WorldWideScience

Sample records for leoni 1578-1630 image

  1. Ocean to Outback: Leonie Rennie's Contribution to Science Education in Australia

    Science.gov (United States)

    Venville, Grady

    2009-01-01

    In this article I initially borrow a metaphor from an art exhibition, "Ocean to Outback," as a way to express my perspective on the contribution that Leonie Rennie has made to science education in Australia. I then consider Leonie's contributions as overlapping themes. In particular, Leonie's well-known research on gender and issues of…

  2. 21 CFR 892.1630 - Electrostatic x-ray imaging system.

    Science.gov (United States)

    2010-04-01

    ... system. (a) Identification. An electrostatic x-ray imaging system is a device intended for medical... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electrostatic x-ray imaging system. 892.1630... visible image. This generic type of device may include signal analysis and display equipment, patient and...

  3. Exocomet Signatures Around the A-shell Star Phi Leonis

    Science.gov (United States)

    Eiroa, C.; Rebollido, I.; Montesinos, B.; Villaver, E.; Absil, O.; Henning, Th.; Bayo, A.; Canovas, H.; Carmona, A.; Chen, Ch.; hide

    2016-01-01

    We present an intensive monitoring of high-resolution spectra of the Ca II K line in the A7IV shell star Phi Leonis at very short (minutes, hours), short (night to night), and medium (weeks, months) timescales. The spectra show remarkable variable absorptions on timescales of hours, days, and months. The characteristics of these sporadic events are very similar to most that are observed toward the debris disk host star Beta Pictoris, which are commonly interpreted as signs of the evaporation of solid, comet-like bodies grazing or falling onto the star. Therefore, our results suggest the presence of solid bodies around Phi Leonis. To our knowledge, with the exception of Beta Pictoris, our monitoring has the best time resolution at the mentioned timescales for a star with events attributed to exocomets. Assuming the cometary scenario and considering the timescales of our monitoring, our results indicate that Phi Leonis presents the richest environment with comet-like events known to date, second only to Beta Pictoris.

  4. 7 CFR 51.1578 - Off-Grade potatoes.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Off-Grade potatoes. 51.1578 Section 51.1578... STANDARDS) United States Consumer Standards for Potatoes Off-Grade § 51.1578 Off-Grade potatoes. Potatoes which fail to meet the requirements of any of the foregoing grades shall be Off-Grade potatoes...

  5. 45 CFR 1630.2 - Definitions.

    Science.gov (United States)

    2010-10-01

    ... funds which Corporation management, the Office of Inspector General, the General Accounting Office, or... 45 Public Welfare 4 2010-10-01 2010-10-01 false Definitions. 1630.2 Section 1630.2 Public Welfare... § 1630.2 Definitions. (a) Allowed costs means a questioned cost that the Corporation, in a management...

  6. 45 CFR 1630.13 - Time.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 4 2010-10-01 2010-10-01 false Time. 1630.13 Section 1630.13 Public Welfare... § 1630.13 Time. (a) Computation. Time limits specified in this part shall be computed in accordance with... recipient's written request for good cause, grant an extension of time and shall so notify the recipient in...

  7. 18 CFR 157.8 - Acceptance for filing or rejection of applications.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Acceptance for filing or rejection of applications. 157.8 Section 157.8 Conservation of Power and Water Resources FEDERAL..., the Director of the Office of Energy Projects or the Director of the Office of Energy Market...

  8. 5 CFR 1630.14 - Appeals process.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Appeals process. 1630.14 Section 1630.14 Administrative Personnel FEDERAL RETIREMENT THRIFT INVESTMENT BOARD PRIVACY ACT REGULATIONS § 1630.14 Appeals process. (a) Within 20 work days of receiving the request for review, the Executive Director, after...

  9. 28 CFR 16.30 - Purpose and scope.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Purpose and scope. 16.30 Section 16.30 Judicial Administration DEPARTMENT OF JUSTICE PRODUCTION OR DISCLOSURE OF MATERIAL OR INFORMATION Production of FBI Identification Records in Response to Written Requests by Subjects Thereof § 16.30 Purpose...

  10. 40 CFR 63.1578 - Who implements and enforces this subpart?

    Science.gov (United States)

    2010-07-01

    ... National Emission Standards for Hazardous Air Pollutants for Petroleum Refineries: Catalytic Cracking Units, Catalytic Reforming Units, and Sulfur Recovery Units Other Requirements and Information § 63.1578 Who...

  11. 32 CFR 1630.46 - Class 4-T: Treaty alien.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 6 2010-07-01 2010-07-01 false Class 4-T: Treaty alien. 1630.46 Section 1630.46 National Defense Other Regulations Relating to National Defense SELECTIVE SERVICE SYSTEM CLASSIFICATION RULES § 1630.46 Class 4-T: Treaty alien. In Class 4-T shall be placed any registrant who is an alien who...

  12. NCBI nr-aa BLAST: CBRC-SARA-01-1578 [SEVENS

    Lifescience Database Archive (English)

    Full Text Available CBRC-SARA-01-1578 ref|NP_001077100.1| cOR52N9 olfactory receptor family 52 subfamily N-like [Canis lupus... familiaris] gb|ABO36681.1| 52N9 olfactory receptor protein [Canis lupus familiaris] NP_001077100.1 1e-146 78% ...

  13. Spatial heterodyne interferometry of VY Canis Majoris, alpha Orionis, alpha Scorpii, and R Leonis at 11 microns

    International Nuclear Information System (INIS)

    Sutton, E.C.; Storey, J.W.V.; Betz, A.L.; Townes, C.H.; Spears, D.L.

    1977-01-01

    Using the technique of heterodyne interferometry, measurements were made of the spatial distribution of 11 micron radiation from four late type stars. The circumstellar shells surrounding VY Canis Majoris, alpha Orionis, and alpha Scorpii were resolved, whereas that of R Leonis was only partially resolved at a fringe spacing of 0.4 sec

  14. Spatial heterodyne interferometry of VY Canis Major's, alpha Orionis, alpha Scorpii, and R leonis at 11 microns

    Science.gov (United States)

    Sutton, E. C.; Storey, J. W. V.; Betz, A. L.; Townes, C. H.; Spears, D. L.

    1977-01-01

    Using the technique of heterodyne interferometry, measurements were made of the spatial distribution of 11 micron radiation from four late type stars. The circumstellar shells surrounding VY Canis Majoris, alpha Orionis, and alpha Scorpii were resolved, whereas that of R Leonis was only partially resolved at a fringe spacing of 0.4 sec.

  15. 45 CFR 1630.12 - Applicability to derivative income.

    Science.gov (United States)

    2010-10-01

    ..., regulations, guidelines, and instructions, the Accounting Guide for LSC recipients, the terms and conditions... 45 Public Welfare 4 2010-10-01 2010-10-01 false Applicability to derivative income. 1630.12... CORPORATION COST STANDARDS AND PROCEDURES § 1630.12 Applicability to derivative income. (a) Derivative income...

  16. 21 CFR 862.1630 - Protein (fractionation) test system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Protein (fractionation) test system. 862.1630... Systems § 862.1630 Protein (fractionation) test system. (a) Identification. A protein (fractionation) test system is a device intended to measure protein fractions in blood, urine, cerebrospinal fluid, and other...

  17. Thermal analysis of the IDENT 1578 fuel pin shipping container

    International Nuclear Information System (INIS)

    Ingham, J.G.

    1980-01-01

    The IDENT 1578 container, which is a 110-in. long 5.5-in. OD tube, is designed for shipping FFTF fuel elements in T-3 casks between HEDL, HFEF, and other laboratories. The thermal analysis was conducted to evaluate whether or not the container satisfies its thermal design criteria

  18. Masses and K-line absolute magnitudes of γ Leonis and 35 Comae

    International Nuclear Information System (INIS)

    Deming, D.; Dykton, M.

    1979-01-01

    The visual binary system γ Leonis consists of two K giants whose total mass was found by Wilson to be less than 0.6M/sub sun/ when a distance was obtained from K-line absolute magnitudes of both components. Since the orbital period of the system is of order 600 years, the orbital solution has usually been regarded as the most likely explanation of the anomalous mass. We have investigated the uniqueness of the orbital solution. We find that the individual orbital elements are only poorly determined, but that a 3 /P 2 is known to within +- 10%. The anomalous mass of this binary system implies either extensive mass-loss or the need for revisions in the K-line absolute magnitudes. We also investigate the binary system 35 Comae. Wilson has noted that in this system the K-line absolute magnitude of the G8 III primary component implies a total mass of 8 M/sub sun/. However the A component of 35 Comae is not sufficiently luminous to justify such a large total mass. The system has a period of order 700 years, and the uniqueness of the orbital solution is therefore suspect. However, in this case also we have investigated the uniqueness of the orbital solution and find that individual orbital elements are poorly determined, but that a 3 /P 2 is known to within +- 17%. We point out that 35 Comae is known to be very metal rich, in contrast to γ Leonis which is metal poor. We conclude that a composition-dependent correction to the K-line absolute magnitudes provides the simplest explanation of these mass anomalies. Such a correction would also give better agreement with the trigonometric parallaxes of these binary systems

  19. 29 CFR 1630.15 - Defenses.

    Science.gov (United States)

    2010-07-01

    ... safety of the individual or others in the workplace. (See § 1630.2(r) defining direct threat.) (c) Other...) Conflict with other Federal laws. It may be a defense to a charge of discrimination under this part that a...

  20. 32 CFR 1630.43 - Class 4-D: Minister of religion.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 6 2010-07-01 2010-07-01 false Class 4-D: Minister of religion. 1630.43 Section... CLASSIFICATION RULES § 1630.43 Class 4-D: Minister of religion. In accord with part 1645 of this chapter any registrant shall be placed in Class 4-D who is a: (a) Duly ordained minister of religion; or (b) Regular...

  1. 32 CFR 1630.42 - Class 4-C: Alien or dual national.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 6 2010-07-01 2010-07-01 false Class 4-C: Alien or dual national. 1630.42... CLASSIFICATION RULES § 1630.42 Class 4-C: Alien or dual national. In Class 4-C shall be placed any registrant who... service in the United States. (b) Is an alien and who has departed from the United States prior to being...

  2. 12 CFR 16.30 - Request for interpretive advice or no-objection letter.

    Science.gov (United States)

    2010-01-01

    ... letter. 16.30 Section 16.30 Banks and Banking COMPTROLLER OF THE CURRENCY, DEPARTMENT OF THE TREASURY... of this part shall: (a) File a copy of the request, including any supporting attachments with the... describe the provisions of this part to which the request relates, the participants in the proposed...

  3. [Cii] emission from L1630 in the Orion B molecular cloud.

    Science.gov (United States)

    Pabst, C H M; Goicoechea, J R; Teyssier, D; Berné, O; Ochsendorf, B B; Wolfire, M G; Higgins, R D; Riquelme, D; Risacher, C; Pety, J; Le Petit, F; Roueff, E; Bron, E; Tielens, A G G M

    2017-10-01

    L1630 in the Orion B molecular cloud, which includes the iconic Horsehead Nebula, illuminated by the star system σ Ori, is an example of a photodissociation region (PDR). In PDRs, stellar radiation impinges on the surface of dense material, often a molecular cloud, thereby inducing a complex network of chemical reactions and physical processes. Observations toward L1630 allow us to study the interplay between stellar radiation and a molecular cloud under relatively benign conditions, that is, intermediate densities and an intermediate UV radiation field. Contrary to the well-studied Orion Molecular Cloud 1 (OMC1), which hosts much harsher conditions, L1630 has little star formation. Our goal is to relate the [Cii] fine-structure line emission to the physical conditions predominant in L1630 and compare it to studies of OMC1. The [Cii] 158 μ m line emission of L1630 around the Horsehead Nebula, an area of 12' × 17', was observed using the upgraded German Receiver for Astronomy at Terahertz Frequencies (upGREAT) onboard the Stratospheric Observatory for Infrared Astronomy (SOFIA). Of the [Cii] emission from the mapped area 95%, 13 L ⊙ , originates from the molecular cloud; the adjacent Hii region contributes only 5%, that is, 1 L ⊙ . From comparison with other data (CO(1-0)-line emission, far-infrared (FIR) continuum studies, emission from polycyclic aromatic hydrocarbons (PAHs)), we infer a gas density of the molecular cloud of n H ∼ 3 · 10 3 cm -3 , with surface layers, including the Horsehead Nebula, having a density of up to n H ∼ 4 · 10 4 cm -3 . The temperature of the surface gas is T ∼ 100 K. The average [Cii] cooling efficiency within the molecular cloud is 1.3 · 10 -2 . The fraction of the mass of the molecular cloud within the studied area that is traced by [Cii] is only 8%. Our PDR models are able to reproduce the FIR-[Cii] correlations and also the CO(1-0)-[Cii] correlations. Finally, we compare our results on the heating efficiency of the

  4. Evolution of the 1984 outburst of the transient X-ray source 4U 1630 - 47

    International Nuclear Information System (INIS)

    Parmar, A.N.; Stella, L.; White, N.E.

    1986-01-01

    The results of a series of EXOSAT observations of the X-ray transient 4U 1630 - 47 during an outburst in 1984 are presented. The source decayed over an interval of about 100 days from a maximum 1-50 keV luminosity of about 2.8 x 10 to the 38th to about 4 x 10 to the 36th erg/s (for an assumed distance of 10 kpc). The 1-50 keV spectrum was best represented by a soft Wien-like spectrum with a temperature about 1 keV and a high-energy power-law tail. The relative contribution of the soft component to that of the high-energy power law decreased by atleast a factor of about 2 as the overall luminosity decreased. When the source was at its maximum observed luminosity, short time scale 7 percent intensity variations (1-7 keV) were seen with a characteristic time scale of about 20 s. The shortest time scale variability detected was about 50 ms. A 10-arcsec position obtained using an imaging telescope excludes a previously suggested optical counterpart. The spectral properties of 4U 1630 - 47 are reminiscent of those of the black hole candidate Cyg X-1 when it evolves from a high to a low state. 28 references

  5. 32 CFR 1630.48 - Class 4-A-A: Registrant who has performed military service for a foreign nation.

    Science.gov (United States)

    2010-07-01

    ... military service for a foreign nation. 1630.48 Section 1630.48 National Defense Other Regulations Relating... who has performed military service for a foreign nation. In Class 4-A-A shall be placed any registrant... be written in the English language. [52 FR 24456, July 1, 1987] ...

  6. Work plan for the radiological survey for the David Witherspoon, Incorporated, Landfill-1630 site, Knoxville, Tennessee

    International Nuclear Information System (INIS)

    1996-07-01

    This work plan establishes the methods and requirements for performing a radiological survey at the David Witherspoon, Incorporated, Landfill-1630 Site, Knoxville, Tennessee (DWI 1630 Site) in accordance with requirements under the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). The radiological survey will identify the radiological contamination level of the equipment and debris stored at the DWI 1630 Site. The data generated from the survey activities will support the decisions for characterization of the equipment/debris and aid in subsequent disposition and waste handling. The survey activities to be performed under this work plan include an equipment radiological survey, a walkover survey, and an immunoassay testing for polychlorinated biphenyls (PCBs). This work plan includes a quality assurance (QA)/quality control (QC) project plan, a health and safety (H ampersand S) plan, and a waste management plan

  7. 45 CFR 1630.11 - Applicability to non-LSC funds.

    Science.gov (United States)

    2010-10-01

    ... an activity prohibited by or inconsistent with section 504, as defined by 45 CFR 1610.2(b), may be... purpose prohibited by the LSC Act, as defined by 45 CFR 1610.2(a), may be charged to private funds, except... provided. (b) According to the review and appeal procedures of 45 CFR 1630.7, the Corporation may recover...

  8. Hard X-ray detection of the black hole candidates 4U 1630-47 and IGR J17091-3624 up to 200 keV with INTEGRAL

    DEFF Research Database (Denmark)

    Bodaghee, A.; Kuulkers, E.; Tomsick, J. A.

    2012-01-01

    During monitoring observations of the Norma and Inner Perseus Arms (rev. 1209: 2012 Sept. 6 from 18:18:23 to 22:00:21 UTC), INTEGRAL-ISGRI revealed that the accreting black hole candidates 4U 1630-47 and IGR J17091-3624 have brightened in the hard X-rays. Mosaic images consisting of 12.6 ks worth...

  9. 5 CFR 1630.11 - Requirements for requests to amend records.

    Science.gov (United States)

    2010-01-01

    ..., investment allocation, interfund transfers, loans, loan repayments, and withdrawals Write to TSP record..., retirement code, address, loan repayments, the amount of participant's contribution, amount of the Government... listed in § 1630.4. The words “Privacy Act—Request to Amend Record” should be written on the letter and...

  10. 29 CFR 1630.7 - Standards, criteria, or methods of administration.

    Science.gov (United States)

    2010-07-01

    ... Standards, criteria, or methods of administration. It is unlawful for a covered entity to use standards, criteria, or methods of administration, which are not job-related and consistent with business necessity... 29 Labor 4 2010-07-01 2010-07-01 false Standards, criteria, or methods of administration. 1630.7...

  11. America's Puritan Press, 1630-1690: The Value of Free Expression.

    Science.gov (United States)

    WIlliams, Julie Hedgepeth

    During the period from 1630 to 1690, the Puritans were not arbitrary oppressors of free speech. They believed that public expression was valuable and necessary. They restricted only ungodly print or speeches by heretics and blasphemers. Within the boundaries of godly expression, Puritans encouraged discussion for the better enlightenment of…

  12. Arsenic-related skin lesions and glutathione S-transferase P1 A1578G (lle105Val) polymorphism in two ethnic clans exposed to indoor combustion of high arsenic coal in one village

    Energy Technology Data Exchange (ETDEWEB)

    Lin, G.F.; Du, H.; Chen, J.G.; Lu, H.C.; Guo, W.C.; Meng, H.; Zhang, T.B.; Zhang, X.J.; Lu, D.R.; Golka, K.; Shen, J.H. [Chinese Academy of Sciences, Shanghai (China)

    2006-12-15

    A total of 2402 patients with arsenic-related skin lesions, such as hyperkeratosis, hyperpigmentation or hypopigmentation, or even skin cancer in a few villages in Southwest Guizhou Autonomous Prefecture, China represent a unique case of endemic arsenism related with indoor combustion of high arsenic coal. This study aimed to investigate the cluster of arsenism cases and the possible relevant factors including GSTP1 polymorphism in two clans of different ethnic origin living in one village for generations. Arsenism morbidity in Miao clan P was significantly lower than in the neighbouring Han clan G1 (5.9 vs. 32.7%, odds ratio (OR)=0.13, 95% confidence interval (CI): 0.06-0.27, P < 0.0001). No sex differences were confirmed inside both clans. Analyses of the environmental samples indicated that Miao clan P members were exposed to higher amounts of arsenic via inhalation and food ingestion. Hair and urine samples also proved a higher arsenic body burden in ethnic Miao individuals. No corresponding differences by sex were found. Higher frequencies of combined mutant genotype G/G1578 and A/G1578 (OR=4.72, 95% CI: 2.34-9.54, P < 0.0001) and of mutant allele G1578 (OR=3.22, 95% CI: 2.00-5.18, P < 0.0001) were detected in diagnosed arsenism patients than in non-diseased individuals. The Miao individuals showed a lower percentage of combined mutant genotypes (30.6 vs. 52.7%, OR=0.40, 95% CI: 0.19-0.84, P=0.015) as well as of mutant allele G1578 (OR=0.46, 95% CI: 0.24-0.88, P=0.017) than their Han neighbours. Conclusions Genetic predisposition influences dermal arsenism toxicity. The GSTP1 A1578G (IIe105Val) status might be a susceptibility factor for arsenic-related skin lesions.

  13. AD Leonis: Radial Velocity Signal of Stellar Rotation or Spin–Orbit Resonance?

    Science.gov (United States)

    Tuomi, Mikko; Jones, Hugh R. A.; Barnes, John R.; Anglada-Escudé, Guillem; Butler, R. Paul; Kiraga, Marcin; Vogt, Steven S.

    2018-05-01

    AD Leonis is a nearby magnetically active M dwarf. We find Doppler variability with a period of 2.23 days, as well as photometric signals: (1) a short-period signal, which is similar to the radial velocity signal, albeit with considerable variability; and (2) a long-term activity cycle of 4070 ± 120 days. We examine the short-term photometric signal in the available All-Sky Automated Survey and Microvariability and Oscillations of STars (MOST) photometry and find that the signal is not consistently present and varies considerably as a function of time. This signal undergoes a phase change of roughly 0.8 rad when considering the first and second halves of the MOST data set, which are separated in median time by 3.38 days. In contrast, the Doppler signal is stable in the combined High-Accuracy Radial velocity Planet Searcher and High Resolution Echelle Spectrometer radial velocities for over 4700 days and does not appear to vary in time in amplitude, phase, period, or as a function of extracted wavelength. We consider a variety of starspot scenarios and find it challenging to simultaneously explain the rapidly varying photometric signal and the stable radial velocity signal as being caused by starspots corotating on the stellar surface. This suggests that the origin of the Doppler periodicity might be the gravitational tug of a planet orbiting the star in spin–orbit resonance. For such a scenario and no spin–orbit misalignment, the measured v\\sin i indicates an inclination angle of 15.°5 ± 2.°5 and a planetary companion mass of 0.237 ± 0.047 M Jup.

  14. Findings of the wetland survey of the David Witherspoon, Inc., 1630 Site, South Knoxville, Knox County, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Rosensteel, B.A. [JAYCOR Environmental, Oak Ridge, TN (United States)

    1997-03-01

    In accordance with Department of Energy (DOE) Regulations surveys for wetland presence or absence were conducted in September 1996 on the DWI-1630 site (Witherspoon Landfill) located in South Knoxville, Knox County, Tennessee. The DWI-1630 site includes a closed, capped landfill area, areas of past disturbance adjacent to the capped area, and patches of hardwood forest. Wetlands were identified on the landfill cap and in a small bottomland that was formerly used for a retention pond in the southwest corner of the DWI-1630 site. The wetlands identified on the cap are man-induced, atypical situation wetlands. These areas have hydrophytic vegetation and wetland hydrology, but the soils do not have hydric characteristics. Wetland development appears to be due to a combination of the grading or subsidence of the clay landfill cap, the low permeability of the clay fill soil, and the absence of surface drainage outlets from the depressions. These atypical situation wetland areas may not be considered by the US Army Corps of Engineers or the State of Tennessee to be jurisdictional wetlands. The wetland in the former retention pond area has hydrophytic vegetation, wetland hydrology, and hydric soils and is a jurisdictional wetland.

  15. RXTE Observation of 4U 1630-47 During its 1998 Outburst

    Science.gov (United States)

    Dieters, Stefan W.

    1999-01-01

    During the 1998 outburst of 4U 1630-47 it was extensively observed with the Rossi X-ray Timing Explorer (RXTE). In order to cover the outburst more thoroughly our data (Obs. ID: 30178-0[1-2]- ) were combined with those of Cui et al. (Obs. ID: 30188-02-). These observations were later compared with the complementary observations. Power density and energy spectra have been made for each observation. The data was used to place radio and hard X-ray observations within context. Analysis of SAX (Satellite per Astronomia a raggi X) and BATSE (Burst and Transient Source Experiment) data was also included within the study. The count rate and position in hardness-intensity, color-color diagrams and simple spectral fits are used to track the concurrent spectral changes. The source showed seven distinct types of timing behavior, most of which show differences with the canonical black hole spectral/timing states. In marked contrast to previous outbursts, we find quasi-periodic oscillation (QPO) signals during nearly all stages of the outburst with frequencies between 0.06 Hz and 14 Hz and a remarkable variety of other characteristics. In particular we find large (up to 23% rms) amplitude QPO on the early rise. Later, slow 0.1 Hz semi- regular short (- 5 sec), 9 to 16% deep dips dominate the light curve. At this time there are two QPOS, one stable near 13.5 Hz and the other whose frequency drops from 6-8 Hz to - 4.5 Hz during the dips. BeppoSAX observations during the very late declining phase show 4U 1630-47 in a low state. These results will shortly be published. We are completing a detailed analysis of the energy spectra (in preparation). The QPO/noise properties are being correlated with the concurrent spectral changes. Detailed studies of the QPO are being undertaken using sophisticated timing analysis methods. Finally a comparison with the other outbursts of 1630-47 is being made.

  16. 5 CFR 1630.9 - Access to the history (accounting) of disclosures from records.

    Science.gov (United States)

    2010-01-01

    ... BOARD PRIVACY ACT REGULATIONS § 1630.9 Access to the history (accounting) of disclosures from records. Rules governing access to the accounting of disclosures are the same as those for granting access to the... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Access to the history (accounting) of...

  17. Black Hole Mass Determination In the X-Ray Binary 4U 1630-47: Scaling of Spectral and Variability Characteristics

    Science.gov (United States)

    Seifina, Elena; Titarchuk, Lev; Shaposhnikov, Nikolai

    2014-01-01

    We present the results of a comprehensive investigation on the evolution of spectral and timing properties of the Galactic black hole candidate 4U 1630-47 during its spectral transitions. In particular, we show how a scaling of the correlation of the photon index of the Comptonized spectral component gamma with low-frequency quasi-periodic oscillations (QPOs), ?(sub L), and mass accretion rate, M, can be applied to the black hole mass and the inclination angle estimates.We analyze the transition episodes observed with the Rossi X-Ray Timing Explorer and BeppoSAX satellites.We find that the broadband X-ray energy spectra of 4U 1630-47 during all spectral states can be modeled by a combination of a thermal component, a Comptonized component, and a red-skewed iron-line component. We also establish that gamma monotonically increases during transition from the low-hard state to the high-soft state and then saturates for high mass accretion rates. The index saturation levels vary for different transition episodes. Correlations of gamma versus ?(sub L) also show saturation at gamma (is) approximately 3. Gamma -M and gamma -?(sub L) correlations with their index saturation revealed in 4U 1630-47 are similar to those established in a number of other black hole candidates and can be considered as an observational evidence for the presence of a black hole in these sources. The scaling technique, which relies on XTE J1550-564, GRO 1655-40, and H1743-322 as reference sources, allows us to evaluate a black hole mass in 4U 1630-47 yielding M(sub BH) (is) approximately 10 +/- 0.1 solar masses and to constrain the inclination angle of i (is) approximately less than 70 deg.

  18. A delayed transition to the hard state for 4U 1630-47 at the end of its 2010 outburst

    Energy Technology Data Exchange (ETDEWEB)

    Tomsick, John A. [Space Sciences Laboratory, 7 Gauss Way, University of California, Berkeley, CA 94720-7450 (United States); Yamaoka, Kazutaka [Solar-Terrestrial Environment Laboratory, Department of Particles and Astronomy, Nagoya University, Furocho, Chikusa-ku, Nagoya, Aichi 464-8601 (Japan); Corbel, Stephane [AIM - Unité Mixte de Recherche CEA - CNRS - Université Paris VII - UMR 7158, CEA-Saclay, Service d' Astrophysique, F-91191 Gif-sur-Yvette Cedex (France); Kalemci, Emrah [Sabanci University, Orhanli-Tuzla, Istanbul 34956 (Turkey); Migliari, Simone [Department d' Astronomia i Meteorologia, Universitat de Barcelona, Marti I Franques 1, E-08028 Barcelona (Spain); Kaaret, Philip, E-mail: jtomsick@ssl.berkeley.edu [Department of Physics and Astronomy, University of Iowa, Van Allen Hall, Iowa City, IA 52242 (United States)

    2014-08-10

    Here we report on Swift and Suzaku observations near the end of an outburst from the black hole transient 4U 1630-47 and Chandra observations when the source was in quiescence. 4U 1630-47 made a transition from a soft state to the hard state ∼50 days after the main outburst ended. During this unusual delay, the flux continued to drop, and one Swift measurement found the source with a soft spectrum at a 2-10 keV luminosity of L = 1.07 × 10{sup 35} erg s{sup –1} for an estimated distance of 10 kpc. While such transients usually make a transition to the hard state at L/L{sub Edd} = 0.3%-3%, where L{sub Edd} is the Eddington luminosity, the 4U 1630-47 spectrum remained soft at L/L{sub Edd} = 0.008 M{sub 10}{sup −1}% (as measured in the 2-10 keV band), where M{sub 10} is the mass of the black hole in units of 10 M{sub ☉}. An estimate of the luminosity in the broader 0.5-200 keV bandpass gives L/L{sub Edd} = 0.03 M{sub 10}{sup −1}%, which is still an order of magnitude lower than typical. We also measured an exponential decay of the X-ray flux in the hard state with an e-folding time of 3.39 ± 0.06 days, which is much less than previous measurements of 12-15 days during decays by 4U 1630-47 in the soft state. With the ∼100 ks Suzaku observation, we do not see evidence for a reflection component, and the 90% confidence limits on the equivalent width of a narrow iron Kα emission line are <40 eV for a narrow line and <100 eV for a line of any width, which is consistent with a change of geometry (either a truncated accretion disk or a change in the location of the hard X-ray source) in the hard state. Finally, we report a 0.5-8 keV luminosity upper limit of <2 × 10{sup 32} erg s{sup –1} in quiescence, which is the lowest value measured for 4U 1630-47 to date.

  19. From Point Cloud to Digital Fabrication: a Tangible Reconstruction of Ca' Venier Dei Leoni, the Guggenheim Museum in Venice

    Science.gov (United States)

    Balletti, C.; D'Agnano, F.; Guerra, F.; Vernier, P.

    2016-06-01

    The paper describes how new digital methodologies can be used within the field of Cultural Heritage, not only with the aim of documenting the actual state of an architecture but to review the past transformations it has undergone, conserving and representing these histories as well. The premise to conservation and enhancement of our Heritage is a deep study in terms of position, shape, colour, and also of the historical and artistic features. Survey methods have acquired data acquisition techniques in line with technological progress: today's electronic and IT technologies, that are the tools of modern Geomatics, allow the effective survey and representation of 3D objects, from architectural structures to sculptures or archaeological finds. Over the last few years, the methodologies of acquisition and integrated representation for 3D patrimony documentation have developed and consolidated considerably: the possibilities of the digital realm can augment the understanding and the valorisation of a monument. The specific case offered in the present paper, Ca' Venier dei Leoni, the palace where is the Guggenheim Museum in Venice, is a significant example. It suggests not only the theme of the "no longer existing", or better never built, but also the opportunity to formulate hypotheses regarding its implementation and the impact that the palace would have had in the Venetian contest.

  20. The X-ray spectra of the black hole candidate 4U 1630-47 during its 2012 outburst

    NARCIS (Netherlands)

    Wang, Y.; Mendez, M.

    2015-01-01

    Diaz Trigo et al. (2013) reported the detection of three Doppler-shifted emission lines arising from baryonic matter in the jet of 4U 1630-47 during its 2012 outburst. Here we propose an alternative model that, without the need of the lines from the jet, and with less free parameters, fits the same

  1. Iang evangelivm Ul-Kadus menjurat kapada Marcum : The first Malay gospel of mark (1629-1630) and the Agama Kumpeni

    NARCIS (Netherlands)

    De Vries, Lourens

    The topic of this article is the Malay gospel of Mark of 1629-1630 that was recently discovered in the library of Lincoln Cathedral in England, a gospel translated by Albert Corneliszoon Ruyl, employee of the voc. Ruyl's gospels of Matthew and Mark are the earliest attested Bible translations in

  2. Force Characteristics in the Submerged and Planing Condition of a 1/5.78-Scale Model of a Hydro-Ski-Wheel Combination for the Grumman JRF-5 Airplane. TED No. NACA DE 357

    Science.gov (United States)

    Land, Norman S.; Pelz, Charles A.

    1952-01-01

    Force characteristics determined from tank tests of a 1/5.78 scale model of a hydro-ski-wheel combination for the Grumman JRF-5 airplane are presented. The model was tested in both the submerged and planing conditions over a range of trim, speed, and load sufficiently large to represent the most probable full-size conditions.

  3. Changes in the Cloud Belts of Jupiter, 1630–1664, as Reported in the 1665 Astronomia Reformata of Giovanni Battista Riccioli

    Directory of Open Access Journals (Sweden)

    Graney Christopher M.

    2010-12-01

    Full Text Available A translation of a section from the 1665 Astronomia Reformata of G. B. Riccioli discussing the appearance of the disk of Jupiter during the years 1630-1664; changes in the Jovian cloud belts as recorded by a variety of observers are a major feature of Riccioli’s discussion.

  4. Radio and X-Ray Observations of the 1998 Outburst of the Recurrent X-Ray Transient 4U 1630-47

    Science.gov (United States)

    Hjellming, R. M.; Rupen, M. P.; Mioduszewski, A. J.; Kuulkers, E.; McCollough, M.; Harmon, B. A.; Buxton, M.; Sood, R.; Tzioumis, A.; Rayner, D.; Dieters, S.; Durouchoux, P.

    1999-03-01

    We report radio (NRAO VLA and Australia Telescope Compact Array), soft X-ray (Rossi X-Ray Timing Explorer ASM), and hard X-ray (Compton Gamma Ray Observatory BATSE) observations of a 1998 outburst in the recurring X-ray transient 4U 1630-47, where radio emission was detected for the first time. The radio observations identify the position of 4U 1630-47 to within 1". Because the radio emission is optically thin with a spectral index of ~-0.8 during the rise, peak, and decay of the initial radio event, the emission is probably coming from an optically thin radio jet ejected over a period of time. The 20-100 keV emission first appeared 1998 January 28 (MJD 50841), the 2-12 keV emission first appeared 1998 February 3 (MJD 50847), and the first radio emission was detected 1998 February 12.6 (MJD 50856.6). The rise of the radio emission probably began about 1998 February 7 (MJD 50851) when the X-rays were in a very hard fluctuating-hardness state, just before changing to a softer, more stable hardness state.

  5. A Link Between X-ray Emission Lines and Radio Jets in 4U 1630-47?

    Science.gov (United States)

    Neilsen, Joseph; Coriat, Mickaël; Fender, Rob; Lee, Julia C.; Ponti, Gabriele; Tzioumis, A.; Edwards, Phillip; Broderick, Jess

    2014-06-01

    Recently, Díaz Trigo et al. reported an XMM-Newton detection of relativistically Doppler-shifted emission lines associated with steep-spectrum radio emission in the stellar-mass black hole candidate 4U 1630-47 during its 2012 outburst. They interpreted these lines as indicative of a baryonic jet launched by the accretion disk. We present a search for the same lines earlier in the same outburst using high-resolution X-ray spectra from the Chandra HETGS. While our observations (eight months prior to the XMM-Newton campaign) also coincide with detections of steep spectrum radio emission by the Australia Telescope Compact Array, we find a strong disk wind but no evidence for any relativistic X-ray emission lines. Indeed, despite ˜5× brighter radio emission, our Chandra spectra allow us to place an upper limit on the flux in the blueshifted Fe XXVI line that is ˜20× weaker than the line observed by Díaz Trigo et al. Thus we can conclusively say that radio emission is not universally associated with relativistically Doppler-shifted emission lines in 4U 1630-47. We explore several scenarios that could explain our differing results, including variations in the geometry of the jet or a mass-loading process or jet baryon content that evolves with the accretion state of the black hole. We also consider the possibility that the radio emission arises in an interaction between a jet and the nearby ISM, in which case the X-ray emission lines might be unrelated to the radio emission.

  6. Probing disk wind and other properties of 4U 1630-47

    Science.gov (United States)

    Bhattacharyya, Sudip

    2015-09-01

    The accreting Galactic black hole transient 4U 1630-47, which is currently in outburst, is an ideal source to probe two types of accreted matter ejection: (1) via disk wind and (2) via jet, both using the observed narrow spectral lines (Diaz Trigo et al., 2013, Nature, 504, 206; Neilsen et al. 2014; Diaz Trigo et al. 2014). Chandra gratings are ideal to study such lines. The source also showed indications of high-frequency (HF) quasi-periodic oscillations (QPOs) in a rather high (150-450 Hz) frequency range, which can be extremely useful to probe the strong gravity regime. The AstroSat satellite, because of its large area and high timing resolution in a broad energy band, can potentially detect and measure HF QPOs and probe the source broadband spectrum and state. Hence, our proposed 30 ks Chandra exposure, nearly contemporaneous with complementary AstroSat observations, will provide an excellent way to probe the accretion and ejection mechanism in the strong gravity regime.

  7. Chandra Takes on Heavy Jets and Massive Winds in 4U 1630-47

    Science.gov (United States)

    Neilsen, Joey

    2014-11-01

    Recently, Díaz Trigo et al. reported the discovery of relativistic baryons in a jet in XMM/ATCA observations of the 2012 outburst of the black hole 4U 1630-47. We present a search for a similarly massive jet earlier in the same outburst using high-resolution X-ray spectra from the Chandra HETGS. Despite a detection of radio emission with ATCA, we find no evidence of a heavy jet in the X-ray spectrum, with tight upper limits on the relativistic emission lines seen by Díaz Trigo eight months later. Instead, we find deep absorption lines from a massive, highly ionized disk wind, whose properties can be probed with detailed photoionization models. We explore several scenarios to explain the two modes of massive outflow in this remarkable black hole system.

  8. Restauro storico y sacrae imagines en Évora bajo el gobierno del arzobispo don Teotonio de Braganza (1578-1602

    Directory of Open Access Journals (Sweden)

    Serrão, Vitor

    2016-06-01

    Full Text Available This essay focuses on the figure of D. Teotónio de Bragança, the Archbishop of Évora between 1578 and 1602, showing the importance of his building projects and artistic decorations, under the sign of Tridentine values. He adapted the principles of ‘restauro storico’ and the revitalization of ‘imagine sacrae’ in the Early Christian sanctuaries of his archdiocese. He promoted a new type of sacred architecture using artists formed in Rome, such as the architect and sculptor Pero Vaz Pereira. The art born in Évora in the late-16th century, under the sign of the Contra-Maniera, achieves a quality that rivals with that of the reign of King John III and the humanist André de Resende. Old cults and new iconographic themes emerge with D. Teotónio, such as SS. Manços, Jordão, Comba and other martyrs considered Évora-born. He ordered several works for Madrid, Rome and Florence to enrich the Cathedral and the Carthusian Monastery founded by him. Thus this period forms one of the most remarkable chapters in Portuguese Tridentine art and deserves to be properly analyzed.En este ensayo se aborda la figura de don Teotonio de Braganza (arzobispo de Évora entre 1578 y 1602 y su legado en los programas de decoración artística y en el modo como adaptó los principios tridentinos del restauro storico y la revitalización de las sacra imagines en lugares de culto paleocristiano de su archidiócesis. Durante su munus se desarrolló un nuevo tipo de arquitectura sacra gracias a la participación de artistas con formación romana, como era el caso del arquitecto y escultor Pero Vaz Pereira. El arte que vio la luz en Évora a finales del siglo XVI, bajo el signo de la Contramaniera, alcanzó un esplendor que rivalizaría con el del reinado de Juan III y del humanista André de Resende. Con don Teotonio emergen nuevos temas y cultos, como los de los santos Mancio, Jordán, Comba y otros mártires considerados ‘eborenses’. El arzobispo encarg

  9. Three days in October of 1630: detailed examination of mortality during an early modern plague epidemic in Venice.

    Science.gov (United States)

    Ell, S R

    1989-01-01

    The epidemiology of medieval and early modern European plague remains highly controversial. It now seems likely that the epidemiology was not uniform throughout either the geographic or temporal boundaries of the plague in Western Europe. The Venetian plague of 1630 was extensively documented; day-by-day records were kept, and each mortality in the city was recorded in a set format. The days 23-25 October 1630, representing a period when mortality was beginning to increase sharply, are examined. In all, 1,163 deaths were recorded. They show a large preponderance of women; a mean age of 28, but a majority of cases clumped between ages 0 and 25 years; and an unequal sex ratio among children. Further, there was an identifiable smallpox epidemic raging simultaneously with plague, and more than one-quarter of all the deaths in this period of high mortality were clearly due to nonplague causes. Deaths due to wounds and associated with violence were prominent in one parish, which suggests that in times of plague the breakdown in the normal machinery of government, in everyday patterns of life, and possibly of mental well being resulted in an even more exaggerated death toll. These factors--violence, accidents, and other epidemics--have never been so definitively tied to a European plague epidemic. In addition, there are hints that plague has a marked proclivity to kill pregnant women--their deaths far outnumber those anticipated--and that plague was very localized at a given moment within Venice itself, even during times of peak mortality.

  10. On A Recent Theory of 'Legal Obligation'

    Directory of Open Access Journals (Sweden)

    Bruno Leoni

    2009-02-01

    Full Text Available This paper, by the late Bruno Leoni, was originally published in the Italian journal Il Politico in 1966. In the article, Leoni reviews H.L.A. Hart’s The Concept of Law (1961. Hart first analyzes the concept of law by resorting to the classical concept of “obligation.” But he later tries a “fresh start” by resorting to the concept of “secondary rules.” In his review, Leoni argues that the former attempt is confronted with serious difficulties, and that the latter attempt (to which professor Hart possibly resorts in view of overcoming some of said difficulties is ultimately inconsistent with the former

  11. Cine MR imaging assessment of regional left ventricular systolic wall thickening in patients with remote myocardial infarction

    International Nuclear Information System (INIS)

    Pfugfelder, P.; White, R.D.; Sechtem, U.; Gould, R.G.; Higgins, C.B.

    1986-01-01

    Cine MR imaging, a new rapid imaging technique, was used to acquire transverse images of the heart at a rate of 16-30 frames per cardiac cycle. Left ventricular wall thickness was measured at end diastole and end systole in six regions in the midventricular section of 13 healthy subjects and seven patients with previously documented myocardial infarction. Mean percent systolic wall thickening (%SWT) was 51% +- 26% in healthy subjects. In patients, %SWT was -8% +- 22% in the infarct zone and 42% +- 22% in the normal myocardium. In addition to the qualitative information derived from the cinematic display, determination of regional %SWT by cine-MR imaging may be useful for quantifying regional left ventricular dysfunction

  12. Henry S. Turner, The English Renaissance Stage. Geometry, Poetics, and the Practical Spatial Arts 1580-1630 - Tim Fitzpatrick, Playwright, Space and Place in Early Modern Performance

    Directory of Open Access Journals (Sweden)

    Luigi Giuliani

    2013-05-01

    Full Text Available Review of Henry S. Turner, The English Renaissance Stage. Geometry, Poetics, and the Practical Spatial Arts 1580-1630, Oxford University Press, Oxford, 2006, reimpr. 2010, 326 pp. ISBN: 978-0-19-959545-7 y Tim Fitzpatrick, Playwright, Space and Place in Early Modern Performance, Ashgate, Franham, 2011, 314 pp. ISBN: 978-1-4094-2827-5.

  13. The disk wind in the rapidly spinning stellar-mass black hole 4U 1630-472 observed with NuSTAR

    DEFF Research Database (Denmark)

    King, Ashley L.; Walton, Dominic J.; Miller, Jon M.

    2014-01-01

    We present an analysis of a short NuSTAR observation of the stellar-mass black hole and low-mass X-ray binary 4U 1630-472. Reflection from the inner accretion disk is clearly detected for the first time in this source, owing to the sensitivity of NuSTAR. With fits to the reflection spectrum, we...... find evidence for a rapidly spinning black hole, (1σ statistical errors). However, archival data show that the source has relatively low radio luminosity. Recently claimed relationships between jet power and black hole spin would predict either a lower spin or a higher peak radio luminosity. We also...

  14. Reproducibility of 201Tl myocardial imaging

    International Nuclear Information System (INIS)

    McLaughlin, P.R.; Martin, R.P.; Doherty, P.; Daspit, S.; Goris, M.; Haskell, W.; Lewis, S.; Kriss, J.P.; Harrison, D.C.

    1977-01-01

    Seventy-six thallium-201 myocardial perfusion studies were performed on twenty-five patients to assess their reproducibility and the effect of varying the level of exercise on the results of imaging. Each patient had a thallium-201 study at rest. Fourteen patients had studies on two occasions at maximum exercise, and twelve patients had studies both at light and at maximum exercise. Of 70 segments in the 14 patients assessed on each of two maximum exercise tests, 64 (91 percent) were reproducible. Only 53 percent (16/30) of the ischemic defects present at maximum exercise were seen in the light exercise study in the 12 patients assessed at two levels of exercise. Correlation of perfusion defects with arteriographically proven significant coronary stenosis was good for the left anterior descending and right coronary arteries, but not as good for circumflex artery disease. Thallium-201 myocardial imaging at maximum exercise is reproducible within acceptable limits, but careful attention to exercise technique is essential for valid comparative studies

  15. Poesía e historia en el Compendio Historial (1630 de Melchor Jufré de Águila

    Directory of Open Access Journals (Sweden)

    Julio Sebastián Figueroa

    2016-12-01

    Full Text Available En este artículo analizo el cruce entre poesía e historia en el Compendio Historial del Descubrimiento y Conquista del Reino de Chile (1630 de Melchor Jufré de Águila. Para este fin, describo primero la trayectoria material del libro con el propósito de distinguir prácticas de escritura y publicación asociadas a determinados órdenes del discurso. Enseguida, discuto los diferentes modelos historiográficos y poéticos que atraviesan el texto, considerando la tradición humanista de la crónica abreviada y la sustitución de la épica por la poesía gongorista como modelo de representación de la conquista a principios del siglo XVII. Finalmente, analizo la crítica de Jufré de Águila a la guerra defensiva, así como la controversia que mantuvo con el misionero jesuita Luis de Valdivia, para demostrar uno de los conflictos discursivos que se sostuvieron en el naciente orden letrado del Chile colonial.

  16. Baryons in the relativistic jets of the stellar-mass black-hole candidate 4U 1630-47.

    Science.gov (United States)

    Trigo, María Díaz; Miller-Jones, James C A; Migliari, Simone; Broderick, Jess W; Tzioumis, Tasso

    2013-12-12

    Accreting black holes are known to power relativistic jets, both in stellar-mass binary systems and at the centres of galaxies. The power carried away by the jets, and, hence, the feedback they provide to their surroundings, depends strongly on their composition. Jets containing a baryonic component should carry significantly more energy than electron-positron jets. Energetic considerations and circular-polarization measurements have provided conflicting circumstantial evidence for the presence or absence of baryons in jets, and the only system in which they have been unequivocally detected is the peculiar X-ray binary SS 433 (refs 4, 5). Here we report the detection of Doppler-shifted X-ray emission lines from a more typical black-hole candidate X-ray binary, 4U 1630-47, coincident with the reappearance of radio emission from the jets of the source. We argue that these lines arise from baryonic matter in a jet travelling at approximately two-thirds the speed of light, thereby establishing the presence of baryons in the jet. Such baryonic jets are more likely to be powered by the accretion disk than by the spin of the black hole, and if the baryons can be accelerated to relativistic speeds, the jets should be strong sources of γ-rays and neutrino emission.

  17. Les rouages économiques d'une société minière: échanges et crédit. Loja, 1550-1630

    Directory of Open Access Journals (Sweden)

    1984-01-01

    Full Text Available Le Sud de l'Audience de Quito a joui, depuis la fondation de Loja en 1546, jusqu'au déclin des mines vers 1630, d'une prospérité économique due à l'intensité des échanges commerciaux entre la Nouvelle Grenade et le Pérou, mais surtout à l'existence d'un vaste marché de consommation pour satisfaire les besoins des centres miniers. L'abondance d'une monnaie -l'or extrait des mines locales- a nourri de nombreuses transactions et permis les investissements dans le commerce, l'agriculture et l'élevage. C'est en utilisant les contrats de rentes (censos établis par le couvent de religieuses de Loja, que l'auteur a examiné le fonctionnement du crédit dans la société coloniale et la vitalité de la circulation des capitaux. Cette analyse permet de mettre à jour l'ambiguïté de ce système financier très développé dans l'Amérique coloniale: au XVIème siècle il renforce la prospérité d'une économie locale qui compte de nombreux atouts, mais dès le XVIIème, aggrave les difficultés économiques en devenant une charge supplémentaire. Desde la fundación de Loja en 1546 hasta la decadencia de las minas hacia 1630, el sur de la Audiencia de Quito vivió una época de prosperidad originada en intensos intercambios comerciales entre la Nueva Granada y el Perú, y sobre todo en el amplio mercado de consumo creado por los centros mineros. Una moneda abundante, bajo la forma del oro extraído de las minas locales, alimentó nutridas transacciones y permitió inversiones en el comercio y en las haciendas agrícolas y ganaderas. Gracias al estudio de las escrituras de censos suscritos por el convento de monjas de Loja, la autora examina cómo funciona el crédito en la sociedad colonial y circula el capital. Este análisis demuestra la ambigüedad de aquel sistema de financiación tan común en la Colonia: mientras en el siglo XVI, va acentuando la prosperidad de la economía triunfante de por sí, en cambio en el XVII, constituye una

  18. A new procedure for imaging liver and spleen with water soluble contrast media in liposomes

    International Nuclear Information System (INIS)

    Zherbin, E.A.; Davidenkova, E.F.; Khanson, K.P.; Gubareva, A.V.; Zhdanova, N.V.; Aliyakparov, M.T.; Loshakova, L.V.; Fomina, Eh.V.; Rozenberg, O.A.

    1983-01-01

    The problems of long-term, reversible, and safe contrast investigation of liver and spleen and reduction of the irritating action of water-soluble contrast media on the wall of blood vessels are unresolved. The production and experimental application of contrast media encapsulated in liposomes are described. It is possible to produce a liposome preparation with 10-20 % Verografin content. After intravenous injection it leads to a quick (after 16-30 min), persisting (10-12 h) and reversible (24-30 h) contrast imaging of liver and spleen in rodents. The contrast medium has no pathological effects on heart, blood and circulatory system and on the morphology of liver, spleen, heart, lungs, kidneys and urinary bladder. The perspectives of clinical application of such contrast media are discussed. (author)

  19. The X-ray spectra of the black hole candidate 4U 1630-47 during its 2012 outburst

    Science.gov (United States)

    Wang, Y.; Mendez, M.

    2015-07-01

    Diaz Trigo et al. (2013) reported the detection of three Doppler-shifted emission lines arising from baryonic matter in the jet of 4U 1630-47 during its 2012 outburst. Here we propose an alternative model that, without the need of the lines from the jet, and with less free parameters, fits the same data equally well. In our model we allow the abundances of S and Fe in the interstellar medium to vary; the best-fitting values are, respectively, 1.5 and 0.5 times solar, consistent with recent findings. Our model also includes a moderately broad emission line and a narrow absorption line due to highly ionised Fe. (These lines are also present in the other observations of this source during the 2012 outburst.) This model fits well all the XMM-Newton observations of this source, both in burst and timing mode. In addition to the components that we fitted to the burst-mode data, the timing-mode observations show several absorption features due to ionised Fe and Ni, which reveal the presence of a highly-ionised absorber close to the source. Our model also fits well the burst-mode data using the most recent calibration files (March 2015), whereas the model from Diaz Trigo et al. does not.

  20. A LINK BETWEEN X-RAY EMISSION LINES AND RADIO JETS IN 4U 1630-47?

    Energy Technology Data Exchange (ETDEWEB)

    Neilsen, Joseph [Department of Astronomy, Boston University, Boston, MA 02215 (United States); Coriat, Mickaël [Department of Astronomy, University of Cape Town, Private Bag X3, Rondebosch 7701 (South Africa); Fender, Rob; Broderick, Jess W. [Department of Physics, Oxford University, Oxford OX1 3RH (United Kingdom); Lee, Julia C. [Harvard-Smithsonian Center for Astrophysics, Cambridge, MA 02138 (United States); Ponti, Gabriele [Max Planck Institute fur Extraterrestriche Physik, D-85748 Garching (Germany); Tzioumis, Anastasios K.; Edwards, Philip G., E-mail: neilsenj@bu.edu [CSIRO Astronomy and Space Science, Australia Telescope National Facility, P.O. Box 76, Epping, NSW 1710 (Australia)

    2014-03-20

    Recently, Díaz Trigo et al. reported an XMM-Newton detection of relativistically Doppler-shifted emission lines associated with steep-spectrum radio emission in the stellar-mass black hole candidate 4U 1630-47 during its 2012 outburst. They interpreted these lines as indicative of a baryonic jet launched by the accretion disk. Here we present a search for the same lines earlier in the same outburst using high-resolution X-ray spectra from the Chandra HETGS. While our observations (eight months prior to the XMM-Newton campaign) also coincide with detections of steep spectrum radio emission by the Australia Telescope Compact Array, we find no evidence for any relativistic X-ray emission lines. Indeed, despite ∼5 × brighter radio emission, our Chandra spectra allow us to place an upper limit on the flux in the blueshifted Fe XXVI line that is ≳ 20 × weaker than the line observed by Díaz Trigo et al. We explore several scenarios that could explain our differing results, including variations in the geometry of the jet or a mass-loading process or jet baryon content that evolves with the accretion state of the black hole. We also consider the possibility that the radio emission arises in an interaction between a jet and the nearby interstellar medium, in which case the X-ray emission lines might be unrelated to the radio emission.

  1. A LINK BETWEEN X-RAY EMISSION LINES AND RADIO JETS IN 4U 1630-47?

    International Nuclear Information System (INIS)

    Neilsen, Joseph; Coriat, Mickaël; Fender, Rob; Broderick, Jess W.; Lee, Julia C.; Ponti, Gabriele; Tzioumis, Anastasios K.; Edwards, Philip G.

    2014-01-01

    Recently, Díaz Trigo et al. reported an XMM-Newton detection of relativistically Doppler-shifted emission lines associated with steep-spectrum radio emission in the stellar-mass black hole candidate 4U 1630-47 during its 2012 outburst. They interpreted these lines as indicative of a baryonic jet launched by the accretion disk. Here we present a search for the same lines earlier in the same outburst using high-resolution X-ray spectra from the Chandra HETGS. While our observations (eight months prior to the XMM-Newton campaign) also coincide with detections of steep spectrum radio emission by the Australia Telescope Compact Array, we find no evidence for any relativistic X-ray emission lines. Indeed, despite ∼5 × brighter radio emission, our Chandra spectra allow us to place an upper limit on the flux in the blueshifted Fe XXVI line that is ≳ 20 × weaker than the line observed by Díaz Trigo et al. We explore several scenarios that could explain our differing results, including variations in the geometry of the jet or a mass-loading process or jet baryon content that evolves with the accretion state of the black hole. We also consider the possibility that the radio emission arises in an interaction between a jet and the nearby interstellar medium, in which case the X-ray emission lines might be unrelated to the radio emission

  2. Animated Dreamsi peaauhind läks Tšiili

    Index Scriptorium Estoniae

    2009-01-01

    Pimedate Ööde 13. filmifestivali teise alafestivali Animated Dreams auhinnasaajad : võitis Cristobal Leoni, Niles Atallah' ja Joaquin Cocina "Lucia", Anoba nominatsiooni sai Kaspar Jancise "Krokodill"

  3. FITOCENOSIS EN LOS MOGOTES DE LA GRAN MESETA DE GUANTÁNAMO, CUBA ORIENTAL

    Directory of Open Access Journals (Sweden)

    Reyes Orlando

    2013-07-01

    Full Text Available Los mogotes de la Gran Meseta de Guantánamo están constituidos por calizas durasde la Formación Charco Redondo. La temperatura del aire varía entre 22 y 240C yllueve de 1 200 a 1 400 mm al año. Mediante la metodología de la Escuela Zurich- Montpellier se describe un nuevo orden, Coccothrinaci leonis - Guapiretaliarufescentis, con su alianza Coccothrinaci leonis - Guapirion rufescentis y tresasociaciones. Bactrio cubensis - Podocarpodetum ekmanii y Phyllantho epiphyllanthi- Tabebuietum myrtifoliae que se establecen en la parte superior de los mogotes y laasociación Pileo fruticulosae - Thelypteridetum alatae en fragmentos verticales, lasdos primeras tienen una bien desarrollada estera radical donde se produce el reciclajede nutrientes de este ecosistema

  4. Localization and registration accuracy in image guided neurosurgery: a clinical study

    Energy Technology Data Exchange (ETDEWEB)

    Shamir, Reuben R.; Joskowicz, Leo [Hebrew University of Jerusalem, School of Engineering and Computer Science, Jerusalem (Israel); Spektor, Sergey; Shoshan, Yigal [Hadassah University Hospital, Department of Neurosurgery, School of Medicine, Jerusalem (Israel)

    2009-01-15

    To measure and compare the clinical localization and registration errors in image-guided neurosurgery, with the purpose of revising current assumptions. Twelve patients who underwent brain surgeries with a navigation system were randomly selected. A neurosurgeon localized and correlated the landmarks on preoperative MRI images and on the intraoperative physical anatomy with a tracked pointer. In the laboratory, we generated 612 scenarios in which one landmark pair was defined as the target and the remaining ones were used to compute the registration transformation. Four errors were measured: (1) fiducial localization error (FLE); (2) target registration error (TRE); (3) fiducial registration error (FRE); (4) Fitzpatrick's target registration error estimation (F-TRE). We compared the different errors and computed their correlation. The image and physical FLE ranges were 0.5-2.0 and 1.6-3.0 mm, respectively. The measured TRE, FRE and F-TRE were 4.1{+-}1.6, 3.9{+-}1.2, and 3.7{+-}2.2 mm, respectively. Low correlations of 0.19 and 0.37 were observed between the FRE and TRE and between the F-TRE and the TRE, respectively. The differences of the FRE and F-TRE from the TRE were 1.3{+-}1.0 mm (max=5.5 mm) and 1.3{+-}1.2 mm (max=7.3 mm), respectively. Contrary to common belief, the FLE presents significant variations. Moreover, both the FRE and the F-TRE are poor indicators of the TRE in image-to-patient registration. (orig.)

  5. SU-E-I-94: Automated Image Quality Assessment of Radiographic Systems Using An Anthropomorphic Phantom

    International Nuclear Information System (INIS)

    Wells, J; Wilson, J; Zhang, Y; Samei, E; Ravin, Carl E.

    2014-01-01

    Purpose: In a large, academic medical center, consistent radiographic imaging performance is difficult to routinely monitor and maintain, especially for a fleet consisting of multiple vendors, models, software versions, and numerous imaging protocols. Thus, an automated image quality control methodology has been implemented using routine image quality assessment with a physical, stylized anthropomorphic chest phantom. Methods: The “Duke” Phantom (Digital Phantom 07-646, Supertech, Elkhart, IN) was imaged twice on each of 13 radiographic units from a variety of vendors at 13 primary care clinics. The first acquisition used the clinical PA chest protocol to acquire the post-processed “FOR PRESENTATION” image. The second image was acquired without an antiscatter grid followed by collection of the “FOR PROCESSING” image. Manual CNR measurements were made from the largest and thickest contrast-detail inserts in the lung, heart, and abdominal regions of the phantom in each image. An automated image registration algorithm was used to estimate the CNR of the same insert using similar ROIs. Automated measurements were then compared to the manual measurements. Results: Automatic and manual CNR measurements obtained from “FOR PRESENTATION” images had average percent differences of 0.42%±5.18%, −3.44%±4.85%, and 1.04%±3.15% in the lung, heart, and abdominal regions, respectively; measurements obtained from “FOR PROCESSING” images had average percent differences of -0.63%±6.66%, −0.97%±3.92%, and −0.53%±4.18%, respectively. The maximum absolute difference in CNR was 15.78%, 10.89%, and 8.73% in the respective regions. In addition to CNR assessment of the largest and thickest contrast-detail inserts, the automated method also provided CNR estimates for all 75 contrast-detail inserts in each phantom image. Conclusion: Automated analysis of a radiographic phantom has been shown to be a fast, robust, and objective means for assessing radiographic

  6. Animated Dreamsi grand prix läks Tšiilisse / Kristiina Davidjants

    Index Scriptorium Estoniae

    Davidjants, Kristiina, 1974-

    2009-01-01

    Pimedate Ööde 13. filmifestivali teise alafestivali Animated Dreams auhinnasaajad: võitis Cristobal Leoni, Niles Atallah' ja Joaquin Cocina "Lucia", ANOBA nominatsiooni sai Kaspar Jancise "Krokodill". Lisatud nimekiri "Animated Dreamsi võitjad"

  7. Imaging findings of primary breast sarcoma: Results of a first multicenter study

    Energy Technology Data Exchange (ETDEWEB)

    Wienbeck, Susanne, E-mail: susanne.wienbeck@med.uni-goettingen.de [University of Göttingen, Institute of Diagnostic and Interventional Radiology, Robert- Koch-Str. 40, 37075 Göttingen (Germany); Meyer, Hans Jonas [University Hospital Halle, Department of Radiology, Ernst-Grube-Str. 40, 06120 Halle (Germany); Herzog, Aimee [University of Jena, Institute of Diagnostic and Interventional Radiology, Erlanger Allee 101, 07747 Jena (Germany); Nemat, Sogand [University of Saarland, Clinic for Diagnostic and Interventional Radiology, Kirrberger Str. 100, 66424 Homburg (Germany); Teifke, Andrea [University of Mainz, Department of Diagnostic and Interventional Radiology, Langenbeckstr. 1, 55131 Mainz (Germany); Heindel, Walter [University of Münster, Institute of Clinical Radiology, Albert-Schweitzer-Str. 33, 48149 Münster (Germany); Schäfer, Fritz [University of Kiel, Institute of Radiology and Neuroradiology, Arnold-Heller-Str. 3, 24105 Kiel (Germany); Kinner, Sonja [University of Essen, Institute of Diagnostic and Interventional Radiology and Neuroradiology, Hufelandstr. 55, 45147 Essen (Germany); Müller-Schimpfle, Markus [Clinic Frankfurt Höchst, Department of Radiology, Gotenstr. 6, 65929 Frankfurt am Main (Germany); Surov, Alexey [University Hospital Halle, Department of Radiology, Ernst-Grube-Str. 40, 06120 Halle (Germany); University of Leipzig, Department of Diagnostic and Interventional Radiology, Liebigstr. 20, 04103 Leipzig (Germany)

    2017-03-15

    Purpose: To investigate imaging findings in patients with primary breast sarcoma (PBS). Materials and methods: A retrospective search in the databases of 10 radiological departments in Germany from 2000 to 2011 was performed. Only histologically proven cases of PBS were included into the study. Mammography was available in 31 patients (33 lesions), ultrasound images in 24 patients (24 lesions), and for 10 patients (14 lesions) magnetic resonance imaging (MRI) of the breast was performed. The breast findings were classified according to the American College of Radiology Breast Imaging Reporting and Data Systems (BI-RADS) 5th edition categories. Collected data were evaluated by means of descriptive statistics. Results: Forty-two female patients (mean age 62.0 years, range, 30–86 years) were included in the study. Clinically, all women had painless lumps. Irregular (53.3% [16/30]) or oval (30.0% [9/30]) mass with indistinct (73.3% [22/30]) or microlobulated (10% [3/30]) margins were common findings on mammograms. Ultrasound revealed typically an irregular (79.2% [19/24]), hypoechoic (62.5% [15/24]) mass, with indistinct margins (79.2% [19/24]), and posterior acoustic shadowing (79.2% [19/24]). MRI showed irregular masses (81.8% [9/11]) with irregular or spiculated margins, and a rapid initial signal increase with a delayed washout in kinetic analysis. Conclusion: Overall, PBS has no pathognomonic imaging features and can mimic those of invasive mammary carcinoma. Breast sarcoma should be taken into the differential diagnosis of breast findings described above.

  8. Localization and registration accuracy in image guided neurosurgery: a clinical study

    International Nuclear Information System (INIS)

    Shamir, Reuben R.; Joskowicz, Leo; Spektor, Sergey; Shoshan, Yigal

    2009-01-01

    To measure and compare the clinical localization and registration errors in image-guided neurosurgery, with the purpose of revising current assumptions. Twelve patients who underwent brain surgeries with a navigation system were randomly selected. A neurosurgeon localized and correlated the landmarks on preoperative MRI images and on the intraoperative physical anatomy with a tracked pointer. In the laboratory, we generated 612 scenarios in which one landmark pair was defined as the target and the remaining ones were used to compute the registration transformation. Four errors were measured: (1) fiducial localization error (FLE); (2) target registration error (TRE); (3) fiducial registration error (FRE); (4) Fitzpatrick's target registration error estimation (F-TRE). We compared the different errors and computed their correlation. The image and physical FLE ranges were 0.5-2.0 and 1.6-3.0 mm, respectively. The measured TRE, FRE and F-TRE were 4.1±1.6, 3.9±1.2, and 3.7±2.2 mm, respectively. Low correlations of 0.19 and 0.37 were observed between the FRE and TRE and between the F-TRE and the TRE, respectively. The differences of the FRE and F-TRE from the TRE were 1.3±1.0 mm (max=5.5 mm) and 1.3±1.2 mm (max=7.3 mm), respectively. Contrary to common belief, the FLE presents significant variations. Moreover, both the FRE and the F-TRE are poor indicators of the TRE in image-to-patient registration. (orig.)

  9. X-Ray Observations of the Black Hole Transient 4U 1630-47 during 2 Years of X-Ray Activity

    Science.gov (United States)

    Tomsick, John A.; Corbel, Stéphane; Goldwurm, Andrea; Kaaret, Philip

    2005-09-01

    The black hole candidate (BHC) X-ray transient 4U 1630-47 continuously produced strong X-ray emission for more than 2 years during its 2002-2004 outburst, which is one of the brightest and longest outbursts ever seen from this source. We use more than 300 observations made with the Rossi X-Ray Timing Explorer (RXTE) to study the source throughout the outburst, along with hard X-ray images from the International Gamma-Ray Astrophysics Laboratory (INTEGRAL), which are critical for interpreting the RXTE data in this crowded field. The source exhibits extreme behaviors, which can be interpreted as an indication that the system luminosity approaches the Eddington limit. For 15 observations, fitting the spectral continuum with a disk-blackbody plus power-law model results in measured inner disk temperatures between 2.7 and 3.8 keV, and such temperatures are only rivaled by the brightest BHC systems, such as GRS 1915+105 and XTE J1550-564. If the high temperatures are caused by the dominance of electron scattering opacity in the inner regions of the accretion disk, it is theoretically required that the source luminosity be considerably higher than 20% of the Eddington limit. We detect a variety of high-amplitude variability, including hard 10-100 s flares, which peak at levels as much as 2-3 times higher than nonflare levels. This flaring occurs at the highest disk luminosities in a regime in which the source deviates from the Ldisk~T4in relationship that is seen at lower luminosities, possibly suggesting that we are seeing transitions between a Shakura & Sunyaev disk and a ``slim'' disk, which is predicted to occur at very high mass accretion rates. The X-ray properties in 2002-2004 are significantly different from those seen during the 1998 outburst, which is the only outburst with detected radio jet emission. Our results support the ``jet line'' concept recently advanced by Fender and coworkers. Our study allows for a test of the quantitative McClintock & Remillard

  10. Bagatellid : Maailm / Nele-Eva Steinfeld

    Index Scriptorium Estoniae

    Steinfeld, Nele-Eva

    2009-01-01

    Muusikasõnumeid maailmast: Cecilia Bartoli pälvis Leonie Sonningi auhinna. Lorin Maazel jätab hüvasti New Yorgi Filharmoonikutega. Leitud kaks uut Mozarti klaveriteost. Uudiseid konkursimaailmast. Rootsi Raadio P2 resideerivaks heliloojaks valiti Mirjam Tally

  11. Prima Vistale tuleb tuntud kirjanikke mitmest Euroopa riigist / Kaarel Kressa

    Index Scriptorium Estoniae

    Kressa, Kaarel, 1983-

    2010-01-01

    Prima Vista kirjandusfestivali külalisi: Leonie Swann, Attila Bartis, Dmitri Bõkov, Zinaida Lindén, Mihhail Šiškin, Fay Weldon, Jason Goodwin, Rosa Maria Rodríguez Magda, Inga Gaile, Juris Kronbergs, Guntars Godinš, Liana Langa

  12. Consequences of depletion of stratospheric ozone for terrestrial Antarctic ecosystems: the response of Deschampsia antarctica to enhanced UV-B radiation in a controlled environment

    NARCIS (Netherlands)

    Rozema, J.J.; Broekman, R.; Lud, D.; Huiskes, A.H.L.; Moerdijk-Poortvliet, T.C.W.; De Bakker, N.; Meijkamp, B.; Van Beem, A.

    2001-01-01

    Mini UV lamps were installed over antarctic plants at Leonie Island, Antarctic peninsula, and shoot length measurements of Deschampsia antarctica were performed during the austral summer January-February 1999. We studied the response of the antarctic hairgrass, Deschampsia antarctica to enhanced

  13. Patterns of diagnostic imaging and associated radiation exposure among long-term survivors of young adult cancer: a population-based cohort study

    International Nuclear Information System (INIS)

    Daly, Corinne; Urbach, David R.; Stukel, Thérèse A.; Nathan, Paul C.; Deitel, Wayne; Paszat, Lawrence F.; Wilton, Andrew S.; Baxter, Nancy N.

    2015-01-01

    Survivors of young adult malignancies are at risk of accumulated exposures to radiation from repetitive diagnostic imaging. We designed a population-based cohort study to describe patterns of diagnostic imaging and cumulative diagnostic radiation exposure among survivors of young adult cancer during a survivorship time period where surveillance imaging is not typically warranted. Young adults aged 20–44 diagnosed with invasive malignancy in Ontario from 1992–1999 who lived at least 5 years from diagnosis were identified using the Ontario Cancer Registry and matched 5 to 1 to randomly selected cancer-free persons. We determined receipt of 5 modalities of diagnostic imaging and associated radiation dose received by survivors and controls from years 5–15 after diagnosis or matched referent date through administrative data. Matched pairs were censored six months prior to evidence of recurrence. 20,911 survivors and 104,524 controls had a median of 13.5 years observation. Survivors received all modalities of diagnostic imaging at significantly higher rates than controls. Survivors received CT at a 3.49-fold higher rate (95 % Confidence Interval [CI]:3.37, 3.62) than controls in years 5 to 15 after diagnosis. Survivors received a mean radiation dose of 26 miliSieverts solely from diagnostic imaging in the same time period, a 4.57-fold higher dose than matched controls (95 % CI: 4.39, 4.81). Long-term survivors of young adult cancer have a markedly higher rate of diagnostic imaging over time than matched controls, imaging associated with substantial radiation exposure, during a time period when surveillance is not routinely recommended. The online version of this article (doi:10.1186/s12885-015-1578-1) contains supplementary material, which is available to authorized users

  14. Fiktiivne auhinnagala Lõuna-Prantsusmaal II / Madli Pesti

    Index Scriptorium Estoniae

    Pesti, Madli, 1980-

    2009-01-01

    Muljeid tänavusest 63. Avignoni teatrifestivalist. Pikemalt järgmistest etendustest: Krzysztof Warlikowski "(A)pollonia", Claude Regy "Ode Maritime" (Fernando Pessoa poeemi järgi), Frederico Leoni "Yo en el futuro" ("Mina tulevikus"), Thierry Bedard'i "Geko košmaarid" jt.

  15. The Disk Wind in the Rapidly Spinning Stellar-mass Black Hole 4U 1630-472 Observed with NuSTAR

    Science.gov (United States)

    King, Ashley L.; Walton, Dominic J.; Miller, Jon M.; Barret, Didier; Boggs, Steven E.; Christensen, Finn E.; Craig, William W.; Fabian, Andy C.; Furst, Felix; Hailey, Charles J.; hide

    2014-01-01

    We present an analysis of a short NuSTAR observation of the stellar-mass black hole and low-mass X-ray binary 4U 1630-472. Reflection from the inner accretion disk is clearly detected for the first time in this source, owing to the sensitivity of NuSTAR. With fits to the reflection spectrum, we find evidence for a rapidly spinning black hole, a* = 0.985(+0.005/-0.014) (1 sigma statistical errors). However, archival data show that the source has relatively low radio luminosity. Recently claimed relationships between jet power and black hole spin would predict either a lower spin or a higher peak radio luminosity. We also report the clear detection of an absorption feature at 7.03 +/- 0.03 keV, likely signaling a disk wind. If this line arises in dense, moderately ionized gas (log xi = 3.6(+0.2/-0.3) and is dominated by He-like Fe xxv, the wind has a velocity of v/c = 0.043(+0.002/-0.007) (12900(+600/-2100) km s(exp -1)). If the line is instead associated with a more highly ionized gas (log xi = 6.1(+0.7/-0.6)), and is dominated by Fe xxvi, evidence of a blueshift is only marginal, after taking systematic errors into account. Our analysis suggests the ionized wind may be launched within 200-1100 Rg, and may be magnetically driven.

  16. Radio-wavelength observations of magnetic fields on active dwarf-M, RS CVN and magnetic stars

    Energy Technology Data Exchange (ETDEWEB)

    Lang, K.R.

    1986-01-01

    The dwarf M stars YZ Canis Minoris and AD Leonis exhibit narrow band, slowly varying (hours) microwave emission that cannot be explained by conventional thermal radiation mechanisms. The dwarf M stars AD Leonis and Wolf 424 emit rapid spikes whose high brightness temperatures similarly require a nonthermal radiation process which could result from coherent mechanisms such as an electron-cyclotron maser or coherent-plasma radiation. If the electron-cyclotron maser emits at the second or third harmonic of the gyrofrequency, the coronal magnetic field strength H = 250 or 167 G and constraints on the plasma frequency imply an electron density of 6 x 10/sup 9//cm/sup 3/. Coherent-plasma radiation requires similar values of electron density but much weaker magnetic fields. Radio spikes from AD Leonis and Wolf 424 have rise times tau/sub R/ < 5 ms, indicating a linear size of L < 1.5 x 10/sup 8/ cm, or less than 0.005 of the stellar radius. Although Ap magnetic stars have strong dipole magnetic fields, they exhibit no detectable gyroresonant radiation, suggesting that these stars do not have hot, dense coronae. The binary RS CVn star UX Arietis exhibits variable emission at 6 cm wavelength on time scales ranging from 30 s to more than one hour. The shortest variation implies a linear size much less than that of the halo observed by VLBI techniques, and most probably sizes smaller than those of the component stars. The observed variations might be due to absorption by a thermal plasma located between the stars.

  17. 1578-IJBCS-Article-Karamoko Diarra

    African Journals Online (AJOL)

    hp

    (Bt), neem oil and methamidophos on larvae of P. xylostella under laboratory conditions. Leaf-dip ... providing income and nutrition and enabling small farms to .... hung vertically to air dry for 2 h. Control ..... brassicas in Asia and Africa. Crop.

  18. In utero diffusion tensor imaging of the fetal brain: A reproducibility study.

    Science.gov (United States)

    Jakab, András; Tuura, Ruth; Kellenberger, Christian; Scheer, Ianina

    2017-01-01

    Our purpose was to evaluate the within-subject reproducibility of in utero diffusion tensor imaging (DTI) metrics and the visibility of major white matter structures. Images for 30 fetuses (20-33. postmenstrual weeks, normal neurodevelopment: 6 cases, cerebral pathology: 24 cases) were acquired on 1.5 T or 3.0 T MRI. DTI with 15 diffusion-weighting directions was repeated three times for each case, TR/TE: 2200/63 ms, voxel size: 1 ∗ 1 mm, slice thickness: 3-5 mm, b-factor: 700 s/mm 2 . Reproducibility was evaluated from structure detectability, variability of DTI measures using the coefficient of variation (CV), image correlation and structural similarity across repeated scans for six selected structures. The effect of age, scanner type, presence of pathology was determined using Wilcoxon rank sum test. White matter structures were detectable in the following percentage of fetuses in at least two of the three repeated scans: corpus callosum genu 76%, splenium 64%, internal capsule, posterior limb 60%, brainstem fibers 40% and temporooccipital association pathways 60%. The mean CV of DTI metrics ranged between 3% and 14.6% and we measured higher reproducibility in fetuses with normal brain development. Head motion was negatively correlated with reproducibility, this effect was partially ameliorated by motion-correction algorithm using image registration. Structures on 3.0 T had higher variability both with- and without motion correction. Fetal DTI is reproducible for projection and commissural bundles during mid-gestation, however, in 16-30% of the cases, data were corrupted by artifacts, resulting in impaired detection of white matter structures. To achieve robust results for the quantitative analysis of diffusivity and anisotropy values, fetal-specific image processing is recommended and repeated DTI is needed to ensure the detectability of fiber pathways.

  19. The effects of altered levels of UV-B radiation on an Antarctic grass and lichen

    NARCIS (Netherlands)

    Lud, D.; Huiskes, A.H.L.; Moerdijk-Poortvliet, T.C.W.; Rozema, J.J.

    2001-01-01

    We report a long-term experiment on the photosynthetic response of natural vegetation of Deschampsia antarctica (Poaceae) and Turgidosculum complicatulum (Lichenes) to altered UV-B levels on Leonie Island, Antarctica. UV-B above the vegetation was reduced by filter screens during two seasons. Half

  20. Herschel/HIFI Observations of IRC+10216: Water Vapor in the Inner Envelope of a Carbon-rich Asymptotic Giant Branch Star

    NARCIS (Netherlands)

    Neufeld, D. A.; González-Alfonso, E.; Melnick, G.; Szczerba, R.; Schmidt, M.; Decin, L.; de Koter, A.; Schöier, F. L.; Cernicharo, J.

    2011-01-01

    We report the results of observations of 10 rotational transitions of water vapor toward the carbon-rich asymptotic giant branch (AGB) star IRC+10216 (CW Leonis), carried out with Herschel's HIFI instrument. Each transition was securely detected by means of observations using the dual beam switch

  1. Genome-scale data suggest reclassifications in the Leisingera-Phaeobacter cluster including proposals for Sedimentitalea gen. nov. and Pseudophaeobacter gen. nov.

    Directory of Open Access Journals (Sweden)

    Sven eBreider

    2014-08-01

    Full Text Available Earlier phylogenetic analyses of the marine Rhodobacteraceae (class Alphaproteobacteria genera Leisingera and Phaeobacter indicated that neither genus might be monophyletic. We here used phylogenetic reconstruction from genome-scale data, MALDI-TOF mass-spectrometry analysis and a re-assessment of the phenotypic data from the literature to settle this matter, aiming at a reclassification of the two genera. Neither Phaeobacter nor Leisingera formed a clade in any of the phylogenetic analyses conducted. Rather, smaller monophyletic assemblages emerged, which were phenotypically more homogeneous, too. We thus propose the reclassification of Leisingera nanhaiensis as the type species of a new genus as Sedimentitalea nanhaiensis gen. nov., comb. nov., the reclassification of Phaeobacter arcticus and Phaeobacter leonis as Pseudophaeobacter arcticus gen. nov., comb. nov. and Pseudophaeobacter leonis comb. nov., and the reclassification of Phaeobacter aquaemixtae, Phaeobacter caeruleus and Phaeobacter daeponensis as Leisingera aquaemixtae comb. nov., Leisingera caerulea comb. nov. and Leisingera daeponensis comb. nov. The genera Phaeobacter and Leisingera are accordingly emended.

  2. The Hungry Season

    African Journals Online (AJOL)

    start to go some way towards addressing this fundamental question. A delightful animation of The Hungry Season, commissioned by Leonie Joubert and funded by the University of Cape Town's Criminology. Department and the Embassy of Finland, is available online at http://www.youtube.com/ watch?v=iX77NZttLKo.

  3. THE DISK WIND IN THE RAPIDLY SPINNING STELLAR-MASS BLACK HOLE 4U 1630–472 OBSERVED WITH NuSTAR

    Energy Technology Data Exchange (ETDEWEB)

    King, Ashley L.; Miller, Jon M. [Department of Astronomy, University of Michigan, 500 Church Street, Ann Arbor, MI 48109-1042 (United States); Walton, Dominic J.; Fürst, Felix; Harrison, Fiona A. [Cahill Center for Astronomy and Astrophysics, California Institute of Technology, Pasadena, CA 91125 (United States); Barret, Didier [Université de Toulouse, UPS-OMP, IRAP, Toulouse (France); Boggs, Steven E.; Craig, William W.; Krivonos, Roman; Tomsick, John A. [Space Sciences Laboratory, 7 Gauss Way, University of California, Berkeley, CA 94720-7450 (United States); Christensen, Finn E. [DTU Space, National Space Institute, Technical University of Denmark, Elektrovej 327, DK-2800 Lyngby (Denmark); Fabian, Andy C. [Institute of Astronomy, University of Cambridge, Madingley Road, Cambridge CB3 0HA (United Kingdom); Hailey, Charles J.; Mori, Kaya [Columbia Astrophysics Laboratory, Columbia University, New York, NY 10027 (United States); Natalucci, Lorenzo [Istituto Nazionale di Astrofisica, INAF-IAPS, via del Fosso del Cavaliere, I-00133 Roma (Italy); Stern, Daniel [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Mail Stop 169-221, Pasadena, CA 91109 (United States); Zhang, William W., E-mail: ashking@umich.edu [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States)

    2014-03-20

    We present an analysis of a short NuSTAR observation of the stellar-mass black hole and low-mass X-ray binary 4U 1630–472. Reflection from the inner accretion disk is clearly detected for the first time in this source, owing to the sensitivity of NuSTAR. With fits to the reflection spectrum, we find evidence for a rapidly spinning black hole, a{sub ∗}=0.985{sub −0.014}{sup +0.005} (1σ statistical errors). However, archival data show that the source has relatively low radio luminosity. Recently claimed relationships between jet power and black hole spin would predict either a lower spin or a higher peak radio luminosity. We also report the clear detection of an absorption feature at 7.03 ± 0.03 keV, likely signaling a disk wind. If this line arises in dense, moderately ionized gas (log ξ=3.6{sub −0.3}{sup +0.2}) and is dominated by He-like Fe XXV, the wind has a velocity of v/c=0.043{sub −0.007}{sup +0.002} (12900{sub −2100}{sup +600} km s{sup –1}). If the line is instead associated with a more highly ionized gas (log ξ=6.1{sub −0.6}{sup +0.7}), and is dominated by Fe XXVI, evidence of a blueshift is only marginal, after taking systematic errors into account. Our analysis suggests the ionized wind may be launched within 200-1100 Rg, and may be magnetically driven.

  4. Dress as Civic Celebration in Late Sixteenth-Century Venice: The Woodcuts of Cesare Vecellio’s Habiti antichi et moderni and the Paintings of Paolo Veronese

    OpenAIRE

    Jones, Ann; Rosenthal, Margaret

    2014-01-01

    In this essay, we discuss words and images in sixteenth-century Venice in two forms: the prose commentary and woodcuts in Cesare Vecellio's Degli habiti antichi et moderni di diverse parti del mondo (Venice, 1590), and the paintings of Paulo Veronese from 1550 to 1578. Our theoretical framework is the analysis of ideology as it is materialized in the making, wearing and representation of clothing. We study three kinds of dress in Venice: the red silks worn by wealthy merchants, the black wool...

  5. Muusikamaailm. Magnus Lindbergi festivali jätk. Jonas Forsell taas ooperijuhiks. Marcello Panni uus ooper. György Kurtagile Sonningi preemia. Peter Gradenwitz lahkunud / Priit Kuusk

    Index Scriptorium Estoniae

    Kuusk, Priit, 1938-

    2002-01-01

    Soome helilooja Magnus Lindbergi mitmeid teoseid esitatakse Inglismaal. Rootsi heliloojast Jonas Forsellist sai jaanuaris Kopenhaageni trupi Den Anden Opera kunstiline juht. Firenzes tuli esiettekandele Marcello Panni uus ooper "The Banquet ئ Talking about Love". Helilooja György Kurtag pälvis Taani 2003.a. Leonie Sonningi muusikapreemia. 91aastasena suri muusikateadlane Peter Gradenwitz

  6. Leo

    Science.gov (United States)

    Murdin, P.

    2000-11-01

    (the Lion; abbrev. Leo, gen. Leonis; area 947 sq. deg.) A northern zodiacal constellation which lies between Cancer and Virgo, and culminates at midnight in early March. It represents the Nemean lion that, in Greek mythology, Hercules killed as the first of his 12 labors. Its brightest stars were cataloged by Ptolemy (c. AD 100-175) in the Almagest....

  7. Of mice and men: Traces of life in the death registries of the 1630 plague in Milano.

    Science.gov (United States)

    D'Amato, Alfonsina; Zilberstein, Gleb; Zilberstein, Svetlana; Compagnoni, Benedetto Luigi; Righetti, Pier Giorgio

    2018-05-30

    The death registries of the plague epidemic of 1630, stored at the Archivio di Stato of Milano, have been interrogated via the EVA film technology (ethyl vinyl acetate film studded with crushed strong anion and cation exchangers as well as C 8 resins). The EVA diskettes have been left in contact with the lower right margins of 11 different pages pertaining to the peak months of the raging disease (June through end of September) for 60-90min and then the captured material, after elution and digestion, analysed by mass spectrometry. The main findings: 17 Yersiniaceae family proteins, 31 different human keratins, 22 unique mouse keratins, about 400 peptides from different bacterial strains, 58 human tissue proteins and 130 additional mouse and rat tissue proteins. In addition, >60 plant proteins (notably potato, corn, rice, carrot and chickpeas), likely representing the meagre meals of the scribes, contaminating the pages, were detected. The significance of these unique findings is amply illustrated in the body of the article. Archivists, historians, librarians usually explore the texts of ancient and modern manuscript in order to extract the meaning of the writing and understand the mood, feelings, political, philosophical and/or religious ideas therein expressed by the authors. With the present EVA methodology (the only one, at present, able to access our Cultural Heritage without damaging or contaminating it) we interrogate, instead, the support, be it paper, parchment, wood panel, cloth, canvas and the like, in order to extract invisible data, such as the presence of drugs, medicaments, infectious pathogens, human and environmental contaminants. Metabolites, proteins and peptides thus captured are then analysed via mass spectrometry. The unique data mined by this technology should considerably enlarge the (so far) restricted horizon of the writing exploration and add new insight on the environmental conditions in which such documents were produced as well as

  8. Descartes on the Creation of the Eternal Truths

    Directory of Open Access Journals (Sweden)

    Danielle Macbeth

    2017-06-01

    Full Text Available On 15 April 1630, in a letter to Mersenne, Descartes announced that on his view God creates the truths of mathematics. Descartes returned to the theme in subsequent letters and some of his Replies but nowhere is the view systematically developed and defended. It is not clear why Descartes came to espouse the creation doctrine, nor even what exactly it is. Some have argued that his motivation was theological, that God creates the eternal truths, including the truths of logic, because and insofar as God is omnipotent andthe creator of all things. I develop and defend a different reading according to which Descartes was led to espouse the creation doctrine by a fundamental shift in his understanding of the correct mode of inquiry in metaphysics and mathematics: by 1630, the God-created truths came to play the role in inquiry that until then, in the Rules for the Direction of the Mind, had been played by images.

  9. The history of the Discalced Carmelite Monastery in Nowy Wiśnicz between 1630–2009

    Directory of Open Access Journals (Sweden)

    Zdzisław Gogola

    2013-12-01

    Full Text Available After winning the battle against the Turks at Chocim in 1621, Stanisław Lubomirski, the owner of Wiśnicz, founded the monastery of the Discalced Carmelites as a votive offering to God. Religious authorities feared the location of the monastery and church in private estates due to the potential impact of the court on religious life. In 1622 the founder began the construction at full swing, employing great numbers of labourers and prisoners of war. The process of the construction was supervised by Lubomirski’s court architect, an Italian Maciej Trapola. The buildings were characterized by a modern style of architecture and they occupied a unique position in the history of Polish architecture. The property was fortified and also served as defence for the castle of Wiśnicz. On May 26, 1630 a ceremony was held to introduce the Carmelites to the monastery in Wiśnicz. The construction works were completed in 1635. The interior was very well equipped and, in the seventeenth century, was considered one of the best equipped Discalced Carmelite monasteries. On September 1, 1650 the Swedes captured the castle and monastery destroying, looting and pillaging the most precious things including the library and the works of art. The monastery in Wiśnicz after the partition of Poland was incorporated into Austria. Emperor Joseph II through his policies led to the suppression of monasteries, including the monastery in Wiśnicz. He robbed the monastery, took away the monastic treasury and allocated the church estates to religious funds. The most valuable works of art were taken to Vienna (two wagons of paintings. The buildings of the monastery were converted to perform the functions of a prison, criminal court and housing for judges. After regaining independence in 1918, despite the protests of the Carmelites, the prison in the monastery continued to function. In September 1939, the Germans used it as a camp for prisoners of war and later a concentration

  10. SRTM Radar Image, Wrapped Color as Height/EarthKam Optical Honolulu, Hawaii

    Science.gov (United States)

    2000-01-01

    about EarthKAM is available at http://Earthkam.sdsc.edu/geo/ .The Shuttle Radar Topography Mission (SRTM) was carried onboard the Space Shuttle Endeavor, which launched on February 11,2000. It uses the same radar instrument that comprised the Spaceborne Imaging Radar-C/X-Band Synthetic Aperture Radar(SIR-C/X-SAR) that flew twice on the Endeavour in 1994. The mission is designed to collect three-dimensional measurements of the Earth's surface. To collect the 3-D data, engineers added a 60-meter-long (200-foot) mast, an additional C-band imaging antenna and improved tracking and navigation devices. The mission is a cooperative project between the National Aeronautics and Space Administration (NASA), the National Imagery and Mapping Agency (NIMA) and the German (DLR) and Italian (ASI)space agencies. It is managed by NASA's Jet Propulsion Laboratory, Pasadena, CA, for NASA's Earth Science Enterprise,Washington, DC.Size: 35 by 35 kilometers (22 by 22 miles) Location: 21.4 degrees North latitude, 157.8 degrees West longitude Orientation: North at top Original Data Resolution: SRTM, 30 meters (99 feet), EarthKAM Electronic Still Camera, 40 meters (132 feet) Date Acquired: SRTM, February 18, 2000; EarthKAM, February 12, 2000 Image: NASA/JPL/NIMA

  11. Development testing of the chemical analysis automation polychlorinated biphenyl standard analysis method during surface soils sampling at the David Witherspoon 1630 site

    International Nuclear Information System (INIS)

    Hunt, M.A.; Klatt, L.N.; Thompson, D.H.

    1998-02-01

    The Chemical Analysis Automation (CAA) project is developing standardized, software-driven, site-deployable robotic laboratory systems with the objective of lowering the per-sample analysis cost, decreasing sample turnaround time, and minimizing human exposure to hazardous and radioactive materials associated with DOE remediation projects. The first integrated system developed by the CAA project is designed to determine polychlorinated biphenyls (PCB) content in soil matrices. A demonstration and development testing of this system was conducted in conjuction with surface soil characterization activities at the David Witherspoon 1630 Site in Knoxville, Tennessee. The PCB system consists of five hardware standard laboratory modules (SLMs), one software SLM, the task sequence controller (TSC), and the human-computer interface (HCI). Four of the hardware SLMs included a four-channel Soxhlet extractor, a high-volume concentrator, a column cleanup, and a gas chromatograph. These SLMs performed the sample preparation and measurement steps within the total analysis protocol. The fifth hardware module was a robot that transports samples between the SLMs and the required consumable supplies to the SLMs. The software SLM is an automated data interpretation module that receives raw data from the gas chromatograph SLM and analyzes the data to yield the analyte information. The TSC is a software system that provides the scheduling, management of system resources, and the coordination of all SLM activities. The HCI is a graphical user interface that presents the automated laboratory to the analyst in terms of the analytical procedures and methods. Human control of the automated laboratory is accomplished via the HCI. Sample information required for processing by the automated laboratory is entered through the HCI. Information related to the sample and the system status is presented to the analyst via graphical icons

  12. Heat transfer in a fuel pin shipping container

    International Nuclear Information System (INIS)

    Ingham, J.G.

    1980-01-01

    Maximum cladding temperatures occur when the IDENT 1578 fuel pin shipping container is installed in the T-3 Cask. The maximum allowable cladding temperature of 800 0 F is reached when the rate of energy deposited in the 19-pin basket reaches 400 watts. Since 45% of the energy which is generated in the fuel escapes the 19-pin basket without being deposited, mostly gamma energy, the maximum allowable rate of heat generation is 400/.55 = 727 watts. Similarly, the maximum allowable cladding temperature of 800 0 F is reached when the rate of energy deposited in the 40-pin basket reaches 465 watts. Since 33% of the energy which is generated in the fuel escapes the 40-pin basket without being deposited, mostly gamma energy, the maximum allowable rate of heat generation is 465/.66 = 704 watts. The IDENT 1578 fuel pin shipping container therefore meets its thermal design criteria. IDENT 1578 can handle fuel pins with a decay heat load of 600 watts while maintaining the maximum fuel pin cladding temperature below 800 0 F. The emissivities which were determined from the test results for the basket tubes and container are relatively low and correspond to new, shiny conditions. As the IDENT 1578 container is exposed to high temperatures for extended periods of time during the transportation of fuel pins, the emissivities will probably increase. This will result in reduced temperatures

  13. The perihelion of Mercury advance and the light bending calculated in (enhanced) Newton's theory

    Czech Academy of Sciences Publication Activity Database

    Abramowicz, M. A.; Ellis, G. F. R.; Horák, Jiří; Wielgus, M.

    2014-01-01

    Roč. 46, č. 1 (2014), 1630/1-1630/14 ISSN 0001-7701 Grant - others:AV ČR(CZ) M100031242 Institutional support: RVO:67985815 Keywords : space curvature * Newton's gravity * Perihelion advance Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 1.771, year: 2014

  14. An overview of dinoflagellate cysts in recent sediments along the west coast of India

    Digital Repository Service at National Institute of Oceanography (India)

    DeSilva, M.S.; Anil, A.C.; DeCosta, P.M.

    using SURFER Fig. 1—Location map of sampling stations (26 coastal stations and 3 port areas) along the west coast of India. D’SILVA et al.: AN OVERVIEW OF DINOFLAGELLATE CYSTS IN RECENT SEDIMENTS 699 plots (SURFER 8 program). The relative... Xandarodinium variable Bujak Prot.div Protoperidinium latissimum (Kofoid) Balech – Prot.lat Protoperidinium leonis (Pavillard) Balech Quinquecuspis concreta (Reid) Harland Prot.leo Protoperidinium oblongum (Aurivillius) Balech Votadinium calvum Reid Prot...

  15. Patch photopatch test at Manipal

    Directory of Open Access Journals (Sweden)

    Panja Arindrajit

    1994-01-01

    Full Text Available Patch and photopatch testing was performed on 55 patients with history of photosensitivity using Scandanavian photo patch test antigens obtained from Chemotechnique Diagnostics AB Sweden. The commonest reactions were seen to perfume mix 4 (21.0%, PABA 3 (15.78%, promethazine hydrochloride 3 (15.78%, chlorpromazine hydrochloride 3 (15.78%, balsam of peru 2 (10.52%, usnic acid, hexachlorophane, musk ambrette and 6 methyl coumarin showed 1 positive reaction each (5.26% suggesting either phototoxicity or photo sensitization. Patch and photo patch test positive reaction suggesting allergic sensitisation was seen to balsam of peru 3 (23.0% perfume mix 3 (23.0% promethazine hydrochloride 2 (15.3% and PABA, 6 methyl coumarin, tribromosalicylanilide, atranorin and wood mix showed positive reaction in one case each (7.69%. We conclude that photoxic or photo allergic reaction is a problem in India and patch photo patch test should be performed in all cases of idiopathic light eruptions to rule out photo sensitisation and in cases where photo sensitivity of exogenous origin is suspected.

  16. No further incidence of sepsis after splenectomy for severe trauma: a multi-institutional experience of the trauma registry of the DGU with 1,630 patients

    Directory of Open Access Journals (Sweden)

    Heuer M

    2010-06-01

    Full Text Available Abstract Objective Non-operative management of blunt splenic injury in adults has been applied increasingly at the end of the last century. Therefore, the lifelong risk of overwhelming post-splenectomy infection has been the major impetus for preservation of the spleen. However, the prevalence of posttraumatic infection after splenectomy in contrast to a conservative management is still unknown. Objective was to determine if splenectomy is an independent risk factor for the development of posttraumatic sepsis and multi-organ failure. Methods 13,433 patients from 113 hospitals were prospective collected from 1993 to 2005. Patients with an injury severity score > 16, no isolated head injury, primary admission to a trauma center and splenic injury were included. Data were allocated according to the operative management into 2 groups (splenectomy (I and conservative managed patients (II. Results From 1,630 patients with splenic injury 758 patients undergoing splenectomy compared with 872 non-splenectomized patients. 96 (18.3% of the patients with splenectomy and 102 (18.5% without splenectomy had apparent infection after operation. Additionally, there was no difference in mortality (24.8% versus 22.2% in both groups. After massive transfusion of red blood cells (> 10 non-splenectomy patients showed a significant increase of multi-organ failure (46% vs. 40% and sepsis (38% vs. 25%. Conclusions Non-operative management leads to lower systemic infection rates and mortality in adult patients with moderate blunt splenic injury (grade 1-3 and should therefore be advocated. Patients with grade 4 and 5 injury, patients with massive transfusion of red blood cells and unstable patients should be managed operatively.

  17. Technical Report on the 6th Time Scale Algorithm Symposium and Tutorials

    Science.gov (United States)

    2016-03-29

    34Optimal Stopping" and Dr. Paul- Henning Kamp on the "Improved NTP Timekeeping" . The Symposium includes also 25 contributions on different topics...break SESSION VII - NTP Algorithms 15:50 16:30 Invited talk- Paul- Henning Kamp "Improved NTP Timekeeping" 16:30 16:50 An Auto-Regressive Moving-Average

  18. Also, spielen wir Theater / Aarne Vinkel

    Index Scriptorium Estoniae

    Vinkel, Aarne, 1918-2006

    1998-01-01

    Rets. rmt.: Kitching, Laurence. Europe's itinerant players and the advent of German-language theatre in Reval, Estonia. Unpublished petitions of the Swedish era, 1630-1692, in the Reval City Archives. Frankfurt am Main : P. Lang, 1996 (German sudies in Canada; 7); Das deutschsprachige Theater im baltischen Raum, 1630-1918. Frankfurt am Main : P. Lang, 1997 (Thalia Germanica; 1)

  19. Detroit – En by i forfald

    OpenAIRE

    Schultz, Agnethe; Mia, [No Value; Lise, [No Value; Nanna, [No Value; Borggaard, Mille; Kvorning, [No Value; Jacobsen, [No Value; Bjørnstrup, [No Value

    2014-01-01

    Through this bachelor project we have studied how to create incentive for economic growth in Detroit without losing the authenticity of the city, and how this can be co-creational in an attractive identity for Detroit. The outcome of our study is based on Sharon Zukin’s understanding of authenticity and identity in urban cities, Richard Florida’s theory of the Creative Class, and Leonie Sandercock’s assumptions of storytelling in city development. The conclusion of our study is formed as five...

  20. Synthesis and in vitro growth inhibitory activity of novel silyl- and trityl-modified nucleosides

    CSIR Research Space (South Africa)

    Panayides, Jenny-Lee

    2016-06-01

    Full Text Available -Farkas d, Hajierah Davids d,e , Leonie Harmse d , M. E. Christine Rey f , Ivan R. Green g, Stephen C. Pelly g, Robert Kiss c, Alexander Kornienko h, Willem A. L. van Otterlo a,g,⇑ a Molecular Sciences Institute, School of Chemistry, University..., Matieland 7602, South Africa hDepartment of Chemistry and Biochemistry, Texas State University, San Marcos, TX 78666, USA Abstract Seventeen silyl- and trityl-modified (5'-O- and 3',5'-di-O-) nucleosides were synthesized with the aim of investigating...

  1. Francisco Giralte y el sepulcro del obispo Gutierre de Carvajal

    Directory of Open Access Journals (Sweden)

    Vasallo Toranzo, Luis

    2013-12-01

    Full Text Available The high valuation placed on the tomb of Bishop Gutierre de Carvajal, sculpted by Francisco de Giralte, resulted in a lawsuit for which the most important artists from Toledo, Alcalá and Madrid were called to testify. Their testimonies, made during the crucial moment when Berruguete died and the court arrived at Madrid are very useful for understanding the artistic appreciation of a work. Thus, relevant artists of the period –Pompeyo Leoni, Nicolás Vergara el Viejo, Jácome Trezo or Juan Bautista de Toledo– attested to the perfect technique, the beauty of the carving, the multiplicity of personages represented next to the dead Bishop, and the wish to achieve their portrait likenesses.La alta tasación alcanzada por el sepulcro del obispo Gutierre de Carvajal, obra de Francisco Giralte, motivó un pleito al que fueron llamados los principales artistas de Toledo, Alcalá y Madrid. Sus testimonios, realizados en el crucial momento en que se produjo la muerte de Berruguete y llegó la corte a Madrid, son muy útiles para conocer la estimación artística de una obra, de la que personajes como Pompeyo Leoni, Nicolás de Vergara el Viejo, Jácome Trezo o Juan Bautista de Toledo ponderaron la perfección técnica, la belleza de su talla, la multiplicación de personajes representados junto al finado y la voluntad retratística presente en todos ellos.

  2. Lion walking freely in the Louvre

    OpenAIRE

    Dimitrijević, Braco

    2016-01-01

    Nel 1996 Braco Dimitrijević, intervistato da Jean-Hubert Martin per “Flash Art” ha affermato: Se si guarda la terra dalla luna non c’è praticamente alcuna distanza tra il Louvre e lo zoo. Ci sono gabbie allo zoo così come ci sono al Louvre. Il mio ultimo obiettivo è rimuovere le porte e vedere i leoni liberi al Louvre. Questo progetto utopico, donato a MoRE, si inserisce all’interno di quella linea di ricerca basata appunto sull’accostamento tra importanti collezioni espositive ed animali viv...

  3. 78 FR 37516 - Notice of a Request for Extension of a Currently Approved Information Collection

    Science.gov (United States)

    2013-06-21

    ... William Janis, International Economist, Import Policies and Export Reporting Division, AgStop 1021, U.S... Collection Coordinator, at (202) 690-1578. Comments may be sent to William Janis, International Economist...

  4. THEORETICAL CONCEPTIONS OF GEOGRAPHY TEACHERS

    Directory of Open Access Journals (Sweden)

    Eloy Montes Galbán

    2007-11-01

    Full Text Available The main goal of this research was to determine the current theoretical concepts handled by third stage basic education geography teachers. A non experimental descriptive study was made. Data was collected through a semi structured questionnaire. The population was conformed by the teachers who work at the National schools placed in the parishes Raul Leoni and Cacique Mara of Maracaibo city, Zulia State. There is not clarity in regard to the correct handling of the different geographic currents, and the slight notion teachers have leans towards a traditional, descriptive, retrospective memory based conception.

  5. Seasonal changes in lipid composition and glycogen storage associated with freeze-tolerance of the earthworm, Dendrobaena octaedra

    Czech Academy of Sciences Publication Activity Database

    Overgaard, J.; Tollarová, Michaela; Hedlund, K.; Petersen, S. O.; Holmstrup, M.

    2009-01-01

    Roč. 179, č. 5 (2009), s. 569-577 ISSN 0174-1578 Institutional research plan: CEZ:AV0Z50070508 Keywords : earthworms * freeze-tolerance * glycogen Subject RIV: ED - Physiology Impact factor: 1.897, year: 2009

  6. Peramalan trafik SMS Area Jabotabek Dengan Metode ARIMA

    Directory of Open Access Journals (Sweden)

    Lusi Alvina Tofani

    2012-09-01

    Full Text Available Dalam dunia telekomunikasi, pertukaran informasidituntut memiliki performansi yang baik. Salah satu layanantelekomunikasi yang banyak digunakan adalah SMS (ShortMessage Service. Dalam tugas akhir ini akan dilakukanpemodelan dan peramalan trafik SMS pada jaringan GSM(Global System for Mobile Communication area Jabotabekmenggunakan metode ARIMA. Penelitian ini dipusatkan denganmengambil data dari 2 lokasi SMSC (Short Message ServiceCenter yaitu SMSC yang menampung transaksi SMS peer topeer GSM-T dan SMSC yang menampung transaksi SMS alloperator. Data tersebut merupakan trafik harian selama 4 bulandari bulan Maret hingga Juni 2011 yang akan digunakan untukpemodelan dan Bulan Juli 2011 yang akan digunakan sebagaidata testing. Ada 2 kategori pemodelan yaitu untuk tipe SMSCall operator pada selang waktu 0-15 sec dan 16-30 sec sedangkantipe yang kedua yaitu tipe SMSC peer to peer GSM-T padaselang waktu 0-15 sec dan 16-30 sec. Dari penelitian ini diperoleh4 model dari data selama 4 bulan yaitu model ARIMA untuk alloperator 0-15 sec adalah ([6,9],1,2, model ARIMA untuk alloperator 16-30 sec adalah (1,0,[1,4,5], model ARIMA untuk peerto peer GSM-T 0-15 sec adalah (1,0,[1,7], dan model ARIMAuntuk peer to peer GSM-T 16-30 sec adalah ([1,5],0,5. Kemudianuntuk hasil peramalan dari 4 model tersebut didapatkan nilaiMAPE terendah yaitu pada model ARIMA untuk trafik alloperator GSM-T 0-15 sec sebesar 0,32883%. Hasil peramalan iniyang akan digunakan sebagai prediksi trafik kedepan.

  7. Changes in the pH and other soil chemical parameters in soil surrounding wood ant (.i.Formica polyctena./i.) nests

    Czech Academy of Sciences Publication Activity Database

    Jílková, Veronika; Matějíček, L.; Frouz, J.

    2011-01-01

    Roč. 47, č. 1 (2011), s. 72-76 ISSN 1164-5563 Institutional research plan: CEZ:AV0Z60660521 Keywords : wood ants * soil pH * nutrients Subject RIV: EH - Ecology, Behaviour Impact factor: 1.578, year: 2011

  8. Physical Nature and Orbital Behavior of the Eclipsing System UZ Leonis

    Science.gov (United States)

    Lee, Jae Woo; Park, Jang-Ho

    2018-03-01

    New CCD photometric observations of UZ Leo were obtained between 2012 February and 2013 April, and on 2017 February. Its physical properties were derived from detailed analyses of our light curves and existing radial velocities. The results indicate that this system is a totally eclipsing A-subtype overcontact binary with both a high fill-out factor of 76% and a third light source contributing 12% light in the B bandpass, 10% in V, and 7% in R. The light residuals between observations and theoretical models are satisfactorily fitted by adopting a magnetic cool spot on the more massive primary star. Including our 12 measurements, a total of 172 eclipse times were used for ephemeris computations. We found that the orbital period of UZ Leo has varied due to a periodic oscillation superposed on an upward parabolic variation. The observed period increase at a rate of +3.49× {10}-7 day yr‑1 can be plausibly explained by some combination of non-conservative mass transfer from the secondary to the primary component and angular momentum loss due to magnetic braking. The period and semi-amplitude of the oscillation are about 139 years and 0.0225 days, respectively, which is interpreted as a light-time effect due to a third component with a mass of {M}3\\sin {i}3=0.30 {M}ȯ . Because the third lights of 7%–12% indicate that the circumbinary object is very overluminous for its mass, it would possibly match a white dwarf, rather than an M-type main sequence.

  9. Assessment of volume and leak measurements during CPAP using a neonatal lung model.

    Science.gov (United States)

    Fischer, H S; Roehr, C C; Proquitté, H; Wauer, R R; Schmalisch, G

    2008-01-01

    Although several commercial devices are available which allow tidal volume and air leak monitoring during continuous positive airway pressure (CPAP) in neonates, little is known about their measurement accuracy and about the influence of air leaks on volume measurement. The aim of this in vitro study was the validation of volume and leak measurement under CPAP using a commercial ventilatory device, taking into consideration the clinical conditions in neonatology. The measurement accuracy of the Leoni ventilator (Heinen & Löwenstein, Germany) was investigated both in a leak-free system and with leaks simulated using calibration syringes (2-10 ml, 20-100 ml) and a mechanical lung model. Open tubes of variable lengths were connected for leak simulation. Leak flow was measured with the flow-through technique. In a leak-free system the mean relative volume error +/-SD was 3.5 +/- 2.6% (2-10 ml) and 5.9 +/- 0.7% (20-60 ml), respectively. The influence of CPAP level, driving flow, respiratory rate and humidification of the breathing gas on the volume error was negligible. However, an increasing F(i)O(2) caused the measured tidal volume to increase by up to 25% (F(i)O(2) = 1.0). The relative error +/- SD of the leak measurements was -0.2 +/- 11.9%. For leaks > 19%, measured tidal volume was underestimated by more than 10%. In conclusion, the present in vitro study showed that the Leoni allowed accurate volume monitoring under CPAP conditions similar to neonates. Air leaks of up to 90% of patient flow were reliably detected. For an F(i)O(2) > 0.4 and for leaks > 19%, a numerical correction of the displayed volume should be performed.

  10. 29 CFR 1630.2 - Definitions.

    Science.gov (United States)

    2010-07-01

    ..., organic brain syndrome, emotional or mental illness, and specific learning disabilities. (i) Major Life..., speaking, breathing, learning, and working. (j) Substantially limits—(1) The term substantially limits... poses a “direct threat” shall be based on an individualized assessment of the individual's present...

  11. TMFunction data: 1630 [TMFunction[Archive

    Lifescience Database Archive (English)

    Full Text Available Q347C ... yes drug transport; inter-domain communication TM6 Multidrug transporter, P...8183) Helix ... inter-domain communication; drug transport; substrate translocation; ATPase activity

  12. 5 CFR 1630.15 - Exemptions.

    Science.gov (United States)

    2010-01-01

    ... who furnished information to the Government under an express promise that the identity of the source... implied promise that the identity of the source would be held in confidence; (3) Maintained in connection..., Federal contracts, or access to classified information, but only to the extent that the disclosures of...

  13. The scientific renaissance 1450-1630

    CERN Document Server

    Hall, Marie Boas

    1994-01-01

    Stimulating, illuminating, and thoughtfully presented, this study explores the early stages of the scientific revolution. A noted historian of science examines the Copernican revolution, the anatomical work of Vesalius, the work of Paracelsus, Harvey's discovery of the circulatory system, the effects of Galileo's telescopic discoveries, and much more.

  14. 19 CFR 163.0 - Scope.

    Science.gov (United States)

    2010-04-01

    ... other inquiry conducted for the purposes of ascertaining the correctness of any entry, for determining... applicable to U.S. importers, exporters, and producers under the United States-Canada Free Trade Agreement and the North American Free Trade Agreement are contained in parts 10 and 181 of this chapter...

  15. 1630-IJBCS-Article-Soke Olajide

    African Journals Online (AJOL)

    hp

    and fern are peculiar to the ponds and their banks.The original vegetation of ... restoration by replanting with native trees. Restoration is a major ..... The aquatic habitat provided by ponds created by limestone excavation has also provided refuge for fish species and some plant species including ferns.There is need to assist ...

  16. Broadband spectral observation of a dMe star radio flare

    International Nuclear Information System (INIS)

    Guedel, M.; Benz, A.O.; Fuerst, E.; Simett, G.M.; Davis, R.J.

    1989-01-01

    A flare on the dMe star AD Leonis was simultaneously observed with the radio telescopes in Effelsberg, Jodrell Bank, and Arecibo using spectrometers at 1665, 166 and 1415 MHz with bandwidths of 25, 100 and 40 MHz respectively. The time coincidence confirms the stellar origin of the radiation. The flare emission was resolved into a multitude of broadband pulsations. The e-folding rise and decay times were of the order of the time resolution of the Effelsberg data (125 ms), or less. The circular polarization was ∼ 100%. Similar bursts, but 4 orders of magnitude less powerful, have been observed from the sun at lower frequencies

  17. Wing morph-specific differences in the metabolism and endocrine control of reserve mobilization in adult males of a flightless bug, Pyrrhocoris apterus (L.) (Heteroptera)

    Czech Academy of Sciences Publication Activity Database

    Socha, Radomír; Kodrík, Dalibor; Šula, Jan

    2005-01-01

    Roč. 175, - (2005), s. 557-565 ISSN 0174-1578 R&D Projects: GA AV ČR(CZ) IAA6007301 Institutional research plan: CEZ:AV0Z50070508 Keywords : male * protein * carbohydrate Subject RIV: ED - Physiology Impact factor: 1.539, year: 2005

  18. Orally administered marine (1-3)-Beta-D-glucan Phycarine stimulates both humoral and cellular immunity

    Czech Academy of Sciences Publication Activity Database

    Větvička, V.; Dvořák, B.; Větvičková, J.; Richter, Jan; Křižan, Jiří; Šíma, Petr; Yvin, J.; C.

    2007-01-01

    Roč. 40, - (2007), s. 291-298 ISSN 0141-8130 R&D Projects: GA ČR GA301/05/0078 Institutional research plan: CEZ:AV0Z50200510 Keywords : phagocytosis * immunity * cancer Subject RIV: EE - Microbiology, Virology Impact factor: 1.578, year: 2007

  19. Soil properties as indicators of treeline dynamics in relation to anthropogenic pressure and climate change

    Czech Academy of Sciences Publication Activity Database

    Moscatelli, M. C.; Bonifacio, E.; Chiti, T.; Cudlín, Pavel; Dinca, L.; Gömöryova, E.; Grego, S.; La Porta, N.; Karlinski, L.; Pellis, G.; Rudawska, M.; Squartini, A.; Zhiyanski, M.; Broll, G.

    2017-01-01

    Roč. 73, 1-2 (2017), s. 73-84 ISSN 0936-577X Institutional support: RVO:67179843 Keywords : ecosystem services * forest resilience * Mountains Subject RIV: EH - Ecology, Behaviour OBOR OECD: Environmental sciences (social aspects to be 5.7) Impact factor: 1.578, year: 2016

  20. Seasonal adaption of dwarf hamsters (Genus Phodopus): differences between species and their geographic origin

    Czech Academy of Sciences Publication Activity Database

    Müller, D.; Hauer, J.; Schöttner, Konrad; Fritzsche, P.; Weinert, D.

    2015-01-01

    Roč. 185, č. 8 (2015), s. 917-930 ISSN 0174-1578 Institutional support: RVO:60077344 Keywords : dwart hamsters * photoperiodism * critical photoperiod Subject RIV: ED - Physiology Impact factor: 1.884, year: 2015 http://link.springer.com/article/10.1007%2Fs00360-015-0926-4

  1. The face of the other: the particular versus the individual

    Directory of Open Access Journals (Sweden)

    Claire Farago

    Full Text Available Abstract Five interrelated case studies from the sixteenth to the twentieth centuries develop the dynamic contrast between portraiture and pictorial genres newly invented in and about Latin America that do not represent their subjects as individuals despite the descriptive focus on the particular. From Jean de Léry’s genre-defining proto-ethnographic text (1578 about the Tupinamba of Brazil to the treatment of the Creole upper class in New Spain as persons whose individuality deserves to be memorialized in contrast to the Mestizaje, African, and Indian underclass objectified as types deserving of scientific study, hierarchical distinctions between portraiture and ethnographic images can be framed in historical terms around the Aristotelian categories of the universal, the individual, and the particular. There are also some intriguing examples that destabilize these inherited distinctions, such as Puerto Rican artist José Campeche’s disturbing and poignant image of a deformed child, Juan Pantaléon Aviles, 1808; and an imaginary portrait of Moctezuma II, c. 1697, based on an ethnographic image, attributed to the leading Mexican painter Antonio Rodriguez. These anomalies serve to focus the study on the hegemonic position accorded to the viewing subject as actually precarious and unstable, always ripe for reinterpretation at the receiving end of European culture.

  2. Earliest evidence for human consumption of crayfish

    Czech Academy of Sciences Publication Activity Database

    Patoka, J.; Nývltová Fišáková, Miriam; Kalous, L.; Škrdla, Petr; Kuča, M.

    2014-01-01

    Roč. 87, č. 13 (2014), s. 1578-1585 ISSN 0011-216X Institutional research plan: CEZ:AV0Z80010507 Institutional support: RVO:68081758 Keywords : Crustaceans * anthropology of food * consumption * Small game * Neolithic Subject RIV: AC - Archeology, Anthropology, Ethnology Impact factor: 0.473, year: 2014

  3. Clustering of malaria treatment failure (TF) in Daraweesh: hints for host genetic susceptibility to TF with emphasis on immune-modulating SNPs

    DEFF Research Database (Denmark)

    Giha, Hayder A; ElGhazali, Gehad; Nasr, Amre

    2010-01-01

    In malaria, drug resistance and treatment failure (TF) are not synonymous, although are escalating together. Over 9 years of surveillances for malaria morbidity and TF in Daraweesh village in eastern Sudan (1991-2004), 136 donors (15-78 years) from 43 households, treated for 278 malaria episodes ...

  4. anirban dhar

    Indian Academy of Sciences (India)

    Home; Journals; Sadhana. ANIRBAN DHAR. Articles written in Sadhana. Volume 42 Issue 9 September 2017 pp 1571-1578. Analytical solution of groundwater waves in unconfined aquifers with sloping boundary · SELVA BALAJI MUNUSAMY ANIRBAN DHAR · More Details Abstract Fulltext PDF. A new analytical solution ...

  5. Income and its distribution in preindustrial Poland

    NARCIS (Netherlands)

    Malinowski, Mikołaj; van Zanden, Jan Luiten

    This article presents per capita GDP and income distribution estimates for preindustrial Poland. It is based on a social table for the Voivodeship of Cracow in 1578. Our evidence indicates that income in Poland was distributed more equally than in contemporary Holland. However, the extraction rate

  6. Genetic evidence reveals density-dependent mediated success of alternative mating behaviours in the European bitterling (Rhodeus sericeus)

    Czech Academy of Sciences Publication Activity Database

    Reichard, Martin; Smith, C.; Jordan, W. C.

    2004-01-01

    Roč. 13, č. 6 (2004), s. 1569-1578 ISSN 0962-1083 Grant - others:NATO/Royal Society(GB) fellowship; Royal Society(GB) Joint Project Institutional research plan: CEZ:AV0Z6093917 Keywords : fish * mating tactics * paternity Subject RIV: EG - Zoology Impact factor: 4.375, year: 2004

  7. Assessment of volume and leak measurements during CPAP using a neonatal lung model

    International Nuclear Information System (INIS)

    Fischer, H S; Roehr, C C; Proquitté, H; Wauer, R R; Schmalisch, G

    2008-01-01

    Although several commercial devices are available which allow tidal volume and air leak monitoring during continuous positive airway pressure (CPAP) in neonates, little is known about their measurement accuracy and about the influence of air leaks on volume measurement. The aim of this in vitro study was the validation of volume and leak measurement under CPAP using a commercial ventilatory device, taking into consideration the clinical conditions in neonatology. The measurement accuracy of the Leoni ventilator (Heinen and Löwenstein, Germany) was investigated both in a leak-free system and with leaks simulated using calibration syringes (2–10 ml, 20–100 ml) and a mechanical lung model. Open tubes of variable lengths were connected for leak simulation. Leak flow was measured with the flow-through technique. In a leak-free system the mean relative volume error ±SD was 3.5 ± 2.6% (2–10 ml) and 5.9 ± 0.7% (20–60 ml), respectively. The influence of CPAP level, driving flow, respiratory rate and humidification of the breathing gas on the volume error was negligible. However, an increasing F i O 2 caused the measured tidal volume to increase by up to 25% (F i O 2 = 1.0). The relative error ±SD of the leak measurements was −0.2 ± 11.9%. For leaks >19%, measured tidal volume was underestimated by more than 10%. In conclusion, the present in vitro study showed that the Leoni allowed accurate volume monitoring under CPAP conditions similar to neonates. Air leaks of up to 90% of patient flow were reliably detected. For an F i O 2 >0.4 and for leaks >19%, a numerical correction of the displayed volume should be performed

  8. Analysis of H2O in silicate glass using attenuated total reflectance (ATR) micro-FTIR spectroscopy

    Science.gov (United States)

    Lowenstern, Jacob B.; Pitcher, Bradley W.

    2013-01-01

    We present a calibration for attenuated total reflectance (ATR) micro-FTIR for analysis of H2O in hydrous glass. A Ge ATR accessory was used to measure evanescent wave absorption by H2O within hydrous rhyolite and other standards. Absorbance at 3450 cm−1 (representing total H2O or H2Ot) and 1630 cm−1 (molecular H2O or H2Om) showed high correlation with measured H2O in the glasses as determined by transmission FTIR spectroscopy and manometry. For rhyolite, wt%H2O=245(±9)×A3450-0.22(±0.03) and wt%H2Om=235(±11)×A1630-0.20(±0.03) where A3450 and A1630 represent the ATR absorption at the relevant infrared wavelengths. The calibration permits determination of volatiles in singly polished glass samples with spot size down to ~5 μm (for H2O-rich samples) and detection limits of ~0.1 wt% H2O. Basaltic, basaltic andesite and dacitic glasses of known H2O concentrations fall along a density-adjusted calibration, indicating that ATR is relatively insensitive to glass composition, at least for calc-alkaline glasses. The following equation allows quantification of H2O in silicate glasses that range in composition from basalt to rhyolite: wt%H2O=(ω×A3450/ρ)+b where ω = 550 ± 21, b = −0.19 ± 0.03, ρ = density, in g/cm3, and A3450 is the ATR absorbance at 3450 cm−1. The ATR micro-FTIR technique is less sensitive than transmission FTIR, but requires only a singly polished sample for quantitative results, thus minimizing time for sample preparation. Compared with specular reflectance, it is more sensitive and better suited for imaging of H2O variations in heterogeneous samples such as melt inclusions. One drawback is that the technique can damage fragile samples and we therefore recommend mounting of unknowns in epoxy prior to polishing. Our calibration should hold for any Ge ATR crystals with the same incident angle (31°). Use of a different crystal type or geometry would require measurement of several H2O-bearing standards to provide a crystal

  9. Functions locally dependent on finitely many coordinates

    Czech Academy of Sciences Publication Activity Database

    Hájek, Petr Pavel; Zizler, Václav

    2006-01-01

    Roč. 100, č. 2 (2006), s. 147-154 ISSN 1578-7303 R&D Projects: GA AV ČR(CZ) IAA100190502; GA ČR(CZ) GA201/04/0090 Institutional research plan: CEZ:AV0Z10190503 Keywords : smoothness * renormings * higher smoothness Subject RIV: BA - General Mathematics

  10. The Impact of Gender, Perceived Female Isolation and Beliefs in Traditional Roles for Women on Job Satisfaction.

    Science.gov (United States)

    Barclay, Lizabeth A.; And Others

    Past research has detailed conflicting results in investigations of sex differences and job satisfaction. To explain sex differences and job satisfaction within the framework of subtle treatment discrimination (a situation variable) and beliefs about roles for women (a person variable), 1578 employees of a large corporation completed demographic…

  11. Zahari Taha

    Indian Academy of Sciences (India)

    Home; Journals; Sadhana. Zahari Taha. Articles written in Sadhana. Volume 40 Issue 5 August 2015 pp 1567-1578. Analytical modelling of soccer heading · Zahari Taha Mohd Hasnun Arif Hassan Iskandar Hasanuddin · More Details Abstract Fulltext PDF. Heading occur frequently in soccer games and studies have shown ...

  12. Four point measurements of electrons using PEACE in the high-altitude cusp

    Czech Academy of Sciences Publication Activity Database

    Taylor, M. G. G. T.; Fazakerley, A. N.; Krauklis, I. C.; Owen, C.; Trávníček, Pavel; Dunlop, M. W.; Carter, P. J.; Coates, A. J.; Szita, S.; Watson, G.; Wilson, R. J.

    2001-01-01

    Roč. 19, - (2001), s. 1567-1578 ISSN 0992-7689 Grant - others:European Space Agency - Prodex(XE) IMF CS/SFe/571/2000 Institutional research plan: CEZ:AV0Z3042911 Keywords : magnetospheric physics * magnetopause * cusp and boundary layers Subject RIV: BE - Theoretical Physics Impact factor: 1.199, year: 2001

  13. Bridge over troubled water - valuing Russia's scientific landscape

    Czech Academy of Sciences Publication Activity Database

    Büntgen, Ulf

    2016-01-01

    Roč. 70, č. 1 (2016), s. 95-98 ISSN 0936-577X R&D Projects: GA MŠk(CZ) LO1415 Institutional support: RVO:67179843 Keywords : Environmental change * Brain drain * Interdisciplinary research * Paleo-archives * Russia * Scientific collaboration Subject RIV: EH - Ecology, Behaviour Impact factor: 1.578, year: 2016

  14. Christoph Scheiner and the optics of the eye. (German Title: Christoph Scheiner und die Optik des Auges)

    Science.gov (United States)

    Daxecker, Franz

    Some of Scheiner's discoveries and experiments are taken from the books «Oculus», (Innsbruck 1619) and «Rosa Ursina sive Sol» (Rome 1626-1630): determination of the radius of curvature of the cornea, discovery of the nasal exit of the visual nerve, increase in the curvature of the lens in case of accommodation, anatomy of the eye, light reaction of the pupil, contraction of the pupil during accommodation, Scheiner's test (double images caused by ametropia), stenopeic effect, crossing rays in the eye, aperture, description of the cataract treatment, refractive indices of various parts of the eye, eye model, visual pivot angle of the eye, proof of crossing rays on the retina, comparison of the camera obscura and the optics of the eye.

  15. Smoothness in Banach spaces. Selected problems

    Czech Academy of Sciences Publication Activity Database

    Fabian, Marián; Montesinos, V.; Zizler, Václav

    2006-01-01

    Roč. 100, č. 2 (2006), s. 101-125 ISSN 1578-7303 R&D Projects: GA ČR(CZ) GA201/04/0090; GA AV ČR(CZ) IAA100190610 Institutional research plan: CEZ:AV0Z10190503 Keywords : smooth norm * renorming * weakly compactly generated space Subject RIV: BA - General Mathematics

  16. Behavioral and Physiological Response of Baleen Whales to Ships and Ship Noise

    Science.gov (United States)

    2015-09-30

    1), 39-53, DOI 10.1578/AM.41.1.2015.39 Calambokidis, J and J. Barlow . 2013. Trends in humpback and blue whales off the US West Coast and their...in Technology and Experimental Methods. Marine Technology Society Journal 46(4): 46- 59. Southall, B, Calambokidis, J. Moretti, D, Barlow , J

  17. Evidence for proteins involved in prophenoloxidase cascade Eisenia fetida earthworms

    Czech Academy of Sciences Publication Activity Database

    Kohlerová, Petra; Šilerová, Marcela; Stijlemans, B.; Dieu, M.; Halada, Petr; Josková, Radka; Beschin, A.; De Baetselier, P.; Bilej, Martin

    2006-01-01

    Roč. 176, - (2006), s. 581-587 ISSN 0174-1578 R&D Projects: GA ČR GA310/04/0806; GA AV ČR KJB500200613 Institutional research plan: CEZ:AV0Z50200510 Keywords : protein * prophenoloxidase cascade * eisenia fetida Subject RIV: EE - Microbiology, Virology Impact factor: 1.740, year: 2006

  18. Generalized expectation with general kernels on g-semirings and its applications

    Czech Academy of Sciences Publication Activity Database

    Agahi, H.; Mesiar, Radko; Babakhani, A.

    2017-01-01

    Roč. 111, č. 3 (2017), s. 863-875 ISSN 1578-7303 Institutional support: RVO:67985556 Keywords : Fractional integral * g-expectation * Jensen’s inequality * Probability theory Subject RIV: BA - General Mathematics OBOR OECD: Pure mathematics Impact factor: 0.690, year: 2016 http://library.utia.cas.cz/separaty/2017/E/mesiar-0477104.pdf

  19. Au implantation into various types of silicate glasses

    Czech Academy of Sciences Publication Activity Database

    Malinský, Petr; Macková, Anna; Bočan, Jiří; Švecová, B.; Nekvindová, P.

    2009-01-01

    Roč. 267, - (2009), s. 1575-1578 ISSN 0168-583X R&D Projects: GA MŠk(CZ) LC06041 Institutional research plan: CEZ:AV0Z10480505 Keywords : Au+ ion implantation * Glass es * RBS Depth profiling Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.156, year: 2009

  20. The Relations of Stressful Events and Nonacademic Future Expectations in African American Adolescents: Gender Differences in Parental Monitoring

    Science.gov (United States)

    Cunningham, Michael; Mars, Dustin E.; Burns, Lateela J.

    2012-01-01

    Urban African American high school students (N = 206) completed a study to examine gender differences in parental monitoring and the effect on the relationship between exposure to stressful life events and nonacademic future expectations. Participant's ages range from 13 to 18 (M = 15.78, SD = 1.19). Participants reported high exposure to…

  1. Untitled

    African Journals Online (AJOL)

    forests. The leechs are classified in phylum Annelida, genera himinatis and the species that commonly affects man is nilotica (1, 2). They usually affect the oropharynx causing epistaxis, hemoptysis and hematemesis. ... Taboratory Methods and Diagnosis. 8th ed. Vol. II., pp- 1578 -. 1582. 7. Kunin C.M. 1907 A Ten Year ...

  2. 16 CFR 1630.4 - Test procedure.

    Science.gov (United States)

    2010-01-01

    ...) Test chamber. The test chamber shall consist of an open top hollow cube made of noncombustible material...) Gloves. Nonhygroscopic gloves (such as rubber polyethylene) for handling the sample after drying, and... in the draft-protected environment (hood with draft off) with its bottom in place. Wearing gloves...

  3. Translations on Latin America, Number 1630

    Science.gov (United States)

    1977-04-07

    Public Force ( EL COMERCIO , 25 Feb 77) 48 Ecuadorean-Bolivian Industrial Development Pact Signed ( EL TIEMPO, 28 Feb 77) 50 Oil Exports Analyzed... EL COMERCIO , 25 Feb 77) 52 Quayaquil Port Expansion Work Begun ( EL COMERCIO , 26 Feb 77) 53 Wheat Import Figures for March, April and May...GOVERNING PUBLIC FORCE Quito EL COMERCIO in Spanish 25 Peb 77 P 3 [Text] The public force, which shall comprise the Armed Forces and the National

  4. 29 CFR 1630.4 - Discrimination prohibited.

    Science.gov (United States)

    2010-07-01

    ...) Fringe benefits available by virtue of employment, whether or not administered by the covered entity; (g... and other related activities, and selection for leaves of absence to pursue training; (h) Activities sponsored by a covered entity including social and recreational programs; and (i) Any other term, condition...

  5. 78 FR 25956 - Gulf of Mexico Fishery Management Council; Public Meeting

    Science.gov (United States)

    2013-05-03

    ..., GIS Analyst; Gulf of Mexico Fishery Management Council; telephone: (813) 348-1630. SUPPLEMENTARY... as oil spills, invasive species, climate effects and coral diseases; spatial ecology methods and...

  6. Adolescent Moral Motivations for Civic Engagement: Clues to the Political Gender Gap?

    Science.gov (United States)

    Malin, Heather; Tirri, Kirsi; Liauw, Indrawati

    2015-01-01

    This study explored gender differences in moral motivations and civic engagement among adolescents to add to existing explanations for the gender gap in political engagement in the US. We examined moral motivations for civic engagement in a sample of 1578 high school seniors, using a mixed-methods analysis of survey and interview data. Multiple…

  7. Documentary and instrumental-based drought indices for the Czech Lands back to AD 1501

    Czech Academy of Sciences Publication Activity Database

    Brázdil, Rudolf; Dobrovolný, Petr; Trnka, Miroslav; Büntgen, Ulf; Řezníčková, Ladislava; Kotyza, O.; Valášek, H.; Štěpánek, Petr

    2016-01-01

    Roč. 70, 2-3 (2016), s. 103-117 ISSN 0936-577X R&D Projects: GA ČR GA13-04291S; GA MŠk(CZ) LO1415 Institutional support: RVO:67179843 Keywords : Documentary evidence * Climate reconstruction * Drought variability * Extreme years * Central Europe Subject RIV: EH - Ecology, Behaviour Impact factor: 1.578, year: 2016

  8. Drought trends over part of Central Europe between 1961 and 2014

    Czech Academy of Sciences Publication Activity Database

    Trnka, Miroslav; Balek, Jan; Štěpánek, Petr; Zahradníček, Pavel; Možný, M.; Eitzinger, Josef; Žalud, Zdeněk; Formayer, H.; Turňa, M.; Nejedlík, P.; Semerádová, Daniela; Hlavinka, Petr; Brázdil, Rudolf

    2016-01-01

    Roč. 70, oct (2016), s. 143-160 ISSN 0936-577X R&D Projects: GA MŠk(CZ) LO1415; GA ČR GA13-04291S Institutional support: RVO:67179843 Keywords : SPI * PDSI * SPEI * Z-index * ICDI * Drought climatology * Climate trends Subject RIV: EH - Ecology, Behaviour Impact factor: 1.578, year: 2016

  9. Spinal imaging and image analysis

    CERN Document Server

    Yao, Jianhua

    2015-01-01

    This book is instrumental to building a bridge between scientists and clinicians in the field of spine imaging by introducing state-of-the-art computational methods in the context of clinical applications.  Spine imaging via computed tomography, magnetic resonance imaging, and other radiologic imaging modalities, is essential for noninvasively visualizing and assessing spinal pathology. Computational methods support and enhance the physician’s ability to utilize these imaging techniques for diagnosis, non-invasive treatment, and intervention in clinical practice. Chapters cover a broad range of topics encompassing radiological imaging modalities, clinical imaging applications for common spine diseases, image processing, computer-aided diagnosis, quantitative analysis, data reconstruction and visualization, statistical modeling, image-guided spine intervention, and robotic surgery. This volume serves a broad audience as  contributions were written by both clinicians and researchers, which reflects the inte...

  10. Muusikamaailm : IMC preemia Oscar Petersonile. Kammermuusika Kuhmos. Bachi festival Leipzigis / Priit Kuusk

    Index Scriptorium Estoniae

    Kuusk, Priit, 1938-

    2000-01-01

    O. Peterson pälvis tänavuse Rahvusvahelise Muusikanõukogu preemia (International Music Council/UNESCO Music Prize). 16.-30. juulini toimuvast Kuhmo kammermuusikafestivalist Soomes. Leipzigis toimuvast Bachi-festivalist

  11. 77 FR 20382 - Whitestone Power and Communications; Notice of Preliminary Permit Application Accepted for Filing...

    Science.gov (United States)

    2012-04-04

    ... (FPA), proposing to study the feasibility of the Microturbine Hydrokinetic River-In-Stream Energy.... Applicant Contact: Mr. Steven M. Selvaggio, Whitestone Power and Communications, P.O. Box 1630, Delta...

  12. 20 CFR 404.1603 - Basic responsibilities for us and the State.

    Science.gov (United States)

    2010-04-01

    ... are made accurately and promptly; (2) Provide an organizational structure, adequate facilities... projects (§ 404.1629); (9) Coordinate with other agencies (§ 404.1630); (10) Safeguard the records created...

  13. Image compression of bone images

    International Nuclear Information System (INIS)

    Hayrapetian, A.; Kangarloo, H.; Chan, K.K.; Ho, B.; Huang, H.K.

    1989-01-01

    This paper reports a receiver operating characteristic (ROC) experiment conducted to compare the diagnostic performance of a compressed bone image with the original. The compression was done on custom hardware that implements an algorithm based on full-frame cosine transform. The compression ratio in this study is approximately 10:1, which was decided after a pilot experiment. The image set consisted of 45 hand images, including normal images and images containing osteomalacia and osteitis fibrosa. Each image was digitized with a laser film scanner to 2,048 x 2,048 x 8 bits. Six observers, all board-certified radiologists, participated in the experiment. For each ROC session, an independent ROC curve was constructed and the area under that curve calculated. The image set was randomized for each session, as was the order for viewing the original and reconstructed images. Analysis of variance was used to analyze the data and derive statistically significant results. The preliminary results indicate that the diagnostic quality of the reconstructed image is comparable to that of the original image

  14. 75 FR 11997 - Proposed Collection; Comment Request for Regulation Project

    Science.gov (United States)

    2010-03-12

    ... Paperwork Reduction Act of 1995, Public Law 104-13 (44 U.S.C. 3506(c)(2)(A)). Currently, the IRS is... Trust as Part of an Estate (Sec. 1.645-1). DATES: Written comments should be received on or before May... INFORMATION: Title: Election to Treat Trust as Part of an Estate. OMB Number: 1545-1578. Regulation Project...

  15. A long-term chronology of summer half-year hailstorms for South Moravia, Czech Republic

    Czech Academy of Sciences Publication Activity Database

    Brázdil, Rudolf; Chromá, Kateřina; Valášek, H.; Dolák, Lukáš; Řezníčková, Ladislava; Zahradníček, Pavel; Dobrovolný, Petr

    2016-01-01

    Roč. 71, č. 2 (2016), s. 91-109 ISSN 0936-577X R&D Projects: GA ČR GA13-19831S; GA MŠk(CZ) LO1415 Institutional support: RVO:67179843 Keywords : Hailstorms * Hailstorm days * Damaging hailstorms * Documentary data * Meteoro-logical observations * Fluctuation * South Moravia Subject RIV: DG - Athmosphere Sciences, Meteorology Impact factor: 1.578, year: 2016

  16. Renormings of C(K) spaces

    Czech Academy of Sciences Publication Activity Database

    Smith, Richard James; Troyanski, S.

    2010-01-01

    Roč. 104, č. 2 (2010), s. 375-412 ISSN 1578-7303 R&D Projects: GA ČR GA201/07/0394 Institutional research plan: CEZ:AV0Z10190503 Keywords : uniformly rotund norms * Frechet * Gateaux Subject RIV: BA - General Mathematics Impact factor: 0.400, year: 2010 http://www.springerlink.com/content/430027876375w58x/

  17. Gender Differences in Adolescents' Choice of Heroes and Admired Adults in Five Countries

    Science.gov (United States)

    Estrada, Juan Diego; García-Ael, Cristina; Martorell, José Luis

    2015-01-01

    Seven hundred and sixty-eight adolescents from five countries and regions (USA, Spain, Hong Kong, Qatar, and Malaysia), aged 13-19 (M?=?15.78; SD?=?1.28) years, responded to a questionnaire designed to determine who was their most admired famous adult or hero. Male heroes clearly outnumbered admired females (73.3% vs. 26.7%). There was a pattern…

  18. Vaimuliku ja ajalookirjutaja Timann Brakeli "Kristlik vestlus" (1579) kui alahinnatud ajalooallikas / Aija Sakova-Merivee

    Index Scriptorium Estoniae

    Sakova-Merivee, Aija, 1980-

    2014-01-01

    Arvustus: Timann Brakel, Peter von Brakel. Christlich Gesprech. Darstellung der Geshcichte Livlands vor und während des "Livländischen Krieges" bis 1578 in gereimter Dialogform und Prosa von dem Prediger und Geschichtsschreiber Timann Brakel. Originaltext und Kommentaren, Erzählungen, Bildern und dem Lebenslauf des Timann Brakel. (Beiträge zur baltischen Geschichte, Band 19). Hirschheydt, 2012

  19. Membrane properties of Enchytraeus albidus originating from contrasting environments: a comparative analysis

    Czech Academy of Sciences Publication Activity Database

    Fisker, K. V.; Bouvrais, H.; Overgaard, J.; Schöttner, Konrad; Ipsen, J. H.; Holmstrup, M.

    2015-01-01

    Roč. 185, č. 4 (2015), s. 389-400 ISSN 0174-1578 R&D Projects: GA MŠk(CZ) EE2.3.30.0032 Institutional support: RVO:60077344 Keywords : membrane fluidity * fluorescence anisotropy * bending rigidity Subject RIV: ED - Physiology Impact factor: 1.884, year: 2015 http://link.springer.com/article/10.1007%2Fs00360-015-0895-7

  20. Expression of b-catenins and cadherins by follicular dendritic dells in human lymph nodes

    Czech Academy of Sciences Publication Activity Database

    Müller, Julius; Tvrdík, Daniel; Dvořák, Richard; Djaborkhel, Rashed; Mandys, Václav; Bednář, B.; Raška, Ivan; Lojda, Z.

    2000-01-01

    Roč. 102, - (2000), s. 369-380 ISSN 0065-1281 R&D Projects: GA ČR GA302/99/0587; GA ČR GA304/00/1481; GA MŠk VS96129; GA ČR GA304/94/1578 Institutional research plan: CEZ:AV0Z5039906 Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 0.943, year: 2000

  1. La teoría de la causalidad natural de Francisco Sánchez el escéptico

    Directory of Open Access Journals (Sweden)

    Rafael V. Orden Jiménez

    2003-01-01

    Full Text Available The most popular work of Francisco Sánchez, Quo nihil scitur (1581, transmits an absolutely sceptic thought. However, other writings like Carmen de Cometa anni M.D.LXXVII (1578, offer us different ideas about how Sánchez considers possible the scientific knowledge like, for example, his idea about the casual relations between natural objects.

  2. Forest ecosystem services affected by natural disturbances, climate and land-use changes in the Tatra Mountains

    Czech Academy of Sciences Publication Activity Database

    Fleischer, P.; Pichler, V.; Holko, L.; Fleischer Jr., P.; Máliš, F.; Gömöryová, E.; Cudlín, Pavel; Holeksa, J.; Michalová, Z.; Homolová, Z.; Škvarenina, J.; Střelcová, K.; Hlaváč, P.

    2017-01-01

    Roč. 73, 1-2 (2017), s. 57-71 ISSN 0936-577X R&D Projects: GA MŠk(CZ) LO1415 Institutional support: RVO:67179843 Keywords : Forest ecosystem state * Bark beetle outbreak * Long-term research Subject RIV: EH - Ecology, Behaviour OBOR OECD: Environmental sciences (social aspects to be 5.7) Impact factor: 1.578, year: 2016

  3. Speckle imaging algorithms for planetary imaging

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, E. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    I will discuss the speckle imaging algorithms used to process images of the impact sites of the collision of comet Shoemaker-Levy 9 with Jupiter. The algorithms use a phase retrieval process based on the average bispectrum of the speckle image data. High resolution images are produced by estimating the Fourier magnitude and Fourier phase of the image separately, then combining them and inverse transforming to achieve the final result. I will show raw speckle image data and high-resolution image reconstructions from our recent experiment at Lick Observatory.

  4. Retinal Imaging and Image Analysis

    Science.gov (United States)

    Abràmoff, Michael D.; Garvin, Mona K.; Sonka, Milan

    2011-01-01

    Many important eye diseases as well as systemic diseases manifest themselves in the retina. While a number of other anatomical structures contribute to the process of vision, this review focuses on retinal imaging and image analysis. Following a brief overview of the most prevalent causes of blindness in the industrialized world that includes age-related macular degeneration, diabetic retinopathy, and glaucoma, the review is devoted to retinal imaging and image analysis methods and their clinical implications. Methods for 2-D fundus imaging and techniques for 3-D optical coherence tomography (OCT) imaging are reviewed. Special attention is given to quantitative techniques for analysis of fundus photographs with a focus on clinically relevant assessment of retinal vasculature, identification of retinal lesions, assessment of optic nerve head (ONH) shape, building retinal atlases, and to automated methods for population screening for retinal diseases. A separate section is devoted to 3-D analysis of OCT images, describing methods for segmentation and analysis of retinal layers, retinal vasculature, and 2-D/3-D detection of symptomatic exudate-associated derangements, as well as to OCT-based analysis of ONH morphology and shape. Throughout the paper, aspects of image acquisition, image analysis, and clinical relevance are treated together considering their mutually interlinked relationships. PMID:22275207

  5. ImageX: new and improved image explorer for astronomical images and beyond

    Science.gov (United States)

    Hayashi, Soichi; Gopu, Arvind; Kotulla, Ralf; Young, Michael D.

    2016-08-01

    The One Degree Imager - Portal, Pipeline, and Archive (ODI-PPA) has included the Image Explorer interactive image visualization tool since it went operational. Portal users were able to quickly open up several ODI images within any HTML5 capable web browser, adjust the scaling, apply color maps, and perform other basic image visualization steps typically done on a desktop client like DS9. However, the original design of the Image Explorer required lossless PNG tiles to be generated and stored for all raw and reduced ODI images thereby taking up tens of TB of spinning disk space even though a small fraction of those images were being accessed by portal users at any given time. It also caused significant overhead on the portal web application and the Apache webserver used by ODI-PPA. We found it hard to merge in improvements made to a similar deployment in another project's portal. To address these concerns, we re-architected Image Explorer from scratch and came up with ImageX, a set of microservices that are part of the IU Trident project software suite, with rapid interactive visualization capabilities useful for ODI data and beyond. We generate a full resolution JPEG image for each raw and reduced ODI FITS image before producing a JPG tileset, one that can be rendered using the ImageX frontend code at various locations as appropriate within a web portal (for example: on tabular image listings, views allowing quick perusal of a set of thumbnails or other image sifting activities). The new design has decreased spinning disk requirements, uses AngularJS for the client side Model/View code (instead of depending on backend PHP Model/View/Controller code previously used), OpenSeaDragon to render the tile images, and uses nginx and a lightweight NodeJS application to serve tile images thereby significantly decreasing the Time To First Byte latency by a few orders of magnitude. We plan to extend ImageX for non-FITS images including electron microscopy and radiology scan

  6. Aquatic insects of lowland rainforest in Papua New Guinea: assemblage structure in relation to habitat type

    Czech Academy of Sciences Publication Activity Database

    Klečka, Jan

    2015-01-01

    Roč. 70, č. 12 (2015), s. 1621-1630 ISSN 0006-3088 Institutional support: RVO:60077344 Keywords : community structure * biodiversity * aquatic insects Subject RIV: EH - Ecology, Behaviour Impact factor: 0.719, year: 2015

  7. Imaging system design and image interpolation based on CMOS image sensor

    Science.gov (United States)

    Li, Yu-feng; Liang, Fei; Guo, Rui

    2009-11-01

    An image acquisition system is introduced, which consists of a color CMOS image sensor (OV9620), SRAM (CY62148), CPLD (EPM7128AE) and DSP (TMS320VC5509A). The CPLD implements the logic and timing control to the system. SRAM stores the image data, and DSP controls the image acquisition system through the SCCB (Omni Vision Serial Camera Control Bus). The timing sequence of the CMOS image sensor OV9620 is analyzed. The imaging part and the high speed image data memory unit are designed. The hardware and software design of the image acquisition and processing system is given. CMOS digital cameras use color filter arrays to sample different spectral components, such as red, green, and blue. At the location of each pixel only one color sample is taken, and the other colors must be interpolated from neighboring samples. We use the edge-oriented adaptive interpolation algorithm for the edge pixels and bilinear interpolation algorithm for the non-edge pixels to improve the visual quality of the interpolated images. This method can get high processing speed, decrease the computational complexity, and effectively preserve the image edges.

  8. A note on J-sets of linear operators

    Czech Academy of Sciences Publication Activity Database

    Azimi, M.R.; Müller, Vladimír

    2011-01-01

    Roč. 105, č. 2 (2011), s. 449-453 ISSN 1578-7303 R&D Projects: GA ČR GA201/09/0473; GA AV ČR IAA100190903 Institutional research plan: CEZ:AV0Z10190503 Keywords : hypercyclic vectors * orbits * J-sets Subject RIV: BA - General Mathematics Impact factor: 0.340, year: 2011 http://www.springerlink.com/content/67872w605844038v/

  9. Some remarks on farthest points

    Czech Academy of Sciences Publication Activity Database

    Montesinos, V.; Zizler, P.; Zizler, Václav

    2011-01-01

    Roč. 105, č. 1 (2011), s. 119-131 ISSN 1578-7303 R&D Projects: GA AV ČR IAA100190901 Institutional research plan: CEZ:AV0Z10190503 Keywords : farthest points * strongly exposed points * generic differentiability * convex functions Subject RIV: BA - General Mathematics Impact factor: 0.340, year: 2011 http://link.springer.com/article/10.1007%2Fs13398-011-0012-z

  10. Topological properties of function spaces over ordinal spaces

    Czech Academy of Sciences Publication Activity Database

    Gabriyelyan, S.; Grebík, Jan; Kąkol, Jerzy; Zdomskyy, L.

    2017-01-01

    Roč. 111, č. 4 (2017), s. 1157-1161 ISSN 1578-7303 R&D Projects: GA ČR GF16-34860L Institutional support: RVO:67985840 Keywords : Ascoli * rK-space * ordinal space Subject RIV: BA - General Mathematics OBOR OECD: Pure mathematics Impact factor: 0.690, year: 2016 https://link.springer.com/article/10.1007%2Fs13398-016-0354-7

  11. Finitely fibered Rosenthal compacta and trees

    Czech Academy of Sciences Publication Activity Database

    Kubiś, Wieslaw; Moltó, A.

    2011-01-01

    Roč. 105, č. 1 (2011), s. 23-37 ISSN 1578-7303 R&D Projects: GA AV ČR IAA100190901 Institutional research plan: CEZ:AV0Z10190503 Keywords : tree * Rosenthal compact * 2-fibered * 3-determined space Subject RIV: BA - General Mathematics Impact factor: 0.340, year: 2011 http://www.springerlink.com/content/d06q5087nx546785/

  12. The Lelek fan and the Poulsen simplex as Fraissé limits

    Czech Academy of Sciences Publication Activity Database

    Kubiś, Wieslaw; Kwiatkowska, A.

    2017-01-01

    Roč. 111, č. 4 (2017), s. 967-981 ISSN 1578-7303 R&D Projects: GA ČR(CZ) GAP201/12/0290 Institutional support: RVO:67985840 Keywords : Lelek fan * smooth fan * Fraissé limit Subject RIV: BA - General Mathematics OBOR OECD: Pure mathematics Impact factor: 0.690, year: 2016 https://link.springer.com/article/10.1007%2Fs13398-016-0339-6

  13. Parovičenko spaces with structures

    Czech Academy of Sciences Publication Activity Database

    Kubiś, Wieslaw; Kucharski, A.; Turek, S.

    2014-01-01

    Roč. 108, č. 2 (2014), s. 989-1004 ISSN 1578-7303 R&D Projects: GA ČR(CZ) GAP201/12/0290 Institutional support: RVO:67985840 Keywords : structured compact space * normally supercompact space * median space Subject RIV: BA - General Mathematics Impact factor: 0.776, year: 2014 http://link.springer.com/article/10.1007%2Fs13398-013-0156-0

  14. Free locally convex spaces with a small base

    Czech Academy of Sciences Publication Activity Database

    Gabriyelyan, S.; Kąkol, Jerzy

    2017-01-01

    Roč. 111, č. 2 (2017), s. 575-585 ISSN 1578-7303 R&D Projects: GA ČR GF16-34860L Institutional support: RVO:67985840 Keywords : compact resolution * free locally convex space * G-base Subject RIV: BA - General Mathematics OBOR OECD: Pure mathematics Impact factor: 0.690, year: 2016 http://link.springer.com/article/10.1007%2Fs13398-016-0315-1

  15. A Red Oak Data Bank for Computer Simulations of Secondary Processing

    Science.gov (United States)

    Charles J. Gatchell; Janice K. Wiedenbeck; Elizabeth S. Walker

    1993-01-01

    An extensive data bank for red oak lumber that is compatible with most secondary manufacturing computer simulator tools is now available. Currently, the data bank contains 10,718 board feet in 1,578 boards. The National Hardwood Lumber Associations (NHLA) Special Kiln Dried Rule was used to grade the boards. The percentage of a boardâs surface measure contained in...

  16. Magnetic shape memory effect and highly mobile twin boundaries

    Czech Academy of Sciences Publication Activity Database

    Heczko, Oleg

    2014-01-01

    Roč. 30, č. 13 (2014), s. 1559-1578 ISSN 0267-0836 R&D Projects: GA ČR(CZ) GAP107/11/0391 Institutional support: RVO:68378271 Keywords : magnetic shape memory effect * ferromagnetic martensite * twinning * magnetically induced reorientation * reviews Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 0.995, year: 2014 http://dx.doi.org/10.1179/1743284714Y.0000000599

  17. Horizontal Gene Transfer from Diverse Bacteria to an Insect Genome Enables a Tripartite Nested Mealybug Symbiosis

    Czech Academy of Sciences Publication Activity Database

    Husník, Filip; Nikoh, N.; Koga, R.; Ross, L.; Duncan, R.P.; Fuije, M.; Tanaka, M.; Satoh, N.; Bachtrog, D.; Wilson, A.C.C.; von Dohlen, C.D.; Fukatsu, T.; McCutcheon, J.P.

    2013-01-01

    Roč. 153, č. 7 (2013), s. 1567-1578 ISSN 0092-8674 Grant - others:GA ČR(CZ) GAP505/10/1401; GA ČR(CZ) GA13-01878S Program:GA Institutional support: RVO:60077344 Keywords : intracellular bacteria * beta-proteobacteria * reduced genomes * host cell * evolution * endosymbionts * Wolbachia Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 33.116, year: 2013

  18. Image registration via optimization over disjoint image regions

    Science.gov (United States)

    Pitts, Todd; Hathaway, Simon; Karelitz, David B.; Sandusky, John; Laine, Mark Richard

    2018-02-06

    Technologies pertaining to registering a target image with a base image are described. In a general embodiment, the base image is selected from a set of images, and the target image is an image in the set of images that is to be registered to the base image. A set of disjoint regions of the target image is selected, and a transform to be applied to the target image is computed based on the optimization of a metric over the selected set of disjoint regions. The transform is applied to the target image so as to register the target image with the base image.

  19. Venus transits - A French view

    Science.gov (United States)

    Débarbat, Suzanne

    2005-04-01

    After a careful study of Mars observations obtained by Tycho Brahé (1546-1601), Kepler (1571-1630) discovered the now-called Kepler's third law. In 1627 he published his famous Tabulae Rudolphinae, a homage to his protector Rudolph II (1552-1612), tables (Kepler 1609, 1627) from which he predicted Mercury and Venus transits over the Sun. In 1629 Kepler published his Admonitio ad Astronomos Advertisement to Astronomers (Kepler 1630), Avertissement aux Astronomes in French Au sujet de phénomènes rares et étonnants de l'an 1631: l'incursion de Vénus et de Mercure sur le Soleil. This was the beginning of the interest of French astronomers, among many others, in such transits, mostly for Venus, the subject of this paper in which dates are given in the Gregorian calendar.

  20. Image processing with ImageJ

    CERN Document Server

    Pascau, Javier

    2013-01-01

    The book will help readers discover the various facilities of ImageJ through a tutorial-based approach.This book is targeted at scientists, engineers, technicians, and managers, and anyone who wishes to master ImageJ for image viewing, processing, and analysis. If you are a developer, you will be able to code your own routines after you have finished reading this book. No prior knowledge of ImageJ is expected.

  1. Ultrasonic image analysis and image-guided interventions.

    Science.gov (United States)

    Noble, J Alison; Navab, Nassir; Becher, H

    2011-08-06

    The fields of medical image analysis and computer-aided interventions deal with reducing the large volume of digital images (X-ray, computed tomography, magnetic resonance imaging (MRI), positron emission tomography and ultrasound (US)) to more meaningful clinical information using software algorithms. US is a core imaging modality employed in these areas, both in its own right and used in conjunction with the other imaging modalities. It is receiving increased interest owing to the recent introduction of three-dimensional US, significant improvements in US image quality, and better understanding of how to design algorithms which exploit the unique strengths and properties of this real-time imaging modality. This article reviews the current state of art in US image analysis and its application in image-guided interventions. The article concludes by giving a perspective from clinical cardiology which is one of the most advanced areas of clinical application of US image analysis and describing some probable future trends in this important area of ultrasonic imaging research.

  2. Imaging windows for long-term intravital imaging

    Science.gov (United States)

    Alieva, Maria; Ritsma, Laila; Giedt, Randy J; Weissleder, Ralph; van Rheenen, Jacco

    2014-01-01

    Intravital microscopy is increasingly used to visualize and quantitate dynamic biological processes at the (sub)cellular level in live animals. By visualizing tissues through imaging windows, individual cells (e.g., cancer, host, or stem cells) can be tracked and studied over a time-span of days to months. Several imaging windows have been developed to access tissues including the brain, superficial fascia, mammary glands, liver, kidney, pancreas, and small intestine among others. Here, we review the development of imaging windows and compare the most commonly used long-term imaging windows for cancer biology: the cranial imaging window, the dorsal skin fold chamber, the mammary imaging window, and the abdominal imaging window. Moreover, we provide technical details, considerations, and trouble-shooting tips on the surgical procedures and microscopy setups for each imaging window and explain different strategies to assure imaging of the same area over multiple imaging sessions. This review aims to be a useful resource for establishing the long-term intravital imaging procedure. PMID:28243510

  3. Improved image alignment method in application to X-ray images and biological images.

    Science.gov (United States)

    Wang, Ching-Wei; Chen, Hsiang-Chou

    2013-08-01

    Alignment of medical images is a vital component of a large number of applications throughout the clinical track of events; not only within clinical diagnostic settings, but prominently so in the area of planning, consummation and evaluation of surgical and radiotherapeutical procedures. However, image registration of medical images is challenging because of variations on data appearance, imaging artifacts and complex data deformation problems. Hence, the aim of this study is to develop a robust image alignment method for medical images. An improved image registration method is proposed, and the method is evaluated with two types of medical data, including biological microscopic tissue images and dental X-ray images and compared with five state-of-the-art image registration techniques. The experimental results show that the presented method consistently performs well on both types of medical images, achieving 88.44 and 88.93% averaged registration accuracies for biological tissue images and X-ray images, respectively, and outperforms the benchmark methods. Based on the Tukey's honestly significant difference test and Fisher's least square difference test tests, the presented method performs significantly better than all existing methods (P ≤ 0.001) for tissue image alignment, and for the X-ray image registration, the proposed method performs significantly better than the two benchmark b-spline approaches (P < 0.001). The software implementation of the presented method and the data used in this study are made publicly available for scientific communities to use (http://www-o.ntust.edu.tw/∼cweiwang/ImprovedImageRegistration/). cweiwang@mail.ntust.edu.tw.

  4. scikit-image: image processing in Python.

    Science.gov (United States)

    van der Walt, Stéfan; Schönberger, Johannes L; Nunez-Iglesias, Juan; Boulogne, François; Warner, Joshua D; Yager, Neil; Gouillart, Emmanuelle; Yu, Tony

    2014-01-01

    scikit-image is an image processing library that implements algorithms and utilities for use in research, education and industry applications. It is released under the liberal Modified BSD open source license, provides a well-documented API in the Python programming language, and is developed by an active, international team of collaborators. In this paper we highlight the advantages of open source to achieve the goals of the scikit-image library, and we showcase several real-world image processing applications that use scikit-image. More information can be found on the project homepage, http://scikit-image.org.

  5. scikit-image: image processing in Python

    Directory of Open Access Journals (Sweden)

    Stéfan van der Walt

    2014-06-01

    Full Text Available scikit-image is an image processing library that implements algorithms and utilities for use in research, education and industry applications. It is released under the liberal Modified BSD open source license, provides a well-documented API in the Python programming language, and is developed by an active, international team of collaborators. In this paper we highlight the advantages of open source to achieve the goals of the scikit-image library, and we showcase several real-world image processing applications that use scikit-image. More information can be found on the project homepage, http://scikit-image.org.

  6. Some Information Concerning Yom Tob Atias (Jeronimo de Vargas

    Directory of Open Access Journals (Sweden)

    Salomon, Herman P.

    2010-12-01

    Full Text Available The team of Ferrara editors was headed by two former New Christians: an entrepreneur, a native of Spain, and a Latin scholar from Portugal who in the introductions to variant editions of their scriptural production alternately call themselves by their Christian names Jeronimo de Vargas and Duarte Pinel, and by their Jewish names Yom Tob Atias and Abraham Usque. This “editorial schizophrenia” is reflected in the Italian archives. Whereas the historian Renata Segre’s researches have documented that Duarte Pinel and Abraham Usque were one and the same person, she was unable to find archival proof uniting Jeronimo de Vargas and Yom Tob Atias. The researcher Aron Leoni came up with a Latin notarial deed in the Ferrara archives wherein “Joantu Athias” is called “ptrem ac legitimum administratorum Hieronimi Vargas” and also the latter’s “patre et legitimo administrator.” He supposed “ptrem” to be an abbreviation of “procuratorem” and “patre” to mean father. Thus he concluded that Yom Tob Atias was the father of Jeronimo de Vargas. Close examination of the document and comparison with two others which have recently come to light reveal, however, the incontrovertible identity of Yom Tob Atias and Jeronimo de Vargas. We are dealing with a typical case of ex-Marrano heteronomy: a former New Christian maintaining a separate onomastic Christian identity alongside his Jewish one.

    El equipo de editores de Ferrara fue dirigido por dos antiguos cristianos nuevos, uno financiero, originario de España, y el otro, un latinista portugués. En las distintas introducciones a edición bíblica los dos se autodenominan alternativamente por sus nombres cristianos –Jerónimo de Vargas y Duarte Pinel– y por sus nombres judíos, Yom Tob Atías y Abraham Usque. Esta «esquizofrenia editorial» ha dejado huella en los archivos italianos. Mientras que las investigaciones de Renata Segre han documentado que Pinel y Usque eran la misma

  7. Automatic UAV Image Geo-Registration by Matching UAV Images to Georeferenced Image Data

    Directory of Open Access Journals (Sweden)

    Xiangyu Zhuo

    2017-04-01

    Full Text Available Recent years have witnessed the fast development of UAVs (unmanned aerial vehicles. As an alternative to traditional image acquisition methods, UAVs bridge the gap between terrestrial and airborne photogrammetry and enable flexible acquisition of high resolution images. However, the georeferencing accuracy of UAVs is still limited by the low-performance on-board GNSS and INS. This paper investigates automatic geo-registration of an individual UAV image or UAV image blocks by matching the UAV image(s with a previously taken georeferenced image, such as an individual aerial or satellite image with a height map attached or an aerial orthophoto with a DSM (digital surface model attached. As the biggest challenge for matching UAV and aerial images is in the large differences in scale and rotation, we propose a novel feature matching method for nadir or slightly tilted images. The method is comprised of a dense feature detection scheme, a one-to-many matching strategy and a global geometric verification scheme. The proposed method is able to find thousands of valid matches in cases where SIFT and ASIFT fail. Those matches can be used to geo-register the whole UAV image block towards the reference image data. When the reference images offer high georeferencing accuracy, the UAV images can also be geolocalized in a global coordinate system. A series of experiments involving different scenarios was conducted to validate the proposed method. The results demonstrate that our approach achieves not only decimeter-level registration accuracy, but also comparable global accuracy as the reference images.

  8. Titanium and Zirconium Complexes Containing the New 2,3-dimethyl-1,4-diphenylcyclopentadienyl Ligand. Synthesis, Characterization and Polymerization Behavior

    Czech Academy of Sciences Publication Activity Database

    Pinkas, Jiří; Horáček, Michal; Kubišta, Jiří; Gyepes, R.; Císařová, I.; Pirio, N.; Meunier, P.; Mach, Karel

    2004-01-01

    Roč. 689, - (2004), s. 1623-1630 ISSN 0022-328X R&D Projects: GA AV ČR KSK4050111 Keywords : titanocene * zircocene * polymerization Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 1.905, year: 2004

  9. An in situ Raman study of the intercalation of supercapacitor-type electrolyte into microcrystalline graphite

    International Nuclear Information System (INIS)

    Hardwick, Laurence J.; Hahn, Matthias; Ruch, Patrick; Holzapfel, Michael; Scheifele, Werner; Buqa, Hilmi; Krumeich, Frank; Novak, Petr; Koetz, Ruediger

    2006-01-01

    An initial Raman study on the effects of intercalation for aprotic electrolyte-based electrochemical double-layer capacitors (EDLCs) is reported. In situ Raman microscopy is employed in the study of the electrochemical intercalation of tetraethylammonium (Et 4 N + ) and tetrafluoroborate (BF 4 - ) into and out of microcrystalline graphite. During cyclic voltammetry experiments, the insertion of Et 4 N + into graphite for the negative electrode occurs at an onset potential of +1.0 V versus Li/Li + . For the positive electrode, BF 4 - was shown to intercalate above +4.3 V versus Li/Li + . The characteristic G-band doublet peak (E 2g2 (i) (1578 cm -1 ) and E 2g2 (b) (1600 cm -1 )) showed that various staged compounds were formed in both cases and the return of the single G-band (1578 cm -1 ) demonstrates that intercalation was fully reversible. The disappearance of the D-band (1329 cm -1 ) in intercalated graphite is also noted and when the intercalant is removed a more intense D-band reappears, indicating possible lattice damage. For cation intercalation, such irreversible changes of the graphite structure are confirmed by scanning electron microscopy (SEM)

  10. Markerless registration for image guided surgery. Preoperative image, intraoperative video image, and patient

    International Nuclear Information System (INIS)

    Kihara, Tomohiko; Tanaka, Yuko

    1998-01-01

    Real-time and volumetric acquisition of X-ray CT, MR, and SPECT is the latest trend of the medical imaging devices. A clinical challenge is to use these multi-modality volumetric information complementary on patient in the entire diagnostic and surgical processes. The intraoperative image and patient integration intents to establish a common reference frame by image in diagnostic and surgical processes. This provides a quantitative measure during surgery, for which we have been relied mostly on doctors' skills and experiences. The intraoperative image and patient integration involves various technologies, however, we think one of the most important elements is the development of markerless registration, which should be efficient and applicable to the preoperative multi-modality data sets, intraoperative image, and patient. We developed a registration system which integrates preoperative multi-modality images, intraoperative video image, and patient. It consists of a real-time registration of video camera for intraoperative use, a markerless surface sampling matching of patient and image, our previous works of markerless multi-modality image registration of X-ray CT, MR, and SPECT, and an image synthesis on video image. We think these techniques can be used in many applications which involve video camera like devices such as video camera, microscope, and image Intensifier. (author)

  11. Image processing and recognition for biological images.

    Science.gov (United States)

    Uchida, Seiichi

    2013-05-01

    This paper reviews image processing and pattern recognition techniques, which will be useful to analyze bioimages. Although this paper does not provide their technical details, it will be possible to grasp their main tasks and typical tools to handle the tasks. Image processing is a large research area to improve the visibility of an input image and acquire some valuable information from it. As the main tasks of image processing, this paper introduces gray-level transformation, binarization, image filtering, image segmentation, visual object tracking, optical flow and image registration. Image pattern recognition is the technique to classify an input image into one of the predefined classes and also has a large research area. This paper overviews its two main modules, that is, feature extraction module and classification module. Throughout the paper, it will be emphasized that bioimage is a very difficult target for even state-of-the-art image processing and pattern recognition techniques due to noises, deformations, etc. This paper is expected to be one tutorial guide to bridge biology and image processing researchers for their further collaboration to tackle such a difficult target. © 2013 The Author Development, Growth & Differentiation © 2013 Japanese Society of Developmental Biologists.

  12. IMAGE DESCRIPTIONS FOR SKETCH BASED IMAGE RETRIEVAL

    OpenAIRE

    SAAVEDRA RONDO, JOSE MANUEL; SAAVEDRA RONDO, JOSE MANUEL

    2008-01-01

    Due to the massive use of Internet together with the proliferation of media devices, content based image retrieval has become an active discipline in computer science. A common content based image retrieval approach requires that the user gives a regular image (e.g, a photo) as a query. However, having a regular image as query may be a serious problem. Indeed, people commonly use an image retrieval system because they do not count on the desired image. An easy alternative way t...

  13. Image formation and image analysis in electron microscopy

    International Nuclear Information System (INIS)

    Heel, M. van.

    1981-01-01

    This thesis covers various aspects of image formation and image analysis in electron microscopy. The imaging of relatively strong objects in partially coherent illumination, the coherence properties of thermionic emission sources and the detection of objects in quantum noise limited images are considered. IMAGIC, a fast, flexible and friendly image analysis software package is described. Intelligent averaging of molecular images is discussed. (C.F.)

  14. ImageSURF: An ImageJ Plugin for Batch Pixel-Based Image Segmentation Using Random Forests

    Directory of Open Access Journals (Sweden)

    Aidan O'Mara

    2017-11-01

    Full Text Available Image segmentation is a necessary step in automated quantitative imaging. ImageSURF is a macro-compatible ImageJ2/FIJI plugin for pixel-based image segmentation that considers a range of image derivatives to train pixel classifiers which are then applied to image sets of any size to produce segmentations without bias in a consistent, transparent and reproducible manner. The plugin is available from ImageJ update site http://sites.imagej.net/ImageSURF/ and source code from https://github.com/omaraa/ImageSURF. Funding statement: This research was supported by an Australian Government Research Training Program Scholarship.

  15. 21 CFR 177.1630 - Polyethylene phthalate polymers.

    Science.gov (United States)

    2010-04-01

    ... this chapter. (iv) Emulsifiers: Sodium dodecylbenzenesulfonate: As an adjuvant in the application of coatings to the base sheet or base polymer. Sodium lauryl sulfate: As an adjuvant in the application of coatings to the base sheet or base polymer. 2-Sulfoethyl methacrylate, sodium salt (CAS Reg. No. 1804-87-1...

  16. P16.30 4th ventricle glioblastoma

    Science.gov (United States)

    Unal, E.; Isik, S.; Gurbuz, M.; Kilic, K.

    2017-01-01

    Abstract Introduction: We present the 2nd case ever known in English literature describing a glioblastoma of the fourth ventricle originating from cerebellar peduncle. CASE DESCIPTION: A 66 years old woman was admitted to hospital with dizziness and nausea for four months. An MRI scan showed fourth ventricle mass. First impression was an ependymoma due to MRI scan characteristics. Results: A surgery was performed and histopathology revealed Grade IV glial tumor. Radiotherapy was done. CONCLUSION: This report suggests that GBM can mimic every tumor in the CNS. Surgery is the best option for these tumors not only for aggressive behaviour of glioblastoma but also to prevent hydrocephalus and associated symptoms.

  17. 29 CFR 1630.16 - Specific activities permitted.

    Science.gov (United States)

    2010-07-01

    ... history of any employee or applicant obtained from a test to determine the illegal use of drugs, except... of alcohol and drugs. A covered entity: (1) May prohibit the illegal use of drugs and the use of... alcohol or be engaging in the illegal use of drugs at the workplace; (3) May require that all employees...

  18. Wind-stilling in the light of wind speed measurements: the Czech experience

    Czech Academy of Sciences Publication Activity Database

    Brázdil, Rudolf; Valík, A.; Zahradníček, Pavel; Řezníčková, Ladislava; Tolasz, R.; Možný, M.

    2018-01-01

    Roč. 74 (2018), s. 131-143 ISSN 0936-577X R&D Projects: GA MŠk(CZ) LO1415; GA ČR(CZ) GA15-11805S Institutional support: RVO:86652079 Keywords : universal anemograph * vaisala wind-speed sensors * wind speed * homogenisation * wind stilling * Czech Republic Subject RIV: DG - Athmosphere Sciences, Meteorology OBOR OECD: Meteorology and atmospheric sciences Impact factor: 1.578, year: 2016

  19. Some problems on ordinary differential equations in Banach spaces

    Czech Academy of Sciences Publication Activity Database

    Hájek, Petr Pavel; Vivi, P.

    2010-01-01

    Roč. 104, č. 2 (2010), s. 245-255 ISSN 1578-7303 R&D Projects: GA AV ČR IAA100190801; GA ČR GA201/07/0394 Institutional research plan: CEZ:AV0Z10190503 Keywords : Banach space * ODE * Peano's theorem Subject RIV: BA - General Mathematics Impact factor: 0.400, year: 2010 http://link.springer.com/article/10.5052%2FRACSAM.2010.16

  20. Gul'ko, descriptive, and Gruenhage compact spaces

    Czech Academy of Sciences Publication Activity Database

    Fabian, Marián; Montesinos, V.; Zizler, Václav

    2010-01-01

    Roč. 104, č. 2 (2010), s. 201-220 ISSN 1578-7303 R&D Projects: GA AV ČR IAA100190901; GA AV ČR(CZ) IAA100190610 Institutional research plan: CEZ:AV0Z10190503 Keywords : Gul'ko * descriptive * fragmentable compact spaces * network Subject RIV: BA - General Mathematics Impact factor: 0.400, year: 2010 http://link.springer.com/article/10.5052%2FRACSAM.2010.14

  1. Drivers of treeline shift in different European mountains

    Czech Academy of Sciences Publication Activity Database

    Cudlín, Pavel; Klopčič, M.; Tognetti, R.; Máliš, F.; Alados, C. L.; Bebi, P.; Grunewald, K.; Zhiyanski, M.; Andonowski, V.; La Porta, N.; Bratanova-Doncheva, S.; Kachaunová, E.; Edwards-Jonášová, Magda; Ninot, J. M.; Rigling, A.; Hofgaard, A.; Hlásný, T.; Skalák, Petr; Wielgolaski, F. E.

    2017-01-01

    Roč. 73, 1-2 (2017), s. 135-150 ISSN 0936-577X R&D Projects: GA MŠk(CZ) LO1415; GA MŠk(CZ) LD14039 Institutional support: RVO:67179843 Keywords : Vegetation zone shift * Climate change * Climate models * Treeline ecotone * European mountains * Ecosystem services Subject RIV: EH - Ecology, Behaviour OBOR OECD: Environmental sciences (social aspects to be 5.7) Impact factor: 1.578, year: 2016

  2. Relationships between the evaporative stress index and winter wheat and spring barley yieldanomalies in the Czech Republic

    Czech Academy of Sciences Publication Activity Database

    Anderson, M.; Hain, C.; Jurečka, František; Trnka, Miroslav; Hlavinka, Petr; Dulaney, W.; Otkin, J.; Johnson, D.; Gao, F.

    2016-01-01

    Roč. 70, 2-3 (2016), s. 215-230 ISSN 0936-577X R&D Projects: GA MŠk(CZ) LO1415; GA MZe QJ1310123 Grant - others:EHP(CZ) EHP-CZ02-OV-1-014-2014 Program:CZ02 Institutional support: RVO:67179843 Keywords : evapotranspiration * drought * agriculture * remote sensing * crop yields * Czech Republic Subject RIV: EH - Ecology, Behaviour Impact factor: 1.578, year: 2016

  3. The Central European drought of 1947: causes and consequences, with particular reference to the Czech Lands

    Czech Academy of Sciences Publication Activity Database

    Brázdil, Rudolf; Raška, P.; Trnka, Miroslav; Zahradníček, Pavel; Valášek, H.; Dobrovolný, Petr; Řezníčková, Ladislava; Treml, P.; Stachoň, Z.

    2016-01-01

    Roč. 70, 2-3 (2016), s. 161-178 ISSN 0936-577X R&D Projects: GA MŠk(CZ) LO1415; GA MŠk(CZ) LD13030; GA ČR GA13-19831S Institutional support: RVO:67179843 Keywords : 1947 drought * Meteorological drought * Hydrological drought * Agricultural drought * Drought impact * Socio-economic responses * Czech Lands Subject RIV: DG - Athmosphere Sciences, Meteorology Impact factor: 1.578, year: 2016

  4. Spatial and temporal variability of mean daily wind speeds in the Czech Republic, 1961-2015

    Czech Academy of Sciences Publication Activity Database

    Brázdil, Rudolf; Zahradníček, Pavel; Řezníčková, Ladislava; Tolasz, R.; Štěpánek, Petr; Dobrovolný, Petr

    2017-01-01

    Roč. 72, č. 3 (2017), s. 197-216 ISSN 0936-577X R&D Projects: GA MŠk(CZ) LO1415; GA ČR(CZ) GA15-11805S Institutional support: RVO:67179843 Keywords : mean daily wind speed * spatial variability * temporal variability * wind stilling * Czech Republic Subject RIV: DG - Athmosphere Sciences, Meteorology OBOR OECD: Meteorology and atmospheric sciences Impact factor: 1.578, year: 2016

  5. Discharge pumped F/sub 2/ laser at 1580 A

    Energy Technology Data Exchange (ETDEWEB)

    Pummer, H; Hohla, K; Diegelmann, M; Reilly, J P

    1979-01-01

    By pumping mixtures of F/sub 2/ and He in a fast uv-preionized discharge laser emission at 1578 A, probably stemming from the /sup 3/PI/sub 2g/ ..-->.. /sup 3/PI/sub 2u/ transition in molecular fluorine have been obtained. Observed energy is 8.5 mJ in pulses of 15 ns half-width. First experimental results on laser performance and scalability are given.

  6. Modified electrophoretic and digestion conditions allow a simplified mass spectrometric evaluation of disulfide bonds

    Czech Academy of Sciences Publication Activity Database

    Pompach, Petr; Man, Petr; Kavan, Daniel; Hofbauerová, Kateřina; Kumar, Vinay; Bezouška, Karel; Havlíček, Vladimír; Novák, Petr

    2009-01-01

    Roč. 44, č. 11 (2009), s. 1571-1578 ISSN 1076-5174 R&D Projects: GA AV ČR KJB400200501; GA AV ČR IAA5020403; GA AV ČR KJB500200612; GA MŠk LC545; GA MŠk LC07017 Institutional research plan: CEZ:AV0Z50200510 Keywords : disulfide bond * cystamine * gel electrophoresis Subject RIV: CE - Biochemistry Impact factor: 3.411, year: 2009

  7. Fast processing of foreign fiber images by image blocking

    Directory of Open Access Journals (Sweden)

    Yutao Wu

    2014-08-01

    Full Text Available In the textile industry, it is always the case that cotton products are constitutive of many types of foreign fibers which affect the overall quality of cotton products. As the foundation of the foreign fiber automated inspection, image process exerts a critical impact on the process of foreign fiber identification. This paper presents a new approach for the fast processing of foreign fiber images. This approach includes five main steps, image block, image pre-decision, image background extraction, image enhancement and segmentation, and image connection. At first, the captured color images were transformed into gray-scale images; followed by the inversion of gray-scale of the transformed images ; then the whole image was divided into several blocks. Thereafter, the subsequent step is to judge which image block contains the target foreign fiber image through image pre-decision. Then we segment the image block via OSTU which possibly contains target images after background eradication and image strengthening. Finally, we connect those relevant segmented image blocks to get an intact and clear foreign fiber target image. The experimental result shows that this method of segmentation has the advantage of accuracy and speed over the other segmentation methods. On the other hand, this method also connects the target image that produce fractures therefore getting an intact and clear foreign fiber target image.

  8. A method of image improvement in three-dimensional imaging

    International Nuclear Information System (INIS)

    Suto, Yasuzo; Huang, Tewen; Furuhata, Kentaro; Uchino, Masafumi.

    1988-01-01

    In general, image interpolation is required when the surface configurations of such structures as bones and organs are three-dimensionally constructed from the multi-sliced images obtained by CT. Image interpolation is a processing method whereby an artificial image is inserted between two adjacent slices to make spatial resolution equal to slice resolution in appearance. Such image interpolation makes it possible to increase the image quality of the constructed three-dimensional image. In our newly-developed algorithm, we have converted the presently and subsequently sliced images to distance images, and generated the interpolation images from these two distance images. As a result, compared with the previous method, three-dimensional images with better image quality have been constructed. (author)

  9. The Glory of a Nearby Star

    Science.gov (United States)

    2001-08-01

    widespread occurrence of stellar coronae, Jürgen Schmitt and his collaborators at the University of Hamburg (Germany) asked themselves the natural question: "What about coronal line emission from other stars in the optical (visible) region of the spectrum ? Wouldn't it be a good idea to observe coronal emission from other stars with ground-based telescopes ? In any case, observations from the ground are easier to perform and are also more economical than from space" . This may be easy to say, but it is much harder to do. The main problem is the same as when observing the solar corona. The solar coronal emission lines in the visible region of the spectrum are always observed above the solar limb. If one were to try to detect these weak lines in front of the solar disk, they would "drown" in the strong background light from the solar 'surface' (the photosphere). The original discovery of coronal emission in 1869 was indeed obtained during a solar eclipse, when this strong light is completely blocked out by the Moon. However, current telescopes are unfortunately unable to block out the light from a stellar disk in a similar way in order to make its corona visible; the angular size of the disk is too small and the positional accuracy needed for such an observation is too high for it to be feasible with present techniques. The only way forward is then a direct attempt to detect the faint coronal emission against the much higher background of the stellar disk - and that is exactly why a very large telescope is needed for such an observational feat. Selecting the target star: CN Leonis ESO PR Photo 24b/01 ESO PR Photo 24b/01 [Preview - JPEG: 681 x 400 pix - 73k] [Normal - JPEG: 1362 x 800 pix - 616k] Caption : Images of the nearby, variable star CN Leonis , in which a coronal emission line has been observed with the UVES spectrograph at the 8.2-m VLT KUEYEN telescope. This star is relatively nearby (8 light-years) and moves about 5 arcsec/yr in the sky, approximately towards south

  10. Image processing with ImageJ

    NARCIS (Netherlands)

    Abramoff, M.D.; Magalhães, Paulo J.; Ram, Sunanda J.

    2004-01-01

    Wayne Rasband of NIH has created ImageJ, an open source Java-written program that is now at version 1.31 and is used for many imaging applications, including those that that span the gamut from skin analysis to neuroscience. ImageJ is in the public domain and runs on any operating system (OS).

  11. Compositional images from the Diffraction Enhanced Imaging technique

    International Nuclear Information System (INIS)

    Hasnah, M.O.; Zhong, Z.; Parham, C.; Zhang, H.; Chapman, D.

    2007-01-01

    Diffraction Enhanced Imaging (DEI) derives X-ray contrast from absorption, refraction, and extinction. While the refraction angle image of DEI represents the gradient of the projected mass density of the object, the absorption image measures the projected attenuation (μt)-bar of an object. Using a simple integral method it has been shown that a mass density image (ρt)-bar can be obtained from the refraction angle image. It then is a simple matter to develop a combinational image by dividing these two images to create a μ/ρ image. The μ/ρ is a fundamental property of a material and is therefore useful for identifying the composition of an object. In projection X-ray imaging the μ/ρ image identifies the integrated composition of the elements along the beam path. When applied to DEI computed tomography (CT), the image identifies the composition in each voxel. This method presents a new type of spectroscopy based in radiography. We present the method of obtaining the compositional image, the results of experiments in which we verify the method with known standards and an application of the method to breast cancer imaging

  12. Conductivity in Ag-As-S(Se,Te) chalcogenide glasses

    Czech Academy of Sciences Publication Activity Database

    Stehlík, Š.; Kolář, J.; Bartoš, M.; Vlček, Milan; Frumar, M.; Zima, Vítězslav; Wágner, T.

    2010-01-01

    Roč. 181, 37/38 (2010), s. 1625-1630 ISSN 0167-2738 Institutional research plan: CEZ:AV0Z40500505 Keywords : chalcogenide glasses * ionics conductivity * phase separation Subject RIV: CA - Inorganic Chemistry Impact factor: 2.496, year: 2010

  13. MAPLE activities and applications in gas sensors

    Czech Academy of Sciences Publication Activity Database

    Jelínek, Miroslav; Remsa, Jan; Kocourek, Tomáš; Kubešová, B.; Schůrek, J.; Myslík, V.

    2011-01-01

    Roč. 105, č. 3 (2011), 643-649 ISSN 0947-8396 Institutional research plan: CEZ:AV0Z10100522 Keywords : MAPLE * gas sensors * biomedicine * thin films Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.630, year: 2011

  14. Africa Insight - Vol 45, No 3 (2015)

    African Journals Online (AJOL)

    Enhancing the Leadership of Ward Councillors through Emotional Intelligence: The Case of the Buffalo City Metropolitan Municipality · EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. Nompendulo Mfene, Derek Taylor, 16-30 ...

  15. Mine vaatama!

    Index Scriptorium Estoniae

    2005-01-01

    Eesti Loodusmuuseumis 23. II-14. IV Kaupo Klooreni puust amulettide näitus, 16.-30. IV Tiit Leito fotonäitus "Metsamaastikud". Eesti Põllumajandusmuuseumis 7. III-15. IX Tan Silliksaare ja Tõnu Lingi fotonäitus "Maameeste maastikud"

  16. Evaluation of pulmonary emphysema by the fused image of CT image and ventilation SPECT image

    International Nuclear Information System (INIS)

    Okuda, Ituko; Maruno, Hiromasa; Mori, Kazuaki; Kohno, Tadashi; Kokubo, Takashi

    2007-01-01

    We evaluated pulmonary emphysema using a diagnostic device that could obtain a CT image, a ventilation single photon emission computed tomography (SPECT) image and a lung perfusion SPECT image in one examination. The fused image made from the CT image and SPECT image had very little position gap between images, and the precision was high. From the fused image, we were able to detect the areas in which emphysematous change was the most marked in the CT image, while the accumulation decrease was most remarkable in the ventilation SPECT image. Thus it was possible to obtain an accurate status of pulmonary emphysema, and our method was regarded as a useful technique. (author)

  17. Improving the Image Quality of Synthetic Transmit Aperture Ultrasound Images - Achieving Real-Time In-Vivo Imaging

    DEFF Research Database (Denmark)

    Gammelmark, Kim

    in-vivo experiments, showed, that TMS imaging can increase the SNR by as much as 17 dB compared to the traditional imaging techniques, which improves the in-vivo image quality to a highly competitive level. An in-vivo evaluation of convex array TMS imaging for abdominal imaging applications......-vivo imaging, and that the obtained image quality is highly competitive with the techniques applied in current medical ultrasound scanners. Hereby, the goals of the PhD have been successfully achieved.......Synthetic transmit aperture (STA) imaging has the potential to increase the image quality of medical ultrasound images beyond the levels obtained by conventional imaging techniques (linear, phased, and convex array imaging). Currently, however, in-vivo applications of STA imaging is limited...

  18. New Fellows and Honorary Fellow

    Indian Academy of Sciences (India)

    Specialization: Computational Chemistry, Non-Covalent Interactions, Biomolecular Simulations Address: Senior Principal Scientist, Chemical Laboratory, Central Leather Research Institute, Adyar, Chennai 600 020, T.N.. Contact: Office: (044) 2441 1630, (044) 2443 7150. Residence: (044) 2238 3031. Mobile: 98402 64151

  19. Nuclear medicine imaging instrumentations for molecular imaging

    International Nuclear Information System (INIS)

    Chung, Yong Hyun; Song, Tae Yong; Choi, Yong

    2004-01-01

    Small animal models are extensively utilized in the study of biomedical sciences. Current animal experiments and analysis are largely restricted to in vitro measurements and need to sacrifice animals to perform tissue or molecular analysis. This prevents researchers from observing in vivo the natural evolution of the process under study. Imaging techniques can provide repeatedly in vivo anatomic and molecular information noninvasively. Small animal imaging systems have been developed to assess biological process in experimental animals and increasingly employed in the field of molecular imaging studies. This review outlines the current developments in nuclear medicine imaging instrumentations including fused multi-modality imaging systems for small animal imaging

  20. Image registration of naval IR images

    Science.gov (United States)

    Rodland, Arne J.

    1996-06-01

    In a real world application an image from a stabilized sensor on a moving platform will not be 100 percent stabilized. There will always be a small unknown error in the stabilization due to factors such as dynamic deformations in the structure between sensor and reference Inertial Navigation Unit, servo inaccuracies, etc. For a high resolution imaging sensor this stabilization error causes the image to move several pixels in unknown direction between frames. TO be able to detect and track small moving objects from such a sensor, this unknown movement of the sensor image must be estimated. An algorithm that searches for land contours in the image has been evaluated. The algorithm searches for high contrast points distributed over the whole image. As long as moving objects in the scene only cover a small area of the scene, most of the points are located on solid ground. By matching the list of points from frame to frame, the movement of the image due to stabilization errors can be estimated and compensated. The point list is searched for points with diverging movement from the estimated stabilization error. These points are then assumed to be located on moving objects. Points assumed to be located on moving objects are gradually exchanged with new points located in the same area. Most of the processing is performed on the list of points and not on the complete image. The algorithm is therefore very fast and well suited for real time implementation. The algorithm has been tested on images from an experimental IR scanner. Stabilization errors were added artificially to the image such that the output from the algorithm could be compared with the artificially added stabilization errors.

  1. Image portion identification methods, image parsing methods, image parsing systems, and articles of manufacture

    Science.gov (United States)

    Lassahn, Gordon D.; Lancaster, Gregory D.; Apel, William A.; Thompson, Vicki S.

    2013-01-08

    Image portion identification methods, image parsing methods, image parsing systems, and articles of manufacture are described. According to one embodiment, an image portion identification method includes accessing data regarding an image depicting a plurality of biological substrates corresponding to at least one biological sample and indicating presence of at least one biological indicator within the biological sample and, using processing circuitry, automatically identifying a portion of the image depicting one of the biological substrates but not others of the biological substrates.

  2. Tomographic image reconstruction using training images

    DEFF Research Database (Denmark)

    Soltani, Sara; Andersen, Martin Skovgaard; Hansen, Per Christian

    2017-01-01

    We describe and examine an algorithm for tomographic image reconstruction where prior knowledge about the solution is available in the form of training images. We first construct a non-negative dictionary based on prototype elements from the training images; this problem is formulated within...

  3. Fulltext PDF

    Indian Academy of Sciences (India)

    Published online: 24 October 2012 ... language, and Juan Badiano was asked to translate it into. Latin. The Nahuatl original ..... plants. By the time the second edition appeared in 1630, Laet .... It had an important part to play. Herbal cures from.

  4. 75 FR 56533 - Wireless Telecommunications Bureau Postpones Auction of 218-219 MHz Service and Phase II 220 MHz...

    Science.gov (United States)

    2010-09-16

    ... FEDERAL COMMUNICATIONS COMMISSION [AU Docket No. 10-107; DA 10-1630] Wireless Telecommunications... Auction 89. FOR FURTHER INFORMATION CONTACT: Wireless Telecommunications Bureau, Auctions and Spectrum... by the Chief, Wireless Telecommunications Bureau pursuant to authority delegated by 47 CFR 0.131...

  5. Image quality of digital mammography images produced using wet and dry laser imaging systems

    International Nuclear Information System (INIS)

    Al Khalifah, K.; Brindhaban, A.; AlArfaj, R.; Jassim, O.

    2006-01-01

    Introduction: A study was carried out to compare the quality of digital mammographic images printed or processed by a wet laser imaging system and a dedicated mammographic dry laser imaging system. Material and methods: Digital images of a tissue equivalent breast phantom were obtained using a GE Senographe 2000D digital mammography system and different target/filter combinations of the X-ray tube. These images were printed on films using the Fuji FL-IM D wet laser imaging system and the Kodak DryView 8600 dry laser imaging system. The quality of images was assessed in terms of detectability of microcalcifications and simulated tumour masses by five radiologists. In addition, the contrast index and speed index of the two systems were measured using the step wedge in the phantom. The unpaired, unequal variance t-test was used to test any statistically significant differences. Results: There were no significant (p < 0.05) differences between the images printed using the two systems in terms of microcalcification and tumour mass detectability. The wet system resulted in slightly higher contrast index while the dry system showed significantly higher speed index. Conclusion: Both wet and dry laser imaging systems can produce mammography images of good quality on which 0.2 mm microcalcifications and 2 mm tumour masses can be detected. Dry systems are preferable due to the absence of wet chemical processing and solid or liquid chemical waste. The wet laser imaging systems, however, still represent a useful alternative to dry laser imaging systems for mammography studies

  6. Television Images and Adolescent Girls' Body Image Disturbance.

    Science.gov (United States)

    Botta, Renee A.

    1999-01-01

    Contributes to scholarship on the effects of media images on adolescents, using social-comparison theory and critical-viewing theory. Finds that media do have an impact on body-image disturbance. Suggests that body-image processing is the key to understanding how television images affect adolescent girls' body-image attitudes and behaviors. (SR)

  7. To Image...or Not to Image?

    Science.gov (United States)

    Bruley, Karina

    1996-01-01

    Provides a checklist of considerations for installing document image processing with an electronic document management system. Other topics include scanning; indexing; the image file life cycle; benefits of imaging; document-driven workflow; and planning for workplace changes like postsorting, creating a scanning room, redeveloping job tasks and…

  8. Edge-based correlation image registration for multispectral imaging

    Science.gov (United States)

    Nandy, Prabal [Albuquerque, NM

    2009-11-17

    Registration information for images of a common target obtained from a plurality of different spectral bands can be obtained by combining edge detection and phase correlation. The images are edge-filtered, and pairs of the edge-filtered images are then phase correlated to produce phase correlation images. The registration information can be determined based on these phase correlation images.

  9. ImageSURF MOAB2 Image Example

    OpenAIRE

    O'Mara, Aidan R; Collins, Jessica M; King, Anna E; Vickers, James C; Kirkcaldie, Matthew T K

    2017-01-01

    A set of 2000x2000 confocal fluorescence images of MOAB2-labelled cortex from APPswe/PS1dE9 mouse models of Alzheimer's disease, sparsely annotated pixel labels and reference segmentation examples. Pixels are annotated as signal (red 0xFFFF0000) and background (blue 0xFF0000FF). Images were captured as stitched 12-bit greyscale single-plane images and cropped to size. Image acquisition was performed at 561nm excitation and 615nm emission wavelengths using a Perkin Elmer Ultraview VOX ima...

  10. Transformation invariant image indexing and retrieval for image databases

    NARCIS (Netherlands)

    Gevers, Th.; Smeulders, A.W.M.

    1994-01-01

    This paper presents a novel design of an image database system which supports storage, indexing and retrieval of images by content. The image retrieval methodology is based on the observation that images can be discriminated by the presence of image objects and their spatial relations. Images in the

  11. Image processing of integrated video image obtained with a charged-particle imaging video monitor system

    International Nuclear Information System (INIS)

    Iida, Takao; Nakajima, Takehiro

    1988-01-01

    A new type of charged-particle imaging video monitor system was constructed for video imaging of the distributions of alpha-emitting and low-energy beta-emitting nuclides. The system can display not only the scintillation image due to radiation on the video monitor but also the integrated video image becoming gradually clearer on another video monitor. The distortion of the image is about 5% and the spatial resolution is about 2 line pairs (lp)mm -1 . The integrated image is transferred to a personal computer and image processing is performed qualitatively and quantitatively. (author)

  12. Hyperspectral small animal fluorescence imaging: spectral selection imaging

    Science.gov (United States)

    Leavesley, Silas; Jiang, Yanan; Patsekin, Valery; Hall, Heidi; Vizard, Douglas; Robinson, J. Paul

    2008-02-01

    Molecular imaging is a rapidly growing area of research, fueled by needs in pharmaceutical drug-development for methods for high-throughput screening, pre-clinical and clinical screening for visualizing tumor growth and drug targeting, and a growing number of applications in the molecular biology fields. Small animal fluorescence imaging employs fluorescent probes to target molecular events in vivo, with a large number of molecular targeting probes readily available. The ease at which new targeting compounds can be developed, the short acquisition times, and the low cost (compared to microCT, MRI, or PET) makes fluorescence imaging attractive. However, small animal fluorescence imaging suffers from high optical scattering, absorption, and autofluorescence. Much of these problems can be overcome through multispectral imaging techniques, which collect images at different fluorescence emission wavelengths, followed by analysis, classification, and spectral deconvolution methods to isolate signals from fluorescence emission. We present an alternative to the current method, using hyperspectral excitation scanning (spectral selection imaging), a technique that allows excitation at any wavelength in the visible and near-infrared wavelength range. In many cases, excitation imaging may be more effective at identifying specific fluorescence signals because of the higher complexity of the fluorophore excitation spectrum. Because the excitation is filtered and not the emission, the resolution limit and image shift imposed by acousto-optic tunable filters have no effect on imager performance. We will discuss design of the imager, optimizing the imager for use in small animal fluorescence imaging, and application of spectral analysis and classification methods for identifying specific fluorescence signals.

  13. Preparing diagnostic 3D images for image registration with planning CT images

    International Nuclear Information System (INIS)

    Tracton, Gregg S.; Miller, Elizabeth P.; Rosenman, Julian; Chang, Sha X.; Sailer, Scott; Boxwala, Azaz; Chaney, Edward L.

    1997-01-01

    Purpose: Pre-radiotherapy (pre-RT) tomographic images acquired for diagnostic purposes often contain important tumor and/or normal tissue information which is poorly defined or absent in planning CT images. Our two years of clinical experience has shown that computer-assisted 3D registration of pre-RT images with planning CT images often plays an indispensable role in accurate treatment volume definition. Often the only available format of the diagnostic images is film from which the original 3D digital data must be reconstructed. In addition, any digital data, whether reconstructed or not, must be put into a form suitable for incorporation into the treatment planning system. The purpose of this investigation was to identify all problems that must be overcome before this data is suitable for clinical use. Materials and Methods: In the past two years we have 3D-reconstructed 300 diagnostic images from film and digital sources. As a problem was discovered we built a software tool to correct it. In time we collected a large set of such tools and found that they must be applied in a specific order to achieve the correct reconstruction. Finally, a toolkit (ediScan) was built that made all these tools available in the proper manner via a pleasant yet efficient mouse-based user interface. Results: Problems we discovered included different magnifications, shifted display centers, non-parallel image planes, image planes not perpendicular to the long axis of the table-top (shearing), irregularly spaced scans, non contiguous scan volumes, multiple slices per film, different orientations for slice axes (e.g. left-right reversal), slices printed at window settings corresponding to tissues of interest for diagnostic purposes, and printing artifacts. We have learned that the specific steps to correct these problems, in order of application, are: Also, we found that fast feedback and large image capacity (at least 2000 x 2000 12-bit pixels) are essential for practical application

  14. Assessing the combined hazards of drought, soil erosion and local flooding on agricultural land: a Czech case study

    Czech Academy of Sciences Publication Activity Database

    Trnka, Miroslav; Semerádová, Daniela; Novotný, I.; Dumbrovský, M.; Drbal, K.; Pavlík, F.; Vopravil, J.; Štěpánková, P.; Vizina, A.; Balek, Jan; Hlavinka, Petr; Bartošová, Lenka; Žalud, Zdeněk

    2016-01-01

    Roč. 70, oct (2016), s. 231-249 ISSN 0936-577X R&D Projects: GA MŠk(CZ) LO1415; GA MZe(CZ) QJ1610072 Grant - others:EHP(CZ) EHP-CZ02-OV-1-014-2014 Program:CZ02 Institutional support: RVO:67179843 Keywords : Soil moisture * Sheet erosion * Ephemeral gully erosion * Fast-drying soil * Critical point * Vulnerability * Climate change Subject RIV: EH - Ecology, Behaviour Impact factor: 1.578, year: 2016

  15. Changing regional weather−crop yield relationships across Europe between 1901 and 2012

    Czech Academy of Sciences Publication Activity Database

    Trnka, Miroslav; Olesen, J. E.; Kersebaum, K. C.; Rötter, R. P.; Brázdil, Rudolf; Eitzinger, Josef; Jansen, S.; Skjelväg, A. O.; Peltonen-Sainio, P.; Hlavinka, Petr; Balek, J.; Eckersten, H.; Gobin, A.; Vučeti, V.; Dalla Marta, A.; Orlandini, S.; Alexandrov, V.; Semerádová, Daniela; Štěpánek, Petr; Svobodová, Eva; Rajdl, Kamil

    2016-01-01

    Roč. 70, 2-3 (2016), s. 195-214 ISSN 0936-577X R&D Projects: GA MŠk(CZ) LO1415; GA MŠk(CZ) LD13030; GA MZe QJ1310123; GA ČR GA13-19831S Institutional support: RVO:67179843 Keywords : Climatic trend * Weather–crop yield relationship * Wheat * Barley * Yield trend * Drought * Europe Subject RIV: DG - Athmosphere Sciences, Meteorology Impact factor: 1.578, year: 2016

  16. Physiological and biochemical responses to cold and drought in the rock-dwelling pulmonate snail, Chondrina avenacea

    Czech Academy of Sciences Publication Activity Database

    Košťál, Vladimír; Rozsypal, Jan; Pech, P.; Zahradníčková, Helena; Šimek, Petr

    2013-01-01

    Roč. 183, č. 6 (2013), s. 749-761 ISSN 0174-1578 R&D Projects: GA ČR GA206/07/0269; GA MZd(CZ) NT11513 Grant - others:GA JU(CZ) 04-062/2011/P Institutional support: RVO:60077344 Keywords : Mollusca * estivation * hibermation Subject RIV: ED - Physiology Impact factor: 2.530, year: 2013 http://link.springer.com/content/pdf/10.1007%2Fs00360-013-0749-0.pdf

  17. Naphthalene bisimides asymmetrically and symmetrically N-substituted with triarylamine - comparison of spectroscopic, electrochemical, electronic and self-assembly properties

    Czech Academy of Sciences Publication Activity Database

    Rybakiewicz, R.; Zapala, J.; Djurado, D.; Nowakowski, R.; Toman, Petr; Pfleger, Jiří; Verilhac, J.-M.; Zagorska, M.; Pron, A.

    2013-01-01

    Roč. 15, č. 5 (2013), s. 1578-1587 ISSN 1463-9076 R&D Projects: GA ČR(CZ) GAP205/10/2280; GA MŠk 7E10040 EU Projects: European Commission(XE) 247745 - FlexNet Institutional research plan: CEZ:AV0Z40500505 Institutional support: RVO:61389013 Keywords : naphthalene bisimides * density functional theory * electrochemistry Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 4.198, year: 2013

  18. Recent growth coherence in long-term oak (Quercus spp.) ring width chronologies in the Czech Republic

    Czech Academy of Sciences Publication Activity Database

    Dobrovolný, Petr; Rybníček, Michal; Büntgen, Ulf; Trnka, Miroslav; Brázdil, Rudolf; Stachoň, Z.; Prokop, O.; Kolář, Tomáš

    2016-01-01

    Roč. 70, 2-3 (2016), s. 133-141 ISSN 0936-577X R&D Projects: GA MŠk(CZ) LO1415; GA ČR GA13-04291S; GA MŠk(CZ) EE2.3.20.0248 Institutional support: RVO:67179843 Keywords : Tree-ring width chronology * Oak species * Tree-age structure * Site-specific conditions * Hydroclimate sensitivity * Czech Republic Subject RIV: DG - Athmosphere Sciences, Meteorology Impact factor: 1.578, year: 2016

  19. Maxillofacial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Larheim, T.A. [Oslo Univ. (Norway). Dept. of Maxillofacial Radiology; Westesson, P.L. [Univ. of Rochester School of Medicine and Dentistry, NY (United States). Div. of Diagnostic and Interventional Radiology

    2006-07-01

    Maxillofacial imaging has evolved dramatically over the past two decades with development of new cross-sectional imaging techniques. Traditional maxillofacial imaging was based on plain films and dental imaging. However, today's advanced imaging techniques with CT and MRI have only been partially implemented for maxillofacial questions. This book bridges the gap between traditional maxillofacial imaging and advanced medical imaging. We have applied CT and MRI to a variety of maxillofacial cases and these are illustrated with high-quality images and multiple planes. A comprehensive chapter on imaging anatomy is also included. This book is useful for oral and maxillofacial radiologists, oral and maxillofacial surgeons, dentists, radiologists, plastic surgeons, head and neck surgeons, and others that work with severe maxillofacial disorders. (orig.)

  20. Separation method of heavy-ion particle image from gamma-ray mixed images using an imaging plate

    CERN Document Server

    Yamadera, A; Ohuchi, H; Nakamura, T; Fukumura, A

    1999-01-01

    We have developed a separation method of alpha-ray and gamma-ray images using the imaging plate (IP). The IP from which the first image was read out by an image reader was annealed at 50 deg. C for 2 h in a drying oven and the second image was read out by the image reader. It was found out that an annealing ratio, k, which is defined as a ratio of the photo-stimulated luminescence (PSL) density at the first measurement to that at the second measurement, was different for alpha rays and gamma rays. By subtracting the second image multiplied by a factor of k from the first image, the alpha-ray image was separated from the alpha and gamma-ray mixed images. This method was applied to identify the images of helium, carbon and neon particles of high energies using the heavy-ion medical accelerator, HIMAC. (author)

  1. Characteristics of activated carbon remove sulfur particles against smog.

    Science.gov (United States)

    Ge, Shengbo; Liu, Zhenling; Furuta, Yuzo; Peng, Wanxi

    2017-09-01

    Sulfur particles, which could cause diseases, were the main powder of smog. And activated carbon had the very adsorption characteristics. Therefore, five sulfur particles were adsorbed by activated carbon and were analyzed by FT-IR. The optimal adsorption time were 120 min of Na 2 SO 3 , 120 min of Na 2 S 2 O 8 , 120 min of Na 2 SO 4 , 120 min of Fe 2 (SO 4 ) 3 and 120 min of S. FT-IR spectra showed that activated carbon had the eight characteristic absorption of S-S stretch, H 2 O stretch, O-H stretch, -C-H stretch, conjugated C 000000000000 000000000000 000000000000 111111111111 000000000000 111111111111 000000000000 000000000000 000000000000 O stretch or CC stretch, CH 2 bend, C-O stretch and acetylenic C-H bend vibrations at 3850 cm -1 , 3740 cm -1 , 3430 cm -1 , 2920 cm -1 , 1630 cm -1 , 1390 cm -1 , 1110 cm -1 and 600 cm -1 , respectively. For Na 2 SO 3 , the peaks at 2920 cm -1 , 1630 cm -1 , 1390 cm -1 and 1110 cm -1 achieved the maximum at 20 min. For Na 2 S 2 O 8 , the peaks at 3850 cm -1 , 3740 cm -1 and 2920 cm -1 achieved the maximum at 60 min. The peaks at 1390 cm -1 , 1110 cm -1 and 600 cm -1 achieved the maximum at 40 min. For Na 2 SO 4 , the peaks at 3430 cm -1 , 2920 cm -1 , 1630 cm -1 , 1390 cm -1 , 1110 cm -1 and 600 cm -1 achieved the maximum at 60 min. For Fe 2 (SO 4 ) 3 , the peaks at 1390 cm -1 , 1110 cm -1 and 600 cm -1 achieved the maximum at 20 min. For S, the peaks at 1630 cm -1 , 1390 cm -1 and 600 cm -1 achieved the maximum at 120 min. It provided that activated carbon could remove sulfur particles from smog air to restrain many anaphylactic diseases.

  2. Registration of angiographic image on real-time fluoroscopic image for image-guided percutaneous coronary intervention.

    Science.gov (United States)

    Kim, Dongkue; Park, Sangsoo; Jeong, Myung Ho; Ryu, Jeha

    2018-02-01

    In percutaneous coronary intervention (PCI), cardiologists must study two different X-ray image sources: a fluoroscopic image and an angiogram. Manipulating a guidewire while alternately monitoring the two separate images on separate screens requires a deep understanding of the anatomy of coronary vessels and substantial training. We propose 2D/2D spatiotemporal image registration of the two images in a single image in order to provide cardiologists with enhanced visual guidance in PCI. The proposed 2D/2D spatiotemporal registration method uses a cross-correlation of two ECG series in each image to temporally synchronize two separate images and register an angiographic image onto the fluoroscopic image. A guidewire centerline is then extracted from the fluoroscopic image in real time, and the alignment of the centerline with vessel outlines of the chosen angiographic image is optimized using the iterative closest point algorithm for spatial registration. A proof-of-concept evaluation with a phantom coronary vessel model with engineering students showed an error reduction rate greater than 74% on wrong insertion to nontarget branches compared to the non-registration method and more than 47% reduction in the task completion time in performing guidewire manipulation for very difficult tasks. Evaluation with a small number of experienced doctors shows a potentially significant reduction in both task completion time and error rate for difficult tasks. The total registration time with real procedure X-ray (angiographic and fluoroscopic) images takes [Formula: see text] 60 ms, which is within the fluoroscopic image acquisition rate of 15 Hz. By providing cardiologists with better visual guidance in PCI, the proposed spatiotemporal image registration method is shown to be useful in advancing the guidewire to the coronary vessel branches, especially those difficult to insert into.

  3. Multispectral image enhancement processing for microsat-borne imager

    Science.gov (United States)

    Sun, Jianying; Tan, Zheng; Lv, Qunbo; Pei, Linlin

    2017-10-01

    With the rapid development of remote sensing imaging technology, the micro satellite, one kind of tiny spacecraft, appears during the past few years. A good many studies contribute to dwarfing satellites for imaging purpose. Generally speaking, micro satellites weigh less than 100 kilograms, even less than 50 kilograms, which are slightly larger or smaller than the common miniature refrigerators. However, the optical system design is hard to be perfect due to the satellite room and weight limitation. In most cases, the unprocessed data captured by the imager on the microsatellite cannot meet the application need. Spatial resolution is the key problem. As for remote sensing applications, the higher spatial resolution of images we gain, the wider fields we can apply them. Consequently, how to utilize super resolution (SR) and image fusion to enhance the quality of imagery deserves studying. Our team, the Key Laboratory of Computational Optical Imaging Technology, Academy Opto-Electronics, is devoted to designing high-performance microsat-borne imagers and high-efficiency image processing algorithms. This paper addresses a multispectral image enhancement framework for space-borne imagery, jointing the pan-sharpening and super resolution techniques to deal with the spatial resolution shortcoming of microsatellites. We test the remote sensing images acquired by CX6-02 satellite and give the SR performance. The experiments illustrate the proposed approach provides high-quality images.

  4. Enhancement of image contrast in linacgram through image processing

    International Nuclear Information System (INIS)

    Suh, Hyun Suk; Shin, Hyun Kyo; Lee, Re Na

    2000-01-01

    Conventional radiation therapy portal images gives low contrast images. The purpose of this study was to enhance image contrast of a linacgram by developing a low--cost image processing method. Chest linacgram was obtained by irradiating humanoid phantom and scanned using Diagnostic-Pro scanner for image processing. Several types of scan method were used in scanning. These include optical density scan, histogram equalized scan, linear histogram based scan, linear histogram independent scan, linear optical density scan, logarithmic scan, and power square root scan. The histogram distribution of the scanned images were plotted and the ranges of the gray scale were compared among various scan types. The scanned images were then transformed to the gray window by pallette fitting method and the contrast of the reprocessed portal images were evaluated for image improvement. Portal images of patients were also taken at various anatomic sites and the images were processed by Gray Scale Expansion (GSE) method. The patient images were analyzed to examine the feasibility of using the GSE technique in clinic. The histogram distribution showed that minimum and maximum gray scale ranges of 3192 and 21940 were obtained when the image was scanned using logarithmic method and square root method, respectively. Out of 256 gray scale, only 7 to 30% of the steps were used. After expanding the gray scale to full range, contrast of the portal images were improved. Experiment performed with patient image showed that improved identification of organs were achieved by GSE in portal images of knee joint, head and neck, lung, and pelvis. Phantom study demonstrated that the GSE technique improved image contrast of a linacgram. This indicates that the decrease in image quality resulting from the dual exposure, could be improved by expanding the gray scale. As a result, the improved technique will make it possible to compare the digitally reconstructed radiographs (DRR) and simulation image for

  5. 75 FR 14427 - Gulf of Mexico Fishery Management Council (Council); Public Meetings

    Science.gov (United States)

    2010-03-25

    .... Stephen Bortone, Executive Director, Gulf of Mexico Fishery Management Council; telephone: 813- 348-1630... Reef Fish Scientific and Statistical Committee; discuss Options Paper for Amendment 32 Gag/Red Grouper... Statistical Committee Acceptable Biological Catch Control Rule Report; discuss the Options Paper for the...

  6. 76 FR 63919 - Whitestone Power and Communications; Notice of Technical Teleconference To Discuss Information...

    Science.gov (United States)

    2011-10-14

    ...). d. Name of Project: Microturbine Hydrokinetic River-In-Stream Energy Conversion Power Project (also.... Selvaggio, Whitestone Power and Communications, P.O. Box 1630, Delta Junction, Alaska 99737; (907) 895- 4938...: The proposed Microturbine Hydrokinetic River-In-Stream Energy Conversion Power Project would consist...

  7. 77 FR 8810 - Gulf of Mexico Fishery Management Council; Public Meetings

    Science.gov (United States)

    2012-02-15

    .... SUMMARY: The Gulf of Mexico Fishery Management Council (Council) will convene its Law Enforcement Advisory... East Beach Blvd., Gulfport, MS 39501. Council address: Gulf of Mexico Fishery Management Council, 2203..., Deputy Executive Director, Gulf of Mexico Fishery Management Council; telephone: (813) 348-1630...

  8. 75 FR 7444 - Gulf of Mexico Fishery Management Council; Public Meetings

    Science.gov (United States)

    2010-02-19

    .... SUMMARY: The Gulf of Mexico Fishery Management Council (Council) will convene its Law Enforcement Advisory...., Orange Beach, AL 36561. Council address: Gulf of Mexico Fishery Management Council, 2203 North Lois... Director, Gulf of Mexico Fishery Management Council; telephone: (813) 348-1630. SUPPLEMENTARY INFORMATION...

  9. Operadic categories and duoidal Deligne's conjecture

    Czech Academy of Sciences Publication Activity Database

    Batanin, M.; Markl, Martin

    2015-01-01

    Roč. 285, 5 November (2015), s. 1630-1687 ISSN 0001-8708 Institutional support: RVO:67985840 Keywords : operadic category * duoidal category * Deligne's conjecture Subject RIV: BA - General Mathematics Impact factor: 1.405, year: 2015 http://www.sciencedirect.com/science/article/pii/S0001870815002467

  10. BLOOD DONORS CAMPAIGN

    CERN Document Server

    Medical Service

    2002-01-01

    Tuesday 19 March 2002 in restaurant nr 2, from 9.00 to 16.30 hrs A blood donors campaign, organized by the Centre de Transfusion sanguine of Geneva If you already have a card giving your blood group, please bring this with you.

  11. Mirror-Image Equivalence and Interhemispheric Mirror-Image Reversal.

    Science.gov (United States)

    Corballis, Michael C

    2018-01-01

    Mirror-image confusions are common, especially in children and in some cases of neurological impairment. They can be a special impediment in activities such as reading and writing directional scripts, where mirror-image patterns (such as b and d ) must be distinguished. Treating mirror images as equivalent, though, can also be adaptive in the natural world, which carries no systematic left-right bias and where the same object or event can appear in opposite viewpoints. Mirror-image equivalence and confusion are natural consequences of a bilaterally symmetrical brain. In the course of learning, mirror-image equivalence may be established through a process of symmetrization, achieved through homotopic interhemispheric exchange in the formation of memory circuits. Such circuits would not distinguish between mirror images. Learning to discriminate mirror-image discriminations may depend either on existing brain asymmetries, or on extensive learning overriding the symmetrization process. The balance between mirror-image equivalence and mirror-image discrimination may nevertheless be precarious, with spontaneous confusions or reversals, such as mirror writing, sometimes appearing naturally or as a manifestation of conditions like dyslexia.

  12. Mirror-Image Equivalence and Interhemispheric Mirror-Image Reversal

    Directory of Open Access Journals (Sweden)

    Michael C. Corballis

    2018-04-01

    Full Text Available Mirror-image confusions are common, especially in children and in some cases of neurological impairment. They can be a special impediment in activities such as reading and writing directional scripts, where mirror-image patterns (such as b and d must be distinguished. Treating mirror images as equivalent, though, can also be adaptive in the natural world, which carries no systematic left-right bias and where the same object or event can appear in opposite viewpoints. Mirror-image equivalence and confusion are natural consequences of a bilaterally symmetrical brain. In the course of learning, mirror-image equivalence may be established through a process of symmetrization, achieved through homotopic interhemispheric exchange in the formation of memory circuits. Such circuits would not distinguish between mirror images. Learning to discriminate mirror-image discriminations may depend either on existing brain asymmetries, or on extensive learning overriding the symmetrization process. The balance between mirror-image equivalence and mirror-image discrimination may nevertheless be precarious, with spontaneous confusions or reversals, such as mirror writing, sometimes appearing naturally or as a manifestation of conditions like dyslexia.

  13. Continuous imaging space in three-dimensional integral imaging

    International Nuclear Information System (INIS)

    Zhang Lei; Yang Yong; Wang Jin-Gang; Zhao Xing; Fang Zhi-Liang; Yuan Xiao-Cong

    2013-01-01

    We report an integral imaging method with continuous imaging space. This method simultaneously reconstructs real and virtual images in the virtual mode, with a minimum gap that separates the entire imaging space into real and virtual space. Experimental results show that the gap is reduced to 45% of that in a conventional integral imaging system with the same parameters. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  14. Image reconstruction of dynamic infrared single-pixel imaging system

    Science.gov (United States)

    Tong, Qi; Jiang, Yilin; Wang, Haiyan; Guo, Limin

    2018-03-01

    Single-pixel imaging technique has recently received much attention. Most of the current single-pixel imaging is aimed at relatively static targets or the imaging system is fixed, which is limited by the number of measurements received through the single detector. In this paper, we proposed a novel dynamic compressive imaging method to solve the imaging problem, where exists imaging system motion behavior, for the infrared (IR) rosette scanning system. The relationship between adjacent target images and scene is analyzed under different system movement scenarios. These relationships are used to build dynamic compressive imaging models. Simulation results demonstrate that the proposed method can improve the reconstruction quality of IR image and enhance the contrast between the target and the background in the presence of system movement.

  15. Stereoscopic Integrated Imaging Goggles for Multimodal Intraoperative Image Guidance.

    Directory of Open Access Journals (Sweden)

    Christopher A Mela

    Full Text Available We have developed novel stereoscopic wearable multimodal intraoperative imaging and display systems entitled Integrated Imaging Goggles for guiding surgeries. The prototype systems offer real time stereoscopic fluorescence imaging and color reflectance imaging capacity, along with in vivo handheld microscopy and ultrasound imaging. With the Integrated Imaging Goggle, both wide-field fluorescence imaging and in vivo microscopy are provided. The real time ultrasound images can also be presented in the goggle display. Furthermore, real time goggle-to-goggle stereoscopic video sharing is demonstrated, which can greatly facilitate telemedicine. In this paper, the prototype systems are described, characterized and tested in surgeries in biological tissues ex vivo. We have found that the system can detect fluorescent targets with as low as 60 nM indocyanine green and can resolve structures down to 0.25 mm with large FOV stereoscopic imaging. The system has successfully guided simulated cancer surgeries in chicken. The Integrated Imaging Goggle is novel in 4 aspects: it is (a the first wearable stereoscopic wide-field intraoperative fluorescence imaging and display system, (b the first wearable system offering both large FOV and microscopic imaging simultaneously,

  16. Imaging systems in nuclear medicine and image evaluation

    International Nuclear Information System (INIS)

    Beck, R.; Charleston, D.; Metz, C.

    1980-01-01

    This project deals with imaging systems in nuclear medicine and image evaluation and is presented as four subprojects. The goal of the first subproject is to improve diagnositc image quality by development of a general computer code for optimizing collimator design. The second subproject deals with a secondary emission and fluorescence technique for thyroid scanning while the third subproject emphasizes the need for more sophisticated image processing systems such as coherent optical spatial filtering systems and digital image processing. The fourth subproject presents a new approach for processing image data by taking into account the energy of each detected gamma-ray photon

  17. Imaging sciences workshop

    Energy Technology Data Exchange (ETDEWEB)

    Candy, J.V.

    1994-11-15

    This workshop on the Imaging Sciences sponsored by Lawrence Livermore National Laboratory contains short abstracts/articles submitted by speakers. The topic areas covered include the following: Astronomical Imaging; biomedical imaging; vision/image display; imaging hardware; imaging software; Acoustic/oceanic imaging; microwave/acoustic imaging; computed tomography; physical imaging; imaging algorithms. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.

  18. PC image processing

    International Nuclear Information System (INIS)

    Hwa, Mok Jin Il; Am, Ha Jeng Ung

    1995-04-01

    This book starts summary of digital image processing and personal computer, and classification of personal computer image processing system, digital image processing, development of personal computer and image processing, image processing system, basic method of image processing such as color image processing and video processing, software and interface, computer graphics, video image and video processing application cases on image processing like satellite image processing, color transformation of image processing in high speed and portrait work system.

  19. Lossy image compression for digital medical imaging systems

    Science.gov (United States)

    Wilhelm, Paul S.; Haynor, David R.; Kim, Yongmin; Nelson, Alan C.; Riskin, Eve A.

    1990-07-01

    Image compression at rates of 10:1 or greater could make PACS much more responsive and economically attractive. This paper describes a protocol for subjective and objective evaluation of the fidelity of compressed/decompressed images to the originals and presents the results ofits application to four representative and promising compression methods. The methods examined are predictive pruned tree-structured vector quantization, fractal compression, the discrete cosine transform with equal weighting of block bit allocation, and the discrete cosine transform with human visual system weighting of block bit allocation. Vector quantization is theoretically capable of producing the best compressed images, but has proven to be difficult to effectively implement. It has the advantage that it can reconstruct images quickly through a simple lookup table. Disadvantages are that codebook training is required, the method is computationally intensive, and achieving the optimum performance would require prohibitively long vector dimensions. Fractal compression is a relatively new compression technique, but has produced satisfactory results while being computationally simple. It is fast at both image compression and image reconstruction. Discrete cosine iransform techniques reproduce images well, but have traditionally been hampered by the need for intensive computing to compress and decompress images. A protocol was developed for side-by-side observer comparison of reconstructed images with originals. Three 1024 X 1024 CR (Computed Radiography) images and two 512 X 512 X-ray CT images were viewed at six bit rates (0.2, 0.4, 0.6, 0.9, 1.2, and 1.5 bpp for CR, and 1.0, 1.3, 1.6, 1.9, 2.2, 2.5 bpp for X-ray CT) by nine radiologists at the University of Washington Medical Center. The CR images were viewed on a Pixar II Megascan (2560 X 2048) monitor and the CT images on a Sony (1280 X 1024) monitor. The radiologists' subjective evaluations of image fidelity were compared to

  20. Image Analysis for X-ray Imaging of Food

    DEFF Research Database (Denmark)

    Einarsdottir, Hildur

    for quality and safety evaluation of food products. In this effort the fields of statistics, image analysis and statistical learning are combined, to provide analytical tools for determining the aforementioned food traits. The work demonstrated includes a quantitative analysis of heat induced changes......X-ray imaging systems are increasingly used for quality and safety evaluation both within food science and production. They offer non-invasive and nondestructive penetration capabilities to image the inside of food. This thesis presents applications of a novel grating-based X-ray imaging technique...... and defect detection in food. Compared to the complex three dimensional analysis of microstructure, here two dimensional images are considered, making the method applicable for an industrial setting. The advantages obtained by grating-based imaging are compared to conventional X-ray imaging, for both foreign...

  1. Image Processing and Features Extraction of Fingerprint Images ...

    African Journals Online (AJOL)

    To demonstrate the importance of the image processing of fingerprint images prior to image enrolment or comparison, the set of fingerprint images in databases (a) and (b) of the FVC (Fingerprint Verification Competition) 2000 database were analyzed using a features extraction algorithm. This paper presents the results of ...

  2. Image quality at synthetic brain magnetic resonance imaging in children

    Energy Technology Data Exchange (ETDEWEB)

    Lee, So Mi; Cho, Seung Hyun; Kim, Won Hwa; Kim, Hye Jung [Kyungpook National University Hospital, Department of Radiology, Daegu (Korea, Republic of); Choi, Young Hun; Cheon, Jung-Eun; Kim, In-One [Seoul National University College of Medicine, Department of Radiology and Institute of Radiation Medicine, Seoul (Korea, Republic of); Cho, Hyun-Hae [Ewha Womans University Mokdong Hospital, Department of Radiology, Seoul (Korea, Republic of); You, Sun-Kyoung [Chungnam National University Hospital, Department of Radiology, Daejeon (Korea, Republic of); Park, Sook-Hyun [Kyungpook National University Hospital, Department of Pediatrics, Daegu (Korea, Republic of); Hwang, Moon Jung [GE Healthcare, MR Applications and Workflow, Seoul (Korea, Republic of)

    2017-11-15

    The clinical application of the multi-echo, multi-delay technique of synthetic magnetic resonance imaging (MRI) generates multiple sequences in a single acquisition but has mainly been used in adults. To evaluate the image quality of synthetic brain MR in children compared with that of conventional images. Twenty-nine children (median age: 6 years, range: 0-16 years) underwent synthetic and conventional imaging. Synthetic (T2-weighted, T1-weighted and fluid-attenuated inversion recovery [FLAIR]) images with settings matching those of the conventional images were generated. The overall image quality, gray/white matter differentiation, lesion conspicuity and image degradations were rated on a 5-point scale. The relative contrasts were assessed quantitatively and acquisition times for the two imaging techniques were compared. Synthetic images were inferior due to more pronounced image degradations; however, there were no significant differences for T1- and T2-weighted images in children <2 years old. The quality of T1- and T2-weighted images were within the diagnostically acceptable range. FLAIR images showed greatly reduced quality. Gray/white matter differentiation was comparable or better in synthetic T1- and T2-weighted images, but poorer in FLAIR images. There was no effect on lesion conspicuity. Synthetic images had equal or greater relative contrast. Acquisition time was approximately two-thirds of that for conventional sequences. Synthetic T1- and T2-weighted images were diagnostically acceptable, but synthetic FLAIR images were not. Lesion conspicuity and gray/white matter differentiation were comparable to conventional MRI. (orig.)

  3. Luminescence imaging using radionuclides: a potential application in molecular imaging

    International Nuclear Information System (INIS)

    Park, Jeong Chan; Il An, Gwang; Park, Se-Il; Oh, Jungmin; Kim, Hong Joo; Su Ha, Yeong; Wang, Eun Kyung; Min Kim, Kyeong; Kim, Jung Young; Lee, Jaetae; Welch, Michael J.; Yoo, Jeongsoo

    2011-01-01

    Introduction: Nuclear and optical imaging are complementary in many aspects and there would be many advantages when optical imaging probes are prepared using radionuclides rather than classic fluorophores, and when nuclear and optical dual images are obtained using single imaging probe. Methods: The luminescence intensities of various radionuclides having different decay modes have been assayed using luminescence imaging and in vitro luminometer. Radioiodinated Herceptin was injected into a tumor-bearing mouse, and luminescence and microPET images were obtained. The plant dipped in [ 32 P]phosphate solution was scanned in luminescence mode. Radio-TLC plate was also imaged in the same imaging mode. Results: Radionuclides emitting high energy β + /β - particles showed higher luminescence signals. NIH3T6.7 tumors were detected in both optical and nuclear imaging. The uptake of [ 32 P]phosphate in plant was easily followed by luminescence imaging. Radio-TLC plate was visualized and radiochemical purity was quantified using luminescence imaging. Conclusion: Many radionuclides with high energetic β + or β - particles during decay were found to be imaged in luminescence mode due mainly to Cerenkov radiation. 'Cerenkov imaging' provides a new optical imaging platform and an invaluable bridge between optical and nuclear imaging. New optical imaging probes could be easily prepared using well-established radioiodination methods. Cerenkov imaging will have more applications in the research field of plant science and autoradiography.

  4. Color image guided depth image super resolution using fusion filter

    Science.gov (United States)

    He, Jin; Liang, Bin; He, Ying; Yang, Jun

    2018-04-01

    Depth cameras are currently playing an important role in many areas. However, most of them can only obtain lowresolution (LR) depth images. Color cameras can easily provide high-resolution (HR) color images. Using color image as a guide image is an efficient way to get a HR depth image. In this paper, we propose a depth image super resolution (SR) algorithm, which uses a HR color image as a guide image and a LR depth image as input. We use the fusion filter of guided filter and edge based joint bilateral filter to get HR depth image. Our experimental results on Middlebury 2005 datasets show that our method can provide better quality in HR depth images both numerically and visually.

  5. Epidural fat image in lumbar magnetic resonance image

    International Nuclear Information System (INIS)

    Nishijima, Yuichiro; Yamasaki, Yasuo; Higashida, Norihiko; Okada, Masato

    1993-01-01

    To examine epidural fat images, lumbar magnetic resonance (MR) images were retrospectively reviewed in a total of 103 patients with surgically proven lumbar disc herniation (DH, n=57) and lumbar canal stenosis (LCS, n=46). Epidural fat images consisted of middorsal epidural fat (MDF), paramedian ventral fat (PVF) and intervertebral foraminal fat (IFF) ones. In the group of DH, the thickness of MDF image did not correlate with that of subcutaneous fat, suggesting that epidural fat was not affected by body fat. From the pathophysiological point of view, decrease and disappearance of MDF images correlated with compression of the epidural canal. Decrease and disappearance of PVF images lead to suspicious compression of the traversing root. In addition, asymmetrical PVF images were useful for the bilateral diagnosis of herniation. Abnormal findings of IFF images were suggestive of compression of the exiting nerve root at the intervertebral foramen. This was also seen frequently at the non-responsible level in patients over the age of 50. Degenerative and sequentrated spondylolistheses in the group of LCS were more frequently associated with a higher incidence of abnormal findings of IFF images, suggesting the presence of existing nerve root compression. (N.K.)

  6. The application of non-Saccharomyces yeast in fermentations with limited aeration as a strategy for the production of wine with reduced alcohol content.

    Science.gov (United States)

    Contreras, A; Hidalgo, C; Schmidt, S; Henschke, P A; Curtin, C; Varela, C

    2015-07-16

    High alcohol concentrations reduce the complexity of wine sensory properties. In addition, health and economic drivers have the wine industry actively seeking technologies that facilitate the production of wines with lower alcohol content. One of the simplest approaches to achieve this aim would be the use of wine yeast strains which are less efficient at transforming grape sugars into ethanol, however commercially available wine yeasts produce very similar ethanol yields. Non-conventional yeast, in particular non-Saccharomyces species, have shown potential for producing wines with lower alcohol content. These yeasts are naturally present in the early stages of fermentation but in general are not capable of completing alcoholic fermentation. We have evaluated 48 non-Saccharomyces isolates to identify strains that, with limited aeration and in sequential inoculation regimes with S. cerevisiae, could be used for the production of wine with lower ethanol concentration. Two of these, Torulaspora delbrueckii AWRI1152 and Zygosaccharomyces bailii AWRI1578, enabled the production of wine with reduced ethanol concentration under limited aerobic conditions. Depending on the aeration regime T. delbrueckii AWRI1152 and Z. bailii AWRI1578 showed a reduction in ethanol concentration of 1.5% (v/v) and 2.0% (v/v) respectively, compared to the S. cerevisiae anaerobic control. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Improving image quality in portal venography with spectral CT imaging

    International Nuclear Information System (INIS)

    Zhao, Li-qin; He, Wen; Li, Jian-ying; Chen, Jiang-hong; Wang, Ke-yang; Tan, Li

    2012-01-01

    Objective: To investigate the effect of energy spectral CT on the image quality of CT portal venography in cirrhosis patients. Materials and methods: 30 portal hypertension patients underwent spectral CT examination using a single-tube, fast dual tube voltage switching technique. 101 sets of monochromatic images were generated from 40 keV to 140 keV. Image noise and contrast-to-noise ratio (CNR) for portal veins from the monochromatic images were measured. An optimal monochromatic image set was selected for obtaining the best CNR for portal veins. The image noise and CNR of the intra-hepatic portal vein and extra-hepatic main stem at the selected monochromatic level were compared with those from the conventional polychromatic images. Image quality was also assessed and compared. Results: The monochromatic images at 51 keV were found to provide the best CNR for both the intra-hepatic and extra-hepatic portal veins. At this energy level, the monochromatic images had about 100% higher CNR than the polychromatic images with a moderate 30% noise increase. The qualitative image quality assessment was also statistically higher with monochromatic images at 51 keV. Conclusion: Monochromatic images at 51 keV for CT portal venography could improve CNR for displaying hepatic portal veins and improve the overall image quality.

  8. Improving image quality in portal venography with spectral CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Li-qin, E-mail: zhaolqzr@sohu.com [Department of Radiology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing,100050 (China); He, Wen, E-mail: hewen1724@sina.com [Department of Radiology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing,100050 (China); Li, Jian-ying, E-mail: jianying.li@med.ge.com [CT Advanced Application and Research, GE Healthcare, 100176 China (China); Chen, Jiang-hong, E-mail: chenjianghong1973@hotmail.com [Department of Radiology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing,100050 (China); Wang, Ke-yang, E-mail: ke7ke@sina.com [Department of Radiology, Beijing Friendship Hospital Affiliated to Capital Medical University, Beijing,100050 (China); Tan, Li, E-mail: Litan@ge.com [CT product, GE Healthcare, 100176 China (China)

    2012-08-15

    Objective: To investigate the effect of energy spectral CT on the image quality of CT portal venography in cirrhosis patients. Materials and methods: 30 portal hypertension patients underwent spectral CT examination using a single-tube, fast dual tube voltage switching technique. 101 sets of monochromatic images were generated from 40 keV to 140 keV. Image noise and contrast-to-noise ratio (CNR) for portal veins from the monochromatic images were measured. An optimal monochromatic image set was selected for obtaining the best CNR for portal veins. The image noise and CNR of the intra-hepatic portal vein and extra-hepatic main stem at the selected monochromatic level were compared with those from the conventional polychromatic images. Image quality was also assessed and compared. Results: The monochromatic images at 51 keV were found to provide the best CNR for both the intra-hepatic and extra-hepatic portal veins. At this energy level, the monochromatic images had about 100% higher CNR than the polychromatic images with a moderate 30% noise increase. The qualitative image quality assessment was also statistically higher with monochromatic images at 51 keV. Conclusion: Monochromatic images at 51 keV for CT portal venography could improve CNR for displaying hepatic portal veins and improve the overall image quality.

  9. Image fusion between whole body FDG PET images and whole body MRI images using a full-automatic mutual information-based multimodality image registration software

    International Nuclear Information System (INIS)

    Uchida, Yoshitaka; Nakano, Yoshitada; Fujibuchi, Toshiou; Isobe, Tomoko; Kazama, Toshiki; Ito, Hisao

    2006-01-01

    We attempted image fusion between whole body PET and whole body MRI of thirty patients using a full-automatic mutual information (MI) -based multimodality image registration software and evaluated accuracy of this method and impact of the coregistrated imaging on diagnostic accuracy. For 25 of 30 fused images in body area, translating gaps were within 6 mm in all axes and rotating gaps were within 2 degrees around all axes. In head and neck area, considerably much gaps caused by difference of head inclination at imaging occurred in 16 patients, however these gaps were able to decrease by fused separately. In 6 patients, diagnostic accuracy using PET/MRI fused images was superior compared by PET image alone. This work shows that whole body FDG PET images and whole body MRI images can be automatically fused using MI-based multimodality image registration software accurately and this technique can add useful information when evaluating FDG PET images. (author)

  10. Fluorescence Image Segmentation by using Digitally Reconstructed Fluorescence Images

    OpenAIRE

    Blumer, Clemens; Vivien, Cyprien; Oertner, Thomas G; Vetter, Thomas

    2011-01-01

    In biological experiments fluorescence imaging is used to image living and stimulated neurons. But the analysis of fluorescence images is a difficult task. It is not possible to conclude the shape of an object from fluorescence images alone. Therefore, it is not feasible to get good manual segmented nor ground truth data from fluorescence images. Supervised learning approaches are not possible without training data. To overcome this issues we propose to synthesize fluorescence images and call...

  11. 2278-IJBCS-Article-Nanfack Minkeu Ferdinand

    African Journals Online (AJOL)

    hp

    Available online at http://ajol.info/index.php/ijbcs. Int. J. Biol. Chem. Sci. 9(3): 1630-1643, ..... (Ferrer, 2003; Pimentel, 2005; Meeker et al.,. 2008; Zeinab et ..... Collado A, Stevenson J, Scaife S,. Dafa'alla T, Fu G, .... Kisinza W, David J-P. 2014.

  12. 77 FR 4282 - Gulf of Mexico Fishery Management Council; Public Meeting

    Science.gov (United States)

    2012-01-27

    ... meeting. SUMMARY: The Gulf of Mexico Fishery Management Council will convene a meeting of the Shrimp Stock... Laboratory, 4700 Avenue U, Galveston, TX 77551-5997. Council address: Gulf of Mexico Fishery Management... Management Council; telephone: (813) 348-1630. SUPPLEMENTARY INFORMATION: The Shrimp Stock Assessment Review...

  13. 77 FR 27757 - Whitestone Power and Communications; Notice of Application Accepted for Filing, Soliciting...

    Science.gov (United States)

    2012-05-11

    ... Communications. e. Name of Project: Whitestone Poncelet River-In-Stream-Energy- Conversion Project (also known as the Microturbine Hydrokinetic River- In-Stream-Energy-Conversion Project) f. Location: The proposed.... Selvaggio, Whitestone Power and Communications, P.O. Box 1630, Delta Junction, Alaska 99737; phone: (907...

  14. 77 FR 21977 - Whitestone Power and Communications; Notice Concluding Pre-Filing Process and Approving Process...

    Science.gov (United States)

    2012-04-12

    ... Communications (Whitestone). e. Name of Project: Microturbine Hydrokinetic River-In-Stream Energy Conversion.... Applicant Contact: Steven M. Selvaggio, Whitestone Power and Communications, P.O. Box 1630, Delta Junction... Microturbine Hydrokinetic River-In-Stream Energy Conversion Power Project would consist of: (1) A 12-foot-wide...

  15. 76 FR 37064 - Gulf of Mexico Fishery Management Council (Council); Public Meeting

    Science.gov (United States)

    2011-06-24

    ... meeting. SUMMARY: The Gulf of Mexico Fishery Management Council will convene a public meeting via webinar... meeting will be held via webinar. Council address: Gulf of Mexico Fishery Management Council, 2203 North... Executive Director, Gulf of Mexico Fishery Management Council; telephone: (813) 348-1630. SUPPLEMENTARY...

  16. 78 FR 33070 - Gulf of Mexico Fishery Management Council; Public Meetings

    Science.gov (United States)

    2013-06-03

    .... SUMMARY: The Gulf of Mexico Fishery Management Council (Council) will convene a public meeting. DATES: The...; telephone: (850) 433-3336. Council address: Gulf of Mexico Fishery Management Council, 2203 North Lois... Director, Gulf of Mexico Fishery Management Council; telephone: (813) 348-1630. SUPPLEMENTARY INFORMATION...

  17. Differential scanning calorimetric and powder X-ray diffraction ...

    Indian Academy of Sciences (India)

    18) ... cells with no nuclei and cell organelles.1 The main composition of the ... properties of these molecules in a systematic manner. Most useful in this .... 1630. D Sivaramakrishna and Musti J Swamy. 40. 50. 60. 70. 80. 90. 40. 50. 60. 70. 80. 90.

  18. Statistical and regression analyses of detected extrasolar systems

    Czech Academy of Sciences Publication Activity Database

    Pintr, Pavel; Peřinová, V.; Lukš, A.; Pathak, A.

    2013-01-01

    Roč. 75, č. 1 (2013), s. 37-45 ISSN 0032-0633 Institutional support: RVO:61389021 Keywords : Exoplanets * Kepler candidates * Regression analysis Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 1.630, year: 2013 http://www.sciencedirect.com/science/article/pii/S0032063312003066

  19. “health benefits” of fruit

    African Journals Online (AJOL)

    be based on the total polyphenol content provided by the “5-a-day” portions of fruit .... For instance, many of the radical species utilised in these assays ... of selected foods.16,30 The data generated by various TAC assays are also employed ...

  20. Medical Image Tamper Detection Based on Passive Image Authentication.

    Science.gov (United States)

    Ulutas, Guzin; Ustubioglu, Arda; Ustubioglu, Beste; V Nabiyev, Vasif; Ulutas, Mustafa

    2017-12-01

    Telemedicine has gained popularity in recent years. Medical images can be transferred over the Internet to enable the telediagnosis between medical staffs and to make the patient's history accessible to medical staff from anywhere. Therefore, integrity protection of the medical image is a serious concern due to the broadcast nature of the Internet. Some watermarking techniques are proposed to control the integrity of medical images. However, they require embedding of extra information (watermark) into image before transmission. It decreases visual quality of the medical image and can cause false diagnosis. The proposed method uses passive image authentication mechanism to detect the tampered regions on medical images. Structural texture information is obtained from the medical image by using local binary pattern rotation invariant (LBPROT) to make the keypoint extraction techniques more successful. Keypoints on the texture image are obtained with scale invariant feature transform (SIFT). Tampered regions are detected by the method by matching the keypoints. The method improves the keypoint-based passive image authentication mechanism (they do not detect tampering when the smooth region is used for covering an object) by using LBPROT before keypoint extraction because smooth regions also have texture information. Experimental results show that the method detects tampered regions on the medical images even if the forged image has undergone some attacks (Gaussian blurring/additive white Gaussian noise) or the forged regions are scaled/rotated before pasting.

  1. Astrometrically registered simultaneous observations of the 22 GHz H{sub 2}O and 43 GHz SiO masers toward R Leonis Minoris using KVN and source/frequency phase referencing

    Energy Technology Data Exchange (ETDEWEB)

    Dodson, Richard; Rioja, María J.; Jung, Tae-Hyun; Sohn, Bong-Won; Byun, Do-Young; Cho, Se-Hyung; Lee, Sang-Sung; Kim, Jongsoo; Kim, Kee-Tae; Oh, Chung-Sik; Han, Seog-Tae; Je, Do-Heung; Chung, Moon-Hee; Wi, Seog-Oh; Kang, Jiman; Lee, Jung-Won; Chung, Hyunsoo; Kim, Hyo-Ryoung; Kim, Hyun-Goo; Lee, Chang-Hoon, E-mail: rdodson@kasi.re.kr [Korea Astronomy and Space Science Institute, Daedeokdae-ro 776, Yuseong-gu, Daejeon 305-348 (Korea, Republic of); and others

    2014-11-01

    Oxygen-rich asymptotic giant branch (AGB) stars can be intense emitters of SiO (v = 1 and 2, J = 1 → 0) and H{sub 2}O maser lines at 43 and 22 GHz, respectively. Very long baseline interferometry (VLBI) observations of the maser emission provide a unique tool to probe the innermost layers of the circumstellar envelopes in AGB stars. Nevertheless, the difficulties in achieving astrometrically aligned H{sub 2}O and v = 1 and v = 2 SiO maser maps have traditionally limited the physical constraints that can be placed on the SiO maser pumping mechanism. We present phase-referenced simultaneous spectral-line VLBI images for the SiO v = 1 and v = 2, J = 1 → 0, and H{sub 2}O maser emission around the AGB star R LMi, obtained from the Korean VLBI Network (KVN). The simultaneous multi-channel receivers of the KVN offer great possibilities for astrometry in the frequency domain. With this facility, we have produced images with bona fide absolute astrometric registration between high-frequency maser transitions of different species to provide the positions of the H{sub 2}O maser emission and the center of the SiO maser emission, hence reducing the uncertainty in the proper motions for R LMi by an order of magnitude over that from Hipparcos. This is the first successful demonstration of source frequency phase referencing for millimeter VLBI spectral-line observations and also where the ratio between the frequencies is not an integer.

  2. Image Gallery

    Science.gov (United States)

    ... R S T U V W X Y Z Image Gallery Share: The Image Gallery contains high-quality digital photographs available from ... Select a category below to view additional thumbnail images. Images are available for direct download in 2 ...

  3. Selections from 2017: Image Processing with AstroImageJ

    Science.gov (United States)

    Kohler, Susanna

    2017-12-01

    Editors note:In these last two weeks of 2017, well be looking at a few selections that we havent yet discussed on AAS Nova from among the most-downloaded paperspublished in AAS journals this year. The usual posting schedule will resume in January.AstroImageJ: Image Processing and Photometric Extraction for Ultra-Precise Astronomical Light CurvesPublished January2017The AIJ image display. A wide range of astronomy specific image display options and image analysis tools are available from the menus, quick access icons, and interactive histogram. [Collins et al. 2017]Main takeaway:AstroImageJ is a new integrated software package presented in a publication led byKaren Collins(Vanderbilt University,Fisk University, andUniversity of Louisville). Itenables new users even at the level of undergraduate student, high school student, or amateur astronomer to quickly start processing, modeling, and plotting astronomical image data.Why its interesting:Science doesnt just happen the momenta telescope captures a picture of a distantobject. Instead, astronomical images must firstbe carefully processed to clean up thedata, and this data must then be systematically analyzed to learn about the objects within it. AstroImageJ as a GUI-driven, easily installed, public-domain tool is a uniquelyaccessible tool for thisprocessing and analysis, allowing even non-specialist users to explore and visualizeastronomical data.Some features ofAstroImageJ:(as reported by Astrobites)Image calibration:generate master flat, dark, and bias framesImage arithmetic:combineimages viasubtraction, addition, division, multiplication, etc.Stack editing:easily perform operations on a series of imagesImage stabilization and image alignment featuresPrecise coordinate converters:calculate Heliocentric and Barycentric Julian DatesWCS coordinates:determine precisely where atelescope was pointed for an image by PlateSolving using Astronomy.netMacro and plugin support:write your own macrosMulti-aperture photometry

  4. Medical imaging technology

    CERN Document Server

    Haidekker, Mark A

    2013-01-01

    Biomedical imaging is a relatively young discipline that started with Conrad Wilhelm Roentgen’s discovery of the x-ray in 1885. X-ray imaging was rapidly adopted in hospitals around the world. However, it was the advent of computerized data and image processing that made revolutionary new imaging modalities possible. Today, cross-sections and three-dimensional reconstructions of the organs inside the human body is possible with unprecedented speed, detail and quality. This book provides an introduction into the principles of image formation of key medical imaging modalities: X-ray projection imaging, x-ray computed tomography, magnetic resonance imaging, ultrasound imaging, and radionuclide imaging. Recent developments in optical imaging are also covered. For each imaging modality, the introduction into the physical principles and sources of contrast is provided, followed by the methods of image formation, engineering aspects of the imaging devices, and a discussion of strengths and limitations of the modal...

  5. Annotating images by mining image search results

    NARCIS (Netherlands)

    Wang, X.J.; Zhang, L.; Li, X.; Ma, W.Y.

    2008-01-01

    Although it has been studied for years by the computer vision and machine learning communities, image annotation is still far from practical. In this paper, we propose a novel attempt at model-free image annotation, which is a data-driven approach that annotates images by mining their search

  6. Automatic detection of blurred images in UAV image sets

    Science.gov (United States)

    Sieberth, Till; Wackrow, Rene; Chandler, Jim H.

    2016-12-01

    Unmanned aerial vehicles (UAV) have become an interesting and active research topic for photogrammetry. Current research is based on images acquired by an UAV, which have a high ground resolution and good spectral and radiometrical resolution, due to the low flight altitudes combined with a high resolution camera. UAV image flights are also cost effective and have become attractive for many applications including, change detection in small scale areas. One of the main problems preventing full automation of data processing of UAV imagery is the degradation effect of blur caused by camera movement during image acquisition. This can be caused by the normal flight movement of the UAV as well as strong winds, turbulence or sudden operator inputs. This blur disturbs the visual analysis and interpretation of the data, causes errors and can degrade the accuracy in automatic photogrammetric processing algorithms. The detection and removal of these images is currently achieved manually, which is both time consuming and prone to error, particularly for large image-sets. To increase the quality of data processing an automated process is necessary, which must be both reliable and quick. This paper describes the development of an automatic filtering process, which is based upon the quantification of blur in an image. Images with known blur are processed digitally to determine a quantifiable measure of image blur. The algorithm is required to process UAV images fast and reliably to relieve the operator from detecting blurred images manually. The newly developed method makes it possible to detect blur caused by linear camera displacement and is based on human detection of blur. Humans detect blurred images best by comparing it to other images in order to establish whether an image is blurred or not. The developed algorithm simulates this procedure by creating an image for comparison using image processing. Creating internally a comparable image makes the method independent of

  7. Image quality (IQ) guided multispectral image compression

    Science.gov (United States)

    Zheng, Yufeng; Chen, Genshe; Wang, Zhonghai; Blasch, Erik

    2016-05-01

    Image compression is necessary for data transportation, which saves both transferring time and storage space. In this paper, we focus on our discussion on lossy compression. There are many standard image formats and corresponding compression algorithms, for examples, JPEG (DCT -- discrete cosine transform), JPEG 2000 (DWT -- discrete wavelet transform), BPG (better portable graphics) and TIFF (LZW -- Lempel-Ziv-Welch). The image quality (IQ) of decompressed image will be measured by numerical metrics such as root mean square error (RMSE), peak signal-to-noise ratio (PSNR), and structural Similarity (SSIM) Index. Given an image and a specified IQ, we will investigate how to select a compression method and its parameters to achieve an expected compression. Our scenario consists of 3 steps. The first step is to compress a set of interested images by varying parameters and compute their IQs for each compression method. The second step is to create several regression models per compression method after analyzing the IQ-measurement versus compression-parameter from a number of compressed images. The third step is to compress the given image with the specified IQ using the selected compression method (JPEG, JPEG2000, BPG, or TIFF) according to the regressed models. The IQ may be specified by a compression ratio (e.g., 100), then we will select the compression method of the highest IQ (SSIM, or PSNR). Or the IQ may be specified by a IQ metric (e.g., SSIM = 0.8, or PSNR = 50), then we will select the compression method of the highest compression ratio. Our experiments tested on thermal (long-wave infrared) images (in gray scales) showed very promising results.

  8. Vaccine Images on Twitter: Analysis of What Images are Shared

    Science.gov (United States)

    Dredze, Mark

    2018-01-01

    Background Visual imagery plays a key role in health communication; however, there is little understanding of what aspects of vaccine-related images make them effective communication aids. Twitter, a popular venue for discussions related to vaccination, provides numerous images that are shared with tweets. Objective The objectives of this study were to understand how images are used in vaccine-related tweets and provide guidance with respect to the characteristics of vaccine-related images that correlate with the higher likelihood of being retweeted. Methods We collected more than one million vaccine image messages from Twitter and characterized various properties of these images using automated image analytics. We fit a logistic regression model to predict whether or not a vaccine image tweet was retweeted, thus identifying characteristics that correlate with a higher likelihood of being shared. For comparison, we built similar models for the sharing of vaccine news on Facebook and for general image tweets. Results Most vaccine-related images are duplicates (125,916/237,478; 53.02%) or taken from other sources, not necessarily created by the author of the tweet. Almost half of the images contain embedded text, and many include images of people and syringes. The visual content is highly correlated with a tweet’s textual topics. Vaccine image tweets are twice as likely to be shared as nonimage tweets. The sentiment of an image and the objects shown in the image were the predictive factors in determining whether an image was retweeted. Conclusions We are the first to study vaccine images on Twitter. Our findings suggest future directions for the study and use of vaccine imagery and may inform communication strategies around vaccination. Furthermore, our study demonstrates an effective study methodology for image analysis. PMID:29615386

  9. Vaccine Images on Twitter: Analysis of What Images are Shared.

    Science.gov (United States)

    Chen, Tao; Dredze, Mark

    2018-04-03

    Visual imagery plays a key role in health communication; however, there is little understanding of what aspects of vaccine-related images make them effective communication aids. Twitter, a popular venue for discussions related to vaccination, provides numerous images that are shared with tweets. The objectives of this study were to understand how images are used in vaccine-related tweets and provide guidance with respect to the characteristics of vaccine-related images that correlate with the higher likelihood of being retweeted. We collected more than one million vaccine image messages from Twitter and characterized various properties of these images using automated image analytics. We fit a logistic regression model to predict whether or not a vaccine image tweet was retweeted, thus identifying characteristics that correlate with a higher likelihood of being shared. For comparison, we built similar models for the sharing of vaccine news on Facebook and for general image tweets. Most vaccine-related images are duplicates (125,916/237,478; 53.02%) or taken from other sources, not necessarily created by the author of the tweet. Almost half of the images contain embedded text, and many include images of people and syringes. The visual content is highly correlated with a tweet's textual topics. Vaccine image tweets are twice as likely to be shared as nonimage tweets. The sentiment of an image and the objects shown in the image were the predictive factors in determining whether an image was retweeted. We are the first to study vaccine images on Twitter. Our findings suggest future directions for the study and use of vaccine imagery and may inform communication strategies around vaccination. Furthermore, our study demonstrates an effective study methodology for image analysis. ©Tao Chen, Mark Dredze. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 03.04.2018.

  10. 1992 Data Bank for Red Oak Lumber

    Science.gov (United States)

    Charles J. Gatchell; Janice K. Wiedenbeck; Elizabeth S. Walker; Elizabeth S. Walker

    1992-01-01

    The 1992 Data Bank for Red Oak Lumber is a collection of fully described FAS, Selects, No. 1 Common, and No. 2A Common boards (a total of 1,578 at present). The data bank has two unique features to aid in sample selection. The first feature is the double grading of FAS, No. 1 Common, and No. 2A Common boards to reflect the surface area in grading cuttings when grading...

  11. Designing Networks that are Capable of Self-Healing and Adapting

    Science.gov (United States)

    2017-04-01

    battlefield, and utility infrastructure in cities . Networks that are easy to repair after many breaks. The origi- nal networks (left), the networks after...8725 John J. Kingman Road, MS 6201 Fort Belvoir, VA 22060-6201 T E C H N IC A L R E P O R T DTRA-TR-15-78 Designing Networks that are...from statistical mechanics, combinatorics, boolean networks , and numerical simulations, and inspired by design principles from biological networks , we

  12. Image fusion in x-ray differential phase-contrast imaging

    Science.gov (United States)

    Haas, W.; Polyanskaya, M.; Bayer, F.; Gödel, K.; Hofmann, H.; Rieger, J.; Ritter, A.; Weber, T.; Wucherer, L.; Durst, J.; Michel, T.; Anton, G.; Hornegger, J.

    2012-02-01

    Phase-contrast imaging is a novel modality in the field of medical X-ray imaging. The pioneer method is the grating-based interferometry which has no special requirements to the X-ray source and object size. Furthermore, it provides three different types of information of an investigated object simultaneously - absorption, differential phase-contrast and dark-field images. Differential phase-contrast and dark-field images represent a completely new information which has not yet been investigated and studied in context of medical imaging. In order to introduce phase-contrast imaging as a new modality into medical environment the resulting information about the object has to be correctly interpreted. The three output images reflect different properties of the same object the main challenge is to combine and visualize these data in such a way that it diminish the information explosion and reduce the complexity of its interpretation. This paper presents an intuitive image fusion approach which allows to operate with grating-based phase-contrast images. It combines information of the three different images and provides a single image. The approach is implemented in a fusion framework which is aimed to support physicians in study and analysis. The framework provides the user with an intuitive graphical user interface allowing to control the fusion process. The example given in this work shows the functionality of the proposed method and the great potential of phase-contrast imaging in medical practice.

  13. Readout-Segmented Echo-Planar Imaging in Diffusion-Weighted MR Imaging in Breast Cancer: Comparison with Single-Shot Echo-Planar Imaging in Image Quality

    International Nuclear Information System (INIS)

    Kim, Yun Ju; Kim, Sung Hun; Kang, Bong Joo; Park, Chang Suk; Kim, Hyeon Sook; Son, Yo Han; Porter, David Andrew; Song, Byung Joo

    2014-01-01

    The purpose of this study was to compare the image quality of standard single-shot echo-planar imaging (ss-EPI) and that of readout-segmented EPI (rs-EPI) in patients with breast cancer. Seventy-one patients with 74 breast cancers underwent both ss-EPI and rs-EPI. For qualitative comparison of image quality, three readers independently assessed the two sets of diffusion-weighted (DW) images. To evaluate geometric distortion, a comparison was made between lesion lengths derived from contrast enhanced MR (CE-MR) images and those obtained from the corresponding DW images. For assessment of image parameters, signal-to-noise ratio (SNR), lesion contrast, and contrast-to-noise ratio (CNR) were calculated. The rs-EPI was superior to ss-EPI in most criteria regarding the qualitative image quality. Anatomical structure distinction, delineation of the lesion, ghosting artifact, and overall image quality were significantly better in rs-EPI. Regarding the geometric distortion, lesion length on ss-EPI was significantly different from that of CE-MR, whereas there were no significant differences between CE-MR and rs-EPI. The rs-EPI was superior to ss-EPI in SNR and CNR. Readout-segmented EPI is superior to ss-EPI in the aspect of image quality in DW MR imaging of the breast

  14. Video retrieval by still-image analysis with ImageMiner

    Science.gov (United States)

    Kreyss, Jutta; Roeper, M.; Alshuth, Peter; Hermes, Thorsten; Herzog, Otthein

    1997-01-01

    The large amount of available multimedia information (e.g. videos, audio, images) requires efficient and effective annotation and retrieval methods. As videos start playing a more important role in the frame of multimedia, we want to make these available for content-based retrieval. The ImageMiner-System, which was developed at the University of Bremen in the AI group, is designed for content-based retrieval of single images by a new combination of techniques and methods from computer vision and artificial intelligence. In our approach to make videos available for retrieval in a large database of videos and images there are two necessary steps: First, the detection and extraction of shots from a video, which is done by a histogram based method and second, the construction of the separate frames in a shot to one still single images. This is performed by a mosaicing-technique. The resulting mosaiced image gives a one image visualization of the shot and can be analyzed by the ImageMiner-System. ImageMiner has been tested on several domains, (e.g. landscape images, technical drawings), which cover a wide range of applications.

  15. Stable image acquisition for mobile image processing applications

    Science.gov (United States)

    Henning, Kai-Fabian; Fritze, Alexander; Gillich, Eugen; Mönks, Uwe; Lohweg, Volker

    2015-02-01

    Today, mobile devices (smartphones, tablets, etc.) are widespread and of high importance for their users. Their performance as well as versatility increases over time. This leads to the opportunity to use such devices for more specific tasks like image processing in an industrial context. For the analysis of images requirements like image quality (blur, illumination, etc.) as well as a defined relative position of the object to be inspected are crucial. Since mobile devices are handheld and used in constantly changing environments the challenge is to fulfill these requirements. We present an approach to overcome the obstacles and stabilize the image capturing process such that image analysis becomes significantly improved on mobile devices. Therefore, image processing methods are combined with sensor fusion concepts. The approach consists of three main parts. First, pose estimation methods are used to guide a user moving the device to a defined position. Second, the sensors data and the pose information are combined for relative motion estimation. Finally, the image capturing process is automated. It is triggered depending on the alignment of the device and the object as well as the image quality that can be achieved under consideration of motion and environmental effects.

  16. Spectrally Consistent Satellite Image Fusion with Improved Image Priors

    DEFF Research Database (Denmark)

    Nielsen, Allan Aasbjerg; Aanæs, Henrik; Jensen, Thomas B.S.

    2006-01-01

    Here an improvement to our previous framework for satellite image fusion is presented. A framework purely based on the sensor physics and on prior assumptions on the fused image. The contributions of this paper are two fold. Firstly, a method for ensuring 100% spectrally consistency is proposed......, even when more sophisticated image priors are applied. Secondly, a better image prior is introduced, via data-dependent image smoothing....

  17. Image quality dependence on image processing software in ...

    African Journals Online (AJOL)

    Image quality dependence on image processing software in computed radiography. ... Agfa CR readers use MUSICA software, and an upgrade with significantly different image ... Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  18. Parallel MR imaging.

    Science.gov (United States)

    Deshmane, Anagha; Gulani, Vikas; Griswold, Mark A; Seiberlich, Nicole

    2012-07-01

    Parallel imaging is a robust method for accelerating the acquisition of magnetic resonance imaging (MRI) data, and has made possible many new applications of MR imaging. Parallel imaging works by acquiring a reduced amount of k-space data with an array of receiver coils. These undersampled data can be acquired more quickly, but the undersampling leads to aliased images. One of several parallel imaging algorithms can then be used to reconstruct artifact-free images from either the aliased images (SENSE-type reconstruction) or from the undersampled data (GRAPPA-type reconstruction). The advantages of parallel imaging in a clinical setting include faster image acquisition, which can be used, for instance, to shorten breath-hold times resulting in fewer motion-corrupted examinations. In this article the basic concepts behind parallel imaging are introduced. The relationship between undersampling and aliasing is discussed and two commonly used parallel imaging methods, SENSE and GRAPPA, are explained in detail. Examples of artifacts arising from parallel imaging are shown and ways to detect and mitigate these artifacts are described. Finally, several current applications of parallel imaging are presented and recent advancements and promising research in parallel imaging are briefly reviewed. Copyright © 2012 Wiley Periodicals, Inc.

  19. Medical Imaging System

    Science.gov (United States)

    1991-01-01

    The MD Image System, a true-color image processing system that serves as a diagnostic aid and tool for storage and distribution of images, was developed by Medical Image Management Systems, Huntsville, AL, as a "spinoff from a spinoff." The original spinoff, Geostar 8800, developed by Crystal Image Technologies, Huntsville, incorporates advanced UNIX versions of ELAS (developed by NASA's Earth Resources Laboratory for analysis of Landsat images) for general purpose image processing. The MD Image System is an application of this technology to a medical system that aids in the diagnosis of cancer, and can accept, store and analyze images from other sources such as Magnetic Resonance Imaging.

  20. Retinal imaging and image analysis

    NARCIS (Netherlands)

    Abramoff, M.D.; Garvin, Mona K.; Sonka, Milan

    2010-01-01

    Many important eye diseases as well as systemic diseases manifest themselves in the retina. While a number of other anatomical structures contribute to the process of vision, this review focuses on retinal imaging and image analysis. Following a brief overview of the most prevalent causes of

  1. Imaging of melorheostosis : emphasis on MR imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Hyon; Lee, Sang Kwon; Kim, Jong Yeol; Shin, Tae Bum; Kim, Young Whan; Pak, Hyo Yong; Kim, Yong Joo; Kang, Duk Sik [College of Medicine, Kyungpook National University, Taegu (Korea, Republic of); Lee, Yeong Hwan [College of Medicine, Catholic University of Taegu-Hyosung, Taegu (Korea, Republic of); Byun, Kyung Hwan [Kumi CHA General Hospital, College of Medicine, Pochon CHA University, Kumi (Korea, Republic of)

    2000-02-01

    To evaluate the usefulness of various radiographic imaging modalities in the diagnosis and characterization of melorheostosis. We retrospectively evaluated the plain film (n=3D8), computed tomographic (CT) imaging (n=3D5) and magnetic resonance (MR) imaging (n=3D5) findings of eight patients with melorheostosis diagnosed by bone biopsy (n=3D4) and characteristic radiographic findings (n=3D8). MR images were obtained with a 1.5-T scanner focused on the region of maximal radiographic abnormality. Pulse sequences include T1-weighted SE. T2-weighted fast SE (n=3D5) and postcontrast imaging (n=3D4). In order to define subtle enhancement of the lesions, subtraction MR images were obtained in one case. Imaging findings were analyzed with particular emphasis on the distribution lesions along the sclerotome, differential radiographic findings between diaphyseal and metaepiphyseal lesions of the long bones, as seen on plain radiographs, and the density and signal characteristics of hyperostotic lesions, as seen on CT and MR images. Characteristic distribution along the sclerotome was identified in five of eight cases mainly along C6 and 7 (n=3D2) and L3, 4 and 5 (n=3D3) sclerotomes. In diaphyseal melorherostosis (8/8), a characteristic finding, i.e., a wax flowing down from the candle, was identified on plain radiographs. In all three patients with metaepiphyseal melorheostosis (3/8), multiple round or oval hyperostotic lesions were seen in the epipysis and metaphysis of the long bones. On CT, the marrow cavity was partly obliterated by hyperostotic lesions in all five patients with endosteal hyperostosis. Among these, central ground glass opacity with a sclerotic rim was seen in three patients. Periosteal hyperostosis was seen in two of five cases, being visualized as irregular excrescence in the periosteal region and surrounding soft tissue. Individual hyperostosis was visualized as hypointense on T1-weighted images and as a hyperintense center with a surrounding

  2. COMPARISON OF IMAGE ENHANCEMENT METHODS FOR CHROMOSOME KARYOTYPE IMAGE ENHANCEMENT

    Directory of Open Access Journals (Sweden)

    Dewa Made Sri Arsa

    2017-02-01

    Full Text Available The chromosome is a set of DNA structure that carry information about our life. The information can be obtained through Karyotyping. The process requires a clear image so the chromosome can be evaluate well. Preprocessing have to be done on chromosome images that is image enhancement. The process starts with image background removing. The image will be cleaned background color. The next step is image enhancement. This paper compares several methods for image enhancement. We evaluate some method in image enhancement like Histogram Equalization (HE, Contrast-limiting Adaptive Histogram Equalization (CLAHE, Histogram Equalization with 3D Block Matching (HE+BM3D, and basic image enhancement, unsharp masking. We examine and discuss the best method for enhancing chromosome image. Therefore, to evaluate the methods, the original image was manipulated by the addition of some noise and blur. Peak Signal-to-noise Ratio (PSNR and Structural Similarity Index (SSIM are used to examine method performance. The output of enhancement method will be compared with result of Professional software for karyotyping analysis named Ikaros MetasystemT M . Based on experimental results, HE+BM3D method gets a stable result on both scenario noised and blur image.

  3. Quantitative assessment of dynamic PET imaging data in cancer imaging.

    Science.gov (United States)

    Muzi, Mark; O'Sullivan, Finbarr; Mankoff, David A; Doot, Robert K; Pierce, Larry A; Kurland, Brenda F; Linden, Hannah M; Kinahan, Paul E

    2012-11-01

    Clinical imaging in positron emission tomography (PET) is often performed using single-time-point estimates of tracer uptake or static imaging that provides a spatial map of regional tracer concentration. However, dynamic tracer imaging can provide considerably more information about in vivo biology by delineating both the temporal and spatial pattern of tracer uptake. In addition, several potential sources of error that occur in static imaging can be mitigated. This review focuses on the application of dynamic PET imaging to measuring regional cancer biologic features and especially in using dynamic PET imaging for quantitative therapeutic response monitoring for cancer clinical trials. Dynamic PET imaging output parameters, particularly transport (flow) and overall metabolic rate, have provided imaging end points for clinical trials at single-center institutions for years. However, dynamic imaging poses many challenges for multicenter clinical trial implementations from cross-center calibration to the inadequacy of a common informatics infrastructure. Underlying principles and methodology of PET dynamic imaging are first reviewed, followed by an examination of current approaches to dynamic PET image analysis with a specific case example of dynamic fluorothymidine imaging to illustrate the approach. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. Imaging angiogenesis.

    Science.gov (United States)

    Charnley, Natalie; Donaldson, Stephanie; Price, Pat

    2009-01-01

    There is a need for direct imaging of effects on tumor vasculature in assessment of response to antiangiogenic drugs and vascular disrupting agents. Imaging tumor vasculature depends on differences in permeability of vasculature of tumor and normal tissue, which cause changes in penetration of contrast agents. Angiogenesis imaging may be defined in terms of measurement of tumor perfusion and direct imaging of the molecules involved in angiogenesis. In addition, assessment of tumor hypoxia will give an indication of tumor vasculature. The range of imaging techniques available for these processes includes positron emission tomography (PET), dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), perfusion computed tomography (CT), and ultrasound (US).

  5. X-ray volumetric imaging in image-guided radiotherapy: The new standard in on-treatment imaging

    International Nuclear Information System (INIS)

    McBain, Catherine A.; Henry, Ann M.; Sykes, Jonathan; Amer, Ali; Marchant, Tom; Moore, Christopher M.; Davies, Julie; Stratford, Julia; McCarthy, Claire; Porritt, Bridget; Williams, Peter; Khoo, Vincent S.; Price, Pat

    2006-01-01

    Purpose: X-ray volumetric imaging (XVI) for the first time allows for the on-treatment acquisition of three-dimensional (3D) kV cone beam computed tomography (CT) images. Clinical imaging using the Synergy System (Elekta, Crawley, UK) commenced in July 2003. This study evaluated image quality and dose delivered and assessed clinical utility for treatment verification at a range of anatomic sites. Methods and Materials: Single XVIs were acquired from 30 patients undergoing radiotherapy for tumors at 10 different anatomic sites. Patients were imaged in their setup position. Radiation doses received were measured using TLDs on the skin surface. The utility of XVI in verifying target volume coverage was qualitatively assessed by experienced clinicians. Results: X-ray volumetric imaging acquisition was completed in the treatment position at all anatomic sites. At sites where a full gantry rotation was not possible, XVIs were reconstructed from projection images acquired from partial rotations. Soft-tissue definition of organ boundaries allowed direct assessment of 3D target volume coverage at all sites. Individual image quality depended on both imaging parameters and patient characteristics. Radiation dose ranged from 0.003 Gy in the head to 0.03 Gy in the pelvis. Conclusions: On-treatment XVI provided 3D verification images with soft-tissue definition at all anatomic sites at acceptably low radiation doses. This technology sets a new standard in treatment verification and will facilitate novel adaptive radiotherapy techniques

  6. Evaluation of multimodality imaging using image fusion with ultrasound tissue elasticity imaging in an experimental animal model.

    Science.gov (United States)

    Paprottka, P M; Zengel, P; Cyran, C C; Ingrisch, M; Nikolaou, K; Reiser, M F; Clevert, D A

    2014-01-01

    To evaluate the ultrasound tissue elasticity imaging by comparison to multimodality imaging using image fusion with Magnetic Resonance Imaging (MRI) and conventional grey scale imaging with additional elasticity-ultrasound in an experimental small-animal-squamous-cell carcinoma-model for the assessment of tissue morphology. Human hypopharynx carcinoma cells were subcutaneously injected into the left flank of 12 female athymic nude rats. After 10 days (SD ± 2) of subcutaneous tumor growth, sonographic grey scale including elasticity imaging and MRI measurements were performed using a high-end ultrasound system and a 3T MR. For image fusion the contrast-enhanced MRI DICOM data set was uploaded in the ultrasonic device which has a magnetic field generator, a linear array transducer (6-15 MHz) and a dedicated software package (GE Logic E9), that can detect transducers by means of a positioning system. Conventional grey scale and elasticity imaging were integrated in the image fusion examination. After successful registration and image fusion the registered MR-images were simultaneously shown with the respective ultrasound sectional plane. Data evaluation was performed using the digitally stored video sequence data sets by two experienced radiologist using a modified Tsukuba Elasticity score. The colors "red and green" are assigned for an area of soft tissue, "blue" indicates hard tissue. In all cases a successful image fusion and plan registration with MRI and ultrasound imaging including grey scale and elasticity imaging was possible. The mean tumor volume based on caliper measurements in 3 dimensions was ~323 mm3. 4/12 rats were evaluated with Score I, 5/12 rates were evaluated with Score II, 3/12 rates were evaluated with Score III. There was a close correlation in the fused MRI with existing small necrosis in the tumor. None of the scored II or III lesions was visible by conventional grey scale. The comparison of ultrasound tissue elasticity imaging enables a

  7. Symposia

    Indian Academy of Sciences (India)

    Administrator

    2017-11-04

    Nov 4, 2017 ... Chairperson: N Viswanadham, Indian Institute of Science, Bengaluru. 1530 Navakanta Bhat,Indian Institute of Science, Bengaluru. PathShodh: A journey from science to product. 1600 V Padmanabhan, Microsoft Research India, Bengaluru. Low-cost IoT to address societal challenges. 1630 A Bharadwaj ...

  8. "Passie, Hartstocht": Painting and Evoking Emotions in Rembrandt’s Studio

    NARCIS (Netherlands)

    Weststeijn, T.; Fritsche, C.; Leonhard, K.; Weber, G.J.M.

    2013-01-01

    Focusing on Rembrandt’s studio, this chapter explores the theory and practice in the depiction of the passions. It argues that the central importance alotted to portraying and evoking emotions in rhetorical theory inspired painterly experiments in the 1630s and theoretical ideals that were first

  9. The effect of brassinosteroids on the morphology, development and yield of field-grown maize

    Czech Academy of Sciences Publication Activity Database

    Holá, D.; Rothová, O.; Kočová, M.; Kohout, Ladislav; Kvasnica, Miroslav

    2010-01-01

    Roč. 61, č. 1 (2010), s. 29-43 ISSN 0167-6903 R&D Projects: GA AV ČR KJB601110611 Institutional research plan: CEZ:AV0Z40550506 Keywords : flowering * genotypes * growth * Zea mays L Subject RIV: GC - Agronomy Impact factor: 1.630, year: 2010

  10. 76 FR 54753 - Whitestone Power and Communications; Notice of Intent To File License Application, Filing of...

    Science.gov (United States)

    2011-09-02

    ... of Project: Microturbine Hydrokinetic River-In-Stream Energy Conversion Power Project (also known as... Contact: Steven M. Selvaggio, Whitestone Power and Communications, P.O. Box 1630, Delta Junction, Alaska... Hydrokinetic River-In-Stream Energy Conversion Power Project) and number (P-13305-002), and bear the heading...

  11. 75 FR 43148 - Gulf of Mexico Fishery Management Council; Public Meeting

    Science.gov (United States)

    2010-07-23

    ...; telephone: (813) 348-1630 x235. SUPPLEMENTARY INFORMATION: The Vessel Monitoring System Advisory Panel will meet to discuss operation, design, agency usage of vessel monitoring systems (VMS), and resulting data... Advisory Panel will also consider current and future VMS design to determine if existing systems are...

  12. Modern Aspects of Halophilism: The Edmond de Rothschild School in Molecular Biophysics (12th) Held in Israel on March 26-April 5, 1989. Program and Abstracts

    Science.gov (United States)

    1989-04-01

    pairs 16:30 CHRISTINE EBEL Study of the stability and activity of the elongation factor Tu from Halobacterlum marismortul at different salt conditions...RELEVANT LITERATURE Alfano RR, Yu W, Govindjee R, Becher B, Ebrey TG (1976). Picosecond kinetics of the fluorescence from the chromophore of the

  13. BLOOD DONORS CAMPAIGN

    CERN Document Server

    2002-01-01

    Wednesday 13 November 2002 in restaurant nr 2, from 8.30 to 16.30 hrs will be held a blood donors campaign, organized by the Etablissement de Transfusion de Haute-Savoie If you already have a card giving your blood group, please bring this with you.

  14. 28 CFR 37.12 - Standards.

    Science.gov (United States)

    2010-07-01

    ... Administration DEPARTMENT OF JUSTICE PROCEDURES FOR COORDINATING THE INVESTIGATION OF COMPLAINTS OR CHARGES OF... OF THE REHABILITATION ACT OF 1973 § 37.12 Standards. In any investigation, compliance review, hearing... 29 CFR part 1630, and case law arising under such regulations, in determining whether a recipient of...

  15. The Role of Career Competencies in the Job Demands-Resources Model

    NARCIS (Netherlands)

    Akkermans, J.; Schaufeli, W.B.; Brenninkmeijer, V.; Blonk, R.W.B.

    2013-01-01

    This study investigated the role of career competencies as a mediator in the Job Demands - Resources model. Structural equation modeling with data from 305 young employed persons aged 16-30 years showed that career competencies are positively related to job resources and work engagement, but not to

  16. 77 FR 42698 - Gulf of Mexico Fishery Management Council; Public Meeting

    Science.gov (United States)

    2012-07-20

    ... essential fish habitat. The AP will also reconsider its recommendations from an October 2011 meeting on.... SUMMARY: The Gulf of Mexico Fishery Management Council will convene a meeting of the Reef Fish Advisory... Management Council; telephone: (813) 348-1630. SUPPLEMENTARY INFORMATION: The Reef Fish Advisory Panel (AP...

  17. Matching rendered and real world images by digital image processing

    Science.gov (United States)

    Mitjà, Carles; Bover, Toni; Bigas, Miquel; Escofet, Jaume

    2010-05-01

    Recent advances in computer-generated images (CGI) have been used in commercial and industrial photography providing a broad scope in product advertising. Mixing real world images with those rendered from virtual space software shows a more or less visible mismatching between corresponding image quality performance. Rendered images are produced by software which quality performance is only limited by the resolution output. Real world images are taken with cameras with some amount of image degradation factors as lens residual aberrations, diffraction, sensor low pass anti aliasing filters, color pattern demosaicing, etc. The effect of all those image quality degradation factors can be characterized by the system Point Spread Function (PSF). Because the image is the convolution of the object by the system PSF, its characterization shows the amount of image degradation added to any taken picture. This work explores the use of image processing to degrade the rendered images following the parameters indicated by the real system PSF, attempting to match both virtual and real world image qualities. The system MTF is determined by the slanted edge method both in laboratory conditions and in the real picture environment in order to compare the influence of the working conditions on the device performance; an approximation to the system PSF is derived from the two measurements. The rendered images are filtered through a Gaussian filter obtained from the taking system PSF. Results with and without filtering are shown and compared measuring the contrast achieved in different final image regions.

  18. Quantum Image Encryption Algorithm Based on Image Correlation Decomposition

    Science.gov (United States)

    Hua, Tianxiang; Chen, Jiamin; Pei, Dongju; Zhang, Wenquan; Zhou, Nanrun

    2015-02-01

    A novel quantum gray-level image encryption and decryption algorithm based on image correlation decomposition is proposed. The correlation among image pixels is established by utilizing the superposition and measurement principle of quantum states. And a whole quantum image is divided into a series of sub-images. These sub-images are stored into a complete binary tree array constructed previously and then randomly performed by one of the operations of quantum random-phase gate, quantum revolving gate and Hadamard transform. The encrypted image can be obtained by superimposing the resulting sub-images with the superposition principle of quantum states. For the encryption algorithm, the keys are the parameters of random phase gate, rotation angle, binary sequence and orthonormal basis states. The security and the computational complexity of the proposed algorithm are analyzed. The proposed encryption algorithm can resist brute force attack due to its very large key space and has lower computational complexity than its classical counterparts.

  19. Chloral hydrate in pediatric magnetic resonance imaging: evaluation of a 10-year sedation experience administered by radiologists

    International Nuclear Information System (INIS)

    Delgado, Jorge; Toro, Rodrigo; Rascovsky, Simon; Arango, Andres; Angel, Gabriel J.; Calvo, Victor; Delgado, Jorge A.

    2015-01-01

    Chloral hydrate is a sedative that has been used for magnetic resonance imaging (MRI). To evaluate the use, effectiveness and safety of chloral hydrate administered by radiologists for the sedation of children who require MRI procedures. We retrospectively reviewed the clinical charts for all patients ages 0 - 10 years old who underwent sedation with chloral hydrate for MRI from January 2000 to December 2010. Demographic factors, dose information, indication for MRI, therapeutic failures and adverse reactions to the drug were reviewed. One thousand, seven hundred and three children (946 males, 757 females) with a median age of 2.5 years (range: 4 days - 9.91 years) received chloral hydrate. Moderate to deep sedation was achieved in 1,618/1,703 (95%) of the patients, 35/1,703 (2.1%) of the patients failed to achieve moderate to deep sedation, and 47/1,703 (2.8%) of the patients woke up during MRI examination. Adverse reactions were present in 31/1,703 (1.8%) of the patients. Three severe adverse reactions occurred (0.18%). A single dose of chloral hydrate (40-60 mg/kg) was administered to 1,477/1,703 patients (86.7%). An additional dose of chloral hydrate (10-20 mg/kg), given 15 min after the first dose or when the patient woke up during the MRI examination, was required in 226/1,703 patients (13.3%). The likelihood of requiring an additional dose in children older than 2 years was 2.2 times the likelihood compared to children younger than 2 years (OR = 2.2 [95%CI: 1.6-3.0]). The use of a reduced dose (<50 mg/kg) was not associated with a higher therapeutic failure rate (OR = 1.04 [95%CI 0.57-1.89]). Chloral hydrate is an appropriate sedation option for pediatric patients in MRI services when strict patient selection criteria are met. The use of a reduced dose does not affect the effectiveness of sedation. The lack of data regarding the presence of transient oxygen desaturation, the time to induce sedation and the exact duration of sedation are limitations of this

  20. Chloral hydrate in pediatric magnetic resonance imaging: evaluation of a 10-year sedation experience administered by radiologists

    Energy Technology Data Exchange (ETDEWEB)

    Delgado, Jorge; Toro, Rodrigo; Rascovsky, Simon; Arango, Andres; Angel, Gabriel J.; Calvo, Victor; Delgado, Jorge A. [Fundacion Instituto de Alta Tecnologia Medica, Department of Radiology, Medellin (Colombia)

    2014-08-21

    Chloral hydrate is a sedative that has been used for magnetic resonance imaging (MRI). To evaluate the use, effectiveness and safety of chloral hydrate administered by radiologists for the sedation of children who require MRI procedures. We retrospectively reviewed the clinical charts for all patients ages 0 - 10 years old who underwent sedation with chloral hydrate for MRI from January 2000 to December 2010. Demographic factors, dose information, indication for MRI, therapeutic failures and adverse reactions to the drug were reviewed. One thousand, seven hundred and three children (946 males, 757 females) with a median age of 2.5 years (range: 4 days - 9.91 years) received chloral hydrate. Moderate to deep sedation was achieved in 1,618/1,703 (95%) of the patients, 35/1,703 (2.1%) of the patients failed to achieve moderate to deep sedation, and 47/1,703 (2.8%) of the patients woke up during MRI examination. Adverse reactions were present in 31/1,703 (1.8%) of the patients. Three severe adverse reactions occurred (0.18%). A single dose of chloral hydrate (40-60 mg/kg) was administered to 1,477/1,703 patients (86.7%). An additional dose of chloral hydrate (10-20 mg/kg), given 15 min after the first dose or when the patient woke up during the MRI examination, was required in 226/1,703 patients (13.3%). The likelihood of requiring an additional dose in children older than 2 years was 2.2 times the likelihood compared to children younger than 2 years (OR = 2.2 [95%CI: 1.6-3.0]). The use of a reduced dose (<50 mg/kg) was not associated with a higher therapeutic failure rate (OR = 1.04 [95%CI 0.57-1.89]). Chloral hydrate is an appropriate sedation option for pediatric patients in MRI services when strict patient selection criteria are met. The use of a reduced dose does not affect the effectiveness of sedation. The lack of data regarding the presence of transient oxygen desaturation, the time to induce sedation and the exact duration of sedation are limitations of this

  1. Corner-point criterion for assessing nonlinear image processing imagers

    Science.gov (United States)

    Landeau, Stéphane; Pigois, Laurent; Foing, Jean-Paul; Deshors, Gilles; Swiathy, Greggory

    2017-10-01

    Range performance modeling of optronics imagers attempts to characterize the ability to resolve details in the image. Today, digital image processing is systematically used in conjunction with the optoelectronic system to correct its defects or to exploit tiny detection signals to increase performance. In order to characterize these processing having adaptive and non-linear properties, it becomes necessary to stimulate the imagers with test patterns whose properties are similar to the actual scene image ones, in terms of dynamic range, contours, texture and singular points. This paper presents an approach based on a Corner-Point (CP) resolution criterion, derived from the Probability of Correct Resolution (PCR) of binary fractal patterns. The fundamental principle lies in the respectful perception of the CP direction of one pixel minority value among the majority value of a 2×2 pixels block. The evaluation procedure considers the actual image as its multi-resolution CP transformation, taking the role of Ground Truth (GT). After a spatial registration between the degraded image and the original one, the degradation is statistically measured by comparing the GT with the degraded image CP transformation, in terms of localized PCR at the region of interest. The paper defines this CP criterion and presents the developed evaluation techniques, such as the measurement of the number of CP resolved on the target, the transformation CP and its inverse transform that make it possible to reconstruct an image of the perceived CPs. Then, this criterion is compared with the standard Johnson criterion, in the case of a linear blur and noise degradation. The evaluation of an imaging system integrating an image display and a visual perception is considered, by proposing an analysis scheme combining two methods: a CP measurement for the highly non-linear part (imaging) with real signature test target and conventional methods for the more linear part (displaying). The application to

  2. Volumetric CT-images improve testing of radiological image interpretation skills

    Energy Technology Data Exchange (ETDEWEB)

    Ravesloot, Cécile J., E-mail: C.J.Ravesloot@umcutrecht.nl [Radiology Department at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, Room E01.132 (Netherlands); Schaaf, Marieke F. van der, E-mail: M.F.vanderSchaaf@uu.nl [Department of Pedagogical and Educational Sciences at Utrecht University, Heidelberglaan 1, 3584 CS Utrecht (Netherlands); Schaik, Jan P.J. van, E-mail: J.P.J.vanSchaik@umcutrecht.nl [Radiology Department at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, Room E01.132 (Netherlands); Cate, Olle Th.J. ten, E-mail: T.J.tenCate@umcutrecht.nl [Center for Research and Development of Education at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht (Netherlands); Gijp, Anouk van der, E-mail: A.vanderGijp-2@umcutrecht.nl [Radiology Department at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht, Room E01.132 (Netherlands); Mol, Christian P., E-mail: C.Mol@umcutrecht.nl [Image Sciences Institute at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht (Netherlands); Vincken, Koen L., E-mail: K.Vincken@umcutrecht.nl [Image Sciences Institute at University Medical Center Utrecht, Heidelberglaan 100, 3508 GA Utrecht (Netherlands)

    2015-05-15

    Rationale and objectives: Current radiology practice increasingly involves interpretation of volumetric data sets. In contrast, most radiology tests still contain only 2D images. We introduced a new testing tool that allows for stack viewing of volumetric images in our undergraduate radiology program. We hypothesized that tests with volumetric CT-images enhance test quality, in comparison with traditional completely 2D image-based tests, because they might better reflect required skills for clinical practice. Materials and methods: Two groups of medical students (n = 139; n = 143), trained with 2D and volumetric CT-images, took a digital radiology test in two versions (A and B), each containing both 2D and volumetric CT-image questions. In a questionnaire, they were asked to comment on the representativeness for clinical practice, difficulty and user-friendliness of the test questions and testing program. Students’ test scores and reliabilities, measured with Cronbach's alpha, of 2D and volumetric CT-image tests were compared. Results: Estimated reliabilities (Cronbach's alphas) were higher for volumetric CT-image scores (version A: .51 and version B: .54), than for 2D CT-image scores (version A: .24 and version B: .37). Participants found volumetric CT-image tests more representative of clinical practice, and considered them to be less difficult than volumetric CT-image questions. However, in one version (A), volumetric CT-image scores (M 80.9, SD 14.8) were significantly lower than 2D CT-image scores (M 88.4, SD 10.4) (p < .001). The volumetric CT-image testing program was considered user-friendly. Conclusion: This study shows that volumetric image questions can be successfully integrated in students’ radiology testing. Results suggests that the inclusion of volumetric CT-images might improve the quality of radiology tests by positively impacting perceived representativeness for clinical practice and increasing reliability of the test.

  3. Nuclear imaging in the realm of medical imaging

    International Nuclear Information System (INIS)

    Deconinck, Frank

    2003-01-01

    In medical imaging, information concerning the anatomy or biological processes of a patient is detected and presented on film or screen for interpretation by a reader. The information flow from patient to reader optimally implies: - the emission, transmission or reflection of information carriers, typically photons or sound waves, which have to be correctly modulated by patient information through interactions in the patient; - their detection by adequate imaging equipment preserving essential spectral, spatial and/or temporal information; - the presentation of the information in the most perceivable way; - the observation by an unbiased and trained expert. In reality, only an approximation to this optimal situation is achieved. It is the goal of R and D in the medical imaging field to approach the optimum as much as possible within societal constraints such as patient risk and comfort, economics, etc. First, the basic physical concepts underlying the imaging process will be introduced. Different imaging modalities will then be situated in the realm of medical imaging with some emphasis on nuclear imaging

  4. Image city

    DEFF Research Database (Denmark)

    2003-01-01

    Image city exhibition explores a condition of mediation, through a focus on image and sound narratives with a point of departure on a number of Asian cities.......Image city exhibition explores a condition of mediation, through a focus on image and sound narratives with a point of departure on a number of Asian cities....

  5. Analysis of image plane's Illumination in Image-forming System

    International Nuclear Information System (INIS)

    Duan Lihua; Zeng Yan'an; Zhang Nanyangsheng; Wang Zhiguo; Yin Shiliang

    2011-01-01

    In the detection of optical radiation, the detecting accuracy is affected by optic power distribution of the detector's surface to a large extent. In addition, in the image-forming system, the quality of the image is greatly determined by the uniformity of the image's illumination distribution. However, in the practical optical system, affected by the factors such as field of view, false light and off axis and so on, the distribution of the image's illumination tends to be non uniform, so it is necessary to discuss the image plane's illumination in image-forming systems. In order to analyze the characteristics of the image-forming system at a full range, on the basis of photometry, the formulas to calculate the illumination of the imaging plane have been summarized by the numbers. Moreover, the relationship between the horizontal offset of the light source and the illumination of the image has been discussed in detail. After that, the influence of some key factors such as aperture angle, off-axis distance and horizontal offset on illumination of the image has been brought forward. Through numerical simulation, various theoretical curves of those key factors have been given. The results of the numerical simulation show that it is recommended to aggrandize the diameter of the exit pupil to increase the illumination of the image. The angle of view plays a negative role in the illumination distribution of the image, that is, the uniformity of the illumination distribution can be enhanced by compressing the angle of view. Lastly, it is proved that telecentric optical design is an effective way to advance the uniformity of the illumination distribution.

  6. Fast processing of foreign fiber images by image blocking

    OpenAIRE

    Yutao Wu; Daoliang Li; Zhenbo Li; Wenzhu Yang

    2014-01-01

    In the textile industry, it is always the case that cotton products are constitutive of many types of foreign fibers which affect the overall quality of cotton products. As the foundation of the foreign fiber automated inspection, image process exerts a critical impact on the process of foreign fiber identification. This paper presents a new approach for the fast processing of foreign fiber images. This approach includes five main steps, image block, image pre-decision, image background extra...

  7. Image processing on the image with pixel noise bits removed

    Science.gov (United States)

    Chuang, Keh-Shih; Wu, Christine

    1992-06-01

    Our previous studies used statistical methods to assess the noise level in digital images of various radiological modalities. We separated the pixel data into signal bits and noise bits and demonstrated visually that the removal of the noise bits does not affect the image quality. In this paper we apply image enhancement techniques on noise-bits-removed images and demonstrate that the removal of noise bits has no effect on the image property. The image processing techniques used are gray-level look up table transformation, Sobel edge detector, and 3-D surface display. Preliminary results show no noticeable difference between original image and noise bits removed image using look up table operation and Sobel edge enhancement. There is a slight enhancement of the slicing artifact in the 3-D surface display of the noise bits removed image.

  8. Hybrid Image Fusion for Sharpness Enhancement of Multi-Spectral Lunar Images

    Science.gov (United States)

    Awumah, Anna; Mahanti, Prasun; Robinson, Mark

    2016-10-01

    Image fusion enhances the sharpness of a multi-spectral (MS) image by incorporating spatial details from a higher-resolution panchromatic (Pan) image [1,2]. Known applications of image fusion for planetary images are rare, although image fusion is well-known for its applications to Earth-based remote sensing. In a recent work [3], six different image fusion algorithms were implemented and their performances were verified with images from the Lunar Reconnaissance Orbiter (LRO) Camera. The image fusion procedure obtained a high-resolution multi-spectral (HRMS) product from the LRO Narrow Angle Camera (used as Pan) and LRO Wide Angle Camera (used as MS) images. The results showed that the Intensity-Hue-Saturation (IHS) algorithm results in a high-spatial quality product while the Wavelet-based image fusion algorithm best preserves spectral quality among all the algorithms. In this work we show the results of a hybrid IHS-Wavelet image fusion algorithm when applied to LROC MS images. The hybrid method provides the best HRMS product - both in terms of spatial resolution and preservation of spectral details. Results from hybrid image fusion can enable new science and increase the science return from existing LROC images.[1] Pohl, Cle, and John L. Van Genderen. "Review article multisensor image fusion in remote sensing: concepts, methods and applications." International journal of remote sensing 19.5 (1998): 823-854.[2] Zhang, Yun. "Understanding image fusion." Photogramm. Eng. Remote Sens 70.6 (2004): 657-661.[3] Mahanti, Prasun et al. "Enhancement of spatial resolution of the LROC Wide Angle Camera images." Archives, XXIII ISPRS Congress Archives (2016).

  9. Rapid MR imaging

    International Nuclear Information System (INIS)

    Edelman, R.R.; Buxton, R.B.; Brady, T.J.

    1988-01-01

    Conventional magnetic resonance (MR) imaging methods typically require several minutes to produce an image, but the periods of respiration, cardiac motion and peristalsis are on the order of seconds or less. The need to reduce motion artifact, as well as the need to reduce imaging time for patient comfort and efficiency, have provided a strong impetus for the development of rapid imaging methods. For abdominal imaging, motion artifacts due to respiration can be significantly reduced by collecting the entire image during one breath hold. For other applications, such as following the kinetics of administered contrast agents, rapid imaging is essential to achieve adequate time resolution. A shorter imaging time entails a cost in image signal/noise (S/N), but improvements in recent years in magnet homogeneity, gradient and radiofrequency coil design have led to steady improvements in S/N and consequently in image quality. For many chemical applications the available S/N is greater than needed, and a trade-off of lower S/N for a shorter imaging time is acceptable. In this chapter, the authors consider the underlying principles of rapid imaging as well as clinical applications of these methods. The bulk of this review concentrates on short TR imaging, but methods that provide for a more modest decrease in imaging time as well as or those that dramatically shorten the imaging time to tens of milliseconds are also discussed

  10. Measurement of brain perfusion, blood volume, and blood-brain barrier permeability, using dynamic contrast-enhanced T(1)-weighted MRI at 3 tesla

    DEFF Research Database (Denmark)

    Larsson, Henrik B W; Courivaud, Frédéric; Rostrup, Egill

    2009-01-01

    Assessment of vascular properties is essential to diagnosis and follow-up and basic understanding of pathogenesis in brain tumors. In this study, a procedure is presented that allows concurrent estimation of cerebral perfusion, blood volume, and blood-brain permeability from dynamic T(1)-weighted...... on a pixel-by-pixel basis of cerebral perfusion, cerebral blood volume, and blood-brain barrier permeability.......Assessment of vascular properties is essential to diagnosis and follow-up and basic understanding of pathogenesis in brain tumors. In this study, a procedure is presented that allows concurrent estimation of cerebral perfusion, blood volume, and blood-brain permeability from dynamic T(1)-weighted...... imaging of a bolus of a paramagnetic contrast agent passing through the brain. The methods are applied in patients with brain tumors and in healthy subjects. Perfusion was estimated by model-free deconvolution using Tikhonov's method (gray matter/white matter/tumor: 72 +/- 16/30 +/- 8/56 +/- 45 mL/100 g...

  11. Desulphurization characteristics of bamboo charcoal from sulfur solution

    Directory of Open Access Journals (Sweden)

    Shengbo Ge

    2017-01-01

    Full Text Available Sulfur powder and sulfur dioxide (SO2 often floated in air, produced acid rain and algal blooms, and could cause diseases. Bamboo charcoal could have adsorption and filtration properties. In order to figure out the optimal adsorption condition and the intrinsic change of the bamboo charcoal, five chemicals were adsorbed by bamboo charcoal and were analyzed by FT-IR. Fe2(SO43’s, Na2SO4’s, Na2S2O8’s, S’s, and Na2SO3’s optimal adsorption condition was the concentration of 19 g/1000 g and stir time of 20 min, 21 g/1000 g and stir time of 60 min, 7 g/1000 g and stir time of 120 min, 11 g/1000 g and stir time of 120 min, 21 g/1000 g and stir time of 60 min, respectively. FT-IR spectra showed that for FT-IR spectra of Fe2(SO43, the transmissivity of the peaks at 3435 cm−1 and 2925 cm−1 achieved the maximum for 60 min and the concentration was 19 g/1000 g, the transmissivity of the peaks at 1630 cm−1, 1060 cm−1 and 660 cm−1 achieved the maximum for 60 min and the concentration was 7 g/1000 g. For FT-IR spectra of Na2SO4, the transmissivity of the peaks at 1630 cm−1, 1060 cm−1 and 660 cm−1 achieved the maximum for 20 min and the concentration was 13 g/1000 g. For FT-IR spectra of Na2S2O8, the transmissivity of the peaks at 3435 cm−1, 2925 cm−1, 1630 cm−1 and 1060 cm−1 achieved the maximum for 120 min and the concentration was 19 g/1000 g. For FT-IR spectra of S, the transmissivity of the peaks at 3435 cm−1, 2925 cm−1, 1630 cm−1 and 1060 cm−1 achieved the maximum for 20 min and the concentration was 11 g/1000 g, 17 g/1000 g and 21 g/1000 g. For FT-IR spectra of Na2SO3, the transmissivity of the peaks at 3435 cm−1 achieved the maximum for 120 min and the concentration was 5 g/1000 g, the transmissivity of the peaks at 2925 cm−1, 1630 cm−1 and 1060 cm−1 achieved the maximum for 120 min and the concentration was 11 g/1000 g. In these states, the

  12. Molecular photoacoustic imaging

    Directory of Open Access Journals (Sweden)

    Frogh Jafarian Dehkordi

    2015-04-01

    Full Text Available Background: Hybrid imaging modalities which simultaneously benefit from capabilities of combined modalities provides an opportunity to modify quality of the images which can be obtained by each of the combined imaging systems. One of the imaging modalities, emerged in medical research area as a hybrid of ultrasound imaging and optical imaging, is photoacoustic imaging which apply ultrasound wave generated by tissue, after receiving laser pulse, to produce medical images. Materials and Methods: In this review, using keywords such as photoacoustic, optoacoustic, laser-ultrasound, thermoacoustic at databases such as PubMed and ISI, studies performed in the field of photoacoustic and related findings were evaluated. Results: Photoacoustic imaging, acquiring images with high contrast and desired resolution, provides an opportunity to perform physiologic and anatomic studies. Because this technique does not use ionizing radiation, it is not restricted by the limitation of the ionizing-based imaging systems therefore it can be used noninvasively to make images from cell, vessels, whole body imaging of the animal and distinguish tumor from normal tissue. Conclusion: Photoacoustic imaging is a new method in preclinical researches which can be used in various physiologic and anatomic studies. This method, because of application of non-ionizing radiation, may resolve limitation of radiation based method in diagnostic assessments.

  13. Image perception and image processing

    International Nuclear Information System (INIS)

    Wackenheim, A.

    1987-01-01

    The author develops theoretical and practical models of image perception and image processing, based on phenomenology and structuralism and leading to original perception: fundamental for a positivistic approach of research work for the development of artificial intelligence that will be able in an automated system fo 'reading' X-ray pictures. (orig.) [de

  14. Image perception and image processing

    Energy Technology Data Exchange (ETDEWEB)

    Wackenheim, A.

    1987-01-01

    The author develops theoretical and practical models of image perception and image processing, based on phenomenology and structuralism and leading to original perception: fundamental for a positivistic approach of research work for the development of artificial intelligence that will be able in an automated system fo 'reading' X-ray pictures.

  15. Image-adaptive and robust digital wavelet-domain watermarking for images

    Science.gov (United States)

    Zhao, Yi; Zhang, Liping

    2018-03-01

    We propose a new frequency domain wavelet based watermarking technique. The key idea of our scheme is twofold: multi-tier solution representation of image and odd-even quantization embedding/extracting watermark. Because many complementary watermarks need to be hidden, the watermark image designed is image-adaptive. The meaningful and complementary watermark images was embedded into the original image (host image) by odd-even quantization modifying coefficients, which was selected from the detail wavelet coefficients of the original image, if their magnitudes are larger than their corresponding Just Noticeable Difference thresholds. The tests show good robustness against best-known attacks such as noise addition, image compression, median filtering, clipping as well as geometric transforms. Further research may improve the performance by refining JND thresholds.

  16. Optimal image resolution for digital storage of radiotherapy-planning images

    International Nuclear Information System (INIS)

    Baba, Yuji; Furusawa, Mitsuhiro; Murakami, Ryuji; Baba, Takashi; Yokoyama, Toshimi; Nishimura, Ryuichi; Takahashi, Mutsumasa

    1998-01-01

    Purpose: To evaluate the quality of digitized radiation-planning images at different resolution and to determine the optimal resolution for digital storage. Methods and Materials: Twenty-five planning films were scanned and digitized using a film scanner at a resolution of 72 dots per inch (dpi) with 8-bit depth. The resolution of scanned images was reduced to 48, 36, 24, and 18 dpi using computer software. Image qualities of these five images (72, 48, 36, 24, and 18 dpi) were evaluated and given scores (4 = excellent; 3 = good; 2 = fair; and 1 = poor) by three radiation oncologists. An image data compression algorithm by the Joint Photographic Experts Group (JPEG) (not reversible and some information will be lost) was also evaluated. Results: The scores of digitized images with 72, 48, 36, 24, and 17 dpi resolution were 3.8 ± 0.3, 3.5 ± 0.3, 3.3 ± 0.5, 2.7 ± 0.5, and 1.6 ± 0.3, respectively. The quality of 36-dpi images were definitely worse compared to 72-dpi images, but were good enough as planning films. Digitized planning images with 72- and 36-dpi resolution requires about 800 and 200 KBytes, respectively. The JPEG compression algorithm produces little degradation in 36-dpi images at compression ratios of 5:1. Conclusion: The quality of digitized images with 36-dpi resolution was good enough as radiation-planning images and required 200 KBytes/image

  17. Quantitative imaging features: extension of the oncology medical image database

    Science.gov (United States)

    Patel, M. N.; Looney, P. T.; Young, K. C.; Halling-Brown, M. D.

    2015-03-01

    Radiological imaging is fundamental within the healthcare industry and has become routinely adopted for diagnosis, disease monitoring and treatment planning. With the advent of digital imaging modalities and the rapid growth in both diagnostic and therapeutic imaging, the ability to be able to harness this large influx of data is of paramount importance. The Oncology Medical Image Database (OMI-DB) was created to provide a centralized, fully annotated dataset for research. The database contains both processed and unprocessed images, associated data, and annotations and where applicable expert determined ground truths describing features of interest. Medical imaging provides the ability to detect and localize many changes that are important to determine whether a disease is present or a therapy is effective by depicting alterations in anatomic, physiologic, biochemical or molecular processes. Quantitative imaging features are sensitive, specific, accurate and reproducible imaging measures of these changes. Here, we describe an extension to the OMI-DB whereby a range of imaging features and descriptors are pre-calculated using a high throughput approach. The ability to calculate multiple imaging features and data from the acquired images would be valuable and facilitate further research applications investigating detection, prognosis, and classification. The resultant data store contains more than 10 million quantitative features as well as features derived from CAD predictions. Theses data can be used to build predictive models to aid image classification, treatment response assessment as well as to identify prognostic imaging biomarkers.

  18. Enhancement system of nighttime infrared video image and visible video image

    Science.gov (United States)

    Wang, Yue; Piao, Yan

    2016-11-01

    Visibility of Nighttime video image has a great significance for military and medicine areas, but nighttime video image has so poor quality that we can't recognize the target and background. Thus we enhance the nighttime video image by fuse infrared video image and visible video image. According to the characteristics of infrared and visible images, we proposed improved sift algorithm andαβ weighted algorithm to fuse heterologous nighttime images. We would deduced a transfer matrix from improved sift algorithm. The transfer matrix would rapid register heterologous nighttime images. And theαβ weighted algorithm can be applied in any scene. In the video image fusion system, we used the transfer matrix to register every frame and then used αβ weighted method to fuse every frame, which reached the time requirement soft video. The fused video image not only retains the clear target information of infrared video image, but also retains the detail and color information of visible video image and the fused video image can fluency play.

  19. An enhanced approach for biomedical image restoration using image fusion techniques

    Science.gov (United States)

    Karam, Ghada Sabah; Abbas, Fatma Ismail; Abood, Ziad M.; Kadhim, Kadhim K.; Karam, Nada S.

    2018-05-01

    Biomedical image is generally noisy and little blur due to the physical mechanisms of the acquisition process, so one of the common degradations in biomedical image is their noise and poor contrast. The idea of biomedical image enhancement is to improve the quality of the image for early diagnosis. In this paper we are using Wavelet Transformation to remove the Gaussian noise from biomedical images: Positron Emission Tomography (PET) image and Radiography (Radio) image, in different color spaces (RGB, HSV, YCbCr), and we perform the fusion of the denoised images resulting from the above denoising techniques using add image method. Then some quantive performance metrics such as signal -to -noise ratio (SNR), peak signal-to-noise ratio (PSNR), and Mean Square Error (MSE), etc. are computed. Since this statistical measurement helps in the assessment of fidelity and image quality. The results showed that our approach can be applied of Image types of color spaces for biomedical images.

  20. Multimodality imaging techniques.

    Science.gov (United States)

    Martí-Bonmatí, Luis; Sopena, Ramón; Bartumeus, Paula; Sopena, Pablo

    2010-01-01

    In multimodality imaging, the need to combine morphofunctional information can be approached by either acquiring images at different times (asynchronous), and fused them through digital image manipulation techniques or simultaneously acquiring images (synchronous) and merging them automatically. The asynchronous post-processing solution presents various constraints, mainly conditioned by the different positioning of the patient in the two scans acquired at different times in separated machines. The best solution to achieve consistency in time and space is obtained by the synchronous image acquisition. There are many multimodal technologies in molecular imaging. In this review we will focus on those multimodality image techniques more commonly used in the field of diagnostic imaging (SPECT-CT, PET-CT) and new developments (as PET-MR). The technological innovations and development of new tracers and smart probes are the main key points that will condition multimodality image and diagnostic imaging professionals' future. Although SPECT-CT and PET-CT are standard in most clinical scenarios, MR imaging has some advantages, providing excellent soft-tissue contrast and multidimensional functional, structural and morphological information. The next frontier is to develop efficient detectors and electronics systems capable of detecting two modality signals at the same time. Not only PET-MR but also MR-US or optic-PET will be introduced in clinical scenarios. Even more, MR diffusion-weighted, pharmacokinetic imaging, spectroscopy or functional BOLD imaging will merge with PET tracers to further increase molecular imaging as a relevant medical discipline. Multimodality imaging techniques will play a leading role in relevant clinical applications. The development of new diagnostic imaging research areas, mainly in the field of oncology, cardiology and neuropsychiatry, will impact the way medicine is performed today. Both clinical and experimental multimodality studies, in

  1. Portable Imaging Polarimeter and Imaging Experiments; TOPICAL

    International Nuclear Information System (INIS)

    PHIPPS, GARY S.; KEMME, SHANALYN A.; SWEATT, WILLIAM C.; DESCOUR, M.R.; GARCIA, J.P.; DERENIAK, E.L.

    1999-01-01

    Polarimetry is the method of recording the state of polarization of light. Imaging polarimetry extends this method to recording the spatially resolved state of polarization within a scene. Imaging-polarimetry data have the potential to improve the detection of manmade objects in natural backgrounds. We have constructed a midwave infrared complete imaging polarimeter consisting of a fixed wire-grid polarizer and rotating form-birefringent retarder. The retardance and the orientation angles of the retarder were optimized to minimize the sensitivity of the instrument to noise in the measurements. The optimal retardance was found to be 132(degree) rather than the typical 90(degree). The complete imaging polarimeter utilized a liquid-nitrogen cooled PtSi camera. The fixed wire-grid polarizer was located at the cold stop inside the camera dewar. The complete imaging polarimeter was operated in the 4.42-5(micro)m spectral range. A series of imaging experiments was performed using as targets a surface of water, an automobile, and an aircraft. Further analysis of the polarization measurements revealed that in all three cases the magnitude of circular polarization was comparable to the noise in the calculated Stokes-vector components

  2. Quantitative perfusion imaging in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Zoellner, F.G.; Gaa, T.; Zimmer, F.; Ong, M.M.; Riffel, P.; Hausmann, D.; Schoenberg, S.O.; Weis, M.

    2016-01-01

    Magnetic resonance imaging (MRI) is recognized for its superior tissue contrast while being non-invasive and free of ionizing radiation. Due to the development of new scanner hardware and fast imaging techniques during the last decades, access to tissue and organ functions became possible. One of these functional imaging techniques is perfusion imaging with which tissue perfusion and capillary permeability can be determined from dynamic imaging data. Perfusion imaging by MRI can be performed by two approaches, arterial spin labeling (ASL) and dynamic contrast-enhanced (DCE) MRI. While the first method uses magnetically labelled water protons in arterial blood as an endogenous tracer, the latter involves the injection of a contrast agent, usually gadolinium (Gd), as a tracer for calculating hemodynamic parameters. Studies have demonstrated the potential of perfusion MRI for diagnostics and also for therapy monitoring. The utilization and application of perfusion MRI are still restricted to specialized centers, such as university hospitals. A broad application of the technique has not yet been implemented. The MRI perfusion technique is a valuable tool that might come broadly available after implementation of standards on European and international levels. Such efforts are being promoted by the respective professional bodies. (orig.) [de

  3. Image Quality in High-resolution and High-cadence Solar Imaging

    Science.gov (United States)

    Denker, C.; Dineva, E.; Balthasar, H.; Verma, M.; Kuckein, C.; Diercke, A.; González Manrique, S. J.

    2018-03-01

    Broad-band imaging and even imaging with a moderate bandpass (about 1 nm) provides a photon-rich environment, where frame selection (lucky imaging) becomes a helpful tool in image restoration, allowing us to perform a cost-benefit analysis on how to design observing sequences for imaging with high spatial resolution in combination with real-time correction provided by an adaptive optics (AO) system. This study presents high-cadence (160 Hz) G-band and blue continuum image sequences obtained with the High-resolution Fast Imager (HiFI) at the 1.5-meter GREGOR solar telescope, where the speckle-masking technique is used to restore images with nearly diffraction-limited resolution. The HiFI employs two synchronized large-format and high-cadence sCMOS detectors. The median filter gradient similarity (MFGS) image-quality metric is applied, among others, to AO-corrected image sequences of a pore and a small sunspot observed on 2017 June 4 and 5. A small region of interest, which was selected for fast-imaging performance, covered these contrast-rich features and their neighborhood, which were part of Active Region NOAA 12661. Modifications of the MFGS algorithm uncover the field- and structure-dependency of this image-quality metric. However, MFGS still remains a good choice for determining image quality without a priori knowledge, which is an important characteristic when classifying the huge number of high-resolution images contained in data archives. In addition, this investigation demonstrates that a fast cadence and millisecond exposure times are still insufficient to reach the coherence time of daytime seeing. Nonetheless, the analysis shows that data acquisition rates exceeding 50 Hz are required to capture a substantial fraction of the best seeing moments, significantly boosting the performance of post-facto image restoration.

  4. Magnetic resonance imaging

    International Nuclear Information System (INIS)

    Murphy, W.A.

    1988-01-01

    After only a few years, MR imaging has proved to be an important method for imaging disorders of the musculoskeletal tissues. The images are characterized by great inherent contrast, excellent spatial resolution, and exquisite anatomic display - major reasons why MR imaging compares favorably with other imaging methods, such as radionuclide bone scanning and CT. MR imaging is particularly sensitive to bone marrow alterations and is very effective for detection and characterization of a wide variety of soft tissue conditions. Advances in surface coil technology will increase the usefulness of MR imaging in the evaluation of articular disease. In addition, chemical shift imaging and spectroscopy will add physiologic information to the anatomic features demonstrated by proton imaging

  5. Optoelectronic imaging of speckle using image processing method

    Science.gov (United States)

    Wang, Jinjiang; Wang, Pengfei

    2018-01-01

    A detailed image processing of laser speckle interferometry is proposed as an example for the course of postgraduate student. Several image processing methods were used together for dealing with optoelectronic imaging system, such as the partial differential equations (PDEs) are used to reduce the effect of noise, the thresholding segmentation also based on heat equation with PDEs, the central line is extracted based on image skeleton, and the branch is removed automatically, the phase level is calculated by spline interpolation method, and the fringe phase can be unwrapped. Finally, the imaging processing method was used to automatically measure the bubble in rubber with negative pressure which could be used in the tire detection.

  6. Review methods for image segmentation from computed tomography images

    International Nuclear Information System (INIS)

    Mamat, Nurwahidah; Rahman, Wan Eny Zarina Wan Abdul; Soh, Shaharuddin Cik; Mahmud, Rozi

    2014-01-01

    Image segmentation is a challenging process in order to get the accuracy of segmentation, automation and robustness especially in medical images. There exist many segmentation methods that can be implemented to medical images but not all methods are suitable. For the medical purposes, the aims of image segmentation are to study the anatomical structure, identify the region of interest, measure tissue volume to measure growth of tumor and help in treatment planning prior to radiation therapy. In this paper, we present a review method for segmentation purposes using Computed Tomography (CT) images. CT images has their own characteristics that affect the ability to visualize anatomic structures and pathologic features such as blurring of the image and visual noise. The details about the methods, the goodness and the problem incurred in the methods will be defined and explained. It is necessary to know the suitable segmentation method in order to get accurate segmentation. This paper can be a guide to researcher to choose the suitable segmentation method especially in segmenting the images from CT scan

  7. First Human Experience with Directly Image-able Iodinated Embolization Microbeads

    Energy Technology Data Exchange (ETDEWEB)

    Levy, Elliot B., E-mail: levyeb@cc.nih.gov; Krishnasamy, Venkatesh P. [National Institutes of Health, Center for Interventional Oncology (United States); Lewis, Andrew L.; Willis, Sean; Macfarlane, Chelsea [Biocompatibles, UK Ltd, A BTG International Group Company (United Kingdom); Anderson, Victoria [National Institutes of Health, Center for Interventional Oncology (United States); Bom, Imramsjah MJ van der [Clinical Science IGT Systems North & Latin America, Philips, Philips, Image Guided Interventions (United States); Radaelli, Alessandro [Image-Guided Therapy Systems, Philips, Philips, Image Guided Interventions (Netherlands); Dreher, Matthew R. [Biocompatibles, UK Ltd, A BTG International Group Company (United Kingdom); Sharma, Karun V. [Children’s National Medical Center (United States); Negussie, Ayele; Mikhail, Andrew S. [National Institutes of Health, Center for Interventional Oncology (United States); Geschwind, Jean-Francois H. [Department of Radiology and Biomedical Imaging (United States); Wood, Bradford J. [National Institutes of Health, Center for Interventional Oncology (United States)

    2016-08-15

    PurposeTo describe first clinical experience with a directly image-able, inherently radio-opaque microspherical embolic agent for transarterial embolization of liver tumors.MethodologyLC Bead LUMI™ is a new product based upon sulfonate-modified polyvinyl alcohol hydrogel microbeads with covalently bound iodine (~260 mg I/ml). 70–150 μ LC Bead LUMI™ iodinated microbeads were injected selectively via a 2.8 Fr microcatheter to near complete flow stasis into hepatic arteries in three patients with hepatocellular carcinoma, carcinoid, or neuroendocrine tumor. A custom imaging platform tuned for LC LUMI™ microbead conspicuity using a cone beam CT (CBCT)/angiographic C-arm system (Allura Clarity FD20, Philips) was used along with CBCT embolization treatment planning software (EmboGuide, Philips).ResultsLC Bead LUMI™ image-able microbeads were easily delivered and monitored during the procedure using fluoroscopy, single-shot radiography (SSD), digital subtraction angiography (DSA), dual-phase enhanced and unenhanced CBCT, and unenhanced conventional CT obtained 48 h after the procedure. Intra-procedural imaging demonstrated tumor at risk for potential under-treatment, defined as paucity of image-able microbeads within a portion of the tumor which was confirmed at 48 h CT imaging. Fusion of pre- and post-embolization CBCT identified vessels without beads that corresponded to enhancing tumor tissue in the same location on follow-up imaging (48 h post).ConclusionLC Bead LUMI™ image-able microbeads provide real-time feedback and geographic localization of treatment in real time during treatment. The distribution and density of image-able beads within a tumor need further evaluation as an additional endpoint for embolization.

  8. Application of image editing software for forensic detection of image ...

    African Journals Online (AJOL)

    Application of image editing software for forensic detection of image. ... The image editing software's available today is apt for creating visually compelling and sophisticated fake images, ... EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  9. BMC ecology image competition 2017: the winning images.

    Science.gov (United States)

    Foote, Christopher; Darimont, Chris T; Baguette, Michel; Blanchet, Simon; Jacobus, Luke M; Mazzi, Dominique; Settele, Josef

    2017-08-18

    For the fifth year, BMC Ecology is proud to present the winning images from our annual image competition. The 2017 edition received entries by talented shutterbug-ecologists from across the world, showcasing research that is increasing our understanding of ecosystems worldwide and the beauty and diversity of life on our planet. In this editorial we showcase the winning images, as chosen by our Editorial Board and guest judge Chris Darimont, as well as our selection of highly commended images. Enjoy!

  10. Microscopic validation of whole mouse micro-metastatic tumor imaging agents using cryo-imaging and sliding organ image registration

    OpenAIRE

    Liu, Yiqiao; Zhou, Bo; Qutaish, Mohammed; Wilson, David L.

    2016-01-01

    We created a metastasis imaging, analysis platform consisting of software and multi-spectral cryo-imaging system suitable for evaluating emerging imaging agents targeting micro-metastatic tumor. We analyzed CREKA-Gd in MRI, followed by cryo-imaging which repeatedly sectioned and tiled microscope images of the tissue block face, providing anatomical bright field and molecular fluorescence, enabling 3D microscopic imaging of the entire mouse with single metastatic cell sensitivity. To register ...

  11. Data imaging

    International Nuclear Information System (INIS)

    Pepy, G.

    1999-01-01

    After an introduction about data imaging in general, the principles of imaging data collected via neutron scattering experiments are presented. Some computer programs designed for data imaging purposes are reviewed. (K.A.)

  12. Cerenkov imaging.

    Science.gov (United States)

    Das, Sudeep; Thorek, Daniel L J; Grimm, Jan

    2014-01-01

    Cerenkov luminescence (CL) has been used recently in a plethora of medical applications like imaging and therapy with clinically relevant medical isotopes. The range of medical isotopes used is fairly large and expanding. The generation of in vivo light is useful since it circumvents depth limitations for excitation light. Cerenkov luminescence imaging (CLI) is much cheaper in terms of infrastructure than positron emission tomography (PET) and is particularly useful for imaging of superficial structures. Imaging can basically be done using a sensitive camera optimized for low-light conditions, and it has a better resolution than any other nuclear imaging modality. CLI has been shown to effectively diagnose disease with regularly used PET isotope ((18)F-FDG) in clinical setting. Cerenkov luminescence tomography, Cerenkov luminescence endoscopy, and intraoperative Cerenkov imaging have also been explored with positive conclusions expanding the current range of applications. Cerenkov has also been used to improve PET imaging resolution since the source of both is the radioisotope being used. Smart imaging agents have been designed based on modulation of the Cerenkov signal using small molecules and nanoparticles giving better insight of the tumor biology. © 2014 Elsevier Inc. All rights reserved.

  13. Imaging Human Brain Perfusion with Inhaled Hyperpolarized 129Xe MR Imaging.

    Science.gov (United States)

    Rao, Madhwesha R; Stewart, Neil J; Griffiths, Paul D; Norquay, Graham; Wild, Jim M

    2018-02-01

    Purpose To evaluate the feasibility of directly imaging perfusion of human brain tissue by using magnetic resonance (MR) imaging with inhaled hyperpolarized xenon 129 ( 129 Xe). Materials and Methods In vivo imaging with 129 Xe was performed in three healthy participants. The combination of a high-yield spin-exchange optical pumping 129 Xe polarizer, custom-built radiofrequency coils, and an optimized gradient-echo MR imaging protocol was used to achieve signal sensitivity sufficient to directly image hyperpolarized 129 Xe dissolved in the human brain. Conventional T1-weighted proton (hydrogen 1 [ 1 H]) images and perfusion images by using arterial spin labeling were obtained for comparison. Results Images of 129 Xe uptake were obtained with a signal-to-noise ratio of 31 ± 9 and demonstrated structural similarities to the gray matter distribution on conventional T1-weighted 1 H images and to perfusion images from arterial spin labeling. Conclusion Hyperpolarized 129 Xe MR imaging is an injection-free means of imaging the perfusion of cerebral tissue. The proposed method images the uptake of inhaled xenon gas to the extravascular brain tissue compartment across the intact blood-brain barrier. This level of sensitivity is not readily available with contemporary MR imaging methods. © RSNA, 2017.

  14. Erratum to: Effects of Three Types of Exercise Interventions on Healthy Old Adults' Gait Speed : A Systematic Review and Meta-Analysis (vol 45, pg 1627, 2015)

    NARCIS (Netherlands)

    Hortobagyi, Tibor; Lesinski, Melanie; Gäbler, Martijn; VanSwearingen, Jessie M.; Malatesta, Davide; Granacher, Urs

    Page 1630, column 2, section 2.3, paragraph 2, lines 15–20: The following sentence, which previously read: To determine the effectiveness of an exercise intervention in relation to gait speed, we computed between-subject effect size (ES) using the implemented formula in Review Manager version 5.3

  15. 21 CFR 177.1345 - Ethylene/1,3-phenylene oxyethylene isophthalate/ terephthalate copolymer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Ethylene/1,3-phenylene oxyethylene isophthalate... Ethylene/1,3-phenylene oxyethylene isophthalate/ terephthalate copolymer. Ethylene/1, 3-phenylene... polymers complying with § 177.1630. (a) Identity. For the purpose of this section, ethylene/1,3-phenylene...

  16. Teachers in Schools with Low Socioeconomic Composition: Are They Really That Different?

    Science.gov (United States)

    Danhier, Julien

    2016-01-01

    This article aims to assess whether differences in teacher characteristics vary with differences in socioeconomic compositions of schools. We conducted correlation analyses on administrative data from the French-speaking education system in Belgium. This database regroups more than 20,000 teachers in 1,630 elementary schools. We selected…

  17. Beyond the Individual: The Impact of Ethnic Context and Classroom Behavioral Norms on Victims' Adjustment

    Science.gov (United States)

    Bellmore, Amy D.; Witkow, Melissa R.; Graham, Sandra; Juvonen, Jaana

    2004-01-01

    With a sample of 1,630 sixth-grade students from 77 classrooms, the authors used hierarchical linear modeling to examine how ethnicity within context and classroom social disorder influenced the association between peer victimization and social-psychological adjustment (loneliness and social anxiety). Victimized students in classrooms where many…

  18. Stress wave radiation from brittle crack extension by molecular dynamics and FEM

    Czech Academy of Sciences Publication Activity Database

    Hora, Petr; Červená, Olga; Uhnáková, Alena; Machová, Anna; Pelikán, Vladimír

    2013-01-01

    Roč. 7, č. 1 (2013), s. 23-30 ISSN 1802-680X R&D Projects: GA ČR GA101/09/1630 Institutional research plan: CEZ:AV0Z20760514 Institutional support: RVO:61388998 Keywords : molecular dynamics * finite element simulation * bcc iron crystal Subject RIV: BI - Acoustic s

  19. Dispersion of strongly confined channel plasmon polariton modes

    DEFF Research Database (Denmark)

    Zenin, Vladimir; Volkov, Valentyn S.; Han, Zhanghua

    2011-01-01

    We report on experimental (by use of scanning near-field optical microscopy) and theoretical investigations of strongly confined (∼λ/5) channel plasmon polariton (CPP) modes propagating at telecom wavelengths (1425–1630 nm) along V-grooves cut in a gold film. The main CPP characteristics (mode in...

  20. Contrasting supercooling ability in lowland and mountain European Colias butterflies

    Czech Academy of Sciences Publication Activity Database

    Vrba, P.; Nedvěd, Oldřich; Konvička, Martin

    2014-01-01

    Roč. 49, č. 1 (2014), s. 63-69 ISSN 0749-8004 Grant - others:GA ČR(CZ) GAP505/10/1630; GA JU(CZ) 144/2010/100 Institutional support: RVO:60077344 Keywords : butterfly ecology * diapause * frost survival Subject RIV: EH - Ecology, Behaviour Impact factor: 0.512, year: 2014

  1. Genetic diversity and phylogeny of the Christmas Island flying fox (Pteropus melanotus natalis)

    Czech Academy of Sciences Publication Activity Database

    Phalen, D. N.; Hall, J.; Ganesh, G.; Hartigan, Ashlie; Smith, C.; De Jong, C.; Field, H.; Rose, K.

    2017-01-01

    Roč. 98, č. 2 (2017), s. 428-437 ISSN 0022-2372 Institutional support: RVO:60077344 Keywords : diversity * flying fox * mitochondrial DNA * phylogeny * Pteropus melanotus natalis Subject RIV: EB - Genetics ; Molecular Biology OBOR OECD: Genetics and heredity (medical genetics to be 3) Impact factor: 1.630, year: 2016

  2. Locks and Keys Service

    CERN Multimedia

    Claude Ducastel

    The GS-LS-SEM section is pleased to inform you that as from Monday 30 November 2009, the opening hours of the Locks and Keys service will be the following: 08h30 - 12h30 / 13h30 - 16:30, Mondays to Fridays. GS-SEM-LS 73333

  3. BLOOD DONORS CAMPAIGN

    CERN Multimedia

    2001-01-01

    A blood donors campaign, organized by the Centre de Transfusion Sanguine of Geneva will be held at CERN on Tuesday 13 March 2001 in restaurant nr 2, from 9.00 to 16.30 hrs If you already have a card giving your blood group, please bring this with you.

  4. BLOOD DONORS CAMPAIGN

    CERN Document Server

    2001-01-01

    A blood donors campaign, organized by the Centre de Transfusion d'Annemasse will be held at CERN on Tuesday 14 November 2001 in restaurant nr 2, from 9.00 to 16.30 hrs If you already have a card giving your blood group, please bring this with you.

  5. Thermal characterization of montmorillonite clays saturated with various cations

    Czech Academy of Sciences Publication Activity Database

    Balek, V.; Beneš, M.; Šubrt, Jan; Pérez, R.

    2008-01-01

    Roč. 92, č. 1 (2008), s. 191-197 ISSN 1388-6150 R&D Projects: GA MŠk LC523 Institutional research plan: CEZ:AV0Z40320502 Keywords : collapse of interlayer space * dehydration * emanation thermal analysis Subject RIV: CA - Inorganic Chemistry Impact factor: 1.630, year: 2008

  6. Tertiary Students' Entrepreneurial Career Intentions of Entrepreneurship-Embedded Internship Programs

    Science.gov (United States)

    Chou, Chun-Mei; Shen, Chien-Hua; Hsiao, Hsi-Chi; Chen, Su-Chang

    2017-01-01

    This study examines 1630 tertiary students in regard to their entrepreneurial career intentions (ECIs) and their influencing factors. The findings may serve as academic reference for the development of entrepreneurship-related education. The results show that students' computer self-efficacy (CSE) has a significant direct effect on ECIs, and…

  7. Distance between images

    Science.gov (United States)

    Gualtieri, J. A.; Le Moigne, J.; Packer, C. V.

    1992-01-01

    Comparing two binary images and assigning a quantitative measure to this comparison finds its purpose in such tasks as image recognition, image compression, and image browsing. This quantitative measurement may be computed by utilizing the Hausdorff distance of the images represented as two-dimensional point sets. In this paper, we review two algorithms that have been proposed to compute this distance, and we present a parallel implementation of one of them on the MasPar parallel processor. We study their complexity and the results obtained by these algorithms for two different types of images: a set of displaced pairs of images of Gaussian densities, and a comparison of a Canny edge image with several edge images from a hierarchical region growing code.

  8. Radiological Image Compression

    Science.gov (United States)

    Lo, Shih-Chung Benedict

    The movement toward digital images in radiology presents the problem of how to conveniently and economically store, retrieve, and transmit the volume of digital images. Basic research into image data compression is necessary in order to move from a film-based department to an efficient digital -based department. Digital data compression technology consists of two types of compression technique: error-free and irreversible. Error -free image compression is desired; however, present techniques can only achieve compression ratio of from 1.5:1 to 3:1, depending upon the image characteristics. Irreversible image compression can achieve a much higher compression ratio; however, the image reconstructed from the compressed data shows some difference from the original image. This dissertation studies both error-free and irreversible image compression techniques. In particular, some modified error-free techniques have been tested and the recommended strategies for various radiological images are discussed. A full-frame bit-allocation irreversible compression technique has been derived. A total of 76 images which include CT head and body, and radiographs digitized to 2048 x 2048, 1024 x 1024, and 512 x 512 have been used to test this algorithm. The normalized mean -square-error (NMSE) on the difference image, defined as the difference between the original and the reconstructed image from a given compression ratio, is used as a global measurement on the quality of the reconstructed image. The NMSE's of total of 380 reconstructed and 380 difference images are measured and the results tabulated. Three complex compression methods are also suggested to compress images with special characteristics. Finally, various parameters which would effect the quality of the reconstructed images are discussed. A proposed hardware compression module is given in the last chapter.

  9. 29 CFR 1630.9 - Not making reasonable accommodation.

    Science.gov (United States)

    2010-07-01

    ... assistance authorized by section 506 of the ADA, including any failure in the development or dissemination of... functions of the position held or desired, and cannot, as a result of that rejection, perform the essential functions of the position, the individual will not be considered a qualified individual with a disability. ...

  10. Acoustical holographic Siamese image technique for imaging radial cracks in reactor piping

    International Nuclear Information System (INIS)

    Collins, H.D.; Gribble, R.P.

    1985-04-01

    This paper describes a unique technique (i.e., ''Siamese imaging'') for imaging quasi-vertical defects in reactor pipe weldments. The Siamese image is a bi-symmetrical view of the inner surface defect. Image construction geometry consists of two probes (i.e., source/receiver) operating either from opposite sides or the same side of the defect to be imaged. As the probes are scanned across a lower surface connected defect, they encounter two images - first the normal upright image and then the inverted image. The final integrated image consists of two images connected along their baselines, thus we call it a ''Siamese image.'' The experimental imaging results on simulated and natural cracks in reactor piping weldments graphically illustrate this unique technique. Excellent images of mechanical fatique and thermal cracks were obtained on ferritic and austenitic piping

  11. ImagingSIMS

    Energy Technology Data Exchange (ETDEWEB)

    2017-11-06

    ImagingSIMS is an open source application for loading, processing, manipulating and visualizing secondary ion mass spectrometry (SIMS) data. At PNNL, a separate branch has been further developed to incorporate application specific features for dynamic SIMS data sets. These include loading CAMECA IMS-1280, NanoSIMS and modified IMS-4f raw data, creating isotopic ratio images and stitching together images from adjacent interrogation regions. In addition to other modifications of the parent open source version, this version is equipped with a point-by-point image registration tool to assist with streamlining the image fusion process.

  12. Characteristics of image converters and image intensifiers

    International Nuclear Information System (INIS)

    Gurvich, A.M.; Shamanov, A.A.; Rozenberg, A.M.; Fajnberg, V.S.; Kavtorova, V.P.; Salyuk, L.V.; Yakovleva, F.B.

    1978-01-01

    The characteristics of image converters and image intensifiers, which determine the range of the X-radiation dose rates used and the image quality, are considered. The equations for calculating the requirements to be imposed on the separate intensifier elements from known parameters of other elements with an allowance for the nonlinearity of the television system and the role of fluctuation in the space distribution of X-radiation quanta are given

  13. Image registration method for medical image sequences

    Science.gov (United States)

    Gee, Timothy F.; Goddard, James S.

    2013-03-26

    Image registration of low contrast image sequences is provided. In one aspect, a desired region of an image is automatically segmented and only the desired region is registered. Active contours and adaptive thresholding of intensity or edge information may be used to segment the desired regions. A transform function is defined to register the segmented region, and sub-pixel information may be determined using one or more interpolation methods.

  14. Annotating images by mining image search results.

    Science.gov (United States)

    Wang, Xin-Jing; Zhang, Lei; Li, Xirong; Ma, Wei-Ying

    2008-11-01

    Although it has been studied for years by the computer vision and machine learning communities, image annotation is still far from practical. In this paper, we propose a novel attempt at model-free image annotation, which is a data-driven approach that annotates images by mining their search results. Some 2.4 million images with their surrounding text are collected from a few photo forums to support this approach. The entire process is formulated in a divide-and-conquer framework where a query keyword is provided along with the uncaptioned image to improve both the effectiveness and efficiency. This is helpful when the collected data set is not dense everywhere. In this sense, our approach contains three steps: 1) the search process to discover visually and semantically similar search results, 2) the mining process to identify salient terms from textual descriptions of the search results, and 3) the annotation rejection process to filter out noisy terms yielded by Step 2. To ensure real-time annotation, two key techniques are leveraged-one is to map the high-dimensional image visual features into hash codes, the other is to implement it as a distributed system, of which the search and mining processes are provided as Web services. As a typical result, the entire process finishes in less than 1 second. Since no training data set is required, our approach enables annotating with unlimited vocabulary and is highly scalable and robust to outliers. Experimental results on both real Web images and a benchmark image data set show the effectiveness and efficiency of the proposed algorithm. It is also worth noting that, although the entire approach is illustrated within the divide-and conquer framework, a query keyword is not crucial to our current implementation. We provide experimental results to prove this.

  15. Image, Image, Image

    Science.gov (United States)

    Howell, Robert T.

    2004-01-01

    With all the talk today about accountability, budget cuts, and the closing of programs in public education, teachers cannot overlook the importance of image in the field of industrial technology. It is very easy for administrators to cut ITE (industrial technology education) programs to save school money--money they might shift to teaching the…

  16. Robust image registration for multiple exposure high dynamic range image synthesis

    Science.gov (United States)

    Yao, Susu

    2011-03-01

    Image registration is an important preprocessing technique in high dynamic range (HDR) image synthesis. This paper proposed a robust image registration method for aligning a group of low dynamic range images (LDR) that are captured with different exposure times. Illumination change and photometric distortion between two images would result in inaccurate registration. We propose to transform intensity image data into phase congruency to eliminate the effect of the changes in image brightness and use phase cross correlation in the Fourier transform domain to perform image registration. Considering the presence of non-overlapped regions due to photometric distortion, evolutionary programming is applied to search for the accurate translation parameters so that the accuracy of registration is able to be achieved at a hundredth of a pixel level. The proposed algorithm works well for under and over-exposed image registration. It has been applied to align LDR images for synthesizing high quality HDR images..

  17. Projection of drought-inducing climate conditions in the Czech Republic according to Euro-CORDEX models

    Czech Academy of Sciences Publication Activity Database

    Štěpánek, Petr; Zahradníček, Pavel; Farda, Aleš; Skalák, Petr; Trnka, Miroslav; Meitner, Jan; Rajdl, Kamil

    2016-01-01

    Roč. 70, 2-3 (2016), s. 179-193 ISSN 0936-577X R&D Projects: GA MŠk(CZ) LO1415; GA MŠk(CZ) LD14043; GA ČR(CZ) GA14-12262S; GA ČR GA13-19831S; GA ČR(CZ) GA16-16549S Institutional support: RVO:67179843 Keywords : Euro-CORDEX simulations * model bias correction * climate change * drought indices * Czech Republic Subject RIV: DA - Hydrology ; Limnology Impact factor: 1.578, year: 2016

  18. Drought reconstruction based on grape harvest dates for the Czech Lands, 1499−2012

    Czech Academy of Sciences Publication Activity Database

    Možný, M.; Dobrovolný, Petr; Trnka, Miroslav; Potopová, V.; Hlavinka, Petr; Bartošová, Lenka; Zahradníček, Pavel; Štěpánek, Petr; Žalud, Zdeněk

    2016-01-01

    Roč. 70, 2-3 (2016), s. 119-132 ISSN 0936-577X R&D Projects: GA MŠk(CZ) LO1415; GA ČR GA13-19831S; GA ČR GA13-04291S Grant - others:EHP(CZ) EHP-CZ02-OV-1-014-2014 Program:CZ02 Institutional support: RVO:67179843 Keywords : Climate reconstruction * Drought * Grape harvest dates * SPEI * Bohemian wine-growing region Subject RIV: DG - Athmosphere Sciences, Meteorology Impact factor: 1.578, year: 2016

  19. Evaluation of the interespecific behaviour in frogs Avaliação do comportamento interespecífico de rã, Leptodactylus labyrinthicus (rã pimenta) e Lithobates catesbeianus (rã-touro) em diferentes ambientes. DOI: 10.7902/ecb.v2i1.23

    OpenAIRE

    Patrick Oliveira de Souza; Adriano de Souza Alves; Oswaldo Pinto Ribeiro Filho; Rafael de Souza Alves; Marcelo Maia Pereira

    2011-01-01

    The experiment was conducted in Experimental Frog Federal University of Viçosa, in the period from 7 to 8 November 2010, aiming to assess the interspecific behavior of two species of frog, Leptodactylus labyrinthicus (frog-pepper) and Lithobates catesbeianus ( bullfrog) in different environments. In one stall (floor masonry) were placed 5 copies of pepper and five-frog bull-frogs with an average weight of 171.6 ± 157.8 ± 2g and 2g respectively. Bay...

  20. Hybrid single quantum well InP/Si nanobeam lasers for silicon photonics.

    Science.gov (United States)

    Fegadolli, William S; Kim, Se-Heon; Postigo, Pablo Aitor; Scherer, Axel

    2013-11-15

    We report on a hybrid InP/Si photonic crystal nanobeam laser emitting at 1578 nm with a low threshold power of ~14.7 μW. Laser gain is provided from a single InAsP quantum well embedded in a 155 nm InP layer bonded on a standard silicon-on-insulator wafer. This miniaturized nanolaser, with an extremely small modal volume of 0.375(λ/n)(3), is a promising and efficient light source for silicon photonics.

  1. Qualitative Assessment of Soil Carbon in a Rehabilitated Forest Using Fourier Transform Infrared Spectroscopy

    Directory of Open Access Journals (Sweden)

    Huck-Ywih Ch'ng

    2011-01-01

    Full Text Available Logging and poor shifting cultivation negatively affect initial soil carbon (C storage, especially at the initial stage of deforestation, as these practices lead to global warming. As a result, an afforestation program is needed to mitigate this problem. This study assessed initial soil C buildup of rehabilitated forests using Fourier transform infrared (FTIR spectroscopy. The relatively high E4/E6 values of humic acids (HAs in the rehabilitated forest indicate prominence of aliphatic components, suggesting that the HAs were of low molecular weight. The total acidity, carboxylic (-COOH and phenolic (-OH of the rehabilitated forest were found to be consistent with the ranges reported by other researchers. The spectra of all locations were similar because there was no significant difference in the quantities of C in humic acids (CHA regardless of forest age and soil depth. The spectra showed distinct absorbance at 3290, 1720, 1630, 1510, 1460, 1380, and 1270 cm-1. Increase of band at 1630 and 1510 cm-1 from 0–20 to 40–60 cm were observed, suggesting C buildup from the lowest depths 20–40 and 40–60 cm. However, the CHA content in the soil depths was not different. The band at 1630 cm-1 was assigned to carboxylic and aromatic groups. Increase in peak intensity at 1510 cm-1 was because C/N ratio increased with increasing soil depth. This indicates that decomposition rate decreased with increasing soil depth and decreased with CHA. The finding suggests that FTIR spectroscopy enables the assessment of C composition functional group buildup at different depths and ages.

  2. No-reference image quality assessment for horizontal-path imaging scenarios

    Science.gov (United States)

    Rios, Carlos; Gladysz, Szymon

    2013-05-01

    There exist several image-enhancement algorithms and tasks associated with imaging through turbulence that depend on defining the quality of an image. Examples include: "lucky imaging", choosing the width of the inverse filter for image reconstruction, or stopping iterative deconvolution. We collected a number of image quality metrics found in the literature. Particularly interesting are the blind, "no-reference" metrics. We discuss ways of evaluating the usefulness of these metrics, even when a fully objective comparison is impossible because of the lack of a reference image. Metrics are tested on simulated and real data. Field data comes from experiments performed by the NATO SET 165 research group over a 7 km distance in Dayton, Ohio.

  3. Imaging techniques and investigation protocols in pediatric emergency imaging

    International Nuclear Information System (INIS)

    Scharitzer, M.; Hoermann, M.; Puig, S.; Prokop, M.

    2002-01-01

    Paediatric emergencies demand a quick and efficient radiological investigation with special attention to specific adjustments related to patient age and radiation protection. Imaging modalities are improving rapidly and enable to diagnose childhood diseases and injuries more quickly, accurately and safely. This article provides an overview of imaging techniques adjusted to the age of the child and an overview of imaging strategies of common paediatric emergencies. Optimising the imaging parameters (digital radiography, different screen-film systems, exposure specifications) allows for substantial reduction of radiation dose. Spiral- and multislice-CT reduce scan time and enable a considerable reduction of radiation exposure if scanning parameters (pitch setting, tube current) are properly adjusted. MRI is still mainly used for neurological or spinal emergencies despite the advent of fast imaging sequences. The radiologist's task is to select an appropriate imaging strategy according to expected differential diagnosis and to adjust the imaging techniques to the individual patient. (orig.) [de

  4. Prior image constrained image reconstruction in emerging computed tomography applications

    Science.gov (United States)

    Brunner, Stephen T.

    Advances have been made in computed tomography (CT), especially in the past five years, by incorporating prior images into the image reconstruction process. In this dissertation, we investigate prior image constrained image reconstruction in three emerging CT applications: dual-energy CT, multi-energy photon-counting CT, and cone-beam CT in image-guided radiation therapy. First, we investigate the application of Prior Image Constrained Compressed Sensing (PICCS) in dual-energy CT, which has been called "one of the hottest research areas in CT." Phantom and animal studies are conducted using a state-of-the-art 64-slice GE Discovery 750 HD CT scanner to investigate the extent to which PICCS can enable radiation dose reduction in material density and virtual monochromatic imaging. Second, we extend the application of PICCS from dual-energy CT to multi-energy photon-counting CT, which has been called "one of the 12 topics in CT to be critical in the next decade." Numerical simulations are conducted to generate multiple energy bin images for a photon-counting CT acquisition and to investigate the extent to which PICCS can enable radiation dose efficiency improvement. Third, we investigate the performance of a newly proposed prior image constrained scatter correction technique to correct scatter-induced shading artifacts in cone-beam CT, which, when used in image-guided radiation therapy procedures, can assist in patient localization, and potentially, dose verification and adaptive radiation therapy. Phantom studies are conducted using a Varian 2100 EX system with an on-board imager to investigate the extent to which the prior image constrained scatter correction technique can mitigate scatter-induced shading artifacts in cone-beam CT. Results show that these prior image constrained image reconstruction techniques can reduce radiation dose in dual-energy CT by 50% in phantom and animal studies in material density and virtual monochromatic imaging, can lead to radiation

  5. Optimization of the alpha image reconstruction. An iterative CT-image reconstruction with well-defined image quality metrics

    Energy Technology Data Exchange (ETDEWEB)

    Lebedev, Sergej; Sawall, Stefan; Knaup, Michael; Kachelriess, Marc [German Cancer Research Center, Heidelberg (Germany).

    2017-10-01

    Optimization of the AIR-algorithm for improved convergence and performance. TThe AIR method is an iterative algorithm for CT image reconstruction. As a result of its linearity with respect to the basis images, the AIR algorithm possesses well defined, regular image quality metrics, e.g. point spread function (PSF) or modulation transfer function (MTF), unlike other iterative reconstruction algorithms. The AIR algorithm computes weighting images α to blend between a set of basis images that preferably have mutually exclusive properties, e.g. high spatial resolution or low noise. The optimized algorithm uses an approach that alternates between the optimization of rawdata fidelity using an OSSART like update and regularization using gradient descent, as opposed to the initially proposed AIR using a straightforward gradient descent implementation. A regularization strength for a given task is chosen by formulating a requirement for the noise reduction and checking whether it is fulfilled for different regularization strengths, while monitoring the spatial resolution using the voxel-wise defined modulation transfer function for the AIR image. The optimized algorithm computes similar images in a shorter time compared to the initial gradient descent implementation of AIR. The result can be influenced by multiple parameters that can be narrowed down to a relatively simple framework to compute high quality images. The AIR images, for instance, can have at least a 50% lower noise level compared to the sharpest basis image, while the spatial resolution is mostly maintained. The optimization improves performance by a factor of 6, while maintaining image quality. Furthermore, it was demonstrated that the spatial resolution for AIR can be determined using regular image quality metrics, given smooth weighting images. This is not possible for other iterative reconstructions as a result of their non linearity. A simple set of parameters for the algorithm is discussed that provides

  6. Optimization of the alpha image reconstruction. An iterative CT-image reconstruction with well-defined image quality metrics

    International Nuclear Information System (INIS)

    Lebedev, Sergej; Sawall, Stefan; Knaup, Michael; Kachelriess, Marc

    2017-01-01

    Optimization of the AIR-algorithm for improved convergence and performance. TThe AIR method is an iterative algorithm for CT image reconstruction. As a result of its linearity with respect to the basis images, the AIR algorithm possesses well defined, regular image quality metrics, e.g. point spread function (PSF) or modulation transfer function (MTF), unlike other iterative reconstruction algorithms. The AIR algorithm computes weighting images α to blend between a set of basis images that preferably have mutually exclusive properties, e.g. high spatial resolution or low noise. The optimized algorithm uses an approach that alternates between the optimization of rawdata fidelity using an OSSART like update and regularization using gradient descent, as opposed to the initially proposed AIR using a straightforward gradient descent implementation. A regularization strength for a given task is chosen by formulating a requirement for the noise reduction and checking whether it is fulfilled for different regularization strengths, while monitoring the spatial resolution using the voxel-wise defined modulation transfer function for the AIR image. The optimized algorithm computes similar images in a shorter time compared to the initial gradient descent implementation of AIR. The result can be influenced by multiple parameters that can be narrowed down to a relatively simple framework to compute high quality images. The AIR images, for instance, can have at least a 50% lower noise level compared to the sharpest basis image, while the spatial resolution is mostly maintained. The optimization improves performance by a factor of 6, while maintaining image quality. Furthermore, it was demonstrated that the spatial resolution for AIR can be determined using regular image quality metrics, given smooth weighting images. This is not possible for other iterative reconstructions as a result of their non linearity. A simple set of parameters for the algorithm is discussed that provides

  7. Image splitting and remapping method for radiological image compression

    Science.gov (United States)

    Lo, Shih-Chung B.; Shen, Ellen L.; Mun, Seong K.

    1990-07-01

    A new decomposition method using image splitting and gray-level remapping has been proposed for image compression, particularly for images with high contrast resolution. The effects of this method are especially evident in our radiological image compression study. In our experiments, we tested the impact of this decomposition method on image compression by employing it with two coding techniques on a set of clinically used CT images and several laser film digitized chest radiographs. One of the compression techniques used was full-frame bit-allocation in the discrete cosine transform domain, which has been proven to be an effective technique for radiological image compression. The other compression technique used was vector quantization with pruned tree-structured encoding, which through recent research has also been found to produce a low mean-square-error and a high compression ratio. The parameters we used in this study were mean-square-error and the bit rate required for the compressed file. In addition to these parameters, the difference between the original and reconstructed images will be presented so that the specific artifacts generated by both techniques can be discerned by visual perception.

  8. MRI quality control: six imagers studied using eleven unified image quality parameters

    International Nuclear Information System (INIS)

    Ihalainen, T.; Sipilae, O.; Savolainen, S.

    2004-01-01

    Quality control of the magnetic resonance imagers of different vendors in the clinical environment is non-harmonised, and comparing the performance is difficult. The purpose of this study was to develop and apply a harmonised long-term quality control protocol for the six imagers in our organisation in order to assure that they fulfil the same basic image quality requirements. The same Eurospin phantom set and identical imaging parameters were used with each imager. Values of 11 comparable parameters describing the image quality were measured. Automatic image analysis software was developed to objectively analyse the images. The results proved that the imagers were operating at a performance level adequate for clinical imaging. Some deficiencies were detected in image uniformity and geometry. The automated analysis of the Eurospin phantom images was successful. The measurements were successfully repeated after 2 weeks on one imager and after half a year on all imagers. As an objective way of examining the image quality, this kind of comparable and objective quality control of different imagers is considered as an essential step towards harmonisation of the clinical MRI studies through a large hospital organisation. (orig.)

  9. Image forming apparatus

    DEFF Research Database (Denmark)

    2005-01-01

    An image H(x, y) for displaying a target image G(x, y) is displayed on a liquid-crystal display panel and illumination light from an illumination light source is made to pass therethrough to form an image on a PALSLM. Read light hv is radiated to the PALSLM and a phase-modulated light image alpha...... (x, y) read out of the PALSLM is subjected to Fourier transform by a lens. A phase contrast filter gives a predetermined phase shift to only the zero-order light component of Fourier light image alpha f(x, y). The phase-shifted light image is subjected to inverse Fourier transform by a lens...... to project an output image O(x, y) to an output plane. A light image O'(x, y) branched by a beam sampler is picked up by a pickup device and an evaluation value calculating unit evaluates conformity between the image O(x, y) and the image G(x, y).; A control unit performs feedback control of optical...

  10. A hierarchical SVG image abstraction layer for medical imaging

    Science.gov (United States)

    Kim, Edward; Huang, Xiaolei; Tan, Gang; Long, L. Rodney; Antani, Sameer

    2010-03-01

    As medical imaging rapidly expands, there is an increasing need to structure and organize image data for efficient analysis, storage and retrieval. In response, a large fraction of research in the areas of content-based image retrieval (CBIR) and picture archiving and communication systems (PACS) has focused on structuring information to bridge the "semantic gap", a disparity between machine and human image understanding. An additional consideration in medical images is the organization and integration of clinical diagnostic information. As a step towards bridging the semantic gap, we design and implement a hierarchical image abstraction layer using an XML based language, Scalable Vector Graphics (SVG). Our method encodes features from the raw image and clinical information into an extensible "layer" that can be stored in a SVG document and efficiently searched. Any feature extracted from the raw image including, color, texture, orientation, size, neighbor information, etc., can be combined in our abstraction with high level descriptions or classifications. And our representation can natively characterize an image in a hierarchical tree structure to support multiple levels of segmentation. Furthermore, being a world wide web consortium (W3C) standard, SVG is able to be displayed by most web browsers, interacted with by ECMAScript (standardized scripting language, e.g. JavaScript, JScript), and indexed and retrieved by XML databases and XQuery. Using these open source technologies enables straightforward integration into existing systems. From our results, we show that the flexibility and extensibility of our abstraction facilitates effective storage and retrieval of medical images.

  11. Objective analysis of image quality of video image capture systems

    Science.gov (United States)

    Rowberg, Alan H.

    1990-07-01

    As Picture Archiving and Communication System (PACS) technology has matured, video image capture has become a common way of capturing digital images from many modalities. While digital interfaces, such as those which use the ACR/NEMA standard, will become more common in the future, and are preferred because of the accuracy of image transfer, video image capture will be the dominant method in the short term, and may continue to be used for some time because of the low cost and high speed often associated with such devices. Currently, virtually all installed systems use methods of digitizing the video signal that is produced for display on the scanner viewing console itself. A series of digital test images have been developed for display on either a GE CT9800 or a GE Signa MRI scanner. These images have been captured with each of five commercially available image capture systems, and the resultant images digitally transferred on floppy disk to a PC1286 computer containing Optimast' image analysis software. Here the images can be displayed in a comparative manner for visual evaluation, in addition to being analyzed statistically. Each of the images have been designed to support certain tests, including noise, accuracy, linearity, gray scale range, stability, slew rate, and pixel alignment. These image capture systems vary widely in these characteristics, in addition to the presence or absence of other artifacts, such as shading and moire pattern. Other accessories such as video distribution amplifiers and noise filters can also add or modify artifacts seen in the captured images, often giving unusual results. Each image is described, together with the tests which were performed using them. One image contains alternating black and white lines, each one pixel wide, after equilibration strips ten pixels wide. While some systems have a slew rate fast enough to track this correctly, others blur it to an average shade of gray, and do not resolve the lines, or give

  12. Predicting Visible Image Degradation by Colour Image Difference Formulae

    Institute of Scientific and Technical Information of China (English)

    Eriko Bando; Jon Y. Hardeberg; David Connah; Ivar Farup

    2004-01-01

    It carried out a CRT monitor based psychophysical experiment to investigate the quality of three colour image difference metrics, the CIEAE ab equation, the iCAM and the S-CIELAB metrics. Six original images were reproduced through six gamut mapping algorithms for the observer experiment. The result indicates that the colour image difference calculated by each metric does not directly relate to perceived image difference.

  13. An application of image processing techniques in computed tomography image analysis

    DEFF Research Database (Denmark)

    McEvoy, Fintan

    2007-01-01

    number of animals and image slices, automation of the process was desirable. The open-source and free image analysis program ImageJ was used. A macro procedure was created that provided the required functionality. The macro performs a number of basic image processing procedures. These include an initial...... process designed to remove the scanning table from the image and to center the animal in the image. This is followed by placement of a vertical line segment from the mid point of the upper border of the image to the image center. Measurements are made between automatically detected outer and inner...... boundaries of subcutaneous adipose tissue along this line segment. This process was repeated as the image was rotated (with the line position remaining unchanged) so that measurements around the complete circumference were obtained. Additionally, an image was created showing all detected boundary points so...

  14. Acoustical Imaging

    CERN Document Server

    Litniewski, Jerzy; Kujawska, Tamara; 31st International Symposium on Acoustical Imaging

    2012-01-01

    The International Symposium on Acoustical Imaging is a unique forum for advanced research, covering new technologies, developments, methods and theories in all areas of acoustics. This interdisciplinary Symposium has been taking place continuously since 1968. In the course of the years the proceedings volumes in the Acoustical Imaging Series have become a reference for cutting-edge research in the field. In 2011 the 31st International Symposium on Acoustical Imaging was held in Warsaw, Poland, April 10-13. Offering both a broad perspective on the state-of-the-art as well as  in-depth research contributions by the specialists in the field, this Volume 31 in the Series contains an excellent collection of papers in six major categories: Biological and Medical Imaging Physics and Mathematics of Acoustical Imaging Acoustic Microscopy Transducers and Arrays Nondestructive Evaluation and Industrial Applications Underwater Imaging

  15. Image quality characteristics for virtual monoenergetic images using dual-layer spectral detector CT: Comparison with conventional tube-voltage images.

    Science.gov (United States)

    Sakabe, Daisuke; Funama, Yoshinori; Taguchi, Katsuyuki; Nakaura, Takeshi; Utsunomiya, Daisuke; Oda, Seitaro; Kidoh, Masafumi; Nagayama, Yasunori; Yamashita, Yasuyuki

    2018-05-01

    To investigate the image quality characteristics for virtual monoenergetic images compared with conventional tube-voltage image with dual-layer spectral CT (DLCT). Helical scans were performed using a first-generation DLCT scanner, two different sizes of acrylic cylindrical phantoms, and a Catphan phantom. Three different iodine concentrations were inserted into the phantom center. The single-tube voltage for obtaining virtual monoenergetic images was set to 120 or 140 kVp. Conventional 120- and 140-kVp images and virtual monoenergetic images (40-200-keV images) were reconstructed from slice thicknesses of 1.0 mm. The CT number and image noise were measured for each iodine concentration and water on the 120-kVp images and virtual monoenergetic images. The noise power spectrum (NPS) was also calculated. The iodine CT numbers for the iodinated enhancing materials were similar regardless of phantom size and acquisition method. Compared with the iodine CT numbers of the conventional 120-kVp images, those for the monoenergetic 40-, 50-, and 60-keV images increased by approximately 3.0-, 1.9-, and 1.3-fold, respectively. The image noise values for each virtual monoenergetic image were similar (for example, 24.6 HU at 40 keV and 23.3 HU at 200 keV obtained at 120 kVp and 30-cm phantom size). The NPS curves of the 70-keV and 120-kVp images for a 1.0-mm slice thickness over the entire frequency range were similar. Virtual monoenergetic images represent stable image noise over the entire energy spectrum and improved the contrast-to-noise ratio than conventional tube voltage using the dual-layer spectral detector CT. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  16. Tomographic imaging

    International Nuclear Information System (INIS)

    Das, B.K.; Noreen Norfaraheen Lee Abdullah

    2012-01-01

    Tomography is used to image anatomy of organs as in the case of CT and MRI or image body functions as in the case of SPECT and PET. The theory of reconstruction applies equally well to CT, SPECT and PET with a minor differences. The main difference between SPECT and PET is that SPECT images single photon emitters (radionuclides) which emit normal gamma rays (like Tc-99m), whereas PET images positron emitting radionuclides such as O 15 or F 18 . The word tomography means drawing of the body. Every tomography results in an image of the inside of the body and is represented as a slice. (author)

  17. Image Guidance

    Science.gov (United States)

    Guidance that explains the process for getting images approved in One EPA Web microsites and resource directories. includes an appendix that shows examples of what makes some images better than others, how some images convey meaning more than others

  18. A NEW IMAGE REGISTRATION METHOD FOR GREY IMAGES

    Institute of Scientific and Technical Information of China (English)

    Nie Xuan; Zhao Rongchun; Jiang Zetao

    2004-01-01

    The proposed algorithm relies on a group of new formulas for calculating tangent slope so as to address angle feature of edge curves of image. It can utilize tangent angle features to estimate automatically and fully the rotation parameters of geometric transform and enable rough matching of images with huge rotation difference. After angle compensation, it can search for matching point sets by correlation criterion, then calculate parameters of affine transform, enable higher-precision emendation of rotation and transferring. Finally, it fulfills precise matching for images with relax-tense iteration method. Compared with the registration approach based on wavelet direction-angle features, the matching algorithm with tangent feature of image edge is more robust and realizes precise registration of various images. Furthermore, it is also helpful in graphics matching.

  19. A novel data processing technique for image reconstruction of penumbral imaging

    Science.gov (United States)

    Xie, Hongwei; Li, Hongyun; Xu, Zeping; Song, Guzhou; Zhang, Faqiang; Zhou, Lin

    2011-06-01

    CT image reconstruction technique was applied to the data processing of the penumbral imaging. Compared with other traditional processing techniques for penumbral coded pinhole image such as Wiener, Lucy-Richardson and blind technique, this approach is brand new. In this method, the coded aperture processing method was used for the first time independent to the point spread function of the image diagnostic system. In this way, the technical obstacles was overcome in the traditional coded pinhole image processing caused by the uncertainty of point spread function of the image diagnostic system. Then based on the theoretical study, the simulation of penumbral imaging and image reconstruction was carried out to provide fairly good results. While in the visible light experiment, the point source of light was used to irradiate a 5mm×5mm object after diffuse scattering and volume scattering. The penumbral imaging was made with aperture size of ~20mm. Finally, the CT image reconstruction technique was used for image reconstruction to provide a fairly good reconstruction result.

  20. Geometric correction of radiographic images using general purpose image processing program

    International Nuclear Information System (INIS)

    Kim, Eun Kyung; Cheong, Ji Seong; Lee, Sang Hoon

    1994-01-01

    The present study was undertaken to compare geometric corrected image by general-purpose image processing program for the Apple Macintosh II computer (NIH Image, Adobe Photoshop) with standardized image by individualized custom fabricated alignment instrument. Two non-standardized periapical films with XCP film holder only were taken at the lower molar portion of 19 volunteers. Two standardized periapical films with customized XCP film holder with impression material on the bite-block were taken for each person. Geometric correction was performed with Adobe Photoshop and NIH Image program. Specially, arbitrary image rotation function of 'Adobe Photoshop' and subtraction with transparency function of 'NIH Image' were utilized. The standard deviations of grey values of subtracted images were used to measure image similarity. Average standard deviation of grey values of subtracted images if standardized group was slightly lower than that of corrected group. However, the difference was found to be statistically insignificant (p>0.05). It is considered that we can use 'NIH Image' and 'Adobe Photoshop' program for correction of nonstandardized film, taken with XCP film holder at lower molar portion.

  1. Image Denoising And Segmentation Approchto Detect Tumor From BRAINMRI Images

    Directory of Open Access Journals (Sweden)

    Shanta Rangaswamy

    2018-04-01

    Full Text Available The detection of the Brain Tumor is a challenging problem, due to the structure of the Tumor cells in the brain. This project presents a systematic method that enhances the detection of brain tumor cells and to analyze functional structures by training and classification of the samples in SVM and tumor cell segmentation of the sample using DWT algorithm. From the input MRI Images collected, first noise is removed from MRI images by applying wiener filtering technique. In image enhancement phase, all the color components of MRI Images will be converted into gray scale image and make the edges clear in the image to get better identification and improvised quality of the image. In the segmentation phase, DWT on MRI Image to segment the grey-scale image is performed. During the post-processing, classification of tumor is performed by using SVM classifier. Wiener Filter, DWT, SVM Segmentation strategies were used to find and group the tumor position in the MRI filtered picture respectively. An essential perception in this work is that multi arrange approach utilizes various leveled classification strategy which supports execution altogether. This technique diminishes the computational complexity quality in time and memory. This classification strategy works accurately on all images and have achieved the accuracy of 93%.

  2. Image analysis and modeling in medical image computing. Recent developments and advances.

    Science.gov (United States)

    Handels, H; Deserno, T M; Meinzer, H-P; Tolxdorff, T

    2012-01-01

    Medical image computing is of growing importance in medical diagnostics and image-guided therapy. Nowadays, image analysis systems integrating advanced image computing methods are used in practice e.g. to extract quantitative image parameters or to support the surgeon during a navigated intervention. However, the grade of automation, accuracy, reproducibility and robustness of medical image computing methods has to be increased to meet the requirements in clinical routine. In the focus theme, recent developments and advances in the field of modeling and model-based image analysis are described. The introduction of models in the image analysis process enables improvements of image analysis algorithms in terms of automation, accuracy, reproducibility and robustness. Furthermore, model-based image computing techniques open up new perspectives for prediction of organ changes and risk analysis of patients. Selected contributions are assembled to present latest advances in the field. The authors were invited to present their recent work and results based on their outstanding contributions to the Conference on Medical Image Computing BVM 2011 held at the University of Lübeck, Germany. All manuscripts had to pass a comprehensive peer review. Modeling approaches and model-based image analysis methods showing new trends and perspectives in model-based medical image computing are described. Complex models are used in different medical applications and medical images like radiographic images, dual-energy CT images, MR images, diffusion tensor images as well as microscopic images are analyzed. The applications emphasize the high potential and the wide application range of these methods. The use of model-based image analysis methods can improve segmentation quality as well as the accuracy and reproducibility of quantitative image analysis. Furthermore, image-based models enable new insights and can lead to a deeper understanding of complex dynamic mechanisms in the human body

  3. Image Statistics

    Energy Technology Data Exchange (ETDEWEB)

    Wendelberger, Laura Jean [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-08

    In large datasets, it is time consuming or even impossible to pick out interesting images. Our proposed solution is to find statistics to quantify the information in each image and use those to identify and pick out images of interest.

  4. Adsorption characteristics of sulfur powder by bamboo charcoal to restrain sulfur allergies

    Directory of Open Access Journals (Sweden)

    Wanxi Peng

    2017-01-01

    Full Text Available Exposures to particulate matter with a diameter of 2.5 μm or less (PM2.5 may influence the risk of birth defects and make you allergic, which causes serious harm to human health. Bamboo charcoal can adsorb harmful substances,that was of benefitto people’s health. In order to figure out the optimal adsorbtion condition and the intrinsic change of bamboo charcoal, five chemicals were adsorbed by bamboo charcoal and were analyzed by FT-IR. The optimal blast time was 80 min of Na2SO3, 100 min of Na2S2O8, 20 min of Na2SO4, 120 min of Fe2(SO43 and 60 min or 100 min of S. FT-IR spectra showed that bamboo charcoal had five characteristic peaks of SS stretch, H2O stretch, OH stretch, CO stretch or CC stretch, and NO2 stretch at 3850 cm−1, 3740 cm−1, 3430 cm−1, 1630 cm−1 and 1530 cm−1, respectively. For Na2SO3, the peaks at 3850 cm−1, 3740 cm−1, 3430 cm−1, 1630 cm−1 and 1530 cm−1 achieved the maximum at 20 min. For Na2S2O8, the peaks at 3850 cm−1, 3740 cm−1, 3430 cm−1 and 1530 cm−1 achieved the maximum at 40 min. For Na2SO4, the peaks at 3850 cm−1, 3740 cm−1 and 1530 cm−1 achieved the maximum at 40 min. For Fe2(SO43, the peaks at 3850 cm−1, 3740 cm−1, 1630 cm−1 and 1530 cm−1 achieved the maximum at 120 min. For S, the peaks at 3850 cm−1 and 3740 cm−1 achieved the maximum at 40 min, the peaks at 1630 cm−1 and 1530 cm−1 achieved the maximum at 40 min. It proved that bamboo charcoal could remove sulfur powder from air to restrain sulfur allergies.

  5. A generalized framework unifying image registration and respiratory motion models and incorporating image reconstruction, for partial image data or full images

    Science.gov (United States)

    McClelland, Jamie R.; Modat, Marc; Arridge, Simon; Grimes, Helen; D'Souza, Derek; Thomas, David; O' Connell, Dylan; Low, Daniel A.; Kaza, Evangelia; Collins, David J.; Leach, Martin O.; Hawkes, David J.

    2017-06-01

    Surrogate-driven respiratory motion models relate the motion of the internal anatomy to easily acquired respiratory surrogate signals, such as the motion of the skin surface. They are usually built by first using image registration to determine the motion from a number of dynamic images, and then fitting a correspondence model relating the motion to the surrogate signals. In this paper we present a generalized framework that unifies the image registration and correspondence model fitting into a single optimization. This allows the use of ‘partial’ imaging data, such as individual slices, projections, or k-space data, where it would not be possible to determine the motion from an individual frame of data. Motion compensated image reconstruction can also be incorporated using an iterative approach, so that both the motion and a motion-free image can be estimated from the partial image data. The framework has been applied to real 4DCT, Cine CT, multi-slice CT, and multi-slice MR data, as well as simulated datasets from a computer phantom. This includes the use of a super-resolution reconstruction method for the multi-slice MR data. Good results were obtained for all datasets, including quantitative results for the 4DCT and phantom datasets where the ground truth motion was known or could be estimated.

  6. Compositional-prior-guided image reconstruction algorithm for multi-modality imaging

    Science.gov (United States)

    Fang, Qianqian; Moore, Richard H.; Kopans, Daniel B.; Boas, David A.

    2010-01-01

    The development of effective multi-modality imaging methods typically requires an efficient information fusion model, particularly when combining structural images with a complementary imaging modality that provides functional information. We propose a composition-based image segmentation method for X-ray digital breast tomosynthesis (DBT) and a structural-prior-guided image reconstruction for a combined DBT and diffuse optical tomography (DOT) breast imaging system. Using the 3D DBT images from 31 clinically measured healthy breasts, we create an empirical relationship between the X-ray intensities for adipose and fibroglandular tissue. We use this relationship to then segment another 58 healthy breast DBT images from 29 subjects into compositional maps of different tissue types. For each breast, we build a weighted-graph in the compositional space and construct a regularization matrix to incorporate the structural priors into a finite-element-based DOT image reconstruction. Use of the compositional priors enables us to fuse tissue anatomy into optical images with less restriction than when using a binary segmentation. This allows us to recover the image contrast captured by DOT but not by DBT. We show that it is possible to fine-tune the strength of the structural priors by changing a single regularization parameter. By estimating the optical properties for adipose and fibroglandular tissue using the proposed algorithm, we found the results are comparable or superior to those estimated with expert-segmentations, but does not involve the time-consuming manual selection of regions-of-interest. PMID:21258460

  7. Imaging efficacy of a targeted imaging agent for fluorescence endoscopy

    Science.gov (United States)

    Healey, A. J.; Bendiksen, R.; Attramadal, T.; Bjerke, R.; Waagene, S.; Hvoslef, A. M.; Johannesen, E.

    2008-02-01

    Colorectal cancer is a major cause of cancer death. A significant unmet clinical need exists in the area of screening for earlier and more accurate diagnosis and treatment. We have identified a fluorescence imaging agent targeted to an early stage molecular marker for colorectal cancer. The agent is administered intravenously and imaged in a far red imaging channel as an adjunct to white light endoscopy. There is experimental evidence of preclinical proof of mechanism for the agent. In order to assess potential clinical efficacy, imaging was performed with a prototype fluorescence endoscope system designed to produce clinically relevant images. A clinical laparoscope system was modified for fluorescence imaging. The system was optimised for sensitivity. Images were recorded at settings matching those expected with a clinical endoscope implementation (at video frame rate operation). The animal model was comprised of a HCT-15 xenograft tumour expressing the target at concentration levels expected in early stage colorectal cancer. Tumours were grown subcutaneously. The imaging agent was administered intravenously at a dose of 50nmol/kg body weight. The animals were killed 2 hours post administration and prepared for imaging. A 3-4mm diameter, 1.6mm thick slice of viable tumour was placed over the opened colon and imaged with the laparoscope system. A receiver operator characteristic analysis was applied to imaging results. An area under the curve of 0.98 and a sensitivity of 87% [73, 96] and specificity of 100% [93, 100] were obtained.

  8. Microwave imaging

    CERN Document Server

    Pastorino, Matteo

    2010-01-01

    An introduction to the most relevant theoretical and algorithmic aspects of modern microwave imaging approaches Microwave imaging-a technique used in sensing a given scene by means of interrogating microwaves-has recently proven its usefulness in providing excellent diagnostic capabilities in several areas, including civil and industrial engineering, nondestructive testing and evaluation, geophysical prospecting, and biomedical engineering. Microwave Imaging offers comprehensive descriptions of the most important techniques so far proposed for short-range microwave imaging-in

  9. Prevalence and predictors of vitamin a deficiency among infants in ...

    African Journals Online (AJOL)

    Vitamin A (VA) deficiency (VAD) is a major nutritional public health problem among children under-5-years-old in the developing world including Kenya. A community-based cross-sectional survey among 1,630 children (aged 6-23 mos) was undertaken in Western Kenya. A questionnaire was administered to collect ...

  10. Mediating Parent Learning to Promote Social Communication for Toddlers with Autism: Effects from a Randomized Controlled Trial

    Science.gov (United States)

    Schertz, Hannah H.; Odom, Samuel L.; Baggett, Kathleen M.; Sideris, John H.

    2018-01-01

    A randomized controlled trial was conducted to evaluate effects of the Joint Attention Mediated Learning (JAML) intervention. Toddlers with autism spectrum disorders (ASD) aged 16-30 months (n = 144) were randomized to intervention and community control conditions. Parents, who participated in 32 weekly home-based sessions, followed a mediated…

  11. Determination of total polyphenolic content in red wines by means of the combined He-Ne laser optothermal window and Folin-Ciocalteu colorimetric assay

    NARCIS (Netherlands)

    Doka, O.; Bicanic, D.

    2002-01-01

    The He-Ne laser (632.8 nm) and the concept of optothermal window (OW), a variant of the open photoacoustic cell, were combined with the Folin-Ciocalteu colorimetry assay to quantitate phenolics in four red wines. The total polyphenolic content in selected red wines varied between 786 and 1630 mg/L

  12. Ductile–brittle behavior along crack front and T-stress

    Czech Academy of Sciences Publication Activity Database

    Uhnáková, Alena; Machová, Anna; Hora, Petr

    2011-01-01

    Roč. 465, - (2011), s. 69-72 ISSN 1662-9795 R&D Projects: GA ČR(CZ) GAP108/10/0698; GA AV ČR(CZ) GA101/09/1630 Institutional research plan: CEZ:AV0Z20760514 Keywords : bcc iron * crack growth * twinning * dislocation emission Subject RIV: JG - Metallurgy

  13. Sex Discrimination after Death: A Seventeenth-Century English Study.

    Science.gov (United States)

    Doebler, Bettie Anne; Warnicke, Retha M.

    1987-01-01

    Examined funeral sermons published in England from 1601 through 1630. Found pattern of male preference; fewer funeral sermons for women. In sermon text, laudatory and idealized comments about deceased reflected and helped to perpetuate sex differences in society. Number of times sermons were reprinted did not strongly reinforce pattern of…

  14. Initial patient imaging with an optimised radiotherapy beam for portal imaging

    International Nuclear Information System (INIS)

    Flampouri, Stella; McNair, Helen A.; Donovan, Ellen M.; Evans, Philip M.; Partridge, Mike; Verhaegen, Frank; Nutting, Christopher M.

    2005-01-01

    Background and purpose: To investigate the feasibility and the advantages of a portal-imaging mode on a medical accelerator, consisting of a thin low-Z bremsstrahlung target and a thin Gd 2 O 2 S/film detector, for patient imaging. Patients and methods: The international code of practice for high-energy photon dosimetry was used to calibrate dosimetry instruments for the imaging beam produced by 4.75 MeV electrons hitting a 6 mm thick aluminium target. Images of the head and neck of a humanoid phantom were taken with a mammography film system and the dose in the phantom was measured with TLDs calibrated for this beam. The first head and neck patient images are compared with conventional images (taken with the treatment beam on a film radiotherapy verification detector). Visibility of structures for six patients was evaluated. Results: Images of the head and neck of a humanoid phantom, taken with both imaging systems showed that the contrast increased dramatically for the new system while the dose required to form an image was less than 10 -2 Gy. The patient images taken with the new and the conventional systems showed that air-tissue interfaces were better defined in the new system image. Anatomical structures, visible on both films, are clearer with the new system. Additionally, bony structures, such as vertebrae, were clearly visible only with the new system. The system under evaluation was significantly better for all features in lateral images and most features in anterior images. Conclusions: This pilot study of the new portal imaging system showed the image quality is significantly improved

  15. Hubble Space Telescope Ultraviolet Light Curves Reveal Interesting Properties of CC Sculptoris and RZ Leonis

    Energy Technology Data Exchange (ETDEWEB)

    Szkody, Paula; Mukadam, Anjum S. [Department of Astronomy, University of Washington, Box 351580, Seattle, WA 98195 (United States); Toloza, Odette; Gänsicke, Boris T.; Pala, Anna F. [Department of Physics, University of Warwick, Coventry CV4 7AL (United Kingdom); Dai, Zhibin [Yunnan Observatories, Chinese Academy of Sciences, 396 Yangfangwang, Guandu District, Kunming, 650216 (China); Waagen, Elizabeth O. [AAVSO, 48 Bay State Rd, Cambridge, MA 02138 (United States); Godon, Patrick; Sion, Edward M., E-mail: szkody@astro.washington.edu [Department of Astrophysics and Planetary Science, Villanova University, Villanova, PA 19085 (United States)

    2017-03-01

    Time-tag ultraviolet data obtained on the Hubble Space Telescope in 2013 reveal interesting variability related to the white dwarf spin in the two cataclysmic variables RZ Leo and CC Scl. RZ Leo shows a period at 220 s and its harmonic at 110 s, thus identifying it as a likely Intermediate Polar (IP). The spin signal is not visible in a short single night of ground-based data in 2016, but the shorter exposures in that data set indicate a possible partial eclipse. The much larger UV amplitude of the spin signal in the known IP CC Scl allows the spin of 389 s, previously only seen at outburst, to be visible at quiescence. Spectra created from the peaks and troughs of the spin times indicate a hotter temperature of several thousand degrees during the peak phases, with multiple components contributing to the UV light.

  16. Imaging in hematology. Part 2: Computed tomography, magnetic resonance imaging and nuclear imaging

    International Nuclear Information System (INIS)

    Zhechev, Y.

    2003-01-01

    A dramatic increase of the role of imaging in diagnosis of blood diseases occurred with the development of computed tomography (CT) and magnetic resonance imaging (MRI). At present CT of the chest, abdomen, and pelvis is routinely employed in diagnostic and staging evaluation. The bone marrow may be imaged by one of several methods, including scintigraphy, CT and MRI. Nuclear imaging at diagnosis can clarify findings of uncertain significance on conventional staging and may be very useful in the setting of large masses to follow responses to therapy nad to evaluate the residual tumor in a large mass that has responded to treatment. Recent developments such as helical CT, single proton emission computed tomography (SPECT) and positron-emission tomography (PET) have continued to advance diagnosis and therapy

  17. Extracting flat-field images from scene-based image sequences using phase correlation

    Energy Technology Data Exchange (ETDEWEB)

    Caron, James N., E-mail: Caron@RSImd.com [Research Support Instruments, 4325-B Forbes Boulevard, Lanham, Maryland 20706 (United States); Montes, Marcos J. [Naval Research Laboratory, Code 7231, 4555 Overlook Avenue, SW, Washington, DC 20375 (United States); Obermark, Jerome L. [Naval Research Laboratory, Code 8231, 4555 Overlook Avenue, SW, Washington, DC 20375 (United States)

    2016-06-15

    Flat-field image processing is an essential step in producing high-quality and radiometrically calibrated images. Flat-fielding corrects for variations in the gain of focal plane array electronics and unequal illumination from the system optics. Typically, a flat-field image is captured by imaging a radiometrically uniform surface. The flat-field image is normalized and removed from the images. There are circumstances, such as with remote sensing, where a flat-field image cannot be acquired in this manner. For these cases, we developed a phase-correlation method that allows the extraction of an effective flat-field image from a sequence of scene-based displaced images. The method uses sub-pixel phase correlation image registration to align the sequence to estimate the static scene. The scene is removed from sequence producing a sequence of misaligned flat-field images. An average flat-field image is derived from the realigned flat-field sequence.

  18. Images and society (or Images, Society and its Decoding

    Directory of Open Access Journals (Sweden)

    Juan Soto Ramírez

    2012-11-01

    Full Text Available Common sense, the thinking of the people par excellence, asserts that: a picture is worth a thousand words. This is a big mistake. The images are not carriers of meanings. The images always go through three basic processes are: production, circulation and reception. These processes are always determined in the time and social space. They are always the result of multiple relationships (social, ideological, political, moral, religious, etc., established with them. Always there are so many elements beyond the image, which determines its meaning. The meaning of an image always depends on the relationships established with it in a historical time and space, socially and culturally determined. The images are never alone. To decrypt their meanings, you must first know the symbolic life of the societies in which they appear. Images do not have a single meaning because it depends on the historical and cultural geography which presents. The images always have a close relationship with the society they were born. The Muhammad cartoons not offend everyone equally.

  19. Image sequence analysis in nuclear medicine: (1) Parametric imaging using statistical modelling

    International Nuclear Information System (INIS)

    Liehn, J.C.; Hannequin, P.; Valeyre, J.

    1989-01-01

    This is a review of parametric imaging methods on Nuclear Medicine. A Parametric Image is an image in which each pixel value is a function of the value of the same pixel of an image sequence. The Local Model Method is the fitting of each pixel time activity curve by a model which parameter values form the Parametric Images. The Global Model Method is the modelling of the changes between two images. It is applied to image comparison. For both methods, the different models, the identification criterion, the optimization methods and the statistical properties of the images are discussed. The analysis of one or more Parametric Images is performed using 1D or 2D histograms. The statistically significant Parametric Images, (Images of significant Variances, Amplitudes and Differences) are also proposed [fr

  20. Cardiac and vascular imaging with snapshot FLASH MR imaging

    International Nuclear Information System (INIS)

    Matthaei, D.; Haase, A.; Norris, D.; Leibfritz, D.; Henrich, D.; Duhmke, E.

    1989-01-01

    Acceleration of fast low-angle-shot (FLASH) MR imaging to about 200 msec measuring time on dedicated MR systems is called snapshot FLASH MR imaging. It snaps real-time series of MR images of the MR relaxation and of physiologic motions with nearly absent motion and susceptibility artifacts. Results in animals (4.7T) and human volunteers (2.0T) show plain vascular and cardiac snapshot FLASH MR images obtained as single shot, triggered reconstructed motion, or real-time films. The reduction of artifacts and the high resolution (triggered, three-dimensional moving heart images are possible) result in favorable applications in myocardial and great vascular disease

  1. NMR imaging

    International Nuclear Information System (INIS)

    Andrew, E.R.

    1983-01-01

    Since hydrogen is the most abundant element in all living organisms, proton NMR lends itself well as a method of investigation in biology and medicine. NMR imaging has some special advantages as a diagnostic tool: no ionizing radiation is used, it is noninvasive; it provides a safer means of imaging than the use of x-rays, gamma rays, positrons, or heavy ions. In contrast with ultrasound, the radiation penetrates the bony structures without attenuation. In additional to morphological information, NMR imaging provides additional diagnostic insights through relaxation parameters, which are not available from other imaging methods. In the decade since the first primitive NMR images were obtained, the quality of images now obtained approaches those from CT x-ray scanners. Prototype instruments are being constructed for clinical evaluation and the first whole-body scanners are beginning to appear on the market at costs comparable to CT scanners. Primary differences in equipment for conventional NMR and NMR imaging are the much larger aperture magnets that are required for the examination of human subjects and the addition of coils to generate field gradients and facilities for manipulating the gradients. Early results from clinical trials in many parts of the world are encouraging, and in a few years, the usefuleness of this modality of medical imaging to the medical profession in diagnosis and treatment of disease will be defined. 10 figures

  2. Progress on molecular imaging

    International Nuclear Information System (INIS)

    Chen Quan; Zhang Yongxue

    2011-01-01

    Molecular imaging is a new era of medical imaging,which can non-invasively monitor biological processes at the cellular and molecular level in vivo, including molecular imaging of nuclear medicine, magnetic resonance molecular imaging, ultrasound molecular imaging,optical molecular imaging and molecular imaging with X-ray. Recently, with the development of multi-subjects amalgamation, multimodal molecular imaging technology has been applied in clinical imaging, such as PET-CT and PET-MRI. We believe that with development of molecular probe and multi-modal imaging, more and more molecular imaging techniques will be applied in clinical diagnosis and treatment. (authors)

  3. Imaging Food Quality

    DEFF Research Database (Denmark)

    Møller, Flemming

    Imaging and spectroscopy have long been established methods for food quality control both in the laboratories and online. An ever increasing number of analytical techniques are being developed into imaging methods and existing imaging methods to contain spectral information. Images and especially...... spectral images contain large amounts of data which should be analysed appropriately by techniques combining structure and spectral information. This dissertation deals with how different types of food quality can be measured by imaging techniques, analysed with appropriate image analysis techniques...... and finally use the image data to predict or visualise food quality. A range of different food quality parameters was addressed, i.e. water distribution in bread throughout storage, time series analysis of chocolate milk stability, yoghurt glossiness, graininess and dullness and finally structure and meat...

  4. Electronic portal imaging devices

    International Nuclear Information System (INIS)

    Lief, Eugene

    2008-01-01

    The topics discussed include, among others, the following: Role of portal imaging; Port films vs. EPID; Image guidance: Elekta volume view; Delivery verification; Automation tasks of portal imaging; Types of portal imaging (Fluorescent screen, mirror, and CCD camera-based imaging; Liquid ion chamber imaging; Amorpho-silicon portal imagers; Fluoroscopic portal imaging; Kodak CR reader; and Other types of portal imaging devices); QA of EPID; and Portal dosimetry (P.A.)

  5. Remote Sensing Image Registration Using Multiple Image Features

    Directory of Open Access Journals (Sweden)

    Kun Yang

    2017-06-01

    Full Text Available Remote sensing image registration plays an important role in military and civilian fields, such as natural disaster damage assessment, military damage assessment and ground targets identification, etc. However, due to the ground relief variations and imaging viewpoint changes, non-rigid geometric distortion occurs between remote sensing images with different viewpoint, which further increases the difficulty of remote sensing image registration. To address the problem, we propose a multi-viewpoint remote sensing image registration method which contains the following contributions. (i A multiple features based finite mixture model is constructed for dealing with different types of image features. (ii Three features are combined and substituted into the mixture model to form a feature complementation, i.e., the Euclidean distance and shape context are used to measure the similarity of geometric structure, and the SIFT (scale-invariant feature transform distance which is endowed with the intensity information is used to measure the scale space extrema. (iii To prevent the ill-posed problem, a geometric constraint term is introduced into the L2E-based energy function for better behaving the non-rigid transformation. We evaluated the performances of the proposed method by three series of remote sensing images obtained from the unmanned aerial vehicle (UAV and Google Earth, and compared with five state-of-the-art methods where our method shows the best alignments in most cases.

  6. IMAGES OF DECOLONIZATION / IMAGES DE LA DECOLONISATION

    OpenAIRE

    Ganapathy-Doré , Geetha; Olinga , Michel; Crowley , Cornelius; Naumann , Michel; Le Boulicaut , Yannick; Coulardeau , Jacques; Taouchichet , Sofiane; Éric Owono Zambo , Claude; Dosoruth , Sonia; Vilar , Fernanda; Griffin , Patrick

    2013-01-01

    Il s'agit d'un document avec références.; International audience; This collected anthology of essays on the Images of Decolonization follows in the footsteps of an earlier SARI publication on Changing Images of India and Africa (Paris: L'Harmattan, 2011). It approaches the idea of decolonization from the point of view of the politics of representation with articles on the gaze of colonial and postcolonial photographers, the fantasized images of indigenous women (Pocahontas in the USA and La M...

  7. Image processing based detection of lung cancer on CT scan images

    Science.gov (United States)

    Abdillah, Bariqi; Bustamam, Alhadi; Sarwinda, Devvi

    2017-10-01

    In this paper, we implement and analyze the image processing method for detection of lung cancer. Image processing techniques are widely used in several medical problems for picture enhancement in the detection phase to support the early medical treatment. In this research we proposed a detection method of lung cancer based on image segmentation. Image segmentation is one of intermediate level in image processing. Marker control watershed and region growing approach are used to segment of CT scan image. Detection phases are followed by image enhancement using Gabor filter, image segmentation, and features extraction. From the experimental results, we found the effectiveness of our approach. The results show that the best approach for main features detection is watershed with masking method which has high accuracy and robust.

  8. The effect of image sharpness on quantitative eye movement data and on image quality evaluation while viewing natural images

    Science.gov (United States)

    Vuori, Tero; Olkkonen, Maria

    2006-01-01

    The aim of the study is to test both customer image quality rating (subjective image quality) and physical measurement of user behavior (eye movements tracking) to find customer satisfaction differences in imaging technologies. Methodological aim is to find out whether eye movements could be quantitatively used in image quality preference studies. In general, we want to map objective or physically measurable image quality to subjective evaluations and eye movement data. We conducted a series of image quality tests, in which the test subjects evaluated image quality while we recorded their eye movements. Results show that eye movement parameters consistently change according to the instructions given to the user, and according to physical image quality, e.g. saccade duration increased with increasing blur. Results indicate that eye movement tracking could be used to differentiate image quality evaluation strategies that the users have. Results also show that eye movements would help mapping between technological and subjective image quality. Furthermore, these results give some empirical emphasis to top-down perception processes in image quality perception and evaluation by showing differences between perceptual processes in situations when cognitive task varies.

  9. The Digital Image Processing And Quantitative Analysis In Microscopic Image Characterization

    International Nuclear Information System (INIS)

    Ardisasmita, M. Syamsa

    2000-01-01

    Many electron microscopes although have produced digital images, but not all of them are equipped with a supporting unit to process and analyse image data quantitatively. Generally the analysis of image has to be made visually and the measurement is realized manually. The development of mathematical method for geometric analysis and pattern recognition, allows automatic microscopic image analysis with computer. Image processing program can be used for image texture and structure periodic analysis by the application of Fourier transform. Because the development of composite materials. Fourier analysis in frequency domain become important for measure the crystallography orientation. The periodic structure analysis and crystal orientation are the key to understand many material properties like mechanical strength. stress, heat conductivity, resistance, capacitance and other material electric and magnetic properties. In this paper will be shown the application of digital image processing in microscopic image characterization and analysis in microscopic image

  10. A virtual image chain for perceived image quality of medical display

    Science.gov (United States)

    Marchessoux, Cédric; Jung, Jürgen

    2006-03-01

    This paper describes a virtual image chain for medical display (project VICTOR: granted in the 5th framework program by European commission). The chain starts from raw data of an image digitizer (CR, DR) or synthetic patterns and covers image enhancement (MUSICA by Agfa) and both display possibilities, hardcopy (film on viewing box) and softcopy (monitor). Key feature of the chain is a complete image wise approach. A first prototype is implemented in an object-oriented software platform. The display chain consists of several modules. Raw images are either taken from scanners (CR-DR) or from a pattern generator, in which characteristics of DR- CR systems are introduced by their MTF and their dose-dependent Poisson noise. The image undergoes image enhancement and comes to display. For soft display, color and monochrome monitors are used in the simulation. The image is down-sampled. The non-linear response of a color monitor is taken into account by the GOG or S-curve model, whereas the Standard Gray-Scale-Display-Function (DICOM) is used for monochrome display. The MTF of the monitor is applied on the image in intensity levels. For hardcopy display, the combination of film, printer, lightbox and viewing condition is modeled. The image is up-sampled and the DICOM-GSDF or a Kanamori Look-Up-Table is applied. An anisotropic model for the MTF of the printer is applied on the image in intensity levels. The density-dependent color (XYZ) of the hardcopy film is introduced by Look-Up-tables. Finally a Human Visual System Model is applied to the intensity images (XYZ in terms of cd/m2) in order to eliminate nonvisible differences. Comparison leads to visible differences, which are quantified by higher order image quality metrics. A specific image viewer is used for the visualization of the intensity image and the visual difference maps.

  11. Hip Imaging in Athletes: Sports Imaging Series.

    Science.gov (United States)

    Agten, Christoph A; Sutter, Reto; Buck, Florian M; Pfirrmann, Christian W A

    2016-08-01

    Hip or groin pain in athletes is common and clinical presentation is often nonspecific. Imaging is a very important diagnostic step in the work-up of athletes with hip pain. This review article provides an overview on hip biomechanics and discusses strategies for hip imaging modalities such as radiography, ultrasonography, computed tomography, and magnetic resonance (MR) imaging (MR arthrography and traction MR arthrography). The authors explain current concepts of femoroacetabular impingement and the problem of high prevalence of cam- and pincer-type morphology in asymptomatic persons. With the main focus on MR imaging, the authors present abnormalities of the hip joint and the surrounding soft tissues that can occur in athletes: intraarticular and extraarticular hip impingement syndromes, labral and cartilage disease, microinstability of the hip, myotendinous injuries, and athletic pubalgia. (©) RSNA, 2016.

  12. Image degradation characteristics and restoration based on regularization for diffractive imaging

    Science.gov (United States)

    Zhi, Xiyang; Jiang, Shikai; Zhang, Wei; Wang, Dawei; Li, Yun

    2017-11-01

    The diffractive membrane optical imaging system is an important development trend of ultra large aperture and lightweight space camera. However, related investigations on physics-based diffractive imaging degradation characteristics and corresponding image restoration methods are less studied. In this paper, the model of image quality degradation for the diffraction imaging system is first deduced mathematically based on diffraction theory and then the degradation characteristics are analyzed. On this basis, a novel regularization model of image restoration that contains multiple prior constraints is established. After that, the solving approach of the equation with the multi-norm coexistence and multi-regularization parameters (prior's parameters) is presented. Subsequently, the space-variant PSF image restoration method for large aperture diffractive imaging system is proposed combined with block idea of isoplanatic region. Experimentally, the proposed algorithm demonstrates its capacity to achieve multi-objective improvement including MTF enhancing, dispersion correcting, noise and artifact suppressing as well as image's detail preserving, and produce satisfactory visual quality. This can provide scientific basis for applications and possesses potential application prospects on future space applications of diffractive membrane imaging technology.

  13. Behaviors study of image registration algorithms in image guided radiation therapy

    International Nuclear Information System (INIS)

    Zou Lian; Hou Qing

    2008-01-01

    Objective: Study the behaviors of image registration algorithms, and analyze the elements which influence the performance of image registrations. Methods: Pre-known corresponding coordinates were appointed for reference image and moving image, and then the influence of region of interest (ROI) selection, transformation function initial parameters and coupled parameter spaces on registration results were studied with a software platform developed in home. Results: Region of interest selection had a manifest influence on registration performance. An improperly chosen ROI resulted in a bad registration. Transformation function initial parameters selection based on pre-known information could improve the accuracy of image registration. Coupled parameter spaces would enhance the dependence of image registration algorithm on ROI selection. Conclusions: It is necessary for clinic IGRT to obtain a ROI selection strategy (depending on specific commercial software) correlated to tumor sites. Three suggestions for image registration technique developers are automatic selection of the initial parameters of transformation function based on pre-known information, developing specific image registration algorithm for specific image feature, and assembling real-time image registration algorithms according to tumor sites selected by software user. (authors)

  14. A dual-view digital tomosynthesis imaging technique for improved chest imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Yuncheng; Lai, Chao-Jen; Wang, Tianpeng; Shaw, Chris C., E-mail: cshaw@mdanderson.org [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77054 (United States)

    2015-09-15

    Purpose: Digital tomosynthesis (DTS) has been shown to be useful for reducing the overlapping of abnormalities with anatomical structures at various depth levels along the posterior–anterior (PA) direction in chest radiography. However, DTS provides crude three-dimensional (3D) images that have poor resolution in the lateral view and can only be displayed with reasonable quality in the PA view. Furthermore, the spillover of high-contrast objects from off-fulcrum planes generates artifacts that may impede the diagnostic use of the DTS images. In this paper, the authors describe and demonstrate the use of a dual-view DTS technique to improve the accuracy of the reconstructed volume image data for more accurate rendition of the anatomy and slice images with improved resolution and reduced artifacts, thus allowing the 3D image data to be viewed in views other than the PA view. Methods: With the dual-view DTS technique, limited angle scans are performed and projection images are acquired in two orthogonal views: PA and lateral. The dual-view projection data are used together to reconstruct 3D images using the maximum likelihood expectation maximization iterative algorithm. In this study, projection images were simulated or experimentally acquired over 360° using the scanning geometry for cone beam computed tomography (CBCT). While all projections were used to reconstruct CBCT images, selected projections were extracted and used to reconstruct single- and dual-view DTS images for comparison with the CBCT images. For realistic demonstration and comparison, a digital chest phantom derived from clinical CT images was used for the simulation study. An anthropomorphic chest phantom was imaged for the experimental study. The resultant dual-view DTS images were visually compared with the single-view DTS images and CBCT images for the presence of image artifacts and accuracy of CT numbers and anatomy and quantitatively compared with root-mean-square-deviation (RMSD) values

  15. Technology and Manpower in the Textile Industry of the 1970's. Bulletin No. 1578.

    Science.gov (United States)

    Bureau of Labor Statistics (DOL), Washington, DC.

    This bulletin describes changes in technology in the textile industry, one of the major industries of the economy, projects their impact on productivity, employment, and occupational requirements, and discusses methods of adjustment. It is designed to partially meet the requirement of the Manpower Development and Training Act that the Secretary of…

  16. 3D ultrasound imaging for prosthesis fabrication and diagnostic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Morimoto, A.K.; Bow, W.J.; Strong, D.S. [and others

    1995-06-01

    The fabrication of a prosthetic socket for a below-the-knee amputee requires knowledge of the underlying bone structure in order to provide pressure relief for sensitive areas and support for load bearing areas. The goal is to enable the residual limb to bear pressure with greater ease and utility. Conventional methods of prosthesis fabrication are based on limited knowledge about the patient`s underlying bone structure. A 3D ultrasound imaging system was developed at Sandia National Laboratories. The imaging system provides information about the location of the bones in the residual limb along with the shape of the skin surface. Computer assisted design (CAD) software can use this data to design prosthetic sockets for amputees. Ultrasound was selected as the imaging modality. A computer model was developed to analyze the effect of the various scanning parameters and to assist in the design of the overall system. The 3D ultrasound imaging system combines off-the-shelf technology for image capturing, custom hardware, and control and image processing software to generate two types of image data -- volumetric and planar. Both volumetric and planar images reveal definition of skin and bone geometry with planar images providing details on muscle fascial planes, muscle/fat interfaces, and blood vessel definition. The 3D ultrasound imaging system was tested on 9 unilateral below-the- knee amputees. Image data was acquired from both the sound limb and the residual limb. The imaging system was operated in both volumetric and planar formats. An x-ray CT (Computed Tomography) scan was performed on each amputee for comparison. Results of the test indicate beneficial use of ultrasound to generate databases for fabrication of prostheses at a lower cost and with better initial fit as compared to manually fabricated prostheses.

  17. Megavoltage imaging with a large-area, flat-panel, amorphous silicon imager

    International Nuclear Information System (INIS)

    Antonuk, Larry E.; Yorkston, John; Huang Weidong; Sandler, Howard; Siewerdsen, Jeffrey H.; El-Mohri, Youcef

    1996-01-01

    Purpose: The creation of the first large-area, amorphous silicon megavoltage imager is reported. The imager is an engineering prototype built to serve as a stepping stone toward the creation of a future clinical prototype. The engineering prototype is described and various images demonstrating its properties are shown including the first reported patient image acquired with such an amorphous silicon imaging device. Specific limitations in the engineering prototype are reviewed and potential advantages of future, more optimized imagers of this type are presented. Methods and Materials: The imager is based on a two-dimensional, pixelated array containing amorphous silicon field-effect transistors and photodiode sensors which are deposited on a thin glass substrate. The array has a 512 x 560-pixel format and a pixel pitch of 450 μm giving an imaging area of ∼23 x 25 cm 2 . The array is used in conjunction with an overlying metal plate/phosphor screen converter as well as an electronic acquisition system. Images were acquired fluoroscopically using a megavoltage treatment machine. Results: Array and digitized film images of a variety of anthropomorphic phantoms and of a human subject are presented and compared. The information content of the array images generally appears to be at least as great as that of the digitized film images. Conclusion: Despite a variety of severe limitations in the engineering prototype, including many array defects, a relatively slow and noisy acquisition system, and the lack of a means to generate images in a radiographic manner, the prototype nevertheless generated clinically useful information. The general properties of these amorphous silicon arrays, along with the quality of the images provided by the engineering prototype, strongly suggest that such arrays could eventually form the basis of a new imaging technology for radiotherapy localization and verification. The development of a clinically useful prototype offering high

  18. Stereo imaging and random array stratified imaging for cargo radiation inspecting

    International Nuclear Information System (INIS)

    Wang Jingjin; Zeng Yu

    2003-01-01

    This paper presents a Stereo Imaging and Random Array Stratified Imaging for cargo container radiation Inspecting. By using dual-line vertical detector array scan, a stereo image of inspected cargo can be obtained and watched with virtual reality view. The random detector array has only one-row of detectors but distributed in a certain horizontal dimension randomly. To scan a cargo container with this random array detector, a 'defocused' image is obtained. By using 'anti-random focusing', one layer of the image can be focused on the background of all defocused images from other layers. A stratified X-ray image of overlapped bike wheels is presented

  19. Complex adaptation-based LDR image rendering for 3D image reconstruction

    Science.gov (United States)

    Lee, Sung-Hak; Kwon, Hyuk-Ju; Sohng, Kyu-Ik

    2014-07-01

    A low-dynamic tone-compression technique is developed for realistic image rendering that can make three-dimensional (3D) images similar to realistic scenes by overcoming brightness dimming in the 3D display mode. The 3D surround provides varying conditions for image quality, illuminant adaptation, contrast, gamma, color, sharpness, and so on. In general, gain/offset adjustment, gamma compensation, and histogram equalization have performed well in contrast compression; however, as a result of signal saturation and clipping effects, image details are removed and information is lost on bright and dark areas. Thus, an enhanced image mapping technique is proposed based on space-varying image compression. The performance of contrast compression is enhanced with complex adaptation in a 3D viewing surround combining global and local adaptation. Evaluating local image rendering in view of tone and color expression, noise reduction, and edge compensation confirms that the proposed 3D image-mapping model can compensate for the loss of image quality in the 3D mode.

  20. Stereo Vision-Based High Dynamic Range Imaging Using Differently-Exposed Image Pair

    Directory of Open Access Journals (Sweden)

    Won-Jae Park

    2017-06-01

    Full Text Available In this paper, a high dynamic range (HDR imaging method based on the stereo vision system is presented. The proposed method uses differently exposed low dynamic range (LDR images captured from a stereo camera. The stereo LDR images are first converted to initial stereo HDR images using the inverse camera response function estimated from the LDR images. However, due to the limited dynamic range of the stereo LDR camera, the radiance values in under/over-exposed regions of the initial main-view (MV HDR image can be lost. To restore these radiance values, the proposed stereo matching and hole-filling algorithms are applied to the stereo HDR images. Specifically, the auxiliary-view (AV HDR image is warped by using the estimated disparity between initial the stereo HDR images and then effective hole-filling is applied to the warped AV HDR image. To reconstruct the final MV HDR, the warped and hole-filled AV HDR image is fused with the initial MV HDR image using the weight map. The experimental results demonstrate objectively and subjectively that the proposed stereo HDR imaging method provides better performance compared to the conventional method.

  1. Modified-BRISQUE as no reference image quality assessment for structural MR images.

    Science.gov (United States)

    Chow, Li Sze; Rajagopal, Heshalini

    2017-11-01

    An effective and practical Image Quality Assessment (IQA) model is needed to assess the image quality produced from any new hardware or software in MRI. A highly competitive No Reference - IQA (NR - IQA) model called Blind/Referenceless Image Spatial Quality Evaluator (BRISQUE) initially designed for natural images were modified to evaluate structural MR images. The BRISQUE model measures the image quality by using the locally normalized luminance coefficients, which were used to calculate the image features. The modified-BRISQUE model trained a new regression model using MR image features and Difference Mean Opinion Score (DMOS) from 775 MR images. Two types of benchmarks: objective and subjective assessments were used as performance evaluators for both original and modified-BRISQUE models. There was a high correlation between the modified-BRISQUE with both benchmarks, and they were higher than those for the original BRISQUE. There was a significant percentage improvement in their correlation values. The modified-BRISQUE was statistically better than the original BRISQUE. The modified-BRISQUE model can accurately measure the image quality of MR images. It is a practical NR-IQA model for MR images without using reference images. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Breast Imaging: The Face of Imaging 3.0.

    Science.gov (United States)

    Mayo, Ray Cody; Parikh, Jay R

    2016-08-01

    In preparation for impending changes to the health care delivery and reimbursement models, the ACR has provided a roadmap for success via the Imaging 3.0 (®)platform. The authors illustrate how the field of breast imaging demonstrates the following Imaging 3.0 concepts: value, patient-centered care, clinical integration, structured reporting, outcome metrics, and radiology's role in the accountable care organization environment. Much of breast imaging's success may be adapted and adopted by other fields in radiology to ensure that all radiologists become more visible and provide the value sought by patients and payers. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  3. OBJECT-SPACE MULTI-IMAGE MATCHING OF MOBILE-MAPPING-SYSTEM IMAGE SEQUENCES

    Directory of Open Access Journals (Sweden)

    Y. C. Chen

    2012-07-01

    Full Text Available This paper proposes an object-space multi-image matching procedure of terrestrial MMS (Mobile Mapping System image sequences to determine the coordinates of an object point automatically and reliably. This image matching procedure can be applied to find conjugate points of MMS image sequences efficiently. Conventional area-based image matching methods are not reliable to deliver accurate matching results for this application due to image scale variations, viewing angle variations, and object occlusions. In order to deal with these three matching problems, an object space multi-image matching is proposed. A modified NCC (Normalized Cross Correlation coefficient is proposed to measure the similarity of image patches. A modified multi-window matching procedure will also be introduced to solve the problem of object occlusion. A coarse-to-fine procedure with a combination of object-space multi-image matching and multi-window matching is adopted. The proposed procedure has been implemented for the purpose of matching terrestrial MMS image sequences. The ratio of correct matches of this experiment was about 80 %. By providing an approximate conjugate point in an overlapping image manually, most of the incorrect matches could be fixed properly and the ratio of correct matches was improved up to 98 %.

  4. Automatic tissue image segmentation based on image processing and deep learning

    Science.gov (United States)

    Kong, Zhenglun; Luo, Junyi; Xu, Shengpu; Li, Ting

    2018-02-01

    Image segmentation plays an important role in multimodality imaging, especially in fusion structural images offered by CT, MRI with functional images collected by optical technologies or other novel imaging technologies. Plus, image segmentation also provides detailed structure description for quantitative visualization of treating light distribution in the human body when incorporated with 3D light transport simulation method. Here we used image enhancement, operators, and morphometry methods to extract the accurate contours of different tissues such as skull, cerebrospinal fluid (CSF), grey matter (GM) and white matter (WM) on 5 fMRI head image datasets. Then we utilized convolutional neural network to realize automatic segmentation of images in a deep learning way. We also introduced parallel computing. Such approaches greatly reduced the processing time compared to manual and semi-automatic segmentation and is of great importance in improving speed and accuracy as more and more samples being learned. Our results can be used as a criteria when diagnosing diseases such as cerebral atrophy, which is caused by pathological changes in gray matter or white matter. We demonstrated the great potential of such image processing and deep leaning combined automatic tissue image segmentation in personalized medicine, especially in monitoring, and treatments.

  5. Animal Detection in Natural Images: Effects of Color and Image Database

    Science.gov (United States)

    Zhu, Weina; Drewes, Jan; Gegenfurtner, Karl R.

    2013-01-01

    The visual system has a remarkable ability to extract categorical information from complex natural scenes. In order to elucidate the role of low-level image features for the recognition of objects in natural scenes, we recorded saccadic eye movements and event-related potentials (ERPs) in two experiments, in which human subjects had to detect animals in previously unseen natural images. We used a new natural image database (ANID) that is free of some of the potential artifacts that have plagued the widely used COREL images. Color and grayscale images picked from the ANID and COREL databases were used. In all experiments, color images induced a greater N1 EEG component at earlier time points than grayscale images. We suggest that this influence of color in animal detection may be masked by later processes when measuring reation times. The ERP results of go/nogo and forced choice tasks were similar to those reported earlier. The non-animal stimuli induced bigger N1 than animal stimuli both in the COREL and ANID databases. This result indicates ultra-fast processing of animal images is possible irrespective of the particular database. With the ANID images, the difference between color and grayscale images is more pronounced than with the COREL images. The earlier use of the COREL images might have led to an underestimation of the contribution of color. Therefore, we conclude that the ANID image database is better suited for the investigation of the processing of natural scenes than other databases commonly used. PMID:24130744

  6. Animal detection in natural images: effects of color and image database.

    Directory of Open Access Journals (Sweden)

    Weina Zhu

    Full Text Available The visual system has a remarkable ability to extract categorical information from complex natural scenes. In order to elucidate the role of low-level image features for the recognition of objects in natural scenes, we recorded saccadic eye movements and event-related potentials (ERPs in two experiments, in which human subjects had to detect animals in previously unseen natural images. We used a new natural image database (ANID that is free of some of the potential artifacts that have plagued the widely used COREL images. Color and grayscale images picked from the ANID and COREL databases were used. In all experiments, color images induced a greater N1 EEG component at earlier time points than grayscale images. We suggest that this influence of color in animal detection may be masked by later processes when measuring reation times. The ERP results of go/nogo and forced choice tasks were similar to those reported earlier. The non-animal stimuli induced bigger N1 than animal stimuli both in the COREL and ANID databases. This result indicates ultra-fast processing of animal images is possible irrespective of the particular database. With the ANID images, the difference between color and grayscale images is more pronounced than with the COREL images. The earlier use of the COREL images might have led to an underestimation of the contribution of color. Therefore, we conclude that the ANID image database is better suited for the investigation of the processing of natural scenes than other databases commonly used.

  7. Image Registration for PET/CT and CT Images with Particle Swarm Optimization

    International Nuclear Information System (INIS)

    Lee, Hak Jae; Kim, Yong Kwon; Lee, Ki Sung; Choi, Jong Hak; Kim, Chang Kyun; Moon, Guk Hyun; Joo, Sung Kwan; Kim, Kyeong Min; Cheon, Gi Jeong

    2009-01-01

    Image registration is a fundamental task in image processing used to match two or more images. It gives new information to the radiologists by matching images from different modalities. The objective of this study is to develop 2D image registration algorithm for PET/CT and CT images acquired by different systems at different times. We matched two CT images first (one from standalone CT and the other from PET/CT) that contain affluent anatomical information. Then, we geometrically transformed PET image according to the results of transformation parameters calculated by the previous step. We have used Affine transform to match the target and reference images. For the similarity measure, mutual information was explored. Use of particle swarm algorithm optimized the performance by finding the best matched parameter set within a reasonable amount of time. The results show good agreements of the images between PET/CT and CT. We expect the proposed algorithm can be used not only for PET/CT and CT image registration but also for different multi-modality imaging systems such as SPECT/CT, MRI/PET and so on.

  8. BMC Ecology Image Competition 2016: the winning images.

    Science.gov (United States)

    Simundza, Julia; Palmer, Matthew; Settele, Josef; Jacobus, Luke M; Hughes, David P; Mazzi, Dominique; Blanchet, Simon

    2016-08-09

    The 2016 BMC Ecology Image Competition marked another celebration of the astounding biodiversity, natural beauty, and biological interactions documented by talented ecologists worldwide. For our fourth annual competition, we welcomed guest judge Dr. Matthew Palmer of Columbia University, who chose the winning image from over 140 entries. In this editorial, we highlight the award winning images along with a selection of highly commended honorable mentions.

  9. Image superresolution of cytology images using wavelet based patch search

    Science.gov (United States)

    Vargas, Carlos; García-Arteaga, Juan D.; Romero, Eduardo

    2015-01-01

    Telecytology is a new research area that holds the potential of significantly reducing the number of deaths due to cervical cancer in developing countries. This work presents a novel super-resolution technique that couples high and low frequency information in order to reduce the bandwidth consumption of cervical image transmission. The proposed approach starts by decomposing into wavelets the high resolution images and transmitting only the lower frequency coefficients. The transmitted coefficients are used to reconstruct an image of the original size. Additional details are added by iteratively replacing patches of the wavelet reconstructed image with equivalent high resolution patches from a previously acquired image database. Finally, the original transmitted low frequency coefficients are used to correct the final image. Results show a higher signal to noise ratio in the proposed method over simply discarding high frequency wavelet coefficients or replacing directly down-sampled patches from the image-database.

  10. Photoacoustic imaging of teeth for dentine imaging and enamel characterization

    Science.gov (United States)

    Periyasamy, Vijitha; Rangaraj, Mani; Pramanik, Manojit

    2018-02-01

    Early detection of dental caries, cracks and lesions is needed to prevent complicated root canal treatment and tooth extraction procedures. Resolution of clinically used x-ray imaging is low, hence optical imaging techniques such as optical coherence tomography, fluorescence imaging, and Raman imaging are widely experimented for imaging dental structures. Photoacoustic effect is used in photon induced photoacoustic streaming technique to debride the root canal. In this study, the extracted teeth were imaged using photoacoustic tomography system at 1064 nm. The degradation of enamel and dentine is an indicator of onset of dental caries. Photoacoustic microscopy (PAM) was used to study the tooth enamel. Images were acquired using acoustic resolution PAM system. This was done to identify microscopic cracks and dental lesion at different anatomical sites (crown and cementum). The PAM tooth profile is an indicator of calcium distribution which is essential for demineralization studies.

  11. Overview of ImageCLEF 2017: information extraction from images

    OpenAIRE

    Ionescu, Bogdan; Müller, Henning; Villegas, Mauricio; Arenas, Helbert; Boato, Giulia; Dang Nguyen, Duc Tien; Dicente Cid, Yashin; Eickhoff, Carsten; Seco de Herrera, Alba G.; Gurrin, Cathal; Islam, Bayzidul; Kovalev, Vassili; Liauchuk, Vitali; Mothe, Josiane; Piras, Luca

    2017-01-01

    This paper presents an overview of the ImageCLEF 2017 evaluation campaign, an event that was organized as part of the CLEF (Conference and Labs of the Evaluation Forum) labs 2017. ImageCLEF is an ongoing initiative (started in 2003) that promotes the evaluation of technologies for annotation, indexing and retrieval for providing information access to collections of images in various usage scenarios and domains. In 2017, the 15th edition of ImageCLEF, three main tasks were proposed and one pil...

  12. European Space Imaging & Skybox Imaging

    International Nuclear Information System (INIS)

    Clark, J.; Schichor, P.

    2015-01-01

    Skybox and European Space Imaging have partnered to bring timely, Very High-Resolution imagery to customers in Europe and North Africa. Leveraging Silicon Valley ingenuity and world-class aerospace expertise, Skybox designs, builds, and operates a fleet of imaging satellites. With two satellites currently on-orbit, Skybox is quickly advancing towards a planned constellation of 24+ satellites with the potential for daily or sub-daily imaging at 70-90 cm resolution. With consistent, high-resolution imagery and video, European customers can monitor the dynamic units of human activity - cars, trucks, shipping containers, ships, aircraft, etc. - and derive valuable insights about the global economy. With multiple imaging opportunities per day, the Skybox constellation provides unprecedented access to imagery and information about critical targets that require rapid analysis. Skybox's unique capability to deliver high-definition video from space enables European customers to monitor a network of globally distributed assets with full-motion snapshots, without the need to deploy an aircraft or field team. The movement captured in these 30-90 second video windows yield unique insights that improve operational decisions. Skybox and EUSI are excited to offer a unique data source that can drive a better understanding of our world through supply chain monitoring, natural resource management, infrastructure monitoring, and crisis response. (author)

  13. Imaging windows for long-term intravital imaging: General overview and technical insights.

    Science.gov (United States)

    Alieva, Maria; Ritsma, Laila; Giedt, Randy J; Weissleder, Ralph; van Rheenen, Jacco

    2014-01-01

    Intravital microscopy is increasingly used to visualize and quantitate dynamic biological processes at the (sub)cellular level in live animals. By visualizing tissues through imaging windows, individual cells (e.g., cancer, host, or stem cells) can be tracked and studied over a time-span of days to months. Several imaging windows have been developed to access tissues including the brain, superficial fascia, mammary glands, liver, kidney, pancreas, and small intestine among others. Here, we review the development of imaging windows and compare the most commonly used long-term imaging windows for cancer biology: the cranial imaging window, the dorsal skin fold chamber, the mammary imaging window, and the abdominal imaging window. Moreover, we provide technical details, considerations, and trouble-shooting tips on the surgical procedures and microscopy setups for each imaging window and explain different strategies to assure imaging of the same area over multiple imaging sessions. This review aims to be a useful resource for establishing the long-term intravital imaging procedure.

  14. Identifying Image Manipulation Software from Image Features

    Science.gov (United States)

    2015-03-26

    scales”. Educational and Psychological Measurement, 20(1):37, 1960. 7. Committee, Technical Standardization. Exchangeable image file format for digital...Digital Forensics. Springer, 2005. 23. Photography, Technical Committee. Photography and graphic technology - Ex- tended colour encodings for digital image

  15. Digital image transformation and rectification of spacecraft and radar images

    Science.gov (United States)

    Wu, S. S. C.

    1985-01-01

    The application of digital processing techniques to spacecraft television pictures and radar images is discussed. The use of digital rectification to produce contour maps from spacecraft pictures is described; images with azimuth and elevation angles are converted into point-perspective frame pictures. The digital correction of the slant angle of radar images to ground scale is examined. The development of orthophoto and stereoscopic shaded relief maps from digital terrain and digital image data is analyzed. Digital image transformations and rectifications are utilized on Viking Orbiter and Lander pictures of Mars.

  16. Optimization of super-resolution processing using incomplete image sets in PET imaging.

    Science.gov (United States)

    Chang, Guoping; Pan, Tinsu; Clark, John W; Mawlawi, Osama R

    2008-12-01

    Super-resolution (SR) techniques are used in PET imaging to generate a high-resolution image by combining multiple low-resolution images that have been acquired from different points of view (POVs). The number of low-resolution images used defines the processing time and memory storage necessary to generate the SR image. In this paper, the authors propose two optimized SR implementations (ISR-1 and ISR-2) that require only a subset of the low-resolution images (two sides and diagonal of the image matrix, respectively), thereby reducing the overall processing time and memory storage. In an N x N matrix of low-resolution images, ISR-1 would be generated using images from the two sides of the N x N matrix, while ISR-2 would be generated from images across the diagonal of the image matrix. The objective of this paper is to investigate whether the two proposed SR methods can achieve similar performance in contrast and signal-to-noise ratio (SNR) as the SR image generated from a complete set of low-resolution images (CSR) using simulation and experimental studies. A simulation, a point source, and a NEMA/IEC phantom study were conducted for this investigation. In each study, 4 (2 x 2) or 16 (4 x 4) low-resolution images were reconstructed from the same acquired data set while shifting the reconstruction grid to generate images from different POVs. SR processing was then applied in each study to combine all as well as two different subsets of the low-resolution images to generate the CSR, ISR-1, and ISR-2 images, respectively. For reference purpose, a native reconstruction (NR) image using the same matrix size as the three SR images was also generated. The resultant images (CSR, ISR-1, ISR-2, and NR) were then analyzed using visual inspection, line profiles, SNR plots, and background noise spectra. The simulation study showed that the contrast and the SNR difference between the two ISR images and the CSR image were on average 0.4% and 0.3%, respectively. Line profiles of

  17. Detection of brain metastasis. Comparison of Turbo-FLAIR imaging, T2-weighted imaging and double-dose gadolinium-enhanced MR imaging

    International Nuclear Information System (INIS)

    Okubo, Toshiyuki; Hayashi, Naoto; Shirouzu, Ichiro; Abe, Osamu; Ohtomo, Kuni; Sasaki, Yasuhito; Aoki, Shigeki; Wada, Akihiko

    1998-01-01

    The purpose of this study was to compare Turbo-FLAIR imaging, T 2 -weighted imaging, and double-dose gadolinium-enhanced MR imaging in the detection of brain metastasis. Using the three sequences, 20 consecutive patients with brain metastases were prospectively studied with a 1.5-Tesla system. Three independent, blinded readers assessed the images for the presence, size, number, and location of metastatic lesions. In the detection of large lesions (>0.5 cm), Turbo-FLAIR imaging (38/48, 79%) was not significantly different from gadolinium-enhanced imaging (42/48, 88%) (p=0.273). T 2 -weighted imaging (31/48, 65%), however, was inferior to gadolinium-enhanced imaging (p<0.05). There was no difference between Turbo-FLAIR imaging and gadolinium-enhanced imaging in the accuracy of detecting solitary brain metastasis (4/4, 100%). In conclusion, Turbo-FLAIR imaging is a useful, noninvasive screening modality for brain metastasis. Its use may lead to cost savings in the diagnosis of brain metastases and may impact positively the cost-effectiveness of treatment. (author)

  18. COLOR IMAGES

    Directory of Open Access Journals (Sweden)

    Dominique Lafon

    2011-05-01

    Full Text Available The goal of this article is to present specific capabilities and limitations of the use of color digital images in a characterization process. The whole process is investigated, from the acquisition of digital color images to the analysis of the information relevant to various applications in the field of material characterization. A digital color image can be considered as a matrix of pixels with values expressed in a vector-space (commonly 3 dimensional space whose specificity, compared to grey-scale images, is to ensure a coding and a representation of the output image (visualisation printing that fits the human visual reality. In a characterization process, it is interesting to regard color image attnbutes as a set of visual aspect measurements on a material surface. Color measurement systems (spectrocolorimeters, colorimeters and radiometers and cameras use the same type of light detectors: most of them use Charge Coupled Devices sensors. The difference between the two types of color data acquisition systems is that color measurement systems provide a global information of the observed surface (average aspect of the surface: the color texture is not taken into account. Thus, it seems interesting to use imaging systems as measuring instruments for the quantitative characterization of the color texture.

  19. Bartholomeus van der Helst (1613-1670): een studie naar zijn leven en zijn werk

    NARCIS (Netherlands)

    van Gent, J.F.J.M.

    2011-01-01

    Bartholomeus van der Helst was a leading portrait painter in the Northern Netherlands in the 17th century. This monograph reconstructs his career and his circle of patrons based on the surviving works and documents. Van der Helst was born in Haarlem around 1613. In the early 1630s he moved to

  20. Reverse altitudinal cline in cold hardiness among Erebia butterflies

    Czech Academy of Sciences Publication Activity Database

    Vrba, Pavel; Konvička, Martin; Nedvěd, Oldřich

    2012-01-01

    Roč. 33, č. 4 (2012), s. 251-258 ISSN 0143-2044 Grant - others:GA ČR(CZ) GAP505/10/1630; University of South Bohemia(CZ) 144/2010/100 Institutional support: RVO:60077344 Keywords : Alpine habitats * butterfly ecology * climate change Subject RIV: EH - Ecology, Behaviour Impact factor: 0.837, year: 2012

  1. 7 CFR 1.640 - What are the requirements for prehearing conferences?

    Science.gov (United States)

    2010-01-01

    ... and the schedule of remaining steps in the hearing process. (e) Failure to attend. Unless the ALJ... prehearing conference with the parties at the time specified in the docketing notice under § 1.630, on or... exclude issues that do not qualify for review as factual, material, and disputed; (ii) To consider the...

  2. BLOOD DONORS CAMPAIGN

    CERN Document Server

    2000-01-01

    A blood donors campaign, organized by the Établissement de Transfusion de Rhône-Alpes will be held at CERN on Tuesday 14 November 2000 in restaurant nr 2, from 8.30 to 16.30 hrs If you already have a card giving your blood group, please bring this with you.

  3. Artificial intelligence and medical imaging. Expert systems and image analysis

    International Nuclear Information System (INIS)

    Wackenheim, A.; Zoellner, G.; Horviller, S.; Jacqmain, T.

    1987-01-01

    This paper gives an overview on the existing systems for automated image analysis and interpretation in medical imaging, especially in radiology. The example of ORFEVRE, the system for the analysis of CAT-scan images of the cervical triplet (c3-c5) by image analysis and subsequent expert-system is given and discussed in detail. Possible extensions are described [fr

  4. Ultrasound and PET-CT image fusion for prostate brachytherapy image guidance

    International Nuclear Information System (INIS)

    Hasford, F.

    2015-01-01

    Fusion of medical images between different cross-sectional modalities is widely used, mostly where functional images are fused with anatomical data. Ultrasound has for some time now been the standard imaging technique used for treatment planning of prostate cancer cases. While this approach is laudable and has yielded some positive results, latest developments have been the integration of images from ultrasound and other modalities such as PET-CT to compliment missing properties of ultrasound images. This study has sought to enhance diagnosis and treatment of prostate cancers by developing MATLAB algorithms to fuse ultrasound and PET-CT images. The fused ultrasound-PET-CT image has shown to contain improved quality of information than the individual input images. The fused image has the property of reduced uncertainty, increased reliability, robust system performance, and compact representation of information. The objective of co-registering the ultrasound and PET-CT images was achieved by conducting performance evaluation of the ultrasound and PET-CT imaging systems, developing image contrast enhancement algorithm, developing MATLAB image fusion algorithm, and assessing accuracy of the fusion algorithm. Performance evaluation of the ultrasound brachytherapy system produced satisfactory results in accordance with set tolerances as recommended by AAPM TG 128. Using an ultrasound brachytherapy quality assurance phantom, average axial distance measurement of 10.11 ± 0.11 mm was estimated. Average lateral distance measurements of 10.08 ± 0.07 mm, 20.01 ± 0.06 mm, 29.89 ± 0.03 mm and 39.84 ± 0.37 mm were estimated for the inter-target distances corresponding to 10 mm, 20 mm, 30 mm and 40 mm respectively. Volume accuracy assessment produced measurements of 3.97 cm 3 , 8.86 cm 3 and 20.11 cm 3 for known standard volumes of 4 cm 3 , 9 cm 3 and 20 cm 3 respectively. Depth of penetration assessment of the ultrasound system produced an estimate of 5.37 ± 0.02 cm

  5. Color-Based Image Retrieval from High-Similarity Image Databases

    DEFF Research Database (Denmark)

    Hansen, Michael Adsetts Edberg; Carstensen, Jens Michael

    2003-01-01

    Many image classification problems can fruitfully be thought of as image retrieval in a "high similarity image database" (HSID) characterized by being tuned towards a specific application and having a high degree of visual similarity between entries that should be distinguished. We introduce...... a method for HSID retrieval using a similarity measure based on a linear combination of Jeffreys-Matusita (JM) distances between distributions of color (and color derivatives) estimated from a set of automatically extracted image regions. The weight coefficients are estimated based on optimal retrieval...... performance. Experimental results on the difficult task of visually identifying clones of fungal colonies grown in a petri dish and categorization of pelts show a high retrieval accuracy of the method when combined with standardized sample preparation and image acquisition....

  6. Fast single image dehazing based on image fusion

    Science.gov (United States)

    Liu, Haibo; Yang, Jie; Wu, Zhengping; Zhang, Qingnian

    2015-01-01

    Images captured in foggy weather conditions often fade the colors and reduce the contrast of the observed objects. An efficient image fusion method is proposed to remove haze from a single input image. First, the initial medium transmission is estimated based on the dark channel prior. Second, the method adopts an assumption that the degradation level affected by haze of each region is the same, which is similar to the Retinex theory, and uses a simple Gaussian filter to get the coarse medium transmission. Then, pixel-level fusion is achieved between the initial medium transmission and coarse medium transmission. The proposed method can recover a high-quality haze-free image based on the physical model, and the complexity of the proposed method is only a linear function of the number of input image pixels. Experimental results demonstrate that the proposed method can allow a very fast implementation and achieve better restoration for visibility and color fidelity compared to some state-of-the-art methods.

  7. Syntheses and study on nickel(II) complexes with thiodiglycolic acid and nitrogen-donor ligands. X-ray structures of [Ni(bpy)(tdga)(H2O)] . 4H2O and [(en)Ni(µ-tdga)2Ni(en)] . 4H2O (tdgaH2=thiodiglycolic acid)

    Czech Academy of Sciences Publication Activity Database

    Kopel, P.; Trávníček, Zdeněk; Marek, J.; Mrozinski, J.

    2004-01-01

    Roč. 23, č. 9 (2004), s. 1573-1578 ISSN 0277-5387 R&D Projects: GA ČR(CZ) GA203/02/0436 Grant - others:GA MŠk1(CZ) MSM 153100007; GA MŠK1(CZ) MSM 143100008; Polish State Committee for Scientific Research(PL) 4T09A 11523 Institutional research plan: CEZ:AV0Z5038910 Keywords : nickel(II) * thiodiglycolic acid complexes * X-ray structures Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 1.586, year: 2004

  8. Geometrical Meaning of Arithmetic Series [Image Omitted], [Image Omitted] and [Image Omitted] in Terms of the Elementary Combinatorics

    Science.gov (United States)

    Kobayashi, Yukio

    2011-01-01

    The formula [image omitted] is closely related to combinatorics through an elementary geometric exercise. This approach can be expanded to the formulas [image omitted], [image omitted] and [image omitted]. These formulas are also nice examples of showing two approaches, one algebraic and one combinatoric, to a problem of counting. (Contains 6…

  9. CISS MR imaging findings of epidermoid tumor : comparison with spin-echo images

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Woo; Kim, Hak Jin; Choi, Sang Yoel; Heo, Jin Sam; Jung, Hoon Sik; Lee, Suck Hong; Kim, Byung Soo [Pusan National Univ. College of Medicine, Pusan (Korea, Republic of); Lee, Jong Wha [Ulsan Univ. Hospital, Ulsan (Korea, Republic of)

    1999-03-01

    To evaluate CISS MR imaging findings of epidermoid tumor in comparison with conventional spin-echo images. We studied 6 cases of epidermoid tumor in the subarachnoid space. We used a 1.5T MR unit to obtain CISS images(TR/TE/FA ; 12.3msec/5.9 msec/700) and T1- and T2- weighted spin-echo images. CISS MR imaging findings were evaluated with respect to tumor's signal intensity , contour, and relation with adjacent structures. Conspicuity of the tumor was compared between CISS and spin-echo images. A quantitative analysis was performed by measuring tumor to CSF contrast. In qualitative analysis, three radiologists independently compared CISS image and conventional spin-echo images for visibility of the tumor and graded them into three categories( poor, good, and excellent). Epidermoid tumors were located in the cerebellopontine angle in 4 cases, the prepontine cisstern in 1 case, and the cerebellopontine angle-prepontine cistern in 1 case. The tumors were hyperintense relative to brain parenchyma and hypointense relative to CSF on CISS images, were lobulated, encased adjacent cranial nerve and vessels, and invaginated into brain parenchyma. In qualitative analysis, CISS images showed clear demarcation between tumor and CSF, exact tumor extension, and tumor's relation with cranial nerves and vessels better than conventional spin-echo images. In quantitative analysis, the mean contrast values of tumor to CSF on T1-, T2-weighted images, and CISS images were 0.12, 0.06, and 0.52, respectively. The contrast value for CISS images was significantly higher than that for T1-and T2-weighted images(p<0.05). Epidermoid tumors in the subarachnoid space are better demonstrated on CISS images than on conventional spin-echo images. This special MR sequence can be added as a routine protocol in the diagnosis of subarachnoid epidermoid tumor.

  10. Imaging of Muscle Injuries in Sports Medicine: Sports Imaging Series.

    Science.gov (United States)

    Guermazi, Ali; Roemer, Frank W; Robinson, Philip; Tol, Johannes L; Regatte, Ravindar R; Crema, Michel D

    2017-03-01

    In sports-related muscle injuries, the main goal of the sports medicine physician is to return the athlete to competition-balanced against the need to prevent the injury from worsening or recurring. Prognosis based on the available clinical and imaging information is crucial. Imaging is crucial to confirm and assess the extent of sports-related muscle injuries and may help to guide management, which directly affects the prognosis. This is especially important when the diagnosis or grade of injury is unclear, when recovery is taking longer than expected, and when interventional or surgical management may be necessary. Several imaging techniques are widely available, with ultrasonography and magnetic resonance imaging currently the most frequently applied in sports medicine. This state of the art review will discuss the main imaging modalities for the assessment of sports-related muscle injuries, including advanced imaging techniques, with the focus on the clinical relevance of imaging features of muscle injuries. © RSNA, 2017 Online supplemental material is available for this article.

  11. Detail Enhancement for Infrared Images Based on Propagated Image Filter

    Directory of Open Access Journals (Sweden)

    Yishu Peng

    2016-01-01

    Full Text Available For displaying high-dynamic-range images acquired by thermal camera systems, 14-bit raw infrared data should map into 8-bit gray values. This paper presents a new method for detail enhancement of infrared images to display the image with a relatively satisfied contrast and brightness, rich detail information, and no artifacts caused by the image processing. We first adopt a propagated image filter to smooth the input image and separate the image into the base layer and the detail layer. Then, we refine the base layer by using modified histogram projection for compressing. Meanwhile, the adaptive weights derived from the layer decomposition processing are used as the strict gain control for the detail layer. The final display result is obtained by recombining the two modified layers. Experimental results on both cooled and uncooled infrared data verify that the proposed method outperforms the method based on log-power histogram modification and bilateral filter-based detail enhancement in both detail enhancement and visual effect.

  12. Single-photon imaging

    International Nuclear Information System (INIS)

    Seitz, Peter; Theuwissen, Albert J.P.

    2011-01-01

    The acquisition and interpretation of images is a central capability in almost all scientific and technological domains. In particular, the acquisition of electromagnetic radiation, in the form of visible light, UV, infrared, X-ray, etc. is of enormous practical importance. The ultimate sensitivity in electronic imaging is the detection of individual photons. With this book, the first comprehensive review of all aspects of single-photon electronic imaging has been created. Topics include theoretical basics, semiconductor fabrication, single-photon detection principles, imager design and applications of different spectral domains. Today, the solid-state fabrication capabilities for several types of image sensors has advanced to a point, where uncooled single-photon electronic imaging will soon become a consumer product. This book is giving a specialist's view from different domains to the forthcoming ''single-photon imaging'' revolution. The various aspects of single-photon imaging are treated by internationally renowned, leading scientists and technologists who have all pioneered their respective fields. (orig.)

  13. Image ranking in video sequences using pairwise image comparisons and temporal smoothing

    CSIR Research Space (South Africa)

    Burke, Michael

    2016-12-01

    Full Text Available The ability to predict the importance of an image is highly desirable in computer vision. This work introduces an image ranking scheme suitable for use in video or image sequences. Pairwise image comparisons are used to determine image ‘interest...

  14. Emerging images

    KAUST Repository

    Mitra, Niloy J.

    2009-01-01

    Emergence refers to the unique human ability to aggregate information from seemingly meaningless pieces, and to perceive a whole that is meaningful. This special skill of humans can constitute an effective scheme to tell humans and machines apart. This paper presents a synthesis technique to generate images of 3D objects that are detectable by humans, but difficult for an automatic algorithm to recognize. The technique allows generating an infinite number of images with emerging figures. Our algorithm is designed so that locally the synthesized images divulge little useful information or cues to assist any segmentation or recognition procedure. Therefore, as we demonstrate, computer vision algorithms are incapable of effectively processing such images. However, when a human observer is presented with an emergence image, synthesized using an object she is familiar with, the figure emerges when observed as a whole. We can control the difficulty level of perceiving the emergence effect through a limited set of parameters. A procedure that synthesizes emergence images can be an effective tool for exploring and understanding the factors affecting computer vision techniques. © 2009 ACM.

  15. Improvement of temporal and dynamic subtraction images on abdominal CT using 3D global image matching and nonlinear image warping techniques

    International Nuclear Information System (INIS)

    Okumura, E; Sanada, S; Suzuki, M; Takemura, A; Matsui, O

    2007-01-01

    Accurate registration of the corresponding non-enhanced and arterial-phase CT images is necessary to create temporal and dynamic subtraction images for the enhancement of subtle abnormalities. However, respiratory movement causes misregistration at the periphery of the liver. To reduce these misregistration errors, we developed a temporal and dynamic subtraction technique to enhance small HCC by 3D global matching and nonlinear image warping techniques. The study population consisted of 21 patients with HCC. Using the 3D global matching and nonlinear image warping technique, we registered current and previous arterial-phase CT images or current non-enhanced and arterial-phase CT images obtained in the same position. The temporal subtraction image was obtained by subtracting the previous arterial-phase CT image from the warped current arterial-phase CT image. The dynamic subtraction image was obtained by the subtraction of the current non-enhanced CT image from the warped current arterial-phase CT image. The percentage of fair or superior temporal subtraction images increased from 52.4% to 95.2% using the new technique, while on the dynamic subtraction images, the percentage increased from 66.6% to 95.2%. The new subtraction technique may facilitate the diagnosis of subtle HCC based on the superior ability of these subtraction images to show nodular and/or ring enhancement

  16. Performance Analysis of Segmentation of Hyperspectral Images Based on Color Image Segmentation

    Directory of Open Access Journals (Sweden)

    Praveen Agarwal

    2017-06-01

    Full Text Available Image segmentation is a fundamental approach in the field of image processing and based on user’s application .This paper propose an original and simple segmentation strategy based on the EM approach that resolves many informatics problems about hyperspectral images which are observed by airborne sensors. In a first step, to simplify the input color textured image into a color image without texture. The final segmentation is simply achieved by a spatially color segmentation using feature vector with the set of color values contained around the pixel to be classified with some mathematical equations. The spatial constraint allows taking into account the inherent spatial relationships of any image and its color. This approach provides effective PSNR for the segmented image. These results have the better performance as the segmented images are compared with Watershed & Region Growing Algorithm and provide effective segmentation for the Spectral Images & Medical Images.

  17. Image registration for a UV-Visible dual-band imaging system

    Science.gov (United States)

    Chen, Tao; Yuan, Shuang; Li, Jianping; Xing, Sheng; Zhang, Honglong; Dong, Yuming; Chen, Liangpei; Liu, Peng; Jiao, Guohua

    2018-06-01

    The detection of corona discharge is an effective way for early fault diagnosis of power equipment. UV-Visible dual-band imaging can detect and locate corona discharge spot at all-weather condition. In this study, we introduce an image registration protocol for this dual-band imaging system. The protocol consists of UV image denoising and affine transformation model establishment. We report the algorithm details of UV image preprocessing, affine transformation model establishment and relevant experiments for verification of their feasibility. The denoising algorithm was based on a correlation operation between raw UV images, a continuous mask and the transformation model was established by using corner feature and a statistical method. Finally, an image fusion test was carried out to verify the accuracy of affine transformation model. It has proved the average position displacement error between corona discharge and equipment fault at different distances in a 2.5m-20 m range are 1.34 mm and 1.92 mm in the horizontal and vertical directions, respectively, which are precise enough for most industrial applications. The resultant protocol is not only expected to improve the efficiency and accuracy of such imaging system for locating corona discharge spot, but also supposed to provide a more generalized reference for the calibration of various dual-band imaging systems in practice.

  18. In-Between-Images

    DEFF Research Database (Denmark)

    Fausing, Bent

    2013-01-01

    Article about Fascination, Affect, Interaction and Sensoric Images in Digital Culture and New Technology. I come up with a new term - 'In-Between-Images', which are the images created in between the perceiver and the perceived. We are active and interactive with these images, which are created out...

  19. Flow imaging of the cardiovascular system using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Imai, Hitoshi; Sakakibara, Makoto; Sunami, Yuko

    1988-01-01

    Blood flow images by magnetic resonance imaging (MRI) using a 0.25 T unit were evaluated for nine normal volunteers and 108 subjects with a variety of cardiovascular abnormalities. Using the non-gated short-spin echo (SE) technique, blood flow in the cardiovascular systems was not imaged in the normal volunteers. Using end-systolic and end-diastolic SE techniques for the normal subjects, blood flow in the cardiac chambers was not clearly imaged. Blood flow in the ascending aorta and aortic arch often did not appear in the gated SE images of the normal subjects. However, blood flow in the descending aorta was often observed in the gated SE images. Blood flow imaging was demonstrated by both non-gated and gated SE techniques in regions where blood flow was relatively slow; for example, in the left atrium of mitral stenosis, in an aortic aneurysm, in a false lumen of an aortic dissection, and in the left ventricle having old myocardial infarction. Using the non-gated inversion recovery (IR) technique, no blood flow was imaged in the cardiovascular system except in the left atrium of one case with mitral stenosis. Using the non-gated short SE technique, there was good correlation between the thrombus formation and the presence of blood flow images in the left atria of 17 patients with mitral stenosis, and in the aneurysmal portions of the aorta or in the false lumens of aortic dissection of 18 patients. It was suggested that mural thrombi in such diseases were related to the relatively slow blood flow. Blood flow imaging easily distinguished stagnant blood flow from mural thrombi using non-gated short SE, end-systolic SE, and IR techniques. Thus, blood flow imaging using MRI should become an important means of evaluating the cardiovascular system. (author)

  20. Image flows and one-liner graphical image representation.

    Science.gov (United States)

    Makhervaks, Vadim; Barequet, Gill; Bruckstein, Alfred

    2002-10-01

    This paper introduces a novel graphical image representation consisting of a single curve-the one-liner. The first step of the algorithm involves the detection and ranking of image edges. A new edge exploration technique is used to perform both tasks simultaneously. This process is based on image flows. It uses a gradient vector field and a new operator to explore image edges. Estimation of the derivatives of the image is performed by using local Taylor expansions in conjunction with a weighted least-squares method. This process finds all the possible image edges without any pruning, and collects information that allows the edges found to be prioritized. This enables the most important edges to be selected to form a skeleton of the representation sought. The next step connects the selected edges into one continuous curve-the one-liner. It orders the selected edges and determines the curves connecting them. These two problems are solved separately. Since the abstract graph setting of the first problem is NP-complete, we reduce it to a variant of the traveling salesman problem and compute an approximate solution to it. We solve the second problem by using Dijkstra's shortest-path algorithm. The full software implementation for the entire one-liner determination process is available.

  1. Correlated diffusion imaging

    International Nuclear Information System (INIS)

    Wong, Alexander; Glaister, Jeffrey; Cameron, Andrew; Haider, Masoom

    2013-01-01

    Prostate cancer is one of the leading causes of cancer death in the male population. Fortunately, the prognosis is excellent if detected at an early stage. Hence, the detection and localization of prostate cancer is crucial for diagnosis, as well as treatment via targeted focal therapy. New imaging techniques can potentially be invaluable tools for improving prostate cancer detection and localization. In this study, we introduce a new form of diffusion magnetic resonance imaging called correlated diffusion imaging, where the tissue being imaged is characterized by the joint correlation of diffusion signal attenuation across multiple gradient pulse strengths and timings. By taking into account signal attenuation at different water diffusion motion sensitivities, correlated diffusion imaging can provide improved delineation between cancerous tissue and healthy tissue when compared to existing diffusion imaging modalities. Quantitative evaluation using receiver operating characteristic (ROC) curve analysis, tissue class separability analysis, and visual assessment by an expert radiologist were performed to study correlated diffusion imaging for the task of prostate cancer diagnosis. These results are compared with that obtained using T2-weighted imaging and standard diffusion imaging (via the apparent diffusion coefficient (ADC)). Experimental results suggest that correlated diffusion imaging provide improved delineation between healthy and cancerous tissue and may have potential as a diagnostic tool for cancer detection and localization in the prostate gland. A new form of diffusion magnetic resonance imaging called correlated diffusion imaging (CDI) was developed for the purpose of aiding radiologists in cancer detection and localization in the prostate gland. Preliminary results show CDI shows considerable promise as a diagnostic aid for radiologists in the detection and localization of prostate cancer

  2. Terahertz composite imaging method

    Institute of Scientific and Technical Information of China (English)

    QIAO Xiaoli; REN Jiaojiao; ZHANG Dandan; CAO Guohua; LI Lijuan; ZHANG Xinming

    2017-01-01

    In order to improve the imaging quality of terahertz(THz) spectroscopy, Terahertz Composite Imaging Method(TCIM) is proposed. The traditional methods of improving THz spectroscopy image quality are mainly from the aspects of de-noising and image enhancement. TCIM breaks through this limitation. A set of images, reconstructed in a single data collection, can be utilized to construct two kinds of composite images. One algorithm, called Function Superposition Imaging Algorithm(FSIA), is to construct a new gray image utilizing multiple gray images through a certain function. The features of the Region Of Interest (ROI) are more obvious after operating, and it has capability of merging ROIs in multiple images. The other, called Multi-characteristics Pseudo-color Imaging Algorithm(McPcIA), is to construct a pseudo-color image by combining multiple reconstructed gray images in a single data collection. The features of ROI are enhanced by color differences. Two algorithms can not only improve the contrast of ROIs, but also increase the amount of information resulting in analysis convenience. The experimental results show that TCIM is a simple and effective tool for THz spectroscopy image analysis.

  3. Image quality and dose differences caused by vendor-specific image processing of neonatal radiographs

    International Nuclear Information System (INIS)

    Sensakovic, William F.; O'Dell, M.C.; Letter, Haley; Kohler, Nathan; Rop, Baiywo; Cook, Jane; Logsdon, Gregory; Varich, Laura

    2016-01-01

    Image processing plays an important role in optimizing image quality and radiation dose in projection radiography. Unfortunately commercial algorithms are black boxes that are often left at or near vendor default settings rather than being optimized. We hypothesize that different commercial image-processing systems, when left at or near default settings, create significant differences in image quality. We further hypothesize that image-quality differences can be exploited to produce images of equivalent quality but lower radiation dose. We used a portable radiography system to acquire images on a neonatal chest phantom and recorded the entrance surface air kerma (ESAK). We applied two image-processing systems (Optima XR220amx, by GE Healthcare, Waukesha, WI; and MUSICA"2 by Agfa HealthCare, Mortsel, Belgium) to the images. Seven observers (attending pediatric radiologists and radiology residents) independently assessed image quality using two methods: rating and matching. Image-quality ratings were independently assessed by each observer on a 10-point scale. Matching consisted of each observer matching GE-processed images and Agfa-processed images with equivalent image quality. A total of 210 rating tasks and 42 matching tasks were performed and effective dose was estimated. Median Agfa-processed image-quality ratings were higher than GE-processed ratings. Non-diagnostic ratings were seen over a wider range of doses for GE-processed images than for Agfa-processed images. During matching tasks, observers matched image quality between GE-processed images and Agfa-processed images acquired at a lower effective dose (11 ± 9 μSv; P < 0.0001). Image-processing methods significantly impact perceived image quality. These image-quality differences can be exploited to alter protocols and produce images of equivalent image quality but lower doses. Those purchasing projection radiography systems or third-party image-processing software should be aware that image processing

  4. Cardiac hybrid imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gaemperli, Oliver [University Hospital Zurich, Cardiac Imaging, Zurich (Switzerland); University Hospital Zurich, Nuclear Cardiology, Cardiovascular Center, Zurich (Switzerland); Kaufmann, Philipp A. [University Hospital Zurich, Cardiac Imaging, Zurich (Switzerland); Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland)

    2014-05-15

    Hybrid cardiac single photon emission computed tomography (SPECT)/CT imaging allows combined assessment of anatomical and functional aspects of cardiac disease. In coronary artery disease (CAD), hybrid SPECT/CT imaging allows detection of coronary artery stenosis and myocardial perfusion abnormalities. The clinical value of hybrid imaging has been documented in several subsets of patients. In selected groups of patients, hybrid imaging improves the diagnostic accuracy to detect CAD compared to the single imaging techniques. Additionally, this approach facilitates functional interrogation of coronary stenoses and guidance with regard to revascularization procedures. Moreover, the anatomical information obtained from CT coronary angiography or coronary artery calcium scores (CACS) adds prognostic information over perfusion data from SPECT. The use of cardiac hybrid imaging has been favoured by the dissemination of dedicated hybrid systems and the release of dedicated image fusion software, which allow simple patient throughput for hybrid SPECT/CT studies. Further technological improvements such as more efficient detector technology to allow for low-radiation protocols, ultra-fast image acquisition and improved low-noise image reconstruction algorithms will be instrumental to further promote hybrid SPECT/CT in research and clinical practice. (orig.)

  5. Multiple Image Radiography With Diffraction Enhanced Imaging For Breast Specimen

    International Nuclear Information System (INIS)

    Oltulu, Oral; Zhong Zhong; Hasnah, Moumen; Chapman, Dean

    2007-01-01

    Biological samples are of great interest for many imaging techniques. The samples usually contain small structures and weak absorption properties. The combinations of weak signals with overlying structures make feature recognition difficult in many cases. In the x-ray regime, a relatively new imaging technique Diffraction Enhanced Imaging (DEI) has superior tissue contrast over conventional radiography and is proven to be very sensitive method. Multiple images taken by DEI are called Multiple Image Radiography (MIR). The purpose of this study is to validate the potential application of the method and to show that MIR-DEI method may give more information about the sample

  6. MR imaging in shoulder trauma. Value of STIR images

    International Nuclear Information System (INIS)

    Rand, T.; Trattnig, S.; Haller, J.; Imhof, H.; Nguyen, N.K.

    1998-01-01

    Purpose: To determine the adequacy of MR standard protocols by analyzing conventional T1- and T2-weighted SE sequences, and to evaluate the usefulness of additional fat-suppressed (STIR) images in shoulder trauma. Material and Methods: Paracoronal T1-weighted, T2-weighted SE, and STIR images were obtained on a 0.5 T superconductive system in 25 patients with shoulder trauma. In a separate evaluation of T1/T2 images and a combined evaluation of T1/T2 SE- and STIR images, we compared the number of patients with evidence of Hill-Sachs lesions, bone bruises, and/or rotator-cuff lesions. Results: Compared to the combined evaluation of T1/T2 and STIR images, the separate evaluation of T1/T2 SE images revealed identical results for rotator-cuff lesions and Hill-Sachs lesions, but different results for the bone bruises in the area of the major tubercle. Conclusion: Occult fractures of the major tubercle, indicated by areas of bone bruising, might be missed with MR using conventional SE images. We recommend the use of additional paracoronal fat-suppressed sequences in patients with clinically suspected lesions and equivocal findings on plain radiographs and on standard SE sequences. (orig.)

  7. Optical image encryption using multilevel Arnold transform and noninterferometric imaging

    Science.gov (United States)

    Chen, Wen; Chen, Xudong

    2011-11-01

    Information security has attracted much current attention due to the rapid development of modern technologies, such as computer and internet. We propose a novel method for optical image encryption using multilevel Arnold transform and rotatable-phase-mask noninterferometric imaging. An optical image encryption scheme is developed in the gyrator transform domain, and one phase-only mask (i.e., phase grating) is rotated and updated during image encryption. For the decryption, an iterative retrieval algorithm is proposed to extract high-quality plaintexts. Conventional encoding methods (such as digital holography) have been proven vulnerably to the attacks, and the proposed optical encoding scheme can effectively eliminate security deficiency and significantly enhance cryptosystem security. The proposed strategy based on the rotatable phase-only mask can provide a new alternative for data/image encryption in the noninterferometric imaging.

  8. Image forming apparatus

    DEFF Research Database (Denmark)

    2005-01-01

    (x, y) read out of the PALSLM is subjected to Fourier transform by a lens. A phase contrast filter gives a predetermined phase shift to only the zero-order light component of Fourier light image alpha f(x, y). The phase-shifted light image is subjected to inverse Fourier transform by a lens...... to project an output image O(x, y) to an output plane. A light image O'(x, y) branched by a beam sampler is picked up by a pickup device and an evaluation value calculating unit evaluates conformity between the image O(x, y) and the image G(x, y).; A control unit performs feedback control of optical...

  9. Targeted molecular imaging

    International Nuclear Information System (INIS)

    Kim, E. Edmund

    2003-01-01

    Molecular imaging aims to visualize the cellular and molecular processes occurring in living tissues, and for the imaging of specific molecules in vivo, the development of reporter probes and dedicated imaging equipment is most important. Reporter genes can be used to monitor the delivery and magnitude of therapeutic gene transfer, and the time variation involved. Imaging technologies such as micro-PET, SPECT, MRI and CT, as well as optical imaging systems, are able to non-invasively detect, measure, and report the simultaneous expression of multiple meaningful genes. It is believed that recent advances in reporter probes, imaging technologies and gene transfer strategies will enhance the effectiveness of gene therapy trials

  10. INTEGRATION OF IMAGE-DERIVED AND POS-DERIVED FEATURES FOR IMAGE BLUR DETECTION

    Directory of Open Access Journals (Sweden)

    T.-A. Teo

    2016-06-01

    Full Text Available The image quality plays an important role for Unmanned Aerial Vehicle (UAV’s applications. The small fixed wings UAV is suffering from the image blur due to the crosswind and the turbulence. Position and Orientation System (POS, which provides the position and orientation information, is installed onto an UAV to enable acquisition of UAV trajectory. It can be used to calculate the positional and angular velocities when the camera shutter is open. This study proposes a POS-assisted method to detect the blur image. The major steps include feature extraction, blur image detection and verification. In feature extraction, this study extracts different features from images and POS. The image-derived features include mean and standard deviation of image gradient. For POS-derived features, we modify the traditional degree-of-linear-blur (blinear method to degree-of-motion-blur (bmotion based on the collinear condition equations and POS parameters. Besides, POS parameters such as positional and angular velocities are also adopted as POS-derived features. In blur detection, this study uses Support Vector Machines (SVM classifier and extracted features (i.e. image information, POS data, blinear and bmotion to separate blur and sharp UAV images. The experiment utilizes SenseFly eBee UAV system. The number of image is 129. In blur image detection, we use the proposed degree-of-motion-blur and other image features to classify the blur image and sharp images. The classification result shows that the overall accuracy using image features is only 56%. The integration of image-derived and POS-derived features have improved the overall accuracy from 56% to 76% in blur detection. Besides, this study indicates that the performance of the proposed degree-of-motion-blur is better than the traditional degree-of-linear-blur.

  11. Molecular MR Imaging Probes

    OpenAIRE

    MAHMOOD, UMAR; JOSEPHSON, LEE

    2005-01-01

    Magnetic resonance imaging (MRI) has been successfully applied to many of the applications of molecular imaging. This review discusses by example some of the advances in areas such as multimodality MR-optical agents, receptor imaging, apoptosis imaging, angiogenesis imaging, noninvasive cell tracking, and imaging of MR marker genes.

  12. IMAGE ACQUISITION CONSTRAINTS FOR PANORAMIC FRAME CAMERA IMAGING

    Directory of Open Access Journals (Sweden)

    H. Kauhanen

    2012-07-01

    Full Text Available The paper describes an approach to quantify the amount of projective error produced by an offset of projection centres in a panoramic imaging workflow. We have limited this research to such panoramic workflows in which several sub-images using planar image sensor are taken and then stitched together as a large panoramic image mosaic. The aim is to simulate how large the offset can be before it introduces significant error to the dataset. The method uses geometrical analysis to calculate the error in various cases. Constraints for shooting distance, focal length and the depth of the area of interest are taken into account. Considering these constraints, it is possible to safely use even poorly calibrated panoramic camera rig with noticeable offset in projection centre locations. The aim is to create datasets suited for photogrammetric reconstruction. Similar constraints can be used also for finding recommended areas from the image planes for automatic feature matching and thus improve stitching of sub-images into full panoramic mosaics. The results are mainly designed to be used with long focal length cameras where the offset of projection centre of sub-images can seem to be significant but on the other hand the shooting distance is also long. We show that in such situations the error introduced by the offset of the projection centres results only in negligible error when stitching a metric panorama. Even if the main use of the results is with cameras of long focal length, they are feasible for all focal lengths.

  13. Blur Quantification of Medical Images: Dicom Media, Whole Slide Images, Generic Images and Videos

    Directory of Open Access Journals (Sweden)

    D. Ameisen

    2016-10-01

    Full Text Available Introduction/ Background We have designed a quality assurance tool to quantify blur by quantifying the sharpness of custom-sized tiles composing an image, generating global results, detailed exchangeable logs and sharpness-maps regardless of their dimensions, quantity or acquisition rate [1]. We have now integrated the programming libraries and the standalone program we built to existing workflows and software, in order to improve quality assurance procedures. Aims When integrated in an acquisition workflow, the ability to map the quality of local areas inside an image allows to re-acquire parts of the image that were not scanned properly, or discard and re-acquire images when the global results fall under the thresholds set by the users. When integrated in an image analysis software, the regions of interest can be automatically chosen or suggested to the user according to the quality-map of the image to analyze, reducing the amount of incoherent analysis results. When integrated as a library in an image management platform, or as a standalone program in a storage server, a systematic quality check can detect de-calibration of the acquisition software, failed acquisitions that may be automatically deleted and users can be notified to re-acquire the images when below their quality-thresholds profiles. A quantified quality score can be inserted in each image’s metadata for traceability purposes. When integrated as a library in a local or remote image viewer, the best quality tiles can be sent first to the viewer, and magnification levels can be dynamically resampled for a better render. Methods One notable implementation, using our Java library, is inside the FlexMIm project [2], which includes 27 pathology laboratories in the Paris area (coordinated by APHP, research laboratories from University Paris 6 Paris 7, as well as 3 companies: TRIBVN, PERTIMM and Orange. All Whole Slide Images are systematically analyzed and mapped as they enter the

  14. Dynamic flat panel detector versus image intensifier in cardiac imaging: dose and image quality

    Science.gov (United States)

    Vano, E.; Geiger, B.; Schreiner, A.; Back, C.; Beissel, J.

    2005-12-01

    The practical aspects of the dosimetric and imaging performance of a digital x-ray system for cardiology procedures were evaluated. The system was configured with an image intensifier (II) and later upgraded to a dynamic flat panel detector (FD). Entrance surface air kerma (ESAK) to phantoms of 16, 20, 24 and 28 cm of polymethyl methacrylate (PMMA) and the image quality of a test object were measured. Images were evaluated directly on the monitor and with numerical methods (noise and signal-to-noise ratio). Information contained in the DICOM header for dosimetry audit purposes was also tested. ESAK values per frame (or kerma rate) for the most commonly used cine and fluoroscopy modes for different PMMA thicknesses and for field sizes of 17 and 23 cm for II, and 20 and 25 cm for FD, produced similar results in the evaluated system with both technologies, ranging between 19 and 589 µGy/frame (cine) and 5 and 95 mGy min-1 (fluoroscopy). Image quality for these dose settings was better for the FD version. The 'study dosimetric report' is comprehensive, and its numerical content is sufficiently accurate. There is potential in the future to set those systems with dynamic FD to lower doses than are possible in the current II versions, especially for digital cine runs, or to benefit from improved image quality.

  15. Images of Usability

    DEFF Research Database (Denmark)

    Hertzum, Morten

    2010-01-01

    unless confronted with alternative images. This study delineates six images of usability: universal usability, situational usability, perceived usability, hedonic usability, organizational usability, and cultural usability. The different foci of the images provide opportunities for becoming sensitized...... assume different images of usability and a need for supplementary methods addressing the collaborative and long-term aspects of usability. Moreover, the images call for extending the scope of practical usability work to include the effects achieved by users during their use of systems for real work....

  16. Elemental abundance analyses with coadded Dominion Astrophysical Observatory spectrograms: Pt. 3

    International Nuclear Information System (INIS)

    Adelman, S.J.

    1988-01-01

    Elemental abundance analyses were performed for three superficially normal main-sequence stars θ Leonis (A2V), τ Herculus (B5IV) and ο Pegasi (AlIV). These studies used coadded spectrograms produced from at least 12 2.4 A mm -1 IIaO Dominion Astrophysical Observatory spectrograms and show a greater degree of internal consistency and smaller microturbulent velocities than previous studies of these stars which used lower signal-to-noise data. Many lines not previously seen were identified including some of new atomic species whose analysis provide a more complete picture of the elemental abundances. The identification and analysis of La II lines in ο Peg link this star more closely with the classical metallic-lined (Am) stars, although there are considerable differences in abundances. Some of θ Leo's elemental abundances, particularly those of vanadium, strontium, and zirconium, are significantly different from solar in confirmation of previous analyses. τ Her's elemental abundances are typically a factor of 2 less than solar. (author)

  17. Cine Club

    CERN Document Server

    Ciné Club

    2013-01-01

    Thursday 22 August 2013 at 20:00 CERN Council Chamber The Angels’ Share Directed by Ken Loach (UK, 2012) Original version English; french subtitles; 101 minute This bitter sweet comedy follows protagonist Robbie as he sneaks into the maternity hospital to visit his young girlfriend Leonie and hold his newborn son Luke for the first time. Overwhelmed by the moment, he swears that Luke will not have the same tragic life he has had. Escaping a prison sentence by the skin of his teeth, he's given one last chance...While serving a community service order, he meets Rhino, Albert and Mo who, like him, find it impossible to find work because of their criminal records. Little did Robbie imagine how turning to drink might change their lives - not cheap fortified wine, but the best malt whiskies in the world. Will it be 'slopping out' for the next twenty years, or a new future with 'Uisge Beatha' the 'Water of Life?' Only the angels know.... Th...

  18. Improvement of sidestream dark field imaging with an image acquisition stabilizer.

    Science.gov (United States)

    Balestra, Gianmarco M; Bezemer, Rick; Boerma, E Christiaan; Yong, Ze-Yie; Sjauw, Krishan D; Engstrom, Annemarie E; Koopmans, Matty; Ince, Can

    2010-07-13

    In the present study we developed, evaluated in volunteers, and clinically validated an image acquisition stabilizer (IAS) for Sidestream Dark Field (SDF) imaging. The IAS is a stainless steel sterilizable ring which fits around the SDF probe tip. The IAS creates adhesion to the imaged tissue by application of negative pressure. The effects of the IAS on the sublingual microcirculatory flow velocities, the force required to induce pressure artifacts (PA), the time to acquire a stable image, and the duration of stable imaging were assessed in healthy volunteers. To demonstrate the clinical applicability of the SDF setup in combination with the IAS, simultaneous bilateral sublingual imaging of the microcirculation were performed during a lung recruitment maneuver (LRM) in mechanically ventilated critically ill patients. One SDF device was operated handheld; the second was fitted with the IAS and held in position by a mechanic arm. Lateral drift, number of losses of image stability and duration of stable imaging of the two methods were compared. Five healthy volunteers were studied. The IAS did not affect microcirculatory flow velocities. A significantly greater force had to applied onto the tissue to induced PA with compared to without IAS (0.25 +/- 0.15 N without vs. 0.62 +/- 0.05 N with the IAS, p IAS ensured an increased duration of a stable image sequence (8 +/- 2 s without vs. 42 +/- 8 s with the IAS, p IAS. In eight mechanically ventilated patients undergoing a LRM the use of the IAS resulted in a significantly reduced image drifting and enabled the acquisition of significantly longer stable image sequences (24 +/- 5 s without vs. 67 +/- 14 s with the IAS, p = 0.006). The present study has validated the use of an IAS for improvement of SDF imaging by demonstrating that the IAS did not affect microcirculatory perfusion in the microscopic field of view. The IAS improved both axial and lateral SDF image stability and thereby increased the critical force required

  19. Deep architecture neural network-based real-time image processing for image-guided radiotherapy.

    Science.gov (United States)

    Mori, Shinichiro

    2017-08-01

    To develop real-time image processing for image-guided radiotherapy, we evaluated several neural network models for use with different imaging modalities, including X-ray fluoroscopic image denoising. Setup images of prostate cancer patients were acquired with two oblique X-ray fluoroscopic units. Two types of residual network were designed: a convolutional autoencoder (rCAE) and a convolutional neural network (rCNN). We changed the convolutional kernel size and number of convolutional layers for both networks, and the number of pooling and upsampling layers for rCAE. The ground-truth image was applied to the contrast-limited adaptive histogram equalization (CLAHE) method of image processing. Network models were trained to keep the quality of the output image close to that of the ground-truth image from the input image without image processing. For image denoising evaluation, noisy input images were used for the training. More than 6 convolutional layers with convolutional kernels >5×5 improved image quality. However, this did not allow real-time imaging. After applying a pair of pooling and upsampling layers to both networks, rCAEs with >3 convolutions each and rCNNs with >12 convolutions with a pair of pooling and upsampling layers achieved real-time processing at 30 frames per second (fps) with acceptable image quality. Use of our suggested network achieved real-time image processing for contrast enhancement and image denoising by the use of a conventional modern personal computer. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  20. Deblurring sequential ocular images from multi-spectral imaging (MSI) via mutual information.

    Science.gov (United States)

    Lian, Jian; Zheng, Yuanjie; Jiao, Wanzhen; Yan, Fang; Zhao, Bojun

    2018-06-01

    Multi-spectral imaging (MSI) produces a sequence of spectral images to capture the inner structure of different species, which was recently introduced into ocular disease diagnosis. However, the quality of MSI images can be significantly degraded by motion blur caused by the inevitable saccades and exposure time required for maintaining a sufficiently high signal-to-noise ratio. This degradation may confuse an ophthalmologist, reduce the examination quality, or defeat various image analysis algorithms. We propose an early work specially on deblurring sequential MSI images, which is distinguished from many of the current image deblurring techniques by resolving the blur kernel simultaneously for all the images in an MSI sequence. It is accomplished by incorporating several a priori constraints including the sharpness of the latent clear image, the spatial and temporal smoothness of the blur kernel and the similarity between temporally-neighboring images in MSI sequence. Specifically, we model the similarity between MSI images with mutual information considering the different wavelengths used for capturing different images in MSI sequence. The optimization of the proposed approach is based on a multi-scale framework and stepwise optimization strategy. Experimental results from 22 MSI sequences validate that our approach outperforms several state-of-the-art techniques in natural image deblurring.