WorldWideScience

Sample records for lesion candidate detection

  1. Detection of Fundus Lesions Using Classifier Selection

    Science.gov (United States)

    Nagayoshi, Hiroto; Hiramatsu, Yoshitaka; Sako, Hiroshi; Himaga, Mitsutoshi; Kato, Satoshi

    A system for detecting fundus lesions caused by diabetic retinopathy from fundus images is being developed. The system can screen the images in advance in order to reduce the inspection workload on doctors. One of the difficulties that must be addressed in completing this system is how to remove false positives (which tend to arise near blood vessels) without decreasing the detection rate of lesions in other areas. To overcome this difficulty, we developed classifier selection according to the position of a candidate lesion, and we introduced new features that can distinguish true lesions from false positives. A system incorporating classifier selection and these new features was tested in experiments using 55 fundus images with some lesions and 223 images without lesions. The results of the experiments confirm the effectiveness of the proposed system, namely, degrees of sensitivity and specificity of 98% and 81%, respectively.

  2. Red lesion detection using background estimation and lesions characteristics in diabetic retinal image

    Science.gov (United States)

    Zhang, Dongbo; Peng, Yinghui; Yi, Yao; Shang, Xingyu

    2013-10-01

    Detection of red lesions [hemorrhages (HRs) and microaneurysms (MAs)] is crucial for the diagnosis of early diabetic retinopathy. A method based on background estimation and adapted to specific characteristics of HRs and MAs is proposed. Candidate red lesions are located by background estimation and Mahalanobis distance measure and then some adaptive postprocessing techniques, which include vessel detection, nonvessel exclusion based on shape analysis, and noise points exclusion by double-ring filter (only used for MAs detection), are conducted to remove nonlesion pixels. The method is evaluated on our collected image dataset, and experimental results show that it is better than or approximate to other previous approaches. It is effective to reduce the false-positive and false-negative results that arise from incomplete and inaccurate vessel structure.

  3. Detection and classification of retinal lesions for grading of diabetic retinopathy.

    Science.gov (United States)

    Usman Akram, M; Khalid, Shehzad; Tariq, Anam; Khan, Shoab A; Azam, Farooque

    2014-02-01

    Diabetic Retinopathy (DR) is an eye abnormality in which the human retina is affected due to an increasing amount of insulin in blood. The early detection and diagnosis of DR is vital to save the vision of diabetes patients. The early signs of DR which appear on the surface of the retina are microaneurysms, haemorrhages, and exudates. In this paper, we propose a system consisting of a novel hybrid classifier for the detection of retinal lesions. The proposed system consists of preprocessing, extraction of candidate lesions, feature set formulation, and classification. In preprocessing, the system eliminates background pixels and extracts the blood vessels and optic disc from the digital retinal image. The candidate lesion detection phase extracts, using filter banks, all regions which may possibly have any type of lesion. A feature set based on different descriptors, such as shape, intensity, and statistics, is formulated for each possible candidate region: this further helps in classifying that region. This paper presents an extension of the m-Mediods based modeling approach, and combines it with a Gaussian Mixture Model in an ensemble to form a hybrid classifier to improve the accuracy of the classification. The proposed system is assessed using standard fundus image databases with the help of performance parameters, such as, sensitivity, specificity, accuracy, and the Receiver Operating Characteristics curves for statistical analysis. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Detection of white matter lesion regions in MRI using SLIC0 and convolutional neural network.

    Science.gov (United States)

    Diniz, Pedro Henrique Bandeira; Valente, Thales Levi Azevedo; Diniz, João Otávio Bandeira; Silva, Aristófanes Corrêa; Gattass, Marcelo; Ventura, Nina; Muniz, Bernardo Carvalho; Gasparetto, Emerson Leandro

    2018-04-19

    White matter lesions are non-static brain lesions that have a prevalence rate up to 98% in the elderly population. Because they may be associated with several brain diseases, it is important that they are detected as soon as possible. Magnetic Resonance Imaging (MRI) provides three-dimensional data with the possibility to detect and emphasize contrast differences in soft tissues, providing rich information about the human soft tissue anatomy. However, the amount of data provided for these images is far too much for manual analysis/interpretation, representing a difficult and time-consuming task for specialists. This work presents a computational methodology capable of detecting regions of white matter lesions of the brain in MRI of FLAIR modality. The techniques highlighted in this methodology are SLIC0 clustering for candidate segmentation and convolutional neural networks for candidate classification. The methodology proposed here consists of four steps: (1) images acquisition, (2) images preprocessing, (3) candidates segmentation and (4) candidates classification. The methodology was applied on 91 magnetic resonance images provided by DASA, and achieved an accuracy of 98.73%, specificity of 98.77% and sensitivity of 78.79% with 0.005 of false positives, without any false positives reduction technique, in detection of white matter lesion regions. It is demonstrated the feasibility of the analysis of brain MRI using SLIC0 and convolutional neural network techniques to achieve success in detection of white matter lesions regions. Copyright © 2018. Published by Elsevier B.V.

  5. Automated detection of Lupus white matter lesions in MRI

    Directory of Open Access Journals (Sweden)

    Eloy Roura Perez

    2016-08-01

    Full Text Available Brain magnetic resonance imaging provides detailed information which can be used to detect and segment white matter lesions (WML. In this work we propose an approach to automatically segment WML in Lupus patients by using T1w and fluid-attenuated inversion recovery (FLAIR images. Lupus WML appear as small focal abnormal tissue observed as hyperintensities in the FLAIR images. The quantification of these WML is a key factor for the stratification of lupus patients and therefore both lesion detection and segmentation play an important role. In our approach, the T1w image is first used to classify the three main tissues of the brain, white matter (WM, gray matter (GM and cerebrospinal fluid (CSF, while the FLAIR image is then used to detect focal WML as outliers of its GM intensity distribution. A set of post-processing steps based on lesion size, tissue neighborhood, and location are used to refine the lesion candidates. The proposal is evaluated on 20 patients, presenting qualitative and quantitative results in terms of precision and sensitivity of lesion detection (True Positive Rate (62% and Positive Prediction Value (80% respectively as well as segmentation accuracy (Dice Similarity Coefficient (72%. Obtained results illustrate the validity of the approach to automatically detect and segment lupus lesions. Besides, our approach is publicly available as a SPM8/12 toolbox extension with a simple parameter configuration.

  6. An ensemble deep learning based approach for red lesion detection in fundus images.

    Science.gov (United States)

    Orlando, José Ignacio; Prokofyeva, Elena; Del Fresno, Mariana; Blaschko, Matthew B

    2018-01-01

    Diabetic retinopathy (DR) is one of the leading causes of preventable blindness in the world. Its earliest sign are red lesions, a general term that groups both microaneurysms (MAs) and hemorrhages (HEs). In daily clinical practice, these lesions are manually detected by physicians using fundus photographs. However, this task is tedious and time consuming, and requires an intensive effort due to the small size of the lesions and their lack of contrast. Computer-assisted diagnosis of DR based on red lesion detection is being actively explored due to its improvement effects both in clinicians consistency and accuracy. Moreover, it provides comprehensive feedback that is easy to assess by the physicians. Several methods for detecting red lesions have been proposed in the literature, most of them based on characterizing lesion candidates using hand crafted features, and classifying them into true or false positive detections. Deep learning based approaches, by contrast, are scarce in this domain due to the high expense of annotating the lesions manually. In this paper we propose a novel method for red lesion detection based on combining both deep learned and domain knowledge. Features learned by a convolutional neural network (CNN) are augmented by incorporating hand crafted features. Such ensemble vector of descriptors is used afterwards to identify true lesion candidates using a Random Forest classifier. We empirically observed that combining both sources of information significantly improve results with respect to using each approach separately. Furthermore, our method reported the highest performance on a per-lesion basis on DIARETDB1 and e-ophtha, and for screening and need for referral on MESSIDOR compared to a second human expert. Results highlight the fact that integrating manually engineered approaches with deep learned features is relevant to improve results when the networks are trained from lesion-level annotated data. An open source implementation of our

  7. Hierarchical detection of red lesions in retinal images by multiscale correlation filtering

    Science.gov (United States)

    Zhang, Bob; Wu, Xiangqian; You, Jane; Li, Qin; Karray, Fakhri

    2009-02-01

    This paper presents an approach to the computer aided diagnosis (CAD) of diabetic retinopathy (DR) -- a common and severe complication of long-term diabetes which damages the retina and cause blindness. Since red lesions are regarded as the first signs of DR, there has been extensive research on effective detection and localization of these abnormalities in retinal images. In contrast to existing algorithms, a new approach based on Multiscale Correlation Filtering (MSCF) and dynamic thresholding is developed. This consists of two levels, Red Lesion Candidate Detection (coarse level) and True Red Lesion Detection (fine level). The approach was evaluated using data from Retinopathy On-line Challenge (ROC) competition website and we conclude our method to be effective and efficient.

  8. Cylindrical SUV distribution model for detecting skin lesions in body trunk FDG-PET/CT images

    International Nuclear Information System (INIS)

    Nemoto, Mitsutaka; Nomura, Yukihiro; Masutani, Yoshitaka; Yoshikawa, Takeharu; Hayashi, Naoto; Yoshioka, Naoki; Ohtomo, Kuni; Hanaoka, Shouhei

    2010-01-01

    We have been developing a computerized detection method for skin lesions in body trunk fluorodeoxyglucose-positron emission tomography (FDG-PET)/CT images. Spots on the skin with a high standard uptake value (SUV) are due not only to glucose metabolism in skin lesions but also to the physiological metabolism of organs near the skin. The distribution pattern of regional SUV on the skin is important information for the differential diagnosis of such high-SUV spots. In this study, we have developed a new skin lesion detection method based on a cylindrical SUV distribution model of the skin. The shape of the SUV distribution model is an approximation of the body trunk, and the SUV distribution model includes standard values for regional skin SUV. Classifier ensembles based on CT image features, SUV features, and subtraction features between the SUVs in FDG-PET images and the values in the SUV distribution model are used to extract and classify candidate regions for skin lesions. In a study of skin lesion detection using FDG-PET/CT images in 36 clinical cases, the true-positive rate was 61.7%, with 11.7 false-positive regions per case. The training results of the classifier ensemble for extracting and classifying candidate regions showed the effective features for detecting skin lesions in the study. (author)

  9. Computerized detection method for asymptomatic white matter lesions in brain screening MR images using a clustering technique

    International Nuclear Information System (INIS)

    Kunieda, Takuya; Uchiyama, Yoshikazu; Hara, Takeshi

    2008-01-01

    Asymptomatic white matter lesions are frequently identified by the screening system known as Brain Dock, which is intended for the detection of asymptomatic brain diseases. The detection of asymptomatic white matter lesions is important because their presence is associated with an increased risk of stroke. Therefore, we have developed a computerized method for the detection of asymptomatic white matter lesions in order to assist radiologists in image interpretation as a ''second opinion''. Our database consisted of T 1 - and T 2 -weighted images obtained from 73 patients. The locations of the white matter lesions were determined by an experienced neuroradiologist. In order to restrict the area to be searched for white matter lesions, we first segmented the cerebral region in T 1 -weighted images by applying thresholding and region-growing techniques. To identify the initial candidate lesions, k-means clustering with pixel values in T 1 - and T 2 -weighted images was applied to the segmented cerebral region. To eliminate false positives (FPs), we determined the features, such as location, size, and circularity, of each of the initial candidate lesions. Finally, a rule-based scheme and a quadratic discriminant analysis with these features were employed to distinguish between white matter lesions and FPs. The results showed that the sensitivity for the detection of white matter lesions was 93.2%, with 4.3 FPs per image, suggesting that our computerized method may be useful for the detection of asymptomatic white matter lesions in T 1 - and T 2 -weighted images. (author)

  10. Diagnostic imaging strategy for MDCT- or MRI-detected breast lesions: use of targeted sonography

    International Nuclear Information System (INIS)

    Nakano, Satoko; Ohtsuka, Masahiko; Mibu, Akemi; Karikomi, Masato; Sakata, Hitomi; Yamamoto, Masahiro

    2012-01-01

    Leading-edge technology such as magnetic resonance imaging (MRI) or computed tomography (CT) often reveals mammographically and ultrasonographically occult lesions. MRI is a well-documented, effective tool to evaluate these lesions; however, the detection rate of targeted sonography varies for MRI detected lesions, and its significance is not well established in diagnostic strategy of MRI detected lesions. We assessed the utility of targeted sonography for multidetector-row CT (MDCT)- or MRI-detected lesions in practice. We retrospectively reviewed 695 patients with newly diagnosed breast cancer who were candidates for breast conserving surgery and underwent MDCT or MRI in our hospital between January 2004 and March 2011. Targeted sonography was performed in all MDCT- or MRI-detected lesions followed by imaging-guided biopsy. Patient background, histopathology features and the sizes of the lesions were compared among benign, malignant and follow-up groups. Of the 695 patients, 61 lesions in 56 patients were detected by MDCT or MRI. The MDCT- or MRI-detected lesions were identified by targeted sonography in 58 out of 61 lesions (95.1%). Patients with pathological diagnoses were significantly older and more likely to be postmenopausal than the follow-up patients. Pathological diagnosis proved to be benign in 20 cases and malignant in 25. The remaining 16 lesions have been followed up. Lesion size and shape were not significantly different among the benign, malignant and follow-up groups. Approximately 95% of MDCT- or MRI-detected lesions were identified by targeted sonography, and nearly half of these lesions were pathologically proven malignancies in this study. Targeted sonography is a useful modality for MDCT- or MRI-detected breast lesions

  11. Bright Retinal Lesions Detection using Colour Fundus Images Containing Reflective Features

    Energy Technology Data Exchange (ETDEWEB)

    Giancardo, Luca [ORNL; Karnowski, Thomas Paul [ORNL; Chaum, Edward [ORNL; Meriaudeau, Fabrice [ORNL; Tobin Jr, Kenneth William [ORNL; Li, Yaquin [University of Tennessee, Knoxville (UTK)

    2009-01-01

    In the last years the research community has developed many techniques to detect and diagnose diabetic retinopathy with retinal fundus images. This is a necessary step for the implementation of a large scale screening effort in rural areas where ophthalmologists are not available. In the United States of America, the incidence of diabetes is worryingly increasing among the young population. Retina fundus images of patients younger than 20 years old present a high amount of reflection due to the Nerve Fibre Layer (NFL), the younger the patient the more these reflections are visible. To our knowledge we are not aware of algorithms able to explicitly deal with this type of reflection artefact. This paper presents a technique to detect bright lesions also in patients with a high degree of reflective NFL. First, the candidate bright lesions are detected using image equalization and relatively simple histogram analysis. Then, a classifier is trained using texture descriptor (Multi-scale Local Binary Patterns) and other features in order to remove the false positives in the lesion detection. Finally, the area of the lesions is used to diagnose diabetic retinopathy. Our database consists of 33 images from a telemedicine network currently developed. When determining moderate to high diabetic retinopathy using the bright lesions detected the algorithm achieves a sensitivity of 100% at a specificity of 100% using hold-one-out testing.

  12. Fully automatic detection of deep white matter T1 hypointense lesions in multiple sclerosis

    Science.gov (United States)

    Spies, Lothar; Tewes, Anja; Suppa, Per; Opfer, Roland; Buchert, Ralph; Winkler, Gerhard; Raji, Alaleh

    2013-12-01

    A novel method is presented for fully automatic detection of candidate white matter (WM) T1 hypointense lesions in three-dimensional high-resolution T1-weighted magnetic resonance (MR) images. By definition, T1 hypointense lesions have similar intensity as gray matter (GM) and thus appear darker than surrounding normal WM in T1-weighted images. The novel method uses a standard classification algorithm to partition T1-weighted images into GM, WM and cerebrospinal fluid (CSF). As a consequence, T1 hypointense lesions are assigned an increased GM probability by the standard classification algorithm. The GM component image of a patient is then tested voxel-by-voxel against GM component images of a normative database of healthy individuals. Clusters (≥0.1 ml) of significantly increased GM density within a predefined mask of deep WM are defined as lesions. The performance of the algorithm was assessed on voxel level by a simulation study. A maximum dice similarity coefficient of 60% was found for a typical T1 lesion pattern with contrasts ranging from WM to cortical GM, indicating substantial agreement between ground truth and automatic detection. Retrospective application to 10 patients with multiple sclerosis demonstrated that 93 out of 96 T1 hypointense lesions were detected. On average 3.6 false positive T1 hypointense lesions per patient were found. The novel method is promising to support the detection of hypointense lesions in T1-weighted images which warrants further evaluation in larger patient samples.

  13. Imaging inflammatory acne: lesion detection and tracking

    Science.gov (United States)

    Cula, Gabriela O.; Bargo, Paulo R.; Kollias, Nikiforos

    2010-02-01

    It is known that effectiveness of acne treatment increases when the lesions are detected earlier, before they could progress into mature wound-like lesions, which lead to scarring and discoloration. However, little is known about the evolution of acne from early signs until after the lesion heals. In this work we computationally characterize the evolution of inflammatory acne lesions, based on analyzing cross-polarized images that document acne-prone facial skin over time. Taking skin images over time, and being able to follow skin features in these images present serious challenges, due to change in the appearance of skin, difficulty in repositioning the subject, involuntary movement such as breathing. A computational technique for automatic detection of lesions by separating the background normal skin from the acne lesions, based on fitting Gaussian distributions to the intensity histograms, is presented. In order to track and quantify the evolution of lesions, in terms of the degree of progress or regress, we designed a study to capture facial skin images from an acne-prone young individual, followed over the course of 3 different time points. Based on the behavior of the lesions between two consecutive time points, the automatically detected lesions are classified in four categories: new lesions, resolved lesions (i.e. lesions that disappear completely), lesions that are progressing, and lesions that are regressing (i.e. lesions in the process of healing). The classification our methods achieve correlates well with visual inspection of a trained human grader.

  14. Optimization of PET system design for lesion detection

    International Nuclear Information System (INIS)

    Qi, Jinyi

    2000-01-01

    Traditionally, the figures of merit used in designing a PET scanner are spatial resolution, noise equivalent count rate, noise equivalent sensitivity, etc. These measures, however, do not directly reflect the lesion detectability using the PET scanner. Here we propose to optimize PET scanner design directly for lesion detection. The signal-to-noise ratio (SNR) of lesion detection can be easily computed using the theoretical expressions that we have previously derived. Because no time consuming Monte Carlo simulation is needed, the theoretical expressions allow evaluation of a large range of parameters. The PET system parameters can then be chosen to achieve the maximum SNR for lesion detection. The simulation study shown in this paper was focused a single ring PET scanner without depth of interaction measurement. Randoms and scatters were also ignored

  15. Automated detection of multiple sclerosis lesions in serial brain MRI

    International Nuclear Information System (INIS)

    Llado, Xavier; Ganiler, Onur; Oliver, Arnau; Marti, Robert; Freixenet, Jordi; Valls, Laia; Vilanova, Joan C.; Ramio-Torrenta, Lluis; Rovira, Alex

    2012-01-01

    Multiple sclerosis (MS) is a serious disease typically occurring in the brain whose diagnosis and efficacy of treatment monitoring are vital. Magnetic resonance imaging (MRI) is frequently used in serial brain imaging due to the rich and detailed information provided. Time-series analysis of images is widely used for MS diagnosis and patient follow-up. However, conventional manual methods are time-consuming, subjective, and error-prone. Thus, the development of automated techniques for the detection and quantification of MS lesions is a major challenge. This paper presents an up-to-date review of the approaches which deal with the time-series analysis of brain MRI for detecting active MS lesions and quantifying lesion load change. We provide a comprehensive reference source for researchers in which several approaches to change detection and quantification of MS lesions are investigated and classified. We also analyze the results provided by the approaches, discuss open problems, and point out possible future trends. Lesion detection approaches are required for the detection of static lesions and for diagnostic purposes, while either quantification of detected lesions or change detection algorithms are needed to follow up MS patients. However, there is not yet a single approach that can emerge as a standard for the clinical practice, automatically providing an accurate MS lesion evolution quantification. Future trends will focus on combining the lesion detection in single studies with the analysis of the change detection in serial MRI. (orig.)

  16. Automated detection of multiple sclerosis lesions in serial brain MRI

    Energy Technology Data Exchange (ETDEWEB)

    Llado, Xavier; Ganiler, Onur; Oliver, Arnau; Marti, Robert; Freixenet, Jordi [University of Girona, Computer Vision and Robotics Group, Girona (Spain); Valls, Laia [Dr. Josep Trueta University Hospital, Department of Radiology, Girona (Spain); Vilanova, Joan C. [Girona Magnetic Resonance Center, Girona (Spain); Ramio-Torrenta, Lluis [Dr. Josep Trueta University Hospital, Institut d' Investigacio Biomedica de Girona, Multiple Sclerosis and Neuroimmunology Unit, Girona (Spain); Rovira, Alex [Vall d' Hebron University Hospital, Magnetic Resonance Unit, Department of Radiology, Barcelona (Spain)

    2012-08-15

    Multiple sclerosis (MS) is a serious disease typically occurring in the brain whose diagnosis and efficacy of treatment monitoring are vital. Magnetic resonance imaging (MRI) is frequently used in serial brain imaging due to the rich and detailed information provided. Time-series analysis of images is widely used for MS diagnosis and patient follow-up. However, conventional manual methods are time-consuming, subjective, and error-prone. Thus, the development of automated techniques for the detection and quantification of MS lesions is a major challenge. This paper presents an up-to-date review of the approaches which deal with the time-series analysis of brain MRI for detecting active MS lesions and quantifying lesion load change. We provide a comprehensive reference source for researchers in which several approaches to change detection and quantification of MS lesions are investigated and classified. We also analyze the results provided by the approaches, discuss open problems, and point out possible future trends. Lesion detection approaches are required for the detection of static lesions and for diagnostic purposes, while either quantification of detected lesions or change detection algorithms are needed to follow up MS patients. However, there is not yet a single approach that can emerge as a standard for the clinical practice, automatically providing an accurate MS lesion evolution quantification. Future trends will focus on combining the lesion detection in single studies with the analysis of the change detection in serial MRI. (orig.)

  17. Incidentally Detected Enhancing Breast Lesions on Chest Computed Tomography

    International Nuclear Information System (INIS)

    Lin, Wen Chiung; Hsu, Hsian He; Yu, Jyh Cherng; Hsu, Giu Cheng; Yu, Cheng Ping; Chang, Tsun Hou; Huang, Guo Shu; Li, Chao Shiang

    2011-01-01

    To evaluate the nature and imaging appearance of incidental enhancing breast lesions detected on a routine contrast-enhanced chest CT. Twenty-three patients with incidental enhancing breast lesions on contrast-enhanced chest CT were retrospectively reviewed. The breast lesions were reviewed by unenhanced and enhanced CT, and evaluated by observing the shapes, margins, enhancement patterns and backgrounds of breast lesions. A histopathologic diagnosis or long-term follow-up served as reference standard. Sixteen (70%) patients had malignant breast lesions and seven (30%) had benign lesions. In 10 patients, the breast lesions were exclusively detected on contrast-enhanced CT. Using unenhanced CT, breast lesions with fi broglandular backgrounds were prone to be obscured (p < 0.001). Incidental primary breast cancer showed an non-significant trend of a higher percentage irregular margin (p = 0.056). All of the four incidental breast lesions with non-mass-like enhancement were proven to be malignant. Routine contrast-enhanced chest CT can reveal sufficient details to allow for the detection of unsuspected breast lesions, in which some cases may be proven as malignant. An irregular margin of incidental enhancing breast lesion can be considered a suggestive sign of malignancy

  18. A Robust and Fast System for CTC Computer-Aided Detection of Colorectal Lesions

    Directory of Open Access Journals (Sweden)

    Gareth Beddoe

    2010-01-01

    Full Text Available We present a complete, end-to-end computer-aided detection (CAD system for identifying lesions in the colon, imaged with computed tomography (CT. This system includes facilities for colon segmentation, candidate generation, feature analysis, and classification. The algorithms have been designed to offer robust performance to variation in image data and patient preparation. By utilizing efficient 2D and 3D processing, software optimizations, multi-threading, feature selection, and an optimized cascade classifier, the CAD system quickly determines a set of detection marks. The colon CAD system has been validated on the largest set of data to date, and demonstrates excellent performance, in terms of its high sensitivity, low false positive rate, and computational efficiency.

  19. Lesion detection and quantitation of positron emission mammography

    International Nuclear Information System (INIS)

    Qi, Jinyi; Huesman, Ronald H.

    2001-01-01

    A Positron Emission Mammography (PEM) scanner dedicated to breast imaging is being developed at our laboratory. We have developed a list mode likelihood reconstruction algorithm for this scanner. Here we theoretically study the lesion detection and quantitation. The lesion detectability is studied theoretically using computer observers. We found that for the zero-order quadratic prior, the region of interest observer can achieve the performance of the prewhitening observer with a properly selected smoothing parameter. We also study the lesion quantitation using the test statistic of the region of interest observer. The theoretical expressions for the bias, variance, and ensemble mean squared error of the quantitation are derived. Computer simulations show that the theoretical predictions are in good agreement with the Monte Carlo results for both lesion detection and quantitation

  20. Detection activity assessment and diagnosis of dental caries lesions

    DEFF Research Database (Denmark)

    Braga, Mariana M; Mendes, Fausto M; Ekstrand, Kim R

    2010-01-01

    This article reviews the current methods for detection and assessment of caries lesions focusing on applicability for daily clinical practice. The end point is to arrive at a diagnosis for each caries lesion. Visual inspection aided by a ball-ended probe is essential for caries lesions assessment...... and the method must be used for all patients. Use of indices, for example, the International Caries Detection and Assessment System (ICDAS), can improve the performance of this method. Using visual inspection, the clinician must decide about the presence, severity and activity of lesions. After this process...

  1. Automated detection of fundus photographic red lesions in diabetic retinopathy.

    Science.gov (United States)

    Larsen, Michael; Godt, Jannik; Larsen, Nicolai; Lund-Andersen, Henrik; Sjølie, Anne Katrin; Agardh, Elisabet; Kalm, Helle; Grunkin, Michael; Owens, David R

    2003-02-01

    To compare a fundus image-analysis algorithm for automated detection of hemorrhages and microaneurysms with visual detection of retinopathy in patients with diabetes. Four hundred fundus photographs (35-mm color transparencies) were obtained in 200 eyes of 100 patients with diabetes who were randomly selected from the Welsh Community Diabetic Retinopathy Study. A gold standard reference was defined by classifying each patient as having or not having diabetic retinopathy based on overall visual grading of the digitized transparencies. A single-lesion visual grading was made independently, comprising meticulous outlining of all single lesions in all photographs and used to develop the automated red lesion detection system. A comparison of visual and automated single-lesion detection in replicating the overall visual grading was then performed. Automated red lesion detection demonstrated a specificity of 71.4% and a resulting sensitivity of 96.7% in detecting diabetic retinopathy when applied at a tentative threshold setting for use in diabetic retinopathy screening. The accuracy of 79% could be raised to 85% by adjustment of a single user-supplied parameter determining the balance between the screening priorities, for which a considerable range of options was demonstrated by the receiver-operating characteristic (area under the curve 90.3%). The agreement of automated lesion detection with overall visual grading (0.659) was comparable to the mean agreement of six ophthalmologists (0.648). Detection of diabetic retinopathy by automated detection of single fundus lesions can be achieved with a performance comparable to that of experienced ophthalmologists. The results warrant further investigation of automated fundus image analysis as a tool for diabetic retinopathy screening.

  2. Discriminating dark matter candidates using direct detection

    International Nuclear Information System (INIS)

    Belanger, G.; Nezri, E.; Pukhov, A.

    2009-01-01

    We examine the predictions for both the spin-dependent and spin-independent direct detection rates in a variety of new particle physics models with dark matter candidates. We show that a determination of both spin-independent and spin-dependent amplitudes on protons and neutrons can in principle discriminate different candidates of dark matter up to a few ambiguities. We emphasize the importance of making measurements with different spin-dependent sensitive detector materials and the need for significant improvement of the detector sensitivities. Scenarios where exchange of new colored particles contributes significantly to the elastic scattering cross sections are often the most difficult to identify, the LHC should give an indication whether such scenarios are relevant for direct detection.

  3. Lesion Detection in CT Images Using Deep Learning Semantic Segmentation Technique

    Science.gov (United States)

    Kalinovsky, A.; Liauchuk, V.; Tarasau, A.

    2017-05-01

    In this paper, the problem of automatic detection of tuberculosis lesion on 3D lung CT images is considered as a benchmark for testing out algorithms based on a modern concept of Deep Learning. For training and testing of the algorithms a domestic dataset of 338 3D CT scans of tuberculosis patients with manually labelled lesions was used. The algorithms which are based on using Deep Convolutional Networks were implemented and applied in three different ways including slice-wise lesion detection in 2D images using semantic segmentation, slice-wise lesion detection in 2D images using sliding window technique as well as straightforward detection of lesions via semantic segmentation in whole 3D CT scans. The algorithms demonstrate superior performance compared to algorithms based on conventional image analysis methods.

  4. Optimal reconstructed section thickness for the detection of liver lesions with multidetector CT

    International Nuclear Information System (INIS)

    Soo, G.; Lau, K.K.; Yik, T.; Kutschera, P.

    2010-01-01

    Aim: To evaluate the impact of different reconstructed section thicknesses on liver lesion detection using multidetector computed tomography (CT). Methods: Fifty-three patients were examined using a 16-section CT machine with axial reconstructions provided at 2.5, 5, 7.5, and 10 mm section thicknesses. Images of different reconstructed section thicknesses from different patients were presented in random order to three independent, blinded radiologists for review at multiple sessions. All images were then reviewed by three radiologists in a common session. Consensus was reached following review of the previous interpretation results and results of follow-up imaging regarding the number of true liver lesions (n = 101) for comparison. Results: Mean detection rates were as follows: 93/101 lesions detected with the 2.5 mm section thickness, 98/101 lesions detected at the 5 mm section thickness, 78/101 lesions detected at the 7.5 mm section thickness, and 54/101 lesions detected at the 10 mm section thickness. Lesions missed at the 2.5 mm section thickness were due to masking by image noise. There was particular difficulty detecting subcapsular lesions and lesions adjacent to fissures or the gall bladder at the 7.5 mm and 10 mm section thicknesses. Conclusion: The optimal reconstructed section thickness for lesion detection in the liver was 5 mm.

  5. Candidate lesion-based criteria for defining a positive sacroiliac joint MRI in two cohorts of patients with axial spondyloarthritis

    DEFF Research Database (Denmark)

    Weber, Ulrich; Østergaard, Mikkel; Lambert, Robert G W

    2015-01-01

    OBJECTIVE: To determine candidate lesion-based criteria for a positive sacroiliac joint (SIJ) MRI based on bone marrow oedema (BMO) and/or erosion in non-radiographic axial spondyloarthritis (nr-axSpA); to compare the performance of lesion-based criteria with global evaluation by expert readers. ...... for classification of axial SpA, reflecting the contextual information provided by T1SE and STIR sequences....

  6. Evaluation of the Significance of Incidental Breast Lesions Detected by Chest CT

    International Nuclear Information System (INIS)

    Kim, Jae Hyun; Chang, Yun Woo; Hwang, Jung Hwa; Kim, Hyung Hwan; Lee, Eun Hye; Yang, Seung Boo

    2013-01-01

    To evaluate the significance of incidentally detected breast lesions on a chest CT scan. Thirty-six incidental breast lesions in 26 patients were detected on a chest CT scan and were correlated with breast sonography, retrospectively. Among them, twenty-four breast lesions in 20 patients that were correlated with chest CT and sonography were available to pathology or follow up sonography. The CT findings were compared with sonographic findings according to the pathologic results. Incidentally detected breast lesions on a chest CT scan were correlated with sonography in 86% (31/36). Among 24 lesions that were available to pathology or follow up sonography, seven (29.2%) lesions were malignant and 17 (70.8%) lesions were benign. CT revealed a significant difference between benign and malignant lesions in terms of shape and margin (p = 0.007; p = 0.008, respectively). The CT findings were well correlated with sonographic findings in shape and margin (p = 0.001, respectively). Incidentally detected breast lesions on chest CT can be correlated with sonography. An irregular shape or a non-circumscribed margin of breast lesions on a CT scan can be considered as a suggestive sign of malignancy.

  7. Small white matter lesion detection in cerebral small vessel disease

    Science.gov (United States)

    Ghafoorian, Mohsen; Karssemeijer, Nico; van Uden, Inge; de Leeuw, Frank E.; Heskes, Tom; Marchiori, Elena; Platel, Bram

    2015-03-01

    Cerebral small vessel disease (SVD) is a common finding on magnetic resonance images of elderly people. White matter lesions (WML) are important markers for not only the small vessel disease, but also neuro-degenerative diseases including multiple sclerosis, Alzheimer's disease and vascular dementia. Volumetric measurements such as the "total lesion load", have been studied and related to these diseases. With respect to SVD we conjecture that small lesions are important, as they have been observed to grow over time and they form the majority of lesions in number. To study these small lesions they need to be annotated, which is a complex and time-consuming task. Existing (semi) automatic methods have been aimed at volumetric measurements and large lesions, and are not suitable for the detection of small lesions. In this research we established a supervised voxel classification CAD system, optimized and trained to exclusively detect small WMLs. To achieve this, several preprocessing steps were taken, which included a robust standardization of subject intensities to reduce inter-subject intensity variability as much as possible. A number of features that were found to be well identifying small lesions were calculated including multimodal intensities, tissue probabilities, several features for accurate location description, a number of second order derivative features as well as multi-scale annular filter for blobness detection. Only small lesions were used to learn the target concept via Adaboost using random forests as its basic classifiers. Finally the results were evaluated using Free-response receiver operating characteristic.

  8. Multispectral detection of cutaneous lesions using spectroscopy and microscopy approaches

    Science.gov (United States)

    Borisova, E.; Genova-Hristova, Ts.; Troyanova, P.; Pavlova, E.; Terziev, I.; Semyachkina-Glushkovskaya, O.; Lomova, M.; Genina, E.; Stanciu, G.; Tranca, D.; Avramov, L.

    2018-02-01

    Autofluorescence, diffuse-reflectance and transmission spectral, and microscopic measurements were made on different cutaneous neoplastic lesions, namely basal cell carcinoma, squamous cell carcinoma, malignant melanoma, and dysplastic and benign lesions related. Spectroscopic measurements were made on ex vivo tissue samples, and confocal microscopy investigations were made on thin tissue slices. Fluorescence spectra obtained reveal statistically significant differences between the different benign, dysplastic and malignant lesions by the level of emission intensity, as well by spectral shape, which are fingerprints applicable for differentiation algorithms. In reflectance mode the most significant differences are related to the influence of skin pigments - melanin and hemoglobin. Transmission spectroscopy mode gave complementary optical properties information about the tissue samples investigated to that one of reflectance and absorption spectroscopy. Using autofluorescence detection of skin lesions we obtain very good diagnostic performance for distinguishing of nonmelanoma lesions. Using diffuse reflectance and transmission spectroscopy we obtain significant tool for pigmented pathologies differentiation, but it is a tool with moderate sensitivity for non-melanoma lesions detection. One could rapidly increase the diagnostic accuracy of the received combined "optical biopsy" method when several spectral detection techniques are applied in common algorithm for lesions' differentiation. Specific spectral features observed in each type of lesion investigated on micro and macro level would be presented and discussed. Correlation between the spectral data received and the microscopic features observed would be discussed in the report.

  9. Automated Breast Ultrasound Lesions Detection using Convolutional Neural Networks.

    Science.gov (United States)

    Yap, Moi Hoon; Pons, Gerard; Marti, Joan; Ganau, Sergi; Sentis, Melcior; Zwiggelaar, Reyer; Davison, Adrian K; Marti, Robert

    2017-08-07

    Breast lesion detection using ultrasound imaging is considered an important step of Computer-Aided Diagnosis systems. Over the past decade, researchers have demonstrated the possibilities to automate the initial lesion detection. However, the lack of a common dataset impedes research when comparing the performance of such algorithms. This paper proposes the use of deep learning approaches for breast ultrasound lesion detection and investigates three different methods: a Patch-based LeNet, a U-Net, and a transfer learning approach with a pretrained FCN-AlexNet. Their performance is compared against four state-of-the-art lesion detection algorithms (i.e. Radial Gradient Index, Multifractal Filtering, Rule-based Region Ranking and Deformable Part Models). In addition, this paper compares and contrasts two conventional ultrasound image datasets acquired from two different ultrasound systems. Dataset A comprises 306 (60 malignant and 246 benign) images and Dataset B comprises 163 (53 malignant and 110 benign) images. To overcome the lack of public datasets in this domain, Dataset B will be made available for research purposes. The results demonstrate an overall improvement by the deep learning approaches when assessed on both datasets in terms of True Positive Fraction, False Positives per image, and F-measure.

  10. Seven-Tesla Magnetization Transfer Imaging to Detect Multiple Sclerosis White Matter Lesions.

    Science.gov (United States)

    Chou, I-Jun; Lim, Su-Yin; Tanasescu, Radu; Al-Radaideh, Ali; Mougin, Olivier E; Tench, Christopher R; Whitehouse, William P; Gowland, Penny A; Constantinescu, Cris S

    2018-03-01

    Fluid-attenuated inversion recovery (FLAIR) imaging at 3 Tesla (T) field strength is the most sensitive modality for detecting white matter lesions in multiple sclerosis. While 7T FLAIR is effective in detecting cortical lesions, it has not been fully optimized for visualization of white matter lesions and thus has not been used for delineating lesions in quantitative magnetic resonance imaging (MRI) studies of the normal appearing white matter in multiple sclerosis. Therefore, we aimed to evaluate the sensitivity of 7T magnetization-transfer-weighted (MT w ) images in the detection of white matter lesions compared with 3T-FLAIR. Fifteen patients with clinically isolated syndrome, 6 with multiple sclerosis, and 10 healthy participants were scanned with 7T 3-dimensional (D) MT w and 3T-2D-FLAIR sequences on the same day. White matter lesions visible on either sequence were delineated. Of 662 lesions identified on 3T-2D-FLAIR images, 652 were detected on 7T-3D-MT w images (sensitivity, 98%; 95% confidence interval, 97% to 99%). The Spearman correlation coefficient between lesion loads estimated by the two sequences was .910. The intrarater and interrater reliability for 7T-3D-MT w images was good with an intraclass correlation coefficient (ICC) of 98.4% and 81.8%, which is similar to that for 3T-2D-FLAIR images (ICC 96.1% and 96.7%). Seven-Tesla MT w sequences detected most of the white matter lesions identified by FLAIR at 3T. This suggests that 7T-MT w imaging is a robust alternative for detecting demyelinating lesions in addition to 3T-FLAIR. Future studies need to compare the roles of optimized 7T-FLAIR and of 7T-MT w imaging. © 2017 The Authors. Journal of Neuroimaging published by Wiley Periodicals, Inc. on behalf of American Society of Neuroimaging.

  11. Targeted Ultrasound for MR-Detected Lesions in Breast Cancer Patients

    International Nuclear Information System (INIS)

    Shin, Jung Hee; Han, Boo Kyung; Choe, Yeon Hyeon; Ko, Kyung Ran; Choi, Nami

    2007-01-01

    To investigate the usefulness of targeted ultrasound (US) in the identification of additional suspicious lesions found by magnetic resonance (MR) imaging in breast cancer patients and the changes in treatment based on the identification of the lesions by the use of targeted US. One-hundred forty nine patients who underwent breast MR imaging for a preoperative evaluation of breast cancer between January 2002 and July 2004 were included in the study. We searched all cases for any additional lesions that were found initially by MR imaging and investigated the performance of targeted US in identifying the lesions. We also investigated their pathological outcomes and changes in treatment as a result of lesion identification. Of the 149 patients with breast cancer, additional suspicious lesions were detected with MR imaging in 62 patients (42%). Of the 69 additional lesions found in those 62 patients, 26 (38%) were confirmed as cancers by histology. Thirty-eight lesions in 31 patients were examined with targeted US and were histologically revealed as cancers in 18 (47%), high risk lesions in two (5%), benign lesions in 15 (39%), and unidentified lesions in three (8%). The cancer rate was statistically higher in lesions with a US correlate than in lesions without a US correlate (p = 0.028). Of 31 patients, the surgical plan was altered in 27 (87%). The use of targeted US justified a change in treatment for 22 patients (81%) and misled five patients (19%) into having an unnecessary surgical excision. Targeted US can play a useful role in the evaluation of additional suspicious lesions detected by MR imaging in breast cancer patients, but is limited in lesions without a US correlate

  12. Systematic evaluation of candidate blood markers for detecting ovarian cancer.

    Directory of Open Access Journals (Sweden)

    Chana Palmer

    2008-07-01

    Full Text Available Epithelial ovarian cancer is a significant cause of mortality both in the United States and worldwide, due largely to the high proportion of cases that present at a late stage, when survival is extremely poor. Early detection of epithelial ovarian cancer, and of the serous subtype in particular, is a promising strategy for saving lives. The low prevalence of ovarian cancer makes the development of an adequately sensitive and specific test based on blood markers very challenging. We evaluated the performance of a set of candidate blood markers and combinations of these markers in detecting serous ovarian cancer.We selected 14 candidate blood markers of serous ovarian cancer for which assays were available to measure their levels in serum or plasma, based on our analysis of global gene expression data and on literature searches. We evaluated the performance of these candidate markers individually and in combination by measuring them in overlapping sets of serum (or plasma samples from women with clinically detectable ovarian cancer and women without ovarian cancer. Based on sensitivity at high specificity, we determined that 4 of the 14 candidate markers--MUC16, WFDC2, MSLN and MMP7--warrant further evaluation in precious serum specimens collected months to years prior to clinical diagnosis to assess their utility in early detection. We also reported differences in the performance of these candidate blood markers across histological types of epithelial ovarian cancer.By systematically analyzing the performance of candidate blood markers of ovarian cancer in distinguishing women with clinically apparent ovarian cancer from women without ovarian cancer, we identified a set of serum markers with adequate performance to warrant testing for their ability to identify ovarian cancer months to years prior to clinical diagnosis. We argued for the importance of sensitivity at high specificity and of magnitude of difference in marker levels between cases and

  13. Intestinal lesions in pediatric Crohn disease: comparative detectability among pulse sequences at MR enterography

    International Nuclear Information System (INIS)

    Sohn, Beomseok; Kim, Myung-Joon; Lee, Mi-Jung; Koh, Hong; Han, Kyung Hwa

    2014-01-01

    Variable sequences can be used in MR enterography, and no consensus exists for the best protocol in children with Crohn disease. To compare the lesion detectability of various MR enterography sequences and to correlate the findings of these sequences with the Pediatric Crohn's Disease Activity Index (PCDAI) in children with Crohn disease. Children with clinically or pathologically confirmed Crohn disease underwent MR enterography, including a single-shot fast spin-echo (SSFSE) sequence, motility imaging (coronal 2-D balanced fast field echo), diffusion-weighted imaging (DWI), and dynamic contrast enhancement imaging (including arterial, portal and delayed phases). The lesion detectability of each sequence was graded 0-2 for each involved bowel segment. The lesion detectability and PCDAI result on different sequences were compared using the weighted least squares method and Student's t-test, respectively. Fifteen children (11 boys, 4 girls, mean age 13.7 ± 1.4 years) with a total of 41 lesions were included in this study. All lesions detected in more than two sequences were visible on the single-shot fast spin-echo (SSFSE) sequence. The relative lesion detection rate was 78.1% on motility imaging, 90.2% on DWI, and 92.7% on arterial, 95.1% on portal and 95.1% on delayed phase imaging. Compared to the SSFSE sequence, motility imaging (P < 0.001) and DWI (P = 0.039) demonstrated lower detectability. The mean PCDAI result in the detected lesions was statistically higher only on dynamic enhancement imaging (P < 0.001). All MR enterography sequences were found to have relatively high lesion detectability in children with Crohn disease, while motility imaging showed the lowest lesion detectability. Lesions detected on dynamic enhancement imaging showed a higher PCDAI result, which suggests that this sequence is specific for active inflammation. (orig.)

  14. Skin Lesion Analysis towards Melanoma Detection Using Deep Learning Network

    Science.gov (United States)

    2018-01-01

    Skin lesions are a severe disease globally. Early detection of melanoma in dermoscopy images significantly increases the survival rate. However, the accurate recognition of melanoma is extremely challenging due to the following reasons: low contrast between lesions and skin, visual similarity between melanoma and non-melanoma lesions, etc. Hence, reliable automatic detection of skin tumors is very useful to increase the accuracy and efficiency of pathologists. In this paper, we proposed two deep learning methods to address three main tasks emerging in the area of skin lesion image processing, i.e., lesion segmentation (task 1), lesion dermoscopic feature extraction (task 2) and lesion classification (task 3). A deep learning framework consisting of two fully convolutional residual networks (FCRN) is proposed to simultaneously produce the segmentation result and the coarse classification result. A lesion index calculation unit (LICU) is developed to refine the coarse classification results by calculating the distance heat-map. A straight-forward CNN is proposed for the dermoscopic feature extraction task. The proposed deep learning frameworks were evaluated on the ISIC 2017 dataset. Experimental results show the promising accuracies of our frameworks, i.e., 0.753 for task 1, 0.848 for task 2 and 0.912 for task 3 were achieved. PMID:29439500

  15. Skin Lesion Analysis towards Melanoma Detection Using Deep Learning Network

    Directory of Open Access Journals (Sweden)

    Yuexiang Li

    2018-02-01

    Full Text Available Skin lesions are a severe disease globally. Early detection of melanoma in dermoscopy images significantly increases the survival rate. However, the accurate recognition of melanoma is extremely challenging due to the following reasons: low contrast between lesions and skin, visual similarity between melanoma and non-melanoma lesions, etc. Hence, reliable automatic detection of skin tumors is very useful to increase the accuracy and efficiency of pathologists. In this paper, we proposed two deep learning methods to address three main tasks emerging in the area of skin lesion image processing, i.e., lesion segmentation (task 1, lesion dermoscopic feature extraction (task 2 and lesion classification (task 3. A deep learning framework consisting of two fully convolutional residual networks (FCRN is proposed to simultaneously produce the segmentation result and the coarse classification result. A lesion index calculation unit (LICU is developed to refine the coarse classification results by calculating the distance heat-map. A straight-forward CNN is proposed for the dermoscopic feature extraction task. The proposed deep learning frameworks were evaluated on the ISIC 2017 dataset. Experimental results show the promising accuracies of our frameworks, i.e., 0.753 for task 1, 0.848 for task 2 and 0.912 for task 3 were achieved.

  16. Skin Lesion Analysis towards Melanoma Detection Using Deep Learning Network.

    Science.gov (United States)

    Li, Yuexiang; Shen, Linlin

    2018-02-11

    Skin lesions are a severe disease globally. Early detection of melanoma in dermoscopy images significantly increases the survival rate. However, the accurate recognition of melanoma is extremely challenging due to the following reasons: low contrast between lesions and skin, visual similarity between melanoma and non-melanoma lesions, etc. Hence, reliable automatic detection of skin tumors is very useful to increase the accuracy and efficiency of pathologists. In this paper, we proposed two deep learning methods to address three main tasks emerging in the area of skin lesion image processing, i.e., lesion segmentation (task 1), lesion dermoscopic feature extraction (task 2) and lesion classification (task 3). A deep learning framework consisting of two fully convolutional residual networks (FCRN) is proposed to simultaneously produce the segmentation result and the coarse classification result. A lesion index calculation unit (LICU) is developed to refine the coarse classification results by calculating the distance heat-map. A straight-forward CNN is proposed for the dermoscopic feature extraction task. The proposed deep learning frameworks were evaluated on the ISIC 2017 dataset. Experimental results show the promising accuracies of our frameworks, i.e., 0.753 for task 1, 0.848 for task 2 and 0.912 for task 3 were achieved.

  17. Cystic lesion of pancreas - Intraductal papillary mucinous neoplasm

    Directory of Open Access Journals (Sweden)

    Rajiv Baijal

    2013-01-01

    Full Text Available Intraductal papillary mucinous neoplasm (IPMN of the pancreas is an intraductal mucin-producing epithelial neoplasm that arises from the main and/or branched pancreatic duct. It usually presents as cystic lesion of pancreas. There are well known differential diagnosis of cystic pancreatic lesion. Pancreatic cystic neoplasms are detected at an increasing frequency due to an increased use of abdominal imaging. The diagnosis and treatment of intraductal papillary mucinous tumors (IPMN of the pancreas has evolved over the past decade. IPMN represents a spectrum of disease, ranging from benign to malignant lesions, making the early detection and characterization of these lesions important. Definitive management is surgical resection for appropriate candidates, as benign lesions harbor malignant potential. IPMN has a prognosis, which is different from adenocarcinoma of the pancreas. We report a case of a 58-year-old male with intraductal papillary neoplasm involving main duct and side branches presenting to us with clinical symptoms of chronic pancreatitis with obstructive jaundice and cholangitis treated surgically.

  18. The detectability of hepatic metastases in candidates of radiofrequency ablation: comparison for helical CT scanning and late-phase pulse-inversion harmonic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kang Won; Yoon, Kwon Ha; Kim, Eun A; Park, Ki Han; Juhng, Seon Kwan; Won, Jong Jin [School of Medicine, Wonkwang Univ., Iksan (Korea, Republic of)

    2002-02-01

    To compare dual-phase helical CT and pulse inversion harmonic US using microbubble contrast agents in the detection of hepatic metastases prior to radiofrequency (RF) ablation. Twenty-one patients in whom hepatic metastases from colorectal cancer had been diagnosed by dual-phase CT scanning and who were considered to be candidates for RF ablation underwent pulse-inversion barmonic US examination. Images were obtained 5 minutes after the bolus injection of microbubble contrast agent SH U 508 A (4.0 g, 300 mg/mL). The number of metastatic tumors revealed by CT and US was determined, and the findings were statistically analysed. The influence of the results of US examination on treatment planning was also evaluated. In 21 patients, 48 metastaic lesions were detected by helical CT, and 56 lesions by US. These eight additional lesions revealed by US occurred in six patients (29%), and their diameter was 3-13 (mean, 7.2) mm. In three of these patients, RF ablation could not be performed ,while in the other three, the additional lesions were ablated. Pulse-inversion harmonic US imaging using microbubble contrast agents may depict small hepatic metastatic tumors that were not apparent at CT. US-therefore appears to be useful in the planning of treatment prior to the RF ablation of hepatic metastases.

  19. Automatic detection of breast lesions with MIBI-Tc99m scintimammography using a novelty filter

    International Nuclear Information System (INIS)

    Costa, M.; Moura, L.

    1996-01-01

    An automatic method for detecting breast lesion in scintimammography is described. It is reported that the proposed method not only detects lesions but also classifies them as benign or malignant. The detection method makes use of Kohonen's novelty filter and the classification method is obtained by the analysis of an identified lesion mean profile. The method was able to detect all lesions presented in the scintimammogram and to correctly classify 16 out of 17 malignant lesions and 15 out of 17 benign lesions. The sensitivity of the method was 94,12% and specificity was 88,24%

  20. Off-site evaluation of liver lesion detection by Gd-BOPTA-enhanced MR imaging

    International Nuclear Information System (INIS)

    Gehl, H.B.; Bourne, M.; Grazioli, L.; Moeller, A.; Lodemann, K.P.

    2001-01-01

    The aim of this study was to determine the efficacy of Gd-BOPTA-enhanced MRI in liver lesion detection in comparison with unenhanced MRI and dynamic CT. The image sets of 148 of 151 patients enrolled in a multicenter German phase-III trial were evaluated by two independent radiologists unaffiliated with the investigating centers. Patients underwent a routine MRI protocol comprising T2- and T1-weighted spin-echo and T1-weighted gradient-echo (GE) sequences pre and 1 h post 0.1 mmol/kg Gd-BOPTA (Bracco-Byk Gulden, Konstanz, Germany). Additionally, a serial T1-weighted GE scan was performed after administration of the first half of the dose. All patients underwent dynamic contrast-enhanced CT. The evaluation was performed with regard to the number and size of lesions detected per patient by each modality or sequence. Furthermore, all pre CM and pre + post CM image sets were analyzed for number of lesions per patient. Both readers detected significantly more lesions in the contrast-enhanced image set compared with the unenhanced image set (32 and 39 %, respectively; p < 0.0001). While contrast-enhanced CT detected a similar number of lesions to unenhanced MRI, it was clearly inferior to contrast-enhanced MRI (reader 1: p = 0.0117; reader 2: p = 0.0225). Of the T1-weighted scans performed, the dynamic and late T1-weighted GE exams contributed most to the increased lesion detection rate (reader 1: p = 0.0007; reader 2: p = 0.0037). The size of the smallest lesion detected by means of MRI was significantly larger in the pre-CM image sets than in the pre + post CM image sets (reader 1: p = 0.001; reader 2: p < 0.0001). Gd-BOPTA-enhanced MRI detected significantly smaller lesions than contrast-enhanced CT (reader 1: p = 0.0117; reader 2: p = 0.0925). Gd-BOPTA-enhanced MR imaging improves liver lesion detection significantly over unenhanced MRI and dynamic CT. (orig.)

  1. Off-site evaluation of liver lesion detection by Gd-BOPTA-enhanced MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gehl, H.B. [Inst. of Diagnostic Radiology, Medical Univ. of Luebeck (Germany); Bourne, M. [Dept. of Radiology, Univ. Hospital of Wales, Cardiff (United Kingdom); Grazioli, L. [Dept. of Radiology, Univ. of Brescia (Italy); Moeller, A. [MEDIDATA GmbH, Konstanz (Germany); Lodemann, K.P. [BRACCO-BYK GULDEN GmbH, Konstanz (Germany)

    2001-02-01

    The aim of this study was to determine the efficacy of Gd-BOPTA-enhanced MRI in liver lesion detection in comparison with unenhanced MRI and dynamic CT. The image sets of 148 of 151 patients enrolled in a multicenter German phase-III trial were evaluated by two independent radiologists unaffiliated with the investigating centers. Patients underwent a routine MRI protocol comprising T2- and T1-weighted spin-echo and T1-weighted gradient-echo (GE) sequences pre and 1 h post 0.1 mmol/kg Gd-BOPTA (Bracco-Byk Gulden, Konstanz, Germany). Additionally, a serial T1-weighted GE scan was performed after administration of the first half of the dose. All patients underwent dynamic contrast-enhanced CT. The evaluation was performed with regard to the number and size of lesions detected per patient by each modality or sequence. Furthermore, all pre CM and pre + post CM image sets were analyzed for number of lesions per patient. Both readers detected significantly more lesions in the contrast-enhanced image set compared with the unenhanced image set (32 and 39 %, respectively; p < 0.0001). While contrast-enhanced CT detected a similar number of lesions to unenhanced MRI, it was clearly inferior to contrast-enhanced MRI (reader 1: p = 0.0117; reader 2: p = 0.0225). Of the T1-weighted scans performed, the dynamic and late T1-weighted GE exams contributed most to the increased lesion detection rate (reader 1: p = 0.0007; reader 2: p = 0.0037). The size of the smallest lesion detected by means of MRI was significantly larger in the pre-CM image sets than in the pre + post CM image sets (reader 1: p = 0.001; reader 2: p < 0.0001). Gd-BOPTA-enhanced MRI detected significantly smaller lesions than contrast-enhanced CT (reader 1: p = 0.0117; reader 2: p = 0.0925). Gd-BOPTA-enhanced MR imaging improves liver lesion detection significantly over unenhanced MRI and dynamic CT. (orig.)

  2. Oriented regions grouping based candidate proposal for infrared pedestrian detection

    Science.gov (United States)

    Wang, Jiangtao; Zhang, Jingai; Li, Huaijiang

    2018-04-01

    Effectively and accurately locating the positions of pedestrian candidates in image is a key task for the infrared pedestrian detection system. In this work, a novel similarity measuring metric is designed. Based on the selective search scheme, the developed similarity measuring metric is utilized to yield the possible locations for pedestrian candidate. Besides this, corresponding diversification strategies are also provided according to the characteristics of the infrared thermal imaging system. Experimental results indicate that the presented scheme can achieve more efficient outputs than the traditional selective search methodology for the infrared pedestrian detection task.

  3. Computerized detection of mass lesions in digital mammograms

    International Nuclear Information System (INIS)

    Yin, F.F.; Giger, M.L.; Doi, K.; Metz, C.E.; Vyborny, C.J.; Schmidt, R.A.

    1989-01-01

    Early detection of breast cancer from the periodic screening of asymptomatic women could reduce breast cancer mortality by at least 40%. The authors are developing a computerized scheme for the detection of mass lesions in digital mammograms as an aid to radiologists in such high volume screening programs. Based on left-right architectural symmetry and gray-level histogram analysis, bilateral subtraction of left and right breast images is performed. False-positive detections included in bilateral-difference images are reduced with various images feature-extraction techniques. The database involves clinical film mammograms digitized by a TV camera and analyzed on a Micro-VAX workstation. Among five different bilateral subtraction techniques investigated, a nonlinear approach provided superior lesion enhancement. Feature-extraction techniques reduced substantially the remaining false-positives. Preliminary results, for 32 pairs of clinical mammograms, yielded a true-positive rate of approximately 95% with a false-positive rate of about 2 per image

  4. Generative adversarial networks for brain lesion detection

    Science.gov (United States)

    Alex, Varghese; Safwan, K. P. Mohammed; Chennamsetty, Sai Saketh; Krishnamurthi, Ganapathy

    2017-02-01

    Manual segmentation of brain lesions from Magnetic Resonance Images (MRI) is cumbersome and introduces errors due to inter-rater variability. This paper introduces a semi-supervised technique for detection of brain lesion from MRI using Generative Adversarial Networks (GANs). GANs comprises of a Generator network and a Discriminator network which are trained simultaneously with the objective of one bettering the other. The networks were trained using non lesion patches (n=13,000) from 4 different MR sequences. The network was trained on BraTS dataset and patches were extracted from regions excluding tumor region. The Generator network generates data by modeling the underlying probability distribution of the training data, (PData). The Discriminator learns the posterior probability P (Label Data) by classifying training data and generated data as "Real" or "Fake" respectively. The Generator upon learning the joint distribution, produces images/patches such that the performance of the Discriminator on them are random, i.e. P (Label Data = GeneratedData) = 0.5. During testing, the Discriminator assigns posterior probability values close to 0.5 for patches from non lesion regions, while patches centered on lesion arise from a different distribution (PLesion) and hence are assigned lower posterior probability value by the Discriminator. On the test set (n=14), the proposed technique achieves whole tumor dice score of 0.69, sensitivity of 91% and specificity of 59%. Additionally the generator network was capable of generating non lesion patches from various MR sequences.

  5. Fecal-tagging CT colonography with structure-analysis electronic cleansing for detection of colorectal flat lesions

    International Nuclear Information System (INIS)

    Xu, Yonghua; Cai, Wenli; Nappi, Janne; Yoshida, Hiro

    2012-01-01

    Purpose: To evaluate the feasibility and sensitivity of the 3D-reading of fecal-tagging CT colonography (CTC) with a novel structure-analysis electronic cleansing (SAEC) in detecting colorectal flat lesions in comparison with a cleansed 3D reading with Viatronix V3D Colon system (V3D) and primary uncleansed 2D reading (2D). Materials and methods: Forty CTC cases with flat lesions were retrospectively observed. The Subjects from a multicenter clinical trial underwent cathartic bowel preparation with orally administrated barium-based fecal-tagging. Sixty-nine flat lesions were confirmed using colonoscopy and histopathology as a reference standard. The results from SAEC reading were compared with those of prospective V3D and 2D readings. Results: Overall detection sensitivity with SAEC was 52% (36/69), which was statistically higher than that of 32% (22/69) and 29% (20/69) with V3D and 2D readings, respectively (p < 0.05). The sensitivities in detecting not-on-fold flat lesions were 63% (24/38), 45% (17/38), and 42% (16/38) with SAEC, V3D, and 2D readings, respectively; whereas those of on-fold flat lesions were 39% (12/31), 16% (5/31), and 13% (4/31), respectively. None of the eight flat lesions (2-9 mm) at cecum was detected by any of the three reading methods. Excluding the flat lesions at cecum, the sensitivity with SAEC for detecting flat lesion ≥4 mm increased to 84% (31/37). Conclusions: The fecal-tagging CTC with structure-analysis electronic cleansing could yield a high sensitivity for detecting flat lesions ≥4 mm. The not-on-fold flat lesions were detected with higher sensitivity than on-fold flat lesions.

  6. Theoretical evaluation of the detectability of random lesions in bayesian emission reconstruction

    International Nuclear Information System (INIS)

    Qi, Jinyi

    2003-01-01

    Detecting cancerous lesion is an important task in positron emission tomography (PET). Bayesian methods based on the maximum a posteriori principle (also called penalized maximum likelihood methods) have been developed to deal with the low signal to noise ratio in the emission data. Similar to the filter cut-off frequency in the filtered backprojection method, the prior parameters in Bayesian reconstruction control the resolution and noise trade-off and hence affect detectability of lesions in reconstructed images. Bayesian reconstructions are difficult to analyze because the resolution and noise properties are nonlinear and object-dependent. Most research has been based on Monte Carlo simulations, which are very time consuming. Building on the recent progress on the theoretical analysis of image properties of statistical reconstructions and the development of numerical observers, here we develop a theoretical approach for fast computation of lesion detectability in Bayesian reconstruction. The results can be used to choose the optimum hyperparameter for the maximum lesion detectability. New in this work is the use of theoretical expressions that explicitly model the statistical variation of the lesion and background without assuming that the object variation is (locally) stationary. The theoretical results are validated using Monte Carlo simulations. The comparisons show good agreement between the theoretical predications and the Monte Carlo results

  7. Automated lesion detection on MRI scans using combined unsupervised and supervised methods

    International Nuclear Information System (INIS)

    Guo, Dazhou; Fridriksson, Julius; Fillmore, Paul; Rorden, Christopher; Yu, Hongkai; Zheng, Kang; Wang, Song

    2015-01-01

    Accurate and precise detection of brain lesions on MR images (MRI) is paramount for accurately relating lesion location to impaired behavior. In this paper, we present a novel method to automatically detect brain lesions from a T1-weighted 3D MRI. The proposed method combines the advantages of both unsupervised and supervised methods. First, unsupervised methods perform a unified segmentation normalization to warp images from the native space into a standard space and to generate probability maps for different tissue types, e.g., gray matter, white matter and fluid. This allows us to construct an initial lesion probability map by comparing the normalized MRI to healthy control subjects. Then, we perform non-rigid and reversible atlas-based registration to refine the probability maps of gray matter, white matter, external CSF, ventricle, and lesions. These probability maps are combined with the normalized MRI to construct three types of features, with which we use supervised methods to train three support vector machine (SVM) classifiers for a combined classifier. Finally, the combined classifier is used to accomplish lesion detection. We tested this method using T1-weighted MRIs from 60 in-house stroke patients. Using leave-one-out cross validation, the proposed method can achieve an average Dice coefficient of 73.1 % when compared to lesion maps hand-delineated by trained neurologists. Furthermore, we tested the proposed method on the T1-weighted MRIs in the MICCAI BRATS 2012 dataset. The proposed method can achieve an average Dice coefficient of 66.5 % in comparison to the expert annotated tumor maps provided in MICCAI BRATS 2012 dataset. In addition, on these two test datasets, the proposed method shows competitive performance to three state-of-the-art methods, including Stamatakis et al., Seghier et al., and Sanjuan et al. In this paper, we introduced a novel automated procedure for lesion detection from T1-weighted MRIs by combining both an unsupervised and a

  8. Detecting circumscribed lesions with the Hough transform

    Energy Technology Data Exchange (ETDEWEB)

    Groshong, B.R; Kegelmeyer, W.P., Jr

    1996-01-11

    We have designed and implemented a circumscribed lesion detection algorithm, based on the Hough Transform, which will detect zero or more approximately circular structures in a mammogram over a range of radii from a few pixels to nearly the size of the breast. We address the geometrical behavior of peaks in Hough parameter space (x,y,r) for both the true radius of a circular structure in the image (r = r{sub o}), and for the parameter r as it passes through this radius. In addition, we evaluate peaks in Hough parameter space by re-analyzing the underlying mammogram in the vicinity of the circular disk indicated by the peak. Discs suggested by the resulting peaks are accumulated in a feature image, scaled by a measure of their quality. These results are then rectified with respect to image contrast extremes and average value. The result is a feature with a continuously scaled pixel level output which suggests the likelihood that a pixel is located inside a circular structure, irrespective of the radius of the structure and overall mammogram contrast. These features are evaluated fast qualitative and quantitative performance metrics which permit circumscribed lesion detection features to be initially evaluated without a full end-to-end classification experiment.

  9. Detection of flat colorectal polyps at screening CT colonography in comparison with conventional polypoid lesions

    Energy Technology Data Exchange (ETDEWEB)

    Sakamoto, Takashi; Urata, Joji [Diagnostic Imaging Center, Saiseikai Kumamoto Hospital, Kumamoto (Japan); Mitsuzaki, Katsuhiko; Matsuda, Katsuhiko; Kawakami, Megumi [Medical Examination Center, Saiseikai Kumamoto Hospital, Kumamoto (Japan); Utsunomiya, Daisuke; Yamamura, Sadahiro; Yamashita, Yasuyuki [Diagnostic Radiology, Faculty of Life Sciences, Kumamoto Univ., Kumamoto (Japan)], e-mail: utsunomi@kumamoto-u.ac.jp

    2012-09-15

    Background: Although the screening of small, flat polyps is clinically important, the role of CT colonography (CTC) screening in their detection has not been thoroughly investigated. Purpose: To evaluate the detection capability and usefulness of CTC in the screening of flat and polypoid lesions by comparing CTC with optic colonoscopy findings as the gold standard. Material and Methods: We evaluated the CTC detection capability for flat colorectal polyps with a flat surface and a height not exceeding 3 mm (n = 42) by comparing to conventional polypoid lesions (n = 418) according to the polyp diameter. Four types of reconstruction images including multiplanar reconstruction, volume rendering, virtual gross pathology, and virtual endoscopic images were used for visual analysis. We compared the abilities of the four reconstructions for polyp visualization. Results: Detection sensitivity for flat polyps was 31.3 %, 44.4 %, and 87.5 % for lesions measuring 2-3 mm, 4-5 mm, and {>=}6 mm, respectively; the corresponding sensitivity for polypoid lesions was 47.6 %, 79.0 %, and 91.7 %. The overall sensitivity for flat lesions (47.6%) was significantly lower than polypoid lesions (64.1%). Virtual endoscopic imaging showed best visualization among the four reconstructions. Colon cancers were detected in eight patients by optic colonoscopy, and CTC detected colon cancers in all eight patients. Conclusion: CTC using 64-row multidetector CT is useful for colon cancer screening to detect colorectal polyps while the detection of small, flat lesions is still challenging.

  10. Medical Imaging Lesion Detection Based on Unified Gravitational Fuzzy Clustering

    Directory of Open Access Journals (Sweden)

    Jean Marie Vianney Kinani

    2017-01-01

    Full Text Available We develop a swift, robust, and practical tool for detecting brain lesions with minimal user intervention to assist clinicians and researchers in the diagnosis process, radiosurgery planning, and assessment of the patient’s response to the therapy. We propose a unified gravitational fuzzy clustering-based segmentation algorithm, which integrates the Newtonian concept of gravity into fuzzy clustering. We first perform fuzzy rule-based image enhancement on our database which is comprised of T1/T2 weighted magnetic resonance (MR and fluid-attenuated inversion recovery (FLAIR images to facilitate a smoother segmentation. The scalar output obtained is fed into a gravitational fuzzy clustering algorithm, which separates healthy structures from the unhealthy. Finally, the lesion contour is automatically outlined through the initialization-free level set evolution method. An advantage of this lesion detection algorithm is its precision and its simultaneous use of features computed from the intensity properties of the MR scan in a cascading pattern, which makes the computation fast, robust, and self-contained. Furthermore, we validate our algorithm with large-scale experiments using clinical and synthetic brain lesion datasets. As a result, an 84%–93% overlap performance is obtained, with an emphasis on robustness with respect to different and heterogeneous types of lesion and a swift computation time.

  11. A comparison between fast and conventional spin-echo in the detection of multiple sclerosis lesions

    International Nuclear Information System (INIS)

    Thorpe, J.W.; Halpin, S.F.; MacManus, D.G.; Barker, G.J.; Kendall, B.E.; Miller, D.H.

    1994-01-01

    Long repetition time (TR) spin-echo (SE) with T 2 - or proton density weighting is the sequence of choice to detect the brain lesions of multiple sclerosis (MS). Fast spin-echo (FSE) permits the generation of T 2 -weighted images with similar contrast to SE but in a fraction of the time. We compared the sensitivity of FSE and SE in the detection of the brain lesions of MS. Six patients with clinically definite MS underwent brain imaging with both dual echo (long TR, long and short echo time (TE) SE and dual echo FSE. The SE and FSE images were first reviewed independently and then compared. A total of 404 lesions was detected on SE and 398 on FSE. Slightly more periventricular lesions were detected using SE than FSE (145 vs 127), whereas more posterior cranial fossa lesions were detected by FSE (77 vs 57). With both SE and FSE the short TE images revealed more lesions than the long echo. These results suggest that FSE could replace SE as the long TR sequence of choice in the investigation of MS. (orig.)

  12. Detection of Helicobacter pylori in Oral Lesions

    Directory of Open Access Journals (Sweden)

    Soussan Irani

    2013-12-01

    Full Text Available Background and aims. Helicobacter pylori is a microaerophilic gram-negative spiral organism. It is recognized as the etiologic factor for peptic ulcers, gastric adenocarcinoma and gastric lymphoma. Recently, it has been isolated from dental plaque and the dorsum of the tongue. This study was designed to assess the association between H. pylori and oral lesions such as ulcerative/inflammatory lesions, squamous cell carcinoma (SCC and primary lymphoma. Materials and methods. A total of 228 biopsies diagnosed as oral ulcerative/inflammatory lesions, oral squamous cell carcinoma (OSCC and oral primary lymphoma were selected from the archives of the Pathology Department. Thirty-two samples that were diagnosed as being without any pathological changes were selected as the control group. All the paraffin blocks were cut for hematoxylin and eosin staining to confirm the diagnoses and then the samples were prepared for immunohistochemistry staining. Data were collected and analyzed. Results. Chi-squared test showed significant differences between the frequency of H. pylori positivity in normal tissue and the lesions were examined (P=0.000. In addition, there was a statistically significant difference between the lesions examined (P=0.042. Chi-squared test showed significant differences between H. pylori positivity and different tissue types except inside the muscle layer as follows: in epithelium and in lamina propria (P=0.000, inside the blood vessels (P=0.003, inside the salivary gland duct (P=0.036, and muscle layer (P=0.122. Conclusion. There might be a relation between the presence of H. pylori and oral lesions. Therefore, early detection and eradication of H. pylori in high-risk patients are suggested.

  13. Stereotaxic cytology of nonpalpable lesions detected at mammography

    International Nuclear Information System (INIS)

    Ciatto, S.; Rosselli del Turco, M.; Bravetti, P.; Catarzi, S.

    1991-01-01

    The authors report on 791 consecutive cases undergoing stereotaxic cytology for non palpable lesions detected at mammography. Histologic diagnosis (malignant = 179, benign = 107) or mammographic folow-up after at least one year (benign = 275) was available in 561 cases. The overall inadequacy rate of stereotaxic cytology was 0.21, and dependent on lesion type (benign = 0.25, malignant = 0.13 p<0.001) and on sampling operator experience (range 0.17-0.31, p<0.001). Sensitivity (dubious+positive, after exclusion of inadequates) was 0.83 and dependent on histologic type (infiltrating = 0.87, intraductal = 0.68). Specificity (negative/benign, after exclusion of inadequates) was 0.96. Stereotaxic cytology helped in reducing the number of unnecessary beningn biopsies and the biopsy ratio was 0.6 benign to 1 malignant biopsy. In cases with moderate suspicion at mammography the radiologist felt reassured by negative cytology and advised mammographic control rather than surgical biopsy. Cytology was determinant in advising surgical biopsy in 9 cancer cases whereas the absence of cytologic positivity contributed to diagnostic delay in 2 cancer cases. Overall, stereotaxic cytology allowed a relevant reduction of unnecessary benign biopsies and should be routinely employed in the diagnostic work-up of nonpalpable lesions detected at mammography

  14. Comparison of AMI-25 enhanced MRI and helical dynamic CT in the detection of hepatic lesions

    International Nuclear Information System (INIS)

    Saitou, Kazuhiro; Matsuda, Hiromichi; Fukushima, Hiroaki; Kanzaki, Hiroshi; Hirose, Takashi; Karizaki, Dai; Abe, Kimihiko; Amino, Saburou

    1994-01-01

    We performed AMI-25 enhanced MRI and helical dynamic CT in 12 cases of hepatic lesions. Nine of these were hepatocellular carcinomas. Two cases were metastatic liver tumors (the primary lesion was gastric in one and the other was gallbladder cancer). One case was suspected to be adenomatous hyperplasia. Thirty-two lesions were detected in T2-weighted SE images before AMI-25 administration, while 46 lesions were detected in AMI-25 enhanced MRI images. In particular, AMI-25 enhanced MRI was superior to plain MRI in lesions less than 10 mm in size. A total of 48 lesions were detected in helical dynamic CT. Although AMI-25 enhanced MRI almost equaled helical dynamic CT in the detection of liver tumors, helical dynamic CT was slightly superior to AMI-25 enhanced MRI in the detection of subphrenic lesions. It was possible to know the hemodynamics in each hepatic lesion by helical dynamic CT. AMI-25 enhanced MRI was useful to know the inclusion of reticuloendothelial system, and that yielded different diagnoses in adenomatous hyperplasia and well differentiated hepatocellular carcinoma. Helical dynamic CT was useful for qualitative diagnosis. Both AMI-25 enhanced MRI and helical dynamic CT contributed to the detection of liver tumor and qualitative diagnosis. (author)

  15. Lesion detection in ultra-wide field retinal images for diabetic retinopathy diagnosis

    Science.gov (United States)

    Levenkova, Anastasia; Sowmya, Arcot; Kalloniatis, Michael; Ly, Angelica; Ho, Arthur

    2018-02-01

    Diabetic retinopathy (DR) leads to irreversible vision loss. Diagnosis and staging of DR is usually based on the presence, number, location and type of retinal lesions. Ultra-wide field (UWF) digital scanning laser technology provides an opportunity for computer-aided DR lesion detection. High-resolution UWF images (3078×2702 pixels) may allow detection of more clinically relevant retinopathy in comparison with conventional retinal images as UWF imaging covers a 200° retinal area, versus 45° by conventional cameras. Current approaches to DR diagnosis that analyze 7-field Early Treatment Diabetic Retinopathy Study (ETDRS) retinal images provide similar results to UWF imaging. However, in 40% of cases, more retinopathy was found outside the 7- field ETDRS fields by UWF and in 10% of cases, retinopathy was reclassified as more severe. The reason is that UWF images examine both the central retina and more peripheral regions. We propose an algorithm for automatic detection and classification of DR lesions such as cotton wool spots, exudates, microaneurysms and haemorrhages in UWF images. The algorithm uses convolutional neural network (CNN) as a feature extractor and classifies the feature vectors extracted from colour-composite UWF images using a support vector machine (SVM). The main contribution includes detection of four types of DR lesions in the peripheral retina for diagnostic purposes. The evaluation dataset contains 146 UWF images. The proposed method for detection of DR lesion subtypes in UWF images using two scenarios for transfer learning achieved AUC ≈ 80%. Data was split at the patient level to validate the proposed algorithm.

  16. Recurring DNA copy number gain at chromosome 9p13 plays a role in the activation of multiple candidate oncogenes in progressing oral premalignant lesions

    International Nuclear Information System (INIS)

    Towle, Rebecca; Tsui, Ivy F L; Zhu, Yuqi; MacLellan, Sara; Poh, Catherine F; Garnis, Cathie

    2014-01-01

    Genomic alteration at chromosome 9p has been previously reported as a frequent and critical event in oral premalignancy. While this alteration is typically reported as a loss driven by selection for CDKN2A deactivation (at 9p21.3), we detect a recurrent DNA copy number gain of ∼2.49 Mbp at chromosome 9p13 in oral premalignant lesions (OPLs) that later progressed to invasive lesions. This recurrent alteration event has been validated using fluorescence in situ hybridization in an independent set of OPLs. Analysis of publicly available gene expression datasets aided in identifying three oncogene candidates that may have driven selection for DNA copy number increases in this region (VCP, DCTN3, and STOML2). We performed in vitro silencing and activation experiments for each of these genes in oral cancer cell lines and found that each gene is independently capable of upregulating proliferation and anchorage-independent growth. We next analyzed the activity of each of these genes in biopsies of varying histological grades that were obtained from a diseased oral tissue field in a single patient, finding further molecular evidence of parallel activation of VCP, DCTN3, and STOML2 during progression from normal healthy tissue to invasive oral carcinoma. Our results support the conclusion that DNA gain at 9p13 is important to the earliest stages of oral tumorigenesis and that this alteration event likely contributes to the activation of multiple oncogene candidates capable of governing oral cancer phenotypes

  17. Automatic segmentation of lesions for the computer-assisted detection in fluorescence urology

    Science.gov (United States)

    Kage, Andreas; Legal, Wolfgang; Kelm, Peter; Simon, Jörg; Bergen, Tobias; Münzenmayer, Christian; Benz, Michaela

    2012-03-01

    Bladder cancer is one of the most common cancers in the western world. The diagnosis in Germany is based on the visual inspection of the bladder. This inspection performed with a cystoscope is a challenging task as some kinds of abnormal tissues do not differ much in their appearance from their surrounding healthy tissue. Fluorescence Cystoscopy has the potential to increase the detection rate. A liquid marker introduced into the bladder in advance of the inspection is concentrated in areas with high metabolism. Thus these areas appear as bright "glowing". Unfortunately, the fluorescence image contains besides the glowing of the suspicious lesions no more further visual information like for example the appearance of the blood vessels. A visual judgment of the lesion as well as a precise treatment has to be done using white light illumination. Thereby, the spatial information of the lesion provided by the fluorescence image has to be guessed by the clinical expert. This leads to a time consuming procedure due to many switches between the modalities and increases the risk of mistreatment. We introduce an automatic approach, which detects and segments any suspicious lesion in the fluorescence image automatically once the image was classified as a fluorescence image. The area of the contour of the detected lesion is transferred to the corresponding white light image and provide the clinical expert the spatial information of the lesion. The advantage of this approach is, that the clinical expert gets the spatial and the visual information of the lesion together in one image. This can save time and decrease the risk of an incomplete removal of a malign lesion.

  18. detecting multiple sclerosis lesions with a fully bioinspired visual attention model

    Science.gov (United States)

    Villalon-Reina, Julio; Gutierrez-Carvajal, Ricardo; Thompson, Paul M.; Romero-Castro, Eduardo

    2013-11-01

    The detection, segmentation and quantification of multiple sclerosis (MS) lesions on magnetic resonance images (MRI) has been a very active field for the last two decades because of the urge to correlate these measures with the effectiveness of pharmacological treatment. A myriad of methods has been developed and most of these are non specific for the type of lesions and segment the lesions in their acute and chronic phases together. On the other hand, radiologists are able to distinguish between several stages of the disease on different types of MRI images. The main motivation of the work presented here is to computationally emulate the visual perception of the radiologist by using modeling principles of the neuronal centers along the visual system. By using this approach we are able to detect the lesions in the majority of the images in our population sample. This type of approach also allows us to study and improve the analysis of brain networks by introducing a priori information.

  19. Differentiation of thyroid lesion detected by FDG PET/CT using SUV ratio

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bom Sahn; Kang, Won Jun; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul [Seoul National Univ. College of Medicine, Seoul (Korea, Republic of)

    2007-07-01

    We investigated the usefulness of SUV ratio to discriminate focal thyroid lesion incidentally detected on 18F-FDG PET/CT (FDG PET) in patients with malignant disease. A total of 2167 subjects with malignant tumor underwent PET/CT for staging. Forty-five of 2167 subjects (2.1%) showed hypermetabolic thyroid lesions on FDG PET. Of 45, 21 lesions were confirmed by pathology (n = 16) or follow up exam (n=5). Seventeen patients had focal FDG uptakes, while 4 patients had diffuse thyroid uptakes. Standardized uptake value (SUV) was measured by drawing region of interest (ROI) on bilateral thyroid lobes and liver. From 21 patients, 12 thyroid lesions were confirmed as malignant lesions and 9 lesions as benign lesions. All of bilateral thyroid FDG uptakes were determined as benign disease such as thyroiditis. From seventeen focal thyroid incidentaloma, FDG PET had 100 % (12/12) of sensitivity and 60 % (3/5) of specificity, retrospectively. Malignant nodules had a significantly higher lesion to liver ratio than those of benign nodules (2.10.9 vs. 1.20.6, p=0.029). With ROC curve, the best cut-off value of lesion to liver was 1.0 with sensitivity of 100% and specificity of 60 % (area under the curve=0.783). The SUV ratio of lesion to contralateral lobe do not have statistical significance to determine malignancy (3.72.1 vs. 2.61.7, p=0.079). This study showed that focal thyroidal FDG uptake detected by FDG PET could be differentiated with best performance by SUV ratio of lesion to liver.

  20. Importance of Defect Detectability in Positron Emission Tomography Imaging of Abdominal Lesions

    International Nuclear Information System (INIS)

    Yamashita, Shozo; Yokoyama, Kunihiko; Onoguchi, Masahisa; Yamamoto, Haruki; Nakaichi, Tetsu; Tsuji, Shiro; Nakajima, Kenichi

    2015-01-01

    This study was designed to assess defect detectability in positron emission tomography (PET) imaging of abdominal lesions. A National Electrical Manufactures Association International Electrotechnical Commission phantom was used. The simulated abdominal lesion was scanned for 10 min using dynamic list-mode acquisition method. Images, acquired with scan duration of 1-10 min, were reconstructed using VUE point HD and a 4.7 mm full-width at half-maximum (FWHM) Gaussian filter. Iteration-subset combinations of 2-16 and 2-32 were used. Visual and physical analyses were performed using the acquired images. To sequentially evaluate defect detectability in clinical settings, we examined two middle-aged male subjects. One had a liver cyst (approximately 10 mm in diameter) and the other suffered from pancreatic cancer with an inner defect region (approximately 9 mm in diameter). In the phantom study, at least 6 and 3 min acquisition durations were required to visualize 10 and 13 mm defect spheres, respectively. On the other hand, spheres with diameters ≥17 mm could be detected even if the acquisition duration was only 1 min. The visual scores were significantly correlated with background (BG) variability. In clinical settings, the liver cyst could be slightly visualized with an acquisition duration of 6 min, although image quality was suboptimal. For pancreatic cancer, the acquisition duration of 3 min was insufficient to clearly describe the defect region. The improvement of BG variability is the most important factor for enhancing lesion detection. Our clinical scan duration (3 min/bed) may not be suitable for the detection of small lesions or accurate tumor delineation since an acquisition duration of at least 6 min is required to visualize 10 mm lesions, regardless of reconstruction parameters. Improvements in defect detectability are important for radiation treatment planning and accurate PET-based diagnosis

  1. Spinal focal lesion detection in multiple myeloma using multimodal image features

    Science.gov (United States)

    Fränzle, Andrea; Hillengass, Jens; Bendl, Rolf

    2015-03-01

    Multiple myeloma is a tumor disease in the bone marrow that affects the skeleton systemically, i.e. multiple lesions can occur in different sites in the skeleton. To quantify overall tumor mass for determining degree of disease and for analysis of therapy response, volumetry of all lesions is needed. Since the large amount of lesions in one patient impedes manual segmentation of all lesions, quantification of overall tumor volume is not possible until now. Therefore development of automatic lesion detection and segmentation methods is necessary. Since focal tumors in multiple myeloma show different characteristics in different modalities (changes in bone structure in CT images, hypointensity in T1 weighted MR images and hyperintensity in T2 weighted MR images), multimodal image analysis is necessary for the detection of focal tumors. In this paper a pattern recognition approach is presented that identifies focal lesions in lumbar vertebrae based on features from T1 and T2 weighted MR images. Image voxels within bone are classified using random forests based on plain intensities and intensity value derived features (maximum, minimum, mean, median) in a 5 x 5 neighborhood around a voxel from both T1 and T2 weighted MR images. A test data sample of lesions in 8 lumbar vertebrae from 4 multiple myeloma patients can be classified at an accuracy of 95% (using a leave-one-patient-out test). The approach provides a reasonable delineation of the example lesions. This is an important step towards automatic tumor volume quantification in multiple myeloma.

  2. Impact of compressed breast thickness and dose on lesion detectability in digital mammography: FROC study with simulated lesions in real mammograms

    Energy Technology Data Exchange (ETDEWEB)

    Salvagnini, Elena, E-mail: elena.salvagnini@gmail.com [Department of Imaging and Pathology, Radiology, KUL, Herestraat 49, Leuven B-3000 (Belgium); SCK-CEN, Boeretang 200, Mol 2400 (Belgium); Bosmans, Hilde; Marshall, Nicholas W. [Department of Imaging and Pathology, Radiology, KUL, Herestraat 49, Leuven B-3000 (Belgium); Department of Radiology, Radiology, UZ Gasthuisberg, Herestraat 49, Leuven B-3000 (Belgium); Van Ongeval, Chantal; Van Steen, Andreas; Cockmartin, Lesley [Department of Radiology, Radiology, UZ Gasthuisberg, Herestraat 49, Leuven B-3000 (Belgium); Michielsen, Koen [Department of Imaging and Pathology, Nuclear Medicine and Molecular Imaging, KUL, Herestraat 49, Leuven B-3000 (Belgium); Struelens, Lara [SCK-CEN, Boeretang 200, Mol 2400 (Belgium)

    2016-09-15

    Purpose: The aim of this work was twofold: (1) to examine whether, with standard automatic exposure control (AEC) settings that maintain pixel values in the detector constant, lesion detectability in clinical images decreases as a function of breast thickness and (2) to verify whether a new AEC setup can increase lesion detectability at larger breast thicknesses. Methods: Screening patient images, acquired on two identical digital mammography systems, were collected over a period of 2 yr. Mammograms were acquired under standard AEC conditions (part 1) and subsequently with a new AEC setup (part 2), programmed to use the standard AEC settings for compressed breast thicknesses ≤49 mm, while a relative dose increase was applied above this thickness. The images were divided into four thickness groups: T1 ≤ 29 mm, T2 = 30–49 mm, T3 = 50–69 mm, and T4 ≥ 70 mm, with each thickness group containing 130 randomly selected craniocaudal lesion-free images. Two measures of density were obtained for every image: a BI-RADS score and a map of volumetric breast density created with a software application (VolparaDensity, Matakina, NZ). This information was used to select subsets of four images, containing one image from each thickness group, matched to a (global) BI-RADS score and containing a region with the same (local) VOLPARA volumetric density value. One selected lesion (a microcalcification cluster or a mass) was simulated into each of the four images. This process was repeated so that, for a given thickness group, half the images contained a single lesion and half were lesion-free. The lesion templates created and inserted in groups T3 and T4 for the first part of the study were then inserted into the images of thickness groups T3 and T4 acquired with higher dose settings. Finally, all images were visualized using the ViewDEX software and scored by four radiologists performing a free search study. A statistical jackknife-alternative free-response receiver operating

  3. A comparative study of the detectability of TMJ radiographic techniques for artificial mandibular condylar lesions

    International Nuclear Information System (INIS)

    Jeong, Hee Jeong; Jung, Yeon Hwa; Cho, Bong Hae

    1997-01-01

    The purpose of this study was to evaluate the detectability of various radiographic techniques for mandibular condylar lesions. Erosive lesion, osteophyte and flattening were formed on the artificial mandibular condyle, and panoramic, transcranial, transorbital radiography, lateral and frontal tomography were taken. The results were as follows; 1. The detectability for erosive lesions was superior in the order of frontal tomography (96%), lateral tomography (78%), transorbital (59%), transcranial (56%) and panoramic (48%) radiography. 2. The location of erosive lesion that showed the highest detectability was the medial third in panoramic, the lateral third in transcranial, the central portion of anteroposterior direction in transorbital, the central portion of mediolateral direction and the posterior third in lateral tomography. Frontal tomography disclosed all erosive lesions except one anterolateral lesion. 3. The detectability of osteophyte was 100% in lateral tomography, 78% in transcranial and 56% in panoramic radiography. 4. For flattening, lateral tomography showed the flattened condyle, but both panoramic and transcranial views showed only decreased bone density without the change of condylar shape.

  4. Improved Detection of Microsatellite Instability in Early Colorectal Lesions.

    Directory of Open Access Journals (Sweden)

    Jeffery W Bacher

    Full Text Available Microsatellite instability (MSI occurs in over 90% of Lynch syndrome cancers and is considered a hallmark of the disease. MSI is an early event in colon tumor development, but screening polyps for MSI remains controversial because of reduced sensitivity compared to more advanced neoplasms. To increase sensitivity, we investigated the use of a novel type of marker consisting of long mononucleotide repeat (LMR tracts. Adenomas from 160 patients, ranging in age from 29-55 years old, were screened for MSI using the new markers and compared with current marker panels and immunohistochemistry standards. Overall, 15 tumors were scored as MSI-High using the LMRs compared to 9 for the NCI panel and 8 for the MSI Analysis System (Promega. This difference represents at least a 1.7-fold increase in detection of MSI-High lesions over currently available markers. Moreover, the number of MSI-positive markers per sample and the size of allelic changes were significantly greater with the LMRs (p = 0.001, which increased confidence in MSI classification. The overall sensitivity and specificity of the LMR panel for detection of mismatch repair deficient lesions were 100% and 96%, respectively. In comparison, the sensitivity and specificity of the MSI Analysis System were 67% and 100%; and for the NCI panel, 75% and 97%. The difference in sensitivity between the LMR panel and the other panels was statistically significant (p<0.001. The increased sensitivity for detection of MSI-High phenotype in early colorectal lesions with the new LMR markers indicates that MSI screening for the early detection of Lynch syndrome might be feasible.

  5. Effects of surgical and chemical lesions on neurotransmitter candidates in the nucleus accumbens of the rat

    Energy Technology Data Exchange (ETDEWEB)

    Walaas, I; Fonnum, F

    1979-01-01

    The origin of fibers containing different neurotransmitter candidates in the nucleus accumbens of rat brain has been studied with surgical and chemical lesion techniques. Destruction of the medial forebrain bundle decreased the activity of aromatic amino acid decarboxylase by 80% in the nucleus. Cutting of the fornix or a hemitransection decreased the high affinity uptake of glutamate by 45% and the endogenous level of glutamate by 33%. The high affinity uptake of glutamate was concentrated in the synaptosomal fraction and the decrease after the lesion was most pronounced in this fraction. Restricted lesions indicated that fibers in the fimbria/fornix coming from the subiculum were responsible for this part of the glutamate uptake in the nucleus. Local injection of kainic acid into the nucleus was accompanied by a 75% decrease in choline acetyltransferase and a 35% decrease in acetylcholineserase activities, a 70% decrease in glutamate decarboxylase activity and a 60% decrease in the high affinity uptake of ..gamma..-aminobutyrate, a 45% decrease in high affinity glutamate uptake, and no change in aromatic amino acid decarboxylase activity. Performing a lesion of the fornix after kainic acid injection led to an 85% decrease in high affinity glutamate uptake, without further affecting the other neuronal markers. The results indicate that all aminergic fibers to the nucleus accumbens are ascending in the medial forebrain bundle, that the subiculum-accumbens fibers are glutamergic and the nucleus also contains intrinsic glutamergic or aspartergic cells. Cholinergic and ..gamma..-aminobutyrate-containing cells are wholly intrinsic to the nucleus.

  6. Random forest learning of ultrasonic statistical physics and object spaces for lesion detection in 2D sonomammography

    Science.gov (United States)

    Sheet, Debdoot; Karamalis, Athanasios; Kraft, Silvan; Noël, Peter B.; Vag, Tibor; Sadhu, Anup; Katouzian, Amin; Navab, Nassir; Chatterjee, Jyotirmoy; Ray, Ajoy K.

    2013-03-01

    Breast cancer is the most common form of cancer in women. Early diagnosis can significantly improve lifeexpectancy and allow different treatment options. Clinicians favor 2D ultrasonography for breast tissue abnormality screening due to high sensitivity and specificity compared to competing technologies. However, inter- and intra-observer variability in visual assessment and reporting of lesions often handicaps its performance. Existing Computer Assisted Diagnosis (CAD) systems though being able to detect solid lesions are often restricted in performance. These restrictions are inability to (1) detect lesion of multiple sizes and shapes, and (2) differentiate between hypo-echoic lesions from their posterior acoustic shadowing. In this work we present a completely automatic system for detection and segmentation of breast lesions in 2D ultrasound images. We employ random forests for learning of tissue specific primal to discriminate breast lesions from surrounding normal tissues. This enables it to detect lesions of multiple shapes and sizes, as well as discriminate between hypo-echoic lesion from associated posterior acoustic shadowing. The primal comprises of (i) multiscale estimated ultrasonic statistical physics and (ii) scale-space characteristics. The random forest learns lesion vs. background primal from a database of 2D ultrasound images with labeled lesions. For segmentation, the posterior probabilities of lesion pixels estimated by the learnt random forest are hard thresholded to provide a random walks segmentation stage with starting seeds. Our method achieves detection with 99.19% accuracy and segmentation with mean contour-to-contour error < 3 pixels on a set of 40 images with 49 lesions.

  7. Management of breast lesions detectable only on MRI

    International Nuclear Information System (INIS)

    Siegmann-Luz, K.C.; Bahrs, S.D.; Preibsch, H.; Hattermann, V.; Claussen, C.D.

    2014-01-01

    Breast MR imaging has become established as the most sensitive imaging method for diagnosing breast cancer. As a result of the increasing examination volume and improved image quality, the number of breast lesions detected only on MRI and requiring further clarification has risen in recent years. According to the S3-guideline 'Diagnosis, Therapy, and Follow-Up of Breast Cancer' as revised in July 2012, institutions performing breast MRI should provide the option of an MRI-guided intervention for clarification. This review describes the indications, methods and results of MRI-guided interventions for the clarification of breast lesions only visible on MRI. Recent guidelines and study results are also addressed and alternative methods and pitfalls are presented. (orig.)

  8. Comparisons of lesion detectability in ultrasound images acquired using time-shift compensation and spatial compounding.

    Science.gov (United States)

    Lacefield, James C; Pilkington, Wayne C; Waag, Robert C

    2004-12-01

    The effects of aberration, time-shift compensation, and spatial compounding on the discrimination of positive-contrast lesions in ultrasound b-scan images are investigated using a two-dimensional (2-D) array system and tissue-mimicking phantoms. Images were acquired within an 8.8 x 12-mm2 field of view centered on one of four statistically similar 4-mm diameter spherical lesions. Each lesion was imaged in four planes offset by successive 45 degree rotations about the central scan line. Images of the lesions were acquired using conventional geometric focusing through a water path, geometric focusing through a 35-mm thick distributed aberration phantom, and time-shift compensated transmit and receive focusing through the aberration phantom. The views of each lesion were averaged to form sets of water path, aberrated, and time-shift compensated 4:1 compound images and 16:1 compound images. The contrast ratio and detectability index of each image were computed to assess lesion differentiation. In the presence of aberration representative of breast or abdominal wall tissue, time-shift compensation provided statistically significant improvements of contrast ratio but did not consistently affect the detectability index, and spatial compounding significantly increased the detectability index but did not alter the contrast ratio. Time-shift compensation and spatial compounding thus provide complementary benefits to lesion detection.

  9. Scintigraphic detection of peptic lesions with the method of radiolabelled sucralfate

    International Nuclear Information System (INIS)

    Naumovski, J.; Kovkarova, E.; Simova, N.; Janevik-Ivanovska, E.; Georgievska- Kuzmanovska, S.

    2003-01-01

    Background. Sucralfate is an antiulcer agent that after peroral application strongly adheres to mucosal defects and in that way provides a protective barrier to further damage from acid and pepsin. If radiolabelled with a gamma isotope, it could be detected under a gamma camera pointing lesions to which it adhered. With the aim to confirm a suitable noninvasive method for investigation of caustic lesions of the upper gastrointestinal tract we evaluated in a preliminary study the validity of the radiolabelled Sucralfate scintigraphy in detection of peptic disease. Patients and methods. With that purpose, 35 patients after an endoscopic examination underwent scintigraphy with Tc-99m-DTPA sucralfate. Patients were divided in two groups: a group of 20 patients with endoscopic confirmed peptic disease and a control group of 15 persons who had not any disease of the upper gastrointestinal tract. Results. Using the test for clinical evaluation of a new method, the scan showed sensitivity of 75 %, specificity of 100 % and accuracy of 85.7 %. Conclusions. Scintigraphy with Tc-99m-DTPA Sucralfate promoting it as an additional method, complementary to routine investigations in detecting mucosal lesions. (author)

  10. Red Lesion Detection Using Dynamic Shape Features for Diabetic Retinopathy Screening.

    Science.gov (United States)

    Seoud, Lama; Hurtut, Thomas; Chelbi, Jihed; Cheriet, Farida; Langlois, J M Pierre

    2016-04-01

    The development of an automatic telemedicine system for computer-aided screening and grading of diabetic retinopathy depends on reliable detection of retinal lesions in fundus images. In this paper, a novel method for automatic detection of both microaneurysms and hemorrhages in color fundus images is described and validated. The main contribution is a new set of shape features, called Dynamic Shape Features, that do not require precise segmentation of the regions to be classified. These features represent the evolution of the shape during image flooding and allow to discriminate between lesions and vessel segments. The method is validated per-lesion and per-image using six databases, four of which are publicly available. It proves to be robust with respect to variability in image resolution, quality and acquisition system. On the Retinopathy Online Challenge's database, the method achieves a FROC score of 0.420 which ranks it fourth. On the Messidor database, when detecting images with diabetic retinopathy, the proposed method achieves an area under the ROC curve of 0.899, comparable to the score of human experts, and it outperforms state-of-the-art approaches.

  11. Role of multidetector computed tomography in evaluating incidentally detected breast lesions.

    Science.gov (United States)

    Moschetta, Marco; Scardapane, Arnaldo; Lorusso, Valentina; Rella, Leonarda; Telegrafo, Michele; Serio, Gabriella; Angelelli, Giuseppe; Ianora, Amato Antonio Stabile

    2015-01-01

    Computed tomography (CT) does not represent the primary method for the evaluation of breast lesions; however, it can detect breast abnormalities, even when performed for other reasons related to thoracic structures. The aim of this study is to evaluate the potential benefits of 320-row multidetector CT (MDCT) in evaluating and differentiating incidentally detected breast lesions by using vessel probe and 3D analysis software with net enhancement value. Sixty-two breast lesions in 46 patients who underwent 320-row chest CT examination were retrospectively evaluated. CT scans were assessed searching for the presence, location, number, morphological features, and density of breast nodules. Net enhancement was calculated by subtracting precontrast density from the density obtained by postcontrast values. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of CT were calculated for morphological features and net enhancement. Thirty of 62 lesions were found to be malignant at histological examination and 32 were found to be benign. When morphological features were considered, the sensitivity, specificity, accuracy, PPV, and NPV of CT were 87%, 100%, 88%, 100%, and 50%, respectively. Based on net enhancement, CT reached a sensitivity, specificity, accuracy, PPV, and NPV of 100%, 94%, 97%, 94%, and 100%, respectively. MDCT allows to recognize and characterize breast lesions based on morphological features. Net enhancement can be proposed as an additional accurate feature of CT.

  12. Automatic Detection of Lung and Liver Lesions in 3-D Positron Emission Tomography Images: A Pilot Study

    Science.gov (United States)

    Lartizien, Carole; Marache-Francisco, Simon; Prost, Rémy

    2012-02-01

    Positron emission tomography (PET) using fluorine-18 deoxyglucose (18F-FDG) has become an increasingly recommended tool in clinical whole-body oncology imaging for the detection, diagnosis, and follow-up of many cancers. One way to improve the diagnostic utility of PET oncology imaging is to assist physicians facing difficult cases of residual or low-contrast lesions. This study aimed at evaluating different schemes of computer-aided detection (CADe) systems for the guided detection and localization of small and low-contrast lesions in PET. These systems are based on two supervised classifiers, linear discriminant analysis (LDA) and the nonlinear support vector machine (SVM). The image feature sets that serve as input data consisted of the coefficients of an undecimated wavelet transform. An optimization study was conducted to select the best combination of parameters for both the SVM and the LDA. Different false-positive reduction (FPR) methods were evaluated to reduce the number of false-positive detections per image (FPI). This includes the removal of small detected clusters and the combination of the LDA and SVM detection maps. The different CAD schemes were trained and evaluated based on a simulated whole-body PET image database containing 250 abnormal cases with 1230 lesions and 250 normal cases with no lesion. The detection performance was measured on a separate series of 25 testing images with 131 lesions. The combination of the LDA and SVM score maps was shown to produce very encouraging detection performance for both the lung lesions, with 91% sensitivity and 18 FPIs, and the liver lesions, with 94% sensitivity and 10 FPIs. Comparison with human performance indicated that the different CAD schemes significantly outperformed human detection sensitivities, especially regarding the low-contrast lesions.

  13. Fast approach to evaluate MAP reconstruction for lesion detection and localization

    International Nuclear Information System (INIS)

    Qi, Jinyi; Huesman, Ronald H.

    2004-01-01

    Lesion detection is an important task in emission tomography. Localization ROC (LROC) studies are often used to analyze the lesion detection and localization performance. Most researchers rely on Monte Carlo reconstruction samples to obtain LROC curves, which can be very time-consuming for iterative algorithms. In this paper we develop a fast approach to obtain LROC curves that does not require Monte Carlo reconstructions. We use a channelized Hotelling observer model to search for lesions, and the results can be easily extended to other numerical observers. We theoretically analyzed the mean and covariance of the observer output. Assuming the observer outputs are multivariate Gaussian random variables, an LROC curve can be directly generated by integrating the conditional probability density functions. The high-dimensional integrals are calculated using a Monte Carlo method. The proposed approach is very fast because no iterative reconstruction is involved. Computer simulations show that the results of the proposed method match well with those obtained using the tradition LROC analysis

  14. Frequent Detection of Pancreatic Lesions in Asymptomatic High-Risk Individuals

    Science.gov (United States)

    Canto, Marcia Irene; Hruban, Ralph H.; Fishman, Elliot K.; Kamel, Ihab R.; Schulick, Richard; Zhang, Zhe; Topazian, Mark; Takahashi, Naoki; Fletcher, Joel; Petersen, Gloria; Klein, Alison P.; Axilbund, Jennifer; Griffin, Constance; Syngal, Sapna; Saltzman, John R.; Mortele, Koenraad J.; Lee, Jeffrey; Tamm, Eric; Vikram, Raghunandan; Bhosale, Priya; Margolis, Daniel; Farrell, James; Goggins, Michael

    2012-01-01

    BACKGROUND & AIMS The risk of pancreatic cancer is increased in patients with a strong family history of pancreatic cancer or a predisposing germline mutation. Screening can detect curable, non-invasive pancreatic neoplasms, but the optimal imaging approach is not known. We determined the baseline prevalence and characteristics of pancreatic abnormalities using 3 imaging tests to screen asymptomatic, high-risk individuals (HRI). METHODS We screened 225 asymptomatic adult HRI at 5 academic US medical centers once, using computed tomography (CT), magnetic resonance imaging (MRI), and endoscopic ultrasonography (EUS). We compared results in a blinded, independent fashion. RESULTS Ninety-two of 216 HRI (42%) were found to have at least 1 pancreatic mass (84 cystic, 3 solid) or a dilated pancreatic duct (n=5) by any of the imaging modalities. Fifty-one of the 84 HRI with a cyst (60.7%) had multiple lesions, typically small (mean 0.55 cm, range 2–39 mm), in multiple locations. The prevalence of pancreatic lesions increased with age; they were detected in 14% of subjects <50 years old, 34% of subjects 50–59 years old, and 53% of subjects 60–69 years old (P<.0001). CT, MRI, and EUS detected a pancreatic abnormality in 11%, 33.3%, and 42.6% of the HRI, respectively. Among these abnormalities, proven or suspected neoplasms were identified in 85 HRI (82 intraductal papillary mucinous neoplasms [IPMN] and 3 pancreatic endocrine tumors). Three of 5 HRI who underwent pancreatic resection had high-grade dysplasia in <3 cm IPMNs and in multiple intraepithelial neoplasias. CONCLUSIONS Screening of asymptomatic HRI frequently detects small pancreatic cysts, including curable, non-invasive high-grade neoplasms. EUS and MRI detect pancreatic lesions better than CT. PMID:22245846

  15. Texture alteration detection in bitemporal images of lesions with psoriasis

    DEFF Research Database (Denmark)

    Maletti, Gabriela Mariel; Ersbøll, Bjarne Kjær

    2003-01-01

    The objective of this work is to explore the feasibility of quantifying textural change between pairs of segmented patterns without registering them. The Multi-variate Alteration Detection (M.A.D.) Transform is applied to a texture model constructed with the data of segmented psoriasis lesions im...... images. The texture model is Haralick's co-occurrence matrix, which is computed and normalized for each single band with the equalized data of a given lesion. The contribution of each single color band to the textural change is analyzed....

  16. Improving mass candidate detection in mammograms via feature maxima propagation and local feature selection.

    Science.gov (United States)

    Melendez, Jaime; Sánchez, Clara I; van Ginneken, Bram; Karssemeijer, Nico

    2014-08-01

    Mass candidate detection is a crucial component of multistep computer-aided detection (CAD) systems. It is usually performed by combining several local features by means of a classifier. When these features are processed on a per-image-location basis (e.g., for each pixel), mismatching problems may arise while constructing feature vectors for classification, which is especially true when the behavior expected from the evaluated features is a peaked response due to the presence of a mass. In this study, two of these problems, consisting of maxima misalignment and differences of maxima spread, are identified and two solutions are proposed. The first proposed method, feature maxima propagation, reproduces feature maxima through their neighboring locations. The second method, local feature selection, combines different subsets of features for different feature vectors associated with image locations. Both methods are applied independently and together. The proposed methods are included in a mammogram-based CAD system intended for mass detection in screening. Experiments are carried out with a database of 382 digital cases. Sensitivity is assessed at two sets of operating points. The first one is the interval of 3.5-15 false positives per image (FPs/image), which is typical for mass candidate detection. The second one is 1 FP/image, which allows to estimate the quality of the mass candidate detector's output for use in subsequent steps of the CAD system. The best results are obtained when the proposed methods are applied together. In that case, the mean sensitivity in the interval of 3.5-15 FPs/image significantly increases from 0.926 to 0.958 (p < 0.0002). At the lower rate of 1 FP/image, the mean sensitivity improves from 0.628 to 0.734 (p < 0.0002). Given the improved detection performance, the authors believe that the strategies proposed in this paper can render mass candidate detection approaches based on image location classification more robust to feature

  17. Astrophysical dark matter: candidates from particle physics and detection possibilities

    International Nuclear Information System (INIS)

    Freese, K.

    1989-01-01

    In this talk, I will discuss the arguments that 50% to 90% of the matter in galaxies, including our own, is made of an unknown type of dark matter. I will review the reason why cosmologists believe Ω = 1 and illustrate the contrast with the limits on the amount of baryonic matter from element abundances in Big Bang Nucleosynthesis. Other arguments for nonbaryonic dark matter will also be discussed. Candidates for the dark matter from particle physics will be presented. I will focus on cold dark matter candidates known as WIMPs, weakly interacting massive (O(GeV)) particles. I will try to illustrate why these particles are interesting for astrophysics and outline ideas for cornering them. Detection possibilities for these particles include indirect detection, which takes advantage of the annihilation products of these particles in the galactic halo, the sun, or the earth. Direct detection via newly proposed cryogenic detectors must be sensitive to <∼ keV energy deposits. Annual modulation of the dark matter signal can be used as a signature for these halo particles. I hope to motivate the interest in these particles and discuss ideas for finding them

  18. Oral precancerous lesions: Problems of early detection and oral cancer prevention

    Science.gov (United States)

    Gileva, Olga S.; Libik, Tatiana V.; Danilov, Konstantin V.

    2016-08-01

    The study presents the results of the research in the structure, local and systemic risk factors, peculiarities of the clinical manifestation, and quality of primary diagnosis of precancerous oral mucosa lesions (OMLs). In the study a wide range of OMLs and high (25.4%) proportion of oral precancerous lesions (OPLs) in their structure was indicated. The high percentage of different diagnostic errors and the lack of oncological awareness of dental practitioners, as well as the sharp necessity of inclusion of precancer/cancer early detection techniques into their daily practice were noted. The effectiveness of chemilumenescence system of early OPLs and oral cancer detection was demonstrated, the prospects of infrared thermography as a diagnostic tool were also discussed.

  19. Pigmented skin lesion detection using random forest and wavelet-based texture

    Science.gov (United States)

    Hu, Ping; Yang, Tie-jun

    2016-10-01

    The incidence of cutaneous malignant melanoma, a disease of worldwide distribution and is the deadliest form of skin cancer, has been rapidly increasing over the last few decades. Because advanced cutaneous melanoma is still incurable, early detection is an important step toward a reduction in mortality. Dermoscopy photographs are commonly used in melanoma diagnosis and can capture detailed features of a lesion. A great variability exists in the visual appearance of pigmented skin lesions. Therefore, in order to minimize the diagnostic errors that result from the difficulty and subjectivity of visual interpretation, an automatic detection approach is required. The objectives of this paper were to propose a hybrid method using random forest and Gabor wavelet transformation to accurately differentiate which part belong to lesion area and the other is not in a dermoscopy photographs and analyze segmentation accuracy. A random forest classifier consisting of a set of decision trees was used for classification. Gabor wavelets transformation are the mathematical model of visual cortical cells of mammalian brain and an image can be decomposed into multiple scales and multiple orientations by using it. The Gabor function has been recognized as a very useful tool in texture analysis, due to its optimal localization properties in both spatial and frequency domain. Texture features based on Gabor wavelets transformation are found by the Gabor filtered image. Experiment results indicate the following: (1) the proposed algorithm based on random forest outperformed the-state-of-the-art in pigmented skin lesions detection (2) and the inclusion of Gabor wavelet transformation based texture features improved segmentation accuracy significantly.

  20. Lesion detection performance: comparative analysis of low-dose CT data of the chest on two hybrid imaging systems.

    Science.gov (United States)

    Jessop, Maryam; Thompson, John D; Coward, Joanne; Sanderud, Audun; Jorge, José; de Groot, Martijn; Lança, Luís; Hogg, Peter

    2015-03-01

    Incidental findings on low-dose CT images obtained during hybrid imaging are an increasing phenomenon as CT technology advances. Understanding the diagnostic value of incidental findings along with the technical limitations is important when reporting image results and recommending follow-up, which may result in an additional radiation dose from further diagnostic imaging and an increase in patient anxiety. This study assessed lesions incidentally detected on CT images acquired for attenuation correction on two SPECT/CT systems. An anthropomorphic chest phantom containing simulated lesions of varying size and density was imaged on an Infinia Hawkeye 4 and a Symbia T6 using the low-dose CT settings applied for attenuation correction acquisitions in myocardial perfusion imaging. Twenty-two interpreters assessed 46 images from each SPECT/CT system (15 normal images and 31 abnormal images; 41 lesions). Data were evaluated using a jackknife alternative free-response receiver-operating-characteristic analysis (JAFROC). JAFROC analysis showed a significant difference (P detection, with the figures of merit being 0.599 (95% confidence interval, 0.568, 0.631) and 0.810 (95% confidence interval, 0.781, 0.839) for the Infinia Hawkeye 4 and Symbia T6, respectively. Lesion detection on the Infinia Hawkeye 4 was generally limited to larger, higher-density lesions. The Symbia T6 allowed improved detection rates for midsized lesions and some lower-density lesions. However, interpreters struggled to detect small (5 mm) lesions on both image sets, irrespective of density. Lesion detection is more reliable on low-dose CT images from the Symbia T6 than from the Infinia Hawkeye 4. This phantom-based study gives an indication of potential lesion detection in the clinical context as shown by two commonly used SPECT/CT systems, which may assist the clinician in determining whether further diagnostic imaging is justified. © 2015 by the Society of Nuclear Medicine and Molecular Imaging

  1. Lesion detection and quantification performance of the Tachyon-I time-of-flight PET scanner: phantom and human studies

    Science.gov (United States)

    Zhang, Xuezhu; Peng, Qiyu; Zhou, Jian; Huber, Jennifer S.; Moses, William W.; Qi, Jinyi

    2018-03-01

    The first generation Tachyon PET (Tachyon-I) is a demonstration single-ring PET scanner that reaches a coincidence timing resolution of 314 ps using LSO scintillator crystals coupled to conventional photomultiplier tubes. The objective of this study was to quantify the improvement in both lesion detection and quantification performance resulting from the improved time-of-flight (TOF) capability of the Tachyon-I scanner. We developed a quantitative TOF image reconstruction method for the Tachyon-I and evaluated its TOF gain for lesion detection and quantification. Scans of either a standard NEMA torso phantom or healthy volunteers were used as the normal background data. Separately scanned point source and sphere data were superimposed onto the phantom or human data after accounting for the object attenuation. We used the bootstrap method to generate multiple independent noisy datasets with and without a lesion present. The signal-to-noise ratio (SNR) of a channelized hotelling observer (CHO) was calculated for each lesion size and location combination to evaluate the lesion detection performance. The bias versus standard deviation trade-off of each lesion uptake was also calculated to evaluate the quantification performance. The resulting CHO-SNR measurements showed improved performance in lesion detection with better timing resolution. The detection performance was also dependent on the lesion size and location, in addition to the background object size and shape. The results of bias versus noise trade-off showed that the noise (standard deviation) reduction ratio was about 1.1–1.3 over the TOF 500 ps and 1.5–1.9 over the non-TOF modes, similar to the SNR gains for lesion detection. In conclusion, this Tachyon-I PET study demonstrated the benefit of improved time-of-flight capability on lesion detection and ROI quantification for both phantom and human subjects.

  2. A soft kinetic data structure for lesion border detection.

    Science.gov (United States)

    Kockara, Sinan; Mete, Mutlu; Yip, Vincent; Lee, Brendan; Aydin, Kemal

    2010-06-15

    The medical imaging and image processing techniques, ranging from microscopic to macroscopic, has become one of the main components of diagnostic procedures to assist dermatologists in their medical decision-making processes. Computer-aided segmentation and border detection on dermoscopic images is one of the core components of diagnostic procedures and therapeutic interventions for skin cancer. Automated assessment tools for dermoscopic images have become an important research field mainly because of inter- and intra-observer variations in human interpretations. In this study, a novel approach-graph spanner-for automatic border detection in dermoscopic images is proposed. In this approach, a proximity graph representation of dermoscopic images in order to detect regions and borders in skin lesion is presented. Graph spanner approach is examined on a set of 100 dermoscopic images whose manually drawn borders by a dermatologist are used as the ground truth. Error rates, false positives and false negatives along with true positives and true negatives are quantified by digitally comparing results with manually determined borders from a dermatologist. The results show that the highest precision and recall rates obtained to determine lesion boundaries are 100%. However, accuracy of assessment averages out at 97.72% and borders errors' mean is 2.28% for whole dataset.

  3. Theoretical Analysis of Penalized Maximum-Likelihood Patlak Parametric Image Reconstruction in Dynamic PET for Lesion Detection.

    Science.gov (United States)

    Yang, Li; Wang, Guobao; Qi, Jinyi

    2016-04-01

    Detecting cancerous lesions is a major clinical application of emission tomography. In a previous work, we studied penalized maximum-likelihood (PML) image reconstruction for lesion detection in static PET. Here we extend our theoretical analysis of static PET reconstruction to dynamic PET. We study both the conventional indirect reconstruction and direct reconstruction for Patlak parametric image estimation. In indirect reconstruction, Patlak parametric images are generated by first reconstructing a sequence of dynamic PET images, and then performing Patlak analysis on the time activity curves (TACs) pixel-by-pixel. In direct reconstruction, Patlak parametric images are estimated directly from raw sinogram data by incorporating the Patlak model into the image reconstruction procedure. PML reconstruction is used in both the indirect and direct reconstruction methods. We use a channelized Hotelling observer (CHO) to assess lesion detectability in Patlak parametric images. Simplified expressions for evaluating the lesion detectability have been derived and applied to the selection of the regularization parameter value to maximize detection performance. The proposed method is validated using computer-based Monte Carlo simulations. Good agreements between the theoretical predictions and the Monte Carlo results are observed. Both theoretical predictions and Monte Carlo simulation results show the benefit of the indirect and direct methods under optimized regularization parameters in dynamic PET reconstruction for lesion detection, when compared with the conventional static PET reconstruction.

  4. Accuracy of the detection of infratentorial stroke lesions using perfusion CT: an experimenter-blinded study

    International Nuclear Information System (INIS)

    Lee, In Hyouk; Kim, Myung Soon; Kim, Young Ju; Lee, Myeong Sub; You, Joshua H.; Lee, Ji Yong; Whang, Kum

    2010-01-01

    Although perfusion CT (PCT) for the detection of supratentorial stroke is well established, there is a dearth of evidence of its effectiveness in the detection of infratentorial stroke. Hence, this study compared sensitivity, specificity, and accuracy of PCT maps between infratentorial and supratentorial stroke lesions. One hundred patients with acute stroke who had successfully undergone near whole-brain PCT with the toggling table technique and follow-up MRI were included. Wilcoxon Mann-Whitney test was performed at P 0.01 in all PCT maps) between supratentorial and infratentorial stroke. Also, there was no remarkable difference in both sensitivity and specificity of PCT maps. This was the first study to investigate the accuracy of PCT with the toggling table technique in detection of infratentorial stroke lesions. Clinically, PCT is highly reliable and accurate in detecting infratentorial stroke lesions. (orig.)

  5. Visual Inspection Displays Good Accuracy for Detecting Caries Lesions

    DEFF Research Database (Denmark)

    Twetman, Svante

    2015-01-01

    /QUESTION: To evaluate the overall accuracy of visual methods for detecting caries lesions. SOURCE OF FUNDING: Brazilian government (Process 2012/17888-1). TYPE OF STUDY/DESIGN: Systematic review with meta-analysis of data LEVEL OF EVIDENCE: Level 1: Good-quality, patient-oriented evidence STRENGTH OF RECOMMENDATION......ARTICLE TITLE AND BIBLIOGRAPHIC INFORMATION: Visual inspection for caries detection: a systematic review and meta-analysis. Gimenez T, Piovesan C, Braga MM, Raggio DP, Deery C, Ricketts DN, Ekstrand DR, Mendes FM. J Dent Res 2015;94(7):895-904. REVIEWER: Svante Twetman, DDS, PhD, Odont Dr PURPOSE...

  6. Neural network approach to radiologic lesion detection

    International Nuclear Information System (INIS)

    Newman, F.D.; Raff, U.; Stroud, D.

    1989-01-01

    An area of artificial intelligence that has gained recent attention is the neural network approach to pattern recognition. The authors explore the use of neural networks in radiologic lesion detection with what is known in the literature as the novelty filter. This filter uses a linear model; images of normal patterns become training vectors and are stored as columns of a matrix. An image of an abnormal pattern is introduced and the abnormality or novelty is extracted. A VAX 750 was used to encode the novelty filter, and two experiments have been examined

  7. Computer-aided detection system for masses in automated whole breast ultrasonography: development and evaluation of the effectiveness

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeoung Hyun [Dept. of Radiology, Ewha Womans University Mokdong Hospital, Ewha Womans University School of Medicine, Seoul (Korea, Republic of); Cha, Joo Hee; Kim, Nam Kug; Chang, Young Jun; Kim, Hak Hee [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Ko, Myung Su [Health Screening and Promotion Center, Asan Medical Center, Seoul (Korea, Republic of); Choi, Young Wook [Korea Electrotechnology Research Institute, Ansan (Korea, Republic of)

    2014-04-15

    The aim of this study was to evaluate the performance of a proposed computer-aided detection (CAD) system in automated breast ultrasonography (ABUS). Eighty-nine two-dimensional images (20 cysts, 42 benign lesions, and 27 malignant lesions) were obtained from 47 patients who underwent ABUS (ACUSON S2000). After boundary detection and removal, we detected mass candidates by using the proposed adjusted Otsu's threshold; the threshold was adaptive to the variations of pixel intensities in an image. Then, the detected candidates were segmented. Features of the segmented objects were extracted and used for training/testing in the classification. In our study, a support vector machine classifier was adopted. Eighteen features were used to determine whether the candidates were true lesions or not. A five-fold cross validation was repeated 20 times for the performance evaluation. The sensitivity and the false positive rate per image were calculated, and the classification accuracy was evaluated for each feature. In the classification step, the sensitivity of the proposed CAD system was 82.67% (SD, 0.02%). The false positive rate was 0.26 per image. In the detection/segmentation step, the sensitivities for benign and malignant mass detection were 90.47% (38/42) and 92.59% (25/27), respectively. In the five-fold cross-validation, the standard deviation of pixel intensities for the mass candidates was the most frequently selected feature, followed by the vertical position of the centroids. In the univariate analysis, each feature had 50% or higher accuracy. The proposed CAD system can be used for lesion detection in ABUS and may be useful in improving the screening efficiency.

  8. Radiologists' Performance for Detecting Lesions and the Interobserver Variability of Automated Whole Breast Ultrasound

    International Nuclear Information System (INIS)

    Kim, Sung Hun; Kang, Bong Joo; Choi, Byung Gil; Choi, Jae Jung; Lee, Ji Hye; Song, Byung Joo; Choe, Byung Joo; Park, Sarah; Kim, Hyunbin

    2013-01-01

    To compare the detection performance of the automated whole breast ultrasound (AWUS) with that of the hand-held breast ultrasound (HHUS) and to evaluate the interobserver variability in the interpretation of the AWUS. AWUS was performed in 38 breast cancer patients. A total of 66 lesions were included: 38 breast cancers, 12 additional malignancies and 16 benign lesions. Three breast radiologists independently reviewed the AWUS data and analyzed the breast lesions according to the BI-RADS classification. The detection rate of malignancies was 98.0% for HHUS and 90.0%, 88.0% and 96.0% for the three readers of the AWUS. The sensitivity and the specificity were 98.0% and 62.5% in HHUS, 90.0% and 87.5% for reader 1, 88.0% and 81.3% for reader 2, and 96.0% and 93.8% for reader 3, in AWUS. There was no significant difference in the radiologists' detection performance, sensitivity and specificity (p > 0.05) between the two modalities. The interobserver agreement was fair to good for the ultrasonographic features, categorization, size, and the location of breast masses. AWUS is thought to be useful for detecting breast lesions. In comparison with HHUS, AWUS shows no significant difference in the detection rate, sensitivity and the specificity, with high degrees of interobserver agreement

  9. Radiologists' Performance for Detecting Lesions and the Interobserver Variability of Automated Whole Breast Ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Hun; Kang, Bong Joo; Choi, Byung Gil; Choi, Jae Jung; Lee, Ji Hye [Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul 137-701 (Korea, Republic of); Song, Byung Joo; Choe, Byung Joo [Department of General Surgery, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul 137-701 (Korea, Republic of); Park, Sarah [Department of Internal Medicine, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul 137-701 (Korea, Republic of); Kim, Hyunbin [CMC Clinical Research Coordinating Center, College of Medicine, The Catholic University of Korea, Seoul 137-701 (Korea, Republic of)

    2013-07-01

    To compare the detection performance of the automated whole breast ultrasound (AWUS) with that of the hand-held breast ultrasound (HHUS) and to evaluate the interobserver variability in the interpretation of the AWUS. AWUS was performed in 38 breast cancer patients. A total of 66 lesions were included: 38 breast cancers, 12 additional malignancies and 16 benign lesions. Three breast radiologists independently reviewed the AWUS data and analyzed the breast lesions according to the BI-RADS classification. The detection rate of malignancies was 98.0% for HHUS and 90.0%, 88.0% and 96.0% for the three readers of the AWUS. The sensitivity and the specificity were 98.0% and 62.5% in HHUS, 90.0% and 87.5% for reader 1, 88.0% and 81.3% for reader 2, and 96.0% and 93.8% for reader 3, in AWUS. There was no significant difference in the radiologists' detection performance, sensitivity and specificity (p > 0.05) between the two modalities. The interobserver agreement was fair to good for the ultrasonographic features, categorization, size, and the location of breast masses. AWUS is thought to be useful for detecting breast lesions. In comparison with HHUS, AWUS shows no significant difference in the detection rate, sensitivity and the specificity, with high degrees of interobserver agreement.

  10. A subtraction pipeline for automatic detection of new appearing multiple sclerosis lesions in longitudinal studies

    Energy Technology Data Exchange (ETDEWEB)

    Ganiler, Onur; Oliver, Arnau; Diez, Yago; Freixenet, Jordi; Llado, Xavier [University of Girona, VICOROB Computer Vision and Robotics Group, Girona (Spain); Vilanova, Joan C. [Girona Magnetic Resonance Center, Girona (Spain); Beltran, Brigitte [Dr. Josep Trueta University Hospital, Institut d' Investigacio Biomedica de Girona, Girona (Spain); Ramio-Torrenta, Lluis [Dr. Josep Trueta University Hospital, Institut d' Investigacio Biomedica de Girona, Multiple Sclerosis and Neuroimmunology Unit, Girona (Spain); Rovira, Alex [Vall d' Hebron University Hospital, Magnetic Resonance Unit, Department of Radiology, Barcelona (Spain)

    2014-05-15

    Time-series analysis of magnetic resonance images (MRI) is of great value for multiple sclerosis (MS) diagnosis and follow-up. In this paper, we present an unsupervised subtraction approach which incorporates multisequence information to deal with the detection of new MS lesions in longitudinal studies. The proposed pipeline for detecting new lesions consists of the following steps: skull stripping, bias field correction, histogram matching, registration, white matter masking, image subtraction, automated thresholding, and postprocessing. We also combine the results of PD-w and T2-w images to reduce false positive detections. Experimental tests are performed in 20 MS patients with two temporal studies separated 12 (12M) or 48 (48M) months in time. The pipeline achieves very good performance obtaining an overall sensitivity of 0.83 and 0.77 with a false discovery rate (FDR) of 0.14 and 0.18 for the 12M and 48M datasets, respectively. The most difficult situation for the pipeline is the detection of very small lesions where the obtained sensitivity is lower and the FDR higher. Our fully automated approach is robust and accurate, allowing detection of new appearing MS lesions. We believe that the pipeline can be applied to large collections of images and also be easily adapted to monitor other brain pathologies. (orig.)

  11. Ultrasonographic detection of focal liver lesions: increased sensitivity and specificity with microbubble contrast agents

    International Nuclear Information System (INIS)

    Hohmann, J.; Albrecht, T.; Hoffmann, C.W.; Wolf, K.-J.

    2003-01-01

    Ultrasonography (US) is the first choice for screening patients with suspected liver lesions. However, due to a lack of contrast agents, US used to be less sensitive and specific compared with computed tomography (CT) and magnet resonance imaging (MRI). The advent of microbubble contrast agents increased both sensitivity and specificity dramatically. Rapid developments of the contrast agents as well as of special imaging techniques were made in recent years. Today numerous different US imaging methods exist which based either on Doppler or on harmonic imaging. They are using the particular behaviour of microbubbles in a sound field which varies depending on the energy of insonation (low/high mechanical index, MI) as well as on the properties of the agent themselves. Apart from just blood pool enhancement some agents have a hepatosplenic specific late phase. US imaging during this late phase using relatively high MI in phase inversion mode (harmonic imaging) or stimulated acoustic emission (SAE; Doppler method) markedly improves the detection of focal liver lesions and is also very helpful for lesion characterisation. With regards to detection, contrast enhanced US performs similarly to CT as shown by recent studies. Early results of studies using low MI imaging and the newer perfluor agents are also showing promising results for lesion detection. Low MI imaging with these agents has the advantage of real time imaging and is particularly helpful for characterisation of focal lesions based on their dynamic contrast behaviour. Apart from the techniques which based on the morphology of liver lesions there were some attempts for the detection of occult metastases or micrometastases by means of liver blood flow changes. Also in this field the use of US contrast agents appears to have advantages over formerly used non contrast-enhanced methods although no conclusive results are available yet

  12. Detection of intaoral lesions using a fluorescence camera

    Science.gov (United States)

    Thoms, Michael

    2006-02-01

    Optical methods for the detection of carious lesions, calculus and plaque have the advantage of being minimally invasive. The use of endogeneous fluorescence markers like porphyrins could simplify the application of fluorescence techniques in the dental practice. It is known that porphyrins are produced by some of the bacterial species that are present in the oral cavity. Since porphyrins have an excitation band at about 400nm they have the potential to be used as fluorescent markers of locations in the oral cavity where the production of bacteria is out of the limits of healthy regions. Further, modern and efficient GaN-based semiconductor diodes emit light in this spectral range and thus make the implementation of fluorescence sensors with excitation at this wavelength easy. Carious lesions, calculus and plaque have been measured using a self build fluorescence camera using GaN-diodes for illumination at 405nm. Further, emission spectra under this excitation were recorded. For the latter purpose freshly extracted teeth were used. It has been found that already in the case of an initial carious lesion red porphyrin-fluorescence is emitted whereas it is absent in healthy enamel. In already brown coloured carious lesions the emission bands of porphyrin are present but the observed overall fluorescence intensity is lower, probably due to the absorption of the fluorescence by the carious defect itself. In dental calculus, dental plaque and subgingival concrements porphyrin originated luminescence was found as well. Since in these cases the emission spectra differ slightly it can be concluded that they originate from different types of porphyrins and thus also from different bacteria. These results show that this fluorescence technique can be a promising method to diagnose carious lesions, calculus and plaque.

  13. Evaluation of the application of chemical shift for the detection of lipid in brain lesion

    Energy Technology Data Exchange (ETDEWEB)

    Lim, C.J. [Department of Biomedical Imaging, Faculty of Medicine, University of Malaya Medical Centre, Kuala Lumpur (Malaysia); Ng, K.H., E-mail: ngkh@um.edu.m [Department of Biomedical Imaging, Faculty of Medicine, University of Malaya Medical Centre, Kuala Lumpur (Malaysia); Ramli, N.; Azman, R.R. [Department of Biomedical Imaging, Faculty of Medicine, University of Malaya Medical Centre, Kuala Lumpur (Malaysia)

    2011-02-15

    Non-invasive detection of the presence of lipids is particularly important in staging of intracranial tumours. Presence of lipid peak in aggressive intracranial tumours has been reported widely using MR spectroscopy. However this method has limitation due to long imaging time and artefacts formed by adjacent bones. Chemical shift MR imaging (with has shorter imaging time) is an alternative method that had been used to detect presence of lipid in vivo by means of signal intensity loss. The purpose of this study was to evaluate gradient echo in- and opposed-phase chemical shift pulse sequences for detection of lipid elements in brain lesion. Ten cylindered phantoms measuring 3 x 3 cm were filled with various mixtures of lipid and water: 0-90% lipid, in 10% step by weight. The gradient echo in- and opposed-phase chemical shift sequences were performed using a 1.5 T MRI (Magnetom Vision, Siemens) with a head coil. In addition, we performed MRI and chemical shift studies on 32 patients with brain lesion. We then analysed the association between out of phase intensity value and classification of the lesions. For phantom containing 50% lipid, maximum signal loss on opposed-phase images was observed. There were significant differences between in- and opposed-phase lipid-water phantom images (P = 0.0054). Most of the benign lesions fall into the positive out of phase intensity value, and malignant lesions fall into negative out of phase intensity value. We conclude that chemical shift artefact can be applied in detecting and characterising lipid elements in brain lesion.

  14. Evaluation of the application of chemical shift for the detection of lipid in brain lesion

    International Nuclear Information System (INIS)

    Lim, C.J.; Ng, K.H.; Ramli, N.; Azman, R.R.

    2011-01-01

    Non-invasive detection of the presence of lipids is particularly important in staging of intracranial tumours. Presence of lipid peak in aggressive intracranial tumours has been reported widely using MR spectroscopy. However this method has limitation due to long imaging time and artefacts formed by adjacent bones. Chemical shift MR imaging (with has shorter imaging time) is an alternative method that had been used to detect presence of lipid in vivo by means of signal intensity loss. The purpose of this study was to evaluate gradient echo in- and opposed-phase chemical shift pulse sequences for detection of lipid elements in brain lesion. Ten cylindered phantoms measuring 3 x 3 cm were filled with various mixtures of lipid and water: 0-90% lipid, in 10% step by weight. The gradient echo in- and opposed-phase chemical shift sequences were performed using a 1.5 T MRI (Magnetom Vision, Siemens) with a head coil. In addition, we performed MRI and chemical shift studies on 32 patients with brain lesion. We then analysed the association between out of phase intensity value and classification of the lesions. For phantom containing 50% lipid, maximum signal loss on opposed-phase images was observed. There were significant differences between in- and opposed-phase lipid-water phantom images (P = 0.0054). Most of the benign lesions fall into the positive out of phase intensity value, and malignant lesions fall into negative out of phase intensity value. We conclude that chemical shift artefact can be applied in detecting and characterising lipid elements in brain lesion.

  15. Automated multi-lesion detection for referable diabetic retinopathy in indigenous health care.

    Science.gov (United States)

    Pires, Ramon; Carvalho, Tiago; Spurling, Geoffrey; Goldenstein, Siome; Wainer, Jacques; Luckie, Alan; Jelinek, Herbert F; Rocha, Anderson

    2015-01-01

    Diabetic Retinopathy (DR) is a complication of diabetes mellitus that affects more than one-quarter of the population with diabetes, and can lead to blindness if not discovered in time. An automated screening enables the identification of patients who need further medical attention. This study aimed to classify retinal images of Aboriginal and Torres Strait Islander peoples utilizing an automated computer-based multi-lesion eye screening program for diabetic retinopathy. The multi-lesion classifier was trained on 1,014 images from the São Paulo Eye Hospital and tested on retinal images containing no DR-related lesion, single lesions, or multiple types of lesions from the Inala Aboriginal and Torres Strait Islander health care centre. The automated multi-lesion classifier has the potential to enhance the efficiency of clinical practice delivering diabetic retinopathy screening. Our program does not necessitate image samples for training from any specific ethnic group or population being assessed and is independent of image pre- or post-processing to identify retinal lesions. In this Aboriginal and Torres Strait Islander population, the program achieved 100% sensitivity and 88.9% specificity in identifying bright lesions, while detection of red lesions achieved a sensitivity of 67% and specificity of 95%. When both bright and red lesions were present, 100% sensitivity with 88.9% specificity was obtained. All results obtained with this automated screening program meet WHO standards for diabetic retinopathy screening.

  16. Management for BI-RADS category 3 lesions detected in preoperative breast MR imaging of breast cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Gweon, Hye Mi [Seoul National University College of Medicine, Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Gangnam Severance Hospital, Yonsei University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Cho, Nariya; Kim, Soo-Yeon [Seoul National University College of Medicine, Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Koo, Hye Ryoung [Hanyang University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seo, Mirinae [Kyung Hee University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Chu, Ajung [Seoul National University College of Medicine, Boramae Medical Center, Department of Radiology, Seoul (Korea, Republic of); Son, Eun Ju [Gangnam Severance Hospital, Yonsei University College of Medicine, Department of Radiology, Seoul (Korea, Republic of)

    2017-08-15

    To retrospectively evaluate characteristics of and determine appropriate follow-up recommendations for BI-RADS category 3 lesions detected in preoperative MRI of breast cancer patients. BI-RADS category 3 assessments were identified from the breast MRI database for 5,110 consecutive breast cancer patients who had undergone preoperative MRI and surgery. Patient and lesion characteristics, malignancy rate, and interval between lesion detection and cancer diagnosis were analysed. Histopathological results or imaging at or after 2-year follow-up were used as reference standards. Of the 626 lesions, morphological features included a single focus in 26.5% (n = 166), multiple foci in 47.1% (n = 295), mass in 21.7% (n = 136) and non-mass enhancement in 4.6% (n = 29). Cancer was found in 0.8% (5/626) at a median interval of 50 months (range, 29-66 months). Malignancy rate according to morphological feature was: 1.8% (3/166) in a single focus, 0.7% (1/136) in mass and 3.4% (1/29) in non-mass enhancement. All detected cancers were stage 0 or IA. Annual follow-up might be adequate for BI-RADS category 3 lesions detected at preoperative MRI because of the 0.8% (5/626) malignancy rate, long interval between lesion detection and cancer diagnosis, and early stage of diagnosed cancers. (orig.)

  17. Comparative analysis of MR sequences to detect structural brain lesions in tuberous sclerosis

    International Nuclear Information System (INIS)

    Pinto Gama, Hugo Pereira; Campos Meirelles, Rogerio Goncalves de; Mendonca do Rego, Jose Iram; Rocha, Antonio Jose da; Silva, Carlos Jorge da; Braga, Flavio Tulio; Martins Maia, Antonio Carlos; Lederman, Henrique Manoel

    2006-01-01

    Tuberous sclerosis (TS) is a neurocutaneous genetically inherited disease with variable penetrance characterized by dysplasias and hamartomas affecting multiple organs. MR is the imaging method of choice to demonstrate structural brain lesions in TS. To compare MR sequences and determine which is most useful for the demonstration of each type of brain lesion in TS patients. We reviewed MR scans of 18 TS patients for the presence of cortical tubers, white matter lesions (radial bands), subependymal nodules, and subependymal giant cell astrocytoma (SGCA) on the following sequences: (1) T1-weighted spin-echo (T1 SE) images before and after gadolinium (Gd) injection; (2) nonenhanced T1 SE sequence with an additional magnetization transfer contrast medium pulse on resonance (T1 SE/MTC); and (3) fluid-attenuated inversion recovery (FLAIR) sequence. Cortical tubers were found in significantly (P<0.05) larger numbers and more conspicuously in FLAIR and T1 SE/MTC sequences. The T1 SE/MTC sequence was far superior to other methods in detecting white matter lesions (P<0.01). There was no significant difference between the T1 SE/MTC and T1 SE (before and after Gd injection) sequences in the detection of subependymal nodules; FLAIR sequence showed less sensitivity than the others in identifying the nodules. T1 SE sequences after Gd injection demonstrated better the limits of the SGCA. We demonstrated the importance of appropriate MRI sequences for diagnosis of the most frequent brain lesions in TS. Our study reinforces the fact that each sequence has a particular application according to the type of TS lesion. Gd injection might be useful in detecting SGCA; however, the parameters of size and location are also important for a presumptive diagnosis of these tumors. (orig.)

  18. Evaluation of colonic lesions and pitfalls in CT colonography: A systematic approach based on morphology, attenuation and mobility

    International Nuclear Information System (INIS)

    Mang, Thomas; Gryspeerdt, Stefaan; Schima, Wolfgang; Lefere, Philippe

    2013-01-01

    Computed tomographic colonography is a reliable technique for the detection and classification of neoplastic and non-neoplastic lesions of the colon. It is based on a thin-section CT dataset of the cleansed and air-distended colon, acquired in prone and supine position. Two-dimensional and 3D projections are used in combination for image interpretation. The evaluation of CT colonography datasets is based on two steps, lesion perception to detect a polyp candidate and image interpretation to correctly characterize colonic filling defects. A thorough knowledge of the morphologic and attenuation characteristics of common colonic lesions and artifacts facilitates characterization of the findings. The purpose of this review article is to give an overview of the key CT colonographic imaging criteria to correctly characterize common colorectal lesions and to identify typical pitfalls and pseudolesions

  19. Temporal characteristics of radiologists’ and novices’ lesion detection in viewing medical images presented rapidly and sequentially

    Directory of Open Access Journals (Sweden)

    Ryoichi Nakashima

    2016-10-01

    Full Text Available Although viewing multiple stacks of medical images presented on a display is a relatively new but useful medical task, little is known about this task. Particularly, it is unclear how radiologists search for lesions in this type of image reading. When viewing cluttered and dynamic displays, continuous motion itself does not capture attention. Thus, it is effective for the target detection that observers’ attention is captured by the onset signal of a suddenly appearing target among the continuously moving distractors (i.e., a passive viewing strategy. This can be applied to stack viewing tasks, because lesions often show up as transient signals in medical images which are sequentially presented simulating a dynamic and smoothly transforming image progression of organs. However, it is unclear whether observers can detect a target when the target appears at the beginning of a sequential presentation where the global apparent motion onset signal (i.e., signal of the initiation of the apparent motion by sequential presentation occurs. We investigated the ability of radiologists to detect lesions during such tasks by comparing the performances of radiologists and novices. Results show that overall performance of radiologists is better than novices. Furthermore, the temporal locations of lesions in CT image sequences, i.e., when a lesion appears in an image sequence, does not affect the performance of radiologists, whereas it does affect the performance of novices. Results indicate that novices have greater difficulty in detecting a lesion appearing early than late in the image sequence. We suggest that radiologists have other mechanisms to detect lesions in medical images with little attention which novices do not have. This ability is critically important when viewing rapid sequential presentations of multiple CT images, such as stack viewing tasks.

  20. Reporting and management of breast lesions detected using MRI

    International Nuclear Information System (INIS)

    Dall, B.J.G.; Vinnicombe, S.; Gilbert, F.J.

    2011-01-01

    Magnetic resonance imaging (MRI) is the most accurate technique for diagnosing and delineating the extent of both invasive and in-situ breast cancer and is increasingly being used as part of the preoperative work-up to assess the local extent of disease. It is proving invaluable in providing information that allows successful single-stage surgery. An inevitable consequence of the high sensitivity of MRI is that it will identify additional lesions that may or may not represent significant extra disease. This may complicate and delay the preoperative process. This paper outlines a strategy for managing MRI-detected lesions to optimize the benefits of breast MRI as a local staging tool while minimizing the false-positive diagnoses. It discusses the importance of good technique to reduce the number of indeterminate lesions. Methods to refine the patient pathway to minimize delays are discussed. The format of MRI reporting is discussed in detail as is the usefulness of discussion of cases at multidisciplinary meetings. Illustrative cases are used to clarify the points made.

  1. MRI detection of hypointense brain lesions in patients with multiple sclerosis: T1 spin-echo vs. gradient-echo

    Energy Technology Data Exchange (ETDEWEB)

    Dupuy, Sheena L.; Tauhid, Shahamat; Kim, Gloria; Chu, Renxin; Tummala, Subhash [Departments of Neurology, Brigham and Women' s Hospital, Laboratory for Neuroimaging Research, Partners MS Center, Harvard Medical School, Boston, MA (United States); Hurwitz, Shelley [Departments of Medicine, Brigham and Women' s Hospital, Harvard Medical School, Boston, MA (United States); Bakshi, Rohit, E-mail: rbakshi@bwh.harvard.edu [Departments of Neurology, Brigham and Women' s Hospital, Laboratory for Neuroimaging Research, Partners MS Center, Harvard Medical School, Boston, MA (United States); Departments of Radiology, Brigham and Women' s Hospital, Harvard Medical School, Boston, MA (United States)

    2015-08-15

    Highlights: • Compared T1SE and T1GE in detecting hypointense brain lesions in MS patients. • T1GE detected a higher cerebral lesion volume and number than T1SE. • T1SE correlated significantly with disability, while T1GE did not. • Hypointense lesions on T1SE and T1GE are not interchangeable in patients with MS. - Abstract: Objective: Compare T1 spin-echo (T1SE) and T1 gradient-echo (T1GE) sequences in detecting hypointense brain lesions in multiple sclerosis (MS). Background: Chronic hypointense lesions on T1SE MRI scans are a surrogate of severe demyelination and axonal loss in MS. The role of T1GE images in the detection of such lesions has not been clarified. Design/methods: In 45 patients with MS [Expanded Disability Status Scale (EDSS) score (mean ± SD) 3.5 ± 2.0; 37 relapsing-remitting (RR); 8 secondary progressive (SP)], cerebral T1SE, T1GE, and T2-weighted fluid-attenuated inversion-recovery (FLAIR) images were acquired on a 1.5 T MRI scanner. Images were re-sampled to axial 5 mm slices before directly comparing lesion detectability using Jim (v.7, Xinapse Systems). Statistical methods included Wilcoxon signed rank tests to compare sequences and Spearman correlations to test associations. Results: Considering the entire cohort, T1GE detected a higher lesion volume (5.90 ± 6.21 vs. 4.17 ± 4.84 ml, p < 0.0001) and higher lesion number (27.82 ± 20.66 vs. 25.20 ± 20.43, p < 0.05) than T1SE. Lesion volume differences persisted when considering RR and SP patients separately (both p < 0.01). A higher lesion number by T1GE was seen only in the RR group (p < 0.05). When comparing correlations between lesion volume and overall neurologic disability (EDSS score), T1SE correlated with EDSS (Spearman r = 0.29, p < 0.05) while T1GE (r = 0.23, p = 0.13) and FLAIR (r = 0.24, p = 0.12) did not. Conclusion: Our data suggest that hypointense lesions on T1SE and T1GE are not interchangeable in patients with MS. Based on these results, we hypothesize that T1GE

  2. MRI detection of hypointense brain lesions in patients with multiple sclerosis: T1 spin-echo vs. gradient-echo

    International Nuclear Information System (INIS)

    Dupuy, Sheena L.; Tauhid, Shahamat; Kim, Gloria; Chu, Renxin; Tummala, Subhash; Hurwitz, Shelley; Bakshi, Rohit

    2015-01-01

    Highlights: • Compared T1SE and T1GE in detecting hypointense brain lesions in MS patients. • T1GE detected a higher cerebral lesion volume and number than T1SE. • T1SE correlated significantly with disability, while T1GE did not. • Hypointense lesions on T1SE and T1GE are not interchangeable in patients with MS. - Abstract: Objective: Compare T1 spin-echo (T1SE) and T1 gradient-echo (T1GE) sequences in detecting hypointense brain lesions in multiple sclerosis (MS). Background: Chronic hypointense lesions on T1SE MRI scans are a surrogate of severe demyelination and axonal loss in MS. The role of T1GE images in the detection of such lesions has not been clarified. Design/methods: In 45 patients with MS [Expanded Disability Status Scale (EDSS) score (mean ± SD) 3.5 ± 2.0; 37 relapsing-remitting (RR); 8 secondary progressive (SP)], cerebral T1SE, T1GE, and T2-weighted fluid-attenuated inversion-recovery (FLAIR) images were acquired on a 1.5 T MRI scanner. Images were re-sampled to axial 5 mm slices before directly comparing lesion detectability using Jim (v.7, Xinapse Systems). Statistical methods included Wilcoxon signed rank tests to compare sequences and Spearman correlations to test associations. Results: Considering the entire cohort, T1GE detected a higher lesion volume (5.90 ± 6.21 vs. 4.17 ± 4.84 ml, p < 0.0001) and higher lesion number (27.82 ± 20.66 vs. 25.20 ± 20.43, p < 0.05) than T1SE. Lesion volume differences persisted when considering RR and SP patients separately (both p < 0.01). A higher lesion number by T1GE was seen only in the RR group (p < 0.05). When comparing correlations between lesion volume and overall neurologic disability (EDSS score), T1SE correlated with EDSS (Spearman r = 0.29, p < 0.05) while T1GE (r = 0.23, p = 0.13) and FLAIR (r = 0.24, p = 0.12) did not. Conclusion: Our data suggest that hypointense lesions on T1SE and T1GE are not interchangeable in patients with MS. Based on these results, we hypothesize that T1GE

  3. Contralateral lesions detected by preoperative MRI in patients with recently diagnosed breast cancer: Application of MR CAD in differentiation of benign and malignant lesions

    International Nuclear Information System (INIS)

    Cho, Nariya; Kim, Sun Mi; Park, Jeong Seon; Jang, Mijung; Kim, Soo-Yeon; Chang, Jung Min; Moon, Woo Kyung

    2012-01-01

    Objectives: To retrospectively investigate the added value of kinetic features measured by computer-aided diagnosis (CAD) for differentiating benign and malignant contralateral breast lesions detected by preoperative MRI in breast cancer patients. Methods: This study was approved by our institutional review board, and the requirement for informed consent was waived. Fifty-two breast MR images and their CAD kinetic features were obtained for 52 consecutive breast cancer patients with contralateral breast lesions detected by preoperative MRI and confirmed by excision (23 cancers and 29 benign lesions). Three experienced radiologists independently reviewed the MR images without CAD information and assessed probabilities of malignancy. Four weeks later, these probabilities were reanalyzed using stored CAD data. Diagnostic performances and detection rates of delayed washout components were compared between interpretations without and with CAD for each reader. Results: Use of MR CAD increased detection of washout component by 2.4- to 3.7-fold than visual assessment for enhancing contralateral lesions, which increased sensitivity (91% vs. 87% in reader 1; 96% vs. 74% in reader 2; 91% vs. 70% in reader 3) and decreased specificity, but statistical significance was only found for decreased specificity in one reader (52% vs. 28%, P = 0.039), and overall performance (areas under ROC curves 0.672 vs. 0.616 in reader 1; 0.624 vs. 0.603 in reader 2; 0.706 vs. 0.590 in reader 3) remained unimproved. Conclusion: Addition of MR CAD increased sensitivity and decreased specificity than radiologist's assessment alone for differentiating benign and malignant contralateral lesions in breast cancer patients and overall performance remained unimproved.

  4. Review and management of breast lesions detected with breast tomosynthesis but not visible on mammography and ultrasonography.

    Science.gov (United States)

    Taskin, Fusun; Durum, Yasemin; Soyder, Aykut; Unsal, Alparslan

    2017-12-01

    Background Breast tomosynthesis is more sensitive than mammography and can detect lesions that are not always visible with conventional methods such as digital mammography (MG) and ultrasonography (US). No standardized approach is available for the management of lesions that are detectable with tomosynthesis but are not visible on MG or US. Purpose To review suspicious breast lesions detected with tomosynthesis but not visible on two-dimensional (2D) MG or US and to determine the management options for these lesions. Material and Methods Ethical committee approval was obtained. The radiological records, biopsy or surgery results, and follow-up findings of 107 patients who had a tomosynthesis-positive but MG- or US-negative breast lesion between 2011 and 2016 were retrospectively evaluated. Results Of 107 lesions visible only with tomosynthesis, 74% were architectural distortions and 26% were asymmetrical opacities. All patients underwent magnetic resonance imaging (MRI) for further evaluation. Among the 48 (45%) MRI-negative lesions, none had a suspicious alteration during the follow-up period. Among the MRI-positive lesions, 28% of the 50 architectural distortions and 11% of the nine asymmetrical opacities were malignant. Conclusion Given the inherent high false-positive rate of breast tomosynthesis, breast MRI prior to biopsy may reduce the number of unnecessary biopsies for suspicious breast lesions that are tomosynthesis-positive only.

  5. A new automated quantification algorithm for the detection and evaluation of focal liver lesions with contrast-enhanced ultrasound.

    Science.gov (United States)

    Gatos, Ilias; Tsantis, Stavros; Spiliopoulos, Stavros; Skouroliakou, Aikaterini; Theotokas, Ioannis; Zoumpoulis, Pavlos; Hazle, John D; Kagadis, George C

    2015-07-01

    Detect and classify focal liver lesions (FLLs) from contrast-enhanced ultrasound (CEUS) imaging by means of an automated quantification algorithm. The proposed algorithm employs a sophisticated segmentation method to detect and contour focal lesions from 52 CEUS video sequences (30 benign and 22 malignant). Lesion detection involves wavelet transform zero crossings utilization as an initialization step to the Markov random field model toward the lesion contour extraction. After FLL detection across frames, time intensity curve (TIC) is computed which provides the contrast agents' behavior at all vascular phases with respect to adjacent parenchyma for each patient. From each TIC, eight features were automatically calculated and employed into the support vector machines (SVMs) classification algorithm in the design of the image analysis model. With regard to FLLs detection accuracy, all lesions detected had an average overlap value of 0.89 ± 0.16 with manual segmentations for all CEUS frame-subsets included in the study. Highest classification accuracy from the SVM model was 90.3%, misdiagnosing three benign and two malignant FLLs with sensitivity and specificity values of 93.1% and 86.9%, respectively. The proposed quantification system that employs FLLs detection and classification algorithms may be of value to physicians as a second opinion tool for avoiding unnecessary invasive procedures.

  6. Detection of oral early cancerous lesion by using polarization-sensitive optical coherence tomography: mice model

    Science.gov (United States)

    Lee, Hong-Yi; Chen, Ping-Hsien; Lee, Tzu-Han; Chang, Kuo-Wei; Kuo, Wen-Chuan

    2018-02-01

    Oral cancer is the 11th most common cancer worldwide, especially in a male adult. The median age of death in oral cancer was 55 years, 10-20 years earlier than other cancers. Presently, oral cancer is often found in late stage, because the lesion is often flat in early stage and is difficult to diagnose under traditional white light imaging. The only definitive method for determining cancer is an invasive biopsy and then using histology examination. How to detect precancerous lesions or early malignant lesions is an important issue for improving prognosis of oral cancer. Optical coherence tomography (OCT) is a new optical tool for diagnosing early malignant lesions in the skin or gastrointestinal tract recently. Here we report a new method for detecting precancerous or early malignant oral lesions by using swept source polarization-sensitive optical coherence tomography (PS-OCT) with center-wavelength 1310 nm, bandwidth 110 nm and 100 kHz swept rate. We used all single-mode fiber design to detect the change of birefringence information in the epithelium structure. This system has an advantage that enables measurement of backscattered intensity and birefringence simultaneously with only one A-scan per transverse location. In preliminary result, we computed the slope of the every A-scan signal in tissue part using a linear-curve fitting in backscattered intensity and birefringence on the enface. In this research, we used an oral cancer mice model for observing the change of structure and birefringence properties in different stages of oral cancer mice. We presented the parametric enface imaging that can detect the early oral malignant lesions.

  7. Automated multi-lesion detection for referable diabetic retinopathy in indigenous health care.

    Directory of Open Access Journals (Sweden)

    Ramon Pires

    Full Text Available Diabetic Retinopathy (DR is a complication of diabetes mellitus that affects more than one-quarter of the population with diabetes, and can lead to blindness if not discovered in time. An automated screening enables the identification of patients who need further medical attention. This study aimed to classify retinal images of Aboriginal and Torres Strait Islander peoples utilizing an automated computer-based multi-lesion eye screening program for diabetic retinopathy. The multi-lesion classifier was trained on 1,014 images from the São Paulo Eye Hospital and tested on retinal images containing no DR-related lesion, single lesions, or multiple types of lesions from the Inala Aboriginal and Torres Strait Islander health care centre. The automated multi-lesion classifier has the potential to enhance the efficiency of clinical practice delivering diabetic retinopathy screening. Our program does not necessitate image samples for training from any specific ethnic group or population being assessed and is independent of image pre- or post-processing to identify retinal lesions. In this Aboriginal and Torres Strait Islander population, the program achieved 100% sensitivity and 88.9% specificity in identifying bright lesions, while detection of red lesions achieved a sensitivity of 67% and specificity of 95%. When both bright and red lesions were present, 100% sensitivity with 88.9% specificity was obtained. All results obtained with this automated screening program meet WHO standards for diabetic retinopathy screening.

  8. Detection of infarct lesions from single MRI modality using inconsistency between voxel intensity and spatial location--a 3-D automatic approach.

    Science.gov (United States)

    Shen, Shan; Szameitat, André J; Sterr, Annette

    2008-07-01

    Detection of infarct lesions using traditional segmentation methods is always problematic due to intensity similarity between lesions and normal tissues, so that multispectral MRI modalities were often employed for this purpose. However, the high costs of MRI scan and the severity of patient conditions restrict the collection of multiple images. Therefore, in this paper, a new 3-D automatic lesion detection approach was proposed, which required only a single type of anatomical MRI scan. It was developed on a theory that, when lesions were present, the voxel-intensity-based segmentation and the spatial-location-based tissue distribution should be inconsistent in the regions of lesions. The degree of this inconsistency was calculated, which indicated the likelihood of tissue abnormality. Lesions were identified when the inconsistency exceeded a defined threshold. In this approach, the intensity-based segmentation was implemented by the conventional fuzzy c-mean (FCM) algorithm, while the spatial location of tissues was provided by prior tissue probability maps. The use of simulated MRI lesions allowed us to quantitatively evaluate the performance of the proposed method, as the size and location of lesions were prespecified. The results showed that our method effectively detected lesions with 40-80% signal reduction compared to normal tissues (similarity index > 0.7). The capability of the proposed method in practice was also demonstrated on real infarct lesions from 15 stroke patients, where the lesions detected were in broad agreement with true lesions. Furthermore, a comparison to a statistical segmentation approach presented in the literature suggested that our 3-D lesion detection approach was more reliable. Future work will focus on adapting the current method to multiple sclerosis lesion detection.

  9. Automated Whole-Body Bone Lesion Detection for Multiple Myeloma on 68Ga-Pentixafor PET/CT Imaging Using Deep Learning Methods.

    Science.gov (United States)

    Xu, Lina; Tetteh, Giles; Lipkova, Jana; Zhao, Yu; Li, Hongwei; Christ, Patrick; Piraud, Marie; Buck, Andreas; Shi, Kuangyu; Menze, Bjoern H

    2018-01-01

    The identification of bone lesions is crucial in the diagnostic assessment of multiple myeloma (MM). 68 Ga-Pentixafor PET/CT can capture the abnormal molecular expression of CXCR-4 in addition to anatomical changes. However, whole-body detection of dozens of lesions on hybrid imaging is tedious and error prone. It is even more difficult to identify lesions with a large heterogeneity. This study employed deep learning methods to automatically combine characteristics of PET and CT for whole-body MM bone lesion detection in a 3D manner. Two convolutional neural networks (CNNs), V-Net and W-Net, were adopted to segment and detect the lesions. The feasibility of deep learning for lesion detection on 68 Ga-Pentixafor PET/CT was first verified on digital phantoms generated using realistic PET simulation methods. Then the proposed methods were evaluated on real 68 Ga-Pentixafor PET/CT scans of MM patients. The preliminary results showed that deep learning method can leverage multimodal information for spatial feature representation, and W-Net obtained the best result for segmentation and lesion detection. It also outperformed traditional machine learning methods such as random forest classifier (RF), k -Nearest Neighbors ( k -NN), and support vector machine (SVM). The proof-of-concept study encourages further development of deep learning approach for MM lesion detection in population study.

  10. Automated Whole-Body Bone Lesion Detection for Multiple Myeloma on 68Ga-Pentixafor PET/CT Imaging Using Deep Learning Methods

    Directory of Open Access Journals (Sweden)

    Lina Xu

    2018-01-01

    Full Text Available The identification of bone lesions is crucial in the diagnostic assessment of multiple myeloma (MM. 68Ga-Pentixafor PET/CT can capture the abnormal molecular expression of CXCR-4 in addition to anatomical changes. However, whole-body detection of dozens of lesions on hybrid imaging is tedious and error prone. It is even more difficult to identify lesions with a large heterogeneity. This study employed deep learning methods to automatically combine characteristics of PET and CT for whole-body MM bone lesion detection in a 3D manner. Two convolutional neural networks (CNNs, V-Net and W-Net, were adopted to segment and detect the lesions. The feasibility of deep learning for lesion detection on 68Ga-Pentixafor PET/CT was first verified on digital phantoms generated using realistic PET simulation methods. Then the proposed methods were evaluated on real 68Ga-Pentixafor PET/CT scans of MM patients. The preliminary results showed that deep learning method can leverage multimodal information for spatial feature representation, and W-Net obtained the best result for segmentation and lesion detection. It also outperformed traditional machine learning methods such as random forest classifier (RF, k-Nearest Neighbors (k-NN, and support vector machine (SVM. The proof-of-concept study encourages further development of deep learning approach for MM lesion detection in population study.

  11. Positron emission mammography (PEM): Effect of activity concentration, object size, and object contrast on phantom lesion detection

    International Nuclear Information System (INIS)

    MacDonald, Lawrence R.; Wang, Carolyn L.; Eissa, Marna; Haseley, David; Kelly, Mary M.; Liu, Franklin; Parikh, Jay R.; Beatty, J. David; Rogers, James V.

    2012-01-01

    Purpose: To characterize the relationship between lesion detection sensitivity and injected activity as a function of lesion size and contrast on the PEM (positron emission mammography) Flex Solo II scanner using phantom experiments. Methods: Phantom lesions (spheres 4, 8, 12, 16, and 20 mm diameter) were randomly located in uniform background. Sphere activity concentrations were 3 to 21 times the background activity concentration (BGc). BGc was a surrogate for injected activity; BGc ranged from 0.44–4.1 kBq/mL, corresponding to 46–400 MBq injections. Seven radiologists read 108 images containing zero, one, or two spheres. Readers used a 5-point confidence scale to score the presence of spheres. Results: Sensitivity was 100% for lesions ≥12 mm under all conditions except for one 12 mm sphere with the lowest contrast and lowest BGc (60% sensitivity). Sensitivity was 100% for 8 mm spheres when either contrast or BGc was high, and 100% for 4 mm spheres only when both contrast and BGc were highest. Sphere contrast recovery coefficients (CRC) were 49%, 34%, 26%, 14%, and 2.8% for the largest to smallest spheres. Cumulative specificity was 98%. Conclusions: Phantom lesion detection sensitivity depends more on sphere size and contrast than on BGc. Detection sensitivity remained ≥90% for injected activities as low as 100 MBq, for lesions ≥8 mm. Low CRC in 4 mm objects results in moderate detection sensitivity even for 400 MBq injected activity, making it impractical to optimize injected activity for such lesions. Low CRC indicates that when lesions <8 mm are observed on PEM images they are highly tracer avid with greater potential of clinical significance. High specificity (98%) suggests that image statistical noise does not lead to false positive findings. These results apply to the 85 mm thick object used to obtain them; lesion detectability should be better (worse) for thinner (thicker) objects based on the reduced (increased) influence of photon attenuation.

  12. Impact of variations in fatty liver on sonographic detection of focal hepatic lesions originally identified by CT

    International Nuclear Information System (INIS)

    Wu, Size; Tu, Rong; Nan, Ruixia; Liu, Guang Qing; Cui, Xiao Jing; Liang, Xian

    2016-01-01

    The aim of this study was to investigate the influence of variations in fatty liver on the ultrasonographic detection of focal liver lesions. A total of 229 patients with varying degrees of fatty liver and focal liver lesions and 200 patients with focal liver lesions but no fatty liver were randomly selected for inclusion in groups I and II, respectively. Findings of focal liver lesions identified on computed tomography were taken as the reference, and findings on ultrasonography were compared with them. The number of focal liver lesions in groups I and II were 501 and 413, respectively. The ultrasonographic detection rates of focal liver lesions in groups I and II were 86.8% (435/501) and 94.2% (389/413), respectively. Comparison of the detection of the focal lesions between patients with and without fatty liver or different grades of fatty liver were as follows: mild fatty liver (162/177) vs. liver without fat infiltration (389/413) (P=0.277); mild fatty liver (162/177) vs. moderate fatty liver (190/212) (P=0.604); mild fatty liver (162/177) vs. severe fatty liver (83/112) (P<0.001); moderate fatty liver (190/212) vs. liver without fat infiltration (389/413) (P=0.051); moderate fatty liver (190/212) vs. severe fatty liver (83/112) (P<0.001); severe fatty liver (83/112) vs. liver without fat infiltration (389/413) (P<0.001); and fatty liver (435/501) vs. liver without fat infiltration (389/413) (P<0.001). Mild and moderate fatty liver are not significantly associated with the visualization of the lesion, while severe fatty liver usually impairs the detection of focal lesions in the liver. If a patient with severe fatty liver is suspected to have a liver tumor, ultrasonography should only be chosen cautiously in case of a missed diagnosis

  13. Impact of variations in fatty liver on sonographic detection of focal hepatic lesions originally identified by CT

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Size; Tu, Rong; Nan, Ruixia; Liu, Guang Qing; Cui, Xiao Jing; Liang, Xian [Affiliated Hospital of Hainan Medical College, Haikou (China)

    2016-01-15

    The aim of this study was to investigate the influence of variations in fatty liver on the ultrasonographic detection of focal liver lesions. A total of 229 patients with varying degrees of fatty liver and focal liver lesions and 200 patients with focal liver lesions but no fatty liver were randomly selected for inclusion in groups I and II, respectively. Findings of focal liver lesions identified on computed tomography were taken as the reference, and findings on ultrasonography were compared with them. The number of focal liver lesions in groups I and II were 501 and 413, respectively. The ultrasonographic detection rates of focal liver lesions in groups I and II were 86.8% (435/501) and 94.2% (389/413), respectively. Comparison of the detection of the focal lesions between patients with and without fatty liver or different grades of fatty liver were as follows: mild fatty liver (162/177) vs. liver without fat infiltration (389/413) (P=0.277); mild fatty liver (162/177) vs. moderate fatty liver (190/212) (P=0.604); mild fatty liver (162/177) vs. severe fatty liver (83/112) (P<0.001); moderate fatty liver (190/212) vs. liver without fat infiltration (389/413) (P=0.051); moderate fatty liver (190/212) vs. severe fatty liver (83/112) (P<0.001); severe fatty liver (83/112) vs. liver without fat infiltration (389/413) (P<0.001); and fatty liver (435/501) vs. liver without fat infiltration (389/413) (P<0.001). Mild and moderate fatty liver are not significantly associated with the visualization of the lesion, while severe fatty liver usually impairs the detection of focal lesions in the liver. If a patient with severe fatty liver is suspected to have a liver tumor, ultrasonography should only be chosen cautiously in case of a missed diagnosis.

  14. Impact of variations in fatty liver on sonographic detection of focal hepatic lesions originally identified by CT

    Directory of Open Access Journals (Sweden)

    Size Wu

    2016-01-01

    Full Text Available Purpose: The aim of this study was to investigate the influence of variations in fatty liver on the ultrasonographic detection of focal liver lesions. Methods: A total of 229 patients with varying degrees of fatty liver and focal liver lesions and 200 patients with focal liver lesions but no fatty liver were randomly selected for inclusion in groups I and II, respectively. Findings of focal liver lesions identified on computed tomography were taken as the reference, and findings on ultrasonography were compared with them. Results: The number of focal liver lesions in groups I and II were 501 and 413, respectively. The ultrasonographic detection rates of focal liver lesions in groups I and II were 86.8% (435/501 and 94.2% (389/413, respectively. Comparison of the detection of the focal lesions between patients with and without fatty liver or different grades of fatty liver were as follows: mild fatty liver (162/177 vs. liver without fat infiltration (389/413 (P=0.277; mild fatty liver (162/177 vs. moderate fatty liver (190/212 (P=0.604; mild fatty liver (162/177 vs. severe fatty liver (83/112 (P<0.001; moderate fatty liver (190/212 vs. liver without fat infiltration (389/413 (P=0.051; moderate fatty liver (190/212 vs. severe fatty liver (83/112 (P<0.001; severe fatty liver (83/112 vs. liver without fat infiltration (389/413 (P<0.001; and fatty liver (435/501 vs. liver without fat infiltration (389/413 (P<0.001. Conclusion: Mild and moderate fatty liver are not significantly associated with the visualization of the lesion, while severe fatty liver usually impairs the detection of focal lesions in the liver. If a patient with severe fatty liver is suspected to have a liver tumor, ultrasonography should only be chosen cautiously in case of a missed diagnosis.

  15. Detection of early carious lesions using contrast enhancement with coherent light scattering (speckle imaging)

    International Nuclear Information System (INIS)

    Deana, A M; Jesus, S H C; Koshoji, N H; Bussadori, S K; Oliveira, M T

    2013-01-01

    Currently, dental caries still represent one of the chronic diseases with the highest prevalence and present in most countries. The interaction between light and teeth (absorption, scattering and fluorescence) is intrinsically connected to the constitution of the dental tissue. Decay induced mineral loss introduces a shift in the optical properties of the affected tissue; therefore, study of these properties may produce novel techniques aimed at the early diagnosis of carious lesions. Based on the optical properties of the enamel, we demonstrate the application of first-order spatial statistics in laser speckle imaging, allowing the detection of carious lesions in their early stages. A highlight of this noninvasive, non-destructive, real time and cost effective approach is that it allows a dentist to detect a lesion even in the absence of biofilm or moisture. (paper)

  16. Image covariance and lesion detectability in direct fan-beam x-ray computed tomography.

    Science.gov (United States)

    Wunderlich, Adam; Noo, Frédéric

    2008-05-21

    We consider noise in computed tomography images that are reconstructed using the classical direct fan-beam filtered backprojection algorithm, from both full- and short-scan data. A new, accurate method for computing image covariance is presented. The utility of the new covariance method is demonstrated by its application to the implementation of a channelized Hotelling observer for a lesion detection task. Results from the new covariance method and its application to the channelized Hotelling observer are compared with results from Monte Carlo simulations. In addition, the impact of a bowtie filter and x-ray tube current modulation on reconstruction noise and lesion detectability are explored for full-scan reconstruction.

  17. Image covariance and lesion detectability in direct fan-beam x-ray computed tomography

    International Nuclear Information System (INIS)

    Wunderlich, Adam; Noo, Frederic

    2008-01-01

    We consider noise in computed tomography images that are reconstructed using the classical direct fan-beam filtered backprojection algorithm, from both full- and short-scan data. A new, accurate method for computing image covariance is presented. The utility of the new covariance method is demonstrated by its application to the implementation of a channelized Hotelling observer for a lesion detection task. Results from the new covariance method and its application to the channelized Hotelling observer are compared with results from Monte Carlo simulations. In addition, the impact of a bowtie filter and x-ray tube current modulation on reconstruction noise and lesion detectability are explored for full-scan reconstruction

  18. Evaluation of capsule endoscopy to detect mucosal lesions associated with gastrointestinal bleeding in dogs.

    Science.gov (United States)

    Davignon, D L; Lee, A C Y; Johnston, A N; Bowman, D D; Simpson, K W

    2016-03-01

    The objective of this study was to examine the utility of capsule endoscopy to detect mucosal abnormalities in dogs with gastrointestinal haemorrhage. Capsules were administered to 2 healthy controls and 8 patients with gastrointestinal haemorrhage. Images were evaluated for quality, gastric emptying time, small intestinal transit time and presence of lesions. There were no adverse effects of capsule endoscopy in dogs weighing from 7·7 to 58 kg. The capsule traversed the entire gastrointestinal tract in 5 of 8 patients, with high quality images obtained in the stomach and small intestine. Gastric emptying time and small intestinal transit time ranged from 1 to 270 and 15 to 180 minutes, respectively. In 3 of 8 patients, the capsule remained in the stomach despite pro-kinetics. Gastric lesions included mild haemorrhage and pinpoint erosion (4 of 8), a mass (1) and thickened bleeding pyloric mucosa (2). Two of 3 dogs with capsule retention had gastric lesions. Intestinal lesions included a healing duodenal ulcer, abnormal villi, ileal ulceration and colonic bleeding. Lesions identified by capsule endoscopy were considered a significant source of haemorrhage in 4 of 7 dogs with active bleeding. The relevance of pinpoint gastric mucosal erosions to blood loss is unclear. Capsule endoscopy can enable the non-invasive detection of gastric and small intestinal mucosal lesions in dogs presenting for evaluation of gastrointestinal bleeding. © 2016 British Small Animal Veterinary Association.

  19. Automated detection of diabetic retinopathy lesions on ultrawidefield pseudocolour images.

    Science.gov (United States)

    Wang, Kang; Jayadev, Chaitra; Nittala, Muneeswar G; Velaga, Swetha B; Ramachandra, Chaithanya A; Bhaskaranand, Malavika; Bhat, Sandeep; Solanki, Kaushal; Sadda, SriniVas R

    2018-03-01

    We examined the sensitivity and specificity of an automated algorithm for detecting referral-warranted diabetic retinopathy (DR) on Optos ultrawidefield (UWF) pseudocolour images. Patients with diabetes were recruited for UWF imaging. A total of 383 subjects (754 eyes) were enrolled. Nonproliferative DR graded to be moderate or higher on the 5-level International Clinical Diabetic Retinopathy (ICDR) severity scale was considered as grounds for referral. The software automatically detected DR lesions using the previously trained classifiers and classified each image in the test set as referral-warranted or not warranted. Sensitivity, specificity and the area under the receiver operating curve (AUROC) of the algorithm were computed. The automated algorithm achieved a 91.7%/90.3% sensitivity (95% CI 90.1-93.9/80.4-89.4) with a 50.0%/53.6% specificity (95% CI 31.7-72.8/36.5-71.4) for detecting referral-warranted retinopathy at the patient/eye levels, respectively; the AUROC was 0.873/0.851 (95% CI 0.819-0.922/0.804-0.894). Diabetic retinopathy (DR) lesions were detected from Optos pseudocolour UWF images using an automated algorithm. Images were classified as referral-warranted DR with a high degree of sensitivity and moderate specificity. Automated analysis of UWF images could be of value in DR screening programmes and could allow for more complete and accurate disease staging. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  20. Proliferative changes in nonpalpable breast lesions detected by mammography

    International Nuclear Information System (INIS)

    Vega, A.; Delgado, A.; Ortega, E.; Garijo, F.; Mosquera, J.; Sogo, C.; Alvarez, A.

    2000-01-01

    To analyze retrospectively the radiological findings in nonpalpable breast lesions detected by mammography that lead to the performance of surgical biopsy, resulting in a histological diagnosis of proliferative breast disease with and without atypia. From two Spanish hospitals, 421 women with 429 biopsies indicative of the presence of proliferative breast disease with and without atypia were selected out of a total of 1252 surgical biopsies in nonpalpable lesions that proved to be benign. Age, personal and familial history of breast cancer, reason for requesting the mammography and radiological findings that had indicated the need for surgical biopsy were recorded for each patient. The diagnosis was proliferative breast disease (epithelial hyperplasia) in 347 women with 354 biopsies and atypical hyperplasia in the remaining 74 women with 75 biopsies, representing 28% and 6%, respectively, of the 1252 biopsies of lesions found to be benign. In 221 of the 354 cases of epithelial hyperplasia (62%) and 45 of the 75 cases of atypical hyperplasia (60%), the presence of calcifications was the most common radiological findings leading to biopsy (p<0.05). Parenchymal distortion, with or without calcifications, was the second most common radiological sign. The histological study revealed a close relationship between these proliferative events and radial scars. Calcifications are the radiological finding that most frequently indicate the need for surgical biopsy in nonpalpable lesions that results in a diagnosis of proliferative breast disease with and without atypia. (Author) 12 refs

  1. Computerized detection of multiple sclerosis candidate regions based on a level set method using an artificial neural network

    International Nuclear Information System (INIS)

    Kuwazuru, Junpei; Magome, Taiki; Arimura, Hidetaka; Yamashita, Yasuo; Oki, Masafumi; Toyofuku, Fukai; Kakeda, Shingo; Yamamoto, Daisuke

    2010-01-01

    Yamamoto et al. developed the system for computer-aided detection of multiple sclerosis (MS) candidate regions. In a level set method in their proposed method, they employed the constant threshold value for the edge indicator function related to a speed function of the level set method. However, it would be appropriate to adjust the threshold value to each MS candidate region, because the edge magnitudes in MS candidates differ from each other. Our purpose of this study was to develop a computerized detection of MS candidate regions in MR images based on a level set method using an artificial neural network (ANN). To adjust the threshold value for the edge indicator function in the level set method to each true positive (TP) and false positive (FP) region, we constructed the ANN. The ANN could provide the suitable threshold value for each candidate region in the proposed level set method so that TP regions can be segmented and FP regions can be removed. Our proposed method detected MS regions at a sensitivity of 82.1% with 0.204 FPs per slice and similarity index of MS candidate regions was 0.717 on average. (author)

  2. The evaluation of the effect of attenuation correction on lesion detectability in whole-body FDG-PET

    International Nuclear Information System (INIS)

    Tomemori, Takashi; Uno, Kimiichi; Oka, Takashi; Suzuki, Takayuki; Tomiyoshi, Katsumi; Jin Wu

    2004-01-01

    The aim of this study was to compare the attenuation corrected and non-corrected FDG-PET images in patients with malignant lesions and to evaluate the effect of attenuation correction on lesion detectability. A total of 71 persons with 112 malignant lesions was examined. All subjects fasted for at least 4 hours before PET study and whole-body PET imaging was performed 45 min after the intravenous administration of FDG (mean dose: 273.8 MBq). Emission scans of 6 min and post-injection transmission scans of 6 min per bed position were used. The intensity of lesion uptake in FDG-PET image was visually classified into 3 grades; grade 2=the lesion was clearly identified in the maximum intensity projection (MIP) image of FDG-PET, grade 1=the lesion was not identified in MIP image but it can be identified in coronal image, grade 0=there was no contrast between lesion and background in both MIP and coronal image. Ninety-eight lesions (87.5%) were classified into same grade in both attenuation corrected and non-corrected image, but in 11 lesions (9.8%) attenuation corrected image was better lesion visualization than non-corrected image. All lesions divided between the primary lesions and the metastatic lesions. In 50 primary lesions, 43 lesions were depicted in both attenuation corrected and non-corrected image and other 7 lesions were not in both image. In 62 metastatic lesions, 50 lesions (80.7%) were classified into same grade in both attenuation corrected and non-corrected image, but in 10 lesions (16.1%) attenuation corrected image were better lesion visualization than non-corrected image. In the most cases, the lesions were depicted in both attenuation corrected and non-corrected image. In the primary lesions, the lesion detectability between attenuation corrected and non-corrected image was similar. But in some cases with the metastatic lesions, attenuation corrected image were better lesion visualization than non-corrected image. For asymptomatic patients, non

  3. Postmortem verification of MS cortical lesion detection with 3D DIR

    NARCIS (Netherlands)

    Seewann, A.M.; Kooi, E.J.; Roosendaal, S.D.; Pouwels, P.J.W.; Wattjes, M.P.; van der Valk, P.; Barkhof, F.; Polman, C.H.; Geurts, J.J.G.

    2012-01-01

    Objective: To assess the sensitivity and specificity of 3D double inversion recovery (DIR) MRI for detecting multiple sclerosis (MS) cortical lesions (CLs) using a direct postmortem MRI to histopathology comparison. Methods: Single-slab 3D DIR and 3D fluid-attenuated inversion recovery (FLAIR)

  4. Real-time virtual sonography (RVS)-guided vacuum-assisted breast biopsy for lesions initially detected with breast MRI.

    Science.gov (United States)

    Uematsu, Takayoshi

    2013-12-01

    To report on our initial experiences with a new method of real-time virtual sonography (RVS)-guided 11-gauge vacuum-assisted breast biopsy for lesions that were initially detected with breast MRI. RVS-guided 11-gauge vacuum-assisted biopsy is performed when a lesion with suspicious characteristics is initially detected with breast MRI and is occult on mammography, sonography, and physical examination. Live sonographic images were co-registered to the previously loaded second-look spine contrast-enhanced breast MRI volume data to correlate the sonography and MR images. Six lesions were examined in six consecutive patients scheduled to undergo RVS-guided 11-gauge vacuum-assisted biopsy. One patient was removed from the study because of non-visualization of the lesion in the second-look spine contrast-enhanced breast MRI. Five patients with non-mass enhancement lesions were biopsied. The lesions ranged in size from 9 to 13 mm (mean 11 mm). The average procedural time, including the sonography and MR image co-registration time, was 25 min. All biopsies resulted in tissue retrieval. One was fibroadenomatous nodules, and those of four were fibrocystic changes. There were no complications during or after the procedures. RVS-guided 11-gauge vacuum-assisted breast biopsies provide a safe and effective method for the examination of suspicious lesions initially detected with MRI.

  5. Detection of atherosclerotic lesions and intimal macrophages using CD36-targeted nanovesicles.

    Science.gov (United States)

    Nie, Shufang; Zhang, Jia; Martinez-Zaguilan, Raul; Sennoune, Souad; Hossen, Md Nazir; Lichtenstein, Alice H; Cao, Jun; Meyerrose, Gary E; Paone, Ralph; Soontrapa, Suthipong; Fan, Zhaoyang; Wang, Shu

    2015-12-28

    Current approaches to the diagnosis and therapy of atherosclerosis cannot target lesion-determinant cells in the artery wall. Intimal macrophage infiltration promotes atherosclerotic lesion development by facilitating the accumulation of oxidized low-density lipoproteins (oxLDL) and increasing inflammatory responses. The presence of these cells is positively associated with lesion progression, severity and destabilization. Hence, they are an important diagnostic and therapeutic target. The objective of this study was to noninvasively assess the distribution and accumulation of intimal macrophages using CD36-targeted nanovesicles. Soy phosphatidylcholine was used to synthesize liposome-like nanovesicles. 1-(Palmitoyl)-2-(5-keto-6-octene-dioyl) phosphatidylcholine was incorporated on their surface to target the CD36 receptor. All in vitro data demonstrate that these targeted nanovesicles had a high binding affinity for the oxLDL binding site of the CD36 receptor and participated in CD36-mediated recognition and uptake of nanovesicles by macrophages. Intravenous administration into LDL receptor null mice of targeted compared to non-targeted nanovesicles resulted in higher uptake in aortic lesions. The nanovesicles co-localized with macrophages and their CD36 receptors in aortic lesions. This molecular target approach may facilitate the in vivo noninvasive imaging of atherosclerotic lesions in terms of intimal macrophage accumulation and distribution and disclose lesion features related to inflammation and possibly vulnerability thereby facilitate early lesion detection and targeted delivery of therapeutic compounds to intimal macrophages. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Clustering and Candidate Motif Detection in Exosomal miRNAs by Application of Machine Learning Algorithms.

    Science.gov (United States)

    Gaur, Pallavi; Chaturvedi, Anoop

    2017-07-22

    The clustering pattern and motifs give immense information about any biological data. An application of machine learning algorithms for clustering and candidate motif detection in miRNAs derived from exosomes is depicted in this paper. Recent progress in the field of exosome research and more particularly regarding exosomal miRNAs has led much bioinformatic-based research to come into existence. The information on clustering pattern and candidate motifs in miRNAs of exosomal origin would help in analyzing existing, as well as newly discovered miRNAs within exosomes. Along with obtaining clustering pattern and candidate motifs in exosomal miRNAs, this work also elaborates the usefulness of the machine learning algorithms that can be efficiently used and executed on various programming languages/platforms. Data were clustered and sequence candidate motifs were detected successfully. The results were compared and validated with some available web tools such as 'BLASTN' and 'MEME suite'. The machine learning algorithms for aforementioned objectives were applied successfully. This work elaborated utility of machine learning algorithms and language platforms to achieve the tasks of clustering and candidate motif detection in exosomal miRNAs. With the information on mentioned objectives, deeper insight would be gained for analyses of newly discovered miRNAs in exosomes which are considered to be circulating biomarkers. In addition, the execution of machine learning algorithms on various language platforms gives more flexibility to users to try multiple iterations according to their requirements. This approach can be applied to other biological data-mining tasks as well.

  7. The method for detecting small lesions in medical image based on sliding window

    Science.gov (United States)

    Han, Guilai; Jiao, Yuan

    2016-10-01

    At present, the research on computer-aided diagnosis includes the sample image segmentation, extracting visual features, generating the classification model by learning, and according to the model generated to classify and judge the inspected images. However, this method has a large scale of calculation and speed is slow. And because medical images are usually low contrast, when the traditional image segmentation method is applied to the medical image, there is a complete failure. As soon as possible to find the region of interest, improve detection speed, this topic attempts to introduce the current popular visual attention model into small lesions detection. However, Itti model is mainly for natural images. But the effect is not ideal when it is used to medical images which usually are gray images. Especially in the early stages of some cancers, the focus of a disease in the whole image is not the most significant region and sometimes is very difficult to be found. But these lesions are prominent in the local areas. This paper proposes a visual attention mechanism based on sliding window, and use sliding window to calculate the significance of a local area. Combined with the characteristics of the lesion, select the features of gray, entropy, corner and edge to generate a saliency map. Then the significant region is segmented and distinguished. This method reduces the difficulty of image segmentation, and improves the detection accuracy of small lesions, and it has great significance to early discovery, early diagnosis and treatment of cancers.

  8. Revised PROPELLER for T2-weighted imaging of the prostate at 3 Tesla: impact on lesion detection and PI-RADS classification

    International Nuclear Information System (INIS)

    Meier-Schroers, Michael; Marx, Christian; Schmeel, Frederic Carsten; Wolter, Karsten; Block, Wolfgang; Sprinkart, Alois Martin; Traeber, Frank; Schild, Hans Heinz; Kukuk, Guido Matthias; Gieseke, Juergen; Willinek, Winfried

    2018-01-01

    To evaluate revised PROPELLER (RevPROP) for T2-weighted imaging (T2WI) of the prostate as a substitute for turbo spin echo (TSE). Three-Tesla MR images of 50 patients with 55 cancer-suspicious lesions were prospectively evaluated. Findings were correlated with histopathology after MRI-guided biopsy. T2 RevPROP, T2 TSE, diffusion-weighted imaging, dynamic contrast enhancement, and MR-spectroscopy were acquired. RevPROP was compared to TSE concerning PI-RADS scores, lesion size, lesion signal-intensity, lesion contrast, artefacts, and image quality. There were 41 carcinomas in 55 cancer-suspicious lesions. RevPROP detected 41 of 41 carcinomas (100%) and 54 of 55 lesions (98.2%). TSE detected 39 of 41 carcinomas (95.1%) and 51 of 55 lesions (92.7%). RevPROP showed fewer artefacts and higher image quality (each p < 0.001). No differences were observed between single and overall PI-RADS scores based on RevPROP or TSE (p = 0.106 and p = 0.107). Lesion size was not different (p = 0.105). T2-signal intensity of lesions was higher and T2-contrast of lesions was lower on RevPROP (each p < 0.001). For prostate cancer detection RevPROP is superior to TSE with respect to motion robustness, image quality and detection rates of lesions. Therefore, RevPROP might be used as a substitute for T2WI. (orig.)

  9. Revised PROPELLER for T2-weighted imaging of the prostate at 3 Tesla: impact on lesion detection and PI-RADS classification

    Energy Technology Data Exchange (ETDEWEB)

    Meier-Schroers, Michael; Marx, Christian; Schmeel, Frederic Carsten; Wolter, Karsten; Block, Wolfgang; Sprinkart, Alois Martin; Traeber, Frank; Schild, Hans Heinz; Kukuk, Guido Matthias [University Hospital Bonn, Department of Radiology, Bonn (Germany); Gieseke, Juergen [Philips Healthcare Germany, Hamburg (Germany); Willinek, Winfried [Hospital of Barmherzige Brueder, Department of Radiology, Neuroradiology, Sonography and Nuclear Medicine, Trier (Germany)

    2018-01-15

    To evaluate revised PROPELLER (RevPROP) for T2-weighted imaging (T2WI) of the prostate as a substitute for turbo spin echo (TSE). Three-Tesla MR images of 50 patients with 55 cancer-suspicious lesions were prospectively evaluated. Findings were correlated with histopathology after MRI-guided biopsy. T2 RevPROP, T2 TSE, diffusion-weighted imaging, dynamic contrast enhancement, and MR-spectroscopy were acquired. RevPROP was compared to TSE concerning PI-RADS scores, lesion size, lesion signal-intensity, lesion contrast, artefacts, and image quality. There were 41 carcinomas in 55 cancer-suspicious lesions. RevPROP detected 41 of 41 carcinomas (100%) and 54 of 55 lesions (98.2%). TSE detected 39 of 41 carcinomas (95.1%) and 51 of 55 lesions (92.7%). RevPROP showed fewer artefacts and higher image quality (each p < 0.001). No differences were observed between single and overall PI-RADS scores based on RevPROP or TSE (p = 0.106 and p = 0.107). Lesion size was not different (p = 0.105). T2-signal intensity of lesions was higher and T2-contrast of lesions was lower on RevPROP (each p < 0.001). For prostate cancer detection RevPROP is superior to TSE with respect to motion robustness, image quality and detection rates of lesions. Therefore, RevPROP might be used as a substitute for T2WI. (orig.)

  10. The role of second-look ultrasound of BIRADS-3 mammary lesions detected by breast MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fiaschetti, V., E-mail: fiaschettivaleria@tin.it [Department of Imaging Diagnostic, Molecular Imaging, Interventional Radiology and Radiation Therapy University Hospital ' Tor Vergata' , 81 Oxford street, 00133 Rome (Italy); Salimbeni, C.; Gaspari, E.; Dembele, G. Kabunda; Bolacchi, F.; Cossu, E.; Pistolese, C.A.; Perretta, T.; Simonetti, G. [Department of Imaging Diagnostic, Molecular Imaging, Interventional Radiology and Radiation Therapy University Hospital ' Tor Vergata' , 81 Oxford street, 00133 Rome (Italy)

    2012-11-15

    Objective: To asses the value of second-look ultrasound (US) for identifying BIRADS 3 (Breast Imaging Reporting Data System) mammary lesions detected by breast Magnetic Resonance imaging (MRI). Materials and methods: From April 2008 to May 2009 330 breast MRI were performed of which 60 patients are classified as BIRADS 3. 84 lesions underwent second-look US and percutaneous vacuum biopsy Vacora system US-guided. Statistical analysis: lesions were stratified into two groups: visible on US (Group 1) and not visible on US (Group 2). The clinical impact of second-look US was studied in terms of negative predictive value (NPV). Results: The positive predictive value (PPV) of category 3 BIRADS MRI was found to be 89%. Second look-US results detected lesions in 51% of the MRI enhancing lesions. The second look-US showed a NPV of 97%. The NPV of second look-US was significantly greater than the NPV of MRI BIRADS 3 (97% vs 89%, p < 0.05). The logistic regression analysis showed a higher number of malignant lesions in group 1 than in group 2 (7vs 2, OR 3.7, p < 0.05). Conclusions: The second-look US permitted the correct management of subcentimetric MRI BIRADS 3 lesions not visible with conventional imaging tecniques.

  11. The role of second-look ultrasound of BIRADS-3 mammary lesions detected by breast MR imaging

    International Nuclear Information System (INIS)

    Fiaschetti, V.; Salimbeni, C.; Gaspari, E.; Dembele, G. Kabunda; Bolacchi, F.; Cossu, E.; Pistolese, C.A.; Perretta, T.; Simonetti, G.

    2012-01-01

    Objective: To asses the value of second-look ultrasound (US) for identifying BIRADS 3 (Breast Imaging Reporting Data System) mammary lesions detected by breast Magnetic Resonance imaging (MRI). Materials and methods: From April 2008 to May 2009 330 breast MRI were performed of which 60 patients are classified as BIRADS 3. 84 lesions underwent second-look US and percutaneous vacuum biopsy Vacora system US-guided. Statistical analysis: lesions were stratified into two groups: visible on US (Group 1) and not visible on US (Group 2). The clinical impact of second-look US was studied in terms of negative predictive value (NPV). Results: The positive predictive value (PPV) of category 3 BIRADS MRI was found to be 89%. Second look-US results detected lesions in 51% of the MRI enhancing lesions. The second look-US showed a NPV of 97%. The NPV of second look-US was significantly greater than the NPV of MRI BIRADS 3 (97% vs 89%, p < 0.05). The logistic regression analysis showed a higher number of malignant lesions in group 1 than in group 2 (7vs 2, OR 3.7, p < 0.05). Conclusions: The second-look US permitted the correct management of subcentimetric MRI BIRADS 3 lesions not visible with conventional imaging tecniques.

  12. Simultaneous Whole-Brain Segmentation and White Matter Lesion Detection Using Contrast-Adaptive Probabilistic Models

    DEFF Research Database (Denmark)

    Puonti, Oula; Van Leemput, Koen

    2016-01-01

    In this paper we propose a new generative model for simultaneous brain parcellation and white matter lesion segmentation from multi-contrast magnetic resonance images. The method combines an existing whole-brain segmentation technique with a novel spatial lesion model based on a convolutional...... restricted Boltzmann machine. Unlike current state-of-the-art lesion detection techniques based on discriminative modeling, the proposed method is not tuned to one specific scanner or imaging protocol, and simultaneously segments dozens of neuroanatomical structures. Experiments on a public benchmark dataset...... in multiple sclerosis indicate that the method’s lesion segmentation accuracy compares well to that of the current state-of-the-art in the field, while additionally providing robust whole-brain segmentations....

  13. Assessment of the breath motion correction on the detectability of lesions in PET oncology

    International Nuclear Information System (INIS)

    Marache-Francisco, S.

    2012-02-01

    Positron emission tomography (PET) is a nuclear medicine imaging technique that produces a three-dimensional image of functional processes in the body. The system detects pairs of gamma rays emitted by a tracer, which is introduced into the body. Three-dimensional images of tracer concentration within the body are then constructed by computer analysis. Respiratory motion in emission tomography leads to image blurring especially in the lower thorax and the upper abdomen, influencing this way the quantitative accuracy of PET measurements as well as leading to a loss of sensitivity in lesion detection. Although PET exams are getting shorter thanks to the improvement of scanner sensitivity, the current 2-3 minutes acquisitions per bed position are not yet compatible with patient breath-holding. Performing accurate respiratory motion correction without impairing the standard clinical protocol, i.e. without increasing the acquisition time, thus remains challenging. Different types of respiratory motion correction approaches have been proposed, mostly based on the use of non-rigid deformation fields either applied to the gated PET images or integrated during an iterative reconstruction algorithm. Evaluation of theses methods has been mainly focusing on the quantification and localization accuracy of small lesions, but their impact on the clinician detection performance during the diagnostic task has not been fully investigated yet. The purpose of this study is to address this question based on a computer assisted detection study. We evaluate the influence of two motion correction methods on the detection of small lesions in human oncology FDG PET images. This study is based on a series of realistic simulated whole-body FDG images based on the XCAT model. Detection performance is evaluated with a computer-aided detection system that we are developing for whole-body PET/CT images. Detection performances achieved with these two correction methods are compared with those

  14. Accuracy of the detection of infratentorial stroke lesions using perfusion CT: an experimenter-blinded study

    Energy Technology Data Exchange (ETDEWEB)

    Lee, In Hyouk; Kim, Myung Soon; Kim, Young Ju; Lee, Myeong Sub [Yonsei University, Department of Radiology, Wonju College of Medicine, Wonju (Korea, Republic of); You, Joshua H. [Center for Health, Wellness, Fitness, Prevention, and Healing Across the Life Span, Department of Physical Therapy, Graduate School of Rehabilitation Science, Yonsei University, Center for Movement Impairment Solutions, Wonju City (Korea, Republic of); Lee, Ji Yong [Yonsei University, Department of Neurology, Wonju College of Medicine, Wonju (Korea, Republic of); Whang, Kum [Yonsei University, Department of Neurosurgery, Wonju College of Medicine, Wonju (Korea, Republic of)

    2010-12-15

    Although perfusion CT (PCT) for the detection of supratentorial stroke is well established, there is a dearth of evidence of its effectiveness in the detection of infratentorial stroke. Hence, this study compared sensitivity, specificity, and accuracy of PCT maps between infratentorial and supratentorial stroke lesions. One hundred patients with acute stroke who had successfully undergone near whole-brain PCT with the toggling table technique and follow-up MRI were included. Wilcoxon Mann-Whitney test was performed at P < 0.01. There was no significant statistical difference in the accuracy (91.79% vs. 93.23% in regional cerebral blood volume; 92.26% vs. 95.31% in regional cerebral blood flow; 89.17% vs. 92.71% in mean transit time; 89.76% vs. 92.19% in time to peak; P > 0.01 in all PCT maps) between supratentorial and infratentorial stroke. Also, there was no remarkable difference in both sensitivity and specificity of PCT maps. This was the first study to investigate the accuracy of PCT with the toggling table technique in detection of infratentorial stroke lesions. Clinically, PCT is highly reliable and accurate in detecting infratentorial stroke lesions. (orig.)

  15. Diagnostic performance of direct traction MR arthrography of the hip: detection of chondral and labral lesions with arthroscopic comparison

    International Nuclear Information System (INIS)

    Schmaranzer, Florian; Klauser, Andrea; Henninger, Benjamin; Kogler, Michael; Schmaranzer, Ehrenfried; Forstner, Thomas; Reichkendler, Markus

    2015-01-01

    To assess diagnostic performance of traction MR arthrography of the hip in detection and grading of chondral and labral lesions with arthroscopic comparison. Seventy-five MR arthrograms obtained ± traction of 73 consecutive patients (mean age, 34.5 years; range, 14-54 years) who underwent arthroscopy were included. Traction technique included weight-adapted traction (15-23 kg), a supporting plate for the contralateral leg, and intra-articular injection of 18-27 ml (local anaesthetic and contrast agent). Patients reported on neuropraxia and on pain. Two blinded readers independently assessed femoroacetabular cartilage and labrum lesions which were correlated with arthroscopy. Interobserver agreement was calculated using κ values. Joint distraction ± traction was evaluated in consensus. No procedure had to be stopped. There were no cases of neuropraxia. Accuracy for detection of labral lesions was 92 %/93 %, 91 %/83 % for acetabular lesions, and 92 %/88 % for femoral cartilage lesions for reader 1/reader 2, respectively. Interobserver agreement was moderate (κ = 0.58) for grading of labrum lesions and substantial (κ = 0.7, κ = 0.68) for grading of acetabular and femoral cartilage lesions. Joint distraction was achieved in 72/75 and 14/75 hips with/without traction, respectively. Traction MR arthrography safely enabled accurate detection and grading of labral and chondral lesions. (orig.)

  16. Diagnostic performance of direct traction MR arthrography of the hip: detection of chondral and labral lesions with arthroscopic comparison

    Energy Technology Data Exchange (ETDEWEB)

    Schmaranzer, Florian; Klauser, Andrea; Henninger, Benjamin [Medical University Innsbruck, Department of Radiology, Innsbruck (Austria); Kogler, Michael; Schmaranzer, Ehrenfried [District Hospital St. Johann in Tyrol, Department of Radiology, St. Johann in Tyrol (Austria); Forstner, Thomas [Johannes Keppler University, Department for Applied Systems Research and Statistics, Linz (Austria); Reichkendler, Markus [District Hospital St. Johann in Tyrol, Department of Orthopedic Surgery, St. Johann in Tyrol (Austria)

    2015-06-01

    To assess diagnostic performance of traction MR arthrography of the hip in detection and grading of chondral and labral lesions with arthroscopic comparison. Seventy-five MR arthrograms obtained ± traction of 73 consecutive patients (mean age, 34.5 years; range, 14-54 years) who underwent arthroscopy were included. Traction technique included weight-adapted traction (15-23 kg), a supporting plate for the contralateral leg, and intra-articular injection of 18-27 ml (local anaesthetic and contrast agent). Patients reported on neuropraxia and on pain. Two blinded readers independently assessed femoroacetabular cartilage and labrum lesions which were correlated with arthroscopy. Interobserver agreement was calculated using κ values. Joint distraction ± traction was evaluated in consensus. No procedure had to be stopped. There were no cases of neuropraxia. Accuracy for detection of labral lesions was 92 %/93 %, 91 %/83 % for acetabular lesions, and 92 %/88 % for femoral cartilage lesions for reader 1/reader 2, respectively. Interobserver agreement was moderate (κ = 0.58) for grading of labrum lesions and substantial (κ = 0.7, κ = 0.68) for grading of acetabular and femoral cartilage lesions. Joint distraction was achieved in 72/75 and 14/75 hips with/without traction, respectively. Traction MR arthrography safely enabled accurate detection and grading of labral and chondral lesions. (orig.)

  17. Diagnostic Accuracy and Inter-Observer Agreement of Shoulder Magnetic Resonance Arthrography in the Detection of Labral Lesion and Assessment of Lesion Location

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Young; Song, Sook Yun; Choi, Jin Ha; Shin, Sang Jin [School of Medicine, Ewha Womans University, Mokdong Hospital, Seoul (Korea, Republic of)

    2012-11-15

    To evaluate the diagnostic accuracy and inter-observer agreement of magnetic resonance (MR) arthrography in the detection of labral lesions by location and to describe useful MR imaging findings of labral tears. Sixty-eight patients who underwent both pre-operative MR arthrography and arthroscopy were included. The location of the labrum was classified into anterior (2-6 o'clock), superior (12-2 o'clock), and posterior (6-12 o'clock). Sensitivity, specificity, accuracy, and inter-observer agreement of MR arthrography for the diagnosis of labral lesions by location were calculated. Frequency of MR imaging findings such as detachment, high signal intensity cleft, contour change, absence, and signal change of the labrum by location were analyzed. 35 anterior, 44 superior and 15 posterior labral lesions were detected by arthroscopy. The corresponding sensitivities were 91.4%, 79.5%, and 40.0%, specificities were 90.9%, 20.8%, and 86.8%, accuracies were 91.2%, 58.8%, and 76.5%, and kappa values were 0.823, 0.252, and 0.394, for anterior, superior, posterior lesions, respectively. The most common MR imaging findings were detachment in 60.0% of anterior labrums, high signal intensity cleft in 52.3% of superior labrums, and normal in 60.0% of posterior labrums. Diagnostic accuracy and inter-observer agreement of MR arthrography in the diagnosis of labral lesions are high in anterior labrums and low in superior or posterior labrums. The useful MR imaging findings of labral tears were different according to labral location.

  18. Comparison between immediate and delayed imaging after gadolinium chelate injection for detecting enhanced lesions in multiple sclerosis

    International Nuclear Information System (INIS)

    Alizadeh, A.; Roudbari, A.; Heidarzadeh, A.; Kouhsari, M.

    2010-01-01

    Magnetic resonance imaging is a noninvasive and valuable method in the diagnosis of Multiple Sclerosis. Compared with other modalities, the sensitivity of Magnetic resonance imaging for detection of the lesion increases using magnetization transfer and delayed imaging. Our aim was to compare the two methods in detecting Multiple Sclerosis lesions. Patients and Methods: In this double-blind clinical trial, twenty-one patients with the definite diagnosis of Multiple Sclerosis referred to Poursina Hospital, Rasht were included. Two radiologists evaluated all the images. First, images without contrast were conducted, then 0.1 mmol/kg contrast material (Dotarem, single dose) was injected and after 30 minutes, T1W and magnetization transfer images were obtained. Seventy-two hours later, T1W images were obtained immediately after injection of 0.2 mmol/kg contrast material (double dose). The data were analyzed using Fisher's and McNemar tests by SPSS for Windows. Results: Delayed magnetization transfer showed 44 enhanced lesions using magnetization transfer (69.84%) and 29 lesions using T1 (46.03%). In addition, the number of enhanced lesions in the delayed method were significantly more than those in the immediate method (p value=0.003). Conclusion: The use of single dose in combination with magnetization transfer and delayed images after 20-30 minutes enables us to detect more enhanced lesions.

  19. Time-resolved optical mammography between 637 and 985 nm: clinical study on the detection and identification of breast lesions

    International Nuclear Information System (INIS)

    Taroni, Paola; Torricelli, Alessandro; Spinelli, Lorenzo; Pifferi, Antonio; Arpaia, Francesco; Danesini, Gianmaria; Cubeddu, Rinaldo

    2005-01-01

    The first time-resolved optical mammograph operating beyond 900 nm was tested in a retrospective clinical study involving 194 patients with malignant and benign lesions, to investigate the diagnostic potential for the detection and characterization of breast lesions. For the first part of the study (101 patients with 114 lesions), the system was operated at 683, 785, 913 and 975 nm. Subsequently, to improve the spectral content of optical images, the number of wavelengths was increased (up to 7) and the spectral range was extended (637-985 nm). Late gated intensity and scattering images provide sensitivity to tissue composition (oxy- and deoxyhaemoglobin, water and lipids) and physiology (total haemoglobin content and oxygen saturation), as well as to structural changes. Tumours are typically identified because of the strong blood absorption at short wavelengths (637-685 nm), while cysts are characterized by low scattering, leading to a detection rate of approximately 80% for both lesion types, when detection is required in both cranio-caudal and oblique views. The detection rate for other benign lesions, such as fibroadenomas, is presently much lower (<40%). The effectiveness of the technique in localizing and identifying different lesion types was analysed as a function of various parameters (lesion size, compressed breast thickness, age, body mass index, breast parenchymal pattern). The possibility that physiologic changes due to the development of a malignant lesion could affect the entire breast was investigated. The capacity to assess the density of breast based on the average scattering properties was also tested

  20. Molecular detection of Leptospira spp. from canine kidney tissues and its association with renal lesions

    Directory of Open Access Journals (Sweden)

    Biswajit R. Dash

    2018-04-01

    Full Text Available Aim: The study aimed to detect the prevalence of Leptospira spp. in kidney tissues collected during necropsy and to establish its association with renal lesions in dogs of Mumbai region. Materials and Methods: Kidney tissues from 40 dogs were collected during necropsy after gross examination and then fixed in neutral buffered formalin and Bouin's fluid for histopathology and histochemistry, respectively. Kidney tissues were also collected for the detection of Leptospira spp. by polymerase chain reaction (PCR in a sterile container and stored at -80°C until further processing. Results: Of 40 cases studied, 13 (32.5% cases showed lesions of nephritis of varying histotype and severity. Glomerulonephritis was reported as the most common type of nephritis in 9 (69.23% cases, and interstitial nephritis was recorded in 4 (30.76% cases. Chronic and acute interstitial nephritis was observed in two cases each. Renal failure as a cause of death was found in 7 (17.5% dogs. Of a total of 40 cases, 9 were found positive for pathogenic Leptospira spp. genome by PCR. However, of nine PCR-positive cases, only four cases showed lesions in kidneys as glomerulonephritis and interstitial nephritis in two cases each. The rest five cases positive for Leptospira spp. by PCR did not show any appreciable lesions in the kidneys. Conclusion: Leptospiral DNA was detected in 9 (22.5% cases by PCR. Of these nine cases, only four cases showed renal lesions. Other five cases which were positive for Leptospira spp. by PCR did not show any appreciable gross and microscopic lesions in the kidneys which might be carriers for Leptospira spp. Considering variable reports on types of nephritis in Leptospira spp. infection and also the prevalence of non-pathogenic Leptospira spp., it is important to conduct an extensive study on the prevalence of Leptospira spp. and its association with renal lesions involving batteries of tests.

  1. Computer-aided detection (CAD) and assessment of malignant lesions in the liver and lung using a novel PET/CT software tool. Initial results

    International Nuclear Information System (INIS)

    Hahn, Steffen; Heusner, T.; Forsting, M.; Antoch, G.; Zhou, X.; Zhan, Y.; Peng, Z.; Hamami, M.; Bockisch, A.

    2010-01-01

    Purpose: To determine the feasibility of a PET/CT software tool (PET computer-aided detection: PET-CAD) for automated detection and assessment of pulmonary and hepatic lesions. Materials and Methods: 20 consecutive patients with colorectal liver metastases and 20 consecutive patients suffering from non-small cell lung cancer (NSCLC) were examined with FDG-PET/CT. In a first step the maximum standardized uptake values (SUV max ) of non-tumorous liver and lung tissues were determined manually. This value was used as a threshold value for software-based lesion detection. The number of lesions detected, their SUV max , and their sizes in the x, y, and z-planes, as automatically provided by PET-CAD, were compared to visual lesion detection and manual measurements on CT. Results: The sensitivity for automated detection was 96% (86-99%) for colorectal liver metastases and 90% (70-99%) for lung lesions. The positive predictive value was 80% for liver and 68% for lung lesions. The mean SUV max of all lung lesions was 9.3 and 8.8 for the liver lesions. When assessed by PET-CAD, the mean lesion sizes for liver lesions in the x, y, and z-planes were 4.3 cm, 4.6 cm, and 4.2 cm compared to 3.5 cm, 3.8 cm, and 3.6 cm for manual measurements. The mean lesion sizes of lung lesions were 7.4 cm, 7.7 cm, and 8.4 cm in the x, y, and z-planes when assessed by PET-CAD compared to 5.8 cm, 6.1 cm, and 7.1 cm when measured manually. Using manual assessment, the lesion sizes were significantly smaller in all planes (p < 0.005). Conclusion: Software tools for automated lesion detection and assessment are expected to improve the clinical PET/CT workflow. Before implementation in the clinical routine, further improvements to the measurement accuracy are required. (orig.)

  2. Diffusion-weighted imaging as part of hybrid PET/MRI protocols for whole-body cancer staging: Does it benefit lesion detection?

    Energy Technology Data Exchange (ETDEWEB)

    Buchbender, Christian, E-mail: christian.buchbender@med.uni-duesseldorf.de [Univ Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Moorenstr. 5, D-40225 Dusseldorf (Germany); Hartung-Knemeyer, Verena, E-mail: verena.hartung@uk-essen.de [Univ Duisburg-Essen, Medical Faculty, Department of Nuclear Medicine, Hufelandstr. 55, D-45147 Essen (Germany); Beiderwellen, Karsten, E-mail: karsten.beiderwellen@uk-essen.de [Univ Duisburg-Essen, Medical Faculty, Department of Diagnostic and Interventional Radiology and Neuroradiology, Hufelandstr. 55, D-45147 Essen (Germany); Heusch, Philipp, E-mail: philipp.heusch@med.uni-duesseldorf.de [Univ Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Moorenstr. 5, D-40225 Dusseldorf (Germany); Kühl, Hilmar, E-mail: hilmar.kuehl@uni-due.de [Univ Duisburg-Essen, Medical Faculty, Department of Diagnostic and Interventional Radiology and Neuroradiology, Hufelandstr. 55, D-45147 Essen (Germany); Lauenstein, Thomas C., E-mail: thomas.lauenstein@uk-essen.de [Univ Duisburg-Essen, Medical Faculty, Department of Diagnostic and Interventional Radiology and Neuroradiology, Hufelandstr. 55, D-45147 Essen (Germany); Forsting, Michael, E-mail: michael.forsting@uk-essen.de [Univ Duisburg-Essen, Medical Faculty, Department of Diagnostic and Interventional Radiology and Neuroradiology, Hufelandstr. 55, D-45147 Essen (Germany); Antoch, Gerald, E-mail: antoch@med.uni-duesseldorf.de [Univ Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Moorenstr. 5, D-40225 Dusseldorf (Germany); Heusner, Till A., E-mail: heusner@med.uni-duesseldorf.de [Univ Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Moorenstr. 5, D-40225 Dusseldorf (Germany)

    2013-05-15

    Purpose: Positron emission tomography/magnetic resonance imaging (PET/MRI) requires efficient scan protocols for whole-body cancer staging. The aim of this study was to evaluate if the application of diffusion-weighted MR imaging (DWI) results in a diagnostic benefit for lesion detection in oncologic patients if added to a whole-body [18F]-fluorodesoxyglucose ([18F]-FDG) PET/MRI protocol. Methods: 25 consecutive oncologic patients (16 men, 9 women; age 57 ± 12 years) prospectively underwent whole-body [18F]-FDG-PET/MRI including DWI on a hybrid PET/MRI scanner. A team of two readers assessed [18F]-FDG PET/MRI without DWI for primary tumors and metastases. In a second session, now considering DWI, readers reassessed [18F]-FDG PET/MRI accordingly. Additionally, the lesion-to-background contrast on [18F]-FDG PET and DWI was rated qualitatively (0, invisible; 1, low; 2, intermediate; 3, high). Wilcoxon's signed-rank test was performed to test for differences in the lesion-to-background contrast. Results: 49 lesions were detected in 16 patients (5 primaries, 44 metastases). All 49 lesions were concordantly detected by [18F]-FDG PET/MRI alone and [18F]-FDG PET/MRI with DWI. The lesion-to-background contrast on DWI compared to [18F]-FDG PET was rated lower in 22 (44.9%) of 49 detected lesions resulting in a significantly higher lesion-to-background contrast on [18F]-FDG PET compared to DWI (P = 0.001). Conclusions: DWI as part of whole-body [18F]-FDG PET/MRI does not benefit lesion detection. Given the necessity to optimize imaging protocols with regard to patient comfort and efficacy, DWI has to be questioned as a standard tool for whole-body staging in oncologic PET/MRI.

  3. PET-CT detection rate of primary breast cancer lesions. Correlation with the clinicopathological factors

    International Nuclear Information System (INIS)

    Ogawa, Tomoko; Tozaki, Mitsuhiro; Fukuma, Eisuke

    2008-01-01

    One hundred and forty lesions of primary breast cancer underwent positron emission tomography (PET)-CT between June 2006 and May 2007. The PET-CT detection rate of primary breast cancer lesions was 72.1%. The detection rate was 52.1% for invasive cancer ≤20 mm, 92.8% for invasive breast cancers >20 mm, and these results were significant. In the present study, no significant relationship was observed between tumor types, however, invasive lobular carcinoma showed a lower detection rate, 58.3%. The PET-CT results were not significantly affected by either estrogen and progesterone receptors or distant metastasis. A significant correlation regarding the detection rate of PET-CT was found with HER2 status, tumor grade, and axillary lymph node status. The detection rate was 100% for invasive cancer ≤20 mm when the interval between prior diagnostic Mammotome biopsies and PET-CT was less than 3 weeks, 18.8% for invasive cancer ≤20 mm when the interval was more than 3 weeks, and these results were significant. Mammotome biopsies may therefore affect the detection rate of PET-CT. Invasive cancers ≤20 mm showed a low detection rate, therefore, it is considered to be insufficient to use PET-CT for the detection of early breast cancer. (author)

  4. Dark Galaxy Candidates at Redshift ∼3.5 Detected with MUSE

    Science.gov (United States)

    Marino, Raffaella Anna; Cantalupo, Sebastiano; Lilly, Simon J.; Gallego, Sofia G.; Straka, Lorrie A.; Borisova, Elena; Pezzulli, Gabriele; Bacon, Roland; Brinchmann, Jarle; Carollo, C. Marcella; Caruana, Joseph; Conseil, Simon; Contini, Thierry; Diener, Catrina; Finley, Hayley; Inami, Hanae; Leclercq, Floriane; Muzahid, Sowgat; Richard, Johan; Schaye, Joop; Wendt, Martin; Wisotzki, Lutz

    2018-05-01

    Recent theoretical models suggest that the early phase of galaxy formation could involve an epoch when galaxies are gas rich but inefficient at forming stars: a “dark galaxy” phase. Here, we report the results of our Multi-Unit Spectroscopic Explorer (MUSE) survey for dark galaxies fluorescently illuminated by quasars at z > 3. Compared to previous studies which are based on deep narrowband (NB) imaging, our integral field survey provides a nearly uniform sensitivity coverage over a large volume in redshift space around the quasars as well as full spectral information at each location. Thanks to these unique features, we are able to build control samples at large redshift distances from the quasars using the same data taken under the same conditions. By comparing the rest-frame equivalent width (EW0) distributions of the Lyα sources detected in proximity to the quasars and in control samples, we detect a clear correlation between the locations of high-EW0 objects and the quasars. This correlation is not seen in other properties, such as Lyα luminosities or volume overdensities, suggesting the possible fluorescent nature of at least some of these objects. Among these, we find six sources without continuum counterparts and EW0 limits larger than 240 Å that are the best candidates for dark galaxies in our survey at z > 3.5. The volume densities and properties, including inferred gas masses and star formation efficiencies, of these dark galaxy candidates are similar to those of previously detected candidates at z ≈ 2.4 in NB surveys. Moreover, if the most distant of these are fluorescently illuminated by the quasar, our results also provide a lower limit of t = 60 Myr on the quasar lifetime. Based on observations obtained at the Very Large Telescope (VLT) of the European Southern Observatory, Paranal, Chile (ESO Programme IDs 094.A-0396, 095.A-0708, 096.A-0345, 097.A-0251, 098.A-0678, 094.A-0131, 095.A-0200, 096.A-0222, 097.A-0089, 098.A-0216).

  5. The reliability of magnetic resonance imaging in traumatic brain injury lesion detection

    NARCIS (Netherlands)

    Geurts, B.H.J.; Andriessen, T.M.J.C.; Goraj, B.M.; Vos, P.E.

    2012-01-01

    Objective: This study compares inter-rater-reliability, lesion detection and clinical relevance of T2-weighted imaging (T2WI), Fluid Attenuated Inversion Recovery (FLAIR), T2*-gradient recalled echo (T2*-GRE) and Susceptibility Weighted Imaging (SWI) in Traumatic Brain Injury (TBI). Methods: Three

  6. Maximum likelihood fitting of FROC curves under an initial-detection-and-candidate-analysis model

    International Nuclear Information System (INIS)

    Edwards, Darrin C.; Kupinski, Matthew A.; Metz, Charles E.; Nishikawa, Robert M.

    2002-01-01

    We have developed a model for FROC curve fitting that relates the observer's FROC performance not to the ROC performance that would be obtained if the observer's responses were scored on a per image basis, but rather to a hypothesized ROC performance that the observer would obtain in the task of classifying a set of 'candidate detections' as positive or negative. We adopt the assumptions of the Bunch FROC model, namely that the observer's detections are all mutually independent, as well as assumptions qualitatively similar to, but different in nature from, those made by Chakraborty in his AFROC scoring methodology. Under the assumptions of our model, we show that the observer's FROC performance is a linearly scaled version of the candidate analysis ROC curve, where the scaling factors are just given by the FROC operating point coordinates for detecting initial candidates. Further, we show that the likelihood function of the model parameters given observational data takes on a simple form, and we develop a maximum likelihood method for fitting a FROC curve to this data. FROC and AFROC curves are produced for computer vision observer datasets and compared with the results of the AFROC scoring method. Although developed primarily with computer vision schemes in mind, we hope that the methodology presented here will prove worthy of further study in other applications as well

  7. Early detection of breast cancer mass lesions by mammogram segmentation images based on texture features

    International Nuclear Information System (INIS)

    Mahmood, F.H.

    2012-01-01

    Mammography is at present one of the available method for early detection of masses or abnormalities which is related to breast cancer.The calcifications. The challenge lies in early and accurate detection to overcome the development of breast cancer that affects more and more women throughout the world. Breast cancer is diagnosed at advanced stages with the help of the digital mammogram images. Masses appear in a mammogram as fine, granular clusters, which are often difficult to identify in a raw mammogram. The incidence of breast cancer in women has increased significantly in recent years. This paper proposes a computer aided diagnostic system for the extraction of features like mass lesions in mammograms for early detection of breast cancer. The proposed technique is based on a four-step procedure: (a) the preprocessing of the image is done, (b) regions of interest (ROI) specification, (c) supervised segmentation method includes two to stages performed using the minimum distance (M D) criterion, and (d) feature extraction based on Gray level Co-occurrence matrices GLC M for the identification of mass lesions. The method suggested for the detection of mass lesions from mammogram image segmentation and analysis was tested over several images taken from A L-llwiya Hospital in Baghdad, Iraq.The proposed technique shows better results.

  8. Detection of lesions in multiple sclerosis by 2D FLAIR and single-slab 3D FLAIR sequences at 3.0 T: initial results

    International Nuclear Information System (INIS)

    Bink, Andrea; Gaa, Jochen; Lanfermann, Heinrich; Zanella, Friedhelm E.; Schmitt, Melanie; Mugler, John P.

    2006-01-01

    The aim of this study was to compare conventional 2D FLAIR and single-slab 3D FLAIR sequences in the detection of lesions in patients with multiple sclerosis. Eight patients with MS were examined at 3.0 T by using a 2D FLAIR sequence and a single-slab 3D FLAIR sequence. A comparison of lesion detectability was performed for the following regions: periventricular, nonperiventricular/juxtacortical and infratentorial. The contrast-to-noise ratios (CNRs) between lesions and brain tissue and CSF were calculated for each sequence. A total of 424 lesions were found using the 2D FLAIR sequence, while with the 3D FLAIR sequence 719 lesions were found. With the 2D FLAIR sequence, 41% fewer lesions were detected than with the 3D FLAIR sequence. Further, 40% fewer supratentorial and 62.5% fewer infratentorial lesions were found with the 2D FLAIR sequence. In images acquired with the 3D FLAIR sequence, the lesions had significantly higher CNRs than in images acquired with the 2D FLAIR sequence. These are the first results using a single-slab 3D FLAIR sequence at 3.0 T for detection of lesions in patients with MS. With the 3D FLAIR sequence significantly higher CNRs were achieved and significantly more lesions in patients with MS were detected. (orig.)

  9. DETECTION OF A BIPOLAR MOLECULAR OUTFLOW DRIVEN BY A CANDIDATE FIRST HYDROSTATIC CORE

    International Nuclear Information System (INIS)

    Dunham, Michael M.; Chen Xuepeng; Arce, Héctor G.; Bourke, Tyler L.; Schnee, Scott; Enoch, Melissa L.

    2011-01-01

    We present new 230 GHz Submillimeter Array observations of the candidate first hydrostatic core Per-Bolo 58. We report the detection of a 1.3 mm continuum source and a bipolar molecular outflow, both centered on the position of the candidate first hydrostatic core. The continuum detection has a total flux density of 26.6 ± 4.0 mJy, from which we calculate a total (gas and dust) mass of 0.11 ± 0.05 M ☉ and a mean number density of 2.0 ± 1.6 × 10 7 cm –3 . There is some evidence for the existence of an unresolved component in the continuum detection, but longer-baseline observations are required in order to confirm the presence of this component and determine whether its origin lies in a circumstellar disk or in the dense inner envelope. The bipolar molecular outflow is observed along a nearly due east-west axis. The outflow is slow (characteristic velocity of 2.9 km s –1 ), shows a jet-like morphology (opening semi-angles ∼8° for both lobes), and extends to the edges of the primary beam. We calculate the kinematic and dynamic properties of the outflow in the standard manner and compare them to several other protostars and candidate first hydrostatic cores with similarly low luminosities. We discuss the evidence both in support of and against the possibility that Per-Bolo 58 is a first hydrostatic core, and we outline future work needed to further evaluate the evolutionary status of this object.

  10. Comparison of Digital Tomosynthesis and Chest Radiography for the Detection of Noncalcified Pulmonary and Hilar Lesions.

    Science.gov (United States)

    Galea, Angela; Adlan, Tarig; Gay, David; Roobottom, Carl; Dubbins, Paul; Riordan, Richard

    2015-09-01

    The aim of this study was to compare the sensitivity and specificity of chest digital tomosynthesis (DTS) with chest radiography (CXR) for the detection of noncalcified pulmonary nodules and hilar lesions using computed tomography (CT) as the reference standard. A total of 78 patients with suspected noncalcified pulmonary lesions on CXR were included in the study. Two radiologists, blinded to the history and CT, analyzed the CXR and the DTS images (separately), whereas a third radiologist analyzed the CXR and DTS images together. Noncalcified intrapulmonary nodules and hilar lesions were recorded for analysis. The interobserver agreement for CXR and DTS was assessed, and the time taken to report the images was recorded. A total of 202 lesions were recorded in 78 patients. There were 111 true lesions confirmed on CT in 53 patients; in 25 patients subsequent CT excluded a lesion. The overall sensitivity was 32% for CXR and 49% for DTS. This improved to 54% when the posteroanterior CXR and DTS were reviewed together (CXR-DTS). The overall specificities for CXR, DTS, and CXR-DTS were 49%, 96%, and 98%, respectively. There were 56 suspected hilar lesions with subgroup sensitivities of 76% for CXR, 65% for DTS, and 76% for CXR-DTS. The specificity for hilar lesions was 59%, 92%, and 97% for CXR, DTS, and CXR-DTS, respectively. DTS significantly improves the detectability of noncalcified nodules when compared with and when used in combination with CXR. The specificity and interobserver agreement of DTS in the diagnosis of suspected noncalcified pulmonary nodules and hilar lesions are significantly better than those of CXR and approaches those of CT.

  11. Automatic detection and recognition of multiple macular lesions in retinal optical coherence tomography images with multi-instance multilabel learning

    Science.gov (United States)

    Fang, Leyuan; Yang, Liumao; Li, Shutao; Rabbani, Hossein; Liu, Zhimin; Peng, Qinghua; Chen, Xiangdong

    2017-06-01

    Detection and recognition of macular lesions in optical coherence tomography (OCT) are very important for retinal diseases diagnosis and treatment. As one kind of retinal disease (e.g., diabetic retinopathy) may contain multiple lesions (e.g., edema, exudates, and microaneurysms) and eye patients may suffer from multiple retinal diseases, multiple lesions often coexist within one retinal image. Therefore, one single-lesion-based detector may not support the diagnosis of clinical eye diseases. To address this issue, we propose a multi-instance multilabel-based lesions recognition (MIML-LR) method for the simultaneous detection and recognition of multiple lesions. The proposed MIML-LR method consists of the following steps: (1) segment the regions of interest (ROIs) for different lesions, (2) compute descriptive instances (features) for each lesion region, (3) construct multilabel detectors, and (4) recognize each ROI with the detectors. The proposed MIML-LR method was tested on 823 clinically labeled OCT images with normal macular and macular with three common lesions: epiretinal membrane, edema, and drusen. For each input OCT image, our MIML-LR method can automatically identify the number of lesions and assign the class labels, achieving the average accuracy of 88.72% for the cases with multiple lesions, which better assists macular disease diagnosis and treatment.

  12. Impact of variations in fatty liver on sonographic detection of focal hepatic lesions originally identified by CT

    OpenAIRE

    Wu, Size; Tu, Rong; Nan, Ruixia; Liu, Guangqing; Cui, Xiaojing; Liang, Xian

    2015-01-01

    Purpose: The aim of this study was to investigate the influence of variations in fatty liver on the ultrasonographic detection of focal liver lesions. Methods: A total of 229 patients with varying degrees of fatty liver and focal liver lesions and 200 patients with focal liver lesions but no fatty liver were randomly selected for inclusion in groups I and II, respectively. Findings of focal liver lesions identified on computed tomography were taken as the reference, and findings on ultrasonog...

  13. Comparison of triple dose versus standard dose gadolinium-DTPA for detection of MRI enhancing lesions in patients with primary progressive multiple sclerosis.

    Science.gov (United States)

    Filippi, M; Campi, A; Martinelli, V; Colombo, B; Yousry, T; Canal, N; Scotti, G; Comi, G

    1995-01-01

    This study was performed to evaluate whether a triple dose of gadolinium-DTPA (Gd-DTPA) increases the sensitivity of brain MRI for detecting enhancing lesions in patients with primary progressive multiple sclerosis (PPMS). T1 weighted brain MRI was obtained for 10 patients with PPMS in two sessions. In the first session, one scan was obtained five to seven minutes after the injection of 0.1 mmol/kg Gd-DTPA (standard dose). In the second session, six to 24 hours later, one scan before and two scans five to seven minutes and one hour after the injection of 0.3 mmol/kg Gd-DTPA (triple dose) were obtained. Four enhancing lesions were detected in two patients when the standard dose of Gd-DTPA was used. The numbers of enhancing lesions increased to 13 and the numbers of patients with such lesions to five when the triple dose of Gd-DTPA was used and to 14 and six in the one hour delayed scans. The mean contrast ratio for enhancing lesions detected with the triple dose of Gd-DTPA was higher than those for lesions present in both the standard dose (P DTPA many more enhancing lesions can be detected in patients with PPMS. This is important both for planning clinical trials and for detecting the presence of inflammation in vivo in the lesions of such patients. Images PMID:8530944

  14. Can breast MRI computer-aided detection (CAD) improve radiologist accuracy for lesions detected at MRI screening and recommended for biopsy in a high-risk population?

    International Nuclear Information System (INIS)

    Arazi-Kleinman, T.; Causer, P.A.; Jong, R.A.; Hill, K.; Warner, E.

    2009-01-01

    Aim: To evaluate the sensitivity and specificity of magnetic resonance imaging (MRI) computer-aided detection (CAD) for breast MRI screen-detected lesions recommended for biopsy in a high-risk population. Material and methods: Fifty-six consecutive Breast Imaging Reporting and Data System (BI-RADS) 3-5 lesions with histopathological correlation [nine invasive cancers, 13 ductal carcinoma in situ (DCIS) and 34 benign] were retrospectively evaluated using a breast MRI CAD prototype (CAD-Gaea). CAD evaluation was performed separately and in consensus by two radiologists specializing in breast imaging, blinded to the histopathology. Thresholds of 50, 80, and 100% and delayed enhancement were independently assessed with CAD. Lesions were rated as malignant or benign according to threshold and delayed enhancement only and in combination. Sensitivities, specificities, and negative predictive values (NPV) were determined for CAD assessments versus pathology. Initial MRI BI-RADS interpretation without CAD versus CAD assessments were compared using paired binary diagnostic tests. Results: Threshold levels for lesion enhancement were: 50% to include all malignant (and all benign) lesions; and 100% for all invasive cancer and high-grade DCIS. Combined use of threshold and enhancement patterns for CAD assessment was best (73% sensitivity, 56% specificity and 76% NPV for all cancer). Sensitivities and NPV were better for invasive cancer (100%/100%) than for all malignancies (54%/76%). Radiologists' MRI interpretation was more sensitive than CAD (p = 0.05), but less specific (p = 0.001) for cancer detection. Conclusion: The breast MRI CAD system used could not improve the radiologists' accuracy for distinguishing all malignant from benign lesions, due to the poor sensitivity for DCIS detection.

  15. Descriptive data on cancerous lung lesions detected by auto-fluorescence bronchoscope: A five-year study

    Directory of Open Access Journals (Sweden)

    Asmitananda Thakur

    2012-01-01

    Full Text Available Background: Auto-fluorescence bronchoscopy (AFB has been used for the identification and localization of intra-epithelial pre-neoplastic and neoplastic lesions within the bronchus. Objectives: To determine the applicability of AFB for the detection and localization of precancerous and cancerous lesions, in addition to analyzing the morphologic presentation, their association to histological type and the variation between genders. Methods: A five-year study involving 4983 patients, who underwent routine bronchoscopy [B] examination in a local tertiary teaching hospital, was done. The B examination was performed under intratracheal lidocaine, and samples were obtained using suitable approach. One thousand four hundred and eighty-five pathologically confirmed lung cancer patients were included in the study. The following parameters were studied: Morphological presentation, biopsy sites, histology. Differences between the groups were analyzed using Chi square test. Result: One thousand four hundred and eighty-five patients who had hyperplasia or neoplastic lesions were further confirmed as lung cancer pathologically. Lung cancer was more commonly found in the right lung (51.58% vs. 42.82%. The lesion occurred more frequently in the upper lobe than the lower lobe (44.17% vs. 22.42%. Male patients with squamous cell carcinoma showed upper lobe involvement more commonly, while the left main bronchus was more commonly involved in female patients. Adenocarcinoma mostly involved lesion of the upper lobe. Squamous cell carcinoma and small cell carcinoma were the major proliferative types (80.15% and 76.16% respectively. Conclusion: AFB is efficient in the detection of pre-invasive and invasive lung lesions. The morphological presentation is associated to the histological type. There is variation in the presentation and histology of cancerous lung lesions between genders.

  16. Detection of small human cerebral cortical lesions with MRI under different levels of Gaussian smoothing: applications in epilepsy

    Science.gov (United States)

    Cantor-Rivera, Diego; Goubran, Maged; Kraguljac, Alan; Bartha, Robert; Peters, Terry

    2010-03-01

    The main objective of this study was to assess the effect of smoothing filter selection in Voxel-Based Morphometry studies on structural T1-weighted magnetic resonance images. Gaussian filters of 4 mm, 8 mm or 10 mm Full Width at High Maximum are commonly used, based on the assumption that the filter size should be at least twice the voxel size to obtain robust statistical results. The hypothesis of the presented work was that the selection of the smoothing filter influenced the detectability of small lesions in the brain. Mesial Temporal Sclerosis associated to Epilepsy was used as the case to demonstrate this effect. Twenty T1-weighted MRIs from the BrainWeb database were selected. A small phantom lesion was placed in the amygdala, hippocampus, or parahippocampal gyrus of ten of the images. Subsequently the images were registered to the ICBM/MNI space. After grey matter segmentation, a T-test was carried out to compare each image containing a phantom lesion with the rest of the images in the set. For each lesion the T-test was repeated with different Gaussian filter sizes. Voxel-Based Morphometry detected some of the phantom lesions. Of the three parameters considered: location,size, and intensity; it was shown that location is the dominant factor for the detection of the lesions.

  17. Impact of time-of-flight PET on whole-body oncologic studies: a human observer lesion detection and localization study.

    Science.gov (United States)

    Surti, Suleman; Scheuermann, Joshua; El Fakhri, Georges; Daube-Witherspoon, Margaret E; Lim, Ruth; Abi-Hatem, Nathalie; Moussallem, Elie; Benard, Francois; Mankoff, David; Karp, Joel S

    2011-05-01

    Phantom studies have shown improved lesion detection performance with time-of-flight (TOF) PET. In this study, we evaluate the benefit of fully 3-dimensional, TOF PET in clinical whole-body oncology using human observers to localize and detect lesions in realistic patient anatomic backgrounds. Our hypothesis is that with TOF imaging we achieve improved lesion detection and localization for clinically challenging tasks, with a bigger impact in large patients. One hundred patient studies with normal (18)F-FDG uptake were chosen. Spheres (diameter, 10 mm) were imaged in air at variable locations in the scanner field of view corresponding to lung and liver locations within each patient. Sphere data were corrected for attenuation and merged with patient data to produce fused list-mode data files with lesions added to normal-uptake scans. All list files were reconstructed with full corrections and with or without the TOF kernel using a list-mode iterative algorithm. The images were presented to readers to localize and report the presence or absence of a lesion and their confidence level. The interpretation results were then analyzed to calculate the probability of correct localization and detection, and the area under the localized receiver operating characteristic (LROC) curve. The results were analyzed as a function of scan time per bed position, patient body mass index (BMI patient sizes. With TOF imaging, there was a bigger increase in the area under the LROC curve for larger patients (BMI ≥ 26). Finally, we saw smaller differences in the area under the LROC curve for large and small patients when longer scan times were combined with TOF imaging. A combination of longer scan time (3 min in this study) and TOF imaging provides the best performance for imaging large patients or a low-uptake lesion in small or large patients. This imaging protocol also provides similar performance for all patient sizes for lesions in the same organ type with similar relative uptake

  18. Lesion detection and vascular assessment with modified CTAP and MR imaging of liver

    International Nuclear Information System (INIS)

    Thoeni, R.F.; Werthmuller, W.C.; Warren, R.S.; Mulvihill, S.J.

    1990-01-01

    This paper reports on a special CT arterial portography (CTAP) method with immediate and delayed scans compared to MR imaging of liver with fat-saturation images and angiographic portogram to determine whether CTAP and MR imaging could obviate the angiographic portogram and which imaging method best detects lesions. In 13 patients, CTAP was obtained on a FASTRAK CT scanner in an immediate and delayed dynamic mode with 0.4-sec sections. These CT results were compared to the angiographic portogram and MR results of T1-weighted SR (TR 300, TE 20, NEX 4) and T2-weighted SE (TR 2,000--2,500; TE 20/70; NEX 2) W=with and without fat saturation. CT/MR features analyzed included lesion detection, involvement of portal and hepatic veins, and adenopathy. Features were ranked from 0 = definitely normal to 4 = definitely abnormal

  19. Early Detection of Bone Lesions by Photoscanning with Radioactive Strontium-87m

    Energy Technology Data Exchange (ETDEWEB)

    Kostamis, P.; Constantinides, C.; Papavasiliou, C.; Binopoulos, D.; Sfontouris, J.; Malamos, B. [University of Athens Medical School, ' Alexandra' Hospital, Athens (Greece)

    1969-05-15

    Patients with proven and suspected bone lesions were scanned from 30 min to 3 h after an intravenous injection of 400 {mu}Ci to 1 mCi of {sup 87m}Sr. Many different types of bone tumours were detected, such as osteogenic sarcoma and metastatic cancer of breast, thyroid, lung and other organs. {sup 87m}Sr photoscanning easily demonstrates obvious tumours of the bone which have been visualized on the roentgenogram, but the most important purpose of the present study is the visualization of lesions which were not demonstrated on the conventional roentgenogram. The analysis of the examined cases is discussed. (author)

  20. [Accuracy of computer aided measurement for detecting dental proximal caries lesions in images of cone-beam computed tomography].

    Science.gov (United States)

    Zhang, Z L; Li, J P; Li, G; Ma, X C

    2017-02-09

    Objective: To establish and validate a computer program used to aid the detection of dental proximal caries in the images cone beam computed tomography (CBCT) images. Methods: According to the characteristics of caries lesions in X-ray images, a computer aided detection program for proximal caries was established with Matlab and Visual C++. The whole process for caries lesion detection included image import and preprocessing, measuring average gray value of air area, choosing region of interest and calculating gray value, defining the caries areas. The program was used to examine 90 proximal surfaces from 45 extracted human teeth collected from Peking University School and Hospital of Stomatology. The teeth were then scanned with a CBCT scanner (Promax 3D). The proximal surfaces of the teeth were respectively detected by caries detection program and scored by human observer for the extent of lesions with 6-level-scale. With histologic examination serving as the reference standard, the caries detection program and the human observer performances were assessed with receiver operating characteristic (ROC) curves. Student t -test was used to analyze the areas under the ROC curves (AUC) for the differences between caries detection program and human observer. Spearman correlation coefficient was used to analyze the detection accuracy of caries depth. Results: For the diagnosis of proximal caries in CBCT images, the AUC values of human observers and caries detection program were 0.632 and 0.703, respectively. There was a statistically significant difference between the AUC values ( P= 0.023). The correlation between program performance and gold standard (correlation coefficient r (s)=0.525) was higher than that of observer performance and gold standard ( r (s)=0.457) and there was a statistically significant difference between the correlation coefficients ( P= 0.000). Conclusions: The program that automatically detects dental proximal caries lesions could improve the

  1. Is 3D MPRAGE better than the combination DIR/PSIR for cortical lesion detection at 3T MRI?

    Science.gov (United States)

    Nelson, Flavia; Poonawalla, Aziz; Datta, Sushmita; Wolinsky, Jerry; Narayana, Ponnada

    2014-03-01

    Based on the application of newer magnetic resonance imaging (MRI) acquisition sequences, the detection of cortical lesions (CL) in multiple sclerosis (MS) has significantly improved. Double inversion recovery (DIR) at 3T has increased the detection sensitivity and classification specificity when combined with phase sensitive inversion recovery (PSIR). Previous findings with 3D magnetization prepared rapid acquisition with gradient echo (MPRAGE) sequences, showed improved classification specificity of purely intracortical (IC) and mixed (MX) lesions, compared to the classification based on DIR/PSIR. Direct comparison between the detection of CL by 3D MPRAGE and by DIR/PSIR at 3T has not been evaluated. Eleven subjects were imaged on a 3T magnet. DIR/PSIR and 3D MPRAGE images were reviewed independently. Each image set was reviewed twice; only lesions detected on both sessions were scored. Review time per scan was ~5min for DIR/PSIR and ~15min for 3D MPRAGE. We identified 141 CL (62 IC+79 MX) based on DIR/PSIR images vs. 93 (38 IC+55 MX) based on MPRAGE from all eleven patients. MPRAGE under-detected the number of CL in seven cases and over-detected the number of CL in three, only one case had the same number of CL on both sets of images. Combination DIR/PSIR at 3T is superior to 3D MPRAGE for detection of cortical gray matter lesions in MS. The contrast-to-noise ratio of CL appears to be inferior on the MPRAGE images relative to DIR/PSIR. © 2013 Published by Elsevier B.V.

  2. 111In-Octreotide and 99mTc-MDP scintigraphy in the detection of bone lesions in Langerhans cell histiocytosis

    International Nuclear Information System (INIS)

    Hervas, I.; Bello, P.; Gonzalez-Cabezas, P.; Flores, D.; Perez-Velasco, R.; Torres, I.; Castel, V.; Mateo, A.; Canete, A.

    2002-01-01

    Aim: Langerhans cell histiocytosis (LCH) is a granulomatous disease which can involve multiples sites of the body. Diagnostic imaging is of utmost importance in the management of these patients. Since now radiographic skeletal survey and bone scintigraphy (BS) have been used to assess bone involvement (both with low specificity). Magnetic resonance and CT have been used to assess visceral involvement but with the limitation that can not give information about the functional status. Recently two groups of investigators (Lastoria et al. and Calming et al.) have proposed somatostatin receptor scintigraphy (SSRS) to detect active lesions and for monitoring the response to treatment, due to the somatostatin analogue octreotide binds to the cell membrane of activated lymphocytes expressing somatostatine receptors. The aim of this study is to assess bone and somatostatine receptor scintigraphy in the detection of bone involvement in LCH in children. Visceral involvement has not been assessed due to none of the patients presented it at the moment of the SRS. Methods: 17 scintigraphies (11 SSRS and 6 BS) were performed in seven patients (3 girls and 4 boys) aged at diagnosis: 18 month- 12 years (mean age 6,2 years). The findings obtained in the scintigraphies were compared with clinical evolution and other imaging techniques. Results: All the BS detected the diagnosed lesions, that decreased the uptake after the treatment. In three cases BS detected one unknown bone lesion. Two SSRS could not detect a lesion on right rib in two patients, both at the moment of diagnosis. SSRS was true negative in one patient (clinical and other imaging remission) and true positive in the other four cases. SSRS detected three new unknown bone lesions. SRSS showed decreased uptake after treatment and increased uptake in the relapses. Conclusions: Somatostatin receptor and Bone scintigraphy can be used to detect active LCH bone lesions in children and can help in monitoring the response to

  3. Diagnostic sensitivity and interobserver agreement of radiography and ultrasonography for detecting trochlear ridge osteochondrosis lesions in the equine stifle.

    Science.gov (United States)

    Beccati, Francesca; Chalmers, Heather J; Dante, Sara; Lotto, Eleonora; Pepe, Marco

    2013-01-01

    Osteochondrosis lesions commonly occur on the femoral trochlear ridges in horses and radiography and ultrasonography are routinely used to diagnose these lesions. However, poor correlation has been found between radiographic and arthroscopic findings of affected trochlear ridges. Interobserver agreement for ultrasonographic diagnoses and correlation between ultrasonographic and arthroscopic findings have not been previously described. Objectives of this study were to describe diagnostic sensitivity and interobserver agreement of radiography and ultrasonography for detecting and grading osteochondrosis lesions of the equine trochlear ridges, using arthroscopy as the reference standard. Twenty-two horses were sampled. Two observers independently recorded radiographic and ultrasonographic findings without knowledge of arthroscopic findings. Imaging findings were compared between observers and with arthroscopic findings. Agreement between observers was moderate to excellent (κ 0.48-0.86) for detecting lesions using radiography and good to excellent (κ 0.74-0.87) for grading lesions using radiography. Agreement between observers was good to excellent (κ 0.78-0.94) for detecting lesions using ultrasonography and very good to excellent (κ 0.86-0.93) for grading lesions using ultrasonography. Diagnostic sensitivity was 84-88% for radiography and 100% for ultrasonography. Diagnostic specificity was 89-100% for radiography and 60-82% for ultrasonography. Agreement between radiography and arthroscopy was good (κ 0.64-0.78). Agreement between ultrasonography and arthroscopy was very good to excellent (κ 0.81-0.87). Findings from this study support ultrasound as a preferred method for predicting presence and severity of osteochondrosis lesions involving the femoral trochlear ridges in horses. © 2012 Veterinary Radiology & Ultrasound.

  4. Nonhemorrhagic brain lesions detected by magnetic resonance imaging in closed head injured patients

    International Nuclear Information System (INIS)

    Kinoshita, Yoshihiro; Hiraide, Atsushi; Yoshioka, Toshiji; Sugimoto, Tadashi; Ichimura, Teruhisa; Saito, Akira; Ohno, Yoshioki.

    1990-01-01

    This study evaluated the diagnostic usefulness of magnetic resonance imaging (MRI) in 83 closed head injured patients in whom CT failed to detect focal intra or extraaxial hematoma and/or apparent brain contusion. The patients were divided into three groups on the basis of unconsciousness duration: Group 1 comprised 50 patients diagnosed as having classical cerebral concussion; group 2 comprised 19 patients who presented to the hospital with 6-hr unconsciousness and was recovered within a week; and group 3 comprised 14 patients whose unconsciousness persisted for a week or more. There was no CT evidence of abnormal findings for group 1; and intraventricular hemorrhage and subarachnoid hemorrhage were visualized on CT in 26% and 16%, respectively, for group 2 and 71% and 14% for group 3. Intraaxial nonhemorrhagic lesions were detected on T2-weighted MRI. According to high signal intensity, diffuse axonal injury and cortical contusion could be distinguished; i.e., in the former the corpus callosum, basal ganglia, or brain stem showed a high signal intensity, and in the latter the frontal, temporal, or parietal lobe adjacent to the skull showed a low signal intensity. T2-weighted MRI revealed cortical contusion in 6% for group 1, 37% for group 2, and 14% for group 3; and diffuse axonal injury in 42% for group 2 and 79% for group 3. For 62 patients with normal CT findings, diffuse axonal injury was detected in 88%. There was a good correlation between intraventricular hemorrhage on CT and diffuse axonal injury on MRI. In conclusion, T2-weighted MRI was significantly superior to CT in detecting nonhemorrhagic lesions, and it was of great help for predicting neurologic recovery in closed head injured patients without apparent focal lesions on CT. (N.K.)

  5. Model observer for assessing digital breast tomosynthesis for multi-lesion detection in the presence of anatomical noise

    Science.gov (United States)

    Wen, Gezheng; Markey, Mia K.; Miner Haygood, Tamara; Park, Subok

    2018-02-01

    Model observers are widely used in task-based assessments of medical image quality. The presence of multiple abnormalities in a single set of images, such as in multifocal multicentric breast cancer (MFMC), has an immense clinical impact on treatment planning and survival outcomes. Detecting multiple breast tumors is challenging as MFMC is relatively uncommon, and human observers do not know the number or locations of tumors a priori. Digital breast tomosynthesis (DBT), in which an x-ray beam sweeps over a limited angular range across the breast, has the potential to improve the detection of multiple tumors. However, prior studies of DBT image quality all focus on unifocal breast cancers. In this study, we extended our 2D multi-lesion (ML) channelized Hotelling observer (CHO) into a 3D ML-CHO that detects multiple lesions from volumetric imaging data. Then we employed the 3D ML-CHO to identify optimal DBT acquisition geometries for detection of MFMC. Digital breast phantoms with multiple embedded synthetic lesions were scanned by simulated DBT scanners of different geometries (wide/narrow angular span, different number of projections per scan) to simulate MFMC cases. With new implementations of 3D partial least squares (PLS) and modified Laguerre-Gauss (LG) channels, the 3D ML-CHO made detection decisions based upon the overall information from individual DBT slices and their correlations. Our evaluation results show that: (1) the 3D ML-CHO could achieve good detection performance with a small number of channels, and 3D PLS channels on average outperform the counterpart LG channels; (2) incorporating locally varying anatomical backgrounds and their correlations as in the 3D ML-CHO is essential for multi-lesion detection; (3) the most effective DBT geometry for detection of MFMC may vary when the task of clinical interest changes, and a given DBT geometry may not yield images that are equally informative for detecting MF, MC, and unifocal cancers.

  6. Effectiveness of core biopsy for screen-detected breast lesions under 10 mm: implications for surgical management.

    Science.gov (United States)

    Farshid, Gelareh; Downey, Peter; Pieterse, Steve; Gill, P Grantley

    2017-09-01

    Technical advances have improved the detection of small mammographic lesions. In the context of mammographic screening, accurate sampling of these lesions by percutaneous biopsy is crucial in limiting diagnostic surgical biopsies, many of which show benign results. Women undergoing core biopsy between January 1997 and December 2007 for core histology, 345 women (43.0%) were immediately cleared of malignancy and 300 (37.4%) were referred for definitive cancer treatment. A further 157 women (19.6%) required diagnostic surgical biopsy because of indefinite or inadequate core results or radiological-pathological discordance, and one woman (0.1%) needed further imaging in 12 months. The open biopsies were malignant in 46 (29.3%) cases. The positive predictive value of malignant core biopsy was 100%. The negative predictive value for benign core results was 97.7%, and the false-negative rate was 2.6%. The lesion could not be visualized after core biopsy in 5.1% of women and in 4.0% of women with malignant core biopsies excision specimens did not contain residual malignancy. Excessive delays in surgery because of complications of core biopsy were not reported. Even at this small size range, core biopsy evaluation of screen-detected breast lesions is highly effective and accurate. A lesion miss rate of 3.1% and under-representation of lesions on core samples highlight the continued need for multidisciplinary collaboration and selective use of diagnostic surgical biopsy. © 2015 Royal Australasian College of Surgeons.

  7. IMAGE PROCESSING FOR DETECTION OF ORAL WHITE SPONGE NEVUS LESIONS

    Directory of Open Access Journals (Sweden)

    Rajdeep Mitra

    2016-12-01

    Full Text Available White Sponge Nevus is a rear hereditary disease in human causes incurable white lesions in oral mucosa. Appropriate history, clinical examination along with biopsy and cytological studies are helpful for diagnosis of this disorder. Identification can also be made in alternative way by applying image processing technique using Watershed segmentation with MATLAB software. The applied techniques are effective and reliable for early accurate detection of the disease as alternative of expertise clinical and time taking laboratory investigations.

  8. Digital breast tomosynthesis (DBT) to characterize MRI-detected additional lesions unidentified at targeted ultrasound in newly diagnosed breast cancer patients

    International Nuclear Information System (INIS)

    Mariscotti, Giovanna; Durando, Manuela; Regini, Elisa; Fornari, Alberto; Fonio, Paolo; Gandini, Giovanni; Houssami, Nehmat; Campanino, Pier Paolo; Bussone, Riccardo; Castellano, Isabella; Sapino, Anna

    2015-01-01

    Preoperative breast magnetic resonance (MR) often generates additional suspicious findings needing further investigations. Targeted breast ultrasound (US) is the standard tool to characterize MR additional lesions. The purpose of this study is to evaluate the potential role of digital breast tomosynthesis (DBT) to characterize MR detected additional findings, unidentified at targeted breast US. This prospective study included women who a) had biopsy-proven, newly diagnosed breast cancers detected at conventional 2D mammography and/or US, referred to breast MR for tumour staging; and b) had DBT if additional MR findings were not detected at targeted ('second look') US. In 520 patients, MR identified 164 (in 114 women, 22 %) additional enhancing lesions. Targeted US identified 114/164 (69.5 %) of these, whereas 50/164 (30.5 %) remained unidentified. DBT identified 32/50 of these cases, increasing the overall characterization of MR detected additional findings to 89.0 % (146/164). Using DBT the identified lesions were significantly more likely to be malignant than benign MR-detected additional lesions (p = 0.04). DBT improves the characterization of additional MR findings not identified at targeted breast US in preoperative breast cancer staging. (orig.)

  9. Digital breast tomosynthesis (DBT) to characterize MRI-detected additional lesions unidentified at targeted ultrasound in newly diagnosed breast cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Mariscotti, Giovanna; Durando, Manuela; Regini, Elisa; Fornari, Alberto; Fonio, Paolo; Gandini, Giovanni [Breast Imaging Service, Radiology - University of Turin, Department of Diagnostic Imaging and Radiotherapy, A.O.U. Citta della Salute e della Scienza, Torino (Italy); Houssami, Nehmat [University of Sydney, Screening and Test Evaluation Program, School of Public Health, Sydney Medical School, Sydney, NSW (Australia); Campanino, Pier Paolo [Ospedale Koelliker, Breast Imaging Service, Torino (Italy); Bussone, Riccardo [A.O.U. Citta della Salute e della Scienza of Turin, SSCVD Breast Surgery. Department of Surgery, Torino (Italy); Castellano, Isabella; Sapino, Anna [University of Turin, Department of Biomedical Sciences and Human Oncology, A.O.U. Citta della Salute e della Scienza, Torino (Italy)

    2015-09-15

    Preoperative breast magnetic resonance (MR) often generates additional suspicious findings needing further investigations. Targeted breast ultrasound (US) is the standard tool to characterize MR additional lesions. The purpose of this study is to evaluate the potential role of digital breast tomosynthesis (DBT) to characterize MR detected additional findings, unidentified at targeted breast US. This prospective study included women who a) had biopsy-proven, newly diagnosed breast cancers detected at conventional 2D mammography and/or US, referred to breast MR for tumour staging; and b) had DBT if additional MR findings were not detected at targeted ('second look') US. In 520 patients, MR identified 164 (in 114 women, 22 %) additional enhancing lesions. Targeted US identified 114/164 (69.5 %) of these, whereas 50/164 (30.5 %) remained unidentified. DBT identified 32/50 of these cases, increasing the overall characterization of MR detected additional findings to 89.0 % (146/164). Using DBT the identified lesions were significantly more likely to be malignant than benign MR-detected additional lesions (p = 0.04). DBT improves the characterization of additional MR findings not identified at targeted breast US in preoperative breast cancer staging. (orig.)

  10. An Optimized Clustering Approach for Automated Detection of White Matter Lesions in MRI Brain Images

    Directory of Open Access Journals (Sweden)

    M. Anitha

    2012-04-01

    Full Text Available Settings White Matter lesions (WMLs are small areas of dead cells found in parts of the brain. In general, it is difficult for medical experts to accurately quantify the WMLs due to decreased contrast between White Matter (WM and Grey Matter (GM. The aim of this paper is to
    automatically detect the White Matter Lesions which is present in the brains of elderly people. WML detection process includes the following stages: 1. Image preprocessing, 2. Clustering (Fuzzy c-means clustering, Geostatistical Possibilistic clustering and Geostatistical Fuzzy clustering and 3.Optimization using Particle Swarm Optimization (PSO. The proposed system is tested on a database of 208 MRI images. GFCM yields high sensitivity of 89%, specificity of 94% and overall accuracy of 93% over FCM and GPC. The clustered brain images are then subjected to Particle Swarm Optimization (PSO. The optimized result obtained from GFCM-PSO provides sensitivity of 90%, specificity of 94% and accuracy of 95%. The detection results reveals that GFCM and GFCMPSO better localizes the large regions of lesions and gives less false positive rate when compared to GPC and GPC-PSO which captures the largest loads of WMLs only in the upper ventral horns of the brain.

  11. Detection and analysis of human papillomavirus 16 and 18 homologous DNA sequences in oral lesions.

    Science.gov (United States)

    Wen, S; Tsuji, T; Li, X; Mizugaki, Y; Hayatsu, Y; Shinozaki, F

    1997-01-01

    The prevalence of human papillomavirus (HPV) 16 and 18 was investigated in oral lesions of the population of northeast China including squamous cell carcinomas (SCCs), candida leukoplakias, lichen planuses and papillomas, by southern blot hybridization with polymerase chain reaction (PCR). Amplified HPV16 and 18 E6 DNA was analyzed by cycle sequence. HPV DNA was detected in 14 of 45 SCCs (31.1%). HPV18 E6 DNA and HPV16 E6. DNA were detected in 24.4% and 20.0% of SCCs. respectively. Dual infection of both HPV 16 and HPV 18 was detected in 6 of 45 SCCs (13.3%), but not in other oral lesions. HPV 18 E6 DNA was also detected in 2 of 3 oral candida leukoplakias, but in none of the 5 papillomas. Our study indicated that HPV 18 infection might be more frequent than HPV 16 infection in oral SCCs in northeast Chinese, dual infection of high risk HPV types was restricted in oral SCCs, and that HPV infection might be involved in the pathogenesis of oral candida leukoplakia.

  12. Effect of dose reduction on the detection of mammographic lesions: A mathematical observer model analysis

    International Nuclear Information System (INIS)

    Chawla, Amarpreet S.; Samei, Ehsan; Saunders, Robert; Abbey, Craig; Delong, David

    2007-01-01

    The effect of reduction in dose levels normally used in mammographic screening procedures on the detection of breast lesions were analyzed. Four types of breast lesions were simulated and inserted into clinically-acquired digital mammograms. Dose reduction by 50% and 75% of the original clinically-relevant exposure levels were simulated by adding corresponding simulated noise into the original mammograms. The mammograms were converted into luminance values corresponding to those displayed on a clinical soft-copy display station and subsequently analyzed by Laguerre-Gauss and Gabor channelized Hotelling observer models for differences in detectability performance with reduction in radiation dose. Performance was measured under a signal known exactly but variable detection task paradigm in terms of receiver operating characteristics (ROC) curves and area under the ROC curves. The results suggested that luminance mapping of digital mammograms affects performance of model observers. Reduction in dose levels by 50% lowered the detectability of masses with borderline statistical significance. Dose reduction did not have a statistically significant effect on detection of microcalcifications. The model results indicate that there is room for optimization of dose level in mammographic screening procedures

  13. A comparison of lesion detection and conspicuity on T2-weighted images (T2 FFE), FLAIR and diffusion-weighted images in patients with traumatic brain injury

    International Nuclear Information System (INIS)

    Kwon, Eun Yong; Lee, Myeong sub; Kim, Myung Soon; Hong, In Soo; Kim, Young Ju; Whang, Gum

    2001-01-01

    To compare the lesion detectability and conspicuity in traumatic brain injury on T-2 FFE, FLAIR and diffusion weighted imaging (DWI) sequences. Thirty-three patients who underwent MR brain imaging after traumatic brain injury were reviewed. T-2 FFE, FLAIR and diffusion-weighted MR sequences were obtained and were compared in terms of the detectability and conspicuity of intra- and extra-axial lesions which showed abnormal signal intensities. Among 33 patients, a total of 108 lesions were found, T-2 FFE sequences detected 88(81%) of these, FLAIR sequences 91%(84%), and diffusion-weighted sequences 57(52%). In the case of petechial hemorrhagic lesions, 16 were detected by T-2 FFE imaging but only one by FLAIR and one by DWI. Sixteen extra-axial lesions (73%) were detected by T-2 FFE, 21 (95%) by FLAIR, and 11(50%) by DWI. Lesion conspicuity on FLAIR images was judged superior to that on T-2 FFE and diffusion-weighted images in 42 lesions (75%). Eleven extra-axial Lesions (92%) were more conspicuous on FLAIR than on T-2 FFE and DWI. For detecting traumatic brain lesions and determining their conspicuity, FLAIR imaging was more useful than T-2 FFE and diffusion weighting , while T-2 FFE imaging was more sensitive for the detecion of petechial hemorrhage. Although diffusion-weighted imaging was generally inferior to both FLAIR and T-2 FFE in terms of lesion detection and conspicuity, for some lesions it was superior. The results suggest that images obtained at each pulse sequence can be used as complementary imaging sequences, and that in traumatic brain injury, the acquisition of FLAIR, T-2 FFE and diffusion-weighted images is useful

  14. Screen film vs full-field digital mammography: image quality, detectability and characterization of lesions

    International Nuclear Information System (INIS)

    Obenauer, S.; Luftner-Nagel, S.; Heyden, D. von; Baum, F.; Grabbe, E.; Munzel, U.

    2002-01-01

    The objective of this study was to compare screen-film mammography (SFM) to full-field digital mammography (FFDM) regarding image quality as well as detectability and characterization of lesions using equivalent images of the same patient acquired with both systems. Two mammography units were used, one with a screen-film system (Senographe DMR) and the other with a digital detector (Senographe 2000D, both GEMS). Screen-film and digital mammograms were performed on 55 patients with cytologically or histologically proven tumors on the same day. Together with these, 75 digital mammograms of patients without tumor and the corresponding previous screen-film mammograms not older than 1.5 years were reviewed by three observers in a random order. Contrast, exposure, and the presence of artifacts were evaluated. Different details, such as the skin, the retromamillary region, and the parenchymal structures, were judged according to a three-point ranking scale. Finally, the detectability of microcalcifications and lesions were compared and correlated to histology. Image contrast was judged to be good in 76%, satisfactory in 20%, and unsatisfactory in 4% of screen-film mammograms. Digital mammograms were judged to be good in 99% and unsatisfactory in 1% of cases. Improper exposure of screen-film system occurred in 18% (10% overexposed and 8% underexposed). Digital mammograms were improperly exposed in 4% of all cases but were of acceptable quality after post-processing. Artifacts, most of them of no significance, were found in 78% of screen-film and in none of the digital mammograms. Different anatomical regions, such as the skin, the retromamillary region, and dense parenchymal areas, were better visualized in digital than in screen-film mammography. All malignant tumors were seen by the three radiologists; however, digital mammograms allowed a better characterization of these lesions to the Breast Imaging Reporting and Data System (BI-RADSZZZ;) categories (FFDM better than

  15. Inter- and intraobserver variability of MR arthrography in the detection and classification of superior labral anterior posterior (SLAP) lesions: evaluation in 78 cases with arthroscopic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Holzapfel, Konstantin; Waldt, Simone; Bruegel, Melanie; Rummeny, Ernst J.; Woertler, Klaus [Technische Universitaet Muenchen, Department of Radiology, Klinikum rechts der Isar, Munich (Germany); Paul, Jochen; Imhoff, Andreas B. [Technische Universitaet Muenchen, Department of Sports Orthopedics, Klinikum rechts der Isar, Munich (Germany); Heinrich, Petra [Technische Universitaet Muenchen, Institute of Medical Statistics and Epidemiology, Klinikum rechts der Isar, Munich (Germany)

    2010-03-15

    The purpose of this study was to determine inter- and intraobserver variability of MR arthrography of the shoulder in the detection and classification of superior labral anterior posterior (SLAP) lesions. MR arthrograms of 78 patients who underwent MR arthrography before arthroscopy were retrospectively analysed by three blinded readers for the presence and type of SLAP lesions. MR arthrograms were reviewed twice by each reader with a time interval of 4 months between the two readings. Inter- and intraobserver agreement for detection and classification of SLAP lesions were calculated using {kappa} coefficients. Arthroscopy confirmed 48 SLAP lesions: type I (n = 4), type II (n = 37), type III (n = 3), type IV (n = 4). Sensitivity and specificity for detecting SLAP lesions with MR arthrography for each reader were 88.6%/93.3%, 90.9%/80.0% and 86.4%/76.7%. MR arthrographic and arthroscopic grading were concurrent for 72.7%, 68.2% and 70.5% of SLAP lesions for readers 1-3, respectively. Interobserver agreement was excellent ({kappa} = 0.82) for detection and substantial ({kappa} = 0.63) for classification of SLAP lesions. For each reader intraobserver agreement was excellent for detection ({kappa} = 0.93, {kappa} = 0.97, {kappa} = 0.97) and classification ({kappa} = 0.94, {kappa} = 0.84, {kappa} = 0.93) of SLAP lesions. MR arthrography allows reliable and accurate detection of SLAP lesions. In addition, SLAP lesions can be diagnosed and classified with substantial to excellent inter- and intraobserver agreement. (orig.)

  16. Inter- and intraobserver variability of MR arthrography in the detection and classification of superior labral anterior posterior (SLAP) lesions: evaluation in 78 cases with arthroscopic correlation

    International Nuclear Information System (INIS)

    Holzapfel, Konstantin; Waldt, Simone; Bruegel, Melanie; Rummeny, Ernst J.; Woertler, Klaus; Paul, Jochen; Imhoff, Andreas B.; Heinrich, Petra

    2010-01-01

    The purpose of this study was to determine inter- and intraobserver variability of MR arthrography of the shoulder in the detection and classification of superior labral anterior posterior (SLAP) lesions. MR arthrograms of 78 patients who underwent MR arthrography before arthroscopy were retrospectively analysed by three blinded readers for the presence and type of SLAP lesions. MR arthrograms were reviewed twice by each reader with a time interval of 4 months between the two readings. Inter- and intraobserver agreement for detection and classification of SLAP lesions were calculated using κ coefficients. Arthroscopy confirmed 48 SLAP lesions: type I (n = 4), type II (n = 37), type III (n = 3), type IV (n = 4). Sensitivity and specificity for detecting SLAP lesions with MR arthrography for each reader were 88.6%/93.3%, 90.9%/80.0% and 86.4%/76.7%. MR arthrographic and arthroscopic grading were concurrent for 72.7%, 68.2% and 70.5% of SLAP lesions for readers 1-3, respectively. Interobserver agreement was excellent (κ = 0.82) for detection and substantial (κ = 0.63) for classification of SLAP lesions. For each reader intraobserver agreement was excellent for detection (κ = 0.93, κ = 0.97, κ = 0.97) and classification (κ = 0.94, κ = 0.84, κ = 0.93) of SLAP lesions. MR arthrography allows reliable and accurate detection of SLAP lesions. In addition, SLAP lesions can be diagnosed and classified with substantial to excellent inter- and intraobserver agreement. (orig.)

  17. The Problems with the Kappa Statistic as a Metric of Interobserver Agreement on Lesion Detection Using a Third-reader Approach When Locations Are Not Prespecified.

    Science.gov (United States)

    Shih, Joanna H; Greer, Matthew D; Turkbey, Baris

    2018-03-16

    To point out the problems with Cohen kappa statistic and to explore alternative metrics to determine interobserver agreement on lesion detection when locations are not prespecified. Use of kappa and two alternative methods, namely index of specific agreement (ISA) and modified kappa, for measuring interobserver agreement on the location of detected lesions are presented. These indices of agreement are illustrated by application to a retrospective multireader study in which nine readers detected and scored prostate cancer lesions in 163 consecutive patients (n = 110 cases, n = 53 controls) using the guideline of Prostate Imaging Reporting and Data System version 2 on multiparametric magnetic resonance imaging. The proposed modified kappa, which properly corrects for the amount of agreement by chance, is shown to be approximately equivalent to the ISA. In the prostate cancer data, average kappa, modified kappa, and ISA equaled 30%, 55%, and 57%, respectively, for all lesions and 20%, 87%, and 87%, respectively, for index lesions. The application of kappa could result in a substantial downward bias in reader agreement on lesion detection when locations are not prespecified. ISA is recommended for assessment of reader agreement on lesion detection. Published by Elsevier Inc.

  18. Detection of questionable occlusal carious lesions using an electrical bioimpedance method with fractional electrical model

    Energy Technology Data Exchange (ETDEWEB)

    Morais, A. P. [Biomedical Engineering Program, COPPE, Rio de Janeiro (Brazil); Salgado de Oliveira University, Marechal Deodoro Street, 217 – Centro, Niterói, Rio de Janeiro (Brazil); Pino, A. V. [Biomedical Engineering Program, COPPE, Rio de Janeiro (Brazil); Souza, M. N. [Biomedical Engineering Program, COPPE, Rio de Janeiro (Brazil); Electronics Department at Polytechnic School, Federal University of Rio de Janeiro, Centro de Tecnologia Bloco H sala 217, Ilha do Fundão, Rio de Janeiro (Brazil)

    2016-08-15

    This in vitro study evaluated the diagnostic performance of an alternative electric bioimpedance spectroscopy technique (BIS-STEP) detect questionable occlusal carious lesions. Six specialists carried out the visual (V), radiography (R), and combined (VR) exams of 57 sound or non-cavitated occlusal carious lesion teeth classifying the occlusal surfaces in sound surface (H), enamel caries (EC), and dentinal caries (DC). Measurements were based on the current response to a step voltage excitation (BIS-STEP). A fractional electrical model was used to predict the current response in the time domain and to estimate the model parameters: Rs and Rp (resistive parameters), and C and α (fractional parameters). Histological analysis showed caries prevalence of 33.3% being 15.8% hidden caries. Combined examination obtained the best traditional diagnostic results with specificity = 59.0%, sensitivity = 70.9%, and accuracy = 60.8%. There were statistically significant differences in bioimpedance parameters between the H and EC groups (p = 0.016) and between the H and DC groups (Rs, p = 0.006; Rp, p = 0.022, and α, p = 0.041). Using a suitable threshold for the Rs, we obtained specificity = 60.7%, sensitivity = 77.9%, accuracy = 73.2%, and 100% of detection for deep lesions. It can be concluded that BIS-STEP method could be an important tool to improve the detection and management of occlusal non-cavitated primary caries and pigmented sites.

  19. Detection of questionable occlusal carious lesions using an electrical bioimpedance method with fractional electrical model

    International Nuclear Information System (INIS)

    Morais, A. P.; Pino, A. V.; Souza, M. N.

    2016-01-01

    This in vitro study evaluated the diagnostic performance of an alternative electric bioimpedance spectroscopy technique (BIS-STEP) detect questionable occlusal carious lesions. Six specialists carried out the visual (V), radiography (R), and combined (VR) exams of 57 sound or non-cavitated occlusal carious lesion teeth classifying the occlusal surfaces in sound surface (H), enamel caries (EC), and dentinal caries (DC). Measurements were based on the current response to a step voltage excitation (BIS-STEP). A fractional electrical model was used to predict the current response in the time domain and to estimate the model parameters: Rs and Rp (resistive parameters), and C and α (fractional parameters). Histological analysis showed caries prevalence of 33.3% being 15.8% hidden caries. Combined examination obtained the best traditional diagnostic results with specificity = 59.0%, sensitivity = 70.9%, and accuracy = 60.8%. There were statistically significant differences in bioimpedance parameters between the H and EC groups (p = 0.016) and between the H and DC groups (Rs, p = 0.006; Rp, p = 0.022, and α, p = 0.041). Using a suitable threshold for the Rs, we obtained specificity = 60.7%, sensitivity = 77.9%, accuracy = 73.2%, and 100% of detection for deep lesions. It can be concluded that BIS-STEP method could be an important tool to improve the detection and management of occlusal non-cavitated primary caries and pigmented sites.

  20. Microaneurysms detection with the radon cliff operator in retinal fundus images

    Energy Technology Data Exchange (ETDEWEB)

    Giancardo, Luca [ORNL; Meriaudeau, Fabrice [ORNL; Karnowski, Thomas Paul [ORNL; Tobin Jr, Kenneth William [ORNL; Li, Yaquin [University of Tennessee, Knoxville (UTK); Chaum, Edward [University of Tennessee, Knoxville (UTK)

    2010-01-01

    Diabetic Retinopathy (DR) is one of the leading causes of blindness in the industrialized world. Early detection is the key in providing effective treatment. However, the current number of trained eye care specialists is inadequate to screen the increasing number of diabetic patients. In recent years, automated and semi-automated systems to detect DR with color fundus images have been developed with encouraging, but not fully satisfactory results. In this study we present the initial results of a new technique for the detection and localization of microaneurysms, an early sign of DR. The algorithm is based on three steps: candidates selection, the actual microaneurysms detection and a final probability evaluation. We introduce the new Radon Cliff operator which is our main contribution to the field. Making use of the Radon transform, the operator is able to detect single noisy Gaussian-like circular structures regardless of their size or strength. The advantages over existing microaneurysms detectors are manifold: the size of the lesions can be unknown, it automatically distinguishes lesions from the vasculature and it provides a fair approach to microaneurysm localization even without post-processing the candidates with machine learning techniques, facilitating the training phase. The algorithm is evaluated on a publicly available dataset from the Retinopathy Online Challenge.

  1. Microaneurysms detection with the radon cliff operator in retinal fundus images

    Science.gov (United States)

    Giancardo, Luca; Mériaudeau, Fabrice; Karnowski, Thomas P.; Tobin, Kenneth W.; Li, Yaqin; Chaum, Edward

    2010-03-01

    Diabetic Retinopathy (DR) is one of the leading causes of blindness in the industrialized world. Early detection is the key in providing effective treatment. However, the current number of trained eye care specialists is inadequate to screen the increasing number of diabetic patients. In recent years, automated and semi-automated systems to detect DR with color fundus images have been developed with encouraging, but not fully satisfactory results. In this study we present the initial results of a new technique for the detection and localization of microaneurysms, an early sign of DR. The algorithm is based on three steps: candidates selection, the actual microaneurysms detection and a final probability evaluation. We introduce the new Radon Cliff operator which is our main contribution to the field. Making use of the Radon transform, the operator is able to detect single noisy Gaussian-like circular structures regardless of their size or strength. The advantages over existing microaneurysms detectors are manifold: the size of the lesions can be unknown, it automatically distinguishes lesions from the vasculature and it provides a fair approach to microaneurysm localization even without post-processing the candidates with machine learning techniques, facilitating the training phase. The algorithm is evaluated on a publicly available dataset from the Retinopathy Online Challenge.

  2. Human papillomavirus in oral lesions Virus papiloma humano en lesiones orales

    Directory of Open Access Journals (Sweden)

    Joaquín V. Gónzalez

    2007-08-01

    Full Text Available Growing evidence suggests a role for human papillomavirus (HPV in oral cancer; however its involvement is still controversial. This study evaluates the frequency of HPV DNA in a variety of oral lesions in patients from Argentina. A total of 77 oral tissue samples from 66 patients were selected (cases; the clinical-histopathological diagnoses corresponded to: 11 HPV- associated benign lesions, 8 non-HPV associated benign lesions, 33 premalignant lesions and 25 cancers. Sixty exfoliated cell samples from normal oral mucosa were used as controls. HPV detection and typing were performed by polymerase chain reaction (PCR using primers MY09, 11, combined with RFLP or alternatively PCR using primers GP5+, 6+ combined with dot blot hybridization. HPV was detected in 91.0% of HPV- associated benign lesions, 14.3% of non-HPV associated benign lesions, 51.5% of preneoplasias and 60.0% of cancers. No control sample tested HPV positive. In benign HPV- associated lesions, 30.0% of HPV positive samples harbored high-risk types, while in preneoplastic lesions the value rose to 59.9%. In cancer lesions, HPV detection in verrucous carcinoma was 88.9% and in squamous cell carcinoma 43.8%, with high-risk type rates of 75.5% and 85.6%, respectively. The high HPV frequency detected in preneoplastic and neoplastic lesions supports an HPV etiological role in at least a subset of oral cancers.Crecientes evidencias sugieren que el virus Papiloma humano (HPV tiene un rol en el cáncer oral; sin embargo su participación es todavía controvertida. Este estudio evalúa la frecuencia de ADN de HPV en una variedad de lesiones orales de pacientes de Argentina. Se seleccionaron 77 muestras de tejido oral de 66 pacientes (casos; el diagnóstico histo-patológico correspondió a: 11 lesiones benignas asociadas a HPV, 8 lesiones benignas no asociadas a HPV, 33 lesiones premalignas y 25 cánceres. Como controles se usaron 60 muestras de células exfoliadas de mucosa oral normal. La

  3. A computer simulation study comparing lesion detection accuracy with digital mammography, breast tomosynthesis, and cone-beam CT breast imaging

    International Nuclear Information System (INIS)

    Gong Xing; Glick, Stephen J.; Liu, Bob; Vedula, Aruna A.; Thacker, Samta

    2006-01-01

    Although conventional mammography is currently the best modality to detect early breast cancer, it is limited in that the recorded image represents the superposition of a three-dimensional (3D) object onto a 2D plane. Recently, two promising approaches for 3D volumetric breast imaging have been proposed, breast tomosynthesis (BT) and CT breast imaging (CTBI). To investigate possible improvements in lesion detection accuracy with either breast tomosynthesis or CT breast imaging as compared to digital mammography (DM), a computer simulation study was conducted using simulated lesions embedded into a structured 3D breast model. The computer simulation realistically modeled x-ray transport through a breast model, as well as the signal and noise propagation through a CsI based flat-panel imager. Polyenergetic x-ray spectra of Mo/Mo 28 kVp for digital mammography, Mo/Rh 28 kVp for BT, and W/Ce 50 kVp for CTBI were modeled. For the CTBI simulation, the intensity of the x-ray spectra for each projection view was determined so as to provide a total average glandular dose of 4 mGy, which is approximately equivalent to that given in conventional two-view screening mammography. The same total dose was modeled for both the DM and BT simulations. Irregular lesions were simulated by using a stochastic growth algorithm providing lesions with an effective diameter of 5 mm. Breast tissue was simulated by generating an ensemble of backgrounds with a power law spectrum, with the composition of 50% fibroglandular and 50% adipose tissue. To evaluate lesion detection accuracy, a receiver operating characteristic (ROC) study was performed with five observers reading an ensemble of images for each case. The average area under the ROC curves (A z ) was 0.76 for DM, 0.93 for BT, and 0.94 for CTBI. Results indicated that for the same dose, a 5 mm lesion embedded in a structured breast phantom was detected by the two volumetric breast imaging systems, BT and CTBI, with statistically

  4. Wallerian degeneration of the corticodescending tract in the cerebral peduncle following a supratentorial cerebrovascular lesion detected by MRI

    International Nuclear Information System (INIS)

    Waragai, Masaaki; Iwabuchi, Sadamu

    1993-01-01

    We studied Wallerian degeneration of the corticodescending tract in the cerebral peduncle following a supratentorial cerebrovascular lesion by MRI. A total of 57 patients with palsy following a supratenotorial cerebrovascular lesion were prospectively studied. Wallerian degeneration was detected as a high signal intensity (HSI) in 37 patients between 70 days and 100 days after the onset, but not detected in the remaining 27 patients. Patient with as HSI in all areas of the cerebral peduncle had a large lesion involving the hemisphere. Patient with an HSI at the center of the cerebral peduncle had a lesion confined to the paracentral gyrus, precentral gyrus, corona radiata or posterior limb of the internal capsule. Patient with an HSI at the lateral side of the cerebral peduncle had a lesion of parietal lobe or temporal lobe which spares the corticospinal tract originating from the paracentral gyrus, precentral gyrus, corona radiata or posterior limb of the internal capsule. These findings suggest that as HSI at the center of the cerebral peduncle may reveal Wallerian degeneration of the corticospinal tract, and an HSI at the lateral side of the cerebral peduncle may show Wallerian degeneration of the corticopontine tract. The functional recovery of paresis was poor in all patients with an HSI at the center of the cerebral peduncle, while it was good in all patients without an HSI in that region. Our data suggested that somatotopical localization of the corticodescending tract in the cerebral peduncle may be identified by detecting Wallerian degeneration following a supratentorial lesion, and the functional recovery of patients with paresis could be predicted according to presence or absence of Wallerian degeneration at the center of the cerebral peduncle. (author)

  5. Going With the Flow: An Aid in Detecting and Differentiating Bronchopulmonary Sequestrations and Hybrid Lesions.

    Science.gov (United States)

    Oliver, Edward R; DeBari, Suzanne E; Giannone, Mariann M; Pogoriler, Jennifer E; Johnson, Ann M; Horii, Steven C; Gebb, Juliana S; Howell, Lori J; Adzick, N Scott; Coleman, Beverly G

    2018-02-01

    68 of 73 hybrid lesions. Ultrasound is most accurate for systemic feeding artery detection in bronchopulmonary sequestrations and hybrid lesions and can also type the lesions as intralobar or extralobar when draining veins are evaluated. © 2017 by the American Institute of Ultrasound in Medicine.

  6. Respiratory gated PET/CT in a European multicentre retrospective study: added diagnostic value in detection and characterization of lung lesions

    Energy Technology Data Exchange (ETDEWEB)

    Guerra, Luca; Elisei, Federica [San Gerardo Hospital, Nuclear Medicine, Monza (Italy); De Ponti, Elena [San Gerardo Hospital, Medical Physics, Monza (Italy); Bettinardi, Valentino; Picchio, Maria [San Raffaele Scientific Institute, Nuclear Medicine, Milan (Italy); National Research Council, Institute for Bioimaging and Molecular Physiology, Milan (Italy); Landoni, Claudio [San Raffaele Scientific Institute, Nuclear Medicine, Milan (Italy); University of Milano-Bicocca, Milan (Italy); Gilardi, Maria Carla [San Raffaele Scientific Institute, Nuclear Medicine, Milan (Italy); National Research Council, Institute for Bioimaging and Molecular Physiology, Milan (Italy); University of Milano-Bicocca, Tecnomed Foundation, Milan (Italy); Versari, Annibale [Scientific Institute Santa Maria Nuova Hospital, Nuclear Medicine, Reggio Emilia (Italy); Fioroni, Federica [Scientific Institute Santa Maria Nuova Hospital, Medical Physics, Reggio Emilia (Italy); Dziuk, Miroslaw [Masovian PET-CT Centre, Department of Nuclear Medicine, Military Institute of Medicine, Warsaw (Poland); Koza, Magdalena [Masovian PET-CT Centre, Euromedic Diagnostic, Warsaw (Poland); Ahond-Vionnet, Renee; Collin, Bertrand [Hopital Pierre Beregovoy, Service de Medecine Nucleaire, Nevers (France); Messa, Cristina [San Gerardo Hospital, Nuclear Medicine, Monza (Italy); National Research Council, Institute for Bioimaging and Molecular Physiology, Milan (Italy); University of Milano-Bicocca, Tecnomed Foundation, Milan (Italy)

    2012-09-15

    The aim of our work is to evaluate the added diagnostic value of respiratory gated (4-D) positron emission tomography/computed tomography (PET/CT) in lung lesion detection/characterization in a large patient population of a multicentre retrospective study. The data of 155 patients (89 men, 66 women, mean age 63.9 {+-} 11.1 years) from 5 European centres and submitted to standard (3-D) and 4-D PET/CT were retrospectively analysed. Overall, 206 lung lesions were considered for the analysis (mean {+-} SD lesions dimension 14.7 {+-} 11.8 mm). Maximum standardized uptake values (SUV{sub max}) and lesion detectability were assessed for both 3-D and 4-D PET/CT studies; 3-D and 4-D PET/CT findings were compared to clinical follow-up as standard reference. Mean {+-} SD 3-D and 4-D SUV{sub max} values were 5.2 {+-} 5.1 and 6.8 {+-} 6.1 (p < 0.0001), respectively, with an average percentage increase of 30.8 %. In 3-D PET/CT, 86 of 206 (41.7 %) lesions were considered positive, 70 of 206 (34 %) negative and 50 of 206 (24.3 %) equivocal, while in 4-D PET/CT 117 of 206 (56.8 %) lesions were defined as positive, 80 of 206 (38.8 %) negative and 9 of 206 (4.4 %) equivocal. In 34 of 50 (68 %) 3-D equivocal lesions follow-up data were available and the presence of malignancy was confirmed in 21 of 34 (61.8 %) lesions, while in 13 of 34 (38.2 %) was excluded. In 31 of these 34 controlled lesions, 20 of 34 (58.8 %) and 11 of 34 (32.4 %) were correctly classified by 4-D PET/CT as positive and negative, respectively; 3 of 34 (8.8 %) remained equivocal. With equivocal lesions classified as positive, the overall accuracy of 3-D and 4-D was 85.7 and 92.8 %, respectively, while the same figures were 80.5 and 94.2 % when equivocal lesions were classified as negative. The respiratory gated PET/CT technique is a valuable clinical tool in diagnosing lung lesions, improving quantification and confidence in reporting, reducing 3-D undetermined findings and increasing the overall accuracy in lung

  7. Comparision between biphasic helical CT and dynamic gadolinium-enhanced MR in the detection and characterization of focal hepatic lesions in cirrhotic patients

    International Nuclear Information System (INIS)

    Puig, J.; Martin, J.; Donoso, L.; Falco, J.; Rue, M.

    1997-01-01

    To assess the agreement between biphasic helical computerized tomography (BHCT) and dynamic gadolinium-enhanced magnetic resonance (MR) in the detection and characterization of focal hepatic lesions in a group of cirrhotic patients. A prospective study was done in 50 cirrhotic patients suspected of having hepatocarcinoma (HC) on the basis of ultrasonographic images evaluated by means of BHCT and dynamic gadolinium-enhanced MR using fast low-angle shot (FLASH) sequences (110-135/4/90 degree centigree). The images were assessed jointly by four radiologists. Between the two techniques, a total of 83 lesions were detected. MR disclosed more lesions (n=79) than BHCT (n=67) (p<0.005). Moreover, 25 of the lesions that were visible by both techniques were more clearly evident in MR images (p<0.01). MR correctly classified 6 of 7 benign lesions (85%) and 49 of 66 malignant ones (74%). BHCT correctly classifed 2 of 7 benign lesions (28%) and 32 of 66 malignant ones (48%). The sensitivities of MR and BHCT for the characterization of these lesions were 74% and 48%, respectively (p=0.0009), while the respective specificities were 86% and 29% (P<0.001). Dynamic gadolinium-enhanced MR with FLASH sequences is more efficient than BHCT in the detection and characterization of focal lesions in cirrhotic patients. (Author) 37 refs

  8. Detection of early lung cancer lesions in surgical resections and in bronchial and transbronchial biopsies

    International Nuclear Information System (INIS)

    Rott, T.; Jerse, M.; Tercelj, M.; Erzen, J.

    2006-01-01

    Background. Overall bad prognosis of lung cancer is mostly due to too late detection of early lung cancer, which may be treated with good success. Therefore, different diagnostic methods are developing for more efficient detection of early lung cancer: besides modern radiological, bronchoscopic methods with additional fluorescence techniques, quantitative cytological investigations, also histological and molecular investigations are included. Histology may reveal early preinvasive lung cancer lesions, associated early during multistep lung carcinogenesis with molecular genetic changes. Patients and methods. Preinvasive epithelial lung cancer lesions we searched in two groups of patients. In the first group of 316 patients from the period March 2003 - August 2006, 498 bronchial and transbronchial biopsies were examined for squamous metaplasia and dysplasia, carcinoma in situ, and invasive tumours. In the second group of 238 patients from the period January 2004 - August 2006, resected primary lung tumours were analysed for preinvasive and invasive neuroendocrine tumours and atypical adenomatous hyperplasia. Results. The most frequent changes in bronchial and transbronchial biopsies were squamous metaplasia (46.5%), simple or goblet cell hyperplasia of the bronchial epithelium (44.3%), malignant tumours (20.66%) and squamous dysplasia (16.1%), but rare carcinoma in situ (0.63%). Diffuse idiopathic pulmonary neuroendocrine cell hyperplasia was found in 15 (6.3%) cases in the vicinity of 238 resected lung cancer specimens, carcinoid in 12 patients (5%), and mostly combined large cell neuroendocrine cancer in 21 patients (8.8%). Atypical adenomatous hyperplasia was found in 2 patients. Conclusions. Classical histological analysis should be focused on detection of early preinvasive epithelial lung cancer lesions. Additional available molecular investigations may reveal gradual genetic changes characteristic for a series of the preinvasive epithelial histological changes

  9. Improved focal liver lesion detection by increasing flip angle during gadoxetic acid-enhancement in MRI

    International Nuclear Information System (INIS)

    Lee, Se Jy; Kim, Young Keun

    2015-01-01

    To study the differences of focal liver lesion image detection at 3 minute, 10 minute and 15 minute time points on gadoxetic acid (GA)’s enhanced MR imaging with a flip angle (FA) of 30° compared with a 11°. The subjects were 69 patients evaluated with GA enhanced MR imaging with 3.0T MR scanner. The patients are total 35(23 men and 7 women at the mean age of 60.4 years), hepatocellular carcinoma(23) and metastsis(12) except for normal, cyst and hemangioma. After GA was injected, FA 11° and 30° images were obtained at 3 minute, 10 minute and 15 minute time points respectively. After quantitative and qualitative assessment of each image was done, statistical analysis was performed by using the independent sample T-test. From both quantitative and qualitative assessment of 3 minute and 10 minute MR images after the injection of GA, FA 30° images was found to be superior than FA 11°, but there were no statistical significance. However, at 15 minute time point, Statistically significant FA 30° image(p<0.05) was better than FA 11° therefore, the FA 30° improves the focal liver lesion detection. FA 30° of MR image can detect liver lesion more sensitively than the existing FA11° image after GA contrast enhancement at 15 minute time point

  10. Computerized detection of breast lesions in multi-centre and multi-instrument DCE-MR data using 3D principal component maps and template matching

    Science.gov (United States)

    Ertas, Gokhan; Doran, Simon; Leach, Martin O.

    2011-12-01

    In this study, we introduce a novel, robust and accurate computerized algorithm based on volumetric principal component maps and template matching that facilitates lesion detection on dynamic contrast-enhanced MR. The study dataset comprises 24 204 contrast-enhanced breast MR images corresponding to 4034 axial slices from 47 women in the UK multi-centre study of MRI screening for breast cancer and categorized as high risk. The scans analysed here were performed on six different models of scanner from three commercial vendors, sited in 13 clinics around the UK. 1952 slices from this dataset, containing 15 benign and 13 malignant lesions, were used for training. The remaining 2082 slices, with 14 benign and 12 malignant lesions, were used for test purposes. To prevent false positives being detected from other tissues and regions of the body, breast volumes are segmented from pre-contrast images using a fast semi-automated algorithm. Principal component analysis is applied to the centred intensity vectors formed from the dynamic contrast-enhanced T1-weighted images of the segmented breasts, followed by automatic thresholding to eliminate fatty tissues and slowly enhancing normal parenchyma and a convolution and filtering process to minimize artefacts from moderately enhanced normal parenchyma and blood vessels. Finally, suspicious lesions are identified through a volumetric sixfold neighbourhood connectivity search and calculation of two morphological features: volume and volumetric eccentricity, to exclude highly enhanced blood vessels, nipples and normal parenchyma and to localize lesions. This provides satisfactory lesion localization. For a detection sensitivity of 100%, the overall false-positive detection rate of the system is 1.02/lesion, 1.17/case and 0.08/slice, comparing favourably with previous studies. This approach may facilitate detection of lesions in multi-centre and multi-instrument dynamic contrast-enhanced breast MR data.

  11. Limits on surface gravities of Kepler planet-candidate host stars from non-detection of solar-like oscillations

    Energy Technology Data Exchange (ETDEWEB)

    Campante, T. L.; Chaplin, W. J.; Handberg, R.; Miglio, A.; Davies, G. R.; Elsworth, Y. P. [School of Physics and Astronomy, University of Birmingham, Edgbaston, Birmingham B15 2TT (United Kingdom); Lund, M. N.; Arentoft, T.; Christensen-Dalsgaard, J.; Karoff, C.; Kjeldsen, H.; Lundkvist, M. [Stellar Astrophysics Centre (SAC), Department of Physics and Astronomy, Aarhus University, Ny Munkegade 120, DK-8000 Aarhus C (Denmark); Huber, D. [NASA Ames Research Center, MS 244-30, Moffett Field, CA 94035 (United States); Hekker, S. [Astronomical Institute, " Anton Pannekoek," University of Amsterdam, Amsterdam (Netherlands); García, R. A. [Laboratoire AIM, CEA/DSM-CNRS-Université Paris Diderot (France); IRFU/SAp, Centre de Saclay, F-91191 Gif-sur-Yvette Cedex (France); Corsaro, E. [Instituut voor Sterrenkunde, KU Leuven, Celestijnenlaan 200D, B-3001 Leuven (Belgium); Basu, S. [Department of Astronomy, Yale University, New Haven, CT 06520 (United States); Bedding, T. R. [Sydney Institute for Astronomy, School of Physics, University of Sydney, Sydney (Australia); Gilliland, R. L. [Center for Exoplanets and Habitable Worlds, The Pennsylvania State University, University Park, PA 16802 (United States); Kawaler, S. D., E-mail: campante@bison.ph.bham.ac.uk [Department of Physics and Astronomy, Iowa State University, Ames, IA 50011 (United States); and others

    2014-03-10

    We present a novel method for estimating lower-limit surface gravities (log g) of Kepler targets whose data do not allow the detection of solar-like oscillations. The method is tested using an ensemble of solar-type stars observed in the context of the Kepler Asteroseismic Science Consortium. We then proceed to estimate lower-limit log g for a cohort of Kepler solar-type planet-candidate host stars with no detected oscillations. Limits on fundamental stellar properties, as provided by this work, are likely to be useful in the characterization of the corresponding candidate planetary systems. Furthermore, an important byproduct of the current work is the confirmation that amplitudes of solar-like oscillations are suppressed in stars with increased levels of surface magnetic activity.

  12. Management of breast lesions detectable only on MRI; Abklaerung ausschliesslich MRT-detektierbarer Mammalaesionen

    Energy Technology Data Exchange (ETDEWEB)

    Siegmann-Luz, K.C.; Bahrs, S.D.; Preibsch, H.; Hattermann, V.; Claussen, C.D. [Universitaetsklinikum Tuebingen (Germany). Abt. Diagnostische und Interventionelle Radiologie

    2014-01-15

    Breast MR imaging has become established as the most sensitive imaging method for diagnosing breast cancer. As a result of the increasing examination volume and improved image quality, the number of breast lesions detected only on MRI and requiring further clarification has risen in recent years. According to the S3-guideline 'Diagnosis, Therapy, and Follow-Up of Breast Cancer' as revised in July 2012, institutions performing breast MRI should provide the option of an MRI-guided intervention for clarification. This review describes the indications, methods and results of MRI-guided interventions for the clarification of breast lesions only visible on MRI. Recent guidelines and study results are also addressed and alternative methods and pitfalls are presented. (orig.)

  13. Harmonizing FDG PET quantification while maintaining optimal lesion detection: prospective multicentre validation in 517 oncology patients

    International Nuclear Information System (INIS)

    Quak, Elske; Le Roux, Pierre-Yves; Robin, Philippe; Bourhis, David; Salaun, Pierre-Yves; Hofman, Michael S.; Callahan, Jason; Binns, David; Hicks, Rodney J.; Desmonts, Cedric; Aide, Nicolas

    2015-01-01

    Point-spread function (PSF) or PSF + time-of-flight (TOF) reconstruction may improve lesion detection in oncologic PET, but can alter quantitation resulting in variable standardized uptake values (SUVs) between different PET systems. This study aims to validate a proprietary software tool (EQ.PET) to harmonize SUVs across different PET systems independent of the reconstruction algorithm used. NEMA NU2 phantom data were used to calculate the appropriate filter for each PSF or PSF+TOF reconstruction from three different PET systems, in order to obtain EANM compliant recovery coefficients. PET data from 517 oncology patients were reconstructed with a PSF or PSF+TOF reconstruction for optimal tumour detection and an ordered subset expectation maximization (OSEM3D) reconstruction known to fulfil EANM guidelines. Post-reconstruction, the proprietary filter was applied to the PSF or PSF+TOF data (PSF EQ or PSF+TOF EQ ). SUVs for PSF or PSF+TOF and PSF EQ or PSF+TOF EQ were compared to SUVs for the OSEM3D reconstruction. The impact of potential confounders on the EQ.PET methodology including lesion and patient characteristics was studied, as was the adherence to imaging guidelines. For the 1380 tumour lesions studied, Bland-Altman analysis showed a mean ratio between PSF or PSF+TOF and OSEM3D of 1.46 (95 %CI: 0.86-2.06) and 1.23 (95 %CI: 0.95-1.51) for SUV max and SUV peak , respectively. Application of the proprietary filter improved these ratios to 1.02 (95 %CI: 0.88-1.16) and 1.04 (95 %CI: 0.92-1.17) for SUV max and SUV peak , respectively. The influence of the different confounding factors studied (lesion size, location, radial offset and patient's BMI) was less than 5 %. Adherence to the European Association of Nuclear Medicine (EANM) guidelines for tumour imaging was good. These data indicate that it is not necessary to sacrifice the superior lesion detection and image quality achieved by newer reconstruction techniques in the quest for harmonizing quantitative

  14. Lesion activity assessment

    DEFF Research Database (Denmark)

    Ekstrand, K R; Zero, D T; Martignon, S

    2009-01-01

    in response to cariogenic plaque as well as lesion arrest. Based on this understanding, different clinical scoring systems have been developed to assess the severity/depth and activity of lesions. A recent system has been devised by the International Caries Detection and Assessment System Committee...

  15. La ciclooxigenasa-2 (COX-2 y el factor de crecimiento epidérmico (EFG en lesiones epiteliales orales premalignas Cyclooxygenase-2 (COX-2 and epidermal growth factor (EGF in oral premalignant epithelial lesions

    Directory of Open Access Journals (Sweden)

    S. Díaz Prado

    2009-06-01

    Full Text Available Las lesiones premalignas orales incluyen eritroplasias (manchas rojas y leucoplasias (manchas blancas, las cuales se desarrollan a lo largo de superficies epiteliales. Estas lesiones son considerados marcadores en la "carcinogénesis de campo" ya que pacientes con lesiones premalignas orales pueden desarrollar carcinoma de células escamosas (CCS en el sitio de las lesiones, así como en otros lugares de tracto aerodigestivo superior. Se está haciendo un gran esfuerzo para identificar nuevos biomarcadores SEBs (surrogate endpoint biomarkers para el carcinoma de células escamosas de cabeza y cuello. Los SEBs candidatos para el carcinoma de células escamosas invasivo en el trato aerodigestivo superior deben ser detectables con los cambios moleculares celulares y tisulares que tienen lugar durante la formación del tumor. Entre los diferentes marcadores que se han propuesto hasta la actualidad, la ciclooxigenasa- 2 (COX-2 y el receptor del factor de crecimiento epidérmico (EGFR parecen ser los más prometedores. COX-2 se sobre expresa durante el proceso tumoral, desde hiperplasia temprana a enfermedad metastásica. EGFR también está anormalmente activado en tumores epiteliales, pues las células de casi todas estas neoplasias expresan altos niveles de este receptor, una característica asociada con un peor pronóstico clínico. En este sentido el tracto aerodigestivo superior proporciona un sistema o modelo único para el estudio de CCS y para la investigación de nuevos candidatos SEBs.Oral premalignant lesions include leukoplakia (white patch and erythroplakia (red patch, which develop on epithelial surfaces. These lesions are markers for field cancerization because patients with oral premalignancy can develop squamous cell carcinoma at the site of the lesion(s and at other sites in the upper aerodigestive tract. An effort is being made to identify surrogate endpoint biomarkers (SEBs for head and neck squamous cell carcinoma (HNSCC

  16. Detection and excision of non-palpable breast lesions by radio guided surgery and air injection for radiological control

    International Nuclear Information System (INIS)

    Machado, Rafael Henrique Szymanski; Gutfilen, Bianca; Fonseca, Lea Mirian Barbosa da

    2005-01-01

    Purpose: to asses the efficiency of the radioguided localization and removal of occult breast lesions using radiopharmaceuticals injected directly into the lesions or close to them with posterior air injection as a radiological control. Methods: twenty-nine consecutive patients with thirty-two occult breast lesions detected mammographically or by ultrasound, and categorized 3, 4 and 5 BI-RADS, were included in this observational study with results expressed in percentages. The radiopharmaceutical used was human serum albumin labeled with 99m Tc-HSA injected inside or close to the lesion using mammographic or ultrasonographic guidance. The injection of the radiopharmaceutical was followed immediately by air injection through the needle used for stereotaxis as a radiological control of the radiopharmaceutical placement. The excision biopsy was carried out with the aid of a hand-held gamma-detecting probe and the entire removal of the lesion was verified by X-ray of the surgical specimens or by intraoperative frozen section examination. Results: breast cancer was found in 10.0% (1/10) of the 3 BI-RADS lesions, in 31.5% (6/19) of the 4 BI-RADS and in 66.6% (2/3) of the 5 BI-RADS. The radiotracer was correctly positioned in 96.8% of the specimens (31/32) allowing the removal of also 96.8% of the studied non-palpable breast lesions. To show the entire removal, X-ray was used in 23 cases (71.8%), intraoperative frozen section study in 21.8% (7/32) and both methods in 6.2% (2/32). Conclusions: radioguided surgery showed to be an important tool in the removal of non-palpable breast lesions, as a simple, fast and feasible method that can be implemented in the clinical routine of these patients. (author)

  17. Proliferative changes in nonpalpable breast lesions detected by mammography; Alteraciones profiferativas de la mama en lesiones no palpables detectadas por mamografia

    Energy Technology Data Exchange (ETDEWEB)

    Vega, A.; Delgado, A.; Ortega, E.; Garijo, F. [Hospital Universitario Marques de Valdecilla. Santander (Spain); Mosquera, J.; Sogo, C.; Alvarez, A. [Complejo Hospitalario Juan Canalejo. La Coruna (Spain)

    2000-07-01

    To analyze retrospectively the radiological findings in nonpalpable breast lesions detected by mammography that lead to the performance of surgical biopsy, resulting in a histological diagnosis of proliferative breast disease with and without atypia. From two Spanish hospitals, 421 women with 429 biopsies indicative of the presence of proliferative breast disease with and without atypia were selected out of a total of 1252 surgical biopsies in nonpalpable lesions that proved to be benign. Age, personal and familial history of breast cancer, reason for requesting the mammography and radiological findings that had indicated the need for surgical biopsy were recorded for each patient. The diagnosis was proliferative breast disease (epithelial hyperplasia) in 347 women with 354 biopsies and atypical hyperplasia in the remaining 74 women with 75 biopsies, representing 28% and 6%, respectively, of the 1252 biopsies of lesions found to be benign. In 221 of the 354 cases of epithelial hyperplasia (62%) and 45 of the 75 cases of atypical hyperplasia (60%), the presence of calcifications was the most common radiological findings leading to biopsy (p<0.05). Parenchymal distortion, with or without calcifications, was the second most common radiological sign. The histological study revealed a close relationship between these proliferative events and radial scars. Calcifications are the radiological finding that most frequently indicate the need for surgical biopsy in nonpalpable lesions that results in a diagnosis of proliferative breast disease with and without atypia. (Author) 12 refs.

  18. Additional lesions detected in therapeutic scans with 177Lu-DOTATATE reflect higher affinity of 177Lu-DOTATATE for somatostatin receptors.

    Science.gov (United States)

    Mirzaei, Siroos; Bastati, Brigitte; Lipp, Rainer W; Knoll, Peter; Zojer, Niklas; Ludwig, Heinz

    2011-01-01

    Peptide receptor-targeted radionuclide therapy (PRRT) of somatostatin receptor (SR)-expressing neuroendocrine tumors (NETs) has become an established therapeutic option in patients with advanced NETs. The aim of this study was to compare the lesion detection rate of (99m)Tc-EDDA/HYNIC-TOC, a newly developed tracer for NET imaging, with (177)Lu-DOTATATE used for PRRT. 8 patients (4 women, 4 men, age range 46-76 years) with histologically proven NETs, who showed high SR loads by (99m)Tc-EDDA/HYNIC-TOC scintigraphy, were treated with (177)Lu-DOTATATE. After treatment, all patients were subjected to whole-body scintigraphy with additional low-dose single-photon emission computed tomography (SPECT-CT) of the chest and abdomen. All patients demonstrated (177)Lu-DOTATATE accumulation in all lesions previously detected by (99m)Tc- EDDA/HYNIC-TOC scintigraphy. Three patients showed additional lesions in the liver and lungs. SPECT-CT after (177)Lu-DOTATATE therapy may be helpful in detecting additional lesions not seen using (99m)Tc-EDDA/HYNIC-TOC. This could reflect the broader affinity of (177)Lu-DOTATATE for SRs compared with (99m)Tc-EDDA/HYNIC-TOC. Copyright © 2011 S. Karger AG, Basel.

  19. Incremento de la detección de lesiones cervicales mediante inspección visual. Puerto Esperanza. 2008 Detection Increase of cervix lesions by means of visual examination in Puerto Esperanza, 2008

    Directory of Open Access Journals (Sweden)

    José G Sanabria Negrín

    2011-09-01

    Full Text Available Las pruebas visuales del cuello uterino mediante ácido acético al 4-5 % (IVA y Lugol (IVSL contribuyen a detectar lesiones. Este constituye el primer reporte de su uso en Cuba. Objetivo: demostrar el incremento de la detección de lesiones cervicales premalignas y malignas mediante el uso de pruebas visuales en la APS. Método: estudio de casos-controles en Puerto Esperanza, Viñales, 2008. Universo: Mujeres de 15-64 años con relaciones sexuales penetrantes. Muestra: Mujeres con pruebas visuales y citología alterada (n1= 18 casos o no (n2= 178 controles. En Patología de Cuello se les practicó colposcopia y biopsia dirigida o por conización con asa diatérmica. Se calcularon frecuencias absolutas y relativas porcentuales y la probabilidad de detectar lesiones por las pruebas aisladas o en conjunto, además de las pruebas de rendimiento diagnóstico. Resultados: IVA e IVSL resultaron positivas en 92.9% y 79.6%, respectivamente. La probabilidad conjunta de tener lesiones fue 0.7395. Con citología alterada el 88.9 % tenía IVA+ y 77,9 % tuvo IVSL+. La colposcopia resultó positiva en el 70.9 % y la probabilidad de tener una lesión mediante pruebas visuales y la colposcopia fue 0.516. De las 136 mujeres biopsiadas resultaron útiles el 99.3%, de las cuales casi el 50 % tuvo lesiones premalignas/malignas. Las pruebas de rendimiento fueron superiores para la IVA y la IVSL que para la citología. No se detectó cáncer invasor, pero sí carcinomas in situ. Conclusión: las pruebas visuales aumentaron la cantidad de diagnósticos en 4 veces y debe generalizarse su uso.Visual examination of cervix using acetic acid up to 4-5% (VIA and Lugol's solution (VILI contribute to detect lesions. This constitutes the first report of their use in Cuba. Objective: to demonstrate the detection increase of pre-malignant and malignant cervical lesions by means of visual examination in Primary Health Care. Method: control-case studies in Puerto Esperanza, Vi

  20. Coordinating Center: Molecular and Cellular Findings of Screen-Detected Lesions | Division of Cancer Prevention

    Science.gov (United States)

    The Molecular and Cellular Characterization of Screen‐Detected Lesions ‐ Coordinating Center and Data Management Group will provide support for the participating studies responding to RFA CA14‐10. The coordinating center supports three main domains: network coordination, statistical support and computational analysis and protocol development and database support. Support for

  1. A Novel Fuzzy Topological Approach to the Detection of Mammographic Lesions and Quantification of Parenchymal Density

    National Research Council Canada - National Science Library

    Udupa, Jayaram

    2001-01-01

    .... During this project period, the following have been accomplished: The development and validation of a new method of lesion and density detection based on fuzzy connectedness that utilizes the relative strength of connectedness among objects...

  2. Improved assessment of multiple sclerosis lesion segmentation agreement via detection and outline error estimates

    Directory of Open Access Journals (Sweden)

    Wack David S

    2012-07-01

    Full Text Available Abstract Background Presented is the method “Detection and Outline Error Estimates” (DOEE for assessing rater agreement in the delineation of multiple sclerosis (MS lesions. The DOEE method divides operator or rater assessment into two parts: 1 Detection Error (DE -- rater agreement in detecting the same regions to mark, and 2 Outline Error (OE -- agreement of the raters in outlining of the same lesion. Methods DE, OE and Similarity Index (SI values were calculated for two raters tested on a set of 17 fluid-attenuated inversion-recovery (FLAIR images of patients with MS. DE, OE, and SI values were tested for dependence with mean total area (MTA of the raters' Region of Interests (ROIs. Results When correlated with MTA, neither DE (ρ = .056, p=.83 nor the ratio of OE to MTA (ρ = .23, p=.37, referred to as Outline Error Rate (OER, exhibited significant correlation. In contrast, SI is found to be strongly correlated with MTA (ρ = .75, p  Conclusions The DE and OER indices are proposed as a better method than SI for comparing rater agreement of ROIs, which also provide specific information for raters to improve their agreement.

  3. The spatial resolution of the porcine multifocal electroretinogram for detection of laser-induced retinal lesions

    DEFF Research Database (Denmark)

    Kyhn, Maria Voss; Kiilgaard, Jens Folke; Scherfig, Erik

    2008-01-01

    This study aimed to investigate the spatial resolution of a porcine multifocal electroretinogram (mfERG) protocol by testing its ability to detect laser-induced retinal lesions. Furthermore, we wanted to describe time-dependent changes in implicit time and amplitude of the different mfERG peaks...

  4. Rapid noninvasive detection of experimental atherosclerotic lesions with novel 99mTc-labeled diadenosine tetraphosphates

    Science.gov (United States)

    Elmaleh, David R.; Narula, Jagat; Babich, John W.; Petrov, Artiom; Fischman, Alan J.; Khaw, Ban-An; Rapaport, Eliezer; Zamecnik, Paul C.

    1998-01-01

    The development of a noninvasive imaging procedure for identifying atherosclerotic lesions is extremely important for the clinical management of patients with coronary artery and peripheral vascular disease. Although numerous radiopharmaceuticals have been proposed for this purpose, none has demonstrated the diagnostic accuracy required to replace invasive angiography. In this report, we used the radiolabeled purine analog, 99mTc diadenosine tetraphosphate (Ap4A; AppppA, P1,P4-di(adenosine-5′)-tetraphosphate) and its analogue 99mTc AppCHClppA for imaging experimental atherosclerotic lesions in New Zealand White rabbits. Serial gamma camera images were obtained after intravenous injection of the radiolabeled dinucleotides. After acquiring the final images, the animals were sacrificed, ex vivo images of the aortas were recorded, and biodistribution was measured. 99mTc-Ap4A and 99mTc AppCHClppA accumulated rapidly in atherosclerotic abdominal aorta, and lesions were clearly visible within 30 min after injection in all animals that were studied. Both radiopharmaceuticals were retained in the lesions for 3 hr, and the peak lesion to normal vessel ratio was 7.4 to 1. Neither of the purine analogs showed significant accumulation in the abdominal aorta of normal (control) rabbits. The excised aortas showed lesion patterns that were highly correlated with the in vivo and ex vivo imaging results. The present study demonstrates that purine receptors are up-regulated in experimental atherosclerotic lesions and 99mTc-labeled purine analogs have potential for rapid noninvasive detection of plaque formation. PMID:9435254

  5. Detection and classification of focal liver lesions in patients with colorectal cancer: Retrospective comparison of diffusion-weighted MR imaging and multi-slice CT

    International Nuclear Information System (INIS)

    Eiber, Matthias; Fingerle, Alexander A.; Brügel, Melanie; Gaa, Jochen; Rummeny, Ernst J.; Holzapfel, Konstantin

    2012-01-01

    Objectives: To compare the diagnostic performance of diffusion-weighted MR imaging (DWI) with multi-slice CT (MS-CT) in the detection and classification of focal liver lesions in patients with colorectal cancer. Methods: In a retrospective study 68 patients who underwent DWI at 1.5 T (b-values of 50, 300 and 600 s/mm 2 ) and contrast-enhanced MS-CT were analysed by two radiologists blinded to the clinical results. Imaging results were correlated with intraoperative surgical and ultrasound findings (n = 24), imaging follow-up or PET (n = 44). Sensitivity of DWI and MS-CT in detection of focal liver lesions was compared on a per-lesion and a per-segment basis. Receiver operator-characteristic (ROC) curves to determine the diagnostic performance and the sensitivities of correctly identifying liver metastases on a segmental base were calculated. Results: For lesion detection, DWI was significantly superior to MS-CT both on a per-lesion (difference in sensitivities for reader 1 and 2 22.65% and 19.06%, p < 0.0001) and a per-segment basis (16.86% and 11.76%, p < 0.0001). Especially lesions smaller than 10 mm were better detected with DWI compared to MS-CT (difference 41.10% and 29.45%, p < 0.0001). ROC-analysis showed superiority for lesions classification (p < 0.0001) of DWI (AUC: 0.949 and 0.951) as compared to MS-CT (AUC: 0.879 and 0.892, p < 0.0001 and p = 0.005). DWI was able to filter out metastatic segments with a higher sensitivity (88.2 and 86.5%) compared to MS-CT (68.0 and 67.4%, p < 0.0001 and p = 0.005, respectively). Conclusion: Compared to MS-CT DWI is both more sensitive in the detection of liver lesions and more accurate in determining the extent of metastatic disease in patients with colorectal cancer and therefore might help to optimize therapeutic management in those patients.

  6. Improved detection reveals active β-papillomavirus infection in skin lesions from kidney transplant recipients.

    Science.gov (United States)

    Borgogna, Cinzia; Lanfredini, Simone; Peretti, Alberto; De Andrea, Marco; Zavattaro, Elisa; Colombo, Enrico; Quaglia, Marco; Boldorini, Renzo; Miglio, Umberto; Doorbar, John; Bavinck, Jan N Bouwes; Quint, Koen D; de Koning, Maurits N C; Landolfo, Santo; Gariglio, Marisa

    2014-08-01

    The aim of this study was to determine whether detection of β-HPV gene products, as defined in epidermodysplasia verruciformis skin cancer, could also be observed in lesions from kidney transplant recipients alongside the viral DNA. A total of 111 samples, corresponding to 79 skin lesions abscised from 17 kidney transplant recipients, have been analyzed. The initial PCR analysis demonstrated that β-HPV-DNA was highly present in our tumor series (85%). Using a combination of antibodies raised against the E4 and L1 proteins of the β-genotypes, we were able to visualize productive infection in 4 out of 19 actinic keratoses, and in the pathological borders of 1 out of 14 squamous cell carcinomas and 1 out of 31 basal cell carcinomas. Increased expression of the cellular proliferation marker minichromosome maintenance protein 7 (MCM7), that extended into the upper epithelial layers, was a common feature of all the E4-positive areas, indicating that cells were driven into the cell cycle in areas of productive viral infections. Although the present study does not directly demonstrate a causal role of these viruses, the detection of E4 and L1 positivity in actinic keratosis and the adjacent pathological epithelium of skin cancer, clearly shows that β-HPV are actively replicating in the intraepidermal precursor lesions of kidney transplant recipients and can therefore cooperate with other carcinogenic agents, such as UVB, favoring skin cancer promotion.

  7. Virtual gastroscopy using spiral CT in gastric lesions

    International Nuclear Information System (INIS)

    Shin, Sang Soo; Kang, Heoung Keun; Jeong, Yong Yeon; Yoon, Man Won; Song, Sang Gook; Jeong, Gwang Woo

    1998-01-01

    To compare virtual gastroscopy using spiral CT with conventional endoscopy for the detection and evaluation of gastric lesions. During a previous six-month period, 30 patients with pathologically-proven gastric lesions underwent conventional endoscopy and virtual gastroscopy using spiral CT. There were 18 cases of advanced gastric carcinoma, eight benign ulcers, and four submucosal tumors(two leiomyomas, two lymphomas). Source images of virtual gastroscopy were three-dim-ensionally reconstructed within an Advantage Windows Workstation and virtual gastroscopic images were obtained using Navigator Software. On analysis, images were graded according to their quality(excellent, good, poor). Virtual gastroscopic images were interpreted by two radiologists blinded to conventional endoscopic findings, and were subsequently compared with endoscopic findings in terms of detectability and findings. In the cases of advanced gastric carcinoma, lesions were classified according to Borrmann's system. For virtual gastroscopy, overall image quality was excellent in 21 cases(70%), good in five(17%), and poor in four(13%). Lesions were detected in 25 cases(83%). Among the 18 advanced gastric carcinomas, virtual gastroscopy image quality was excellent in 14 cases(78%), good in two(11%), and poor in two(11%). Lesions were detected in 16 cases(89%). Two Borrmann type IV cases were not detected. Among the eight benign ulcers, virtual gastroscopy image quality was excellent in three cases(38%), good in three(38%), and poor in two(25%). The detection of lesion was possible in five cases(63%). In all submucosal tumors, virtual gastroscopy image quality was excellent. Lesions were detected in all cases. Virtual gastroscopy using spiral CT is safe and noninvasive, and for the evaluation of gastric lesions may be complementary to axial CT. It successfully detects gastric lesions, and in depicting the pattern of gastric folds its image quality is excellent.=20

  8. MRI screening-detected breast lesions in high-risk young women: the value of targeted second-look ultrasound and imaging-guided biopsy.

    Science.gov (United States)

    Peter, P; Dhillon, R; Bose, S; Bourke, A

    2016-10-01

    To analyse the value of targeted second-look ultrasound and imaging-guided biopsy in high-risk young women eligible for screening magnetic resonance imaging (MRI) in a tertiary referral centre in Perth, Western Australia. A retrospective analysis of eligible high-risk young women who underwent screening breast MRI and targeted second-look ultrasound between June 2012 and June 2014 was performed with review of data. Over a 2-year period, 139 women underwent high-risk screening MRI. Of these, 30 women (with a total of 45 lesions) were recalled for targeted second-look ultrasound. Thirty-four MRI-detected lesions were identified on targeted ultrasound with 19 of them proceeding to ultrasound-guided biopsy, while the remaining 15 lesions were considered benign on ultrasound, were not biopsied, and were stable on follow-up imaging 12 months later. One lesion proceeded to an MRI-guided biopsy to confirm a benign result. Of the 11 lesions not seen on ultrasound, nine underwent MRI biopsy, one proceeded directly to hook wire localisation and excision, and one did not return for biopsy and was lost to follow-up. The overall biopsy rate was 14.4%. The cancer detection rate was 1.4%. The results of this study indicate that targeted second-look ultrasound and ultrasound-guided biopsy is a cost-effective and time-efficient approach for MRI-detected lesions in young women at high risk of developing breast cancer. MRI-guided biopsy should be considered for ultrasonographically occult suspicious lesions as there is a low, but definite, risk of cancer. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  9. OCT investigation of dental lesions

    Science.gov (United States)

    Osiac, Eugen; Popescu, Sanda Mihaela; Scrieciu, Monica; Mercuţ, Rǎzvan; Mercuţ, Veronica; Vǎtu, Mihaela

    2018-03-01

    There are several important non carious lesions affecting the tooth structure, lesions which may be classified into four clinical forms of dental wear: abfraction, erosion, attrition and abrasion, and different types of root resorption. Search for new, non-invasive and fast methods able to detect and describe such injuries is of utmost importance. Optical coherence tomography (OCT) proved itself as an appropriate investigation method for several medical fields including ophthalmology, dermatology, cardiology etc. Our study reveals OCT preliminary investigations as a promising tool for detecting and evaluating of the mentioned lesions.

  10. Detection of fat in focal liver lesions using chemical-shift MR imaging: its significance in patients with and without hepatic cirrhosis

    International Nuclear Information System (INIS)

    Martin, J.

    1999-01-01

    To determine the utility of the chemical shift technique in MRI for the detection of fact in focal hepatic lesions and to see its significance in patients with and without hepatic cirrhosis. 159 patients with 207 hepatic lesions were studied using MRI (IT). Two groups were established: a) patients with hepatic cirrhosis (n=63 with 69 lesions) and b) patients without cirrhosis (n=96 with 138 lesions). Images were obtained in phase (P) and in opposite phase (OP) with gradient echo sequences (RG). The parameter used to differentiate the lesions with fat from those without fat was the variation percentage of the intensity of the signal (VIS) between the images in P and in OP. The statistical valuation was carried out using Student's t tests and the area under the ROC curve. The chemical shift technique detected fat in 25 lesions (12%), 10 hepatocarcinomas in the patients with cirrhosis and two angiomyolipomas and 13 nodular fat infiltrations in the patients who did not have cirrhosis. The average VIS percentage in the 10 hepatocarcinomas was 174.77% (ranging from 88.64% to 369.33%) while in the remaining 59 hepatocarcinomas it was -4.03% (ranging from 12.79% to -19.10%) (p=0.003). In the patients who did not have cirrhosis the average VIS percentage of the lesions with fat was 161.23 (ranging from 19.82 to 605.78) while in the lesions without fat it was -0.41 (ranging from -18.96 to 19.52) (p=0.003). The area under the ROC curve was 1 for the VIS parameter. The chemical shift technique allowed for fat to be detected within hepatic lesions. Based on our study, a nodule with fat in a patient with hepatic cirrhosis is suspected to have hepatocarcinomas while in patients who do not suffer from cirrhosis the existence of fat in a nodule favours its bening nature. (Author) 39 refs

  11. Claudin-4-targeted optical imaging detects pancreatic cancer and its precursor lesions.

    Science.gov (United States)

    Neesse, Albrecht; Hahnenkamp, Anke; Griesmann, Heidi; Buchholz, Malte; Hahn, Stefan A; Maghnouj, Abdelouahid; Fendrich, Volker; Ring, Janine; Sipos, Bence; Tuveson, David A; Bremer, Christoph; Gress, Thomas M; Michl, Patrick

    2013-07-01

    Novel imaging methods based on specific molecular targets to detect both established neoplasms and their precursor lesions are highly desirable in cancer medicine. Previously, we identified claudin-4, an integral constituent of tight junctions, as highly expressed in various gastrointestinal tumours including pancreatic cancer. Here, we investigate the potential of targeting claudin-4 with a naturally occurring ligand to visualise pancreatic cancer and its precursor lesions in vitro and in vivo by near-infrared imaging approaches. A non-toxic C-terminal fragment of the claudin-4 ligand Clostridium perfringens enterotoxin (C-CPE) was labelled with a cyanine dye (Cy5.5). Binding of the optical tracer was analysed on claudin-4 positive and negative cells in vitro, and tumour xenografts in vivo. In addition, two genetically engineered mouse models for pancreatic intraepithelial neoplasia (PanIN) and pancreatic cancer were used for in vivo validation. Optical imaging studies were conducted using 2D planar fluorescence reflectance imaging (FRI) technology and 3D fluorescence-mediated tomography (FMT). In vitro, the peptide-dye conjugate showed high binding affinity to claudin-4 positive CAPAN1 cells, while claudin-4 negative HT1080 cells revealed little or no fluorescence. In vivo, claudin-4 positive tumour xenografts, endogenous pancreatic tumours, hepatic metastases, as well as preinvasive PanIN lesions, were visualised by FRI and FMT up to 48 h after injection showing a significantly higher average of fluorochrome concentration as compared with claudin-4 negative xenografts and normal pancreatic tissue. C-CPE-Cy5.5 combined with novel optical imaging methods enables non-invasive visualisation of claudin-4 positive murine pancreatic tumours and their precursor lesions, representing a promising modality for early diagnostic imaging.

  12. FDG PET/CT Is Superior to Enhanced CT in Detecting Recurrent Subcentimeter Lesions in the Abdominopelvic Cavity in Colorectal Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Hai Jeon; Kim, Yu Kyeong; Kim, Sang Eun [Seoul National Univ. Bundang Hospital, Seoul (Korea, Republic of); Lee, Jong Jin [Asan Medical Center, Univ. of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2011-06-15

    This study aims to compare the performance of contrast enhanced computed tomography (CeCT) and 18 F fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) in detecting small tumor implants and metastatic lymph nodes (LNs) in the abdominopelvic cavity in patients with colorectal cancer. We enrolled 16 patients who were clinically suspected of experiencing a recurrences (6 male, 10 female; mean age 61{+-}14 years). All subjects underwent CeCT and PET/CT, and the performance of these methods was compared with regard to detecting recurrences. The final diagnosis of a recurrence was made clinically. CeCT identified 38 lesions in 12 patients, all of which were detected by PET/CT. PET/CT found 27 additional lesions in 8 patients, comprising 9 seeding nodules (2 in the right upper quadrant of the abdomen and 7 in the pelvic cavity) and 18 LNs (2 celiac, 2 paraaortic, 2 hepatic hilar, 11 common iliac, 1 external iliac). Most additional lesions were located in the pelvic cavity (approximately 78% of seeding nodules that were detected solely by PET/CT was significantly higher compared with the CeCT and PET/CT confirmed nodules (5.5{+-}4.2 vs. 2.9{+-}2.5, p=0.03). The seeding nodules that were detected only by PET/CT were significantly smaller than the CeCT and PET/CT confirmed nodules (long axis:1.0{+-}0.3cm vs. 2.0{+-}1.1cm, p=0.001; short axis: 0.8{+-}0.3cm vs. 1.7{+-}0.9cm, p=0.001). Similarly, PET/CT only detected LNs were significantly smaller than CeCT and PET/CT identified LNs (0.7{+-}0.1cm vs. 2.3{+-}1.2cm, p<0.0001). PET/CT is superior to CeCT in detecting seeding nodules and metastatic LNs in patients with recurrent colorectal cancer. Specifically, PET/CT detects subcentimeter lesions in anatomically deformed pelvic cavities.

  13. Comparison of conventional panoramic radiography and panoramic digital subtraction radiography in detection of simulated lesions of mandibular condyle

    Directory of Open Access Journals (Sweden)

    Panjnoush M.

    2008-12-01

    Full Text Available "n  "nBackground and Aim: Digital subtraction Radiography (DSR is a method of accurate assessing condylar head changes. several studies have been carried out in applying DSR in dentistry, however there is a few number of studies in efficacy of DSR method in assesment of condylar head changes, The aim of this study was to compare panoramic radiography and DSR detecting simulated lesions of the mandibular condyl. "nMaterials and Methods: this was a process reaserch study, in which two dry human skulls with no obvious temporomandibular joint pathology were used. Osteophytic lesions were simulated using three sizes of bone chips that were placed on the medial portion of anterior and superolateral aspects of the condyle. Osteolytic lesions were simulated making 1 and 2 mm holes using round burr in the central portion of anterior aspect and Lateral pole of the condyle. Panoramic radiographs were prepared with and without the lesions in place. These paired radiographs were digitized and digital- subtraction images of the original panoramic images were obtained. Eight observers evaluated 155 images of each modality for the presence or absence and the type of simulated lesions of the mandibular condyle. Sensitivity, specificity, reliability and measure of agreement were analyzed using kappa test and crossed tables and qualitative variables were assess by chi-square and fisher's Exact test. "nResults: Specificity of panoramic and DSR methods were 15.4% and 66.7% respectively. Sensitivity of panoramic and DSR methods were 61.1% and 80.6% for osteophytic lesions and 37.5% and 83.3% for Osteolytic lesions. The percentage of correct decisions made in DSR method was significantly more than conventional panoramic method (82.6% vs 41.9% (p<0.0001. "nConclusion: Based on the results of this study digital subtraction technique was significantly more accurate than the panoramic radiographs in detection of simulated lesions of the mandibular condyle.

  14. mHealth App for Risk Assessment of Pigmented and Nonpigmented Skin Lesions-A Study on Sensitivity and Specificity in Detecting Malignancy.

    Science.gov (United States)

    Thissen, Monique; Udrea, Andreea; Hacking, Michelle; von Braunmuehl, Tanja; Ruzicka, Thomas

    2017-12-01

    With the advent of smartphone devices, an increasing number of mHealth applications that target melanoma identification have been developed, but none addresses the general context of melanoma and nonmelanoma skin cancer identification. In this study a smartphone application using fractal and classical image analysis for the risk assessment of skin lesions is systematically evaluated to determine its sensitivity and specificity in the diagnosis of melanoma and nonmelanoma skin cancer along with actinic keratosis and Bowen's disease. In the Department of Dermatology, Catharina Hospital Eindhoven, The Netherlands, 341 melanocytic and nonmelanocytic lesions were imaged using SkinVision app; 239 underwent histopathological examination, while the rest of 102 lesions were clinically diagnosed as clearly benign and not removed. The algorithm has been calibrated using the images of the first 233 lesions. The calibrated version of the algorithm was used in a subset of 108 lesions, and the obtained results were compared with the medical findings. On the 108 cases used for evaluation the algorithm scored 80% sensitivity and 78% specificity in detecting (pre)malignant conditions. Although less accurate than the dermatologist's clinical eye, the app may offer support to other professionals who are less familiar with differentiating between benign and malignant lesions. An mHealth application for the risk assessment of skin lesions was evaluated. It adds value to diagnosis tools of its type by taking into consideration pigmented and nonpigmented lesions all together and detecting signs of malignancy with high sensitivity.

  15. Value of Fat-Suppressed Proton-Density-Weighted Turbo Spin-Echo Sequences in Detecting Meniscal Lesions: Comparison with Arthroscopy

    International Nuclear Information System (INIS)

    Schaefer, F.K.W.; Schaefer, P.J.; Brossmann, J.; Frahm, C.; Hilgert, R.E.; Heller, M.; Jahnke, T.

    2006-01-01

    Purpose: To evaluate fat-suppressed (FS) proton-density-weighted (PDw) turbo spin-echo (TSE) magnetic resonance imaging (MRI) compared to arthroscopy in the detection of meniscal lesions. Material and Methods: In a prospective study, 31 knee joints were imaged on a 1.5T MR scanner before arthroscopy using the following sequences: (a) coronal and sagittal FS-PDw TSE (TR/TE: 4009/15 ms); (b) coronal T1w SE (TR/TE: 722/20 ms), and sagittal PDw TSE (TR/TE: 3800/15 ms). Other imaging parameters were: slice thickness 3 mm, FOV 160 mm, matrix 256x256. A total of 186 meniscal regions (62 menisci; anterior horn, body, posterior horn) were evaluated. Standard of reference was arthroscopy. Sensitivity, specificity, negative predictive value (npv), positive predictive value (ppv), and accuracy were calculated. Results: Arthroscopically, meniscal lesions were detected in 55/186 segments (35 medial and 20 lateral meniscal lesions). Sensitivity, specificity, npv, ppv, and accuracy for combination of coronal and sagittal FS PDw TSE were 91.4%, 98.3%, 95%, 97%, and 93.5% for the medial meniscus, and 90%, 98.6%, 97.3%, 94.7%, and 96.8% for the lateral. The results were comparable to the combination of coronal T1w SE and sagittal PDw TSE for the medial (88.6%, 98.3%, 93.4%, 96.9%, 91.4%) and the lateral (90%, 95.9%, 97.2%, 85.7%, 92.5%) meniscus. Conclusion: FS PDw TSE-MR sequences are an excellent alternative for the detection of meniscal lesions in comparison with diagnostic arthroscopy

  16. Primary Three-Dimensional Analysis with Perspective-Filet View Versus Primary Two-Dimensional Analysis: Evaluation of Lesion Detection by Inexperienced Readers at Computed Tomographic Colonography in Symptomatic Patients

    International Nuclear Information System (INIS)

    Fisichella, V.A.; Horvath, S.; Hellstroem, M.; Jaederling, F.; Stotzer, P.O.; Kilander, A.

    2009-01-01

    Background: 'Perspective-filet view' is a novel three-dimensional (3D) viewing technique for computed tomography colonography (CTC). Studies with experienced readers have shown a sensitivity for perspective-filet view similar to that of 2D or 3D endoluminal fly-through in detection of colorectal lesions. It is not known whether perspective-filet view, compared to axial images, improves lesion detection by inexperienced readers. Purpose: To compare primary 3D analysis using perspective-filet view (3D Filet) with primary 2D analysis, as used by inexperienced CTC readers. Secondary aims were to compare lesion detection by 3D Filet when used by experienced and inexperienced readers, and to evaluate the effect of combined 3D Filet + 2D analysis. Material and Methods: Fifty symptomatic patients were prospectively enrolled. An experienced reader performed 3D Filet analysis followed by complete 2D analysis (3D Filet + 2D), before colonoscopy with segmental unblinding. Two inexperienced readers (readers 2 and 3), blinded to CTC and colonoscopy findings, retrospectively performed 3D Filet analysis and, after 5 weeks, 2D analysis. True positives =6 mm detected by the inexperienced readers with 3D Filet and/or 2D were combined to obtain 3D Filet + 2D. Results: Colonoscopy revealed 116 lesions: 16 lesions =10 mm, 19 lesions 6-9 mm, and 81 lesions =5 mm. For the experienced reader, sensitivities for lesions =6 mm with 3D Filet and 3D Filet + 2D were 77% and 83%, respectively. For the inexperienced readers, sensitivities for lesions =6 mm with 3D Filet and 2D were 51% and 57% (reader 2) and 40% and 43% (reader 3), respectively. There was no significant difference between 3D Filet and 2D regarding sensitivity and reading time. For lesions =6 mm, 3D Filet + 2D improved the sensitivity of reader 2 to 63% and of reader 3 to 51%. Conclusion: Lesion detection by inexperienced readers using perspective-filet view is comparable to that obtained by 2D. Lesion detection improves by

  17. Association between power law coefficients of the anatomical noise power spectrum and lesion detectability in breast imaging modalities

    Science.gov (United States)

    Chen, Lin; Abbey, Craig K.; Boone, John M.

    2013-03-01

    Previous research has demonstrated that a parameter extracted from a power function fit to the anatomical noise power spectrum, β, may be predictive of breast mass lesion detectability in x-ray based medical images of the breast. In this investigation, the value of β was compared with a number of other more widely used parameters, in order to determine the relationship between β and these other parameters. This study made use of breast CT data sets, acquired on two breast CT systems developed in our laboratory. A total of 185 breast data sets in 183 women were used, and only the unaffected breast was used (where no lesion was suspected). The anatomical noise power spectrum computed from two-dimensional region of interests (ROIs), was fit to a power function (NPS(f) = α f-β), and the exponent parameter (β) was determined using log/log linear regression. Breast density for each of the volume data sets was characterized in previous work. The breast CT data sets analyzed in this study were part of a previous study which evaluated the receiver operating characteristic (ROC) curve performance using simulated spherical lesions and a pre-whitened matched filter computer observer. This ROC information was used to compute the detectability index as well as the sensitivity at 95% specificity. The fractal dimension was computed from the same ROIs which were used for the assessment of β. The value of β was compared to breast density, detectability index, sensitivity, and fractal dimension, and the slope of these relationships was investigated to assess statistical significance from zero slope. A statistically significant non-zero slope was considered to be a positive association in this investigation. All comparisons between β and breast density, detectability index, sensitivity at 95% specificity, and fractal dimension demonstrated statistically significant association with p performance. Specifically, lower values of β were associated with lower breast density

  18. Postoperative quality of life outcome and employment in patients undergoing resection of epileptogenic lesions detected by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Moritake, Kouzo; Akiyama, Yasuhiko; Nagai, Hidemasa; Maruyama, Nobuyuki; Takada, Daikei; Daisu, Mitsuhiro; Nagasako, Noriko; Mikuni, Nobuhiro; Hashimoto, Nobuo

    2009-01-01

    The long-term postoperative improvement of quality of life (QOL) and employment were investigated in patients undergoing resection of epileptogenic lesions detected by magnetic resonance (MR) imaging to identify the associated preoperative factors. Thirty of 47 patients who underwent lesionectomy between 1987-2001 replied to questionnaires. Patients with extratemporal resection outnumbered those with temporal lobe resection. The mean follow-up period was 12.4±3.7 years. An arbitrary score for quantitatively assessing QOL was assigned. The mean increases in QOL score points were significantly higher in the late childhood onset group than those in the early childhood onset group, and were also significantly higher in the temporal resection group and extratemporal resection of non-dysplastic cortical pathology group than in the extratemporal resection of dysplastic cortical pathology group. Postoperative QOL improvement and occupational status of patients depended on the completeness of seizure control. Resection of lesions detected by MR imaging in patients with intractable epilepsy resulted in effective long-term QOL improvement and postoperative occupational status. Favorable outcome was related mainly to the pathology of the epileptogenic lesions, whether the lesion site was temporal or extratemporal, and the completeness of seizure control. (author)

  19. Seven tesla MRI improves detection of focal cortical dysplasia in patients with refractory focal epilepsy

    NARCIS (Netherlands)

    Veersema, Tim J; Ferrier, Cyrille H; van Eijsden, Pieter; Gosselaar, Peter H; Aronica, Eleonora; Visser, Fredy; Zwanenburg, Jaco M; de Kort, Gerard A P; Hendrikse, Jeroen; Luijten, Peter R; Braun, Kees P J

    Objective: The aim of this study is to determine whether the use of 7 tesla (T) MRI in clinical practice leads to higher detection rates of focal cortical dysplasias in possible candidates for epilepsy surgery. Methods: In our center patients are referred for 7 T MRI if lesional focal epilepsy is

  20. Measuring telomere length for the early detection of precursor lesions of esophageal squamous cell carcinoma

    International Nuclear Information System (INIS)

    Lin, Shih-Wen; Wang, Guo-Qing; Wei, Wen-Qiang; Lu, Ning; Taylor, Philip R; Qiao, You-Lin; Dawsey, Sanford M; Abnet, Christian C; Freedman, Neal D; Murphy, Gwen; Risques, Rosana; Prunkard, Donna; Rabinovitch, Peter; Pan, Qin-Jing; Roth, Mark J

    2013-01-01

    Esophageal cancer is the sixth leading cause of cancer death worldwide; current early detection screening tests are inadequate. Esophageal balloon cytology successfully retrieves exfoliated and scraped superficial esophageal epithelial cells, but cytologic reading of these cells has poor sensitivity and specificity for detecting esophageal squamous dysplasia (ESD), the precursor lesion of esophageal squamous cell carcinoma (ESCC). Measuring telomere length, a marker for chromosomal instability, may improve the utility of balloon cytology for detecting ESD and early ESCC. We examined balloon cytology specimens from 89 asymptomatic cases of ESD (37 low-grade and 52 high-grade) and 92 age- and sex-matched normal controls from an esophageal cancer early detection screening study. All subjects also underwent endoscopy and biopsy, and ESD was diagnosed histopathologically. DNA was extracted from the balloon cytology cells, and telomere length was measured by quantitative PCR. A receiver operating characteristic (ROC) curve was plotted for telomere length as a diagnostic marker for high-grade dysplasia. Telomere lengths were comparable among the low- and high-grade dysplasia cases and controls, with means of 0.96, 0.96, and 0.92, respectively. The area under the ROC curve was 0.55 for telomere length as a diagnostic marker for high-grade dysplasia. Further adjustment for subject characteristics, including sex, age, smoking, drinking, hypertension, and body mass index did not improve the use of telomere length as a marker for ESD. Telomere length of esophageal balloon cytology cells was not associated with ESCC precursor lesions. Therefore, telomere length shows little promise as an early detection marker for ESCC in esophageal balloon samples

  1. Developing Potential Candidates of Preclinical Preeclampsia

    Directory of Open Access Journals (Sweden)

    Sandra Founds

    2015-11-01

    Full Text Available The potential for developing molecules of interest in preclinical preeclampsia from candidate genes that were discovered on gene expression microarray analysis has been challenged by limited access to additional first trimester trophoblast and decidual tissues. The question of whether these candidates encode secreted proteins that may be detected in maternal circulation early in pregnancy has been investigated using various proteomic methods. Pilot studies utilizing mass spectrometry based proteomic assays, along with enzyme linked immunosorbent assays (ELISAs, and Western immunoblotting in first trimester samples are reported. The novel targeted mass spectrometry methods led to robust multiple reaction monitoring assays. Despite detection of several candidates in early gestation, challenges persist. Future antibody-based studies may lead to a novel multiplex protein panel for screening or detection to prevent or mitigate preeclampsia.

  2. Comparison between gadolinium-enhanced 2D T1-weighted gradient-echo and spin-echo sequences in the detection of active multiple sclerosis lesions on 3.0T MRI

    Energy Technology Data Exchange (ETDEWEB)

    Aymerich, F.X. [Hospital Universitari Vall d' Hebron, Universitat Autonoma de Barcelona, MR Unit. Department of Radiology (IDI), Barcelona (Spain); Universitat Politecnica de Catalunya - Barcelona Tech (UPC), Department of Automatic Control (ESAII), Barcelona (Spain); Auger, C.; Alcaide-Leon, P.; Pareto, D.; Huerga, E.; Corral, J.F.; Mitjana, R.; Rovira, A. [Hospital Universitari Vall d' Hebron, Universitat Autonoma de Barcelona, MR Unit. Department of Radiology (IDI), Barcelona (Spain); Sastre-Garriga, J.; Montalban, X. [Hospital Universitari Vall d' Hebron, Universitat Autonoma de Barcelona, Centre d' Esclerosi Multiple de Catalunya (Cemcat), Department of Neurology/Neuroimmunology, Barcelona (Spain)

    2017-04-15

    To compare the sensitivity of enhancing multiple sclerosis (MS) lesions in gadolinium-enhanced 2D T1-weighted gradient-echo (GRE) and spin-echo (SE) sequences, and to assess the influence of visual conspicuity and laterality on detection of these lesions. One hundred MS patients underwent 3.0T brain MRI including gadolinium-enhanced 2D T1-weighted GRE and SE sequences. The two sets of contrast-enhanced scans were evaluated in random fashion by three experienced readers. Lesion conspicuity was assessed by the image contrast ratio (CR) and contrast-to-noise ratio (CNR). The intracranial region was divided into four quadrants and the impact of lesion location on detection was assessed in each slice. Six hundred and seven gadolinium-enhancing MS lesions were identified. GRE images were more sensitive for lesion detection (0.828) than SE images (0.767). Lesions showed a higher CR in SE than in GRE images, whereas the CNR was higher in GRE than SE. Most misclassifications occurred in the right posterior quadrant. The gadolinium-enhanced 2D T1-weighted GRE sequence at 3.0T MRI enables detection of enhancing MS lesions with higher sensitivity and better lesion conspicuity than 2D T1-weighted SE. Hence, we propose the use of gadolinium-enhanced GRE sequences rather than SE sequences for routine scanning of MS patients at 3.0T. (orig.)

  3. Impact of respiratory motion correction and spatial resolution on lesion detection in PET: a simulation study based on real MR dynamic data

    Science.gov (United States)

    Polycarpou, Irene; Tsoumpas, Charalampos; King, Andrew P.; Marsden, Paul K.

    2014-02-01

    The aim of this study is to investigate the impact of respiratory motion correction and spatial resolution on lesion detectability in PET as a function of lesion size and tracer uptake. Real respiratory signals describing different breathing types are combined with a motion model formed from real dynamic MR data to simulate multiple dynamic PET datasets acquired from a continuously moving subject. Lung and liver lesions were simulated with diameters ranging from 6 to 12 mm and lesion to background ratio ranging from 3:1 to 6:1. Projection data for 6 and 3 mm PET scanner resolution were generated using analytic simulations and reconstructed without and with motion correction. Motion correction was achieved using motion compensated image reconstruction. The detectability performance was quantified by a receiver operating characteristic (ROC) analysis obtained using a channelized Hotelling observer and the area under the ROC curve (AUC) was calculated as the figure of merit. The results indicate that respiratory motion limits the detectability of lung and liver lesions, depending on the variation of the breathing cycle length and amplitude. Patients with large quiescent periods had a greater AUC than patients with regular breathing cycles and patients with long-term variability in respiratory cycle or higher motion amplitude. In addition, small (less than 10 mm diameter) or low contrast (3:1) lesions showed the greatest improvement in AUC as a result of applying motion correction. In particular, after applying motion correction the AUC is improved by up to 42% with current PET resolution (i.e. 6 mm) and up to 51% for higher PET resolution (i.e. 3 mm). Finally, the benefit of increasing the scanner resolution is small unless motion correction is applied. This investigation indicates high impact of respiratory motion correction on lesion detectability in PET and highlights the importance of motion correction in order to benefit from the increased resolution of future

  4. Impact of respiratory motion correction and spatial resolution on lesion detection in PET: a simulation study based on real MR dynamic data

    International Nuclear Information System (INIS)

    Polycarpou, Irene; Tsoumpas, Charalampos; King, Andrew P; Marsden, Paul K

    2014-01-01

    The aim of this study is to investigate the impact of respiratory motion correction and spatial resolution on lesion detectability in PET as a function of lesion size and tracer uptake. Real respiratory signals describing different breathing types are combined with a motion model formed from real dynamic MR data to simulate multiple dynamic PET datasets acquired from a continuously moving subject. Lung and liver lesions were simulated with diameters ranging from 6 to 12 mm and lesion to background ratio ranging from 3:1 to 6:1. Projection data for 6 and 3 mm PET scanner resolution were generated using analytic simulations and reconstructed without and with motion correction. Motion correction was achieved using motion compensated image reconstruction. The detectability performance was quantified by a receiver operating characteristic (ROC) analysis obtained using a channelized Hotelling observer and the area under the ROC curve (AUC) was calculated as the figure of merit. The results indicate that respiratory motion limits the detectability of lung and liver lesions, depending on the variation of the breathing cycle length and amplitude. Patients with large quiescent periods had a greater AUC than patients with regular breathing cycles and patients with long-term variability in respiratory cycle or higher motion amplitude. In addition, small (less than 10 mm diameter) or low contrast (3:1) lesions showed the greatest improvement in AUC as a result of applying motion correction. In particular, after applying motion correction the AUC is improved by up to 42% with current PET resolution (i.e. 6 mm) and up to 51% for higher PET resolution (i.e. 3 mm). Finally, the benefit of increasing the scanner resolution is small unless motion correction is applied. This investigation indicates high impact of respiratory motion correction on lesion detectability in PET and highlights the importance of motion correction in order to benefit from the increased resolution of future

  5. Extended Preclinical Safety, Efficacy and Stability Testing of a Live-attenuated Chikungunya Vaccine Candidate.

    Directory of Open Access Journals (Sweden)

    Kenneth S Plante

    Full Text Available We recently described a new, live-attenuated vaccine candidate for chikungunya (CHIK fever, CHIKV/IRES. This vaccine was shown to be well attenuated, immunogenic and efficacious in protecting against CHIK virus (CHIKV challenge of mice and nonhuman primates. To further evaluate its preclinical safety, we compared CHIKV/IRES distribution and viral loads in interferon-α/β receptor-incompetent A129 mice to another CHIK vaccine candidate, 181/clone25, which proved highly immunogenic but mildly reactive in human Phase I/II clinical trials. Compared to wild-type CHIK virus, (wt-CHIKV, both vaccines generated lower viral loads in a wide variety of tissues and organs, including the brain and leg muscle, but CHIKV/IRES exhibited marked restrictions in dissemination and viral loads compared to 181/clone25, and was never found outside the blood, spleen and muscle. Unlike wt-CHIKV, which caused disrupted splenic architecture and hepatic lesions, histopathological lesions were not observed in animals infected with either vaccine strain. To examine the stability of attenuation, both vaccines were passaged 5 times intracranially in infant A129 mice, then assessed for changes in virulence by comparing parental and passaged viruses for footpad swelling, weight stability and survival after subcutaneous infection. Whereas strain 181/clone25 p5 underwent a significant increase in virulence as measured by weight loss (from 30% and mortality (from 0 to 100%, CHIKV/IRES underwent no detectible change in any measure of virulence (no significant weight loss and no mortality. These data indicate greater nonclinical safety of the CHIKV/IRES vaccine candidate compared to 181/clone25, further supporting its eligibility for human testing.

  6. The diagnostic value of magnetic resonance arthrography of the shoulder in detection and grading of SLAP lesions: Comparison with arthroscopic findings

    International Nuclear Information System (INIS)

    Amin, Mohammed Farghally; Youssef, Ahmed Omar

    2012-01-01

    Purpose: The purpose of the study is to determine the usefulness of magnetic resonance arthrography (MRA) in diagnosis and grading of superior labrum anterior to posterior (SLAP) lesions of the Glenoid Labrum Compared with surgery Material and methods: This was a prospective study including fifty nine clinically diagnosed SLAP patients. The study was done during the period from January 2008 to June 2010. All patients were submitted to history taking, clinical examination and conventional MRI examination of the shoulder, MRA was done in patients with negative conventional MRI, all of these patients underwent arthroscopy for diagnosis wither open or arthroscopy for diagnosis and treatment and results were compared with MRA findings. Main outcome measures: Sensitivity, specificity, positive and negative predictive values, and overall accuracy of MR arthrography in detection and grading of SLAP lesions of the gelnoid labrum. Results: Out of fifty nine patients, 25 patients had positive MR findings in conventional MRI, and 34 patients had negative MR findings, who underwent MR arthrography; 10 out of them had normal arthrogram (only 6 of them underwent arthroscopy), 22 had SLAP (superior labrum anterior to posterior) lesions, one had Bankart's lesion and one had internal impingement syndrome. These results were compared with arthroscopy results. The overall sensitivity of MRA in detection of SLAP lesions was 90% while the specificity was 50%, negative predictive value (NPV) was 66.6% and positive predicative value (PPV) was 81.8%. MRA and arthroscopy results were concurrent in 79.3% patients. Conclusion: MR arthrography is a sensitive minimally invasive technique for detection and grading of SLAP lesions, it can help in avoiding patients unnecessary diagnostic arthroscopy

  7. The diagnostic value of magnetic resonance arthrography of the shoulder in detection and grading of SLAP lesions: Comparison with arthroscopic findings

    Energy Technology Data Exchange (ETDEWEB)

    Amin, Mohammed Farghally, E-mail: Mohammed_amin37@yahoo.com [Department of Radiodiagnosis ElMinya University, ElMinya High Road, ElMinya (Egypt); Youssef, Ahmed Omar [Department of Orthropedic Surgery El Minya University, ElMinya (Egypt)

    2012-09-15

    Purpose: The purpose of the study is to determine the usefulness of magnetic resonance arthrography (MRA) in diagnosis and grading of superior labrum anterior to posterior (SLAP) lesions of the Glenoid Labrum Compared with surgery Material and methods: This was a prospective study including fifty nine clinically diagnosed SLAP patients. The study was done during the period from January 2008 to June 2010. All patients were submitted to history taking, clinical examination and conventional MRI examination of the shoulder, MRA was done in patients with negative conventional MRI, all of these patients underwent arthroscopy for diagnosis wither open or arthroscopy for diagnosis and treatment and results were compared with MRA findings. Main outcome measures: Sensitivity, specificity, positive and negative predictive values, and overall accuracy of MR arthrography in detection and grading of SLAP lesions of the gelnoid labrum. Results: Out of fifty nine patients, 25 patients had positive MR findings in conventional MRI, and 34 patients had negative MR findings, who underwent MR arthrography; 10 out of them had normal arthrogram (only 6 of them underwent arthroscopy), 22 had SLAP (superior labrum anterior to posterior) lesions, one had Bankart's lesion and one had internal impingement syndrome. These results were compared with arthroscopy results. The overall sensitivity of MRA in detection of SLAP lesions was 90% while the specificity was 50%, negative predictive value (NPV) was 66.6% and positive predicative value (PPV) was 81.8%. MRA and arthroscopy results were concurrent in 79.3% patients. Conclusion: MR arthrography is a sensitive minimally invasive technique for detection and grading of SLAP lesions, it can help in avoiding patients unnecessary diagnostic arthroscopy.

  8. Clinical relevance of studies on the accuracy of visual inspection for detecting caries lesions

    DEFF Research Database (Denmark)

    Gimenez, Thais; Piovesan, Chaiana; Braga, Mariana M

    2015-01-01

    Although visual inspection is the most commonly used method for caries detection, and consequently the most investigated, studies have not been concerned about the clinical relevance of this procedure. Therefore, we conducted a systematic review in order to perform a critical evaluation considering...... the clinical relevance and methodological quality of studies on the accuracy of visual inspection for assessing caries lesions. Two independent reviewers searched several databases through July 2013 to identify papers/articles published in English. Other sources were checked to identify unpublished literature...... to clinical relevance and the methodological quality of the studies were evaluated. 96 of the 5,578 articles initially identified met the inclusion criteria. In general, most studies failed in considering some clinically relevant aspects: only 1 included study validated activity status of lesions, no study...

  9. Dynamic multislice helical CT of maxillomandibular lesions. Distinction of ameloblastomas from other cystic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Tozaki, Mitsuhiro; Hayashi, Katsuhiko; Fukuda, Kunihiko [Jikei Univ., Tokyo (Japan). School of Medicine

    2001-10-01

    The purpose of this study was to evaluate the clinical usefulness of dynamic multislice helical CT in differentiating ameloblastoma from other cystic lesions in cases of maxillomandibular cystic lesions. The study included 32 patients with maxillomandibular cystic lesions (ameloblastoma [n=6], myxofibroma [n=1], odontogenic keratocyst [n=3], dentigerous cyst [n=11], radicular cyst [n=11], and paradental cyst [n=2]). Dynamic study was performed before and 30 sec, and 90 sec after intravenous contrast medium administration. CT density values and percentage of density increase were calculated at 30 and 90 sec. In five cases of ameloblastoma, a rapidly enhancing area was detected within the cystic lesions at 30 sec, while no apparent rapid enhancement was seen in the other cystic lesions. Three cysts showed gradual enhancement in the marginal area at 90 sec. Comparing ameloblastoma and other kinds of cysts, we found significant differences in the percentage of density increase at 30 sec (p<0.01) and 90 sec (p<0.05). Dynamic multislice helical CT is useful in the diagnosis of cystic lesions of the maxillomandibular region, especially in the detection of neovascularities in ameloblastoma. (author)

  10. Dynamic multislice helical CT of maxillomandibular lesions. Distinction of ameloblastomas from other cystic lesions

    International Nuclear Information System (INIS)

    Tozaki, Mitsuhiro; Hayashi, Katsuhiko; Fukuda, Kunihiko

    2001-01-01

    The purpose of this study was to evaluate the clinical usefulness of dynamic multislice helical CT in differentiating ameloblastoma from other cystic lesions in cases of maxillomandibular cystic lesions. The study included 32 patients with maxillomandibular cystic lesions (ameloblastoma [n=6], myxofibroma [n=1], odontogenic keratocyst [n=3], dentigerous cyst [n=11], radicular cyst [n=11], and paradental cyst [n=2]). Dynamic study was performed before and 30 sec, and 90 sec after intravenous contrast medium administration. CT density values and percentage of density increase were calculated at 30 and 90 sec. In five cases of ameloblastoma, a rapidly enhancing area was detected within the cystic lesions at 30 sec, while no apparent rapid enhancement was seen in the other cystic lesions. Three cysts showed gradual enhancement in the marginal area at 90 sec. Comparing ameloblastoma and other kinds of cysts, we found significant differences in the percentage of density increase at 30 sec (p<0.01) and 90 sec (p<0.05). Dynamic multislice helical CT is useful in the diagnosis of cystic lesions of the maxillomandibular region, especially in the detection of neovascularities in ameloblastoma. (author)

  11. Brain MR post-gadolinium contrast in multiple sclerosis: the role of magnetization transfer and image subtraction in detecting more enhancing lesions

    Energy Technology Data Exchange (ETDEWEB)

    Gavra, M.M.; Gouliamos, A.D.; Vlahos, L.J. [Department of Radiology, ' ' Aretaieion' ' Hospital,University of Athens Medical School, Athens (Greece); Voumvourakis, C.; Sfagos, C. [Department of Neurology, ' ' Eginiteion' ' Hospital, University of Athens Medical School, Athens (Greece)

    2004-03-01

    Our purpose was to evaluate the role of magnetization transfer and image subtraction in detecting more enhancing lesions in brain MR imaging of patients with multiple sclerosis (MS). Thirty-one MS patients underwent MR imaging of the brain with T1-weighted spin echo sequences without and with magnetization transfer (MT) using a 1.5 T imager. Both sequences were acquired before and after intravenous injection of a paramagnetic contrast agent. Subtraction images in T1-weighted sequences were obtained by subtracting the pre-contrast images from the post-contrast ones. A significant difference was found between the numbers of enhanced areas in post-gadolinium T1-weighted images without and with MT (p=0.020). The post-gadolinium T1-weighted images with MT allowed the detection of an increased (13) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. A significant difference was also found between the numbers of enhanced areas in post-gadolinium T1-weighted images without MT and subtraction images without MT (p=0.020). The subtraction images without MT allowed the detection of an increased (10) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. Magnetization transfer contrast and subtraction techniques appear to be the simplest and least time-consuming applications to improve the conspicuity and detection of contrast-enhancing lesions in patients with MS. (orig.)

  12. Brain MR post-gadolinium contrast in multiple sclerosis: the role of magnetization transfer and image subtraction in detecting more enhancing lesions

    International Nuclear Information System (INIS)

    Gavra, M.M.; Gouliamos, A.D.; Vlahos, L.J.; Voumvourakis, C.; Sfagos, C.

    2004-01-01

    Our purpose was to evaluate the role of magnetization transfer and image subtraction in detecting more enhancing lesions in brain MR imaging of patients with multiple sclerosis (MS). Thirty-one MS patients underwent MR imaging of the brain with T1-weighted spin echo sequences without and with magnetization transfer (MT) using a 1.5 T imager. Both sequences were acquired before and after intravenous injection of a paramagnetic contrast agent. Subtraction images in T1-weighted sequences were obtained by subtracting the pre-contrast images from the post-contrast ones. A significant difference was found between the numbers of enhanced areas in post-gadolinium T1-weighted images without and with MT (p=0.020). The post-gadolinium T1-weighted images with MT allowed the detection of an increased (13) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. A significant difference was also found between the numbers of enhanced areas in post-gadolinium T1-weighted images without MT and subtraction images without MT (p=0.020). The subtraction images without MT allowed the detection of an increased (10) number of enhancing lesions compared with post-gadolinium T1-weighted images without MT. Magnetization transfer contrast and subtraction techniques appear to be the simplest and least time-consuming applications to improve the conspicuity and detection of contrast-enhancing lesions in patients with MS. (orig.)

  13. Evaluation of a radiographic method to detect tibial dyschondroplasia lesions in broilers

    Directory of Open Access Journals (Sweden)

    K Pelicia

    2012-06-01

    Full Text Available This study aimed at developing radiographic techniques for the early detection of dyschondroplastic lesions in the tibia of broilers. The experiment was carried out at the facilities of UNIFOR/MG and Formiga and UNIFENAS/ Alfenas with 420 one-day-old male Cobb broilers. At 20 days of age, all birds were radiographed and identified with an alpha-numeric metal ring in the right leg. At 40 days of age, 42 broilers previously selected as a function of bone mineral density and lesion thickness scores were again radiographed and scored, and then sacrificed. Their right tibia was removed for gross and histological examination of the growth plate. The results showed that radiographic techniques are correlated with gross and histological examination and that there was no significant differences among techniques (P>0.05. it was concluded that the use of radiographic examination to identify tibial dyschondroplasia in broilers precludes the use of bone mineral density to diagnose this condition. The non-parametric statistical Chi-square test at 5% significance level was used to analyze the results.

  14. A ROC-based feature selection method for computer-aided detection and diagnosis

    Science.gov (United States)

    Wang, Songyuan; Zhang, Guopeng; Liao, Qimei; Zhang, Junying; Jiao, Chun; Lu, Hongbing

    2014-03-01

    Image-based computer-aided detection and diagnosis (CAD) has been a very active research topic aiming to assist physicians to detect lesions and distinguish them from benign to malignant. However, the datasets fed into a classifier usually suffer from small number of samples, as well as significantly less samples available in one class (have a disease) than the other, resulting in the classifier's suboptimal performance. How to identifying the most characterizing features of the observed data for lesion detection is critical to improve the sensitivity and minimize false positives of a CAD system. In this study, we propose a novel feature selection method mR-FAST that combines the minimal-redundancymaximal relevance (mRMR) framework with a selection metric FAST (feature assessment by sliding thresholds) based on the area under a ROC curve (AUC) generated on optimal simple linear discriminants. With three feature datasets extracted from CAD systems for colon polyps and bladder cancer, we show that the space of candidate features selected by mR-FAST is more characterizing for lesion detection with higher AUC, enabling to find a compact subset of superior features at low cost.

  15. Detection of occlusal caries lesions using fluorescence: correlation between histology and obtained results for Diagnodent and spectroscopy

    International Nuclear Information System (INIS)

    Rocha-Cabral, Renata Maciel

    2006-01-01

    The aims of this study were to develop and test a method to detect caries lesions in vivo and in vitro, using a portable spectrometer (PS); to analyze the performance of PS as well as the commercial device Diagnodent (Dd); correlate them with the gold standard, their transversal section areas and lesions depth and between themselves. 66 occlusal pre-molars sites were examined in vivo with Dd. Sequentially, fluorescence (λexc ∼ 657 nm) was collected by an optical fiber, conducted to PS and then analyzed as spectra, which were normalized and had calculated the Ratios of their Areas Under the Curves (RAUC) of carious and sound tissues. Experiments were conducted in vitro in the same sites. Gold Standard was obtained by polarized light microscopy. Pearson correlation was used to compare the devices with transversal section area, lesions depth and between themselves. The area under ROC curve, sensitivity, specificity as well as accuracy were calculated and verified with McNemar test. Dd and RAUC showed statistically significant correlation with gold standard (p < 0.01 for Dd and p < 0.05 for RAUC) and between themselves (r = 0,83 in vivo and r = 0,87 in vitro). Although it was significant, the devices showed low correlation with depth of lesions in vivo and in vitro (r = ∼ 0.43). The transversal section area of the lesion had no influence on readings in both devices. Dd showed higher sensitivity (0.76) than PS (0.60) in vivo (p < 0.05), though this fact was not able to improve its performance. In turn, PS showed higher sensitivity (0.88) than Dd (0.79) in vitro, but this difference was not significantly. The other parameters did not show statistically significant differences (p < 0.05) between methods. PS showed positive correlation with Dd, equal correlation with lesions depth and higher ability of detecting the disease in vitro, what suggests that if accompanied with a conic and an angulated probe and a dedicated software, the PS method could be useful in clinics

  16. Autofluorescence of pigmented skin lesions using a pulsed UV laser with synchronized detection: clinical results

    DEFF Research Database (Denmark)

    Cheng, Haynes Pak Hay; Svenmarker, Pontus; Tidemand-Lichtenberg, Peter

    2010-01-01

    signal, which may in turn produce high contrast images that improve diagnosis, even in the presence of ambient room light. The synchronized set-up utilizes a compact, diode pumped, pulsed UV laser at 355 nm which is coupled to a CCD camera and a liquid crystal tunable filter. The excitation and image......We report preliminary clinical results of autofluorescence imaging of malignant and benign skin lesions, using pulsed 355 nm laser excitation with synchronized detection. The novel synchronized detection system allows high signal-to-noise ratio to be achieved in the resulting autofluorescence...

  17. Detection of retinal lesions in diabetic retinopathy: comparative evaluation of 7-field digital color photography versus red-free photography.

    Science.gov (United States)

    Venkatesh, Pradeep; Sharma, Reetika; Vashist, Nagender; Vohra, Rajpal; Garg, Satpal

    2015-10-01

    Red-free light allows better detection of vascular lesions as this wavelength is absorbed by hemoglobin; however, the current gold standard for the detection and grading of diabetic retinopathy remains 7-field color fundus photography. The goal of this study was to compare the ability of 7-field fundus photography using red-free light to detect retinopathy lesions with corresponding images captured using standard 7-field color photography. Non-stereoscopic standard 7-field 30° digital color fundus photography and 7-field 30° digital red-free fundus photography were performed in 200 eyes of 103 patients with various grades of diabetic retinopathy ranging from mild to moderate non-proliferative diabetic retinopathy to proliferative diabetic retinopathy. The color images (n = 1,400) were studied with corresponding red-free images (n = 1,400) by one retina consultant (PV) and two senior residents training in retina. The various retinal lesions [microaneurysms, hemorrhages, hard exudates, soft exudates, intra-retinal microvascular anomalies (IRMA), neovascularization of the retina elsewhere (NVE), and neovascularization of the disc (NVD)] detected by all three observers in each of the photographs were noted followed by determination of agreement scores using κ values (range 0-1). Kappa coefficient was categorized as poor (≤0), slight (0.01-0.20), fair (0.2 -0.40), moderate (0.41-0.60), substantial (0.61-0.80), and almost perfect (0.81-1). The number of lesions detected by red-free images alone was higher for all observers and all abnormalities except hard exudates. Detection of IRMA was especially higher for all observers with red-free images. Between image pairs, there was substantial agreement for detection of hard exudates (average κ = 0.62, range 0.60-0.65) and moderate agreement for detection of hemorrhages (average κ = 0.52, range 0.45-0.58), soft exudates (average κ = 0.51, range 0.42-0.61), NVE (average κ = 0.47, range 0.39-0.53), and NVD

  18. Influence of attenuation correction and reconstruction techniques on the detection of hypoperfused lesions in brain SPECT studies

    International Nuclear Information System (INIS)

    Ghoorun, S.; Groenewald, W.A.; Baete, K.; Nuyts, J.; Dupont, P.

    2004-01-01

    Full text: Aim: To study the influence of attenuation correction and the reconstruction technique on the detection of hypoperfused lesions in brain SPECT imaging, Material and Methods: A simulation experiment was used in which the effects of attenuation and reconstruction were decoupled, A high resolution SPECT phantom was constructed using the BrainWeb database, In this phantom, activity values were assigned to grey and white matter (ratio 4:1) and scaled to obtain counts of the same magnitude as in clinical practice, The true attenuation map was generated by assigning attenuation coefficients to each tissue class (grey and white matter, cerebral spinal fluid, skull, soft and fatty tissue and air) to create a non-uniform attenuation map, The uniform attenuation map was calculated using an attenuation coefficient of 0.15 cm-1, Hypoperfused lesions of varying intensities and sizes were added. The phantom was then projected as typical SPECT projection data, taking into account attenuation and collimator blurring with the addition of Poisson noise, The projection data was reconstructed using four different methods of reconstruction: (1) filtered backprojection (FBP) with the uniform attenuation map; (2) FBP using the true attenuation map; (3) ordered subset expectation maximization (OSEM) (equivalent to 423 iterations) with a uniform attenuation map; and (4) OSEM with a true attenuation map. Different Gaussian postsmooth kernels were applied to the reconstructed images. Results: The analysis of the reconstructed data was performed using figures of merit such as signal to noise ratio (SNR), bias and variance. The results illustrated that uniform attenuation correction offered slight deterioration (less than 2%) with regard to SNR when compared to the ideal attenuation map. which in reality is not known. The iterative techniques produced superior signal to noise ratios (increase of 5 - 20 % depending on the lesion and the postsmooth) in comparison to the FBP methods

  19. Impact of real-time virtual sonography, a coordinated sonography and MRI system that uses an image fusion technique, on the sonographic evaluation of MRI-detected lesions of the breast in second-look sonography.

    Science.gov (United States)

    Nakano, Shogo; Kousaka, Junko; Fujii, Kimihito; Yorozuya, Kyoko; Yoshida, Miwa; Mouri, Yukako; Akizuki, Miwa; Tetsuka, Rie; Ando, Takahito; Fukutomi, Takashi; Oshima, Yukihiko; Kimura, Junko; Ishiguchi, Tsuneo; Arai, Osamu

    2012-08-01

    The aim of this study was to verify the utility of second-look sonography using real-time virtual sonography (RVS)-a coordinated sonography with an MRI system that uses an image fusion technique with magnetic navigation-on the sonographic evaluation of MRI-detected lesions of the breast. Of the 196 consecutive patients who were examined with breast MRI in our hospital from 2006 to 2009, those patients who underwent second-look sonography to identify MRI-detected lesions were enrolled in this study. MRI was performed using a 1.5-T imager with the patient in a supine position. To assess the efficacy benefits of RVS, the correlations between lesion detection rates, MRI features, distribution, and histopathological classification on second-look sonography using conventional B-mode or RVS were analyzed. Of the 196 patients, 55 (28 %) demonstrated 67 lesions initially detected by MRI, followed by second-look sonography. Of the 67 MRI-detected lesions, 18 (30 %) were identified with second-look sonography using conventional B-mode alone, whereas 60 (90 %) lesions were detected with second-look sonography using RVS (p use of RVS on second-look sonography significantly increases the sonographic detection rate of MRI-detected lesions without operator dependence.

  20. Detection of glass particles on bone lesions using SEM-EDS.

    Science.gov (United States)

    Montoriol, Romain; Guilbeau-Frugier, Céline; Chantalat, Elodie; Roumiguié, Mathieu; Delisle, Marie-Bernadette; Payré, Bruno; Telmon, Norbert; Savall, Frédéric

    2017-09-01

    The problem of identifying the wounding agent in forensic cases is recurrent. Moreover, when several tools are involved, distinguishing the origin of lesions can be difficult. Scanning electron microscopy (SEM)/energy dispersive X-ray analysis (EDS) equipment is increasingly available to the scientific and medical community, and some studies have reported its use in forensic anthropology. However, at our knowledge, no study has reported the use of SEM-EDS in forensic cases involving glass tools, whether in case reports or experiments. We performed an experimental study on human rib fragments, on which we manually created wounds using fragments of window and mirror glass. SEM-EDS was executed on samples without any further preparation on low vacuum mode, then on the same samples after defleshing them completely by boiling them. Window and mirror glass particles were detected on experimental wounds. Both had silica in their spectra, and the opaque side of the mirror contained titanium, allowing for their identification. Boiling and defleshing the bone samples involved a loss of information in terms of the number of wounds detected as positive for glass particles and in the number of glass particles detected, for both window and mirror glass. We suggest the analysis of wounds with suspected glass particles using low vacuum mode and with no defleshment by boiling.

  1. Role of Visual Inspection of Cervix with Acetic Acid (VIA in Detecting Precancerous Lesions of Cervix

    Directory of Open Access Journals (Sweden)

    Kamrun Nessa

    2014-01-01

    Full Text Available Background: Carcinoma of cervix is the most common malignancy in female and a major public health problem worldwide. It is the leading cause of death from cancer among women in low resource settings. In Bangladesh, mortality rate is high as most of the cases with cervical cancer are diagnosed in advanced stage. World Health Organization considers cervical cancer as a preventable disease as it can be identified in preinvasive stage. Considerable efforts have been given in detection and treatment of the condition all over the world. A number of cervical cancer screening tests are available. Among them, visual inspection of cervix with acetic acid is rational and can be competently performed by physicians with proper training. Objective: To find out the feasibility of the visual inspection of cervix with acetic acid for the detection of the precancerous lesions of the cervix in our country. Materials and Methods: This cross sectional, analytical study was carried out among the patients attending the outpatient department of Bangabandhu Sheikh Mujib Medical University (BSMMU who were VIA positive and sent for colposcopy in the colposcopy clinic in the department of Obstetrics and Gynecology in BSMMU from June to December 2004. Two hundred samples were considered for this study. Results: Out of 200 cases, colposcopically 85% had CIN and invasive lesions, 4% had inflammatory lesions while 11% had normal findings. Colposcopy directed punch biopsy revealed positive lesions in 81%, 4% had inflammatory lesions while 15% had normal findings. Conclusion: The study concluded that VIA and colposcopy are the important methods in the evaluation of cervical premalignancy. VIA may be an important tool for screening of cervical cancer in low resource settings as it is simple, easy to perform and cost-effective. After screening, VIA positive cases must be referred for colposcopic evaluation. We can screen cervical cancer by VIA all over the country and thus reduce

  2. Automated lung nodule classification following automated nodule detection on CT: A serial approach

    International Nuclear Information System (INIS)

    Armato, Samuel G. III; Altman, Michael B.; Wilkie, Joel; Sone, Shusuke; Li, Feng; Doi, Kunio; Roy, Arunabha S.

    2003-01-01

    We have evaluated the performance of an automated classifier applied to the task of differentiating malignant and benign lung nodules in low-dose helical computed tomography (CT) scans acquired as part of a lung cancer screening program. The nodules classified in this manner were initially identified by our automated lung nodule detection method, so that the output of automated lung nodule detection was used as input to automated lung nodule classification. This study begins to narrow the distinction between the 'detection task' and the 'classification task'. Automated lung nodule detection is based on two- and three-dimensional analyses of the CT image data. Gray-level-thresholding techniques are used to identify initial lung nodule candidates, for which morphological and gray-level features are computed. A rule-based approach is applied to reduce the number of nodule candidates that correspond to non-nodules, and the features of remaining candidates are merged through linear discriminant analysis to obtain final detection results. Automated lung nodule classification merges the features of the lung nodule candidates identified by the detection algorithm that correspond to actual nodules through another linear discriminant classifier to distinguish between malignant and benign nodules. The automated classification method was applied to the computerized detection results obtained from a database of 393 low-dose thoracic CT scans containing 470 confirmed lung nodules (69 malignant and 401 benign nodules). Receiver operating characteristic (ROC) analysis was used to evaluate the ability of the classifier to differentiate between nodule candidates that correspond to malignant nodules and nodule candidates that correspond to benign lesions. The area under the ROC curve for this classification task attained a value of 0.79 during a leave-one-out evaluation

  3. Detection and clonal analysis of anaerobic bacteria associated to endodontic-periodontal lesions.

    Science.gov (United States)

    Pereira, Cássio V; Stipp, Rafael N; Fonseca, Douglas C; Pereira, Luciano J; Höfling, José F

    2011-12-01

    Microbial agents in root canal systems can induce periodontal inflammation. The aims of this study are to detect anaerobic microorganisms in endodontic-periodontal lesions, determine the genetic diversity among them, and assess the simultaneous colonization of the pulp and periodontal microenvironments by a single clone. Twenty-seven teeth of patients with endodontic-periodontal lesions were selected. Samples were spread on an agar-blood medium, the detection of each species was performed using a polymerase chain reaction, and the determination of the simultaneous presence of the same species in the microenvironments by one or more clones was determined using arbitrarily primed PCR. Prevotella intermedia (Pi) was the most prevalent species of the colonies in periodontal pockets, whereas Porphyromonas gingivalis (Pg) and Pi were the more prevalent in root canals. Isolates of Pi and Pg were simultaneously identified in root canals and periodontal pockets. Eighteen percent of teeth exhibited the simultaneous colonization by Pg, Tannerella forsythia (previously T. forsythensis), and Porphyromonas endodontalis in the pulp and periodontal microenvironments. The presence of these species was noted even in niches from which no colonies were isolated. Seventeen different genotypes were found in periodontal and pulp sites, with the majority of sites colonized by one or two different genotypes. A high degree of genotype similarity was found for samples of Pg isolated from only one site as well as for those isolated from both microenvironments. Different clones of Pi and Pg with a high intraspecific genotype similarity were found to colonize the same anatomic sites in endodontic-periodontal infections.

  4. Optical Assessment of Caries Lesion Structure and Activity

    Science.gov (United States)

    Lee, Robert Chulsung

    New, more sophisticated diagnostic tools are needed for the detection and characterization of caries lesions in the early stages of development. It is not sufficient to simply detect caries lesions, methods are needed to assess the activity of the lesion and determine if chemical or surgical intervention is needed. Previous studies have demonstrated that polarization sensitive optical coherence tomography (PS-OCT) can be used to nondestructively image the subsurface lesion structure and measure the thickness of the highly mineralized surface zone. Other studies have demonstrated that the rate of dehydration can be correlated with the lesion activity and that the rate can be measured using optical methods. The main objective of this work was to test the hypothesis that optical methods can be used to assess lesion activity on tooth coronal and root surfaces. Simulated caries models were used to develop and validate an algorithm for detecting and measuring the highly mineralized surface layer using PS-OCT. This work confirmed that the algorithm was capable of estimating the thickness of the highly mineralized surface layer with high accuracy. Near-infrared (NIR) reflectance and thermal imaging methods were used to assess activity of caries lesions by measuring the state of lesion hydration. NIR reflectance imaging performed the best for artificial enamel and natural coronal caries lesion samples, particularly at wavelengths coincident with the water absorption band at 1460-nm. However, thermal imaging performed the best for artificial dentin and natural root caries lesion samples. These novel optical methods outperformed the conventional methods (ICDAS II) in accurately assessing lesion activity of natural coronal and root caries lesions. Infrared-based imaging methods have shown potential for in-vivo applications to objectively assess caries lesion activity in a single examination. It is likely that if future clinical trials are a success, this novel imaging

  5. Breath-hold [68Ga]DOTA-TOC PET/CT in neuroendocrine tumors: detection of additional lesions and effects on quantitative parameters.

    Science.gov (United States)

    Zirnsak, Mariana; Bärwolf, Robert; Freesmeyer, Martin

    2016-11-08

    Respiratory motion during PET/CT acquisition generates artifacts in the form of breath-related blurring, which influences the lesion detectability and diagnostic accuracy. The goal of this study was to verify whether breath-hold [68Ga]DOTA-TOC PET/CT (bhPET) allows detection of additional foci compared to free-breathing PET/CT (fbPET), and to assess the impact of breath-holding on standard uptake values (SUV) and isocontoured volume (Vic40) in patients with neuroendocrine tumors (NET). Patients with NET (n=39) were included in this study. BhPET and fbPET characteristics of 96 lesions were compared, and correlated with standard contrast-enhanced (ce) CT and MRI for lesion verification. Quantitative parameters SUV (max and mean) and Vic40 were assessed for both methods and evaluated by linear regression and Spearman's correlation. The impact of lesion size, localization and time interval between investigations was also analyzed. bhPET identified one additional metastasis not seen at fbPET but visible at ceMRI. Another additional bhPET focus did not have a morphological correlate. At bhPET, the SUVmax and SUVmean proved significantly higher and the Vic40 significantly lower than at fbPET. Lesion size, localization and time intervals did not impact significantly on SUV or Vic40. Currently, routine use of breath-hold [68Ga]DOTA-TOC PET/CT cannot be recommended as only one additional lesion was identified. Therefore, bhPET has currently no indication in patients with NET. If technical improvements regarding PET/CT scanner sensitivity are available, bhPET should be reevaluated in the future.

  6. The impact of noisy and misaligned attenuation maps on human-observer performance at lesion detection in SPECT

    Science.gov (United States)

    Wells, R. G.; Gifford, H. C.; Pretorius, P. H.; Famcombe, T. H.; Narayanan, M. V.; King, M. A.

    2002-06-01

    We have demonstrated an improvement due to attenuation correction (AC) at the task of lesion detection in thoracic SPECT images. However, increased noise in the transmission data due to aging sources or very large patients, and misregistration of the emission and transmission maps, can reduce the accuracy of the AC and may result in a loss of lesion detectability. We investigated the impact of noise in and misregistration of transmission data, on the detection of simulated Ga-67 thoracic lesions. Human-observer localization-receiver-operating-characteristic (LROC) methodology was used to assess performance. Both emission and transmission data were simulated using the MCAT computer phantom. Emission data were reconstructed using OSEM incorporating AC and detector resolution compensation. Clinical noise levels were used in the emission data. The transmission-data noise levels ranged from zero (noise-free) to 32 times the measured clinical levels. Transaxial misregistrations of 0.32, 0.63, and 1.27 cm between emission and transmission data were also examined. Three different algorithms were considered for creating the attenuation maps: filtered backprojection (FBP), unbounded maximum-likelihood (ML), and block-iterative transmission AB (BITAB). Results indicate that a 16-fold increase in the noise was required to eliminate the benefit afforded by AC, when using FBP or ML to reconstruct the attenuation maps. When using BITAB, no significant loss in performance was observed for a 32-fold increase in noise. Misregistration errors are also a concern as even small errors here reduce the performance gains of AC.

  7. Incidentally detected enhancing lesions found in breast MRI: analysis of apparent diffusion coefficient and T2 signal intensity significantly improves specificity

    Energy Technology Data Exchange (ETDEWEB)

    Arponen, Otso; Masarwah, Amro; Taina, Mikko [Kuopio University Hospital, Kuopio University Hospital, Diagnostic Imaging Centre, Department of Clinical Radiology, PO Box 1777, Kuopio (Finland); Kuopio University Hospital, University of Eastern Finland, Institute of Clinical Medicine, School of Medicine, Department of Clinical Radiology, PO Box 1777, Kuopio (Finland); Sutela, Anna; Koenoenen, Mervi; Hakumaeki, Juhana; Sudah, Mazen [Kuopio University Hospital, Kuopio University Hospital, Diagnostic Imaging Centre, Department of Clinical Radiology, PO Box 1777, Kuopio (Finland); Sironen, Reijo [Kuopio University Hospital, Kuopio University Hospital, Department of Pathology, PO Box 1777, Kuopio (Finland); Kuopio University Hospital, University of Eastern Finland, Institute of Clinical Medicine, School of Medicine, Clinical Pathology and Forensic Medicine, PO Box 1777, Kuopio (Finland); University of Eastern Finland, Cancer Center of Eastern Finland, Kuopio (Finland); Vanninen, Ritva [Kuopio University Hospital, Kuopio University Hospital, Diagnostic Imaging Centre, Department of Clinical Radiology, PO Box 1777, Kuopio (Finland); Kuopio University Hospital, University of Eastern Finland, Institute of Clinical Medicine, School of Medicine, Department of Clinical Radiology, PO Box 1777, Kuopio (Finland); University of Eastern Finland, Cancer Center of Eastern Finland, Kuopio (Finland)

    2016-12-15

    To evaluate the value of adding T2- and diffusion-weighted imaging (DWI) to the BI-RADS registered classification in MRI-detected lesions. This retrospective study included 112 consecutive patients who underwent 3.0T structural breast MRI with T2- and DWI on the basis of EUSOMA recommendations. Morphological and kinetic features, T2 signal intensity (T2 SI) and apparent diffusion coefficient (ADC) findings were assessed. Thirty-three (29.5 %) patients (mean age 57.0 ± 12.7 years) had 36 primarily MRI-detected incidental lesions of which 16 (44.4 %) proved to be malignant. No single morphological or kinetic feature was associated with malignancy. Both low T2 SI (P = 0.009) and low ADC values (≤0.87 x 10{sup -3} mm{sup 2}s{sup -1}, P < 0.001) yielded high specificity (80.0 %/80.0 %). The BI-RADS classification supplemented with information from DWI and T2-WI improved the diagnostic performance of the BI-RADS classification as sensitivity remained 100 % and specificity improved from 30 % to 65.0 %. The numbers of false positive lesions declined from 39 % (N = 14) to 19 % (N = 7). MRI-detected incidental lesions may be challenging to characterize as they have few specific malignancy indicating features. The specificity of MRI can be improved by incorporating T2 SI and ADC values into the BI-RADS assessment. (orig.)

  8. Benign fibroosseous lesions

    Directory of Open Access Journals (Sweden)

    Cansu Köseoğlu Seçgin

    2016-05-01

    Full Text Available Benign fibroosseous lesions represent a group of lesions that share the same basic evolutive mechanism and are characterized by replacement of normal bone with a fibrous connective tissue that gradually undergoes mineralization. These lesions are presented by a variety of diseases including developmental, reactive-dysplastic processes and neoplasms. Depending on the nature and amount of calcified tissue, they can be observed as radiolucent, mixed or radiopaque. Their radiographic features could be well-defined or indistinguishable from the surrounding bone tissue. They can be asymptomatic as in osseous dysplasias and can be detected incidentally on radiographs, or they can lead to expansion in the affected bone as in ossifying fibroma. All fibroosseous lesions seen in the jaws and face are variations of the same histological pattern. Therefore, detailed clinical and radiographic evaluation in differential diagnosis is important. In this review, fibroosseous benign lesions are classified as osseous dysplasia, fibrous dysplasia and fibroosseous tumors; and radiographic features and differential diagnosis of these lesions are reviewed taking into account this classification.

  9. Representability of metastatic bone lesions in magnification radiography

    International Nuclear Information System (INIS)

    Togawa, Takashi

    1981-01-01

    Magnification radiography, bone scintigraphy, and normal roentgenography were performed on patients with malignant tumors to detect their bone metastases, and from the results obtained, these diagnostic procedures were evaluated for the detectability and representability of metastatic bone lesions. Bone scan and normal roentgenography were performed on 90 metastatic bone lesions in 37 patients, and magnification radiography was done on 14 bone lesions noted in 10 of the 37 and another with benign osseous change. Among the three, bone scintigraphy was best, and magnification radiography and normal roentgenography did not differ significantly in detectability. In magnification radiography, some metastatic bone lesions were represented more clearly than by normal roentgeography, but some were not. As regards the representability of the ribs, magnification radiography was very useful. One case of bone destruction was detected by magnification radiography, but not by normal roentgenography. (author)

  10. Diagnostic utility of candidate definitions for demonstrating axial spondyloarthritis on magnetic resonance imaging of the spine

    DEFF Research Database (Denmark)

    Weber, Ulrich; Zhao, Zheng; Rufibach, Kaspar

    2015-01-01

    OBJECTIVE: A recent consensus statement has suggested ≥3 corner inflammatory lesions (CILs) or several corner fatty lesions (CFLs) as candidate criteria indicative of axial spondyloarthritis (SpA) on magnetic resonance imaging (MRI) of the spine. The aim of this study was to evaluate the diagnostic...

  11. What affects detectability of lesion–deficit relationships in lesion studies?

    Directory of Open Access Journals (Sweden)

    Kayo Inoue

    2014-01-01

    Our simulations offer a quantitative basis for interpreting lesion studies in cognitive neuroscience. We suggest ways in which lesion simulation and analysis frameworks could be productively extended.

  12. DISK DETECTIVE: DISCOVERY OF NEW CIRCUMSTELLAR DISK CANDIDATES THROUGH CITIZEN SCIENCE

    Energy Technology Data Exchange (ETDEWEB)

    Kuchner, Marc J.; McElwain, Michael; Padgett, Deborah L. [NASA Goddard Space Flight Center Exoplanets and Stellar Astrophysics Laboratory, Code 667 Greenbelt, MD 21230 (United States); Silverberg, Steven M.; Wisniewski, John P. [Homer L. Dodge Department of Physics and Astronomy The University of Oklahoma 440 W. Brooks St. Norman, OK 73019 (United States); Bans, Alissa S. [Valparaiso University, Department of Physics and Astronomy, Neils Science Center, 1610 Campus Drive East, Valparaiso, IN 46383 (United States); Bhattacharjee, Shambo [International Space University 1 Rue Jean-Dominique Cassini F-67400 Illkirch-Graffenstaden (France); Kenyon, Scott J. [Smithsonian Astrophysical Observatory 60 Garden Street Cambridge, MA 02138 (United States); Debes, John H. [Space Telescope Science Institute 3700 San Martin Dr. Baltimore, MD 21218 (United States); Currie, Thayne [National Astronomical Observatory of Japan 650 N A’ohokhu Place Hilo, HI 96720 (United States); García, Luciano [Observatorio Astronómico de Córdoba Universidad Nacional de Córdoba Laprida 854, X5000BGR, Córdoba (Argentina); Jung, Dawoon [Korea Aerospace Research Institute Lunar Exploration Program Office 169-84 Gwahak-ro, Yuseong-gu, Daejeon 34133 (Korea, Republic of); Lintott, Chris [Denys Wilkinson Building Keble Road Oxford, OX1 3RH (United Kingdom); Rebull, Luisa M. [Infrared Processing and Analaysis Center Caltech M/S 314-6 1200 E. California Blvd. Pasadena, CA 91125 (United States); Nesvold, Erika, E-mail: Marc.Kuchner@nasa.gov, E-mail: michael.w.mcelwain@nasa.gov, E-mail: deborah.l.padgett@nasa.gov, E-mail: carol.a.grady@nasa.gov, E-mail: silverberg@ou.edu, E-mail: wisniewski@ou.edu [Department of Terrestrial Magnetism, Carnegie Institution of Washington, 5241 Broad Branch Road, NW, Washington, DC 20015-1305 (United States); Collaboration: Disk Detective Collaboration; and others

    2016-10-20

    The Disk Detective citizen science project aims to find new stars with 22 μ m excess emission from circumstellar dust using data from NASA’s Wide-field Infrared Survey Explorer ( WISE ) mission. Initial cuts on the AllWISE catalog provide an input catalog of 277,686 sources. Volunteers then view images of each source online in 10 different bands to identify false positives (galaxies, interstellar matter, image artifacts, etc.). Sources that survive this online vetting are followed up with spectroscopy on the FLWO Tillinghast telescope. This approach should allow us to unleash the full potential of WISE for finding new debris disks and protoplanetary disks. We announce a first list of 37 new disk candidates discovered by the project, and we describe our vetting and follow-up process. One of these systems appears to contain the first debris disk discovered around a star with a white dwarf companion: HD 74389. We also report four newly discovered classical Be stars (HD 6612, HD 7406, HD 164137, and HD 218546) and a new detection of 22 μ m excess around the previously known debris disk host star HD 22128.

  13. DISK DETECTIVE: DISCOVERY OF NEW CIRCUMSTELLAR DISK CANDIDATES THROUGH CITIZEN SCIENCE

    International Nuclear Information System (INIS)

    Kuchner, Marc J.; McElwain, Michael; Padgett, Deborah L.; Silverberg, Steven M.; Wisniewski, John P.; Bans, Alissa S.; Bhattacharjee, Shambo; Kenyon, Scott J.; Debes, John H.; Currie, Thayne; García, Luciano; Jung, Dawoon; Lintott, Chris; Rebull, Luisa M.; Nesvold, Erika

    2016-01-01

    The Disk Detective citizen science project aims to find new stars with 22 μ m excess emission from circumstellar dust using data from NASA’s Wide-field Infrared Survey Explorer ( WISE ) mission. Initial cuts on the AllWISE catalog provide an input catalog of 277,686 sources. Volunteers then view images of each source online in 10 different bands to identify false positives (galaxies, interstellar matter, image artifacts, etc.). Sources that survive this online vetting are followed up with spectroscopy on the FLWO Tillinghast telescope. This approach should allow us to unleash the full potential of WISE for finding new debris disks and protoplanetary disks. We announce a first list of 37 new disk candidates discovered by the project, and we describe our vetting and follow-up process. One of these systems appears to contain the first debris disk discovered around a star with a white dwarf companion: HD 74389. We also report four newly discovered classical Be stars (HD 6612, HD 7406, HD 164137, and HD 218546) and a new detection of 22 μ m excess around the previously known debris disk host star HD 22128.

  14. Disk Detective: Discovery of New Circumstellar Disk Candidates Through Citizen Science

    Science.gov (United States)

    Kuchner, Marc J.; Silverberg, Steven M.; Bans, Alissa S.; Bhattacharjee, Shambo; Kenyon, Scott J.; Debes, John H.; Currie, Thayne; Garcia, Luciano; Jung, Dawoon; Lintott, Chris; hide

    2016-01-01

    The Disk Detective citizen science project aims to find new stars with 22 micron excess emission from circumstellar dust using data from NASAs Wide-field Infrared Survey Explorer (WISE) mission. Initial cuts on the AllWISE catalog provide an input catalog of 277,686 sources. Volunteers then view images of each source online in 10different bands to identify false positives (galaxies, interstellar matter, image artifacts, etc.). Sources that survive this online vetting are followed up with spectroscopy on the FLWO Tillinghast telescope. This approach should allow us to unleash the full potential of WISE for finding new debris disks and proto planetary disks. We announce a first list of 37 new disk candidates discovered by the project, and we describe our vetting and follow-up process. One of these systems appears to contain the first debris disk discovered around a star with a white dwarf companion: HD 74389. We also report four newly discovered classical Be stars (HD 6612, HD 7406, HD 164137,and HD 218546) and a new detection of 22 micron excess around the previously known debris disk host star HD 22128.

  15. A Third-Generation Adaptive Statistical Iterative Reconstruction Technique: Phantom Study of Image Noise, Spatial Resolution, Lesion Detectability, and Dose Reduction Potential.

    Science.gov (United States)

    Euler, André; Solomon, Justin; Marin, Daniele; Nelson, Rendon C; Samei, Ehsan

    2018-06-01

    The purpose of this study was to assess image noise, spatial resolution, lesion detectability, and the dose reduction potential of a proprietary third-generation adaptive statistical iterative reconstruction (ASIR-V) technique. A phantom representing five different body sizes (12-37 cm) and a contrast-detail phantom containing lesions of five low-contrast levels (5-20 HU) and three sizes (2-6 mm) were deployed. Both phantoms were scanned on a 256-MDCT scanner at six different radiation doses (1.25-10 mGy). Images were reconstructed with filtered back projection (FBP), ASIR-V with 50% blending with FBP (ASIR-V 50%), and ASIR-V without blending (ASIR-V 100%). In the first phantom, noise properties were assessed by noise power spectrum analysis. Spatial resolution properties were measured by use of task transfer functions for objects of different contrasts. Noise magnitude, noise texture, and resolution were compared between the three groups. In the second phantom, low-contrast detectability was assessed by nine human readers independently for each condition. The dose reduction potential of ASIR-V was estimated on the basis of a generalized linear statistical regression model. On average, image noise was reduced 37.3% with ASIR-V 50% and 71.5% with ASIR-V 100% compared with FBP. ASIR-V shifted the noise power spectrum toward lower frequencies compared with FBP. The spatial resolution of ASIR-V was equivalent or slightly superior to that of FBP, except for the low-contrast object, which had lower resolution. Lesion detection significantly increased with both ASIR-V levels (p = 0.001), with an estimated radiation dose reduction potential of 15% ± 5% (SD) for ASIR-V 50% and 31% ± 9% for ASIR-V 100%. ASIR-V reduced image noise and improved lesion detection compared with FBP and had potential for radiation dose reduction while preserving low-contrast detectability.

  16. Autofluorescence of pigmented skin lesions using a pulsed UV laser with synchronized detection: clinical results

    Science.gov (United States)

    Cheng, Haynes P. H.; Svenmarker, Pontus; Xie, Haiyan; Tidemand-Lichtenberg, Peter; Jensen, Ole B.; Bendsoe, Niels; Svanberg, Katarina; Petersen, Paul Michael; Pedersen, Christian; Andersson-Engels, Stefan; Andersen, Peter E.

    2010-04-01

    We report preliminary clinical results of autofluorescence imaging of malignant and benign skin lesions, using pulsed 355 nm laser excitation with synchronized detection. The novel synchronized detection system allows high signal-tonoise ratio to be achieved in the resulting autofluorescence signal, which may in turn produce high contrast images that improve diagnosis, even in the presence of ambient room light. The synchronized set-up utilizes a compact, diode pumped, pulsed UV laser at 355 nm which is coupled to a CCD camera and a liquid crystal tunable filter. The excitation and image capture is sampled at 5 kHz and the resulting autofluorescence is captured with the liquid crystal filter cycling through seven wavelengths between 420 nm and 580 nm. The clinical study targets pigmented skin lesions and evaluates the prospects of using autofluorescence as a possible means in differentiating malignant and benign skin tumors. Up to now, sixteen patients have participated in the clinical study. The autofluorescence images, averaged over the exposure time of one second, will be presented along with histopathological results. Initial survey of the images show good contrast and diagnostic results show promising agreement based on the histopathological results.

  17. Dissociation of Detection and Discrimination of Pure Tones following Bilateral Lesions of Auditory Cortex

    Science.gov (United States)

    Dykstra, Andrew R.; Koh, Christine K.; Braida, Louis D.; Tramo, Mark Jude

    2012-01-01

    It is well known that damage to the peripheral auditory system causes deficits in tone detection as well as pitch and loudness perception across a wide range of frequencies. However, the extent to which to which the auditory cortex plays a critical role in these basic aspects of spectral processing, especially with regard to speech, music, and environmental sound perception, remains unclear. Recent experiments indicate that primary auditory cortex is necessary for the normally-high perceptual acuity exhibited by humans in pure-tone frequency discrimination. The present study assessed whether the auditory cortex plays a similar role in the intensity domain and contrasted its contribution to sensory versus discriminative aspects of intensity processing. We measured intensity thresholds for pure-tone detection and pure-tone loudness discrimination in a population of healthy adults and a middle-aged man with complete or near-complete lesions of the auditory cortex bilaterally. Detection thresholds in his left and right ears were 16 and 7 dB HL, respectively, within clinically-defined normal limits. In contrast, the intensity threshold for monaural loudness discrimination at 1 kHz was 6.5±2.1 dB in the left ear and 6.5±1.9 dB in the right ear at 40 dB sensation level, well above the means of the control population (left ear: 1.6±0.22 dB; right ear: 1.7±0.19 dB). The results indicate that auditory cortex lowers just-noticeable differences for loudness discrimination by approximately 5 dB but is not necessary for tone detection in quiet. Previous human and Old-world monkey experiments employing lesion-effect, neurophysiology, and neuroimaging methods to investigate the role of auditory cortex in intensity processing are reviewed. PMID:22957087

  18. Dissociation of detection and discrimination of pure tones following bilateral lesions of auditory cortex.

    Science.gov (United States)

    Dykstra, Andrew R; Koh, Christine K; Braida, Louis D; Tramo, Mark Jude

    2012-01-01

    It is well known that damage to the peripheral auditory system causes deficits in tone detection as well as pitch and loudness perception across a wide range of frequencies. However, the extent to which to which the auditory cortex plays a critical role in these basic aspects of spectral processing, especially with regard to speech, music, and environmental sound perception, remains unclear. Recent experiments indicate that primary auditory cortex is necessary for the normally-high perceptual acuity exhibited by humans in pure-tone frequency discrimination. The present study assessed whether the auditory cortex plays a similar role in the intensity domain and contrasted its contribution to sensory versus discriminative aspects of intensity processing. We measured intensity thresholds for pure-tone detection and pure-tone loudness discrimination in a population of healthy adults and a middle-aged man with complete or near-complete lesions of the auditory cortex bilaterally. Detection thresholds in his left and right ears were 16 and 7 dB HL, respectively, within clinically-defined normal limits. In contrast, the intensity threshold for monaural loudness discrimination at 1 kHz was 6.5 ± 2.1 dB in the left ear and 6.5 ± 1.9 dB in the right ear at 40 dB sensation level, well above the means of the control population (left ear: 1.6 ± 0.22 dB; right ear: 1.7 ± 0.19 dB). The results indicate that auditory cortex lowers just-noticeable differences for loudness discrimination by approximately 5 dB but is not necessary for tone detection in quiet. Previous human and Old-world monkey experiments employing lesion-effect, neurophysiology, and neuroimaging methods to investigate the role of auditory cortex in intensity processing are reviewed.

  19. Dissociation of detection and discrimination of pure tones following bilateral lesions of auditory cortex.

    Directory of Open Access Journals (Sweden)

    Andrew R Dykstra

    Full Text Available It is well known that damage to the peripheral auditory system causes deficits in tone detection as well as pitch and loudness perception across a wide range of frequencies. However, the extent to which to which the auditory cortex plays a critical role in these basic aspects of spectral processing, especially with regard to speech, music, and environmental sound perception, remains unclear. Recent experiments indicate that primary auditory cortex is necessary for the normally-high perceptual acuity exhibited by humans in pure-tone frequency discrimination. The present study assessed whether the auditory cortex plays a similar role in the intensity domain and contrasted its contribution to sensory versus discriminative aspects of intensity processing. We measured intensity thresholds for pure-tone detection and pure-tone loudness discrimination in a population of healthy adults and a middle-aged man with complete or near-complete lesions of the auditory cortex bilaterally. Detection thresholds in his left and right ears were 16 and 7 dB HL, respectively, within clinically-defined normal limits. In contrast, the intensity threshold for monaural loudness discrimination at 1 kHz was 6.5 ± 2.1 dB in the left ear and 6.5 ± 1.9 dB in the right ear at 40 dB sensation level, well above the means of the control population (left ear: 1.6 ± 0.22 dB; right ear: 1.7 ± 0.19 dB. The results indicate that auditory cortex lowers just-noticeable differences for loudness discrimination by approximately 5 dB but is not necessary for tone detection in quiet. Previous human and Old-world monkey experiments employing lesion-effect, neurophysiology, and neuroimaging methods to investigate the role of auditory cortex in intensity processing are reviewed.

  20. Far-Infrared Based Pedestrian Detection for Driver-Assistance Systems Based on Candidate Filters, Gradient-Based Feature and Multi-Frame Approval Matching.

    Science.gov (United States)

    Wang, Guohua; Liu, Qiong

    2015-12-21

    Far-infrared pedestrian detection approaches for advanced driver-assistance systems based on high-dimensional features fail to simultaneously achieve robust and real-time detection. We propose a robust and real-time pedestrian detection system characterized by novel candidate filters, novel pedestrian features and multi-frame approval matching in a coarse-to-fine fashion. Firstly, we design two filters based on the pedestrians' head and the road to select the candidates after applying a pedestrian segmentation algorithm to reduce false alarms. Secondly, we propose a novel feature encapsulating both the relationship of oriented gradient distribution and the code of oriented gradient to deal with the enormous variance in pedestrians' size and appearance. Thirdly, we introduce a multi-frame approval matching approach utilizing the spatiotemporal continuity of pedestrians to increase the detection rate. Large-scale experiments indicate that the system works in real time and the accuracy has improved about 9% compared with approaches based on high-dimensional features only.

  1. Far-Infrared Based Pedestrian Detection for Driver-Assistance Systems Based on Candidate Filters, Gradient-Based Feature and Multi-Frame Approval Matching

    Directory of Open Access Journals (Sweden)

    Guohua Wang

    2015-12-01

    Full Text Available Far-infrared pedestrian detection approaches for advanced driver-assistance systems based on high-dimensional features fail to simultaneously achieve robust and real-time detection. We propose a robust and real-time pedestrian detection system characterized by novel candidate filters, novel pedestrian features and multi-frame approval matching in a coarse-to-fine fashion. Firstly, we design two filters based on the pedestrians’ head and the road to select the candidates after applying a pedestrian segmentation algorithm to reduce false alarms. Secondly, we propose a novel feature encapsulating both the relationship of oriented gradient distribution and the code of oriented gradient to deal with the enormous variance in pedestrians’ size and appearance. Thirdly, we introduce a multi-frame approval matching approach utilizing the spatiotemporal continuity of pedestrians to increase the detection rate. Large-scale experiments indicate that the system works in real time and the accuracy has improved about 9% compared with approaches based on high-dimensional features only.

  2. The value of digital tomosynthesis of the chest as a problem-solving tool for suspected pulmonary nodules and hilar lesions detected on chest radiography.

    Science.gov (United States)

    Galea, Angela; Dubbins, Paul; Riordan, Richard; Adlan, Tarig; Roobottom, Carl; Gay, David

    2015-05-01

    To assess the capability of digital tomosynthesis (DTS) of the chest compared to a postero-anterior (PA) and lateral chest radiograph (CXR) in the diagnosis of suspected but unconfirmed pulmonary nodules and hilar lesions detected on a CXR. Computed tomography (CT) was used as the reference standard. 78 patients with suspected non-calcified pulmonary nodules or hilar lesions on their CXR were included in the study. Two radiologists, blinded to the history and CT, prospectively analysed the CXR (PA and lateral) and the DTS images using a picture archiving and communication workstation and were asked to designate one of two outcomes: true intrapulmonary lesion or false intrapulmonary lesion. A CT of the chest performed within 4 weeks of the CXR was used as the reference standard. Inter-observer agreement and time to report the modalities were calculated for CXR and DTS. There were 34 true lesions confirmed on CT, 12 were hilar lesions and 22 were peripheral nodules. Of the 44 false lesions, 37 lesions were artefactual or due to composite shadow and 7 lesions were real but extrapulmonary simulating non-calcified intrapulmonary lesions. The PA and lateral CXR correctly classified 39/78 (50%) of the lesions, this improved to 75/78 (96%) with DTS. The sensitivity and specificity was 0.65 and 0.39 for CXR and 0.91 and 1 for DTS. Based on the DTS images, readers correctly classified all the false lesions but missed 3/34 true lesions. Two of the missed lesions were hilar in location and one was a peripheral nodule. All three missed lesions were incorrectly classified on DTS as composite shadow. DTS improves diagnostic confidence when compared to a repeat PA and lateral CXR in the diagnosis of both suspected hilar lesions and pulmonary nodules detected on CXR. DTS is able to exclude most peripheral pulmonary nodules but caution and further studies are needed to assess its ability to exclude hilar lesions. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. A New M Dwarf Debris Disk Candidate in a Young Moving Group Discovered with Disk Detective

    Science.gov (United States)

    Silverberg, Steven M.; Kuchner, Marc J.; Wisniewski, John P.; Gagne, Jonathan; Bans, Alissa S.; Bhattacharjee, Shambo; Currie, Thayne R.; Debes, John R.; Biggs, Joseph R; Bosch, Milton

    2016-01-01

    We used the Disk Detective citizen science project and the BANYAN II Bayesian analysis tool to identify a new candidate member of a nearby young association with infrared excess. WISE J080822.18-644357.3, an M5.5-type debris disk system with significant excess at both 12 and 22 microns, is a likely member (approx.90% BANYAN II probability) of the approx.45 Myr old Carina association. Since this would be the oldest M dwarf debris disk detected in a moving group, this discovery could be an important constraint on our understanding of M dwarf debris disk evolution.

  4. Comparision between biphasic helical CT and dynamic gadolinium-enhanced MR in the detection and characterization of focal hepatic lesions in cirrhotic patients; Estudio comparativo entre TC helicoidal bifasica y RM dinamica con gadolinio en la deteccion y caracterizacion de lesiones focales hepticas en pacientes cirrticos

    Energy Technology Data Exchange (ETDEWEB)

    Puig, J; Martn, J; Donoso, L; Falco, J; Rue, M [Consorcio Hospitalario del Parc Taul. Sabadell. Barcelona (Spain)

    1998-12-31

    To assess the agreement between biphasic helical computerized tomography (BHCT) and dynamic gadolinium-enhanced magnetic resonance (MR) in the detection and characterization of focal hepatic lesions in a group of cirrhotic patients. A prospective study was done in 50 cirrhotic patients suspected of having hepatocarcinoma (HC) on the basis of ultrasonographic images evaluated by means of BHCT and dynamic gadolinium-enhanced MR using fast low-angle shot (FLASH) sequences (110-135/4/90 degree centigree). The images were assessed jointly by four radiologists. Between the two techniques, a total of 83 lesions were detected. MR disclosed more lesions (n=79) than BHCT (n=67) (p<0.005). Moreover, 25 of the lesions that were visible by both techniques were more clearly evident in MR images (p<0.01). MR correctly classified 6 of 7 benign lesions (85%) and 49 of 66 malignant ones (74%). BHCT correctly classifed 2 of 7 benign lesions (28%) and 32 of 66 malignant ones (48%). The sensitivities of MR and BHCT for the characterization of these lesions were 74% and 48%, respectively (p=0.0009), while the respective specificities were 86% and 29% (P<0.001). Dynamic gadolinium-enhanced MR with FLASH sequences is more efficient than BHCT in the detection and characterization of focal lesions in cirrhotic patients. (Author) 37 refs.

  5. Utility of fractional anisotropy imaging analyzed by statistical parametric mapping for detecting minute brain lesions in chronic-stage patients who had mild or moderate traumatic brain injury

    International Nuclear Information System (INIS)

    Asano, Yoshitaka; Shinoda, Jun; Okumura, Ayumi; Aki, Tatsuki; Takenaka, Shunsuke; Miwa, Kazuhiro; Yamada, Mikito; Ito, Takeshi; Yokohama, Kazutoshi

    2012-01-01

    Diffusion tensor imaging (DTI) has recently evolved as valuable technique to investigate diffuse axonal injury (DAI). This study examined whether fractional anisotropy (FA) images analyzed by statistical parametric mapping (FA-SPM images) are superior to T 2 *-weighted gradient recalled echo (T2*GRE) images or fluid-attenuated inversion recovery (FLAIR) images for detecting minute lesions in traumatic brain injury (TBI) patients. DTI was performed in 25 patients with cognitive impairments in the chronic stage after mild or moderate TBI. The FA maps obtained from the DTI were individually compared with those from age-matched healthy control subjects using voxel-based analysis and FA-SPM images (p<0.001). Abnormal low-intensity areas on T2*GRE images (T2* lesions) were found in 10 patients (40.0%), abnormal high-intensity areas on FLAIR images in 4 patients (16.0%), and areas with significantly decreased FA on FA-SPM image in 16 patients (64.0%). Nine of 10 patients with T2* lesions had FA-SPM lesions. FA-SPM lesions topographically included most T2* lesions in the white matter and the deep brain structures, but did not include T2* lesions in the cortex/near-cortex or lesions containing substantial hemosiderin regardless of location. All 4 patients with abnormal areas on FLAIR images had FA-SPM lesions. FA-SPM imaging is useful for detecting minute lesions because of DAI in the white matter and the deep brain structures, which may not be visualized on T2*GRE or FLAIR images, and may allow the detection of minute brain lesions in patients with post-traumatic cognitive impairment. (author)

  6. Detection of magnetized quark-nuggets, a candidate for dark matter.

    Science.gov (United States)

    VanDevender, J Pace; VanDevender, Aaron P; Sloan, T; Swaim, Criss; Wilson, Peter; Schmitt, Robert G; Zakirov, Rinat; Blum, Josh; Cross, James L; McGinley, Niall

    2017-08-18

    Quark nuggets are theoretical objects composed of approximately equal numbers of up, down, and strange quarks and are also called strangelets and nuclearites. They have been proposed as a candidate for dark matter, which constitutes ~85% of the universe's mass and which has been a mystery for decades. Previous efforts to detect quark nuggets assumed that the nuclear-density core interacts directly with the surrounding matter so the stopping power is minimal. Tatsumi found that quark nuggets could well exist as a ferromagnetic liquid with a ~10 12 -T magnetic field. We find that the magnetic field produces a magnetopause with surrounding plasma, as the earth's magnetic field produces a magnetopause with the solar wind, and substantially increases their energy deposition rate in matter. We use the magnetopause model to compute the energy deposition as a function of quark-nugget mass and to analyze testing the quark-nugget hypothesis for dark matter by observations in air, water, and land. We conclude the water option is most promising.

  7. Toward Detection of Exoplanetary Rings via Transit Photometry: Methodology and a Possible Candidate

    Energy Technology Data Exchange (ETDEWEB)

    Aizawa, Masataka; Masuda, Kento; Suto, Yasushi [Department of Physics, The University of Tokyo, Tokyo, 113-0033 (Japan); Uehara, Sho [Department of Physics, Tokyo Metropolitan University, Tokyo 192-4397 (Japan); Kawahara, Hajime, E-mail: aizawa@utap.phys.s.u-tokyo.ac.jp [Department of Earth and Planetary Science, The University of Tokyo, Tokyo 113-0033 (Japan)

    2017-04-01

    The detection of a planetary ring of exoplanets remains one of the most attractive, but challenging, goals in the field of exoplanetary science. We present a methodology that implements a systematic search for exoplanetary rings via transit photometry of long-period planets. This methodology relies on a precise integration scheme that we develop to compute a transit light curve of a ringed planet. We apply the methodology to 89 long-period planet candidates from the Kepler data so as to estimate, and/or set upper limits on, the parameters of possible rings. While the majority of our samples do not have sufficient signal-to-noise ratios (S/Ns) to place meaningful constraints on ring parameters, we find that six systems with higher S/Ns are inconsistent with the presence of a ring larger than 1.5 times the planetary radius, assuming a grazing orbit and a tilted ring. Furthermore, we identify five preliminary candidate systems whose light curves exhibit ring-like features. After removing four false positives due to the contamination from nearby stars, we identify KIC 10403228 as a reasonable candidate for a ringed planet. A systematic parameter fit of its light curve with a ringed planet model indicates two possible solutions corresponding to a Saturn-like planet with a tilted ring. There also remain two other possible scenarios accounting for the data; a circumstellar disk and a hierarchical triple. Due to large uncertain factors, we cannot choose one specific model among the three.

  8. Unenhanced breast MRI (STIR, T2-weighted TSE, DWIBS): An accurate and alternative strategy for detecting and differentiating breast lesions.

    Science.gov (United States)

    Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato Antonio; Angelelli, Giuseppe; Moschetta, Marco

    2015-10-01

    To assess the role of STIR, T2-weighted TSE and DWIBS sequences for detecting and characterizing breast lesions and to compare unenhanced (UE)-MRI results with contrast-enhanced (CE)-MRI and histological findings, having the latter as the reference standard. Two hundred eighty consecutive patients (age range, 27-73 years; mean age±standard deviation (SD), 48.8±9.8years) underwent MR examination with a diagnostic protocol including STIR, T2-weighted TSE, THRIVE and DWIBS sequences. Two radiologists blinded to both dynamic sequences and histological findings evaluated in consensus STIR, T2-weighted TSE and DWIBS sequences and after two weeks CE-MRI images searching for breast lesions. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy for UE-MRI and CE-MRI were calculated. UE-MRI results were also compared with CE- MRI. UE-MRI sequences obtained sensitivity, specificity, diagnostic accuracy, PPV and NPV values of 94%, 79%, 86%, 79% and 94%, respectively. CE-MRI sequences obtained sensitivity, specificity, diagnostic accuracy, PPV and NPV values of 98%, 83%, 90%, 84% and 98%, respectively. No statistically significant difference between UE-MRI and CE-MRI was found. Breast UE-MRI could represent an accurate diagnostic tool and a valid alternative to CE-MRI for evaluating breast lesions. STIR and DWIBS sequences allow to detect breast lesions while T2-weighted TSE sequences and ADC values could be useful for lesion characterization. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Is a single direct MR arthrography series in ABER position as accurate in detecting anteroinferior labroligamentous lesions as conventional MR arthography?

    Energy Technology Data Exchange (ETDEWEB)

    Schreinemachers, Saskia A.; Hulst, Victor P.M. van der; Woude, Henk-Jan van der [Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Jaap Willems, W. [Onze Lieve Vrouwe Gasthuis, Orthopaedic Surgery, Amsterdam (Netherlands); Bipat, Shandra [University of Amsterdam, Department of Radiology, Academic Medical Centre, Amsterdam (Netherlands)

    2009-07-15

    The purpose of this study is to retrospectively compare accuracy of single magnetic resonance (MR) arthrography series in Abduction External Rotation (ABER) with conventional MR arthrography for detection and characterisation of anteroinferior labroligamentous lesions, with arthroscopy as reference standard. Inter-observer variability of both protocols was determined. Institutional review board approval was obtained; informed consent was waived. MR arthrograms, including oblique axial fat suppressed T1-weighted images in ABER position and conventional imaging directions of 250 patients (170 men, 80 women; mean age, 36 years), were retrospectively and independently evaluated by three reviewers. Reviewers were blinded to clinical information and arthroscopic results. Labroligamentous lesions were registered in both ABER and MRa. The lesions were sub-classified (Bankart, Perthes, anterior labrum periosteal sleeve avulsion (ALPSA) or lesions not otherwise specified). Inter-observer agreement was assessed by Kappa statistics for all 250 patients. Ninety-two of 250 patients underwent arthroscopy. Sensitivity, specificity and accuracy of ABER versus conventional MR arthrography were calculated and compared using paired McNemar test. Kappa values of the ABER and conventional MR arthrography ranged from 0.44 to 0.56 and 0.44 to 0.62, respectively. According to arthroscopy, 45 of 92 patients had an intact anteroinferior labrum, and in 44 patients, a labroligamentous lesion (eight Bankart, seven Perthes, 29 ALPSA and three lesions not otherwise specified) was diagnosed. There were no statistically significant differences between ABER and conventional MR arthrography regarding sensitivity (85-89%, 89-96%), specificity (82-91%, 84-89%) and overall accuracy (50-62%, 53-63%). The results of a single MR arthrography series in ABER position are comparable with those of conventional MR arthrography for detecting anteroinferior labroligamentous lesions. (orig.)

  10. Skin lesion-associated pathogens from Octopus vulgaris: first detection of Photobacterium swingsii, Lactococcus garvieae and betanodavirus.

    Science.gov (United States)

    Fichi, G; Cardeti, G; Perrucci, S; Vanni, A; Cersini, A; Lenzi, C; De Wolf, T; Fronte, B; Guarducci, M; Susini, F

    2015-07-23

    The common octopus Octopus vulgaris Cuvier, 1798 is extremely important in fisheries and is a useful protein source in most Mediterranean countries. Here we investigated pathogens associated with skin lesions in 9 naturally deceased specimens that included both cultured and wild common octopus. Within 30 min after death, each octopus was stored at 4°C and microbiologically examined within 24 h. Bacterial colonies, cultured from swabs taken from the lesions, were examined using taxonomical and biochemical analyses. Vibrio alginolyticus and V. parahaemolyticus were only isolated from cultured animals. A conventional PCR targeting the 16S ribosomal RNA (rRNA) gene and sequencing were performed on 2 bacterial isolates that remained unidentified after taxonomical and biochemical analysis. The sequence results indicated that the bacteria had a 99% identity with Lactococcus garvieae and Photobacterium swingsii. L. garvieae was confirmed using a specific PCR based on the 16S-23S rRNA internal transcribed spacer region, while P. swingsii was confirmed by phylogenetic analyses. Although all animals examined were found to be infected by the protozoan species Aggregata octopiana localised in the intestines, it was also present in skin lesions of 2 of the animals. Betanodavirus was detected in both cultured and wild individuals by cell culture, PCR and electron microscopy. These findings are the first report of L. garvieae and betanodavirus from skin lesions of common octopus and the first identification of P. swingsii both in octopus skin lesions and in marine invertebrates in Italy.

  11. Automatic Microaneurysms Detection Based on Multifeature Fusion Dictionary Learning

    Directory of Open Access Journals (Sweden)

    Wei Zhou

    2017-01-01

    Full Text Available Recently, microaneurysm (MA detection has attracted a lot of attention in the medical image processing community. Since MAs can be seen as the earliest lesions in diabetic retinopathy, their detection plays a critical role in diabetic retinopathy diagnosis. In this paper, we propose a novel MA detection approach named multifeature fusion dictionary learning (MFFDL. The proposed method consists of four steps: preprocessing, candidate extraction, multifeature dictionary learning, and classification. The novelty of our proposed approach lies in incorporating the semantic relationships among multifeatures and dictionary learning into a unified framework for automatic detection of MAs. We evaluate the proposed algorithm by comparing it with the state-of-the-art approaches and the experimental results validate the effectiveness of our algorithm.

  12. Towards optical spectroscopic anatomical mapping (OSAM) for lesion validation in cardiac tissue (Conference Presentation)

    Science.gov (United States)

    Singh-Moon, Rajinder P.; Zaryab, Mohammad; Hendon, Christine P.

    2017-02-01

    Electroanatomical mapping (EAM) is an invaluable tool for guiding cardiac radiofrequency ablation (RFA) therapy. The principle roles of EAM is the identification of candidate ablation sites by detecting regions of abnormal electrogram activity and lesion validation subsequent to RF energy delivery. However, incomplete lesions may present interim electrical inactivity similar to effective treatment in the acute setting, despite efforts to reveal them with pacing or drugs, such as adenosine. Studies report that the misidentification and recovery of such lesions is a leading cause of arrhythmia recurrence and repeat procedures. In previous work, we demonstrated spectroscopic characterization of cardiac tissues using a fiber optic-integrated RF ablation catheter. In this work, we introduce OSAM (optical spectroscopic anatomical mapping), the application of this spectroscopic technique to obtain 2-dimensional biodistribution maps. We demonstrate its diagnostic potential as an auxiliary method for lesion validation in treated swine preparations. Endocardial lesion sets were created on fresh swine cardiac samples using a commercial RFA system. An optically-integrated catheter console fabricated in-house was used for measurement of tissue optical spectra between 600-1000nm. Three dimensional, Spatio-spectral datasets were generated by raster scanning of the optical catheter across the treated sample surface in the presence of whole blood. Tissue optical parameters were recovered at each spatial position using an inverse Monte Carlo method. OSAM biodistribution maps showed stark correspondence with gross examination of tetrazolium chloride stained tissue specimens. Specifically, we demonstrate the ability of OSAM to readily distinguish between shallow and deeper lesions, a limitation faced by current EAM techniques. These results showcase the OSAMs potential for lesion validation strategies for the treatment of cardiac arrhythmias.

  13. The value of digital tomosynthesis of the chest as a problem-solving tool for suspected pulmonary nodules and hilar lesions detected on chest radiography

    Energy Technology Data Exchange (ETDEWEB)

    Galea, Angela, E-mail: galeaangie@gmail.com [Peninsula Radiology Academy, William Prance Road, Plymouth PL65WR (United Kingdom); Dubbins, Paul, E-mail: Paul.dubbins@nhs.net [Plymouth Hospital NHS Trust, Plymouth PL68DH (United Kingdom); Riordan, Richard, E-mail: richardriordan@nhs.net [Plymouth Hospital NHS Trust, Plymouth PL68DH (United Kingdom); Adlan, Tarig, E-mail: tarig.adlan@nhs.net [Plymouth Hospital NHS Trust, Plymouth PL68DH (United Kingdom); Roobottom, Carl, E-mail: carl.roobotoom@nhs.net [Plymouth Hospital NHS Trust, Plymouth PL68DH (United Kingdom); Gay, David, E-mail: davegay@nhs.net [Plymouth Hospital NHS Trust, Plymouth PL68DH (United Kingdom)

    2015-05-15

    Graphical abstract: When compared to CXR, DTS has: • Superior resolution • Better assessment of location in the AP dimension (better at locating a pleural or intrapulmonary lesion) • Better characterisation (better at distinguishing between calcified plaque and soft tissue) • Removes composite artefact caused by overlying anatomical structures (such as the ribs or pulmonary vessels) DTS has improved sensitivity, specificity and accuracy when compared to CXR. - Highlights: • DTS is a type of limited angle tomography. Sixty coronal reconstructed images of the chest are produced that combine the superior resolution of radiography with the tomographic benefits of computed tomography. • The sensitivity for detecting a suspected lung lesions is 0.65 with CXR and 0.91 for DTS. • The high specificity of DTS (1) and the high negative predictive value (0.94) are similar to CT and suggest that if the DTS is normal patients do not need further assessment with CT with significant potential dose savings. • 50% of suspected lesions were resolved with CXR, this improved to 96% with DTS. - Abstract: Objectives: To assess the capability of digital tomosynthesis (DTS) of the chest compared to a postero-anterior (PA) and lateral chest radiograph (CXR) in the diagnosis of suspected but unconfirmed pulmonary nodules and hilar lesions detected on a CXR. Computed tomography (CT) was used as the reference standard. Materials and method: 78 patients with suspected non-calcified pulmonary nodules or hilar lesions on their CXR were included in the study. Two radiologists, blinded to the history and CT, prospectively analysed the CXR (PA and lateral) and the DTS images using a picture archiving and communication workstation and were asked to designate one of two outcomes: true intrapulmonary lesion or false intrapulmonary lesion. A CT of the chest performed within 4 weeks of the CXR was used as the reference standard. Inter-observer agreement and time to report the modalities

  14. The value of digital tomosynthesis of the chest as a problem-solving tool for suspected pulmonary nodules and hilar lesions detected on chest radiography

    International Nuclear Information System (INIS)

    Galea, Angela; Dubbins, Paul; Riordan, Richard; Adlan, Tarig; Roobottom, Carl; Gay, David

    2015-01-01

    Graphical abstract: When compared to CXR, DTS has: • Superior resolution • Better assessment of location in the AP dimension (better at locating a pleural or intrapulmonary lesion) • Better characterisation (better at distinguishing between calcified plaque and soft tissue) • Removes composite artefact caused by overlying anatomical structures (such as the ribs or pulmonary vessels) DTS has improved sensitivity, specificity and accuracy when compared to CXR. - Highlights: • DTS is a type of limited angle tomography. Sixty coronal reconstructed images of the chest are produced that combine the superior resolution of radiography with the tomographic benefits of computed tomography. • The sensitivity for detecting a suspected lung lesions is 0.65 with CXR and 0.91 for DTS. • The high specificity of DTS (1) and the high negative predictive value (0.94) are similar to CT and suggest that if the DTS is normal patients do not need further assessment with CT with significant potential dose savings. • 50% of suspected lesions were resolved with CXR, this improved to 96% with DTS. - Abstract: Objectives: To assess the capability of digital tomosynthesis (DTS) of the chest compared to a postero-anterior (PA) and lateral chest radiograph (CXR) in the diagnosis of suspected but unconfirmed pulmonary nodules and hilar lesions detected on a CXR. Computed tomography (CT) was used as the reference standard. Materials and method: 78 patients with suspected non-calcified pulmonary nodules or hilar lesions on their CXR were included in the study. Two radiologists, blinded to the history and CT, prospectively analysed the CXR (PA and lateral) and the DTS images using a picture archiving and communication workstation and were asked to designate one of two outcomes: true intrapulmonary lesion or false intrapulmonary lesion. A CT of the chest performed within 4 weeks of the CXR was used as the reference standard. Inter-observer agreement and time to report the modalities

  15. Value of fat-suppressed PD-weighted TSE-sequences for detection of anterior and posterior cruciate ligament lesions-Comparison to arthroscopy

    International Nuclear Information System (INIS)

    Schaefer, Fritz K.W.; Schaefer, Philipp J.; Brossmann, Joachim; Frahm, Christian; Muhle, Claus; Hilgert, Ralf Erik; Heller, Martin; Jahnke, Thomas

    2006-01-01

    Objective: To evaluate fat-suppressed (FS) proton-density-weighted (PDw) turbo spin-echo (TSE) magnetic resonance imaging for the detection of anterior and posterior cruciate ligament lesions in comparison to arthroscopy. Materials and methods: In a prospective study 31 knee joints were imaged on a 1.5 T MR scanner (Vision[reg], Siemens, Erlangen) prior to arthroscopy using following sequences: (a) sagittal FS-PDw/T2w TSE (TR/TE: 4009/15/105 ms); (b) sagittal PDw/T2w TSE (TR/TE:3800/15/105 ms). Further imaging parameters: slice thickness 3 mm, FOV 160 mm, matrix 256 x 256. A total of 62 anterior and posterior cruciate ligaments (ACL/PCL) were evaluated, standard of reference was arthroscopy. Sensitivity, specificity, positive (ppv) and negative predictive value (npv) and accuracy were calculated. Results: Twenty-one cruciate ligament ruptures were detected in arthroscopy, 19 ACL- and 2 PCL-ruptures (on MRI 34/124, 25/62 ACL, 9/62 PCL lesions). For all four sequences in the 31 patients with arthroscopic correlation sensitivity, specificity, ppv, npv and accuracy were 86%, 98%, 95%, 93% and 94% for detection of tears, and 84%, 100%, 100%, 80% and 90% for ACL-ruptures respectively. The two PCL-ruptures were true positive in all sequences, one intact PCL was diagnosed as torn (false positive). Conclusions: Fat-suppressed PDw/T2w TSE-MR sequences are comparable to PDw TSE sequences for the detection of ACL/PCL-lesions

  16. Detection of up to 65% of Precancerous Lesions of the Human Colon and Rectum by Mutation Analysis of APC, K-Ras, B-Raf and CTNNB1

    International Nuclear Information System (INIS)

    Schneider, Mandy; Scholtka, Bettina; Gottschalk, Uwe; Faiss, Siegbert; Schatz, Daniela; Berghof-Jäger, Kornelia; Steinberg, Pablo

    2010-01-01

    In the present study a recently conceived 4-gene marker panel covering the Wnt and Ras-Raf-MEK-MAPK signaling pathways was used to analyze 20 colorectal serrated lesions and 41 colorectal adenoma samples and to determine the percentage of each of the above-mentioned potentially precancerous lesions carrying at least one of the four above-mentioned genes in a mutated form. CTNNB1 and B-Raf were screened by PCR-single-strand conformation polymorphism analysis, K-Ras by restriction fragment length polymorphism analysis and the APC gene mutation cluster region (codons 1243–1567) by direct DNA sequencing. APC mutations were only detected in 10% of the serrated lesions but in 34% of the adenomas. Twenty percent of the serrated lesions and 14% of the adenomas carried a mutated K-Ras. B-Raf was found to be mutated in 50% of the serrated lesions and in 22% of the adenomas. CTNNB1 was altered in 12% of the adenomas, but not in serrated lesions. By using the above gene marker panel it could be shown that 65% of the serrated lesions and 61% of the adenomas carried at least one of the four genes in a mutated form. Based on its excellent performance in detecting mutations in sporadic preneoplastic (in this study) and neoplastic lesions (in a previous study) of the human colon and rectum, this primer combination might also be suited to efficiently and non-invasively detect genetic alterations in stool DNA of patients with early colorectal cancer

  17. Detection of up to 65% of Precancerous Lesions of the Human Colon and Rectum by Mutation Analysis of APC, K-Ras, B-Raf and CTNNB1

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Mandy; Scholtka, Bettina, E-mail: scholtka@uni-potsdam.de [Chair of Nutritional Toxicology, Institute of Nutritional Science, University of Potsdam, Arthur- Scheunert-Allee 114-116, 14558 Nuthetal (Germany); Gottschalk, Uwe [Maria Heimsuchung Caritas-Klinik Pankow, Breite Straße 46/47, 13187 Berlin (Germany); Faiss, Siegbert [III. Medizinische Abteilung - Gastroenterologie und Hepatologie, Asklepios Klinik Barmbek, Rubenkamp 220, 22291 Hamburg (Germany); Schatz, Daniela; Berghof-Jäger, Kornelia [BIOTECON Diagnostics GmbH, Hermannswerder Haus 17, 14473 Potsdam (Germany); Steinberg, Pablo, E-mail: scholtka@uni-potsdam.de [Chair of Nutritional Toxicology, Institute of Nutritional Science, University of Potsdam, Arthur- Scheunert-Allee 114-116, 14558 Nuthetal (Germany); Institute for Food Toxicology and Analytical Chemistry, University of Veterinary Medicine Hannover, Bischofsholer Damm 15, 30173 Hannover (Germany)

    2010-12-29

    In the present study a recently conceived 4-gene marker panel covering the Wnt and Ras-Raf-MEK-MAPK signaling pathways was used to analyze 20 colorectal serrated lesions and 41 colorectal adenoma samples and to determine the percentage of each of the above-mentioned potentially precancerous lesions carrying at least one of the four above-mentioned genes in a mutated form. CTNNB1 and B-Raf were screened by PCR-single-strand conformation polymorphism analysis, K-Ras by restriction fragment length polymorphism analysis and the APC gene mutation cluster region (codons 1243–1567) by direct DNA sequencing. APC mutations were only detected in 10% of the serrated lesions but in 34% of the adenomas. Twenty percent of the serrated lesions and 14% of the adenomas carried a mutated K-Ras. B-Raf was found to be mutated in 50% of the serrated lesions and in 22% of the adenomas. CTNNB1 was altered in 12% of the adenomas, but not in serrated lesions. By using the above gene marker panel it could be shown that 65% of the serrated lesions and 61% of the adenomas carried at least one of the four genes in a mutated form. Based on its excellent performance in detecting mutations in sporadic preneoplastic (in this study) and neoplastic lesions (in a previous study) of the human colon and rectum, this primer combination might also be suited to efficiently and non-invasively detect genetic alterations in stool DNA of patients with early colorectal cancer.

  18. Detection of human cytomegalovirus and Epstein-Barr Virus in symptomatic and asymptomatic apical periodontitis lesions by real-time PCR.

    Science.gov (United States)

    Ozbek, Selcuk-M; Ozbek, Ahmet; Yavuz, Muhammed-Selim

    2013-09-01

    Recent studies have investigated the occurrence of human cytomegalovirus and Epstein-Barr Virus in samples from apical periodontitis lesions and a role in the pathogenesis of this disease has been suggested. Because genotype distribution and seroprevalence of EBV and HCMV differ among populations, it is important to determine the presence of these viruses in endodontic periapical lesions of different populations. The aims of this study were to determine the presence of HCMV and EBV DNAs in samples from Turkish patients with symptomatic and asymptomatic apical periodontitis lesions using real-time polymerase chain reaction method and to evaluate their presence in both symptomatic and asymptomatic apical periodontitis lesions. Periapical samples were collected from 12 asymptomatic and 16 symptomatic periapical lesions in conjunction with apicectomy. HCMV and EBV DNAs were identified in the samples by real-time PCR. The chi-squared test with Yates's correction or the Fisher's exact test was used to analyse the significance of differences. HCMV DNA was detected in 10 of the 16 (62.5%) symptomatic and in five of the 12 (41.7 %) asymptomatic periapical study lesions. The EBV DNA was identified in seven of the 16 (43.7 %) symptomatic and three of the 12 (25 %) asymptomatic periapical lesions. The difference in occurrence of HCMV and EBV DNA between symptomatic and asymptomatic periapical lesions was not statistically significant. (All comparisons have p > 0.05). Our findings suggest that HCMV and EBV is a frequent inhabitant of both symptomatic and asymptomatic apical periodontitis lesions of endodontic origin in Turkish population.

  19. Detecting ICRS grade 1 cartilage lesions in anterior cruciate ligament injury using T1ρ and T2 mapping

    Energy Technology Data Exchange (ETDEWEB)

    Nishioka, Hiroaki, E-mail: kinuhnishiok@fc.kuh.kumamoto-u.ac.jp [Department of Orthopaedic Surgery, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556 (Japan); Hirose, Jun, E-mail: hirojun-mk@umin.ac.jp [Department of Orthopaedic Surgery, Kumamoto University Hospital, 1-1-1 Honjo, Kumamoto 860-8556 (Japan); Nakamura, Eiichi, E-mail: h@kumamoto-u.ac.jp [Department of Orthopaedic Surgery, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556 (Japan); Okamoto, Nobukazu, E-mail: nobuoka9999@fc.kuh.kumamoto-u.ac.jp [Department of Orthopaedic Surgery, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556 (Japan); Karasugi, Tatsuki, E-mail: tatsukik@fc.kuh.kumamoto-u.ac.jp [Department of Orthopaedic Surgery, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556 (Japan); Taniwaki, Takuya, E-mail: takuyataniwaki@fc.kuh.kumamoto-u.ac.jp [Department of Orthopaedic Surgery, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556 (Japan); Okada, Tatsuya, E-mail: tatsuya-okada@fc.kuh.kumamoto-u.ac.jp [Department of Orthopaedic Surgery, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556 (Japan); Yamashita, Yasuyuki, E-mail: yama@kumamoto-u.ac.jp [Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556 (Japan); Mizuta, Hiroshi, E-mail: mizuta@kumamoto-u.ac.jp [Department of Orthopaedic Surgery, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556 (Japan)

    2013-09-15

    Objective: The purpose of this study was to clarify the detectability of the International Cartilage Repair Society (ICRS) grade 1 cartilage lesions in anterior cruciate ligament (ACL)–injured knees using T1ρ and T2 mapping. Materials and Methods: We performed preoperative T1ρ and T2 mapping and 3D gradient–echo with water–selective excitation (WATS) sequences on 37 subjects with ACL injuries. We determined the detectability on 3D WATS based on arthroscopic findings. The T1ρ and T2 values (ms) were measured in the regions of interest that were placed on the weight–bearing cartilage of the femoral condyle. The receiver operating characteristic (ROC) curve based on these values was constructed using the arthroscopic findings as a reference standard. The evaluation of cartilage was carried out only in the weight–bearing cartilage. The cut–off values for determining the presence of a cartilage injury were determined using each ROC curve, and the detectability was calculated for the T1ρ and T2 mapping. Results: The cut–off values for the T1ρ and T2 were 41.6 and 41.2, respectively. The sensitivity and specificity of T1ρ were 91.2% and 89.5%, respectively, while those of T2 were 76.5% and 81.6%, respectively. For the 3D WATS images, the same values were 58.8% and 78.9%, respectively. Conclusions: Our study demonstrated that the T1ρ and T2 values were significantly higher for ICRS grade 1 cartilage lesions than for normal cartilage and that the two mappings were able to non–invasively detect ICRS grade 1 cartilage lesions in the ACL–injured knee with a higher detectability than were 3D WATS images.

  20. MOA-2010-BLG-311: A PLANETARY CANDIDATE BELOW THE THRESHOLD OF RELIABLE DETECTION

    International Nuclear Information System (INIS)

    Yee, J. C.; Hung, L.-W.; Gould, A.; Gaudi, B. S.; Bond, I. A.; Allen, W.; Monard, L. A. G.; Albrow, M. D.; Fouqué, P.; Dominik, M.; Tsapras, Y.; Udalski, A.; Zellem, R.; Bos, M.; Christie, G. W.; DePoy, D. L.; Dong, Subo; Drummond, J.; Gorbikov, E.; Han, C.

    2013-01-01

    We analyze MOA-2010-BLG-311, a high magnification (A max > 600) microlensing event with complete data coverage over the peak, making it very sensitive to planetary signals. We fit this event with both a point lens and a two-body lens model and find that the two-body lens model is a better fit but with only Δχ 2 ∼ 80. The preferred mass ratio between the lens star and its companion is q = 10 –3.7±0.1 , placing the candidate companion in the planetary regime. Despite the formal significance of the planet, we show that because of systematics in the data the evidence for a planetary companion to the lens is too tenuous to claim a secure detection. When combined with analyses of other high-magnification events, this event helps empirically define the threshold for reliable planet detection in high-magnification events, which remains an open question.

  1. MOA-2010-BLG-311: A PLANETARY CANDIDATE BELOW THE THRESHOLD OF RELIABLE DETECTION

    Energy Technology Data Exchange (ETDEWEB)

    Yee, J. C.; Hung, L.-W.; Gould, A.; Gaudi, B. S. [Department of Astronomy, Ohio State University, 140 West 18th Avenue, Columbus, OH 43210 (United States); Bond, I. A. [Institute for Information and Mathematical Sciences, Massey University, Private Bag 102-904, Auckland 1330 (New Zealand); Allen, W. [Vintage Lane Observatory, Blenheim (New Zealand); Monard, L. A. G. [Bronberg Observatory, Centre for Backyard Astrophysics, Pretoria (South Africa); Albrow, M. D. [Department of Physics and Astronomy, University of Canterbury, Private Bag 4800, Christchurch 8020 (New Zealand); Fouque, P. [IRAP, CNRS, Universite de Toulouse, 14 avenue Edouard Belin, F-31400 Toulouse (France); Dominik, M. [SUPA, University of St. Andrews, School of Physics and Astronomy, North Haugh, St. Andrews, KY16 9SS (United Kingdom); Tsapras, Y. [Las Cumbres Observatory Global Telescope Network, 6740B Cortona Drive, Goleta, CA 93117 (United States); Udalski, A. [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland); Zellem, R. [Department of Planetary Sciences/LPL, University of Arizona, 1629 East University Boulevard, Tucson, AZ 85721 (United States); Bos, M. [Molehill Astronomical Observatory, North Shore City, Auckland (New Zealand); Christie, G. W. [Auckland Observatory, P.O. Box 24-180, Auckland (New Zealand); DePoy, D. L. [Department of Physics, Texas A and M University, 4242 TAMU, College Station, TX 77843-4242 (United States); Dong, Subo [Institute for Advanced Study, Einstein Drive, Princeton, NJ 08540 (United States); Drummond, J. [Possum Observatory, Patutahi (New Zealand); Gorbikov, E. [School of Physics and Astronomy, Raymond and Beverley Sackler Faculty of Exact Sciences, Tel-Aviv University, Tel Aviv 69978 (Israel); Han, C., E-mail: liweih@astro.ucla.edu, E-mail: rzellem@lpl.arizona.edu, E-mail: tim.natusch@aut.ac.nz [Department of Physics, Chungbuk National University, 410 Seongbong-Rho, Hungduk-Gu, Chongju 371-763 (Korea, Republic of); Collaboration: muFUN Collaboration; MOA Collaboration; OGLE Collaboration; PLANET Collaboration; RoboNet Collaboration; MiNDSTEp Consortium; and others

    2013-05-20

    We analyze MOA-2010-BLG-311, a high magnification (A{sub max} > 600) microlensing event with complete data coverage over the peak, making it very sensitive to planetary signals. We fit this event with both a point lens and a two-body lens model and find that the two-body lens model is a better fit but with only {Delta}{chi}{sup 2} {approx} 80. The preferred mass ratio between the lens star and its companion is q = 10{sup -3.7{+-}0.1}, placing the candidate companion in the planetary regime. Despite the formal significance of the planet, we show that because of systematics in the data the evidence for a planetary companion to the lens is too tenuous to claim a secure detection. When combined with analyses of other high-magnification events, this event helps empirically define the threshold for reliable planet detection in high-magnification events, which remains an open question.

  2. Experimental phantom lesion detectability study using a digital breast tomosynthesis prototype system

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Wenkel, E.; Lell, M.; Boehner, C.; Bautz, W.A.; Mertelmeier, T.

    2006-01-01

    Purpose: To compare the sensitivity of conventional two-dimensional (2D) projection imaging with tomosynthesis with respect to the detectability of mammographic phantom lesions. Materials and Methods: Using a breast tomosynthesis prototype based on a commercial FFDM system (Siemens MAMMOMAT Novation DR ), but modified for a wide angle tube motion and equipped with a fast read-out amorphous selenium detector, we acquired standard 2D images and tomosynthesis series of projection views. We used the Wisconsin mammographic random phantom, model RMI 152A. The anode filter combinations Mo/Mo and W/Rh at two different doses were used as typical radiographic techniques. Slice images through the phantom parallel to the detector were reconstructed with a distance of 1 mm employing a filtered back-projection algorithm. The image data sets were read by five radiologists and evaluated with respect to the detectability of the phantom details. Results: For all studied radiographic techniques, the detection rate in the tomosynthesis mode was 100%, i.e. 75 true positive findings out of 75 possible hits. In contrast, the conventional projection mode yielded a detection rate between 80 and 93% (corresponding to 60 and 70 detected details) depending on the dose and X-ray spectrum. Conclusion: Tomosynthesis has the potential to increase the sensitivity of digital mammography. Overlapping structures from out-of-plane tissue can be removed in the tomosynthesis reconstruction process, thereby enhancing the diagnostic accuracy. (orig.)

  3. An object-based approach for detecting small brain lesions: application to Virchow-Robin spaces.

    Science.gov (United States)

    Descombes, Xavier; Kruggel, Frithjof; Wollny, Gert; Gertz, Hermann Josef

    2004-02-01

    This paper is concerned with the detection of multiple small brain lesions from magnetic resonance imaging (MRI) data. A model based on the marked point process framework is designed to detect Virchow-Robin spaces (VRSs). These tubular shaped spaces are due to retraction of the brain parenchyma from its supplying arteries. VRS are described by simple geometrical objects that are introduced as small tubular structures. Their radiometric properties are embedded in a data term. A prior model includes interactions describing the clustering property of VRS. A Reversible Jump Markov Chain Monte Carlo algorithm (RJMCMC) optimizes the proposed model, obtained by multiplying the prior and the data model. Example results are shown on T1-weighted MRI datasets of elderly subjects.

  4. ROC evaluation of SPECT myocardial lesion detectability with and without single iteration non-uniform Chang attenuation compensation using an anthropomorphic female phantom

    International Nuclear Information System (INIS)

    Jang, S.; Jaszczak, R.J.; Duke Univ. Medical Center, Durham, NC; Gilland, D.R.; Turkington, T.G.; Coleman, R.E.; Tsui, B.M.W.; Metz, C.E.

    1998-01-01

    The purpose of this work was to evaluate lesion detectability with and without nonuniform attenuation compensation (AC) in myocardial perfusion SPECT imaging in women using an anthropomorphic phantom and receiver operating characteristics (ROC) methodology. Breast attenuation causes artifacts in reconstructed images and may increase the difficulty of diagnosis of myocardial perfusion imaging in women. The null hypothesis tested using the ROC study was that nonuniform AC does not change the lesion detectability in myocardial perfusion SPECT imaging in women. The authors used a filtered backprojection (FBP) reconstruction algorithm and Chang's single iteration method for AC. In conclusion, with the proposed myocardial defect model nuclear medicine physicians demonstrated no significant difference for the detection of the anterior wall defect; however, a greater accuracy for the detection of the inferior wall defect was observed without nonuniform AC than with it. Medical physicists did not demonstrate any statistically significant difference in defect detection accuracy with or without nonuniform AC in the female phantom

  5. Added diagnostic value of respiratory-gated 4D 18F-FDG PET/CT in the detection of liver lesions. A multicenter study

    Energy Technology Data Exchange (ETDEWEB)

    Crivellaro, Cinzia; Landoni, Claudio; Guerra, Luca [San Gerardo Hospital, Nuclear Medicine, Monza (Italy); University of Milan-Bicocca, Milan (Italy); De Ponti, Elena; Morzenti, Sabrina [San Gerardo Hospital, Medical Physics, Monza (Italy); Elisei, Federica [San Gerardo Hospital, Nuclear Medicine, Monza (Italy); Picchio, Maria; Bettinardi, Valentino [IRCCS San Raffaele Scientific Institute, Nuclear Medicine, Milan (Italy); Versari, Annibale [Santa Maria Nuova Hospital IRCCS, Nuclear Medicine, Reggio Emilia (Italy); Fioroni, Federica [Santa Maria Nuova Hospital IRCCS, Medical Physics, Reggio Emilia (Italy); Dziuk, Miroslaw; Tkaczewski, Konrad [Military Institute of Medicine, Warsaw (Poland); Ahond-Vionnet, Renee; Nodari, Guillaume [Hopital Pierre Beregovoy, Service de Medecine Nucleaire, Nevers (France); Todde, Sergio [University of Milan-Bicocca, Tecnomed Foundation, Monza (Italy)

    2018-01-15

    The aim of the present study was to evaluate the added diagnostic value of respiratory-gated 4D18F-FDG PET/CT in liver lesion detection and characterization in a European multicenter retrospective study. Fifty-six oncological patients (29 males and 27 females, mean age, 61.2 ± 11.2 years) from five European centers, submitted to standard 3D-PET/CT and liver 4D-PET/CT were retrospectively evaluated. Based on visual analysis, liver PET/CT findings were scored as positive, negative, or equivocal both in 3D and 4D PET/CT. The impact of 4D-PET/CT on the confidence in classifying liver lesions was assessed. PET/CT findings were compared to histology and clinical follow-up as standard reference and diagnostic accuracy was calculated for both techniques. At semi-quantitative analysis, SUVmax was calculated for each detected lesion in 3D and 4D-PET/CT. Overall, 72 liver lesions were considered for the analysis. Based on visual analysis in 3D-PET/CT, 32/72 (44.4%) lesions were considered positive, 21/72 (29.2%) negative, and 19/72 (26.4%) equivocal, while in 4D-PET/CT 48/72 (66.7%) lesions were defined positive, 23/72 (31.9%) negative, and 1/72 (1.4%) equivocal. 4D-PET/CT findings increased the confidence in lesion definition in 37/72 lesions (51.4%). Considering 3D equivocal lesions as positive, sensitivity, specificity, and accuracy were 88.9, 70.0, and 83.1%, respectively, while the same figures were 67.7, 90.0, and 73.8% if 3D equivocal findings were included as negative. 4D-PET/CT sensitivity, specificity, and accuracy were 97.8, 90.0, and 95.4%, respectively, considering equivocal lesions as positive and 95.6, 90.0, and 93.8% considering equivocal lesions as negative. The SUVmax of the liver lesions in 4D-PET (mean ± SD, 6.9 ± 3.2) was significantly higher (p < 0.001) than SUVmax in 3D-PET (mean ± SD, 5.2 ± 2.3). Respiratory-gated PET/CT technique is a valuable clinical tool in diagnosing liver lesions, reducing 3D undetermined findings, improving diagnostic

  6. 18F-PET imaging: frequency, distribution and appearance of benign lesions

    International Nuclear Information System (INIS)

    Schirrmeister, H.; Kotzerke, J.; Rentschler, M.; Traeger, H.; Fenchel, S.; Diederichs, C.G.; Reske, S.N.; Nuessle, K.

    1998-01-01

    Purpose: We evaluated the frequency, distribution and appearance of benign lesions in 18 F-PET scans. Methods: Between March 1996 and May 1997, 18 F-PET scans were performed in 59 patients in addition to conventional planar bone scintigraphy. Eleven patients were subjected to additional SPECT imaging. The main indication was searching for bone metastases (58 pat.). The diagnosis was confirmed radiologically. Results: With 18 F-PET in 39 patients (66,1%) 152 benign lesions, mostly located in the spine were detected. 99m Tc bone scans revealed 45 lesions in 10 patients. Osteoarthritis of the intervertebral articulations (69%) or of the acromioclavicular joint (15%) were the most common reasons for degenerative lesions detected with 18 F-PET. Osteophytes appeared as hot lesions located at two adjacent vertebral endplates. Osteoarthritis of the intervertebral articulations showed an enhanced tracer uptake at these localizations, whereas endplate fractures of the vertebral bodies appeared very typically; solitary fractures of the ribs could not be differentiated from metastases. Rare benign lesions were not studied. Conclusion: Most of the degenerative lesions (84%) detected with 18 F-PET had a very typical appearance and could be detected with the improved spatial resolution and advantages of a tomographic technique. 18 F-PET had an increased accuracy in detecting degenerative bone lesions. (orig.) [de

  7. Candidate genes detected in transcriptome studies are strongly dependent on genetic background.

    Directory of Open Access Journals (Sweden)

    Pernille Sarup

    2011-01-01

    Full Text Available Whole genome transcriptomic studies can point to potential candidate genes for organismal traits. However, the importance of potential candidates is rarely followed up through functional studies and/or by comparing results across independent studies. We have analysed the overlap of candidate genes identified from studies of gene expression in Drosophila melanogaster using similar technical platforms. We found little overlap across studies between putative candidate genes for the same traits in the same sex. Instead there was a high degree of overlap between different traits and sexes within the same genetic backgrounds. Putative candidates found using transcriptomics therefore appear very sensitive to genetic background and this can mask or override effects of treatments. The functional importance of putative candidate genes emerging from transcriptome studies needs to be validated through additional experiments and in future studies we suggest a focus on the genes, networks and pathways affecting traits in a consistent manner across backgrounds.

  8. CT-guided preoperative needle localization of MRI-detected breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Giagounidis, Elektra M. E-mail: giagounjdis@online.de; Markus, Ruwe; Josef, Luetzeler; Wemer, Audretsch; Mahdi, Rezai; Bernward, Kurtz

    2001-08-01

    To assess the value of accurate preoperative CT-guided needle localization of occult breast lesions, we reviewed a total of 39 needle-directed biopsies of breast tumors in 24 women. The average age was 52.9 years (range 31-67). All lesions were nonpalpable and mammographically, as well as sonographically occult. They were solely seen on MR-images. After demonstrating the suspicious region on CT scans, a hookwire was inserted. The correct position was confirmed by a control scan. The subsequent histopathological examination showed that 28 of the lesions (71.8%) were benign, among them mastopathy, fibrosis, fibroadenoma, papilloma, intramammary lymph node, liponecrosis and epitheliosis. Eleven lesions (28%) were malignant and showed either lobular, ductal or tubular cancer. Our results endorse that CT guided needle localization is a helpful method that allows a precise surgical excision of the suspect area with the removal of a minimal amount of breast tissue.

  9. Characteristics, Detection Methods and Treatment of Questionable Occlusal Carious Lesions

    DEFF Research Database (Denmark)

    Makhija, S.K.; Gilbert, G.H.; Funkhouser, E.

    2014-01-01

    . The objective of this report has been to quantify the characteristics of these common lesions, the diagnostic aids used and the treatment of QOC. A total of 82 dentist and hygienist practitioner-investigators from the USA and Denmark in the National Dental Practice-Based Research Network participated. When...... consenting patients presented with a QOC, information was recorded about the patient, tooth, lesion and treatments. A total of 2,603 QOC from 1,732 patients were analyzed. The lesions were usually associated with a fissure, on molars, and varied from yellow to black in color. Half presented with a chalky...... luster and had a rough surface when examined with an explorer. There was an association between color and luster: 10% were chalky-light, 47% were shiny-dark and 42% were mixtures. A higher proportion of chalky than of shiny lesions were light (22 vs. 9%; p color were less common...

  10. Molecular detection of bacteria associated to caries activity in dentinal lesions.

    Science.gov (United States)

    Neves, Beatriz Gonçalves; Stipp, Rafael Nóbrega; da Silva Bezerra, Daniela; de Figueiredo Guedes, Sarah Florindo; Rodrigues, Lidiany Karla Azevedo

    2017-07-01

    This study aimed at identifying and quantifying Actinomyces naeslundii, Bifidobacterium spp., Streptococcus mitis group, Lactobacillus acidophilus, Lactobacillus casei group, Streptococcus gordonii, and Streptococcus mutans in active and inactive carious dentine lesions of children with early childhood caries by using quantitative polymerase chain reaction. Fifty-six dentin lesion samples, classified as active (n = 39) or inactive (n = 17), were collected from children aged from 2 to 5 years old. Dentinal-cavitated lesions were evaluated by Nyvad criteria for the assessment of caries lesion activity. Relative quantification revealed that Bifidobacterium spp. and the L. casei group were significantly more abundant in active dentin lesions (p oral microbiota related to dentin caries activity status is relevant, this study provides insights to better understand the differences in the microbiotas between active and arrested dentin cavities.

  11. Disseminated paracoccidioidomycosis diagnosis based on oral lesions

    Directory of Open Access Journals (Sweden)

    Liana Preto Webber

    2014-01-01

    Full Text Available Paracoccidioidomycosis (PCM is a deep mycosis with primary lung manifestations that may present cutaneous and oral lesions. Oral lesions mimic other infectious diseases or even squamous cell carcinoma, clinically and microscopically. Sometimes, the dentist is the first to detect the disease, because lung lesions are asymptomatic, or even misdiagnosed. An unusual case of PCM with 5 months of evolution presenting pulmonary, oral, and cutaneous lesions that was diagnosed by the dentist based on oral lesions is presented and discussed.

  12. {sup 68}Ga-DOTATATE PET/CT in recurrent medullary thyroid carcinoma: a lesion-by-lesion comparison with {sup 111}In-octreotide SPECT/CT and conventional imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yamaga, Lilian Yuri Itaya; Cunha, Marcelo L.; Campos Neto, Guilherme C.; Garcia, Marcio R.T.; Wagner, Jairo; Funari, Marcelo B.G. [Hospital Israelita Albert Einstein, Imaging Department, Sao Paulo (Brazil); Yang, Ji H.; Camacho, Cleber P. [Universidade Federal de Sao Paulo, Multiple Neoplasia Outpatiet Clinic, Sao Paulo (Brazil)

    2017-09-15

    The aim of this study was to prospectively compare the detection rate of {sup 68}Ga-DOTATATE PET-CT with {sup 111}In-octreotide SPECT-CT and conventional imaging (CI) in medullary thyroid carcinoma (MTC) patients with increased calcitonin (Ctn) levels but negative CI after thyroidectomy. Fifteen patients with raised Ctn levels and/or CI evidence of recurrence underwent {sup 68}Ga-DOTATATE PET-CT, {sup 111}In-octreotide SPECT-CT and CI. Histopathology, CI and biochemical/clinical/imaging follow-up were used as the reference standard. PET/CT, SPECT/CT and CI were compared in a lesion-based and organ-based analysis. PET/CT evidenced recurrence in 14 of 15 patients. There were 13 true positive (TP), 1 true negative (TN), 1 false positive (FP) and no false negative (FN) cases, resulting in a sensitivity and accuracy of 100% and 93%. SPECT/CT was positive in 6 of 15 cases. There were 6 TP, 2 TN, 7 FN and no FP cases, resulting in a sensitivity of 46% and accuracy of 53%. CI procedures detected tumor lesions in 14 of 15 patients. There were 13 TP, 1TN, 1 FP and no FN cases with a sensitivity of 100% and accuracy of 93%. A significantly higher number of lesions was detected by PET/CT (112 lesions, p = 0.005) and CI (109 lesions, p = 0.005) in comparison to SPECT/CT (16 lesions). There was no significant difference between PET/CT and CI for the total number of detected lesions (p = 0.734). PET/CT detected more lesions than SPECT/CT regardless of the organ. PET/CT detected more bone lesions but missed some neck nodal metastases evidenced by CI. The number of lesions per region demonstrated by PET/CT and CI were similar in the other sites. {sup 68}Ga-DOTATATE PET/CT is superior to {sup 111}In-octreotide SPECT/CT for the detection of recurrent MTC demonstrating a significantly higher number of lesions. {sup 68}Ga-DOTATATE PET/CT showed a superior detection rate compared to CI in demonstrating bone metastases. (orig.)

  13. FIRST DETECTION OF THERMAL RADIOJETS IN A SAMPLE OF PROTO-BROWN DWARF CANDIDATES

    Energy Technology Data Exchange (ETDEWEB)

    Morata, Oscar [Institute of Astronomy and Astrophysics, Academia Sinica, P.O. Box 23-141, Taipei 106, Taiwan (China); Palau, Aina; González, Ricardo F. [Centro de Radioastronomía y Astrofísica, Universidad Nacional Autónoma de México, P.O. Box 3-72, 58090 Morelia, Michoacán, México (Mexico); Gregorio-Monsalvo, Itziar de [Joint ALMA Observatory (JAO), Alonso de Córdova 3107, Vitacura, Santiago (Chile); Ribas, Álvaro [European Space Astronomy Centre (ESA), P.O. Box 78, E-28691 Villanueva de la Cañada, Madrid (Spain); Perger, Manuel [Institut de Ciències de l’Espai (CSIC-IEEC), Campus UAB—Facultat de Ciències, Torre C5—parell 2, E-08193 Bellaterra, Catalunya (Spain); Bouy, Hervé; Barrado, David; Huélamo, Nuria; Morales-Calderón, María [Centro de Astrobiología, INTA-CSIC, Dpto.Astrofísica, ESAC Campus, P.O. Box 78, E-28691 Villanueva de la Cañada, Madrid (Spain); Eiroa, Carlos [Departamento de Física Teórica, Facultad de Ciencias, Universidad Autónoma de Madrid, Cantoblanco, E-28049 Madrid (Spain); Bayo, Amelia, E-mail: omorata@asiaa.sinica.edu.tw [Max Planck Institut für Astronomie, Königstuhl 17, D-69117, Heidelberg (Germany); and others

    2015-07-01

    We observed with the Jansky Very Large Array at 3.6 and 1.3 cm a sample of 11 proto-brown dwarf (BD) candidates in Taurus in a search for thermal radio jets driven by the most embedded BDs. We detected for the first time four thermal radio jets in proto-BD candidates. We compiled data from UKIDSS, 2MASS, Spitzer, WISE, and Herschel to build the spectral energy distribution (SED) of the objects in our sample, which are similar to typical Class I SEDs of young stellar objects (YSOs). The four proto-BD candidates driving thermal radio jets also roughly follow the well-known trend of centimeter luminosity against bolometric luminosity determined for YSOs, assuming they belong to Taurus, although they present some excess of radio emission compared to the known relation for YSOs. Nonetheless, we are able to reproduce the flux densities of the radio jets modeling the centimeter emission of the thermal radio jets using the same type of models applied to YSOs, but with corresponding smaller stellar wind velocities and mass-loss rates, and exploring different possible geometries of the wind or outflow from the star. Moreover, we also find that the modeled mass outflow rates for the bolometric luminosities of our objects agree reasonably well with the trends found between the mass outflow rates and bolometric luminosities of YSOs, which indicates that, despite the “excess” centimeter emission, the intrinsic properties of proto-BDs are consistent with a continuation of those of very low-mass stars to a lower mass range. Overall, our study favors the formation of BDs as a scaled-down version of low-mass stars.

  14. Correlation of needle core biopsy with excision histology in screen-detected B3 lesions: the Merrion Breast Screening Unit experience.

    LENUS (Irish Health Repository)

    Hayes, B D

    2012-02-01

    AIMS: Needle core biopsy (NCB) is a widely-used technique for non-operative evaluation of screen-detected breast lesions. Although most NCBs are B2 (benign) or B5 (malignant), some fall into the B3 category of "uncertain malignant potential". This study aims to categorise the lesions prompting a B3 NCB in the Merrion Breast Screening Unit, and establish the incidence of malignancy on subsequent excision biopsy. METHODS: Patients attending the Merrion Breast Screening Unit in Dublin between 2000 and 2008 who had a B3 NCB were identified. The NCB pathology reports were reviewed and the diagnosis correlated with excision histology; the latter was classified as benign, atypical or malignant. Lesion-specific positive predictive values (PPVs) for malignancy were derived. RESULTS: 141 patients with a B3 NCB were identified. The most frequent lesions on NCB were radial scar (RS; n = 57), atypical intraductal epithelial proliferation (AIDEP; n = 25) and papillary lesion (n = 24). The final diagnosis was malignant in 22 patients (16%), atypical in 40 (28%) and benign in 79 (56%). Two of the patients with a malignant diagnosis had invasive carcinoma. The lesion-specific PPVs were: lobular neoplasia 50%, AIDEP 32%, columnar cell lesion with atypia 12.5%, RS 12.3%, papillary lesion 8.3%, suspected phyllodes tumour 7.7%, and spindle cell lesion 0%. Atypia on RS NCB predicted an atypical or malignant excision diagnosis, but atypia on papillary lesion NCB did not. CONCLUSIONS: One-sixth of B3 NCBs in this series proved to be malignant on excision. The PPV for malignancy varied according to lesion type.

  15. Performance of FLT-PET for pulmonary lesion diagnosis compared with traditional FDG-PET: A meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zixing; Wang, Yuyan [Institute of Basic Medical Sciences, Chinese Academy of Medical Sciences/School of Basic Medicine, Peking Union Medical College, Beijing, 100005 (China); Sui, Xin; Zhang, Wei [Peking Union Medical College Hospital, Chinese Academy of Medical Science, Beijing, 100005 (China); Shi, Ruihong [National Institutes for Food and Drug Control, Beijing, 100000 (China); Zhang, Yingqiang; Dang, Yonghong; Qiao, Zhen [Peking Union Medical College Hospital, Chinese Academy of Medical Science, Beijing, 100005 (China); Zhang, Biao [Institute of Basic Medical Sciences, Chinese Academy of Medical Sciences/School of Basic Medicine, Peking Union Medical College, Beijing, 100005 (China); Song, Wei, E-mail: cjr.songwei@vip.163.com [Peking Union Medical College Hospital, Chinese Academy of Medical Science, Beijing, 100005 (China); Jiang, Jingmei, E-mail: jingmeijiang238@hotmail.com [Institute of Basic Medical Sciences, Chinese Academy of Medical Sciences/School of Basic Medicine, Peking Union Medical College, Beijing, 100005 (China)

    2015-07-15

    Highlights: • FDG PET is more sensitive compared with FLT for detecting small and early staged lung cancers. • FLT can reduce false positives of FDG for inflammation-based lesions such as tuberculosis. • FLT shows comparable accuracies for diagnoses of late stage tumors and larger pulmonary lesions. - Abstract: Purpose: Widely used {sup 18}F 2′-deoxy-2′-fluoro-D-glucose (FDG) positron emission tomography (PET) can be problematic with false positives in cancer imaging. This study aims to investigate the diagnostic accuracy of a candidate PET tracer, {sup 18}F 2′,3′-dideoxy-3′-fluoro-2-thiothymidine (FLT), in diagnosing pulmonary lesions compared with FDG. Materials and methods: After comprehensive search and study selection, a meta-analysis was performed on data from 548 patients pooled from 17 studies for evaluating FLT accuracy, in which data from 351 patients pooled from ten double-tracer studies was used for direct comparison with FDG. Weighted sensitivity and specificity were used as main indicators of test performance. Individual data was extracted and patient subgroup analyses were performed. Results: Overall, direct comparisons showed lower sensitivity (0.80 vs. 0.89) yet higher specificity (0.82 vs. 0.66) for FLT compared with FDG (both p < 0.01). Patient subgroup analysis showed FLT was less sensitive than FDG in detecting lung cancers staged as T1 or T2, and those ≤2.0 cm in diameter (0.81 vs. 0.93, and 0.53 vs. 0.78, respectively, both p < 0.05), but was comparable for cancers staged as T3 or T4, and those >2.0 cm in diameter (0.95 vs. 1.00, 0.96 vs. 0.88, both p > 0.05). For benignities, FLT performed better compared with FDG in ruling out inflammation-based lesions (0.57 vs. 0.32, p < 0.05), and demonstrated greater specificity regardless of lesion sizes. Conclusions: Although FLT cannot replace FDG in detecting small and early lung cancers, it may help to prevent patients with larger or inflammatory lesions from cancer misdiagnosis

  16. "Blind spots" in forensic autopsy: improved detection of retrobulbar hemorrhage and orbital lesions by postmortem computed tomography (PMCT).

    Science.gov (United States)

    Flach, P M; Egli, T C; Bolliger, S A; Berger, N; Ampanozi, G; Thali, M J; Schweitzer, W

    2014-09-01

    The purpose of this study was to correlate the occurrence of retrobulbar hemorrhage (RBH) with mechanism of injury, external signs and autopsy findings to postmortem computed tomography (PMCT). Six-teen subjects presented with RBH and underwent PMCT, external inspection and conventional autopsy. External inspection was evaluated for findings of the bulbs, black eye, raccoon eyes and Battle's sign. Fractures of the viscerocranium, orbital lesions and RBH were evaluated by PMCT. Autopsy and PMCT was evaluated for orbital roof and basilar skull fracture. The leading manner of death was accident with central regulatory failure in cases of RBH (31.25%). Imaging showed a high sensitivity in detection of orbital roof and basilar skull fractures (100%), but was less specific compared to autopsy. Volume of RBH (0.1-2.4ml) correlated positively to the presence of Battle's sign (pautopsy. PMCT was superior in detecting osseous lesions, scrutinizing autopsy as the gold standard. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  17. Indications for diagnostic open biopsy of mammographic screen-detected lesions preoperatively diagnosed as fibroadenomas by needle biopsy and their outcomes

    International Nuclear Information System (INIS)

    Sala, M.A.; Dhillon, R.; Brookes, D.; Lagrange, C.; Metcalf, C.; Wylie, E.

    2015-01-01

    Aim: To identify the clinical, radiological, and histopathological factors that resulted in a diagnostic open biopsy of mammographic screen-detected lesions diagnosed preoperatively as fibroadenomas by needle biopsy. Materials and methods: BreastScreen WA data over 10 year period from 1 January 1999 to 31 December 2008 was reviewed. Results: Among the 760,027 women screened in Western Australia between 1999 and 2008, 31 had a fine-needle aspiration (FNA) or a core biopsy (CB) diagnosing a fibroadenoma and subsequently underwent a diagnostic open biopsy (DOB). Three were preoperatively diagnosed as fibroadenoma by initial FNA but subsequent CB showed that these were not fibroadenomas and, therefore, were excluded from the present series. Of the 28 cases, DOB identified 21 fibroadenomas, two cellular fibroadenomas, two benign phyllodes tumours, one malignant phyllodes tumour, one fibroadenoma containing ductal carcinoma in situ (DCIS), and one case of a 40 mm adenosis tumour with a small 5 mm fibroadenoma. The lesions ranged from 5–100 mm in size with an average size of 28 mm. DOB and CB results were concordant in 25 (89%) of the cases. The primary clinical indications for undergoing DOB included indeterminate histopathological findings of cellular fibroadenomas versus phyllodes tumour (n = 10), enlarging size (n = 4), large size (n = 5), fibroadenomas with atypia (n = 1), discordant radiological and pathological findings (n = 3), patient preference (n = 1), association with a second screen-detected lesion requiring excision (n = 2), and an unknown indication (n = 1). Conclusion: CB diagnosis of fibroadenomas is a safe diagnosis unless it has atypical clinical, radiological, or pathological features. - Highlights: • The aim was to identify factors that lead to excision of benign fibroadenomas. • Screen detected fibroadenomas must be adequately sampled to exclude malignancy. • Large, enlarging, cellular or atypical lesions should undergo

  18. USING STELLAR DENSITIES TO EVALUATE TRANSITING EXOPLANETARY CANDIDATES

    International Nuclear Information System (INIS)

    Tingley, B.; Deeg, H. J.; Bonomo, A. S.

    2011-01-01

    One of the persistent complications in searches for transiting exoplanets is the low percentage of the detected candidates that ultimately prove to be planets, which significantly increases the load on the telescopes used for the follow-up observations to confirm or reject candidates. Several attempts have been made at creating techniques that can pare down candidate lists without the need of additional observations. Some of these techniques involve a detailed analysis of light curve characteristics; others estimate the stellar density or some proxy thereof. In this paper, we extend upon this second approach, exploring the use of independently calculated stellar densities to identify the most promising transiting exoplanet candidates. We use a set of CoRoT candidates and the set of known transiting exoplanets to examine the potential of this approach. In particular, we note the possibilities inherent in the high-precision photometry from space missions, which can detect stellar asteroseismic pulsations from which accurate stellar densities can be extracted without additional observations.

  19. Self-organizing neural networks for automatic detection and classification of contrast-enhancing lesions in dynamic MR-mammography

    International Nuclear Information System (INIS)

    Vomweg, T.W.; Teifke, A.; Kauczor, H.U.; Achenbach, T.; Rieker, O.; Schreiber, W.G.; Heitmann, K.R.; Beier, T.; Thelen, M.

    2005-01-01

    Purpose: Investigation and statistical evaluation of 'Self-Organizing Maps', a special type of neural networks in the field of artificial intelligence, classifying contrast enhancing lesions in dynamic MR-mammography. Material and Methods: 176 investigations with proven histology after core biopsy or operation were randomly divided into two groups. Several Self-Organizing Maps were trained by investigations of the first group to detect and classify contrast enhancing lesions in dynamic MR-mammography. Each single pixel's signal/time curve of all patients within the second group was analyzed by the Self-Organizing Maps. The likelihood of malignancy was visualized by color overlays on the MR-images. At last assessment of contrast-enhancing lesions by each different network was rated visually and evaluated statistically. Results: A well balanced neural network achieved a sensitivity of 90.5% and a specificity of 72.2% in predicting malignancy of 88 enhancing lesions. Detailed analysis of false-positive results revealed that every second fibroadenoma showed a 'typical malignant' signal/time curve without any chance to differentiate between fibroadenomas and malignant tissue regarding contrast enhancement alone; but this special group of lesions was represented by a well-defined area of the Self-Organizing Map. Discussion: Self-Organizing Maps are capable of classifying a dynamic signal/time curve as 'typical benign' or 'typical malignant'. Therefore, they can be used as second opinion. In view of the now known localization of fibroadenomas enhancing like malignant tumors at the Self-Organizing Map, these lesions could be passed to further analysis by additional post-processing elements (e.g., based on T2-weighted series or morphology analysis) in the future. (orig.)

  20. FFA STUDY OF MACULAR LESIONS

    Directory of Open Access Journals (Sweden)

    K. Vinayagamurthy

    2017-08-01

    Full Text Available BACKGROUND Macula is an important portion of retina that occupies the posterior pole of retina. Any disease that affects macula results in significant loss of central vision, form vision and colour vision to an extent. Macular lesions can be hereditary as well as acquired. Macular lesions occur in both younger and older individuals. Anatomically, a macular lesions can vary from a simple lesion like an RPF defect to a vision-threatening lesions like choroidal neovascular membrane. Many screening tests that are sensitive and specific are available to assess the functioning of macula called as ‘macular function test’. But, the greater understanding of the retinal vascular led to the usage of fluorescein angiogram in the detection and screening of macular, retinovascular and optic disc lesions. Through fundus fluorescein angiogram is a thirty-year-old procedure; it is still in vogue in almost all parts of the world. It has its own merits. The aim of the study is to study the role of fluorescein angiography in the evaluation of macular lesions. MATERIALS AND METHODS A hospital-based prospective randomised study was done, which included 50 patients. Detailed patient history was taken and thorough ocular and systemic examination was done. All patients were examined by ophthalmoscopy (direct and indirect and slit-lamp examination with 90D followed by fluorescein angiography. Ophthalmoscopic and fluorescein angiography findings were analysed and categorised. Patients were advised proper ocular and systemic treatment and follow up. RESULTS 50 cases with macular lesions were analysed and categorised into conditions like ARMD, CSR, macular oedema, CME, degenerations and dystrophies and miscellaneous conditions. FFA altered the diagnosis in 8% cases and categorised the cases in all cases. 16% patients developed adverse reactions like allergy, vomiting and nausea. On statistical analysis, FFA proved to be cheap and superior diagnostic tool in confirming

  1. Comparing Melanoma Invasiveness in Dermatologist- versus Patient-Detected Lesions: A Retrospective Chart Review

    Directory of Open Access Journals (Sweden)

    Cindy L. Lamerson

    2012-01-01

    Full Text Available This study examined whether patient-identified melanomas were more advanced than dermatologist-identified tumors at routine clinic visits, and whether a personal or family history of skin cancer was associated with patterns of detection. A retrospective chart review was performed on melanoma patients (N=201 in a private dermatology clinic. Variables included age, gender, pattern of detection (i.e., patient or a board certified dermatologist, personal or family history of skin cancer, skin type, and previous sun exposure, as well as tumor location and severity. Dermatologist-diagnosed melanomas were less invasive (P<0.0005, and more likely present on the chest, back, and legs (P<0.01. Conversely, patient-identified lesions were more likely to occur on the face, neck and scalp, be associated with younger patients, and a family history of melanoma, but not other types of skin cancer (P<0.01. In a post-hoc analysis examining these factors as predictors of tumor invasiveness, only diagnostic source was significant. Specifically, dermatologist-identified tumors were significantly less invasive than patient-identified tumors. Although age, family history, and tumor location played roles in the early detection of melanomas, the most important factor was diagnostic source. Thus, board-certified dermatologists play a key role in the early detection of malignant melanoma.

  2. Lesion size detection in geographic atrophy by polarization-sensitive optical coherence tomography and correlation to conventional imaging techniques.

    Science.gov (United States)

    Schütze, Christopher; Bolz, Matthias; Sayegh, Ramzi; Baumann, Bernhard; Pircher, Michael; Götzinger, Erich; Hitzenberger, Christoph K; Schmidt-Erfurth, Ursula

    2013-01-28

    To investigate the reproducibility of automated lesion size detection in patients with geographic atrophy (GA) using polarization-sensitive spectral-domain optical coherence tomography (PS-OCT) and to compare findings with scanning laser ophthalmoscopy (SLO), fundus autofluorescence (FAF), and intensity-based spectral-domain OCT (SD-OCT). Twenty-nine eyes of 22 patients with GA were examined by PS-OCT, selectively identifying the retinal pigment epithelium (RPE). A novel segmentation algorithm was applied, automatically detecting and quantifying areas of RPE atrophy. The reproducibility of the algorithm was assessed, and lesion sizes were correlated with manually delineated SLO, FAF, and intensity-based SD-OCT images to validate the clinical applicability of PS-OCT in GA evaluation. Mean GA lesion size of all patients was 5.28 mm(2) (SD: 4.92) in PS-OCT. Mean variability of individual repeatability measurements was 0.83 mm(2) (minimum: 0.05; maximum: 3.65). Mean coefficient of variation was 0.07 (min: 0.01; max: 0.19). Mean GA area in SLO (Spectralis OCT) was 5.15 mm(2) (SD: 4.72) and 2.5% smaller than in PS-OCT (P = 0.9, Pearson correlation coefficient = 0.98, P < 0.01). Mean GA area in intensity-based SD-OCT pseudo-SLO images (Cirrus OCT) was 5.14 mm(2) (SD: 4.67) and 2.7% smaller than in PS-OCT (P = 0.9, Pearson correlation coefficient = 0.98, P < 0.01). Mean GA area of all eyes measured 5.41 mm(2) (SD: 4.75) in FAF, deviating by 2.4% from PS-OCT results (P = 0.89, Pearson correlation coefficient = 0.99, P < 0.01). PS-OCT demonstrated high reproducibility of GA lesion size determination. Results correlated well with SLO, FAF, and intensity-based SD-OCT fundus imaging. PS-OCT may therefore be a valuable and specific imaging modality for automated GA lesion size determination in scientific studies and clinical practice.

  3. Effect of dependency versus nondependency on lung lesion visualization

    International Nuclear Information System (INIS)

    Pechman, R.D. Jr.

    1987-01-01

    Paraffin blocks and mineral oil were used as a model to determine the effect of dependency versus nondependency on radiographic visualization of lung lesions in lateral thoracic radiographs. It was concluded that the increased opacity of the material surrounding the lesion, not contact between the heart and the lesion, was responsible for the inability to detect lung disease in the dependent lung. The results were tested in dogs with pneumonia in the right middle lung lobe. When the dog was in right lateral recumbency, the dependent right lung was increased in opacity and decreased in volume and the pulmonary lesion was difficult to detect. When the dog was in left lateral recumbency, the non dependent right lung was increased in volume and decreased in opacity and the pulmonary disease was clearly visible. A single recumbent lateral radiograph must not be used to assess a dog with suspected lung disease because lesions in the dependent lung lobes may not be detected

  4. TU-G-204-02: Automatic Sclerotic Bone Metastases Detection in the Pelvic Region From Dual Energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Fehr, D; Schmidtlein, C; Hwang, S; Deasy, J; Veeraraghavan, H [Memorial Sloan Kettering Cancer Center, New York, NY (United States)

    2015-06-15

    Purpose: To automatically detect sclerotic bone metastases in the pelvic region using dual energy computed tomography (DECT). Methods: We developed a two stage algorithm to automatically detect sclerotic bone metastases in the pelvis from DECT for patients with multiple bone metastatic lesions and with hip implants. The first stage consists of extracting the bone and marrow regions by using a support vector machine (SVM) classifier. We employed a novel representation of the DECT images using multi-material decomposition, which represents each voxel as a mixture of different physical materials (e.g. bone+water+fat). Following the extraction of bone and marrow, in the second stage, a bi -histogram equalization method was employed to enhance the contrast to reveal the bone metastases. Next, meanshift segmentation was performed to separate the voxels by their intensity levels. Finally, shape-based filtering was performed to extract the possible locations of the metastatic lesions using multiple shape criteria. We used the following shape parameters: area, eccentricity, major and minor axis, perimeter and skeleton. Results: A radiologist with several years of experience with DECT manually labeled 64 regions consisting of metastatic lesions from 10 different patients. However, the patients had many more metastasic lesions throughout the pelvis. Our method correctly identified 46 of the marked 64 regions (72%). In addition, our method also identified several other lesions, which can then be validated by the radiologist. The missed lesions were typically very large elongated regions consisting of several islands of very small (<4mm) lesions. Conclusion: We developed an algorithm to automatically detect sclerotic lesions in the pelvic region from DECT. Preliminary assessment shows that our algorithm generated lesions agreeing with the radiologist generated candidate regions. Furthermore, our method reveals additional lesions that can be inspected by the radiologist, thereby

  5. Magnetic resonance imaging of spinal cord lesions in 22 multiple sclerosis patients

    International Nuclear Information System (INIS)

    Kato, Hiroshi; Funakawa, Itaru; Hara, Kenji; Yasuda, Takeshi; Terao, Akira

    1994-01-01

    We reviewed MRI findings in 22 patients (37 cases) with clinically diagnosed multiple sclerosis (MS) with spinal cord lesions. The spinal cord lesions were detected in 17 (46%) of these 37 cases on MRI. The cervical cord lesions were more detectable than other spinal cord lesions. At the thoracic level, the upper lesions were more detectable than the lower ones. In this study, no correlation was found between the disease duration, the rate of functional disturbance and the detectable rate of spinal cord lesions. The characteristic findings of the lesions were swelling and the enhancement effect of Gd-DTPA in the patient group with a disease duration of less than three years, and atrophic change in the patient group with a disease duration of greater than seven years. The period of the enhancement effect of Gd-DTPA varied in each case, and it may reflect the clinical course. Syrinx-like lesions were found in four cases. In one of them, atrophic change was found in the same region six months after the follow up study. Although the precise reason for the syrinx-like lesion was unclear, a relationship between syrinx-like lesion and atrophy of the spinal cord was suggested. The MRI findings of the spinal cord lesions in MS varied in each case and in each stage of the disease. (author)

  6. A study to determine the association between tobacco smoking habit and oral candidal infection in median rhomboid glossitis by cytologic and histopathologic methods

    Directory of Open Access Journals (Sweden)

    Anitha Bojan

    2012-01-01

    Full Text Available Objectives: To determine the association, if any, between tobacco smoking and candidal infection in median rhomboid glossitis (MRG and to histopathologically evaluate the presence of dysplastic changes in it. Study design: Hospital-based study consisting of 100 subjects who satisfied the clinical criteria of MRG- Smears and swabs were collected to ascertain the presence of Candida and sub-typing was done utilizing the CHROMagar technique. Biopsy and histopathological examination was done to determine the presence or absence of dysplasia of the lesional tissue. Results: All the subjects were male and had the habit of smoking- Smears and swabs taken from glossal lesion of 60 subjects′ showed 100% candidal positivity. Tissue section from 31 subjects showed histological picture consistent with MRG and 23 (74% showed dysplastic changes. Conclusion: MRG is a Candida-associated lesion and the tobacco-smoking habit in our cohort may play an important role in increasing the candidal colonization. As some of our cases exhibited mild epithelial dysplasia, both candidal colonization and smoking habits may have contributed to the dysplastic changes.

  7. Visible and occult microscopic lesions of endometriosis

    Directory of Open Access Journals (Sweden)

    Khaleque Newaz Khan

    2014-11-01

    Full Text Available Endometriosis is a multifactorial disease mostly affecting women of reproductive age and is associated with chronic pelvic pain and infertility. Even after 300 years, most of the literature claims that pathogenesis and/or pathophysiology of endometriosis is still elusive. Recurrence of pain and lesion continues to occur after effective medical or surgical therapies. Once generated within the pelvis due to retrograde entry of menstrual debris, peritoneal endometriotic lesions time-dependently change their color appearance resulting from certain biochemical change within lesions. A variable pattern of endometriotic lesions within the pelvis can be detected by laparoscopy as visible peritoneal endometriosis. It is generally believed that besides ovarian steroid hormones, the growth of endometriosis can be regulated by the innate immune system in the pelvic microenvironment by their interaction with endometrial cells and immune cells. Even with the careful eyes of an expert surgeon, we may sometimes miss detecting peritoneal lesion within the peritoneal cavity or deep into the peritoneum. In such a case, random collection of normal peritoneum may carry the possibility to identify some hidden endometriotic lesions by microscopy and these lesions can be named as occult (invisible microscopic endometriosis (OME. Here, we discuss the color appearance of peritoneal lesions and activity of these lesions by analysis of a panel of activity markers. Finally we discuss our recent findings on OME, their biological and clinical significance, and try to make a possible link in the origin between visible endometriosis and OME.

  8. Cerebral ischemic lesions detected with diffusion-weighted magnetic resonance imaging after carotid artery stenting: Comparison of several anti-embolic protection devices.

    Science.gov (United States)

    Taha, Mahmoud M; Maeda, Masayuki; Sakaida, Hiroshi; Kawaguchi, Kenji; Toma, Naoki; Yamamoto, Akitaka; Hirose, Tomofumi; Miura, Youichi; Fujimoto, Masashi; Matsushima, Satoshi; Taki, Waro

    2009-09-01

    Distal embolism is an important periprocedural technical complication with carotid angioplasty and carotid artery stenting (CAS). We evaluated the safety and efficacy of protection devices used during CAS by detecting new cerebral ischemic lesions using diffusion-weighted magnetic resonance imaging in 95 patients who underwent 98 CAS procedures: 34 using single PercuSurge GuardWire, 31 using double balloon protection, 15 using proximal flow reverse protection devices, 14 using Naviballoon, and 4 using filter anti-embolic devices. Diffusion-weighted imaging was performed preoperatively and postoperatively to evaluate the presence of any new embolic cerebral lesions. Postoperative diffusion-weighted imaging revealed 117 new ischemic lesions. Three patients had new ischemic stroke, two minor and one major, all ipsilateral to the treated carotid artery. The remaining patients had clinically silent ischemia. The incidence of new embolic lesions was lower using the proximal flow reverse protection device than with the double balloon protection (33% vs. 48.4%), but the volume of ipsilateral new ischemic lesions per patient was 136.6 mm(3) vs. 86.9 mm(3), respectively. Neuroprotection with Naviballoon yielded ipsilateral lesions of large volume (86.6 mm(3)) and higher number (5.7 lesions per patient) than using the filter anti-embolic device (34.8 mm(3) and 1 lesion per patient). New cerebral ischemic lesions after neuroprotected CAS are usually silent. The lower incidence of distal ischemia using proximal flow reverse and double balloon protection devices is limited by the larger volume and higher number of ischemic lesions.

  9. Cerebral ischemic lesions detected with diffusion-weighted magnetic resonance imaging after carotid artery stenting. Comparison of several anti-embolic protection devices

    International Nuclear Information System (INIS)

    Taha, M.M.; Maeda, Masayuki; Sakaida, Hiroshi

    2009-01-01

    Distal embolism is an important periprocedural technical complication with carotid angioplasty and carotid artery stenting (CAS). We evaluated the safety and efficacy of protection devices used during CAS by detecting new cerebral ischemic lesions using diffusion-weighted magnetic resonance imaging in 95 patients who underwent 98 CAS procedures: 34 using single PercuSurge GuardWire, 31 using double balloon protection, 15 using proximal flow reverse protection devices, 14 using Naviballoon, and 4 using filter anti-embolic devices. Diffusion-weighted imaging was performed preoperatively and postoperatively to evaluate the presence of any new embolic cerebral lesions. Postoperative diffusion-weighted imaging revealed 117 new ischemic lesions. Three patients had new ischemic stroke, two minor and one major, all ipsilateral to the treated carotid artery. The remaining patients had clinically silent ischemia. The incidence of new embolic lesions was lower using the proximal flow reverse protection device than with the double balloon protection (33% vs. 48.4%), but the volume of ipsilateral new ischemic lesions per patient was 136.6 mm 3 vs. 86.9 mm 3 , respectively. Neuroprotection with Naviballoon yielded ipsilateral lesions of large volume (86.6 mm 3 ) and higher number (5.7 lesions per patient) than using the filter anti-embolic device (34.8 mm 3 and 1 lesion per patient). New cerebral ischemic lesions after neuroprotected CAS are usually silent. The lower incidence of distal ischemia using proximal flow reverse and double balloon protection devices is limited by the larger volume and higher number of ischemic lesions. (author)

  10. Functional validation of candidate genes detected by genomic feature models

    DEFF Research Database (Denmark)

    Rohde, Palle Duun; Østergaard, Solveig; Kristensen, Torsten Nygaard

    2018-01-01

    Understanding the genetic underpinnings of complex traits requires knowledge of the genetic variants that contribute to phenotypic variability. Reliable statistical approaches are needed to obtain such knowledge. In genome-wide association studies, variants are tested for association with trait...... then functionally assessed whether the identified candidate genes affected locomotor activity by reducing gene expression using RNA interference. In five of the seven candidate genes tested, reduced gene expression altered the phenotype. The ranking of genes within the predictive GO term was highly correlated...

  11. Clinical application of three dimensional ultrafast MR imaging to intracerebral traumatic lesions

    International Nuclear Information System (INIS)

    Enomoto, Kyoko; Amanuma, Makoto; Hasegawa, Makoto; Watabe, Tsuneya; Heshiki, Atsuko

    1994-01-01

    We applied a T1-weighted three-dimensional (3D) magnetization-prepared rapid gradient-echo sequence (MPRAGE) for the detection of intracerebral lesions associated with closed head injuries. Thirty-four patients underwent brain MR imaging on a 1.5 Tesla superconducting MR unit. We applied an MPRAGE sequence, together with spin echo (SE) and gradient echo (GRE) sequences, and evaluated the detectability of lesions with each sequence. A total of 100 intracerebral traumatic lesions (33 cortical contusion, 56 diffuse axonal injury, 11 subcortical gray matter injury) were found. Ninety-seven percent of all lesions were detected on MPRAGE images, and 67% on SE and GRE images. The detectability of lesions in each category was 91%, 98%, and 100% on MPRAGE images, and 88%, 54%, and 73% on either SE or GRE images. 3D MPRAGE is a promising method to detect intracerebral traumatic lesions, particularly those associated with diffuse axonal injury, because of its high quality of contrast and spatial resolution and the capability of image reconstruction in any plane. (author)

  12. Roentgenologic diagnostics of capsular ligament lesions

    Energy Technology Data Exchange (ETDEWEB)

    Wirth, C.J.; Jaeger, M.

    1981-10-01

    The X-ray diagnostic is of obvious importance and relevance in the detection of acute or old capsular ligament lesions of the limb joint. On the one hand it serves as the plain radiograph (roentgenogram without contrast medium) for the assessment of osseous secondary lesions, for the documentation of luxationary positions of the joint partners, and in old capsular ligament lesions for the detection of an already existing arthrosis. On the other hand the X-ray images are of main importance, which are made from the hand-held limb in order to permit a comparison of the two sides, and which beyond the clinical detection of a joint instability indicate the extent and the direction of this instability and which also document it, and which allow in adolescents to recognize a separation of the epiphysis as an alternative to the capsular ligament rupture. Only in particular cases arthrography can provide some additional information, so for example in the case of an isolated syndesmosis rupture, ruptures of the rosette of the rotator muscle or of a damaged triangular disk in the hand. Angiography is only required in cases of traumatic luxations of the knee in order to exclude an intimal lesion of the popliteal artery.

  13. Flow cytometric techniques for detection of candidate cancer stem cell subpopulations in canine tumour models.

    Science.gov (United States)

    Blacking, T M; Waterfall, M; Samuel, K; Argyle, D J

    2012-12-01

    The cancer stem cell (CSC) hypothesis proposes that tumour growth is maintained by a distinct subpopulation of 'CSC'. This study applied flow cytometric methods, reported to detect CSC in both primary and cultured cancer cells of other species, to identify candidate canine subpopulations. Cell lines representing diverse canine malignancies, and cells derived from spontaneous canine tumours, were evaluated for expression of stem cell-associated surface markers (CD34, CD44, CD117 and CD133) and functional properties [Hoecsht 33342 efflux, aldehyde dehydrogenase (ALDH) activity]. No discrete marker-defined subsets were identified within established cell lines; cells derived directly from spontaneous tumours demonstrated more heterogeneity, although this diminished upon in vitro culture. Functional assays produced variable results, suggesting context-dependency. Flow cytometric methods may be adopted to identify putative canine CSC. Whilst cell lines are valuable in assay development, primary cells may provide a more rewarding model for studying tumour heterogeneity in the context of CSC. However, it will be essential to fully characterize any candidate subpopulations to ensure that they meet CSC criteria. © 2011 Blackwell Publishing Ltd.

  14. Detection of intrathoracic infectious lesions using 111In-diethylenetriamine pentaacetic bicyclic anhydride-IgG (111In-DTPA-IgG) scintigraphy

    International Nuclear Information System (INIS)

    Ota, Tomohiro; Goto, Hajime; Wada, Hiroo; Yuasa, Kazumi; Iguchi, Mari; Okamura, Tatsuru; Ieki, Ryuji; Suzuki, Kenzo

    1998-01-01

    The utility of 111 In-DTPA-IgG imaging for the detection of intrathoracic lesions was evaluated in 10 patients with the suspicion of inflammatory or infectious diseases. They were intravenously administered 40 or 80 MBq of 111 In-DTPA-IgG, and scanned after 24 or 48 hours. Of these, 8 cases, consisted of 4 cases with pneumonia and 2 cases with lung abscess and one case of pulmonary tuberculosis and one of a tuberculous pleuritis, showed true positive results. Others were one false negative case of pneumonia and one true negative case of lung cancer. Overall sensitivity and specificity were 88.9% and 100%, respectively. There were no cases which showed side effects or abnormal laboratory findings caused by the radiopharmaceuticals administered. Thus, 111 In-DTPA-IgG imaging is a useful tool for the detection of intrathoracic infectious lesions. (author)

  15. An improved strategy for skin lesion detection and classification using uniform segmentation and feature selection based approach.

    Science.gov (United States)

    Nasir, Muhammad; Attique Khan, Muhammad; Sharif, Muhammad; Lali, Ikram Ullah; Saba, Tanzila; Iqbal, Tassawar

    2018-02-21

    Melanoma is the deadliest type of skin cancer with highest mortality rate. However, the annihilation in early stage implies a high survival rate therefore, it demands early diagnosis. The accustomed diagnosis methods are costly and cumbersome due to the involvement of experienced experts as well as the requirements for highly equipped environment. The recent advancements in computerized solutions for these diagnoses are highly promising with improved accuracy and efficiency. In this article, we proposed a method for the classification of melanoma and benign skin lesions. Our approach integrates preprocessing, lesion segmentation, features extraction, features selection, and classification. Preprocessing is executed in the context of hair removal by DullRazor, whereas lesion texture and color information are utilized to enhance the lesion contrast. In lesion segmentation, a hybrid technique has been implemented and results are fused using additive law of probability. Serial based method is applied subsequently that extracts and fuses the traits such as color, texture, and HOG (shape). The fused features are selected afterwards by implementing a novel Boltzman Entropy method. Finally, the selected features are classified by Support Vector Machine. The proposed method is evaluated on publically available data set PH2. Our approach has provided promising results of sensitivity 97.7%, specificity 96.7%, accuracy 97.5%, and F-score 97.5%, which are significantly better than the results of existing methods available on the same data set. The proposed method detects and classifies melanoma significantly good as compared to existing methods. © 2018 Wiley Periodicals, Inc.

  16. Diagnostic performance of reduced-dose CT with a hybrid iterative reconstruction algorithm for the detection of hypervascular liver lesions: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Nakamoto, Atsushi; Tanaka, Yoshikazu; Juri, Hiroshi; Nakai, Go; Narumi, Yoshifumi [Osaka Medical College, Department of Radiology, Takatsuki, Osaka (Japan); Yoshikawa, Shushi [Osaka Medical College Hospital, Central Radiology Department, Takatsuki, Osaka (Japan)

    2017-07-15

    To investigate the diagnostic performance of reduced-dose CT with a hybrid iterative reconstruction (IR) algorithm for the detection of hypervascular liver lesions. Thirty liver phantoms with or without simulated hypervascular lesions were scanned with a 320-slice CT scanner with control-dose (40 mAs) and reduced-dose (30 and 20 mAs) settings. Control-dose images were reconstructed with filtered back projection (FBP), and reduced-dose images were reconstructed with FBP and a hybrid IR algorithm. Objective image noise and the lesion to liver contrast-to-noise ratio (CNR) were evaluated quantitatively. Images were interpreted independently by 2 blinded radiologists, and jackknife alternative free-response receiver-operating characteristic (JAFROC) analysis was performed. Hybrid IR images with reduced-dose settings (both 30 and 20 mAs) yielded significantly lower objective image noise and higher CNR than control-dose FBP images (P <.05). However, hybrid IR images with reduced-dose settings had lower JAFROC1 figure of merit than control-dose FBP images, although only the difference between 20 mAs images and control-dose FBP images was significant for both readers (P <.01). An aggressive reduction of the radiation dose would impair the detectability of hypervascular liver lesions, although objective image noise and CNR would be preserved by a hybrid IR algorithm. (orig.)

  17. Diagnostic imaging to select the candidates to orthotopic transplantation: Experience in a general hospital

    International Nuclear Information System (INIS)

    Pozzato, Carlo; Baldini, Umberto; Gattoni, Filippo; Raiteri, Riccardo; Lazzerini, Francesco; Uslenghi, Carlo Matteo; Mevoli, Alessandra

    1997-01-01

    The authors report the experience of our general hospital in selecting the patients for orthotopic liver transplantation (OLT). The accuracy of duplex Doppler and color flow Doppler for portal and/or mesenteric vein thrombosis was evaluated by correlation with resected livers, computerized tomography and angiographic findings. Pathologic examinations diagnosed HCC in 5/20 transplant recipients: 2 lesions were found in 2 resected specimens (total hepatectomy) and 1 lesion was found in 3 cases. The sensitivity of US, plain and dynamic computerized tomography in identifying HCC patients was 20%; US and computerized tomography specificity rates were 100% and 87%, respectively. CTAP sensitivity was 75% and the sensitivity of Lipiodol computerized tomography and angiography was 100%. Therefore, in our series, US was poorly sensitivity in the detection of liver cancers, which may depend on the small number of patients, lesion size and the radiologists ignoring clinical and laboratory data on purpose. Nevertheless, the patients with a single HCC not exceeding 5 cm in diameter or with no more than 3 tumors, none of them exceeding 3 cm in diameter, are generally considered eligible for transplantation: therefore, our patients chosen for OLT on the basis of US and computerized tomography findings were actually eligible for transplantation in spite of US and computerized tomography false negative results. In conclusion, considering also the long stand-by list for OLT, the first selection of transplant candidates could be performed with US and color flow Doppler, plain and dynamic computerized tomography. The patients who are not ruled out as candidates for OLT on the basis of the findings of these imaging techniques and of clinical and laboratory findings are submitted to no further examination and referred to the transplantation unit. Otherwise, if conventional and color flow Doppler US and conventional computerized tomography are not enough to exclude a patient from OLT, the

  18. Candida spp. in oral cancer and oral precancerous lesions.

    Science.gov (United States)

    Gall, Francesca; Colella, Giuseppe; Di Onofrio, Valeria; Rossiello, Raffaele; Angelillo, Italo Francesco; Liguori, Giorgio

    2013-07-01

    To assess the presence of Candida spp. in lesions of the oral cavity in a sample of patients with precancer or cancer of the mouth and evaluate the limitations and advantages of microbiological and histological methods, 103 subjects with precancerous or cancerous lesions and not treated were observed between 2007 and 2009. The presence of Candida in the lesions was analyzed by microbiological and histological methods. Cohen's k statistic was used to assess the agreement between culture method and staining techniques. Forty-eight (47%) patients had cancer and 55 (53%) patients had precancerous lesions. Candida spp. were isolated from 31 (30%) patients with cancerous lesions and 33 (32%) with precancerous lesions. C. albicans was the most frequent species isolated in the lesions. The k value showed a fair overall agreement for comparisons between culture method and PAS (0.2825) or GMS (0.3112). This study supports the frequent presence of Candida spp. in cancer and precancerous lesions of the oral cavity. Both microbiological investigations and histological techniques were reliable for detection of Candida spp. It would be desirable for the two techniques to be considered complementary in the detection of yeast infections in these types of lesions.

  19. Prevalence of oral lesions in pan vendor

    Directory of Open Access Journals (Sweden)

    Prakash Gadodia

    2011-01-01

    Full Text Available Background: Being a portal of entry to various smoking and smokeless tobacco products, oral cavity is prone to deleterious effects. Present study consist of epidemiological survey to elucidate oral lesions in pan vendors. Aims and objectives: To detect oral lesions in pan vendors and compare it with controls. To detect habit pattern and prevalence of OSMF and other lesions in pan vendors as compared to controls- To identify, recognize and evaluate the possible etiology for OSMF, encompassing various chewing and smoking habits. Materials and methods: Study population consist of 170 pan vendors with age ranging from 15 to 55 years and equal number of sex matched controls selected randomly. Results: Prevalence of oral lesions in pan vendors is statistically significantly higher as compared to controls. The habit of arecanut chewing in various forms was present in all cases. The habit of smoking and smokeless tobacco products was present in all cases. Conclusion: Pan vendors are at higher risk for oral lesions than controls. There is increase in relative risk with increase in duration and frequency of habit.

  20. Feasibility Study of a Generalized Framework for Developing Computer-Aided Detection Systems-a New Paradigm.

    Science.gov (United States)

    Nemoto, Mitsutaka; Hayashi, Naoto; Hanaoka, Shouhei; Nomura, Yukihiro; Miki, Soichiro; Yoshikawa, Takeharu

    2017-10-01

    We propose a generalized framework for developing computer-aided detection (CADe) systems whose characteristics depend only on those of the training dataset. The purpose of this study is to show the feasibility of the framework. Two different CADe systems were experimentally developed by a prototype of the framework, but with different training datasets. The CADe systems include four components; preprocessing, candidate area extraction, candidate detection, and candidate classification. Four pretrained algorithms with dedicated optimization/setting methods corresponding to the respective components were prepared in advance. The pretrained algorithms were sequentially trained in the order of processing of the components. In this study, two different datasets, brain MRA with cerebral aneurysms and chest CT with lung nodules, were collected to develop two different types of CADe systems in the framework. The performances of the developed CADe systems were evaluated by threefold cross-validation. The CADe systems for detecting cerebral aneurysms in brain MRAs and for detecting lung nodules in chest CTs were successfully developed using the respective datasets. The framework was shown to be feasible by the successful development of the two different types of CADe systems. The feasibility of this framework shows promise for a new paradigm in the development of CADe systems: development of CADe systems without any lesion specific algorithm designing.

  1. Extirpation of a cranial lesion radio guided by scintigraphy and intraoperative detection

    International Nuclear Information System (INIS)

    Concha Julio, Enrique; Basuri, Luciano; Otayza, Felipe; Neubauer, Sonia; Mena, Ismael; Arteaga, Maria Paz

    2005-01-01

    A skull lesion may be difficult to localize, specially a small one that is not evident on the external surface. In this paper, we describe the localization and extirpation aided by intraoperative radio guidance of a 2 cm lesion compromising the internal aspect of the posterior temporal bone. The radiological expression of this lesion was poor, both on the plain radiograph's and on the computed tomography, making the intraoperative radiology and the navigation aided by computed tomography useless. The lesion was extirpated in block and the skull repaired. The biopsy confirmed a Paget's disease. There were not surgical complications (au)

  2. Optical observations of the nearby galaxy IC342 with narrow band [SII] and hα filters. II - detection of 16 optically-identified supernova remnant candidates

    Directory of Open Access Journals (Sweden)

    Vučetić M.M.

    2015-01-01

    Full Text Available We present the detection of 16 optical supernova remnant (SNR candidates in the nearby spiral galaxy IC342. The candidates were detected by applying the [Sii]/Hα ratio criterion on observations made with the 2 m RCC telescope at Rozhen National Astronomical Observatory in Bulgaria. In this paper, we report the coordinates, diameters, Hα and [S ii] fluxes for 16 SNRs detected in two fields of view in the IC342 galaxy. Also, we estimate the contamination of total Hα flux from SNRs in the observed portion of IC342 to be 1.4%. This would represent the fractional error when the star formation rate (SFR for this galaxy is derived from the total galaxy’s Hα emission.

  3. Real-time PCR detection of Brucella spp. DNA in lesions and viscera of bovine carcasses.

    Science.gov (United States)

    Sola, Marília Cristina; da Veiga Jardim, Eurione A G; de Freitas, Marcius Ribeiro; de Mesquita, Albenones José

    2014-09-01

    This study reports a real-time PCR assay for the detection of Brucella spp. associated with the FTA® Elute method in lesions observed during sanitary inspections in beef slaughter. Of the total 276 samples, 78 (28.3%) tested positive and 198 (71.7%) negative for Brucella spp. The real-time PCR technique associated with the FTA® Elute method proved to be an important tool for the diagnosis, judgment about and disposal of carcasses and viscera of slaughtered animals. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Cone-beam computed tomography versus digital periapical radiography in the detection of artificially created periapical lesions: A pilot study of the diagnostic accuracy of endodontists using both techniques

    Energy Technology Data Exchange (ETDEWEB)

    Campello, Abdrea Fagundes; Goncalves, Lucio Souza; Marques, Fabio vidal [Faculty of Dentistry, Estacio de Sa University, Rio de Janeiro (Brazil); Guedes, Fabio Ribeiro [Faculty of Dentistry, Federal University of Rio de Janeiro, Rio de Janeiro (Brazil)

    2017-03-15

    The aim of this study was to compare the diagnostic accuracy of previously trained endodontists in the detection of artificially created periapical lesions using cone-beam computed tomography (CBCT) and digital periapical radiography (DPR). An ex vivo model using dry skulls was used, in which simulated apical lesions were created and then progressively enlarged using no.1/2, no.2, no.4, and no.6 round burs. A total of 11 teeth were included in the study, and 110 images were obtained with CBCT and with an intraoral digital periapical radiographic sensor (Instrumentarium dental, Tuusula, Finland) initially and after each bur was used. Specificity and sensitivity were calculated. All images were evaluated by 10 previously trained, certified endodontists. Agreement was calculated using the kappa coefficient. The accuracy of each method in detecting apical lesions was calculated using the chi-square test. The kappa coefficient between examiners showed low agreement (range, 0.17-0.64). No statistical difference was found between CBCT and DPR in teeth without apical lesions (P=.15). The accuracy for CBCT was significantly higher than for DPR in all corresponding simulated lesions (P<.001). The correct diagnostic rate for CBCT ranged between 56.9% and 73.6%. The greatest difference between CBCT and DPR was seen in the maxillary teeth (CBCT, 71.4%; DPR, 28.6%; P<.01) and multi-rooted teeth (CBCT, 83.3%; DPR, 33.3%; P<.01). CBCT allowed higher accuracy than DPR in detecting simulated lesions for all simulated lesions tested. Endodontists need to be properly trained in interpreting CBCT scans to achieve higher diagnostic accuracy.

  5. Development and psychometric testing of the 'Motivation and Self-Efficacy in Early Detection of Skin Lesions' index.

    Science.gov (United States)

    Dyson, Judith; Cowdell, Fiona

    2014-12-01

    To develop and psychometrically test the Motivation and Self-Efficacy in Early Detection of Skin Lesions Index. Skin cancer is the most frequently diagnosed cancer worldwide. The primary strategy used to prevent skin cancer is promotion of sun avoidance and the use of sun protection. However, despite costly and extensive campaigns, cases of skin cancer continue to increase. If found and treated early, skin cancer is curable. Early detection is, therefore, very important. The study was conducted in 2013. Instrument Development. A literature review and a survey identified barriers (factors that hinder) and levers (factors that help) to skin self-examination. These were categorized according to a the Theoretical Domains Framework and this formed the basis of an instrument, which was tested for validity and reliability using confirmatory factor analysis and Cronbach's alpha respectively. A five-factor 20-item instrument was used that tested well for reliability and construct validity. Test-retest reliability was good for all items and domains. The five factors were: (i) Outcome expectancies; (ii) Intention; (iii) Self-efficacy; (iv) Social influences; (v) Memory. The Motivation and Self-Efficacy in Early Detection of Skin Lesions Index provides a reliable and valid method of assessing barriers and levers to skin self-examination. The next step is to design a theory-based intervention that can be tailored according to individual determinants to behaviour change identified by this instrument. © 2014 John Wiley & Sons Ltd.

  6. Magnetic resonance imaging at 3.0 tesla detects more lesions in acute optic neuritis than at 1.5 tesla

    DEFF Research Database (Denmark)

    Nielsen, Kirsten; Rostrup, Egill; Frederiksen, Jette L

    2006-01-01

    OBJECTIVE:: We sought to assess whether magnetic resonance imaging (MRI) at 3.0 T detects more brain lesions in acute optic neuritis (ON) than MRI at 1.5 T. MATERIALS AND METHODS:: Twenty-eight patients with acute ON were scanned at both field-strengths using fast-fluid-attenuated inversion recov...

  7. Brain lesions in congenital nystagmus as detected by computed tomography

    International Nuclear Information System (INIS)

    Lo, Chin-Ying

    1982-01-01

    Computed tomography (CT) was performed in a series of 60 cases with congenital nystagmus. The type of nystagmus was pendular in 20 and jerky in 40 cases. The age ranged from 3 months to 13 years. Abnormal CT findings of the central nervous system were detected in 31 cases (52%). There were 5 major CT findings: midline anomalies, cortical atrophy, ventricular dilatation, brain stem atrophy and low density area. The midline anomalies involved cavum septi pellucidi, cavum Vergae, cavum veli interpositi and partial agenesis of corpus callosum. The abnormal CT findings were more prominent in pendular type than in jerky type. The incidence of congenital nystagmus and positive CT findings were the same in the first and the second birth. There was a history of abnormalities during the prenatal or perinatal period in 28 out of the 60 cases (47%). This feature seemed to play a significant role in the occurrence of congenital nystagmus. The observed organic lesions in the central nervous system by CT would contribute to the elucidation of pathomechanism of congenital nystagmus. (author)

  8. Conspicuity of diffuse axonal injury lesions on diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Kinoshita, Toshibumi; Moritani, Toshio; Hiwatashi, Akio; Wang, Henry Z.; Shrier, David A.; Numaguchi, Yuji; Westesson, Per-Lennart A.

    2005-01-01

    Objective: (1) To detect diffuse axonal injury (DAI) lesions by diffusion-weighted imaging (DWI), as compared with fluid-attenuated inversion recovery (FLAIR) imaging and (2) to evaluate hemorrhagic DAI lesions by b 0 images obtained from DWI, as compared with gradient-echo (GRE) imaging. Methods: We reviewed MR images of 36 patients with a diagnosis of DAI. MR imaging was performed 20 h to 14 days (mean, 3.7 days) after traumatic brain injury. We evaluated: (1) conspicuity of lesions on DWI and FLAIR and (2) conspicuity of hemorrhage in DAI lesions on b 0 images and GRE imaging. Results: DWI clearly depicted high-signal DAI lesions. The sensitivity of DWI to lesional conspicuity in DAI lesions was almost equal to that of FLAIR. The sensitivity of b 0 images to identification of hemorrhagic DAI lesions was inferior to that of GRE. Conclusion: DWI is as useful as FLAIR in detecting DAI lesions. GRE imaging is still the superior tool for the evaluation of hemorrhagic DAI

  9. Clinical studies on the visualization of gastric lesions using virtual CT endoscopy

    International Nuclear Information System (INIS)

    Kim, Hideki; Takashima, Sumio; Kaminou, Toshio; Hayashi, Seisyo; Nishida, Norifumi; Matsuoka, Toshiyuki; Nakamura, Kenji; Yamada, Ryusaku

    2001-01-01

    We evaluated the clinical usefulness of virtual CT gastro endoscopy (VCTGE). The subjects were 124 patients with endoscopically identified gastric lesions. VCTGE images were obtained using a GE-Navigator. We evaluated VCTGE in the visualization of gastric lesions for their presence and morphology. The detection rate of all gastric lesions by VCTGE was 76% (94 of 124 patients). The smallest detectable early gastric cancer was II c measuring 10 x 8 mm. The detection rates of each gastric lesion by VCTGE were 73% in early gastric cancer, and 90% in advanced gastric cancer. VCTGE imaging in the advanced gastric cancer was good in 12 (30%), fair in 25 (60%) and poor in 4 (10%). VCTGE imaging in early gastric cancer was good in 20 (46%), fair in 12 (27%) and poor in 12 (27%). The significance P level was 0.005 between the evaluation of the imaging of advanced and early gastric cancer. VCTGE visualized the characteristics of diverse gastric lesions and was considered useful for the detection and the diagnosis of these lesions. (author)

  10. Comparison of the prevalence of human papilloma virus infection in histopathologically confirmed premalignant oral lesions and healthy oral mucosa by brush smear detection.

    Science.gov (United States)

    Dalla Torre, Daniel; Burtscher, Doris; Edlinger, Michael; Sölder, Elisabeth; Widschwendter, Andreas; Rasse, Michael; Puelacher, Wolfgang

    2015-03-01

    The role of human papilloma virus (HPV) infections in oral carcinogenesis is an important topic of research in maxillofacial oncology. Nevertheless, the association between such infections in the oral cavity and the development of oral precancerous lesions remains unclear. The aim of this study was to evaluate the association between oral HPV infections and oral leukoplakia or erythroplakia. The case control study included 118 patients with manifest oral leukoplakia or erythroplakia, who underwent surgical biopsy, including a histopathologic grading of the lesion, and 100 control patients without any oral lesions. HPV detection was achieved with a noninvasive brush smear method (Digene Cervical Sampler, Hybrid Capture II-Test). Logistic regression analysis was performed to assess the associations. A significant association was found between high-risk oral HPV infection and the presence of oral premalignant lesions (P = .001). Among all other evaluated parameters, only smoking showed a significant association with the presence of oral lesions. Oral HPV infections may play a role in the pathogenesis of premalignant oral lesions. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Application of a kernel-based online learning algorithm to the classification of nodule candidates in computer-aided detection of CT lung nodules

    International Nuclear Information System (INIS)

    Matsumoto, S.; Ohno, Y.; Takenaka, D.; Sugimura, K.; Yamagata, H.

    2007-01-01

    Classification of the nodule candidates in computer-aided detection (CAD) of lung nodules in CT images was addressed by constructing a nonlinear discriminant function using a kernel-based learning algorithm called the kernel recursive least-squares (KRLS) algorithm. Using the nodule candidates derived from the processing by a CAD scheme of 100 CT datasets containing 253 non-calcified nodules or 3 mm or larger as determined by the consensus of two thoracic radiologists, the following trial were carried out 100 times: by randomly selecting 50 datasets for training, a nonlinear discriminant function was obtained using the nodule candidates in the training datasets and tested with the remaining candidates; for comparison, a rule-based classification was tested in a similar manner. At the number of false positives per case of about 5, the nonlinear classification method showed an improved sensitivity of 80% (mean over the 100 trials) compared with 74% of the rule-based method. (orig.)

  12. Does Computer-aided Detection Assist in the Early Detection of Breast Cancer?

    International Nuclear Information System (INIS)

    Hukkinen, K.; Pamilo, M.

    2005-01-01

    Purpose: To evaluate whether breast cancers detected at screening are visible in previous mammograms, and to assess the performance of a computer-aided detection (CAD) system in detecting lesions in preoperative and previous mammograms. Material and Methods: Initial screening detected 67 women with 69 surgically verified breast cancers (Group A). An experienced screening radiologist retrospectively analyzed previous mammograms for visible lesions (Group B), noting in particular their size and morphology. Preoperative and previous mammograms were analyzed with CAD; a relatively inexperienced resident also analyzed previous mammograms. The performances of CAD and resident were then compared. Results: Of the 69 lesions identified, 36 were visible in previous mammograms. Of these 36 'missed' lesions, 14 were under 10 mm in diameter and 29 were mass lesions. The sensitivity of CAD was 81% in Group A and 64% in Group B. Small mass lesions were harder for CAD to detect. The specificity of CAD was 3% in Group A and 9% in Group B. Together, CAD and the resident found more 'missed' lesions than separately. Conclusion: Of the 69 breast cancers, 36 were visible in previous mammograms. CAD's sensitivity in detecting cancer lesions ranged from 64% to 81%, while specificity ranged from 9% to as low as 3%. CAD may be helpful if the radiologist is less subspecialized in mammography

  13. Real-time MRI navigated US: Role in diagnosis and guided biopsy of incidental breast lesions and axillary lymph nodes detected on breast MRI but not on second look US

    Energy Technology Data Exchange (ETDEWEB)

    Pons, Elena Pastor, E-mail: elenapastorpons@gmail.com; Azcón, Francisco Miras, E-mail: frmiaz00@gmail.com; Casas, María Culiañez, E-mail: mariacc1980@gmail.com; Meca, Salvador Martínez, E-mail: isalvaa@hotmail.com; Espona, José Luis García, E-mail: gespona@hotmail.com

    2014-06-15

    Objectives: To prospectively evaluate the accuracy of real-time ultrasound combined with supine-MRI using volume navigation technique (RtMR-US) in diagnosis and biopsy of incidental breast lesions (ILSM) and axillary lymph nodes (LNSM) suspicious of malignancy on contrast enhanced magnetic resonance imaging (CE-MRI). Materials and methods: Five hundred and seventy-seven women were examined using breast CE-MRI. Those with incidental breast lesions not identified after second-look ultrasound (US) were recruited for RtMR-US. Biopsy was performed in ILSM. Breast lesions were categorized with BI-RADS system and Fisher’ exact test. Axillary lymph nodes morphology was described. To assess efficacy of RtMR-US, diagnostic accuracy, sensitivity, specificity, detection rate and Kappa index of conventional-US and RtMR-US were calculated. Results: Forty-three lesions were detected on CE-MRI before navigation. Eighteen were carcinomas and 25 ILSM. Of these, 21 underwent a RtMR-US. Detection rate on RtMR-US (90.7%) was higher than on conventional-US (43%) (p < 0.001). Agreement between both techniques was low (k = 0.138). Twenty ILSM and 2 LNSM were biopsied. Sixty-five percent were benign (100% of BI-RADS3 and 56% of BI-RADS4-5). Diagnostic performance of RtMR-US identifying malignant nodules for overall lesions and for the subgroup of ILSM was respectively: sensitivity 96.3% and 100%, specificity 18.8% and 30.7%, positive predictive value 66.7% and 43.7%, negative predictive value 75% and 100%. In addition RtMR-US enabled biopsy of 2 metastatic lymph nodes. Conclusions: Real time-US with supine-MRI using a volume navigation technique increases the detection of ILSM. RtMR-US may be used to detect occult breast carcinomas and to assess cancer extension, preventing unnecessary MRI-guided biopsies and sentinel lymph node biopsies. Incidental lesions BI-RADS 3 non-detected on conventional-US are probably benign.

  14. Accuracy of magnetic resonance studies in the detection of chondral and labral lesions in femoroacetabular impingement: systematic review and meta-analysis.

    Science.gov (United States)

    Saied, A M; Redant, C; El-Batouty, M; El-Lakkany, M R; El-Adl, W A; Anthonissen, J; Verdonk, R; Audenaert, E A

    2017-02-16

    Several types of Magnetic resonance imaging (MRI) are commonly used in imaging of femoroacetabular impingement (FAI), however till now there are no clear protocols and recommendations for each type. The aim of this meta-analysis is to detect the accuracy of conventional magnetic resonance imaging (cMRI), direct magnetic resonance arthrography (dMRA) and indirect magnetic resonance arthrography (iMRA) in the diagnosis of chondral and labral lesions in femoroacetabular impingement (FAI). A literature search was finalized on the 17th of May 2016 to collect all studies identifying the accuracy of cMRI, dMRA and iMRA in diagnosing chondral and labral lesions associated with FAI using surgical results (arthroscopic or open) as a reference test. Pooled sensitivity and specificity with 95% confidence intervals using a random-effects meta-analysis for MRI, dMRA and iMRA were calculated also area under receiver operating characteristic (ROC) curve (AUC) was retrieved whenever possible where AUC is equivocal to diagnostic accuracy. The search yielded 192 publications which were reviewed according inclusion and exclusion criteria then 21 studies fulfilled the eligibility criteria for the qualitative analysis with a total number of 828 cases, lastly 12 studies were included in the quantitative meta-analysis. Meta-analysis showed that as regard labral lesions the pooled sensitivity, specificity and AUC for cMRI were 0.864, 0.833 and 0.88 and for dMRA were 0.91, 0.58 and 0.92. While in chondral lesions the pooled sensitivity, specificity and AUC for cMRI were 0.76, 0.72 and 0.75 and for dMRA were 0.75, 0.79 and 0.83, while for iMRA were sensitivity of 0.722 and specificity of 0.917. The present meta-analysis showed that the diagnostic test accuracy was superior for dMRA when compared with cMRI for detection of labral and chondral lesions. The diagnostic test accuracy was superior for labral lesions when compared with chondral lesions in both cMRI and dMRA. Promising results are

  15. Dual contrast enhanced magnetic resonance imaging of the liver with superparamagnetic iron oxide followed by gadolinium for lesion detection and characterization

    International Nuclear Information System (INIS)

    Kubaska, Samantha; Sahani, Dushyant V.; Saini, Sanjay; Hahn, Peter F.; Halpern, Elkan

    2001-01-01

    AIM: Iron oxide contrast agents are useful for lesion detection, and extracellular gadolinium chelates are advocated for lesion characterization. We undertook a study to determine if dual contrast enhanced liver imaging with sequential use of ferumoxides particles and gadolinium (Gd)-DTPA can be performed in the same imaging protocol. MATERIALS AND METHODS: Sixteen patients underwent dual contrast magnetic resonance imaging (MRI) of the liver for evaluation of known/suspected focal lesions which included, metastases (n = 5), hepatocellular carcinoma (HCC;n = 3), cholangiocharcinoma(n = 1) and focal nodular hyperplasia (FNH;n = 3). Pre- and post-iron oxide T1-weighted gradient recalled echo (GRE) and T2-weighted fast spin echo (FSE) sequences were obtained, followed by post-Gd-DTPA (0.1 mmol/kg) multi-phase dynamic T1-weighted out-of-phase GRE imaging. Images were analysed in a blinded fashion by three experts using a three-point scoring system for lesion conspicuity on pre- and post-iron oxide T1 images as well as for reader's confidence in characterizing liver lesions on post Gd-DTPA T1 images. RESULTS: No statistically significant difference in lesion conspicuity was observed on pre- and post-iron oxide T1-GRE images in this small study cohort. The presence of iron oxide did not appreciably diminish image quality of post-gadolinium sequences and did not prevent characterization of liver lesions. CONCLUSION: Our results suggest that characterization of focal liver lesion with Gd-enhanced liver MRI is still possible following iron oxide enhanced imaging. Kubaska, S. et al. (2001)

  16. Fine-needle cytology of breast lesions seen on mammograms

    International Nuclear Information System (INIS)

    Schmidt, R.A.; Ridlen, M.S.; Dowlatshahi, K.; Jokich, P.M.; Bibbo, M.

    1989-01-01

    Stereotactic fine-needle aspiration of nonpalpable breast lesions is operator dependent. The authors have analyzed 250 biopsies at our institution (comparing aspiration cytology with surgical biopsy) for sensitivity, false-negative, and insufficient-sample rates of three different interpreters. Needle aspiration as an alternative to biopsy or a follow-up for lesions of low mammographic suspicion would have resulted in detection of most, but not all, cancers. Over 40 additional biopsies would have been needed to detect each missed cancer. Eighty percent of surgical biopsies would have been needed to detect each missed cancer. Eighty percent of surgical biopsies for low-suspicion lesions could be avoided. Aspiration cytologic series should report separately insufficient samples and LCIS, and should use a consistent threshold for interpreting cytologic results

  17. Black-pigmented anaerobic rods in closed periapical lesions.

    Science.gov (United States)

    Bogen, G; Slots, J

    1999-05-01

    This study determined the frequency of Porphyromonas endodontalis, Porphyromonas gingivalis, Prevotella intermedia and Prevotella nigrescens in 20 closed periapical lesions associated with symptomatic and asymptomatic refractory endodontic disease. To deliniate possible oral sources of P. endodontalis, the presence of the organism was assessed in selected subgingival sites and saliva in the same study patients. Periapical samples were obtained by paper points during surgical endodontic procedures using methods designed to minimize contamination by non-endodontic microorganisms. Subgingival plaque samples were obtained by paper points from three periodontal pockets and from the pocket of the tooth associated with the closed periapical lesion. Unstimulated saliva was collected from the surface of the soft palate. Bacterial identification was performed using a species-specific polymerase chain reaction (PCR) detection method. P. endodontalis was not identified in any periapical lesion, even though subgingival samples from eight patients (40%) revealed the P. endodontalis-specific amplicon. P. gingivalis occurred in one periapical lesion that was associated with moderate pain. P. nigrescens, P. endodontalis and P. intermedia were not detected in any periapical lesion studied. Black-pigmented anaerobic rods appear to be infrequent inhabitants of the closed periapical lesion.

  18. Supine breast US: how to correlate breast lesions from prone MRI.

    Science.gov (United States)

    Telegrafo, Michele; Rella, Leonarda; Stabile Ianora, Amato A; Angelelli, Giuseppe; Moschetta, Marco

    2016-01-01

    To evaluate spatial displacement of breast lesions from prone MR to supine ultrasound positions, and to determine whether the degree of displacement may be associated with breast density and lesion histotype. 380 patients underwent breast MR and second-look ultrasound. The MR and ultrasound lesion location within the breast gland, distances from anatomical landmarks (nipple, skin and pectoral muscle), spatial displacement (distance differences from the landmarks within the same breast region) and region displacement (breast region change) were prospectively evaluated. Differences between MR and ultrasound measurements, association between the degree of spatial displacement and both breast density and lesion histotypes were calculated. In 290/380 (76%) patients, 300 MR lesions were detected. 285/300 (95%) lesions were recognized on ultrasound. By comparing MR and ultrasound, spatial displacement occurred in 183/285 (64.3%) cases while region displacement in 102/285 (35.7%) cases with a circumferential movement along an arc centred on the nipple, having supine ultrasound as the reference standard. A significant association between the degree of lesion displacement and breast density was found (p < 0.00001) with a significant higher displacement in case of fatty breasts. No significant association between the degree of displacement and lesion histotype was found (p = 0.1). Lesion spatial displacement from MRI to ultrasound may occur especially in adipose breasts. Lesion-nipple distance and circumferential displacement from the nipple need to be considered for ultrasound lesion detection. Second-look ultrasound breast lesion detection could be improved by calculating the lesion-nipple distance and considering that spatial displacement from MRI occurs with a circumferential movement along an arc centred on the nipple.

  19. Computerized tomographic evaluation of chronic ischemic lesions in cerebral white matter

    International Nuclear Information System (INIS)

    Yamanouchi, Hiroshi; Tohgi, Hideo; Iio, Masahiro; Tomonaga, Masanori.

    1981-01-01

    The purpose of this study is to clarify the correlation between the low density areas and periventricular lucency (PVL) on CT and the histopathologic changes of chronic ischemic lesions in cerebral white matter. Thirty seven brains from chronic cases with stroke and 17 brains from patients who showed PVLs on CT were examined histologically. CT scans were performed using GE CT/T. Chronic ischemic lesions with severe demyelination or diffuse cavitation were detected as low density areas on CT. But if associated with severe gliosis, those lesions could not be detected on CT. Areas with myelin pallor could not be detected on CT. In some cases diffuse ischemic lesions as demyelination and cavitation were found in the areas corresponding to PVLs on CT. However, they were not always expressed on CT. Other cases with PVL had no histological changes in the frontal white matter. In conclusion, chronic ischemic lesions in the cerebral white matter could not always be detected as low density areas on CT. This may be partly because decreased density due to demyelination and cavitation was counterbalanced by severe gliosis which tends to increase the density. In some cases PVLs were related to diffuse ischemic lesions in the frontal white matter, but this was not always the case. (author)

  20. Wireless capsule endoscopy and proximal small bowel lesions in Crohn’s disease

    Science.gov (United States)

    Petruzziello, Carmelina; Onali, Sara; Calabrese, Emma; Zorzi, Francesca; Ascolani, Marta; Condino, Giovanna; Lolli, Elisabetta; Naccarato, Paola; Pallone, Francesco; Biancone, Livia

    2010-01-01

    AIM: To investigate the prevalence of proximal small bowel (SB) lesions detected by wireless capsule endoscopy (WCE) in Crohn’s disease (CD). METHODS: WCE was performed in 64 patients: 32 with CD of the distal ileum, and 32 controls with iron-deficiency anemia (IDA) or diarrhea. WCE was performed using the Given SB-WCE, followed by small intestine contrast ultrasonography (SICUS). Findings compatible with CD by using WCE included erosions, aphthoid or deep ulcers, and strictures/stenosis. RESULTS: WCE detected proximal SB lesions in 16/32 (50%) patients (14 aphthoid ulcers, 2 deep ulcers, one stricture), which appeared not to be related to clinical parameters [epigastric pain, age, smoking, non-steroidal anti-inflammatory drugs (NSAIDs), IDA]. Among patients with proximal SB lesions, 6 (37%) were smokers, 3 (19%) NSAID users, 3 (19%) had epigastric pain and 4 (25%) had IDA. SICUS detected proximal SB lesions in 3/32 patients (19%) also showing lesions with WCE. No correlations were observed between proximal SB lesions assessed by WCE or by SICUS (χ2 = 1.5, P = 0.2). CONCLUSION: The use of WCE allows the detection of previously unknown upper SB lesions in a high proportion of patients with a previous diagnosis of CD involving the distal ileum. PMID:20614486

  1. Automatic Classification of Specific Melanocytic Lesions Using Artificial Intelligence.

    Science.gov (United States)

    Jaworek-Korjakowska, Joanna; Kłeczek, Paweł

    2016-01-01

    Given its propensity to metastasize, and lack of effective therapies for most patients with advanced disease, early detection of melanoma is a clinical imperative. Different computer-aided diagnosis (CAD) systems have been proposed to increase the specificity and sensitivity of melanoma detection. Although such computer programs are developed for different diagnostic algorithms, to the best of our knowledge, a system to classify different melanocytic lesions has not been proposed yet. In this research we present a new approach to the classification of melanocytic lesions. This work is focused not only on categorization of skin lesions as benign or malignant but also on specifying the exact type of a skin lesion including melanoma, Clark nevus, Spitz/Reed nevus, and blue nevus. The proposed automatic algorithm contains the following steps: image enhancement, lesion segmentation, feature extraction, and selection as well as classification. The algorithm has been tested on 300 dermoscopic images and achieved accuracy of 92% indicating that the proposed approach classified most of the melanocytic lesions correctly. A proposed system can not only help to precisely diagnose the type of the skin mole but also decrease the amount of biopsies and reduce the morbidity related to skin lesion excision.

  2. Nested PCR Assay for Detection of Leishmania donovani in Slit Aspirates from Post-Kala-Azar Dermal Leishmaniasis Lesions

    Science.gov (United States)

    Sreenivas, Gannavaram; Ansari, N. A.; Kataria, Joginder; Salotra, Poonam

    2004-01-01

    A nested PCR assay to detect parasite DNA in slit aspirates from skin lesions of patients with post-kala-azar dermal lesihmaniasis (PKDL) is described. PCR results were positive in 27 of 29 (93%) samples by nested PCR assay, while only 20 of 29 (69%) were positive in a primary PCR assay. The nested PCR assay allowed reliable diagnosis of PKDL in a noninvasive manner. PMID:15071047

  3. Nested PCR Assay for Detection of Leishmania donovani in Slit Aspirates from Post-Kala-Azar Dermal Leishmaniasis Lesions

    OpenAIRE

    Sreenivas, Gannavaram; Ansari, N. A.; Kataria, Joginder; Salotra, Poonam

    2004-01-01

    A nested PCR assay to detect parasite DNA in slit aspirates from skin lesions of patients with post-kala-azar dermal lesihmaniasis (PKDL) is described. PCR results were positive in 27 of 29 (93%) samples by nested PCR assay, while only 20 of 29 (69%) were positive in a primary PCR assay. The nested PCR assay allowed reliable diagnosis of PKDL in a noninvasive manner.

  4. Conspicuity of diffuse axonal injury lesions on diffusion-weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, Toshibumi [Department of Radiology, Division of Neuroradiology, University of Rochester Medical Center, 601 Elmwood Avenue, Box 648, Rochester, NY 14642 (United States)]. E-mail: kino@grape.med.tottori-u.ac.jp; Moritani, Toshio [Department of Radiology, Division of Neuroradiology, University of Rochester Medical Center, 601 Elmwood Avenue, Box 648, Rochester, NY 14642 (United States); Hiwatashi, Akio [Department of Radiology, Division of Neuroradiology, University of Rochester Medical Center, 601 Elmwood Avenue, Box 648, Rochester, NY 14642 (United States); Wang, Henry Z. [Department of Radiology, Division of Neuroradiology, University of Rochester Medical Center, 601 Elmwood Avenue, Box 648, Rochester, NY 14642 (United States); Shrier, David A. [Department of Radiology, Division of Neuroradiology, University of Rochester Medical Center, 601 Elmwood Avenue, Box 648, Rochester, NY 14642 (United States); Numaguchi, Yuji [Department of Radiology, Division of Neuroradiology, University of Rochester Medical Center, 601 Elmwood Avenue, Box 648, Rochester, NY 14642 (United States); Westesson, Per-Lennart A. [Department of Radiology, Division of Neuroradiology, University of Rochester Medical Center, 601 Elmwood Avenue, Box 648, Rochester, NY 14642 (United States)

    2005-10-01

    Objective: (1) To detect diffuse axonal injury (DAI) lesions by diffusion-weighted imaging (DWI), as compared with fluid-attenuated inversion recovery (FLAIR) imaging and (2) to evaluate hemorrhagic DAI lesions by b{sub 0} images obtained from DWI, as compared with gradient-echo (GRE) imaging. Methods: We reviewed MR images of 36 patients with a diagnosis of DAI. MR imaging was performed 20 h to 14 days (mean, 3.7 days) after traumatic brain injury. We evaluated: (1) conspicuity of lesions on DWI and FLAIR and (2) conspicuity of hemorrhage in DAI lesions on b{sub 0} images and GRE imaging. Results: DWI clearly depicted high-signal DAI lesions. The sensitivity of DWI to lesional conspicuity in DAI lesions was almost equal to that of FLAIR. The sensitivity of b{sub 0} images to identification of hemorrhagic DAI lesions was inferior to that of GRE. Conclusion: DWI is as useful as FLAIR in detecting DAI lesions. GRE imaging is still the superior tool for the evaluation of hemorrhagic DAI.

  5. OCT4 and SOX2 are reliable markers in detecting stem cells in odontogenic lesions

    Directory of Open Access Journals (Sweden)

    Abhishek Banerjee

    2016-01-01

    Full Text Available Context (Background: Stem cells are a unique subpopulation of cells in the human body with a capacity to initiate differentiation into various cell lines. Tumor stem cells (TSCs are a unique subpopulation of cells that possess the ability to initiate a neoplasm and sustain self-renewal. Epithelial stem cell (ESC markers such as octamer-binding transcription factor 4 (OCT4 and sex-determining region Y (SRY-box 2 (SOX2 are capable of identifying these stem cells expressed during the early stages of tooth development. Aims: To detect the expression of the stem cell markers OCT4 and SOX2 in the normal odontogenic tissues and the odontogenic cysts and tumors. Materials and Methods: Paraffin sections of follicular tissue, radicular cyst, dentigerous cyst, odontogenic keratocyst, ameloblastoma, adenomatoid odontogenic tumor, and ameloblastic carcinoma were obtained from the archives. The sections were subjected to immunohistochemical assay by the use of mouse monoclonal antibodies to OCT4 and SOX2. Statistical Analysis: The results were evaluated by descriptive analysis. Results: The results show the presence of stem cells in the normal and lesional tissues with these stem cell identifying markers. SOX2 was found to be more consistent and reliable in the detection of stem cells. Conclusion: The stem cell expressions are maintained in the tumor transformation of tissue and probably suggest that there is no phenotypic change of stem cells in progression from normal embryonic state to its tumor component. The quantification and localization reveals interesting trends that indicate the probable role of the cells in the pathogenesis of the lesions.

  6. Histogram-Based Thresholding for Detection and Quantification of Hemorrhages in Retinal Images

    Directory of Open Access Journals (Sweden)

    Hussain Fadhel Hamdan Jaafar

    2016-12-01

    Full Text Available Retinal image analysis is commonly used for the detection and quantification of retinal diabetic retinopathy. In retinal images, dark lesions including hemorrhages and microaneurysms are the earliest warnings of vision loss. In this paper, new algorithm for extraction and quantification of hemorrhages in fundus images is presented. Hemorrhage candidates are extracted in a preliminary step as a coarse segmentation followed by a fine segmentation step. Local variation processes are applied in the coarse segmentation step to determine boundaries of all candidates with distinct edges. Fine segmentation processes are based on histogram thresholding to extract real hemorrhages from the segmented candidates locally. The proposed method was trained and tested using an image dataset of 153 manually labeled retinal images. At the pixel level, the proposed method could identify abnormal retinal images with 90.7% sensitivity and 85.1% predictive value. Due to its distinctive performance measurements, this technique demonstrates that it could be used for a computer-aided mass screening of retinal diseases.

  7. Integrative analysis of gene expression and DNA methylation using unsupervised feature extraction for detecting candidate cancer biomarkers.

    Science.gov (United States)

    Moon, Myungjin; Nakai, Kenta

    2018-04-01

    Currently, cancer biomarker discovery is one of the important research topics worldwide. In particular, detecting significant genes related to cancer is an important task for early diagnosis and treatment of cancer. Conventional studies mostly focus on genes that are differentially expressed in different states of cancer; however, noise in gene expression datasets and insufficient information in limited datasets impede precise analysis of novel candidate biomarkers. In this study, we propose an integrative analysis of gene expression and DNA methylation using normalization and unsupervised feature extractions to identify candidate biomarkers of cancer using renal cell carcinoma RNA-seq datasets. Gene expression and DNA methylation datasets are normalized by Box-Cox transformation and integrated into a one-dimensional dataset that retains the major characteristics of the original datasets by unsupervised feature extraction methods, and differentially expressed genes are selected from the integrated dataset. Use of the integrated dataset demonstrated improved performance as compared with conventional approaches that utilize gene expression or DNA methylation datasets alone. Validation based on the literature showed that a considerable number of top-ranked genes from the integrated dataset have known relationships with cancer, implying that novel candidate biomarkers can also be acquired from the proposed analysis method. Furthermore, we expect that the proposed method can be expanded for applications involving various types of multi-omics datasets.

  8. Imaging pattern of calvarial lesions in adults

    Energy Technology Data Exchange (ETDEWEB)

    Garfinkle, Jarred; Melancon, Denis; Cortes, Maria; Tampieri, Donatella [Montreal Neurological Institute and Hospital-McGill University Health Center, Department of Diagnostic and Interventional Neuroradiology, Montreal, Quebec (Canada)

    2011-10-15

    Calvarial lesions often present themselves as clinically silent findings on skull radiographs or as palpable masses that may cause localized pain or soreness. This review aims to explore the radiographic, computed tomography (CT), and magnetic resonance imaging (MRI) characteristics of calvarial neoplastic, inflammatory, and congenital lesions that are common in adults in order to facilitate a structured approach to their diagnosis and limit the differential diagnosis. In addition to reviewing the literature, we reviewed the records of 141 patients of the Montreal Neurological Institute and Hospital with radiologically documented calvarial lesions between 2001 and June 2009. CT is ideal for detecting bony lesions and is helpful in precisely localizing a lesion pre-surgically. MRI is best at identifying intradiploic lesions before they affect the cortical tables and is able to establish extraosseous involvement, especially when paramagnetic contrast is employed. (orig.)

  9. Cellular and humoral immune responses in sheep vaccinated with candidate antigens MAP2698c and MAP3567 from Mycobacterium avium subspecies paratuberculosis

    Science.gov (United States)

    Gurung, Ratna B.; Purdie, Auriol C.; Whittington, Richard J.; Begg, Douglas J.

    2014-01-01

    Control of Johne's disease, caused by Mycobacterium avium subspecies paratuberculosis (MAP) in ruminants using commercially available vaccine reduces production losses, mortality, fecal shedding and histopathological lesions but does not provide complete protection from infection and interferes with serological diagnosis of Johne's disease and bovine tuberculosis. At this time no recombinant antigens have been found to provide superior protection compared to whole killed or live-attenuated MAP vaccines. Therefore, there is a need to evaluate more candidate MAP antigens. In this study recombinant MAP antigens MAP2698c and MAP3567 were formulated with four different MONTANIDE™ (ISA 50V2, 61VG, 71VG, and 201VG) adjuvants and evaluated for their ability to produce specific immune responses in vaccinated sheep. The cellular immune response was measured with an interferon-gamma (IFN-γ) release assay and the humoral immune response was measured by antibody detection enzyme linked immunosorbent assay. Recombinant vaccine formulation with the antigen MAP2698c and MONTANIDE™ ISA 201VG adjuvant produced strong whole-MAP as well as MAP2698c-specific IFN-γ responses in a high proportion of the vaccinated sheep. The formulation caused less severe injection site lesions in comparison to other formulations. The findings from this study suggest that the MAP2698c + 201VG should be evaluated in a challenge trial to determine the efficacy of this vaccine candidate. PMID:25077074

  10. Significance of angio-CT on diagnosis for hepatocellular carcinoma and precancerous lesions

    International Nuclear Information System (INIS)

    Hatsuse, Kazuo; Aoki, Hideki; Murayama, Michinori; Aihara, Tsukasa; Tsuboi, Kenji; Kakihara, Minoru; Tamakuma, Syoetsu; Irie, Toshiyuki; Terahata, Shintarou

    1994-01-01

    Fifteen patients with space occupying lesions detected by ultrasonography or computed tomography during angiography (angio-CT). Detectability and diagnostic value of angio-CT for intrahepatic tumor were evaluated in comparison with conventional imaging techniques including digital subtraction angiography (DSA), magnetic resonance imaging (MRI) and lipiodol CT (Lp-CT). Twenty-three lesions detected in 15 patients were as follows: 14 hepatocellular carcinoma (HCC), 3 adenomatous hyperplasia (AH), one early hepatocellular carcinoma (eHCC), one atypical adenomatous hyperplasia (AAH), one regenerative nodule, and 3 miscellaneous lesions. With regard to 8 patients with 2 lesions, there were 2 AHs in one patient and 4 patients with advanced HCC had small HCC, eHCC, AH and AAH, respectively. These findings are suggestive of the presence of multicentric carcinogenesis in cirrhosis. The detection rate for intrahepatic tumors was 86.9% with angio-CT, 56.5% with DSA, 71.4% with MRI and 50% with Lp-CT. The detection rate for eHCC, AH and AAH was 80% with angio-CT, and 20% with DSA, MRI and Lp-CT. Angio-CT visualized AH regarded as a precancerous lesion and eHCC more frequently than other imaging techniques. The above mentioned data suggested that there was such a frequent occurrence of multicentric carcinogenesis that recognition of precancerous lesion by angio-CT was important in surgical intervention for HCC with liver cirrhosis. (author)

  11. Comparison of SPECT/CT and MRI in diagnosing symptomatic lesions in ankle and foot pain patients: diagnostic performance and relation to lesion type.

    Science.gov (United States)

    Ha, Seunggyun; Hong, Sung Hwan; Paeng, Jin Chul; Lee, Dong Yeon; Cheon, Gi Jeong; Arya, Amitabh; Chung, June-Key; Lee, Dong Soo; Kang, Keon Wook

    2015-01-01

    The purpose of this study was to compare the diagnostic performance of SPECT/CT and MRI in patients with ankle and foot pain, with regard to the lesion types. Fifty consecutive patients with ankle and foot pain, who underwent 99mTc-MDP SPECT/CT and MRI, were retrospectively enrolled in this study. Symptomatic lesions were determined based on clinical examination and response to treatment. On MRI and SPECT/CT, detected lesions were classified as bone, ligament/tendon, and joint lesions. Uptake on SPECT/CT was assessed using a 4-grade system. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of SPECT/CT and MRI were evaluated in all detected lesions and each lesion type. Diagnostic value of uptake grade was analyzed using receiver-operating characteristics (ROC) curve analysis, and diagnostic performance was compared using Chi-square or McNemar tests. In overall lesions, the sensitivity, PPV and NPV of SPECT/CT for symptomatic lesions were 93%, 56%, 91%, and they were 98%, 48%, 95% for MRI. There was no significant difference between SPECT/CT and MRI. However, the specificity of SPECT/CT was significantly higher than that of MRI (48% versus 24%, P = 0.016). Uptake grade on SPECT/CT was significantly higher in symptomatic lesions (P diagnostic performance for symptomatic lesions in ankle and foot pain patients. SPECT/CT and MRI exhibit different diagnostic specificity in different lesion types. SPECT/CT may be used as a complementary imaging method to MRI for enhancing diagnostic specificity.

  12. Usefulness of US-guided automated gun biopsy of nonpalpable breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Min Sook; Kim, Hak Soo; Lee, Han Kyung; Koh, Sung Hye; O, Eun Young; Yoon, Myung Hwan; Yang, Dal Mo; Kim, Hyung Sik [Chungang Gil Hospital, Incheon (Korea, Republic of)

    1997-11-01

    To evaluate the clinical usefulness of ultrasonography(US)-guided automated gun biopsy of nonpalpable breast lesions. In 30 nonpalpable breast lesions over 0.6cm and detected on US, we performed US-guided biopsy using an 18-gauge automated biopsy gun. Two to four specimens were obtained from each lesion. We analyzed the site, size and depth of the lesions, and the length and histopathologic results of the specimens. In four lesions, surgical biopsy and gun biopsy results were compared. In 29 of 30 lesions(96.7%), specimens were adequate for histopathologic diagnosis, and this was as follows : one case of infiltrating ductal carcinoma, 13 of fibrocystic disease, 10 of fibrocystic disease versus fibroadenoma and one of fibrodenoma. There was also one reactive hyperplasia of LN, and one fatty one and two normal tissues, and in these four lesions, agreement between gun and surgical biopsy results was 100%. The only complication was minor bleeding, which was controlled by compression. US-guided automated gun biopsy is a clinically useful and safe procedure for evaluating nonpalpable breast lesions detected on US.

  13. Usefulness of US-guided automated gun biopsy of nonpalpable breast lesions

    International Nuclear Information System (INIS)

    Kwak, Min Sook; Kim, Hak Soo; Lee, Han Kyung; Koh, Sung Hye; O, Eun Young; Yoon, Myung Hwan; Yang, Dal Mo; Kim, Hyung Sik

    1997-01-01

    To evaluate the clinical usefulness of ultrasonography(US)-guided automated gun biopsy of nonpalpable breast lesions. In 30 nonpalpable breast lesions over 0.6cm and detected on US, we performed US-guided biopsy using an 18-gauge automated biopsy gun. Two to four specimens were obtained from each lesion. We analyzed the site, size and depth of the lesions, and the length and histopathologic results of the specimens. In four lesions, surgical biopsy and gun biopsy results were compared. In 29 of 30 lesions(96.7%), specimens were adequate for histopathologic diagnosis, and this was as follows : one case of infiltrating ductal carcinoma, 13 of fibrocystic disease, 10 of fibrocystic disease versus fibroadenoma and one of fibrodenoma. There was also one reactive hyperplasia of LN, and one fatty one and two normal tissues, and in these four lesions, agreement between gun and surgical biopsy results was 100%. The only complication was minor bleeding, which was controlled by compression. US-guided automated gun biopsy is a clinically useful and safe procedure for evaluating nonpalpable breast lesions detected on US

  14. Assessment of enamel-dentin caries lesions detection using bitewing PSP digital images

    Directory of Open Access Journals (Sweden)

    Marianna Guanaes Gomes Torres

    2011-10-01

    Full Text Available OBJECTIVES: The aim of this study was to evaluate the detection of enamel-dentin occlusal caries using photostimulable phosphor plates. MATERIAL AND METHODS: The ability to detect enamel-dentin occlusal caries in 607 premolars and molars from 47 patients between 10 and 18 years old, referred to the School of Dentistry of the Federal University of Bahia, Brazil, was evaluated based on clinical and radiographic examinations, using the criteria proposed in a previous study. A total of 156 bitewing digital images were obtained using Digora® (Soredex Medical Systems, Helsinki, Finland phosphor plates. The plates were scanned and the images were captured and displayed on a computer screen. Image evaluation was done using Digora® for Windows 2.1 software, Soredex®. The radiologists were allowed to use enhancement tools to obtain better visibility during scoring of the teeth based on the radiographic criteria proposed in a previous study. Descriptive analysis and chi-squared proportion tests were done at 5% significance level. RESULTS: The results of clinical examination showed a higher prevalence of teeth with a straight dark line or demineralization of the occlusal fissure (score 1 and a lower prevalence of sealed teeth (score 5. In the bitewing digital images, 47 teeth presented visible radiolucency, circumscribed, in dentin under occlusal enamel (enamel-dentin caries lesions. CONCLUSIONS: Correlating the clinical and radiographic findings, it was found that in the majority of teeth diagnosed by radiographic images as having enamel-dentin caries, no caries could be detected by clinical examination.

  15. How often do surgeons intervene on shoulder labral lesions detected at MR examination? A retrospective review of MR examinations correlated with arthroscopy

    Science.gov (United States)

    2014-01-01

    Objective: We report the prevalence of surgical intervention on shoulder labral lesions detected at MR examinations and how surgeons describe labral tears seen at MR examinations in their arthroscopy reports. Methods: A retrospective review of 100 consecutive patients aged 50 years or younger who had shoulder labral tears on MR and went on to have surgery performed. It was determined whether surgical intervention was performed on the MR lesions. Results: Of these 100 patients, 72 had superior labral anterior to posterior (SLAP) tears, 38 had posterior labral tears and 28 had anterior labral tears on MR examination. All 100 patients went on to arthroscopy. All lesions described on MRI were described on arthroscopy. Of the 72 SLAP tears, 64 were described as fraying on arthroscopy with 51 debrided. The remaining eight SLAP tears were tacked surgically. Of the 38 posterior labral tears, 36 were described as fraying on arthroscopy with 29 debrided and 2 had surgical tacking performed. Of the 28 anterior labral tears described on MR examination, 26 had surgical tacking performed and 2 were debrided. There were four SLAP tears, two anterior labral tears and three posterior labral tears seen on arthroscopy but not seen on MR examination. Conclusion: In this series, a high percentage of SLAP tears and posterior labral tears described on MR examination did not have surgical tacking. Most anterior labral tears had surgical tacking. Based on the above, our surgeons request we describe superior and posterior labral lesions as fraying and/or tearing, unless we can see a displaced tear. Most anterior labral lesions are treated with surgical tacking. Advances in knowledge: MRI allows for sensitive detection of labral tears. The tears often are not clinically significant. PMID:24712320

  16. Bone resorptive activity in symptomatic and asymptomatic apical lesions of endodontic origin.

    Science.gov (United States)

    Salinas-Muñoz, M; Garrido-Flores, M; Baeza, M; Huamán-Chipana, P; García-Sesnich, J; Bologna, R; Vernal, R; Hernández, M

    2017-11-01

    The aim of this study is to assess the levels and diagnostic accuracy of a set of bone resorption biomarkers, including TRAP-5, RANKL, and OPG in symptomatic and asymptomatic apical lesions and controls. Apical tissues from symptomatic and asymptomatic apical periodontitis patients and periodontal ligaments from healthy teeth extracted for orthodontic reasons were processed for tissue homogenization and the levels of TRAP-5, RANKL, and OPG were determined by multiplex assay. Marker levels were analyzed by Kruskal Wallis test, and diagnostic accuracy was analyzed with ROC curves. Higher levels of RANKL, OPG, and RANKL/OPG ratio were determined in both types of apical lesions compared to healthy periodontal ligament, whereas higher TRAP-5 levels were found only in symptomatic apical lesions (p apical lesions versus healthy controls (AUC = 0.69, p asymptomatic apical periodontitis (AUC = 0.71, p Apical lesions showed higher RANKL and OPG levels than healthy tissues. TRAP-5 levels were the highest in symptomatic apical lesions, suggesting that these represent a progressive state, and showed diagnostic potential. Clinically symptomatic apical periodontitis might represent biologically progressive apical lesions based on TRAP5 levels. TRAP5 has diagnostic potential to identify these lesions, representing a candidate prognostic biomarker.

  17. Role of digital tomosynthesis and dual energy subtraction digital radiography in detection of parenchymal lesions in active pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Sharma, Madhurima; Sandhu, Manavjit Singh; Gorsi, Ujjwal; Gupta, Dheeraj; Khandelwal, Niranjan

    2015-01-01

    Highlights: • Digital tomosynthesis and dual energy subtraction digital radiography are modifications of digital radiography. • These modalities perform better than digital radiography in detection of parenchymal lesions in active pulmonary tuberculosis. • Digital tomosynthesis has a sensitivity of 100% in detection of cavities. • Centrilobular nodules seen on CT in active pulmonary tuberculosis, were also demonstrated on digital tomosynthesis in our study. • Digital tomosynthesis can be used for diagnosis and follow up of patients in pulmonary tuberculosis, thereby reducing the number of CT examinations. - Abstract: Objective: To assess the role of digital tomosynthesis (DTS) and dual energy subtraction digital radiography (DES-DR) in detection of parenchymal lesions in active pulmonary tuberculosis (TB) and to compare them with digital radiography (DR). Materials and methods: This prospective study was approved by our institutional review committee. DTS and DES-DR were performed in 62 patients with active pulmonary TB within one week of multidetector computed tomography (MDCT) study. Findings of active pulmonary TB, that is consolidation, cavitation and nodules were noted on digital radiography (DR), DTS and DES-DR in all patients. Sensitivity, specificity, positive and negative predictive values of all 3 modalities was calculated with MDCT as reference standard. In addition presence of centrilobular nodules was also noted on DTS. Results: Our study comprised of 62 patients (33 males, 29 females with age range 18–82 years). Sensitivity and specificity of DTS for detection of nodules and cavitation was better than DR and DES-DR. Sensitivity and specificity of DTS for detection of consolidation was comparable to DR and DES-DR. DES-DR performed better than DR in detection of nodules and cavitation. DTS was also able to detect centrilobular nodules with sensitivity and specificity of 57.4% and 86.5% respectively. Conclusion: DTS and DES-DR perform better

  18. Role of digital tomosynthesis and dual energy subtraction digital radiography in detection of parenchymal lesions in active pulmonary tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Madhurima, E-mail: madhurimashrm88@gmail.com [Department of Radiodiagnosis and Imaging, PGIMER, Chandigarh 160012 (India); Sandhu, Manavjit Singh, E-mail: manavjitsandhu@yahoo.com [Department of Radiodiagnosis and Imaging, PGIMER, Chandigarh 160012 (India); Gorsi, Ujjwal, E-mail: ujjwalgorsi@gmail.com [Department of Radiodiagnosis and Imaging, PGIMER, Chandigarh 160012 (India); Gupta, Dheeraj, E-mail: dheeraj1910@gmail.com [Department of Pulmonary Medicine, PGIMER, Chandigarh 160012 (India); Khandelwal, Niranjan, E-mail: khandelwaln@hotmail.com [Department of Radiodiagnosis and Imaging, PGIMER, Chandigarh 160012 (India)

    2015-09-15

    Highlights: • Digital tomosynthesis and dual energy subtraction digital radiography are modifications of digital radiography. • These modalities perform better than digital radiography in detection of parenchymal lesions in active pulmonary tuberculosis. • Digital tomosynthesis has a sensitivity of 100% in detection of cavities. • Centrilobular nodules seen on CT in active pulmonary tuberculosis, were also demonstrated on digital tomosynthesis in our study. • Digital tomosynthesis can be used for diagnosis and follow up of patients in pulmonary tuberculosis, thereby reducing the number of CT examinations. - Abstract: Objective: To assess the role of digital tomosynthesis (DTS) and dual energy subtraction digital radiography (DES-DR) in detection of parenchymal lesions in active pulmonary tuberculosis (TB) and to compare them with digital radiography (DR). Materials and methods: This prospective study was approved by our institutional review committee. DTS and DES-DR were performed in 62 patients with active pulmonary TB within one week of multidetector computed tomography (MDCT) study. Findings of active pulmonary TB, that is consolidation, cavitation and nodules were noted on digital radiography (DR), DTS and DES-DR in all patients. Sensitivity, specificity, positive and negative predictive values of all 3 modalities was calculated with MDCT as reference standard. In addition presence of centrilobular nodules was also noted on DTS. Results: Our study comprised of 62 patients (33 males, 29 females with age range 18–82 years). Sensitivity and specificity of DTS for detection of nodules and cavitation was better than DR and DES-DR. Sensitivity and specificity of DTS for detection of consolidation was comparable to DR and DES-DR. DES-DR performed better than DR in detection of nodules and cavitation. DTS was also able to detect centrilobular nodules with sensitivity and specificity of 57.4% and 86.5% respectively. Conclusion: DTS and DES-DR perform better

  19. Automatic Classification of Specific Melanocytic Lesions Using Artificial Intelligence

    Directory of Open Access Journals (Sweden)

    Joanna Jaworek-Korjakowska

    2016-01-01

    Full Text Available Background. Given its propensity to metastasize, and lack of effective therapies for most patients with advanced disease, early detection of melanoma is a clinical imperative. Different computer-aided diagnosis (CAD systems have been proposed to increase the specificity and sensitivity of melanoma detection. Although such computer programs are developed for different diagnostic algorithms, to the best of our knowledge, a system to classify different melanocytic lesions has not been proposed yet. Method. In this research we present a new approach to the classification of melanocytic lesions. This work is focused not only on categorization of skin lesions as benign or malignant but also on specifying the exact type of a skin lesion including melanoma, Clark nevus, Spitz/Reed nevus, and blue nevus. The proposed automatic algorithm contains the following steps: image enhancement, lesion segmentation, feature extraction, and selection as well as classification. Results. The algorithm has been tested on 300 dermoscopic images and achieved accuracy of 92% indicating that the proposed approach classified most of the melanocytic lesions correctly. Conclusions. A proposed system can not only help to precisely diagnose the type of the skin mole but also decrease the amount of biopsies and reduce the morbidity related to skin lesion excision.

  20. Comparison of a conventional cardiac-triggered dual spin-echo and a fast STIR sequence in detection of spinal cord lesions in multiple sclerosis

    International Nuclear Information System (INIS)

    Bot, J.C.J.; Barkhof, F.; Lycklama a Nijeholt, G.J.; Bergers, E.; Castelijns, J.A.; Polman, C.H.; Ader, H.J.

    2000-01-01

    The current optimal imaging protocol in spinal cord MR imaging in patients with multiple sclerosis includes a long TR conventional spin-echo (CSE) sequence, requiring long acquisition times. Using short tau inversion recovery fast spin-echo (fast STIR) sequences both acquisition time can be shortened and sensitivity in the detection of multiple sclerosis (MS) abnormalities can be increased. This study compares both sequences for the potential to detect both focal and diffuse spinal abnormalities. Spinal cords of 5 volunteers and 20 MS patients were studied at 1.0 T. Magnetic resonance imaging included cardiac-gated sagittal dual-echo CSE and a cardiac-gated fast STIR sequence. Images were scored regarding number, size, and location of focal lesions, diffuse abnormalities and presence/hindrance of artifacts by two experienced radiologists. Examinations were scored as being definitely normal, indeterminate, or definitely abnormal. Interobserver agreement regarding focal lesions was higher for CSE (κ=0.67) than for fast STIR (κ=0.57) but did not differ significantly. Of all focal lesions scored in consensus, 47 % were scored on both sequences, 31 % were only detected by fast STIR, and 22 % only by dual-echo CSE (n. s.). Interobserver agreement for diffuse abnormalities was lower with fast STIR (κ=0.48) than dual-echo CSE (κ=0.65; n. s.). After consensus, fast STIR showed in 10 patients diffuse abnormalities and dual-echo CSE in 3. After consensus, in 19 of 20 patients dual-echo CSE scans were considered as definitely abnormal compared with 17 for fast STIR. The fast STIR sequence is a useful adjunct to dual-echo CSE in detecting focal abnormalities and is helpful in detecting diffuse MS abnormalities in the spinal cord. Due to the frequent occurrence of artifacts and the lower observer concordance, fast STIR cannot be used alone. (orig.)

  1. Herpesviruses in asymptomatic apical periodontitis lesions: an immunohistochemical approach.

    Science.gov (United States)

    Saboia-Dantas, C J; Coutrin de Toledo, L F; Sampaio-Filho, H R; Siqueira, J F

    2007-10-01

    Human cytomegalovirus (HCMV) and Epstein-Barr virus (EBV) have been recently detected in samples from apical periodontitis lesions by means of molecular biology techniques and a role in the pathogenesis of this disease has been suggested. The present study was designed to survey asymptomatic primary apical periodontitis lesions for the presence of HCMV- and/or EBV-infected cells by means of immunohistochemistry. Apical periodontitis lesions were obtained from 35 patients [26 human immunodeficiency virus (HIV) -seronegative patients and nine HIV-seropositive patients] after tooth extraction and subjected to immunohistochemical analysis using monoclonal antibodies specific for HCMV and EBV. Fifteen of the 35 apical periodontitis lesions were positive for the target herpesviruses. Overall, EBV was found in 31% of the samples and HCMV in 23%, with 14% of the lesions showing EBV and HCMV dual infection. No association was found between HCMV or EBV with any particular histopathological type of apical periodontitis (P > 0.05). HCMV was significantly more frequent in apical periodontitis lesions from HIV-positive patients (67%) than in lesions from HIV-negative patients (8%) (P = 0.001). EBV was detected in 44% of lesions from HIV-positive patients and in 27% of lesions from HIV-negative patients, but this difference was not significant (P = 0.91). Our results showed that cells infected by HCMV and EBV can be found in apical periodontitis lesions, with a higher prevalence in HIV-positive patients. The specific role that these viruses play in the pathogenesis of apical periodontitis remains to be described.

  2. Detection of rotator cuff lesions with indirect MR angiography

    International Nuclear Information System (INIS)

    Rudolph, J.; Lorenz, M.; Schroeder, R.; Felix, R.

    2000-01-01

    Purpose: To determine the value of indirect MR arthrography in lesions of the rotator cuff, prospectively versus arthroscopy. Methods: 63 patients with suspected shoulder pathology were examined: Oblique-coronary and axial T 1 w sequences, axial FLASH-2 D sequences, furthermore oblique-coronary T 2 - and PD-weighted sequences were taken. After intravenous administration of 0.1 mmol Gd-DTPA/kilogram body weight and active motion of the shoulder T 1 w sequences were repeated. Signal intensities (SI) inside the tendon were quantitatively measured by the ROI technique (region-of-interest) and the percentual contrast-enhancement CE was calculated. In 32 patients the results were confirmed by surgical follow-up. Results: The mean SI measured in the supraspinous tendon were higher in lesions (degeneration, impingement, partial and total rupture), before as well as after contrast medium, compared to intact findings (p [de

  3. Incidental enhancing lesions found on preoperative breast MRI: management and role of second-look ultrasound.

    Science.gov (United States)

    Luciani, M L; Pediconi, F; Telesca, M; Vasselli, F; Casali, V; Miglio, E; Passariello, R; Catalano, C

    2011-09-01

    This study prospectively assessed second-look ultrasound (US) for the evaluation of incidental enhancing lesions identified on preoperative breast magnetic resonance imaging (MRI). Between 2004 and 2007, 182 patients with malignant breast lesions detected on US and/or X-ray mammography and confirmed by cytology/histology underwent preoperative breast contrast-enhanced (CE)-MRI. Patients with incidental lesions on breast MRI underwent second-look high-resolution US directed at the site of the incidental finding. Diagnosis of incidental lesions was based on biopsy or 24-month follow-up. Breast MRI detected 55 additional lesions in 46/182 (25.2%) patients. Forty-two of 55 (76.3%) lesions were detected on second-look US in 38/46 (82.6%) patients. Malignancy was confirmed for 24/42 (57.1%) correlate lesions compared with 7/13 (53.8%) noncorrelate lesions. Second-look US depicted 8/9 (88.8%) Breast Imaging Reporting and Data System (BI-RADS) 5, 16/22 (72.7%) BI-RADS 4 and 18/24 (75%) BI-RADS 3 lesions. Sensitivity, specificity, accuracy and positive and negative predictive values for lesion detection/diagnosis was 100%, 88.9%, 94.6%, 90.3% and 100% for MRI and 64.3%, 70.4%, 67.3%, 69.2% and 65.5% for second-look US. Improved performance for US was obtained when masslike lesions only were considered. Second-look US is a confirmatory method for incidental findings on breast MRI, particularly for mass-like lesions.

  4. Nuclear Magnetic Resonance (NMR Study for the Detection and Quantitation of Cholesterol in HSV529 Therapeutic Vaccine Candidate

    Directory of Open Access Journals (Sweden)

    Rahima Khatun

    Full Text Available This study describes the NMR-based method to determine the limit of quantitation (LOQ and limit of detection (LOD of cholesterol, a process-related impurity in the replication-deficient Herpes Simplex Virus (HSV type 2 candidate vaccine HSV529. Three signature peaks from the 1D 1H NMR of a cholesterol reference spectrum were selected for the identification of cholesterol. The LOQ for a cholesterol working standard was found to be 1 μg/mL, and the LOD was found to be 0.1 μg/mL. The identity of cholesterol, separated from the formulation of growth supplement by thin layer chromatography (TLC, was confirmed by 1D 1H NMR and 2D 1H-13C HSQC NMR. The three signature peaks of cholesterol were detected only in a six-times concentrated sample of HSV529 candidate vaccine sample and not in the single dose HSV529 vaccine sample under similar experimental conditions. Taken together, the results demonstrated that NMR is a direct method that can successfully identify and quantify cholesterol in viral vaccine samples, such as HSV529, and as well as in the growth supplement used during the upstream stages of HSV529 manufacturing. Keywords: Herpes simplex virus type 2 (HSV-2, Viral vaccine, NMR, Residuals, LOD and LOQ, TLC, Growth supplement

  5. A basic study on lesion detectability for hot spot imaging of positron emitters with dedicated PET and positron coincidence gamma camera

    International Nuclear Information System (INIS)

    Zhang, Hong; Inoue, Tomio; Tian, Mei; Alyafei, Saleh; Oriuchi, Noboru; Khan, Nasim; Endo, Keigo; Li Sijin

    2001-01-01

    The aim of this study was to explore the correlations of detectability and the semi-quantification for hot spot imaging with positron emitters in positron emission tomography (PET) and with a positron coincidence detection system (PCD). Phantom study results for the measurement of the lesion-to-background (L/B) ratio ranged from 2.0 to 30.3, and detectability for hot spot lesion of PET and PCD were performed to correspond to clinical conditions. The detectability and semi-quantitative evaluation of hot spots from 4.4 mm to 36.9 mm in diameter were performed from the PET and PCD images. There were strong correlations between the L/B ratios derived from PET and PCD hot spot images and actual L/B ratios; but the L/B ratio derived from PET was higher than that from PCD with a significant difference of 10% to 54.8%. The detectability of hot spot imaging of PCD was lower than that of PET at 64.8% (PCD) versus 77.8% (PET). Even the actual L/B ratio was 8.0, hot spots more than 10.6 mm in diameter could be clearly identified with PCD imaging. The same identification could be achieved with PET imaging even when the actual L/B ratio was 4.0. This detailed investigation indicated that FDG PCD yielded results comparable to FDG PET on visual analysis and semi-quantitative analysis in detecting hot spots in phantoms, but semi-quantitative analysis of the L/B ratio with FDG PCD was inferior to that with FDG PET and the detectability of PCD in smaller hot spots was significantly poor. (author)

  6. Transvaginal sonographic evaluation at different menstrual cycle phases in diagnosis of uterine lesions

    Directory of Open Access Journals (Sweden)

    Hajishaiha M

    2011-10-01

    Full Text Available Masomeh Hajishaiha1, Mohammad Ghasemi-rad2, Nazila Karimpour1, Nikol Mladkova3, Farzaneh Boromand11Department of Gynecology, 2Student Research Committee (SRC, Urmia University of Medical Sciences, Urmia, Islamic Republic of Iran; 3Institute of Cell and Molecular Science, London, UKPurpose: Intrauterine lesions (IULs are a common finding in women of reproductive age, particularly infertile women. Transvaginal sonography (TVS is a popular tool for IUL detection, but there are conflicting data with respect to its accuracy.Methods: Five hundred and six women were enrolled into the study. Of these, 496 underwent hysterosalpingography and subsequent TVS six different times during the course of their menstrual cycle. If a lesion was detected, it was further evaluated by sonohysterography (SHG and hysteroscopy.Results: Of 496 women, 41 were shown to have IULs by TVS and those lesions were confirmed in 39 by SHG and hysteroscopy. All 39 lesions were detectable during the ovulatory and early luteal phase (days 16–19 of the menstrual cycle. Accuracy of TVS during different phases was largely dependent on the size of the lesion. TVS falsely detected two lesions and missed fine adhesions in two patients.Conclusion: Accuracy of TVS in detection of IULs is highly dependent on the menstrual cycle phase, with the ovulatory and early luteal phase being the optimal time for this examination.Keywords: menstrual cycle phase, space occupying lesions, transvaginal sonography

  7. Functional validation of candidate genes detected by genomic feature models

    DEFF Research Database (Denmark)

    Rohde, Palle Duun; Østergaard, Solveig; Kristensen, Torsten Nygaard

    2018-01-01

    to investigate locomotor activity, and applied genomic feature prediction models to identify gene ontology (GO) cate- gories predictive of this phenotype. Next, we applied the covariance association test to partition the genomic variance of the predictive GO terms to the genes within these terms. We...... then functionally assessed whether the identified candidate genes affected locomotor activity by reducing gene expression using RNA interference. In five of the seven candidate genes tested, reduced gene expression altered the phenotype. The ranking of genes within the predictive GO term was highly correlated......Understanding the genetic underpinnings of complex traits requires knowledge of the genetic variants that contribute to phenotypic variability. Reliable statistical approaches are needed to obtain such knowledge. In genome-wide association studies, variants are tested for association with trait...

  8. Noninvasive spectroscopic diagnosis of superficial ocular lesions and corneal infections

    Energy Technology Data Exchange (ETDEWEB)

    Mourant, J.R.; Bigio, I.J.; Johnson, T.; Shimada, T. [Los Alamos National Lab., NM (United States); Gritz, D.C.; Storey-Held, K. [Texas Univ. Health Science Center, San Antonio, TX (United States). Dept. of Ophthalmology

    1994-02-01

    The potential of a rapid noninvasive diagnostic system to detect tissue abnormalities on the surface of the eye has been investigated. The optical scatter signal from lesions and normal areas on the conjunctival sclera of the human eye were measured in vivo. It is possible to distinguish nonpigmented pingueculas from other lesions. The ability of the system to detect malignancies could not be tested because none of the measured and biopsied lesions were malignant. Optical scatter and fluorescence spectra of bacterial and fungal suspensions, and corneal irritations were also collected. Both scattering and fluorescence show potential for diagnosing corneal infections.

  9. Characteristic detected on computed tomography angiography predict coronary artery plaque progression in non-culprit lesions

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Ya Hang; Zhou, Jia Zhou; Zhou, Ying; Yang, Xiaobo; Yang, Jun Jie; Chen, Yun Dai [Dept. of Cardiology, Chinese PLA General Hospital, Beijing (China)

    2017-06-15

    This study sought to determine whether variables detected on coronary computed tomography angiography (CCTA) would predict plaque progression in non-culprit lesions (NCL). In this single-center trial, we analyzed 103 consecutive patients who were undergoing CCTA and percutaneous coronary intervention (PCI) for culprit lesions. Follow-up CCTA was scheduled 12 months after the PCI, and all patients were followed for 3 years after their second CCTA examination. High-risk plaque features and epicardial adipose tissue (EAT) volume were assessed by CCTA. Each NCL stenosis grade was compared visually between two CCTA scans to detect plaque progression, and patients were stratified into two groups based on this. Logistic regression analysis was used to evaluate the factors that were independently associated with plaque progression in NCLs. Time-to-event curves were compared using the log-rank statistic. Overall, 34 of 103 patients exhibited NCL plaque progression (33%). Logistic regression analyses showed that the NCL progression was associated with a history of ST-elevated myocardial infarction (odds ratio [OR] = 5.855, 95% confidence interval [CI] = 1.391–24.635, p = 0.016), follow-up low-density lipoprotein cholesterol level (OR = 6.832, 95% CI = 2.103–22.200, p = 0.001), baseline low-attenuation plaque (OR = 7.311, 95% CI = 1.242–43.028, p = 0.028) and EAT (OR = 1.015, 95% CI = 1.000–1.029, p = 0.044). Following the second CCTA examination, major adverse cardiac events (MACEs) were observed in 12 patients, and NCL plaque progression was significantly associated with future MACEs (log rank p = 0.006). Noninvasive assessment of NCLs by CCTA has potential prognostic value.

  10. Dental lesions in the lowland tapir (Tapirus terrestris)

    DEFF Research Database (Denmark)

    Tjørnelund, Karen B.; Jonsson, Lena M.; Kortegaard, Hanne Ellen

    2015-01-01

    Dental ailments, mandibular swelling, and dentoalveolar abscesses are common in tapirs, but knowledge about prevalence or etiology of these lesions in the Tapiridae family in general, and in lowland tapirs ( Tapirus terrestris ) in particular, is scarce. A recent study identified resorptive lesions...... of unknown etiology as a common problem in the Malayan tapir ( Tapirus indicus ). In order to investigate the type and prevalence of dental lesions occurring in lowland tapirs, and to compare these with findings with the Malayan tapir, skulls and teeth from 46 deceased lowland tapirs were visually...... with associated periapical reaction (15%) and periapical reactions of various degrees without associated detectable dental pathology (13%). All these lesions likely originated from dental trauma. As in Malayan tapirs, juveniles had significantly fewer lesions than adults. This study shows that dental lesions...

  11. Observer training for computer-aided detection of pulmonary nodules in chest radiography.

    Science.gov (United States)

    De Boo, Diederick W; van Hoorn, François; van Schuppen, Joost; Schijf, Laura; Scheerder, Maeke J; Freling, Nicole J; Mets, Onno; Weber, Michael; Schaefer-Prokop, Cornelia M

    2012-08-01

    To assess whether short-term feedback helps readers to increase their performance using computer-aided detection (CAD) for nodule detection in chest radiography. The 140 CXRs (56 with a solitary CT-proven nodules and 84 negative controls) were divided into four subsets of 35; each were read in a different order by six readers. Lesion presence, location and diagnostic confidence were scored without and with CAD (IQQA-Chest, EDDA Technology) as second reader. Readers received individual feedback after each subset. Sensitivity, specificity and area under the receiver-operating characteristics curve (AUC) were calculated for readings with and without CAD with respect to change over time and impact of CAD. CAD stand-alone sensitivity was 59 % with 1.9 false-positives per image. Mean AUC slightly increased over time with and without CAD (0.78 vs. 0.84 with and 0.76 vs. 0.82 without CAD) but differences did not reach significance. The sensitivity increased (65 % vs. 70 % and 66 % vs. 70 %) and specificity decreased over time (79 % vs. 74 % and 80 % vs. 77 %) but no significant impact of CAD was found. Short-term feedback does not increase the ability of readers to differentiate true- from false-positive candidate lesions and to use CAD more effectively. • Computer-aided detection (CAD) is increasingly used as an adjunct for many radiological techniques. • Short-term feedback does not improve reader performance with CAD in chest radiography. • Differentiation between true- and false-positive CAD for low conspicious possible lesions proves difficult. • CAD can potentially increase reader performance for nodule detection in chest radiography.

  12. Detection of intrathoracic infectious lesions using {sup 111}In-diethylenetriamine pentaacetic bicyclic anhydride-IgG ({sup 111}In-DTPA-IgG) scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Tomohiro; Goto, Hajime; Wada, Hiroo; Yuasa, Kazumi; Iguchi, Mari; Okamura, Tatsuru; Ieki, Ryuji; Suzuki, Kenzo [Tokyo Metropolitan Komagome General Hospital (Japan)

    1998-02-01

    The utility of {sup 111}In-DTPA-IgG imaging for the detection of intrathoracic lesions was evaluated in 10 patients with the suspicion of inflammatory or infectious diseases. They were intravenously administered 40 or 80 MBq of {sup 111}In-DTPA-IgG, and scanned after 24 or 48 hours. Of these, 8 cases, consisted of 4 cases with pneumonia and 2 cases with lung abscess and one case of pulmonary tuberculosis and one of a tuberculous pleuritis, showed true positive results. Others were one false negative case of pneumonia and one true negative case of lung cancer. Overall sensitivity and specificity were 88.9% and 100%, respectively. There were no cases which showed side effects or abnormal laboratory findings caused by the radiopharmaceuticals administered. Thus, {sup 111}In-DTPA-IgG imaging is a useful tool for the detection of intrathoracic infectious lesions. (author)

  13. Detection of pathogens from periodontal lesions

    Directory of Open Access Journals (Sweden)

    Malheiros Veruska de João

    2004-01-01

    Full Text Available OBJECTIVE: To comparatively detect A. actinomycetemcomitans and F. nucleatum from periodontal and healthy sites. METHODS: Subgingival clinical samples from 50 periodontitis adult patients and 50 healthy subjects were analyzed. Both organisms were isolated using a trypticase soy agar-bacitracin-vancomycin (TSBV medium and detected by PCR. Conventional biochemical tests were used for bacteria identification. RESULTS: A. actinomycetemcomitans and F. nucleatum were isolated in 18% and 20% of the patients, respectively, and in 2% and 24% of healthy subjects. Among A. actinomycetemcomitans isolates, biotype II was the most prevalent. Primer pair AA was 100% sensitive in the detection of A. actinomycetemcomitans from both subject groups. Primers ASH and FU were also 100% sensitive to detect this organism in healthy subject samples. Primer pair FN5047 was more sensitive to detect F. nucleatum in patients or in healthy samples than primer 5059S. Primers ASH and 5059S were more specific in the detection of A. actinomycetemcomitans and F. nucleatum, respectively, in patients and in healthy subject samples. CONCLUSIONS: PCR is an effective tool for detecting periodontal pathogens in subgingival samples, providing a faster and safer diagnostic tool of periodontal diseases. The method's sensitivity and specificity is conditioned by the choice of the set of primers used.

  14. Impact of model-based iterative reconstruction on low-contrast lesion detection and image quality in abdominal CT: a 12-reader-based comparative phantom study with filtered back projection at different tube voltages

    Energy Technology Data Exchange (ETDEWEB)

    Euler, Andre; Stieltjes, Bram; Eichenberger, Reto; Reisinger, Clemens; Hirschmann, Anna; Zaehringer, Caroline; Kircher, Achim; Streif, Matthias; Bucher, Sabine; Buergler, David; D' Errico, Luigia; Kopp, Sebastien; Wilhelm, Markus [University Hospital Basel, Clinic of Radiology and Nuclear Medicine, Basel (Switzerland); Szucs-Farkas, Zsolt [Hospital Centre of Biel, Institute of Radiology, Biel (Switzerland); Schindera, Sebastian T. [University Hospital Basel, Clinic of Radiology and Nuclear Medicine, Basel (Switzerland); Cantonal Hospital Aarau, Institute of Radiology, Aarau (Switzerland)

    2017-12-15

    To evaluate the impact of model-based iterative reconstruction (MBIR) on image quality and low-contrast lesion detection compared with filtered back projection (FBP) in abdominal computed tomography (CT) of simulated medium and large patients at different tube voltages. A phantom with 45 hypoattenuating lesions was placed in two water containers and scanned at 70, 80, 100, and 120 kVp. The 120-kVp protocol served as reference, and the volume CT dose index (CTDI{sub vol}) was kept constant for all protocols. The datasets were reconstructed with MBIR and FBP. Image noise and contrast-to-noise-ratio (CNR) were assessed. Low-contrast lesion detectability was evaluated by 12 radiologists. MBIR decreased the image noise by 24% and 27%, and increased the CNR by 30% and 29% for the medium and large phantoms, respectively. Lower tube voltages increased the CNR by 58%, 46%, and 16% at 70, 80, and 100 kVp, respectively, compared with 120 kVp in the medium phantom and by 9%, 18% and 12% in the large phantom. No significant difference in lesion detection rate was observed (medium: 79-82%; large: 57-65%; P > 0.37). Although MBIR improved quantitative image quality compared with FBP, it did not result in increased low-contrast lesion detection in abdominal CT at different tube voltages in simulated medium and large patients. (orig.)

  15. Detection and Characterization of Focal Hepatic lesions using Magnetic resonance Imaging

    International Nuclear Information System (INIS)

    Pulgarin, Luis G; Delgado, Jorge Andres; Toro Nancy

    2008-01-01

    A retrospective one year study was performed from June 2006 to June 2007. A total of ten focal liver lesions in 60 patients were examined, describing their magnetic resonance (MR) characteristics, using T1, T2 and dynamic Gd-enhanced T1 weighted sequences with and without fat suppression. Lesions were classified into benign or malignant tumors and a diagnosis was proposed. Specific diagnoses such as simple cyst, abscess, hemangioma, focal nodular hyperplasia, hepatocellular carcinoma, and cholangiocarcinoma were reported.

  16. Diagnostic Accuracy of CBCT with Different Voxel Sizes and Intraoral Digital Radiography for Detection of Periapical Bone Lesions: An Ex-Vivo Study

    Directory of Open Access Journals (Sweden)

    Shirin Sakhdari

    2016-10-01

    Full Text Available Objectives: This study sought to assess the diagnostic accuracy of cone beam computed tomography (CBCT with different voxel sizes and intraoral digital radiography with photostimulable phosphor (PSP plate for detection of periapical (PA bone lesions.Materials and Methods: In this ex vivo diagnostic study, one-millimeter defects were created in the alveolar sockets of 15 bone blocks, each with two posterior teeth. A no-defect control group was also included. Digital PA radiographs with PSP plates and CBCT scans with 200, 250 and 300μ voxel sizes were obtained. Four observers evaluated the possibility of lesion detection using a 5-point scale. Sensitivity, specificity, positive predictive value (PPV and negative predicative value (NPV were analyzed using one-way ANOVA and Tamhane’s post hoc test. Kappa and weighted kappa statistics were applied to assess intraobserver and interobserver agreements.Results: Cochrane Q test showed no significant difference between PSP and CBCT imaging modalities in terms of kappa and weighted kappa statistics (P=0.675. The complete sensitivity and complete NPV for 200 and 250 μ voxel sizes were higher than those of 300 μ voxel size and digital radiography (P<0.001. No significant difference was noted in other parameters among other imaging modalities (P=0.403.Conclusions: The results showed that high-resolution CBCT scans had higher diagnostic accuracy than PSP digital radiography for detection of artificially created PA bone lesions. Voxel size (field of view must be taken into account to minimize patient radiation dose.Keywords: Diagnosis; Cone-Beam Computed Tomography; Radiography, Dental, Digital; Periapical Periodontitis

  17. An Improved Mouse Model of Atopic Dermatitis and Suppression of Skin Lesions by an Inhibitor of Tec Family Kinases

    Directory of Open Access Journals (Sweden)

    Yuko Kawakami

    2007-01-01

    Conclusions: We established a highly efficient, highly reproducible protocol to induce skin lesions in NC/Nga mice and successfully applied it to show the efficacy of terreic acid in treating skin lesions. This mouse model of atopic dermatitis will be useful to study the pathogenetic processes of atopic dermatitis and to evaluate the efficacy of drug candidates.

  18. Effects of automatic tube potential selection on radiation dose index, image quality, and lesion detectability in pediatric abdominopelvic CT and CTA: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Brinkley, Michael F.; Choudhury, Kingshuk Roy; Frush, Donald P. [Duke University School of Medicine, Department of Radiology, DUMC Box 3808, Durham, NC (United States); Ramirez-Giraldo, Juan C. [Siemens Healthcare, Malvern (United States); Samei, Ehsan; Wilson, Joshua M.; Christianson, Olav I. [Duke University School of Medicine, Clinical Imaging Physics Group, Department of Radiology, Durham, NC (United States); Frush, Daniel J. [Duke University School of Medicine, Medical Physics, Durham, NC (United States)

    2016-01-15

    To assess the effect of automatic tube potential selection (ATPS) on radiation dose, image quality, and lesion detectability in paediatric abdominopelvic CT and CT angiography (CTA). A paediatric modular phantom with contrast inserts was examined with routine pitch (1.4) and high pitch (3.0) using a standard abdominopelvic protocol with fixed 120 kVp, and ATPS with variable kVp in non-contrast, contrast-enhanced, and CTA mode. The volume CT dose index (CTDI{sub vol}), contrast-to-noise ratio (CNR) and lesion detectability index (d') were compared between the standard protocol and ATPS examinations. CTDI{sub vol} was reduced in all routine pitch ATPS examinations, with dose reductions of 27-52 % in CTA mode (P < 0.0001), 15-33 % in contrast-enhanced mode (P = 0.0003) and 8-14 % in non-contrast mode (P = 0.03). Iodine and soft tissue insert CNR and d' were improved or maintained in all ATPS examinations. kVp and dose were reduced in 25 % of high pitch ATPS examinations and in none of the full phantom examinations obtained after a single full phantom localizer. ATPS reduces radiation dose while maintaining image quality and lesion detectability in routine pitch paediatric abdominopelvic CT and CTA, but technical factors such as pitch and imaging range must be considered to optimize ATPS benefits. (orig.)

  19. Exposure (mAs) optimisation of a multi-detector CT protocol for hepatic lesion detection: are thinner slices better?

    International Nuclear Information System (INIS)

    Dobeli, Karen L.; Lewis, Sarah J.; Meikle, Steven R.; Brennan, Patrick C.; Thiele, David L.

    2014-01-01

    The purpose of this work was to determine the exposure-optimised slice thickness for hepatic lesion detection with CT. A phantom containing spheres (diameter 9.5, 4.8 and 2.4mm) with CT density 10 HU below the background (50 HU) was scanned at 125, 100, 75 and 50 mAs. Data were reconstructed at 5-, 3- and 1-mm slice thicknesses. Noise, contrast-to-noise ratio (CNR), area under the curve (AUC) as calculated using receiver operating characteristic analysis and sensitivity representing lesion detection were calculated and compared. Compared with the 125 mAs/5mm slice thickness setting, significant reductions in AUC were found for 75 mAs (P<0.01) and 50 mAs (P<0.05) at 1- and 3-mm thicknesses, respectively; sensitivity for the 9.5-mm sphere was significantly reduced for 75 (P<0.05) and 50 mAs (P<0.01) at 1-mm thickness; sensitivity for the 4.8-mm sphere was significantly lower for 100, 75 and 50 mAs at all three slice thicknesses (P<0.05). The 2.4-mm sphere was rarely detected. At each slice thickness, noise at 100, 75 and 50 mAs exposures was approximately 10, 30 and 50% higher, respectively, than that at 125 mAs exposure. CNRs decreased in an irregular manner with reductions in exposure and slice thickness. This study demonstrated no advantage to using slices below 5mm thickness, and consequently thinner slices are not necessarily better.

  20. Oxidative Glial Cell Damage Associated with White Matter Lesions in the Aging Human Brain.

    Science.gov (United States)

    Al-Mashhadi, Sufana; Simpson, Julie E; Heath, Paul R; Dickman, Mark; Forster, Gillian; Matthews, Fiona E; Brayne, Carol; Ince, Paul G; Wharton, Stephen B

    2015-09-01

    White matter lesions (WML) are common in brain aging and are associated with dementia. We aimed to investigate whether oxidative DNA damage and occur in WML and in apparently normal white matter in cases with lesions. Tissue from WML and control white matter from brains with lesions (controls lesional) and without lesions (controls non-lesional) were obtained, using post-mortem magnetic resonance imaging-guided sampling, from the Medical Research Council Cognitive Function and Ageing Study. Oxidative damage was assessed by immunohistochemistry to 8-hydroxy-2'-deoxoguanosine (8-OHdG) and Western blotting for malondialdehyde. DNA response was assessed by phosphorylated histone H2AX (γH2AX), p53, senescence markers and by quantitative Reverse transcription polymerase chain reaction (RT-PCR) panel for candidate DNA damage-associated genes. 8-OHdG was expressed in glia and endothelium, with increased expression in both WML and controls lesional compared with controls non-lesional (P glial dysfunction. Their expression in apparently normal white matter in cases with WML suggests that white matter dysfunction is not restricted to lesions. The role of this field-effect lesion pathogenesis and cognitive impairment are areas to be defined. © 2014 The Authors. Brain Pathology published by John Wiley & Sons Ltd on behalf of International Society of Neuropathology.

  1. Robo-AO Kepler Survey. IV. The Effect of Nearby Stars on 3857 Planetary Candidate Systems

    Science.gov (United States)

    Ziegler, Carl; Law, Nicholas M.; Baranec, Christoph; Riddle, Reed; Duev, Dmitry A.; Howard, Ward; Jensen-Clem, Rebecca; Kulkarni, S. R.; Morton, Tim; Salama, Maïssa

    2018-04-01

    We present the overall statistical results from the Robo-AO Kepler planetary candidate survey, comprising of 3857 high-angular resolution observations of planetary candidate systems with Robo-AO, an automated laser adaptive optics system. These observations reveal previously unknown nearby stars blended with the planetary candidate host stars that alter the derived planetary radii or may be the source of an astrophysical false positive transit signal. In the first three papers in the survey, we detected 440 nearby stars around 3313 planetary candidate host stars. In this paper, we present observations of 532 planetary candidate host stars, detecting 94 companions around 88 stars; 84 of these companions have not previously been observed in high resolution. We also report 50 more-widely separated companions near 715 targets previously observed by Robo-AO. We derive corrected planetary radius estimates for the 814 planetary candidates in systems with a detected nearby star. If planetary candidates are equally likely to orbit the primary or secondary star, the radius estimates for planetary candidates in systems with likely bound nearby stars increase by a factor of 1.54, on average. We find that 35 previously believed rocky planet candidates are likely not rocky due to the presence of nearby stars. From the combined data sets from the complete Robo-AO KOI survey, we find that 14.5 ± 0.5% of planetary candidate hosts have a nearby star with 4″, while 1.2% have two nearby stars, and 0.08% have three. We find that 16% of Earth-sized, 13% of Neptune-sized, 14% of Saturn-sized, and 19% of Jupiter-sized planet candidates have detected nearby stars.

  2. Reliability of cortical lesion detection on double inversion recovery MRI applying the MAGNIMS-Criteria in multiple sclerosis patients within a 16-months period.

    Directory of Open Access Journals (Sweden)

    Tobias Djamsched Faizy

    Full Text Available In patients with multiple sclerosis (MS, Double Inversion Recovery (DIR magnetic resonance imaging (MRI can be used to identify cortical lesions (CL. We sought to evaluate the reliability of CL detection on DIR longitudinally at multiple subsequent time-points applying the MAGNIMs scoring criteria for CLs.26 MS patients received a 3T-MRI (Siemens, Skyra with DIR at 12 time-points (TP within a 16 months period. Scans were assessed in random order by two different raters. Both raters separately marked all CLs on each scan and total lesion numbers were obtained for each scan-TP and patient. After a retrospective re-evaluation, the number of consensus CLs (conL was defined as the total number of CLs, which both raters finally agreed on. CLs volumes, relative signal intensities and CLs localizations were determined. Both ratings (conL vs. non-consensus scoring were compared for further analysis.A total number of n = 334 CLs were identified by both raters in 26 MS patients with a first agreement of both raters on 160 out of 334 of the CLs found (κ = 0.48. After the retrospective re-evaluation, consensus agreement increased to 233 out of 334 CL (κ = 0.69. 93.8% of conL were visible in at least 2 consecutive TP. 74.7% of the conL were visible in all 12 consecutive TP. ConL had greater mean lesion volumes and higher mean signal intensities compared to lesions that were only detected by one of the raters (p<0.05. A higher number of CLs in the frontal, parietal, temporal and occipital lobe were identified by both raters than the number of those only identified by one of the raters (p<0.05.After a first assessment, slightly less than a half of the CL were considered as reliably detectable on longitudinal DIR images. A retrospective re-evaluation notably increased the consensus agreement. However, this finding is narrowed, considering the fact that retrospective evaluation steps might not be practicable in clinical routine. Lesions that were not reliably

  3. X-ray counterpart candidates for six new γ-ray pulsars

    Science.gov (United States)

    Zyuzin, Dmitry A.; Karpova, Anna V.; Shibanov, Yuriy A.

    2018-05-01

    Using archival X-ray data, we have found point-like X-ray counterpart candidates positionally coincident with six γ-ray pulsars discovered recently in the Fermi Gamma-ray Space Telescope data by the Einstein@Home project. The candidates for PSRs J0002+6216, J0554+3107, J1844-0346, and J1105-6037 are detected with Swift, and those for PSRs J0359+5414 and J2017+3625 are detected with Chandra. Despite a low count statistics for some candidates, assuming plausible constraints on the absorbing column density towards the pulsars, we show that X-ray spectral properties for all of them are consistent with those observed for other pulsars. J0359+5414 is the most reliably identified object. We detect a nebula around it, whose spectrum and extent suggest that this is a pulsar wind nebula powered by the pulsar. Associations of J0002+6216 and J1844-0346 with supernova remnants CTB 1 and G28.6-0.1 are proposed.

  4. Retinal Microaneurysms Detection Using Gradient Vector Analysis and Class Imbalance Classification.

    Science.gov (United States)

    Dai, Baisheng; Wu, Xiangqian; Bu, Wei

    2016-01-01

    Retinal microaneurysms (MAs) are the earliest clinically observable lesions of diabetic retinopathy. Reliable automated MAs detection is thus critical for early diagnosis of diabetic retinopathy. This paper proposes a novel method for the automated MAs detection in color fundus images based on gradient vector analysis and class imbalance classification, which is composed of two stages, i.e. candidate MAs extraction and classification. In the first stage, a candidate MAs extraction algorithm is devised by analyzing the gradient field of the image, in which a multi-scale log condition number map is computed based on the gradient vectors for vessel removal, and then the candidate MAs are localized according to the second order directional derivatives computed in different directions. Due to the complexity of fundus image, besides a small number of true MAs, there are also a large amount of non-MAs in the extracted candidates. Classifying the true MAs and the non-MAs is an extremely class imbalanced classification problem. Therefore, in the second stage, several types of features including geometry, contrast, intensity, edge, texture, region descriptors and other features are extracted from the candidate MAs and a class imbalance classifier, i.e., RUSBoost, is trained for the MAs classification. With the Retinopathy Online Challenge (ROC) criterion, the proposed method achieves an average sensitivity of 0.433 at 1/8, 1/4, 1/2, 1, 2, 4 and 8 false positives per image on the ROC database, which is comparable with the state-of-the-art approaches, and 0.321 on the DiaRetDB1 V2.1 database, which outperforms the state-of-the-art approaches.

  5. A qualitative study examining the experience of primary care dentists in the detection and management of potentially malignant lesions. 1. Factors influencing detection and the decision to refer.

    Science.gov (United States)

    Brocklehurst, P R; Baker, S R; Speight, P M

    2010-01-23

    Many oral squamous cell carcinomas present as late stage disease and so the detection of early and pre-malignancy is considered to be of paramount importance. The majority of research examining primary care dentists' experience of the detection and management of early disease has been undertaken using questionnaires, with the inherent bias this introduces. The aim of this study was to use qualitative methods to develop a richer account of practitioners' views about screening and what factors influence the decision to refer a patient. Semi-structured interviews were undertaken with eighteen dentists in Sheffield, transcribed and analysed using thematic analysis. Ten codes were identified according to the aims of the study and organized into four overarching themes. Although many dentists were screening regularly, some did not appear to be adopting a rigorous and systematic approach. A number of participants also placed more reliance on 'classical' presentations rather than the more varied presentation of potentially malignant lesions and were more influenced by the clinical history of the lesion rather than risk factors. Overall, the present research suggests that for some dentists, more rigour is required when examining for early disease.

  6. Contrast-enhanced ultrasound for extrahepatic lesions: preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Thorelius, Lars E-mail: lars@thorelius.com

    2004-06-01

    Ultrasound imaging (US) is a convenient, inexpensive and non-invasive investigation. Its use is limited by low sensitivity in the detection of a number of parenchymal lesions, especially those produced by trauma, such as infarctions. Contrast enhancement with SonoVue{sup [reg]} improves the sensitivity of ultrasound in the detection and characterization of focal liver lesions to such an extent, that it may replace computed tomography (CT) and magnetic resonance imaging (MRI). Preliminary experience suggests that SonoVue-enhanced sonography may be useful in the detection of lesions in which blood flow is severely reduced as compared to surrounding parenchyma, such as infarctions, lacerations, hematomas, necrotic tissue and non-vascular cysts, especially in the spleen, kidney and pancreas. This technique can also rule out occlusion of the superior mesenteric, splenic and portal veins, and dilation of the biliary tree. Clinical trials comparing contrast-enhanced sonography with contrast-enhanced computed tomography are warranted to establish the role of this inexpensive and non-invasive technique in the routine work-up of patients with abdominal trauma or presenting with sudden flank pain.

  7. Immunohistochemical detection of hTERT in urothelial lesions: a potential adjunct to urine cytology

    Directory of Open Access Journals (Sweden)

    Khalbuss Walid

    2006-08-01

    Full Text Available Abstract Background Urine cytology has a critical role in evaluation for bladder carcinoma. Due to the low sensitivity of this technique, ancillary modalities such as the detection of markers of malignancy by immunochemistry are desirable. Promising factors in this context are components of the human telomerase enzyme complex. Telomerase repairs and extend telomeres, which when eroded beyond a critical limit trigger a senescence checkpoint. Accordingly, while absent in normal somatic cells, telomerase activity has been detected in the great majority of malignant tumor specimens tested, and so has potential value for the recognition of malignant cells in clinical specimens. Methods In this study, we investigated whether the immunohistochemical detection of the catalytic subunit of telomerase (hTERT can aid cytology in the diagnosis of bladder lesions. Findings from the retrospective evaluation of over 100 cell blocks, including urine sediments from confirmed malignant and benign conditions, were compared with routine urine cytology data. Results The presence of hTERT protein was indicative of the transformation of urothelia to a malignant phenotype. Nucleolar hTERT was expressed in 27 (93% of 29 samples obtained from patients with confirmed primary bladder cancer. Conversely, hTERT was detectable in only 3 (0.8% of 39 samples from benign conditions. The hTERT assay showed higher diagnostic sensitivity (84.8% than published urine cytology data (~65% for confirmed bladder carcinoma, however, the hTERT assay was less specific than cytology (65.2% vs. ~95% respectively. Conclusion As a highly sensitive marker, immunohistochemical hTERT detection in urine sediments represents a reliable adjunct to cytology in the accurate diagnosis of urothelial neoplasms.

  8. Metastatic Breast Lesion to the Falx Detected with PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, Chester; Schuster, David M. [Emory Univ., Atlanta (United States)

    2012-06-15

    Intracranial dural metastasis is increasingly encountered in imaging. Autopsies conducted on patients with advanced metastatic disease demonstrate dural involvement in 9% of cases, with breast and prostate cancer the most common primaries. Awareness of this entity and imaging appearances is especially important in evaluating malignancies prone to dural metastasis. A 57-year-old woman with a strong family history of breast cancer initially presented after self-detection of a right breast lump. Subsequent mammogram and biopsies yielded a diagnosis of right infiltrating ductal carcinoma with a positive lymph node as well as left invasive lobular carcinoma. Initial staging PET-CT (not shown) at the time of diagnosis demonstrated no abnormal FDG uptake remote from the breast. Neoadjuvant chemotherapy was instituted, and a PET-CT was obtained to evaluate disease response, demonstrating an approximately 1.8 cm hypermetabolic intra-cranial mass, localized to the region of the anterior corpus callosum on axian PET (Fig. 1a), axial fused PET-CT (Fig. 1b), and sagittal fused PET-CT (Fig. 1c) with a maximum SUV of 15.9. There was associated bifrontal vasogenic edema (Fig. 1d) on the CT demonstrated on brain windows. Marked progression of disease was noted elsewhere, including hypermetabolic adenopathy and skeletal disease. A contrast-enhanced MRI of the brain was obtained demonstrating extensive T1 hypointensity, T2, and FLAIR (Fig. 2a) hyperintensity in the bilateral paramedian frontallobes representing vasogenic edema. Post-contrast imaging demonstrated three solidly enhancing masses in the areas of described vasogenic edema, one large extra-axial and two sub-centimeter parenchymal lesions. The large extra-axial and two sub-centimeter parenchymal lesions. The large extra-axial mass demonstrated homogeneous solid enhancement, in the midline anteriorly centered on the falx, just superior to the anterior corpus callosum. This measured 1.7cm transverse x 3.1cm AP x 2.4cm

  9. Microbiome of Deep Dentinal Caries Lesions in Teeth with Symptomatic Irreversible Pulpitis.

    Science.gov (United States)

    Rôças, Isabela N; Alves, Flávio R F; Rachid, Caio T C C; Lima, Kenio C; Assunção, Isauremi V; Gomes, Patrícia N; Siqueira, José F

    2016-01-01

    This study used a next-generation sequencing approach to identify the bacterial taxa occurring in the advanced front of caries biofilms associated with pulp exposure and irreversible pulpitis. Samples were taken from the deepest layer of dentinal caries lesions associated with pulp exposure in 10 teeth diagnosed with symptomatic irreversible pulpitis. DNA was extracted and the microbiome was characterized on the basis of the V4 hypervariable region of the 16S rRNA gene by using paired-end sequencing on Illumina MiSeq device. Bacterial taxa were mapped to 14 phyla and 101 genera composed by 706 different OTUs. Three phyla accounted for approximately 98% of the sequences: Firmicutes, Actinobacteria and Proteobacteria. These phyla were also the ones with most representatives at the species level. Firmicutes was the most abundant phylum in 9/10 samples. As for genera, Lactobacillus accounted for 42.3% of the sequences, followed by Olsenella (13.7%), Pseudoramibacter (10.7%) and Streptococcus (5.5%). Half of the samples were heavily dominated by Lactobacillus, while in the other half lactobacilli were in very low abundance and the most dominant genera were Pseudoramibacter, Olsenella, Streptococcus, and Stenotrophomonas. High bacterial diversity occurred in deep dentinal caries lesions associated with symptomatic irreversible pulpitis. The microbiome could be classified according to the relative abundance of Lactobacillus. Except for Lactobacillus species, most of the highly prevalent and abundant bacterial taxa identified in this study have been commonly detected in infected root canals. The detected taxa can be regarded as candidate pathogens for irreversible pulpitis and possibly the pioneers in pulp invasion to initiate endodontic infection.

  10. Microbiome of Deep Dentinal Caries Lesions in Teeth with Symptomatic Irreversible Pulpitis.

    Directory of Open Access Journals (Sweden)

    Isabela N Rôças

    Full Text Available This study used a next-generation sequencing approach to identify the bacterial taxa occurring in the advanced front of caries biofilms associated with pulp exposure and irreversible pulpitis. Samples were taken from the deepest layer of dentinal caries lesions associated with pulp exposure in 10 teeth diagnosed with symptomatic irreversible pulpitis. DNA was extracted and the microbiome was characterized on the basis of the V4 hypervariable region of the 16S rRNA gene by using paired-end sequencing on Illumina MiSeq device. Bacterial taxa were mapped to 14 phyla and 101 genera composed by 706 different OTUs. Three phyla accounted for approximately 98% of the sequences: Firmicutes, Actinobacteria and Proteobacteria. These phyla were also the ones with most representatives at the species level. Firmicutes was the most abundant phylum in 9/10 samples. As for genera, Lactobacillus accounted for 42.3% of the sequences, followed by Olsenella (13.7%, Pseudoramibacter (10.7% and Streptococcus (5.5%. Half of the samples were heavily dominated by Lactobacillus, while in the other half lactobacilli were in very low abundance and the most dominant genera were Pseudoramibacter, Olsenella, Streptococcus, and Stenotrophomonas. High bacterial diversity occurred in deep dentinal caries lesions associated with symptomatic irreversible pulpitis. The microbiome could be classified according to the relative abundance of Lactobacillus. Except for Lactobacillus species, most of the highly prevalent and abundant bacterial taxa identified in this study have been commonly detected in infected root canals. The detected taxa can be regarded as candidate pathogens for irreversible pulpitis and possibly the pioneers in pulp invasion to initiate endodontic infection.

  11. Adaptive lesion formation using dual mode ultrasound array system

    Science.gov (United States)

    Liu, Dalong; Casper, Andrew; Haritonova, Alyona; Ebbini, Emad S.

    2017-03-01

    We present the results from an ultrasound-guided focused ultrasound platform designed to perform real-time monitoring and control of lesion formation. Real-time signal processing of echogenicity changes during lesion formation allows for identification of signature events indicative of tissue damage. The detection of these events triggers the cessation or the reduction of the exposure (intensity and/or time) to prevent overexposure. A dual mode ultrasound array (DMUA) is used for forming single- and multiple-focus patterns in a variety of tissues. The DMUA approach allows for inherent registration between the therapeutic and imaging coordinate systems providing instantaneous, spatially-accurate feedback on lesion formation dynamics. The beamformed RF data has been shown to have high sensitivity and specificity to tissue changes during lesion formation, including in vivo. In particular, the beamformed echo data from the DMUA is very sensitive to cavitation activity in response to HIFU in a variety of modes, e.g. boiling cavitation. This form of feedback is characterized by sudden increase in echogenicity that could occur within milliseconds of the application of HIFU (see http://youtu.be/No2wh-ceTLs for an example). The real-time beamforming and signal processing allowing the adaptive control of lesion formation is enabled by a high performance GPU platform (response time within 10 msec). We present results from a series of experiments in bovine cardiac tissue demonstrating the robustness and increased speed of volumetric lesion formation for a range of clinically-relevant exposures. Gross histology demonstrate clearly that adaptive lesion formation results in tissue damage consistent with the size of the focal spot and the raster scan in 3 dimensions. In contrast, uncontrolled volumetric lesions exhibit significant pre-focal buildup due to excessive exposure from multiple full-exposure HIFU shots. Stopping or reducing the HIFU exposure upon the detection of such an

  12. Benign Proliferative Breast Lesions and Risk of Cancer

    Directory of Open Access Journals (Sweden)

    Serap Erel

    2010-06-01

    Full Text Available Benign breast lesions (BBL includes a wide variety of histologic entities, which have been broadly classified into non-proliferative lesions, proliferative lesions without atypia, and hyperplasia with atypia. With the increased use of mammography, more benign lesions are being detected, and in order to estimate the risk of breast cancer for specific histologic categories is of great importance to guide clinical management. Women with proliferative lesions without atypia are at slightly increased risk of subsequent breast cancer, whereas women with proliferative lesions with atypia have a higher risk. The risk is 1.5- 2-fold in women with proliferative lesions without atypia, 4-5-fold in women with proliferative lesions with atypia, and 8-10 fold in women with ductal carcinoma in situ. Age at diagnosis of BBL, menopausal status, family history of breast cancer in a first-degree relative, and time since BBL diagnosis on risk of breast cancer are important for risk evaluation. [Archives Medical Review Journal 2010; 19(3.000: 155-167

  13. Multivariate analysis of magnetic resonance imaging of focal hepatic lesions

    International Nuclear Information System (INIS)

    Fujishima, Mamoru; Suemitsu, Ichizou; Sei, Tetsurou; Takeda, Yoshihiro; Hiraki, Yoshio

    1993-01-01

    A total of 124 lesions from 1 to 6 cm in diameter, including 31 cavernous hemangiomas, 32 metastases and 61 hepatocellular carcinomas (HCC) were analyzed to study the usefulness of magnetic resonance imaging (MRI) at 0.5 Tesla to differentiate focal hepatic lesions on the basis of qualitative criteria. Each focal hepatic lesion was assessed for shape, internal architecture and signal intensity relative to normal liver parenchyma. While all cavernous hemangiomas and metastases except one lesion could be detected, detection rate of HCC was significantly inferior to that of the other two diseases. A tumor capsule and a hyperintense focus on T 1 -weighted images were demonstrated in only HCC lesions in strong contrast with the other two diseases; however, metastases with slow-growing characteristics or subacute hematoma may appear as similar images. Cavernous hemangiomas appeared markedly hyperintense on T 2 -weighted images in 23 of 31 lesions, but one metastasis and one HCC had similar images. A multivariate analysis of several MRI resulted in the following mean discriminant scores: cavernous hemangioma, -1.2652; metastasis, 0.1830; and HCC, 0.7138. It appeared to be possible to differentiate the three diseases with 84.4 percent accuracy. (author)

  14. Specialized odorant receptors in social insects that detect cuticular hydrocarbon cues and candidate pheromones.

    Science.gov (United States)

    Pask, Gregory M; Slone, Jesse D; Millar, Jocelyn G; Das, Prithwiraj; Moreira, Jardel A; Zhou, Xiaofan; Bello, Jan; Berger, Shelley L; Bonasio, Roberto; Desplan, Claude; Reinberg, Danny; Liebig, Jürgen; Zwiebel, Laurence J; Ray, Anandasankar

    2017-08-17

    Eusocial insects use cuticular hydrocarbons as components of pheromones that mediate social behaviours, such as caste and nestmate recognition, and regulation of reproduction. In ants such as Harpegnathos saltator, the queen produces a pheromone which suppresses the development of workers' ovaries and if she is removed, workers can transition to a reproductive state known as gamergate. Here we functionally characterize a subfamily of odorant receptors (Ors) with a nine-exon gene structure that have undergone a massive expansion in ants and other eusocial insects. We deorphanize 22 representative members and find they can detect cuticular hydrocarbons from different ant castes, with one (HsOr263) that responds strongly to gamergate extract and a candidate queen pheromone component. After systematic testing with a diverse panel of hydrocarbons, we find that most Harpegnathos saltator Ors are narrowly tuned, suggesting that several receptors must contribute to detection and discrimination of different cuticular hydrocarbons important in mediating eusocial behaviour.Cuticular hydrocarbons (CHC) mediate the interactions between individuals in eusocial insects, but the sensory receptors for CHCs are unclear. Here the authors show that in ants such as H. saltator, the 9-exon subfamily of odorant receptors (HsOrs) responds to CHCs, and ectopic expression of HsOrs in Drosophila neurons imparts responsiveness to CHCs.

  15. An oxygen dependent X-ray lesion in Escherichia coli strain B/r detected by penicillin

    International Nuclear Information System (INIS)

    Gillies, N.E.; Obioha, F.I.; Ratnajothi, N.H.

    1979-01-01

    Enhancement of lethal damage to E. coli B/r by penicillin was observed after X-irradiation under aerobic conditions, but not after exposure to X-rays under anoxia or after U.V. (260 nm) irradiation. No enhancement of damage occurred when incubation with penicillin was delayed for 2 hours after aerobic X-irradiation. This enhancing effect was only detected in this strain and not in the filamentous strain E. coli B. It was concluded that an X-ray induced lesion, sensitive to the presence of oxygen at the time of irradiation and probably located in the cell envelope, initiates filamentation in E. coli B/r, which results in lethal damage in this strain. (author)

  16. Preclinical quantitative MicroPET imaging in evaluation of neuroprotective drug candidates

    International Nuclear Information System (INIS)

    Son, Ji Yeon; Kim, Yu Kyeong; Kim, Ji Sun; Lee, Byung Chul; Kim, Kyeong Min; Choi, Tae Hyun; Cheon, Gi Jeong; Lee, Won Woo; Kim, Sang Eun

    2007-01-01

    Using in vivo molecular imaging with microPET/SPECT has been expected to facilitate drug discovery and development. In this study, we applied quantitative microPET to the preclinical evaluation of the effects of two neuroprotective drug candidates to the nigrostriatal dopaminergic neuronal damage. Fifteen SD rats were divided into three groups. The rats of each group were orally administrated one of neuroprotective candidate; NeuProtec (100mg/kg bid) and SureCero (10mg/kg, qd) or normal saline (0.1ml, qd) for 3 weeks. 6-OHDA was sterotactically placed to the right striatum on eighth day after starting while continuing the medication for additional 14 days. [ 124 I]FP-ClT PET scans were obtained using microPET R4 scanner. The behavioral test by amphetamine-induced rotation and the histological examination after thyrosine hydroxylase (TH) immunohistochemical staining were performed. Different uptake in the lesioned striatum among the groups were demonstrated on [ 124 I]FP-CIT PET images. The rats with NeuProtec showed higher binding in the lesion than controls. No differences were observed in SureCere groups. The FP-CIT uptake in the lesioned striatum was well correlated with the % reduction of TH(+) cells (rho =0.73, p=0.025), and also correlated with rotation test (rho =0.79, p=0.001) [ 124 I]FP-CIT animal PET depicted the neuroprotective effects of NeuProtec to the 6-OHDA neurotoxicity in the rat striatum. No demonstrable effect of SureCero might indicate that inadequate dosage was used in this study. MicroPET imaging with small animal could be a great tool in preclinical evaluation of drug efficacy

  17. Comparison of 3- and 20-Gradient Direction Diffusion-Weighted Imaging in a Clinical Subacute Cohort of Patients with Transient Ischemic Attack: Application of Standard Vendor Protocols for Lesion Detection and Final Infarct Size Projection

    Directory of Open Access Journals (Sweden)

    Inger Havsteen

    2017-12-01

    Full Text Available ObjectiveDiffusion tensor imaging may aid brain ischemia assessment but is more time consuming than conventional diffusion-weighted imaging (DWI. We compared 3-gradient direction DWI (3DWI and 20-gradient direction DWI (20DWI standard vendor protocols in a hospital-based prospective cohort of patients with transient ischemic attack (TIA for lesion detection, lesion brightness, predictability of persisting infarction, and final infarct size.MethodsWe performed 3T-magnetic resonance imaging including diffusion and T2-fluid attenuated inversion recovery (FLAIR within 72 h and 8 weeks after ictus. Qualitative lesion brightness was assessed by visual inspection. We measured lesion area and brightness with manual regions of interest and compared with homologous normal tissue.Results117 patients with clinical TIA showed 78 DWI lesions. 2 lesions showed only on 3DWI. No lesions were uniquely 20DWI positive. 3DWI was visually brightest for 34 lesions. 12 lesions were brightest on 20DWI. The median 3DWI lesion area was larger for lesions equally bright, or brightest on 20DWI [median (IQR 39 (18–95 versus 18 (10–34 mm2, P = 0.007]. 3DWI showed highest measured relative lesion signal intensity [median (IQR 0.77 (0.48–1.17 versus 0.58 (0.34–0.81, P = 0.0006]. 3DWI relative lesion signal intensity was not correlated to absolute signal intensity, but 20DWI performed less well for low-contrast lesions. 3DWI lesion size was an independent predictor of persistent infarction. 3-gradient direction apparent diffusion coefficient areas were closest to 8-week FLAIR infarct size.Conclusion3DWI detected more lesions and had higher relative lesion SI than 20DWI. 20DWI appeared blurred and did not add information.Clinical Trial Registrationhttp://www.clinicaltrials.gov. Unique Identifier NCT01531946.

  18. Gd-EOB-DTPA-enhanced 3.0-Tesla MRI findings for the preoperative detection of focal liver lesions: Comparison with iodine-enhanced multi-detector computed tomography

    Science.gov (United States)

    Park, Hyong-Hu; Goo, Eun-Hoe; Im, In-Chul; Lee, Jae-Seung; Kim, Moon-Jib; Kwak, Byung-Joon; Chung, Woon-Kwan; Dong, Kyung-Rae

    2012-12-01

    The safety of gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic-acid (Gd-EOB-DTPA) has been confirmed, but more study is needed to assess the diagnostic accuracy of Gd-EOB-DTPA-enhanced magnetic resonance imaging (MRI) in patients with a hepatocellular carcinoma (HCC) for whom surgical treatment is considered or with a metastatic hepatoma. Research is also needed to examine the rate of detection of hepatic lesions compared to multi-detector computed tomography (MDCT), which is used most frequently to localize and characterize a HCC. Gd-EOB-DTPA-enhanced MRI and iodine-enhanced MDCT imaging were compared for the preoperative detection of focal liver lesions. The clinical usefulness of each method was examined. The current study enrolled 79 patients with focal liver lesions who preoperatively underwent MRI and MDCT. In these patients, there was less than one month between the two diagnostic modalities. Imaging data were taken before and after contrast enhancement in both methods. To evaluate the images, we analyzed the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) in the lesions and the liver parenchyma. To compare the sensitivity of the two methods, we performed a quantitative analysis of the percentage signal intensity of the liver (PSIL) on a high resolution picture archiving and communication system (PACS) monitor (paired-samples t-test, p DTPA-enhanced MRI findings and the iodine-enhanced MDCT by using an adjusted x2 test. The SNRs, CNRs, and PSIL all had a greater detection rate in Gd-EOB-DTPA enhanced MRI than in iodine-enhanced MDCT. Hepatocyte-selective uptake was observed 20 minutes after the injection in the focal nodular hyperplasia (FNH, 9/9), adenoma (9/10), and highly-differentiated HCC (grade G1, 27/30). Rim enhancement was detected in all metastases (30/30). During the arterial and the delayed phases, good overall agreement between the gadoxetic-acid-enhanced MR and CT was observed (x2 test, p DTPA-enhanced MRI had a higher

  19. Improved detection and biopsy of solid liver lesions using pulse-inversion ultrasound scanning and contrast agent infusion

    DEFF Research Database (Denmark)

    Skjoldbye, B.; Pedersen, Morten Høgholm; Struckmann, J.

    2002-01-01

    The purpose of this study was to assess the ability of pulse-inversion ultrasound (US) scanning (PIUS), combined with an IV contrast agent, to detect malignant liver lesions and its impact on patient management (resectability). Additionally, to determine the feasibility of US-guided biopsy of new...... PIUS-findings at the same session. A total of 30 patients with known or clinically suspected cancer underwent conventional B-mode scanning and PIUS with IV-administered contrast agent. The number of liver metastases in the right and the left liver lobe, respectively, was recorded. All patients...... findings were performed in 17 of 18 patients. All biopsies of additional findings confirmed malignancy. PIUS with an IV contrast agent increased the ability to detect liver metastases compared to conventional US scanning. The technique had a high impact on patient management. The results showed that PIUS...

  20. Predictors of Arrhythmic Events Detected by Implantable Loop Recorders in Renal Transplant Candidates

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Rodrigo Tavares; Martinelli Filho, Martino, E-mail: martino@cardiol.br; Peixoto, Giselle de Lima; Lima, José Jayme Galvão de; Siqueira, Sérgio Freitas de; Costa, Roberto; Gowdak, Luís Henrique Wolff [Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, SP (Brazil); Paula, Flávio Jota de [Unidade de Transplante Renal - Divisão de Urologia do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, SP (Brazil); Kalil Filho, Roberto; Ramires, José Antônio Franchini [Instituto do Coração do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, SP (Brazil)

    2015-11-15

    The recording of arrhythmic events (AE) in renal transplant candidates (RTCs) undergoing dialysis is limited by conventional electrocardiography. However, continuous cardiac rhythm monitoring seems to be more appropriate due to automatic detection of arrhythmia, but this method has not been used. We aimed to investigate the incidence and predictors of AE in RTCs using an implantable loop recorder (ILR). A prospective observational study conducted from June 2009 to January 2011 included 100 consecutive ambulatory RTCs who underwent ILR and were followed-up for at least 1 year. Multivariate logistic regression was applied to define predictors of AE. During a mean follow-up of 424 ± 127 days, AE could be detected in 98% of patients, and 92% had more than one type of arrhythmia, with most considered potentially not serious. Sustained atrial tachycardia and atrial fibrillation occurred in 7% and 13% of patients, respectively, and bradyarrhythmia and non-sustained or sustained ventricular tachycardia (VT) occurred in 25% and 57%, respectively. There were 18 deaths, of which 7 were sudden cardiac events: 3 bradyarrhythmias, 1 ventricular fibrillation, 1 myocardial infarction, and 2 undetermined. The presence of a long QTc (odds ratio [OR] = 7.28; 95% confidence interval [CI], 2.01–26.35; p = 0.002), and the duration of the PR interval (OR = 1.05; 95% CI, 1.02–1.08; p < 0.001) were independently associated with bradyarrhythmias. Left ventricular dilatation (LVD) was independently associated with non-sustained VT (OR = 2.83; 95% CI, 1.01–7.96; p = 0.041). In medium-term follow-up of RTCs, ILR helped detect a high incidence of AE, most of which did not have clinical relevance. The PR interval and presence of long QTc were predictive of bradyarrhythmias, whereas LVD was predictive of non-sustained VT.

  1. Predictors of Arrhythmic Events Detected by Implantable Loop Recorders in Renal Transplant Candidates

    Directory of Open Access Journals (Sweden)

    Rodrigo Tavares Silva

    2015-11-01

    Full Text Available AbstractBackground:The recording of arrhythmic events (AE in renal transplant candidates (RTCs undergoing dialysis is limited by conventional electrocardiography. However, continuous cardiac rhythm monitoring seems to be more appropriate due to automatic detection of arrhythmia, but this method has not been used.Objective:We aimed to investigate the incidence and predictors of AE in RTCs using an implantable loop recorder (ILR.Methods:A prospective observational study conducted from June 2009 to January 2011 included 100 consecutive ambulatory RTCs who underwent ILR and were followed-up for at least 1 year. Multivariate logistic regression was applied to define predictors of AE.Results:During a mean follow-up of 424 ± 127 days, AE could be detected in 98% of patients, and 92% had more than one type of arrhythmia, with most considered potentially not serious. Sustained atrial tachycardia and atrial fibrillation occurred in 7% and 13% of patients, respectively, and bradyarrhythmia and non-sustained or sustained ventricular tachycardia (VT occurred in 25% and 57%, respectively. There were 18 deaths, of which 7 were sudden cardiac events: 3 bradyarrhythmias, 1 ventricular fibrillation, 1 myocardial infarction, and 2 undetermined. The presence of a long QTc (odds ratio [OR] = 7.28; 95% confidence interval [CI], 2.01–26.35; p = 0.002, and the duration of the PR interval (OR = 1.05; 95% CI, 1.02–1.08; p < 0.001 were independently associated with bradyarrhythmias. Left ventricular dilatation (LVD was independently associated with non-sustained VT (OR = 2.83; 95% CI, 1.01–7.96; p = 0.041.Conclusions:In medium-term follow-up of RTCs, ILR helped detect a high incidence of AE, most of which did not have clinical relevance. The PR interval and presence of long QTc were predictive of bradyarrhythmias, whereas LVD was predictive of non-sustained VT.

  2. Predictors of Arrhythmic Events Detected by Implantable Loop Recorders in Renal Transplant Candidates

    Science.gov (United States)

    Silva, Rodrigo Tavares; Martinelli Filho, Martino; Peixoto, Giselle de Lima; de Lima, José Jayme Galvão; de Siqueira, Sérgio Freitas; Costa, Roberto; Gowdak, Luís Henrique Wolff; de Paula, Flávio Jota; Kalil Filho, Roberto; Ramires, José Antônio Franchini

    2015-01-01

    Background The recording of arrhythmic events (AE) in renal transplant candidates (RTCs) undergoing dialysis is limited by conventional electrocardiography. However, continuous cardiac rhythm monitoring seems to be more appropriate due to automatic detection of arrhythmia, but this method has not been used. Objective We aimed to investigate the incidence and predictors of AE in RTCs using an implantable loop recorder (ILR). Methods A prospective observational study conducted from June 2009 to January 2011 included 100 consecutive ambulatory RTCs who underwent ILR and were followed-up for at least 1 year. Multivariate logistic regression was applied to define predictors of AE. Results During a mean follow-up of 424 ± 127 days, AE could be detected in 98% of patients, and 92% had more than one type of arrhythmia, with most considered potentially not serious. Sustained atrial tachycardia and atrial fibrillation occurred in 7% and 13% of patients, respectively, and bradyarrhythmia and non-sustained or sustained ventricular tachycardia (VT) occurred in 25% and 57%, respectively. There were 18 deaths, of which 7 were sudden cardiac events: 3 bradyarrhythmias, 1 ventricular fibrillation, 1 myocardial infarction, and 2 undetermined. The presence of a long QTc (odds ratio [OR] = 7.28; 95% confidence interval [CI], 2.01–26.35; p = 0.002), and the duration of the PR interval (OR = 1.05; 95% CI, 1.02–1.08; p < 0.001) were independently associated with bradyarrhythmias. Left ventricular dilatation (LVD) was independently associated with non-sustained VT (OR = 2.83; 95% CI, 1.01–7.96; p = 0.041). Conclusions In medium-term follow-up of RTCs, ILR helped detect a high incidence of AE, most of which did not have clinical relevance. The PR interval and presence of long QTc were predictive of bradyarrhythmias, whereas LVD was predictive of non-sustained VT. PMID:26351983

  3. Breast vibro-acoustography: initial experience in benign lesions

    International Nuclear Information System (INIS)

    Alizad, Azra; Mehrmohammadi, Mohammad; Ghosh, Karthik; Glazebrook, Katrina N; Carter, Rickey E; Karaberkmez, Leman Gunbery; Whaley, Dana H; Fatemi, Mostafa

    2014-01-01

    Vibro-acoustography (VA) is a newly developed imaging technology that is based on low-frequency vibrations induced in the object by the radiation force of ultrasound. VA is sensitive to the dynamic characteristics of tissue. Here, we evaluate the performance of VA in identifying benign lesions and compare the results to those of mammography. An integrated mammography-VA system designed for in vivo breast imaging was tested on a group of female volunteers, age ≥ 18 years, with suspected breast lesions based on clinical examination. A set of VA scans was acquired after each corresponding mammography. Most lesions were classified as benign based on their histological results. However, in 4 cases, initial diagnosis based on clinical imaging determined that the lesions were cysts. These cysts were aspirated with needle aspiration and disappeared completely under direct ultrasound visualization. Therefore, no biopsies were performed on these cases and lesions were classified as benign based on clinical findings per clinical standards. To define the VA characteristics of benign breast masses, we adopted the features that are normally attributed to such masses in mammography. In a blinded assessment, three radiologists evaluated the VA images independently. The diagnostic accuracy of VA for detection of benign lesions was assessed by comparing the reviewers’ evaluations with clinical data. Out of a total 29 benign lesions in the group, the reviewers were able to locate all lesions on VA images and mammography, 100% with (95% confidence interval (CI): 88% to 100%). Two reviewers were also able to correctly classify 83% (95% CI: 65% to 92%), and the third reviewer 86% (95% CI: 65% to 95%) of lesions, as benign on VA images and 86% (95% CI: 69% to 95%) on mammography. The results suggest that the mammographic characteristics of benign lesion may also be used to identify such lesions in VA. Furthermore, the results show the ability of VA to detect benign breast

  4. Primary (recurrent) and metastatic lesions detection in cervical cancer: A comparison of positron emission tomography, CT and/or MRI image and pathological study

    International Nuclear Information System (INIS)

    Yen, T.C.; Tzen, K.Y.; Ma, S.Y.; Ng, K.K.; Hsueh, S.; Lai, C.H.

    2002-01-01

    Aim: This prospective study is to compare the results of primary (recurrence) and metastatic lesions detection, based on pathologic results, with computed tomography (CT) and/or magnetic resonance imaging (MRI) and positron emission tomography (PET) with [18F]-fluoro-2-deoxy-D-glucose (FDG) in invasive cervical cancer (ICC). Materials and Methods: An FDG PET scan was performed in 136 patients with ICC (107 squamous cell carcinoma [SCC], 18 adenocarcinoma [AdenoCa], 5 adeosquamous cell carcinoma, 4 small cell carcinoma, and 2 poorly differentiated carcinoma; from FIGO staging IB to IVB prior to operation). CT and/or MRI image were performed within one week before or after FDG PET scan was done. The accuracy of lymph node status was based on histological result or a second FDG PET combined with a CT and/or MRI image images. Results: Totally, 68 main tumor and 147 metastatic lesions were recognized by either histopathology or a follow up study. On a lesion basis, CT and/or MRI image images demonstrated 63 (92.6 %) main tumor and 103 (70.1 %) metastatic lesions. For lymph node metastatic lesions detection, there were 6(75 %) enlarged inguinal lymph nodes, 38(76 %) enlarged pelvic lymph nodes (PLN), 28(73.7 %) enlarged para-aortic lymph nodes (PAN), 8(50 %) enlarged supraclavicular lymph nodes (SLNs), and 5(62.5 %) enlarged mediastinal lymph nodes (MLNs). Liver metastases were found in 4(100 %), in lung in 7(70 %) and in bone in 5(83.3 %). Peritoneal metastases were found in 2(28.6 %). FDG PET demonstrated 63 (92.6 %) and 135 (91.8 %) metastatic lesions. For lymph node metastases, FDG PET found 8(100 %) enlarged inguinal lymph nodes, 44(88 %) enlarged PLNs, 36(94.7 %) enlarged PANs, 15(93.8 %) enlarged SLNs, and 8(100 %) enlarged MLNs. Liver metastases were found in 4(100 %), in lung in 9(90 %) and in bone in 6(100 %). Peritoneal metastases were found in 5(71.4 %). On a patient basis, with FDG PET scan, 31(22.8%) were upstaging while 4(2.9%) were down staging. 35

  5. Determining the Effect of Calculus, Hypocalcification, and Stain on Using Optical Coherence Tomography and Polarized Raman Spectroscopy for Detecting White Spot Lesions

    Directory of Open Access Journals (Sweden)

    Amanda Huminicki

    2010-01-01

    Full Text Available Optical coherence tomography (OCT and polarized Raman spectroscopy (PRS have been shown as useful methods for distinguishing sound enamel from carious lesions ex vivo. However, factors in the oral environment such as calculus, hypocalcification, and stain could lead to false-positive results. OCT and PRS were used to investigate extracted human teeth clinically examined for sound enamel, white spot lesion (WSL, calculus, hypocalcification, and stain to determine whether these factors would confound WSL detection with these optical methods. Results indicate that OCT allowed differentiating caries from sound enamel, hypocalcification, and stain, with calculus deposits recognizable on OCT images. ANOVA and post-hoc unequal N HSD analyses to compare the mean Raman depolarization ratios from the various groups showed that the mean values were statistically significant at P<.05, except for several comparison pairs. With the current PRS analysis method, the mean depolarization ratios of stained enamel and caries are not significantly different due to the sloping background in the stained enamel spectra. Overall, calculus and hypocalcification are not confounding factors affecting WSL detection using OCT and PRS. Stain does not influence WSL detection with OCT. Improved PRS analysis methods are needed to differentiate carious from stained enamel.

  6. Can concurrent core biopsy and fine needle aspiration biopsy improve the false negative rate of sonographically detectable breast lesions?

    Directory of Open Access Journals (Sweden)

    Chang Tsai-Wang

    2010-07-01

    Full Text Available Abstract Background The aims of this study were to determine the accuracy of concurrent core needle biopsy (CNB and fine needle aspiration biopsy (FNAB for breast lesions and to estimate the false-negative rate using the two methods combined. Methods Over a seven-year period, 2053 patients with sonographically detectable breast lesions underwent concurrent ultrasound-guided CNB and FNAB. The sonographic and histopathological findings were classified into four categories: benign, indeterminate, suspicious, and malignant. The histopathological findings were compared with the definitive excision pathology results. Patients with benign core biopsies underwent a detailed review to determine the false-negative rate. The correlations between the ultrasonography, FNAB, and CNB were determined. Results Eight hundred eighty patients were diagnosed with malignant disease, and of these, 23 (2.5% diagnoses were found to be false-negative after core biopsy. After an intensive review of discordant FNAB results, the final false-negative rate was reduced to 1.1% (p-value = 0.025. The kappa coefficients for correlations between methods were 0.304 (p-value p-value p-value Conclusions Concurrent CNB and FNAB under ultrasound guidance can provide accurate preoperative diagnosis of breast lesions and provide important information for appropriate treatment. Identification of discordant results using careful radiological-histopathological correlation can reduce the false-negative rate.

  7. The Gaia-ESO Survey: double-, triple-, and quadruple-line spectroscopic binary candidates

    Science.gov (United States)

    Merle, T.; Van Eck, S.; Jorissen, A.; Van der Swaelmen, M.; Masseron, T.; Zwitter, T.; Hatzidimitriou, D.; Klutsch, A.; Pourbaix, D.; Blomme, R.; Worley, C. C.; Sacco, G.; Lewis, J.; Abia, C.; Traven, G.; Sordo, R.; Bragaglia, A.; Smiljanic, R.; Pancino, E.; Damiani, F.; Hourihane, A.; Gilmore, G.; Randich, S.; Koposov, S.; Casey, A.; Morbidelli, L.; Franciosini, E.; Magrini, L.; Jofre, P.; Costado, M. T.; Jeffries, R. D.; Bergemann, M.; Lanzafame, A. C.; Bayo, A.; Carraro, G.; Flaccomio, E.; Monaco, L.; Zaggia, S.

    2017-12-01

    Context. The Gaia-ESO Survey (GES) is a large spectroscopic survey that provides a unique opportunity to study the distribution of spectroscopic multiple systems among different populations of the Galaxy. Aims: Our aim is to detect binarity/multiplicity for stars targeted by the GES from the analysis of the cross-correlation functions (CCFs) of the GES spectra with spectral templates. Methods: We developed a method based on the computation of the CCF successive derivatives to detect multiple peaks and determine their radial velocities, even when the peaks are strongly blended. The parameters of the detection of extrema (DOE) code have been optimized for each GES GIRAFFE and UVES setup to maximize detection. The DOE code therefore allows to automatically detect multiple line spectroscopic binaries (SBn, n ≥ 2). Results: We apply this method on the fourth GES internal data release and detect 354 SBn candidates (342 SB2, 11 SB3, and even one SB4), including only nine SBs known in the literature. This implies that about 98% of these SBn candidates are new because of their faint visual magnitude that can reach V = 19. Visual inspection of the SBn candidate spectra reveals that the most probable candidates have indeed a composite spectrum. Among the SB2 candidates, an orbital solution could be computed for two previously unknown binaries: CNAME 06404608+0949173 (known as V642 Mon) in NGC 2264 and CNAME 19013257-0027338 in Berkeley 81 (Be 81). A detailed analysis of the unique SB4 (four peaks in the CCF) reveals that CNAME 08414659-5303449 (HD 74438) in the open cluster IC 2391 is a physically bound stellar quadruple system. The SB candidates belonging to stellar clusters are reviewed in detail to discard false detections. We suggest that atmospheric parameters should not be used for these system components; SB-specific pipelines should be used instead. Conclusions: Our implementation of an automatic detection of spectroscopic binaries within the GES has allowed the

  8. Ultrasound elastographic techniques in focal liver lesions.

    Science.gov (United States)

    Conti, Clara Benedetta; Cavalcoli, Federica; Fraquelli, Mirella; Conte, Dario; Massironi, Sara

    2016-03-07

    Elastographic techniques are new ultrasound-based imaging techniques developed to estimate tissue deformability/stiffness. Several ultrasound elastographic approaches have been developed, such as static elastography, transient elastography and acoustic radiation force imaging methods, which include point shear wave and shear wave imaging elastography. The application of these methods in clinical practice aims at estimating the mechanical tissues properties. One of the main settings for the application of these tools has been liver stiffness assessment in chronic liver disease, which has been studied mainly using transient elastography. Another field of application for these techniques is the assessment of focal lesions, detected by ultrasound in organs such as pancreas, prostate, breast, thyroid, lymph nodes. Considering the frequency and importance of the detection of focal liver lesions through routine ultrasound, some studies have also aimed to assess the role that elestography can play in studying the stiffness of different types of liver lesions, in order to predict their nature and thus offer valuable non-invasive methods for the diagnosis of liver masses.

  9. Evaluation of accuracy of intra operative imprint cytology for detection of breast lesions

    International Nuclear Information System (INIS)

    Mahmood, Z.; Shahbaz, A.; Qureshi, A.; Aziz, N.; Niazi, S.; Qureshi, S.; Bukhari, M.H.

    2010-01-01

    Objective: To determine the accuracy of imprint cytology as an intraoperative diagnostic procedure for breast lesions with histopathological correlation. Materials and Methods: This was a descriptive study on 40 cases of breast lesions comprising of inflammatory, benign and malignant lesions including their margins etc. It was conducted at King Edward Medical University, Lahore in collaboration with all Surgical Departments of Mayo Hospital. Relevant clinical data was recorded in a proforma. Both touch and scrape imprints were prepared from all the lesions and stained with May-Grunwaled Giemsa and Haematoxylin and Eosin stains. The imprints were subsequently compared with histopathology sections. Results: When we used atypical cases as negative both touch and scrape imprints gave sensitivity, specificity, positive predictive value, negative predictive value and accuracy at 100%. However when we used cases with atypia as positive, sensitivity and negative predictive value were 100% with both touch and scrape imprints. Specificity, positive predictive value and accuracy were 71%, 86%, 85.5% respectively with touch imprints and 78%, 89%, 89% respectively with scrape imprints. No diagnostic difference was noted between the results of both stains. All the imprints were well correlated with histopathological diagnosis. Conclusion: Imprint cytology is an accurate and simple intraoperative method for diagnosing breast lesions. It can provide the surgeons with information regarding immediate clinical and surgical interventions. (author)

  10. Candidate eco-friendly gas mixtures for MPGDs

    Science.gov (United States)

    Benussi, L.; Bianco, S.; Saviano, G.; Muhammad, S.; Piccolo, D.; Ferrini, M.; Parvis, M.; Grassini, S.; Colafranceschi, S.; Kjølbro, J.; Sharma, A.; Yang, D.; Chen, G.; Ban, Y.; Li, Q.

    2018-02-01

    Modern gas detectors for detection of particles require F-based gases for optimal performance. Recent regulations demand the use of environmentally unfriendly F-based gases to be limited or banned. This review studies properties of potential eco-friendly gas candidate replacements.

  11. Sonographic findings of space occupying lesions in liver

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In One; Choi, B I; Kim, J W [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1982-12-15

    Gray scale ultrasonography is used with increasing frequency for the detection and characterization of hepatic space occupying lesions. Authors analyzed sonographic findings of 73 cases of hepatic space occupying lesions,which had been confirmed histologically or diagnosed clinically. The results were summarized as follows: 1. Most common sonographic pattern of hepatic neoplasms was well-defined increased echogenic mass. No significant sonographic difference was noted between primary and metastatic tumor. Splenomegaly and distortion of hepatic echoes favored hepatocellular carcinoma, and multiplicity favored metastatic tumor. 2. Most common sonographic pattern of hepatic abscess was well-defined decreased echogenecity or echoless cystic lesion containing fine low level echoes with posterior enhancement. 3. Hepatic cyst showed sharply defined echoless cystic lesion with strong posterior enhancement

  12. Computed tomographic findings of traumatic intracranial lesions

    International Nuclear Information System (INIS)

    Jeong, Seong Wook; Kim, Il Young; Lee, Byung Ho; Kim, Ki Jeoung; Yoon, Il Gyu

    1985-01-01

    Traumatic intracranial lesion has been one of the most frequent and serious problem in neurosurgical pathology. Computed tomography made it possible to get prompt diagnosis and surgical intervention of intracranial lesions by its safety, fastness and accuracy. Computed tomographic scan was carried out on 1309 cases at Soonchunhyang Chunan Hospital for 15 months from October 1983 to December 1984. We have reviewed the computed tomographic scans of 264 patients which showed traumatic intracranial lesion. The result were as follows: 1. Head trauma was the most frequent diagnosed disease using computed tomographic scans (57.8%) and among 264 cases the most frequent mode of injury was traffic accident (73.9%). 2. Skull fracture was accompanied in frequency of 69.7% and it was detected in CT in 38.6%: depression fracture was more easily detected in 81%. 3. Conutercoup lesion (9.5%) was usually accompanied with temporal and occipital fracture, and it appeared in lower incidence among pediatric group. 4. Intracranial lesions of all 264 cases were generalized cerebral swelling (24.6%), subdural hematoma (22.3%), epidural hematoma (20.8%), intracerebral hematoma (6.1%), and subarachnoid hemorrhage (3.0%). 5. The shape of hematoma was usually biconvex (92.7%) in acute epidural hematoma and cresentic (100%) in acute subdural hematoma, but the most chronic the case became, they showed planoconvex and bicconvex shapes. 6. Extra-axial hematoma was getting decreased in density as time gone by. 7. Hematoma density was not in direct proportion to serum hemoglobin level as single factor

  13. Computed tomographic findings of traumatic intracranial lesions

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Seong Wook; Kim, Il Young; Lee, Byung Ho; Kim, Ki Jeoung; Yoon, Il Gyu [Soonchunhyang University College of Medicine, Seoul (Korea, Republic of)

    1985-10-15

    Traumatic intracranial lesion has been one of the most frequent and serious problem in neurosurgical pathology. Computed tomography made it possible to get prompt diagnosis and surgical intervention of intracranial lesions by its safety, fastness and accuracy. Computed tomographic scan was carried out on 1309 cases at Soonchunhyang Chunan Hospital for 15 months from October 1983 to December 1984. We have reviewed the computed tomographic scans of 264 patients which showed traumatic intracranial lesion. The result were as follows: 1. Head trauma was the most frequent diagnosed disease using computed tomographic scans (57.8%) and among 264 cases the most frequent mode of injury was traffic accident (73.9%). 2. Skull fracture was accompanied in frequency of 69.7% and it was detected in CT in 38.6%: depression fracture was more easily detected in 81%. 3. Conutercoup lesion (9.5%) was usually accompanied with temporal and occipital fracture, and it appeared in lower incidence among pediatric group. 4. Intracranial lesions of all 264 cases were generalized cerebral swelling (24.6%), subdural hematoma (22.3%), epidural hematoma (20.8%), intracerebral hematoma (6.1%), and subarachnoid hemorrhage (3.0%). 5. The shape of hematoma was usually biconvex (92.7%) in acute epidural hematoma and cresentic (100%) in acute subdural hematoma, but the most chronic the case became, they showed planoconvex and bicconvex shapes. 6. Extra-axial hematoma was getting decreased in density as time gone by. 7. Hematoma density was not in direct proportion to serum hemoglobin level as single factor.

  14. MRI monitoring of lesions created at temperature below the boiling point and of lesions created above the boiling point using high intensity focused ultrasound

    OpenAIRE

    Damianou, C.; Ioannides, K.; Hadjisavvas, V.; Mylonas, N.; Couppis, A.; Iosif, D.; Kyriacou, P. A.

    2010-01-01

    Magnetic Resonance Imaging (MRI) was utilized to monitor lesions created at temperature below the boiling point and lesions created at temperature above the boiling point using High Intensity Focused Ultrasound (HIFU) in freshly excised kidney, liver and brain and in vivo rabbit kidney and brain. T2-weighted fast spin echo (FSE) was proven as an excellent MRI sequence that can detect lesions with temperature above the boiling point in kidney. This advantage is attributed to the significant di...

  15. Identification of novel candidate target genes in amplicons of Glioblastoma multiforme tumors detected by expression and CGH microarray profiling

    Directory of Open Access Journals (Sweden)

    Hernández-Moneo Jose-Luis

    2006-09-01

    Full Text Available Abstract Background Conventional cytogenetic and comparative genomic hybridization (CGH studies in brain malignancies have shown that glioblastoma multiforme (GBM is characterized by complex structural and numerical alterations. However, the limited resolution of these techniques has precluded the precise identification of detailed specific gene copy number alterations. Results We performed a genome-wide survey of gene copy number changes in 20 primary GBMs by CGH on cDNA microarrays. A novel amplicon at 4p15, and previously uncharacterized amplicons at 13q32-34 and 1q32 were detected and are analyzed here. These amplicons contained amplified genes not previously reported. Other amplified regions containg well-known oncogenes in GBMs were also detected at 7p12 (EGFR, 7q21 (CDK6, 4q12 (PDGFRA, and 12q13-15 (MDM2 and CDK4. In order to identify the putative target genes of the amplifications, and to determine the changes in gene expression levels associated with copy number change events, we carried out parallel gene expression profiling analyses using the same cDNA microarrays. We detected overexpression of the novel amplified genes SLA/LP and STIM2 (4p15, and TNFSF13B and COL4A2 (13q32-34. Some of the candidate target genes of amplification (EGFR, CDK6, MDM2, CDK4, and TNFSF13B were tested in an independent set of 111 primary GBMs by using FISH and immunohistological assays. The novel candidate 13q-amplification target TNFSF13B was amplified in 8% of the tumors, and showed protein expression in 20% of the GBMs. Conclusion This high-resolution analysis allowed us to propose novel candidate target genes such as STIM2 at 4p15, and TNFSF13B or COL4A2 at 13q32-34 that could potentially contribute to the pathogenesis of these tumors and which would require futher investigations. We showed that overexpression of the amplified genes could be attributable to gene dosage and speculate that deregulation of those genes could be important in the development

  16. Detection and monitoring of early caries lesions

    DEFF Research Database (Denmark)

    Pretty, I A; Ekstrand, K R

    2016-01-01

    and co-workers from 2013 and this still represents the current state of the science in relation to caries detection and monitoring. The review described among others, visible detection systems, image-based detection systems and point-measurement approaches. RESULTS: The current evidence base suggests...... that while there are numerous devices or technology-enabled detection systems, the use of a careful, methodical visual inspection of clean, dry teeth, supplemented where indicated by radiographic views, remains the standard of care in caries detection and diagnostics. Further, it is possible by means...... to the clinician and the patient for whom it may be a useful educational and motivational tool. CONCLUSIONS: Recommendations are presented that can be adopted and adapted to local circumstances and that are both substantiated by evidence and promote a clear, simple and consistent approach to caries detection...

  17. Low tube voltage CT for improved detection of pancreatic cancer: detection threshold for small, simulated lesions

    International Nuclear Information System (INIS)

    Holm, Jon; Loizou, Louiza; Albiin, Nils; Kartalis, Nikolaos; Leidner, Bertil; Sundin, Anders

    2012-01-01

    Pancreatic ductal adenocarcinoma is associated with dismal prognosis. The detection of small pancreatic tumors which are still resectable is still a challenging problem. The aim of this study was to investigate the effect of decreasing the tube voltage from 120 to 80 kV on the detection of pancreatic tumors. Three scanning protocols was used; one using the standard tube voltage (120 kV) and current (160 mA) and two using 80 kV but with different tube currents (500 and 675 mA) to achieve equivalent dose (15 mGy) and noise (15 HU) as that of the standard protocol. Tumors were simulated into collected CT phantom images. The attenuation in normal parenchyma at 120 kV was set at 130 HU, as measured previously in clinical examinations, and the tumor attenuation was assumed to differ 20 HU and was set at 110HU. By scanning and measuring of iodine solution with different concentrations the corresponding tumor and parenchyma attenuation at 80 kV was found to be 185 and 219 HU, respectively. To objectively evaluate the differences between the three protocols, a multi-reader multi-case receiver operating characteristic study was conducted, using three readers and 100 cases, each containing 0–3 lesions. The highest reader averaged figure-of-merit (FOM) was achieved for 80 kV and 675 mA (FOM = 0,850), and the lowest for 120 kV (FOM = 0,709). There was a significant difference between the three protocols (p < 0,0001), when making an analysis of variance (ANOVA). Post-hoc analysis (students t-test) shows that there was a significant difference between 120 and 80 kV, but not between the two levels of tube currents at 80 kV. We conclude that when decreasing the tube voltage there is a significant improvement in tumor conspicuity

  18. Lesion progression in post-treatment persistent endodontic lesions.

    Science.gov (United States)

    Yu, Victoria Soo Hoon; Messer, Harold Henry; Shen, Liang; Yee, Robert; Hsu, Chin-ying Stephen

    2012-10-01

    Radiographic lesions related to root-filled teeth may persist for long periods after treatment and are considered to indicate failure of initial treatment. Persistent lesions are found in a proportion of cases, but information on lesion progression is lacking. This study examined the incidence of lesion improvement, remaining unchanged, and deterioration among persistent lesions in a group of patients recruited from a university-based clinic and identified potential predictors for lesion progression. Patients of a university clinic with persistent endodontic lesions at least 4 years since treatment and with original treatment radiographs available were recruited with informed consent. Data were obtained by interview and from dental records and clinical and radiographic examinations. Univariate and multivariate statistical analyses were carried out by using SPSS (version 19). One hundred fifty-one persistent lesions were identified in 114 patients. A majority of the lesions (107, 70.9%) received treatment between 4 and 5 years prior. Eighty-six lesions (57.0%) improved, 18 (11.9%) remained unchanged, and 47 (31.1%) deteriorated since treatment. Potential predictors for lesions that did not improve included recall lesion size, pain on biting at recall examination, history of a postobturation flare-up, and a non-ideal root-filling length (P < .05). Lesions that had persisted for a longer period appeared less likely to be improving (relative risk, 1.038; 95% confidence interval, 1.000-1.077). A specific time interval alone should not be used to conclude that a lesion will not resolve without intervention. This study identified several clinical factors that are associated with deteriorating persistent lesions, which should aid in identifying lesions that require further intervention. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  19. Photoacoustic detection and optical spectroscopy of high-intensity focused ultrasound-induced thermal lesions in biologic tissue

    Energy Technology Data Exchange (ETDEWEB)

    Alhamami, Mosa; Kolios, Michael C.; Tavakkoli, Jahan, E-mail: jtavakkoli@ryerson.ca [Department of Physics, Ryerson University, 350 Victoria Street, Toronto, Ontario M5B 2K3 (Canada)

    2014-05-15

    Purpose: The aims of this study are: (a) to investigate the capability of photoacoustic (PA) method in detecting high-intensity focused ultrasound (HIFU) treatments in muscle tissuesin vitro; and (b) to determine the optical properties of HIFU-treated and native tissues in order to assist in the interpretation of the observed contrast in PA detection of HIFU treatments. Methods: A single-element, spherically concaved HIFU transducer with a centre frequency of 1 MHz was utilized to create thermal lesions in chicken breast tissuesin vitro. To investigate the detectability of HIFU treatments photoacoustically, PA detection was performed at 720 and 845 nm on seven HIFU-treated tissue samples. Within each tissue sample, PA signals were acquired from 22 locations equally divided between two regions of interest within two volumes in tissue – a HIFU-treated volume and an untreated volume. Optical spectroscopy was then carried out on 10 HIFU-treated chicken breast specimens in the wavelength range of 500–900 nm, in 1-nm increments, using a spectrophotometer with an integrating sphere attachment. The authors’ optical spectroscopy raw data (total transmittance and diffuse reflectance) were used to obtain the optical absorption and reduced scattering coefficients of HIFU-induced thermal lesions and native tissues by employing the inverse adding-doubling method. The aforementioned interaction coefficients were subsequently used to calculate the effective attenuation coefficient and light penetration depth of HIFU-treated and native tissues in the wavelength range of 500–900 nm. Results: HIFU-treated tissues produced greater PA signals than native tissues at 720 and 845 nm. At 720 nm, the averaged ratio of the peak-to-peak PA signal amplitude of HIFU-treated tissue to that of native tissue was 3.68 ± 0.25 (mean ± standard error of the mean). At 845 nm, the averaged ratio of the peak-to-peak PA signal amplitude of HIFU-treated tissue to that of native tissue was 3.75

  20. Differences in the location and activity of intestinal Crohn's disease lesions between adult and paediatric patients detected with MRI

    International Nuclear Information System (INIS)

    Maccioni, Francesca; Carrozzo, Federica; Pino, Anna Rosaria; Staltari, Ilaria; Ansari, Najwa Al; Marini, Mario; Viola, Franca; Di Nardo, Giovanni; Cucchiara, Salvatore; Vestri, Annarita; Signore, Alberto

    2012-01-01

    To prospectively compare paediatric patients (PP) and adult patients (AP) affected by Crohn's disease (CD) in terms of the location and activity of intestinal lesions. Forty-three children (mean age 15 years) and 43 adults (mean age 48 years) with proven CD underwent magnetic resonance enterography (MRE) to localise lesions and detect their activity in 9 segments of the small and large bowel. The results were analysed on a per patient and per segment basis. Ileo-colonoscopy was performed in all patients. P values less than 0.05 were considered statistically significant. Involvement of terminal ileum was significantly different in the two groups: observed in 100 % of AP (43/43) versus 58 % (23/43) of PP (P < 0.0001). Conversely, the colon was diseased in 84 % of PP versus 64 % of AP. In particular, left colonic segments were significantly more involved in PP (descending colon 53 % versus 21 %, P < 0.01; rectum 67 % versus 23 %, P < 0.0001; sigmoid colon 56 % versus 37 %, not significant), whereas caecal involvement was equal in both groups. In children the maximal disease activity was found in left colonic segments, whereas in adults it was in the terminal ileum. MRE detected significant differences between the two populations, showing a more extensive and severe involvement of the left colon in children but the distal ileum in adults. (orig.)

  1. Clinical and radiographic assessment of approximal carious lesions

    International Nuclear Information System (INIS)

    Espelid, I.; Tveit, A.B.

    1986-01-01

    The aim of the study was to compare the radiographic diagnosis of approximal carious lesions with visual observations of the approximal surfaces and within drilled Class II cavities (made into the pulp). Sound (n=28) and carious (n=123) approximal surfaces of extracted premolars and molars were radiographed. The radiographs were studied by seven observers to diagnose caries. Lesions without cavitation were most often classified as sound (61.3%). When lesions had cavities, the rate of detection increased to 89.1%. Sound surfaces were erroneously classified as carious in 15.7% of cases. Statistically, about 6 our of every 10 qualitative assessments of lesion depth on the basis of radiographs, correctly recorded lesions as being in enamel or extending into dentin. The interexaminer variation in radiographic caries diagnosis were mostly due to difference in diagnostic criteria, whereas differences in diagnostic capability were less important

  2. GLP-1 improves neuropathology after murine cold lesion brain trauma

    DEFF Research Database (Denmark)

    DellaValle, Brian; Hempel, Casper; Johansen, Flemming Fryd

    2014-01-01

    brain trauma. METHODS: Severe trauma was induced with a stereotactic cryo-lesion in mice and thereafter treated with vehicle, liraglutide, or liraglutide + GLP-1 receptor antagonist. A therapeutic window was established and lesion size post-trauma was determined. Reactive oxygen species were visualized......-neurodegenerative proteins increased with Lira-driven CREB activation. INTERPRETATION: These results show that Lira has potent effects after experimental trauma in mice and thus should be considered a candidate for critical care intervention post-injury. Moreover, activation of CREB in the brain by Lira - described......OBJECTIVES: In this study, we address a gap in knowledge regarding the therapeutic potential of acute treatment with a glucagon-like peptide-1 (GLP-1) receptor agonist after severe brain trauma. Moreover, it remains still unknown whether GLP-1 treatment activates the protective, anti...

  3. Segmentation of multiple sclerosis lesions in MR images: a review

    International Nuclear Information System (INIS)

    Mortazavi, Daryoush; Kouzani, Abbas Z.; Soltanian-Zadeh, Hamid

    2012-01-01

    Multiple sclerosis (MS) is an inflammatory demyelinating disease that the parts of the nervous system through the lesions generated in the white matter of the brain. It brings about disabilities in different organs of the body such as eyes and muscles. Early detection of MS and estimation of its progression are critical for optimal treatment of the disease. For diagnosis and treatment evaluation of MS lesions, they may be detected and segmented in Magnetic Resonance Imaging (MRI) scans of the brain. However, due to the large amount of MRI data to be analyzed, manual segmentation of the lesions by clinical experts translates into a very cumbersome and time consuming task. In addition, manual segmentation is subjective and prone to human errors. Several groups have developed computerized methods to detect and segment MS lesions. These methods are not categorized and compared in the past. This paper reviews and compares various MS lesion segmentation methods proposed in recent years. It covers conventional methods like multilevel thresholding and region growing, as well as more recent Bayesian methods that require parameter estimation algorithms. It also covers parameter estimation methods like expectation maximization and adaptive mixture model which are among unsupervised techniques as well as kNN and Parzen window methods that are among supervised techniques. Integration of knowledge-based methods such as atlas-based approaches with Bayesian methods increases segmentation accuracy. In addition, employing intelligent classifiers like Fuzzy C-Means, Fuzzy Inference Systems, and Artificial Neural Networks reduces misclassified voxels. (orig.)

  4. Segmentation of multiple sclerosis lesions in MR images: a review

    Energy Technology Data Exchange (ETDEWEB)

    Mortazavi, Daryoush; Kouzani, Abbas Z. [Deakin University, School of Engineering, Geelong, Victoria (Australia); Soltanian-Zadeh, Hamid [Henry Ford Health System, Image Analysis Laboratory, Radiology Department, Detroit, MI (United States); University of Tehran, Control and Intelligent Processing Center of Excellence (CIPCE), School of Electrical and Computer Engineering, Tehran (Iran, Islamic Republic of); School of Cognitive Sciences, Institute for Studies in Theoretical Physics and Mathematics (IPM), Tehran (Iran, Islamic Republic of)

    2012-04-15

    Multiple sclerosis (MS) is an inflammatory demyelinating disease that the parts of the nervous system through the lesions generated in the white matter of the brain. It brings about disabilities in different organs of the body such as eyes and muscles. Early detection of MS and estimation of its progression are critical for optimal treatment of the disease. For diagnosis and treatment evaluation of MS lesions, they may be detected and segmented in Magnetic Resonance Imaging (MRI) scans of the brain. However, due to the large amount of MRI data to be analyzed, manual segmentation of the lesions by clinical experts translates into a very cumbersome and time consuming task. In addition, manual segmentation is subjective and prone to human errors. Several groups have developed computerized methods to detect and segment MS lesions. These methods are not categorized and compared in the past. This paper reviews and compares various MS lesion segmentation methods proposed in recent years. It covers conventional methods like multilevel thresholding and region growing, as well as more recent Bayesian methods that require parameter estimation algorithms. It also covers parameter estimation methods like expectation maximization and adaptive mixture model which are among unsupervised techniques as well as kNN and Parzen window methods that are among supervised techniques. Integration of knowledge-based methods such as atlas-based approaches with Bayesian methods increases segmentation accuracy. In addition, employing intelligent classifiers like Fuzzy C-Means, Fuzzy Inference Systems, and Artificial Neural Networks reduces misclassified voxels. (orig.)

  5. Lesion-based detection of early chemosensitivity using serial static FDG PET/CT in metastatic colorectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Buvat, Irene; Necib, Hatem [IMNC UMR 8165 CNRS - Paris 7 and Paris 11 Universities, Orsay cedex (France); Garcia, Camilo; Wagner, Antoine; Vanderlinden, Bruno; Flamen, Patrick [Universite Libre de Bruxelles, Nuclear Medicine Department, Institut Jules Bordet, Brussels (Belgium); Emonts, Patrick [Universite Libre de Bruxelles, Radiology Department, Institut Jules Bordet, Brussels (Belgium); Hendlisz, Alain [Universite Libre de Bruxelles, Digestive Oncology, Institut Jules Bordet, Brussels (Belgium)

    2012-10-15

    Medical oncology needs early identification of patients that are not responding to systemic therapy. {sup 18}F-Fluorodeoxyglucose (FDG) positron emission tomography (PET) performed before and early during treatment has been proposed for this purpose. However, the best way to assess the change in FDG uptake between two scans has not been identified. We studied cutoff thresholds to identify responding tumours as a function of the method used to measure tumour uptake. The study included 28 metastatic colorectal cancer (mCRC) patients who underwent 2 FDG PET/CT scans (baseline and at day 14 of the first course of polychemotherapy). For 78 tumour lesions, 4 standardized uptake value (SUV) indices were measured: maximum SUV (SUV{sub max}) and mean SUV in a region obtained using an isocontour (SUV{sub 40} {sub %}), with each of these SUV normalized either by the patient body weight (BW) or body surface area (BSA). The per cent change and absolute change in tumour uptake between the baseline and the early PET scans were measured based on these four indices. These changes were correlated to the RECIST 1.0-based response using contrast-enhanced CT at baseline and at 6-8 weeks on treatment. The 78 tumours were classified as non-responding (NRL, n = 58) and responding lesions (RL, n = 20). Receiver-operating characteristic (ROC) curves characterizing the performance in NRL/RL classification using early FDG PET uptake had areas under the curve between 0.75 and 0.84, without significant difference between the indices. The cutoff threshold in FDG uptake per cent change to get a 95 % sensitivity of RL detection depended on the way uptake was measured: -14 % (specificity of 53 %) and -22 % (specificity of 64 %) for SUV{sub max} and SUV{sub 40} {sub %}, respectively. Thresholds expressed as absolute SUV decrease instead of per cent change were less sensitive to the SUV definition: an SUV decline by 1.2 yielded a sensitivity of RL detection of 95 % for SUV{sub max} and SUV{sub 40

  6. Detection and Serogrouping of Dichelobacter nodosus Infection by Use of Direct PCR from Lesion Swabs To Support Outbreak-Specific Vaccination for Virulent Footrot in Sheep.

    Science.gov (United States)

    McPherson, Andrew S; Dhungyel, Om P; Whittington, Richard J

    2018-04-01

    Virulent footrot is an economically significant disease in most sheep-rearing countries. The disease can be controlled with vaccine targeting the fimbriae of virulent strains of the essential causative agent, Dichelobacter nodosus However, the bacterium is immunologically heterogeneous, and 10 distinct fimbrial serogroups have been identified. Ideally, in each outbreak the infecting strains would be cultured and serogrouped so that the appropriate serogroup-specific mono- or bivalent vaccine could be administered, because multivalent vaccines lack efficacy due to antigenic competition. If clinical disease expression is suspected to be incomplete, culture-based virulence tests are required to confirm the diagnosis, because control of benign footrot is economically unjustifiable. Both diagnosis and vaccination are conducted at the flock level. The aims of this study were to develop a PCR-based procedure for detecting and serogrouping D. nodosus directly from foot swabs and to determine whether this could be done accurately from the same cultured swab. A total of 269 swabs from the active margins of foot lesions of 261 sheep in 12 Merino sheep flocks in southeastern Australia were evaluated. DNA extracts taken from putative pure cultures of D. nodosus and directly from the swabs were evaluated in PCR assays for the 16S rRNA and fimA genes of D. nodosus Pure cultures were tested also by the slide agglutination test. Direct PCR using extracts from swabs was more sensitive than culture for detecting and serogrouping D. nodosus strains. Using the most sensitive sample collection method of the use of swabs in lysis buffer, D. nodosus was more likely to be detected by PCR in active than in inactive lesions, and in lesions with low levels of fecal contamination, but lesion score was not a significant factor. PCR conducted on extracts from swabs in modified Stuart's transport medium that had already been used to inoculate culture plates had lower sensitivity. Therefore, if

  7. Human papilloma virus 18 detection in oral squamous cell carcinoma and potentially malignant lesions using saliva samples.

    Science.gov (United States)

    Goot-Heah, Khor; Kwai-Lin, Thong; Froemming, Gabriele Ruth Anisah; Abraham, Mannil Thomas; Nik Mohd Rosdy, Nik Mohd Mazuan; Zain, Rosnah Binti

    2012-01-01

    Oral cancer has become one of the most prevalent cancers worldwide and human Papillomavirus is one of the risk factors for developing oral cancer. For this study HPV18 was chosen as it is one of the high risk HPV types and may lead to carcinogenesis. However, prevalence of HPV18 infection in Oral Squamous Cell Carcinoma in Malaysia remains unclear. This study aimed to investigate the viral load of HPV18 DNA in OSCC and potentially malignant lesions using saliva samples. Genomic DNAs of thirty saliva samples of normal subjects and thirty saliva samples compromised of 16 samples from potentially malignant lesions and 14 of OSCC patients were amplified for HPV18 DNA using a nested polymerase chain reaction analysis. All PCR products were then analyzed using the Bioanalyzer to confirm presence of HPV18 DNA. From thirty patients examined, only one of 30 (3.3%) cases was found to be positive for HPV18 in this study. The finding of this study revealed that there is a low viral detection of HPV18 in Malaysian OSCC by using saliva samples, suggesting that prevalence of HPV18 may not be important in this group of Malaysian OSCC.

  8. Tissue resonance interaction accurately detects colon lesions: A double-blind pilot study.

    Science.gov (United States)

    Dore, Maria P; Tufano, Marcello O; Pes, Giovanni M; Cuccu, Marianna; Farina, Valentina; Manca, Alessandra; Graham, David Y

    2015-07-07

    To investigated the performance of the tissue resonance interaction method (TRIM) for the non-invasive detection of colon lesions. We performed a prospective single-center blinded pilot study of consecutive adults undergoing colonoscopy at the University Hospital in Sassari, Italy. Before patients underwent colonoscopy, they were examined by the TRIMprobe which detects differences in electromagnetic properties between pathological and normal tissues. All patients had completed the polyethylene glycol-containing bowel prep for the colonoscopy procedure before being screened. During the procedure the subjects remained fully dressed. A hand-held probe was moved over the abdomen and variations in electromagnetic signals were recorded for 3 spectral lines (462-465 MHz, 930 MHz, and 1395 MHz). A single investigator, blind to any clinical information, performed the test using the TRIMprob system. Abnormal signals were identified and recorded as malignant or benign (adenoma or hyperplastic polyps). Findings were compared with those from colonoscopy with histologic confirmation. Statistical analysis was performed by χ(2) test. A total of 305 consecutive patients fulfilling the inclusion criteria were enrolled over a period of 12 months. The most frequent indication for colonoscopy was abdominal pain (33%). The TRIMprob was well accepted by all patients; none spontaneously complained about the procedure, and no adverse effects were observed. TRIM proved inaccurate for polyp detection in patients with inflammatory bowel disease (IBD) and they were excluded leaving 281 subjects (mean age 59 ± 13 years; 107 males). The TRIM detected and accurately characterized all 12 adenocarcinomas and 135/137 polyps (98.5%) including 64 adenomatous (100%) found. The method identified cancers and polyps with 98.7% sensitivity, 96.2% specificity, and 97.5% diagnostic accuracy, compared to colonoscopy and histology analyses. The positive predictive value was 96.7% and the negative predictive

  9. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    Energy Technology Data Exchange (ETDEWEB)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G. [University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C. [University Dusseldorf, Medical Faculty, Department of Urology, Dusseldorf (Germany); Gabbert, H.E. [University Dusseldorf, Medical Faculty, Department of Pathology, Dusseldorf (Germany)

    2016-11-15

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  10. Targeted MRI-guided prostate biopsy: are two biopsy cores per MRI-lesion required?

    International Nuclear Information System (INIS)

    Schimmoeller, L.; Quentin, M.; Blondin, D.; Dietzel, F.; Schleich, C.; Thomas, C.; Antoch, G.; Hiester, A.; Rabenalt, R.; Albers, P.; Arsov, C.; Gabbert, H.E.

    2016-01-01

    This study evaluates the feasibility of performing less than two core biopsies per MRI-lesion when performing targeted MR-guided in-bore prostate biopsy. Retrospectively evaluated were 1545 biopsy cores of 774 intraprostatic lesions (two cores per lesion) in 290 patients (66 ± 7.8 years; median PSA 8.2 ng/ml) regarding prostate cancer (PCa) detection, Gleason score, and tumor infiltration of the first (FBC) compared to the second biopsy core (SBC). Biopsies were acquired under in-bore MR-guidance. For the biopsy cores, 491 were PCa positive, 239 of 774 (31 %) were FBC and 252 of 771 (33 %) were SBC (p = 0.4). Patient PCa detection rate based on the FBC vs. SBC were 46 % vs. 48 % (p = 0.6). For clinically significant PCa (Gleason score ≥4 + 3 = 7) the detection rate was 18 % for both, FBC and SBC (p = 0.9). Six hundred and eighty-seven SBC (89 %) showed no histologic difference. On the lesion level, 40 SBC detected PCa with negative FBC (7.5 %). Twenty SBC showed a Gleason upgrade from 3 + 3 = 6 to ≥3 + 4 = 7 (2.6 %) and 4 to ≥4 + 3 = 7 (0.5 %). The benefit of a second targeted biopsy core per suspicious MRI-lesion is likely minor, especially regarding PCa detection rate and significant Gleason upgrading. Therefore, a further reduction of biopsy cores is reasonable when performing a targeted MR-guided in-bore prostate biopsy. (orig.)

  11. Stereotaxic Fine-Needle Aspiration Cytologic Evaluation of Non-palpable Breast Lesions

    Directory of Open Access Journals (Sweden)

    M Haghighi

    2005-07-01

    Full Text Available Background: Although long-term mammography is the standard means of evaluation for the probably benign lesions of breast, some times we feel obliged to know about the benignity and the extent of lesions earlier. Therefore we evaluated the diagnostic value of stereotaxic fine-needle aspiration (SFNA in low suspicion breast lesions as an alternative to the routine modality. Methods: The study included 150 low-suspicion or probably benign breast lesions detected on mammography. All cases underwent SFNA and followed by exciosional biopsy or follow-up mammography based on SFNA findings. Results: Fibroadenoma and normal tissue lesions were diagnosed in 57% of patients, in whom no evidence of malignancy was found in the follow-up period. In 48 patients with cytologic findings suggestive of proliferative fibrocystic disease, three cases of malignancy were detected by excisional biopsy. Conclusion: A SFNA result suggesting benignity allows safe clinical follow-up, whereas a suspicious or equivocal diagnosis needs more invasive modalities for further investigations. Key words: Breast, Mammography, Stereotaxic, Fine-Needle Aspiration (FNA

  12. RESOLVED COMPANIONS OF CEPHEIDS: TESTING THE CANDIDATES WITH X-RAY OBSERVATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Evans, Nancy Remage; Pillitteri, Ignazio; Wolk, Scott; Karovska, Margarita; Tingle, Evan [Smithsonian Astrophysical Observatory, MS 4, 60 Garden St., Cambridge, MA 02138 (United States); Guinan, Edward; Engle, Scott [Department of Astronomy and Astrophysics, Villanova University, 800 Lancaster Ave., Villanova, PA 19085 (United States); Bond, Howard E. [Department of Astronomy and Astrophysics, Pennsylvania State University, University Park, PA 16802 (United States); Schaefer, Gail H. [The CHARA Array of Georgia State University, Mount Wilson, California 91023 (United States); Mason, Brian D., E-mail: nevans@cfa.harvard.edu, E-mail: heb11@psu.edu, E-mail: schaefer@chara-array.org [US Naval Observatory, 3450 Massachusetts Ave., NW, Washington, DC 20392-5420 (United States)

    2016-04-15

    We have made XMM-Newton observations of 14 Galactic Cepheids that have candidate resolved (≥5″) companion stars based on our earlier HST Wide Field Camera 3 (WFC3) imaging survey. Main-sequence stars that are young enough to be physical companions of Cepheids are expected to be strong X-ray producers in contrast to field stars. XMM-Newton exposures were set to detect essentially all companions hotter than spectral type M0 (corresponding to 0.5 M{sub ⊙}). The large majority of our candidate companions were not detected in X-rays, and hence are not confirmed as young companions. One resolved candidate (S Nor #4) was unambiguously detected, but the Cepheid is a member of a populous cluster. For this reason, it is likely that S Nor #4 is a cluster member rather than a gravitationally bound companion. Two further Cepheids (S Mus and R Cru) have X-ray emission that might be produced by either the Cepheid or the candidate resolved companion. A subsequent Chandra observation of S Mus shows that the X-rays are at the location of the Cepheid/spectroscopic binary. R Cru and also V659 Cen (also X-ray bright) have possible companions closer than 5″ (the limit for this study) which are the likely sources of X-rays. One final X-ray detection (V473 Lyr) has no known optical companion, so the prime suspect is the Cepheid itself. It is a unique Cepheid with a variable amplitude. The 14 stars that we observed with XMM constitute 36% of the 39 Cepheids found to have candidate companions in our HST/WFC3 optical survey. No young probable binary companions were found with separations of ≥5″ or 4000 au.

  13. RESOLVED COMPANIONS OF CEPHEIDS: TESTING THE CANDIDATES WITH X-RAY OBSERVATIONS

    International Nuclear Information System (INIS)

    Evans, Nancy Remage; Pillitteri, Ignazio; Wolk, Scott; Karovska, Margarita; Tingle, Evan; Guinan, Edward; Engle, Scott; Bond, Howard E.; Schaefer, Gail H.; Mason, Brian D.

    2016-01-01

    We have made XMM-Newton observations of 14 Galactic Cepheids that have candidate resolved (≥5″) companion stars based on our earlier HST Wide Field Camera 3 (WFC3) imaging survey. Main-sequence stars that are young enough to be physical companions of Cepheids are expected to be strong X-ray producers in contrast to field stars. XMM-Newton exposures were set to detect essentially all companions hotter than spectral type M0 (corresponding to 0.5 M ⊙ ). The large majority of our candidate companions were not detected in X-rays, and hence are not confirmed as young companions. One resolved candidate (S Nor #4) was unambiguously detected, but the Cepheid is a member of a populous cluster. For this reason, it is likely that S Nor #4 is a cluster member rather than a gravitationally bound companion. Two further Cepheids (S Mus and R Cru) have X-ray emission that might be produced by either the Cepheid or the candidate resolved companion. A subsequent Chandra observation of S Mus shows that the X-rays are at the location of the Cepheid/spectroscopic binary. R Cru and also V659 Cen (also X-ray bright) have possible companions closer than 5″ (the limit for this study) which are the likely sources of X-rays. One final X-ray detection (V473 Lyr) has no known optical companion, so the prime suspect is the Cepheid itself. It is a unique Cepheid with a variable amplitude. The 14 stars that we observed with XMM constitute 36% of the 39 Cepheids found to have candidate companions in our HST/WFC3 optical survey. No young probable binary companions were found with separations of ≥5″ or 4000 au

  14. Alienness: Rapid Detection of Candidate Horizontal Gene Transfers across the Tree of Life

    Directory of Open Access Journals (Sweden)

    Corinne Rancurel

    2017-09-01

    Full Text Available Horizontal gene transfer (HGT is the transmission of genes between organisms by other means than parental to offspring inheritance. While it is prevalent in prokaryotes, HGT is less frequent in eukaryotes and particularly in Metazoa. Here, we propose Alienness, a taxonomy-aware web application available at http://alienness.sophia.inra.fr. Alienness parses BLAST results against public libraries to rapidly identify candidate HGT in any genome of interest. Alienness takes as input the result of a BLAST of a whole proteome of interest against any National Center for Biotechnology Information (NCBI protein library. The user defines recipient (e.g., Metazoa and donor (e.g., bacteria, fungi branches of interest in the NCBI taxonomy. Based on the best BLAST E-values of candidate donor and recipient taxa, Alienness calculates an Alien Index (AI for each query protein. An AI > 0 indicates a better hit to candidate donor than recipient taxa and a possible HGT. Higher AI represent higher gap of E-values between candidate donor and recipient and a more likely HGT. We confirmed the accuracy of Alienness on phylogenetically confirmed HGT of non-metazoan origin in plant-parasitic nematodes. Alienness scans whole proteomes to rapidly identify possible HGT in any species of interest and thus fosters exploration of HGT more easily and largely across the tree of life.

  15. Imaging techniques in the study of lipomatous neck lesions

    International Nuclear Information System (INIS)

    Munoz, M. M.; Herrero, C.; Garcia, M. J.; Sanchez-Lafuente, J.

    2001-01-01

    Lipomas of the neck are uncommon lesions. Those situated in deep locations and diffuse lipomatosis of the neck can be clinically mis diagnosed. We reviewed the 20 lipomatous neck lesions treated in our hospital over a 15-year period (1985-1999). Computed tomography was diagnostic in nearly 100% of cases and, this, is the method of choice for the detection and characterization of lipomatous tumors. It also provides data that aid in planning the surgical approach and enables the follow-up of clinically stable lesions that do not require surgical treatment. (Author) 11 refs

  16. Diagnostic value of whole-body low-dose computed tomography (WBLDCT) in bone lesions detection in patients with multiple myeloma (MM)

    Energy Technology Data Exchange (ETDEWEB)

    Ippolito, Davide, E-mail: davide.atena@tiscalinet.it [School of Medicine, University of Milano-Bicocca, Via Pergolesi 33, 20900 Monza (MB) (Italy); Department of Diagnostic Radiology, H. San Gerardo, Via Pergolesi 33, 20900 Monza (MB) (Italy); Besostri, Valeria, E-mail: valeriabesostri@gmail.com [School of Medicine, University of Milano-Bicocca, Via Pergolesi 33, 20900 Monza (MB) (Italy); Department of Diagnostic Radiology, H. San Gerardo, Via Pergolesi 33, 20900 Monza (MB) (Italy); Bonaffini, Pietro Andrea, E-mail: pa.bonaffini@gmail.com [School of Medicine, University of Milano-Bicocca, Via Pergolesi 33, 20900 Monza (MB) (Italy); Department of Diagnostic Radiology, H. San Gerardo, Via Pergolesi 33, 20900 Monza (MB) (Italy); Rossini, Fausto, E-mail: valeriabesostri@hotmail.it [Department of Hematology, H. San Gerardo, Via Pergolesi 33, 20900 Monza (MB) (Italy); Di Lelio, Alessandro, E-mail: valebeso@libero.it [Department of Diagnostic Radiology, H. San Gerardo, Via Pergolesi 33, 20900 Monza (MB) (Italy); Sironi, Sandro, E-mail: sandrosironi@libero.it [School of Medicine, University of Milano-Bicocca, Via Pergolesi 33, 20900 Monza (MB) (Italy); Department of Diagnostic Radiology, H. San Gerardo, Via Pergolesi 33, 20900 Monza (MB) (Italy)

    2013-12-01

    Purpose: To assess the role of whole-body low-dose computed tomography (WBLDCT) in the diagnosis and staging of patients with suspicion of multiple myeloma (MM). Materials and methods: A total of 138 patients (76 male and 62 female; mean age 63.5 years, range 50–81 years), with early MM, underwent WBLDCT protocol study, performed on 16-slice scanner (Brilliance, Philips Medical System, Eindhoven, The Netherlands): tube voltage 120 kV; tube current time product 40 mAs. Diagnosis of osteolytic lesions was performed on the basis of axial and multiplanar reformatted images, whereas the assessment of spinal misalignment and fracture was done by using multiplanar reformatted images. The overall dose delivered to each patient was 4.2 mSv. Every patient gave personal informed consent, as required by our institution guidelines. Results: The diagnosis was established either by histopathology or imaging follow-up (size increase of over a period time). In all 138 patients, image resolution was diagnostic, enabling correct classification of multiple myeloma patients. WBLDCT showed a total of 328 pathologic bone findings in 81/138 patients. CT scanning resulted in complete evaluation of the bone lesions in these areas of the skeleton: skull (42), humerus (15), femur (20), ribs (7), scapulae (13), pelvis (35), clavicle (13), sternum (10), cervical (39), dorsal (65), lombar (48) and sacral rachis (21). In 40/81 bone involvement detected by CT was the only CRAB criterion present. Furthermore, WBLDCT demonstrated pleuro-pulmonary lesions in 20 patients (11 infective, 9 as MM localizations) and 1 renal neoplasia. Conclusion: WBLDCT, detecting bone marrow localizations and demonstrating extra-osseous findings, with a fast scanning time and high resolution images, is a reliable imaging-based tool for a proper management of MM patients.

  17. Sonography and computed tomography of splenic nonsystemic lesions

    International Nuclear Information System (INIS)

    Garretti, L.; Cassinis, M.C.; Gandini, G.

    1987-01-01

    Differential diagnosis problems are caused by the increased, at time occasional detection of benignant and malignant spleen focal lesions in routine superior abdomen ultrasound (US). The following pathologic conditions were reported in 29 patients with focal lesions (excepted systemic diseases): 6 plain cysts, 1 cystic lymphangioma, 3 echinococcus cysts, 3 abscesses, 7 hematomas and 9 metastases. US examination and clinical data together have permitted the differentiation of cysts from solid nodules but has limits in the characterzation of lesions and in the diagnosis of abscesses. Metastases did non present specific US or CT aspects and have been correctly charaterized only with aid of anamnestical data and for the coexhistence of hepatic lesions. CT has proven superior specificity, compared to US, only in the diagnosis of abscesses and should thus be utilized only in selected cases

  18. Detection of Treponema pallidum subsp. pallidum from Skin Lesions, Serum, and Cerebrospinal Fluid in an Infant with Congenital Syphilis after Clindamycin Treatment of the Mother during Pregnancy▿

    Science.gov (United States)

    Woznicová, Vladana; Šmajs, David; Wechsler, Dan; Matějková, Petra; Flasarová, Magdalena

    2007-01-01

    We report here a case of congenital syphilis in a newborn after clindamycin treatment in pregnancy. Using PCR detection of tmpC (TP0319) and DNA sequencing of the genes TP0136 and TP0548, DNA sequences identical to Treponema pallidum subsp. pallidum strain SS14 were detected in the infant's skin lesions, serum, and cerebrospinal fluid. PMID:17151205

  19. Optoacoustic detection of thermal lesions

    Science.gov (United States)

    Arsenault, Michel G.; Kolios, Michael C.; Whelan, William M.

    2009-02-01

    Minimally invasive thermal therapy is being investigated as an alternative cancer treatment. It involves heating tissues to greater than 55°C over a period of a few minutes, which results in tissue coagulation. Optoacoustic (OA) imaging is a new imaging technique that involves exposing tissues to pulsed light and detecting the acoustic waves that are generated. In this study, adult bovine liver tissue samples were heated using continuous wave laser energy for various times, then scanned using an optoacoustic imaging system. Large optoacoustic signal variability was observed in the native tissue prior to heating. OA signal amplitude increased with maximum tissue temperature achieved, characterized by a correlation coefficient of 0.63. In this study we show that there are detectable changes in optoacoustic signal strength that arise from tissue coagulation, which demonstrates the potential of optoacoustic technology for the monitoring of thermal therapy delivery.

  20. 99m Tc-MIP-1404-SPECT/CT for the detection of PSMA-positive lesions in 225 patients with biochemical recurrence of prostate cancer.

    Science.gov (United States)

    Schmidkonz, Christian; Hollweg, Claudia; Beck, Michael; Reinfelder, Julia; Goetz, Theresa I; Sanders, James C; Schmidt, Daniela; Prante, Olaf; Bäuerle, Tobias; Cavallaro, Alexander; Uder, Michael; Wullich, Bernd; Goebell, Peter; Kuwert, Torsten; Ritt, Philipp

    2018-01-01

    99m Tc-MIP-1404 (Progenics Pharmaceuticals, Inc., New York, NY) is a novel, SPECT-compatible 99m Tc-labeled PSMA inhibitor for the detection of prostate cancer. We present results of its clinical use in a cohort of 225 men with histologically confirmed prostate cancer referred for workup of biochemical relapse. From April 2013 to April 2017, 99m Tc-MIP1404-scintigraphy was performed in 225 patients for workup of PSA biochemical relapse of prostate cancer. Whole-body planar and SPECT/CT images of the lower abdomen and thorax were obtained 3-4 h p.i. of 710 ± 64 MBq 99m Tc-MIP-1404. Images were visually analyzed for presence and location of abnormal uptake. In addition, quantitative analysis of the SPECT/CT data was carried out on a subset of 125 patients. Follow-up reports of subsequent therapeutic interventions were available for 59% (139) of all patients. Tracer-positive lesions were detected in 77% (174/225) of all patients. Detections occurred at the area of local recurrence in the prostate in 25% of patients (or a total of 56), with metastases in lymph nodes in 47% (105), bone in 27% (60), lung in 5% (12), and other locations in 2% (4) of patients. Detection rates were 90% at PSA levels ≥2 ng/mL and 54% below that threshold. Lesional SUVmax values were, on average, 32.2 ± 29.6 (0.8-142.2), and tumor-to-normal ratios 146.6 ± 160.5 (1.9-1482.4). The PSA level correlated significantly with total uptake of MIP-1404 in tumors (P Tc-MIP-1404-imaging and other information, an interdisciplinary tumor board review recommended changes to treatment plans in 74% (104/139) of those patients for whom the necessary documentation was available. SPECT/CT with 99m Tc-labeled MIP-1404 has a high probability in detecting PSMA-positive lesions in patients with elevated PSA. Statistical analysis disclosed significant relationship between quantitative 99m Tc-MIP-1404 uptake, PSA level, and Gleason score. © 2017 Wiley Periodicals, Inc.

  1. Localization of occult breast lesions: mammographic findings in non infiltrating carcinoma; Localizacion de lesiones ocultas de mama: hallazgos mamograficos del carcinoma no infiltrante

    Energy Technology Data Exchange (ETDEWEB)

    Paul, L; Iribar, M; Vilarrasa, A; Lopez, M A; Hernandez, R; Carrasco, A [Departamento de Radiodiagnostico, Hospital Doce de Octubre, Madrid (Spain)

    1995-08-01

    A review was carried out of 169 biopsies of occult breast lesions, 32 of which were malignant. The radiological findings associated with in situ carcinomas were compared with those of malignant lesions in general. The signs that permit the detection of breast carcinoma in the earliest stages are described, and the positive predictive value of signs, such as a spicular form, clusters of microcalcifications, nodules and architectural disturbances, is discussed. Given the lack of specificity of these findings, many beginning lesions should be biopsied to ensure an early diagnosis of breast cancer. (Author)

  2. Early dynamic 18F-FDG PET to detect hyperperfusion in hepatocellular carcinoma liver lesions.

    Science.gov (United States)

    Schierz, Jan-Henning; Opfermann, Thomas; Steenbeck, Jörg; Lopatta, Eric; Settmacher, Utz; Stallmach, Andreas; Marlowe, Robert J; Freesmeyer, Martin

    2013-06-01

    In addition to angiographic data on vascularity and vascular access, demonstration of hepatocellular carcinoma (HCC) liver nodule hypervascularization is a prerequisite for certain intrahepatic antitumor therapies. Early dynamic (ED) (18)F-FDG PET/CT could serve this purpose when the current standard method, contrast-enhanced (CE) CT, or other CE morphologic imaging modalities are unsuitable. A recent study showed ED (18)F-FDG PET/CT efficacy in this setting but applied a larger-than-standard (18)F-FDG activity and an elaborate protocol likely to hinder routine use. We developed a simplified protocol using standard activities and easily generated visual and descriptive or quantitative endpoints. This pilot study assessed the ability of these endpoints to detect HCC hyperperfusion and, thereby, evaluated the suitability in of the protocol everyday practice. Twenty-seven patients with 34 HCCs (diameter ≥ 1.5 cm) with hypervascularization on 3-phase CE CT underwent liver ED (18)F-FDG PET for 240 s, starting with (18)F-FDG (250-MBq bolus injection). Four frames at 15-s intervals, followed by 3 frames at 60-s intervals were reconstructed. Endpoints included focal tracer accumulation in the first 4 frames (60 s), subsequent focal washout, and visual and quantitative differences between tumor and liver regions of interest in maximum and mean ED standardized uptake value (ED SUVmax and ED SUVmean, respectively) 240-s time-activity curves. All 34 lesions were identified by early focal (18)F-FDG accumulation and faster time-to-peak ED SUVmax or ED SUVmean than in nontumor tissue. Tumor peak ED SUVmax and ED SUVmean exceeded liver levels in 85% and 53%, respectively, of lesions. Nadir tumor signal showed no consistent pattern relative to nontumor signal. HCC had a significantly shorter time to peak and significantly faster rate to peak for both ED SUVmax and ED SUVmean curves and a significantly higher peak ED SUVmax but not peak ED SUVmean than the liver. This pilot study

  3. Progress risk assessment of oral premalignant lesions with saliva miRNA analysis

    International Nuclear Information System (INIS)

    Yang, Ya; Li, Yue-xiu; Yang, Xi; Jiang, Long; Zhou, Zuo-jun; Zhu, Ya-qin

    2013-01-01

    Oral cancer develops through multi-stages: from normal to mild (low grade) dysplasia (LGD), moderate dysplasia, and severe (high grade) dysplasia (HGD), to carcinoma in situ (CIS) and finally invasive oral squamous cell carcinomas (OSCC). Clinical and histological assessments are not reliable in predicting which precursor lesions will progress. The aim of this study was to assess the potential of a noninvasive approach to assess progress risk of oral precancerous lesions. We first used microRNA microarray to profile progressing LGD oral premaligant lesions (OPLs) from non-progressing LGD OPLs in order to explore the possible microRNAs deregulated in low grade OPLs which later progressed to HGD or OSCC. We then used RT-qPCR to detect miRNA targets from the microarray results in saliva samples of these patients. We identified a specific miRNA signature that is aberrantly expressed in progressing oral LGD leukoplakias. Similar expression patterns were detected in saliva samples from these patients. These results show promise for using saliva miRNA signature for monitoring of cancer precursor lesions and early detection of disease progression

  4. Bone lesions in Chinese POEMS syndrome patients: imaging characteristics and clinical implications.

    Science.gov (United States)

    Wang, Fengdan; Huang, Xufei; Zhang, Yan; Li, Jian; Zhou, Daobin; Jin, Zhengyu

    2016-01-01

    Objective. Bone lesion is crucial for diagnosing and management of polyneuropathy, organomegaly, endocrinopathy, monoclonal protein, and skin change (POEMS) syndrome, a rare plasma cell disorder. This study is to compare the effectiveness of X-ray skeletal survey (SS) and computed tomography (CT) for detecting bone lesions in Chinese POEMS syndrome patients, and to investigate the relationship between bone lesion features and serum markers. Methods. SS and chest/abdomen/pelvic CT images of 38 Chinese patients (26 males, 12 females, aged 21-70 years) with POEMS syndrome recruited at our medical center between January 2013 and January 2015 were retrospectively analyzed. Bone lesions identified by CT were further categorized according to the size (10 mm) and appearance (osteosclerotic, lytic, mixed). The percentage of plasma cells in bone marrow smears, type of immunoglobulin, platelet (Plt), and levels of serum bone metabolic markers and inflammatory factors including alkaline phosphatase (ALP), calcium, phosphate, parathyroid hormone (PTH), beta-isomerized C-telopeptide (β-CTx), vascular endothelial growth factor (VEGF), and interleukin (IL)-6 levels were also recorded. Results. Of the 38 POEMS syndrome patients, the immunoglobulin heavy chain isotypes were IgA in 25 patients (65.8%; 25/38) and IgG in 13 patients (34.2%; 13/38), and the light chain isotypes were λ in 35 patients (92.1%; 35/38) and κ in 3 patients (7.9%; 3/38). There were 23 patients with thrombocytosis. More patients with bone lesions were detected by CT than by SS (97.4% vs. 86.8%). The most commonly affected location was the pelvis (89.5%), followed by the spine, clavicle/scapula/sternum/ribs, skull, and long bones. Of the 38 POEMS syndrome patients, 35 (94.6%) had osteosclerotic and 32 (86.5%) had mixed lesions. Osteosclerotic lesions were typically scattered, variable in size, and plaque-like, whereas mixed lesions were pouch-shaped or soup bubble-like with a clear sclerotic margin and were

  5. Significance of localization of nonpalpable breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Ki Keun; Choi, Hyun Ju [Yongdong Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1990-12-15

    As mammography has become more popular for the evaluation of breast symptoms and for the screening of asymptomatic women, the smaller lesions are being detected before they become palpable, therefore preoperative localization became necessary. This has led to the development of several methods for preoperative localization of nonpalpable lesions. Authors analyzed 50 cases with preoperative localization in 45 patients which had abnormal findings on film mammogram or ultrasonomammogram since October 1985 through March 1990 at Yongdong Severance Hospital, College of Medicine, Yonsei University. The results were as follows: 1. Techniques of localization were spot method in 8 cases, conventional needle localization method in 38 cases and Kopan's needle localization method in 4 cases. 2. The most common mammographic indication for localization was focal calcifications in 29 cases(58%), which was followed by a newly developed mass in 25 cases(50%). 3. Outcome of pathologically confirmed diagnosis put into benign lesions in 37 cases(74%) and malignant lesions in 13 cases(26%). 4. Among the cases with localization of lesions which has suggested as benign lesions in film and ultrasonomammogram,all cases(100%) were confirmed in benign lesions pathologically. Among the cases with localization of lesions which has suggested as malignant lesions in film and ultrasonomammogram, pathologic malignant has been proved of 44% and possible histopathologic precursor of malignant was resulted in 25% such as atypical hyperplasia and adenosis. Conclusively, authors consider that the abnormal areas should be removed in their entirety with the sacrifice of minimum volume of contiguous normal breast tissue through the preoperative localization, hence our preoperative localization has contributed favorable prognosis based on material lesions in early stage breast cancer.

  6. Significance of localization of nonpalpable breast lesions

    International Nuclear Information System (INIS)

    Oh, Ki Keun; Choi, Hyun Ju

    1990-01-01

    As mammography has become more popular for the evaluation of breast symptoms and for the screening of asymptomatic women, the smaller lesions are being detected before they become palpable, therefore preoperative localization became necessary. This has led to the development of several methods for preoperative localization of nonpalpable lesions. Authors analyzed 50 cases with preoperative localization in 45 patients which had abnormal findings on film mammogram or ultrasonomammogram since October 1985 through March 1990 at Yongdong Severance Hospital, College of Medicine, Yonsei University. The results were as follows: 1. Techniques of localization were spot method in 8 cases, conventional needle localization method in 38 cases and Kopan's needle localization method in 4 cases. 2. The most common mammographic indication for localization was focal calcifications in 29 cases(58%), which was followed by a newly developed mass in 25 cases(50%). 3. Outcome of pathologically confirmed diagnosis put into benign lesions in 37 cases(74%) and malignant lesions in 13 cases(26%). 4. Among the cases with localization of lesions which has suggested as benign lesions in film and ultrasonomammogram,all cases(100%) were confirmed in benign lesions pathologically. Among the cases with localization of lesions which has suggested as malignant lesions in film and ultrasonomammogram, pathologic malignant has been proved of 44% and possible histopathologic precursor of malignant was resulted in 25% such as atypical hyperplasia and adenosis. Conclusively, authors consider that the abnormal areas should be removed in their entirety with the sacrifice of minimum volume of contiguous normal breast tissue through the preoperative localization, hence our preoperative localization has contributed favorable prognosis based on material lesions in early stage breast cancer

  7. Combination of one-view digital breast tomosynthesis with one-view digital mammography versus standard two-view digital mammography: per lesion analysis

    Energy Technology Data Exchange (ETDEWEB)

    Gennaro, Gisella; Bezzon, Elisabetta; Pescarini, Luigi; Polico, Ilaria; Proietti, Alessandro; Baldan, Enrica; Pomerri, Fabio; Muzzio, Pier Carlo [Veneto Institute of Oncology (IRCCS), Padua (Italy); Hendrick, R.E. [University of Colorado-Denver, Department of Radiology, School of Medicine, Aurora, CO (United States); Toledano, Alicia [Biostatistics Consulting, LLC, Kensington, MD (United States); Paquelet, Jean R. [Advanced Medical Imaging Consultants, Fort Collins, CO (United States); Breast Imaging, McKee Medical Center, Loveland, CO (United States); Chersevani, Roberta [Private Medical Practice, Gorizia (Italy); Di Maggio, Cosimo [Private Medical Practice, Padua (Italy); La Grassa, Manuela [Department of Radiology, Oncological Reference Center (IRCCS), Aviano (Italy)

    2013-08-15

    To evaluate the clinical value of combining one-view mammography (cranio-caudal, CC) with the complementary view tomosynthesis (mediolateral-oblique, MLO) in comparison to standard two-view mammography (MX) in terms of both lesion detection and characterization. A free-response receiver operating characteristic (FROC) experiment was conducted independently by six breast radiologists, obtaining data from 463 breasts of 250 patients. Differences in mean lesion detection fraction (LDF) and mean lesion characterization fraction (LCF) were analysed by analysis of variance (ANOVA) to compare clinical performance of the combination of techniques to standard two-view digital mammography. The 463 cases (breasts) reviewed included 258 with one to three lesions each, and 205 with no lesions. The 258 cases with lesions included 77 cancers in 68 breasts and 271 benign lesions to give a total of 348 proven lesions. The combination, DBT{sub (MLO)}+MX{sub (CC)}, was superior to MX (CC+MLO) in both lesion detection (LDF) and lesion characterization (LCF) overall and for benign lesions. DBT{sub (MLO)}+MX{sub (CC)} was non-inferior to two-view MX for malignant lesions. This study shows that readers' capabilities in detecting and characterizing breast lesions are improved by combining single-view digital breast tomosynthesis and single-view mammography compared to two-view digital mammography. (orig.)

  8. Diffusion weighted imaging of liver lesions suspect for metastases: Apparent diffusion coefficient (ADC) values and lesion contrast are independent from Gd-EOB-DTPA administration

    International Nuclear Information System (INIS)

    Benndorf, Matthias; Schelhorn, Juliane; Dietzel, Matthias; Kaiser, Werner A.; Baltzer, Pascal A.T.

    2012-01-01

    Purpose: Gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA) enhanced liver MRI is widely used for detection and differentiation of focal liver lesions. Diffusion weighted imaging (DWI) including apparent diffusion coefficient (ADC) measurements is increasingly utilised as a fast and, with limitations, quantitative method for liver lesion detection and characterisation. Herein we investigate whether the administration of Gd-EOB-DTPA affects DWI. Materials and methods: 31 consecutive patients referred to standardised liver MRI (1.5 T, Gd-EOB-DTPA, 0.025 mmol/kg) were retrospectively reviewed. All underwent a breathhold DWI sequence before and after contrast agent administration (EPI-DWI, TR/TE (effective): 2100/62 ms, b-values: 0 and 800 s/mm 2 ). Patients with previously treated liver lesions were excluded. Signal intensity of lesion, parenchyma and noise on DWI images as well as the ADC value were measured after identification by two observers in consensus using manually placed regions of interest. The reference standard was imaging follow-up determined separately by two radiologists. Data analysis included signal-to-noise (SNR) ratio and contrast-to-noise ratio (CNR) calculations, comparisons were drawn by employing multiple Bonferroni corrected Wilcoxon signed-rank tests. Results: 50 malignant and 39 benign lesions were identified. Neither SNR, CNR nor ADC values showed significant differences between pre- and postcontrast DWI. Both pre- and postcontrast ADC values differed significantly between benign and malignant lesions (P < 0.001). Conclusion: We did not identify a significant influence of Gd-EOB-DTPA on DWI of liver lesions. This allows for individual tailoring of imaging protocols according to clinical needs.

  9. Independent histogram pursuit for segmentation of skin lesions

    DEFF Research Database (Denmark)

    Gomez, D.D.; Butakoff, C.; Ersbøll, Bjarne Kjær

    2008-01-01

    In this paper, an unsupervised algorithm, called the Independent Histogram Pursuit (HIP), for segmenting dermatological lesions is proposed. The algorithm estimates a set of linear combinations of image bands that enhance different structures embedded in the image. In particular, the first estima...... to deal with different types of dermatological lesions. The boundary detection precision using k-means segmentation was close to 97%. The proposed algorithm can be easily combined with the majority of classification algorithms....

  10. The accuracy of chest radiographs in the detection of congenital heart disease and in the diagnosis of specific congenital cardiac lesions

    International Nuclear Information System (INIS)

    Laya, Bernard F.; Goske, Marilyn J.; Morrison, Stuart; Reid, Janet R.; Swischuck, Leonard; Ey, Elizabeth H.; Murphy, Daniel J.; Lieber, Michael; Obuchowski, Nancy

    2006-01-01

    Congenital heart disease (CHD) is a significant cause of morbidity and mortality in pediatric patients. Traditional teaching holds that specific types of CHD can be diagnosed on the chest radiograph (CXR) through pattern recognition. To determine the accuracy of radiologists in detecting CHD on the CXR. This study was a blinded retrospective review of chest radiographs from 281 patients (<12 years) by five pediatric radiologists from three institutions. Thirteen groups were evaluated that included 12 categories of CHD and a control group of patients without heart disease. Radiographs were assessed for heart size, heart and mediastinal shape and vascularity. Clinical information, angiography, echocardiograms and surgery were used as the gold standard for definitive diagnosis. The average accuracy of the five readers in distinguishing normal from CHD patients was 78% (range of 72% to 82%). The overall measure of accuracy in distinguishing specific congenital cardiac lesions among 13 groups of patients was 71% (range of 63% to 79%). CXR alone is not diagnostic of specific cardiac lesions, with a low accuracy of only 71%. We believe that less emphasis should be placed on the use of radiographs alone in diagnosing specific congenital cardiac lesions. (orig.)

  11. Performance of human observers and an automatic 3-dimensional computer-vision-based locomotion scoring method to detect lameness and hoof lesions in dairy cows

    NARCIS (Netherlands)

    Schlageter-Tello, Andrés; Hertem, Van Tom; Bokkers, Eddie A.M.; Viazzi, Stefano; Bahr, Claudia; Lokhorst, Kees

    2018-01-01

    The objective of this study was to determine if a 3-dimensional computer vision automatic locomotion scoring (3D-ALS) method was able to outperform human observers for classifying cows as lame or nonlame and for detecting cows affected and nonaffected by specific type(s) of hoof lesion. Data

  12. Optical observations of southern planetary nebula candidates

    NARCIS (Netherlands)

    VandeSteene, GC; Sahu, KC; Pottasch, [No Value

    1996-01-01

    We present H alpha+[NII] images and low resolution spectra of 16 IRAS-selected, southern planetary nebula candidates previously detected in the radio continuum. The H alpha+[NII] images are presented as finding charts. Contour plots are shown for the resolved planetary nebulae. From these images

  13. Radiofrequency ablation of lung and liver lesions using CT fluoroscopy

    International Nuclear Information System (INIS)

    Chai, A.; Glenn, D.

    2002-01-01

    Full text: Tumour ablation with radiofrequency (RF) energy is a relatively new procedure for the treatment of focal malignant disease. At our institution this is currently being used in the treatment of certain liver and lung lesions with the patients involved being enrolled in clinical trials. The poster describes the technique used at our institution for the placement of the radiofrequency ablation electrode using CT fluoroscopy. Criteria for patient selection are included. Complications from the procedure are described, as well as follow up appearances and results. Our results from the treatment of primary and secondary lesions in the liver correlate well with published literature. Treatment is still not as successful as surgical resection but there is significantly less morbidity. Where this method may be appropriate is when the patient is not a candidate for surgical resection. The treatment of colorectal metastases in the lung shows early promise as a possible second line treatment (as for liver) where the patient is not a candidate for surgery. Preliminary results are soon to be published in conjunction with the Department of Surgery at our institution. RF Electrode placement using CT Fluoroscopy is performed at our institution. While still at its early stages, RF Ablation shows promise as a possible second line treatment (with other adjuvant therapy) for the management of focal malignant disease in the lung and liver. Copyright (2002) Blackwell Science Pty Ltd

  14. Can a Morel-Lavallée lesion be misdiagnosed as a mass like lesion?

    Science.gov (United States)

    Lee, Yoon Jae; Kim, Jun Hyeok; Kim, Ji Young; Han, Hyun Ho

    2017-12-01

    The Morel-Lavallée lesion (MLL) is a post-traumatic closed soft tissue degloving injury. Common complaints of MLL patients are a haematoma or fluid collection on the trunk or the lower extremity. However, the authors introduce unique cases of MLL that present an atypical appearance. The fluid collection was not apparent, and the capsule formation was not detected on preoperative image study. The main complaint of patients was the uncomfortable mass-like lesion that was regarded as a simple benign lump. The purpose of this case study is to introduce the atypical cases of MLL and to help other physicians make accurate diagnosis based on trial and error of our cases. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  15. Maxillomandibular giant osteosclerotic lesions

    Directory of Open Access Journals (Sweden)

    Constantino LEDESMA-MONTES

    2018-06-01

    Full Text Available Abstract Giant Osteosclerotic Lesions (GOLs are a group of rarely reported intraosseous lesions. Their precise diagnosis is important since they can be confused with malignant neoplasms. Objective This retrospective study aimed to record and analyze the clinical and radiographic Giant Osteosclerotic Lesions (GOLs detected in the maxillomandibular area of patients attending to our institution. Materials and Methods: Informed consent from the patients was obtained and those cases of 2.5 cm or larger lesions with radiopaque or mixed (radiolucid-radiopaque appearance located in the maxillofacial bones were selected. Assessed parameters were: age, gender, radiographic aspect, shape, borders, size, location and relations to roots. Lesions were classified as radicular, apical, interradicular, interradicular-apical, radicular-apical or located in a previous teeth extraction area. Additionally, several osseous and dental developmental alterations (DDAs were assessed. Results Seventeen radiopacities in 14 patients were found and were located almost exclusively in mandible and were two types: idiopathic osteosclerosis and condensing osteitis. GOLs were more frequent in females, and in the anterior and premolar zones. 94.2% of GOLs were qualified as idiopathic osteosclerosis and one case was condensing osteitis. All studied cases showed different osseous and dental developmental alterations (DDAs. The most common were: Microdontia, hypodontia, pulp stones, macrodontia and variations in the mental foramina. Conclusions GOLs must be differentiated from other radiopaque benign and malignant tumors. Condensing osteitis, was considered an anomalous osseous response induced by a chronic low-grade inflammatory stimulus. For development of idiopathic osteosclerosis, two possible mechanisms could be related. The first is modification of the normal turnover with excessive osseous deposition. The second mechanism will prevent the normal bone resorption, arresting the

  16. Magnetic resonance imaging of spinal cord lesions in multiple sclerosis

    International Nuclear Information System (INIS)

    Kojima, Shigeyuki; Yagishita, Toshiyuki; Fukutake, Toshio; Hirayama, Keizo; Fukuda, Nobuo.

    1987-01-01

    Magnetic resonance imaging (MRI) was used in three patients with multiple sclerosis (MS) to demonstrate the longitudinal distribution of demyelinating plaques in the spinal cord and to measure their T1 relaxation time values in these disease processes. Neurological examination allowed the detection of the superior limit of the spinal cord lesions in the three patients, but did not permit detection of the inferior limit in two of the patients. With MRI, however, it was possible to demonstrate the longitudinal distribution of demyelinating plaques in all three patients from coronal or sagittal images using spin echo and inversion recovery pulse sequences. In two patients treated with prednisolone, serial T1 relaxation time values of MS spinal cord lesions were measured from T1 calculated images. In one patient with transverse myelopathy, the T1 relaxation time values of MS spinal cord lesions were significantly increased at a stage of acute exacerbation. This is apparently in contrast with the values at the stage of remission. In the patient with localized cervical myelopathy, the increase in T1 relaxation time values of MS spinal cord lesions at the acute stage was small and significantly different from the values at the remission stage. Several recent reports have indicated that MRI is extremely sensitive in the detection of MS plaques, but most efforts to use MRI in the diagnosis of MS have been concentrated on brain lesions in spite of their frequent associations with spinal cord involvements. It is concluded from our case studies that MRI coronal or sagittal image is useful in demonstrating the longitudinal distribution of MS spinal cord lesions. In addition, serial observations of T1 relaxation time values of MS plaques may be important in assessing the activity of MS plaques and evaluation of the steroid therapy in MS processes. (author)

  17. Application of a global proteomic approach to archival precursor lesions: deleted in malignant brain tumors 1 and tissue transglutaminase 2 are upregulated in pancreatic cancer precursors

    DEFF Research Database (Denmark)

    Cheung, Wang; Darfler, Marlene M; Alvarez, Hector

    2008-01-01

    BACKGROUND: Pancreatic cancer is an almost uniformly fatal disease, and early detection is a critical determinant of improved survival. A variety of noninvasive precursor lesions of pancreatic adenocarcinoma have been identified, which provide a unique opportunity for intervention prior to onset ...... their overexpression in IPMNs. CONCLUSION: Global proteomics analysis using the Liquid Tissue workflow is a feasible approach for unbiased biomarker discovery in limited archival material, particularly applicable to precursor lesions of cancer......., and mass spectrometry to conduct a global proteomic analysis of an intraductal papillary mucinous neoplasm (IPMN). Tissue microarrays comprised of 38 IPMNs were used for validation of candidate proteins. RESULTS: The proteomic analysis of the IPMN Liquid Tissue lysate resulted in identification of 1......,534 peptides corresponding to 523 unique proteins. A subset of 25 proteins was identified that had previously been reported as upregulated in pancreatic cancer. Immunohistochemical analysis for two of these, deleted in malignant brain tumors 1 (DMBT1) and tissue transglutaminase 2 (TGM2), confirmed...

  18. Detection of intracavitary masses on gated scans: a phantom study

    International Nuclear Information System (INIS)

    Cho, B.; Yasuda, Tsunehiro; Moore, R.H.; Boucher, C.A.; Strauss, H.W.

    1987-01-01

    A series of 1.5, 2.0 and 3.0 cm diameter paraffin balls were placed on a 3 cm tether within a simulated left ventricular balloon phantom to determine the maximal balloon volume that permitted identification of the lesion. When images were recorded with the phantom stationary, the lesions could be detected at 100, 280 and 360 ml volumes, respectively. When the phantom was set in motion with a fixed 80 ml stroke volume, the lesions were detected at 120, 320 and 360 ml, respectively. These findings suggest that gating does not decrease lesion detection even when the lesion is freely mobile, and a 1.5 cm lesion would be difficult to detect in an enlarged ventricle, but 2 and 3 cm lesions could be detected even in the presence of moderate ventricular enlargement. (author)

  19. Bright intracranial lesions on diffusion-weighted images: a pictorial review

    International Nuclear Information System (INIS)

    Choi, Dae Seob

    2006-01-01

    Diffusion-weighted imaging (DWI) is a MR sequence that is used to evaluate the rate of microscopic water diffusion within the tissues. The ability to measure the rate of water diffusion is important because this is frequently altered in various disease processes. Generally, the lesions with restricted water diffusion show bright intensity on DWI, but the lesions without restricted water diffusion can also show bright intensity on DWI, which is called the 'T2 shine through effect'. With DWI, we can sensitively detect hyperacute infarction (within 6 hours after symptom onset), and this is difficult to detect with using CT and the conventional MR sequenced. The acute and subacute lesions of hypoxic-ischemic encephalopathy and carbon monoxide intoxication also show bright intensity on the DWI. The other diseases that can show bright intensity on the DWI include acute and subacute diffuse axonal injury lesion, hyperacute and late subacute hematomas, cerebral abscess, subdural empyema, acute herpes encephalitis, various tumors and such degenerative and demyelinating diseases as multiple sclerosis, posterior reversible encephalopathy syndrome, Wilson's disease and Wernicke's encephalopathy

  20. Bright intracranial lesions on diffusion-weighted images: a pictorial review

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Dae Seob [Gyeongsang National University College of Medicine, Jinju (Korea, Republic of)

    2006-06-15

    Diffusion-weighted imaging (DWI) is a MR sequence that is used to evaluate the rate of microscopic water diffusion within the tissues. The ability to measure the rate of water diffusion is important because this is frequently altered in various disease processes. Generally, the lesions with restricted water diffusion show bright intensity on DWI, but the lesions without restricted water diffusion can also show bright intensity on DWI, which is called the 'T2 shine through effect'. With DWI, we can sensitively detect hyperacute infarction (within 6 hours after symptom onset), and this is difficult to detect with using CT and the conventional MR sequenced. The acute and subacute lesions of hypoxic-ischemic encephalopathy and carbon monoxide intoxication also show bright intensity on the DWI. The other diseases that can show bright intensity on the DWI include acute and subacute diffuse axonal injury lesion, hyperacute and late subacute hematomas, cerebral abscess, subdural empyema, acute herpes encephalitis, various tumors and such degenerative and demyelinating diseases as multiple sclerosis, posterior reversible encephalopathy syndrome, Wilson's disease and Wernicke's encephalopathy.

  1. Characteristics of lesional and extra-lesional cortical grey matter in relapsing-remitting and secondary progressive multiple sclerosis: A magnetisation transfer and diffusion tensor imaging study.

    Science.gov (United States)

    Yaldizli, Özgür; Pardini, Matteo; Sethi, Varun; Muhlert, Nils; Liu, Zheng; Tozer, Daniel J; Samson, Rebecca S; Wheeler-Kingshott, Claudia Am; Yousry, Tarek A; Miller, David H; Chard, Declan T

    2016-02-01

    In multiple sclerosis (MS), diffusion tensor and magnetisation transfer imaging are both abnormal in lesional and extra-lesional cortical grey matter, but differences between clinical subtypes and associations with clinical outcomes have only been partly assessed. To compare mean diffusivity, fractional anisotropy and magnetisation transfer ratio (MTR) in cortical grey matter lesions (detected using phase-sensitive inversion recovery (PSIR) imaging) and extra-lesional cortical grey matter, and assess associations with disability in relapse-onset MS. Seventy-two people with MS (46 relapsing-remitting (RR), 26 secondary progressive (SP)) and 36 healthy controls were included in this study. MTR, mean diffusivity and fractional anisotropy were measured in lesional and extra-lesional cortical grey matter. Mean fractional anisotropy was higher and MTR lower in lesional compared with extra-lesional cortical grey matter. In extra-lesional cortical grey matter mean fractional anisotropy and MTR were lower, and mean diffusivity was higher in the MS group compared with controls. Mean MTR was lower and mean diffusivity was higher in lesional and extra-lesional cortical grey matter in SPMS when compared with RRMS. These differences were independent of disease duration. In multivariate analyses, MTR in extra-lesional more so than lesional cortical grey matter was associated with disability. Magnetic resonance abnormalities in lesional and extra-lesional cortical grey matter are greater in SPMS than RRMS. Changes in extra-lesional compared with lesional cortical grey matter are more consistently associated with disability. © The Author(s), 2015.

  2. The Use of Fluorescence Technology versus Visual and Tactile Examination in the Detection of Oral Lesions: A Pilot Study.

    Science.gov (United States)

    Ayoub, Hadeel M; Newcomb, Tara L; McCombs, Gayle B; Bonnie, Marshall

    2015-02-01

    This study compared the effectiveness of the VELscope® Vx versus visual and tactile intraoral examination in detecting oral lesions in an adult, high risk population. The pilot study compared the intra oral findings between 2 examination types. The sample was comprised of 30 participants who were addicted to either cigarettes or a dual addiction (cigarettes plus hookah). High risk population was defined as males who were current cigarette smokers or had a dual addiction. Two trained and experienced licensed dental hygienists conducted all examinations. Throughout the study, all visual and tactile intraoral examinations were conducted first by one dental hygienist first, followed by the VELscope® Vx fluorescence examinations by the second dental hygienist. All subjects received an inspection of the lips, labial and buccal mucosa, floor of the mouth, dorsal, ventral and lateral sides of the tongue, hard and soft palate, and visual inspection of the oropharynx and uvula. Both evaluations took place in 1 visit in the Dental Hygiene Research Center at Old Dominion University and external sites. All participants received oral cancer screening information, recommendations, referrals for tobacco cessation programs and brochures on the 2 types of examinations conducted. Participants were considered high risk based on demographics (current smokers and mostly males). Neither visual and tactile intraoral examination nor the VELscope® Vx examination showed positive lesions. No lesions were detected; therefore, no referrals were made. Data indicated the duration of tobacco use was significantly higher in cigarette smokers (14.1 years) than dual addiction smokers (5 years) (p>0.005). The average numbers of cigarettes smoked per day were 13.5 compared to 14.2 cigarettes for dual addiction smokers. Results from this study suggest the visual and tactile intraoral examination produced comparative results to the VELscope® Vx examination. Findings from this study support that the

  3. Scintigraphic evaluation of traumatic splenic lesions in children

    International Nuclear Information System (INIS)

    Erasmie, U.; Mortensson, W.; Persson, U.; Laennergren, K.; St. Goerans Children's Hospital, Stockholm

    1988-01-01

    Ninety-eight children with recent blunt abdominal trauma which initially evoked clinical suspicion of splenic injury were examined with colloid scintigraphy of the spleen and the liver using multiple imaging views and with abdominal survey. Nineteen children were, in addition, examined with tomographic scintigraphy. The clinical findings and the course of the disorder were reanalysed. Scintigraphy indicated splenic injury in 56 children and hepatic injury in another 5 children. The left lateral and the left oblique were the optimum imaging views for detecting splenic ruptures. Tomographic scintigraphy did not improve the diagnostic yield. Abdominal survey failed to indicate almost every second case of splenic rupture and provided no additional information of significance. The clinical review agreed with the scintigraphic diagnosis of splenic lesions but, in addition, it suggested possible splenic lesions in another 10 children with normal scintigraphy. This discrepancy cannot be explained as surgery was not employed; the occurrence of splenic lesions too small to become detectable at scintigraphy or to provoke clinically evident symptoms may be supposed. (orig.)

  4. Stroke subtype classification by geometrical descriptors of lesion shape.

    Directory of Open Access Journals (Sweden)

    Bastian Cheng

    Full Text Available Inference of etiology from lesion pattern in acute magnetic resonance imaging is valuable for management and prognosis of acute stroke patients. This study aims to assess the value of three-dimensional geometrical lesion-shape descriptors for stroke-subtype classification, specifically regarding stroke of cardioembolic origin.Stroke Etiology was classified according to ASCOD in retrospectively selected patients with acute stroke. Lesions were segmented on diffusion-weighed datasets, and descriptors of lesion shape quantified: surface area, sphericity, bounding box volume, and ratio between bounding box and lesion volume. Morphological measures were compared between stroke subtypes classified by ASCOD and between patients with embolic stroke of cardiac and non-cardiac source.150 patients (mean age 77 years; 95% CI, 65-80 years; median NIHSS 6, range 0-22 were included. Group comparison of lesion shape measures demonstrated that lesions caused by small-vessel disease were smaller and more spherical compared to other stroke subtypes. No significant differences of morphological measures were detected between patients with cardioembolic and non-cardioembolic stroke.Stroke lesions caused by small vessel disease can be distinguished from other stroke lesions based on distinctive morphological properties. However, within the group of embolic strokes, etiology could not be inferred from the morphology measures studied in our analysis.

  5. Usefulness of serum CA-15.3 in the management of benign breast lesion.

    Science.gov (United States)

    Mondal, Hari Pada; Roy, Himanshu; Mondal, Palash; Saha, Mita; Basu, Nandita

    2012-04-01

    Benign breast lesion is an important risk factor for breast cancer and elevated CA-15.3 in serum is a well established marker of breast cancer. Core-needle biopsy is now the method of choice to sample non-palpable mammographic abnormality and as well as clinically palpable lesion. To asses relationship of serum CA-15.3 with different histologic entities of benign breast lesion and usefulness of this marker in predicting breast cancer in this high risk group, a study was conducted among 140 patients who had a diagnosis of benign breast lesion and malignancy following fine needle aspiration cytology (FNAC) at department of surgery, Medical College, Kolkata between 2007 and 2009. We prospectively estimated serum CA-15.3 level in all patients. Different histologic entities of benign breast lesion, who showed serum CA-15.3 level >30U/ml underwent tru-cut biopsy to detect malignancy. Of 140 patients studied, 50 were stamped as malignancy and 90 as benign after FNAC of which 20 patients had fibroadenoma, 25 had fibro-adenoma with fibrocystic disease, 20 had fibrocystic disease with epitheliosis and 25 had fibrocystic disease with atypia. All breast cancer patients and 10 each from fibro-adenoma with fibrocystic disease, fibrocystic disease with epitheliosis and fibrocystic disease with atypia had serum CA -15.3 level>30U/ml. Thirty patients with benign breast lesion who had raised CA-15.3 underwent core-needle biopsy. Fifteen patients were detected to have intraductal carcinoma, mostly with fibrocystic disease with atypia. Clinical applicability of serum CA-15.3 to detect breast cancer should be strongly considered in management of patients with benign breast lesion and tru-cut biopsy than FNAC be done before benign breast lesion being stamped as benign. Biopsy results that are not concordant with the targeted lesion require surgical biopsy.

  6. Surgical treatment of gallbladder polypoid lesions

    Directory of Open Access Journals (Sweden)

    Pejić Miljko A.

    2003-01-01

    Full Text Available INTRODUCTION Polypoid lesions of the gallbladder can be divided into benign and malignant categories. Malignant polypoid lesions include carcinomas of the gallbladder, which is the fifth most common malignancy of the gastrointestinal tract and the most common malignancy of the biliary tract. Benign polypoid lesions of the gallbladder are divided into true tumors and pseudotumors. Pseudotumors account for most of polypoid lesions of the gallbladder, and include polyps, hyperplasia, and other miscellaneous lesions. Adenomas are the most common benign neoplasms of the gallbladder. Cholesterol polyps are the most common pseudotumors of the gallbladder. The polyps can be single or multiple, usually less than 10 mm in size. They have no predilection for any particular gallbladder site, and usually are attached to the gallbladder wall by a delicate, narrow pedicle. No malignant potential has been identified for this type of pseudotumor. Adenomas are the most common benign neoplasms of the gallbladder. They have no predilection site in the gallbladder, and may also be associated with gallstones or cholecystitis. The premalignant nature of adenomas remains controversial. Ultrasonography (US has been demonstrated to be significantly better in detecting polypoid lesions of the gallbladder as compared with computed tomography and cholecystography. A mass fixed to the gallbladder wall of normal thickness, without shadowing, is seen in case of gallbladder polyp. Since gallbladder cancers usually present as polypoid lesions, differentiation between benign polypoid lesion and malignant lesion can be very difficult, even with high-resolution imaging techniques. PATIENTS AND METHODS Retrospectively we have analyzed 38 patients with ultrasonographicaly detected gallbladder polyps during the period from January 1995 to December 2000, who were treated at surgical department of Health Centre in Uzice and at Surgical clinic of Clinical Centre in Nis. We have analyzed

  7. DENTAL LESIONS IN THE LOWLAND TAPIR (TAPIRUS TERRESTRIS).

    Science.gov (United States)

    Tjørnelund, Karen B; Jonsson, Lena M; Kortegaard, Hanne; Arnbjerg, Jens; Nielsen, Søren S; Bertelsen, Mads F

    2015-06-01

    Dental ailments, mandibular swelling, and dentoalveolar abscesses are common in tapirs, but knowledge about prevalence or etiology of these lesions in the Tapiridae family in general, and in lowland tapirs (Tapirus terrestris) in particular, is scarce. A recent study identified resorptive lesions of unknown etiology as a common problem in the Malayan tapir (Tapirus indicus). In order to investigate the type and prevalence of dental lesions occurring in lowland tapirs, and to compare these with findings with the Malayan tapir, skulls and teeth from 46 deceased lowland tapirs were visually and radiographically examined. The specimens were divided into subpopulations according to age (juveniles, young adults, adults) and origin (free-range or captive). Dental lesions were identified in 24% (11/46) of the study population. The most common pathologic findings were complicated dental fractures with associated periapical reaction (15%) and periapical reactions of various degrees without associated detectable dental pathology (13%). All these lesions likely originated from dental trauma. As in Malayan tapirs, juveniles had significantly fewer lesions than adults. This study shows that dental lesions present frequent problems for lowland tapirs, occurring both in captive and in free-ranging individuals, and indicates that increasing age should be considered a risk factor for the development of these lesions. Notably, the predominant dental problems in lowland tapirs and Malayan tapirs are not the same.

  8. Sclerotic bone lesions at abdominal magnetic resonance imaging in children with tuberous sclerosis complex

    Energy Technology Data Exchange (ETDEWEB)

    Boronat, Susana [Massachusetts General Hospital, Department of Neurology, Boston, MA (United States); Universitat Autonoma de Barcelona, Department of Pediatric Neurology, Vall d' Hebron Hospital, Barcelona (Spain); Barber, Ignasi [Universitat Autonoma de Barcelona, Department of Pediatric Radiology, Vall d' Hebron Hospital, Barcelona (Spain); Pargaonkar, Vivek [Massachusetts General Hospital, Department of Radiology, Boston, MA (United States); Chang, Joshua; Thiele, Elizabeth A. [Massachusetts General Hospital, Department of Neurology, Boston, MA (United States)

    2016-05-15

    Sclerotic bone lesions are often seen on chest CT in adults with tuberous sclerosis complex. To characterize bone lesions at abdominal MRI in children with tuberous sclerosis complex. This retrospective review included 70 children with tuberous sclerosis complex who had undergone abdominal MRI for renal imaging. An additional longitudinal study was performed in 50 children who had had two or more MRI scans. Abdominal CT (eight children) and radiographs (three children) were reviewed and compared with MRI. A total of 173 sclerotic bone lesions were detected in 51/70 children (73%; 95% confidence interval: 0.61-0.82) chiefly affecting vertebral pedicles. New lesions appeared in 20 children and growth of previous sclerotic bone lesions was documented in 14 children. Sclerotic bone lesions were more frequent in girls and in children with more extensive renal involvement. Sclerotic bone lesions are commonly detected by abdominal MRI in children with tuberous sclerosis complex. They usually affect posterior vertebral elements and their number and size increase with age. As current recommendations for tuberous sclerosis complex surveillance include renal MR performed in childhood, recognition of these lesions is useful. (orig.)

  9. Sclerotic bone lesions at abdominal magnetic resonance imaging in children with tuberous sclerosis complex

    International Nuclear Information System (INIS)

    Boronat, Susana; Barber, Ignasi; Pargaonkar, Vivek; Chang, Joshua; Thiele, Elizabeth A.

    2016-01-01

    Sclerotic bone lesions are often seen on chest CT in adults with tuberous sclerosis complex. To characterize bone lesions at abdominal MRI in children with tuberous sclerosis complex. This retrospective review included 70 children with tuberous sclerosis complex who had undergone abdominal MRI for renal imaging. An additional longitudinal study was performed in 50 children who had had two or more MRI scans. Abdominal CT (eight children) and radiographs (three children) were reviewed and compared with MRI. A total of 173 sclerotic bone lesions were detected in 51/70 children (73%; 95% confidence interval: 0.61-0.82) chiefly affecting vertebral pedicles. New lesions appeared in 20 children and growth of previous sclerotic bone lesions was documented in 14 children. Sclerotic bone lesions were more frequent in girls and in children with more extensive renal involvement. Sclerotic bone lesions are commonly detected by abdominal MRI in children with tuberous sclerosis complex. They usually affect posterior vertebral elements and their number and size increase with age. As current recommendations for tuberous sclerosis complex surveillance include renal MR performed in childhood, recognition of these lesions is useful. (orig.)

  10. Joint line tenderness and McMurray tests for the detection of meniscal lesions: what is their real diagnostic value?

    Science.gov (United States)

    Galli, Marco; Ciriello, Vincenzo; Menghi, Amerigo; Aulisa, Angelo G; Rabini, Alessia; Marzetti, Emanuele

    2013-06-01

    To assess the interobserver concordance of the joint line tenderness (JLT) and McMurray tests, and to determine their diagnostic efficiency for the detection of meniscal lesions. Prospective observational study. Orthopedics outpatient clinic, university hospital. Patients (N=60) with suspected nonacute meniscal lesions who underwent knee arthroscopy. Not applicable. Patients were examined by 3 independent observers with graded levels of experience (>10y, 3y, and 4mo of practice). The interobserver concordance was assessed by Cohen-Fleiss κ statistics. Accuracy, negative and positive predictive values for prevalence 10% to 90%, positive (LR+) and negative (LR-) likelihood ratios, and the Bayesian posttest probability with a positive or negative result were also determined. The diagnostic value of the 2 tests combined was assessed by logistic regression. Arthroscopy was used as the reference test. No interobserver concordance was determined for the JLT. The McMurray test showed higher interobserver concordance, which improved when judgments by the less experienced examiner were discarded. The whole series studied by the "best" examiner (experienced orthopedist) provided the following values: (1) JLT: sensitivity, 62.9%; specificity, 50%; LR+, 1.26; LR-, .74; (2) McMurray: sensitivity, 34.3%; specificity, 86.4%; LR+, 2.52; LR-, .76. The combination of the 2 tests did not offer advantages over the McMurray alone. The JLT alone is of little clinical usefulness. A negative McMurray test does not modify the pretest probability of a meniscal lesion, while a positive result has a fair predictive value. Hence, in a patient with a suspected meniscal lesion, a positive McMurray test indicates that arthroscopy should be performed. In case of a negative result, further examinations, including imaging, are needed. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  11. Venocentric lesions: an MRI marker of MS?

    Directory of Open Access Journals (Sweden)

    Matthew P. Quinn

    2013-07-01

    Full Text Available From the earliest descriptions of MS, the venocentric characteristic of plaques was noted. Recently, numerous MRI studies have proposed this finding as a prospective biomarker for MS, which might aid in differentiating MS from other diseases with similar MRI findings. High field MRI studies have shown that penetrating veins can be detected in most MS lesions using T2* weighted or susceptibility weighted imaging. Future studies must address the feasibility of imaging such veins in a clinically practical context. The specificity of this biomarker has been studied only in a limited capacity. Results in microangiopathic lesions are conflicting, whereas asymptomatic white matter hyperintensities as well as lesions of NMO are less frequently venocentric compared to MS plaques. Prospective studies have shown that the presence of venocentric lesions at an early clinical presentation is highly predictive of future MS diagnosis. This is very promising, but work remains to be done to confirm or exclude lesions of common MS mimics, such as ADEM, as venocentric. A number of technical challenges must be addressed before the introduction of this technique as a complementary tool in current diagnostic procedures.

  12. Comparison of diagnostic accuracy of {sup 111}In-pentetreotide SPECT and {sup 68}Ga-DOTATOC PET/CT: A lesion-by-lesion analysis in patients with metastatic neuroendocrine tumours

    Energy Technology Data Exchange (ETDEWEB)

    Binnebeek, S. van; Vanbilloen, B.; Baete, K.; Terwinghe, C.; Koole, M.; Mortelmans, L. [KU Leuven, Nuclear Medicine, University Hospitals Leuven and Department of Imaging and Pathology, Leuven (Belgium); Mottaghy, F.M. [Maastricht University Medical Center, Department of Nuclear Medicine, Maastricht (Netherlands); University Hospital Aachen, Department of Nuclear Medicine, Aachen (Germany); Clement, P.M. [KU Leuven, Medical Oncology, University Hospitals Leuven and Laboratory of Experimental Oncology, Leuven (Belgium); Bogaerts, K. [KU Leuven and UHasselt, Department of Public Health and Primary Care (I-BioStat), Leuven (Belgium); Haustermans, K. [KU Leuven, Radiation Oncology, University Hospitals Leuven and Department of Oncology, Leuven (Belgium); Nackaerts, K. [University Hospitals Leuven, Pulmonology, Leuven (Belgium); Cutsem, E. van; Verslype, C. [KU Leuven, Division of Digestive Oncology, University Hospitals Leuven and Department of Oncology, Leuven (Belgium); Verbruggen, A. [KU Leuven, Laboratory for Radiopharmacy, Leuven (Belgium); Deroose, C.M. [KU Leuven, Nuclear Medicine, University Hospitals Leuven and Department of Imaging and Pathology, Leuven (Belgium); University Hospitals Leuven, Nuclear Medicine, Leuven (Belgium)

    2016-03-15

    To compare the diagnostic accuracy of {sup 111}In-pentetreotide-scintigraphy with {sup 68}Ga-DOTATOC-positron emission tomography (PET)/computed tomography (CT) in patients with metastatic-neuroendocrine tumour (NET) scheduled for peptide receptor radionuclide therapy (PRRT). Incremental lesions (ILs) were defined as lesions observed on only one modality. Fifty-three metastatic-NET-patients underwent {sup 111}In-pentetreotide-scintigraphy (24 h post-injection; planar+single-photon emission CT (SPECT) abdomen) and whole-body {sup 68}Ga-DOTATOC-PET/CT. SPECT and PET were compared in a lesion-by-lesion and organ-by-organ analysis, determining the total lesions and ILs for both modalities. Significantly more lesions were detected on {sup 68}Ga-DOTATOC-PET/CT versus {sup 111}In-pentetreotide-scintigraphy. More specifically, we observed 1,098 lesions on PET/CT (range: 1-105; median: 15) versus 660 on SPECT (range: 0-73, median: 9) (p<0.0001), with 439 PET-ILs (42/53 patients) and one SPECT-IL (1/53 patients). The sensitivity for PET/CT was 99.9 % (95 % CI, 99.3-100.0), for SPECT 60.0 % (95 % CI, 48.5-70.2). The organ-by-organ analysis showed that the PET-ILs were most frequently visualized in liver and skeleton. Ga-DOTATOC-PET/CT is superior for the detection of NET-metastases compared to {sup 111}In-pentetreotide SPECT. (orig.)

  13. Globular domain of adiponectin: promising target molecule for detection of atherosclerotic lesions

    Science.gov (United States)

    Almer, Gunter; Saba-Lepek, Matthias; Haj-Yahya, Samih; Rohde, Eva; Strunk, Dirk; Fröhlich, Eleonore; Prassl, Ruth; Mangge, Harald

    2011-01-01

    Background: Adiponectin, an adipocyte-specific plasma protein, has been shown to accumulate in injured endothelial cells during development of atherosclerotic lesions. In this study, we investigated the potential of different adiponectin subfractions with special emphasis on globular adiponectin (gAd) to recognize and visualize atherosclerotic lesions. Methods: Recombinant mouse gAd and subfractions of full-length adiponectin (ie, trimeric, hexameric, and oligomeric forms) were fluorescence-labeled. Aortas of wild-type and apoprotein E-deficient mice fed a high cholesterol diet were dissected and incubated with the labeled biomarkers. Imaging was performed using confocal laser scanning microscopy. Results: Confocal laser scanning microscopic images showed that gAd binds more strongly to atherosclerotic plaques than full-length adiponectin subfractions. Further, we showed that gAd accumulates preferentially in endothelial cells and the fibrous cap area of plaques. Here we demonstrate for the first time that gAd recognizes atherosclerotic plaques on aortic sections of apoprotein E-deficient mice. Conclusion: These results suggest that gAd, in addition to its physiological properties, is also suitable as a target molecule for prospective diagnostic strategies in imaging atherosclerotic lesions. PMID:22022204

  14. Bone lesions in Chinese POEMS syndrome patients: imaging characteristics and clinical implications

    Directory of Open Access Journals (Sweden)

    Fengdan Wang

    2016-08-01

    Full Text Available Objective. Bone lesion is crucial for diagnosing and management of polyneuropathy, organomegaly, endocrinopathy, monoclonal protein, and skin change (POEMS syndrome, a rare plasma cell disorder. This study is to compare the effectiveness of X-ray skeletal survey (SS and computed tomography (CT for detecting bone lesions in Chinese POEMS syndrome patients, and to investigate the relationship between bone lesion features and serum markers. Methods. SS and chest/abdomen/pelvic CT images of 38 Chinese patients (26 males, 12 females, aged 21–70 years with POEMS syndrome recruited at our medical center between January 2013 and January 2015 were retrospectively analyzed. Bone lesions identified by CT were further categorized according to the size (10 mm and appearance (osteosclerotic, lytic, mixed. The percentage of plasma cells in bone marrow smears, type of immunoglobulin, platelet (Plt, and levels of serum bone metabolic markers and inflammatory factors including alkaline phosphatase (ALP, calcium, phosphate, parathyroid hormone (PTH, beta-isomerized C-telopeptide (β-CTx, vascular endothelial growth factor (VEGF, and interleukin (IL-6 levels were also recorded. Results. Of the 38 POEMS syndrome patients, the immunoglobulin heavy chain isotypes were IgA in 25 patients (65.8%; 25/38 and IgG in 13 patients (34.2%; 13/38, and the light chain isotypes were λ in 35 patients (92.1%; 35/38 and κ in 3 patients (7.9%; 3/38. There were 23 patients with thrombocytosis. More patients with bone lesions were detected by CT than by SS (97.4% vs. 86.8%. The most commonly affected location was the pelvis (89.5%, followed by the spine, clavicle/scapula/sternum/ribs, skull, and long bones. Of the 38 POEMS syndrome patients, 35 (94.6% had osteosclerotic and 32 (86.5% had mixed lesions. Osteosclerotic lesions were typically scattered, variable in size, and plaque-like, whereas mixed lesions were pouch-shaped or soup bubble-like with a clear sclerotic margin and were

  15. MR imaging of intracerebral hemorrhage lesions: Comparison of 2.0 T and 0.5 T images

    International Nuclear Information System (INIS)

    Han, Moon Hee; Chang, Kee Hyun

    1990-01-01

    Seventeen patients with intracerebral hemorrhage lesions were examined with magnetic resonance imaging at both 2.0 T and 0.5 T, in order to evaluate the capability of detecting and characterizing the hemorrhagic lesions at each field strength and to compare the signal intensities of the hemorrhages between both field strengths. The intervals between two imagings were within 2 hours in all patients except for 4 patients with subacute hematoma and occult cerebrovascular malformations in whom the intervals were 1 to 4 days. At each field strength, both T1 and T2-weighted spin echo(SE) images were obtained in all patients. All the hemorrhagic lesions were readily detected and characterized as hemorrhagic lesions at 2.0 T, whereas one lesion of chronic hemorrhage was not detected, and three lesions(one acute hemorrhage, one chronic hemorrhage and one occult cerebrovascular malformation) could not be characterized as hemorrhagic lesions at 0.5 T. There were statistically significant differences in signal intensity of the hematomas between 2.0 T and 0.5 T on proton density-weighted and T2-weighted images in cases of acute intracerebral hematomas: the hematomas seen as low intensity at 2.0 T appeared iso-or slightly high at 0.5 T. In conclusion, the intracerebral hematomas may be difficult to detect and to characterize with SE technique at 0.5 T, and then the gradient echo technique may be useful at 0.5 T

  16. Percutaneous aspiration biopsy in cervical spine lytic lesions

    International Nuclear Information System (INIS)

    Tampieri, D.; Weill, A.; Melanson, D.; Ethier, R.

    1991-01-01

    We describe the technique and the results of the percutaneous aspiration biopsy (PAB) in a series of 9 patients presenting with neck pain and different degrees of myelopathy, in whom the cervical spine X-ray demonstrated lytic lesions of unknown origin. PAB is a useful, relatively safe technique, and leads to histological diagnosis between metastatic and inflammatory processes. Furthermore, in inflammatory lesions with negative hemoculture, PAB may help in detecting the micro-organism responsible and therefore allow a better antibiotic treatment. (orig.)

  17. Metatranscriptomics reveals overall active bacterial composition in caries lesions

    Directory of Open Access Journals (Sweden)

    Aurea Simón-Soro

    2014-10-01

    Full Text Available Background: Identifying the microbial species in caries lesions is instrumental to determine the etiology of dental caries. However, a significant proportion of bacteria in carious lesions have not been cultured, and the use of molecular methods has been limited to DNA-based approaches, which detect both active and inactive or dead microorganisms. Objective: To identify the RNA-based, metabolically active bacterial composition of caries lesions at different stages of disease progression in order to provide a list of potential etiological agents of tooth decay. Design: Non-cavitated enamel caries lesions (n=15 and dentin caries lesions samples (n=12 were collected from 13 individuals. RNA was extracted and cDNA was constructed, which was used to amplify the 16S rRNA gene. The resulting 780 bp polymerase chain reaction products were pyrosequenced using Titanium-plus chemistry, and the sequences obtained were used to determine the bacterial composition. Results: A mean of 4,900 sequences of the 16S rRNA gene with an average read length of 661 bp was obtained per sample, giving a comprehensive view of the active bacterial communities in caries lesions. Estimates of bacterial diversity indicate that the microbiota of cavities is highly complex, each sample containing between 70 and 400 metabolically active species. The composition of these bacterial consortia varied among individuals and between caries lesions of the same individuals. In addition, enamel and dentin lesions had a different bacterial makeup. Lactobacilli were found almost exclusively in dentin cavities. Streptococci accounted for 40% of the total active community in enamel caries, and 20% in dentin caries. However, Streptococcus mutans represented only 0.02–0.73% of the total bacterial community. Conclusions: The data indicate that the etiology of dental caries is tissue dependent and that the disease has a clear polymicrobial origin. The low proportion of mutans streptococci

  18. Radiographic-guided fine-needle aspiration of nonpalpable breast lesions

    International Nuclear Information System (INIS)

    Helvie, M.A.; Baker, D.E.; Adler, D.D.; Andersson, I.; Naylor, B.; Buckwalter, K.

    1989-01-01

    The authors have performed radiographically guided fine-needle aspirations (FNA) on 215 nonpalpable mammographically detected breast lesions, using a coordinate grid localization system. Aspirates were classified into five cytologic groups. With the most stringent cytologic criteria, the sensitivity was 98% and the specificity 95% for the detection of carcinoma. However, according to these strict cytologic criteria, only 46% of aspirates contained representative material. Forty-two of 74 lesions undergoing biopsy proved malignant. Sixteen percent of patients did not compete adequate mammographic follow-up. High sensitivity and specificity can be achieved with radiographically guided FNA. However, management decisions ultimately require integration of mammographic findings with cytologic results. Close cooperation between mammographer, surgeon, cytopathologist, and patients is mandatory for successful operation

  19. WIMP dark matter candidates and searches—current status and future prospects

    Science.gov (United States)

    Roszkowski, Leszek; Sessolo, Enrico Maria; Trojanowski, Sebastian

    2018-06-01

    We review several current aspects of dark matter theory and experiment. We overview the present experimental status, which includes current bounds and recent claims and hints of a possible signal in a wide range of experiments: direct detection in underground laboratories, gamma-ray, cosmic ray, x-ray, neutrino telescopes, and the LHC. We briefly review several possible particle candidates for a weakly interactive massive particle (WIMP) and dark matter that have recently been considered in the literature. We pay particular attention to the lightest neutralino of supersymmetry as it remains the best motivated candidate for dark matter and also shows excellent detection prospects. Finally we briefly review some alternative scenarios that can considerably alter properties and prospects for the detection of dark matter obtained within the standard thermal WIMP paradigm.

  20. WIMP dark matter candidates and searches-current status and future prospects.

    Science.gov (United States)

    Roszkowski, Leszek; Sessolo, Enrico Maria; Trojanowski, Sebastian

    2018-06-01

    We review several current aspects of dark matter theory and experiment. We overview the present experimental status, which includes current bounds and recent claims and hints of a possible signal in a wide range of experiments: direct detection in underground laboratories, gamma-ray, cosmic ray, x-ray, neutrino telescopes, and the LHC. We briefly review several possible particle candidates for a weakly interactive massive particle (WIMP) and dark matter that have recently been considered in the literature. We pay particular attention to the lightest neutralino of supersymmetry as it remains the best motivated candidate for dark matter and also shows excellent detection prospects. Finally we briefly review some alternative scenarios that can considerably alter properties and prospects for the detection of dark matter obtained within the standard thermal WIMP paradigm.

  1. Fully automatic acute ischemic lesion segmentation in DWI using convolutional neural networks

    Directory of Open Access Journals (Sweden)

    Liang Chen

    2017-01-01

    Full Text Available Stroke is an acute cerebral vascular disease, which is likely to cause long-term disabilities and death. Acute ischemic lesions occur in most stroke patients. These lesions are treatable under accurate diagnosis and treatments. Although diffusion-weighted MR imaging (DWI is sensitive to these lesions, localizing and quantifying them manually is costly and challenging for clinicians. In this paper, we propose a novel framework to automatically segment stroke lesions in DWI. Our framework consists of two convolutional neural networks (CNNs: one is an ensemble of two DeconvNets (Noh et al., 2015, which is the EDD Net; the second CNN is the multi-scale convolutional label evaluation net (MUSCLE Net, which aims to evaluate the lesions detected by the EDD Net in order to remove potential false positives. To the best of our knowledge, it is the first attempt to solve this problem and using both CNNs achieves very good results. Furthermore, we study the network architectures and key configurations in detail to ensure the best performance. It is validated on a large dataset comprising clinical acquired DW images from 741 subjects. A mean accuracy of Dice coefficient obtained is 0.67 in total. The mean Dice scores based on subjects with only small and large lesions are 0.61 and 0.83, respectively. The lesion detection rate achieved is 0.94.

  2. Fully automatic acute ischemic lesion segmentation in DWI using convolutional neural networks.

    Science.gov (United States)

    Chen, Liang; Bentley, Paul; Rueckert, Daniel

    2017-01-01

    Stroke is an acute cerebral vascular disease, which is likely to cause long-term disabilities and death. Acute ischemic lesions occur in most stroke patients. These lesions are treatable under accurate diagnosis and treatments. Although diffusion-weighted MR imaging (DWI) is sensitive to these lesions, localizing and quantifying them manually is costly and challenging for clinicians. In this paper, we propose a novel framework to automatically segment stroke lesions in DWI. Our framework consists of two convolutional neural networks (CNNs): one is an ensemble of two DeconvNets (Noh et al., 2015), which is the EDD Net; the second CNN is the multi-scale convolutional label evaluation net (MUSCLE Net), which aims to evaluate the lesions detected by the EDD Net in order to remove potential false positives. To the best of our knowledge, it is the first attempt to solve this problem and using both CNNs achieves very good results. Furthermore, we study the network architectures and key configurations in detail to ensure the best performance. It is validated on a large dataset comprising clinical acquired DW images from 741 subjects. A mean accuracy of Dice coefficient obtained is 0.67 in total. The mean Dice scores based on subjects with only small and large lesions are 0.61 and 0.83, respectively. The lesion detection rate achieved is 0.94.

  3. Proteomic profiling reveals candidate markers for arsenic-induced skin keratosis.

    Science.gov (United States)

    Guo, Zhiling; Hu, Qin; Tian, Jijing; Yan, Li; Jing, Chuanyong; Xie, Heidi Qunhui; Bao, Wenjun; Rice, Robert H; Zhao, Bin; Jiang, Guibin

    2016-11-01

    Proteomics technology is an attractive biomarker candidate discovery tool that can be applied to study large sets of biological molecules. To identify novel biomarkers and molecular targets in arsenic-induced skin lesions, we have determined the protein profile of arsenic-affected human epidermal stratum corneum by shotgun proteomics. Samples of palm and foot sole from healthy subjects were analyzed, demonstrating similar protein patterns in palm and sole. Samples were collected from the palms of subjects with arsenic keratosis (lesional and adjacent non-lesional samples) and arsenic-exposed subjects without lesions (normal). Samples from non-exposed healthy individuals served as controls. We found that three proteins in arsenic-exposed lesional epidermis were consistently distinguishably expressed from the unaffected epidermis. One of these proteins, the cadherin-like transmembrane glycoprotein, desmoglein 1 (DSG1) was suppressed. Down-regulation of DSG1 may lead to reduced cell-cell adhesion, resulting in abnormal epidermal differentiation. The expression of keratin 6c (KRT6C) and fatty acid binding protein 5 (FABP5) were significantly increased. FABP5 is an intracellular lipid chaperone that plays an essential role in fatty acid metabolism in human skin. This raises a possibility that overexpression of FABP5 may affect the proliferation or differentiation of keratinocytes by altering lipid metabolism. KRT6C is a constituent of the cytoskeleton that maintains epidermal integrity and cohesion. Abnormal expression of KRT6C may affect its structural role in the epidermis. Our findings suggest an important approach for future studies of arsenic-mediated toxicity and skin cancer, where certain proteins may represent useful biomarkers of early diagnoses in high-risk populations and hopefully new treatment targets. Further studies are required to understand the biological role of these markers in skin pathogenesis from arsenic exposure. Copyright © 2016 Elsevier Ltd

  4. Respiratory function after lesions in medulla oblongata.

    Science.gov (United States)

    Woischneck, Dieter; Kapapa, Thomas; Heissler, Hans E; Reissberg, Steffen; Skalej, Martin; Firsching, Raimund

    2009-12-01

    To evaluate the correlation of lesions of the brain as visualized in cranial magnetic resonance imaging (MRI) and the ability of spontaneous respiration. In a prospective concept, cranial MRI after traumatic brain injury or spontaneous intracerebral hemorrhage was performed in 250 subjects at an early stage. All MRI findings were correlated with respiratory conditions on the day of examination. Sedation was performed only to facilitate toleration of the artificial ventilation, as and when necessary. Spontaneous respiration could hence be registered clinically. Thirteen subjects (5.2%) had no spontaneous respiration. In these cases, a bilateral lesion of the distal medulla oblongata could be displayed. In four of these cases, no additional injuries of the brainstem were detected. These subjects awoke 2 days after the impact with tetraparesis and apnea. Combined lesions of the medulla oblongata and other brainstem regions were found in nine subjects. All these patients died without awakening. In the absence of a bilateral lesion of the caudal medulla oblongata, spontaneous respiration was always possible. A unilateral lesion of the caudal medulla oblongata was visualized in one patient who had the ability of spontaneous respiration. This work confirms the presence of autonomous respiratory centers within the caudal medulla oblongata that allows sufficient adequate respiration in coma. Respiration ceases in the presence of a bilateral lesion of this area.

  5. Resolved Companions of Cepheids: Testing the Candidates with X-Ray Observations

    Science.gov (United States)

    Evans, Nancy Remage; Pillitteri, Ignazio; Wolk, Scott; Karovska, Margarita; Tingle, Evan; Guinan, Edward; Engle, Scott; Bond, Howard E.; Schaefer, Gail H.; Mason, Brian D.

    2016-04-01

    We have made XMM-Newton observations of 14 Galactic Cepheids that have candidate resolved (≥5″) companion stars based on our earlier HST Wide Field Camera 3 (WFC3) imaging survey. Main-sequence stars that are young enough to be physical companions of Cepheids are expected to be strong X-ray producers in contrast to field stars. XMM-Newton exposures were set to detect essentially all companions hotter than spectral type M0 (corresponding to 0.5 M⊙). The large majority of our candidate companions were not detected in X-rays, and hence are not confirmed as young companions. One resolved candidate (S Nor #4) was unambiguously detected, but the Cepheid is a member of a populous cluster. For this reason, it is likely that S Nor #4 is a cluster member rather than a gravitationally bound companion. Two further Cepheids (S Mus and R Cru) have X-ray emission that might be produced by either the Cepheid or the candidate resolved companion. A subsequent Chandra observation of S Mus shows that the X-rays are at the location of the Cepheid/spectroscopic binary. R Cru and also V659 Cen (also X-ray bright) have possible companions closer than 5″ (the limit for this study) which are the likely sources of X-rays. One final X-ray detection (V473 Lyr) has no known optical companion, so the prime suspect is the Cepheid itself. It is a unique Cepheid with a variable amplitude. The 14 stars that we observed with XMM constitute 36% of the 39 Cepheids found to have candidate companions in our HST/WFC3 optical survey. No young probable binary companions were found with separations of ≥5″ or 4000 au. Based on observations obtained with XMM-Newton, an ESA science mission with instruments and contributions directly funded by ESA Member States and the USA (NASA).

  6. PEACE: pulsar evaluation algorithm for candidate extraction - a software package for post-analysis processing of pulsar survey candidates

    Science.gov (United States)

    Lee, K. J.; Stovall, K.; Jenet, F. A.; Martinez, J.; Dartez, L. P.; Mata, A.; Lunsford, G.; Cohen, S.; Biwer, C. M.; Rohr, M.; Flanigan, J.; Walker, A.; Banaszak, S.; Allen, B.; Barr, E. D.; Bhat, N. D. R.; Bogdanov, S.; Brazier, A.; Camilo, F.; Champion, D. J.; Chatterjee, S.; Cordes, J.; Crawford, F.; Deneva, J.; Desvignes, G.; Ferdman, R. D.; Freire, P.; Hessels, J. W. T.; Karuppusamy, R.; Kaspi, V. M.; Knispel, B.; Kramer, M.; Lazarus, P.; Lynch, R.; Lyne, A.; McLaughlin, M.; Ransom, S.; Scholz, P.; Siemens, X.; Spitler, L.; Stairs, I.; Tan, M.; van Leeuwen, J.; Zhu, W. W.

    2013-07-01

    Modern radio pulsar surveys produce a large volume of prospective candidates, the majority of which are polluted by human-created radio frequency interference or other forms of noise. Typically, large numbers of candidates need to be visually inspected in order to determine if they are real pulsars. This process can be labour intensive. In this paper, we introduce an algorithm called Pulsar Evaluation Algorithm for Candidate Extraction (PEACE) which improves the efficiency of identifying pulsar signals. The algorithm ranks the candidates based on a score function. Unlike popular machine-learning-based algorithms, no prior training data sets are required. This algorithm has been applied to data from several large-scale radio pulsar surveys. Using the human-based ranking results generated by students in the Arecibo Remote Command Center programme, the statistical performance of PEACE was evaluated. It was found that PEACE ranked 68 per cent of the student-identified pulsars within the top 0.17 per cent of sorted candidates, 95 per cent within the top 0.34 per cent and 100 per cent within the top 3.7 per cent. This clearly demonstrates that PEACE significantly increases the pulsar identification rate by a factor of about 50 to 1000. To date, PEACE has been directly responsible for the discovery of 47 new pulsars, 5 of which are millisecond pulsars that may be useful for pulsar timing based gravitational-wave detection projects.

  7. Magnetic resonance (MR) colonography in the detection of colorectal lesions: a systematic review of prospective studies

    International Nuclear Information System (INIS)

    Zijta, Frank M.; Bipat, Shandra; Stoker, Jaap

    2010-01-01

    To determine the diagnostic accuracy of MR-colonography for the detection of colorectal lesions. A comprehensive literature search was performed for comparative MR-colonography studies, published between May 1997 and February 2009, using the MEDLINE, EMBASE and Cochrane databases. We included studies if MR-colonography findings were prospectively compared with conventional colonoscopy in (a)symptomatic patients. Two reviewers independently extracted study design characteristics and data for summarising sensitivity and specificity. Heterogeneity in findings between studies was tested using I 2 test statistics. Sensitivity and specificity estimates with 95% confidence intervals (CI) were calculated on per patient basis and summary sensitivity on per polyp basis, using bivariate and univariate statistical models. Thirty-seven studies were found to be potentially relevant and 13 fulfilled the inclusion criteria. The study population comprised 1,285 patients with a mean disease prevalence of 44% (range 22-63%). Sensitivity for the detection of CRC was 100%. Significant heterogeneity was found for overall per patient sensitivity and specificity. For polyps with a size of 10 mm or larger, per patient sensitivity and specificity estimates were 88% (95% CI 63-97%; I 2 = 37%) and 99% (95% CI 95-100%; I 2 = 60%). On a per polyp basis, polyps of 10 mm or larger were detected with a sensitivity of 84% (95% CI 66-94%; I 2 = 51%). The data were too heterogeneous for polyps smaller than 6 mm and 6-9 mm. MR-colonography can accurately detect colorectal polyps more than 10 mm in size. (orig.)

  8. Radiological appearances of papillary breast lesions

    International Nuclear Information System (INIS)

    Brookes, M.J.; Bourke, A.G.

    2008-01-01

    This review illustrates the varied appearances of benign and malignant papillary breast tumours, as identified by a breast cancer-screening programme. The commonest mammographic appearance of a papillary tumour is as a soft-tissue mass, with calcification present in less than half of cases. When calcification is present the pattern is variable, but clusters of pleomorphic calcification can occur, sometimes resembling the mammographic appearance of invasive ductal carcinoma. Ultrasonography of papillary lesions typically shows a solid, oval, intraductal mass, often associated with duct dilatation. A cystic component is also commonly seen, and lesions may appear hypervascular on colour Doppler ultrasound. Magnetic resonance imaging (MRI) has a high sensitivity, but low specificity for detecting papillary tumours, and is useful in establishing the extent and distribution of lesions in patients with multiple papillomatosis. Despite a benign histology on core biopsy, an argument exists for complete surgical excision of all papillary tumours, as a significant proportion of papillomas will contain foci of atypia or overt malignant change

  9. Radiological appearances of papillary breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Brookes, M.J. [Sir Charles Gairdner Hospital, Nedlands, Perth, Western Australia (Australia)], E-mail: mattbrookes@doctors.org.uk; Bourke, A.G. [Sir Charles Gairdner Hospital, Nedlands, Perth, Western Australia (Australia)

    2008-11-15

    This review illustrates the varied appearances of benign and malignant papillary breast tumours, as identified by a breast cancer-screening programme. The commonest mammographic appearance of a papillary tumour is as a soft-tissue mass, with calcification present in less than half of cases. When calcification is present the pattern is variable, but clusters of pleomorphic calcification can occur, sometimes resembling the mammographic appearance of invasive ductal carcinoma. Ultrasonography of papillary lesions typically shows a solid, oval, intraductal mass, often associated with duct dilatation. A cystic component is also commonly seen, and lesions may appear hypervascular on colour Doppler ultrasound. Magnetic resonance imaging (MRI) has a high sensitivity, but low specificity for detecting papillary tumours, and is useful in establishing the extent and distribution of lesions in patients with multiple papillomatosis. Despite a benign histology on core biopsy, an argument exists for complete surgical excision of all papillary tumours, as a significant proportion of papillomas will contain foci of atypia or overt malignant change.

  10. Contrast-enhanced spectral mammography (CESM) versus breast magnetic resonance imaging (MRI): A retrospective comparison in 66 breast lesions.

    Science.gov (United States)

    Li, L; Roth, R; Germaine, P; Ren, S; Lee, M; Hunter, K; Tinney, E; Liao, L

    2017-02-01

    The purpose of this study was to retrospectively compare the diagnostic performance of contrast-enhanced spectral mammography (CESM) with that of breast magnetic resonance imaging (BMRI) in breast cancer detection using parameters, including sensitivity, positive predictive value (PPV), lesion size, morphology, lesion and background enhancement, and examination time. A total of 48 women (mean age, 56years±10.6 [SD]) with breast lesions detected between October 2012 and March 2014 were included. Both CESM and BMRI were performed for each patient within 30 days. The enhancement intensity of lesions and breast background parenchyma was subjectively assessed for both modalities and was quantified for comparison. Statistical significance was analyzed using paired t-test for mean size of index lesions in all malignant breasts (an index lesion defined as the largest lesion in each breast), and a mean score of enhancement intensity for index lesions and breast background. PPV, sensitivity, and accuracy were calculated for both CESM and BMRI. The average duration time of CESM and MRI examinations was also compared. A total of 66 lesions were identified, including 62 malignant and 4 benign lesions. Both CESM and BMRI demonstrated a sensitivity of 100% for detection of breast cancer. There was no statistically significant difference between the mean size of index lesions (P=0.108). The enhancement intensity of breast background was significantly lower for CESM than for BMRI (P0.05). The average examination time for CESM was significantly shorter than that of BMRI (P<0.01). CESM has similar sensitivity than BMRI in breast cancer detection, with higher PPV and less background enhancement. CESM is associate with significantly shorter exam time thus a more accessible alternative to BMRI, and has the potential to play an important tool in breast cancer detection and staging. Copyright © 2016 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights

  11. Detection of precancerous lesions in the oral cavity using oblique polarized reflectance spectroscopy: a clinical feasibility study

    Science.gov (United States)

    Bailey, Maria J.; Verma, Nishant; Fradkin, Leonid; Lam, Sylvia; MacAulay, Calum; Poh, Catherine; Markey, Mia K.; Sokolov, Konstantin

    2017-06-01

    We developed a multifiber optical probe for oblique polarized reflectance spectroscopy (OPRS) in vivo and evaluated its performance in detection of dysplasia in the oral cavity. The probe design allows the implementation of a number of methods to enable depth resolved spectroscopic measurements including polarization gating, source-detector separation, and differential spectroscopy; this combination was evaluated in carrying out binary classification tasks between four major diagnostic categories: normal, benign, mild dysplasia (MD), and severe dysplasia (SD). Multifiber OPRS showed excellent performance in the discrimination of normal from benign, MD, SD, and MD plus SD yielding sensitivity/specificity values of 100%/93%, 96%/95%, 100%/98%, and 100%/100%, respectively. The classification of benign versus dysplastic lesions was more challenging with sensitivity and specificity values of 80%/93%, 71%/93%, and 74%/80% in discriminating benign from SD, MD, and SD plus MD categories, respectively; this challenge is most likely associated with a strong and highly variable scattering from a keratin layer that was found in these sites. Classification based on multiple fibers was significantly better than that based on any single detection pair for tasks dealing with benign versus dysplastic sites. This result indicates that the multifiber probe can perform better in the detection of dysplasia in keratinized tissues.

  12. Dissecting the organ specificity of insecticide resistance candidate genes in Anopheles gambiae: known and novel candidate genes.

    Science.gov (United States)

    Ingham, Victoria A; Jones, Christopher M; Pignatelli, Patricia; Balabanidou, Vasileia; Vontas, John; Wagstaff, Simon C; Moore, Jonathan D; Ranson, Hilary

    2014-11-25

    The elevated expression of enzymes with insecticide metabolism activity can lead to high levels of insecticide resistance in the malaria vector, Anopheles gambiae. In this study, adult female mosquitoes from an insecticide susceptible and resistant strain were dissected into four different body parts. RNA from each of these samples was used in microarray analysis to determine the enrichment patterns of the key detoxification gene families within the mosquito and to identify additional candidate insecticide resistance genes that may have been overlooked in previous experiments on whole organisms. A general enrichment in the transcription of genes from the four major detoxification gene families (carboxylesterases, glutathione transferases, UDP glucornyltransferases and cytochrome P450s) was observed in the midgut and malpighian tubules. Yet the subset of P450 genes that have previously been implicated in insecticide resistance in An gambiae, show a surprisingly varied profile of tissue enrichment, confirmed by qPCR and, for three candidates, by immunostaining. A stringent selection process was used to define a list of 105 genes that are significantly (p ≤0.001) over expressed in body parts from the resistant versus susceptible strain. Over half of these, including all the cytochrome P450s on this list, were identified in previous whole organism comparisons between the strains, but several new candidates were detected, notably from comparisons of the transcriptomes from dissected abdomen integuments. The use of RNA extracted from the whole organism to identify candidate insecticide resistance genes has a risk of missing candidates if key genes responsible for the phenotype have restricted expression within the body and/or are over expression only in certain tissues. However, as transcription of genes implicated in metabolic resistance to insecticides is not enriched in any one single organ, comparison of the transcriptome of individual dissected body parts cannot

  13. Human brain lesion-deficit inference remapped.

    Science.gov (United States)

    Mah, Yee-Haur; Husain, Masud; Rees, Geraint; Nachev, Parashkev

    2014-09-01

    Our knowledge of the anatomical organization of the human brain in health and disease draws heavily on the study of patients with focal brain lesions. Historically the first method of mapping brain function, it is still potentially the most powerful, establishing the necessity of any putative neural substrate for a given function or deficit. Great inferential power, however, carries a crucial vulnerability: without stronger alternatives any consistent error cannot be easily detected. A hitherto unexamined source of such error is the structure of the high-dimensional distribution of patterns of focal damage, especially in ischaemic injury-the commonest aetiology in lesion-deficit studies-where the anatomy is naturally shaped by the architecture of the vascular tree. This distribution is so complex that analysis of lesion data sets of conventional size cannot illuminate its structure, leaving us in the dark about the presence or absence of such error. To examine this crucial question we assembled the largest known set of focal brain lesions (n = 581), derived from unselected patients with acute ischaemic injury (mean age = 62.3 years, standard deviation = 17.8, male:female ratio = 0.547), visualized with diffusion-weighted magnetic resonance imaging, and processed with validated automated lesion segmentation routines. High-dimensional analysis of this data revealed a hidden bias within the multivariate patterns of damage that will consistently distort lesion-deficit maps, displacing inferred critical regions from their true locations, in a manner opaque to replication. Quantifying the size of this mislocalization demonstrates that past lesion-deficit relationships estimated with conventional inferential methodology are likely to be significantly displaced, by a magnitude dependent on the unknown underlying lesion-deficit relationship itself. Past studies therefore cannot be retrospectively corrected, except by new knowledge that would render them redundant

  14. Ultrasonographic findings of breast lesions

    International Nuclear Information System (INIS)

    Hwang, In Sung; Kim, Yang Soo; Suh, Hyoung Sim

    1990-01-01

    Authors retrospectively analyzed ultrasonographic findings of 61 cases of breast lesions which were proven pathologically at Daerim St. Mary's Hospital from May 1987 to February 1990. The results were as follows : 1. Of all 61 cases, there were 27 fibroadenomas, 13 fibrocystic diseases, 11 carcinomas, 8 abscesses, 1 sclerosing adenosis, and 1 intraductal papilloma. 2. Findings suggesting benignancy were smooth contour, round or oval shape, homogeneously echolucent internal echo, echogenic boundary echo, and posterior enhancement. In the cases of abscess, the findings were rather irregular contour, strong posterior enhancement, and dirty, inhomogeneous internal echo. While irregular and lobulated shape, inhomogeneous and mixed internal echo and pectoral muscle invasion were suggested for malignancy. 3. The sensitivity was 98% and the specificity 58% in benign mass excluding abscesses, 63% and 98% in abscesses, and 55% and 98% in carcinomas. In conclusion, ultrasonography is one of the excellent imaging modality for detecting breast lesions larger than 5 mm in size, but unfortunately some of the malignant tumors simulated benignancy, thus we considered fine needle aspiration biopsy and adjunctive imaging modalities such as film mammography must be followed for better detection of breast cancer

  15. Ultrasonographic findings of breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, In Sung; Kim, Yang Soo; Suh, Hyoung Sim [College of Medicine, Daerim St. Mary' s Hospital, Seoul (Korea, Republic of)

    1990-07-15

    Authors retrospectively analyzed ultrasonographic findings of 61 cases of breast lesions which were proven pathologically at Daerim St. Mary's Hospital from May 1987 to February 1990. The results were as follows : 1. Of all 61 cases, there were 27 fibroadenomas, 13 fibrocystic diseases, 11 carcinomas, 8 abscesses, 1 sclerosing adenosis, and 1 intraductal papilloma. 2. Findings suggesting benignancy were smooth contour, round or oval shape, homogeneously echolucent internal echo, echogenic boundary echo, and posterior enhancement. In the cases of abscess, the findings were rather irregular contour, strong posterior enhancement, and dirty, inhomogeneous internal echo. While irregular and lobulated shape, inhomogeneous and mixed internal echo and pectoral muscle invasion were suggested for malignancy. 3. The sensitivity was 98% and the specificity 58% in benign mass excluding abscesses, 63% and 98% in abscesses, and 55% and 98% in carcinomas. In conclusion, ultrasonography is one of the excellent imaging modality for detecting breast lesions larger than 5 mm in size, but unfortunately some of the malignant tumors simulated benignancy, thus we considered fine needle aspiration biopsy and adjunctive imaging modalities such as film mammography must be followed for better detection of breast cancer.

  16. Candidates for non-baryonic dark matter

    International Nuclear Information System (INIS)

    Fornengo, Nicolao

    2002-01-01

    This report is a brief review of the efforts to explain the nature of non-baryonic dark matter and of the studies devoted to the search for relic particles. Among the different dark matter candidates, special attention is devoted to relic neutralinos, by giving an overview of the recent calculations of its relic abundance and detection rates in a wide variety of supersymmetric schemes

  17. Candidates for non-baryonic dark matter

    OpenAIRE

    Fornengo, Nicolao

    2002-01-01

    This report is a brief review of the efforts to explain the nature of non-baryonic dark matter and of the studies devoted to the search for relic particles. Among the different dark matter candidates, special attention is devoted to relic neutralinos, by giving an overview of the recent calculations of its relic abundance and detection rates in a wide variety of supersymmetric schemes.

  18. Contrast between hypervascularized liver lesions and hepatic parenchyma. Early dynamic PET versus contrast-enhanced CT

    International Nuclear Information System (INIS)

    Freesmeyer, M.; Winkens, T.; Schierz, J.-H.

    2014-01-01

    To detect hypervascularized liver lesions, early dynamic (ED) 18 F-FDG PET may be an alternative when contrast-enhanced (CE) imaging is infeasible. This retrospective pilot analysis compared contrast between such lesions and liver parenchyma, an important objective image quality variable, in ED PET versus CE CT. Twenty-eight hypervascularized liver lesions detected by CE CT [21 (75%) hepatocellular carcinomas; mean (range) diameter 4.9 ± 3.5 (1-14) cm] in 20 patients were scanned with ED PET. Using regions of interest, maximum and mean lesional and parenchymal signals at baseline, arterial and venous phases were calculated for ED PET and CE CT. Lesional/parenchymal signal ratio was significantly higher (P < 0.005) with ED PET versus CE CT at the arterial phase and similar between the methods at the venous phase. In liver imaging, ED PET generates greater lesional-parenchymal contrast during the arterial phase than does CE CT; these observations should be formally, prospectively evaluated. (author)

  19. Computer-aided detection of bladder wall thickening in CT urography (CTU)

    Science.gov (United States)

    Cha, Kenny H.; Hadjiiski, Lubomir M.; Chan, Heang-Ping; Caoili, Elaine M.; Cohan, Richard H.; Weizer, Alon Z.; Gordon, Marshall N.; Samala, Ravi K.

    2018-02-01

    We are developing a computer-aided detection system for bladder cancer in CT urography (CTU). Bladder wall thickening is a manifestation of bladder cancer and its detection is more challenging than the detection of bladder masses. We first segmented the inner and outer bladder walls using our method that combined deep-learning convolutional neural network with level sets. The non-contrast-enhanced region was separated from the contrast-enhanced region with a maximum-intensity-projection-based method. The non-contrast region was smoothed and gray level threshold was applied to the contrast and non-contrast regions separately to extract the bladder wall and potential lesions. The bladder wall was transformed into a straightened thickness profile, which was analyzed to identify regions of wall thickening candidates. Volume-based features of the wall thickening candidates were analyzed with linear discriminant analysis (LDA) to differentiate bladder wall thickenings from false positives. A data set of 112 patients, 87 with wall thickening and 25 with normal bladders, was collected retrospectively with IRB approval, and split into independent training and test sets. Of the 57 training cases, 44 had bladder wall thickening and 13 were normal. Of the 55 test cases, 43 had wall thickening and 12 were normal. The LDA classifier was trained with the training set and evaluated with the test set. FROC analysis showed that the system achieved sensitivities of 93.2% and 88.4% for the training and test sets, respectively, at 0.5 FPs/case.

  20. Constraints on light WIMP candidates from the isotropic diffuse gamma-ray emission

    International Nuclear Information System (INIS)

    Arina, Chiara; Tytgat, Michel H.G.

    2011-01-01

    Motivated by the measurements reported by direct detection experiments, most notably DAMA, CDMS-II, CoGeNT and Xenon10/100, we study further the constraints that might be set on some light dark matter candidates, M DM ∼ few GeV, using the Fermi-LAT data on the isotropic gamma-ray diffuse emission. In particular, we consider a Dirac fermion singlet interacting through a new Z' gauge boson, and a scalar singlet S interacting through the Higgs portal. Both candidates are WIMP (Weakly Interacting Massive Particles), i.e. they have an annihilation cross-section in the pbarn range. Also they may both have a spin-independent elastic cross section on nucleons in the range required by direct detection experiments. Although being generic WIMP candidates, because they have different interactions with Standard Model particles, their phenomenology regarding the isotropic diffuse gamma-ray emission is quite distinct. In the case of the scalar singlet, the one-to-one correspondence between its annihilation cross-section and its spin-independent elastic scattering cross-section permits to express the constraints from the Fermi-LAT data in the direct detection exclusion plot, σ n 0 −M DM . Depending on the astrophysics, we argue that it is possible to exclude the singlet scalar dark matter candidate at 95% confidence level. The constraints on the Dirac singlet interacting through a Z' are comparatively weaker