magnox and AGR periods. Data on instrumentation reliability in terms of reactor forced outages are presented and show that the instrumentation contributions to loss of generating plant availability are small. Reactor safety circuits, neutron flux and temperature measurements, gas analysis and vibration monitoring are discussed. In reviewing the reactor instrumentation the emphasis is on reporting recent experience, particularly on AGR equipment, but overall performance and changes to magnox equipment are included so that some appreciation can be obtained of instrumentation requirements with respect to plant lifetimes. (author)

  16. Chiropractic treatment including instrument-assisted manipulation for non-specific dizziness and neck pain in community-dwelling older people: a feasibility randomised sham-controlled trial.

    Science.gov (United States)

    Kendall, Julie C; French, Simon D; Hartvigsen, Jan; Azari, Michael F

    2018-01-01

    Dizziness in older people is a risk factor for falls. Neck pain is associated with dizziness and responds favourably to neck manipulation. However, it is unknown if chiropractic intervention including instrument-assisted manipulation of the neck in older people with neck pain can also improve dizziness. This parallel two-arm pilot trial was conducted in Melbourne, Australia over nine months (October 2015 to June 2016). Participants aged 65-85 years, with self-reported chronic neck pain and dizziness, were recruited from the general public through advertisements in local community newspapers and via Facebook. Participants were randomised using a permuted block method to one of two groups: 1) Activator II™-instrument-assisted cervical and thoracic spine manipulation plus a combination of: light massage; mobilisation; range of motion exercises; and home advice about the application of heat, or 2) Sham-Activator II™-instrument-assisted manipulation (set to zero impulse) plus gentle touch of cervical and thoracic spinal regions. Participants were blinded to group allocation. The interventions were delivered weekly for four weeks. Assessments were conducted one week pre- and post-intervention. Clinical outcomes were assessed blindly and included: dizziness (dizziness handicap inventory [DHI]); neck pain (neck disability index [NDI]); self-reported concerns of falling; mood; physical function; and treatment satisfaction. Feasibility outcomes included recruitment rates, compliance with intervention and outcome assessment, study location, success of blinding, costs and harms. Out of 162 enquiries, 24 participants were screened as eligible and randomised to either the chiropractic ( n  = 13) or sham ( n  = 11) intervention group. Compliance was satisfactory with only two participants lost to follow up; thus, post-intervention data for 12 chiropractic intervention and 10 sham intervention participants were analysed. Blinding was similar between groups. Mild harms

  17. Radon-daughter chamber instrumentation system reference manual

    International Nuclear Information System (INIS)

    Showalter, R.; Johnson, L.

    1985-01-01

    The radon-daughter chamber instrumentation system collects environmental data from the radon-daughter chamber. These data are then recorded on a Tandberg system tape cartridge and transmitted to the HP-1000 computer for processing. Generators which inject radon and condensation nuclei into the chamber are also included with the instrumentation system

  18. Instrumentation for PIXE and RBS

    International Nuclear Information System (INIS)

    2000-12-01

    The purpose of this document is to give an overview of instrumentation for PIXE and Rutherford backscattering analysis, including hardware and software needed to perform the analysis, including detectors, analyzers, data acquisition systems and data analysis software. It also provides some information on accelerators needed for these applications

  19. Cellular telephone-based radiation detection instrument

    Science.gov (United States)

    Craig, William W [Pittsburg, CA; Labov, Simon E [Berkeley, CA

    2011-06-14

    A network of radiation detection instruments, each having a small solid state radiation sensor module integrated into a cellular phone for providing radiation detection data and analysis directly to a user. The sensor module includes a solid-state crystal bonded to an ASIC readout providing a low cost, low power, light weight compact instrument to detect and measure radiation energies in the local ambient radiation field. In particular, the photon energy, time of event, and location of the detection instrument at the time of detection is recorded for real time transmission to a central data collection/analysis system. The collected data from the entire network of radiation detection instruments are combined by intelligent correlation/analysis algorithms which map the background radiation and detect, identify and track radiation anomalies in the region.

  20. Behavioral and neurobiological mechanisms of extinction in Pavlovian and instrumental learning.

    Science.gov (United States)

    Todd, Travis P; Vurbic, Drina; Bouton, Mark E

    2014-02-01

    This article reviews research on the behavioral and neural mechanisms of extinction as it is represented in both Pavlovian and instrumental learning. In Pavlovian extinction, repeated presentation of a signal without its reinforcer weakens behavior evoked by the signal; in instrumental extinction, repeated occurrence of a voluntary action without its reinforcer weakens the strength of the action. In either case, contemporary research at both the behavioral and neural levels of analysis has been guided by a set of extinction principles that were first generated by research conducted at the behavioral level. The review discusses these principles and illustrates how they have informed the study of both Pavlovian and instrumental extinction. It shows that behavioral and neurobiological research efforts have been tightly linked and that their results are readily integrated. Pavlovian and instrumental extinction are also controlled by compatible behavioral and neural processes. Since many behavioral effects observed in extinction can be multiply determined, we suggest that the current close connection between behavioral-level and neural-level analyses will need to continue. Copyright © 2013 Elsevier Inc. All rights reserved.

  1. Wavefront-Error Performance Characterization for the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM) Science Instruments

    Science.gov (United States)

    Aronstein, David L.; Smith, J. Scott; Zielinski, Thomas P.; Telfer, Randal; Tournois, Severine C.; Moore, Dustin B.; Fienup, James R.

    2016-01-01

    The science instruments (SIs) comprising the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM) were tested in three cryogenic-vacuum test campaigns in the NASA Goddard Space Flight Center (GSFC)'s Space Environment Simulator (SES). In this paper, we describe the results of optical wavefront-error performance characterization of the SIs. The wavefront error is determined using image-based wavefront sensing (also known as phase retrieval), and the primary data used by this process are focus sweeps, a series of images recorded by the instrument under test in its as-used configuration, in which the focal plane is systematically changed from one image to the next. High-precision determination of the wavefront error also requires several sources of secondary data, including 1) spectrum, apodization, and wavefront-error characterization of the optical ground-support equipment (OGSE) illumination module, called the OTE Simulator (OSIM), 2) plate scale measurements made using a Pseudo-Nonredundant Mask (PNRM), and 3) pupil geometry predictions as a function of SI and field point, which are complicated because of a tricontagon-shaped outer perimeter and small holes that appear in the exit pupil due to the way that different light sources are injected into the optical path by the OGSE. One set of wavefront-error tests, for the coronagraphic channel of the Near-Infrared Camera (NIRCam) Longwave instruments, was performed using data from transverse translation diversity sweeps instead of focus sweeps, in which a sub-aperture is translated andor rotated across the exit pupil of the system.Several optical-performance requirements that were verified during this ISIM-level testing are levied on the uncertainties of various wavefront-error-related quantities rather than on the wavefront errors themselves. This paper also describes the methodology, based on Monte Carlo simulations of the wavefront-sensing analysis of focus-sweep data, used to establish the

  2. Costs and Risks of Continuous Purges for Instruments

    Science.gov (United States)

    Secunda, M.; De Garcia, K. Montt

    2018-01-01

    As instruments are built, tested, and launched, they are exposed to environments that have various levels of cleanliness. Often, Scientists and Contamination Control Engineers specify a purge to mitigate the instrument's exposure to a non-clean environment, protect sensitive optics from a specific threat, such as water, or as insurance against things going wrong in a clean environment. The cost of the purge, in effort, dollars and risk, is often understated when the requirements are being established, and the need for purge is not clearly justifiable. This paper will more clearly define some of the costs and risks associated with the continuous purging of instruments during the course of building, testing and launching instruments.

  3. Vibration test report for in-chimney bracket and instrumented fuel assembly

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jeong Soo; Yoon, D. B.; Cho, Y. G.; Ahn, G. H.; Lee, J. H.; Park, J.H

    2000-10-01

    The vibration levels of in-chimney bracket structure which is installed in reactor chimney and instrumented fuel assembly(Type-B Bundle) are investigated under the steady state normal operating condition of the reactor. For this purpose, 4 acceleration data on the guide tube of the instrumented fuel assembly and in-chimney bracket structures subjected to fluid induced vibration are measured. For the analysis of the vibration data, vibration analysis program which can perform basic time and frequency domain analysis, is prepared, and its reliability is verified by comparing the analysis results with those of commercial analysis program(I-DEAS). In time domain analysis, maximum amplitudes, and RMS values of accelerations and displacements from the measured vibration signal, are obtained. The frequency components of the vibration data are analyzed by using the frequency domain analysis. These analysis results show that the levels of the measured vibrations are within the allowable level, and the low frequency component near 10 Hz is dominant in the vibration signal. For the evaluation of the structural integrity on the in-chimney bracket and related structures including the instrumented fuel assembly, the static analysis for ANSYS finite element model is carried out. These analysis results show that the maximum stresses are within the allowable stresses of the ASME code, and the maximum displacement of the top of the flow tube is within the displacement limit. Therefore any damage on the structural integrity is not expected when the irradiation test is performed using the in-chimney bracket.

  4. Vibration test report for in-chimney bracket and instrumented fuel assembly

    International Nuclear Information System (INIS)

    Ryu, Jeong Soo; Yoon, D. B.; Cho, Y. G.; Ahn, G. H.; Lee, J. H.; Park, J.H.

    2000-10-01

    The vibration levels of in-chimney bracket structure which is installed in reactor chimney and instrumented fuel assembly(Type-B Bundle) are investigated under the steady state normal operating condition of the reactor. For this purpose, 4 acceleration data on the guide tube of the instrumented fuel assembly and in-chimney bracket structures subjected to fluid induced vibration are measured. For the analysis of the vibration data, vibration analysis program which can perform basic time and frequency domain analysis, is prepared, and its reliability is verified by comparing the analysis results with those of commercial analysis program(I-DEAS). In time domain analysis, maximum amplitudes, and RMS values of accelerations and displacements from the measured vibration signal, are obtained. The frequency components of the vibration data are analyzed by using the frequency domain analysis. These analysis results show that the levels of the measured vibrations are within the allowable level, and the low frequency component near 10 Hz is dominant in the vibration signal. For the evaluation of the structural integrity on the in-chimney bracket and related structures including the instrumented fuel assembly, the static analysis for ANSYS finite element model is carried out. These analysis results show that the maximum stresses are within the allowable stresses of the ASME code, and the maximum displacement of the top of the flow tube is within the displacement limit. Therefore any damage on the structural integrity is not expected when the irradiation test is performed using the in-chimney bracket

  5. Utility Assessment of Specificity in Upward Feedback Instruments for Leadership Development

    National Research Council Canada - National Science Library

    Wardak, Theresa

    2003-01-01

    ...) and the other is the recently developed, non-proprietary Upward Feedback Instrument (2002). The Upward Feedback Instrument was designed to measure leadership behaviors at a more specific level...

  6. SGR-76 gamma radiation level indicator

    International Nuclear Information System (INIS)

    Chubinskij-Nadezhdin, I.V.

    1978-01-01

    The design of a gamma-radiation level indicator is described; the instrument is part of a mobile radiometric laboratory (MRL). The design of the instrument permits gamma-radiation dose rates recording at 0.2-200 R/hr, and signals on gamma-background levels. The instrument has two separate threshold levels of signalling actuation. The light signalling at the first level is precautionary, and the sound signalling at the second level indicates the necessity of taking a decision as to whether or not the MRL can remain in the gamma-radiation field. Halogenic counters operating in a current mode are used as detectors. The basic error in recording the dose rate amounts to +-25%. Overall dimensions of the instrument 150x280x100 mm; weight less than 2.5 kg

  7. Instrument Remote Control via the Astronomical Instrument Markup Language

    Science.gov (United States)

    Sall, Ken; Ames, Troy; Warsaw, Craig; Koons, Lisa; Shafer, Richard

    1998-01-01

    The Instrument Remote Control (IRC) project ongoing at NASA's Goddard Space Flight Center's (GSFC) Information Systems Center (ISC) supports NASA's mission by defining an adaptive intranet-based framework that provides robust interactive and distributed control and monitoring of remote instruments. An astronomical IRC architecture that combines the platform-independent processing capabilities of Java with the power of Extensible Markup Language (XML) to express hierarchical data in an equally platform-independent, as well as human readable manner, has been developed. This architecture is implemented using a variety of XML support tools and Application Programming Interfaces (API) written in Java. IRC will enable trusted astronomers from around the world to easily access infrared instruments (e.g., telescopes, cameras, and spectrometers) located in remote, inhospitable environments, such as the South Pole, a high Chilean mountaintop, or an airborne observatory aboard a Boeing 747. Using IRC's frameworks, an astronomer or other scientist can easily define the type of onboard instrument, control the instrument remotely, and return monitoring data all through the intranet. The Astronomical Instrument Markup Language (AIML) is the first implementation of the more general Instrument Markup Language (IML). The key aspects of our approach to instrument description and control applies to many domains, from medical instruments to machine assembly lines. The concepts behind AIML apply equally well to the description and control of instruments in general. IRC enables us to apply our techniques to several instruments, preferably from different observatories.

  8. Graduate studies in instrumentation at the University of Provence

    International Nuclear Information System (INIS)

    Carette, M.; Reynard, C.; Claire, N.; Deschaintres, J. L.; Felts, B.; Lyoussi, A.; Andre, J.; Bertin, D.

    2009-01-01

    The University of Provence instrumentation department offers a high level of graduate and post graduate engineering programs. Its mission is to form technician experts and engineers with a deep knowledge in their discipline: metrology, instrumentation, tests, Research and Development, automatism and industrial process control. The specialty of master on test facilities instrumentation has been developed in collaboration with the French Atomic Energy Commission (CEA) since 2004. This curriculum offers now a specialization in nuclear detection and nuclear instrumentation. More than 80% of the graduates formed by block-release training of master find a job within 6 months

  9. Instrument construction to evaluate factors associated to willingness towards organ donation

    Directory of Open Access Journals (Sweden)

    Héctor Neira-San Martín

    2018-01-01

    Full Text Available The object of this study was the construction and pilot study of an instrument for evaluating factors associated to individuals’ willingness towards organ donation. The Questionnaire about Knowledge, Attitudes and Beliefs consists of 22 items Likert type of self administration. It was answered by 244 adults, guardians of 10 schools from Concepcion, Chile, who belonged to the middle and lower socioeconomic levels. An Exploratory Factor Analysis was done under the method of Maximum Likelihood Estimation and Varimax rotation, which derived in five factors: a reliance on the process of donation and transplantation, b communication about organ donation within the family, c ideological beliefs on organ donation, d knowledge about organ donation and transplantation, and e autonomy on the choice of donation. The reliance was measured through the Alfa of Cronbach and the relationship among the factors, through r of Pearson. It was established that the instrument is pertinent and reliable and a new application is proposed, to be administered on a bigger sample that includes individuals from the higher socioeconomic levels.

  10. Instrument employing a charge flow transistor

    International Nuclear Information System (INIS)

    1981-01-01

    The invention concerns instruments employing charge-flow transistors that operate to sense a property in the surrounding environment. It is based on a particular sensor principle, thin-film conduction. The instruments described include a charge-flow transistor with semiconductor substrate, a source region, a drain region, a gate insulator, and a gapped electrode structure with a thin-film sensor material in the gap. The sensor material has an electrical conductance that is sensitive to a property of the ambient environment and has a surface conductance that differs substantially from its bulk conductance. The main object is to provide a low-cost instrument for early-warning fire-detection devices: in this case the property detected would be the products of combustion. Other properties that can be sensed include gases or vapors, free radicals, vapor electromagnetic radiation, subatomic particles, atomic or molecular beams, changes in ambient pressure or temperature, the chemical composition and the electrochemical potential of a solution. (U.K.)

  11. Instrument employing a charge flow transistor

    Energy Technology Data Exchange (ETDEWEB)

    1981-03-11

    The invention concerns instruments employing charge-flow transistors that operate to sense a property in the surrounding environment. It is based on a particular sensor principle, thin-film conduction. The instruments described include a charge-flow transistor with semiconductor substrate, a source region, a drain region, a gate insulator, and a gapped electrode structure with a thin-film sensor material in the gap. The sensor material has an electrical conductance that is sensitive to a property of the ambient environment and has a surface conductance that differs substantially from its bulk conductance. The main object is to provide a low-cost instrument for early-warning fire-detection devices: in this case the property detected would be the products of combustion. Other properties that can be sensed include gases or vapors, free radicals, vapor electromagnetic radiation, subatomic particles, atomic or molecular beams, changes in ambient pressure or temperature, the chemical composition and the electrochemical potential of a solution.

  12. DEVELOPING EVALUATION INSTRUMENT FOR MATHEMATICS EDUCATIONAL SOFTWARE

    Directory of Open Access Journals (Sweden)

    Wahyu Setyaningrum

    2012-02-01

    Full Text Available The rapid increase and availability of mathematics software, either for classroom or individual learning activities, presents a challenge for teachers. It has been argued that many products are limited in quality. Some of the more commonly used software products have been criticized for poor content, activities which fail to address some learning issues, poor graphics presentation, inadequate documentation, and other technical problems. The challenge for schools is to ensure that the educational software used in classrooms is appropriate and effective in supporting intended outcomes and goals. This paper aimed to develop instrument for evaluating mathematics educational software in order to help teachers in selecting the appropriate software. The instrument considers the notion of educational including content, teaching and learning skill, interaction, and feedback and error correction; and technical aspects of educational software including design, clarity, assessment and documentation, cost and hardware and software interdependence. The instrument use a checklist approach, the easier and effective methods in assessing the quality of educational software, thus the user needs to put tick in each criteria. The criteria in this instrument are adapted and extended from standard evaluation instrument in several references.   Keywords: mathematics educational software, educational aspect, technical aspect.

  13. Portable neutron and gamma-radiation instruments

    International Nuclear Information System (INIS)

    Murray, W.S.; Butterfield, K.B.

    1990-01-01

    This paper reports on the design and building of a smart neutron and gamma-radiation detection systems with embedded microprocessors programmed in the FORTH language. These portable instruments can be battery-powered and can provide many analysis functions not available in most radiation detectors. Local operation of the instruments is menu-driven through a graphics liquid crystal display and hex keypad; remote operation is through a serial communications link. While some instruments simply count particles, others determine the energy of the radiation as well as the intensity. The functions the authors have provided include absolute source-strength determination. Feynmann variance analysis, sequential-probability ratio test, and time-history recording

  14. Instrument calibration reduction through on-line monitoring in the USA. Annex IV

    International Nuclear Information System (INIS)

    Hashemian, H.M.

    2008-01-01

    Nuclear power plants are required to calibrate important instruments once every fuel cycle. This requirement dates back more than 30 years, when commercial nuclear power plants began to operate. Based on calibration data accumulated over this period, it has been determined that the calibration of some instruments, such as pressure transmitters, do not drift enough to warrant calibration as often as once every fuel cycle. This fact, combined with human resources limitations and reduced maintenance budgets, has provided the motivation for the nuclear industry to develop new technologies for identifying drifting instruments during plant operation. Implementing these technologies allows calibration efforts to be focused on the instruments that have drifted out of tolerance, as opposed to current practice, which calls for calibration verification of almost all instruments every fuel cycle. To date, an array of technologies, referred to collectively as 'on-line calibration monitoring', has been developed to meet this objective. These technologies are based on identifying outlier sensors using techniques that compare a particular sensor's output to a calculated estimate of the actual process the sensor is measuring. If on-line monitoring data are collected during plant startup and/or shutdown periods as well as normal operation, the on-line monitoring approach can help verify the calibration of instruments over their entire operating range. Although on-line calibration monitoring is applicable to most sensors and can cover an entire instrument channel, the main application of this approach in nuclear power plants is currently for pressure transmitters (including level and flow transmitters). (author)

  15. X-ray spectrometer instrumentation with a personal computer

    International Nuclear Information System (INIS)

    Skaarup, P.; Vogeley, E.

    1989-01-01

    A description is given of an instrumentation for control of an X-ray spectrometer used in solid state physics experiments. The instrumentation includes a personal computer (PC) and a European Computer Bus (ECB) interface system. Details are given of the operating software. (author)

  16. Overview of intercalibration of satellite instruments

    Science.gov (United States)

    Chander, G.; Hewison, T.J.; Fox, N.; Wu, X.; Xiong, X.; Blackwell, W.J.

    2013-01-01

    Inter-calibration of satellite instruments is critical for detection and quantification of changes in the Earth’s environment, weather forecasting, understanding climate processes, and monitoring climate and land cover change. These applications use data from many satellites; for the data to be inter-operable, the instruments must be cross-calibrated. To meet the stringent needs of such applications requires that instruments provide reliable, accurate, and consistent measurements over time. Robust techniques are required to ensure that observations from different instruments can be normalized to a common scale that the community agrees on. The long-term reliability of this process needs to be sustained in accordance with established reference standards and best practices. Furthermore, establishing physical meaning to the information through robust Système International d'unités (SI) traceable Calibration and Validation (Cal/Val) is essential to fully understand the parameters under observation. The processes of calibration, correction, stability monitoring, and quality assurance need to be underpinned and evidenced by comparison with “peer instruments” and, ideally, highly calibrated in-orbit reference instruments. Inter-calibration between instruments is a central pillar of the Cal/Val strategies of many national and international satellite remote sensing organizations. Inter-calibration techniques as outlined in this paper not only provide a practical means of identifying and correcting relative biases in radiometric calibration between instruments but also enable potential data gaps between measurement records in a critical time series to be bridged. Use of a robust set of internationally agreed upon and coordinated inter-calibration techniques will lead to significant improvement in the consistency between satellite instruments and facilitate accurate monitoring of the Earth’s climate at uncertainty levels needed to detect and attribute the mechanisms

  17. 26 CFR 1.1274-1 - Debt instruments to which section 1274 applies.

    Science.gov (United States)

    2010-04-01

    ... includes debt instruments and investment units, but does not include money, services, or the right to use... nonfunctional currency is treated as money rather than as property. (b) Exceptions—(1) Debt instrument with....1273-2. (3) Other exceptions to section 1274—(i) Holders of certain below-market instruments. Section...

  18. EPRTM Reactor neutron instrumentation

    International Nuclear Information System (INIS)

    Pfeiffer, Maxime; SALA, Stephanie

    2013-06-01

    The core safety during operation is linked, in particular, to the respect of criteria related to the heat generated in fuel rods and to the heat exchange between the rods and the coolant. This local power information is linked to the power distribution in the core. In order to evaluate the core power distribution, the EPR TM reactor relies on several types of neutron detectors: - ionization chambers located outside the vessel and used for protection and monitoring - a fixed in-core instrumentation based on Cobalt Self Powered Neutron Detectors used for protection and monitoring - a mobile reference in-core instrumentation based on Vanadium aero-balls This document provides a description of this instrumentation and its use in core protection, limitation, monitoring and control functions. In particular, a description of the detectors and the principles of their signal generation is supplied as well as the description of the treatments related to these detectors in the EPR TM reactor I and C systems (including periodical calibration). (authors)

  19. Payment Instrument Characteristics

    DEFF Research Database (Denmark)

    Holst, Jacques; Kjeldsen, Martin; Hedman, Jonas

    2015-01-01

    Over the last decade, we have witnessed payment innovations that fundamentally have changed the ways we pay. Payment innovations, such as mobile payments and on-line banking, include characteristics or features that are essential to understand if we want to know how and why payers choose among...... payment innovations. Using the Repertory Grid technique to explore 15 payers’ perception of six payment instruments, including coins, banknotes, debit cards, credit cards, mobile payments, and on-line banking, we identify 16 payment characteristics. The characteristics aggregate seventy-six unique...

  20. The Karen instruments for measuring quality of nursing care: construct validity and internal consistency.

    Science.gov (United States)

    Lindgren, Margareta; Andersson, Inger S

    2011-06-01

    Valid and reliable instruments for measuring the quality of care are needed for evaluation and improvement of nursing care. Previously developed and evaluated instruments, the Karen-patient and the Karen-personnel based on Donabedian's Structure-Process-Outcome triad (S-P-O triad) had promising content validity, discriminative power and internal consistency. The objective of this study was to further develop the instruments with regard to construct validity and internal consistency. This prospective study was carried out in medical and surgical wards at a hospital in Sweden. A total of 95 patients and 120 personnel were included. The instruments were tested for construct validity by performing factor analyses in two steps and for internal consistency using Cronbach's alpha coefficient. The first confirmatory factor analyses, with a pre-determined three-factor solution did not load well according to the S-P-O triad, but the second exploratory factor analysis with a six-factor solution appeared to be more coherent and the distribution of variables seemed to be logical. The reliability, i.e. internal consistency, was good in both factor analyses. The Karen-patient and the Karen-personnel instruments have achieved acceptable levels of construct validity. The internal consistency of the instruments is good. This indicates that the instruments may be suitable to use in clinical practice for measuring the quality of nursing care.

  1. Broad bandwidth frequency domain instrument for quantitative tissue optical spectroscopy

    International Nuclear Information System (INIS)

    Pham, Tuan H.; Coquoz, Olivier; Fishkin, Joshua B.; Anderson, Eric; Tromberg, Bruce J.

    2000-01-01

    Near-infrared (NIR) optical properties of turbid media, e.g., tissue, can be accurately quantified noninvasively using methods based on diffuse reflectance or transmittance, such as frequency domain photon migration (FDPM). Factors which govern the accuracy and sensitivity of FDPM-measured optical properties include instrument performance, the light propagation model, and fitting algorithms used to calculate optical properties from measured data. In this article, we characterize instrument, model, and fitting uncertaintics of an FDPM system designed for clinical use and investigate how each of these factors affects the quantification of NIR absorption (μ a ) and reduced scattering (μ s ' ) parameters in tissue phantoms. The instrument is based on a 500 MHz, multiwavelength platform that sweeps through 201 discrete frequencies in as little as 675 ms. Phase and amplitude of intensity modulated light launched into tissue, i.e., diffuse photon density waves (PDW), are measured with an accuracy of ±0.30 degree sign and ±3.5%, while phase and amplitude precision are ±0.025 degree sign and ±0.20%, respectively. At this level of instrument uncertainty, simultaneous fitting of frequency-dependent phase and amplitude nonlinear model functions derived from a photon diffusion approximation provides an accurate and robust strategy for determining optical properties from FDPM data, especially for media with high absorption. In an optical property range that is characteristic of most human tissues in the NIR (5x10 -3 a -2 mm -1 , 0.5 s ' -1 ), we theoretically and experimentally demonstrate that the multifrequency, simultaneous-fit approach allows μ a and μ s ' to be quantified with an accuracy of ±5% and ±3%, respectively. Although exceptionally high levels of precision can be obtained using this approach ( a and μ s ' . (c) 2000 American Institute of Physics

  2. Instrumentation, control and modellisation/simulation in waste water treatment plants; Instrumentacion, control y modelizacion/simulacion en plantas depuradoras de aguas residuales

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, E.; Martinez, J. L.; Llorente, V.

    2002-07-01

    Controlling waste water treatment plants presents numerous problems as a result of the complexity of the task involved in managing them. The different instruments used in monitoring and controlling the flow, dissolved oxygen, pH, cloudiness and other parameters involved in the treatment process at level 0 are listed and described. The control and regulation equipment comprising level 1 is operated by the process computers of level 2. The different types of instruments are studied in relation to monitoring and control and the analysis and management o the data supplied by the instrumentation, the control strategies, operational margins and applicable software. Several case studies of activated sludge treatment processes are included to facilitate comprehension. Finally, the simulation models are presented with a view to aiding understanding, management and prediction of the operation of waste water treatment plants, particularly in regard to the problems of bulking and/or foaming. (Author)

  3. Optical fibers and their instrumentation applications

    International Nuclear Information System (INIS)

    Boisde, Gilbert.

    1982-09-01

    The use of optical fibers in instrumentation requires a knowledge of their properties as ''photon carriers'' and ''sensors''. New instrumentation design implies a satisfactory evaluation of the entire measurement circuit, including the emitter, optical coupling, optical fiber with its physical, spectral and physico-chemical properties, the connector, receiver, signal amplifier and data processing system. An example, is provided of the development of a new technique in physico-chemical instrumentation: remote spectrophotometry. Three aspects are discussed: 1) industrial measurement in ''process control'' using the Telephot (R), 2) remote spectral measurement, 3) opical multiplexing. This is followed by a review of various optical fiber based instrumental techniques used in the fields of medicine (endoscopy, fluorothermy, laser surgery), solar energy industrial applications subject to electrical disturbances (position sensors, strain measurements), and in physico-chemical analysis (fluorescence, redox potentials) [fr

  4. Comparison of retreatment ability of full-sequence reciprocating instrumentation and 360° rotary instrumentation.

    Science.gov (United States)

    Capar, Ismail Davut; Gok, Tuba; Orhan, Ezgi

    2015-12-01

    The purpose of the present study was to investigate the amount of root canal filling material after root canal filling removal with 360° rotary instrumentation or reciprocating motion with the same file sequence. Root canals of the 36 mandibular premolars were shaped with ProTaper Universal instruments up to size F2 and filled with corresponding single gutta-percha cone and sealer. The teeth were assigned to two retreatment groups (n = 18): group 1 360° rotational motion and group 2 reciprocating motion of ATR Tecnika motors (1310° clockwise and 578° counterclockwise). Retreatment procedure was performed with ProTaper Universal retreatment files with a sequence of D1-3 and ProTaper Universal F3 instruments. Total time required to remove filling material were recorded. Remaining filling material was examined under stereomicroscope at ×8 magnification. The data were analysed statistically using the Mann-Whitney U test, and testing was performed at 95 % confidence level (p  0.05) in terms of remaining filling material. The total time required for retreatment was shorter in 360° rotational motion group compared to reciprocating motion group (p instruments with reciprocating motion of ATR motor and conventional rotary motion have similar efficacy in root canal filling removal.

  5. Power plant instrumentation for measurement of high-purity water quality

    International Nuclear Information System (INIS)

    Brown, J.

    1981-01-01

    Work undertaken by Ontario Hydro, Toronto, to determine levels of feedwater impurities, including corrosion products and condenser cooling water in leakage contaminants, is reviewed. Corrosion product measurement using a grab method gave some useful data but was found to be too labor-intensive. Continuous analysis of corrosion products, in conjunction with a valveless capillary sampler, is now being evaluated as a method. Ion chromatography appears to be a promising technique to determine anions in feedwater. Tests to adapt such an instrument for continuous analysis are planned

  6. Instrumentation

    International Nuclear Information System (INIS)

    Umminger, K.

    2008-01-01

    A proper measurement of the relevant single and two-phase flow parameters is the basis for the understanding of many complex thermal-hydraulic processes. Reliable instrumentation is therefore necessary for the interaction between analysis and experiment especially in the field of nuclear safety research where postulated accident scenarios have to be simulated in experimental facilities and predicted by complex computer code systems. The so-called conventional instrumentation for the measurement of e. g. pressures, temperatures, pressure differences and single phase flow velocities is still a solid basis for the investigation and interpretation of many phenomena and especially for the understanding of the overall system behavior. Measurement data from such instrumentation still serves in many cases as a database for thermal-hydraulic system codes. However some special instrumentation such as online concentration measurement for boric acid in the water phase or for non-condensibles in steam atmosphere as well as flow visualization techniques were further developed and successfully applied during the recent years. Concerning the modeling needs for advanced thermal-hydraulic codes, significant advances have been accomplished in the last few years in the local instrumentation technology for two-phase flow by the application of new sensor techniques, optical or beam methods and electronic technology. This paper will give insight into the current state of instrumentation technology for safety-related thermohydraulic experiments. Advantages and limitations of some measurement processes and systems will be indicated as well as trends and possibilities for further development. Aspects of instrumentation in operating reactors will also be mentioned.

  7. Radiation monitoring instrumentation for nuclear power plants

    International Nuclear Information System (INIS)

    Bharath Kumar, M.

    2013-01-01

    Measurement of nucleonic signals is required to control and operate the reactor in a safe and reliable manner. To achieve this, parameters like Neutron flux, other radiation fields, contamination levels, source strength, release thru stack etc. are required to be monitored and controlled. The above are required to be monitored throughout the life of the reactor whether it is operational or in shutdown condition. In addition such monitoring is also required during decommissioning phase of the reactor as needed. To measure these parameters a large number of instruments are used in Nuclear Power Plants (NPP) which includes sensors and electronics for detecting alpha, beta, gamma and neutron radiation with qualification to withstand harsh environment

  8. Tesla-VUPJT instruments suitable for application in water management

    International Nuclear Information System (INIS)

    Novakova, O.; Broj, K.; Fronka, O.; Kula, J.; Slezak, V.

    1987-01-01

    A comparison is made of new instruments by Tesla, Czechoslovakia, viz. the NA 6201 for low alpha and beta counting and the NRR 610 alpha-beta automatic gauge, with similar foreign made instruments. The factors are discussed which affect the overall detection efficiency and the background level. (B.S.). 4 tabs

  9. A review of instruments to measure interprofessional team-based primary care.

    Science.gov (United States)

    Shoemaker, Sarah J; Parchman, Michael L; Fuda, Kathleen Kerwin; Schaefer, Judith; Levin, Jessica; Hunt, Meaghan; Ricciardi, Richard

    2016-07-01

    Interprofessional team-based care is increasingly regarded as an important feature of delivery systems redesigned to provide more efficient and higher quality care, including primary care. Measurement of the functioning of such teams might enable improvement of team effectiveness and could facilitate research on team-based primary care. Our aims were to develop a conceptual framework of high-functioning primary care teams to identify and review instruments that measure the constructs identified in the framework, and to create a searchable, web-based atlas of such instruments (available at: http://primarycaremeasures.ahrq.gov/team-based-care/ ). Our conceptual framework was developed from existing frameworks, the teamwork literature, and expert input. The framework is based on an Input-Mediator-Output model and includes 12 constructs to which we mapped both instruments as a whole, and individual instrument items. Instruments were also reviewed for relevance to measuring team-based care, and characterized. Instruments were identified from peer-reviewed and grey literature, measure databases, and expert input. From nearly 200 instruments initially identified, we found 48 to be relevant to measuring team-based primary care. The majority of instruments were surveys (n = 44), and the remainder (n = 4) were observational checklists. Most instruments had been developed/tested in healthcare settings (n = 30) and addressed multiple constructs, most commonly communication (n = 42), heedful interrelating (n = 42), respectful interactions (n = 40), and shared explicit goals (n = 37). The majority of instruments had some reliability testing (n = 39) and over half included validity testing (n = 29). Currently available instruments offer promise to researchers and practitioners to assess teams' performance, but additional work is needed to adapt these instruments for primary care settings.

  10. Measuring Medical Housestaff Teamwork Performance Using Multiple Direct Observation Instruments: Comparing Apples and Apples.

    Science.gov (United States)

    Weingart, Saul N; Yaghi, Omar; Wetherell, Matthew; Sweeney, Megan

    2018-04-10

    To examine the composition and concordance of existing instruments used to assess medical teams' performance. A trained observer joined 20 internal medicine housestaff teams for morning work rounds at Tufts Medical Center, a 415-bed Boston teaching hospital, from October through December 2015. The observer rated each team's performance using 9 teamwork observation instruments that examined domains including team structure, leadership, situation monitoring, mutual support, and communication. Observations recorded on paper forms were stored electronically. Scores were normalized from 1 (low) to 5 (high) to account for different rating scales. Overall mean scores were calculated and graphed; weighted scores adjusted for the number of items in each teamwork domain. Teamwork scores were analyzed using t-tests, pair-wise correlations, and the Kruskal-Wallis statistic, and team performance was compared across instruments by domain. The 9 tools incorporated 5 major domains, with 5-35 items per instrument for a total of 161 items per observation session. In weighted and unweighted analyses, the overall teamwork performance score for a given team on a given day varied by instrument. While all of the tools identified the same low outlier, high performers on some instruments were low performers on others. Inconsistent scores for a given team across instruments persisted in domain-level analyses. There was substantial variation in the rating of individual teams assessed concurrently by a single observer using multiple instruments. Since existing teamwork observation tools do not yield concordant assessments, researchers should create better tools for measuring teamwork performance.

  11. Instrument failure monitoring in nuclear power systems

    International Nuclear Information System (INIS)

    Tylee, J.L.

    1982-01-01

    Methods of monitoring dynamic systems for instrument failures were developed and evaluated. In particular, application of these methods to nuclear power plant components is addressed. For a linear system, statistical tests on the innovations sequence of a Kalman filter driven by all system measurements provides a failure detection decision and identifies any failed sensor. This sequence (in an unfailed system) is zero-mean with calculable covariance; hence, any major deviation from these properties is assumed to be due to an instrument failure. Once a failure is identified, the failed instrument is replaced with an optimal estimate of the measured parameter. This failure accommodation is accomplished using optimally combined data from a bank of accommodation Kalman filters (one for each sensor), each driven by a single measurement. Using such a sensor replacement allows continued system operation under failed conditions and provides a system operator with information otherwise unavailable. To demonstrate monitor performance, a liner failure monitor was developed for the pressurizer in the Loss-of-Fluid Test (LOFT) reactor plant. LOFT is a small-scale pressurized water reactor (PWR) research facility located at the Idaho National Engineering Laboratory. A linear, third-order model of the pressurizer dynamics was developed from first principles and validated. Using data from the LOFT L6 test series, numerous actual and simulated water level, pressure, and temperature sensor failures were employed to illustrate monitor capabilities. Failure monitor design was applied to nonlinear dynamic systems by replacing all monitor linear Kalman filters with extended Kalman filters. A nonlinear failure monitor was derived for LOFT reactor instrumentation. A sixth-order reactor model, including descriptions of reactor kinetics, fuel rod heat transfer, and core coolant dynamics, was obtained and verified with test data

  12. Validation on groundwater flow model including sea level change. Modeling on groundwater flow in coastal granite area

    International Nuclear Information System (INIS)

    Hasegawa, Takuma; Miyakawa, Kimio

    2009-01-01

    It is important to verify the groundwater flow model that reproduces pressure head, water chemistry, and groundwater age. However, water chemistry and groundwater age are considered to be influenced by historical events. In this study, sea level change during glacial-interglacial cycle was taken into account for simulating salinity and groundwater age at coastal granite area. As a result of simulation, salinity movement could not catch up with sea level changes, and mixing zone was formed below the fresh-water zone. This mixing zone was observed in the field measurement, and the observed salinities were agreed with simulated results including sea level change. The simulated residence time including sea level change is one-tenth of steady state. The reason is that the saline water was washed out during regression and modern sea-water was infiltrated during transgression. As mentioned before, considering sea level change are important to reproduce salinity and helium age at coastal area. (author)

  13. Radiological Instrumentation Assessment for King County Wastewater Treatment Division

    International Nuclear Information System (INIS)

    Strom, Daniel J.; McConn, Ronald J.; Brodzinski, Ronald L.

    2005-01-01

    The King County Wastewater Treatment Division (WTD) have concern about the aftermath of a radiological dispersion event (RDE) leading to the introduction of significant quantities of radioactive material into its combined sanitary and storm sewer system. Radioactive material could come from the use of a radiological dispersion device (RDD). RDDs include 'dirty bombs' that are not nuclear detonations but are explosives designed to spread radioactive material. Radioactive material also could come from deliberate introduction or dispersion of radioactive material into the environment, including waterways and water supply systems. Volume 2 of PNNL-15163 assesses the radiological instrumentation needs for detection of radiological or nuclear terrorism, in support of decisions to treat contaminated wastewater or to bypass the West Point Treatment Plant (WPTP), and in support of radiation protection of the workforce, the public, and the infrastructure of the WPTP. Fixed radiation detection instrumentation should be deployed in a defense-in-depth system that provides (1) early warning of significant radioactive material on the way to the WPTP, including identification of the radionuclide(s) and estimates of the soluble concentrations, with a floating detector located in the wet well at the Interbay Pump Station and telemetered via the internet to all authorized locations; (2) monitoring at strategic locations within the plant, including (2a) the pipe beyond the hydraulic ram in the bar screen room; (2b) above the collection funnels in the fine grit facility; (2c) in the sampling tank in the raw sewage pump room; and (2d) downstream of the concentration facilities that produce 6% blended and concentrated biosolids. Engineering challenges exist for these applications. It is necessary to deploy both ultra-sensitive detectors to provide early warning and identification and detectors capable of functioning in high-dose rate environments that are likely under some scenarios

  14. Hair-zinc levels determination in Algerian psoriatics using Instrumental Neutron Activation Analysis (INAA)

    International Nuclear Information System (INIS)

    Mansouri, A.; Hamidatou Alghem, L.; Beladel, B.; Mokhtari, O.E.K.; Bendaas, A.; Benamar, M.E.A.

    2013-01-01

    Psoriasis is a multifactorial skin disease with an unknown etiology. Zinc has a positive impact on psoriasis. The aim of this study is to determine hair-zinc concentration in Algerian psoriatics. 58 psoriatics and 31 normal controls of both genders were selected. Hair zinc levels were determined using Instrumental Neutron Activation Analysis technique (INAA). Student's t-test and One-Way ANOVA were applied. The average zinc concentration for controls and patients were 152±53 μg/g and 167±52 μg/g respectively. They are not significantly different (p>0.05). Zn concentration for males and females controls and patients were 171±27 μg/g, 151±37 μg/g and 145±59 μg/g, 178±58 μg/g respectively. However, for females we have observed a significant difference (p<0.05). - Highlights: ► Psoriasis is a multifactorial skin disease with an unknown etiology. ► About 2–5% of global population in the world suffers from psoriasis. ► The aim of this study is to determine hair-zinc concentration in Algerian psoriatics. ► The average zinc concentration for controls and patients were 152±53 μg/g and 167±52 μg/g respectively.

  15. Selection of fusion levels in idiopathic adolescent scoliosis treated by Harrington-DDT instrumentation

    DEFF Research Database (Denmark)

    Andersen, G R; Andersen, M O; Christensen, S B

    1995-01-01

    Clinical records and radiographs of 106 patients treated by Harrington-dorsal transverse traction (DDT) instrumentation for idiopathic adolescent thoracolumbar scoliosis were reviewed. Our strategy was to fuse from one vertebra above the measured curve to two vertebrae below the curve, but to avoid...

  16. Gender and Instrument Associations, Stereotypes, and Stratification: A Literature Review

    Science.gov (United States)

    Wych, Gina M. F.

    2012-01-01

    This literature review examines and synthesizes 30 years of research into the relationship between gender and musical instruments. Specifically, the review focuses on how this relationship affects instrument selection by grade school students entering a school music program. Topics include the gender typing of musical instruments, instrument…

  17. An introduction to biomedical instrumentation

    CERN Document Server

    Dewhurst, D J

    1976-01-01

    An Introduction to Biomedical Instrumentation presents a course of study and applications covering the basic principles of medical and biological instrumentation, as well as the typical features of its design and construction. The book aims to aid not only the cognitive domain of the readers, but also their psychomotor domain as well. Aside from the seminar topics provided, which are divided into 27 chapters, the book complements these topics with practical applications of the discussions. Figures and mathematical formulas are also given. Major topics discussed include the construction, handli

  18. Measurement noise of a point autofocus surface topography instrument

    DEFF Research Database (Denmark)

    Feng, Xiaobing; Quagliotti, Danilo; Maculotti, Giacomo

    Optical instruments for areal topography measurement can be especially sensitive to noise when scanning is required. Such noise has different sources, including those internally generated and external sources from the environment.......Optical instruments for areal topography measurement can be especially sensitive to noise when scanning is required. Such noise has different sources, including those internally generated and external sources from the environment....

  19. Toward biotechnology in space: High-throughput instruments for in situ biological research beyond Earth.

    Science.gov (United States)

    Karouia, Fathi; Peyvan, Kianoosh; Pohorille, Andrew

    2017-11-15

    Space biotechnology is a nascent field aimed at applying tools of modern biology to advance our goals in space exploration. These advances rely on our ability to exploit in situ high throughput techniques for amplification and sequencing DNA, and measuring levels of RNA transcripts, proteins and metabolites in a cell. These techniques, collectively known as "omics" techniques have already revolutionized terrestrial biology. A number of on-going efforts are aimed at developing instruments to carry out "omics" research in space, in particular on board the International Space Station and small satellites. For space applications these instruments require substantial and creative reengineering that includes automation, miniaturization and ensuring that the device is resistant to conditions in space and works independently of the direction of the gravity vector. Different paths taken to meet these requirements for different "omics" instruments are the subjects of this review. The advantages and disadvantages of these instruments and technological solutions and their level of readiness for deployment in space are discussed. Considering that effects of space environments on terrestrial organisms appear to be global, it is argued that high throughput instruments are essential to advance (1) biomedical and physiological studies to control and reduce space-related stressors on living systems, (2) application of biology to life support and in situ resource utilization, (3) planetary protection, and (4) basic research about the limits on life in space. It is also argued that carrying out measurements in situ provides considerable advantages over the traditional space biology paradigm that relies on post-flight data analysis. Published by Elsevier Inc.

  20. Planning instruments to control urban growth

    DEFF Research Database (Denmark)

    Jørgensen, Gertrud; Nielsen, Thomas Alexander Sick

    2010-01-01

    It is challenging to plan and control urban development in peri-urban areas. But if no planning is done, the result will often be unsustainable, including widespread, dispersed and uncoordinated urban growth. Spatial planning based on zoning remains the most important planning instrument and its...... success depend on regional coordination. Incentive based instruments may contrbute to growth management, but only few examples are available and their effects on urban growth patterns yet to be seen....

  1. Social interactions and college enrollment: A combined school fixed effects/instrumental variables approach.

    Science.gov (United States)

    Fletcher, Jason M

    2015-07-01

    This paper provides some of the first evidence of peer effects in college enrollment decisions. There are several empirical challenges in assessing the influences of peers in this context, including the endogeneity of high school, shared group-level unobservables, and identifying policy-relevant parameters of social interactions models. This paper addresses these issues by using an instrumental variables/fixed effects approach that compares students in the same school but different grade-levels who are thus exposed to different sets of classmates. In particular, plausibly exogenous variation in peers' parents' college expectations are used as an instrument for peers' college choices. Preferred specifications indicate that increasing a student's exposure to college-going peers by ten percentage points is predicted to raise the student's probability of enrolling in college by 4 percentage points. This effect is roughly half the magnitude of growing up in a household with married parents (vs. an unmarried household). Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Applying neural networks to optimize instrumentation performance

    Energy Technology Data Exchange (ETDEWEB)

    Start, S.E.; Peters, G.G.

    1995-06-01

    Well calibrated instrumentation is essential in providing meaningful information about the status of a plant. Signals from plant instrumentation frequently have inherent non-linearities, may be affected by environmental conditions and can therefore cause calibration difficulties for the people who maintain them. Two neural network approaches are described in this paper for improving the accuracy of a non-linear, temperature sensitive level probe ised in Expermental Breeder Reactor II (EBR-II) that was difficult to calibrate.

  3. Applying neural networks to optimize instrumentation performance

    International Nuclear Information System (INIS)

    Start, S.E.; Peters, G.G.

    1995-01-01

    Well calibrated instrumentation is essential in providing meaningful information about the status of a plant. Signals from plant instrumentation frequently have inherent non-linearities, may be affected by environmental conditions and can therefore cause calibration difficulties for the people who maintain them. Two neural network approaches are described in this paper for improving the accuracy of a non-linear, temperature sensitive level probe ised in Expermental Breeder Reactor II (EBR-II) that was difficult to calibrate

  4. Management of broken instrument by file bypass technique

    Directory of Open Access Journals (Sweden)

    Sultana Parveen

    2017-02-01

    Full Text Available Different devices and techniques have been developed to retrieve fractured instruments during the endodontic procedures. This case report describes the management of a broken instrument, which was accidentally broken during cleaning and shaping of the root canal in right 2nd molar tooth. A # 25 stainless steel K-file was separated in mesiobuccal canal of the treated tooth. At first, a radiograph was taken to confirm the level of separation of the instrument. The instrument was found to be separated at the apical 3rd of the mesial canal and then file bypass technique was performed. Calcium hydroxide dressing was given for 7 days followed by obturation with guttapercha cone and zinc oxide eugenol sealer in lateral condensation technique. It can be concluded that bypass technique can be considered as simple and effective technique for the management of broken instrument into the root canal.

  5. Instruments for measuring mental health recovery: a systematic review.

    Science.gov (United States)

    Sklar, Marisa; Groessl, Erik J; O'Connell, Maria; Davidson, Larry; Aarons, Gregory A

    2013-12-01

    Persons in recovery, providers, and policymakers alike are advocating for recovery-oriented mental health care, with the promotion of recovery becoming a prominent feature of mental health policy in the United States and internationally. One step toward creating a recovery-oriented system of care is to use recovery-oriented outcome measures. Numerous instruments have been developed to assess progress towards mental health recovery. This review identifies instruments of mental health recovery and evaluates the appropriateness of their use including their psychometric properties, ease of administration, and service-user involvement in their development. A literature search using the Medline and Psych-INFO databases was conducted, identifying 21 instruments for potential inclusion in this review, of which thirteen met inclusion criteria. Results suggest only three instruments (25%) have had their psychometric properties assessed in three or more unique samples of participants. Ease of administration varied between instruments, and for the majority of instruments, development included service user involvement. This review updates and expands previous reviews of instruments to assess mental health recovery. As mental health care continues to transform to a recovery-oriented model of service delivery, this review may facilitate selection of appropriate assessments of mental health recovery for systems to use in evaluating and improving the care they provide. © 2013.

  6. Balances instruments, manufacturers, history

    CERN Document Server

    Robens, Erich; Kiefer, Susanne

    2014-01-01

    The book deals mainly with direct mass determination by means of a conventional balances. It covers the history of the balance from the beginnings in Egypt earlier than 3000 BC to recent developments. All balance types are described with emphasis on scientific balances. Methods of indirect mass determination, which are applied to very light objects like molecules and the basic particles of matter and celestial bodies, are included.  As additional guidance, today’s manufacturers are listed and the profile of important companies is reviewed. Several hundred photographs, reproductions and drawings show instruments and their uses. This book includes commercial weighing instruments for merchandise and raw materials in workshops as well as symbolic weighing in the ancient Egyptian’s ceremony of ‘Weighing of the Heart’, the Greek fate balance, the Roman  Justitia, Juno Moneta and Middle Ages scenes of the Last Judgement with Jesus or St. Michael and of modern balances. The photographs are selected from the...

  7. Instrumental interaction

    OpenAIRE

    Luciani , Annie

    2007-01-01

    International audience; The expression instrumental interaction as been introduced by Claude Cadoz to identify a human-object interaction during which a human manipulates a physical object - an instrument - in order to perform a manual task. Classical examples of instrumental interaction are all the professional manual tasks: playing violin, cutting fabrics by hand, moulding a paste, etc.... Instrumental interaction differs from other types of interaction (called symbolic or iconic interactio...

  8. Subsidence monitoring with geotechnical instruments in the Mexicali Valley, Baja California, Mexico

    Science.gov (United States)

    Glowacka, E.; Sarychikhina, O.; Márquez Ramírez, V. H.; Robles, B.; Nava, F. A.; Farfán, F.; García Arthur, M. A.

    2015-11-01

    The Mexicali Valley (northwestern Mexico), situated in the southern part of the San Andreas fault system, is an area with high tectonic deformation, recent volcanism, and active seismicity. Since 1973, fluid extraction, from the 1500-3000 m depth range, at the Cerro Prieto Geothermal Field (CPGF), has influenced deformation in the Mexicali Valley area, accelerating the subsidence and causing slip along the traces of tectonic faults that limit the subsidence area. Detailed field mapping done since 1989 (González et al., 1998; Glowacka et al., 2005; Suárez-Vidal et al., 2008) in the vicinity of the CPGF shows that many subsidence induced fractures, fissures, collapse features, small grabens, and fresh scarps are related to the known tectonic faults. Subsidence and fault rupture are causing damage to infrastructure, such as roads, railroad tracks, irrigation channels, and agricultural fields. Since 1996, geotechnical instruments installed by CICESE (Centro de Investigación Ciéntifica y de Educación Superior de Ensenada, B.C.) have operated in the Mexicali Valley, for continuous recording of deformation phenomena. Instruments are installed over or very close to the affected faults. To date, the network includes four crackmeters and eight tiltmeters; all instruments have sampling intervals in the 1 to 20 min range. Instrumental records typically show continuous creep, episodic slip events related mainly to the subsidence process, and coseismic slip discontinuities (Glowacka et al., 1999, 2005, 2010; Sarychikhina et al., 2015). The area has also been monitored by levelling surveys every few years and, since the 1990's by studies based on DInSAR data (Carnec and Fabriol, 1999; Hansen, 2001; Sarychikhina et al., 2011). In this work we use data from levelling, DInSAR, and geotechnical instruments records to compare the subsidence caused by anthropogenic activity and/or seismicity with slip recorded by geotechnical instruments, in an attempt to obtain more information

  9. Subsidence monitoring with geotechnical instruments in the Mexicali Valley, Baja California, Mexico

    Directory of Open Access Journals (Sweden)

    E. Glowacka

    2015-11-01

    Full Text Available The Mexicali Valley (northwestern Mexico, situated in the southern part of the San Andreas fault system, is an area with high tectonic deformation, recent volcanism, and active seismicity. Since 1973, fluid extraction, from the 1500–3000 m depth range, at the Cerro Prieto Geothermal Field (CPGF, has influenced deformation in the Mexicali Valley area, accelerating the subsidence and causing slip along the traces of tectonic faults that limit the subsidence area. Detailed field mapping done since 1989 (González et al., 1998; Glowacka et al., 2005; Suárez-Vidal et al., 2008 in the vicinity of the CPGF shows that many subsidence induced fractures, fissures, collapse features, small grabens, and fresh scarps are related to the known tectonic faults. Subsidence and fault rupture are causing damage to infrastructure, such as roads, railroad tracks, irrigation channels, and agricultural fields. Since 1996, geotechnical instruments installed by CICESE (Centro de Investigación Ciéntifica y de Educación Superior de Ensenada, B.C. have operated in the Mexicali Valley, for continuous recording of deformation phenomena. Instruments are installed over or very close to the affected faults. To date, the network includes four crackmeters and eight tiltmeters; all instruments have sampling intervals in the 1 to 20 min range. Instrumental records typically show continuous creep, episodic slip events related mainly to the subsidence process, and coseismic slip discontinuities (Glowacka et al., 1999, 2005, 2010; Sarychikhina et al., 2015. The area has also been monitored by levelling surveys every few years and, since the 1990's by studies based on DInSAR data (Carnec and Fabriol, 1999; Hansen, 2001; Sarychikhina et al., 2011. In this work we use data from levelling, DInSAR, and geotechnical instruments records to compare the subsidence caused by anthropogenic activity and/or seismicity with slip recorded by geotechnical instruments, in an attempt to obtain

  10. OBSERVATIONS OF BINARY STARS WITH THE DIFFERENTIAL SPECKLE SURVEY INSTRUMENT. I. INSTRUMENT DESCRIPTION AND FIRST RESULTS

    International Nuclear Information System (INIS)

    Horch, Elliott P.; Veillette, Daniel R.; Shah, Sagar C.; O'Rielly, Grant V.; Baena Galle, Roberto; Van Altena, William F.

    2009-01-01

    First results of a new speckle imaging system, the Differential Speckle Survey Instrument, are reported. The instrument is designed to take speckle data in two filters simultaneously with two independent CCD imagers. This feature results in three advantages over other speckle cameras: (1) twice as many frames can be obtained in the same observation time which can increase the signal-to-noise ratio for astrometric measurements, (2) component colors can be derived from a single observation, and (3) the two colors give substantial leverage over atmospheric dispersion, allowing for subdiffraction-limited separations to be measured reliably. Fifty-four observations are reported from the first use of the instrument at the Wisconsin-Indiana-Yale-NOAO 3.5 m Telescope 9 The WIYN Observatory is a joint facility of the University of Wisconsin-Madison, Indiana University, Yale University, and the National Optical Astronomy Observatories. in 2008 September, including seven components resolved for the first time. These observations are used to judge the basic capabilities of the instrument.

  11. Double-theodolite measurement system used in the image calibration of space photographic instrument

    Institute of Scientific and Technical Information of China (English)

    LI Yan; QIAO Yan-feng; SU Wan-xin; LIU Ze-xun

    2005-01-01

    The purpose of characterizing the image of space photographic instrument is to gain the space included angles from three coordinate axes in the three-dimensional coordinate of the image and the directionality of the three axes of coordinate in the frame of axes of the instrument. The two reference frames will keep in the same direction finally by adjusting according to space angles. This problem was solved by a new high-precision measurement system composed of a double-theodolite and a set of communication system. In the survey system, two TDA5005 total stations from Leica Company will be selected as the double-theodolite and the interdependence of both coordinate systems can be achieved by moving the stations only at one time. Therefore, this measurement system provides a highly efficient and high-precision surveying method to the image calibration of the space photographic instrument. According to the experiment, its measuring accuracy can reach arc-second level.

  12. Instrumentation development

    International Nuclear Information System (INIS)

    Ubbes, W.F.; Yow, J.L. Jr.

    1988-01-01

    Instrumentation is developed for the Civilian Radioactive Waste Management Program to meet several different (and sometimes conflicting) objectives. This paper addresses instrumentation development for data needs that are related either directly or indirectly to a repository site, but does not touch on instrumentation for work with waste forms or other materials. Consequently, this implies a relatively large scale for the measurements, and an in situ setting for instrument performance. In this context, instruments are needed for site characterization to define phenomena, develop models, and obtain parameter values, and for later design and performance confirmation testing in the constructed repository. The former set of applications is more immediate, and is driven by the needs of program design and performance assessment activities. A host of general technical and nontechnical issues have arisen to challenge instrumentation development. Instruments can be classed into geomechanical, geohydrologic, or other specialty categories, but these issues cut across artificial classifications. These issues are outlined. Despite this imposing list of issues, several case histories are cited to evaluate progress in the area

  13. A Review of Level 2 Parent-Report Instruments Used to Screen Children Aged 1.5-5 for Autism: A Meta-Analytic Update

    Science.gov (United States)

    Hampton, Justin; Strand, Paul S.

    2015-01-01

    The present study utilized meta-analytic procedures to estimate the diagnostic validity of instruments used to screen young children, ages 1.5-5 years, for autism. Five scales met inclusion criteria, and data from 18 studies contributed the meta-analysis. Results revealed that 4 of 5 scales met criteria for "good" validity, including two…

  14. Instrument accuracy in reactor vessel inventory tracking systems

    International Nuclear Information System (INIS)

    Anderson, J.L.; Anderson, R.L.; Morelock, T.C.; Hauang, T.L.; Phillips, L.E.

    1986-01-01

    Instrumentation needs for detection of inadequate core cooling. Studies of the Three Mile Island accident identified the need for additional instrumentation to detect inadequate core cooling (ICC) in nuclear power plants. Industry studies by plant owners and reactor vendors supported the conclusion that improvements were needed to help operators diagnose the approach to or existence of ICC as well as to provide more complete information for operator control of safety injection flow to minimize the consequences of such an accident. In 1980, the US Nuclear Regulatory Commission (NRC) required further studies by the industry and described ICC instrumentation design requirements that included human factors and environmental considerations. On December 10, 1982, NRC issued to Babcock and Wilcox (B and W) licensees orders for Modification of License and transmitted to pressurized water reactor licensees Generic Letter 82-28 to inform them of the revised NRC requirements. The instrumentation requirements include upgraded subcooling margin monitors (SMM), upgraded core exit thermocouples (CET), and installation of a reactor coolant inventory tracking system. NRC Regulatory Guide 1.97, which covers accident monitoring instrumentation, was revised (Rev. 3) to be consistent with the requirements of item II.F.2 of NUREG-0737

  15. Experimenting with Brass Musical Instruments.

    Science.gov (United States)

    LoPresto, Michael C.

    2003-01-01

    Describes experiments to address the properties of brass musical instruments that can be used to demonstrate sound in any level physics course. The experiments demonstrate in a quantitative fashion the effects of the mouthpiece and bell on the frequencies of sound waves and thus the musical pitches produced. (Author/NB)

  16. Virtual Sensor Test Instrumentation

    Science.gov (United States)

    Wang, Roy

    2011-01-01

    Virtual Sensor Test Instrumentation is based on the concept of smart sensor technology for testing with intelligence needed to perform sell-diagnosis of health, and to participate in a hierarchy of health determination at sensor, process, and system levels. A virtual sensor test instrumentation consists of five elements: (1) a common sensor interface, (2) microprocessor, (3) wireless interface, (4) signal conditioning and ADC/DAC (analog-to-digital conversion/ digital-to-analog conversion), and (5) onboard EEPROM (electrically erasable programmable read-only memory) for metadata storage and executable software to create powerful, scalable, reconfigurable, and reliable embedded and distributed test instruments. In order to maximize the efficient data conversion through the smart sensor node, plug-and-play functionality is required to interface with traditional sensors to enhance their identity and capabilities for data processing and communications. Virtual sensor test instrumentation can be accessible wirelessly via a Network Capable Application Processor (NCAP) or a Smart Transducer Interlace Module (STIM) that may be managed under real-time rule engines for mission-critical applications. The transducer senses the physical quantity being measured and converts it into an electrical signal. The signal is fed to an A/D converter, and is ready for use by the processor to execute functional transformation based on the sensor characteristics stored in a Transducer Electronic Data Sheet (TEDS). Virtual sensor test instrumentation is built upon an open-system architecture with standardized protocol modules/stacks to interface with industry standards and commonly used software. One major benefit for deploying the virtual sensor test instrumentation is the ability, through a plug-and-play common interface, to convert raw sensor data in either analog or digital form, to an IEEE 1451 standard-based smart sensor, which has instructions to program sensors for a wide variety of

  17. [Research on medical instrument information integration technology based on IHE PCD].

    Science.gov (United States)

    Zheng, Jianli; Liao, Yun; Yang, Yongyong

    2014-06-01

    Integrating medical instruments with medical information systems becomes more and more important in healthcare industry. To make medical instruments without standard communication interface possess the capability of interoperating and sharing information with medical information systems, we developed a medical instrument integration gateway based on Integrating the Healthcare Enterprise Patient Care Device (IHE PCD) integration profiles in this research. The core component is an integration engine which is implemented according to integration profiles and Health Level Seven (HL7) messages defined in IHE PCD. Working with instrument specific Javascripts, the engine transforms medical instrument data into HL7 ORU message. This research enables medical instruments to interoperate and exchange medical data with information systems in a standardized way, and is valuable for medical instrument integration, especially for traditional instruments.

  18. HTGR Measurements and Instrumentation Systems

    International Nuclear Information System (INIS)

    Ball, Sydney J.; Holcomb, David Eugene; Cetiner, Mustafa Sacit

    2012-01-01

    This report provides an integrated overview of measurements and instrumentation for near-term future high-temperature gas-cooled reactors (HTGRs). Instrumentation technology has undergone revolutionary improvements since the last HTGR was constructed in the United States. This report briefly describes the measurement and communications needs of HTGRs for normal operations, maintenance and inspection, fuel fabrication, and accident response. The report includes a description of modern communications technologies and also provides a potential instrumentation communications architecture designed for deployment at an HTGR. A principal focus for the report is describing new and emerging measurement technologies with high potential to improve operations, maintenance, and accident response for the next generation of HTGRs, known as modular HTGRs, which are designed with passive safety features. Special focus is devoted toward describing the failure modes of the measurement technologies and assessing the technology maturity.

  19. Impact of instrument response variations on health physics measurements

    International Nuclear Information System (INIS)

    Armantrout, G.A.

    1984-10-01

    Uncertainties in estimating the potential health impact of a given radiation exposure include instrument measurement error in determining exposure and difficulty in relating this exposure to an effective dose value. Instrument error can be due to design or manufacturing deficiencies, limitations of the sensing element used, and calibration and maintenance of the instrument. This paper evaluates the errors which can be introduced by design deficiencies and limitations of the sensing element for a wide variety of commonly used survey instruments. The results indicate little difference among sensing element choice for general survey work, with variations among specific instrument designs being the major factor. Ion chamber instruments tend to be the best for all around use, while scintillator-based units should not be used where accurate measurements are required. The need to properly calibrate and maintain an instrument appears to be the most important factor in instrument accuracy. 8 references, 6 tables

  20. High-level waste tank farm set point document

    International Nuclear Information System (INIS)

    Anthony, J.A. III.

    1995-01-01

    Setpoints for nuclear safety-related instrumentation are required for actions determined by the design authorization basis. Minimum requirements need to be established for assuring that setpoints are established and held within specified limits. This document establishes the controlling methodology for changing setpoints of all classifications. The instrumentation under consideration involve the transfer, storage, and volume reduction of radioactive liquid waste in the F- and H-Area High-Level Radioactive Waste Tank Farms. The setpoint document will encompass the PROCESS AREA listed in the Safety Analysis Report (SAR) (DPSTSA-200-10 Sup 18) which includes the diversion box HDB-8 facility. In addition to the PROCESS AREAS listed in the SAR, Building 299-H and the Effluent Transfer Facility (ETF) are also included in the scope

  1. High-level waste tank farm set point document

    Energy Technology Data Exchange (ETDEWEB)

    Anthony, J.A. III

    1995-01-15

    Setpoints for nuclear safety-related instrumentation are required for actions determined by the design authorization basis. Minimum requirements need to be established for assuring that setpoints are established and held within specified limits. This document establishes the controlling methodology for changing setpoints of all classifications. The instrumentation under consideration involve the transfer, storage, and volume reduction of radioactive liquid waste in the F- and H-Area High-Level Radioactive Waste Tank Farms. The setpoint document will encompass the PROCESS AREA listed in the Safety Analysis Report (SAR) (DPSTSA-200-10 Sup 18) which includes the diversion box HDB-8 facility. In addition to the PROCESS AREAS listed in the SAR, Building 299-H and the Effluent Transfer Facility (ETF) are also included in the scope.

  2. Proceedings of a workshop on methods for neutron scattering instrumentation design

    International Nuclear Information System (INIS)

    Hjelm, R.P.

    1997-09-01

    The future of neutron and x-ray scattering instrument development and international cooperation was the focus of the workshop. The international gathering of about 50 participants representing 15 national facilities, universities and corporations featured oral presentations, posters, discussions and demonstrations. Participants looked at a number of issues concerning neutron scattering instruments and the tools used in instrument design. Objectives included: (1) determining the needs of the neutron scattering community in instrument design computer code and information sharing to aid future instrument development, (2) providing for a means of training scientists in neutron scattering and neutron instrument techniques, and (3) facilitating the involvement of other scientists in determining the characteristics of new instruments that meet future scientific objectives, and (4) fostering international cooperation in meeting these needs. The scope of the meeting included: (1) a review of x-ray scattering instrument design tools, (2) a look at the present status of neutron scattering instrument design tools and models of neutron optical elements, and (3) discussions of the present and future needs of the neutron scattering community. Selected papers were abstracted separately for inclusion to the Energy Science and Technology Database

  3. Proceedings of a workshop on methods for neutron scattering instrumentation design

    Energy Technology Data Exchange (ETDEWEB)

    Hjelm, R.P. [ed.] [Los Alamos National Lab., NM (United States)

    1997-09-01

    The future of neutron and x-ray scattering instrument development and international cooperation was the focus of the workshop. The international gathering of about 50 participants representing 15 national facilities, universities and corporations featured oral presentations, posters, discussions and demonstrations. Participants looked at a number of issues concerning neutron scattering instruments and the tools used in instrument design. Objectives included: (1) determining the needs of the neutron scattering community in instrument design computer code and information sharing to aid future instrument development, (2) providing for a means of training scientists in neutron scattering and neutron instrument techniques, and (3) facilitating the involvement of other scientists in determining the characteristics of new instruments that meet future scientific objectives, and (4) fostering international cooperation in meeting these needs. The scope of the meeting included: (1) a review of x-ray scattering instrument design tools, (2) a look at the present status of neutron scattering instrument design tools and models of neutron optical elements, and (3) discussions of the present and future needs of the neutron scattering community. Selected papers were abstracted separately for inclusion to the Energy Science and Technology Database.

  4. The cross-cultural equivalence of participation instruments: a systematic review.

    Science.gov (United States)

    Stevelink, S A M; van Brakel, W H

    2013-07-01

    Concepts such as health-related quality of life, disability and participation may differ across cultures. Consequently, when assessing such a concept using a measure developed elsewhere, it is important to test its cultural equivalence. Previous research suggested a lack of cultural equivalence testing in several areas of measurement. This paper reviews the process of cross-cultural equivalence testing of instruments to measure participation in society. An existing cultural equivalence framework was adapted and used to assess participation instruments on five categories of equivalence: conceptual, item, semantic, measurement and operational equivalence. For each category, several aspects were rated, resulting in an overall category rating of 'minimal/none', 'partial' or 'extensive'. The best possible overall study rating was five 'extensive' ratings. Articles were included if the instruments focussed explicitly on measuring 'participation' and were theoretically grounded in the ICIDH(-2) or ICF. Cross-validation articles were only included if it concerned an adaptation of an instrument developed in a high or middle-income country to a low-income country or vice versa. Eight cross-cultural validation studies were included in which five participation instruments were tested (Impact on Participation and Autonomy, London Handicap Scale, Perceived Impact and Problem Profile, Craig Handicap Assessment Reporting Technique, Participation Scale). Of these eight studies, only three received at least two 'extensive' ratings for the different categories of equivalence. The majority of the cultural equivalence ratings given were 'partial' and 'minimal/none'. The majority of the 'none/minimal' ratings were given for item and measurement equivalence. The cross-cultural equivalence testing of the participation instruments included leaves much to be desired. A detailed checklist is proposed for designing a cross-validation study. Once a study has been conducted, the checklist can

  5. The use of ultrasonic instrumentation in liquid/liquid extraction plant

    International Nuclear Information System (INIS)

    Asher, R.C.; Bradshaw, L.; Tolchard, A.C.

    1984-01-01

    Ultrasonic instruments can be used to determine many of the parameters of interest in a liquid/liquid extraction plant, eg liquid levels, the position of interfaces between immiscible liquids and the concentration of solutions. The determinations can often be made non-invasively. A number of instruments developed for a liquid/liquid extraction plant used for nuclear fuel reprocessing is described. These instruments have a wider application in liquid/liquid extraction plant in general. (author)

  6. Examining the evidence for a recent acceleration in the rate of sea-level rise using combined instrumental and proxy data, North Carolina, USA

    Science.gov (United States)

    Kemp, A.; Horton, B. P.

    2007-12-01

    Whilst accelerated rates of relative sea-level (RSL) rise are potentially one of the most devastating impacts of future climate change, our understanding of decadal scale changes in sea-level is poor. This paper seeks to address this knowledge gap by combining tide gauge and high-precision geological reconstructions of relative sea-level of sufficient resolution and duration to detect any recent acceleration in the rate of sea-level rise. We offer a high resolution relative sea-level history for the last ~2000 years from the Albemarle - Pamlico Estuarine System in North Carolina. Contemporary foraminifera were collected from five back barrier marshes to create a regional scale modern training set. The use of multiple marshes from a region increases the ecological and environmental diversity included within the training set and reduces the probability of a no modern analogue outcome. To merge the five spatially distinct sites and to relate each to local tide levels we used the VDatum transformation tool. This method relates all samples to a common orthometric datum (NAVD88) and reduces error. We developed an accurate and precise transfer function to reconstruct former sea levels based upon the modern observable relationship between foraminifera and elevation with respect to the tidal frame. We applied the transfer function to salt-marsh core(s) from Sand Point (Roanoke Island), North Carolina to produce a late Holocene RSL record. An age-depth model was produced from composite chronologies of 210Pb, 14C and pollen chrono-horizons. We validated our approach by comparing geological based reconstructions and instrumental tide gauge records. Our records show that in the last ~2000 years sea level has risen at a background rate of ~1.1mm/yr. There is evidence for two recent accelerations in the rate of sea-level rise during the late 19th and 20th centuries to a current rate of ~4mm/yr.

  7. Vision though afocal instruments: generalized magnification and eye-instrument interaction

    Science.gov (United States)

    Harris, William F.; Evans, Tanya

    2018-04-01

    In Gaussian optics all observers experience the same magnification, the instrument's angular magnification, when viewing distant objects though a telescope or other afocal instruments. However, analysis in linear optics shows that this is not necessarily so in the presence of astigmatism. Because astigmatism may distort and rotate images it is appropriate to work with generalized angular magnification represented by a 2 × 2 matrix. An expression is derived for the generalized magnification for an arbitrary eye looking through an arbitrary afocal instrument. With afocal instruments containing astigmatic refracting elements not all eyes experience the same generalized magnification; there is interaction between eye and instrument. Eye-instrument interaction may change as the instrument is rotated about its longitudinal axis, there being no interaction in particular orientations. A simple numerical example is given. For sake of completeness, expressions for generalized magnification are also presented in the case of instruments that are not afocal and objects that are not distant.

  8. An Inexpensive, Open-Source USB Arduino Data Acquisition Device for Chemical Instrumentation.

    Science.gov (United States)

    Grinias, James P; Whitfield, Jason T; Guetschow, Erik D; Kennedy, Robert T

    2016-07-12

    Many research and teaching labs rely on USB data acquisition devices to collect voltage signals from instrumentation. However, these devices can be cost-prohibitive (especially when large numbers are needed for teaching labs) and require software to be developed for operation. In this article, we describe the development and use of an open-source USB data acquisition device (with 16-bit acquisition resolution) built using simple electronic components and an Arduino Uno that costs under $50. Additionally, open-source software written in Python is included so that data can be acquired using nearly any PC or Mac computer with a simple USB connection. Use of the device was demonstrated for a sophomore-level analytical experiment using GC and a CE-UV separation on an instrument used for research purposes.

  9. 18 CFR 367.2450 - Account 245, Derivative instrument liabilities-Hedges

    Science.gov (United States)

    2010-04-01

    ..., Derivative instrument liabilities—Hedges (a) This account must include the change in the fair value of... service company must record the change in the fair value of a derivative instrument liability related to a... change in the fair value of a derivative instrument liability related to a fair value hedge in this...

  10. 12 CFR 956.6 - Use of hedging instruments.

    Science.gov (United States)

    2010-01-01

    ... counterparty for over-the-counter derivative contracts shall include: (i) A requirement that market value... reasonable estimate of the market value of the over-the-counter derivative contract at termination (standard.... Derivative instruments that do not qualify as hedging instruments pursuant to GAAP may be used only if a non...

  11. A critical appraisal of instruments to measure outcomes of interprofessional education.

    Science.gov (United States)

    Oates, Matthew; Davidson, Megan

    2015-04-01

    Interprofessional education (IPE) is believed to prepare health professional graduates for successful collaborative practice. A range of instruments have been developed to measure the outcomes of IPE. An understanding of the psychometric properties of these instruments is important if they are to be used to measure the effectiveness of IPE. This review set out to identify instruments available to measure outcomes of IPE and collaborative practice in pre-qualification health professional students and to critically appraise the psychometric properties of validity, responsiveness and reliability against contemporary standards for instrument design. Instruments were selected from a pool of extant instruments and subjected to critical appraisal to determine whether they satisfied inclusion criteria. The qualitative and psychometric attributes of the included instruments were appraised using a checklist developed for this review. Nine instruments were critically appraised, including the widely adopted Readiness for Interprofessional Learning Scale (RIPLS) and the Interdisciplinary Education Perception Scale (IEPS). Validity evidence for instruments was predominantly based on test content and internal structure. Ceiling effects and lack of scale width contribute to the inability of some instruments to detect change in variables of interest. Limited reliability data were reported for two instruments. Scale development and scoring protocols were generally reported by instrument developers, but the inconsistent application of scoring protocols for some instruments was apparent. A number of instruments have been developed to measure outcomes of IPE in pre-qualification health professional students. Based on reported validity evidence and reliability data, the psychometric integrity of these instruments is limited. The theoretical test construction paradigm on which instruments have been developed may be contributing to the failure of some instruments to detect change in

  12. Cost effectiveness of rural development programme instruments in Denmark

    DEFF Research Database (Denmark)

    Jensen, J Dejgaard; Jakobsen, L; Madsen, B

    2011-01-01

    The objective of this study is to investigate the cost-effectiveness of selected instruments of the Danish Rural Development Programme 2007-2013, which constitutes the Danish implementation of the EU Rural Development Programme under Pillar Two of the Common Agricultural Policy. The Programme aims...... to support sustainable economic growth and income diversification in rural areas (and in particular in economically vulnerable areas). The study combines different datasets and simulation models at farm level (register data, Farm Accountancy Data, farm sector model, run-off models, etc.), municipality level...... (micro-based “National Accounts” for municipalities, municipality economic model) and national level (national economic model), which enables analysis at a fairly detailed geographical level and hence to evaluate the spatially distributed effects of the considered policy instruments, while at the same...

  13. Performance Evaluation Factors: Designing an Instrument for National Health Network in Iran

    Directory of Open Access Journals (Sweden)

    Sassan Ghorbani-Kalkhajeh

    2016-04-01

    Full Text Available As a systematic process for gathering and analyzing data, performance evaluation could be used as a valid method to highlight levels of success and to identify strength and weakness of ongoing programs. The aim of the present study was to develop an instrument for evaluating rural health centers in Iran. Based on related literature and experts’ views, eight crucial fields of performance evaluation, and a questionnaire including 100 items were formed. The participants of the study were 525 people having health related jobs in rural or urban health centers. Reliability and validity requirements were checked; exploratory and confirmatory factor analyses were used. Factor analysis identified 11 components which embraced 60 items. Components were named as planning, control, coordination, structure, setting and facilities, education, customers’ satisfaction, staff’s job satisfaction, disease surveillance, mother-child care, and effectiveness which are presented as a model for performance evaluation. The obtained instrument embraces all required factors suggested by experts and literature hence it can be used as an evaluation instrument in both rural and urban health centers.

  14. Operator/instrumentation interactions during the Three Mile Island incident

    International Nuclear Information System (INIS)

    Cummings, G.E.

    1979-10-01

    A discussion is presented of the operator/instrumentation interactions which had an effect on the course of the incident at the Three Mile Island-2 Nuclear Power Plant. A brief review of the sequence of occurrences at TMI-2 over the first 16 hours of the incident is given with particular emphasis on operator/instrumentation interactions. A breakdown of the six major items that seemed to have contributed to the characteristics of the incident is then given and also an outline of some of the currently proposed operator/instrumentation improvements. The six major items involve water level indication in the reactor, electromatic relief valve operation, auxiliary feed-water flow indication, containment isolation, extended range instrumentation, and computer readout

  15. Hand and ultrasonic instrumentation for orthograde root canal treatment of permanent teeth

    Directory of Open Access Journals (Sweden)

    Vinícius Pedrazzi

    2010-06-01

    Full Text Available Root canal treatment is a frequently performed dental procedure and is carried out on teeth in which irreversible pulpitis has led to necrosis of the dental pulp. Removal of the necrotic tissue remnants and cleaning and shaping of the root canal are important phases of root canal treatment. Treatment options include the use of hand and rotary instruments and methods using ultrasonic or sonic equipment. OBJECTIVES: The objectives of this systematic review of randomized controlled trials were to determine the relative clinical effectiveness of hand instrumentation versus ultrasonic instrumentation alone or in conjunction with hand instrumentation for orthograde root canal treatment of permanent teeth. MATERIAL AND METHODS: The search strategy retrieved 226 references from the Cochrane Oral Health Group Trials Register (7, the Cochrane Central Register of Controlled Trials (CENTRAL (12, MEDLINE (192, EMBASE (8 and LILACS (7. No language restriction was applied. The last electronic search was conducted on December 13th, 2007. Screening of eligible studies was conducted in duplicate and independently. RESULTS: Results were to be expressed as fixed-effect or random-effects models using mean differences for continuous outcomes and risk ratios for dichotomous outcomes with 95% confdence intervals. Heterogeneity was to be investigated including both clinical and methodological factors. No eligible randomized controlled trials were identifed. CONCLUSIONS: This review illustrates the current lack of published or ongoing randomized controlled trials and the unavailability of high-level evidence based on clinically relevant outcomes referring to the effectiveness of ultrasonic instrumentation used alone or as an adjunct to hand instrumentation for orthograde root canal treatment. In the absence of reliable research-based evidence, clinicians should base their decisions on clinical experience, individual circumstances and in conjunction with patients

  16. IASI instrument: technical description and measured performances

    Science.gov (United States)

    Hébert, Ph.; Blumstein, D.; Buil, C.; Carlier, T.; Chalon, G.; Astruc, P.; Clauss, A.; Siméoni, D.; Tournier, B.

    2017-11-01

    IASI is an infrared atmospheric sounder. It will provide meteorologist and scientific community with atmospheric spectra. The IASI system includes 3 instruments that will be mounted on the Metop satellite series, a data processing software integrated in the EPS (EUMETSAT Polar System) ground segment and a technical expertise centre implemented in CNES Toulouse. The instrument is composed of a Fourier transform spectrometer and an associated infrared imager. The optical configuration is based on a Michelson interferometer and the interferograms are processed by an on-board digital processing subsystem, which performs the inverse Fourier transforms and the radiometric calibration. The infrared imager co-registers the IASI soundings with AVHRR imager (AVHRR is another instrument on the Metop satellite). The presentation will focus on the architectures of the instrument, the description of the implemented technologies and the measured performance of the first flight model. CNES is leading the IASI program in association with EUMETSAT. The instrument Prime is ALCATEL SPACE.

  17. Extension of the activities of the Israeli SSDL down to the low level region

    International Nuclear Information System (INIS)

    Kuszpet, M.

    1981-11-01

    The report describes the actions taken at the Israeli Secondary Standard Dosimetry Laboratories SSDL in order to carry out low level calibrations. The reference instrument (a NE balloon chamber) was calibrated against the therapy level secondary standard, using a PTW 30 cm 3 chamber as a link instrument. A check of the stability of the reference instrument over an eight months period, showed a drift of 1.5+-1.5%. Thus, routine instrument's calibration should be carried out to keep the accuracy below acceptable limits. An analysis of the uncertainties introduced by the transfer of the calibration shows that the accuracy can be kept within acceptable limits (less than +-2% at a 92% confidence level). Calibrations are carried out using three different series: 50 mrad/h, 500 mrad/h and 5000 mrad/h. Before routine calibrations were carried out, preliminary measurements were made to check the proper operation of the set-up. These measurements included beam homogeneity, reproducibility of distance, reproducibility and energy dependence of the transmission monitor chamber, HVL determinations, etc. An estimation of the uncertainties introduced by the calibration process led to a figure of +-4% at the 92% confidence level, which is considered adequate for routine calibrations of field instruments

  18. Instrument-related Skin Disorders in Musicians.

    Science.gov (United States)

    Patruno, Cataldo; Napolitano, Maddalena; La Bella, Serena; Ayala, Fabio; Balato, Nicola; Cantelli, Mariateresa; Balato, Anna

    2016-01-01

    Among artists, musicians may suffer from occupational skin problems; notwithstanding, these conditions have been rarely reviewed. The characteristics of individual performer and the type of instrument will determine the kind of disease. Moreover, the hours that the musician spent to advance artistic skill may influence the severity. The frequency and risk factors of instrument-related skin disorders in musicians from southern Italy were analyzed. An observational study was conducted in 628 musicians. A questionnaire including questions related to age, sex, instrument played, musical activity, previous or current skin disorders, and impact of skin symptoms on music making was submitted. Of 628 musicians, 199 (31.7%) reported suffering from at least 1 skin disease. Cutaneous diseases likely directly correlated with the use of the musical instrument were found in 129 (20.5%) of the 628 subjects. In particular, different patterns of irritant contact dermatitis were found. Skin conditions may be a significant problem in professional instrumentalists. They are mainly related to musical activity. Preventive measures should be established.

  19. Field instrumentation for hydrofracturing stress measurements

    International Nuclear Information System (INIS)

    Bjarnason, Bjarni; Torikka, Arne.

    1989-08-01

    A recently developed system for rock stress measurements by the hydraulic fracturing method is documented in detail. The new equipment is intended for measurement in vertical or nearvertical boreholes, down to a maximum depth of 1000 m. The minimum borehole, diameter required is 56 mm. Downhole instrumentation comprises a straddle packer assembly for borehole fracturing, equipment for determination of fracture orientations and a pressure transducer. The downhole tools are operated by means of a multihose system, containing high pressure hydraulic tubings, signal cable and carrying wire into one hose unit. The surface components of the equipment include a system for generation and control of water pressures up to approximately 75 MPa, an hydraulically operated drum for the multihose and a data acquisition system. All surface instrumentation is permanently mounted on a truck, which also serves as power source for the instrumentation. In addition to the description of instrumentation, the theoretical fundament and the testing procedures associated with the hydraulic fracturing method are briefly outlined

  20. Advances in Miniaturized Instruments for Genomics

    Directory of Open Access Journals (Sweden)

    Cihun-Siyong Alex Gong

    2014-01-01

    Full Text Available In recent years, a lot of demonstrations of the miniaturized instruments were reported for genomic applications. They provided the advantages of miniaturization, automation, sensitivity, and specificity for the development of point-of-care diagnostics. The aim of this paper is to report on recent developments on miniaturized instruments for genomic applications. Based on the mature development of microfabrication, microfluidic systems have been demonstrated for various genomic detections. Since one of the objectives of miniaturized instruments is for the development of point-of-care device, impedimetric detection is found to be a promising technique for this purpose. An in-depth discussion of the impedimetric circuits and systems will be included to provide total consideration of the miniaturized instruments and their potential application towards real-time portable imaging in the “-omics” era. The current excellent demonstrations suggest a solid foundation for the development of practical and widespread point-of-care genomic diagnostic devices.

  1. Charge separation at nanoscale interfaces: energy-level alignment including two-quasiparticle interactions.

    Science.gov (United States)

    Li, Huashan; Lin, Zhibin; Lusk, Mark T; Wu, Zhigang

    2014-10-21

    The universal and fundamental criteria for charge separation at interfaces involving nanoscale materials are investigated. In addition to the single-quasiparticle excitation, all the two-quasiparticle effects including exciton binding, Coulomb stabilization, and exciton transfer are considered, which play critical roles on nanoscale interfaces for optoelectronic applications. We propose a scheme allowing adding these two-quasiparticle interactions on top of the single-quasiparticle energy level alignment for determining and illuminating charge separation at nanoscale interfaces. Employing the many-body perturbation theory based on Green's functions, we quantitatively demonstrate that neglecting or simplifying these crucial two-quasiparticle interactions using less accurate methods is likely to predict qualitatively incorrect charge separation behaviors at nanoscale interfaces where quantum confinement dominates.

  2. Radiation-hardened micro-electronics for nuclear instrumentation

    International Nuclear Information System (INIS)

    Van Uffelen, M.

    2007-01-01

    The successful development and deployment of future fission and thermonuclear fusion reactors depends to a large extent on the advances of different enabling technologies. Not only the materials need to be custom engineered but also the instrumentation, the electronics and the communication equipment need to support operation in this harsh environment, with expected radiation levels during maintenance up to several MGy. Indeed, there are yet no commercially available electronic devices available off-the-shelf which demonstrated a satisfying operation at these extremely high radiation levels. The main goal of this task is to identify commercially available radiation tolerant technologies, and to design dedicated and integrated electronic circuits, using radiation hardening techniques, both at the topological and architectural level. Within a stepwise approach, we first design circuits with discrete components and look for an equivalent integrated technology. This will enable us to develop innovative instrumentation and communication tools for the next generation of nuclear reactors, where both radiation hardening and miniaturization play a dominant role

  3. Instrumentation and test gear circuits manual

    CERN Document Server

    Marston, R M

    2013-01-01

    Instrumentation and Test Gear Circuits Manual provides diagrams, graphs, tables, and discussions of several types of practical circuits. The practical circuits covered in this book include attenuators, bridges, scope trace doublers, timebases, and digital frequency meters. Chapter 1 discusses the basic instrumentation and test gear principles. Chapter 2 deals with the design of passive attenuators, and Chapter 3 with passive and active filter circuits. The subsequent chapters tackle 'bridge' circuits, analogue and digital metering techniques and circuitry, signal and waveform generation, and p

  4. EARLY READING ASSESSMENT INSTRUMENTS: ABILITIES AND PROCESSES INVOLVED

    Directory of Open Access Journals (Sweden)

    Ana Cláudia de Souza

    2017-04-01

    Full Text Available This study investigates the following early reading assessment instruments: “Bateria de Recepção e Produção da Linguagem Verbal” (SCLIAR-CABRAL, 2003a and “Teste de Competência de Leitura de Palavras e Pseudopalavras” (SEABRA; CAPOVILLA, 2010. The main research goal is to analyze in each one of these reading assessment instruments some of the multiple cognitive processes and basic low-level abilities involved in reading. In this sense, decoding, word recognition, lexical access, syntactic and textual processing, and comprehension are the cognitive processes taken into account. With regard to the basic reading abilities, accuracy and fluency (rhythm, prosody and speed are considered. The results indicate that each one of the analyzed reading assessment instruments assesses different aspects of the reading processes and abilities, mainly through off-line measures. ScliarCabral’s assessment battery allows the researcher or the teacher to evaluate the following processes: perception of the grapheme opposition in minimal pairs of words and in sentences, difficulties in sentence processing, skills in decoding the graphemic-phonemic relationship, and textual comprehension. In its turn, the reading assessment instrument proposed by Seabra e Capovilla allows one to evaluate student’s reading development level, by classifying the kind of processing as logographic, alphabetic or orthographic.

  5. Large Instrument Development for Radio Astronomy

    Science.gov (United States)

    Fisher, J. Richard; Warnick, Karl F.; Jeffs, Brian D.; Norrod, Roger D.; Lockman, Felix J.; Cordes, James M.; Giovanelli, Riccardo

    2009-03-01

    This white paper offers cautionary observations about the planning and development of new, large radio astronomy instruments. Complexity is a strong cost driver so every effort should be made to assign differing science requirements to different instruments and probably different sites. The appeal of shared resources is generally not realized in practice and can often be counterproductive. Instrument optimization is much more difficult with longer lists of requirements, and the development process is longer and less efficient. More complex instruments are necessarily further behind the technology state of the art because of longer development times. Including technology R&D in the construction phase of projects is a growing trend that leads to higher risks, cost overruns, schedule delays, and project de-scoping. There are no technology breakthroughs just over the horizon that will suddenly bring down the cost of collecting area. Advances come largely through careful attention to detail in the adoption of new technology provided by industry and the commercial market. Radio astronomy instrumentation has a very bright future, but a vigorous long-term R&D program not tied directly to specific projects needs to be restored, fostered, and preserved.

  6. A comparison of high-frequency noise levels on Cascadia Initiative ocean-bottom seismometers

    Science.gov (United States)

    Hilmo, R.; Wilcock, W. S. D.; Roland, E. C.; Bodin, P.; Connolly, J.

    2017-12-01

    The Cascadia Initiative (CI) included a four-year deployment of 70 ocean bottom seismometers (OBSs) on the Cascadia subduction zone and the Juan de Fuca plate for the purposes of characterizing seismicity and imaging the Earth's interior. The Cascadia subduction zone megathrust exhibits very low rates of seismicity relative to most other subduction zones, and there is great motivation to understand deformation on the megathrust because of its potential to produce a catastrophic M9 earthquake. An understanding of earthquake detectability of the CI network, based on knowledge of noise levels, could contribute to the interpretation of earthquake catalogs derived from the experiment and aid in the design of future networks. This project is aimed at estimating these thresholds of local earthquake detectability and how they change across the array both geographically and temporally. We characterize background noise levels recorded from 0.1 to 20 Hz with an emphasis on the frequency band used to detect local seismicity ( 3-15 Hz) to understand how noise levels depend on instrument design and environmental parameters including seafloor depth, season and oceanographic conditions. Our initial analysis of 3 weeks of vertical channel data in September, January, and May 2012-2013 shows that noise increase significantly moving from the continental shelf to deeper water. Noise levels at a given depth vary with instrument type but further analysis is required to determine whether this reflects variations in instrumental noise and ground coupling noise or errors in the scaling of the instrument response. There is also a strong seasonality in recorded noise levels at some frequencies, with winter noise levels exceeding spring and fall noise levels by up to 10 decibels in both the microseism band and in the fin whale calling band (15-20 Hz). In contrast, the seasonal noise level in the local seismicity band for a given instrument type and location shows smaller noise variation

  7. Validated finite element analyses of WaveOne Endodontic Instruments: a comparison between M-Wire and NiTi alloys.

    Science.gov (United States)

    Bonessio, N; Pereira, E S J; Lomiento, G; Arias, A; Bahia, M G A; Buono, V T L; Peters, O A

    2015-05-01

    To validate torsional analysis, based on finite elements, of WaveOne instruments against in vitro tests and to model the effects of different nickel-titanium (NiTi) materials. WaveOne reciprocating instruments (Small, Primary and Large, n = 8 each, M-Wire) were tested under torsion according to standard ISO 3630-1. Torsional profiles including torque and angle at fracture were determined. Test conditions were reproduced through Finite Element Analysis (FEA) simulations based on micro-CT scans at 10-μm resolution; results were compared to experimental data using analysis of variance and two-sided one sample t-tests. The same simulation was performed on virtual instruments with identical geometry and load condition, based on M-Wire or conventional NiTi alloy. Torsional profiles from FEA simulations were in significant agreement with the in vitro results. Therefore, the models developed in this study were accurate and able to provide reliable simulation of the torsional performance. Stock NiTi files under torsional tests had up to 44.9%, 44.9% and 44.1% less flexibility than virtual M-Wire files at small deflections for Small, Primary and Large instruments, respectively. As deflection levels increased, the differences in flexibility between the two sets of simulated instruments decreased until fracture. Stock NiTi instruments had a torsional fracture resistance up to 10.3%, 8.0% and 7.4% lower than the M-Wire instruments, for the Small, Primary and Large file, respectively. M-Wire instruments benefitted primarily through higher material flexibility while still at low deflection levels, compared with conventional NiTi alloy. At fracture, the instruments did not take complete advantage of the enhanced fractural resistance of the M-Wire material, which determines only limited improvements of the torsional performance. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  8. Introduction to instrumentation and measurements

    CERN Document Server

    Northrop, Robert B

    2014-01-01

    Weighing in on the growth of innovative technologies, the adoption of new standards, and the lack of educational development as it relates to current and emerging applications, the third edition of Introduction to Instrumentation and Measurements uses the authors' 40 years of teaching experience to expound on the theory, science, and art of modern instrumentation and measurements (I&M). What's New in This Edition: This edition includes material on modern integrated circuit (IC) and photonic sensors, micro-electro-mechanical (MEM) and nano-electro-mechanical (NEM) sensors, chemical and radiation sensors, signal conditioning, noise, data interfaces, and basic digital signal processing (DSP), and upgrades every chapter with the latest advancements. It contains new material on the designs of micro-electro-mechanical (MEMS) sensors, adds two new chapters on wireless instrumentation and microsensors, and incorporates extensive biomedical examples and problems. Containing 13 chapters, this third edition: Describ...

  9. A pilot study to measure levels of selected elements in Thai foods by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Laoharojanaphand, S.; Busamongkol, A.; Permnamtip, V.; Judprasong, K.; Chatt, A.

    2012-01-01

    A pilot study was carried out to evaluate the scope of instrumental neutron activation analysis (INAA) for measuring the levels of selected elements in a few commonly consumed food items in Thailand. Several varieties of rice, beans, aquatic food items, vegetables and soybean products were bought from major distribution centers in Bangkok, Thailand. Samples were prepared according to the protocols prescribed by the nutritionist for food compositional analysis. Levels of As, Br, Ca, Cd, Cl, Cr, Cu, Fe, K, Mg, Mn, and Zn were measured by INAA using the irradiation and counting facilities available at the Thai Research Reactor with the maximum in-core thermal neutron flux of 3 x 10 13 cm -2 s -1 of the Thailand Institute of Nuclear Technology in Bangkok. Selenium was determined by cyclic INAA using the Dalhousie University SLOWPOKE-2 Reactor facilities in Halifax, Canada at a thermal neutron flux of 2.5 x 10 11 cm -2 s -1 . Both cooked and uncooked foods were analyzed. The elemental composition of food products was found to depend significantly on the raw material as well as the preparation technique. (author)

  10. Design and Implementation Content Validity Study: Development of an instrument for measuring Patient-Centered Communication

    Directory of Open Access Journals (Sweden)

    Vahid Zamanzadeh

    2015-06-01

    Full Text Available ABSTRACT Introduction: The importance of content validity in the instrument psychometric and its relevance with reliability, have made it an essential step in the instrument development. This article attempts to give an overview of the content validity process and to explain the complexity of this process by introducing an example. Methods: We carried out a methodological study conducted to examine the content validity of the patient-centered communication instrument through a two-step process (development and judgment. At the first step, domain determination, sampling (item generation and instrument formation and at the second step, content validity ratio, content validity index and modified kappa statistic was performed. Suggestions of expert panel and item impact scores are used to examine the instrument face validity. Results: From a set of 188 items, content validity process identified seven dimensions includes trust building (eight items, informational support (seven items, emotional support (five items, problem solving (seven items, patient activation (10 items, intimacy/friendship (six items and spirituality strengthening (14 items. Content validity study revealed that this instrument enjoys an appropriate level of content validity. The overall content validity index of the instrument using universal agreement approach was low; however, it can be advocated with respect to the high number of content experts that makes consensus difficult and high value of the S-CVI with the average approach, which was equal to 0.93. Conclusion: This article illustrates acceptable quantities indices for content validity a new instrument and outlines them during design and psychometrics of patient-centered communication measuring instrument.

  11. Policy Instruments to Improve Energy Performance of Existing Owner Occupied Dwellings

    Directory of Open Access Journals (Sweden)

    Lorraine Colette Murphy

    2016-11-01

    Full Text Available The aim of this thesis is to add knowledge to the role and impact of policy instruments in meeting energy performance ambition in the existing owner occupied housing stock. The focus was instruments available in the Netherlands in 2011 and 2012. These instruments represented the ‘on the ground’ efforts to meet climate change targets and many continue to do so today in the same or slightly altered forms. At international level there is a recognized need to keep global temperatures within the range of 1.5 - 2°C above pre-industrial levels (Carrington, 2016. At European level, the 2020 package contains a series of binding legislation to help the EU meet its more immediate climate and energy targets. 2020 targets include 20% reduction in greenhouse gas emission, 20% of EU energy obtained from renewable sources and 20% improvement in energy efficiency. 2020 targets for the Netherlands are a 20% reduction in greenhouse gas emissions and a 14% increase in energy generation from renewable sources (Vringer et al., 2014. A raft of policies has been produced over the last number of decades from international to local level to orientate action towards targets. At European level the Energy Performance of Buildings Directive (EPBD drives efforts at reducing energy among one of the biggest players, the building sector. By requiring a mandatory certificate at the point of sale and rent of buildings and making regulatory demands on existing buildings the EPBD upped the ante of what could be expected from the building sector, but especially the existing dwelling stock. National governments have already been tackling existing dwellings for decades propelled by the energy crisis and later by climate change policy. Information campaigns, subsidies, energy taxes, energy loans and tailored advice are among the instruments that have been available to homeowners to carry out works on their dwellings to reduce energy consumption. In recent years, the pace of efforts

  12. Determination of levels nd interfaces in oil refinery fractioning towers, with neutron retrodispersion

    International Nuclear Information System (INIS)

    Diaz, F; Henriquez, P; Vega, P

    2003-01-01

    In the petrochemical industry and, especially, in oil refineries measurement and the control of levels and interfaces in tanks, fractioning towers and processing equipment, in general, are extremely important for managing and knowing about the different fluids that are processed in the plants. Usually there is on-line instrumentation at the plant's critical points, like floaters, external glass columns and, even, gamma radiation sources through the transmission system. A problem arises with the need for a system that can rapidly and non destructively measure levels and interfaces, outside the system to be inspected and verify the functioning of the on-line instrumentation and in places where there is no instrumentation. This work presents a methodology based on the retrodispersion of neutrons that have been used in 3 breakdown towers at the Petrox Oil Refinery, Region VIII in Chile, to identify levels and interfaces in different points in order to verify the functioning of a gamma level meter, glass column meters and to observe on site and in real time the variations in level and interfaces when carrying out different operations that will modify the values in the towers. The set of instruments used include a 1010 GBq Americium-Beryllium source and a measuring system consisting of a BF 3 (boron trifluoride) detector and its electronically related Model 2241 from Ludlum Instruments. The set is placed in a geometry that permits precise measurements (Cw)

  13. EURATOM, the year 2000 and its impact on the reporting system and instrumentation

    International Nuclear Information System (INIS)

    Chare, P.J.

    1999-01-01

    Presentation includes the Y2K potential problem areas, its impact on the reporting system and instrumentation as well as achievements done so far. The potential problem areas are: reporting system, headquarters system, installed instrumentation and stand alone instrumentation. A complete list of EURATOM equipment is listed. Specific problem areas concerned include data acquisition programmes. Reporting system is Y2K compatible, headquarters systems will be after upgrading, problems concerning instrumentation are identified and will be upgraded in 1999

  14. Robotic-surgical instrument wrist pose estimation.

    Science.gov (United States)

    Fabel, Stephan; Baek, Kyungim; Berkelman, Peter

    2010-01-01

    The Compact Lightweight Surgery Robot from the University of Hawaii includes two teleoperated instruments and one endoscope manipulator which act in accord to perform assisted interventional medicine. The relative positions and orientations of the robotic instruments and endoscope must be known to the teleoperation system so that the directions of the instrument motions can be controlled to correspond closely to the directions of the motions of the master manipulators, as seen by the the endoscope and displayed to the surgeon. If the manipulator bases are mounted in known locations and all manipulator joint variables are known, then the necessary coordinate transformations between the master and slave manipulators can be easily computed. The versatility and ease of use of the system can be increased, however, by allowing the endoscope or instrument manipulator bases to be moved to arbitrary positions and orientations without reinitializing each manipulator or remeasuring their relative positions. The aim of this work is to find the pose of the instrument end effectors using the video image from the endoscope camera. The P3P pose estimation algorithm is used with a Levenberg-Marquardt optimization to ensure convergence. The correct transformations between the master and slave coordinate frames can then be calculated and updated when the bases of the endoscope or instrument manipulators are moved to new, unknown, positions at any time before or during surgical procedures.

  15. Instruments to Identify Commercially Sexually Exploited Children: Feasibility of Use in an Emergency Department Setting.

    Science.gov (United States)

    Armstrong, Stephanie

    2017-12-01

    This review examines the screening instruments that are in existence today to identify commercially sexually exploited children. The instruments are compared and evaluated for their feasibility of use in an emergency department setting. Four electronic databases were searched to identify screening instruments that assessed solely for commercial sexual exploitation. Search terms included "commercially sexually exploited children," "CSEC," "domestic minor sex trafficking," "DMST," "juvenile sex trafficking," and "JST." Those terms were then searched in combination with each of the following: "tools," "instruments," "screening," "policies," "procedures," "data collection," "evidence," and "validity." Six screening instruments were found to meet the inclusion criteria. Variation among instruments included number of questions, ease of administration, information sources, scoring methods, and training information provided. Two instruments were determined to be highly feasible for use in the emergency department setting, those being the Asian Health Services and Banteay Srei's CSEC Screening Protocol and Greenbaum et al's CSEC/child sex trafficking 6-item screening tool. A current dearth of screening instruments was confirmed. It is recommended that additional screening instruments be created to include developmentally appropriate instruments for preadolescent children. Numerous positive features were identified within the instruments in this review and are suggested for use in future screening instruments, including succinctness, a simple format, easy administration, training materials, sample questions, multiple information sources, designation of questions requiring mandatory reporting, a straightforward scoring system, and an algorithm format.

  16. Practical implications of neutron survey instrument performance

    International Nuclear Information System (INIS)

    Tanner, R. J.; Bartlett, D. T.; Hager, I. G.; Jones, I. N.; Molinos, C.; Roberts, N. J.; Taylor, G. C.; Thomas, D. J.

    2004-01-01

    Improvements have been made to the Monte Carlo modelling used to calculate the response of the neutron survey instruments most commonly used in the UK, for neutron energies up to 20 MeV. The improved modelling of the devices includes the electronics and battery pack, allowing better calculations of both the energy and angle dependence of response. These data are used to calculate the response of the instruments in rotationally and fully isotropic, as well as unidirectional fields. Experimental measurements with radionuclide sources and monoenergetic neutron fields have been, and continue to be made, to test the calculated response characteristics. The enhancements to the calculations have involved simulation of the sensitivity of the response to variations in instrument manufacture, and will include the influence of the user and floor during measurements. The practical implications of the energy and angle dependence of response, variations in manufacture, and the influence of the user are assessed by folding the response characteristics with workplace energy and direction distributions. (authors)

  17. Overpowering posterior lumbar instrumentation and fusion with hyperlordotic anterior lumbar interbody cages followed by posterior revision: a preliminary feasibility study.

    Science.gov (United States)

    Kadam, Abhijeet; Wigner, Nathan; Saville, Philip; Arlet, Vincent

    2017-12-01

    OBJECTIVE The authors' aim in this study was to evaluate whether sagittal plane correction can be obtained from the front by overpowering previous posterior instrumentation and/or fusion with hyperlordotic anterior lumbar interbody fusion (ALIF) cages in patients undergoing revision surgery for degenerative spinal conditions and/or spinal deformities. METHODS The authors report their experience with the application of hyperlordotic cages at 36 lumbar levels for ALIFs in a series of 20 patients who underwent revision spinal surgery at a single institution. Included patients underwent staged front-back procedures: ALIFs with hyperlordotic cages (12°, 20°, and 30°) followed by removal of posterior instrumentation and reinstrumentation from the back. Patients were divided into the following 2 groups depending on the extent of posterior instrumentation and fusion during the second stage: long constructs (≥ 6 levels with extension into thoracic spine and/or pelvis) and short constructs (lumbar lordosis increased from 44.3° to 59.8° (p lumbar levels that have pseudarthrosis from the previous posterior spinal fusion. Meticulous selection of levels for ALIF is crucial for safely and effectively performing this technique.

  18. Combining climate and energy policies: synergies or antagonism? Modeling interactions with energy efficiency instruments

    International Nuclear Information System (INIS)

    Lecuyer, Oskar; Bibas, Ruben

    2012-01-01

    In addition to the already present Climate and Energy package, the European Union (EU) plans to include a binding target to reduce energy consumption. We analyze the rationales the EU invokes to justify such an overlapping and develop a minimal common framework to study interactions arising from the combination of instruments reducing emissions, promoting renewable energy (RE) production and reducing energy demand through energy efficiency (EE) investments. We find that although all instruments tend to reduce GHG emissions and although a price on carbon tends also to give the right incentives for RE and EE, the combination of more than one instrument leads to significant antagonisms regarding major objectives of the policy package. The model allows to show in a single framework and to quantify the antagonistic effects of the joint promotion of RE and EE. We also show and quantify the effects of this joint promotion on ETS permit price, on wholesale market price and on energy production levels. (authors)

  19. 77 FR 61737 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2012-10-11

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... level of export controls applicable to sensors and instrumentation equipment and technology. Agenda...

  20. 75 FR 1339 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2010-01-11

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... level of export controls applicable to sensors and instrumentation equipment and technology. Agenda...

  1. 77 FR 2270 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2012-01-17

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... the level of export controls applicable to sensors and instrumentation equipment and technology...

  2. 78 FR 1198 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2013-01-08

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... level of export controls applicable to sensors and instrumentation equipment and technology. Agenda...

  3. 76 FR 323 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2011-01-04

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... level of export controls applicable to sensors and instrumentation equipment and technology. Agenda...

  4. 78 FR 63161 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting...

    Science.gov (United States)

    2013-10-23

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting ``Rescheduled'' The Sensors and Instrumentation... that affect the level of export controls applicable to sensors and instrumentation equipment and...

  5. 78 FR 19638 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2013-04-02

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... level of export controls applicable to sensors and instrumentation equipment and technology. Agenda...

  6. 76 FR 63607 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2011-10-13

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... level of export controls applicable to sensors and instrumentation equipment and technology. Agenda...

  7. 78 FR 60251 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2013-10-01

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... level of export controls applicable to sensors and instrumentation equipment and technology. [[Page...

  8. 75 FR 62508 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting

    Science.gov (United States)

    2010-10-12

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting The Sensors and Instrumentation Technical Advisory... level of export controls applicable to sensors and instrumentation equipment and technology. Agenda...

  9. Nuclear electronic instrument systems using the Harwell 6000 series

    International Nuclear Information System (INIS)

    Seymour, F.D.; Snelling, G.F.; Hawthorn, I.

    1980-01-01

    This report describes some of the more recent equipment designed by the Systems Instrumentation Unit (AERE, Harwell), in the Harwell 6000 modular format. The units include: Laboratory Instruments (alpha monitors, beta-gamma detectors, spectrometers, automatic sample changer systems, automated counting laboratory systems, low power systems). Environmental Monitors (nuclear plant monitor, air monitor, sea bed monitor). Process Instruments (plutonium waste control, x-ray fluorescence monitor, process monitor, beam current monitor, effluent monitors). (U.K.)

  10. Next Generation UV Coronagraph Instrumentation for Solar Cycle-24

    Indian Academy of Sciences (India)

    2016-01-27

    Jan 27, 2016 ... New concepts for next generation instrumentation include imaging ultraviolet spectrocoronagraphs and large aperture ultraviolet coronagraph spectrometers. An imaging instrument would be the first to obtain absolute spectral line intensities of the extended corona over a wide field of view. Such images ...

  11. Efficient and inefficient aspects of residential energy behaviour: What are the policy instruments for change?

    International Nuclear Information System (INIS)

    Linden, Anna-Lisa; Carlsson-Kanyama, Annika; Eriksson, Bjoern

    2006-01-01

    The empirical part of this study is based on a survey of 600 Swedish households and a number of interviews where questions about residential energy behaviour and possible policy instruments for change were raised. The study provides insight into current behavioural patterns and gives a bottom-up perspective on the realistic perspective potentials for change and ways to achieve them. Residential energy use accounts for a fifth of the total in Northern nations and patterns of behaviour may influence levels of energy use to the same extent as choice of appliances. The study revealed those behavioural patterns that are efficient and those that need to be improved for energy conservation. Several policy instruments for change were identified in the study and they include combinations of information, economic measures, administrative measures and more user friendly technology as well as equipment with sufficient esthetic quality. Policy instruments that have fostered energy efficient behaviour in Sweden include the massive information campaigns during the oil crises in the 1970s as well as energy labelling of appliances. Still, many households are 'energy-unaware' and several energy efficient behaviours are motivated not by energy conservation concern but of a perceived lack of time. This shows that it is important to have a broad perspective in energy conservation, to evaluate trends and to use policy instruments timely to support or discourage them

  12. Efficient and inefficient aspects of residential energy behaviour: What are the policy instruments for change?

    Energy Technology Data Exchange (ETDEWEB)

    Linden, Anna-Lisa [Department of Sociology, Lund University, P.O. Box 114, SE-221 00 Lund (Sweden)]. E-mail: anna-lisa.linden@soc.lu.se; Carlsson-Kanyama, Annika [Department of Environmental Strategies Research, FOI, SE-172 90 Stockholm (Sweden); Eriksson, Bjoern [Department of Environmental Strategies Research, FOI, SE-172 90 Stockholm (Sweden)

    2006-09-15

    The empirical part of this study is based on a survey of 600 Swedish households and a number of interviews where questions about residential energy behaviour and possible policy instruments for change were raised. The study provides insight into current behavioural patterns and gives a bottom-up perspective on the realistic perspective potentials for change and ways to achieve them. Residential energy use accounts for a fifth of the total in Northern nations and patterns of behaviour may influence levels of energy use to the same extent as choice of appliances. The study revealed those behavioural patterns that are efficient and those that need to be improved for energy conservation. Several policy instruments for change were identified in the study and they include combinations of information, economic measures, administrative measures and more user friendly technology as well as equipment with sufficient esthetic quality. Policy instruments that have fostered energy efficient behaviour in Sweden include the massive information campaigns during the oil crises in the 1970s as well as energy labelling of appliances. Still, many households are 'energy-unaware' and several energy efficient behaviours are motivated not by energy conservation concern but of a perceived lack of time. This shows that it is important to have a broad perspective in energy conservation, to evaluate trends and to use policy instruments timely to support or discourage them.

  13. Performance and quality control of nuclear medicine instrumentation

    International Nuclear Information System (INIS)

    Paras, P.

    1981-01-01

    The status and the recent developments of nuclear medicine instrumentation performance, with an emphasis on gamma-camera performance, are discussed as the basis for quality control. New phantoms and techniques for the measurement of gamma-camera performance parameters are introduced and their usefulness for quality control is discussed. Tests and procedures for dose calibrator quality control are included. Also, the principles of quality control, tests, equipment and procedures for each type of instrument are reviewed, and minimum requirements for an effective quality assurance programme for nuclear medicine instrumentation are suggested. (author)

  14. Operating room sound level hazards for patients and physicians.

    Science.gov (United States)

    Fritsch, Michael H; Chacko, Chris E; Patterson, Emily B

    2010-07-01

    Exposure to certain new surgical instruments and operating room devices during procedures could cause hearing damage to patients and personnel. Surgical instruments and related equipment generate significant sound levels during routine usage. Both patients and physicians are exposed to these levels during the operative cases, many of which can last for hours. The noise loads during cases are cumulative. Occupational Safety and Health Administration (OSHA) and National Institute for Occupational Safety and Health (NIOSH) standards are inconsistent in their appraisals of potential damage. Implications of the newer power instruments are not widely recognized. Bruel and Kjaer sound meter spectral recordings for 20 major instruments from 5 surgical specialties were obtained at the ear levels for the patient and the surgeon between 32 and 20 kHz. Routinely used instruments generated sound levels as high as 131 dB. Patient and operator exposures differed. There were unilateral dominant exposures. Many instruments had levels that became hazardous well within the length of an average surgical procedure. The OSHA and NIOSH systems gave contradicting results when applied to individual instruments and types of cases. Background noise, especially in its intermittent form, was also of significant nature. Some patients and personnel have additional predisposing physiologic factors. Instrument noise levels for average length surgical cases may exceed OSHA and NIOSH recommendations for hearing safety. Specialties such as Otolaryngology, Orthopedics, and Neurosurgery use instruments that regularly exceed limits. General operating room noise also contributes to overall personnel exposures. Innovative countermeasures are suggested.

  15. Economic instruments and marine litter control

    NARCIS (Netherlands)

    Oosterhuis, F.H.; Papyrakis, E.; Boteler, B.

    2014-01-01

    This paper provides a comprehensive up-to-date review of the literature on the economic instruments that can reduce marine litter. We assess their cost of implementation, level of effectiveness as well as indirect environmental and socio-economic effects (externalities) that may arise as a result of

  16. Instrument for assessing mobile technology acceptability in diabetes self-management: a validation and reliability study.

    Science.gov (United States)

    Frandes, Mirela; Deiac, Anca V; Timar, Bogdan; Lungeanu, Diana

    2017-01-01

    Nowadays, mobile technologies are part of everyday life, but the lack of instruments to assess their acceptability for the management of chronic diseases makes their actual adoption for this purpose slow. The objective of this study was to develop a survey instrument for assessing patients' attitude toward and intention to use mobile technology for diabetes mellitus (DM) self-management, as well as to identify sociodemographic characteristics and quality of life factors that affect them. We first conducted the documentation and instrument design phases, which were subsequently followed by the pilot study and instrument validation. Afterward, the instrument was administered 103 patients (median age: 37 years; range: 18-65 years) diagnosed with type 1 or type 2 DM, who accepted to participate in the study. The reliability and construct validity were assessed by computing Cronbach's alpha and using factor analysis, respectively. The instrument included statements about the actual use of electronic devices for DM management, interaction between patient and physician, attitude toward using mobile technology, and quality of life evaluation. Cronbach's alpha was 0.9 for attitude toward using mobile technology and 0.97 for attitude toward using mobile device applications for DM self-management. Younger patients (Spearman's ρ =-0.429; P higher education level (Kendall's τ =0.51; P mobile assistive applications for DM control. Moreover, patients with a higher quality of life presented a significantly more positive attitude toward using modern technology (Spearman's ρ =0.466; P mobile technology for DM self-management. Additionally, we found that even if most of the patients showed positive attitude toward mobile applications, only a moderate level of intention to indeed use them was observed. Moreover, the study indicated that barriers were truthfulness and easiness to use.

  17. Health physics instrumentation needs

    International Nuclear Information System (INIS)

    Selby, J.M.; Swinth, K.L.; Kenoyer, J.L.

    1984-10-01

    Deficiencies and desirable improvements can be identified in every technical area in which health physics instruments are employed. The needed improvements cover the full spectrum including long-term reliability, human factors, accuracy, ruggedness, ease of calibration, improved radiation response, and improved mixed field response. Some specific areas of deficiency noted along with needed improvements. 17 references

  18. Developments in analytical instrumentation

    Science.gov (United States)

    Petrie, G.

    The situation regarding photogrammetric instrumentation has changed quite dramatically over the last 2 or 3 years with the withdrawal of most analogue stereo-plotting machines from the market place and their replacement by analytically based instrumentation. While there have been few new developments in the field of comparators, there has been an explosive development in the area of small, relatively inexpensive analytical stereo-plotters based on the use of microcomputers. In particular, a number of new instruments have been introduced by manufacturers who mostly have not been associated previously with photogrammetry. Several innovative concepts have been introduced in these small but capable instruments, many of which are aimed at specialised applications, e.g. in close-range photogrammetry (using small-format cameras); for thematic mapping (by organisations engaged in environmental monitoring or resources exploitation); for map revision, etc. Another innovative and possibly significant development has been the production of conversion kits to convert suitable analogue stereo-plotting machines such as the Topocart, PG-2 and B-8 into fully fledged analytical plotters. The larger and more sophisticated analytical stereo-plotters are mostly being produced by the traditional mainstream photogrammetric systems suppliers with several new instruments and developments being introduced at the top end of the market. These include the use of enlarged photo stages to handle images up to 25 × 50 cm format; the complete integration of graphics workstations into the analytical plotter design; the introduction of graphics superimposition and stereo-superimposition; the addition of correlators for the automatic measurement of height, etc. The software associated with this new analytical instrumentation is now undergoing extensive re-development with the need to supply photogrammetric data as input to the more sophisticated G.I.S. systems now being installed by clients, instead

  19. Standardization of portable assay instrumentation: the neutron-coincidence tree

    International Nuclear Information System (INIS)

    Menlove, H.O.

    1983-01-01

    Standardization of portable neutron assay instrumentation has been achieved by using the neutron coincidence technique as a common basis for a wide range of instruments and applications. The electronics originally developed for the High-Level Neutron Coincidence Counter has been adapted to both passive- and active-assay instrumentation for field verification of bulk plutonium, inventory samples, pellets, powders, nitrates, high-enriched uranium, and materials-testing-reactor, light-water-reactor, and mixed-oxide fuel assemblies. The family of detectors developed at Los Alamos National Laboratory and their performance under in-field conditions are described. 16 figures, 3 tables

  20. Instrumental Variables in the Long Run

    DEFF Research Database (Denmark)

    Casey, Gregory; Klemp, Marc Patrick Brag

    2017-01-01

    In the study of long-run economic growth, it is common to use historical or geographical variables as instruments for contemporary endogenous regressors. We study the interpretation of these conventional instrumental variable (IV) regressions in a general, yet simple, framework. Our aim...... quantitative implications for the field of long-run economic growth. We also use our framework to examine related empirical techniques. We find that two prominent regression methodologies - using gravity-based instruments for trade and including ancestry-adjusted variables in linear regression models - have...... is to estimate the long-run causal effect of changes in the endogenous explanatory variable. We find that conventional IV regressions generally cannot recover this parameter of interest. To estimate this parameter, therefore, we develop an augmented IV estimator that combines the conventional regression...

  1. Comparison of instrumented anterior interbody fusion with instrumented circumferential lumbar fusion.

    Science.gov (United States)

    Madan, S S; Boeree, N R

    2003-12-01

    Posterior lumbar interbody fusion (PLIF) restores disc height, the load bearing ability of anterior ligaments and muscles, root canal dimensions, and spinal balance. It immobilizes the painful degenerate spinal segment and decompresses the nerve roots. Anterior lumbar interbody fusion (ALIF) does the same, but could have complications of graft extrusion, compression and instability contributing to pseudarthrosis in the absence of instrumentation. The purpose of this study was to assess and compare the outcome of instrumented circumferential fusion through a posterior approach [PLIF and posterolateral fusion (PLF)] with instrumented ALIF using the Hartshill horseshoe cage, for comparable degrees of internal disc disruption and clinical disability. It was designed as a prospective study, comparing the outcome of two methods of instrumented interbody fusion for internal disc disruption. Between April 1994 and June 1998, the senior author (N.R.B.) performed 39 instrumented ALIF procedures and 35 instrumented circumferential fusion with PLIF procedures. The second author, an independent assessor (S.M.), performed the entire review. Preoperative radiographic assessment included plain radiographs, magnetic resonance imaging (MRI) and provocative discography in all the patients. The outcome in the two groups was compared in terms of radiological improvement and clinical improvement, measured on the basis of improvement of back pain and work capacity. Preoperatively, patients were asked to fill out a questionnaire giving their demographic details, maximum walking distance and current employment status in order to establish the comparability of the two groups. Patient assessment was with the Oswestry Disability Index, quality of life questionnaire (subjective), pain drawing, visual analogue scale, disability benefit, compensation status, and psychological profile. The results of the study showed a satisfactory outcome (scorelife questionnaire) score of 71.8% (28 patients) in

  2. Screening for frailty in community-dwelling elderly subjects: Predictive validity of the modified SEGA instrument.

    Science.gov (United States)

    Oubaya, N; Dramé, M; Novella, J-L; Quignard, E; Cunin, C; Jolly, D; Mahmoudi, R

    2017-11-01

    To study the capacity of the SEGAm instrument to predict loss of independence among elderly community-dwelling subjects. The study was performed in four French departments (Ardennes, Marne, Meurthe-et-Moselle, Meuse). Subjects aged 65 years or more, living at home, who could read and understand French, with a degree of autonomy corresponding to groups 5 or 6 in the AGGIR autonomy evaluation scale were included. Assessment included demographic characteristics, comprehensive geriatric assessment, and the SEGAm instrument at baseline. Subjects had follow-up visits at home at 6 and 12 months. During follow-up, vital status and level of independence were recorded. Logistic regression was used to study predictive validity of the SEGAm instrument. Among the 116 subjects with complete follow-up, 84 (72.4%) were classed as not very frail at baseline, 23 (19.8%) as frail, and 9 (7.8%) as very frail; 63 (54.3%) suffered loss of at least one ADL or IADL at 12 months. By multivariable analysis, frailty status at baseline was significantly associated with loss of independence during the 12 months of follow-up (OR=4.52, 95% CI=1.40-14.68; p=0.01). We previously validated the SEGAm instrument in terms of feasibility, acceptability, internal structure validity, reliability, and discriminant validity. This instrument appears to be a suitable tool for screening frailty among community-dwelling elderly subjects, and could be used as a basis to plan early targeted interventions for subjects at risk of adverse outcome. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. PASSCAL Instrument Center Support for Cryoseismology: Methodologies, Challenges, Development and Instrumentation

    Science.gov (United States)

    Beaudoin, B. C.; Anderson, K. R.; Bilek, S. L.; Carpenter, P.; Childs, D.; Chung, P.; Huerta, A. D.; Lingutla, N.; Nikolaus, K.; Winberry, J. P.

    2017-12-01

    Remote portable seismic stations are, in most cases, constrained by logistics and cost. High latitude operations introduce environmental, technical and logistical challenges that require substantially more engineering work to ensure robust, high quality data return. Since 2006, IRIS PASSCAL has been funded by NSF to develop, deploy, and maintain a pool of polar specific seismic stations. At roughly the same time, PASSCAL began supporting experiments specifically targeting glacier dynamics such as the mechanisms of subglacial hydrology, basal shear stress, ice stream stick slip mechanisms, and glacier seismicity. Although much of the development for high-latitude deployments was directly applicable to cryoseismology, these new experiments introduced a unique series of challenges including high ablation, standing water, and moving stations. Our polar development objectives have focused on: Reducing station power requirements, size and weight; Extending the operational temperature of a station; Simplifying logistics; Engineering solutions that are cost effective, manufacturable, serviceable and reusable; And, developing high-latitude communications for both state-of-health and data transmission. To these ends, PASSCAL continues testing new power storage technology, refining established power systems for lighter and smaller power banks, and exploring telemetry solutions to increase high-bandwidth communication options and abilities for remote seismic stations. Further enhancing PASSCAL's ability to support cryoseismology is a recent NSF funded collaborative effort lead by Central Washing University joined by IRIS and New Mexico Tech to build a Geophysical Earth Observatory for Ice Covered Environments (GEOICE). The GEOICE instrument, power system and other integrated ancillary components are designed to require minimal installation time and logistical load (i.e., size and weight), while maximizing ease-of-use in the field and optimizing costs of instrumentation and

  4. Evolution of a Greenland Ice sheet Including Shelves and Regional Sea Level Variations

    Science.gov (United States)

    Bradley, Sarah; Reerink, Thomas; van de Wal, Roderik S. W.; Helsen, Michiel; Goelzer, Heiko

    2016-04-01

    Observational evidence, including offshore moraines and marine sediment cores infer that at the Last Glacial maximum (LGM) the Greenland ice sheet (GIS) grounded out across the Davis Strait into Baffin Bay, with fast flowing ice streams extending out to the continental shelf break along the NW margin. These observations lead to a number of questions as to weather the GIS and Laurentide ice sheet (LIS) coalesced during glacial maximums, and if so, did a significant ice shelf develop across Baffin Bay and how would such a configuration impact on the relative contribution of these ice sheets to eustatic sea level (ESL). Most previous paleo ice sheet modelling simulations of the GIS recreated an ice sheet that either did not extend out onto the continental shelf or utilised a simplified marine ice parameterisation to recreate an extended GIS, and therefore did not fully include ice shelf dynamics. In this study we simulate the evolution of the GIS from 220 kyr BP to present day using IMAU-ice; a 3D thermodynamical ice sheet model which fully accounts for grounded and floating ice, calculates grounding line migration and ice shelf dynamics. As there are few observational estimates of the long-term (yrs) sub marine basal melting rates (mbm) for the GIS, we developed a mbm parameterization within IMAU-ice controlled primarily by changes in paleo water depth. We also investigate the influence of the LIS on the GIS evolution by including relative sea level forcing's derived from a Glacial Isostatic Adjustment model. We will present results of how changes in the mbm directly impacts on the ice sheet dynamics, timing and spatial extent of the GIS at the glacial maximums, but also on the rate of retreat and spatial extent at the Last interglacial (LIG) minimum. Results indicate that with the inclusion of ice shelf dynamics, a larger GIS is generated which is grounded out into Davis strait, up to a water depth of -750 m, but significantly reduces the GIS contribution to Last

  5. Regulatory requirements and quality assurance of radiation monitoring instruments

    International Nuclear Information System (INIS)

    Narasimharao, K.L.; Sharma, Ranjit

    2005-01-01

    The successful utilisation of radiation sources in the fields of medicine and industry requires the accurate measurement of activity, exposure rate and dose. Many varieties of instruments are in use for measurement of these parameters and new ones are being developed. The criteria for the design of the radiation monitoring instrument include the type and intensity of the radiation, purpose of measurement and ruggedness of the instrument. Quality and reliability of radiation monitoring instruments ensure that individuals are adequately protected. Accuracy, response time and ruggedness are required to be as per the approved/ prescribed guidelines. Regulatory authorities outline the design and performance criteria for radiation monitoring instruments and prescribe the recommendations of international agencies such as IAEA, ICRU and ISO for radiological measurement assurance programme. National Standards Laboratories all over the world prescribe procedures for calibration of various radiation monitoring instruments. The instruments should be calibrated as per these guidelines and should be traceable to national standards. The calibration traceable to national/ international standards and documentation as well as limits stipulated by the competent authority ensures the expected performance of the instrument. (author)

  6. Musical Sound, Instruments, and Equipment

    Science.gov (United States)

    Photinos, Panos

    2017-12-01

    'Musical Sound, Instruments, and Equipment' offers a basic understanding of sound, musical instruments and music equipment, geared towards a general audience and non-science majors. The book begins with an introduction of the fundamental properties of sound waves, and the perception of the characteristics of sound. The relation between intensity and loudness, and the relation between frequency and pitch are discussed. The basics of propagation of sound waves, and the interaction of sound waves with objects and structures of various sizes are introduced. Standing waves, harmonics and resonance are explained in simple terms, using graphics that provide a visual understanding. The development is focused on musical instruments and acoustics. The construction of musical scales and the frequency relations are reviewed and applied in the description of musical instruments. The frequency spectrum of selected instruments is explored using freely available sound analysis software. Sound amplification and sound recording, including analog and digital approaches, are discussed in two separate chapters. The book concludes with a chapter on acoustics, the physical factors that affect the quality of the music experience, and practical ways to improve the acoustics at home or small recording studios. A brief technical section is provided at the end of each chapter, where the interested reader can find the relevant physics and sample calculations. These quantitative sections can be skipped without affecting the comprehension of the basic material. Questions are provided to test the reader's understanding of the material. Answers are given in the appendix.

  7. Evidence for Reduced Fatigue Resistance of Contemporary Rotary Instruments Exposed to Body Temperature.

    Science.gov (United States)

    de Vasconcelos, Rafaela Andrade; Murphy, Sarah; Carvalho, Claudio Antonio Talge; Govindjee, Rajiv G; Govindjee, Sanjay; Peters, Ove A

    2016-05-01

    The purpose of this study was to evaluate the effect of 2 different temperatures (20°C and 37°C) on the cyclic fatigue life of rotary instruments and correlate the results with martensitic transformation temperatures. Contemporary nickel-titanium rotary instruments (n = 20 each and tip size #25, including Hyflex CM [Coltene, Cuyahoga Falls, OH], TRUShape [Dentsply Tulsa Dental Specialties, Tulsa, OK], Vortex Blue [Dentsply Tulsa Dental Specialties], and ProTaper Universal [Dentsply Tulsa Dental Specialties]) were tested for cyclic fatigue at room temperature (20°C ± 1°C) and at body temperature (37°C ± 1°C). Instruments were rotated until fracture occurred in a simulated canal with an angle curvature of about 60° and a radius curvature of 3 mm; the center of the curvature was 4.5 mm from the instrument tip. The number of cycles to fracture was measured. Phase transformation temperatures for 2 instruments of each brand were analyzed by differential scanning calorimetry. Data were analyzed using the t test and 1-way analysis of variance with the significance level set at 0.05. For the tested size and at 20°C, Hyflex CM showed the highest resistance to fracture; no significant difference was found between TRUShape and Vortex Blue, whereas ProTaper Universal showed the lowest resistance to fracture. At 37°C, resistance to fatigue fracture was significantly reduced, up to 85%, for the tested instruments (P rotary instruments tested. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  8. Instrumentation and Controls Division progress report, September 1, 1980-July 1, 1982

    Energy Technology Data Exchange (ETDEWEB)

    Klobe, L.E.E. (ed.)

    1982-12-01

    Activities are reported by the Reactor Systems Section, Research Instrument Section, and the Measurement and Controls Engineering Section. Reactor system activities include dynamic analysis, survillanc and diagnostic methods, design and evaluation, detectors, facilities support, process instrumentation development, and special assignments. Activities in the Research Instrument Section include the Navy-ORNL RADIAC development program, advanced ..gamma.. and x ray detector systems, neutron detection and subcriticality measurements, circuit development, position-sensitive detectors, stand-alone computers, environmental monitoring-detectors and systems, plant security, engineering support for fusion energy division, engineering support for accelerator physics, and communications: radio, closed-circuit tv, and computer. Activities in the Measurement and Controls Engineering Section include the AVLIS program; gas centrifuge enrichment technology support; Advanced Instrumentation for Reflood Studies (AIDRS) program; instrumentation development support for fuel reprocessing; in-core experiments and reactor systems; energy, conservation, and electric power systems; computer systems; measurements research; and fossil energy studies Publications are listed. (WHK)

  9. Instrumentation and Controls Division progress report, September 1, 1980-July 1, 1982

    International Nuclear Information System (INIS)

    Klobe, L.E.E.

    1982-12-01

    Activities are reported by the Reactor Systems Section, Research Instrument Section, and the Measurement and Controls Engineering Section. Reactor system activities include dynamic analysis, survillanc and diagnostic methods, design and evaluation, detectors, facilities support, process instrumentation development, and special assignments. Activities in the Research Instrument Section include the Navy-ORNL RADIAC development program, advanced #betta# and x ray detector systems, neutron detection and subcriticality measurements, circuit development, position-sensitive detectors, stand-alone computers, environmental monitoring-detectors and systems, plant security, engineering support for fusion energy division, engineering support for accelerator physics, and communications: radio, closed-circuit tv, and computer. Activities in the Measurement and Controls Engineering Section include the AVLIS program; gas centrifuge enrichment technology support; Advanced Instrumentation for Reflood Studies (AIDRS) program; instrumentation development support for fuel reprocessing; in-core experiments and reactor systems; energy, conservation, and electric power systems; computer systems; measurements research; and fossil energy studies Publications are listed

  10. Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Engineering Test Report: AMSU-A1 EOS Instrument, (S/N 202) Qualification Level Vibration Tests of August/September 1998, (S/O 565632, OC-417) Plus Addendum A

    Science.gov (United States)

    Heffer, R.

    1998-01-01

    The purpose of this report is to present a qualification level vibration testing performed on the S/N 202, EOS AMSU-A1 Instrument was vibration tested to qualification levels per the Ref. 1 shop order. The instrument withstood the 8 g sine sweep test, the 7.5 Grms random vibration test, and the 18.75 g sine burst test in each of the three orthogonal axes. Some loss of transmissibility, however, is seen in the lower reflector after Z-axis random vibration. The test sequence was not without incidence. Failure of Channel 7 in the Limited Performance Test (LPT) performed after completion of the 1 st (X-axis) axis vibration sequence, required replacement of the DRO and subsequent re-testing of the instrument. The post-vibration comprehensive performance test (CPT) was successfully run after completion of the three axes of vibration with the replacement component installed in the instrument. Passing the CPT signified the successful completion of the S/N 202 A1 qualification vibration testing.

  11. Remote and Virtual Instrumentation Platform for Distance Learning

    Directory of Open Access Journals (Sweden)

    Tom Eppes

    2010-08-01

    Full Text Available This journal presents distance learning using the National Instruments ELVIS II and how Multisim can be combined with ELVIS II for distance learning. National Instrument’s ELVIS II is a new version that can easily be used for e-learning. It features 12 of the commonly used instruments in engineering and science laboratories, including an oscilloscope, a function generator, a variable power supply, and an isolated digital multi-meter in a low-cost and easy-to-use platform and completes integration with Multisim software for SPICE simulation, which simplifies the teaching of circuit design. As NI ELVIS II is based on LabView, designers can easily customize the 12 instruments or can create their own using the provided source code for the instruments.

  12. Design and manufacture NCS instruments for cement factories

    International Nuclear Information System (INIS)

    Nguyen Thanh Tuy; Nguyen Tien Dung; Dang Nguyet Anh; Nguyen Phuc; Khuong Thanh Tuan; Luong Duc Long; Pham Trong Quyen

    2003-01-01

    The ministry project 'Design and manufacture some of NCS instruments for cement factories' is a part of instrumentation for cement production in Vietnam. The objectives of the project include: 1/Design and manufacture the automatic control system for cement raw material mixing, connected to components X-ray analyzer through serial port of PC; 2/Design and manufacture the automatic discharge control system using gamma rays. The instruments, made by the project , for controlling the conveyor belt weighing machine can be easily improved for various types of conveyor belt weighing machines. Their mobility and software equipped can be adapted for requirement of modern cement production technology. The instruments are operating well in some cement factories and they are helping in quality control. (NHA)

  13. 21 CFR 880.6150 - Ultrasonic cleaner for medical instruments.

    Science.gov (United States)

    2010-04-01

    ... instruments by the emission of high frequency soundwaves. (b) Classification. Class I. The device, including any solutions intended for use with the device for cleaning and sanitizing the instruments, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the...

  14. Instrument performance evaluation

    International Nuclear Information System (INIS)

    Swinth, K.L.

    1993-03-01

    Deficiencies exist in both the performance and the quality of health physics instruments. Recognizing the implications of such deficiencies for the protection of workers and the public, in the early 1980s the DOE and the NRC encouraged the development of a performance standard and established a program to test a series of instruments against criteria in the standard. The purpose of the testing was to establish the practicality of the criteria in the standard, to determine the performance of a cross section of available instruments, and to establish a testing capability. Over 100 instruments were tested, resulting in a practical standard and an understanding of the deficiencies in available instruments. In parallel with the instrument testing, a value-impact study clearly established the benefits of implementing a formal testing program. An ad hoc committee also met several times to establish recommendations for the voluntary implementation of a testing program based on the studies and the performance standard. For several reasons, a formal program did not materialize. Ongoing tests and studies have supported the development of specific instruments and have helped specific clients understand the performance of their instruments. The purpose of this presentation is to trace the history of instrument testing to date and suggest the benefits of a centralized formal program

  15. Distributed Framework for Dynamic Telescope and Instrument Control

    Science.gov (United States)

    Ames, Troy J.; Case, Lynne

    2002-01-01

    Traditionally, instrument command and control systems have been developed specifically for a single instrument. Such solutions are frequently expensive and are inflexible to support the next instrument development effort. NASA Goddard Space Flight Center is developing an extensible framework, known as Instrument Remote Control (IRC) that applies to any kind of instrument that can be controlled by a computer. IRC combines the platform independent processing capabilities of Java with the power of the Extensible Markup Language (XML). A key aspect of the architecture is software that is driven by an instrument description, written using the Instrument Markup Language (IML). IML is an XML dialect used to describe graphical user interfaces to control and monitor the instrument, command sets and command formats, data streams, communication mechanisms, and data processing algorithms. The IRC framework provides the ability to communicate to components anywhere on a network using the JXTA protocol for dynamic discovery of distributed components. JXTA (see httD://www.jxta.org,) is a generalized protocol that allows any devices connected by a network to communicate in a peer-to-peer manner. IRC uses JXTA to advertise a device's IML and discover devices of interest on the network. Devices can join or leave the network and thus join or leave the instrument control environment of IRC. Currently, several astronomical instruments are working with the IRC development team to develop custom components for IRC to control their instruments. These instruments include: High resolution Airborne Wideband Camera (HAWC), a first light instrument for the Stratospheric Observatory for Infrared Astronomy (SOFIA); Submillimeter And Far Infrared Experiment (SAFIRE), a Principal Investigator instrument for SOFIA; and Fabry-Perot Interferometer Bolometer Research Experiment (FIBRE), a prototype of the SAFIRE instrument, used at the Caltech Submillimeter Observatory (CSO). Most recently, we have

  16. Clinical Evaluation of Quality of Obturation and Instrumentation Time using Two Modified Rotary File Systems with Manual Instrumentation in Primary Teeth.

    Science.gov (United States)

    Govindaraju, Lavanya; Jeevanandan, Ganesh; Subramanian, Emg

    2017-09-01

    Pulp therapy in primary teeth has been performed using various instrumentation techniques. However, the conventional instrumentation technique used for root canal preparation in primary teeth is hand instrumentation. Various Nickel-Titanium (Ni-Ti) instruments are available to perform efficient root canal preparation in primary teeth. These Ni-Ti instruments has been designed to aid in better root canal preparation in permanent teeth but are rarely used in primary teeth. It is necessary to assess the feasibility of using these adult rotary files with a modified sequence in primary teeth. To compare the quality of obturation and instrumentation time during root canal preparation using hand files and modified rotary file systems in primary molars. Forty-five primary mandibular molars were randomly assigned to three experimental groups (n=15). Group I was instrumented using k-hand files, Group II with S2 ProTaper universal file and Group III with 0.25 tip 4% taper K3 rotary file. Standardized digital radiographs were taken before and after root canal instrumentation. Root canal preparation time was also recorded. Statistical analysis of the obtained data was done using SPSS Software version 17.0. An intergroup comparison of the instrumentation time and the quality of obturation was done using ANOVA and Chi-square test with the level of significance set at 0.05. No significant differences were noted with regard to the quality of obturation (p=0.791). However, a statistically significant difference was noted in the instrumentation time between the three groups (pProTaper rotary system had significantly lesser instrumentation time when compared to that of K3 rotary system and hand file system. The hand files, S2 ProTaper Universal and K3 0.25 tip 4% taper files systems performed similarly with respect to the quality of obturation. There was a significant difference in instrumentation time with manual instrumentation compared to the modified rotary file systems in primary

  17. CORPORATE SOCIAL RESPONSIBILITY AS AN INSTRUMENT OF SUSTAINABLE DEVELOPMENT OF PRODUCTION ENTERPRISES

    Directory of Open Access Journals (Sweden)

    Ewelina GAWEŁ

    2015-07-01

    Full Text Available The paper deals with the issue of corporate social responsibility as an instrument of operationalising the paradigm of sustainable development on the microeconomic level in the sector of production enterprises. It presents a genesis and importance of CSR and indicates the most relevant essential instruments of CSR implementation on an enterprise level. The paper also analyses endogenous and exogenous benefits from implementing CSR into the business practice.

  18. Instruments assessing attitudes toward or capability regarding self-management of osteoarthritis: a systematic review of measurement properties.

    Science.gov (United States)

    Eyles, J P; Hunter, D J; Meneses, S R F; Collins, N J; Dobson, F; Lucas, B R; Mills, K

    2017-08-01

    To make a recommendation on the "best" instrument to assess attitudes toward and/or capabilities regarding self-management of osteoarthritis (OA) based on available measurement property evidence. Electronic searches were performed in MEDLINE, EMBASE, CINAHL and PsychINFO (inception to 27 December 2016). Two reviewers independently rated measurement properties using the Consensus-based Standards for the selection of Health Measurement Instruments (COSMIN) 4-point scale. Best evidence synthesis was determined by considering COSMIN ratings for measurement property results and the level of evidence available for each measurement property of each instrument. Eight studies out of 5653 publications met the inclusion criteria, with eight instruments identified for evaluation: Multidimensional Health Locus of Control (MHLC), Perceived Behavioural Control (PBC), Patient Activation Measure (PAM), Educational Needs Assessment (ENAT), Stages of Change Questionnaire in Osteoarthritis (SCQOA), Effective Consumer Scale (EC-17) and Perceived Efficacy in Patient-Physician Interactions five item (PEPPI-5) and ten item scales. Measurement properties assessed for these instruments included internal consistency (k = 8), structural validity (k = 8), test-retest reliability (k = 2), measurement error (k = 1), hypothesis testing (k = 3) and cross-cultural validity (k = 3). No information was available for content validity, responsiveness or minimal important change (MIC)/minimal important difference (MID). The Dutch PEPPI-5 demonstrated the best measurement property evidence; strong evidence for internal consistency and structural validity but limited evidence for reliability and construct validity. Although PEPPI-5 was identified as having the best measurement properties, overall there is a poor level of evidence currently available concerning measurement properties of instruments to assess attitudes toward and/or capabilities regarding osteoarthritis self-management. Further

  19. Building a framework for ergonomic research on laparoscopic instrument handles.

    Science.gov (United States)

    Li, Zheng; Wang, Guohui; Tan, Juan; Sun, Xulong; Lin, Hao; Zhu, Shaihong

    2016-06-01

    Laparoscopic surgery carries the advantage of minimal invasiveness, but ergonomic design of the instruments used has progressed slowly. Previous studies have demonstrated that the handle of laparoscopic instruments is vital for both surgical performance and surgeon's health. This review provides an overview of the sub-discipline of handle ergonomics, including an evaluation framework, objective and subjective assessment systems, data collection and statistical analyses. Furthermore, a framework for ergonomic research on laparoscopic instrument handles is proposed to standardize work on instrument design. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  20. The measurement of collaboration within healthcare settings: a systematic review of measurement properties of instruments.

    Science.gov (United States)

    Walters, Stephen John; Stern, Cindy; Robertson-Malt, Suzanne

    2016-04-01

    Register of Controlled Trials, Emerald Fulltext, MD Consult Australia, PsycARTICLES, Psychology and Behavioural Sciences Collection, PsycINFO, Informit Health Databases, Scopus, UpToDate and Web of Science. The search for unpublished studies included EThOS (Electronic Thesis Online Service), Index to Theses and ProQuest- Dissertations and Theses. The assessment of methodological quality of the included studies was undertaken using the COSMIN checklist which is a validated tool that assesses the process of design and validation of healthcare measurement instruments. An Excel spreadsheet version of COSMIN was developed for data collection which included a worksheet for extracting participant characteristics and interpretability data. Statistical pooling of data was not possible for this review. Therefore, the findings are presented in a narrative form including tables and figures to aid in data presentation. To make a synthesis of the assessments of methodological quality of the different studies, each instrument was rated by accounting for the number of studies performed with an instrument, the appraisal of methodological quality and the consistency of results between studies. Twenty-one studies of 12 instruments were included in the review. The studies were diverse in their theoretical underpinnings, target population/setting and measurement objectives. Measurement objectives included: investigating beliefs, behaviors, attitudes, perceptions and relationships associated with collaboration; measuring collaboration between different levels of care or within a multi-rater/target group; assessing collaboration across teams; or assessing internal participation of both teams and patients.Studies produced validity or interpretability data but none of the studies assessed all validity and reliability properties. However, most of the included studies produced a factor structure or referred to prior factor analysis. A narrative synthesis of the individual study factor structures was

  1. The quality of instruments to assess the process of shared decision making: A systematic review

    Science.gov (United States)

    Bomhof-Roordink, Hanna; Smith, Ian P.; Scholl, Isabelle; Stiggelbout, Anne M.; Pieterse, Arwen H.

    2018-01-01

    Objective To inventory instruments assessing the process of shared decision making and appraise their measurement quality, taking into account the methodological quality of their validation studies. Methods In a systematic review we searched seven databases (PubMed, Embase, Emcare, Cochrane, PsycINFO, Web of Science, Academic Search Premier) for studies investigating instruments measuring the process of shared decision making. Per identified instrument, we assessed the level of evidence separately for 10 measurement properties following a three-step procedure: 1) appraisal of the methodological quality using the COnsensus-based Standards for the selection of health status Measurement INstruments (COSMIN) checklist, 2) appraisal of the psychometric quality of the measurement property using three possible quality scores, 3) best-evidence synthesis based on the number of studies, their methodological and psychometrical quality, and the direction and consistency of the results. The study protocol was registered at PROSPERO: CRD42015023397. Results We included 51 articles describing the development and/or evaluation of 40 shared decision-making process instruments: 16 patient questionnaires, 4 provider questionnaires, 18 coding schemes and 2 instruments measuring multiple perspectives. There is an overall lack of evidence for their measurement quality, either because validation is missing or methods are poor. The best-evidence synthesis indicated positive results for a major part of instruments for content validity (50%) and structural validity (53%) if these were evaluated, but negative results for a major part of instruments when inter-rater reliability (47%) and hypotheses testing (59%) were evaluated. Conclusions Due to the lack of evidence on measurement quality, the choice for the most appropriate instrument can best be based on the instrument’s content and characteristics such as the perspective that they assess. We recommend refinement and validation of

  2. Validation of online psychometric instruments for common mental health disorders: a systematic review.

    Science.gov (United States)

    van Ballegooijen, Wouter; Riper, Heleen; Cuijpers, Pim; van Oppen, Patricia; Smit, Johannes H

    2016-02-25

    Online questionnaires for measuring common mental health disorders such as depression and anxiety disorders are increasingly used. The psychometrics of several pen-and-paper questionnaires have been re-examined for online use and new online instruments have been developed and tested for validity as well. This study aims to review and synthesise the literature on this subject and provide a framework for future research. We searched Medline and PsycINFO for psychometric studies on online instruments for common mental health disorders and extracted the psychometric data. Studies were coded and assessed for quality by independent raters. We included 56 studies on 62 online instruments. For common instruments such as the CES-D, MADRS-S and HADS there is mounting evidence for adequate psychometric properties. Further results are scattered over different instruments and different psychometric characteristics. Few studies included patient populations. We found at least one online measure for each of the included mental health disorders and symptoms. A small number of online questionnaires have been studied thoroughly. This study provides an overview of online instruments to refer to when choosing an instrument for assessing common mental health disorders online, and can structure future psychometric research.

  3. Interaction of the EU ETS and national climate policy instruments – Impact on biomass use

    International Nuclear Information System (INIS)

    Kautto, N.; Arasto, A.; Sijm, J.; Peck, P.

    2012-01-01

    Policy-makers apply multiple policy instruments simultaneously in the climate and energy policy field at both EU and Member State levels. This creates interactions between instruments that can be complementary and synergistic but also conflicting. This article focuses on the interactions of climate policy instruments and their impact on biomass use. The objectives are to examine interactions of the EU Emissions Trading System (EU ETS) with the main national climate policy instruments and to identify the influence of these on biomass use. The work draws experiences from seven EU countries (Austria, Finland, Germany, the Netherlands, Poland, Sweden and the United Kingdom), with a special focus on Finland and Sweden. The analysis explores the effects of policy interactions and is based on an examination of literature, and interviews with biomass experts in research, industry and policy spheres. Results indicate that the combined effects of climate policy instruments have a tangible impact on biomass use, whereas the causal links to the EU ETS are difficult to assess separately. Policy impacts found include increased competition for biomass resources, changes in fuel mixes and a contribution to upward pressure on wood prices. Differences in these effects are linked to differing national policy mixes and energy-carrier portfolios – an example being the relative differences in the importance of peat to the energy mix in Finland and Sweden. Analysis and comparison of the effects in the selected countries can yield insight on how to improve the design of policy interventions that impact biomass use. This study confirms the importance of identifying interactions between policy instruments so as to recognise – and manage – synergies and conflicts. The development of more synergistic and coordinated policy instrument mixes would also be beneficial for the bioenergy field. -- Highlights: ► Combined effects of climate policy instruments have a tangible impact on biomass

  4. The Mid-Infrared Instrument for the James Webb Space Telescope, I: Introduction

    DEFF Research Database (Denmark)

    Rieke, G. H.; Wright, G. S.; Böker, T.

    2015-01-01

    MIRI (the Mid-Infrared Instrument for the James Webb Space Telescope [JWST]) operates from 5 to 28: 5 μm and combines over this range: (1) unprecedented sensitivity levels; (2) subarcsecond angular resolution; (3) freedom from atmospheric interference; (4) the inherent stability of observing...... in space; and (5) a suite of versatile capabilities including imaging, low- and medium-resolution spectroscopy (with an integral field unit), and coronagraphy. We illustrate the potential uses of this unique combination of capabilities with various science examples: (1) imaging exoplanets; (2) transit...

  5. OSIRIS (Observing System Including PolaRisation in the Solar Infrared Spectrum) instrument: a multi-directional, polarized radiometer in the visible and shortwave infrared, airborne prototype of 3MI / EPS-SG Eumetsat - ESA mission

    Science.gov (United States)

    Matar, C.; Auriol, F.; Nicolas, J. M.; Parol, F.; Riedi, J.; Djellali, M. S.; Cornet, C.; Waquet, F.; Catalfamo, M.; Delegove, C.; Loisil, R.

    2017-12-01

    OSIRIS instrument largely inherits from the POLDER concept developed and operated between 1991 (first airborne prototype) and 2013 (end of the POLDER-3/PARASOL space-borne mission). It consists in two optical systems, one covering the visible to near infrared range (440, 490, 670, 763, 765, 870, 910 and 940 nm) and a second one for the shortwave infrared (940, 1020, 1240, 1360, 1620 and 2200 nm). Each optical system is composed of a wide field-of-view optics (114° and 105° respectively) associated to two rotating wheels with interferential filters (spectral) and analyzers filters (polarization) respectively, and a 2D array of detectors. For each channel, radiance is measured once without analyzer, followed by sequential measurements with the three analyzers shifted by an angle of 60° to reconstruct the total and polarized radiances. The complete acquisition sequence for all spectral channels last a couple of seconds according to the chosen measurement protocol. Thanks to the large field of view of the optics, any target is seen under several viewing angles during the aircraft motion. In a first step we will present the new ground characterization of the instrument based on laboratory measurements (linearity, flat-field, absolute calibration, induced polarization, polarizers efficiency and position), the radiometric model and the Radiometric Inverted Model (RIM) used to develop the Level 1 processing chain that is used to produce level 1 products (normalized radiances, polarized or not, with viewing geometries) from the instrument generated level 0 files (Digital Counts) and attitude information from inertial system. The stray light issues will be specifically discussed. In a second step we will present in-flight radiometric and geometric methods applied to OSIRIS data in order to control and validate ground-based calibrated products: molecular scattering method and sun-glint cross-band method for radiometric calibration, glories, rainbows and sun-glint targets

  6. Predicting child maltreatment: A meta-analysis of the predictive validity of risk assessment instruments.

    Science.gov (United States)

    van der Put, Claudia E; Assink, Mark; Boekhout van Solinge, Noëlle F

    2017-11-01

    Risk assessment is crucial in preventing child maltreatment since it can identify high-risk cases in need of child protection intervention. Despite widespread use of risk assessment instruments in child welfare, it is unknown how well these instruments predict maltreatment and what instrument characteristics are associated with higher levels of predictive validity. Therefore, a multilevel meta-analysis was conducted to examine the predictive accuracy of (characteristics of) risk assessment instruments. A literature search yielded 30 independent studies (N=87,329) examining the predictive validity of 27 different risk assessment instruments. From these studies, 67 effect sizes could be extracted. Overall, a medium significant effect was found (AUC=0.681), indicating a moderate predictive accuracy. Moderator analyses revealed that onset of maltreatment can be better predicted than recurrence of maltreatment, which is a promising finding for early detection and prevention of child maltreatment. In addition, actuarial instruments were found to outperform clinical instruments. To bring risk and needs assessment in child welfare to a higher level, actuarial instruments should be further developed and strengthened by distinguishing risk assessment from needs assessment and by integrating risk assessment with case management. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Absorption coefficient instrument for turbid natural waters

    Science.gov (United States)

    Friedman, E.; Cherdak, A.; Poole, L.; Houghton, W.

    1980-01-01

    The paper presents an instrument that directly measures multispectral absorption coefficient of turbid natural water. Attention is given to the design, which is shown to incorporate methods for the compensation of variation in the internal light source intensity, correction of the spectrally dependent nature of the optical elements, and correction for variation in the background light level. In addition, when used in conjunction with a spectrally matched total attenuation instrument, the spectrally dependent scattering coefficient can also be derived. Finally, it is reported that systematic errors associated with multiple scattering have been estimated using Monte Carlo techniques.

  8. Magnetospheric Multiscale Instrument Suite Operations and Data System

    Science.gov (United States)

    Baker, D. N.; Riesberg, L.; Pankratz, C. K.; Panneton, R. S.; Giles, B. L.; Wilder, F. D.; Ergun, R. E.

    2016-03-01

    The four Magnetospheric Multiscale (MMS) spacecraft will collect a combined volume of ˜100 gigabits per day of particle and field data. On average, only 4 gigabits of that volume can be transmitted to the ground. To maximize the scientific value of each transmitted data segment, MMS has developed the Science Operations Center (SOC) to manage science operations, instrument operations, and selection, downlink, distribution, and archiving of MMS science data sets. The SOC is managed by the Laboratory for Atmospheric and Space Physics (LASP) in Boulder, Colorado and serves as the primary point of contact for community participation in the mission. MMS instrument teams conduct their operations through the SOC, and utilize the SOC's Science Data Center (SDC) for data management and distribution. The SOC provides a single mission data archive for the housekeeping and science data, calibration data, ephemerides, attitude and other ancillary data needed to support the scientific use and interpretation. All levels of data products will reside at and be publicly disseminated from the SDC. Documentation and metadata describing data products, algorithms, instrument calibrations, validation, and data quality will be provided. Arguably, the most important innovation developed by the SOC is the MMS burst data management and selection system. With nested automation and "Scientist-in-the-Loop" (SITL) processes, these systems are designed to maximize the value of the burst data by prioritizing the data segments selected for transmission to the ground. This paper describes the MMS science operations approach, processes and data systems, including the burst system and the SITL concept.

  9. Musical instrument technology of the 20th century

    Science.gov (United States)

    Wheeler, Paul

    2004-05-01

    This paper presents a brief history of the technical development of musical instruments during the 20th century. Starting with early electronic instruments (such as the Theremin-1917) invented prior to the organization of ASA, the history includes the development of electronic organs, synthesizers, and computer music. This paper provides an introduction to the session, giving a framework for the papers which follow in the session.

  10. Performing the Super Instrument

    DEFF Research Database (Denmark)

    Kallionpaa, Maria

    2016-01-01

    can empower performers by producing super instrument works that allow the concert instrument to become an ensemble controlled by a single player. The existing instrumental skills of the performer can be multiplied and the qualities of regular acoustic instruments extended or modified. Such a situation......The genre of contemporary classical music has seen significant innovation and research related to new super, hyper, and hybrid instruments, which opens up a vast palette of expressive potential. An increasing number of composers, performers, instrument designers, engineers, and computer programmers...... have become interested in different ways of “supersizing” acoustic instruments in order to open up previously-unheard instrumental sounds. Super instruments vary a great deal but each has a transformative effect on the identity and performance practice of the performing musician. Furthermore, composers...

  11. Digital readout alpha survey instrument

    International Nuclear Information System (INIS)

    Jacobs, M.E.

    1976-01-01

    A prototype solid-state digital readout alpha particle survey instrument has been designed and constructed. The meter incorporates a Ludlum alpha scintillator as a detector, digital logic circuits for control and timing, and a Digilin counting module with reflective liquid crystal display. The device is used to monitor alpha radiation from a surface. Sample counts are totalized over 10-second intervals and displayed digitally in counts per minute up to 19,999. Tests over source samples with counts to 15,600 cpm have shown the device to be rapid, versatile and accurate. The instrument can be fabricated in one man-week and requires about $835 in material costs. A complete set of drawings is included

  12. An intelligent instrument for measuring the dynamic parameters of groundwater

    International Nuclear Information System (INIS)

    Du Guoping

    2002-01-01

    An intelligent instrument was developed for measuring direction and velocity of the groundwater, permeability coefficient, hydraulic transmitting coefficient, static level, hydraulic gradient and flow direction of each layer. The instrument can be widely applied for detecting seepage of abutment and river bank, exploitation of groundwater, conservation of water and soil, water surging in mine, survey of groundwater resource and environment protection etc

  13. MHTGR steam generator on-line heat balance, instrumentation and function

    International Nuclear Information System (INIS)

    Klapka, R.E.; Howard, W.W.; Etzel, K.T.; Basol, M.; Karim, N.U.

    1991-09-01

    Instrumentation is used to measure the Modular High Temperature Gas-Cooled Reactor (MHTGR) steam generator dissimilar metal weld temperature during start-up testing. Additional instrumentation is used to determine an on-line heat balance which is maintained during the 40 year module life. In the process of calibrating the on-line heat balance, the helium flow is adjusted to yield the optimum boiling level in the steam generator relative to the dissimilar metal weld. After calibration is complete the weld temperature measurement is non longer required. The reduced boiling level range results in less restrictive steam generator design constraints

  14. Instrumental delivery: clinical practice guidelines from the French College of Gynaecologists and Obstetricians.

    Science.gov (United States)

    Vayssière, Christophe; Beucher, Gael; Dupuis, Olivier; Feraud, Olivia; Simon-Toulza, Caroline; Sentilhes, Loïc; Meunier, Emmanuelle; Parant, Olivier; Schmitz, Thomas; Riethmuller, Didier; Baud, Olivier; Galley-Raulin, Fabienne; Diemunsch, Pierre; Pierre, Fabrice; Schaal, Jean-Patrick; Fournié, Alain; Oury, Jean François

    2011-11-01

    Routine use of a partograph is associated with a reduction in the use of forceps, but is not associated with a reduction in the use of vacuum extraction (Level A). Early artificial rupture of the membranes, associated with oxytocin perfusion, does not reduce the number of operative vaginal deliveries (Level A), but does increase the rate of fetal heart rate abnormalities (Level B). Early correction of lack of progress in dilatation by oxytocin perfusion can reduce the number of operative vaginal deliveries (Level B). The use of low-concentration epidural infusions of bupivacaine potentiated by morphinomimetics reduces the number of operative interventions compared with larger doses (Level A). Placement of an epidural before 3-cm dilatation does not increase the number of operative vaginal deliveries (Level A). Posterior positions of the fetus result in more operative vaginal deliveries (Level B). Manual rotation of the fetus from a posterior position to an anterior position may reduce the number of operative deliveries (Level C). Walking during labour is not associated with a reduction in the number of operative vaginal deliveries (Level A). Continuous support of the parturient by a midwife or partner/family member during labour reduces the number of operative vaginal deliveries (Level A). Under epidural analgesia, delayed pushing (2h after full dilatation) reduces the number of difficult operative vaginal deliveries (Level A). Ultrasound is recommended if there is any clinical doubt about the presentation of the fetus (Level B). The available scientific data are insufficient to contra-indicate attempted midoperative delivery (professional consensus). The duration of the operative intervention is slightly shorter with forceps than with a vacuum extractor (Level C). Nonetheless, the urgency of operative delivery is not a reason to choose one instrument over another (professional consensus). The cup-shaped vacuum extractor seems to be the instrument of choice for

  15. [Development and validation of an instrument for initial nursing assessment].

    Science.gov (United States)

    Fernández-Sola, Cayetano; Granero-Molina, José; Mollinedo-Mallea, Judith; de Gonzales, María Hilda Peredo; Aguilera-Manrique, Gabriel; Ponce, Mara Luna

    2012-12-01

    The objective of this study, conducted in Bolivia from April to July of 2008, is the design and validation of an initial nursing assessment instrument to be used in clinical and educational environments in Santa Cruz (Bolivia). Twelve Bolivian nurses participated; both document analysis as well as consensus techniques were used to determine the categories and criteria to be assessed. Categories included in the nursing assessment instrument are a physical assessment and the eleven Gordon's Functional Health Patterns. The nursing assessment instrument stands out as being concise, easy to complete and utilizing a nursing approach. It does not include items for advanced nursing assessment. However, it incorporates items regarding lifestyle and the patient's autonomy. The nursing assessment instrument contributes to improving the quality of clinical records, supports the nursing diagnosis and implementation of the nursing process, promotes the nurse's role and helps to standardize practice.

  16. Validity and Reliability of Turkish Male Breast Self-Examination Instrument.

    Science.gov (United States)

    Erkin, Özüm; Göl, İlknur

    2018-04-01

    This study aims to measure the validity and reliability of Turkish male breast self-examination (MBSE) instrument. The methodological study was performed in 2016 at Ege University, Faculty of Nursing, İzmir, Turkey. The MBSE includes ten steps. For validity studies, face validity, content validity, and construct validity (exploratory factor analysis) were done. For reliability study, Kuder Richardson was calculated. The content validity index was found to be 0.94. Kendall W coefficient was 0.80 (p=0.551). The total variance explained by the two factors was found to be 63.24%. Kuder Richardson 21 was done for reliability study and found to be 0.97 for the instrument. The final instrument included 10 steps and two stages. The Turkish version of MBSE is a valid and reliable instrument for early diagnose. The MBSE can be used in Turkish speaking countries and cultures with two stages and 10 steps.

  17. Towards automatic musical instrument timbre recognition

    Science.gov (United States)

    Park, Tae Hong

    This dissertation is comprised of two parts---focus on issues concerning research and development of an artificial system for automatic musical instrument timbre recognition and musical compositions. The technical part of the essay includes a detailed record of developed and implemented algorithms for feature extraction and pattern recognition. A review of existing literature introducing historical aspects surrounding timbre research, problems associated with a number of timbre definitions, and highlights of selected research activities that have had significant impact in this field are also included. The developed timbre recognition system follows a bottom-up, data-driven model that includes a pre-processing module, feature extraction module, and a RBF/EBF (Radial/Elliptical Basis Function) neural network-based pattern recognition module. 829 monophonic samples from 12 instruments have been chosen from the Peter Siedlaczek library (Best Service) and other samples from the Internet and personal collections. Significant emphasis has been put on feature extraction development and testing to achieve robust and consistent feature vectors that are eventually passed to the neural network module. In order to avoid a garbage-in-garbage-out (GIGO) trap and improve generality, extra care was taken in designing and testing the developed algorithms using various dynamics, different playing techniques, and a variety of pitches for each instrument with inclusion of attack and steady-state portions of a signal. Most of the research and development was conducted in Matlab. The compositional part of the essay includes brief introductions to "A d'Ess Are ," "Aboji," "48 13 N, 16 20 O," and "pH-SQ." A general outline pertaining to the ideas and concepts behind the architectural designs of the pieces including formal structures, time structures, orchestration methods, and pitch structures are also presented.

  18. Novel seismic instrumentation for nuclear power plants

    International Nuclear Information System (INIS)

    Bolleter, W.; Savary, C.

    1998-01-01

    Conforming to the latest issues of the Nuclear Regulatory Commission Regulatory Guide, a novel hardware and software solution for seismic instrumentation is presented. Both instrumentation and PC-based data evaluation software for post-earthquake actions are type-tested and approved by the German TUeV. Reference installations replacing obsolete analog instrumentation were successfully completed and are presented. The instrumentation consists of highly linear, solid-state capacitive accelerometers as well as digital recorders storing the signals from the sensors in situ. These recorders are linked in a star-topology network to a central unit that permanently communicates with them via fiber-optic cable or current-loop links. The central unit is responsible for alerting and synchronizes all recorders which otherwise act autonomously. Data evaluation is handled by a PC-based software package. It includes automatic data evaluation after earthquakes (batch mode), interactive data evaluation software for detailed data analysis, and software tools for remote operation, maintenance and data storage. (author)

  19. An overview of instrumentation for the Large Binocular Telescope

    Science.gov (United States)

    Wagner, R. Mark

    2012-09-01

    An overview of instrumentation for the Large Binocular Telescope (LBT) is presented. Optical instrumentation includes the Large Binocular Camera (LBC), a pair of wide-field (27' x 27') mosaic CCD imagers at the prime focus, and the Multi-Object Double Spectrograph (MODS), a pair of dual-beam blue-red optimized long-slit spectrographs mounted at the left and right direct F/15 Gregorian foci incorporating multiple slit masks for multi-object spectroscopy over a 6' field and spectral resolutions of up to 2000. Infrared instrumentation includes the LBT Near-IR Spectroscopic Utility with Camera and Integral Field Unit for Extragalactic Research (LUCI), a modular near-infrared (0.9-2.5 μm) imager and spectrograph pair mounted at the left and right front bent F/15 Gregorian foci and designed for seeing-limited (FOV: 4' × 4') imaging, long-slit spectroscopy, and multiobject spectroscopy utilizing cooled slit masks and diffraction limited (FOV: 0'.5 × 0'.5) imaging and long-slit spectroscopy. Strategic instruments under development that can utilize the full 23-m baseline of the LBT include an interferometric cryogenic beam combiner with near-infrared and thermal-infrared instruments for Fizeau imaging and nulling interferometry (LBTI) and an optical bench near-infrared beam combiner utilizing multi-conjugate adaptive optics for high angular resolution and sensitivity (LINC-NIRVANA). LBTI is currently undergoing commissioning on the LBT and utilizing the installed adaptive secondary mirrors in both single- sided and two-sided beam combination modes. In addition, a fiber-fed bench spectrograph (PEPSI) capable of ultra high resolution spectroscopy and spectropolarimetry (R = 40,000-300,000) will be available as a principal investigator instrument. Over the past four years the LBC pair, LUCI1, and MODS1 have been commissioned and are now scheduled for routine partner science observations. The delivery of both LUCI2 and MODS2 is anticipated before the end of 2012. The

  20. Current status of some neutron instruments in Serpong

    Energy Technology Data Exchange (ETDEWEB)

    Ikram, A; Hardi, T; Maulana, A [Neutron Scattering Lab., Materials Science Research Center, BATAN-Serpong, Jakarta (Indonesia)

    1998-10-01

    Performances of the Small Angle Neutron Scattering Spectrometer, the High Resolution Small Angle Neutron Scattering Spectrometer and the High Resolution Neutron Powder Diffractometer in the last full one year are presented as well as problems, difficulties and limitations faced by each instrument. Efforts that have been done to overcome those shortcomings are also mentioned. Proposed collaboration in order to bring those instruments back to a state that can perform scientifically acceptable is described to a level that can be agreed in this workshop. (author)

  1. VIRUS instrument enclosures

    Science.gov (United States)

    Prochaska, T.; Allen, R.; Mondrik, N.; Rheault, J. P.; Sauseda, M.; Boster, E.; James, M.; Rodriguez-Patino, M.; Torres, G.; Ham, J.; Cook, E.; Baker, D.; DePoy, Darren L.; Marshall, Jennifer L.; Hill, G. J.; Perry, D.; Savage, R. D.; Good, J. M.; Vattiat, Brian L.

    2014-08-01

    The Visible Integral-Field Replicable Unit Spectrograph (VIRUS) instrument will be installed at the Hobby-Eberly Telescope† in the near future. The instrument will be housed in two enclosures that are mounted adjacent to the telescope, via the VIRUS Support Structure (VSS). We have designed the enclosures to support and protect the instrument, to enable servicing of the instrument, and to cool the instrument appropriately while not adversely affecting the dome environment. The system uses simple HVAC air handling techniques in conjunction with thermoelectric and standard glycol heat exchangers to provide efficient heat removal. The enclosures also provide power and data transfer to and from each VIRUS unit, liquid nitrogen cooling to the detectors, and environmental monitoring of the instrument and dome environments. In this paper, we describe the design and fabrication of the VIRUS enclosures and their subsystems.

  2. Advanced Instrumentation for Ultrafast Science at the LCLS

    Energy Technology Data Exchange (ETDEWEB)

    Berrah, Nora [Univ. of Connecticut, Storrs, CT (United States)

    2015-10-13

    This grant supported a Single Investigator and Small Group Research (SISGR) application to enable multi-user research in Ultrafast Science using the Linac Coherent Light Source (LCLS), the world’s first hard x-ray free electron laser (FEL) which lased for the first time at 1.5 Å on April 20, 2009. The goal of our proposal was to enable a New Era of Science by requesting funds to purchase and build Advanced Instrumentation for Ultrafast Science (AIUS), to utilize the intense, short x-ray pulses produced by the LCLS. The proposed instrumentation will allow peer review selected users to probe the ultrasmall and capture the ultrafast. These tools will expand on the investment already made in the construction of the light source and its instrumentation in both the LCLS and LUSI projects. The AIUS will provide researchers in the AMO, Chemical, Biological and Condensed Matter communities with greater flexibility in defining their scientific agenda at the LCLS. The proposed instrumentation will complement and significantly augment the present AMO instrument (funded through the LCLS project) through detectors and capabilities not included in the initial suite of instrumentation at the facility. We have built all of the instrumentations and they have been utilized by scientists. Please see report attached.

  3. Relationships between the school-level and classroom-level ...

    African Journals Online (AJOL)

    education; school-level environment; science education; South Africa. Introduction .... instrument to the primary school students (N = 1,077) of 31 distance-education primary school teachers ..... Centre for Curriculum, Transfer and Technology.

  4. Essentials of nuclear medicine physics and instrumentation

    CERN Document Server

    Powsner, Rachel A; Powsner, Edward R

    2013-01-01

    An excellent introduction to the basic concepts of nuclear medicine physics This Third Edition of Essentials of Nuclear Medicine Physics and Instrumentation expands the finely developed illustrated review and introductory guide to nuclear medicine physics and instrumentation. Along with simple, progressive, highly illustrated topics, the authors present nuclear medicine-related physics and engineering concepts clearly and concisely. Included in the text are introductory chapters on relevant atomic structure, methods of radionuclide production, and the interaction of radiation with matter. Fu

  5. Black carbon emissions in gasoline vehicle exhaust: a measurement and instrument comparison.

    Science.gov (United States)

    Kamboures, Michael A; Hu, Shishan; Yu, Yong; Sandoval, Julia; Rieger, Paul; Huang, Shiou-Mei; Zhang, Sherry; Dzhema, Inna; Huo, Darey; Ayala, Alberto; Chang, M C Oliver

    2013-08-01

    A pilot study was conducted to evaluate the performance and agreement of several commercially available black carbon (BC) measurement instruments, when applied to the quantification of BC in light-duty vehicle (LDV) exhaust. Samples from six vehicles, three fuels, and three driving cycles were used. The pilot study included determinations of the method detection limit (MDL) and repeatability. With respect to the MDL, the real-time instruments outperformed the time-integrated instruments, with MDL = 0.12 mg/mi for the AE51 Aethalometer, and 0.15 mg/mi for the Micro Soot Sensor (MSS), versus 0.38 mg/mi for the IMPROVE_A thermal/ optical method, and 0.35 mg/mi for the OT21_T Optical Transmissometer. The real-time instruments had repeatability values ranging from 30% to 35%, which are somewhat better than those of the time-integrated instruments (40-41%). These results suggest that, despite being less resource intensive, real-time methods can be equivalent or superior to time-integrated methods in terms of sensitivity and repeatability. BC mass data, from the photoacoustic and light attenuation instruments, were compared against same-test EC data, determined using the IMPROVE_A method. The MSS BC data was well correlated with EC, with R2 = 0.85 for the composite results and R2 = 0.86 for the phase-by-phase (PBP) results. The correlation of BC, by the AE51, AE22, and OT21_T with EC was moderate to weak. The weaker correlation was driven by the inclusion of US06 test data in the linear regression analysis. We hypothesize that test-cycle-dependent BC:EC ratios are due to the different physicochemical properties of particulate matter (PM) in US06 and Federal Test Procedure (FTP) tests. Correlation amongst the real-time MSS, PASS-1, AE51, and AE22 instruments was excellent (R2 = 0.83-0.95), below 1 mg/mi levels. In the process of investigating these BC instruments, we learned that BC emissions at sub-1 mg/mi levels can be measured and are achievable by current

  6. CT evaluation of canal preparation using rotary and hand NI-TI instruments: An in vitro study.

    Science.gov (United States)

    Nagaraja, Shruthi; Sreenivasa Murthy, B V

    2010-01-01

    Controlled, uniformly tapered radicular preparation is a great challenge in endodontics. Improper preparation can lead to procedural errors like transportation of foramen, uneven dentine thickness, stripping of root canal, formation of ledge, zip, and elbow in curved canals. These procedural errors and their sequel can adversely affect the prognosis of treatment. The present in vitro study aims to evaluate canal preparation based on the following factors: canal transportation, remaining dentine thickness and comparing centering ability between hand Ni-Ti K files and ProTaper rotary Ni-Ti instruments using computed tomography (CT). For evaluation, 30 mesiobuccal roots of maxillary molars were selected. Of these, 15 roots were distributed into two groups where Group 1 included hand instrumentation with Ni-Ti K-files; and Group 2 comprised ProTaper NiTi rotary system. Pre instrumentation and post instrumentation three-dimensional CT images were obtained from root cross-sections that were 1 mm thick from apex to the canal orifice; scanned images were then superimposed and compared. It was observed that the manual technique using hand Ni-Ti K-file produced lesser canal transportation and maintained greater dentine thickness than the rotary ProTaper technique at middle and coronal third and this difference was statistically significant. No significant difference was seen with regard to canal transportation and remaining root dentine at apical levels. With regard to centering ratio, no significant difference was seen between both the groups at all levels. ProTaper should be used judiciously, especially in curved canals, as it causes higher canal transportation and thinning of root dentine at middle and coronal levels. None of the groups showed optimal centering ability.

  7. Historical Trust Levels Predict Current Welfare State Design

    DEFF Research Database (Denmark)

    Bergh, Andreas; Bjørnskov, Christian

    Using cross-sectional data for 76 countries, we apply instrumental variable techniques based on pronoun drop, temperature and monarchies to demonstrate that historical trust levels predict several indicators of current welfare state design, including universalism and high levels of regulatory...... freedom. We argue that high levels of trust and trustworthiness are necessary, but not sufficient, conditions for societies to develop successful universal welfare states that would otherwise be highly vulnerable to free riding and fraudulent behavior. Our results do not exclude positive feedback from...... welfare state universalism to individual trust, although we claim that the important causal link runs from historically trust levels to current welfare state design....

  8. The progress report of the Instrumentation and Technological Electronical Division, for 1987

    International Nuclear Information System (INIS)

    1988-05-01

    The 1987 activity report of the CEA Instrumentation and Technological Electronic Division (ITED), is presented. The ITED fields of interest include nuclear, space, health, defense and civil domains. The research development and perspectives are summarized. Concerning materials and components the following research programs are included: silicon integrated circuits, silicon on isolator, common experimental laboratory, mass memory, lasers, photodetection, flat screens, and sensors. In the field of instrumentations and systems, the retained research guidelines are focused on: medical and biological instrumentation, the environment, the nuclear domain. Moreover, the research fields of physics, artificial intelligence and software, production, robots, architecture and integration are also included [fr

  9. Instrumented Impact Testing: Influence of Machine Variables and Specimen Position

    International Nuclear Information System (INIS)

    Lucon, E.; McCowan, C. N.; Santoyo, R. A.

    2008-01-01

    An investigation has been conducted on the influence of impact machine variables and specimen positioning on characteristic forces and absorbed energies from instrumented Charpy tests. Brittle and ductile fracture behavior has been investigated by testing NIST reference samples of low, high and super-high energy levels. Test machine variables included tightness of foundation, anvil and striker bolts, and the position of the center of percussion with respect to the center of strike. For specimen positioning, we tested samples which had been moved away or sideways with respect to the anvils. In order to assess the influence of the various factors, we compared mean values in the reference (unaltered) and altered conditions; for machine variables, t-test analyses were also performed in order to evaluate the statistical significance of the observed differences. Our results indicate that the only circumstance which resulted in variations larger than 5 percent for both brittle and ductile specimens is when the sample is not in contact with the anvils. These findings should be taken into account in future revisions of instrumented Charpy test standards.

  10. Instrumented Impact Testing: Influence of Machine Variables and Specimen Position

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E.; McCowan, C. N.; Santoyo, R. A.

    2008-09-15

    An investigation has been conducted on the influence of impact machine variables and specimen positioning on characteristic forces and absorbed energies from instrumented Charpy tests. Brittle and ductile fracture behavior has been investigated by testing NIST reference samples of low, high and super-high energy levels. Test machine variables included tightness of foundation, anvil and striker bolts, and the position of the center of percussion with respect to the center of strike. For specimen positioning, we tested samples which had been moved away or sideways with respect to the anvils. In order to assess the influence of the various factors, we compared mean values in the reference (unaltered) and altered conditions; for machine variables, t-test analyses were also performed in order to evaluate the statistical significance of the observed differences. Our results indicate that the only circumstance which resulted in variations larger than 5 percent for both brittle and ductile specimens is when the sample is not in contact with the anvils. These findings should be taken into account in future revisions of instrumented Charpy test standards.

  11. Concurrent validation of two key health literacy instruments in a South Eastern European population.

    Science.gov (United States)

    Toçi, Ervin; Burazeri, Genc; Sørensen, Kristine; Kamberi, Haxhi; Brand, Helmut

    2015-06-01

    Public health practice has come to increasing recognition of health promotion and the central role of knowledge, attitude, beliefs and practices in achieving health promotion. Health literacy (HL) is an under-explored topic in South Eastern European countries. There are no HL reports from Albania to date. The aim of this study was to assess the concurrent validity of the European Health Literacy Survey Questionnaire (HLS-EU-Q) and the Test of Functional Health Literacy in Adults (TOFHLA) in a population-based sample of adults in Albania. A cross-sectional study was conducted in 2013 in Tirana, Albania, including 239 individuals aged ≥ 18 years (61% women; 87% response). A structured interviewer-administered questionnaire was applied twice (test and retest procedure after 2 weeks) including HLS-EU-Q and TOFHLA instruments. The internal consistency was high for both instruments (Cronbach's alpha for the test procedure was 0.92 for TOFHLA and 0.98 for HLS-EU-Q). Both tools exhibited a high stability over time (Spearman's rho: 0.88 for TOFHLA and 0.87 for HLS-EU). Mean values of both instruments were similar in men and women (mean score for TOFHLA: 76.0 vs. 76.5, P = 0.83; mean score for HLS-EU-Q: 32.2 vs. 32.6, P = 0.63). For both instruments, higher HL scores were significantly associated with younger age, higher educational and economic level and lower body mass index. Our study provides valuable novel evidence on concurrent validation of two major HL instruments in a South Eastern European population-based sample. Future studies should be conducted in order to confirm and expand our findings. © The Author 2014. Published by Oxford University Press on behalf of the European Public Health Association. All rights reserved.

  12. Economic instruments for population diet and physical activity behaviour change: a systematic scoping review.

    Directory of Open Access Journals (Sweden)

    Ian Shemilt

    Full Text Available Unhealthy diet and low levels of physical activity are common behavioural factors in the aetiology of many non-communicable diseases. Recent years have witnessed an upsurge of policy and research interest in the use of taxes and other economic instruments to improve population health.To assemble, configure and analyse empirical research studies available to inform the public health case for using economic instruments to promote dietary and physical activity behaviour change.We conducted a systematic scoping review of evidence for the effects of specific interventions to change, or general exposure to variations in, prices or income on dietary and physical activity behaviours and corollary outcomes. Systematic electronic searches and parallel snowball searches retrieved >1 million study records. Text mining technologies were used to prioritise title-abstract records for screening. Eligible studies were selected, classified and analysed in terms of key characteristics and principal findings, using a narrative, configuring synthesis focused on implications for policy and further research.We identified 880 eligible studies, including 192 intervention studies and 768 studies that incorporated evidence for prices or income as correlates or determinants of target outcomes. Current evidence for the effects of economic instruments and exposures on diet and physical activity is limited in quality and equivocal in terms of its policy implications. Direct evidence for the effects of economic instruments is heavily skewed towards impacts on diet, with a relative lack of evidence for impacts on physical activity.The evidence-based case for using economic instruments to promote dietary and physical activity behaviour change may be less compelling than some proponents have claimed. Future research should include measurement of people's actual behavioural responses using study designs capable of generating reliable causal inferences regarding intervention

  13. Operational Test Instrumentation Guide.

    Science.gov (United States)

    1981-11-01

    System. A topographic, transit-level measuring system, instrumented with altimeter, clinometers, compasses , and an alidade, plane table, and stadia rod...dual hangar 250 x 135 feet with two door openings, 80 feet each. There is no compass swing base, no electronic landing aids, ro aircraft wash or...month) of SDG &E) Haybarn Canyon 15,000 6,183,870 Lan Pulgas 1,500 433,890 Las Pulgas Well #41621 100 4,258 Las Pulgas Well #41611 150 7,548 Las Flores

  14. Radiological safety related provisions and instrumentation in Indian PHWRs

    International Nuclear Information System (INIS)

    Ramamirtham, B.; Dabhadkar, S.B.; Sah, B.M.L.

    1994-01-01

    The collective radiation doses at the nuclear power plants (NPPs) world-wide have shown a significant downward trend which has resulted due to on-going efforts to keep exposures ALARA and also to meet the recently revised individual exposure limits of ICRP. In keeping with this trend a number of additional designed dose reduction features are also being incorporated in the Indian NPPs. These include better separation and shielding of radioactive systems/equipment, elimination of the use of cobalt-free materials in active systems, improved leak tightness of systems carrying heavy water, augmented ventilation and atmosphere drying systems, etc. The build-up of radiation levels in primary heat transport (PHT) system is controlled by incorporating improvements in the fuel performance and periodic system decontamination. Plant layouts have been modified, to improve the contamination control arrangements and optimum utilisation of dosimetry devices. For better control of internal exposures continuous efforts are on to make the protective gear more user-friendly. Green belts are being established around the NPPs to provide further protection against environmental impact. A number of additional radiation monitoring instruments /systems have been incorporated to provide information on radiation/activity levels, both within the plant and outside areas, particularly during emergency conditions. For processing of data provided by the large numbers of installed radiation instruments and initiating corrective/alarm actions, a computerised system (RADAS) has been provided. (author). 7 refs., 2 tabs

  15. INNOVATIVE FINANCIAL INSTRUMENTS IN THE EXECUTION OF EUROPEAN UNION BUDGET

    Directory of Open Access Journals (Sweden)

    FLOREA IANC MARIA MIRABELA

    2017-12-01

    obvious long-term benefits of fund recycling, financial instruments contribute to mobilizing additional public or private co-investments to address market failures, in line with the priorities of the Europe 2020 strategy and cohesion policy. Their implementation structures involve a wealth of expertise and know-how, which contributes to increasing the efficiency and effectiveness of public resource allocation. Moreover, these tools provide a wide range of incentives to improve performance, including greater financial discipline at the level of supported projects.

  16. Safeguards instrumentation: a computer-based catalog. Second edition

    International Nuclear Information System (INIS)

    Auerbach, C.

    1985-04-01

    This catalog contains entries on new developments and on items listed in BNL 51450, which have either been carried over unchanged or been updated. More than 70 entries were deleted because of either obsolescence, insufficient interest in terms of safeguards, or lack of documentable development activities in recent years. Some old listings as well as new material was consolidated into more generic entries. As in the earlier document, the emphasis is on devices and instruments that are either in field use at this time or under active development. A few items such as NDA reference materials, instrument vans and certain shipping containers are included because they are important adjuncts to optimum utilization of safeguards instrumentation. This catalog does not include devices for physical protection. As was the case with its predecessor, most of the material in this catalog originated in the US and Canada; a few contributions came from member states of the European Community

  17. Post-implementation review of inadequate core cooling instrumentation

    International Nuclear Information System (INIS)

    Anderson, J.L.; Anderson, R.L.; Hagen, E.W.; Morelock, T.C.; Huang, T.L.; Phillips, L.E.

    1988-01-01

    Studies of Three Mile Island (TMI) accident identified the need for additional instrumentation to detect inadequate core cooling (ICC) in nuclear power plants. Industry studies by plant owners and reactor vendors supported the conclusion that improvements were needed to help operators diagnose the approach to or existence of ICC and to provide more complete information for operator control of safety injection, flow to minimize the consequences of such an accident. In 1980, the US Nuclear Regulatory Commission (NRC) required further studies by the industry and described ICC instrumentation design requirements that included human factors and environmental considerations. On December 10, 1982, NRC issued to Babcock and Wilcox (BandW) licensees' orders for Modification of License and transmitted to all pressurized water reactor (PWR) licensees Generic Letter 82-28 to inform them of the revised NRC requirements. The instrumentation requirements for detection of ICC include upgraded subcooling margin monitors (SMMs), upgraded core exit thermocouples (CETs), and installation of a reactor coolant inventory tracking system (RCITS)

  18. Safeguards instrumentation: a computer-based catalog. Second edition

    Energy Technology Data Exchange (ETDEWEB)

    Auerbach, C.

    1985-04-01

    This catalog contains entries on new developments and on items listed in BNL 51450, which have either been carried over unchanged or been updated. More than 70 entries were deleted because of either obsolescence, insufficient interest in terms of safeguards, or lack of documentable development activities in recent years. Some old listings as well as new material was consolidated into more generic entries. As in the earlier document, the emphasis is on devices and instruments that are either in field use at this time or under active development. A few items such as NDA reference materials, instrument vans and certain shipping containers are included because they are important adjuncts to optimum utilization of safeguards instrumentation. This catalog does not include devices for physical protection. As was the case with its predecessor, most of the material in this catalog originated in the US and Canada; a few contributions came from member states of the European Community.

  19. Nuclear reactor instrumentation

    International Nuclear Information System (INIS)

    Duncombe, E.; McGonigal, G.

    1975-01-01

    A liquid metal cooled nuclear reactor is described which has an equal number of fuel sub-assemblies and sensing instruments. Each instrument senses temperature and rate of coolant flow of a coolant derived from a group of three sub-assemblies so that an abnormal value for one sub-assembly will be indicated on three instruments thereby providing for redundancy of up to two of the three instruments. The abnormal value may be a precurser to unstable boiling of coolant

  20. Development of an instrument for the evaluation of advanced life support performance.

    Science.gov (United States)

    Peltonen, L-M; Peltonen, V; Salanterä, S; Tommila, M

    2017-10-01

    Assessing advanced life support (ALS) competence requires validated instruments. Existing instruments include aspects of technical skills (TS), non-technical skills (NTS) or both, but one instrument for detailed assessment that suits all resuscitation situations is lacking. This study aimed to develop an instrument for the evaluation of the overall ALS performance of the whole team. This instrument development study had four phases. First, we reviewed literature and resuscitation guidelines to explore items to include in the instrument. Thereafter, we interviewed resuscitation team professionals (n = 66), using the critical incident technique, to determine possible additional aspects associated with the performance of ALS. Second, we developed an instrument based on the findings. Third, we used an expert panel (n = 20) to assess the validity of the developed instrument. Finally, we revised the instrument based on the experts' comments and tested it with six experts who evaluated 22 video recorded resuscitations. The final version of the developed instrument had 69 items divided into adherence to guidelines (28 items), clinical decision-making (5 items), workload management (12 items), team behaviour (8 items), information management (6 items), patient integrity and consideration of laymen (4 items) and work routines (6 items). The Cronbach's α values were good, and strong correlations between the overall performance and the instrument were observed. The instrument may be useful for detailed assessment of the team's overall performance, but the numerous items make the use demanding. The instrument is still under development, and more research is needed to determine its psychometric properties. © 2017 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  1. An instrument for X-ray set quality assurance measurements

    International Nuclear Information System (INIS)

    Willetts, R.J.; West, M.B.; Brydon, J.

    1989-01-01

    This paper describes a prototype electronic instrument for performing quality assurance (QA) measurements on diagnostic radiological equipment with a view to long-term performance assessment on a Regional basis. The instrument is based on a Tandy 200 laptop computer and has been developed primarily to include the assessment of image intensifier/TV systems in a general QA package. It is capable of accepting signals from the following sources: (1) a radiation detector (diode array); (2) a Keithley kV divider (Keithley Instruments, Inc.); (3) the video output of an image intensifier system. (author)

  2. Legal Instruments of Regulation of Development of Banking Activity in Ukraine

    Directory of Open Access Journals (Sweden)

    Senyshch Pavlo M.

    2014-03-01

    Full Text Available The article considers main approaches to identification of essence of legal instruments of regulation of development of the banking activity, identifies the mechanism of legal regulation of the banking activity and its elements and justifies the system and form of legal regulation of the banking activity in Ukraine. It describes subjects of legal regulation of the banking activity at the international level, which are the Basel Committee on Banking Supervision, European Central Bank, IMF, International Financial Reporting Standards Foundation and others. The article considers specific features of the regulatory requirements of Basel II and Basel III and specific features of their introduction into the banking activity. It describes anti-cyclic measures offered by the Basel Committee, which should facilitate formation of such conditions, under which the banking sector could have a lower level of leverage and stability with respect to influence of system risks. Significant attention is paid to international instruments of regulation of the banking activity, which include the following legal acts: Uniform Rules for Collections, Uniform Customs and Practice for Documentary Credits, and Unified Rules for Loan Guarantees. The article shows that the share of subordinate legal acts is significant in the Ukrainian system of banking regulatory and legal acts since the state cannot operatively react to the changing processes in banking at the legislative level and, that is why, basic provisions on carrying out banking activity should be fixed in law.

  3. Astronomical Instruments in India

    Science.gov (United States)

    Sarma, Sreeramula Rajeswara

    The earliest astronomical instruments used in India were the gnomon and the water clock. In the early seventh century, Brahmagupta described ten types of instruments, which were adopted by all subsequent writers with minor modifications. Contact with Islamic astronomy in the second millennium AD led to a radical change. Sanskrit texts began to lay emphasis on the importance of observational instruments. Exclusive texts on instruments were composed. Islamic instruments like the astrolabe were adopted and some new types of instruments were developed. Production and use of these traditional instruments continued, along with the cultivation of traditional astronomy, up to the end of the nineteenth century.

  4. [Spinal instrumentation, source of progress, but also revealing pitfalls].

    Science.gov (United States)

    Dubousset, Jean

    2003-01-01

    , indication for cosmesis extend widely including adults. But also because these adult peoples are asking more and more for an active way of life including often sports. The indications for function also extend requiring more and more pre operative checking to limit the increase of the risk.--At the level of the pre operative strategy, most surgeons were establishing the strategy looking only on more or less close similar cases already done. In fact no personalized strategy done on biomechanical static and dynamic data of the patient as well as its connective and bone tissue proper qualities were really performed. It is why it is still now difficult to know pre operatively the behavior of the not fused area above and mainly below the instrumented area. Because the power of correction was very much improved with the new instruments, we can get some 3D imbalance immediately after or secondary acquired after such surgery as well from anterior or posterior devices. It is why we need pre operative simulation of surgery thanks to the computer.--At the level of surgery itself: it is not entered in the practical field any per operative 3D reliable measurement to know exactly the surgeon is doing because the maximum of reduction is not the optimum for many cases and this has to be quantified. The last thing is of course the difficulty to translate the lying position of the patient during surgery to the standing functional one. Some answers or perspectives for the future may come from:--The real pre operative simulation of the surgery (including levels of instrumentation amount of correction in 3D) according to the personalized values, stiffness, quality of soft tissues, weight, size, of the patient, localization and type of the deformity, etc.... Computer software already exists or are on the way to be expanded.--Per operative 3D control of what is doing the surgeon are also emerging with real time information in order to adjust the correction according to the pre op. simulation. In

  5. Determination of elemental levels in radiopharmaceuticals by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Capote Rodriguez, Gil; Guevara, Sergio Ribeiro; Arribere, Maria; Hernandez Rivero, Tulio

    2001-01-01

    Neutron Activation Analysis (NAA) both Instrumental (INAA) and Radiochemical (RNAA) have been extensively applied to the determination of minor and trace elements in samples of quite different origin and composition. Particularly, the analysis of microquantities of toxic elements in biological samples by INAA and RNAA is extensively reported. NAA has been also applied to the determination of minor and trace constituents in biomedical products. The use of the INAA in pharmaceutical samples has not been reported yet. This could be due in some extent because of the specificity of these types of samples, and also because of the need to irradiate the samples in a nuclear reactor. The objective of the present work was to study the feasibility of applying INAA for the quantification of minor and trace constituents in three radiopharmaceuticals. The formulation of these products was elaborated by the Isotope Center and proposed for registration to the corresponding authorities. The active components of three radiopharmaceuticals were analyzed: Hexamethylene propylene Amino oxine (HMPAO), Dimercaptosuccinic Acid (DMSA) and Diethylenetriamine penta-acetic Acid (DTPA). The samples were dried up to constant weight at room temperature. In order to avoid possible interferences from the irradiated polyethylene vials, the samples were pressed into the form of pills using a die of stainless steel. The weights of the samples ranged from 50 mg to 200 mg. Samples in duplicates were irradiated in the 0.5 k W Bariloche RA-6 Research Nuclear Reactor. To induce more (n,gamma) reactions and therefore increase the number of analytes and also to minimize interferences from activation products, the irradiation was carried out using two regimens. For the measurement, irradiated pills were put into clean polyethylene containers. The measurements were carried out with a 67 cm 3 ORTEC HPGe intrinsic-N coaxial detector with a resolution of 2.0 keV FWHM at 1.33 MeV and with an efficiency of 12

  6. Preliminary thermal architecture of the X-IFU instrument dewar

    Science.gov (United States)

    Charles, Ivan; Daniel, Christophe; André, Jérome; Duband, Lionel; Duval, Jean-Marc; den Hartog, Roland; Mitsuda, Kazuhisa; Shinozaki, Keisuke; van Weers, Henk; Yamasaki, Noriko Y.

    2016-07-01

    The ESA Athena mission will implement 2 instruments to study the hot and energetic universe. The X-ray Integral Field Unit (X-IFU) will provide spatially resolved high resolution spectroscopy. This high energy resolution of 2.5 eV at 7 keV could be achieved thanks to TES (Transition Edge Sensor) detectors that need to be cooled to very low temperature. To obtain the required 50 mK temperature level, a careful design of the cryostat and of the cooling chain including different technologies in cascade is needed. The preliminary cryogenic architecture of the X-IFU instrument that fulfils the TES detector thermal requirements is described. In particular, the thermal design of the detector focal plane assembly (FPA), that uses three temperature stages (from 2 K to 50 mK) to limit the thermal loads on the lowest temperature stage, is described. The baseline cooling chain is based on European and Japanese mechanical coolers (Stirling, Pulse tube and Joule Thomson coolers) that precool a sub Kelvin cooler made of a 3He sorption cooler coupled with a small ADR (Adiabatic Demagnetization Refrigerator). Preliminary thermal budgets of the X-IFU cryostat are presented and discussed regarding cooling chain performances.

  7. Fibre Channel Instrumentation Environment Profile (IEP). Version 0.8

    National Research Council Canada - National Science Library

    Jones, Sid

    1999-01-01

    .... Since this document is focused at the system level, the target audience is both the end-item designer concerned about interoperability and the instrumentation engineer concerned with understanding...

  8. Modularized Parallel Neutron Instrument Simulation on the TeraGrid

    International Nuclear Information System (INIS)

    Chen, Meili; Cobb, John W.; Hagen, Mark E.; Miller, Stephen D.; Lynch, Vickie E.

    2007-01-01

    In order to build a bridge between the TeraGrid (TG), a national scale cyberinfrastructure resource, and neutron science, the Neutron Science TeraGrid Gateway (NSTG) is focused on introducing productive HPC usage to the neutron science community, primarily the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). Monte Carlo simulations are used as a powerful tool for instrument design and optimization at SNS. One of the successful efforts of a collaboration team composed of NSTG HPC experts and SNS instrument scientists is the development of a software facility named PSoNI, Parallelizing Simulations of Neutron Instruments. Parallelizing the traditional serial instrument simulation on TeraGrid resources, PSoNI quickly computes full instrument simulation at sufficient statistical levels in instrument de-sign. Upon SNS successful commissioning, to the end of 2007, three out of five commissioned instruments in SNS target station will be available for initial users. Advanced instrument study, proposal feasibility evaluation, and experiment planning are on the immediate schedule of SNS, which pose further requirements such as flexibility and high runtime efficiency on fast instrument simulation. PSoNI has been redesigned to meet the new challenges and a preliminary version is developed on TeraGrid. This paper explores the motivation and goals of the new design, and the improved software structure. Further, it describes the realized new features seen from MPI parallelized McStas running high resolution design simulations of the SEQUOIA and BSS instruments at SNS. A discussion regarding future work, which is targeted to do fast simulation for automated experiment adjustment and comparing models to data in analysis, is also presented

  9. Using the Rasch measurement model to design a report writing assessment instrument.

    Science.gov (United States)

    Carlson, Wayne R

    2013-01-01

    This paper describes how the Rasch measurement model was used to develop an assessment instrument designed to measure student ability to write law enforcement incident and investigative reports. The ability to write reports is a requirement of all law enforcement recruits in the state of Michigan and is a part of the state's mandatory basic training curriculum, which is promulgated by the Michigan Commission on Law Enforcement Standards (MCOLES). Recently, MCOLES conducted research to modernize its training and testing in the area of report writing. A structured validation process was used, which included: a) an examination of the job tasks of a patrol officer, b) input from content experts, c) a review of the professional research, and d) the creation of an instrument to measure student competency. The Rasch model addressed several measurement principles that were central to construct validity, which were particularly useful for assessing student performances. Based on the results of the report writing validation project, the state established a legitimate connectivity between the report writing standard and the essential job functions of a patrol officer in Michigan. The project also produced an authentic instrument for measuring minimum levels of report writing competency, which generated results that are valid for inferences of student ability. Ultimately, the state of Michigan must ensure the safety of its citizens by licensing only those patrol officers who possess a minimum level of core competency. Maintaining the validity and reliability of both the training and testing processes can ensure that the system for producing such candidates functions as intended.

  10. Instrumentation a reader

    CERN Document Server

    Pope, P

    1990-01-01

    This book contains a selection of papers and articles in instrumentation previously pub­ lished in technical periodicals and journals of learned societies. Our selection has been made to illustrate aspects of current practice and applications of instrumentation. The book does not attempt to be encyclopaedic in its coverage of the subject, but to provide some examples of general transduction techniques, of the sensing of particular measurands, of components of instrumentation systems and of instrumentation practice in two very different environments, the food industry and the nuclear power industry. We have made the selection particularly to provide papers appropriate to the study of the Open University course T292 Instrumentation. The papers have been chosen so that the book covers a wide spectrum of instrumentation techniques. Because of this, the book should be of value not only to students of instrumen­ tation, but also to practising engineers and scientists wishing to glean ideas from areas of instrumen...

  11. Vibration test report on the instrumented capsule for fuel irradiation test

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jeong Soo; Yoon, D. B.; Wu, J. S.; Oh, J. M.; Park, S. J.; Cho, M. S.; Kim, B. G.; Kang, Y. W

    2003-01-01

    The fluid-induced vibration level of instrumented capsule, which was manufactured for fuel irradiation test at the reactor core of HANARO, was investigated. For this purpose, the instrumented capsule was loaded at the OR site of the HANARO design verification test facility that could simulate identical flow condition as the HANARO core. Then, vibration signals of the instrumented capsule subjected to various flow conditions were measured by using vibration sensors. In time domain analysis, maximum amplitudes and RMS values of the measured acceleration and displacement signals were obtained. By using frequency domain analysis, frequency components of the fluid-induced vibration were analyzed. In addition, natural frequencies of the instrumented capsule were obtained by performing modal test. The frequency analysis results showed that the natural frequency components near 7.5Hz and 17.5Hz were dominant in the fluid-induced vibration signal. The maximum amplitude of the accelerations was measured as 12.04m/s{sup 2} that is within the allowable vibrational limit(18.99m/s{sup 2})of the reactor structure. Also, the maximum displacement amplitude was calculated as 0.191mm. Since these vibration levels are remarkably low, excessive vibration is not expected when the irradiation test of the instrumented capsule is performed at the HANARO core.

  12. Effect of Instrumentation Length and Instrumentation Systems: Hand Versus Rotary Files on Apical Crack Formation - An In vitro Study.

    Science.gov (United States)

    Devale, Madhuri R; Mahesh, M C; Bhandary, Shreetha

    2017-01-01

    WL-1 (p=0.057 for RaCe files and p=0.087 for K3 files). There was no statistical significance between stainless steel hand files and rotary files in terms of crack formation. Instrumentation length had a significant effect on the formation of cracks when rotary files were used. Using rotary instruments 1 mm short of apical foramen caused lesser crack formation. But, there was no statistically significant difference in number of cracks formed with hand files at two instrumentation levels.

  13. Increased incidence of pseudarthrosis after unilateral instrumented transforaminal lumbar interbody fusion in patients with lumbar spondylosis: Clinical article.

    Science.gov (United States)

    Gologorsky, Yakov; Skovrlj, Branko; Steinberger, Jeremy; Moore, Max; Arginteanu, Marc; Moore, Frank; Steinberger, Alfred

    2014-10-01

    Transforaminal lumbar interbody fusion (TLIF) with segmental pedicular instrumentation is a well established procedure used to treat lumbar spondylosis with or without spondylolisthesis. Available biomechanical and clinical studies that compared unilateral and bilateral constructs have produced conflicting data regarding patient outcomes and hardware complications. A prospective cohort study was undertaken by a group of neurosurgeons. They prospectively enrolled 80 patients into either bilateral or unilateral pedicle screw instrumentation groups (40 patients/group). Demographic data collected for each group included sex, age, body mass index, tobacco use, and Workers' Compensation/litigation status. Operative data included segments operated on, number of levels involved, estimated blood loss, length of hospital stay, and perioperative complications. Long-term outcomes (hardware malfunction, wound dehiscence, and pseudarthrosis) were recorded. For all patients, preoperative baseline and 6-month postoperative scores for Medical Outcomes 36-Item Short Form Health Survey (SF-36) outcomes were recorded. Patient follow-up times ranged from 37 to 63 months (mean 52 months). No patients were lost to follow-up. The patients who underwent unilateral pedicle screw instrumentation (unilateral cohort) were slightly younger than those who underwent bilateral pedicle screw instrumentation (bilateral cohort) (mean age 42 vs. 47 years, respectively; p = 0.02). No other significant differences were detected between cohorts with regard to demographic data, mean number of lumbar levels operated on, or distribution of the levels operated on. Estimated blood loss was higher for patients in the bilateral cohort, but length of stay was similar for patients in both cohorts. The incidence of pseudarthrosis was significantly higher among patients in the unilateral cohort (7 patients [17.5%]) than among those in the bilateral cohort (1 patient [2.5%]) (p = 0.02). Wound dehiscence occurred for

  14. Nuclear electronic instrumentation

    International Nuclear Information System (INIS)

    Ramirez J, F. J.

    2010-01-01

    The activities carried out in the Instituto Nacional de Investigaciones Nucleares (ININ) in the field of the nuclear electronic instrumentation included those activities corresponding to the design and production of nuclear instruments in a first stage, as well as the internal activities of design, repair and maintenance that have supported to other projects of the institution during many years. It is mentioned of the presence and constant collaboration of the ININ with the IAEA in different projects and programs. Also, it is mentioned on the establishment of the Radiation Detectors Laboratory, which for their characteristics and repair capacities of radiation detectors of cooled semiconductor, it is only in their specialty. It is emphasized the investigation and the development in the field of new radiation detectors and applications, as well as the important contribution in this field, in institutions like: Mexican Petroleum, National Commission of Nuclear Safety and Safeguards and Federal Commission of Electricity. Finally a position of the future of these activities is made, considering the speed of the advances of the electronic and nuclear technology. (Author)

  15. Instrumentation for Power System Disturbance Monitoring, Data ...

    African Journals Online (AJOL)

    In this paper, the level of instrumentation for power system disturbance monitoring, data acquisition and control in Nigerian Electric Power System; National Electric Power Authority (NEPA) is presented. The need for accurate power system disturbance monitoring is highlighted. A feature of an adequate monitoring, data ...

  16. Reconstruction of instrumentation and control system (SKR)

    International Nuclear Information System (INIS)

    Wiening, K.-H.

    2001-01-01

    For the first time extensive upgrades have been performed in all safety related areas of units with WWER 440/230 reactors. One of the most important actions was the replacement of the safety and safety related instrumentation and control. The state of the art digital safety instrumentation and control system TELEPERM XS has been implemented in units 1 and 2 of the Bohunice V1 power plant. The requirements as deduced from safety assessments conducted by commissions of international experts have been fulfilled, so that Bohunice V1 after this gradual reconstruction has been upgraded to an internationally accepted safety level for the remainder of its service life. (author)

  17. Assessing the body image: relevance, application and instruments for oncological settings.

    Science.gov (United States)

    Annunziata, Maria Antonietta; Giovannini, Lorena; Muzzatti, Barbara

    2012-05-01

    Body image is the sum of physical, cognitive, emotional, and relational elements that, when integrated, allow the development of a whole, healthy self-identity. Even though body image is normally studied in relation to eating disorders, it can also be influenced by other pathologies, including cancer. In oncology, an effective body image assessment is fundamental. The physical effects of cancer and cancer treatments are important and frequently irreversible also on a functional and emotional level; however, only few surveys have investigated body image in this peculiar context. An extensive literature review was carried out in PubMed and PsycINFO. We considered articles published from 1990 to 2010. Two hundred sixty-three papers matched the search criteria. Assessment methodologies included clinical interviews, self-report measures, questionnaires, symptom check lists, and graphic tests and projective techniques. After excluding the instruments that referred to eating disorders, validated only for adolescents, and/or projective and graphic tests, we found 81 articles with six questionnaires specifically dedicated to body image assessment in oncology. From our systematic review, we could identify six instruments specifically designed for assessing body image in the oncological area. In this paper, we discuss their general characteristics, psychometrics properties and the clinical implications, and body image relevance on the quality of life in cancer patients.

  18. Nuclear instrumentation for research reactors; Instrumentacion nuclear para reactores nucleares de investigacion

    Energy Technology Data Exchange (ETDEWEB)

    Hofer, Carlos G.; Pita, Antonio; Verrastro, Claudio A.; Maino, Eduardo J. [Comision Nacional de Energia Atomica, Buenos Aires (Argentina). Unidad de Actividades de Reactores y Centrales Nucleares. Sector Instrumentacion y Control

    1997-10-01

    The nuclear instrumentation for research reactors in Argentina was developed in 70`. A gradual modernization of all the nuclear instrumentation is planned. It includes start-up and power range instrumentation, as well as field monitors, clamp, scram and rod movement control logic. The new instrumentation is linked to a computer network, based on real time operating system for data acquisition, display and logging. This paper describes the modules and whole system aspects. (author). 2 refs.

  19. A Study on Site Selecting for National Project including High Level Radioactive Waste Disposal

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kilyoo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Many national projects are stopped since sites for the projects are not determined. The sites selections are hold by NIMBY for unpleasant facilities or by PYMFY for preferable facilities among local governments. The followings are the typical ones; NIMBY projects: high level radioactive waste disposal, THAAD, Nuclear power plant(NPP), etc. PIMFY projects: South-east new airport, KTX station, Research center for NPP decommission, etc. The site selection for high level radioactive waste disposal is more difficult problem, and thus government did not decide and postpone to a dead end street. Since it seems that there is no solution for site selection for high level radioactive waste disposal due to NIMBY among local governments, a solution method is proposed in this paper. To decide a high level radioactive waste disposal, the first step is to invite a bid by suggesting a package deal including PIMFY projects such as Research Center for NPP decommission. Maybe potential host local governments are asked to submit sealed bids indicating the minimum compensation sum that they would accept the high level radioactive waste disposal site. If there are more than one local government put in a bid, then decide an adequate site by considering both the accumulated PESS point and technical evaluation results. By considering how fairly preferable national projects and unpleasant national projects are distributed among local government, sites selection for NIMBY or PIMFY facilities is suggested. For NIMBY national projects, risk, cost benefit analysis is useful and required since it generates cost value to be used in the PESS. For many cases, the suggested method may be not adequate. However, similar one should be prepared, and be basis to decide sites for NIMBY or PIMFY national projects.

  20. Musical Instrument-Associated Health Issues and Their Management.

    Science.gov (United States)

    Okoshi, Kae; Minami, Taro; Kikuchi, Masahiro; Tomizawa, Yasuko

    2017-09-01

    Playing musical instruments can bring joy to people, but can also cause a wide variety of health issues that range from mild disorders to potentially fatal conditions. Although sports medicine is an established medical subspecialty, relatively few studies have investigated the health issues associated with musical instruments. Here we present an overview of these health issues. These include infections due to microorganisms, allergic reactions, as well as mechanical injuries from sustained high pressures within the oral, mediastinal, thoracic, and abdominal cavities. For example, wind instruments can potentially harbor thousands of pathogenic organisms. If several players share the same instrument, these instruments present potential hazards in the spread of infections. A fatal case of hypersensitivity pneumonitis in a bagpiper is particularly noteworthy. Similarly, a case of gastrointestinal anthrax in an animal-hide drummer is a reminder of this rare but highly fatal disease. Although not fatal, hearing-related disorders, neuromuscular issues, musculoskeletal problems, and contact dermatitis are also very common among instrumentalists. This review aims to illuminate these under-recognized health issues by highlighting both the common conditions and the rare but fatal cases.

  1. Health Promotion Behaviours and Level of Activities of Daily Living and Instrumental Activities of Daily Living Among Elderly People in West Region of Tehran: A Cross-Sectional Survey

    Directory of Open Access Journals (Sweden)

    Aghil Habibi Sola

    2007-10-01

    Full Text Available Objectives: As individuals live longer, health promotion behaviors get even more important, particularly with regard to maintaining functional independence and improving quality of life. The purpose of this study was to explore the relationship between health promotion behaviors and level of Activities of Daily Living (ADL and Instrumental Activities of Daily Living (IADL among elderly people in west region of Tehran. Methods & Materials: This was a descriptive-correlational study. A multi-stage sample of 410 community residents who were over 60 years old were selected from west region of Tehran. Participants who consented to participate in the study were interviewed with a structured questionnaire. The questionnaire consisted of 2-part; Health Promotion Behavior Checklist and questions related to status of physical functioning, which includes activities of daily living (ADLs and instrumental activities of daily living (IADLs. Descriptive statistics and T-test were used to data analysis. Results: The results of the study showed that there were significant relations between ADLs and ' exercise or walking', 'drinking milk, eating dairy and meat', 'eating vegetables and fruits', 'low salt diet' and 'low fat diet' (P<0.05. Furthermore there were significant relations between the IADLs and 'smoking cessation', 'alcohol abstinence', 'exercise or walking', 'drinking milk, eating dairy and meat', 'eating vegetables and fruits', 'low salt diet' and 'low fat diet' (P<0.05. Conclusion: Study showed, health promotion behaviors and level of ADL and IADL are related meaningfully. Health care professionals should enhance the physical functioning in elderly people by facilitating health promotion behaviors through formal health promotion programs which focus on regular diet, exercise, and regular physical check-ups which will maintain and increase a healthy and active life.

  2. Instrumentation qualification. Seismic qualification of C-E instrumentation equipment. Part One

    International Nuclear Information System (INIS)

    1977-05-01

    A summary of the C-E seismic qualification program utilized to demonstrate the seismic design adequacy of the instrumentation and control equipment used in C-E supplied Nuclear Steam Supply Systems (NSSS) is presented. The report is divided into two parts. Part One includes the equipment seismic requirements and a description of the qualification methods. Part Two lists the specific equipment by nuclear station in which it is used and the equipment test results are summarized in a standard data sheet format to facilitate review. The seismic requirements are based on individual contract commitments with C-E customers and the NRC Standard Review Plan, Section 3.10 ''Seismic Qualification of Category I Instrumentation and Electrical Equipment.'' Equipment is qualified for use in a seismic environment where damage potential to the equipment is less than or equal to that simulated seismic environment to which it has been qualified. The anticipated Safe Shutdown Earthquake (SSE) environment at the inservice location of equipment should be confirmed by each applicant as not exceeding that to which it is qualified

  3. Geosciences research: development of techniques and instruments for investigation geological environments

    International Nuclear Information System (INIS)

    1993-01-01

    In order to understand the geological environment in Japan, new investigation techniques have been developed. These include: 1) Geological techniques for fracture characterization, 2) Nondestructive investigation techniques for detailed geological structure, 3) Instruments for hydraulic characterization, 4) Instruments for hydrochemical characterization. Results so far obtained are: 1) Fractures can be classified by their patterns, 2) The applicability and limitations of conventional geophysical methods were defined, 3) Instruments for measuring very low permeability were successfully developed, 4) Instruments for sampling formation water without changing in-situ conditions were developed. (author)

  4. IOT Overview: IR Instruments

    Science.gov (United States)

    Mason, E.

    In this instrument review chapter the calibration plans of ESO IR instruments are presented and briefly reviewed focusing, in particular, on the case of ISAAC, which has been the first IR instrument at VLT and whose calibration plan served as prototype for the coming instruments.

  5. Examination of a clinical teaching effectiveness instrument used for summative faculty assessment.

    Science.gov (United States)

    Bierer, S Beth; Hull, Alan L

    2007-12-01

    This study explores whether a clinical teaching effectiveness (CTE) instrument provides valid scores for summative faculty assessment. The sample included all CTE instruments (n = 10,087) that learners (N = 1,194) completed to assess clinical teachers (N = 872) during 1 academic year. The authors investigated response processes (e.g., missing data, straight-line responses, level of learner), internal structure (e.g., confirmatory and exploratory factor analysis), teaching ratings by learner group (medical student or resident), and relation to other variables (e.g., correlation with global rating). Response processes identified a high prevalence of straight-line responses (same rating across all items) and differential patterns of missing data by learner group. Medical students rated their teachers higher than residents, and CTE scores had different factor structures depending on learner group. High correlation coefficients of CTE items with a single rating of overall teaching performance suggest that learners consider global performance when assessing clinical teaching performance.

  6. The compatibility of flexible instruments under the Kyoto Protocol

    International Nuclear Information System (INIS)

    Jepma, C.J.; Van der Gaast, W.P.; Woerdman, E.

    1998-01-01

    The compatibility of the Kyoto Protocol flexible instruments and the lessons that can be learned form the AIJ-phase (AIJ stands for Activities Implemented Jointly) are discussed. The key point to be made is that there may be various applications of flexible instruments which can create situations where the various instruments would crowd out each other. On the other hand, applying flexible instruments may create a leverage for Parties in terms of achieving domestic environmental objectives. In addition, several issues related to the implementation of Joint Implementation (JI) , Clean Development Mechanism (CDM) and international emissions trading are discussed. The issues concern mainly those that have been included in the working programme on flexible instruments for CoP4 and CoP5 (CoP stands for Convention of Parties). As such the report discusses the consequences of possible negotiations outcomes at CoP for the effectiveness of flexible instruments, Parties' capabilities to achieve their Kyoto Protocol commitments cost-effectively, and the role of the private sector on the national and international credits markets(s). 106 refs

  7. Thermo Scientific Ozone Analyzer Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Springston, S. R. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-03-01

    The primary measurement output from the Thermo Scientific Ozone Analyzer is the concentration of the analyte (O3) reported at 1-s resolution in units of ppbv in ambient air. Note that because of internal pneumatic switching limitations the instrument only makes an independent measurement every 4 seconds. Thus, the same concentration number is repeated roughly 4 times at the uniform, monotonic 1-s time base used in the AOS systems. Accompanying instrument outputs include sample temperatures, flows, chamber pressure, lamp intensities and a multiplicity of housekeeping information. There is also a field for operator comments made at any time while data is being collected.

  8. Design and validation of a standards-based science teacher efficacy instrument

    Science.gov (United States)

    Kerr, Patricia Reda

    National standards for K--12 science education address all aspects of science education, with their main emphasis on curriculum---both science subject matter and the process involved in doing science. Standards for science teacher education programs have been developing along a parallel plane, as is self-efficacy research involving classroom teachers. Generally, studies about efficacy have been dichotomous---basing the theoretical underpinnings on the work of either Rotter's Locus of Control theory or on Bandura's explanations of efficacy beliefs and outcome expectancy. This study brings all three threads together---K--12 science standards, teacher education standards, and efficacy beliefs---in an instrument designed to measure science teacher efficacy with items based on identified critical attributes of standards-based science teaching and learning. Based on Bandura's explanation of efficacy being task-specific and having outcome expectancy, a developmental, systematic progression from standards-based strategies and activities to tasks to critical attributes was used to craft items for a standards-based science teacher efficacy instrument. Demographic questions related to school characteristics, teacher characteristics, preservice background, science teaching experience, and post-certification professional development were included in the instrument. The instrument was completed by 102 middle level science teachers, with complete data for 87 teachers. A principal components analysis of the science teachers' responses to the instrument resulted in two components: Standards-Based Science Teacher Efficacy: Beliefs About Teaching (BAT, reliability = .92) and Standards-Based Science Teacher Efficacy: Beliefs About Student Achievement (BASA, reliability = .82). Variables that were characteristic of professional development activities, science content preparation, and school environment were identified as members of the sets of variables predicting the BAT and BASA

  9. Improvements and Revamping of In-Core Instrumentation Systems

    International Nuclear Information System (INIS)

    Garam, Eric De

    1993-01-01

    The results of the improvements done by Fumarate Tia in these domains are really satisfying and it is clear that the problems of leakage existing in the old units on the thermocouples sealing systems and on the seal table of the income instrumentation, cannot exist on the French Units or on the units equipped with Fumarate Tia equipment. At the same time, all the equipment which constitute the Income instrumentation have been improved with the aim of reliability and safety. The equipment used to perform maintenance activities has also been improved to both reduce doses and increase efficiency. The purpose of this paper is to describe the principal improvements and revamping of income instrumentation systems, and to summarize the principal lessons learned from our experience on all designs of PWR. Fumarate Tia, is permanently looking for improving the existing systems of instrumentation with the aim of reduction of the dosimetry during the maintenance services, improvement of the liability and lifetime of the equipment, and of course reduction of the duration of the outages in keeping always the same level of quality

  10. Troubleshooting in nuclear instruments

    International Nuclear Information System (INIS)

    1987-06-01

    This report on troubleshooting of nuclear instruments is the product of several scientists and engineers, who are closely associated with nuclear instrumentation and with the IAEA activities in the field. The text covers the following topics: Preamplifiers, amplifiers, scalers, timers, ratemeters, multichannel analyzers, dedicated instruments, tools, instruments, accessories, components, skills, interfaces, power supplies, preventive maintenance, troubleshooting in systems, radiation detectors. The troubleshooting and repair of instruments is illustrated by some real examples

  11. Instrumentation for status monitoring and protection of SST-1 superconducting magnets

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, A.N., E-mail: aashoo.sharma@yahoo.com; Prasad, U.; Doshi, K.; Varmora, P.; Khristi, Y.; Patel, D.; Pradhan, S.

    2016-11-15

    Highlights: • Details of status monitoring instrumentation are presented. • Protection instrumentation details are presented. • Instrumentation installation details, signal conditioning and DAQ system details and the results during SST-1 operation are presented. - Abstract: Superconducting magnets of SST-1 are extensively instrumented to continuously monitor the health of magnets during machine cool-down, plasma experiments and also during the machine warm-up phase. These instrumentations include temperature sensors, flow meters, hall probes, strain gages, displacement sensors, pressure sensors and voltage taps. The number of sensors and their locations has been optimized to systematically monitor all important magnet parameters to ensure its safety. In-house developed modular signal conditioning cards have been developed for these instrumentations. The data is acquired on a Versa Module Europa bus based data acquisition system (VME DAQ). This paper gives an overview of selection, installation, laboratory scale validations, and distribution logics of these instrumentations. Results during plasma campaigns and the up-gradation aspects of these instrumentations are also discussed in this paper.

  12. Low-voltage Power Supply Subsystem for a Sub-Orbital Particle Physic Instrument

    Directory of Open Access Journals (Sweden)

    Hector Hugo Silva Lopez

    2014-01-01

    Full Text Available The Japanese Experiment Module–Extreme Universe Space Observatory (JEM-EUSO is a wide-field (+/-~30°of aperture 2.5m refractor telescope to be installed in the International Space Station (ISS. The instrument looks downward from its orbit, into Earth’s atmosphere, with the main objective of observing ultra-violet (UV fluorescence light generated by Ultra-High Energy Cosmic Rays (UHECR extensive air showers (EAS. It is a frontier particle-physics experiment, the first of its kind. The validation of the technical readiness level of such a complex and unique instrument requires prototypes at several levels of integration. At the highest level, the EUSO-Balloon instrument has been conceived, through French space agency (CNES. At a smaller scale and in suborbital flight, EUSO-Balloon integrates all the sub-systems of the full space JEM-EUSO telescope, allowing end-to-end testing of hardware and interfaces, and to probing the global detection chain and strategy, while improving at the same time our knowledge of atmospheric and terrestrial UV background. EUSO-Balloon will be flown by CNES for the first time from Timmins, Canada; on spring 2014.This article presents the low-voltage power supply (LVPS subsystem development for the EUSO-Balloon instrument. This LVPS is the fully operational prototype for the space instrument JEM-EUSO. Besides design and construction, all performance tests and integration results with the other involved subsystems are shown.

  13. Development of a pressurizer level compensator for use on N Reactor

    International Nuclear Information System (INIS)

    Bussell, J.H.

    1985-07-01

    The instrument described in this report has been developed to compensate the measured water level in the N Reactor pressurizer for temperature effects. N Reactor is a pressurized water nuclear reactor (PWR). The instrument is defined as a pressurizer level compensator (PLC). A pressurizer is used in a PWR to control the primary coolant pressure and provide a surge volume for primary coolant expansion and contraction. A means of compensating for water and steam density is required because of the wide range of pressure and temperature that result from different steady state and transient reactor power levels. The uncompensated level is determined by measurement of differential pressure between the top of the level measurement zone and the bottom of the level measurement zone. Temperature of the water in the pressurizer is the parameter that is used to determine the proper level compensation since water and steam density are primarily functions of temperature in this case. The PLC uses a microprocessor to calculate the compensated level from temperature and differential pressure measurements. This report includes a description of the design, development, and implementation of software and hardware that are in the PLC. 9 refs., 51 figs., 17 tabs

  14. Construction Of Critical Thinking Skills Test Instrument Related The Concept On Sound Wave

    Science.gov (United States)

    Mabruroh, F.; Suhandi, A.

    2017-02-01

    This study aimed to construct test instrument of critical thinking skills of high school students related the concept on sound wave. This research using a mixed methods with sequential exploratory design, consists of: 1) a preliminary study; 2) design and review of test instruments. The form of test instruments in essay questions, consist of 18 questions that was divided into 5 indicators and 8 sub-indicators of the critical thinking skills expressed by Ennis, with questions that are qualitative and contextual. Phases of preliminary study include: a) policy studies; b) survey to the school; c) and literature studies. Phases of the design and review of test instruments consist of two steps, namely a draft design of test instruments include: a) analysis of the depth of teaching materials; b) the selection of indicators and sub-indicators of critical thinking skills; c) analysis of indicators and sub-indicators of critical thinking skills; d) implementation of indicators and sub-indicators of critical thinking skills; and e) making the descriptions about the test instrument. In the next phase of the review test instruments, consist of: a) writing about the test instrument; b) validity test by experts; and c) revision of test instruments based on the validator.

  15. MGR COMPLIANCE PROGRAM GUIDANCE PACKAGE FOR RADIATION PROTECTION EQUIPMENT, INSTRUMENTATION, AND FACILITIES

    International Nuclear Information System (INIS)

    2000-01-01

    This Compliance Program Guidance Package identifies the regulatory guidance and industry codes and standards addressing radiation protection equipment, instrumentation, and support facilities considered to be appropriate for radiation protection at the Monitored Geologic Repository (MGR). Included are considerations relevant to radiation monitoring instruments, calibration, contamination control and decontamination, respiratory protection equipment, and general radiation protection facilities. The scope of this Guidance Package does not include design guidance relevant to criticality monitoring, area radiation monitoring, effluent monitoring, and airborne radioactivity monitoring systems since they are considered to be the topics of specific design and construction requirements (i.e., ''fixed'' or ''built-in'' systems). This Guidance Package does not address radiation protection design issues; it addresses the selection and calibration of radiation monitoring instrumentation to the extent that the guidance is relevant to the operational radiation protection program. Radon and radon progeny monitoring instrumentation is not included in the Guidance Package since such naturally occurring radioactive materials do not fall within the NRC's jurisdiction at the MGR

  16. Assessing medical professionalism: A systematic review of instruments and their measurement properties

    Science.gov (United States)

    Li, Honghe; Liu, Yang; Wen, Deliang

    2017-01-01

    Background Over the last three decades, various instruments were developed and employed to assess medical professionalism, but their measurement properties have yet to be fully evaluated. This study aimed to systematically evaluate these instruments’ measurement properties and the methodological quality of their related studies within a universally acceptable standardized framework and then provide corresponding recommendations. Methods A systematic search of the electronic databases PubMed, Web of Science, and PsycINFO was conducted to collect studies published from 1990–2015. After screening titles, abstracts, and full texts for eligibility, the articles included in this study were classified according to their respective instrument’s usage. A two-phase assessment was conducted: 1) methodological quality was assessed by following the COnsensus-based Standards for the selection of health status Measurement INstruments (COSMIN) checklist; and 2) the quality of measurement properties was assessed according to Terwee’s criteria. Results were integrated using best-evidence synthesis to look for recommendable instruments. Results After screening 2,959 records, 74 instruments from 80 existing studies were included. The overall methodological quality of these studies was unsatisfactory, with reasons including but not limited to unknown missing data, inadequate sample sizes, and vague hypotheses. Content validity, cross-cultural validity, and criterion validity were either unreported or negative ratings in most studies. Based on best-evidence synthesis, three instruments were recommended: Hisar’s instrument for nursing students, Nurse Practitioners’ Roles and Competencies Scale, and Perceived Faculty Competency Inventory. Conclusion Although instruments measuring medical professionalism are diverse, only a limited number of studies were methodologically sound. Future studies should give priority to systematically improving the performance of existing

  17. Instrument hardware and software upgrades at IPNS

    International Nuclear Information System (INIS)

    Worlton, Thomas; Hammonds, John; Mikkelson, D.; Mikkelson, Ruth; Porter, Rodney; Tao, Julian; Chatterjee, Alok

    2006-01-01

    IPNS is in the process of upgrading their time-of-flight neutron scattering instruments with improved hardware and software. The hardware upgrades include replacing old VAX Qbus and Multibus-based data acquisition systems with new systems based on VXI and VME. Hardware upgrades also include expanded detector banks and new detector electronics. Old VAX Fortran-based data acquisition and analysis software is being replaced with new software as part of the ISAW project. ISAW is written in Java for ease of development and portability, and is now used routinely for data visualization, reduction, and analysis on all upgraded instruments. ISAW provides the ability to process and visualize the data from thousands of detector pixels, each having thousands of time channels. These operations can be done interactively through a familiar graphical user interface or automatically through simple scripts. Scripts and operators provided by end users are automatically included in the ISAW menu structure, along with those distributed with ISAW, when the application is started

  18. Falsification Testing of Instrumental Variables Methods for Comparative Effectiveness Research.

    Science.gov (United States)

    Pizer, Steven D

    2016-04-01

    To demonstrate how falsification tests can be used to evaluate instrumental variables methods applicable to a wide variety of comparative effectiveness research questions. Brief conceptual review of instrumental variables and falsification testing principles and techniques accompanied by an empirical application. Sample STATA code related to the empirical application is provided in the Appendix. Comparative long-term risks of sulfonylureas and thiazolidinediones for management of type 2 diabetes. Outcomes include mortality and hospitalization for an ambulatory care-sensitive condition. Prescribing pattern variations are used as instrumental variables. Falsification testing is an easily computed and powerful way to evaluate the validity of the key assumption underlying instrumental variables analysis. If falsification tests are used, instrumental variables techniques can help answer a multitude of important clinical questions. © Health Research and Educational Trust.

  19. Tactile feedback is an effective instrument for the training of grasping with a prosthesis at low- and medium-force levels.

    Science.gov (United States)

    De Nunzio, Alessandro Marco; Dosen, Strahinja; Lemling, Sabrina; Markovic, Marko; Schweisfurth, Meike Annika; Ge, Nan; Graimann, Bernhard; Falla, Deborah; Farina, Dario

    2017-08-01

    Grasping is a complex task routinely performed in an anticipatory (feedforward) manner, where sensory feedback is responsible for learning and updating the internal model of grasp dynamics. This study aims at evaluating whether providing a proportional tactile force feedback during the myoelectric control of a prosthesis facilitates learning a stable internal model of the prosthesis force control. Ten able-bodied subjects controlled a sensorized myoelectric prosthesis performing four blocks of consecutive grasps at three levels of target force (30, 50, and 70%), repeatedly closing the fully opened hand. In the first and third block, the subjects received tactile and visual feedback, respectively, while during the second and fourth block, the feedback was removed. The subjects also performed an additional block with no feedback 1 day after the training (Retest). The median and interquartile range of the generated forces was computed to assess the accuracy and precision of force control. The results demonstrated that the feedback was indeed an effective instrument for the training of prosthesis control. After the training, the subjects were still able to accurately generate the desired force for the low and medium target (30 and 50% of maximum force available in a prosthesis), despite the feedback being removed within the session and during the retest (low target force). However, the training was substantially less successful for high forces (70% of prosthesis maximum force), where subjects exhibited a substantial loss of accuracy as soon as the feedback was removed. The precision of control decreased with higher forces and it was consistent across conditions, determined by an intrinsic variability of repeated myoelectric grasping. This study demonstrated that the subject could rely on the tactile feedback to adjust the motor command to the prosthesis across trials. The subjects adjusted the mean level of muscle activation (accuracy), whereas the precision could not

  20. Calibration through on-line monitoring of instruments channels

    International Nuclear Information System (INIS)

    James, R.W.

    1996-01-01

    Plant technical specifications require periodic calibration of instrument channels, and this has traditionally meant calibration at fixed time intervals for nearly all instruments. Experience has shown that unnecessarily frequent calibrations reduce channel availability and reliability, impact outage durations, and increase maintenance costs. An alternative approach to satisfying existing requirements for periodic calibration consists of on-line monitoring and quantitative comparison of instrument channels during operation to identify instrument degradation and failure. A Utility Working Group has been formed by EPRI to support the technical activities necessary to achieve generic NRC acceptance of on-line monitoring of redundant instrument channels as a basis for determining when to perform calibrations. A topical report proposing NRC acceptance of this approach was submitted in August 1995, and the Working Group is currently resolving NRC technical questions. This paper describes the proposed approach and the current status of the topical report with regard to NRC review. While these activities will not preclude utilities from continuing to use existing calibration approaches, successful acceptance of this performance-based approach will allow utilities to substantially reduce the number of calibrations which are performed. Concurrent benefits will include reduced I ampersand C impact on outage durations and improved sensitivity to instrument channel performance

  1. Instrumentation and operational plan for geokinetics retort No. 22

    Energy Technology Data Exchange (ETDEWEB)

    Parrish, R.L.; Hommert, P.J.

    1980-04-01

    This report outlines the general plan for the instrumentation and technical direction of a horizontal in siti retorting experiment to be conducted at the Geokinetics, Inc. field site in Uintah County, Utah. Bed preparation has been accomplished by Geokinetics by blasting the retort zone with explosives emplaced in wells drilled from the surface. Downhole instrumentation will consist of approx. 300 thermocouples and 28 combustion gas sampling ports to monitor the movement of the reaction front during the retorting process. Surface instrumentation will provide measurements of flow rates, gas composition, liquid products and other process parameters to monitor the overall operation of the process. The operational plan includes provision for data interpretation and real time material balance calculations in the field, including an evaluation of the effect on processing rates and oil yield due to the use of recycled combusted off gases and changes in rate of injection of inlet gases.

  2. Instruments to assess self-care among healthy children: A systematic review of measurement properties.

    Science.gov (United States)

    Urpí-Fernández, Ana-María; Zabaleta-Del-Olmo, Edurne; Montes-Hidalgo, Javier; Tomás-Sábado, Joaquín; Roldán-Merino, Juan-Francisco; Lluch-Canut, María-Teresa

    2017-12-01

    To identify, critically appraise and summarize the measurement properties of instruments to assess self-care in healthy children. Assessing self-care is a proper consideration for nursing practice and nursing research. No systematic review summarizes instruments of measurement validated in healthy children. Psychometric review in accordance with the COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) panel. MEDLINE, CINAHL, PsycINFO, Web of Science and Open Grey were searched from their inception to December 2016. Validation studies with a healthy child population were included. Search was not restricted by language. Two reviewers independently assessed the methodological quality of included studies using the COSMIN checklist. Eleven studies were included in the review assessing the measurement properties of ten instruments. There was a maximum of two studies per instrument. None of the studies evaluated the properties of test-retest reliability, measurement error, criterion validity and responsiveness. Internal consistency and structural validity were rated as "excellent" or "good" in four studies. Four studies were rated as "excellent" in content validity. Cross-cultural validity was rated as "poor" in the two studies (three instruments) which cultural adaptation was carried out. The evidence available does not allow firm conclusions about the instruments identified in terms of reliability and validity. Future research should focus on generate evidence about a wider range of measurement properties of these instruments using a rigorous methodology, as well as instrument testing on different countries and child population. © 2017 John Wiley & Sons Ltd.

  3. Level monitoring system with pulsating sensor—Application to online level monitoring of dashpots in a fast breeder reactor

    Energy Technology Data Exchange (ETDEWEB)

    Malathi, N.; Sahoo, P., E-mail: sahoop@igcar.gov.in; Ananthanarayanan, R.; Murali, N. [Real Time Systems Division, Electronics, Instrumentation and Radiological Safety Group, Indira Gandhi Centre for Atomic Research, Kalpakkam 603102 (India)

    2015-02-15

    An innovative continuous type liquid level monitoring system constructed by using a new class of sensor, viz., pulsating sensor, is presented. This device is of industrial grade and it is exclusively used for level monitoring of any non conducting liquid. This instrument of unique design is suitable for high resolution online monitoring of oil level in dashpots of a sodium-cooled fast breeder reactor. The sensing probe is of capacitance type robust probe consisting of a number of rectangular mirror polished stainless steel (SS-304) plates separated with uniform gaps. The performance of this novel instrument has been thoroughly investigated. The precision, sensitivity, response time, and the lowest detection limit in measurement using this device are <0.01 mm, ∼100 Hz/mm, ∼1 s, and ∼0.03 mm, respectively. The influence of temperature on liquid level is studied and the temperature compensation is provided in the instrument. The instrument qualified all recommended tests, such as environmental, electromagnetic interference and electromagnetic compatibility, and seismic tests prior to its deployment in nuclear reactor. With the evolution of this level measurement approach, it is possible to provide dashpot oil level sensors in fast breeder reactor for the first time for continuous measurement of oil level in dashpots of Control and Safety Rod Drive Mechanism during reactor operation.

  4. CT evaluation of canal preparation using rotary and hand NI-TI instruments: An in vitro study

    Science.gov (United States)

    Nagaraja, Shruthi; Sreenivasa Murthy, B V

    2010-01-01

    Background: Controlled, uniformly tapered radicular preparation is a great challenge in endodontics. Improper preparation can lead to procedural errors like transportation of foramen, uneven dentine thickness, stripping of root canal, formation of ledge, zip, and elbow in curved canals. These procedural errors and their sequel can adversely affect the prognosis of treatment. Aim/Objectives: The present in vitro study aims to evaluate canal preparation based on the following factors: canal transportation, remaining dentine thickness and comparing centering ability between hand Ni-Ti K files and ProTaper rotary Ni-Ti instruments using computed tomography (CT). Materials and Methods: For evaluation, 30 mesiobuccal roots of maxillary molars were selected. Of these, 15 roots were distributed into two groups where Group 1 included hand instrumentation with Ni-Ti K-files; and Group 2 comprised ProTaper NiTi rotary system. Pre instrumentation and post instrumentation three-dimensional CT images were obtained from root cross-sections that were 1 mm thick from apex to the canal orifice; scanned images were then superimposed and compared. Result: It was observed that the manual technique using hand Ni-Ti K-file produced lesser canal transportation and maintained greater dentine thickness than the rotary ProTaper technique at middle and coronal third and this difference was statistically significant. No significant difference was seen with regard to canal transportation and remaining root dentine at apical levels. With regard to centering ratio, no significant difference was seen between both the groups at all levels. Conclusion: ProTaper should be used judiciously, especially in curved canals, as it causes higher canal transportation and thinning of root dentine at middle and coronal levels. None of the groups showed optimal centering ability. PMID:20582214

  5. Mobile Instruments Measure Atmospheric Pollutants

    Science.gov (United States)

    2009-01-01

    As a part of NASA's active research of the Earth s atmosphere, which has included missions such as the Atmospheric Laboratory of Applications and Science (ATLAS, launched in 1992) and the Total Ozone Mapping Spectrometer (TOMS, launched on the Earth Probe satellite in 1996), the Agency also performs ground-based air pollution research. The ability to measure trace amounts of airborne pollutants precisely and quickly is important for determining natural patterns and human effects on global warming and air pollution, but until recent advances in field-grade spectroscopic instrumentation, this rapid, accurate data collection was limited and extremely difficult. In order to understand causes of climate change and airborne pollution, NASA has supported the development of compact, low power, rapid response instruments operating in the mid-infrared "molecular fingerprint" portion of the electromagnetic spectrum. These instruments, which measure atmospheric trace gases and airborne particles, can be deployed in mobile laboratories - customized ground vehicles, typically - to map distributions of pollutants in real time. The instruments must be rugged enough to operate rapidly and accurately, despite frequent jostling that can misalign, damage, or disconnect sensitive components. By measuring quickly while moving through an environment, a mobile laboratory can correlate data and geographic points, revealing patterns in the environment s pollutants. Rapid pollutant measurements also enable direct determination of pollutant sources and sinks (mechanisms that remove greenhouse gases and pollutants), providing information critical to understanding and managing atmospheric greenhouse gas and air pollutant concentrations.

  6. Electronic instrument for radon daughter dosimetry. Report of investigations

    International Nuclear Information System (INIS)

    Durkin, J.

    1977-01-01

    Due to the daily exposures of uranium mining personnel to 222Rn daughters, a device is needed which will continually monitor the individual's exposure. Such a device has been built and tested and is known as the Radon Daughter Dosimeter. This is an electronic instrument using a solid-state detector and circuitry. The system permits the evaluation of cumulative exposures to airborne radon progeny, expressed in units of Working Level Hours (WL-HRS). The instrument is a personal device worn by the individual throughout the working shift. Since the instrument is in close proximity to the miner and measures continual exposure, it provides an accurate account of total cumulative exposure, thus avoiding the errors caused by the present technique of spot checking of the environment

  7. Radioactive standards and calibration methods for contamination monitoring instruments

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Makoto [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1997-06-01

    Contamination monitoring in the facilities for handling unsealed radioactive materials is one of the most important procedures for radiation protection as well as radiation dose monitoring. For implementation of the proper contamination monitoring, radiation measuring instruments should not only be suitable to the purpose of monitoring, but also be well calibrated for the objective qualities of measurement. In the calibration of contamination monitoring instruments, quality reference activities need to be used. They are supplied in different such as extended sources, radioactive solutions or radioactive gases. These reference activities must be traceable to the national standards or equivalent standards. On the other hand, the appropriate calibration methods must be applied for each type of contamination monitoring instruments. In this paper, the concepts of calibration for contamination monitoring instruments, reference sources, determination methods of reference quantities and practical calibration methods of contamination monitoring instruments, including the procedures carried out in Japan Atomic Energy Research Institute and some relevant experimental data. (G.K.)

  8. Cost-effective design of economic instruments in nutrition policy

    Directory of Open Access Journals (Sweden)

    Smed Sinne

    2007-04-01

    Full Text Available Abstract This paper addresses the potential for using economic regulation, e.g. taxes or subsidies, as instruments to combat the increasing problems of inappropriate diets, leading to health problems such as obesity, diabetes 2, cardiovascular diseases etc. in most countries. Such policy measures may be considered as alternatives or supplements to other regulation instruments, including information campaigns, bans or enhancement of technological solutions to the problems of obesity or related diseases. 7 different food tax and subsidy instruments or combinations of instruments are analysed quantitatively. The analyses demonstrate that the average cost-effectiveness with regard to changing the intake of selected nutritional variables can be improved by 10–30 per cent if taxes/subsidies are targeted against these nutrients, compared with targeting selected food categories. Finally, the paper raises a range of issues, which need to be investigated further, before firm conclusions about the suitability of economic instruments in nutrition policy can be drawn.

  9. Penetrating eye injuries from writing instruments

    Directory of Open Access Journals (Sweden)

    Kelly SP

    2011-12-01

    Full Text Available Simon P Kelly, Graham MB ReevesThe Royal Bolton Hospital, Bolton, UKPurpose: To consider the potential for ocular injury from writing implements by presenting four such cases, and to consider the incidence of such eye injuries from analysis of a national trauma database.Methods: The Home and Leisure Accident Surveillance System was searched for records of eye injuries from writing instruments to provide UK estimates of such injuries. Four patients with ocular penetrating injury from pens or pencils (especially when caused by children, and examined by the authors, are described which illustrate mechanisms of injury.Results: It is estimated that around 748 ocular pen injuries and 892 ocular pencil injuries of undetermined severity occurred annually in the UK during the database surveillance period 2000–2002. No eye injuries from swords, including toy swords and fencing foils, were reported.Conclusion: Ocular perforation sometimes occur from writing instruments that are thrown in the community, especially by children. Implications for policy and prevention are discussed. Non-specialists should have a low threshold for referring patients with eye injuries if suspicious of ocular penetration, even where caused by everyday objects, such as writing instruments.Keywords: eye injury, eye, children, mechanism, writing instruments, prevention

  10. Instrumentation

    International Nuclear Information System (INIS)

    Muehllehner, G.; Colsher, J.G.

    1982-01-01

    This chapter reviews the parameters which are important to positron-imaging instruments. It summarizes the options which various groups have explored in designing tomographs and the methods which have been developed to overcome some of the limitations inherent in the technique as well as in present instruments. The chapter is not presented as a defense of positron imaging versus single-photon or other imaging modality, neither does it contain a description of various existing instruments, but rather stresses their common properties and problems. Design parameters which are considered are resolution, sampling requirements, sensitivity, methods of eliminating scattered radiation, random coincidences and attenuation. The implementation of these parameters is considered, with special reference to sampling, choice of detector material, detector ring diameter and shielding and variations in point spread function. Quantitation problems discussed are normalization, and attenuation and random corrections. Present developments mentioned are noise reduction through time-of-flight-assisted tomography and signal to noise improvements through high intrinsic resolution. Extensive bibliography. (U.K.)

  11. Instrument calls and real-time code for laboratory automation

    International Nuclear Information System (INIS)

    Taber, L.; Ames, H.S.; Yamauchi, R.K.; Barton, G.W. Jr.

    1978-01-01

    These programs are the result of a joint Lawrence Livermore Laboratory and Environmental Protection Agency project to automate water quality laboratories. They form the interface between the analytical instruments and the BASIC language programs for data reduction and analysis. They operate on Data General NOVA 840's at Cincinnati and Chicago and on a Data General ECLIPSE C330 at Livermore. The operating system consists of unmodified RDOS, Data General's disk operating system, and Data General's multiuser BASIC modified to provide the instrument CALLs and other functions described. Instruments automated at various laboratories include Technicon AutoAnalyzers, atomic absorption spectrophotometers, total organic carbon analyzers, an emission spectrometer, an electronic balance, sample changers, and an optical spectrophotometer. Other instruments may be automated using these same CALLs, or new CALLs may be written as described

  12. Solar Energy Research Center Instrumentation Facility

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Thomas, J.; Papanikolas, John, P.

    2011-11-11

    DEVICE FABRICATION LABORATORY DEVELOPMENT The space allocated for this laboratory was shell space that required an upfit in order to accommodate nano-fabrication equipment in a quasi-clean room environment. This construction project (cost $279,736) met the non-federal cost share requirement of $250,000 for this award. The central element of the fabrication laboratory is a new $400,000+ stand-alone system, funded by other sources, for fabricating and characterizing photovoltaic devices, in a state-of-the-art nanofabrication environment. This congressionally directed project also included the purchase of an energy dispersive x-ray analysis (EDX) detector for a pre-existing transmission electron microscope (TEM). This detector allows elemental analysis and elemental mapping of materials used to fabricate solar energy devices which is a key priority for our research center. TASK 2: SOLAR ENERGY SPECTROSCOPY LABORATORY DEVELOPMENT (INSTRUMENTATION) This laboratory provides access to modern spectroscopy and photolysis instrumentation for characterizing devices, materials and components on time scales ranging from femtoseconds to seconds and for elucidating mechanisms. The goals of this congressionally directed project included the purchase and installation of spectroscopy and photolysis instrumentation that would substantially and meaningfully enhance the capabilities of this laboratory. Some changes were made to the list of equipment proposed in the original budget. These changes did not represent a change in scope, approach or aims of this project. All of the capabilities and experiments represented in the original budget were maintained. The outcome of this Congressionally Directed Project has been the development of world-class fabrication and spectroscopy user facilities for solar fuels research at UNC-CH. This award has provided a significant augmentation of our pre-existing instrumentation capabilities which were funded by earlier UNC SERC projects, including the Energy

  13. Effect of Instrumentation Length and Instrumentation Systems: Hand Versus Rotary Files on Apical Crack Formation – An In vitro Study

    Science.gov (United States)

    Mahesh, MC; Bhandary, Shreetha

    2017-01-01

    significantly more number of cracks were seen at WL than WL-1 (p=0.057 for RaCe files and p=0.087 for K3 files). Conclusion There was no statistical significance between stainless steel hand files and rotary files in terms of crack formation. Instrumentation length had a significant effect on the formation of cracks when rotary files were used. Using rotary instruments 1 mm short of apical foramen caused lesser crack formation. But, there was no statistically significant difference in number of cracks formed with hand files at two instrumentation levels. PMID:28274036

  14. Policy instruments for energy conservation and environmental policy in the Netherlands

    Energy Technology Data Exchange (ETDEWEB)

    Bovenberg, A.L. [Tinbergen Inst., Rotterdam (Netherlands)

    1992-03-01

    In this paper it is assumed that the policy objective is not so much to economize on energy as to reduce pollution. In particular, to curb the emissions of carbon dioxide. A number of environmental policy instruments pertaining to fossil fuels are analyzed, mainly in the context of the Dutch economy: regulation, subsidies, voluntary agreements with industry, and taxation. At the moment, most industrial countries, including the Netherlands, rely almost entirely on the first three instruments. More recently, however, there has been a growing interest in environmental taxation. The theory that taxation is always and everywhere the best instrument assumes, however, perfect markets and a closed economy. Most economies, including the Dutch one, are riddled with market imperfections. Hence, policy makers confront a second best case. This implies that in selecting policy instruments, they have to resort to a more pragmatic `case-by-case` approach. A diversified diet is advocated. Taxation is part of that diet. Section 2 explores a number of important advantages of the tax instrument. Section 3 discusses a number of problems if a small open economy like the Netherlands would unilaterally adopt such a tax, especially if that tax would include energy-intensive firms that are subject to international competition. In this connection, some alternative policy instruments are analyzed in Section 4. Section 5 proceeds by investigating the case of international coordination and explores the conditions under which coordinated taxes could be successful. Section 6 analyzes policies targeted at households and at firms that are not subject to international competition. 13 refs.

  15. 77 FR 66178 - Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting...

    Science.gov (United States)

    2012-11-02

    ... DEPARTMENT OF COMMERCE Bureau of Industry and Security Sensors and Instrumentation Technical Advisory Committee; Notice of Partially Closed Meeting; Rescheduled The Sensors and Instrumentation... that affect the level of export controls applicable to sensors [[Page 66179

  16. Examining item content and structure in health status and health outcomes instruments: toward the development of a grammar for better understanding of the concepts being measured.

    Science.gov (United States)

    Erickson, Pennifer; Willke, Richard J

    2013-06-01

    Health outcomes instruments assess diverse health concepts. Although item-level concepts are considered fundamental elements, the field lacks structures for evaluating and organizing them for decision making. This article proposes a grammar using item stems, response options, and recall periods to systematically identify item-level concepts. The grammar uses "core concept," "evaluative component," and "recall period" as intuitive terms for communicating with stakeholders. Better characterization of concepts is necessary for classifying instrument content and linking it to treatment benefit. Items in 2 generic and 21 disease-specific instruments were evaluated to develop and illustrate the use of the grammar. Concepts were assigned International Classification of Functioning, Disability and Health codes for exploring the value that the grammar and a classification system add to the understanding of content across instruments. The 23 instruments include many core concepts; emotional function is the only concept assessed in all instruments. Concepts in disease-specific instruments show obvious patterns; for example, arthritis instruments focus on physical function. The majority of instruments used the same response options across all items, with five-point scales being the most common. Most instruments used one recall period for all items. Shorter recall periods were used for conditions associated with "flares," such as chronic obstructive pulmonary disease and "skin disease." Every diagnosis, however, showed variation across instruments in the recall period used. This analysis indicates the proposed grammar's potential for discerning the conceptual content within and between health outcomes instruments and illustrates its value for improving communication between stakeholders and for making decisions related to treatment benefit. Copyright © 2013 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  17. Medical instruments and devices principles and practices

    CERN Document Server

    Schreiner, Steven; Peterson, Donald R

    2015-01-01

    Medical Instruments and Devices: Principles and Practices originates from the medical instruments and devices section of The Biomedical Engineering Handbook, Fourth Edition. Top experts in the field provide material that spans this wide field. The text examines how biopotential amplifiers help regulate the quality and content of measured signals. It includes instruments and devices that span a range of physiological systems and the physiological scale: molecular, cellular, organ, and system. The book chronicles the evolution of pacemakers and their system operation and discusses oscillometry, cardiac output measurement, and the direct and indirect methods of measuring cardiac output. The authors also expound on the mechanics and safety of defibrillators and cover implantable stimulators, respiration, and the structure and function of mechanical ventilators. In addition, this text covers in depth: Anesthesia Delivery Electrosurgical Units and Devices Biomedical Lasers Measuring Cellular Traction Forces Blood G...

  18. Influence of NiTi alloy on the root canal shaping capabilities of the ProTaper Universal and ProTaper Gold rotary instrument systems

    Directory of Open Access Journals (Sweden)

    Jussaro Alves DUQUE

    Full Text Available Abstract Objective This study aimed to evaluate the influence of the NiTi wire in Conventional NiTi (ProTaper Universal PTU and Controlled Memory NiTi (ProTaper Gold PTG instrument systems on the quality of root canal preparation. Material and Methods Twelve mandibular molars with separate mesial canals were scanned using a high-definition microcomputed tomography system. The PTU and PTG instruments were used to shape twelve mesial canals each. The canals were scanned after preparation with F2 and F3 instruments of the PTU and PTG systems. The analyzed parameters included the remaining dentin thickness at the apical and cervical levels, root canal volume and untouched canal walls. Data was analyzed for statistical significance by the Friedman and Dunn’s tests. For the comparison of data between groups, the Mann-Whitney test was used. Results In the pre-operative analysis, there were no statistically significant differences between the groups in terms of the area and volume of root canals (P>.05. There was also no statistically significant difference between the systems with respect to root canal volume after use of the F2 and F3 instruments. There was no statistical difference in the dentin thickness at the first apical level between, before and after instrumentation for both systems. At the 3 cervical levels, the PTG maintained centralization of the preparation on the transition between the F2 and F3 instruments, which did not occur with the PTU. Conclusion The Conventional NiTi (PTU and Controlled Memory NiTi (PTG instruments displayed comparable capabilities for shaping the straight mesial root canals of mandibular molars, although the PTG was better than the PTU at maintaining the centralization of the shape in the cervical portion.

  19. Influence of NiTi alloy on the root canal shaping capabilities of the ProTaper Universal and ProTaper Gold rotary instrument systems

    Science.gov (United States)

    DUQUE, Jussaro Alves; VIVAN, Rodrigo Ricci; CAVENAGO, Bruno Cavalini; AMOROSO-SILVA, Pablo Andrés; BERNARDES, Ricardo Affonso; de VASCONCELOS, Bruno Carvalho; DUARTE, Marco Antonio Hungaro

    2017-01-01

    Abstract Objective This study aimed to evaluate the influence of the NiTi wire in Conventional NiTi (ProTaper Universal PTU) and Controlled Memory NiTi (ProTaper Gold PTG) instrument systems on the quality of root canal preparation. Material and Methods Twelve mandibular molars with separate mesial canals were scanned using a high-definition microcomputed tomography system. The PTU and PTG instruments were used to shape twelve mesial canals each. The canals were scanned after preparation with F2 and F3 instruments of the PTU and PTG systems. The analyzed parameters included the remaining dentin thickness at the apical and cervical levels, root canal volume and untouched canal walls. Data was analyzed for statistical significance by the Friedman and Dunn’s tests. For the comparison of data between groups, the Mann-Whitney test was used. Results In the pre-operative analysis, there were no statistically significant differences between the groups in terms of the area and volume of root canals (P>.05). There was also no statistically significant difference between the systems with respect to root canal volume after use of the F2 and F3 instruments. There was no statistical difference in the dentin thickness at the first apical level between, before and after instrumentation for both systems. At the 3 cervical levels, the PTG maintained centralization of the preparation on the transition between the F2 and F3 instruments, which did not occur with the PTU. Conclusion The Conventional NiTi (PTU) and Controlled Memory NiTi (PTG) instruments displayed comparable capabilities for shaping the straight mesial root canals of mandibular molars, although the PTG was better than the PTU at maintaining the centralization of the shape in the cervical portion. PMID:28198973

  20. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1984-09-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  1. Problems with radiological surveillance instrumentation

    International Nuclear Information System (INIS)

    Swinth, K.L.; Tanner, J.E.; Fleming, D.M.

    1985-01-01

    Many radiological surveillance instruments are in use at DOE facilities throughout the country. These instruments are an essential part of all health physics programs, and poor instrument performance can increase program costs or compromise program effectiveness. Generic data from simple tests on newly purchased instruments shows that many instruments will not meet requirements due to manufacturing defects. In other cases, lack of consideration of instrument use has resulted in poor acceptance of instruments and poor reliability. The performance of instruments is highly variable for electronic and mechanical performance, radiation response, susceptibility to interferences and response to environmental factors. Poor instrument performance in these areas can lead to errors or poor accuracy in measurements

  2. Proceedings of the International topical meeting on VVER instrumentation and control

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-12-31

    The Proceedings contain the full texts of 44 contributions, out of which 42 have been input to INIS. The papers cover various aspects of WWER instrumentation and control including reactor upgrading and modernization, testing and refurbishment of instrumentation, and operational experience and problems. (A.K.).

  3. Proceedings of the International topical meeting on VVER instrumentation and control

    International Nuclear Information System (INIS)

    1997-11-01

    The Proceedings contain the full texts of 44 contributions, out of which 42 have been input to INIS. The papers cover various aspects of WWER instrumentation and control including reactor upgrading and modernization, testing and refurbishment of instrumentation, and operational experience and problems. (A.K.)

  4. Problems and Instruments of Product and Technological Diversification of Manufacturing

    Directory of Open Access Journals (Sweden)

    Kuzmin Oleg Ye.

    2015-03-01

    Full Text Available The purpose of the article involves identification of objectives and development of instruments for product and technological diversification aimed at updating the range of products and introducing innovative technologies, which will ensure a high level of competitiveness and create preconditions for steady development of the enterprise. As a result of studying the literary sources the objectives and instruments for development of enterprises by means of product and technological diversification have been defined. The article suggests effective instruments of product and technological diversification of manufacturing, namely: the model of expansion of the product range, multi-criteria model of optimization of the product range, a modified model of Kantorovich-Koopmans for implementing new production technologies with set limits on the product output. Further research relate to formation of instruments for manufacturing diversification by means of introducing new types of production.

  5. The relationship between the INTERMED patient complexity instrument and Level of Care Utilisation System (LOCUS).

    Science.gov (United States)

    Thurber, Steven; Wilson, Ann; Realmuto, George; Specker, Sheila

    2018-03-01

    To investigate the concurrent and criterion validity of two independently developed measurement instruments, INTERMED and LOCUS, designed to improve the treatment and clinical management of patients with complex symptom manifestations. Participants (N = 66) were selected from hospital records based on the complexity of presenting symptoms, with tripartite diagnoses across biological, psychiatric and addiction domains. Biopsychosocial information from hospital records were submitted to INTERMED and LOCUS grids. In addition, Global Assessment of Functioning (GAF) ratings were gathered for statistical analyses. The product moment correlation between INTERMED and LOCUS was 0.609 (p = .01). Inverse zero-order correlations for INTERMED and LOCUS total score and GAF were obtained. However, only the beta weight for LOCUS and GAF was significant. An exploratory principal components analysis further illuminated areas of convergence between the instruments. INTERMED and LOCUS demonstrated shared variance. INTERMED appeared more sensitive to complex medical conditions and severe physiological reactions, whereas LOCUS findings are more strongly related to psychiatric symptoms. Implications are discussed.

  6. Evaluation of Sensor Configurations for Robotic Surgical Instruments.

    Science.gov (United States)

    Gómez-de-Gabriel, Jesús M; Harwin, William

    2015-10-27

    Designing surgical instruments for robotic-assisted minimally-invasive surgery (RAMIS) is challenging due to constraints on the number and type of sensors imposed by considerations such as space or the need for sterilization. A new method for evaluating the usability of virtual teleoperated surgical instruments based on virtual sensors is presented. This method uses virtual prototyping of the surgical instrument with a dual physical interaction, which allows testing of different sensor configurations in a real environment. Moreover, the proposed approach has been applied to the evaluation of prototypes of a two-finger grasper for lump detection by remote pinching. In this example, the usability of a set of five different sensor configurations, with a different number of force sensors, is evaluated in terms of quantitative and qualitative measures in clinical experiments with 23 volunteers. As a result, the smallest number of force sensors needed in the surgical instrument that ensures the usability of the device can be determined. The details of the experimental setup are also included.

  7. Psychometric evaluation of the Environmental Reality Shock-Related Issues and Concerns instrument for newly graduated nurses.

    Science.gov (United States)

    Kim, Eun-Young; Yeo, Jung Hee; Park, Hyunjeong; Sin, Kyung Mi; Jones, Cheryl B

    2018-02-01

    Reality shock is a critical representation of the gap between nursing education and clinical practice and it is important to explore the level of reality shock among nurses. However, there is no relevant instrument to assess the level of reality shock in South Korea. The purpose of this is to determine the validity and reliability of the Korean version of the Environmental Reality Shock-Related Issues and Concerns instrument. A cross-sectional study design was used in this study. The data collection was conducted in selected 15 hospitals in South Korea. A convenience sample of 216 newly graduated nurses participated in the study. The Korean version of the Environmental Reality Shock-Related Issues and Concerns instrument was developed through the forward-backward translation technique, and revision based on feedback from expert groups. The internal consistency reliability was assessed using Cronbach's alpha, and the construct validity was determined via exploratory and confirmatory factor analysis. The Korean version of the Environmental Reality Shock-Related Issues and Concerns has reliable internal consistency (Cronbach's alpha=0.91). Exploratory factor analysis revealed five factors including job, relationships, expectations, private life, and performance, which explained 61.92% of variance. The factor loadings ranged from 0.451 to 0.832. The five-factor structure was validated by confirmatory factor analysis (RMR0.9). It was concluded that the Korean version of the Environmental Reality Shock-Related Issues and Concerns instrument has satisfactory construct validity and reliability to measure the reality shock of newly graduated nurses in South Korea. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Perceived overprotection, instrumental support and rehabilitation use in elders with vision loss: a longitudinal perspective.

    Science.gov (United States)

    Cimarolli, Verena R; Boerner, Kathrin; Reinhardt, Joann P; Horowitz, Amy

    2013-01-01

    This study's purpose was to investigate changes in perceived overprotection - a problematic aspect of close relationships - over time in relationship to instrumental support receipt and vision rehabilitation service use in a sample of older adults with vision impairment. Participants were 584 older adults with chronic vision impairment who were interviewed three times over a 12-month period. Longitudinal data were analysed using a latent growth curve methodology to examine change over time in perceived overprotection and instrumental support in relation to vision rehabilitation service use. Self-reported levels of overprotection and receipt of instrumental support. Results. Over time perceived overprotection increased but not instrumental support. While perceived overprotection was positively associated with instrumental support initially, over time this relationship did not emerge. Perceived overprotection and instrumental support functioned as predictors of vision rehabilitation hours. However, over time vision rehabilitation service use did not influence these social supports. Perceived overprotection increases over time, yet this change is unaffected by rehabilitation service use and instrumental support. Both family members and elders need to be involved in the vision rehabilitation process and educated about how some level of independence can be regained.

  9. Test instruments used by Journal of Music Therapy authors from 1984-1997.

    Science.gov (United States)

    Gregory, D

    2000-01-01

    Issues of the Journal of Music Therapy from 1984 to 1997 were selected to investigate the application of test instruments in music therapy research. All experimental and descriptive research articles were reviewed to determine if the methodology included test instruments. Other types of measurements-physiological measures, behavioral observations, computerized devices, and self-reports were excluded from the analysis. Test instruments were categorized as either published, unpublished, or researcher-constructed. A test instrument was "published" if, after a search in the "Test Review Locator" of the Buros Mental Measurements Web Site, a reference was found in one or more of the following publications-Mental Measurement Yearbooks, Tests in Print, or Test Critiques. A test was categorized as "unpublished" if the developer was cited in the JMT article but the test was not located in one or more of the above publications. All other test instruments were categorized as researcher-constructed tests designed for the specific study in the article. From 1984-1997, 220 articles were published in JMT. Approximately 83% (n = 183) of the total were experimental or descriptive research studies. Of the 183 articles research studies, 92 (50%) included a test instrument. Reviews of method sections of the 92 articles resulted in a listing of 115 different test instruments. Percentages of researcher-constructed tests, unpublished tests, and published tests were 25%, 35%, and 40% respectively. Lists of tests document the all-encompassing range of client populations and the broad view of human behavior included in the practice of music as therapy. The Journal of Music Therapy, in addition to providing the latest research findings regarding the effectiveness of music as a therapeutic medium, provides an excellent source for updating information about the availability and applicability of test instruments for music therapy clinical practice and training.

  10. USB technique and its application in nuclear instruments

    International Nuclear Information System (INIS)

    Zhou Tong; Wei Yixiang; Wang Yuemin

    2001-01-01

    This paper introduces the technique of communication of USB between computer and collection interface in nuclear instruments. Because Universal Serial Bus has many advantages such as high speed, low energy consuming and Plug and Play. It has been a universal interface of computer. The realization of communication by USB is a step to digital, modularization, and universality of instruments. The mainly content of this paper is the design of circuit and program of the USB intelligent interface, which include how to program a driver and how the software and the hardware interplay with each other. At the end, a testing result in a Multi-Channel Analyzer also is presented. This technique can also be used in other data acquisition instruments

  11. The Diversity of Financial Instruments Traded on the Stock Exchange

    Directory of Open Access Journals (Sweden)

    Iulia-Oana BELCIC-ŞTEFAN

    2015-09-01

    Full Text Available The present study aims to accomplish an in depth analysis of the types of financial instruments traded on the stock exchange, showing in detail both their characteristics and their implications in terms of expected earnings but also the level of associated risk. Depending on the timeframe considered and their own aversion to assumed risk, investors must realize optimal selection of the financial instruments in which they aim to place their funds. Thus, for a long-term investor who does not want to assume a high risk is indicated purchasing bonds, government securities or structured products such as capital protected certificates. If the same long-term investor decides that he can take a higher risk in order to obtain higher gains, he can choose to purchase shares or structured products such as index certificates. The third situation targets investors who seek to obtain short-term gains, but with certain aversion towards the level of assumed risk, for whom is recommended to purchase ETF fund units. At the same time, experienced investors pursuing short-term placement of funds and obtaining substantial gains regardless of the level of risk assumed opt, generally, for structured products such as turbo certificates or derivative financial instruments such futures and options.

  12. The Gem Infrasound Logger and Custom-Built Instrumentation

    International Nuclear Information System (INIS)

    Anderson, Jacob F.; Ronan, Timothy J.

    2017-01-01

    Here, we designed, built, and recorded data with a custom infrasound logger (referred to as the Gem) that is inexpensive, portable, and easy to use. We also describe its design process, qualities, and applications in this article. Field instrumentation is a key element of geophysical data collection, and the quantity and quality of data that can be recorded is determined largely by the characteristics of the instruments used. Geophysicists tend to rely on commercially available instruments, which suffice for many important types of fieldwork. However, commercial instrumentation can fall short in certain roles, which motivates the development of custom sensors and data loggers. Particularly, we found existing data loggers to be expensive and inconvenient for infrasound campaigns, and developed the Gem infrasound logger in response. In this article, we discuss development of this infrasound logger and the various uses found for it, including projects on volcanoes, high-altitude balloons, and rivers. Further, we demonstrate that when needed, scientists can feasibly design and build their own specialized instruments, and that doing so can enable them to record more and better data at a lower cost.

  13. Aquarius: The Instrument and Initial Results

    Science.gov (United States)

    Vine, David M Le; Lagerloef, G.S.E.; Ruf, C.; Wentz, F.; Yueh, S.; Piepmeier, J.; Lindstrom, E.; Dinnat, E.

    2012-01-01

    Aquarius was launched on June 10, 2011 aboard the Aquarius/SAC-D observatory and the instrument has been operating continuously since the initial turned-on was completed on August 25. The initial observed antenna temperatures were close to predicted and the first salinity map was released in September. In order to map the ocean salinity field, Aquarius includes several special features such as the inclusion of a scatterometer to provide a roughness correction, measurement of the third Stokes parameter to correct for Faraday rotation, and fast sampling to mitigate the effects of RFI. This paper provides an overview of the instrument and an example of initial results. Details are covered in subsequent papers in the session on Aquarius

  14. An instrumentation for control and measurement of activated mineral samples

    International Nuclear Information System (INIS)

    Skaarup, P.

    1976-01-01

    A description is given of an instrumentation for control of a pneumatic tube system used to transport mineral samples for activation in a reactor and from there to a detector arrangement. A possible content of uranium in the samples can be seen from the radiation measured. The instrumentation includes a PDP-11 computer and a CAMAC crate

  15. Evaluation of Instrumentation and Dynamic Thermal Ratings for Overhead Lines

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, A. [New York Power Authority, White Plains, NY (United States)

    2013-01-31

    In 2010, a project was initiated through a partnership between the Department of Energy (DOE) and the New York Power Authority (NYPA) to evaluate EPRI's rating technology and instrumentation that can be used to monitor the thermal states of transmission lines and provide the required real-time data for real-time rating calculations. The project included the installation and maintenance of various instruments at three 230 kV line sites in northern New York. The instruments were monitored, and data collection and rating calculations were performed for about a three year period.

  16. The Domain Five Observation Instrument: A Competency-Based Coach Evaluation Tool

    Science.gov (United States)

    Shangraw, Rebecca

    2017-01-01

    The Domain Five Observation Instrument (DFOI) is a competency-based observation instrument recommended for sport leaders or researchers who wish to evaluate coaches' instructional behaviors. The DFOI includes 10 behavior categories and four timed categories that encompass 34 observable instructional benchmarks outlined in domain five of the…

  17. GET: A generic electronics system for TPCs and nuclear physics instrumentation

    Science.gov (United States)

    Pollacco, E. C.; Grinyer, G. F.; Abu-Nimeh, F.; Ahn, T.; Anvar, S.; Arokiaraj, A.; Ayyad, Y.; Baba, H.; Babo, M.; Baron, P.; Bazin, D.; Beceiro-Novo, S.; Belkhiria, C.; Blaizot, M.; Blank, B.; Bradt, J.; Cardella, G.; Carpenter, L.; Ceruti, S.; De Filippo, E.; Delagnes, E.; De Luca, S.; De Witte, H.; Druillole, F.; Duclos, B.; Favela, F.; Fritsch, A.; Giovinazzo, J.; Gueye, C.; Isobe, T.; Hellmuth, P.; Huss, C.; Lachacinski, B.; Laffoley, A. T.; Lebertre, G.; Legeard, L.; Lynch, W. G.; Marchi, T.; Martina, L.; Maugeais, C.; Mittig, W.; Nalpas, L.; Pagano, E. V.; Pancin, J.; Poleshchuk, O.; Pedroza, J. L.; Pibernat, J.; Primault, S.; Raabe, R.; Raine, B.; Rebii, A.; Renaud, M.; Roger, T.; Roussel-Chomaz, P.; Russotto, P.; Saccà, G.; Saillant, F.; Sizun, P.; Suzuki, D.; Swartz, J. A.; Tizon, A.; Usher, N.; Wittwer, G.; Yang, J. C.

    2018-04-01

    General Electronics for TPCs (GET) is a generic, reconfigurable and comprehensive electronics and data-acquisition system for nuclear physics instrumentation of up to 33792 channels. The system consists of a custom-designed ASIC for signal processing, front-end cards that each house 4 ASIC chips and digitize the data in parallel through 12-bit ADCs, concentration boards to read and process the digital data from up to 16 ASICs, a 3-level trigger and master clock module to trigger the system and synchronize the data, as well as all of the associated firmware, communication and data-acquisition software. An overview of the system including its specifications and measured performances are presented.

  18. Safety Research Experiment Facility Project. Conceptual design report. Volume VIII. Instrumentation and control

    International Nuclear Information System (INIS)

    1975-01-01

    Included are sections dealing with the following: nuclear instrumentation system, reactor control system, plant protection system, plant annunciator system, data acquisition system, and reactor cooling system instrumentation and control

  19. Hitting emissions targets with (statistical) confidence in multi-instrument Emissions Trading Schemes

    International Nuclear Information System (INIS)

    Shipworth, David

    2003-12-01

    A means of assessing, monitoring and controlling aggregate emissions from multi-instrument Emissions Trading Schemes is proposed. The approach allows contributions from different instruments with different forms of emissions targets to be integrated. Where Emissions Trading Schemes are helping to meet specific national targets, the approach allows the entry requirements of new participants to be calculated and set at a level that will achieve these targets. The approach is multi-levelled, and may be extended downwards to support pooling of participants within instruments, or upwards to embed Emissions Trading Schemes within a wider suite of policies and measures with hard and soft targets. Aggregate emissions from each instrument are treated stochastically. Emissions from the scheme as a whole are then the joint probability distribution formed by integrating the emissions from its instruments. Because a Bayesian approach is adopted, qualitative and semi-qualitative data from expert opinion can be used where quantitative data is not currently available, or is incomplete. This approach helps government retain sufficient control over emissions trading scheme targets to allow them to meet their emissions reduction obligations, while minimising the need for retrospectively adjusting existing participants' conditions of entry. This maintains participant confidence, while providing the necessary policy levers for good governance

  20. Estimating discharge using multi-level velocity data from acoustic doppler instruments

    DEFF Research Database (Denmark)

    Poulsen, Jane Bang; Rasmussen, Keld Rømer; Ovesen, Niels Bering

    In the majority of Danish streams, weed growth affects the effective stream width and bed roughness thus imposes temporal variations on the stage-discharge relationship. Small stream-gradients and firm ecology based restrictions prevent that hydraulic structures are made at the discharge stations...... increases to more than 3 m. The Doppler instruments (Nortek) are placed on a vertical pole about 2 m off the right bank at three fixed elevations above the streambed (0.3, 0.6, and 1.3 m); the beams point horizontally towards the left bank perpendicularly to the average flow direction. At each depth......, the Doppler sensor records 10 minute average stream velocities in the central 10 m section of the stream. During summer periods with low flow, stream velocity has only been recorded at two depths since the water table drops below the uppermost sensor. A pressure transducer is also placed at the pole where...