WorldWideScience

Sample records for level dependent contrast

  1. Brain magnetic resonance imaging with contrast dependent on blood oxygenation

    International Nuclear Information System (INIS)

    Ogawa, S.; Lee, T.M.; Kay, A.R.; Tank, D.W.

    1990-01-01

    Paramagnetic deoxyhemoglobin in venous blood is a naturally occurring contrast agent for magnetic resonance imaging (MRI). By accentuating the effects of this agent through the use of gradient-echo techniques in high yields, the authors demonstrate in vivo images of brain microvasculature with image contrast reflecting the blood oxygen level. This blood oxygenation level-dependent (BOLD) contrast follows blood oxygen changes induced by anesthetics, by insulin-induced hypoglycemia, and by inhaled gas mixtures that alter metabolic demand or blood flow. The results suggest that BOLD contrast can be used to provide in vivo real-time maps of blood oxygenation in the brain under normal physiological conditions. BOLD contrast adds an additional feature to magnetic resonance imaging and complement other techniques that are attempting to provide position emission tomography-like measurements related to regional neural activity

  2. Field strength and dose dependence of contrast enhancement by gadolinium-based MR contrast agents

    International Nuclear Information System (INIS)

    Rinck, P.A.; Muller, R.N.

    1999-01-01

    The relaxivities r 1 and r 2 of magnetic resonance contrast agents and the T 1 relaxation time values of tissues are strongly field dependent. We present quantitative data and simulations of different gadolinium-based extracellular fluid contrast agents and the modulation of their contrast enhancement by the magnetic field to be able to answer the following questions: How are the dose and field dependences of their contrast enhancement? Is there an interrelationship between dose and field dependence? Should one increase or decrease doses at specific fields? Nuclear magnetic relaxation dispersion data were acquired for the following contrast agents: gadopentetate dimeglumine, gadoterate meglumine, gadodiamide injection, and gadoteridol injection, as well as for several normal and pathological human tissue samples. The magnetic field range stretched from 0.0002 to 4.7 T, including the entire clinical imaging range. The data acquired were then fitted with the appropriate theoretical models. The combination of the diamagnetic relaxation rates (R 1 = 1/T 1 and R 2 = 1/T 2 ) of tissues with the respective paramagnetic contributions of the contrast agents allowed the prediction of image contrast at any magnetic field. The results revealed a nearly identical field and dose-dependent increase of contrast enhancement induced by these contrast agents within a certain dose range. The target tissue concentration (TTC) was an important though nonlinear factor for enhancement. The currently recommended dose of 0.1 mmol/kg body weight seems to be a compromise close to the lower limits of diagnostically sufficient contrast enhancement for clinical imaging at all field strengths. At low field contrast enhancement might be insufficient. Adjustment of dose or concentration, or a new class of contrast agents with optimized relaxivity, would be a valuable contribution to a better diagnostic yield of contrast enhancement at all fields. (orig.)

  3. Cerebral misery perfusion diagnosed using hypercapnic blood-oxygenation-level-dependent contrast functional magnetic resonance imaging: a case report

    Directory of Open Access Journals (Sweden)

    D'Souza Olympio

    2010-02-01

    Full Text Available Abstract Introduction Cerebral misery perfusion represents a failure of cerebral autoregulation. It is an important differential diagnosis in post-stroke patients presenting with collapses in the presence of haemodynamically significant cerebrovascular stenosis. This is particularly the case when cortical or internal watershed infarcts are present. When this condition occurs, further investigation should be done immediately. Case presentation A 50-year-old Caucasian man presented with a stroke secondary to complete occlusion of his left internal carotid artery. He went on to suffer recurrent seizures. Neuroimaging demonstrated numerous new watershed-territory cerebral infarcts. No source of arterial thromboembolism was demonstrable. Hypercapnic blood-oxygenation-level-dependent-contrast functional magnetic resonance imaging was used to measure his cerebrovascular reserve capacity. The findings were suggestive of cerebral misery perfusion. Conclusions Blood-oxygenation-level-dependent-contrast functional magnetic resonance imaging allows the inference of cerebral misery perfusion. This procedure is cheaper and more readily available than positron emission tomography imaging, which is the current gold standard diagnostic test. The most evaluated treatment for cerebral misery perfusion is extracranial-intracranial bypass. Although previous trials of this have been unfavourable, the results of new studies involving extracranial-intracranial bypass in high-risk patients identified during cerebral perfusion imaging are awaited. Cerebral misery perfusion is an important and under-recognized condition in which emerging imaging and treatment modalities present the possibility of practical and evidence-based management in the near future. Physicians should thus be aware of this disorder and of recent developments in diagnostic tests that allow its detection.

  4. Contrast media effect on interleukin-2 levels in human plasma in vitro

    International Nuclear Information System (INIS)

    Napolov, Yu.K.; Borsukova, N.M.; Shimanovskij, N.L.

    1992-01-01

    As shown in the study of bilignost, iodamide and triombrast action on interleukin-2 (IL-2) level in human plasma in vitro, these contrast media (2.5x10 -2 -2.5x10 -4 M) elevate IL-2 content in blood plasma of sensitive to contrast media subjects in dose-dependent manner

  5. Sonophoresis Using Ultrasound Contrast Agents: Dependence on Concentration.

    Directory of Open Access Journals (Sweden)

    Donghee Park

    Full Text Available Sonophoresis can increase skin permeability to various drugs in transdermal drug delivery. Cavitation is recognized as the predominant mechanism of sonophoresis. Recently, a new logical approach to enhance the efficiency of transdermal drug delivery was tried. It is to utilize the engineered microbubble and its resonant frequency for increase of cavitation activity. Actively-induced cavitation with low-intensity ultrasound (less than ~1 MPa causes disordering of the lipid bilayers and the formation of aqueous channels by stable cavitation which indicates a continuous oscillation of bubbles. Furthermore, the mutual interactions of microbubble determined by concentration of added bubble are also thought to be an important factor for activity of stable cavitation, even in different characteristics of drug. In the present study, we addressed the dependence of ultrasound contrast agent concentration using two types of drug on the efficiency of transdermal drug delivery. Two types of experiment were designed to quantitatively evaluate the efficiency of transdermal drug delivery according to ultrasound contrast agent concentration. First, an experiment of optical clearing using a tissue optical clearing agent was designed to assess the efficiency of sonophoresis with ultrasound contrast agents. Second, a Franz diffusion cell with ferulic acid was used to quantitatively determine the amount of drug delivered to the skin sample by sonophoresis with ultrasound contrast agents. The maximum enhancement ratio of sonophoresis with a concentration of 1:1,000 was approximately 3.1 times greater than that in the ultrasound group without ultrasound contrast agent and approximately 7.5 times greater than that in the control group. These results support our hypothesis that sonophoresis becomes more effective in transdermal drug delivery due to the presence of engineered bubbles, and that the efficiency of transdermal drug delivery using sonophoresis with

  6. Sonophoresis Using Ultrasound Contrast Agents: Dependence on Concentration.

    Science.gov (United States)

    Park, Donghee; Song, Gillsoo; Jo, Yongjun; Won, Jongho; Son, Taeyoon; Cha, Ohrum; Kim, Jinho; Jung, Byungjo; Park, Hyunjin; Kim, Chul-Woo; Seo, Jongbum

    2016-01-01

    Sonophoresis can increase skin permeability to various drugs in transdermal drug delivery. Cavitation is recognized as the predominant mechanism of sonophoresis. Recently, a new logical approach to enhance the efficiency of transdermal drug delivery was tried. It is to utilize the engineered microbubble and its resonant frequency for increase of cavitation activity. Actively-induced cavitation with low-intensity ultrasound (less than ~1 MPa) causes disordering of the lipid bilayers and the formation of aqueous channels by stable cavitation which indicates a continuous oscillation of bubbles. Furthermore, the mutual interactions of microbubble determined by concentration of added bubble are also thought to be an important factor for activity of stable cavitation, even in different characteristics of drug. In the present study, we addressed the dependence of ultrasound contrast agent concentration using two types of drug on the efficiency of transdermal drug delivery. Two types of experiment were designed to quantitatively evaluate the efficiency of transdermal drug delivery according to ultrasound contrast agent concentration. First, an experiment of optical clearing using a tissue optical clearing agent was designed to assess the efficiency of sonophoresis with ultrasound contrast agents. Second, a Franz diffusion cell with ferulic acid was used to quantitatively determine the amount of drug delivered to the skin sample by sonophoresis with ultrasound contrast agents. The maximum enhancement ratio of sonophoresis with a concentration of 1:1,000 was approximately 3.1 times greater than that in the ultrasound group without ultrasound contrast agent and approximately 7.5 times greater than that in the control group. These results support our hypothesis that sonophoresis becomes more effective in transdermal drug delivery due to the presence of engineered bubbles, and that the efficiency of transdermal drug delivery using sonophoresis with microbubbles depends on the

  7. Thermal dependence of ultrasound contrast agents scattering efficiency for echographic imaging techniques

    Science.gov (United States)

    Biagioni, Angelo; Bettucci, Andrea; Passeri, Daniele; Alippi, Adriano

    2015-06-01

    Ultrasound contrast agents are used in echographic imaging techniques to enhance image contrast. In addition, they may represent an interesting solution to the problem of non-invasive temperature monitoring inside the human body, based on some thermal variations of their physical properties. Contrast agents, indeed, are inserted into blood circulation and they reach the most important organs inside the human body; consequently, any thermometric property that they may possess, could be exploited for realizing a non-invasive thermometer. They essentially are a suspension of microbubbles containing a gas enclosed in a phospholipid membrane; temperature variations induce structural modifications of the microbubble phospholipid shell, thus causing thermal dependence of contrast agent's elastic characteristics. In this paper, the acoustic scattering efficiency of a bulk suspension of of SonoVue® (Bracco SpA Milan, Italy) has been studied using a pulse-echo technique in the frequency range 1-17 MHz, as it depends upon temperatures between 25 and 65°C. Experimental data confirm that the ultrasonic attenuation coefficient of SonoVue® depends on temperature between 25 and 60°C. Chemical composition of the bubble shell seem to support the hypothesis that a phase transition in the microstructure of lipid-coated microbubbles could play a key role in explaining such effect.

  8. Parity dependence of the nuclear level density at high excitation

    International Nuclear Information System (INIS)

    Rao, B.V.; Agrawal, H.M.

    1995-01-01

    The basic underlying assumption ρ(l+1, J)=ρ(l, J) in the level density function ρ(U, J, π) has been checked on the basis of high quality data available on individual resonance parameters (E 0 , Γ n , J π ) for s- and p-wave neutrons in contrast to the earlier analysis where information about p-wave resonance parameters was meagre. The missing level estimator based on the partial integration over a Porter-Thomas distribution of neutron reduced widths and the Dyson-Mehta Δ 3 statistic for the level spacing have been used to ascertain that the s- and p-wave resonance level spacings D(0) and D(1) are not in error because of spurious and missing levels. The present work does not validate the tacit assumption ρ(l+1, J)=ρ(l, J) and confirms that the level density depends upon parity at high excitation. The possible implications of the parity dependence of the level density on the results of statistical model calculations of nuclear reaction cross sections as well as on pre-compound emission have been emphasized. (orig.)

  9. Wavelength-Dependent Differential Interference Contrast Microscopy: Selectively Imaging Nanoparticle Probes in Live Cells

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Wei; Wang, Gufeng; Fang, Ning; and Yeung, Edward S.

    2009-11-15

    Gold and silver nanoparticles display extraordinarily large apparent refractive indices near their plasmon resonance (PR) wavelengths. These nanoparticles show good contrast in a narrow spectral band but are poorly resolved at other wavelengths in differential interference contrast (DIC) microscopy. The wavelength dependence of DIC contrast of gold/silver nanoparticles is interpreted in terms of Mie's theory and DIC working principles. We further exploit this wavelength dependence by modifying a DIC microscope to enable simultaneous imaging at two wavelengths. We demonstrate that gold/silver nanoparticles immobilized on the same glass slides through hybridization can be differentiated and imaged separately. High-contrast, video-rate images of living cells can be recorded both with and without illuminating the gold nanoparticle probes, providing definitive probe identification. Dual-wavelength DIC microscopy thus presents a new approach to the simultaneous detection of multiple probes of interest for high-speed live-cell imaging.

  10. Technical Note: Measuring contrast- and noise-dependent spatial resolution of an iterative reconstruction method in CT using ensemble averaging

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Lifeng, E-mail: yu.lifeng@mayo.edu; Vrieze, Thomas J.; Leng, Shuai; Fletcher, Joel G.; McCollough, Cynthia H. [Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905 (United States)

    2015-05-15

    Purpose: The spatial resolution of iterative reconstruction (IR) in computed tomography (CT) is contrast- and noise-dependent because of the nonlinear regularization. Due to the severe noise contamination, it is challenging to perform precise spatial-resolution measurements at very low-contrast levels. The purpose of this study was to measure the spatial resolution of a commercially available IR method using ensemble-averaged images acquired from repeated scans. Methods: A low-contrast phantom containing three rods (7, 14, and 21 HU below background) was scanned on a 128-slice CT scanner at three dose levels (CTDI{sub vol} = 16, 8, and 4 mGy). Images were reconstructed using two filtered-backprojection (FBP) kernels (B40 and B20) and a commercial IR method (sinogram affirmed iterative reconstruction, SAFIRE, Siemens Healthcare) with two strength settings (I40-3 and I40-5). The same scan was repeated 100 times at each dose level. The modulation transfer function (MTF) was calculated based on the edge profile measured on the ensemble-averaged images. Results: The spatial resolution of the two FBP kernels, B40 and B20, remained relatively constant across contrast and dose levels. However, the spatial resolution of the two IR kernels degraded relative to FBP as contrast or dose level decreased. For a given dose level at 16 mGy, the MTF{sub 50%} value normalized to the B40 kernel decreased from 98.4% at 21 HU to 88.5% at 7 HU for I40-3 and from 97.6% to 82.1% for I40-5. At 21 HU, the relative MTF{sub 50%} value decreased from 98.4% at 16 mGy to 90.7% at 4 mGy for I40-3 and from 97.6% to 85.6% for I40-5. Conclusions: A simple technique using ensemble averaging from repeated CT scans can be used to measure the spatial resolution of IR techniques in CT at very low contrast levels. The evaluated IR method degraded the spatial resolution at low contrast and high noise levels.

  11. Electron dose dependence of signal-to-noise ratio, atom contrast and resolution in transmission electron microscope images

    International Nuclear Information System (INIS)

    Lee, Z.; Rose, H.; Lehtinen, O.; Biskupek, J.; Kaiser, U.

    2014-01-01

    In order to achieve the highest resolution in aberration-corrected (AC) high-resolution transmission electron microscopy (HRTEM) images, high electron doses are required which only a few samples can withstand. In this paper we perform dose-dependent AC-HRTEM image calculations, and study the dependence of the signal-to-noise ratio, atom contrast and resolution on electron dose and sampling. We introduce dose-dependent contrast, which can be used to evaluate the visibility of objects under different dose conditions. Based on our calculations, we determine optimum samplings for high and low electron dose imaging conditions. - Highlights: • The definition of dose-dependent atom contrast is introduced. • The dependence of the signal-to-noise ratio, atom contrast and specimen resolution on electron dose and sampling is explored. • The optimum sampling can be determined according to different dose conditions

  12. Energy dependence of contrast-detail-dose and object-detectability-dose curves for CT scanners

    International Nuclear Information System (INIS)

    Wagner, L.K.; Cohen, G.

    1982-01-01

    The energy dependence of contrast-detail-dose (CdD) and object-detectability-dose (OdD) curves for computed tomographic scanners is investigated. The effects of changes in beam energy on perceptibility are shown to be due to changes in signal-to-noise ratio resulting from changes in contrast and photon statistics. Energy-dependence analysis of OdD curves is shown to depend on the atomic composition of the phantom used to generate the curves, while such an analysis of CdD curves is independent of the atomic composition of the phantom. It is also shown that any OdD curve can be generated from CdD curves and that use of this fact rectifies any potential energy-dependent interpretation of CdD curves

  13. Polarization-dependent imaging contrast in abalone shells

    Science.gov (United States)

    Metzler, Rebecca A.; Zhou, Dong; Abrecht, Mike; Chiou, Jau-Wern; Guo, Jinghua; Ariosa, Daniel; Coppersmith, Susan N.; Gilbert, P. U. P. A.

    2008-02-01

    Many biominerals contain micro- or nanocrystalline mineral components, organized accurately into architectures that confer the material with improved mechanical performance at the macroscopic scale. We present here an effect which enables us to observe the relative orientation of individual crystals at the submicron scale. We call it polarization-dependent imaging contrast (PIC), as it is an imaging development of the well-known x-ray linear dichroism. Most importantly, PIC is obtained in situ, in biominerals. We present here PIC in the prismatic and nacreous layers of Haliotis rufescens (red abalone), confirm it in geologic calcite and aragonite, and corroborate the experimental data with theoretical simulated spectra. PIC reveals different and unexpected aspects of nacre architecture that have inspired theoretical models for nacre formation.

  14. Blood oxygenation level dependent (BOLD). Renal imaging. Concepts and applications; Blood Oxygenation Level Dependent (BOLD). Bildgebung der Nieren. Konzepte und Anwendungen

    Energy Technology Data Exchange (ETDEWEB)

    Nissen, Johanna C.; Haneder, Stefan; Schoenberg, Stefan O.; Michaely, Henrik J. [Heidelberg Univ. Medizinische Fakultaet Mannheim (Germany). Inst. fuer Klinische Radiologie und Nuklearmedizin; Mie, Moritz B.; Zoellner, Frank G. [Heidelberg Univ. Medizinische Fakultaet Mannheim (DE). Inst. fuer Computerunterstuetzte Klinische Medizin (CKM)

    2010-07-01

    Many renal diseases as well as several pharmacons cause a change in renal blood flow and/or renal oxygenation. The blood oxygenation level dependent (BOLD) imaging takes advantage of local field inhomogeneities and is based on a T2{sup *}-weighted sequence. BOLD is a non-invasive method allowing an estimation of the renal, particularly the medullary oxygenation, and an indirect measurement of blood flow without administration of contrast agents. Thus, effects of different drugs on the kidney and various renal diseases can be controlled and observed. This work will provide an overview of the studies carried out so far and identify ways how BOLD can be used in clinical studies. (orig.)

  15. Effects of computed tomography contrast medium factors on contrast enhancement

    International Nuclear Information System (INIS)

    Terasawa, Kazuaki; Hatcho, Atsushi; Okuda, Itsuko

    2011-01-01

    The various nonionic iodinated contrast media used in contrast computed tomography (CT) studies differ in terms of their composition, characteristics, and iodine concentration (mgI/ml), as well as the volume injected (ml). Compared with ionic iodinated contrast media, nonionic iodinated contrast media are low-osmolar agents, with different agents having different osmotic pressures. Using a custom-made phantom incorporating a semipermeable membrane, the osmotic flow rate (hounsfield unit (HU)/s) could easily be measured based on the observed increase in CT numbers, and the relationship between the osmotic pressure and the osmotic flow rate could be obtained (r 2 =0.84). In addition, taking the effects of patient size into consideration, the levels of contrast enhancement in the abdominal aorta (AA) and inferior vena cava (IVC) were compared among four types of CT contrast medium. The results showed differences in contrast enhancement in the IVC during the equilibrium phase depending on the type of contrast medium used. It was found that the factors responsible for the differences observed in enhancement in the IVC were the osmotic flow rate and the volume of the blood flow pathways in the circulatory system. It is therefore considered that the reproducibility of contrast enhancement is likely to be reduced in the examination of parenchymal organs, in which scanning must be performed during the equilibrium phase, even if the amount of iodine injected per unit body weight (mgI/kg) is maintained at a specified level. (author)

  16. Optimization of contrast-enhanced spectral mammography depending on clinical indication.

    Science.gov (United States)

    Dromain, Clarisse; Canale, Sandra; Saab-Puong, Sylvie; Carton, Ann-Katherine; Muller, Serge; Fallenberg, Eva Maria

    2014-10-01

    The objective is to optimize low-energy (LE) and high-energy (HE) exposure parameters of contrast-enhanced spectral mammography (CESM) examinations in four different clinical applications for which different levels of average glandular dose (AGD) and ratios between LE and total doses are required. The optimization was performed on a Senographe DS with a SenoBright® upgrade. Simulations were performed to find the optima by maximizing the contrast-to-noise ratio (CNR) on the recombined CESM image using different targeted doses and LE image quality. The linearity between iodine concentration and CNR as well as the minimal detectable iodine concentration was assessed. The image quality of the LE image was assessed on the CDMAM contrast-detail phantom. Experiments confirmed the optima found on simulation. The CNR was higher for each clinical indication than for SenoBright®, including the screening indication for which the total AGD was 22% lower. Minimal iodine concentrations detectable in the case of a 3-mm-diameter round tumor were 12.5% lower than those obtained for the same dose in the clinical routine. LE image quality satisfied EUREF acceptable limits for threshold contrast. This newly optimized set of acquisition parameters allows increased contrast detectability compared to parameters currently used without a significant loss in LE image quality.

  17. Threshold-dependent variability of coronary artery calcification measurements - implications for contrast-enhanced multi-detector row-computed tomography

    International Nuclear Information System (INIS)

    Moselewski, Fabian; Ferencik, Maros; Achenbach, Stephan; Abbara, Suhny; Cury, Ricardo C.; Booth, Sarah L.; Jang, Ik-Kyung; Brady, Thomas J.; Hoffmann, Udo

    2006-01-01

    Introduction: The present study investigated the threshold-dependent variability of coronary artery calcification (CAC) measurements and the potential to quantify CAC in contrast-enhanced multi-detector row-computed tomography (MDCT). Methods: We compared the mean CT attenuation of CAC to luminal contrast enhancement of the coronary arteries in 30 patients (n = 30) undergoing standard coronary contrast-enhanced spiral MDCT. The modified Agatston score [AS], calcified plaque volume [CV], and mineral mass [MM]) at four different thresholds (130, 200, 300, and 400 HU) were measured in 50 patients who underwent non-contrast-enhanced MDCT. Results: Mean CT attenuation of CAC was similar to the attenuation of the contrast-enhanced coronary lumen (CAC 297.1 ± 68.7 HU versus 295 ± 65 HU (p < 0.0001), respectively). Above a threshold of 300 HU CAC measurements significantly varied to standard measurements obtained at a threshold of 130 HU (p < 0.0001). The threshold-dependent variation of MM measurements was significantly smaller than for AS and CV (130 HU versus 400 HU: 63, 75, and 81, respectively; p < 0.001). These differences resulted in a change of age and gender based percentile category for AS in 78% of subjects. Discussion: We demonstrated that CAC measurements are threshold dependent with MM measurements having significantly less variation than AS or CV. Due to the similarity of mean CT attenuation of CAC and the contrast-enhanced coronary lumen accurate quantification of CAC may be difficult in standard coronary contrast-enhanced spiral MDCT

  18. Threshold-dependent variability of coronary artery calcification measurements - implications for contrast-enhanced multi-detector row-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Moselewski, Fabian [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Ferencik, Maros [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Achenbach, Stephan [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Internal Medicine II (Cardiology), University of Erlangen (Germany); Abbara, Suhny [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Cury, Ricardo C. [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Booth, Sarah L. [Jean Mayer USDA Human Nutrition Research Center on Aging, 711 Washington St., Boston, MA 02114 (United States); Jang, Ik-Kyung [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Brady, Thomas J. [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Hoffmann, Udo [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States)]. E-mail: uhoffman@partners.org

    2006-03-15

    Introduction: The present study investigated the threshold-dependent variability of coronary artery calcification (CAC) measurements and the potential to quantify CAC in contrast-enhanced multi-detector row-computed tomography (MDCT). Methods: We compared the mean CT attenuation of CAC to luminal contrast enhancement of the coronary arteries in 30 patients (n = 30) undergoing standard coronary contrast-enhanced spiral MDCT. The modified Agatston score [AS], calcified plaque volume [CV], and mineral mass [MM] at four different thresholds (130, 200, 300, and 400 HU) were measured in 50 patients who underwent non-contrast-enhanced MDCT. Results: Mean CT attenuation of CAC was similar to the attenuation of the contrast-enhanced coronary lumen (CAC 297.1 {+-} 68.7 HU versus 295 {+-} 65 HU (p < 0.0001), respectively). Above a threshold of 300 HU CAC measurements significantly varied to standard measurements obtained at a threshold of 130 HU (p < 0.0001). The threshold-dependent variation of MM measurements was significantly smaller than for AS and CV (130 HU versus 400 HU: 63, 75, and 81, respectively; p < 0.001). These differences resulted in a change of age and gender based percentile category for AS in 78% of subjects. Discussion: We demonstrated that CAC measurements are threshold dependent with MM measurements having significantly less variation than AS or CV. Due to the similarity of mean CT attenuation of CAC and the contrast-enhanced coronary lumen accurate quantification of CAC may be difficult in standard coronary contrast-enhanced spiral MDCT.

  19. Investigations of internal noise levels for different target sizes, contrasts, and noise structures

    Science.gov (United States)

    Han, Minah; Choi, Shinkook; Baek, Jongduk

    2014-03-01

    To describe internal noise levels for different target sizes, contrasts, and noise structures, Gaussian targets with four different sizes (i.e., standard deviation of 2,4,6 and 8) and three different noise structures(i.e., white, low-pass, and highpass) were generated. The generated noise images were scaled to have standard deviation of 0.15. For each noise type, target contrasts were adjusted to have the same detectability based on NPW, and the detectability of CHO was calculated accordingly. For human observer study, 3 trained observers performed 2AFC detection tasks, and correction rate, Pc, was calculated for each task. By adding proper internal noise level to numerical observer (i.e., NPW and CHO), detectability of human observer was matched with that of numerical observers. Even though target contrasts were adjusted to have the same detectability of NPW observer, detectability of human observer decreases as the target size increases. The internal noise level varies for different target sizes, contrasts, and noise structures, demonstrating different internal noise levels should be considered in numerical observer to predict the detection performance of human observer.

  20. Blood oxygenation level dependent (BOLD). Renal imaging. Concepts and applications

    International Nuclear Information System (INIS)

    Nissen, Johanna C.; Haneder, Stefan; Schoenberg, Stefan O.; Michaely, Henrik J.

    2010-01-01

    Many renal diseases as well as several pharmacons cause a change in renal blood flow and/or renal oxygenation. The blood oxygenation level dependent (BOLD) imaging takes advantage of local field inhomogeneities and is based on a T2 * -weighted sequence. BOLD is a non-invasive method allowing an estimation of the renal, particularly the medullary oxygenation, and an indirect measurement of blood flow without administration of contrast agents. Thus, effects of different drugs on the kidney and various renal diseases can be controlled and observed. This work will provide an overview of the studies carried out so far and identify ways how BOLD can be used in clinical studies. (orig.)

  1. Low-level pixelated representations suffice for aesthetically pleasing contrast adjustment in photographs

    Directory of Open Access Journals (Sweden)

    Ghose Tandra

    2017-01-01

    Full Text Available Today’s web-based automatic image enhancement algorithms decide to apply an enhancement operation by searching for “similar” images in an online database of images and then applying the same level of enhancement as the image in the database. Two key bottlenecks in these systems are the storage cost for images and the cost of the search. Based on the principles of computational aesthetics, we consider storing task-relevant aesthetic summaries, a set of features which are sufficient to predict the level at which an image enhancement operation should be performed, instead of the entire image. The empirical question, then, is to ensure that the reduced representation indeed maintains enough information so that the resulting operation is perceived to be aesthetically pleasing to humans. We focus on the contrast adjustment operation, an important image enhancement primitive. We empirically study the efficacy of storing a pixelated summary of the 16 most representative colors of an image and performing contrast adjustments on this representation. We tested two variants of the pixelated image: a “mid-level pixelized version” that retained spatial relationships and allowed for region segmentation and grouping as in the original image and a “low-level pixelized-random version” which only retained the colors by randomly shuffling the 50 x 50 pixels. In an empirical study on 25 human subjects, we demonstrate that the preferred contrast for the low-level pixelized-random image is comparable to the original image even though it retains very few bits and no semantic information, thereby making it ideal for image matching and retrieval for automated contrast editing. In addition, we use an eye tracking study to show that users focus only on a small central portion of the low-level image, thus improving the performance of image search over commonly used computer vision algorithms to determine interesting key points.

  2. Polarization-dependent Imaging Contrast (PIC) mapping reveals nanocrystal orientation patterns in carbonate biominerals

    Energy Technology Data Exchange (ETDEWEB)

    Gilbert, Pupa U.P.A., E-mail: pupa@physics.wisc.edu [University of Wisconsin-Madison, Departments of Physics and Chemistry, Madison, WI 53706 (United States)

    2012-10-15

    Highlights: Black-Right-Pointing-Pointer Nanocrystal orientation shown by Polarization-dependent Imaging Contrast (PIC) maps. Black-Right-Pointing-Pointer PIC-mapping of carbonate biominerals reveals their ultrastructure at the nanoscale. Black-Right-Pointing-Pointer The formation mechanisms of biominerals is discovered by PIC-mapping using PEEM. -- Abstract: Carbonate biominerals are one of the most interesting systems a physicist can study. They play a major role in the CO{sub 2} cycle, they master templation, self-assembly, nanofabrication, phase transitions, space filling, crystal nucleation and growth mechanisms. A new imaging modality was introduced in the last 5 years that enables direct observation of the orientation of carbonate single crystals, at the nano- and micro-scale. This is Polarization-dependent Imaging Contrast (PIC) mapping, which is based on X-ray linear dichroism, and uses PhotoElectron Emission spectroMicroscopy (PEEM). Here we present PIC-mapping results from biominerals, including the nacre and prismatic layers of mollusk shells, and sea urchin teeth. We describe various PIC-mapping approaches, and show that these lead to fundamental discoveries on the formation mechanisms of biominerals.

  3. Effect of Intravenous Administration of Contrast Media on Serum Creatinine Levels in Neonates.

    Science.gov (United States)

    Bedoya, Maria A; White, Ammie M; Edgar, J Christopher; Pradhan, Madhura; Raab, Elisabeth L; Meyer, James S

    2017-08-01

    Purpose To assess the effect of intravenous contrast media on renal function in neonates. Materials and Methods Institutional review board approval was obtained with waiver of consent. Electronic health records from January 2011 to April 2013 were reviewed retrospectively. Measures of renal function were obtained in inpatient neonates who underwent magnetic resonance (MR) imaging or computed tomography (CT) and for whom serum creatinine (Cr) levels were obtained within 72 hours before imaging and at least one time after imaging (>1 day after administration of contrast material). A total of 140 neonates who received contrast material (59 who underwent CT with iohexol or iodixanol and 81 who underwent MR imaging with gadopentetate dimeglumine) were identified. These neonates were frequency matched according to sex, gestational and postnatal age, and preimaging serum Cr levels with neonates who underwent unenhanced MR imaging or CT. Cr levels and glomerular filtration rates (GFRs) were grouped according to when they were obtained (before imaging, 1-2 days after imaging, 3-5 days after imaging, 6-9 days after imaging, 10-45 days after imaging, and more than 45 days after imaging). Serum Cr levels and GFRs for each time period were compared between groups by using hierarchic regressions or χ 2 or Fisher exact tests and with repeated-measures analysis of variance to compare groups on the rate of change in serum Cr levels and GFRs from before to after imaging. Results Cr levels decreased and GFRs increased in both groups from before to after imaging (CT group, P ≤ .01; MR imaging group, P ≤ .01). The neonates who underwent contrast material-enhanced imaging and the neonates who underwent unenhanced imaging showed similar serum Cr levels at all examined time periods. Groups also did not differ in the proportion of neonates with serum Cr levels higher than the reference range (>0.4 mg/dL) at any time point (iodine- [P > .12] or gadolinium-based [P > .13] contrast

  4. On the dependence of centre-to-limb contrast function of the photospheric faculae on their brightness

    International Nuclear Information System (INIS)

    Akimov, L.A.; Belkina, I.L.; Dyatel, N.P.

    1988-01-01

    The photometric aspect of the facular model with horizontal inhomogeneities is considered. The modeling of such inhomogeneities can be represented by a relative shift along the sun radius of neighbouring in heliocentric angle Θ photospheric regions by the value of the optical depth Δτ. It is found that the calculated faculae contrast curve in continuum (λ ≅ 5000 A) depends sensitively on the size ratio of rising and sinking elements and on their relative shift in the optical depth. This causes the change of the peak in the contrast curve and in its intensity. The size of elements influences th contrast curve but slightly. The calculated contrast curve for Δτ=0,8 and for the size ratio of rising and sinking elements equal to 1 is in a good agreement with the observed contrast curve for strong faculae. The observed contrast curve for faint faculae gives a good fit to the calculated contrast curve for Δτ=0,4 and for the size ratio of rising and sinking structures equal to 1/5

  5. Estimating Age-Dependent Extinction: Contrasting Evidence from Fossils and Phylogenies.

    Science.gov (United States)

    Hagen, Oskar; Andermann, Tobias; Quental, Tiago B; Antonelli, Alexandre; Silvestro, Daniele

    2018-05-01

    The estimation of diversification rates is one of the most vividly debated topics in modern systematics, with considerable controversy surrounding the power of phylogenetic and fossil-based approaches in estimating extinction. Van Valen's seminal work from 1973 proposed the "Law of constant extinction," which states that the probability of extinction of taxa is not dependent on their age. This assumption of age-independent extinction has prevailed for decades with its assessment based on survivorship curves, which, however, do not directly account for the incompleteness of the fossil record, and have rarely been applied at the species level. Here, we present a Bayesian framework to estimate extinction rates from the fossil record accounting for age-dependent extinction (ADE). Our approach, unlike previous implementations, explicitly models unobserved species and accounts for the effects of fossil preservation on the observed longevity of sampled lineages. We assess the performance and robustness of our method through extensive simulations and apply it to a fossil data set of terrestrial Carnivora spanning the past 40 myr. We find strong evidence of ADE, as we detect the extinction rate to be highest in young species and declining with increasing species age. For comparison, we apply a recently developed analogous ADE model to a dated phylogeny of extant Carnivora. Although the phylogeny-based analysis also infers ADE, it indicates that the extinction rate, instead, increases with increasing taxon age. The estimated mean species longevity also differs substantially, with the fossil-based analyses estimating 2.0 myr, in contrast to 9.8 myr derived from the phylogeny-based inference. Scrutinizing these discrepancies, we find that both fossil and phylogeny-based ADE models are prone to high error rates when speciation and extinction rates increase or decrease through time. However, analyses of simulated and empirical data show that fossil-based inferences are more

  6. Time-Contrastive Learning Based DNN Bottleneck Features for Text-Dependent Speaker Verification

    DEFF Research Database (Denmark)

    Sarkar, Achintya Kumar; Tan, Zheng-Hua

    2017-01-01

    In this paper, we present a time-contrastive learning (TCL) based bottleneck (BN) feature extraction method for speech signals with an application to text-dependent (TD) speaker verification (SV). It is well-known that speech signals exhibit quasi-stationary behavior in and only in a short interval......, and the TCL method aims to exploit this temporal structure. More specifically, it trains deep neural networks (DNNs) to discriminate temporal events obtained by uniformly segmenting speech signals, in contrast to existing DNN based BN feature extraction methods that train DNNs using labeled data...... to discriminate speakers or pass-phrases or phones or a combination of them. In the context of speaker verification, speech data of fixed pass-phrases are used for TCL-BN training, while the pass-phrases used for TCL-BN training are excluded from being used for SV, so that the learned features can be considered...

  7. No apparent influence of psychometrically-defined schizotypy on orientation-dependent contextual modulation of visual contrast detection

    Directory of Open Access Journals (Sweden)

    Damien J. Mannion

    2017-01-01

    Full Text Available We investigated the relationship between psychometrically-defined schizotypy and the ability to detect a visual target pattern. Target detection is typically impaired by a surrounding pattern (context with an orientation that is parallel to the target, relative to a surrounding pattern with an orientation that is orthogonal to the target (orientation-dependent contextual modulation. Based on reports that this effect is reduced in those with schizophrenia, we hypothesised that there would be a negative relationship between the relative score on psychometrically-defined schizotypy and the relative effect of orientation-dependent contextual modulation. We measured visual contrast detection thresholds and scores on the Oxford-Liverpool Inventory of Feelings and Experiences (O-LIFE from a non-clinical sample (N = 100. Contrary to our hypothesis, we find an absence of a monotonic relationship between the relative magnitude of orientation-dependent contextual modulation of visual contrast detection and the relative score on any of the subscales of the O-LIFE. The apparent difference of this result with previous reports on those with schizophrenia suggests that orientation-dependent contextual modulation may be an informative condition in which schizophrenia and psychometrically-defined schizotypy are dissociated. However, further research is also required to clarify the strength of orientation-dependent contextual modulation in those with schizophrenia.

  8. Elevated arousal levels enhance contrast perception.

    Science.gov (United States)

    Kim, Dongho; Lokey, Savannah; Ling, Sam

    2017-02-01

    Our state of arousal fluctuates from moment to moment-fluctuations that can have profound impacts on behavior. Arousal has been proposed to play a powerful, widespread role in the brain, influencing processes as far ranging as perception, memory, learning, and decision making. Although arousal clearly plays a critical role in modulating behavior, the mechanisms underlying this modulation remain poorly understood. To address this knowledge gap, we examined the modulatory role of arousal on one of the cornerstones of visual perception: contrast perception. Using a reward-driven paradigm to manipulate arousal state, we discovered that elevated arousal state substantially enhances visual sensitivity, incurring a multiplicative modulation of contrast response. Contrast defines vision, determining whether objects appear visible or invisible to us, and these results indicate that one of the consequences of decreased arousal state is an impaired ability to visually process our environment.

  9. Local gray level S-curve transformation - A generalized contrast enhancement technique for medical images.

    Science.gov (United States)

    Gandhamal, Akash; Talbar, Sanjay; Gajre, Suhas; Hani, Ahmad Fadzil M; Kumar, Dileep

    2017-04-01

    Most medical images suffer from inadequate contrast and brightness, which leads to blurred or weak edges (low contrast) between adjacent tissues resulting in poor segmentation and errors in classification of tissues. Thus, contrast enhancement to improve visual information is extremely important in the development of computational approaches for obtaining quantitative measurements from medical images. In this research, a contrast enhancement algorithm that applies gray-level S-curve transformation technique locally in medical images obtained from various modalities is investigated. The S-curve transformation is an extended gray level transformation technique that results into a curve similar to a sigmoid function through a pixel to pixel transformation. This curve essentially increases the difference between minimum and maximum gray values and the image gradient, locally thereby, strengthening edges between adjacent tissues. The performance of the proposed technique is determined by measuring several parameters namely, edge content (improvement in image gradient), enhancement measure (degree of contrast enhancement), absolute mean brightness error (luminance distortion caused by the enhancement), and feature similarity index measure (preservation of the original image features). Based on medical image datasets comprising 1937 images from various modalities such as ultrasound, mammograms, fluorescent images, fundus, X-ray radiographs and MR images, it is found that the local gray-level S-curve transformation outperforms existing techniques in terms of improved contrast and brightness, resulting in clear and strong edges between adjacent tissues. The proposed technique can be used as a preprocessing tool for effective segmentation and classification of tissue structures in medical images. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Contrast media and glomerular filtration: dose dependence of clearance for three agents

    International Nuclear Information System (INIS)

    Baeck, S.E.K.; Krutzen, E.; Nilsson-Ehle, P.

    1988-01-01

    Determination of plasma clearance of contrast agents has been advocated as a means to assess glomerular filtration rate. To evaluate the feasibility of different agents for this purpose, we have compared, in healthy volunteers, the dose dependence of plasma clearance for three contrast media (iohexol, a nonionic agent, and iothalamate and metrizoate, which are ionic substances), with special emphasis on the lower dose range (2-20 mL corresponding to 0.9-12.9 g, depending on dose and agent). Iohexol and iothalamate were cleared at constant rates, irrespective of given dose, whereas metrizoate clearance increased significantly at lower doses. In general, the clearances or iothalamate and metrizoate were, respectively, moderately and markedly higher than that of iohexol. The clearance of different doses of metrizoate (2 mL versus a radiographic dose of 40 mL or more) was also compared with the clearance of [ 51 Cr]EDTA in two groups of patients with reduced renal function. When compared with [ 51 Cr]EDTA in patients with renal dysfunction, metrizoate was cleared significantly faster after a 2-mL dose, whereas clearances were identical when the metrizoate dose was 40 mL or more. These findings indicate that tubular secretion plays an active role in the elimination of metrizoate. The pharmacokinetic properties of iohexol, in combination with its low toxicity, make it a suitable agent for determination of glomerular filtration rate in clinical practice

  11. Single-source dual-energy spectral multidetector CT of pancreatic adenocarcinoma: Optimization of energy level viewing significantly increases lesion contrast

    International Nuclear Information System (INIS)

    Patel, B.N.; Thomas, J.V.; Lockhart, M.E.; Berland, L.L.; Morgan, D.E.

    2013-01-01

    Aim: To evaluate lesion contrast in pancreatic adenocarcinoma patients using spectral multidetector computed tomography (MDCT) analysis. Materials and methods: The present institutional review board-approved, Health Insurance Portability and Accountability Act of 1996 (HIPAA)-compliant retrospective study evaluated 64 consecutive adults with pancreatic adenocarcinoma examined using a standardized, multiphasic protocol on a single-source, dual-energy MDCT system. Pancreatic phase images (35 s) were acquired in dual-energy mode; unenhanced and portal venous phases used standard MDCT. Lesion contrast was evaluated on an independent workstation using dual-energy analysis software, comparing tumour to non-tumoural pancreas attenuation (HU) differences and tumour diameter at three energy levels: 70 keV; individual subject-optimized viewing energy level (based on the maximum contrast-to-noise ratio, CNR); and 45 keV. The image noise was measured for the same three energies. Differences in lesion contrast, diameter, and noise between the different energy levels were analysed using analysis of variance (ANOVA). Quantitative differences in contrast gain between 70 keV and CNR-optimized viewing energies, and between CNR-optimized and 45 keV were compared using the paired t-test. Results: Thirty-four women and 30 men (mean age 68 years) had a mean tumour diameter of 3.6 cm. The median optimized energy level was 50 keV (range 40–77). The mean ± SD lesion contrast values (non-tumoural pancreas – tumour attenuation) were: 57 ± 29, 115 ± 70, and 146 ± 74 HU (p = 0.0005); the lengths of the tumours were: 3.6, 3.3, and 3.1 cm, respectively (p = 0.026); and the contrast to noise ratios were: 24 ± 7, 39 ± 12, and 59 ± 17 (p = 0.0005) for 70 keV, the optimized energy level, and 45 keV, respectively. For individuals, the mean ± SD contrast gain from 70 keV to the optimized energy level was 59 ± 45 HU; and the mean ± SD contrast gain from the optimized energy level to 45 ke

  12. Computed tomography imaging with the Adaptive Statistical Iterative Reconstruction (ASIR) algorithm: dependence of image quality on the blending level of reconstruction.

    Science.gov (United States)

    Barca, Patrizio; Giannelli, Marco; Fantacci, Maria Evelina; Caramella, Davide

    2018-06-01

    Computed tomography (CT) is a useful and widely employed imaging technique, which represents the largest source of population exposure to ionizing radiation in industrialized countries. Adaptive Statistical Iterative Reconstruction (ASIR) is an iterative reconstruction algorithm with the potential to allow reduction of radiation exposure while preserving diagnostic information. The aim of this phantom study was to assess the performance of ASIR, in terms of a number of image quality indices, when different reconstruction blending levels are employed. CT images of the Catphan-504 phantom were reconstructed using conventional filtered back-projection (FBP) and ASIR with reconstruction blending levels of 20, 40, 60, 80, and 100%. Noise, noise power spectrum (NPS), contrast-to-noise ratio (CNR) and modulation transfer function (MTF) were estimated for different scanning parameters and contrast objects. Noise decreased and CNR increased non-linearly up to 50 and 100%, respectively, with increasing blending level of reconstruction. Also, ASIR has proven to modify the NPS curve shape. The MTF of ASIR reconstructed images depended on tube load/contrast and decreased with increasing blending level of reconstruction. In particular, for low radiation exposure and low contrast acquisitions, ASIR showed lower performance than FBP, in terms of spatial resolution for all blending levels of reconstruction. CT image quality varies substantially with the blending level of reconstruction. ASIR has the potential to reduce noise whilst maintaining diagnostic information in low radiation exposure CT imaging. Given the opposite variation of CNR and spatial resolution with the blending level of reconstruction, it is recommended to use an optimal value of this parameter for each specific clinical application.

  13. Single-source dual-energy spectral multidetector CT of pancreatic adenocarcinoma: optimization of energy level viewing significantly increases lesion contrast.

    Science.gov (United States)

    Patel, B N; Thomas, J V; Lockhart, M E; Berland, L L; Morgan, D E

    2013-02-01

    To evaluate lesion contrast in pancreatic adenocarcinoma patients using spectral multidetector computed tomography (MDCT) analysis. The present institutional review board-approved, Health Insurance Portability and Accountability Act of 1996 (HIPAA)-compliant retrospective study evaluated 64 consecutive adults with pancreatic adenocarcinoma examined using a standardized, multiphasic protocol on a single-source, dual-energy MDCT system. Pancreatic phase images (35 s) were acquired in dual-energy mode; unenhanced and portal venous phases used standard MDCT. Lesion contrast was evaluated on an independent workstation using dual-energy analysis software, comparing tumour to non-tumoural pancreas attenuation (HU) differences and tumour diameter at three energy levels: 70 keV; individual subject-optimized viewing energy level (based on the maximum contrast-to-noise ratio, CNR); and 45 keV. The image noise was measured for the same three energies. Differences in lesion contrast, diameter, and noise between the different energy levels were analysed using analysis of variance (ANOVA). Quantitative differences in contrast gain between 70 keV and CNR-optimized viewing energies, and between CNR-optimized and 45 keV were compared using the paired t-test. Thirty-four women and 30 men (mean age 68 years) had a mean tumour diameter of 3.6 cm. The median optimized energy level was 50 keV (range 40-77). The mean ± SD lesion contrast values (non-tumoural pancreas - tumour attenuation) were: 57 ± 29, 115 ± 70, and 146 ± 74 HU (p = 0.0005); the lengths of the tumours were: 3.6, 3.3, and 3.1 cm, respectively (p = 0.026); and the contrast to noise ratios were: 24 ± 7, 39 ± 12, and 59 ± 17 (p = 0.0005) for 70 keV, the optimized energy level, and 45 keV, respectively. For individuals, the mean ± SD contrast gain from 70 keV to the optimized energy level was 59 ± 45 HU; and the mean ± SD contrast gain from the optimized energy level to 45 keV was 31 ± 25 HU (p = 0

  14. Radiographic contrast media

    International Nuclear Information System (INIS)

    Golman, K.; Holtz, E.; Almen, T.

    1987-01-01

    Contrast media are used in diagnostic radiology to enhance the X-ray attenuation between a body structure of interest and the surrounding tissue. A detail becomes perceptible on a roentgenogram only when its contrast exceeds a minimum value in relation to the background. Small areas of interest must have higher contrast than the background. The contrast effect depends on concentration of the contrast media with the body. A high contrast media concentration difference thus gives rise to more morphological details in the radiographs. Contrast media can be divided into negative contrast media such as air and gas which attenuate X-rays less than the body tissues, and positive contrast materials which attenuate X-rays more than the body tissues. The positive contrast media all contain either iodine (atomic number 53) or barium (atomic number 56) and can be divided into water-insoluble and water-soluble contrast media

  15. The association between use of metformin and change in serum CO_2 level after administration of contrast medium

    International Nuclear Information System (INIS)

    Kim, S.K.; Jung, J.; Jung, J.H.; Kim, K.Y.; Baek, J.-H.; Hahm, J.R.

    2016-01-01

    Aim: To evaluate the changes in serum creatinine and total CO_2 levels in patients receiving metformin during administration of contrast medium. Materials and methods: Patient records from January 2012 to December 2012 after the administration of contrast medium were reviewed retrospectively. A total of 924 patients were included for the final analysis. Of them, 105 received metformin during contrast medium administration, 112 were taking other oral hypoglycaemic agents, and 707 patients were not diabetic (controls). Results: No significant change in total CO_2 levels was detected (p=0.678). Metabolic acidosis was present in 33 (31.4%) metformin users, 31 (28.6%) other oral hypoglycaemic agent users, and 153 (21.6%) control patients. In the present logistic regression analysis, age, baseline levels of creatinine, and total CO_2 levels were associated with metabolic acidosis after contrast medium exposure. Conclusion: These data indicate the presence of a coexisting risk factor, other than metformin use, associated with metabolic acidosis after contrast medium exposure. No relationship was found between the use of metformin and metabolic acidosis during contrast medium exposure. - Highlights: • The use of metformin was not associated with metabolic acidosis after contrast exposure. • The coexisting risk factors for metabolic acidosis were present in patient with metabolic acidosis after contrast exposure. • There is a need to consider the maintenance of metformin during a CT scan in patients with a low risk for lactic acidosis.

  16. Intracellular calcium levels can regulate Importin-dependent nuclear import

    International Nuclear Information System (INIS)

    Kaur, Gurpreet; Ly-Huynh, Jennifer D.; Jans, David A.

    2014-01-01

    Highlights: • High intracellular calcium inhibits Impα/β1- or Impβ1-dependent nuclear protein import. • The effect of Ca 2+ on nuclear import does not relate to changes in the nuclear pore. • High intracellular calcium can result in mislocalisation of Impβ1, Ran and RCC1. - Abstract: We previously showed that increased intracellular calcium can modulate Importin (Imp)β1-dependent nuclear import of SRY-related chromatin remodeling proteins. Here we extend this work to show for the first time that high intracellular calcium inhibits Impα/β1- or Impβ1-dependent nuclear protein import generally. The basis of this relates to the mislocalisation of the transport factors Impβ1 and Ran, which show significantly higher nuclear localization in contrast to various other factors, and RCC1, which shows altered subnuclear localisation. The results here establish for the first time that intracellular calcium modulates conventional nuclear import through direct effects on the nuclear transport machinery

  17. Intracellular calcium levels can regulate Importin-dependent nuclear import

    Energy Technology Data Exchange (ETDEWEB)

    Kaur, Gurpreet; Ly-Huynh, Jennifer D.; Jans, David A., E-mail: David.Jans@monash.edu

    2014-07-18

    Highlights: • High intracellular calcium inhibits Impα/β1- or Impβ1-dependent nuclear protein import. • The effect of Ca{sup 2+} on nuclear import does not relate to changes in the nuclear pore. • High intracellular calcium can result in mislocalisation of Impβ1, Ran and RCC1. - Abstract: We previously showed that increased intracellular calcium can modulate Importin (Imp)β1-dependent nuclear import of SRY-related chromatin remodeling proteins. Here we extend this work to show for the first time that high intracellular calcium inhibits Impα/β1- or Impβ1-dependent nuclear protein import generally. The basis of this relates to the mislocalisation of the transport factors Impβ1 and Ran, which show significantly higher nuclear localization in contrast to various other factors, and RCC1, which shows altered subnuclear localisation. The results here establish for the first time that intracellular calcium modulates conventional nuclear import through direct effects on the nuclear transport machinery.

  18. Spinal cord injury-induced immune deficiency syndrome enhances infection susceptibility dependent on lesion level.

    Science.gov (United States)

    Brommer, Benedikt; Engel, Odilo; Kopp, Marcel A; Watzlawick, Ralf; Müller, Susanne; Prüss, Harald; Chen, Yuying; DeVivo, Michael J; Finkenstaedt, Felix W; Dirnagl, Ulrich; Liebscher, Thomas; Meisel, Andreas; Schwab, Jan M

    2016-03-01

    Pneumonia is the leading cause of death after acute spinal cord injury and is associated with poor neurological outcome. In contrast to the current understanding, attributing enhanced infection susceptibility solely to the patient's environment and motor dysfunction, we investigate whether a secondary functional neurogenic immune deficiency (spinal cord injury-induced immune deficiency syndrome, SCI-IDS) may account for the enhanced infection susceptibility. We applied a clinically relevant model of experimental induced pneumonia to investigate whether the systemic SCI-IDS is functional sufficient to cause pneumonia dependent on spinal cord injury lesion level and investigated whether findings are mirrored in a large prospective cohort study after human spinal cord injury. In a mouse model of inducible pneumonia, high thoracic lesions that interrupt sympathetic innervation to major immune organs, but not low thoracic lesions, significantly increased bacterial load in lungs. The ability to clear the bacterial load from the lung remained preserved in sham animals. Propagated immune susceptibility depended on injury of central pre-ganglionic but not peripheral postganglionic sympathetic innervation to the spleen. Thoracic spinal cord injury level was confirmed as an independent increased risk factor of pneumonia in patients after motor complete spinal cord injury (odds ratio = 1.35, P spinal cord injury directly causes increased risk for bacterial infection in mice as well as in patients. Besides obvious motor and sensory paralysis, spinal cord injury also induces a functional SCI-IDS ('immune paralysis'), sufficient to propagate clinically relevant infection in an injury level dependent manner. © The Author (2016). Published by Oxford University Press on behalf of the Guarantors of Brain. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Contrasting hypoxic effects on breast cancer stem cell hierarchy is dependent on ER-α status.

    Science.gov (United States)

    Harrison, Hannah; Rogerson, Lynsey; Gregson, Hannah J; Brennan, Keith R; Clarke, Robert B; Landberg, Göran

    2013-02-15

    Tumor hypoxia is often linked to decreased survival in patients with breast cancer and current therapeutic strategies aim to target the hypoxic response. One way in which this is done is by blocking hypoxia-induced angiogenesis. Antiangiogenic therapies show some therapeutic potential with increased disease-free survival, but these initial promising results are short lived and followed by tumor progression. We hypothesized that this may be due to altered cancer stem cell (CSC) activity resulting from increased tumor hypoxia. We studied the effects of hypoxia on CSC activity, using in vitro mammosphere and holoclone assays as well as in vivo limiting dilution experiments, in 13 patient-derived samples and four cell lines. There was a HIF-1α-dependent CSC increase in ER-α-positive cancers following hypoxic exposure, which was blocked by inhibition of estrogen and Notch signaling. A contrasting decrease in CSC was seen in ER-α-negative cancers. We next developed a xenograft model of cell lines and patient-derived samples to assess the hypoxic CSC response. Varying sizes of xenografts were collected and analyzed for HIF1-α expression and CSC. The same ER-α-dependent contrasting hypoxic-CSC response was seen validating the initial observation. These data suggest that ER-α-positive and negative breast cancer subtypes respond differently to hypoxia and, as a consequence, antiangiogenic therapies will not be suitable for both subgroups.

  20. Factors that affect the level of detectability of objects of low contrast in diagnostic radiology

    International Nuclear Information System (INIS)

    Zuniga Vargas, F.

    2001-01-01

    The diagnosed imageneologia is every day more used by the medical staff to obtain diagnoses of diverse illnesses. In this branch, the conventional equipments of tubes of X Rays, equipments with fluoroscopic, angiographos, on-line tomographos, ultrasound equipment of magnetic resonance are used. All of them finally produce an image which will be used for the radiologist to evaluate the structures and pathology with in order to give to emit a good and precise diagnosis. From the total of radiation that the man receives annually, the medical irradiations are the main contributors after natural radiations. The applications of the ionized radiations in the medical area have as an objective to provide diagnosis or treatment to the ill patient. To obtain an image of good quality is fundamental, so that the doctor carries out a good diagnosis. The images depend on many physical factors, such as the type of the used equipment, ability of the operator that takes the badge, maintenance of the equipment, badge quality, etc. The images in which the diagnosis is based on are a gathering of gray different tones that draw the anatomy of interest. Therefore, an injury should have different physical characteristics (grosor, density) to stand out from its environment. This notable capacity is known as radiological contrast. Studies which allow the quantification of the radiation levels' effect, the optic badge densities and the observers' physical particularities for the detection of low-contrast objects have not been done in Costa Rica The physician is the one responsible of implementing the quality programs that lead to the gathering of better images. From now on, the asserted diagnosis falls right into the radiologist's experience, who receives the theoretical training and practices of the different diagnosed modalities during his or her residence's years. Besides, the radiologist can collaborate with the improvement of the accuracy of the diagnosis, if he or she recommends the

  1. The levels of triglyceride and total cholesterol in methamphetamine dependence.

    Science.gov (United States)

    Zhang, Meijuan; Lv, Dezhao; Zhou, Wu; Ji, Lili; Zhou, Beibei; Chen, Han; Gu, Yingying; Zhao, Jiyun; He, Jincai

    2017-04-01

    The serum triglyceride (TG) and total cholesterol (TC) levels have been reported altered in the traditional drug-dependence (such as marijuana and heroin). However, studies assessing the relationships among serum TC, TG, and methamphetamine (MA)-dependence have not been described well. In this study, our aim is to explore the serum TG and TC levels in large sample of MA-dependent patients. A retrospective study was conducted in 938 MA-dependent patients who were recruited between February 2, 2008 and March 11, 2013, with social characteristics and drug-dependence history (duration of MA use, routes of drug administration, and daily dose were collected). Then, the serum levels of TC, TG, glucose (GLU), body mass index (BMI), and blood pressure were measured among the participants. Meanwhile, 985 age- and gender-matched healthy people in the physical examination center were selected as control group. Compared with the control group, significant decreases of TC, TG, GLU, and BMI were observed in MA-dependent patients (P < 0.05). Besides, we found that the daily dose of MA use was associated with TC (β = -0.079, P = 0.015) and the duration of MA use was independently related to BMI (β = -0.071, P = 0.031). This study demonstrated that the levels of TC, TG, GLU, and BMI factors altered in the MA-dependent patients. In addition, there is a negative association between MA dependence and TC and BMI.

  2. Investigation of Pockels Cells Crystal Contrast Ratio Distribution

    Directory of Open Access Journals (Sweden)

    Giedrius Sinkevičius

    2017-07-01

    Full Text Available The BBO Pockel’s cell has been investigated. The investigation results of optimal operating area on the surface of the crystal dependent of intrinsic contrast ratio (ICR and voltage contrast ratio (VCR for Pockel’s cell are presented. The block diagram of Pockel’s cells contrast measurement stand and measurement methodology are introduced and discussed. The graphs of intrinsic contrast ratio distribution on crystal surface, contrast ratio with voltage dependency and voltage contrast ratio distribution on crystal surface with half-wave voltage are presented.

  3. Combined diffusion-weighted, blood oxygen level-dependent, and dynamic contrast-enhanced MRI for characterization and differentiation of renal cell carcinoma.

    Science.gov (United States)

    Notohamiprodjo, Mike; Staehler, Michael; Steiner, Nicole; Schwab, Felix; Sourbron, Steven P; Michaely, Henrik J; Helck, Andreas D; Reiser, Maximilian F; Nikolaou, Konstantin

    2013-06-01

    To investigate a multiparametric magnetic resonance imaging (MRI) approach comprising diffusion-weighted imaging (DWI), blood oxygen-dependent (BOLD), and dynamic contrast-enhanced (DCE) MRI for characterization and differentiation of primary renal cell carcinoma (RCC). Fourteen patients with clear-cell carcinoma and four patients with papillary RCC were examined with DWI, BOLD MRI, and DCE MRI at 1.5T. The apparent diffusion coefficient (ADC) was calculated with a monoexponential decay. The spin-dephasing rate R2* was derived from parametric R2* maps. DCE-MRI was analyzed using a two-compartment exchange model allowing separation of perfusion (plasma flow [FP] and plasma volume [VP]), permeability (permeability surface area product [PS]), and extravascular extracellular volume (VE). Statistical analysis was performed with Wilcoxon signed-rank test, Pearson's correlation coefficient, and receiver operating characteristic curve analysis. Clear-cell RCC showed higher ADC and lower R2* compared to papillary subtypes, but differences were not significant. FP of clear-cell subtypes was significantly higher than in papillary RCC. Perfusion parameters showed moderate but significant inverse correlation with R2*. VE showed moderate inverse correlation with ADC. Fp and Vp showed best sensitivity for histological differentiation. Multiparametric MRI comprising DWI, BOLD, and DCE MRI is feasible for assessment of primary RCC. BOLD moderately correlates to DCE MRI-derived perfusion. ADC shows moderate correlation to the extracellular volume, but does not correlate to tumor oxygenation or perfusion. In this preliminary study DCE-MRI appeared superior to BOLD and DWI for histological differentiation. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  4. Renal Safety of Iodinated Contrast Media Depending on Their Osmolarity – Current Outlooks

    International Nuclear Information System (INIS)

    Mruk, Bartosz

    2016-01-01

    Iodinated contrast media (ICM) are commonly administered pharmaceutical agents. Most often they are used intravenously and intraarterially. Although iodinated contrast agents are relatively safe and widely used, adverse events occur and questions remain about their use, safety, and interactions. The most important adverse effects of contrast media include hypersensitivity reactions, thyroid dysfunction, and contrast-induced nephropathy. Radiologists must be aware of the risk factors for reactions to contrast media. Nonionic iodinated contrast agents can be divided into monomeric, low-osmolar, and dimeric, iso-osmolar classes. The osmotic characteristics of contrast media have been a significant focus in many investigations of contrast-induced nephropathy

  5. Study of nuclear level density parameter and its temperature dependence

    International Nuclear Information System (INIS)

    Nasrabadi, M. N.; Behkami, A. N.

    2000-01-01

    The nuclear level density ρ is the basic ingredient required for theoretical studies of nuclear reaction and structure. It describes the statistical nuclear properties and is expressed as a function of various constants of motion such as number of particles, excitation energy and angular momentum. In this work the energy and spin dependence of nuclear level density will be presented and discussed. In addition the level density parameter α will be extracted from this level density information, and its temperature and mass dependence will be obtained

  6. Visible Contrast Energy Metrics for Detection and Discrimination

    Science.gov (United States)

    Ahumada, Albert; Watson, Andrew

    2013-01-01

    Contrast energy was proposed by Watson, Robson, & Barlow as a useful metric for representing luminance contrast target stimuli because it represents the detectability of the stimulus in photon noise for an ideal observer. Like the eye, the ear is a complex transducer system, but relatively simple sound level meters are used to characterize sounds. These meters provide a range of frequency sensitivity functions and integration times depending on the intended use. We propose here the use of a range of contrast energy measures with different spatial frequency contrast sensitivity weightings, eccentricity sensitivity weightings, and temporal integration times. When detection threshold are plotting using such measures, the results show what the eye sees best when these variables are taken into account in a standard way. The suggested weighting functions revise the Standard Spatial Observer for luminance contrast detection and extend it into the near periphery. Under the assumption that the detection is limited only by internal noise, discrimination performance can be predicted by metrics based on the visible energy of the difference images

  7. SERUM ACETYLCHOLINESTERASE LEVEL IN THE PATIENTS OF OPIOID (BROWN SUGAR) DEPENDENCE

    OpenAIRE

    Shah, Nilesh; Dave, Kirti

    1992-01-01

    The authors compared the serum acetylcholinesterase level in the patients of brown sugar dependence and the normal volunteers. Significantly lower level of serum acetylcholinesterase was found in patients of brown sugar dependence.

  8. Dengue-Immune Humans Have Higher Levels of Complement-Independent Enhancing Antibody than Complement-Dependent Neutralizing Antibody.

    Science.gov (United States)

    Yamanaka, Atsushi; Konishi, Eiji

    2017-09-25

    Dengue is the most important arboviral disease worldwide. We previously reported that most inhabitants of dengue-endemic countries who are naturally immune to the disease have infection-enhancing antibodies whose in vitro activity does not decrease in the presence of complement (complement-independent enhancing antibodies, or CiEAb). Here, we compared levels of CiEAb and complement-dependent neutralizing antibodies (CdNAb) in dengue-immune humans. A typical antibody dose-response pattern obtained in our assay system to measure the balance between neutralizing and enhancing antibodies showed both neutralizing and enhancing activities depending on serum dilution factor. The addition of complement to the assay system increased the activity of neutralizing antibodies at lower dilutions, indicating the presence of CdNAb. In contrast, similar dose-response curves were obtained with and without complement at higher dilutions, indicating higher levels of CiEAb than CdNAb. For experimental support for the higher CiEAb levels, a cocktail of mouse monoclonal antibodies against dengue virus type 1 was prepared. The antibody dose-response curves obtained in this assay, with or without complement, were similar to those obtained with human serum samples when a high proportion of D1-V-3H12 (an antibody exhibiting only enhancing activity and thus a model for CiEAb) was used in the cocktail. This study revealed higher-level induction of CiEAb than CdNAb in humans naturally infected with dengue viruses.

  9. Potential dependent superiority of gold nanoparticles in comparison to iodinated contrast agents

    International Nuclear Information System (INIS)

    Jackson, Price A.; Rahman, Wan Nordiana W. Abd.; Wong, Christopher J.; Ackerly, Trevor; Geso, Moshi

    2010-01-01

    Purpose: To identify the benefits in image contrast enhancement using gold nanoparticles (AuNPs) compared to conventional iodinated contrast media. Materials and methods: Gold nanoparticles and iodinated contrast media were evaluated for contrast enhancement at various X-ray tube potentials in an imaging phantom. Iopromide and AuNP suspension were equalized according to molar concentration of radiopaque element (0.5077 Mol/L). Contrast-to-noise ratio is used to quantify contrast enhancement. Both projectional radiographic (40-80 kVp) and computed tomography (CT) (80-140kVp) imaging modalities were examined. Results and conclusions: Findings indicate 89% improvement in CNR at low energies near the mammographic range (40 kVp). However, as expected no significant difference in enhancement was observed at potentials commonly used for angiography (around 80 kVp) probably due to the k-edge influence for iodine. At the highest energies typically available in computed tomography, significant improvement in contrast enhancement using gold nanoparticles is obtained, 114% greater CNR than that produced by iodine at 140 kVp. Experimental findings for 70-120 kVp spectra correlate well with the theoretical calculations based on linear attenuation coefficients. Superior attenuation of gold nanoparticles at low and high kVp potentials support their further (pre)clinical evaluation.

  10. Hemispheric lateralization for early auditory processing of lexical tones: dependence on pitch level and pitch contour.

    Science.gov (United States)

    Wang, Xiao-Dong; Wang, Ming; Chen, Lin

    2013-09-01

    In Mandarin Chinese, a tonal language, pitch level and pitch contour are two dimensions of lexical tones according to their acoustic features (i.e., pitch patterns). A change in pitch level features a step change whereas that in pitch contour features a continuous variation in voice pitch. Currently, relatively little is known about the hemispheric lateralization for the processing of each dimension. To address this issue, we made whole-head electrical recordings of mismatch negativity in native Chinese speakers in response to the contrast of Chinese lexical tones in each dimension. We found that pre-attentive auditory processing of pitch level was obviously lateralized to the right hemisphere whereas there is a tendency for that of pitch contour to be lateralized to the left. We also found that the brain responded faster to pitch level than to pitch contour at a pre-attentive stage. These results indicate that the hemispheric lateralization for early auditory processing of lexical tones depends on the pitch level and pitch contour, and suggest an underlying inter-hemispheric interactive mechanism for the processing. © 2013 Elsevier Ltd. All rights reserved.

  11. Relationship between systemic hemodynamics and ambulatory blood pressure level are sex dependent.

    Science.gov (United States)

    Alfie, J; Waisman, G D; Galarza, C R; Magi, M I; Vasvari, F; Mayorga, L M; Cámera, M I

    1995-12-01

    Sex-related differences in systemic hemodynamics were analyzed by means of cardiac index and systemic vascular resistance according to the level of daytime ambulatory blood pressure. In addition, we assessed the relations between ambulatory blood pressure measurements and systemic hemodynamics in male and female patients. We prospectively included 52 women and 53 men referred to our unit for evaluation of arterial hypertension. Women and men were grouped according to the level of daytime mean arterial pressure: or = 110 mm Hg. Patients underwent noninvasive evaluation of resting hemodynamics (impedance cardiography) and 24-hour ambulatory blood pressure monitoring. Compared with women men with lower daytime blood pressure had a 12% higher systemic vascular resistance index (P = NS) and a 14% lower cardiac index (P < .02), whereas men with higher daytime blood pressure had a 25% higher vascular resistance (P < .003) and a 21% lower cardiac index (P < .0004). Furthermore, in men systemic vascular resistance correlated positively with both daytime and nighttime systolic and diastolic blood pressures, whereas cardiac index correlated negatively only with daytime diastolic blood pressure. In contrast, women did not exhibit any significant correlation between hemodynamic parameters and ambulatory blood pressure measurements. In conclusion, sex-related differences in systemic hemodynamics were more pronounced in the group with higher daytime hypertension. The relations between systemic hemodynamics and ambulatory blood pressure level depended on the sex of the patient. In men a progressive circulatory impairment underlies the increasing level of ambulatory blood pressure, but this was not observed in women.

  12. Contrasting magmatic structures between small plutons and batholiths emplaced at shallow crustal level (Sierras de Córdoba, Argentina)

    Science.gov (United States)

    Pinotti, Lucio P.; D'Eramo, Fernando J.; Weinberg, Roberto F.; Demartis, Manuel; Tubía, José María; Coniglio, Jorge E.; Radice, Stefania; Maffini, M. Natalia; Aragón, Eugenio

    2016-11-01

    Processes like injection, magma flow and differentiation and influence of the regional strain field are here described and contrasted to shed light on their role in the formation of small plutons and large batholiths their magmatic structures. The final geometric and compositional arrangement of magma bodies are a complex record of their construction and internal flow history. Magma injection, flow and differentiation, as well as regional stresses, all control the internal nature of magma bodies. Large magma bodies emplaced at shallow crustal levels result from the intrusion of multiple magma batches that interact in a variety of ways, depending on internal and external dynamics, and where the early magmatic, growth-related structures are commonly overprinted by subsequent history. In contrast, small plutons emplaced in the brittle-ductile transition more likely preserve growth-related structures, having a relatively simple cooling history and limited internal magma flow. Outcrop-scale magmatic structures in both cases record a rich set of complementary information that can help elucidate their evolution. Large and small granitic bodies of the Sierra Pampeanas preserve excellent exposures of magmatic structures that formed as magmas stepped through different rheological states during pluton growth and solidification. These structures reveal not only the flow pattern inside magma chambers, but also the rheological evolution of magmas in response to temperature evolution.

  13. Properties of conventional contrast media

    International Nuclear Information System (INIS)

    Muetzel, W.

    1981-01-01

    A comprehensive overview is given of the properties of contrast media currently used in computed tomography (CT). The chemical structure of the compounds and the physicochemical properties derived therefrom are described. Emphasis is placed on the importance of the physicochemical properties of contrast media for tolerance and the pharmacokinetic behavior of compounds in the body. An outline is given of the basic ideas governing rational use of contrast media in CT, which result from complex, time-dependent distribution of contrast media in different tissue spaces. (Auth.)

  14. Dynamic full field OCT: metabolic contrast at subcellular level (Conference Presentation)

    Science.gov (United States)

    Apelian, Clement; Harms, Fabrice; Thouvenin, Olivier; Boccara, Claude A.

    2016-03-01

    Cells shape or density is an important marker of tissues pathology. However, individual cells are difficult to observe in thick tissues frequently presenting highly scattering structures such as collagen fibers. Endogenous techniques struggle to image cells in these conditions. Moreover, exogenous contrast agents like dyes, fluorophores or nanoparticles cannot always be used, especially if non-invasive imaging is required. Scatterers motion happening down to the millisecond scale, much faster than the still and highly scattering structures (global motion of the tissue), allowed us to develop a new approach based on the time dependence of the FF-OCT signals. This method reveals hidden cells after a spatiotemporal analysis based on singular value decomposition and wavelet analysis concepts. It does also give us access to local dynamics of imaged scatterers. This dynamic information is linked with the local metabolic activity that drives these scatterers. Our technique can explore subcellular scales with micrometric resolution and dynamics ranging from the millisecond to seconds. By this mean we studied a wide range of tissues, animal and human in both normal and pathological conditions (cancer, ischemia, osmotic shock…) in different organs such as liver, kidney, and brain among others. Different cells, undetectable with FF-OCT, were identified (erythrocytes, hepatocytes…). Different scatterers clusters express different characteristic times and thus can be related to different mechanisms that we identify with metabolic functions. We are confident that the D-FFOCT, by accessing to a new spatiotemporal metabolic contrast, will be a leading technique on tissue imaging and for better medical diagnosis.

  15. Maternal high-fat diet and offspring expression levels of vitamin K-dependent proteins.

    Science.gov (United States)

    Lanham, S A; Cagampang, F R; Oreffo, R O C

    2014-12-01

    Studies suggest that bone growth and development and susceptibility to vascular disease in later life are influenced by maternal nutrition during intrauterine and early postnatal life. There is evidence for a role of vitamin K-dependent proteins (VKDPs) including osteocalcin, matrix Gla protein, periostin, and growth-arrest specific- protein 6, in both bone and vascular development. We have examined whether there are alterations in these VKDPs in bone and vascular tissue from offspring of mothers subjected to a nutritional challenge: a high-fat diet during pregnancy and postnatally, using 6-week-old mouse offspring. Bone site-specific and sex-specific differences across femoral and vertebral bone in male and female offspring were observed. Overall a high-fat maternal diet and offspring diet exacerbated the bone changes observed. Sex-specific differences and tissue-specific differences were observed in VKDP levels in aorta tissue from high-fat diet-fed female offspring from high-fat diet-fed mothers displaying increased levels of Gas6 and Ggcx compared with those of female controls. In contrast, differences were seen in VKDP levels in femoral bone of female offspring with lower expression levels of Mgp in offspring of mothers fed a high-fat diet compared with those of controls. We observed a significant correlation in Mgp expression levels within the femur to measures of bone structure of the femur and vertebra, particularly in the male offspring cohort. In summary, the current study has highlighted the importance of maternal nutrition on offspring bone development and the correlation of VKDPs to bone structure.

  16. Effect of temperature-dependent energy-level shifts on a semiconductor's Peltier heat

    International Nuclear Information System (INIS)

    Emin, D.

    1984-01-01

    The Peltier heat of a charge carrier in a semiconductor is calculated for the situation in which the electronic energy levels are temperature dependent. The temperature dependences of the electronic energy levels, generally observed optically, arise from their dependences on the vibrational energy of the lattice (e.g., as caused by thermal expansion). It has been suggested that these temperature dependences will typically have a major effect on the Peltier heat. The Peltier heat associated with a given energy level is a thermodynamic quantity; it is the product of the temperature and the change of the entropy of the system when a carrier is added in that level. As such, the energy levels cannot be treated as explicitly temperature dependent. The electron-lattice interaction causing the temperature dependence must be expressly considered. It is found that the carrier's interaction with the atomic vibrations lowers its electronic energy. However, the interaction of the carrier with the atomic vibrations also causes an infinitesimal lowering (approx.1/N) of each of the N vibrational frequencies. As a result, there is a finite carrier-induced increase in the average vibrational energy. Above the Debye temperature, this cancels the lowering of the carrier's electronic energy. Thus, the standard Peltier-heat formula, whose derivation generally ignores the temperature dependence of the electronic energy levels, is regained. This explains the apparent success of the standard formula in numerous analyses of electronic transport experiments

  17. Capturing age-related changes in functional contrast sensitivity with decreasing light levels in monocular and binocular vision.

    Science.gov (United States)

    Gillespie-Gallery, Hanna; Konstantakopoulou, Evgenia; Harlow, Jonathan A; Barbur, John L

    2013-09-09

    It is challenging to separate the effects of normal aging of the retina and visual pathways independently from optical factors, decreased retinal illuminance, and early stage disease. This study determined limits to describe the effect of light level on normal, age-related changes in monocular and binocular functional contrast sensitivity. We recruited 95 participants aged 20 to 85 years. Contrast thresholds for correct orientation discrimination of the gap in a Landolt C optotype were measured using a 4-alternative, forced-choice (4AFC) procedure at screen luminances from 34 to 0.12 cd/m(2) at the fovea and parafovea (0° and ±4°). Pupil size was measured continuously. The Health of the Retina index (HRindex) was computed to capture the loss of contrast sensitivity with decreasing light level. Participants were excluded if they exhibited performance outside the normal limits of interocular differences or HRindex values, or signs of ocular disease. Parafoveal contrast thresholds showed a steeper decline and higher correlation with age at the parafovea than the fovea. Of participants with clinical signs of ocular disease, 83% had HRindex values outside the normal limits. Binocular summation of contrast signals declined with age, independent of interocular differences. The HRindex worsens more rapidly with age at the parafovea, consistent with histologic findings of rod loss and its link to age-related degenerative disease of the retina. The HRindex and interocular differences could be used to screen for and separate the earliest stages of subclinical disease from changes caused by normal aging.

  18. Excitation energy and angular momentum dependence of the nuclear level densities

    International Nuclear Information System (INIS)

    Razavi, R.; Kakavand, T.; Behkami, A. N.

    2007-01-01

    We have investigated the excitation energy (E) dependence of nuclear level density for Bethe formula and constant temperature model. The level density parameter aa nd the back shifted energy from the Bethe formula are obtained by fitting the complete level schemes. Also the level density parameters from the constant temperature model have been determined for several nuclei. we have shown that the microscopic theory provides more precise information on the nuclear level densities. On the other hand, the spin cut-off parameter and effective moment of inertia are determined by studying of the angular momentum (J) dependence of the nuclear level density, and effective moment of inertia is compared with rigid body value.

  19. Recalled first reactions to inhaling nicotine predict the level of physical dependence.

    Science.gov (United States)

    Wellman, Robert J; DiFranza, Joseph R; O'Loughlin, Jennifer

    2014-10-01

    The level of physical dependence is a measure of addiction that correlates highly with addiction-associated changes in brain structure. We sought to determine whether age at first inhalation and initial reactions to inhaling nicotine are related to level of physical dependence in early adulthood. Young adults (n=312; mean age=24 years; 51% female) from the Nicotine Dependence in Teens study who had smoked at least once in the preceding three months completed self-report questionnaires in 2011-12. We assessed level of physical dependence with three validated self-report items assessing 'wanting,' 'craving' and 'needing' triggered by nicotine deprivation. Survey items assessed smoking behavior, including age at first inhalation, and recalled first reactions to inhaling nicotine. After adjusting for covariates, experiencing relaxation, heart racing/pounding, rush or "buzz" (OR=1.45; 95% CI: 1.08, 1.94) and dizziness (OR=1.58; 95% CI: 1.15, 2.18) at first nicotine inhalation were associated with an increased odds of being at a higher level of physical dependence in young adulthood; the association for experiencing relaxation (OR=1.78; 95% CI: 1.20, 2.64) and heart racing/pounding (OR=1.51; 95% CI: 1.00, 2.28) persisted after additionally controlling for all other first reactions. Neither age at first inhalation nor unpleasant first reactions predicted level of physical dependence. In accordance with prior research, our findings suggest that smokers who are particularly sensitive to the pleasant, "buzz-related" and generally arousing effects of nicotine may be more likely to attain higher levels of physical dependence. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  20. Contrasting gender differences on two measures of exercise dependence.

    Science.gov (United States)

    Weik, M; Hale, B D

    2009-03-01

    Recent studies using multidimensional measures have shown that men (Exercise Dependence Scale; EDS-R) are more exercise-dependent than women, whereas others have found that women (Exercise Dependence Questionnaire; EDQ) are more exercise-dependent than men. This study investigated whether there may be sex differences in exercise dependence or whether the questionnaires may be measuring different dimensions of exercise dependence. Regular exercisers voluntarily completed the EDS-R, EDQ and Drive for Thinness (DFT) subscale before or after a workout. A local health club in the eastern USA. Male (n = 102) and female (n = 102) exercisers completed the three questionnaires, but 11 participants (1 man, 10 women) were excluded from further analysis because scores indicated possible secondary exercise dependence (eating disorder). Eight subscales of the EDQ, seven subscales of the EDS, the DFT subscale, and several demographic variables served as dependent measures. A multivariate analysis of variance (MANOVA) on the EDS-R showed that men were significantly higher than women on the Withdrawal, Continuance, Tolerance, Lack of Control, Time, and Intention Effect subscales. Another MANOVA on the EDQ indicated that women scored significantly higher than did men on the Interference, Positive Rewards, Withdrawal, and Social Reasons subscales. Statistical analysis using t tests revealed that men had significantly higher total EDS-R scores than women, but women had significantly higher EDQ and DFT scores. These results suggest that both questionnaires measure different aspects of exercise dependence that favour either gender. It remains for further research to determine whether these instruments are equally viable for measurement of ED in both men and women.

  1. Contrast configuration influences grouping in apparent motion.

    Science.gov (United States)

    Ma-Wyatt, Anna; Clifford, Colin W G; Wenderoth, Peter

    2005-01-01

    We investigated whether the same principles that influence grouping in static displays also influence grouping in apparent motion. Using the Ternus display, we found that the proportion of group motion reports was influenced by changes in contrast configuration. Subjects made judgments of completion of these same configurations in a static display. Generally, contrast configurations that induced a high proportion of group motion responses were judged as more 'complete' in static displays. Using a stereo display, we then tested whether stereo information and T-junction information were critical for this increase in group motion. Perceived grouping was consistently higher for same contrast polarity configurations than for opposite contrast polarity configurations, regardless of the presence of stereo information or explicit T-junctions. Thus, while grouping in static and moving displays showed a similar dependence on contrast configuration, motion grouping showed little dependence on stereo or T-junction information.

  2. Exchange-Mediated Contrast in CEST and Spin-Lock Imaging

    Science.gov (United States)

    Cobb, Jared Guthrie; Li, Ke; Xie, Jingping; Gochberg, Daniel F.; Gore, John C.

    2014-01-01

    PURPOSE Magnetic resonance images of biological media based on chemical exchange saturation transfer (CEST) show contrast that depends on chemical exchange between water and other protons. In addition, spin-lattice relaxation rates in the rotating frame (R1ρ) are also affected by exchange, especially at high fields, and can be exploited to provide novel, exchange-dependent contrast. Here, we evaluate and compare the factors that modulate the exchange contrast for these methods using simulations and experiments on simple, biologically relevant samples. METHODS Simulations and experimental measurements at 9.4T of rotating frame relaxation rate dispersion and CEST contrast were performed on solutions of macromolecules containing amide and hydroxyl exchanging protons. RESULTS The simulations and experimental measurements confirm that both CEST and R1ρ measurements depend on similar exchange parameters, but they manifest themselves differently in their effects on contrast. CEST contrast may be larger in the slow and intermediate exchange regimes for protons with large resonant frequency offsets (e.g. > 2ppm). Spin-locking techniques can produce larger contrast enhancement when resonant frequency offsets are small (exchange is in the intermediate to fast regime. The image contrasts scale differently with field strength, exchange rate and concentration. CONCLUSION CEST and R1ρ measurements provide different and somewhat complementary information about exchange in tissues. Whereas CEST can depict exchange of protons with specific chemical shifts, appropriate R1ρ dependent acquisitions can be employed to selectively portray protons of specific exchange rates. PMID:24239335

  3. Exchange-mediated contrast in CEST and spin-lock imaging.

    Science.gov (United States)

    Cobb, Jared Guthrie; Li, Ke; Xie, Jingping; Gochberg, Daniel F; Gore, John C

    2014-01-01

    Magnetic resonance images of biological media based on chemical exchange saturation transfer (CEST) show contrast that depends on chemical exchange between water and other protons. In addition, spin-lattice relaxation rates in the rotating frame (R1ρ) are also affected by exchange, especially at high fields, and can be exploited to provide novel, exchange-dependent contrast. Here, we evaluate and compare the factors that modulate the exchange contrast for these methods using simulations and experiments on simple, biologically relevant samples. Simulations and experimental measurements at 9.4 T of rotating frame relaxation rate dispersion and CEST contrast were performed on solutions of macromolecules containing amide and hydroxyl exchanging protons. The simulations and experimental measurements confirm that both CEST and R1ρ measurements depend on similar exchange parameters, but they manifest themselves differently in their effects on contrast. CEST contrast may be larger in the slow and intermediate exchange regimes for protons with large resonant frequency offsets (e.g. >2 ppm). Spin-locking techniques can produce larger contrast enhancement when resonant frequency offsets are small (exchange is in the intermediate-to-fast regime. The image contrasts scale differently with field strength, exchange rate and concentration. CEST and R1ρ measurements provide different and somewhat complementary information about exchange in tissues. Whereas CEST can depict exchange of protons with specific chemical shifts, appropriate R1ρ-dependent acquisitions can be employed to selectively portray protons of specific exchange rates. © 2013.

  4. Spectral triangulation molecular contrast optical coherence tomography with indocyanine green as the contrast agent

    OpenAIRE

    Yang, Changhuei; McGuckin, Laura E. L.; Simon, John D.; Choma, Michael A.; Applegate, Brian E.; Izatt, Joseph A.

    2004-01-01

    We report a new molecular contrast optical coherence tomography (MCOCT) implementation that profiles the contrast agent distribution in a sample by measuring the agent's spectral differential absorption. The method, spectra triangulation MCOCT, can effectively suppress contributions from spectrally dependent scatterings from the sample without a priori knowledge of the scattering properties. We demonstrate molecular imaging with this new MCOCT modality by mapping the distribution of indocyani...

  5. Working together versus working autonomously: a new power-dependence perspective on the individual-level of analysis.

    Science.gov (United States)

    de Jong, Simon B

    2014-01-01

    Recent studies have indicated that it is important to investigate the interaction between task interdependence and task autonomy because this interaction can affect team effectiveness. However, only a limited number of studies have been conducted and those studies focused solely on the team level of analysis. Moreover, there has also been a dearth of theoretical development. Therefore, this study develops and tests an alternative theoretical perspective in an attempt to understand if, and if so why, this interaction is important at the individual level of analysis. Based on interdependence theory and power-dependence theory, we expected that highly task-interdependent individuals who reported high task autonomy would be more powerful and better performers. In contrast, we expected that similarly high task-interdependent individuals who reported less task autonomy would be less powerful and would be weaker performers. These expectations were supported by multi-level and bootstrapping analyses performed on a multi-source dataset (self-, peer-, manager-ratings) comprised of 182 employees drawn from 37 teams. More specifically, the interaction between task interdependence and task autonomy was γ =.128, p power and γ =.166, p <.05 for individual performance. The 95% bootstrap interval ranged from .0038 to .0686.

  6. Evaluating nicotine dependence levels in e-cigarette users.

    Science.gov (United States)

    González Roz, Alba; Secades Villa, Roberto; Weidberg, Sara

    2017-01-11

    Despite the fact that electronic cigarettes (e-cigarettes) are rapidly growing in popularity and use worldwide, there is scarce scientific data on abuse liability among e-cigarette users, and about whether e-cigarette use is related to nicotine dependence or not. The aim of this study is to explore nicotine dependence levels in a sample of experienced e-cigarette users (n= 39) and to compare them with current tobacco cigarette smokers (n=42). We conducted several face-to-face interviews in order to assess sociodemographic and dependence related characteristics in both e-cigarette users and in smokers. Adapted versions of both the Fagerström test for nicotine dependence (FTND) and the nicotine dependence syndrome scale (NDSS) were used to analyze nicotine dependence in each of the groups. Biochemical markers of carbon monoxide and urinary cotinine analysis were also collected. Results showed that e-cigarette users scored lower than cigarette smokers in both FTND and all NDSS subscales. Our findings extend previous research on e-cigarette use and nicotine addiction and suggest that e-cigarette users are less dependent on nicotine than current tobacco cigarette smokers. Further prospective studies are needed to better ascertain their addictiveness potential, comparing those smokers who switched to e-cigarettes from smoking cigarettes, and those who had never been tobacco cigarette smokers.

  7. Generalized image contrast enhancement technique based on the Heinemann contrast discrimination model

    Science.gov (United States)

    Liu, Hong; Nodine, Calvin F.

    1996-07-01

    This paper presents a generalized image contrast enhancement technique, which equalizes the perceived brightness distribution based on the Heinemann contrast discrimination model. It is based on the mathematically proven existence of a unique solution to a nonlinear equation, and is formulated with easily tunable parameters. The model uses a two-step log-log representation of luminance contrast between targets and surround in a luminous background setting. The algorithm consists of two nonlinear gray scale mapping functions that have seven parameters, two of which are adjustable Heinemann constants. Another parameter is the background gray level. The remaining four parameters are nonlinear functions of the gray-level distribution of the given image, and can be uniquely determined once the previous three are set. Tests have been carried out to demonstrate the effectiveness of the algorithm for increasing the overall contrast of radiology images. The traditional histogram equalization can be reinterpreted as an image enhancement technique based on the knowledge of human contrast perception. In fact, it is a special case of the proposed algorithm.

  8. Patients' oral hydration levels and incidence of immediate to short-term mild side-effects in contrast agent enhanced MRI diagnostics

    International Nuclear Information System (INIS)

    Jonker, Leon; Fallahi, Farshid

    2015-01-01

    Aim: Gadolinium-based contrast agents for radiodiagnostic purposes can lead to side effects, including nephrotoxicity in patients with renal insufficiency. This study evaluated whether the occurrence of mild side effects from gadolinium-based contrast enhanced magnetic resonance imaging (MRI) correlates to patients' oral hydration levels. Methods: Oral fluid intake levels 24 h pre- and 24 h post-MRI, as well as incidence of mild side-effects experienced 30 min and 24 h post-MRI were recorded by using a patient self-reporting questionnaire. Results: A total of 174 patients, 29 controls, 98 administered Prohance and 47 receiving Dotarem, were enrolled. Overall, the most frequently reported side-effect was headache; nausea only occurred in patients receiving contrast agent. One or more side-effects experienced 24 h following the MRI scan were reported by 10% (controls), 24% (Prohance) and 22% (Dotarem) of patients, respectively. Multivariate ordinal regression analysis showed that only male gender (OR 0.24, 95% CI 0.11–0.53) was statistically significantly associated with a decreased incidence of side-effects 30 min after MRI. At 24-h post MRI, a lack of contrast agent (OR 0.40, 95% CI 0.09–1.74) and male gender (OR 0.46, 95% CI 0.19–1.09) were associated with fewer side-effects. Conclusions: The level oral fluid intake before and after undergoing gadolinium-based contrast-enhanced MRI does not appear to markedly affect the incidence of common undesirable mild symptoms experienced shortly after the procedure. Confounding differences between patients in reporting side-effects may contribute to these findings. - Highlights: • We assess the incidence of patient-reported side-effects after contrast-enhanced MRI. • We examine the potential impact of oral hydration levels on side-effects. • Patient reported side-effects are high compared to those reported by clinicians. • Female gender and contrast agent itself are associated with increased side

  9. Dependence of the subharmonic signal from contrast agent microbubbles on ambient pressure: A theoretical analysis.

    Science.gov (United States)

    Jiménez-Fernández, J

    2018-01-01

    This paper investigates the dependence of the subharmonic response in a signal scattered by contrast agent microbubbles on ambient pressure to provide quantitative estimations of local blood pressure. The problem is formulated by assuming a gas bubble encapsulated by a shell of finite thickness with dynamic behavior modeled by a nonlinear viscoelastic constitutive equation. For ambient overpressure compatible with the clinical range, the acoustic pressure intervals where the subharmonic signal may be detected (above the threshold for the onset and below the limit value for the first chaotic transition) are determined. The analysis shows that as the overpressure is increased, all harmonic components are displaced to higher frequencies. This displacement is significant for the subharmonic of order 1/2 and explains the increase or decrease in the subharmonic amplitude with ambient pressure described in previous works. Thus, some questions related to the monotonic dependence of the subharmonic amplitude on ambient pressure are clarified. For different acoustic pressures, quantitative conditions for determining the intervals where the subharmonic amplitude is a monotonic or non-monotonic function of the ambient pressure are provided. Finally, the influence of the ambient pressure on the subharmonic resonance frequency is analyzed.

  10. Dialysis and contrast media

    International Nuclear Information System (INIS)

    Morcos, Sameh K.; Thomsen, Henrik S.; Webb, Judith A.W.

    2002-01-01

    In a previous survey we revealed uncertainty among responders about (a) whether or not to perform hemodialysis in patients with severely reduced renal function who had received contrast medium; and (b) when to perform hemodialysis in patients on regular treatment with hemodialysis or continuous ambulatory dialysis who received contrast medium. Therefore, the Contrast Media Safety Committee of The European Society of Urogenital Radiology decided to review the literature and to issue guidelines. The committee performed a Medline search. Based on this, a report and guidelines were prepared. The report was discussed at the Ninth European Symposium on Urogenital Radiology in Genoa, Italy. Hemodialysis and peritoneal dialysis safely remove both iodinated and gadolinium-based contrast media. The effectiveness of hemodialysis depends on many factors including blood and dialysate flow rate, permeability of dialysis membrane, duration of hemodialysis and molecular size, protein binding, hydrophilicity, and electrical charge of the contrast medium. Generally, several hemodialysis sessions are needed to removal all contrast medium, whereas it takes 3 weeks for continuous ambulatory dialysis to remove the agent completely. There is no need to schedule the dialysis in relation to the injection of iodinated or MR contrast media or the injection of contrast agent in relation to the dialysis program. Hemodialysis does not protect poorly functioning kidneys against contrast-medium-induced nephrotoxicity. Simple guidelines are given. (orig.)

  11. Human pharmacokinetics of iohexol. A new nonionic contrast medium

    International Nuclear Information System (INIS)

    Olsson, B.; Aulie, A.; Sveen, K.; Andrew, E.

    1983-01-01

    The pharmacokinetics of iohexol, a new nonionic, water-soluble contrast medium, have been determined after intravenous injection in 20 healthy volunteers, at four different dose levels (125-500 mg I/kg). The apparent volume of distribution was 0.27 1/kg, indicating distribution in the extracellular water. The biologic half-life was 121 minutes, comparable with that of other intravascular contrast media. Iohexol was excreted completely unmetabolized in the urine, with a 100% recovery 24 hours after injection. A comparison of iohexol and chromium-51 ( 51 Cr)-EDTA clearances indicates that iohexol is mainly excreted by glomerular filtration. The 51 Cr-EDTA clearance was the same when injected separately and concomitantly with iohexol, indicating that glomerular filtration rate is not affected by iohexol. No dose dependency was observed in the investigated parameters t1/2 alpha, t1/2 beta, Vd, ClT or ClR. Iohexol pharmacokinetics are in correspondence with previously reported data on intravascular contrast media

  12. Sleep Dependent Synaptic Down-Selection (II: Single Neuron Level Benefits for Matching, Selectivity, and Specificity

    Directory of Open Access Journals (Sweden)

    Atif eHashmi

    2013-10-01

    Full Text Available In a companion paper (Nere et al., this volume, we used computer simulations to show that a strategy of activity-dependent, on-line net synaptic potentiation during wake, followed by off-line synaptic depression during sleep, can provide a parsimonious account for several memory benefits of sleep at the systems level, including the consolidation of procedural and declarative memories, gist extraction, and integration of new with old memories. In this paper, we consider the theoretical benefits of this two-step process at the single neuron level and employ the theoretical notion of Matching between brain and environment to measure how this process increases the ability of the neuron to capture regularities in the environment and model them internally. We show that down-selection during sleep is beneficial for increasing or restoring Matching after learning, after integrating new with old memories, and after forgetting irrelevant material. By contrast, alternative schemes, such as additional potentiation in wake, potentiation in sleep, or synaptic renormalization in wake, decrease Matching. We also argue that, by selecting appropriate loops through the brain that tie feedforward synapses with feedback ones in the same dendritic domain, different subsets of neurons can learn to specialize for different contingencies and form sequences of nested perception-action loops. By potentiating such loops when interacting with the environment in wake, and depressing them when disconnected from the environment in sleep, neurons can learn to match the long-term statistical structure of the environment while avoiding spurious modes of functioning and catastrophic interference. Finally, such a two-step process has the additional benefit of desaturating the neuron's ability to learn and of maintaining cellular homeostasis. Thus, sleep-dependent synaptic renormalization offers a parsimonious account for both cellular and systems-level effects of sleep on learning

  13. Stroboscopic effect : Contrast threshold function and dependence on illumination level

    NARCIS (Netherlands)

    Perz, M.; Sekulovski, D.; Vogels, I.; Heynderickx, I.

    2018-01-01

    The stroboscopic visibility measure (SVM) is a method used to quantify the stroboscopic effect visibility in general illumination application. SVM has been defined previously based on a limited number of frequencies and participants. To validate and extend SVM, five perception experiments are

  14. Effects of two types of medical contrast media on routine chemistry results by three automated chemistry analyzers.

    Science.gov (United States)

    Park, Yu Jin; Rim, John Hoon; Yim, Jisook; Lee, Sang-Guk; Kim, Jeong-Ho

    2017-08-01

    The use of iodinated contrast media has grown in popularity in the past two decades, but relatively little attention has been paid to the possible interferential effects of contrast media on laboratory test results. Herein, we investigate medical contrast media interference with routine chemistry results obtained by three automated chemistry analyzers. Ten levels of pooled serum were used in the study. Two types of medical contrast media [Iopamiro (iopamidol) and Omnipaque (iohexol)] were evaluated. To evaluate the dose-dependent effects of the contrast media, iopamidol and iohexol were spiked separately into aliquots of serum for final concentrations of 1.8%, 3.6%, 5.5%, 7.3%, and 9.1%. The 28 analytes included in the routine chemistry panel were measured by using Hitachi 7600, AU5800, and Cobas c702 analyzers. We calculated the delta percentage difference (DPD) between the samples and the control, and examined dose-dependent trends. When the mean DPD values were compared with the reference cut-off criteria, the only uniformly interferential effect observed for all analyzers was in total protein with iopamidol. Two additional analytes that showed trends toward interferential effects only in few analyzers and exceeded the limits of the allowable error were the serum iron and the total CO 2 . The other combinations of analyzer and contrast showed no consistent dose-dependent propensity for change in any analyte level. Our study suggests that many of the analytes included in routine chemistry results, except total protein and serum iron, are not significantly affected by iopamidol and iohexol. These results suggest that it would be beneficial to apply a flexible medical evaluation process for patients requiring both laboratory tests and imaging studies, minimizing the need for strict regulations for sequential tests. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  15. Contrast-to-noise ratio optimization for a prototype phase-contrast computed tomography scanner

    International Nuclear Information System (INIS)

    Müller, Mark; Yaroshenko, Andre; Velroyen, Astrid; Tapfer, Arne; Bech, Martin; Pauwels, Bart; Bruyndonckx, Peter; Sasov, Alexander; Pfeiffer, Franz

    2015-01-01

    In the field of biomedical X-ray imaging, novel techniques, such as phase-contrast and dark-field imaging, have the potential to enhance the contrast and provide complementary structural information about a specimen. In this paper, a first prototype of a preclinical X-ray phase-contrast CT scanner based on a Talbot-Lau interferometer is characterized. We present a study of the contrast-to-noise ratios for attenuation and phase-contrast images acquired with the prototype scanner. The shown results are based on a series of projection images and tomographic data sets of a plastic phantom in phase and attenuation-contrast recorded with varying acquisition settings. Subsequently, the signal and noise distribution of different regions in the phantom were determined. We present a novel method for estimation of contrast-to-noise ratios for projection images based on the cylindrical geometry of the phantom. Analytical functions, representing the expected signal in phase and attenuation-contrast for a circular object, are fitted to individual line profiles of the projection data. The free parameter of the fit function is used to estimate the contrast and the goodness of the fit is determined to assess the noise in the respective signal. The results depict the dependence of the contrast-to-noise ratios on the applied source voltages, the number of steps of the phase stepping routine, and the exposure times for an individual step. Moreover, the influence of the number of projection angles on the image quality of CT slices is investigated. Finally, the implications for future imaging purposes with the scanner are discussed

  16. Time varying behavior of the loudspeaker suspension: Displacement level dependency

    DEFF Research Database (Denmark)

    Agerkvist, Finn T.; Pedersen, Bo Rohde

    2009-01-01

    The compliance of the loudspeaker suspension is known to depend on the recent excitation level history. Previous investigations have shown that the electrical power as well as displacement and velocity plays a role. In this paper the hypothesis that the changes in compliance are caused mainly...... by how much the suspension has been stretched, i.e. the maximum displacement, is investigated. For this purpose the changes in compliance are measured when exposing the speaker to different levels and types of electrical excitation signals, as well as mechanical excitation only. For sinusoidal excitation...... the change in compliance is shown to depend primarily on maximum displacement. But for square pulse excitation the duration of the excitation also plays an important role...

  17. Long-range dependence and sea level forecasting

    CERN Document Server

    Ercan, Ali; Abbasov, Rovshan K

    2013-01-01

    This study shows that the Caspian Sea level time series possess long range dependence even after removing linear trends, based on analyses of the Hurst statistic, the sample autocorrelation functions, and the periodogram of the series. Forecasting performance of ARMA, ARIMA, ARFIMA and Trend Line-ARFIMA (TL-ARFIMA) combination models are investigated. The forecast confidence bands and the forecast updating methodology, provided for ARIMA models in the literature, are modified for the ARFIMA models. Sample autocorrelation functions are utilized to estimate the differencing lengths of the ARFIMA

  18. The dependence level analysis between the human actions in NPP Operation

    International Nuclear Information System (INIS)

    Farcasiu, M.; Nitoi, M.; Apostol, M.; Florescu, G.; Prisecaru, Ilie

    2009-01-01

    The Human Reliability Analysis (HRA) is an important method in Probabilistic Safety Assessment (PSA) studies and offers desirability for concrete improvement of the man - machine - organization interfaces, reliability and safety. An important step in HRA is the dependence level analysis between the human actions performed by the same person or between the actions performed by different persons, step in quantitative analysis of the human errors probabilities. The purpose of this paper is to develop a model to analyze the dependence level between human actions for Nuclear Power Plant (NPP) operation. The model estimates the conditional human error probabilities (CHEP) and joint human error probabilities (JHEP). The achieved sensitivity analyses determine human performance sensibility to systematic variations for dependence level between human actions. The human error probabilities estimated in this paper are adequate values for integration both in HRA and in PSA realized for NPP. This type of analysis helps in finding and analyzing the ways of reducing the likelihood of human errors, so that the impact of human factor to systems availability, reliability and safety can be realistically estimated. In order to demonstrate the usability of this model an analysis is performed upon the dependences between the necessary human actions in mitigating the consequences of LOCA events, particularly for the case of Cernavoda NPP. (authors)

  19. Mutant LRRK2 Toxicity in Neurons Depends on LRRK2 Levels and Synuclein But Not Kinase Activity or Inclusion Bodies

    Science.gov (United States)

    Skibinski, Gaia; Nakamura, Ken; Cookson, Mark R.

    2014-01-01

    By combining experimental neuron models and mathematical tools, we developed a “systems” approach to deconvolve cellular mechanisms of neurodegeneration underlying the most common known cause of Parkinson's disease (PD), mutations in leucine-rich repeat kinase 2 (LRRK2). Neurons ectopically expressing mutant LRRK2 formed inclusion bodies (IBs), retracted neurites, accumulated synuclein, and died prematurely, recapitulating key features of PD. Degeneration was predicted from the levels of diffuse mutant LRRK2 that each neuron contained, but IB formation was neither necessary nor sufficient for death. Genetic or pharmacological blockade of its kinase activity destabilized LRRK2 and lowered its levels enough to account for the moderate reduction in LRRK2 toxicity that ensued. By contrast, targeting synuclein, including neurons made from PD patient-derived induced pluripotent cells, dramatically reduced LRRK2-dependent neurodegeneration and LRRK2 levels. These findings suggest that LRRK2 levels are more important than kinase activity per se in predicting toxicity and implicate synuclein as a major mediator of LRRK2-induced neurodegeneration. PMID:24403142

  20. Contextual effects on perceived contrast: figure-ground assignment and orientation contrast.

    Science.gov (United States)

    Self, Matthew W; Mookhoek, Aart; Tjalma, Nienke; Roelfsema, Pieter R

    2015-02-02

    Figure-ground segregation is an important step in the path leading to object recognition. The visual system segregates objects ('figures') in the visual scene from their backgrounds ('ground'). Electrophysiological studies in awake-behaving monkeys have demonstrated that neurons in early visual areas increase their firing rate when responding to a figure compared to responding to the background. We hypothesized that similar changes in neural firing would take place in early visual areas of the human visual system, leading to changes in the perception of low-level visual features. In this study, we investigated whether contrast perception is affected by figure-ground assignment using stimuli similar to those in the electrophysiological studies in monkeys. We measured contrast discrimination thresholds and perceived contrast for Gabor probes placed on figures or the background and found that the perceived contrast of the probe was increased when it was placed on a figure. Furthermore, we tested how this effect compared with the well-known effect of orientation contrast on perceived contrast. We found that figure-ground assignment and orientation contrast produced changes in perceived contrast of a similar magnitude, and that they interacted. Our results demonstrate that figure-ground assignment influences perceived contrast, consistent with an effect of figure-ground assignment on activity in early visual areas of the human visual system. © 2015 ARVO.

  1. Contrasting effects of self-schema priming on lexical decisions and interpersonal stroop task performance: evidence for a cognitive/interactionist model of interpersonal dependency.

    Science.gov (United States)

    Bornstein, Robert F; Ng, H Mei; Gallagher, Heather A; Kloss, Deanna M; Regier, Natalie G

    2005-06-01

    Four experiments tested a key tenet of Bornstein's (1992, 1993) cognitive/interactionist (C/I) model of interpersonal dependency: that priming the helpless self-schema (HSS) alters processing of dependency-related information in dependent--but not nondependent--individuals. Experiments 1 and 2 assessed the effects of subliminal lexical priming and an emotional priming manipulation on lexical decision (LD) judgments for dependency-related words and control words. Experiments 3 and 4 assessed the effects of these same priming procedures on Interpersonal Stroop Task (IST) performance. As predicted, priming the HSS produced contrasting effects on different outcome measures, decreasing LD latencies, but increasing IST response times. Results are discussed in the context of the C/I model, and suggestions for future studies are offered.

  2. Complementary contrast media for metal artifact reduction in dual-energy computed tomography.

    Science.gov (United States)

    Lambert, Jack W; Edic, Peter M; FitzGerald, Paul F; Torres, Andrew S; Yeh, Benjamin M

    2015-07-01

    Metal artifacts have been a problem associated with computed tomography (CT) since its introduction. Recent techniques to mitigate this problem have included utilization of high-energy (keV) virtual monochromatic spectral (VMS) images, produced via dual-energy CT (DECT). A problem with these high-keV images is that contrast enhancement provided by all commercially available contrast media is severely reduced. Contrast agents based on higher atomic number elements can maintain contrast at the higher energy levels where artifacts are reduced. This study evaluated three such candidate elements: bismuth, tantalum, and tungsten, as well as two conventional contrast elements: iodine and barium. A water-based phantom with vials containing these five elements in solution, as well as different artifact-producing metal structures, was scanned with a DECT scanner capable of rapid operating voltage switching. In the VMS datasets, substantial reductions in the contrast were observed for iodine and barium, which suffered from contrast reductions of 97% and 91%, respectively, at 140 versus 40 keV. In comparison under the same conditions, the candidate agents demonstrated contrast enhancement reductions of only 20%, 29%, and 32% for tungsten, tantalum, and bismuth, respectively. At 140 versus 40 keV, metal artifact severity was reduced by 57% to 85% depending on the phantom configuration.

  3. DEPENDENCE OF THE SPECKLE-PATTERNS SIZE AND THEIR CONTRAST ON THE BIOPHYSICAL AND STRUCTURAL PARAMETERS OF BIOLOGICAL TISSUES

    Directory of Open Access Journals (Sweden)

    N. D. Abramovich

    2017-01-01

    Full Text Available Speckle fields are widely used in optical diagnostics of biotissues and evaluation of the functional state of bioobjects. The speckle field is formed by laser radiation scattered from the object under study. It bears information about the average dimensions of the scatterers, the degree of surface roughness makes it possible to judge the structural and biophysical characteristics of individual tissue cells (particles, on the one hand, and the integral optical characteristics of the entire biological tissue. The aim of the study was – the determination of connections between the biophysical and structural characteristics of the biotissue and the light fields inside the biotissues.The model developed of the medium gives a direct relationship between the optical and biophysical parameters of the biotissue. Calculations were carried out using known solutions of the radiation transfer equation, taking into account the multilayer structure of the tissue, multiple scattering in the medium, and multiple reflection of irradiation between the layers.With the increase wavelength, the size of speckles formed by the non-scattered component (direct light of laser radiation increases by a factor of 2 from 400 to 800 μm in the stratum corneum and 5 times from 0.6 to 3 μm for the epidermis and from 0.27 to 1.4 μm to the dermis. Typical values of sizes of speckles formed by the diffraction component of laser radiation for the stratum corneum and epidermis range from 0.02 to 0.15 μm. For the dermis typical spot sizes are up to 0.03 μm. The speckle-spot size of the diffusion component in the dermis can vary from ±10 % at 400 nm and up to ±23 % for 800 nm when the volume concentration of blood capillaries changes. Characteristic dependencies are obtained and biophysical factors associated with the volume concentration of blood and the degree of it’s oxygenation that affect the contrast of the speckle structure in the dermis are discussed.The of speckles

  4. Low-level contrast statistics of natural images can modulate the frequency of event-related potentials (ERP in humans

    Directory of Open Access Journals (Sweden)

    Masoud Ghodrati

    2016-12-01

    Full Text Available Humans are fast and accurate in categorizing complex natural images. It is, however, unclear what features of visual information are exploited by brain to perceive the images with such speed and accuracy. It has been shown that low-level contrast statistics of natural scenes can explain the variance of amplitude of event-related potentials (ERP in response to rapidly presented images. In this study, we investigated the effect of these statistics on frequency content of ERPs. We recorded ERPs from human subjects, while they viewed natural images each presented for 70 ms. Our results showed that Weibull contrast statistics, as a biologically plausible model, explained the variance of ERPs the best, compared to other image statistics that we assessed. Our time-frequency analysis revealed a significant correlation between these statistics and ERPs’ power within theta frequency band (~3-7 Hz. This is interesting, as theta band is believed to be involved in context updating and semantic encoding. This correlation became significant at ~110 ms after stimulus onset, and peaked at 138 ms. Our results show that not only the amplitude but also the frequency of neural responses can be modulated with low-level contrast statistics of natural images and highlights their potential role in scene perception.

  5. Dependence centrality similarity: Measuring the diversity of profession levels of interests

    Science.gov (United States)

    Yan, Deng-Cheng; Li, Ming; Wang, Bing-Hong

    2017-08-01

    To understand the relations between developers and software, we study a collaborative coding platform from the perspective of networks, including follower networks, dependence networks and developer-project bipartite networks. Through the analyzing of degree distribution, PageRank and degree-dependent nearest neighbors' centrality, we find that the degree distributions of all networks have a power-law form except the out-degree distributions of dependence networks. The nearest neighbors' centrality is negatively correlated with degree for developers but fluctuates around the average for projects. In order to measure the diversity of profession levels of interests, a new index called dependence centrality similarity is proposed and the correlation between dependence centrality similarity and degree is investigated. The result shows an obvious negative correlations between dependence centrality similarity and degree.

  6. Contrasting records of sea-level change in the eastern and western North Atlantic during the last 300 years

    Science.gov (United States)

    Long, A. J.; Barlow, N. L. M.; Gehrels, W. R.; Saher, M. H.; Woodworth, P. L.; Scaife, R. G.; Brain, M. J.; Cahill, N.

    2014-02-01

    We present a new 300-year sea-level reconstruction from a salt marsh on the Isle of Wight (central English Channel, UK) that we compare to other salt-marsh and long tide-gauge records to examine spatial and temporal variability in sea-level change in the North Atlantic. Our new reconstruction identifies an overall rise in relative sea level (RSL) of c. 0.30 m since the start of the eighteenth century at a rate of 0.9±0.3 mm yr. Error-in-variables changepoint analysis indicates that there is no statistically significant deviation from a constant rate within the dataset. The reconstruction is broadly comparable to other tide-gauge and salt-marsh records from the European Atlantic, demonstrating coherence in sea level in this region over the last 150-300 years. In contrast, we identify significant differences in the rate and timing of RSL with records from the east coast of North America. The absence of a strong late 19th/early 20th century RSL acceleration contrasts with that recorded in salt marsh sediments along the eastern USA coastline, in particular in a well-dated and precise sea-level reconstruction from North Carolina. This suggests that this part of the North Carolina sea level record represents a regionally specific sea level acceleration. This is significant because the North Carolina record has been used as if it were globally representative within semi-empirical parameterisations of past and future sea-level change. We conclude that regional-scale differences of sea-level change highlight the value of using several, regionally representative RSL records when calibrating and testing semi-empirical models of sea level against palaeo-records. This is because by using records that potentially over-estimate sea-level rise in the past such models risk over-estimating sea-level rise in the future.

  7. The pathological status of exercise dependence

    Science.gov (United States)

    Bamber, D.; Cockerill, I.; Carroll, D.

    2000-01-01

    Objectives—This study was concerned with the concept of exercise dependence. Levels of psychological morbidity, personality profiles, and exercise beliefs were compared among subjects screened for exercise dependence and eating disorders. Method—Adult female exercisers were allocated on the basis of questionnaire screening to one of the following groups: primary exercise dependence (n = 43); secondary exercise dependence, where there was the coincidence of exercise dependence and an eating disorder (n = 27); eating disorder (n =14); control, where there was no evidence of either exercise dependence or eating disorder (n = 110). Questionnaire assessment was undertaken of psychological morbidity, self esteem, weight and body shape dissatisfaction, personality, and exercise beliefs. Results—Aside from a higher incidence of reported menstrual abnormalities, the primary exercise dependence group was largely indistinguishable from the controls. In stark contrast, the secondary exercise dependence group reported higher levels of psychological morbidity, neuroticism, dispositional addictiveness, and impulsiveness, lower self esteem, greater concern with body shape and weight, as well as with the social, psychological, and aesthetic costs of not exercising than the controls, but differed little from the eating disorder group. Conclusions—In the absence of an eating disorder, women identified as being exercise dependent do not exhibit the sorts of personality characteristics and levels of psychological distress that warrant the construction of primary exercise dependence as a widespread pathology. Key Words: exercise dependence; eating disorders; personality; self esteem; neuroticism; psychological morbidity PMID:10786869

  8. Iodinated contrast media nephrotoxicity. Nephrotoxicite des produits de contraste iodes

    Energy Technology Data Exchange (ETDEWEB)

    Meyrier, A. (Hopital Avicenne, 93 - Bobigny (France))

    1994-01-01

    In the late seventies, iodinated contrast agents (ICA) were considered to be a major cause of acute iatrogenic renal failure. Over the last decade new contrast agents have been synthesized, nonionic and less hyperosmolar. The incidence of acute renal failure due to ICAs, varies from 3.7 to 70% of cases according to the series, with an average figure of 10.2%. The pathophysiology of ICA nephrotoxicity was mainly studied in laboratory animal models. Three main factors are involved in an inducing ICA-mediated decrease in glomerular filtration rate: reduction of the renal plasma flow, a direct cytotoxic effect on renal tubular cells and erythrocyte alteration leading to intra-renal sludge. Excluding dysglobulinemias with urinary excretion of immunoglobulin light chains, which represent a special case of maximum nephrotoxicity, 4 main risk factors of renal toxicity have been identified in nondiabetic subjects: previous renal failure with serum creatinine levels greater than 140 [mu]mol per liter, extracellular dehydration, age over 60 and use of high doses of ICA and/or repeated ICA injections before serum creatinine levels return to baseline. Preventive measures for avoiding ICA nephrotoxicity are threefold: maintain or restore adequate hydration with saline infusion, stop NSAID treatment several days before ICA administration, and allow a 5 day interval before repeating contrast media injections. New, nonionic and moderately hyperosmolar contrast agents appear to be much less nephrotoxic than conventional ICAs in laboratory animals and in high-risk patients. It is advisable to select such contrast media for investigating high-risk patients. This approach was recently substantiated in well designed, randomized clinical studies which included more than 2 000 patients. (author).

  9. Effects of luminance contrast and its modifications on fixation behavior during free viewing of images from different categories.

    Science.gov (United States)

    Açik, Alper; Onat, Selim; Schumann, Frank; Einhäuser, Wolfgang; König, Peter

    2009-06-01

    During viewing of natural scenes, do low-level features guide attention, and if so, does this depend on higher-level features? To answer these questions, we studied the image category dependence of low-level feature modification effects. Subjects fixated contrast-modified regions often in natural scene images, while smaller but significant effects were observed for urban scenes and faces. Surprisingly, modifications in fractal images did not influence fixations. Further analysis revealed an inverse relationship between modification effects and higher-level, phase-dependent image features. We suggest that high- and mid-level features--such as edges, symmetries, and recursive patterns--guide attention if present. However, if the scene lacks such diagnostic properties, low-level features prevail. We posit a hierarchical framework, which combines aspects of bottom-up and top-down theories and is compatible with our data.

  10. Angular momentum dependence of the nuclear level density parameter

    International Nuclear Information System (INIS)

    Aggarwal, Mamta; Kailas, S.

    2010-01-01

    Dependence of nuclear level density parameter on the angular momentum and temperature is investigated in a theoretical framework using the statistical theory of hot rotating nuclei. The structural effects are incorporated by including shell correction, shape, and deformation. The nuclei around Z≅50 with an excitation energy range of 30 to 40 MeV are considered. The calculations are in good agreement with the experimentally deduced inverse level density parameter values especially for 109 In, 113 Sb, 122 Te, 123 I, and 127 Cs nuclei.

  11. Contrast Enhanced US in the Abdomen

    International Nuclear Information System (INIS)

    Chung, Yong Eun; Kim, Ki Whang

    2012-01-01

    Contrast enhanced ultrasound, which was introduced in 1996, has been widely used in Europe and Eastern Asia. Ultrasound contrast agent can be classified as first generation and second generation, depending on the gas within the microbubble. With the first generation contrast agent, the high MI technique was used, and only intermittent scanning was possible due to destruction of the microbubble during scanning. Use of the second generation contrast agent with the low MI technique makes continuous scanning possible. Contrast enhanced US can be used in detection and differentiation of focal liver lesions. It is also helpful for monitoring of radiofrequency ablation and for targeting of US guided biopsy. Currently, because morphologic criteria alone may not reflect the response of the tumor to treatment, new criteria are needed for treatment evaluation after administration of anti-angiogenic agents. Contrast enhanced US could provide quantitative markers for evaluation of the response to treatment via use of dynamic contrast enhanced US. Due to cost-effectiveness, contrast enhanced US is not yet widely used in Korea; however, considering recent issues regarding contrast agent related adverse reaction, such as contrast induced nephropathy and nephrogenic systemic fibrosis, and radiation exposure, contrast enhanced US might be more widely used in Korea, as an alternative imaging modality in the future.

  12. A Busy period analysis of the level dependent PH/PH/1/K queue

    NARCIS (Netherlands)

    Al Hanbali, Ahmad

    2011-01-01

    In this paper, we study the transient behavior of a level dependent single server queuing system with a waiting room of finite size during the busy period. The focus is on the level dependent PH/PH/1/K queue. We derive in closed form the joint transform of the length of the busy period, the number

  13. Nicotine Dependence and Urinary Nicotine, Cotinine and Hydroxycotinine Levels in Daily Smokers.

    Science.gov (United States)

    Van Overmeire, Ilse P I; De Smedt, Tom; Dendale, Paul; Nackaerts, Kristiaan; Vanacker, Hilde; Vanoeteren, Jan F A; Van Laethem, Danny M G; Van Loco, Joris; De Cremer, Koen A J

    2016-09-01

    Nicotine dependence and smoking frequency are critical factors for smoking cessation. The aims of this study are (1) to determine if nicotine dependence Fagerström Test for Nicotine Dependence (FTND) scores are associated with urinary levels of nicotine metabolites, (2) to assess the relationship of hydroxycotinine/cotinine ratio with FTND score and cigarettes smoked per day (CPD), and (3) to identify significant predictors of cigarettes per day among biomarker concentrations and individual FTND items. Urine samples and questionnaire data of 239 daily smokers were obtained. Nicotine, cotinine and hydroxycotinine urinary levels were determined by UPLC MS/MS.Multiple linear regression models were developed to explore the relationship between nicotine, cotinine, hydroxycotinine levels and separate FTND scores (for all six items). We found significant correlations between the different urinary biomarker concentrations, and the FTND score. The time before the first cigarette after waking (TTFC) was significantly associated with the nicotine, cotinine and hydroxycotinine concentrations. No association was found between the ratio of hydroxycotinine to cotinine and either the FTND or the CPD. A model including four FTND questions, sex, age, and the cotinine concentration, accounted for 45% of the variance of CPD. There are significant relationships between urinary levels of nicotine, cotinine, and hydroxycotinine and the FTND score. Especially the FTND question about TTFC is relevant for explaining the biomarker concentrations. CPD (below 15) was significantly explained by four FTND dependence items and urinary cotinine levels in a regression model. We investigated associations between urinary levels of nicotine, cotinine, and hydroxycotinine in daily smokers and the FTND scores for nicotine dependence. We did not find association between the hydroxycotinine/cotinine ratio and CPD. We developed a model that explains the cigarettes smoked daily (CPD) in a group of light

  14. Generalized image contrast enhancement technique based on Heinemann contrast discrimination model

    Science.gov (United States)

    Liu, Hong; Nodine, Calvin F.

    1994-03-01

    This paper presents a generalized image contrast enhancement technique which equalizes perceived brightness based on the Heinemann contrast discrimination model. This is a modified algorithm which presents an improvement over the previous study by Mokrane in its mathematically proven existence of a unique solution and in its easily tunable parameterization. The model uses a log-log representation of contrast luminosity between targets and the surround in a fixed luminosity background setting. The algorithm consists of two nonlinear gray-scale mapping functions which have seven parameters, two of which are adjustable Heinemann constants. Another parameter is the background gray level. The remaining four parameters are nonlinear functions of gray scale distribution of the image, and can be uniquely determined once the previous three are given. Tests have been carried out to examine the effectiveness of the algorithm for increasing the overall contrast of images. It can be demonstrated that the generalized algorithm provides better contrast enhancement than histogram equalization. In fact, the histogram equalization technique is a special case of the proposed mapping.

  15. Dependency of high coastal water level and river discharge at the global scale

    Science.gov (United States)

    Ward, P.; Couasnon, A.; Haigh, I. D.; Muis, S.; Veldkamp, T.; Winsemius, H.; Wahl, T.

    2017-12-01

    It is widely recognized that floods cause huge socioeconomic impacts. From 1980-2013, global flood losses exceeded $1 trillion, with 220,000 fatalities. These impacts are particularly hard felt in low-lying densely populated deltas and estuaries, whose location at the coast-land interface makes them naturally prone to flooding. When river and coastal floods coincide, their impacts in these deltas and estuaries are often worse than when they occur in isolation. Such floods are examples of so-called `compound events'. In this contribution, we present the first global scale analysis of the statistical dependency of high coastal water levels (and the storm surge component alone) and river discharge. We show that there is statistical dependency between these components at more than half of the stations examined. We also show time-lags in the highest correlation between peak discharges and coastal water levels. Finally, we assess the probability of the simultaneous occurrence of design discharge and design coastal water levels, assuming both independence and statistical dependence. For those stations where we identified statistical dependency, the probability is between 1 and 5 times greater, when the dependence structure is accounted for. This information is essential for understanding the likelihood of compound flood events occurring at locations around the world as well as for accurate flood risk assessments and effective flood risk management. The research was carried out by analysing the statistical dependency between observed coastal water levels (and the storm surge component) from GESLA-2 and river discharge using gauged data from GRDC stations all around the world. The dependence structure was examined using copula functions.

  16. Visibility of minute objects with low contrast

    International Nuclear Information System (INIS)

    Sato, Nobuo

    1982-01-01

    Minimum perceptible contrast was obtained with a penetrameter made of aluminum plates, in which 40 very small holes were perforated. An object can be seen when its contrast exceeds the minimum perceptible contrast. Visual threshold contrast ratio offers minimum perceptible diameter (MPD) which is theoretically obtained from an image contrast corresponding to the technique applied. The MPDs were obtained prior to experiment as a function of system speed, beam quality, exposure range and magnification, which resulted in a reasonable agreement with the experimental results. The visibility of small dot-like objects depends on the granularity as its threshold is governed by the surrounding grainy noise. However it was revealed that MTF was as important as granularity. Dot and lineshaped objects were simulated with small glass beads and nylon fibrils, respectively, in order to make ROC analysis on the different radiographic techniques with a CGR Senograph 500T mammographic unit. The 1.5X magnification technique showed the largest advantage on phantom work basis, but clinical evaluation showed the different weight of the affecting physical factors. The results of ROC analysis were extended to entropy analysis. The visibility in actual mammography depends upon the acutance of images as Xeroradiography proved. (Kako, I.)

  17. [Measuring contrast sensitivity using visual acuity tests in retinal and optic nerve diseases].

    Science.gov (United States)

    Sommer, E; Marré, E; Mierdel, P

    1990-01-01

    The luminance contrast needed to discern various test types was measured with monochromatic and achromatic light to detect discrete functional deficiencies of the retina and optic nerve in cases of normal visual acuity. Landolt rings corresponding to visual acuity levels from 0.04 to 1.0 were used as test types. A significant increase in the necessary minimum contrast was detectable with blue test light on large Landolt rings in patients with diabetic retinopathy, ocular hypertension and glaucoma and with green or yellow test light on medium-sized and small Landolt rings in patients with central serous chorioidopathy and optic atrophy. The additional contrast needed to reach the maximum visual acuity amounts to 14-100% compared with normal visual acuity, depending on the color of the test light and the diagnosis. The amount of contrast needed is greatest in retinal diseases, and it is therefore possible to a certain extent to distinguish these from diseases of the optic nerve.

  18. Letter contrast sensitivity function of the eye.

    Science.gov (United States)

    Liou, H L; Brennan, N A

    1998-06-01

    To provide empirical data of letter CSF for various levels of defocus under controlled conditions of luminance and age. Corrected distance visual acuities were tested at different levels of contrast and defocus. An experiment was conducted using the Medmont visual acuity tester on 10 young subjects and under normal room lighting. Empirical data of visual acuity were obtained for 7 levels of contrast (5, 10, 15, 25, 40, 60, 80%) and defocus levels of 0, +1 and +2D. A mathematical model was derived (R2=0.995) and this can be used to estimate visual acuity at various contrast levels for defocus of < or =+2D. This information is useful for the clinician as normative data and for further development of optical models to predict visual performance of the eye.

  19. Dependence levels in users of electronic cigarettes, nicotine gums and tobacco cigarettes.

    Science.gov (United States)

    Etter, Jean-François; Eissenberg, Thomas

    2015-02-01

    To assess dependence levels in users of e-cigarettes, and compare them with dependence levels in users of nicotine gums and tobacco cigarettes. Self-reports from cross-sectional Internet and mail surveys. Comparisons of: (a) 766 daily users of nicotine-containing e-cigarettes with 30 daily users of nicotine-free e-cigarettes; (b) 911 former smokers who used the e-cigarette daily with 451 former smokers who used the nicotine gum daily (but no e-cigarette); (c) 125 daily e-cigarette users who smoked daily (dual users) with two samples of daily smokers who did not use e-cigarettes (2206 enrolled on the Internet and 292 enrolled by mail from the general population of Geneva). We used the Fagerström test for nicotine dependence, the nicotine dependence syndrome scale, the cigarette dependence scale and versions of these scales adapted for e-cigarettes and nicotine gums. Dependence ratings were slightly higher in users of nicotine-containing e-cigarettes than in users of nicotine-free e-cigarettes. In former smokers, long-term (>3 months) users of e-cigarettes were less dependent on e-cigarettes than long-term users of the nicotine gum were dependent on the gum. There were few differences in dependence ratings between short-term (≤3 months) users of gums or e-cigarettes. Dependence on e-cigarettes was generally lower in dual users than dependence on tobacco cigarettes in the two other samples of daily smokers. Some e-cigarette users were dependent on nicotine-containing e-cigarettes, but these products were less addictive than tobacco cigarettes. E-cigarettes may be as or less addictive than nicotine gums, which themselves are not very addictive. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  20. The contrasting responses of soil microorganisms in two rice cultivars to elevated ground-level ozone

    International Nuclear Information System (INIS)

    Feng, Youzhi; Yu, Yongjie; Tang, Haoye; Zu, Qianhui; Zhu, Jianguo; Lin, Xiangui

    2015-01-01

    Although elevated ground-level O 3 has a species–specific impact on plant growth, the differences in soil biota responses to O 3 pollution among rice cultivars are rarely reported. Using O 3 Free-Air Concentration Enrichment, the responses of the rhizospheric bacterial communities in the O 3 -tolerant (YD6) and the O 3 -sensitive (IIY084) rice cultivars to O 3 pollution and their differences were assessed by pyrosequencing at rice tillering and anthesis stages. Elevated ground-level O 3 negatively influenced the bacterial community in cultivar YD6 at both rice growth stages by decreasing the bacterial phylogenetic diversities and response ratios. In contrast, in cultivar IIY084, the bacterial community responded positively at the rice tillering stage under O 3 pollution. However, several keystone bacterial guilds were consistently negatively affected by O 3 pollution in two rice cultivars. These findings indicate that continuously O 3 pollution would negatively influence rice agroecosystem and the crop cultivar is important in determining the soil biota responses to elevated O 3 . - Highlights: • We investigated the soil biota in two rice cultivars in presence of elevated O 3 . • The contrasting responses of soil biota were found between two rice cultivars. • Some keystone bacterial guilds were consistently negatively affected by O 3 pollution. • The crop cultivar is important in determining soil biota responses to elevated O 3 . - The crop cultivar is important in determining the soil biota responses to elevated O 3

  1. Temperature dependent energy levels of methylammonium lead iodide perovskite

    Science.gov (United States)

    Foley, Benjamin J.; Marlowe, Daniel L.; Sun, Keye; Saidi, Wissam A.; Scudiero, Louis; Gupta, Mool C.; Choi, Joshua J.

    2015-06-01

    Temperature dependent energy levels of methylammonium lead iodide are investigated using a combination of ultraviolet photoemission spectroscopy and optical spectroscopy. Our results show that the valence band maximum and conduction band minimum shift down in energy by 110 meV and 77 meV as temperature increases from 28 °C to 85 °C. Density functional theory calculations using slab structures show that the decreased orbital splitting due to thermal expansion is a major contribution to the experimentally observed shift in energy levels. Our results have implications for solar cell performance under operating conditions with continued sunlight exposure and increased temperature.

  2. Contrast media induced acute renal failure in diabetics

    International Nuclear Information System (INIS)

    Rambausek, M.

    1985-01-01

    Dehydration, preexisting renal insufficiency, multiple myeloma and insulin-dependent diabetes mellitus are known risk factors for a radiocontrast medium induced acute renal failure. In 90% of patients with insulin-dependent diabetes mellitus, renal insufficiency and proteinuria, a further detoriation of renal function can be expected after i.v. administration of radiocontrast medium. Recent concepts on the genesis of acute renal failure after radiocontrast medium in multiple myeloma emphasize the role of tubular blocade (tubular precipitation of myeloma protein with contrast medium). In insulin-dependent diabetic patients we found altered carbohydrate composition of urinary Tamm Horsfall Protein (THP), with increased glucose and diminished N-acetyl-neuraminicacid content. This was paralleled by a difference in an in-vitro system of coprecipitation where THP of diabetes triggered more pronounced calcium dependent coprecipitation of contrast medium and albumin. These in-vitro findings might be important for the explanation of the genesis of radiocontrast medium-induced acute renal failure in insulin-dependent diabetes mellitus. (orig.) [de

  3. Effect of luminance contrast on BOLD-fMRI response in deaf and normal occipital visual cortex

    International Nuclear Information System (INIS)

    Xue Yanping; Zhai Renyou; Jiang Tao; Cui Yong; Zhou Tiangang; Rao Hengyi; Zhuo Yan

    2002-01-01

    Objective: To examine the effect of luminance contrast stimulus by using blood oxygenation level dependent functional magnetic resonance imaging (BOLD-fMRI) within deaf occipital visual cortex, and to compare the distribution, extent, and intensity of activated areas between deaf subjects and normal hearing subjects. Methods: Twelve deaf subjects (average age 16.5) and 15 normal hearing subjects (average age 23.7) were stimulated by 4 kinds of luminance contrast (0.7, 2.2, 50.0, 180.0 lm). The fMRI data were collected on GE 1.5 T Signa Horizon LX MRI system and analyzed by AFNI to generate the activation map. Results: Responding to all 4 kinds of stimulus luminance contrast, all deaf and normal subjects showed significant activations in occipital visual cortex. For both deaf and normal subjects, the number of activated pixels increased significantly with increasing luminance contrast (F normal = 4.27, P deaf = 6.41, P 0.05). The local mean activation level for all activated pixels remained constant with increasing luminance contrast. However, there was an increase in the mean activation level for those activated pixels common to all trials as the stimulus luminance contrast was increased, but no significant difference was found within them (F normal = 0.79, P > 0.05; F deaf = 1.6, P > 0.05). Conclusion: The effect of luminance contrast on occipital visual cortex of deaf is similar to but somewhat higher than that of normal hearing subjects. In addition, it also proved that fMRI is a feasible method in the study of the deaf visual cortex

  4. Nicotine Dependence and Urinary Nicotine, Cotinine and Hydroxycotinine Levels in Daily Smokers

    OpenAIRE

    Van Overmeire, Ilse P. I.; De Smedt, Tom; Dendale, Paul; Nackaerts, Kristiaan; Vanacker, Hilde; Vanoeteren, Jan F. A.; Van Laethem, Danny M. G.; Van Loco, Joris; De Cremer, Koen A. J.

    2016-01-01

    Nicotine dependence and smoking frequency are critical factors for smoking cessation. The aims of this study are (1) to determine if nicotine dependence Fagerstrom Test for Nicotine Dependence (FTND) scores are associated with urinary levels of nicotine metabolites, (2) to assess the relationship of hydroxycotinine/cotinine ratio with FTND score and cigarettes smoked per day (CPD), and (3) to identify significant predictors of cigarettes per day among biomarker concentrations and individual F...

  5. Low contrast volume run-off CT angiography with optimized scan time based on double-level test bolus technique – feasibility study

    International Nuclear Information System (INIS)

    Baxa, Jan; Vendiš, Tomáš; Moláček, Jiří; Štěpánková, Lucie; Flohr, Thomas; Schmidt, Bernhard; Korporaal, Johannes G.; Ferda, Jiří

    2014-01-01

    Purpose: To verify the technical feasibility of low contrast volume (40 mL) run-off CT angiography (run-off CTA) with the individual scan time optimization based on double-level test bolus technique. Materials and methods: A prospective study of 92 consecutive patients who underwent run-off CTA performed with 40 mL of contrast medium (injection rate of 6 mL/s) and optimized scan times on a second generation of dual-source CT. Individual optimized scan times were calculated from aortopopliteal transit times obtained on the basis of double-level test bolus technique – the single injection of 10 mL test bolus and dynamic acquisitions in two levels (abdominal aorta and popliteal arteries). Intraluminal attenuation (HU) was measured in 6 levels (aorta, iliac, femoral and popliteal arteries, middle and distal lower-legs) and subjective quality (3-point score) was assessed. Relations of image quality, test bolus parameters and arterial circulation involvement were analyzed. Results: High mean attenuation (HU) values (468; 437; 442; 440; 342; 274) and quality score in all monitored levels was achieved. In 91 patients (0.99) the sufficient diagnostic quality (score 1–2) in aorta, iliac and femoral arteries was determined. A total of 6 patients (0.07) were not evaluable in distal lower-legs. Only the weak indirect correlation of image quality and test-bolus parameters was proved in iliac, femoral and popliteal levels (r values: −0.263, −0.298 and −0.254). The statistically significant difference of the test-bolus parameters and image quality was proved in patients with occlusive and aneurysmal disease. Conclusion: We proved the technical feasibility and sufficient quality of run-off CTA with low volume of contrast medium and optimized scan time according to aortopopliteal transit time calculated from double-level test bolus

  6. Influence of radiographic contrast media on phagocytosis

    International Nuclear Information System (INIS)

    Rasmussen, F.; Georgsen, J.; Grunnet, N.; Aalborg Sygehus

    1988-01-01

    To evaluate the influence of radiographic contrast media (CM) on human polymorphonuclear leucocytes (PML), the ability of these cells to ingest latex particles after in vitro exposure to five different radiographic contrast media was investigated. All CM inhibited the phagocytic properties of PML. The inhibition was dose dependent. The inhibitory effect was partly due to hyperosmolality but CM specific inhibition was also evident. (orig.)

  7. Simultaneous reflection masking: dependency on direct sound level and hearing-impairment

    DEFF Research Database (Denmark)

    Buchholz, Jörg; Mihai, Paul Glad

    2008-01-01

    B-SL direct sound level, NH-listeners showed a binaural suppression effect for delays smaller than 7-10 ms and a binaural enhancement effect for larger delays. When decreasing the direct sound level to 15 dB-SL, the only significant change observed was that the dichotic RMT increased for delays larger than...... expected from changed auditory filter bandwidth and audi-bility. However, the stimulus level-dependency of the auditory filters’ bandwidth was not reflected in the SRMT data....

  8. Differential gene expression of wheat progeny with contrasting levels of transpiration efficiency.

    Science.gov (United States)

    Xue, Gang-Ping; McIntyre, C Lynne; Chapman, Scott; Bower, Neil I; Way, Heather; Reverter, Antonio; Clarke, Bryan; Shorter, Ray

    2006-08-01

    High water use efficiency or transpiration efficiency (TE) in wheat is a desirable physiological trait for increasing grain yield under water-limited environments. The identification of genes associated with this trait would facilitate the selection for genotypes with higher TE using molecular markers. We performed an expression profiling (microarray) analysis of approximately 16,000 unique wheat ESTs to identify genes that were differentially expressed between wheat progeny lines with contrasting TE levels from a cross between Quarrion (high TE) and Genaro 81 (low TE). We also conducted a second microarray analysis to identify genes responsive to drought stress in wheat leaves. Ninety-three genes that were differentially expressed between high and low TE progeny lines were identified. One fifth of these genes were markedly responsive to drought stress. Several potential growth-related regulatory genes, which were down-regulated by drought, were expressed at a higher level in the high TE lines than the low TE lines and are potentially associated with a biomass production component of the Quarrion-derived high TE trait. Eighteen of the TE differentially expressed genes were further analysed using quantitative RT-PCR on a separate set of plant samples from those used for microarray analysis. The expression levels of 11 of the 18 genes were positively correlated with the high TE trait, measured as carbon isotope discrimination (Delta(13)C). These data indicate that some of these TE differentially expressed genes are candidates for investigating processes that underlie the high TE trait or for use as expression quantitative trait loci (eQTLs) for TE.

  9. Contrasting patterns of comprehension for superordinate, basic-level, and subordinate names in semantic dementia and aphasic stroke patients.

    Science.gov (United States)

    Crutch, Sebastian J; Warrington, Elizabeth K

    2008-06-01

    It is well established that patients with semantic memory impairment show a relative sparing of general superordinate information as compared with more detailed item-specific information. The objective of the current study was to examine whether or not this superordinate superiority effect is also reliably observed in individuals with stroke. The participants were 3 patients with a diagnosis of semantic dementia (SD) and 4 left middle cerebral artery stroke patients. In the first experiment, participants were administered a series of spoken-word-picture matching tasks, in which picture identity was probed under two conditions: item name (e.g., goose, beetle, shark, hedgehog) and superordinate name (e.g., bird, insect, fish, mammal). The SD patients showed the predicted pattern of performance, identifying stimuli significantly more accurately by their superordinate term than by their specific name. By contrast, the stroke patients showed the reverse pattern of inferior performance in the superordinate condition in all versions of the experimental task. In a second experiment comparing comprehension ofbasic-level names (e.g., dog, bird, fish) and subordinate-level names (e.g., Dalmatian, sparrow, trout), stroke patients also showed a reversal of the normal basic-level effect, showing less accurate comprehension of basic-level names. The pattern of results documented among the stroke patients cannot be accommodated obviously or readily by existing models of conceptual knowledge. These contrasting abilities of SD patients, stroke patients, and normal healthy participants to process subordinate, basic-level, and superordinate names are considered in relation to disorders of executive processing and taxonomic categorization.

  10. Temperature dependent energy levels of methylammonium lead iodide perovskite

    Energy Technology Data Exchange (ETDEWEB)

    Foley, Benjamin J.; Marlowe, Daniel L.; Choi, Joshua J., E-mail: jjc6z@virginia.edu, E-mail: mgupta@virginia.edu, E-mail: scudiero@wsu.edu [Department of Chemical Engineering, University of Virginia, Charlottesville, Virginia 22904 (United States); Sun, Keye; Gupta, Mool C., E-mail: jjc6z@virginia.edu, E-mail: mgupta@virginia.edu, E-mail: scudiero@wsu.edu [Department of Electrical and Computer Engineering, University of Virginia, Charlottesville, Virginia 22904 (United States); Saidi, Wissam A. [Department of Mechanical Engineering and Materials Science, University of Pittsburgh, Pittsburgh, Pennsylvania 15261 (United States); Scudiero, Louis, E-mail: jjc6z@virginia.edu, E-mail: mgupta@virginia.edu, E-mail: scudiero@wsu.edu [Chemistry Department and Materials Science and Engineering Program, Washington State University, Pullman, Washington 99164 (United States)

    2015-06-15

    Temperature dependent energy levels of methylammonium lead iodide are investigated using a combination of ultraviolet photoemission spectroscopy and optical spectroscopy. Our results show that the valence band maximum and conduction band minimum shift down in energy by 110 meV and 77 meV as temperature increases from 28 °C to 85 °C. Density functional theory calculations using slab structures show that the decreased orbital splitting due to thermal expansion is a major contribution to the experimentally observed shift in energy levels. Our results have implications for solar cell performance under operating conditions with continued sunlight exposure and increased temperature.

  11. Nuclear level density parameter 's dependence on angular momentum

    International Nuclear Information System (INIS)

    Aggarwal, Mamta; Kailas, S.

    2009-01-01

    Nuclear level densities represent a very important ingredient in the statistical Model calculations of nuclear reaction cross sections and help to understand the microscopic features of the excited nuclei. Most of the earlier experimental nuclear level density measurements are confined to low excitation energy and low spin region. A recent experimental investigation of nuclear level densities in high excitation energy and angular momentum domain with some interesting results on inverse level density parameter's dependence on angular momentum in the region around Z=50 has motivated us to study and analyse these experimental results in a microscopic theoretical framework. In the experiment, heavy ion fusion reactions are used to populate the excited and rotating nuclei and measured the α particle evaporation spectra in coincidence with ray multiplicity. Residual nuclei are in the range of Z R 48-55 with excitation energy range 30 to 40 MeV and angular momentum in 10 to 25. The inverse level density parameter K is found to be in the range of 9.0 - 10.5 with some exceptions

  12. Multi-level tree analysis of pulmonary artery/vein trees in non-contrast CT images

    Science.gov (United States)

    Gao, Zhiyun; Grout, Randall W.; Hoffman, Eric A.; Saha, Punam K.

    2012-02-01

    Diseases like pulmonary embolism and pulmonary hypertension are associated with vascular dystrophy. Identifying such pulmonary artery/vein (A/V) tree dystrophy in terms of quantitative measures via CT imaging significantly facilitates early detection of disease or a treatment monitoring process. A tree structure, consisting of nodes and connected arcs, linked to the volumetric representation allows multi-level geometric and volumetric analysis of A/V trees. Here, a new theory and method is presented to generate multi-level A/V tree representation of volumetric data and to compute quantitative measures of A/V tree geometry and topology at various tree hierarchies. The new method is primarily designed on arc skeleton computation followed by a tree construction based topologic and geometric analysis of the skeleton. The method starts with a volumetric A/V representation as input and generates its topologic and multi-level volumetric tree representations long with different multi-level morphometric measures. A new recursive merging and pruning algorithms are introduced to detect bad junctions and noisy branches often associated with digital geometric and topologic analysis. Also, a new notion of shortest axial path is introduced to improve the skeletal arc joining two junctions. The accuracy of the multi-level tree analysis algorithm has been evaluated using computer generated phantoms and pulmonary CT images of a pig vessel cast phantom while the reproducibility of method is evaluated using multi-user A/V separation of in vivo contrast-enhanced CT images of a pig lung at different respiratory volumes.

  13. Modulation of phosducin-like protein 3 (PhLP3 levels promotes cytoskeletal remodelling in a MAPK and RhoA-dependent manner.

    Directory of Open Access Journals (Sweden)

    Nandini V L Hayes

    Full Text Available Phosducin-like protein 3 (PhLP3 forms a ternary complex with the ATP-dependent molecular chaperone CCT and its folding client tubulin. In vitro studies suggest PhLP3 plays an inhibitory role in β-tubulin folding while conversely in vivo genetic studies suggest PhLP3 is required for the correct folding of β-tubulin. We have a particular interest in the cytoskeleton, its chaperones and their role in determining cellular phenotypes associated with high level recombinant protein expression from mammalian cell expression systems.As studies into PhLP3 function have been largely carried out in non mammalian systems, we examined the effect of human PhLP3 over-expression and siRNA silencing using a single murine siRNA on both tubulin and actin systems in mammalian Chinese hamster ovary (CHO cell lines. We show that over-expression of PhLP3 promotes an imbalance of α and β tubulin subunits, microtubule disassembly and cell death. In contrast, β-actin levels are not obviously perturbed. On-the-other-hand, RNA silencing of PhLP3 increases RhoA-dependent actin filament formation and focal adhesion formation and promotes a dramatic elongated fibroblast-like change in morphology. This was accompanied by an increase in phosphorylated MAPK which has been associated with promoting focal adhesion assembly and maturation. Transient overexpression of PhLP3 in knockdown experiments rescues cells from the morphological change observed during PhLP3 silencing but mitosis is perturbed, probably reflecting a tipping back of the balance of PhLP3 levels towards the overexpression state.Our results support the hypothesis that PhLP3 is important for the maintenance of β-tubulin levels in mammalian cells but also that its modulation can promote actin-based cytoskeletal remodelling by a mechanism linked with MAPK phosphorylation and RhoA-dependent changes. PhLP3 levels in mammalian cells are thus finely poised and represents a novel target for engineering industrially

  14. High Contrast Vacuum Nuller Testbed (VNT) Contrast, Performance and Null Control

    Science.gov (United States)

    Lyon, Richard G.; Clampin, Mark; Petrone, Peter; Mallik, Udayan; Madison, Timothy; Bolcar, Matthew R.

    2012-01-01

    Herein we report on our Visible Nulling Coronagraph high-contrast result of 109 contrast averaged over a focal planeregion extending from 14 D with the Vacuum Nuller Testbed (VNT) in a vibration isolated vacuum chamber. TheVNC is a hybrid interferometriccoronagraphic approach for exoplanet science. It operates with high Lyot stopefficiency for filled, segmented and sparse or diluted-aperture telescopes, thereby spanning the range of potential futureNASA flight telescopes. NASAGoddard Space Flight Center (GSFC) has a well-established effort to develop the VNCand its technologies, and has developed an incremental sequence of VNC testbeds to advance this approach and itsenabling technologies. These testbeds have enabled advancement of high-contrast, visible light, nulling interferometry tounprecedented levels. The VNC is based on a modified Mach-Zehnder nulling interferometer, with a W configurationto accommodate a hex-packed MEMS based deformable mirror, a coherent fiber bundle and achromatic phase shifters.We give an overview of the VNT and discuss the high-contrast laboratory results, the optical configuration, criticaltechnologies and null sensing and control.

  15. High contrast vacuum nuller testbed (VNT) contrast, performance, and null control

    Science.gov (United States)

    Lyon, Richard G.; Clampin, Mark; Petrone, Peter; Mallik, Udayan; Madison, Timothy; Bolcar, Matthew R.

    2012-09-01

    Herein we report on our Visible Nulling Coronagraph high-contrast result of 109 contrast averaged over a focal plane region extending from 1 - 4 λ/D with the Vacuum Nuller Testbed (VNT) in a vibration isolated vacuum chamber. The VNC is a hybrid interferometric/coronagraphic approach for exoplanet science. It operates with high Lyot stop efficiency for filled, segmented and sparse or diluted-aperture telescopes, thereby spanning the range of potential future NASA flight telescopes. NASA/Goddard Space Flight Center (GSFC) has a well-established effort to develop the VNC and its technologies, and has developed an incremental sequence of VNC testbeds to advance this approach and its enabling technologies. These testbeds have enabled advancement of high-contrast, visible light, nulling interferometry to unprecedented levels. The VNC is based on a modified Mach-Zehnder nulling interferometer, with a “W” configuration to accommodate a hex-packed MEMS based deformable mirror, a coherent fiber bundle and achromatic phase shifters. We give an overview of the VNT and discuss the high-contrast laboratory results, the optical configuration, critical technologies and null sensing and control.

  16. An Improved Image Contrast Assessment Method

    Directory of Open Access Journals (Sweden)

    Yuanyuan Fan

    2013-07-01

    Full Text Available Contrast is an important factor affecting the image quality. In order to overcome the problems of local band-limited contrast, a novel image contrast assessment method based on the property of HVS is proposed. Firstly, the image by low-pass filter is performed fast wavelet decomposition. Secondly, all levels of band-pass filtered image and its corresponding low-pass filtered image are obtained by processing wavelet coefficients. Thirdly, local band-limited contrast is calculated, and the local band-limited contrast entropy is calculated according to the definition of entropy, Finally, the contrast entropy of image is obtained by averaging the local band-limited contrast entropy weighed using CSF coefficient. The experiment results show that the best contrast image can be accurately identified in the sequence images obtained by adjusting the exposure time and stretching gray respectively, the assessment results accord with human visual characteristics and make up the lack of local band-limited contrast.

  17. Body Emotion Recognition Disproportionately Depends on Vertical Orientations during Childhood

    Science.gov (United States)

    Balas, Benjamin; Auen, Amanda; Saville, Alyson; Schmidt, Jamie

    2018-01-01

    Children's ability to recognize emotional expressions from faces and bodies develops during childhood. However, the low-level features that support accurate body emotion recognition during development have not been well characterized. This is in marked contrast to facial emotion recognition, which is known to depend upon specific spatial frequency…

  18. The Value of Contrast Echocardiography

    Directory of Open Access Journals (Sweden)

    Shannon C. Treiber

    2016-01-01

    Full Text Available Purpose: There is much evidence-based research proving the effectiveness of contrast echocardiography, but there are still questions and concerns about its specific uses. This study tested the effectiveness of contrast echocardiography in defining the left ventricular endocardial border. Methods: From 30 patients, a total of 60 echocardiograms –– 30 with and 30 without use of contrast –– were retrospectively reviewed by four blinded cardiologists with advanced training in echocardiography. No single cardiologist reviewed contrast and noncontrast images of the same patient. Each set of 30 echocardiograms was then studied for wall-motion scoring. Visualization of left ventricular wall segments and a global visualization confidence level of interpretation were recorded. Results: Of all wall segments (N = 510, 91% were visualized in echocardiograms with use of contrast, whereas 75% of the walls were visualized in echocardiograms without contrast (P < 0.001. Of 30 examinations, 17 contrast echocardiograms were read with high confidence compared to 6 without contrast use (P = 0.004. The number of walls visualized with contrast was increased in 18 patients (60%, whereas noncontrast echocardiograms yielded more visualized walls in 6 patients (20%, P = 0.002. Conclusions: This study demonstrates that contrast is valuable to echocardiographic imaging. Its use should be supported throughout echocardiography clinics and encouraged in certain patients for whom resting and stress echocardiography results without contrast often prove uninterpretable.

  19. Decreased serum level of NGF in alcohol-dependent patients with declined executive function

    Directory of Open Access Journals (Sweden)

    Bae H

    2014-11-01

    Full Text Available Hwallip Bae,1 Youngsun Ra,1 Changwoo Han,2 Dai-Jin Kim3 1Department of Psychiatry, Myongji Hospital, Goyang, 2Department of Psychiatry, Keyo Hospital, Uiwang, 3Department of Psychiatry, Seoul St Mary’s Hospital, College of Medicine, Catholic University of Korea, Seoul, South Korea Abstract: The role of neurotrophic factors has been highlighted as a cause of decline in the cognitive function of alcohol-dependent patients. It is known that nerve-growth factor (NGF, one of the neurotrophins, is related to the growth and differentiation of nerve cells, as well as to a decline in cognitive function. The purpose of this study was to investigate the relationship between decreased NGF levels and cognitive decline in alcohol-dependent patients. The serum concentration of NGF was measured in 38 patients with chronic alcohol dependence, and several neuropsychological tests were also performed for cognitive function assessment. The results indicated a significant correlation between serum NGF level and the trail-making test part B, which evaluates executive function, but did not show a significant correlation with other cognitive function tests. An increased serum level of NGF was associated with a decreased completion time in the trail-making test B, and this finding indicates that a high serum level of NGF is related to greater executive function. This finding may imply a protective role of NGF in preventing neuron damage among patients with alcohol dependence. Larger controlled studies will be necessary in the future to investigate this issue further. Keywords: nerve-growth factor, alcohol dependence, executive function, trail-making test

  20. Dependent vs. independent juvenile survival: contrasting drivers of variation and the buffering effect of parental care.

    Science.gov (United States)

    Dybala, Kristen E; Gardali, Thomas; Eadie, John M

    2013-07-01

    Juvenile survival is often found to be more sensitive than adult survival to variation in environmental conditions, and variation in juvenile survival can have significant impacts on population growth rates and viability. Therefore, understanding the population-level effects of environmental changes requires understanding the effects on juvenile survival. We hypothesized that parental care will buffer the survival of dependent juveniles from variation in environmental conditions, while the survival of independent juveniles will respond more strongly to environmental variation and, in turn, drive the overall variation in annual juvenile survival. We tested this parental-care hypothesis using a 30-year mark-recapture data set to model the survival of juvenile Song Sparrows (Melospiza melodia) during the dependent and independent stages. We examined the effects of weather, density, and cohort mean fledge date and body mass on annual variation in survival during the first 12 weeks after fledging, as well as effects of individual fledge date and body mass on individual variation in survival. The primary driver of annual variation in juvenile survival was precipitation during the previous rainy season, consistent with an effect on food availability, which had a strong positive effect on the survival of independent juveniles, but no effect on dependent juveniles. We also found strong support for effects of body mass and fledge date on individual survival probability, including striking differences in the effect of fledge date by stage. Our results provided evidence that different mechanisms influence juvenile survival during each stage of fledgling development, and that parental care buffers the survival of dependent juveniles from variation in environmental conditions. Consequently, variation in juvenile survival was driven by independent juveniles, not dependent juveniles, and studies focused only on survival during the dependent stage may not be able to detect the

  1. Synthetic generation of myocardial blood-oxygen-level-dependent MRI time series via structural sparse decomposition modeling.

    Science.gov (United States)

    Rusu, Cristian; Morisi, Rita; Boschetto, Davide; Dharmakumar, Rohan; Tsaftaris, Sotirios A

    2014-07-01

    This paper aims to identify approaches that generate appropriate synthetic data (computer generated) for cardiac phase-resolved blood-oxygen-level-dependent (CP-BOLD) MRI. CP-BOLD MRI is a new contrast agent- and stress-free approach for examining changes in myocardial oxygenation in response to coronary artery disease. However, since signal intensity changes are subtle, rapid visualization is not possible with the naked eye. Quantifying and visualizing the extent of disease relies on myocardial segmentation and registration to isolate the myocardium and establish temporal correspondences and ischemia detection algorithms to identify temporal differences in BOLD signal intensity patterns. If transmurality of the defect is of interest pixel-level analysis is necessary and thus a higher precision in registration is required. Such precision is currently not available affecting the design and performance of the ischemia detection algorithms. In this work, to enable algorithmic developments of ischemia detection irrespective to registration accuracy, we propose an approach that generates synthetic pixel-level myocardial time series. We do this by 1) modeling the temporal changes in BOLD signal intensity based on sparse multi-component dictionary learning, whereby segmentally derived myocardial time series are extracted from canine experimental data to learn the model; and 2) demonstrating the resemblance between real and synthetic time series for validation purposes. We envision that the proposed approach has the capacity to accelerate development of tools for ischemia detection while markedly reducing experimental costs so that cardiac BOLD MRI can be rapidly translated into the clinical arena for the noninvasive assessment of ischemic heart disease.

  2. Iodinated contrast media nephrotoxicity

    International Nuclear Information System (INIS)

    Meyrier, A.

    1994-01-01

    In the late seventies, iodinated contrast agents (ICA) were considered to be a major cause of acute iatrogenic renal failure. Over the last decade new contrast agents have been synthesized, nonionic and less hyperosmolar. The incidence of acute renal failure due to ICAs, varies from 3.7 to 70% of cases according to the series, with an average figure of 10.2%. The pathophysiology of ICA nephrotoxicity was mainly studied in laboratory animal models. Three main factors are involved in an inducing ICA-mediated decrease in glomerular filtration rate: reduction of the renal plasma flow, a direct cytotoxic effect on renal tubular cells and erythrocyte alteration leading to intra-renal sludge. Excluding dysglobulinemias with urinary excretion of immunoglobulin light chains, which represent a special case of maximum nephrotoxicity, 4 main risk factors of renal toxicity have been identified in nondiabetic subjects: previous renal failure with serum creatinine levels greater than 140 μmol per liter, extracellular dehydration, age over 60 and use of high doses of ICA and/or repeated ICA injections before serum creatinine levels return to baseline. Preventive measures for avoiding ICA nephrotoxicity are threefold: maintain or restore adequate hydration with saline infusion, stop NSAID treatment several days before ICA administration, and allow a 5 day interval before repeating contrast media injections. New, nonionic and moderately hyperosmolar contrast agents appear to be much less nephrotoxic than conventional ICAs in laboratory animals and in high-risk patients. It is advisable to select such contrast media for investigating high-risk patients. This approach was recently substantiated in well designed, randomized clinical studies which included more than 2 000 patients. (author)

  3. CVTresh: R Package for Level-Dependent Cross-Validation Thresholding

    Directory of Open Access Journals (Sweden)

    Donghoh Kim

    2006-04-01

    Full Text Available The core of the wavelet approach to nonparametric regression is thresholding of wavelet coefficients. This paper reviews a cross-validation method for the selection of the thresholding value in wavelet shrinkage of Oh, Kim, and Lee (2006, and introduces the R package CVThresh implementing details of the calculations for the procedures. This procedure is implemented by coupling a conventional cross-validation with a fast imputation method, so that it overcomes a limitation of data length, a power of 2. It can be easily applied to the classical leave-one-out cross-validation and K-fold cross-validation. Since the procedure is computationally fast, a level-dependent cross-validation can be developed for wavelet shrinkage of data with various sparseness according to levels.

  4. CVTresh: R Package for Level-Dependent Cross-Validation Thresholding

    Directory of Open Access Journals (Sweden)

    Donghoh Kim

    2006-04-01

    Full Text Available The core of the wavelet approach to nonparametric regression is thresholding of wavelet coefficients. This paper reviews a cross-validation method for the selection of the thresholding value in wavelet shrinkage of Oh, Kim, and Lee (2006, and introduces the R package CVThresh implementing details of the calculations for the procedures.This procedure is implemented by coupling a conventional cross-validation with a fast imputation method, so that it overcomes a limitation of data length, a power of 2. It can be easily applied to the classical leave-one-out cross-validation and K-fold cross-validation. Since the procedure is computationally fast, a level-dependent cross-validation can be developed for wavelet shrinkage of data with various sparseness according to levels.

  5. Thermal- and pH-Dependent Size Variable Radical Nanoparticles and Its Water Proton Relaxivity for Metal-Free MRI Functional Contrast Agents.

    Science.gov (United States)

    Morishita, Kosuke; Murayama, Shuhei; Araki, Takeru; Aoki, Ichio; Karasawa, Satoru

    2016-09-16

    For development of the metal-free MRI contrast agents, we prepared the supra-molecular organic radical, TEMPO-UBD, carrying TEMPO radical, as well as the urea, alkyl group, and phenyl ring, which demonstrate self-assembly behaviors using noncovalent bonds in an aqueous solution. In addition, TEMPO-UBD has the tertiary amine and the oligoethylene glycol chains (OEGs) for the function of pH and thermal responsiveness. By dynamic light scattering and transmission electron microscopy imaging, the resulting self-assembly was seen to form the spherical nanoparticles 10-150 nm in size. On heating, interestingly, the nanoparticles showed a lower critical solution temperature (LCST) behavior having two-step variation. This double-LCST behavior is the first such example among the supra-molecules. To evaluate of the ability as MRI contrast agents, the values of proton ((1)H) longitudinal relaxivity (r1) were determined using MRI apparatus. In conditions below and above CAC at pH 7.0, the distinguishable r1 values were estimated to be 0.17 and 0.21 mM(-1) s(1), indicating the suppression of fast tumbling motion of TEMPO moiety in a nanoparticle. Furthermore, r1 values became larger in the order of pH 7.0 > 9.0 > 5.0. Those thermal and pH dependencies indicated the possibility of metal-fee MRI functional contrast agents in the future.

  6. Contrast characteristics of barium preparations and the timing of exposure

    OpenAIRE

    渋谷, 光一; 中桐, 義忠; 東, 義晴; 杉田, 勝彦; 小橋, 高郎; 大倉, 保彦; 丹谷, 延義; 三上, 泰隆; 平木, 祥夫

    1995-01-01

    We studied the relationship between the contrast characteristics of barium suspension and timing of exposure. We poured several kinds of barium preparations on the phantom manufactured by ourselves, and took X-ray pictures continuously by a DSA system. We analyzed each of the characteris-tics of the contrast. The time which was reguired for the contrast to reach the peak (Contrast Peak Time ; CPT) was unrelated with the kind of barium preparations used. It depended on the viscosity of the con...

  7. The application of phase contrast X-ray techniques for imaging Li-ion battery electrodes

    Science.gov (United States)

    Eastwood, D. S.; Bradley, R. S.; Tariq, F.; Cooper, S. J.; Taiwo, O. O.; Gelb, J.; Merkle, A.; Brett, D. J. L.; Brandon, N. P.; Withers, P. J.; Lee, P. D.; Shearing, P. R.

    2014-04-01

    In order to accelerate the commercialization of fuel cells and batteries across a range of applications, an understanding of the mechanisms by which they age and degrade at the microstructural level is required. Here, the most widely commercialized Li-ion batteries based on porous graphite based electrodes which de/intercalate Li+ ions during charge/discharge are studied by two phase contrast enhanced X-ray imaging modes, namely in-line phase contrast and Zernike phase contrast at the micro (synchrotron) and nano (laboratory X-ray microscope) level, respectively. The rate of charge cycling is directly dependent on the nature of the electrode microstructure, which are typically complex multi-scale 3D geometries with significant microstructural heterogeneities. We have been able to characterise the porosity and the tortuosity by micro-CT as well as the morphology of 5 individual graphite particles by nano-tomography finding that while their volume varied significantly their sphericity was surprisingly similar. The volume specific surface areas of the individual grains measured by nano-CT are significantly larger than the total volume specific surface area of the electrode from the micro-CT imaging, which can be attributed to the greater particle surface area visible at higher resolution.

  8. The application of phase contrast X-ray techniques for imaging Li-ion battery electrodes

    International Nuclear Information System (INIS)

    Eastwood, D.S.; Bradley, R.S.; Tariq, F.; Cooper, S.J.; Taiwo, O.O.; Gelb, J.; Merkle, A.; Brett, D.J.L.; Brandon, N.P.; Withers, P.J.; Lee, P.D.; Shearing, P.R.

    2014-01-01

    In order to accelerate the commercialization of fuel cells and batteries across a range of applications, an understanding of the mechanisms by which they age and degrade at the microstructural level is required. Here, the most widely commercialized Li-ion batteries based on porous graphite based electrodes which de/intercalate Li + ions during charge/discharge are studied by two phase contrast enhanced X-ray imaging modes, namely in-line phase contrast and Zernike phase contrast at the micro (synchrotron) and nano (laboratory X-ray microscope) level, respectively. The rate of charge cycling is directly dependent on the nature of the electrode microstructure, which are typically complex multi-scale 3D geometries with significant microstructural heterogeneities. We have been able to characterise the porosity and the tortuosity by micro-CT as well as the morphology of 5 individual graphite particles by nano-tomography finding that while their volume varied significantly their sphericity was surprisingly similar. The volume specific surface areas of the individual grains measured by nano-CT are significantly larger than the total volume specific surface area of the electrode from the micro-CT imaging, which can be attributed to the greater particle surface area visible at higher resolution

  9. Comparison of neutral oral contrast versus positive oral contrast medium in abdominal multidetector CT

    International Nuclear Information System (INIS)

    Berther, Ralph; Eckhardt, Boris; Zollikofer, Christoph L.; Patak, Michael A.; Erturk, Sukru M.

    2008-01-01

    To determine whether neutral contrast agents with water-equivalent intraluminal attenuation can improve delineation of the bowel wall and increase overall image quality for a non-selected patient population, a neutral oral contrast agent (3% mannitol) was administered to 100 patients referred for abdominal multidetector row computed tomography (MDCT). Their results were compared with those of 100 patients given a positive oral contrast agent. Qualitative and quantitative measurements were done on different levels of the gastrointestinal tract by three experienced readers. Patients given the neutral oral contrast agent showed significant better qualitative results for bowel distension (P<0.001), homogeneity of the luminal content (P<0.001), delineation of the bowel-wall to the lumen (P<0.001) and to the mesentery (P<0.001) and artifacts (P<0.001), leading to a significant better overall image quality (P<0.001) than patients receiving positive oral contrast medium. The quantitative measurements revealed significant better distension (P<0.001) and wall to lumen delineation (P<0.001) for the patients receiving neutral oral contrast medium. The present results show that the neutral oral contrast agent (mannitol) produced better distension, better homogeneity and better delineation of the bowel wall leading to a higher overall image quality than the positive oral contrast medium in a non-selected patient population. (orig.)

  10. Fermi level dependent native defect formation: Consequences for metal-semiconductor and semiconductor-semiconductor interfaces

    International Nuclear Information System (INIS)

    Walukiewicz, W.

    1988-02-01

    The amphoteric native defect model of the Schottky barrier formation is used to analyze the Fermi level pinning at metal/semiconductor interfaces for submonolayer metal coverages. It is assumed that the energy required for defect generation is released in the process of surface back-relaxation. Model calculations for metal/GaAs interfaces show a weak dependence of the Fermi level pinning on the thickness of metal deposited at room temperature. This weak dependence indicates a strong dependence of the defect formation energy on the Fermi level, a unique feature of amphoteric native defects. This result is in very good agreement with experimental data. It is shown that a very distinct asymmetry in the Fermi level pinning on p- and n-type GaAs observed at liquid nitrogen temperatures can be understood in terms of much different recombination rates for amphoteric native defects in those two types of materials. Also, it is demonstrated that the Fermi level stabilization energy, a central concept of the amphoteric defect system, plays a fundamental role in other phenomena in semiconductors such as semiconductor/semiconductor heterointerface intermixing and saturation of free carrier concentration. 33 refs., 6 figs

  11. Contrast enhanced CT of spinal cord angioma

    International Nuclear Information System (INIS)

    Nakamura, Takahiko; Ebitani, Tsutomu; Honma, Takao; Sofue, Muroto; Nakamura, Shigeru

    1982-01-01

    Contrast enhanced CT on 6 patients with spinal cord angioma showed enhancement in 2 of them. The conditions to produce contrast enhancement were the window width of 100 - 200, and the window level of 0 - 50. In spinal cord angioma, contrast enhanced CT is presently only an adjunct to angiography and myelography. Nevertheless, contrast enhanced CT is useful in the screening test for spinal cord angioma, in the patients who are nonindicated to angiography, and in the postoperative follow-up. (Ueda, J.)

  12. Multi-level restricted maximum likelihood covariance estimation and kriging for large non-gridded spatial datasets

    KAUST Repository

    Castrillon, Julio

    2015-11-10

    We develop a multi-level restricted Gaussian maximum likelihood method for estimating the covariance function parameters and computing the best unbiased predictor. Our approach produces a new set of multi-level contrasts where the deterministic parameters of the model are filtered out thus enabling the estimation of the covariance parameters to be decoupled from the deterministic component. Moreover, the multi-level covariance matrix of the contrasts exhibit fast decay that is dependent on the smoothness of the covariance function. Due to the fast decay of the multi-level covariance matrix coefficients only a small set is computed with a level dependent criterion. We demonstrate our approach on problems of up to 512,000 observations with a Matérn covariance function and highly irregular placements of the observations. In addition, these problems are numerically unstable and hard to solve with traditional methods.

  13. Levels of physical dependence on tobacco among adolescent smokers in Cyprus.

    Science.gov (United States)

    Christophi, Costas A; Pampaka, Despina; Paisi, Martha; Ioannou, Solonas; DiFranza, Joseph R

    2016-09-01

    The purpose of this study is to assess tobacco dependence among Cypriot adolescents and examine its association to cigarette consumption and attitudes towards smoking. The current study used cross-sectional data from the 2011 Cyprus Global Youth Tobacco Survey which adopted multistage cluster sampling methods to select adolescents registered in middle and high schools in Cyprus. Tobacco use, physical dependence on tobacco, and attitudes towards tobacco use were measured in 187 adolescents aged 13-18years old who reported that they had smoked at least once in the preceding 30days. Physical dependence was assessed using the Levels of Physical Dependence scale. Physical dependence was present in 86% of the adolescent smokers. The mean latency to needing among smokers in the highest dependence group was 101h. Significant associations were observed between physical dependence and the perceived difficulty in quitting (OR=13.1, 95% CI: 4.0, 43.0) as well as the expectation to continue smoking for the next five years (OR=3.3, 95% CI: 1.3, 8.4). Significant associations were also observed between physical dependence and the number of smoking days per month, daily smoking, daily cigarette consumption, lifetime cigarette consumption, and perceived difficulty in abstaining from smoking for one week. Physical dependence provides a symptom-based approach to assess dependence and it is a strong predictor of adolescents' perceptions of their ability to quit or to refrain from smoking for a week. Physical dependence on tobacco was highly prevalent among adolescent smokers in Cyprus and it was associated with greater perceived difficulty in quitting. Interventions targeting adolescent smoking must account for the high prevalence of physical dependence. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  14. Effect of dietary restriction on metabolic, anatomic and molecular traits in mice depends on the initial level of basal metabolic rate.

    Science.gov (United States)

    Brzek, Pawel; Ksiazek, Aneta; Dobrzyn, Agnieszka; Konarzewski, Marek

    2012-09-15

    Dietary restriction (DR)-related delay of ageing is hypothesized to be mediated by the reduction of the metabolic rate (MR). However, studies on the effect of DR on MR have produced equivocal results. We demonstrated that this lack of congruency can be due to a variation in the initial level of MR within a given pool of experimental subjects. We subjected laboratory mice from two line types divergently selected for basal MR (BMR) to 30% DR lasting 6 months to test whether the effect of DR depends on the initial variation in BMR and peak MR. BMR and peak MR were independently affected by DR. The effect of DR was stronger in line types with higher initial levels of MR. Line-type-specific changes in the proportions of body components explained contrasting effects of DR on the mass-corrected BMR, which decreased in the high-BMR line type and did not change in the low-BMR line type. We conclude that the initial variation in MR can significantly affect response to DR. However, we found no association between the level of MR and mechanisms underlying the susceptibility to or protection against oxidative stress.

  15. Basic characteristics of simultaneous color contrast revisited.

    Science.gov (United States)

    Ekroll, Vebjørn; Faul, Franz

    2012-10-01

    In this article, we present evidence supporting the hypothesis that the local mechanism of simultaneous color contrast is the same as the mechanism responsible for the crispening effect and the gamut expansion effect. A theoretically important corollary of this hypothesis is that the basic characteristics of simultaneous contrast are at odds with traditional laws. First, this hypothesis implies that the direction of the simultaneous contrast effect in color space is given by the vector from surround to target and not--as traditionally assumed--by the hue complementary to that of the surround. Second, it implies that the size of the simultaneous contrast effect depends on the difference between the target and surround colors in a way that challenges Kirschmann's fourth law. The widespread belief in the traditional laws, we argue, is due to the confounding influence of temporal adaptation.

  16. Instrumentation for contrast echocardiography: technology and techniques.

    Science.gov (United States)

    Kaul, Sanjiv

    2002-11-18

    Contrast echocardiography is the only clinical imaging technique in which the imaging modality (ultrasound) can cause a change in the contrast agent (microbubbles). The change in the contrast agent can range from small oscillations of the microbubbles at a low mechanical index to their disruption at a high mechanical index. The specific mechanical index required to produce these various effects may be different for each contrast agent, depending on the bubble dimension as well as shell and gas characteristics. These alterations in bubbles result in changes in ultrasound backscatter that are specific for the bubbles themselves, rather than for tissue, and are therefore exploited for imaging their presence in tissue. These signal-processing techniques have resulted in an increased signal-to-noise ratio from bubbles vis-à-vis the tissue and have made online assessment of myocardial perfusion possible.

  17. Local order dependent impurity levels in alloy semiconductors

    International Nuclear Information System (INIS)

    Silva, C.E.T.G. da; Ecole Normale Superieure, 75 - Paris

    1981-01-01

    We develop a one band/may sites model for an isoelectronic impurity in a semiconductor alloy. The cluster-Bethe-lattice approximation is used to study the dependence of the impurity energy level upon the short range order (SRO) of the alloy. The Kikuchi parametrization is used to describe the latter. We take into account diagonal disorder only, with possible off-diagonal relaxation around the impurity site. All the inequivalent clusters of the impurity site and its first nearest neighbours are considered, thus including the important short range alloy potential fluctuations. Results are presented for the local density of impurity states, for different degrees of SRO in the alloy. (Author) [pt

  18. Na+/Ca2+ exchange inhibitor, KB-R7943, attenuates contrast-induced acute 
kidney injury.

    Science.gov (United States)

    Yang, Dingwei; Yang, Dingping; Jia, Ruhan; Tan, Jin

    2013-01-01

    Intracellular Ca2+ overload is considered to be a key factor in contrast-induced acute kidney injury (CI-AKI). The Na+/Ca2+ exchanger (NCX) system is one of the main pathways of intracellular Ca2+ overload. We investigated the effects of KB-R7943, an inhibitor of the reverse mode of NCX, on CI-AKI in a rat model. Rats were divided into control group, CI-AKI group and pretreatment groups (with KB-R7943 dose of 5 or 10 mg/kg). CI-AKI was induced by diatrizoate administration in rats with cholesterol-supplemented diet for 8 weeks. Renal function and renal hemodynamics were determined 1 day following contrast medium administration. Renal histopathology was observed by light microscope. Renal tubular apoptosis was examined by TUNEL. Renal endothelin-1 (ET-1) was measured by radioimmunoassay. Renal malondialdehyde (MDA) and catalase (CAT) were measured as oxidative markers. Levels of serum creatinine (Scr), renal ET-1, MDA and CAT, and resistance index (RI) of renal blood vessels increased significantly in CI-AKI rats. The 
increases in Scr and RI of renal blood vessels induced by diatrizoate were suppressed significantly and 
dose-dependently by pretreatment with KB-R7943. Histopathological and TUNEL results showed that 
the contrast medium-induced severe renal tubular 
necrosis and apoptosis were significantly and dose-dependently attenuated by KB-R7943. KB-R7943 significantly suppressed the increment of renal ET-1 content and MDA and CAT level induced by contrast medium administration. Activation of the reverse mode of NCX, followed by ET-1 overproduction and increased oxidative stress, seems to play an important role in the pathogenesis of CI-AKI. The inhibitor of the reverse mode of NCX, KB-R7943, has renoprotective effects on CI-AKI.

  19. Chromatic blur perception in the presence of luminance contrast.

    Science.gov (United States)

    Jennings, Ben J; Kingdom, Frederick A A

    2017-06-01

    Hel-Or showed that blurring the chromatic but not the luminance layer of an image of a natural scene failed to elicit any impression of blur. Subsequent studies have suggested that this effect is due either to chromatic blur being masked by spatially contiguous luminance edges in the scene (Journal of Vision 13 (2013) 14), or to a relatively compressed transducer function for chromatic blur (Journal of Vision 15 (2015) 6). To test between the two explanations we conducted experiments using as stimuli both images of natural scenes as well as simple edges. First, we found that in color-and-luminance images of natural scenes more chromatic blur was needed to perceptually match a given level of blur in an isoluminant, i.e. colour-only scene. However, when the luminance layer in the scene was rotated relative to the chromatic layer, thus removing the colour-luminance edge correlations, the matched blur levels were near equal. Both results are consistent with Sharman et al.'s explanation. Second, when observers matched the blurs of luminance-only with isoluminant scenes, the matched blurs were equal, against Kingdom et al.'s prediction. Third, we measured the perceived blur in a square-wave as a function of (i) contrast (ii) number of luminance edges and (iii) the relative spatial phase between the colour and luminance edges. We found that the perceived chromatic blur was dependent on both relative phase and the number of luminance edges, or dependent on the luminance contrast if only a single edge is present. We conclude that this Hel-Or effect is largely due to masking of chromatic blur by spatially contiguous luminance edges. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Level of khat dependence, use patterns, and psychosocial correlates in Yemen: a cross-sectional investigation.

    Science.gov (United States)

    Nakajima, Motohiro; Hoffman, Richard; al'Absi, Mustafa

    2017-05-01

    Chronic khat use is associated with negative health consequences. However, no study has fully characterized individuals who are khat dependent. This paper examines socio-demographic and psychosocial correlates of adult khat dependence. A total of 270 khat users (129 women) in Yemen completed face-to-face interviews and provided demographic information and data on patterns of khat use, subjective mood, and sleep quality. The Severity of Dependence Scale-Khat (SDS-khat) was used to assess level of khat dependence. A series of analysis of variance was conducted. Khat users, on average, used khat for 5.2 hours a day (SD = 2.3) for 5.7 days a week (SD = 2.0). Individuals who screened positive for khat dependence reported longer duration of khat sessions per day, higher frequency of khat use per week, greater levels of negative mood and sleep disturbances, and were more likely to endorse physical symptoms after khat use (P < 0.05). Future research should elucidate mechanisms responsible for khat dependence symptomatology.

  1. Elevated serum BAFF levels in patients with localized scleroderma in contrast to other organ-specific autoimmune diseases.

    Science.gov (United States)

    Matsushita, Takashi; Hasegawa, Minoru; Matsushita, Yukiyo; Echigo, Takeshi; Wayaku, Takamasa; Horikawa, Mayuka; Ogawa, Fumihide; Takehara, Kazuhiko; Sato, Shinichi

    2007-02-01

    Serum levels of B-cell activating factor belonging to the tumor necrosis factor family (BAFF), a potent B-cell survival factor, are elevated in patients with systemic autoimmune diseases, such as systemic lupus erythematosus (SLE), rheumatoid arthritis and systemic sclerosis (SSc). The objective of this study was to determine serum BAFF levels and relate the results to the clinical features in patients with organ-specific autoimmune diseases of the skin, such as localized scleroderma and autoimmune bullous diseases. Serum BAFF levels were examined by enzyme-linked immunosorbent assay in 44 patients with localized scleroderma, 20 with pemphigus vulgaris/pemphigus foliaceus, 20 with bullous pemphigoid and 30 healthy controls. Twenty patients with SSc and 20 with SLE were also examined as disease controls. Serum BAFF levels were elevated in localized scleroderma patients compared with healthy controls. Concerning localized scleroderma subgroups, patients with generalized morphea, the severest form of localized scleroderma, had higher serum BAFF levels than linear scleroderma or morphea patients. The BAFF levels of generalized morphea were comparable with those of SSc or SLE. Furthermore, serum BAFF levels correlated positively with antihistone antibody levels and the severity of skin lesion as well as the number of skin lesions. By contrast, serum BAFF levels were not significantly elevated in patients with pemphigus or pemphigoid. These results suggest that BAFF may be contributing to autoimmunity and disease development in localized scleroderma.

  2. Defects level evaluation of LiTiZn ferrite ceramics using temperature dependence of initial permeability

    Science.gov (United States)

    Malyshev, A. V.; Petrova, A. B.; Sokolovskiy, A. N.; Surzhikov, A. P.

    2018-06-01

    The method for evaluating the integral defects level and chemical homogeneity of ferrite ceramics based on temperature dependence analysis of initial permeability is suggested. A phenomenological expression for the description of such dependence was suggested and an interpretation of its main parameters was given. It was shown, that the main criterion of the integral defects level of ferrite ceramics is relation of two parameters correlating with elastic stress value in a material. An indicator of structural perfection can be a maximum value of initial permeability close to Curie point as well. The temperature dependences of initial permeability have analyzed for samples sintered in laboratory conditions and for the ferrite industrial product. The proposed method allows controlling integral defects level of the soft ferrite products and has high sensitivity compare to typical X-ray methods.

  3. Liberation of plasma histamine after application of non-ionic contrast media

    International Nuclear Information System (INIS)

    Weiss, H.D.; Jansen, O.; Schallock, J.

    1989-01-01

    In 94 patients the levels of plasmahistamine have been measured after application of three non-ionic contrast media (Iopromid, Iopamidol, Iohexol) and after application of blood-isotonic saline solution. A significant liberation of histamine could be observed after administration of contrast media and also after administration of saline solution. Neither between the three nonionic contrast media nor between the contrast media and the saline solution significant differences could be measured. Administering contrast media after subsequently saline solution the levels of histamine were lower than in case of pure contrast media application. A psychogen induced histamine liberation is discussed. (orig.) [de

  4. STM contrast inversion of the Fe(1 1 0) surface

    Energy Technology Data Exchange (ETDEWEB)

    Mándi, Gábor [Budapest University of Technology and Economics, Department of Theoretical Physics, Budafoki út 8, H-1111 Budapest (Hungary); Palotás, Krisztián, E-mail: palotas@phy.bme.hu [Budapest University of Technology and Economics, Department of Theoretical Physics, Budafoki út 8, H-1111 Budapest (Hungary); Condensed Matter Research Group of the Hungarian Academy of Sciences, Budafoki út 8, H-1111 Budapest (Hungary)

    2014-06-01

    We extend the orbital-dependent electron tunneling model implemented within the three-dimensional (3D) Wentzel–Kramers–Brillouin (WKB) atom-superposition approach to simulate spin-polarized scanning tunneling microscopy (SP-STM) above magnetic surfaces. The tunneling model is based on the electronic structure data of the magnetic tip and surface obtained from first principles. Applying our method, we analyze the orbital contributions to the tunneling current, and study the nature of atomic contrast reversals occurring on constant-current SP-STM images above the Fe(1 1 0) surface. We find an interplay of orbital-dependent tunneling and spin-polarization effects responsible for the contrast inversion, and we discuss its dependence on the bias voltage, on the tip-sample distance, and on the tip orbital composition.

  5. Renal streaky artifact during contrast-enhanced abdominal and pelvic CT: Comparison of high versus low osmolality contrast media

    International Nuclear Information System (INIS)

    Kim, Dae Hong; Kim, Jong Chul; Lee, Chung Keun; Shin, Kyoung Suk

    1994-01-01

    Introduction of low osmolality contrast agent(LOCA) has allowed safer, more comfortable contrast-enhanced CT examination, but there has been significant increase in image degradation when evaluating the kidneys due to streaky artifact. The authors reviewed findings of contrast- enhanced abdominal and pelvic computed tomography(CT) to know the difference of renal streaky artifact between a high osmolality contrast agent (HOCA) and LOCA. This study included two hundred contrast-enhanced CT in 200 patients, 100 performed with HOCA(meglumine ioglicate, 150 ml) and 100 performed with LOCA (iopromide,150 ml). The severity of renal streaky artifact was compared between HOCA and LOCA groups. Of the scans performed with HOCA, 40 had no artifact, 52 had grade I artifact, 6 had grade II artifact, and 2 had grade III artifact. Of the scans preformed with LOCA, 23 had no artifact, 44 had grade I artifact, 29 had grade II artifact, and 4 had grade III artifact. There was significant difference in the degree of the streaky artifact depending upon the osmolality of the contrast media used(by χ 2 -test, P=.0001). The results of this study revealed a statistically significant increased incidence of artifacts and distortions of renal image with LOCA when compared with HOCA

  6. Age and dosage-level dependence of radium retention in beagles

    International Nuclear Information System (INIS)

    Parks, N.J.; Pool, R.R.; Williams, J.R.; Wolf, H.G.

    1978-01-01

    Radium retention was measured over the lifespan of 46 beagles exposed by eight semimonthly injections at 60 to 160, 120 to 220, or 435 to 535 days of age. Injection dosage levels ranged from 0.37 to 10 μCi of 226 Ra/kg. The fractional retention of each animal is described in terms of a modified power function, R = [(t + d)/d] - /sup b/. Young adult beagles (approximately equal to 10 kg) injected at a mean age (A) of 485 days with 226 Ra at dosage levels of 10, 3.3, 1.11, and 0.37 μCi/kg had mean values for d and b of [0.897; 0.187], [2.015; 0.206], [2.778; 0.257], and [3.894; 0.274], respectively. Juvenile beagles injected with 10 μCi/kg at A = 110 days (average weight approximately equal to 6 kg) and at A = 170 days (average weight approximately equal to 10 kg) had mean values for d and b of [137; 0.277] and [5.53; 0.086], respectively. The d values are geometric means and the units are days; b values are arithmetic means. The formula for deriving the age-dependent retention function for dogs is given. The beagle results were correlated with human data in terms of age-to-equivalent fraction of adult body calcium content and were used to construct a similar age-dependent retention function for chronically exposed people. The correlation of age-dependent retention functions for beagles and humans is used to estimate scaling factors between the two species for the fraction of injected dosage associated with bone for various ages of exposure

  7. Discrimination of Arabic Contrasts by American Learners

    Science.gov (United States)

    Al Mahmoud, Mahmoud S.

    2013-01-01

    This article reports on second language perception of non-native contrasts. The study specifically tests the perceptual assimilation model (PAM) by examining American learners' ability to discriminate Arabic contrasts. Twenty two native American speakers enrolled in a university level Arabic language program took part in a forced choice AXB…

  8. The application of phase contrast X-ray techniques for imaging Li-ion battery electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Eastwood, D.S. [Manchester X-ray Imaging Facility, School of Materials, University of Manchester, Manchester M13 9PL (United Kingdom); Research Complex at Harwell, Didcot, Oxon OX11 0FA (United Kingdom); Bradley, R.S. [Manchester X-ray Imaging Facility, School of Materials, University of Manchester, Manchester M13 9PL (United Kingdom); Tariq, F.; Cooper, S.J. [Dept. Earth Science and Engineering, Imperial College London, London SW7 2AZ (United Kingdom); Taiwo, O.O. [Dept. Chemical Engineering, University College London, London WC1E 7JE (United Kingdom); Gelb, J.; Merkle, A. [Carl Zeiss X-ray Microscopy Inc., Pleasanton, CA 94588 (United States); Brett, D.J.L. [Dept. Chemical Engineering, University College London, London WC1E 7JE (United Kingdom); Brandon, N.P. [Dept. Earth Science and Engineering, Imperial College London, London SW7 2AZ (United Kingdom); Withers, P.J.; Lee, P.D. [Manchester X-ray Imaging Facility, School of Materials, University of Manchester, Manchester M13 9PL (United Kingdom); Research Complex at Harwell, Didcot, Oxon OX11 0FA (United Kingdom); Shearing, P.R., E-mail: p.shearing@ucl.ac.uk [Dept. Chemical Engineering, University College London, London WC1E 7JE (United Kingdom)

    2014-04-01

    In order to accelerate the commercialization of fuel cells and batteries across a range of applications, an understanding of the mechanisms by which they age and degrade at the microstructural level is required. Here, the most widely commercialized Li-ion batteries based on porous graphite based electrodes which de/intercalate Li{sup +} ions during charge/discharge are studied by two phase contrast enhanced X-ray imaging modes, namely in-line phase contrast and Zernike phase contrast at the micro (synchrotron) and nano (laboratory X-ray microscope) level, respectively. The rate of charge cycling is directly dependent on the nature of the electrode microstructure, which are typically complex multi-scale 3D geometries with significant microstructural heterogeneities. We have been able to characterise the porosity and the tortuosity by micro-CT as well as the morphology of 5 individual graphite particles by nano-tomography finding that while their volume varied significantly their sphericity was surprisingly similar. The volume specific surface areas of the individual grains measured by nano-CT are significantly larger than the total volume specific surface area of the electrode from the micro-CT imaging, which can be attributed to the greater particle surface area visible at higher resolution.

  9. Order Level Inventory Models for Deteriorating Seasonable/Fashionable Products with Time Dependent Demand and Shortages

    OpenAIRE

    Skouri, K.; Konstantaras, I.

    2009-01-01

    An order level inventory model for seasonable/fashionable products subject to a period of increasing demand followed by a period of level demand and then by a period of decreasing demand rate (three branches ramp type demand rate) is considered. The unsatisfied demand is partially backlogged with a time dependent backlogging rate. In addition, the product deteriorates with a time dependent, namely, Weibull, deterioration rate. The model is studied under the following different replenishment p...

  10. Contrast enhancement technique in brain 3D-CTA studies. Optimizing the amount of contrast medium according to scan time based on TDC

    International Nuclear Information System (INIS)

    Terasawa, Kazuaki; Hatcho, Atsushi

    2008-01-01

    In three-dimensional CT angiography (3D-CTA), good reproducibility can be obtained by maintaining the maximum CT numbers (HU) at a specified level. However, the correlation between the scan time and the injection time showed that the maximum CT numbers increased and varied due to the additional contrast enhancement effect from recirculation of the injected contrast medium for longer injection times when the dose of iodinated contrast medium per unit time (mgI/s) was maintained at a specified level based on the time-density curve (TDC) of the phantom. The amount of contrast medium employed at our hospital has been optimized based on an iodinated contrast medium dose per unit time providing a contrast enhancement effect of 300 HU in the middle cerebral artery. Using this standard, a TDC phantom was employed to obtain an iodinated contrast medium dose per unit time, permitting equivalent maximum CT values (used as standard values) to be obtained by changing the injection time. A contrast-enhancement technique that accounts for the variation in the scan time was evaluated. Strong correlations were observed between the scan time and the injection time (R 2 =0.969) and between the injection time and the dose of iodinated contrast medium per unit body weight (R 2 =0.994). We conclude that adjusting the dose of iodinated contrast medium per unit body weight per unit time according to the scan time permits optimization of the contrast-enhancement technique. (author)

  11. Spin-dependent level density in interacting Boson-Fermion-Fermion model of the Odd-Odd Nucleus 196Au

    International Nuclear Information System (INIS)

    Kabashi, S.; Bekteshi, S.; Ahmetaj, S.; Shaqiri, Z.

    2009-01-01

    The level density of the odd-odd nucleus 196 Au is investigated in the interacting boson-fermion-fermion model (IBFFM) which accounts for collectivity and complex interaction between quasiparticle and collective modes.The IBFFM spin-dependent level densities show high-spin reduction with respect to Bethe formula.This can be well accounted for by a modified spin-dependent level density formula. (authors)

  12. Gender Differences in the Effect of Tobacco Use on Brain Phosphocreatine Levels in Methamphetamine Dependent Subjects

    Science.gov (United States)

    Sung, Young-Hoon; Yurgelun-Todd, Deborah A.; Kondo, Douglas G.; Shi, Xian-Feng; Lundberg, Kelly J.; Hellem, Tracy L.; Huber, Rebekah S.; McGlade, Erin C.; Jeong, Eun-Kee; Renshaw, Perry F.

    2015-01-01

    Background A high prevalence of tobacco smoking has been observed in methamphetamine users, but there have been no in vivo brain neurochemistry studies addressing gender effects of tobacco smoking in methamphetamine users. Methamphetamine addiction is associated with increased risk of depression and anxiety in females. There is increasing evidence that selective analogues of nicotine, a principal active component of tobacco smoking, may improve depression and cognitive performance in animals and humans. Objectives To investigate the effects of tobacco smoking and gender on brain phosphocreatine (PCr) levels, a marker of brain energy metabolism reported to be reduced in methamphetamine-dependent subjects. Methods Thirty female and twenty-seven male methamphetamine-dependent subjects were evaluated with phosphorus-31 magnetic resonance spectroscopy (31P-MRS) to measure PCr levels within the pregenual anterior cingulate, which has been implicated in methamphetamine neurotoxicity. Results Analysis of covariance revealed that there were statistically significant slope (PCr versus lifetime amount of tobacco smoking) differences between female and male methamphetamine-dependent subjects (p=0.03). In females, there was also a statistically significant interaction between lifetime amounts of tobacco smoking and methamphetamine in regard to PCr levels (p=0.01), which suggests that tobacco smoking may have a more significant positive impact on brain PCr levels in heavy, as opposed to light to moderate, methamphetamine-dependent females. Conclusion These results indicate that tobacco smoking has gender-specific effects in terms of increased anterior cingulate high energy PCr levels in methamphetamine-dependent subjects. Cigarette smoking in methamphetamine-dependent women, particularly those with heavy methamphetamine use, may have a potentially protective effect upon neuronal metabolism. PMID:25871447

  13. The influence of body temperature on image contrast in post mortem MRI

    International Nuclear Information System (INIS)

    Ruder, Thomas D.; Hatch, Gary M.; Siegenthaler, Lea; Ampanozi, Garyfalia; Mathier, Sandra; Thali, Michael J.; Weber, Oliver M.

    2012-01-01

    Objective: To assess the temperature dependency of tissue contrast on post mortem magnetic resonance (PMMR) images both objectively and subjectively; and to visually demonstrate the changes of image contrast at various temperatures. Materials and methods: The study was approved by the responsible justice department and the ethics committee. The contrast of water, fat, and muscle was measured using regions of interest (ROI) in the orbit of 41 human corpses to assess how body temperature (range 2.1–39.8 °C) relates to image contrast of T1-weighted (T1W) and T2-weighted (T2W) sequences on PMMR. Regressions were calculated using the method of least squares. Three readers judged visible changes of image contrast subjectively by consensus. Results: There was a positive relationship between temperature and contrast on T1-weighted (T1W) images and between temperature and the contrast of fat/muscle on T2-weighted (T2W) images. There was a negative relationship between temperature and the contrast of water/fat and water/muscle on T2W images. Subjectively, the influence of temperature became visible below 20 °C on T2W images, and below 10 °C on T1W images. Conclusion: Image contrast on PMMR depends on the temperature of a corpse. Radiologists involved in post mortem imaging must be aware of temperature-related changes in MR image contrast. To preserve technical quality, scanning corpses below 10 °C should be avoided.

  14. A method for the investigation of cholegraphic contrast media

    International Nuclear Information System (INIS)

    Otto, H.

    1982-01-01

    Isolated perfused rat livers were used for investigating possible interactions between two simultaneously injected contrast media, and which technique, using parenteral application of cholegraphic media, is optimal. The results show that excretion of a parenteral contrast medium is reduced by giving an oral contrast medium at the same time. Simultaneous administration of two different contrast media therefore does not result in improved diagnostic information. The effect depends on the dose, and a sufficiently long interval should be observed between giving an oral and a parenteral contrast medium. A comparison of excretion values following injection of a bolus and prolonged infusion shows higher biliary contrast concentration and increased excretion after a single injection. Comparing only the period after the infusion, no difference was found between these two methods of administration. The single injection offers pharmacokinetic advantages, but an infusion is better tolerated and has fewer side effects. A rapid infusion of 10 to 15 minutes is therefore recommended as the optimal means of administration. (orig.) [de

  15. Contrast-enhanced MR angiography

    International Nuclear Information System (INIS)

    Bosmans, H.; Marchal, G.

    1996-01-01

    Despite many optimizations, the current limitations of plain MR angiography include: Saturation that impairs the visualization of veins and arteries with slow flow and spin-dephasing signal voids in locations with turbulent flow. Recently, the use of contrast agents has been proposed to cope with these remaining problems. Because of induced shortening of the T1 of the blood, saturation in the blood vessels is overcome. As a result, arteries and veins are visualized with the same signal intensity, which makes the technique less flow-dependent. In combination with short T1-weighted acquisitions, today CE MRA can be obtained while the patient is holding his breath. This last approach is most promising for abdominal applications since the respiratory motion can be frozen. As these acquisitions also use very short echo times, spin dephasing can be reduced. In conclusion, the use of contrast agents has greatly increased the clinical usefulness of MR angiography. (orig.) [de

  16. Reconstruction methods for phase-contrast tomography

    Energy Technology Data Exchange (ETDEWEB)

    Raven, C.

    1997-02-01

    Phase contrast imaging with coherent x-rays can be distinguished in outline imaging and holography, depending on the wavelength {lambda}, the object size d and the object-to-detector distance r. When r << d{sup 2}{lambda}, phase contrast occurs only in regions where the refractive index fastly changes, i.e. at interfaces and edges in the sample. With increasing object-to-detector distance we come in the area of holographic imaging. The image contrast outside the shadow region of the object is due to interference of the direct, undiffracted beam and a beam diffracted by the object, or, in terms of holography, the interference of a reference wave with the object wave. Both, outline imaging and holography, offer the possibility to obtain three dimensional information of the sample in conjunction with a tomographic technique. But the data treatment and the kind of information one can obtain from the reconstruction is different.

  17. Information entropy of a time-dependent three-level trapped ion interacting with a laser field

    International Nuclear Information System (INIS)

    Abdel-Aty, Mahmoud

    2005-01-01

    Trapped and laser-cooled ions are increasingly used for a variety of modern high-precision experiments, frequency standard applications and quantum information processing. Therefore, in this communication we present a comprehensive analysis of the pattern of information entropy arising in the time evolution of an ion interacting with a laser field. A general analytic approach is proposed for a three-level trapped-ion system in the presence of the time-dependent couplings. By working out an exact analytic solution, we conclusively analyse the general properties of the von Neumann entropy and quantum information entropy. It is shown that the information entropy is affected strongly by the time-dependent coupling and exhibits long time periodic oscillations. This feature attributed to the fact that in the time-dependent region Rabi oscillation is time dependent. Using parameters corresponding to a specific three-level ionic system, a single beryllium ion in a RF-(Paul) trap, we obtain illustrative examples of some novel aspects of this system in the dynamical evolution. Our results establish an explicit relation between the exact information entropy and the entanglement between the multi-level ion and the laser field. We show that different nonclassical effects arise in the dynamics of the ionic population inversion, depending on the initial states of the vibrational motion/field and on the values of Lamb-Dicke parameter η

  18. Effects of contrast on smooth pursuit eye movements.

    Science.gov (United States)

    Spering, Miriam; Kerzel, Dirk; Braun, Doris I; Hawken, Michael J; Gegenfurtner, Karl R

    2005-05-20

    It is well known that moving stimuli can appear to move more slowly when contrast is reduced (P. Thompson, 1982). Here we address the question whether changes in stimulus contrast also affect smooth pursuit eye movements. Subjects were asked to smoothly track a moving Gabor patch. Targets varied in velocity (1, 8, and 15 deg/s), spatial frequency (0.1, 1, 4, and 8 c/deg), and contrast, ranging from just below individual thresholds to maximum contrast. Results show that smooth pursuit eye velocity gain rose significantly with increasing contrast. Below a contrast level of two to three times threshold, pursuit gain, acceleration, latency, and positional accuracy were severely impaired. Therefore, the smooth pursuit motor response shows the same kind of slowing at low contrast that was demonstrated in previous studies on perception.

  19. Ghrelin system in alcohol-dependent subjects: role of plasma ghrelin levels in alcohol drinking and craving.

    Science.gov (United States)

    Leggio, Lorenzo; Ferrulli, Anna; Cardone, Silvia; Nesci, Antonio; Miceli, Antonio; Malandrino, Noemi; Capristo, Esmeralda; Canestrelli, Benedetta; Monteleone, Palmiero; Kenna, George A; Swift, Robert M; Addolorato, Giovanni

    2012-03-01

    Animal studies suggest that the gut-brain peptide ghrelin plays an important role in the neurobiology of alcohol dependence (AD). Human studies show an effect of alcohol on ghrelin levels and a correlation between ghrelin levels and alcohol craving in alcoholics. This investigation consisted of two studies. Study 1 was a 12-week study with alcohol-dependent subjects, where plasma ghrelin determinations were assessed four times (T0-T3) and related to alcohol intake and craving [Penn Alcohol Craving Score (PACS) and Obsessive Compulsive Drinking Scale (OCDS)]. Serum growth hormone levels and assessment of the nutritional/metabolic status were also performed. Study 2 was a pilot case-control study to assess ghrelin gene polymorphisms (Arg51Gln and Leu72Met) in alcohol-dependent individuals. Study 1 showed no significant differences in ghrelin levels in the whole sample, while there was a statistical difference for ghrelin between non-abstinent and abstinent subjects. Baseline ghrelin levels were significantly and positively correlated with the PACS score at T1 and with all craving scores both at T2 and T3 (PACS, OCDS, obsessive and compulsive OCDS subscores). In Study 2, although there was a higher frequency of the Leu72Met ghrelin gene polymorphism in alcohol-dependent individuals, the distribution between healthy controls and alcohol dependent individuals was not statistically significant. This investigation suggests that ghrelin is potentially able to affect alcohol-seeking behaviors, such as alcohol drinking and craving, representing a new potential neuropharmacological target for AD. © 2011 The Authors, Addiction Biology © 2011 Society for the Study of Addiction.

  20. Effects of ocular aberrations on contrast detection in noise.

    Science.gov (United States)

    Liang, Bo; Liu, Rong; Dai, Yun; Zhou, Jiawei; Zhou, Yifeng; Zhang, Yudong

    2012-08-06

    We use adaptive optics (AO) techniques to manipulate the ocular aberrations and elucidate the effects of these ocular aberrations on contrast detection in a noisy background. The detectability of sine wave gratings at frequencies of 4, 8, and 16 circles per degree (cpd) was measured in a standard two-interval force-choice staircase procedure against backgrounds of various levels of white noise. The observer's ocular aberrations were either corrected with AO or left uncorrected. In low levels of external noise, contrast detection thresholds are always lowered by AO correction, whereas in high levels of external noise, they are generally elevated by AO correction. Higher levels of external noise are required to make this threshold elevation observable when signal spatial frequencies increase from 4 to 16 cpd. The linear-amplifier-model fit shows that mostly sampling efficiency and equivalent noise both decrease with AO correction. Our findings indicate that ocular aberrations could be beneficial for contrast detection in high-level noises. The implications of these findings are discussed.

  1. Comparison of renal toxicity after injection of CT contrast medium and MR contrast medium: change of renal function in acute renal failure rat models

    International Nuclear Information System (INIS)

    Han, Young min; Lee, Young Hwan; Kim, Sang Won; Jin, Kong Young; Kim, Won; Chung, Gyung Ho

    2002-01-01

    To determine renal toxicity through changes in renal function after the injection of CT and MRI contrast media into rats in which acute renal failure (ARF) was induced. To cause acute renal failure, the abdominal cavity of 110 male rats each weighing 250-300 gm was opened via a midline incision under anesthesia. Microvascular clamps were placed on both renal arteries and veins to completely block renal blood flow for 45 minutes, and were then removed, allowing blood flow to return to the kidneys. ARF, defined as a two-fold difference in the creatinine level before ARF and 48 hours after, was successfully induced in 60 of the rats. These were divided into two groups: one was injected with CT contrast medium and the other with MRI contrast medium. Each CT and MRI group was divided into a low dose (0.5 cc/kg, 0.2 ml/kg), standard dose (2 cc/kg, 0.8 ml/kg), and high dose (8 cc/kg, 3.2 ml/kg) sub-group; thus, there was a total of six groups with ten rats in each. Blood samples were obtained before ARF, 48 hours after, and 48 hours after contrast injection, and CT scanning and MRI were performed after blood sampling at 48 hours. In each group, creatinine levels 48 hours after contrast injection were compared by means of the ANOVA test. There were no significant differences in creatinine levels between the CT and MRI contrast medium groups (p=0.116), nor between the animals to which different doses of CT and MRI contrast medium, were administered. After both standard and high doses, CT and MRI provided good images. In rats in which acute renal failure was induced, renal function did not change according to whether CT or MRI contrast medium was injected. Thus, the two media induce similar levels of toxicity

  2. DEPENDENCE OF COUNTRY RISK COMPARED TO THE FOREIGN DEBT LEVEL

    Directory of Open Access Journals (Sweden)

    Angelica BĂCESCU-CĂRBUNARU

    2012-11-01

    Full Text Available The article presents some of the fundamental aspects of country risk’dependence compared to foreign debt level. Starting from external debt burden we analyze the usage of foreign loans, foreign debt bearing capacity as well as the availability of data regarding the external debt. Country risk represents the exposure to losses which may occur in a business with a foreign partner, caused by specific events that are, at least partially, controlled by the partner country’ government. Macroeconomic analysis of economic and financial component of country risk involves how this risk is influenced by government policy, by the economic role of government, bypricing strategies, investment priorities, financial structures, macroeconomic policy, by the ability to obtain foreign funds, the level of external debt as well as the liquidity and cash flows in that country.

  3. Recent advances in contrast-enhanced magnetic resonance angiography

    International Nuclear Information System (INIS)

    Meaney, J.F.M.; Goyen, M.

    2007-01-01

    Magnetic resonance angiography (MRA) provides a means of visualizing vascular structures noninvasively and is increasingly replacing conventional X-ray angiography in routine use. Contrast-enhanced MRA (CE-MRA), in which gadolinium contrast agents are used to shorten the T1 relaxation, offers increased resolution and higher signal-to-noise ratio compared with earlier flow-dependent [time-of-flight (TOF) or phase-contrast (PC)] techniques. Currently available contrast agents differ in their ability to lower T1 values, and hence the choice of contrast agent is an important consideration in the successful use of CE-MRA. Gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany) is the first of a new class of intravascular contrast agents. This agent is extensively (approximately 85%) and reversibly bound to human serum albumin and is retained within the vasculature thus allowing steady-state imaging to be perform-ed. An additional benefit is that gado0fosveset offers higher relaxivity compared with other contrast agents, thus giving a lower blood T1 values which also makes it ideal for first-pass imaging. Clinical trials have consistently shown that gadofosveset enhanced MRA is more sensitive, specific and accurate than time-of-flight MRA, gives fewer uninterpretable scans and affords greater diagnostic confidence. Intravascular contrast agents such as gadofosveset, therefore, offer the potential for improved vascular imaging. (orig.)

  4. The BDNF Val66Met polymorphism and plasma brain-derived neurotrophic factor levels in Han Chinese heroin-dependent patients.

    Science.gov (United States)

    Chen, Shiou-Lan; Lee, Sheng-Yu; Chang, Yun-Hsuan; Wang, Tzu-Yun; Chen, Shih-Heng; Chu, Chun-Hsien; Chen, Po See; Yang, Yen Kuang; Hong, Jau-Shyong; Lu, Ru-Band

    2015-02-02

    BDNF and its gene polymorphism may be important in synaptic plasticity and neuron survival, and may become a key target in the physiopathology of long-term heroin use. Thus, we investigated the relationships between brain-derived neurotrophic factor (BDNF) plasma concentrations and the BDNF Val66Met nucleotide polymorphism (SNP) in heroin-dependent patients. The pretreatment expression levels of plasma BDNF and the BDNF Val66Met SNP in 172 heroin-dependent patients and 102 healthy controls were checked. BDNF levels were significantly lower in patients (F = 52.28, p BDNF levels significantly different between Met/Met, Met/Val, and Val/Val carriers in each group, which indicated that the BDNF Val66Met SNP did not affect plasma BDNF levels in our participants. In heroin-dependent patients, plasma BDNF levels were negatively correlated with the length of heroin dependency. Long-term (>15 years) users had significantly lower plasma BDNF levels than did short-term (BDNF concentration in habitual heroin users are not affected by BDNF Val66Met gene variants, but by the length of the heroin dependency.

  5. Bounding the bias of contrastive divergence learning

    DEFF Research Database (Denmark)

    Fischer, Anja; Igel, Christian

    2011-01-01

    Optimization based on k-step contrastive divergence (CD) has become a common way to train restricted Boltzmann machines (RBMs). The k-step CD is a biased estimator of the log-likelihood gradient relying on Gibbs sampling. We derive a new upper bound for this bias. Its magnitude depends on k...

  6. Value of MR contrast media in image-guided body interventions.

    Science.gov (United States)

    Saeed, Maythem; Wilson, Mark

    2012-01-28

    In the past few years, there have been multiple advances in magnetic resonance (MR) instrumentation, in vivo devices, real-time imaging sequences and interventional procedures with new therapies. More recently, interventionists have started to use minimally invasive image-guided procedures and local therapies, which reduce the pain from conventional surgery and increase drug effectiveness, respectively. Local therapy also reduces the systemic dose and eliminates the toxic side effects of some drugs to other organs. The success of MR-guided procedures depends on visualization of the targets in 3D and precise deployment of ablation catheters, local therapies and devices. MR contrast media provide a wealth of tissue contrast and allows 3D and 4D image acquisitions. After the development of fast imaging sequences, the clinical applications of MR contrast media have been substantially expanded to include pre- during- and post-interventions. Prior to intervention, MR contrast media have the potential to localize and delineate pathologic tissues of vital organs, such as the brain, heart, breast, kidney, prostate, liver and uterus. They also offer other options such as labeling therapeutic agents or cells. During intervention, these agents have the capability to map blood vessels and enhance the contrast between the endovascular guidewire/catheters/devices, blood and tissues as well as direct therapies to the target. Furthermore, labeling therapeutic agents or cells aids in visualizing their delivery sites and tracking their tissue distribution. After intervention, MR contrast media have been used for assessing the efficacy of ablation and therapies. It should be noted that most image-guided procedures are under preclinical research and development. It can be concluded that MR contrast media have great value in preclinical and some clinical interventional procedures. Future applications of MR contrast media in image-guided procedures depend on their safety, tolerability

  7. Relations between vegetation and water level in groundwater dependent terrestrial ecosystems (GWDTEs)

    DEFF Research Database (Denmark)

    Munch Johansen, Ole; Andersen, Dagmar Kappel; Ejrnæs, Rasmus

    2018-01-01

    , management and conservation of fens are constrained by limited knowledge on the relations between vegetation and measurable hydrological conditions. This study investigates the relations between vegetation and water level dynamics in groundwater dependent wetlands in Denmark. A total of 35 wetland sites...... across Denmark were included in the study. The sites represent a continuum of wetlands with respect to vegetation and hydrological conditions. Water level was measured continuously using pressure transducers at each site. Metrics expressing different hydrological characteristics, such as mean water level...... and low and high water level periods, were calculated based on the water level time series. A complete plant species list was recorded in plots covering 78.5 m2 at each site. Community metrics such as total number of species and the number of bryophytes were generated from the species lists and Ellenberg...

  8. The effects of X-ray energy and an iodine-based contrast agent on chromosome aberrations

    International Nuclear Information System (INIS)

    Matsubara, Sho; Kubota, Nobuo; Katoh, Tsuguhisa; Yoshino, Norio; Sasaki, Takehito; Sasaki, Masao S.

    1994-01-01

    A study was undertaken to evaluate the effect of combining irradiation with X rays of various energies and an iodine-based contrast agent on the induction of chromosome aberrations in the peripheral lymphocytes of blood samples taken from healthy young donors. Although no enhancement of the effect of radiation was induced when blood samples with the iodine-based contrast agent were given 35 kV X irradiation, an 80 kV X-ray exposure induced an enhanced level of chromosome aberrations, and a 250 kV X irradiation, an enhancement of the frequencies of chromosome aberrations was seen in blood samples with the iodine-based contrast agent, especially when a Lucite phantom was employed in studies to increase the scattered rays. It was thus shown by microdosimetric analysis that X irradiation combined with an iodine-based contrast agent causes an enhancement of the absorbed radiation dose, which is dependent on the X-ray energies employed. This phenomenon may have clinical use in the radiotherapeutic management of tumors, although further extensive studies of tumor vascularity must be pursued before this can be applied clinically. 21 refs., 8 figs., 3 tabs

  9. Neurophysiological model of tinnitus: dependence of the minimal masking level on treatment outcome.

    Science.gov (United States)

    Jastreboff, P J; Hazell, J W; Graham, R L

    1994-11-01

    Validity of the neurophysiological model of tinnitus (Jastreboff, 1990), outlined in this paper, was tested on data from multicenter trial of tinnitus masking (Hazell et al., 1985). Minimal masking level, intensity match of tinnitus, and the threshold of hearing have been evaluated on a total of 382 patients before and after 6 months of treatment with maskers, hearing aids, or combination devices. The data has been divided into categories depending on treatment outcome and type of approach used. Results of analysis revealed that: i) the psychoacoustical description of tinnitus does not possess a predictive value for the outcome of the treatment; ii) minimal masking level changed significantly depending on the treatment outcome, decreasing on average by 5.3 dB in patients reporting improvement, and increasing by 4.9 dB in those whose tinnitus remained the same or worsened; iii) 73.9% of patients reporting improvement had their minimal masking level decreased as compared with 50.5% for patients not showing improvement, which is at the level of random change; iv) the type of device used has no significant impact on the treatment outcome and minimal masking level change; v) intensity match and threshold of hearing did not exhibit any significant changes which can be related to treatment outcome. These results are fully consistent with the neurophysiological interpretation of mechanisms involved in the phenomenon of tinnitus and its alleviation.

  10. Intravenous Contrast Medium Administration for Computed Tomography Scan in Emergency: A Possible Cause of Contrast-Induced Nephropathy

    International Nuclear Information System (INIS)

    Sonhaye, Lantam; Kolou, Bérésa; Tchaou, Mazamaesso; Amadou, Abdoulatif; Assih, Kouméabalo; N'Timon, Bidamin; Adambounou, Kokou; Agoda-Koussema, Lama; Adjenou, Komlavi; N'Dakena, Koffi

    2015-01-01

    The goal of this study was to assess risk for CIN after CT Scan during an emergency and to identify risk factors for the patient. Prospective review of all patients admitted to the emergency room (ER) of the Teaching Hospital of Lomé (Togo) during a 2-year period. CIN was defined as an increase in serum creatinine by 0.5 mg/dL from admission after undergoing CT Scan with intravenous contrast. A total of 620 patients underwent a CT Scan in the emergency room using intravenous contrast and 672 patients took the CT Scan without intravenous contrast. Out of the patients who received intravenous contrast for CT Scan, three percent of them developed CIN during their admission. Moreover, upon discharge no patient had continued renal impairment. No patient required dialysis during their admission. The multivariate analysis of all patients who had serial creatinine levels (including those who did not receive any contrast load) shows no increased risk for acute kidney injury associated intravenous contrast (odds ratio = 0.619, p value = 0.886); only diabetes remains independent risk factor of acute kidney injury (odds ratio = 6.26, p value = 0.031)

  11. DIFFERENCES REGARDING SELF-ESTEEM AND THE COMMUNICATION STYLE DEPENDING ON THE LEVEL OF EDUCATION

    Directory of Open Access Journals (Sweden)

    Georgeta PÂNIȘOARĂ

    2015-12-01

    Full Text Available The present paper aims to study the differences in self-esteem and the communication style, depending on the level of education (at high school and university subjects. It is analyzed also how the positive self-esteem can correlate with a style of communication and assertively-positive approach. The participants are 120 subjects, 60 high school students and 60 students. The data was collected using two instruments: the Rosenberg questionnaire and a questionnaire on communication style. The data analyzed using a t test for independent samples and a Pearson correlation test with SPSS statistical software. The results show that there are differences regarding the self-esteem and the communication style depending on the level of education.

  12. A Review: Radiographic Iodinated Contrast Media-Induced Thyroid Dysfunction

    Science.gov (United States)

    Leung, Angela M.; Braverman, Lewis E.; Brent, Gregory A.; Pearce, Elizabeth N.

    2015-01-01

    Context: Thyroid hormone production is dependent on adequate iodine intake. Excess iodine is generally well-tolerated, but thyroid dysfunction can occur in susceptible individuals after excess iodine exposure. Radiological iodinated contrast media represent an increasingly common source of excess iodine. Objective: This review will discuss the thyroidal response after acute exposure to excess iodine; contrast iodine-induced thyroid dysfunction; risks of iodine-induced thyroid dysfunction in vulnerable populations, such as the fetus, neonate, and patients with impaired renal function; and recommendations for the assessment and treatment of contrast iodine-induced thyroid dysfunction. Methods: Data for this review were identified by searching PubMed, Google Scholar, and references from relevant articles from 1948 to 2014. Conclusions: With the increase in the use of computed tomography scans in the United States, there is increasing risk of contrast-induced thyroid dysfunction. Patients at risk of developing iodine-induced thyroid dysfunction should be closely monitored after receiving iodinated contrast media and should be treated as needed. PMID:25375985

  13. Asymptotic expansions for high-contrast elliptic equations

    KAUST Repository

    Calo, Victor M.; Efendiev, Yalchin R.; Galvis, Juan

    2014-01-01

    In this paper, we present a high-order expansion for elliptic equations in high-contrast media. The background conductivity is taken to be one and we assume the medium contains high (or low) conductivity inclusions. We derive an asymptotic expansion with respect to the contrast and provide a procedure to compute the terms in the expansion. The computation of the expansion does not depend on the contrast which is important for simulations. The latter allows avoiding increased mesh resolution around high conductivity features. This work is partly motivated by our earlier work in [Domain decomposition preconditioners for multiscale flows in high-contrast media, Multiscale Model Simul. 8 (2010) 1461-1483] where we design efficient numerical procedures for solving high-contrast problems. These multiscale approaches require local solutions and our proposed high-order expansion can be used to approximate these local solutions inexpensively. In the case of a large-number of inclusions, the proposed analysis can help to design localization techniques for computing the terms in the expansion. In the paper, we present a rigorous analysis of the proposed high-order expansion and estimate the remainder of it. We consider both high-and low-conductivity inclusions. © 2014 World Scientific Publishing Company.

  14. Asymptotic expansions for high-contrast elliptic equations

    KAUST Repository

    Calo, Victor M.

    2014-03-01

    In this paper, we present a high-order expansion for elliptic equations in high-contrast media. The background conductivity is taken to be one and we assume the medium contains high (or low) conductivity inclusions. We derive an asymptotic expansion with respect to the contrast and provide a procedure to compute the terms in the expansion. The computation of the expansion does not depend on the contrast which is important for simulations. The latter allows avoiding increased mesh resolution around high conductivity features. This work is partly motivated by our earlier work in [Domain decomposition preconditioners for multiscale flows in high-contrast media, Multiscale Model Simul. 8 (2010) 1461-1483] where we design efficient numerical procedures for solving high-contrast problems. These multiscale approaches require local solutions and our proposed high-order expansion can be used to approximate these local solutions inexpensively. In the case of a large-number of inclusions, the proposed analysis can help to design localization techniques for computing the terms in the expansion. In the paper, we present a rigorous analysis of the proposed high-order expansion and estimate the remainder of it. We consider both high-and low-conductivity inclusions. © 2014 World Scientific Publishing Company.

  15. Epithelial cell biocompatibility of silica nanospheres for contrast-enhanced ultrasound molecular imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chiriaco, Fernanda; Conversano, Francesco; Soloperto, Giulia; Casciaro, Ernesto [Institute of Clinical Physiology, Bioengineering Division, National Research Council (Italy); Ragusa, Andrea [National Nanotechnology Laboratory of CNR-NANO (Italy); Sbenaglia, Enzo Antonio; Dipaola, Lucia [Institute of Clinical Physiology, Bioengineering Division, National Research Council (Italy); Casciaro, Sergio, E-mail: sergio.casciaro@cnr.it [Istituto di Fisiologia Clinica (CNR-IFC) c/o Campus Universitario Ecotekne, Consiglio Nazionale delle Ricerche (Italy)

    2013-07-15

    Nanosized particles are receiving increasing attention as future contrast agents (CAs) for ultrasound (US) molecular imaging, possibly decorated on its surface with biological recognition agents for targeted delivery and deposition of therapeutics. In particular, silica nanospheres (SiNSs) have been demonstrated to be feasible in terms of contrast enhancement on conventional US systems. In this work, we evaluated the cytotoxicity of SiNSs on breast cancer (MCF-7) and HeLa (cervical cancer) cells employing NSs with sizes ranging from 160 to 330 nm and concentration range of 1.5-5 mg/mL. Cell viability was evaluated in terms of size, dose and time dependence, performing the MTT reduction assay with coated and uncoated SiNSs. Whereas uncoated SiNSs caused a variable significant decrease in cell viability on both cell lines mainly depending on size and exposure time, PEGylated SiNSs (SiNSs-PEG) exhibit a high level of biocompatibility. In fact, after 72-h incubation, viability of both cell types was above the cutoff value of 70 % at concentration up to 5 mg/mL. We also investigated the acoustical behavior of coated and uncoated SiNSs within conventional diagnostic US fields in order to determine a suitable configuration, in terms of particle size and concentration, for their employment as targetable CAs. Our results indicate that the employment of SiNSs with diameters around 240 nm assures the most effective contrast enhancement even at the lowest tested concentration, coupled with the possibility of targeting all tumor tissues, being the SiNSs still in a size range where reticuloendothelial system trapping effect is relatively low.

  16. Epithelial cell biocompatibility of silica nanospheres for contrast-enhanced ultrasound molecular imaging

    International Nuclear Information System (INIS)

    Chiriacò, Fernanda; Conversano, Francesco; Soloperto, Giulia; Casciaro, Ernesto; Ragusa, Andrea; Sbenaglia, Enzo Antonio; Dipaola, Lucia; Casciaro, Sergio

    2013-01-01

    Nanosized particles are receiving increasing attention as future contrast agents (CAs) for ultrasound (US) molecular imaging, possibly decorated on its surface with biological recognition agents for targeted delivery and deposition of therapeutics. In particular, silica nanospheres (SiNSs) have been demonstrated to be feasible in terms of contrast enhancement on conventional US systems. In this work, we evaluated the cytotoxicity of SiNSs on breast cancer (MCF-7) and HeLa (cervical cancer) cells employing NSs with sizes ranging from 160 to 330 nm and concentration range of 1.5–5 mg/mL. Cell viability was evaluated in terms of size, dose and time dependence, performing the MTT reduction assay with coated and uncoated SiNSs. Whereas uncoated SiNSs caused a variable significant decrease in cell viability on both cell lines mainly depending on size and exposure time, PEGylated SiNSs (SiNSs-PEG) exhibit a high level of biocompatibility. In fact, after 72-h incubation, viability of both cell types was above the cutoff value of 70 % at concentration up to 5 mg/mL. We also investigated the acoustical behavior of coated and uncoated SiNSs within conventional diagnostic US fields in order to determine a suitable configuration, in terms of particle size and concentration, for their employment as targetable CAs. Our results indicate that the employment of SiNSs with diameters around 240 nm assures the most effective contrast enhancement even at the lowest tested concentration, coupled with the possibility of targeting all tumor tissues, being the SiNSs still in a size range where reticuloendothelial system trapping effect is relatively low

  17. Continuum corrections to the level density and its dependence on excitation energy, n-p asymmetry, and deformation

    International Nuclear Information System (INIS)

    Charity, R.J.; Sobotka, L.G.

    2005-01-01

    In the independent-particle model, the nuclear level density is determined from the neutron and proton single-particle level densities. The single-particle level density for the positive-energy continuum levels is important at high excitation energies for stable nuclei and at all excitation energies for nuclei near the drip lines. This single-particle level density is subdivided into compound-nucleus and gas components. Two methods are considered for this subdivision: In the subtraction method, the single-particle level density is determined from the scattering phase shifts. In the Gamov method, only the narrow Gamov states or resonances are included. The level densities calculated with these two methods are similar; both can be approximated by the backshifted Fermi-gas expression with level-density parameters that are dependent on A, but with very little dependence on the neutron or proton richness of the nucleus. However, a small decrease in the level-density parameter is predicted for some nuclei very close to the drip lines. The largest difference between the calculations using the two methods is the deformation dependence of the level density. The Gamov method predicts a very strong peaking of the level density at sphericity for high excitation energies. This leads to a suppression of deformed configurations and, consequently, the fission rate predicted by the statistical model is reduced in the Gamov method

  18. [Cross-sectional study of informal caregiver burden and the determinants related to the care of dependent persons].

    Science.gov (United States)

    Rodríguez-González, Ana María; Rodríguez-Míguez, Eva; Duarte-Pérez, Ana; Díaz-Sanisidro, Eduardo; Barbosa-Álvarez, Ángel; Clavería, Ana

    2017-03-01

    To describe the burden of informal carers of dependent people and to identify related variables. Descriptive observational cross-sectional study. Primary Health Care in the southern area of Pontevedra. 97 caregivers of dependent persons. We collected socioeconomic data and health conditions from caregivers and dependent persons, time spent on the daily care and caregiver burden (Zarit abbreviate) through a personal interview. Besides the description of the sample-including their burden level-, a contrast mean was used to identify characteristics that influenced in punctuation of Zarit scale. A logistic regression was used to analyse characteristics that increase the likelihood to experiment burden. 61.9% of caregivers are subject to intense burden. The item on the scale which contributes most to the caregiver burden is the lack of time for oneself, followed by the negative effects of interpersonal relationships. Contrast means shows that degree of relationship, number of care hours, caregiver health and aggressiveness of dependent persons produce significant differences in Zarit scale. Physic and psychological health of caregivers and aggressiveness of dependent persons is associated with the likelihood of developing caregiver burden. Informal caregivers of dependent persons show a high level of burden, both related to their characteristics and those of the dependent persons. Caregiver burden rethinks the need for public policies focused on dependence to adopt an integrative caregiver-dependent vision. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  19. [Diagnostic Significance of BAT in Anaphylaxis to Non-ionic Contrast Media].

    Science.gov (United States)

    Zhang, Hao-yue; Xu, Su-jun; Tang, Xiao-xian; Niu, Ji-jun; Guo, Xiang-jie; Gao, Cai-rong

    2015-06-01

    To investigate the diagnostic significance of basophil activation test (BAT) in anaphylaxis to non-ionic contrast media through testing the content of CD63, mast cell-carboxypeptidase A3 (MC-CPA3), and terminal complement complex SC5b-9 of the individuals by testing their levels in the normal immune group and the anaphylaxis groups to β-lactam drugs and non -ionic contrast media. The CD63 expression of basophilic granulocyte in blood was detected by flow cytometry. The levels of MC-CPA3 in blood serum and SC5b-9 in blood plasma were detected by ELISA. The CD63 expression of basophilic granulocyte in blood, the levels of MC-CPA3 and SC5b-9 of anaphylaxis to non-ionic contrast media and β-lactam drugs were significantly higher than that in normal immune group (P contrast media. BAT can be used to diagnose the anaphylaxis to non-ionic contrast media.

  20. Population-Level Density Dependence Influences the Origin and Maintenance of Parental Care.

    Science.gov (United States)

    Reyes, Elijah; Thrasher, Patsy; Bonsall, Michael B; Klug, Hope

    2016-01-01

    Parental care is a defining feature of animal breeding systems. We now know that both basic life-history characteristics and ecological factors influence the evolution of care. However, relatively little is known about how these factors interact to influence the origin and maintenance of care. Here, we expand upon previous work and explore the relationship between basic life-history characteristics (stage-specific rates of mortality and maturation) and the fitness benefits associated with the origin and the maintenance of parental care for two broad ecological scenarios: the scenario in which egg survival is density dependent and the case in which adult survival is density dependent. Our findings suggest that high offspring need is likely critical in driving the origin, but not the maintenance, of parental care regardless of whether density dependence acts on egg or adult survival. In general, parental care is more likely to result in greater fitness benefits when baseline adult mortality is low if 1) egg survival is density dependent or 2) adult mortality is density dependent and mutant density is relatively high. When density dependence acts on egg mortality, low rates of egg maturation and high egg densities are less likely to lead to strong fitness benefits of care. However, when density dependence acts on adult mortality, high levels of egg maturation and increasing adult densities are less likely to maintain care. Juvenile survival has relatively little, if any, effect on the origin and maintenance of egg-only care. More generally, our results suggest that the evolution of parental care will be influenced by an organism's entire life history characteristics, the stage at which density dependence acts, and whether care is originating or being maintained.

  1. Variational contrast enhancement guided by global and local contrast measurements for single-image defogging

    Science.gov (United States)

    Zhou, Li; Bi, Du-Yan; He, Lin-Yuan

    2015-01-01

    The visibility of images captured in foggy conditions is impaired severely by a decrease in the contrasts of objects and veiling with a characteristic gray hue, which may limit the performance of visual applications out of doors. Contrast enhancement together with color restoration is a challenging mission for conventional fog-removal methods, as the degrading effect of fog is largely dependent on scene depth information. Nowadays, people change their minds by establishing a variational framework for contrast enhancement based on a physically based analytical model, unexpectedly resulting in color distortion, dark-patch distortion, or fuzzy features of local regions. Unlike previous work, our method treats an atmospheric veil as a scattering disturbance and formulates a foggy image as an energy functional minimization to estimate direct attenuation, originating from the work of image denoising. In addition to a global contrast measurement based on a total variation norm, an additional local measurement is designed in that optimal problem for the purpose of digging out more local details as well as suppressing dark-patch distortion. Moreover, we estimate the airlight precisely by maximization with a geometric constraint and a natural image prior in order to protect the faithfulness of the scene color. With the estimated direct attenuation and airlight, the fog-free image can be restored. Finally, our method is tested on several benchmark and realistic images evaluated by two assessment approaches. The experimental results imply that our proposed method works well compared with the state-of-the-art defogging methods.

  2. Order Level Inventory Models for Deteriorating Seasonable/Fashionable Products with Time Dependent Demand and Shortages

    Directory of Open Access Journals (Sweden)

    K. Skouri

    2009-01-01

    Full Text Available An order level inventory model for seasonable/fashionable products subject to a period of increasing demand followed by a period of level demand and then by a period of decreasing demand rate (three branches ramp type demand rate is considered. The unsatisfied demand is partially backlogged with a time dependent backlogging rate. In addition, the product deteriorates with a time dependent, namely, Weibull, deterioration rate. The model is studied under the following different replenishment policies: (a starting with no shortages and (b starting with shortages. The optimal replenishment policy for the model is derived for both the above mentioned policies.

  3. Investigating the procedural variables that determine whether rats will display negative anticipatory contrast or positive induction.

    Science.gov (United States)

    Weatherly, Jeffrey N; Nurnberger, Jeri T; Hanson, Brent C

    2005-08-31

    Previous studies have demonstrated that consumption of a low-valued food substance may decrease if access to a high-valued substance will soon be available (negative anticipatory contrast). Research has also demonstrated that responding for a low-valued reinforcer may increase if responding for a high-valued reinforcer will soon be possible (positive induction). The present experiment employed rats to respond in a procedure similar to that typically used to produce negative anticipatory contrast. The goal was to determine what factors contribute to when a contrast or an induction effect will occur. Based on previous research, the influence of auditory cues, temporal delays, food deprivation, and location of substance delivery were investigated. Auditory cues and temporal delays did little to influence whether subjects increased or decreased their consumption of 1% sucrose when access to 32% sucrose was upcoming. The appearance of contrast or induction was related to level of deprivation, with deprivation promoting induction. Which effect occurred also depended on whether subjects consumed the two substances from one spout in one location (induction) or from two different spouts in two different locations (contrast). The present results help identify the procedural link(s) between these two effects. They also provide insight to why positive induction may occur (i.e., higher-order place conditioning).

  4. Reducing the substrate dependent scanner leveling effect in low-k1 contact printing

    Science.gov (United States)

    Chang, C. S.; Tseng, C. F.; Huang, C. H.; Yang, Elvis; Yang, T. H.; Chen, K. C.

    2015-03-01

    As the scaling down of design rule for high-density memory device, the small depth of focus (DoF) budget may be deteriorated by focus leveling errors, which arises in unpredicted reflectivity from multilayer structures on the topographic wafer. The leveling sensors of ASML scanner use near infrared (NIR) range wavelength which can penetrate through most of films using in semiconductor fabrication such as photo-resist, bottom anti reflective coating (BARC) and dielectric materials. Consequently, the reflected light from underlying substructures would disturb leveling sensors from accurate leveling. The different pattern densities and layout characteristics between array and periphery of a memory chip are expected to result in different leveling signals. Furthermore, the process dependent variations between wafer central and edge areas are also considered to yield different leveling performances during wafer exposure. In this study, lower blind contact immunity was observed for peripheral contacts comparing to the array contacts especially around wafer edge region. In order to overcome this problem, a series of investigations have been carried out. The wafer edge leveling optimization through circuit dependent focus edge clearance (CDFEC) option doesn't get improvement. Air gauge improved process leveling (AGILE) function of ASML immersion scanner doesn't show improved result either. The ILD uniformity improvement and step height treatments around wafer edge such as edge exclusion of film deposition and bevel etching are also ineffective to mitigate the blind contact problem of peripheral patterns. Altering the etch hard-mask stack is finally found to be an effective approach to alleviate the issue. For instance, through either containing high temperature deposition advanced patterning film (APF) in the hard-mask or inserting higher opaque film such as amorphous Si in between the hard-mask stack.

  5. Panel Data with Cross-Sectional Dependence Characterized by a Multi-Level Factor Structure

    DEFF Research Database (Denmark)

    Rodríguez-Caballero, Carlos Vladimir

    A panel data model with a multi-level cross-sectional dependence is proposed. The factor structure is driven by top-level common factors as well as non-pervasive factors. I propose a simple method to filter out the full factor structure that overcomes limitations in standard procedures which may...... mix up both levels of unobservable factors and may hamper the identification of the model. The model covers both stationary and non-stationary cases and takes into account other relevant features that make the model well suited to the analysis of many types of time series frequently addressed...

  6. Contrast-enhanced spectral mammography with a photon-counting detector.

    Science.gov (United States)

    Fredenberg, Erik; Hemmendorff, Magnus; Cederström, Björn; Aslund, Magnus; Danielsson, Mats

    2010-05-01

    Spectral imaging is a method in medical x-ray imaging to extract information about the object constituents by the material-specific energy dependence of x-ray attenuation. The authors have investigated a photon-counting spectral imaging system with two energy bins for contrast-enhanced mammography. System optimization and the potential benefit compared to conventional non-energy-resolved absorption imaging was studied. A framework for system characterization was set up that included quantum and anatomical noise and a theoretical model of the system was benchmarked to phantom measurements. Optimal combination of the energy-resolved images corresponded approximately to minimization of the anatomical noise, which is commonly referred to as energy subtraction. In that case, an ideal-observer detectability index could be improved close to 50% compared to absorption imaging in the phantom study. Optimization with respect to the signal-to-quantum-noise ratio, commonly referred to as energy weighting, yielded only a minute improvement. In a simulation of a clinically more realistic case, spectral imaging was predicted to perform approximately 30% better than absorption imaging for an average glandularity breast with an average level of anatomical noise. For dense breast tissue and a high level of anatomical noise, however, a rise in detectability by a factor of 6 was predicted. Another approximately 70%-90% improvement was found to be within reach for an optimized system. Contrast-enhanced spectral mammography is feasible and beneficial with the current system, and there is room for additional improvements. Inclusion of anatomical noise is essential for optimizing spectral imaging systems.

  7. Contrast-enhanced spectral mammography with a photon-counting detector

    Energy Technology Data Exchange (ETDEWEB)

    Fredenberg, Erik; Hemmendorff, Magnus; Cederstroem, Bjoern; Aaslund, Magnus; Danielsson, Mats [Department of Physics, Royal Institute of Technology, AlbaNova, SE-106 91 Stockholm (Sweden); Sectra Mamea AB, Smidesvaegen 5, SE-171 41 Solna (Sweden); Department of Physics, Royal Institute of Technology, AlbaNova, SE-106 91 Stockholm (Sweden); Sectra Mamea AB, Smidesvaegen 5, SE-171 41 Solna (Sweden); Department of Physics, Royal Institute of Technology, AlbaNova, SE-106 91 Stockholm (Sweden)

    2010-05-15

    Purpose: Spectral imaging is a method in medical x-ray imaging to extract information about the object constituents by the material-specific energy dependence of x-ray attenuation. The authors have investigated a photon-counting spectral imaging system with two energy bins for contrast-enhanced mammography. System optimization and the potential benefit compared to conventional non-energy-resolved absorption imaging was studied. Methods: A framework for system characterization was set up that included quantum and anatomical noise and a theoretical model of the system was benchmarked to phantom measurements. Results: Optimal combination of the energy-resolved images corresponded approximately to minimization of the anatomical noise, which is commonly referred to as energy subtraction. In that case, an ideal-observer detectability index could be improved close to 50% compared to absorption imaging in the phantom study. Optimization with respect to the signal-to-quantum-noise ratio, commonly referred to as energy weighting, yielded only a minute improvement. In a simulation of a clinically more realistic case, spectral imaging was predicted to perform approximately 30% better than absorption imaging for an average glandularity breast with an average level of anatomical noise. For dense breast tissue and a high level of anatomical noise, however, a rise in detectability by a factor of 6 was predicted. Another {approx}70%-90% improvement was found to be within reach for an optimized system. Conclusions: Contrast-enhanced spectral mammography is feasible and beneficial with the current system, and there is room for additional improvements. Inclusion of anatomical noise is essential for optimizing spectral imaging systems.

  8. Temperature Dependence of Apparent Respiratory Quotients and Oxygen Penetration Depth in Contrasting Lake Sediments

    Science.gov (United States)

    Sobek, Sebastian; Gudasz, Cristian; Koehler, Birgit; Tranvik, Lars J.; Bastviken, David; Morales-Pineda, María.

    2017-11-01

    Lake sediments constitute an important compartment in the carbon cycle of lakes, by burying carbon over geological timescales and by production and emission of greenhouse gases. The degradation of organic carbon (OC) in lake sediments is linked to both temperature and oxygen (O2), but the interactive nature of this regulation has not been studied in lake sediments in a quantitative way. We present the first systematic investigation of the effects of temperature on the apparent respiratory quotient (RQ, i.e., the molar ratio between carbon dioxide (CO2) production and O2 consumption) in two contrasting lake sediments. Laboratory incubations of sediment cores of a humic lake and an eutrophic lake across a 1-21°C temperature gradient over 157 days revealed that both CO2 production and O2 consumption were positively, exponentially, and similarly dependent on temperature. The apparent RQ differed significantly between the lake sediments (0.63 ± 0.26 and 0.99 ± 0.28 in the humic and the eutrophic lake, respectively; mean ± SD) and was significantly and positively related to temperature. The O2 penetration depth into the sediment varied by a factor of 2 over the 1-21°C temperature range and was significantly, negatively, and similarly related to temperature in both lake sediments. Accordingly, increasing temperature may influence the overall extent of OC degradation in lake sediments by limiting O2 supply to aerobic microbial respiration to the topmost sediment layer, resulting in a concomitant shift to less effective anaerobic degradation pathways. This suggests that temperature may represent a key controlling factor of the OC burial efficiency in lake sediments.

  9. Suprathreshold contrast summation over area using drifting gratings.

    Science.gov (United States)

    McDougall, Thomas J; Dickinson, J Edwin; Badcock, David R

    2018-04-01

    This study investigated contrast summation over area for moving targets applied to a fixed-size contrast pedestal-a technique originally developed by Meese and Summers (2007) to demonstrate strong spatial summation of contrast for static patterns at suprathreshold contrast levels. Target contrast increments (drifting gratings) were applied to either the entire 20% contrast pedestal (a full fixed-size drifting grating), or in the configuration of a checkerboard pattern in which the target increment was applied to every alternate check region. These checked stimuli are known as "Battenberg patterns" and the sizes of the checks were varied (within a fixed overall area), across conditions, to measure summation behavior. Results showed that sensitivity to an increment covering the full pedestal was significantly higher than that for the Battenberg patterns (areal summation). Two observers showed strong summation across all check sizes (0.71°-3.33°), and for two other observers the summation ratio dropped to levels consistent with probability summation once check size reached 2.00°. Therefore, areal summation with moving targets does operate at high contrast, and is subserved by relatively large receptive fields covering a square area extending up to at least 3.33° × 3.33° for some observers. Previous studies in which the spatial structure of the pedestal and target covaried were unable to demonstrate spatial summation, potentially due to increasing amounts of suppression from gain-control mechanisms which increases as pedestal size increases. This study shows that when this is controlled, by keeping the pedestal the same across all conditions, extensive summation can be demonstrated.

  10. Contrast Induced by a Static Magnetic Field for Improved Detection in Nanodiamond Fluorescence Microscopy

    Science.gov (United States)

    Singam, Shashi K. R.; Motylewski, Jaroslaw; Monaco, Antonina; Gjorgievska, Elena; Bourgeois, Emilie; Nesládek, Milos; Giugliano, Michele; Goovaerts, Etienne

    2016-12-01

    Diamond nanoparticles with negatively charged nitrogen-vacancy (NV) centers are highly efficient nonblinking emitters that exhibit spin-dependent intensity. An attractive application of these emitters is background-free fluorescence microscopy exploiting the fluorescence quenching induced either by resonant microwaves (RMWs) or by an applied static magnetic field (SMF). Here, we compare RMW- and SMF-induced contrast measurements over a wide range of optical excitation rates for fluorescent nanodiamonds (FNDs) and for NV centers shallowly buried under the (100)-oriented surface of a diamond single crystal (SC). Contrast levels are found to be systematically lower in the FNDs than in the SC. At low excitation rates, the RMW contrast initially rises to a maximum (up to 7% in FNDs and 13% in the SC) but then decreases steadily at higher intensities. Conversely, the SMF contrast increases from approximately 12% at low excitation rates to high values of 20% and 38% for the FNDs and SC, respectively. These observations are well described in a rate-equations model for the charged NV defect using parameters in good agreement with the literature. The SMF approach yields higher induced contrast in image collection under commonly applied optical excitation. Unlike the RMW method, there is no thermal load exerted on the aqueous media in biological samples in the SMF approach. We demonstrate imaging by SMF-induced contrast in neuronal cultures incorporating FNDs (i) in a setup for patch-clamp experiments in parallel with differential-interference-contrast microscopy, (ii) after a commonly used staining procedure as an illustration of the high selectivity against background fluorescence, and (iii) in a confocal fluorescence microscope in combination with bright-field microscopy.

  11. Laser projection using generalized phase contrast

    DEFF Research Database (Denmark)

    Glückstad, Jesper; Palima, Darwin; Rodrigo, Peter John

    2007-01-01

    is introduced. An arbitrary phase shift filter eliminates the need for high-frequency modulation and conjugate phase encoding. This lowers device performance requirements and allows practical implementation with currently available dynamic spatial light modulators. (c) 2007 Optical Society of America.......We demonstrate experimental laser projection of a gray-level photographic image with 74% light efficiency using the generalized phase contrast (GPC) method. In contrast with a previously proposed technique [Alonzo et al., New J. Phys. 9, 132 (2007)], a new approach to image construction via GPC...

  12. Simultaneous contrast: evidence from licking microstructure and cross-solution comparisons.

    Science.gov (United States)

    Dwyer, Dominic M; Lydall, Emma S; Hayward, Andrew J

    2011-04-01

    The microstructure of rats' licking responses was analyzed to investigate both "classic" simultaneous contrast (e.g., Flaherty & Largen, 1975) and a novel discrete-trial contrast procedure where access to an 8% test solution of sucrose was preceded by a sample of either 2%, 8%, or 32% sucrose (Experiments 1 and 2, respectively). Consumption of a given concentration of sucrose was higher when consumed alongside a low rather than high concentration comparison solution (positive contrast) and consumption of a given concentration of sucrose was lower when consumed alongside a high rather than a low concentration comparison solution (negative contrast). Furthermore, positive contrast increased the size of lick clusters while negative contrast decreased the size of lick clusters. Lick cluster size has a positive monotonic relationship with the concentration of palatable solutions and so positive and negative contrasts produced changes in lick cluster size that were analogous to raising or lowering the concentration of the test solution respectively. Experiment 3 utilized the discrete-trial procedure and compared contrast between two solutions of the same type (sucrose-sucrose or maltodextrin-maltodextrin) or contrast across solutions (sucrose-maltodextrin or maltodextrin-sucrose). Contrast effects on consumption were present, but reduced in size, in the cross-solution conditions. Moreover, lick cluster sizes were not affected at all by cross-solution contrasts as they were by same-solution contrasts. These results are consistent with the idea that simultaneous contrast effects depend, at least partially, on sensory mechanisms.

  13. Functional Consequences of Intracellular Proline Levels Manipulation Affecting PRODH/POX-Dependent Pro-Apoptotic Pathways in a Novel in Vitro Cell Culture Model.

    Science.gov (United States)

    Zareba, Ilona; Surazynski, Arkadiusz; Chrusciel, Marcin; Miltyk, Wojciech; Doroszko, Milena; Rahman, Nafis; Palka, Jerzy

    2017-01-01

    The effect of impaired intracellular proline availability for proline dehydrogenase/proline oxidase (PRODH/POX)-dependent apoptosis was studied. We generated a constitutively knocked-down PRODH/POX MCF-7 breast cancer cell line (MCF-7shPRODH/POX) as a model to analyze the functional consequences of impaired intracellular proline levels. We have used inhibitor of proline utilization in collagen biosynthesis, 2-metoxyestradiol (MOE), inhibitor of prolidase that generate proline, rapamycin (Rap) and glycyl-proline (GlyPro), substrate for prolidase. Collagen and DNA biosynthesis were evaluated by radiometric assays. Cell viability was determined using Nucleo-Counter NC-3000. The activity of prolidase was determined by colorimetric assay. Expression of proteins was assessed by Western blot and immunofluorescence bioimaging. Concentration of proline was analyzed by liquid chromatography with mass spectrometry. PRODH/POX knockdown decreased DNA and collagen biosynthesis, whereas increased prolidase activity and intracellular proline level in MCF-7shPRODH/POX cells. All studied compounds decreased cell viability in MCF-7 and MCF-7shPRODH/POX cells. DNA biosynthesis was similarly inhibited by Rap and MOE in both cell lines, but GlyPro inhibited the process only in MCF-7shPRODH/POX and MOE+GlyPro only in MCF-7 cells. All the compounds inhibited collagen biosynthesis, increased prolidase activity and cytoplasmic proline level in MCF-7shPRODH/POX cells and contributed to the induction of pro-survival mode only in MCF-7shPRODH/POX cells. In contrast, all studied compounds upregulated expression of pro-apoptotic protein only in MCF-7 cells. PRODH/POX was confirmed as a driver of apoptosis and proved the eligibility of MCF-7shPRODH/POX cell line as a highly effective model to elucidate the different mechanisms underlying proline utilization or generation in PRODH/POX-dependent pro-apoptotic pathways. © 2017 The Author(s). Published by S. Karger AG, Basel.

  14. Population-Level Density Dependence Influences the Origin and Maintenance of Parental Care.

    Directory of Open Access Journals (Sweden)

    Elijah Reyes

    Full Text Available Parental care is a defining feature of animal breeding systems. We now know that both basic life-history characteristics and ecological factors influence the evolution of care. However, relatively little is known about how these factors interact to influence the origin and maintenance of care. Here, we expand upon previous work and explore the relationship between basic life-history characteristics (stage-specific rates of mortality and maturation and the fitness benefits associated with the origin and the maintenance of parental care for two broad ecological scenarios: the scenario in which egg survival is density dependent and the case in which adult survival is density dependent. Our findings suggest that high offspring need is likely critical in driving the origin, but not the maintenance, of parental care regardless of whether density dependence acts on egg or adult survival. In general, parental care is more likely to result in greater fitness benefits when baseline adult mortality is low if 1 egg survival is density dependent or 2 adult mortality is density dependent and mutant density is relatively high. When density dependence acts on egg mortality, low rates of egg maturation and high egg densities are less likely to lead to strong fitness benefits of care. However, when density dependence acts on adult mortality, high levels of egg maturation and increasing adult densities are less likely to maintain care. Juvenile survival has relatively little, if any, effect on the origin and maintenance of egg-only care. More generally, our results suggest that the evolution of parental care will be influenced by an organism's entire life history characteristics, the stage at which density dependence acts, and whether care is originating or being maintained.

  15. N-Acetylcysteine Normalizes Glutamate Levels in Cocaine-Dependent Patients: A Randomized Crossover Magnetic Resonance Spectroscopy Study

    NARCIS (Netherlands)

    Schmaal, Lianne; Veltman, Dick J.; Nederveen, Aart; van den Brink, Wim; Goudriaan, Anna E.

    2012-01-01

    Treatment with N-acetylcysteine (NAC) normalizes glutamate (Glu) homeostasis and prevents relapse in drug-dependent animals. However, the effect of NAC on brain Glu levels in substance-dependent humans has not yet been investigated. Proton magnetic resonance spectroscopy (H-1 MRS) was used to

  16. N-Acetylcysteine Normalizes Glutamate Levels in Cocaine-Dependent Patients: A Randomized Crossover Magnetic Resonance Spectroscopy Study

    NARCIS (Netherlands)

    Schmaal, L.; Veltman, D.J.; Nederveen, A.; van den Brink, W.; Goudriaan, A.E.

    2012-01-01

    Treatment with N-acetylcysteine (NAC) normalizes glutamate (Glu) homeostasis and prevents relapse in drug-dependent animals. However, the effect of NAC on brain Glu levels in substance-dependent humans has not yet been investigated. Proton magnetic resonance spectroscopy (1 H MRS) was used to

  17. Pulsed low-level infrared laser alters mRNA levels from muscle repair genes dependent on power output in Wistar rats

    Science.gov (United States)

    Trajano, L. A. S. N.; Trajano, E. T. L.; Thomé, A. M. C.; Sergio, L. P. S.; Mencalha, A. L.; Stumbo, A. C.; Fonseca, A. S.

    2017-10-01

    Satellite cells are present in skeletal muscle functioning in the repair and regeneration of muscle injury. Activation of these cells depends on the expression of myogenic factor 5 (Myf5), myogenic determination factor 1(MyoD), myogenic regulatory factor 4 (MRF4), myogenin (MyoG), paired box transcription factors 3 (Pax3), and 7 (Pax7). Low-level laser irradiation accelerates the repair of muscle injuries. However, data from the expression of myogenic factors have been controversial. Furthermore, the effects of different laser beam powers on the repair of muscle injuries have been not evaluated. The aim of this study was to evaluate the effects of low-level infrared laser at different powers and in pulsed emission mode on the expression of myogenic regulatory factors and on Pax3 and Pax7 in injured skeletal muscle from Wistar rats. Animals that underwent cryoinjury were divided into three groups: injury, injury laser 25 Mw, and injury laser 75 mW. Low-level infrared laser irradiation (904 nm, 3 J cm-2, 5 kHz) was carried out at 25 and 75 mW. After euthanasia, skeletal muscle samples were withdrawn and the total RNA was extracted for the evaluation of mRNA levels from the MyoD, MyoG, MRF4, Myf5, Pax3, and Pax7 gene. Pax 7 mRNA levels did not alter, but Pax3 mRNA levels increased in the injured and laser-irradiated group at 25 mW. MyoD, MyoG, and MYf5 mRNA levels increased in the injured and laser-irradiated animals at both powers, and MRF4 mRNA levels decreased in the injured and laser-irradiated group at 75 mW. In conclusion, exposure to pulsed low-level infrared laser, by power-dependent effect, could accelerate the muscle repair process altering mRNA levels from paired box transcription factors and myogenic regulatory factors.

  18. Aspects of two-level systems under external time-dependent fields

    Energy Technology Data Exchange (ETDEWEB)

    Bagrov, V.G.; Wreszinski, W.F. [Tomsk State University and Tomsk Institute of High Current Electronics (Russian Federation); Barata, J.C.A.; Gitman D.M. [Universidade de Sao Paulo, Instituto de Fisica (Brazil)]. E-mails: jbarata@fma.if.usp.br; gitman@fma.if.usp.br

    2001-12-14

    The dynamics of two-level systems in time-dependent backgrounds is under consideration. We present some new exact solutions in special backgrounds decaying in time. On the other hand, following ideas of Feynman et al, we discuss in detail the possibility of reducing the quantum dynamics to a classical Hamiltonian system. This, in particular, opens the possibility of directly applying powerful methods of classical mechanics (e.g. KAM methods) to study the quantum system. Following such an approach, we draw conclusions of relevance for 'quantum chaos' when the external background is periodic or quasi-periodic in time. (author)

  19. Reduced-Contrast Approximations for High-Contrast Multiscale Flow Problems

    KAUST Repository

    Chung, Eric T.; Efendiev, Yalchin

    2010-01-01

    In this paper, we study multiscale methods for high-contrast elliptic problems where the media properties change dramatically. The disparity in the media properties (also referred to as high contrast in the paper) introduces an additional scale that needs to be resolved in multiscale simulations. First, we present a construction that uses an integral equation to represent the highcontrast component of the solution. This representation involves solving an integral equation along the interface where the coefficients are discontinuous. The integral representation suggests some multiscale approaches that are discussed in the paper. One of these approaches entails the use of interface functions in addition to multiscale basis functions representing the heterogeneities without high contrast. In this paper, we propose an approximation for the solution of the integral equation using the interface problems in reduced-contrast media. Reduced-contrast media are obtained by lowering the variance of the coefficients. We also propose a similar approach for the solution of the elliptic equation without using an integral representation. This approach is simpler to use in the computations because it does not involve setting up integral equations. The main idea of this approach is to approximate the solution of the high-contrast problem by the solutions of the problems formulated in reduced-contrast media. In this approach, a rapidly converging sequence is proposed where only problems with lower contrast are solved. It was shown that this sequence possesses the convergence rate that is inversely proportional to the reduced contrast. This approximation allows choosing the reduced-contrast problem based on the coarse-mesh size as discussed in this paper. We present a simple application of this approach to homogenization of elliptic equations with high-contrast coefficients. The presented approaches are limited to the cases where there are sharp changes in the contrast (i.e., the high

  20. Relaxivity of blood pool contrast agent depends on the host tissue as suggested by semianalytical simulations

    DEFF Research Database (Denmark)

    Kjølby, Birgitte Fuglsang; Østergaard, Leif; Kiselev, Valerij

    Concentration of magnetic resonance imaging (MRI) contrast agents (CA) cannot be measured directly and is commonly determined indirectly using their relaxation effect. This requires knowledge of the relaxivity of the used CA. Quantitative perfusion studies involve measurement of CA concentration...... studies (3,4) as demonstrated in (5). It was previously found (6) that the perfusion measurements using dynamic susceptibility contrast inherently overestimate cerebral blood flow and volume. In view of the present result, this is attributed to the significant difference in the relaxivity of the CA...

  1. Vitamin D Status in Population of Bukovyna and Subcarpathia Depending on Residence above Sea Level

    Directory of Open Access Journals (Sweden)

    V.V. Povoroznyuk

    2016-04-01

    ding on the residence above sea level. Objective: to determine the level of vitamin D in the blood serum of people, who live in different regions of the Subcarpathia and Bukovyna, depending on the location of the settlement above sea le-vel. Material and methods. In the cross-sectional study, we have examined 353 individuals, aged 18 to 86 years, permanently residing in different parts of the Subcarpathia (Kolomyia, Kosiv, Verhovyna districts and Bukovyna (Vyzhny-tsia district. Results. Only in 28 cases (7.9 %, the content of 25(OHD in the blood serum was in the normal range, and in other cases (92.1 %, there was a deficiency and a lack of vitamin D. The severe form of vitamin D deficiency has been detected in 7 (1.9 % patients. When comparing the performance of 25(OHD in the areas of inspection, it was found that the level of vitamin D in the blood serum was significantly higher in residents of Verkhovyna and Kosiv districts (located higher than 450 meters above sea level as compared with residents of Vyzhnytsia and Kolomyia. Conclusion. The average level of vitamin D in the blood serum of the adult population depends on residence and increases with height above sea level.

  2. The Not-So-Global Blood Oxygen Level-Dependent Signal.

    Science.gov (United States)

    Billings, Jacob; Keilholz, Shella

    2018-04-01

    Global signal regression is a controversial processing step for resting-state functional magnetic resonance imaging, partly because the source of the global blood oxygen level-dependent (BOLD) signal remains unclear. On the one hand, nuisance factors such as motion can readily introduce coherent BOLD changes across the whole brain. On the other hand, the global signal has been linked to neural activity and vigilance levels, suggesting that it contains important neurophysiological information and should not be discarded. Any widespread pattern of coordinated activity is likely to contribute appreciably to the global signal. Such patterns may include large-scale quasiperiodic spatiotemporal patterns, known also to be tied to performance on vigilance tasks. This uncertainty surrounding the separability of the global BOLD signal from concurrent neurological processes motivated an examination of the global BOLD signal's spatial distribution. The results clarify that although the global signal collects information from all tissue classes, a diverse subset of the BOLD signal's independent components contribute the most to the global signal. Further, the timing of each network's contribution to the global signal is not consistent across volunteers, confirming the independence of a constituent process that comprises the global signal.

  3. Contrast-enhanced computed tomography for the diagnosis of fatty liver: prospective study with same-day biopsy used as the reference standard

    International Nuclear Information System (INIS)

    Kim, Dae Yoon; Park, Seong Ho; Lee, Seung Soo; Kim, Hye Jin; Kim, So Yeon; Kim, Min-Young; Lee, Yedaun; Kim, Tae Kyoung; Khalili, Korosh; Bae, Mi Hyun; Lee, Joo Yeon; Lee, Sung-Gyu; Yu, Eun Sil

    2010-01-01

    Purpose: The study purpose was to prospectively determine the accuracy of contrast-enhanced CT in diagnosing fatty liver using same-day biopsy as the reference standard. One hundred seventy-nine potential living liver donors underwent unenhanced and portal-phase contrast-enhanced hepatic CT and subsequent liver biopsy on the same day. Attenuation difference between the liver and the spleen on unenhanced ( pre L-S) and contrast-enhanced ( post L-S) images and blood-subtracted hepatic attenuation on contrast-enhanced images ( post L-B), calculated by [L - 0.3 x (0.75 x P + 0.25 x A) ]/0.7 where L, P and A represent the attenuation of the liver, main portal vein and abdominal aorta, respectively, were obtained. The accuracy of these indices in diagnosing fatty liver according to various threshold levels, 5%-30% histological steatosis in increments of 5%, was compared using ROC analysis. The area under the ROC curve for pre L-S, post L-S and post L-B was 0.663-0.918, 0.712-0.847 and 0.821-0.923, respectively, depending on the threshold levels of hepatic steatosis. The accuracy of pre L-S and post L-S did not differ (P ≥ 0.054), despite a trend towards a lower accuracy with post L-S. post L-B yielded higher accuracy than pre L-S at threshold levels of 5% and 10% (P ≤ 0.002) and similar accuracy to pre L-S at the other threshold levels (P ≥ 0.144). Portal-phase contrast-enhanced CT has a similar, or even greater, accuracy than unenhanced CT in diagnosing fatty liver. (orig.)

  4. Mapping of cerebral metabolic rate of oxygen using dynamic susceptibility contrast and blood oxygen level dependent MR imaging in acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Gersing, Alexandra S.; Schwaiger, Benedikt J. [Technical University Munich, Klinikum rechts der Isar, Department of Neuroradiology, Munich (Germany); University of California, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Ankenbrank, Monika; Toth, Vivien; Bauer, Jan S.; Zimmer, Claus [Technical University Munich, Klinikum rechts der Isar, Department of Neuroradiology, Munich (Germany); Janssen, Insa [Technical University Munich, Department of Neurosurgery, Munich (Germany); Kooijman, Hendrik [Philips Healthcare, Hamburg (Germany); Wunderlich, Silke [Technical University Munich, Department of Neurology, Munich (Germany); Preibisch, Christine [Technical University Munich, Klinikum rechts der Isar, Department of Neuroradiology, Munich (Germany); Technical University Munich, Department of Neurology, Munich (Germany)

    2015-12-15

    MR-derived cerebral metabolic rate of oxygen utilization (CMRO{sub 2}) has been suggested to be analogous to PET-derived CMRO{sub 2} and therefore may be used for detection of viable tissue at risk for infarction. The purpose of this study was to evaluate MR-derived CMRO{sub 2} mapping in acute ischemic stroke in relation to established diffusion- and perfusion-weighted imaging. In 23 patients (mean age 63 ± 18.7 years, 11 women) with imaging findings for acute ischemic stroke, relative oxygen extraction fraction was calculated from quantitative transverse relaxation times (T2, T2*) and relative cerebral blood volume using a quantitative blood oxygenation level dependent (BOLD) approach in order to detect a local increase of deoxyhemoglobin. Relative CMRO{sub 2} (rCMRO{sub 2}) maps were calculated by multiplying relative oxygen extraction fraction (rOEF) by cerebral blood flow, derived from PWI. After co-registration, rCMRO{sub 2} maps were evaluated in comparison with apparent diffusion coefficient (ADC) and time-to-peak (TTP) maps. Mean rCMRO{sub 2} values in areas with diffusion-restriction or TTP/ADC mismatch were compared with rCMRO{sub 2} values in the contralateral tissue. In tissue with diffusion restriction, mean rCMRO{sub 2} values were significantly decreased compared to perfusion-impaired (17.9 [95 % confidence interval 10.3, 25.0] vs. 58.1 [95 % confidence interval 50.1, 70.3]; P < 0.001) and tissue in the contralateral hemisphere (68.2 [95 % confidence interval 61.4, 75.0]; P < 0.001). rCMRO{sub 2} in perfusion-impaired tissue showed no significant change compared to tissue in the contralateral hemisphere (58.1 [95 % confidence interval 50.1, 70.3] vs. 66.7 [95 % confidence interval 53.4, 73.4]; P = 0.34). MR-derived CMRO{sub 2} was decreased within diffusion-restricted tissue and stable within perfusion-impaired tissue, suggesting that this technique may be adequate to reveal different pathophysiological stages in acute stroke. (orig.)

  5. Impact of Many-Body Effects on Landau Levels in Graphene

    Science.gov (United States)

    Sonntag, J.; Reichardt, S.; Wirtz, L.; Beschoten, B.; Katsnelson, M. I.; Libisch, F.; Stampfer, C.

    2018-05-01

    We present magneto-Raman spectroscopy measurements on suspended graphene to investigate the charge carrier density-dependent electron-electron interaction in the presence of Landau levels. Utilizing gate-tunable magnetophonon resonances, we extract the charge carrier density dependence of the Landau level transition energies and the associated effective Fermi velocity vF. In contrast to the logarithmic divergence of vF at zero magnetic field, we find a piecewise linear scaling of vF as a function of the charge carrier density, due to a magnetic-field-induced suppression of the long-range Coulomb interaction. We quantitatively confirm our experimental findings by performing tight-binding calculations on the level of the Hartree-Fock approximation, which also allow us to estimate an excitonic binding energy of ≈6 meV contained in the experimentally extracted Landau level transitions energies.

  6. Response of single bacterial cells to stress gives rise to complex history dependence at the population level

    Science.gov (United States)

    Mathis, Roland; Ackermann, Martin

    2016-01-01

    Most bacteria live in ever-changing environments where periods of stress are common. One fundamental question is whether individual bacterial cells have an increased tolerance to stress if they recently have been exposed to lower levels of the same stressor. To address this question, we worked with the bacterium Caulobacter crescentus and asked whether exposure to a moderate concentration of sodium chloride would affect survival during later exposure to a higher concentration. We found that the effects measured at the population level depended in a surprising and complex way on the time interval between the two exposure events: The effect of the first exposure on survival of the second exposure was positive for some time intervals but negative for others. We hypothesized that the complex pattern of history dependence at the population level was a consequence of the responses of individual cells to sodium chloride that we observed: (i) exposure to moderate concentrations of sodium chloride caused delays in cell division and led to cell-cycle synchronization, and (ii) whether a bacterium would survive subsequent exposure to higher concentrations was dependent on the cell-cycle state. Using computational modeling, we demonstrated that indeed the combination of these two effects could explain the complex patterns of history dependence observed at the population level. Our insight into how the behavior of single cells scales up to processes at the population level provides a perspective on how organisms operate in dynamic environments with fluctuating stress exposure. PMID:26960998

  7. Streak artifacts on Kidney CT: Ionic vs nonionic contrast media

    International Nuclear Information System (INIS)

    Cho, Eun Ok; Kim, Won Hong; Jung, Myung Suk; Kim, Yong Hoon; Hur, Gham

    1993-01-01

    The authors reviewed findings of enhanced abdominal computed tomography (CT) scans to know the difference between a higher dose of conventional ionic contrast media(iothalamate meglumine) and a lower dose of a new, nonionic contrast material(ioversol). One hundred adult patients were divided into two groups. Each group consisted of 50 patients. Iothalamate meglumine and ioversol were intravenously administered in each group. The radio of the male to female in the former was 28:22, and the latter 29:21. We examine the degree of renal streak artifact and measure the Hounsfield number of urine in renal collecting system. There were significant differences of the degree of the streak artifact depending upon the osmolality of contrast media used and that was related with urine CT number(P value<0.005). We authors conclude that nonionic low osmolar contrast media is prone to cause streak artifacts and distortions of renal image than conventional ionic high osmolar contrast media

  8. Local blood-brain barrier penetration following systemic contrast medium administration

    International Nuclear Information System (INIS)

    Utz, R.; Ekholm, S.E.; Isaac, L.; Sands, M.; Fonte, D.

    1988-01-01

    The present study was initiated by a severe complication in a patient with renal dysfunction who developed cortical blindness and weakness of her left extremities 30 hours following renal and abdominal angiography. To evaluate the impact of prolonged high serum concentrations of contrast medium (CM) this clinical situation was simulated in a laboratory model using sheep with elevated serum levels of contrast medium maintained for 48 hours. The experimental data did not support the theory that the prolonged exposure to high circulating levels of contrast medium (4 ml/kg body weight of meglumine diatrizoate 60%) is sufficient alone to cause penetration of the blood-brain barrier. (orig.)

  9. Effects of the level of early productivity on the lifespan of ewes in contrasting flock environments.

    Science.gov (United States)

    Douhard, F; Jopson, N B; Friggens, N C; Amer, P R

    2016-12-01

    Selection for high levels of prolificacy has allowed substantial improvements in the production efficiency of New Zealand (NZ) sheep farms, but the consequences on ewe lifetime performance are mostly unknown. In this study, the relationship between the level of prolificacy early in ewes' productive lives and their probability to survive later (i.e. stayability) was evaluated in two contrasting NZ flock environments. Records were obtained from 6605 ewes from four ram breeder flocks representing either a moderate (n=2) or a highly variable (n=2) nutritional environment. All ewes lambed for the first time at 2 years of age and were mated the following year. The number of lambs born during the first 2 years of productive life (NLB2-3) was used as a measure of early prolificacy. Effects of NLB2-3 on stayability to 4, 5, 6, 7 and 8 years old were analysed using logistic regression. Curvilinear effects (logit-transformed) were detected (Pewe stayability was reduced when the proportion of the litter that survived from birth to weaning (i.e. ewe rearing ability) was submaximal during the early productive life. High prolific ewes had a low rearing ability whatever the environment whereas the rearing ability of lowly prolific ewes was apparently more sensitive to the nutritional environment. The poor maternal performance of ewes with low levels of NLB2-3 led to a premature culling by breeders whereas the high early reproductive effort associated with high levels of NLB2-3 seemed to be at the cost of ewes' survival, even in the moderate flock environment. In conclusion, the flock environment influenced the level of early prolificacy beyond which ewe longevity was reduced. It is suggested that further selection for high and early prolificacy in NZ flocks is likely to impair ewes' lifetime productivity.

  10. Mycorrhizal dependency of mangaba tree under increasing phosphorus levels Dependência micorrízica de mangabeira em doses crescentes de fósforo

    Directory of Open Access Journals (Sweden)

    Júlio Alves Cardoso Filho

    2008-07-01

    Full Text Available The objective of this study was to evaluate the mycorrhizal dependency of mangaba tree (Hancornia speciosa plantlets, under increasing levels of phosphorus fertilization. The experimental design was completely randomized in a 4×5 factorial arrangement with three mycorrhizal fungi inocula - Gigaspora margarita, Glomus etunicatum, or a pool of native mycorrhizal fungi (Acaulospora longula, Glomus clarum, Gigaspora albida, Paraglomus sp. -, and a nonmycorrhizal control, in combination with five levels of phosphorus applied to the substrate: 0, 25, 50, 75, and 100 mg kg-1. After 180 days of growth, plantlets with inoculation of native mycorrhizal pool produced more shoot and root dry biomass and had higher shoot phosphorus content and accumulation. The noninoculated control showed the lowest values, independently of the phosphorus level. The highest relative mycorrhizal dependency occurred with the inoculation of native mycorrhizal fungi. Plants with mycorrhizal fungi did not respond to phosphorus addition above 50 mg kg-1. Mangaba tree is highly dependent on mycorrhiza, but the degree of dependency varies according to phosphorus levels and fungal inocula. In general, mangaba tree is more responsive to mycorrhizal fungi inoculation than to phosphorus addition.O objetivo deste trabalho foi avaliar a dependência micorrízica de mudas de mangaba (Hancornia speciosa, em doses crescentes de fósforo. O delineamento experimental foi inteiramente casualizado, em arranjo fatorial 4´5 com três inóculos de fungos micorrízicos - Gigaspora margarita, Glomus etunicatum, ou uma mistura de espécies de fungos micorrízicos nativos (Acaulospora longula, Glomus clarum, Gigaspora albida e Paraglomus sp. -, e um controle não micorrízico, combinados a cinco doses de fósforo no substrato: 0, 25, 50, 75 e 100 mg kg-1. Após 180 dias, as mudas com inoculação dos fungos micorrízicos nativos produziram mais biomassa seca de parte aérea e raízes e apresentaram

  11. Value of the Gd-DTPA contrast enhanced MR in patients with failed back surgery syndrome

    International Nuclear Information System (INIS)

    Paprzycki, W.; Gradzki, J.; Sosnowski, P.; Stajgis, M.

    1994-01-01

    Gd-DTPA contrast - enhanced MR enables differentiation between postoperative scar and recurrent prolapse of nucleus pulposus (RPNP). Pre- and post-contrast MR studies in 40 patients with failed back surgery syndrome, previously treated surgically on 54 intervertebral levels, were evaluated. Presence of RPNP was confirmed on 4, postoperative scars on 35 and both condition on 15 invertebral levels. Correct interpretation of pathologic changes on 15 invertebral levels (28%) was only possible after contrast enhancement. Contrast enhancement of scar excluded the diagnosis of coexistence of RPNP and scar, based on pre-contrast MR studies. MR with Gd-DTPA contrast enhancement is the best diagnostic method in patients with failed back surgery syndrome (author)

  12. Improving education for the management of contrast reactions: an online didactic model.

    Science.gov (United States)

    Niell, Bethany L; Vartanians, Vartan M; Halpern, Elkan P

    2014-02-01

    Radiologists could improve their knowledge of contrast reaction management. The aim of this study was to evaluate to what degree the implementation of a didactic module resulted in improved technologist, nurse, and physician knowledge and comfort levels regarding the appropriate management of adverse reactions to contrast media. After institutional review board approval was obtained, nurses, technologists, and physicians involved in contrast administration were required to complete the educational module. Premodule and postmodule assessments were designed online. Each assessment included knowledge-based questions regarding the appropriate management of different types of contrast reactions, as well as questions regarding each respondent's comfort level with the treatment of various types of adverse contrast reactions. Comfort level was measured using a 6-point, Likert-type scale. Premodule and postmodule assessment scores were compared using McNemar's test. After module completion, physicians demonstrated a statistically significant improvement in knowledge regarding the proper administration route, concentration, and dose of intramuscular epinephrine. Physicians demonstrated significantly increased comfort with the administration of intramuscular epinephrine to adult and pediatric patients after module completion (P Didactic instruction in contrast reaction management results in improved knowledge and comfort levels for physicians, nurses, and technologists. However, a significant percentage of personnel still reported feeling uncomfortable treating an adverse contrast reaction after module completion, suggesting that didactic instruction alone may be inadequate. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  13. Intravenous digital subtraction angiography contrast media time-concentration curves

    International Nuclear Information System (INIS)

    Burbank, F.H.; Brody, W.R.

    1985-01-01

    At any specified radiation dose and system signal-to-noise ratio, temporal (masked-mode) intravenous digital subtraction angiography (IV-DSA) image quality is dependent upon the shape of the arterial time-concentration curve produced by the intravenous injection of iodinated contrast media. If contrast media appears in the arterial circulation as a compact bolus and reaches a high peak, images containing low or no iodine (the mask image or images) and high iodine concentration (the enhanced image or images) can be obtained close together in time, maximizing contrast media enhancement and minimizing the potential for spatial movement (misregistration). However, if the contrast media bolus is broad, rising slowly to a low concentration peak, sufficient time may pass for movement to occur and the opacification difference between the mask image and the enhanced image may be too small to visualize vessels of interest. Consequently, knowledge of the rules which govern the formation of time-concentration curves is central to IV-DSA

  14. Comparative evaluation of positive contrast and double contrast gastrography in dogs

    International Nuclear Information System (INIS)

    Dileepkumar, K.M.; Rajankutty, K.; Sarada, Amma T.; Devanand, C.B.; Vijayan, N.

    2012-01-01

    A contrast radiography of stomach with oral barium sulphate suspension 25% (5 mL/kg b.wt positive contrast) and double contrast with oral barium sulphate 25% (3 mL/kg b.wt) followed by air (2 to 10 mL/kg b.wt, negative contrast) was done on six dogs to study the affections of stomach. Contrast radiography using barium sulphate alone was found satisfactory to identify most of the lesions of the stomach. Double contrast radiography using barium sulphate and air, required sedation to control the animals for proper administration. For the diagnosis of mucosal lesions, double contrast radiography was better than barium sulphate alone. Key words: Barium, Contrast radiography, Dog, Double contrast, Stomach

  15. In Vitro Validation of an Artefact Suppression Algorithm in X-Ray Phase-Contrast Computed Tomography.

    Science.gov (United States)

    Sunaguchi, Naoki; Yuasa, Tetsuya; Hirano, Shin-Ichi; Gupta, Rajiv; Ando, Masami

    2015-01-01

    X-ray phase-contrast tomography can significantly increase the contrast-resolution of conventional attenuation-contrast imaging, especially for soft-tissue structures that have very similar attenuation. Just as in attenuation-based tomography, phase contrast tomography requires a linear dependence of aggregate beam direction on the incremental direction alteration caused by individual voxels along the path of the X-ray beam. Dense objects such as calcifications in biological specimens violate this condition. There are extensive beam deflection artefacts in the vicinity of such structures because they result in large distortion of wave front due to the large difference of refractive index; for such large changes in beam direction, the transmittance of the silicon analyzer crystal saturates and is no longer linearly dependent on the angle of refraction. This paper describes a method by which these effects can be overcome and excellent soft-tissue contrast of phase tomography can be preserved in the vicinity of such artefact-producing structures.

  16. Theoretical model for optical oximetry at the capillary level: exploring hemoglobin oxygen saturation through backscattering of single red blood cells

    Science.gov (United States)

    Liu, Rongrong; Spicer, Graham; Chen, Siyu; Zhang, Hao F.; Yi, Ji; Backman, Vadim

    2017-02-01

    Oxygen saturation (sO2) of red blood cells (RBCs) in capillaries can indirectly assess local tissue oxygenation and metabolic function. For example, the altered retinal oxygenation in diabetic retinopathy and local hypoxia during tumor development in cancer are reflected by abnormal sO2 of local capillary networks. However, it is far from clear whether accurate label-free optical oximetry (i.e., measuring hemoglobin sO2) is feasible from dispersed RBCs at the single capillary level. The sO2-dependent hemoglobin absorption contrast present in optical scattering signal is complicated by geometry-dependent scattering from RBCs. We present a numerical study of backscattering spectra from single RBCs based on the first-order Born approximation, considering practical factors: RBC orientations, size variation, and deformations. We show that the oscillatory spectral behavior of RBC geometries is smoothed by variations in cell size and orientation, resulting in clear sO2-dependent spectral contrast. In addition, this spectral contrast persists with different mean cellular hemoglobin content and different deformations of RBCs. This study shows for the first time the feasibility of, and provides a theoretical model for, label-free optical oximetry at the single capillary level using backscattering-based imaging modalities, challenging the popular view that such measurements are impossible at the single capillary level.

  17. Analysis of Two-Level Support Systems with Time-Dependent Overflow - A Banking Application

    DEFF Research Database (Denmark)

    Barth, Wolfgang; Manitz, Michael; Stolletz, Raik

    2010-01-01

    In this paper, we analyze the performance of call centers of financial service providers with two levels of support and a time-dependent overflow mechanism. Waiting calls from the front-office queue flow over to the back office if a waiting-time limit is reached and at least one back-office agent...

  18. Contrast Enhanced Spectral Mammography: A Review.

    Science.gov (United States)

    Patel, Bhavika K; Lobbes, M B I; Lewin, John

    2018-02-01

    Contrast-enhanced spectral mammography (CESM) provides low-energy 2D mammographic images comparable to standard digital mammography and a post-contrast recombined image to assess tumor neovascularity similar to magnetic resonance imaging (MRI). The utilization of CESM in the United States is currently low but could increase rapidly given many potential indications for clinical use. This article discusses historical background and literature review of indications and diagnostic accuracy of CESM to date. CESM is a growing technique for breast cancer detection and diagnosis that has levels of sensitivity and specificity on par with contrast-enhanced breast MRI. Because of its similar performance and ease of implementation, CESM is being adopted for multiple indications previously reserved for MRI, such as problem-solving, disease extent in newly diagnosed patients, and evaluating the treatment response of neoadjuvant chemotherapy. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Element-specific spectral imaging of multiple contrast agents: a phantom study

    Science.gov (United States)

    Panta, R. K.; Bell, S. T.; Healy, J. L.; Aamir, R.; Bateman, C. J.; Moghiseh, M.; Butler, A. P. H.; Anderson, N. G.

    2018-02-01

    This work demonstrates the feasibility of simultaneous discrimination of multiple contrast agents based on their element-specific and energy-dependent X-ray attenuation properties using a pre-clinical photon-counting spectral CT. We used a photon-counting based pre-clinical spectral CT scanner with four energy thresholds to measure the X-ray attenuation properties of various concentrations of iodine (9, 18 and 36 mg/ml), gadolinium (2, 4 and 8 mg/ml) and gold (2, 4 and 8 mg/ml) based contrast agents, calcium chloride (140 and 280 mg/ml) and water. We evaluated the spectral imaging performances of different energy threshold schemes between 25 to 82 keV at 118 kVp, based on K-factor and signal-to-noise ratio and ranked them. K-factor was defined as the X-ray attenuation in the K-edge containing energy range divided by the X-ray attenuation in the preceding energy range, expressed as a percentage. We evaluated the effectiveness of the optimised energy selection to discriminate all three contrast agents in a phantom of 33 mm diameter. A photon-counting spectral CT using four energy thresholds of 27, 33, 49 and 81 keV at 118 kVp simultaneously discriminated three contrast agents based on iodine, gadolinium and gold at various concentrations using their K-edge and energy-dependent X-ray attenuation features in a single scan. A ranking method to evaluate spectral imaging performance enabled energy thresholds to be optimised to discriminate iodine, gadolinium and gold contrast agents in a single spectral CT scan. Simultaneous discrimination of multiple contrast agents in a single scan is likely to open up new possibilities of improving the accuracy of disease diagnosis by simultaneously imaging multiple bio-markers each labelled with a nano-contrast agent.

  20. Safety of contrast media. Focus on contrast-induced nephropathy (CIN)

    International Nuclear Information System (INIS)

    Kuwatsuru, Ryohei

    2011-01-01

    Despite advances in imaging diagnosis, contrast media still play an important role in diagnosing the existence of the disease, demonstrating the extent of disease, and determining the perfusion of the disease, which is important to make a differential diagnosis. However, the administration of contrast media may cause contrast-induced nephropathy (CIN), especially in patients with renal impairment. It is estimated that 20-30% of patients with renal impairment who received contrast media develop CIN. Though the precise cause of CIN currently remains unknown, almost all injected contrast media are excreted through the kidney and the effects of contrast media on the kidney are easily understood. As CIN is the most common cause of death due to complications after receiving contrast media, prevention of CIN is important. There are several known risk factors for CIN. Patients with renal impairment, diabetes mellitus, and dehydration are at high risk for CIN. Furthermore, a high osmolar contrast media, excessive amount of contrast media, and ionic contrast media are also risk factors for CIN. CIN can be prevented in several ways. Certain drugs seem to be useful to prevent CIN, while others are harmful. Hydration is useful to prevent CIN, although there is no widely acceptable hydration method to prevent CIN. Both sodium bicarbonate and N-acetylcysteine are promising candidates for prevention of CIN. There are few reports to study CIN after intravenous administration, although reports of CIN after percutaneous cardiac intervention (PCI) and angiography are well recognized. In clinical situations, intravenous administration of contrast media is common. Therefore, a study of CIN after intravenous administration of contrast media should be performed. (author)

  1. Multi-regional investigation of the relationship between functional MRI blood oxygenation level dependent (BOLD activation and GABA concentration.

    Directory of Open Access Journals (Sweden)

    Ashley D Harris

    Full Text Available Several recent studies have reported an inter-individual correlation between regional GABA concentration, as measured by MRS, and the amplitude of the functional blood oxygenation level dependent (BOLD response in the same region. In this study, we set out to investigate whether this coupling generalizes across cortex. In 18 healthy participants, we performed edited MRS measurements of GABA and BOLD-fMRI experiments using regionally related activation paradigms. Regions and tasks were the: occipital cortex with a visual grating stimulus; auditory cortex with a white noise stimulus; sensorimotor cortex with a finger-tapping task; frontal eye field with a saccade task; and dorsolateral prefrontal cortex with a working memory task. In contrast to the prior literature, no correlation between GABA concentration and BOLD activation was detected in any region. The origin of this discrepancy is not clear. Subtle differences in study design or insufficient power may cause differing results; these and other potential reasons for the discrepant results are discussed. This negative result, although it should be interpreted with caution, has a larger sample size than prior positive results, and suggests that the relationship between GABA and the BOLD response may be more complex than previously thought.

  2. Prostate-specific membrane antigen targeted protein contrast agents for molecular imaging of prostate cancer by MRI

    Science.gov (United States)

    Pu, Fan; Salarian, Mani; Xue, Shenghui; Qiao, Jingjuan; Feng, Jie; Tan, Shanshan; Patel, Anvi; Li, Xin; Mamouni, Kenza; Hekmatyar, Khan; Zou, Juan; Wu, Daqing; Yang, Jenny J.

    2016-06-01

    Prostate-specific membrane antigen (PSMA) is one of the most specific cell surface markers for prostate cancer diagnosis and targeted treatment. However, achieving molecular imaging using non-invasive MRI with high resolution has yet to be achieved due to the lack of contrast agents with significantly improved relaxivity for sensitivity, targeting capabilities and metal selectivity. We have previously reported our creation of a novel class of protein Gd3+ contrast agents, ProCA32, which displayed significantly improved relaxivity while exhibiting strong Gd3+ binding selectivity over physiological metal ions. In this study, we report our effort in further developing biomarker-targeted protein MRI contrast agents for molecular imaging of PSMA. Among three PSMA targeted contrast agents engineered with addition of different molecular recognition sequences, ProCA32.PSMA exhibits a binding affinity of 1.1 +/- 0.1 μM for PSMA while the metal binding affinity is maintained at 0.9 +/- 0.1 × 10-22 M. In addition, ProCA32.PSMA exhibits r1 of 27.6 mM-1 s-1 and r2 of 37.9 mM-1 s-1 per Gd (55.2 and 75.8 mM-1 s-1 per molecule r1 and r2, respectively) at 1.4 T. At 7 T, ProCA32.PSMA also has r2 of 94.0 mM-1 s-1 per Gd (188.0 mM-1 s-1 per molecule) and r1 of 18.6 mM-1 s-1 per Gd (37.2 mM-1 s-1 per molecule). This contrast capability enables the first MRI enhancement dependent on PSMA expression levels in tumor bearing mice using both T1 and T2-weighted MRI at 7 T. Further development of these PSMA-targeted contrast agents are expected to be used for the precision imaging of prostate cancer at an early stage and to monitor disease progression and staging, as well as determine the effect of therapeutic treatment by non-invasive evaluation of the PSMA level using MRI.Prostate-specific membrane antigen (PSMA) is one of the most specific cell surface markers for prostate cancer diagnosis and targeted treatment. However, achieving molecular imaging using non-invasive MRI with high

  3. Contrast-enhanced peripheral MRA. Technique and contrast agents

    International Nuclear Information System (INIS)

    Nielsen, Yousef W.; Thomsen, Henrik S.

    2012-01-01

    In the last decade contrast-enhanced magnetic resonance angiography (CE-MRA) has gained wide acceptance as a valuable tool in the diagnostic work-up of patients with peripheral arterial disease. This review presents current concepts in peripheral CE-MRA with emphasis on MRI technique and contrast agents. Peripheral CE-MRA is defined as an MR angiogram of the arteries from the aortic bifurcation to the feet. Advantages of CE-MRA include minimal invasiveness and lack of ionizing radiation. The basic technique employed for peripheral CE-MRA is the bolus-chase method. With this method a paramagnetic MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic field strength of the MRI system, receiver coil configuration, use of parallel imaging, contrast bolus timing technique, and k-space filling strategies. Furthermore, it is possible to optimize peripheral CE-MRA using venous compression techniques, hybrid scan protocols, time-resolved imaging, and steady-state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged intravascular stay, due to macromolecular structure or protein binding. These agents can be used for first-pass, as well as steady-state MRA. Some Gd-based contrast agents with low thermodynamic stability have been linked to development of nephrogenic systemic fibrosis in patients with severe renal insufficiency. Using optimized technique and a stable MRI contrast agent, peripheral CE-MRA is a safe procedure with diagnostic accuracy close to that of conventional catheter X

  4. Effect of contrast media iodine concentration on bolus tracking

    International Nuclear Information System (INIS)

    Ishihara, Toshihiro; Hayashi, Takayuki; Nakaya, Yoshihiro; Naoi, Kuniji; Ikeno, Naoya; Kobayashi, Tatsushi; Satake, Mitsuo

    2006-01-01

    Computer-assisted bolus tracking has been confirmed to be a useful technique in computed tomography (CT) imaging and allows images to be captured with automated timing. The inflow of the contrast medium is monitored, and when the contrast medium reaches a predetermined level, CT image capture starts automatically. However, it has been shown that the preset threshold value of contrast medium is affected by its iodine concentration, which causes variations in image capture times. Greater speed in current multislice CT imaging requires that medical technicians pay more attention to setting the timing of image capture during venous examinations by taking into account the iodine concentration in contrast media. (author)

  5. Computed radiography utilizing laser-stimulated luminescence: detectability of simulated low-contrast radiographic objects.

    Science.gov (United States)

    Higashida, Y; Moribe, N; Hirata, Y; Morita, K; Doudanuki, S; Sonoda, Y; Katsuda, N; Hiai, Y; Misumi, W; Matsumoto, M

    1988-01-01

    Threshold contrasts of low-contrast objects with computed radiography (CR) images were compared with those of blue and green emitting screen-film systems by employing the 18-alternative forced choice (18-AFC) procedure. The dependence of the threshold contrast on the incident X-ray exposure and also the object size was studied. The results indicated that the threshold contrasts of CR system were comparable to those of blue and green screen-film systems and decreased with increasing object size, and increased with decreasing incident X-ray exposure. The increase in threshold contrasts was small when the relative incident exposure decreased from 1 to 1/4, and was large when incident exposure was decreased further.

  6. Self-perceived level of competitiveness, tension, and dependency and lifestyles in the 'Seguimiento Universidad de Navarra' cohort study.

    Science.gov (United States)

    Unzueta, C R; Lahortiga-Ramos, F; Santiago, S; Zazpe, I; Molero, P; Sánchez-Villegas, A; Martínez-González, M A

    2018-04-01

    The objective of this study is to assess the differences in lifestyles according to levels of self-perceived competitiveness, psychological tension, and dependency in a Mediterranean cohort of university graduates. Levels of personality traits, food consumption, nutrient intake, eating attitudes, physical activity, sedentary lifestyle, and alcohol and tobacco consumption were assessed through a questionnaire administered at baseline. This was a cross-sectional study in the context of the Seguimiento Universidad de Navarra cohort. Participants are 15,346 Spanish adults. Participants with a high level of self-perceived competitiveness consumed more vegetables and fish but less refined grains; they had higher protein intake and healthier eating attitudes. They were more physically active and less likely to be smokers. Participants with a high level of tension or dependency were less physically active, and participants more dependent also had poorer adherence to the Mediterranean diet. Self-perceived personality traits, especially the trait of competitiveness, are likely to be associated with healthier dietary patterns, better nutrient profile, better eating attitudes, physical activity, and less exposure to smoking. The use of short questions about self-perceived levels of competitiveness, psychological tension, and dependency can contribute to add additional information when assessing lifestyles and diet in adults. Copyright © 2018 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  7. Models of consumer behavior of households depending on the income level

    Directory of Open Access Journals (Sweden)

    Melnikova A.S.

    2016-11-01

    Full Text Available the consumer behavior of households is defined by a complex of internal and external factors: income of the population, motives and incentives of behavior, behavioral norms and personal preferences. As the example of structure analysis of the income and expenses of households of Sverdlovsk region during research models of consumer behavior of households are allocated, characteristics and structure of the population depending on their welfare are allocated. Author's approach allows forecasting of the consumer market, proceeding from the socio-economic factors forming the level of the population income in the region.

  8. Contrast-enhanced computed tomography for the diagnosis of fatty liver: prospective study with same-day biopsy used as the reference standard

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Yoon; Park, Seong Ho; Lee, Seung Soo; Kim, Hye Jin; Kim, So Yeon; Kim, Min-Young; Lee, Yedaun [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea); Kim, Tae Kyoung; Khalili, Korosh [University of Toronto, Department of Medical Imaging, University Health Network, Toronto, ON (Canada); Bae, Mi Hyun; Lee, Joo Yeon [University of Ulsan College of Medicine, Seoul (Korea); Lee, Sung-Gyu [University of Ulsan College of Medicine, Asan Medical Center, Division of Hepatobiliary Surgery and Liver Transplantation, Department of Surgery, Seoul (Korea); Yu, Eun Sil [University of Ulsan College of Medicine, Asan Medical Center, Department of Diagnostic Pathology, Seoul (Korea)

    2010-02-15

    Purpose: The study purpose was to prospectively determine the accuracy of contrast-enhanced CT in diagnosing fatty liver using same-day biopsy as the reference standard. One hundred seventy-nine potential living liver donors underwent unenhanced and portal-phase contrast-enhanced hepatic CT and subsequent liver biopsy on the same day. Attenuation difference between the liver and the spleen on unenhanced ({sub pre} L-S) and contrast-enhanced ({sub post} L-S) images and blood-subtracted hepatic attenuation on contrast-enhanced images ({sub post} L-B), calculated by [L - 0.3 x (0.75 x P + 0.25 x A) ]/0.7 where L, P and A represent the attenuation of the liver, main portal vein and abdominal aorta, respectively, were obtained. The accuracy of these indices in diagnosing fatty liver according to various threshold levels, 5%-30% histological steatosis in increments of 5%, was compared using ROC analysis. The area under the ROC curve for{sub pre} L-S,{sub post} L-S and{sub post} L-B was 0.663-0.918, 0.712-0.847 and 0.821-0.923, respectively, depending on the threshold levels of hepatic steatosis. The accuracy of{sub pre} L-S and{sub post} L-S did not differ (P {>=} 0.054), despite a trend towards a lower accuracy with{sub post} L-S.{sub post} L-B yielded higher accuracy than{sub pre} L-S at threshold levels of 5% and 10% (P {<=} 0.002) and similar accuracy to{sub pre} L-S at the other threshold levels (P {>=} 0.144). Portal-phase contrast-enhanced CT has a similar, or even greater, accuracy than unenhanced CT in diagnosing fatty liver. (orig.)

  9. Quantitative contrast-enhanced optical coherence tomography

    Energy Technology Data Exchange (ETDEWEB)

    Winetraub, Yonatan; SoRelle, Elliott D. [Molecular Imaging Program at Stanford, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Bio-X Program, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Biophysics Program, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Department of Structural Biology, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Liba, Orly [Molecular Imaging Program at Stanford, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Bio-X Program, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Department of Structural Biology, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Department of Electrical Engineering, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Zerda, Adam de la [Molecular Imaging Program at Stanford, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Bio-X Program, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Biophysics Program, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Department of Structural Biology, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States); Department of Electrical Engineering, Stanford University, 299 Campus Drive, Stanford, California 94305 (United States)

    2016-01-11

    We have developed a model to accurately quantify the signals produced by exogenous scattering agents used for contrast-enhanced Optical Coherence Tomography (OCT). This model predicts distinct concentration-dependent signal trends that arise from the underlying physics of OCT detection. Accordingly, we show that real scattering particles can be described as simplified ideal scatterers with modified scattering intensity and concentration. The relation between OCT signal and particle concentration is approximately linear at concentrations lower than 0.8 particle per imaging voxel. However, at higher concentrations, interference effects cause signal to increase with a square root dependence on the number of particles within a voxel. Finally, high particle concentrations cause enough light attenuation to saturate the detected signal. Predictions were validated by comparison with measured OCT signals from gold nanorods (GNRs) prepared in water at concentrations ranging over five orders of magnitude (50 fM to 5 nM). In addition, we validated that our model accurately predicts the signal responses of GNRs in highly heterogeneous scattering environments including whole blood and living animals. By enabling particle quantification, this work provides a valuable tool for current and future contrast-enhanced in vivo OCT studies. More generally, the model described herein may inform the interpretation of detected signals in modalities that rely on coherence-based detection or are susceptible to interference effects.

  10. On the influence of the electron dose rate on the HRTEM image contrast

    Energy Technology Data Exchange (ETDEWEB)

    Barthel, Juri, E-mail: ju.barthel@fz-juelich.de [RWTH Aachen University, Ahornstraße 55, 52074 Aachen (Germany); Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons, Forschungszentrum Jülich GmbH, 52425 Jülich (Germany); Lentzen, Markus; Thust, Andreas [Peter Grünberg Institute, Forschungszentrum Jülich GmbH, 52425 Jülich (Germany); Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons, Forschungszentrum Jülich GmbH, 52425 Jülich (Germany)

    2017-05-15

    We investigate a possible dependence between the applied electron dose-rate and the magnitude of the resulting image contrast in HRTEM of inorganic crystalline objects. The present study is focussed on the question whether electron irradiation can induce excessively strong atom vibrations or displacements, which in turn could significantly reduce the resulting image contrast. For this purpose, high-resolution images of MgO, Ge, and Au samples were acquired with varying dose rates using a C{sub S}-corrected FEI Titan 80–300 microscope operated at 300 kV accelerating voltage. This investigation shows that the magnitude of the signal contrast is independent from the dose rates occurring in conventional HRTEM experiments and that excessively strong vibrations or displacements of bulk atoms are not induced by the applied electron irradiation. - Highlights: • No dependence between electron dose rate and HRTEM image contrast is found. • This finding is in full accordance with established solid-state physics theory. • Object-related causes for the previous Stobbs-factor phenomenon are ruled out.

  11. On the Perpetual American Put Options for Level Dependent Volatility Models with Jumps

    OpenAIRE

    Bayraktar, Erhan

    2007-01-01

    We prove that the perpetual American put option price of level dependent volatility model with compound Poisson jumps is convex and is the classical solution of its associated quasi-variational inequality, that it is $C^2$ except at the stopping boundary and that it is $C^1$ everywhere (i.e. the smooth pasting condition always holds).

  12. Zolpidem reduces the blood oxygen level-dependent signal during visual system stimulation

    OpenAIRE

    Licata, Stephanie C.; Lowen, Steven B.; Trksak, George H.; MacLean, Robert R.; Lukas, Scott E.

    2011-01-01

    Zolpidem is a short-acting imidazopyridine hypnotic that binds at the benzodiazepine binding site on specific GABAA receptors to enhance fast inhibitory neurotransmission. The behavioral and receptor pharmacology of zolpidem has been studied extensively, but little is known about its neuronal substrates in vivo. In the present within-subject, double-blind, and placebo-controlled study, blood oxygen level-dependent functional magnetic resonance imaging (BOLD fMRI) at 3 Tesla was used to assess...

  13. Laser Speckle Contrast Imaging: theory, instrumentation and applications.

    Science.gov (United States)

    Senarathna, Janaka; Rege, Abhishek; Li, Nan; Thakor, Nitish V

    2013-01-01

    Laser Speckle Contrast Imaging (LSCI) is a wide field of view, non scanning optical technique for observing blood flow. Speckles are produced when coherent light scattered back from biological tissue is diffracted through the limiting aperture of focusing optics. Mobile scatterers cause the speckle pattern to blur; a model can be constructed by inversely relating the degree of blur, termed speckle contrast to the scatterer speed. In tissue, red blood cells are the main source of moving scatterers. Therefore, blood flow acts as a virtual contrast agent, outlining blood vessels. The spatial resolution (~10 μm) and temporal resolution (10 ms to 10 s) of LSCI can be tailored to the application. Restricted by the penetration depth of light, LSCI can only visualize superficial blood flow. Additionally, due to its non scanning nature, LSCI is unable to provide depth resolved images. The simple setup and non-dependence on exogenous contrast agents have made LSCI a popular tool for studying vascular structure and blood flow dynamics. We discuss the theory and practice of LSCI and critically analyze its merit in major areas of application such as retinal imaging, imaging of skin perfusion as well as imaging of neurophysiology.

  14. Influence of time dependent effects on the disposal environments of low and intermediate level radioactive wastes

    International Nuclear Information System (INIS)

    1984-12-01

    Reviews are presented firstly of potential events and processes which may affect the evolution of the disposal environments of low and intermediate level radioactive wastes in Britain and secondly of previous studies carried out worldwide in the field of time dependent effects. From the latter review available methodologies for incorporating time dependence into radiological assessments are identified. Finally, proposals are presented for the design and development of a time dependent effects model, based on the existing far field state model (FFSM) developed for ONWI in USA. (author)

  15. Administration of biliary contrast media in computed tomography

    International Nuclear Information System (INIS)

    Huebener, K.-H.; Treugut, H.

    1981-01-01

    Biliary contrast media have 2 main uses in computed tomography (CT) of the liver and bile ducts: 1. Labelling of extrahepatic bile ducts in order to aid in the identification of the common bile ducts and the papilla of Vater, particularly in cases of complex, mostly postoperative situs. 2. Differentiation between normal and abnormal liver tissue in cases of focal nodular hyperplasia with proliferation of tumorous bile ducts. The applicability of biliary contrast media is rather limited as far as the improvement of spatial resolution by an increase of contrast is concerned, because the attainable enhancement today remains small. The possibility of interpretation of the liver function is likewise insufficient, because the standard deviation of the time-dependent enhancement is too great in the normal collective in order to register deviations reliably. In cases of liver cirrhosis, a rise of density of at least 40-60 Hounsfield Units (HU) would be desirable. (Auth.)

  16. Quantitative Study of Longitudinal Relaxation (T 1) Contrast Mechanisms in Brain MRI

    Science.gov (United States)

    Jiang, Xu

    Longitudinal relaxation (T1) contrast in MRI is important for studying brain morphology and is widely used in clinical applications. Although MRI only detects signals from water hydrogen ( 1H) protons (WPs), T1 contrast is known to be influenced by other species of 1H protons, including those in macromolecules (MPs), such as lipids and proteins, through magnetization transfer (MT) between WPs and MPs. This complicates the use and quantification of T1 contrast for studying the underlying tissue composition and the physiology of the brain. MT contributes to T1 contrast to an extent that is generally dependent on MT kinetics, as well as the concentration and NMR spectral properties of MPs. However, the MP spectral properties and MT kinetics are both difficult to measure directly, as the signal from MPs is generally invisible to MRI. Therefore, to investigate MT kinetics and further quantify T1 contrast, we first developed a reliable way to indirectly measure the MP fraction and their exchange rate with WPs, with minimal dependence on the spectral properties of MPs. For this purpose, we used brief, highpower radiofrequency (RF) NMR excitation pulses to almost completely saturate the magnetization of MPs. Based on this, both MT kinetics and the contribution of MPs to T1 contrast through MT were studied. The thus obtained knowledge allowed us to subsequently infer the spectral properties of MPs by applying low-power, frequencyselective off-resonance RF pulses and measuring the offset-frequency dependent effect of MPs on the WP MRI signal. A two-pool exchange model was used in both cases to account for direct effects of the RF pulse on WP magnetization. Consistent with earlier works using MRI at low-field and post-mortem analysis of brain tissue, our novel measurement approach found that MPs constitute an up to 27% fraction of the total 1H protons in human brain white matter, and their spectrum follows a super-Lorentzian line with a T2 of 9.6+/-0.6 mus and a resonance

  17. High-Fidelity Contrast Reaction Simulation Training: Performance Comparison of Faculty, Fellows, and Residents.

    Science.gov (United States)

    Pfeifer, Kyle; Staib, Lawrence; Arango, Jennifer; Kirsch, John; Arici, Mel; Kappus, Liana; Pahade, Jay

    2016-01-01

    Reactions to contrast material are uncommon in diagnostic radiology, and vary in clinical presentation from urticaria to life-threatening anaphylaxis. Prior studies have demonstrated a high error rate in contrast reaction management, with smaller studies using simulation demonstrating variable data on effectiveness. We sought to assess the effectiveness of high-fidelity simulation in teaching contrast reaction management for residents, fellows, and attendings. A 20-question multiple-choice test assessing contrast reaction knowledge, with Likert-scale questions assessing subjective comfort levels of management of contrast reactions, was created. Three simulation scenarios that represented a moderate reaction, a severe reaction, and a contrast reaction mimic were completed in a one-hour period in a simulation laboratory. All participants completed a pretest and a posttest at one month. A six-month delayed posttest was given, but was optional for all participants. A total of 150 radiologists participated (residents = 52; fellows = 24; faculty = 74) in the pretest and posttest; and 105 participants completed the delayed posttest (residents = 31; fellows = 17; faculty = 57). A statistically significant increase was found in the one-month posttest (P < .00001) and the six-month posttest scores (P < .00001) and Likert scores (P < .001) assessing comfort level in managing all contrast reactions, compared with the pretest. Test scores and comfort level for moderate and severe reactions significantly decreased at six months, compared with the one-month posttest (P < .05). High-fidelity simulation is an effective learning tool, allowing practice of "high-acuity" situation management in a nonthreatening environment; the simulation training resulted in significant improvement in test scores, as well as an increase in subjective comfort in management of reactions, across all levels of training. A six-month refresher course is suggested, to maintain knowledge and comfort level in

  18. Optical contrast for identifying the thickness of two-dimensional materials

    Science.gov (United States)

    Bing, Dan; Wang, Yingying; Bai, Jing; Du, Ruxia; Wu, Guoqing; Liu, Liyan

    2018-01-01

    One of the most intriguing properties of two-dimensional (2D) materials is their thickness dependent properties. A quick and precise technique to identify the layer number of 2D materials is therefore highly desirable. In this review, we will introduce the basic principle of using optical contrast to determine the thickness of 2D material and also its advantage as compared to other modern techniques. Different 2D materials, including graphene, graphene oxide, transitional metal dichalcogenides, black phosphorus, boron nitride, have been used as examples to demonstrate the capability of optical contrast methods. A simple and more efficient optical contrast image technique is also emphasized, which is suitable for quick and large-scale thickness identification. We have also discussed the factors that could affect the experimental results of optical contrast, including incident light angle, anisotropic nature of materials, and also the twisted angle between 2D layers. Finally, we give perspectives on future development of optical contrast methods for the study and application of 2D materials.

  19. An Analysis of Some Variables Affecting the Internet Dependency Level of Turkish Adolescents by Using Decision Tree Methods

    Science.gov (United States)

    Kayri, Murat; Gunuc, Selim

    2010-01-01

    Internet dependency is going to expand into social life in wide area whereas it has been accepted as a pathological and psychological disease. Knowing the basic effects of internet dependency is an inevitable approach to use the internet technology healthy. In this study, internet dependency levels of 754 students were examined with the Internet…

  20. Adaptive multiscale processing for contrast enhancement

    Science.gov (United States)

    Laine, Andrew F.; Song, Shuwu; Fan, Jian; Huda, Walter; Honeyman, Janice C.; Steinbach, Barbara G.

    1993-07-01

    This paper introduces a novel approach for accomplishing mammographic feature analysis through overcomplete multiresolution representations. We show that efficient representations may be identified from digital mammograms within a continuum of scale space and used to enhance features of importance to mammography. Choosing analyzing functions that are well localized in both space and frequency, results in a powerful methodology for image analysis. We describe methods of contrast enhancement based on two overcomplete (redundant) multiscale representations: (1) Dyadic wavelet transform (2) (phi) -transform. Mammograms are reconstructed from transform coefficients modified at one or more levels by non-linear, logarithmic and constant scale-space weight functions. Multiscale edges identified within distinct levels of transform space provide a local support for enhancement throughout each decomposition. We demonstrate that features extracted from wavelet spaces can provide an adaptive mechanism for accomplishing local contrast enhancement. We suggest that multiscale detection and local enhancement of singularities may be effectively employed for the visualization of breast pathology without excessive noise amplification.

  1. Correlation analysis between bone density measured by quantitative CT and blood sugar level of aged patients with non-insulin-dependent diabetes mellitus

    International Nuclear Information System (INIS)

    Wang Guizhi; Liang Ping; Qiao Junhua; Liu Chunyan

    2008-01-01

    Objective: To approach the correlation between the bone density measured by quantitative CT and the blood sugar level of the aged patients with non-insulin-dependent diabetes mellitus, and observe the effects of the blood sugar level on the bone density. Methods: The lumbar bone densities and the blood sugar levels of 160 aged patients with non-insulin-dependent diabetes mellitus (hyperglycemia group 80 cases, euglycemia group 80 cases ) and the healthy aged people (80 cases) were detected by quantitative CT and serum biochemical detection; the correlation between the blood sugar level and the bone density and the osteoporosis occurrence status of aged people in various groups were analyzed. Results: The bone density in the non-insulin-dependent diabetes and hyperglycemia group was lower than those in normal (control) group and non-insulin-dependent diabetes and euglycemia group (P<0.05); the morbility of osteoporosis in the non-insulin-dependent diabetes and hyperglycemia group was higher than those in normal (control) group and non-insulin-dependent diabetes and euglycemia group (P<0.05); negative correlation was found between the bone density and the blood sugar level (aged male group: r=-0.7382, P=0.0013; aged female group: r=-0.8343, P=0.0007). Conclusion: The blood sugar level affects the bone density of the aged patients with non-insulin-dependent diabetes mellitus; the higher the blood sugar level, the lower the bone density. The non-insulin-dependent diabetes aged patients with hyperglycemia have the liability of osteoporosis. (authors)

  2. Myths and misconceptions concerning contrast media-induced anaphylaxis: a narrative review.

    Science.gov (United States)

    Böhm, Ingrid; Morelli, John; Nairz, Knud; Silva Hasembank Keller, Patricia; Heverhagen, Johannes T

    2017-03-01

    Contrast-enhanced radiological examinations are an increasingly important diagnostic tool in modern medicine. All approved and available contrast media (iodinated and gadolinium-based) are safe compounds that are well-tolerated by most patients. However, a small percentage of patients exhibit contrast medium-induced adverse drug reactions that are dose-dependent and predictable (type A) or an even smaller cohort experience so-called type B (dose-independent, non-predictable). To increase patients' safety, recommendations/guidelines have been put forth in the literature and advice passed down informally by radiologists in practice to ensure contrast media safety. Through these, both reasonable suggestions as well as misinterpretations and myths (such as the misleading terms "allergy-like" reactions, and "iodine-allergy", the wrong assumption that the initial contact to a contrast medium could not induce an allergy, the estimation that an anti-allergy premedication could suppress all possible adverse reactions, and interleukin-2 as a risk/trigger for contrast medium adverse events) have arisen. Since the latter are not only unhelpful but also potentially reduce patients' safety, such myths and misconceptions are the focus of this review.

  3. Evaluation of contrast visual acuity in patients with retinitis pigmentosa

    Science.gov (United States)

    Oomachi, Kazumi; Ogata, Kazuha; Sugawara, Takeshi; Hagiwara, Akira; Hata, Akira; Yamamoto, Shuichi

    2011-01-01

    Background The purpose of this study was to determine visual acuity at different contrast levels under photopic and mesopic conditions in patients with retinitis pigmentosa. Methods Sixty eyes of 31 normal controls, 92 eyes of 52 patients with retinitis pigmentosa without other ocular disorders (RP-1 group), and 20 eyes of 14 patients with retinitis pigmentosa with cataracts and without other ocular disorders (RP-2 group) were studied. Conventional visual acuity was measured using a conventional Landolt ring chart with 100% contrast and luminance of 150 cd/m2. All of the patients with retinitis pigmentosa had a decimal visual acuity better than 1.0. Contrast visual acuity was measured with the same Landolt ring chart with contrasts of 100% and 10% and under photopic (200 cd/m2) and mesopic (10 cd/m2) conditions. Decimal visual acuities were converted to logMAR units for the analyses. Results The 100% contrast visual acuity and the 10% contrast visual acuity determined under both photopic and mesopic conditions were significantly poorer in both the RP-1 and RP-2 groups than in the controls. The differences between the conventional visual acuity and the 100% contrast visual acuity were significantly greater in the RP-1 and RP-2 groups than in the controls under both photopic and mesopic conditions. The differences between the 100% contrast visual acuity and the 10% contrast visual acuity were not significant among the three groups under photopic and mesopic conditions. Conclusion Contrast visual acuities were greatly reduced in patients with retinitis pigmentosa with relatively well preserved conventional visual acuity, and the contrast visual acuity was largely influenced by ambient light levels in patients with retinitis pigmentosa. Although a longitudinal study for confirmation has to be performed, our findings indicate that contrast visual acuity is a better test to follow changes in visual function in patients with retinitis pigmentosa. PMID:22069346

  4. Multi-Level Simulated Fault Injection for Data Dependent Reliability Analysis of RTL Circuit Descriptions

    Directory of Open Access Journals (Sweden)

    NIMARA, S.

    2016-02-01

    Full Text Available This paper proposes data-dependent reliability evaluation methodology for digital systems described at Register Transfer Level (RTL. It uses a hybrid hierarchical approach, combining the accuracy provided by Gate Level (GL Simulated Fault Injection (SFI and the low simulation overhead required by RTL fault injection. The methodology comprises the following steps: the correct simulation of the RTL system, according to a set of input vectors, hierarchical decomposition of the system into basic RTL blocks, logic synthesis of basic RTL blocks, data-dependent SFI for the GL netlists, and RTL SFI. The proposed methodology has been validated in terms of accuracy on a medium sized circuit – the parallel comparator used in Check Node Unit (CNU of the Low-Density Parity-Check (LDPC decoders. The methodology has been applied for the reliability analysis of a 128-bit Advanced Encryption Standard (AES crypto-core, for which the GL simulation was prohibitive in terms of required computational resources.

  5. Recognition for old Arabic manuscripts using spatial gray level dependence (SGLD

    Directory of Open Access Journals (Sweden)

    Ahmad M. Abd Al-Aziz

    2011-03-01

    Full Text Available Texture analysis forms the basis of object recognition and classification in several domains, one of these domains is historical document manuscripts because the manuscripts hold our culture heritage and also large numbers of undated manuscripts exist. This paper presents results for historical document classification of old Arabic manuscripts using texture analysis and a segmentation free approach. The main objective is to discriminate between historical documents of different writing styles to three different ages: Contemporary (Modern Age, Ottoman Age and Mamluk Age. This classification depends on a Spatial Gray-level Dependence (SGLD technique which provides eight distinct texture features for each sample document. We applied Stepwise Discriminant Analysis and Multiple discriminant analysis methods to decrease the dimensionality of features and extract training vector features from samples. To classify historical documents into three main historical age classes the decision tree classification is applied. The system has been tested on 48 Arabic historical manuscripts documents from the Dar Al-Kotob Al-Masria Library. Our results so far yield 95.83% correct classification for the historical Arabic documents.

  6. Socio-psychological aspects, depending on the online games and the method of its diagnosis

    Directory of Open Access Journals (Sweden)

    Kochetkov N.V.

    2016-09-01

    Full Text Available The article analyzes a non-chemical type of the dependence on online games. The author considers classification and universal signs of dependence and draws the line between the two types of addictive behavior: Internet dependence and dependence on online games. In contrast to clinical characteristics used in the scientific literature, the author suggests a new criterion for identification of the dependence on the on- line games in the scientific psychological school A.V. Petrovsky — position "significant other" in real or virtual space. "Game addiction" — a new term, which is introduced in order to distinguish between the concept of gambling, dependence on online games and, dependence on the game, carried out without Internet connection. The author proposes and substantiates the socio-psychological research methodology aimed at its diagnos- tics. Empirical results that indicate differences in the level of Internet dependence and dependence on online games of respondents, depending on the factor of having "sig- nificant other” in the network, are represented.

  7. Text accessibility by people with reduced contrast sensitivity.

    Science.gov (United States)

    Crossland, Michael D; Rubin, Gary S

    2012-09-01

    Contrast sensitivity is reduced in people with eye disease, and also in older adults without eye disease. In this article, we compare contrast of text presented in print and digital formats with contrast sensitivity values for a large cohort of subjects in a population-based study of older adults (the Salisbury Eye Evaluation). Contrast sensitivity values were recorded for 2520 adults aged 65 to 84 years living in Salisbury, Maryland. The proportion of the sample likely to be unable to read text of different formats (electronic books, newsprint, paperback books, laser print, and LED computer monitors) was calculated using published contrast reserve levels required to perform spot reading, to read with fluency, high fluency, and under optimal conditions. One percent of this sample had contrast sensitivity less than that required to read newsprint fluently. Text presented on an LED computer monitor had the highest contrast. Ninety-eight percent of the sample had contrast sensitivity sufficient for high fluent reading of text (at least 160 words/min) on a monitor. However, 29.6% were still unlikely to be able to read this text with optimal fluency. Reduced contrast of print limits text accessibility for many people in the developed world. Presenting text in a high-contrast format, such as black laser print on a white page, would increase the number of people able to access such information. Additionally, making text available in a format that can be presented on an LED computer monitor will increase access to written documents.

  8. Calcium-sensitive MRI contrast agents based on superparamagnetic iron oxide nanoparticles and calmodulin.

    Science.gov (United States)

    Atanasijevic, Tatjana; Shusteff, Maxim; Fam, Peter; Jasanoff, Alan

    2006-10-03

    We describe a family of calcium indicators for magnetic resonance imaging (MRI), formed by combining a powerful iron oxide nanoparticle-based contrast mechanism with the versatile calcium-sensing protein calmodulin and its targets. Calcium-dependent protein-protein interactions drive particle clustering and produce up to 5-fold changes in T2 relaxivity, an indication of the sensors' potency. A variant based on conjugates of wild-type calmodulin and the peptide M13 reports concentration changes near 1 microM Ca(2+), suitable for detection of elevated intracellular calcium levels. The midpoint and cooperativity of the response can be tuned by mutating the protein domains that actuate the sensor. Robust MRI signal changes are achieved even at nanomolar particle concentrations (calcium levels. When combined with technologies for cellular delivery of nanoparticulate agents, these sensors and their derivatives may be useful for functional molecular imaging of biological signaling networks in live, opaque specimens.

  9. Contrast induced nephropathy

    DEFF Research Database (Denmark)

    Stacul, Fulvio; van der Molen, Aart J; Reimer, Peter

    2011-01-01

    PURPOSE: The Contrast Media Safety Committee (CMSC) of the European Society of Urogenital Radiology (ESUR) has updated its 1999 guidelines on contrast medium-induced nephropathy (CIN). AREAS COVERED: Topics reviewed include the definition of CIN, the choice of contrast medium, the prophylactic me....../min/1.73 m (2) is CIN risk threshold for intravenous contrast medium. • Hydration with either saline or sodium bicarbonate reduces CIN incidence. • Patients with eGFR = 60 ml/min/1.73 m (2) receiving contrast medium can continue metformin normally....

  10. Evaluation of contrast media submitted to ionizing radiation

    International Nuclear Information System (INIS)

    Pinho, Katia Elisa Prus; Gewehr, Pedro Miguel; Soboll, Danyel Scheidegger; Silva, Caroline Werner Pereira da; Barison, Andersson; Tilly Junior, Joao Gilberto

    2009-01-01

    Objective: the purpose of the present study was to investigate the influence of ionizing radiation from x-rays and gamma rays on the molecular structure stability of several radiologic contrast media employed in diagnostic imaging by means of 1 H and 1 3C nuclear magnetic resonance spectroscopy. Materials and methods: eight different types of iodinated contrast media (three ionic and five non-ionic) were exposed to x-rays and gamma rays irradiation. Subsequently, the 1 H and 1 3C{ 1 H} nuclear magnetic resonance spectra of these contrast media were collected. Results: the 1 H and 1 3C{ 1 H} nuclear magnetic resonance spectra of both ionic and non-ionic contrast media irradiated by x-rays or gamma rays demonstrated the absence of any alteration of the contrast media chemical composition. Conclusion: there is no problem in keeping contrast media inside examination rooms or close to radiological equipment. It is important to mention that, during the tests, the samples were directly irradiated, while in a radiology examination room, the irradiation is not direct and, therefore, radiation levels in these cases are much lower than those employed in the present study. (author)

  11. Eye contrast polarity is critical for face recognition by infants.

    Science.gov (United States)

    Otsuka, Yumiko; Motoyoshi, Isamu; Hill, Harold C; Kobayashi, Megumi; Kanazawa, So; Yamaguchi, Masami K

    2013-07-01

    Just as faces share the same basic arrangement of features, with two eyes above a nose above a mouth, human eyes all share the same basic contrast polarity relations, with a sclera lighter than an iris and a pupil, and this is unique among primates. The current study examined whether this bright-dark relationship of sclera to iris plays a critical role in face recognition from early in development. Specifically, we tested face discrimination in 7- and 8-month-old infants while independently manipulating the contrast polarity of the eye region and of the rest of the face. This gave four face contrast polarity conditions: fully positive condition, fully negative condition, positive face with negated eyes ("negative eyes") condition, and negated face with positive eyes ("positive eyes") condition. In a familiarization and novelty preference procedure, we found that 7- and 8-month-olds could discriminate between faces only when the contrast polarity of the eyes was preserved (positive) and that this did not depend on the contrast polarity of the rest of the face. This demonstrates the critical role of eye contrast polarity for face recognition in 7- and 8-month-olds and is consistent with previous findings for adults. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. On the dependence of the OH* Meinel emission altitude on vibrational level: SCIAMACHY observations and model simulations

    Directory of Open Access Journals (Sweden)

    J. P. Burrows

    2012-09-01

    Full Text Available Measurements of the OH Meinel emissions in the terrestrial nightglow are one of the standard ground-based techniques to retrieve upper mesospheric temperatures. It is often assumed that the emission peak altitudes are not strongly dependent on the vibrational level, although this assumption is not based on convincing experimental evidence. In this study we use Envisat/SCIAMACHY (Scanning Imaging Absorption spectroMeter for Atmospheric CHartographY observations in the near-IR spectral range to retrieve vertical volume emission rate profiles of the OH(3-1, OH(6-2 and OH(8-3 Meinel bands in order to investigate whether systematic differences in emission peak altitudes can be observed between the different OH Meinel bands. The results indicate that the emission peak altitudes are different for the different vibrational levels, with bands originating from higher vibrational levels having higher emission peak altitudes. It is shown that this finding is consistent with the majority of the previously published results. The SCIAMACHY observations yield differences in emission peak altitudes of up to about 4 km between the OH(3-1 and the OH(8-3 band. The observations are complemented by model simulations of the fractional population of the different vibrational levels and of the vibrational level dependence of the emission peak altitude. The model simulations reproduce the observed vibrational level dependence of the emission peak altitude well – both qualitatively and quantitatively – if quenching by atomic oxygen as well as multi-quantum collisional relaxation by O2 is considered. If a linear relationship between emission peak altitude and vibrational level is assumed, then a peak altitude difference of roughly 0.5 km per vibrational level is inferred from both the SCIAMACHY observations and the model simulations.

  13. Evaluation of potential gastrointestinal contrast agents for echoplanar MR imaging

    International Nuclear Information System (INIS)

    Reimer, P.; Schmitt, F.; Ladebeck, R.; Graessner, J.; Schaffer, B.

    1993-01-01

    The purpose of this study was to investigate approved aqueous gastrointestinal contrast agents for use in abdominal EPI. Conventional and echoplanar MR imaging experiments were performed with 1.0 Tesla whole body systems. Phantom measurements of Gastrografin, barium sulfate suspension, oral gadopentetate dimeglumine, water, and saline were performed. Signal intensity (SI) of aqueous oral barium sulfate and iodine based CT contrast agents was lower on conventional spin-echo (SE), Flash, and Turbo-Flush images than on EP images. The contrast agents exhibited higher SI on T2-weighted SE PE images and TI-time dependence on inversion recovery EP-images. The barium sulfate suspension was administered in volunteers to obtain information about bowel lumen enhancement and susceptibility artifacts. Oral administration of the aqueous barium sulfate suspension increased bowel lumen signal and reduced susceptibility artifacts. (orig.)

  14. Rapid contrast infusion of bolus injection for i.v. urography

    International Nuclear Information System (INIS)

    Kaltenborn, H.; Klose, P.; Klose, K.; Schmiedel, E.

    1993-01-01

    The rate of contrast injection during i.v. urography may vary considerably (bolus injection or drip infusion). The effect of 5 rates of injection (6, 12, 18, 36 and 72 ml/min) on the contrast density in the renal collecting system was examined over a period of 30 minutes. Measurements showed an inter-individual difference of more than 200% in each group. The intra-individual variations for different rates of injection were very slight; individual concentration in the kidney for a given dose depends only slightly on the rate of injection. There is no statistically significant improvement in contrast values as a result of a bolus injection. The reduced incidence of side effects justifies the use of bolus injections but pressure injections are unnecessary from a diagnostic point view. (orig.) [de

  15. Shoulder arthrography: comparison of morbidity after use of various contrast media

    International Nuclear Information System (INIS)

    Hall, F.M.; Goldberg, R.P.; Wyshak, G.; Kilcoyne, R.F.

    1985-01-01

    This prospective study compares immediate and delayed patient discomfort in 177 patients following shoulder arthrography using intraarticular combinations of metrizamide, meglumine/sodium diatrizoate, meglumine diatrizoate, lidocaine, epinephrine, and air. Patients receiving conventional ionic monomeric positive contrast media had a 60% (90/150) incidence of moderate or severe delayed exacerbation of their baseline symptoms; only 14% (3/21) of patients receiving metrizamide, a nonionic contrast medium had similar levels of postprocedural discomfort. Morbidity was somewhat diminished with the use of double-contrast (45%, 34/75) rather than single-contrast (75%, 56/75) examinations, and with avoidance of sodium-containing contrast agents or epinephrine. Nonionic or monovalent polymeric contrast media, despite their present high cost, may be the agents of choice if single-contrast arthrography is performed in joints associated with a high incidence of postprocedural pain

  16. Integrative curriculum reform, domain dependent knowing, and teachers` epistemological theories: Implications for middle-level teaching

    Energy Technology Data Exchange (ETDEWEB)

    Powell, R.R. [Texas Tech Univ., Lubbock, TX (United States). College of Education

    1998-12-01

    Integrative curriculum as both a theoretical construct and a practical reality, and as a theme-based, problem-centered, democratic way of schooling, is becoming more widely considered as a feasible alternative to traditional middle-level curricula. Importantly for teaching and learning, domain dependence requires teachers to view one area of knowledge as fully interdependent with other areas of knowledge during the learning process. This requires teachers to adopt personal epistemological theories that reflect integrative, domain dependent knowing. This study explored what happened when teachers from highly traditional domain independent school settings encountered an ambitious college-level curriculum project that was designed to help the teachers understand the potential that integrative, domain dependent teaching holds for precollege settings. This study asked: What influence does an integrative, domain dependent curriculum project have on teachers` domain independent, epistemological theories for teaching and learning? Finding an answer to this question is essential if we, as an educational community, are to understand how integrative curriculum theory is transformed by teachers into systemic curriculum reform. The results suggest that the integrative curriculum project that teachers participated in did not explicitly alter their classroom practices in a wholesale manner. Personal epistemological theories of teachers collectively precluded teachers from making any wholesale changes in their individual classroom teaching. However, teachers became aware of integrative curriculum as an alternative, and they expressed interest in infusing integrative practices into their classrooms as opportunities arise.

  17. Contrast Materials

    Science.gov (United States)

    ... is mixed with water before administration liquid paste tablet When iodine-based and barium-sulfate contrast materials ... for patients with kidney failure or allergies to MRI and/or computed tomography (CT) contrast material. Microbubble ...

  18. MORTALITY FROM SUICIDE AND ALCOHOLISM, DEPENDING ON THE LEVEL OF ALCOHOL CONSUMPTION

    Directory of Open Access Journals (Sweden)

    L. A. Radkevich

    2017-01-01

    Full Text Available According to WHO, the world takes place every year approximately 500 000 suicides and suicide attempts of 7 million. Since 1994, Russia ranks 2nd in the world after Lithuania, in the level of suicides, and is among the countries with the linear dependence of frequency of suicides on the level of alcohol consumption.Purpose. Install a quantitative connection between the frequency of suicide with alcohol consumption and mortality from alcoholism in the world.Material and method. For studies we used the mortality coefficient (MK from suicide and alcohol abuse (number of people/100 thousand of age standardized the population in 159 countries according to the WHO in 2004, the average daily consumption levels of alcoholic beverages: spirits, wine and beer (g/person/day according to the FAO (Food and Agriculture Organization of the United Nations. For data analysis we used correlation and regression methods.Results. We found significant positive correlation of mortality coefficient (MK from suicide for men and women with consumption of alcoholic beverages (spirits, wine and beer and mortality from alcoholism. The gender differences are revealed. Included in the regression model independent variables (levels of alcohol consumption and mortality from alcoholism explain 66% and 52% of the variability in the frequency of suicides of men and women (dependent variables. A complete rejection of the consumption of alcohol reduces the MK from suicide of men in the world at 39.5 percent, in Russia — at 76.5%; women — 37.9%, in Russia — by 54.3%. According to the regression analysis the average daily level of consumption of strong alcohol in the world is 10.4 g (3.8 kg per year for men, in Russia — 91.8 g (of 33.5 kg per year. The increase in the consumption of strong alcohol to 3 g per day (1 kg per year increases the MK from suicide in men up to 10.8% (1.6 people in the world, in Russia — 2.4% (1.6 people. The increase in the MK of alcoholism of men

  19. Contrast agents provide a faster learning curve in dipyridamole stress echocardiography.

    Science.gov (United States)

    Zamorano, Jose; Sánchez, Violeta; Moreno, Raúl; Almería, Carlos; Rodrigo, Jose; Serra, Viviana; Azcona, Luis; Aubele, Adalia; Mataix, Luis; Sánchez-Harguindey, Luis

    2002-12-01

    Interobserver variability is an important limitation of the stress echocardiography and depends on the echocardiographer training. Our aim was to evaluate if the use of contrast agents during dipyridamole stress echocardiography would improve the agreement between an experienced and a non-experienced observer in stress echo and therefore if contrast would affect the learning period of dypyridamole stress echo. Two independent observers without knowledge of any patient data interpreted all stress studies. One observer was an experienced one and the other had experience in echocardiography but not in stress echo. Two observers analysed 87 non-selected and consecutive studies. Out of the 87 studies, 46 were performed without contrast administration, whereas i.v. contrast (2.5 g Levovist by two bolus at rest and at peak stress) was administered in 41. In all cases, second harmonic imaging and stress digitalisation pack was used. The agreement between observers showed a kappa index of 0.58 and 0.83 without and with contrast administration, respectively. The use of contrast agents provides a better agreement in the evaluation of stress echo between an experienced and a non-experienced observer in stress echo. Adding routinely contrast agents could probably reduce the number of exams required for the necessary learning curve in stress echocardiography.

  20. Contrast-enhanced thoracic 3D-MR angiography in infants and children

    International Nuclear Information System (INIS)

    Holmqvist, C.; Larsson, E.M.; Staahlberg, F.; Laurin, S.

    2000-01-01

    To optimise breath-hold contrast-enhanced MR angiography (MRA) in infants and children with suspected congenital heart or thoracic vessel malformation. Thirty-nine children (median age 1 year) were examined, using five different ultrafast MRA sequences with a TR between 3.2 and 5.0 ms and the contrast agent meglumine gadoterate. A test injection was used to determine contrast travel time. Different parameters for contrast injection were evaluated. Signal-to-noise ratio (SNR) measurements were performed and image quality and injection timing were evaluated. MRA was successful in all patients and image quality was considered very good in 52%. Adequate SNR was achieved with no significant differences between the MR sequences. SNR decreased only 25 - 30% between subsequent scans. The mean contrast dose was 0.23 mmol/kg. The mean scan time was 12.5±3.8 s; the shorter scan times made dynamic examinations possible with high temporal resolution. Highest spatial resolution was obtained with TR 4.6/5.0 sequences. A contrast dose of 0.2 mmol/kg b.w. is recommended with an injection rate of 0.5 to 1.2 ml/s, depending on patient size and scan time. The scan delay time should equal the contrast travel time for optimal vessel enhancement. In the future, contrast-enhanced MRA may be a potential alternative to angiocardiography in infants and children

  1. Microbubbles as contrast agent for in-line x-ray phase-contrast imaging

    International Nuclear Information System (INIS)

    Xi Yan; Zhao Jun; Tang Rongbiao; Wang Yujie

    2011-01-01

    In the present study, we investigated the potential of gas-filled microbubbles as contrast agents for in-line x-ray phase-contrast imaging (PCI) in biomedical applications. When imaging parameters are optimized, the microbubbles function as microlenses that focus the incoming x-rays to form bright spots, which can significantly enhance the image contrast. Since microbubbles have been shown to be safe contrast agents in clinical ultrasonography, this contrast-enhancement procedure for PCI may have promising utility in biomedical applications, especially when the dose of radiation is a serious concern. In this study, we performed both numerical simulations and ex vivo experiments to investigate the formation of the contrast and the effectiveness of microbubbles as contrast agents in PCI.

  2. Exogenous attention enhances 2nd-order contrast sensitivity

    Science.gov (United States)

    Barbot, Antoine; Landy, Michael S.; Carrasco, Marisa

    2011-01-01

    Natural scenes contain a rich variety of contours that the visual system extracts to segregrate the retinal image into perceptually coherent regions. Covert spatial attention helps extract contours by enhancing contrast sensitivity for 1st-order, luminance-defined patterns at attended locations, while reducing sensitivity at unattended locations, relative to neutral attention allocation. However, humans are also sensitive to 2nd-order patterns such as spatial variations of texture, which are predominant in natural scenes and cannot be detected by linear mechanisms. We assess whether and how exogenous attention—the involuntary and transient capture of spatial attention—affects the contrast sensitivity of channels sensitive to 2nd-order, texture-defined patterns. Using 2nd-order, texture-defined stimuli, we demonstrate that exogenous attention increases 2nd-order contrast sensitivity at the attended location, while decreasing it at unattended locations, relative to a neutral condition. By manipulating both 1st- and 2nd-order spatial frequency, we find that the effects of attention depend both on 2nd-order spatial frequency of the stimulus and the observer’s 2nd-order spatial resolution at the target location. At parafoveal locations, attention enhances 2nd-order contrast sensitivity to high, but not to low 2nd-order spatial frequencies; at peripheral locations attention also enhances sensitivity to low 2nd-order spatial frequencies. Control experiments rule out the possibility that these effects might be due to an increase in contrast sensitivity at the 1st-order stage of visual processing. Thus, exogenous attention affects 2nd-order contrast sensitivity at both attended and unattended locations. PMID:21356228

  3. Effects of BDNF receptor antagonist on the severity of physical and psychological dependence, morphine-induced locomotor sensitization and the ventral tegmental area-nucleus accumbens BDNF levels in morphine- dependent and withdrawn rats.

    Science.gov (United States)

    Khalil-Khalili, Masoumeh; Rashidy-Pour, Ali; Bandegi, Ahmad Reza; Yousefi, Behpoor; Jorjani, Hassan; Miladi-Gorji, Hossein

    2018-03-06

    This study examined the effects of systemic administration of the TrkB receptor antagonist (ANA-12) on the severity of physical and psychological dependence and morphine-induced locomotor sensitization, the ventral tegmental area (VTA)-nucleus accumbens (NAc) BDNF levels in morphine-dependent and withdrawn rats. Rats were injected with bi-daily doses (10 mg/kg, at 12 h intervals) of morphine for 10 days. Then, rats were tested for naloxone-precipitated morphine withdrawal signs, the anxiety (the elevated plus maze-EPM) after the last morphine injection and injection of ANA12 (ip). Also, morphine-induced locomotor sensitization was evaluated after morphine challenge followed by an injection of ANA-12 in morphine-withdrawn rats. The VTA-NAc BDNF levels were assessed in morphine-dependent and withdrawn rats. The overall Gellert-Holtzman score was significantly higher in morphine-dependent rats receiving ANA-12 than in those receiving saline. Also, the percentage of time spent in the open arms in control and morphine-dependent rats receiving ANA-12 were higher compared to the Cont/Sal and D/Sal rats, respectively. There was no significant difference in the locomotor activity and the VTA-NAc BDNF levels between D/Sal/morphine and D/ANA-12/morphine groups after morphine withdrawal. We conclude that the systemic administration of ANA-12 exacerbates the severity of physical dependence on morphine and partially attenuates the anxiety-like behavior in morphine-dependent rats. However, ANA-12 did not affect morphine-induced locomotor sensitization and the VTA-NAc BDNF levels in morphine-dependent and withdrawn rats. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Comparison of low-contrast detectability between two CT reconstruction algorithms using voxel-based 3D printed textured phantoms.

    Science.gov (United States)

    Solomon, Justin; Ba, Alexandre; Bochud, François; Samei, Ehsan

    2016-12-01

    ) as a function of dose were constructed for each reconstruction algorithm and background texture. FBP and SAFIRE were compared for each background type to determine the improvement in detectability at a given dose, and the reduced dose at which SAFIRE had equivalent performance compared to FBP at 100% dose. Detectability increased with increasing radiation dose (P = 2.7 × 10 -59 ) and contrast level (P = 2.2 × 10 -86 ) and was higher in the uniform phantom compared to the textured phantoms (P = 6.9 × 10 -51 ). Overall, SAFIRE had higher d' compared to FBP (P = 0.02). The estimated dose reduction potential of SAFIRE was found to be 8%, 10%, 27%, and 8% for Texture-A, Texture-B, Texture-C and uniform phantoms. In all background types, detectability was higher with SAFIRE compared to FBP. However, the relative improvement observed from SAFIRE was highly dependent on the complexity of the background texture. Iterative algorithms such as SAFIRE should be assessed in the most realistic context possible.

  5. Contrast induced nephropathy

    DEFF Research Database (Denmark)

    Stacul, Fulvio; van der Molen, Aart J; Reimer, Peter

    2011-01-01

    PURPOSE: The Contrast Media Safety Committee (CMSC) of the European Society of Urogenital Radiology (ESUR) has updated its 1999 guidelines on contrast medium-induced nephropathy (CIN). AREAS COVERED: Topics reviewed include the definition of CIN, the choice of contrast medium, the prophylactic me...

  6. Generalized phase contrast:

    DEFF Research Database (Denmark)

    Glückstad, Jesper; Palima, Darwin

    Generalized Phase Contrast elevates the phase contrast technique not only to improve phase imaging but also to cross over and interface with diverse and seemingly disparate fields of contemporary optics and photonics. This book presents a comprehensive introduction to the Generalized Phase Contrast...

  7. Characterization of D-maltose as a T2 -exchange contrast agent for dynamic contrast-enhanced MRI.

    Science.gov (United States)

    Goldenberg, Joshua M; Pagel, Mark D; Cárdenas-Rodríguez, Julio

    2018-09-01

    We sought to investigate the potential of D-maltose, D-sorbitol, and D-mannitol as T 2 exchange magnetic resonance imaging (MRI) contrast agents. We also sought to compare the in vivo pharmacokinetics of D-maltose with D-glucose with dynamic contrast enhancement (DCE) MRI. T 1 and T 2 relaxation time constants of the saccharides were measured using eight pH values and nine concentrations. The effect of echo spacing in a multiecho acquisition sequence used for the T 2 measurement was evaluated for all samples. Finally, performances of D-maltose and D-glucose during T 2 -weighted DCE-MRI were compared in vivo. Estimated T 2 relaxivities (r 2 ) of D-glucose and D-maltose were highly and nonlinearly dependent on pH and echo spacing, reaching their maximum at pH = 7.0 (∼0.08 mM -1 s -1 ). The r 2 values of D-sorbitol and D-mannitol were estimated to be ∼0.02 mM -1 s -1 and were invariant to pH and echo spacing for pH ≤7.0. The change in T 2 in tumor and muscle tissues remained constant after administration of D-maltose, whereas the change in T 2 decreased in tumor and muscle after administration of D-glucose. Therefore, D-maltose has a longer time window for T 2 -weighted DCE-MRI in tumors. We have demonstrated that D-maltose can be used as a T 2 exchange MRI contrast agent. The larger, sustained T 2 -weighted contrast from D-maltose relative to D-glucose has practical advantages for tumor diagnoses during T 2 -weighted DCE-MRI. Magn Reson Med 80:1158-1164, 2018. © 2018 International Society for Magnetic Resonance in Medicine. © 2018 International Society for Magnetic Resonance in Medicine.

  8. Relaxivity of blood pool contrast agent depends on the host tissue as suggested by semianalytical simulations

    DEFF Research Database (Denmark)

    Jensen, Birgitte Fuglsang; Østergaard, Leif; Kiselev, Valerij G

    Concentration of MRI contrast agents (CA) is commonly determined indirectly using their relaxation effect. In quantitative perfusion studies, the change in the relaxation following a bolus passage is converted into concentrations assuming identical relaxivities for tissue and blood. Simulations...

  9. Modeling the time-varying and level-dependent effects of the medial olivocochlear reflex in auditory nerve responses.

    Science.gov (United States)

    Smalt, Christopher J; Heinz, Michael G; Strickland, Elizabeth A

    2014-04-01

    The medial olivocochlear reflex (MOCR) has been hypothesized to provide benefit for listening in noisy environments. This advantage can be attributed to a feedback mechanism that suppresses auditory nerve (AN) firing in continuous background noise, resulting in increased sensitivity to a tone or speech. MOC neurons synapse on outer hair cells (OHCs), and their activity effectively reduces cochlear gain. The computational model developed in this study implements the time-varying, characteristic frequency (CF) and level-dependent effects of the MOCR within the framework of a well-established model for normal and hearing-impaired AN responses. A second-order linear system was used to model the time-course of the MOCR using physiological data in humans. The stimulus-level-dependent parameters of the efferent pathway were estimated by fitting AN sensitivity derived from responses in decerebrate cats using a tone-in-noise paradigm. The resulting model uses a binaural, time-varying, CF-dependent, level-dependent OHC gain reduction for both ipsilateral and contralateral stimuli that improves detection of a tone in noise, similarly to recorded AN responses. The MOCR may be important for speech recognition in continuous background noise as well as for protection from acoustic trauma. Further study of this model and its efferent feedback loop may improve our understanding of the effects of sensorineural hearing loss in noisy situations, a condition in which hearing aids currently struggle to restore normal speech perception.

  10. Task-dependent output of human parasternal intercostal motor units across spinal levels.

    Science.gov (United States)

    Hudson, Anna L; Gandevia, Simon C; Butler, Jane E

    2017-12-01

    During breathing, there is differential activity in the human parasternal intercostal muscles and the activity is tightly coupled to the known mechanical advantages for inspiration of the same regions of muscles. It is not known whether differential activity is preserved for the non-respiratory task of ipsilateral trunk rotation. In the present study, we compared single motor units during resting breathing and axial rotation of the trunk during apnoea. We not only confirmed non-uniform recruitment of motor units across parasternal intercostal muscles in breathing, but also demonstrated that the same motor units show an altered pattern of recruitment in the non-respiratory task of trunk rotation. The output of parasternal intercostal motoneurones is modulated differently across spinal levels depending on the task and these results help us understand the mechanisms that may govern task-dependent differences in motoneurone output. During inspiration, there is differential activity in the human parasternal intercostal muscles across interspaces. We investigated whether the earlier recruitment of motor units in the rostral interspaces compared to more caudal spaces during inspiration is preserved for the non-respiratory task of ipsilateral trunk rotation. Single motor unit activity (SMU) was recorded from the first, second and fourth parasternal interspaces on the right side in five participants in two tasks: resting breathing and 'isometric' axial rotation of the trunk during apnoea. Recruitment of the same SMUs was compared between tasks (n = 123). During resting breathing, differential activity was indicated by earlier recruitment of SMUs in the first and second interspaces compared to the fourth space in inspiration (P motor units showed an altered pattern of recruitment because SMUs in the first interspace were recruited later and at a higher rotation torque than those in the second and fourth interspaces (P recruitment measures, was good-excellent [intraclass

  11. A Systems-Level Approach to Building Sustainable Assessment Cultures: Moderation, Quality Task Design and Dependability of Judgement

    Science.gov (United States)

    Colbert, Peta; Wyatt-Smith, Claire; Klenowski, Val

    2012-01-01

    This article considers the conditions that are necessary at system and local levels for teacher assessment to be valid, reliable and rigorous. With sustainable assessment cultures as a goal, the article examines how education systems can support local-level efforts for quality learning and dependable teacher assessment. This is achieved through…

  12. Association between tobacco industry denormalization beliefs, tobacco control community discontent and smokers' level of nicotine dependence.

    Science.gov (United States)

    Kushnir, Vladyslav; Selby, Peter; Cunningham, John A

    2013-07-01

    Tobacco industry denormalization (TID) informs the public about the tobacco industry's role in the tobacco epidemic and is an important component of a comprehensive tobacco control strategy. Although TID beliefs have been noted in adult smokers and associated with intent to quit, research has not evaluated whether they are affected by smokers' level of nicotine dependence. The present article sought to concurrently examine how attitudes towards the tobacco industry and tobacco control groups may differ among smokers of varying levels of nicotine dependence. In addition, it evaluated how these attitudes and beliefs may be associated with smokers' intentions to reduce or quit smoking. A random digit dialing telephone survey was conducted of 889 Canadian current daily smokers, 18 years and older. Attitudes towards the tobacco industry were mixed among the entire cohort and differences in beliefs towards the tobacco industry were not found among smokers of varying levels of nicotine dependence. However, smokers that held strong TID beliefs were 5 times more intent to quit smoking than those without such beliefs. Compared to smokers with low level of nicotine dependence, heavy smokers were more likely to report strong overall displeasure with the tobacco control community (OR=1.98, 95% CI=1.23-3.19, p=0.005), however there were no differences with regards to future intent to quit. The absence of strong negative sentiment toward the tobacco industry among smokers as a whole suggests that more targeted anti-industry messages are needed, raising greater awareness of tobacco industry practices within smokers and non-smokers alike. As heavier smokers' discontent with the tobacco control community highlights increasing social disapproval and pressure to quit smoking, future educational and media strategies used for smoking cessation purposes may benefit from emphasizing more of the positive attributes associated with quitting smoking, as opposed to the negative features of

  13. Atomic force microscope image contrast mechanisms on supported lipid bilayers.

    Science.gov (United States)

    Schneider, J; Dufrêne, Y F; Barger, W R; Lee, G U

    2000-08-01

    This work presents a methodology to measure and quantitatively interpret force curves on supported lipid bilayers in water. We then use this method to correlate topographic imaging contrast in atomic force microscopy (AFM) images of phase-separated Langmuir-Blodgett bilayers with imaging load. Force curves collected on pure monolayers of both distearoylphosphatidylethanolamine (DSPE) and monogalactosylethanolamine (MGDG) and dioleoylethanolamine (DOPE) deposited at similar surface pressures onto a monolayer of DSPE show an abrupt breakthrough event at a repeatable, material-dependent force. The breakthrough force for DSPE and MGDG is sizable, whereas the breakthrough force for DOPE is too small to measure accurately. Contact-mode AFM images on 1:1 mixed monolayers of DSPE/DOPE and MGDG/DOPE have a high topographic contrast at loads between the breakthrough force of each phase, and a low topographic contrast at loads above the breakthrough force of both phases. Frictional contrast is inverted and magnified at loads above the breakthrough force of both phases. These results emphasize the important role that surface forces and mechanics can play in imaging multicomponent biomembranes with AFM.

  14. Neurotoxicity of iodinated radiological contrast media

    International Nuclear Information System (INIS)

    Araujo Pinheiro, R.S. de

    1988-01-01

    We studied during the last ten years the neurotoxicity of artificial iodinated contrast media, with prospective clinical and experimental protocols. The experimental investigation in animals aimed to understand the relationship between the intracarotid injection, the subarachnoid application and the integrity of the blood-brain barrier function. The electro physiologic disturbances and the morphologic observation of pial circulation support the evidence that iodinated artificial contrast media induces significant alterations in brain metabolism and in the autoregulation of the blood flow of the encephalon. Even if many of such phenomena may not be apparent at the clinical level, we supposed that they are always present and that their clinical exteriorization is prevented by the immediate and effective action of homeostatic mechanisms. (author)

  15. Contrast-enhanced spectral mammography (CESM) and contrast enhanced MRI (CEMRI): Patient preferences and tolerance.

    Science.gov (United States)

    Hobbs, Max M; Taylor, Donna B; Buzynski, Sebastian; Peake, Rachel E

    2015-06-01

    Contrast-enhanced spectral mammography (CESM) may have similar diagnostic performance to Contrast-enhanced MRI (CEMRI) in the diagnosis and staging of breast cancer. To date, research has focused exclusively on diagnostic performance when comparing these two techniques. Patient experience is also an important factor when comparing and deciding on which of these modalities is preferable. The aim of this study is to compare patient experience of CESM against CEMRI during preoperative breast cancer staging. Forty-nine participants who underwent both CESM and CEMRI, as part of a larger trial, completed a Likert questionnaire about their preference for each modality according to the following criteria: comfort of breast compression, comfort of intravenous (IV) contrast injection, anxiety and overall preference. Participants also reported reasons for preferring one modality to the other. Quantitative data were analysed using a Wilcoxon sign-rank test and chi-squared test. Qualitative data are reported descriptively. A significantly higher overall preference towards CESM was demonstrated (n = 49, P < 0.001), with faster procedure time, greater comfort and lower noise level cited as the commonest reasons. Participants also reported significantly lower rates of anxiety during CESM compared with CEMRI (n = 36, P = 0.009). A significantly higher rate of comfort was reported during CEMRI for measures of breast compression (n = 49, P = 0.001) and the sensation of IV contrast injection (n = 49, P = 0.003). Our data suggest that overall, patients prefer the experience of CESM to CEMRI, adding support for the role of CESM as a possible alternative to CEMRI for breast cancer staging. © 2015 The Royal Australian and New Zealand College of Radiologists.

  16. Contrast-enhanced spectral mammography (CESM) and contrast enhanced MRI (CEMRI): Patient preferences and tolerance

    International Nuclear Information System (INIS)

    Hobbs, Max; Buzynski, Sebastian; Taylor, Donna B.; Peake, Rachel E.

    2015-01-01

    Contrast-enhanced spectral mammography (CESM) may have similar diagnostic performance to Contrast-enhanced MRI (CEMRI) in the diagnosis and staging of breast cancer. To date, research has focused exclusively on diagnostic performance when comparing these two techniques. Patient experience is also an important factor when comparing and deciding on which of these modalities is preferable. The aim of this study is to compare patient experience of CESM against CEMRI during preoperative breast cancer staging. Forty-nine participants who underwent both CESM and CEMRI, as part of a larger trial, completed a Likert questionnaire about their preference for each modality according to the following criteria: comfort of breast compression, comfort of intravenous (IV) contrast injection, anxiety and overall preference. Participants also reported reasons for preferring one modality to the other. Quantitative data were analysed using a Wilcoxon sign-rank test and chi-squared test. Qualitative data are reported descriptively. A significantly higher overall preference towards CESM was demonstrated (n = 49, P < 0.001), with faster procedure time, greater comfort and lower noise level cited as the commonest reasons. Participants also reported significantly lower rates of anxiety during CESM compared with CEMRI (n = 36, P = 0.009). A significantly higher rate of comfort was reported during CEMRI for measures of breast compression (n = 49, P = 0.001) and the sensation of IV contrast injection (n = 49, P = 0.003). Our data suggest that overall, patients prefer the experience of CESM to CEMRI, adding support for the role of CESM as a possible alternative to CEMRI for breast cancer staging.

  17. Impact of iso-osmolar versus low-osmolar contrast agents on contrast-induced nephropathy and tissue reperfusion in unselected patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention (from the Contrast Media and Nephrotoxicity Following Primary Angioplasty for Acute Myocardial Infarction [CONTRAST-AMI] Trial).

    Science.gov (United States)

    Bolognese, Leonardo; Falsini, Giovanni; Schwenke, Carsten; Grotti, Simone; Limbruno, Ugo; Liistro, Francesco; Carrera, Arcangelo; Angioli, Paolo; Picchi, Andrea; Ducci, Kenneth; Pierli, Carlo

    2012-01-01

    Conflicting data have been reported on the effects of low-osmolar and iso-osmolar contrast media on contrast-induced acute kidney injury (CI-AKI). In particular, no clinical trial has yet focused on the effect of contemporary contrast media on CI-AKI, epicardial flow, and microcirculatory function in patients with ST-segment elevation acute myocardial infarction who undergo primary percutaneous coronary intervention. The Contrast Media and Nephrotoxicity Following Coronary Revascularization by Angioplasty for Acute Myocardial Infarction (CONTRAST-AMI) trial is a prospective, randomized, single-blind, parallel-group, noninferiority study aiming to evaluate the effects of the low-osmolar contrast medium iopromide compared to the iso-osmolar agent iodixanol on CI-AKI and tissue-level perfusion in patients with ST-segment elevation acute myocardial infarction. Four hundred seventy-five consecutive, unselected patients who underwent primary percutaneous coronary intervention were randomized to iopromide (n = 239) or iodixanol (n = 236). All patients received high-dose N-acetylcysteine and hydration. The primary end point was the proportion of patients with serum creatinine (sCr) increases ≥25% from baseline to 72 hours. Secondary end points were Thrombolysis In Myocardial Infarction (TIMI) myocardial perfusion grade, increase in sCr ≥50%, increase in sCr ≥0.5 or ≥1 mg/dl, and 1-month major adverse cardiac events. The primary end point occurred in 10% of the iopromide group and in 13% of the iodixanol group (95% confidence interval -9% to 3%, p for noninferiority = 0.0002). A TIMI myocardial perfusion grade of 0 or 1 was present in 14% of patients in the 2 groups. No differences between the 2 groups were found in any of the secondary analyses of sCr increase. No significant difference in 1-month major adverse cardiac events was found (8% vs 6%, p = 0.37). In conclusion, in a population of unselected patients with ST-segment elevation acute myocardial infarction

  18. Reducing Error Rates for Iris Image using higher Contrast in Normalization process

    Science.gov (United States)

    Aminu Ghali, Abdulrahman; Jamel, Sapiee; Abubakar Pindar, Zahraddeen; Hasssan Disina, Abdulkadir; Mat Daris, Mustafa

    2017-08-01

    Iris recognition system is the most secured, and faster means of identification and authentication. However, iris recognition system suffers a setback from blurring, low contrast and illumination due to low quality image which compromises the accuracy of the system. The acceptance or rejection rates of verified user depend solely on the quality of the image. In many cases, iris recognition system with low image contrast could falsely accept or reject user. Therefore this paper adopts Histogram Equalization Technique to address the problem of False Rejection Rate (FRR) and False Acceptance Rate (FAR) by enhancing the contrast of the iris image. A histogram equalization technique enhances the image quality and neutralizes the low contrast of the image at normalization stage. The experimental result shows that Histogram Equalization Technique has reduced FRR and FAR compared to the existing techniques.

  19. FDG-PET/contrast-enhanced CT as a post-treatment tool in head and neck squamous cell carcinoma: comparison with FDG-PET/non-contrast-enhanced CT and contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Suenaga, Yuko; Kitajima, Kazuhiro; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Ishihara, Takeaki; Sasaki, Ryohei [Kobe University Graduate, School of Medicine, Department of Radiology, Division of Radiation Oncology, Kobe (Japan); Otsuki, Naoki; Nibu, Ken-ichi [Kobe University Graduate, School of Medicine, Department of Otolaryngology-Head and Neck Surgery, Kobe (Japan); Minamikawa, Tsutomu [Kobe University Graduate School of Medicine, Department of Oral and Maxillofacial Surgery, Kobe (Japan); Kiyota, Naomi [Kobe University Hospital, Department of Medical Oncology and Hematology, Kobe (Japan)

    2016-04-15

    To evaluate the accuracy of PET/CT using {sup 18}F-fluorodeoxyglucose (FDG) with IV contrast for suspected recurrent head and neck squamous cell carcinoma (HNSCC). One hundred and seventy patients previously treated for HNSCC underwent PET/CT, consisting of non-contrast-enhanced and contrast-enhanced CT, to investigate suspected recurrence. Diagnostic performance of PET/contrast-enhanced CT (PET/ceCT), PET/non-contrast-enhanced CT (PET/ncCT) and contrast-enhanced CT (ceCT) for local or regional recurrence, distant metastasis, overall recurrence and second primary cancer was evaluated. The reference standard included histopathology, treatment change and imaging follow-up. The patient-based areas under the receiver operating characteristic curves (AUC) for ceCT, PET/ncCT and PET/ceCT were 0.82, 0.96 and 0.98 for local recurrence, 0.73, 0.86 and 0.86 for regional recurrence, 0.86, 0.91 and 0.92 for distant metastasis, 0.72, 0.86 and 0.87 for overall recurrence, and 0.86, 0.89 and 0.91 for a second primary cancer. Both PET/ceCT and PET/ncCT statistically showed larger AUC than ceCT for recurrence, and the difference between PET/ceCT and PET/ncCT for local recurrence reached a significant level (p = 0.039). The accuracy of PET/ceCT for diagnosing overall recurrence was high, irrespective of the time interval after the last treatment (83.3-94.1 %). FDG-PET/CT was a more accurate HNSCC restaging tool than ceCT. The added value of ceCT at FDG-PET/CT is minimal. (orig.)

  20. Criteria for choice and use of contrast media in intra-arterial D.S.A

    International Nuclear Information System (INIS)

    Dalla-Palma, L.; Stacul, F.; Pozzi-Mucelli, R.

    1985-01-01

    The authors investigated the optimal characteristics of contrast media for use in intra-arterial DSA. 209 injections in 108 patients were evaluated, most of them in the abdominal and peripheral regions. In order to decrease contrast media osmolarity and obtain an adequate mixing with blood, contrast media with low iodine concentration were injected using the same volumes and flow rates of conventional arteriography. Good results were obtained with ionic contrast media, 100 and 150 mgI/ml. depending on the area investigated. The low concentrations allowed the use of ionic agents with an osmolarity very close to that of the non ionic contrast media: the pain has been eliminated and the heat sensation reduced. Furthermore the comparison with the cost of nonionic agents shows a great saving. (orig.)

  1. Attenuation of Morphine Physical Dependence and Blood Levels of Cortisol by Central and Systemic Administration of Ramelteon in Rat

    Directory of Open Access Journals (Sweden)

    Majid Motaghinejad

    2015-05-01

    Full Text Available Background: Chronic administration of morphine cause physical dependence but the exact mechanism of this phenomenon remains unclear. The aim of this study is the assessment of systemic and intracerebroventricular (icv administration of ramelteon (a melatonin receptor agonist on morphine physical dependence. Methods: 88 adult male rats were divided into 2 major groups, namely “systematic” and “central” administration of ramelteon. In the first category, systemic administration of ramelteon at various dosages (10, 20, and 40 mg/kg was assessed on dependent animals and withdrawal signs were compared with positive (received morphine and saline as systemic administration, negative control (saline and group under treatment by ramelteon (40 mg/kg groups. In the second category, central administration of ramelteon at various dosages (25, 50, or 100 μg, was assessed on dependent animals and withdrawal signs were compared with the positive control (received morphine and saline as icv and negative control (saline groups, and the group under treatment by ramelteon (50 μg/5 μl/rat. On the test day, all animals received naloxone (3 mg/kg and were observed for withdrawal signs. Total withdrawal score (TWS was also determined. Finally, to evaluate the stress level of dependent rats, blood cortisols were measured. Results: Central administration of ramelteon in all doses and systemic administration in high doses attenuate withdrawal syndrome in comparison with the dependent positive control group (P<0.05. Both central and systemic administrations of ramelteon can attenuate the blood cortisol level in comparison with the dependent positive control group (P<0.05. Conclusion: In conclusion, we found that central administration of ramelteon attenuated morphine withdrawal symptoms and cortisol level as a stress marker.

  2. Contrasting Foraging Patterns: Testing Resource-Concentration and Dilution Effects with Pollinators and Seed Predators

    Directory of Open Access Journals (Sweden)

    Alexandria Wenninger

    2016-06-01

    Full Text Available Resource concentration effects occur when high resource density patches attract and support more foragers than low density patches. In contrast, resource dilution effects can occur if high density patches support fewer consumers. In this study, we examined the foraging rates of pollinators and seed predators on two perennial plant species (Rudbeckia triloba and Verbena stricta as functions of resource density. Specifically, we examined whether resource-dense patches (densities of flower and seeds on individual plants resulted in greater visitation and seed removal rates, respectively. We also examined whether foraging rates were context-dependent by conducting the study in two sites that varied in resource densities. For pollinators, we found negative relationships between the density of flowers per plant and visitation rates, suggesting dilution effects. For seed predators, we found positive relationships consistent with concentration effects. Saturation effects and differences in foraging behaviors might explain the opposite relationships; most of the seed predators were ants (recruitment-based foragers, and pollinators were mostly solitary foragers. We also found that foraging rates were site-dependent, possibly due to site-level differences in resource abundance and consumer densities. These results suggest that these two plant species may benefit from producing as many flowers as possible, given high levels of pollination and low seed predation.

  3. Quality of abdominal computed tomography angiography: hand versus mechanical intravenous contrast administration in children

    Energy Technology Data Exchange (ETDEWEB)

    Ayyala, Rama S.; Lee, Edward Y. [Boston Children' s Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States); Zurakowski, David [Boston Children' s Hospital and Harvard Medical School, Departments of Anesthesiology and Surgery, Boston, MA (United States)

    2015-11-15

    Abdominal CT angiography has been increasingly used for evaluation of various conditions related to abdominal vasculature in the pediatric population. However, no direct comparison has evaluated the quality of abdominal CT angiography in children using hand versus mechanical administration of intravenous (IV) contrast agent. To compare hand versus mechanical administration of IV contrast agent in the quality of abdominal CT angiography in the pediatric population. We retrospectively reviewed the electronic medical record to identify pediatric patients (≤18 years) who had abdominal CT angiography between August 2012 and August 2013. The information obtained includes: (1) type of administration of IV contrast agent (hand [group 1] versus mechanical [group 2]), (2) size (gauge) of IV catheter, (3) amount of contrast agent administered and (4) rate of contrast agent administration (ml/s). Two reviewers independently performed qualitative and quantitative evaluation of abdominal CT angiography image quality. Qualitative evaluation of abdominal CT angiography image quality was performed by visual assessment of the degree of contrast enhancement in the region of interest (ROI) based on a 4-point scale. Quantitative evaluation of each CT angiography examination was performed by measuring the Hounsfield unit (HU) using an ROI within the abdominal aorta at two levels (celiac axis and the inferior mesenteric artery) for each child. Analysis of variance (ANOVA) using the F-test was applied to compare contrast enhancement within the abdominal aorta at two levels (celiac axis and inferior mesenteric artery) between hand administration and mechanical administration of IV contrast methods with adjustment for age. We identified 46 pediatric patients (24 male, 22 female; mean age 7.3 ± 5.5 years; range 5 weeks to 18 years) with abdominal CT angiography performed during the study period. Of these patients, 16 (35%; 1.7 ± 2.2 years; range 5 weeks to 5 years) had hand

  4. Quality of abdominal computed tomography angiography: hand versus mechanical intravenous contrast administration in children

    International Nuclear Information System (INIS)

    Ayyala, Rama S.; Lee, Edward Y.; Zurakowski, David

    2015-01-01

    Abdominal CT angiography has been increasingly used for evaluation of various conditions related to abdominal vasculature in the pediatric population. However, no direct comparison has evaluated the quality of abdominal CT angiography in children using hand versus mechanical administration of intravenous (IV) contrast agent. To compare hand versus mechanical administration of IV contrast agent in the quality of abdominal CT angiography in the pediatric population. We retrospectively reviewed the electronic medical record to identify pediatric patients (≤18 years) who had abdominal CT angiography between August 2012 and August 2013. The information obtained includes: (1) type of administration of IV contrast agent (hand [group 1] versus mechanical [group 2]), (2) size (gauge) of IV catheter, (3) amount of contrast agent administered and (4) rate of contrast agent administration (ml/s). Two reviewers independently performed qualitative and quantitative evaluation of abdominal CT angiography image quality. Qualitative evaluation of abdominal CT angiography image quality was performed by visual assessment of the degree of contrast enhancement in the region of interest (ROI) based on a 4-point scale. Quantitative evaluation of each CT angiography examination was performed by measuring the Hounsfield unit (HU) using an ROI within the abdominal aorta at two levels (celiac axis and the inferior mesenteric artery) for each child. Analysis of variance (ANOVA) using the F-test was applied to compare contrast enhancement within the abdominal aorta at two levels (celiac axis and inferior mesenteric artery) between hand administration and mechanical administration of IV contrast methods with adjustment for age. We identified 46 pediatric patients (24 male, 22 female; mean age 7.3 ± 5.5 years; range 5 weeks to 18 years) with abdominal CT angiography performed during the study period. Of these patients, 16 (35%; 1.7 ± 2.2 years; range 5 weeks to 5 years) had hand

  5. Quality of abdominal computed tomography angiography: hand versus mechanical intravenous contrast administration in children.

    Science.gov (United States)

    Ayyala, Rama S; Zurakowski, David; Lee, Edward Y

    2015-11-01

    Abdominal CT angiography has been increasingly used for evaluation of various conditions related to abdominal vasculature in the pediatric population. However, no direct comparison has evaluated the quality of abdominal CT angiography in children using hand versus mechanical administration of intravenous (IV) contrast agent. To compare hand versus mechanical administration of IV contrast agent in the quality of abdominal CT angiography in the pediatric population. We retrospectively reviewed the electronic medical record to identify pediatric patients (≤18 years) who had abdominal CT angiography between August 2012 and August 2013. The information obtained includes: (1) type of administration of IV contrast agent (hand [group 1] versus mechanical [group 2]), (2) size (gauge) of IV catheter, (3) amount of contrast agent administered and (4) rate of contrast agent administration (ml/s). Two reviewers independently performed qualitative and quantitative evaluation of abdominal CT angiography image quality. Qualitative evaluation of abdominal CT angiography image quality was performed by visual assessment of the degree of contrast enhancement in the region of interest (ROI) based on a 4-point scale. Quantitative evaluation of each CT angiography examination was performed by measuring the Hounsfield unit (HU) using an ROI within the abdominal aorta at two levels (celiac axis and the inferior mesenteric artery) for each child. Analysis of variance (ANOVA) using the F-test was applied to compare contrast enhancement within the abdominal aorta at two levels (celiac axis and inferior mesenteric artery) between hand administration and mechanical administration of IV contrast methods with adjustment for age. We identified 46 pediatric patients (24 male, 22 female; mean age 7.3 ± 5.5 years; range 5 weeks to 18 years) with abdominal CT angiography performed during the study period. Of these patients, 16 (35%; 1.7 ± 2.2 years; range 5 weeks to 5 years) had hand

  6. Experimental investigations of nonlinearities and destruction mechanisms of an experimental phospholipid-based ultrasound contrast agent.

    Science.gov (United States)

    Casciaro, Sergio; Palmizio Errico, Rosa; Errico, Rosa Palmizio; Conversano, Francesco; Demitri, Christian; Distante, Alessandro

    2007-02-01

    We sought to characterize the acoustical behavior of the experimental ultrasound contrast agent BR14 by determining the acoustic pressure threshold above which nonlinear oscillation becomes significant and investigating microbubble destruction mechanisms. We used a custom-designed in vitro setup to conduct broadband attenuation measurements at 3.5 MHz varying acoustic pressure (range, 50-190 kPa). We also performed granulometric analyses on contrast agent solutions to accurately measure microbubble size distribution and to evaluate insonification effects. Attenuation did not depend on acoustic pressure less than 100 kPa, indicating this pressure as the threshold for the appearance of microbubble nonlinear behavior. At the lowest excitation amplitude, attenuation increased during insonification, while, at higher excitation levels, the attenuation decreased over time, indicating microbubble destruction. The destruction rate changed with pressure amplitude suggesting different destruction mechanisms, as it was confirmed by granulometric analysis. Microbubbles showed a linear behavior until 100 kPa, whereas beyond this value significant nonlinearities occurred. Observed destruction phenomena seem to be mainly due to gas diffusion and bubble fragmentation mechanisms.

  7. Safety assessment of nanoparamagnetic contrast agents with different coatings for molecular MRI

    Science.gov (United States)

    Azizian, Gholamreza; Riyahi-Alam, Nader; Haghgoo, Soheila; Saffari, Mojtaba; Zohdiaghdam, Reza; Gorji, Ensieh

    2013-04-01

    Despite the wide application of gadolinium as a contrast agent for magnetic resonance imaging (MRI), there is a serious lack of information on its toxicity. Gadolinium and gadolinium oxide (Gd-oxide) are used as contrast agents for magnetic resonance imaging (MRI). There are methods for reducing toxicity of these materials, such as core nanoparticles coating or conjugating. Therefore, for toxicity evaluation, we compared the viability of commercial contrast agents in MRI (Gd-DTPA) and three nanoparticles with the same core Gd2O3 and small particulate gadolinium oxide or SPGO (DTPA. The MTT and LDH assay results showed that Gd2O3-DEG nanoparticles were more toxic than Gd-DTPA and other nanoparticles. Also, SPGO-mPEG-silane2000 was more biocompatible than other nanoparticles. The obtained results did not show any significant increase in cytotoxicity of the nanoparticles and Gd-DTPA, neither dose-dependent nor time-dependent. Therefore, DEG and PEG, due to their considerable properties and irregular sizes (different molecular weights), were selected as the useful surface covering materials of nanomagnetic particles that could reveal noticeable relaxivity and biocompatibility characteristics.

  8. Dose dependence on stochastic radiobiological effect in radiation risk estimation

    International Nuclear Information System (INIS)

    Komochkov, M.M.

    1999-01-01

    The analysis of the results in dose -- effect relationship observation has been carried out on the cell and organism levels, with the aim to obtain more precise data on the risk coefficients at low doses. The results are represented by two contrasting groups of dose dependence on effect: a downwards concave and a J-shaped curve. Both types of dependence are described by the equation solutions of an assumed unified protective mechanism, which comprises two components: constitutive and adaptive or inducible ones. The latest data analysis of the downwards concave dependence curves shows a considerable underestimation of radiation risk in all types of cancer, except leukemia, for a number of critical groups in a population, at low doses comparing to the ICRP recommendations. With the dose increase, the decrease of the effect value per dose unit is observed. It may be possibly related to the switching of the activity of the adaptive protective mechanism, with some threshold dose values being exceeded

  9. Understanding the time dependence of atomic level populations in evolving plasmas

    International Nuclear Information System (INIS)

    Judge, Philip G.

    2005-01-01

    The time dependence of atomic level populations in evolving plasmas is studied using an eigenfunction expansion of the non-LTE rate equations. The work aims to develop understanding without the need for, and as an aid to, numerical solutions. The discussion is mostly limited to linear systems, especially those for optically thin plasmas, but the implicitly non-linear case of non-LTE radiative transfer is briefly discussed. Eigenvalue spectra for typical atomic systems are examined using results compiled by Hearon. Diagonal dominance and sign symmetry of rate matrices show that just one eigenvalue is zero (corresponding to the equilibrium state), that the remaining eigenvalues have negative real parts, and that oscillations, if any, are necessarily damped. Gershgorin's theorems are used to show that many eigenvalues are determined by the radiative lifetimes of certain levels, because of diagonal dominance. With other properties, this demonstrates the existence of both 'slow' and 'fast' time-scales, where the 'slow' evolution is controlled by properties of meta-stable levels. It is shown that, when collisions are present, Rydberg states contribute only 'fast' eigenvalues. This justifies use of the quasi-static approximation, in which atoms containing just meta-stable levels can suffice to determine the atomic evolution on time-scales long compared with typical radiative lifetimes. Analytic solutions for two- and three-level atoms are used to examine the basis of earlier intuitive ideas, such as the 'ionizing plasma' approximation. The power and limitations of Gershgorin's theorems are examined through examples taken from the solar atmosphere. The methods should help in the planning and interpretation of both experimental and numerical experiments in which atomic evolution is important. While the examples are astrophysical, the methods and results are applicable to plasmas in general

  10. High contrast sensitivity for visually guided flight control in bumblebees.

    Science.gov (United States)

    Chakravarthi, Aravin; Kelber, Almut; Baird, Emily; Dacke, Marie

    2017-12-01

    Many insects rely on vision to find food, to return to their nest and to carefully control their flight between these two locations. The amount of information available to support these tasks is, in part, dictated by the spatial resolution and contrast sensitivity of their visual systems. Here, we investigate the absolute limits of these visual properties for visually guided position and speed control in Bombus terrestris. Our results indicate that the limit of spatial vision in the translational motion detection system of B. terrestris lies at 0.21 cycles deg -1 with a peak contrast sensitivity of at least 33. In the perspective of earlier findings, these results indicate that bumblebees have higher contrast sensitivity in the motion detection system underlying position control than in their object discrimination system. This suggests that bumblebees, and most likely also other insects, have different visual thresholds depending on the behavioral context.

  11. Contrast-enhanced angiographic cone-beam computed tomography without pre-diluted contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Jo, K.I.; Kim, S.R.; Choi, J.H.; Kim, K.H.; Jeon, P. [Sungkyunkwan University School of Medicine, Department of Radiology, Samsung Medical Center, Gangnam-gu, Seoul (Korea, Republic of)

    2015-11-15

    Contrast-enhanced cone-beam computed tomography (CBCT) has been introduced and accepted as a useful technique to evaluate delicate vascular anatomy and neurovascular stents. Current protocol for CBCT requires quantitative dilution of contrast medium to obtain adequate quality images. Here, we introduce simple methods to obtain contrast-enhanced CBCT without quantitative contrast dilution. A simple experiment was performed to estimate the change in flow rate in the internal carotid artery during the procedure. Transcranial doppler (TCD) was used to evaluate the velocity change before and after catheterization and fluid infusion. In addition, 0.3 cm{sup 3}/s (n = 3) and 0.2 cm{sup 3}/s (n = 7) contrast infusions were injected and followed by saline flushes using a 300 mmHg pressure bag to evaluate neurovascular stent and host arteries. Flow velocities changed -15 ± 6.8 % and +17 ± 5.5 % from baseline during catheterization and guiding catheter flushing with a 300 mmHg pressure bag, respectively. Evaluation of the stents and vascular structure was feasible using this technique in all patients. Quality assessment showed that the 0.2 cm{sup 3}/s contrast infusion protocol was better for evaluating the stent and host artery. Contrast-enhanced CBCT can be performed without quantitative contrast dilution. Adequate contrast dilution can be achieved with a small saline flush and normal blood flow. (orig.)

  12. Daylight illumination-color-contrast tables for full-form objects naturally illuminated objects

    CERN Document Server

    Nagel, M

    1978-01-01

    Daylight Illumination-Color-Contrast Tables for Full-form Objects is the result of a major computational project concerning the illumination, color, and contrast conditions in naturally illuminated objects. The project from which this two-chapter book is derived is originally conceived in support of the various remote sensing and image processing activities of the Deutsche Forschungs- und Versuchsanstalt für Luft- und Raumfahrt, Oberpfaffenhofen, West Germany DFVLR, in particular, those depending on the quantitative photometric and colorimetric evaluation of photographs and other environmental

  13. Threat-level-dependent manipulation of signaled body size: dog growls' indexical cues depend on the different levels of potential danger.

    Science.gov (United States)

    Bálint, Anna; Faragó, Tamás; Miklósi, Ádám; Pongrácz, Péter

    2016-11-01

    Body size is an important feature that affects fighting ability; however, size-related parameters of agonistic vocalizations are difficult to manipulate because of anatomical constraints within the vocal production system. Rare examples of acoustic size modulation are due to specific features that enable the sender to steadily communicate exaggerated body size. However, one could argue that it would be more adaptive if senders could adjust their signaling behavior to the fighting potential of their actual opponent. So far there has been no experimental evidence for this possibility. We tested this hypothesis by exposing family dogs (Canis familiaris) to humans with potentially different fighting ability. In a within-subject experiment, 64 dogs of various breeds consecutively faced two threateningly approaching humans, either two men or two women of different stature, or a man and a woman of similar or different stature. We found that the dogs' vocal responses were affected by the gender of the threatening stranger and the dog owner's gender. Dogs with a female owner, or those dogs which came from a household where both genders were present, reacted with growls of lower values of the Pitch-Formant component (including deeper fundamental frequency and lower formant dispersion) to threatening men. Our results are the first to show that non-human animals react with dynamic alteration of acoustic parameters related to their individual indexical features (body size), depending on the level of threat in an agonistic encounter.

  14. A prospective study on the risk of contrast induced nephropathy in the patients who underwent contrast-enhanced CT examination

    International Nuclear Information System (INIS)

    Zhang Baocui; Zhang Yudong; Zhao Kai; Wang Xiaoying; Jiang Xuexiang

    2013-01-01

    Objective: To investigate the incidence of contrast induced nephropathy (CIN) among different patient groups after contrast agent injection. Methods: A total of 1243 patients were included in this study (male = 694, female = 549). The SCr level one week before and 72 hours after the CT examination and the incidence of CIN were recorded and comparison was made among groups according to sex, age, body mass index (BMI), the history of high blood pressure (HBP), diabetes mellitus (DM), chronic kidney disease (CKD), chronic heart failure (CHF), tumor, nephrotoxicity drug (NTD) usage. The frequency, type, dose and injection velocity of the contrast media (CM) were also recorded. Multivariate predictors of CIN were identified by Logistic regression using step-wise selection with entry and exit criteria of P 1). Conclusion: Women, age ≥ 75 years, LOCM, NTD, tumor, and the frequency of using CM more than once per month were more likely to develop CIN. (authors)

  15. Interaural Level Difference Dependent Gain Control and Synaptic Scaling Underlying Binaural Computation

    Science.gov (United States)

    Xiong, Xiaorui R.; Liang, Feixue; Li, Haifu; Mesik, Lukas; Zhang, Ke K.; Polley, Daniel B.; Tao, Huizhong W.; Xiao, Zhongju; Zhang, Li I.

    2013-01-01

    Binaural integration in the central nucleus of inferior colliculus (ICC) plays a critical role in sound localization. However, its arithmetic nature and underlying synaptic mechanisms remain unclear. Here, we showed in mouse ICC neurons that the contralateral dominance is created by a “push-pull”-like mechanism, with contralaterally dominant excitation and more bilaterally balanced inhibition. Importantly, binaural spiking response is generated apparently from an ipsilaterally-mediated scaling of contralateral response, leaving frequency tuning unchanged. This scaling effect is attributed to a divisive attenuation of contralaterally-evoked synaptic excitation onto ICC neurons with their inhibition largely unaffected. Thus, a gain control mediates the linear transformation from monaural to binaural spike responses. The gain value is modulated by interaural level difference (ILD) primarily through scaling excitation to different levels. The ILD-dependent synaptic scaling and gain adjustment allow ICC neurons to dynamically encode interaural sound localization cues while maintaining an invariant representation of other independent sound attributes. PMID:23972599

  16. Contrast-enhanced harmonic ultrasound imaging in ablation therapy for primary hepatocellular carcinoma.

    Science.gov (United States)

    Minami, Yasunori; Kudo, Masatoshi

    2009-12-31

    The success rate of percutaneous radiofrequency (RF) ablation for hepatocellular carcinoma (HCC) depends on correct targeting via an imaging technique. However, RF electrode insertion is not completely accurate for residual HCC nodules because B-mode ultrasound (US), color Doppler, and power Doppler US findings cannot adequately differentiate between treated and viable residual tumor tissue. Electrode insertion is also difficult when we must identify the true HCC nodule among many large regenerated nodules in cirrhotic liver. Two breakthroughs in the field of US technology, harmonic imaging and the development of second-generation contrast agents, have recently been described and have demonstrated the potential to dramatically broaden the scope of US diagnosis of hepatic lesions. Contrast-enhanced harmonic US imaging with an intravenous contrast agent can evaluate small hypervascular HCC even when B-mode US cannot adequately characterize tumor. Therefore, contrast-enhanced harmonic US can facilitate RF ablation electrode placement in hypervascular HCC, which is poorly depicted by B-mode US. The use of contrast-enhanced harmonic US in ablation therapy for liver cancer is an efficient approach.

  17. Hyperglycaemia-induced impairment of endothelium-dependent vasorelaxation in rat mesenteric arteries is mediated by intracellular methylglyoxal levels in a pathway dependent on oxidative stress

    DEFF Research Database (Denmark)

    Brouwers, O; Niessen, P M; Haenen, G

    2010-01-01

    -hydro-5-methylimidazolone (MG-H1) was detected with an antibody against MG-H1 and quantified with ultra-performance liquid chromatography (tandem) mass spectrometry. Reactive oxygen species formation was measured with a 5-(and-6)-chloromethyl-2'7'-dichlorodihydrofluorescein diacetate acetyl ester probe...... for AGE ligand S100b did (p cells and adventitia by fivefold accompanied by an eightfold increase in the oxidative stress marker nitrotyrosine. Antioxidant pre-incubation prevented methylglyoxal......-induced impairment of vasoreactivity. CONCLUSIONS/INTERPRETATION: These data show that hyperglycaemia-induced impairment of endothelium-dependent vasorelaxation is mediated by increased intracellular methylglyoxal levels in a pathway dependent on oxidative stress....

  18. An estimation of the spatial coherency radius of a multimode laser beam by the spectral contrast

    Energy Technology Data Exchange (ETDEWEB)

    Sukhanov, I I

    1983-01-01

    The angular dependency of the spectral contrast behind a diffuser illuminated by an He/Ne laser beam at .63 micrometers on the number of transverse modes is investigated. It is demonstrated that over a wide range of scattering angles, the contrast is determined primarily by the number of transverse modes, i.e. by the radius of the spatial field correlation, and is only slightly dependent on the dimensions and shape of the beam as well as the intensity distribution in the beam. These results may be useful in developing a rapid indication method of the radius of the spatial correlation of laser beams.

  19. Phosphor plate mammography: contrast studies and clinical experience

    International Nuclear Information System (INIS)

    Chang, C.H.J.; Martin, N.L.; Templeton, A.W.; Cook, L.T.; Harrison, L.A.; McFadden, M.A.; Dwyer, S.J. III; Spicer, J.; Crystal, J.M.

    1992-01-01

    Mammography and accurate microcalcification detection require very good spatial resolution. We have compared the diagnostic capabilities of reduced-exposure, third-generation, 5 cycles/mm computed radiography (CR) phosphor plates with conventional screen-film in 67 patients. No difference in diagnostic accuracy was detected. The digital characteristics of storage phosphor plates erabled us to study the relationship between contrast and spatial resolution. We developed a computer program to identify a single 100 μm pixel in a digital image and assign various gray levels to that pixel. Using this model, we determined that, for our 5 cycles/mm CR system, the imaged contrast of a 100 μm object was 62% of the original contrast. Current 5 cycles/mm phosphor plate systems cannot adequately detect microcalcifications that approximate 100 μm or smaller unless a magnification technique is used. (orig.)

  20. Perceptual learning improves contrast sensitivity, visual acuity, and foveal crowding in amblyopia.

    Science.gov (United States)

    Barollo, Michele; Contemori, Giulio; Battaglini, Luca; Pavan, Andrea; Casco, Clara

    2017-01-01

    Amblyopic observers present abnormal spatial interactions between a low-contrast sinusoidal target and high-contrast collinear flankers. It has been demonstrated that perceptual learning (PL) can modulate these low-level lateral interactions, resulting in improved visual acuity and contrast sensitivity. We measured the extent and duration of generalization effects to various spatial tasks (i.e., visual acuity, Vernier acuity, and foveal crowding) through PL on the target's contrast detection. Amblyopic observers were trained on a contrast-detection task for a central target (i.e., a Gabor patch) flanked above and below by two high-contrast Gabor patches. The pre- and post-learning tasks included lateral interactions at different target-to-flankers separations (i.e., 2, 3, 4, 8λ) and included a range of spatial frequencies and stimulus durations as well as visual acuity, Vernier acuity, contrast-sensitivity function, and foveal crowding. The results showed that perceptual training reduced the target's contrast-detection thresholds more for the longest target-to-flanker separation (i.e., 8λ). We also found generalization of PL to different stimuli and tasks: contrast sensitivity for both trained and untrained spatial frequencies, visual acuity for Sloan letters, and foveal crowding, and partially for Vernier acuity. Follow-ups after 5-7 months showed not only complete maintenance of PL effects on visual acuity and contrast sensitivity function but also further improvement in these tasks. These results suggest that PL improves facilitatory lateral interactions in amblyopic observers, which usually extend over larger separations than in typical foveal vision. The improvement in these basic visual spatial operations leads to a more efficient capability of performing spatial tasks involving high levels of visual processing, possibly due to the refinement of bottom-up and top-down networks of visual areas.

  1. Different levels of UV-B resistance in Vaccinium corymbosum cultivars reveal distinct backgrounds of phenylpropanoid metabolites.

    Science.gov (United States)

    Luengo Escobar, Ana; Magnum de Oliveira Silva, Franklin; Acevedo, Patricio; Nunes-Nesi, Adriano; Alberdi, Miren; Reyes-Díaz, Marjorie

    2017-09-01

    UV-B radiation induces several physiological and biochemical effects that can influence regulatory plant processes. Vaccinium corymbosum responds differently to UV-B radiation depending on the UV-B resistance of cultivars, according to their physiological and biochemical features. In this work, the effect of two levels of UV-B radiation during long-term exposure on the phenylpropanoid biosynthesis, and the expression of genes associated with flavonoid biosynthesis as well as the absolute quantification of secondary metabolites were studied in two contrasting UV-B-resistant cultivars (Legacy, resistant and Bluegold, sensitive). Multivariate analyses were performed to understand the role of phenylpropanoids in UV-B defense mechanisms. The amount of phenylpropanoid compounds was generally higher in Legacy than in Bluegold. Different expression levels of flavonoid biosynthetic genes for both cultivars were transiently induced, showing that even in longer period of UV-B exposure; plants are still adjusting their phenylpropanoids at the transcription levels. Multivariate analysis in Legacy indicated no significant correlation between gene expression and the levels of the flavonoids and phenolic acids. By contrast, in the Bluegold cultivar higher number of correlations between secondary metabolite and transcript levels was found. Taken together, the results indicated different adjustments between the cultivars for a successful UV-B acclimation. While the sensitive cultivar depends on metabolite adjustments to respond to UV-B exposure, the resistant cultivar also possesses an intrinsically higher antioxidant and UV-B screening capacity. Thus, we conclude that UV-B resistance involves not only metabolite level adjustments during the acclimation period, but also depends on the intrinsic metabolic status of the plant and metabolic features of the phenylpropanoid compounds. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  2. TU-G-204-04: A Unified Strategy for Bi-Factorial Optimization of Radiation Dose and Contrast Dose in CT Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sahbaee, P; Zhang, Y; Solomon, J; Becchetti, M; Segars, P; Samei, E [Duke University Medical Center, Durham, NC (United States)

    2015-06-15

    Purpose: To substantiate the interdependency of contrast dose, radiation dose, and image quality in CT towards the patient- specific optimization of the imaging protocols Methods: The study deployed two phantom platforms. A variable sized (12, 18, 23, 30, 37 cm) phantom (Mercury-3.0) containing an iodinated insert (8.5 mgI/ml) was imaged on a representative CT scanner at multiple CTDI values (0.7–22.6 mGy). The contrast and noise were measured from the reconstructed images for each phantom diameter. Linearly related to iodine-concentration, contrast-to-noise ratio (CNR), were calculated for 16 iodine-concentration levels (0–8.5 mgI/ml). The analysis was extended to a recently developed suit of 58 virtual human models (5D XCAT) with added contrast dynamics. Emulating a contrast-enhanced abdominal image procedure and targeting a peak-enhancement in aorta, each XCAT phantom was “imaged” using a simulation platform (CatSim, GE). 3D surfaces for each patient/size established the relationship between iodine-concentration, dose, and CNR. The ratios of change in iodine-concentration versus dose (IDR) to yield a constant change in CNR were calculated for each patient size. Results: Mercury phantom results show the image-quality size- dependence on CTDI and IC levels. For desired image-quality values, the iso-contour-lines reflect the trade off between contrast-material and radiation doses. For a fixed iodine-concentration (4 mgI/mL), the IDR values for low (1.4 mGy) and high (11.5 mGy) dose levels were 1.02, 1.07, 1.19, 1.65, 1.54, and 3.14, 3.12, 3.52, 3.76, 4.06, respectively across five sizes. The simulation data from XCAT models confirmed the empirical results from Mercury phantom. Conclusion: The iodine-concentration, image quality, and radiation dose are interdependent. The understanding of the relationships between iodine-concentration, image quality, and radiation dose will allow for a more comprehensive optimization of CT imaging devices and techniques

  3. Temporal dynamics of contrast gain in single cells of the cat striate cortex.

    Science.gov (United States)

    Bonds, A B

    1991-03-01

    The response amplitude of cat striate cortical cells is usually reduced after exposure to high-contrast stimuli. The temporal characteristics and contrast sensitivity of this phenomenon were explored by stimulating cortical cells with drifting gratings in which contrast sequentially incremented and decremented in stepwise fashion over time. All responses showed a clear hysteresis, in which contrast gain dropped on average 0.36 log unit and then returned to baseline values within 60 s. Noticeable gain adjustments were seen in as little as 3 s and with peak contrasts as low as 3%. Contrast adaptation was absent in responses from LGN cells. Adaptation was found to depend on temporal frequency of stimulation, with greater and more rapid adaptation at higher temporal frequencies. Two different tests showed that the mechanism controlling response reduction was influenced primarily by stimulus contrast rather than response amplitude. These results support the existence of a rapid and sensitive cortically based system that normalizes the output of cortical cells as a function of local mean contrast. Control of the adaptation appears to arise at least in part across a population of cells, which is consistent with the idea that the gain control serves to limit the information converging from many cells onto subsequent processing areas.

  4. Differential Effect of Contrast Polarity Reversals in Closed Squares and open L-Junctions.

    Directory of Open Access Journals (Sweden)

    Mark M Schira

    2011-03-01

    Full Text Available Scene segmentation depends on interaction between geometrical and photometric factors. It has been shown that reversals in contrast polarity at points of highest orientation discontinuity along closed contours significantly impair shape discrimination performance, while changes in contrast polarity at straight(er contour segments do not have such deleterious effects (Spehar 2002. Here we employ (semi high resolution fMRI (1.5x1.5x1.5mm to investigate the neuronal substrate underlying these perception effects. Stimuli consisted of simple elements a squares with contrast reversals along straight segments; b squares with contrast reversals in the corner (highest orientation discontinuity; c L-Junctions with contrast reversals along the straight ends; d L-Junctions with contrast reversals in the corner. Element with contrast polarity reversals are easy to distinguish though appear geometrically equivalent. For squares with contrast polarity reversals only along straight lines we find significantly lower BOLD modulation compared to any of the control conditions, which show similar responses to each other. In the light of previous psychophysical work (Spehar 2002, Elder and Zucker, 1993 we speculate that this effect is due to closure perception. We observe this across a wide range of areas on occipital cortex.

  5. On film quality in barium-air double contrast colon study

    International Nuclear Information System (INIS)

    Rhu, Sang Hyung; Rhee, Jae Ho; Kim, Hai Sung; Cheung, Hwan

    1984-01-01

    The colon double contrast study provides valuable diagnostic information by means of appropriate control of Kvp and mAa when making double contrast image by injecting air into the colon after coating the colon wall by appropriately diluted Barium solution. The following experiments were performed the results of which allowed to improve the quality of film in barium-air double contrast colon study: (1) Do the pictures have uniform density when measured with a densitometer from three measuring points established in the picture by changing Kvp and mAs depending on the thickness of the patient? (2) Is the quality of the picture improved by being compensated from the adjacent area when using a wedge filter in routine check lateral decubitus and erect view? (3) What is the optimum dilution of barium solution which gives the best result for colon wall coating? The above experiments revealed that as the patient's thickness increased, it should be considered to increase mAs as well as Kvp and a wedge filter could give diagnostically very informative pictures in routine-check lateral decubitus and erect view. And 70-80% solution of Barium-water mixture provided the best quality of double contrast image

  6. The study of cardiovascular changes by intravascular injection of contrast media

    International Nuclear Information System (INIS)

    Kim, Yang Sook; Park, Chang Yoon

    1986-01-01

    This investigation was aimed to study the effect of contrast media on the cardiovascular system. So in this study, pithed rats were used whether alteration in cardiovascular system by contrast media were controlled centrally. Furthermore, several hypertonic solutions were also used to clarify the effect of contrast media. The results are as follows: 1. Intravenous injection of contrast media in rats (2.5 ml/kg) caused hypotension and bradycardia. The effects were neither blocked by pretreatment of atropine nor pyribenzamine+atropine. 2. NaCI 4.7%, dextrose 24.8%, urea 9.0% and glycerol 10.1% (v/v) which were equiosmolar with contrast media, caused hypotension, but did not affect the heart rate. 3. In pithed rats, intravenous injection of Angiografin increased blood pressure in a dose-dependant manner, and caused decrease in heart rate compared with those of control rats. 4. In pithed rats, bradycardia by intravascular injection with Angiografin was partially blocked by atropine. 5. Metrizamide of which iodine content was adjusted to 280 mg/ml caused increased in blood pressure when was injected intravenously in pithed rats with little effect on heart rate. 6. When perfused with contrast media in rat hindlimb at 15 ml/min./kg speed both perfusion pressure and flow effluent increased, simultaneously. These results suggest that hypotension might be caused by the central effect due to hyperosmolarity of contrast media and bradycardia caused by both parasympathetic stimulation and direct inhibitory action on the cardiac conductive system.

  7. Social pressure-induced craving in patients with alcohol dependence: application of virtual reality to coping skill training.

    Science.gov (United States)

    Lee, Jung Suk; Namkoong, Kee; Ku, Jeonghun; Cho, Sangwoo; Park, Ji Yeon; Choi, You Kyong; Kim, Jae-Jin; Kim, In Young; Kim, Sun I; Jung, Young-Chul

    2008-12-01

    This study was conducted to assess the interaction between alcohol cues and social pressure in the induction of alcohol craving. Fourteen male patients with alcohol dependence and 14 age-matched social drinkers completed a virtual reality coping skill training program composed of four blocks according to the presence of alcohol cues (x2) and social pressure (x2). Before and after each block, the craving levels were measured using a visual analogue scale. Patients with alcohol dependence reported extremely high levels of craving immediately upon exposure to a virtual environment with alcohol cues, regardless of social pressure. In contrast, the craving levels of social drinkers were influenced by social pressure from virtual avatars. Our findings imply that an alcohol cue-laden environment should interfere with the ability to use coping skills against social pressure in real-life situations.

  8. Nearshore hydrodynamics at pocket beaches with contrasting wave exposure in southern Portugal

    Science.gov (United States)

    Horta, João; Oliveira, Sónia; Moura, Delminda; Ferreira, Óscar

    2018-05-01

    Pocket beaches on rocky coasts with headlands that control hydro-sedimentary processes are considered to be constrained sedimentary systems, generally with limited sediment inputs. Pocket beaches face severe changes over time. Under worst-case scenarios, these changes can result in the loss of the beach, causing waves to directly attack adjacent cliffs. Studies of nearshore hydrodynamics can help to understand such changes and optimise sediment nourishment procedures. The present work contributes to the knowledge of hydrodynamic forcing mechanisms at pocket beaches by providing a comprehensive description of the nearshore circulation at two beaches with contrasting wave exposures. Two pocket beaches in southern Portugal were studied by combining field measurements of waves and currents with numerical models (STWAVE and BOUSS-2D). The aim of this analysis was to evaluate nearshore hydrodynamics under different wave exposure forcing conditions (e.g. variable wave heights/directions and different tidal levels). The results show that the beach circulation can rapidly shift from longshore-to rip-dominated depending on changes in both the offshore wave direction and tidal levels. Waves with higher obliquity (for both low and moderate wave energy conditions) tend to generate longshore circulation in all considered tidal stages, while waves with lower obliquity tend to produce rip flow with higher-velocity rip currents during low to intermediate tidal stages. The results indicate that the location and intensity of rip currents strongly depend on geomorphological constraints, that is, the control exerted by shore platforms. A larger morphological control is observed at mean sea level because most platforms are submerged/exposed during high/low tide and therefore exert less control on nearshore circulation.

  9. Spatially pooled contrast responses predict neural and perceptual similarity of naturalistic image categories.

    Directory of Open Access Journals (Sweden)

    Iris I A Groen

    Full Text Available The visual world is complex and continuously changing. Yet, our brain transforms patterns of light falling on our retina into a coherent percept within a few hundred milliseconds. Possibly, low-level neural responses already carry substantial information to facilitate rapid characterization of the visual input. Here, we computationally estimated low-level contrast responses to computer-generated naturalistic images, and tested whether spatial pooling of these responses could predict image similarity at the neural and behavioral level. Using EEG, we show that statistics derived from pooled responses explain a large amount of variance between single-image evoked potentials (ERPs in individual subjects. Dissimilarity analysis on multi-electrode ERPs demonstrated that large differences between images in pooled response statistics are predictive of more dissimilar patterns of evoked activity, whereas images with little difference in statistics give rise to highly similar evoked activity patterns. In a separate behavioral experiment, images with large differences in statistics were judged as different categories, whereas images with little differences were confused. These findings suggest that statistics derived from low-level contrast responses can be extracted in early visual processing and can be relevant for rapid judgment of visual similarity. We compared our results with two other, well- known contrast statistics: Fourier power spectra and higher-order properties of contrast distributions (skewness and kurtosis. Interestingly, whereas these statistics allow for accurate image categorization, they do not predict ERP response patterns or behavioral categorization confusions. These converging computational, neural and behavioral results suggest that statistics of pooled contrast responses contain information that corresponds with perceived visual similarity in a rapid, low-level categorization task.

  10. Spatially Pooled Contrast Responses Predict Neural and Perceptual Similarity of Naturalistic Image Categories

    Science.gov (United States)

    Groen, Iris I. A.; Ghebreab, Sennay; Lamme, Victor A. F.; Scholte, H. Steven

    2012-01-01

    The visual world is complex and continuously changing. Yet, our brain transforms patterns of light falling on our retina into a coherent percept within a few hundred milliseconds. Possibly, low-level neural responses already carry substantial information to facilitate rapid characterization of the visual input. Here, we computationally estimated low-level contrast responses to computer-generated naturalistic images, and tested whether spatial pooling of these responses could predict image similarity at the neural and behavioral level. Using EEG, we show that statistics derived from pooled responses explain a large amount of variance between single-image evoked potentials (ERPs) in individual subjects. Dissimilarity analysis on multi-electrode ERPs demonstrated that large differences between images in pooled response statistics are predictive of more dissimilar patterns of evoked activity, whereas images with little difference in statistics give rise to highly similar evoked activity patterns. In a separate behavioral experiment, images with large differences in statistics were judged as different categories, whereas images with little differences were confused. These findings suggest that statistics derived from low-level contrast responses can be extracted in early visual processing and can be relevant for rapid judgment of visual similarity. We compared our results with two other, well- known contrast statistics: Fourier power spectra and higher-order properties of contrast distributions (skewness and kurtosis). Interestingly, whereas these statistics allow for accurate image categorization, they do not predict ERP response patterns or behavioral categorization confusions. These converging computational, neural and behavioral results suggest that statistics of pooled contrast responses contain information that corresponds with perceived visual similarity in a rapid, low-level categorization task. PMID:23093921

  11. Relationship Between Collateral Status, Contrast Transit, and Contrast Density in Acute Ischemic Stroke.

    Science.gov (United States)

    Kawano, Hiroyuki; Bivard, Andrew; Lin, Longting; Spratt, Neil J; Miteff, Ferdinand; Parsons, Mark W; Levi, Christopher R

    2016-03-01

    Collateral circulation is recognized to influence the life expectancy of the ischemic penumbra in acute ischemic stroke. The best method to quantify collateral status on acute imaging is uncertain. We aimed to determine the relationship between visual collateral status, quantitative collateral assessments, baseline computed tomographic perfusion measures, and tissue outcomes on follow-up imaging. Sixty-six consecutive patients with acute ischemic stroke clinically eligible for recanalization therapy and with M1 or M2 middle cerebral artery occlusion were evaluated. We compared the visual collateral scoring with measures of contrast peak time delay and contrast peak density. We also compared these measures for their ability to predict perfusion lesion and infarct core volumes, final infarct, and infarct growth. Shorter contrast peak time delay (P=0.041) and higher contrast peak density (P=0.002) were associated with good collateral status. Shorter contrast peak time delay correlated with higher contrast peak density (β=-4.413; P=0.037). In logistic regression analysis after adjustment for age, sex, onset-computed tomographic time, and occlusion site, higher contrast peak density was independently associated with good collateral status (P=0.009). Multiple regression analysis showed that higher contrast peak density was an independent predictor of smaller perfusion lesion volume (P=0.029), smaller ischemic core volume (P=0.044), smaller follow-up infarct volume (P=0.005), and smaller infarct growth volume (P=0.010). Visual collateral status, contrast peak density, and contrast peak time delay were inter-related, and good collateral status was strongly associated with contrast peak density. Contrast peak density in collateral vessel may be an important factor in tissue fate in acute ischemic stroke. © 2016 American Heart Association, Inc.

  12. Adaptive polarimetric image representation for contrast optimization of a polarized beacon through fog

    International Nuclear Information System (INIS)

    Panigrahi, Swapnesh; Fade, Julien; Alouini, Mehdi

    2015-01-01

    We present a contrast-maximizing optimal linear representation of polarimetric images obtained from a snapshot polarimetric camera for enhanced vision of a polarized light source in obscured weather conditions (fog, haze, cloud) over long distances (above 1 km). We quantitatively compare the gain in contrast obtained by different linear representations of the experimental polarimetric images taken during rapidly varying foggy conditions. It is shown that the adaptive image representation that depends on the correlation in background noise fluctuations in the two polarimetric images provides an optimal contrast enhancement over all weather conditions as opposed to a simple difference image which underperforms during low visibility conditions. Finally, we derive the analytic expression of the gain in contrast obtained with this optimal representation and show that the experimental results are in agreement with the assumed correlated Gaussian noise model. (paper)

  13. Utility of gadolinium as a contrast medium in endovascular therapeutic procedures; Utilidad del gadolinio como medio de contraste en procedimientos terapeuticos endovasculares

    Energy Technology Data Exchange (ETDEWEB)

    Reyes, R.; Pardo, M. D.; Gorriz, E.; Gallardo, L. (Hospital de Gran Canaria Dr. Negrin); Carreira, J. M. (Universidad de Santiago de Compostela)

    2001-07-01

    To assess the utility of gadolinium associated with CO{sub 2}, as a contrast medium in angiographic studies related to endovascular therapeutic procedures in patients with suboptimal renal function. Between January 2000 and June 2001, endovascular treatments using CO{sub 2} and gadolinium as contrast medium were performed in 10 patients presenting renal function deterioration (creatinine>1.5 mg/ml). A mean dose of 42 ml of gadolinium was administered. The images acquired in diagnostic and therapeutic studied were satisfactory in every case. There was no evidence of significant increases in the previous urea and creatine levels when measured 24, 48 and 72 hours after the procedure. In combination with CO{sub 2} gadolinium is a useful contrast medium for endovascular therapeutic procedures in patients with suboptimal renal function. (Author) 21 refs.

  14. Contrast-enhanced dynamic magnetic resonance imaging findings of hepatocellular carcinoma and their correlation with histopathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Karahan, Okkes I. [Department of Radiology, Erciyes University Medical Faculty, PK: 18 Talas 38280, Kayseri (Turkey)]. E-mail: oikarahan@yahoo.com; Yikilmaz, Ali [Department of Radiology, Erciyes University Medical Faculty, PK: 18 Talas 38280, Kayseri (Turkey); Artis, Tarik [Department of General Surgery, Erciyes University Medical Faculty, PK: 18 Talas 38280, Kayseri (Turkey); Canoz, Ozlem [Department of Pathology, Erciyes University Medical Faculty, PK: 18 Talas 38280, Kayseri (Turkey); Coskun, Abdulhakim [Department of Radiology, Erciyes University Medical Faculty, PK: 18 Talas 38280, Kayseri (Turkey); Torun, Edip [Department of Internal Medicine, Division of Gastrenterology, Erciyes University Medical Faculty, PK: 18 Talas 38280, Kayseri (Turkey)

    2006-03-15

    Purpose: To investigate the correlations of contrast-enhanced magnetic resonance (MR) imaging findings of large (>5 cm) hepatocellular carcinomas with tumor size and histopathologic findings. Materials and methods: MR imaging was performed in 30 patients with a histopathologic diagnosis of hepatocellular carcinoma. The imaging protocol included non-contrast, hepatic arterial, portal venous and late phases. The signal intensities relative to the liver, enhancement patterns and the morphologic features of the lesions were evaluated in relation to size and degree of differentiation. Results: On histopathologic examination, 12 of 30 (40%) tumors were well-differentiated (grade 1), 6 of 30 (20%) were moderately differentiated (grades 2 and 3) and 12 of 30 (40%) were poorly differentiated (grade 4). Tumor size, tumor boundary, serum alpha-fetoprotein level and portal vein invasion were found to have statistically significant correlations with the degree of differentiation (p < 0.05). Portal vein invasion, capsule formation and tumor surface characteristics showed statistically significant correlations with tumor size (p < 0.05). Conclusion: MR imaging findings of hepatocellular carcinomas larger than 5 cm are partially dependent on tumor size and degree of differentiation.

  15. Exploring Secondary Students' Epistemological Features Depending on the Evaluation Levels of the Group Model on Blood Circulation

    Science.gov (United States)

    Lee, Shinyoung; Kim, Heui-Baik

    2014-01-01

    The purpose of this study is to identify the epistemological features and model qualities depending on model evaluation levels and to explore the reasoning process behind high-level evaluation through small group interaction about blood circulation. Nine groups of three to four students in the eighth grade participated in the modeling practice.…

  16. Exogenous contrast agents for thermoacoustic imaging: An investigation into the underlying sources of contrast

    International Nuclear Information System (INIS)

    Ogunlade, Olumide; Beard, Paul

    2015-01-01

    Purpose: Thermoacoustic imaging at microwave excitation frequencies is limited by the low differential contrast exhibited by high water content tissues. To overcome this, exogenous thermoacoustic contrast agents based on gadolinium compounds, iron oxide, and single wall carbon nanotubes have previously been suggested and investigated. However, these previous studies did not fully characterize the electric, magnetic, and thermodynamic properties of these agents thus precluding identification of the underlying sources of contrast. To address this, measurements of the complex permittivity, complex permeability, DC conductivity, and Grüneisen parameter have been made. These measurements allowed the origins of the contrast provided by each substance to be identified. Methods: The electric and magnetic properties of the contrast agents were characterized at 3 GHz using two rectangular waveguide cavities. The DC conductivity was measured separately using a conductivity meter. Thermoacoustic signals were then acquired and compared to those generated in water. Finally, 3D electromagnetic simulations were used to decouple the different contributions to the absorbed power density. Results: It was found that the gadolinium compounds provided appreciable electric contrast but not originating from the gadolinium itself. The contrast was either due to dissociation of the gadolinium salt which increased ionic conductivity or its nondissociated polar fraction which increased dielectric polarization loss or a combination of both. In addition, very high concentrations were required to achieve appreciable contrast, to the extent that the Grüneisen parameter increased significantly and became a source of contrast. Iron oxide particles were found to produce low but measurable dielectric contrast due to dielectric polarization loss, but this is attributed to the coating of the particles not the iron oxide. Single wall carbon nanotubes did not provide measurable contrast of any type

  17. Exogenous contrast agents for thermoacoustic imaging: An investigation into the underlying sources of contrast

    Energy Technology Data Exchange (ETDEWEB)

    Ogunlade, Olumide, E-mail: o.ogunlade@ucl.ac.uk; Beard, Paul [Department of Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT (United Kingdom)

    2015-01-15

    Purpose: Thermoacoustic imaging at microwave excitation frequencies is limited by the low differential contrast exhibited by high water content tissues. To overcome this, exogenous thermoacoustic contrast agents based on gadolinium compounds, iron oxide, and single wall carbon nanotubes have previously been suggested and investigated. However, these previous studies did not fully characterize the electric, magnetic, and thermodynamic properties of these agents thus precluding identification of the underlying sources of contrast. To address this, measurements of the complex permittivity, complex permeability, DC conductivity, and Grüneisen parameter have been made. These measurements allowed the origins of the contrast provided by each substance to be identified. Methods: The electric and magnetic properties of the contrast agents were characterized at 3 GHz using two rectangular waveguide cavities. The DC conductivity was measured separately using a conductivity meter. Thermoacoustic signals were then acquired and compared to those generated in water. Finally, 3D electromagnetic simulations were used to decouple the different contributions to the absorbed power density. Results: It was found that the gadolinium compounds provided appreciable electric contrast but not originating from the gadolinium itself. The contrast was either due to dissociation of the gadolinium salt which increased ionic conductivity or its nondissociated polar fraction which increased dielectric polarization loss or a combination of both. In addition, very high concentrations were required to achieve appreciable contrast, to the extent that the Grüneisen parameter increased significantly and became a source of contrast. Iron oxide particles were found to produce low but measurable dielectric contrast due to dielectric polarization loss, but this is attributed to the coating of the particles not the iron oxide. Single wall carbon nanotubes did not provide measurable contrast of any type

  18. Contrasting Academic Behavioural Confidence in Mexican and European Psychology Students

    Science.gov (United States)

    Ochoa, Alma Rosa Aguila; Sander, Paul

    2012-01-01

    Introduction: Research with the Academic Behavioural Confidence scale using European students has shown that students have high levels of confidence in their academic abilities. It is generally accepted that people in more collectivist cultures have more realistic confidence levels in contrast to the overconfidence seen in individualistic European…

  19. Effects of exercise training on glucose control, lipid metabolism, and insulin sensitivity in hypertriglyceridemia and non-insulin dependent diabetes mellitus.

    Science.gov (United States)

    Lampman, R M; Schteingart, D E

    1991-06-01

    Exercise training has potential benefits for patients with hyperlipidemia and/or non-insulin dependent diabetes mellitus. In nondiabetic, nonobese subjects with hypertriglyceridemia, exercise training alone increased insulin sensitivity, improved glucose tolerance, and lowered serum triglyceride and cholesterol levels. These improvements did not occur when exercise training alone was given to similar patients with impaired glucose tolerance. In severely obese (X = 125 kg) subjects without diabetes melitus, a 600 calorie diet alone decreased glucose and insulin concentrations and improved glucose tolerance but did not increase insulin sensitivity. The addition of exercise training improved insulin sensitivity. Obese, non-insulin dependent diabetes mellitus subjects on sulfonylurea therapy alone increased insulin levels but failed to improve insulin sensitivity or glucose levels. In contrast, the addition of exercise training to this medication resulted in improved insulin sensitivity and lowered glucose levels. We conclude that exercise training has major effects on lowering triglyceride levels in hyperlipidemic subjects and can potentiate the effect of diet or drug therapy on glucose metabolism in patients with non-insulin dependent diabetes mellitus.

  20. Perforations during contrast enema

    International Nuclear Information System (INIS)

    Vogel, H.; Steinkamp, U.; Grabbe, E.; Allgemeines Krankenhaus Ochsenzoll, Hamburg

    1983-01-01

    During contrast enema, perforation into the retroperitoneal space can be differentiated from perforation into the peritoneum and perforation into the intestinal wall associated with formation of barium granulomas or submucosal spreading of the contrast medium. Other special forms are perforation with contrast medium embolism of diverticula; of the processus vermiformis; penetration of contrast medium into fistulous systems and from the operated areas. Risk factors are: balloon catheter, intestinal tubes with a hard tip, preternatural anus, excessive enema pressure, contrast medium additions, preceding manipulations, intestinal diseases, advanced age and delegation of manipulations to assistants and unskilled staff. Children are particularly at risk. (orig.) [de

  1. The Effects of Text Density Levels and the Cognitive Style of Field Dependence on Learning from a CBI Tutorial

    Science.gov (United States)

    Ipek, Ismail

    2011-01-01

    The purpose of this study was to investigate the effects of variations in text density levels and the cognitive style of field dependence on learning from a CBI tutorial, based on the dependent measures of achievement, reading comprehension, and reading rate, and of lesson completion time. Eighty college undergraduate students were randomly…

  2. Upper Limb Asymmetry in the Sense of Effort Is Dependent on Force Level

    Directory of Open Access Journals (Sweden)

    Diane E. Adamo

    2017-04-01

    Full Text Available Previous studies have shown that asymmetries in upper limb sensorimotor function are dependent on the source of sensory and motor information, hand preference and differences in hand strength. Further, the utilization of sensory and motor information and the mode of control of force may differ between the right hand/left hemisphere and left hand/right hemisphere systems. To more clearly understand the unique contribution of hand strength and intrinsic differences to the control of grasp force, we investigated hand/hemisphere differences when the source of force information was encoded at two different force levels corresponding to a 20 and 70% maximum voluntary contraction or the right and left hand of each participant. Eleven, adult males who demonstrated a stronger right than left maximum grasp force were requested to match a right or left hand 20 or 70% maximal voluntary contraction reference force with the opposite hand. During the matching task, visual feedback corresponding to the production of the reference force was available and then removed when the contralateral hand performed the match. The matching relative force error was significantly different between hands for the 70% MVC reference force but not for the 20% MVC reference force. Directional asymmetries, quantified as the matching force constant error, showed right hand overshoots and left undershoots were force dependent and primarily due to greater undershoots when matching with the left hand the right hand reference force. Findings further suggest that the interaction between internal sources of information, such as efferent copy and proprioception, as well as hand strength differences appear to be hand/hemisphere system dependent. Investigations of force matching tasks under conditions whereby force level is varied and visual feedback of the reference force is available provides critical baseline information for building effective interventions for asymmetric (stroke

  3. Association Between Contrast Media Volume-Glomerular Filtration Rate Ratio and Contrast-Induced Acute Kidney Injury After Primary Percutaneous Coronary Intervention.

    Science.gov (United States)

    Celik, Omer; Ozturk, Derya; Akin, Fatih; Ayca, Burak; Yalcın, Ahmet Arif; Erturk, Mehmet; Bıyık, Ismail; Ayaz, Ahmet; Akturk, Ibrahim Faruk; Enhos, Asım; Aslan, Serkan

    2015-07-01

    We hypothesized that contrast media volume-estimated glomerular filtration rate (CV-e-GFR) ratio may be a predictor of contrast media-induced acute kidney injury (CI-AKI). We investigated the associations between CV-e-GFR ratio and CI-AKI in 597 patients undergoing primary percutaneous coronary intervention (pPCI). An absolute ≥0.3 mg/dL increase in serum creatinine compared with baseline levels within 48 hours after the procedure was considered as CI-AKI; 78 (13.1%) of the 597 patients experienced CI-AKI. The amount of contrast during procedure was higher in the CI-AKI group than in those without CI-AKI (153 vs 135 mL, P = .003). The CV-e-GFR ratio was significantly higher in patients with CI-AKI than without (2.3 vs 1.5, P 2 (P < .001, OR = 5.917). In conclusion, CV-e-GFR ratio is significantly associated with CI-AKI after pPCI. © The Author(s) 2014.

  4. Motion-dependent levels of order in a relativistic universe.

    Science.gov (United States)

    Frieden, B Roy; Petri, Michael

    2012-09-01

    Consider a generally closed system of continuous three-space coordinates x with a differentiable amplitude function ψ(x). What is its level of order R? Define R by the property that it decreases (or stays constant) after the system is coarse grained. Then R turns out to obey R=8(-1)L(2)I,where quantity I=4∫dx[nabla]ψ(*)·[nabla]ψ is the classical Fisher information in the system and L is the longest chord that can connect two points on the system surface. In general, order R is (i) unitless, and (ii) invariant to uniform stretch or compression of the system. On this basis, the order R in the Universe was previously found to be invariant in time despite its Hubble expansion, and with value R=26.0×10(60) for flat space. By comparison, here we model the Universe as a string-based "holostar," with amplitude function ψ(x)[proportionality]1/r over radial interval r=(r(0),r(H)). Here r(0) is of order the Planck length and r(H) is the radial extension of the holostar, estimated as the known value of the Hubble radius. Curvature of space and relative motion of the observer must now be taken into account. It results that a stationary observer observes a level of order R=(8/9)(r(H)/r(0))(3/2)=0.42×10(90); while for a free-falling observer R=2(-1)(r(H)/r(0))(2)=0.85×10(120). Both order values greatly exceed the above flat-space value. Interestingly, they are purely geometric measures, depending solely upon ratio r(H)/r(0). Remarkably, the free-fall value ~10(120) of R approximates the negentropy of a universe modeled as discrete. This might mean that the Universe contains about equal amounts of continuous and discrete structure.

  5. Gadolinium Deposition in Human Brain Tissues after Contrast-enhanced MR Imaging in Adult Patients without Intracranial Abnormalities.

    Science.gov (United States)

    McDonald, Robert J; McDonald, Jennifer S; Kallmes, David F; Jentoft, Mark E; Paolini, Michael A; Murray, David L; Williamson, Eric E; Eckel, Laurence J

    2017-11-01

    Purpose To determine whether gadolinium deposits in neural tissues of patients with intracranial abnormalities following intravenous gadolinium-based contrast agent (GBCA) exposure might be related to blood-brain barrier integrity by studying adult patients with normal brain pathologic characteristics. Materials and Methods After obtaining antemortem consent and institutional review board approval, the authors compared postmortem neuronal tissue samples from five patients who had undergone four to 18 gadolinium-enhanced magnetic resonance (MR) examinations between 2005 and 2014 (contrast group) with samples from 10 gadolinium-naive patients who had undergone at least one MR examination during their lifetime (control group). All patients in the contrast group had received gadodiamide. Neuronal tissues from the dentate nuclei, pons, globus pallidus, and thalamus were harvested and analyzed with inductively coupled plasma mass spectrometry (ICP-MS), transmission electron microscopy with energy-dispersive x-ray spectroscopy, and light microscopy to quantify, localize, and assess the effects of gadolinium deposition. Results Tissues from the four neuroanatomic regions of gadodiamide-exposed patients contained 0.1-19.4 μg of gadolinium per gram of tissue in a statistically significant dose-dependent relationship (globus pallidus: ρ = 0.90, P = .04). In contradistinction, patients in the control group had undetectable levels of gadolinium with ICP-MS. All patients had normal brain pathologic characteristics at autopsy. Three patients in the contrast group had borderline renal function (estimated glomerular filtration rate the contrast group was localized to the capillary endothelium and neuronal interstitium and, in two cases, within the nucleus of the cell. Conclusion Gadolinium deposition in neural tissues after GBCA administration occurs in the absence of intracranial abnormalities that might affect the permeability of the blood-brain barrier. These findings

  6. Development of contrast media

    International Nuclear Information System (INIS)

    Krause, W.

    1993-01-01

    Description of all contrast media (ionic and nonionic monomers, ionic and nonionic dimers) was presented. Chemotoxicity, osmolality and viscosity of some contrast agents were analyzed. The main adverse reactions to ionic and nonionic contrast media were described

  7. Clinical evaluation of contrast-enhanced digital mammography and contrast enhanced tomosynthesis--Comparison to contrast-enhanced breast MRI.

    Science.gov (United States)

    Chou, Chen-Pin; Lewin, John M; Chiang, Chia-Ling; Hung, Bao-Hui; Yang, Tsung-Lung; Huang, Jer-Shyung; Liao, Jia-Bin; Pan, Huay-Ben

    2015-12-01

    To compare the diagnostic accuracy of contrast-enhanced digital mammography (CEDM) and contrast-enhanced tomosynthesis (CET) to dynamic contrast enhanced breast MRI (DCE-MRI) using a multireader-multicase study. Institutional review board approval and informed consents were obtained. Total 185 patients (mean age 51.3) with BI-RADS 4 or 5 lesions were evaluated before biopsy with mammography, tomosynthesis, CEDM, CET and DCE-MRI. Mediolateral-oblique and cranio-caudal views of the target breast CEDM and CET were acquired at 2 and 4 min after contrast agent injection. A mediolateral-oblique view of the non-target breast was taken at 6 min. Each lesion was scored with forced BI-RADS categories by three readers. Each reader interpreted lesions in the following order: mammography, tomosynthesis, CEDM, CET, and DCE-MRI during a single reading session. Histology showed 81 cancers and 144 benign lesions in the study. Of the 81 malignant lesions, 44% (36/81) were invasive and 56% (45/81) were non-invasive. Areas under the ROC curve, averaged for the 3 readers, were as follows: 0.897 for DCE-MRI, 0.892 for CET, 0.878 for CEDM, 0.784 for tomosynthesis and 0.740 for mammography. Significant differences in AUC were found between the group of contrast enhanced modalities (CEDM, CET, DCE-MRI) and the unenhanced modalities (all p0.05). CET and CEDM may be considered as an alternative modality to MRI for following up women with abnormal mammography. All three contrast modalities were superior in accuracy to conventional digital mammography with or without tomosynthesis. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  8. Studies of the effects of control bandwidth and dark-hole size on the HCIT contrast performance

    Science.gov (United States)

    Sidick, Erkin; Shaklan, Stuart; Balasubramanian, Kunjithapatham; Cady, Eric

    2015-09-01

    We have carried out both theoretical and experimental studies of the sensitivity of dark hole contrast to the control bandwidth and dark-hole dimensions in high-contrast broadband stellar coronagraphy. We have evaluated the performance of DM actuator solutions in the presence of occulting mask defects using one to five 2%-wide bands spanning a 10% bandpass. We have also investigated the dependence of the HCIT contrast performance on the size of dark-hole area including large dark holes formed at the Nyquist limit of the DM.

  9. Dynamic vision based on motion-contrast: changes with age in adults.

    Science.gov (United States)

    Wist, E R; Schrauf, M; Ehrenstein, W H

    2000-10-01

    Data are presented for a computerized test of dynamic vision in a sample of 1006 healthy subjects aged between 20 and 85 years. The test employed a form-from-motion stimulus: i.e., within a random-dot display, Landolt rings of the same average luminance as their surroundings become visible only when the dots within the ring are moved briefly, while those of the surround remain stationary. Thus, detection of gap location is based upon motion contrast (form-from-motion) rather than luminance contrast. With the size and exposure duration of the centrally presented ring held constant, motion contrast was manipulated by varying the percentage (between 20 and 100%) of moving dots within the ring. Subjects reported gap location (left, right, top, bottom). A gradual decline of dynamic vision with age was found for all motion-contrast levels. Beyond 70 years of age, chance-level performance occurred in almost half of the subjects. The data provide the basis for applications including diagnostic screening for glaucoma, visual disturbances in brain-damaged patients, as well as assessment of the dynamic vision of drivers of motor vehicles and athletes.

  10. Influence of MRI contrast media on histamine release from mast cells.

    Science.gov (United States)

    Kun, Tomasz; Jakubowski, Lucjusz

    2012-07-01

    Mast cells, owing to diversity of secreted mediators, play a crucial role in the regulation of inflammatory response. Together with basophils, mast cells constitute a central pathogenetic element of anaphylactic (IgE-dependent) and anaphylactoid (IgE-independent) reactions. In severe cases, generalized degranulation of mast cells may cause symptoms of anaphylactic shock. The influence of the classical, iodine-based contrast media on mastocyte degranulation has been fully described. Our objective was to determine the influence of the gadolinium-based MRI contrast media on histamine release from mast cells and to compare the activity of ionic and non-ionic preparations of contrast media. To determine the intensity of mast cell degranulation, we used an experimental model based on mastocytes isolated from rat peritoneal fluid. Purified suspensions of mast cells were incubated with various concentrations of Gd-DTPA and Gd-DTPA-BMA, and solutions of PEG 600 which served as a non-toxic osmotic stimulus. The intensity of mast cell activation was presented as mean percentage of histamine released from cells after incubation. The obtained results demonstrate that both ionic and non-ionic preparations of the MRI contrast media are able to induce mast cell degranulation in vitro. It was also proved that the non-ionic MRI contrast media stimulate mast cells markedly more weakly than ionic contrast media at identical concentration. The aforementioned results may suggest a more profitable safety profile of the non-ionic contrast preparations. We may also conclude that triggering of mast cell degranulation after incubation with the solutions of MRI contrast media results from non-specific osmotic stimulation and direct toxicity of free ionic residues.

  11. Influence of MRI contrast media on histamine release from mast cells

    International Nuclear Information System (INIS)

    Kun, Tomasz; Jakubowski, Lucjusz

    2012-01-01

    Mast cells, owing to diversity of secreted mediators, play a crucial role in the regulation of inflammatory response. Together with basophils, mast cells constitute a central pathogenetic element of anaphylactic (IgE-dependent) and anaphylactoid (IgE-independent) reactions. In severe cases, generalized degranulation of mast cells may cause symptoms of anaphylactic shock. The influence of the classical, iodine-based contrast media on mastocyte degranulation has been fully described. Our objective was to determine the influence of the gadolinium-based MRI contrast media on histamine release from mast cells and to compare the activity of ionic and non-ionic preparations of contrast media. To determine the intensity of mast cell degranulation, we used an experimental model based on mastocytes isolated from rat peritoneal fluid. Purified suspensions of mast cells were incubated with various concentrations of Gd-DTPA and Gd-DTPA-BMA, and solutions of PEG 600 which served as a non-toxic osmotic stimulus. The intensity of mast cell activation was presented as mean percentage of histamine released from cells after incubation. The obtained results demonstrate that both ionic and non-ionic preparations of the MRI contrast media are able to induce mast cell degranulation in vitro. It was also proved that the non-ionic MRI contrast media stimulate mast cells markedly more weakly than ionic contrast media at identical concentration. The aforementioned results may suggest a more profitable safety profile of the non-ionic contrast preparations. We may also conclude that triggering of mast cell degranulation after incubation with the solutions of MRI contrast media results from non-specific osmotic stimulation and direct toxicity of free ionic residues

  12. Contrast media in computed tomography of the mediastinum and the lung

    International Nuclear Information System (INIS)

    Wegener, O.-H.; Claussen, C.D.

    1981-01-01

    An administration of contrast medium is frequently indicated for problems of mediastinal diagnosis. The reason for this is that previous diagnosis or a clear set of clinical symptoms justifies the suspicion of a space-occupying process. Moreover, CT should lead to diagnoses which are as definite and differentiated as possible. In the majority of examinations, contrast media should be applied to evaluate the mediastinum. Infusion technique is suitable for extensive or disseminated processes, whereby the dose depends on the duration of the examination. An intravasal enhancement exceeding 60 Hounsfield Units (HU) should be achieved for the entire period. For focal lesions bolus injections should be used to clarify the degree of vascularization of the expected process. Besides site and radiodensity, it is the degree of vascularization that narrows down the differential diagnosis in mediastinal disease. At present an indication for application of contrast media in lung diseases does not exist. (Auth.)

  13. When size matters: attention affects performance by contrast or response gain.

    Science.gov (United States)

    Herrmann, Katrin; Montaser-Kouhsari, Leila; Carrasco, Marisa; Heeger, David J

    2010-12-01

    Covert attention, the selective processing of visual information in the absence of eye movements, improves behavioral performance. We found that attention, both exogenous (involuntary) and endogenous (voluntary), can affect performance by contrast or response gain changes, depending on the stimulus size and the relative size of the attention field. These two variables were manipulated in a cueing task while stimulus contrast was varied. We observed a change in behavioral performance consonant with a change in contrast gain for small stimuli paired with spatial uncertainty and a change in response gain for large stimuli presented at one location (no uncertainty) and surrounded by irrelevant flanking distracters. A complementary neuroimaging experiment revealed that observers' attention fields were wider with than without spatial uncertainty. Our results support important predictions of the normalization model of attention and reconcile previous, seemingly contradictory findings on the effects of visual attention.

  14. Dependence of critical current properties on growth temperature and doping level of nanorods in PLD-YBa2Cu3Oy films

    International Nuclear Information System (INIS)

    Fujita, N.; Haruta, M.; Ichinose, A.; Maeda, T.; Horii, S.

    2013-01-01

    Highlights: •We fabricated Y123 films with Ba–Nb–O nanorods at various growth temperatures. •Irreversibility lines depended on growth temperature and doping level of Ba–Nb–O. •Nanorod morphology was drastically changed by growth temperature (T s ). •Its T s dependence of the matching field was different from that for Er123 + Ba–Nb–O. -- Abstract: The vortex-Bose-glass-like irreversibility lines (ILs) emerged for 2.5 and 5.0 at.% Ba–Nb–O (BNO)-doped YBa 2 Cu 3 O y films deposited by PLD using Nd:YAG-laser. The ILs strongly depended on growth temperature (T s ) in addition to the doping level of BNO. The vortex glass region was expanded with increasing T s or doping level of BNO. Drastic change of the nanorod morphology from short and bended nanorods to long and linear nanorods with increasing T s was clarified. Moreover, it was found that T s -dependent ILs were quite different from our previous results in BNO-doped ErBa 2 Cu 3 O y films

  15. Octopamine regulates antennal sensory neurons via daytime-dependent changes in cAMP and IP3 levels in the hawkmoth Manduca sexta.

    Directory of Open Access Journals (Sweden)

    Thomas Schendzielorz

    Full Text Available The biogenic amine octopamine (OA mediates reward signals in olfactory learning and memory as well as circadian rhythms of sleep and activity. In the crepuscular hawkmoth Manduca sexta, OA changed pheromone detection thresholds daytime-dependently, suggesting that OA confers circadian control of olfactory transduction. Thus, with enzyme-linked immunosorbent assays we searched hawkmoth antennae for daytime-dependent changes in the concentration of OA and its respective second messengers. Antennal stimulation with OA raised cAMP- and IP3 levels. Furthermore, antennae expressed daytime-dependent changes in the concentration of OA, with maxima at Zeitgebertime (ZT 20 when moths were active and also maximal concentrations of cAMP occurred. Maximal IP3 levels at ZT 18 and 23 correlated with maximal flight activity of male moths, while minimal IP3 levels at dusk correlated with peaks of feeding activity. Half maximal effective concentration (EC50 for activation of the OA-receptor decreased during the moth's activity phase suggesting daytime-dependent changes in OA receptor sensitivity. With an antiserum against tyramine, the precursor of OA, two centrifugal neurons were detected projecting out into the sensory cell layer of the antenna, possibly mediating more rapid stimulus-dependent OA actions. Indeed, in fast kinetic assays OA receptor stimulation increased cAMP concentrations within 50 msec. Thus, we hypothesize that fast, stimulus-dependent centrifugal control of OA-release in the antenna occurs. Additional slow systemic OA actions might be based upon circadian release of OA into the hemolymph mediating circadian rhythms of antennal second messenger levels. The resulting rhythms of odor sensitivity are suggested to underlie circadian rhythms in odor-mediated behavior.

  16. Memory and pattern storage in neural networks with activity dependent synapses

    Science.gov (United States)

    Mejias, J. F.; Torres, J. J.

    2009-01-01

    We present recently obtained results on the influence of the interplay between several activity dependent synaptic mechanisms, such as short-term depression and facilitation, on the maximum memory storage capacity in an attractor neural network [1]. In contrast with the case of synaptic depression, which drastically reduces the capacity of the network to store and retrieve activity patterns [2], synaptic facilitation is able to enhance the memory capacity in different situations. In particular, we find that a convenient balance between depression and facilitation can enhance the memory capacity, reaching maximal values similar to those obtained with static synapses, that is, without activity-dependent processes. We also argue, employing simple arguments, that this level of balance is compatible with experimental data recorded from some cortical areas, where depression and facilitation may play an important role for both memory-oriented tasks and information processing. We conclude that depressing synapses with a certain level of facilitation allow to recover the good retrieval properties of networks with static synapses while maintaining the nonlinear properties of dynamic synapses, convenient for information processing and coding.

  17. Analysis of contrast and absorbed doses in mammography

    International Nuclear Information System (INIS)

    Augusto, F.M.; Ghilardi Netto, T.; Subtil, L.J.; Silva, R. da

    2001-01-01

    One of the great causes of mortality between women in the world is the breast cancer. The mammograms are the method most efficient to detect some cases of cancer of breast before this to be clinically concrete. The quality of a picture system must be determined by the ability to detect tissue soft masses, cyst or tumors, but also calcifications. This detection is directly connected with the contrast obtained in these pictures. This work has for objective to develop a method for the analysis of this contrast in mammograms verifying the doses referred to these mammograms and comparing them with national and international levels of reference. (author)

  18. Measurements of incoherent light and background structure at exo-Earth detection levels in the High Contrast Imaging Testbed

    Science.gov (United States)

    Cady, Eric; Shaklan, Stuart

    2014-08-01

    A major component of the estimation and correction of starlight at very high contrasts is the creation of a dark hole: a region in the vicinity of the core of the stellar point spread function (PSF) where speckles in the PSF wings have been greatly attenuated, up to a factor of 1010 for the imaging of terrestrial exoplanets. At these very high contrasts, removing these speckles requires distinguishing between light from the stellar PSF scattered by instrument imperfections, which may be partially corrected across a broad band using deformable mirrors in the system, from light from other sources which generally may not. These other sources may be external or internal to the instrument (e.g. planets, exozodiacal light), but in either case, their distinguishing characteristic is their inability to interfere coherently with the PSF. In the following we discuss the estimation, structure, and expected origin of this incoherent" signal, primarily in the context of a series of experiments made with a linear band-limited mask in Jan-Mar 2013. We find that the incoherent" signal at moderate contrasts is largely estimation error of the coherent signal, while at very high contrasts it represents a true floor which is stable over week-timescales.

  19. Cue combination in a combined feature contrast detection and figure identification task.

    Science.gov (United States)

    Meinhardt, Günter; Persike, Malte; Mesenholl, Björn; Hagemann, Cordula

    2006-11-01

    Target figures defined by feature contrast in spatial frequency, orientation or both cues had to be detected in Gabor random fields and their shape had to be identified in a dual task paradigm. Performance improved with increasing feature contrast and was strongly correlated among both tasks. Subjects performed significantly better with combined cues than with single cues. The improvement due to cue summation was stronger than predicted by the assumption of independent feature specific mechanisms, and increased with the performance level achieved with single cues until it was limited by ceiling effects. Further, cue summation was also strongly correlated among tasks: when there was benefit due to the additional cue in feature contrast detection, there was also benefit in figure identification. For the same performance level achieved with single cues, cue summation was generally larger in figure identification than in feature contrast detection, indicating more benefit when processes of shape and surface formation are involved. Our results suggest that cue combination improves spatial form completion and figure-ground segregation in noisy environments, and therefore leads to more stable object vision.

  20. Contrast and strength of visual memory and imagery differentially affect visual perception.

    Science.gov (United States)

    Saad, Elyana; Silvanto, Juha

    2013-01-01

    Visual short-term memory (VSTM) and visual imagery have been shown to modulate visual perception. However, how the subjective experience of VSTM/imagery and its contrast modulate this process has not been investigated. We addressed this issue by asking participants to detect brief masked targets while they were engaged either in VSTM or visual imagery. Subjective experience of memory/imagery (strength scale), and the visual contrast of the memory/mental image (contrast scale) were assessed on a trial-by-trial basis. For both VSTM and imagery, contrast of the memory/mental image was positively associated with reporting target presence. Consequently, at the sensory level, both VSTM and imagery facilitated visual perception. However, subjective strength of VSTM was positively associated with visual detection whereas the opposite pattern was found for imagery. Thus the relationship between subjective strength of memory/imagery and visual detection are qualitatively different for VSTM and visual imagery, although their impact at the sensory level appears similar. Our results furthermore demonstrate that imagery and VSTM are partly dissociable processes.

  1. Contrast and strength of visual memory and imagery differentially affect visual perception.

    Directory of Open Access Journals (Sweden)

    Elyana Saad

    Full Text Available Visual short-term memory (VSTM and visual imagery have been shown to modulate visual perception. However, how the subjective experience of VSTM/imagery and its contrast modulate this process has not been investigated. We addressed this issue by asking participants to detect brief masked targets while they were engaged either in VSTM or visual imagery. Subjective experience of memory/imagery (strength scale, and the visual contrast of the memory/mental image (contrast scale were assessed on a trial-by-trial basis. For both VSTM and imagery, contrast of the memory/mental image was positively associated with reporting target presence. Consequently, at the sensory level, both VSTM and imagery facilitated visual perception. However, subjective strength of VSTM was positively associated with visual detection whereas the opposite pattern was found for imagery. Thus the relationship between subjective strength of memory/imagery and visual detection are qualitatively different for VSTM and visual imagery, although their impact at the sensory level appears similar. Our results furthermore demonstrate that imagery and VSTM are partly dissociable processes.

  2. Generalized Phase Contrast

    CERN Document Server

    Glückstad, Jesper

    2009-01-01

    Generalized Phase Contrast elevates the phase contrast technique not only to improve phase imaging but also to cross over and interface with diverse and seemingly disparate fields of contemporary optics and photonics. This book presents a comprehensive introduction to the Generalized Phase Contrast (GPC) method including an overview of the range of current and potential applications of GPC in wavefront sensing and phase imaging, structured laser illumination and image projection, optical trapping and manipulation, and optical encryption and decryption. The GPC method goes further than the restrictive assumptions of conventional Zernike phase contrast analysis and achieves an expanded range of validity beyond weak phase perturbations. The generalized analysis yields design criteria for tuning experimental parameters to achieve optimal performance in terms of accuracy, fidelity and light efficiency. Optimization can address practical issues, such as finding an optimal spatial filter for the chosen application, ...

  3. Developmental Mechanisms Underlying Improved Contrast Thresholds for Discriminations of Orientation Signals Embedded in Noise

    Directory of Open Access Journals (Sweden)

    Seong Taek eJeon

    2014-09-01

    Full Text Available We combined an external noise paradigm with an efficient procedure for obtaining contrast thresholds (Lesmes et al., 2006 in order to model developmental changes during childhood. Specifically, we measured the contrast thresholds of 5-, 7-, 9-year-olds and adults (n = 20/age in a two alternative forced-choice orientation discrimination task over a wide range of external noise levels and at three levels of accuracy. Overall, as age increased, contrast thresholds decreased over the entire range of external noise levels tested. The decrease was greatest between 5 and 7 years of age. The reduction in threshold after age 5 was greater in the high than the low external noise region, a pattern implying greater tolerance to the irrelevant background noise as children became older. To model the mechanisms underlying these developmental changes in terms of internal noise components, we adapted the original perceptual template model (Lu and Dosher, 1998 and normalized the magnitude of performance changes against the performance of 5-year-olds. The resulting model provided an excellent fit (r2 = 0.985 to the contrast thresholds at multiple levels of accuracy (60, 75, and 90% across a wide range of external noise levels. The improvements in contrast thresholds with age were best modelled by a combination of reductions in internal additive noise, reductions in internal multiplicative noise, and improvements in excluding external noise by template retuning. In line with the data, the improvement was greatest between 5 and 7 years of age, accompanied by a 39% reduction in additive noise, 71% reduction in multiplicative noise, and 45% improvement in external noise exclusion. The modelled improvements likely reflect developmental changes at the cortical level, rather than changes in front-end structural properties (Kiorpes et al., 2003.

  4. Scheme dependence of quantum gravity on de Sitter background

    Energy Technology Data Exchange (ETDEWEB)

    Kitamoto, Hiroyuki, E-mail: kitamoto@post.kek.jp [KEK Theory Center, Tsukuba, Ibaraki 305-0801 (Japan); Kitazawa, Yoshihisa, E-mail: kitazawa@post.kek.jp [KEK Theory Center, Tsukuba, Ibaraki 305-0801 (Japan); The Graduate University for Advanced Studies (Sokendai), Department of Particle and Nuclear Physics, Tsukuba, Ibaraki 305-0801 (Japan)

    2013-08-11

    We extend our investigation of the IR effects on the local dynamics of matter fields in quantum gravity. Specifically we clarify how the IR effects depend on the change of the quantization scheme: different parametrization of the metric and the matter field redefinition. Conformal invariance implies effective Lorentz invariance of the matter system in de Sitter space. An arbitrary choice of the parametrization of the metric and the matter field redefinition does not preserve the effective Lorentz invariance of the local dynamics. As for the effect of different parametrization of the metric alone, the effective Lorentz symmetry breaking term can be eliminated by shifting the background metric. In contrast, we cannot compensate the matter field redefinition dependence by such a way. The effective Lorentz invariance can be retained only when we adopt the specific matter field redefinitions where all dimensionless couplings become scale invariant at the classical level. This scheme is also singled out by unitarity as the kinetic terms are canonically normalized.

  5. Quantitative contrast-enhanced mammography for contrast medium kinetics studies

    Science.gov (United States)

    Arvanitis, C. D.; Speller, R.

    2009-10-01

    Quantitative contrast-enhanced mammography, based on a dual-energy approach, aims to extract quantitative and temporal information of the tumour enhancement after administration of iodinated vascular contrast media. Simulations using analytical expressions and optimization of critical parameters essential for the development of quantitative contrast-enhanced mammography are presented. The procedure has been experimentally evaluated using a tissue-equivalent phantom and an amorphous silicon active matrix flat panel imager. The x-ray beams were produced by a tungsten target tube and spectrally shaped using readily available materials. Measurement of iodine projected thickness in mg cm-2 has been performed. The effect of beam hardening does not introduce nonlinearities in the measurement of iodine projected thickness for values of thicknesses found in clinical investigations. However, scattered radiation introduces significant deviations from slope equal to unity when compared with the actual iodine projected thickness. Scatter correction before the analysis of the dual-energy images provides accurate iodine projected thickness measurements. At 10% of the exposure used in clinical mammography, signal-to-noise ratios in excess of 5 were achieved for iodine projected thicknesses less than 3 mg cm-2 within a 4 cm thick phantom. For the extraction of temporal information, a limited number of low-dose images were used with the phantom incorporating a flow of iodinated contrast medium. The results suggest that spatial and temporal information of iodinated contrast media can be used to indirectly measure the tumour microvessel density and determine its uptake and washout from breast tumours. The proposed method can significantly improve tumour detection in dense breasts. Its application to perform in situ x-ray biopsy and assessment of the oncolytic effect of anticancer agents is foreseeable.

  6. Consonant harmony in Nilotic: contrastive specifications and Stratal OT

    Directory of Open Access Journals (Sweden)

    Sara Mackenzie

    2016-07-01

    Full Text Available Through analyses of dental harmony in four Nilotic languages, this paper argues both for contrastive representations and for a stratal version of Optimality Theory. Dholuo, Päri, Shilluk and Anywa all have dental harmony patterns which bar the co-occurrence of dental and alveolar segments. Details of the dental harmony patterning vary between languages and are tied to contrasts in the inventory. In Anywa, harmony is non-structure-preserving and an allophonic dental nasal surfaces in harmonic forms. This pattern can be analyzed in a stratal model of OT but leads to a ranking paradox if only a single level of evaluation is used. Further support for a stratal analysis can be found in the interaction between harmony and consonant mutation processes in the four languages. In Dholuo, harmony applies at the stem level and consonant mutation results in disharmonic surface forms in morphologically complex words. In Anywa, harmony applies later, at the word level, and words formed through consonant mutation must obey the dental harmony restrictions.

  7. Modulation of visual cortical excitability by working memory: effect of luminance contrast of mental imagery

    Directory of Open Access Journals (Sweden)

    Zaira eCattaneo

    2011-02-01

    Full Text Available Although much is known about the impact of stimulus properties such as luminance contrast, spatial frequency and orientation on visually evoked neural activity, much less is known about how they modulate neural activity when they are properties of a mental image held in working memory (WM. Here we addressed this question by investigating how a parametric manipulation of an imagined stimulus attribute affects neuronal excitability in the early visual cortex. We manipulated luminance contrast, a stimulus property known to strongly affect the magnitude of neuronal responses in early visual areas. Luminance contrast modulated neuronal excitability, as assessed by the frequency of phosphenes induced by transcranial magnetic stimulation (TMS with the exact nature of this modulation depending on TMS intensity. These results point to a strong overlap in the neuronal processes underlying visual perception and mental imagery: not only does WM maintenance selectively engage neurons which are tuned to the maintained attribute (as has previously been shown, but the extent to which those neurons are activated depends on the luminance contrast (as is the case with visually-evoked responses. From a methodological viewpoint, these results suggest that assessment of visual cortical excitability using TMS is affected by the TMS intensity used to probe the neuronal population.

  8. Determination of dependence of feed intake level on functional and technological parameters of prescription mixture

    Directory of Open Access Journals (Sweden)

    Aksenova O. I.

    2016-12-01

    Full Text Available The problem of the development of pet food formulations in the conditions of information uncertainty which is characteristic of an actual business enterprise engaged in production of feed has been considered in the paper. The analysis of the literature [1–4] has shown that the main works are devoted to the extrusion of plastics and cereal products, with the temperature conditions equal to 130–200 ºC. This temperature range is not suitable for the production of pet food, and researches on this issue are virtually absent. This study is devoted to defining the functional and technological parameters of prescription mixture depending on the level of feed intake by unproductive animals; this knowledge will allow manufacturers to simplify the development of new formulations of balanced feed. Identification of this relationship has been carried out on the basis of modeling methods of mathematical statistics in Excel and Mathcad packages, as well as on the basis of fuzzy logic set theory in MatLAB package, as the construction of a complete mathematical model is complicated by absence of an explicit numerical form of the result received on the basis of sensory analysis. The research has revealed the dependence of feed intake level on functional and technological parameters of prescription mix for non-productive animals, in particular, the highest level of animal feed intake will be achieved at the following values of the main parameters: pH – 6.5; the moisture – 9 %; the protein concentration – 85 %; the particle size – 0.55 mm; the energy value – 267 kcal/100 g feed. The adequacy of the dependence for the input variables – the moisture feed and concentration of the protein component – is confirmed by the experimental investigations. This paper can be used to generate the optimal prescription composition for functional and technological characteristics of the samples in order to create balanced extruded feeds.

  9. Growth-Rate Dependent Regulation of tRNA Level and Charging in Bacillus licheniformis.

    Science.gov (United States)

    Ferro, Iolanda; Liebeton, Klaus; Ignatova, Zoya

    2017-10-13

    Cellular growth crucially depends on protein synthesis and the abundance of translational components. Among them, aminoacyl-tRNAs play a central role in biosynthesis and shape the kinetics of mRNA translation, thus influencing protein production. Here, we used microarray-based approaches to determine the charging levels and tRNA abundance of Bacillus licheniformis. We observed an interesting cross-talk among tRNA expression, charging pattern, and growth rate. For a large subset of tRNAs, we found a co-regulated and augmented expression at high growth rate. Their tRNA aminoacylation level is kept relatively constant through riboswitch-regulated expression of the cognate aminoacyl-tRNA-synthetase (AARS). We show that AARSs with putative riboswitch-controlled expression are those charging tRNAs with amino acids which disfavor cell growth when individually added to the nutrient medium. Our results suggest that the riboswitch-regulated AARS expression in B. licheniformis is a powerful mechanism not only to maintain a constant ratio of aminoacyl-tRNA independent of the growth rate but concomitantly to control the intracellular level of free amino acids. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Entropy squeezing for a two-level atom in the Jaynes-Cummings model with an intensity-depend coupling

    Institute of Scientific and Technical Information of China (English)

    李春先; 方卯发

    2003-01-01

    We study the squeezing for a two-level atom in the Jaynes-Cummings model with intensity-dependent coupling using quantum information entropy, and examine the influences of the initial state of the system on the squeezed component number and direction of the information entropy squeezing. Our results show that, the squeezed component number depends on the atomic initial distribution angle, while the squeezed direction is determined by both the phases of the atom and the field for the information entropy squeezing. Quantum information entropy is shown to be a remarkable precision measure for atomic squeezing.

  11. Entropy squeezing for a two—level atom in the Jaynes—Cummings model with an intensity—depend coupling

    Institute of Scientific and Technical Information of China (English)

    李春先; 方卯发; 等

    2003-01-01

    We study the squeezing for a two-level atom in the Jaynes-Cumings model with intensity-dependent coupling using quantum information entropy,and examine the influences of the initial state of the system on the squeezed component number and direction of the information entropy squeezing.Our results show that,the squeezed component number depends on the atomic initial distribution angle,while the squeezed direction is determined by both the phases of the atom and the field for the information entropy squeezing.Quantum information entropy is shown to be a remarkable precision measure for atomic squeezing.

  12. Contrast-induced acute kidney injury: how much contrast is safe?

    LENUS (Irish Health Repository)

    Keaney, John J

    2013-02-14

    Iodinated contrast media (CM) are used in many investigations that a patient may undergo during the course of an in-patient stay. For the vast majority of patients, exposure to CM has no sequelae; however, in a small percentage, it can result in a worsening in renal function termed contrast-induced acute kidney injury (CI-AKI). CI-AKI is one of the leading causes of in-hospital renal dysfunction. It is associated with a significant increase in morbidity and mortality as well as an increased length of hospital stay and costs. Unfortunately, the results of extensive research into pharmacological inventions to prevent CI-AKI remain disappointing. In this article, we briefly outline the pathophysiological mechanisms by which iodinated CM may cause CI-AKI and discuss the evidence for reducing CI-AKI by limiting contrast volumes. In particular, we review the data surrounding the use of contrast volume to glomerular filtration rate ratios, which can be used by clinicians to effectively lower the incidence of CI-AKI in their patients.

  13. Admittance spectroscopy or deep level transient spectroscopy: A contrasting juxtaposition

    Science.gov (United States)

    Bollmann, Joachim; Venter, Andre

    2018-04-01

    A comprehensive understanding of defects in semiconductors remains of primary importance. In this paper the effectiveness of two of the most commonly used semiconductor defect spectroscopy techniques, viz. deep level transient spectroscopy (DLTS) and admittance spectroscopy (AS) are reviewed. The analysis of defects present in commercially available SiC diodes shows that admittance spectroscopy allows the identification of deep traps with reduced measurement effort compared to deep Level Transient Spectroscopy (DLTS). Besides the N-donor, well-studied intrinsic defects were detected in these diodes. Determination of their activation energy and defect density, using the two techniques, confirm that the sensitivity of AS is comparable to that of DLTS while, due to its well defined peak shape, the spectroscopic resolution is superior. Additionally, admittance spectroscopy can analyze faster emission processes which make the study of shallow defects more practical and even that of shallow dopant levels, possible. A comparative summary for the relevant spectroscopic features of the two capacitance methods are presented.

  14. Contrasting Regulation of NO and ROS in Potato Defense-Associated Metabolism in Response to Pathogens of Different Lifestyles.

    Directory of Open Access Journals (Sweden)

    Jolanta Floryszak-Wieczorek

    Full Text Available Our research provides new insights into how the low and steady-state levels of nitric oxide (NO and reactive oxygen species (ROS in potato leaves are altered after the challenge with the hemibiotroph Phytophthora infestans or the necrotroph Botrytis cinerea, with the subsequent rapid and invader-dependent modification of defense responses with opposite effects. Mainly in the avirulent (avr P. infestans-potato system, NO well balanced with the superoxide level was tuned with a battery of SA-dependent defense genes, leading to the establishment of the hypersensitive response (HR successfully arresting the pathogen. Relatively high levels of S-nitrosoglutathione and S-nitrosothiols concentrated in the main vein of potato leaves indicated the mobile function of these compounds as a reservoir of NO bioactivity. In contrast, low-level production of NO and ROS during virulent (vr P. infestans-potato interactions might be crucial in the delayed up-regulation of PR-1 and PR-3 genes and compromised resistance to the hemibiotrophic pathogen. In turn, B. cinerea triggered huge NO overproduction and governed inhibition of superoxide production by blunting NADPH oxidase. Nevertheless, a relatively high level of H2O2 was found owing to the germin-like activity in cooperation with NO-mediated HR-like cell death in potato genotypes favorable to the necrotrophic pathogen. Moreover, B. cinerea not only provoked cell death, but also modulated the host redox milieu by boosting protein nitration, which attenuated SA production but not SA-dependent defense gene expression. Finally, based on obtained data the organismal cost of having machinery for HR in plant resistance to biotrophs is also discussed, while emphasizing new efforts to identify other components of the NO/ROS cell death pathway and improve plant protection against pathogens of different lifestyles.

  15. Contrast Media: Are There Differences in Nephrotoxicity among Contrast Media?

    Science.gov (United States)

    2014-01-01

    Iodinated contrast agents are usually classified based upon their osmolality—high, low, and isosmolar. Iodinated contrast agents are also nephrotoxic in some but not all patients resulting in loss of glomerular filtration rate. Over the past 30 years, nephrotoxicity has been linked to osmolality although the precise mechanism underlying such a link has been elusive. Improvements in our understanding of the pathogenesis of nephrotoxicity and prospective randomized clinical trials have attempted to further explore the relationship between osmolality and nephrotoxicity. In this review, the basis for our current understanding that there are little if any differences in nephrotoxic potential between low and isosmolar contrast media will be detailed using data from clinical studies. PMID:24587997

  16. Ionic and non-ionic contrast media used for contrast-enhanced computed tomography in experimental pancreatitis

    International Nuclear Information System (INIS)

    Kivisaari, L.; Nuutinen, P.; Lehtola, A.; Saari, A.; Pitkaeranta, P.; Standertskjoeld-Nordenstam, C.G.; Lempinen, M.; Schroeder, T.; Helsinki Univ. Central Hospital

    1988-01-01

    Contrast enhancement of the pancreas was studied in pigs using dynamic computed tomography in experimental oedematous and haemorrhagic/necrotizing pancreatitis during the first two minutes after injection of an intravenous bolus of non-ionic contrast medium (iohexol). The prospects of separating the two forms of the disease, known to be possible with ionic contrast media, were tested with a non-ionic contrast medium. In the oedematous form, contrast enhancement after 5 hours of the disease was significantly higher than in the haemorrhagic/necrotizing form. Contrast enhancement after 30 hours of disease tended to vary with the severity of the disease, showing that the course of oedematous pancreatitis is dynamic. Intermediate forms occur and follow-up studies are needed during the disease. A non-ionic contrast medium proved as good for separating the two forms of the disease in the early phase as were ionic contrast media. In severely ill patients, non-ionic contrast media should therefore be used. (orig.)

  17. Effects of radiographic contrast media on cellular electrophysiology in the beating heart

    Energy Technology Data Exchange (ETDEWEB)

    Wolpers, H.G.; Baller, D.; Ensink, F.B.M.; Hoeft, A.; Korb, H.; Hellige, G.

    1982-01-01

    Electrophysiological effects of intracoronarily administered contrast media have been documented in 12 thoracotomized dogs at the cellular level by use of a modified microelectrode technique. Injections (n = 63) of 4 different contrast media uniformly led to a temporary cellular hyperpolarisation of the resting potential and prolongation of the action potential. Additional experiments with intracoronary injections of several electrolyte concentrations, mainly by a local deficiency of potassium ions and an excess of sodium ions. The significance of the findings for mechanisms underlying ECG-changes and ventricular arrhythmia by radiographic contrasts media will be discussed.

  18. The effects of lithology and base level on topography in the northern alpine foreland

    Science.gov (United States)

    Baumann, Sebastian; Robl, Jörg; Prasicek, Günther; Salcher, Bernhard; Keil, Melanie

    2018-07-01

    The evolution of topography is driven by climate and tectonics, and strongly influenced by substrate properties and different base levels. The contributions of these factors may vary in space and time and are thus difficult to disentangle. Our study area, the Hausruck-Kobernaußerwald range, has a rather uniform climatic and tectonic history but is drained by rivers with different base levels and consists of contrasting sedimentary rocks, mainly due to different sedimentation environments. This makes them an ideal location to study the effects of lithology and base level on topography. To decipher the roles of these influences, we used a high-resolution digital elevation model and performed a series of morphometric analyses. Longitudinal river profiles indicate that all channels in the study area, independent from base level, bed rock and overall morphological expression, are well graded. Hypsometry shows no evidence for base level effects on the present topography, while variations in the hypsometric curves coincide with lithological differences. This is also reflected in contrasts of mean elevation and slope distributions. Lithology-dependent variations in channel concavity and catchment-wide hypsometric integrals show that lithology controls both channel incision and hillslope processes in the study area. Our results further indicate that variations in channel and catchment metrics are not linked to the prevalence of different rock types alone, but to different successions of lithological units along the channels and within the catchments. Variations in channel slope and geomorphological mapping suggest that lithology-dependent landsliding is the dominant process causing the observed large-scale landscape diversity in the Hausruck-Kobernaußerwald range.

  19. Spontaneous recovery of effects of contrast adaptation without awareness

    Directory of Open Access Journals (Sweden)

    Gaoxing eMei

    2015-09-01

    Full Text Available Prolonged exposure to a high contrast stimulus reduces the neural sensitivity to subsequent similar patterns. Recent work has disclosed that contrast adaptation is controlled by multiple mechanisms operating over differing timescales. Adaptation to high contrast for a relatively longer period can be rapidly eliminated by adaptation to a lower contrast (or meanfield in the present study. Such rapid deadaptation presumably causes a short-term mechanism to signal for a sensitivity increase, cancelling ongoing signals from long-term mechanisms. Once deadaptation ends, the short-term mechanism rapidly returns to baseline, and the slowly decaying effects in the long-term mechanisms reemerge, allowing the perceptual aftereffects to recover during continued testing. Although this spontaneous recovery effect is considered strong evidence supporting the multiple mechanisms theory, it remains controversial whether the effect is mainly driven by visual memory established during the initial longer-term adaptation period. To resolve this debate, we used a modified Continuous Flash Suppression (CFS and visual crowding paradigms to render the adapting stimuli invisible, but still observed the spontaneous recovery phenomenon. These results exclude the possibility that spontaneous recovery found in the previous work was merely the consequence of explicit visual memory. Our findings also demonstrate that contrast adaptation, even at the unconscious processing levels, is controlled by multiple mechanisms.

  20. Irradiation creep and creep rupture of titanium-modified austenitic stainless steels and their dependence on cold work level

    International Nuclear Information System (INIS)

    Garner, F.A.; Hamilton, M.L.; Eiholzer, C.R.; Toloczko, M.B.; Kumar, A.S.

    1991-11-01

    A titanium-modified austenitic type stainless steel was tested at three cold work levels to determine its creep and creep rupture properties under both thermal aging and neutron irradiation conditions. Both the thermal and irradiation creep behavior exhibit a complex non-monotonic relationship with cold work level that reflects the competition between a number of stress-sensitive and temperature-dependent microstructural processes. Increasing the degree of cold work to 30% from the conventional 20% level was detrimental to its performance, especially for applications above 550 degrees c. The 20% cold work level is preferable to the 10% level, in terms of both in-reactor creep rupture response and initial strength

  1. The changes in levels of C-P and insulin in glucose tolerance test in rats with experimental non-insulin dependent diabetes mellitus

    International Nuclear Information System (INIS)

    Liu Xinqiu; Lei Ming

    2001-01-01

    The changes in levels of C-P and insulin were investigated in the GT test in rats with non-insulin dependent diabetes mellitus. In order to establish a model of non-insulin dependent diabetes mellitus (NIDDM), the authors injected rats with small dose streptozocoi (i.v.). Two weeks after the injection, the rats developed impaired glucose tolerance (IGT). Then, they were fed with high energy diet for eight weeks to form NIDDM. The results showed that the highest peak time of C-P and insulin in NIDDM was remarkably later than that in normal subjects, the highest peak time was in two hours (P < 0.05). The data suggest that level of C-P could accurately respond to level of insulin, and this experimental non-insulin dependent diabetes mellitus model is ideal

  2. Contrast Enhancement in Poor Visibility Conditions Using Guided Filtering

    Directory of Open Access Journals (Sweden)

    D

    2013-06-01

    Full Text Available In this paper, extraction of atmospheric veil is proposed to enhance the contrast of the images captured under poor visibility conditions. The method based on guided filtering can accurately recover hidden edges, maintain structural similarity (SSIM to input image and it is effective for both color and gray level images. The proposed algorithm works without prior information about the scene and its complexity is linear function of the input image size. Experimental comparisons with state of the art algorithms demonstrate that our approach can significantly enhance the contrast and restore the visibility in fine details.

  3. Contrast enhancement of cranial lesions in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lewander, R; Bergstroem, M; Bergvall, U [Kungliga Karolinska Mediko-Kirurgiska Inst., Stockholm (Sweden)

    1978-01-01

    The time course of enhancement in apparently normal brain tissue, edema and focal lesions during 30 to 60 min after intravenous injection of vascular contrast medium was evaluated in a series of 41 pateints with differnt intracranial lesions. The attenuation of apparently normal unenhanced brain tissue varied with the level of the scan, mainly an effect of beam hardening. Different types of enhancement response are discussed in terms of a 3-compartment model. The differential diagnostic potential of contrast enhancement in the early phase needs further evaluation using instruments with short scanning time, while the late phase of enhancement must be recorded with the use of a reliable head fixation to provide reproducibility of repeat measurements.

  4. A comparison of definitions of contrast-induced nephropathy in patients with normal serum creatinine

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Khatami

    2016-01-01

    Full Text Available Contrast-induced nephropathy (CIN is the third leading cause of acute kidney injury in hospitalized patients. The prevalence of CIN is reported to range from 0% to 50%, depending not only on patient condition and the procedure used but also the definition of CIN applied. We aimed to determine the best diagnostic indicator of CIN in patients with normal serum creatinine. This study included 206 patients with normal serum creatinine who underwent coronary angiography/angioplasty. Serum creatinine level and glomerular filtration rate (GFR were measured before and on the second and fifth days after contrast administration. The incidence of CIN based on a 25% increase in serum creatinine was calculated and compared with the incidence based on a 25% decrease in GFR or an increase of at least 0.5 mg/dL in serum creatinine. Of 206 patients, 127 were male (61.7% and 79 were female (38.3%; the mean age was 59.56 ± 10.3 years. The prevalence of CIN was 30% based on a 25% increase in serum creatinine, 23% based on a 25% decrease in GFR (P <0.012 and 3.8% based on a serum creatinine increase of at least 0.5 mg/dL (P <0.0001. The serum creatinine levels remained within the normal range in the majority of patients with CIN based on the different definitions. In patients with normal serum creatinine, the absolute increase in serum creatinine may describe the prevalence of CIN more accurately than the relative increase in serum creatinine or relative decrease in GFR.

  5. Abdominal and pelvic CT: is positive enteric contrast still necessary? Results of a retrospective observational study.

    Science.gov (United States)

    Kammerer, S; Höink, A J; Wessling, J; Heinzow, H; Koch, R; Schuelke, C; Heindel, W; Buerke, B

    2015-03-01

    Evaluation of diagnostic accuracy of abdominal CT depending on the type of enteric contrast agent. Multislice CTs of 2,008 patients with different types of oral preparation (positive with barium, n = 576; neutral with water, n = 716; and no enteric contrast, n = 716) were retrospectively evaluated by two radiologists including delineation of intestinal segments and influence on diagnosis and diagnostic reliability exerted by the enteric contrast, using a three-point scale. Furthermore, diagnostic reliability of the delineation of selected enteric pathologies was noted. CT data were assigned into groups: oncology, inflammation, vascular, pathology, trauma and gastrointestinal pathology. Delineation of the bowel was clearly practicable across all segments irrespective of the type of enteric contrast, though a slight impairment was observed without enteric contrast. Although delineation of intestinal pathologies was mostly classified "clearly delimitable" more difficulties occurred without oral contrast (neutral/positive/no contrast, 0.8 %/3.8 %/6.5 %). Compared to examinations without enteric contrast, there was a significant improvement in diagnosis that was even increased regarding the reader's diagnostic reliability. Positive opacification impaired detection of mucosal enhancement or intestinal bleeding. Water can replace positive enteric contrast agents in abdominal CTs. However, selected clinical questions require individual enteric contrast preparations. Pathology detection is noticeably impaired without any enteric contrast.

  6. Hepatobiliary contrast agents for contrast-enhanced MRI of the liver: properties, clinical development and applications

    International Nuclear Information System (INIS)

    Reimer, Peter; Schneider, Guenter; Schima, Wolfgang

    2004-01-01

    Hepatobiliary contrast agents with uptake into hepatocytes followed by variable biliary excretion represent a unique class of cell-specific MR contrast agents. Two hepatobiliary contrast agents, mangafodipir trisodium and gadobenate dimeglumine, are already clinically approved. A third hepatobiliary contrast agent, Gd-EOB-DTPA, is under consideration. The purpose of this review is to provide an overview on the properties, clinical development and application of these three hepatobiliary contrast agents. Bolus injectable paramagnetic hepatobiliary contrast agents combine established features of extracellular agents with the advantages of hepatocyte specificity. The detection and characterisation of focal liver disease appears to be improved compared to unenhanced MRI, MRI with unspecific contrast agents and contrast-enhanced CT. To decrease the total time spent by a patient in the MR scanner, it is advisable to administer the agent immediately after acquisition of unenhanced T1-w MRI. After infusion or bolus injection (with dynamic FS-T1-w 2D or 3D GRE) of the contrast agent, moderately and heavily T2w images are acquired. Post-contrast T1-w MRI is started upon completion of T2-w MRI for mangafodipir trisodium and Gd-EOB-DTPA as early as 20 min following injection, while gadobenate dimeglumine scans are obtained >60 min following injection. Post-contrast acquisition techniques with near isotropic 3D pulse sequences with fat saturation parallel the technical progress made by MSCT combined with an unparalleled improvement in tumour-liver contrast. The individual decision that hepatobiliary contrast agent one uses is partly based on personal preferences. No comparative studies have been conducted comparing the advantages or disadvantages of all three agents directly against each other. (orig.)

  7. Benzene metabolite levels in blood and bone marrow of B6C3F{sub 1} mice after low-level exposure

    Energy Technology Data Exchange (ETDEWEB)

    Bechtold, W.E.; Strunk, M.R.; Thornton-Manning, J.R. [and others

    1995-12-01

    Studies at the Inhalation Toxicology Research Institute (ITRI) have explored the species-specific uptake and metabolism of benzene. Results have shown that metabolism is dependent on both dose and route of administration. Of particular interest were shifts in the major metabolic pathways as a function of exposure concentration. In these studies, B6C3F{sub 1} mice were exposed to increasing levels of benzene by either gavage or inhalation. As benzene internal dose increased, the relative amounts of muconic acid and hydroquinone decreased. In contrast, the relative amount of catechol increased with increasing exposure. These results show that the relative levels of toxic metabolites are a function of exposure level. Based on these results and assuming a linear relationship between exposure concentration and levels of bone marrow metabolites, it would be difficult to detect an elevation of any phenolic metabolites above background after occupational exposures to the OSHA Permissible Exposure Limit of 1 ppm benzene.

  8. Mamografia Espectral de Contraste

    OpenAIRE

    Martins, Inês Santiago; Pereira, Inês; Pacheco, Hugo Pisco; Moutinho, Leonor

    2014-01-01

    A mamografia de contraste é uma aplicação recente possível com a mamografia digital directa, que utiliza contraste iodado endovenoso tendo como princípio a neovascularização induzida no cancro da mama, permitindo obter informação morfológica e funcional. Na mamografia espectral de contraste realiza-se uma aquisição simultânea com alta e baixa energia para cada incidência após administração de contraste iodado endovenoso. É depois feita uma imagem recombinada em que são realçadas as áreas que ...

  9. Contrast enhanced cartilage imaging: Comparison of ionic and non-ionic contrast agents

    International Nuclear Information System (INIS)

    Wiener, Edzard; Woertler, Klaus; Weirich, Gregor; Rummeny, Ernst J.; Settles, Marcus

    2007-01-01

    Our objective was to compare relaxation effects, dynamics and spatial distributions of ionic and non-ionic contrast agents in articular cartilage at concentrations typically used for direct MR arthrography at 1.5 T. Dynamic MR-studies over 11 h were performed in 15 bovine patella specimens. For each of the contrast agents gadopentetate dimeglumine, gadobenate dimeglumine, gadoteridol and mangafodipir trinatrium three patellae were placed in 2.5 mmol/L contrast solution. Simultaneous measurements of T 1 and T 2 were performed every 30 min using a high-spatial-resolution 'MIX'-sequence. T 1 , T 2 and ΔR 1 , ΔR 2 profile plots across cartilage thickness were calculated to demonstrate the spatial and temporal distributions. The charge is one of the main factors which controls the amount of the contrast media diffusing into intact cartilage, but independent of the charge, the spatial distribution across cartilage thickness remains highly inhomogeneous even after 11 h of diffusion. The absolute ΔR 2 -effect in cartilage is at least as large as the ΔR 1 -effect for all contrast agents. Maximum changes were 5-12 s -1 for ΔR 1 and 8-15 s -1 for ΔR 2 . This study indicates that for morphologically intact cartilage only the amount of contrast agents within cartilage is determined by the charge but not the spatial distribution across cartilage thickness. In addition, ΔR 2 can be considered for quantification of contrast agent concentrations, since it is of the same magnitude and less time consuming to measure than ΔR 1

  10. Water level affects availability of optimal feeding habitats for threatened migratory waterbirds

    DEFF Research Database (Denmark)

    Aharon-Rotman, Yaara; McEvoy, John; Zheng Zhaoju

    2017-01-01

    within the lake. Changing the natural hydrological system will affect waterbirds dependent on water level changes for food availability and accessibility. We tracked two goose species with different feeding behaviors (greater white-fronted geese Anser albifrons [grazing species] and swan geese Anser......Extensive ephemeral wetlands at Poyang Lake, created by dramatic seasonal changes in water level, constitute the main wintering site for migratory Anatidae in China. Reductions in wetland area during the last 15years have led to proposals to build a Poyang Dam to retain high winter water levels...... cygnoides [tuber-feeding species]) during two winters with contrasting water levels (continuous recession in 2015; sustained high water in 2016, similar to those predicted post-Poyang Dam), investigating the effects of water level change on their habitat selection based on vegetation and elevation. In 2015...

  11. Contrast-induced nephropathy: risks, pathogenetic, prevention

    International Nuclear Information System (INIS)

    Paskalev, D.; Balev, B.

    2006-01-01

    Full text: The aim of the presentation is to review the contrast induced nephropathy ? nature, mechanisms of development, risk factors. Summary of the most important ways of prevention, diagnostics and treatment. The definition of CIN according the European Association of Urogenital Radiology is: 'A condition, in which renal function is impaired (elevation of serum creatinine with more than 25% or 44 μmol/l above the initial level) due to intravasal application of contrast media (CM) within 3 days following the application and when no other etiology factors are present'. We summarize the main risk factors of developing CIN - renal failure, diabetic nephropathy, dehydration, congestive heart failure, high blood pressure, age above 70 yrs, nephrotoxic medicines. The most effective ways of preventing CIN are the good hydratation of the patients and the usage of low-osmolar or iso-osmolar CM. Therapeutic treatment is with no proven preventive effect and currently is not routinely recommended. An early hem dialysis does not decrease the risk level of CIN development in patients with chronic renal failure (CRF). In such patients complete elimination of CM is achieved only after several hem dialyses. Hem filtration reliably decreases the risk of CIN in CRF patients, but is expensive and not widely available. We present a case from our hospital of a patient with diabetic nephropathy, who developed CIN following a coronary angiography

  12. Ck2-Dependent Phosphorylation Is Required to Maintain Pax7 Protein Levels in Proliferating Muscle Progenitors.

    Directory of Open Access Journals (Sweden)

    Natalia González

    Full Text Available Skeletal muscle regeneration and long term maintenance is directly link to the balance between self-renewal and differentiation of resident adult stem cells known as satellite cells. In turn, satellite cell fate is influenced by a functional interaction between the transcription factor Pax7 and members of the MyoD family of muscle regulatory factors. Thus, changes in the Pax7-to-MyoD protein ratio may act as a molecular rheostat fine-tuning acquisition of lineage identity while preventing precocious terminal differentiation. Pax7 is expressed in quiescent and proliferating satellite cells, while its levels decrease sharply in differentiating progenitors Pax7 is maintained in cells (reacquiring quiescence. While the mechanisms regulating Pax7 levels based on differentiation status are not well understood, we have recently described that Pax7 levels are directly regulated by the ubiquitin-ligase Nedd4, thus promoting proteasome-dependent Pax7 degradation in differentiating satellite cells. Here we show that Pax7 levels are maintained in proliferating muscle progenitors by a mechanism involving casein kinase 2-dependent Pax7 phosphorylation at S201. Point mutations preventing S201 phosphorylation or casein kinase 2 inhibition result in decreased Pax7 protein in proliferating muscle progenitors. Accordingly, this correlates directly with increased Pax7 ubiquitination. Finally, Pax7 down regulation induced by casein kinase 2 inhibition results in precocious myogenic induction, indicating early commitment to terminal differentiation. These observations highlight the critical role of post translational regulation of Pax7 as a molecular switch controlling muscle progenitor fate.

  13. Growth temperature dependence of Si doping efficiency and compensating deep level defect incorporation in Al0.7Ga0.3N

    International Nuclear Information System (INIS)

    Armstrong, Andrew M.; Moseley, Michael W.; Allerman, Andrew A.; Crawford, Mary H.; Wierer, Jonathan J.

    2015-01-01

    The growth temperature dependence of Si doping efficiency and deep level defect formation was investigated for n-type Al 0.7 Ga 0.3 N. It was observed that dopant compensation was greatly reduced with reduced growth temperature. Deep level optical spectroscopy and lighted capacitance-voltage were used to understand the role of acceptor-like deep level defects on doping efficiency. Deep level defects were observed at 2.34 eV, 3.56 eV, and 4.74 eV below the conduction band minimum. The latter two deep levels were identified as the major compensators because the reduction in their concentrations at reduced growth temperature correlated closely with the concomitant increase in free electron concentration. Possible mechanisms for the strong growth temperature dependence of deep level formation are considered, including thermodynamically driven compensating defect formation that can arise for a semiconductor with very large band gap energy, such as Al 0.7 Ga 0.3 N

  14. Dependent Human Error Probability Assessment

    International Nuclear Information System (INIS)

    Simic, Z.; Mikulicic, V.; Vukovic, I.

    2006-01-01

    This paper presents an assessment of the dependence between dynamic operator actions modeled in a Nuclear Power Plant (NPP) PRA and estimate the associated impact on Core damage frequency (CDF). This assessment was done improve HEP dependencies implementation inside existing PRA. All of the dynamic operator actions modeled in the NPP PRA are included in this assessment. Determining the level of HEP dependence and the associated influence on CDF are the major steps of this assessment. A decision on how to apply the results, i.e., should permanent HEP model changes be made, is based on the resulting relative CDF increase. Some CDF increase was selected as a threshold based on the NPP base CDF value and acceptance guidelines from the Regulatory Guide 1.174. HEP dependence resulting in a CDF increase of > 5E-07 would be considered potential candidates for specific incorporation into the baseline model. The approach used to judge the level of dependence between operator actions is based on dependency level categories and conditional probabilities developed in the Handbook of Human Reliability Analysis with Emphasis on Nuclear Power Plant Applications NUREG/CR-1278. To simplify the process, NUREG/CR-1278 identifies five levels of dependence: ZD (zero dependence), LD (low dependence), MD (moderate dependence), HD (high dependence), and CD (complete dependence). NUREG/CR-1278 also identifies several qualitative factors that could be involved in determining the level of dependence. Based on the NUREG/CR-1278 information, Time, Function, and Spatial attributes were judged to be the most important considerations when determining the level of dependence between operator actions within an accident sequence. These attributes were used to develop qualitative criteria (rules) that were used to judge the level of dependence (CD, HD, MD, LD, ZD) between the operator actions. After the level of dependence between the various HEPs is judged, quantitative values associated with the

  15. Wood-energy: success depends on the price of fossil energies and on the carbon tax level

    International Nuclear Information System (INIS)

    Defaye, Serge; Maindrault, Marc

    2016-01-01

    Illustrated by several graphs indicating the structure of fossil energy prices, the comparison between domestic fuel and wood-energy for public network exploitation, the levels of fossil prices and carbon tax for non-subsidised projects, this article analyses the development of biomass (and more particularly wood-energy), the success of which depends on the price of fossil energies and on the carbon tax level. It outlines the differences of price-building elements between fossil and renewable heat, that subsidies are necessary if reference prices are low. It discusses the influence of carbon tax level and of fossil prices. It finally identifies conditions to be met (reduction of fossil energy supply and therefore higher fossil prices, introduction of a carbon tax) to reach COP objectives

  16. Ultrasound contrast agent imaging: Real-time imaging of the superharmonics

    Energy Technology Data Exchange (ETDEWEB)

    Peruzzini, D.; Viti, J. [MSD lab, Department of Information Engineering, Univ of Florence, Via S.Marta, 3, 50139 Firenze (Italy); Erasmus MC, ’s-Gravendijkwal 230, Faculty Building, Ee 2302, 3015 CE Rotterdam (Netherlands); Tortoli, P. [MSD lab, Department of Information Engineering, Univ of Florence, Via S.Marta, 3, 50139 Firenze (Italy); Verweij, M. D. [Acoustical Wavefield Imaging, ImPhys, Delft Univ Technology, van der Waalsweg 8, 2628 CH Delft (Netherlands); Jong, N. de; Vos, H. J., E-mail: h.vos@erasmusmc.nl [Erasmus MC, ’s-Gravendijkwal 230, Faculty Building, Ee 2302, 3015 CE Rotterdam (Netherlands); Acoustical Wavefield Imaging, ImPhys, Delft Univ Technology, van der Waalsweg 8, 2628 CH Delft (Netherlands)

    2015-10-28

    Currently, in medical ultrasound contrast agent (UCA) imaging the second harmonic scattering of the microbubbles is regularly used. This scattering is in competition with the signal that is caused by nonlinear wave propagation in tissue. It was reported that UCA imaging based on the third or higher harmonics, i.e. “superharmonic” imaging, shows better contrast. However, the superharmonic scattering has a lower signal level compared to e.g. second harmonic signals. This study investigates the contrast-to-tissue ratio (CTR) and signal to noise ratio (SNR) of superharmonic UCA scattering in a tissue/vessel mimicking phantom using a real-time clinical scanner. Numerical simulations were performed to estimate the level of harmonics generated by the microbubbles. Data were acquired with a custom built dual-frequency cardiac phased array probe. Fundamental real-time images were produced while beam formed radiofrequency (RF) data was stored for further offline processing. The phantom consisted of a cavity filled with UCA surrounded by tissue mimicking material. The acoustic pressure in the cavity of the phantom was 110 kPa (MI = 0.11) ensuring non-destructivity of UCA. After processing of the acquired data from the phantom, the UCA-filled cavity could be clearly observed in the images, while tissue signals were suppressed at or below the noise floor. The measured CTR values were 36 dB, >38 dB, and >32 dB, for the second, third, and fourth harmonic respectively, which were in agreement with those reported earlier for preliminary contrast superharmonic imaging. The single frame SNR values (in which ‘signal’ denotes the signal level from the UCA area) were 23 dB, 18 dB, and 11 dB, respectively. This indicates that noise, and not the tissue signal, is the limiting factor for the UCA detection when using the superharmonics in nondestructive mode.

  17. Functional interactions of HIV-infection and methamphetamine dependence during motor programming.

    Science.gov (United States)

    Archibald, Sarah L; Jacobson, Mark W; Fennema-Notestine, Christine; Ogasawara, Miki; Woods, Steven P; Letendre, Scott; Grant, Igor; Jernigan, Terry L

    2012-04-30

    Methamphetamine (METH) dependence is frequently comorbid with HIV infection and both have been linked to alterations of brain structure and function. In a previous study, we showed that the brain volume loss characteristic of HIV infection contrasts with METH-related volume increases in striatum and parietal cortex, suggesting distinct neurobiological responses to HIV and METH (Jernigan et al., 2005). Functional magnetic resonance imaging (fMRI) has the potential to reveal functional interactions between the effects of HIV and METH. In the present study, 50 participants were studied in four groups: an HIV+ group, a recently METH-dependent group, a dually affected group, and a group of unaffected community comparison subjects. An fMRI paradigm consisting of motor sequencing tasks of varying levels of complexity was administered to examine blood oxygenation level dependent (BOLD) changes. Within all groups, activity increased significantly with increasing task complexity in large clusters within sensorimotor and parietal cortex, basal ganglia, cerebellum, and cingulate. The task complexity effect was regressed on HIV status, METH status, and the HIV×METH interaction term in a simultaneous multiple regression. HIV was associated with less complexity-related activation in striatum, whereas METH was associated with less complexity-related activation in parietal regions. Significant interaction effects were observed in both cortical and subcortical regions; and, contrary to expectations, the complexity-related activation was less aberrant in dually affected than in single risk participants, in spite of comparable levels of neurocognitive impairment among the clinical groups. Thus, HIV and METH dependence, perhaps through their effects on dopaminergic systems, may have opposing functional effects on neural circuits involved in motor programming. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  18. Stress leads to contrasting effects on the levels of brain derived neurotrophic factor in the hippocampus and amygdala.

    Directory of Open Access Journals (Sweden)

    Harini Lakshminarasimhan

    Full Text Available Recent findings on stress induced structural plasticity in rodents have identified important differences between the hippocampus and amygdala. The same chronic immobilization stress (CIS, 2 h/day causes growth of dendrites and spines in the basolateral amygdala (BLA, but dendritic atrophy in hippocampal area CA3. CIS induced morphological changes also differ in their temporal longevity--BLA hypertrophy, unlike CA3 atrophy, persists even after 21 days of stress-free recovery. Furthermore, a single session of acute immobilization stress (AIS, 2 h leads to a significant increase in spine density 10 days, but not 1 day, later in the BLA. However, little is known about the molecular correlates of the differential effects of chronic and acute stress. Because BDNF is known to be a key regulator of dendritic architecture and spines, we investigated if the levels of BDNF expression reflect the divergent effects of stress on the hippocampus and amygdala. CIS reduces BDNF in area CA3, while it increases it in the BLA of male Wistar rats. CIS-induced increase in BDNF expression lasts for at least 21 days after the end of CIS in the BLA. But CIS-induced decrease in area CA3 BDNF levels, reverses to normal levels within the same period. Finally, BDNF is up regulated in the BLA 1 day after AIS and this increase persists even 10 days later. In contrast, AIS fails to elicit any significant change in area CA3 at either time points. Together, these findings demonstrate that both acute and chronic stress trigger opposite effects on BDNF levels in the BLA versus area CA3, and these divergent changes also follow distinct temporal profiles. These results point to a role for BDNF in stress-induced structural plasticity across both hippocampus and amygdala, two brain areas that have also been implicated in the cognitive and affective symptoms of stress-related psychiatric disorders.

  19. Feature and Contrast Enhancement of Mammographic Image Based on Multiscale Analysis and Morphology

    Directory of Open Access Journals (Sweden)

    Shibin Wu

    2013-01-01

    Full Text Available A new algorithm for feature and contrast enhancement of mammographic images is proposed in this paper. The approach bases on multiscale transform and mathematical morphology. First of all, the Laplacian Gaussian pyramid operator is applied to transform the mammography into different scale subband images. In addition, the detail or high frequency subimages are equalized by contrast limited adaptive histogram equalization (CLAHE and low-pass subimages are processed by mathematical morphology. Finally, the enhanced image of feature and contrast is reconstructed from the Laplacian Gaussian pyramid coefficients modified at one or more levels by contrast limited adaptive histogram equalization and mathematical morphology, respectively. The enhanced image is processed by global nonlinear operator. The experimental results show that the presented algorithm is effective for feature and contrast enhancement of mammogram. The performance evaluation of the proposed algorithm is measured by contrast evaluation criterion for image, signal-noise-ratio (SNR, and contrast improvement index (CII.

  20. 3D printing X-Ray Quality Control Phantoms. A Low Contrast Paradigm

    Science.gov (United States)

    Kapetanakis, I.; Fountos, G.; Michail, C.; Valais, I.; Kalyvas, N.

    2017-11-01

    Current 3D printing technology products may be usable in various biomedical applications. Such an application is the creation of X-ray quality control phantoms. In this work a self-assembled 3D printer (geeetech i3) was used for the design of a simple low contrast phantom. The printing material was Polylactic Acid (PLA) (100% printing density). Low contrast scheme was achieved by creating air-holes with different diameters and thicknesses, ranging from 1mm to 9mm. The phantom was irradiated at a Philips Diagnost 93 fluoroscopic installation at 40kV-70kV with the semi-automatic mode. The images were recorded with an Agfa cr30-x CR system and assessed with ImageJ software. The best contrast value observed was approximately 33%. In low contrast detectability check it was found that the 1mm diameter hole was always visible, for thickness larger or equal to 4mm. A reason for not being able to distinguish 1mm in smaller thicknesses might be the presence of printing patterns on the final image, which increased the structure noise. In conclusion the construction of a contrast resolution phantom with a 3D printer is feasible. The quality of the final product depends upon the printer accuracy and the material characteristics.

  1. Comparing Theories of Reference-Dependent Choice

    Science.gov (United States)

    Bhatia, Sudeep

    2017-01-01

    Preferences are influenced by the presence or absence of salient choice options, known as reference points. This behavioral tendency is traditionally attributed to the loss aversion and diminishing sensitivity assumptions of prospect theory. In contrast, some psychological research suggests that reference dependence is caused by attentional biases…

  2. Weight-adapted iodinated contrast media administration in abdomino-pelvic CT: Can image quality be maintained?

    Science.gov (United States)

    Perrin, E; Jackson, M; Grant, R; Lloyd, C; Chinaka, F; Goh, V

    2018-02-01

    In many centres, a fixed method of contrast-media administration is used for CT regardless of patient body habitus. The aim of this trial was to assess contrast enhancement of the aorta, portal vein, liver and spleen during abdomino-pelvic CT imaging using a weight-adapted contrast media protocol compared to the current fixed dose method. Thirty-nine oncology patients, who had previously undergone CT abdomino-pelvic imaging at the institution using a fixed contrast media dose, were prospectively imaged using a weight-adapted contrast media dose (1.4 ml/kg). The two sets of images were assessed for contrast enhancement levels (HU) at locations in the liver, aorta, portal vein and spleen during portal-venous enhancement phase. The t-test was used to compare the difference in results using a non-inferiority margin of 10 HU. When the contrast dose was tailored to patient weight, contrast enhancement levels were shown to be non-inferior to the fixed dose method (liver p contrast dose reduction of 165 ml using the weight-adapted method compared to the fixed dose method, with a mean cost per patient of £6.81 and £7.19 respectively. Using a weight-adapted method of contrast media administration was shown to be non-inferior to a fixed dose method of contrast media administration. Patients weighing 76 kg, or less, received a lower contrast dose which may have associated cost savings. A weight-adapted contrast media protocol should be implemented for portal-venous phase abdomino-pelvic CT for oncology patients with adequate renal function (>70 ml/min/1.73 m 2 ). Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  3. Contrasting population-level responses to Pleistocene climatic oscillations in an alpine bat revealed by complete mitochondrial genomes and evolutionary history inference

    DEFF Research Database (Denmark)

    Alberdi, Antton; Gilbert, M. Thomas P; Razgour, Orly

    2015-01-01

    Aim: We used an integrative approach to reconstruct the evolutionary history of the alpine long-eared bat, Plecotus macrobullaris, to test whether the variable effects of Pleistocene climatic oscillations across geographical regions led to contrasting population-level demographic histories within...... a single species. Location: The Western Palaearctic. Methods: We sequenced the complete mitochondrial genomes of 57 individuals from across the distribution of the species. The analysis integrated ecological niche modelling (ENM), approximate Bayesian computation (ABC), measures of genetic diversity...... and Bayesian phylogenetic methods. Results: We identified two deep lineages: a western lineage, restricted to the Pyrenees and the Alps, and an eastern lineage, which expanded across the mountain ranges east of the Dinarides (Croatia). ENM projections of past conditions predicted that climatic suitability...

  4. Readability of alphanumeric characters having various contrast levels as a function of age and illumination mode.

    Science.gov (United States)

    1977-07-01

    Readability data of alphanumeric characters that vary in figure-to- ground contrast ratio were obtained from 36 subjects; 12 subjects were placed in each of three age groups (20-25 yr, 40-45 yr, and 60-65 yr). Minimum illuminance required to identify...

  5. The Effect of Hyperuricemia on the Rate of Contrast-Induced Nephropathy in Patients with Coronary Angiography

    Directory of Open Access Journals (Sweden)

    Hossein Vakili

    2016-10-01

    Full Text Available Introduction: There is little information about the relationship between hyperuricemia and contrast induced nephropathy. The present study aimed to evaluate the relationship between hyperuricemia and contrast induced nephropathy among patients, who had undergone coronary angiography.Methods: In the current study, 200 consecutive patients with coronary artery disease, who underwent coronary angiography in Modarres hospital, were enrolled. According to the available data, the upper limit normal level of uric acid was defined as 7 mg/dl in males and 6.5 mg/dl in females. By increasing level of serum creatinine to 0.5 mg/dl (or 25% enhancement from basic level of creatinine during 48 hours of introduction of contrast agent, diagnosis of Contrast Induced Nephropathy (CIN was established. The relationship between hyperuricemia and CIN was then assessed.Results: There is a significant difference between normouricemic patients and hyperuricemic patients, in aspect of weight (P = 0.011 and uric acid (P = 0.001; however, other quantitative and qualitative variables including age, volume of contract agent, creatinine level after angiography, hemoglobin level, gender, arterial access type, number of involved vessels, were insignificant between the two groups (P > 0.05. Moreover, as an essential finding, CIN was shown in 9% of normouricemic patients and 10% of hyperuricemic  patients with no significant difference between the two groups (P = 0.6.Conclusions: Our study suggests that hyperuricemia may not significantly increase the rate of the contrast-induced nephropathy in patients, who had undergone angiography

  6. Abdominal and pelvic CT: is positive enteric contrast still necessary? Results of a retrospective observational study

    Energy Technology Data Exchange (ETDEWEB)

    Kammerer, S.; Hoeink, A.J.; Wessling, J.; Schuelke, C.; Heindel, W.; Buerke, B. [University Hospital Muenster, Department of Clinical Radiology, Muenster (Germany); Heinzow, H. [University Hospital Muenster, Department of Gastroenterology and Metabolic Diseases, Muenster (Germany); Koch, R. [University Muenster, Institute of Biostatistics and Clinical Research, Muenster (Germany)

    2014-10-15

    Evaluation of diagnostic accuracy of abdominal CT depending on the type of enteric contrast agent. Multislice CTs of 2,008 patients with different types of oral preparation (positive with barium, n = 576; neutral with water, n = 716; and no enteric contrast, n = 716) were retrospectively evaluated by two radiologists including delineation of intestinal segments and influence on diagnosis and diagnostic reliability exerted by the enteric contrast, using a three-point scale. Furthermore, diagnostic reliability of the delineation of selected enteric pathologies was noted. CT data were assigned into groups: oncology, inflammation, vascular, pathology, trauma and gastrointestinal pathology. Delineation of the bowel was clearly practicable across all segments irrespective of the type of enteric contrast, though a slight impairment was observed without enteric contrast. Although delineation of intestinal pathologies was mostly classified ''clearly delimitable'' more difficulties occurred without oral contrast (neutral/positive/no contrast, 0.8 %/3.8 %/6.5 %). Compared to examinations without enteric contrast, there was a significant improvement in diagnosis that was even increased regarding the reader's diagnostic reliability. Positive opacification impaired detection of mucosal enhancement or intestinal bleeding. Water can replace positive enteric contrast agents in abdominal CTs. However, selected clinical questions require individual enteric contrast preparations. Pathology detection is noticeably impaired without any enteric contrast. circle Neutral oral contrast ensures an equivalent delineation of the bowel. (orig.)

  7. Concept of contrast transfer function for edge illumination x-ray phase-contrast imaging and its comparison with the free-space propagation technique.

    Science.gov (United States)

    Diemoz, Paul C; Vittoria, Fabio A; Olivo, Alessandro

    2016-05-16

    Previous studies on edge illumination (EI) X-ray phase-contrast imaging (XPCi) have investigated the nature and amplitude of the signal provided by this technique. However, the response of the imaging system to different object spatial frequencies was never explicitly considered and studied. This is required in order to predict the performance of a given EI setup for different classes of objects. To this scope, in the present work we derive analytical expressions for the contrast transfer function of an EI imaging system, using the approximation of near-field regime, and study its dependence upon the main experimental parameters. We then exploit these results to compare the frequency response of an EI system with respect of that of a free-space propagation XPCi one. The results achieved in this work can be useful for predicting the signals obtainable for different types of objects and also as a basis for new retrieval methods.

  8. Light Signaling-Dependent Regulation of Photoinhibition and Photoprotection in Tomato.

    Science.gov (United States)

    Wang, Feng; Wu, Nan; Zhang, Luyue; Ahammed, Golam Jalal; Chen, Xiaoxiao; Xiang, Xun; Zhou, Jie; Xia, Xiaojian; Shi, Kai; Yu, Jingquan; Foyer, Christine H; Zhou, Yanhong

    2018-02-01

    Photoreceptor-mediated light signaling plays a critical role in plant growth, development, and stress responses but its contribution to the spatial regulation of photoinhibition and photoprotection within the canopy remains unclear. Here, we show that low-red/far-red ( L - R / FR ) ratio light conditions significantly alleviate PSII and PSI photoinhibition in the shade leaves of tomato ( Solanum lycopersicum ) plants. This protection is accompanied by a phytochrome A-dependent induction of LONG HYPOCOTYL5 (HY5). HY5 binds to the promoter of ABA INSENSITIVE 5 ( ABI5 ), triggering RESPIRATORY BURST OXIDASE HOMOLOG1 ( RBOH1 )-dependent H 2 O 2 production in the apoplast. Decreased levels of HY5 , ABI5 , and RBOH1 transcripts increased cold-induced photoinhibition and abolished L - R / FR -induced alleviation of photoinhibition. L - R / FR illumination induced nonphotochemical quenching (NPQ) of chlorophyll a fluorescence and increased the activities of Foyer-Halliwell-Asada cycle enzymes and cyclic electron flux (CEF) around PSI. In contrast, decreased HY5 , ABI5 , and RBOH1 transcript levels abolished the positive effect of L - R / FR on photoprotection. Loss of PROTON GRADIENT REGULATION5 -dependent CEF led to increased photoinhibition and attenuated L - R / FR -dependent NPQ. These data demonstrate that HY5 is an important hub in the cross talk between light and cold response pathways, integrating ABA and reactive oxygen species signaling, leading to the attenuation of photoinhibition by enhanced induction of photoprotection in shade leaves. © 2018 American Society of Plant Biologists. All Rights Reserved.

  9. Understanding the exposure-time effect on speckle contrast measurements for laser displays

    Science.gov (United States)

    Suzuki, Koji; Kubota, Shigeo

    2018-02-01

    To evaluate the influence of exposure time on speckle noise for laser displays, speckle contrast measurement method was developed observable at a human eye response time using a high-sensitivity camera which has a signal multiplying function. The nonlinearity of camera light sensitivity was calibrated to measure accurate speckle contrasts, and the measuring lower limit noise of speckle contrast was improved by applying spatial-frequency low pass filter to the captured images. Three commercially available laser displays were measured over a wide range of exposure times from tens of milliseconds to several seconds without adjusting the brightness of laser displays. The speckle contrast of raster-scanned mobile projector without any speckle-reduction device was nearly constant over various exposure times. On the contrary to this, in full-frame projection type laser displays equipped with a temporally-averaging speckle-reduction device, some of their speckle contrasts close to the lower limits noise were slightly increased at the shorter exposure time due to the noise. As a result, the exposure-time effect of speckle contrast could not be observed in our measurements, although it is more reasonable to think that the speckle contrasts of laser displays, which are equipped with the temporally-averaging speckle-reduction device, are dependent on the exposure time. This discrepancy may be attributed to the underestimation of temporal averaging factor. We expected that this method is useful for evaluating various laser displays and clarify the relationship between the speckle noise and the exposure time for a further verification of speckle reduction.

  10. 4D phase contrast flow imaging for in-stent flow visualization and assessment of stent patency in peripheral vascular stents--a phantom study.

    Science.gov (United States)

    Bunck, Alexander C; Jüttner, Alena; Kröger, Jan Robert; Burg, Matthias C; Kugel, Harald; Niederstadt, Thomas; Tiemann, Klaus; Schnackenburg, Bernhard; Crelier, Gerard R; Heindel, Walter; Maintz, David

    2012-09-01

    4D phase contrast flow imaging is increasingly used to study the hemodynamics in various vascular territories and pathologies. The aim of this study was to assess the feasibility and validity of MRI based 4D phase contrast flow imaging for the evaluation of in-stent blood flow in 17 commonly used peripheral stents. 17 different peripheral stents were implanted into a MR compatible flow phantom. In-stent visibility, maximal velocity and flow visualization were assessed and estimates of in-stent patency obtained from 4D phase contrast flow data sets were compared to a conventional 3D contrast-enhanced magnetic resonance angiography (CE-MRA) as well as 2D PC flow measurements. In all but 3 of the tested stents time-resolved 3D particle traces could be visualized inside the stent lumen. Quality of 4D flow visualization and CE-MRA images depended on stent type and stent orientation relative to the magnetic field. Compared to the visible lumen area determined by 3D CE-MRA, estimates of lumen patency derived from 4D flow measurements were significantly higher and less dependent on stent type. A higher number of stents could be assessed for in-stent patency by 4D phase contrast flow imaging (n=14) than by 2D phase contrast flow imaging (n=10). 4D phase contrast flow imaging in peripheral vascular stents is feasible and appears advantageous over conventional 3D contrast-enhanced MR angiography and 2D phase contrast flow imaging. It allows for in-stent flow visualization and flow quantification with varying quality depending on stent type. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  11. Assessment of image display of contrast enhanced T1W images with fat suppression

    International Nuclear Information System (INIS)

    Miyazaki, Isao; Ishizaki, Keiko; Kobayashi, Kuninori; Katou, Masanobu

    2006-01-01

    The effects of imaging conditions and measures for their improvement were examined with regard to recognition of the effects of contrast on images when T 1 -weighted imaging with selective fat suppression was applied. Luminance at the target region was examined before and after contrast imaging using phantoms assuming pre- and post-imaging conditions. A clinical examination was performed on tumors revealed by breast examination, including those surrounded by mammary gland and by fat tissue. When fat suppression was used and imaging contrast was enhanced, the luminance level of fat tumors with the same structure as the prepared phantoms appeared to be high both before and after contrast imaging, and the effects of contrast were not distinguishable. This observation is attributable to the fact that the imaging conditions before and after contrast imaging were substantially different. To make a comparison between pre- and post-contrast images, it is considered necessary to perform imaging with fixed receiver gain and to apply the same imaging method for pre- and post-contrast images by adjusting post-contrast imaging conditions to those of pre-contrast imaging. (author)

  12. The structure of dodecagonal (Ta,V){sub 1.6}Te imaged by phase-contrast scanning transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Krumeich, F., E-mail: krumeich@inorg.chem.ethz.ch [Laboratory of Inorganic Chemistry, ETH Zurich, Wolfgang-Pauli-Strasse 10, 8093 Zurich (Switzerland); Mueller, E.; Wepf, R.A. [Electron Microscopy ETH Zurich (EMEZ), Wolfgang-Pauli-Strasse 16, 8093 Zurich (Switzerland); Conrad, M.; Reich, C.; Harbrecht, B. [Department of Chemistry and Centre of Materials Science, Philipps-Universitaet, Hans-Meerwein-Strasse, 35032 Marburg (Germany); Nesper, R. [Laboratory of Inorganic Chemistry, ETH Zurich, Wolfgang-Pauli-Strasse 10, 8093 Zurich (Switzerland)

    2012-10-15

    While HRTEM is the well-established method to characterize the structure of dodecagonal tantalum (vanadium) telluride quasicrystals and their periodic approximants, phase-contrast imaging performed on an aberration-corrected scanning transmission electron microscope (STEM) represents a favorable alternative. The (Ta,V){sub 151}Te{sub 74} clusters, the basic structural unit in all these phases, can be visualized with high resolution. A dependence of the image contrast on defocus and specimen thickness has been observed. In thin areas, the projected crystal potential is basically imaged with either dark or bright contrast at two defocus values close to Scherzer defocus as confirmed by image simulations utilizing the principle of reciprocity. Models for square-triangle tilings describing the arrangement of the basic clusters can be derived from such images. - Graphical abstract: PC-STEM image of a (Ta,V){sub 151}Te{sub 74} cluster. Highlights: Black-Right-Pointing-Pointer C{sub s}-corrected STEM is applied for the characterization of dodecagonal quasicrystals. Black-Right-Pointing-Pointer The projected potential of the structure is mirrored in the images. Black-Right-Pointing-Pointer Phase-contrast STEM imaging depends on defocus and thickness. Black-Right-Pointing-Pointer For simulations of phase-contrast STEM images, the reciprocity theorem is applicable.

  13. Comparative study of pneumocystography, positive contrast cystography and double contrast cystography in dogs

    International Nuclear Information System (INIS)

    Thibaut, J.; Parada, E.; Vargas, L.; Deppe, R.; Born, R.

    1997-01-01

    In order to compare three radiographic techniques: pneumocystography, positive contrast cystography and double contrast cystography, three series of 24 radiographs each in lateral and ventrodorsal projections were made. Six healthy adult male dogs with weight ranging between 7 and 16 kg were used. Food was withheld for 24 hours and two enemas were made before the series of radiographs were taken. Dogs were anaesthetized with sodium thiopental (20 mg/kg i.v.). The contrast medium was introduced through a urethral catheter. Pneumocystography was performed in the first series introducing air (10 ml/kg) in the bladder. Positive contrast cystography was performed in the second series introducing Hypaque M-60% diluted, contributing 100 mg of iodine per ml (10 ml/kg). In the double contrast cystography Hypaque M-60% diluted (10 ml) was introduced, in concentration of 150 mg of iodine per ml. Then air was introduced (10 ml/kg) through a catheter. Plates were taken in both projections at 1 and 10 minutes for each technique. The radiographic plates of each series were analized comparing the characteristics of radiographic density, outline and size. In neumocystography, positive contrast and double contrast cystography, the radiographic density was predominantly low, high and intermediate, respectively. The radiographic outline was mainly regular for the three techniques. With respect to bladder size, there was a decrease of height and an increase of length and width at 10 minutes. Comparing these three radiographic techniques, it can be concluded that the one that best outlines the bladder mucosa is double contrast. Pneumocystography provides the best image for opaque structures and cystography best shows the position of the urinary bladder [es

  14. Contrast-enhanced harmonic endoscopic ultrasound

    DEFF Research Database (Denmark)

    Săftoiu, A; Dietrich, C F; Vilmann, P

    2012-01-01

    Second-generation intravenous blood-pool ultrasound contrast agents are increasingly used in endoscopic ultrasound (EUS) for characterization of microvascularization, differential diagnosis of benign and malignant focal lesions, and improving staging and guidance of therapeutic procedures. Although...... initially used as Doppler signal enhancers, second-generation microbubble contrast agents are now used with specific contrast harmonic imaging techniques, which benefit from the highly nonlinear behavior of the microbubbles. Contrast-specific modes based on multi-pulse technology are used to perform...... contrast-enhanced harmonic EUS based on a very low mechanical index (0.08 - 0.12). Quantification techniques based on dynamic contrast-enhanced ultrasound have been recommended for perfusion imaging and monitoring of anti-angiogenic treatment, mainly based on time-intensity curve analysis. Most...

  15. Iodinated contrast media and contrast-induced nephropathy: is there a preferred cost-effective agent?

    Science.gov (United States)

    Sharma, Samin K

    2008-05-01

    Over 20 years have passed since the introduction of the tri-iodinated low-osmolar nonionic contrast agents such as iopamidol, iohexol, ioversol and iopromide. During this time, most cardiology practices have switched to these nonionic agents to avoid the nuisance side effects and cardiac adverse events associated with the older ionic contrast agents. Although the improved tolerability of the nonionic agents is generally attributed to their decreased osmolality (approximately half that of the older ionic contrast agents), in fact, these contrast agents also differ from the older agents in their ionicity, viscosity and direct chemotoxicity. The impact of these properties on safety, together with cost differences, should be considered when selecting a contrast agent.

  16. Liposomes loaded with contrast material for image enhancement in computed tomography: work in progress

    International Nuclear Information System (INIS)

    Ryan, P.J.; Davis, M.A.; DeGaeta, L.R.; Woda, B.; Melchior, D.L.

    1984-01-01

    Large unilamellar phospholipid vesicles were prepared and loaded with various radiographic contrast media. Body CT following in vivo adminstration of these vesicles in the rat demonstrated opacification of organs associated with the reticuloendothelial system. Image enhancement in the spleen and liver was dose dependent and was linearly related within the dose range investigated. Clearance of the radiographic contrast material was complete within 24 hours. Diffuse splenic lymphoma following intraperitoneal or intrasplenic injection of lymphoma cells, and solitary lymphoma nodules following intrahepatic injection were readily detected as nonenhanced areas following injection of liposomes

  17. Choice and technique of negative contrast in double contrast roentgenography of the stomach

    International Nuclear Information System (INIS)

    Pomakov, P.; Tomov, A.; Popsavov, P.; Tirolska, M.

    1993-01-01

    A comparative study of 8 negative contrast media is performed in 720 patients undergoing double-contrast abdominal biomedical radiography. The following preparations and methods are compared: Unibarit (Roelm, Pharma), CO 2 granulate (Nicholas), Sandosten Calcium + Calcium gluconicum (Sandoz, Pharmachim), Kalinor (Nordmark), dust variation of p. Rivieri, conducted aerophagy, stomach-tube, 'Echo'-lemonade. The average size of the gas bubble of the fornix (cm 2 ), the average volume of the gas collection (ml) and the relationship between the area of the negative contrast image (cm 2 ) and the volume of the gas (ml) is given. Some possibilities for production of domestic negative contrast media are also discussed. 2 tabs., 18 refs. (orig.)

  18. Definition of a new thermal contrast and pulse correction for defect quantification in pulsed thermography

    Science.gov (United States)

    Benítez, Hernán D.; Ibarra-Castanedo, Clemente; Bendada, AbdelHakim; Maldague, Xavier; Loaiza, Humberto; Caicedo, Eduardo

    2008-01-01

    It is well known that the methods of thermographic non-destructive testing based on the thermal contrast are strongly affected by non-uniform heating at the surface. Hence, the results obtained from these methods considerably depend on the chosen reference point. The differential absolute contrast (DAC) method was developed to eliminate the need of determining a reference point that defined the thermal contrast with respect to an ideal sound area. Although, very useful at early times, the DAC accuracy decreases when the heat front approaches the sample rear face. We propose a new DAC version by explicitly introducing the sample thickness using the thermal quadrupoles theory and showing that the new DAC range of validity increases for long times while preserving the validity for short times. This new contrast is used for defect quantification in composite, Plexiglas™ and aluminum samples.

  19. Modelling the imaging performance and low contrast detectability in digital mammography

    International Nuclear Information System (INIS)

    Spyropoulou, V; Kalyvas, N; Gaitanis, A; Michail, C; Panayiotakis, G; Kandarakis, I

    2009-01-01

    A digital x-ray mammography is a modern method for the early detection of breast cancer. The quality of a mammography image depends on various factors, the detector structure and performance being of primary importance. The aim of this work was to develop an analytical model simulating the imaging performance of a new commercially available digital mammography detector. This was achieved within the framework of the linear cascaded systems (LCS) theory. System analysis has allowed the estimation of important image quality metrics such as the Modulation Transfer Function (MTF), the Noise Power Spectrum (NPS) and the Detective Quantum Efficiency (DQE). The detector was an indirect detection system consisting of a large area, 100μm thick, CsI:TI scintillator coupled to an active matrix array of amorphous silicon (a-Si:H) photodiodes combined with thin film transistors (TFT). Pixel size was 100μm, while the active pixel dimension was 70μm. MTF and DQE data were calculated for air kerma conditions of 25, 53, 67 μGy using a 28 kVp Mo-Mo x-ray spectrum. The theoretical results were compared with published experimental data. The deviation between the theoretical and experimental MTF curves was less than 4%, while the DQE differences were found at an acceptable level. The model was also used to estimate system's capability to detect low contrast objects in the breast. It was estimated that, in the breast gland, low contrast structures larger than 1.4mm can be adequately identified by the above system.

  20. Relationship between cavitation and loss of echogenicity from ultrasound contrast agents

    OpenAIRE

    Radhakrishnan, Kirthi; Bader, Kenneth B; Haworth, Kevin J; Kopechek, Jonathan A; Raymond, Jason L; Huang, Shao-Ling; McPherson, David D; Holland, Christy K

    2013-01-01

    Ultrasound contrast agents (UCAs) have the potential to nucleate cavitation and promote both beneficial and deleterious bioeffects in vivo. Previous studies have elucidated the pulse-duration dependent pressure amplitude threshold for rapid loss of echogenicity due to UCA fragmentation. Previous studies have demonstrated that UCA fragmentation was concomitant with inertial cavitation. The purpose of this study was to evaluate the relationship between stable and inertial cavitation thresholds ...

  1. Is the transport of a gadolinium-based contrast agent decreased in a degenerated or aged disc? A post contrast MRI study.

    Directory of Open Access Journals (Sweden)

    Marta Tibiletti

    Full Text Available A post contrast magnetic resonance imaging study has been performed in a wide population of low back pain patients to investigate which radiological and phenotypic characteristics influence the penetration of the contrast agent in lumbar discs in vivo. 37 patients affected by different pathologies (disc herniation, spondylolisthesis, foraminal stenosis, central canal stenosis were enrolled in the study. The selected population included 26 male and 11 female subjects, with a mean age of 42.4 ± 9.3 years (range 18-60. Magnetic resonance images of the lumbar spine were obtained with a 1.5 T scanner (Avanto, Siemens, Erlangen, Germany with a phased-array back coil. A paramagnetic non-ionic contrast agent was injected with a dose of 0.4 ml/kg. T1-weighted magnetic resonance images were subsequently acquired at 5 time points, 5 and 10 minutes, 2, 4 and 6 hours after injection. Endplates presented clear enhancement already 5 minutes after injection, and showed an increase in the next 2 hours followed by a decrease. At 5 and 10 minutes, virtually no contrast medium was present inside the intervertebral disc; afterwards, enhancement significantly increased. Highly degenerated discs showed higher enhancement in comparison with low and medium degenerated discs. Discs classified as Pfirrmann 5 showed a statistically significant higher enhancement than Pfirrmann 1, 2 and 3 at all time points but the first one, possibly due to vascularization. Disc height collapse and Modic changes significantly increased enhancement. Presence of endplate defects did not show any significant influence on post contrast enhancement, but the lack of a clear classification of endplate defects as seen on magnetic resonance scans may be shadowing some effects. In conclusion, disc height, high level of degeneration and presence of Modic changes are factors which increase post contrast enhancement in the intervertebral disc. The effect of age could not be demonstrated.

  2. Phase Contrast Imaging

    DEFF Research Database (Denmark)

    1996-01-01

    The invention relates to a method and a system for synthesizing a prescribed intensity pattern based on phase contrast imaging that is not based on the assumption of prior art methods that the pahase shift phi is less than 1 radian. An improved method based on a simple imaging operation...... phasors attain predetermined values for predetermined spatial frequencies, and the phasor value of the specific resolution element of the spatial phase mask corresponds to a distinct intensity level of the image of the resolution element in the intensity pattern, and a spatial phase filter for phase...... shifting of a part of the electromagntic radiation, in combination with an imaging system for generation of the intensity pattern by interference in the image plane of the imaging system between the part of the electromagnetic raidation that has been phase shifted by the phase filter and the remaining part...

  3. NAD+-Dependent Deacetylase Hst1p Controls Biosynthesis and Cellular NAD+ Levels in Saccharomyces cerevisiae

    OpenAIRE

    Bedalov, Antonio; Hirao, Maki; Posakony, Jeffrey; Nelson, Melisa; Simon, Julian A.

    2003-01-01

    Nicotine adenine dinucleotide (NAD+) performs key roles in electron transport reactions, as a substrate for poly(ADP-ribose) polymerase and NAD+-dependent protein deacetylases. In the latter two processes, NAD+ is consumed and converted to ADP-ribose and nicotinamide. NAD+ levels can be maintained by regeneration of NAD+ from nicotinamide via a salvage pathway or by de novo synthesis of NAD+ from tryptophan. Both pathways are conserved from yeast to humans. We describe a critical role of the ...

  4. Quantitative measurement of normal and hydrocephalic cerebrospinal fluid flow using phase contrast cine MR imaging

    International Nuclear Information System (INIS)

    Katayama, Shinji; Asari, Shoji; Ohmoto, Takashi

    1993-01-01

    Measurements of the cerebrospinal fluid (CSF) flow using phase contrast cine magnetic resonance (MR) imaging were performed on a phantom, 12 normal subjects and 20 patients with normal pressure hydrocephalus (NPH). The phantom study demonstrated the applicability of phase contrast in quantitative measurement of the slow flow. The CSF flows of the normal subjects showed a consistent pattern with a to-and-fro movement of the flow in the anterior subarachnoid space at the C2/3 level, and they were dependent on the cardiac cycle in all subjects. However, the patients with NPH showed variable patterns of the CSF pulsatile flow and these patterns could be divided into four types according to velocity and amplitude. The amplitudes of each type were as follows: type 0 (n=1), 87.6 mm; type I (n=2), 58.2 mm (mean); type II (n=6), 48.0±5.0 mm (mean±SEM); and type III (n=11), 19.9±1.8 mm (mean±SEM). The decrease of the amplitudes correlated to a worsening of the clinical symptoms. After the shunting operation, the amplitude of to-and-fro movement of the CSF increased again in the patients with NPH who improved clinically. Some of the type III cases were reclassified type II, I and 0 and also one of the type II cases changed type I after the shunting operation. We conclude that the phase contrast cine MR imaging is a practically and clinically applicable technique for the quantitative measurement of the CSF flow. (author)

  5. Contrast-enhanced endoscopic ultrasonography

    DEFF Research Database (Denmark)

    Reddy, Nischita K; Ioncică, Ana Maria; Săftoiu, Adrian

    2011-01-01

    Contrast agents are increasingly being used to characterize the vasculature in an organ of interest, to better delineate benign from malignant pathology and to aid in staging and directing therapeutic procedures. We review the mechanisms of action of first, second and third generation contrast...... agents and their use in various endoscopic procedures in the gastrointestinal tract. Various applications of contrast-enhanced endoscopic ultrasonography include differentiating benign from malignant mediastinal lymphadenopathy, assessment of depth of invasion of esophageal, gastric and gall bladder...... cancers and visualization of the portal venous system and esophageal varices. In addition, contrast agents can be used to differentiate pancreatic lesions. The use of color Doppler further increases the ability to diagnose and differentiate various pancreatic malignancies. The sensitivity of power Doppler...

  6. The limit values for brightness and contrast adjustment in digital panoramic radiography

    Science.gov (United States)

    Zahra, A. T.; Syahraini, S. I.; Kiswanjaya, B.; Ustriyana, P.

    2017-08-01

    There is an overall lack of studies about digital panoramic radiography. The application of image enhancement techniques is still being done based on the operator’s preferences, since there is no objective limitation. The aim is to evaluate the limit values of the brightness and contrast adjustment in digital panoramic radiography. Digital panoramic radiographs were divided into three groups (dark, medium, and light), and the contrast and brightness adjustments were done using Digora for Windows. The static evaluations were done using three criteria: 1 if the image had lower quality, 2 if there was no difference and 3 if the image had better quality. The radiographic changes differed in each group depending on the initial imaging conditions. The brightness adjustment limit values in the dark and medium groups were -10 and +20, respectively, and -20 and +10 in the light group. The contrast adjustment limit values in all of the groups were -10 and +10.

  7. Cultural differences in gaze and emotion recognition: Americans contrast more than Chinese.

    Science.gov (United States)

    Stanley, Jennifer Tehan; Zhang, Xin; Fung, Helene H; Isaacowitz, Derek M

    2013-02-01

    We investigated the influence of contextual expressions on emotion recognition accuracy and gaze patterns among American and Chinese participants. We expected Chinese participants would be more influenced by, and attend more to, contextual information than Americans. Consistent with our hypothesis, Americans were more accurate than Chinese participants at recognizing emotions embedded in the context of other emotional expressions. Eye-tracking data suggest that, for some emotions, Americans attended more to the target faces, and they made more gaze transitions to the target face than Chinese. For all emotions except anger and disgust, Americans appeared to use more of a contrasting strategy where each face was individually contrasted with the target face, compared with Chinese who used less of a contrasting strategy. Both cultures were influenced by contextual information, although the benefit of contextual information depended upon the perceptual dissimilarity of the contextual emotions to the target emotion and the gaze pattern employed during the recognition task. PsycINFO Database Record (c) 2013 APA, all rights reserved.

  8. Comparative study of pneumocystography, positive contrast cystography and double contrast cystography in dogs; Estudio comparativo entre la neumocistografia, la cistografia de contraste positivo y la cistografia de doble contraste en perros

    Energy Technology Data Exchange (ETDEWEB)

    Thibaut, J.; Parada, E. [Universidad Austral de Chile, Valdivia (Chile); Vargas, L.; Deppe, R.; Born, R.

    1997-07-01

    In order to compare three radiographic techniques: pneumocystography, positive contrast cystography and double contrast cystography, three series of 24 radiographs each in lateral and ventrodorsal projections were made. Six healthy adult male dogs with weight ranging between 7 and 16 kg were used. Food was withheld for 24 hours and two enemas were made before the series of radiographs were taken. Dogs were anaesthetized with sodium thiopental (20 mg/kg i.v.). The contrast medium was introduced through a urethral catheter. Pneumocystography was performed in the first series introducing air (10 ml/kg) in the bladder. Positive contrast cystography was performed in the second series introducing Hypaque M-60% diluted, contributing 100 mg of iodine per ml (10 ml/kg). In the double contrast cystography Hypaque M-60% diluted (10 ml) was introduced, in concentration of 150 mg of iodine per ml. Then air was introduced (10 ml/kg) through a catheter. Plates were taken in both projections at 1 and 10 minutes for each technique. The radiographic plates of each series were analized comparing the characteristics of radiographic density, outline and size. In neumocystography, positive contrast and double contrast cystography, the radiographic density was predominantly low, high and intermediate, respectively. The radiographic outline was mainly regular for the three techniques. With respect to bladder size, there was a decrease of height and an increase of length and width at 10 minutes. Comparing these three radiographic techniques, it can be concluded that the one that best outlines the bladder mucosa is double contrast. Pneumocystography provides the best image for opaque structures and cystography best shows the position of the urinary bladder [Spanish] Se tomaron 3 series de 24 radiografias cada una, en proyeccion lateral y ventrodorsal. Se trabajo en cada serie con 6 perros machos clinicamente sanos 5 con un peso que vario entre los 7 y 16 kg. Previo a cada serie se efectuo

  9. Rational Thinking and Belief in Psychic Abilities: It Depends on Level of Involvement.

    Science.gov (United States)

    Stone, Anna

    2016-02-01

    Previous research has shown that lay believers in psychic abilities are more prone to intuitive thinking, less inclined to rational thinking, and have an external locus of control, compared to non-believers. Psychic practitioners, however, may have different characteristics. Psychic practitioners ( n = 31; M age = 42.7 yr., SD = 13.1), lay believers ( n = 33; M age = 33.0 yr., SD = 10.3), and non-believers ( n = 31; M age = 34.4 yr., SD = 15.4) completed questionnaires measuring thinking styles, locus of control, and psychic belief. Comparisons of lay believers with non-believers confirmed previous observations: believers had a higher propensity for intuitive thinking, lower propensity for rational thinking, and more external locus of control. In contrast, practitioners were equivalent to non-believers in rational thinking and had the highest internal locus of control. This highlights the importance of considering level of involvement with psychic practice in understanding the thinking styles of believers. Results suggested that practitioners may have rationalized their beliefs and constructed a coherent model of psychic phenomena that satisfies a propensity for rational thinking within a community of belief.

  10. 4D phase contrast flow imaging for in-stent flow visualization and assessment of stent patency in peripheral vascular stents – A phantom study

    International Nuclear Information System (INIS)

    Bunck, Alexander C.; Jüttner, Alena; Kröger, Jan Robert; Burg, Matthias C.; Kugel, Harald; Niederstadt, Thomas; Tiemann, Klaus; Schnackenburg, Bernhard; Crelier, Gerard R.

    2012-01-01

    Purpose: 4D phase contrast flow imaging is increasingly used to study the hemodynamics in various vascular territories and pathologies. The aim of this study was to assess the feasibility and validity of MRI based 4D phase contrast flow imaging for the evaluation of in-stent blood flow in 17 commonly used peripheral stents. Materials and methods: 17 different peripheral stents were implanted into a MR compatible flow phantom. In-stent visibility, maximal velocity and flow visualization were assessed and estimates of in-stent patency obtained from 4D phase contrast flow data sets were compared to a conventional 3D contrast-enhanced magnetic resonance angiography (CE-MRA) as well as 2D PC flow measurements. Results: In all but 3 of the tested stents time-resolved 3D particle traces could be visualized inside the stent lumen. Quality of 4D flow visualization and CE-MRA images depended on stent type and stent orientation relative to the magnetic field. Compared to the visible lumen area determined by 3D CE-MRA, estimates of lumen patency derived from 4D flow measurements were significantly higher and less dependent on stent type. A higher number of stents could be assessed for in-stent patency by 4D phase contrast flow imaging (n = 14) than by 2D phase contrast flow imaging (n = 10). Conclusions: 4D phase contrast flow imaging in peripheral vascular stents is feasible and appears advantageous over conventional 3D contrast-enhanced MR angiography and 2D phase contrast flow imaging. It allows for in-stent flow visualization and flow quantification with varying quality depending on stent type

  11. Cold acclimation induces distinctive changes in the chromatin state and transcript levels of COR genes in Cannabis sativa varieties with contrasting cold acclimation capacities.

    Science.gov (United States)

    Mayer, Boris F; Ali-Benali, Mohamed Ali; Demone, Jordan; Bertrand, Annick; Charron, Jean-Benoit

    2015-11-01

    Little is known about the capacity of Cannabis sativa to cold-acclimate and develop freezing tolerance. This study investigates the cold acclimation (CA) capacity of nine C. sativa varieties and the underlying genetic and epigenetic responses. The varieties were divided into three groups based on their contrasting CA capacities by comparing the survival of non-acclimated and cold-acclimated plants in whole-plant freeze tests. In response to the CA treatment, all varieties accumulated soluble sugars but only the varieties with superior capacity for CA could maintain higher levels throughout the treatment. In addition, the varieties that acclimated most efficiently accumulated higher transcript levels of cold-regulated (COR) genes and genes involved in de novo DNA methylation while displaying locus- and variety-specific changes in the levels of H3K9ac, H3K27me3 and methylcytosine (MeC) during CA. Furthermore, these hardy C. sativa varieties displayed significant increases in MeC levels at COR gene loci when deacclimated, suggesting a role for locus-specific DNA methylation in deacclimation. This study uncovers the molecular mechanisms underlying CA in C. sativa and reveals higher levels of complexity regarding how genetic, epigenetic and environmental factors intertwine. © 2014 Scandinavian Plant Physiology Society.

  12. MR mammography: influence of menstrual cycle on the dynamic contrast enhancement of fibrocystic disease

    International Nuclear Information System (INIS)

    Rieber, A.; Nuessle, K.; Merkle, E.; Tomczak, R.; Brambs, H.J.; Kreienberg, R.

    1999-01-01

    Magnetic resonance mammography (MRM) provides data regarding the nature of tumours based on contrast medium dynamics; fibrocystic changes in the breast, however, may lead to false-positive results. This study investigated whether the contrast medium dynamics of fibrocystic changes are dependent on the menstrual cycle. Twenty-four patients with palpable lumps but normal mammographies and ultrasound studies were examined. The MRM technique was performed during the first and second part of the menstrual cycle using a FLASH 3D sequence, both native and at 1, 2, 3 and 8 min after intravenous application of 0.15 mmol/kg body weight of gadodiamide. The calculated time-intensity curves were evaluated based on the following criteria: early percentage of contrast medium uptake in relation to the native value; formation of a plateau phenomenon after the second minute; the point of maximal contrast medium uptake; and calculation of the contrast enhancing index. During the second half of the menstrual cycle, a generally greater contrast medium uptake was observed. Nevertheless, when further diagnostic criteria, such as continuous contrast medium increase as a function of time, were considered, there was no increased rate of false-positive findings. The phase of the menstrual cycle may affect the specificity of the examination, if only the quantitative contrast medium uptake and the percentage of contrast medium uptake in the first 2 min are considered. A control MRM during the other half of the cycle may then be indicated and additional diagnostic criteria may improve specificity. (orig.)

  13. MR mammography: influence of menstrual cycle on the dynamic contrast enhancement of fibrocystic disease

    Energy Technology Data Exchange (ETDEWEB)

    Rieber, A.; Nuessle, K.; Merkle, E.; Tomczak, R.; Brambs, H.J. [Ulm Univ. (Germany). Abt. Radiologie 1 (Roentgendiagnostik); Kreienberg, R. [Ulm Univ. (Germany). Dept. of Gynecology

    1999-08-01

    Magnetic resonance mammography (MRM) provides data regarding the nature of tumours based on contrast medium dynamics; fibrocystic changes in the breast, however, may lead to false-positive results. This study investigated whether the contrast medium dynamics of fibrocystic changes are dependent on the menstrual cycle. Twenty-four patients with palpable lumps but normal mammographies and ultrasound studies were examined. The MRM technique was performed during the first and second part of the menstrual cycle using a FLASH 3D sequence, both native and at 1, 2, 3 and 8 min after intravenous application of 0.15 mmol/kg body weight of gadodiamide. The calculated time-intensity curves were evaluated based on the following criteria: early percentage of contrast medium uptake in relation to the native value; formation of a plateau phenomenon after the second minute; the point of maximal contrast medium uptake; and calculation of the contrast enhancing index. During the second half of the menstrual cycle, a generally greater contrast medium uptake was observed. Nevertheless, when further diagnostic criteria, such as continuous contrast medium increase as a function of time, were considered, there was no increased rate of false-positive findings. The phase of the menstrual cycle may affect the specificity of the examination, if only the quantitative contrast medium uptake and the percentage of contrast medium uptake in the first 2 min are considered. A control MRM during the other half of the cycle may then be indicated and additional diagnostic criteria may improve specificity. (orig.) With 2 figs., 2 tabs., 24 refs.

  14. Dynamic contrast-enhanced MR of the prostatic cancer and benign prostatic hyperplasia: correlation with angiogenesis

    International Nuclear Information System (INIS)

    Ni Xinchu; Shen Junkang; Lu Zhian; Zhou Lijuan; Yang Xiaochun; Wang Guanzhong; Zhang Caiyuan; Wang Shuizhen; Qian Minghui; Chan Yuxi; Qian Nong; Xiang Jianpo; Pan Changjie; Rong Weiliang; Chen Jianguo

    2005-01-01

    Objective: To evaluate the role of dynamic contrast-enhanced magnetic resonance imaging (MRI) in the diagnose of prostatic cancer and benign prostatic hyperplasia (BPH), and to determine the correlation between dynamic MRI findings with angiogenesis. Methods: Thirty-two cases of prostatic cancer and 40 cases of BPH underwent dynamic contrast-enhanced MRI. All the patients in this study were diagnosed by histopathology. The results of dynamic contrast-enhanced MRI were evaluated by early-phase enhancement parameters and time-signal intensity curves (SI-T curves), and the curves were classified according to their shapes as type I, which had steady enhancement; type II, plateau of signal intensity; and type III, washout of signal intensity. The pathologic specimens of region of interest (ROI ) were obtained, and HE staining, immunohistochemical vascular endothelial growth factor (VEGF), and microvessel density (MVD) measurements were performed. The relationships among dynamic contrast-enhanced MRI features, VEGF, and MVD expression were analyzed. Results: In the early-phase enhancement parameters of dynamic contrast-enhanced MRI, onset time, maximum signal intensity, and early-phase enhancement rate differed between prostatic cancer and BPH (P<0.01, 0.05, 0.01), but there were some overlaps between them. The intermediate and late post-contrast periods were characterized with the lesion SI-T curves. The SI-T curve of prostatic cancer was mainly type III (21 cases). Type II could be seen in both prostatic cancer (8 cases) and BPH (19 cases). Type I most appeared in BPH (18 cases). The distributions proved to have significant difference (P<0.001). The mean VEGF and MVD level of 32 prostatic cancer patients were significantly higher than those of 40 BPH patients (P<0.001). MVD level of prostatic cancer and BPH showed an association with VEGF level (P<0.01). The maximum signal intensity and early-phase enhancement rate in both prostatic cancer and BPH showed an association

  15. Managing the risk associated with use of contrast media for computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Stacul, Fulvio [Department of Radiology, University of Trieste, Cattinara Hospital, Strada di Fiume, 447, 34149 Trieste (Italy)]. E-mail: fulvio.stacul@aots.sanita.fvg.it

    2007-05-15

    Contrast agents are widely used in patients undergoing diagnostic and therapeutic imaging procedures. In recent years, there has been a significant increase in the use of iodinated contrast media (CM) due to the growing number of computed tomography (CT) procedures. Although contrast agents are generally well-tolerated, some patient subsets are at an increased risk of complications from CM. Patients at risk include those with a history of adverse reactions to CM, asthma or severe allergies, impaired renal function, older age, dehydration, congestive heart failure, or concurrent use of some drugs. Although the incidence of CM-associated complications cannot be eliminated, the chances of developing severe adverse reactions can be reduced by incorporating a number of management strategies into clinical practice. Patients at risk for acute adverse reactions can undergo pre-medication with corticosteroids, eventually associated with anti-histamines, although opinion is divided whether this prophylaxis should be used with non-ionic CM. Patients who have been identified as at risk for contrast-induced nephropathy (CIN) should be well-hydrated and have nephrotoxic medications withdrawn prior to CM exposure. Contrast dose should be decreased, as the risk of developing CIN is dose-dependent. For patients with pre-existing renal insufficiency, use of low-osmolar or iso-osmolar CM is preferable to use of high-osmolar CM. Simple strategies for preventing the risk of adverse reactions are reviewed.

  16. Managing the risk associated with use of contrast media for computed tomography

    International Nuclear Information System (INIS)

    Stacul, Fulvio

    2007-01-01

    Contrast agents are widely used in patients undergoing diagnostic and therapeutic imaging procedures. In recent years, there has been a significant increase in the use of iodinated contrast media (CM) due to the growing number of computed tomography (CT) procedures. Although contrast agents are generally well-tolerated, some patient subsets are at an increased risk of complications from CM. Patients at risk include those with a history of adverse reactions to CM, asthma or severe allergies, impaired renal function, older age, dehydration, congestive heart failure, or concurrent use of some drugs. Although the incidence of CM-associated complications cannot be eliminated, the chances of developing severe adverse reactions can be reduced by incorporating a number of management strategies into clinical practice. Patients at risk for acute adverse reactions can undergo pre-medication with corticosteroids, eventually associated with anti-histamines, although opinion is divided whether this prophylaxis should be used with non-ionic CM. Patients who have been identified as at risk for contrast-induced nephropathy (CIN) should be well-hydrated and have nephrotoxic medications withdrawn prior to CM exposure. Contrast dose should be decreased, as the risk of developing CIN is dose-dependent. For patients with pre-existing renal insufficiency, use of low-osmolar or iso-osmolar CM is preferable to use of high-osmolar CM. Simple strategies for preventing the risk of adverse reactions are reviewed

  17. Phase contrast image synthesis

    DEFF Research Database (Denmark)

    Glückstad, J.

    1996-01-01

    A new method is presented for synthesizing arbitrary intensity patterns based on phase contrast imaging. The concept is grounded on an extension of the Zernike phase contrast method into the domain of full range [0; 2 pi] phase modulation. By controlling the average value of the input phase funct...... function and by choosing appropriate phase retardation at the phase contrast filter, a pure phase to intensity imaging is accomplished. The method presented is also directly applicable in dark field image synthesis....

  18. Contrast-enhanced endoscopic ultrasonography

    DEFF Research Database (Denmark)

    Reddy, Nischita K; Ioncica, Ana Maria; Saftoiu, Adrian

    2011-01-01

    Contrast agents are increasingly being used to characterize the vasculature in an organ of interest, to better delineate benign from malignant pathology and to aid in staging and directing therapeutic procedures. We review the mechanisms of action of first, second and third generation contrast...... agents and their use in various endoscopic procedures in the gastrointestinal tract. Various applications of contrast-enhanced endoscopic ultrasonography include differentiating benign from malignant mediastinal lymphadenopathy, assessment of depth of invasion of esophageal, gastric and gall bladder...

  19. Advantage of fan beam collimators for contrast recovery of hyperfixation in clinical SPECT

    International Nuclear Information System (INIS)

    Vera, P.

    1997-01-01

    The influence of the collimator on the contrast recovery of hyperfixation was studied using a dual-headed single photon emission computer tomography (SPECT) system with standard clinical acquisition parameters. Three parallel collimator sets and two fan beam collimator sets were tested with a Jaszczak phantom. The six spheres of the phantom were filled with 99m Tc, and four background levels were progressively obtained by adding radioactivity to the cylinder of the phantom, providing four hyperfixation levels. The effects of angular sampling and reconstruction filters have been tested. The statistical analysis was performed with analysis of variance (ANOVA). This study demonstrates the advantage of ultra-high resolution fan beam collimators for contrast recovery of hyperfixation with SPECT when using 64 projections over 360 degree, in particular when the contrast is low. The authors also demonstrate that fan beam collimators permit smaller size hyperfixation detection

  20. Interval between injection of contrast material and positive contrast cheliography affects accurate diagnosis of diaphragmatic hernia

    Directory of Open Access Journals (Sweden)

    Ismail A. Sen

    2015-01-01

    Full Text Available The aim of this study was to evaluate the clinical, surgical and diagnostic imaging findings in 11 cats and 3 dogs with suspected acute and chronic traumatic diaphragmatic hernia, and to compare the results of positive contrast cheliography (peritoneography taken immediately and 5 min after the injection of contrast material. Thoracic and abdominal radiography, ultrasonography, and positive contrast cheliography of all animals were performed. Eight cases were considered as acute and six cases were considered chronic. The contrast images taken immediately after the injection of contrast material revealed the contrast material in the thoracic cavity in 8/8 acute trauma patients, but in none of the chronic cases. In 5/6 of these cases contrast material was seen in the thoracal cavity only in additional images taken after 5 min. One patient was diagnosed with FIP and excluded from the study. Twelve cases had complete resolution and one animal died during the early postoperative period. Our results suggest that positive contrast cheliography performed immediately after the injection of contrast material may not reveal chronic cases of diaphragmatic hernia and a second imaging (or imaging after 5 min is indicated in order not to overlook chronic cases.

  1. Pediatric Patients Demonstrate Progressive T1-Weighted Hyperintensity in the Dentate Nucleus following Multiple Doses of Gadolinium-Based Contrast Agent.

    Science.gov (United States)

    Roberts, D R; Chatterjee, A R; Yazdani, M; Marebwa, B; Brown, T; Collins, H; Bolles, G; Jenrette, J M; Nietert, P J; Zhu, X

    2016-12-01

    While there have been recent reports of brain retention of gadolinium following gadolinium-based contrast agent administration in adults, a retrospective series of pediatric patients has not previously been reported, to our knowledge. We investigated the relationship between the number of prior gadolinium-based contrast agent doses and increasing T1 signal in the dentate nucleus on unenhanced T1-weighted MR imaging. We hypothesized that despite differences in pediatric physiology and the smaller gadolinium-based contrast agent doses that pediatric patients are typically administered based on weighted-adjusted dosing, the pediatric brain would also demonstrate dose-dependent increasing T1 signal in the dentate nucleus. We included children with multiple gadolinium-based contrast agent administrations at our institution. A blinded reader placed ROIs within the dentate nucleus and adjacent cerebellar white matter. To eliminate reader bias, we also performed automated ROI delineation of the dentate nucleus, cerebellar white matter, and pons. Dentate-to-cerebellar white matter and dentate-to pons ratios were compared with the number of gadolinium-based contrast agent administrations. During 20 years at our institution, 280 patients received at least 5 gadolinium-based contrast agent doses, with 1 patient receiving 38 doses. Sixteen patients met the inclusion/exclusion criteria for ROI analysis. Blinded reader dentate-to-cerebellar white matter ratios were significantly associated with gadolinium-based contrast agent doses (r s = 0.77, P = .001). The dentate-to-pons ratio and dentate-to-cerebellar white matter ratios based on automated ROI placement were also significantly correlated with gadolinium-based contrast agent doses (t = 4.98, P contrast agent doses is significantly correlated with progressive T1-weighted dentate hyperintensity. Definitive confirmation of gadolinium deposition requires tissue analysis. Any potential clinical sequelae of gadolinium retention in

  2. Development of a platform for co-registered ultrasound and MR contrast imaging in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Chandrana, Chaitanya; Bevan, Peter; Hudson, John; Pang, Ian; Burns, Peter; Plewes, Donald; Chopra, Rajiv, E-mail: rajiv.chopra@sri.utoronto.ca [Sunnybrook Health Sciences Centre, Imaging Research, Department of Medical Biophysics, University of Toronto, 2075 Bayview Ave., Toronto, ON, M4N 3M5 (Canada)

    2011-02-07

    Imaging of the microvasculature is often performed using contrast agents in combination with either ultrasound (US) or magnetic resonance (MR) imaging. Contrast agents are used to enhance medical imaging by highlighting microvascular properties and function. Dynamic signal changes arising from the passage of contrast agents through the microvasculature can be used to characterize different pathologies; however, comparisons across modalities are difficult due to differences in the interactions of contrast agents with the microvasculature. Better knowledge of the relationship of contrast enhancement patterns with both modalities could enable better characterization of tissue microvasculature. We developed a co-registration platform for multi-modal US and MR imaging using clinical imaging systems in order to study the relationship between US and MR contrast enhancement. A preliminary validation study was performed in phantoms to determine the registration accuracy of the platform. In phantoms, the in-plane registration accuracy was measured to be 0.2 {+-} 0.2 and 0.3 {+-} 0.2 mm, in the lateral and axial directions, respectively. The out-of-plane registration accuracy was estimated to be 0.5 mm {+-}0.1. Co-registered US and MR imaging was performed in a rabbit model to evaluate contrast kinetics in different tissue types after bolus injections of US and MR contrast agents. The arrival time of the contrast agent in the plane of imaging was relatively similar for both modalities. We studied three different tissue types: muscle, large vessels and fat. In US, the temporal kinetics of signal enhancement were not strongly dependent on tissue type. In MR, however, due to the different amounts of agent extravasation in each tissue type, tissue-specific contrast kinetics were observed. This study demonstrates the feasibility of performing in vivo co-registered contrast US and MR imaging to study the relationships of the enhancement patterns with each modality.

  3. Development of a platform for co-registered ultrasound and MR contrast imaging in vivo

    Science.gov (United States)

    Chandrana, Chaitanya; Bevan, Peter; Hudson, John; Pang, Ian; Burns, Peter; Plewes, Donald; Chopra, Rajiv

    2011-02-01

    Imaging of the microvasculature is often performed using contrast agents in combination with either ultrasound (US) or magnetic resonance (MR) imaging. Contrast agents are used to enhance medical imaging by highlighting microvascular properties and function. Dynamic signal changes arising from the passage of contrast agents through the microvasculature can be used to characterize different pathologies; however, comparisons across modalities are difficult due to differences in the interactions of contrast agents with the microvasculature. Better knowledge of the relationship of contrast enhancement patterns with both modalities could enable better characterization of tissue microvasculature. We developed a co-registration platform for multi-modal US and MR imaging using clinical imaging systems in order to study the relationship between US and MR contrast enhancement. A preliminary validation study was performed in phantoms to determine the registration accuracy of the platform. In phantoms, the in-plane registration accuracy was measured to be 0.2 ± 0.2 and 0.3 ± 0.2 mm, in the lateral and axial directions, respectively. The out-of-plane registration accuracy was estimated to be 0.5 mm ±0.1. Co-registered US and MR imaging was performed in a rabbit model to evaluate contrast kinetics in different tissue types after bolus injections of US and MR contrast agents. The arrival time of the contrast agent in the plane of imaging was relatively similar for both modalities. We studied three different tissue types: muscle, large vessels and fat. In US, the temporal kinetics of signal enhancement were not strongly dependent on tissue type. In MR, however, due to the different amounts of agent extravasation in each tissue type, tissue-specific contrast kinetics were observed. This study demonstrates the feasibility of performing in vivo co-registered contrast US and MR imaging to study the relationships of the enhancement patterns with each modality.

  4. Effects of voluntary exercise on the viability, proliferation and BDNF levels of bone marrow stromal cells in rat pups born from morphine- dependent mothers during pregnancy.

    Science.gov (United States)

    Haydari, Sakineh; Safari, Manouchehr; Zarbakhsh, Sam; Bandegi, Ahmad Reza; Miladi-Gorji, Hossein

    2016-11-10

    This study was designed to investigate whether free access to a running wheel during pregnancy in morphine-dependent mothers would influence the viability, proliferation and BDNF levels of bone marrow stromal cells in rat pups. Pregnant rats were made dependent by chronic administration of morphine in drinking water simultaneously with free access to a running wheel. Male pups are weaned at 21days of birth and their bones marrows were aspirated from the femurs and tibias and also the bone marrow stromal cells (BMSCs) cultured. MTT assay was used to determine cell viability and proliferation rate. The level of BDNF was measured in the supernant of BMSCs culture by ELISA. The sedentary morphine-dependent mothers' pups showed a significant increase in the percentage cell viability and proliferation rate and also a significant decrease in the BDNF protein levels in BMSCs. The rat pups borne from exercising the control and morphine-dependent mothers exhibited an increase in the percentage viability, proliferation rate and BDNF levels of the BMSCs. This study showed that maternal exercise during pregnancy in morphine-dependent and non-dependent mothers, with increasing of BDNF levels increased the proliferation and viability of BMSCs in the rat pups. Also, chronic administration of morphine during pregnancy was able to increase the proliferation and viability of BMSCs in the rat pups. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Low contrast detectability and spatial resolution with model-based iterative reconstructions of MDCT images: a phantom and cadaveric study

    Energy Technology Data Exchange (ETDEWEB)

    Millon, Domitille; Coche, Emmanuel E. [Universite Catholique de Louvain, Department of Radiology and Medical Imaging, Cliniques Universitaires Saint Luc, Brussels (Belgium); Vlassenbroek, Alain [Philips Healthcare, Brussels (Belgium); Maanen, Aline G. van; Cambier, Samantha E. [Universite Catholique de Louvain, Statistics Unit, King Albert II Cancer Institute, Brussels (Belgium)

    2017-03-15

    To compare image quality [low contrast (LC) detectability, noise, contrast-to-noise (CNR) and spatial resolution (SR)] of MDCT images reconstructed with an iterative reconstruction (IR) algorithm and a filtered back projection (FBP) algorithm. The experimental study was performed on a 256-slice MDCT. LC detectability, noise, CNR and SR were measured on a Catphan phantom scanned with decreasing doses (48.8 down to 0.7 mGy) and parameters typical of a chest CT examination. Images were reconstructed with FBP and a model-based IR algorithm. Additionally, human chest cadavers were scanned and reconstructed using the same technical parameters. Images were analyzed to illustrate the phantom results. LC detectability and noise were statistically significantly different between the techniques, supporting model-based IR algorithm (p < 0.0001). At low doses, the noise in FBP images only enabled SR measurements of high contrast objects. The superior CNR of model-based IR algorithm enabled lower dose measurements, which showed that SR was dose and contrast dependent. Cadaver images reconstructed with model-based IR illustrated that visibility and delineation of anatomical structure edges could be deteriorated at low doses. Model-based IR improved LC detectability and enabled dose reduction. At low dose, SR became dose and contrast dependent. (orig.)

  6. Super-nonlinear fluorescence microscopy for high-contrast deep tissue imaging

    Science.gov (United States)

    Wei, Lu; Zhu, Xinxin; Chen, Zhixing; Min, Wei

    2014-02-01

    Two-photon excited fluorescence microscopy (TPFM) offers the highest penetration depth with subcellular resolution in light microscopy, due to its unique advantage of nonlinear excitation. However, a fundamental imaging-depth limit, accompanied by a vanishing signal-to-background contrast, still exists for TPFM when imaging deep into scattering samples. Formally, the focusing depth, at which the in-focus signal and the out-of-focus background are equal to each other, is defined as the fundamental imaging-depth limit. To go beyond this imaging-depth limit of TPFM, we report a new class of super-nonlinear fluorescence microscopy for high-contrast deep tissue imaging, including multiphoton activation and imaging (MPAI) harnessing novel photo-activatable fluorophores, stimulated emission reduced fluorescence (SERF) microscopy by adding a weak laser beam for stimulated emission, and two-photon induced focal saturation imaging with preferential depletion of ground-state fluorophores at focus. The resulting image contrasts all exhibit a higher-order (third- or fourth- order) nonlinear signal dependence on laser intensity than that in the standard TPFM. Both the physical principles and the imaging demonstrations will be provided for each super-nonlinear microscopy. In all these techniques, the created super-nonlinearity significantly enhances the imaging contrast and concurrently extends the imaging depth-limit of TPFM. Conceptually different from conventional multiphoton processes mediated by virtual states, our strategy constitutes a new class of fluorescence microscopy where high-order nonlinearity is mediated by real population transfer.

  7. X-ray speckle contrast variation at a sample-specific absorption edges

    International Nuclear Information System (INIS)

    Retsch, C. C.; Wang, Y.; Frigo, S. P.; Stephenson, G. B.; McNulty, I.

    2000-01-01

    The authors measured static x-ray speckle contrast variation with the incident photon energy across sample-specific absorption edges. They propose that the variation depends strongly on the spectral response function of the monochromator. Speckle techniques have been introduced to the x-ray regime during recent years. Most of these experiments, however, were done at photon energies above 5 keV. They are working on this technique in the 1 to 4 keV range, an energy range that includes many important x-ray absorption edges, e.g., in Al, Si, P, S, the rare-earths, and others. To their knowledge, the effect of absorption edges on speckle contrast has not yet been studied. In this paper, they present their initial measurements and understanding of the observed phenomena

  8. Vascular Steal Explains Early Paradoxical Blood Oxygen Level-Dependent Cerebrovascular Response in Brain Regions with Delayed Arterial Transit Times

    Directory of Open Access Journals (Sweden)

    Julien Poublanc

    2013-04-01

    Full Text Available Introduction: Blood oxygen level-dependent (BOLD magnetic resonance imaging (MRI during manipulation of inhaled carbon dioxide (CO2 can be used to measure cerebrovascular reactivity (CVR and map regions of exhausted cerebrovascular reserve. These regions exhibit a reduced or negative BOLD response to inhaled CO2. In this study, we sought to clarify the mechanism behind the negative BOLD response by investigating its time delay (TD. Dynamic susceptibility contrast (DSC MRI with the injection of a contrast agent was used as the gold standard in order to provide measurement of the blood arrival time to which CVR TD could be compared. We hypothesize that if negative BOLD responses are the result of a steal phenomenon, they should be synchronized with positive BOLD responses from healthy brain tissue, even though the blood arrival time would be delayed. Methods: On a 3-tesla MRI system, BOLD CVR and DSC images were collected in a group of 19 patients with steno-occlusive cerebrovascular disease. For each patient, we generated a CVR magnitude map by regressing the BOLD signal with the end-tidal partial pressure of CO2 (PETCO2, and a CVR TD map by extracting the time of maximum cross-correlation between the BOLD signal and PETCO2. In addition, a blood arrival time map was generated by fitting the DSC signal with a gamma variate function. ROI masks corresponding to varying degrees of reactivity were constructed. Within these masks, the mean CVR magnitude, CVR TD and DSC blood arrival time were extracted and averaged over the 19 patients. CVR magnitude and CVR TD were then plotted against DSC blood arrival time. Results: The results show that CVR magnitude is highly correlated to DSC blood arrival time. As expected, the most compromised tissues with the longest blood arrival time have the lowest (most negative CVR magnitude. However, CVR TD shows a noncontinuous relationship with DSC blood arrival time. CVR TD is well correlated to DSC blood arrival time

  9. Enhanced renal image contrast by ethanol fixation in phase-contrast X-ray computed tomography.

    Science.gov (United States)

    Shirai, Ryota; Kunii, Takuya; Yoneyama, Akio; Ooizumi, Takahito; Maruyama, Hiroko; Lwin, Thet Thet; Hyodo, Kazuyuki; Takeda, Tohoru

    2014-07-01

    Phase-contrast X-ray imaging using a crystal X-ray interferometer can depict the fine structures of biological objects without the use of a contrast agent. To obtain higher image contrast, fixation techniques have been examined with 100% ethanol and the commonly used 10% formalin, since ethanol causes increased density differences against background due to its physical properties and greater dehydration of soft tissue. Histological comparison was also performed. A phase-contrast X-ray system was used, fitted with a two-crystal X-ray interferometer at 35 keV X-ray energy. Fine structures, including cortex, tubules in the medulla, and the vessels of ethanol-fixed kidney could be visualized more clearly than that of formalin-fixed tissues. In the optical microscopic images, shrinkage of soft tissue and decreased luminal space were observed in ethanol-fixed kidney; and this change was significantly shown in the cortex and outer stripe of the outer medulla. The ethanol fixation technique enhances image contrast by approximately 2.7-3.2 times in the cortex and the outer stripe of the outer medulla; the effect of shrinkage and the physical effect of ethanol cause an increment of approximately 78% and 22%, respectively. Thus, the ethanol-fixation technique enables the image contrast to be enhanced in phase-contrast X-ray imaging.

  10. Time-dependent changes of levels of endogenous epidermal growth factor in submandibular glands, in kidneys, and in urine in rats during systemic treatment with EGF

    DEFF Research Database (Denmark)

    Vinter-Jensen, Lars; Jørgensen, P E; Thulesen, J

    1998-01-01

    Exogenous EGF influences the levels of endogenous EGF differently in the submandibular glands (SMG) and the kidneys. The aim of the present study was to examine the time-dependent changes in levels of endogenous EGF during 1-4 weeks of EGF treatment.......Exogenous EGF influences the levels of endogenous EGF differently in the submandibular glands (SMG) and the kidneys. The aim of the present study was to examine the time-dependent changes in levels of endogenous EGF during 1-4 weeks of EGF treatment....

  11. A finite-difference contrast source inversion method

    International Nuclear Information System (INIS)

    Abubakar, A; Hu, W; Habashy, T M; Van den Berg, P M

    2008-01-01

    We present a contrast source inversion (CSI) algorithm using a finite-difference (FD) approach as its backbone for reconstructing the unknown material properties of inhomogeneous objects embedded in a known inhomogeneous background medium. Unlike the CSI method using the integral equation (IE) approach, the FD-CSI method can readily employ an arbitrary inhomogeneous medium as its background. The ability to use an inhomogeneous background medium has made this algorithm very suitable to be used in through-wall imaging and time-lapse inversion applications. Similar to the IE-CSI algorithm the unknown contrast sources and contrast function are updated alternately to reconstruct the unknown objects without requiring the solution of the full forward problem at each iteration step in the optimization process. The FD solver is formulated in the frequency domain and it is equipped with a perfectly matched layer (PML) absorbing boundary condition. The FD operator used in the FD-CSI method is only dependent on the background medium and the frequency of operation, thus it does not change throughout the inversion process. Therefore, at least for the two-dimensional (2D) configurations, where the size of the stiffness matrix is manageable, the FD stiffness matrix can be inverted using a non-iterative inversion matrix approach such as a Gauss elimination method for the sparse matrix. In this case, an LU decomposition needs to be done only once and can then be reused for multiple source positions and in successive iterations of the inversion. Numerical experiments show that this FD-CSI algorithm has an excellent performance for inverting inhomogeneous objects embedded in an inhomogeneous background medium

  12. Rat Tumor Response to the Vascular-Disrupting Agent 5,6-Dimethylxanthenone-4-Acetic Acid as Measured by Dynamic Contrast-Enhanced Magnetic Resonance Imaging, Plasma 5-Hydroxyindoleacetic Acid Levels, and Tumor Necrosis1

    OpenAIRE

    McPhail, Lesley D; McIntyre, Dominick J O; Ludwig, Christian; Kestell, Philip; Griffiths, John R; Kelland, Lloyd R; Robinson, Simon P

    2006-01-01

    The dose-dependent effects of 5,6-dimethylxanthenone-4-acetic acid (DMXAA) on rat GH3 prolactinomas were investigated in vivo. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) was used to assess tumor blood flow/permeability pretreatment and 24 hours posttreatment with 0, 100, 200, or 350 mg/kg DMXAA. DCE-MRI data were analyzed using Ktrans and the integrated area under the gadolinium time curve (IAUGC) as response biomarkers. Highperformance liquid chromatography (HPLC) was use...

  13. A gaze-contingent display to study contrast sensitivity under natural viewing conditions

    Science.gov (United States)

    Dorr, Michael; Bex, Peter J.

    2011-03-01

    Contrast sensitivity has been extensively studied over the last decades and there are well-established models of early vision that were derived by presenting the visual system with synthetic stimuli such as sine-wave gratings near threshold contrasts. Natural scenes, however, contain a much wider distribution of orientations, spatial frequencies, and both luminance and contrast values. Furthermore, humans typically move their eyes two to three times per second under natural viewing conditions, but most laboratory experiments require subjects to maintain central fixation. We here describe a gaze-contingent display capable of performing real-time contrast modulations of video in retinal coordinates, thus allowing us to study contrast sensitivity when dynamically viewing dynamic scenes. Our system is based on a Laplacian pyramid for each frame that efficiently represents individual frequency bands. Each output pixel is then computed as a locally weighted sum of pyramid levels to introduce local contrast changes as a function of gaze. Our GPU implementation achieves real-time performance with more than 100 fps on high-resolution video (1920 by 1080 pixels) and a synthesis latency of only 1.5ms. Psychophysical data show that contrast sensitivity is greatly decreased in natural videos and under dynamic viewing conditions. Synthetic stimuli therefore only poorly characterize natural vision.

  14. 29 CFR 779.419 - Dependence of the section 7(i) overtime pay exemption upon the level of the employee's “regular...

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 3 2010-07-01 2010-07-01 false Dependence of the section 7(i) overtime pay exemption upon the level of the employee's âregular rateâ of pay. 779.419 Section 779.419 Labor Regulations Relating... Compensated Principally by Commissions § 779.419 Dependence of the section 7(i) overtime pay exemption upon...

  15. Propositional Logics of Dependence

    NARCIS (Netherlands)

    Yang, F.; Väänänen, J.

    2016-01-01

    In this paper, we study logics of dependence on the propositional level. We prove that several interesting propositional logics of dependence, including propositional dependence logic, propositional intuitionistic dependence logic as well as propositional inquisitive logic, are expressively complete

  16. Evaluation of contrast in duplicated radiographs

    International Nuclear Information System (INIS)

    Thunthy, K.H.; Weinberg, R.

    1982-01-01

    This investigation evaluated changes in the contrast of duplicated radiographs made at different ultraviolet light exposures. Increasing ultraviolet light exposure had different effects on the duplicates of originals of different background densities. When correctly exposed, a duplicate radiograph enhanced contrast. When originals had the same contrast but different background densities, their duplicates did not have the same contrast. It was not possible to duplicate accurately all the different contrasts measured on an original. It was possible, however, to produce duplicates with all contrasts greater than those of the original

  17. Estimating the arterial input function from dynamic contrast-enhanced MRI data with compensation for flow enhancement (I): Theory, method, and phantom experiments

    NARCIS (Netherlands)

    van Schie, Jeroen J. N.; Lavini, Cristina; van Vliet, Lucas J.; Vos, Frans M.

    2017-01-01

    The arterial input function (AIF) represents the time-dependent arterial contrast agent (CA) concentration that is used in pharmacokinetic modeling. To develop a novel method for estimating the AIF from dynamic contrast-enhanced (DCE-) MRI data, while compensating for flow enhancement. Signal

  18. Residual strain, scale effects, and time-dependent behaviour at the 240-m level of the underground research laboratory

    International Nuclear Information System (INIS)

    Read, R.S.

    1990-01-01

    Two subhorizontal, orthogonal boreholes were monitored continuously during concentric overcoring at the 240-m level of the Underground Research Laboratory (URL). The magnitude and orientation of principal residual strain components in the near-field stress regime were determined assuming linear elastic behaviour of the rock mass and isotropic conditions. In terms of magnitude, results compared favourably with those from previous tests at the 240-m level. However, orientation results were inconclusive. The effects of scale and borehole orientation relative to the principal stress direction on the results from a modified CSIR triaxial cell overcore test were also investigated; no scale effects were apparent in the experiment, but borehole orientation did affect results. Finally, time-dependent behaviour was detected in the Lac du Bonnet granite, and was monitored between successive overcore tests in one of the boreholes. Results on residual strain, scale effects, and time-dependent behaviour are presented, along with limitations and possible modifications to the testing procedure

  19. Occupation number dependence of molecular energy levels

    International Nuclear Information System (INIS)

    Giambiagi, M.S. de; Giambiagi, M.; Ferreira, R.

    1977-08-01

    The Roothaan expression for the energy of a closed-shell molecular system is generalized in order to apply to open shells. A continuous variation from 0 to 2 is supposed for each level's occupation number, extending to this range tbe correction due to the spurious repulsion appearing in the half-electron method. The characteristic equations of the Xα method are applied to the energy expressions. The one level case is discussed in detail. Ionic and excited states of the 1,3 transbutadiene π system are analyzed

  20. Contrast-enhanced peripheral MRA

    DEFF Research Database (Denmark)

    Nielsen, Yousef W; Thomsen, Henrik S

    2012-01-01

    MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic......-state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged...... intravascular stay, due to macromolecular structure or protein binding. These agents can be used for first-pass, as well as steady-state MRA. Some Gd-based contrast agents with low thermodynamic stability have been linked to development of nephrogenic systemic fibrosis in patients with severe renal...

  1. Gibberellic acid and cGMP-dependent transcriptional regulation in arabidopsis thaliana

    KAUST Repository

    Bastian, René

    2010-03-01

    An ever increasing amount of transcriptomic data and analysis tools provide novel insight into complex responses of biological systems. Given these resources we have undertaken to review aspects of transcriptional regulation in response to the plant hormone gibberellic acid (GA) and its second messenger guanosine 3\\',5\\'-cyclic monophosphate (cGMP) in Arabidopsis thaliana, both wild type and selected mutants. Evidence suggests enrichment of GA-responsive (GARE) elements in promoters of genes that are transcriptionally upregulated in response to cGMP but downregulated in a GA insensitive mutant (ga1-3). In contrast, in the genes upregulated in the mutant, no enrichment in the GARE is observed suggesting that GARE motifs are diagnostic for GA-induced and cGMP-dependent transcriptional upregulation. Further, we review how expression studies of GA-dependent transcription factors and transcriptional networks based on common promoter signatures derived from ab initio analyses can contribute to our understanding of plant responses at the systems level. © 2010 Landes Bioscience.

  2. A new combined technique for automatic contrast enhancement of digital images

    Directory of Open Access Journals (Sweden)

    Ismail A. Humied

    2012-03-01

    Full Text Available Some low contrast images have certain characteristics makes it difficult to use traditional methods to improve it. An example of these characteristics, that the amplitudes of images histogram components are very high at one location on the gray scale and very small in the rest of the gray scale. In the present paper, a new method is described. It can deal with such cases. The proposed method is a combination of Histogram Equalization (HE and Fast Gray-Level Grouping (FGLG. The basic procedure of this method is segments the original histogram of a low contrast image into two sub-histograms according to the location of the highest amplitude of the histogram components, and achieving contrast enhancement by equalizing the left segment of the histogram components using (HE technique and using (FGLG technique to equalize the right segment of this histogram components. The results have shown that the proposed method does not only produce better results than each individual contrast enhancement technique, but it is also fully automated. Moreover, it is applicable to a broad variety of images that satisfy the properties mentioned above and suffer from low contrast.

  3. Dose-dependent effects of an immune challenge at both ultimate and proximate levels in Drosophila melanogaster.

    Science.gov (United States)

    Nystrand, M; Dowling, D K

    2014-05-01

    Immune responses are highly dynamic. The magnitude and efficiency of an immune response to a pathogen can change markedly across individuals, and such changes may be influenced by variance in a range of intrinsic (e.g. age, genotype, sex) and external (e.g. abiotic stress, pathogen identity, strain) factors. Life history theory predicts that up-regulation of the immune system will come at a physiological cost, and studies have confirmed that increased investment in immunity can reduce reproductive output and survival. Furthermore, males and females often have divergent reproductive strategies, and this might drive the evolution of sex-specific life history trade-offs involving immunity, and sexual dimorphism in immune responses per se. Here, we employ an experiment design to elucidate dose-dependent and sex-specific responses to exposure to a nonpathogenic immune elicitor at two scales--the 'ultimate' life history and the underlying 'proximate' immune level in Drosophila melanogaster. We found dose-dependent effects of immune challenges on both male and female components of reproductive success, but not on survival, as well as a response in antimicrobial activity. These results indicate that even in the absence of the direct pathogenic effects that are associated with actual disease, individual life histories respond to a perceived immune challenge--but with the magnitude of this response being contingent on the initial dose of exposure. Furthermore, the results indicate that immune responses at the ultimate life history level may indeed reflect underlying processes that occur at the proximate level. © 2014 The Authors. Journal of Evolutionary Biology © 2014 European Society For Evolutionary Biology.

  4. Brain-wide pathway for waste clearance captured by contrast-enhanced MRI.

    Science.gov (United States)

    Iliff, Jeffrey J; Lee, Hedok; Yu, Mei; Feng, Tian; Logan, Jean; Nedergaard, Maiken; Benveniste, Helene

    2013-03-01

    The glymphatic system is a recently defined brain-wide paravascular pathway for cerebrospinal fluid (CSF) and interstitial fluid (ISF) exchange that facilitates efficient clearance of solutes and waste from the brain. CSF enters the brain along para-arterial channels to exchange with ISF, which is in turn cleared from the brain along para-venous pathways. Because soluble amyloid β clearance depends on glymphatic pathway function, we proposed that failure of this clearance system contributes to amyloid plaque deposition and Alzheimer's disease progression. Here we provide proof of concept that glymphatic pathway function can be measured using a clinically relevant imaging technique. Dynamic contrast-enhanced MRI was used to visualize CSF-ISF exchange across the rat brain following intrathecal paramagnetic contrast agent administration. Key features of glymphatic pathway function were confirmed, including visualization of para-arterial CSF influx and molecular size-dependent CSF-ISF exchange. Whole-brain imaging allowed the identification of two key influx nodes at the pituitary and pineal gland recesses, while dynamic MRI permitted the definition of simple kinetic parameters to characterize glymphatic CSF-ISF exchange and solute clearance from the brain. We propose that this MRI approach may provide the basis for a wholly new strategy to evaluate Alzheimer's disease susceptibility and progression in the live human brain.

  5. Physiological relevance of plant 2-Cys peroxiredoxin overoxidation level and oligomerization status.

    Science.gov (United States)

    Cerveau, Delphine; Ouahrani, Djelloul; Marok, Mohamed Amine; Blanchard, Laurence; Rey, Pascal

    2016-01-01

    Peroxiredoxins are ubiquitous thioredoxin-dependent peroxidases presumed to display, upon environmental constraints, a chaperone function resulting from a redox-dependent conformational switch. In this work, using biochemical and genetic approaches, we aimed to unravel the factors regulating the redox status and the conformation of the plastidial 2-Cys peroxiredoxin (2-Cys PRX) in plants. In Arabidopsis, we show that in optimal growth conditions, the overoxidation level mainly depends on the availability of thioredoxin-related electron donors, but not on sulfiredoxin, the enzyme reducing the 2-Cys PRX overoxidized form. We also observed that upon various physiological temperature, osmotic and light stress conditions, the overoxidation level and oligomerization status of 2-Cys PRX can moderately vary depending on the constraint type. Further, no major change was noticed regarding protein conformation in water-stressed Arabidopsis, barley and potato plants, whereas species-dependent up- and down-variations in overoxidation were observed. In contrast, both 2-Cys PRX overoxidation and oligomerization were strongly induced during a severe oxidative stress generated by methyl viologen. From these data, revealing that the oligomerization status of plant 2-Cys PRX does not exhibit important variation and is not tightly linked to the protein redox status upon physiologically relevant environmental constraints, the possible in planta functions of 2-Cys PRX are discussed. © 2015 John Wiley & Sons Ltd.

  6. Interactive effects of size, contrast, intensity and configuration of background objects in evoking disruptive camouflage in cuttlefish.

    Science.gov (United States)

    Chiao, Chuan-Chin; Chubb, Charles; Hanlon, Roger T

    2007-07-01

    Disruptive body coloration is a primary camouflage tactic of cuttlefish. Because rapid changeable coloration of cephalopods is guided visually, we can present different visual backgrounds (e.g., computer-generated, two-dimensional prints) and video record the animal's response by describing and grading its body pattern. We showed previously that strength of cuttlefish disruptive patterning depends on the size, contrast, and density of discrete light elements on a homogeneous dark background. Here we report five experiments on the interactions of these and other features. Results show that Weber contrast of light background elements is--in combination with element size--a powerful determinant of disruptive response strength. Furthermore, the strength of disruptive patterning decreases with increasing mean substrate intensity (with other factors held constant). Interestingly, when element size, Weber contrast and mean substrate intensity are kept constant, strength of disruptive patterning depends on the configuration of clusters of small light elements. This study highlights the interactions of multiple features of natural microhabitats that directly influence which camouflage pattern a cuttlefish will choose.

  7. Contrast of artificial subcutaneous hematomas in MRI over time.

    Science.gov (United States)

    Hassler, Eva Maria; Ogris, Kathrin; Petrovic, Andreas; Neumayer, Bernhard; Widek, Thomas; Yen, Kathrin; Scheurer, Eva

    2015-03-01

    In clinical forensic medicine, hematomas and other externally visible injuries build the basis for the reconstruction of events. However, dating of subcutaneous hematomas based on their external aspect is difficult. Magnetic resonance imaging (MRI) has proven its use in dating intracranial hemorrhage. Thus, the aim was to investigate if MRI can also be used for dating subcutaneous hematomas and to analyze an eventual influence of the hematoma shape. In 20 healthy volunteers (11 females, 9 males, aged 26.9 ± 3.8 years), 4 ml of autologous blood were injected subcutaneously in the thigh. The hematoma was scanned immediately after the injection, after 3 and 24 h and 3, 7, and 14 days using three sequences with different contrast. Data was analyzed by measuring signal intensities of the hematoma, the muscle, and the subcutaneous tissue over time, and the Michelson contrast coefficients between the tissues were calculated. In the analysis, hematoma shape was considered. Signal intensity of blood in the proton density-weighted sequence reached its maximum 3 h after the injection with a subsequent decrease, whereas the signal intensities of muscle and fatty tissue remained constant. The time course of the Michelson coefficient of blood versus muscle decreased exponentially with a change from hyperintensity to hypointensity at 116.9 h, depending on hematoma shape. In the other sequences, either variability was large or contrast coefficients stayed constant over time. The observed change of contrast of blood versus muscle permits a quick estimate of a hematoma's age. The consideration of the hematoma shape is expected to further enhance dating using MRI.

  8. Contrast Runoff Correlates with the Clinical Outcome of Cervical Epidural Neuroplasty Using a Racz Catheter.

    Science.gov (United States)

    Han, Yun-Joung; Lee, Myoung No; Cho, Min Ji; Park, Hue Jung; Moon, Dong Eon; Kim, Young Hoon

    2016-01-01

    Epidural neuroplasty using a Racz catheter has a therapeutic effect. Studies have found no correlation between foraminal stenosis and the outcome of epidural neuroplasty, which is thought to depend on contrast runoff. To examine the correlation between the contrast spread pattern and pain reduction in cervical epidural neuroplasty using a Racz catheter. Retrospective study. An interventional pain-management practice in a university hospital. Fluoroscopic images were reviewed retrospectively. The spread of contrast from the neural foramen to a nerve root was called contrast runoff. If the contrast did not spread in this manner, then there was no contrast runoff. We defined successful epidural neuroplasty as a 50% or greater reduction from the pre-procedure numeric rating scale (NRS) score for total pain, and an at least 40% reduction in the neck pain and disability scale (NPDS) score. This study reviewed 169 patients. Among the patients who had a contrast runoff pattern, the epidural neuroplasty was rated as successful in 96 (74.4%), 97 (75.2%), 86 (66.7%), and 79 (61.2%) cases one, 3, 6, and 12 months after the procedure, respectively. When there was no contrast runoff, the epidural neuroplasty was successful in 12 (30%), 12 (30%), 10 (25%), and 10 (25%) cases at one, 3, 6, and 12 months after the procedure (P runoff pattern had odds ratios of 6.788, 7.073, 6.000, and 4.740 at one, 3, 6, and 12 months, respectively (P runoff pattern had a higher success rate. Contrast runoff should be observed during neuroplasty, even in the presence of foraminal stenosis. Cervical spinal pain, contrast, contrast runoff, epidural neuroplasty, percutaneous adhesiolysis, Racz catheter.

  9. Gustatory thalamus lesions in the rat: III. Simultaneous contrast and autoshaping.

    Science.gov (United States)

    Reilly, S; Pritchard, T C

    1997-12-01

    The performance of rats with electrophysiologically guided electrolytic lesions of the gustatory thalamus (GT) was compared to that of control subjects in two experiments. In Experiment 1, the lesioned rats showed normal simultaneous contrast effects (both positive and negative) during brief, alternating access to 0.15% saccharin and 1.0 M sucrose. There was, however, a substantial lesion-induced impairment in the level of conditioned stimulus-directed maintenance responding on the autoshaping procedure of Experiment 2. These findings are discussed with respect to the anticipatory contrast deficit recently reported in GT-lesioned rats.

  10. Dual focal-spot imaging for phase extraction in phase-contrast radiography

    International Nuclear Information System (INIS)

    Donnelly, Edwin F.; Price, Ronald R.; Pickens, David R.

    2003-01-01

    The purpose of this study was to evaluate dual focal spot imaging as a method for extracting the phase component from a phase-contrast radiography image. All measurements were performed using a microfocus tungsten-target x-ray tube with an adjustable focal-spot size (0.01 mm to 0.045 mm). For each object, high-resolution digital radiographs were obtained with two different focal spot sizes to produce matched image pairs in which all other geometric variables as well as total exposure and tube kVp were held constant. For each image pair, a phase extraction was performed using pixel-wise division. The phase-extracted image resulted in an image similar to the standard image processing tool commonly referred to as 'unsharp masking' but with the additional edge-enhancement produced by phase-contrast effects. The phase-extracted image illustrates the differences between the two images whose imaging parameters differ only in focal spot size. The resulting image shows effects from both phase contrast as well as geometric unsharpness. In weakly attenuating materials the phase-contrast effect predominates, while in strongly attenuating materials the phase effects are so small that they are not detectable. The phase-extracted image in the strongly attenuating object reflects differences in geometric unsharpness. The degree of phase extraction depends strongly on the size of the smallest focal spot used. This technique of dual-focal spot phase-contrast radiography provides a simple technique for phase-component (edge) extraction in phase-contrast radiography. In strongly attenuating materials the phase-component is overwhelmed by differences in geometric unsharpness. In these cases the technique provides a form of unsharp masking which also accentuates the edges. Thus, the two effects are complimentary and may be useful in the detection of small objects

  11. Contrast-induced nephropathy following intravenous urography with Iopromid

    International Nuclear Information System (INIS)

    Krysteva, R.; Andreev, E.; Kirojcheva, M.; Kundurdzhiev, A.; Kiperova, B.

    1997-01-01

    In retrospective studies the incidence of contrast-induced nephropathy is less than 1 per cent, while in prospective ones it may reach up to 10 per cent. Thirty-nine patients (9 men and 30 women at mean age 46.6 ± 16.5 years, range 15 - 75) undergo prospective study by iv urography with Iopramid (Ultravist 370) administered at mean dose 0.9 ± 0.1 ml/kg b.w. The patients are distributed in 3 groups: group I - with normal renal function free of diabetes mellitus (33 cases), group II - with normal renal function and diabetes mellitus, group III - with renal failure free of diabetes mellitus (plasma creatinine concentration (Pcr) > 140 μmol/l). Pcr is evaluated prior to (baseline) and 48 hours after urography. Dehydration is precluded and none of the patients is given nephrotoxic drugs. In group I Pcr shows a more than 25 per cent increase in 4 patients, but remains below 140 μmol/l. In 2 patients of the same group Pcr levels exceed the reference values: from 51 to 205, and from 105 to 196 μmol/l in two women aged 70 and 74 years, respectively. Renal function impairment is reversible, with Pcr returning to normal within a week. In groups II and III no changes in Pcr level are noted. A slight elevation of serum creatinine pointing to contrast-induced nephrotoxicity is documented in 4 patients with previously normal renal function. A reversible renal failure is observed in two instances. The obtained results demonstrate an incidence rate of contrast-induced nephropathy amounting to 15.4 per cent, or in 6/39 patients (author)

  12. Contrast analysis : A tutorial

    NARCIS (Netherlands)

    Haans, A.

    2018-01-01

    Contrast analysis is a relatively simple but effective statistical method for testing theoretical predictions about differences between group means against the empirical data. Despite its advantages, contrast analysis is hardly used to date, perhaps because it is not implemented in a convenient

  13. Benchtop phase-contrast X-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gundogdu, O. [Department of Physics, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom)], E-mail: o.gundogdu@surrey.ac.uk; Nirgianaki, E.; Che Ismail, E.; Jenneson, P.M.; Bradley, D.A. [Department of Physics, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom)

    2007-12-15

    Clinical radiography has traditionally been based on contrast obtained from absorption when X-rays pass through the body. The contrast obtained from traditional radiography can be rather poor, particularly when it comes to soft tissue. A wide range of media of interest in materials science, biology and medicine exhibit very weak absorption contrast, but they nevertheless produce significant phase shifts with X-rays. The use of phase information for imaging purposes is therefore an attractive prospect. Some of the X-ray phase-contrast imaging methods require highly monochromatic plane wave radiation and sophisticated X-ray optics. However, the propagation-based phase-contrast imaging method adapted in this paper is a relatively simple method to implement, essentially requiring only a microfocal X-ray tube and electronic detection. In this paper, we present imaging results obtained from two different benchtop X-ray sources employing the free space propagation method. X-ray phase-contrast imaging provides higher contrast in many samples, including biological tissues that have negligible absorption contrast.

  14. Using the phase-space imager to analyze partially coherent imaging systems: bright-field, phase contrast, differential interference contrast, differential phase contrast, and spiral phase contrast

    Science.gov (United States)

    Mehta, Shalin B.; Sheppard, Colin J. R.

    2010-05-01

    Various methods that use large illumination aperture (i.e. partially coherent illumination) have been developed for making transparent (i.e. phase) specimens visible. These methods were developed to provide qualitative contrast rather than quantitative measurement-coherent illumination has been relied upon for quantitative phase analysis. Partially coherent illumination has some important advantages over coherent illumination and can be used for measurement of the specimen's phase distribution. However, quantitative analysis and image computation in partially coherent systems have not been explored fully due to the lack of a general, physically insightful and computationally efficient model of image formation. We have developed a phase-space model that satisfies these requirements. In this paper, we employ this model (called the phase-space imager) to elucidate five different partially coherent systems mentioned in the title. We compute images of an optical fiber under these systems and verify some of them with experimental images. These results and simulated images of a general phase profile are used to compare the contrast and the resolution of the imaging systems. We show that, for quantitative phase imaging of a thin specimen with matched illumination, differential phase contrast offers linear transfer of specimen information to the image. We also show that the edge enhancement properties of spiral phase contrast are compromised significantly as the coherence of illumination is reduced. The results demonstrate that the phase-space imager model provides a useful framework for analysis, calibration, and design of partially coherent imaging methods.

  15. Quantum thermodynamics of the resonant-level model with driven system-bath coupling

    Science.gov (United States)

    Haughian, Patrick; Esposito, Massimiliano; Schmidt, Thomas L.

    2018-02-01

    We study nonequilibrium thermodynamics in a fermionic resonant-level model with arbitrary coupling strength to a fermionic bath, taking the wide-band limit. In contrast to previous theories, we consider a system where both the level energy and the coupling strength depend explicitly on time. We find that, even in this generalized model, consistent thermodynamic laws can be obtained, up to the second order in the drive speed, by splitting the coupling energy symmetrically between system and bath. We define observables for the system energy, work, heat, and entropy, and calculate them using nonequilibrium Green's functions. We find that the observables fulfill the laws of thermodynamics, and connect smoothly to the known equilibrium results.

  16. Contrast-enhanced voiding urosonography: in vitro evaluation of a second-generation ultrasound contrast agent for in vivo optimization.

    Science.gov (United States)

    Back, Susan J; Edgar, J Christopher; Canning, Douglas A; Darge, Kassa

    2015-09-01

    Pediatric contrast-enhanced ultrasound (CEUS) is primarily performed outside the United States where a track record for safety in intravenous and intravesical applications has been established. Contrast-enhanced voiding urosonography (ceVUS) has also been shown to have a much higher rate of vesicoureteral reflux detection compared to voiding cystourethrography. US contrast agents available in the United States differ from those abroad. Optison® (GE Healthcare, Princeton, NJ) is such an US contrast agent. While Optison® has similar characteristics to other second-generation agents, it has never been used for ceVUS. In vitro optimization of dose and imaging parameters as well as assessment of contrast visualization when delivered in conditions similar to ceVUS are necessary starting points prior to in vivo applications. To optimize the intravesical use of Optison® in vitro for ceVUS before its use in pediatric studies. The experimental design simulated intravesical use. Using 9- and 12-MHz linear transducers, we scanned 20-mL syringes varying mechanical index, US contrast agent concentration (0.25%, 0.5%, 1.0%), solvent (saline, urine, radiographic contrast agent) and time out of refrigeration. We evaluated mechanical index settings and contrast duration, optimized the contrast dose, measured the effect of urine and radiographic contrast agent, and the impact of length of time of contrast outside of the refrigerator on US contrast appearance. We scanned 50-ml saline bags to assess the appearance and duration of US contrast with different delivery systems (injection vs. infusion). Consistent contrast visualization was achieved at a mechanical index of 0.06-0.17 and 0.11-0.48 for the L9 and L12 MHz transducers (P contrast visualization of the microbubbles with a higher transducer frequency. The lowest mechanical index for earliest visible microbubble destruction was 0.21 for the 9 MHz and 0.39 for the 12 MHz (P contrast agent volume to bladder filling was the

  17. MR-cholangiography with a double contrast technique

    International Nuclear Information System (INIS)

    Hemmingsson, A.; Carlsten, J.; Ericsson, A.; Holtz, E.; Klaveness, J.; Loennemark, M.; Nyman, R.

    1989-01-01

    The combination of superparamagnetic particles (SPP) as a ''negative'' contrast agent for the liver parenchyma and Cr-HIDA as a ''positive'' one for the bile ducts was tested in dogs. The maximum effect of SPP was present about 30 minutes after injection with a reduction of the image intensity of the liver close to the background noise level at the highest dosages. This effect lasted for about 4 to 5 hours and it had disappeared after 24 hours. Before any contrast administration or after Cr-HIDA the bile ducts were not discernible, but a high signal in the gallbladder was present 15 to 30 minutes after injection of Cr-HIDA. After SPP the wider bile ducts were discernible because of the lowering of the signal intensity in the liver. When SPP were followed by Cr-HIDA, the bile had a higher signal intensity, and even tiny bile ducts were visible. After cholecystokinin visualization of the choledochus duct was achieved as well as contrast filling of the duodenum. The blood, urine and liver function tests were found normal during the experiments. The combination of superparamagnetic particles and Cr-HIDA seems to be a promising method for MR-cholangiography. An evaluation of the anatomic structures of the liver should be possible with this method in different pathologies. (orig.)

  18. Arterial Spin Labeling and Blood Oxygen Level-Dependent MRI Cerebrovascular Reactivity in Cerebrovascular Disease

    DEFF Research Database (Denmark)

    Smeeing, Diederik P J; Hendrikse, Jeroen; Petersen, Esben T

    2016-01-01

    BACKGROUND: The cerebrovascular reactivity (CVR) results of blood oxygen level-dependent (BOLD) and arterial spin labeling (ASL) MRI studies performed in patients with cerebrovascular disease (steno-occlusive vascular disease or stroke) were systematically reviewed. SUMMARY: Thirty-one articles...... found a significant lower ASL CVR in the ipsilateral hemispheres of patients compared to controls. KEY MESSAGES: This review brings support for a reduced BOLD and ASL CVR in the ipsilateral hemisphere of patients with cerebrovascular disease. We suggest that future studies will be performed in a uniform...... way so reference values can be established and could be used to guide treatment decisions in patients with cerebrovascular disease....

  19. A contrast enhancement method for improving the segmentation of breast lesions on ultrasonography.

    Science.gov (United States)

    Flores, Wilfrido Gómez; Pereira, Wagner Coelho de Albuquerque

    2017-01-01

    This paper presents an adaptive contrast enhancement method based on sigmoidal mapping function (SACE) used for improving the computerized segmentation of breast lesions on ultrasound. First, from the original ultrasound image an intensity variation map is obtained, which is used to generate local sigmoidal mapping functions related to distinct contextual regions. Then, a bilinear interpolation scheme is used to transform every original pixel to a new gray level value. Also, four contrast enhancement techniques widely used in breast ultrasound enhancement are implemented: histogram equalization (HEQ), contrast limited adaptive histogram equalization (CLAHE), fuzzy enhancement (FEN), and sigmoid based enhancement (SEN). In addition, these contrast enhancement techniques are considered in a computerized lesion segmentation scheme based on watershed transformation. The performance comparison among techniques is assessed in terms of both the quality of contrast enhancement and the segmentation accuracy. The former is quantified by the measure, where the greater the value, the better the contrast enhancement, whereas the latter is calculated by the Jaccard index, which should tend towards unity to indicate adequate segmentation. The experiments consider a data set with 500 breast ultrasound images. The results show that SACE outperforms its counterparts, where the median values for the measure are: SACE: 139.4, SEN: 68.2, HEQ: 64.1, CLAHE: 62.8, and FEN: 7.9. Considering the segmentation performance results, the SACE method presents the largest accuracy, where the median values for the Jaccard index are: SACE: 0.81, FEN: 0.80, CLAHE: 0.79, HEQ: 77, and SEN: 0.63. The SACE method performs well due to the combination of three elements: (1) the intensity variation map reduces intensity variations that could distort the real response of the mapping function, (2) the sigmoidal mapping function enhances the gray level range where the transition between lesion and background

  20. Simulation of design dependent failure exposure levels for CMOS ICs

    International Nuclear Information System (INIS)

    Kaul, N.; Bhuva, B.L.; Rangavajjhala, V.; van der Molen, H.; Kerns, S.E.

    1990-01-01

    The total dose exposure of CMOS ICs introduces bias-dependent parameter shifts in individual devices. The bias dependency of individual parameter shifts of devices cause different designs to behave differently under identical testing conditions. This paper studies the effect of design and bias on the radiation tolerance of ICs and presents an automated design tool that produces different designs for a logic function, and presents important parameters of each design to circuit designer for trade off analysis

  1. The clinical use of contrast agents in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Bydder, G.M.

    1987-01-01

    Interest in the use of external agents to increase tissue contrasts has come from many sources dating back to the earliest work in NMR, to animal studies and to the widespread use of contrast agents in conventional radiological practice. The first clinical magnetic resonance images were published in 1980 and in the following year a brief account of the use of the paramagnetic agents in human volunteers was established. It was apparent relatively early in the development of magnetic resonance imaging (MRI) that a high level of soft tissue contrast was available de novo and the need for externally administered agents might therefore be small. This observation was tempered by the fact that separation of tumour from oedema was frequently better with contrast enhanced CT X-ray than with unenhanced MRI and that of a contrast agent might therefore be needed for MRI. At the end of 1983 the first parenteral agent gadoliminum diethylene triamine pentaacetic acid (Gd-DTPA) was used in volunteers and clinical studies began in 1984. At the present time only molecular O/sub 2/, oral iron compounds and Gd-DTPA are in clinical use although there are a number of other agents which have been used in animals and some of these may become available for clinical use in the foreseeable future

  2. Simulating Visibility Under Reduced Acuity and Contrast Sensitivity

    Science.gov (United States)

    Thompson, William B.; Legge, Gordon E.; Kersten, Daniel J.; Shakespeare, Robert A.; Lei, Quan

    2017-01-01

    Architects and lighting designers have difficulty designing spaces that are accessible to those with low vision, since the complex nature of most architectural spaces requires a site-specific analysis of the visibility of mobility hazards and key landmarks needed for navigation. We describe a method that can be utilized in the architectural design process for simulating the effects of reduced acuity and contrast on visibility. The key contribution is the development of a way to parameterize the simulation using standard clinical measures of acuity and contrast sensitivity. While these measures are known to be imperfect predictors of visual function, they provide a way of characterizing general levels of visual performance that is familiar to both those working in low vision and our target end-users in the architectural and lighting design communities. We validate the simulation using a letter recognition task. PMID:28375328

  3. Noise and contrast detection in computed tomography images

    International Nuclear Information System (INIS)

    Faulkner, K.; Moores, B.M.

    1984-01-01

    A discrete representation of the reconstruction process is used in an analysis of noise in computed tomography (CT) images. This model is consistent with the method of data collection in actual machines. An expression is derived which predicts the variance on the measured linear attenuation coefficient of a single pixel in an image. The dependence of the variance on various CT scanner design parameters such as pixel size, slice width, scan time, number of detectors, etc., is then described. The variation of noise with sampling area is theoretically explained. These predictions are in good agreement with a set of experimental measurements made on a range of CT scanners. The equivalent sampling aperture of the CT process is determined and the effect of the reconstruction filter on the variance of the linear attenuation coefficient is also noted, in particular, the choice and its consequences for reconstructed images and noise behaviour. The theory has been extended to include contrast detail behaviour, and these predictions compare favourably with experimental measurements. The theory predicts that image smoothing will have little effect on the contrast-detail detectability behaviour of reconstructed images. (author)

  4. Analysis of contact stiffness in ultrasound atomic force microscopy: three-dimensional time-dependent ultrasound modeling

    International Nuclear Information System (INIS)

    Piras, Daniele; Sadeghian, Hamed

    2017-01-01

    Ultrasound atomic force microscopy (US-AFM) has been used for subsurface imaging of nanostructures. The contact stiffness variations have been suggested as the origin of the image contrast. Therefore, to analyze the image contrast, the local changes in the contact stiffness due to the presence of subsurface features should be calculated. So far, only static simulations have been conducted to analyze the local changes in the contact stiffness and, consequently, the contrast in US-AFM. Such a static approach does not fully represent the real US-AFM experiment, where an ultrasound wave is launched either into the sample or at the tip, which modulates the contact stiffness. This is a time-dependent nonlinear dynamic problem rather than a static and stationary one. This paper presents dynamic 3D ultrasound analysis of contact stiffness in US-AFM (in contrast to static analysis) to realistically predict the changes in contact stiffness and thus the changes in the subsurface image contrast. The modulation frequency also influences the contact stiffness variations and, thus, the image contrast. The three-dimensional time-dependent ultrasound analysis will greatly aid in the contrast optimization of subsurface nano imaging with US-AFM. (paper)

  5. Selective and context-dependent effects of chemical stress across trophic levels at the basis of marine food webs.

    Science.gov (United States)

    Mensens, Christoph; De Laender, Frederik; Janssen, Colin R; Rivera, Frances Camille; Sabbe, Koen; De Troch, Marleen

    2018-04-26

    Human activities increasingly impact the functioning of marine food webs, but anthropogenic stressors are seldom included in ecological study designs. Diet quality, as distinct from just diet quantity, has moreover rarely been highlighted in food web studies in a stress context. We measured the effects of metal and pesticide stress (copper and atrazine) on the contribution of a benthic intertidal diatom community to two processes that are key to the functioning of intertidal systems: biomass (diet quantity) and lipid (diet quality) production. We then examined if stressors affected diatom functioning by selectively targeting the species contributing most to functioning (selective stress effects) or by changing the species' functional contribution (context-dependent effects). Finally, we tested if stress-induced changes in diet quality altered the energy flow to the diatoms' main grazers (harpacticoid copepods). Diatom diet quantity was reduced by metal stress but not by low pesticide levels due to the presence of an atrazine-tolerant, mixotrophic species. Selective effects of the pesticide reduced diatom diet quality by 60% and 75% at low and high pesticide levels respectively, by shifting diatom community structure from dominance by lipid-rich species toward dominance by an atrazine-tolerant, but lipid-poor, species. Context-dependent effects did not affect individual diatom lipid content at low levels of both stressors, but caused diatoms to lose 40% of their lipids at high copper stress. Stress-induced changes in diet quality predicted the energy flow from the diatoms to their copepod consumers, which lost half of their lipids when feeding on diatoms grown under low and high pesticide and high metal stress. Selective pesticide effects were a more important threat for trophic energy transfer than context-dependent effects of both stressors, with shifts in diatom community structure affecting the energy flow to their copepod grazers at stress levels where no

  6. Chromatic spatial contrast sensitivity estimated by visual evoked cortical potential and psychophysics

    Science.gov (United States)

    Barboni, M.T.S.; Gomes, B.D.; Souza, G.S.; Rodrigues, A.R.; Ventura, D.F.; Silveira, L.C.L.

    2013-01-01

    The purpose of the present study was to measure contrast sensitivity to equiluminant gratings using steady-state visual evoked cortical potential (ssVECP) and psychophysics. Six healthy volunteers were evaluated with ssVECPs and psychophysics. The visual stimuli were red-green or blue-yellow horizontal sinusoidal gratings, 5° × 5°, 34.3 cd/m2 mean luminance, presented at 6 Hz. Eight spatial frequencies from 0.2 to 8 cpd were used, each presented at 8 contrast levels. Contrast threshold was obtained by extrapolating second harmonic amplitude values to zero. Psychophysical contrast thresholds were measured using stimuli at 6 Hz and static presentation. Contrast sensitivity was calculated as the inverse function of the pooled cone contrast threshold. ssVECP and both psychophysical contrast sensitivity functions (CSFs) were low-pass functions for red-green gratings. For electrophysiology, the highest contrast sensitivity values were found at 0.4 cpd (1.95 ± 0.15). ssVECP CSF was similar to dynamic psychophysical CSF, while static CSF had higher values ranging from 0.4 to 6 cpd (P chromatic functions showed no specific tuning shape; however, at high spatial frequencies the evoked potentials showed higher contrast sensitivity than the psychophysical methods (P chromatic red-green CSFs in agreement with psychophysical thresholds, mainly if the same temporal properties are applied to the stimulus. For blue-yellow CSF, correlation between electrophysiology and psychophysics was poor at high spatial frequency, possibly due to a greater effect of chromatic aberration on this kind of stimulus. PMID:23369980

  7. How contrast situations affect the assignment of causality in symmetric physical settings.

    Science.gov (United States)

    Beller, Sieghard; Bender, Andrea

    2014-01-01

    In determining the prime cause of a physical event, people often weight one of two entities in a symmetric physical relation as more important for bringing about the causal effect than the other. In a broad survey (Bender and Beller, 2011), we documented such weighting effects for different kinds of physical events and found that their direction and strength depended on a variety of factors. Here, we focus on one of those: adding a contrast situation that-while being formally irrelevant-foregrounds one of the factors and thus frames the task in a specific way. In two experiments, we generalize and validate our previous findings by using different stimulus material (in Experiment 1), by applying a different response format to elicit causal assignments, an analog rating scale instead of a forced-choice decision (in Experiment 2), and by eliciting explanations for the physical events in question (in both Experiments). The results generally confirm the contrast effects for both response formats; however, the effects were more pronounced with the force-choice format than with the rating format. People tended to refer to the given contrast in their explanations, which validates our manipulation. Finally, people's causal assignments are reflected in the type of explanation given in that contrast and property explanations were associated with biased causal assignments, whereas relational explanations were associated with unbiased assignments. In the discussion, we pick up the normative questions of whether or not these contrast effects constitute a bias in causal reasoning.

  8. Contrast media in gall bladder diagnostics

    International Nuclear Information System (INIS)

    Schindler, G.; Frommhold, W.

    1982-01-01

    The justification of conventional X-ray diagnostic of bile ducts is repeatedly questioned by newer examination techniques like sonography and ERC. The indication for oral cholesgraphy is derived from its high-specifity of its statements for gall bladder diagnostic, that is as high as with sonography and does not depend on the experience of the investigator. The importance of the the void exposure is undoubted with correspondence of medicamentary litholysis for calcite identification. Furthermore, Choleocystic kineticals like Ceruletid let recognize better hyper plastic choleocysts like adenomyomatoses. The intravenous choleocyst-cholangiography posesses a clearly limited indication scheme even after introduction of sonography and ERC. The infusion method yields a better compatibility of the contrast medium with a simultaneous increased representation quality of the bile duct, that can be increased by a consequent application of the layer exposure technique. (orig.) [de

  9. Preprocedural Prediction Model for Contrast-Induced Nephropathy Patients.

    Science.gov (United States)

    Yin, Wen-Jun; Yi, Yi-Hu; Guan, Xiao-Feng; Zhou, Ling-Yun; Wang, Jiang-Lin; Li, Dai-Yang; Zuo, Xiao-Cong

    2017-02-03

    Several models have been developed for prediction of contrast-induced nephropathy (CIN); however, they only contain patients receiving intra-arterial contrast media for coronary angiographic procedures, which represent a small proportion of all contrast procedures. In addition, most of them evaluate radiological interventional procedure-related variables. So it is necessary for us to develop a model for prediction of CIN before radiological procedures among patients administered contrast media. A total of 8800 patients undergoing contrast administration were randomly assigned in a 4:1 ratio to development and validation data sets. CIN was defined as an increase of 25% and/or 0.5 mg/dL in serum creatinine within 72 hours above the baseline value. Preprocedural clinical variables were used to develop the prediction model from the training data set by the machine learning method of random forest, and 5-fold cross-validation was used to evaluate the prediction accuracies of the model. Finally we tested this model in the validation data set. The incidence of CIN was 13.38%. We built a prediction model with 13 preprocedural variables selected from 83 variables. The model obtained an area under the receiver-operating characteristic (ROC) curve (AUC) of 0.907 and gave prediction accuracy of 80.8%, sensitivity of 82.7%, specificity of 78.8%, and Matthews correlation coefficient of 61.5%. For the first time, 3 new factors are included in the model: the decreased sodium concentration, the INR value, and the preprocedural glucose level. The newly established model shows excellent predictive ability of CIN development and thereby provides preventative measures for CIN. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  10. Comparison of excretory urographic contrast effects of dimeric and monomeric non-ionic iodinated contrast media in dogs

    International Nuclear Information System (INIS)

    Kishimoto, M.; Yamada, K.; Watanabe, A.; Miyamoto, K.; Iwasaki, T.; Miyake, Y.

    2007-01-01

    In excretory urography, the osmolarity of contrast media has rarely been treated as important in veterinary medicine. In this study, the contrast effect of two contrast media (monomeric iohexol and dimeric iodixanol) in the renal cortex and aorta were compared using computed tomography (CT). Five beagle dogs were used and the study employed a cross-over method for each contrast media. The results showed that there was no difference between the media in the aorta, but iodixanol showed higher CT value and a longer contrast effect than iohexol in the renal cortex, in spite of having the same iodine dosage. It is believed that iodixanol, with its low osmolarity, is diluted less by osmotic diuresis than monomeric iohexol. It is important to consider the osmolarity of the contrast media when evaluating the contrast effect, and it is essential to use the same contrast media for each examination, or the renal excretory speed will be under/overestimated

  11. Adriamycin nephrosis and contrast media

    International Nuclear Information System (INIS)

    Thomsen, H.S.; Golman, K.; Hemmingsen, L.; Larsen, S.; Skaarup, P.; Koebenhavns Amts Sygehus, Herlev; Koebenhavns Amts Sygehus, Herlev; Centralsygehuset, Nykoebing Falster; Malmoe Allmaenna Sjukhus

    1990-01-01

    Urine profiles (albumin, glucose, NAG, LDH, GGT and sodium) were followed for 9 days after intravenous injection of either diatrizoate, iohexol, or saline in 27 Wistar rats with nephrosis induced by Adriamycin 42 days before. Another 9 rats exposed to neither Adriamycin nor contrast media served as controls. None of the contrast media caused further increased albuminuria of significance, whereas both induced significantly increased excretion of all 5 tubular components. The excretion of NAG and sodium was significantly higher following diatrizoate than following iohexol. From 24 h post injection there was no significantly greater excretion of any of the components after either diatrizoate or iohexol than after saline among the rats given Adriamycin. At the end of day 9 after contrast medium injection neither serum sodium, potassium, glucose, urea, creatinine, nor albumin revealed any contrast media related changes. Kidney histology showed quantitatively larger lesions in kidneys exposed to Adriamycin and contrast media than in kidneys exposed to Adriamycin and saline. There were no differences between the two contrast media groups. It is thus concluded, that both high osmolar ionic and low osmolar non-ionic contrast media cause temporary tubular dysfunction but no further glomerular dysfunction in rats with nephrosis induced by Adriamycin. The histologic findings indicate that both media may worsen non-reversible renal lesions. (orig.)

  12. Delayed rectifier K channels contribute to contrast adaptation in mammalian retinal ganglion cells

    Science.gov (United States)

    Weick, Michael; Demb, Jonathan B.

    2011-01-01

    SUMMARY Retinal ganglion cells adapt by reducing their sensitivity during periods of high contrast. Contrast adaptation in the firing response depends on both presynaptic and intrinsic mechanisms. Here, we investigated intrinsic mechanisms for contrast adaptation in OFF Alpha ganglion cells in the in vitro guinea pig retina. Using either visual stimulation or current injection, we show that brief depolarization evoked spiking and suppressed firing during subsequent depolarization. The suppression could be explained by Na channel inactivation, as shown in salamander cells. However, brief hyperpolarization in the physiological range (5–10 mV) also suppressed firing during subsequent depolarization. This suppression was sensitive selectively to blockers of delayed-rectifier K channels (KDR). Somatic membrane patches showed TEA-sensitive KDR currents with activation near −25 mV and removal of inactivation at voltages negative to Vrest. Brief periods of hyperpolarization apparently remove KDR inactivation and thereby increase the channel pool available to suppress excitability during subsequent depolarization. PMID:21745646

  13. Y-chromosomal diversity in Haiti and Jamaica: contrasting levels of sex-biased gene flow.

    Science.gov (United States)

    Simms, Tanya M; Wright, Marisil R; Hernandez, Michelle; Perez, Omar A; Ramirez, Evelyn C; Martinez, Emanuel; Herrera, Rene J

    2012-08-01

    Although previous studies have characterized the genetic structure of populations from Haiti and Jamaica using classical and autosomal STR polymorphisms, the patrilineal influences that are present in these countries have yet to be explored. To address this lacuna, the current study aims to investigate, for the first time, the potential impact of different ancestral sources, unique colonial histories, and distinct family structures on the paternal profile of both groups. According to previous reports examining populations from the Americas, island-specific demographic histories can greatly impact population structure, including various patterns of sex-biased gene flow. Also, given the contrasting autosomal profiles provided in our earlier study (Simms et al.: Am J Phys Anthropol 142 (2010) 49-66), we hypothesize that the degree and directionality of gene flow from Europeans, Africans, Amerindians, and East Asians are dissimilar in the two countries. To test this premise, 177 high-resolution Y-chromosome binary markers and 17 Y-STR loci were typed in Haiti (n = 123) and Jamaica (n = 159) and subsequently utilized for phylogenetic comparisons to available reference collections encompassing Africa, Europe, Asia (East and South), and the New World. Our results reveal that both studied populations exhibit a predominantly South-Saharan paternal component, with haplogroups A1b-V152, A3-M32, B2-M182, E1a-M33, E1b1a-M2, E2b-M98, and R1b2-V88 comprising 77.2% and 66.7% of the Haitian and Jamaican paternal gene pools, respectively. Yet, European derived chromosomes (i.e., haplogroups G2a*-P15, I-M258, R1b1b-M269, and T-M184) were detected at commensurate levels in Haiti (20.3%) and Jamaica (18.9%), whereas Y-haplogroups indicative of Chinese [O-M175 (3.8%)] and Indian [H-M69 (0.6%) and L-M20 (0.6%)] ancestry were restricted to Jamaica. Copyright © 2012 Wiley Periodicals, Inc.

  14. Protocol dependence of mechanical properties in granular systems.

    Science.gov (United States)

    Inagaki, S; Otsuki, M; Sasa, S

    2011-11-01

    We study the protocol dependence of the mechanical properties of granular media by means of computer simulations. We control a protocol of realizing disk packings in a systematic manner. In 2D, by keeping material properties of the constituents identical, we carry out compaction with various strain rates. The disk packings exhibit the strain rate dependence of the critical packing fraction above which the pressure becomes non-zero. The observed behavior contrasts with the well-studied jamming transitions for frictionless disk packings. We also observe that the elastic moduli of the disk packings depend on the strain rate logarithmically. Our results suggest that there exists a time-dependent state variable to describe macroscopic material properties of disk packings, which depend on its protocol.

  15. Caregivers of patients with cancer: anxiety, depression and distribution of dependency.

    Science.gov (United States)

    Cipolletta, Sabrina; Shams, Malihe; Tonello, Fabio; Pruneddu, Alessandra

    2013-01-01

    Assisting a patient with cancer implies assuming a role that may fit in with the previous role of the person or that may contrast with it, thereby provoking suffering. This research explores if it is possible to identify different profiles of caregivers on the basis of different levels of anxiety and depression as well as on different ways of distributing one's own dependency. There were 50 Italian primary caregivers of patients with cancer who completed the Beck Anxiety Inventory, the Beck Depression Inventory-II, and Kelly's Dependency Grids. Cluster analysis was conducted on the indices derived from the three instruments. Three profiles were found on the basis of how the caregivers used their resources to give and to receive help. If there was congruence between the situation of giving help that the caregivers experienced and their personal role, then anxiety and depression decreased, otherwise, they increased. The implications of the balance/imbalance between the usual and the present role depended also on the typicality of the caregivers' experience, as related to their caring role. These results suggest the usefulness of planning different kinds of support for different experiences of caregiving. Copyright © 2011 John Wiley & Sons, Ltd.

  16. Contrast settling in cerebral aneurysm angiography

    International Nuclear Information System (INIS)

    Wang Zhijie; Hoffmann, Kenneth R; Guterman, Lee R; Wang Zhou; Rudin, Stephen; Meng Hui

    2005-01-01

    During angiography, blood flow is visualized with a radiopaque contrast agent, which is denser than blood. In complex vasculature, such as cerebral saccular aneurysms, the density difference may produce an appreciable gravity effect, where the contrast material separates from blood and settles along the gravity direction. Although contrast settling has been occasionally reported before, the fluid mechanics behind it have not been explored. Furthermore, the severity of contrast settling in cerebral aneurysms varies significantly from case to case. Therefore, a better understanding of the physical principles behind this phenomenon is needed to evaluate contrast settling in clinical angiography. In this study, flow in two identical groups of sidewall aneurysm models with varying parent-vessel curvature was examined by angiography. Intravascular stents were deployed into one group of the models. To detect contrast settling, we used lateral view angiography. Time-intensity curves were analysed from the angiographic data, and a computational fluid dynamic analysis was conducted. Results showed that contrast settling was strongly related to the local flow dynamics. We used the Froude number, a ratio of flow inertia to gravity force, to characterize the significance of gravity force. An aneurysm with a larger vessel curvature experienced higher flow, which resulted in a larger Froude number and, thus, less gravitational settling. Addition of a stent reduced the aneurysmal flow, thereby increasing the contrast settling. We found that contrast settling resulted in an elevated washout tail in the time-intensity curve. However, this signature is not unique to contrast settling. To determine whether contrast settling is present, a lateral view should be obtained in addition to the anteroposterior (AP) view routinely used clinically so as to rule out contrast settling and hence to enable a valid time-intensity curve analysis of blood flow in the aneurysm

  17. Parent-child feedback predicts sibling contrast: using twin studies to test theories of parent-offspring interaction in infant behavior.

    Science.gov (United States)

    Eaves, Lindon J; Silberg, Judy L

    2005-02-01

    Several studies report apparent sibling contrast effects in analyses of twin resemblance. In the presence of genetic differences, contrast effects reduce the dizygotic (DZ) twin correlation relative to that in monozygotic (MZ) twins and produce higher DZ than MZ variance. Explanations of contrast effects are typically cast in terms of direct social interaction between twins or an artifact of the process of rating children by their parents. We outline a model for sibling imitation and contrast effects that depends on social interaction between parents and children. In addition to predicting the observed pattern of twin variances and covariances, the parental mediation of child imitation and contrast effects leads to differences in the variance of parents of MZ and DZ twins and differences between the correlations of parents with their MZ and DZ children.

  18. Sporadic insulinomas on volume perfusion CT: dynamic enhancement patterns and timing of optimal tumour-parenchyma contrast

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Liang; Xue, Hua-dan; Liu, Wei; Wang, Xuan; Sun, Hao; Li, Ping; Jin, Zheng-yu [Peking Union Medical College Hospital, Department of Radiology, Beijing (China); Wu, Wen-ming; Zhao, Yu-pei [Peking Union Medical College Hospital, Department of General Surgery, Beijing (China)

    2017-08-15

    To assess enhancement patterns of sporadic insulinomas on volume perfusion CT (VPCT), and to identify timing of optimal tumour-parenchyma contrast. Consecutive patients who underwent VPCT for clinically suspected insulinomas were retrospectively identified. Patients with insulinomas confirmed by surgery were included, and patients with familial syndromes were excluded. Two radiologists evaluated VPCT images in consensus. Tumour-parenchyma contrast at each time point was measured, and timing of optimal contrast was determined. Time duration of hyperenhancement (tumour-parenchyma contrast >20 Hounsfield units, HU) was recorded. Perfusion parameters were evaluated. Three dynamic enhancement patterns were observed in 63 tumours: persistent hyperenhancement (hyperenhancement time window ≥10 s) in 39 (61.9%), transient hyperenhancement (hyperenhancement <10 s) in 19 (30.2%) and non-hyperenhancement in 5 (7.9%). Timing of optimal contrast was 9 s after abdominal aorta threshold (AAT) of 200 HU, with tumour-parenchyma contrast of 77.6 ± 57.2 HU. At 9 s after AAT, 14 (22.2%) tumours were non-hyperenhancing, nine of which had missed transient hyperenhancement. Insulinomas with transient and persistent hyperenhancement patterns had significantly increased perfusion. Insulinomas have variable enhancement patterns. Tumour-parenchyma contrast is time-dependent. Optimal timing of enhancement is 9 s after AAT. VPCT enables tumour detection even if the hyperenhancement is transient. (orig.)

  19. Costo-efectividad de medios de contraste isoosmolales e hiposmolales en pacientes con alto riesgo de nefropatía inducida por medio de contraste

    Directory of Open Access Journals (Sweden)

    Liliana Alejandra Chicaíza-Becerra

    2012-06-01

    Full Text Available Introducción. Los medios de contraste pueden provocar falla renal aguda por toxicidad directa sobre las células tubulares e isquemia medular renal. Los pacientes diabéticos y los hospitalizados presentan mayor riesgo de desarrollar nefropatía inducida por medios de contraste que la población general. Objetivo. Establecer el costo-efectividad de los medios de contraste isosmolales e hiposmolales en pacientes con alto riesgo. Materiales and métodos. El análisis se basó en una revisión sistemática de la literatura científica, comparando los efectos nefrotóxicos de los medios isosmolales e hipoosmolales. Se consideraron sólo los costos directos, obtenidos del manual tarifario. Se calcularon las tasas del incremento del costoefectividad, las curvas de eficiencia y de aceptabilidad. Se hicieron análisis univariados de sensibilidad para costos y efectos, así como probabilísticos. Se aplicaron tasas de descuento de 0 y 3 % a losresultados. Se usó como umbral de costo-efectividad por año de vida ganado, el producto interno bruto per cápita. Resultados. Las alternativas con Iopamidol y Iodixanol dominan a las demás porque reducen el riesgo de nefropatía inducida por contraste a un menor costo. La razón del incremento del costo-efectividad del iodixanol comparado con el iopamidol es de US$ 14.660 por año de vida ganado que más que duplica el umbral. Conclusión. El medio de baja osmolalidad, iopamidol, parece ser costo-efectivo comparado con iohexol u otros medios hiposmolares (iopromide, iobitridol, iomeprol, iopentol y ioxilan, en pacientes con alto riesgo de nefropatía inducida por contraste. La elección del medio hiposmolar, depende de la disponibilidad a pagar o del costo por ampolleta.   doi: http://dx.doi.org/10.7705/biomedica.v32i2.367

  20. Effects of detomidine on equine oesophageal function as studied by contrast radiography

    International Nuclear Information System (INIS)

    Watson, T.D.G.; Sullivan, M.

    1991-01-01

    The effects of sedation with detomidine on oesophageal function were assessed by contrast radiography in 10 healthy adult thoroughbred horses. Barium swallows were monitored by means of image intensification, first without sedation and then after the intravenous administration of detomidine at doses of 10 and 20 micrograms/kg bodyweight. The transit time of contrast agent to the oesophageal hiatus was recorded and each swallow was scored for markers of oesophageal dysfunction. Analysis of the data indicated that there were highly significant dose dependent increases in the transit time, the retention of barium within the longitudinal mucosal folds, and retrograde peristalsis and pooling of contrast agent within the oesophagus at both the thoracic inlet and caudal to the base of the heart. The degree of gastrooesophageal reflux was not affected at either dosage. These changes in oesophageal function were similar to those recorded from cases of grass sickness and indicate that care should be taken in the interpretation of studies of swallowing in animals that have been given detomidine before a radiographic examination

  1. Illuminating a neglected clinical issue: societal costs of interpersonal dependency and dependent personality disorder.

    Science.gov (United States)

    Bornstein, Robert F

    2012-07-01

    To determine the degree to which patients with high levels of trait dependency or dependent personality disorder (DPD) engage in behaviors that harm themselves and others (e.g., domestic violence, child abuse). Six domains of literature were reviewed: (a) dependency as a risk factor for physical illness; (b) health care utilization and expenditures; (c) global and domain-specific functional impairment; (d) violence toward others; (e) victimization by others; and (f) self-harm. High levels of trait dependency and DPD are associated with elevated risk for physical illness, partner and child abuse, and suicidality, as well as with high levels of functional impairment and increased health care expenditure. Contrary to clinical lore, trait dependency and DPD are associated with behaviors that lead to myriad negative consequences for the dependent person, those close to them, and society as a whole. These patterns have noteworthy implications for assessment and treatment of dependent patients and suggest that DPD should be included as a diagnostic category in the Diagnostic and Statistical Manual of Mental Disorders Fifth Edition. © 2012 Wiley Periodicals, Inc.

  2. Contrast enhanced ultrasound in liver imaging

    International Nuclear Information System (INIS)

    Nielsen, Michael Bachmann; Bang, Nanna

    2004-01-01

    Ultrasound contrast agents were originally introduced to enhance the Doppler signals when detecting vessels with low velocity flow or when imaging conditions were sub-optimal. Contrast agents showed additional properties, it was discovered that a parenchymal enhancement phase in the liver followed the enhancement of the blood pool. Contrast agents have made ultrasound scanning more accurate in detection and characterization of focal hepatic lesions and the sensitivity is now comparable with CT and MRI scanning. Further, analysis of the transit time of contrast agent through the liver seems to give information on possible hepatic involvement, not only from focal lesions but also from diffuse benign parenchymal disease. The first ultrasound contrast agents were easily destroyed by the energy from the sound waves but newer agents have proved to last for longer time and hereby enable real-time scanning and make contrast enhancement suitable for interventional procedures such as biopsies and tissue ablation. Also, in monitoring the effect of tumour treatment contrast agents have been useful. A brief overview is given on some possible applications and on different techniques using ultrasound contrast agents in liver imaging. At present, the use of an ultrasound contrast agent that allows real-time scanning with low mechanical index is to be preferred

  3. Double-stranded DNA-dependent ATPase Irc3p is directly involved in mitochondrial genome maintenance.

    Science.gov (United States)

    Sedman, Tiina; Gaidutšik, Ilja; Villemson, Karin; Hou, YingJian; Sedman, Juhan

    2014-12-01

    Nucleic acid-dependent ATPases are involved in nearly all aspects of DNA and RNA metabolism. Previous studies have described a number of mitochondrial helicases. However, double-stranded DNA-dependent ATPases, including translocases or enzymes remodeling DNA-protein complexes, have not been identified in mitochondria of the yeast Saccharomyces cerevisae. Here, we demonstrate that Irc3p is a mitochondrial double-stranded DNA-dependent ATPase of the Superfamily II. In contrast to the other mitochondrial Superfamily II enzymes Mss116p, Suv3p and Mrh4p, which are RNA helicases, Irc3p has a direct role in mitochondrial DNA (mtDNA) maintenance. Specific Irc3p-dependent mtDNA metabolic intermediates can be detected, including high levels of double-stranded DNA breaks that accumulate in irc3Δ mutants. irc3Δ-related topology changes in rho- mtDNA can be reversed by the deletion of mitochondrial RNA polymerase RPO41, suggesting that Irc3p counterbalances adverse effects of transcription on mitochondrial genome stability. © The Author(s) 2014. Published by Oxford University Press on behalf of Nucleic Acids Research.

  4. MRI and CT contrast media extravasation

    Science.gov (United States)

    Heshmatzadeh Behzadi, Ashkan; Farooq, Zerwa; Newhouse, Jeffery H.; Prince, Martin R.

    2018-01-01

    Abstract Background: This systematic review combines data from multiple papers on contrast media extravasation to identify factors contributing to increased extravasation risk. Methods: Data were extracted from 17 papers reporting 2191 extravasations in 1,104,872 patients (0.2%) undergoing computed tomography (CT) or magnetic resonance imaging (MRI). Results: Extravasation rates were 0.045% for gadolinium-based contrast agents (GBCA) and nearly 6-fold higher, 0.26% for iodinated contrast agents. Factors associated with increased contrast media extravasations included: older age, female gender, using an existing intravenous (IV) instead of placing a new IV in radiology, in-patient status, use of automated power injection, high injection rates, catheter location, and failing to warm up the more viscous contrast media to body temperature. Conclusion: Contrast media extravasation is infrequent but nearly 6 times less frequent with GBCA for MRI compared with iodinated contrast used in CT. PMID:29489663

  5. In which patients should serum creatinine be measured before iodinated contrast medium administration?

    International Nuclear Information System (INIS)

    Thomsen, Henrik S.

    2005-01-01

    Routine measurement of serum creatinine before injection of intravascular iodinated contrast material in all patients would be cumbersome and have an associated cost. There is doubt about whether serum creatinine should be measured routinely in all patients or selectively. The Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and draw up guidelines on this important practical issue. A literature search was carried out and summarized in a report. Based on the available information and discussions amongst the members of the Committee, guidelines were produced. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain. The practice for identifying patients at risk of contrast medium induced nephropathy varies considerably from one institution to another. Patients at risk constitute only a small percentage of all cases referred for contrast enhanced imaging examination. However, it is important to identify them and take the necessary precautions. Recent serum creatinine level should be available in patients with an increased probability of a raised serum creatinine level (renal disease, renal surgery, proteinuria, diabetes mellitus, hypertension, gout, current intake of nephrotoxic drugs). A simple guideline has been produced. (orig.)

  6. In which patients should serum creatinine be measured before iodinated contrast medium administration?

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, Henrik S. [Copenhagen University Hospital, Herlev (Denmark). Department of Diagnostic Radiology; Morcos, Sameh K. [Northern General Hospital, Department of Diagnostic Imaging, Sheffield Teaching Hospitals NHS Trust, Sheffield (United Kingdom)

    2005-04-01

    Routine measurement of serum creatinine before injection of intravascular iodinated contrast material in all patients would be cumbersome and have an associated cost. There is doubt about whether serum creatinine should be measured routinely in all patients or selectively. The Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and draw up guidelines on this important practical issue. A literature search was carried out and summarized in a report. Based on the available information and discussions amongst the members of the Committee, guidelines were produced. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain. The practice for identifying patients at risk of contrast medium induced nephropathy varies considerably from one institution to another. Patients at risk constitute only a small percentage of all cases referred for contrast enhanced imaging examination. However, it is important to identify them and take the necessary precautions. Recent serum creatinine level should be available in patients with an increased probability of a raised serum creatinine level (renal disease, renal surgery, proteinuria, diabetes mellitus, hypertension, gout, current intake of nephrotoxic drugs). A simple guideline has been produced. (orig.)

  7. Human reliability analysis of dependent events

    International Nuclear Information System (INIS)

    Swain, A.D.; Guttmann, H.E.

    1977-01-01

    In the human reliability analysis in WASH-1400, the continuous variable of degree of interaction among human events was approximated by selecting four points on this continuum to represent the entire continuum. The four points selected were identified as zero coupling (i.e., zero dependence), complete coupling (i.e., complete dependence), and two intermediate points--loose coupling (a moderate level of dependence) and tight coupling (a high level of dependence). The paper expands the WASH-1400 treatment of common mode failure due to the interaction of human activities. Mathematical expressions for the above four levels of dependence are derived for parallel and series systems. The psychological meaning of each level of dependence is illustrated by examples, with probability tree diagrams to illustrate the use of conditional probabilities resulting from the interaction of human actions in nuclear power plant tasks

  8. Phase-only optical encryption based on the zeroth-order phase-contrast technique

    Science.gov (United States)

    Pizolato, José Carlos; Neto, Luiz Gonçalves

    2009-09-01

    A phase-only encryption/decryption scheme with the readout based on the zeroth-order phase-contrast technique (ZOPCT), without the use of a phase-changing plate on the Fourier plane of an optical system based on the 4f optical correlator, is proposed. The encryption of a gray-level image is achieved by multiplying the phase distribution obtained directly from the gray-level image by a random phase distribution. The robustness of the encoding is assured by the nonlinearity intrinsic to the proposed phase-contrast method and the random phase distribution used in the encryption process. The experimental system has been implemented with liquid-crystal spatial modulators to generate phase-encrypted masks and a decrypting key. The advantage of this method is the easy scheme to recover the gray-level information from the decrypted phase-only mask applying the ZOPCT. An analysis of this decryption method was performed against brute force attacks.

  9. An improved contrast enhancement algorithm for infrared images based on adaptive double plateaus histogram equalization

    Science.gov (United States)

    Li, Shuo; Jin, Weiqi; Li, Li; Li, Yiyang

    2018-05-01

    Infrared thermal images can reflect the thermal-radiation distribution of a particular scene. However, the contrast of the infrared images is usually low. Hence, it is generally necessary to enhance the contrast of infrared images in advance to facilitate subsequent recognition and analysis. Based on the adaptive double plateaus histogram equalization, this paper presents an improved contrast enhancement algorithm for infrared thermal images. In the proposed algorithm, the normalized coefficient of variation of the histogram, which characterizes the level of contrast enhancement, is introduced as feedback information to adjust the upper and lower plateau thresholds. The experiments on actual infrared images show that compared to the three typical contrast-enhancement algorithms, the proposed algorithm has better scene adaptability and yields better contrast-enhancement results for infrared images with more dark areas or a higher dynamic range. Hence, it has high application value in contrast enhancement, dynamic range compression, and digital detail enhancement for infrared thermal images.

  10. Dual Contrast - Magnetic Resonance Fingerprinting (DC-MRF): A Platform for Simultaneous Quantification of Multiple MRI Contrast Agents.

    Science.gov (United States)

    Anderson, Christian E; Donnola, Shannon B; Jiang, Yun; Batesole, Joshua; Darrah, Rebecca; Drumm, Mitchell L; Brady-Kalnay, Susann M; Steinmetz, Nicole F; Yu, Xin; Griswold, Mark A; Flask, Chris A

    2017-08-16

    Injectable Magnetic Resonance Imaging (MRI) contrast agents have been widely used to provide critical assessments of disease for both clinical and basic science imaging research studies. The scope of available MRI contrast agents has expanded over the years with the emergence of molecular imaging contrast agents specifically targeted to biological markers. Unfortunately, synergistic application of more than a single molecular contrast agent has been limited by MRI's ability to only dynamically measure a single agent at a time. In this study, a new Dual Contrast - Magnetic Resonance Fingerprinting (DC - MRF) methodology is described that can detect and independently quantify the local concentration of multiple MRI contrast agents following simultaneous administration. This "multi-color" MRI methodology provides the opportunity to monitor multiple molecular species simultaneously and provides a practical, quantitative imaging framework for the eventual clinical translation of molecular imaging contrast agents.

  11. Compressive Phase Contrast Tomography

    International Nuclear Information System (INIS)

    Maia, Filipe; MacDowell, Alastair; Marchesini, Stefano; Padmore, Howard A.; Parkinson, Dula Y.; Pien, Jack; Schirotzek, Andre; Yang, Chao

    2010-01-01

    When x-rays penetrate soft matter, their phase changes more rapidly than their amplitude. Interference effects visible with high brightness sources creates higher contrast, edge enhanced images. When the object is piecewise smooth (made of big blocks of a few components), such higher contrast datasets have a sparse solution. We apply basis pursuit solvers to improve SNR, remove ring artifacts, reduce the number of views and radiation dose from phase contrast datasets collected at the Hard X-Ray Micro Tomography Beamline at the Advanced Light Source. We report a GPU code for the most computationally intensive task, the gridding and inverse gridding algorithm (non uniform sampled Fourier transform).

  12. Polymeric nanoparticles as OCT contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Al Rawashdeh, Wa' el [RWTH Aachen University, Experimental Molecular Imaging (Germany); Kray, Stefan [RWTH Aachen University, Institute for Semiconductor Electronics (Germany); Pich, Andrij; Pargen, Sascha; Balaceanu, Andreea [RWTH Aachen University, Interactive Material Research (DWI) (Germany); Lenz, Markus; Spoeler, Felix [RWTH Aachen University, Institute for Semiconductor Electronics (Germany); Kiessling, Fabian, E-mail: fkiessling@ukaachen.de; Lederle, Wiltrud [RWTH Aachen University, Experimental Molecular Imaging (Germany)

    2012-12-15

    In this study, the optical properties of two nano-sized polymer colloids in optical coherence tomography (OCT) were compared in vitro with respect to their potential use as contrast agents. We used two types of particles: compact hydrophobic spherical polystyrene (PS) particles and soft water-swollen nanogel (NG) particles both with grafted hydrophilic shell, both prepared at two different sizes (PS at 300 and 150 nm, NG at 300 and 200 nm). The OCT backscattering signals of the particles in a vessel-mimicking highly scattering agar/TiO{sub 2} phantom were compared on either number of particles or weight percent. Larger particles and higher concentrations produced higher OCT contrast. At each concentration tested, a markedly higher contrast was achieved by PS particles than NG particles. PS particles generated a markedly higher OCT contrast than the phantom at concentrations of at least 1 Multiplication-Sign 10{sup 10} or 0.1 % for PS 300 nm and at least 3 Multiplication-Sign 10{sup 11} particles/mL or 0.4 % for PS 150 nm. The contrast generated by NG 300 nm was above the phantom contrast at concentrations of at least 3 Multiplication-Sign 10{sup 11} particles/mL or 1 %, whereas NG 200 nm only at 4 %. At any given weight percent, the differences in OCT contrast between differently sized particles were much less evident than in the comparison based on particle number. PS 300 nm generated also a good contrast ex vivo on chicken muscle tissue. These results strongly suggest that PS spheres have strong potential as intravascular OCT contrast agent, while NG particles need further contrast enhancer for being used as OCT contrast agent.

  13. Motion contrast using optical coherence tomography

    Science.gov (United States)

    Fingler, Jeffrey Paul

    Diagnosis of ophthalmic diseases like age-related macular degeneration is very important for treatment of the disease as well as the development of future treatments. Optical coherence tomography (OCT) is an optical interference technique which can measure the three-dimensional structural information of the reflecting layers within a sample. In retinal imaging, OCT is used as the primary diagnostic tool for structural abnormalities such as retinal holes and detachments. The contrast within the images of this technique is based upon reflectivity changes from different regions of the retina. This thesis demonstrates the developments of methods used to produce additional contrast to the structural OCT images based on the tiny fluctuations of motion experienced by the mobile scatterers within a sample. Motion contrast was observed for motions smaller than 50 nm in images of a variety of samples. Initial contrast method demonstrations used Brownian motion differences to separate regions of a mobile Intralipid solution from a static agarose gel, chosen in concentration to minimize reflectivity contrast. Zebrafish embryos in the range of 3-4 days post fertilization were imaged using several motion contrast methods to determine the capabilities of identifying regions of vascular flow. Vasculature identification was demonstrated in zebrafish for blood vessels of all orientations as small as 10 microns in diameter. Mouse retinal imaging utilized the same motion contrast methods to determine the contrast capabilities for motions associated with vasculature within the retina. Improved contrast imaging techniques demonstrated comparable images to fluorescein angiography, the gold standard of retinal vascular imaging. Future studies can improve the demonstrated contrast analysis techniques and apply them towards human retinal motion contrast imaging for ophthalmic diagnostic purposes.

  14. A STUDY OF DISPLACEMENT-LEVEL DEPENDENCY OF VERTICAL STIFFNESS OF PILE - COMPARISONS BETWEEN STATIC LOADING TEST AND MEASUREMENTS DURING TRAIN PASSING -

    Science.gov (United States)

    Nihei, Tatsuya; Nishioka, Hidetoshi; Kawamura, Chikara; Nishimura, Masahiro; Edamatsu, Masayuki; Koda, Masayuki

    In order to introduce the performance based design of pile foundation, vertical stiffness of pile is one of the important design factors. Although it had been es timated the vertical stiffness of pile had the displacement-level dependency, it had been not clarified. We compared the vertical stiffness of pile measured by two loading conditions at pile foundation of the railway viaduct. Firstly, we measured the vertical stiffness at static loading test under construction of the viaduct. Secondly, we measured the vertical stiffness at the time of train passing. So, we recognized that the extrapolation of the displacement level dependency in static loading test could evaluate the vertical stiffness of pile during train passing.

  15. Analytical evaluation of the signal and noise propagation in x-ray differential phase-contrast computed tomography

    International Nuclear Information System (INIS)

    Raupach, Rainer; Flohr, Thomas G

    2011-01-01

    We analyze the signal and noise propagation of differential phase-contrast computed tomography (PCT) compared with conventional attenuation-based computed tomography (CT) from a theoretical point of view. This work focuses on grating-based differential phase-contrast imaging. A mathematical framework is derived that is able to analytically predict the relative performance of both imaging techniques in the sense of the relative contrast-to-noise ratio for the contrast of any two materials. Two fundamentally different properties of PCT compared with CT are identified. First, the noise power spectra show qualitatively different characteristics implying a resolution-dependent performance ratio. The break-even point is derived analytically as a function of system parameters such as geometry and visibility. A superior performance of PCT compared with CT can only be achieved at a sufficiently high spatial resolution. Second, due to periodicity of phase information which is non-ambiguous only in a bounded interval statistical phase wrapping can occur. This effect causes a collapse of information propagation for low signals which limits the applicability of phase-contrast imaging at low dose.

  16. Moderate Contrast in the Evaluation of Paintings Is Liked More but Remembered Less than High Contrast

    Directory of Open Access Journals (Sweden)

    Katinka Dijkstra

    2017-09-01

    Full Text Available Many visual aspects of paintings, as well as exposure to art and cultural norms, contribute to the aesthetic evaluation of paintings. The current study looked at heightened visual contrast as an important factor in the appreciation of paintings. Participants evaluated abstract digitized paintings that were manipulated in contrast for an appreciation task and were later presented with these paintings in a memory task. The results indicated that for art appreciation, a moderate increase in contrast resulted in the highest appreciation for paintings whereas recognition memory was better for paintings with a higher increase in contrast. These results replicate earlier findings with regard to the role of contrast in aesthetic perception and extend these findings by demonstrating a surprising different effect of contrast manipulation for recognition memory. Confidence with which memory decisions were made was in line with art appreciation decisions not memory performance.

  17. Uroguanylin levels in intestine and plasma are regulated by nutritional status in a leptin-dependent manner.

    Science.gov (United States)

    Folgueira, C; Sanchez-Rebordelo, E; Barja-Fernandez, S; Leis, R; Tovar, S; Casanueva, F F; Dieguez, C; Nogueiras, R; Seoane, L M

    2016-03-01

    Uroguanylin (UGN) is a 16 amino acid peptide produced mainly by intestinal epithelial cells. Nutrients intake increases circulating levels of prouroguanylin that is processed and converted to UGN to activate the guanylyl cyclase 2C receptor (GUCY2C). Given that the UGN-GUCY2C system has been proposed as a novel gut-brain endocrine axis regulating energy balance, the aim of the present study was to investigate the regulation of UGN protein levels in duodenum and circulating levels in lean and obese mice under different nutritional conditions and its potential interaction with leptin. Swiss, C57BL/6 wild-type and ob/ob male adult mice under different nutritional conditions were used: fed ad libitum standard diet (control); 48 h fasting (fasted); 48 h fasting followed by 24 h of feeding (refed); and fed high-fat diet (45 %) during 10 weeks. In addition, peripheral leptin administration was performed. Intestinal uroguanylin expression was studied by Western blot analysis; plasma levels were measured by ELISA. Food deprivation significantly reduced plasma UGN levels, which were correlated with the lower protein levels of UGN in duodenum. These effects were reverted after refeeding and leptin challenge. Consistently, in ob/ob mice UGN expression was decreased, whereas leptin treatment up-regulated UGN levels in duodenum in these genetically modified mice compared to WT. Diet-induced obese mice displayed increased UGN levels in intestine and plasma in comparison with lean mice. Our findings suggest that UGN levels are correlated with energy balance status and that the regulation of UGN by nutritional status is leptin-dependent.

  18. Is hypoalbuminemia a prognostic risk factor for contrast-induced nephropathy in peritoneal dialysis patients?

    Directory of Open Access Journals (Sweden)

    Hassan K

    2014-10-01

    Full Text Available Kamal Hassan,1,2 Hassan Fadi3 1Faculty of Medicine in the Galilee, Bar-Ilan University, Safed, Israel; 2Peritoneal Dialysis Unit, Galilee Medical Center, Nahariya, Israel; 3Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel Objective: Residual renal function (RRF is an important predictor of outcome in peritoneal dialysis (PD patients. Hypoalbuminemia was found to be an independent risk factor for the development of acute kidney injury. We investigated the possibility of an association between serum albumin levels and the development of iodine contrast media-induced nephropathy (CIN in PD patients.Methods: A total of 103 PD patients who underwent invasive angiographies with exposure to iodine contrast media (ICM were reviewed retrospectively. All patients received 0.9% saline intravenously at a rate of 75 mL per hour for 12 hours prior, during, and 12 hours after exposure to ICM. Acetylcysteine was given orally at a dose of 600 mg twice daily, on the day before and on the day of exposure to ICM. The nonionic, low-osmolar contrast agent iopromide was used at a mean dose of 75.0±15.2 mL. The changes in RRF from baseline to 1 week and 4 weeks after exposure to ICM were recorded. Outcomes of patients with serum albumin levels <3.8 g/dL and those with serum albumin levels ≥3.8 g/dL were compared. A reduction >30% in RRF at 7 days after exposure to ICM was considered CIN.Results: CIN developed in 27.2% (28/103 of patients. Of the 103 patients, 59.2% (61 had serum albumin levels <3.8 g/dL. Of those, 37.7% (23/61 developed CIN, compared with 11.9% (5/42 of those with serum albumin levels ≥3.8 g/dL (P=0.004. After adjustment for all tested variables in a logistic regression with a stepwise selection model, serum albumin level at exposure to ICM was found to be the most powerful predictor of the development of CIN (odds ratio =4.5; confidence interval =1.5–13.0; P=0.006.Conclusion: PD patients with serum albumin levels <3.8 g

  19. Contrast myelography in the diagnosis of posterior hernias of lumbar intervertebral disks

    International Nuclear Information System (INIS)

    Maratkanova, T.V.; Morozova, T.D.

    1997-01-01

    Based on the analysis of the results of 297 contrast myelographies (MG) by means of water soluble agents made in patients with posterior hernias of lumbar intervertebral disks (PHLID), the authors define the potentialities of this technique in the diagnosis of PHLID. Additionally, two oblique X-ray films have been included into the exicting filming routine, which may detect all specific features of intervertebral disk damage at MG. The authors make additions into the wellknown myelographic symptomatology of PHLID, by outlining the abnormal anterior configuration of a contrast column at the level of a diseased disk in PHLID at the foraminal site. The findings suggest that contrast MG with nonionic water-soluble agents is a rather effective technique in the diagnosis of PHLID

  20. Combined fluorescence and phase contrast imaging at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Hornberger, B.; Feser, M.; Jacobsen, C.; Vogt, S.; Legnini, D.; Paterson, D.; Rehak, P.; DeGeronimo, G.; Palmer, B.M.; Experimental Facilities Division; State Univ. of New York at Stony Brook Univ.; BNL; Univ. of Vermont

    2006-01-01

    X-ray fluorescence microprobes excel at detecting and quantifying trace metals in biological and environmental science samples, but typically do not detect low Z elements such as carbon and nitrogen. Therefore, it is hard to put the trace metals into context with their natural environment. We are implementing phase contrast capabilities with a segmented detector into several microprobes at the Advanced Photon Source (APS) to address this problem. Qualitative differential phase contrast images from a modified soft x-ray detector already provide very useful information for general users. We are also implementing a quantitative method to recover the absolute phase shift by Fourier filtering detector images. New detectors are under development which are optimized for the signal levels present at the APS. In this paper, we concentrate on fundamental signal to noise considerations comparing absorption and differential phase contrast