WorldWideScience

Sample records for lensing experiment ogle

  1. OGLE-IV: Fourth Phase of the Optical Gravitational Lensing Experiment

    Science.gov (United States)

    Udalski, A.; Szymański, M. K.; Szymański, G.

    2015-03-01

    We present both the technical overview and main science drivers of the fourth phase of the Optical Gravitational Lensing Experiment (hereafter OGLE-IV). OGLE-IV is currently one of the largest sky variability surveys worldwide, targeting the densest stellar regions of the sky. The survey covers over 3000 square degrees in the sky and monitors regularly over a billion sources. The main targets include the inner Galactic Bulge and the Magellanic System. Their photometry spans the range of 12System and the Galactic disk. OGLE-IV provides the astronomical community with a number of real time services. The Early Warning System (EWS) contains information on two thousand gravitational microlensing events being discovered in real time annually, the OGLE Transient Detection System (OTDS) delivers over 200 supernovae a year. We also provide the real time photometry of unpredictable variables such as optical counterparts to the X-ray sources and R Coronae Borealis stars. Hundreds of thousands new variable stars have already been discovered and classified by the OGLE survey. The number of new detections will be at least doubled during the current OGLE-IV phase. The survey was designed and optimized primarily to conduct the second generation microlensing survey for exoplanets. It has already contributed significantly to the increase of the discovery rate of microlensing exoplanets and free-floating planets.

  2. REANALYSES OF ANOMALOUS GRAVITATIONAL MICROLENSING EVENTS IN THE OGLE-III EARLY WARNING SYSTEM DATABASE WITH COMBINED DATA

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, J.; Park, H.; Han, C. [Department of Physics, Institute for Astrophysics, Chungbuk National University, Cheongju 361-763 (Korea, Republic of); Gould, A.; Poleski, R. [Department of Astronomy, Ohio State University, 140 W. 18th Ave., Columbus, OH 43210 (United States); Udalski, A.; Szymański, M. K.; Pietrzyński, G.; Soszyński, I.; Ulaczyk, K.; Wyrzykowski, Ł. [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland); Abe, F.; Fukunaga, D.; Itow, Y. [Solar-Terrestrial Environment Laboratory, Nagoya University, Nagoya, 464-8601 (Japan); Bennett, D. P. [Department of Physics, University of Notre Dame, 225 Nieuwland Science Hall, Notre Dame, IN 46556-5670 (United States); Bond, I. A. [Institute of Information and Mathematical Sciences, Massey University, Private Bag 102-904, North Shore Mail Centre, Auckland (New Zealand); Botzler, C. S.; Freeman, M. [Department of Physics, University of Auckland, Private Bag 92-019, Auckland 1001 (New Zealand); Fukui, A. [Okayama Astrophysical Observatory, National Astronomical Observatory of Japan, Asakuchi, Okayama 719-0232 (Japan); Koshimoto, N. [Department of Earth and Space Science, Osaka University, Osaka 560-0043 (Japan); Collaboration: (The OGLE Collaboration); (The MOA Collaboration); (The PLANET Collaboration); (The μFUN Collaboration); (The RoboNet Collaboration); and others

    2015-05-01

    We reanalyze microlensing events in the published list of anomalous events that were observed from the Optical Gravitational Lensing Experiment (OGLE) lensing survey conducted during the 2004–2008 period. In order to check the existence of possible degenerate solutions and extract extra information, we conduct analyses based on combined data from other survey and follow-up observation and consider higher-order effects. Among the analyzed events, we present analyses of eight events for which either new solutions are identified or additional information is obtained. We find that the previous binary-source interpretations of five events are better interpreted by binary-lens models. These events include OGLE-2006-BLG-238, OGLE-2007-BLG-159, OGLE-2007-BLG-491, OGLE-2008-BLG-143, and OGLE-2008-BLG-210. With additional data covering caustic crossings, we detect finite-source effects for six events including OGLE-2006-BLG-215, OGLE-2006-BLG-238, OGLE-2006-BLG-450, OGLE-2008-BLG-143, OGLE-2008-BLG-210, and OGLE-2008-BLG-513. Among them, we are able to measure the Einstein radii of three events for which multi-band data are available. These events are OGLE-2006-BLG-238, OGLE-2008-BLG-210, and OGLE-2008-BLG-513. For OGLE-2008-BLG-143, we detect higher-order effects induced by the changes of the observer’s position caused by the orbital motion of the Earth around the Sun. In addition, we present degenerate solutions resulting from the known close/wide or ecliptic degeneracy. Finally, we note that the masses of the binary companions of the lenses of OGLE-2006-BLG-450 and OGLE-2008-BLG-210 are in the brown-dwarf regime.

  3. The Optical Gravitational Lensing Experiment

    Science.gov (United States)

    Udalski, A.; Szymanski, M.; Kaluzny, J.; Kubiak, M.; Mateo, Mario

    1992-01-01

    The technical features are described of the Optical Gravitational Lensing Experiment, which aims to detect a statistically significant number of microlensing events toward the Galactic bulge. Clusters of galaxies observed during the 1992 season are listed and discussed and the reduction methods are described. Future plans are addressed.

  4. Irradiation experiments of 3rd, 4th and 5th fuel assemblies by an in-pile gas loop, OGL-1

    International Nuclear Information System (INIS)

    Fukuda, Kousaku; Kobayashi, Fumiaki; Hayashi, Kimio; Minato, Kazuo; Kikuchi, Teruo; Adachi, Mamoru; Iwamoto, Kazumi; Ikawa, Katsuichi; Itami, Hiroharu.

    1986-07-01

    Three irradiation experiments for 3rd, 4th and 5th fuel assemblies which had been composed of VHTR reference coated particle fuels and graphite components were carried out by an in-pile gas loop, OGL-1 during 1979 and 1982. The main purposes of these experiments were to study on bowing of the fuel rod by irradiation for the 3rd fuel assembly, to study on fuel behavior under relatively low burnup irradiation for the 4th fuel assembly, and to study on fuel behavior up to full burnup of VHTR design for the 5th fuel assembly. For understanding in-pile fuel behavior, fractional releases of fission gases from each fuel assembly were estimated by measuring the fission gas concentrations in the primary loop of OGL-1. The post-irradiation examination (PIE) was carried out extensively on the fuel block, the fuel rods and the fuel compacts in Tokai Hot Laboratory. Also, made were the measurements of metallic fission product distributions in the fuel assemblies and the fuel rods. The results in these experiments were given as follows ; bowing of the fuel rod in the 3rd fuel assembly was 0.7 mm, but integrity of the rod was kept under irradiation. Fractional release of the fission gas from the 4th fuel assembly remained in the order of 10 -7 during irradiation, suggesting that the fuel performance was excellent. The fractional release from the 5th fuel assembly, on the other hand, was in the order of 10 -5 which was the same level in the VHTR design. (author)

  5. Des Ogle's old stump

    International Nuclear Information System (INIS)

    Jones, M.; Sutton, D.; Wallace, R.

    1998-01-01

    On 17 October 1997 Sylvia Bryan of RD4 Kaitaia wrote to 'Dear Somebody-Everybody' at the Anthropology Department, University of Auckland, urging further examination of an adzed stump found by Des Ogle during planting out of the Te Aupouri forest. The authors have since sought out relevant information and present it here for the interests of our readers. (author). 7 refs., 1 fig

  6. Faint-Source-Star Planetary Microlensing: The Discovery of the Cold Gas-Giant Planet OGLE-2014-BLG-0676Lb

    Science.gov (United States)

    Rattenbury, N. J.; Bennett, D. P.; Sumi, T.; Koshimoto, N.; Bond, I. A.; Udalski, A.; Shvartzvald, Y.; Maoz, D.; Jorgensen, U. G.; Barry, R.; hide

    2016-01-01

    We report the discovery of a planet OGLE-2014-BLG-0676Lb via gravitational microlensing. Observations for the lensing event were made by the following groups: Microlensing Observations in Astrophysics; Optical Gravitational Lensing Experiment; Wise Observatory; RoboNETLas Cumbres Observatory Global Telescope; Microlensing Network for the Detection of Small Terrestrial Exoplanets; and -FUN. All analyses of the light-curve data favoura lens system comprising a planetary mass orbiting a host star. The most-favoured binary lens model has a mass ratio between the two lens masses of (4.78 +/- 0.13) 10(exp -3). Subject to some important assumptions, a Bayesian probability density analysis suggests the lens system comprises a 3.09(+1.02/-1.12) MJ planet orbiting a 0.62(+0.20/-0.22) solar mass host star at a deprojected orbital separation of 4.40(+2.16/-1.46) au. The distance to the lens system is 2.22(+0.96/-0.83) kpc. Planet OGLE-2014-BLG-0676Lb provides additional data to the growing number of cool planets discover redusing gravitational microlensing against which planetary formation theories may be tested. Most of the light in the baseline of this event is expected to come from the lens and thus high-resolution imaging observations could confirm our planetary model interpretation.

  7. Jupiter Scleral Lenses: the UC Davis Eye Center experience.

    Science.gov (United States)

    Pecego, Mariana; Barnett, Melissa; Mannis, Mark J; Durbin-Johnson, Blythe

    2012-05-01

    The aim of this study was to evaluate both the indications for and results of fitting the Jupiter Scleral Lens in patients with corneal abnormalities. This was a retrospective case review of 63 patients (107 eyes) fitted with scleral lenses between October 2009 and March 2011 at the UC Davis Eye Center. Sixty-three percent of 107 eyes were in patients with keratoconus. Other conditions included high postkeratoplasty astigmatism and corneal scarring. The improvement in best-corrected visual acuity compared with previous contact lens or glasses correction was a mean gain of 3.5 Snellen lines (SD=2.6). Seventy-eight percent of patients found the scleral lenses to be comfortable or comfortable. Twenty-five eyes discontinued the wear after at least 3 months. Jupiter Scleral lenses are a good alternative for patients with corneal abnormalities and for those who failed other types of lens rehabilitation. Seventy-seven percent of eyes fit with Jupiter Scleral Lenses were still wearing after a follow-up of 3 months.

  8. The Use of Cylindrical Lenses in Easy Experiments for Physics Education and the Magic Arts

    Science.gov (United States)

    Bednarek, Stanislaw; Krysiak, Jerzy

    2011-01-01

    The purpose of this article is to present the properties of cylindrical lenses and provide some examples of their use in easy school physics experiments. Such experiments could be successfully conducted in the context of science education, in fun experiments that teach physics and in science fair projects, or used to entertain an audience by…

  9. OGLE-2016-BLG-0168 Binary Microlensing Event: Prediction and Confirmation of the Microlens Parallax Effect from Space-based Observations

    Energy Technology Data Exchange (ETDEWEB)

    Shin, I.-G.; Yee, J. C.; Jung, Y. K. [Smithsonian Astrophysical Observatory, 60 Garden Street, Cambridge, MA 02138 (United States); Udalski, A.; Skowron, J.; Mróz, P.; Soszyński, I.; Poleski, R.; Szymański, M. K.; Kozłowski, S.; Pietrukowicz, P.; Ulaczyk, K.; Pawlak, M. [Warsaw University Observatory, Al. Ujazdowskie 4,00-478 Warszawa (Poland); Novati, S. Calchi [IPAC, Mail Code 100-22, California Institute of Technology, 1200 E. California Boulevard, Pasadena, CA 91125 (United States); Han, C. [Department of Physics, Chungbuk National University, Cheongju 371-763 (Korea, Republic of); Albrow, M. D. [University of Canterbury, Department of Physics and Astronomy, Private Bag 4800, Christchurch 8020 (New Zealand); Gould, A. [Department of Astronomy, Ohio State University, 140 W. 18th Avenue, Columbus, OH 43210 (United States); Chung, S.-J.; Hwang, K.-H.; Ryu, Y.-H. [Korea Astronomy and Space Science Institute, 776 Daedeokdae-ro, Yuseong-Gu, Daejeon 34055 (Korea, Republic of); Collaboration: OGLE Collaboration; KMTNet Group; Spitzer Team; and others

    2017-11-01

    The microlens parallax is a crucial observable for conclusively identifying the nature of lens systems in microlensing events containing or composed of faint (even dark) astronomical objects such as planets, neutron stars, brown dwarfs, and black holes. With the commencement of a new era of microlensing in collaboration with space-based observations, the microlens parallax can be routinely measured. In addition, space-based observations can provide opportunities to verify the microlens parallax measured from ground-only observations and to find a unique solution to the lensing light-curve analysis. Furthermore, since most space-based observations cannot cover the full light curves of lensing events, it is also necessary to verify the reliability of the information extracted from fragmentary space-based light curves. We conduct a test based on the microlensing event OGLE-2016-BLG-0168, created by a binary lens system consisting of almost equal mass M-dwarf stars, to demonstrate that it is possible to verify the microlens parallax and to resolve degeneracies using the space-based light curve even though the observations are fragmentary. Since space-based observatories will frequently produce fragmentary light curves due to their short observing windows, the methodology of this test will be useful for next-generation microlensing experiments that combine space-based and ground-based collaboration.

  10. On the accuracy of mass measurement for microlensing black holes as seen by Gaia and OGLE

    Science.gov (United States)

    Rybicki, Krzysztof A.; Wyrzykowski, Łukasz; Klencki, Jakub; de Bruijne, Jos; Belczyński, Krzysztof; Chruślińska, Martyna

    2018-02-01

    We investigate the impact of combining Gaia astrometry from space with precise, high cadence OGLE photometry from the ground. For the archival event OGLE3-ULENS-PAR-02, which is likely a black hole, we simulate a realistic astrometric time-series of Gaia measurements and combine it with the real photometric data collected by the OGLE project. We predict that at the end of the nominal 5 years of the Gaia mission, for the events brighter than G ≈ 15.5 mag at the baseline, caused by objects heavier than 10 M⊙, it will be possible to unambiguously derive masses of the lenses, with accuracy between a few to 15 per cent. We find that fainter events (G stellar-origin black holes is ≈ 4 × 10^{-7} yr^{-1}, which implies, that after 5 years of Gaia operation and ≈5 × 106 bright sources in Gaia, it will be possible to identify few such events in the Gaia final catalogues.

  11. OGLE Collection of Star Clusters. New Objects in the Magellanic Bridge and the Outskirts of the Small Magellanic Cloud

    Science.gov (United States)

    Sitek, M.; Szymański, M. K.; Udalski, A.; Skowron, D. M.; Kostrzewa-Rutkowska, Z.; Skowron, J.; Karczmarek, P.; Cieślar, M.; Wyrzykowski, Ł.; Kozłowski, S.; Pietrukowicz, P.; Soszyński, I.; Mróz, P.; Pawlak, M.; Poleski, R.; Ulaczyk, K.

    2017-12-01

    The Magellanic System (MS) encompasses the nearest neighbors of the Milky Way, the Large (LMC) and Small (SMC) Magellanic Clouds, and the Magellanic Bridge (MBR). This system contains a diverse sample of star clusters. Their parameters, such as the spatial distribution, chemical composition and age distribution yield important information about the formation scenario of the whole Magellanic System. Using deep photometric maps compiled in the fourth phase of the Optical Gravitational Lensing Experiment (OGLE-IV) we present the most complete catalog of star clusters in the Magellanic System ever constructed from homogeneous, long time-scale photometric data. In this second paper of the series, we show the collection of star clusters found in the area of about 360 square degrees in the MBR and in the outer regions of the SMC. Our sample contains 198 visually identified star cluster candidates, 75 of which were not listed in any of the previously published catalogs. The new discoveries are mainly young small open clusters or clusters similar to associations.

  12. Spectral classification of nuclear transient OGLE18be as SN Ia at z=0.151

    Science.gov (United States)

    Gromadzki, M.; Wyrzykowski, L.; Bufano, F.; Berton, M.; Vogl, C.; Floers, A.; Taubenberger, S.; Anderson, J.; Galbany, L.; Schulze, S.; Yaron, O.; Manulis, I.; Inserra, C.; Kankare, E.; Maguire, K.; Smartt, S. J.; Young, D.; Smith, K. W.

    2018-02-01

    OGLE18be/SN2018be nuclear transient was discovered by the OGLE-IV Transient Search System (http://ogle.astrouw.edu.pl/ogle4/transients/ Wyrzykowski et al. 2014, Acta Astronomica 64, 197) on 2018-01-06.

  13. OGLE-2014-SN-073 as a fallback accretion powered supernova

    Science.gov (United States)

    Moriya, Takashi J.; Terreran, Giacomo; Blinnikov, Sergei I.

    2018-03-01

    We investigate the possibility that the energetic Type II supernova OGLE-2014-SN-073 is powered by a fallback accretion following the failed explosion of a massive star. Taking massive hydrogen-rich supernova progenitor models, we estimate the fallback accretion rate and calculate the light-curve evolution of supernovae powered by the fallback accretion. We find that such fallback accretion powered models can reproduce the overall observational properties of OGLE-2014-SN-073. It may imply that some failed explosions could be observed as energetic supernovae like OGLE-2014-SN-073 instead of faint supernovae as previously proposed.

  14. Stellar Variability Background in OGLE-I Microlensing Search

    Science.gov (United States)

    Wozniak, Przemyslaw; Szymanski, Michal

    1998-04-01

    We search OGLE-I photometric database for stars which, as defined by formal criteria adopted by OGLE-I microlensing search, showed variability during only one out of 3 or 4 observing seasons. The results include 17 previously reported microlensing events, 2 newly discovered candidate events and 15 intrinsically variable stars that have a potential of contaminating samples of microlensing events. Based on photometry obtained in 1992 and 1993 OGLE#10 was tentatively included in the list of microlensing candidates, however its light curve in 1994 and 1995 shows many characteristics of the variable stars found in our search, and most likely it is not a microlensing event. For all stars which passed our tests, we provide 44 times 44 arcsec (101 times 101 pixel) centered subframes from each OGLE-I frame in the I-band. It is the first time when images used to derive photometry of microlensing events are available in convenient format to astronomical community.

  15. Datamining in der OGLE-Datenbank - erste Versuche, erste Erfolge

    Science.gov (United States)

    Huemmerich, Stefan

    2012-01-01

    Three eclipsing binaries are presented, which were identified by investigation on OGLE-II I-band photmetry: OGLE-II CAR_SC3_64191 / 2MASS J11093656-6051588 (Type: EA,P=3.170361d); OGLE-II BUL_SC10_268243 (Type: EB, P=0.606285d); OGLE-II BUL_SC34_94176 / 2MASS J17575092-2911317 (Type: E/GS, P=16.427655d). Amplitude and period were derived by use of Period04. All objects were checked against the Strasbourg CDS Vizir service and the International Variable Star Index for pre-existence in variability catalogues.

  16. Identificação de variáveis cataclísmicas eruptivas na direção do bojo galáctico e Nuvens de Magalhães usando dados do OGLE

    Science.gov (United States)

    Cieslinski, D.; Diaz, M. P.; Mennickent, R.; Pietrzyski, G.

    2003-08-01

    Na década de 90 iniciaram-se vários programas para a pesquisa de matéria escura na Galáxia usando o efeito de microlentes gravitacionais. Entre os projetos mais bem conhecidos podemos mencionar o OGLE (Optical Gravitational Lensing Experiment) e o MACHO (MAssive Compact Halo Objects). A estratégia usada por eles consiste em fazer fotometria de banda larga (normalmente B, R e I) de um grande número de estrelas (dezenas de milhões) tão freqüentemente quanto possí vel e por longos perí odos de tempo (anos). Uma tal sistemática de observação, além de descobrir inúmeras lentes gravitacionais, é também muito apropriada para a descoberta de estrelas variáveis. De fato, inúmeras novas variáveis de vários tipos foram descobertas como subproduto. Exemplos podem ser encontrados nos endereços http://bulge.princeton.edu/~ogle/ e http://wwwmacho.mcmaster.ca/. As variáveis cataclí smicas eruptivas (novas clássicas, novas recorrentes e novas anãs) são objetos que apresentam variabilidade de grande amplitude com escalas de tempo de dias a centenas de dias e, por esta razão, devem ter sido detectadas em grande número nestes "surveys". Para testar esta possibilidade nós procuramos nos dados do OGLE por tais sistemas e o presente trabalho mostra os resultados desta pesquisa. Os objetos foram selecionados entre as variáveis detectadas usando a amplitude de variação de brilho como critério principal. Este critério forneceu 13756 objetos, sendo 2169 na direção da Grande Nuvem de Magalhães, 1162 na direção da Pequena Nuvem de Magalhães e o restante na direção do Bojo Galáctico. A análise foi feita inspecionando-se visualmente cada curva de luz por erupções com as características acima mencionadas. Os resultados obtidos podem ser sumarizados como: descoberta de duas novas clássicas e 33 novas anãs. Além disso, pode-se mencionar a identificação de candidatas a outros tipos de variáveis como: estrelas simbióticas, RV Tauri, R Coronae

  17. OGLE-ing the Magellanic system: stellar populations in the Magellanic Bridge

    Energy Technology Data Exchange (ETDEWEB)

    Skowron, D. M.; Jacyszyn, A. M.; Udalski, A.; Szymański, M. K.; Skowron, J.; Poleski, R.; Kozłowski, S.; Kubiak, M.; Pietrzyński, G.; Soszyński, I.; Mróz, P.; Pietrukowicz, P.; Ulaczyk, K.; Wyrzykowski, Ł., E-mail: dszczyg@astrouw.edu.pl [Warsaw University Astronomical Observatory, Aleje Ujazdowskie 4, 00-478 Warszawa (Poland)

    2014-11-10

    We report the discovery of a young stellar bridge that forms a continuous connection between the Magellanic Clouds. This finding is based on number density maps for stellar populations found in data gathered by OGLE-IV that fully cover over 270 deg{sup 2} of the sky in the Magellanic Bridge area. This is the most extensive optical survey of this region to date. We find that the young population is present mainly in the western half of the MBR, which, together with the newly discovered young population in the eastern Bridge, form a continuous stream of stars connecting both galaxies along δ ∼ –73.5 deg. The young population distribution is clumped, with one of the major densities close to the SMC and the other fairly isolated and located approximately mid-way between the Clouds, which we call the OGLE island. These overdensities are well matched by H I surface density contours, although the newly found young population in the eastern Bridge is offset by ∼2 deg north from the highest H I density contour. We observe a continuity of red clump stars between the Magellanic Clouds which represent an intermediate-age population. Red clump stars are present mainly in the southern and central parts of the Magellanic Bridge, below its gaseous part, and their presence is reflected by a strong deviation from the radial density profiles of the two galaxies. This may indicate either a tidal stream of stars, or that the stellar halos of the two galaxies overlap. On the other hand, we do not observe such an overlap within an intermediate-age population represented by the top of the red giant branch and the asymptotic giant branch stars. We also see only minor mixing of the old populations of the Clouds in the southern part of the Bridge, represented by the lowest part of the red giant branch.

  18. A NEW NONPLANETARY INTERPRETATION OF THE MICROLENSING EVENT OGLE-2013-BLG-0723

    Energy Technology Data Exchange (ETDEWEB)

    Han, Cheongho; Jung, Youn Kil [Department of Physics, Institute for Astrophysics, Chungbuk National University, 371-763 Cheongju (Korea, Republic of); Bennett, David P. [Code 667, NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Udalski, Andrzej [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland)

    2016-07-01

    Recently, the discovery of a Venus-mass planet orbiting a brown-dwarf host in a binary system was reported from the analysis of the microlensing event OGLE-2013-BLG-0723. We reanalyze the event considering the possibility of other interpretations. From this, we find a new solution where the lens is composed of two bodies, in contrast to the three-body solution of the previous analysis. The new solution better explains the observed light curve than the previous solution with Δ χ {sup 2} ∼ 202, suggesting that the new solution is a correct model for the event. From the estimation of the physical parameters based on the new interpretation, we find that the lens system is composed of two low-mass stars with ∼0.2 M {sub ⊙} and ∼0.1 M {sub ⊙} and located at a distance of ∼3 kpc. The fact that the physical parameters correspond to those of the most common lens population located at a distance with a large lensing probability further supports the likelihood of the new interpretation. Considering that two dramatically different solutions can approximately explain the observed light curve, the event suggests the need for carefully testing all possible lens-system geometries.

  19. Gravitational lensing

    CERN Document Server

    Dodelson, Scott

    2017-01-01

    Gravitational lensing is a consequence of general relativity, where the gravitational force due to a massive object bends the paths of light originating from distant objects lying behind it. Using very little general relativity and no higher level mathematics, this text presents the basics of gravitational lensing, focusing on the equations needed to understand the phenomena. It then applies them to a diverse set of topics, including multiply imaged objects, time delays, extrasolar planets, microlensing, cluster masses, galaxy shape measurements, cosmic shear, and lensing of the cosmic microwave background. This approach allows undergraduate students and others to get quickly up to speed on the basics and the important issues. The text will be especially relevant as large surveys such as LSST and Euclid begin to dominate the astronomical landscape. Designed for a one semester course, it is accessible to anyone with two years of undergraduate physics background.

  20. Acoustic lenses

    International Nuclear Information System (INIS)

    Kittmer, C.A.

    1983-03-01

    Acoustic lenses focus ultrasound to produce pencil-like beams with reduced near fields. When fitted to conventional (flat-faced) transducers, such lenses greatly improve the ability to detect and size defects. This paper describes a program developed to design acoustic lenses for use in immersion or contact inspection, using normal or angle beam mode with flat or curved targets. Lens surfaces are circular in geometry to facilitate machining. For normal beam inspection of flat plate, spherical or cylindrical lenses are used. For angle beam or curved surface inspections, a compound lens is required to correct for the extra induced aberration. Such a lens is aspherical with one radius of curvature in the plane of incidence, and a different radius of curvature in the plane perpendicular to the incident plane. The resultant beam profile (i.e., location of the acoustic focus, beam diameter, 6 dB working range) depends on the degree of focusing and the transducer used. The operating frequency and bandwidth can be affected by the instrumentation used. Theoretical and measured beam profiles are in good agreement. Various applications, from zone focusing used for defect sizing in thick plate, to line focusing for pipe weld inspection, are discussed

  1. OGLE ATLAS OF CLASSICAL NOVAE. II. MAGELLANIC CLOUDS

    Energy Technology Data Exchange (ETDEWEB)

    Mróz, P.; Udalski, A.; Poleski, R.; Soszyński, I.; Szymański, M. K.; Pietrzyński, G.; Wyrzykowski, Ł.; Ulaczyk, K.; Kozłowski, S.; Pietrukowicz, P.; Skowron, J., E-mail: pmroz@astrouw.edu.pl [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland)

    2016-01-15

    The population of classical novae in the Magellanic Clouds was poorly known because of a lack of systematic studies. There were some suggestions that nova rates per unit mass in the Magellanic Clouds were higher than in any other galaxy. Here, we present an analysis of data collected over 16 years by the OGLE survey with the aim of characterizing the nova population in the Clouds. We found 20 eruptions of novae, half of which are new discoveries. We robustly measure nova rates of 2.4 ± 0.8 yr{sup −1} (LMC) and 0.9 ± 0.4 yr{sup −1} (SMC) and confirm that the K-band luminosity-specific nova rates in both Clouds are 2–3 times higher than in other galaxies. This can be explained by the star formation history in the Magellanic Clouds, specifically the re-ignition of the star formation rate a few Gyr ago. We also present the discovery of the intriguing system OGLE-MBR133.25.1160, which mimics recurrent nova eruptions.

  2. Learning unit: Thin lenses

    Science.gov (United States)

    Nita, L.-S.

    2012-04-01

    Learning unit: Thin lenses "Why objects seen through lenses are sometimes upright and sometimes reversed" Nita Laura Simona National College of Arts and Crafts "Constantin Brancusi", Craiova, Romania 1. GEOMETRIC OPTICS. 13 hours Introduction (models, axioms, principles, conventions) 1. Thin lenses (Types of lenses. Defining elements. Path of light rays through lenses. Image formation. Required physical quantities. Lens formulas). 2. Lens systems (Non-collated lenses. Focalless systems). 3. Human eye (Functioning as an optical system. Sight defects and their corrections). 4. Optical instruments (Characteristics exemplified by a magnifying glass. Paths of light rays through a simplified photo camera. Path of light rays through a classical microscope) (Physics curriculum for the IXth grade/ 2011). This scenario exposes a learning unit based on experimental sequences (defining specific competencies), as a succession of lessons started by noticing a problem whose solution assumes the setup of an experiment under laboratory conditions. Progressive learning of theme objectives are realised with sequential experimental steps. The central cognitive process is the induction or the generalization (development of new knowledge based on observation of examples or counterexamples of the concept to be learnt). Pupil interest in theme objectives is triggered by problem-situations, for example: "In order to better see small objects I need a magnifying glass. But when using a magnifier, small object images are sometimes seen upright and sometimes seen reversed!" Along the way, pupils' reasoning will converge to the idea: "The image of an object through a lens depends on the relative distances among object, lens, and observer". Associated learning model: EXPERIMENT Specific competencies: derived from the experiment model, in agreement with the following learning unit steps I. Evoking - Anticipation: Size of the problem, formulation of hypotheses and planning of experiment. II

  3. OGLE-2015-BLG-0196: GROUND-BASED GRAVITATIONAL MICROLENS PARALLAX CONFIRMED BY SPACE-BASED OBSERVATION

    Energy Technology Data Exchange (ETDEWEB)

    Han, C. [Department of Physics, Chungbuk National University, Cheongju 361-763 (Korea, Republic of); Udalski, A.; Szymański, M. K.; Soszyński, I.; Skowron, J.; Mróz, P.; Poleski, R.; Pietrukowicz, P.; Kozłowski, S.; Ulaczyk, K.; Pawlak, M. [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland); Gould, A.; Zhu, Wei; Fausnaugh, M.; Gaudi, B. S. [Department of Astronomy, Ohio State University, 140 W. 18th Ave., Columbus, OH 43210 (United States); Yee, J. C. [Harvard-Smithsonian Center for Astrophysics, 60 Garden St., Cambridge, MA 02138 (United States); Beichman, C. [NASA Exoplanet Science Institute, MS 100-22, California Institute of Technology, Pasadena, CA 91125 (United States); Novati, S. Calchi [Dipartimento di Fisica “E. R. Caianiello,” Uńiversitá di Salerno, Via Giovanni Paolo II, I-84084 Fisciano (Italy); Carey, S. [Spitzer Science Center, MS 220-6, California Institute of Technology, Pasadena, CA (United States); Bryden, C. [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Dr., Pasadena, CA 91109 (United States); Collaboration: OGLE Collaboration; Spitzer Microlensing Team; and others

    2017-01-01

    In this paper, we present an analysis of the binary gravitational microlensing event OGLE-2015-BLG-0196. The event lasted for almost a year, and the light curve exhibited significant deviations from the lensing model based on the rectilinear lens-source relative motion, enabling us to measure the microlens parallax. The ground-based microlens parallax is confirmed by the data obtained from space-based microlens observations using the Spitzer telescope. By additionally measuring the angular Einstein radius from the analysis of the resolved caustic crossing, the physical parameters of the lens are determined up to the twofold degeneracy, u {sub 0} < 0 and u {sub 0} > 0, solutions caused by the well-known “ecliptic” degeneracy. It is found that the binary lens is composed of two M dwarf stars with similar masses, M {sub 1} = 0.38 ± 0.04 M {sub ⊙} (0.50 ± 0.05 M {sub ⊙}) and M {sub 2} = 0.38 ± 0.04 M {sub ⊙} (0.55 ± 0.06 M {sub ⊙}), and the distance to the lens is D {sub L} = 2.77 ± 0.23 kpc (3.30 ± 0.29 kpc). Here the physical parameters outside and inside the parentheses are for the u {sub 0} < 0 and u {sub 0} > 0 solutions, respectively.

  4. Design and performance tests of OGL-1 purification system

    International Nuclear Information System (INIS)

    Tanaka, Toshiyuki; Takahashi, Hidetake; Tone, Hirohito; Matsunaga, Sakuro

    1979-01-01

    The in-pile helium gas loop, OGL-1, was installed in JMTR at Oarai site of JAERI in 1976. Two types of the test fuel have been irradiated successfully. Low levels of both radioactivity and chemical contaminants show the integrity of VHTR test fuels and also no deterioration of graphite and other structural materials of high temperature components. The purification system consisting of a series of adsorbent beds works well to maintain the concentration of impurities in the coolant in the ranges of less than 10 vpm and to remove radioactive fission products from the main loop (10 -5 mu ci/ml at loop conditions). Plateout activities are low enough to assure the capability of access to the system for maintenance after reactor shutdown. (author)

  5. OGLE II Eclipsing Binaries In The LMC: Analysis With Class

    Science.gov (United States)

    Devinney, Edward J.; Prsa, A.; Guinan, E. F.; DeGeorge, M.

    2011-01-01

    The Eclipsing Binaries (EBs) via Artificial Intelligence (EBAI) Project is applying machine learning techniques to elucidate the nature of EBs. Previously, Prsa, et al. applied artificial neural networks (ANNs) trained on physically-realistic Wilson-Devinney models to solve the light curves of the 1882 detached EBs in the LMC discovered by the OGLE II Project (Wyrzykowski, et al.) fully automatically, bypassing the need for manually-derived starting solutions. A curious result is the non-monotonic distribution of the temperature ratio parameter T2/T1, featuring a subsidiary peak noted previously by Mazeh, et al. in an independent analysis using the EBOP EB solution code (Tamuz, et al.). To explore this and to gain a fuller understanding of the multivariate EBAI LMC observational plus solutions data, we have employed automatic clustering and advanced visualization (CAV) techniques. Clustering the OGLE II data aggregates objects that are similar with respect to many parameter dimensions. Measures of similarity for example, could include the multidimensional Euclidean Distance between data objects, although other measures may be appropriate. Applying clustering, we find good evidence that the T2/T1 subsidiary peak is due to evolved binaries, in support of Mazeh et al.'s speculation. Further, clustering suggests that the LMC detached EBs occupying the main sequence region belong to two distinct classes. Also identified as a separate cluster in the multivariate data are stars having a Period-I band relation. Derekas et al. had previously found a Period-K band relation for LMC EBs discovered by the MACHO Project (Alcock, et al.). We suggest such CAV techniques will prove increasingly useful for understanding the large, multivariate datasets increasingly being produced in astronomy. We are grateful for the support of this research from NSF/RUI Grant AST-05-75042 f.

  6. Electron Lenses for Experiments on Nonlinear Dynamics with Wide Stable Tune Spreads in the Fermilab Integrable Optics Test Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Stancari, G. [Fermilab; Carlson, K. [Fermilab; McGee, M. W. [Fermilab; Nobrega, L. E. [Fermilab; Romanov, A. L. [Fermilab; Ruan, J. [Fermilab; Valishev, A. [Fermilab; Noll, D. [Frankfurt U.

    2015-06-01

    Recent developments in the study of integrable Hamiltonian systems have led to nonlinear accelerator lattice designs with two transverse invariants. These lattices may drastically improve the performance of high-power machines, providing wide tune spreads and Landau damping to protect the beam from instabilities, while preserving dynamic aperture. To test the feasibility of these concepts, the Integrable Optics Test Accelerator (IOTA) is being designed and built at Fermilab. One way to obtain a nonlinear integrable lattice is by using the fields generated by a magnetically confined electron beam (electron lens) overlapping with the circulating beam. The parameters of the required device are similar to the ones of existing electron lenses. We present theory, numerical simulations, and first design studies of electron lenses for nonlinear integrable optics.

  7. Short-duration Lensing Events: Wide-orbit Planets? Free-floating Dwarfs? Or Hypervelocity Stellar Remnants?

    Science.gov (United States)

    Di Stefano, Rosanne; Patel, B.; Kallivayalil, N.; Primini, F. A.

    2009-01-01

    Ongoing microlensing observations by OGLE and MOA regularly detect and conduct high-cadence sampling of lensing events with Einstein diameter crossing times shorter than a few days. We show that many short-duration events are likely to have been caused by planet-mass or brown-dwarf lenses. Many of these low-mass lenses are located within a kpc. Information about some individual systems can be derived through a combination of lensing, radial velocity, and transit studies. The present discovery rate is high enough that the study of short-duration events could soon become the primary channel for planet detection via microlensing. We develop a protocol for observing and modeling these events, and apply it to archived data. A small number of short events may be caused by hypervelocity (v 10^3 km/s) masses located within a kpc.

  8. Optics Demonstrations Using Cylindrical Lenses

    Science.gov (United States)

    Ivanov, Dragia; Nikolov, Stefan

    2015-01-01

    In this paper we consider the main properties of cylindrical lenses and propose several demonstrational experiments that can be performed with them. Specifically we use simple glasses full of water to demonstrate some basic geometrical optics principles and phenomena. We also present some less standard experiments that can be performed with such…

  9. Relative radiosensitivity of rat lenses as a function of age

    International Nuclear Information System (INIS)

    Merriam, G.R. Jr.; Szechter, A.

    1975-01-01

    The effect of age on the development of radiation cataracts in rat lenses has been investigated using the Columbia--Sherman rat as an experiment model. A detailed pattern of age dependence was obtained at several different dose levels. In general at dose levels from 200 to 300 rads the lens changes occurred sooner and progressed faster in the adult lenses than in young lenses. In the dose range from 300 rads to 900 rads opacities developed sooner in the young lenses but progression was faster and severe opacities developed sooner in adult lenses. Above 900 rads opacities developed sooner and progressed faster in the young lenses. (U.S.)

  10. Magnetic electron lenses

    CERN Document Server

    1982-01-01

    No single volume has been entirely devoted to the properties of magnetic lenses, so far as I am aware, although of course all the numerous textbooks on electron optics devote space to them. The absence of such a volume, bringing together in­ formation about the theory and practical design of these lenses, is surprising, for their introduction some fifty years ago has created an entirely new family of commercial instruments, ranging from the now traditional transmission electron microscope, through the reflection and transmission scanning microscopes, to co­ lumns for micromachining and microlithography, not to mention the host of experi­ mental devices not available commercially. It therefore seemed useful to prepare an account of the various aspects of mag­ netic lens studies. These divide naturally into the five chapters of this book: the theoretical background, in which the optical behaviour is described and formu­ lae given for the various aberration coefficients; numerical methods for calculat­ ing...

  11. Gravitational lensing effect and polarization of the cosmic microwave background in the PLANCK Experiment and post-planckian projects; Effet de lentilles gravitationnelles et polarisation du fond diffus cosmologique dans le cadre de l'experience PLANCK et de projets post-planckiens

    Energy Technology Data Exchange (ETDEWEB)

    Perotto, Laurence [Universite Paris 7 - Denis Diderot, UFR de Physique, 75205 Paris Cedex 13 (France)

    2006-01-15

    This thesis is motivated by the upcoming high-resolution, high-sensitivity microwave background experiments, which should be sensitive to the CMB polarization and lensing. The first chapter provides a review of the CMB polarization with emphasis on future related experiments. The PLANCK experiment is described in a second chapter, where I develop a fast simulation code of PLANCK time-ordered data optimized to ease elaboration and test of data analysis methods. The two last chapters deal with gravitational lensing of the cosmic background radiation. First, I evaluate the capability of the upcoming experiments mentioned above to measure the power spectrum of Large Scale Structure by means of the extraction of weak lensing. Then I derive their sensitivity to the total neutrino mass, using the suppression of power due to free-streaming of massive neutrinos. Finally, I develop a method to estimate the foreground effects in the gravitational lensing extraction process. This method uses the best linear estimator available in the literature and is validated by numerical simulations that include non-Gaussian CMB lensed maps and extra-galactic radio sources maps. I find that sources emission reduces the sensitivity of future experiments to the weak lensing and leads to an overestimate of the convergence power spectrum. (author)

  12. Spitzer Observations of OGLE-2015-BLG-1212 Reveal a New Path toward Breaking Strong Microlens Degeneracies

    DEFF Research Database (Denmark)

    Bozza, V.; Shvartzvald, Y.; Udalski, A.

    2016-01-01

    Spitzer microlensing parallax observations of OGLE-2015-BLG-1212 decisively break a degeneracy between planetary and binary solutions that is somewhat ambiguous when only ground-based data are considered. Only eight viable models survive out of an initial set of 32 local minima in the parameter s...

  13. A giant planet beyond the snow line in microlensing event OGLE-2011-BLG-0251

    DEFF Research Database (Denmark)

    Kains, N.; Street, R.A.; Choi, J.-Y.

    2013-01-01

    Aims. We present the analysis of the gravitational microlensing event OGLE-2011-BLG-0251. This anomalous event was observed by several survey and follow-up collaborations conducting microlensing observations towards the Galactic bulge. Methods. Based on detailed modelling of the observed light cu...

  14. Arcs from gravitational lensing

    Science.gov (United States)

    Grossman, Scott A.; Narayan, Ramesh

    1988-01-01

    The proposal made by Paczynski (1987) that the arcs of blue light found recently in two cluster cores are gravitationally lensed elongated images of background galaxies is investigated. It is shown that lenses that are circularly symmetric in projection produce pairs of arcs, in conflict with the observations. However, more realistic asymmetric lenses produce single arcs, which can become as elongated as the observed ones whenever the background galaxy is located on or close to a cusp caustic. Detailed computer simulations of lensing by clusters using a reasonable model of the mass distribution are presented. Elongated and curved lensed images longer than 10 arcsec occur in 12 percent of the simulated clusters. It is concluded that the lensing hypothesis must be taken seriously.

  15. Weak lensing and cosmological investigation

    CERN Document Server

    Acquaviva, V

    2005-01-01

    In the last few years the scientific community has been dealing with the challenging issue of identifying the dark energy component. We regard weak gravitational lensing as a brand new, and extremely important, tool for cosmological investigation in this field. In fact, the features imprinted on the cosmic microwave background radiation by the lensing from the intervening distribution of matter represent a pretty unbiased estimator, and can thus be used for putting constraints on different dark energy models. This is true in particular for the magnetic-type B-modes of CMB polarization, whose unlensed spectrum at large multipoles (l approximately=1000) is very small even in presence of an amount of gravitational waves as large as currently allowed by the experiments: therefore, on these scales the lensing phenomenon is the only responsible for the observed power, and this signal turns out to be a faithful tracer of the dark energy dynamics. We first recall the formal apparatus of the weak lensing in extended t...

  16. Gravitational lensing and microlensing

    CERN Document Server

    Mollerach, Silvia

    2002-01-01

    This book provides a comprehensive and self-contained exposition of gravitational lensing phenomena. It presents the up-to-date status of gravitational lensing and microlensing, covering the cosmological applications of the observed lensing by galaxies, clusters and the large scale structures, as well as the microlensing searches in the Local Group and its applications to unveil the nature of the galactic dark matter, the search for planetary objects and the distribution of faint stars in our galaxy. Gravitational Lensing and Microlensing is pitched at the level of the graduate student interes

  17. Nanofocusing refractive X-ray lenses

    International Nuclear Information System (INIS)

    Boye, Pit

    2010-01-01

    This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is required. This is achieved in refractive lenses by moving to a compact lens design where several single lenses are stacked behind each other. The, so-called nanofocusing refractive lenses (NFLs) have a parabolic cylindrical shape with lateral structure sizes in the micrometer range. NFLs are produced by using micro-machining techniques. These micro-fabrication processes and technologies are introduced. The results of the optimization and the final fabrication process for silicon lenses are presented. Subsequently, two experiments that are exemplary for the use of NFLs, are introduced. The rst one employs a high-resolution scanning fluorescence mapping of a geological sample, and the second one is a coherent x-ray diffraction imaging (CXDI) experiment. CXDI is able to reconstruct the illuminated object from recorded coherent diffraction patterns. In a scanning mode, referred to as ptychography, this method is even able to reconstruct the illumination and the object simultaneously. Especially the reconstructed illumination and the possibility of computed propagation of the wave field along the

  18. Nanofocusing refractive X-ray lenses

    Energy Technology Data Exchange (ETDEWEB)

    Boye, Pit

    2010-02-05

    This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is required. This is achieved in refractive lenses by moving to a compact lens design where several single lenses are stacked behind each other. The, so-called nanofocusing refractive lenses (NFLs) have a parabolic cylindrical shape with lateral structure sizes in the micrometer range. NFLs are produced by using micro-machining techniques. These micro-fabrication processes and technologies are introduced. The results of the optimization and the final fabrication process for silicon lenses are presented. Subsequently, two experiments that are exemplary for the use of NFLs, are introduced. The rst one employs a high-resolution scanning fluorescence mapping of a geological sample, and the second one is a coherent x-ray diffraction imaging (CXDI) experiment. CXDI is able to reconstruct the illuminated object from recorded coherent diffraction patterns. In a scanning mode, referred to as ptychography, this method is even able to reconstruct the illumination and the object simultaneously. Especially the reconstructed illumination and the possibility of computed propagation of the wave field along the

  19. Learning through Different Lenses

    Science.gov (United States)

    Jeweler, Sue; Barnes-Robinson, Linda

    2015-01-01

    When parents and teachers help gifted kids use the metaphor "learning through different lenses," amazing things happen: Horizons open up. Ideas are focused. Thoughts are magnified and clarified. They see the big picture. Metaphoric thinking offers new and exciting ways to see the world. Viewing the world through different lenses provides…

  20. Inverting Gravitational Lenses

    Science.gov (United States)

    Newbury, P. R.; Spiteri, R. J.

    2002-02-01

    Gravitational lensing provides a powerful tool to study a number of fundamental questions in astrophysics. Fortuitously, one can begin to explore some non-trivial issues associated with this phenomenon without a lot of very sophisticated mathematics, making an elementary treatment of this topic tractable even to senior undergraduates. In this paper, we give a relatively self-contained outline of the basic concepts and mathematics behind gravitational lensing as a recent and exciting topic for courses in mathematical modeling or scientific computing. To this end, we have designed and made available some interactive software to aid in the simulation and inversion of gravitational lenses in a classroom setting.

  1. Stress-Detection Lenses

    Science.gov (United States)

    1996-01-01

    An Ames Research Center scientist invented an infrared lens used in sunglasses to filter out ultraviolet rays. This product finds its origins in research for military enemy detection. Through a Space Act Agreement, Optical Sales Corporation introduced the Hawkeye Lenses not only as sunglasses but as plant stress detection lenses. The lenses enhance the stressed part of the leaf, which has less chlorophyll than healthy leaves, through dyes that filter out certain wavelengths of light. Plant stress is visible earlier, at a stage when something can be done to save the plants.

  2. MASTER-ICATE constraints on the outburst time of OGLE-2012-NOVA-002

    Science.gov (United States)

    Levato, H.; Saffe, C.; Mallamaci, C.; Lopez, C.; Denisenko, F. Podest D.; Gorbovskoy, E.; Lipunov, V.; Balanutsa, P.; Tiurina, N.; Kornilov, V.; Belinski, A.; Shatskiy, N.; Chazov, V.; Kuznetsov, A.; Zimnukhov, D.; Krushinsky, V.; Zalozhnih, I.; Popov, A.; Bourdanov, A.; Punanova, A.; Ivanov, K.; Yazev, S.; Budnev, N.; Konstantinov, E.; Chuvalaev, O.; Poleshchuk, V.; Gress, O.; Parkhomenko, A.; Tlatov, A.; Dormidontov, D.; Senik, V.; Yurkov, V.; Sergienko, Y.; Varda, D.; Sinyakov, E.; Shumkov, V.; Shurpakov, S.; Podvorotny, P.

    2012-10-01

    MASTER-ICATE very wide field camera (72-mm f/1.2 lens + 11 Mpx CCD) located at Observatorio Astronomico Felix Aguilar (OAFA) near San Juan, Argentina, has observed the position of possible Nova OGLE-2012-NOVA-002 reported by L. Wyrzykowski et al. (ATel #4483) several times before 2012 May 20 and then again after 2012 July 03. MASTER-WFC is continuously imaging the areas of sky (24x16 sq. deg. field of view) with 5-sec unfiltered exposures.

  3. The First Simultaneous Microlensing Observations by Two Space Telescopes: Spitzer and Swift Reveal a Brown Dwarf in Event OGLE-2015-BLG-1319

    Science.gov (United States)

    Shvartzvald, Y.; Li, Z.; Udalski, A.; Gould, A.; Sumi, T.; Street, R. A.; Calchi Novati, S.; Hundertmark, M.; Bozza, V.; Beichman, C.; hide

    2016-01-01

    Simultaneous observations of microlensing events from multiple locations allow for the breaking of degeneracies between the physical properties of the lensing system, specifically by exploring different regions of the lens plane and by directly measuring the "microlens parallax". We report the discovery of a 30-65M J brown dwarf orbiting a K dwarf in the microlensing event OGLE-2015-BLG-1319. The system is located at a distance of approximately 5 kpc toward the Galactic Bulge. The event was observed by several ground-based groups as well as by Spitzer and Swift, allowing a measurement of the physical properties. However, the event is still subject to an eight-fold degeneracy, in particular the well-known close-wide degeneracy, and thus the projected separation between the two lens components is either approximately 0.25 au or approximately 45 au. This is the first microlensing event observed by Swift, with the UVOT camera. We study the region of microlensing parameter space to which Swift is sensitive, finding that though Swift could not measure the microlens parallax with respect to ground-based observations for this event, it can be important for other events. Specifically, it is important for detecting nearby brown dwarfs and free-floating planets in high magnification events.

  4. OGLE-2013-BLG-0102LA,B: MICROLENSING BINARY WITH COMPONENTS AT STAR/BROWN DWARF AND BROWN DWARF/PLANET BOUNDARIES

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Y. K.; Han, C. [Department of Physics, Chungbuk National University, Cheongju 371-763 (Korea, Republic of); Udalski, A.; Skowron, J.; Kozłowski, S.; Poleski, R.; Wyrzykowski, Ł.; Szymański, M. K.; Pietrzyński, G.; Soszyński, I.; Ulaczyk, K.; Pietrukowicz, P.; Mróz, P.; Kubiak, M. [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland); Sumi, T. [Department of Earth and Space Science, Osaka University, Osaka 560-0043 (Japan); Gould, A. [Department of Astronomy, Ohio State University, 140 West 18th Avenue, Columbus, OH 43210 (United States); Abe, F. [Solar-Terrestrial Environment Laboratory, Nagoya University, Nagoya 464-8601 (Japan); Bennett, D. P. [Department of Physics, University of Notre Dame, 225 Nieuwland Science Hall, Notre Dame, IN 46556-5670 (United States); Bond, I. A. [Institute of Information and Mathematical Sciences, Massey University, Private Bag 102-904, North Shore Mail Centre, Auckland (New Zealand); Botzler, C. S., E-mail: cheongho@astroph.chungbuk.ac.kr [Department of Physics, University of Auckland, Private Bag 92-019, Auckland 1001 (New Zealand); Collaboration: OGLE Collaboration; MOA Collaboration; μFUN Collaboration; and others

    2015-01-10

    We present an analysis of the gravitational microlensing event OGLE-2013-BLG-0102. The light curve of the event is characterized by a strong short-term anomaly superposed on a smoothly varying lensing curve with a moderate magnification A {sub max} ∼ 1.5. It is found that the event was produced by a binary lens with a mass ratio between the components of q = 0.13 and the anomaly was caused by the passage of the source trajectory over a caustic located away from the barycenter of the binary. Based on the analysis of the effects on the light curve due to the finite size of the source and the parallactic motion of the Earth, we determine the physical parameters of the lens system. The measured masses of the lens components are M {sub 1} = 0.096 ± 0.013 M {sub ☉} and M {sub 2} = 0.012 ± 0.002 M {sub ☉}, which correspond to near the hydrogen-burning and deuterium-burning mass limits, respectively. The distance to the lens is 3.04 ± 0.31 kpc and the projected separation between the lens components is 0.80 ± 0.08 AU.

  5. THE SECOND MULTIPLE-PLANET SYSTEM DISCOVERED BY MICROLENSING: OGLE-2012-BLG-0026Lb, c-A PAIR OF JOVIAN PLANETS BEYOND THE SNOW LINE

    Energy Technology Data Exchange (ETDEWEB)

    Han, C.; Choi, J.-Y. [Department of Physics, Institute for Astrophysics, Chungbuk National University, Cheongju 371-763 (Korea, Republic of); Udalski, A.; Szymanski, M. K.; Kubiak, M.; Soszynski, I.; Pietrzynski, G.; Poleski, R.; Ulaczyk, K.; Pietrukowicz, P.; Kozlowski, S.; Wyrzykowski, L. [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland); Yee, J. C.; Gould, A.; Skowron, J.; Batista, V. [Department of Astronomy, Ohio State University, 140 West 18th Avenue, Columbus, OH 43210 (United States); Christie, G. [Auckland Observatory, Auckland (New Zealand); Tan, T.-G. [Perth Exoplanet Survey Telescope, Perth (Australia); Almeida, L. A. [Instituto Nacional de Pesquisas Espaciais, Sao Jose dos Campos, SP (Brazil); Depoy, D. L. [Department of Physics, Texas A and M University, College Station, TX (United States); Collaboration: OGLE Collaboration; muFUN Collaboration; and others

    2013-01-10

    We report the discovery of a planetary system from observation of the high-magnification microlensing event OGLE-2012-BLG-0026. The lensing light curve exhibits a complex central perturbation with multiple features. We find that the perturbation was produced by two planets located near the Einstein ring of the planet host star. We identify four possible solutions resulting from the well-known close/wide degeneracy. By measuring both the lens parallax and the Einstein radius, we estimate the physical parameters of the planetary system. According to the best-fit model, the two planet masses are {approx}0.11 M{sub J} and 0.68 M{sub J} and they are orbiting a G-type main-sequence star with a mass {approx}0.82 M{sub Sun }. The projected separations of the individual planets are beyond the snow line in all four solutions, being {approx}3.8 AU and 4.6 AU in the best-fit solution. The deprojected separations are both individually larger and possibly reversed in order. This is the second multi-planet system with both planets beyond the snow line discovered by microlensing. This is the only such system (other than the solar system) with measured planet masses without sin i degeneracy. The planetary system is located at a distance 4.1 kpc from the Earth toward the Galactic center. It is very likely that extra light from stars other than the lensed star comes from the lens itself. If this is correct, it will be possible to obtain detailed information about the planet host star from follow-up observation.

  6. Gravitational lensing of quasars

    CERN Document Server

    Eigenbrod, Alexander

    2013-01-01

    The universe, in all its richness, diversity and complexity, is populated by a myriad of intriguing celestial objects. Among the most exotic of them are gravitationally lensed quasars. A quasar is an extremely bright nucleus of a galaxy, and when such an object is gravitationally lensed, multiple images of the quasar are produced – this phenomenon of cosmic mirage can provide invaluable insights on burning questions, such as the nature of dark matter and dark energy. After presenting the basics of modern cosmology, the book describes active galactic nuclei, the theory of gravitational lensing, and presents a particular numerical technique to improve the resolution of astronomical data. The book then enters the heart of the subject with the description of important applications of gravitational lensing of quasars, such as the measurement of the famous Hubble constant, the determination of the dark matter distribution in galaxies, and the observation of the mysterious inner parts of quasars with much higher r...

  7. Weakly oval electron lense

    International Nuclear Information System (INIS)

    Daumenov, T.D.; Alizarovskaya, I.M.; Khizirova, M.A.

    2001-01-01

    The method of the weakly oval electrical field getting generated by the axially-symmetrical field is shown. Such system may be designed with help of the cylindric form coaxial electrodes with the built-in quadrupole duplet. The singularity of the indicated weakly oval lense consists of that it provides the conducting both mechanical and electronic adjustment. Such lense can be useful for elimination of the near-axis astigmatism in the electron-optical system

  8. The Frequency of Snowline-Region Planets from Four Years of OGLE-MOA-Wise Second-Generation Microlensing

    Science.gov (United States)

    Shvartzvald, Y.; Maoz, D.; Udalski, A.; Sumi, T.; Friedmann, M.; Kaspi, S.; Poleski, R.; Szymanski, M. K.; Skowron, J.; Kozlowski, S.; hide

    2016-01-01

    We present a statistical analysis of the first four seasons from a second-generation microlensing survey for extrasolar planets, consisting of near-continuous time coverage of 8 deg to the 2nd power of the Galactic bulge by the Optical Gravitational Lens Experiment (OGLE), Microlensing Observations in Astrophysics (MOA), and Wise microlensing surveys. During this period, 224 microlensing events were observed by all three groups. Over 12% of the events showed a deviation from single-lens microlensing, and for approx. 1/3 of those the anomaly is likely caused by a planetary companion. For each of the 224 events, we have performed numerical ray-tracing simulations to calculate the detection efficiency of possible companions as a function of companion-to-host mass ratio and separation. Accounting for the detection efficiency, we find that 55 +34 -22%of microlensed stars host a snowline planet. Moreover, we find that Neptune-mass planets are approx.10 times more common than Jupiter-mass planets. The companion-to-host mass-ratio distribution shows a deficit at q approx. 10 (exp -2), separating the distribution into two companion populations, analogous to the stellar-companion and planet populations, seen in radial-velocity surveys around solar-like stars. Our survey, however, which probes mainly lower mass stars, suggests a minimum in the distribution in the super-Jupiter mass range, and a relatively high occurrence of brown-dwarf companions.

  9. Using place-based concepts, multicultural lenses, and hands-on experience to broaden participation in the sciences for native youth

    Science.gov (United States)

    Flick, K. C.; Keepseagle, L.

    2013-12-01

    . Through field trips to broaden perspective, self-directed action research projects, and formal and informal classroom settings, the SLC serves as a stepping stone for students to discover Science/Math/ Technology-related careers and interact with people and professionals of all ages who pursue these careers. SLC participation empowers young students so they may one day serve as leaders and roles models to positively influence their classmates, schools, and communities for future generations. Through this collaborative education design process we have used place-based concepts, multicultural lenses, and hands-on experiences to explore reciprocal learning relationships which broaden participation of native students in geosciences and geoscientists' participation in cultural teachings.

  10. OGLE-III MICROLENSING EVENTS AND THE STRUCTURE OF THE GALACTIC BULGE

    Energy Technology Data Exchange (ETDEWEB)

    Wyrzykowski, Łukasz; Rynkiewicz, Alicja E.; Skowron, Jan; Kozłowski, Szymon; Udalski, Andrzej; Szymański, Michał K.; Kubiak, Marcin; Soszyński, Igor; Pietrzyński, Grzegorz; Poleski, Radosław; Pietrukowicz, Paweł; Pawlak, Michał, E-mail: lw@astrouw.edu.pl [Warsaw University Astronomical Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland)

    2015-01-01

    We present and study the largest and most comprehensive catalog of microlensing events ever constructed. The sample of standard microlensing events comprises 3718 unique events from 2001-2009 with 1409 events that had not been detected before in real-time by the Early Warning System of the Optical Gravitational Lensing Experiment. The search pipeline uses machine learning algorithms to help find rare phenomena among 150 million objects and to derive the detection efficiency. Applications of the catalog can be numerous, from analyzing individual events to large statistical studies of the Galactic mass, kinematics distributions, and planetary abundances. We derive maps of the mean Einstein ring crossing time of events spanning 31 deg{sup 2} toward the Galactic center and compare the observed distributions with the most recent models. We find good agreement within the observed region and we see the signature of the tilt of the bar in the microlensing data. However, the asymmetry of the mean timescales seems to rise more steeply than predicted, indicating either a somewhat different orientation of the bar or a larger bar width. The map of events with sources in the Galactic bulge shows a dependence of the mean timescale on the Galactic latitude, signaling an increasing contribution from disk lenses closer to the plane relative to the height of the disk. Our data present a perfect set for comparing and enhancing new models of the central parts of the Milky Way and creating a three-dimensional picture of the Galaxy.

  11. CMB-lensing beyond the Born approximation

    International Nuclear Information System (INIS)

    Marozzi, Giovanni; Fanizza, Giuseppe; Durrer, Ruth; Dio, Enea Di

    2016-01-01

    We investigate the weak lensing corrections to the cosmic microwave background temperature anisotropies considering effects beyond the Born approximation. To this aim, we use the small deflection angle approximation, to connect the lensed and unlensed power spectra, via expressions for the deflection angles up to third order in the gravitational potential. While the small deflection angle approximation has the drawback to be reliable only for multipoles ℓ ∼< 2500, it allows us to consistently take into account the non-Gaussian nature of cosmological perturbation theory beyond the linear level. The contribution to the lensed temperature power spectrum coming from the non-Gaussian nature of the deflection angle at higher order is a new effect which has not been taken into account in the literature so far. It turns out to be the leading contribution among the post-Born lensing corrections. On the other hand, the effect is smaller than corrections coming from non-linearities in the matter power spectrum, and its imprint on CMB lensing is too small to be seen in present experiments.

  12. Plasma lenses for focusing relativistic electron beams

    International Nuclear Information System (INIS)

    Govil, R.; Wheeler, S.; Leemans, W.

    1997-01-01

    The next generation of colliders require tightly focused beams with high luminosity. To focus charged particle beams for such applications, a plasma focusing scheme has been proposed. Plasma lenses can be overdense (plasma density, n p much greater than electron beam density, n b ) or underdense (n p less than 2 n b ). In overdense lenses the space-charge force of the electron beam is canceled by the plasma and the remaining magnetic force causes the electron beam to self-pinch. The focusing gradient is nonlinear, resulting in spherical aberrations. In underdense lenses, the self-forces of the electron beam cancel, allowing the plasma ions to focus the beam. Although for a given beam density, a uniform underdense lens produces smaller focusing gradients than an overdense lens, it produces better beam quality since the focusing is done by plasma ions. The underdense lens can be improved by tapering the density of the plasma for optimal focusing. The underdense lens performance can be enhanced further by producing adiabatic plasma lenses to avoid the Oide limit on spot size due to synchrotron radiation by the electron beam. The plasma lens experiment at the Beam Test Facility (BTF) is designed to study the properties of plasma lenses in both overdense and underdense regimes. In particular, important issues such as electron beam matching, time response of the lens, lens aberrations and shot-to-shot reproducibility are being investigated

  13. Biocompatibility of Intraocular Lenses.

    Science.gov (United States)

    Özyol, Pelin; Özyol, Erhan; Karel, Fatih

    2017-08-01

    The performance of an intraocular lens is determined by several factors such as the surgical technique, surgical complications, intraocular lens biomaterial and design, and host reaction to the lens. The factor indicating the biocompatibility of an intraocular lens is the behavior of inflammatory and lens epithelial cells. Hence, the biocompatibility of intraocular lens materials is assessed in terms of uveal biocompatibility, based on the inflammatory foreign-body reaction of the eye against the implant, and in terms of capsular biocompatibility, determined by the relationship of the intraocular lens with residual lens epithelial cells within the capsular bag. Insufficient biocompatibility of intraocular lens materials may result in different clinical entities such as anterior capsule opacification, posterior capsule opacification, and lens epithelial cell ongrowth. Intraocular lenses are increasingly implanted much earlier in life in cases such as refractive lens exchange or pediatric intraocular lens implantation after congenital cataract surgery, and these lenses are expected to exhibit maximum performance for many decades. The materials used in intraocular lens manufacture should, therefore, ensure long-term uveal and capsular biocompatibility. In this article, we review the currently available materials used in the manufacture of intraocular lenses, especially with regard to their uveal and capsular biocompatibility, and discuss efforts to improve the biocompatibility of intraocular lenses.

  14. 3_gly_"&o {ft_y[:! *ogl9_ achieve

    African Journals Online (AJOL)

    until a terminal day-length of 14 hours at 2O weeks of age was achieved. The control treatment was a ..... this experiment than in the previous experiment (Mac- lachlan et aL, 1977) is in close agreement with ... Grouping of eggs accortling to mass os a percentage of the totol laid, to 28 weeks of age and production per pullet ...

  15. Analysis of irradiation temperature in fuel rods of OGL-1 fuel assembly

    International Nuclear Information System (INIS)

    Fukuda, Kousaku; Kobayashi, Fumiaki; Minato, Kazuo; Ikawa, Katsuichi; Iwamoto, Kazumi

    1984-10-01

    Irradiation temperature in the fuel rods of 5th OGL-1 fuel assembly was analysed by the system composed by STPDSP2 and TRUMP codes. As the measured input-data, following parameters were allowed for; circumferential heating distribution around the fuel rod, which was measured in the JMTR critical assembly, axial heating distribution through the fuel rod, ratio of peak heatings of three fuel rods, and pre- and post-irradiation outer radii of the fuel compacts and inner radii of the graphite sleeves, which had been measured in PIE of the 5th OGL-1 fuel assembly. In computation the axial distributions of helium coolant temperature through the fuel rod and the heating value of each fuel rod were, firstly, calculated as input data for TRUMP. The TRUMP calculation yielded the temperatures which were fitted in those measured by all of the thermo-couples installed in the fuel rods, by adjusting only the value of the surface heat transfer coefficient, and consequently, the temperatures in all portions of the fuel rod were obtained. The apparent heat transfer coefficient changed to 60% of the initial values in the middle period of irradiation. For this reduction it was deduced that shoot had covered the surface of the fuel rod during irradiation, which was confirmed in PIE. Beside it, several things were found in this analysis. (author)

  16. Planet observations of microlensing event OGLE-1999-BUL-23 : Limb-darkening measurement of the source star

    NARCIS (Netherlands)

    Albrow, MD; An, J; Beaulieu, JP; Caldwell, JAR; DePoy, DL; Dominik, M; Gaudi, BS; Gould, A; Greenhill, J; Hill, K; Kane, S; Martin, R; Menzies, J; Pogge, RW; Pollard, KR; Sackett, PD; Sahu, KC; Vermaak, P; Watson, R; Williams, A

    2001-01-01

    We present PLANET observations of OGLE-1999-BUL-23, a binary-lens microlensing event toward the Galactic bulge. PLANET observations in the I and V bands cover the event from just before the first caustic crossing until the end of the event. In particular, a densely sampled second caustic crossing

  17. OGLE-2005-BLG-071Lb, the Most Massive M-Dwarf Planetary Companion?

    Energy Technology Data Exchange (ETDEWEB)

    Dong, S; Gould, A; Udalski, A; Anderson, J; Christie, G W; Gaudi, B S; Jaroszynski, M; Kubiak, M; Szymanski, M K; Pietrzynski, G; Soszynski, I; Szewczyk, O; Ulaczyk, K; Wyrzykowski, L; DePoy, D L; Fox, D B; Gal-Yam, A; Han, C; Lepine, S; McCormick, J; Ofek, E; Park, B; Pogge, R W; Abe, F; Bennett, D P; Bond, I A; Britton, T R; Gilmore, A C; Hearnshaw, J B; Itow, Y; Kamiya, K; Kilmartin, P M; Korpela, A; Masuda, K; Matsubara, Y; Motomura, M; Muraki, Y; Nakamura, S; Ohnishi, K; Okada, C; Rattenbury, N; Saito, T; Sako, T; Sasaki, M; Sullivan, D; Sumi, T; Tristram, P J; Yanagisawa, T; Yock, P M; Yoshoika, T; Albrow, M D; Beaulieu, J P; Brillant, S; Calitz, H; Cassan, A; Cook, K H; Coutures, C; Dieters, S; Prester, D D; Donatowicz, J; Fouque, P; Greenhill, J; Hill, K; Hoffman, M; Horne, K; J?rgensen, U G; Kane, S; Kubas, D; Marquette, J B; Martin, R; Meintjes, P; Menzies, J; Pollard, K R; Sahu, K C; Vinter, C; Wambsganss, J; Williams, A; Bode, M; Bramich, D M; Burgdorf, M; Snodgrass, C; Steele, I; Doublier, V; Foelmi, C

    2008-04-18

    We combine all available information to constrain the nature of OGLE-2005-BLG-071Lb, the second planet discovered by microlensing and the first in a high-magnification event. These include photometric and astrometric measurements from Hubble Space Telescope, as well as constraints from higher-order effects extracted from the ground-based light curve, such as microlens parallax, planetary orbital motion and finite-source effects. Our primary analysis leads to the conclusion that the host of Jovian planet OGLE-2005-BLG-071Lb is a foreground M dwarf, with mass M = 0.46 {+-} 0.04M{sub {circle_dot}}, distance D{sub l} = 3.3 {+-} 0.4 kpc, and thick-disk kinematics {nu}{sub LSR} {approx} 103 km s{sup -1}. From the best-fit model, the planet has mass M{sub p} = 3.5 {+-} 0.3 M{sub Jupiter}, lies at a projected separation r{sub {perpendicular}} = 3.6 {+-} 0.2 AU from its host and has an equilibrium temperature of T {approx} 50 K, i.e., similar to Neptune. A degenerate model less favored by {Delta}{sub {chi}}{sup 2} {approx} 4 gives essentially the same planetary mass M{sub p} = 3.3 {+-} 0.3 M{sub Jupiter} with a smaller projected separation, r{sub {perpendicular}} = 2.1 {+-} 0.1 AU, and higher equilibrium temperature T {approx} 68 K. These results from the primary analysis suggest that OGLE-2005-BLG-071Lb is likely to be the most massive planet yet discovered that is hosted by an M dwarf. However, the formation of such high-mass planetary companions in the outer regions of M-dwarf planetary systems is predicted to be unlikely within the core-accretion scenario. There are a number of caveats to this analysis, but these could mostly be resolved by a single astrometric measurement a few years after the event.

  18. Additive manufacturing of tunable lenses

    Science.gov (United States)

    Schlichting, Katja; Novak, Tobias; Heinrich, Andreas

    2017-02-01

    Individual additive manufacturing of optical systems based on 3D Printing offers varied possibilities in design and usage. In addition to the additive manufacturing procedure, the usage of tunable lenses allows further advantages for intelligent optical systems. Our goal is to bring the advantages of additive manufacturing together with the huge potential of tunable lenses. We produced tunable lenses as a bundle without any further processing steps, like polishing. The lenses were designed and directly printed with a 3D Printer as a package. The design contains the membrane as an optical part as well as the mechanical parts of the lens, like the attachments for the sleeves which contain the oil. The dynamic optical lenses were filled with an oil. The focal length of the lenses changes due to a change of the radius of curvature. This change is caused by changing the pressure in the inside of the lens. In addition to that, we designed lenses with special structures to obtain different areas with an individual optical power. We want to discuss the huge potential of this technology for several applications. Further, an appropriate controlling system is needed. Wéll show the possibilities to control and regulate the optical power of the lenses. The lenses could be used for illumination tasks, and in the future, for individual measurement tasks. The main advantage is the individuality and the possibility to create an individual design which completely fulfills the requirements for any specific application.

  19. OGLE-2013-SN-079: A LONELY SUPERNOVA CONSISTENT WITH A HELIUM SHELL DETONATION

    Energy Technology Data Exchange (ETDEWEB)

    Inserra, C.; Sim, S. A.; Smartt, S. J.; Nicholl, M.; Jerkstrand, A.; Chen, T.-W. [Astrophysics Research Centre, School of Mathematics and Physics, Queens University Belfast, Belfast BT7 1NN (United Kingdom); Wyrzykowski, L. [University of Warsaw, Astronomical Observatory, Al. Ujazdowskie 400-478 Warszawa (Poland); Fraser, M.; Blagorodnova, N.; Campbell, H. [Institute of Astronomy, University of Cambridge, Madingley Road, CB3 0HA Cambridge (United Kingdom); Shen, K. J. [Department of Astronomy and Theoretical Astrophysics Center, University of California, Berkeley, CA 94720 (United States); Gal-Yam, A. [Benoziyo Center for Astrophysics, Weizmann Institute of Science, 76100 Rehovot (Israel); Howell, D. A.; Valenti, S. [Las Cumbres Observatory Global Telescope Network, 6740 Cortona Drive, Suite 102 Goleta, CA 93117 (United States); Maguire, K. [European Southern Observatory for Astronomical Research in the Southern Hemisphere (ESO), Karl-Schwarzschild-Str. 2, 85748 Garching b. Munchen (Germany); Mazzali, P.; Bersier, D. [Astrophysics Research Institute, Liverpool John Moores University, Liverpool (United Kingdom); Taubenberger, S.; Benitez-Herrera, S. [Max-Planck-Institut für Astrophysik, Karl-Schwarzschild-Str. 1, 85741 Garching (Germany); Elias-Rosa, N., E-mail: c.inserra@qub.ac.uk [INAF - Osservatorio Astronomico di Padova, Vicolo dell' Osservatorio 5, I-35122 Padova (Italy); and others

    2015-01-20

    We present observational data for a peculiar supernova discovered by the OGLE-IV survey and followed by the Public ESO Spectroscopic Survey for Transient Objects. The inferred redshift of z = 0.07 implies an absolute magnitude in the rest-frame I-band of M{sub I} ∼ –17.6 mag. This places it in the luminosity range between normal Type Ia SNe and novae. Optical and near infrared spectroscopy reveal mostly Ti and Ca lines, and an unusually red color arising from strong depression of flux at rest wavelengths <5000 Å. To date, this is the only reported SN showing Ti-dominated spectra. The data are broadly consistent with existing models for the pure detonation of a helium shell around a low-mass CO white dwarf and ''double-detonation'' models that include a secondary detonation of a CO core following a primary detonation in an overlying helium shell.

  20. RHIC electron lenses upgrades

    Energy Technology Data Exchange (ETDEWEB)

    Gu, X. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Altinbas, Z. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Bruno, D. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Binello, S. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Costanzo, M. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Drees, A. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Fischer, W. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Gassner, D. M. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Hock, J. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Hock, K. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Harvey, M. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Luo, Y. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Marusic, A. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Mi, C. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Mernick, K. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Minty, M. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Michnoff, R. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Miller, T. A. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Pikin, A. I. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Robert-Demolaize, G. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Samms, T. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Shrey, T. C. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Schoefer, V. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Tan, Y. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Than, R. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Thieberger, P. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; White, S. M. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.

    2015-05-03

    In the Relativistic Heavy Ion Collider (RHIC) 100 GeV polarized proton run in 2015, two electron lenses were used to partially compensate for the head-on beam-beam effect for the first time. Here, we describe the design of the current electron lens, detailing the hardware modifications made after the 2014 commissioning run with heavy ions. A new electron gun with 15-mm diameter cathode is characterized. The electron beam transverse profile was measured using a YAG screen and fitted with a Gaussian distribution. During operation, the overlap of the electron and proton beams was achieved using the electron backscattering detector in conjunction with an automated orbit control program.

  1. Ogle-2012-blg-0724lb: A Saturn Mass Planet Around an M-dwarf

    Science.gov (United States)

    Hirao, Y.; Sumi, T.; Bennett, D. P.; Bond, I. A.; Rattenbury, N.; Suzuki, D.; Koshimoto, N.; Abe, F.; Asakura, Y.; Bhattacharya, A.

    2016-01-01

    We report the discovery of a planet by the microlensing method, OGLE-2012-BLG-0724Lb. Although the duration of the planetary signal for this event was one of the shortest seen for a planetary event, the anomaly was well covered thanks to high-cadence observations taken by the survey groups OGLE and MOA. By analyzing the light curve, this planetary system is found to have a mass ratio q = (1.58 +/- 0.15) x 10(exp -3). By conducting a Bayesian analysis, we estimate that the host star is an M dwarf with a mass of M(sub L) = 0.29(+0.33/-0.16) solar mass located at D(sub L) = 6.7(+1.1/-1.2) kpc away from the Earth and the companion's mass is m(sub P) = 0.47(+0.54/-0.26) M(Jup). The projected planet- host separation is a falsum = 1.6(+0.4/-0.3) AU. Because the lens-source relative proper motion is relatively high, future highresolution images would detect the lens host star and determine the lens properties uniquely. This system is likely a Saturn-mass exoplanet around an M dwarf, and such systems are commonly detected by gravitational microlensing. This adds another example of a possible pileup of sub-Jupiters (0.2 less than m(sub P)/M(sub Jup) less than 1) in contrast to a lack of Jupiters (approximately 1-2 M(sub Jup)) around M dwarfs, supporting the prediction by core accretion models that Jupiter-mass or more massive planets are unlikely to form around M dwarfs.

  2. FORMING HABITABLE PLANETS AROUND DWARF STARS: APPLICATION TO OGLE-06-109L

    International Nuclear Information System (INIS)

    Wang Su; Zhou Jilin

    2011-01-01

    Dwarf stars are believed to have a small protostar disk where planets may grow up. During the planet formation stage, embryos undergoing type I migration are expected to be stalled at an inner edge of the magnetically inactive disk (a crit ∼ 0.2-0.3 AU). This mechanism makes the location around a crit a 'sweet spot' for forming planets. In dwarf stars with masses ∼0.5 M sun , a crit is roughly inside the habitable zone of the system. In this paper, we study the formation of habitable planets due to this mechanism using model system OGLE-06-109L, which has a 0.51 M sun dwarf star with two giant planets in 2.3 and 4.6 AU observed by microlensing. We model the embryos undergoing type I migration in the gas disk with a constant disk-accretion rate ( M-dot ). Giant planets in outside orbits affect the formation of habitable planets through secular perturbations at the early stage and secular resonance at the late stage. We find that the existence and the masses of the habitable planets in the OGLE-06-109L system depend on both M-dot and the speed of type I migration. If planets are formed earlier, so that M-dot is larger (∼10 -7 M sun yr -1 ), terrestrial planets cannot survive unless the type I migration rate is an order of magnitude less. If planets are formed later, so that M-dot is smaller (∼10 -8 M sun yr -1 ), single and high-mass terrestrial planets with high water contents (∼5%) will be formed by inward migration of outer planet cores. A slower-speed migration will result in several planets via collisions of embryos, and thus their water contents will be low (∼2%). Mean motion resonances or apsidal resonances among planets may be observed if multiple planets survive in the inner system.

  3. X-ray lenses with large aperture

    International Nuclear Information System (INIS)

    Simon, Markus

    2010-01-01

    Up to now, most X-ray imaging setups are based on absorption contrast imaging. There is a demand for focused X-rays in many X-ray analysis applications, either to increase the resolution of an imaging system, or, to reduce the time effort of an experiment through higher photon flux. For photon energies higher than 15 keV refractive X-ray optics are more efficient in comparison to non-refractive X-ray optics. The aim of this work was to develop X-ray lenses with large apertures and high transparency. By increasing the number of refracting surfaces while removing unnecessary lens material such lenses have been developed. Utilizing this approach the overall beam deflection angle is large with respect to the lens material it propagates through and so the transparency of the lens is increased. Within this work, X-ray lenses consisting of several thousands of prisms with an edge length in the range of micrometers have been developed and fabricated by deep X-ray lithography. Deep X-ray lithography enables high precision microstrucures with smooth sidewalls and large aspect ratios. The aperture of high-transparency X-ray lenses made this way is greater than 1 mm. They are suitable for photon energies in the range of 8 keV to 24 keV and offer a focal width of smaller than 10 μm at a transparency of around 40%. Furthermore, rolled X-ray lenses have been developed, that are made out of a microstructured polyimide film, which is cut according to the requirements regarding focal length and photon energy. The microstructured film is fabricated by molding, using an anisotropically etched silicon wafer as molding tool. Its mean roughness is in the range of nanometers. The film features prismatic structures, its surface topology is similar to an asparagus field. The measured diameter of the point focus was 18 μm to 31 μm, the calculated opticla efficiency was 37%. Future work will concentrate on increasing the aspect ratio of Prism Lenses and on increasing the rolling accuracy

  4. Halo-lensing or Self-lensing? Locating the MACHO Lenses

    Science.gov (United States)

    Nelson, C. A.; Cook, K. H.; Popowski, P.; Drake, A. J.; Marshall, S. L.; Griest, K.; Vandehei, T.; Alcock, C.; Allsman, R. A.; Axelrod, T. S.; Freeman, K. C.; Peterson, B. A.; Alves, D. R.; Becker, A. C.; Stubbs, C. W.; Tomaney, A. B.; Bennett, D. P.; Geha, M.; Lehner, M. J.; Minniti, D.; Pratt, M. R.; Quinn, P. J.; Sutherland, W.; Welch, D.; MACHO Collaboration

    2000-12-01

    There are two principle geometrical arrangements which may explain Large Magellanic Cloud (LMC) microlensing: a) halo-lensing, in which the lensed object is part of the Milky Way galactic halo and b) self-lensing, in which the lensed object is part of the LMC. Self-lensing in turn may be broken into two categories: LMC-LMC self-lensing, in which both the source and the lens reside in the LMC and background self-lensing, in which the lens is a star in the LMC and the source star is drawn from some population behind the LMC. Models suggest the contribution of LMC-LMC self-lensing is small, so the nature of LMC microlensing may be estimated from the location of the microlensing source stars. If the source stars are in the LMC then microlensing is dominated by halo-lensing; conversely if the source stars are located behind the LMC then microlensing is dominated by self-lensing. Since background populations reside behind the LMC, we expect them to be both redder and fainter then the average population of the LMC. We attempt to determine if the MACHO source stars come from such a background population by comparing the HST color-magnitude diagram (CMD) of source stars to the CMD of the average population of the LMC and looking for the effects of extra reddening and extinction. The microlensing source stars are identified by deriving accurate centroids in the ground-based MACHO images using difference image analysis (DIA) and then transforming the DIA coordinates to the HST frame. Preliminary results suggest that halo-lensing accounts for ≳ 40% of the observed microlensing results. Support provided by NASA, DOE, NSF and NPSC.

  5. Gravitational lenses and cosmological evolution

    International Nuclear Information System (INIS)

    Peacock, J.A.

    1982-01-01

    The effect of gravitational lensing on the apparent cosmological evolution of extragalactic radio sources is investigated. Models for a lens population consisting of galaxies and clusters of galaxies are constructed and used to calculate the distribution of amplification factors caused by lensing. Although many objects at high redshifts are predicted to have flux densities altered by 10 to 20 per cent relative to a homogeneous universe, flux conservation implies that de-amplification is as common as amplification. The effects on cosmological evolution as inferred from source counts and redshift data are thus relatively small; the slope of the counts is not large enough for intrinsically rare lensing events of high amplitude to corrupt observed samples. Lensing effects may be of greater importance for optically selected quasars, where lenses of mass as low as approximately 10 -4 solar mass can cause large amplifications. (author)

  6. Gravitational lenses and. cosmological evolution

    Science.gov (United States)

    Peacock, J. A.

    1982-06-01

    The effect of gravitational lensing on the apparent evolution of extragalactic radio sources is investigated. Models for a lens population consisting of galaxies and clusters of galaxies are constructed used to calculate the distribution of amplification factors caused by lensing ,. Although many objects at high redshifts are predicted to have flux densities altered by 10-20 per cent relative to a homogeneous universe, flux conservation implies that de-amplification is as common as amplification. The effect on cosmological evolution as inferred from source counts and redshift data are thus relatively small; the slope of the counts is not large enough for intrinsically rare lensing events of high amplitude to corrupt observed sample Lensing effects may be of greater importance for optically selected quasar where lenses of mass as low as ˜10-4 Msun can cause large amplifications.

  7. Subaru Weak Lensing Measurements of Four Strong Lensing Clusters: Are Lensing Clusters Over-Concentrated?

    Energy Technology Data Exchange (ETDEWEB)

    Oguri, Masamune; Hennawi, Joseph F.; Gladders, Michael D.; Dahle, Haakon; Natarajan, Priyamvada; Dalal, Neal; Koester, Benjamin P.; Sharon, Keren; Bayliss, Matthew

    2009-01-29

    We derive radial mass profiles of four strong lensing selected clusters which show prominent giant arcs (Abell 1703, SDSS J1446+3032, SDSS J1531+3414, and SDSS J2111-0115), by combining detailed strong lens modeling with weak lensing shear measured from deep Subaru Suprime-cam images. Weak lensing signals are detected at high significance for all four clusters, whose redshifts range from z = 0.28 to 0.64. We demonstrate that adding strong lensing information with known arc redshifts significantly improves constraints on the mass density profile, compared to those obtained from weak lensing alone. While the mass profiles are well fitted by the universal form predicted in N-body simulations of the {Lambda}-dominated cold dark matter model, all four clusters appear to be slightly more centrally concentrated (the concentration parameters c{sub vir} {approx} 8) than theoretical predictions, even after accounting for the bias toward higher concentrations inherent in lensing selected samples. Our results are consistent with previous studies which similarly detected a concentration excess, and increases the total number of clusters studied with the combined strong and weak lensing technique to ten. Combining our sample with previous work, we find that clusters with larger Einstein radii are more anomalously concentrated. We also present a detailed model of the lensing cluster Abell 1703 with constraints from multiple image families, and find the dark matter inner density profile to be cuspy with the slope consistent with -1, in agreement with expectations.

  8. Contact lenses for ophthalmic drug delivery.

    Science.gov (United States)

    Hui, Alex

    2017-09-01

    Contact lenses as a means to deliver pharmaceuticals to the eye have seen a significant increase in research interest in the past few years. This review will detail the in vitro experiments which have investigated use of these contact lenses in the context of the desired pharmacological treatment goals in the management of infectious, inflammatory, allergic and glaucomatous diseases of the eye. The techniques researchers have employed to modify and tailor drug release rates from these materials, including the use of vitamin E diffusion barriers, modified ionicity, molecular imprinting and incorporation of drug reservoirs, will be discussed, as well as their impact on drug release kinetics. Finally, the demonstration of the feasibility of these materials when applied in vivo in animal models as well as in humans with and without disease will be presented and their results discussed relating to their implications for the future of the field. © 2017 Optometry Australia.

  9. Pulsar lensing geometry

    Science.gov (United States)

    Liu, Siqi; Pen, Ue-Li; Macquart, J.-P.; Brisken, Walter; Deller, Adam

    2016-05-01

    We test the inclined sheet pulsar scintillation model (Pen & Levin) against archival very long baseline interferometry (VLBI) data on PSR 0834+06 and show that its scintillation properties can be precisely reproduced by a model in which refraction occurs on two distinct lens planes. These data strongly favour a model in which grazing-incidence refraction instead of diffraction off turbulent structures is the primary source of pulsar scattering. This model can reproduce the parameters of the observed diffractive scintillation with an accuracy at the percent level. Comparison with new VLBI proper motion results in a direct measure of the ionized interstellar medium (ISM) screen transverse velocity. The results are consistent with ISM velocities local to the PSR 0834+06 sight-line (through the Galaxy). The simple 1-D structure of the lenses opens up the possibility of using interstellar lenses as precision probes for pulsar lens mapping, precision transverse motions in the ISM, and new opportunities for removing scattering to improve pulsar timing. We describe the parameters and observables of this double screen system. While relative screen distances can in principle be accurately determined, a global conformal distance degeneracy exists that allows a rescaling of the absolute distance scale. For PSR B0834+06, we present VLBI astrometry results that provide (for the first time) a direct measurement of the distance of the pulsar. For most of the recycled millisecond pulsars that are the targets of precision timing observations, the targets where independent distance measurements are not available. The degeneracy presented in the lens modelling could be broken if the pulsar resides in a binary system.

  10. Simulation of the hydrodynamic conditions of the eye to better reproduce the drug release from hydrogel contact lenses: experiments and modeling.

    Science.gov (United States)

    Pimenta, A F R; Valente, A; Pereira, J M C; Pereira, J C F; Filipe, H P; Mata, J L G; Colaço, R; Saramago, B; Serro, A P

    2016-12-01

    Currently, most in vitro drug release studies for ophthalmic applications are carried out in static sink conditions. Although this procedure is simple and useful to make comparative studies, it does not describe adequately the drug release kinetics in the eye, considering the small tear volume and flow rates found in vivo. In this work, a microfluidic cell was designed and used to mimic the continuous, volumetric flow rate of tear fluid and its low volume. The suitable operation of the cell, in terms of uniformity and symmetry of flux, was proved using a numerical model based in the Navier-Stokes and continuity equations. The release profile of a model system (a hydroxyethyl methacrylate-based hydrogel (HEMA/PVP) for soft contact lenses (SCLs) loaded with diclofenac) obtained with the microfluidic cell was compared with that obtained in static conditions, showing that the kinetics of release in dynamic conditions is slower. The application of the numerical model demonstrated that the designed cell can be used to simulate the drug release in the whole range of the human eye tear film volume and allowed to estimate the drug concentration in the volume of liquid in direct contact with the hydrogel. The knowledge of this concentration, which is significantly different from that measured in the experimental tests during the first hours of release, is critical to predict the toxicity of the drug release system and its in vivo efficacy. In conclusion, the use of the microfluidic cell in conjunction with the numerical model shall be a valuable tool to design and optimize new therapeutic drug-loaded SCLs.

  11. Lensing bias to CMB polarization measurements of compensated isocurvature perturbations

    Science.gov (United States)

    Heinrich, Chen

    2018-01-01

    Compensated isocurvature perturbations (CIPs) are opposite spatial fluctuations in the baryon and dark matter (DM) densities. They arise in the curvaton model and some models of baryogenesis. While the gravitational effects of baryon fluctuations are compensated by those of DM, leaving no observable impacts on the cosmic microwave background (CMB) at first order, they modulate the sound horizon at recombination, thereby correlating CMB anisotropies at different multipoles. As a result, CIPs can be reconstructed using quadratic estimators similarly to CMB detection of gravitational lensing. Because of these similarities, however, the CIP estimators are biased with lensing contributions that must be subtracted. These lensing contributions for CMB polarization measurement of CIPs are found to roughly triple the noise power of the total CIP estimator on large scales. In addition, the cross power with temperature and E -mode polarization are contaminated by lensing-ISW (integrated Sachs-Wolfe) correlations and reionization-lensing correlations respectively. For a cosmic-variance-limited temperature and polarization experiment measuring out to multipoles lmax=2500 , the lensing noise raises the detection threshold by a factor of 1.5, leaving a 2.7 σ detection possible for the maximal CIP signal in the curvaton model.

  12. Electron lenses for the large hadron collider

    CERN Document Server

    Stancari†, G; Bruce, R; Redaelli, S; Rossi, A; Salvachua Ferrando, B

    2014-01-01

    Electron lenses are pulsed, magnetically confined electron beamswhose current-density profile is shaped to obtain the desired effect on the circulating beam. Electron lenses were used in the Fermilab Tevatron collider for bunch-bybunch compensation of long-range beam-beam tune shifts, for removal of uncaptured particles in the abort gap, for preliminary experiments on head-on beam-beamcompensation, and for the demonstration of halo scrapingwith hollow electron beams. Electron lenses for beam-beam compensation are being commissioned in RHIC at BNL. Within the US LHC Accelerator Research Program and the European HiLumi LHC Design Study, hollow electron beam collimation was studied as an option to complement the collimation system for the LHC upgrades. A conceptual design was recently completed, and the project is moving towards a technical design in 2014–2015 for construction in 2015–2017, if needed, after resuming LHC operations and re-assessing collimation needs and requirements at 6.5 TeV. Because of the...

  13. Cosmology with weak lensing surveys

    International Nuclear Information System (INIS)

    Munshi, Dipak; Valageas, Patrick; Waerbeke, Ludovic van; Heavens, Alan

    2008-01-01

    Weak gravitational lensing is responsible for the shearing and magnification of the images of high-redshift sources due to the presence of intervening matter. The distortions are due to fluctuations in the gravitational potential, and are directly related to the distribution of matter and to the geometry and dynamics of the Universe. As a consequence, weak gravitational lensing offers unique possibilities for probing the Dark Matter and Dark Energy in the Universe. In this review, we summarise the theoretical and observational state of the subject, focussing on the statistical aspects of weak lensing, and consider the prospects for weak lensing surveys in the future. Weak gravitational lensing surveys are complementary to both galaxy surveys and cosmic microwave background (CMB) observations as they probe the unbiased non-linear matter power spectrum at modest redshifts. Most of the cosmological parameters are accurately estimated from CMB and large-scale galaxy surveys, so the focus of attention is shifting to understanding the nature of Dark Matter and Dark Energy. On the theoretical side, recent advances in the use of 3D information of the sources from photometric redshifts promise greater statistical power, and these are further enhanced by the use of statistics beyond two-point quantities such as the power spectrum. The use of 3D information also alleviates difficulties arising from physical effects such as the intrinsic alignment of galaxies, which can mimic weak lensing to some extent. On the observational side, in the next few years weak lensing surveys such as CFHTLS, VST-KIDS and Pan-STARRS, and the planned Dark Energy Survey, will provide the first weak lensing surveys covering very large sky areas and depth. In the long run even more ambitious programmes such as DUNE, the Supernova Anisotropy Probe (SNAP) and Large-aperture Synoptic Survey Telescope (LSST) are planned. Weak lensing of diffuse components such as the CMB and 21 cm emission can also

  14. The measurement of intraocular pressure over positive soft contact lenses by rebound tonometry

    Directory of Open Access Journals (Sweden)

    Fabrizio Zeri

    2016-07-01

    Conclusions: Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result did not change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses.

  15. Use of Scleral Lenses and Miniscleral Lenses After Penetrating Keratoplasty.

    Science.gov (United States)

    Barnett, Melissa; Lien, Vivian; Li, Jennifer Y; Durbin-Johnson, Blythe; Mannis, Mark J

    2016-05-01

    To examine the clinical outcomes of scleral lenses for visual rehabilitation after penetrating keratoplasty (PK). A retrospective review was conducted for 34 patients (48 eyes) who had a history of prior PK and were fit with scleral lenses between October 2009 and December 2013 at the UC Davis Eye Center. The most common initial indication for PK was keratoconus in 27 eyes (56%). Thirty-three eyes (69%) had previously been fit with other types of contact lenses, with small-diameter rigid gas-permeable lenses being the most common. The improvement in best-corrected visual acuity with a scleral lens compared with prior spectacle refraction or other contact lens was a mean of two best-corrected visual acuity lines. Forty-four eyes (91.7%) achieved functional vision with best scleral lens-corrected visual acuities of 20/40 or better. Patients who continued wearing scleral lenses were significantly more likely to report "good" subjective vision compared with patients who abandoned scleral lens wear (P=0.009), although change in objective best-corrected visual acuity did not differ significantly. There were no cases of infectious keratitis. Six eyes (12.5%) developed graft rejection; 3 were able to resume scleral lens wear. Nineteen eyes (39.5%) discontinued scleral lens wear for various reasons, the most common reason for discontinuation of lens wear was difficulty with scleral lens insertion or removal (8 eyes, 42.1%). Scleral lenses are effective and safe in patients who have had PK. There was a mean gain in visual acuity, with the majority of patients achieving 20/40 vision or better. The patient's subjective perception of vision was a significant factor in determining whether scleral lens wear was continued or abandoned.

  16. Scleral lenses: a literature review.

    Science.gov (United States)

    Schornack, Muriel M

    2015-01-01

    To present a comprehensive review of current and historical literature on scleral lenses. A comprehensive search of several databases from each database's earliest inception to May 23, 2014 was conducted by an experienced librarian with input from the author to locate articles related to scleral lens design, fabrication, prescription, and management. A total of 899 references were identified, 184 of which were directly related to scleral lenses. References of interest were organized by date, topic, and study design. Most of articles published before 1983 presented lens design and fabrication techniques or indications for scleral lens therapy. Case reviews published after 1983 identified major indications for scleral lenses (corneal ectasia, ocular surface disease, and refractive error) and visual and functional outcomes of scleral lens wear. Statistically significant improvements in visual acuity, vision-related quality of life, and ocular surface integrity were reported. Reviews of ocular and systemic conditions suggested that comprehensive management strategies for these conditions could include scleral lenses. Early work investigating scleral lens fitting characteristics, optical qualities, and potential physiological impact on anterior ocular structures have been published in the past 5 years. Indications for scleral lens wear are well-established. Developing areas of research on the physiologic impact of scleral lens wear on the ocular surface, the use of technology to improve scleral lens vision and fit, and the impact of these devices on the quality of life should further enhance our understanding of scleral lenses in the future.

  17. Probing neutrino masses with CMB lensing extraction

    International Nuclear Information System (INIS)

    Lesgourgues, Julien; Perotto, Laurence; Pastor, Sergio; Piat, Michel

    2006-01-01

    We evaluate the ability of future cosmic microwave background (CMB) experiments to measure the power spectrum of large scale structure using quadratic estimators of the weak lensing deflection field. We calculate the sensitivity of upcoming CMB experiments such as BICEP, QUaD, BRAIN, ClOVER and Planck to the nonzero total neutrino mass M ν indicated by current neutrino oscillation data. We find that these experiments greatly benefit from lensing extraction techniques, improving their one-sigma sensitivity to M ν by a factor of order four. The combination of data from Planck and the SAMPAN mini-satellite project would lead to σ(M ν )∼0.1 eV, while a value as small as σ(M ν )∼0.035 eV is within the reach of a space mission based on bolometers with a passively cooled 3-4 m aperture telescope, representative of the most ambitious projects currently under investigation. We show that our results are robust not only considering possible difficulties in subtracting astrophysical foregrounds from the primary CMB signal but also when the minimal cosmological model (Λ Mixed Dark Matter) is generalized in order to include a possible scalar tilt running, a constant equation-of-state parameter for the dark energy and/or extra relativistic degrees of freedom

  18. Lentes de contato esclerais: experiência inicial no Setor de Lentes de Contato da Universidade Federal de São Paulo/Escola Paulista de Medicina Scleral contact lenses: first experience in the Contact Lens Sector of the Universidade Federal de São Paulo/Escola Paulista de Medicina

    Directory of Open Access Journals (Sweden)

    César Lipener

    2004-12-01

    Full Text Available OBJETIVO: Relatar a experiência inicial com o uso de lentes de contato esclerais rígidas. MÉTODOS: Estudo retrospectivo de 13 olhos de 7 pacientes usuários de lentes de contato esclerais, no Setor de Lentes de Contato da Universidade Federal de São Paulo/Escola Paulista de Medicina. Foram coletados os seguintes dados: idade, sexo, diagnóstico, acuidades visuais inicial e final, número de horas de uso diário, complicações, queixas e o tempo de seguimento dos pacientes. RESULTADOS: Foram estudados 13 olhos de 7 pacientes portadores de lentes esclerais rígidas, sendo 11 lentes de polimetilmetacrilato e 2 de material gás-permeável. Deste total, 6 pacientes eram portadores de ceratocone e 1 paciente havia sido submetido à ceratotomia radial. Em todos os olhos estudados houve melhora da acuidade visual. Os pacientes foram estudados em média por 8 meses. CONCLUSÃO: A utilização de lentes de contato esclerais pode ser uma opção na clínica de lentes de contato, propiciando melhora da acuidade visual em pacientes com ectasias corneanas ou submetidos à cirurgia refrativa, que aguardam transplante de córnea, como também, ser uma alternativa de tratamento clínico destes pacientes.PURPOSE: To describe initial experiences with patients wearing rigid escleral contact lenses. METHODS: Retrospective study of 13 eyes of 7 patients, 11 fitted with polymethylmethacrylate and two with rigid gas-permeable scleral contact lenses. Age, sex, diagnosis, initial and final visual acuity (VA, time of daily wear, complications and follow-up were recorded. RESULTS: Keratoconus was diagnosed in 6 patients, one was submitted to radial keratotomy. Mean follow-up lasted 8 months. Visual acuity of all eyes improves with scleral contact lenses. CONCLUSION: Visual acuity improvement observed in corneal ectasia and after radial keratotomy, in patients awaiting corneal graft, suggests that scleral contact lenses can be considered clinical treatment alternative.

  19. The First Circumbinary Planet Found by Microlensing: OGLE-2007-BLG-349L(AB)c

    Science.gov (United States)

    Bennett, D. P.; Rhie, S. H.; Udalski, A.; Gould, A.; Tsapras, Y.; Kubas, D.; Bond, I. A.; Greenhill, J.; Cassan, A.; Rattenbury, N. J.; hide

    2016-01-01

    We present the analysis of the first circumbinary planet microlensing event, OGLE-2007-BLG-349. This event has a strong planetary signal that is best fit with a mass ratio of q approx. = 3.4×10(exp -4), but there is an additional signal due to an additional lens mass, either another planet or another star. We find acceptable light-curve fits with two classes of models: two-planet models (with a single host star) and circumbinary planet models. The light curve also reveals a significant microlensing parallax effect, which constrains the mass of the lens system to be M(sub L) approx. = 0.7 Stellar Mass. Hubble Space Telescope (HST) images resolve the lens and source stars from their neighbors and indicate excess flux due to the star(s) in the lens system. This is consistent with the predicted flux from the circumbinary models, where the lens mass is shared between two stars, but there is not enough flux to be consistent with the two-planet, one-star models. So, only the circumbinary models are consistent with the HST data. They indicate a planet of mass m(sub c) = 80 +/- 13 Stellar Mass, orbiting a pair of M dwarfs with masses of M(sub A) = 0.41+/- 0.07 and M(sub B) = 0.30 +/- 0.07, which makes this the lowest-mass circumbinary planet system known. The ratio of the separation between the planet and the center of mass to the separation of the two stars is approx.40, so unlike most of the circumbinary planets found by Kepler, the planet does not orbit near the stability limit.

  20. Discovery of a Gas Giant Planet in Microlensing Event Ogle-2014-BLG-1760

    Science.gov (United States)

    Bhattacharya, A.; Bennett, D. P.; Bond, I. A.; Sumi, T.; Udalski, A.; Street, R.; Tsapras, Y.; Abe, F.; Freeman, M.; Fukui, A.

    2016-01-01

    We present the analysis of the planetary microlensing event OGLE-2014-BLG-1760, which shows a strong light-curve signal due to the presence of a Jupiter mass ratio planet. One unusual feature of this event is that the source star is quite blue, with V-I = 1.48 +/- 0.08. This is marginally consistent with a source star in the Galactic bulge, but it could possibly indicate a young source star on the far side of the disk. Assuming a bulge source, we perform a Bayesian analysis assuming a standard Galactic model, and this indicates that the planetary system resides in or near the Galactic bulge at D(sub L) = 6.9 +/- 1.1 kpc. It also indicates a host-star mass of M(sub *) = 0.51(sup + 0.44/sub -0.28) M(sub theta), a planet mass of m(sub p ) = 0.56(sup +0.34/sub -0.26) M(sub J), and a projected star-planet separation of a(perpendicular) = 1.75(sup +0.33/sub -0.34) au. The lens-source relative proper motion is micro(sub rel) = 6.5 +/- 1.1mas per yr. The lens (and stellar host star) is estimated to be very faint compared to the source star, so it is most likely that it can be detected only when the lens and source stars start to separate. Due to the relatively high relative proper motion, the lens and source will be resolved to about approximately 46 mas in 6-8 yr after the peak magnification. So, by 2020-2022, we can hope to detect the lens star with deep, high-resolution images.

  1. OGLE-2013-BLG-1761Lb: A Massive Planet around an MK Dwarf

    Science.gov (United States)

    Hirao, Y.; Udalski, A.; Sumi, T.; Bennett, D. P.; Koshimoto, N.; Bond, I. A.; Rattenbury, N. J.; Suzuki, D.; Abe, F.; Asakura, Y.; hide

    2017-01-01

    We report the discovery and the analysis of the planetary microlensing event, OGLE-2013-BLG-1761. There are some degenerate solutions in this event because the planetary anomaly is only sparsely sampled. However, the detailed light curve analysis ruled out all stellar binary models and shows the lens to be a planetary system. There is the so-called close wide degeneracy in the solutions with the planet host mass ratio of q approx.(7.0+/-2.0) x 10(exp -3) and q approx.(8.1+/-2.6) x 10(exp -3) with the projected separation in Einstein radius units of s = 0.95 (close) and s = 1.18(wide), respectively. The microlens parallax effect is not detected, but the finite source effect is detected. Our Bayesian analysis indicates that the lens system is located -D(sub L) = 6.9(+ 1.0 -1.2)kpc away from us and the host star is an M/K dwarf with amass of M(sub L) = 0.33(+ 0.32- 1.9)Stellar Mass orbited by a super-Jupiter mass planet with a mass of m(sub p) = 2.7(+ 2.5 - 1.5) M(sub Jup) at the projected separation of a(sub l) = 1.8(+ 0.5 -0.5)au. The preference of the large lens distance in the Bayesian analysis is due to the relatively large observed source star radius. The distance and other physical parameters may be constrained by the future high-resolution imaging by large ground telescopes or HST. If the estimated lens distance is correct, then this planet provides another sample for testing the claimed deficit of planets in the Galactic bulge.

  2. Aspheric lenses for terahertz imaging.

    Science.gov (United States)

    Lo, Yat Hei; Leonhardt, Rainer

    2008-09-29

    We present novel designs for aspheric lenses used in terahertz (THz) imaging. As different surfaces result in different beam shaping properties and in different losses from reflection and absorption, the resultant imaging resolution (i.e. the focal spot size) depends critically on the design approach. We evaluate the different lens designs using Kirchhoff's scalar diffraction theory, and test the predictions experimentally. We also show that our lenses can achieve sub-wavelength resolution. While our lens designs are tested with THz radiation, the design considerations are applicable also to other regions of the electro-magnetic spectrum.

  3. Gravitational lensing by exotic objects

    Science.gov (United States)

    Asada, Hideki

    2017-11-01

    This paper reviews a phenomenological approach to the gravitational lensing by exotic objects such as the Ellis wormhole lens, where the exotic lens objects may follow a non-standard form of the equation of state or may obey a modified gravity theory. A gravitational lens model is proposed in the inverse powers of the distance, such that the Schwarzschild lens and exotic lenses can be described in a unified manner as a one parameter family. As observational implications, the magnification, shear, photo-centroid motion and time delay in this lens model are discussed.

  4. Advances in scleral lenses for refractive surgery complications.

    Science.gov (United States)

    Parminder, Amy; Jacobs, Deborah S

    2015-07-01

    The last two decades have brought advances in materials and manufacturing of large diameter rigid gas-permeable contact lenses, and a greater appreciation of the role of scleral lenses for therapeutic indications. The purpose of this review is to provide an update on the use of rigid gas-permeable scleral lenses in the management of patients with complications after refractive surgery. There are recent reports on clinical experience with specific scleral lens designs from single institutions in cohorts that include patients who have undergone refractive surgery. Typically, these are patients with 'irregular corneas' after radial keratotomy or LASER assisted in-situ keratomileusis, but patients with keratectasia, dry eye syndrome, and corneal neuralgia are also reported. Visual outcomes and wearing success rates are high in these reports, although outcomes for refractive surgery patients are not reported separately. Clinicians who encounter patients with complications after corneal refractive surgery should be aware of advances in scleral lenses. Scleral lenses are an alternative to surgical intervention in patients who might otherwise be considered poor contact lens candidates.

  5. Gravitational Lensing of Supernova Neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Mena, Olga; /Fermilab /Rome U.; Mocioiu, Irina; /Penn State U.; Quigg, Chris; /Fermilab

    2006-10-01

    The black hole at the center of the galaxy is a powerful lens for supernova neutrinos. In the very special circumstance of a supernova near the extended line of sight from Earth to the galactic center, lensing could dramatically enhance the neutrino flux at Earth and stretch the neutrino pulse.

  6. Scientific visualization of gravitational lenses

    International Nuclear Information System (INIS)

    Magallon, M.

    1999-01-01

    Concepts related to gravitational lenses are discussed and applied to develop an interactive visualization tool that allow us to investigate them. Optimization strategies were performed to elaborate the tool. Some results obtained from the application of the tool are shown [es

  7. Polarization optics of GRIN lenses

    Science.gov (United States)

    Camacho, Javier; Tentori, Diana

    2001-01-01

    In this paper we show that the matrix representation for a linear retarder, given by Jones calculus, can be successfully applied to describe the birefringence properties of GRIN lenses for meridional rays. The usefulness of this description is experimentally verified by comparing the output pattern of a GRIN lens obtained in a linear polariscope with the predicted conoscopic pattern.

  8. Weak lensing and dark energy

    International Nuclear Information System (INIS)

    Huterer, Dragan

    2002-01-01

    We study the power of upcoming weak lensing surveys to probe dark energy. Dark energy modifies the distance-redshift relation as well as the matter power spectrum, both of which affect the weak lensing convergence power spectrum. Some dark-energy models predict additional clustering on very large scales, but this probably cannot be detected by weak lensing alone due to cosmic variance. With reasonable prior information on other cosmological parameters, we find that a survey covering 1000 sq deg down to a limiting magnitude of R=27 can impose constraints comparable to those expected from upcoming type Ia supernova and number-count surveys. This result, however, is contingent on the control of both observational and theoretical systematics. Concentrating on the latter, we find that the nonlinear power spectrum of matter perturbations and the redshift distribution of source galaxies both need to be determined accurately in order for weak lensing to achieve its full potential. Finally, we discuss the sensitivity of the three-point statistics to dark energy

  9. OGLE-2012-bLG-0950Lb: the First Planet Mass Measurement From Only Microlens Parallax and Lens Flux

    Science.gov (United States)

    Koshimoto, N.; Udalski, A.; Beaulieu, J. P.; Sumi, T.; Bennett, D. P.; Bond, I. A.; Rattenbury, N.; Fukui, A.; Bhattacharya, A.; Suzuki, D.

    2016-01-01

    We report the discovery of a microlensing planet OGLE-2012-BLG-0950Lb with a planet/host mass ratio Periapsis Approx. = 2 x10(exp. -4). A long term distortion detected in both MOA and OGLE light curve can be explained by themicrolens parallax due to the Earths orbital motion around the Sun. Although the finite source effect is not detected, we obtain the lens flux by the high resolution Keck AO observation. Combining the microlens parallax and the lens flux reveal the nature of the lens: a planet with mass of M(sub p) = 35(+17/-)M compared to Earth is orbiting around an M-dwarf with mass of M(sub host) = 0.56(+0.12/-0.16) M compared to the Sun with a planet-host projected separation of r1 = 2.7(+0.6/-0.7) au located at Luminosity Distance = 3.0(+0.8/-1.1) kpc from us. This is the first mass measurement from only microlens parallax and the lens flux without the finite source effect. In the coming space observation-era with Spitzer, K2, Euclid, and WFIRST, we expect many such events for which we will not be able to measure any finite source effect. This work demonstrates an ability of mass measurements in such events.

  10. SPITZER AS A MICROLENS PARALLAX SATELLITE: MASS MEASUREMENT FOR THE OGLE-2014-BLG-0124L PLANET AND ITS HOST STAR

    Energy Technology Data Exchange (ETDEWEB)

    Udalski, A.; Skowron, J.; Kozłowski, S.; Poleski, R.; Pietrukowicz, P.; Pietrzyński, G.; Szymański, M. K.; Mróz, P.; Soszyński, I.; Ulaczyk, K.; Wyrzykowski, Ł. [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland); Yee, J. C. [Harvard-Smithsonian Center for Astrophysics, 60 Garden St., Cambridge, MA 02138 (United States); Gould, A.; Zhu, W.; Pogge, R. W. [Department of Astronomy, Ohio State University, 140 W. 18th Ave., Columbus, OH 43210 (United States); Carey, S. [Spitzer Science Center, MS 220-6, California Institute of Technology, Pasadena, CA (United States); Han, C. [Department of Physics, Chungbuk National University, Cheongju 371-763 (Korea, Republic of); Calchi Novati, S. [NASA Exoplanet Science Institute, MS 100-22, California Institute of Technology, Pasadena, CA 91125 (United States)

    2015-02-01

    We combine Spitzer and ground-based observations to measure the microlens parallax vector π{sub E}, and thus the mass and distance of OGLE-2014-BLG-0124L, making it the first microlensing planetary system with a space-based parallax measurement. The planet and star have masses of m ∼ 0.5 M {sub jup} and M ∼ 0.7 M {sub ☉} and are separated by a ∼ 3.1 AU in projection. The main source of uncertainty in all of these numbers (approximately 30%, 30%, and 20%) is the relatively poor measurement of the Einstein radius θ{sub E}, rather than uncertainty in π{sub E}, which is measured with 2.5% precision. This compares to 22% based on OGLE data alone, implying that the Spitzer data provide not only a substantial improvement in the precision of the π{sub E} measurement, but also the first independent test of a ground-based π{sub E} measurement.

  11. EDITORIAL: Focus on Gravitational Lensing

    Science.gov (United States)

    Jain, Bhuvnesh

    2007-11-01

    Gravitational lensing emerged as an observational field following the 1979 discovery of a doubly imaged quasar lensed by a foreground galaxy. In the 1980s and '90s dozens of other multiply imaged systems were observed, as well as time delay measurements, weak and strong lensing by galaxies and galaxy clusters, and the discovery of microlensing in our galaxy. The rapid pace of advances has continued into the new century. Lensing is currently one of best techniques for finding and mapping dark matter over a wide range of scales, and also addresses broader cosmological questions such as understanding the nature of dark energy. This focus issue of New Journal of Physics presents a snapshot of current research in some of the exciting areas of lensing. It provides an occasion to look back at the advances of the last decade and ahead to the potential of the coming years. Just about a decade ago, microlensing was discovered through the magnification of stars in our galaxy by invisible objects with masses between that of Jupiter and a tenth the mass of the Sun. Thus a new component of the mass of our galaxy, dubbed MACHOs, was established (though a diffuse, cold dark matter-like component is still needed to make up most of the galaxy mass). More recently, microlensing led to another exciting discovery—of extra-solar planets with masses ranging from about five times that of Earth to that of Neptune. We can expect many more planets to be discovered through ongoing surveys. Microlensing is the best technique for finding Earth mass planets, though it is not as productive overall as other methods and does not allow for follow up observations. Beyond planet hunting, microlensing has enabled us to observe previously inaccessible systems, ranging from the surfaces of other stars to the accretion disks around the black holes powering distant quasars. Galaxies and galaxy clusters at cosmological distances can produce dramatic lensing effects: multiple images of background galaxies

  12. Creep-rupture properties of Hastellogy-X used as structural component in OGL-1

    International Nuclear Information System (INIS)

    Yokoi, S.; Monma, Y.; Fujimura, T.; Kikuyama, T.; Itami, K.

    Creep rupture tests were conducted on Hastelloy-X that is the material used for the inner wall tubes of the OGL-1 on the forged base material at 800, 900, and 1000 0 C and on the electron beam and TIG welded material at 900 and 1000 0 C, and the following results were obtained: (1) The stress-rupture time relationship for the forged base material was a linear relationship on a log-log plot for all three temperatures. (2) Rupture time of the electron beam weld material was of the same order as that of the base material at both 900 and 1000 0 C. (3) Rupture time of TIG weld material at 900 0 C was about the same as that of the base material, but this material ruptured at 1 / 2 - 1 / 3 the time of the base material at 1000 0 C. (4) Deformation and rupture modes of the base material were such that localized reduction in area was large to the low-temperature high-stress side, and the intragrain rupture was accompanied by cavity type microcracks. On the other hand, localized reduction in area was virtually nonexistent to the high-temperature low-stress side, and grain-boundary rupture due to wedge-shaped microcracks took place. (5) Rupture in TIG weld material at 1000 0 C took place through microcracks that formed along the Mo compounds precipitating continuously as large particles at the crystal grain boundaries of the welded metal. (6) The precipitate in the base material to the low temperature high stress side was Mo compounds distributed in uniform and minute manner within the grains, but it was a large Cr--Mo composite compound distributed along the grain boundary to the high temperature low stress side. (7) Large Mo compound precipitate deposited rapidly along the grain boundary of the welded metal of the TIG weld material at 1000 0 C as a result of which a Mo deficient layer was formed in the base about the precipitate, and this formation weakens the solid solution reinforcement of the base

  13. Daily disposable contact lenses versus spectacles in teenagers.

    Science.gov (United States)

    Plowright, Andrew J; Maldonado-Codina, Carole; Howarth, Gillian F; Kern, Jami; Morgan, Philip B

    2015-01-01

    To compare clinical and subjective quality-of-life (QoL) data for teenagers wearing daily disposable contact lenses or spectacles. This open-label study randomized subjects (aged 13 to 19 years) with no previous contact lens wear experience to nelfilcon A (DAILIES AquaComfort Plus) contact lenses or spectacles for 6 months. A full clinical workup, as well as subjective QoL measures using the Pediatric Refractive Error Profile and Quality of Life Impact of Refractive Correction questionnaires, was conducted at baseline and at week 4 and months 3 and 6, with an additional study visit at week 2 for subjects randomized to wear contact lenses. A total of 110 teenagers were enrolled in the study; 13 discontinued before study completion, 10 (17.5%) from the contact lens group and 3 (5.7%) from the spectacle group (p = 0.04). Visual acuity was good for both groups at all study visits. Biomicroscopy assessments were similar at baseline for both groups. Significant differences in Pediatric Refractive Error Profile responses were noted between vision correction groups across visits for appearance (p teenagers had a more positive attitude toward comfort, vision, and safety with contact lenses. No serious adverse events were reported during the study. The daily disposable lenses used in this study are suitable for vision correction for teenagers, offering improvements in QoL measures during the first month of wear, including appearance, satisfaction, activities, and peer perceptions, without negatively impacting vision or eye health. Teenagers were able to handle contact lenses with the same amount of confidence as spectacles.

  14. Gravitational lensing by rotating wormholes

    Science.gov (United States)

    Jusufi, Kimet; Ã-vgün, Ali

    2018-01-01

    In this paper the deflection angle of light by a rotating Teo wormhole spacetime is calculated in the weak limit approximation. We mainly focus on the weak deflection angle by revealing the gravitational lensing as a partially global topological effect. We apply the Gauss-Bonnet theorem (GBT) to the optical geometry osculating the Teo-Randers wormhole optical geometry to calculate the deflection angle. Furthermore we find the same result using the standard geodesic method. We have found that the deflection angle can be written as a sum of two terms, namely the first term is proportional to the throat of the wormhole and depends entirely on the geometry, while the second term is proportional to the spin angular momentum parameter of the wormhole. A direct observation using lensing can shed light and potentially test the nature of rotating wormholes by comparing with the black holes systems.

  15. A system of catoptric lenses

    International Nuclear Information System (INIS)

    McFarland, P.J.; Rambauske, W.R.

    1973-01-01

    Description is given of a system of catoptric lenses for combining energies provided by a certain number of sources, e.g. optical energies provided by a certain number of lasers. This system comprises sets of mirrors the reflecting surfaces of which have their focuses spaced from a common axis. The mirrors of all these sets are arranged on a common frame, which makes aperture-locking impossible. This can be applied to thermonuclear fusion [fr

  16. Glutathione preservation during storage of rat lenses in optisol-GS and castor oil.

    Science.gov (United States)

    Holm, Thomas; Brøgger-Jensen, Martin Rocho; Johnson, Leif; Kessel, Line

    2013-01-01

    Glutathione concentration in the lens decreases in aging and cataractous lenses, providing a marker for tissue condition. Experimental procedures requiring unfrozen lenses from donor banks rely on transportation in storage medium, affecting lens homeostasis and alterations in glutathione levels. The aim of the study was to examine the effects of Optisol-GS and castor oil on lens condition, determined from their ability to maintain glutathione concentrations. Rat lenses were stored in the two types of storage media at varying time intervals up to 3 days. Glutathione concentration was afterwards determined in an enzymatic detection assay, specific for both reduced and oxidized forms. Lenses removed immediately after death exhibited a glutathione concentration of 4.70±0.29 mM. In vitro stored lenses in Optisol-GS lost glutathione quickly, ending with a concentration of 0.60±0.34 mM after 3 days while castor oil stored lenses exhibited a slower decline and ended at 3 times the concentration. A group of lenses were additionally stored under post mortem conditions within the host for 6 hours before its removal. Total glutathione after 6 hours was similar to that of lenses removed immediately after death, but with altered GSH and GSSG concentrations. Subsequent storage of these lenses in media showed changes similar to those in the first series of experiments, albeit to a lesser degree. It was determined that storage in Optisol-GS resulted in a higher loss of glutathione than lenses stored in castor oil. Storage for more than 12 hours reduced glutathione to half its original concentration, and was considered unusable after 24 hours.

  17. Glutathione preservation during storage of rat lenses in optisol-GS and castor oil.

    Directory of Open Access Journals (Sweden)

    Thomas Holm

    Full Text Available BACKGROUND: Glutathione concentration in the lens decreases in aging and cataractous lenses, providing a marker for tissue condition. Experimental procedures requiring unfrozen lenses from donor banks rely on transportation in storage medium, affecting lens homeostasis and alterations in glutathione levels. The aim of the study was to examine the effects of Optisol-GS and castor oil on lens condition, determined from their ability to maintain glutathione concentrations. METHODOLOGY/PRINCIPAL FINDINGS: Rat lenses were stored in the two types of storage media at varying time intervals up to 3 days. Glutathione concentration was afterwards determined in an enzymatic detection assay, specific for both reduced and oxidized forms. Lenses removed immediately after death exhibited a glutathione concentration of 4.70±0.29 mM. In vitro stored lenses in Optisol-GS lost glutathione quickly, ending with a concentration of 0.60±0.34 mM after 3 days while castor oil stored lenses exhibited a slower decline and ended at 3 times the concentration. A group of lenses were additionally stored under post mortem conditions within the host for 6 hours before its removal. Total glutathione after 6 hours was similar to that of lenses removed immediately after death, but with altered GSH and GSSG concentrations. Subsequent storage of these lenses in media showed changes similar to those in the first series of experiments, albeit to a lesser degree. CONCLUSIONS/SIGNIFICANCE: It was determined that storage in Optisol-GS resulted in a higher loss of glutathione than lenses stored in castor oil. Storage for more than 12 hours reduced glutathione to half its original concentration, and was considered unusable after 24 hours.

  18. 30 CFR 18.30 - Windows and lenses.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Windows and lenses. 18.30 Section 18.30 Mineral... § 18.30 Windows and lenses. (a) MSHA may waive testing of materials for windows or lenses except headlight lenses. When tested, material for windows or lenses shall meet the test requirements prescribed in...

  19. Planck 2015 results. XV. Gravitational lensing

    CERN Document Server

    Ade, P.A.R.; Arnaud, M.; Ashdown, M.; Aumont, J.; Baccigalupi, C.; Banday, A.J.; Barreiro, R.B.; Bartlett, J.G.; Bartolo, N.; Basak, S.; Battaner, E.; Benabed, K.; Benoît, A.; Benoit-Lévy, A.; Bernard, J.-P.; Bersanelli, M.; Bielewicz, P.; Bock, J.J.; Bonaldi, A.; Bonavera, L.; Bond, J.R.; Borrill, J.; Bouchet, F.R.; Boulanger, F.; Bucher, M.; Burigana, C.; Butler, R.C.; Calabrese, E.; Cardoso, J.-F.; Catalano, A.; Challinor, A.; Chamballu, A.; Chiang, H.C.; Christensen, P.R.; Church, S.; Clements, D.L.; Colombi, S.; Colombo, L.P.L.; Combet, C.; Couchot, F.; Coulais, A.; Crill, B.P.; Curto, A.; Cuttaia, F.; Danese, L.; Davies, R.D.; Davis, R.J.; de Bernardis, P.; de Rosa, A.; de Zotti, G.; Delabrouille, J.; Désert, F.-X.; Diego, J.M.; Dole, H.; Donzelli, S.; Doré, O.; Douspis, M.; Ducout, A.; Dunkley, J.; Dupac, X.; Efstathiou, G.; Elsner, F.; Enßlin, T.A.; Eriksen, H.K.; Fergusson, J.; Finelli, F.; Forni, O.; Frailis, M.; Fraisse, A.A.; Franceschi, E.; Frejsel, A.; Galeotta, S.; Galli, S.; Ganga, K.; Giard, M.; Giraud-Héraud, Y.; Gjerløw, E.; González-Nuevo, J.; Górski, K.M.; Gratton, S.; Gregorio, A.; Gruppuso, A.; Gudmundsson, J.E.; Hansen, F.K.; Hanson, D.; Harrison, D.L.; Henrot-Versillé, S.; Hernández-Monteagudo, C.; Herranz, D.; Hildebrandt, S.R.; Hivon, E.; Hobson, M.; Holmes, W.A.; Hornstrup, A.; Hovest, W.; Huffenberger, K.M.; Hurier, G.; Jaffe, A.H.; Jaffe, T.R.; Jones, W.C.; Juvela, M.; Keihänen, E.; Keskitalo, R.; Kisner, T.S.; Kneissl, R.; Knoche, J.; Kunz, M.; Kurki-Suonio, H.; Lagache, G.; Lähteenmäki, A.; Lamarre, J.-M.; Lasenby, A.; Lattanzi, M.; Lawrence, C.R.; Leonardi, R.; Lesgourgues, J.; Levrier, F.; Lewis, A.; Liguori, M.; Lilje, P.B.; Linden-Vørnle, M.; López-Caniego, M.; Lubin, P.M.; Macías-Pérez, J.F.; Maggio, G.; Maino, D.; Mandolesi, N.; Mangilli, A.; Maris, M.; Martin, P.G.; Martínez-González, E.; Masi, S.; Matarrese, S.; McGehee, P.; Meinhold, P.R.; Melchiorri, A.; Mendes, L.; Mennella, A.; Migliaccio, M.; Mitra, S.; Miville-Deschênes, M.-A.; Moneti, A.; Montier, L.; Morgante, G.; Mortlock, D.; Moss, A.; Munshi, D.; Murphy, J.A.; Naselsky, P.; Nati, F.; Natoli, P.; Netterfield, C.B.; Nørgaard-Nielsen, H.U.; Noviello, F.; Novikov, D.; Novikov, I.; Oxborrow, C.A.; Paci, F.; Pagano, L.; Pajot, F.; Paoletti, D.; Pasian, F.; Patanchon, G.; Perdereau, O.; Perotto, L.; Perrotta, F.; Pettorino, V.; Piacentini, F.; Piat, M.; Pierpaoli, E.; Pietrobon, D.; Plaszczynski, S.; Pointecouteau, E.; Polenta, G.; Popa, L.; Pratt, G.W.; Prézeau, G.; Prunet, S.; Puget, J.-L.; Rachen, J.P.; Reach, W.T.; Rebolo, R.; Reinecke, M.; Remazeilles, M.; Renault, C.; Renzi, A.; Ristorcelli, I.; Rocha, G.; Rosset, C.; Rossetti, M.; Roudier, G.; Rowan-Robinson, M.; Rubiño-Martín, J.A.; Rusholme, B.; Sandri, M.; Santos, D.; Savelainen, M.; Savini, G.; Scott, D.; Seiffert, M.D.; Shellard, E.P.S.; Spencer, L.D.; Stolyarov, V.; Stompor, R.; Sudiwala, R.; Sunyaev, R.; Sutton, D.; Suur-Uski, A.-S.; Sygnet, J.-F.; Tauber, J.A.; Terenzi, L.; Toffolatti, L.; Tomasi, M.; Tristram, M.; Tucci, M.; Tuovinen, J.; Valenziano, L.; Valiviita, J.; Van Tent, B.; Vielva, P.; Villa, F.; Wade, L.A.; Wandelt, B.D.; Wehus, I.K.; White, M.; Yvon, D.; Zacchei, A.

    2016-01-01

    We present the most significant measurement of the cosmic microwave background (CMB) lensing potential to date (at a level of 40 sigma), using temperature and polarization data from the Planck 2015 full-mission release. Using a polarization-only estimator we detect lensing at a significance of 5 sigma. We cross-check the accuracy of our measurement using the wide frequency coverage and complementarity of the temperature and polarization measurements. Public products based on this measurement include an estimate of the lensing potential over approximately 70% of the sky, an estimate of the lensing potential power spectrum in bandpowers for the multipole range 40lensing potential power spectrum and that found in the best-fitting LCDM model based on the Planck temperature and polarization power spectra. Using the lensing likelihood alone we obtain a percent-level measurement of ...

  20. Scleral lenses in the management of keratoconus.

    Science.gov (United States)

    Schornack, Muriel M; Patel, Sanjay V

    2010-01-01

    To describe the use of Jupiter scleral lenses (Medlens Innovations, Front Royal, VA; and Essilor Contact Lenses, Inc., Dallas, TX) in the management of keratoconus. We performed a single-center retrospective chart review of our initial 32 patients with keratoconus evaluated for scleral lens wear. All patients were referred for scleral lens evaluation after exhausting other nonsurgical options for visual correction. Diagnostic lenses were used in the initial fitting process. If adequate fit could not be achieved with standard lenses, custom lenses were designed in consultation with the manufacturers' specialists. The following measures were evaluated for each patient: ability to tolerate and handle lenses, visual acuity with scleral lenses, number of lenses, and visits needed to complete the fitting process. Fifty-two eyes of 32 patients were evaluated for scleral lens wear. Of these, 12 patients (20 eyes) decided not to pursue scleral lens wear after initial evaluation. One patient (2 eyes) abandoned the fitting process after cataract surgery. The remaining 19 patients (30 eyes) were fit successfully. The average number of lenses ordered per eye was 1.5. The fitting process required an average of 2.8 visits. Standard lenses were prescribed for 23 eyes, and custom designs were needed for 7 eyes. Median best-corrected visual acuity improved from 20/40 (mean, 20/76) before scleral lens fitting to 20/20 (mean, 20/30) after fitting. Follow-up ranged from 3 to 32 months. Jupiter scleral lenses provide acceptable visual acuity and comfort in patients with keratoconus. The availability of diagnostic lenses facilitates the fitting process.

  1. Machine learning techniques to select Be star candidates. An application in the OGLE-IV Gaia south ecliptic pole field

    Science.gov (United States)

    Pérez-Ortiz, M. F.; García-Varela, A.; Quiroz, A. J.; Sabogal, B. E.; Hernández, J.

    2017-09-01

    Context. Optical and infrared variability surveys produce a large number of high quality light curves. Statistical pattern recognition methods have provided competitive solutions for variable star classification at a relatively low computational cost. In order to perform supervised classification, a set of features is proposed and used to train an automatic classification system. Quantities related to the magnitude density of the light curves and their Fourier coefficients have been chosen as features in previous studies. However, some of these features are not robust to the presence of outliers and the calculation of Fourier coefficients is computationally expensive for large data sets. Aims: We propose and evaluate the performance of a new robust set of features using supervised classifiers in order to look for new Be star candidates in the OGLE-IV Gaia south ecliptic pole field. Methods: We calculated the proposed set of features on six types of variable stars and also on a set of Be star candidates reported in the literature. We evaluated the performance of these features using classification trees and random forests along with the K-nearest neighbours, support vector machines, and gradient boosted trees methods. We tuned the classifiers with a 10-fold cross-validation and grid search. We then validated the performance of the best classifier on a set of OGLE-IV light curves and applied this to find new Be star candidates. Results: The random forest classifier outperformed the others. By using the random forest classifier and colours criteria we found 50 Be star candidates in the direction of the Gaia south ecliptic pole field, four of which have infrared colours that are consistent with Herbig Ae/Be stars. Conclusions: Supervised methods are very useful in order to obtain preliminary samples of variable stars extracted from large databases. As usual, the stars classified as Be stars candidates must be checked for the colours and spectroscopic characteristics

  2. Cylindrical diffractive lenses recorded on PVA/AA photopolymers

    Science.gov (United States)

    Fernández, R.; Gallego, S.; Márquez, A.; Navarro-Fuster, V.; Francés, J.; Neipp, C.; Beléndez, A.; Pascual, I.

    2016-04-01

    Photopolymers are optical recording materials appealing for many different applications such as holography, data storage, interconnectors, solar concentrations, or wave-guides fabrication. Recently the capacity of photopolymers to record diffractive optical elements (DOE's) has been investigated. Different authors have reported proposes to record DOE like fork gratings, photonics structures, lenses, sinusoidal, blazed or fork gratings. In these experiments there are different experimental set-ups and different photopolymers. In this work due to the improvement in the spatial light modulation technology together with the photopolymer science we propose a recording experimental system of DOE using a Liquid Cristal based on Silicon (LCoS) display as a master to store complex DOE like cylindrical lenses. This technology permits us an accurate control of the phase and the amplitude of the recording beam, with a very small pixel size. The main advantage of this display is that permit us to modify the DOE automatically, we use the software of the LCoS to send the voltage to each pixel In this work we use a photopolymer composed by acrylamide (AA) as polymerizable monomer and polyvinyl alcohol (PVA). We use a coverplated and index matched photopolymer to avoid the influence of the thickness variation on the transmitted light. In order to reproduce the material behaviour during polymerization, we have designed our model to simulate cylindrical lenses and used Fresnel propagation to simulate the light propagation through the DOE and analyze the focal plane and the properties of the recorded lenses.

  3. Comparison of objective lenses for multiphoton microscopy in turbid samples.

    Science.gov (United States)

    Singh, Avtar; McMullen, Jesse D; Doris, Eli A; Zipfel, Warren R

    2015-08-01

    Optimization of illumination and detection optics is pivotal for multiphoton imaging in highly scattering tissue and the objective lens is the central component in both of these pathways. To better understand how basic lens parameters (NA, magnification, field number) affect fluorescence collection and image quality, a two-detector setup was used with a specialized sample cell to separate measurement of total excitation from epifluorescence collection. Our data corroborate earlier findings that low-mag lenses can be superior at collecting scattered photons, and we compare a set of commonly used multiphoton objective lenses in terms of their ability to collect scattered fluorescence, providing guidance for the design of multiphoton imaging systems. For example, our measurements of epi-fluorescence beam divergence in the presence of scattering reveal minimal beam broadening, indicating that often-advocated over-sized collection optics are not as advantageous as previously thought. These experiments also provide a framework for choosing objective lenses for multiphoton imaging by relating the results of our measurements to various design parameters of the objectives lenses used.

  4. Polycapillary neutron lenses

    International Nuclear Information System (INIS)

    Mildner, D.F.R.

    1997-01-01

    The principle of multiple mirror reflection from smooth surfaces at small grazing angles enables the transport and guiding of high intensity slow neutron beams to locations of low background for neutron scattering and absorption experiments and to provide facilities for multiple instruments. Curved guides have been widely used at cold neutron facilities to remove the unwanted radiation (fast neutrons and gamma rays) from the beam without the use of filters. A typical guide has transverse dimensions of 50 mm and, with a radius of curvature of 1 km, transmits wavelengths longer than 5 A. Much tighter curves requires narrower transverse dimensions, otherwise there is little transmission. Typical neutron benders have a number of slots with transverse dimensions of ∼5 mm. Based on the same principle but using a different technology, recent developments in glass polycapillary fibers have produced miniature versions of neutron guides. Fibers with many thousands of channels having sizes of ∼ 10 μm enable beams of long wavelength neutrons (λ > 4 A) to be transmitted efficiently in a radius of curvature as small as a fraction of 1 m. A large collection of these miniature versions of neutron guides can be used to bend the neutron trajectories such that the incident beam can be focused. (author)

  5. In vitro adhesion of Acanthamoeba castellanii to soft contact lenses depends on water content and disinfection procedure.

    Science.gov (United States)

    Reverey, Julia F; Fromme, Roland; Leippe, Matthias; Selhuber-Unkel, Christine

    2014-08-01

    To compare the potential of different soft contact lenses to be contaminated with Acanthamoeba castellanii as a function of material parameters and cleaning procedures. Different unworn soft hydrogel and silicone hydrogel contact lenses were incubated with human pathogenic A. castellanii. The adhesion of the acanthamoebae was investigated on the contact lenses and put into relation to their material parameters. The efficacy of a recommended contact lens cleaning procedure in reducing A. castellanii adhesion was investigated. We found that material parameters such as elastic modulus, silicone content, ionic properties and swelling do not influence the adhesion of acanthamoebae to soft contact lenses. A material parameter that influenced adhesion significantly was the water content of the lens. With increasing water content, the adhesion of acanthamoebae increased. By following the cleaning instructions of the manufacturer the contamination of the lenses with A. castellanii could be reduced to a minimum, as shown both on contact lenses and in control experiments. With this study we show that for the tested lenses, the adhesion of A. castellanii to contact lenses is independent of the silicone content of the lens, but depends nonlinearly on the water content of the lens. Furthermore, we demonstrate that applying proper lens cleaning procedures minimizes the risk of acanthamoebae adhesion to contact lenses. Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  6. Braneworld Black Hole Gravitational Lensing

    International Nuclear Information System (INIS)

    Liang Jun

    2017-01-01

    A class of braneworld black holes, which I called as Bronnikov–Melnikov–Dehen (BMD) black holes, are studied as gravitational lenses. I obtain the deflection angle in the strong deflection limit, and further calculate the angular positions and magnifications of relativistic images as well as the time delay between different relativistic images. I also compare the results with those obtained for Schwarzschild and two braneworld black holes, i.e., the tidal Reissner-Nordström (R-N) and the Casadio–Fabbri–Mazzacurati (CFM) black holes. (paper)

  7. The Scales of Gravitational Lensing

    Directory of Open Access Journals (Sweden)

    Francesco De Paolis

    2016-03-01

    Full Text Available After exactly a century since the formulation of the general theory of relativity, the phenomenon of gravitational lensing is still an extremely powerful method for investigating in astrophysics and cosmology. Indeed, it is adopted to study the distribution of the stellar component in the Milky Way, to study dark matter and dark energy on very large scales and even to discover exoplanets. Moreover, thanks to technological developments, it will allow the measure of the physical parameters (mass, angular momentum and electric charge of supermassive black holes in the center of ours and nearby galaxies.

  8. Detection of brown dwarfs by the micro-lensing of unresolved stars

    CERN Document Server

    Baillon, Paul; Giraud-Héraud, Yannick; Kaplan, J; Baillon, Paul; Bouquet, Alain; Giraud-Héraud, Yannick; Kaplan, Jean

    1993-01-01

    The presence of brown dwarfs in the dark galactic halo could be detected through their gravitational lensing effect and experiments under way monitor about one million stars to observe a few lensing events per year. We show that if the photon flux from a galaxy is measured with a good precision, it is not necessary to resolve the stars and besides more events could be observed.

  9. Some aspects of powerful lasers and aspheric lenses design

    International Nuclear Information System (INIS)

    Metz, Jean de

    1976-01-01

    Gigawatt power glass lasers are described. Geometrical, interferometric, coherence and focusing aspects of the beam are measured. Design of disc amplifier is shown with high gain glass. Aspheric lenses are designed and tested for focussing these beams. Experiments of multi-breakdown in gas are done. We get fusion in plasma made by second harmonic frequency of our 1.06 μ beam. Effect of self-focussing on laser beam quality is studied. (author) [fr

  10. The kinematical structure of gravitationally lensed arcs

    NARCIS (Netherlands)

    Moller, O; Noordermeer, E

    2006-01-01

    In this paper, the expected properties of the velocity fields of strongly lensed arcs behind galaxy clusters are investigated. The velocity profile along typical lensed arcs is determined by ray-tracing light rays from a model source galaxy through parametric cluster toy models consisting of

  11. Modern scleral lenses part I: clinical features.

    NARCIS (Netherlands)

    Visser, E.S.; Visser, R.; Lier, H.J.J. van; Otten, H.M.

    2007-01-01

    PURPOSE: To evaluate the indications for modern scleral lenses and their clinical performance in patients who were fitted with scleral lenses at the authors' practices. METHODS: In this cross-sectional survey, all the necessary data were obtained at the first follow-up visit during the 5-month study

  12. Soft Lenses | Kuming | South African Medical Journal

    African Journals Online (AJOL)

    A series of cases fitted with Bionite soft lenses is described. Good results were obtained in bullous keratopathy, dry eyes, early and moderately advanced Stevens-Johnson syndrome and pemphigoid, and some cases of indolent corneal ulcers. The lenses appear to be a most effective replacement for tarsorrhaphy, haptic ...

  13. Ecoturismo en Ecuador: El caso del Oglán alto

    Directory of Open Access Journals (Sweden)

    Pedro Hernández Pardo

    2011-12-01

    Full Text Available Ecuador es un país con unos grandes recursos naturales que han sido explotados a lo largo de su historia, posee una gran biodiversidad, Amazonia, Sierra y Costa, y una gran  riqueza  cultural.  Una  forma  de  aprovechar  esos recursos  de  una  forma  sostenible  y  permitiendo  el desarrollo  económico  es  el  eco  turismo,  en  todas  sus tipologías. Para que el turismo sea sostenible hay que entender las necesidades, los activos potenciales y los valores culturales del área donde se va desarrollar. La creación de empleo estable y de calidad, debe ser parte de esa sostenibilidad, porque es fundamental para que la población  pueda  percibir  los  beneficios  del  turismo. Para conseguirlo   es   necesario   la   existencia   de emprendedores   capaces   de   formar   microempresas, pequeñas  y medianas  empresas,  que  sean  rentables  y generadoras de empleo. La cultura indígena amazónica es básicamente  comunitaria  y  agrícola  por  lo  que  es difícil la creación de actividades empresariales por esas comunidades.   Pero   desde   hace   ya   años,   estas comunidades indígenas,  están perdiendo su cultura, su lengua,  y  su  propia  vida  natural,  adquiriendo  valores occidentales que nada tienen que ver con los suyos. El eco turismo es una buena forma de recuperar sus valores, su cultura y sus tradiciones, y a la vez, una forma de asegurar su progreso economico respetando su hábitat natural   y   sus   recursos   de   una   forma   sostenible, permitiendo   que   actividades   destructivas   como   la madera y el petróleo, sean abandonadas. Un ejemplo lo tenemos en el Oglán Alto, donde la comunidad quechua “Pablo  López”  ha  decidido  proteger  su  patrimonio ancestral   mediante   la   creación   de   una   Estación Científica,  gracias  a  un  acuerdo  con  la  Universidad Central

  14. Blue-Light Filtering Spectacle Lenses: Optical and Clinical Performances.

    Science.gov (United States)

    Leung, Tsz Wing; Li, Roger Wing-Hong; Kee, Chea-Su

    2017-01-01

    To evaluate the optical performance of blue-light filtering spectacle lenses and investigate whether a reduction in blue light transmission affects visual performance and sleep quality. Experiment 1: The relative changes in phototoxicity, scotopic sensitivity, and melatonin suppression of five blue-light filtering plano spectacle lenses were calculated based on their spectral transmittances measured by a spectrophotometer. Experiment 2: A pseudo-randomized controlled study was conducted to evaluate the clinical performance of two blue-light filtering spectacle lenses (BF: blue-filtering anti-reflection coating; BT: brown-tinted) with a regular clear lens (AR) serving as a control. A total of eighty computer users were recruited from two age cohorts (young adults: 18-30 yrs, middle-aged adults: 40-55 yrs). Contrast sensitivity under standard and glare conditions, and colour discrimination were measured using standard clinical tests. After one month of lens wear, subjective ratings of lens performance were collected by questionnaire. All tested blue-light filtering spectacle lenses theoretically reduced the calculated phototoxicity by 10.6% to 23.6%. Although use of the blue-light filters also decreased scotopic sensitivity by 2.4% to 9.6%, and melatonin suppression by 5.8% to 15.0%, over 70% of the participants could not detect these optical changes. Our clinical tests revealed no significant decrease in contrast sensitivity either with (95% confidence intervals [CI]: AR-BT [-0.05, 0.05]; AR-BF [-0.05, 0.06]; BT-BF [-0.06, 0.06]) or without glare (95% CI: AR-BT [-0.01, 0.03]; AR-BF [-0.01, 0.03]; BT-BF [-0.02, 0.02]) and colour discrimination (95% CI: AR-BT [-9.07, 1.02]; AR-BF [-7.06, 4.46]; BT-BF [-3.12, 8.57]). Blue-light filtering spectacle lenses can partially filter high-energy short-wavelength light without substantially degrading visual performance and sleep quality. These lenses may serve as a supplementary option for protecting the retina from potential

  15. Blue-Light Filtering Spectacle Lenses: Optical and Clinical Performances

    Science.gov (United States)

    2017-01-01

    Purposes To evaluate the optical performance of blue-light filtering spectacle lenses and investigate whether a reduction in blue light transmission affects visual performance and sleep quality. Methods Experiment 1: The relative changes in phototoxicity, scotopic sensitivity, and melatonin suppression of five blue-light filtering plano spectacle lenses were calculated based on their spectral transmittances measured by a spectrophotometer. Experiment 2: A pseudo-randomized controlled study was conducted to evaluate the clinical performance of two blue-light filtering spectacle lenses (BF: blue-filtering anti-reflection coating; BT: brown-tinted) with a regular clear lens (AR) serving as a control. A total of eighty computer users were recruited from two age cohorts (young adults: 18–30 yrs, middle-aged adults: 40–55 yrs). Contrast sensitivity under standard and glare conditions, and colour discrimination were measured using standard clinical tests. After one month of lens wear, subjective ratings of lens performance were collected by questionnaire. Results All tested blue-light filtering spectacle lenses theoretically reduced the calculated phototoxicity by 10.6% to 23.6%. Although use of the blue-light filters also decreased scotopic sensitivity by 2.4% to 9.6%, and melatonin suppression by 5.8% to 15.0%, over 70% of the participants could not detect these optical changes. Our clinical tests revealed no significant decrease in contrast sensitivity either with (95% confidence intervals [CI]: AR–BT [–0.05, 0.05]; AR–BF [–0.05, 0.06]; BT–BF [–0.06, 0.06]) or without glare (95% CI: AR–BT [–0.01, 0.03]; AR–BF [–0.01, 0.03]; BT–BF [–0.02, 0.02]) and colour discrimination (95% CI: AR–BT [–9.07, 1.02]; AR–BF [–7.06, 4.46]; BT–BF [–3.12, 8.57]). Conclusion Blue-light filtering spectacle lenses can partially filter high-energy short-wavelength light without substantially degrading visual performance and sleep quality. These lenses may

  16. Scanning Miniature Microscopes without Lenses

    Science.gov (United States)

    Wang, Yu

    2009-01-01

    The figure schematically depicts some alternative designs of proposed compact, lightweight optoelectronic microscopes that would contain no lenses and would generate magnified video images of specimens. Microscopes of this type were described previously in Miniature Microscope Without Lenses (NPO - 20218), NASA Tech Briefs, Vol. 22, No. 8 (August 1998), page 43 and Reflective Variants of Miniature Microscope Without Lenses (NPO 20610), NASA Tech Briefs, Vol. 26, No. 9 (September 1999), page 6a. To recapitulate: In the design and construction of a microscope of this type, the focusing optics of a conventional microscope are replaced by a combination of a microchannel filter and a charge-coupled-device (CCD) image detector. Elimination of focusing optics reduces the size and weight of the instrument and eliminates the need for the time-consuming focusing operation. The microscopes described in the cited prior articles contained two-dimensional CCDs registered with two-dimensional arrays of microchannels and, as such, were designed to produce full two-dimensional images, without need for scanning. The microscopes of the present proposal would contain one-dimensional (line image) CCDs registered with linear arrays of microchannels. In the operation of such a microscope, one would scan a specimen along a line perpendicular to the array axis (in other words, one would scan in pushbroom fashion). One could then synthesize a full two-dimensional image of the specimen from the line-image data acquired at one-pixel increments of position along the scan. In one of the proposed microscopes, a beam of unpolarized light for illuminating the specimen would enter from the side. This light would be reflected down onto the specimen by a nonpolarizing beam splitter attached to the microchannels at their lower ends. A portion of the light incident on the specimen would be reflected upward, through the beam splitter and along the microchannels, to form an image on the CCD. If the

  17. Users' and nonusers' evaluations of the CPF 550 lenses.

    Science.gov (United States)

    Morrissette, D L; Mehr, E B; Keswick, C W; Lee, P N

    1984-11-01

    Thirty-six subjects completed questionnaires on their experiences wearing the CPF 550 lenses. Twenty-six subjects [21 with retinitis pigmentosa (RP)] were users of the 550's and 10 subjects (6 with RP) were nonusers who had rejected the 550's after a trial period. Subjects were asked about such factors as effects on adaptation time, ocular comfort, visual functioning, acceptability of tint strength in various lighting conditions, cosmetic appearance, effects of weather, and replacement intent. Users reported reduced adaptation time in changes of illumination, increased ocular comfort, improved visual functioning with the exception of poor color discrimination, and cosmetic acceptability. Satisfaction with tint strength varied with degree of illumination; usefulness in different types of weather also varied depending on the condition. Nonusers' responses were mixed; they were less likely to report improvements with the CPF 550 lenses compared to the users' group.

  18. Photometry of High-Redshift Gravitationally Lensed Type Ia Supernovae

    Science.gov (United States)

    Haynie, Annastasia

    2018-01-01

    Out of more than 1100 well-identified Type Ia Supernovae, only roughly 10 of them are at z> 1.5. High redshift supernovae are hard to detect but this is made easier by taking advantage of the effects of gravitational lensing, which magnifies objects in the background field of massive galaxy clusters. Supernova Nebra (z= ~1.8), among others, was discovered during observations taken as part of the RELICS survey, which focused on fields of view that experience strong gravitational lensing effects. SN Nebra, which sits behind galaxy cluster Abell 1763, is magnified and therefore appears closer and easier to see than with HST alone. Studying high-redshift supernovae like SN Nebra is an important step towards creating cosmological models that accurately describe the behavior of dark energy in the early Universe. Recent efforts have been focused on improving photometry and the building and fitting of preliminary light curves.

  19. Modern scleral lenses part I: clinical features.

    Science.gov (United States)

    Visser, Esther-Simone; Visser, Rients; van Lier, Henk J J; Otten, Henny M

    2007-01-01

    To evaluate the indications for modern scleral lenses and their clinical performance in patients who were fitted with scleral lenses at the authors' practices. In this cross-sectional survey, all the necessary data were obtained at the first follow-up visit during the 5-month study period. There were four types of scleral lenses: spherical, front-surface toric, back-surface toric, and bitoric. The preformed scleral lens fitting technique developed at Visser Contact Lens Practice was used in all patients. The lenses were cut by precise Sub Micron Lathing from a Boston Equalens II blank at Procornea. Visual acuity and slitlamp findings were recorded. A specially designed classification for scleral lens fitting was used to investigate clinical performance. The largest proportion of the 178 patients (284 eyes) were diagnosed with keratoconus (143 [50.4%] eyes) followed by postpenetrating keratoplasty (56 [19.7%] eyes). The remaining diagnoses were irregular astigmatism, keratitis sicca, corneal dystrophy, and multiple diagnoses. The ratio of spherical to back-surface toric designs was 1:1.1. Clinical examination showed sharp increases in visual acuity (median increase, 0.45) and safe physiologic responses of the anterior eye. All the patients could continue to wear scleral lenses, with 79.2% with the same lens parameters. Several types of corneal abnormality were managed successfully with modern scleral lenses. The main indication was optical correction of an irregular corneal surface. Satisfactory clinical performance meant that all the patients could continue to wear their scleral lenses.

  20. Investigations of Galaxy Clusters Using Gravitational Lensing

    Energy Technology Data Exchange (ETDEWEB)

    Wiesner, Matthew P. [Northern Illinois Univ., DeKalb, IL (United States)

    2014-08-01

    In this dissertation, we discuss the properties of galaxy clusters that have been determined using strong and weak gravitational lensing. A galaxy cluster is a collection of galaxies that are bound together by the force of gravity, while gravitational lensing is the bending of light by gravity. Strong lensing is the formation of arcs or rings of light surrounding clusters and weak lensing is a change in the apparent shapes of many galaxies. In this work we examine the properties of several samples of galaxy clusters using gravitational lensing. In Chapter 1 we introduce astrophysical theory of galaxy clusters and gravitational lensing. In Chapter 2 we examine evidence from our data that galaxy clusters are more concentrated than cosmology would predict. In Chapter 3 we investigate whether our assumptions about the number of galaxies in our clusters was valid by examining new data. In Chapter 4 we describe a determination of a relationship between mass and number of galaxies in a cluster at higher redshift than has been found before. In Chapter 5 we describe a model of the mass distribution in one of the ten lensing systems discovered by our group at Fermilab. Finally in Chapter 6 we summarize our conclusions.

  1. Modern scleral lenses: Mini versus large.

    Science.gov (United States)

    Fadel, Daddi

    2017-08-01

    The evolution of scleral lenses has led to new formulations of scleral fitting concepts and designs. The diameters of modern scleral lenses have been overhauled too and they are smaller comparing to the original ones. Nowadays, prescription of mini-sclerals supposedly seems in major extension and it appears indeed the necessity of some practitioner to differentiate the smaller mini-scleral lenses from larger mini-scleral lenses empathizing that they are the "smaller" ones. Therefore, it is maybe, necessary a definition of mini-scleral lenses referring to the landing zone width in relation to the horizontal visible iris diameter (HVID) and the limbus extension. The choice of the total diameter is crucial for a successful fitting and it depends majorly on patient's topographic patterns and anatomic factors. However, there are other important criteria for the selection of the scleral lens diameter based on oxygen supply, bubbles formation, mechanical stress on a toric sclera, ocular surface disease protection, entity of the vault over the cornea and distribution of the lens weight on the sclera. The advantages of mini-scleral lenses are various nonetheless in some cases large lenses are necessary. This paper presents a review of the benefits and disadvantages of both mini and large scleral lenses analyzing the conditions in which it may be better to prefer one diameter to another. A suggestion may be that to start fitting the smallest lens as possible, depending on the dimension of HVID and limbus width and consider larger lenses only when issues occur. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  2. 'Colored' and Decorative Contact Lenses: A Prescription Is a Must

    Science.gov (United States)

    ... these looks with decorative contact lenses (sometimes called “fashion,” “costume,” or “colored” contact lenses). These lenses don’ ... Wear Decorative or “Colored” Contact Lenses An entertainment industry artist from American Horror Story and the FDA ...

  3. Tevatron Electron Lenses: Design and Operation

    Energy Technology Data Exchange (ETDEWEB)

    Shiltsev, Vladimir; /Fermilab; Bishofberger, Kip; /Los Alamos; Kamerdzhiev, Vsevolod; /Fermilab; Kozub, Sergei; /Serpukhov, IHEP; Kufer, Matthew; Kuznetsov, Gennady; Martinez, Alexander; Olson, Marvin; Pfeffer, Howard; Saewert, Greg; Scarpine, Vic; /Fermilab /SLAC /Fermilab /Serpukhov, IHEP /Novosibirsk, IYF /Serpukhov, IHEP /Fermilab

    2008-08-01

    The beam-beam effects have been the dominating sources of beam loss and lifetime limitations in the Tevatron proton-antiproton collider [1]. Electron lenses were originally proposed for compensation of electromagnetic long-range and head-on beam-beam interactions of proton and antiproton beams [2]. Results of successful employment of two electron lenses built and installed in the Tevatron are reported in [3,4,5]. In this paper we present design features of the Tevatron electron lenses (TELs), discuss the generation of electron beams, describe different modes of operation and outline the technical parameters of various subsystems.

  4. Thin Film Coating Technology For Ophthalmic Lenses

    Science.gov (United States)

    Guenther, K. H.

    1986-05-01

    Coating of ophthalmic lenses is an application of high-vacuum coating technology which must satisfy not only physical and technical requirements but also customer demands with respect to aesthetics, color fidelity, and exchangeability of coated ophthalmic lenses. Because this application caters specifically to the consumer market, ophthalmic lenses are subject to certain fashion trends which frequently require quick adaptation of the coating technique. The state-of-the-art of ophthalmic lens coating is reviewed in this paper, with particular emphasis on the durability requirements in daily use by untrained consumers as well as on the applicable testing methods.

  5. Structural changes in the hot Algol OGLE-LMC-DPV-097 and its disk related to its long-cycle

    Science.gov (United States)

    L, J. Garcés; Mennickent, R. E.; Djurašević, Gojko; Poleski, R.; Soszyński, I.

    2018-03-01

    Double Periodic Variables (DPVs) are hot Algols showing a long photometric cycle of uncertain origin. We report the discovery of changes in the orbital light curve of OGLE-LMC-DPV-097 which depend on the phase of its long photometric cycle. During the ascending branch of the long-cycle the brightness at the first quadrature is larger than during the second quadrature, during the maximum of the long-cycle the brightness is basically the same at both quadratures, during the descending branch the brightness at the second quadrature is larger than during the first quadrature and during the minimum of the long-cycle the secondary minimum disappears. We model the light curve at different phases of the long-cycle and find that the data are consistent with changes in the properties of the accretion disk and two disk spots. The disk's size and temperature change with the long-cycle period. We find a smaller and hotter disk at minimum and larger and cooler disk at maximum. The spot temperatures, locations and angular sizes also show variability during the long-cycle.

  6. OGLE-2017-BLG-0373Lb: A Jovian Mass-Ratio Planet Exposes A New Accidental Microlensing Degeneracy

    Science.gov (United States)

    Skowron, J.; Ryu, Y.-H.; Hwang, K.-H.; Udalski, A.; Mrǎłz, P.; Kozłowski, S.; Soszyński, I.; Pietrukowicz, P.; Szymański, P. K.; Poleski, R.; Ulaczyk, K.; Pawlak, M.; Rybicki, K.; Iwanek, P.; Albrow, M. D.; Chung, S.-J.; Gould, A.; Han, C.; Jung, Y. K.; Shin, I.-G.; Shvartzvald, Y.; Yee, J. C.; Zang, W.; Zhu, W.; Cha, S.-M.; Kim, D.-J.; Kim, H.-W.; Kim, S.-L.; Lee, C.-U.; Lee, D.-J.; Lee, Y.; Park, B.-G.; Pogge, R. W.

    2018-03-01

    We report the discovery of microlensing planet OGLE-2017-BLG-0373Lb. We show that while the planet-host system has an unambiguous microlens topology, there are two geometries within this topology that fit the data equally well, which leads to a factor 2.5 difference in planet-host mass ratio, i.e., q=1.5×10-3 vs. q=0.6×10-3. We show that this is an "accidental degeneracy" in the sense that it is due to a gap in the data. We dub it "the caustic-chirality degeneracy". We trace the mathematical origins of this degeneracy, which should enable similar degenerate solutions to be easily located in the future. A Bayesian estimate, based on a Galactic model, yields a host mass M=0.25+0.30-0.15 M⊙ at a distance DL=5.9+1.3-1.95 kpc. The lens-source relative proper motion is relatively fast, μ=9 mas/yr, which implies that the host mass and distance can be determined by high-resolution imaging after about 10 years. The same observations could in principle resolve the discrete degeneracy in q, but this will be more challenging.

  7. Cosmological applications of strong gravitational lensing

    DEFF Research Database (Denmark)

    Paraficz, Danuta

    value of the energy density of the two above components, together with measuring the Hubble constant that determines the age of the Universe, is a major goal of modern astrophysics. An interesting method for estimating these parameters is strong gravitational lensing of quasars (QSOs). As shown...... by Refsdal (1964), H0, !m and !! can be measured based on the time delay ("t) between multiply lensed images of QSOs, because "t depends on H0 and on the distances to lens and source, hence!m and !!. Determination of cosmological parameters using gravitational lensing suffers from some degeneracies......, but it is based on well understood physics and unlike distance ladder methods there are no calibration issues. Moreover, it has an advantage over some of the leading methods (such as Type Ia SNe) in that it is a purely cosmological approach. In this thesis, the property of strong gravitational lensing - time...

  8. Characterisation of adaptive fluidic silicone membrane lenses

    CSIR Research Space (South Africa)

    Schneider, F

    2009-09-01

    Full Text Available In this paper the auhtors compare the performance and optical quality of two types of adaptive fluidic silicone-membrane lenses. The membranes feature either a homogeneous thickness, or they are shaped resulting in an inhomogeneous cross...

  9. Disposable contact lenses in penetrating keratoplasty.

    Science.gov (United States)

    Arora, R; Gupta, S; Taneja, M; Raina, U K; Mehta, D K

    2000-07-01

    To evaluate the therapeutic efficacy of disposable contact lenses in management of complications after keratoplasty. Twenty-eight patients with various post keratoplasty complications were fit with disposable contact lenses (45% Vifilcon A and 55% water content). Indications for lens use included persistent epithelial defects, wound leak, graft edema, dry eye and protection of normal corneal epithelium. Success was obtained with the therapeutic use of disposable lenses in 20 of the 28 cases. The best results were seen in maintenance and restoration of healthy ocular surface and small wound leaks. Stromal graft edema with no epithelial involvement was the major area of therapeutic failure. Disposable contact lenses are an attractive low cost option in the management of complications after keratoplasty. They are particularly useful in maintaining a healthy ocular surface, providing symptomatic relief and avoiding resurgery in patients with small wound leaks.

  10. Gravitational Lensing Mass Mapping with Gaussian Processes

    Science.gov (United States)

    Schneider, Michael; Ng, Karen; Dawson, William; Marshall, Phil; Meyers, Joshua; Bard, Deborah

    2018-01-01

    We infer gravitational lensing shear and convergence fields from galaxy ellipticity catalogs under a Gaussian Process prior for the lensing potential. We demonstrate the performance of our algorithm with simulated Gaussian-distributed cosmological lensing shear maps and a reconstruction of the mass distribution of the merging galaxy cluster Abell 781 using galaxy ellipticities measured with the Deep Lens Survey. Given interim posterior samples of lensing shear or convergence fields on the sky, we describe an algorithm to infer cosmological parameters via lens field marginalization. In the most general formulation of our algorithm we make no assumptions about weak shear orGaussian-distributed shape noise or shears. Because we require solutions and matrix determinants of a linear system of dimension that scales with the number of galaxies, we present computational performance metrics with approximate algorithms that introduce sparsity in the Gaussian Process kernel.

  11. Thirty Meter Telescopes and Gravitational Lensing

    OpenAIRE

    Carlberg, R. G.

    2004-01-01

    Diffraction limited 30m class telescopes will play an important role in gravitational lensing studies, coming online in approximately 2015. As imaging telescopes they will complement the ~6m JWST, probing to smaller angular scales in greatly magnified objects near critical lines and for measuring shear of objects below the JWST angular scale, such as luminous super-star clusters at high redshift. The high source density will allow more detailed mass mapping in the weak lensing regime and will...

  12. Comments on the Gravitational lensing Magnification

    OpenAIRE

    Takashi, HAMANA; Astronomical Institute, Tohoku University

    1998-01-01

    We rederive a relation between gravitational lensing magnification relative to the standard Friedmann distance and one relative to the Dyer-Roeder distance by investigating the null geodesic deviation equation. We show that the relation comes from a natural consequence of the definition of the lensing magnification matrices and is not based on the averaging of the magnifications, which has conventionally been used to derive it. We therefore conclude that the relation is true for each individu...

  13. Comments on the gravitational lensing magnification

    OpenAIRE

    Hamana, Takashi

    1998-01-01

    We rederive a relation between gravitational lensing magnification relative to the standard Friedmann distance and one relative to the Dyer-Roeder distance by investigating the null geodesic deviation equation. We show that the relation comes from a natural consequence of the definition of the lensing magnification matrices and is not based on the averaging of the magnifications, which has conventionally been used to derive it. We therefore conclude that the relation is true for each individu...

  14. Planck 2015 results: XV. Gravitational lensing

    DEFF Research Database (Denmark)

    Ade, P. A R; Aghanim, N.; Arnaud, M.

    2016-01-01

    We present the most significant measurement of the cosmic microwave background (CMB) lensing potential to date (at a level of 40σ), using temperature and polarization data from the Planck 2015 full-mission release. Using a polarization-only estimator, we detect lensing at a significance of 5σ. We......-scale temperature anisotropies, detecting a cross-correlation at the 3σ level, as expected because of dark energy in the concordance ΛCDM model....

  15. Electron Lenses for particle collimation in LHC

    CERN Document Server

    Shiltsev, V

    2008-01-01

    Electron Lenses built and installed in Tevatron have proven themselves as safe and very reliable instruments which can be effectively used in hadron collider operation for a number of applications, including compensation of beam-beam effects , DC beam removal from abort gaps , as a diagnostic tool. In this presentation we – following original proposal – consider in more detail a possibility of using electron lenses with hollow electron beam for ion and proton collimation in LHC.

  16. Revised Unfilling Procedure for Solid Lithium Lenses

    Energy Technology Data Exchange (ETDEWEB)

    Leveling, A.; /Fermilab

    2003-06-03

    A procedure for unfilling used lithium lenses to has been described in Pbar Note 664. To date, the procedure has been used to disassemble lenses 20, 21, 17, 18, and 16. As a result of this work, some parts of the original procedure were found to be time consuming and ineffective. Modifications to the original procedure have been made to streamline the process and are discussed in this note. The revised procedure is included in this note.

  17. Predicting gravitational lensing by stellar remnants

    Science.gov (United States)

    Harding, Alexander J.; Stefano, R. Di; Lépine, S.; Urama, J.; Pham, D.; Baker, C.

    2018-03-01

    Gravitational lensing provides a means to measure mass that does not rely on detecting and analysing light from the lens itself. Compact objects are ideal gravitational lenses, because they have relatively large masses and are dim. In this paper, we describe the prospects for predicting lensing events generated by the local population of compact objects, consisting of 250 neutron stars, five black holes, and ≈35 000 white dwarfs. By focusing on a population of nearby compact objects with measured proper motions and known distances from us, we can measure their masses by studying the characteristics of any lensing event they generate. Here, we concentrate on shifts in the position of a background source due to lensing by a foreground compact object. With Hubble Space Telescope, JWST, and Gaia, measurable centroid shifts caused by lensing are relatively frequent occurrences. We find that 30-50 detectable events per decade are expected for white dwarfs. Because relatively few neutron stars and black holes have measured distances and proper motions, it is more difficult to compute realistic rates for them. However, we show that at least one isolated neutron star has likely produced detectable events during the past several decades. This work is particularly relevant to the upcoming data releases by the Gaia mission and also to data that will be collected by JWST. Monitoring predicted microlensing events will not only help to determine the masses of compact objects, but will also potentially discover dim companions to these stellar remnants, including orbiting exoplanets.

  18. OGLE-2015-BLG-0479LA,B: BINARY GRAVITATIONAL MICROLENS CHARACTERIZED BY SIMULTANEOUS GROUND-BASED AND SPACE-BASED OBSERVATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Han, C. [Department of Physics, Chungbuk National University, Cheongju 361-763 (Korea, Republic of); Udalski, A.; Szymański, M. K.; Soszyński, I.; Skowron, J.; Mróz, P.; Poleski, R. [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland); Gould, A.; Zhu, Wei; Fausnaugh, M.; Gaudi, B. S.; Wibking, B. [Department of Astronomy, Ohio State University, 140 W. 18th Avenue, Columbus, OH 43210 (United States); Street, R. A. [School of Physics and Astronomy, Queen Mary University of London, Mile End Road, London E1 4NS (United Kingdom); Yee, J. C. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Beichman, C.; Novati, S. Calchi [NASA Exoplanet Science Institute, MS 100-22, California Institute of Technology, Pasadena, CA 91125 (United States); Bryden, C.; Henderson, Calen B.; Shvartzvald, Y. [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, CA 91109 (United States); Carey, S. [Spitzer Science Center, MS 220-6, California Institute of Technology, Pasadena, CA (United States); Collaboration: (The Spitzer Microlensing Team; (The OGLE Collaboration; (The RoboNet collaboration; (The MiNDSTEp Consortium; (The μ FUN Collaboration; and others

    2016-09-01

    We present a combined analysis of the observations of the gravitational microlensing event OGLE-2015-BLG-0479 taken both from the ground and by the Spitzer Space Telescope . The light curves seen from the ground and from space exhibit a time offset of ∼13 days between the caustic spikes, indicating that the relative lens-source positions seen from the two places are displaced by parallax effects. From modeling the light curves, we measure the space-based microlens parallax. Combined with the angular Einstein radius measured by analyzing the caustic crossings, we determine the mass and distance of the lens. We find that the lens is a binary composed of two G-type stars with masses of ∼1.0 M {sub ⊙} and ∼0.9 M {sub ⊙} located at a distance of ∼3 kpc. In addition, we are able to constrain the complete orbital parameters of the lens thanks to the precise measurement of the microlens parallax derived from the joint analysis. In contrast to the binary event OGLE-2014-BLG-1050, which was also observed by Spitzer, we find that the interpretation of OGLE-2015-BLG-0479 does not suffer from the degeneracy between (±, ±) and (±, ∓) solutions, confirming that the four-fold parallax degeneracy in single-lens events collapses into the two-fold degeneracy for the general case of binary-lens events. The location of the blend in the color–magnitude diagram is consistent with the lens properties, suggesting that the blend is the lens itself. The blend is bright enough for spectroscopy and thus this possibility can be checked from future follow-up observations.

  19. Gravitationally Lensed Quasars in Gaia: II. Discovery of 24 Lensed Quasars

    Science.gov (United States)

    Lemon, Cameron A.; Auger, Matthew W.; McMahon, Richard G.; Ostrovski, Fernanda

    2018-04-01

    We report the discovery, spectroscopic confirmation and preliminary characterisation of 24 gravitationally lensed quasars identified using Gaia observations. Candidates were selected in the Pan-STARRS footprint with quasar-like WISE colours or as photometric quasars from SDSS, requiring either multiple detections in Gaia or a single Gaia detection near a morphological galaxy. The Pan-STARRS grizY images were modelled for the most promising candidates and 60 candidate systems were followed up with the William Herschel Telescope. 13 of the lenses were discovered as Gaia multiples and 10 as single Gaia detections near galaxies. We also discover 1 lens identified through a quasar emission line in an SDSS galaxy spectrum. The lenses have median image separation 2.13″ and the source redshifts range from 1.06 to 3.36. 4 systems are quadruply-imaged and 20 are doubly-imaged. Deep CFHT data reveal an Einstein ring in one double system. We also report 12 quasar pairs, 10 of which have components at the same redshift and require further follow-up to rule out the lensing hypothesis. We compare the properties of these lenses and other known lenses recovered by our search method to a complete sample of simulated lenses to show the lenses we are missing are mainly those with small separations and higher source redshifts. The initial Gaia data release only catalogues all images of ˜ 30% of known bright lensed quasars, however the improved completeness of Gaia data release 2 will help find all bright lensed quasars on the sky.

  20. Distribution of fission products in graphite sleeves and blocks of the eleventh and twelfth OGL-1 fuel assemblies

    International Nuclear Information System (INIS)

    Hayashi, Kimio; Fukuda, Kousaku; Kikuchi, Teruo; Tsuruta, Harumichi.

    1994-06-01

    The 11th and 12th fuel assemblies were irradiated in an in-pile gas loop, OGL-1, installed in the Japan Materials Testing Reactor (JMTR) of Japan Atomic Energy Research Institute (JAERI). Distribution of fission products in the graphite sleeves and blocks of the assemblies was measured by gamma-ray spectrometry. The 11th fuel assembly was aimed at testing the irradiation performance of mass product fuels in trial manufacturing of the first charge fuel for the High Temperature Engineering Test Reactor (HTTR) in relatively short irradiation, and the 12th assembly in long-term irradiation. The 12th assembly attained a burnup approximately as high as that of the HTTR driver fuel design. In the graphite sleeve of the 11th assembly, high concentration peaks of fission products were found in the axial distribution. Exposure of failed fuel particles was not detected on the surface of fuel compacts, while fissures of graphite matrix at overcoat boundaries were observed on the surface. These results led to a presumption that fission products, which were released from failed particles located inside of the fuel compact, was easily transported through the fissures of the matrix to the inner surface of the sleeve. In the graphite sleeve of the 12th assembly, 110m Ag was detected together with other fission products of 137 Cs, 134 Cs etc. Silver-110m showed characteristic distribution: this nuclides was less concentrated at the region with highly concentrated 60 Co which is presumed to have been transported from melted sheath material of thermocouples to the graphite sleeve. It was inferred from the distribution that the transport behavior of 110m Ag had been influenced by co-sorption or by pore structure change in the graphite material of the sleeve, which had been induced by metallic elements including cobalt. (author)

  1. Revisiting the Microlensing Event OGLE 2012-BLG-0026: A Solar Mass Star with Two Cold Giant Planets

    Science.gov (United States)

    Beaulieu, J.-P.; Bennett, D. P.; Batista, V.; Fukui, A.; Marquette, J.-B.; Brillant, S.; Cole, A. A.; Rogers, L. A.; Sumi, T.; Abe, F.

    2016-01-01

    Two cold gas giant planets orbiting a G-type main-sequence star in the galactic disk were previously discovered in the high-magnification microlensing event OGLE-2012-BLG-0026. Here, we present revised host star flux measurements and a refined model for the two-planet system using additional light curve data. We performed high angular resolution adaptive optics imaging with the Keck and Subaru telescopes at two epochs while the source star was still amplified. We detected the lens flux, H = 16.39 +/- 0.08. The lens, a disk star, is brighter than predicted from the modeling in the original study. We revisited the light curve modeling using additional photometric data from the B and C telescope in New Zealand and CTIO 1.3 m H-band light curve. We then include the Keck and Subaru adaptive optic observation constraints. The system is composed of an approximately 4-9 Gyr lens star of M(sub lens) = 1.06 +/- 0.05 solar mass at a distance of D(sub lens) = 4.0 +/- 0.3 kpc, orbited by two giant planets of 0.145 +/- 0.008 M(sub Jup) and 0.86 +/- 0.06 M(sub Jup), with projected separations of 4.0 +/- 0.5 au and 4.8 +/- 0.7 au, respectively. Because the lens is brighter than the source star by 16 +/- 8% in H, with no other blend within one arcsec, it will be possible to estimate its metallicity using subsequent IR spectroscopy with 8-10 m class telescopes. By adding a constraint on the metallicity it will be possible to refine the age of the system.

  2. Racemisation and human cataract. D-Ser, D-Asp/Asn and D-Thr are higher in the lifelong proteins of cataract lenses than in age-matched normal lenses.

    Science.gov (United States)

    Hooi, Michelle Yu Sung; Truscott, Roger J W

    2011-06-01

    ASTRACT: Several amino acids were found to undergo progressive age-dependent racemisation in the lifelong proteins of normal human lenses. The two most highly racemised were Ser and Asx. By age 70, 4.5% of all Ser residues had been racemised, along with >9% of Asx residues. Such a high level of inversion, equivalent to between 2 and 3 D- amino acids per polypeptide chain, is likely to induce significant denaturation of the crystallins in aged lenses. Thr, Glx and Phe underwent age-dependent racemisation to a smaller degree. In model experiments, D- amino acid content could be increased simply by exposing intact lenses to elevated temperature. In cataract lenses, the extent of racemisation of Ser, Asx and Thr residues was significantly greater than for age-matched normal lenses. This was true, even for cataract lenses removed from patients at the earliest ages where age-related cataract is observed clinically. Racemisation of amino acids in crystallins may arise due to prolonged exposure of these proteins to ocular temperatures and increased levels of racemisation may play a significant role in the opacification of human lenses.

  3. DESIGN OF THE MULTIORDER INTRAOCULAR LENSES

    Directory of Open Access Journals (Sweden)

    V. G. Kolobrodov

    2015-01-01

    Full Text Available Intraocular lenses (IOLs are used to replace the natural crystalline lens of the eye. Just few basic designs of IOLs are used clinically. Multiorder diffractive lenses (MODL which operate simultaneously in several diffractive orders were proposed to decrease the chromatic aberration. Properties analysis of MODL showed a possibility to use them to develop new designs of IOLs. The purpose of this paper was to develop a new method of designing of multiorder intraocular lenses with decreased chromatic aberration. The theoretical research of the lens properties was carried out. The diffraction efficiency dependence with the change of wavelength was studied. A computer simulation of MODL in a schematic model of the human eye was carried out. It is found the capability of the multiorder diffractive lenses to focus polychromatic light into a segment on the optical axis with high diffraction efficiency. At each point of the segment is present each component of the spectral range, which will build a color image in combination. The paper describes the new design method of intraocular lenses with reduced chromaticism and with endless adaptation. An optical system of an eye with an intraocular lens that provides sharp vision of objects located at a distance of 700 mm to infinity is modeled.

  4. Modern scleral contact lenses: A review.

    Science.gov (United States)

    van der Worp, Eef; Bornman, Dina; Ferreira, Daniela Lopes; Faria-Ribeiro, Miguel; Garcia-Porta, Nery; González-Meijome, José M

    2014-08-01

    Scleral contact lenses (ScCL) have gained renewed interest during the last decade. Originally, they were primarily used for severely compromised eyes. Corneal ectasia and exposure conditions were the primary indications. However, the indication range of ScCL in contact lens practices seems to be expanding, and it now increasingly includes less severe and even non-compromised eyes, too. All lenses that partly or entirely rest on the sclera are included under the name ScCL in this paper; although the Scleral Lens Education Society recommends further classification. When a lens partly rests on the cornea (centrally or peripherally) and partly on the sclera, it is called a corneo-scleral lens. A lens that rests entirely on the sclera is classified as a scleral lens (up to 25 mm in diameter maximum). When there is full bearing on the sclera, further distinctions of the scleral lens group include mini-scleral and large-scleral lenses. This manuscript presents a review of the current applications of different ScCL (all types), their fitting methods, and their clinical outcomes including potential adverse events. Adverse events with these lenses are rare, but the clinician needs to be aware of them to avoid further damage in eyes that often are already compromised. The use of scleral lenses for non-pathological eyes is discussed in this paper. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  5. Temperature changes in contact lenses in connection with radiation from infrared heaters.

    Science.gov (United States)

    Lövsund, P; Nilsson, S E; Oberg, P A

    1979-09-01

    A number of reports have appeared over the past few years with warnings about the wearing of contact lenses in certain trades involving exposure to are flash. In view of these reports and in light of knowledge on the marked absorption by contact lenses, within the infrared (IR) region, temperature changes were measured in soft contact lenses under radiation from IR heaters used, for example, in the motor industry for drying paint. The lenses were tested while free-hanging and when applied to rabbit eyes. Great increases in temperature were noted with one of the heaters at a distance corresponding to "safe." During 10 min of exposure the temperature of a free-hanging lens rose from 21 to 59 degrees C, whereas the temperature in the surrounding air increased only from 26 to 30 degrees C. The final temperature of the lens was thus 29 degrees C higher than that of the air. In lenses applied to rabbit eyes the temperature rose within only 0.5, 1.0, and 1.5 min from approximately 33 degrees C to about 44, 49, and 51 degrees C, respectively; the air temperature rose from 25 to only 28 degrees C. In other words, the ultimate lens temperature was 23 degrees C higher than the ambient air temperature. In the rabbit experiments most of the lenses dried out completely. There would thus seem to be considerable risk of contact lenses drying and becoming adherent to and damaging the corneal surface among workers exposed to powerful radiation from IR radiators (IR heaters), unless they use efficient eye protectors. IR heaters appear to be associated with greater hazards than are flashes, since there is no warning from powerful visible light and because they are capable of causing a very rapid increase in temperature.

  6. Temperature changes in contact lenses in connection with radiation from welding arcs.

    Science.gov (United States)

    Lövsund, P; Nilsson, S E; Lindh, H; Oberg, P A

    1979-09-01

    Because of reports of risks associated with the use of contact lenses during exposure to welding arcs, the temperature changes in soft contact lenses were recorded in connection with certain types of welding [manual metal arc (MMA) welding, tungsten inert-gas (TIG) welding, and metal inert-gas (MIG) welding], both with free-hanging lenses and lenses applied to the eyes of anesthetized rabbits. A great increase in temperature was noted, especially with MMA welding. At a distance of 0.4 m the temperature of a lens on a rabbit eye rose from about 35 to 50 degrees C within 6 min, whereas the air temperature only increased from 23 to 30 degrees C. The increase was the greatest at the beginning of the welding period. Most of the lenses completely dried out during the experiment, and there would seem to be a potential risk that the lens would adhere to the cornea. One safety glass screen (DIN 10 A) proved effective in preventing the rise in temperature in contact lenses during MMA welding. Even though it is impossible to direct the eyes at the arc for a prolonged period of time, the use of contact lenses in connection with at least certain types of welding is not to be recommended without the use of a suitable safety glass screen (or safety glasses). With regard to the large number of particles in the welding environment, also a risk factor for contact lens wearers, it is doubtful whether even safety glasses or screens are satisfactory unless they fit closely.

  7. Gravitational Lensing from a Spacetime Perspective

    Directory of Open Access Journals (Sweden)

    Perlick Volker

    2004-09-01

    Full Text Available The theory of gravitational lensing is reviewed from a spacetime perspective, without quasi-Newtonian approximations. More precisely, the review covers all aspects of gravitational lensing where light propagation is described in terms of lightlike geodesics of a metric of Lorentzian signature. It includes the basic equations and the relevant techniques for calculating the position, the shape, and the brightness of images in an arbitrary general-relativistic spacetime. It also includes general theorems on the classification of caustics, on criteria for multiple imaging, and on the possible number of images. The general results are illustrated with examples of spacetimes where the lensing features can be explicitly calculated, including the Schwarzschild spacetime, the Kerr spacetime, the spacetime of a straight string, plane gravitational waves, and others.

  8. Cosmological applications of strong gravitational lensing

    DEFF Research Database (Denmark)

    Paraficz, Danuta

    value of the energy density of the two above components, together with measuring the Hubble constant that determines the age of the Universe, is a major goal of modern astrophysics. An interesting method for estimating these parameters is strong gravitational lensing of quasars (QSOs). As shown......One of the most intriguing recent results in physics is the growing evidence that an unknown energy field and an unknown kind of matter are the major components of the Universe (70% and 30%, respectively; see e.g. Riess et al. 1998, Spergel et al. 2007). Understanding and estimating the precise...... by Refsdal (1964), H0, !m and !! can be measured based on the time delay ("t) between multiply lensed images of QSOs, because "t depends on H0 and on the distances to lens and source, hence!m and !!. Determination of cosmological parameters using gravitational lensing suffers from some degeneracies...

  9. Electron lenses for super-colliders

    CERN Document Server

    Shiltsev, Vladimir D

    2016-01-01

    This book provides a comprehensive overview of the operating principles and technology of electron lenses in supercolliders.  Electron lenses are a novel instrument for high energy particle accelerators, particularly for the energy-frontier superconducting hadron colliders, including the Tevatron, RHIC, LHC and future very large hadron colliders.  After reviewing the issues surrounding beam dynamics in supercolliders, the book offers an introduction to the electron lens method and its application.  Further chapters describe the technology behind the electron lenses which have recently been proposed, built and employed for compensation of beam-beam effects and for collimation of high-energy high-intensity beams, for compensation of space-charge effects and several other applications in accelerators. The book will be an invaluable resource for those involved in the design, construction and operation of the next generation of hadron colliders.

  10. Gravitational Lensing Signatures of Long Cosmic Strings

    CERN Document Server

    De Laix, A A; Vachaspati, T; Laix, Andrew A. de; Krauss, Lawrence M.; Vachaspati, Tanmay

    1997-01-01

    The gravitational lensing by long, wiggly cosmic strings is shown to produce a large number of lensed images of a background source. In addition to pairs of images on either side of the string, a number of small images outline the string due to small-scale structure on the string. This image pattern could provide a highly distinctive signature of cosmic strings. Since the optical depth for multiple imaging of distant quasar sources by long strings may be comparable to that by galaxies, these image patterns should be clearly observable in the next generation of redshift surveys such as the Sloan Digital Sky Survey.

  11. Achromatic Cooling Channel with Li Lenses

    Energy Technology Data Exchange (ETDEWEB)

    Balbekov, V. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2002-04-29

    A linear cooling channel with Li lenses, solenoids, and 201 MHz RF cavities is considered. A special lattice design is used to minimize chromatic aberrations by suppression of several betatron resonances. Transverse emittance of muon beam decreases from 2 mm to 0.5 mm at the channel of about 110 m length. Longitudinal heating is modest, therefore transmission of the channel is rather high: 96% without decay and 90% with decay. Minimal beam emittance achievable by similar channel estimated as about 0.25 mm at surface field of Li lenses 10 T.

  12. Rigid gas permeable lenses and patient management.

    Science.gov (United States)

    Terry, R; Schnider, C; Holden, B A

    1989-01-01

    The introduction of new rigid gas permeable (RGP) contact lens materials provides the practitioner with a number of alternatives for patient management. But whatever the lens materials used, problems related to the lenses, care and maintenance solutions, and patients may arise. This paper examines concerns such as parameter instability, durability of lenses, compatibility of materials and solutions, patient education and compliance, 3 and 9 o'clock staining, corneal distortion, and lid changes. Suggestions are made on ways to avoid or minimize problems related to RGP lens wear.

  13. Modern scleral contact lenses : a review

    OpenAIRE

    van der Worp, Eef; Bornman, Dina; Ferreira, Daniela Lopes; Ribeiro, Miguel Faria; Garcia-Porta, Nery; González-Méijome, José Manuel

    2014-01-01

    Scleral contact lenses (ScCL) have gained renewed interest during the last decade. Originally, they wereprimarily used for severely compromised eyes. Corneal ectasia and exposure conditions were the primaryindications. However, the indication range of ScCL in contact lens practices seems to be expanding, andit now increasingly includes less severe and even non-compromised eyes, too.All lenses that partly or entirely rest on the sclera are included under the name ScCL in this paper;although th...

  14. High-speed optical signal processing using time lenses

    DEFF Research Database (Denmark)

    Galili, Michael; Hu, Hao; Guan, Pengyu

    2015-01-01

    This paper will discuss time lenses and their broad range of applications. A number of recent demonstrations of complex high-speed optical signal processing using time lenses will be outlined with focus on the operating principle.......This paper will discuss time lenses and their broad range of applications. A number of recent demonstrations of complex high-speed optical signal processing using time lenses will be outlined with focus on the operating principle....

  15. Stacked Weak Lensing Mass Calibration: Estimators, Systematics, and Impact on Cosmological Parameter Constraints

    Energy Technology Data Exchange (ETDEWEB)

    Rozo, Eduardo; /U. Chicago /Chicago U., KICP; Wu, Hao-Yi; /KIPAC, Menlo Park; Schmidt, Fabian; /Caltech

    2011-11-04

    When extracting the weak lensing shear signal, one may employ either locally normalized or globally normalized shear estimators. The former is the standard approach when estimating cluster masses, while the latter is the more common method among peak finding efforts. While both approaches have identical signal-to-noise in the weak lensing limit, it is possible that higher order corrections or systematic considerations make one estimator preferable over the other. In this paper, we consider the efficacy of both estimators within the context of stacked weak lensing mass estimation in the Dark Energy Survey (DES). We find that the two estimators have nearly identical statistical precision, even after including higher order corrections, but that these corrections must be incorporated into the analysis to avoid observationally relevant biases in the recovered masses. We also demonstrate that finite bin-width effects may be significant if not properly accounted for, and that the two estimators exhibit different systematics, particularly with respect to contamination of the source catalog by foreground galaxies. Thus, the two estimators may be employed as a systematic cross-check of each other. Stacked weak lensing in the DES should allow for the mean mass of galaxy clusters to be calibrated to {approx}2% precision (statistical only), which can improve the figure of merit of the DES cluster abundance experiment by a factor of {approx}3 relative to the self-calibration expectation. A companion paper investigates how the two types of estimators considered here impact weak lensing peak finding efforts.

  16. Controlled Release of Antibiotics From Vitamin E-Loaded Silicone-Hydrogel Contact Lenses.

    Science.gov (United States)

    Paradiso, Patrizia; Serro, Ana Paula; Saramago, Benilde; Colaço, Rogério; Chauhan, Anuj

    2016-03-01

    Symptoms of bacterial and fungal keratitis are typically treated through the frequent application of antibiotic and antifungal eye drops. The high frequency of half hourly or hourly eye drop administration required to treat these indications is tedious and could reduce compliance. Here, we combine in vitro experiments with a mathematical model to develop therapeutic soft contact lenses to cure keratitis by extended release of suitable drugs. We specifically focus on increasing the release duration of levofloxacin and chlorhexidine from 1-DAY ACUVUE(®) TrueEye™ and ACUVUE OASYS(®) contact lenses by incorporating vitamin E diffusion barriers. Results show that 20% of vitamin E loading in the contact lens increases the release duration of levofloxacin to 100 h and 50 h from 1-DAY ACUVUE(®) TrueEye™ and ACUVUE OASYS(®), respectively, which is a 3- and 6-fold increase, respectively, for the 2 lenses. For chlorhexidine, the increase is 2.5- and 10-fold, for the TrueEye™ and OASYS(®), respectively, to 130 h and 170 h. The mass of drug loaded in the lenses can be controlled to achieve a daily release comparable to the commonly prescribed eye drop therapy. The vitamin E-loaded lenses retain all critical properties for in vivo use. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  17. Planck intermediate results XLI. A map of lensing-induced B-modes

    DEFF Research Database (Denmark)

    Ade, P. A. R.; Aghanim, N.; Ashdown, M.

    2016-01-01

    to 2000. In particular, when cross-correlating with the B-mode contribution directly derived from the Planck polarization maps, we obtain lensing-induced B-mode power spectrum measurement at a significance level of 12 sigma, which agrees with the theoretical expectation derived from the Planck best-fit....... It will be particularly useful for experiments searching for primordial B-modes, such as BICEP2/Keck Array or LiteBIRD, since it will enable an estimate to be made of the lensing-induced contribution to the measured total CMB B-modes....

  18. OGLE-2017-BLG-0173Lb: Low-mass-ratio Planet in a “Hollywood” Microlensing Event

    Science.gov (United States)

    Hwang, K.-H.; Udalski, A.; Shvartzvald, Y.; Ryu, Y.-H.; Albrow, M. D.; Chung, S.-J.; Gould, A.; Han, C.; Jung, Y. K.; Shin, I.-G.; Yee, J. C.; Zhu, W.; Cha, S.-M.; Kim, D.-J.; Kim, H.-W.; Kim, S.-L.; Lee, C.-U.; Lee, D.-J.; Lee, Y.; Park, B.-G.; Pogge, R. W.; KMTNet Collaboration; Skowron, J.; Mróz, P.; Poleski, R.; Kozłowski, S.; Soszyński, I.; Pietrukowicz, P.; Szymański, M. K.; Ulaczyk, K.; Pawlak, M.; OGLE Collaboration; Bryden, G.; Beichman, C.; Calchi Novati, S.; Gaudi, B. S.; Henderson, C. B.; Jacklin, S.; Penny, M. T.; UKIRT Microlensing Team

    2018-01-01

    We present microlensing planet OGLE-2017-BLG-0173Lb, with planet–host mass ratio of either q≃ 2.5× {10}-5 or q≃ 6.5× {10}-5, the lowest or among the lowest ever detected. The planetary perturbation is strongly detected, Δχ 2 ∼ 10000, because it arises from a bright (therefore, large) source passing over and enveloping the planetary caustic: a so-called “Hollywood” event. The factor ∼2.5 offset in q arises because of a previously unrecognized discrete degeneracy between Hollywood events in which the caustic is fully enveloped and those in which only one flank is enveloped, which we dub “Cannae” and “von Schlieffen,” respectively. This degeneracy is “accidental” in that it arises from gaps in the data. Nevertheless, the fact that it appears in a Δχ 2 = 10000 planetary anomaly is striking. We present a simple formalism to estimate the sensitivity of other Hollywood events to planets and show that they can lead to detections close to, but perhaps not quite reaching, the Earth/Sun mass ratio of 3× {10}-6. This formalism also enables an analytic understanding of the factor ∼2.5 offset in q between the Cannae and von Schlieffen solutions. The Bayesian estimates for the host mass, system distance, and planet–host projected separation are M={0.39}-0.24+0.40 {M}ȯ , {D}L={4.8}-1.8+1.5 {kpc}, and {a}\\perp =3.8+/- 1.6 {au}, respectively. The two estimates of the planet mass are {m}p={3.3}-2.1+3.8 {M}\\oplus and {m}p={8}-6+11 {M}\\oplus . The measured lens-source relative proper motion μ =6 {mas} {{yr}}-1 will permit imaging of the lens in about 15 years or at first light on adaptive-optics imagers on next-generation telescopes. These will allow one to measure the host mass but probably will not be able to resolve the planet–host mass-ratio degeneracy.

  19. A POSSIBLE BINARY SYSTEM OF A STELLAR REMNANT IN THE HIGH-MAGNIFICATION GRAVITATIONAL MICROLENSING EVENT OGLE-2007-BLG-514

    Energy Technology Data Exchange (ETDEWEB)

    Miyake, N.; Abe, F.; Furusawa, K.; Itow, Y. [Solar-Terrestrial Environment Laboratory, Nagoya University, Nagoya 464-8601 (Japan); Udalski, A.; Kubiak, M.; Szymanski, M. K.; Pietrzynski, G.; Soszynski, I.; Ulaczyk, K.; Wyrzykowski, L. [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland); Sumi, T. [Department of Earth and Space Science, Osaka University, Osaka 560-0043 (Japan); Bennett, D. P. [Department of Physics, University of Notre Dame, 225 Nieuwland Science Hall, Notre Dame, IN 46556 (United States); Dong, S.; Gould, A. [Department of Astronomy, Ohio State University, 140 West 18th Avenue, Columbus, OH 43210 (United States); Street, R. A. [Las Cumbres Observatory, 6740B Cortona Drive, Suite 102, Goleta, CA 93117 (United States); Greenhill, J. [School of Maths and Physics, University of Tasmania, Private bag 37, GPO Hobart, Tasmania 7001 (Australia); Bond, I. A. [Institute for Information and Mathematical Sciences, Massey University, Private Bag 102-904, Auckland 1330 (New Zealand); Fukui, A. [Okayama Astrophysical Observatory, National Astronomical Observatory of Japan, Okayama 719-0232 (Japan); Holderness, S., E-mail: nmiyake@stelab.nagoya-u.ac.jp [Computer Science Department, University of Auckland, Auckland (New Zealand); Collaboration: OGLE Collaboration; MOA Collaboration; muFUN Collaboration; RoboNet Collaboration; PLANET Collaboration; and others

    2012-06-20

    We report the extremely high-magnification (A > 1000) binary microlensing event OGLE-2007-BLG-514. We obtained good coverage around the double peak structure in the light curve via follow-up observations from different observatories. The binary lens model that includes the effects of parallax (known orbital motion of the Earth) and orbital motion of the lens yields a binary lens mass ratio of q = 0.321 {+-} 0.007 and a projected separation of s = 0.072 {+-} 0.001 in units of the Einstein radius. The parallax parameters allow us to determine the lens distance D{sub L} = 3.11 {+-} 0.39 kpc and total mass M{sub L} = 1.40 {+-} 0.18 M{sub Sun }; this leads to the primary and secondary components having masses of M{sub 1} = 1.06 {+-} 0.13 M{sub Sun} and M{sub 2} = 0.34 {+-} 0.04 M{sub Sun }, respectively. The parallax model indicates that the binary lens system is likely constructed by the main-sequence stars. On the other hand, we used a Bayesian analysis to estimate probability distributions by the model that includes the effects of xallarap (possible orbital motion of the source around a companion) and parallax (q = 0.270 {+-} 0.005, s = 0.083 {+-} 0.001). The primary component of the binary lens is relatively massive, with M{sub 1} = 0.9{sup +4.6}{sub -0.3} M{sub Sun} and it is at a distance of D{sub L} = 2.6{sup +3.8}{sub -0.9} kpc. Given the secure mass ratio measurement, the companion mass is therefore M{sub 2} = 0.2{sup +1.2}{sub -0.1} M{sub Sun }. The xallarap model implies that the primary lens is likely a stellar remnant, such as a white dwarf, a neutron star, or a black hole.

  20. Analysis of luminosity distributions of strong lensing galaxies: subtraction of diffuse lensed signal

    Science.gov (United States)

    Biernaux, J.; Magain, P.; Hauret, C.

    2017-08-01

    Context. Strong gravitational lensing gives access to the total mass distribution of galaxies. It can unveil a great deal of information about the lenses' dark matter content when combined with the study of the lenses' light profile. However, gravitational lensing galaxies, by definition, appear surrounded by lensed signal, both point-like and diffuse, that is irrelevant to the lens flux. Therefore, the observer is most often restricted to studying the innermost portions of the galaxy, where classical fitting methods show some instabilities. Aims: We aim at subtracting that lensed signal and at characterising some lenses' light profile by computing their shape parameters (half-light radius, ellipticity, and position angle). Our objective is to evaluate the total integrated flux in an aperture the size of the Einstein ring in order to obtain a robust estimate of the quantity of ordinary (luminous) matter in each system. Methods: We are expanding the work we started in a previous paper that consisted in subtracting point-like lensed images and in independently measuring each shape parameter. We improve it by designing a subtraction of the diffuse lensed signal, based only on one simple hypothesis of symmetry. We apply it to the cases where it proves to be necessary. This extra step improves our study of the shape parameters and we refine it even more by upgrading our half-light radius measurement method. We also calculate the impact of our specific image processing on the error bars. Results: The diffuse lensed signal subtraction makes it possible to study a larger portion of relevant galactic flux, as the radius of the fitting region increases by on average 17%. We retrieve new half-light radii values that are on average 11% smaller than in our previous work, although the uncertainties overlap in most cases. This shows that not taking the diffuse lensed signal into account may lead to a significant overestimate of the half-light radius. We are also able to measure

  1. Coatings and Tints of Spectacle Lenses

    Directory of Open Access Journals (Sweden)

    H. Zeki Büyükyıldız

    2012-10-01

    Full Text Available Spectacle lenses are made of mineral or organic (plastic materials. Various coatings and tints are applied to the spectacle lenses according to the characteristic of the lens material, and for the personal needs and cosmetic purpose. The coatings may be classified in seven groups: 1 Anti-reflection coatings, 2 Hard coatings, 3 Clean coat, 4 Mirror coatings, 5 Color tint coating (one of coloring processes, 6 Photochromic coating (one of photochromic processes, and 7 Anti-fog coatings. Anti-reflection coatings reduce unwanted reflections from the lens surfaces and increase light transmission. Hard coatings are applied for preventing the plastic lens surface from scratches and abrasion. Hard coatings are not required for the mineral lenses due to their hardness. Clean coat makes the lens surface smooth and hydrophobic. Thus, it prevents the adherence of dust, tarnish, and dirt particles on the lens surface. Mirror coatings are applied onto the sunglasses for cosmetic purpose. Color tinted and photochromic lenses are used for sun protection and absorption of the harmful UV radiations. Anti-fog coatings make the lens surface hydrophilic and prevent the coalescence of tiny water droplets on the lens surface that reduces light transmission. (Turk J Ophthalmol 2012; 42: 359-69

  2. Optical aberrations in a gas lenses

    CSIR Research Space (South Africa)

    Mafusire, C

    2010-08-01

    Full Text Available Gas lenses work on the basis that aerodynamic media can be used to generate a graded refractive index distribution which can be used to focus a laser beam. Examples of these are the spinning pipe gas lens (SPGL) and the flame lens (FL). The SPGL...

  3. GRAVITATIONAL LENSES AND UNCONVENTIONAL GRAVITY THEORIES

    NARCIS (Netherlands)

    BEKENSTEIN, JD; SANDERS, RH

    1994-01-01

    We study gravitational lensing by clusters of galaxies in the context of the generic class of unconventional gravity theories which describe gravity in terms of a metric and one or more scalar fields (called here scalar-tensor theories). We conclude that, if the scalar fields have positive energy,

  4. Modern scleral lenses part II: patient satisfaction.

    NARCIS (Netherlands)

    Visser, E.S.; Visser, R.; Lier, H.J.J. van; Otten, H.M.

    2007-01-01

    PURPOSE: To evaluate the subjective performance of modern scleral lenses in patients of the clinics of Visser Contact Lens Practice. METHODS: In this cross-sectional survey, all the necessary data were collected at the first follow-up visit during the 5-month study period. In accordance with the

  5. Studying dark matter haloes with weak lensing

    NARCIS (Netherlands)

    Velander, Malin Barbro Margareta

    2012-01-01

    Our Universe is comprised not only of normal matter but also of unknown components: dark matter and dark energy. This Thesis recounts studies of dark matter haloes, using a technique known as weak gravitational lensing, in order to learn more about the nature of these dark components. The haloes

  6. Quantum Spin Lenses in Atomic Arrays

    Directory of Open Access Journals (Sweden)

    A. W. Glaetzle

    2017-09-01

    Full Text Available We propose and discuss quantum spin lenses, where quantum states of delocalized spin excitations in an atomic medium are focused in space in a coherent quantum process down to (essentially single atoms. These can be employed to create controlled interactions in a quantum light-matter interface, where photonic qubits stored in an atomic ensemble are mapped to a quantum register represented by single atoms. We propose Hamiltonians for quantum spin lenses as inhomogeneous spin models on lattices, which can be realized with Rydberg atoms in 1D, 2D, and 3D, and with strings of trapped ions. We discuss both linear and nonlinear quantum spin lenses: in a nonlinear lens, repulsive spin-spin interactions lead to focusing dynamics conditional to the number of spin excitations. This allows the mapping of quantum superpositions of delocalized spin excitations to superpositions of spatial spin patterns, which can be addressed by light fields and manipulated. Finally, we propose multifocal quantum spin lenses as a way to generate and distribute entanglement between distant atoms in an atomic lattice array.

  7. Bias to CMB lensing reconstruction from temperature anisotropies due to large-scale galaxy motions

    Science.gov (United States)

    Ferraro, Simone; Hill, J. Colin

    2018-01-01

    Gravitational lensing of the cosmic microwave background (CMB) is expected to be amongst the most powerful cosmological tools for ongoing and upcoming CMB experiments. In this work, we investigate a bias to CMB lensing reconstruction from temperature anisotropies due to the kinematic Sunyaev-Zel'dovich (kSZ) effect, that is, the Doppler shift of CMB photons induced by Compton scattering off moving electrons. The kSZ signal yields biases due to both its own intrinsic non-Gaussianity and its nonzero cross-correlation with the CMB lensing field (and other fields that trace the large-scale structure). This kSZ-induced bias affects both the CMB lensing autopower spectrum and its cross-correlation with low-redshift tracers. Furthermore, it cannot be removed by multifrequency foreground separation techniques because the kSZ effect preserves the blackbody spectrum of the CMB. While statistically negligible for current data sets, we show that it will be important for upcoming surveys, and failure to account for it can lead to large biases in constraints on neutrino masses or the properties of dark energy. For a stage 4 CMB experiment, the bias can be as large as ≈15 % or 12% in cross-correlation with LSST galaxy lensing convergence or galaxy overdensity maps, respectively, when the maximum temperature multipole used in the reconstruction is ℓmax=4000 , and about half of that when ℓmax=3000 . Similarly, we find that the CMB lensing autopower spectrum can be biased by up to several percent. These biases are many times larger than the expected statistical errors. We validate our analytical predictions with cosmological simulations and present the first complete estimate of secondary-induced CMB lensing biases. The predicted bias is sensitive to the small-scale gas distribution, which is affected by pressure and feedback mechanisms, thus making removal via "bias-hardened" estimators challenging. Reducing ℓmax can significantly mitigate the bias at the cost of a decrease

  8. The nature of parallax microlensing events towards the Galactic bulge

    NARCIS (Netherlands)

    Smith, MC; Belokurov, [No Value; Evans, NW; Mao, SD; An, JH

    2005-01-01

    Perhaps as many as 30 parallax microlensing events are known, thanks to the efforts of the Massive Compact Halo Object (MACHO), Optical Gravitational Lensing Experiment (OGLE), Experience pour la Recherche d'Objets Sombres (EROS) and Microlensing Observations in Astrophysics (MOA) experiments

  9. Processes for manufacturing multifocal diffractive-refractive intraocular lenses

    Science.gov (United States)

    Iskakov, I. A.

    2017-09-01

    Manufacturing methods and design features of modern diffractive-refractive intraocular lenses are discussed. The implantation of multifocal intraocular lenses is the most optimal method of restoring the accommodative ability of the eye after removal of the natural lens. Diffractive-refractive intraocular lenses are the most widely used implantable multifocal lenses worldwide. Existing methods for manufacturing such lenses implement various design solutions to provide the best vision function after surgery. The wide variety of available diffractive-refractive intraocular lens designs reflects the demand for this method of vision correction in clinical practice and the importance of further applied research and development of new technologies for designing improved lens models.

  10. Gaia eclipsing binary and multiple systems. Two-Gaussian models applied to OGLE-III eclipsing binary light curves in the Large Magellanic Cloud

    Science.gov (United States)

    Mowlavi, N.; Lecoeur-Taïbi, I.; Holl, B.; Rimoldini, L.; Barblan, F.; Prša, A.; Kochoska, A.; Süveges, M.; Eyer, L.; Nienartowicz, K.; Jevardat, G.; Charnas, J.; Guy, L.; Audard, M.

    2017-10-01

    Context. The advent of large scale multi-epoch surveys raises the need for automated light curve (LC) processing. This is particularly true for eclipsing binaries (EBs), which form one of the most populated types of variable objects. The Gaia mission, launched at the end of 2013, is expected to detect of the order of few million EBs over a five-year mission. Aims: We present an automated procedure to characterize EBs based on the geometric morphology of their LCs with two aims: first to study an ensemble of EBs on a statistical ground without the need to model the binary system, and second to enable the automated identification of EBs that display atypical LCs. Methods: We modeled the folded LC geometry of EBs using up to two Gaussian functions for the eclipses and a cosine function for any ellipsoidal-like variability that may be present between the eclipses. The procedure is applied to the OGLE-III data set of EBs in the Large Magellanic Cloud (LMC) as a proof of concept. The Bayesian information criterion is used to select the best model among models containing various combinations of those components, as well as to estimate the significance of the components. Results: Based on the two-Gaussian models, EBs with atypical LC geometries are successfully identified in two diagrams, using the Abbe values of the original and residual folded LCs, and the reduced χ2. Cleaning the data set from the atypical cases and further filtering out LCs that contain non-significant eclipse candidates, the ensemble of EBs can be studied on a statistical ground using the two-Gaussian model parameters. For illustrative purposes, we present the distribution of projected eccentricities as a function of orbital period for the OGLE-III set of EBs in the LMC, as well as the distribution of their primary versus secondary eclipse widths. The two-Gaussian models for all the OGLE-III LMC EBs table is only available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (http://130

  11. [A girl with dyslexia suspected to have Irlen syndrome, completely relieved by wearing tinted lenses].

    Science.gov (United States)

    Kusano, Yusuke; Awaya, Tomonari; Saito, Keiko; Yoshida, Takeshi; Ide, Minako; Kato, Takeo; Heike, Toshio; Kato, Toshihiro

    2015-11-01

    Irlen syndrome is a proposed perceptual processing disorder characterized by visual distortions while reading. Patients with this syndrome may experience light sensitivity, visual stress, and other related problems such as dyslexia. Tinted lenses and colored overlays have been designed to help individuals with the symptoms of Irlen syndrome. However, there is still debate over the effectiveness of these interventions and whether this syndrome actually exists. In this report, we describe a case involving an 8-year-old girl with dyslexia who experienced severe visual hypersensitivity and whose symptoms completely resolved after wearing tinted lenses. While it is possible that she experienced a psychogenic visual disturbance that was relieved because of the placebo effect, the clinical course of her symptoms matched the findings previously described by Irlen. The patient was unable to read without tinted lenses. With tinted lenses, she could read at the appropriate age level, suggesting that her difficulty was due to a problem in optical information processing. The concepts underlying Irlen syndrome are vaguely defined, and several groups insist that the visual stress associated with this syndrome might be responsible for dyslexia as well as other disorders. These ambiguous criteria may be responsible for the criticism over the validity of this condition. Although this was only an anecdotal case, our patient exhibited the core functional deficit described in Irlen syndrome and showed a dramatic improvement with tinted lenses; therefore, this case may facilitate investigations into the mechanism underlying Irlen syndrome, if it actually exists. Although further studies are required to confirm the validity of this syndrome and the treatment approach, Irlen syndrome should be recognized as a disorder since its symptoms can be easily relieved by wearing tinted lenses or color filters.

  12. Calibration of fisheye lenses for hemispherical photography

    International Nuclear Information System (INIS)

    Diaci, J.; Kolar, U.

    2000-01-01

    Hemispherical photography represents one of the most appropriate methods of estimating averages of solar radiation over extended periods of time. This method is based upon the use of extremely wide-angle fisheye lenses, which produce large projection distortion. To correctly interpret hemispherical photography we have to know the projection characteristics of the fisheye lens in combination with a camera body. This can be achieved through lens calibration. The first part of the article explains in detail the calibration method for fisheye lenses which are used to assess the solar radiation in forest ecology research. In the second part the results of calibration for fisheye lens Sigma 8 mm, f/4 (MF, N) are presented. The lens was used on a Nikon F50 camera body

  13. Astrophysical observations: lensing and eclipsing Einstein's theories.

    Science.gov (United States)

    Bennett, Charles L

    2005-02-11

    Albert Einstein postulated the equivalence of energy and mass, developed the theory of special relativity, explained the photoelectric effect, and described Brownian motion in five papers, all published in 1905, 100 years ago. With these papers, Einstein provided the framework for understanding modern astrophysical phenomena. Conversely, astrophysical observations provide one of the most effective means for testing Einstein's theories. Here, I review astrophysical advances precipitated by Einstein's insights, including gravitational redshifts, gravitational lensing, gravitational waves, the Lense-Thirring effect, and modern cosmology. A complete understanding of cosmology, from the earliest moments to the ultimate fate of the universe, will require developments in physics beyond Einstein, to a unified theory of gravity and quantum physics.

  14. Microfabrication of hard x-ray lenses

    DEFF Research Database (Denmark)

    Stöhr, Frederik

    This thesis deals with the development of silicon compound refractive lenses (Si-CRLs) for shaping hard x-ray beams. The CRLs are to be fabricated using state of the art microfabrication techniques. The primary goal of the thesis work is to produce Si-CRLs with considerably increased structure...... intense and wider line beams with narrower waists. The thesis starts with a review of alternative x-ray lenses. Si-CRLs are identified as valuable optical components that allow shaping hard x-rays efficiently and creating beam waists that are clearly in the nanometer range. They stand out...... and characterized with respect to their shape. Their optical performances were tested at the European Synchrotron Radiation Facility (ESRF). Two 1D-focusing Si-CRLs suitable as condensers in hard-XRM were developed utilizing the aforementioned two different strategies. The first Si-condenser showed focusing of a 56...

  15. Design considerations for liquid crystal contact lenses

    Science.gov (United States)

    Bailey, J.; Kaur, S.; Morgan, P. B.; Gleeson, H. F.; Clamp, J. H.; Jones, J. C.

    2017-12-01

    Switchable liquid crystal contact lenses with electrically controllable focal powers have previously been investigated as an alternative to bifocal contact lenses and spectacles for the correction of presbyopia. The simplest lens design uses a meniscus shaped cavity within the lens to contain the liquid crystal. The design of such a lens is considered in detail, including the nematic alignment and electrodes materials. The organic transparent conductor PEDOT:PSS was used as both electrode and planar alignment. Four different configurations are considered, using both planar and homeotropic orientations with either homogenous or axial alignment. Controllable switching of the focal power was demonstrated for each mode and focal power changes of up to ΔP  =  3.3  ±  0.2 D achieved. Such lens designs offer significant potential for a novel form of correction for this common visual problem.

  16. Irregular Corneas: Improve Visual Function With Scleral Contact Lenses.

    Science.gov (United States)

    de Luis Eguileor, Beatriz; Etxebarria Ecenarro, Jaime; Santamaria Carro, Alaitz; Feijoo Lera, Raquel

    2016-10-20

    To assess visual function in patients with irregular cornea who do not tolerate gas permeable (GP) corneal contact lenses and are fitted with GP scleral contact lenses (Rose K2 XL). In this prospective study, we analyzed 15 eyes of 15 patients who did not tolerate GP corneal contact lenses and were fitted with scleral contact lenses (Rose K2 XL). We assessed visual function using visual acuity and the visual function index (VF-14); we used the VF-14 as an indicator of patient satisfaction. The measurements were taken with the optical correction used before and 1 month after the fitting of the Rose K2 XL contact lenses. We also recorded the number of hours lenses had been worn over the first month. Using Rose K2 XL contact lenses, visual acuity was 0.06±0.07 logMAR. In all cases, visual acuity had improved compared with the measurement before fitting the lenses (0.31±0.18 logMAR; P=0.001). VF-14 scores were 72.74±12.38 before fitting of the scleral lenses, and 89.31±10.87 after 1 month of lens use (P=0.003). Patients used these scleral lenses for 9.33±2.99 comfortable hours of wear. Both visual acuity and VF-14 may improve after fitting Rose K2 XL contact lenses in patients with irregular corneas. In addition, in our patients, these lenses can be worn for a longer period than GP corneal contact lenses.

  17. Fitting gravitational lenses: truth or delusion

    Science.gov (United States)

    Evans, N. Wyn; Witt, Hans J.

    2003-11-01

    The observables in a strong gravitational lens are usually just the image positions and sometimes the flux ratios. We develop a new and simple algorithm which allows a set of models to be fitted exactly to the observations. Taking our cue from the strong body of evidence that early-type galaxies are close to isothermal, we assume that the lens is scale-free with a flat rotation curve. External shear can be easily included. Our algorithm allows full flexibility regarding the angular structure of the lensing potential. Importantly, all the free parameters enter linearly into the model and so the lens and flux ratio equations can always be solved by straightforward matrix inversion. The models are only restricted by the fact that the surface mass density must be positive. We use this new algorithm to examine some of the claims made for anomalous flux ratios. It has been argued that such anomalies betray the presence of substantial amounts of substructure in the lensing galaxy. We demonstrate by explicit construction that some of the lens systems for which substructure has been claimed can be well fitted by smooth lens models. This is especially the case when the systematic errors in the flux ratios (caused by microlensing or differential extinction) are taken into account. However, there is certainly one system (B1422+231) for which the existing smooth models are definitely inadequate and for which substructure may be implicated. Within a few tens of kpc of the lensing galaxy centre, dynamical friction and tidal disruption are known to be very efficient at dissolving any substructure. Very little substructure is projected within the Einstein radius. The numbers of strong lenses for which substructure is currently being claimed may be so large that this contradicts rather than supports cold dark matter theories.

  18. Gravitational lensing by a Horndeski black hole

    Energy Technology Data Exchange (ETDEWEB)

    Badia, Javier [Instituto de Astronomia y Fisica del Espacio (IAFE, CONICET-UBA), Buenos Aires (Argentina); Eiroa, Ernesto F. [Instituto de Astronomia y Fisica del Espacio (IAFE, CONICET-UBA), Buenos Aires (Argentina); Universidad de Buenos Aires, Ciudad Universitaria Pabellon I, Departamento de Fisica, Facultad de Ciencias Exactas y Naturales, Buenos Aires (Argentina)

    2017-11-15

    In this article we study gravitational lensing by non-rotating and asymptotically flat black holes in Horndeski theory. By adopting the strong deflection limit, we calculate the deflection angle, from which we obtain the positions and the magnifications of the relativistic images. We compare our results with those corresponding to black holes in General Relativity. We analyze the astrophysical consequences in the case of the nearest supermassive black holes. (orig.)

  19. Gravitational lensing of the SNLS supernovae

    International Nuclear Information System (INIS)

    Kronborg, T.

    2011-01-01

    Type Ia supernovae have become an essential tool of modern observational cosmology. By studying the distance-redshift relation of a large number of supernovae, the nature of dark energy can be unveiled. Distances to Type Ia SNe are however affected by gravitational lensing which can induce systematic effects in the measurement of cosmology. The majority of the supernovae is slightly de-magnified whereas a small fraction is significantly magnified due to the mass distribution along the line of sight. This causes naturally an additional dispersion in the observed magnitudes. There are two different ways to estimate the magnification of a supernova. A first method consists in comparing the supernova luminosity, which is measured to about 15% precision, to the mean SN luminosity at the same redshift. Another estimate can be obtained from predicting the magnification induced by the foreground matter density modeled from the measurements of the luminosity of the galaxies with an initial prior on the mass-luminosity relation of the galaxies. A correlation between these 2 estimates will make it possible to tune the initially used mass-luminosity relation resulting in an independent measurement of the dark matter clustering based on the luminosity of SNe Ia. Evidently, this measurement depends crucially on the detection of this correlation also referred to as the lensing signal. This thesis is dedicated to the measurement of the lensing signal in the SNLS 3-year sample. (author)

  20. Personal radon dosimetry from eyeglass lenses

    Energy Technology Data Exchange (ETDEWEB)

    Fleischer, R.L.; Meyer, N.R.; Hadley, S.A.; MacDonald, J.; Cavallo, A

    2001-07-01

    Eyeglass lenses are commonly composed of allyl-diglycol carbonate (CR-39), an alpha-particle detecting plastic, thus making such lenses personal radon dosemeters. Samples of such lenses have been obtained, etched to reveal that radon and radon progeny alpha tracks can be seen in abundance, and sensitivities have been calibrated in radon chambers as a primary calibration, and with a uranium-based source of alpha particles as a convenient secondary standard. With one exception natural, environmental (fossil) track densities ranged from less than 3,000 to nearly 70,000 per cm{sup 2} for eyeglasses that had been worn for various times from one to nearly five years. Average radon concentrations to which those wearers were exposed are inferred to be in the range 14 to 130 Bq.m{sup -3} (0.4 to 3.5 pCi.l{sup -1}). A protocol for consistent, meaningful readout is derived and used. In the exceptional case the fossil track density was 1,780,000 cm{sup -2}, and the inferred (24 h) average radon concentration was 6500 Bq.m{sup -3} (175 pCi.l{sup -1}) for a worker at an inactive uranium mine that is used for therapy. (author)

  1. Automation Enhancement of Multilayer Laue Lenses

    Energy Technology Data Exchange (ETDEWEB)

    Lauer K. R.; Conley R.

    2010-12-01

    X-ray optics fabrication at Brookhaven National Laboratory has been facilitated by a new, state of the art magnetron sputtering physical deposition system. With its nine magnetron sputtering cathodes and substrate carrier that moves on a linear rail via a UHV brushless linear servo motor, the system is capable of accurately depositing the many thousands of layers necessary for multilayer Laue lenses. I have engineered a versatile and automated control program from scratch for the base system and many subsystems. Its main features include a custom scripting language, a fully customizable graphical user interface, wireless and remote control, and a terminal-based interface. This control system has already been successfully used in the creation of many types of x-ray optics, including several thousand layer multilayer Laue lenses.Before reaching the point at which a deposition can be run, stencil-like masks for the sputtering cathodes must be created to ensure the proper distribution of sputtered atoms. Quality of multilayer Laue lenses can also be difficult to measure, given the size of the thin film layers. I employ my knowledge of software and algorithms to further ease these previously painstaking processes with custom programs. Additionally, I will give an overview of an x-ray optic simulator package I helped develop during the summer of 2010. In the interest of keeping my software free and open, I have worked mostly with the multiplatform Python and the PyQt application framework, utilizing C and C++ where necessary.

  2. Galaxy–Galaxy Weak-lensing Measurements from SDSS. I. Image Processing and Lensing Signals

    International Nuclear Information System (INIS)

    Luo, Wentao; Yang, Xiaohu; Zhang, Jun; Tweed, Dylan; Fu, Liping; Shu, Chenggang; Mo, H. J.; Bosch, Frank C. van den; Li, Ran; Li, Nan; Liu, Xiangkun; Pan, Chuzhong; Wang, Yiran; Radovich, Mario

    2017-01-01

    We present our image processing pipeline that corrects the systematics introduced by the point-spread function (PSF). Using this pipeline, we processed Sloan Digital Sky Survey (SDSS) DR7 imaging data in r band and generated a galaxy catalog containing the shape information. Based on our shape measurements of the galaxy images from SDSS DR7, we extract the galaxy–galaxy (GG) lensing signals around foreground spectroscopic galaxies binned in different luminosities and stellar masses. We estimated the systematics, e.g., selection bias, PSF reconstruction bias, PSF dilution bias, shear responsivity bias, and noise rectification bias, which in total is between −9.1% and 20.8% at 2 σ levels. The overall GG lensing signals we measured are in good agreement with Mandelbaum et al. The reduced χ 2 between the two measurements in different luminosity bins are from 0.43 to 0.83. Larger reduced χ 2 from 0.60 to 1.87 are seen for different stellar mass bins, which is mainly caused by the different stellar mass estimator. The results in this paper with higher signal-to-noise ratio are due to the larger survey area than SDSS DR4, confirming that more luminous/massive galaxies bear stronger GG lensing signals. We divide the foreground galaxies into red/blue and star-forming/quenched subsamples and measure their GG lensing signals. We find that, at a specific stellar mass/luminosity, the red/quenched galaxies have stronger GG lensing signals than their counterparts, especially at large radii. These GG lensing signals can be used to probe the galaxy–halo mass relations and their environmental dependences in the halo occupation or conditional luminosity function framework.

  3. Galaxy–Galaxy Weak-lensing Measurements from SDSS. I. Image Processing and Lensing Signals

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Wentao [Key Laboratory for Research in Galaxies and Cosmology, Shanghai Astronomical Observatory, Nandan Road 80, Shanghai 200030 (China); Yang, Xiaohu; Zhang, Jun; Tweed, Dylan [Department of Physics, Carnegie Mellon University, Pittsburgh, PA 15213 (United States); Fu, Liping; Shu, Chenggang [Shanghai Key Lab for Astrophysics, Shanghai Normal University, 100 Guilin Road, 200234, Shanghai (China); Mo, H. J. [Department of Astronomy, University of Massachusetts, Amherst, MA 01003-9305 (United States); Bosch, Frank C. van den [Department of Astronomy, Yale University, P.O. Box 208101, New Haven, CT 06520-8101 (United States); Li, Ran [Key Laboratory for Computational Astrophysics, Partner Group of the Max Planck Institute for Astrophysics, National Astronomical Observatories, Chinese Academy of Sciences, Beijing, 100012 (China); Li, Nan [Department of Astronomy and Astrophysics, The University of Chicago, 5640 South Ellis Avenue, Chicago, IL 60637 (United States); Liu, Xiangkun; Pan, Chuzhong [Department of Astronomy, Peking University, Beijing 100871 (China); Wang, Yiran [Department of Astronomy, University of Illinois at Urbana-Champaign, 1002 W. Green Street, Urbana, IL 61801 (United States); Radovich, Mario, E-mail: walt@shao.ac.cn, E-mail: xyang@sjtu.edu.cn [INAF-Osservatorio Astronomico di Napoli, via Moiariello 16, I-80131 Napoli (Italy)

    2017-02-10

    We present our image processing pipeline that corrects the systematics introduced by the point-spread function (PSF). Using this pipeline, we processed Sloan Digital Sky Survey (SDSS) DR7 imaging data in r band and generated a galaxy catalog containing the shape information. Based on our shape measurements of the galaxy images from SDSS DR7, we extract the galaxy–galaxy (GG) lensing signals around foreground spectroscopic galaxies binned in different luminosities and stellar masses. We estimated the systematics, e.g., selection bias, PSF reconstruction bias, PSF dilution bias, shear responsivity bias, and noise rectification bias, which in total is between −9.1% and 20.8% at 2 σ levels. The overall GG lensing signals we measured are in good agreement with Mandelbaum et al. The reduced χ {sup 2} between the two measurements in different luminosity bins are from 0.43 to 0.83. Larger reduced χ {sup 2} from 0.60 to 1.87 are seen for different stellar mass bins, which is mainly caused by the different stellar mass estimator. The results in this paper with higher signal-to-noise ratio are due to the larger survey area than SDSS DR4, confirming that more luminous/massive galaxies bear stronger GG lensing signals. We divide the foreground galaxies into red/blue and star-forming/quenched subsamples and measure their GG lensing signals. We find that, at a specific stellar mass/luminosity, the red/quenched galaxies have stronger GG lensing signals than their counterparts, especially at large radii. These GG lensing signals can be used to probe the galaxy–halo mass relations and their environmental dependences in the halo occupation or conditional luminosity function framework.

  4. Gravitationally lensed quasars in Gaia: I. Resolving small-separation lenses

    Science.gov (United States)

    Lemon, Cameron A.; Auger, Matthew W.; McMahon, Richard G.; Koposov, Sergey E.

    2017-12-01

    Gaia's exceptional resolution (FWHM ∼ 0.1 arcsec) allows identification and cataloguing of the multiple images of gravitationally lensed quasars. We investigate a sample of 49 known lensed quasars in the Sloan Digital Sky Survey (SDSS) footprint, with image separations less than 2 arcsec, and find that eight are detected with multiple components in the first Gaia data release. In the case of the 41 single Gaia detections, we generally are able to distinguish these lensed quasars from single quasars when comparing Gaia flux and position measurements to those of Pan-STARRS and SDSS. This is because the multiple images of these lensed quasars are typically blended in ground-based imaging and therefore the total flux and a flux-weighted centroid are measured, which can differ significantly from the fluxes and centroids of the individual components detected by Gaia. We compare the fluxes through an empirical fit of Pan-STARRS griz photometry to the wide optical Gaia bandpass values using a sample of isolated quasars. The positional offsets are calculated from a recalibrated astrometric SDSS catalogue. Applying flux and centroid difference criteria to spectroscopically confirmed quasars, we discover four new sub-arcsecond-separation lensed quasar candidates which have two distinct components of similar colour in archival Canada-France-Hawaii Telescope or Hyper Suprime Cam data. Our method based on single Gaia detections can be used to identify the ∼1400 lensed quasars with image separation above 0.5 arcsec, expected to have only one image bright enough to be detected by Gaia.

  5. GALAXY SCALE LENSES IN THE RCS2. I. FIRST CATALOG OF CANDIDATE STRONG LENSES

    International Nuclear Information System (INIS)

    Anguita, T.; Barrientos, L. F.; Gladders, M. D.; Faure, C.; Yee, H. K. C.; Gilbank, D. G.

    2012-01-01

    We present the first galaxy scale lens catalog from the second Red-Sequence Cluster Survey. The catalog contains 60 lensing system candidates comprised of Luminous Red Galaxy (LRG) lenses at 0.2 ∼ 11 [M ☉ h –1 ]) and rich in dark matter (M/L-bar∼ 14 [M ☉ /L ☉,B h]). Even though a slight increasing trend in the mass-to-light ratio is observed from z = 0.2 to z = 0.5, current redshift and light profile measurements do not allow stringent constraints on the mass-to-light ratio evolution of LRGs.

  6. [Current care and maintenance systems for contact lenses].

    Science.gov (United States)

    Lipener, César; Ray, Camila Baracat Mendina

    2008-01-01

    The proper maintenance of contact lenses is crucial for their success and to maintain the continuity of their use. Many patients abandon the use of their lenses due to problems that could be solved with relatively simple treatments. The misuse of lenses, coupled with poor adjustment, contamination, eye disease and environmental factors may increase the number of corneal infections through the proliferation of microorganisms. This article aims to provide contact lens care and maintenance updates.

  7. Plasma lenses for SLAC Final Focus Test facility

    International Nuclear Information System (INIS)

    Betz, D.; Cline, D.; Joshi, C.; Rajagopalan, S.; Rosenzweig, J.; Su, J.J.; Williams, R.; Chen, P.; Gundersen, M.; Katsouleas, T.; Norem, J.

    1991-01-01

    A collaborative group of accelerator and plasma physicists and engineers has formed with an interest in exploring the use of plasma lenses to meet the needs of future colliders. Analytic and computational models of plasma lenses are briefly reviewed and several design examples for the SLAC Final Focus Test Beam are presented. The examples include discrete, thick, and adiabatic lenses. A potential plasma source with desirable lens characteristics is presented

  8. Prospects for weak lensing studies with new radio telescopes

    OpenAIRE

    M. L. Brown

    2012-01-01

    I outline the prospects for performing weak lensing studies with the new generation of radio telescopes that are coming online now and in the future. I include a description of a proposed technique to use polarization observations in radio weak lensing analyses which could prove extremely useful for removing a contaminating signal from intrinsic alignments. Ultimately, the Square Kilometre Array promises to be an exceptional instrument for performing weak lensing studies due to the high resol...

  9. Phosphorylcholine and phosphorylethanolamine in human and rhesus monkey lenses.

    Science.gov (United States)

    Jernigan, H M; Zigler, J S

    1989-11-01

    Phosphorylcholine (P-choline) and phosphorylethanolamine (P-ethanolamine) are important precursors of phospholipids. The metabolism and concentration of P-choline has been shown to change in animal models of cataract, especially in oxidatively or osmotically stressed rat lenses. The concentrations of P-choline and P-ethanolamine were determined in monkey lenses and in normal and cataractous human lenses, and the rate of synthesis of P-choline was determined in human and monkey lenses. The concentration of P-choline in 53 clear human lenses was 0.94 mM (+/- 0.31 S.D.) and was relatively unaffected by age, eye bank storage, or freezing. There was a 70% decrease in P-choline in brown cataracts but no significant change from normal in non-brown cataracts. The concentration of P-ethanolamine in human lenses was 0.45 mM (+/- 0.26 S.D.), and it appeared to decrease during frozen storage of lenses and in cataracts. The concentrations of P-choline and P-ethanolamine in 12 rhesus monkey lenses were 1.51 mM (+/- 0.27 S.D.) and 0.75 mM (+/- 0.14 S.D.), respectively. The rate of synthesis of P-choline in monkey lenses incubated with [3H]choline was 8 nmol hr-1 g-1 wet weight in 1 mM choline. Adult human lenses incubated in 1 mM choline synthesized P-choline at a rate of 23 nmol hr-1 g-1 (+/- 6 S.D.). This limited capacity for P-choline synthesis in primate lenses may contribute to the lower P-choline concentration relative to rat lenses, which contain 11 mM P-choline and can synthesize P-choline at an apparent maximum rate of 130 nmol hr-1 g-1.

  10. Eye patches: Protein assembly of index-gradient squid lenses

    Energy Technology Data Exchange (ETDEWEB)

    Cai, J.; Townsend, J. P.; Dodson, T. C.; Heiney, P. A.; Sweeney, A. M.

    2017-08-10

    A parabolic relationship between lens radius and refractive index allows spherical lenses to avoid spherical aberration. We show that in squid, patchy colloidal physics resulted from an evolutionary radiation of globular S-crystallin proteins. Small-angle x-ray scattering experiments on lens tissue show colloidal gels of S-crystallins at all radial positions. Sparse lens materials form via low-valence linkages between disordered loops protruding from the protein surface. The loops are polydisperse and bind via a set of hydrogen bonds between disordered side chains. Peripheral lens regions with low particle valence form stable, volume-spanning gels at low density, whereas central regions with higher average valence gel at higher densities. The proteins demonstrate an evolved set of linkers for self-assembly of nanoparticles into volumetric materials.

  11. Broadband unidirectional cloaks based on flat metasurface focusing lenses

    Science.gov (United States)

    Li, Yongfeng; Zhang, Jieqiu; Qu, Shaobo; Wang, Jiafu; Pang, Yongqiang; Xu, Zhuo; Zhang, Anxue

    2015-08-01

    Bandwidth extension and thickness reduction are now the two key issues of cloaks. In this paper, we propose to achieve broadband, thin uni-directional electromagnetic (EM) cloaks using metasurfaces. To this end, a wideband flat focusing lens is firstly devised based on high-efficiency transmissive metasurfaces. Due to the nearly dispersionless parabolic phase profile along the metasurface in the operating band, incident plane waves can be focused efficiently after passing through the metasurface. Broadband unidirectional EM cloaks were then designed by combining two identical flat lenses. Upon illumination, the incident plane waves are firstly focused by one lens and then are restored by the other lens, avoiding the cloaked region. Both simulation and experiment results verify the broadband unidirectional cloak. The broad bandwidth and small thickness of such cloaks have potential applications in achieving invisibility for electrically large objects.

  12. Weak lensing of the Lyman-alpha forest

    Science.gov (United States)

    Croft, Rupert A. C.; Romeo, Alessandro; Metcalf, R. Benton

    2018-03-01

    The angular positions of quasars are deflected by the gravitational lensing effect of foreground matter. The Lyα forest seen in the spectra of these quasars is therefore also lensed. We propose that the signature of weak gravitional lensing of the Lyα forest could be measured using similar techniques that have been applied to the lensed Cosmic Microwave Background, and which have also been proposed for application to spectral data from 21cm radio telescopes. As with 21cm data, the forest has the advantage of spectral information, potentially yielding many lensed "slices" at different redshifts. We perform an illustrative idealized test, generating a high resolution angular grid of quasars (of order arcminute separation), and lensing the Lyα forest spectra at redshifts z = 2 - 3 using a foreground density field. We find that standard quadratic estimators can be used to reconstruct images of the foreground mass distribution at z ˜ 1. There currently exists a wealth of Lyα forest data from quasar and galaxy spectral surveys, with smaller sightline separations expected in the future. Lyα forest lensing is sensitive to the foreground mass distribution at redshifts intermediate between CMB lensing and galaxy shear, and avoids the difficulties of shape measurement associated with the latter. With further refinement and application of mass reconstruction techniques, weak gravitational lensing of the high redshift Lyα forest may become a useful new cosmological probe.

  13. Using Strong Gravitational Lensing to Identify Fossil Group Progenitors

    Science.gov (United States)

    Johnson, Lucas E.; Irwin, Jimmy A.; White, Raymond E., III; Wong, Ka-Wah; Maksym, W. Peter; Dupke, Renato A.; Miller, Eric D.; Carrasco, Eleazar R.

    2018-04-01

    Fossil galaxy systems are classically thought to be the end result of galaxy group/cluster evolution, as galaxies experiencing dynamical friction sink to the center of the group potential and merge into a single, giant elliptical that dominates the rest of the members in both mass and luminosity. Most fossil systems discovered lie within z fossil criteria within the look forward time. Since strong gravitational lensing preferentially selects groups merging along the line of sight, or systems with a high mass concentration like fossil systems, we searched the CASSOWARY survey of strong-lensing events with the goal of determining whether lensing systems have any predisposition to being fossil systems or progenitors. We find that ∼13% of lensing groups are identified as traditional fossils while only ∼3% of nonlensing control groups are. We also find that ∼23% of lensing systems are traditional fossil progenitors compared to ∼17% for the control sample. Our findings show that strong-lensing systems are more likely to be fossil/pre-fossil systems than comparable nonlensing systems. Cumulative galaxy luminosity functions of the lensing and nonlensing groups also indicate a possible, fundamental difference between strong-lensing and nonlensing systems’ galaxy populations, with lensing systems housing a greater number of bright galaxies even in the outskirts of groups.

  14. Contact lenses fitting after intracorneal ring segments implantation in keratoconus

    Directory of Open Access Journals (Sweden)

    Luciane Bugmann Moreira

    2013-08-01

    Full Text Available PURPOSE: Evaluate contact lenses fitting after intracorneal ring implantation for keratoconus, its visual acuity and comfort. METHODS: Retrospective study of patients undergoing contact lenses fitting, after intracorneal ring for keratoconus. The criterion for contact lens fitting was unsatisfactory visual acuity with spectacle correction as referred by the patients. All patients were intolerants to contact lenses prior to intracorneal implantation. Visual acuity analysis was done by conversion of Snellen to logMAR scales. The comfort was evaluated according subjective questioning of good, medium or poor comfort. RESULTS: Nineteen patients were included in the study. Two patients (10.5% did not achieved good comfort with contact lenses and underwent penetrating keratoplasties. All the others 17 patients showed good or medium comfort. Four rigid gas-permeable contact lenses were fitted, one piggyback approach, 3 toric soft contact lenses, 2 soft lenses specially design for keratoconus and 7 disposable soft lenses. The average visual acuity improved from 0.77 ± 0.37 to 0.19 ± 0.13 logMAR units after contact lenses fitting. CONCLUSION: Contact lens fitting after intracorneal ring is possible, provides good comfort, improves visual acuity, and therefore, may postpone the need for penetrating keratoplasty.

  15. Quantitative evaluation of performance of three-dimensional printed lenses

    Science.gov (United States)

    Gawedzinski, John; Pawlowski, Michal E.; Tkaczyk, Tomasz S.

    2017-08-01

    We present an analysis of the shape, surface quality, and imaging capabilities of custom three-dimensional (3-D) printed lenses. 3-D printing technology enables lens prototypes to be fabricated without restrictions on surface geometry. Thus, spherical, aspherical, and rotationally nonsymmetric lenses can be manufactured in an integrated production process. This technique serves as a noteworthy alternative to multistage, labor-intensive, abrasive processes, such as grinding, polishing, and diamond turning. Here, we evaluate the quality of lenses fabricated by Luxexcel using patented Printoptical©; technology that is based on an inkjet printing technique by comparing them to lenses made with traditional glass processing technologies (grinding, polishing, etc.). The surface geometry and roughness of the lenses were evaluated using white-light and Fizeau interferometers. We have compared peak-to-valley wavefront deviation, root mean square (RMS) wavefront error, radii of curvature, and the arithmetic roughness average (Ra) profile of plastic and glass lenses. In addition, the imaging performance of selected pairs of lenses was tested using 1951 USAF resolution target. The results indicate performance of 3-D printed optics that could be manufactured with surface roughness comparable to that of injection molded lenses (Ra<20 nm). The RMS wavefront error of 3-D printed prototypes was at a minimum 18.8 times larger than equivalent glass prototypes for a lens with a 12.7 mm clear aperture, but, when measured within 63% of its clear aperture, the 3-D printed components' RMS wavefront error was comparable to glass lenses.

  16. Reconstructing the lensing mass in the Universe from photometric catalogue data

    NARCIS (Netherlands)

    Collett, Thomas E.; Marshall, Philip J.; Auger, Matthew W.; Hilbert, Stefan; Suyu, Sherry H.; Greene, Zachary; Treu, Tommaso; Fassnacht, Christopher D.; Koopmans, Leon V. E.; Bradac, Marusa; Blandford, Roger D.

    2013-01-01

    High precision cosmological distance measurements towards individual objects such as time delay gravitational lenses or Type Ia supernovae are affected by weak lensing perturbations by galaxies and groups along the line of sight. In time delay gravitational lenses, 'external convergence',

  17. Lenses generated by intermittent currents

    Science.gov (United States)

    Nof, Doron

    1991-03-01

    momentum constraint, which is rarely used in oceanographic modelling, has been applied. The details of the second process (i.e. chain-wall interaction) are examined with the aid of the (above) results for the chained offshore eddies and the single eddy-wall interaction analysis of NOF (1988, Journal of Marine Research, 46, 527dash555). A combination of these two studies shows that a chain of lens-like eddies forced against a wall would leak fluid until all the eddies in the chain are merely 'kissing' the wall. Simple qualitative laboratory experiments on a rotating table support the conclusion that intermittencies in the current's transport lead to a group of eddies that leak along the wall. Such a group is formed even if the equivalent steady current is stable to long wave perturbation, i.e. the laboratory current would not have broken up had it not been terminating shoprlty after its formation. It is suggested that the observed mid-Atlantic eddies resulting fromt he Mediterranean outflow (Meddies) might be formed by a mechanism similar to our newly suggested process.

  18. Tevatron Electron Lenses: Design and Operation

    Energy Technology Data Exchange (ETDEWEB)

    Shiltsev, Vladimir; /Fermilab; Bishofberger, Kip; /Los Alamos; Kamerdzhiev, Vsevolod; /Fermilab; Kozub, Sergei; /Serpukhov, IHEP; Kufer, Matthew; Kuznetsov, Gennady; Martinez, Alexander; Olson, Marvin; Pfeffer, Howard; Saewert, Greg; Scarpine, Vic; /Fermilab; Seryi, Andrei; /SLAC; Solyak, Nikolai; /Fermilab; Sytnik, Veniamin; /Serpukhov, IHEP; Tiunov, Mikhail; /Novosibirsk, IYF; Tkachenko, Leonid; /Serpukhov, IHEP; Wildman, David; Wolff, Daniel; Zhang, Xiao-Long; /Fermilab

    2011-09-12

    Fermilab's Tevatron is currently the world's highest energy accelerator in which tightly focused beams of 980 GeV protons and antiprotons collide at two dedicated interaction points (IPs). Both beams share the same beam pipe and magnet aperture and, in order to avoid multiple detrimental head-on collisions, the beams are placed on separated orbits everywhere except the main IPs by using high-voltage (HV) electrostatic separators. The electromagnetic beam-beam interaction at the main IPs together with the long-range interactions between separated beams adversely affect the collider performance, reducing the luminosity integral per store (period of continuous collisions) by 10-30%. Tuning the collider operation for optimal performance becomes more and more cumbersome as the beam intensities and luminosity increase. The long-range effects which (besides being nonlinear) vary from bunch to bunch are particularly hard to mitigate. A comprehensive review of the beam-beam effects in the Tevatron Collider Run II can be found in Ref. [1]. The beam-beam effects have been the dominating sources of beam loss and lifetime limitations in the Tevatron proton-antiproton collider [1]. Electron lenses were originally proposed for compensation of electromagnetic long-range and head-on beam-beam interactions of proton and antiproton beams [2]. Results of successful employment of two electron lenses built and installed in the Tevatron are reported in [3,4,5]. In this paper we present design features of the Tevatron electron lenses (TELs), discuss the generation of electron beams, describe different modes of operation and outline the technical parameters of various subsystems.

  19. Contact Lenses for Keratoconus- Current Practice

    Science.gov (United States)

    Moschos, Marilita M.; Nitoda, Eirini; Georgoudis, Panagiotis; Balidis, Miltos; Karageorgiadis, Eleftherios; Kozeis, Nikos

    2017-01-01

    Background: Keratoconus is a chronic, bilateral, usuallly asymmetrical, non-inflammatory, ectatic disorder, being characterized by progressive steepening, thinning and apical scarring of the cornea. Initially, the patient is asymptomatic, but the visual acuity gradually decreases, resulting in significant vision loss due to the development of irregular astigmatism, myopia, corneal thinning and scarring. The classic treatment of visual rehabilitation in keratoconus is based on spectacles and contact lenses (CLs). Objective: To summarize the types of CLs used in the treatment of keratoconus. This is literature review of several important published articles focusing on the visual rehabilitation in keratoconus with CLs. Method: Gas permeable (GP) CLs have been found to achieve better best corrected visual acuity than spectacles, eliminating 3rd-order coma root-mean-square (RMS) error, 3rd-order RMS, and higher-order RMS. However, they have implicated in reduction of corneal basal epithelial cell and anterior stromal keratocyte densities. Soft CLs seem to provide greater comfort and lower cost, but the low oxygen permeability (if the lens is not a silicone hydrogel), and the inability to mask moderate to severe irregular astigmatism are the main disadvantages of them. On the other hand, scleral CLs ensure stable platforms, which eliminate high-order aberrations and provide good centration and visual acuity. Their main disadvantages include the difficulties in application and removal of these lenses along with corneal flattening and swelling. Result: The modern hybrid CLs are indicated in cases of poor centration, poor stability or intolerance with GP lenses. Finally, piggyback CL systems effectively ameliorate visual acuity, but they have been related to corneal neovascularization and giant papillary conjunctivitis. Conclusion: CLs seem to rehabilitate visual performance, diminishing the power of the cylinder and the high-order aberrations. The final choice of CLs is

  20. Precision cluster mass determination from weak lensing

    Science.gov (United States)

    Mandelbaum, Rachel; Seljak, Uroš; Baldauf, Tobias; Smith, Robert E.

    2010-07-01

    Weak gravitational lensing has been used extensively in the past decade to constrain the masses of galaxy clusters, and is the most promising observational technique for providing the mass calibration necessary for precision cosmology with clusters. There are several challenges in estimating cluster masses, particularly (a) the sensitivity to astrophysical effects and observational systematics that modify the signal relative to the theoretical expectations, and (b) biases that can arise due to assumptions in the mass estimation method, such as the assumed radial profile of the cluster. All of these challenges are more problematic in the inner regions of the cluster, suggesting that their influence would ideally be suppressed for the purpose of mass estimation. However, at any given radius the differential surface density measured by lensing is sensitive to all mass within that radius, and the corrupted signal from the inner parts is spread out to all scales. We develop a new statistic Υ(RR0) that is ideal for estimation of cluster masses because it completely eliminates mass contributions below a chosen scale (which we suggest should be about 20 per cent of the virial radius), and thus reduces sensitivity to systematic and astrophysical effects. We use simulated and analytical profiles including shape noise to quantify systematic biases on the estimated masses for several standard methods of mass estimation, finding that these can lead to significant mass biases that range from 10 to over 50 per cent. The mass uncertainties when using the new statistic Υ(RR0) are reduced by up to a factor of 10 relative to the standard methods, while only moderately increasing the statistical errors. This new method of mass estimation will enable a higher level of precision in future science work with weak lensing mass estimates for galaxy clusters.

  1. Magnified Weak Lensing Cross Correlation Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ulmer, Melville P., Clowe, Douglas I.

    2010-11-30

    This project carried out a weak lensing tomography (WLT) measurement around rich clusters of galaxies. This project used ground based photometric redshift data combined with HST archived cluster images that provide the WLT and cluster mass modeling. The technique has already produced interesting results (Guennou et al, 2010,Astronomy & Astrophysics Vol 523, page 21, and Clowe et al, 2011 to be submitted). Guennou et al have validated that the necessary accuracy can be achieved with photometric redshifts for our purposes. Clowe et al titled "The DAFT/FADA survey. II. Tomographic weak lensing signal from 10 high redshift clusters," have shown that for the **first time** via this purely geometrical technique, which does not assume a standard rod or candle, that a cosmological constant is **required** for flat cosmologies. The intent of this project is not to produce the best constraint on the value of the dark energy equation of state, w. Rather, this project is to carry out a sustained effort of weak lensing tomography that will naturally feed into the near term Dark Energy Survey (DES) and to provide invaluable mass calibration for that project. These results will greatly advance a key cosmological method which will be applied to the top-rated ground-based project in the Astro2020 decadal survey, LSST. Weak lensing tomography is one of the key science drivers behind LSST. CO-I Clowe is on the weak lensing LSST committee, and senior scientist on this project, at FNAL James Annis, plays a leading role in the DES. This project has built on successful proposals to obtain ground-based imaging for the cluster sample. By 1 Jan, it is anticipated the project will have accumulated complete 5-color photometry on 30 (or about 1/3) of the targeted cluster sample (public webpage for the survey is available at http://cencos.oamp.fr/DAFT/ and has a current summary of the observational status of various clusters). In all, the project has now been awarded the equivalent of over 60

  2. The lensing properties of the Einasto profile

    OpenAIRE

    Retana-Montenegro, E.; Frutos-Alfaro, F.

    2011-01-01

    In recent high resolution N-body CDM simulations, it has been had found that nonsingular three-parameter models, e.g. the Einasto profile has a better performance better than the singular two-parameter models, e.g. the Navarro, Frenk and White in the fitting of a wide range of dark matter halos. A problem with this profile is that the surface mass density is non-analytical for general values of the Einasto index. Therefore, its other lensing properties have the same problem. We obtain an exac...

  3. Realizable planar gradient-index solar lenses.

    Science.gov (United States)

    Kotsidas, Panagiotis; Modi, Vijay; Gordon, Jeffrey M

    2012-04-01

    The design of single element planar hemispherical gradient-index solar lenses that can accommodate the constraints of realistic materials and fabrication techniques are presented, and simulated with an extended and polychromatic solar source for concentrator photovoltaics at flux concentration values exceeding 1000 suns. The planar hemispherical far-field lens is created from a near-field unit magnification spherical gradient-index design, and illustrated with an f/1.40 square solar lens that allows lossless packing within a concentrator module.

  4. Vibrational microspectroscopy analysis of human lenses

    Science.gov (United States)

    Paluszkiewicz, C.; Piergies, N.; Sozańska, A.; Chaniecki, P.; Rękas, M.; Miszczyk, J.; Gajda, M.; Kwiatek, W. M.

    2018-01-01

    In this study we present vibrational analysis of healthy (non-affected by cataract) and cataractous human lenses by means of Raman and FTIR spectroscopy methods. The performed analysis provides complex information about the secondary structure of the proteins and conformational changes of the amino acid residues due to the formation of opacification of human lens. Briefly, the changes in the conformation of the Tyr and Trp residues and the protein secondary structure between the healthy and cataractous samples, were recognized. Moreover, the observed spectral pattern suggests that the process of cataract development does not occur uniformly over the entire volume of the lens.

  5. Electron Beam Generation in Tevatron Electron Lenses

    International Nuclear Information System (INIS)

    Kamerdzhiev, V.; Kuznetsov, G.; Shiltsev, V.; Solyak, N.; Tiunov, M.

    2006-01-01

    New type of high perveance electron guns with convex cathode has been developed. Three guns described in this article are built to provide transverse electron current density distributions needed for Electron Lenses for beam-beam compensation in the Tevatron collider. The current distribution can be controlled either by the gun geometry or by voltage on a special control electrode located near cathode. We present the designs of the guns and report results of beam measurements on the test bench. Because of their high current density and low transverse temperature of electrons, electron guns of this type can be used in electron cooling and beam-beam compensation devices

  6. Electron beam generation in Tevatron electron lenses

    International Nuclear Information System (INIS)

    Kamerdzhiev, V.; Kuznetsov, G.; Shiltsev, V.; Solyak, N.; Tiunov, M.

    2006-01-01

    New type of high perveance electron guns with convex cathode has been developed. Three guns described in this article are built to provide transverse electron current density distributions needed for Electron Lenses for beam-beam compensation in the Tevatron collider. The current distribution can be controlled either by the gun geometry or by voltage on a special control electrode located near cathode. We present the designs of the guns and report results of beam measurements on the test bench. Because of their high current density and low transverse temperature of electrons, electron guns of this type can be used in electron cooling and beam-beam compensation devices

  7. X-ray lenses with large aperture; Roentgenlinsen mit grosser Apertur

    Energy Technology Data Exchange (ETDEWEB)

    Simon, Markus

    2010-07-01

    Up to now, most X-ray imaging setups are based on absorption contrast imaging. There is a demand for focused X-rays in many X-ray analysis applications, either to increase the resolution of an imaging system, or, to reduce the time effort of an experiment through higher photon flux. For photon energies higher than 15 keV refractive X-ray optics are more efficient in comparison to non-refractive X-ray optics. The aim of this work was to develop X-ray lenses with large apertures and high transparency. By increasing the number of refracting surfaces while removing unnecessary lens material such lenses have been developed. Utilizing this approach the overall beam deflection angle is large with respect to the lens material it propagates through and so the transparency of the lens is increased. Within this work, X-ray lenses consisting of several thousands of prisms with an edge length in the range of micrometers have been developed and fabricated by deep X-ray lithography. Deep X-ray lithography enables high precision microstrucures with smooth sidewalls and large aspect ratios. The aperture of high-transparency X-ray lenses made this way is greater than 1 mm. They are suitable for photon energies in the range of 8 keV to 24 keV and offer a focal width of smaller than 10 {mu}m at a transparency of around 40%. Furthermore, rolled X-ray lenses have been developed, that are made out of a microstructured polyimide film, which is cut according to the requirements regarding focal length and photon energy. The microstructured film is fabricated by molding, using an anisotropically etched silicon wafer as molding tool. Its mean roughness is in the range of nanometers. The film features prismatic structures, its surface topology is similar to an asparagus field. The measured diameter of the point focus was 18 {mu}m to 31 {mu}m, the calculated opticla efficiency was 37%. Future work will concentrate on increasing the aspect ratio of Prism Lenses and on increasing the rolling

  8. Implications of observing and writing field notes through different lenses

    Directory of Open Access Journals (Sweden)

    Hellesø R

    2015-04-01

    Full Text Available Ragnhild Hellesø,1 Line Melby,1 Solveig Hauge21Department of Nursing Science, Institute of Health and Society, Faculty of Medicine, University of Oslo, Oslo, Norway; 2Faculty of Health and Social Studies, Telemark University College, Porsgrunn, NorwayBackground: From a philosophy of science perspective, the literature has posited that different research approaches influence field studies. Studies addressing interdisciplinary research have focused on the challenges of organizing and running interdisciplinary teams, cultural differences between and within disciplines, and constraints in conducting interdisciplinary research. Studies exploring and discussing the process and outcome of transferring observations to notes from an interdisciplinary point of view are not identified. The aim of this paper is to explore the characteristics of field notes created by researchers representing different disciplines and experiences.Methods: A case study using a modified dynamic observation method was employed. The analyses were initiated by a researcher who had not been involved in the data collection. The field notes were analyzed using three main steps.Results: The structures of both researchers' field notes were characterized by similarities in their descriptions, but the notes' foci and analytical levels differed.Conclusion: The findings contribute new insights concerning the execution of interdisciplinary observational studies. Our findings demonstrate that entering the field with different lenses produced richer and more varied data, providing a broader platform from which to discuss and interpret a study's findings. From a theoretical point of view, the findings enable a more nuanced discussion and a conceptual elaboration regarding how observational approaches should be pursued in future studies. On a practical level, the findings show that even if the researchers agree on what the overall focus in the observations should be, differences can occur in

  9. From Spheric to Aspheric Solid Polymer Lenses: A Review

    Directory of Open Access Journals (Sweden)

    Kuo-Yung Hung

    2011-01-01

    Full Text Available This paper presents a new approach in the use of MEMS technology to fabricate micro-optofluidic polymer solid lenses in order to achieve the desired profile, focal length, numerical aperture, and spot size. The resulting polymer solid lenses can be applied in optical data storage systems, imaging systems, and automated optical inspection systems. In order to meet the various needs of different applications, polymer solid lenses may have a spherical or aspherical shape. The method of fabricating polymer solid lenses is different from methods used to fabricate tunable lenses with variable focal length or needing an external control system to change the lens geometry. The current trend in polymer solid lenses is toward the fabrication of microlenses with a high numerical aperture, small clear aperture (<2 mm, and high transmittance. In this paper we focus on the use of thermal energy and electrostatic force in shaping the lens profile, including both spherical and aspherical lenses. In addition, the paper discusses how to fabricate a lens with a high numerical aperture of 0.6 using MEMS and also compares the optical characteristics of polymer lens materials, including SU-8, Norland Optical Adhesive (NOA, and cyclic olefin copolymer (COC. Finally, new concepts and applications related to micro-optofluidic lenses and polymer materials are also discussed.

  10. Shallow rainwater lenses in deltaic areas with saline seepage

    NARCIS (Netherlands)

    De Louw, Perry G.B.; Eeman, Sara; Siemon, Bernhard; Voortman, Bernard R.; Gunnink, Jan; Van Baaren, Esther S.; Oude Essink, Gualbert

    2011-01-01

    In deltaic areas with saline seepage, fresh water availability is often limited to shallow rainwater lenses lying on top of saline groundwater. Here we describe the characteristics and spatial variability of such lenses in areas with saline seepage and the mechanisms that control their occurrence

  11. Shallow rainwater lenses in deltaic areas with saline seepage

    NARCIS (Netherlands)

    Louw, de P.G.B.; Eeman, S.; Siemon, B.; `Voortman, B.R.; Gunnink, J.; Baaren, E.S.; Oude Essink, G.H.P.

    2011-01-01

    In deltaic areas with saline seepage, freshwater availability is often limited to shallow rainwater lenses lying on top of saline groundwater. Here we describe the characteristics and spatial variability of such lenses in areas with saline seepage and the mechanisms that control their occurrence and

  12. A dearth of dark matter in strong gravitational lenses

    NARCIS (Netherlands)

    Sanders, R. H.

    I show that the lensing masses of the Sloan Lens Advanced Camera Surveys sample of strong gravitational lenses are consistent with the stellar masses determined from population synthesis models using the Salpeter initial mass function. This is true in the context of both General Relativity and

  13. 30 CFR 18.66 - Tests of windows and lenses.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tests of windows and lenses. 18.66 Section 18... Tests § 18.66 Tests of windows and lenses. (a) Impact tests. A 4-pound cylindrical weight with a 1-inch-diameter hemispherical striking surface shall be dropped (free fall) to strike the window or lens in its...

  14. Gauge-invariant formalism of cosmological weak lensing

    Science.gov (United States)

    Yoo, Jaiyul; Grimm, Nastassia; Mitsou, Ermis; Amara, Adam; Refregier, Alexandre

    2018-04-01

    We present the gauge-invariant formalism of cosmological weak lensing, accounting for all the relativistic effects due to the scalar, vector, and tensor perturbations at the linear order. While the light propagation is fully described by the geodesic equation, the relation of the photon wavevector to the physical quantities requires the specification of the frames, where they are defined. By constructing the local tetrad bases at the observer and the source positions, we clarify the relation of the weak lensing observables such as the convergence, the shear, and the rotation to the physical size and shape defined in the source rest-frame and the observed angle and redshift measured in the observer rest-frame. Compared to the standard lensing formalism, additional relativistic effects contribute to all the lensing observables. We explicitly verify the gauge-invariance of the lensing observables and compare our results to previous work. In particular, we demonstrate that even in the presence of the vector and tensor perturbations, the physical rotation of the lensing observables vanishes at the linear order, while the tetrad basis rotates along the light propagation compared to a FRW coordinate. Though the latter is often used as a probe of primordial gravitational waves, the rotation of the tetrad basis is indeed not a physical observable. We further clarify its relation to the E-B decomposition in weak lensing. Our formalism provides a transparent and comprehensive perspective of cosmological weak lensing.

  15. Weak Weak Lensing : How Accurately Can Small Shears be Measured?

    NARCIS (Netherlands)

    Kuijken, K.

    2006-01-01

    Abstract: Now that weak lensing signals on the order of a percent are actively being searched for (cosmic shear, galaxy-galaxy lensing, large radii in clusters...) it is important to investigate how accurately weak shears can be determined. Many systematic effects are present, and need to be

  16. Biochemical analyses of lipids deposited on silicone hydrogel lenses

    Directory of Open Access Journals (Sweden)

    Shin Hatou

    2010-07-01

    Conclusions: The quantity of total lipid and cholesterol deposited on the 3 silicone hydrogel lenses tested did not differ. However, there were significant differences in the amounts of phospholipid deposited among the 3 silicone hydrogel lenses, of which clinical significance should be explored in the future study.

  17. Hybrid Contact Lenses for Visual Management of Patients after ...

    African Journals Online (AJOL)

    2018-04-04

    Apr 4, 2018 ... contact lenses for visual rehabilitation of postkeratoplasty patients. Materials and Methods: Twenty eyes of ... UCVA was 1.00 logarithm of the minimum angle of resolution (logMAR) which improved to 0.40 logMAR after ..... time as a measure of success of scleral lenses for patients with irregular astigmatism.

  18. Compound Refractive Lenses for Thermal Neutron Applications

    Energy Technology Data Exchange (ETDEWEB)

    Gary, Charles K.

    2013-11-12

    This project designed and built compound refractive lenses (CRLs) that are able to focus, collimate and image using thermal neutrons. Neutrons are difficult to manipulate compared to visible light or even x rays; however, CRLs can provide a powerful tool for focusing, collimating and imaging neutrons. Previous neutron CRLs were limited to long focal lengths, small fields of view and poor resolution due to the materials available and manufacturing techniques. By demonstrating a fabrication method that can produce accurate, small features, we have already dramatically improved the focal length of thermal neutron CRLs, and the manufacture of Fresnel lens CRLs that greatly increases the collection area, and thus efficiency, of neutron CRLs. Unlike a single lens, a compound lens is a row of N lenslets that combine to produce an N-fold increase in the refraction of neutrons. While CRLs can be made from a variety of materials, we have chosen to mold Teflon lenses. Teflon has excellent neutron refraction, yet can be molded into nearly arbitrary shapes. We designed, fabricated and tested Teflon CRLs for neutrons. We demonstrated imaging at wavelengths as short as 1.26 ? with large fields of view and achieved resolution finer than 250 μm which is better than has been previously shown. We have also determined designs for Fresnel CRLs that will greatly improve performance.

  19. The theory of stochastic cosmological lensing

    Energy Technology Data Exchange (ETDEWEB)

    Fleury, Pierre; Uzan, Jean-Philippe [Institut d' Astrophysique de Paris, UMR 7095 du CNRS, 98 bis Bd Arago, 75014 Paris (France); Larena, Julien, E-mail: fleury@iap.fr, E-mail: j.larena@ru.ac.za, E-mail: uzan@iap.fr [Department of Mathematics, Rhodes University, Grahamstown 6140 (South Africa)

    2015-11-01

    On the scale of the light beams subtended by small sources, e.g. supernovae, matter cannot be accurately described as a fluid, which questions the applicability of standard cosmic lensing to those cases. In this article, we propose a new formalism to deal with small-scale lensing as a diffusion process: the Sachs and Jacobi equations governing the propagation of narrow light beams are treated as Langevin equations. We derive the associated Fokker-Planck-Kolmogorov equations, and use them to deduce general analytical results on the mean and dispersion of the angular distance. This formalism is applied to random Einstein-Straus Swiss-cheese models, allowing us to: (1) show an explicit example of the involved calculations; (2) check the validity of the method against both ray-tracing simulations and direct numerical integration of the Langevin equation. As a byproduct, we obtain a post-Kantowski-Dyer-Roeder approximation, accounting for the effect of tidal distortions on the angular distance, in excellent agreement with numerical results. Besides, the dispersion of the angular distance is correctly reproduced in some regimes.

  20. Engineering acoustic lenses with help from evolution

    Science.gov (United States)

    Ha˚Kansson, Andreas; Sánchez-Dehesa, José; Sánchis, Lorenzo

    2004-05-01

    Optimization engineering through evolutionary algorithms have proven to be very efficient, especially in hard problems containing a large set of optimization parameters. Like evolution this family of algorithms is able to tackle enormous complex problems with fairly simple means. Here, a simple genetic algorithm [J. H. Holland, Adaptation in Natural and Artificial Systems (Univ. of Michigan, Ann Arbor, 1975)] is used in conjunction with the multiple scattering theory [L. Sánchis et al., Phys. Rev. B 67, 035422 (2003)] to fabricate a new generation of acoustic devices based on a discrete number of cylindrical scatterers. In particular, acoustic lenses [F. Cervera et al., Phys. Rev. Lett. 88, 023902 (2002)] with flat surfaces have been designed to focus the sound in a fixed focal point for one or multiple frequencies. Each scatterer is carefully placed using the optimization method within the preset boundary conditions, to maximize the pressure contribution in the chosen focal spot. With this method acoustic lenses with very low f-numbers of the order 0.3 and with amplifications over 12 dB have been estimated using a reduced number of scatterers (~60). Preliminary results obtained from the experimental realization of the designed devices confirm our predictions.

  1. Determination of injection molding process windows for optical lenses using response surface methodology.

    Science.gov (United States)

    Tsai, Kuo-Ming; Wang, He-Yi

    2014-08-20

    This study focuses on injection molding process window determination for obtaining optimal imaging optical properties, astigmatism, coma, and spherical aberration using plastic lenses. The Taguchi experimental method was first used to identify the optimized combination of parameters and significant factors affecting the imaging optical properties of the lens. Full factorial experiments were then implemented based on the significant factors to build the response surface models. The injection molding process windows for lenses with optimized optical properties were determined based on the surface models, and confirmation experiments were performed to verify their validity. The results indicated that the significant factors affecting the optical properties of lenses are mold temperature, melt temperature, and cooling time. According to experimental data for the significant factors, the oblique ovals for different optical properties on the injection molding process windows based on melt temperature and cooling time can be obtained using the curve fitting approach. The confirmation experiments revealed that the average errors for astigmatism, coma, and spherical aberration are 3.44%, 5.62%, and 5.69%, respectively. The results indicated that the process windows proposed are highly reliable.

  2. Gravitational lensing of gravitational waves from merging neutron star binaries

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yun; Stebbins, Albert; Turner, Edwin L.

    1996-05-01

    We discuss the gravitational lensing of gravitational waves from merging neutron star binaries, in the context of advanced LIGO type gravitational wave detectors. We consider properties of the expected observational data with cut on the signal-to-noise ratio \\rho, i.e., \\rho>\\rho_0. An advanced LIGO should see unlensed inspiral events with a redshift distribution with cut-off at a redshift z_{\\rm max} < 1 for h \\leq 0.8. Any inspiral events detected at z>z_{\\rm max} should be lensed. We compute the expected total number of events which are present due to gravitational lensing and their redshift distribution for an advanced LIGO in a flat Universe. If the matter fraction in compact lenses is close to 10\\%, an advanced LIGO should see a few strongly lensed events per year with \\rho >5.

  3. [Quality of life in patients wearing scleral lenses].

    Science.gov (United States)

    Picot, C; Gauthier, A-S; Campolmi, N; Delbosc, B

    2015-09-01

    To evaluate the contribution of scleral lenses in terms of improving the quality of life in the treatment of astigmatism after penetrating keratoplasty or in keratoconus. We conducted an observational retrospective study, evaluating quality of life (QOL) of patients who failed to adapt to RPG lenses, fitted with SPOT(®) scleral lenses between October 2007 and March 2011 in the University Hospital of Besançon Department of Ophthalmology. QOL was assessed before and after scleral lens adaptation with the French version of the National Eye Institute Visual Function Questionnaire 25 (NEI-VFQ 25). We included 47 patients (83 eyes) fitted with scleral lenses on one or both eyes: 56 eyes with keratoconus and 27 post-keratoplasty eyes. The average duration of wearing scleral lenses was 18±10months and the average wearing time was 14±3hours per day. The rate of participation in the survey was 86.5% (41 patients). Visual acuity in the better eye progressed from 0.68±0.46 to 0.15±0.17 logMAR at the 6th month after scleral lens adaptation (Pscleral lenses for at least 6 months were significantly higher than those without scleral lenses, with a global score of 80.2/100 with, versus 48.1/100 without, scleral lenses (P0.05). Scleral lenses showed a significant improvement in quality of life for patients who had failed or are intolerant to conventional rigid gas permeable contact lenses. In our two main optical indications, keratoconus and keratoplasty, they represent an alternative or a step prior to surgery. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  4. A simple technique of intraocular lenses explantation for single-piece foldable lenses

    Directory of Open Access Journals (Sweden)

    Arup Bhaumik

    2017-01-01

    Full Text Available Foldable intraocular lenses (IOLs are most commonly used in modern-day cataract surgery. Explantation of these IOLs is not frequently encountered, but sometimes extreme situations may demand the same. Commonly explantation is achieved by bisecting the IOL inside the anterior chamber with a cutter and delivering the pieces out one by one. This may require corneal wound extension with associated damage and endothelial loss leading to visual deterioration. We devised a simple, innovative IOL explantation technique utilizing a modified Alcon A cartridge and snare. This can successfully refold the IOL to be explanted inside the eye and deliver it out through the same wound. The device has limitations with very thick optic lenses, multipiece, and silicon IOLs. In conclusion, we describe a simple, innovative, and reproducible technique to explant almost any single piece IOL without compromising the original surgery and yielding very satisfactory outcomes.

  5. [Toric add-on intraocular lenses for correction of high astigmatism after pseudophakic keratoplasty].

    Science.gov (United States)

    Hassenstein, A; Niemeck, F; Giannakakis, K; Klemm, M

    2017-06-01

    Perforating keratoplasty shows good morphological results with a clear cornea; however, a limiting factor is often the resulting astigmatism, which cannot be corrected with either glasses or contact lenses (CL) in up to 20% of the patients. We retrospectively investigated 15 patients after pseudophakic perforating keratoplasty, who received implantation of toric add-on intraocular lenses (IOL) to correct astigmatism. The mean preoperative astigmatism of 6.5 diopter (dpt) could be reduced to a mean postoperative value of 1.0 dpt. The mean visual acuity could be improved from a preoperative value of sc one case of a lens extension tear. Based on our good experiences we now provide toric add-on IOL to all patients with pseudophakic perforating keratoplasty when this cannot be corrected or only insufficiently corrected by conservative methods.

  6. UV laser ablation of intraocular lenses: SEM and AFM microscopy examination of the biomaterial surface

    International Nuclear Information System (INIS)

    Spyratou, E.; Asproudis, I.; Tsoutsi, D.; Bacharis, C.; Moutsouris, K.; Makropoulou, M.; Serafetinides, A.A.

    2010-01-01

    Several new materials and patterns are studied for the formation and etching of intraocular lenses (IOLs), in order to improve their optical properties, to reduce the diffractive aberrations and to decrease the incidence of posterior capsular opacification. The aim of this study is to investigate the use of UV (λ = 266 nm) laser pulses to ablate the intraocular lenses materials, and thus to provide an alternative to conventional surface shaping techniques for IOLs fabrication. Ablation experiments were conducted using various polymer substrates of hydrophobic acrylic IOLs and PMMA IOLs. We investigated the ablation efficiency and the morphology of the ablated area by imaging the surface modification with atomic force microscopy (AFM) and scanning electron microscopy (SEM). The morphological appearance of IOL samples reveals the effect of a photochemical and photothermal ablation mechanism.

  7. GALAXY SCALE LENSES IN THE RCS2. I. FIRST CATALOG OF CANDIDATE STRONG LENSES

    Energy Technology Data Exchange (ETDEWEB)

    Anguita, T. [Centro de Astro-Ingenieria, Departamento de Astronomia y Astrofisica, Pontificia Universidad Catolica de Chile, Casilla 306, Santiago (Chile); Barrientos, L. F. [Departamento de Astronomia y Astrofisica, Pontificia Universidad Catolica de Chile, Casilla 306, Santiago (Chile); Gladders, M. D. [Department of Astronomy and Astrophysics, University of Chicago, 5640 S. Ellis Avenue, Chicago, IL 60637 (United States); Faure, C. [Laboratoire d' Astrophysique, Ecole Polytechnique Federale de Lausanne (EPFL), Obervatoire de Sauverny, CH-1290 Versoix (Switzerland); Yee, H. K. C.; Gilbank, D. G. [Department of Astronomy and Astrophysics, University of Toronto, 50 St George Street, Toronto, Ontario, M5S 3H4 (Canada)

    2012-04-01

    We present the first galaxy scale lens catalog from the second Red-Sequence Cluster Survey. The catalog contains 60 lensing system candidates comprised of Luminous Red Galaxy (LRG) lenses at 0.2 {approx}< z {approx}< 0.5 surrounded by blue arcs or apparent multiple images of background sources. The catalog is a valuable complement to previous galaxy-galaxy lens catalogs as it samples an intermediate lens redshift range and is composed of bright sources and lenses that allow easy follow-up for detailed analysis. Mass and mass-to-light ratio estimates reveal that the lens galaxies are massive ( M-bar {approx} 5.5 Multiplication-Sign 10{sup 11} [M{sub Sun} h{sup -1}]) and rich in dark matter (M/L-bar{approx} 14 [M{sub Sun }/L{sub Sun ,B} h]). Even though a slight increasing trend in the mass-to-light ratio is observed from z = 0.2 to z = 0.5, current redshift and light profile measurements do not allow stringent constraints on the mass-to-light ratio evolution of LRGs.

  8. Lensing and dynamics in two simple steps

    Science.gov (United States)

    Agnello, A.; Auger, M. W.; Evans, N. W.

    2013-02-01

    We present a ready-to-use method to constrain the density distribution in spherically symmetric early-type galaxy lenses. Assuming a power-law density profile, then joint use of the virial theorem and the lens equation yields simple formulae for the power-law index (or logarithmic density gradient). Any dependence on orbital anisotropy can be tightly constrained or even erased completely. Our results rely just on surface brightnesses and line-of-sight kinematics, making deprojection unnecessary. We revisit three systems that have already been examined in the literature (the Cosmic Horseshoe, the Jackpot and B1608+656) and provide our estimates. Finally, we show that the method yields a good approximation for the density profile even when the true profile is a broken power law, albeit with a mild bias towards isothermality.

  9. Weak lensing galaxy cluster field reconstruction

    Science.gov (United States)

    Jullo, E.; Pires, S.; Jauzac, M.; Kneib, J.-P.

    2014-02-01

    In this paper, we compare three methods to reconstruct galaxy cluster density fields with weak lensing data. The first method called FLens integrates an inpainting concept to invert the shear field with possible gaps, and a multi-scale entropy denoising procedure to remove the noise contained in the final reconstruction, that arises mostly from the random intrinsic shape of the galaxies. The second and third methods are based on a model of the density field made of a multi-scale grid of radial basis functions. In one case, the model parameters are computed with a linear inversion involving a singular value decomposition (SVD). In the other case, the model parameters are estimated using a Bayesian Monte Carlo Markov Chain optimization implemented in the lensing software LENSTOOL. Methods are compared on simulated data with varying galaxy density fields. We pay particular attention to the errors estimated with resampling. We find the multi-scale grid model optimized with Monte Carlo Markov Chain to provide the best results, but at high computational cost, especially when considering resampling. The SVD method is much faster but yields noisy maps, although this can be mitigated with resampling. The FLens method is a good compromise with fast computation, high signal-to-noise ratio reconstruction, but lower resolution maps. All three methods are applied to the MACS J0717+3745 galaxy cluster field, and reveal the filamentary structure discovered in Jauzac et al. We conclude that sensitive priors can help to get high signal-to-noise ratio, and unbiased reconstructions.

  10. Fitting miniscleral contact lenses in Korean patients with keratoconus.

    Science.gov (United States)

    Kim, Sujin; Lee, Jong Soo; Park, Young Kee; Lee, Seung Uk; Park, Young Min; Lee, Jong Heon; Lee, Ji-Eun

    2017-07-01

    The aim was to evaluate the clinical results of fitting MSD miniscleral contact lenses (MSD; Happy Vision Corp, Anyang, Korea) in Korean patients with keratoconus. This report presents a retrospective case review of 38 keratoconic patients fitted with MSD lenses. Visual acuity, comfort, mean wear time, final lens parameters, relationships between sagittal depth and topographic indices, success rate with the first lens ordered and adverse events were documented. The mean logMAR visual acuity was improved from 0.85 ± 0.78 with glasses and 0.28 ± 0.29 with corneal rigid gas-permeable lenses to 0.10 ± 0.11 with miniscleral contact lenses. Ninety-seven per cent of patients found the miniscleral contact lenses to be comfortable and the mean daily wear time was 10.1 ± 2.3 hours. The mean sagittal depth was 4.70 ± 0.35 mm and there was no correlation between sagittal depth and topographic indices. An average of 3.4 trial lenses was needed to decide the ordered lens and 1.3 ordered lenses to achieve the optimal fitting. One patient discontinued the wear of the lenses after three months due to discomfort. The use of MSD miniscleral contact lenses is a good alternative for patients with keratoconus and for those who failed to respond to other types of lens rehabilitation that results in both successful visual outcome and comfort. © 2016 Optometry Australia.

  11. Effects of refrigeration on daily microbial bioburden of hydrogel lenses.

    Science.gov (United States)

    Lapple, W J; Snyder, A C; Tuovinen, O H

    1987-03-01

    Microbial bioburden of contact lenses was evaluated in connection with lens care by refrigeration. Subjects wore new hydrogel contact lenses for approximately 8 hours. The microbial bioburden initially and after an overnight refrigeration of the lens was evaluated with the use of viable counts on three different media. No major changes in viable counts were observed resulting from this method of storage. Scanning electron microscopy indicated the presence of foreign material on both new and worn lenses, presumed to be debris from lens manufacture and mucoid deposits from daily wear. Microbial colonization was not apparent and single bacterial cells could not be discerned on the micrographs.

  12. [Implantation of intraocular lenses. Bullous keratopathy in pseudophakos].

    Science.gov (United States)

    Alberth, B

    1982-09-01

    The author presents his views on the implantation of intraocular lenses, in connection with two pseudophakic bullous keratopathy cases. There is no medical indication for implantation. The question is whether the most important function of the eye, object vision, may be risked in order to avoid aniseikonia or to restore binocular vision? Knowing that vision can be restored with glasses or contact lenses, is it ethical to induce more or less severe postoperative complications by means of intraocular lenses? In view of the considerable success often achieved immediately after the operation, complications which may not arise years later should also be taken into consideration.

  13. Role of mini-scleral gas-permeable lenses in the treatment of corneal disorders.

    Science.gov (United States)

    Ye, Ping; Sun, Amy; Weissman, Barry A

    2007-03-01

    Case report on the clinical implications of mini-scleral gas-permeable contact lenses in the treatment of corneal disorders. Three patients with different corneal disorders were fitted with Jupiter design mini-scleral gas-permeable contact lenses. All three patients achieved excellent vision and comfort. The contact lenses were tolerated well, and no complications were observed. Mini-scleral gas-permeable contact lenses provide a good option for patients who require gas-permeable contact lenses for optimal visual function but do not tolerate corneal contact lenses. Mini-scleral lenses are also an excellent therapeutic tool in the treatment of at least some forms of severe dry eyes.

  14. Adjustable adaptive compact fluidic phoropter with no mechanical translation of lenses

    OpenAIRE

    Marks, Randall; Mathine, David L.; Peyman, Gholam; Schwiegerling, Jim; Peyghambarian, N.

    2010-01-01

    We demonstrate a compact optical phoroptor consisting of adjustable astigmatic and defocus lenses. The lenses are fluidically controlled and allow for an arbitrary refractive error to be corrected without mechanically moving lenses. Shack–Hartmann measurements were used to characterize the optical properties of the individual lenses. The lenses were then assembled into the phoropter and controlled with three separate fluid controls. The phoroptor was verified by correcting the vision of a mod...

  15. What To Know If Your Child Wants Contact Lenses

    Science.gov (United States)

    ... and wearing decorative lenses purchased from flea markets, beauty supply stores, the Internet and other sources. These ... State & Local Officials Consumers Health Professionals Science & Research Industry Scroll back to top Popular Content Home Latest ...

  16. Fluidic astigmatic and spherical lenses for ophthalmic applications

    Science.gov (United States)

    Marks, Randall Lee

    Fluidic lenses have been developed for ophthalmic applications. The lenses use a pressure differential to deform a membrane, which separates two fluids with different indexes of refraction. The change in membrane shape creates changes in the optical wavefront. By utilizing different boundary conditions on the membrane, the progression of the membrane shape can be controlled. Specifically, a circular restraint is used to produce optical power, whereas a rectangular restraint is used to produce a combination of power and astigmatism. These lenses are analyzed for dominant properties and wavefront quality. By combining 2 rectangular restraint lenses at 45° and a circular restraint lens, both orthogonal second order Zernike astigmatisms as well as second order power can be independently controlled. This combination can also be described as independent control of ophthalmic cylinder, cylinder axis, and power, which is required to create a basic phoropter. A fluidic phoropter is demonstrated and analyzed in this manuscript.

  17. Transparent nanostructured photochromic UV-blocking soft contact lenses.

    Science.gov (United States)

    Pek, Y Shona; Wu, Hong; Chow, Edwin Py; Ying, Jackie Y

    2016-06-01

    We aim to develop transparent UV-blocking photochromic soft contact lenses via polymerization of a bicontinuous nanoemulsion. Transparent nanostructured polymers were prepared by incorporating a polymerizable surfactant and thermal initiator together with water, monomers, UV blockers and photochromic dyes. The polymers were characterized using oxygen permeometer, tensile tester, electron microscope, UV spectrophotometer, corneal cell culture and testing in rabbits. The polymers have good oxygen permeability, water content, stiffness, strength and UV-blocking ability comparable to commercial UV-blocking soft contact lenses. Their response to UV light is comparable to photochromic spectacle lenses, particularly in reverse transition from colored to colorless state. They are nontoxic and nonleaching. Our photochromic UV-blocking contact lenses provide a novel alternative to photochromic spectacles.

  18. [Unusual complications after wearing hard and soft contact lenses].

    Science.gov (United States)

    Roth, H W; Teuchert, J

    1990-01-01

    In a clinical long-term study over a period of 10 years with 3850 patients wearing hard and soft contact lenses, unusual reactions of the cornea and perilimbal conjunctiva have been observed in 3% of all cases. Mainly corneal abrasions, cracks, clouds and mosaics have been observed, which were analyzed as being rare contact lens complications. The causes were lack of proper maintenance of the contact lenses, such as mistakes in cleaning and disinfecting the lenses, mishandling or toxic and allergic reactions due to cleaning and disinfection solutions. Only exact ophthalmological monitoring of the anterior parts of the eye and laboratory tests on the worn lenses permit differentiation between primary eye diseases and contact lens-induced complications.

  19. Adaptive silicone-membrane lenses: planar vs. shaped membrane

    CSIR Research Space (South Africa)

    Schneider, F

    2009-08-01

    Full Text Available In this paper the authors compare the performance and optical quality of two types of adaptive fluidic silicone-membrane lenses. The membranes feature either a homogeneous thickness, or it is shaped resulting in an inhomogeneous cross...

  20. Halloween Safety: Costumes, Candy, and Colored Contact Lenses

    Science.gov (United States)

    ... Products For Consumers Home For Consumers Consumer Updates Halloween Safety: Costumes, Candy, and Colored Contact Lenses Share ... can cause injuries that haunt you long after Halloween. Enjoy a safe and happy Halloween by following ...

  1. Gravitational lensing by a smoothly variable surface mass density

    Science.gov (United States)

    Paczynski, Bohdan; Wambsganss, Joachim

    1989-01-01

    The statistical properties of gravitational lensing due to smooth but nonuniform distributions of matter are considered. It is found that a majority of triple images had a parity characteristic for 'shear-induced' lensing. Almost all cases of triple or multiple imaging were associated with large surface density enhancements, and lensing objects were present between the images. Thus, the observed gravitational lens candidates for which no lensing object has been detected between the images are unlikely to be a result of asymmetric distribution of mass external to the image circle. In a model with smoothly variable surface mass density, moderately and highly amplified images tended to be single rather than multiple. An opposite trend was found in models which had singularities in the surface mass distribution.

  2. Lensing of 21-cm fluctuations by primordial gravitational waves.

    Science.gov (United States)

    Book, Laura; Kamionkowski, Marc; Schmidt, Fabian

    2012-05-25

    Weak-gravitational-lensing distortions to the intensity pattern of 21-cm radiation from the dark ages can be decomposed geometrically into curl and curl-free components. Lensing by primordial gravitational waves induces a curl component, while the contribution from lensing by density fluctuations is strongly suppressed. Angular fluctuations in the 21-cm background extend to very small angular scales, and measurements at different frequencies probe different shells in redshift space. There is thus a huge trove of information with which to reconstruct the curl component of the lensing field, allowing tensor-to-scalar ratios conceivably as small as r~10(-9)-far smaller than those currently accessible-to be probed.

  3. The Danger of Using Tap Water with Contact Lenses

    Science.gov (United States)

    Acanthamoeba is a microbe that is very common in tap water. It has two forms: the trophozoite and the cyst. These trophozoites and cysts can stick to the surface of your contact lenses and then infect your eye.

  4. Clinical Study of Focus NIGHT &DAY® contact lenses | Aldebasi ...

    African Journals Online (AJOL)

    wear contact lenses for up to 3 weeks without ocular complications. Visual acuity, tear functions or corneal structure are not altered. Keywords: optometry, silicone hydrogel materials, resolution, ocular. Sudan Journal of Medical Sciences Vol.

  5. Lenses and Lessons: Using three different research perspectives in early childhood education research

    Directory of Open Access Journals (Sweden)

    S. Irvine

    2015-10-01

    Full Text Available In contemporary Western research, collaboration is held in high esteem. This developing practice is challenging particularly for researchers who follow varying theoretical approaches. However although a challenging endeavour, when viewing the one data set with different lenses, there are various lessons that can be shared. A key aspect of this paper is involved researchers' different analytical perspectives in one data set to learn more about each other's research insights, rather than become instant expert in other's approaches. The interview data reported in this paper originates from a larger study researching parents' experience of using early childhood education and care (ECEC in Australia. Here we analyse and report on two shared interview excerpts and use three different research lenses for analysis; phenomenographic study, conversational analysis and cultural-historical theory. The finding of this paper demonstrates that applying different lenses provide different interpretations, including strengths, limitations and opportunities. In this paper we argue that collaborative research practices enhance our understanding of varying research approaches and the scope, quality, translation of research and the researchers' capacity are enhanced

  6. Aqueous humor from traumatized eyes triggers cell division in the epithelia of cultured lenses

    International Nuclear Information System (INIS)

    Reddan, J.R.; Weinsieder, A.; Wilson, D.

    1979-01-01

    Experiments were designed to gain a better understanding of the relationship between ocular inflammation and cell proliferation in the lens epithelium. Aqueous humor (AH) was collected from rabbit eyes that had been subjected to a variety of traumata, including paracentesis, needle injury, X-irradiation and the intravitreal administration of an antigen. In all cases the protein content of the AH increased, reflecting a breakdown in the blood aqueous barrier. Rabbit lenses from non-traumatized eyes were isolated and cultured in medium KEI-4 containing samples of the various aqueous humors noted above. Control lenses were cultured in medium KEI-4 alone or in KEI-4 containing rabbit serum albumen at a protein concentration equivalent to that used in the AH studies. In contrast to controls, the epithelial cells of lenses exposed to AH from injured or inflamed eyes exhibited mitosis throughout the normally amitotic regions of epithelium. Moreover, the specific activity of AH collected 15 min after initial paracentesis, relative to both DNA synthesis and mitosis, exceeded that of rabbit serum. An identification of the mitogenic factor(s) in the AH may help in understanding the environmental conditions that regulate the mitotic response which normally precedes wound healing in the lens in situ, and may help in elucidating the mechanism which controls mitosis and differentiation in the lens in vivo. (author)

  7. Exploring cosmic origins with CORE: Gravitational lensing of the CMB

    Science.gov (United States)

    Challinor, A.; Allison, R.; Carron, J.; Errard, J.; Feeney, S.; Kitching, T.; Lesgourgues, J.; Lewis, A.; Zubeldía, Í.; Achucarro, A.; Ade, P.; Ashdown, M.; Ballardini, M.; Banday, A. J.; Banerji, R.; Bartlett, J.; Bartolo, N.; Basak, S.; Baumann, D.; Bersanelli, M.; Bonaldi, A.; Bonato, M.; Borrill, J.; Bouchet, F.; Boulanger, F.; Brinckmann, T.; Bucher, M.; Burigana, C.; Buzzelli, A.; Cai, Z.-Y.; Calvo, M.; Carvalho, C.-S.; Castellano, G.; Chluba, J.; Clesse, S.; Colantoni, I.; Coppolecchia, A.; Crook, M.; d'Alessandro, G.; de Bernardis, P.; de Gasperis, G.; De Zotti, G.; Delabrouille, J.; Di Valentino, E.; Diego, J.-M.; Fernandez-Cobos, R.; Ferraro, S.; Finelli, F.; Forastieri, F.; Galli, S.; Genova-Santos, R.; Gerbino, M.; González-Nuevo, J.; Grandis, S.; Greenslade, J.; Hagstotz, S.; Hanany, S.; Handley, W.; Hernandez-Monteagudo, C.; Hervías-Caimapo, C.; Hills, M.; Hivon, E.; Kiiveri, K.; Kisner, T.; Kunz, M.; Kurki-Suonio, H.; Lamagna, L.; Lasenby, A.; Lattanzi, M.; Liguori, M.; Lindholm, V.; López-Caniego, M.; Luzzi, G.; Maffei, B.; Martinez-González, E.; Martins, C. J. A. P.; Masi, S.; Matarrese, S.; McCarthy, D.; Melchiorri, A.; Melin, J.-B.; Molinari, D.; Monfardini, A.; Natoli, P.; Negrello, M.; Notari, A.; Paiella, A.; Paoletti, D.; Patanchon, G.; Piat, M.; Pisano, G.; Polastri, L.; Polenta, G.; Pollo, A.; Poulin, V.; Quartin, M.; Remazeilles, M.; Roman, M.; Rubino-Martin, J.-A.; Salvati, L.; Tartari, A.; Tomasi, M.; Tramonte, D.; Trappe, N.; Trombetti, T.; Tucker, C.; Valiviita, J.; Van de Weijgaert, R.; van Tent, B.; Vennin, V.; Vielva, P.; Vittorio, N.; Young, K.; Zannoni, M.

    2018-04-01

    Lensing of the cosmic microwave background (CMB) is now a well-developed probe of the clustering of the large-scale mass distribution over a broad range of redshifts. By exploiting the non-Gaussian imprints of lensing in the polarization of the CMB, the CORE mission will allow production of a clean map of the lensing deflections over nearly the full-sky. The number of high-S/N modes in this map will exceed current CMB lensing maps by a factor of 40, and the measurement will be sample-variance limited on all scales where linear theory is valid. Here, we summarise this mission product and discuss the science that will follow from its power spectrum and the cross-correlation with other clustering data. For example, the summed mass of neutrinos will be determined to an accuracy of 17 meV combining CORE lensing and CMB two-point information with contemporaneous measurements of the baryon acoustic oscillation feature in the clustering of galaxies, three times smaller than the minimum total mass allowed by neutrino oscillation measurements. Lensing has applications across many other science goals of CORE, including the search for B-mode polarization from primordial gravitational waves. Here, lens-induced B-modes will dominate over instrument noise, limiting constraints on the power spectrum amplitude of primordial gravitational waves. With lensing reconstructed by CORE, one can "delens" the observed polarization internally, reducing the lensing B-mode power by 60 %. This can be improved to 70 % by combining lensing and measurements of the cosmic infrared background from CORE, leading to an improvement of a factor of 2.5 in the error on the amplitude of primordial gravitational waves compared to no delensing (in the null hypothesis of no primordial B-modes). Lensing measurements from CORE will allow calibration of the halo masses of the tens of thousands of galaxy clusters that it will find, with constraints dominated by the clean polarization-based estimators. The 19

  8. What is Gravitational Lensing? (LBNL Summer Lecture Series)

    Energy Technology Data Exchange (ETDEWEB)

    Leauthaud, Alexie; Nakajima, Reiko [Berkeley Center for Cosmological Physics

    2009-07-28

    Summer Lecture Series 2009: Gravitational lensing is explained by Einstein's general theory of relativity: galaxies and clusters of galaxies, which are very massive objects, act on spacetime by causing it to become curved. Alexie Leauthaud and Reiko Nakajima, astrophysicists with the Berkeley Center for Cosmological Physics, will discuss how scientists use gravitational lensing to investigate the nature of dark energy and dark matter in the universe.

  9. Bilateral spontaneous subluxation of scleral-fixated intraocular lenses.

    Science.gov (United States)

    Assia, Ehud I; Nemet, Arie; Sachs, Dani

    2002-12-01

    Two young men with primary ectopic lenses had intracapsular cataract extraction and scleral fixation of posterior chamber intraocular lenses (PC IOLs) using 10-0 polypropylene sutures tied to the IOL eyelets. Three to 9 years after implantation, spontaneous IOL vertical subluxation occurred in all 4 eyes (5 IOL loops), probably because of suture breakage. Late subluxation of a sutured IOL may occur several years after implantation. Double fixation and thicker sutures should be considered, especially in young patients.

  10. Periodic self-lensing from accreting massive black hole binaries

    Science.gov (United States)

    D'Orazio, Daniel J.; Di Stefano, Rosanne

    2018-03-01

    Nearly 150 massive black hole binary (MBHB) candidates at sub-pc orbital separations have been reported in recent literature. Nevertheless, the definitive detection of even a single such object remains elusive. If at least one of the black holes is accreting, the light emitted from its accretion disc will be lensed by the other black hole for binary orbital inclinations near to the line of sight. This binary self-lensing could provide a unique signature of compact MBHB systems. We show that, for MBHBs with masses in the range 106-1010 M⊙ and with orbital periods less than ˜10 yr, strong lensing events should occur in one to 10s of per cent of MBHB systems that are monitored for an entire orbit. Lensing events will last from days for the less massive, shorter period MBHBs to a year for the most massive ˜10 year orbital period MBHBs. At small inclinations of the binary orbit to the line of sight, lensing must occur and will be accompanied by periodicity due to the relativistic Doppler boost. Flares at the same phase as the otherwise average flux of the Doppler modulation would be a smoking gun signature of self-lensing and can be used to constrain binary parameters. For MBHBs with separation ≳100 Schwarzschild radii, we show that finite-sized source effects could serve as a probe of MBH accretion disc structure. Finally, we stress that our lensing probability estimate implies that ˜10 of the known MBHB candidates identified through quasar periodicity should exhibit strong lensing flares.

  11. Optical and visual performance of aspheric soft contact lenses.

    Science.gov (United States)

    Efron, Suzanne; Efron, Nathan; Morgan, Philip B

    2008-03-01

    This study was conducted to investigate whether aspheric design soft contact lenses reduce ocular aberrations and result in better visual acuity and subjective appreciation of clinical performance compared with spherical soft contact lenses. A unilateral, double-masked, randomized and controlled study was undertaken in which ocular aberrations and high and low contrast logMAR visual acuity were measured on myopic subjects who wore aspheric design (Biomedics 55 Evolution, CooperVision) and spherical design (Biomedics 55, CooperVision) soft contact lenses. Ten subjects who had about -2.00 D myopia wore -2.00 D lenses and 10 subjects who had about -5.00 D myopia wore -5.00 D lenses. Measurements were made under photopic and mesopic lighting conditions. Subjects were invited to grade comfort, vision in photopic and mesopic conditions, and overall impression with the two lens types on 100 unit visual analogue scales. There was no significant difference in high contrast or low contrast visual acuity between the two lens designs of either power under photopic or mesopic conditions. Both lens designs displayed lower levels of spherical aberration compared with the "no lens" condition under photopic and mesopic light levels (p designs. There were no statistically significant differences in subjective appreciation of clinical performance between lens designs or lens powers. At least with respect to the brand of lenses tested, the fitting of aspheric design soft contact lenses does not result in superior visual acuity, aberration control, or subjective appreciation compared with equivalent spherical design soft contact lenses.

  12. Cosmological constraints from weak lensing non-Gaussian statistics

    Science.gov (United States)

    Liu, Jia; Haiman, Zoltan; Petri, Andrea; Hill, James; Hui, Lam; Kratochvil, Jan Michael; May, Morgan

    2016-01-01

    Weak gravitational lensing is one of the most promising techniques to probe dark energy. Our work to date suggests that the information in the nonlinear regime exceeds that in the two-point functions. Using the publicly available data from the 154 deg^2 CFHTLenS survey and a large suite of ray-tracing N-body simulations on a grid of 91 cosmological models, we find that constraints from peak counts are comparable to those from the power spectrum, and somewhat tighter when different smoothing scales are combined.I will also introduce the utility of cross-correlating weak galaxy lensing maps with CMB lensing maps, a technique that will be useful to probe structures at an intermediate redshift of 0.9, as larger weak lensing surveys such as HSC, DES, KiDS, Euclid, and LSST come online. We cross-correlate the CFHTLenS galaxy lensing convergence maps with Planck CMB lensing maps. Our results show two sigma tension with the constraints obtained from the Planck temperature measurements. I will discuss possible sources of the tension, including intrinsic alignments, photo-z uncertainties, masking of tSZ in the CMB maps, and the multiplicative bias.

  13. Invited Review Article: Development of crystal lenses for energetic photons

    International Nuclear Information System (INIS)

    Smither, Robert K.

    2014-01-01

    This paper follows the development of crystal diffraction lenses designed to focus energetic photons. It begins with the search for a solution to the astrophysics problem of how to detect weak astrophysics sources of gamma rays and x-rays. This led to the basic designs for a lens and to the understanding of basic limitations of lens design. The discussion of the development of crystal diffraction lenses is divided into two parts: lenses using crystals with mosaic structure, and lenses that use crystals with curved crystal planes. This second group divides into two sub-groups: (1) Curved crystals that are used to increase the acceptance angle of the diffraction of a monochromatic beam and to increase the energy bandwidth of the diffraction. (2) Curved crystals used to focus gamma ray beams. The paper describes how these two types of crystals affect the design of the corresponding crystal lenses in different fields: astrophysics, medical imaging, detection of weak, distant, gamma-ray sources, etc. The designs of crystal lenses for these applications are given in enough detail to allow the reader to design a lens for his own application

  14. Scleral contact lenses for the management of complicated ptosis.

    Science.gov (United States)

    Katsoulos, Konstantinos; Rallatos, Gerasimos Livir; Mavrikakis, Ioannis

    2017-10-20

    To present the management of three patients suffering from ptosis of various etiologies, with scleral contact lenses. Three patients (five eyes) with ptosis resulting from levator dehiscence due to long-term rigid gas permeable contact lens wear for keratoconus, phthisis bulbi, and myopathy due to Kearns-Sayre syndrome were identified during a 2-year period. They were fitted with scleral contact lenses in order to provide cosmesis by lifting the upper eyelid with the bulk of the lens, and simultaneously provide vision correction where applicable. The scleral contact lenses provided comfortable wear, significantly improved cosmesis as both palpebral aperture and marginal reflex distance were increased, and visual acuity was also subjectively and objectively improved. Two of the patients opted for the scleral contact lenses, whereas the parents of the third patient, a 10-year-old girl with Kearns-Sayre syndrome, chose to undergo ptosis surgery due to handling issues of the scleral contact lenses. Scleral contact lenses can be a useful addition to the treatment option for patients with complicated ptosis.

  15. Chromatic confocal microscope using hybrid aspheric diffractive lenses

    Science.gov (United States)

    Rayer, Mathieu; Mansfield, Daniel

    2014-05-01

    A chromatic confocal microscope is a single point non-contact distance measurement sensor. For three decades the vast majority of the chromatic confocal microscope use refractive-based lenses to code the measurement axis chromatically. However, such an approach is limiting the range of applications. In this paper the performance of refractive, diffractive and Hybrid aspheric diffractive are compared. Hybrid aspheric diffractive lenses combine the low geometric aberration of a diffractive lens with the high optical power of an aspheric lens. Hybrid aspheric diffractive lenses can reduce the number of elements in an imaging system significantly or create large hyper- chromatic lenses for sensing applications. In addition, diffractive lenses can improve the resolution and the dynamic range of a chromatic confocal microscope. However, to be suitable for commercial applications, the diffractive optical power must be significant. Therefore, manufacturing such lenses is a challenge. We show in this paper how a theoretical manufacturing model can demonstrate that the hybrid aspheric diffractive configuration with the best performances is achieved by step diffractive surface. The high optical quality of step diffractive surface is then demonstrated experimentally. Publisher's Note: This paper, originally published on 5/10/14, was replaced with a corrected/revised version on 5/19/14. If you downloaded the original PDF but are unable to access the revision, please contact SPIE Digital Library Customer Service for assistance.

  16. The epidemiology of microbial keratitis with silicone hydrogel contact lenses.

    Science.gov (United States)

    Stapleton, Fiona; Keay, Lisa; Edwards, Katie; Holden, Brien

    2013-01-01

    It was widely anticipated that after the introduction of silicone hydrogel lenses, the risk of microbial keratitis would be lower than with hydrogel lenses because of the reduction in hypoxic effects on the corneal epithelium. Large-scale epidemiological studies have confirmed that the absolute and relative risk of microbial keratitis is unchanged with overnight use of silicone hydrogel materials. The key findings include the following: (1) The risk of infection with 30 nights of silicone hydrogel use is equivalent to 6 nights of hydrogel extended wear; (2) Occasional overnight lens use is associated with a greater risk than daily lens use; (3) The rate of vision loss due to corneal infection with silicone hydrogel contact lenses is similar to that seen in hydrogel lenses; (4) The spectrum of causative organisms is similar to that seen in hydrogel lenses, and the material type does not impact the corneal location of presumed microbial keratitis; and (5) Modifiable risk factors for infection include overnight lens use, the degree of exposure, failing to wash hands before lens handling, and storage case hygiene practice. The lack of change in the absolute risk of disease would suggest that exposure to large number of pathogenic organisms can overcome any advantages obtained from eliminating the hypoxic effects of contact lenses. Epidemiological studies remain important in the assessment of new materials and modalities. Consideration of an early adopter effect with studies involving new materials and modalities and further investigation of the impact of second-generation silicone hydrogel materials is warranted.

  17. The Initial Mass Function in the Nearest Strong Lenses from SNELLS: Assessing the Consistency of Lensing, Dynamical, and Spectroscopic Constraints

    Energy Technology Data Exchange (ETDEWEB)

    Newman, Andrew B. [The Observatories of the Carnegie Institution for Science, Pasadena, CA (United States); Smith, Russell J. [Centre for Extragalactic Astronomy, University of Durham, South Road, Durham (United Kingdom); Conroy, Charlie [Department of Astronomy, Harvard University, Cambridge, MA (United States); Villaume, Alexa [Department of Astronomy and Astrophysics, University of California, Santa Cruz, CA (United States); Van Dokkum, Pieter, E-mail: anewman@obs.carnegiescience.edu [Department of Astrophysical Sciences, Yale University, New Haven, CT (United States)

    2017-08-20

    We present new observations of the three nearest early-type galaxy (ETG) strong lenses discovered in the SINFONI Nearby Elliptical Lens Locator Survey (SNELLS). Based on their lensing masses, these ETGs were inferred to have a stellar initial mass function (IMF) consistent with that of the Milky Way, not the bottom-heavy IMF that has been reported as typical for high- σ ETGs based on lensing, dynamical, and stellar population synthesis techniques. We use these unique systems to test the consistency of IMF estimates derived from different methods. We first estimate the stellar M {sub *}/ L using lensing and stellar dynamics. We then fit high-quality optical spectra of the lenses using an updated version of the stellar population synthesis models developed by Conroy and van Dokkum. When examined individually, we find good agreement among these methods for one galaxy. The other two galaxies show 2–3 σ tension with lensing estimates, depending on the dark matter contribution, when considering IMFs that extend to 0.08 M {sub ⊙}. Allowing a variable low-mass cutoff or a nonparametric form of the IMF reduces the tension among the IMF estimates to <2 σ . There is moderate evidence for a reduced number of low-mass stars in the SNELLS spectra, but no such evidence in a composite spectrum of matched- σ ETGs drawn from the SDSS. Such variation in the form of the IMF at low stellar masses ( m ≲ 0.3 M {sub ⊙}), if present, could reconcile lensing/dynamical and spectroscopic IMF estimates for the SNELLS lenses and account for their lighter M {sub *}/ L relative to the mean matched- σ ETG. We provide the spectra used in this study to facilitate future comparisons.

  18. Prosthetic soft contact lenses in Japan.

    Science.gov (United States)

    Kanemoto, Masumi; Toshida, Hiroshi; Takahiro, Itagaki; Murakami, Akira

    2007-11-01

    To investigate the use of the prosthetic iris-tinted soft contact lens, the SEED Opaque, during the past 5 years. The records of 42 outpatients (48 eyes) for whom the prosthetic soft contact lens was prescribed in the contact lens clinic of Juntendo University Hospital from July 2001 to June 2005 were investigated. An investigation was conducted in regard to the tint patterns of the prosthetic soft contact lens and the presence or absence of a transparent part in the middle, as a brown iris with a clear pupil or a solid pupil. The diagnosis, purpose of prescription, age when that lens was prescribed, complications, and changes in corrected visual acuities were analyzed retrospectively from the medical records. The mean age at the first prescription, total number of years of wearing prosthetic contact lenses, total number of prescriptions, and mean period to use each SEED Opaque lens were compared. The mean age at the first prescription of solid-pupil lens wearers was significantly younger than that for clear-pupil lens wearers (Ppossible to adjust the color and size of the cosmetic part and the pupil diameter. Further, corrected visual acuities could improve with the clear-pupil type for patients who had prescribed for improvement of visual function.

  19. Efficient lensing element for x-rays

    International Nuclear Information System (INIS)

    Ceglio, N.M.; Smith, H.I.

    1977-01-01

    An efficient x-ray lens with an effective speed of order less than approximately f/50 for lambda greater than approximately 10 A x-rays is described. Fabrication of this lensing element appears feasible using existing microfabrication technology. Diffraction and refraction are coupled in a single element to achieve efficient x-ray concentration into a single order focal spot. Diffraction is used to produce efficient ray bending (without absorption) while refraction is used only to provide appropriate phase adjustment among the various diffraction orders to insure what is essentially a single order output. The mechanism for ray bending (diffraction) is decoupled from the absorption mechanism. Refraction is used only to achieve small shifts in phase so that the associated attenuation need not be prohibitive. The x-ray lens might be described as a Blazed Fresnel Phase Plate (BFPP) with a spatially distributed phase shift within each Fresnel zone. The spatial distribution of the phase shifts is chosen to concentrate essentially all of the unabsorbed energy into a single focal spot. The BFPP transforms the incident plane wave into a converging spherical wave having an amplitude modulation which is periodic in r 2 . As a result of the periodic amplitude modulation, the BFPP will diffract energy into foci other than the first order real focus. In cases of small absorption such effects are negligible and practically all the unabsorbed energy is directed into the first order real focus

  20. Fluid Lensing and Applications to Remote Sensing of Aquatic Environments

    Science.gov (United States)

    Chirayath, Ved

    2017-01-01

    The use of fluid lensing technology on UAVs is presented as a novel means for 3D imaging of aquatic ecosystems from above the water's surface at the centimeter scale. Preliminary results are presented from airborne fluid lensing campaigns conducted over the coral reefs of Ofu Island, American Samoa (2013) and the stromatolite reefs of Shark Bay, Western Australia (2014), covering a combined area of 15km2. These reef ecosystems were revealed with centimetre-scale 2D resolution, and an accompanying 3D bathymetry model was derived using fluid lensing, Structure from Motion and UAV position data. Data products were validated from in-situ survey methods including underwater calibration targets, depth measurements and millimetre-scale high-dynamic range gigapixel photogrammetry. Fluid lensing is an experimental technology that uses water transmitting wavelengths to passively image underwater objects at high-resolution by exploiting time-varying optical lensing events caused by surface waves. Fluid lensing data are captured from low-altitude, cost-effective electric UAVs to achieve multispectral imagery and bathymetry models at the centimetre scale over regional areas. As a passive system, fluid lensing is presently limited by signal-to-noise ratio and water column inherent optical properties to approximately 10 m depth over visible wavelengths in clear waters. The datasets derived from fluid lensing present the first centimetre-scale images of a reef acquired from above the ocean surface, without wave distortion. The 3D multispectral data distinguish coral, fish and invertebrates in American Samoa, and reveal previously undocumented, morphologically distinct, stromatolite structures in Shark Bay. These findings suggest fluid lensing and multirotor electric drones represent a promising advance in the remote sensing of aquatic environments at the centimetre scale, or 'reef scale' relevant to the conservation of reef ecosystems. Pending further development and validation of

  1. Applications of electron lenses: scraping of high-power beams, beam-beam compensation, and nonlinear optics

    Energy Technology Data Exchange (ETDEWEB)

    Stancari, Giulio

    2014-09-11

    Electron lenses are pulsed, magnetically confined electron beams whose current-density profile is shaped to obtain the desired effect on the circulating beam. Electron lenses were used in the Fermilab Tevatron collider for bunch-by-bunch compensation of long-range beam-beam tune shifts, for removal of uncaptured particles in the abort gap, for preliminary experiments on head-on beam-beam compensation, and for the demonstration of halo scraping with hollow electron beams. Electron lenses for beam-beam compensation are being commissioned in the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory (BNL). Hollow electron beam collimation and halo control were studied as an option to complement the collimation system for the upgrades of the Large Hadron Collider (LHC) at CERN; a conceptual design was recently completed. Because of their electric charge and the absence of materials close to the proton beam, electron lenses may also provide an alternative to wires for long-range beam-beam compensation in LHC luminosity upgrade scenarios with small crossing angles. At Fermilab, we are planning to install an electron lens in the Integrable Optics Test Accelerator (IOTA, a 40-m ring for 150-MeV electrons) as one of the proof-of-principle implementations of nonlinear integrable optics to achieve large tune spreads and more stable beams without loss of dynamic aperture.

  2. Characterizing Lenses and Lensed Stars of High-magnification Single-lens Gravitational Microlensing Events with Lenses Passing over Source Stars

    DEFF Research Database (Denmark)

    Choi, J.-Y; Park, S.-Y; Han, C.

    2012-01-01

    -source effect. For seven events, we measure the Einstein radii and the lens-source relative proper motions. Among them, five events are found to have Einstein radii of less than 0.2 mas, making the lenses very low mass star or brown dwarf candidates. For MOA-2011-BLG-274, especially, the small Einstein radius...

  3. Flat liquid crystal diffractive lenses with variable focus and magnification

    Science.gov (United States)

    Valley, Pouria

    Non-mechanical variable lenses are important for creating compact imaging devices. Various methods employing dielectrically actuated lenses, membrane lenses, and liquid crystal lenses were previously proposed [1-4]. In This dissertation the design, fabrication, and characterization of innovative flat tunable-focus liquid crystal diffractive lenses (LCDL) are presented. LCDL employ binary Fresnel zone electrodes fabricated on Indium-Tin-Oxide using conventional micro-photolithography. The light phase can be adjusted by varying the effective refractive index of a nematic liquid crystal sandwiched between the electrodes and a reference substrate. Using a proper voltage distribution across various electrodes the focal length can be changed between several discrete values. Electrodes are shunted such that the correct phase retardation step sequence is achieved. If the number of 2pi zone boundaries is increased by a factor of m the focal length is changed from f to f/m based on the digitized Fresnel zone equation: f = rm2/2mlambda, where r m is mth zone radius, and lambda is the wavelength. The chromatic aberration of the diffractive lens is addressed and corrected by adding a variable fluidic lens. These LCDL operate at very low voltage levels (+/-2.5V ac input), exhibit fast switching times (20-150 ms), can have large apertures (>10 mm), and small form factor, and are robust and insensitive to vibrations, gravity, and capillary effects that limit membrane and dielectrically actuated lenses. Several tests were performed on the LCDL including diffraction efficiency measurement, switching dynamics, and hybrid imaging with a refractive lens. Negative focal lengths are achieved by adjusting the voltages across electrodes. Using these lenses in combination, magnification can be changed and zoom lenses can be formed. These characteristics make LCDL a good candidate for a variety of applications including auto-focus and zoom lenses in compact imaging devices such as camera

  4. Simulation of Hollow Electron Lenses as LHC Beam Halo Reducers using Merlin

    CERN Document Server

    AUTHOR|(CDS)2100784; Barlow, Roger; Appleby, Robert Barrie; Tygier, S; Bruce, Roderik; Redaelli, Stefano

    2015-01-01

    The Large Hadron Collider (LHC) and its High Luminosity (HL) upgrade foresee unprecedented stored beam energies of up to 700 MJ. The collimation system is responsible for cleaning the beam halo and is vital for successful machine operation. Hollow electron lenses (HELs) are being considered for the LHC, based on Tevatron designs and operational experience [1], for active halo control. HELs can be used as soft scraper devices, and may operate close to the beam core without undergoing damage [2]. We use the Merlin C++ accelerator libraries [3] to implement a HEL and examine the effect on the beam halo for various test scenarios.

  5. Comparison between liquid and solid tunable focus lenses

    Energy Technology Data Exchange (ETDEWEB)

    Santiago-Alvarado, A; Cruz-Martinez, V M [Universidad Tecnologica de la Mixteca, Carre. Acatlima Km 2.5 Huajuapan de Leon Oaxaca (Mexico); Vazquez-Montiel, S; Munoz-Lopez, J; Diaz-Gonzalez, G [Instituto Nacional de Astrofisica, Optica y Electronica Luis Enrique Erro 1, Tonantzintla Puebla (Mexico); Campos-Garcia, M, E-mail: santiago@mixteco.utm.mx [Centro de Ciencias Aplicadas y Desarrollo Tecnologico, Universidad Nacional Autonoma de Mexico, Apdo. Postal 70-186, 04510, D.F. Mexico (Mexico)

    2011-01-01

    Nowadays more reports in the use of tunable lenses are reported, it is due to the benefits they offer in optical systems design. A tunable lens is an optical system that can focus on a range of positions by changing dynamically one of its geometric parameters. There are several types of tunable lenses, the most known types are the liquid, the solid elastic, with variable refractive index, and lenses that use a dielectric medium. This paper presents the analysis and opto-mechanical design of two tunable lenses, a liquid lens and another Solid Elastic Lens (SEL). Both lenses are made in mounting aluminium and polydimethylsiloxane (PDMS) as refractor medium, the liquid lens use two elastic membranes containing a liquid medium between them while the SEL only use PDMS material as body of the lens (medium refractor). We describe the opto-mechanical performance of both types of lens highlighting the main features of each. Finally, results of a opto-functional comparison between these prototypes are showed.

  6. Bacterial adherence to extended wear soft contact lenses

    International Nuclear Information System (INIS)

    Aswad, M.I.; John, T.; Barza, M.; Kenyon, K.; Baum, J.

    1990-01-01

    The authors studied the adherence of Pseudomonas aeruginosa and Staphylococcus aureus to extended wear soft contact lenses (EWSCLs) with and without focal deposits using both a radiolabeling technique and electron microscopy. P. aeruginosa showed significant adherence to contact lenses in vitro. In contrast, S. aureus failed to show significant adherence to contact lenses in vitro (i.e., the radioactive uptake was not significantly above background). The extent of adherence of Pseudomonas was proportional to the number of focal deposits on the lenses. Results of electron microscopic examination showed the bacteria to be adherent primarily to large focal deposits (greater than or equal to 150 microns). There was no pseudomonal adherence to the small focal deposits (less than or equal to 50 microns) and little adherence to the areas in between the focal deposits. The authors hypothesize that worn lenses, especially those with large focal deposits, serve as a vehicle for the transport of P. aeruginosa to the cornea. This hypothesis could be a partial explanation for the high incidence of keratitis caused by P. aeruginosa in EWSCL patients

  7. Aldose reductase activity and glucose-related opacities in incubated lenses from dogs and cats.

    Science.gov (United States)

    Richter, Marianne; Guscetti, Franco; Spiess, Bernhard

    2002-11-01

    To determine responses of canine and feline lenses to incubation in a medium with a high glucose concentration. Lenses from 35 dogs and 26 cats. Glucose concentrations were measured in paired lenses from 25 dogs and 17 cats after incubation for 14 days in high-glucose (30 mmol of glucose/L) or control (6 mmol of glucose/L) medium. Aldose reductase activity was measured spectrophotometrically in the incubated lenses and in freshly frozen lenses from 10 dogs and 9 cats. Two lenses of each group were studied histologically. Canine and feline lenses in high-glucose medium developed glucose-specific opacities of variable localization and extent. Canine lenses developed equatorial vacuoles, but severity of the lesions was not associated with the age of the dog. Lenses from young cats (cats (> 4 years old) did not. Glucose concentrations were similar in all lenses incubated in high-glucose medium; however aldose reductase activity was significantly lower in lenses from older cats, compared with lenses from young cats and from dogs. High aldose reductase activity and glucose-related opacities suggest a central role for this enzyme in the pathogenesis of diabetic cataracts in dogs and cats. Because onset of diabetes mellitus usually occurs in cats > 7 years of age, low activity of aldose reductase in lenses of older cats may explain why diabetic cataracts are rare in this species despite hyperglycemia.

  8. Gravitational lensing in a cold dark matter universe

    Science.gov (United States)

    Narayan, Ramesh; White, Simon D. M.

    1988-01-01

    Gravitational lensing due to mass condensations in a biased cold dark matter (CDM) universe is investigated using the Press-Schechter (1974) theory with density fluctuation amplitudes taken from previous N-body work. Under the critical assumption that CDM haloes have small core radii, a distribution of image angular separations for high-z lensed quasars with a peak at about 1 arcsec and a half-width of a factor of about 10. Allowing for selection effects at small angular separations, this is in good agreement with the observed separations. The estimated frequency of lensing is somewhat lower than that observed, but the discrepancy can be removed by invoking amplification bias and by making a small upward adjustment to the density fluctuation amplitudes assumed in the CDM model.

  9. Observations of Cluster Substructure using Weakly Lensed Sextupole Moments

    Energy Technology Data Exchange (ETDEWEB)

    Irwin, John

    2003-08-01

    Since dark matter clusters and groups may have substructure, we have examined the sextupole content of Hubble images looking for a curvature signature in background galaxies that would arise from galaxy-galaxy lensing. We describe techniques for extracting and analyzing sextupole and higher weakly lensed moments. Indications of substructure, via spatial clumping of curved background galaxies, were observed in the image of CL0024 and then surprisingly in both Hubble deep fields. We estimate the dark cluster masses in the deep field. Alternatives to a lensing hypothesis appear improbable, but better statistics will be required to exclude them conclusively. Observation of sextupole moments would then provide a means to measure dark matter structure on smaller length scales than heretofore.

  10. Improvements to the Root Finding Algorithm in VBBinaryLensing

    Science.gov (United States)

    Heintz, Tyler; Hoag, Ava; Bozza, Valerio; Oberst, Thomas

    2018-01-01

    VBBinaryLensing is the leading code for fitting magnification maps to microlensing events by binary lenses, most especially for exoplanet discoveries. The majority of the code’s runtime is devoted to finding roots of a fifth order complex polynomial arising from the binary lens equation. This is currently accomplished via the ZROOTS subroutine, which employs Laguerre’s method. Skowron and Gould’s (2012) algorithm, which employs a combination of Laguerre’s and Newton’s methods, presents the possibility of faster runtimes. We introduce a C++ translation of Skowron and Gould’s algorithm and test it as a replacement for ZROOTS in VBBinaryLensing. We find that this new implementation both reduces the time spent finding roots and makes the code more robust in extreme regimes.

  11. Strong lensing of gravitational waves as seen by LISA.

    Science.gov (United States)

    Sereno, M; Sesana, A; Bleuler, A; Jetzer, Ph; Volonteri, M; Begelman, M C

    2010-12-17

    We discuss strong gravitational lensing of gravitational waves from the merging of massive black hole binaries in the context of the LISA mission. Detection of multiple events would provide invaluable information on competing theories of gravity, evolution and formation of structures and, possibly, constraints on H0 and other cosmological parameters. Most of the optical depth for lensing is provided by intervening massive galactic halos, for which wave optics effects are negligible. Probabilities to observe multiple events are sizable for a broad range of formation histories. For the most optimistic models, up to ≲ 4 multiple events with a signal to noise ratio ≳ 8 are expected in a 5-year mission. Chances are significant even for conservative models with either light (≲ 60%) or heavy (≲ 40%) seeds. Because of lensing amplification, some intrinsically too faint signals are brought over threshold (≲ 2 per year).

  12. Feedback as the source of imperfection in lossy perfect lenses

    Science.gov (United States)

    Rosenblatt, Gilad; Bartal, Guy; Orenstein, Meir

    2016-02-01

    The major barrier to realizing a perfect lens with left-handed materials is perceived to be their intrinsic loss. Here we show that only specific designs of perfect lenses are limited by loss—those in which material loss is translated to internal feedback. The asymptotically uniform transmission required for perfect lensing is hindered by such feedback, which generates resonances that lead to a spatial cutoff in the lens transmission. Moreover, uniform transmission and its resonant deterioration stem from completely separate classes of modal excitations. A perfect lens made of lossy left-handed materials is therefore not forbidden in principle. Pursuing perfect lens designs that avoid internal feedback offers a path towards realization of practical perfect lenses.

  13. REDDENING AND EXTINCTION TOWARD THE GALACTIC BULGE FROM OGLE-III: THE INNER MILKY WAY'S R{sub V} {approx} 2.5 EXTINCTION CURVE

    Energy Technology Data Exchange (ETDEWEB)

    Nataf, David M.; Gould, Andrew; Johnson, Jennifer A.; Skowron, Jan [Department of Astronomy, Ohio State University, 140 W. 18th Ave., Columbus, OH 43210 (United States); Fouque, Pascal [Universite de Toulouse, UPS-OMP, IRAP, Toulouse (France); Gonzalez, Oscar A. [European Southern Observatory, Karl-Schwarzschild-Strasse 2, D-85748 Garching (Germany); Udalski, Andrzej; Szymanski, Michal K.; Kubiak, Marcin; Pietrzynski, Grzegorz; Soszynski, Igor; Ulaczyk, Krzysztof; Wyrzykowski, Lukasz; Poleski, Radoslaw, E-mail: nataf@astronomy.ohio-state.edu [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland)

    2013-06-01

    We combine VI photometry from OGLE-III with VISTA Variables in The Via Lactea survey and Two Micron All Sky Survey measurements of E(J - K{sub s} ) to resolve the longstanding problem of the non-standard optical extinction toward the Galactic bulge. We show that the extinction is well fit by the relation A{sub I} = 0.7465 Multiplication-Sign E(V - I) + 1.3700 Multiplication-Sign E(J - K{sub s} ), or, equivalently, A{sub I} = 1.217 Multiplication-Sign E(V - I)(1 + 1.126 Multiplication-Sign (E(J - K{sub s} )/E(V - I) - 0.3433)). The optical and near-IR reddening law toward the inner Galaxy approximately follows an R{sub V} Almost-Equal-To 2.5 extinction curve with a dispersion {sigma}{sub R{sub V}}{approx}0.2, consistent with extragalactic investigations of the hosts of Type Ia SNe. Differential reddening is shown to be significant on scales as small as our mean field size of 6'. The intrinsic luminosity parameters of the Galactic bulge red clump (RC) are derived to be (M{sub I,RC},{sigma}{sub I,RC,0}, (V-I){sub RC,0},{sigma}{sub (V-I){sub R{sub C}}}, (J-K{sub s}){sub RC,0}) = (-0.12, 0.09, 1.06, 0.121, 0.66). Our measurements of the RC brightness, brightness dispersion, and number counts allow us to estimate several Galactic bulge structural parameters. We estimate a distance to the Galactic center of 8.20 kpc. We measure an upper bound on the tilt {alpha} Almost-Equal-To 40 Degree-Sign between the bulge's major axis and the Sun-Galactic center line of sight, though our brightness peaks are consistent with predictions of an N-body model oriented at {alpha} Almost-Equal-To 25 Degree-Sign . The number of RC stars suggests a total stellar mass for the Galactic bulge of {approx}2.3 Multiplication-Sign 10{sup 10} M{sub Sun} if one assumes a canonical Salpeter initial mass function (IMF), or {approx}1.6 Multiplication-Sign 10{sup 10} M{sub Sun} if one assumes a bottom-light Zoccali IMF.

  14. Computerized calculation scheme for toric intraocular lenses.

    Science.gov (United States)

    Langenbucher, Achim; Seitz, Berthold

    2004-06-01

    While a number of intraocular lens (IOL) power prediction formulae are well established for determination of spherical lenses, no common strategy has been published for the computation of toric IOLs. The purpose of this study is to describe a paraxial computing scheme for tracing an axial pencil of rays through the 'optical system eye' containing astigmatic refractive surfaces with their axes at random. The capabilities of this computing scheme are demonstrated with clinical examples. Based on a schematic model eye with spherocylindric surfaces, we use two alternative notations for description of vergences or prescriptions: (1) standard notation (refraction in both cardinal meridians and axis), and (2) component notation (spherical equivalent and cylindric component in 0 degrees and 45 degrees. Refractive surfaces are added to the vergence in component notation, whereas the transformation of the vergence through media is performed in the standard notation for both cardinal meridians. For calculation of the toric lens implant, a pencil of rays is traced through the spectacle and the cornea to the estimated lens position as well as backwards from the retina to the estimated lens position. For calculation of residual spectacle refraction, a pencil of rays is traced backwards from the retina through the toric lens implant and the cornea to the spectacle plane. In example 1 we calculate a 'thin toric lens' for compensation of a corneal astigmatism to achieve a spherical target refraction. In example 2 we compute a 'thick toric lens', which has to compensate for an oblique corneal astigmatism and rotate the spectacle cylinder to the against the rule position to enhance near vision. In example 3 we estimate the residual refraction at the corneal plane after implantation of a thick toric lens, when the cylinder of the lens implant is compensating the corneal cylinder in part and the axis of implantation is not fully aligned with the axis of the corneal astigmatism. This

  15. Strong Lensing Science Results from the Hyper Suprime-Cam Survey

    Science.gov (United States)

    Wong, Kenneth; HSC SSP Strong Lens Working Group

    2018-01-01

    Strong gravitational lenses are valuable objects for studying galaxy structure and cosmology. Lensing is a unique probe of the dark matter structure of galaxies, groups, and clusters, as well as an independent tool for constraining cosmological parameters. Lensing also magnifies the background source population, allowing for detailed studies of their properties at high resolution. However, strong lenses are rare and difficult to find, requiring deep wide-area high-resolution imaging surveys. With data from the ongoing Hyper Suprime-Cam (HSC) Subaru Strategic Program, we have discovered over 100 new strong lenses at the galaxy and group scale to expand the sample of lensing systems, particularly at redshifts z > 0.5, where there have previously been relatively few known lenses. We present a summary of the latest strong lensing science results from the HSC survey data taken through the S17A semester.

  16. 21 CFR 801.410 - Use of impact-resistant lenses in eyeglasses and sunglasses.

    Science.gov (United States)

    2010-04-01

    ... frequency of eye injuries resulting from the shattering of ordinary crown glass lenses indicates that the... multifocal, bioconcave, myodisc and minus lenticular, custom laminate and cemented assembly lenses shall be...

  17. Shadows and strong gravitational lensing: a brief review

    Science.gov (United States)

    Cunha, Pedro V. P.; Herdeiro, Carlos A. R.

    2018-04-01

    For ultra compact objects, light rings and fundamental photon orbits (FPOs) play a pivotal role in the theoretical analysis of strong gravitational lensing effects, and of BH shadows in particular. In this short review, specific models are considered to illustrate how FPOs can be useful in order to understand some non-trivial gravitational lensing effects. This paper aims at briefly overviewing the theoretical foundations of these effects, touching also some of the related phenomenology, both in general relativity and alternative theories of gravity, hopefully providing some intuition and new insights for the underlying physics, which might be critical when testing the Kerr black hole hypothesis.

  18. Application and System Design of Elastomer Based Optofluidic Lenses

    Science.gov (United States)

    Savidis, Nickolaos

    Adaptive optic technology has revolutionized real time correction of wavefront aberrations. Optofluidic based applied optic devices have offered an opportunity to produce flexible refractive lenses in the correction of wavefronts. Fluidic lenses have superiority relative to their solid lens counterparts in their capabilities of producing tunable optical systems, that when synchronized, can produce real time variable systems with no moving parts. We have developed optofluidic fluidic lenses for applications of applied optical devices, as well as ophthalmic optic devices. The first half of this dissertation discusses the production of fluidic lenses as optical devices. In addition, the design and testing of various fluidic systems made with these components are evaluated. We begin with the creation of spherical or defocus singlet fluidic lenses. We then produced zoom optical systems with no moving parts by synchronizing combinations of these fluidic spherical lenses. The variable power zoom system incorporates two singlet fluidic lenses that are synchronized. The coupled device has no moving parts and has produced a magnification range of 0.1 x to 10 x or a 20 x magnification range. The chapter after fluidic zoom technology focuses on producing achromatic lens designs. We offer an analysis of a hybrid diffractive and refractive achromat that offers discrete achromatized variable focal lengths. In addition, we offer a design of a fully optofluidic based achromatic lens. By synchronizing the two membrane surfaces of the fluidic achromat we develop a design for a fluidic achromatic lens. The second half of this dissertation discusses the production of optofluidic technology in ophthalmic applications. We begin with an introduction to an optofluidic phoropter system. A fluidic phoropter is designed through the combination of a defocus lens with two cylindrical fluidic lenses that are orientated 45° relative to each other. Here we discuss the designs of the fluidic

  19. Gravitational Lensing in the metric theory proposed by Sobouti

    Science.gov (United States)

    Bernal, Tula; Mendoza, Sergio

    2008-12-01

    Recently, Y. Sobouti (2007) has provided a metric theory f(R) that can account for certain dynamical anomalies observed in spiral galaxies. Mendoza & Rosas-Guevara (2007) have shown that in this theory there is an extra-bending as compared to standard general relativity. In the present work we have developed in more specific detail this additional lensing effect and we have made evaluations of the α parameter used in the model adjusting the theory to observations in X-rays of 13 clusters of galaxies with gravitational lensing ([6]).

  20. Probing dark energy with lensing magnification in photometric surveys.

    Science.gov (United States)

    Schneider, Michael D

    2014-02-14

    I present an estimator for the angular cross correlation of two tracers of the cosmological large-scale structure that utilizes redshift information to isolate separate physical contributions. The estimator is derived by solving the Limber equation for a reweighting of the foreground tracer that nulls either clustering or lensing contributions to the cross correlation function. Applied to future photometric surveys, the estimator can enhance the measurement of gravitational lensing magnification effects to provide a competitive independent constraint on the dark energy equation of state.

  1. Study on the electrostatic prismatic spectrometer with quadrupole lenses

    International Nuclear Information System (INIS)

    Petrov, I.A.

    1975-01-01

    The mosk-up structure of electrostatic prismatic spectrometer with quadrupole lenses is described and its parameters are investigated. The gap between the electrodes of the prism is chosen to be 20 mm to ensure greater transmission. The relative angular dispersion of the prism is 4.69. The spectrometer consists of the main vacuum chamber, source chamber, and detector chamber. All parts of the spectrometer have been made from non-magnetic materials. A permalloy magnetostatic screen 1.5 mm thick serves to protect the instrument from disturbing fields, above all, the geomagnetic field. Using a three-electrode electron gun with a V-shaped tungsten cathode, which serves as an imitator for the adjustment of the spectrometer and for the determination of its parameters, have been measured the solid angle of particle acceptance by the instrument and the height of the source slit. The dependence of the spectrometer transmission on the height of the entrance slit and on the half-angle of the electron beam from the source has been obtained. An analysis of the experiments carried out indicates that the height of the source slit providing the maximum contribution to the line intensity is about 4 mm and the spectrometer transmission is close to unity at half-angle values of about 1 deg 30'. The experimental value of the instrument luminosity obtained for the source slit height and the electron divergence angle ensuring the main contribution to the line intesity is L=0.04x1x4=0.16% mm 2 with a resolving power of 1.000

  2. Laboratory simulation of Euclid-like sky images to study the impact of CCD radiation damage on weak gravitational lensing

    Science.gov (United States)

    Prod'homme, T.; Verhoeve, P.; Oosterbroek, T.; Boudin, N.; Short, A.; Kohley, R.

    2014-07-01

    Euclid is the ESA mission to map the geometry of the dark universe. It uses weak gravitational lensing, which requires the accurate measurement of galaxy shapes over a large area in the sky. Radiation damage in the 36 Charge-Coupled Devices (CCDs) composing the Euclid visible imager focal plane has already been identified as a major contributor to the weak-lensing error budget; radiation-induced charge transfer inefficiency (CTI) distorts the galaxy images and introduces a bias in the galaxy shape measurement. We designed a laboratory experiment to project Euclid-like sky images onto an irradiated Euclid CCD. In this way - and for the first time - we are able to directly assess the effect of CTI on the Euclid weak-lensing measurement free of modelling uncertainties. We present here the experiment concept, setup, and first results. The results of such an experiment provide test data critical to refine models, design and test the Euclid data processing CTI mitigation scheme, and further optimize the Euclid CCD operation.

  3. Cross-correlation of gravitational lensing from DES Science Verification data with SPT and Planck lensing

    Energy Technology Data Exchange (ETDEWEB)

    Kirk, D.; Omori, Y.; Benoit-Lévy, A.; Cawthon, R.; Chang, C.; Larsen, P.; Amara, A.; Bacon, D.; Crawford, T. M.; Dodelson, S.; Fosalba, P.; Giannantonio, T.; Holder, G.; Jain, B.; Kacprzak, T.; Lahav, O.; MacCrann, N.; Nicola, A.; Refregier, A.; Sheldon, E.; Story, K. T.; Troxel, M. A.; Vieira, J. D.; Vikram, V.; Zuntz, J.; Abbott, T. M. C.; Abdalla, F. B.; Becker, M. R.; Benson, B. A.; Bernstein, G. M.; Bernstein, R. A.; Bleem, L. E.; Bonnett, C.; Bridle, S. L.; Brooks, D.; Buckley-Geer, E.; Burke, D. L.; Capozzi, D.; Carlstrom, J. E.; Rosell, A. Carnero; Kind, M. Carrasco; Carretero, J.; Crocce, M.; Cunha, C. E.; D' Andrea, C. B.; da Costa, L. N.; Desai, S.; Diehl, H. T.; Dietrich, J. P.; Doel, P.; Eifler, T. F.; Evrard, A. E.; Flaugher, B.; Frieman, J.; Gerdes, D. W.; Goldstein, D. A.; Gruen, D.; Gruendl, R. A.; Honscheid, K.; James, D. J.; Jarvis, M.; Kent, S.; Kuehn, K.; Kuropatkin, N.; Lima, M.; March, M.; Martini, P.; Melchior, P.; Miller, C. J.; Miquel, R.; Nichol, R. C.; Ogando, R.; Plazas, A. A.; Reichardt, C. L.; Roodman, A.; Rozo, E.; Rykoff, E. S.; Sako, M.; Sanchez, E.; Scarpine, V.; Schubnell, M.; Sevilla-Noarbe, I.; Simard, G.; Smith, R. C.; Soares-Santos, M.; Sobreira, F.; Suchyta, E.; Swanson, M. E. C.; Tarle, G.; Thomas, D.; Wechsler, R. H.; Weller, J.

    2016-03-10

    We measure the cross-correlation between weak lensing of galaxy images and of the cosmic microwave background (CMB). The effects of gravitational lensing on different sources will be correlated if the lensing is caused by the same mass fluctuations. We use galaxy shape measurements from 139 deg(2) of the Dark Energy Survey (DES) Science Verification data and overlapping CMB lensing from the South Pole Telescope (SPT) and Planck. The DES source galaxies have a median redshift of z(med) similar to 0.7, while the CMB lensing kernel is broad and peaks at z similar to 2. The resulting cross-correlation is maximally sensitive to mass fluctuations at z similar to 0.44. Assuming the Planck 2015 best-fitting cosmology, the amplitude of the DESxSPT cross-power is found to be A(SPT) = 0.88 +/- 0.30 and that from DESxPlanck to be A(Planck) = 0.86 +/- 0.39, where A = 1 corresponds to the theoretical prediction. These are consistent with the expected signal and correspond to significances of 2.9 sigma and 2.2 sigma, respectively. We demonstrate that our results are robust to a number of important systematic effects including the shear measurement method, estimator choice, photo-z uncertainty and CMB lensing systematics. We calculate a value of A = 1.08 +/- 0.36 for DESxSPT when we correct the observations with a simple intrinsic alignment model. With three measurements of this cross-correlation now existing in the literature, there is not yet reliable evidence for any deviation from the expected LCDM level of cross-correlation. We provide forecasts for the expected signal-to-noise ratio of the combination of the five-year DES survey and SPT-3G.

  4. Cellular proliferation and regeneration following tissue damage. Progress report. [X radiation; rabbit lenses

    Energy Technology Data Exchange (ETDEWEB)

    Harding, C.V.

    1977-01-01

    Studies were conducted on the following research projects: effects of x radiation on rabbit lenses; DNA synthesis and mitosis in cultured lenses; serum dependency and actinomycin D sensitivity; changes in ultrastructure; injury-induced growth of vascular endothelium; corneal neovascularization following injury; and human cataractous lenses. (HLW)

  5. High Quality Liquid Crystal Tunable Lenses and Optimization with Floating Electrodes

    Science.gov (United States)

    Li, Liwei

    2013-01-01

    In addition to the display application, Liquid Crystals (LC) can be very useful in other applications such as beam steering, tunable lenses, etc. Electro-optical LC tunable lenses have been considered as an alternative to conventional glass lenses because of their ability to change their focal length with the application of a control voltage, as…

  6. Lensing of Fast Radio Bursts as a Probe of Compact Dark Matter.

    Science.gov (United States)

    Muñoz, Julian B; Kovetz, Ely D; Dai, Liang; Kamionkowski, Marc

    2016-08-26

    The possibility that part of the dark matter is made of massive compact halo objects (MACHOs) remains poorly constrained over a wide range of masses, and especially in the 20-100  M_{⊙} window. We show that strong gravitational lensing of extragalactic fast radio bursts (FRBs) by MACHOs of masses larger than ∼20  M_{⊙} would result in repeated FRBs with an observable time delay. Strong lensing of a FRB by a lens of mass M_{L} induces two images, separated by a typical time delay ∼few×(M_{L}/30  M_{⊙})  msec. Considering the expected FRB detection rate by upcoming experiments, such as canadian hydrogen intensity mapping experiment (CHIME), of 10^{4} FRBs per year, we should observe from tens to hundreds of repeated bursts yearly, if MACHOs in this window make up all the dark matter. A null search for echoes with just 10^{4} FRBs would constrain the fraction f_{DM} of dark matter in MACHOs to f_{DM}≲0.08 for M_{L}≳20  M_{⊙}.

  7. Strong Gravitational Lensing in a Brane-World Black Hole

    Science.gov (United States)

    Li, GuoPing; Cao, Biao; Feng, Zhongwen; Zu, Xiaotao

    2015-09-01

    Adopting the strong field limit approach, we investigated the strong gravitational lensing in a Brane-World black hole, which means that the strong field limit coefficients and the deflection angle in this gravitational field are obtained. With this result, it can be said with certainly that the strong gravitational lensing is related to the metric of gravitational fields closely, the cosmology parameter α and the dark matter parameter β come from the Brane-World black hole exerts a great influence on it. Comparing with the Schwarzschild-AdS spacetime and the Schwarzschild-XCMD spacetime, the parameters α, β of black holes have the similar effects on the gravitational lensing. In some way, we infer that the real gravitational fields in our universe can be described by this metric, so the results of the strong gravitational lensing in this spacetime will be more reasonable for us to observe. Finally, it has to be noticed that the influence which the parameters α, β exerted on the main observable quantities of this gravitational field is discussed.

  8. Energy-Efficient Optical Signal Processing Using Optical Time Lenses

    DEFF Research Database (Denmark)

    Oxenløwe, Leif Katsuo; Galili, Michael; Mulvad, Hans Christian Hansen

    2015-01-01

    . Combining time lenses into telescopic arrangements allows for more advanced signal processing, such as temporal or spectral compression or magnification. A spectral telescope may for instance allow for conversion of OFDM signals to DWDM-like signals, which can be separated passively, i.e. without additional...

  9. The Perspective Effect of Wide-Angle Lenses in Laparoscopes

    NARCIS (Netherlands)

    Wentink, M.; Fischer, H.; Dankelman, J.; Stassen, L.P.S.; Wieringa, P.A.

    2002-01-01

    Purpose: To evaluate the effect of perspective distortion of wide-angle lenses in laparoscopes on hand-eye coordination during endoscopic manipulation. Methods: Sixteen subjects repeatedly performed a standardized positioning task in a pelvi-trainer under two conditions. The subjects had no prior

  10. How to Measure Dark Energy with LSST's Strong Gravitational Lenses

    Science.gov (United States)

    Marshall, Philip J.; Treu, T.; Brunner, R. J.; Strong Lensing, LSST; Dark Energy Science Collaborations

    2013-01-01

    Strong gravitational lensing is sensitive to dark energy (DE) via the combinations of angular diameter distances that appear in model predictions of the lens strength. Lenses with variable sources offer the most promise: the corresponding time delay distance has recently been shown to be measurable to 5% precision. Large samples of lensed quasars and supernovae will allow internal degeneracy-breaking and so enable the most direct access to the DE parameters, while multiple source-plane, compound lens systems may provide an alternative, complementary, H0-free probe. Its wide field survey and high cadence will enable LSST to provide a sample of several thousand measured time delays, two orders of magnitude larger than the current sample, and allow an independent, competitive Stage IV DE parameter measurement to be made. However, practical problems to be solved include: lens detection (which may be very sensitive to image quality and deblender performance); image and lightcurve modelling (which could be both CPU and manual labor-intensive); obtaining and analyzing high resolution spectro-imaging follow-up data; and interpreting the whole sample of lenses in the context of the well-studied subset.

  11. Single-molecule microscopy using silicone oil immersion objective lenses

    NARCIS (Netherlands)

    Hink, M.

    2012-01-01

    Microscopy techniques capable of detecting individual molecules and providing quantitative data have the potential to offer great biological insight; however, such approaches require the efficient capture of light. Here, Mark Hink explains how the use of new silicone oil immersion objective lenses

  12. Planck-Scale Dual-Curvature Lensing and Spacetime Noncommutativity

    Directory of Open Access Journals (Sweden)

    Giovanni Amelino-Camelia

    2017-01-01

    Full Text Available It was recently realized that Planck-scale momentum-space curvature, which is expected in some approaches to the quantum-gravity problem, can produce dual-curvature lensing, a feature which mainly affects the direction of observation of particles emitted by very distant sources. Several gray areas remain in our understanding of dual-curvature lensing, including the possibility that it might be just a coordinate artifact and the possibility that it might be in some sense a by-product of the better studied dual-curvature redshift. We stress that data reported by the IceCube neutrino telescope should motivate a more vigorous effort of investigation of dual-curvature lensing, and we observe that studies of the recently proposed “ρ-Minkowski noncommutative spacetime” could be valuable from this perspective. Through a dedicated ρ-Minkowski analysis, we show that dual-curvature lensing is not merely a coordinate artifact and that it can be present even in theories without dual-curvature redshift.

  13. Characterisation of adaptive fluidic silicone-membrane lenses

    CSIR Research Space (South Africa)

    Schneider, F

    2010-03-01

    Full Text Available The authors compare the performance and optical quality of two types of adaptive fluidic silicone-membrane lenses. The membranes feature either a homogeneous thickness, or they are shaped resulting in an inhomogeneous cross-section. The lens systems...

  14. Microbiological study of disposable soft contact lenses after photorefractive keratectomy.

    Science.gov (United States)

    Dantas, P E; Nishiwaki-Dantas, M C; Ojeda, V H; Holzchuh, N; Mimica, L J

    2000-01-01

    To evaluate the bacterial contamination of bandage disposable soft contact lenses used in patients following photorefractive keratectomy (PRK) and to correlate our findings with clinical data. Forty-six patients (81 eyes) underwent PRK. Immediately after each procedure, disposable soft contact lenses were positioned with sterile forceps. After 3 days, the lenses were removed in a sterile manner, placed in sterile Eppendorf pipettes containing 8 mL of enriched brain heart infusion broth, and analyzed for microbial contamination. Seven positive cultures were found: six gram positive cocci (7.4%) and one gram negative bacillus (1.2%). There was no clinical correlation with these findings. Isolated microorganisms were similar to those described in the literature as agents of bacterial keratitis and are components of the normal ocular flora. Klebsiela pneumoniae--considered an occasional or transient flora--was the exception. All isolated microorganisms but K. pneumoniae were sensitive to most of the antibiotics tested. Our findings suggest that the risk of infectious keratitis after PRK related to soft contact lens wear for 3 days seems to be low, which may be because lenses were not manipulated by the patient during the wearing period, and the postoperative antibiotic regimen was strictly followed by patients. However, care should be taken to instruct patients in proper lens care practices to reduce the risk of bacterial keratitis in contact lens wear following PRK.

  15. Active Learning Environment with Lenses in Geometric Optics

    Science.gov (United States)

    Tural, Güner

    2015-01-01

    Geometric optics is one of the difficult topics for students within physics discipline. Students learn better via student-centered active learning environments than the teacher-centered learning environments. So this study aimed to present a guide for middle school teachers to teach lenses in geometric optics via active learning environment…

  16. UK Higher Education Viewed through the Marketization and Marketing Lenses

    Science.gov (United States)

    Nedbalová, Eva; Greenacre, Luke; Schulz, John

    2014-01-01

    This paper uses the Economic Market mechanisms and the 4P Marketing Mix as lenses to review the context of UK higher education (HE) and to explore the relationship between the market and marketing disciplines and practice. Four Economic Market mechanisms--autonomy, competition, price and information--are contrasted with the four Ps of marketing:…

  17. Disposable contact lenses vs. contact lens maintenance for extended wear.

    Science.gov (United States)

    Josephson, J E; Caffery, B E; Campbell, I; Slomovic, A R

    1990-01-01

    We compared a disposable extended wear contact lens modality with conventional extended wear over a 6-week period. To do so, we refit 31 patients who had successfully worn conventional extended wear contact lenses for more than 1 year. One eye was fit with the AcuvueR disposable contact lens, and a new extended wear lens of the type the patient had been wearing was placed on the other eye. At weekly intervals the disposable lens was discarded and a new disposable lens inserted. At the same time, the conventional lens on the fellow eye was cleaned, disinfected, and reinserted. After 6 weeks the ocular response, subjective impressions, and condition of the lenses in the two eyes were compared. Both lenses were then cultured. Three subjects had to discontinue disposable lens wear because of adverse reactions to trapped cellular debris and corneal microcysts. Although the results were not statistically significant, the Acuvue lens appeared to perform better than or equal to the conventional lens in biomicroscopic observation, visual acuity measurement, and subjective patient preference. Eighty-seven percent of patients preferred to continue with the disposable system. There were no differences found in the type or degree of microbial contamination of the lenses.

  18. Galaxy-galaxy lensing estimators and their covariance properties

    Science.gov (United States)

    Singh, Sukhdeep; Mandelbaum, Rachel; Seljak, Uroš; Slosar, Anže; Vazquez Gonzalez, Jose

    2017-11-01

    We study the covariance properties of real space correlation function estimators - primarily galaxy-shear correlations, or galaxy-galaxy lensing - using SDSS data for both shear catalogues and lenses (specifically the BOSS LOWZ sample). Using mock catalogues of lenses and sources, we disentangle the various contributions to the covariance matrix and compare them with a simple analytical model. We show that not subtracting the lensing measurement around random points from the measurement around the lens sample is equivalent to performing the measurement using the lens density field instead of the lens overdensity field. While the measurement using the lens density field is unbiased (in the absence of systematics), its error is significantly larger due to an additional term in the covariance. Therefore, this subtraction should be performed regardless of its beneficial effects on systematics. Comparing the error estimates from data and mocks for estimators that involve the overdensity, we find that the errors are dominated by the shape noise and lens clustering, which empirically estimated covariances (jackknife and standard deviation across mocks) that are consistent with theoretical estimates, and that both the connected parts of the four-point function and the supersample covariance can be neglected for the current levels of noise. While the trade-off between different terms in the covariance depends on the survey configuration (area, source number density), the diagnostics that we use in this work should be useful for future works to test their empirically determined covariances.

  19. On an illusion of superluminal velocities produced by gravitational lenses

    International Nuclear Information System (INIS)

    Ingel, L.Kh.

    1981-01-01

    It is noted that gravitational lenses, by focusing the radiation of an object, increase the angle which it subtends. This in turn produces the illusion of an increase in velocities at right angles to the line of sight. Preliminary estimates are made which indicate a rather high probability of strong distortion of the observed velocities

  20. Thermal lensing measurement from the coefficient of defocus aberration

    CSIR Research Space (South Africa)

    Bell, Teboho

    2016-03-01

    Full Text Available geometrical method to alleviate irregularities. Figure 4: Unstable plano-parallel laser resonator used to determine thermally induced lensing. Figure 3: (a) The graph of the transmitted power against the input pump power. (b) Nd: YAG cystal pumped by a...

  1. Galaxy number counts and implications for strong lensing

    NARCIS (Netherlands)

    Fassnacht, C. D.; Koopmans, L. V. E.; Wong, K. C.

    We compare galaxy number counts in Advanced Camera for Surveys (ACS) fields containing moderate-redshift (0.2 lenses with those in two control samples: (1) the first square degree of the COSMOS survey, comprising 259 ACS fields and (2) 20 ‘pure-parallel’ fields randomly

  2. The cuticular nature of corneal lenses in Drosophila melanogaster.

    Science.gov (United States)

    Stahl, Aaron L; Charlton-Perkins, Mark; Buschbeck, Elke K; Cook, Tiffany A

    2017-07-01

    The dioptric visual system relies on precisely focusing lenses that project light onto a neural retina. While the proteins that constitute the lenses of many vertebrates are relatively well characterized, less is known about the proteins that constitute invertebrate lenses, especially the lens facets in insect compound eyes. To address this question, we used mass spectrophotometry to define the major proteins that comprise the corneal lenses from the adult Drosophila melanogaster compound eye. This led to the identification of four cuticular proteins: two previously identified lens proteins, drosocrystallin and retinin, and two newly identified proteins, Cpr66D and Cpr72Ec. To determine which ommatidial cells contribute each of these proteins to the lens, we conducted in situ hybridization at 50% pupal development, a key age for lens secretion. Our results confirm previous reports that drosocrystallin and retinin are expressed in the two primary corneagenous cells-cone cells and primary pigment cells. Cpr72Ec and Cpr66D, on the other hand, are more highly expressed in higher order interommatidial pigment cells. These data suggest that the complementary expression of cuticular proteins give rise to the center vs periphery of the corneal lens facet, possibly facilitating a refractive gradient that is known to reduce spherical aberration. Moreover, these studies provide a framework for future studies aimed at understanding the cuticular basis of corneal lens function in holometabolous insect eyes.

  3. Ultraviolet radiation for the sterilization of contact lenses.

    Science.gov (United States)

    Gritz, D C; Lee, T Y; McDonnell, P J; Shih, K; Baron, N

    1990-01-01

    Two sources of ultraviolet (UV) radiation with peak wavelengths in the UV-C or UV-B ranges were compared for their ability to sterilize contact lenses infected with Pseudomonas aeruginosa, Streptococcus pneumoniae, Acanthamoeba castellani, Candida albicans, and Aspergillus niger. Also examined was the effect of prolonged UV light exposure on soft and rigid gas permeable (RGP) contact lenses. The UV-C lamp (253.7 nm, 250 mW/cm2 at 1 cm) was germicidal for all organisms within 20 minutes but caused destruction of the soft lens polymers within 6 hours of cumulative exposure. UV-C caused damage to RGP lenses in less than 100 hours. The UV-B lamp (290-310 nm, 500 mW/cm2 at 1 cm) was germicidal for all organisms tested (except Aspergillus) with a 180-minute exposure and caused less severe changes in the soft lens polymers than did the UV-C lamp, although cumulative exposure of 300 hours did substantially weaken the soft lens material. RGP materials were minimally affected by exposure to 300 hours of UV-B. Ultraviolet light is an effective germicidal agent but is injurious to soft lens polymers; its possible utility in the sterilization of RGP lenses and lens cases deserves further study.

  4. Weak Lensing by Galaxy Troughs in DES Science Verification Data

    Energy Technology Data Exchange (ETDEWEB)

    Gruen, D. [Ludwig Maximilian Univ., Munich (Germany); Max Planck Inst. for Extraterrestrial Physics, Garching (Germany). et al.

    2015-09-29

    We measure the weak lensing shear around galaxy troughs, i.e. the radial alignment of background galaxies relative to underdensities in projections of the foreground galaxy field over a wide range of redshift in Science Verification data from the Dark Energy Survey. Our detection of the shear signal is highly significant (10σ–15σ for the smallest angular scales) for troughs with the redshift range z ϵ [0.2, 0.5] of the projected galaxy field and angular diameters of 10 arcmin…1°. These measurements probe the connection between the galaxy, matter density, and convergence fields. By assuming galaxies are biased tracers of the matter density with Poissonian noise, we find agreement of our measurements with predictions in a fiducial Λ cold dark matter model. Furthermore, the prediction for the lensing signal on large trough scales is virtually independent of the details of the underlying model for the connection of galaxies and matter. Our comparison of the shear around troughs with that around cylinders with large galaxy counts is consistent with a symmetry between galaxy and matter over- and underdensities. In addition, we measure the two-point angular correlation of troughs with galaxies which, in contrast to the lensing signal, is sensitive to galaxy bias on all scales. Finally, the lensing signal of troughs and their clustering with galaxies is therefore a promising probe of the statistical properties of matter underdensities and their connection to the galaxy field.

  5. Ultraviolet radiation for the sterilization of contact lenses

    International Nuclear Information System (INIS)

    Gritz, D.C.; Lee, T.Y.; McDonnell, P.J.; Shih, K.; Baron, N.

    1990-01-01

    Two sources of ultraviolet (UV) radiation with peak wavelengths in the UV-C or UV-B ranges were compared for their ability to sterilize contact lenses infected with Pseudomonas aeruginosa, Streptococcus pneumoniae, Acanthamoeba castellani, Candida albicans, and Aspergillus niger. Also examined was the effect of prolonged UV light exposure on soft and rigid gas permeable (RGP) contact lenses. The UV-C lamp (253.7 nm, 250 mW/cm2 at 1 cm) was germicidal for all organisms within 20 minutes but caused destruction of the soft lens polymers within 6 hours of cumulative exposure. UV-C caused damage to RGP lenses in less than 100 hours. The UV-B lamp (290-310 nm, 500 mW/cm2 at 1 cm) was germicidal for all organisms tested (except Aspergillus) with a 180-minute exposure and caused less severe changes in the soft lens polymers than did the UV-C lamp, although cumulative exposure of 300 hours did substantially weaken the soft lens material. RGP materials were minimally affected by exposure to 300 hours of UV-B. Ultraviolet light is an effective germicidal agent but is injurious to soft lens polymers; its possible utility in the sterilization of RGP lenses and lens cases deserves further study

  6. Ultraviolet radiation for the sterilization of contact lenses

    Energy Technology Data Exchange (ETDEWEB)

    Gritz, D.C.; Lee, T.Y.; McDonnell, P.J.; Shih, K.; Baron, N. (Univ. of Southern California School of Medicine, Los Angeles (USA))

    1990-10-01

    Two sources of ultraviolet (UV) radiation with peak wavelengths in the UV-C or UV-B ranges were compared for their ability to sterilize contact lenses infected with Pseudomonas aeruginosa, Streptococcus pneumoniae, Acanthamoeba castellani, Candida albicans, and Aspergillus niger. Also examined was the effect of prolonged UV light exposure on soft and rigid gas permeable (RGP) contact lenses. The UV-C lamp (253.7 nm, 250 mW/cm2 at 1 cm) was germicidal for all organisms within 20 minutes but caused destruction of the soft lens polymers within 6 hours of cumulative exposure. UV-C caused damage to RGP lenses in less than 100 hours. The UV-B lamp (290-310 nm, 500 mW/cm2 at 1 cm) was germicidal for all organisms tested (except Aspergillus) with a 180-minute exposure and caused less severe changes in the soft lens polymers than did the UV-C lamp, although cumulative exposure of 300 hours did substantially weaken the soft lens material. RGP materials were minimally affected by exposure to 300 hours of UV-B. Ultraviolet light is an effective germicidal agent but is injurious to soft lens polymers; its possible utility in the sterilization of RGP lenses and lens cases deserves further study.

  7. CALCULATION AND RESEARCH OF CONTACT OPHTHALMIC DUAL APPLICATION LENSES

    Directory of Open Access Journals (Sweden)

    D. N. Cherkasova

    2015-05-01

    Full Text Available Subject of research. Algorithm for calculation of contact ophthalmic lenses for dual application has been suggested based on unified approach for their calculation. The algorithm has been tested on the composition of Goldmann ophthalmic lenses and Panfundoscope lens optical systems. Method. The condition of mutual unambiguous orientation of patient’s eye and instruments is performed at the initial calculation step by face mounting and movement of coordinate table with optical head. Then such type of patient's eye optical system model is selected that the lens would be combined with the front surface of eye cornea optical system. Pupil of patient eye is under anesthesia. At the final calculation step we determine the functions of optical lens image quality and their values based on medical and technical requirements for the components of the complex system. Main results. The algorithm for ophthalmic lenses calculation has been suggested and its correctness has been proved practically on the example of two basic models in the group of such type lenses being applied in practice as a part of complex system with ophthalmic laser coagulators. Optical calculation of Goldmann ophthalmic contact lenses and Panfundoscope is presented. The method of neutralization is optimal for Goldmann lenses. The first component in Panfundoscope operates the position of object planes whereas the second component operates the position of complex system with ophthalmocoagulator's pupils. Computer modeling of complex system "Computer model of eye-ophthalmic lens" in ZEMAX confirmed the correctness of calculation algorithm in which the criteria of diffraction image quality has been used. Application possibility of simplified computer eye model called "Reduced eye" by Verbitskiy has been demonstrated. Practical relevance. The general scientific approach to the problem of synthesis, calculation and research of complex system with contact ophthalmic lenses for diagnostics

  8. Accommodating intraocular lenses: a critical review of present and future concepts.

    Science.gov (United States)

    Menapace, R; Findl, O; Kriechbaum, K; Leydolt-Koeppl, Ch

    2007-04-01

    fibrosis by extensive capsule polishing did not enhance the functional performance. Dual optic lenses are under clinical investigation and are reported to provide a significant amount of accommodation. However, possible long-term formation of interlenticular opacifications remains to be excluded. Regarding magnet-driven active-shift lens systems, initial clinical experience has been promising. Prevention of fibrotic capsular contraction is crucial, and it has been effectively counteracted with a special capsular tension ring, or lens fixation technique, together with capsule polishing. Lens refilling has been extensively studied in the laboratory and in primates. Though it offers great potential for fully restoring accommodation, a variety of problems must be solved, such as achieving emmetropia in the relaxed state, adequate response to ciliary muscle contraction, satisfying image quality over the entire range of accommodation and sustained functioning. The key problem, however, is again after-cataract prevention. As opposed to psychophysical evaluation techniques, laser interferometry measures what shift lenses are designed to provide: axial shift on accommodative effort. While under pilocarpine some movement was recorded, no movement at all was found under near-point stimulation with any of the lenses currently marketed. In contrast, magnetic-driven active-shift lens systems carry the potential of sufficiently topping up apparent accommodation to provide for clinically useful accommodation while using conventional lens designs with proven after-cataract performance. Dual optic implants significantly increase the impact of axial optic shift. The main potential problem, however, is delayed formation of interlenticular regenerates. Lens refilling procedures offer the potential of fully restoring accommodation due to the great impact of increase in surface curvature on refractive lens power. However, various problems remain to be solved before clinical use can be envisaged

  9. Cosmological tests with strong gravitational lenses using Gaussian processes

    Science.gov (United States)

    Yennapureddy, Manoj K.; Melia, Fulvio

    2018-03-01

    Strong gravitational lenses provide source/lens distance ratios D_{obs} useful in cosmological tests. Previously, a catalog of 69 such systems was used in a one-on-one comparison between the standard model, Λ CDM, and the Rh=ct universe, which has thus far been favored by the application of model selection tools to many other kinds of data. But in that work, the use of model parametric fits to the observations could not easily distinguish between these two cosmologies, in part due to the limited measurement precision. Here, we instead use recently developed methods based on Gaussian Processes (GP), in which D_{obs} may be reconstructed directly from the data without assuming any parametric form. This approach not only smooths out the reconstructed function representing the data, but also reduces the size of the 1σ confidence regions, thereby providing greater power to discern between different models. With the current sample size, we show that analyzing strong lenses with a GP approach can definitely improve the model comparisons, producing probability differences in the range ˜ 10-30%. These results are still marginal, however, given the relatively small sample. Nonetheless, we conclude that the probability of Rh=ct being the correct cosmology is somewhat higher than that of Λ CDM, with a degree of significance that grows with the number of sources in the subsamples we consider. Future surveys will significantly grow the catalog of strong lenses and will therefore benefit considerably from the GP method we describe here. In addition, we point out that if the Rh=ct universe is eventually shown to be the correct cosmology, the lack of free parameters in the study of strong lenses should provide a remarkably powerful tool for uncovering the mass structure in lensing galaxies.

  10. Class B0631+519: Last of the Class Lenses

    Energy Technology Data Exchange (ETDEWEB)

    York, Tom; Jackson, N.; Browne, I.W.A.; Koopmans, L.V.E.; McKean, J.P.; Norbury, M.A.; Biggs, A.D.; Blandford, R.D.; de Bruyn, A.G.; Fassnacht, C.D.; Myers, S.T.; Pearson, T.J.; Phillips, P.M.; Readhead, A.C.S.; Rusin, D.; Wilkinson, P.N.; /Jodrell Bank /Kapteyn Astron. Inst., Groningen /UC, Davis /JIVE, Dwingeloo /KIPAC, Menlo Park /NFRA,

    2005-05-31

    We report the discovery of the new gravitational lens system CLASS B0631+519. Imaging with the VLA, MERLIN and the VLBA reveals a doubly-imaged flat-spectrum radio core, a doubly-imaged steep-spectrum radio lobe and possible quadruply-imaged emission from a second lobe. The maximum separation between the lensed images is 1.16 arcsec. High resolution mapping with the VLBA at 5 GHz resolves the most magnified image of the radio core into a number of sub-components spread across approximately 20 mas. No emission from the lensing galaxy or an odd image is detected down to 0.31 mJy (5{sigma}) at 8.4 GHz. Optical and near-infrared imaging with the ACS and NICMOS cameras on the HST show that there are two galaxies along the line of sight to the lensed source, as previously discovered by optical spectroscopy. We find that the foreground galaxy at z=0.0896 is a small irregular, and that the other, at z=0.6196 is a massive elliptical which appears to contribute the majority of the lensing effect. The host galaxy of the lensed source is detected in the HST near-infrared imaging as a set of arcs, which form a nearly complete Einstein ring. Mass modeling using non-parametric techniques can reproduce the near-infrared observations and indicates that the small irregular galaxy has a (localized) effect on the flux density distribution in the Einstein ring at the 5-10% level.

  11. Bibliometric Study of Scientific Research on Scleral Lenses.

    Science.gov (United States)

    Povedano-Montero, Francisco Javier; Álvarez-Peregrina, Cristina; Hidalgo Santa Cruz, Fernando; Villa-Collar, César; Sánchez Valverde, José

    2018-01-25

    To analyze the state of scientific publications in the field of scleral lenses applying a bibliometric study. The database used in this bibliometric study was SCOPUS, the largest abstract and citation database of peer-reviewed literature: scientific journals, books, and conference proceedings. Using remote download techniques, articles published between 1962 (year of first registrations) and 2015 were selected by entering the main descriptors: "scleral contact lenses" and "scleral lenses," limiting the field for the article, keywords, and abstract, linked with the OR tab. We applied the following bibliometric indicators: Price index, doubling time and annual growth rate, Price transience index, Lotka law of scientific productivity, and Bradford zones. The authors recovered 361 contributions (articles, reviews, letters to the editor, etc.) for 1962 to 2016. The distribution for five-year periods shows a significant increase in 2012 to 2016, with a growth of 222.22% in comparison with the previous period 2012 to 2016. The countries with the highest production are the United states with 135 contributions, United Kingdom with 46, and India with 19. The most productive institutions are Harvard Medical school, Boston Foundation for Sight, and Moorfields Eye Hospital National Health Service Foundation Trust. Classification of authors based on productivity is strongly concentrated in small producers, with a transient index of 59.03. The total number of authors is 891, representing a coauthor index of 2.47 for the 361 documents retrieved. The authors with the highest productivity are Kenneth W. Pullum, Perry Rosenthal, and Deborah S. Jacobs, with an h-index between 12 and 19 documents. The number of documents published on scleral lenses shows a significant increase in the last 5 years, and currently, they represent only 1.44% of all publications on contact lenses. Bibliometric studies have become essential tools for evaluating scientific activity, allowing an overview of

  12. Gravitational lensing of gravitational waves: A statistical perspective

    Science.gov (United States)

    Li, Shun-Sheng; Mao, Shude; Zhao, Yuetong; Lu, Youjun

    2018-02-01

    In this paper we study the strong gravitational lensing of gravitational waves (GWs) from a statistical perspective, with particular focus on the high frequency GWs from stellar binary black hole coalescences. These are most promising targets for ground-based detectors such as aLIGO and the proposed Einstein Telescope (ET) and can be safely treated under the geometrical optics limit for GW propagation. We perform a thorough calculation of the lensing rate, by taking account of effects caused by the ellipticity of lensing galaxies, lens environments, and magnification bias. We find that in certain GW source rate scenarios, we should be able to observe strongly lensed GW events once per year (˜1 yr-1) in the aLIGO survey at its design sensitivity; for the proposed ET survey, the rate could be as high as ˜80 yr-1. These results depend on the estimate of GW source abundance, and hence can be correspondingly modified with an improvement in our understanding of the merger rate of stellar binary black holes. We also compute the fraction of four-image lens systems in each survey, predicting it to be ˜30 percent for the aLIGO survey and ˜6 percent for the ET survey. Finally, we evaluate the possibility of missing some images due to the finite survey duration, by presenting the probability distribution of lensing time delays. We predict that this selection bias will be insignificant in future GW surveys, as most of the lens systems (˜90%) will have time delays less than ˜1 month which will be far shorter than survey durations.

  13. Gravitational lensing of gravitational waves: a statistical perspective

    Science.gov (United States)

    Li, Shun-Sheng; Mao, Shude; Zhao, Yuetong; Lu, Youjun

    2018-05-01

    In this paper, we study the strong gravitational lensing of gravitational waves (GWs) from a statistical perspective, with particular focus on the high frequency GWs from stellar binary black hole coalescences. These are most promising targets for ground-based detectors such as Advanced Laser Interferometer Gravitational Wave Observatory (aLIGO) and the proposed Einstein Telescope (ET) and can be safely treated under the geometrical optics limit for GW propagation. We perform a thorough calculation of the lensing rate, by taking account of effects caused by the ellipticity of lensing galaxies, lens environments, and magnification bias. We find that in certain GW source rate scenarios, we should be able to observe strongly lensed GW events once per year (˜1 yr-1) in the aLIGO survey at its design sensitivity; for the proposed ET survey, the rate could be as high as ˜80 yr-1. These results depend on the estimate of GW source abundance, and hence can be correspondingly modified with an improvement in our understanding of the merger rate of stellar binary black holes. We also compute the fraction of four-image lens systems in each survey, predicting it to be ˜30 per cent for the aLIGO survey and ˜6 per cent for the ET survey. Finally, we evaluate the possibility of missing some images due to the finite survey duration, by presenting the probability distribution of lensing time delays. We predict that this selection bias will be insignificant in future GW surveys, as most of the lens systems ({˜ } 90{per cent}) will have time delays less than ˜1 month, which will be far shorter than survey durations.

  14. Predicting weak lensing statistics from halo mass reconstructions - Final Paper

    Energy Technology Data Exchange (ETDEWEB)

    Everett, Spencer [SLAC National Accelerator Lab., Menlo Park, CA (United States)

    2015-08-20

    As dark matter does not absorb or emit light, its distribution in the universe must be inferred through indirect effects such as the gravitational lensing of distant galaxies. While most sources are only weakly lensed, the systematic alignment of background galaxies around a foreground lens can constrain the mass of the lens which is largely in the form of dark matter. In this paper, I have implemented a framework to reconstruct all of the mass along lines of sight using a best-case dark matter halo model in which the halo mass is known. This framework is then used to make predictions of the weak lensing of 3,240 generated source galaxies through a 324 arcmin² field of the Millennium Simulation. The lensed source ellipticities are characterized by the ellipticity-ellipticity and galaxy-mass correlation functions and compared to the same statistic for the intrinsic and ray-traced ellipticities. In the ellipticity-ellipticity correlation function, I and that the framework systematically under predicts the shear power by an average factor of 2.2 and fails to capture correlation from dark matter structure at scales larger than 1 arcminute. The model predicted galaxy-mass correlation function is in agreement with the ray-traced statistic from scales 0.2 to 0.7 arcminutes, but systematically underpredicts shear power at scales larger than 0.7 arcminutes by an average factor of 1.2. Optimization of the framework code has reduced the mean CPU time per lensing prediction by 70% to 24 ± 5 ms. Physical and computational shortcomings of the framework are discussed, as well as potential improvements for upcoming work.

  15. Multipole lenses with implicit poles and with harmonic distribution of current density in a coil

    International Nuclear Information System (INIS)

    Skachkov, V.S.

    1984-01-01

    General theory of the multipole lense with implicit poles is presented. The thickness of lense coil is finite. Current density distribution in the coil cross section is harmonic in the azimuth direction and arbitrary in the radial one. The calculation of yoke contribution in the lence field is given. Two particular lense variants differing from each other in the method of current density radial distribution are considered and necessary calculated relations for the lense with and without yoke ar presented. A comparative analysis of physical and technological peculiarities of these lenses is performed

  16. Omni-focal refractive focus correction technology as a substitute for bi/multi-focal intraocular lenses, contact lenses, and spectacles

    Science.gov (United States)

    Ben Yaish, Shai; Zlotnik, Alex; Raveh, Ido; Yehezkel, Oren; Belkin, Michael; Lahav, Karen; Zalevsky, Zeev

    2009-02-01

    We present novel technology for extension in depth of focus of imaging lenses for use in ophthalmic lenses correcting myopia, hyperopia with regular/irregular astigmatism and presbyopia. This technology produces continuous focus without appreciable loss of energy. It is incorporated as a coating or engraving on the surface for spectacles, contact or intraocular lenses. It was fabricated and tested in simulations and in clinical trials. From the various testing this technology seems to provide a satisfactory single-lens solution. Obtained performance is apparently better than those of existing multi/bifocal lenses and it is modular enough to provide solution to various ophthalmic applications.

  17. A CFH12k lensing survey of X-ray luminous galaxy clusters - II. Weak lensing analysis and global correlations

    NARCIS (Netherlands)

    Bardeau, S.; Soucail, G.; Kneib, J.-P.; Czoske, O.; Ebeling, H.; Hudelot, P.; Smail, I.; Smith, G. P.

    Aims. We present a wide-field multi-color survey of a homogeneous sample of eleven clusters of galaxies for which we measure total masses and mass distributions from weak lensing. This sample, spanning a small range in both X-ray luminosity and redshift, is ideally suited to determining the

  18. Clinical study of two kinds of bandage contact lenses after laser-assisted subepithelial keratectomy

    Directory of Open Access Journals (Sweden)

    Wan-Ting Zhang

    2016-07-01

    Full Text Available AIM: To investigate the clinical safety and effectiveness of the two kind of bandage contact lenses: Senofilcon A(Johnson & Johnson Acuvue Oasysand Balafilcon A(Bausch& Lomb pure visionafter laser-assisted subepithelial keratectomy(LASEK. METHODS: Thirty-eight patients(76 eyeswho had undergone the LASEK were divided into two groups. One group of patients wore Balafilcon A, the other group of patients fitted with Senofilcon A. The lenses were worn continuously for 7d. This was a seven-day experience and the patients scored for the symptom of the eyes(sore eyes, foreign body sensation and tearingon the third day and the seventh day. Both of the two groups of patients taken off the soft contact lens on the seventh day and let their vision and corneal staining checked.RESULTS: The symptoms of eye sore and tearing of the two groups patients were different. The patients who wore the Senofilcon A were better. The pain of eyes were also different at 3 and 7d after surgeries(Z=-4.146, P=0.000; Z=-2.814, P=0.005. The difference on tearing between the two groups at 3 and 7d after surgeries were significant(Z=-2.309, P=0.021; Z=-3.276, P=0.001. There was no difference on sensation of dryness between the two groups at 3 and 7d after surgeries(Z=-0.447, P=0.655; Z=-0.966, P=0.334. After the lenses were taken off, the visual acuity of patients wearing Senofilcon A was better(t=3.800, P=0.001; corneal staining showed limited spots in 1-2 quadrants with significant difference(Z=-2.384,P=0.017. CONCLUSION: The Senofilcon A(Johnson & Johnson Acuvue Oasysand Balafilcon A(Bausch& Lomb pure visionbandage contact lenses are safe and effective after LASEK, and the former is better than the latter in epithelial regeneration.

  19. Adherence of cysts and trophozoites of Acanthamoeba to unworn rigid gas permeable and soft contact lenses.

    Science.gov (United States)

    Sharma, S; Ramachandran, L; Rao, G N

    1995-10-01

    Contact lens related Acanthamoeba keratitis has been more often associated with the use of soft contact lenses than with the use of rigid gas permeable (RGP) contact lenses. We studied the adherence of Acanthamoeba cysts and trophozoites to unworn RGP (silicone acrylate and fluoropolymer) and low and high water content soft contact lenses marketed in India. A human corneal isolate of Acanthamoeba polyphaga suspended in saline (1 x 10(5) amoebae/mL) was used. Lens segments were exposed to A. polyphaga cysts or trophozoites with or without shaking. After exposure for zero to 7 hours, lenses were either washed or not washed and the adherence was determined using light microscopy and a hemocytometer (per square millimeter of the lens). Both cysts and trophozoites immediately adhered to all four types of lenses. Adhesion increased with an increase in exposure time. The number of adherent cysts and trophozoites was higher (P = 0.043-0.0003) in the unwashed group of lenses at all exposure times for all lenses. Among washed groups, adherence was greatest with RGP silicone acrylate and high water content soft lenses. Trophozoites of Acanthamoeba showed greater adherence to RGP lenses, whereas cysts showed greater adherence to high water content soft lenses. Shaking did not have a significant effect on adherence. Adhesion of Acanthamoeba to contact lenses may play an important role in the pathogenesis of Acanthamoeba keratitis.

  20. Contact lenses purchased over the internet place individuals potentially at risk for harmful eye care practices.

    Science.gov (United States)

    Fogel, Joshua; Zidile, Chaya

    2008-01-01

    Individuals are increasingly purchasing contact lenses over the Internet. No studies exist regarding Internet purchase of contact lenses and eye care health practices. One hundred fifty-one college students were surveyed regarding contact lenses purchase category (doctor's office, store, Internet). Pearson chi-square analyses compared purchase category with responses regarding U.S. Food and Drug Administration (FDA) recommendations for purchasing contact lenses online. Analysis of variance compared contact lenses purchase category with the Time Pressure Scale (TPS). Also, correlation analyses compared the TPS with Internet eye-health statements. Contact lens purchase categories included doctor's office (43.0%), store (55.0%), and Internet (22.5%), with individuals purchasing at multiple venues. With regard to the FDA recommendations, those who purchased contact lenses at a doctor's office more often adhered to the recommendations, whereas those who purchased contact lenses at a store or the Internet did so less often. Those who purchased contact lenses over the Internet had significantly higher TPS scores. In addition, higher TPS scores were significantly correlated with various statements regarding the Internet. Those who purchase contact lenses via the Internet or store do not follow a number of FDA contact lenses recommendations. Also, those with higher TPS scores trust possible non-evidence-based contact lenses Internet information. Implications with regard to the Fairness to Contact Lens Consumers Act are discussed.

  1. Robust forecasts on fundamental physics from the foreground-obscured, gravitationally-lensed CMB polarization

    Energy Technology Data Exchange (ETDEWEB)

    Errard, Josquin [Sorbonne Universités, Institut Lagrange de Paris (ILP), 98 bis Boulevard Arago, 75014 Paris (France); Feeney, Stephen M.; Jaffe, Andrew H. [Department of Physics, Blackett Laboratory, Imperial College London, Prince Consort Road, London SW7 2AZ (United Kingdom); Peiris, Hiranya V., E-mail: josquin.errard@lpnhe.in2p3.fr, E-mail: s.feeney@imperial.ac.uk, E-mail: h.peiris@ucl.ac.uk, E-mail: a.jaffe@imperial.ac.uk [Department of Physics and Astronomy, University College London, Gower Street, London WC1E 6BT (United Kingdom)

    2016-03-01

    Recent results from the BICEP, Keck Array and Planck Collaborations demonstrate that Galactic foregrounds are an unavoidable obstacle in the search for evidence of inflationary gravitational waves in the cosmic microwave background (CMB) polarization. Beyond the foregrounds, the effect of lensing by intervening large-scale structure further obscures all but the strongest inflationary signals permitted by current data. With a plethora of ongoing and upcoming experiments aiming to measure these signatures, careful and self-consistent consideration of experiments' foreground- and lensing-removal capabilities is critical in obtaining credible forecasts of their performance. We investigate the capabilities of instruments such as Advanced ACTPol, BICEP3 and Keck Array, CLASS, EBEX10K, PIPER, Simons Array, SPT-3G and SPIDER, and projects as COrE+, LiteBIRD-ext, PIXIE and Stage IV, to clean contamination due to polarized synchrotron and dust from raw multi-frequency data, and remove lensing from the resulting co-added CMB maps (either using iterative CMB-only techniques or through cross-correlation with external data). Incorporating these effects, we present forecasts for the constraining power of these experiments in terms of inflationary physics, the neutrino sector, and dark energy parameters. Made publicly available through an online interface, this tool enables the next generation of CMB experiments to foreground-proof their designs, optimize their frequency coverage to maximize scientific output, and determine where cross-experimental collaboration would be most beneficial. We find that analyzing data from ground, balloon and space instruments in complementary combinations can significantly improve component separation performance, delensing, and cosmological constraints over individual datasets. In particular, we find that a combination of post-2020 ground- and space-based experiments could achieve constraints such as σ(r)∼1.3×10{sup −4}, σ(n{sub t})∼0

  2. Robust forecasts on fundamental physics from the foreground-obscured, gravitationally-lensed CMB polarization

    Science.gov (United States)

    Errard, Josquin; Feeney, Stephen M.; Peiris, Hiranya V.; Jaffe, Andrew H.

    2016-03-01

    Recent results from the BICEP, Keck Array and Planck Collaborations demonstrate that Galactic foregrounds are an unavoidable obstacle in the search for evidence of inflationary gravitational waves in the cosmic microwave background (CMB) polarization. Beyond the foregrounds, the effect of lensing by intervening large-scale structure further obscures all but the strongest inflationary signals permitted by current data. With a plethora of ongoing and upcoming experiments aiming to measure these signatures, careful and self-consistent consideration of experiments' foreground- and lensing-removal capabilities is critical in obtaining credible forecasts of their performance. We investigate the capabilities of instruments such as Advanced ACTPol, BICEP3 and Keck Array, CLASS, EBEX10K, PIPER, Simons Array, SPT-3G and SPIDER, and projects as COrE+, LiteBIRD-ext, PIXIE and Stage IV, to clean contamination due to polarized synchrotron and dust from raw multi-frequency data, and remove lensing from the resulting co-added CMB maps (either using iterative CMB-only techniques or through cross-correlation with external data). Incorporating these effects, we present forecasts for the constraining power of these experiments in terms of inflationary physics, the neutrino sector, and dark energy parameters. Made publicly available through an online interface, this tool enables the next generation of CMB experiments to foreground-proof their designs, optimize their frequency coverage to maximize scientific output, and determine where cross-experimental collaboration would be most beneficial. We find that analyzing data from ground, balloon and space instruments in complementary combinations can significantly improve component separation performance, delensing, and cosmological constraints over individual datasets. In particular, we find that a combination of post-2020 ground- and space-based experiments could achieve constraints such as σ(r)~1.3×10-4, σ(nt)~0.03, σ( ns )~1.8×10

  3. Planck 2013 results. XVII. Gravitational lensing by large-scale structure

    CERN Document Server

    Ade, P.A.R.; Armitage-Caplan, C.; Arnaud, M.; Ashdown, M.; Atrio-Barandela, F.; Aumont, J.; Baccigalupi, C.; Banday, A.J.; Barreiro, R.B.; Bartlett, J.G.; Basak, S.; Battaner, E.; Benabed, K.; Benoit, A.; Benoit-Levy, A.; Bernard, J.P.; Bersanelli, M.; Bielewicz, P.; Bobin, J.; Bock, J.J.; Bonaldi, A.; Bonavera, L.; Bond, J.R.; Borrill, J.; Bouchet, F.R.; Bridges, M.; Bucher, M.; Burigana, C.; Butler, R.C.; Cardoso, J.F.; Catalano, A.; Challinor, A.; Chamballu, A.; Chiang, L.Y.; Chiang, H.C.; Christensen, P.R.; Church, S.; Clements, D.L.; Colombi, S.; Colombo, L.P.L.; Couchot, F.; Coulais, A.; Crill, B.P.; Curto, A.; Cuttaia, F.; Danese, L.; Davies, R.D.; Davis, R.J.; de Bernardis, P.; de Rosa, A.; de Zotti, G.; Dechelette, T.; Delabrouille, J.; Delouis, J.M.; Desert, F.X.; Dickinson, C.; Diego, J.M.; Dole, H.; Donzelli, S.; Dore, O.; Douspis, M.; Dunkley, J.; Dupac, X.; Efstathiou, G.; Ensslin, T.A.; Eriksen, H.K.; Finelli, F.; Forni, O.; Frailis, M.; Franceschi, E.; Galeotta, S.; Ganga, K.; Giard, M.; Giardino, G.; Giraud-Heraud, Y.; Gonzalez-Nuevo, J.; Gorski, K.M.; Gratton, S.; Gregorio, A.; Gruppuso, A.; Gudmundsson, J.E.; Hansen, F.K.; Hanson, D.; Harrison, D.; Henrot-Versille, S.; Hernandez-Monteagudo, C.; Herranz, D.; Hildebrandt, S.R.; Hivon, E.; Ho, S.; Hobson, M.; Holmes, W.A.; Hornstrup, A.; Hovest, W.; Huffenberger, K.M.; Jaffe, T.R.; Jaffe, A.H.; Jones, W.C.; Juvela, M.; Keihanen, E.; Keskitalo, R.; Kisner, T.S.; Kneissl, R.; Knoche, J.; Knox, L.; Kunz, M.; Kurki-Suonio, H.; Lagache, G.; Lahteenmaki, A.; Lamarre, J.M.; Lasenby, A.; Laureijs, R.J.; Lavabre, A.; Lawrence, C.R.; Leahy, J.P.; Leonardi, R.; Leon-Tavares, J.; Lesgourgues, J.; Lewis, A.; Liguori, M.; Lilje, P.B.; Linden-Vornle, M.; Lopez-Caniego, M.; Lubin, P.M.; Macias-Perez, J.F.; Maffei, B.; Maino, D.; Mandolesi, N.; Mangilli, A.; Maris, M.; Marshall, D.J.; Martin, P.G.; Martinez-Gonzalez, E.; Masi, S.; Matarrese, S.; Matthai, F.; Mazzotta, P.; Melchiorri, A.; Mendes, L.; Mennella, A.; Migliaccio, M.; Mitra, S.; Miville-Deschenes, M.A.; Moneti, A.; Montier, L.; Morgante, G.; Mortlock, D.; Moss, A.; Munshi, D.; Naselsky, P.; Nati, F.; Natoli, P.; Netterfield, C.B.; Norgaard-Nielsen, H.U.; Noviello, F.; Novikov, D.; Novikov, I.; Osborne, S.; Oxborrow, C.A.; Paci, F.; Pagano, L.; Pajot, F.; Paoletti, D.; Partridge, B.; Pasian, F.; Patanchon, G.; Perdereau, O.; Perotto, L.; Perrotta, F.; Piacentini, F.; Piat, M.; Pierpaoli, E.; Pietrobon, D.; Plaszczynski, S.; Pointecouteau, E.; Polenta, G.; Ponthieu, N.; Popa, L.; Poutanen, T.; Pratt, G.W.; Prezeau, G.; Prunet, S.; Puget, J.L.; Pullen, A.R.; Rachen, J.P.; Rebolo, R.; Reinecke, M.; Remazeilles, M.; Renault, C.; Ricciardi, S.; Riller, T.; Ristorcelli, I.; Rocha, G.; Rosset, C.; Roudier, G.; Rowan-Robinson, M.; Rubino-Martin, J.A.; Rusholme, B.; Sandri, M.; Santos, D.; Savini, G.; Scott, D.; Seiffert, M.D.; Shellard, E.P.S.; Spencer, L.D.; Starck, J.L.; Stolyarov, V.; Stompor, R.; Sudiwala, R.; Sunyaev, R.; Sureau, F.; Sutton, D.; Suur-Uski, A.S.; Sygnet, J.F.; Tauber, J.A.; Tavagnacco, D.; Terenzi, L.; Toffolatti, L.; Tomasi, M.; Tristram, M.; Tucci, M.; Tuovinen, J.; Umana, G.; Valenziano, L.; Valiviita, J.; Van Tent, B.; Vielva, P.; Villa, F.; Vittorio, N.; Wade, L.A.; Wandelt, B.D.; White, M.; White, S.D.M.; Yvon, D.; Zacchei, A.; Zonca, A.

    2014-01-01

    On the arcminute angular scales probed by Planck, the CMB anisotropies are gently perturbed by gravitational lensing. Here we present a detailed study of this effect, detecting lensing independently in the 100, 143, and 217GHz frequency bands with an overall significance of greater than 25sigma. We use the temperature-gradient correlations induced by lensing to reconstruct a (noisy) map of the CMB lensing potential, which provides an integrated measure of the mass distribution back to the CMB last-scattering surface. Our lensing potential map is significantly correlated with other tracers of mass, a fact which we demonstrate using several representative tracers of large-scale structure. We estimate the power spectrum of the lensing potential, finding generally good agreement with expectations from the best-fitting LCDM model for the Planck temperature power spectrum, showing that this measurement at z=1100 correctly predicts the properties of the lower-redshift, later-time structures which source the lensing ...

  4. Graphical user interfaces for teaching and design of GRIN lenses in optical interconnections

    International Nuclear Information System (INIS)

    Gómez-Varela, A I; Bao-Varela, C

    2015-01-01

    The use of graphical user interfaces (GUIs) enables the implementation of practical teaching methodologies to make the comprehension of a given subject easier. GUIs have become common tools in science and engineering education, where very often, the practical implementation of experiences in a laboratory involves much equipment and many people; they are an efficient and inexpensive solution to the lack of resources. The aim of this work is to provide primarily physics and engineering students with a series of GUIs to teach some configurations in optical communications using gradient-index (GRIN) lenses. The reported GUIs are intended to perform a complementary role in education as part of a ‘virtual lab’ to supplement theoretical and practical sessions and to reinforce the knowledge acquired by the students. In this regard, a series of GUIs to teach and research the implementation of GRIN lenses in optical communications applications (including a GRIN light deflector and a beam-size controller, a GRIN fibre lens for fibre-coupling purposes, planar interconnectors, and an anamorphic self-focusing lens to correct astigmatism in laser diodes) was designed using the environment GUIDE developed by MATLAB. Numerical examples using available commercial GRIN lens parameter values are presented. (paper)

  5. Graphical user interfaces for teaching and design of GRIN lenses in optical interconnections

    Science.gov (United States)

    Gómez-Varela, A. I.; Bao-Varela, C.

    2015-05-01

    The use of graphical user interfaces (GUIs) enables the implementation of practical teaching methodologies to make the comprehension of a given subject easier. GUIs have become common tools in science and engineering education, where very often, the practical implementation of experiences in a laboratory involves much equipment and many people; they are an efficient and inexpensive solution to the lack of resources. The aim of this work is to provide primarily physics and engineering students with a series of GUIs to teach some configurations in optical communications using gradient-index (GRIN) lenses. The reported GUIs are intended to perform a complementary role in education as part of a ‘virtual lab’ to supplement theoretical and practical sessions and to reinforce the knowledge acquired by the students. In this regard, a series of GUIs to teach and research the implementation of GRIN lenses in optical communications applications (including a GRIN light deflector and a beam-size controller, a GRIN fibre lens for fibre-coupling purposes, planar interconnectors, and an anamorphic self-focusing lens to correct astigmatism in laser diodes) was designed using the environment GUIDE developed by MATLAB. Numerical examples using available commercial GRIN lens parameter values are presented.

  6. Conceptual design of hollow electron lenses for beam halo control in the Large Hadron Collider

    Energy Technology Data Exchange (ETDEWEB)

    Stancari, Giulio [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Previtali, Valentina [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Valishev, Alexander [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Bruce, Roderik [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Redaelli, Stefano [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Rossi, Adriana [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Salvachua Ferrando, Belen [European Organization for Nuclear Research (CERN), Geneva (Switzerland)

    2014-06-26

    Collimation with hollow electron beams is a technique for halo control in high-power hadron beams. It is based on an electron beam (possibly pulsed or modulated in intensity) guided by strong axial magnetic fields which overlaps with the circulating beam in a short section of the ring. The concept was tested experimentally at the Fermilab Tevatron collider using a hollow electron gun installed in one of the Tevatron electron lenses. We are proposing a conceptual design for applying this technique to the Large Hadron Collider at CERN. A prototype hollow electron gun for the LHC was built and tested. The expected performance of the hollow electron beam collimator was based on Tevatron experiments and on numerical tracking simulations. Halo removal rates and enhancements of halo diffusivity were estimated as a function of beam and lattice parameters. Proton beam core lifetimes and emittance growth rates were checked to ensure that undesired effects were suppressed. Hardware specifications were based on the Tevatron devices and on preliminary engineering integration studies in the LHC machine. Required resources and a possible timeline were also outlined, together with a brief discussion of alternative halo-removal schemes and of other possible uses of electron lenses to improve the performance of the LHC.

  7. Weak gravitational lensing systematic errors in the dark energy survey

    Science.gov (United States)

    Plazas, Andres Alejandro

    Dark energy is one of the most important unsolved problems in modern Physics, and weak gravitational lensing (WL) by mass structures along the line of sight ("cosmic shear") is a promising technique to learn more about its nature. However, WL is subject to numerous systematic errors which induce biases in measured cosmological parameters and prevent the development of its full potential. In this thesis, we advance the understanding of WL systematics in the context of the Dark Energy Survey (DES). We develop a testing suite to assess the performance of the shapelet-based DES WL measurement pipeline. We determine that the measurement bias of the parameters of our Point Spread Function (PSF) model scales as (S/N )-2, implying that a PSF S/N > 75 is needed to satisfy DES requirements. PSF anisotropy suppression also satisfies the requirements for source galaxies with S/N ≳ 45. For low-noise, marginally-resolved exponential galaxies, the shear calibration errors are up to about 0.06% (for shear values ≲ 0.075). Galaxies with S/N ≳ 75 present about 1% errors, sufficient for first-year DES data. However, more work is needed to satisfy full-area DES requirements, especially in the high-noise regime. We then implement tests to validate the high accuracy of the map between pixel coordinates and sky coordinates (astrometric solution), which is crucial to detect the required number of galaxies for WL in stacked images. We also study the effect of atmospheric dispersion on cosmic shear experiments such as DES and the Large Synoptic Survey Telescope (LSST) in the four griz bands. For DES (LSST), we find systematics in the g and r (g, r, and i) bands that are larger than required. We find that a simple linear correction in galaxy color is accurate enough to reduce dispersion shear systematics to insignificant levels in the r ( i) band for DES (LSST). More complex corrections will likely reduce the systematic cosmic-shear errors below statistical errors for LSST r band

  8. The DES Science Verification Weak Lensing Shear Catalogs

    International Nuclear Information System (INIS)

    Jarvis, M.

    2016-01-01

    We present weak lensing shear catalogs for 139 square degrees of data taken during the Science Verification (SV) time for the new Dark Energy Camera (DECam) being used for the Dark Energy Survey (DES). We describe our object selection, point spread function estimation and shear measurement procedures using two independent shear pipelines, IM3SHAPE and NGMIX, which produce catalogs of 2.12 million and 3.44 million galaxies respectively. We also detail a set of null tests for the shear measurements and find that they pass the requirements for systematic errors at the level necessary for weak lensing science applications using the SV data. Furthermore, we discuss some of the planned algorithmic improvements that will be necessary to produce sufficiently accurate shear catalogs for the full 5-year DES, which is expected to cover 5000 square degrees

  9. Thermal lensing compensation for AIGO high optical power test facility

    International Nuclear Information System (INIS)

    Degallaix, Jerome; Zhao Chunnong; Ju Li; Blair, David

    2004-01-01

    We present finite element modelling of thermal lensing occurring in an interferometer test mass. Our simulations include the thermo-optic effect and mechanical expansion of the optics. For the High Optical Power Test Facility (HOPTF) operated by the Australian International Gravitational Observatory (AIGO), the optical path length measured across the laser beam radius is 45 nm for 1.2 W absorbed power for the input sapphire test mass. The AIGO thermal lens is much stronger than the one in Advanced LIGO and will degrade the interferometer performance. Direct thermal compensation and the use of an external compensation plate were investigated to minimize thermal lensing consequences in the interferometer. For the AIGO situation, a fused silica external plate is the most practical solution to correct thermally induced wavefront distortions. The compensation plate requires lower thermal power than direct compensation and does not increase the test mass temperature

  10. Stress-Strain Measurements of Semi-Aquatic Snake Lenses

    Science.gov (United States)

    Lama, Nisha; Norwood, David, , Dr.; Fontenot, Cliff, , Dr.; Wallace, Addison; Koduri, Mahitha; Allain, Rhett, , Dr.

    It is of interest to understand the mechanism by which semi-aquatic maintain visual acuity when moving from land to underwater. Toward that end, we are interested in the mechanical properties of snake lenses and how this might affect the ability of snakes to deform the lens and thus alter the lens power. In this presentation, we will present data taken with a force sensor and a rotary motion sensor to measure, in one shot, force versus displacement, from which we estimate mechanical properties of stress and strain of the eye lens of a water snake. We will compare the results from lenses freshly removed from snake to those that have been stored. More importantly though, we will compare results from one species of semi-aquatic snakes to the other species of interest

  11. Weak gravitational lensing towards high-precision cosmology

    International Nuclear Information System (INIS)

    Berge, Joel

    2007-01-01

    This thesis aims at studying weak gravitational lensing as a tool for high-precision cosmology. We first present the development and validation of a precise and accurate tool for measuring gravitational shear, based on the shapelets formalism. We then use shapelets on real images for the first time, we analyze CFHTLS images, and combine them with XMM-LSS data. We measure the normalisation of the density fluctuations power spectrum σ 8 , and the one of the mass-temperature relation for galaxy clusters. The analysis of the Hubble space telescope COSMOS field confirms our σ 8 measurement and introduces tomography. Finally, aiming at optimizing future surveys, we compare the individual and combined merits of cluster counts and power spectrum tomography. Our results demonstrate that next generation surveys will allow weak lensing to yield its full potential in the high-precision cosmology era. (author) [fr

  12. Precision cosmology from future lensed gravitational wave and electromagnetic signals.

    Science.gov (United States)

    Liao, Kai; Fan, Xi-Long; Ding, Xuheng; Biesiada, Marek; Zhu, Zong-Hong

    2017-10-27

    The standard siren approach of gravitational wave cosmology appeals to the direct luminosity distance estimation through the waveform signals from inspiralling double compact binaries, especially those with electromagnetic counterparts providing redshifts. It is limited by the calibration uncertainties in strain amplitude and relies on the fine details of the waveform. The Einstein telescope is expected to produce 10 4 -10 5 gravitational wave detections per year, 50-100 of which will be lensed. Here, we report a waveform-independent strategy to achieve precise cosmography by combining the accurately measured time delays from strongly lensed gravitational wave signals with the images and redshifts observed in the electromagnetic domain. We demonstrate that just 10 such systems can provide a Hubble constant uncertainty of 0.68% for a flat lambda cold dark matter universe in the era of third-generation ground-based detectors.

  13. Gravitational Lensing as a Probe of Cold Dark Matter Subhalos

    Directory of Open Access Journals (Sweden)

    Erik Zackrisson

    2010-01-01

    Full Text Available In the cold dark matter scenario, dark matter halos are assembled hierarchically from smaller subunits. Some of these subunits are disrupted during the merging process, whereas others survive temporarily in the form of subhalos. A long-standing problem with this picture is that the number of subhalos predicted by simulations exceeds the number of luminous dwarf galaxies seen in the vicinity of large galaxies like the Milky Way. Many of the subhalos must therefore have remained dark or very faint. If cold dark matter subhalos are as common as predicted, gravitational lensing may in principle offer a promising route to detection. In this paper, we describe the many ways through which lensing by subhalos can manifest itself, and summarize the results from current efforts to constrain the properties of cold dark matter subhalos using such effects.

  14. Experimental studies of stable confined electron clouds using Gabor lenses

    CERN Document Server

    Meusel, O.; Glaeser, B.; Schulte, K.

    2013-04-22

    Based on the idea of D. Gabor [1] space charge lenses are under investigation to be a powerful focussing device for intense ion beams. A stable confined electron column is used to provide strong radially symmetric electrostatic focussing, e.g. for positively charged ion beams. The advantages of Gabor lenses are a mass independent focussing strength, space charge compensation of the ion beam and reduced magnetic or electric fields compared to conventional focussing devices. Collective phenomena of the electron cloud result in aberrations and emittance growth of the ion beam. The knowledge of the behaviour of the electron cloud prevents a decrease of the beam brilliance. Numerical models developed to describe the electron confinement and dynamics within a Gabor lens help to understand the interaction of the ion beam with the electron column and show the causes of non-neutral plasma instabilities. The diagnosis of the electron cloud properties helps to evaluate the numerical models and to investigate the influen...

  15. Cross-correlation of gravitational lensing from DES Science Verification data with SPT and Planck lensing

    Energy Technology Data Exchange (ETDEWEB)

    Kirk, D.; Omori, Y.; Benoit-Lévy, A.; Cawthon, R.; Chang, C.; Larsen, P.; Amara, A.; Bacon, D.; Crawford, T. M.; Dodelson, S.; Fosalba, P.; Giannantonio, T.; Holder, G.; Jain, B.; Kacprzak, T.; Lahav, O.; MacCrann, N.; Nicola, A.; Refregier, A.; Sheldon, E.; Story, K. T.; Troxel, M. A.; Vieira, J. D.; Vikram, V.; Zuntz, J.; Abbott, T. M. C.; Abdalla, F. B.; Becker, M. R.; Benson, B. A.; Bernstein, G. M.; Bernstein, R. A.; Bleem, L. E.; Bonnett, C.; Bridle, S. L.; Brooks, D.; Buckley-Geer, E.; Burke, D. L.; Capozzi, D.; Carlstrom, J. E.; Rosell, A. Carnero; Kind, M. Carrasco; Carretero, J.; Crocce, M.; Cunha, C. E.; D' Andrea, C. B.; da Costa, L. N.; Desai, S.; Diehl, H. T.; Dietrich, J. P.; Doel, P.; Eifler, T. F.; Evrard, A. E.; Flaugher, B.; Frieman, J.; Gerdes, D. W.; Goldstein, D. A.; Gruen, D.; Gruendl, R. A.; Honscheid, K.; James, D. J.; Jarvis, M.; Kent, S.; Kuehn, K.; Kuropatkin, N.; Lima, M.; March, M.; Martini, P.; Melchior, P.; Miller, C. J.; Miquel, R.; Nichol, R. C.; Ogando, R.; Plazas, A. A.; Reichardt, C. L.; Roodman, A.; Rozo, E.; Rykoff, E. S.; Sako, M.; Sanchez, E.; Scarpine, V.; Schubnell, M.; Sevilla-Noarbe, I.; Simard, G.; Smith, R. C.; Soares-Santos, M.; Sobreira, F.; Suchyta, E.; Swanson, M. E. C.; Tarle, G.; Thomas, D.; Wechsler, R. H.; Weller, J.

    2016-03-10

    We measure the cross-correlation between weak lensing of galaxy images and of the cosmic microwave background (CMB). The effects of gravitational lensing on different sources will be correlated if the lensing is caused by the same mass fluctuations. We use galaxy shape measurements from 139 deg$^{2}$ of the Dark Energy Survey (DES) Science Verification data and overlapping CMB lensing from the South Pole Telescope (SPT) and Planck. The DES source galaxies have a median redshift of $z_{\\rm med} {\\sim} 0.7$, while the CMB lensing kernel is broad and peaks at $z{\\sim}2$. The resulting cross-correlation is maximally sensitive to mass fluctuations at $z{\\sim}0.44$. Assuming the Planck 2015 best-fit cosmology, the amplitude of the DES$\\times$SPT cross-power is found to be $A = 0.88 \\pm 0.30$ and that from DES$\\times$Planck to be $A = 0.86 \\pm 0.39$, where $A=1$ corresponds to the theoretical prediction. These are consistent with the expected signal and correspond to significances of $2.9 \\sigma$ and $2.2 \\sigma$ respectively. We demonstrate that our results are robust to a number of important systematic effects including the shear measurement method, estimator choice, photometric redshift uncertainty and CMB lensing systematics. Significant intrinsic alignment of galaxy shapes would increase the cross-correlation signal inferred from the data; we calculate a value of $A = 1.08 \\pm 0.36$ for DES$\\times$SPT when we correct the observations with a simple IA model. With three measurements of this cross-correlation now existing in the literature, there is not yet reliable evidence for any deviation from the expected LCDM level of cross-correlation, given the size of the statistical uncertainties and the significant impact of systematic errors, particularly IAs. We provide forecasts for the expected signal-to-noise of the combination of the five-year DES survey and SPT-3G.

  16. Evaluation of antioxidants and argpyrimidine in normal and cataractous lenses in north Indian population

    Directory of Open Access Journals (Sweden)

    Bharani K Mynampati

    2017-07-01

    Full Text Available AIM: To assess the level of glutathione, thioltransferase, and argpyrimidine in nuclear and cortical cataractous lenses as well as in the clear lenses in the north Indian population. METHODS: Human cataractous lenses were collected from the patients who underwent extracapsular cataract extraction surgery; clear lenses were collected from the freshly donated eye bank eyes. Antioxidant molecules such as glutathione and thioltransferase enzyme activity were measured; simultaneously in these lenses a blue fluorophore argpyrimidine, an advanced glycation end (AGE product level was assessed using high performance liquid chromatography (HPLC. RESULTS: The protein concentration was found to be present at higher levels in the control lenses compared to cataract lenses. A significant decrease in the glutathione level was observed in the nuclear cataractous lenses compared to cortical cataractous (P=0.004 and clear lenses (P≤0.005, but no significant change in the level of antioxidant enzyme thioltransferase was observed. Further, argpyrimidine a blue fluorophore (AGE was found to be significantly higher in the nuclear cataract (P=0.013 compared to cortical cataract lenses. CONCLUSION: Antioxidants such as glutathione significantly decrease in age-related nuclear and cortical cataract and an AGE, argpyrimidine are present at significantly higher levels in nuclear cataract.

  17. Comparative Evaluation of Ultraviolet and Visible Light Transmittance through Prescriptive Ophthalmic Minus Lenses

    Directory of Open Access Journals (Sweden)

    Mohammadreza Nazari

    2014-06-01

    Full Text Available Background: Wearing spectacles is the most common approach in correcting the refractive errors worldwide. Due to harmful effects of overexposure to solar ultraviolet radiations, the usage of multi-layer coatings in ophthalmic lenses has recently been increased. These lenses can reduce the reflections and hence increase the transmission of visible light; they can also decrease the transmission of ultraviolet rays. This study aims to compare the transmission of ultraviolet (A and B and visible rays through coated and uncoated prescriptive ophthalmic plastic lenses.Materials and Methods: In this study, 39 minus non-photochromic multi-coated white plastic single-vision lenses; 9 similar lenses but without any coatings were assessed by spectral transmittancemeter for evaluation of the transmission of visible and ultraviolet rays.Results: The transmission of visible light was 97.9%±1.07% for coated lenses and 93.5%±0.54% for lenses without coating. Ultraviolet-A transmission was 12.15%±8.02% for coated lenses compared to 66.27%±23.92% in lenses without coating. The transmission of ultraviolet-B rays was 1.21%±0.4% and 23.0%±15.97% for lenses with and without coatings, respectively.Conclusion: The transmission of visible light was significantly higher in multi-coated lenses compared to uncoated samples; whereas the transmissions of ultraviolet rays in multi-coated lenses were significantly lower than uncoated ones. Therefore, it is recommended that, except for particular cases, prescribed lenses be equipped with this multi-layer coating.

  18. CMB Beam Systematics: Impact on Lensing Parameter Estimation

    OpenAIRE

    Miller, N. J.; Shimon, M.; Keating, B. G.

    2008-01-01

    The CMB's B-mode polarization provides a handle on several cosmological parameters most notably the tensor-to-scalar ratio, $r$, and is sensitive to parameters which govern the growth of large scale structure (LSS) and evolution of the gravitational potential. The primordial gravitational-wave- and secondary lensing-induced B-mode signals are very weak and therefore prone to various foregrounds and systematics. In this work we use Fisher-matrix-based estimations and apply, for the first time,...

  19. Strategies to regulate myopia progression with contact lenses: a review

    OpenAIRE

    González-Méijome, José Manuel; Matos, Sofia Cláudia Peixoto; Ribeiro, Miguel António Faria; Ferreira, Daniela Patrícia Lopes; Jorge, Jorge; Legerton, Jerry; Queirós, A.

    2016-01-01

    Purpose: Higher myopic refractive errors are associated with serious ocular complications that can put visual function at risk. There is respective interest in slowing and if possible stopping myopia progression before it reaches a level associated with increased risk of secondary pathology. The purpose of this report was to review our understanding of the rationale(s) and success of contact lenses (CLs) used to reduce myopia progression. Methods: A review commenced by searc...

  20. 3D weak lensing with spin wavelets on the ball

    Science.gov (United States)

    Leistedt, Boris; McEwen, Jason D.; Kitching, Thomas D.; Peiris, Hiranya V.

    2015-12-01

    We construct the spin flaglet transform, a wavelet transform to analyze spin signals in three dimensions. Spin flaglets can probe signal content localized simultaneously in space and frequency and, moreover, are separable so that their angular and radial properties can be controlled independently. They are particularly suited to analyzing cosmological observations such as the weak gravitational lensing of galaxies. Such observations have a unique 3D geometrical setting since they are natively made on the sky, have spin angular symmetries, and are extended in the radial direction by additional distance or redshift information. Flaglets are constructed in the harmonic space defined by the Fourier-Laguerre transform, previously defined for scalar functions and extended here to signals with spin symmetries. Thanks to various sampling theorems, both the Fourier-Laguerre and flaglet transforms are theoretically exact when applied to bandlimited signals. In other words, in numerical computations the only loss of information is due to the finite representation of floating point numbers. We develop a 3D framework relating the weak lensing power spectrum to covariances of flaglet coefficients. We suggest that the resulting novel flaglet weak lensing estimator offers a powerful alternative to common 2D and 3D approaches to accurately capture cosmological information. While standard weak lensing analyses focus on either real- or harmonic-space representations (i.e., correlation functions or Fourier-Bessel power spectra, respectively), a wavelet approach inherits the advantages of both techniques, where both complicated sky coverage and uncertainties associated with the physical modeling of small scales can be handled effectively. Our codes to compute the Fourier-Laguerre and flaglet transforms are made publicly available.

  1. Moment aberrations in magneto-electrostatic plasma lenses (computer simulation)

    CERN Document Server

    Butenko, V I

    2001-01-01

    In this work moment aberrations in the plasma magneto-electrostatic lenses are considered in more detail with the use of the computer modeling. For solution of the problem we have developed a special computer code - the model of plasma optical focusing device, allowing to display the main parameters and operations of experimental sample of a lens, to simulate the moment and geometrical aberrations and give recommendations on their elimination.

  2. Combining Galaxy-Galaxy Lensing and Galaxy Clustering

    Energy Technology Data Exchange (ETDEWEB)

    Park, Youngsoo [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Krause, Elisabeth [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Dodelson, Scott [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Jain, Bhuvnesh [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Amara, Adam [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Becker, Matt [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Bridle, Sarah [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Clampitt, Joseph [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Crocce, Martin [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Honscheid, Klaus [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Gaztanaga, Enrique [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Sanchez, Carles [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Wechsler, Risa [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2015-01-01

    Combining galaxy-galaxy lensing and galaxy clustering is a promising method for inferring the growth rate of large scale structure, a quantity that will shed light on the mechanism driving the acceleration of the Universe. The Dark Energy Survey (DES) is a prime candidate for such an analysis, with its measurements of both the distribution of galaxies on the sky and the tangential shears of background galaxies induced by these foreground lenses. By constructing an end-to-end analysis that combines large-scale galaxy clustering and small-scale galaxy-galaxy lensing, we also forecast the potential of a combined probes analysis on DES datasets. In particular, we develop a practical approach to a DES combined probes analysis by jointly modeling the assumptions and systematics affecting the different components of the data vector, employing a shared halo model, HOD parametrization, photometric redshift errors, and shear measurement errors. Furthermore, we study the effect of external priors on different subsets of these parameters. We conclude that DES data will provide powerful constraints on the evolution of structure growth in the universe, conservatively/ optimistically constraining the growth function to 8%/4.9% with its first-year data covering 1000 square degrees, and to 4%/2.3% with its full five-year data covering 5000 square degrees.

  3. Precise LIGO lensing rate predictions for binary black holes

    Science.gov (United States)

    Ng, Ken K. Y.; Wong, Kaze W. K.; Broadhurst, Tom; Li, Tjonnie G. F.

    2018-01-01

    We show how LIGO is expected to detect coalescing binary black holes at z >1 that are lensed by the intervening galaxy population. Gravitational magnification, μ , strengthens gravitational-wave signals by √{μ } without altering their frequencies, which if unrecognized leads to an underestimate of the event redshift and hence an overestimate of the binary mass. High magnifications can be reached for coalescing binaries, because the region of intense gravitational-wave emission during coalescence is so small (˜100 km ), permitting very close projections between lensing caustics and gravitational-wave events. Our simulations use the current LIGO event-based mass function and incorporate accurate waveforms convolved with the LIGO power spectral density. Importantly, we include the detection dependence on sky position and orbital orientation, which for the LIGO configuration translates into a wide spread in observed redshifts and chirp masses. Currently, we estimate a detectable rate of lensed events 0. 06-0.02+0.02 yr-1 that rises to 5-3+5 yr-1 at LIGO design sensitivity limit, depending on the high redshift rate of black hole coalescence.

  4. FISHEYE LENSES FOR 3D MODELING: EVALUATIONS AND CONSIDERATIONS

    Directory of Open Access Journals (Sweden)

    L. Barazzetti

    2017-02-01

    Full Text Available Fisheye lenses are becoming more popular in complete image-based modelling projects of small and narrow spaces. The growing interest in fisheye lenses is confirmed by the availability of different commercial software incorporating a fisheye camera model. Such software are now able to carry out the steps of the image processing pipeline in a fully automated way, from camera calibration and orientation to dense matching, surface generation, and orthophoto production. This paper highlights the advantages (and disadvantages of fisheye lenses when used for 3D modelling projects through different commercial software. The goal is not only a comparison of commercial software, but also an analysis of the additional issues that arise when a fisheye lens is used for 3D modelling. Results confirm that a fisheye lens is suitable for accurate metric documentation, especially when limited space is available. On the other hand, additional issues where found during the camera calibration/image orientation step as well as the texture generation and orthophoto production phases, for which particular attention is required.

  5. Electrically controllable ionic polymeric gels as adaptive optical lenses

    Science.gov (United States)

    Salehpoor, Karim; Shahinpoor, Mohsen; Mojarrad, Mehran

    1996-02-01

    Reversible change in optical properties of ionic polymeric gels, 2-acrylamido-2-methylpropane sulfonic acid (PAMPS) and polyacrylic acid plus sodium acrylate cross-linked with bisacrylamide (PAAM), under the effect of an electric field is reported. The shape of a cylindrical piece of the gel, with flat top and bottom surfaces, changed when affected by an electric field. The top surface became curved and the sense of the curvature (whether concave or convex) depended on the polarity of the applied electric field. The curvature of the surface changed from concave to convex and vice versa by changing the polarity of the electric field. By the use of an optical apparatus, focusing capability of the curved surface was verified and the focal length of the deformed gel was measured. The effect of the intensity of the applied electric field on the surface curvature and thus, on the focal length of the gel are tested. Different mechanisms are discussed; either of them or their combination may explain the surface deformation and curvature. Practical difficulties in the test procedure and the future potential of the electrically adaptive and active optical lenses are also discussed. These adaptive lenses may be considered as smart adaptive lenses for contact lens or other optical applications requiring focal point undulation.

  6. Acanthamoeba keratitis in patients wearing scleral contact lenses.

    Science.gov (United States)

    Sticca, Matheus Porto; Carrijo-Carvalho, Linda C; Silva, Isa M B; Vieira, Luiz A; Souza, Luciene B; Junior, Rubens Belfort; Carvalho, Fábio Ramos S; Freitas, Denise

    2017-12-05

    To report a series of cases of Acanthamoeba keratitis (AK) in scleral lens wearers with keratoconus to determine whether this type of contact lens presents a greater risk for development of infection. This study reports three patients who wore scleral contact lenses to correct keratoconus and developed AK. The diagnoses of AK were established based on cultures of the cornea, scleral contact lenses, and contact lens paraphernalia. This study investigated the risk factors for infections. The possible risks for AK in scleral contact lens wearers are hypoxic changes in the corneal epithelium because of the large diameter and minimal tear exchange, use of large amounts of saline solution necessary for scleral lens fitting, storing the scleral lens overnight in saline solution rather than contact lens multipurpose solutions, not rubbing the contact lens during cleaning, and the space between the cornea and the back surface of the scleral lens that might serve as a fluid reservoir and environment for Acanthamoeba multiplication. Two patients responded well to medical treatment of AK; one is still being treated. The recommendations for use and care of scleral contact lenses should be emphasized, especially regarding use of sterile saline (preferably single use), attention to rubbing the lens during cleaning, cleaning of the plunger, and overnight storage in fresh contact lens multipurpose solutions without topping off the lens solution in the case. Copyright © 2017. Published by Elsevier Ltd.

  7. Investigating the shelf life of disposable soft contact lenses

    Directory of Open Access Journals (Sweden)

    E. Chetty

    2008-12-01

    Full Text Available Numerous studies have been done to scrutinize the sterility and/or efficacy of contact lens solutions1-3, contact lens storage cases4-6 and soft contact lenses (SCLs 7-10. To the best of our knowledge, a paucity of research regarding the sterility or efficacy of expired SCLs that are in sealed packages exists. One may question the need to investigate this facet of contact lens research. Many blogs and Q&A websites, such as the Optiboard website11, feature contact lens practitioners or contact lens patients who are curious about the repercussions of using expired SCLs. The purpose of this pilot study is not to offer all the answers regarding expired contact lenses, but rather to initiate curiosity about the quality and utility of expired SCLs. This study endeavors to investigate the sterility of sealed SCLs that are past their expiry date. Fifty-four SCLs were tested for the presence of fungal (27 samples and bacterial (27 samples contamination. These samples included both expired and unexpired SCLs that were either blister packed or vial packed. A small percentage of the lenses testedpositive for contamination.

  8. THE THIRD GRAVITATIONAL LENSING ACCURACY TESTING (GREAT3) CHALLENGE HANDBOOK

    International Nuclear Information System (INIS)

    Mandelbaum, Rachel; Kannawadi, Arun; Simet, Melanie; Rowe, Barnaby; Kacprzak, Tomasz; Bosch, James; Miyatake, Hironao; Chang, Chihway; Gill, Mandeep; Courbin, Frederic; Jarvis, Mike; Armstrong, Bob; Lackner, Claire; Leauthaud, Alexie; Nakajima, Reiko; Rhodes, Jason; Zuntz, Joe; Bridle, Sarah; Coupon, Jean; Dietrich, Jörg P.

    2014-01-01

    The GRavitational lEnsing Accuracy Testing 3 (GREAT3) challenge is the third in a series of image analysis challenges, with a goal of testing and facilitating the development of methods for analyzing astronomical images that will be used to measure weak gravitational lensing. This measurement requires extremely precise estimation of very small galaxy shape distortions, in the presence of far larger intrinsic galaxy shapes and distortions due to the blurring kernel caused by the atmosphere, telescope optics, and instrumental effects. The GREAT3 challenge is posed to the astronomy, machine learning, and statistics communities, and includes tests of three specific effects that are of immediate relevance to upcoming weak lensing surveys, two of which have never been tested in a community challenge before. These effects include many novel aspects including realistically complex galaxy models based on high-resolution imaging from space; a spatially varying, physically motivated blurring kernel; and a combination of multiple different exposures. To facilitate entry by people new to the field, and for use as a diagnostic tool, the simulation software for the challenge is publicly available, though the exact parameters used for the challenge are blinded. Sample scripts to analyze the challenge data using existing methods will also be provided. See http://great3challenge.info and http://great3.projects.phys.ucl.ac.uk/leaderboard/ for more information

  9. An experimental study of nanoparticle focusing with aerodynamic lenses

    Science.gov (United States)

    Wang, Xiaoliang; McMurry, Peter H.

    2006-12-01

    High sampling efficiencies of analyte ions, molecules or particles are needed to maximize the sensitivity of mass spectrometers. "Ion funnels", which utilize electrodynamic focusing, have been shown to effectively focus ions with mass-to-charge ratio (m/z) ranging from ~100 to 5000. Focusing efficiencies of ion funnels drop for higher m/z values because very high voltages are needed to overcome the particle inertia. Conventional "aerodynamic lenses" utilize inertia to focus down to 25 nm in diameter (~5 MDa); to date, Brownian diffusion has prevented the effective focusing of particles smaller than this. We recently reported a design procedure that should, in principle, extend focusing with aerodynamic lenses to particles as small as 3 nm (~10 kDa), thereby bridging the gap between the ion funnel and the conventional aerodynamic lenses. In this paper, we report for the first time experimental results for the performance of these new "nanolenses". Measurements were done using spherical oil droplets, proteins, and sodium chloride particles ranging in size from 3 to 30 nm diameter. We found that particle transport efficiencies from atmospheric pressure to vacuum through the aerodynamic lens system were greater than 80% for 10-30 nm particles, and greater than 50% for a ~3.8 nm protein (Lysozyme from chicken egg white, molecular weight 14.3 kDa). Particle beam diameters were about a factor of two greater than predicted by our numerical simulations, but provide clear evidence that the nanolenses effectively focus all three particle types.

  10. Applications of Electronstatic Lenses to Electron Gun and Energy Analyzers

    International Nuclear Information System (INIS)

    Sise, O.

    2004-01-01

    Focal properties and geometries are given for several types of electrostatic lens systems commonly needed in electron impact studies. One type is an electron gun which focuses electrons over a wide range of energy onto a fixed point, such as target, and the other type is an analyzer system which focuses scattered electrons of variable energy onto a fixed position, such as the entrance plane of an analyzer. There are many different types and geometries of these lenses for controlling and focusing of the electron beams. In this presentation we discussed the criteria used for the design of the electrostatic lenses associated with the electron gun and energy analyzers and determined the fundamental relationships between the operation and behaviour of multi-element electrostatic lenses, containing five, six and seven elements. The focusing of the electron beam was achieved by applying suitable voltages to the series of these lens elements, Design of the lens system for electron gun was based on our requirements that the beam at the target had a small spot size and zero beam angle, that is, afocal mode. For energy analyzer systems we considered the entrance of the hemispherical analyzer which determines the energy of the electron beam and discussed the focusing condition of this lens systems

  11. Meso-Structure in Three Strong-lensing Systems

    Science.gov (United States)

    Saha, Prasenjit; Williams, Liliya L. R.; Ferreras, Ignacio

    2007-07-01

    We map substructure in three strong-lensing systems having particularly good image data: the galaxy lens MG J0414+053 and the clusters SDSS J1004+411 and ACO 1689. Our method is to first reconstruct the lens as a pixelated mass map and then subtract off the symmetric part (in the galaxy case) or a projected Navarro-Frenk-White profile (for the cluster lenses). In all three systems we find extended irregular structures, or meso-structures, having of order 10% of the total mass. In J0414+053, the meso-structure suggests a tidal tail connecting the main lens with a nearby galaxy; however, this interpretation is tentative. In the clusters, the identification of meso-structure is more secure, especially in ACO 1689, where two independent sets of lensed images imply very similar meso-structure. In all three cases, the meso-structures are correlated with galaxies but much more extended and massive than the stellar components of single galaxies. Such extended structures cannot plausibly persist in such high-density regions without being mixed; the crossing times are too short. The meso-structures therefore appear to be merging or otherwise dynamically evolving systems.

  12. Origami with negative refractive index to generate super-lenses

    International Nuclear Information System (INIS)

    Guenneau, Fanny; Chakrabarti, Sangeeta; Guenneau, Sebastien; Ramakrishna, S Anantha

    2014-01-01

    Negative refractive index materials (NRIM) enable unique effects including superlenses with a high degree of sub-wavelength image resolution, a capability that stems from the ability of NRIM to support a host of surface plasmon states. Using a generalized lens theorem and the powerful tools of transformational optics, a variety of focusing configurations involving complementary positive and negative refractive index media can be generated. A paradigm of such complementary media are checkerboards that consist of alternating cells of positive and negative refractive index, and are associated with very singular electromagnetics. We present here a variety of multi-scale checkerboard lenses that we call origami lenses and investigate their electromagnetic properties both theoretically and computationally. Some of these meta-structures in the plane display thin bridges of complementary media, and this highly enhances their plasmonic response. We demonstrate the design of three-dimensional checkerboard meta-structures of complementary media using transformational optics to map the checkerboard onto three-dimensional corner lenses, the only restriction being that the corresponding unfolded structures in the plane are constrained by the four color-map theorem. (paper)

  13. Seawater intrusion vulnerability indicators for freshwater lenses in strip islands

    Science.gov (United States)

    Morgan, L.; Werner, A. D.

    2014-12-01

    Freshwater lenses on small islands have been described as some of the most vulnerable aquifer systems in the world. Yet, little guidance is available regarding methods for rapidly assessing the vulnerability of freshwater lenses to the potential effects of climate change. To address this gap we employ a steady-state analytic modelling approach to develop seawater intrusion (SWI) vulnerability indicator equations. The vulnerability indicator equations quantify the propensity for SWI to occur in strip islands due to both recharge change and sea-level rise (SLR) (incorporating the effect of land surface inundation (LSI)). This work extends that of Werner et al. (2012) who developed SWI vulnerability indicator equations for unconfined and confined continental aquifers, and did not consider LSI. Flux-controlled and head-controlled conceptualisations of freshwater lenses are adopted. Under flux-controlled conditions the water table is able to rise unencumbered by land surface effects. Under head-controlled conditions the head is fixed at the centre of the lens due to, for example, centrally located topographic controls, surface water features or pumping. A number of inferences about SWI vulnerability in freshwater lenses can be made from the analysis: (1) SWI vulnerability indicators for SLR (under flux-controlled conditions) are proportional to lens thickness (or volume) and the rate of LSI and inversely proportional to island width; (2) SWI vulnerability indicators for recharge change (under flux-controlled conditions) are proportional to lens thickness (or volume) and inversely proportional to recharge; (3) SLR has greater impact under head-controlled conditions rather than flux-controlled conditions, whereas the opposite is the case for LSI and recharge change. Example applications to several case studies illustrate use of the method for rapidly ranking lenses according to vulnerability, thereby allowing for prioritisation of areas where further and more detailed SWI

  14. Strong lensing by fermionic dark matter in galaxies

    Science.gov (United States)

    Gómez, L. Gabriel; Argüelles, C. R.; Perlick, Volker; Rueda, J. A.; Ruffini, R.

    2016-12-01

    It has been shown that a self-gravitating system of massive keV fermions in thermodynamic equilibrium correctly describes the dark matter (DM) distribution in galactic halos (from dwarf to spiral and elliptical galaxies) and that, at the same time, it predicts a denser quantum core towards the center of the configuration. Such a quantum core, for a fermion mass in the range of 50 keV ≲m c2≲345 keV , can be an alternative interpretation of the central compact object in Sgr A*, traditionally assumed to be a black hole (BH). We present in this work the gravitational lensing properties of this novel DM configuration in nearby Milky-Way-like spiral galaxies. We describe the lensing effects of the pure DM component both on halo scales, where we compare them to the effects of the Navarro-Frenk-White and the nonsingular isothermal sphere DM models, and near the galaxy center, where we compare them with the effects of a Schwarzschild BH. For the particle mass leading to the most compact DM core, m c2≈1 02 keV , we draw the following conclusions. At distances r ≳20 pc from the center of the lens the effect of the central object on the lensing properties is negligible. However, we show that measurements of the deflection angle produced by the DM distribution in the outer region at a few kpc, together with rotation curve data, could help to discriminate between different DM models. In the inner regions 1 0-6≲r ≲20 pc , the lensing effects of a DM quantum core alternative to the BH scenario becomes a theme of an analysis of unprecedented precision which is challenging for current technological developments. We show that at distances ˜1 0-4 pc strong lensing effects, such as multiple images and Einstein rings, may occur. Large differences in the deflection angle produced by a DM central core and a central BH appear at distances r ≲1 0-6 pc ; in this regime the weak-field formalism is no longer applicable and the exact general-relativistic formula has to be used

  15. Data transfer through beam steering using agile lensing

    Science.gov (United States)

    Arshad, Muhammad Assad; Reza, Syed Azer; Muhammad, Ahsan

    2016-04-01

    This paper presents a data transfer scheme using multi-focus tunable lenses. The design involves the use of a standard laser source and a variable focus agile lens to steer to the laser beam that passes through the lens. In our proposed system, the beam steer angle depends on an input electrical signal which drives the tunable lens. Therefore the beam steer angle is made to follow the variations in the input electrical drive signal. This is extremely interesting for data transfer applications as the data signal can be used as the input drive signal to the lens. The laser beam is steered according to the input data voltage levels and when the beam is incident on a photo-detector of a finite size, only a fraction of its total incident optical power is received by the photo-detector. This power contribution is proportional to the fraction of the total number of photons per unit area which are incident on the active area of the detector. The remaining photons which are not incident on the photo-detector do not contribute to the received power at the photo-detector. We present the theory of beam steering through a tunable lens and present a theoretical framework which governs data transfer through the proposed method. We also present the transfer function of the proposed system which helps us to calculate its essential theoretical performance parameters such as modulation depth and bit error rates. We also present experimental results to demonstrate efficient data transfer through the proposed method. As tunable lenses are primarily deployed in motion-free multi-focus cameras hence most of the modern portable devices such as cellphones and tablets use these lenses to operate the in-built variable focus cameras that are part of these devices. Because tunable lenses are commonly present in several different portable devices, the proposed method of data transfer between two devices is highly promising as it expands the use of the already deployed tunable lenses with

  16. Static Linear Fresnel Lenses as LCPV System in a Greenhouse

    Science.gov (United States)

    Sonneveld, P. J.; Swinkels, G. L. A. M.; van Tuijl, B. A. J.; Janssen, H. J. J.; de Zwart, H. F.

    2011-12-01

    A low concentrating PV system with water cooling (LCPVT system) will result in electrical and thermal energy output from the solar energy excess entering a building or greenhouse. All the direct radiation could be converted, which corresponds to 75% of the incoming solar energy. This will significantly reduce the demand of cooling of the building. For an optimal performance it is beneficial to construct asymmetric roof elements with a steep inclination at the north side (the exact angle of course depends on the latitude of the building site). The Fresnel lens structure is oriented in upwards direction. In the current design, two of them are placed between an AR-coated double glass structure to prevent pollution and condensation on the lenses. Compared with a previous system, the number of lenses is reduced from 3 to 2 lenses, which reduces the costs of the system by limiting the number of receivers. By the upward facing of the lens structure, the focus quality is preserved over a much broader range of angles of incidence compared to a lens with downward facing structures. Each PMMA lens with a size of 1.20 m×1.60 m is composed of 12 `tiles' for easy production. The focal distance of the lens is 1,875 m and the concentration factor 50x. In most cases the focus line is thinner than 3 cm and the transmission is above 80%. The performance of these lenses with respect of the shape of the focal area and the position of the focal line has been analyzed with ray tracing techniques. From this analyses it was concluded that tracking of the receiver module is possible with two motors. One motor controls the distance between lens and receiver and one motor controls the translocation of the receivers parallel to the lens. The second conclusion was that the positions of the focal line are within the bounds of the greenhouse construction for almost the whole year. Only in winter, the focal line will be unreachable from time to time. A 480 m2 greenhouse with the LCPVT system

  17. Lense-Thirring precession around neutron stars with known spin

    Science.gov (United States)

    Van Doesburgh, Marieke; van der Klis, Michiel

    2016-07-01

    Quasi periodic oscillations (QPOs) between 300 and 1200 Hz in the X-ray emission from low mass X-ray binaries have been linked to Keplerian orbital motion at the inner edge of accretion disks. Lense-Thirring precession is precession of the line of nodes of inclined orbits with respect to the equatorial plane of a rotating object due to the general relativistic effect of frame dragging. The Lense-Thirring model of Stella and Vietri (1998) explains QPOs observed in neutron star low mass X-ray binaries at frequencies of a few tens of Hz by the nodal precession of the orbits at the inner disk edge at a precession frequency, ν_{LT} , identical to the Lense-Thirring precession of a test particle orbit. A quadratic relation between ν_{LT} and the Keplerian orbital frequency, and a linear dependence on spin frequency are predicted. In early work (van Straaten et al., 2003) this quadratic relation was confirmed to remarkable precision in three objects of uncertain spin. Since the initial work, many neutron star spin frequencies have been measured in X-ray sources that show QPOs at both low and high frequency. Using archival data from the Rossi X-ray Timing Explorer, we compare the Lense-Thirring prediction to the properties of quasi periodic oscillations measured in a sample of 14 low mass X-ray binaries of which the neutron star spin frequencies can be inferred from their bursting behaviour. We find that in the range predicted for the precession frequency, we can distinguish two different oscillations that often occur simultaneously. In previous works, these two oscillations have often been confused. For both frequencies, we find correlations with inferred Keplerian frequency characterized by power laws with indices that differ significantly from the prediction of 2.0 and therefore inconsistent with the Lense-Thirring model. Also, the specific moment of inertia of the neutron star required by the observed frequencies exceeds values predicted for realistic equations of

  18. Seeing (and Doing) Conservation Through Cultural Lenses

    Science.gov (United States)

    Peterson, Richard B.; Russell, Diane; West, Paige; Brosius, J. Peter

    2010-01-01

    In this paper, we first discuss various vantage points gained through the authors’ experience of approaching conservation through a “cultural lens.” We then draw out more general concerns that many anthropologists hold with respect to conservation, summarizing and commenting on the work of the Conservation and Community Working Group within the Anthropology and Environment Section of the American Anthropological Association. Here we focus on both critiques and contributions the discipline of anthropology makes with regard to conservation, and show how anthropologists are moving beyond conservation critiques to engage actively with conservation practice and policy. We conclude with reflections on the possibilities for enhancing transdisciplinary dialogue and practice through reflexive questioning, the adoption of disciplinary humility, and the realization that “cross-border” collaboration among conservation scholars and practitioners can strengthen the political will necessary to stem the growing commoditization and ensuing degradation of the earth’s ecosystems.

  19. Get Milk – A Game of Lenses

    DEFF Research Database (Denmark)

    Ghellal, Sabiha; Holopainen, Jussi; Schneider, Tobias

    2015-01-01

    Even though teaching game design has been discussed in numerous scientific and commercial publications there has been surprisingly little work discussing the merits and drawbacks of interactive learning tools that make game design theory an experience as part of an educational strategy. A common...... challenge while teaching game design is to help students to regard games with the perspective of a game designer and not as a gamer during the design process. For students the challenge lies in understanding the purpose and merits of game design theory and how it may help designing better games, in other...... words, how to apply the theory successfully in practice. In order to enable students to start looking at games from the perspective of a game designer with the purpose of discussing the suitability of applied game design mechanics (Hunicke et al., 2004) or patterns (Björk & Holopainen, 2004) we designed...

  20. Surface interactions on hydrogel extended wear contact lenses: microflora and microfauna.

    Science.gov (United States)

    Hart, D E; Shih, K L

    1987-10-01

    The microbial flora and fauna of 25 high water content nonionic "soft" contact lenses worn by patients on an extended wear basis, 4 hand-cleaned patient-worn lenses, and 4 improperly maintained lenses were compared. Almost all the patient-worn lenses (24 of 25) were free of viable microorganisms, whereas all the hand-cleaned lenses (4 of 4) were contaminated with different microorganisms. This study showed that hand contact is a major source of microbial contamination of a lens and that usually the hand-transported microorganisms do not survive permanently on the lens in a healthy, normal eye. Improperly maintained lenses demonstrated pathogenic microbial associations. Proof of the eye's potent antimicrobial environment was demonstrated. Thus, microorganism-lens associations are largely due to lens handling and inappropriate maintenance regimens. Typically there are few microorganisms on an extended wear soft lens while it is being worn.

  1. A novel method of fitting scleral lenses using high resolution optical coherence tomography.

    Science.gov (United States)

    Gemoules, Greg

    2008-03-01

    Case report study of a novel method of fitting large rigid gas-permeable lenses (cornea-scleral, mini-scleral, scleral). Nine patients with different corneal and refractive conditions were fitted with scleral-type rigid gas-permeable lenses using high resolution ocular coherence tomography. All patients achieved excellent visual acuity and comfort. Lenses were well tolerated without significant complications. Three cases are discussed in detail. Two of the 3 patients had previously undergone fitting with trial lenses so that the different methods could be compared with respect to number of lenses used to achieve a final fit. High resolution biometry proved to be a highly useful fitting tool and seems to offer a more accurate and efficient alternative to fitting scleral-type lenses compared with the trial lens method.

  2. Efficacy of progressive addition lenses in the treatment of ametropia after the single eye's IOL implantation.

    Science.gov (United States)

    Chen, Lin Xing; Zeng, Ying Yu; Zeng, Jun Wen; He, Ming Guang

    2012-09-01

    To investigate the efficacy of progressive addition lenses on the treatment of ametropia and loss of accomodation after the single eye's IOL implantation. Eighty four patients undergoing IOL implantation in single eyes were prescribed with progressive addition lenses for ametropia correction and regularly followed up to observe subsequent correction effect. Among these 84 patients, 72 could comfortably adapt to the use of progressive addition lenses to improve visual acuity and accomondation, while the remaining 12 patients failed to accomodate the usage of progressive addition lenses. Wearing progressive addition lenses acts as a relatively feasible approach to improve visual acuity and alleviate disorders of accomodation for patients who underwent IOL implantation in single eyes. The patients should be prescribed with progressive lenses under professional instructions and guidance.

  3. Interpreting the Strongly Lensed Supernova iPTF16geu: Time Delay Predictions, Microlensing, and Lensing Rates

    Energy Technology Data Exchange (ETDEWEB)

    More, Anupreeta; Oguri, Masamune; More, Surhud [Kavli Institute for the Physics and Mathematics of the Universe (Kavli IPMU, WPI), University of Tokyo, Chiba 277-8583 (Japan); Suyu, Sherry H. [Max-Planck-Institut für Astrophysik, Karl-Schwarzschild-Str. 1, D-85748 Garching (Germany); Lee, Chien-Hsiu, E-mail: anupreeta.more@ipmu.jp [Subaru Telescope, National Astronomical Observatory of Japan, 650 North Aohoku Place, Hilo, HI 96720 (United States)

    2017-02-01

    We present predictions for time delays between multiple images of the gravitationally lensed supernova, iPTF16geu, which was recently discovered from the intermediate Palomar Transient Factory (iPTF). As the supernova is of Type Ia where the intrinsic luminosity is usually well known, accurately measured time delays of the multiple images could provide tight constraints on the Hubble constant. According to our lens mass models constrained by the Hubble Space Telescope F814W image, we expect the maximum relative time delay to be less than a day, which is consistent with the maximum of 100 hr reported by Goobar et al. but places a stringent upper limit. Furthermore, the fluxes of most of the supernova images depart from expected values suggesting that they are affected by microlensing. The microlensing timescales are small enough that they may pose significant problems to measure the time delays reliably. Our lensing rate calculation indicates that the occurrence of a lensed SN in iPTF is likely. However, the observed total magnification of iPTF16geu is larger than expected, given its redshift. This may be a further indication of ongoing microlensing in this system.

  4. Bayesian galaxy shape measurement for weak lensing surveys - III. Application to the Canada-France-Hawaii Telescope Lensing Survey

    Science.gov (United States)

    Miller, L.; Heymans, C.; Kitching, T. D.; van Waerbeke, L.; Erben, T.; Hildebrandt, H.; Hoekstra, H.; Mellier, Y.; Rowe, B. T. P.; Coupon, J.; Dietrich, J. P.; Fu, L.; Harnois-Déraps, J.; Hudson, M. J.; Kilbinger, M.; Kuijken, K.; Schrabback, T.; Semboloni, E.; Vafaei, S.; Velander, M.

    2013-03-01

    A likelihood-based method for measuring weak gravitational lensing shear in deep galaxy surveys is described and applied to the Canada-France-Hawaii Telescope (CFHT) Lensing Survey (CFHTLenS). CFHTLenS comprises 154 deg2 of multi-colour optical data from the CFHT Legacy Survey, with lensing measurements being made in the i' band to a depth i'AB noise ratio νSN ≳ 10. The method is based on the lensfit algorithm described in earlier papers, but here we describe a full analysis pipeline that takes into account the properties of real surveys. The method creates pixel-based models of the varying point spread function (PSF) in individual image exposures. It fits PSF-convolved two-component (disc plus bulge) models to measure the ellipticity of each galaxy, with Bayesian marginalization over model nuisance parameters of galaxy position, size, brightness and bulge fraction. The method allows optimal joint measurement of multiple, dithered image exposures, taking into account imaging distortion and the alignment of the multiple measurements. We discuss the effects of noise bias on the likelihood distribution of galaxy ellipticity. Two sets of image simulations that mirror the observed properties of CFHTLenS have been created to establish the method's accuracy and to derive an empirical correction for the effects of noise bias.

  5. Ability of silver-impregnated contact lenses to control microbial growth and colonisation

    OpenAIRE

    Mark D.P. Willcox; Emma B.H. Hume; Ajay K. Vijay; Robert Petcavich

    2010-01-01

    Purpose: To examine the ability of silver nano-particles to prevent the growth of Pseudomonas aeruginosa and Staphylococcus aureus in solution or when adsorbed into contact lenses. To examine the ability of silver nano-particles to prevent the growth of Acanthamoeba castellanii. Methods: Etafilcon A lenses were soaked in various concentrations of silver nano-particles. Bacterial cells were then exposed to these lenses, and numbers of viable cells on lens surface or in solution compared to ...

  6. Mapping the distribution of luminous and dark matter in strong lensing galaxies

    OpenAIRE

    Ferreras, I.; Saha, P.; Williams, L. L. R.; Burles, S.

    2007-01-01

    We present the distribution of luminous and dark matter in a set of strong lensing (early-type) galaxies. By combining two independent techniques – stellar population synthesis and gravitational lensing – we can compare the baryonic and dark matter content in these galaxies within the regions that can be probed using the images of the lensed background source. Two samples were studied, extracted from the CASTLES and SLACS surveys. The former probes a wider range of redshifts and allows us to ...

  7. Plans for Deployment of Hollow Electron Lenses at the LHC for Enhanced Beam Collimation

    Energy Technology Data Exchange (ETDEWEB)

    Redaelli, S. [CERN; Bertarelli, A. [CERN; Bruce, R. [CERN; Perini, D. [CERN; Rossi, A. [CERN; Salvachua, B. [CERN; Stancari, G. [Fermilab; Valishev, A. [Fermilab

    2015-06-01

    Hollow electron lenses are considered as a possible means to improve the LHC beam collimation system, providing active control of halo diffusion rates and suppressing the population of transverse halos. After a very successful experience at the Tevatron, a conceptual design of a hollow e-lens optimized for the LHC was produced. Recent further studies have led to a mature preliminary technical design. In this paper, possible scenarios for the deployment of this technology at the LHC are elaborated in the context of the scheduled LHC long shutdowns until the full implementation of the HL-LHC upgrade in 2023. Possible setups of electron beam test stands at CERN and synergies with other relevant electron beam programmes are also discussed.

  8. The SISSI project: An intense secondary ion source using superconducting solenoid lenses

    International Nuclear Information System (INIS)

    Joubert, A.; Baron, E.; Grunberg, C.; Mittig, W.; Ripouteau, F.; Larson, J.D.

    1991-01-01

    Secondary beams are routinely produced at GANIL for experiments from a target placed in the high energy beam line of the accelerator. In order to make a better use of the higher beam intensities soon available at GANIL, a proposal called 'SISSI' was presented in 1989. This project is now funded. It consists of a set of two superconducting solenoid lenses of very short focal length (.6m). The first solenoid is used to sharply focus the incoming beam on a fast moving target. The second increases the angular acceptance of the beam line downstream the target for charged reaction products. Calculations show that from a .4mm diameter beam spot on the target, an acceptance angle of up to 80 mrad will be reached without significant emittance growth due to aberration effects. Technical aspects of that project are then presented concerning both the solenoids and the cryogenic devices as well as the solid target

  9. Image acceleration in parallel magnetic resonance imaging by means of metamaterial magnetoinductive lenses

    Directory of Open Access Journals (Sweden)

    Manuel J. Freire

    2012-06-01

    Full Text Available Parallel Magnetic Resonance imaging (pMRI is an image acceleration technique which takes advantage of localized sensitivities of multiple receivers. In this letter, we show that metamaterial lenses based on capacitively-loaded rings can provide higher localization of coil sensitivities compared to conventional loop designs. Several lens designs are systematically analyzed in order to find the structure providing higher signal-to-noise-ratio. The magnetoinductive (MI lens has been found to be the optimum structure and an experiment is developed to show it. The ability of the MI lens for pMRI is investigated by means of the parameter known in the MRI community as g-Factor.

  10. Effect of adhered bacteria on the binding of Acanthamoeba to hydrogel lenses.

    Science.gov (United States)

    Gorlin, A I; Gabriel, M M; Wilson, L A; Ahearn, D G

    1996-05-01

    To determine the effect of Pseudomonas aeruginosa and Staphylococcus epidermidis on the binding of Acanthamoeba species to hydrogel lenses. Cells of amebae and bacteria were incubated with different types of hydrogel lenses. Densities of amebae that were bound to the lenses after rinsing were determined from direct counts with a cell detachment procedure and from scintillation counts of cells, which were radiolabeled with tritiated leucine. With both methods, amebae showed significantly increased binding to hydrogel lenses with attached P aeruginosa. The numbers of amebae that were retained on lenses with attached S epidermidis were not significantly different from those that were retained on lenses without bacteria. The binding of amebae to unworn hydrogel lenses, in contrast to the irreversible adherence of P aeruginosa, was tenuous. The binding of Acanthamoeba species to unworn hydrogel lenses was tenuous and appeared to be related to water content, surface tensions, and ionic charge. The presence of adhered P aeruginosa on the hydrogel lenses facilitated the binding of Acanthamoeba species. The cocontamination of lens systems with bacteria (eg, P aeruginosa) may be a prime factor in the development of amebic keratitis.

  11. Fabricating low cost and high performance elastomer lenses using hanging droplets.

    Science.gov (United States)

    Lee, W M; Upadhya, A; Reece, P J; Phan, Tri Giang

    2014-05-01

    Existing methods for low cost lenses using parallel mold stamping and high temperature reflow requires complex engineering controls to produce high quality lenses. These manufacturing techniques rely on expensive equipment. In this paper, we propose a low cost (technique heralds a new paradigm in the manufacture of low cost, high performance optical lenses for the masses. Using these lenses, we were able to transform an ordinary commercial smartphone camera into a low-cost digital dermascope (60x magnification) that can readily visualize microscopic structures on skin such as sweat pores.

  12. Scleral Lenses in the Management of Corneal Irregularity and Ocular Surface Disease.

    Science.gov (United States)

    Shorter, Ellen; Harthan, Jennifer; Nau, Cherie B; Nau, Amy; Barr, Joseph T; Hodge, David O; Schornack, Muriel M

    2017-09-29

    To describe current practice patterns regarding the use of scleral lens therapy in the management of corneal irregularity and ocular surface disease among eye care providers who fit scleral lenses. The Scleral Lenses in Current Ophthalmic Practice: an Evaluation (SCOPE) study group conducted an electronic survey of eye care providers from January 15 to March 31, 2015. Respondents ranked management options for corneal irregularity in the order in which they would generally consider their use. Respondents also ranked options for the management of ocular surface disease in the order in which they would use each of the treatments. Results for each option were analyzed as percentage first-place ranking; percentage first-, second-, or third-place ranking; and mean rank score. Survey responses were obtained from 723 providers who had fit 5 or more scleral lenses. Of these respondents, 629 ranked options for management of corneal irregularity and 612 ranked options for management of ocular surface disease. Corneal rigid gas-permeable lenses were the first option for management of corneal irregularity for 44% of respondents, and scleral lenses were the first option for 34% of respondents. Lubricant drops were the first therapeutic recommendation for ocular surface disease for 84% of respondents, and scleral lenses were ranked first by 6% of respondents. Scleral lenses rank second only to corneal rigid gas-permeable lenses for management of corneal irregularity. Scleral lenses are generally considered after other medical intervention and before surgery for the management of ocular surface disease.

  13. Influence of Tear Protein Deposition on the Oxygen Permeability of Soft Contact Lenses

    Directory of Open Access Journals (Sweden)

    Se Eun Lee

    2017-01-01

    Full Text Available Purpose. To investigate the effect of tear protein deposition on the change in oxygen permeability (Dk of soft contact lenses (SCL. Methods. Three hydrogel lenses (polymacon, nelfilcon A, and etafilcon A and two silicon hydrogel lenses (lotrafilcon A and balafilcon A were investigated. Etafilcon A lenses were incubated in artificial tear solution for 1, 6, 12, and 48 h, whereas the other SCL were incubated for 1, 3, 7, and 14 days. Oxygen permeability was measured using the polarographic method, and lenses were stacked in four layers to correct the boundary effect. Results. The Dk of all investigated SCL was decreased by the protein deposition. Silicone hydrogel lenses showed a smaller deposition of artificial tear proteins than conventional hydrogel lenses. However, their Dk was reduced twofold than those of 3 conventional hydrogel lenses when compared at the same level of protein deposition. Despite a large amount of total deposited protein in etafilcon A lenses, their Dk was more stable than other SCL. Conclusions. From the results, it was revealed that the Dk of SCL is different from the value provided by manufacturers because of the tear protein deposition on surface and/or in pore of SCL; however, the degree of Dk change in SCL was not simply correlated with the amount of tear protein deposition. Thus, it is considered that the correlation between tear protein deposition and properties of lens materials affects Dk change.

  14. Image D Of Huchra's Lensed Quasar: Waiting For The Other Shoe To Drop

    Science.gov (United States)

    Pooley, David

    2015-09-01

    In mid-2013, image D of Huchra's Lens began fading precipitously in the optical (as seen by OGLE). One expects corresponding brightness changes in X-rays, as the X-ray region is thought to be smaller, by a factor of 4, than the optical continuum region (Mosquera et al), but with the changes occurring more rapidly. At the start of the 2014 OGLE season (MJD 56826), image D was 0.7 mag fainter than in mid-2013. Our analysis of archival Chandra data shows that there was no X-ray drop on MJD 56815 compared to Chandra data from mid- to late-2013. This is somewhat surprising, and it would be even more surprising if image D were still as bright as on MJD 56815, given the continuing decline in the optical (during 2015, image D had fallen 2 mag below its mid-2013 level); this would (uncomfortably) imply that the X-rays and optical come from separate non-concentric regions. We request a 30 ks observation of 2237+0305 to determine whether image D has also fallen by a factor of 6 in X-rays.

  15. Reduction of radiation damage on organic material at very low object temperatures in an electron microscope with supraconductive lenses

    International Nuclear Information System (INIS)

    Knapek, E.

    1981-01-01

    As a result of this study, the increase in structure conservation by cooling the object to very low temperatures (cryoprotection) as compared with the conditions at room temperature was higher than the values at low temperatures reached so far by one to two orders of magnitude. The experiments carried out with an electron microscope with supraconductive lenses (SLEM) showed, depending of the organic substance, that in tests with an electron diffraction of about 4.2 K the reduction of radiation damage as compared with room temperature was by a factor between 30 and 350. (orig./PW) [de

  16. Multifocal versus monofocal intraocular lenses after cataract extraction

    Directory of Open Access Journals (Sweden)

    Daniel Calladine

    Full Text Available BACKGROUND: Good unaided distance visual acuity is now a realistic expectation following cataract surgery and intraocular lens (IOL implantation. Near vision, however, still requires additional refractive power, usually in the form of reading glasses. Multiple optic (multifocal IOLs are available which claim to allow good vision at a range of distances. It is unclear whether this benefit outweighs the optical compromises inherent in multifocal IOLs. OBJECTIVES: The objective of this review was to assess the effects of multifocal IOLs, including effects on visual acuity, subjective visual satisfaction, spectacle dependence, glare and contrast sensitivity, compared to standard monofocal lenses in people undergoing cataract surgery. METHODS: Search methods: We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register, The Cochrane Library 2012, Issue 2, MEDLINE (January 1946 to March 2012, EMBASE (January 1980 to March 2012, the metaRegister of Controlled Trials (mRCT (www.controlled-trials.com, ClinicalTrials.gov (www.clinicaltrials.gov and the WHO International Clinical Trials Registry Platform (ICTRP (www.who.int/ictrp/search/en. We did not use any date or language restrictions in the electronic searches for trials. The electronic databases were last searched on 6 March 2012. We searched the reference lists of relevant articles and contacted investigators of included studies and manufacturers of multifocal IOLs for information about additional published and unpublished studies. Selection criteria: All randomised controlled trials comparing a multifocal IOL of any type with a monofocal IOL as control were included. Both unilateral and bilateral implantation trials were included. Data collection and analysis: Two authors collected data and assessed trial quality. Where possible, we pooled data from the individual studies using a random-effects model, otherwise we tabulated data. MAIN RESULTS: Sixteen completed trials

  17. Modelling the line-of-sight contribution in substructure lensing

    Science.gov (United States)

    Despali, Giulia; Vegetti, Simona; White, Simon D. M.; Giocoli, Carlo; van den Bosch, Frank C.

    2018-04-01

    We investigate how Einstein rings and magnified arcs are affected by small-mass dark-matter haloes placed along the line of sight to gravitational lens systems. By comparing the gravitational signature of line-of-sight haloes with that of substructures within the lensing galaxy, we derive a mass-redshift relation that allows us to rescale the detection threshold (i.e. lowest detectable mass) for substructures to a detection threshold for line-of-sight haloes at any redshift. We then quantify the line-of-sight contribution to the total number density of low-mass objects that can be detected through strong gravitational lensing. Finally, we assess the degeneracy between substructures and line-of-sight haloes of different mass and redshift to provide a statistical interpretation of current and future detections, with the aim of distinguishing between cold dark matter and warm dark matter. We find that line-of-sight haloes statistically dominate with respect to substructures, by an amount that strongly depends on the source and lens redshifts, and on the chosen dark-matter model. Substructures represent about 30 percent of the total number of perturbers for low lens and source redshifts (as for the SLACS lenses), but less than 10 per cent for high-redshift systems. We also find that for data with high enough signal-to-noise ratio and angular resolution, the non-linear effects arising from a double-lens-plane configuration are such that one is able to observationally recover the line-of-sight halo redshift with an absolute error precision of 0.15 at the 68 per cent confidence level.

  18. HOW TO FIND GRAVITATIONALLY LENSED TYPE Ia SUPERNOVAE

    Energy Technology Data Exchange (ETDEWEB)

    Goldstein, Daniel A.; Nugent, Peter E. [Department of Astronomy, University of California, Berkeley, CA 94720-3411 (United States)

    2017-01-01

    Type Ia supernovae (SNe Ia) that are multiply imaged by gravitational lensing can extend the SN Ia Hubble diagram to very high redshifts ( z ≳ 2), probe potential SN Ia evolution, and deliver high-precision constraints on H {sub 0}, w , and Ω{sub m} via time delays. However, only one, iPTF16geu, has been found to date, and many more are needed to achieve these goals. To increase the multiply imaged SN Ia discovery rate, we present a simple algorithm for identifying gravitationally lensed SN Ia candidates in cadenced, wide-field optical imaging surveys. The technique is to look for supernovae that appear to be hosted by elliptical galaxies, but that have absolute magnitudes implied by the apparent hosts’ photometric redshifts that are far brighter than the absolute magnitudes of normal SNe Ia (the brightest type of supernovae found in elliptical galaxies). Importantly, this purely photometric method does not require the ability to resolve the lensed images for discovery. Active galactic nuclei, the primary sources of contamination that affect the method, can be controlled using catalog cross-matches and color cuts. Highly magnified core-collapse SNe will also be discovered as a byproduct of the method. Using a Monte Carlo simulation, we forecast that the Large Synoptic Survey Telescope can discover up to 500 multiply imaged SNe Ia using this technique in a 10 year z -band search, more than an order of magnitude improvement over previous estimates. We also predict that the Zwicky Transient Facility should find up to 10 multiply imaged SNe Ia using this technique in a 3 year R -band search—despite the fact that this survey will not resolve a single system.

  19. Predicting estimates of oxygen transmissibility for scleral lenses.

    Science.gov (United States)

    Michaud, Langis; van der Worp, Eef; Brazeau, Daniel; Warde, Richard; Giasson, Claude J

    2012-12-01

    Although scleral contact lenses are prescribed with increasing frequency, little is known about their long-term effects on ocular physiology. The main goal of this paper is to predict values of oxygen transmissibility of scleral lens systems by applying the concept of resistors in series to parameters characteristic of current scleral lenses. A second aim is to find the maximal lens and post-lens tear layer thickness combinations above which hypoxia-induced corneal swelling would be found. Theoretical calculations were used to predict the oxygen transmissibility of scleral lens systems, considering several material permeabilities (Dks 100-170), varying lens thicknesses (250-500 μm), the known tear permeability (Dk of 80) and expected post-lens tear layer thicknesses (100-400 μm). The Holden-Mertz Dk/t criteria of 24 Fatt units for the central cornea and the Harvitt-Bonanno criteria of 35 Fatt units for the limbal area were used as reference points. Our calculations of oxygen transmissibility, with varying tear layer and lens thicknesses, ranged from 10 to 36.7 at the scleral lens centers and from 17.4 to 62.6 at the peripheries. Our calculations of maximum central lens thicknesses show a practical range of 250-495 μm, in conjunction with a post-lens tear layer thickness of 100-250 μm. Our computations show that most modern scleral lenses, with recommended fitting techniques, should lead to some level of hypoxia-induced corneal swelling. Recommendations are made to minimize hypoxia-induced corneal swelling: highest Dk available (>150) lens with a maximal central thickness of 250 μm and fitted with a clearance that does not exceed 200 μm. Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  20. Effect of time and washing on the adhesion of Acanthamoeba to extended wear disposable hydrogel contact lenses.

    Science.gov (United States)

    Ramachandran, L; Janakiraman, D; Sharma, S; Rao, G N

    1997-04-01

    This study was undertaken to determine the extent of adhesion of cysts and trophozoites of Acanthamoeba to worn disposable hydrogel lenses and to study the effect of time, lens material, and washing on the adhesion. Etafilcon A (58% water content) and Polymacon (38% water content) lenses worn on a 6 night extended wear basis and collected aseptically in PBS pH 7.2, were used for the study. Unworn lenses of the same materials were used as controls. Segments of lenses were incubated in Acanthamoeba suspension (cysts and trophozoites) and examined at 0, 5, and 24 hours, either washed or unwashed, for adherent Acanthamoeba. The amoebae adherent per square mm surface of the lens were enumerated. Levels of adhesion in various groups were compared using Wilcoxon sign rank test. At 0 hours, unwashed worn Polymacon lenses showed significantly greater adherence than Etafilcon A lenses compared to the controls (P = 0.0469). However, there was no difference at 5 and 24 hours exposure time between the lenses. At 24 hours the adhesion of Acanthamoeba was greater for washed worn lenses of both types compared to washed lenses of controls (P = 0.002, 0.012). Amoebae adhered with equal affinity to both types of lenses but adhered with greater affinity to worn lenses than unworn lenses. Adhesion of Acanthamoeba to worn disposable lenses may be a factor in the pathogenesis of Acanthamoeba keratitis in disposable lens wearers.

  1. Effect of yellow-tinted lenses on visual attributes related to sports activities.

    Science.gov (United States)

    Kohmura, Yoshimitsu; Murakami, Shigeki; Aoki, Kazuhiro

    2013-03-01

    The purpose of this study was to clarify the effect of colored lenses on visual attributes related to sports activities. The subjects were 24 students (11 females, 13 males; average age 21.0 ±1.2 years) attending a sports university. Lenses of 5 colors were used: colorless, light yellow, dark yellow, light gray, and dark gray. For each lens, measurements were performed in a fixed order: contrast sensitivity, dynamic visual acuity, depth perception, hand-eye coordination and visual acuity and low-contrast visual acuity. The conditions for the measurements of visual acuity and low-contrast visual acuity were in the order of Evening, Evening+Glare, Day, and Day+Glare. There were no significant differences among lenses in dynamic visual acuity and depth perception. For hand-eye coordination, time was significantly shorter with colorless than dark gray lenses. Contrast sensitivity was significantly higher with colorless, light yellow, and light gray lenses than with dark yellow and dark gray lenses. The low-contrast visual acuity test in the Day+Glare condition showed no significant difference among the lenses. In the Evening condition, low-contrast visual acuity was significantly higher with colorless and light yellow lenses than with dark gray lenses, and in the Evening+Glare condition, low-contrast visual acuity was significantly higher with colorless lenses than with the other colors except light yellow. Under early evening conditions and during sports activities, light yellow lenses do not appear to have an adverse effect on visual attributes.

  2. Effect of xylose on the synthesis of phosphorylcholine and phosphorylethanolamine in rat lenses.

    Science.gov (United States)

    Jernigan, H M; Ekambaram, M C; Blum, P S; Blanchard, M S

    1993-03-01

    Choline, an essential phospholipid precursor, enters the lens by a facilitated transport system and is phosphorylated to form phosphorylcholine (P-choline). Intact lenses incubated with [3H]choline accumulate both [3H]choline and P-[3H]choline. The rate and extent of this accumulation have been used to study the effects of osmotic or oxidative cataractogenic stress, and also to test the ability of compounds to protect lenses from stress-related damage. The initial effect of oxidative stress on choline metabolism is decreased choline transport, but the mechanism by which osmotic stress affects the accumulation of [3H]choline is not understood. The effects of osmotic and oxidative stress on choline influx and metabolism were compared in rat lenses incubated in TC-199 medium. After osmotic stress by incubation with 30 mM xylose for up to 24 hr, lenses accumulated the same amount of radiolabel as controls during a 30 min pulse with [3H]choline. However, if the lenses were exposed to [3H]choline for 6 hr so that accumulation of radiolabel in the lenses was limited by the rate of P-choline synthesis, xylose treated lenses accumulated less choline than controls. Separation of the lenticular radiolabel into [3H]choline and P-[3H]choline confirmed that xylose decreased synthesis of P-choline, although adequate unphosphorylated [3H]choline was available in the lenses. A decrease in P-[3H]ethanolamine synthesis was also seen in xylose-treated lenses incubated with [3H]ethanolamine. Ethanolamine can enter lenses by a non-saturable process which is not dependent upon a transporter. Although xylose decreased P-choline synthesis in intact lenses, neither xylose nor xylitol inhibited choline kinase in lens homogenates.(ABSTRACT TRUNCATED AT 250 WORDS)

  3. [Scheimpflug photography for the examination of phakic intraocular lenses].

    Science.gov (United States)

    Baumeister, M

    2014-10-01

    High myopia phakic intraocular lenses (IOL) have become an established means of surgical correction for high ametropia. Scheimpflug photography is one of the methods which are frequently applied for postoperative examination of the implants. Results from published studies employing Scheimpflug photography for examination of anterior chamber angle-fixated, iris-fixated and sulcus-fixated phakic IOLs were evaluated. In several published studies Scheimpflug photography was used to examine the position of the implant and opacification of the crystalline lens. The results provided valuable evidence for the improvement of phakic IOL design. Scheimpflug photography offers an easy to use, rapid non-contact examination of phakic IOLs.

  4. A Conceptual and Cultural History of Gravitational Lensing

    Science.gov (United States)

    Valls-Gabaud, D.

    2009-08-01

    By analysing the early ideas on the bending of light due to a gravitational attraction, which led to the concept of gravitational lenses, we attempt to present an undistorted historical and cultural perspective of the subject. We show that, contrary to a widespread belief, Newton did not ponder on this topic, and that the earliest thoughts possibly come from Marat and Cavendish. We briefly review the contributions by Soldner, Chwolson and Einstein and focus on the rôle of F. Link, who was undoubtedly the pioneer of the subject.

  5. Planck 2013 results. XVIII. Gravitational lensing-infrared background correlation

    CERN Document Server

    Ade, P.A.R.; Armitage-Caplan, C.; Arnaud, M.; Ashdown, M.; Atrio-Barandela, F.; Aumont, J.; Baccigalupi, C.; Banday, A.J.; Barreiro, R.B.; Bartlett, J.G.; Basak, S.; Battaner, E.; Benabed, K.; Benoit, A.; Benoit-Levy, A.; Bernard, J.P.; Bersanelli, M.; Bethermin, M.; Bielewicz, P.; Bobin, J.; Bock, J.J.; Bonaldi, A.; Bond, J.R.; Borrill, J.; Bouchet, F.R.; Boulanger, F.; Bridges, M.; Bucher, M.; Burigana, C.; Butler, R.C.; Cardoso, J.F.; Catalano, A.; Challinor, A.; Chamballu, A.; Chiang, L.Y.; Chiang, H.C.; Christensen, P.R.; Church, S.; Clements, D.L.; Colombi, S.; Colombo, L.P.L.; Couchot, F.; Coulais, A.; Crill, B.P.; Curto, A.; Cuttaia, F.; Danese, L.; Davies, R.D.; de Bernardis, P.; de Rosa, A.; de Zotti, G.; Delabrouille, J.; Delouis, J.M.; Desert, F.X.; Diego, J.M.; Dole, H.; Donzelli, S.; Dore, O.; Douspis, M.; Dupac, X.; Efstathiou, G.; Ensslin, T.A.; Eriksen, H.K.; Finelli, F.; Forni, O.; Frailis, M.; Franceschi, E.; Galeotta, S.; Ganga, K.; Giard, M.; Giardino, G.; Giraud-Heraud, Y.; Gonzalez-Nuevo, J.; Gorski, K.M.; Gratton, S.; Gregorio, A.; Gruppuso, A.; Gudmundsson, J.E.; Hansen, F.K.; Hanson, D.; Harrison, D.; Henrot-Versille, S.; Hernandez-Monteagudo, C.; Herranz, D.; Hildebrandt, S.R.; Hivon, E.; Hobson, M.; Holmes, W.A.; Hornstrup, A.; Hovest, W.; Huffenberger, K.M.; Jaffe, T.R.; Jaffe, A.H.; Jones, W.C.; Juvela, M.; Keihanen, E.; Keskitalo, R.; Kisner, T.S.; Kneissl, R.; Knoche, J.; Knox, L.; Kunz, M.; Kurki-Suonio, H.; Lacasa, F.; Lagache, G.; Lahteenmaki, A.; Lamarre, J.M.; Lasenby, A.; Laureijs, R.J.; Lawrence, C.R.; Leonardi, R.; Leon-Tavares, J.; Lesgourgues, J.; Liguori, M.; Lilje, P.B.; Linden-Vornle, M.; Lopez-Caniego, M.; Lubin, P.M.; Macias-Perez, J.F.; Maffei, B.; Maino, D.; Mandolesi, N.; Maris, M.; Marshall, D.J.; Martin, P.G.; Martinez-Gonzalez, E.; Masi, S.; Matarrese, S.; Matthai, F.; Mazzotta, P.; Melchiorri, A.; Mendes, L.; Mennella, A.; Migliaccio, M.; Mitra, S.; Miville-Deschenes, M.A.; Moneti, A.; Montier, L.; Morgante, G.; Mortlock, D.; Munshi, D.; Naselsky, P.; Nati, F.; Natoli, P.; Netterfield, C.B.; Norgaard-Nielsen, H.U.; Noviello, F.; Novikov, D.; Novikov, I.; Osborne, S.; Oxborrow, C.A.; Paci, F.; Pagano, L.; Pajot, F.; Paoletti, D.; Patanchon, G.; Perdereau, O.; Perotto, L.; Perrotta, F.; Piacentini, F.; Piat, M.; Pierpaoli, E.; Pietrobon, D.; Plaszczynski, S.; Pointecouteau, E.; Polenta, G.; Ponthieu, N.; Popa, L.; Poutanen, T.; Pratt, G.W.; Prezeau, G.; Prunet, S.; Puget, J.L.; Rachen, J.P.; Rebolo, R.; Reinecke, M.; Remazeilles, M.; Renault, C.; Ricciardi, S.; Riller, T.; Ristorcelli, I.; Rocha, G.; Rosset, C.; Roudier, G.; Rowan-Robinson, M.; Rusholme, B.; Sandri, M.; Santos, D.; Savini, G.; Scott, D.; Seiffert, M.D.; Serra, P.; Shellard, E.P.S.; Spencer, L.D.; Starck, J.L.; Stolyarov, V.; Stompor, R.; Sudiwala, R.; Sunyaev, R.; Sureau, F.; Sutton, D.; Suur-Uski, A.S.; Sygnet, J.F.; Tauber, J.A.; Tavagnacco, D.; Terenzi, L.; Toffolatti, L.; Tomasi, M.; Tristram, M.; Tucci, M.; Tuovinen, J.; Valenziano, L.; Valiviita, J.; Van Tent, B.; Vielva, P.; Villa, F.; Vittorio, N.; Wade, L.A.; Wandelt, B.D.; White, S.D.M.; Yvon, D.; Zacchei, A.; Zonca, A.

    2014-01-01

    The multi-frequency capability of the Planck satellite provides information both on the integrated history of star formation (via the cosmic infrared background, or CIB) and on the distribution of dark matter (via the lensing effect on the cosmic microwave background, or CMB). The conjunction of these two unique probes allows us to measure directly the connection between dark and luminous matter in the high redshift (1 1. We measure directly the SFR density with around 2 sigma significance for three redshift bins between z=1 and 7, thus opening a new window into the study of the formation of stars at early times.

  6. Material properties of various intraocular lenses in an experimental study.

    Science.gov (United States)

    Tehrani, Mana; Dick, H Burkhard; Wolters, Beate; Pakula, Tadeusz; Wolf, Evan

    2004-01-01

    With the recent introduction of small-incision cataract surgery, requirements for intraocular lens (IOL) flexibility, strength and hydrophilicity have rapidly evolved. The IOL surface, however, remains a critical factor influencing uveal biocompatibility. To objectively quantify factors of material properties of various IOLs using contact angle measurements, differential scanning calorimetry, dynamic-mechanical measurements and scanning electron microscopy. In our study, 17 currently available IOLs were investigated using contact angle measurements to assess hydrophilicity and biocompatibility, as well as differential scanning calorimetry for the estimation of glass transition temperature. Mechanical capacity and flexibility were investigated using dynamic-mechanical measurements. Additional analysis of the IOL surface was performed using scanning electron microscopy. The contact angle measurements of the studied IOLs revealed similar values within each group. The silicone IOLs had values between 106 and 119 degrees. The PMMA IOLs were found to have a narrower range of values, between 73.2 and 75.5 degrees. Lenses made of hydrogel had values between 59.2 and 69.1 degrees. The heparin-modified surface showed the lowest contact angle of 56.5 degrees. The glass transition temperature was determined by dynamic differential scanning calorimetry. The resulting values were between 118.8 and 113.5 degrees C for PMMA IOLs, 15.5 and 14.0 degrees C for acrylic IOLs, and -91.7 and -119.6 degrees C for silicone IOLs. The dynamic-mechanical measurements revealed that PMMA lenses manifested characteristics similar to glass, whereas silicone lenses had characteristics similar to rubber. Acrylic lenses were between rubber and glass. Scanning electron microscopy revealed smooth dispersion of fibrin on hydrophobic IOLs and a relative lack of fibrin adhesion on hydrophilic materials. These results demonstrate that material properties of various IOL materials are consistent within

  7. Optical loss due to diffraction by concentrator Fresnel lenses

    International Nuclear Information System (INIS)

    Hornung, Thorsten; Nitz, Peter

    2014-01-01

    Fresnel lenses are widely used in concentrating photovoltaic (CPV) systems as a primary optical element. They focus sunlight on small solar cells or on the entrance apertures of secondary optical elements. A Fresnel lens consists of several prism rings and diffraction by these prism rings is unavoidable. Some of the light that would reach a designated target area according to geometric optics will miss it due to diffraction. This diffraction loss may be of relevant magnitude for CPV applications. The results of published analytical calculations are evaluated, discussed, and compared to computer simulations and measurements

  8. Efficient simulation of autofluorescence effects in microscopic lenses

    DEFF Research Database (Denmark)

    Gross, Herbert; Rodenko, Olga; Esslinger, Moritz

    2015-01-01

    The use of fluorescence in microscopy is a well known technology today. Due to the autofluorescence of the materials of the optical system components, the contrast of the images is degraded. The calculation of autofluorescense usually is performed by brute force methods as volume scattering...... be performed properly. Some necessary approximations produce negligible errors. The improvement in run time is in the range of 104 . It is shown with some practical examples of microscopic lenses, that the results are comparable with conventional methods. The limitations and the consequences for questions...

  9. Lenses on Reading An Introduction to Theories and Models

    CERN Document Server

    Tracey, Diane H

    2012-01-01

    This widely adopted text explores key theories and models that frame reading instruction and research. Readers learn why theory matters in designing and implementing high-quality instruction and research; how to critically evaluate the assumptions and beliefs that guide their own work; and what can be gained by looking at reading through multiple theoretical lenses. For each theoretical model, classroom applications are brought to life with engaging vignettes and teacher reflections. Research applications are discussed and illustrated with descriptions of exemplary studies. New to This Edition

  10. [Cataract extraction with intraocular lenses in a teaching hospital].

    Science.gov (United States)

    Jara, R; Charlín, R; Schweikart, A; Stoppel, J; Maul, E

    1991-07-01

    One hundred and twelve primary posterior chamber intraocular lens implants from a series of 560 eyes operated on at the Eye Service of Hospital Salvador in Santiago, Chile, were analyzed to determine the postoperative visual acuity. The follow up time varied between 3 and 26 months. Lenses were implanted by experienced ophthalmologists and residents in training. Visual acuity was 0.5 or better in 79.5% of cases. The postoperative visual acuity varied with age, being worse in patients over 70 years old.

  11. The impact of ΛCDM substructure and baryon-dark matter transition on the image positions of quad galaxy lenses

    Science.gov (United States)

    Gomer, Matthew R.; Williams, Liliya L. R.

    2018-04-01

    The positions of multiple images in galaxy lenses are related to the galaxy mass distribution. Smooth elliptical mass profiles were previously shown to be inadequate in reproducing the quad population. In this paper, we explore the deviations from such smooth elliptical mass distributions. Unlike most other work, we use a model-free approach based on the relative polar image angles of quads, and their position in 3D space with respect to the fundamental surface of quads (FSQ). The FSQ is defined by quads produced by elliptical lenses. We have generated thousands of quads from synthetic populations of lenses with substructure consistent with Lambda cold dark matter (ΛCDM) simulations, and found that such perturbations are not sufficient to match the observed distribution of quads relative to the FSQ. The result is unchanged even when subhalo masses are increased by a factor of 10, and the most optimistic lensing selection bias is applied. We then produce quads from galaxies created using two components, representing baryons and dark matter. The transition from the mass being dominated by baryons in inner radii to being dominated by dark matter in outer radii can carry with it asymmetries, which would affect relative image angles. We run preliminary experiments using lenses with two elliptical mass components with non-identical axial ratios and position angles, perturbations from ellipticity in the form of non-zero Fourier coefficients a4 and a6, and artificially offset ellipse centres as a proxy for asymmetry at image radii. We show that combination of these effects is a promising way of accounting for quad population properties. We conclude that the quad population provides a unique and sensitive tool for constraining detailed mass distribution in the centres of galaxies.

  12. Extended latanoprost release from commercial contact lenses: in vitro studies using corneal models.

    Directory of Open Access Journals (Sweden)

    Saman Mohammadi

    Full Text Available In this study, we compared, for the first time, the release of a 432 kDa prostaglandin F2a analogue drug, Latanoprost, from commercially available contact lenses using in vitro models with corneal epithelial cells. Conventional polyHEMA-based and silicone hydrogel soft contact lenses were soaked in drug solution (131 μg = ml solution in phosphate buffered saline. The drug release from the contact lens material and its diffusion through three in vitro models was studied. The three in vitro models consisted of a polyethylene terephthalate (PET membrane without corneal epithelial cells, a PET membrane with a monolayer of human corneal epithelial cells (HCEC, and a PET membrane with stratified HCEC. In the cell-based in vitro corneal epithelium models, a zero order release was obtained with the silicone hydrogel materials (linear for the duration of the experiment whereby, after 48 hours, between 4 to 6 μg of latanoprost (an amount well within the range of the prescribed daily dose for glaucoma patients was released. In the absence of cells, a significantly lower amount of drug, between 0.3 to 0.5 μg, was released, (p <0:001. The difference observed in release from the hydrogel lens materials in the presence and absence of cells emphasizes the importance of using an in vitro corneal model that is more representative of the physiological conditions in the eye to more adequately characterize ophthalmic drug delivery materials. Our results demonstrate how in vitro models with corneal epithelial cells may allow better prediction of in vivo release. It also highlights the potential of drug-soaked silicone hydrogel contact lens materials for drug delivery purposes.

  13. Effect of patient wear and extent of protein deposition on adsorption of Acanthamoeba to five types of hydrogel contact lenses.

    Science.gov (United States)

    Simmons, P A; Tomlinson, A; Connor, R; Hay, J; Seal, D V

    1996-06-01

    Attachment of Acanthamoeba species to hydrogel contact lenses is a possible route of infection in Acanthamoeba keratitis. In this study, Acanthamoeba adsorption was compared with extent of lens deposition in worn lenses of different hydrogel polymers. After wear, lenses (80 lenses of 5 different types) were analyzed for total protein, surface area of deposition, and Acanthamoeba castellani trophozoite and cyst adsorption. Adsorption of Acanthamoeba trophozoites to worn lenses was greater than adsorption to unworn lenses for four of the five lens polymers (p 0.05). Adsorption was affected by both the water content and ionicity of the lens polymer. These results show that adsorption of Acanthamoeba to worn hydrogel contact lenses is greater than or equal to adsorption to unworn lenses.

  14. A gravitationally lensed quasar with quadruple images separated by 14.62 arcseconds.

    Science.gov (United States)

    Inada, Naohisa; Oguri, Masamune; Pindor, Bartosz; Hennawi, Joseph F; Chiu, Kuenley; Zheng, Wei; Ichikawa, Shin-Ichi; Gregg, Michael D; Becker, Robert H; Suto, Yasushi; Strauss, Michael A; Turner, Edwin L; Keeton, Charles R; Annis, James; Castander, Francisco J; Eisenstein, Daniel J; Frieman, Joshua A; Fukugita, Masataka; Gunn, James E; Johnston, David E; Kent, Stephen M; Nichol, Robert C; Richards, Gordon T; Rix, Hans-Walter; Sheldon, Erin Scott; Bahcall, Neta A; Brinkmann, J; Ivezić, Zeljko; Lamb, Don Q; McKay, Timothy A; Schneider, Donald P; York, Donald G

    2003-12-18

    Gravitational lensing is a powerful tool for the study of the distribution of dark matter in the Universe. The cold-dark-matter model of the formation of large-scale structures (that is, clusters of galaxies and even larger assemblies) predicts the existence of quasars gravitationally lensed by concentrations of dark matter so massive that the quasar images would be split by over 7 arcsec. Numerous searches for large-separation lensed quasars have, however, been unsuccessful. All of the roughly 70 lensed quasars known, including the first lensed quasar discovered, have smaller separations that can be explained in terms of galaxy-scale concentrations of baryonic matter. Although gravitationally lensed galaxies with large separations are known, quasars are more useful cosmological probes because of the simplicity of the resulting lens systems. Here we report the discovery of a lensed quasar, SDSS J1004 + 4112, which has a maximum separation between the components of 14.62 arcsec. Such a large separation means that the lensing object must be dominated by dark matter. Our results are fully consistent with theoretical expectations based on the cold-dark-matter model.

  15. Dioptrics of the facet lenses in the dorsal rim area of the cricket Gryllus bimaculatus

    NARCIS (Netherlands)

    Ukhanov, KY; Leertouwer, HL; Gribakin, FG; Stavenga, DG

    1996-01-01

    1. The optics of the corneal facet lenses from the dorsal rim area (DRA) and from the dorso-lateral areas (DA) of the compound eye of the cricket Gryllus bimaculatus were studied. 2. The DRA of the cricket eye contains quite normally shaped facet lenses. The diameter of the facet lens in the DA is

  16. Characterization of sand lenses and their role for subsurface transport in low-permeability clay tills

    DEFF Research Database (Denmark)

    Kessler, Timo Christian; Klint, K. E.; Nilsson, B.

    2011-01-01

    Glacial sediments dominate large parts of the geological topology in Denmark. They predominantly consist of lowpermeability tills, but fractures and sand-lenses constitute zones of enhanced permeability facilitating preferential flow. This study focuses on characterization of sand deposits with r...... the sand lenses in hydro-geological models to successfully characterize subsurface flow and transport, e.g. for remediation activities....

  17. Cosmetic Cleansing Oil Absorption by Soft Contact Lenses in Dry and Wet Conditions.

    Science.gov (United States)

    Tsukiyama, Junko; Miyamoto, Yuko; Kodama, Aya; Fukuda, Masahiko; Shimomura, Yoshikazu

    2017-09-01

    Previous reports showed that cosmetic cleansing oil for removing makeup, which contains mineral oil and surfactant, can deform some silicone hydrogel contact lenses (SHCLs) when applied directly to the lenses, although plasma-coated SHCLs (lotrafilcon A and B) were not affected. In the present study, we investigated hydrogel lenses and SHCLs in both wet and dry conditions. Several brands of hydrogel and SHCLs were immersed in a cleansing oil solution containing Sudan Black B for 5 min under wet and dry conditions. The lenses under the wet condition were simply picked up from the saline, whereas those under the dry condition were blotted with paper wipes. After immersing, the excess solution remaining on the lenses was removed by finger rubbing with a multipurpose solution. The lenses were then examined using a stereomicroscope, and their mean brightness was measured and compared. The cosmetic cleansing oil was not absorbed by the hydrogel lenses under wet or dry conditions. However, four of seven brands of SHCLs absorbed the cosmetic cleansing oil under both conditions (dry and wet), whereas asmofilcon A absorbed it only under the dry condition. Lotrafilcon B and delefilcon A did not absorb cleansing oil even under the dry condition. Hydrogel lenses resist cosmetic cleansing oil. However, SHCLs have different degrees of resistance depending on the lens material. Some SHCLs absorbed cosmetic cleansing oil more under dry conditions than under wet conditions.

  18. Planck 2013 results. XVII. Gravitational lensing by large-scale structure

    DEFF Research Database (Denmark)

    Ade, P. A. R.; Aghanim, N.; Armitage-Caplan, C.

    2013-01-01

    On the arcminute angular scales probed by Planck, the cosmic microwave background (CMB) anisotropies are gently perturbed by gravitational lensing. Here we present a detailed study of this eect, detecting lensing independently in the 100, 143, and 217 GHz frequency bands with an overall significa...

  19. Recovery of the water content of hydrogel contact lenses after use.

    Science.gov (United States)

    Cabrera, Josefa Velasco; Velasco, María José García

    2005-09-01

    The aim of the present study is to determine the amount and time of water-content recovery of ionic contact lenses (Surevue and Acuvue) and non-ionic contact lenses (Soflens 38, Soflens 66 and Optima 38) when submerged in maintenance solution for 9 h. Using a hand-held refractometer, we measured the water content of the lenses upon removal from the eye, and after 15, 30, 45 min, 1, 2 and 9 h in soaking solution. Both ionic lenses presented pre-wear water content of 58%, while two of the non-ionic ones (Soflens 38 and Optima 38) registered 38.6% and the third (Soflens 66) had 66%. We found a significant increase (p 0.05) between ionic and non-ionic lenses, although the non-ionic lenses reached slightly higher water-content values at all the times studied. These results indicate that when the refractometer technique is used to measure water content, the lens types used in this study regain their initial water-content values after 9 h in soaking solution. These data indicate the time needed for hydrogel contact lenses to reach their maximum water content after removal from the eye and submersion in maintenance solution. By ensuring maximum water content and minimum reduction of oxygen for the cornea, the specialist can help avoid clinical signs and symptoms related to low water content in the lenses.

  20. UVB-protective properties of contact lenses with intended use in photoresponsive eyelid dermatoses.

    Science.gov (United States)

    Depry, Jennifer; Golding, Robert; Szczotka-Flynn, Loretta; Dao, Harry; Baron, Elma; Cooper, Kevin

    2013-10-01

    UV-blocking contact lenses were evaluated to determine if they could provide adequate ocular protection during narrowband UVB phototherapy treatment. Theoretical safe exposure durations for the crystalline lens, cornea and conjunctiva were determined. A Cary 500 spectrophometer generated transmittance data for six UV-blocking and two non-UV-blocking contact lenses. An IL-1700 radiometer measured the lenses' radiation transmittance within the NB-UVB phototherapy unit. The lenses were exposed to a 1500-mJ/cm(2) dose of radiation from a 308-nm excimer laser to determine if the radiation would alter their protective properties. Theoretical safe exposure durations for eye structures were calculated using previous human and animal study data. All UV-blocking contact lenses showed less than 1E-7 W/cm(2) of radiation transmittance within the narrowband phototherapy unit. The excimer laser did not significantly alter the lenses' UV-blocking capabilities. The safe exposure durations for the cornea and crystalline lens were greater than 11 min with UV-blocking lenses, and that for the unprotected conjunctiva was approximately 11 s. Some UV-blocking contact lenses potentially provide sufficient ocular protection during narrowband UVB phototherapy treatment, as the crystalline lens and cornea are adequately protected should a patient open his or her eyes for a short time. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Objective and subjective performance of scleral lenses and new advances in scleral lens technologies

    NARCIS (Netherlands)

    Visser, E.S.

    2015-01-01

    Scleral lenses are widely recognized for their ability to markedly improve quality of life and giving back patients their ability to perform daily activities, mainly as a result of restoring visual function and/or reduction of ocular discomfort and pain.Scleral lenses are an important front-line

  2. Technology of Manufacture of the Negative Matrices for Linear Fresnel Lenses

    Science.gov (United States)

    Lapshin, V. V.; Zakharevich, E. M.; Grubyy, S. V.

    2016-04-01

    This article describes the main structural features of negative matrices which are intended for the production of positive copies of linear Fresnel lenses. Linear lenses are used in a space solar energy industry as solar concentrators in the photovoltaic modules. The article covers the essential requirements which are placed on the equipment and technology for the production of such matrices.

  3. Identification of Microorganisms Isolated From Counterfeit and Unapproved Decorative Contact Lenses.

    Science.gov (United States)

    Land, Adrian D; Penno, Katie L; Brzezinski, Jennifer L

    2018-03-01

    All contact lenses (corrective/noncorrective) are considered Class II or Class III medical devices under the Federal Food, Drug, and Cosmetic Act, which also states that contact lenses can only be obtained with a prescription. The Forensic Chemistry Center of the US Food & Drug Administration has examined over 300 decorative, noncorrective contact lenses obtained without a prescription. Our observations indicate that 60% of the counterfeit lenses and 27% of the unapproved lenses examined were positive for microbial contamination. Twenty-nine different brands of noncorrective contact lenses were examined, and 48% of them had at least one sample positive for microbial contamination. Each microorganism was further identified using DNA sequencing. Contaminated contact lenses are associated with numerous health risks, including ocular infections and conjunctivitis leading to permanent visual impairment or blindness. These results support the contention that acquiring contact lenses without a prescription is a considerable threat to consumer health and safety. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  4. Adhesion of Pseudomonas aeruginosa to contact lenses after exposure to multi-purpose lens care solutions

    NARCIS (Netherlands)

    Bruinsma, GM; Van der Mei, HC; Busscher, HJ; de Vries, Jacob

    2001-01-01

    Elemental surface compositions of contact lenses were measured after exposure to different lens care solutions (LCS) using X-ray photoelectron spectroscopy and were related to adhesion and detachment of Pseudomonas aeruginosa. Etafilcon A and polymacon contact lenses, prior to and after exposure to

  5. Observations and analytical modeling of freshwater and rainwater lenses in coastal dune systems

    NARCIS (Netherlands)

    Stuijfzand, Pieter

    2016-01-01

    Observations are reported on (i) groundwater recharge rates under various types of vegetation as measured with megalysimeters in the dunes, (ii) freshwater lenses along the Dutch North Sea coast in the early 1900s, and (iii) rainwater lenses that develop on top of laterally migrating,

  6. Electromagnetic methods for mapping freshwater lenses on Micronesian atoll islands

    Science.gov (United States)

    Anthony, S.S.

    1992-01-01

    The overall shape of freshwater lenses can be determined by applying electromagnetic methods and inverse layered-earth modeling to the mapping of atoll island freshwater lenses. Conductivity profiles were run across the width of the inhabited islands at Mwoakilloa, Pingelap, and Sapwuahfik atolls of the Pohnpei State, Federated States of Micronesia using a dual-loop, frequency-domain, electromagnetic profiling system. Six values of apparent conductivity were recorded at each sounding station and were used to interpret layer conductivities and/or thicknesses. A three-layer model that includes the unsaturated, freshwater, and saltwater zones was used to simulate apparent-conductivity data measured in the field. Interpreted results were compared with chloride-concentration data from monitoring wells and indicate that the interface between freshwater and saltwater layers, defined from electromagnetic data, is located in the upper part of the transition zone, where the chloride-concentration profile shows a rapid increase with depth. The electromagnetic method can be used to interpret the thickness of the freshwater between monitoring wells, but can not be used to interpret the thickness of freshwater from monitoring wells to the margin of an island. ?? 1992.

  7. Constraining unified dark matter models with weak lensing

    Energy Technology Data Exchange (ETDEWEB)

    Camera, S. [Dipartimento di Fisica Generale Amedeo Avogadro, Universita degli Studi di Torino, Torino (Italy); Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Torino, Torino (Italy)

    2010-04-15

    Unified Dark Matter (UDM) models provide an intriguing alternative to Dark Matter (DM) and Dark Energy (DE) through only one exotic component, i.e. a classical scalar field {phi}(t,x). Thanks to a non-canonical kinetic term, this scalar field can mimic both the behaviour of the matter-dominated era at earlier times, as DM do, and the outcoming late-time acceleration, as a cosmological constant DE. Thus, it has been shown that these models can reproduce the same expansion history of the {lambda}CDM concordance model. In this work I review the first prediction of a physical observable, the power spectrum of the weak lensing cosmic convergence (shear). I present the weak lensing signal as predicted by the standard {lambda}CDM model and by a family of viable UDM models parameterized by the late-time sound speed c{sub {infinity}} of the scalar field.last-scattering surface and a series of background galaxies peaked at different redshifts and spread over different redshifts as described by a functional form of their distribution of sources. (Abstract Copyright [2010], Wiley Periodicals, Inc.)

  8. Cusp-core problem and strong gravitational lensing

    International Nuclear Information System (INIS)

    Li Nan; Chen Daming

    2009-01-01

    Cosmological numerical simulations of galaxy formation have led to the cuspy density profile of a pure cold dark matter halo toward the center, which is in sharp contradiction with the observations of the rotation curves of cold dark matter-dominated dwarf and low surface brightness disk galaxies, with the latter tending to favor mass profiles with a flat central core. Many efforts have been devoted to resolving this cusp-core problem in recent years, among them, baryon-cold dark matter interactions are considered to be the main physical mechanisms erasing the cold dark matter (CDM) cusp into a flat core in the centers of all CDM halos. Clearly, baryon-cold dark matter interactions are not customized only for CDM-dominated disk galaxies, but for all types, including giant ellipticals. We first fit the most recent high resolution observations of rotation curves with the Burkert profile, then use the constrained core size-halo mass relation to calculate the lensing frequency, and compare the predicted results with strong lensing observations. Unfortunately, it turns out that the core size constrained from rotation curves of disk galaxies cannot be extrapolated to giant ellipticals. We conclude that, in the standard cosmological paradigm, baryon-cold dark matter interactions are not universal mechanisms for galaxy formation, and therefore, they cannot be true solutions to the cusp-core problem.

  9. The Weak Lensing Masses of Filaments between Luminous Red Galaxies

    Science.gov (United States)

    Epps, Seth D.; Hudson, Michael J.

    2017-07-01

    In the standard model of non-linear structure formation, a cosmic web of dark-matter-dominated filaments connects dark matter haloes. In this paper, we stack the weak lensing signal of an ensemble of filaments between groups and clusters of galaxies. Specifically, we detect the weak lensing signal, using CFHTLenS galaxy ellipticities, from stacked filaments between Sloan Digital Sky Survey (SDSS)-III/Baryon Oscillation Spectroscopic Survey luminous red galaxies (LRGs). As a control, we compare the physical LRG pairs with projected LRG pairs that are more widely separated in redshift space. We detect the excess filament mass density in the projected pairs at the 5σ level, finding a mass of (1.6 ± 0.3) × 1013 M⊙ for a stacked filament region 7.1 h-1 Mpc long and 2.5 h-1 Mpc wide. This filament signal is compared with a model based on the three-point galaxy-galaxy-convergence correlation function, as developed in Clampitt et al., yielding reasonable agreement.

  10. Low-energy beam transport using space-charge lenses

    International Nuclear Information System (INIS)

    Meusel, O.; Bechtold, A.; Pozimski, J.; Ratzinger, U.; Schempp, A.; Klein, H.

    2005-01-01

    Space-charge lenses (SCL) of the Gabor type provide strong cylinder symmetric focusing for low-energy ion beams using a confined nonneutral plasma. They need modest magnetic and electrostatic field strength and provide a short installation length when compared to conventional LEBT-lenses like quadrupoles and magnetic solenoids. The density distribution of the enclosed space charge within the Gabor lens is given by the confinement in transverse and longitudinal directions. In the case of a positive ion beam, the space charge of the confined electron cloud may cause an overcompensation of the ion beam space-charge force and consequently focuses the beam. To investigate the capabilities of an SCL double-lens system for ion beam into an RFQ, a test injector was installed at IAP and put into operation successfully. Furthermore, to study the focusing capabilities of this lens at beam energies up to 500 keV, a high-field Gabor lens was built and installed downstream of the RFQ. Experimental results of the beam injection into the RFQ are presented as well as those of these first bunched beam-focusing tests with the 110 A keV He + beam

  11. Simulation-based marginal likelihood for cluster strong lensing cosmology

    Science.gov (United States)

    Killedar, M.; Borgani, S.; Fabjan, D.; Dolag, K.; Granato, G.; Meneghetti, M.; Planelles, S.; Ragone-Figueroa, C.

    2018-01-01

    Comparisons between observed and predicted strong lensing properties of galaxy clusters have been routinely used to claim either tension or consistency with Λ cold dark matter cosmology. However, standard approaches to such cosmological tests are unable to quantify the preference for one cosmology over another. We advocate approximating the relevant Bayes factor using a marginal likelihood that is based on the following summary statistic: the posterior probability distribution function for the parameters of the scaling relation between Einstein radii and cluster mass, α and β. We demonstrate, for the first time, a method of estimating the marginal likelihood using the X-ray selected z > 0.5 Massive Cluster Survey clusters as a case in point and employing both N-body and hydrodynamic simulations of clusters. We investigate the uncertainty in this estimate and consequential ability to compare competing cosmologies, which arises from incomplete descriptions of baryonic processes, discrepancies in cluster selection criteria, redshift distribution and dynamical state. The relation between triaxial cluster masses at various overdensities provides a promising alternative to the strong lensing test.

  12. Probing the cosmic distance duality relation using time delay lenses

    Energy Technology Data Exchange (ETDEWEB)

    Rana, Akshay; Mahajan, Shobhit; Mukherjee, Amitabha [Department of Physics and Astrophysics, University of Delhi, Delhi 110007 (India); Jain, Deepak [Deen Dayal Upadhyaya College, University of Delhi, Sector-3, Dwarka, New Delhi 110078 (India); Holanda, R.F.L., E-mail: montirana1992@gmail.com, E-mail: djain@ddu.du.ac.in, E-mail: shobhit.mahajan@gmail.com, E-mail: amimukh@gmail.com, E-mail: holanda@uepb.edu.br [Departamento de Física, Universidade Federal de Sergipe, 49100-000, Aracaju—SE (Brazil)

    2017-07-01

    The construction of the cosmic distance-duality relation (CDDR) has been widely studied. However, its consistency with various new observables remains a topic of interest. We present a new way to constrain the CDDR η( z ) using different dynamic and geometric properties of strong gravitational lenses (SGL) along with SNe Ia observations. We use a sample of 102 SGL with the measurement of corresponding velocity dispersion σ{sub 0} and Einstein radius θ {sub E} . In addition, we also use a dataset of 12 two image lensing systems containing the measure of time delay Δ t between source images. Jointly these two datasets give us the angular diameter distance D {sub A} {sub ol} of the lens. Further, for luminosity distance, we use the 740 observations from JLA compilation of SNe Ia. To study the combined behavior of these datasets we use a model independent method, Gaussian Process (GP). We also check the efficiency of GP by applying it on simulated datasets, which are generated in a phenomenological way by using realistic cosmological error bars. Finally, we conclude that the combined bounds from the SGL and SNe Ia observation do not favor any deviation of CDDR and are in concordance with the standard value (η=1) within 2σ confidence region, which further strengthens the theoretical acceptance of CDDR.

  13. Polymer-interaction driven diffusionof eyeshadow in soft contact lenses.

    Science.gov (United States)

    Tavazzi, Silvia; Rossi, Alessandra; Picarazzi, Sara; Ascagni, Miriam; Farris, Stefano; Borghesi, Alessandro

    2017-10-01

    Soft contact lenses used for the correction of ametropia are often made of hydrogel and silicone-hydrogel materials. Since they are placed directly on the surface of the eye and they are hydrated by tears, eye cosmetics can compromise the lens performance and, even worse, can be transported from an external environment to the ocular surface through the contact lens. The diffusion of the dye component of a purple eyeshadow in soft contact lenses of different materials is here evaluated. Diffusivity is found to be typically higher in silicone-hydrogels than in hydrogels. In hydrogels, diffusivity is greater in the case of lower oxygen transmissibility. Despite differences between materials, absorbed mass of dye is much larger (10-100 times) than the expected mass by simple hydration and swelling of the contact lens. The most contaminated materials are also resistant to cleaning solutions. The results indicate that, notwithstanding the complexity of contact lens networks, diffusion of dye is found to follow Fick's law and it is driven by polymer-dye interaction, which governs lens hydration and swelling. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  14. An Electrically Tunable Zoom System Using Liquid Lenses.

    Science.gov (United States)

    Li, Heng; Cheng, Xuemin; Hao, Qun

    2015-12-31

    A four-group stabilized zoom system using two liquid lenses and two fixed lens groups is proposed. We describe the design principle, realization, and the testing of a 5.06:1 zoom system. The realized effective focal length (EFL) range is 6.93 mm to 35.06 mm, and the field of view (FOV) range is 8° to 40°. The system can zoom fast when liquid lens 1's (L₁'s) optical power take the value from 0.0087 mm(-1) to 0.0192 mm(-1) and liquid lens 2's (L₂'s) optical power take the value from 0.0185 mm(-1) to -0.01 mm(-1). Response time of the realized zoom system was less than 2.5 ms, and the settling time was less than 15 ms.The analysis of elements' parameters and the measurement of lens performance not only verify the design principle further, but also show the zooming process by the use of two liquid lenses. The system is useful for motion carriers e.g., robot, ground vehicle, and unmanned aerial vehicles considering that it is fast, reliable, and miniature.

  15. Weak Lensing by Galaxy Clusters: from Pixels to Cosmology

    International Nuclear Information System (INIS)

    Gruen, Daniel

    2015-01-01

    The story of the origin and evolution of our Universe is told, equivalently, by space-time itself and by the structures that grow inside of it. Clusters of galaxies are the frontier of bottom-up structure formation. They are the most massive objects to have collapsed at the present epoch. By that virtue, their abundance and structural parameters are highly sensitive to the composition and evolution of the Universe. The most common probe of cluster cosmology, abundance, uses samples of clusters selected by some observable. Applying a mass-observable relation (MOR), cosmological parameters can be constrained by comparing the sample to predicted cluster abundances as a function of observable and redshift. Arguably, however, cluster probes have not yet entered the era of per cent level precision cosmology. The primary reason for this is our imperfect understanding of the MORs. The overall normalization, the slope of mass vs. observable, the redshift evolution, and the degree and correlation of intrinsic scatters of observables at fixed mass have to be constrained for interpreting abundances correctly. Mass measurement of clusters by means of the differential deflection of light from background sources in their gravitational field, i.e. weak lensing, is a powerful approach for achieving this. This thesis presents new methods for and scientific results of weak lensing measurements of clusters of galaxies. The former include, on the data reduction side, (i) the correction of CCD images for non-linear effects due to the electric fields of accumulated charges and (ii) a method for masking artifact features in sets of overlapping images of the sky by comparison to the median image. Also, (iii) I develop a method for the selection of background galaxy samples based on their color and apparent magnitude that includes a new correction for contamination with cluster member galaxies. The main scientific results are the following. (i) For the Hubble Frontier Field cluster RXC J

  16. Weak Lensing by Galaxy Clusters: from Pixels to Cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Gruen, Daniel [Ludwig Maximilian Univ., Munich (Germany)

    2015-03-11

    The story of the origin and evolution of our Universe is told, equivalently, by space-time itself and by the structures that grow inside of it. Clusters of galaxies are the frontier of bottom-up structure formation. They are the most massive objects to have collapsed at the present epoch. By that virtue, their abundance and structural parameters are highly sensitive to the composition and evolution of the Universe. The most common probe of cluster cosmology, abundance, uses samples of clusters selected by some observable. Applying a mass-observable relation (MOR), cosmological parameters can be constrained by comparing the sample to predicted cluster abundances as a function of observable and redshift. Arguably, however, cluster probes have not yet entered the era of per cent level precision cosmology. The primary reason for this is our imperfect understanding of the MORs. The overall normalization, the slope of mass vs. observable, the redshift evolution, and the degree and correlation of intrinsic scatters of observables at fixed mass have to be constrained for interpreting abundances correctly. Mass measurement of clusters by means of the differential deflection of light from background sources in their gravitational field, i.e. weak lensing, is a powerful approach for achieving this. This thesis presents new methods for and scientific results of weak lensing measurements of clusters of galaxies. The former include, on the data reduction side, (i) the correction of CCD images for non-linear effects due to the electric fields of accumulated charges and (ii) a method for masking artifact features in sets of overlapping images of the sky by comparison to the median image. Also, (iii) I develop a method for the selection of background galaxy samples based on their color and apparent magnitude that includes a new correction for contamination with cluster member galaxies. The main scientific results are the following. (i) For the Hubble Frontier Field cluster RXC J

  17. Optical quality and vision with iris-coloring soft contact lenses.

    Science.gov (United States)

    Ortiz, Carolina; Jiménez, Raimundo

    2014-05-01

    To study the influence of iris-coloring soft contact lenses, designed for changing apparent iris color, on optical quality and vision. Eighty subjects were included in this study. All participants were classified as emmetropic, with monocular best-corrected visual acuity of 20/20 or better. For 40 subjects, we measured the optical quality (aberrations, the Strehl ratio, and the objective scattering index) and visual performance before and after wearing the cosmetic soft contact lenses. We also measured the optical quality and visual performance for the other 40 subjects but with a different kind of lens (fantasy soft contact lenses). Iris-coloring soft contact lenses significantly increased coma-like and total higher-order aberrations and objective scattering index (p Iris-coloring soft contact lenses deteriorate the optical quality and worsen the contrast sensitivity function. Iris-coloring soft contact lens wearers should be informed about the effects on optical quality and visual function.

  18. Constraints on the dark matter and dark energy interactions from weak lensing bispectrum tomography

    Energy Technology Data Exchange (ETDEWEB)

    An, Rui [School of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai 200240 (China); Feng, Chang [Department of Physics and Astronomy, University of California, Irvine, CA 92697 (United States); Wang, Bin, E-mail: an_rui@sjtu.edu.cn, E-mail: chang.feng@uci.edu, E-mail: wang_b@sjtu.edu.cn [Center for Gravitation and Cosmology, College of Physical Science and Technology, Yangzhou University, Yangzhou 225009 (China)

    2017-10-01

    We estimate uncertainties of cosmological parameters for phenomenological interacting dark energy models using weak lensing convergence power spectrum and bispectrum. We focus on the bispectrum tomography and examine how well the weak lensing bispectrum with tomography can constrain the interactions between dark sectors, as well as other cosmological parameters. Employing the Fisher matrix analysis, we forecast parameter uncertainties derived from weak lensing bispectra with a two-bin tomography and place upper bounds on strength of the interactions between the dark sectors. The cosmic shear will be measured from upcoming weak lensing surveys with high sensitivity, thus it enables us to use the higher order correlation functions of weak lensing to constrain the interaction between dark sectors and will potentially provide more stringent results with other observations combined.

  19. The Lenses Structure and Dynamics Survey: luminous and dark matter in high redshift early-type galaxies

    NARCIS (Netherlands)

    Treu, T.; Koopmans, L.

    2003-01-01

    I will present the latest results from the Lenses Structure and Dynamics (LSD) Survey. Using ESI on the Keck Telescope, we have measured spatially resolved stellar kinematics for a sample of 11 early-type galaxies (E/S0s) in the range z=0.1-1, selected as gravitational lenses. By combining lensing

  20. [OPTIC PROPERTIES OF MYOPIC CORRECTION BY ORTHOKERATOLOGY CONTACT LENSES (A CASE REPORT)].

    Science.gov (United States)

    Mýlková, M; Pluháček, F

    2017-01-01

    Orthokeratology lenses present a special type of hard contact lenses, which is used especially for myopic correction. The lenses are applied during the night, when thanks to their special shape cause temporally (reversible) change of the cornea shape. During the day, there is not necessary to wear any other refractive correction. Due to the wearing regimen, there is, comparing to the classical contact lenses, higher risk of health complications. For their safe use, it is necessary to pay attention to the application of lenses of adequate parameters, follow up the care and hygiene precautions, regular controls and early treatment of possible problems. The application of contact lenses should be done by experienced and well-educated expert in contact lens fitting. In the Czech Republic, this method is practically not used. The aim of the case report was to follow up the course of concrete application of orthokeratology lenses for myopic correction from the optic (refractive) point of view, and to evaluate the optic changes in the system of the eye. In the followed up subject, there were measured subjective changes in refraction, visual acuity, corneal curvature, corneal and whole eye aberrations, and corneal thickness during the period of one month after the beginning of lens application (initial phase). The same parameters were followed-up during one-month period since the termination of lens wearing for three months (second phase). The subject was a woman, 24 years old, myopic, with the refractive error in the right eye -3.0 spherical diopters and astigmatism of -0.25 cylinder in the axis 90°, and in the left eye -2.75 spherical diopters without astigmatism; without ophthalmologic or systemic diseases. The full correction of the refractive error after the orthokeratology lenses application occurred approximately after four nights (wearing the lenses overnight). Concurrently, during the day, slight recurrence to original values was evident. With the decreased

  1. The protective effects of l-carnitine and vitamin e in rat lenses in irradiation-induced oxidative injury

    International Nuclear Information System (INIS)

    Taysi, S.; Okumus, S.; Ezirmik, S.; Uzun, N.; Yilmaz, A.; Akyuz, M.; Tekelioglu, U.; Dirier, A.; Al, B.

    2011-01-01

    Objectives. The aim of this study was to evaluate the antioxidant role of L-carnitine (LC) and vitamin E against radiation-induced cataracts in rat lenses after total cranial irradiation with a single 5 Gray (Gy) dose of gamma irradiation. Material and Methods. Thirty two Sprague-Dawley rats were used for the experiment. The control group did not receive LC and vitamin E or irradiation but received both 0.1 ml physiological saline intraperitoneally and sham irradiation. The irradiation (IR) group received 5 Gy gamma irradiation to the total cranium as a single dose plus 0.1 ml physiological saline intraperitoneally. The IR plus vitamin E group received irradiation to total cranium plus 10 mg/kg/day vitamin E intraperitoneally. The IR plus LC group received irradiation to total cranium plus 100 mg/kg/day LC intraperitoneally. Biochemical parameters measured in murine lenses were carried out using spectrophotometric techniques. Results. Total superoxide scavenger activity (TSSA), non-enzymatic superoxide scavenger activity (NSSA), glutathione-S-transferase (GST) and glutathione reductase (GRD) activities, significantly increased in the control, IR plus vitamin E and LC plus IR groups when compared with the IR only group. Lens TSSA and NSSA activities in the control group were significantly increased compared to that of the IR only group, but decreased compared to those of the IR plus vitamin E and IR plus LC groups. Lens xanthine oxidase (XO) activity in the IR group significantly increased compared to those of other groups. Conclusions. Results show that LC and vitamin E prevented oxidative stress by scavenging free radicals generated by ionizing radiation in rat lenses. (authors)

  2. To calculation of electron-optical characteristics of crossed lenses

    International Nuclear Information System (INIS)

    Afanas'ev, V.P.; Gritsyuk, N.P.; Lachashvili, R.A.; Yavor, S.Ya.

    1979-01-01

    Two approaches are used for theoretical study of crossed lenses (CL), which are formed by plates with slits turned by 90 deg: 1) aberration determination according to axial determination of potential and 2) trajectory analysis of CL. While studying CL of definite configuration it is necessary to take into account aberrations of the highest order. The following conclusions are drawn: the classical method is applied for fast determination of the main characteristics, of CL by means of average power computers (the ''M-220'' or the ''Minsk-32'' computers); the trajectory analysis should be performed by means of power computer (the BESM-6) when it is necessary to obtain more detailed information of the CL, including the trajectory deflection along the system axis, the dimensions of the point source image taking into account the aberrations of the highest order

  3. Characterization of germanium linear kinoform lenses at Diamond Light Source.

    Science.gov (United States)

    Alianelli, L; Sawhney, K J S; Tiwari, M K; Dolbnya, I P; Stevens, R; Jenkins, D W K; Loader, I M; Wilson, M C; Malik, A

    2009-05-01

    The unprecedented brilliance achieved by third-generation synchrotron sources and the availability of improved optics have opened up new opportunities for the study of materials at the micrometre and nanometre scale. Focusing the synchrotron radiation to smaller and smaller beams is having a huge impact on a wide research area at synchrotrons. The key to the exploitation of the improved sources is the development of novel optics that deliver narrow beams without loss of brilliance and coherence. Several types of synchrotron focusing optics are successfully fabricated using advanced miniaturization techniques. Kinoform refractive lenses are being developed for hard X-ray beamlines, and the first test results at Diamond are discussed in this paper.

  4. Laboratory analyses of two explanted hydrophobic acrylic intraocular lenses

    Directory of Open Access Journals (Sweden)

    Yunhai Dai

    2014-01-01

    Full Text Available Two three-piece hydrophobic acrylic intraocular lenses (IOLs were explanted from two patients at 7 and 9 years, respectively, after implantation, because of poor fundus visualisation and/or a clinically significant decrease in visual acuity related to their opacified IOLs. In addition to light microscopy, scanning electron microscopy and energy dispersive X-ray spectroscopy, confocal laser scanning microscopy was used for the first time to observe the explanted IOLs. The clinical aspect seemed to correspond to the phenomenon of surface light scattering, while laboratory analyses showed dense glistenings in the central layer of the IOL optic, which had no change next to the surface. Further studies on these phenomena are needed.

  5. Cosmological Constraints from Galaxy Clustering and Weak Lensing

    Science.gov (United States)

    Troxel, Michael; DES Collaboration

    2018-01-01

    The Dark Energy Survey (DES) is a five-year, 5000 sq. deg. observing program using the Dark Energy Camera on the 4m Blanco telescope at CTIO. I will describe the cosmological analysis of large-scale structure in the Universe using 1321 sq. deg. of data taken in the first year of DES operations. The analysis combines unprecedented measurements of weak gravitational lensing and the clustering of galaxies over the redshift range 0.2 to 1.3 to derive the most precise such cosmological constraints to date. These DES results from the low-redshift Universe are consistent with those from the cosmic microwave background (CMB) and support the standard cosmological model, LCDM. In the coming years, DES will produce significantly tighter constraints on cosmology through similar and additional analyses using observations over more than three times the sky-area and more than twice the integrated exposure time per object as these results.

  6. Membrane-based aberration-corrected tunable micro-lenses

    Science.gov (United States)

    Waibel, Philipp; Ermantraut, Eugen; Mader, Daniel; Zappe, Hans; Seifert, Andreas

    2010-05-01

    We present measurements and simulations of membrane-based micro-lens stacks, tunable in focal length in the range of 10mm to 50mm without chromatic aberration. The pressure-actuated, liquid-filled, membrane-based micro-lenses are fabricated by an all-silicone molding approach and consist of three chambers separated by two highly flexible silicone-membranes. Based on the idea of the classical achromatic Fraunhofer doublet, two different liquids with suitable optical properties are used. Pressure-dependent surface topologies are measured by profilometry for determining the correlation between refraction and applied pressure. The profiles are fit to polynomials; the coefficients of the polynomials are pressure-dependent and fit to empirically determined functions which are then used as an input for optical ray-tracing. Using this approach, the focal length is tunable while compensating for chromatic aberration by suitably applied pressures.

  7. Glimpse: Sparsity based weak lensing mass-mapping tool

    Science.gov (United States)

    Lanusse, F.; Starck, J.-L.; Leonard, A.; Pires, S.

    2018-02-01

    Glimpse, also known as Glimpse2D, is a weak lensing mass-mapping tool that relies on a robust sparsity-based regularization scheme to recover high resolution convergence from either gravitational shear alone or from a combination of shear and flexion. Including flexion allows the supplementation of the shear on small scales in order to increase the sensitivity to substructures and the overall resolution of the convergence map. To preserve all available small scale information, Glimpse avoids any binning of the irregularly sampled input shear and flexion fields and treats the mass-mapping problem as a general ill-posed inverse problem, regularized using a multi-scale wavelet sparsity prior. The resulting algorithm incorporates redshift, reduced shear, and reduced flexion measurements for individual galaxies and is made highly efficient by the use of fast Fourier estimators.

  8. Dark matter halos: Consistency between rotational curves and gravitational lenses

    International Nuclear Information System (INIS)

    Gonzalez-Morales, Alma X; Nunez, Dario

    2010-01-01

    The main point of this work is to emphasize the fact that the estimation of the mass content of a dark matter halo must be done in a consistent way with the nature of the dark matter. In general relativity, depending on how dark matter nature is modelled, different expressions arise for the computation of the mass and the deflection of light. Here we present the comparison of the mass estimated by assuming two different dark matter models, the first one in which dark matter is modelled by a perfect fluid and the second in which it is modelled by a scalar field, but assuming they both reproduce the same rotation curve and discuss the consequences for the lensing observations.

  9. Lensing-induced morphology changes in CMB temperature maps in modified gravity theories

    Energy Technology Data Exchange (ETDEWEB)

    Munshi, D.; Coles, P. [Astronomy Centre, School of Mathematical and Physical Sciences, University of Sussex, Brighton BN1 9QH (United Kingdom); Hu, B. [Institut de Ciències del Cosmos (ICCUB), Universitat de Barcelona (IEEC-UB), Martí i Franquès 1, E08028 Barcelona (Spain); Matsubara, T. [Kobayashi-Maskawa Institute, Nagoya University, Chikusa, Nagoya 464-8602 (Japan); Heavens, A., E-mail: D.Munshi@sussex.ac.uk, E-mail: binhu@icc.ub.edu, E-mail: taka@kmi.nagoya-u.ac.jp, E-mail: P.Coles@sussex.ac.uk, E-mail: a.heavens@imperial.ac.uk [Imperial Centre for Inference and Cosmology, Blackett Laboratory, Prince Consort Road, London SW7 2AZ (United Kingdom)

    2016-04-01

    Lensing of the Cosmic Microwave Background (CMB) changes the morphology of pattern of temperature fluctuations, so topological descriptors such as Minkowski Functionals can probe the gravity model responsible for the lensing. We show how the recently introduced two-to-two and three-to-one kurt-spectra (and their associated correlation functions), which depend on the power spectrum of the lensing potential, can be used to probe modified gravity theories such as f ( R ) theories of gravity and quintessence models. We also investigate models based on effective field theory, which include the constant-Ω model, and low-energy Hořava theories. Estimates of the cumulative signal-to-noise for detection of lensing-induced morphology changes, reaches O(10{sup 3}) for the future planned CMB polarization mission COrE{sup +}. Assuming foreground removal is possible to ℓ{sub max}=3000, we show that many modified gravity theories can be rejected with a high level of significance, making this technique comparable in power to galaxy weak lensing or redshift surveys. These topological estimators are also useful in distinguishing lensing from other scattering secondaries at the level of the four-point function or trispectrum. Examples include the kinetic Sunyaev-Zel'dovich (kSZ) effect which shares, with lensing, a lack of spectral distortion. We also discuss the complication of foreground contamination from unsubtracted point sources.

  10. Noise Estimates for Measurements of Weak Lensing from the Lyman-alpha Forest

    Science.gov (United States)

    Metcalf, R. Benton; Croft, Rupert A. C.; Romeo, Alessandro

    2018-03-01

    Lensing changes the apparent separation between pixels in the Lyman-α forest of separate quasars or high redshift objects by changing their observed positions on the sky. This changes the implied correlations in the absorption and in particular makes the Lyman-α forest correlation function, or power spectrum, locally anisotropic in the plane of the sky. We have proposed a method for measuring weak lensing using this effect. Here we estimate the noise expected in weak lensing maps and power spectra for different sets of observational parameters. We find that surveys of the size and quality of the ones being done today and ones planned for the future will be able to measure the lensing power spectrum at a source redshift of z ≃ 2.5 with high precision and even be able to image the distribution of foreground matter with high fidelity on degree scales. For example, we predict that Lyman-α forest lensing measurements from the DESI and WEAVE surveys should yield the mass fluctuation amplitude with a statistical error of ˜3%, eBOSS ˜6%. and the proposed MSE survey less than 1%. By dividing the redshift range into multiple bins some tomographic lensing information should be accessible as well. This would allow for cosmological lensing measurements at higher redshift than are accessible with galaxy shear surveys and correspondingly better constraints on the evolution of dark energy at relatively early times.

  11. Spectral transmittance of UV-blocking soft contact lenses: a comparative study.

    Science.gov (United States)

    Rahmani, Saeed; Mohammadi Nia, Mohadeseh; Akbarzadeh Baghban, Alireza; Nazari, Mohammad Reza; Ghassemi-Broumand, Mohammad

    2014-12-01

    Three major parts of sunlight consist of visible, ultraviolet and infrared radiation. Exposure to ultraviolet radiation (UVR) can result in a spectrum of skin and ocular diseases. UV-blocking contact lenses help provide protection against harmful UV radiation. We studied the ultraviolet and visible light rays transmission in some soft UV-blocking contact lenses. Four available tinted soft lenses (Acuvue Moist, Zeiss CONTACT Day 30 Air spheric, Pretty Eyes and Sauflon 56 UV) have been evaluated for UV and visible transmission. One-way ANOVA testing was performed to establish is there a statistically significant difference between the UV regions and visible spectra means for the contact lenses (α=0.05). Pretty Eyes, Zeiss CONTACT, Acuvue Moist and Sauflon 56 UV showed UV-B transmittance value of 0.65%, 10.69%, 1.22%, and 5.78%, respectively. Pretty Eyes and Acuvue Moist had UV-A transmittance values of 32% and 34%, Sauflon 56 UV and Zeiss CONTACT had transmittance values of 48% and 43%, respectively. All of the studied lenses transmitted at least 94.6% on the visible spectrum. The results of the one-way ANOVA statistical analysis show that a statistically significant difference exists within the group of contact lenses tested for the visible (pUV-B (pUV-A (pUV-blocking property and also visible transmission between other tested contact lenses in this study. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  12. Ocular Drug Delivery through pHEMA-Hydrogel Contact Lenses Co-Loaded with Lipophilic Vitamins

    Science.gov (United States)

    Lee, Dasom; Cho, Seungkwon; Park, Hwa Sung; Kwon, Inchan

    2016-09-01

    Ocular drug delivery through hydrogel contact lenses has great potential for the treatment of ocular diseases. Previous studies showed that the loading of lipophilic vitamin E to silicone-hydrogel contact lenses was beneficial in ocular drug delivery. We hypothesized that vitamin E loading to another type of popular hydrogel contact lenses, pHEMA-hydrogel contact lenses, improves ocular drug delivery by increasing the drug loading or the duration of drug release. Loading of vitamin E to pHEMA-hydrogel contact lenses significantly increased the loading of a hydrophilic drug surrogate (Alexa Fluor 488 dye) and two hydrophilic glaucoma drugs (timolol and brimonidine) to the lenses by 37.5%, 19.1%, and 18.7%, respectively. However, the release duration time was not significantly altered. Next, we hypothesized that the lipophilic nature of vitamin E attributes to the enhanced drug loading. Therefore, we investigated the effects of co-loading of another lipophilic vitamin, vitamin A, on drug surrogate delivery. We found out that vitamin A loading also increased the loading of the drug surrogate to pHEMA-hydrogel contact lenses by 30.3%. Similar to vitamin E loading, vitamin A loading did not significantly alter the release duration time of the drug or drug surrogate.

  13. Microbiologic study of soft contact lenses after laser subepithelial keratectomy for myopia.

    Science.gov (United States)

    Hondur, Ahmet; Bilgihan, Kamil; Cirak, Meltem Yalinay; Dogan, Ozgur; Erdinc, Alper; Hasanreisoglu, Berati

    2008-01-01

    To evaluate the extent and agents of bacterial contamination of bandage disposable soft contact lenses after laser subepithelial keratectomy (LASEK) and to correlate the findings with clinical data. Disposable soft contact lenses were collected from 52 eyes of 26 consecutive patients treated with LASEK for myopia. The patients were treated with a fixed combination of tobramycin and diclofenac until epithelial closure. The lenses were removed on the fourth or fifth postoperative day with sterile forceps and immediately placed in sterile tubes containing culture media brain-heart infusion broth. The lenses were evaluated for microbial colonization. Of the 52 contact lenses analyzed, six (11.5%) had positive cultures. However, no clinical finding of infection was noted. Isolated microorganisms were coagulase-negative staphylococci (two lenses), Stenotrophomonas maltophilia (two lenses), Acinetobacter species (one lens), and Aeromonas hydrophila (one lens). Except for one case, the microorganisms were sensitive to the administered antibiotic. The risk of infectious keratitis after LASEK seems to be low. Except for staphylococci, the isolated microorganisms have not been previously reported to colonize the ocular surface or cause keratitis after refractive surgery. These findings may suggest a changing trend of potentially infectious agents after surface ablation.

  14. Constraining gravity at the largest scales through CMB lensing and galaxy velocities

    Science.gov (United States)

    Pullen, Anthony R.; Alam, Shadab; He, Siyu; Ho, Shirley

    2016-08-01

    We demonstrate a new method to constrain gravity on the largest cosmological scales by combining measurements of cosmic microwave background (CMB) lensing and the galaxy velocity field. EG is a statistic, constructed from a gravitational lensing tracer and a measure of velocities such as redshift-space distortions (RSD), that can discriminate between gravity models while being independent of clustering bias and σ8. While traditionally, the lensing field for EG has been probed through galaxy lensing, CMB lensing has been proposed as a more robust tracer of the lensing field for EG at higher redshifts while avoiding intrinsic alignments. We perform the largest-scale measurement of EG ever, up to 150 Mpc h-1, by cross-correlating the Planck CMB lensing map with the Sloan Digital Sky Survey III (SDSS-III) CMASS galaxy sample and combining this with our measurement of the CMASS auto-power spectrum and the RSD parameter β. We report EG(z = 0.57) = 0.243 ± 0.060 (stat) ± 0.013 (sys), a measurement in tension with the general relativity (GR) prediction at a level of 2.6σ. Note that our EG measurement deviates from GR only at scales greater than 80 Mpc h-1, scales which have not been probed by previous EG tests. Upcoming surveys, which will provide an order-of-magnitude reduction in statistical errors, can significantly constrain alternative gravity models when combined with better control of systematics.

  15. Shallow rainwater lenses in deltaic areas with saline seepage

    Directory of Open Access Journals (Sweden)

    P. G. B. de Louw

    2011-12-01

    Full Text Available In deltaic areas with saline seepage, freshwater availability is often limited to shallow rainwater lenses lying on top of saline groundwater. Here we describe the characteristics and spatial variability of such lenses in areas with saline seepage and the mechanisms that control their occurrence and size. Our findings are based on different types of field measurements and detailed numerical groundwater models applied in the south-western delta of the Netherlands. By combining the applied techniques we could extrapolate measurements at point scale (groundwater sampling, temperature and electrical soil conductivity (TEC-probe measurements, electrical cone penetration tests (ECPT to field scale (continuous vertical electrical soundings (CVES, electromagnetic survey with EM31, and even to regional scale using helicopter-borne electromagnetic measurements (HEM. The measurements show a gradual mixing zone between infiltrating fresh rainwater and upward flowing saline groundwater. The mixing zone is best characterized by the depth of the centre of the mixing zone Dmix, where the salinity is half that of seepage water, and the bottom of the mixing zone Bmix, with a salinity equal to that of the seepage water (Cl-conc. 10 to 16 g l−1. Dmix is found at very shallow depth in the confining top layer, on average at 1.7 m below ground level (b.g.l., while Bmix lies about 2.5 m b.g.l. The model results show that the constantly alternating upward and downward flow at low velocities in the confining layer is the main mechanism of mixing between rainwater and saline seepage and determines the position and extent of the mixing zone (Dmix and Bmix. Recharge, seepage flux, and drainage depth are the controlling factors.

  16. Fluid-filled scleral contact lenses in vernal keratoconjunctivitis.

    Science.gov (United States)

    Rathi, Varsha M; Sudharman Mandathara, Preeji; Vaddavalli, Pravin Krishna; Dumpati, Srikanth; Chakrabarti, Tamal; Sangwan, Virender S

    2012-05-01

    The purpose of this study is to report on the use of fluid-filled scleral contact lenses (F-ScCL) in patients with vernal keratoconjunctivitis (VKC). We retrospectively reviewed charts of four patients who had worn F-ScCL (PROSE, Boston Foundation for Sight, Needham Heights, MA) from July 2006 for VKC with two associated conditions; keratoconus and limbal stem-cell deficiency (LSCD). Any previous refractive correction or complications were noted. The main goal of fitting F-ScCL was to improve visual acuity in keratoconus and to improve the ocular microenvironment in LSCD. Visual acuity before and during lens wear and the average wearing time in hours per day was noted. Four patients (7 eyes) with VKC wore F-ScCL for associated keratoconus (n=5 eyes), LSCD (n=2 eyes). The mean age of the patients was 17. 5 years. The LogMAR visual acuity was 0.4 and 0.18 before and during lens wear, respectively, at a mean follow-up of 14.8 months. The average lens wear was 8.30 hrs per day. Two patients developed acute hydrops at 2 and 12 months of lens wear and underwent descematopexy. Visual acuity with F-ScCL reduced by more than two lines because of the scar of healed hydrops. Of the 3 patients with keratoconus, 1 patient had used a piggy back lens system for 2.5 years before F-ScCL wear, and 2 patients had failed with rigid gas-permeable lens trial lenses. With coexisting keratoconus and VKC, F-ScCL improves vision and helps to maintain the health of the ocular surface.

  17. Scleral contact lenses in the management of pellucid marginal degeneration.

    Science.gov (United States)

    Rathi, Varsha M; Dumpati, Srikanth; Mandathara, Preeji S; Taneja, Mukesh M; Sangwan, Virender S

    2016-06-01

    To assess visual improvement with scleral lenses (PROSE, prosthetic replacement of the ocular surface ecosystem, Boston Foundation for Sightight, USA) in patients with Pellucid marginal degeneration (PMD). This is a single-center, retrospective case-series involving patients with clinical PMD who underwent scleral lens-PROSE trial for improvement of visual acuity, from January 2009 to December 2012 at a tertiary center in India. Scleral lenses with different front surface eccentricities (FSE) were tried for improvement of visual acuity. Snellen visual acuity before and with PROSE wear was noted. Complications with PROSE wear to follow-up were noted. PROSE was dispensed to 12 patients (20 eyes) out of 19 patients having PMD. Location of PMD was inferior in fourteen and superior in two eyes. Four eyes had co-existing keratoconus. Nine were males and three were females. The indications for scleral lens were lens popping-out, failure of piggy-back contact lens and RGP failure. LogMAR Visual acuity improved significantly from 0.45±0.31 pre-PROSE to 0.05±0.08 post-PROSE (p=0.0001). The FSE ordered was 0.6 in 17 eyes, 0.3 in one eye and 0.8 in two eyes. Three patients had hydrops over follow-up; two patients underwent keratoplasty and one was managed conservatively with steroids and hyperosmotic agents. Seven patients did not order PROSE: reasons were - no perceived improvement in visual acuity (n=2), wanted to decide (n=2), continued glasses (n=1) and continued RGP contact lens (n=1). One patient had difficulty with self lens insertion. PROSE improves visual acuity in PMD; three patients developed hydrops over follow-up. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  18. Constraining dark sector perturbations II: ISW and CMB lensing tomography

    Science.gov (United States)

    Soergel, B.; Giannantonio, T.; Weller, J.; Battye, R. A.

    2015-02-01

    Any Dark Energy (DE) or Modified Gravity (MG) model that deviates from a cosmological constant requires a consistent treatment of its perturbations, which can be described in terms of an effective entropy perturbation and an anisotropic stress. We have considered a recently proposed generic parameterisation of DE/MG perturbations and compared it to data from the Planck satellite and six galaxy catalogues, including temperature-galaxy (Tg), CMB lensing-galaxy (varphi g) and galaxy-galaxy (gg) correlations. Combining these observables of structure formation with tests of the background expansion allows us to investigate the properties of DE/MG both at the background and the perturbative level. Our constraints on DE/MG are mostly in agreement with the cosmological constant paradigm, while we also find that the constraint on the equation of state w (assumed to be constant) depends on the model assumed for the perturbation evolution. We obtain w=-0.92+0.20-0.16 (95% CL; CMB+gg+Tg) in the entropy perturbation scenario; in the anisotropic stress case the result is w=-0.86+0.17-0.16. Including the lensing correlations shifts the results towards higher values of w. If we include a prior on the expansion history from recent Baryon Acoustic Oscillations (BAO) measurements, we find that the constraints tighten closely around w=-1, making it impossible to measure any DE/MG perturbation evolution parameters. If, however, upcoming observations from surveys like DES, Euclid or LSST show indications for a deviation from a cosmological constant, our formalism will be a useful tool towards model selection in the dark sector.

  19. UV solid state laser ablation of intraocular lenses

    Science.gov (United States)

    Apostolopoulos, A.; Lagiou, D. P.; Evangelatos, Ch.; Spyratou, E.; Bacharis, C.; Makropoulou, M.; Serafetinides, A. A.

    2013-06-01

    Commercially available intraocular lenses (IOLs) are manufactured from silicone and acrylic, both rigid (e.g. PMMA) and foldable (hydrophobic or hydrophilic acrylic biomaterials), behaving different mechanical and optical properties. Recently, the use of apodizing technology to design new diffractive-refractive multifocals improved the refractive outcome of these intraocular lenses, providing good distant and near vision. There is also a major ongoing effort to refine laser refractive surgery to correct other defects besides conventional refractive errors. Using phakic IOLs to treat high myopia potentially provides better predictability and optical quality than corneal-based refractive surgery. The aim of this work was to investigate the effect of laser ablation on IOL surface shaping, by drilling circular arrays of holes, with a homemade motorized rotation stage, and scattered holes on the polymer surface. In material science, the most popular lasers used for polymer machining are the UV lasers, and, therefore, we tried in this work the 3rd and the 5th harmonic of a Q-switched Nd:YAG laser (λ=355 nm and λ=213 nm respectively). The morphology of the ablated IOL surface was examined with a scanning electron microscope (SEM, Fei - Innova Nanoscope) at various laser parameters. Quantitative measurements were performed with a contact profilometer (Dektak-150), in which a mechanical stylus scanned across the surface of gold-coated IOLs (after SEM imaging) to measure variations in surface height and, finally, the ablation rates were also mathematically simulated for depicting the possible laser ablation mechanism(s). The experimental results and the theoretical modelling of UV laser interaction with polymeric IOLs are discussed in relation with the physical (optical, mechanical and thermal) properties of the material, in addition to laser radiation parameters (laser energy fluence, number of pulses). The qualitative aspects of laser ablation at λ=213 nm reveal a

  20. Power spectrum of dark matter substructure in strong gravitational lenses

    Science.gov (United States)

    Diaz Rivero, Ana; Cyr-Racine, Francis-Yan; Dvorkin, Cora

    2018-01-01

    Studying the smallest self-bound dark matter structure in our Universe can yield important clues about the fundamental particle nature of dark matter. Galaxy-scale strong gravitational lensing provides a unique way to detect and characterize dark matter substructures at cosmological distances from the Milky Way. Within the cold dark matter (CDM) paradigm, the number of low-mass subhalos within lens galaxies is expected to be large, implying that their contribution to the lensing convergence field is approximately Gaussian and could thus be described by their power spectrum. We develop here a general formalism to compute from first principles the substructure convergence power spectrum for different populations of dark matter subhalos. As an example, we apply our framework to two distinct subhalo populations: a truncated Navarro-Frenk-White subhalo population motivated by standard CDM, and a truncated cored subhalo population motivated by self-interacting dark matter (SIDM). We study in detail how the subhalo abundance, mass function, internal density profile, and concentration affect the amplitude and shape of the substructure power spectrum. We determine that the power spectrum is mostly sensitive to a specific combination of the subhalo abundance and moments of the mass function, as well as to the average tidal truncation scale of the largest subhalos included in the analysis. Interestingly, we show that the asymptotic slope of the substructure power spectrum at large wave number reflects the internal density profile of the subhalos. In particular, the SIDM power spectrum exhibits a characteristic steepening at large wave number absent in the CDM power spectrum, opening the possibility of using this observable, if at all measurable, to discern between these two scenarios.

  1. Ballistic impact resistance of selected organic ophthalmic lenses.

    Science.gov (United States)

    Chou, B Ralph; Yuen, Gloria S-C; Dain, Stephen J

    2011-11-01

    The aim was to assess the impact resistance of coated and uncoated mid-index spectacle lens materials using the ballistic impact test. Nominally plano lenses of each material in three thicknesses were obtained. The lenses were flat edged to a 50 mm diameter. Each lens was impacted by a 6.35 mm steel ball. Impact velocities were selected using the Zippy Estimation by Sequential Testing protocol to determine the threshold fracture impact velocity. Threshold fracture impact velocity generally increased with thickness; however, there was a wide variation in performance among the various lens materials at each thickness. In all but two instances, the differences in impact velocity at each thickness of lens material were significant. Comparison of the data for CR39 and Hoya Phoenix with the results of earlier studies showed that the lens mounting is a significant factor. The fracture velocities found in the present study were significantly lower than the fracture velocities found when the lens edge is restrained in the mounting. A scratch resistant coating reduced the impact resistance of CR39. The effect of the antireflection coating on the fracture velocity depended on the nature of the base scratch-resistant coating. Mid-index lens materials of the same thickness show widely varying levels of impact resistance under the ballistic test. Impact resistance increases non-linearly with centre thickness. The lens mounting might affect the results of the ballistic impact test. The presence of 'cushion coatings' might enhance impact resistance. © 2011 The Authors. Clinical and Experimental Optometry © 2011 Optometrists Association Australia.

  2. Changes in UV-visible transmittance of silicone-hydrogel contact lenses induced by wear.

    Science.gov (United States)

    Lira, Madalena; Dos Santos Castanheira, Elisabete M; Santos, Lívia; Azeredo, Joana; Yebra-Pimentel, Eva; Real Oliveira, M Elisabete C D

    2009-04-01

    To evaluate the influence of wear of silicone-hydrogel contact lenses on lens ultraviolet and visible spectrum transmittance by studying several contact lenses before and after wear. To investigate the ability of contact lenses to maintain their transmittance characteristics, we measured 104 different contact lenses in the ultraviolet (UV) and visible range from 200 to 700 nm, with a Shimadzu UV3101-PC UV-vis-NIR spectrophotometer equipped with an integrating sphere. The lenses used in this study were Acuvue Advance (Johnson & Johnson Vision Care, Inc.), Air Optix Night & Day (CIBA Vision), Air Optix (CIBA Vision), and PureVision (Bausch & Lomb). A conventional hydrogel contact lens was also tested, Acuvue (Johnson & Johnson Vision Care Inc.). Our study indicates that lenses that do not have UV absorbers incorporated into the polymer transmitted most of the UV radiation (UVR) before and after wear. The results of the statistical analysis show that for the UVC portion of the spectrum significant difference exists within the measurements obtained before and after wear for all the lenses, with the exception of PureVision. Acuvue Advance is the only material in which significant transmittance differences were observed in the visible spectral range. Transmittance is modified after contact lenses wear, probably due to the formation of biofilms on the contact lens surface, being more noticeable in the UVR region of the spectrum (200-400 nm). Silicone-hydrogel and conventional hydrogel contact lens materials that provide UVR protection (UV-blocker) maintain this property even after being worn. The changes observed in the visible spectrum seem not to have any implications in visual performance of silicone-hydrogel contact lenses.

  3. Oxygen permeability of soft contact lenses in different pH, osmolality and buffering solution

    Directory of Open Access Journals (Sweden)

    Se Eun Lee

    2015-10-01

    Full Text Available AIM: To determine the effect of pH, osmolality, and buffering system on the oxygen permeability (Dk of soft contact lenses.METHODS: Two hydrogel lenses (nelfilcon A and etafilcon A and 2 silicone hydrogel lenses (lotrafilcon A and balafilcon A were used in the study. These lenses were incubated in phosphate-buffered saline (PBS and borate-buffered saline (BBS solutions adjusted by 0.8 pH increments to a pH in the range of 5.8-9.0 or in hypotonic (280 mOsmol/kg, isotonic (310 mOsmol/kg and hypertonic (380 mOsmol/kg PBS solutions. Polarographic method was used for measuring the Dk and lenses were stacked as 4 layers to correct the boundary effect.RESULTS: Dk values of all contact lenses measured in BBS solutions were more stable than those in PBS solutions. Especially the etafilcon A lens showed a relative big change compared with other types of contact lenses at the same conditions. When the osmolality of PBS solution increased from hypotonic to hypertonic, Dk of all contact lenses decreased. Variations in Dk existed depending on lens materials, etafilcon A lens was the most affected and nelfilcon A was the least affected by osmolality.CONCLUSION:From the result obtained, it is revealed that Dk of contact lenses is changed by the pH, osmolality, and buffering condition of tear. Thus, Dk of contact lens can be varied by the lens wearers'' physiological and/or pathological conditions.

  4. Comparison of Occurrence of Free Volumes for Rigid Gas Permeable and Soft Contact Lenses.

    Science.gov (United States)

    Filipecka, Katarzyna; Budaj, Mariusz; Miskowiak, Bogdan; Makowska-Janusik, Małgorzata; Filipecki, Jacek

    2015-01-01

    The polymeric materials: hydrogel, silicone--hydrogel and methacrylic acid are used in ophthalmology for the manufacture of contact lenses. It is important to research the structure of these materials, mainly the prevalence of free volumes. The study has been conducted in order to comparison the presence of free volume gaps in the structure of the polymer soft contact lenses: Etafilcon A (hydrogel), Narafilcon A (silicone-hydrogel) and the polymer rigid gas permeable (RGP) contact lens (Fluor-Silicon-Methacrylat-Copolymer). In addition, to demonstrate differences in the occurrence of free volumes between types of represented contact lenses. Three types of polymer contact lenses were used as materials: Etafilcon A, Narafilcon A and Fluor-Silicon-Methacrylat-Copolymer. The study was done by means of positron annihilation lifetime spectroscopy (PALS). As a result of the performed measurements, a graphical curve resulted which describes the relationship between the number of the annihilation acts in the time function. Significant changes were observed in the ortho-positronium long life component τ3 and their intensities between the examined polymer contact lenses. The conducted study using the Tao-Eldrup model indicates the presence of free volume holes in all research materials. There is a clear difference in the free volume sizes and their fractions between measured contact lenses are connected with oxygen permeability in these lenses. The results lead to the following connection: contact lenses of higher oxygen permeability coefficients and a water content of less, have more and larger free volumes than contact lenses of less oxygen permeability coefficient.

  5. Clinical outcomes of scleral Misa lenses for visual rehabilitation in patients with pellucid marginal degeneration.

    Science.gov (United States)

    Asena, Leyla; Altınörs, Dilek Dursun

    2016-12-01

    To report the clinical outcomes of scleral Misa ® lenses (Microlens Contactlens Technolgy, Arnhem, Netherlands) for visual rehabilitation in patients with pellucid marginal degeneration (PMD). In this prospective interventional case series, 24 eyes of 12 PMD patients were fitted with scleral Misa ® lenses. Patients were followed regularly for continuous daily wearing time (CDWT), contact lens handling issues, visual acuity, and any subjective or objective contact lens related complications. The mean patient age was 35.0±13.8 years (range, 23-47 years). The average length of follow-up was 14.1±3.7 months (range, 8.5-18 months). All eyes were fit with mini Misa ® scleral lenses with a diameter of 16.5 or 17mm. The mean Snellen best-corrected visual acuity (BCVA) before scleral lenses with spectacle correction was 0.42±0.15 (range, 0.2-0.6). With scleral lenses, mean BCVA was 0.75±0.15 (range, 0.5-0.9), (p=0.003) with a mean gain of 3.3 lines of BCVA. More than half (16 eyes, 67%) reported wearing their scleral lenses for 8h or more on a daily basis. Three patients (6 eyes, 25%) abandoned scleral lens wear. Patients who abandoned the scleral lens wear tended to have a better spectacle corrected visual acuity and less gain of lines. Scleral lenses can be used succesfully in patients with PMD who are intolerant to other types of contact lenses. Patients who have a low spectacle BCVA and a higher gain of visual acuity with scleral lenses are good candidates for scleral lens use. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  6. Efficacy of detergent and water versus bleach for disinfection of direct contact ophthalmic lenses.

    Science.gov (United States)

    Abbey, Ashkan M; Gregori, Ninel Z; Surapaneni, Krishna; Miller, Darlene

    2014-06-01

    Although manufacturers recommend cleaning ophthalmic lenses with detergent and water and then with a specific disinfectant, disinfectants are rarely used in ophthalmic practices. The aim of this pilot study was to evaluate the efficacy of detergent and water versus that of bleach, a recommended disinfectant, to eliminate common ocular bacteria and viruses from ophthalmic lenses. Three bacterial strains (Staphylococcus epidermidis, Corynebacterium straitum, and methicillin-resistant Staphylococcus aureus and 2 viral strains (adenovirus and herpes simplex virus [HSV] type-1) were individually inoculated onto 20 gonioscopy and laser lenses. The lenses were washed with detergent and water and then disinfected with 10% bleach. All the lenses were cultured after inoculation, after washing with detergent and water, and after disinfecting with the bleach. Bacterial cultures in thioglycollate broth were observed for 3 weeks, and viral cultures were observed for 2 weeks. The presence of viruses was also detected by multiplex polymerase chain reaction (PCR). All 20 lenses inoculated with S. epidermidis, C. straitum, adenovirus, and HSV-1 showed growth after inoculation but no growth after washing with detergent/water and after disinfecting with the bleach. All lenses showed positive HSV and adenovirus PCR results after inoculation and negative PCR results after washing with detergent/water and after disinfecting with bleach. All methicillin-resistant S. aureus-contaminated lenses showed growth after inoculation and no growth after washing with detergent and water. However, 1 lens showed positive growth after disinfecting with bleach. Cleaning with detergent and water seemed to effectively eliminate bacteria and viruses from the surface of contaminated ophthalmic lenses. Further studies are warranted to design practical disinfection protocols that minimize lens damage.

  7. Observational Evidence for the Effect of Amplification Bias in Gravitational Microlensing Experiments

    Science.gov (United States)

    Han, Cheongho; Jeong, Youngjin; Kim, Ho-Il

    1998-11-01

    Recently Alard, Mao, & Guibert and Alard proposed to detect the shift of a star's image centroid, δx, as a method to identify the lensed source among blended stars. Goldberg & Woźniak actually applied this method to the OGLE-1 database and found that seven of 15 events showed significant centroid shifts of δx >~ 0.2". The amount of centroid shift has been estimated theoretically by Goldberg; however, he treated the problem in general and did not apply it to a particular survey or field and therefore based his estimate on simple toy model luminosity functions (i.e., power laws). In this paper, we construct the expected distribution of δx for Galactic bulge events based on the precise stellar luminosity function observed by Holtzman et al. using the Hubble Space Telescope. Their luminosity function is complete up to MI ~ 9.0 (MV ~ 12), which corresponds to faint M-type stars. In our analysis we find that regular blending cannot produce a large fraction of events with measurable centroid shifts. By contrast, a significant fraction of events would have measurable centroid shifts if they are affected by amplification-bias blending. Therefore, the measurements of large centroid shifts for an important fraction of microlensing events of Goldberg & Woźniak confirm the prediction of Han & Alard that a large fraction of Galactic bulge events are affected by amplification-bias blending.

  8. Detection techniques for the H.E.S.S. II telescope, data modeling of gravitational lensing and emission of blazars in HE-VHE astronomy

    International Nuclear Information System (INIS)

    Barnacka, Anna

    2013-01-01

    with very low photon noise. This allows to use directly Fourier transform methods. A time delay between the two compact images of PKS 1830-211 has been searched for both by the autocorrelation method and a new method: the 'double power spectrum'. The double power spectrum shows a 4.2 σ evidence for a time delay of 27.1±0.6 days, consistent with the results from Lovell et al. (1998) and Wiklind and Combes (2001). The last part of my thesis concentrates on another lensing phenomena called 'femto-lensing'. The search for femto-lensing effects has been used to derive limits on the primordial black holes abundance. The abundance of primordial black holes is currently significantly constrained in a wide range of masses. The weakest limits are established for the small mass objects, where the small intensity of the associated physical phenomenon provides a challenge for current experiments. I have used gamma-ray bursts with known redshifts detected by the FERMI Gamma-ray Burst Monitor (GBM) to search for the femto-lensing effects caused by compact objects. The lack of femto-lensing detection in the GBM data provides new evidence that primordial black holes in the mass range 5 * 10 17 - 10 20 g do not constitute a major fraction of dark matter. My Ph.D. studies have been carried out jointly between the Nicolaus Copernicus Astronomical Center of the Polish Academy of Sciences, in Warsaw in Poland and the IRFU institute of the Commissariat a l'energie atomique et aux energies alternatives(CEA) Saclay in France. (author) [fr

  9. Search for black matter through the detection of gravitational micro-lenses in differential photometry

    International Nuclear Information System (INIS)

    Le Guillou, L.

    2003-09-01

    The nature of dark matter is an open question. The search for gravitational microlensing effects is an interesting tool because this effect is strongly dependent on the mass of objects whether they are luminous or not, however this detection method is only sensitive to compact forms of dark matter (MACHOS - massive astronomical halo compact objects), and as a consequence no-baryonic matter like neutrinos or WIMPS (weakly interacting massive particles) can not be detected this way. In the first chapter the author reviews the plausible candidates to black matter. The use of the microlensing effect as a probe of the galactic halo is presented in the second chapter. The third chapter is dedicated to the series of experiments worldwide that focus on the detection of MACHOS. In the fourth chapter the author shows how the DIA (difference image analysis) method may be promising in the study of gravitational microlensing effects. The main part of this work has been the use of the DIA method to process five-year data set collected by the Eros experiment in the small Magellanic cloud (SMC). The data processing line and the results are presented in the fifth and sixth chapters. The results are consistent with previous results given by Eros and they confirm the disparity of the durations of micro-lenses detected in the large and small Magellanic clouds. (A.C.)

  10. Gravitational lensing: a unique probe of dark matter and dark energy.

    Science.gov (United States)

    Ellis, Richard S

    2010-03-13

    I review the development of gravitational lensing as a powerful tool of the observational cosmologist. After the historic eclipse expedition organized by Arthur Eddington and Frank Dyson, the subject lay observationally dormant for 60 years. However, subsequent progress has been astonishingly rapid, especially in the past decade, so that gravitational lensing now holds the key to unravelling the two most profound mysteries of our Universe-the nature and distribution of dark matter, and the origin of the puzzling cosmic acceleration first identified in the late 1990s. In this non-specialist review, I focus on the unusual history and achievements of gravitational lensing and its future observational prospects.

  11. The Origin of Gravitational Lensing: A Postscript to Einstein's 1936 Science Paper

    Science.gov (United States)

    Renn; Sauer; Stachel

    1997-01-10

    Gravitational lensing, now taken as an important astrophysical consequence of the general theory of relativity, was found even before this theory was formulated but was discarded as a speculative idea without any chance of empirical confirmation. Reconstruction of some of Einstein's research notes dating back to 1912 reveals that he explored the possibility of gravitational lensing 3 years before completing his general theory of relativity. On the basis of preliminary insights into this theory, Einstein had already derived the basic features of the lensing effect. When he finally published the very same results 24 years later, it was only in response to prodding by an amateur scientist.

  12. The detection of a population of submillimeter-bright, strongly lensed galaxies.

    Science.gov (United States)

    Negrello, Mattia; Hopwood, R; De Zotti, G; Cooray, A; Verma, A; Bock, J; Frayer, D T; Gurwell, M A; Omont, A; Neri, R; Dannerbauer, H; Leeuw, L L; Barton, E; Cooke, J; Kim, S; da Cunha, E; Rodighiero, G; Cox, P; Bonfield, D G; Jarvis, M J; Serjeant, S; Ivison, R J; Dye, S; Aretxaga, I; Hughes, D H; Ibar, E; Bertoldi, F; Valtchanov, I; Eales, S; Dunne, L; Driver, S P; Auld, R; Buttiglione, S; Cava, A; Grady, C A; Clements, D L; Dariush, A; Fritz, J; Hill, D; Hornbeck, J B; Kelvin, L; Lagache, G; Lopez-Caniego, M; Gonzalez-Nuevo, J; Maddox, S; Pascale, E; Pohlen, M; Rigby, E E; Robotham, A; Simpson, C; Smith, D J B; Temi, P; Thompson, M A; Woodgate, B E; York, D G; Aguirre, J E; Beelen, A; Blain, A; Baker, A J; Birkinshaw, M; Blundell, R; Bradford, C M; Burgarella, D; Danese, L; Dunlop, J S; Fleuren, S; Glenn, J; Harris, A I; Kamenetzky, J; Lupu, R E; Maddalena, R J; Madore, B F; Maloney, P R; Matsuhara, H; Michaowski, M J; Murphy, E J; Naylor, B J; Nguyen, H; Popescu, C; Rawlings, S; Rigopoulou, D; Scott, D; Scott, K S; Seibert, M; Smail, I; Tuffs, R J; Vieira, J D; van der Werf, P P; Zmuidzinas, J

    2010-11-05

    Gravitational lensing is a powerful astrophysical and cosmological probe and is particularly valuable at submillimeter wavelengths for the study of the statistical and individual properties of dusty star-forming galaxies. However, the identification of gravitational lenses is often time-intensive, involving the sifting of large volumes of imaging or spectroscopic data to find few candidates. We used early data from the Herschel Astrophysical Terahertz Large Area Survey to demonstrate that wide-area submillimeter surveys can simply and easily detect strong gravitational lensing events, with close to 100% efficiency.

  13. Surface wettability enhancement of silicone hydrogel lenses by processing with polar plastic molds.

    Science.gov (United States)

    Lai, Y C; Friends, G D

    1997-06-05

    In the quest for hydrogel contact lenses with improved extended wear capability, the use of siloxane moieties in the lens materials was investigated. However, the introduction of hydrophobic siloxane groups gave rise to wettability and lipidlike deposit problems. It was found that when polysiloxane-based compositions for hydrogels were processed with polar plastic molds, such as those fabricated from an acrylonitrile-based polymer, the hydrogel lenses fabricated were wettable, with minimized lipidlike deposits. These findings were supported by the wettability of silicone hydrogel films, silicon, and nitrogen element contents near lens surfaces, as well as the results from clinical assessment of silicone hydrogel lenses.

  14. [The application of highly hydrophilic contact lenses in the Fuchs-Steven-Johnson syndrome (author's transl)].

    Science.gov (United States)

    Schulz, E

    1979-01-01

    In 3 patients with status after Fuchs-Steven-Johnson syndrome highly hydrophilic contact lenses (72% H2O-up take) were adapted and worn permanently. 2 patients had worn already for a long time usual HEMA-lenses. The lenses showed themselves to be favorable against mechanical irritation from cilia and accessory eyelashes and from scarring conjunctival conditions, and they affected favorably the signs of dessication of the cornea. Corneal defects healed, and the patients had subjectively no complaints. It is sometimes necessary to replace the tears. An increase in the corneal vascularisation already present could not be observed during the 18 months observation time.

  15. Influence of the cosmological constant on gravitational lensing in small systems

    International Nuclear Information System (INIS)

    Sereno, Mauro

    2008-01-01

    The cosmological constant Λ affects gravitational lensing phenomena. The contribution of Λ to the observable angular positions of multiple images and to their amplification and time delay is here computed through a study of the weak deflection limit of the equations of motion in the Schwarzschild-de Sitter metric. Because of Λ the unresolved images are slightly demagnified, the radius of the Einstein ring decreases, and the time delay increases. The effect is however negligible for near lenses. In the case of a null cosmological constant, we provide some updated results on lensing by a Schwarzschild black hole

  16. Gravitational lensing: a unique probe of dark matter and dark energy

    Science.gov (United States)

    Ellis, Richard S.

    2010-01-01

    I review the development of gravitational lensing as a powerful tool of the observational cosmologist. After the historic eclipse expedition organized by Arthur Eddington and Frank Dyson, the subject lay observationally dormant for 60 years. However, subsequent progress has been astonishingly rapid, especially in the past decade, so that gravitational lensing now holds the key to unravelling the two most profound mysteries of our Universe—the nature and distribution of dark matter, and the origin of the puzzling cosmic acceleration first identified in the late 1990s. In this non-specialist review, I focus on the unusual history and achievements of gravitational lensing and its future observational prospects. PMID:20123743

  17. Process equipped with a sloped UV lamp for the fabrication of gradient-refractive-index lenses.

    Science.gov (United States)

    Liu, Jui-Hsiang; Chiu, Yi-Hong

    2009-05-01

    In this investigation, a method for the preparation of gradient-refractive-index (GRIN) lenses by UV-energy-controlled polymerization has been developed. A glass reaction tube equipped with a sloped UV lamp was designed. Methyl methacrylate and diphenyl sulfide were used as the reactive monomer and nonreactive dopant, respectively. Ciba IRGACURE 184 (1-hydroxy-cyclohexyl-phenyl-ketone) was used as the initiator. The effects of initiator concentration, the addition of acrylic polymers, and the preparation conditions on the optical characteristics of the GRIN lenses produced by this method were also investigated. Refractive index distributions and image transmission properties were estimated for all GRIN lenses prepared.

  18. Hard X-ray full field microscopy and magnifying microtomography using compound refractive lenses

    CERN Document Server

    Schrör, C; Benner, B; Kuhlmann, M; Tümmler, J; Lengeler, B; Rau, C; Weitkamp, T; Snigirev, A; Snigireva, I

    2001-01-01

    For hard X-rays, parabolic compound refractive lenses (PCRLs) are genuine imaging devices like glass lenses for visible light. Based on these new lenses, a hard X-ray full field microscope has been constructed that is ideally suited to image the interior of opaque samples with a minimum of sample preparation. As a result of a large depth of field, CRL micrographs are sharp projection images of most samples. To obtain 3D information about a sample, tomographic techniques are combined with magnified imaging.

  19. Age-related compaction of lens fibers affects the structure and optical properties of rabbit lenses

    Directory of Open Access Journals (Sweden)

    Al-Ghoul Walid M

    2007-12-01

    Full Text Available Abstract Background The goal of this investigation was to correlate particular age-related structural changes (compaction to the amount of scatter in rabbit lenses and to determine if significant fiber compaction occurred in the nuclear and inner cortical regions. Methods New Zealand White rabbits at 16–20 months old (adult; n = 10 and at 3.5–4 years old (aged; n = 10 were utilized for this study. Immediately after euthanising, scatter was assessed in fresh lenses by low power helium-neon laser scan analysis. Scatter data was analyzed both for whole lenses and regionally, to facilitate correlation with morphometric data. After functional analysis, lenses were fixed and processed for scanning electron microcopy (SEM; right eyes and light microscopy (LM; left eyes. Morphometric analysis of SEM images was utilized to evaluate compaction of nuclear fibers. Similarly, measurements from LM images were used to assess compaction of inner cortical fibers. Results Scatter was significantly greater in aged lenses as compared to adult lenses in all regions analyzed, however the difference in the mean was slightly more pronounced in the inner cortical region. The anterior and posterior elliptical angles at 1 mm (inner fetal nucleus were significantly decreased in aged vs. adult lenses (anterior, p = 0.040; posterior, p = 0.036. However, the average elliptical angles at 2.5 mm (outer fetal nucleus were not significantly different in adult and aged lenses since all lenses examined had comparable angles to inner fetal fibers of aged lenses, i.e. they were all compacted. In cortical fibers, measures of average cross-sectional fiber area were significantly different at diameters of both 6 and 7 mm as a function of age (p = 0.011 and p = 0.005, respectively. Accordingly, the estimated fiber volume was significantly decreased in aged as compared to adult lenses at both 6 mm diameter (p = 0.016 and 7 mm diameter (p = 0.010. Conclusion Morphometric data indicates

  20. Lenses in the forest: cross--correlation of the Lyman-alpha flux with CMB lensing

    Energy Technology Data Exchange (ETDEWEB)

    Vallinotto, Alberto; /Paris, Inst. Astrophys. /Fermilab; Das, Sudeep; /Princeton U. Observ. /Princeton U.; Spergel, David N.; /Princeton U. Observ. /APC, Paris; Viel, Matteo; /Trieste Observ. /INFN, Trieste

    2009-03-01

    We present a theoretical estimate for a new observable: the cross-correlation between the Lyman-{alpha}-flux fluctuations in quasar (QSO) spectra and the convergence of the cosmic microwave background (CMB) as measured along the same line-of-sight. As a first step toward the assessment of its detectability, we estimate the signal-to-noise ratio using linear theory. Although the signal-to-noise is small for a single line-of-sight and peaks at somewhat smaller redshifts than those probed by the Lyman-{alpha} forest, we estimate a total signal-to-noise of 9 for cross-correlating QSO spectra of SDSSIII with Planck and 20 for cross-correlating with a future polarization based CMB experiment. The detection of this effect would be a direct measure of the neutral hydrogen-matter cross-correlation and could provide important information on the growth of structures at large scales in a redshift range which is still poorly probed by observations.

  1. A Measurement of CMB Cluster Lensing with SPT and DES Year 1 Data

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, E.J.; et al.

    2017-08-03

    Clusters of galaxies gravitationally lens the cosmic microwave background (CMB) radiation, resulting in a distinct imprint in the CMB on arcminute scales. Measurement of this effect offers a promising way to constrain the masses of galaxy clusters, particularly those at high redshift. We use CMB maps from the South Pole Telescope Sunyaev-Zel'dovich (SZ) survey to measure the CMB lensing signal around galaxy clusters identified in optical imaging from first year observations of the Dark Energy Survey. We detect lensing of the CMB by the galaxy clusters at 6.5$\\sigma$ significance. Using the measured lensing signal, we constrain the amplitude of the relation between cluster mass and optical richness to roughly $20\\%$ precision, finding good agreement with recent constraints obtained with galaxy lensing. The error budget is dominated by statistical noise but includes significant contributions from systematic biases due to the thermal SZ effect and cluster miscentering.

  2. SOURCE-PLANE RECONSTRUCTION OF THE BRIGHT LENSED GALAXY RCSGA 032727-132609

    Energy Technology Data Exchange (ETDEWEB)

    Sharon, Keren; Gladders, Michael D.; Wuyts, Eva; Bayliss, Matthew B. [Kavli Institute for Cosmological Physics, University of Chicago, 5640 South Ellis Avenue, Chicago, IL 60637 (United States); Rigby, Jane R. [Observational Cosmology Laboratory, NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Koester, Benjamin P. [Department of Astronomy and Astrophysics, University of Chicago, 5640 South Ellis Avenue, Chicago, IL 60637 (United States); Barrientos, L. Felipe, E-mail: kerens@kicp.uchicago.edu [Departamento de Astronomia y Astrofisica, Pontificia Universidad Catolica de Chile, Avda. Vicuna Mackenna 4860, Casilla 306, Santiago 22 (Chile)

    2012-02-20

    We present new Hubble Space Telescope/Wide Field Camera 3 imaging data of RCSGA 032727-132609, a bright lensed galaxy at z = 1.7 that is magnified and stretched by the lensing cluster RCS2 032727-132623. Using this new high-resolution imaging, we modify our previous lens model (which was based on ground-based data) to fully understand the lensing geometry, and use it to reconstruct the lensed galaxy in the source plane. This giant arc represents a unique opportunity to peer into 100 pc scale structures in a high-redshift galaxy. This new source reconstruction will be crucial for a future analysis of the spatially resolved rest-UV and rest-optical spectra of the brightest parts of the arc.

  3. Defect inspection of actuator lenses using swept-source optical coherence tomography

    Science.gov (United States)

    Lee, Jaeyul; Shirazi, Muhammad Faizan; Park, Kibeom; Jeon, Mansik; Kim, Jeehyun

    2017-12-01

    Actuator lens industries have gained an enormous interest with the enhancement of various latest communication devices, such as mobile phone and notebooks. The quality of the aforementioned devices can be degraded due to the internal defects of actuator lenses. Therefore, in this study, we implemented swept-source optical coherence tomography (SS-OCT) system to inspect defects of actuator lenses. Owing to the high-resolution of the SS-OCT system, defected foreign substances between the actuator lenses, defective regions of lenses and surface stains were more clearly distinguished through three-dimensional (3D) and two-dimensional (2D) cross-sectional OCT images. Therefore, the implemented SS-OCT system can be considered as a potential application to defect inspection of actuator lens.

  4. Quantifying the line-of-sight mass distributions for time-delay lenses with stellar masses

    NARCIS (Netherlands)

    Rusu, Cristian; Fassnacht, Chris; Treu, Tommaso; Suyu, Sherry; Auger, Matt; Koopmans, Leon; Marshall, Phil; Wong, Kenneth; Collett, Thomas; Agnello, Adriano; Blandford, Roger; Courbin, Frederic; Hilbert, Stefan; Meylan, Georges; Sluse, Dominique

    2014-01-01

    Measuring cosmological parameters with a realistic account of systematic uncertainties is currently one of the principal challenges of physical cosmology. Building on our recent successes with two gravitationally lensed systems, we have started a program to achieve accurate cosmographic measurements

  5. SUNYAEV-ZEL'DOVICH EFFECT OBSERVATIONS OF STRONG LENSING GALAXY CLUSTERS: PROBING THE OVERCONCENTRATION PROBLEM

    International Nuclear Information System (INIS)

    Gralla, Megan B.; Gladders, Michael D.; Marrone, Daniel P.; Bayliss, Matthew; Carlstrom, John E.; Greer, Christopher; Hennessy, Ryan; Koester, Benjamin; Leitch, Erik; Sharon, Keren; Barrientos, L. Felipe; Bonamente, Massimiliano; Bulbul, Esra; Hasler, Nicole; Culverhouse, Thomas; Hawkins, David; Lamb, James; Gilbank, David G.; Joy, Marshall; Miller, Amber

    2011-01-01

    We have measured the Sunyaev-Zel'dovich (SZ) effect for a sample of 10 strong lensing selected galaxy clusters using the Sunyaev-Zel'dovich Array (SZA). The SZA is sensitive to structures on spatial scales of a few arcminutes, while the strong lensing mass modeling constrains the mass at small scales (typically <30''). Combining the two provides information about the projected concentrations of the strong lensing clusters. The Einstein radii we measure are twice as large as expected given the masses inferred from SZ scaling relations. A Monte Carlo simulation indicates that a sample randomly drawn from the expected distribution would have a larger median Einstein radius than the observed clusters about 3% of the time. The implied overconcentration has been noted in previous studies and persists for this sample, even when we take into account that we are selecting large Einstein radius systems, suggesting that the theoretical models still do not fully describe the observed properties of strong lensing clusters.

  6. Microbiologic Examination of Bandage Contact Lenses Used after Corneal Collagen Cross-linking Treatment.

    Science.gov (United States)

    Yuksel, Erdem; Yalcin, Nuriye Gokçen; Kilic, Gaye; Cubuk, Mehmet Ozgur; Ozmen, Mehmet Cuneyt; Altay, Aylin; Çağlar, Kayhan; Bilgihan, Kamil

    2016-01-01

    To investigate the agents of bacterial contamination of contact lenses after corneal collagen cross-linking (CCL), and to present the possible changes of ocular flora after riboflavin/ultraviolet A. Seventy-two contact lenses of patients who underwent CCL and 41 contact lenses of patients who underwent photorefractive keratectomy (PRK) as control group were enrolled to the study. After 48 h of incubation, broth culture media was transferred to plates. Samples were accepted as positive if one or more colony-forming units were shown. There were positive cultures in 12 (16.7%) contact lenses in the CCL group and 5 (12.2%) had positive cultures in PRK group. Coagulase-negative staphlycocci (CNS) were the most frequent microorganism. Alpha hemolytic streptococci and Diphteroid spp. were the other isolated microorganisms. Bacterial colonization can occur during and early after the CCL procedure in epithelial healing. To prevent corneal infections after the treatment, prophylactic antibiotics should be prescribed.

  7. Absorption of ammonia by high water content hydrogel lenses: an inexpensive method of analysis.

    Science.gov (United States)

    LaMotte, J; Smith, G; Chang-Smith, A

    1995-09-01

    Few studies have been done on the absorption and release of chemical vapors by high water content hydrogel lenses. In this study we investigated the absorption of ammonia vapors by this type of contact lens (CL). Ten high water content hydrogel lenses were exposed to vapor generated in a cuvette by 1 drop of aqueous ammonia. The contact lens was transferred to a 0.9% saline solution containing a colorometric indicator for ammonia and the amount of ammonia released into the saline was measured. We found that significant quantities of ammonia were absorbed into the lenses and the relation between average concentration of ammonia vapor and amount absorbed per contact lens was nearly linear from 50 parts per million (ppm) to 250 ppm ammonia vapor. For concentrations greater than 250 ppm there appears to be a saturation effect. Our findings indicate that high water contact lenses will absorb ammonia and release it into a solution similar to tears.

  8. Visual management of aphakia with concomitant severe corneal irregularity by mini-scleral design contact lenses

    Directory of Open Access Journals (Sweden)

    Fateme Alipur

    2016-03-01

    Conclusion: Miniscleral contact lenses can be considered a safe and effective option in aphakia patients with concurrent corneal scarring secondary to ocular injury for whom surgical intervention would be complicated.

  9. [Importance of asferic treatment of intraocular lenses in contrast sensitivity of the human eye].

    Science.gov (United States)

    Calţaru, Dana Cristina; Pop, Mihai

    2014-01-01

    Clinical study which follows the influence of asphericity of intraocular lenses on an important parameter of quality of vision in operated cataract patients - contrast sensibility. This is a pilot, prospective study with 131 eyes of 124 patients, which had cataract surgery by phacoemulsification between 2011-2012. All operations were done by the same surgeon. EXCLUSION CRITERIAS WERE: VA ( 0.7; postop refraction >0.75 D sf. or 0.75 D cyl, corneal diseases, optic nerv or retinal pathologies, atypical surgery, pupil diameter 3 mm. Postoperative control was done at six weeks and included : AV, optical correction, contrast sensibility testing, intraocular pressure, posterior pol exam. Contrast sensibility testing was done using a LCD device, in fotopic condition, CC-100 TOPCON. Contrast sensibility graphics were compared between spheric and aspheric lenses for Zeiss, AMO, Bausch&Lomb, Alcon. There were no statistically significant differences between aspherical lenses. Also, there were no differences for the same manufacturer between spherical and aspherical lenses.

  10. GEMINI/GMOS SPECTROSCOPY OF 26 STRONG-LENSING-SELECTED GALAXY CLUSTER CORES

    International Nuclear Information System (INIS)

    Bayliss, Matthew B.; Gladders, Michael D.; Koester, Benjamin P.; Hennawi, Joseph F.; Sharon, Keren; Dahle, Haakon; Oguri, Masamune

    2011-01-01

    We present results from a spectroscopic program targeting 26 strong-lensing cluster cores that were visually identified in the Sloan Digital Sky Survey (SDSS) and the Second Red-Sequence Cluster Survey (RCS-2). The 26 galaxy cluster lenses span a redshift range of 0.2 Vir = 7.84 x 10 14 M sun h -1 0.7 , which is somewhat higher than predictions for strong-lensing-selected clusters in simulations. The disagreement is not significant considering the large uncertainty in our dynamical data, systematic uncertainties in the velocity dispersion calibration, and limitations of the theoretical modeling. Nevertheless our study represents an important first step toward characterizing large samples of clusters that are identified in a systematic way as systems exhibiting dramatic strong-lensing features.

  11. Quasar lenses and galactic streams: outlier selection and Gaia multiplet detection

    Science.gov (United States)

    Agnello, Adriano

    2017-10-01

    I describe two novel techniques originally devised to select strongly lensed quasar candidates in wide-field surveys. The first relies on outlier selection in optical and mid-infrared magnitude space; the second combines mid-infrared colour selection with Gaia spatial resolution, to identify multiplets of objects with quasar-like colours. Both methods have already been applied successfully to the Sloan Digital Sky Survey, ATLAS and Dark Energy Survey footprints: besides recovering known lenses from previous searches, they have led to new discoveries, including quadruply lensed quasars, which are rare within the rare-object class of quasar lenses. As a serendipitous by-product, at least four candidate Galactic streams in the South have been identified among foreground contaminants. There is considerable scope for tailoring the WISE-Gaia multiplet search to stellar-like objects, instead of quasar-like, and to automatically detect Galactic streams.

  12. iPTF16geu: A multiply imaged, gravitationally lensed type Ia supernova.

    Science.gov (United States)

    Goobar, A; Amanullah, R; Kulkarni, S R; Nugent, P E; Johansson, J; Steidel, C; Law, D; Mörtsell, E; Quimby, R; Blagorodnova, N; Brandeker, A; Cao, Y; Cooray, A; Ferretti, R; Fremling, C; Hangard, L; Kasliwal, M; Kupfer, T; Lunnan, R; Masci, F; Miller, A A; Nayyeri, H; Neill, J D; Ofek, E O; Papadogiannakis, S; Petrushevska, T; Ravi, V; Sollerman, J; Sullivan, M; Taddia, F; Walters, R; Wilson, D; Yan, L; Yaron, O

    2017-04-21

    We report the discovery of a multiply imaged, gravitationally lensed type Ia supernova, iPTF16geu (SN 2016geu), at redshift z = 0.409. This phenomenon was identified because the light from the stellar explosion was magnified more than 50 times by the curvature of space around matter in an intervening galaxy. We used high-spatial-resolution observations to resolve four images of the lensed supernova, approximately 0.3 arc seconds from the center of the foreground galaxy. The observations probe a physical scale of ~1 kiloparsec, smaller than is typical in other studies of extragalactic gravitational lensing. The large magnification and symmetric image configuration imply close alignment between the lines of sight to the supernova and to the lens. The relative magnifications of the four images provide evidence for substructures in the lensing galaxy. Copyright © 2017, American Association for the Advancement of Science.

  13. Combined pars plana lensectomy-vitrectomy with open-loop flexible anterior chamber intraocular lens (AC IOL) implantation for subluxated lenses.

    Science.gov (United States)

    Kazemi, S; Wirostko, W J; Sinha, S; Mieler, W F; Koenig, S B; Sheth, B P

    2000-01-01

    To review our experience with combined pars plana lensectomy-vitrectomy and open-loop flexible anterior chamber intraocular lens (AC IOL) implantation for managing subluxated crystalline lenses. Retrospective review of 36 consecutive eyes (28 patients), all of which had subluxated crystalline lenses, managed by pars plana lensectomy-vitrectomy with insertion of an open-loop flexible AC IOL. The study was performed at the Medical College of Wisconsin, Milwaukee, over an 8-year period. An average preoperative visual acuity of 20/163 (range, 20/25 to hand motions) improved to 20/36 (range, 20/20 to 4/200) with surgery after a mean follow-up of 14 months (range, 1 to 59 months) (P IOL implantation appears to be an excellent technique for managing subluxated crystalline lenses. It is associated with a significant improvement in visual acuity (P subluxated lens through a limbal wound. Additionally, use of an AC IOL offers a simplified alternative to placement of a ciliary sulcus sutured posterior chamber intraocular lens (PC IOL).

  14. Statistical and systematic errors in the measurement of weak-lensing Minkowski functionals: Application to the Canada-France-Hawaii Lensing Survey

    Energy Technology Data Exchange (ETDEWEB)

    Shirasaki, Masato; Yoshida, Naoki, E-mail: masato.shirasaki@utap.phys.s.u-tokyo.ac.jp [Department of Physics, University of Tokyo, Tokyo 113-0033 (Japan)

    2014-05-01

    The measurement of cosmic shear using weak gravitational lensing is a challenging task that involves a number of complicated procedures. We study in detail the systematic errors in the measurement of weak-lensing Minkowski Functionals (MFs). Specifically, we focus on systematics associated with galaxy shape measurements, photometric redshift errors, and shear calibration correction. We first generate mock weak-lensing catalogs that directly incorporate the actual observational characteristics of the Canada-France-Hawaii Lensing Survey (CFHTLenS). We then perform a Fisher analysis using the large set of mock catalogs for various cosmological models. We find that the statistical error associated with the observational effects degrades the cosmological parameter constraints by a factor of a few. The Subaru Hyper Suprime-Cam (HSC) survey with a sky coverage of ∼1400 deg{sup 2} will constrain the dark energy equation of the state parameter with an error of Δw {sub 0} ∼ 0.25 by the lensing MFs alone, but biases induced by the systematics can be comparable to the 1σ error. We conclude that the lensing MFs are powerful statistics beyond the two-point statistics only if well-calibrated measurement of both the redshifts and the shapes of source galaxies is performed. Finally, we analyze the CFHTLenS data to explore the ability of the MFs to break degeneracies between a few cosmological parameters. Using a combined analysis of the MFs and the shear correlation function, we derive the matter density Ω{sub m0}=0.256±{sub 0.046}{sup 0.054}.

  15. Soft contact lenses: Basic characteristics, advantages and complications associated with their use

    Directory of Open Access Journals (Sweden)

    Milosavljević Miloš

    2016-01-01

    Full Text Available Soft contact lenses have an important place in ophthalmology, both for the correction of refractive anomalies and tor the treatment of some eye diseases. From the moment when adequately biocompatible materials were found, for a very sensitive environment such as the human eye, from early 60s of the 20th century, starts irrepressible expansion of soft contact lenses. The reason for this expansion of soft contact lenses lies in advantages they undoubtedly have in comparison to glasses, but also in comparison to hard and semi-hard contact lenses. Unfortunately, in parallel with the increasing number of users of this type of optical aids, increases the incidence of complications that can arise. Complications can be very diverse in nature and severity, and they can be classified into three major groups: symptoms of eye dryness, infections and allergic-toxic complications. Symptoms of dry eye are very common for users of contact lenses, and their occurrence is especially provoked by certain factors, such as cigarette smoke or prolonged watching the computer screen or TV. These complications are usually not so dangerous and can easily be solved by applying artificial tears. Infections are not so common and occur as a result of inadequate maintenance of contact lenses. If the symptoms are recognized early, infections are mostly stopped at the level of conjunctivitis and are treated fairly quickly and easily. Otherwise, the infection can progress to ulcerative keratitis, the most severe complication of inadequate application of soft contact lenses, and in some cases it can even lead to blindness. Allergic-toxic complications generally occur in susceptible persons and their occurrence in most cases means contraindication for further wearing of soft contact lenses. This case report underlines possible role of rheumatoid factor in estimation of the patient's response to administered therapy.

  16. Pathogenic Free-Living Amoebae Isolated From Contact Lenses of Keratitis Patients

    OpenAIRE

    HAJIALILO, Elham; NIYYATI, Maryam; SOLAYMANI, Mohammad; REZAEIAN, Mostafa

    2015-01-01

    Background: Free-living amoeba (FLA)-related keratitis is a progressive infection of the cornea with poor prognosis. The present study aimed to investigates the con­tact lenses of patients with keratitis for pathogenic free-living amoebae.Methods: Overall, 62 contact lenses and their paraphernalia of patients with kerati­tis cultured and tested for the presence of free-living amoebae using morphological criteria. Unusual plates including plates containing mix amoebae and Vermamoeba were submi...

  17. Probing the dark side of the Universe with weak gravitational lensing effects

    International Nuclear Information System (INIS)

    Fu Li-Ping; Fan Zu-Hui

    2014-01-01

    Arising from gravitational deflections of light rays by large-scale structures in the Universe, weak-lensing effects have been recognized as one of the most important probes in cosmological studies. In this paper, we review the main progress in weak-lensing analyses, and discuss the challenges in future investigations aiming to understand the dark side of the Universe with unprecedented precisions. (invited reviews)

  18. Microbial contamination of soft contact lenses & accessories in asymptomatic contact lens users

    OpenAIRE

    Deeksha V Thakur; Ujjwala N Gaikwad

    2014-01-01

    Background & objectives: With increasing use of soft contact lenses the incidence of contact lens induced infections is also increasing. This study was aimed to assess the knowledge of new and existing contact lens users about the risk of microbial contamination associated with improper use and maintenance of contact lenses, type of microbial flora involved and their potential to cause ophthalmic infections. Methods: Four samples each from 50 participants (n=200) were collected from the l...

  19. Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics

    OpenAIRE

    Kim, Joohee; Kim, Minji; Lee, Mi-Sun; Kim, Kukjoo; Ji, Sangyoon; Kim, Yun-Tae; Park, Jihun; Na, Kyungmin; Bae, Kwi-Hyun; Kyun Kim, Hong; Bien, Franklin; Young Lee, Chang; Park, Jang-Ung

    2017-01-01

    Wearable contact lenses which can monitor physiological parameters have attracted substantial interests due to the capability of direct detection of biomarkers contained in body fluids. However, previously reported contact lens sensors can only monitor a single analyte at a time. Furthermore, such ocular contact lenses generally obstruct the field of vision of the subject. Here, we developed a multifunctional contact lens sensor that alleviates some of these limitations since it was developed...

  20. Jupiter scleral lenses in the management of chronic graft versus host disease.

    Science.gov (United States)

    Schornack, Muriel M; Baratz, Keith H; Patel, Sanjay V; Maguire, Leo J

    2008-11-01

    To describe the use of the Jupiter scleral contact lens (Medlens Innovations, Front Royal, VA or Essilor Contact Lens, Inc., Dallas, TX) in the management of ocular manifestations of chronic graft versus host disease (cGVHD). This study is a retrospective case series. Five consecutive patients with severe keratoconjunctivitis sicca (KCS) associated with cGVHD that could not be adequately managed with conventional therapy were evaluated for scleral contact lens wear between January and December 2007. All patients were evaluated with lenses from the standard 18.2 mm Jupiter B diagnostic fitting set. If lenses of standard design failed to provide adequate fit, custom lenses were designed. Three outcome measures were evaluated: the patient's ability to tolerate and successfully handle the lenses, improvement in symptoms of KCS, and improvement in visual acuity. All 5 patients (10 eyes) were successfully fit with Jupiter scleral lenses. Six eyes of 3 patients were successfully fit with lenses of standard design. Standard parameters were altered to achieve adequate fit in 4 eyes of 2 patients. All patients reported subjective improvements in comfort with Jupiter scleral lenses, and best-corrected vision improved in 7 of the 10 eyes fit within the first several months of contact lens wear. The remaining 3 eyes maintained the visual acuity measured before scleral lens wear (20/20 in 2 eyes, 20/40 in 1 eye). Duration of follow-up ranged from 4 to 14 months. Jupiter scleral lenses can relieve symptoms of KCS and may improve vision in patients with cGVHD.

  1. Objective and subjective performance of scleral lenses and new advances in scleral lens technologies

    OpenAIRE

    Visser, E.S.

    2015-01-01

    Scleral lenses are widely recognized for their ability to markedly improve quality of life and giving back patients their ability to perform daily activities, mainly as a result of restoring visual function and/or reduction of ocular discomfort and pain.Scleral lenses are an important front-line tool for managing many corneal disorders refractory to other treatment measures and that otherwise would require keratoplasty. These disorders include conditions in which the cornea requires suitable ...

  2. Therapeutic use of mini-scleral lenses in a patient with Graves’ ophthalmopathy

    Directory of Open Access Journals (Sweden)

    Jennifer S. Harthan

    2014-01-01

    We present here the case of a 48-year-old Caucasian male who had been diagnosed with Graves’ ophthalmopathy 13 years earlier. With significant ocular surface staining and over ten diopters of astigmatism, the patient had never been able to wear contact lenses comfortably. After being fit with the Mini-Scleral Design™ lenses, his vision improved to 20/25 OU, his ocular surface improved, and overall quality of vision increased.

  3. ALMA observations of lensed Herschel sources: testing the dark matter halo paradigm

    Science.gov (United States)

    Amvrosiadis, A.; Eales, S. A.; Negrello, M.; Marchetti, L.; Smith, M. W. L.; Bourne, N.; Clements, D. L.; De Zotti, G.; Dunne, L.; Dye, S.; Furlanetto, C.; Ivison, R. J.; Maddox, S. J.; Valiante, E.; Baes, M.; Baker, A. J.; Cooray, A.; Crawford, S. M.; Frayer, D.; Harris, A.; Michałowski, M. J.; Nayyeri, H.; Oliver, S.; Riechers, D. A.; Serjeant, S.; Vaccari, M.

    2018-04-01

    With the advent of wide-area submillimetre surveys, a large number of high-redshift gravitationally lensed dusty star-forming galaxies have been revealed. Because of the simplicity of the selection criteria for candidate lensed sources in such surveys, identified as those with S500 μm > 100 mJy, uncertainties associated with the modelling of the selection function are expunged. The combination of these attributes makes submillimetre surveys ideal for the study of strong lens statistics. We carried out a pilot study of the lensing statistics of submillimetre-selected sources by making observations with the Atacama Large Millimeter Array (ALMA) of a sample of strongly lensed sources selected from surveys carried out with the Herschel Space Observatory. We attempted to reproduce the distribution of image separations for the lensed sources using a halo mass function taken from a numerical simulation that contains both dark matter and baryons. We used three different density distributions, one based on analytical fits to the haloes formed in the EAGLE simulation and two density distributions [Singular Isothermal Sphere (SIS) and SISSA] that have been used before in lensing studies. We found that we could reproduce the observed distribution with all three density distributions, as long as we imposed an upper mass transition of ˜1013 M⊙ for the SIS and SISSA models, above which we assumed that the density distribution could be represented by a Navarro-Frenk-White profile. We show that we would need a sample of ˜500 lensed sources to distinguish between the density distributions, which is practical given the predicted number of lensed sources in the Herschel surveys.

  4. LENS MODEL AND TIME DELAY PREDICTIONS FOR THE SEXTUPLY LENSED QUASAR SDSS J2222+2745

    Energy Technology Data Exchange (ETDEWEB)

    Sharon, Keren; Johnson, Traci L.; Paterno-Mahler, Rachel [Department of Astronomy, University of Michigan, 1085 S. University Avenue, Ann Arbor, MI 48109 (United States); Bayliss, Matthew B. [Colby College, 5800 Mayflower Hill, Waterville, 04901, Maine (United States); Dahle, Håkon [Institute of Theoretical Astrophysics, University of Oslo, P.O. Box 1029, Blindern, NO-0315 Oslo (Norway); Florian, Michael K.; Gladders, Michael D. [Department of Astronomy and Astrophysics, University of Chicago, 5640 South Ellis Avenue, Chicago, IL 60637 (United States); Rigby, Jane R. [Astrophysics Science Division, Goddard Space Flight Center, 8800 Greenbelt Road, Greenbelt, MD 20771 (United States); Whitaker, Katherine E. [Department of Astronomy, University of Massachusetts-Amherst, Amherst, MA 01003 (United States); Wuyts, Eva, E-mail: kerens@umich.edu [Max-Planck-Institut für extraterrestrische Physik, Giessenbachstr. 1, D-85741 Garching (Germany)

    2017-01-20

    SDSS J2222+2745 is a galaxy cluster at z = 0.49, strongly lensing a quasar at z = 2.805 into six widely separated images. In recent Hubble Space Telescope imaging of the field, we identify additional multiply lensed galaxies and confirm the sixth quasar image that was identified by Dahle et al. We used the Gemini-North telescope to measure a spectroscopic redshift of z = 4.56 of one of the lensed galaxies. These data are used to refine the lens model of SDSS J2222+2745, compute the time delay and magnifications of the lensed quasar images, and reconstruct the source image of the quasar host and a lensed galaxy at z = 2.3. This galaxy also appears in absorption in our Gemini spectra of the lensed quasar, at a projected distance of 34 kpc. Our model is in agreement with the recent time delay measurements of Dahle et al., who found τ {sub AB} = 47.7 ± 6.0 days and τ {sub AC} = −722 ± 24 days. We use the observed time delays to further constrain the model, and find that the model-predicted time delays of the three faint images of the quasar are τ {sub AD} = 502 ± 68 days, τ {sub AE} = 611 ± 75 days, and τ {sub AF} = 415 ± 72 days. We have initiated a follow-up campaign to measure these time delays with Gemini North. Finally, we present initial results from an X-ray monitoring program with Swift , indicating the presence of hard X-ray emission from the lensed quasar, as well as extended X-ray emission from the cluster itself, which is consistent with the lensing mass measurement and the cluster velocity dispersion.

  5. Finding strong gravitational lenses in the Kilo Degree Survey with Convolutional Neural Networks

    Science.gov (United States)

    Petrillo, C. E.; Tortora, C.; Chatterjee, S.; Vernardos, G.; Koopmans, L. V. E.; Verdoes Kleijn, G.; Napolitano, N. R.; Covone, G.; Schneider, P.; Grado, A.; McFarland, J.

    2017-11-01

    The volume of data that will be produced by new-generation surveys requires automatic classification methods to select and analyse sources. Indeed, this is the case for the search for strong gravitational lenses, where the population of the detectable lensed sources is only a very small fraction of the full source population. We apply for the first time a morphological classification method based on a Convolutional Neural Network (CNN) for recognizing strong gravitational lenses in 255 deg2 of the Kilo Degree Survey (KiDS), one of the current-generation optical wide surveys. The CNN is currently optimized to recognize lenses with Einstein radii ≳1.4 arcsec, about twice the r-band seeing in KiDS. In a sample of 21 789 colour-magnitude selected luminous red galaxies (LRGs), of which three are known lenses, the CNN retrieves 761 strong-lens candidates and correctly classifies two out of three of the known lenses. The misclassified lens has an Einstein radius below the range on which the algorithm is trained. We down-select the most reliable 56 candidates by a joint visual inspection. This final sample is presented and discussed. A conservative estimate based on our results shows that with our proposed method it should be possible to find ∼100 massive LRG-galaxy lenses at z ≲ 0.4 in KiDS when completed. In the most optimistic scenario, this number can grow considerably (to maximally ∼2400 lenses), when widening the colour-magnitude selection and training the CNN to recognize smaller image-separation lens systems.

  6. Glutathione Preservation during Storage of Rat Lenses in Optisol-GS and Castor Oil

    DEFF Research Database (Denmark)

    Holm, Thomas; Brøgger-Jensen, Martin Rocho; Johnson, Leif

    2013-01-01

    Glutathione concentration in the lens decreases in aging and cataractous lenses, providing a marker for tissue condition. Experimental procedures requiring unfrozen lenses from donor banks rely on transportation in storage medium, affecting lens homeostasis and alterations in glutathione levels. ....... The aim of the study was to examine the effects of Optisol-GS and castor oil on lens condition, determined from their ability to maintain glutathione concentrations....

  7. Constraining the neutrino emission of gravitationally lensed Flat-Spectrum Radio Quasars with ANTARES data

    OpenAIRE

    Adrian-Martinez, S.; Albert, A.; Andre, M.; Anton, G.; Ardid, M.; Aubert, J. J.; Baret, B.; Barrios-Marti, J.; Basa, S.; Bertin, V.; Biagii, S.; Bogazzi, C.; Bormuth, R.; Bou-Cabo, M.; Bouwhuis, M. C.

    2014-01-01

    This paper proposes to exploit gravitational lensing effects to improve the sensitivity of neutrino telescopes to the intrinsic neutrino emission of distant blazar populations. This strategy is illustrated with a search for cosmic neutrinos in the direction of four distant and gravitationally lensed Flat-Spectrum Radio Quasars. The magnification factor is estimated for each system assuming a singular isothermal profile for the lens. Based on data collected from 2007 to 2012 by the ANTARES neu...

  8. ALMA observations of lensed Herschel sources : Testing the dark-matter halo paradigm

    Science.gov (United States)

    Amvrosiadis, A.; Eales, S. A.; Negrello, M.; Marchetti, L.; Smith, M. W. L.; Bourne, N.; Clements, D. L.; De Zotti, G.; Dunne, L.; Dye, S.; Furlanetto, C.; Ivison, R. J.; Maddox, S.; Valiante, E.; Baes, M.; Baker, A. J.; Cooray, A.; Crawford, S. M.; Frayer, D.; Harris, A.; Michałowski, M. J.; Nayyeri, H.; Oliver, S.; Riechers, D. A.; Serjeant, S.; Vaccari, M.

    2018-01-01

    With the advent of wide-area submillimeter surveys, a large number of high-redshift gravitationally lensed dusty star-forming galaxies (DSFGs) has been revealed. Due to the simplicity of the selection criteria for candidate lensed sources in such surveys, identified as those with S500μm > 100 mJy, uncertainties associated with the modelling of the selection function are expunged. The combination of these attributes makes submillimeter surveys ideal for the study of strong lens statistics. We carried out a pilot study of the lensing statistics of submillimetre-selected sources by making observations with the Atacama Large Millimetre Array (ALMA) of a sample of strongly-lensed sources selected from surveys carried out with the Herschel Space Observatory. We attempted to reproduce the distribution of image separations for the lensed sources using a halo mass function taken from a numerical simulation which contains both dark matter and baryons. We used three different density distributions, one based on analytical fits to the halos formed in the EAGLE simulation and two density distributions (Singular Isothermal Sphere (SIS) and SISSA) that have been used before in lensing studies. We found that we could reproduce the observed distribution with all three density distributions, as long as we imposed an upper mass transition of ˜1013M⊙ for the SIS and SISSA models, above which we assumed that the density distribution could be represented by an NFW profile. We show that we would need a sample of ˜500 lensed sources to distinguish between the density distributions, which is practical given the predicted number of lensed sources in the Herschel surveys.

  9. Efflux and hydrolysis of phosphorylethanolamine and phosphorylcholine in stressed cultured rat lenses.

    Science.gov (United States)

    Jernigan, H M; Desouky, M A; Geller, A M; Blum, P S; Ekambaram, M C

    1993-01-01

    Phosphorylcholine (P-choline), and phosphorylethanolamine (P-ethanolamine) are among the organic phosphate compounds that decrease in concentration in some cataracts and in lenses that have been subjected to cataractogenic osmotic or oxidative stresses. Decreases in the lenticular concentrations of these compounds could be caused by decreased synthesis, increased utilization or hydrolysis, or increased efflux, or by a combination of these mechanisms. To distinguish between these possibilities, the P-choline and P-ethanolamine pools of intact cultured rat lenses were radiolabeled with [3H]choline or [3H]ethanolamine, and the lenses were then subjected to oxidative or osmotic stress. The efflux and hydrolysis of P-[3H]choline and P-[3H]ethanolamine were then followed for up to 48 hr. Osmotic stress induced by incubation with 30 mM xylose caused increased P-choline and P-ethanolamine efflux from the lenses, but had little effect on the rate of hydrolysis of these compounds. For example, xylose-treated lenses lost 26% of their initial P-[3H]ethanolamine content into the medium during a 24 hr incubation, compared with only 6% for control lenses. Oxidative stress from singlet oxygen (generated by rose bengal and light) also increased lenticular P-choline efflux three to four-fold, with minimal effects on hydrolysis, and the increased efflux was accompanied by a decrease in the P-choline concentration. Permeability increases also were observed in lenses oxidatively stressed by H2O2 or by riboflavin and light. These results show that a variety of cataractogenic stresses, both oxidative and osmotic, cause increased permeability of rat lenses to organic phosphate compounds, including P-choline and P-ethanolamine.(ABSTRACT TRUNCATED AT 250 WORDS)

  10. Flexible DWDM Grid Manipulation Using Four Wave Mixing-based Time Lenses

    DEFF Research Database (Denmark)

    Røge, Kasper Meldgaard; Guan, Pengyu; Mulvad, Hans Christian Hansen

    2014-01-01

    An experimental demonstration of dense wavelength-division multiplexing (DWDM) grid manipulation is carried out using two time lenses. A DWDM spectrum is compressed from a 100-GHz to a 28-GHz grid with error-free performance.......An experimental demonstration of dense wavelength-division multiplexing (DWDM) grid manipulation is carried out using two time lenses. A DWDM spectrum is compressed from a 100-GHz to a 28-GHz grid with error-free performance....

  11. Precision cosmology with time delay lenses: high resolution imaging requirements

    Energy Technology Data Exchange (ETDEWEB)

    Meng, Xiao-Lei; Liao, Kai [Department of Astronomy, Beijing Normal University, 19 Xinjiekouwai Street, Beijing, 100875 (China); Treu, Tommaso; Agnello, Adriano [Department of Physics, University of California, Broida Hall, Santa Barbara, CA 93106 (United States); Auger, Matthew W. [Institute of Astronomy, University of Cambridge, Madingley Road, Cambridge CB3 0HA (United Kingdom); Marshall, Philip J., E-mail: xlmeng919@gmail.com, E-mail: tt@astro.ucla.edu, E-mail: aagnello@physics.ucsb.edu, E-mail: mauger@ast.cam.ac.uk, E-mail: liaokai@mail.bnu.edu.cn, E-mail: dr.phil.marshall@gmail.com [Kavli Institute for Particle Astrophysics and Cosmology, Stanford University, 452 Lomita Mall, Stanford, CA 94305 (United States)

    2015-09-01

    Lens time delays are a powerful probe of cosmology, provided that the gravitational potential of the main deflector can be modeled with sufficient precision. Recent work has shown that this can be achieved by detailed modeling of the host galaxies of lensed quasars, which appear as ''Einstein Rings'' in high resolution images. The distortion of these arcs and counter-arcs, as measured over a large number of pixels, provides tight constraints on the difference between the gravitational potential between the quasar image positions, and thus on cosmology in combination with the measured time delay. We carry out a systematic exploration of the high resolution imaging required to exploit the thousands of lensed quasars that will be discovered by current and upcoming surveys with the next decade. Specifically, we simulate realistic lens systems as imaged by the Hubble Space Telescope (HST), James Webb Space Telescope (JWST), and ground based adaptive optics images taken with Keck or the Thirty Meter Telescope (TMT). We compare the performance of these pointed observations with that of images taken by the Euclid (VIS), Wide-Field Infrared Survey Telescope (WFIRST) and Large Synoptic Survey Telescope (LSST) surveys. We use as our metric the precision with which the slope γ' of the total mass density profile ρ{sub tot}∝ r{sup −γ'} for the main deflector can be measured. Ideally, we require that the statistical error on γ' be less than 0.02, such that it is subdominant to other sources of random and systematic uncertainties. We find that survey data will likely have sufficient depth and resolution to meet the target only for the brighter gravitational lens systems, comparable to those discovered by the SDSS survey. For fainter systems, that will be discovered by current and future surveys, targeted follow-up will be required. However, the exposure time required with upcoming facilitites such as JWST, the Keck Next Generation

  12. Precision cosmology with time delay lenses: High resolution imaging requirements

    Energy Technology Data Exchange (ETDEWEB)

    Meng, Xiao -Lei [Beijing Normal Univ., Beijing (China); Univ. of California, Santa Barbara, CA (United States); Treu, Tommaso [Univ. of California, Santa Barbara, CA (United States); Univ. of California, Los Angeles, CA (United States); Agnello, Adriano [Univ. of California, Santa Barbara, CA (United States); Univ. of California, Los Angeles, CA (United States); Auger, Matthew W. [Univ. of Cambridge, Cambridge (United Kingdom); Liao, Kai [Beijing Normal Univ., Beijing (China); Univ. of California, Santa Barbara, CA (United States); Univ. of California, Los Angeles, CA (United States); Marshall, Philip J. [Stanford Univ., Stanford, CA (United States)

    2015-09-28

    Lens time delays are a powerful probe of cosmology, provided that the gravitational potential of the main deflector can be modeled with sufficient precision. Recent work has shown that this can be achieved by detailed modeling of the host galaxies of lensed quasars, which appear as ``Einstein Rings'' in high resolution images. The distortion of these arcs and counter-arcs, as measured over a large number of pixels, provides tight constraints on the difference between the gravitational potential between the quasar image positions, and thus on cosmology in combination with the measured time delay. We carry out a systematic exploration of the high resolution imaging required to exploit the thousands of lensed quasars that will be discovered by current and upcoming surveys with the next decade. Specifically, we simulate realistic lens systems as imaged by the Hubble Space Telescope (HST), James Webb Space Telescope (JWST), and ground based adaptive optics images taken with Keck or the Thirty Meter Telescope (TMT). We compare the performance of these pointed observations with that of images taken by the Euclid (VIS), Wide-Field Infrared Survey Telescope (WFIRST) and Large Synoptic Survey Telescope (LSST) surveys. We use as our metric the precision with which the slope γ' of the total mass density profile ρtot∝ r–γ' for the main deflector can be measured. Ideally, we require that the statistical error on γ' be less than 0.02, such that it is subdominant to other sources of random and systematic uncertainties. We find that survey data will likely have sufficient depth and resolution to meet the target only for the brighter gravitational lens systems, comparable to those discovered by the SDSS survey. For fainter systems, that will be discovered by current and future surveys, targeted follow-up will be required. Furthermore, the exposure time required with upcoming facilitites such as JWST, the Keck Next Generation Adaptive

  13. Image formation in weak gravitational lensing by tidal charged black holes

    International Nuclear Information System (INIS)

    Horvath, Zsolt; Gergely, Laszlo Arpad; Hobill, David

    2010-01-01

    We derive a generic weak lensing equation and apply it for the study of images produced by tidal charged brane black holes. We discuss the similarities and point out the differences with respect to the Schwarzschild black hole weak lensing, to both first- and second-order accuracy, when either the mass or the tidal charge dominates. In the case of mass-dominated weak lensing, we analyze the position of the images, the magnification factors and the flux ratio, as compared to the Schwarzschild lensing. The most striking modification appears in the flux ratio. When the tidal charge represents the dominating lensing effect, the number and orientation of the images with respect to the optical axis resembles the lensing properties of a Schwarzschild geometry, where the sign associated with the mass is opposite to that for the tidal charge. Finally it is found that the ratio of the brightness of the images as a function of image separation in the case of tidal charged black holes obeys a power-law relation significantly different from that of Schwarzschild black holes. This might provide a means for determining the underlying spacetime structure.

  14. Detecting Gravitational Lensing of the Cosmic Microwave Background by Galaxy Clusters

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Eric Jones [Univ. of Chicago, IL (United States)

    2014-08-01

    Clusters of galaxies gravitationally lens the Cosmic Microwave Background (CMB) leading to a distinct signal in the CMB on arcminute scales. Measurement of the cluster lensing effect offers the exciting possibility of constraining the masses of galaxy clusters using CMB data alone. Improved constraints on cluster masses are in turn essential to the use of clusters as cosmological probes: uncertainties in cluster masses are currently the dominant systematic affecting cluster abundance constraints on cosmology. To date, however, the CMB cluster lensing signal remains undetected because of its small magnitude and angular size. In this thesis, we develop a maximum likelihood approach to extracting the signal from CMB temperature data. We validate the technique by applying it to mock data designed to replicate as closely as possible real data from the South Pole Telescope’s (SPT) Sunyaev-Zel’dovich (SZ) survey: the effects of the SPT beam, transfer function, instrumental noise and cluster selection are incorporated. We consider the effects of foreground emission on the analysis and show that uncertainty in amount of foreground lensing results in a small systematic error on the lensing constraints. Additionally, we show that if unaccounted for, the SZ effect leads to unacceptably large biases on the lensing constraints and develop an approach for removing SZ contamination. The results of the mock analysis presented here suggest that a 4σ first detection of the cluster lensing effect can be achieved with current SPT-SZ data.

  15. Influence of co-payment levels on patient and surgeon acceptance of advanced technology intraocular lenses.

    Science.gov (United States)

    Carones, Francesco; Knorz, Michael C; Jackson, Daniel; Samiian, Ali

    2014-04-01

    To investigate patients' willingness to pay for advanced technology intraocular lenses and surgeons' willingness to recommend them. In this study, 370 cataract surgeons and 700 patients undergoing cataract surgery from seven countries underwent online interviews in which they were shown unbranded profiles of three advanced technology intraocular lenses (ie, biconvex toric aspheric optic, symmetric biconvex diffractive optic, and biconvex diffractive aspheric toric) and asked to indicate their willingness to accept (for patients) or suggest (for surgeons) each lens. Acceptance was assessed assuming there was either no co-payment or co-payments of €500 to €1,500 +15%. All three lenses were widely accepted by patients, with 68% to 99% indicating acceptance when there was no co-payment. In contrast, surgeons' willingness to suggest them was markedly lower (20% to 43%). Both patients' acceptance of the lenses and surgeons' willingness to suggest them decreased with increasing co-payment levels to 19% to 74% (patients) and 5% to 31% (surgeons) at the highest co-payment levels. There is a marked discrepancy between patients' acceptance of the three lenses and surgeons' willingness to suggest them. Although patients' acceptance is high, it decreases with increasing out-of-pocket expenditure. Manufacturers should communicate the relative benefits and costs of their lenses to both surgeons and patients. Copyright 2014, SLACK Incorporated.

  16. Parent, Teacher, and Student Perspectives on How Corrective Lenses Improve Child Wellbeing and School Function.

    Science.gov (United States)

    Dudovitz, Rebecca N; Izadpanah, Nilufar; Chung, Paul J; Slusser, Wendelin

    2016-05-01

    Up to 20 % of school-age children have a vision problem identifiable by screening, over 80 % of which can be corrected with glasses. While vision problems are associated with poor school performance, few studies describe whether and how corrective lenses affect academic achievement and health. Further, there are virtually no studies exploring how children with correctable visual deficits, their parents, and teachers perceive the connection between vision care and school function. We conducted a qualitative evaluation of Vision to Learn (VTL), a school-based program providing free corrective lenses to low-income students in Los Angeles. Nine focus groups with students, parents, and teachers from three schools served by VTL explored the relationships between poor vision, receipt of corrective lenses, and school performance and health. Twenty parents, 25 teachers, and 21 students from three elementary schools participated. Participants described how uncorrected visual deficits reduced students' focus, perseverance, and class participation, affecting academic functioning and psychosocial stress; how receiving corrective lenses improved classroom attention, task persistence, and willingness to practice academic skills; and how serving students in school rather than in clinics increased both access to and use of corrective lenses. for Practice Corrective lenses may positively impact families, teachers, and students coping with visual deficits by improving school function and psychosocial wellbeing. Practices that increase ownership and use of glasses, such as serving students in school, may significantly improve both child health and academic performance.

  17. Ability of silver-impregnated contact lenses to control microbial growth and colonisation

    Science.gov (United States)

    Willcox, Mark D.P.; Hume, Emma B.H.; Vijay, Ajay K.; Petcavich, Robert

    2010-01-01

    Purpose To examine the ability of silver nano-particles to prevent the growth of Pseudomonas aeruginosa and Staphylococcus aureus in solution or when adsorbed into contact lenses. To examine the ability of silver nano-particles to prevent the growth of Acanthamoeba castellanii. Methods Etafilcon A lenses were soaked in various concentrations of silver nano-particles. Bacterial cells were then exposed to these lenses, and numbers of viable cells on lens surface or in solution compared to etafilcon A lenses not soaked in silver. Acanthamoeba trophozoites were exposed to silver nano-particles and their ability to form tracks was examined. Results Silver nano-particle containing lenses reduced bacterial viability and adhesion. There was a dose-dependent response curve, with 10 ppm or 20 ppm silver showing > 5 log reduction in bacterial viability in solution or on the lens surface. For Acanthamoeba, 20 ppm silver reduced the ability to form tracks by approximately 1 log unit. Conclusions Silver nanoparticles are effective antimicrobial agents, and can reduce the ability of viable bacterial cells to colonise contact lenses once incorporated into the lens.

  18. On Using a Space Telescope to Detect Weak-lensing Shear

    Science.gov (United States)

    Tung, Nathan; Wright, Edward

    2017-11-01

    Ignoring redshift dependence, the statistical performance of a weak-lensing survey is set by two numbers: the effective shape noise of the sources, which includes the intrinsic ellipticity dispersion and the measurement noise, and the density of sources that are useful for weak-lensing measurements. In this paper, we provide some general guidance for weak-lensing shear measurements from a “generic” space telescope by looking for the optimum wavelength bands to maximize the galaxy flux signal-to-noise ratio (S/N) and minimize ellipticity measurement error. We also calculate an effective galaxy number per square degree across different wavelength bands, taking into account the density of sources that are useful for weak-lensing measurements and the effective shape noise of sources. Galaxy data collected from the ultra-deep UltraVISTA Ks-selected and R-selected photometric catalogs (Muzzin et al. 2013) are fitted to radially symmetric Sérsic galaxy light profiles. The Sérsic galaxy profiles are then stretched to impose an artificial weak-lensing shear, and then convolved with a pure Airy Disk PSF to simulate imaging of weak gravitationally lensed galaxies from a hypothetical diffraction-limited space telescope. For our model calculations and sets of galaxies, our results show that the peak in the average galaxy flux S/N, the minimum average ellipticity measurement error, and the highest effective galaxy number counts all lie around the K-band near 2.2 μm.

  19. Ultraviolet (UV) transmittance characteristics of daily disposable and silicone hydrogel contact lenses.

    Science.gov (United States)

    Moore, Linda; Ferreira, Jannie T

    2006-07-01

    The ultraviolet (UV) transmittance spectra of daily wear hydrogel and disposable silicone hydrogel contact lenses were measured. Average transmittance percentages were calculated for each lens for the entire UV spectrum and individually for the UVC, UVB and UVA portions of the spectrum. The significance of the differences in transmittance spectra obtained for the lenses was analysed using a one-way ANOVA planned comparisons test (alpha=0.05). The transmittance data were then used to calculate a UV protection factor (PF) for each contact lens brand tested. The PFs for 1-DAY ACUVUE MOIST (6.22), ACUVUE ADVANCE (10.02) and ACUVUE OASYS (11.96) contact lenses show that these contact lenses have superior UV-blocking capabilities. The PFs for Focus DAILIES (1.79), SofLens 1-day disposables (1.72), NIGHT & DAY (1.84), O2 Optix (1.99) and Purevision (2.62) show that these contact lenses posses more modest UV-blocking characteristics. This paper reviews the importance of protection of the anterior ocular surface from UV damage and quantifies the protection afforded by selected commercially available disposable contact lenses.

  20. Strongly lensed gravitational waves and electromagnetic signals as powerful cosmic rulers

    Science.gov (United States)

    Wei, Jun-Jie; Wu, Xue-Feng

    2017-12-01

    In this paper, we discuss the possibility of using strongly lensed gravitational waves (GWs) and their electromagnetic (EM) counterparts as powerful cosmic rulers. In the EM domain, it has been suggested that joint observations of the time delay (Δτ) between lensed quasar images and the velocity dispersion (σ) of the lensing galaxy (i.e. the combination Δτ/σ2) are able to constrain the cosmological parameters more strongly than Δτ or σ2 separately. Here, for the first time, we propose that this Δτ/σ2 method can be applied to the strongly lensed systems observed in both GW and EM windows. Combining the redshifts, images and σ observed in the EM domain with the very precise Δτ derived from lensed GW signals, we expect that accurate multimessenger cosmology can be achieved in the era of third-generation GW detectors. Comparing with the constraints from the Δτ method, we prove that using Δτ/σ2 can improve the discrimination between cosmological models. Furthermore, we demonstrate that with ∼50 strongly lensed GW-EM systems, we can reach a constraint on the dark energy equation of state w comparable to the 580 Union2.1 Type Ia supernovae data. Much more stringent constraints on w can be obtained when combining the Δτ and Δτ/σ2 methods.