WorldWideScience

Sample records for lens solutions sterility

  1. Sterilization potential of contact lens solutions

    Directory of Open Access Journals (Sweden)

    Dada Vijay

    1988-01-01

    Full Text Available In a dynamic field of Contact Lens Solutions maintenance of high standards of anti-microbial activity is a must Resterilization Activity Time′ is a universally accepted yardstick for such an evaluation. In this study eight brands of indigenous popular solutions alongwith two FDA approved solutions were tested for their sterilization efficacy: Standardized suspensions of Pseudomonas aeruginosa, Staphylococcus aureus, Candida albicans and Aspergillus fumigatus were used for the purpose. It was observed that the contact lens solutions available ir, the domestic market were not upto the mark Suggestions for improvement have also been made.

  2. Sterilization potential of contact lens solutions

    OpenAIRE

    Dada Vijay; Mehta Manoj

    1988-01-01

    In a dynamic field of Contact Lens Solutions maintenance of high standards of anti-microbial activity is a must Resterilization Activity Time′ is a universally accepted yardstick for such an evaluation. In this study eight brands of indigenous popular solutions alongwith two FDA approved solutions were tested for their sterilization efficacy: Standardized suspensions of Pseudomonas aeruginosa, Staphylococcus aureus, Candida albicans and Aspergillus fumigatus were used for the purpose. ...

  3. 21 CFR 800.10 - Contact lens solutions; sterility.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Contact lens solutions; sterility. 800.10 Section...) MEDICAL DEVICES GENERAL Requirements for Specific Medical Devices § 800.10 Contact lens solutions... ophthalmic use, including contact lens solutions, should be sterile. It is further evident that such...

  4. Sterility and the disinfection potential of Indian contact lens solutions

    Directory of Open Access Journals (Sweden)

    Gopinathan Usha

    1994-01-01

    Full Text Available Ocular infection associated with microbial contamination of contact lens care products is a major problem in contact lens wearers. The sterility and the antimicrobial activity of contact lens care systems reflect their suitability for disinfection of contact lenses. These factors remain to be evaluated for the various newer contact lens care products manufactured in India. In this study, 35 bottles of contact lens solutions marketed by different manufacturing units in India were tested for sterility. Seven solutions were tested for antimicrobial effectiveness employing the D value method of analysis. The D value is defined as the time required to reduce a population of organisms by 90% (one log unit. A standard inoculum of the ocular isolates of Staphylococcus aureus, Pseudomonas aeruginosa, Serratia marcescens, Aspergillus fumigatus, Fusarium solani, and Acanthamoeba castellanii were used as challenge organisms. Bacterial contamination was detected in 20 (57.1% solution bottles and none yielded fungus or Acanthamoeba. Pseudomonas species were the most commonly encountered contaminant (11/20; 55%. Only sterile solutions were analyzed for antimicrobial activity. D values ranging between 12 and 20 minutes were demonstrated by six of the seven solutions against bacterial challenge. Good antifungal activity was noticed in five solutions against Fusarium solani though results varied with Aspergillus flavus and Candida albicans. All solutions were adequately effective against Acanthamoeba.

  5. 21 CFR 522.1484 - Neomycin sulfate sterile solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Neomycin sulfate sterile solution. 522.1484... § 522.1484 Neomycin sulfate sterile solution. (a) Specifications. Each milliliter of sterile aqueous solution contains 50 milligrams of neomycin sulfate (equivalent to 35 milligrams of neomycin base).1 1...

  6. 21 CFR 522.82 - Aminopropazine fumarate sterile solution injection.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Aminopropazine fumarate sterile solution injection... ANIMAL DRUGS § 522.82 Aminopropazine fumarate sterile solution injection. (a) Specifications. Each milliliter of aminopropazine fumarate sterile aqueous solution, veterinary, contains aminopropazine fumarate...

  7. Sterilization of solutions for parenterals products. Problem analysis

    Directory of Open Access Journals (Sweden)

    Yanelys Montes-González

    2017-09-01

    Full Text Available The solutions for the formulation of parenteral products must be sterile before the aseptic formulation process. For this reason, different methods of sterilization referred in the literature are analyzed. Thermodynamic criteria that rule the sterilization are presented. Furthermore, previous experiences in the sterilization of solutions for the formulation of parental products in an autoclave are analyzed, that take large time of processing and only low volumes of solution can be handled. Using jacketed stirred tanks for the sterilization may solve the problem and, therefore, criteria for the design of the later that allow to process high volumes of solution for the formulation of parenteral products are shown.

  8. Survival of Acanthamoeba in contact lens rinse solutions.

    Science.gov (United States)

    Nauheim, R C; Brockman, R J; Stopak, S S; Turgeon, P W; Keleti, G; Roat, M I; Thoft, R A

    1990-10-01

    Acanthamoeba may cause a severe keratitis in contact lens wearers. Since most sterilization techniques require rinsing the lenses prior to insertion, contaminated solutions represent a potential vector for transmission of Acanthamoeba. The ability of rinse solutions to sustain an inoculum of Acanthamoeba polyphaga was investigated. A. polyphaga was exposed to 0.1% benzalkonium chloride, 0.001% thimerosal/0.1% edetate disodium, 0.1% edetate disodium, saline, tap water, and distilled water. The status of the organism was evaluated with direct microscopic counts and cultures to confirm viability. Incubation with 0.1% edetate disodium, saline, tap water, and distilled water resulted in the maintenance of reduced populations of viable organisms for 7 days. Benzalkonium chloride preserved saline and solutions containing thimerosal with edetate rendered the Acanthamoeba nonviable.

  9. [Acanthamoeba isolation from contact lens solution of contact lens wearers without keratitis].

    Science.gov (United States)

    Watanabe, R; Ishibashi, Y; Hommura, S; Ishii, K

    1994-05-01

    Acanthamoeba keratitis seems to be associated with wearing contact lenses. As controls, we surveyed contact lens wearers without keratitis. Contact lens solutions of 93 persons were examined in order to identify risk factors for contamination by Acanthamoeba. Therefore, the contact lens disinfection system and storage schedules were studied in each case. Acanthamoeba organisms were isolated from 4 specimens (4.3%). The incidence of Acanthamoeba was higher in specimens of soft contact lens solution than in those of hard contact lens solution, and all the Acanthamoeba positive cases had been using tap water.

  10. Effect of microwave treatment to acanthamoeba: a possibility of contact lens storage case sterilization?

    International Nuclear Information System (INIS)

    Hiti, K.; Faschinger, C.; Haller-Schober, E.M.; Walochnik, J.; Aspoeck, H.; Hiti, B.

    2003-01-01

    Microbially contaminated contact lens storage cases are considered to be a predisposing risk factor for Acanthamoeba keratitis. What kind of effect does microwave irradiation have on contact lens cases contaminated with Acanthamoeba cysts and trophozoites? Different types of contact lens cases were contaminated with trophozoites and cysts of three different Acanthamoeba species (A. hatchetti, A. castellanii, A. comandoni) and exposed to microwave irradiation for 3, 5 and 8 minutes respectively. One of the three test series was run with dehydrated cysts. After an irradiation period of 3 minutes under humid conditions cysts and trophozoites of all three strains were completely destroyed. Dehydrated cysts of A. hatchetti and A. castellanii were not killed by irradiation. There were no negative effects of irradiation on the contact lens cases themselves. Acanthamoeba cysts and trophozoites are effectively killed by microwave irradiation on condition that irradiation takes place in humid conditions. This can be easily achieved by filling the contact lens storage cases with tap water. We recommend microwave irradiation as a cheap and save method for the sterilization of contact lens cases in order to avoid a possible Acanthamoeba infection of the eye. (author)

  11. 21 CFR 522.380 - Chloral hydrate, pentobarbital, and magnesium sulfate sterile aqueous solution.

    Science.gov (United States)

    2010-04-01

    ... sulfate sterile aqueous solution. 522.380 Section 522.380 Food and Drugs FOOD AND DRUG ADMINISTRATION... sterile aqueous solution. (a) [Reserved] (b)(1) Specifications. Chloral hydrate, pentobarbital, and magnesium sulfate sterile aqueous solution contains 42.5 milligrams of chloral hydrate, 8.86 milligrams of...

  12. Repertoire of free-living protozoa in contact lens solutions.

    Science.gov (United States)

    Bouchoucha, Ibtissem; Aziz, Aurore; Hoffart, Louis; Drancourt, Michel

    2016-10-29

    The repertoire of free-living protozoa in contact lens solutions is poorly known despite the fact that such protozoa may act as direct pathogens and may harbor intra-cellular pathogens. Between 2009 and 2014, the contact lens solutions collected from patients presenting at our Ophthalmology Department for clinically suspected keratitis, were cultured on non-nutrient agar examined by microscope for the presence of free-living protozoa. All protozoa were identified by 18S rRNA gene sequencing. A total of 20 of 233 (8.6 %) contact lens solution specimens collected from 16 patients were cultured. Acanthamoeba amoeba in 16 solutions (80 %) collected from 12 patients and Colpoda steini, Cercozoa sp., Protostelium sp. and a eukaryotic more closely related to Vermamoeba sp., were each isolated in one solution. Cercozoa sp., Colpoda sp., Protostelium sp. and Vermamoeba sp. are reported for the first time as contaminating contact lens solutions. The repertoire of protozoa in contact lens solutions is larger than previously known.

  13. Susceptibility of Acanthamoeba castellanii to contact lens disinfecting solutions.

    Science.gov (United States)

    Zanetti, S; Fiori, P L; Pinna, A; Usai, S; Carta, F; Fadda, G

    1995-01-01

    A corneal isolate of Acanthamoeba castellanii was exposed to commercial contact lens disinfecting solutions containing hydrogen peroxide, benzalkonium chloride, polyaminopropyl biguanide, polyquaternium 1, and chlorhexidine-thimerosal. The minimum trophozoite amebicidal concentration and exposure times required to kill trophozoites and cysts were determined. Solutions containing hydrogen peroxide or chlorhexidine-thimerosal were active against both trophozoites and cysts. The benzalkonium chloride-based solution was effective only against trophozoites. Solutions containing polyaminopropyl biguanide or polyquaternium 1 were completely ineffective. The need for adequate exposure times must be stressed. PMID:7492111

  14. 21 CFR 800.12 - Contact lens solutions and tablets; tamper-resistant packaging.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Contact lens solutions and tablets; tamper....12 Contact lens solutions and tablets; tamper-resistant packaging. (a) General. Unless contact lens solutions used, for example, to clean, disinfect, wet, lubricate, rinse, soak, or store contact lenses and...

  15. Bacterial transmission from lens storage cases to contact lenses - Effects of lens care solutions and silver impregnation of cases

    NARCIS (Netherlands)

    Vermeltfoort, Pit B. J.; Hooymans, Johanna M. M.; Busscher, Henk J.; van der Mei, Henny C.

    2008-01-01

    The killing efficacies of multipurpose lens care solutions on planktonic and biofilm bacteria grown in polypropylene contact lens storage cases with and without silver impregnation and effects on bacterial transmission from storage cases to silicone hydrogel contact lenses were investigated. For

  16. Bacterial and fungal biofilm formation on contact lenses and their susceptibility to lens care solutions

    Directory of Open Access Journals (Sweden)

    Siddharth Kackar

    2017-01-01

    Full Text Available Background: Microbial biofilm formation on contact lenses and lens storage cases may be a risk factor for contact lens-associated corneal infections. Various types of contact lens care solutions are used to reduce microbial growths on lenses. Objectives: The present study aimed at comparing the growths of biofilms on the different contact lenses and lens cases. The study also aimed at determining the effect of lens care solutions and bacteriophage on these biofilms. Materials and Methods: One type of hard lens and two types of soft lenses were used for the study. The organisms used were Staphylococcus aureus ATCC 25923, Pseudomonas aeruginosa ATCC 27853, Candida albicans ATCC 60193 and Escherichia coli ATCC 25922. Biofilm production was performed by modified O'Toole and Kolter method and effect of lens cleaning solutions and a crude coliphage on biofilms was also studied. Results were visualised using scanning electron microscopy and quantitated by colony counting method and spectrophotometric measurement of optical density (OD. Statistical analysis was done by SPSS 11.5, Kruskal–Wallis test and Chi-square test. Results: Soft lens cleaning solutions had a significant inhibitory effect (P = 0.020 on biofilm formation on soft lenses and also lens cases (P < 0.001. Soft lens cleaning solution 2 was more efficient than solution 1. However, no such inhibitory effect was observed with regard to hard lens cleaning solution, but for a significant reduction in the OD values (P < 0.001. There was no significant inhibitory effect by bacteriophages. Conclusion: This study showed the importance of selecting the appropriate lens cleaning solution to prevent biofilm production on contact lenses.

  17. Evaluation for sterility of four crystalloid solutions used in ...

    African Journals Online (AJOL)

    Pre and post preservation, a loop-full of each solution was cultured on freshly prepared two general purpose media (Blood and nutrient agar) and one selective medium (MacConkey agar). They were incubated at 37 0C for 48 hours after which they were examined for bacterial growth. Histological studies of the preserved ...

  18. Theoretical approach to the destruction or sterilization of drugs in aqueous solution

    International Nuclear Information System (INIS)

    Slegers, Catherine; Tilquin, Bernard

    2005-01-01

    Two novel applications in the radiation processing of aqueous solutions of drugs are the sterilization of injectable drugs and the decontamination of hospital wastewaters by ionizing radiation. The parameters influencing the destruction of the drug in aqueous solutions are studied with a computer simulation program. This theoretical approach has revealed that the dose rate is the most important parameter that can be easily varied in order to optimize the destruction or the protection of the drug

  19. An investigation into the stability and sterility of citric acid solutions used for cough reflex testing.

    Science.gov (United States)

    Falconer, James R; Wu, Zimei; Lau, Hugo; Suen, Joanna; Wang, Lucy; Pottinger, Sarah; Lee, Elaine; Alazawi, Nawar; Kallesen, Molly; Gargiulo, Derryn A; Swift, Simon; Svirskis, Darren

    2014-10-01

    Citric acid is used in cough reflex testing in clinical and research settings to assess reflexive cough in patients at risk of swallowing disorders. To address a lack of knowledge in this area, this study investigated the stability and sterility of citric acid solutions. Triplicate solutions of citric acid (0.8 M) in isotonic saline were stored at 4 ± 2 °C for up to 28 days and analysed by high-performance liquid chromatography. Microbiological sterility of freshly prepared samples and bulk samples previously used for 2 weeks within the hospital was determined using a pour plate technique. Microbial survival in citric acid was determined by inoculating Staphylococcus aureus, Escherichia coli, or Candida albicans into citric acid solution and monitoring the number of colony-forming units/mL over 40 min. Citric acid solutions remained stable at 4 °C for 28 days (98.4 ± 1.8 % remained). The freshly prepared and clinical samples tested were sterile. However, viability studies revealed that citric acid solution allows for the survival of C. albicans but not for S. aureus or E. coli. The microbial survival study showed that citric acid kills S. aureus and E. coli but has no marked effect on C. albicans after 40 min. Citric acid samples at 0.8 M remained stable over the 4-week testing period, with viable microbial cells absent from samples tested. However, C. albicans has the ability to survive in citric acid solution if inadvertently introduced in practice. For this reason, in clinical and research practice it is suggested to use single-use aliquots prepared aseptically which can be stored for up to 28 days at 4 °C.

  20. Tap water versus sterile saline solution in the colonisation of skin wounds.

    Science.gov (United States)

    Resende, Margarida Mc; Rocha, Cleber A; Corrêa, Nely Fm; Veiga, Renato Rg; Passos, Sandro Jf; Novo, Neil F; Juliano, Yara; Damasceno, Carlos Av

    2016-08-01

    Irrigating wounds with tap water does not increase colonisation, but controlled studies are required for further evidence. Microbial colonisation was assessed in skin wounds, before and after irrigation with tap water, and was compared with irrigation using 0·9% sodium chloride sterile solution. The study included 120 subjects with chronic, traumatic, vascular, pressure or neuropathic wounds. A total of 60 wounds were randomly assigned to be irrigated with tap water (tap water group) and another 60 to be irrigated with 0·9% sodium chloride sterile solution (saline group), at a pressure of 0·46-0·54 PSI. Samples were collected from the centre of each wound using Levine's technique, before and after irrigation, and cultivated in thioglycollate, hypertonic mannitol agar, eosin methylene blue (EMB) agar, blood agar and Sabouraud agar at 37°C for 72 hours. There was concordance (kappa test) and discordance (McNemar test) regarding the count of positive and/or negative samples before and after irrigation in each group. The proportion of reduction of positive samples was similar for both groups in all cultures. Colony-forming unit count before and after irrigation was similar in both groups and in all cultures, except for the culture in hypertonic mannitol agar from the tap water group, for which the count was lower after irrigation (Wilcoxon z = 2·05, P = 0·041). It is concluded that skin wound irrigation with tap water leads to further reduction of Gram-positive bacteria compared with 0·9% sodium chloride sterile solution, with no difference in colonisation of haemolytic bacteria, Gram-negative bacteria and fungi. © 2015 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  1. Adhesion of Pseudomonas aeruginosa to contact lenses after exposure to multi-purpose lens care solutions

    NARCIS (Netherlands)

    Bruinsma, GM; Van der Mei, HC; Busscher, HJ; de Vries, Jacob

    2001-01-01

    Elemental surface compositions of contact lenses were measured after exposure to different lens care solutions (LCS) using X-ray photoelectron spectroscopy and were related to adhesion and detachment of Pseudomonas aeruginosa. Etafilcon A and polymacon contact lenses, prior to and after exposure to

  2. Susceptibility of Acanthamoeba to multipurpose lens-cleaning solutions.

    Science.gov (United States)

    de Aguiar, Ana Paula Costa; de Oliveira Silveira, Caroline; Todero Winck, Mari Aline; Rott, Marilise Brittes

    2013-09-01

    The present study investigated the susceptibility of Acanthamoeba spp. trophozoites to two multipurpose systems for cleaning and maintenance of contact lenses. Three strains of trophozoites from the ATCC (A. castellani T4, A. castellani Neff, and A. polyphaga) and two Acanthamoeba isolates obtained from swimming pools (PT5 and PO1) were placed in monoxenic culture. To test their survival in cleaning solutions for contact lenses, the trophozoites were exposed for 4 and 24 h to two multipurpose solutions (A and B), and were then inoculated into a new monoxenic culture. Amoebic growth on the plates was observed after 72 h of incubation. Trophozoites from all three ATCC strains and one isolate from a swimming pool (PO1) grew in all plates after 4 h of exposure to solutions A and B. After 24 h, the ATCC strains and the PO1 isolate showed growth in most of the plates treated. Only the PT5 isolate showed susceptibility to both solutions over the time intervals tested. The two solutions were not completely effective against most strains and isolates over the time intervals tested. These results are important, since species of Acanthamoeba are widely distributed in the environment and are potential agents of eye pathologies.

  3. Acanthamoeba encystment: multifactorial effects of buffers, biocides, and demulcents present in contact lens care solutions

    Directory of Open Access Journals (Sweden)

    Kovacs CJ

    2015-10-01

    Full Text Available Christopher J Kovacs, Shawn C Lynch, Marjorie J Rah, Kimberly A Millard, Timothy W Morris Bausch & Lomb Incorporated, Rochester, NY, USA Purpose: To determine whether agents which are purportedly capable of inducing encystment of Acanthamoeba can recapitulate the signal when tested in differing formulations. Methods: In accordance with the International Standard ISO 19045, Acanthamoeba castellanii ATCC 50370 trophozoites were cultured in antibiotic-free axenic medium, treated with test solutions, and encystment rates plus viability were measured via bright field and fluorescent microscopy. Test solutions included phosphate-buffered saline (PBS, borate-buffered saline, biguanide- and hydrogen peroxide (H2O2-based biocides, propylene glycol (PG and povidone (POV ophthalmic demulcents, and one-step H2O2-based contact lens disinfection systems. Results: Only PBS solutions with 0.25 ppm polyaminopropyl biguanide (PAPB and increasing concentrations of PG and POV stimulated A. castellanii encystment in a dose-dependent manner, whereas PBS solutions containing 3% H2O2 and increasing concentrations of PG and POV did not stimulate encystment. Borate-buffered saline and PBS/citrate solutions containing PG also did not stimulate encystment. In addition, no encystment was observed after 24 hours, 7 days, or 14 days of exposures of trophozoites to one-step H2O2 contact lens disinfection products or related solutions. Conclusion: The lack of any encystment observed when trophozoites were treated with existing or new one-step H2O2 contact lens care products, as well as when trophozoites were exposed to various related test solutions, confirms that Acanthamoeba encystment is a complex process which depends upon simultaneous contributions of multiple factors including buffers, biocides, and demulcents. Keywords: propylene glycol, contact lens care system, hydrogen peroxide disinfecting solution

  4. Compliance among soft contact lens wearers.

    Science.gov (United States)

    Kuzman, Tomislav; Kutija, Marija Barisić; Masnec, Sanja; Jandroković, Sonja; Mrazovac, Danijela; Jurisić, Darija; Skegro, Ivan; Kalauz, Miro; Kordić, Rajko

    2014-12-01

    Contact lens compliance is proven to be crucial for preventing lens wear-related complications because of the interdependence of the steps in lens care regime and their influence on lens system microbial contamination. Awareness of the patients' lens handling compliance as well as correct recognition of non-compliant behaviours is the basis for creating more targeted strategies for patient education. The aim of this study was to investigate compliance among soft contact lens (SCL) wearers in different aspects of lens care handling and wearing habits. In our research 50 asymptomatic lens wearers filled out a questionnaire containing demographic data, lens type, hygiene and wearing habits, lenses and lens care system replacement schedule and self-evaluation of contact lens handling hygiene. We established criteria of compliance according to available manufacturer's recommendations, prior literature and our clinical experience. Only 2 (4%) of patients were fully compliant SCL wearers. The most common non-compliant behaviours were insufficient lens solution soaking time (62%), followed by failure to daily exchange lens case solution and showering while wearing lenses. 44% of patients reported storing lenses in saline solution. Mean lens storage case replacement was 3.6 months, with up to 78% patients replacing lens case at least once in 3 months. Average grade in self evaluating level of compliance was very good (4 +/- 0.78) (from 1-poor level of hygiene to 5-great level of hygiene). Lens wearers who reported excessive daily lens wear and more than 10 years of lens wearing experience were also found to be less compliant with other lens system care procedures. (t = -2.99, df=47, p lens system maintenance steps. Most common non-compliant behaviours were the ones that are crucial for maintaining lens sterility and preventing infection. Despite the low objective compliance rate, self grading was relatively high. Therefore, these results indicate the need for patient

  5. In vitro effects of selected contact lens care solutions on Acanthamoeba castellanii strains in Poland.

    Science.gov (United States)

    Padzik, Marcin; Chomicz, Lidia; Szaflik, Jacek P; Chruścikowska, Agnieszka; Perkowski, Konrad; Szaflik, Jerzy

    2014-11-01

    Free-living, cosmopolitan amoebae of the Acanthamoeba genus may be the causative agents of Acanthamoeba keratitis (AK) - a progressive, vision-threatening infection of the human cornea described particularly among contact lens wearers. Use of contact lens care solutions, effective against these organisms, is important in preventing AK infections. 3 different strains of Acanthamoeba castellanii of the T4 genotype (Neff strain and two others, isolated from patients with AK) were exposed to 4 selected multipurpose contact lens care solutions available in Poland: Ciba Vision AoSept Plus, Bausch & Lomb ReNu MultiPlus, Alcon Opti-Free, Ciba Vision Solo Care Aqua. No amoebicidal effect was observed. The strongest amoebostatic effect was visible after 24h of exposition to Opti-Free and ReNu solution and associated with percentage increase of rounded, motionless forms. This is significantly longer than minimum disinfection time recommended by manufacturers of all tested multipurpose solutions. Surprisingly, no clear induction of the encystation process was observed. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Efficacy of Korean Multipurpose Contact Lens Disinfecting Solutions againstAcanthamoeba castellanii.

    Science.gov (United States)

    Moon, Eun-Kyung; Park, Hye-Ryun; Quan, Fu-Shi; Kong, Hyun-Hee

    2016-12-01

    Acanthamoeba keratitis has been increasing in recent years. Main risk factors are contact lens wear and their cleaning solutions. Most contact lens wearers use multipurpose disinfecting solutions (MPDS) for cleansing and disinfecting microorganisms because of its convenience. We determined amoebicidal effects of MPDS made in Korea and their cytotoxicity on human corneal epithelium cells. Fifteen commercial MPDS (A to O) were tested for their amoebicidal effects on Acanthamoeba castellanii trophozoites and cysts by using a most probable number (MPN) technique. Among them, 7 kinds of MPDS showed little or no amoebicidal effects for 24 hr exposure. Solutions A, B, G, H, L, and O showed positive amoebicidal effects, and solutions M and N killed almost all trophozoites and cysts after 24 hr exposure. However, 50%-N solution showed 56% cytotoxicity on human corneal epithelial cells within 4 hr exposure, and 50%-O solution also showed 62% cytotoxicity on human cells within 4 hr exposure. Solution A did not show any cytotoxicity on human cells. These results revealed that most MPDS made in Korea were ineffective to kill Acanthamoeba . The solutions having amoebicidal activity also showed high levels of cytotoxicity on human corneal epithelial cells. New formulations for improved MPDS that are amoebicidal but safe for host cells are needed to prevent Acanthamoeba keratitis.

  7. Inefficacy of marketed contact lens disinfection solutions against keratitis-causing Acanthamoeba castellanii belonging to the T4 genotype.

    Science.gov (United States)

    Lakhundi, Sahreena; Khan, Naveed Ahmed; Siddiqui, Ruqaiyyah

    2014-06-01

    The aim of this study was to assess the anti-amoebic effects of marketed contact lens disinfecting solutions. Using amoebistatic, amoebicidal, and cysticidal assays, nine different contact lens solutions were tested including: ReNu MultiPlus, DuraPlus, Ultimate Plus, OptiFree Replenish, OptiFree Express, Kontex Clean, Kontex Normal, Kontex Multisol extra+, Kontex Soak. In vitro growth inhibition (amoebistatic) assays were performed by incubating Acanthamoeba castellanii with aforementioned contact lens disinfection solutions as per manufacturer's instructions in the growth medium for up to 48h at 30°C. To determine amoebicidal and cysticidal effects, amoebae were incubated with contact lens solutions in phosphate buffered saline for 24h and viability was determined by haemocytometer counting as well as re-inoculating them in the growth medium. For controls, solutions were tested against bacterial corneal pathogen, Pseudomonas aeruginosa, as well as amoebae were incubated with the solvent alone. Of the nine contact lens solutions tested, none of them showed potent amoebicidal effects. Only DuraPlus and OptiFree Replenish exhibited trophozoite lysis of 85.3% and 73.7% respectively. In contrast, all contact lens disinfection solutions except Kontex Clean, Kontex Normal, Kontex Multisol extra+, tested showed amoebistatic effects. Importantly, none of the contact lens disinfection solutions exhibited cysticidal effects using qualitative assays, i.e., cysts treated with aforementioned solutions re-emerged as viable amoebae upon inoculation in the growth medium. However, more than 3-log reduction was observed when ReNu MultiPlus, DuraPlus and OptiFree Express were tested against P. aeruginosa which is in accordance with the ISO Stand-Alone Primary acceptance criteria. These findings are of great concern for contact lens users. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Hard sphere-like glass transition in eye lens α-crystallin solutions.

    Science.gov (United States)

    Foffi, Giuseppe; Savin, Gabriela; Bucciarelli, Saskia; Dorsaz, Nicolas; Thurston, George M; Stradner, Anna; Schurtenberger, Peter

    2014-11-25

    We study the equilibrium liquid structure and dynamics of dilute and concentrated bovine eye lens α-crystallin solutions, using small-angle X-ray scattering, static and dynamic light scattering, viscometry, molecular dynamics simulations, and mode-coupling theory. We find that a polydisperse Percus-Yevick hard-sphere liquid-structure model accurately reproduces both static light scattering data and small-angle X-ray scattering liquid structure data from α-crystallin solutions over an extended range of protein concentrations up to 290 mg/mL or 49% vol fraction and up to ca. 330 mg/mL for static light scattering. The measured dynamic light scattering and viscosity properties are also consistent with those of hard-sphere colloids and show power laws characteristic of an approach toward a glass transition at α-crystallin volume fractions near 58%. Dynamic light scattering at a volume fraction beyond the glass transition indicates formation of an arrested state. We further perform event-driven molecular dynamics simulations of polydisperse hard-sphere systems and use mode-coupling theory to compare the measured dynamic power laws with those of hard-sphere models. The static and dynamic data, simulations, and analysis show that aqueous eye lens α-crystallin solutions exhibit a glass transition at high concentrations that is similar to those found in hard-sphere colloidal systems. The α-crystallin glass transition could have implications for the molecular basis of presbyopia and the kinetics of molecular change during cataractogenesis.

  9. Variation of clearance considering viscosity of the solution used in the reservoir and following scleral lens wear over time.

    Science.gov (United States)

    Courey, Claudine; Michaud, Langis

    2017-08-01

    This study aims to evaluate the settling of a scleral lens and if this process is influenced by the nature of the fluid layer. A prospective, non-randomized control study was performed using an 18mm scleral lens. They were fitted with a central clearance of 400 um at insertion. One eye was randomly assigned to be fitted with a non-preserved gel solution of carboxymethylcellulose, while the other was inserted with non-preserved saline. Measurements of clearance in 3 locations were taken (OCT) at baseline, every 30min up to 1h30 post insertion and every 2h thereafter up to 6h00 of wear. A two-way repeated measure analysis of variance (liquids×times) was used to test central, nasal and temporal fluid thickness. Following 6h of wear, the 18mm lens had a mean central settling of 70.0±9.8μm, 36.7±9.8μm of which occurred within the first 30min of wear. There was no significant difference between lenses filled with non-preserved saline to those with non-preserved gel. However, a paired comparison concluded to a significant difference between mean nasal settling (41.4μm) and temporal settling (20.4μm). With respect to the lens studied, current results suggest that practitioners can evaluate the lens 30min post insertion and can estimate the amount of fluid that will remain after lens stabilization by doubling the value obtained initially. The use of non-preserved saline or non-preserved more viscous solution to fill the lens does not influence its settling. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  10. Gamma and x radiation and thermal neutrons effects in lens solutions and the relation with proteins concentration

    International Nuclear Information System (INIS)

    Ramirez A, M.; Alarcon C, A.

    1996-01-01

    Radiation effects have been studied irradiating porcine lens solutions with doses which range between 52 Gy to 1042 Gy in the case of x-rays (30 kVp), 631 Gy to 4001 Gy in the case of 60 Co gamma rays and 314 Gy to 7596 Gy for thermal neutrons. The optics density time variation of solutions was determined using a Spectronic-501 spectrophotometer, and with this data an equation which describes the behavior in the mentioned cases was found. A phenomenological model is postulated which connects the optical time variation density increment macroscopic effect with proteins concentration in the crystalline lens obtaining relative biological effectiveness using the supra-molecular aggregate formation due to the denaturalization and destruction of lens proteins by radiation criteria. (authors). 5 refs., 3 figs

  11. Irrigation of continent catheterizable ileal pouches: tap water can replace sterile solutions because it is safe, easy, and economical.

    Science.gov (United States)

    Birkhäuser, Frédéric D; Zehnder, Pascal; Roth, Beat; Schürch, Leander; Ochsner, Katharina; Willener, Rita; Thalmann, George N; Burkhard, Fiona C; Studer, Urs E

    2011-04-01

    Continent catheterizable ileal pouches require regular irrigations to reduce the risk of bacteriuria and urinary tract infections (UTIs). Our aim was to compare the UTI rate, patient friendliness, and costs of standard sterile irrigation versus irrigation with tap water. Twenty-three patients participated in a prospective randomized two-arm crossover single-center trial. Aseptic intermittent self-catheterization (ISC) combined with sterile sodium chloride (NaCl) 0.9% irrigation was compared with clean ISC and irrigation with tap water (H(2)O) during two study periods of 90 d each. Patients underwent daily pouch irrigations with NaCl 0.9% solution or tap water. Urine nitrite dipstick tests were evaluated daily; urine culture (UC) and patient friendliness were evaluated monthly. Costs were documented. A total of 3916 study days with nitrite testing and irrigation were analyzed, 1876 (48%) in the NaCl arm and 2040 (52%) in the H(2)O arm. In the NaCl arm, 418 study days (22%) with nitrite-positive dipsticks were recorded, 219 d (11%) in the H(2)O arm, significantly fewer (p=0.01). Of the 149 UCs, 96 (64%) were positive, 48 in each arm, revealing a total of 16 different germs. All patients preferred the H(2)O method. Monthly costs were up to 20 times lower in the H(2)O arm. Pouch irrigation with sterile NaCl 0.9% solution and tap water had comparable rates of positive UC. Irrigation with tap water significantly lowered the incidence of nitrite-positive study days and was substantially less costly and more patient friendly than NaCl irrigation. We therefore recommend the use of tap water (or bottled water) instead of sterile NaCl 0.9% solution for daily irrigation of continent catheterizable ileal pouches. Australian New Zealand Clinical Trials Registry, ACTRN12610000618055, http://www.ANZCTR.org.au/ACTRN12610000618055.aspx. Copyright © 2011 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  12. Increase of the radiochemical purity of aqueous solutions of compounds labelled with 131I using a ClAg sterile column

    International Nuclear Information System (INIS)

    Pliego, O.H.; Mitta, A.E.A.

    1980-01-01

    The use of a C1Ag sterile column that may be easily assembled at any nuclear medical center is proposed. The column is easy to handle and allows to obtain aqueous solutions of compounds labelled with radioactive iodine, with a radiochemical purity greater than 99%, conserving pH values, activity concentration, apyretogenia and sterility, the controls of toxicity and presence of heavy metals being negative. (C.A.K) [es

  13. Contact lens care solution killing efficacy against Acanthamoeba castellanii by in vitro testing and live-imaging.

    Science.gov (United States)

    Kolar, Satya Sree N; Manarang, Joseph C; Burns, Alan R; Miller, William L; McDermott, Alison M; Bergmanson, Jan P G

    2015-12-01

    In the past decade there has been an increased incidence of Acanthamoeba keratitis, particularly in contact lens wearers. The aim of this study was to utilize in vitro killing assays and to establish a novel, time-lapse, live-cell imaging methodology to demonstrate the efficacy of contact lens care solutions in eradicating Acanthamoeba castellanii (A. castellanii) trophozoites and cysts. Standard qualitative and quantitative in vitro assays were performed along with novel time-lapse imaging coupled with fluorescent dye staining that signals cell death. Quantitative data obtained demonstrated that 3% non-ophthalmic hydrogen peroxide demonstrated the highest percent killing at 87.4% corresponding to a 4.4 log kill. The other contact lens care solutions which showed a 72.9 to 29.2% killing which was consistent with 4.3-2.8 log reduction in trophozoite viability. Both analytical approaches revealed that polyquaternium/PHMB-based was the least efficacious in terms of trophicidal activity. The cysticidal activity of the solutions was much less than activity against trophozoites and frequently was not detected. Live-imaging provided a novel visual endpoint for characterizing the trophocidal activity of the care solutions. All solutions caused rapid rounding or pseudocyst formation of the trophozoites, reduced motility and the appearance of different morphotypes. Polyquaternium/alexidine-based and peroxide-based lens care system induced the most visible damage indicated by significant accumulation of debris from ruptured cells. Polyquaternium/PHMB-based was the least effective showing rounding of the cells but minimal death. These observations are in keeping with care solution biocides having prominent activity at the plasma membrane of Acanthamoeba. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Tear Lipids Interfacial Rheology: Effect of Lysozyme and Lens Care Solutions

    Science.gov (United States)

    Svitova, Tatyana F.; Lin, Meng C.

    2014-01-01

    Purpose To evaluate the interfacial properties of ex vivo tear lipid multilayers with controlled and varying thickness. The influence of lysozyme and surfactant-containing multi-purpose lens care solutions (MPS) on interfacial rheology of lipids and mixed lipid-protein films were studied. Methods Lipids were extracted from lotrafilcon A lenses worn continuously for 1 month. Interfacial properties of the lipids without and with lysozyme in the aqueous phase were examined using tensiometry and step-strain relaxation. Lipid-lysozyme multilayers were exposed to either diluted Optifree Express (OFX) or Optifree Replenish (OFR) for 30 min, and then MPS was displaced from the bulk phase. Surface tension and rheological parameters before and after MPS exposure were measured and compared. Results Thick lipid films exerted high surface pressure at the air-aqueous interface, 50 ± 2 mN/m, with little inter- and intra-subject variability. The rheological storage modulus (E∞; 25.3 ± 2 mN/m) and relaxation time (τ; 87 ± 25 s) were similar among subjects. Neither lysozyme nor MPS changed the surface tension of the lipid multilayers. Lysozyme adsorbed irreversibly onto multilayers without changing E∞, but increased τ 2.5 times. Exposure of mixed multilayers to OFX reduced E∞ to less than a half of its original value (13 ± 4.5 mN/m; p rheology of the ex vivo lipids. OFX and OFR changed rheological properties of the mixed films to different extents. PMID:19901859

  15. Adsorption of proteins from artificial tear solutions to contact lens materials

    International Nuclear Information System (INIS)

    Bohnert, J.L.; Horbett, T.A.; Ratner, B.D.; Royce, F.H.

    1988-01-01

    A series of polymers and copolymers of 2-hydroxyethyl methacrylate (HEMA) and methyl methacrylate (MMA) were synthesized in order to find surfaces that would adsorb minimal amounts of protein. The adsorption of albumin, lysozyme and immunoglobulin G from a three-way mixture of these proteins in isotonic buffered saline to the polymers was measured using 125 I-labeled proteins. Apparently high protein uptake on copolymers rich in HEMA was found to be due to sorption of unbound 125 I by the polymers. 125 I sorption by the polymers was minimized by dialysis of the protein solution to remove unbound 125 I iodide and inclusion of 0.01 M sodium iodide to block uptake of residual 125 I iodide. Using these improved protocols, minimal total protein uptake was observed on copolymers containing 50% or more HEMA. The majority of adsorbed protein on all p(MMA-HEMA) polymers was albumin. Total protein uptake was greatest on pMMA. Commercial contact lenses composed of copolymers of HEMA and N-vinyl pyrrolidone (NVP) or acrylamide (AAm) adsorbed small amounts of all proteins whereas copolymers of methacrylic acid (MAAc) and HEMA adsorbed much larger quantities of lysozyme. These results indicate that protein uptake by contact lens materials varies greatly with polymer composition. Artifactually high adsorption can occur if precautions are not taken to prevent uptake of unbound 125 I

  16. Correlations of In Vitro Assays for Assessing Cytotoxicity and Biocompatibility of Contact Lens Multipurpose Solutions.

    Science.gov (United States)

    Huang, Ling C; Salvador-Silva, Mercedes; Leang, Ronika S

    2016-10-24

    To demonstrate correlations among in vitro assays used for assessing cytotoxicity of contact lens multipurpose solution (MPS) and propose the use of multiple assays as a part of preclinical evaluation for MPS biocompatibility assessment. The effect of four different MPS on cell cytotoxicity, metabolic activity, and membrane integrity was performed by evaluating toxicity, expression of tight junction protein zonula occludens-1, and transepithelial electrical resistance in human corneal epithelial cells and Chinese hamster fibroblast cells. Cytotoxicity of four MPS was assayed with five different experimental systems at various concentrations. In vitro MPS-induced cytotoxicity was dependent on assay choice, concentration of MPS used, and duration of treatment. Overall, MPS-1 and MPS-2 were comparable to MPS-4 and better than MPS-3 in maintaining corneal barrier integrity and cell viability. In vitro cytotoxicity testing with MPS exposure to monolayer of cells in culture could be used as a tool to understand the potential cytotoxicity profiles of MPS and possibly a predictor of clinical outcome. Furthermore, MPS effects on in vitro cytotoxicity are best demonstrated by performing multiple assays to evaluate cell viability, metabolic activity, and membrane integrity during development.

  17. Paraxial light distribution in the focal region of a lens: a comparison of several analytical solutions and a numerical result.

    Science.gov (United States)

    Wu, Yang; Kelly, Damien P

    2014-12-12

    The distribution of the complex field in the focal region of a lens is a classical optical diffraction problem. Today, it remains of significant theoretical importance for understanding the properties of imaging systems. In the paraxial regime, it is possible to find analytical solutions in the neighborhood of the focus, when a plane wave is incident on a focusing lens whose finite extent is limited by a circular aperture. For example, in Born and Wolf's treatment of this problem, two different, but mathematically equivalent analytical solutions, are presented that describe the 3D field distribution using infinite sums of [Formula: see text] and [Formula: see text] type Lommel functions. An alternative solution expresses the distribution in terms of Zernike polynomials, and was presented by Nijboer in 1947. More recently, Cao derived an alternative analytical solution by expanding the Fresnel kernel using a Taylor series expansion. In practical calculations, however, only a finite number of terms from these infinite series expansions is actually used to calculate the distribution in the focal region. In this manuscript, we compare and contrast each of these different solutions to a numerically calculated result, paying particular attention to how quickly each solution converges for a range of different spatial locations behind the focusing lens. We also examine the time taken to calculate each of the analytical solutions. The numerical solution is calculated in a polar coordinate system and is semi-analytic. The integration over the angle is solved analytically, while the radial coordinate is sampled with a sampling interval of [Formula: see text] and then numerically integrated. This produces an infinite set of replicas in the diffraction plane, that are located in circular rings centered at the optical axis and each with radii given by [Formula: see text], where [Formula: see text] is the replica order. These circular replicas are shown to be fundamentally

  18. Heterologous expression and solution structure of defensin from lentil Lens culinaris

    International Nuclear Information System (INIS)

    Shenkarev, Zakhar O.; Gizatullina, Albina K.; Finkina, Ekaterina I.; Alekseeva, Ekaterina A.; Balandin, Sergey V.; Mineev, Konstantin S.; Arseniev, Alexander S.; Ovchinnikova, Tatiana V.

    2014-01-01

    Highlights: • Lentil defensin Lc-def and its 15 N-labeled analog were overexpressed in E. coli. • Lc-def is active against fungi, but does not inhibit growth of G+ and G− bacteria. • Lc-def spatial structure involves triple-stranded β-sheet and α-helix (CSαβ motif). • Lc-def is able to bind to anionic lipid vesicles under low-salt conditions. • NMR data revealed significant μs–ms mobility in the loops 1 and 3 of Lc-def. - Abstract: A new defensin Lc-def, isolated from germinated seeds of the lentil Lens culinaris, has molecular mass 5440.4 Da and consists of 47 amino acid residues. Lc-def and its 15 N-labeled analog were overexpressed in Escherichia coli. Antimicrobial activity of the recombinant protein was examined, and its spatial structure, dynamics, and interaction with lipid vesicles were studied by NMR spectroscopy. It was shown that Lc-def is active against fungi, but does not inhibit the growth of Gram-positive and Gram-negative bacteria. The peptide is monomeric in aqueous solution and contains one α-helix and triple-stranded β-sheet, which form cysteine-stabilized αβ motif (CSαβ) previously found in other plant defensins. The sterically neighboring loop1 and loop3 protrude from the defensin core and demonstrate significant mobility on the μs–ms timescale. Lc-def does not bind to the zwitterionic lipid (POPC) vesicles but interacts with the partially anionic (POPC/DOPG, 7:3) membranes under low-salt conditions. The Lc-def antifungal activity might be mediated through electrostatic interaction with anionic lipid components of fungal membranes

  19. Spacecraft sterilization.

    Science.gov (United States)

    Kalfayan, S. H.

    1972-01-01

    Spacecraft sterilization is a vital factor in projects for the successful biological exploration of other planets. The microorganisms of major concern are the fungi and bacteria. Sterilization procedures are oriented toward the destruction of bacterial spores. Gaseous sterilants are examined, giving attention to formaldehyde, beta-propiolactone, ethylene oxide, and the chemistry of the bactericidal action of sterilants. Radiation has been seriously considered as another method for spacecraft sterilization. Dry heat sterilization is discussed together with the effects of ethylene oxide decontamination and dry heat sterilization on materials.

  20. Indigenous technology development and standardization of the process for obtaining ready to use sterile sodium pertechnetate-Tc-99m solution from Geltech generator

    International Nuclear Information System (INIS)

    Sarkar, Sishir Kumar; Kothalkar, Chetan; Naskar, Prabhakar; Joshi, Sangeeta; Saraswathy, Padmanabhan; Dey, Arun Chandra; Vispute, Gunvant Leeladhar; Murhekar, Vishwas Vinayak; Pilkhwal, Neelam

    2013-01-01

    The indigenous design and technology development for processing large scale zirconium molybdate-Mo-99 (ZrMo-99) Geltech generator was successfully commissioned in Board of Radiation and Isotope Technology (BRIT), India, in 2006. The generator production facility comprises of four shielded plant facilities equipped with tongs and special process gadgets amenable for remote operations for radiochemical processing of ZrMo-99 gel. Over 2800 Geltech generators have been processed and supplied to user hospitals during the period 2006-2013. Geltech generator supplied by BRIT was initially not sterile. Simple elution of 99m Tc is performed by a sterile evacuated vial with sterile and pyrogen free 0.9% NaCl solution to obtain sodium ( 99m Tc) pertechnetate solution. A special type online 0.22 μm membrane filter has been identified and adapted in Geltech generator. The online filtration of 99m Tc from Geltech generator; thus, provided sterile 99m Tc sodium pertechnetate solution. Generators assembled with modified filter assembly were supplied to local hospital in Mumbai (Radiation Medicine Centre (RMC) and S.G.S. Medical College and KEM Hospital) and excellent performances were reported by users. (author)

  1. Indigenous technology development and standardization of the process for obtaining ready to use sterile sodium pertechnetate-Tc-99m solution from Geltech generator.

    Science.gov (United States)

    Sarkar, Sishir Kumar; Kothalkar, Chetan; Naskar, Prabhakar; Joshi, Sangeeta; Saraswathy, Padmanabhan; Dey, Arun Chandra; Vispute, Gunvant Leeladhar; Murhekar, Vishwas Vinayak; Pilkhwal, Neelam

    2013-04-01

    The indigenous design and technology development for processing large scale zirconium molybdate-Mo-99 (ZrMo-99) Geltech generator was successfully commissioned in Board of Radiation and Isotope Technology (BRIT), India, in 2006. The generator production facility comprises of four shielded plant facilities equipped with tongs and special process gadgets amenable for remote operations for radiochemical processing of ZrMo-99 gel. Over 2800 Geltech generators have been processed and supplied to user hospitals during the period 2006-2013. Geltech generator supplied by BRIT was initially not sterile. Simple elution of Tc-99m is performed by a sterile evacuated vial with sterile and pyrogen free 0.9% NaCl solution to obtain sodium (Tc-99m) pertechnetate solution. A special type online 0.22 μm membrane filter has been identified and adapted in Geltech generator. The online filtration of Tc-99m from Geltech generator; thus, provided sterile Tc-99m sodium pertechnetate solution. Generators assembled with modified filter assembly were supplied to local hospital in Mumbai Radiation Medicine Centre (RMC) and S.G.S. Medical College and KEM Hospital) and excellent performances were reported by users.

  2. Targeting cyst wall is an effective strategy in improving the efficacy of marketed contact lens disinfecting solutions against Acanthamoeba castellanii cysts.

    Science.gov (United States)

    Abjani, Farhat; Khan, Naveed Ahmed; Yousuf, Farzana Abubakar; Siddiqui, Ruqaiyyah

    2016-06-01

    Acanthamoeba cysts are highly resistant to contact lens disinfecting solutions. Acanthamoeba cyst wall is partially made of 1,4 β-glucan (i.e., cellulose) and other complex polysaccharides making it a hardy shell that protects the resident amoeba. Here, we hypothesize that targeting the cyst wall structure in addition to antiamoebic compound would improve the efficacy of marketed contact lens disinfecting solutions. Using chlorhexidine as an antiamoebic compound and cellulase enzyme to disrupt cyst wall structure, the findings revealed that combination of both agents abolished viability of Acanthamoeba castellanii cysts and trophozoites. When tested alone, none of the agents nor contact lens disinfecting solutions completely destroyed A. castellanii cysts and trophozoites. The absence of cyst wall-degrading enzymes in marketed contact lens disinfecting solutions render them ineffective against Acanthamoeba cysts. It is concluded that the addition of cyst wall degrading molecules in contact lens disinfecting solutions will enhance their efficacy in decreasing the incidence of Acanthamoeba effectively. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  3. A similarity solution for oil lens redistribution including capillary forces and oil entrapment.

    NARCIS (Netherlands)

    Dijke, van J.; Zee, van der S.E.A.T.M.

    1997-01-01

    Redistribution of a LNAPL lens (oil) at the phreatic surface is described using a multi-phase flow model, with emphasis on the effect of oil entrapment by water. The flow process is analyzed under the assumption that the vertical capillary and gravitational forces balance. Vertical integration leads

  4. Reversible Sterilization

    Science.gov (United States)

    Largey, Gale

    1977-01-01

    Notes that difficult questions arise concerning the use of sterilization for alleged eugenic and euthenic purposes. Thus, how reversible sterilization will be used with relation to the poor, mentally ill, mentally retarded, criminals, and minors, is questioned. (Author/AM)

  5. Sterilization System

    Science.gov (United States)

    1990-01-01

    Cox Sterile Products, Inc.'s Rapid Heat Transfer Sterilizer employs a heat exchange process that induces rapid air movement; the air becomes the heat transfer medium, maintaining a uniform temperature of 375 degrees Fahrenheit. It features pushbutton controls for three timing cycles for different instrument loads, a six-minute cycle for standard unpackaged instruments, eight minutes for certain specialized dental/medical instruments and 12 minutes for packaged instruments which can then be stored in a drawer in sterile condition. System will stay at 375 degrees all day. Continuous operation is not expensive because of the sterilizer's very low power requirements.

  6. High-spatial-resolution isotropic three-dimensional fast-recovery fast spin-echo magnetic resonance dacryocystography combined with topical administration of sterile saline solution

    Energy Technology Data Exchange (ETDEWEB)

    Jing, Zhang, E-mail: hbtjzj@yahoo.com.cn [Department of Radiology, Tongji Hospital, Huazhong University of Science and Technology, Wuhan 430030 (China); Lang, Chen, E-mail: langc731@yahoo.com.cn [Department of Radiology, Tongji Hospital, Huazhong University of Science and Technology, Wuhan 430030 (China); Qiu-Xia, Wang, E-mail: guaiqiuqiu1981@163.com [Department of Radiology, Tongji Hospital, Huazhong University of Science and Technology, Wuhan 430030 (China); Rong, Liu, E-mail: rongr007@yahoo.com.cn [Department of Ophthalmology, Tongji Hospital, Huazhong University of Science and Technology, Wuhan 430030 (China); Xin, Luo, E-mail: hoyoho2000@sina.com [Department of Radiology, Tongji Hospital, Huazhong University of Science and Technology, Wuhan 430030 (China); Wen-Zhen, Zhu, E-mail: zhuwenzhen@hotmail.com [Department of Radiology, Tongji Hospital, Huazhong University of Science and Technology, Wuhan 430030 (China); Li-Ming, Xia, E-mail: limingxia@tjh.tjmu.edu.cn [Department of Radiology, Tongji Hospital, Huazhong University of Science and Technology, Wuhan 430030 (China); Jian-Pin, Qi, E-mail: qijp2k01@yahoo.com [Department of Radiology, Tongji Hospital, Huazhong University of Science and Technology, Wuhan 430030 (China); He, Wang, E-mail: he.wang@ge.com [GE Healthcare, 1 Build, 2F C109, 1 Hua TuoRoad, Zhang Jiang Hi-Tech Park, Shanghai 201203 (China)

    2013-09-15

    Objective: This study aims to investigate the clinical performance of three-dimensional (3D) fast-recovery fast spin-echo (FRFSE) magnetic resonance dacryocystography (MRD) with topical administration of sterile saline solution for the assessment of the lacrimal drainage system (LDS). Methods: A total of 13 healthy volunteers underwent both 3D-FRFSE MRD and two-dimensional (2D)-impulse recovery (IR)-single-shot fast spin-echo (SSFSE) MRD after topical administration of sterile saline solution, and 31 patients affected by primary LDS outflow impairment or postsurgical recurrent epiphora underwent 3D-FRFSE MRD and conventional T1- and T2-weighted sequences. All patients underwent lacrimal endoscopy or surgery, which served as a standard of reference for confirming the MRD findings. Results: 3D-FRFSE MRD detected more visualized superior and inferior canaliculi and nasolacrimal duct than 2D-IR-SSFSE MRD. Compared with 2D-IR-SSFSE MRD, 3D-FRFSE MRD showed more visualized segments per LDS, although the difference was not statistically significant. Significant improvements in the inferior canaliculus and nasolacrimal duct visibility grades were achieved using 3D-FRFSE MRD. 3D-FRFSE MRD had 100% sensitivity and 63.6% specificity for detecting LDS obstruction. In 51 out of the 62 LDSs that were assessed, a 90% agreement was noted between the findings of 3D-FRFSE MRD and lacrimal endoscopy in detecting the obstruction level. Conclusion: 3D-FRFSE MRD combined with topical administration of sterile saline solution is a simple and noninvasive method of obtaining detailed morphological and functional information on the LDS. Overall, 3D-FRFSE MRD could be used as a reliable diagnostic method in many patients with epiphora prior to surgery.

  7. Differences in solution dynamics between lens β-crystallin homodimers and heterodimers probed by hydrogen-deuterium exchange and deamidation.

    Science.gov (United States)

    Lampi, Kirsten J; Murray, Matthew R; Peterson, Matthew P; Eng, Bryce S; Yue, Eileen; Clark, Alice R; Barbar, Elisar; David, Larry L

    2016-01-01

    Lens transparency is due to the ordered arrangement of the major structural proteins, called crystallins. βB2 crystallin in the lens of the eye readily forms dimers with other β-crystallin subunits, but the resulting heterodimer structures are not known and were investigated in this study. Structures of βA3 and βB2 crystallin homodimers and the βA3/βB2 crystallin heterodimers were probed by measuring changes in solvent accessibility using hydrogen-deuterium exchange with mass spectrometry. We further mimicked deamidation in βB2 and probed the effect on the βA3/βB2 heterodimer. Results were confirmed with chemical crosslinking and NMR. Both βA3 and βB2 had significantly decreased deuterium levels in the heterodimer compared to their respective homodimers, suggesting that they had less solvent accessibility and were more compact in the heterodimer. The compact structure of βB2 was supported by the identification of chemical crosslinks between lysines in βB2 within the heterodimer that were inconsistent with βB2's extended homodimeric structure. The compact structure of βA3 was supported by an overall decrease in mobility of βA3 in the heterodimer detected by NMR. In βB2, peptides 70-84 and 121-134 were exposed in the homodimer, but buried in the heterodimer with ≥50% decreases in deuterium levels. Homologous peptides in βA3, 97-109 and 134-149, had 25-50% decreases in deuterium levels in the heterodimer. These peptides are probable sites of interaction between βB2 and βA3 and are located at the predicted interface between subunits with bent linkers. Deamidation at Q184 in βB2 at this predicted interface led to a less compact βB2 in the heterodimer. The more compact structure of the βA3/βB2 heterodimer was also more heat stable than either of the homodimers. The major structural proteins in the lens, the β-crystallins, are not static, but dynamic in solution, with differences in accessibility between the homo-and hetero-dimers. This

  8. Does the presence of QAC genes in staphylococci affect the efficacy of disinfecting solutions used by orthokeratology lens wearers?

    Science.gov (United States)

    Shi, Guang-sen; Boost, Maureen V; Cho, Pauline

    2016-05-01

    There has been increasing evidence of the emergence of antiseptic resistance mediated by quaternary ammonium compound (QAC) resistance genes, which may reduce the efficacy of disinfection. Although the presence of QAC-positive staphylococci has been shown to be elevated in contact lens wearers, the efficacy of multipurpose solutions (MPS) against such isolates has not been determined. This study investigated the efficacy of four MPS for rigid gas permeable (RGP) lenses against staphylococci-harbouring QAC genes. Ability to reduce viability by three or more log reductions of four MPS for RGP lenses was tested against 60 disinfectant-resistant gene-positive staphylococci, comprising 38 coagulase-negative staphylococci (CNS) (17 ITALIC! qacA/B, 7 ITALIC! smr, 5 ITALIC! qacH, 9 habouring two or more genes) and 22 ITALIC! Staphylococcus aureus (16 ITALIC! qacA/B, 4 ITALIC! smr, 2 ITALIC! qacA/B+ ITALIC! smr)). 60 gene-negative isolates of staphylococci (30 CNS and 30 ITALIC! S aureus) were used as controls. Minimum inhibitory concentrations (MICs) and minimum bactericidal concentrations (MBCs) of these four MPS were determined. Although there was some variation between solutions, all failed to achieve a 3-log reduction in some ITALIC! S aureus and CNS isolates. Strains harbouring disinfectant-resistant genes were significantly less likely to be reduced by 3 logs by three of the solutions. Overall, the MIC and MBC of the four MPS against gene-positive clinical isolates were significantly higher than those of gene-negative isolates. The efficacy of MPS solutions for RGP lenses against staphylococci varied. The presence of disinfectant-resistance genes significantly adversely affected disinfecting capacity of RGP solutions. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  9. Recombinant production and solution structure of lipid transfer protein from lentil Lens culinaris

    International Nuclear Information System (INIS)

    Gizatullina, Albina K.; Finkina, Ekaterina I.; Mineev, Konstantin S.; Melnikova, Daria N.; Bogdanov, Ivan V.; Telezhinskaya, Irina N.; Balandin, Sergey V.; Shenkarev, Zakhar O.; Arseniev, Alexander S.; Ovchinnikova, Tatiana V.

    2013-01-01

    Highlights: •Lipid transfer protein from lentil seeds (Lc-LTP2) was overexpressed in E. coli. •Antimicrobial activity and spatial structure of the recombinant Lc-LTP2 were examined. •Internal tunnel-like lipid-binding cavity occupies ∼7% of the total Lc-LTP2 volume. •Binding of DMPG lipid induces moderate rearrangements in the Lc-LTP2 structure. •Lc-LTP2/DMPG complex has limited lifetime and dissociates within tens of hours. -- Abstract: Lipid transfer protein, designated as Lc-LTP2, was isolated from seeds of the lentil Lens culinaris. The protein has molecular mass 9282.7 Da, consists of 93 amino acid residues including 8 cysteines forming 4 disulfide bonds. Lc-LTP2 and its stable isotope labeled analogues were overexpressed in Escherichia coli and purified. Antimicrobial activity of the recombinant protein was examined, and its spatial structure was studied by NMR spectroscopy. The polypeptide chain of Lc-LTP2 forms four α-helices (Cys4-Leu18, Pro26-Ala37, Thr42-Ala56, Thr64-Lys73) and a long C-terminal tail without regular secondary structure. Side chains of the hydrophobic residues form a relatively large internal tunnel-like lipid-binding cavity (van der Waals volume comes up to ∼600 Å 3 ). The side-chains of Arg45, Pro79, and Tyr80 are located near an assumed mouth of the cavity. Titration with dimyristoyl phosphatidylglycerol (DMPG) revealed formation of the Lc-LTP2/lipid non-covalent complex accompanied by rearrangements in the protein spatial structure and expansion of the internal cavity. The resultant Lc-LTP2/DMPG complex demonstrates limited lifetime and dissociates within tens of hours

  10. Sterile neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Kopp, J. [PRISMA Cluster of Excellence & Mainz Institute for Theoretical Physics, Johannes Gutenberg University, 55099 Mainz (Germany); Machado, P. A. N., E-mail: pedro.machado@uam.es [Departamento de Física Teórica, Universidad Autónoma de Madrid, Cantoblanco E-28049 Madrid (Spain); Instituto de Física Teórica UAM/CSIC, Calle Nicolás Cabrera 13-15, Cantoblanco E-28049 Madrid (Spain); Maltoni, M. [Instituto de Física Teórica UAM/CSIC, Calle Nicolás Cabrera 13-15, Cantoblanco E-28049 Madrid (Spain); Schwetz, T. [Institute for Nuclear Physics, Karlsruhe Institute of Technology (KIT), Postfach 3640, 76021 Karlsruhe (Germany)

    2016-06-21

    We characterize statistically the indications of a presence of one or more light sterile neutrinos from MiniBooNE and LSND data, together with the reactor and gallium anomalies, in the global context. The compatibility of the aforementioned signals with null results from solar, atmospheric, reactor, and accelerator experiments is evaluated. We conclude that a severe tension is present in the global fit, and therefore the addition of eV-scale sterile neutrinos does not satisfactorily explain the anomalies.

  11. Cryoradiation sterilization - contemporary state and outlook

    International Nuclear Information System (INIS)

    Talrose, V.L.

    1995-01-01

    The new approach of radiation sterilization -cryoradiosterilization with programmed freezing - was developed for pharmaceutical solutions. Both scientific and technical problems are solved, the results are discussed. Programmed freezing of vials with the drug's solutions provides the high stability of soluted components with biological activity at sterilizing irradiation without significant change of sterilization doses. Physical, chemical, biological and pharmacological properties of a lot of drug solutions for injection satisfy official requirements after cryoradiation sterilization treatment. This method seems to be especially important for the protein systems which could be infected by dangerous viruses (VIH, hepatitis B): blood plasma, diagnostic sera, protein preparations manufactured from donor's blood, etc. (Author)

  12. First autoclave-sterilized platelet-additive solution containing glucose with a physiological pH for the preparation of plasma-poor platelet concentrates.

    Science.gov (United States)

    Shimizu, T; Shibata, K; Kora, S

    1992-01-01

    The glucose-free platelet-additive solution (termed AR solution), developed by Adams and Rock [Transfusion 1988;28:217-220], was modified by adding glucose as an energy substrate for platelets and maltose to prevent platelet lysis and by replacing sodium gluconate with sodium phosphate for better pH maintenance. The new platelet-additive solution (termed Seto solution) contained 90 mM NaCl, 5 mM KCl, 3 mM MgCl2, 17 mM tri-sodium citrate, 4.9 mM NaH2PO4, 20.1 mM Na2HPO4, 23 mM sodium acetate, 28.8 mM maltose, and 23.5 mM glucose with a pH of 7.4. The solution was sterilized by autoclaving in plastic bags in nitrogen to prevent glucose caramelization at high pH. Plasma-poor platelet concentrates prepared by adding Seto solution to the pelleted platelet buttons were stored in a LE-2 polyolefin bag at 22 degrees C with constant agitation for 5 days. The platelets suspended in Seto solution maintained oxygen consumption at a rate of 1.1 nmol/min/10(9) platelets after 5-day storage, with glucose consumption and lactate production rates of 0.5 +/- 0.2 and 1.2 +/- 0.2 nmol/min/10(9) platelets, respectively. This resulted in a final mean pH of 7.0. Those suspended in AR solution ceased glycolysis within 3 days because residual plasma glucose had been consumed. This was associated with decreases in percent hypotonic shock response and aggregation induced by adenosine diphosphate and collagen. Lactate dehydrogenase discharge in AR solution was 5 and 8 times higher at day 3 and day 5, respectively, than that of Seto solution. Morphologically, there were no ballooned platelets after storage in Seto solution.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Linear and Non-Linear Thermal Lens Signal of the Fifth C-H Vibrational Overtone of Naphthalene in Liquid Solutions of Hexane

    Science.gov (United States)

    Manzanares, Carlos; Diaz, Marlon; Barton, Ann; Nyaupane, Parashu R.

    2017-06-01

    The thermal lens technique is applied to vibrational overtone spectroscopy of solutions of naphthalene in n-hexane. The pump and probe thermal lens technique is found to be very sensitive for detecting samples of low composition (ppm) in transparent solvents. In this experiment two different probe lasers: one at 488 nm and another 568 nm were used. The C-H fifth vibrational overtone spectrum of benzene is detected at room temperature for different concentrations. A plot of normalized integrated intensity as a function of concentration of naphthalene in solution reveals a non-linear behavior at low concentrations when using the 488 nm probe and a linear behavior over the entire range of concentrations when using the 568 nm probe. The non-linearity cannot be explained assuming solvent enhancement at low concentrations. A two color absorption model that includes the simultaneous absorption of the pump and probe lasers could explain the enhanced magnitude and the non-linear behavior of the thermal lens signal. Other possible mechanisms will also be discussed.

  14. Linear and Nonlinear Thermal Lens Signal of the (Δν = 6) C-H Vibrational Overtone of Naphthalene in Liquid Solutions of n-Hexane.

    Science.gov (United States)

    Nyaupane, Parashu R; Diaz, Marlon; Barton, Ann; Manzanares, Carlos E

    2018-01-01

    The thermal lens technique is applied to vibrational overtone spectroscopy of solutions of naphthalene (C 10 H 8 ) in liquid hexane. The C-H fifth vibrational (Δν = 6) overtone spectrum of C 10 H 8 is detected at room temperature for mole fractions from 0.08 to 19 × 10 -6 using n-C 6 H 14 as solvent. By detecting the absorption band in a 19 ppm (parts per million) solution, the peak absorption of the signal is approximately (2.2 ± 0.3) × 10 -7  cm -1 . A plot of normalized integrated intensity as a function of the mole fraction of naphthalene in solution reveals a dependence of the magnitude of the signal with the probe laser wavelength. If the wavelength of the probe laser is 568 nm, the thermal lens signal (TLS) is linear as a function of the mole fraction of the solution. When the wavelength of the probe laser is 488 nm, the TLS is nonlinear as a function of the concentration. Three different models of nonlinear absorption are discussed. A two-color absorption model that includes the simultaneous absorption of the pump and probe lasers could explain the enhanced magnitude and the nonlinear behavior of the TLS for solutions of mole fraction < 0.1%.

  15. Viscous froth lens

    Science.gov (United States)

    Green, T. E.; Bramley, A.; Lue, L.; Grassia, P.

    2006-11-01

    Microscale models of foam structure traditionally incorporate a balance between bubble pressures and surface tension forces associated with curvature of bubble films. In particular, models for flowing foam microrheology have assumed this balance is maintained under the action of some externally imposed motion. Recently, however, a dynamic model for foam structure has been proposed, the viscous froth model, which balances the net effect of bubble pressures and surface tension to viscous dissipation forces: this permits the description of fast-flowing foam. This contribution examines the behavior of the viscous froth model when applied to a paradigm problem with a particularly simple geometry: namely, a two-dimensional bubble “lens.” The lens consists of a channel partly filled by a bubble (known as the “lens bubble”) which contacts one channel wall. An additional film (known as the “spanning film”) connects to this bubble spanning the distance from the opposite channel wall. This simple structure can be set in motion and deformed out of equilibrium by applying a pressure across the spanning film: a rich dynamical behavior results. Solutions for the lens structure steadily propagating along the channel can be computed by the viscous froth model. Perturbation solutions are obtained in the limit of a lens structure with weak applied pressures, while numerical solutions are available for higher pressures. These steadily propagating solutions suggest that small lenses move faster than large ones, while both small and large lens bubbles are quite resistant to deformation, at least for weak applied back pressures. As the applied back pressure grows, the structure with the small lens bubble remains relatively stiff, while that with the large lens bubble becomes much more compliant. However, with even further increases in the applied back pressure, a critical pressure appears to exist for which the steady-state structure loses stability and unsteady

  16. TWO STARS TWO WAYS: CONFIRMING A MICROLENSING BINARY LENS SOLUTION WITH A SPECTROSCOPIC MEASUREMENT OF THE ORBIT

    Energy Technology Data Exchange (ETDEWEB)

    Yee, Jennifer C.; Johnson, John Asher; Eastman, Jason; Vanderburg, Andrew [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Skowron, Jan [Warsaw University Observatory, Al. Ujazdowskie 4, 00-478 Warszawa (Poland); Gould, Andrew [Department of Astronomy, Ohio State University, 140 West 18th Avenue, Columbus, OH 43210 (United States); Pineda, J. Sebastian [Department of Astronomy, California Institute of Technology, 1200 East California Boulevard, MC 249-17, Pasadena, CA 91125 (United States); Howard, Andrew, E-mail: jyee@cfa.harvard.edu, E-mail: jjohnson@cfa.harvard.edu, E-mail: jason.eastman@cfa.harvard.edu, E-mail: avanderburg@cfa.harvard.edu [Institute for Astronomy, University of Hawaii, 2680 Woodlawn Drive, Honolulu, HI 96822-1839 (United States)

    2016-04-20

    Light curves of microlensing events involving stellar binaries and planetary systems can provide information about the orbital elements of the system due to orbital modulations of the caustic structure. Accurately measuring the orbit in either the stellar or planetary case requires detailed modeling of subtle deviations in the light curve. At the same time, the natural, Cartesian parameterization of a microlensing binary is partially degenerate with the microlens parallax. Hence, it is desirable to perform independent tests of the predictions of microlens orbit models using radial velocity (RV) time series of the lens binary system. To this end, we present 3.5 years of RV monitoring of the binary lens system OGLE-2009-BLG-020 L, for which Skowron et al. constrained all internal parameters of the 200–700 day orbit. Our RV measurements reveal an orbit that is consistent with the predictions of the microlens light curve analysis, thereby providing the first confirmation of orbital elements inferred from microlensing events.

  17. Asymptotic solutions for the case of SIE lens models and application to the quadruply imaged quasar Q2237+0305

    Science.gov (United States)

    Wertz, O.; Surdej, J.

    2014-07-01

    Considering a small misalignment between a point-like source, a singular isothermal ellipsoid deflector and an observer, we derive to first order simple relations between the model parameters and the lensed image positions, and an expression for the time delay between pairs of opposed images which is analogue to the one previously derived for the case of ɛ - γ models. Combined with the first-order astrometric relations, we retrieve a simple expression for the time delays, in agreement with Witt, Mao & Keeton, which solely depends on the lensed image positions. The real advantage of using the first-order equations when dealing with symmetric gravitational lens systems is to directly test the validity of the adopted lens model without having to perform any accurate numerical fit. In this paper, we present in detail the calculations which lead to those relations between the singular isothermal ellipsoid lens model parameters and the lensed image positions. In addition, we model the well-known Einstein cross Q2237+0305 with three families of models: ɛ - γ, singular isothermal ellipsoid and non-singular isothermal ellipsoid plus shear, using a genetic algorithm from the Qubist Optimization Toolbox. We conclude that although the non-singular isothermal ellipsoid plus shear model shows the best agreement between the calculated and the observed image positions ( = 0.0026 arcsec), the more simple singular isothermal ellipsoid also leads to quite satisfactory and acceptable results ( = 0.0059 arcsec).

  18. Stability of 10 mg/mL cefuroxime solution for intracameral injection in commonly used polypropylene syringes and new ready-to-use cyclic olefin copolymer sterile vials using the LC-UV stability-indicating method.

    Science.gov (United States)

    Feutry, Frédéric; Simon, Nicolas; Genay, Stéphanie; Lannoy, Damien; Barthélémy, Christine; Décaudin, Bertrand; Labalette, Pierre; Odou, Pascal

    2016-01-01

    Injecting intracameral cefuroxime has been found beneficial in reducing the risk of postoperative endophthalmitis but its use has been limited through a lack of approved marketing and of ready-to-use single-units as well as the problem of aseptic compounding. Our aim was to assess a new automated primary packaging system which should ensure a higher level of sterility, thanks to its closed, sterile, ready-to-use polymer vial called "Crystal® vial". The chemical stability of a 10 mg/mL cefuroxime solution was compared in 1 mL Crystal® vials and 1 mL Luer-lock polypropylene syringes (actual reference) to eliminate any potential and specific interactions with its cyclic olefin copolymer (COC) body and elastomer stopper. Cefuroxime solution was introduced into vials and syringes and stored at -20 °C, +5 °C and +25°C/60% Relative Humidity. Cefuroxime concentration and the relative amount of the main degradation product (descarbamoyl-cefuroxime) were both determined by an HPLC/UV method indicating stability. Solutions were considered steady if the concentration remained at over 90% of the initial value. In the adapted storage conditions, the evolution of osmolality, pH and sterility was assessed. Stability profiles were identical between vials and syringes in all storage and temperature conditions. The solution was stable (cefuroxime concentration, pH and osmolality) and still sterile for 365 days at -20°C. The concentration fell below 90% after 21 days at +5 °C and after 16 h at +25°C/60%s relative humidity. The COC and thermoplastic elastomer of the vials had no impact on the degradation process confirming its possible use for a ready-to-use cefuroxime solution single-unit dose.

  19. Clinical survey of lens care in contact lens patients.

    Science.gov (United States)

    Ky, W; Scherick, K; Stenson, S

    1998-10-01

    Overall, contact lenses provide a safe and effective modality for vision correction. However, problems do occasionally arise. Up to 80% of contact lens complications can be traced to poor patient compliance with recommended lens care guidelines. We conducted a survey to evaluate the level of patient compliance in specific areas of lens care and maintenance and to assess patient knowledge of basic contact lens information. Patients were asked to complete an anonymous 15 question survey that focused on lens care--specifically the use of contact lens cleaners, methods of disinfection, enzyme treatments, use of rewetting drops, and the frequency of follow-up exams. In addition, the survey included six true/false questions relating to contact lens care and safety. There were a total of 103 participants in the study. Approximately 24% of patients stated they never cleaned their lenses prior to disinfection, and 5% used saline solutions as their primary mode of disinfection. A sizable portion of those surveyed (43% of soft lens wearers and 71% of rigid gas permeable lens wearers) either never used enzyme cleaners or used them less than once a month. Seventy percent of patients either never used rewetting drops or used them less than once a day. Twenty-nine percent of patients consulted their eye care professionals every 2 years and 6% less often than every two years. Six questions assessed patient knowledge of contact lens care safety. Of a possible six out of six correct answers, the mean number of correct responses was 3.74. A sizable proportion of contact lens wearers do not adequately adhere to recommended contact lens care, and many have an inadequate understanding of contact lens care guidelines. Therefore, it is important that practitioners place more emphasis on patient education at the time of initial contact lens fitting and reinforce such instruction during follow-up visits.

  20. Interval Female Sterilization.

    Science.gov (United States)

    Stuart, Gretchen S; Ramesh, Shanthi S

    2018-01-01

    Female sterilization is relied on by nearly one in three women aged 35-44 years in the United States. Sterilization procedures are among the most common procedures that obstetrician-gynecologists perform. The most frequent sterilization procedures include postpartum tubal ligation, laparoscopic tubal disruption or salpingectomy, and hysteroscopic tubal occlusion. The informed consent process for sterilization is crucial and requires shared decision-making between the patient and the health care provider. Counseling should include the specific risks and benefits of the specific surgical approaches. Additionally, women should be counseled on the alternatives to sterilization, including intrauterine contraceptives and subdermal contraceptive implants. Complications, including unplanned pregnancy after successful female sterilization, are rare. The objectives of this Clinical Expert Series are to describe the epidemiology of female sterilization, access to postpartum sterilization, advances in interval sterilization techniques, and clinical considerations in caring for women requesting sterilization.

  1. Objective lens

    Science.gov (United States)

    Olczak, Eugene G. (Inventor)

    2011-01-01

    An objective lens and a method for using same. The objective lens has a first end, a second end, and a plurality of optical elements. The optical elements are positioned between the first end and the second end and are at least substantially symmetric about a plane centered between the first end and the second end.

  2. Prolonging contact lens wear and making contact lens wear safer.

    Science.gov (United States)

    Foulks, Gary N

    2006-02-01

    To summarize the present status of safety and efficacy of contact lens wear. Literature review. Ovid Medline searches were performed on records from 1966 through 2005 using keywords: keratitis, contact lens complications, extended-wear contact lenses, and silicone-hydrogel contact lenses. Patients desire comfort, clarity of vision, and prolonged contact lens wear when contact lenses are used to correct refractive error. Practitioners desire patient satisfaction but also require maintenance of the integrity of the eye and no complications that jeopardize vision or health of the eye. Improvements in the oxygen permeability of the contact lens materials, design of the contact lens and its surface, and solutions for the maintenance of the lens have reduced but not eliminated the risks of infection, inflammation, and conjunctival papillary reaction associated with contact lens wear. The lessons of past and recent history suggest that patient education and practitioner participation in the management of contact lens wear continue to be critical factors for patient satisfaction and safety in the extended wear of contact lenses. The availability of highly oxygen permeable contact lenses has increased the tolerance and safety of extended contact lens wear, but patient instruction and education in proper use and care of lenses is required and caution is advised.

  3. ISO radiation sterilization standards

    International Nuclear Information System (INIS)

    Lambert, Byron J.; Hansen, Joyce M.

    1998-01-01

    This presentation provides an overview of the current status of the ISO radiation sterilization standards. The ISO standards are voluntary standards which detail both the validation and routine control of the sterilization process. ISO 11137 was approved in 1994 and published in 1995. When reviewing the standard you will note that less than 20% of the standard is devoted to requirements and the remainder is guidance on how to comply with the requirements. Future standards developments in radiation sterilization are being focused on providing additional guidance. The guidance that is currently provided in informative annexes of ISO 11137 includes: device/packaging materials, dose setting methods, and dosimeters and dose measurement, currently, there are four Technical Reports being developed to provide additional guidance: 1. AAMI Draft TIR, 'Radiation Sterilization Material Qualification' 2. ISO TR 13409-1996, 'Sterilization of health care products - Radiation sterilization - Substantiation of 25 kGy as a sterilization dose for small or infrequent production batches' 3. ISO Draft TR, 'Sterilization of health care products - Radiation sterilization Selection of a sterilization dose for a single production batch' 4. ISO Draft TR, 'Sterilization of health care products - Radiation sterilization-Product Families, Plans for Sampling and Frequency of Dose Audits'

  4. Clinical Presentation and Antibiotic Susceptibility of Contact Lens Associated Microbial Keratitis

    Directory of Open Access Journals (Sweden)

    Hesam Hedayati

    2015-01-01

    Full Text Available Introduction. In recent years, the number of contact lens wearers has dramatically increased in Iran, particularly in youngsters. The purpose of current study was to assess the clinical presentation and antibiotic susceptibility of contact lens related microbial keratitis in Ahvaz, southwest of Iran. Methodology. A cross-sectional investigation of 26 patients (33 eyes with contact lens induced corneal ulcers who were admitted to Imam Khomeini Hospital, Ahwaz City, from June 2012 to June 2013 was done. In order to study microbial culture and susceptibility of corneal ulcers, all of them were scraped. Results. Eight samples were reported as sterile. Pseudomonas aeruginosa (80% in positive cultures was the most widely recognized causative organism isolated. This is followed by Staphylococcus aureus 12% and Enterobacter 8%. The results showed that 84% of the microorganism cases were sensitive to ciprofloxacin, while imipenem, meropenem, and ceftazidime were the second most effective antibiotics (76%. Conclusion. Results of current study show the importance of referring all contact lens wearers with suspected corneal infection to ophthalmologists for more cure. The corneal scraping culture and contact lens solution should be performed to guide antibiotic therapy.

  5. Development of hydroponic system using agricultural waste. 2. Utilization of ozone for sterilization of nutrient solution; Suiko saibai ni okeru haikibutsu riyo gijutsu no kaihatsu. 2. Ozone ni yoru baiyoeki sakkin ni kansuru kento

    Energy Technology Data Exchange (ETDEWEB)

    Terazoe, H.; Yoshihara, T.; Nakaya, K. [Central Research Institute of Electric Power Industry, Tokyo (Japan)

    1995-08-01

    Discussions were given on a sterilizing effect of ozone on Fusarium bacteria in hydroponic culture, and its effect on components in the culture solution. In an experiment, dry air with O3 concentration of 3.5 ppm was sent into aqueous solution inoculated with Fusarium bacteria at a flow rate of 5 liters per minute. The Fusarium bacteria was sterilized nearly completely in about five minutes. No change was observed in pH, EC and dissolved oxygen concentration of the O3-treated culture solution. However, iron and manganese among the soluble components have been oxidized by O3 and precipitated, hence these components must be added after the O3 treatment. In spinach culture performed on a culture medium inoculated with Fusarium bacteria, ozone water containing dissolved O3 at 0.8 ppm was flown into a urethane foam medium and vegetable roots. This treatment has resulted in reduction of the number of strains occurred with a wilt symptom below that in the section flown with distilled water. The spinach has grown normally without showing an effect of the ozone water. 15 refs., 10 figs., 3 tabs.

  6. Sterile neutrinos in cosmology

    Science.gov (United States)

    Abazajian, Kevork N.

    2017-11-01

    Sterile neutrinos are natural extensions to the standard model of particle physics in neutrino mass generation mechanisms. If they are relatively light, less than approximately 10 keV, they can alter cosmology significantly, from the early Universe to the matter and radiation energy density today. Here, we review the cosmological role such light sterile neutrinos can play from the early Universe, including production of keV-scale sterile neutrinos as dark matter candidates, and dynamics of light eV-scale sterile neutrinos during the weakly-coupled active neutrino era. We review proposed signatures of light sterile neutrinos in cosmic microwave background and large scale structure data. We also discuss keV-scale sterile neutrino dark matter decay signatures in X-ray observations, including recent candidate ∼3.5 keV X-ray line detections consistent with the decay of a ∼7 keV sterile neutrino dark matter particle.

  7. Charged black lens in de Sitter space

    Science.gov (United States)

    Tomizawa, Shinya

    2018-02-01

    We obtain a charged black lens solution in the five-dimensional Einstein-Maxwell-Chern-Simons theory with a positive cosmological constant. It is shown that the solution obtained here describes the formation of a black hole with the spatial cross section of a sphere from that of the lens space of L (n ,1 ) in five-dimensional de Sitter space.

  8. Lens Model

    DEFF Research Database (Denmark)

    Nash, Ulrik William

    2014-01-01

    Firms consist of people who make decisions to achieve goals. How do these people develop the expectations which underpin the choices they make? The lens model provides one answer to this question. It was developed by cognitive psychologist Egon Brunswik (1952) to illustrate his theory...

  9. [Regret of female sterilization].

    Science.gov (United States)

    Öhman, Malin Charlotta; Andersen, Lars Franch

    2015-11-16

    Regret of sterilization is inversely correlated to age at the time of sterilization. The minimum age for legal sterilization in Denmark has recently been lowered to 18 years. In Denmark surgical refertilization has almost completely been replaced by in vitro fertilization (IVF). In recent literature pregnancy results after surgical refertilization are easily comparable to IVF. Refertilization may in some cases be advantageous to IVF treatment. Women requesting reversal of sterilization should be offered individualized evaluation and differentiated treatment. It is recommended that surgical refertilization is performed at very few centres.

  10. Corneal ring infiltration in contact lens wearers

    Directory of Open Access Journals (Sweden)

    Seyed Ali Tabatabaei

    2017-01-01

    Full Text Available To report a case of atypical sterile ring infiltrates during wearing soft silicone hydrogel contact lens due to poor lens care. A 29-year-old woman presented with complaints of pain, redness, and morning discharge. She was wearing soft silicone hydrogel contact lens previously; her current symptoms began 1 week before presentation. On examination, best-corrected visual acuity was 20/40 in that eye. Slit-lamp examination revealed dense, ring-shaped infiltrate involving both the superficial and deep stromal layers with lucid interval to the limbus, edema of the epithelium, epithelial defect, and vascularization of the superior limbus. Cornea-specific in vivo laser confocal microscopy (Heidelberg Retina Tomograph 2 Rostock Cornea Module, HRT 2-RCM, Heidelberg Engineering GmbH, Dossenheim, Germany revealed Langerhans cells and no sign of Acanthamoeba or fungal features, using lid scraping and anti-inflammatory drops; her vision completely recovered. We reported an atypical case of a sterile corneal ring infiltrate associated with soft contact lens wearing; smear, culture, and confocal microscopy confirmed a sterile inflammatory reaction.

  11. Acanthamoeba, bacterial, and fungal contamination of contact lens storage cases.

    Science.gov (United States)

    Gray, T B; Cursons, R T; Sherwan, J F; Rose, P R

    1995-01-01

    BACKGROUND--Microbial corneal infection is the most serious complication of contact lens wear. Contact lens cases are a recognised potential source of pathogens associated with corneal ulcers. METHODS--This survey established the incidence of protozoal, bacterial, and fungal contact lens case contamination in 101 asymptomatic daily wear cosmetic contact lens wearers from a domiciliary contact lens practice. RESULTS--Eighty two (81%) contact lens cases were found to be contaminated, with 19 (19%) sterile. Of all contact lens cases, 78 (77%) grew bacteria, 24 (24%) fungi, and 20 (20%) protozoa. Acanthamoeba spp were isolated from eight (8%) contact lens cases. Fifty six (55%) contact lens cases yielded mixed bacterial contamination. This is the first contact lens case survey in which hydrogen peroxide disinfection was the major method of contact lens disinfection (75% of subjects) and no home made saline was used. All the contaminating organisms were shown to possess the enzyme catalase that breaks down hydrogen peroxide to oxygen and water. The polymicrobial nature of the biofilms found in many contact lens cases is illustrated electron micrographically. CONCLUSION--Based on data from this and previous studies, the authors conclude with recommendations for contact lens wearers: (1) regular scrubbing of contact lens case interior to disrupt biofilms; (2) exposure of contact lens case to very hot water (> or = 70 degrees C) will kill Acanthamoeba contaminants; (3) allow contact lens case to air dry between uses; (4) if hydrogen peroxide disinfection is preferred, use a two step system; (5) replace contact lens case regularly. Images PMID:7626578

  12. Degradation of chitosan-based materials after different sterilization treatments

    Science.gov (United States)

    San Juan, A.; Montembault, A.; Gillet, D.; Say, J. P.; Rouif, S.; Bouet, T.; Royaud, I.; David, L.

    2012-02-01

    Biopolymers have received in recent years an increasing interest for their potential applications in the field of biomedical engineering. Among the natural polymers that have been experimented, chitosan is probably the most promising in view of its exceptional biological properties. Several techniques may be employed to sterilize chitosan-based materials. The aim of our study was to compare the effect of common sterilization treatments on the degradation of chitosan-based materials in various physical states: solutions, hydrogels and solid flakes. Four sterilization methods were compared: gamma irradiation, beta irradiation, exposure to ethylene oxide and saturated water steam sterilization (autoclaving). Exposure to gamma or beta irradiation was shown to induce an important degradation of chitosan, regardless of its physical state. The chemical structure of chitosan flakes was preserved after ethylene oxide sterilization, but this technique has a limited use for materials in the dry state. Saturated water steam sterilization of chitosan solutions led to an important depolymerization. Nevertheless, steam sterilization of chitosan flakes bagged or dispersed in water was found to preserve better the molecular weight of the polymer. Hence, the sterilization of chitosan flakes dispersed in water would represent an alternative step for the preparation of sterilized chitosan solutions. Alternatively, autoclaving chitosan physical hydrogels did not significantly modify the macromolecular structure of the polymer. Thus, this method is one of the most convenient procedures for the sterilization of physical chitosan hydrogels after their preparation.

  13. Degradation of chitosan-based materials after different sterilization treatments

    International Nuclear Information System (INIS)

    San Juan, A; Montembault, A; Royaud, I; David, L; Gillet, D; Say, J P; Rouif, S; Bouet, T

    2012-01-01

    Biopolymers have received in recent years an increasing interest for their potential applications in the field of biomedical engineering. Among the natural polymers that have been experimented, chitosan is probably the most promising in view of its exceptional biological properties. Several techniques may be employed to sterilize chitosan-based materials. The aim of our study was to compare the effect of common sterilization treatments on the degradation of chitosan-based materials in various physical states: solutions, hydrogels and solid flakes. Four sterilization methods were compared: gamma irradiation, beta irradiation, exposure to ethylene oxide and saturated water steam sterilization (autoclaving). Exposure to gamma or beta irradiation was shown to induce an important degradation of chitosan, regardless of its physical state. The chemical structure of chitosan flakes was preserved after ethylene oxide sterilization, but this technique has a limited use for materials in the dry state. Saturated water steam sterilization of chitosan solutions led to an important depolymerization. Nevertheless, steam sterilization of chitosan flakes bagged or dispersed in water was found to preserve better the molecular weight of the polymer. Hence, the sterilization of chitosan flakes dispersed in water would represent an alternative step for the preparation of sterilized chitosan solutions. Alternatively, autoclaving chitosan physical hydrogels did not significantly modify the macromolecular structure of the polymer. Thus, this method is one of the most convenient procedures for the sterilization of physical chitosan hydrogels after their preparation.

  14. Modular ionizing sterilizer (MIS)

    International Nuclear Information System (INIS)

    Freijo, Jose L.

    1999-01-01

    A transportable device designed to sterilize medical material and wastes by gamma irradiation is described. The sterilizer is formed by three modules: one of the modules contains the gamma source and can be removed to transport and transfer the source, the other modules are designed to introduce and draw out the materials to be irradiated

  15. [Contact lens care and maintenance].

    Science.gov (United States)

    Bloise, L

    2017-04-01

    All contact lenses with replacement schedules longer than daily must be maintained. At each step of their use, the lenses may be contaminated. Contact lens solutions perform the essential functions of cleaning, decontaminating and preserving the lenses to prevent infectious problems and improve wearing comfort. Contact lens contamination essentially comes from hands, cleaning solutions, cases, water and the environment. The pathogenic microorganisms are mainly Gram-negative bacteria, fungi and amoebae. Contact lens deposits may or may not have an organic origin. Their presence increases the risk of infection because they serve as a nutrient matrix for microbes, and they are responsible for wearing discomfort. Contact lens solutions differ in their composition, their mechanism of action and the concentration of the various agents. To prescribe the best lens care system to each wearer and for each material, it is necessary to be very familiar with them. Maintenance is the main cause of discomfort with contact lenses, either through improper use, solution-material incompatibility, or a reaction of the wearer to the components. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  16. Chemical sterilization of allograft dermal tissues.

    Science.gov (United States)

    Phipps, Abigail; Vaynshteyn, Edward; Kowalski, John B; Ngo, Manh-Dan; Merritt, Karen; Osborne, Joel; Chnari, Evangelia

    2017-12-01

    Common terminal sterilization methods are known to alter the natural structure and properties of soft tissues. One approach to providing safe grafts with preserved biological properties is the combination of a validated chemical sterilization process followed by an aseptic packaging process. This combination of processes is an accepted method for production of sterile healthcare products as described in ANSI/AAMI ST67:2011. This article describes the validation of the peracetic acid and ethanol-based (PAAE) chemical sterilization process for allograft dermal tissues at the Musculoskeletal Transplant Foundation (MTF, Edison, NJ). The sterilization capability of the PAAE solution used during routine production of aseptically processed dermal tissue forms was determined based on requirements of relevant ISO standards, ISO 14161:2009 and ISO 14937:2009. The resistance of spores of Bacillus subtilis, Clostridium sporogenes, Mycobacterium terrae, Pseudomonas aeruginosa, Enterococcus faecium, and Staphylococcus aureus to the chemical sterilization process employed by MTF was determined. Using a worst-case scenario testing strategy, the D value was calculated for the most resistant microorganism, Bacillus. The 12D time parameter determined the minimum time required to achieve a SAL of 10 -6 . Microbiological performance qualification demonstrated a complete kill of 10 6 spores at just a quarter of the full cycle time. The validation demonstrated that the PAAE sterilization process is robust, achieves sterilization of allograft dermal tissue to a SAL 10 -6 , and that in combination with aseptic processing secures the microbiological safety of allograft dermal tissue while avoiding structural and biochemical tissue damage previously observed with other sterilization methods such as ionizing irradiation.

  17. [Sterilization and eugenics].

    Science.gov (United States)

    Shasha, Shaul M

    2011-04-01

    The term "eugenics" was coined by Francis Galton in 1883 and was defined as the science of the improvement of the human race by better breeding. "Positive eugenics" referred to methods of encouraging the "most fit" to reproduce more often, while "negative eugenics" was related to ways of discouraging or preventing the "less fit" from reproducing by birth control and sterilization. Many western countries adopted eugenics programs including Britain, Canada, Norway, Australia, Switzerland and others. In Sweden more then 62,000 "unfits" were forcibly sterilized. Many states in the U.S.A. had adopted marriage laws with eugenics criteria including forced sterilization. Approximately 64,000 individuals were sterilized. Eugenics considerations also lay behind the adoption of the Immigration Restriction Act of 1924. The Largest plan on eugenics was adopted by the Nazi regime in Germany. Hundreds of thousands of people, who were viewed as being "unfit", were forcibly sterilized by different methods: Surgical sterilization or castration with severe complications and high mortality rates. X-ray irradiation. The method was suggested by Brack, and tested by Schuman using prisoners in Block No. 10 in Auschwitz and Birkenau. Experiments were also performed by Brack on prisoners using the "window method". "Klauberg method"--injection of irritating materials into the uterus. Experiments were conducted using the plant Caladium Seguinum which was believed to have sterilization and castration properties.

  18. The dangers of distilled water in contact lens maintenance.

    Science.gov (United States)

    Josephson, J E; Caffery, B E

    1988-03-01

    The reports of serious corneal infection associated with hydrogel lens wear prompted us to explore the level of sterility of the distilled water used by lens wearers in our practice. Fifty patients supplied samples of their partially-used distilled water for testing. Of the samples, 12% were found to be contaminated. Five samples of previously unopened distilled water were tested and no growth was found. We recommend that patients do not use distilled water for the care of hydrogel contact lenses. Rather, sterile unit dose or multi-dose (aerosol) nonpreserved, or preserved salines can be used.

  19. Gamma ray induced male sterility mutant in lentil

    International Nuclear Information System (INIS)

    Srivastava, A.; Yadav, A.K.

    2001-01-01

    Full text: Male sterility refers to the failure of pollen grains to bring about effective fertilization, either due to structural default or physiological disfunctioning and has special significance in hybridization programmes. Male steriles have been produced in a number of crop plants like red gram, pigeon pea, mung bean, khesari and lentil. A completely male sterile mutant was isolated in Lens culinaris Medik, after seed treatment with 100 Gy dose of gamma rays. The male sterile mutant showed 100% pollen sterility but was morphologically more vigorous than the parent plants. It showed more branches and its leaves were bigger, more oblong and dark green. The number of flowers borne by the mutant was significantly higher than any other plant of the treatment. The size of the flowers was also increased but the anthers were smaller in size. Pollen grains were few in number, round in shape but empty and did not take up any stain, indicating that normal microsporogenesis had not taken place. This male sterile mutant was used as the female parent and pollinated with pollen of a parent. Four pods with one seed in each were formed indicating that the mutant was female fertile. The seeds were smaller than those of the parent variety and also dark coloured. The mutant showed increased vigour and flower number as compared to parental plants. Lentil is an important pulse crop and induction of variability in its germplasm is necessary for its improvement. Male steriles can be used conveniently in lentil hybridization programmes. (author)

  20. Sterilization by Laparoscopy

    Science.gov (United States)

    ... If pregnancy does occur, the risk of an ectopic pregnancy is higher than in women who did not ... pregnant. Also, the risk of problems, such as ectopic pregnancy, is increased. What are some alternatives to sterilization? ...

  1. Sterilization by gamma irradiation

    International Nuclear Information System (INIS)

    Reyes Frias, L.

    1992-01-01

    Since 1980 the National Institute of Nuclear Research counts with an Industrial Gamma Irradiator, for the sterilization of raw materials and finished products. Through several means has been promoted the use of this technology as alternative to conventional methods of sterilization as well as steam treatment and ethylene oxide. As a result of the made promotion this irradiator has come to its saturation limit being the sterilization irradiation one of the main services that National Institute of Nuclear Research offers to producer enterprises of disposable materials of medical use also of raw materials for the elaboration of cosmetic products and pharmaceuticals as well as dehydrated foods. It is presented the trend to the sterilization service by irradiation showed by the compilation data in a survey made by potential customers. (Author)

  2. Sterilization of space hardware.

    Science.gov (United States)

    Pflug, I. J.

    1971-01-01

    Discussion of various techniques of sterilization of space flight hardware using either destructive heating or the action of chemicals. Factors considered in the dry-heat destruction of microorganisms include the effects of microbial water content, temperature, the physicochemical properties of the microorganism and adjacent support, and nature of the surrounding gas atmosphere. Dry-heat destruction rates of microorganisms on the surface, between mated surface areas, or buried in the solid material of space vehicle hardware are reviewed, along with alternative dry-heat sterilization cycles, thermodynamic considerations, and considerations of final sterilization-process design. Discussed sterilization chemicals include ethylene oxide, formaldehyde, methyl bromide, dimethyl sulfoxide, peracetic acid, and beta-propiolactone.

  3. Contraception Update: Sterilization.

    Science.gov (United States)

    Antell, Karen; Deshmukh, Prium; Brown, Elizabeth J

    2017-11-01

    Female sterilization procedures include postpartum partial salpingectomy via cesarean or minilaparotomy incision, interval laparoscopic procedures, or hysteroscopic placement of microinserts. Rates of failure and serious complications are low and comparable among the various methods. A hysteroscopic procedure requires a 3-month confirmatory hysterosalpingogram before it is considered effective for contraception. Hysteroscopic sterilization has been shown to be associated with a higher reoperation rate than laparoscopic procedures. For male sterilization, vasectomy is a noninvasive and highly effective method. Vasectomy is an outpatient procedure performed under local anesthesia. The procedure requires confirmation of azoospermia with a semen analysis 8 to 16 weeks after the procedure. Patients who are considering sterilization should be counseled about all the available options and the permanent nature of such procedures. Written permission from the American Academy of Family Physicians is required for reproduction of this material in whole or in part in any form or medium.

  4. Auditing radiation sterilization facilities

    Science.gov (United States)

    Beck, Jeffrey A.

    The diversity of radiation sterilization systems available today places renewed emphasis on the need for thorough Quality Assurance audits of these facilities. Evaluating compliance with Good Manufacturing Practices is an obvious requirement, but an effective audit must also evaluate installation and performance qualification programs (validation_, and process control and monitoring procedures in detail. The present paper describes general standards that radiation sterilization operations should meet in each of these key areas, and provides basic guidance for conducting QA audits of these facilities.

  5. Introduction to sterile neutrinos

    Science.gov (United States)

    Volkas, R. R.

    2002-07-01

    Model-building issues raised by the prospect of light sterile neutrinos are discussed in a pedagogical way. I first review the naive proposal that sterile neutrinos be identified with “right handed neutrinos”. A critical discussion of the simple expedient of adding three gauge singlet fermions to the usual minimal standard model matter content is followed by an examination of right handed neutrinos in extended theories. I introduce the terminology of “fully sterile” and “weakly sterile” to classify varieties usually conflated under the sterile neutrino banner. After introducing the concepts of “technical naturalness” and plain “naturalness”, the unbearable lightness of being a sterile neutrino is confronted. This problem is used to motivate mirror neutrinos, whose connection with pairwise maximal mixing is emphasised. Some brief remarks about phenomenology are made throughout. The impossibility of identifying the sole sterile neutrino of the currently favoured 2 + 2 and 3 + 1 phenomenological constructs as a lone gauge singlet fermion added to the minimal standard model is explained. Finally, I remark on the beauty and subtlety of light sterile neutrino cosmology.

  6. Radiation sterilization of medical devices

    International Nuclear Information System (INIS)

    Kaluska, I.; Stuglik, Z.

    1996-01-01

    Overview of sterilization methods of medical devices has been given, with the special stress put on radiation sterilization. A typical validation program for radiation sterilization has been shown and also a comparison of European and ISO standards concerning radiation sterilization has been discussed. (author). 13 refs, 1 fig., 2 tabs

  7. Hysteroscopic Tubal Sterilization

    Science.gov (United States)

    McMartin, K

    2013-01-01

    Background Hysteroscopic tubal sterilization is a minimally invasive alternative to laparoscopic tubal ligation for women who want permanent contraception. The procedures involves non-surgical placement of permanent microinserts into both fallopian tubes. Patients must use alternative contraception for at least 3 months postprocedure until tubal occlusion is confirmed. Compared to tubal ligation, potential advantages of the hysteroscopic procedure are that it can be performed in 10 minutes in an office setting without the use of general or even local anesthesia. Objective The objective of this analysis was to determine the effectiveness and safety of hysteroscopic tubal sterilization compared with tubal ligation for permanent female sterilization. Data Sources A standard systematic literature search was conducted for studies published from January 1, 2008, until December 11, 2012. Review Methods Observational studies, randomized controlled trials (RCTs), systematic reviews and meta-analyses with 1 month or more of follow-up were examined. Outcomes included failure/pregnancy rates, adverse events, and patient satisfaction. Results No RCTs were identified. Two systematic reviews covered 22 observational studies of hysteroscopic sterilization. Only 1 (N = 93) of these 22 studies compared hysteroscopic sterilization to laparoscopic tubal ligation. Two other noncomparative case series not included in the systematic reviews were also identified. In the absence of comparative studies, data on tubal ligation were derived for this analysis from the CREST study, a large, multicentre, prospective, noncomparative observational study in the United States (GRADE low). Overall, hysteroscopic sterilization is associated with lower pregnancy rates and lower complication rates compared to tubal ligation. No deaths have been reported for hysteroscopic sterilization. Limitations A lack of long-term follow-up for hysteroscopic sterilization and a paucity of studies that directly

  8. Ultraviolet radiation for the sterilization of contact lenses.

    Science.gov (United States)

    Gritz, D C; Lee, T Y; McDonnell, P J; Shih, K; Baron, N

    1990-01-01

    Two sources of ultraviolet (UV) radiation with peak wavelengths in the UV-C or UV-B ranges were compared for their ability to sterilize contact lenses infected with Pseudomonas aeruginosa, Streptococcus pneumoniae, Acanthamoeba castellani, Candida albicans, and Aspergillus niger. Also examined was the effect of prolonged UV light exposure on soft and rigid gas permeable (RGP) contact lenses. The UV-C lamp (253.7 nm, 250 mW/cm2 at 1 cm) was germicidal for all organisms within 20 minutes but caused destruction of the soft lens polymers within 6 hours of cumulative exposure. UV-C caused damage to RGP lenses in less than 100 hours. The UV-B lamp (290-310 nm, 500 mW/cm2 at 1 cm) was germicidal for all organisms tested (except Aspergillus) with a 180-minute exposure and caused less severe changes in the soft lens polymers than did the UV-C lamp, although cumulative exposure of 300 hours did substantially weaken the soft lens material. RGP materials were minimally affected by exposure to 300 hours of UV-B. Ultraviolet light is an effective germicidal agent but is injurious to soft lens polymers; its possible utility in the sterilization of RGP lenses and lens cases deserves further study.

  9. Ultraviolet radiation for the sterilization of contact lenses

    International Nuclear Information System (INIS)

    Gritz, D.C.; Lee, T.Y.; McDonnell, P.J.; Shih, K.; Baron, N.

    1990-01-01

    Two sources of ultraviolet (UV) radiation with peak wavelengths in the UV-C or UV-B ranges were compared for their ability to sterilize contact lenses infected with Pseudomonas aeruginosa, Streptococcus pneumoniae, Acanthamoeba castellani, Candida albicans, and Aspergillus niger. Also examined was the effect of prolonged UV light exposure on soft and rigid gas permeable (RGP) contact lenses. The UV-C lamp (253.7 nm, 250 mW/cm2 at 1 cm) was germicidal for all organisms within 20 minutes but caused destruction of the soft lens polymers within 6 hours of cumulative exposure. UV-C caused damage to RGP lenses in less than 100 hours. The UV-B lamp (290-310 nm, 500 mW/cm2 at 1 cm) was germicidal for all organisms tested (except Aspergillus) with a 180-minute exposure and caused less severe changes in the soft lens polymers than did the UV-C lamp, although cumulative exposure of 300 hours did substantially weaken the soft lens material. RGP materials were minimally affected by exposure to 300 hours of UV-B. Ultraviolet light is an effective germicidal agent but is injurious to soft lens polymers; its possible utility in the sterilization of RGP lenses and lens cases deserves further study

  10. Ultraviolet radiation for the sterilization of contact lenses

    Energy Technology Data Exchange (ETDEWEB)

    Gritz, D.C.; Lee, T.Y.; McDonnell, P.J.; Shih, K.; Baron, N. (Univ. of Southern California School of Medicine, Los Angeles (USA))

    1990-10-01

    Two sources of ultraviolet (UV) radiation with peak wavelengths in the UV-C or UV-B ranges were compared for their ability to sterilize contact lenses infected with Pseudomonas aeruginosa, Streptococcus pneumoniae, Acanthamoeba castellani, Candida albicans, and Aspergillus niger. Also examined was the effect of prolonged UV light exposure on soft and rigid gas permeable (RGP) contact lenses. The UV-C lamp (253.7 nm, 250 mW/cm2 at 1 cm) was germicidal for all organisms within 20 minutes but caused destruction of the soft lens polymers within 6 hours of cumulative exposure. UV-C caused damage to RGP lenses in less than 100 hours. The UV-B lamp (290-310 nm, 500 mW/cm2 at 1 cm) was germicidal for all organisms tested (except Aspergillus) with a 180-minute exposure and caused less severe changes in the soft lens polymers than did the UV-C lamp, although cumulative exposure of 300 hours did substantially weaken the soft lens material. RGP materials were minimally affected by exposure to 300 hours of UV-B. Ultraviolet light is an effective germicidal agent but is injurious to soft lens polymers; its possible utility in the sterilization of RGP lenses and lens cases deserves further study.

  11. Sterilization: A Review and Update.

    Science.gov (United States)

    Moss, Chailee; Isley, Michelle M

    2015-12-01

    Sterilization is a frequently used method of contraception. Female sterilization is performed 3 times more frequently than male sterilization, and it can be performed immediately postpartum or as an interval procedure. Methods include mechanical occlusion, coagulation, or tubal excision. Female sterilization can be performed using an abdominal approach, or via laparoscopy or hysteroscopy. When an abdominal approach or laparoscopy is used, sterilization occurs immediately. When hysteroscopy is used, tubal occlusion occurs over time, and additional testing is needed to confirm tubal occlusion. Comprehensive counseling about sterilization should include discussion about male sterilization (vasectomy) and long-acting reversible contraceptive methods. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Cosmological and astrophysical implications of sterile neutrinos

    Science.gov (United States)

    Petraki, Kalliopi

    The discovery of neutrino masses suggests that the Standard Model should be supplemented with new gauge-singlet fermions, often called sterile neutrinos. The interplay among the new couplings introduced in the Standard Model can accommodate the neutrino oscillation data for a variety of choices: the new particles can be extremely heavy and practically unobservable, or they can be light, in which case they can solve several long-standing puzzles. It has been shown, for example, that sterile neutrinos in some range of masses can account for dark matter, their emission from a supernova can explain pulsar kicks, arid their decays can play an important role in the formation of the first stars. Though indirect, these clues indicate that sterile neutrinos can be the minimal solution to a variety of unsolved problems. This emphasizes the importance of investigating further the consequences of these new degrees of freedom for cosmology and astrophysics. In this dissertation, I explore the possible role of sterile neutrinos of different mass scales in some cosmological and astrophysical phenomena. A minimal extension of the Higgs sector of the Standard Model, with a gauge- singlet boson coupled to sterile neutrinos, can provide a consistent framework for the theory of neutrino masses, and can produce a relic population of keV sterile neutrinos via decays of the singlet Higgs. The latter can account for the dark matter of the universe. The mechanism operates around the electroweak scale, and has interesting consequences for the electroweak phase transition. Relic sterile neutrinos produced via decays at the electroweak scale constitute colder dark matter than those produced via other previously suggested mechanisms. The primordial thermal content of dark matter has important implications for the formation of cosmic structures, such as clusters and galaxies. The assessment of the relevant properties suggests that sterile neutrinos produced at the electroweak scale are a

  13. LENS: Science Scope and Development Stages

    Science.gov (United States)

    Vogelaar, R. Bruce

    2013-04-01

    The Low-Energy Neutrino Spectroscopy (LENS) experiment will resolve the solar metallicity question via measurement of the CNO neutrino flux, as well as test the predicted equivalence of solar luminosity as measured by photon versus neutrinos. The LENS detector uses charged-current interaction of neutrinos on Indium-115 (loaded in a scintillator, InLS) to reveal the complete solar neutrino spectrum. LENS's optically segmented 3D lattice geometry achieves precise time and spatial resolution and unprecedented background rejection and sensitivity for low-energy neutrino events. This first-of-a-kind lattice design is also suited for a range of other applications where high segmentation and large light collection are required (eg: sterile neutrinos with sources, double beta decay, and surface detection of reactor neutrinos). The physics scope, detector design, and logic driving the microLENS and miniLENS prototyping stages will be presented. The collaboration is actively running programs; building, operating, developing, and simulating these prototypes using the Kimballton Underground Research Facility (KURF). New members are welcome to the LENS Collaboration, and interested parties should contact R. Bruce Vogelaar.

  14. sensitive genic male sterile (PGMS) rice

    African Journals Online (AJOL)

    user

    2011-04-18

    Apr 18, 2011 ... phosphate buffered solution; TEM, transmission electron microscope; CMS, cytoplasmic male sterile; FPR, first photo reaction; SPR, second photo reaction. production of cytotoxins which instigate apoptosis. For example in Caenorhabditis elegans, the ced genes code for cystein proteases Ced-3 and Ced-4 ...

  15. Tear film physiology and contact lens wear. II. Contact lens-tear film interaction.

    Science.gov (United States)

    Holly, F J

    1981-04-01

    The successful fitting of contact lenses requires the practitioner to take into account many properties of the specific lens type used but the practitioner must also understand patient factors including tear properties, use of appropriate solutions, procedures for lens cleaning, and efficiency of blinking. Selection of appropriate patients, selection of lens type, proper fitting, good maintenance, and training and monitoring of patients increase the probability of achieving success.

  16. The effectiveness of soft contact lens disinfection systems against Acanthamoeba on the lens surface.

    Science.gov (United States)

    Liedel, K K; Begley, C G

    1996-03-01

    This investigation compared the efficacy of three widely used contact lens disinfection systems against an ocular isolate of Acanthamoeba polyphaga. Twenty-seven worn Ciba NewVues lenses were quartered, heat sterilized and inoculated with Acanthamoeba. Lens quarters were then randomly assigned to three experimental groups, with Group A lenses exposed to cleaner and saline rinse only, Group B to disinfection only, and Group C to both cleaner and disinfection. One quarter of each lens served as a control and the other three quarters were experimental. Quantification of viable Acanthamoeba remaining on the lens was performed after each step of the disinfection process. Group A lenses showed no significant difference between the treatments, or the treatments and the control. Group B lenses demonstrated a significant difference (p = 0.0001) between the treatments and the control. In Group C (cleaning and disinfection), the control lens quarters were significantly different (p = 0.037) from the experimental group, but there was no significant difference between the treatments. All three disinfection regimens were very effective in reducing the number of viable Acanthamoeba on the contact lens surface. In the absence of proper cleaning (Group B), AOSept was the most effective of the three. These results also show the importance of thoroughly rubbing the contact lens surface to decrease the number of Acanthamoeba.

  17. Voluntary sterilization in Britain.

    Science.gov (United States)

    Jackson, L N

    1968-01-01

    Only recently has the value and importance of sterilization as an effective method of birth control come to be widely recognized in Britian. Credit for this recognition is largely due to the initiative of Dr. C. P. Blacker, chairman of the Simon Population Trust. The Trust's sterilization project was conceived by him and, heralded by an article in The Lancet on 30 April 1966, was launched at a press conference in London in May of that year. Since then the Project has gone from strength to strength. It first function was to make known how voluntary sterilization can help to solve or prevent family problems and to facilitate its practice in Britian. The project has also been concerned to correct the erroneous belief, still held by a dwindling number of medical and law persons, that sterilization is against the law. A prerequisite was to enlist cooperative surgeons all over the country, whose names are now being sent on request to family doctors wishing to refer men for sterilization. The project is concerned mainly with male, rather than female, sterilization. The reason for this is that, when the relative simplicity of vasectomy as compared with tubal ligation is explained to them most couples choose vasectomy. Information about sterilization is supplied not only to applicants but also to university and hospital authorities, surgeons, health and welfare workers, family planning clinics. Forms of consent are provided for the couple concerned, and a follow-up inquiry is being conducted on a substantial scale among men who have been sterilized through the agency of the Project. Though this inquiry is far from complete, replies so far received indicate almost universal satisfaction with the results of the operation. Indeed, with the fear of unwanted pregnancies removed, many couples report that marital harmony is increased. It is known that at least 2000 men have already been sterilized through the mediation of this Project and, as family doctors become increasingly

  18. Contact lens in keratoconus

    Directory of Open Access Journals (Sweden)

    Varsha M Rathi

    2013-01-01

    Full Text Available Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP lenses, soft and soft toric lenses, piggy back contact lenses (PBCL, hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the English language with the keywords keratoconus and various contact lenses such as Rose k lens, RGP lens, hybrid lens, scleral lens and PBCL.

  19. Contact lens in keratoconus

    Science.gov (United States)

    Rathi, Varsha M; Mandathara, Preeji S; Dumpati, Srikanth

    2013-01-01

    Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP) lenses, soft and soft toric lenses, piggy back contact lenses (PBCL), hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the English language with the keywords keratoconus and various contact lenses such as Rose k lens, RGP lens, hybrid lens, scleral lens and PBCL. PMID:23925325

  20. Contraception or eugenics? Sterilization and "mental retardation" in the 1970s and 1980s.

    Science.gov (United States)

    Ladd-Taylor, Molly

    2014-01-01

    Nonconsensual sterilization is usually seen as the by-product of a classist and racist society; disability is ignored. This article examines the 1973 sterilization of two young black girls from Alabama and other precedent-setting court cases involving the sterilization of "mentally retarded" white women to make disability more central to the historical analysis of sterilization. It analyzes the concept of mental retardation and the appeal of a surgical solution to birth control, assesses judicial deliberations over the "right to choose" contraceptive sterilization when the capacity to consent is in doubt, and reflects on the shadow of eugenics that hung over the sterilization debate in the 1970s and 1980s.

  1. Audits of radiation sterilization facilities

    International Nuclear Information System (INIS)

    Kelkar, Prabhakar M.

    2001-01-01

    Johnson and Johnson is the world leader in sterilization science and technology. A special group of scientists and technologists are engaged in the development of new methods of sterilization, worldwide monitoring of sterilization processes, equipment and approvals for all types of sterilization processes. Kilmer Conference in the alternate year for the benefit of all those involved in improvement in sterilization science is held. Cobalt-60 gamma radiation for sterilization of medical products on commercial scale is used. This kind of mammoth task can only be achieved through systematic method of planning, auditing, expert review and approval of facilities

  2. Evaluation of Effects of Sterilization on Mechanical Properties of Orthodontic Wires

    Directory of Open Access Journals (Sweden)

    Sridhar Kannan

    2012-01-01

    Results: Dry heat sterilization, autoclave, 2% glutaraldehyde solution had no effect on ultimate tensile strength, 0.1% yield strength, modulus of elasticity and percentage elongation of stainless steel and elgiloy wires. Tensile strength and yield strength of Nitinol and b-titanium wires together with percentage elongation of b-titanium wires significantly increased following dry heat sterilization and autoclave. No detrimental effects on properties of wires were observed. These sterilization procedures could be safely recommended for sterilization of orthodontic wires.

  3. Heat sterilization of wood

    Science.gov (United States)

    Xiping Wang

    2010-01-01

    Two important questions should be considered in heat sterilizing solid wood materials: First, what temperature–time regime is required to kill a particular pest? Second, how much time is required to heat the center of any wood configuration to the kill temperature? The entomology research on the first question has facilitated the development of international standards...

  4. MINOS Sterile Neutrino Search

    Energy Technology Data Exchange (ETDEWEB)

    Koskinen, David Jason [Univ. College London, Bloomsbury (United Kingdom)

    2009-02-01

    The Main Injector Neutrino Oscillation Search (MINOS) is a long-baseline accelerator neutrino experiment designed to measure properties of neutrino oscillation. Using a high intensity muon neutrino beam, produced by the Neutrinos at Main Injector (NuMI) complex at Fermilab, MINOS makes two measurements of neutrino interactions. The first measurement is made using the Near Detector situated at Fermilab and the second is made using the Far Detector located in the Soudan Underground laboratory in northern Minnesota. The primary goal of MINOS is to verify, and measure the properties of, neutrino oscillation between the two detectors using the v μ→ Vτ transition. A complementary measurement can be made to search for the existence of sterile neutrinos; an oft theorized, but experimentally unvalidated particle. The following thesis will show the results of a sterile neutrino search using MINOS RunI and RunII data totaling ~2.5 x 1020 protons on target. Due to the theoretical nature of sterile neutrinos, complete formalism that covers transition probabilities for the three known active states with the addition of a sterile state is also presented.

  5. Sterilization of Native Americans

    Science.gov (United States)

    Dillingham, Brint

    1977-01-01

    The U.S. State Department's Agency for International Development (AID) is spending more than $143 million this year for population control measures in over 70 nations around the world and it is estimated that as much as $10 million was spent in one year for surgical sterilization procedures. (JC)

  6. Radiation studies in Lens culinaris

    International Nuclear Information System (INIS)

    Sinha, S.S.N.

    1977-01-01

    Estimation of chromosomal aberrations in flowers of Lens culinaris according to their sequence of development in the plants at 4, 8 and 12 Kr in the M 1 generation, showed that the later formed flowers had smaller percentages of cells with aberrations than those developed earlier. It is suggested that this may be the result of competition between more damaged and less damaged cells during the development of the shoot. There is consequently a decrease of sterility in successive flowers. The numbers of karyotypes taking part in the formation of lower and uppermost flowers were estimated cytologically at 4, 8 and 12 Kr. It was found that more karyotypes were involved in the formation of the lower flowers than in the upper ones. It appeared that at lower doses larger numbers of karyotypes were taking part in the formation of the chimaera than at higher doses. (auth.)

  7. Microbial contamination of contact lens storage cases and domestic tap water of contact lens wearers.

    Science.gov (United States)

    Üstüntürk, Miray; Zeybek, Zuhal

    2012-11-01

    Contact lenses have been widely used as an alternative to spectacles both in developed and developing countries. However, under certain circumstances, adverse responses can occur during contact lens wear and several microorganisms--including bacteria, fungi, and free living amoebae--can cause several eye infections in wearers. Extended wear of contact lenses is the major risk factor of eye infections such as microbial keratitis, besides contaminated contact lens storage case, contaminated lens care solutions, and inaccurate contact lens handling. In this study, we collected contact lens storage case and domestic tap water samples from 50 asymptomatic contact lens wearers. We determined that total aerobic mesophilic bacteria were isolated in 45 (90 %), Gram negative rod bacteria were isolated in 20 (40 %), Pseudomonas spp. were isolated in 2 (4 %) and fungi were isolated in 18 (36 %) out of 50 contact lens storage cases. Free living amoebae were not detected in investigated contact lens storage cases. At the same time, out of 50, total aerobic mesophilic bacteria were isolated in 34 (68 %), fungi were isolated in 15 (30 %) and free living amoebae were isolated in 15 (30 %) domestic tap water samples. No Gram-negative rod bacteria and Pseudomonas spp. were detected in investigated water samples. Two contact lens case samples and two tap water samples were excluded from the analysis for Pseudomonas spp. for technical reasons. According to our findings, inadequate contact lens maintenance during lens wear may result in the contamination of contact lens storage cases. This situation can lead to severe eye infections in contact lens wearers over time.

  8. Panoramic lens applications revisited

    Science.gov (United States)

    Thibault, Simon

    2008-04-01

    During the last few years, innovative optical design strategies to generate and control image mapping have been successful in producing high-resolution digital imagers and projectors. This new generation of panoramic lenses includes catadioptric panoramic lenses, panoramic annular lenses, visible/IR fisheye lenses, anamorphic wide-angle attachments, and visible/IR panomorph lenses. Given that a wide-angle lens images a large field of view on a limited number of pixels, a systematic pixel-to-angle mapping will help the efficient use of each pixel in the field of view. In this paper, we present several modern applications of these modern types of hemispheric lenses. Recently, surveillance and security applications have been proposed and published in Security and Defence symposium. However, modern hemispheric lens can be used in many other fields. A panoramic imaging sensor contributes most to the perception of the world. Panoramic lenses are now ready to be deployed in many optical solutions. Covered applications include, but are not limited to medical imaging (endoscope, rigiscope, fiberscope...), remote sensing (pipe inspection, crime scene investigation, archeology...), multimedia (hemispheric projector, panoramic image...). Modern panoramic technologies allow simple and efficient digital image processing and the use of standard image analysis features (motion estimation, segmentation, object tracking, pattern recognition) in the complete 360° hemispheric area.

  9. Effect of delayed sterilization on the production of intravenous fluids ...

    African Journals Online (AJOL)

    % (w/v) dextrose solution was studied. The 5% (w/v) dextrose was prepared with distilled water. The solution was inoculated with a laboratory isolate of Escherichia coli and thereafter divided into two: Solutions A and B. Sample A was sterilized ...

  10. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... lens because they can be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, ... Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume Contacts May Contain Chemicals Harmful to Eyes ...

  11. 21 CFR 880.6850 - Sterilization wrap.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Sterilization wrap. 880.6850 Section 880.6850 Food... § 880.6850 Sterilization wrap. (a) Identification. A sterilization wrap (pack, sterilization wrapper... sterilized by a health care provider. It is intended to allow sterilization of the enclosed medical device...

  12. Sterile neutrino anarchy

    Science.gov (United States)

    Heeck, Julian; Rodejohann, Werner

    2013-02-01

    Lepton mixing, which requires physics beyond the Standard Model, is surprisingly compatible with a minimal, symmetryless and unbiased approach, called anarchy. This contrasts with highly involved flavor symmetry models. On the other hand, hints for light sterile neutrinos have emerged from a variety of independent experiments and observations. If confirmed, their existence would represent a groundbreaking discovery, calling for a theoretical interpretation. We discuss anarchy in the two-neutrino eV-scale seesaw framework. The distributions of mixing angles and masses according to anarchy are in agreement with global fits for the active and sterile neutrino parameters. Our minimal and economical scenario predicts the absence of neutrinoless double beta decay and one vanishing neutrino mass, and can therefore be tested in future experiments.

  13. Abortion and sterilization.

    Science.gov (United States)

    Steele, S J

    1970-01-01

    This discusses activities current in England under the abortion law of April 1968. In England and Wales in 1969 there were 54,013 recorded abortions and 15 related deaths. Since then both the number of deaths and the number of abortions have been increasing. This abortion increase is partly attributed to the adverse publicity regarding the pill which has caused many women to give up oral contraceptives. Complications have included incomplete removal of the products of conception, sepsis, hemorrhage, and perforation of the uterus. There have been wide variation in interpretations of the law by different hospitals and staffs. Sterilization operations are being done in increasing number for both men and women. Carefully worded consent forms are now in use to insure patient understanding and consent. Psychological changes may follow sterilization, but are relatively uncommon. Physicians should do all possible to help women avoid unwanted pregnancies and thereby reduce the demand for termination.

  14. Genetically conditioned male sterility

    International Nuclear Information System (INIS)

    Gottschalk, W.

    1976-01-01

    A survey is given of two different types of genetically controlled male sterility in higher plants. 'Functional' male sterility is due to the action of mutated genes causing a misdifferentiation of the growing points in different specific ways. Under the influence of the genes of this group either the stamens or the archespore tissues are not differentiated. In other mutants functionable male germ cells are produced but cannot be used for fertilizing the egg cells because the anthers remain closed or anthers and stigma become spatially separated from each other. Other genes of the group are responsible for the transformation of stamens into carpels, i.e. for a change of the hermaphrodite flower into a unisexually female one. A second type of male sterility is due to the action of ms genes influencing the course of micro-sporogenesis directly. They cause the breakdown of this process in a specific meiotic stage characteristic for each gene of the group. This breakdown is introduced by the degeneration of PMCs, microspores, or pollen grains preventing the production of male germ cells. The female sex organs remain uninfluenced. (author)

  15. Contractual considerations in contact lens practice.

    Science.gov (United States)

    Classé, J G

    1986-03-01

    The use of forms in contact lens practice can save time, promote patient education, and reduce the opportunity for legal or economic disputes. The most commonly employed forms are those for contact lens fitting agreements, instructions for care and maintenance of lenses, prepaid service agreements, clinical investigations of investigatory lenses or solutions, and for extended wear patients. Sample forms are utilized for purposes of illustration.

  16. Tube entrance lens focus control

    Science.gov (United States)

    Weisser, D. C.; Fifield, L. K.; Kitchen, T. F. G.; Tunningley, T. B.; Lobanov, N. R.; Muirhead, A. G.

    2013-02-01

    The entrance of the accelerator tube in a large electrostatic accelerator imposes a strong lens that dominates the beam optics. The magnification of the lens is large because of the low injection energy, the high voltage gradient of the acceleration tube and the long distance to the terminal. In the absence of the acceleration, the magnification would produce an unacceptably large beam spot at the terminal. The tyranny of the lens is especially irksome when the accelerator is required to operate at a lower terminal voltage than the one corresponding to the nominal gradient at high voltage. One way around the difficulty, used in NEC Pelletron accelerators, is to insert a series of nylon and steel rods that short together units of the acceleration structure at the terminal leaving the ones near the entrance close to the nominal gradient for optimum transmission. This operation takes time and risks the loss of insulating gas. Another alternative used in the 25URC at Oak Ridge National Laboratory, is to focus the beam at the tube entrance, substantially diluting the effect of the entrance lens. The beam then diverges and so requires an additional lens part way to the terminal. This solution is only partially effective and still necessitates use of shorting rods for low voltage operation. The fact that these elaborate strategies are used is evidence that the alternative of lowering the injection energy as the terminal voltage is lowered imposes enough problems that it is not used in practice. We have modeled a solution that controls the voltage gradient at the tube entrance using an external power supply. This not only maintains the focusing effect of the lens but provides the opportunity to tune the beam by adjusting the entrance lens. A 150 kV power supply outside the pressure vessel feeds a controllable voltage through a high voltage feed-through to the fifth electrode of the accelerator tube. Thus 150 kV on this electrode creates the nominal gradient of 30 kV per

  17. Electron beam sterilization for dishes

    International Nuclear Information System (INIS)

    Deren, Wang; Meizhen, Fang

    1995-01-01

    Modern biological science often needs various fine strike devices which are often made from non-toxic transparent plastic. The application of high temperature steam to the sterilization as a traditional methods often causes deformation and colour change. When chemicals are applied to the sterilization residure of chemical grain often causes toxicity. Only application of radiation to the sterilization can overcome this faults and carry out with sterility assurance at room temperature. In this research 1.3 MeV electron beam coming from Model JJ-2 accelerator was applied for sterilization to 96-well tissue culture plates. After clean packaging the plates were irradiated with 31.7 XGy and operational voltage 1.3 MeV and 100 μA on the PY device. Repeated tests demonstrate that the products are sterile. The output is 2 x 10 5 pieces for each year. (author)

  18. Validation of radiation sterilization process

    International Nuclear Information System (INIS)

    Kaluska, I.

    2007-01-01

    The standards for quality management systems recognize that, for certain processes used in manufacturing, the effectiveness of the process cannot be fully verified by subsequent inspection and testing of the product. Sterilization is an example of such a process. For this reason, sterilization processes are validated for use, the performance of sterilization process is monitored routinely and the equipment is maintained according to ISO 13 485. Different aspects of this norm are presented

  19. Sterilization in the United States

    Science.gov (United States)

    Bartz, Deborah; Greenberg, James A

    2008-01-01

    Unintended pregnancies are expensive for patients and for society in terms of medical costs, the cost of caring for more children, and the cost to personal and professional goals. Sterilization is the most common contraceptive method utilized by couples in the United States. Given technological advances over the past few decades, male and female surgical sterilization has become a safe, convenient, easy, and highly effective birth control method for the long term. This article reviews current male and female sterilization options. PMID:18701927

  20. Sterilizing insects with ionizing radiation

    International Nuclear Information System (INIS)

    Bakri, A.; Mehta, K.; Lance, D.R.

    2005-01-01

    Exposure to ionizing radiation is currently the method of choice for rendering insects reproductively sterile for area-wide integrated pest management (AW-IPM) programmes that integrate the sterile insect technique (SIT). Gamma radiation from isotopic sources (cobalt-60 or caesium-137) is most often used, but high-energy electrons and X-rays are other practical options. Insect irradiation is safe and reliable when established safety and quality-assurance guidelines are followed. The key processing parameter is absorbed dose, which must be tightly controlled to ensure that treated insects are sufficiently sterile in their reproductive cells and yet able to compete for mates with wild insects. To that end, accurate dosimetry (measurement of absorbed dose) is critical. Irradiation data generated since the 1950s, covering over 300 arthropod species, indicate that the dose needed for sterilization of arthropods varies from less than 5 Gy for blaberid cockroaches to 300 Gy or more for some arctiid and pyralid moths. Factors such as oxygen level, and insect age and stage during irradiation, and many others, influence both the absorbed dose required for sterilization and the viability of irradiated insects. Consideration of these factors in the design of irradiation protocols can help to find a balance between the sterility and competitiveness of insects produced for programmes that release sterile insects. Many programmes apply 'precautionary' radiation doses to increase the security margin of sterilization, but this overdosing often lowers competitiveness to the point where the overall induced sterility in the wild population is reduced significantly. (author)

  1. REFRACTIVE NEUTRON LENS

    OpenAIRE

    Petrov, P. V.; Kolchevsky, N. N.

    2013-01-01

    Compound concave refractive lenses are used for focusing neutron beam. Investigations of spectral and focusing properties of a refractive neutron lens are presented. Resolution of the imaging system on the base of refractive neutron lenses depends on material properties and parameters of neutron source. Model of refractive neutron lens are proposed. Results of calculation diffraction resolution and focal depth of refractive neutron lens are discussed.

  2. Contact lens in keratoconus

    OpenAIRE

    Rathi, Varsha M; Mandathara, Preeji S; Dumpati, Srikanth

    2013-01-01

    Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP) lenses, soft and soft toric lenses, piggy back contact lenses (PBCL), hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the En...

  3. Energy analysis in sterilization process of food

    International Nuclear Information System (INIS)

    Lee, Dong Sun; Pyun, Yu Ryang

    1986-01-01

    A procedure was developed for predicting energy consumption of batch type thermal processing of food. From mass and energy balance equations various energy usages or losses were estimated for steam sterilization of model food system in No.301-7 can (Φ74.1 x 113.0mm) at three different temperatures. Selected models were 5 % bentonite solution for conductive food and tap water for convective food. Total steam or energy consumption was higher at 110 deg C than at two other higher temperatures (121 deg C and 130 deg C). High energy consumption at low sterilization temperature was mainly due to high bleeding steam energy and convective and radiative heat losses. Thermal energy efficiency was also disscussed. (Author)

  4. Sterilization of Extracted Human Teeth.

    Science.gov (United States)

    Pantera, Eugene A., Jr.; Schuster, George S.

    1990-01-01

    At present, there is no specific recommendation for sterilization of extracted human teeth used in dental technique courses. The purpose of this study was to determine whether autoclaving would be effective in the sterilization of extracted teeth without compromising the characteristics that make their use in clinical simulations desirable. (MLW)

  5. Conditional sterility in plants

    Science.gov (United States)

    Meagher, Richard B.; McKinney, Elizabeth; Kim, Tehryung

    2010-02-23

    The present disclosure provides methods, recombinant DNA molecules, recombinant host cells containing the DNA molecules, and transgenic plant cells, plant tissue and plants which contain and express at least one antisense or interference RNA specific for a thiamine biosynthetic coding sequence or a thiamine binding protein or a thiamine-degrading protein, wherein the RNA or thiamine binding protein is expressed under the regulatory control of a transcription regulatory sequence which directs expression in male and/or female reproductive tissue. These transgenic plants are conditionally sterile; i.e., they are fertile only in the presence of exogenous thiamine. Such plants are especially appropriate for use in the seed industry or in the environment, for example, for use in revegetation of contaminated soils or phytoremediation, especially when those transgenic plants also contain and express one or more chimeric genes which confer resistance to contaminants.

  6. The Sterile Insect Technique

    International Nuclear Information System (INIS)

    Kiragu, J.

    2006-01-01

    Insect pests have caused an increasing problem in agriculture and human health through crop losses and disease transmission to man and livestock. Intervention to ensure food security and human health has relied on Integrated Pest Management (IPM) strategies to keep the pests population below economic injury levels. IPM integrate a variety of methods, but there has been over-reliance on chemical control following the discovery of insecticidal properties of DDT. It is now realized that, maintaining pest populations at controlled levels is unsustainable and eradication options is now being considered. Although the Sterile Insect Technique(SIT) could be used for insect suppression, it is gaining favour in the elimination (eradication) of the target pest population through Areawide-based IPM (Author)

  7. Ethylene Oxide Gaseous Sterilization

    Science.gov (United States)

    Ernst, Robert R.; Shull, James J.

    1962-01-01

    The duration of the equilibration period between admission of water vapor and subsequent introduction of gaseous ethylene oxide to an evacuated sterilizer chamber was studied with respect to its effect on the inactivation of spores of Bacillus subtilis var. niger under simulated practical conditions. Introduction of a water-adsorbing cotton barrier between the spores and an incoming gas mixture of water vapor and ethylene oxide caused a marked increase in the observed thermochemical death time of the spore populations. This effect was negated by admission of water vapor one or more minutes prior to introduction of ethylene oxide gas. Increases in temperature and relative humidity of the system promoted passage of water vapor through the cotton barriers and diminished their effect. PMID:13890660

  8. Thermalizing Sterile Neutrino Dark Matter

    Science.gov (United States)

    Hansen, Rasmus S. L.; Vogl, Stefan

    2017-12-01

    Sterile neutrinos produced through oscillations are a well motivated dark matter candidate, but recent constraints from observations have ruled out most of the parameter space. We analyze the impact of new interactions on the evolution of keV sterile neutrino dark matter in the early Universe. Based on general considerations we find a mechanism which thermalizes the sterile neutrinos after an initial production by oscillations. The thermalization of sterile neutrinos is accompanied by dark entropy production which increases the yield of dark matter and leads to a lower characteristic momentum. This resolves the growing tensions with structure formation and x-ray observations and even revives simple nonresonant production as a viable way to produce sterile neutrino dark matter. We investigate the parameters required for the realization of the thermalization mechanism in a representative model and find that a simple estimate based on energy and entropy conservation describes the mechanism well.

  9. Sterile Endophthalmitis after Intravitreal Injections

    Directory of Open Access Journals (Sweden)

    Joaquín Marticorena

    2012-01-01

    Full Text Available Sterile endophthalmitis appears as an infrequent complication of intravitreal injections and seems to develop mainly in the context of the off-label use of drugs that have not been conceived for intravitreous administration. The aetiology of sterile endophthalmitis, independently of the administered drug, remains uncertain and a multifactorial origin cannot be discarded. Sterile inflammation secondary both to intravitreal triamcinolone acetonide and to intravitreal bevacizumab share many characteristics such as the acute and painless vision loss present in the big majority of the cases. Dense vitreous opacity is a common factor, while anterior segment inflammation appears to be mild to moderate. In eyes with sterile endophthalmitis, visual acuity improves progressively as the intraocular inflammation reduces without any specific treatment. If by any chance the ophthalmologist is not convinced by the sterile origin of the inflammation, this complication must be treated as an acute endophthalmitis because of the devastating visual prognosis of this intraocular infection in the absence of therapy.

  10. Thermalizing Sterile Neutrino Dark Matter.

    Science.gov (United States)

    Hansen, Rasmus S L; Vogl, Stefan

    2017-12-22

    Sterile neutrinos produced through oscillations are a well motivated dark matter candidate, but recent constraints from observations have ruled out most of the parameter space. We analyze the impact of new interactions on the evolution of keV sterile neutrino dark matter in the early Universe. Based on general considerations we find a mechanism which thermalizes the sterile neutrinos after an initial production by oscillations. The thermalization of sterile neutrinos is accompanied by dark entropy production which increases the yield of dark matter and leads to a lower characteristic momentum. This resolves the growing tensions with structure formation and x-ray observations and even revives simple nonresonant production as a viable way to produce sterile neutrino dark matter. We investigate the parameters required for the realization of the thermalization mechanism in a representative model and find that a simple estimate based on energy and entropy conservation describes the mechanism well.

  11. Electrolytic silver ion cell sterilizes water supply

    Science.gov (United States)

    Albright, C. F.; Gillerman, J. B.

    1968-01-01

    Electrolytic water sterilizer controls microbial contamination in manned spacecraft. Individual sterilizer cells are self-contained and require no external power or control. The sterilizer generates silver ions which do not impart an unpleasant taste to water.

  12. Radio-sterilization and processing of frozen human skin

    International Nuclear Information System (INIS)

    Zarate S, Herman; Aguirre H, Paulina; Silva R, Samy; Hitschfeld G, Mario

    2006-01-01

    The Laboratory of Radio-sterilized Biological Tissues Processing (LPTR) belonging to the Chilean Commission of Nuclear Energy and the International Atomic Energy Agency have played a paramount role in our country, concerning the biological tissue processing, which can be radio-sterilized as human skin, pig skin, amniotic membrane, human bone and bovine bone. The frozen radio.-sterilized human skin processing began in 2001, by means of putting into practice the knowledge acquired in training courses through the IAEA and the experience transferred by experts who visited our laboratory. The human skin processing of dead donor can be divided into 6 stages: a) Profuse washing with physiological sterilized serum in to remove the microorganisms, chemical and pharmacological compounds; b) immersion in glycerol solution at 10% to better keep the stored tissues; c) packing, to avoid post manipulation of the sterilized tissue; d) microbiological controls which allow and guarantee a sterility assurance level of 10 6 ; e) radio-sterilization, technique that consists of exposing the grafts to electromagnetic gamma waves which eliminate the microorganisms of the tissue, f) and finally, dispatching and liberation of the frozen sterilized human skin for its clinical use in different centers that take care of burned people. The LPTR receives feedback from surgeons who have used these tissues in order to improve the processing stages based in an integral quality system ISO 9001.2000. The State Health System in our country counts on limited and scarce resources to implement synthetic substitutes that is why It is considered necessary to spread the use of these noble tissues which have sterility assurance and they are processed at low price

  13. Ocular lens availability of glutathione from collagen inserts for protection of eye from radiation

    International Nuclear Information System (INIS)

    Omer, S.A.

    2003-01-01

    Full text: Ocular inserts of glutathione ( G ) were prepared using 1 % collagen solution containing free G ,liposomal G and liposomal G with Concanavalin A ,a specific targeting agent of G to ocular lens. These inserts have to be sterilized for in-vivo ophthalmic application by exposure to U V radiation for 2 hr. using dry ice and acetone for protection of G from thermal degradation. In vitro release characteristics of G (17.0 μ mole) from the prepared inserts were investigated at 37deg C in phosphate buffer pH 7.4 . The results of release data showed that the release of G from inserts were arranged in the following order, free G, liposomal G with or without Concanavalin A. The extent of uptake of G from the collagen inserts by rabbit cornea was also tested. The results of ocular lens availability of G from collagen inserts revealed that a highly significant increase in the uptake of G by ocular lenses,where the percentages drug uptake from the applied doses at T max were 1.12% (p(0.05), 2.12% (p(0.01) and 3.4% (p(0.001) in case of using collagen inserts containing free G, liposomal G and liposomal G with Concanavalin A respectively. That is to say,lipid nature of liposomes together with Concanavlin A improved the penetration of the entrapped hydrophilic G through corneal barrier to the ocular lenses

  14. Acoustic lens for capacitive micromachined ultrasonic transducers

    Science.gov (United States)

    Chang, Chienliu; Firouzi, Kamyar; Park, Kwan Kyu; Sarioglu, Ali Fatih; Nikoozadeh, Amin; Yoon, Hyo-Seon; Vaithilingam, Srikant; Carver, Thomas; Khuri-Yakub, Butrus T.

    2014-08-01

    Capacitive micromachined ultrasonic transducers (CMUTs) have great potential to compete with traditional piezoelectric transducers in therapeutic ultrasound applications. In this paper we have designed, fabricated and developed an acoustic lens formed on the CMUT to mechanically focus ultrasound. The acoustic lens was designed based on the paraxial theory and made of silicone rubber for acoustic impedance matching and encapsulation. The CMUT was fabricated based on the local oxidation of silicon (LOCOS) and fusion-bonding. The fabricated CMUT was verified to behave like an electromechanical resonator in air and exhibited wideband response with a center frequency of 2.2 MHz in immersion. The fabrication for the acoustic lens contained two consecutive mold castings and directly formed on the surface of the CMUT. Applied with ac burst input voltages at the center frequency, the CMUT with the acoustic lens generated an output pressure of 1.89 MPa (peak-to-peak) at the focal point with an effective focal gain of 3.43 in immersion. Compared to the same CMUT without a lens, the CMUT with the acoustic lens demonstrated the ability to successfully focus ultrasound and provided a viable solution to the miniaturization of the multi-modality forward-looking endoscopes without electrical focusing.

  15. Acoustic lens for capacitive micromachined ultrasonic transducers

    International Nuclear Information System (INIS)

    Chang, Chienliu; Firouzi, Kamyar; Sarioglu, Ali Fatih; Nikoozadeh, Amin; Yoon, Hyo-Seon; Vaithilingam, Srikant; Carver, Thomas; Khuri-Yakub, Butrus T; Kyu Park, Kwan

    2014-01-01

    Capacitive micromachined ultrasonic transducers (CMUTs) have great potential to compete with traditional piezoelectric transducers in therapeutic ultrasound applications. In this paper we have designed, fabricated and developed an acoustic lens formed on the CMUT to mechanically focus ultrasound. The acoustic lens was designed based on the paraxial theory and made of silicone rubber for acoustic impedance matching and encapsulation. The CMUT was fabricated based on the local oxidation of silicon (LOCOS) and fusion-bonding. The fabricated CMUT was verified to behave like an electromechanical resonator in air and exhibited wideband response with a center frequency of 2.2 MHz in immersion. The fabrication for the acoustic lens contained two consecutive mold castings and directly formed on the surface of the CMUT. Applied with ac burst input voltages at the center frequency, the CMUT with the acoustic lens generated an output pressure of 1.89 MPa (peak-to-peak) at the focal point with an effective focal gain of 3.43 in immersion. Compared to the same CMUT without a lens, the CMUT with the acoustic lens demonstrated the ability to successfully focus ultrasound and provided a viable solution to the miniaturization of the multi-modality forward-looking endoscopes without electrical focusing. (paper)

  16. A dose-finding, long-term study on the use of calcium chloride in saline solution as a method of nonsurgical sterilization in dogs: evaluation of the most effective concentration with the lowest risk

    OpenAIRE

    Leoci, Raffaella; Aiudi, Giulio; Silvestre, Fabio; Lissner, Elaine A; Marino, Fabio; Lacalandra, Giovanni M

    2014-01-01

    Background Canine overpopulation is a global issue with serious health and welfare implications. Nonsurgical methods of sterilization could yield positive impacts on this problem, but no long-term data on such methods are available. The objective of the current investigation was to determine the effects of intratesticular injections of calcium chloride dihydrate (CaCl2) in saline in dogs over a one year period. Five concentrations (0%, 10%, 20%, 30%, 60%) of CaCl2 in saline were administered ...

  17. [Sterilization: necessity or genocide?].

    Science.gov (United States)

    Muraro, R M

    1991-01-01

    Recent warnings by the UN Fund for Population Activities about the rapid growth of the world population and the overwhelming role in it played by impoverished women in developing countries are of interest to all women in Latin America. According to the document, Third World Women require drastic improvements in their socioeconomic positions in order to achieve reductions in their family sizes and avoid an increase in the world population from 5 billion at present to 10 billion in 2025, which would be a disaster for the planet. The document states that much of the environmental damage that would occur would be attributable to the combination of poverty and rapid population increase. If the proportion of the world's women using contraceptives increases from the current 45% to 58% by the year 2000, the world population in 2025 will be 8.5 billion. The document recommends that the amount of money invested in family planning be greatly increased by 2000 in order to make possible increased use of family planning. It appears, however, that much of the funding for family planning is under the control of private organizations and is used to serve the interests of foreign countries. The 2 principal private family planning organizations in Brazil, for example, received 18.2 million US dollars between 1978--84, which were used largely to finance a campaign of mass sterilization. Brazil's rate of population growth, which was 2.1% in 1980-85 and 1.8% in 1990, is expected to drop to 1.6% in 1995. With the decline in the rate of growth, the population will be 170 million in 2000 instead of the 220 million projected using data from the 1970s. A much higher proportion of fertile-aged women in Brazil is sterilized than in the US or Europe . Closer examination of the premises behind family planning policies shows them to be questionable. The premise that population density affects the environment is questionable; Japan, West Germany, and Holland have some of the highest population

  18. Radial focusing of a relativistic electron beam in a bipotential electrostatic lens

    International Nuclear Information System (INIS)

    Genoni, T.C.

    1994-01-01

    The focusing of a relativistic electron beam in a bipotential electrostatic lens is discussed. An iterative scheme for the solution of the paraxial ray equation is used to derive approximate analytic formulas for the lens parameters and lens transfer matrix elements. The formulas are compared to results of direct numerical integration of the paraxial ray equation

  19. Food irradiation and sterilization

    International Nuclear Information System (INIS)

    Josephson, E.S.

    1981-01-01

    Radiation sterilization of food (radappertization) requires exposing food in sealed containers to ionizing radiation at absorbed doses high enough (25 to 70 kGy) to kill all organisms of food spoilage and public health significance. Radappertization is analogous to thermal canning in achieving shelf stability (long term storage without refrigeration). Except for dry products in which autolysis is negligible, the radappertization process also requires that the food be heated to an internal temperature of 70 to 80 0 C (bacon to 53 0 C) to inactivate autolytic enzymes which catalyze spoilage during storage without refrigeration. To minimize the occurrence of irradiation induced off-flavors and odors, undesirable color changes, and textural and nutritional losses from exposure to the high doses required for radappertization, the foods are vacuum sealed and irradiated frozen (-40 0 C to -20 0 C). Radappertized foods have the characteristic of fresh foods prepared for eating. Radappertization can substitute in whole or in part for some chemical food additives such as ethylene oxide and nitrites which are either toxic, carcinogenic, mutagenic, or teratogenic. After 27 years of testing for 'wholesomeness' (safety for consumption) of radappertized foods, no confirmed evidence has been obtained of any adverse effects of radappertization on the 'wholesomeness' characteristics of these foods. (author)

  20. Food irradiation and sterilization

    Science.gov (United States)

    Josephson, Edward S.

    Radiation sterilization of food (radappertization) requires exposing food in sealed containers to ionizing radiation at absorbed doses high enough (25-70 kGy) to kill all organisms of food spoilage and public health significance. Radappertization is analogous to thermal canning is achieving shelf stability (long term storage without refrigeration). Except for dry products in which autolysis is negligible, the radappertization process also requires that the food be heated to an internal temperature of 70-80°C (bacon to 53°C) to inactivate autolytic enzymes which catalyze spoilage during storage without refrigeration. To minimize the occurence of irradiation induced off-flavors and odors, undesirable color changes, and textural and nutritional losses from exposure to the high doses required for radappertization, the foods are vacuum sealed and irradiated frozen (-40°C to -20°C). Radappertozed foods have the characteristic of fresh foods prepared for eating. Radappertization can substitute in whole or in part for some chemical food additives such as ethylene oxide and nitrites which are either toxic, carcinogenic, mutagenic, or teratogenic. After 27 years of testing for "wholesomeness" (safety for consumption) of radappertized foods, no confirmed evidence has been obtained of any adverse effecys of radappertization on the "wholesomeness" characteristics of these foods.

  1. Documentation requirements for radiation sterilization

    DEFF Research Database (Denmark)

    Miller, A.

    1995-01-01

    Several standards are recently approved or are under development by the standard organizations ISO and CEN in the field of radiation sterilization. Particularly in Europe these standards define new requirements on some issues and on other issues they emphasize the necessary documentation for appr......Several standards are recently approved or are under development by the standard organizations ISO and CEN in the field of radiation sterilization. Particularly in Europe these standards define new requirements on some issues and on other issues they emphasize the necessary documentation...... for approval of radiation sterilized products. The impact of these standards on the radiation sterilization is discussed, with special attention given to a few special issues, mainly traceability and uncertainty of measurement results....

  2. Sterile pyuria: a forgotten entity

    OpenAIRE

    Goonewardene, Sanchia; Persad, Raj

    2015-01-01

    Sterile pyuria is a common entity. Yet there are no guidelines to address this issue. We have conducted a systematic review over 20 years and reviewed the results. Guidelines for assessment, diagnosis and management are developed based on these results.

  3. Sterile pyuria: a forgotten entity.

    Science.gov (United States)

    Goonewardene, Sanchia; Persad, Raj

    2015-10-01

    Sterile pyuria is a common entity. Yet there are no guidelines to address this issue. We have conducted a systematic review over 20 years and reviewed the results. Guidelines for assessment, diagnosis and management are developed based on these results.

  4. Sterility assurance of medical products

    International Nuclear Information System (INIS)

    Dierksheide, W.C.

    1977-01-01

    The present methods of regulating medical devices under the Food, Drug and Cosmetic Act in the United States of America are outlined. Reference is made to the position of drugs sterilized by irradiation. Surgical sutures and surgical dressings are regulated as drugs. Some details are given of proposed changes in the Act. The subject is further discussed under the headings: sterility assurance, and biocompatibility. (U.K.)

  5. Food packaging and radiation sterilization

    International Nuclear Information System (INIS)

    Kawamura, Yoko

    1998-01-01

    Radiation sterilization has several merits that it is a positively effective sterilization method, it can be used to sterilize low heat-resistant containers and high gas barrier films, and there is no possibility of residual chemicals being left in the packages. It has been commercially used in 'Bag in a Box' and some food containers. The γ ray and an electron beam are commonly used in radiation sterilization. The γ ray can sterilize large size containers and containers with complex shapes or sealed containers due to its strong transmission capability. However, since the equipment tends to be large and expensive, it is generally used in off production lines. On the other hand, it is possible to install and electron beam system on food production lines since the food can be processed in a short time due to its high beam coefficient and its ease of maintenance, even though an electron beam has limited usage such as sterilizing relatively thin materials and surface sterilization due to the weak transmission. A typical sterilization dose is approximately 10-30 kGy. Direct effects impacting packaging materials, particularly plastics, include scission of polymer links, cross-linkage between polymers, and generating radiolysis products such as hydrogen, methane, aliphatic hydrocarbons, etc. Furthermore, under the existence of oxygen, the oxygen radicals generated by the radiation will oxidize and peroxidize polymer chains and will generate alcohol and carbonyl groups, which shear polymer links, and generate oxygen containing low molecular compounds. As a result, degradation of physical strength such as elongation and seal strength, generating foreign odor, and an increase in global migration values shown in an elution test are sometimes evident. The food packages have different shapes, materials, additives, number of microorganisms and purpose. Therefor the effects of radiation, the optimum dose and so on must be investigated on the individual package. (J.P.N.)

  6. 21 CFR 522.914 - Fenprostalene solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Fenprostalene solution. 522.914 Section 522.914... Fenprostalene solution. (a) Specifications—(1) Cattle. Each milliliter of sterile solution contains 0.5 milligram of fenprostalene. (2) Swine. Each milliliter of sterile solution contains 0.25 milligram of...

  7. Radiation sterilization of skin allograft

    Science.gov (United States)

    Kairiyama, E.; Horak, C.; Spinosa, M.; Pachado, J.; Schwint, O.

    2009-07-01

    In the treatment of burns or accidental loss of skin, cadaveric skin allografts provide an alternative to temporarily cover a wounded area. The skin bank facility is indispensable for burn care. The first human skin bank was established in Argentina in 1989; later, 3 more banks were established. A careful donor selection is carried out according to the national regulation in order to prevent transmissible diseases. As cadaveric human skin is naturally highly contaminated, a final sterilization is necessary to reach a sterility assurance level (SAL) of 10 -6. The sterilization dose for 106 batches of processed human skin was determined on the basis of the Code of Practice for the Radiation Sterilization of Tissue Allografts: Requirements for Validation and Routine Control (2004) and ISO 11137-2 (2006). They ranged from 17.6 to 33.4 kGy for bioburdens of >10-162.700 CFU/100 cm 2. The presence of Gram negative bacteria was checked for each produced batch. From the analysis of the experimental results, it was observed that the bioburden range was very wide and consequently the estimated sterilization doses too. If this is the case, the determination of a tissue-specific dose per production batch is necessary to achieve a specified requirement of SAL. Otherwise if the dose of 25 kGy is preselected, a standardized method for substantiation of this dose should be done to confirm the radiation sterilization process.

  8. Radiation sterilization of skin allograft

    International Nuclear Information System (INIS)

    Kairiyama, E.; Horak, C.; Spinosa, M.; Pachado, J.; Schwint, O.

    2009-01-01

    In the treatment of burns or accidental loss of skin, cadaveric skin allografts provide an alternative to temporarily cover a wounded area. The skin bank facility is indispensable for burn care. The first human skin bank was established in Argentina in 1989; later, 3 more banks were established. A careful donor selection is carried out according to the national regulation in order to prevent transmissible diseases. As cadaveric human skin is naturally highly contaminated, a final sterilization is necessary to reach a sterility assurance level (SAL) of 10 -6 . The sterilization dose for 106 batches of processed human skin was determined on the basis of the Code of Practice for the Radiation Sterilization of Tissue Allografts: Requirements for Validation and Routine Control (2004) and ISO 11137-2 (2006). They ranged from 17.6 to 33.4 kGy for bioburdens of >10-162.700 CFU/100 cm 2 . The presence of Gram negative bacteria was checked for each produced batch. From the analysis of the experimental results, it was observed that the bioburden range was very wide and consequently the estimated sterilization doses too. If this is the case, the determination of a tissue-specific dose per production batch is necessary to achieve a specified requirement of SAL. Otherwise if the dose of 25 kGy is preselected, a standardized method for substantiation of this dose should be done to confirm the radiation sterilization process.

  9. Radiation sterilization of buckwheat flour

    International Nuclear Information System (INIS)

    Ito, Hitoshi; Ishigaki, Isao; Muramatsu, Nobuyuki; Oohinata, Hiroshi; Ohara, Tadahiko; Oh-ike, Terui; Matsuhashi, Tetsujiro.

    1989-01-01

    For buckwheat noodle in which taste is important and its main material, buckwheat flour, the ordinary sterilization by heating or ozone cannot be applied. The number of the bacteria sticking to buckwheat flour is much more as compared with that of wheat flour, and is 10 5 -10 7 per 1 g. The effective countermeasures are not yet found. Also noxious insects are apt to infect buckwheat flour. It has been known that radiation is effective for the sterilization of flavorings. In this study, the microorganism contamination of buckwheat flour and sterilization dose, the change of taste and properties after irradiation, and the capability of storage were examined, and the results are reported. The bacteria in buckwheat flour were mostly Erwinia which forms yellow colonies, and is plant-parasitic bacteria having sugar fermentation function, and also some Enterobacer, Klebsiella and Aspergillus were found. When gamma ray was irradiated on buckwheat flour, it was sterilized to less than 10 3 per 1 g bacteria at the dose of 5 kGy, and microorganisms were almost sterilized at 10 kGy. With the electron beam of 3 MeV, the effect of sterilization somewhat decreased. The noodle-making property of irradiated buckwheat flour, and the taste and storage capability of the noodle of irradiated flour were tested. (K.I.)

  10. Microbial contamination of soft contact lenses & accessories in asymptomatic contact lens users.

    Science.gov (United States)

    Thakur, Deeksha V; Gaikwad, Ujjwala N

    2014-08-01

    With increasing use of soft contact lenses the incidence of contact lens induced infections is also increasing. This study was aimed to assess the knowledge of new and existing contact lens users about the risk of microbial contamination associated with improper use and maintenance of contact lenses, type of microbial flora involved and their potential to cause ophthalmic infections. Four samples each from 50 participants (n=200) were collected from the lenses, lens care solutions, lens care solution bottles and lens cases along with a questionnaire regarding their lens use. The samples were inoculated onto sheep blood agar, Mac Conkey's agar and Sabouraud's dextrose agar. Organisms were identified using standard laboratory protocols. Overall rate of microbial contamination among the total samples was 52 per cent. The most and the least contaminated samples were found to be lens cases (62%) and lens care solution (42%), respectively. The most frequently isolated contaminant was Staphylococcus aureus (21%) followed by Pseudomonas species (19.5%). Majority (64%) of the participants showed medium grade of compliance to lens cleaning practices. Rate of contamination was 100 and 93.75 per cent respectively in those participants who showed low and medium compliance to lens care practices as compared to those who had high level of compliance (43.75%) (PLens care practices amongst the participants were not optimum which resulted into high level contamination. Hence, creating awareness among the users about the lens care practices and regular cleaning and replacements of lens cases are required.

  11. How Could Contact Lens Wearers Be at Risk of Acanthamoeba Infection? A Review

    Directory of Open Access Journals (Sweden)

    Youhanna W. Ibrahim

    2009-01-01

    Full Text Available Contact lens wear is highly influential on the incidence of ulcerative keratitis worldwide, particularly in developed countries. The association between Acanthamoeba keratitis and contact lens wear is firmly established; it may account for up to 95% of the reported cases. Before the popularisation of soft contact lens wear, Acanthamoeba keratitis was extremely rare. In 2000 it was estimated that the number of contact lens wearers worldwide was about 80 million, out of whom 33 million were in the United States and 90% of them wore hydrogel soft lenses. Contact lens-related problems depend on many factors, such as lens material, wearing modality, lens hygiene, type of lens-caring solution, the degree of compliance of the lens user with lens wear and care procedures, lens overwear, sleeping in lenses, rate of changing lenses, and lens case hygiene. This paper is a thorough review of the literature aiming to highlight the role of one of the main risk factors of infectious keratitis, contact lens wear, and also to show the responsibility of lens users in aggravating this risk.

  12. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... new application of artificial intelligence shows whether a patient’s eyes point to high blood pressure or risk ...

  13. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... ask for a prescription. There is no such thing as a "one size fits all" contact lens. ...

  14. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... had not been properly fitted by an eye care professional, the lenses stuck to my eye like ... lenses do not require the same level of care or consideration as a standard contact lens because ...

  15. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her ...

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... Costume Contact Lenses Can Ruin Vision Eye Makeup Safety In fact, it is illegal to sell colored ...

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... with Colored Contact Lenses Julian: Teenager Blinded In One Eye By Non-Prescription Contact Lens Laura: Vision ... Robyn: Blurry Vision and Daily Eye Drops After One Use Facts About Colored Contacts and Halloween Safety ...

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For ...

  19. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... in a pair of colored contact lenses, Laura Butler of Parkersburg, W.Va., had "extreme pain in ... to wear any kind of contact lens. In Butler's case, the lenses caused an infection and left ...

  20. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses ...

  1. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... an impulsive buy from a souvenir shop, but 10 hours after she first put in a pair ... Prescription Contact Lens Laura: Vision Loss After Just 10 Hours Robyn: Blurry Vision and Daily Eye Drops ...

  2. bubble chamber lens

    CERN Multimedia

    Before the days of electronic detectors, visual techniques were used to detect particles, using detectors such as spark chambers and bubble chambers. This plexiglass lens was used to focus the image of tracks so they could be photographed.

  3. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Contact Lens Facts Over-the-Counter Costume Contacts May Contain Chemicals Harmful to Eyes Four Ways Over- ... without a prescription are breaking the law, and may be fined $11,000 per violation. "Many of ...

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ...

  5. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... an ophthalmologist — an eye medical doctor — who will measure each eye and talk to you about proper ...

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. Follow the contact lens care directions for cleaning, disinfecting, and wearing the lenses. Never share contact ... with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  7. Geometry-invariant gradient refractive index lens: analytical ray tracing.

    Science.gov (United States)

    Bahrami, Mehdi; Goncharov, Alexander V

    2012-05-01

    A new class of gradient refractive index (GRIN) lens is introduced and analyzed. The interior iso-indicial contours mimic the external shape of the lens, which leads to an invariant geometry of the GRIN structure. The lens model employs a conventional surface representation using a coincoid of revolution with a higher-order aspheric term. This model has a unique feature, namely, it allows analytical paraxial ray tracing. The height and the angle of an arbitrary incident ray can be found inside the lens in a closed-form expression, which is used to calculate the main optical characteristics of the lens, including the optical power and third-order monochromatic aberration coefficients. Moreover, due to strong coupling of the external surface shape to the GRIN structure, the proposed GRIN lens is well suited for studying accommodation mechanism in the eye. To show the power of the model, several examples are given emphasizing the usefulness of the analytical solution. The presented geometry-invariant GRIN lens can be used for modeling and reconstructing the crystalline lens of the human eye and other types of eyes featuring a GRIN lens.

  8. Spacecraft Sterilization Using Non-Equilibrium Atmospheric Pressure Plasma

    Science.gov (United States)

    Cooper, Moogega; Vaze, Nachiket; Anderson, Shawn; Fridman, Gregory; Vasilets, Victor N.; Gutsol, Alexander; Tsapin, Alexander; Fridman, Alexander

    2007-01-01

    As a solution to chemically and thermally destructive sterilization methods currently used for spacecraft, non-equilibrium atmospheric pressure plasmas are used to treat surfaces inoculated with Bacillus subtilis and Deinococcus radiodurans. Evidence of significant morphological changes and reduction in viability due to plasma exposure will be presented, including a 4-log reduction of B. subtilis after 2 minutes of dielectric barrier discharge treatment.

  9. Genomic networks of hybrid sterility.

    Directory of Open Access Journals (Sweden)

    Leslie M Turner

    2014-02-01

    Full Text Available Hybrid dysfunction, a common feature of reproductive barriers between species, is often caused by negative epistasis between loci ("Dobzhansky-Muller incompatibilities". The nature and complexity of hybrid incompatibilities remain poorly understood because identifying interacting loci that affect complex phenotypes is difficult. With subspecies in the early stages of speciation, an array of genetic tools, and detailed knowledge of reproductive biology, house mice (Mus musculus provide a model system for dissecting hybrid incompatibilities. Male hybrids between M. musculus subspecies often show reduced fertility. Previous studies identified loci and several X chromosome-autosome interactions that contribute to sterility. To characterize the genetic basis of hybrid sterility in detail, we used a systems genetics approach, integrating mapping of gene expression traits with sterility phenotypes and QTL. We measured genome-wide testis expression in 305 male F2s from a cross between wild-derived inbred strains of M. musculus musculus and M. m. domesticus. We identified several thousand cis- and trans-acting QTL contributing to expression variation (eQTL. Many trans eQTL cluster into eleven 'hotspots,' seven of which co-localize with QTL for sterility phenotypes identified in the cross. The number and clustering of trans eQTL-but not cis eQTL-were substantially lower when mapping was restricted to a 'fertile' subset of mice, providing evidence that trans eQTL hotspots are related to sterility. Functional annotation of transcripts with eQTL provides insights into the biological processes disrupted by sterility loci and guides prioritization of candidate genes. Using a conditional mapping approach, we identified eQTL dependent on interactions between loci, revealing a complex system of epistasis. Our results illuminate established patterns, including the role of the X chromosome in hybrid sterility. The integrated mapping approach we employed is

  10. SOLUTIONING

    Directory of Open Access Journals (Sweden)

    Maria de Hoyos Guajardo, Ph.D. Candidate, M.Sc., B.Eng.

    2004-11-01

    Full Text Available The theory that is presented below aims to conceptualise how a group of undergraduate students tackle non-routine mathematical problems during a problem-solving course. The aim of the course is to allow students to experience mathematics as a creative process and to reflect on their own experience. During the course, students are required to produce a written ‘rubric’ of their work, i.e., to document their thoughts as they occur as well as their emotionsduring the process. These ‘rubrics’ were used as the main source of data.Students’ problem-solving processes can be explained as a three-stage process that has been called ‘solutioning’. This process is presented in the six sections below. The first three refer to a common area of concern that can be called‘generating knowledge’. In this way, generating knowledge also includes issues related to ‘key ideas’ and ‘gaining understanding’. The third and the fourth sections refer to ‘generating’ and ‘validating a solution’, respectively. Finally, once solutions are generated and validated, students usually try to improve them further before presenting them as final results. Thus, the last section deals with‘improving a solution’. Although not all students go through all of the stages, it may be said that ‘solutioning’ considers students’ main concerns as they tackle non-routine mathematical problems.

  11. Sterilization in Finland: from eugenics to contraception.

    Science.gov (United States)

    Hemminki, E; Rasimus, A; Forssas, E

    1997-12-01

    The purpose of this paper was to describe the transition of sterilization in Finland from an eugenic tool to a contraceptive. Historical data were drawn from earlier reports in Finnish. Numbers of and reasons for sterilizations since 1950 were collected from nationwide sterilization statistics. Prevalence, characteristics of sterilized women, and women's satisfaction with sterilizations were studied from a 1994 nationwide survey (74% response rate). Logistic regression was used for adjustments. In the first half of the 20th century, eugenic ideology had influence in Finland as in other parts of Europe, and the 1935 and 1950 sterilization laws had an eugenic spirit. Regardless of this, the numbers of eugenic sterilizations remained low, and in practice, family planning was the main reason for sterilization. Nonetheless, prior to 1970 not all sterilizations were freely chosen, because sterilizations were sometimes used as a precondition for abortion. Female sterilizations showed remarkable fluctuation over time. Male sterilizations have been rare. The reasons stipulated by the law did not explain the numbers of sterilizations. In a 1994 survey, 9% of Finnish women reported they were using sterilization as their current contraceptive method (n = 189). Compared to women using other contraceptive methods, sterilized women were older, had had more births and pregnancies, and came from lower social classes. Sterilized women were satisfied with their sterilization, but there were women (8.5%) who regretted it. In conclusion, sterilizations have been and are likely to continue to be an important family planning method in Finland. The extreme gender ratio suggests a need for promoting male sterilizations, and women's expressed regrets suggest consideration of a higher age limit.

  12. Non-compliance in contact lens wear.

    Science.gov (United States)

    Claydon, B E; Efron, N

    1994-10-01

    Non-compliance is emerging as a critical issue in the contact lens field. This problem has been studied at depth in general health care situations and is seen as the responsibility of both practitioner and patient (client) working in a health care partnership. The contact lens practitioner and patient present a specific case for the study of non-compliance in areas such as hygiene, solution use, appointment attendance and wearing times. From 40 to 91% of contact lens patients have been reported as non-complaint in the use of recommended care and maintenance regimens and many of these are confused or ignorant about their behaviour. In order to arrive at a general set of conclusions from the studies published to date, it is important to understand the methodology of each study, it purpose, the definition of non-compliance used and the way the results were analysed and described. This review summarizes the research into non-compliance in the contact lens field to data. A set of general conclusions is drawn and a model for compliance in the context of contact lens practice is proposed.

  13. Radiation: A means of sterilization

    International Nuclear Information System (INIS)

    Mukherjee, R.N.

    1975-01-01

    The sterilization of medical products by ionizing radiation is a well-established industrial process in a number of technologically advanced countries. It is indeed encouraging to note the rate of growth experienced during the past fifteen years. Starting with the first commercial plant in the early sixties in the USA there are to date more than sixty large facilities of this kind located in USA, Canada, Australia and the countries of Europe including USSR. The geographical distribution of these sterilization plants is rather unbalanced. In this respect Europe is far ahead of the other continents of the world, with about 65% of all sterilization plants, followed by North and South America with 17%, Asia with 8%, Australia and New Zealand with 9% and Africa with only 1%. During the last 10 years the IAEA has actively contributed to the development of radiation sterilization practices and technology in the Member States, with particular emphasis on the developing countries. Such promotional efforts have been made by (a) supporting co-ordinated research to accumulate relevant technical information, (b) organizing scientific meetings and training courses, (c) providing technical expertise in the form of fellowships and expert services, (d) providing technical assistance to conduct market surveys and economic feasibility assessment, (e) scientific publications, including technical manuals and proceedings reports, and (f) assistance in the formulation of an international 'Code of Practice' for standardization of the manufacturing practices for radiation sterilized medical products to meet the specified requirements of the various national Pharmacopoeias and of the international consumer market

  14. Sterilization of mentally retarded persons.

    Science.gov (United States)

    Van der Merwe, J V; Roux, J P

    1987-08-01

    South Africa's Abortion and Sterilization Act No 2 (1975) authorizes sterilization for severely retarded women provided the procedure is performed in a state hospital, certified by 2 medical practitioners (1 a psychiatrist), and the parent or guardian gives informed consent. Since 1975, 152 sterilizations (140 female, 12 male) have been performed under the provisions of this Act at Pretoria's H F Verwoerd Hospital. 92% of the patients were under 20 years of age. The majority were classified as profoundly or severely retarded (74) or moderately severely retarded (68). There were 20 patients with Down's syndrome and 22 with cerebral palsy. Hysterectomy was the method of choice in the 109 women in whom menstrual hygiene was a pertinent factor; the remaining 31 women were sterilized by tubal ligation. 98% of the parents or guardians of hysterectomy acceptors surveyed were satisfied with their decision and its outcome. Several indicated their daughter was more calm, cooperative, productive, and less irritable once relieved of her menstrual periods. A multidisciplinary team approach to the decision making process and the individualization of each case are essential to protect the rights of the mentally retarded. Factors such as the psychological trauma likely to result from pregnancy and childbirth, an inability to use contraception, and unsuitability to rear a child must be demonstrated. To ensure that legislation pertaining to the sterilization of the mentally retarded does not lead to abuse, inputs from the mental health professions are required.

  15. A dose-finding, long-term study on the use of calcium chloride in saline solution as a method of nonsurgical sterilization in dogs: evaluation of the most effective concentration with the lowest risk.

    Science.gov (United States)

    Leoci, Raffaella; Aiudi, Giulio; Silvestre, Fabio; Lissner, Elaine A; Marino, Fabio; Lacalandra, Giovanni M

    2014-10-14

    Canine overpopulation is a global issue with serious health and welfare implications. Nonsurgical methods of sterilization could yield positive impacts on this problem, but no long-term data on such methods are available. The objective of the current investigation was to determine the effects of intratesticular injections of calcium chloride dihydrate (CaCl2) in saline in dogs over a one year period. Five concentrations (0%, 10%, 20%, 30%, 60%) of CaCl2 in saline were administered via intratesticular injection to groups of 10 dogs each. Total sperm count and motility, blood levels of testosterone, and side effects were examined at 0, 2, 6, and 12 months post-injection (PI). Testicular size and semen volume were examined at 0 and 12 months PI. Total sperm count, semen volume and testosterone showed significant dose-dependent decreases upon treatment with 10%-60% CaCl2 compared with either the control group (0% CaCl2) or baseline for each treatment group. Azoospermia was achieved for at least 12 months PI in 60% and 80% of treated dogs after administration of a 10% and 20% CaCl2, respectively. Treatment with 30% or 60% CaCl2 resulted in azoospermia in 100% of dogs, but more side effects were observed, while no side effects were noticed at lower doses. For each treatment group, testosterone levels had decreased an average of 35%-70% at 6 months following treatment. However, testosterone levels rebounded by the 12-month time point in all groups except the highest dosage group (60% CaCl2), which remained at the low end of physiological range throughout the study. Sperm motility dropped to zero or near zero in all dogs treated with CaCl2. Testicular size was significantly smaller at 12 months PI for all groups when compared to baseline. This first long-term study confirms reports of the efficacy of CaCl2 sterilization. However, at dosages free of adverse events, calcium chloride in saline may not provide permanent sterilization as previously believed. Future work should

  16. Neutrinos in a Sterile Throat

    CERN Document Server

    Gripaios, Ben Matthew

    2007-01-01

    We consider field-theoretic models of a warped extra dimension with multiple throats, in which fermions that are singlets of the Standard Model gauge group propagate in a separate throat from the Standard Model fields, which we call the sterile throat. The singlets mix with Standard Model fields via interactions localized on the UV brane that connects the two throats. This leads to three, light, mostly-active, Majorana neutrinos via a higher-dimensional see-saw mechanism, together with Kaluza-Klein towers of mostly-sterile neutrinos, whose scale is set by the warp factor in the sterile throat and can be very low if the throat is deep. We suggest that a model of this kind may explain all the neutrino data, reconciling the LSND result with astrophysical constraints.

  17. Scleral lens for keratoconus: technology update

    Science.gov (United States)

    Rathi, Varsha M; Mandathara, Preeji S; Taneja, Mukesh; Dumpati, Srikanth; Sangwan, Virender S

    2015-01-01

    Scleral lenses are large diameter lenses which rest over the sclera, unlike the conventional contact lenses which rest on the cornea. These lenses are fitted to not touch the cornea and there is a space created between the cornea and the lens. These lenses are inserted in the eyes after filling with sterile isotonic fluid. Generally, scleral contact lenses are used for high irregular astigmatism as seen in various corneal ectatic diseases such as keratoconus, pellucid marginal degeneration, or/and as liquid bandage in ocular surface disorders. In this article, we review the new developments, that have taken place over the years, in the field of scleral contact lenses as regard to new designs, materials, manufacturing technologies, and fitting strategies particularly for keratoconus. PMID:26604671

  18. Radiation sterilization of hydrocortisone acetate

    International Nuclear Information System (INIS)

    Charef, A.; Boussaha, A.

    1989-09-01

    The feasibility of using high energy ionizing radiation for the sterilization of hydrocortisone acetate was investigated. Hydrocortisone acetate in the form of powder was exposed to different dose levels of gamma radiation using a Cobalt-60 source. The irradiated samples were examined by various physico-chemical techniques in order to detect possible radiolysis products. It was of interest to know if one could insure sterility and retain biological properties of the drug by suitable choice of radiation dose. The results showed that a 10 KGy radiation dose causes no change in the physico-chemical properties of the drug and is sufficient to obtain contaminant-free product

  19. Method of sterilization

    International Nuclear Information System (INIS)

    Peel, J.L.; Waites, W.M.

    1981-01-01

    A method of sterilisation of food packaging is described which comprises treating microorganisms with an ultraviolet irradiated solution of hydrogen peroxide to render the microorganisms non-viable. The wavelength of ultraviolet radiation used is wholly or predominantly below 325 nm and the concentration of the hydrogen peroxide is no greater than 10% by weight. The method is applicable to a wide variety of microorganisms including moulds, yeasts, bacteria, viruses and protozoa and finds particular application in the destruction of spore-forming bacteria, especially those which are dairy contaminants. (U.K.)

  20. International survey of contact lens prescribing for extended wear.

    Science.gov (United States)

    Efron, Nathan; Morgan, Philip B; Woods, Craig A

    2012-02-01

    To determine the extent of extended wear (EW) contact lens prescribing worldwide and to characterize the associated demographics and fitting patterns. Up to 1000 survey forms were sent to contact lens fitters in up to 39 countries between January and March every year for five consecutive years (2006-2010). Practitioners were asked to record data relating to the first 10 contact lens fits or refits performed after receiving the survey form. Survey data collected since 1997 was also analyzed to assess EW fitting trends since that time. Details for lens modality were received for 107,094 rigid and soft lens fits of which 88,392 were for soft lens daily wear (DW) and 7470 were for soft lens EW. Overall, EW represents 7.8% of all soft lens fits, ranging from 0.6% in Malaysia to 27% Norway. Compared with DW fittings, EW fittings can be characterized as follows: older age (32.7 ± 13.6 vs. 29.4 ± 12.0 years for DW); males are over-represented; greater proportion of refits; 72% silicone hydrogel; higher proportion of presbyopia and spherical designs; and higher proportion of monthly lens replacement. Of those wearing EW lenses, 80% use multipurpose solutions, whereas 9% do not use any care system. Between 1997 and 1999, the rate of EW prescribing decreased from 5 to 1% of all soft lens fits; it increased to a peak of 12% in 2006, and settled back to 8% by 2010. EW prescribing has failed to break through the "glass ceiling" of 15% and is unlikely to become a mainstream lens wearing modality until the already low risks of ocular complications can be reduced to be equivalent to that for DW.

  1. A catoptric lens

    International Nuclear Information System (INIS)

    Rambauske, W.R.

    1973-01-01

    The invention relates to a catoptric lens for combining energies transmitted by several sources such as lasers; said lens comprising mirrors, the reflective surfaces of which have their focuses spaced from a common axis of symmetry. By means of these reflecting surfaces, which are generated by the nutation of portions of quadratic conics about the axis of symmetry, it is possible to focus the energy emmited by several lasers at the focus of the exit-mirror reflecting surface. This can be applied to thermonuclear fusion [fr

  2. Transgenic technologies to induce sterility

    Directory of Open Access Journals (Sweden)

    Wimmer Ernst A

    2009-11-01

    Full Text Available Abstract The last few years have witnessed a considerable expansion in the number of tools available to perform molecular and genetic studies on the genome of Anopheles mosquitoes, the vectors of human malaria. As a consequence, knowledge of aspects of the biology of mosquitoes, such as immunity, reproduction and behaviour, that are relevant to their ability to transmit disease is rapidly increasing, and could be translated into concrete benefits for malaria control strategies. Amongst the most important scientific advances, the development of transgenic technologies for Anopheles mosquitoes provides a crucial opportunity to improve current vector control measures or design novel ones. In particular, the use of genetic modification of the mosquito genome could provide for a more effective deployment of the sterile insect technique (SIT against vector populations in the field. Currently, SIT relies on the release of radiation sterilized males, which compete with wild males for mating with wild females. The induction of sterility in males through the genetic manipulation of the mosquito genome, already achieved in a number of other insect species, could eliminate the need for radiation and increase the efficiency of SIT-based strategies. This paper provides an overview of the mechanisms already in use for inducing sterility by transgenesis in Drosophila and other insects, and speculates on possible ways to apply similar approaches to Anopheles mosquitoes.

  3. Sterile neutrino constraints from cosmology

    DEFF Research Database (Denmark)

    Hamann, Jan; Hannestad, Steen; Raffelt, Georg G.

    2012-01-01

    The presence of light particles beyond the standard model's three neutrino species can profoundly impact the physics of decoupling and primordial nucleosynthesis. I review the observational signatures of extra light species, present constraints from recent data, and discuss the implications of po...... of possible sterile neutrinos with O(eV)-masses for cosmology....

  4. Establishment of a sterilization dose

    International Nuclear Information System (INIS)

    Kaluska, I.

    2007-01-01

    Factors that impact on product bioburden (population of diable microorganisms on or in product and/or sterile barrier system) are: Raw materials, components, product design and size, manufacturing process, manufacturing equipment, manufacturing environment and manufacturing location. Presented lecture describes all these factors in details

  5. Sterile Neutrino Search with MINOS

    Energy Technology Data Exchange (ETDEWEB)

    Devan, Alena V. [College of William and Mary, Williamsburg, VA (United States)

    2015-08-01

    MINOS, Main Injector Neutrino Oscillation Search, is a long-baseline neutrino oscillation experiment in the NuMI muon neutrino beam at the Fermi National Accelerator Laboratory in Batavia, IL. It consists of two detectors, a near detector positioned 1 km from the source of the beam and a far detector 734 km away in Minnesota. MINOS is primarily designed to observe muon neutrino disappearance resulting from three flavor oscillations. The Standard Model of Particle Physics predicts that neutrinos oscillate between three active flavors as they propagate through space. This means that a muon-type neutrino has a certain probability to later interact as a different type of neutrino. In the standard picture, the neutrino oscillation probabilities depend only on three neutrino flavors and two mass splittings, Δm2. An anomaly was observed by the LSND and MiniBooNE experiments that suggests the existence of a fourth, sterile neutrino flavor that does not interact through any of the known Standard Model interactions. Oscillations into a theoretical sterile flavor may be observed by a deficit in neutral current interactions in the MINOS detectors. A distortion in the charged current energy spectrum might also be visible if oscillations into the sterile flavor are driven by a large mass-squared difference, ms2 ~ 1 eV2. The results of the 2013 sterile neutrino search are presented here.

  6. Sterilization In Protective Trade Policies

    OpenAIRE

    寺崎, 克志; Katsushi, Terasaki; 経営学部経営学科

    2007-01-01

    Under a government budget constraint export subsidies automatically sterilize distortions caused by import tariffs, i.e., without the cost of the trade policy implementation the policy mix of export subsidies and import tariffs with budget constraint makes the economy effective.

  7. Scleral lens for keratoconus: technology update

    Directory of Open Access Journals (Sweden)

    Rathi VM

    2015-10-01

    Full Text Available Varsha M Rathi,1 Preeji S Mandathara,2 Mukesh Taneja,1 Srikanth Dumpati,1 Virender S Sangwan1 1L V Prasad Eye Institute, Hyderabad, India; 2School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia Abstract: Scleral lenses are large diameter lenses which rest over the sclera, unlike the conventional contact lenses which rest on the cornea. These lenses are fitted to not touch the cornea and there is a space created between the cornea and the lens. These lenses are inserted in the eyes after filling with sterile isotonic fluid. Generally, scleral contact lenses are used for high irregular astigmatism as seen in various corneal ectatic diseases such as keratoconus, pellucid marginal degeneration, or/and as liquid bandage in ocular surface disorders. In this article, we review the new developments, that have taken place over the years, in the field of scleral contact lenses as regard to new designs, materials, manufacturing technologies, and fitting strategies particularly for keratoconus. Keywords: keratoconus, scleral lens, technology update, PROSE

  8. Radiation sterilization: an industrial process

    International Nuclear Information System (INIS)

    Ley, F.J.

    1975-01-01

    A new dimension has been added to the use of radiation in the medical field with the introduction of radiation as a sterilizing agent. Its use in diagnosis through radioactive tracers or X-rays and in therapy administered with the most sophisticated of electrical machines or radioisotope units, is familiar in the hospital world, being well established therein. In contrast, the application of radiation sterilization is in industry where the installation of large radiation sources is already commonplace in many countries. The beginnings in the early 1950's centered on the Van de Graaff machine and linear accelerators and the pioneering efforts of Ethicon Inc. here in the United States must be recognized. However, although sterilization with electron beams is still current practice in a number of plants, the use of gamma rays from cobalt-60 is preferred. The first steps in this direction were taken by the U.K.A.E.A. which, in common with similar organizations elsewhere, was attempting to exploit the tremendous potential for cobalt-60 production arising through the rapid construction of nuclear reactors. The first full-scale commercial gamma plant was commissioned in the U.K. in 1960. It reached a loading of 500,000 curies before its demolition after twelve years of operation. The process gained rapid acceptance within industry and approval by health authorities because it provided a ''cold'' sterilization method combining the property of lethal effect with penetration. Its immediate impact occurred in the introduction of disposable products making it possible, for example, to use heat-labile plastics and new packaging materials and package designs. Certainly, the technique has proved complementary to sterilization methods based on heat and to the use of chemical agents, in particular ethylene oxide gas

  9. 45 CFR 96.73 - Sterilization.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Sterilization. 96.73 Section 96.73 Public Welfare DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATION BLOCK GRANTS Social Services Block Grants § 96.73 Sterilization. If a State authorizes sterilization as a family planning service, it must comply...

  10. Reversal of sterilization by microsurgical technique.

    Science.gov (United States)

    Gaspari, A L; Ortensi, A; Parlangeli, V; Pellizzari, G; Setti, C; Lania, M

    1988-01-01

    Tubal sterilization techniques that spare the fimbriae and cause the least amount of tubal destruction offer the best chance for reversal of sterilization. Patients seeking reversal of sterilization should be carefully selected. Surgical technique and equipment are important factors in reversal procedures; microsurgical techniques are shown to be more effective than macroscopic techniques.

  11. Quadrupole magnetic lens

    International Nuclear Information System (INIS)

    Piskunov, V.A.

    1981-01-01

    The following connection of windings of electromagnet is suggested for simplification of the design of qUadrupole magnetic lens intended for use in radiotechnical and electron-optical devices. The mentioned windings are connected with each other by a bridge scheme and the variable resistors are switched in its diagonals in the lens containing four electromagnet with windings connected with two variable resistors the mobile contacts of which are connected with a direct current source. Current redistribution between left windings and right windings takes place at shift of mobile contact of variable resistor, and current redistribution between upper and low coils of electromagnets takes place at shifting mobile contact of the other variable resistor. In this case smooth and independent electron-optical misalignment of lens by two mutually perpendicular directions proceeds. Use of the given design of the lens in the oscillograph permits to use printing assembly for alignment plate and to reduce the number of connections at the expense of decreasing the number of resistors

  12. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. There is no such thing as a "one size fits all" contact lens. Lenses that are not properly fitted may scratch the eye or cause blood vessels to grow into the cornea. Even if you have perfect vision, you need to get an eye exam and a prescription ...

  13. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Ophthalmologist Patient Stories Español Eye Health / News Halloween Hazard: The Hidden Dangers of Buying Decorative Contact Lenses ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ...

  14. MISSING: BUBBLE CHAMBER LENS

    CERN Multimedia

    2001-01-01

    Would the person who borrowed the large bubble chamber lens from the Microcosm workshops on the ISR please return it. This is a much used piece from our object archives. If anybody has any information about the whereabouts of this object, please contact Emma.Sanders@cern.ch Thank you

  15. The Lens of Chemistry

    Science.gov (United States)

    Thalos, Mariam

    2013-01-01

    Chemistry possesses a distinctive theoretical lens--a distinctive set of theoretical concerns regarding the dynamics and transformations of a perplexing variety of organic and nonorganic substances--to which it must be faithful. Even if it is true that chemical facts bear a special (reductive) relationship to physical facts, nonetheless it will…

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her with a corneal ... A recent article from U.S. News and World Report explains what ophthalmologists are and how they can ...

  17. bubble chamber lens

    CERN Multimedia

    Was used in a PS experiment. Before the days of electronic detectors, visual techniques were used to detect particles, using detectors such as spark chambers and bubble chambers. This plexiglass lens was used to focus the image of tracks so they could be photographed.

  18. Thermal Lens Microscope

    Science.gov (United States)

    Uchiyama, Kenji; Hibara, Akihide; Kimura, Hiroko; Sawada, Tsuguo; Kitamori, Takehiko

    2000-09-01

    We developed a novel laser microscope based on the thermal lens effect induced by a coaxial beam comprised of excitation and probe beams. The signal generation mechanism was confirmed to be an authentic thermal lens effect from the measurement of signal and phase dependences on optical configurations between the sample and the probe beam focus, and therefore, the thermal lens effect theory could be applied. Two-point spatial resolution was determined by the spot size of the excitation beam, not by the thermal diffusion length. Sensitivity was quite high, and the detection ability, evaluated using a submicron microparticle containing dye molecules, was 0.8 zmol/μm2, hence a distribution image of trace chemical species could be obtained quantitatively. In addition, analytes are not restricted to fluorescent species, therefore, the thermal lens microscope is a promising analytical microscope. A two-dimensional image of a histamine molecule distribution, which was produced in mast cells at the femtomole level in a human nasal mucous polyp, was obtained.

  19. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... an Ophthalmologist Patient Stories Español Eye Health / News Halloween Hazard: The Hidden Dangers of Buying Decorative Contact ... After One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter ...

  20. Radiosterilization or sterilization by steam. Procedures for sterilization of spices

    International Nuclear Information System (INIS)

    Warmbold, J.

    1994-01-01

    The article compares two different methods for the sterilization of spices, namely radiosterilization and sterilization with steam. The first method applies ionizing radiation which can alter the chemical composition of the products. Tests have shown, however, that radiation doses up to 10 kGy will not induce the formation of carcinogenic agents in the foodstuffs, or of toxic substances, and thus are a wholesome method of preservation. Any modifications of taste, color or smell, or loss of vitamins, can be avoided by proper dose control and standard irradiation conditions. Sterilization by steam is a method achieving substantial suppression of the formation of germs, aerobic spores, yeasts, mould, and gramnegative germs, while preserving in most cases the essential oils. It may result in sensoric alterations, i.e affect the color, smell or taste, but in general the spices thus treated preserved their characteristic properties. The method is a good alternative to radiosterilization. The article adds some concluding information on mandatory labelling of irradiated food imported from third countries

  1. Microwave Sterilization and Depyrogenation System

    Science.gov (United States)

    Akse, James R.; Dahl, Roger W.; Wheeler, Richard R., Jr.

    2009-01-01

    A fully functional, microgravity-compatible microwave sterilization and depyrogenation system (MSDS) prototype was developed that is capable of producing medical-grade water (MGW) without expendable supplies, using NASA potable water that currently is available aboard the International Space Station (ISS) and will be available for Lunar and planetary missions in the future. The microwave- based, continuous MSDS efficiently couples microwaves to a single-phase, pressurized, flowing water stream that is rapidly heated above 150 C. Under these conditions, water is rapidly sterilized. Endotoxins, significant biological toxins that originate from the cell walls of gram-negative bacteria and which represent another defining MGW requirement, are also deactivated (i.e., depyrogenated) albeit more slowly, with such deactivation representing a more difficult challenge than sterilization. Several innovations culminated in the successful MSDS prototype design. The most significant is the antenna-directed microwave heating of a water stream flowing through a microwave sterilization chamber (MSC). Novel antenna designs were developed to increase microwave transmission efficiency. These improvements resulted in greater than 95-percent absorption of incident microwaves. In addition, incorporation of recuperative heat exchangers (RHxs) in the design reduced the microwave power required to heat a water stream flowing at 15 mL/min to 170 C to only 50 W. Further improvements in energy efficiency involved the employment of a second antenna to redirect reflected microwaves back into the MSC, eliminating the need for a water load and simplifying MSDS design. A quick connect (QC) is another innovation that can be sterilized and depyrogenated at temperature, and then cooled using a unique flow design, allowing collection of MGW at atmospheric pressure and 80 C. The final innovation was the use of in-line mixers incorporated in the flow path to disrupt laminar flow and increase contact time

  2. Effect Of Ethylene Oxide, Autoclave and Ultra Violet Sterilizations On Surface Topography Of Pet Electrospun Fibers

    Directory of Open Access Journals (Sweden)

    Sebnem DUZYER

    2016-11-01

    Full Text Available The aim of this study to investigate the effects of different sterilization methods on electrospun polyester. Ethylene oxide (EO, autoclave (AU and ultraviolet (UV sterilization methods were applied to electrospun fibers produced from polyethylene terephthalate (PET solutions with concentrations of 10, 15 and 20 wt.%. The surface characteristics of the fibers were examined by scanning electron microscope (SEM, atomic force microscope (AFM, surface pore size studies and contact angle measurements. Differential scanning calorimetry (DSC tests were carried out to characterize the thermal properties. Fourier Transform Infrared spectroscopy (FTIR tests were performed to analyze the micro structural properties. SEM studies showed that different sterilization methods made significant changes on the surfaces of the fibers depending on the PET concentration. Although the effects were decreased with the increasing polymer concentration, the fiber structure was damaged especially with the EO sterilization. The contact angle values were decreased with the UV sterilization method the most.

  3. Studies on the radiation chemistry of biomolecules in aqueous solution with specific objective of minimizing their radiolytic degradation. Coordinated programme for Asia and the Pacific Region on radiation sterilization practices significant to local medical supplies and conditions

    International Nuclear Information System (INIS)

    Narayana Rao, K.

    1979-01-01

    As part of a study of radiolytic degradation of pharmaceuticals during radiosterilization, the basic radiation chemistry of the B-group vitamins, nicotinamide, pyridoxin, riboflavin and thiamine, and the reaction of hydrogen peroxide with these same materials has been investigated. The various aspects studied were - radiolysis under controlled conditions, effects of phase, temperature, pH and nature and concentration of additives. Some of the conclusions are: 1) with oxygen saturated aqueous solutions containing glucose, the radiolytic degradation of the vitamins is reduced: 2) results a similar for N 2 O saturated aqueous solutions; 3) in glucose-containing solutions, the protective effect is considerably modified at higher temperatures; and 4) irradiation of air-saturated aqueous solutions in the frozen state leads to reduced decomposition. It is concluded that in the presence of oxygen, in frozen matrices at low temperature, it appears possible to reduce the radiolytic breakdown of vitamins to low levels

  4. Sterility of the uterine cavity

    DEFF Research Database (Denmark)

    Møller, Birger R.; Kristiansen, Frank V.; Thorsen, Poul

    1995-01-01

    In a prospective open study the sterility of the uterine cavity was evaluated in 99 women admitted for hysterectomy. The indications for hysterectomy were in most cases persistent irregular vaginal bleeding and fibromyomas of the uterus. Samples for both aerobic and anaerobic bacteria, Chlamydia ...... which may play a causative role in endometritis. The results indicate that inflammation of the uterine cavity should be evaluated by hysteroscopic examination before hysterectomy is undertaken in patients with persistent irregular vaginal bleeding. Udgivelsesdato: 1995-Mar...

  5. Signature of heavy sterile neutrinos at CEPC

    Science.gov (United States)

    Liao, Wei; Wu, Xiao-Hong

    2018-03-01

    We study the production of heavy sterile neutrino N , e+e-→N ν (ν ¯), at the Circular Electron Positron Collider (CEPC) and its l j j signal in its decay to three charged fermions. We study background events for this process which are mainly events coming from W pair production. We study the production of a single heavy sterile neutrino and the sensitivity of CEPC to the mixing of the sterile neutrino with active neutrinos. We study the production of two degenerate heavy sterile neutrinos in a low energy seesaw model by taking into account the constraints on mixings of sterile neutrinos from the neutrinoless double β decay experiment and the masses and mixings of active neutrinos. We show that CEPC under proposal has a good sensitivity to the mixing of sterile neutrinos with active neutrinos for a mass of a sterile neutrino around 100 GeV.

  6. Sterilization effect of atmospheric pressure non-thermal air plasma on dental instruments.

    Science.gov (United States)

    Sung, Su-Jin; Huh, Jung-Bo; Yun, Mi-Jung; Chang, Brian Myung W; Jeong, Chang-Mo; Jeon, Young-Chan

    2013-02-01

    Autoclaves and UV sterilizers have been commonly used to prevent cross-infections between dental patients and dental instruments or materials contaminated by saliva and blood. To develop a dental sterilizer which can sterilize most materials, such as metals, rubbers, and plastics, the sterilization effect of an atmospheric pressure non-thermal air plasma device was evaluated. After inoculating E. coli and B. subtilis the diamond burs and polyvinyl siloxane materials were sterilized by exposing them to the plasma for different lengths of time (30, 60, 90, 120, 180 and, 240 seconds). The diamond burs and polyvinyl siloxane materials were immersed in PBS solutions, cultured on agar plates and quantified by counting the colony forming units. The data were analyzed using one-way ANOVA and significance was assessed by the LSD post hoc test (α=0.05). The device was effective in killing E. coli contained in the plasma device compared with the UV sterilizer. The atmospheric pressure non-thermal air plasma device contributed greatly to the sterilization of diamond burs and polyvinyl siloxane materials inoculated with E. coli and B. subtilis. Diamond burs and polyvinyl siloxane materials inoculated with E. coli was effective after 60 and 90 seconds. The diamond burs and polyvinyl siloxane materials inoculated with B. subtilis was effective after 120 and 180 seconds. The atmospheric pressure non-thermal air plasma device was effective in killing both E. coli and B. subtilis, and was more effective in killing E. coli than the UV sterilizer.

  7. Comparative evaluation of four different sterilization methods on contaminated endodontic files

    Directory of Open Access Journals (Sweden)

    Malathi Yenni

    2017-01-01

    Full Text Available Background: The reuse of instruments in the field of endodontics leads to cross infection due to contamination with microbes as the instruments come into direct contact with saliva, blood, and infected tissues. Since microbes are considered to be the major cause of endodontic failures, sterilization of endodontic instruments is mandatory for maintaining asepsis to prevent cross-contamination from one person to other. Hence, the present study was conducted to compare the effectiveness of four different methods of sterilizing contaminated endodontic files. Materials and Methods: A total of 48 stainless steel K files were divided into four groups based on the sterilization method followed – Group A: Autoclave, Group B: Glass bead sterilization, Group C: Glutaraldehyde, and Group D: Quitanet Plus (aldehyde-free solution. In all the tested groups, half of the files were contaminated with Escherichia coli and remaining with Enterococcus faecalis. Then, presterilization colony counts were recorded, followed by sterilization through respective methods. Later, the sterilized files were rinsed with distilled water and 100 ul of the diluted concentration was transferred and cultured onto the respective agar plates to determine the total microbial reduction. Results: Autoclave showed complete effectiveness in reducing the microbial count followed by Quitanet Plus, glass bead sterilizer, and glutaraldehyde. Conclusion: Autoclave is considered to be the best sterilization technique to prevent cross infection in endodontic therapy.

  8. Sterile Neutrinos in Cold Climates

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Benjamin J.P. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2015-09-01

    Measurements of neutrino oscillations at short baselines contain an intriguing set of experimental anomalies that may be suggestive of new physics such as the existence of sterile neutrinos. This three-part thesis presents research directed towards understanding these anomalies and searching for sterile neutrino oscillations. Part I contains a theoretical discussion of neutrino coherence properties. The open-quantum-system picture of neutrino beams, which allows a rigorous prediction of coherence distances for accelerator neutrinos, is presented. Validity of the standard treatment of active and sterile neutrino oscillations at short baselines is verified, and non-standard coherence loss effects at longer baselines are predicted. Part II concerns liquid argon detector development for the MicroBooNE experiment, which will search for short-baseline oscillations in the Booster Neutrino Beam at Fermilab. Topics include characterization and installation of the MicroBooNE optical system; test-stand measurements of liquid argon optical properties with dissolved impurities; optimization of wavelength-shifting coatings for liquid argon scintillation light detection; testing and deployment of high-voltage surge arrestors to protect TPC field cages; and software development for optical and TPC simulation and reconstruction. Part III presents a search for sterile neutrinos using the IceCube neutrino telescope, which has collected a large sample of atmospheric-neutrino-induced events in the 1-10 TeV energy range. Sterile neutrinos would modify the detected neutrino flux shape via MSW-resonant oscillations. Following a careful treatment of systematic uncertainties in the sample, no evidence for MSW-resonant oscillations is observed, and exclusion limits on 3+1 model parameter space are derived. Under the mixing assumptions made, the 90% confidence level exclusion limit extends to sin224 ≤ 0.02 at m2 ~ 0.3 eV2, and the LSND and Mini

  9. [Correct contact lens hygiene].

    Science.gov (United States)

    Blümle, S; Kaercher, T; Khaireddin, R

    2013-06-01

    Although contact lenses have long been established in ophthalmology, practical aspects of handling contact lenses is becoming increasingly less important in the clinical training as specialist for ophthalmology. Simultaneously, for many reasons injuries due to wearing contact lenses are increasing. In order to correct this discrepancy, information on contact lenses and practical experience with them must be substantially increased from a medical perspective. This review article deals with the most important aspects for prevention of complications, i.e. contact lens hygiene.

  10. Microbial contamination of soft contact lenses & accessories in asymptomatic contact lens users

    Directory of Open Access Journals (Sweden)

    Deeksha V Thakur

    2014-01-01

    Full Text Available Background & objectives: With increasing use of soft contact lenses the incidence of contact lens induced infections is also increasing. This study was aimed to assess the knowledge of new and existing contact lens users about the risk of microbial contamination associated with improper use and maintenance of contact lenses, type of microbial flora involved and their potential to cause ophthalmic infections. Methods: Four samples each from 50 participants (n=200 were collected from the lenses, lens care solutions, lens care solution bottles and lens cases along with a questionnaire regarding their lens use. The samples were inoculated onto sheep blood agar, Mac Conkey′s agar and Sabouraud′s dextrose agar. Organisms were identified using standard laboratory protocols. Results: Overall rate of microbial contamination among the total samples was 52 per cent. The most and the least contaminated samples were found to be lens cases (62% and lens care solution (42%, respectively. The most frequently isolated contaminant was Staphylococcus aureus (21% followed by Pseudomonas species (19.5%. Majority (64% of the participants showed medium grade of compliance to lens cleaning practices. Rate of contamination was 100 and 93.75 per cent respectively in those participants who showed low and medium compliance to lens care practices as compared to those who had high level of compliance (43.75% ( p0 <0.05. Interpretation & conclusions: Lens care practices amongst the participants were not optimum which resulted into high level contamination. Hence, creating awareness among the users about the lens care practices and regular cleaning and replacements of lens cases are required.

  11. Sterile neutrinos with secret interactions — lasting friendship with cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Chu, Xiaoyong [International Center for Theoretical Physics,Strada Costiera 11, Trieste, 34014 (Italy); Dasgupta, Basudeb [Tata Institute of Fundamental Research,Homi Bhabha Road, Mumbai, 400005 (India); Kopp, Joachim [PRISMA Cluster of Excellence and Mainz Institute for Theoretical Physics,Johannes Gutenberg University, Staudingerweg 7, Mainz, 55128 (Germany)

    2015-10-06

    Sterile neutrinos with mass ≃1 eV and order 10% mixing with active neutrinos have been proposed as a solution to anomalies in neutrino oscillation data, but are tightly constrained by cosmological limits. It was recently shown that these constraints are avoided if sterile neutrinos couple to a new MeV-scale gauge boson A{sup ′}. However, even this scenario is restricted by structure formation constraints when A{sup ′}-mediated collisional processes lead to efficient active-to-sterile neutrino conversion after neutrinos have decoupled. In view of this, we reevaluate in this paper the viability of sterile neutrinos with such “secret” interactions. We carefully dissect their evolution in the early Universe, including the various production channels and the expected modifications to large scale structure formation. We argue that there are two regions in parameter space — one at very small A{sup ′} coupling, one at relatively large A{sup ′} coupling — where all constraints from big bang nucleosynthesis (BBN), cosmic microwave background (CMB), and large scale structure (LSS) data are satisfied. Interestingly, the large A{sup ′} coupling region is precisely the region that was previously shown to have potentially important consequences for the small scale structure of dark matter halos if the A{sup ′} boson couples also to the dark matter in the Universe.

  12. Feasibility of sterilizing traditional Chinese medicines by gamma-irradiation

    International Nuclear Information System (INIS)

    Fang Xingwang; Wu Jilan

    1998-01-01

    The feasibility of sterilizing traditional Chinese medicines (TCMs) by γ-irradiation has been systematically evaluated by the biological, toxicological and physicochemical tests on irradiated hundreds of TCMs. Those TCMs investigated in general show no significant biological or toxicological changes after irradiation, yet physicochemical changes are detectable in some irradiated TCMs, and water in TCMs enhances the effects. Those results obtained from radiolysis of some major effective components of TCMs in aqueous or ethanolic solutions reveal that the site selection of radiolytically generated radicals follows the example of simple compounds with same function groups. Wholesomeness and chemical clearance present a bright future to sterilizing TCMs by γ irradiation, however, some important measures and steps should be adopted: (1) The producers must strictly execute manufacturing procedure to reduce microbiological contamination thus lower the applied dose for sterilization which is recommended to be controlled under 5, 7 or 10 kGy for dry herb, 7 kGy for herbal medicine and 5 kGy for some special herbal medicine; (2) Herb to be sterilized by γ-irradiation should exist in possible dry state; (3) Powder TCMs is recommended to mix with honey forming bolus, which can minimize the decomposition of herb

  13. Investigation of radiation gamma-sterilization effect on sodium alginate hydrogels

    International Nuclear Information System (INIS)

    Valueva, M.I.; Oltarzhevskaya, N.D.; Maksimova, Yu.S.; Fenin, A.A.

    2012-01-01

    The effect of gamma-radiation in doses ensuring materials sterility (6-15 kGy) on alginate hydrogels is studied. For conservation of polymer solutions viscosity after sterilization it is necessary to introduce in polymer matrix different additives inhibiting the radiolysis process. Substances-antioxidants (aqueous extracts of sea-buckthorn and blueberry), polyvinylpyrrolidone, pectin, polyethylene oxides with molecular mass from 400 to 40000 have been studied as the additives. The additives selected have the positive effect on the result of alginate hydrogels sterilization. It is established, that the problem of human tissue radiation protection is closely connected with the problem of biopolymer hydrogels radiation protection [ru

  14. Plasma Sterilization: New Epoch in Medical Textiles

    Science.gov (United States)

    Senthilkumar, P.; Arun, N.; Vigneswaran, C.

    2015-04-01

    Clothing is perceived to be second skin to the human body since it is in close contact with the human skin most of the times. In hospitals, use of textile materials in different forms and sterilization of these materials is an essential requirement for preventing spread of germs. The need for appropriate disinfection and sterilization techniques is of paramount importance. There has been a continuous demand for novel sterilization techniques appropriate for use on various textile materials as the existing sterilization techniques suffer from various technical and economical drawbacks. Plasma sterilization is the alternative method, which is friendlier and more effective on the wide spectrum of prokaryotic and eukaryotic microorganisms. Basically, the main inactivation factors for cells exposed to plasma are heat, UV radiation and various reactive species. Plasma exposure can kill micro-organisms on a surface in addition to removing adsorbed monolayer of surface contaminants. Advantages of plasma surface treatment are removal of contaminants from the surface, change in the surface energy and sterilization of the surface. Plasma sterilization aims to kill and/or remove all micro-organisms which may cause infection of humans or animals, or which can cause spoilage of foods or other goods. This review paper emphasizes necessity for sterilization, essentials of sterilization, mechanism of plasma sterilization and the parameters influencing it.

  15. Women plan condom use after sterilization.

    Science.gov (United States)

    1998-12-01

    Sexual sterilization is highly effective in preventing pregnancy, but it does not protect against sexually transmitted diseases (STDs). People who accept sterilization as their method of family planning therefore need to be encouraged to protect themselves against HIV/AIDS and STDs even after they have been sterilized. Since women return less often to family planning providers following their sterilization procedure, they need to be advised to protect themselves against HIV and STDs before the sterilization is performed. 42% of the 2782 women who underwent tubal sterilizations at the Baylor College of Medicine in Houston during 1991-96 indicated their intention in a cross-sectional study to use condoms after sterilization. 20% of all respondents, aged 18-51 years, had a known risk factor for HIV, and almost 25% reported regular condom use for contraception or disease protection during the 3 months before sterilization. Planned condom use increased from 32% in 1991 to 51% in 1996, irrespective of age, marital status, or ethnic background. Of the 646 women who used condoms before being sterilized, almost half indicated no plans to do so after the procedure. The following factors were associated with condom use: relatively younger age, black ethnicity, unmarried status, history of previous STD, no steady partner, having a higher number of previous sex partners, past use of condoms to prevent disease transmission, and lack of partner involvement in the decision to undergo sterilization.

  16. Regret following female sterilization in Slovenia.

    Science.gov (United States)

    Becner, Anja; Turkanović, Anela Bečić; But, Igor

    2015-07-01

    To estimate the regret rate and risk factors for regret among women who have undergone sterilization. A retrospective study was conducted among all women who underwent a sterilization procedure at the University Medical Center Maribor, Maribor, Slovenia, in 2008-2012. Identified women were contacted and asked to complete an online questionnaire assessing regret and symptoms associated with depression. Among 714 identified women, 308 (43.1%) completed the questionnaire. Four (1.3%) participants reported regret, and 9 (2.9%) reported that they would not opt for sterilization again, all of whom had post-sterilization problems. Such problems were significantly associated with participants reporting that they would not opt for sterilization again (P=0.003). Additionally, women who would not choose sterilization again had significantly higher scores on the depressive scale used than did those who would undergo sterilization again (P=0.028). Few women report regret after tubal sterilization in Slovenia. However, an additional consultation on post-sterilization problems and depressive disorder before sterilization might minimize the risk of regret. Copyright © 2015 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  17. Comparative analysis of ampoules and vials in sterile and conventional packaging as to microbial load and sterility test.

    Science.gov (United States)

    Freitas, Raphael Ribeiro de Aquino; Tardelli, Maria Angela

    2016-05-24

    To compare sterility and microbial (bacteria and fungi) load in the outer part of hyperbaric bupivacaine (Neocaína®) in ampoule and bupivacaine in vial, in conventional and sterile pack formulations. The sterile packs were divided into two groups: G1 (n=16) with ampoules and G2 (n=16) with vials. Conventional formulations were divided into two groups, being G3 (n=16) with ampoules and G4 (n=16) with vials. The ampoules and vials were opened and had their content drawn. The empty bottles were then placed in sterile plastic bags and sent for analysis of microbial load (bacteria and fungi) and sterility testing. Data were analyzed using the χ2 test with Yates correction, and 95% confidence interval. G1 and G2 showed no bacterial growth when compared to conventional groups (pcontamination of the anesthetic solution. Comparar a esterilidade e a carga microbiana (bactérias e fungos) da parte externa dos frascos de envasamento de bupivacaína hiperbárica (Neocaína®) em ampola e bupivacaína em frasco-ampola das apresentações convencional e estéril (sterile pack). As apresentações estéreis (sterile pack) foram distribuídas em dois grupos, sendo que o G1 (n=16) continha as ampolas e o G2 (n=16), os frascos-ampola. As apresentações convencionais foram distribuídas em dois grupos, a saber G3 (n=16) com as ampolas e G4 (n=16) com os frascos-ampola. As ampolas e os frascos-ampolas eram abertos e tinham seu conteúdo aspirado. Os frascos vazios eram, então, acondicionados em sacos plásticos estéreis e enviados para análise quanto à carga microbiana (bactérias e fungos), bem como para o teste de esterilidade. Os dados foram analisados por meio do teste χ2 com correção Yates com intervalo de confiança de 95%. Os grupos G1 e G2 não apresentaram crescimento bacteriano quando comparado aos grupos convencionais (p<0,001). O microbiano mais comum nas amostras convencionais foi o Staphylococcus aureus. Não houve crescimento de fungos em nenhum dos grupos. O

  18. Effects of Temperature on Hybrid Lens Performance

    Science.gov (United States)

    Askins, Steve; Victoria, Marta; Herrero, Rebeca; Domínguez, César; Antón, Ignacio; Sala, Gabriel

    2011-12-01

    In hybrid Silicone-on-glass Fresnel lenses, an optical silicone is molded onto a glass substrate and forms the Fresnel structure. These lenses offer a cost effective solution as a primary optical element in point-focus concentrator photovoltaic modules, as well as performance advantages. However, these lenses have a high performance variation with temperature due both to the change in index of refraction of silicone as well as to deformations in the facets caused by coefficient of thermal expansion (CTE) mismatch. In this study we perform measurements of the light flux at the focal plane of a family of SOG lenses, varying temperature and lens-to-receiver distances. The effect of varying silicone cure temperature and the depth of the silicone between the lens and the glass substrate on temperature dependence was investigated. A preliminary computer model of this behavior is presented.

  19. Lens regeneration in New Zealand albino rabbits after endocapsular cataract extraction.

    Science.gov (United States)

    Gwon, A; Gruber, L; Mantras, C; Cunanan, C

    1993-05-01

    To evaluate the regenerative capacity of the adult rabbit lens after removal of a Concanavalin A-induced posterior subcapsular cataract. Cataractogenesis was induced by intravitreal injection of Concanavalin A in adult New Zealand albino rabbits. At 7 mo postinjection, the cataracts were removed. Endocapsular lens extraction was performed by phacoemulsification and irrigation/aspiration with Balanced Salt Solution. Postoperatively, lens regeneration was first noted in the Balanced Salt Solution normal lens group at 3 weeks and the Concanavalin A cataract group at 6 weeks. By the 3-mo postoperative examination, lens regrowth, measured by digital image analysis, filled 74.5% of the capsule bag in the Balanced Salt Solution normal lens group and 46.6% in the Concanavalin A cataract group. In the latter group, less lens material was regenerated and at a slower rate than in eyes with extraction of a normal lens. This experimental model is the first to show that lens regeneration can occur after removal of cataracts secondary to inflammation.

  20. Experimental bounds on sterile neutrino mixing angles

    CERN Document Server

    Ruchayskiy, Oleg

    2012-01-01

    We derive bounds on the mixing between the left-chiral ("active") and the right-chiral ("sterile") neutrinos, provided from the combination of neutrino oscillation data and direct experimental searches for sterile neutrinos. We demonstrate that the mixing of sterile neutrinos with any flavour can be significantly suppressed, provided that the angle theta_13 is non-zero. This means that the lower bounds on sterile neutrino lifetime, coming from the negative results of direct experimental searches can be relaxed (by as much as the order of magnitude at some masses). We also demonstrate that the results of the negative searches of sterile neutrinos with PS191 and CHARM experiments are not applicable directly to the see-saw models. The reinterpretation of these results provides up to the order of magnitude stronger bounds on sterile neutrino lifetime than previously discussed in the literature. We discuss the implications of our results for the Neutrino Minimal Standard Model (the NuMSM).

  1. Birth planning and sterilization in China.

    Science.gov (United States)

    Short, S E; Linmao, M; Wentao, Y

    2000-11-01

    Sterilization is the most prevalent method of contraception in China. Approximately half of all women of reproductive age report that they or their husbands are sterilized. Using data from the China Health and Nutrition Survey we describe patterns of sterilization in eight Chinese provinces. With a discrete-time event history model we investigate the link between characteristics of local birth planning policy and the risk of sterilization. After controlling for parity, the risk of sterilization is highest in communities where birth planning policy is least strong as measured by exceptions to the one-child policy. These results suggest that couples with more flexibility in family building may have less control over contraceptive method use. Other factors affecting the risk of sterilization are a woman's age, parity, and whether or not she has a son. Our results emphasize the importance of taking into account multiple dimensions of reproductive behaviour when assessing one-child policy changes.

  2. Surgical Sterilization, Regret, and Race: Contemporary Patterns*

    Science.gov (United States)

    Shreffler, Karina M.; McQuillan, Julia; Greil, Arthur L.; Johnson, David R.

    2014-01-01

    Surgical sterilization is a relatively permanent form of contraception that has been disproportionately used by Black, Hispanic, and Native American women in the United States in the past. We use a nationally representative sample of 4,609 women ages 25 to 45 to determine whether sterilization continues to be more common and consequential by race for reproductive-age women. Results indicate that Native American and Black women are more likely to be sterilized than non-Hispanic White women, and Hispanic and Native American women are more likely than non-Hispanic White women to report that their sterilization surgeries prevent them from conceiving children they want. Reasons for sterilization differ significantly by race. These findings suggest that stratified reproduction has not ended in the United States and that the patterns and consequences of sterilization continue to vary by race. PMID:25592919

  3. Surgical sterilization, regret, and race: contemporary patterns.

    Science.gov (United States)

    Shreffler, Karina M; McQuillan, Julia; Greil, Arthur L; Johnson, David R

    2015-03-01

    Surgical sterilization is a relatively permanent form of contraception that has been disproportionately used by Black, Hispanic, and Native American women in the United States in the past. We use a nationally representative sample of 4592 women ages 25-45 to determine whether sterilization continues to be more common and consequential by race for reproductive-age women. Results indicate that Native American and Black women are more likely to be sterilized than non-Hispanic White women, and Hispanic and Native American women are more likely than non-Hispanic White women to report that their sterilization surgeries prevent them from conceiving children they want. Reasons for sterilization differ significantly by race. These findings suggest that stratified reproduction has not ended in the United States and that the patterns and consequences of sterilization continue to vary by race. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Radiating sterilization of the venom of snake

    International Nuclear Information System (INIS)

    Abiyev, H.A.; Topchiyeva, Sh.A.; Rustamov, V.R.

    2006-01-01

    Full text: Water solutions of venoms are unstable and they lose toxicity in some day. Snake venoms inactivate under action of some physical factors: the UV-irradiation, x-rays beams. The purpose of the present work was sterilization of venom Vipera lebetina obtusa under influence of small dozes γ-radiations. Object of research was integral venom of adult individuals. Transcaucasian viper, and also the water solutions of venom irradiated with small dozes scale of radiation. An irradiation of venom carried out to radioisotope installation 60NI. For experiment tests of dry venom, and also their water solutions have been taken. Water solutions of venom have been subjected -radiation up to dozes 1.35, 2.7, 4.05, 5.4 kGr simultaneously dry venom of vipers was exposed -radiation before absorption of a doze 5.4 kGr. In comparative aspect action scale of radiation on ultra-violet spectra of absorption of venom was studied. Ultra-violet spectra venom have been taken off on device Specord UV-VIS. In 12 months after an irradiation spectra of absorption of venom have been repeatedly taken off. In spectra irradiated dry and solutions of venom new maxima of absorption have been revealed in the field of 285 nm and 800 nm describing change of toxicity. It is shown, that the increase in absorption of a doze of radiation occurs decrease of intensity of strips of absorption reduction of intensity of absorption.It is revealed at 260 and 300 nm testifying to course of biochemical reactions of separate enzymes zootoxins. It is necessary to note, that at comparison of intensity of absorption of control samples of poison with irradiated up to dozes 1.35 kGr it has not been revealed essential changes. The subsequent increase in a doze scale of radiation up to 2.7, 4.05, 5.4 kGr promotes proportional reduction of intensity of the absorption, describing toxicity of snake venom. At repeated (later 12 months) measurement of the irradiated water solutions of venom are not revealed changes in

  5. Incorporation of Hands-On Sterile Technique Instruction in an Introductory Pharmacy Practice Experience

    Science.gov (United States)

    Cruthirds, Danielle; Coward, Lori

    2015-01-01

    Objective. To examine sterile technique and basic sterile compounding procedures among third-year pharmacy students. Design. Third year pharmacy students participating in an introductory pharmacy practice experience (IPPE) in 2012 (n=126) and 2013 (n=119) performed a modified low-risk compounded sterile product (CSP) media fill challenge test, then prepared a 5 mg/mL vancomycin solution that was subsequently analyzed for accuracy. Assessment. To identify deficiencies in sterile procedures, students were observed while performing a modified low-risk CSP media fill challenge test. In the first year of conducting the challenge test (2012), 3 deficiencies were identified: hand washing before compounding, cleaning items with alcohol prior to start, and cleaning work area upon completion. In 2013, significant improvements were observed in these 3 areas after students watched a demonstration video. Examination of CSPs revealed less than 1% contamination in both years. Analysis of compounded vancomycin solutions showed that 84% and 71% of students prepared solutions in 2012 and 2013, respectively, were within 10% of the targeted final concentration. Conclusion. Hands-on sterile compounding exercises are typically delivered early in the pharmacy professional curriculum with minimal reinforcement in subsequent years. Providing opportunities for advanced pharmacy students to refresh and practice sterile compounding procedures allows students to refine their skills before entering pharmacy practice. PMID:25861109

  6. EB surface sterilization of food material

    International Nuclear Information System (INIS)

    Kaneko, H.; Mizutani, A.; Kato, K.; Nishikimi, T.; Taniguchi, S.

    2001-01-01

    In this paper, we introduce a food irradiation with low energetic, lower than 300keV, electrons (so-called SOFT ELECTRON) as a rather new method of food sterilization. It is also a physical sterilization method, and free from the problems mentioned above. Low energetic electrons have small penetration power (50-200micron) through raw materials, and by selecting a proper energy of electrons we can sterilize only the surfaces or skins of target materials

  7. Sterilization of oils: Data to support the use of a continuous point-of-use sterilizer.

    Science.gov (United States)

    Bader, F G; Boekeloo, M K; Graham, H E; Cagle, J W

    1984-08-01

    The continuous slow feed of animal and vegetable oils is frequently found to be an economically attractive method for maintaining antibiotic fermentations at a highly productive rate. The sterilization of oil feeds can present a major problem in the production plant. In this article, we present data and methodology on the kinetics of the thermal sterilization of No. 2 lard oil and soybean oil. It was also determined that dry heat sterilization condition could occur if dry spores were added to dry oil. This condition could only be partially alleviated by the addition of water to the oil. The theory and design of a small tubular coil continuous sterilizer for sterilizing oils at the point of use is also presented. This type of sterilizer is economical and versatile and simplifies control and instrument requirements. It provides a realistic alternative to the use of sterile feed tanks and sterile headers.

  8. Probabilistic model for sterilization of food

    International Nuclear Information System (INIS)

    Chepurko, V.V.; Malinovskij, O.V.

    1986-01-01

    The probabilistic model for radiation sterilization is proposed based on the followng suppositions: (1) initial contamination of a volume unit of the sterilized product m is described by the distribution of the probabilities q(m), (2) inactivation of the population from m of microorganisms is approximated by Bernoulli test scheme, and (3) contamination of unit of the sterilized product is independent. The possibility of approximation q(m) by Poisson distribution is demonstrated. The diagrams are presented permitting to evaluate the dose which provides the defined reliability of sterilization of food for chicken-gnotobionts

  9. Currently available devices for female sterilization.

    Science.gov (United States)

    Chapman, Lynne; Magos, Adam

    2005-09-01

    Sterilization is now the method of family planning most commonly used in the world. Over the last 150 years, research has evolved in the search for the ideal method of female sterilization. The procedure should ideally have high efficacy, be readily accessible and be personally and culturally acceptable. The method should be simple, quick, easily learned and be able to be performed in an outpatient setting without general anesthesia. The most common and effective method for sterilization has, thus far, been via the laparoscopic route. Hysteroscopic sterilization, however, potentially fulfills many of these ideal criteria, but until recently has remained more of a concept than a reality.

  10. Sterile neutrino dark matter with supersymmetry

    Science.gov (United States)

    Shakya, Bibhushan; Wells, James D.

    2017-08-01

    Sterile neutrino dark matter, a popular alternative to the WIMP paradigm, has generally been studied in non-supersymmetric setups. If the underlying theory is supersymmetric, we find that several interesting and novel dark matter features can arise. In particular, in scenarios of freeze-in production of sterile neutrino dark matter, its superpartner, the sterile sneutrino, can play a crucial role in early Universe cosmology as the dominant source of cold, warm, or hot dark matter, or of a subdominant relativistic population of sterile neutrinos that can contribute to the effective number of relativistic degrees of freedom Neff during big bang nucleosynthesis.

  11. Seeking sterile neutrinos in Finslerian cosmology

    Science.gov (United States)

    Wang, Deng; Meng, Xin-He

    2017-11-01

    For the first time, to search for sterile neutrinos in the framework of Finler geometry, we constrain four cosmological models using the most stringent constraint we can provide so far. We find that the Finslerian massless sterile neutrino model can, respectively, give a better cosmological fit to data and alleviate the current H_0 tension more effectively than the other three models. For the Finslerian massless sterile neutrino model, we obtain the constraint N_eff=3.237^{+0.092}_{-0.185}, which is consistent with Δ N_eff > 0 at the 1.03σ confidence level (CL). This gives a very weak hint of massless sterile neutrinos and may imply the non-existence of massless sterile neutrinos in the Finslerian cosmological setting. For the Finslerian massive sterile neutrino model, we obtain the constraints N_eff=3.143^{+0.064}_{-0.066}, which favors Δ N_eff > 0 at the 1.47σ CL, and m_{ν , sterile}^eff sterile neutrinos are also non-existent in the Finslerian scenarios. Consequently, one may conclude that the sterile neutrinos are possibly non-existent in the Finslerian universe. Our results are compatible with the recent results of the neutrino oscillation experiments implemented by the Daya Bay and MINOS collaborations and the cosmic ray one carried out by the IceCube collaboration.

  12. Steam sterilization and automatic dispensing of [{sup 18}F]fludeoxyglucose (FDG) for injection

    Energy Technology Data Exchange (ETDEWEB)

    Karwath, Pascal [Department of Nuclear Medicine, University of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany) and MC-Pharma GmbH (MCP), Bonn (Germany)]. E-mail: p.karwath@uni-bonn.de; Sartor, Johannes [MC-Pharma GmbH (MCP), Bonn (Germany); Gries, Wolfgang [MC-Pharma GmbH (MCP), Bonn (Germany); Wodarski, Christine [MC-Pharma GmbH (MCP), Bonn (Germany); Dittmar, Claus [MC-Pharma GmbH (MCP), Bonn (Germany); Biersack, Hans J. [Department of Nuclear Medicine, University of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany); Guhlke, Stefan [Department of Nuclear Medicine, University of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany) and MC-Pharma GmbH (MCP), Bonn (Germany)]. E-mail: stefan.guhlke@ukb.uni-bonn.de

    2005-04-01

    For the purpose of implementing steam sterilization of 2-[{sup 18}F]FDG (FDG) in the final container into routine production, we have validated and established a fully automated dispensing and sterilization system, thereby considerably reducing the radiation burden to the personnel. Methods: The commercially available system combines aseptic dispensing of the product solution under a miniaturized laminar flow unit with subsequent steam sterilization, realized by heating of the product in the final containers by an autoclave included in the dispensing unit, thus incorporating current pharmaceutical manufacturing standards for the production of parental radiopharmaceuticals. The efficiency of the used sterilization cycle, the stability of FDG under the conditions of sterilization and the stability of the final product towards radiolysis was investigated with respect to various pH-formulations. Results: The system was found to be fully valid for filling of vials in a laminar flow class A (US-class 100) environment and for sterilization of FDG in the final container. The pH for sterilizing FDG solutions must be slightly acidic to avoid decomposition. A pH of 5.5 appears to be optimal and gives FDG of very high radiochemical purity ({approx}99%). In addition, radiolysis of FDG in solutions of high activity concentration was significantly lower at pH 5.5 than at neutral pH. Conclusion: Terminal sterilization enables the production of FDG in full compliance with GMP-regulations even in Class C or D (US class 10,000 or 100,000) laboratories.

  13. Steam sterilization and automatic dispensing of [18F]fludeoxyglucose (FDG) for injection

    International Nuclear Information System (INIS)

    Karwath, Pascal; Sartor, Johannes; Gries, Wolfgang; Wodarski, Christine; Dittmar, Claus; Biersack, Hans J.; Guhlke, Stefan

    2005-01-01

    For the purpose of implementing steam sterilization of 2-[ 18 F]FDG (FDG) in the final container into routine production, we have validated and established a fully automated dispensing and sterilization system, thereby considerably reducing the radiation burden to the personnel. Methods: The commercially available system combines aseptic dispensing of the product solution under a miniaturized laminar flow unit with subsequent steam sterilization, realized by heating of the product in the final containers by an autoclave included in the dispensing unit, thus incorporating current pharmaceutical manufacturing standards for the production of parental radiopharmaceuticals. The efficiency of the used sterilization cycle, the stability of FDG under the conditions of sterilization and the stability of the final product towards radiolysis was investigated with respect to various pH-formulations. Results: The system was found to be fully valid for filling of vials in a laminar flow class A (US-class 100) environment and for sterilization of FDG in the final container. The pH for sterilizing FDG solutions must be slightly acidic to avoid decomposition. A pH of 5.5 appears to be optimal and gives FDG of very high radiochemical purity (∼99%). In addition, radiolysis of FDG in solutions of high activity concentration was significantly lower at pH 5.5 than at neutral pH. Conclusion: Terminal sterilization enables the production of FDG in full compliance with GMP-regulations even in Class C or D (US class 10,000 or 100,000) laboratories

  14. Compliance among soft contact lens wearers.

    OpenAIRE

    Kuzman, Tomislav; Barišić Kutija, Marija; Masnec, Sanja; Jandroković, Sonja; Mrazovac, Danijela; Jurišić, Darija; Škegro, Ivan; Kalauz, Miro; Kordić, Rajko

    2014-01-01

    Contact lens compliance is proven to be crucial for preventing lens wear-related complications because of the interdependence of the steps in lens care regime and their influence on lens system microbial contamination. Awareness of the patients' lens handling compliance as well as correct recognition of non-compliant behaviours is the basis for creating more targeted strategies for patient education. The aim of this study was to investigate compliance among soft contact lens (SCL) wearers in ...

  15. Iris reconstruction using autologous iris preserved in cold balanced salt solution for 8 hours in iatrogenic total iridodialysis during cataract surgery: a case report.

    Science.gov (United States)

    Bang, Seung Pil; Jun, Jong Hwa

    2017-04-04

    A large iris defect or extensive iridodialysis can be an intractable cause of visual disturbance, photophobia, glare, monocular diplopia, or cosmetic deformity. The implantation of an artificial iris substitute could be an effective option, but this can cause a reduction in endothelial cell density. We succeeded in the anatomical restoration of iris tissue that was totally dialyzed out of the eye, and was preserved in cold balanced salt solution for 8 h. Engrafted iris tissue was maintained within the aqueous humor. A 71-year-old man was referred to our clinic for management of an iatrogenic total iridodialysis. The totally dialyzed iris tissue was immediately preserved in sterile cold balanced salt solution and packed in a sterile biopsy bottle that was surrounded with ice cubes. Under general anesthesia, a pars plana vitrectomy was performed to remove the remaining lens cortex and vitreous fiber anterior to the equator. A sulcus-positioned intraocular lens (IOL) was repositioned and fixed by ab externo scleral sutures. Preserved iris tissue was inserted and ironed using both iris spatula and ocular viscoelastic devices. Five-point ab interno scleral sutures were made 1.0 mm posterior to the limbus. The engrafted iris was successfully maintained for 6 months and did not undergo any atrophic change or depigmentation, which may be caused by primary implantation failure due to a blocked blood supply.

  16. Adaptive neuro-fuzzy estimation of optimal lens system parameters

    Science.gov (United States)

    Petković, Dalibor; Pavlović, Nenad T.; Shamshirband, Shahaboddin; Mat Kiah, Miss Laiha; Badrul Anuar, Nor; Idna Idris, Mohd Yamani

    2014-04-01

    Due to the popularization of digital technology, the demand for high-quality digital products has become critical. The quantitative assessment of image quality is an important consideration in any type of imaging system. Therefore, developing a design that combines the requirements of good image quality is desirable. Lens system design represents a crucial factor for good image quality. Optimization procedure is the main part of the lens system design methodology. Lens system optimization is a complex non-linear optimization task, often with intricate physical constraints, for which there is no analytical solutions. Therefore lens system design provides ideal problems for intelligent optimization algorithms. There are many tools which can be used to measure optical performance. One very useful tool is the spot diagram. The spot diagram gives an indication of the image of a point object. In this paper, one optimization criterion for lens system, the spot size radius, is considered. This paper presents new lens optimization methods based on adaptive neuro-fuzzy inference strategy (ANFIS). This intelligent estimator is implemented using Matlab/Simulink and the performances are investigated.

  17. Light Sterile Neutrinos: A White Paper

    DEFF Research Database (Denmark)

    Abazajian, K. N.; Acero, M. A.; Agarwalla, S. K.

    2012-01-01

    This white paper addresses the hypothesis of light sterile neutrinos based on recent anomalies observed in neutrino experiments and the latest astrophysical data.......This white paper addresses the hypothesis of light sterile neutrinos based on recent anomalies observed in neutrino experiments and the latest astrophysical data....

  18. Sodium hypochlorite sterilization of culture medium in ...

    African Journals Online (AJOL)

    With the purpose of finding an alternative to thermal sterilization, this research aimed at assessing the efficiency and ideal concentration of sodium hypochlorite for sterilization of culture media and glassware used during rooting of micropropagated Gerbera hybrida cv. Essandre. Two experiments were carried out. In the first ...

  19. Guidelines for pre-sterilization counseling.

    Science.gov (United States)

    1996-09-01

    The following guidelines for pre-sterilization counseling have been adopted by the Association for Voluntary Surgical Contraception: 1) emphasize that sterilization is permanent; 2) involve both partners in the decision making and present male sterilization as a viable option; 3) even if sterilization is requested, also present the range of long-term reversible methods available; 4) inform the client of failure rates associated with female sterilization and the associated risk of ectopic pregnancy; 5) emphasize that sterilization provides no protection against sexually transmitted diseases, including human immunodeficiency virus; 6) screen candidates for risk factors of post-sterilization regret, including young age and sterilization at the time of abortion or delivery; 7) fully explain the surgical procedure, preoperative instructions, surgical site, timing of the procedure, type of anesthesia, surgical risks, and length of recovery; 8) describe the possibility of unrelated changes in menstruation; 9) answer all questions; 10) discuss the positive effects on sexuality once concerns about unwanted pregnancy are removed; and 11) provide printed educational materials that the couple can review privately.

  20. Cosmology seeking friendship with sterile neutrinos

    DEFF Research Database (Denmark)

    Hamann, Jan; Hannestad, Steen; Raffelt, G.G.

    2011-01-01

    Precision cosmology and big-bang nucleosynthesis mildly favour extra radiation in the universe beyond photons and ordinary neutrinos, lending support to the existence of low-mass sterile neutrinos. We present bounds on the common mass scale ms and effective number Ns of thermally excited sterile...

  1. Iran eases limits on sterilization.

    Science.gov (United States)

    Roudi, N

    1991-03-01

    The government of Iran announced in November 1990, in an abrupt reversal of previous policies, the legislation of sterilization and its provision free-of-charge upon request, as well as the distribution of other contraceptive gratis. At the time of the Islamic Revolution in 1979 the government adopted a pronatalist policy, family planning programs were interrupted, legal ages of marriage were lowered, and barriers against polygamy were loosened. Iran had a 3.5% growth rate in 1990 and a total fertility rate of 6.3 lifetime births/woman. After the end of the war between Iran and Iraq in 1988, the population explosion became an obstacle to reconstruction. In 1950, the population numbered 14.2 million; by 1970 it had doubled to 28.4 million. In 1990, the country had 54.6 million people. According to a 1990 UN assessment the population will soar to 100 million by 2020. Over 8 million live in Tehran where overcrowding, traffic congestion, air pollution, and high living costs are the norm. the 1989 National Birth Control Policy Summary adopted targets to reduce the average number of lifetime births per woman to 4 children and natural growth rate to 2.3% by 2011, and to provide family planning to 24% of reproductive-age women whereby 1 million conceptions would be prevented. Indirect measures to curb fertility include raising literacy promoting the education of girls, improving the status and health conditions of women, and reducing maternal and child mortality. A media campaign has started to encourage a small family model. The low legal, social, educational, and employment status of women poses obstacles to this plan, however, the revision of laws that conflict with these goals has been urged. In other Islamic countries such as Turkey, Tunisia, Indonesia, Pakistan, and Bangladesh, female sterilization is legal. Abortion in Iran remains banned except for saving the life of the mother.

  2. Federally funded sterilization: time to rethink policy?

    Science.gov (United States)

    Borrero, Sonya; Zite, Nikki; Creinin, Mitchell D

    2012-10-01

    In the 1970s, concern about coercive sterilization of low-income and minority women in the United States led the US Department of Health, Education, and Welfare to create strict regulations for federally funded sterilization procedures. Although these policies were instituted to secure informed consent and protect women from involuntary sterilization, there are significant data indicating that these policies may not, in fact, ensure that consent is truly informed and, further, may prevent many low-income women from getting a desired sterilization procedure. Given the alarmingly high rates of unintended pregnancy in the United States, especially among low-income populations, we feel that restrictive federal sterilization policies should be reexamined and modified to simultaneously ensure informed decision-making and honor women's reproductive choices.

  3. Status of the effectiveness of contact lens disinfectants in Malaysia against keratitis-causing pathogens.

    Science.gov (United States)

    Abjani, Farhat; Khan, Naveed Ahmed; Jung, Suk Yul; Siddiqui, Ruqaiyyah

    2017-12-01

    The aim of this study was (i) to assess the antimicrobial effects of contact lens disinfecting solutions marketed in Malaysia against common bacterial eye pathogens and as well as eye parasite, Acanthamoeba castellanii, and (ii) to determine whether targeting cyst wall would improve the efficacy of contact lens disinfectants. Using ISO 14729 Stand-Alone Test for disinfecting solutions, bactericidal and amoebicidal assays of six different contact lens solutions including Oxysept ® , AO SEPT PLUS, OPTI-FREE ® pure moist ® , Renu ® fresh™, FreshKon ® CLEAR and COMPLETE RevitaLens™ were performed using Manufacturers Minimum recommended disinfection time (MRDT). The efficacy of contact lens solutions was determined against keratitis-causing microbes, namely: Pseudomonas aeruginosa, Methicillin-resistant Staphylococcus aureus, Streptococcus pyogenes, Streptococcus pneumoniae, and Acanthamoeba castellanii. In addition, using chlorhexidine as an antiamoebic compound and cellulase enzyme to disrupt cyst wall structure, we determined whether combination of both agents can enhance efficacy of marketed contact lens disinfectants against A. castellanii trophozoites and cysts, in vitro. The results revealed that all contact lens disinfectants tested showed potent bactericidal effects exhibiting 100% kill against all bacterial species tested. In contrast, none of the contact lens disinfectants had potent effects against Acanthamoeba cysts viability. When tested against trophozoites, two disinfectants, Oxysept Multipurpose and AO-sept Multipurpose showed partial amoebicidal effects. Using chlorhexidine as an antiamoebic compound and cellulase enzyme to disrupt cyst wall structure, the findings revealed that combination of both agents in contact lens disinfectants abolished viability of A. castellanii cysts and trophozoites. Given the inefficacy of contact lens disinfectants tested in this study, these findings present a significant concern to public health. These

  4. Application of the BacT/ALERTR 3D system for sterility testing of injectable products

    Directory of Open Access Journals (Sweden)

    Adriana Bugno

    2015-09-01

    Full Text Available Sterility testing as described in the pharmacopoeia compendia requires a 14-day incubation period to obtain an analytical result. Alternative methods that could be applied to evaluating product sterility are especially interesting due to the possibility of reducing this incubation period and thus the associated costs. The aims of this study were to evaluate the performance of the BacT/ALERTR 3D system in detecting microorganisms in large-volume parenteral solutions that were intentionally contaminated and to compare this system to pharmacopoeia sterility testing using the membrane filtration method. The results indicated that there were no significant differences between the methods regarding the ability to detect microbial contamination; however, detection with the BacT/ALERTR 3D system was faster compared to the pharmacopoeia method. Therefore, the BacT/ALERTR 3D system is a viable alternative for assessing the sterility of injectable products.

  5. Application of the BacT/ALERTR 3D system for sterility testing of injectable products

    Science.gov (United States)

    Bugno, Adriana; Lira, Rodolfo Santos; Oliveira, Wesley Anderson; Almodovar, Adriana Aparecida Buzzo; Saes, Deborah Pita Sanches; de Jesus Andreoli Pinto, Terezinha

    2015-01-01

    Sterility testing as described in the pharmacopoeia compendia requires a 14-day incubation period to obtain an analytical result. Alternative methods that could be applied to evaluating product sterility are especially interesting due to the possibility of reducing this incubation period and thus the associated costs. The aims of this study were to evaluate the performance of the BacT/ALERTR 3D system in detecting microorganisms in large-volume parenteral solutions that were intentionally contaminated and to compare this system to pharmacopoeia sterility testing using the membrane filtration method. The results indicated that there were no significant differences between the methods regarding the ability to detect microbial contamination; however, detection with the BacT/ALERTR 3D system was faster compared to the pharmacopoeia method. Therefore, the BacT/ALERTR 3D system is a viable alternative for assessing the sterility of injectable products. PMID:26413055

  6. Chemo sterilization of the sugarcane borer Diatraea saccharalis (Fabricius, 1794) (Lepidoptera: Crambidae) with sugar solution bait and insecticides of insect growth regulators group; Esterilizacao quimica da broca da cana-de-acucar Diatraea saccharalis (Fabricius, 1794) (Lepidoptera: Crambidae) atraves de isca com melaco e inseticidas do grupo dos reguladores de crescimento de insetos

    Energy Technology Data Exchange (ETDEWEB)

    Sazaki, Catia Sumie Shimatai. E-mail csazaki@yahoo.com.br

    2006-07-01

    The sugarcane borer Diatraea saccharalis (Fabricius, 1794) (Lepidoptera: Crambidae) is an important pest in Brazilian sugarcane crops. Currently, biological control is the most frequently used method for controlling D saccharalis. However, in several locations, the parasitoid Cotesia flavipes (Cameron) (Hymenoptera: Braconidae) has not been effective for controlling this pest, and it has been recorded infestation intensity above 25%. In this context, the Sterile Insect Technique could be an additional control method in Integrated Pest Management, because it is compatible with other control methods. The use of insecticides that interferes in hormone homeostasis involved in the ecdyse's process with exogenous hormone sources or synthetic analogues (agonists or antagonists) can result in the interruption of the reproductive process or abnormal development of the insect?s embryo. Then, the objective of this study was to evaluate the insecticides that regulates the insect growth on the D. saccharalis reproduction. The insecticides tested were: chlorfluazuron (1,0 and 1,5 g a.i./L), diflubenzuron (3,75; 5,0 and 7,5 g a.i./L), flufenoxuron (1,0 g a.i./L), lufenuron (0,75; 1,0 and 2,0 g a.i./L), novaluron (0,5 and 1,0 g a.i./L) pyriproxyfen (1,0; 1,5; 1,8 and 2,0 g a.i./L) and teflubenzuron (1,5; 3,0 and 6,0 g a.i./L). Each insecticide was provided to 1-day moths on soaked cotton with a sugar solution at 10% as a bait. All treatments, except to of the lowest concentration of lufenuron (0,75 g a.i./L) decreased the egg production in relation to the control. Flufenoxuron (1,00 g g a.i./L) and chlorfluazuron (1,50 g a.i./L) decreased the lifespan of both sexes treated by ingestion. Lufenuron (2,0 g a.i./L), novaluron (1,0 g a.i./L) and teflubenzuron (3,0 g a.i./L) decreased the male's lifespan. The most effective treatments for sterilization were pyriproxyfen (1,8 g a.i./L and 2,0 g a.i./L) and lufenuron (2,0 g a.i./L), witch showed efficiencies greater or close to

  7. Crystalline lens radioprotectors

    International Nuclear Information System (INIS)

    Belkacemi, Y.; Pasquier, D.; Castelain, B.; Lartigau, E.; Warnet, J.M.

    2003-01-01

    During more than a half of century, numerous compounds have been tested in different models against radiation-induced cataract. In this report, we will review the radioprotectors that have been already tested for non-human crystalline lens protection. We will focus on the most important published studies in this topic and the mechanisms of cyto-protection reported in. vitro and in. vivo from animals. The most frequent mechanisms incriminated in the cyto-protective effect are: free radical scavenging, limitation of lipid peroxidation, modulation of cycle progression increase of intracellular reduced glutathione pool, reduction of DNA strand breaks and limitation of apoptotic cell death. Arnifostine (or Ethyol) and anethole dithiolethione (or Sulfarlem), already used clinically as chemo- and radio-protectants, could be further test?r for ocular radioprotection particularly for radiation-induced cataract. (author)

  8. Feasibility studies of radiation sterilization of some pharmaceutical products

    International Nuclear Information System (INIS)

    Gopal, N.G.S.; Rajagopalan, S.; Sharma, G.

    1975-01-01

    The paper deals with some studies carried out to evaluate the feasibility of radiation sterilization or treatment of some medical products and pharmaceuticals of immediate importance to their respective industries. The products include penicillin G sodium, ampicillin sodium, tetracyclin hydrochloride ointment,hydrocortisone acetate and its ointment, aqueous sodium chloride solutions (0.9 and 20%), fluorescein sodium strips, urea, ethylmorphine hydrochloride, aqueous solution of chlorobutanol and one of its commercial preparations, phenylmercuric nitrate and its aqueous solutions, aqueous solutions of methyl and propyl paraben, lactose, gum karaya, absorbent cotton and poly-(vinyl chloride) based medical products. The irradiated products have been examined for pharmacopoeial specifications wherever available. In general the products have been examined for changes in colour, pH, ultra-violet and infra-red absorption spectra. Thin-layer chromatographic analyses have been carried out to establish the purity of some of the irradiated products. The feasibility or otherwise of radiation sterilization or treatment of the various products from the physicochemical and microbiological (pharmacological) clinical considerations is also described. (author)

  9. LED surgical lighting system with multiple free-form surfaces for highly sterile operating theater application.

    Science.gov (United States)

    Liu, Peng; Zhang, Yaqin; Zheng, Zhenrong; Li, Haifeng; Liu, Xu

    2014-06-01

    Although the ventilation system is widely employed in the operating theater, a strictly sterile surgical environment still cannot be ensured because of laminar disturbance, which is mainly caused by the surgical lighting system. Abandoning traditional products, we propose an LED surgical lighting system, which can alleviate the laminar disturbance and provide an appropriate lighting condition for surgery. It contains a certain amount of LED lens units, which are embedded in the ceiling and arranged around the air supply smallpox. The LED lens unit integrated with an LED light source and a free-form lens is required to produce a uniform circular illumination with a large tolerance to the change of lighting distance. To achieve such a dedicated lens, two free-form refractive surfaces, which are converted into two ordinary differential equations by the design method presented in this paper, are used to deflect the rays. The results show that the LED surgical lighting system can provide an excellent illumination environment for surgery, and, apparently, the laminar disturbance also can be relieved.

  10. Contact Lens Wear at Altitude: Subcontact Lens Bubble Formation

    Science.gov (United States)

    1987-11-01

    incidence of (PMMA) lenses . Reported here are the results of contact lens subcontact lens bubble formation under scleral lenses at bubble studies with soft...vision from formation of large bubbles greater than 6,096 m (20,000 It). With soft contact lenses , bubble under their contact lenses . They also found...always located at the limbus and were without sequela to vision or corneal epithelial integrity. scleral lenses used by Jaeckle were permeable to gases

  11. Straylight Measurements in Contact Lens Wear

    NARCIS (Netherlands)

    van der Meulen, Ivanka J. E.; Engelbrecht, Leonore A.; van Vliet, Johannes M. J.; Lapid-Gortzak, Ruth; Nieuwendaal, Carla P.; Mourits, Maarten P.; Schlingemann, Reinier O.; van den Berg, Thomas J. T. P.

    2010-01-01

    Purpose: (1) To quantify the effect of contact lens wear on straylight in rigid and soft contact lens wearers and (2) to relate findings to morphological changes and subjective complaints. Methods: Straylight was measured using the Oculus C-Quant during contact lens wear and after contact lens

  12. Radiation sterilization of absorbent cotton and of absorbent gauze

    International Nuclear Information System (INIS)

    Hosobuchi, Kazunari; Oka, Mitsuru; Kaneko, Akira; Ishiwata, Hiroshi.

    1986-01-01

    The bioburden of absorbent cotton and of absorbent gauze and their physical and chemical characteristics after irradiation are investigated. The survey conducted on contaminants of 1890 cotton samples from 53 lots and 805 gauze samples from 56 lots showed maximum numbers of microbes per g of the cotton and gauze were 859 (an average of 21.4) and 777 (an average of 42.2), respectively. Isolation and microbiological and biochemical tests of representative microbes indicated that all of them, except one, were bacilli. The sterilization dose at 10 -6 of sterlity assurance level was found to be 2.0 Mrad when irradiated the spores loaded on paper strips and examined populations having graded D values from 0.10 to 0.28 Mrad. The sterilization dose would be about 1.5 Mrad if subjected the average numbers of contaminants observed in this study to irradiation. No significant differences were found between the irradiated samples and control up to 2 Mrad in tensile strength, change of color, absorbency, sedimentation rate, soluble substances, and pH of solutions used for immersion and other tests conventionally used. These results indicate that these products can be sterilized by irradiation. (author)

  13. Seeking sterile neutrinos in Finslerian cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Deng [Nankai University, Theoretical Physics Division, Chern Institute of Mathematics, Tianjin (China); Meng, Xin-He [Nankai University, Department of Physics, Tianjin (China)

    2017-11-15

    For the first time, to search for sterile neutrinos in the framework of Finler geometry, we constrain four cosmological models using the most stringent constraint we can provide so far. We find that the Finslerian massless sterile neutrino model can, respectively, give a better cosmological fit to data and alleviate the current H{sub 0} tension more effectively than the other three models. For the Finslerian massless sterile neutrino model, we obtain the constraint N{sub eff} = 3.237{sup +0.092}{sub -0.185}, which is consistent with ΔN{sub eff} > 0 at the 1.03σ confidence level (CL). This gives a very weak hint of massless sterile neutrinos and may imply the non-existence of massless sterile neutrinos in the Finslerian cosmological setting. For the Finslerian massive sterile neutrino model, we obtain the constraints N{sub eff} = 3.143{sup +0.064}{sub -0.066}, which favors ΔN{sub eff} > 0 at the 1.47σ CL, and m{sub ν,sterile}{sup eff} < 0.121 eV at the 2σ CL which is much tighter than the Planck results. This very tight restriction appears to indicate the massive sterile neutrinos are also non-existent in the Finslerian scenarios. Consequently, one may conclude that the sterile neutrinos are possibly non-existent in the Finslerian universe. Our results are compatible with the recent results of the neutrino oscillation experiments implemented by the Daya Bay and MINOS collaborations and the cosmic ray one carried out by the IceCube collaboration. (orig.)

  14. Forced sterilization of women as discrimination.

    Science.gov (United States)

    Patel, Priti

    2017-01-01

    There has been a long history of subjecting marginalized women to forced and coerced sterilization. In recent years, the practice has been documented in countries in North and South America, Europe, Asia, and Africa. It has targeted women who are ethnic and racial minorities, women with disabilities, women living with HIV, and poor women. A handful of courts have issued decisions on the recent forced sterilization of marginalized women finding that such actions violate the women's rights. However, they have all failed to address the women's claims of discrimination. The failure to acknowledge that forced sterilization is at its core a violation of the prohibition of discrimination undermines efforts to eradicate the practice. It further fails to recognize that coerced and forced sterilization fundamentally seeks to deny women deemed as "unworthy" the ability to procreate. Four key principles outlined in the human rights in patient care framework highlight the importance of a finding that the prohibition of discrimination was violated in cases of forced sterilization: the need to highlight the vulnerability of marginalized populations to discrimination in health care settings; the importance of the rights of medical providers; the role of the state in addressing systemic human rights violations in health care settings; and the application of human rights to patient care. Based on these principles, it is clear that finding a violation of the prohibition of discrimination in forced sterilization cases is critical in addressing the systemic nature of the practice, acknowledging the marginalization of specific groups and effectively ending forced sterilization through addressing the underlying purpose of the practice. If litigators, non-governmental organizations and judicial officers are mindful of these principles when dealing with cases of forced sterilization, it is likely that they will be better able to eradicate forced sterilization.

  15. Microscope sterility during spine surgery.

    Science.gov (United States)

    Bible, Jesse E; O'Neill, Kevin R; Crosby, Colin G; Schoenecker, Jonathan G; McGirt, Matthew J; Devin, Clinton J

    2012-04-01

    Prospective study. Assess the contamination rates of sterile microscope drapes after spine surgery. The use of the operating microscope has become more prevalent in certain spine procedures, providing superior magnification, visualization, and illumination of the operative field. However, it may represent an additional source of bacterial contamination and increase the risk of developing a postoperative infection. This study included 25 surgical spine cases performed by a single spine surgeon that required the use of the operative microscope. Sterile culture swabs were used to obtain samples from 7 defined locations on the microscope drape after its use during the operation. The undraped technician's console was sampled in each case as a positive control, and an additional 25 microscope drapes were swabbed immediately after they were applied to the microscope to obtain negative controls. Swab samples were assessed for bacterial growth on 5% sheep blood Columbia agar plates using a semiquantitative technique. No growth was observed on any of the 25 negative control drapes. In contrast, 100% of preoperative and 96% of postoperative positive controls demonstrated obvious contamination. In the postoperative group, all 7 sites of evaluation were found to be contaminated with rates of 12% to 44%. Four of the 7 evaluated locations were found to have significant contamination rates compared with negative controls, including the shafts of the optic eyepieces on the main surgeon side (24%, P = 0.022), "forehead" portion on both the main surgeon (24%, P = 0.022) and assistant sides (28%, P = 0.010), and "overhead" portion of the drape (44%, P = 0.0002). Bacterial contamination of the operative microscope was found to be significant after spine surgery. Contamination was more common around the optic eyepieces, likely due to inadvertent touching of unsterile portions. Similarly, all regions above the eyepieces also have a propensity for contamination because of unknown contact

  16. Dosimetry requirements derived from the sterilization standards

    DEFF Research Database (Denmark)

    Miller, A.

    1998-01-01

    The main standards for radiation sterilization, ISO 11137 and EN 552, rest the documentation for the properly executed sterilization process on dosimetry. Both standards describe general requirements to the dosimetry system: The dose measurements must be traceable to national standards......, the uncertainty of the dose measurement and the environmental influences must be known. This paper discusses how to obtain and maintain traceability and how to document measurement uncertainty. The implications of these requirements in the process control of radiation sterilization are further discussed. Known...

  17. Spore-Forming Bacteria that Resist Sterilization

    Science.gov (United States)

    LaDuc, Myron; Venkateswaran, Kasthuri

    2003-01-01

    A report presents a phenotypic and genotypic characterization of a bacterial species that has been found to be of the genus Bacillus and has been tentatively named B. odysseensis because it was isolated from surfaces of the Mars Odyssey spacecraft as part of continuing research on techniques for sterilizing spacecraft to prevent contamination of remote planets by terrestrial species. B. odysseensis is a Gram-positive, facultatively anaerobic, rod-shaped bacterium that forms round spores. The exosporium has been conjectured to play a role in the elevated resistance to sterilization. Research on the exosporium is proposed as a path toward improved means of sterilization, medical treatment, and prevention of biofouling.

  18. Radiation sterilization facility for melon fly

    International Nuclear Information System (INIS)

    Danno, A.

    1985-01-01

    The melon fly (Dacus cucurbitae Coquillett) has been observed in Amami Island since l975. Kagoshima Prefecture has had a melon fly eradication project underway since 1979. A mass-fearing facility and a radiation sterilization facility were constructed in Naze in March of l98l. In the early stages of the project, sterile insects were produced at the rate of 4 x l0/sup 6/ pupae/week. In the later stages, the activity of the project was enlarged by tenfold. The conditions for design of the radiation sterilization facility, which has been developed with a central control system for automated irradiation, are examined from an engineering standpoint

  19. Signatures of extra dimensional sterile neutrinos

    Directory of Open Access Journals (Sweden)

    Werner Rodejohann

    2014-10-01

    Full Text Available We study a large extra dimension model with active and sterile Dirac neutrinos. The sterile neutrino masses stem from compactification of an extra dimension with radius R and are chosen to have masses around eV or keV, in order to explain short-baseline anomalies or act as warm dark matter candidates. We study the effect of the sterile neutrino Kaluza–Klein tower in short-baseline oscillation experiments and in the beta spectrum as measurable by KATRIN-like experiments.

  20. Observations on female sterilization in Chile.

    Science.gov (United States)

    Menanteau-Horta, D

    1982-01-01

    Prior to 1976, voluntary female sterilization was 1 of the regular family planning services offered in Chile. After that the Ministry of Public Health declared that it could not be considered a fertility regulation activity and could thus be performed only for health reasons. Between 1971-75, there was almost a 6-fold increase in the number of sterilizations performed at the Valdivia Regional Hospital, with a rise to 2400 procedures. Such an unprecedented increase in voluntary sterilization prompted this study. The results are based on a 1976 survey of women sterilized between 1971-75 at the Valdivia Regional Hospital. Personal interviews were conducted. The number of voluntary sterilizations there during the aforementioned period showed a sustained upward trend; the number of births increased only moderately during that time. The data on sterilization in the Valdivia area is compared to that collected by the Santiago study. Age, marital status, place of origin or residence, education, and religion were compared. Socioeconomic and occupational data were also examined. 9 of 10 women in Valdivia were from low-income families. This agrees closely with the Santiago data. About 1/4 of the women in both samples were employed outside the home. Also in both samples, about 1/2 of the spouses of sterilized women were blue collar workers; only 1/5 or less were white collar, and very few were professionals. About 52% in Valdivia and 45% in Santiago had borne 7 or more viable offspring. The average number of spontaneous abortions was also similar. A significantly higher percentage (P0.01) of Valdivia women used contraceptives. There are some general trends apparent in both groups as to the reasons for sterilization; most were prompted by difficult socioeconomic conditions. 37.9% of the Santiago women felt their families were complete and 27.3% of the other group cited the same reason. Other reasons were medical, failure of contraception, problems with spouse, and other. Medical

  1. Opto-mechatronics issues in solid immersion lens based near-field recording

    Science.gov (United States)

    Park, No-Cheol; Yoon, Yong-Joong; Lee, Yong-Hyun; Kim, Joong-Gon; Kim, Wan-Chin; Choi, Hyun; Lim, Seungho; Yang, Tae-Man; Choi, Moon-Ho; Yang, Hyunseok; Rhim, Yoon-Chul; Park, Young-Pil

    2007-06-01

    We analyzed the effects of an external shock on a collision problem in a solid immersion lens (SIL) based near-field recording (NFR) through a shock response analysis and proposed a possible solution to this problem with adopting a protector and safety mode. With this proposed method the collision between SIL and media can be avoided. We showed possible solution for contamination problem in SIL based NFR through a numerical air flow analysis. We also introduced possible solid immersion lens designs to increase the fabrication and assembly tolerances of an optical head with replicated lens. Potentially, these research results could advance NFR technology for commercial product.

  2. Contact Lens Related Corneal Ulcer

    OpenAIRE

    Loh, KY; Agarwal, P

    2010-01-01

    A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are: overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. Th...

  3. A course in lens design

    CERN Document Server

    Velzel, Chris

    2014-01-01

    A Course in Lens Design is an instruction in the design of image-forming optical systems. It teaches how a satisfactory design can be obtained in a straightforward way. Theory is limited to a minimum, and used to support the practical design work. The book introduces geometrical optics, optical instruments and aberrations. It gives a description of the process of lens design and of the strategies used in this process. Half of its content is devoted to the design of sixteen types of lenses, described in detail from beginning to end. This book is different from most other books on lens design because it stresses the importance of the initial phases of the design process: (paraxial) lay-out and (thin-lens) pre-design. The argument for this change of accent is that in these phases much information can be obtained about the properties of the lens to be designed. This information can be used in later phases of the design. This makes A Course in Lens Design a useful self-study book, and a suitable basis for an intro...

  4. Gabor lens theory

    International Nuclear Information System (INIS)

    Irani, A.A.

    1978-01-01

    The principle of using the space charge of an electron cloud to focus ion beams was first proposed by Gabor. Electrons are to be confined radially by means of an axial magnetic field B/sub z/ and axially by means of externally applied electric fields E/sub z/. An ion beam of charge density n/sub i/ much less than n/sub e/, the electron charge density can then be focused by the radial electric field set up by the electron cloud. The case considered here is that of a hollow cylindrical conductor charged to a potential +V with grounded rings on either side to set up the axial E/sub z/ field. A solenoid wound around the central conductor supplies the B/sub z/ field. Theoretical calculations are carried out for n/sub e/ maximum as a function of B/sub z/ due to radial confinement and V due to axial confinement and the focal length of the Gabor Lens is calculated

  5. Factors affecting the efficiency of the sterile insect release method for tsetse

    International Nuclear Information System (INIS)

    Curtis, C.F.

    1980-01-01

    Data are reviewed on the levels of sterility, survival and competitiveness of Glossina males after irradiation with various gamma-ray doses delivered in air or nitrogen. A simple population model helps in the choice of the optimum dose. Field studies of mating competitiveness require a measure of the ratio of sterile to fertile males and of sterile to fertile matings, and both ratio estimates will be subject to sampling error. Data on multiple mating of female Glossina are reviewed. There is some degree of precedence for sperm from the first mating but sterile sperm are fully competitive for fertilization and, following the early death of an embryo, the timing of the next ovulation is only advanced to a slight extent. Thus in an isolated population the occurrence or non-occurrence of female polygamy would be of almost no consequence. Where mated females were immigrating into the release area female polygamy would be advantageous. The low recovery potential of tsetse populations is the main reason for thinking them suitable for control by the introduction of sterility. In trying to measure this recovery potential it is important to distinguish it from natural seasonal increase. If natural population fluctuations are studied to detect density dependent effects it is important not to confuse cause with effect. Non-isolation of the 'target' population is almost certainly the most serious obstacle to practical application of the sterile insect release method, and a steady 'rolling forward' of the release area may be a possible solution. (author)

  6. Radiation sterilization of animal farm sewage

    International Nuclear Information System (INIS)

    Rosiak, J.; Perkowski, J.; Pekala, W.

    1984-01-01

    Influence of irradiation on organisms appearing in farm sewage has been discussed. Practical examples of employing the radiation to sterilization of municipal wastes and liquid sewage from the industrial swine farms have been presented. (author)

  7. How to make a sterile helper.

    Science.gov (United States)

    Downing, Philip A; Cornwallis, Charlie K; Griffin, Ashleigh S

    2017-01-01

    The sterile worker castes found in the colonies of social insects are often cited as archetypal examples of altruism in nature. The challenge is to explain why losing the ability to mate has evolved as a superior strategy for transmitting genes into future generations. We propose that two conditions are necessary for the evolution of sterility: completely overlapping generations and monogamy. A review of the literature indicates that when these two conditions are met we consistently observe the evolution of sterile helpers. We explain the theory and evidence behind these ideas, and discuss the importance of ecology in predicting whether sterility will evolve using examples from social birds, mammals, and insects. In doing so, we offer an explanation for the extraordinary lifespans of some cooperative species which hint at ways in which we can unlock the secrets of long life. © 2016 WILEY Periodicals, Inc.

  8. Encapsulation process sterilizes and preserves surgical instruments

    Science.gov (United States)

    Montgomery, L. C.; Morelli, F. A.

    1964-01-01

    Ethylene oxide is blended with an organic polymer to form a sterile material for encapsulating surgical instruments. The material does not bond to metal and can be easily removed when the instruments are needed.

  9. Determination of sterilizing dose of lincocine drug

    International Nuclear Information System (INIS)

    Adawi, M.A.; Shamma, M.; Al-Mousa, A.

    1998-01-01

    There are too many antibiotics that have been studied on their dry solid state to determine their safe sterilizing dose by decreasing their bio burden in order to reach the sterility assurance level (SAL) needed. The sterilizing radiating dose of lincocine was determined according to information about their bio burden and radiating sensitivity at the sterility assurance level 10-6. The study of bio burden has shown that the contamination was fungal (Pemicillium sp.) and by applying the same tests to the raw materials of lincocine it came out that the cause of contamination was bad storage and that the radiating dose required to decrease the bio burden was 5.5 kGy. (author)

  10. Safety and efficacy of hysteroscopic sterilization compared with laparoscopic sterilization: an observational cohort study.

    Science.gov (United States)

    Mao, Jialin; Pfeifer, Samantha; Schlegel, Peter; Sedrakyan, Art

    2015-10-13

    To compare the safety and efficacy of hysteroscopic sterilization with the "Essure" device with laparoscopic sterilization in a large, all-inclusive, state cohort. Population based cohort study. Outpatient interventional setting in New York State. Women undergoing interval sterilization procedure, including hysteroscopic sterilization with Essure device and laparoscopic surgery, between 2005 and 2013. Safety events within 30 days of procedures; unintended pregnancies and reoperations within one year of procedures. Mixed model accounting for hospital clustering was used to compare 30 day and 1 year outcomes, adjusting for patient characteristics and other confounders. Time to reoperation was evaluated using frailty model for time to event analysis. We identified 8048 patients undergoing hysteroscopic sterilization and 44,278 undergoing laparoscopic sterilization between 2005 and 2013 in New York State. There was a significant increase in the use of hysteroscopic procedures during this period, while use of laparoscopic sterilization decreased. Patients undergoing hysteroscopic sterilization were older than those undergoing laparoscopic sterilization and were more likely to have a history of pelvic inflammatory disease (10.3% v 7.2%, Psterilization was not associated with a higher risk of unintended pregnancy (odds ratio 0.84 (95% CI 0.63 to 1.12)) but was associated with a substantially increased risk of reoperation (odds ratio 10.16 (7.47 to 13.81)) compared with laparoscopic sterilization. Patients undergoing hysteroscopic sterilization have a similar risk of unintended pregnancy but a more than 10-fold higher risk of undergoing reoperation compared with patients undergoing laparoscopic sterilization. Benefits and risks of both procedures should be discussed with patients for informed decisions making. © Mao et al 2015.

  11. Ethylene Oxide Gas Sterilization of Medical Devices.

    Science.gov (United States)

    Shintani, Hideharu

    2017-01-01

     Ethylene oxide gas is an agent in the sterilization of medical devices due to its effectiveness and compatibility with most materials. The advantages and disadvantages, as well as its recommended uses, are explored in this review article. The variables and their relevance on process optimization are described, the types of processing cycles are detailed and emphasis is given to the design and validation of the sterilization process.

  12. Methods of sterilization and monitoring of sterilization across selected dental practices in karachi, pakistan

    International Nuclear Information System (INIS)

    Ahmed, H.

    2015-01-01

    To assess methods of sterilization in dental practices in Karachi and secondly to investigate methods of monitoring sterilization in dental practices in Karachi, Pakistan. Study Design: Cross-sectional, descriptive study. Place and Duration of Study: Dental colleges, hospitals and private clinics of Karachi, Pakistan, from January to March 2013. Methodology: A total of 251 questionnaires were obtained. Descriptive statistics were computed and differences between groups were assessed through chi-square test using Statistical Package for the Social Sciences (SPSS) version 16.0. P-value < 0.05 was taken as statistically significant. Results: Autoclave, used by 155 (61.8%) dentists was the most common method of sterilization followed by more than one method, 65 (25.9%); dry heat, 24 (9.6%); and cold sterilization, 7 (2.8%). Majority of dentists, 126 (50.1%), never monitored sterilization and those who did monitored mostly monthly. Statistically significant difference was found amongst the three groups of dentists monitoring sterilization (p=0.09) and methods of sterilization (p < 0.01). Conclusion: Statistically significant difference was found in infection control practices of specialists, postgraduate trainees and general dentists regarding method of monitoring sterilization with majority of dentists never monitoring sterilization. (author)

  13. GRAVITATIONAL LENS MODELING WITH GENETIC ALGORITHMS AND PARTICLE SWARM OPTIMIZERS

    International Nuclear Information System (INIS)

    Rogers, Adam; Fiege, Jason D.

    2011-01-01

    Strong gravitational lensing of an extended object is described by a mapping from source to image coordinates that is nonlinear and cannot generally be inverted analytically. Determining the structure of the source intensity distribution also requires a description of the blurring effect due to a point-spread function. This initial study uses an iterative gravitational lens modeling scheme based on the semilinear method to determine the linear parameters (source intensity profile) of a strongly lensed system. Our 'matrix-free' approach avoids construction of the lens and blurring operators while retaining the least-squares formulation of the problem. The parameters of an analytical lens model are found through nonlinear optimization by an advanced genetic algorithm (GA) and particle swarm optimizer (PSO). These global optimization routines are designed to explore the parameter space thoroughly, mapping model degeneracies in detail. We develop a novel method that determines the L-curve for each solution automatically, which represents the trade-off between the image χ 2 and regularization effects, and allows an estimate of the optimally regularized solution for each lens parameter set. In the final step of the optimization procedure, the lens model with the lowest χ 2 is used while the global optimizer solves for the source intensity distribution directly. This allows us to accurately determine the number of degrees of freedom in the problem to facilitate comparison between lens models and enforce positivity on the source profile. In practice, we find that the GA conducts a more thorough search of the parameter space than the PSO.

  14. Radiation sterilization of medical devices; Radiacyjna sterylizacja sprzetu medycznego

    Energy Technology Data Exchange (ETDEWEB)

    Kaluska, I.; Stuglik, Z. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1996-12-31

    Overview of sterilization methods of medical devices has been given, with the special stress put on radiation sterilization. A typical validation program for radiation sterilization has been shown and also a comparison of European and ISO standards concerning radiation sterilization has been discussed. (author). 13 refs, 1 fig., 2 tabs.

  15. 21 CFR 880.2800 - Sterilization process indicator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Sterilization process indicator. 880.2800 Section... Monitoring Devices § 880.2800 Sterilization process indicator. (a) Biological sterilization process indicator—(1) Identification. A biological sterilization process indicator is a device intended for use by a...

  16. Voluntary sterilization in Serbia: Unmet need?

    Directory of Open Access Journals (Sweden)

    Rašević Mirjana M.

    2002-01-01

    Full Text Available Is voluntary sterilization as a birth control method accepted in Serbia? This is certainly a question that is being imposed for research, regardless of the fact that voluntary sterilization is neither accessible nor promoted. Most importantly because there is no understanding in the social nor political sphere for legalization of voluntary sterilization as a form of birth control, apart from the clear necessity for this, first, step. They are: the recognition that voluntary sterilization is an efficient and safe birth control method, respectability of basic human as well as sexual and reproductive rights, spreading of sterilization as a form of birth control among population of both developed and developing countries and an epidemic diffusion of repeated induced abortions in Serbia. Thus individual recognition of the advantages of relying on voluntary sterilization, in a non-encouraging atmosphere, certainly represents one more argument to enable couples to prevent conception by sterilization. Since it was impossible to carry out a representative research among the population of men and women who are at risk for conception, an attempt was made to obtain a reply to the set question among women who decided to induce abortion. It was done out of at least two reasons. The first being that women with induced abortion in their reproductive history were the target group for voluntary sterilization. The second reason was based on the assumption that bringing a decision on induced abortion is preceded by the reconsideration of an earlier adopted strategy regarding children, giving birth and contraception and thus its rational component is revealed more and therefore more easily measurable. The research was carried out in the University Clinic of Obstetrics and Gynecology 'Narodni front' in Belgrade from January 21st o March 1st 2002, and included 296 women. By comparing the social and demographic characteristics of the female respondents, as well as

  17. Probability of pregnancy after sterilization: a comparison of hysteroscopic versus laparoscopic sterilization.

    Science.gov (United States)

    Gariepy, Aileen M; Creinin, Mitchell D; Smith, Kenneth J; Xu, Xiao

    2014-08-01

    To compare the expected probability of pregnancy after hysteroscopic versus laparoscopic sterilization based on available data using decision analysis. We developed an evidence-based Markov model to estimate the probability of pregnancy over 10 years after three different female sterilization procedures: hysteroscopic, laparoscopic silicone rubber band application and laparoscopic bipolar coagulation. Parameter estimates for procedure success, probability of completing follow-up testing and risk of pregnancy after different sterilization procedures were obtained from published sources. In the base case analysis at all points in time after the sterilization procedure, the initial and cumulative risk of pregnancy after sterilization is higher in women opting for hysteroscopic than either laparoscopic band or bipolar sterilization. The expected pregnancy rates per 1000 women at 1 year are 57, 7 and 3 for hysteroscopic sterilization, laparoscopic silicone rubber band application and laparoscopic bipolar coagulation, respectively. At 10 years, the cumulative pregnancy rates per 1000 women are 96, 24 and 30, respectively. Sensitivity analyses suggest that the three procedures would have an equivalent pregnancy risk of approximately 80 per 1000 women at 10 years if the probability of successful laparoscopic (band or bipolar) sterilization drops below 90% and successful coil placement on first hysteroscopic attempt increases to 98% or if the probability of undergoing a hysterosalpingogram increases to 100%. Based on available data, the expected population risk of pregnancy is higher after hysteroscopic than laparoscopic sterilization. Consistent with existing contraceptive classification, future characterization of hysteroscopic sterilization should distinguish "perfect" and "typical" use failure rates. Pregnancy probability at 1 year and over 10 years is expected to be higher in women having hysteroscopic as compared to laparoscopic sterilization. Copyright © 2014

  18. Induced mutations for fasciation in lentil (Lens culinaris Med.)

    International Nuclear Information System (INIS)

    Tyagi, B.S.; Gupta, P.K.

    1992-01-01

    A mutant with fascination in the upper part of stem was isolated in lentil (Lens culinaris) following combined treatment of gamma rays and EMS (200 Gy + 0.1% EMS). During the later stages of plant growth, due to slight flattening of stem and branches at the shoot apex, the plant appeared like a cluster of closely fused branches. Unlike earlier reported fascinated mutants in lentil, which were sterile [1], these fascinated mutants were fully fertile having normal reproductive organs, and thus are being maintained in homozygous state. Pods per bunch ranged from 2–10 as against 1–3 in the control. The mutants also differed from control in chlorophyll a and b content and other quantitative characters. The segregation data suggested monogenic recessive nature of the mutation

  19. Preparation of Silver Nano-Particles and Use as a Material for Water Sterilization

    Directory of Open Access Journals (Sweden)

    Tran Hong Con

    2011-01-01

    Full Text Available High dispersed nanodimensional silver metal (nanosilver solution of concentration ranging from 40 to 400 mg/L was prepared from silver nitrate in water media with and without dispersing reagent. The reduction process was initiated by ammonium hydroxide and glucose was used as a reductive reagent. The nanosilver solution was characterized by color changing from light-yellow to yellow, brown, red-brown, brown-green, dark-green, blue, dark-blue and those were depending on silver concentration and dimension of silver metal particles. The nanosilver solution was possibly used as a direct sterilizing reagent or coating on calcinated laterite grains to create sterilizing material in bacterial removing filter. Direct sterilization ability of nanosilver solution and nanosilver coated material was investigated. The results showed that with 10 ppb nanosilver in supplied water, all bacteria will be removed within 25–30 min. 10 mm thick layer of silica gel or 20 mm of calcinated laterite coated nanosilver could remove all bacteria in water flowed though with maximum flow rate of 100 L.m2/min. Moreover, sterilizing material was nontoxic and applicable for drinking water production.

  20. Adjustable internal structure for reconstructing gradient index profile of crystalline lens.

    Science.gov (United States)

    Bahrami, Mehdi; Goncharov, Alexander V; Pierscionek, Barbara K

    2014-03-01

    Employing advanced technologies in studying the crystalline lens of the eye has improved our understanding of the refractive index gradient of the lens. Reconstructing and studying such a complex structure requires models with adaptable internal geometry that can be altered to simulate geometrical and optical changes of the lens with aging. In this Letter, we introduce an optically well-defined, geometrical structure for modeling the gradient refractive index profile of the crystalline lens with the advantage of an adjustable internal structure that is not available with existing models. The refractive index profile assigned to this rotationally symmetric geometry is calculated numerically, yet it is shown that this does not limit the model. The study provides a basis for developing lens models with sophisticated external and internal structures without the need for analytical solutions to calculate refractive index profiles.

  1. Radiation sterilization of aseptically manufactured products.

    Science.gov (United States)

    Fairand, Barry P; Fidopiastis, Niki

    2010-01-01

    This paper discusses an approach for establishing a sterilization dose for an aseptically processed product after the product is in its final packaged state, in other words, terminal sterilization. It applies to aseptic processes where the fill/finish operation is conducted in a closed system using isolator or restricted access barrier technology, that is, no human intervention. The example that is given in this paper uses gamma radiation as the sterilizing agent. Other forms of radiation such as high-energy electrons or X-rays also could serve as the sterilizing agent. The proposed approach involves irradiation of the aseptically processed product at very low doses of radiation, which is possible due to the extremely low levels of bioburden that may be present on the product following a fill/finish operation. Rather than sacrificing a large number of product units that may be required to obtain a statistically significant sampling of the product for bioburden analysis and other test purposes, the test unit is a surrogate consisting of actual pharmaceutical product that was inoculated with a highly radiation-resistant micro-organism. Selection of the microorganism was based on analysis of a library of environmental monitoring data taken from the aseptic area. Because of microbial diversity between different aseptic processing facilities, selection of the test microorganism would depend on the aseptic area under study. The approach that is discussed in this paper addresses selection and preparation of the surrogate, test of sterility of the surrogate following irradiation, determination of the radiation resistance of the test microorganism, and application of the approach to calculate a sterilization dose that is less than 10 kGy. At this low dose, it may be possible to terminally sterilize radiation-sensitive pharmaceutical products, for example, those in liquid form. Additional studies are warranted to determine the general applicability of the proposed approach.

  2. Development of a Laue lens for nuclear astrophysics

    International Nuclear Information System (INIS)

    Barriere, N.

    2008-04-01

    The Laue lenses we study focuses in the domain of 0.1-1 MeV thanks to Bragg diffraction in the volume of a large number of small crystal tiles. The focal length of a typical Laue lens system is of the order of 100 m. This requirement calls for two formation flying satellites maintaining lens and detector at the focal distance. The major breakthrough of Laue lenses is to decouple collecting area from detector area. Concentrating a signal from the large area of a Laue lens onto a small focal spot dramatically increases the signal over background ratio with respect to present technologies. Here is the reason for the long awaited leap in sensitivity. The objective of the present thesis was to improve the concept, finding viable technical solutions towards a future space mission. Two aspects of the lens development have been highlighted in this thesis: the first one is an analytical model of the lens that is used to calculate and improve the performance of a certain configuration, the second aspect concerns the search and the characterization of diffracting media of interest. The lens model developed relies on a fast semi-analytical simulation library, permitting to build several design- and optimisation-tools. For the configuration of a given lens, this code computes the resulting effective area and point spread function in a handful of seconds. The model helps finding lens configurations (mass, pack ratio of the lens rings,...) which are automatically refined to match with effective area and energy coverage constraints. These tools have been used to investigate various design aspects, such as the influence of focal length, size, mosaic spread, structure and materials of crystals, etc... The central evaluation criterion in the model is a figure of merit, based on the compactness of the focal spot and the intensity of the collected signal. The second part of this work addresses the actual search and characterization of crystals potentially interesting for Laue lenses

  3. Sterilization Performance and Material Compatibility of Sterilizer for Dental Instruments using RF Oxygen Plasma

    Science.gov (United States)

    Sakai, Yasuhiro; Liu, Zhen; Hayashi, Nobuya; Goto, Masaaki

    2015-09-01

    The sterilization performance and material compatibility of low-pressure RF plasma sterilization method for dental instruments were investigated. RF electrode used in this experiment has been optimized for sterilization of dental instruments. The vial-type biological indicator (BI) simulating tiny space of dental instrument was used for evaluation of the sterilization performance. The pressure in the stainless chamber was fixed at 60 Pa. Sterilization of BI was achieved in shortest time 40 min at 80 W, and the sterilization effect was confirmed using three BIs. Light emission spectra of oxygen plasma indicated that production of atomic oxygen and excited oxygen molecule are maximum at pressure of 20 Pa and 200 Pa, respectively. Sterilization results of BIs indicated that successful rate increases with the oxygen pressure towards 200 Pa. Therefore, the excited oxygen molecule is deduced to be a major factor of the sterilization of BI. Surface morphology of dental instruments such as diamond bar was evaluated using scanning electron microscope (SEM). The deterioration of fine crystals of diamond bar has not observed after the plasma irradiation for 120 min with RF input power was 60W and pressure was 200 Pa.

  4. Phenology, sterility and inheritance of two environment genic male sterile (EGMS) lines for hybrid rice

    NARCIS (Netherlands)

    El-Namaky, R.; Oort, van P.A.J.

    2017-01-01

    Background: There is still limited quantitative understanding of how environmental factors affect sterility of Environment-conditioned genic male sterility (EGMS) lines. A model was developed for this purpose and tested based on experimental data from Ndiaye (Senegal) in 2013-2015. For the two

  5. Enhanced biomass production of duckweeds by inoculating a plant growth-promoting bacterium, Acinetobacter calcoaceticus P23, in sterile medium and non-sterile environmental waters.

    Science.gov (United States)

    Toyama, T; Kuroda, M; Ogata, Y; Hachiya, Y; Quach, A; Tokura, K; Tanaka, Y; Mori, K; Morikawa, M; Ike, M

    2017-09-01

    Duckweed offers the promise of a co-benefit culture combining water purification with biomass production. Acinetobacter calcoaceticus P23 is a plant growth-promoting bacterium isolated from a duckweed, Lemna aequinoctialis. This study quantified its growth-promoting effect on three duckweeds (L. aoukikusa, L. minor, and Spirodela polyrhiza) in sterile Hoagland solution and evaluated its usefulness in duckweed culture under non-sterile conditions. P23 promoted growth of three duckweeds in sterile Hoagland solution at low to high nutrient concentrations (1.25-10 mg NO 3 -N/L and 0.25-2.0 mg PO 4 -P/L). It increased the biomass production of L. aequinoctialis 3.8-4.3-fold, of L. minor 2.3-3.3-fold, and of S. polyrhiza 1.4-1.5-fold after 7 days compared with noninoculated controls. P23 also increased the biomass production of L. minor 2.4-fold in pond water and 1.7-fold in secondary effluent of a sewage treatment plant under non-sterile conditions at laboratory-scale experiments. P23 rescued L. minor from growth inhibition caused by microorganisms indigenous to the pond water. The results demonstrate that the use of P23 in duckweed culture can improve the efficiency of duckweed biomass production, and a positive effect of P23 on duckweed-based wastewater treatment can be assumed.

  6. Experiences of coercion to sterilize and forced sterilization among women living with HIV in Latin America.

    Science.gov (United States)

    Kendall, Tamil; Albert, Claire

    2015-01-01

    Forced and coerced sterilization is an internationally recognized human rights violation reported by women living with HIV (WLHIV) around the globe. Forced sterilization occurs when a person is sterilized without her knowledge or informed consent. Coerced sterilization occurs when misinformation, intimidation tactics, financial incentives or access to health services or employment are used to compel individuals to accept the procedure. Drawing on community-based research with 285 WLHIV from four Latin American countries (El Salvador, Honduras, Mexico and Nicaragua), we conduct thematic qualitative analysis of reports of how and when healthcare providers pressured women to sterilize and multivariate logistic regression to assess whether social and economic characteristics and fertility history were associated with pressure to sterilize. A quarter (23%) of the participant WLHIV experienced pressure to sterilize post-diagnosis. WLHIV who had a pregnancy during which they (and their healthcare providers) knew their HIV diagnosis were almost six times more likely to experience coercive or forced sterilization than WLHIV who did not have a pregnancy with a known diagnosis (OR 5.66 CI 95% 2.35-13.58 p≤0.001). WLHIV reported that healthcare providers told them that living with HIV annulled their right to choose the number and spacing of their children and their contraceptive method, employed misinformation about the consequences of a subsequent pregnancy for women's and children's health, and denied medical services needed to prevent vertical (mother-to-child) HIV transmission to coerce women into accepting sterilization. Forced sterilization was practiced during caesarean delivery. The experiences of WLHIV indicate that HIV-related stigma and discrimination by healthcare providers is a primary driver of coercive and forced sterilization. WLHIV are particularly vulnerable when seeking maternal health services. Health worker training on HIV and reproductive rights

  7. The SNAP Strong Lens Survey

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, P.

    2005-01-03

    Basic considerations of lens detection and identification indicate that a wide field survey of the types planned for weak lensing and Type Ia SNe with SNAP are close to optimal for the optical detection of strong lenses. Such a ''piggy-back'' survey might be expected even pessimistically to provide a catalogue of a few thousand new strong lenses, with the numbers dominated by systems of faint blue galaxies lensed by foreground ellipticals. After sketching out our strategy for detecting and measuring these galaxy lenses using the SNAP images, we discuss some of the scientific applications of such a large sample of gravitational lenses: in particular we comment on the partition of information between lens structure, the source population properties and cosmology. Understanding this partitioning is key to assessing strong lens cosmography's value as a cosmological probe.

  8. Automated Fresnel lens tester system

    Energy Technology Data Exchange (ETDEWEB)

    Phipps, G.S.

    1981-07-01

    An automated data collection system controlled by a desktop computer has been developed for testing Fresnel concentrators (lenses) intended for solar energy applications. The system maps the two-dimensional irradiance pattern (image) formed in a plane parallel to the lens, whereas the lens and detector assembly track the sun. A point detector silicon diode (0.5-mm-dia active area) measures the irradiance at each point of an operator-defined rectilinear grid of data positions. Comparison with a second detector measuring solar insolation levels results in solar concentration ratios over the image plane. Summation of image plane energies allows calculation of lens efficiencies for various solar cell sizes. Various graphical plots of concentration ratio data help to visualize energy distribution patterns.

  9. Gamma radiation sterilized amnion: use in ophthalmology

    International Nuclear Information System (INIS)

    Martinez P, M. E.; Leon T, Y.; Vazquez M, L.

    2010-10-01

    Amnion processed at the Radio sterilized Tissue Bank at the National Institute of Nuclear Research, sterilized with 60 Co gamma radiation, have been used in Mexico since 2005 either as a graft to replace the damaged ocular surface, or as a patch to prevent unwanted inflammatory reactions. Patients from the Hospital General de Mexico (HGM) and Instituto Mexicano del Seguro Social (IMSS), suffering diverse pathologies such as keratoconjunctivitis; recurrent pterygium associated with symblepharon; corneal neuro trophic ulcers, chemical and thermal burns, and corneal thinning s, had been successfully treated with irradiated amnion. In the HGM, a clinical prospective study on lesions of the ocular surface of 17 eyes from 15 patients, affected with the above mentioned pathologies, was successful in 88.2%. The results have proven to be excellent as much for cosmetic purposes as for functional ones. Without the treatment, the patients could have suffered a healing after-effect or loss of sight. At IMSS, a controlled clinical randomized trial with 108 eyes from 100 patients, affected with primary nasal pterygium, was performed in 2009. These eyes were treated with radio sterilized amnion and intraoperative mitomycin C to prevent recurrence after excision of the primary pterygium. The preliminary results do not shown adverse reaction, inflammation and pain were significantly reduced radio sterilized amnion also offer security because they do no express antigens HLA-A, B or Dr and the sterile irradiated tissue do not provoke rejection or transmit an infective disease. (Author)

  10. Gamma radiation sterilized amnion: use in ophthalmology

    Energy Technology Data Exchange (ETDEWEB)

    Martinez P, M. E. [ININ, Carretera Mexico-Toluca s/n, Ocoyoacac 52750, Estado de Mexico (Mexico); Leon T, Y. [Hospital General Regional 220, IMSS, Paseo Tollocan No. 620, Col. Vertice, Toluca 50150, Estado de Mexico (Mexico); Vazquez M, L., E-mail: esther.martinez@inin.gob.m [Hospital General de Mexico, Dr. Balmis 148, Col. Doctores, 06720 Mexico D. F. (Mexico)

    2010-10-15

    Amnion processed at the Radio sterilized Tissue Bank at the National Institute of Nuclear Research, sterilized with {sup 60}Co gamma radiation, have been used in Mexico since 2005 either as a graft to replace the damaged ocular surface, or as a patch to prevent unwanted inflammatory reactions. Patients from the Hospital General de Mexico (HGM) and Instituto Mexicano del Seguro Social (IMSS), suffering diverse pathologies such as keratoconjunctivitis; recurrent pterygium associated with symblepharon; corneal neuro trophic ulcers, chemical and thermal burns, and corneal thinning s, had been successfully treated with irradiated amnion. In the HGM, a clinical prospective study on lesions of the ocular surface of 17 eyes from 15 patients, affected with the above mentioned pathologies, was successful in 88.2%. The results have proven to be excellent as much for cosmetic purposes as for functional ones. Without the treatment, the patients could have suffered a healing after-effect or loss of sight. At IMSS, a controlled clinical randomized trial with 108 eyes from 100 patients, affected with primary nasal pterygium, was performed in 2009. These eyes were treated with radio sterilized amnion and intraoperative mitomycin C to prevent recurrence after excision of the primary pterygium. The preliminary results do not shown adverse reaction, inflammation and pain were significantly reduced radio sterilized amnion also offer security because they do no express antigens HLA-A, B or Dr and the sterile irradiated tissue do not provoke rejection or transmit an infective disease. (Author)

  11. Revisiting cosmological bounds on sterile neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Vincent, Aaron C. [Institute for Particle Physics Phenomenology (IPPP), Department of Physics, Durham University, Durham DH1 3LE (United Kingdom); Martínez, Enrique Fernández [Departamento and Instituto de Física Teórica (IFT), UAM/CSIC, Universidad Autonoma de Madrid, C/ Nicolás Cabrera 13-15, E-28049 Cantoblanco, Madrid (Spain); Hernández, Pilar; Mena, Olga [Instituto de Física Corpuscular (IFIC), CSIC-Universitat de València, Apartado de Correos 22085, E-46071 Valencia (Spain); Lattanzi, Massimiliano, E-mail: aaron.vincent@durham.ac.uk, E-mail: enrique.fernandez-martinez@uam.es, E-mail: m.pilar.hernandez@uv.es, E-mail: omena@ific.uv.es, E-mail: lattanzi@fe.infn.it [Dipartimento di Fisica e Science della Terra, Università di Ferrara and INFN, sezione di Ferrara, Polo Scientifico e Tecnologico, Edificio C Via Saragat, 1, I-44122 Ferrara (Italy)

    2015-04-01

    We employ state-of-the art cosmological observables including supernova surveys and BAO information to provide constraints on the mass and mixing angle of a non-resonantly produced sterile neutrino species, showing that cosmology can effectively rule out sterile neutrinos which decay between BBN and the present day. The decoupling of an additional heavy neutrino species can modify the time dependence of the Universe's expansion between BBN and recombination and, in extreme cases, lead to an additional matter-dominated period; while this could naively lead to a younger Universe with a larger Hubble parameter, it could later be compensated by the extra radiation expected in the form of neutrinos from sterile decay. However, recombination-era observables including the Cosmic Microwave Background (CMB), the shift parameter R{sub CMB} and the sound horizon r{sub s} from Baryon Acoustic Oscillations (BAO) severely constrain this scenario. We self-consistently include the full time-evolution of the coupled sterile neutrino and standard model sectors in an MCMC, showing that if decay occurs after BBN, the sterile neutrino is essentially bounded by the constraint sin{sup 2}θ ∼< 0.026 (m{sub s}/eV){sup −2}.

  12. Sterilization and disinfection: the prevailing indifference

    International Nuclear Information System (INIS)

    Mirza, I.

    2007-01-01

    To evaluate the knowledge and attitude of health care professionals towards the process of sterilization and disinfection, and to check the adequacy of the reading material accessible to them. The study comprised of three components. In the first part, sections devoted to this subject in the popular books read by the students of operation theatre assistant course and students of diploma in general nursing were examined for adequacy and authenticity of information. In the second part, standard operating procedures were examined regarding sterilization of textile, rubber tubes of suction units and diathermy hand pieces of 20 operation theatres of three teaching hospital attached to undergraduate medical college of Punjab. In the third part of the study, working knowledge of 64 practicing operation theatre assistants and 57 practicing nurses was assessed through a questionnaire. It was found that popular books either did not contain the required information or the information provided was misleading or incorrect. Standard operating procedures for sterilization of selected items of all the operation theatres studied fell much below the standard of practice desired in the light of current knowledge and contemporary practices. Finally the working knowledge of the professionals studied was much below the bare minimum expected by the profession. There is a dire need for upgrading the knowledge and attitude of health care professionals regarding sterilization, besides improving the operation theatres sterilization procedures. (author)

  13. Contact lens disinfection by ultraviolet light

    Energy Technology Data Exchange (ETDEWEB)

    Dolman, P.J.; Dobrogowski, M.J. (Univ. of British Columbia, Vancouver (Canada))

    1989-12-15

    A 253.7-nm ultraviolet light with an intensity of 1,100 microW/cm2 was tested for its germicidal activity against contact lenses and storage solutions contaminated with various corneal pathogens. The exposure time necessary to reduce a concentration of organisms from 10(6)/ml to less than 10/ml was 30 seconds for Staphylococcus aureus, 60 seconds for Pseudomonas aeruginosa, and 84 seconds for Candida albicans. The time necessary to sterilize a suspension of 10(4)/ml Acanthamoeba polyphaga was less than three minutes with this technique. Four brands of soft contact lenses were exposed to ultraviolet light for over eight hours without changing their appearance, comfort, or refraction.

  14. Contact lens disinfection by ultraviolet light

    International Nuclear Information System (INIS)

    Dolman, P.J.; Dobrogowski, M.J.

    1989-01-01

    A 253.7-nm ultraviolet light with an intensity of 1,100 microW/cm2 was tested for its germicidal activity against contact lenses and storage solutions contaminated with various corneal pathogens. The exposure time necessary to reduce a concentration of organisms from 10(6)/ml to less than 10/ml was 30 seconds for Staphylococcus aureus, 60 seconds for Pseudomonas aeruginosa, and 84 seconds for Candida albicans. The time necessary to sterilize a suspension of 10(4)/ml Acanthamoeba polyphaga was less than three minutes with this technique. Four brands of soft contact lenses were exposed to ultraviolet light for over eight hours without changing their appearance, comfort, or refraction

  15. Computer-aided lens assembly

    Science.gov (United States)

    Tomlinson, Richard; Alcock, Rob; Petzing, Jon; Coupland, Jeremy

    2004-01-01

    We propose a computer-aided method of lens manufacture that allows assembly, adjustment, and test phases to be run concurrently until an acceptable level of optical performance is reached. Misalignment of elements within a compound lens is determined by a comparison of the results of physical ray tracing by use of an array of Gaussian laser beams with numerically obtained geometric ray traces. An estimate of misalignment errors is made, and individual elements are adjusted in an iterative manner until performance criteria are achieved. The method is illustrated for the alignment of an air-spaced doublet.

  16. Acanthamoeba keratitis. Contact lens and noncontact lens characteristics.

    Science.gov (United States)

    Chynn, E W; Lopez, M A; Pavan-Langston, D; Talamo, J H

    1995-09-01

    To identify potential differences in time to diagnosis and final visual outcome between contact lens and noncontact lens users with Acanthamoeba keratitis. Prior studies have shown early diagnosis and therapy to be related to outcome but have not analyzed differences among patients with and without contact lenses. A retrospective analysis of 11 consecutive cases (involving 13 eyes) of Acanthamoeba keratitis diagnosed at one institution over a 3-year period. Mean time to diagnosis was significantly longer in noncontact lens users versus those who wore contact lenses (mean, 5.8 versus 3.3 weeks). Fifty percent of patients who did not wear contact lenses had a poor outcome (visual acuity worse than 20/40 or penetrating keratoplasty) versus 14% of patients who wore contact lenses. Diagnoses were made later in patients without contact lenses, and these patients had a worse visual outcome than those with Acanthamoeba keratitis who wore contact lenses. All patients with unresponsive microbial keratitis, even those without contact lens use, should be evaluated for Acanthamoeba.

  17. Aero-acoustics noise assessment for Wind-Lens turbine

    International Nuclear Information System (INIS)

    Hashem, I.; Mohamed, M.H.; Hafiz, A.A.

    2017-01-01

    This paper introduces an aero-acoustic computational study that investigates the noise caused by one of the most promising wind energy conversion concepts, namely the 'Wind-Lens' technology. The hybrid method - where the flow field and acoustic field are solved separately, was deemed to be an appropriate tool to compute this study. The need to investigate this phenomenon increased gradually, since the feasibility of utilizing Wind-Lens turbine within densely populated cities and urban areas depends largely on their noise generation. Ffowcs Williams-Hawkings (FW-H) equation and its integral solution are used to predict the noise radiating to the farfield. CFD Simulations of transient three-dimensional flow field using (URANS) unsteady Reynolds-averaged Navier-Stokes equations are computed to acquire the acoustic sources location and sound intensity. Then, the noise propagates from the before-mentioned sources to pre-defined virtual microphones positioned in different locations. ANSYS-FLUENT is used to calculate the flow field on and around such turbines which is required for the FW-H code. Some effective parameters are investigated such as Wind-Lens shape, brim height and tip speed ratio. Comparison of the noise emitted from the bare wind turbine and different types of Wind-Lens turbine reveals that, the Wind-Lens generates higher noise intensity. - Highlights: • Aero-acoustic noise generated by wind turbines are one of the major challenges. • Noise from wind turbine equipped with a brimmed diffuser is investigated. • A computational aero-acoustic study using the hybrid method is introduced. • Effective parameters are studied such Wind-Lens shape, brim height and speed ratio. • The optimal shape has a moderate power coefficient and the less noise generation.

  18. Contraceptive sterilization among Canadians, 1984-1995

    Directory of Open Access Journals (Sweden)

    Vijaya Krishnan

    2004-12-01

    Full Text Available Prior to early 1970s, traditional methods were the principal means of controlling the number and spacing of births. Today, an estimated 57 per cent of the world’s married women use contraceptives and half use modern methods such as medical sterilizations. Recent statistics suggest that Canada has the highest sterilization rate in the Western world. This paper presents findings of research examining sterilization trends in Canada with respect to changing patterns in the use of modern contraceptives, using data from the 1984 Canadian Fertility Survey (CFS and the 1995 General Social Survey (GSS. The main finding is that there is a decrease in the use of tubal ligation and an increase in the use of hysterectomy over the period 1984-1995. Less educated women are more likely to be in the forefront of modern methods of contraception.

  19. Dosimetry requirements derived from the sterilization standards

    DEFF Research Database (Denmark)

    Miller, A.

    1998-01-01

    The main standards for radiation sterilization, ISO 11137 and EN 552, rest the documentation for the properly executed sterilization process on dosimetry. Both standards describe general requirements to the dosimetry system: The dose measurements must be traceable to national standards...... and documented uncertainty limits of the dose measurements can be used to specify process control limits. This is also useful, for example, when dose setting experiments are carried out according to the methods described in ISO 11137, where product samples shall be irradiated within narrow limits......., the uncertainty of the dose measurement and the environmental influences must be known. This paper discusses how to obtain and maintain traceability and how to document measurement uncertainty. The implications of these requirements in the process control of radiation sterilization are further discussed. Known...

  20. Radiation Fusion Technology for Sewage Sterilization

    Energy Technology Data Exchange (ETDEWEB)

    Lee, M. J.; Kim, T. H.; Ryu, S. H.; Jung, I. H.; Lee, O. M.; Kim, T. H. [Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of)

    2011-05-15

    Environmental regulation for effluent of sewage and wastewater treatment plant is going to be reinforced in terms of ecology toxicity and number of E.coli from 2011. Besides, it has been known that UV technology is not enough to be a sterilization tool due to regrowth of E.coli even after treatment with UV. Therefore it needs a novel technology for both restriction of E.coli regrowth and treatment of toxic materials in order to meet the environmental regulation being enforced. Electron beam has unique capabilities on destruction of chemicals and sterilization of microbial. In this study, field study on destruction of antibiotics and endocrine disruptors, reduction ecological toxicity and E.Coli regrowth was carried out using by mobile electron beam accelerator. Experimental results showed that irradiation on effluent could effectively reduce not only ecology toxicity but regrowth of E.coli by destruction of chemicals and complete sterilization

  1. [Paper on sterilization in the family planning programs of Colombia: a national debate].

    Science.gov (United States)

    Rizo, A; Roper, L

    1986-01-01

    During 1984, family planning became the object of heated public debate in Colombia. In particular, considerable controversy surrounded the practice of sterilization. In Colombia in 1980, 49% of married women were practicing family planning. The main protagonist has been Profamilia, an IPPF affliate, which runs clinics and advisory services throughout Colombia. Sterilization is performed quite extensively on men of at least 28 years and women of 25 with 3 living children. Further activities of Profamilia include community distribution and social marketing programs. Many of the health facilities used are those of the Ministry of Public Health. The Minister of Health responded to criticism levelled by the Catholic church and others by instituting an investigation into alleged practices of mass sterilization. Profamilia declared publicy that sterilization was performed only under certain conditions, after waiting periods, and under no circumstances with coersion. Various groups including medical associations publicy supported Profamilia. Although recognizing the need for families to be limited in size, religious and other commentators suggested that sterilization was often presented as a solution to family ills, and that it represented foreign involvement in Colombian social policy. The opposing opinions were that church-supported natural family planning was not an effective enough strategy. The ministry has resolved to invoke more stringent screening of women desiring sterilization to include natural family planning in its programs, and to deal with international organizations only on the ministry level. The number of sterilizations has diminished. The controversy helped to expose political weaknesses of Profamilia's programs (e.g. the use of monetary incentives; lack of supervision).

  2. Induced mutant for male sterility in niger

    International Nuclear Information System (INIS)

    Sujatha, M.

    2001-01-01

    Full text: Niger (Guizotia abyssinica Cass.), an important oilseed crop of the family Compositae is highly cross-pollinated due to the twin mechanisms of protandry and incompatibility. Studies revealed the functional nature of protandry and the breakdown of incompatibility with alteration in temperature. It has very small flowers (disc florets) arranged in a capitulum that open on 3-4 consecutive days which pose problems in emasculation for cross-breeding. To induce mutations, seeds of variety 'IGP-76' were irradiated with γ-rays 200 to 1000 Gy. All seeds of M 1 plants were sown separately in individual plant-to progeny rows. The results of screening of M 2 segregating material indicated that γ-ray treatment was effective in induction of male sterility. Frequency of visible mutations were higher in sibbed progeny as compared to open pollinated population and male sterile plants were observed only in sibbed population (1000 Gy). Male sterile plants could easily be identified at the flowering stage by their altered floral morphology (disc florets transformed into ligulate ray florets) and complete absence or presence of a rudimentary anther column. Seeds were collected following sib-mating with the fertile counterparts. Progeny segregated in a ration of 3 normal : 1 male sterile. Further work on the mechanism of sterility, maintenance and linkage relationships with associated characters is under progress. This is the first report of induction of male sterility in niger through the use of physical mutagens. The availability of this mutant will be of great value for exploitation of heterosis on commercial basis. (author)

  3. About the Sterilization of Chitosan Hydrogel Nanoparticles.

    Directory of Open Access Journals (Sweden)

    Raquel Galante

    Full Text Available In the last years, nanostructured biomaterials have raised a great interest as platforms for delivery of drugs, genes, imaging agents and for tissue engineering applications. In particular, hydrogel nanoparticles (HNP associate the distinctive features of hydrogels (high water uptake capacity, biocompatibility with the advantages of being possible to tailor its physicochemical properties at nano-scale to increase solubility, immunocompatibility and cellular uptake. In order to be safe, HNP for biomedical applications, such as injectable or ophthalmic formulations, must be sterile. Literature is very scarce with respect to sterilization effects on nanostructured systems, and even more in what concerns HNP. This work aims to evaluate the effect and effectiveness of different sterilization methods on chitosan (CS hydrogel nanoparticles. In addition to conventional methods (steam autoclave and gamma irradiation, a recent ozone-based method of sterilization was also tested. A model chitosan-tripolyphosphate (TPP hydrogel nanoparticles (CS-HNP, with a broad spectrum of possible applications was produced and sterilized in the absence and in the presence of protective sugars (glucose and mannitol. Properties like size, zeta potential, absorbance, morphology, chemical structure and cytotoxicity were evaluated. It was found that the CS-HNP degrade by autoclaving and that sugars have no protective effect. Concerning gamma irradiation, the formation of agglomerates was observed, compromising the suspension stability. However, the nanoparticles resistance increases considerably in the presence of the sugars. Ozone sterilization did not lead to significant physical adverse effects, however, slight toxicity signs were observed, contrarily to gamma irradiation where no detectable changes on cells were found. Ozonation in the presence of sugars avoided cytotoxicity. Nevertheless, some chemical alterations were observed in the nanoparticles.

  4. About the Sterilization of Chitosan Hydrogel Nanoparticles.

    Science.gov (United States)

    Galante, Raquel; Rediguieri, Carolina F; Kikuchi, Irene Satiko; Vasquez, Pablo A S; Colaço, Rogério; Serro, Ana Paula; Pinto, Terezinha J A

    2016-01-01

    In the last years, nanostructured biomaterials have raised a great interest as platforms for delivery of drugs, genes, imaging agents and for tissue engineering applications. In particular, hydrogel nanoparticles (HNP) associate the distinctive features of hydrogels (high water uptake capacity, biocompatibility) with the advantages of being possible to tailor its physicochemical properties at nano-scale to increase solubility, immunocompatibility and cellular uptake. In order to be safe, HNP for biomedical applications, such as injectable or ophthalmic formulations, must be sterile. Literature is very scarce with respect to sterilization effects on nanostructured systems, and even more in what concerns HNP. This work aims to evaluate the effect and effectiveness of different sterilization methods on chitosan (CS) hydrogel nanoparticles. In addition to conventional methods (steam autoclave and gamma irradiation), a recent ozone-based method of sterilization was also tested. A model chitosan-tripolyphosphate (TPP) hydrogel nanoparticles (CS-HNP), with a broad spectrum of possible applications was produced and sterilized in the absence and in the presence of protective sugars (glucose and mannitol). Properties like size, zeta potential, absorbance, morphology, chemical structure and cytotoxicity were evaluated. It was found that the CS-HNP degrade by autoclaving and that sugars have no protective effect. Concerning gamma irradiation, the formation of agglomerates was observed, compromising the suspension stability. However, the nanoparticles resistance increases considerably in the presence of the sugars. Ozone sterilization did not lead to significant physical adverse effects, however, slight toxicity signs were observed, contrarily to gamma irradiation where no detectable changes on cells were found. Ozonation in the presence of sugars avoided cytotoxicity. Nevertheless, some chemical alterations were observed in the nanoparticles.

  5. Treatment, material, care, and patient-related factors in contact lens-related dry eye.

    Science.gov (United States)

    Ramamoorthy, Padmapriya; Sinnott, Loraine T; Nichols, Jason J

    2008-08-01

    To examine the effect of general contact lens and material characteristics, care solutions, treatment, and patient-related factors on contact lens-related dry eye. The data were derived from the Contact Lens and Dry Eye Study, designed as a cross-sectional and nested case-control study including 360 subjects. In separate statistical models, logistic regression was used to examine general contact lens characteristics, specific hydrogel lens materials, care solutions, and patient-related factors associated with dry eye status (controlled for age, gender, and current treatments). Several factors were significantly associated with dry eye, including treatment factors such as a recent contact lens refitting (odds ratios [OR] = 5.75, 95% confidence intervals [CI] = 2.14 to 15.46) and use of artificial tears/rewetting drops (OR = 1.09, 95% CI = 1.02 to 1.16), in addition, currently worn materials including Food and Drug Administration (FDA) group II (OR = 2.98, 95% CI = 1.14 to 6.19) and IV (OR = 1.87, 95% CI = 1.08 to 3.24). Significant patient-related factors included decreased overall satisfaction (OR = 3.57, 95% CI = 2.08 to 5.88,), dry eye in the absence of contact lens wear (OR = 6.54, 95% CI = 2.57 to 16.62), reduced daily lens wear duration (OR = 1.16, 95% CI = 1.06 to 1.26), and reduced ability to wear lenses as long as desired (OR = 2.44, 95% CI = 1.30 to 4.54). Care solutions were not associated with contact lens-related dry eye. The strong association of common treatment factors with dry eye status in contact lens wearers suggests that these treatments are not entirely effective. The use of high water content materials was strongly related to dry eye in lens wearers, whereas care solutions were not. Contact lens-related dry eye was also associated with several patient-related factors such as greater ocular discomfort (without lenses), dissatisfaction, and inability to wear lenses for desired durations.

  6. A microcapillary lens for X-rays

    CERN Document Server

    Dudchik, Y I

    1999-01-01

    A new design of a compound refractive lens for X-rays is proposed. The lens is made as a set of glue microlenses placed in a glass capillary. The technique of lens fabrication is described. Results of ray tracing calculations for 8 and 15 keV photons are represented.

  7. SOX. Search for sterile neutrinos with Borexino

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Mikko [Institut fuer Experimentalphysik, Universitaet Hamburg (Germany); Collaboration: BOREXINO-Collaboration

    2016-07-01

    Several observed anomalies in the neutrino sector could be explained by a 4th (sterile) neutrino with a squared mass difference in the order of 1 eV{sup 2} to the other three standard neutrinos. This hypothesis can be tested with an artificial kCi antineutrino (Ce-144/Pr-144) source deployed near or inside a large low background detector like Borexino. The SOX project (short baseline neutrino oscillation with Borexino) aims for the detection of sterile neutrinos and offers the almost unique possibility to observe the characteristic antineutrino oscillation pattern within the detector. The talk summarizes this concept and shows the sensitivities for the possible phases of the experiment.

  8. Solar neutrino detectors as sterile neutrino hunters

    Science.gov (United States)

    Pallavicini, Marco; Borexino-SOX Collaboration; Agostini, M.; Altenmüller, K.; Appel, S.; Atroshchenko, V.; Bellini, G.; Benziger, J.; Berton, N.; Bick, D.; Bonfini, G.; Bravo, D.; Caccianiga, B.; Calaprice, F.; Caminata, A.; Carlini, M.; Cavalcante, P.; Chepurnov, A.; Choi, K.; Cloué, O.; Cribier, M.; D'Angelo, D.; Davini, S.; Derbin, A.; Di Noto, L.; Drachnev, I.; Durero, M.; Etenko, A.; Farinon, S.; Fischer, V.; Fomenko, K.; Franco, D.; Gabriele, F.; Gaffiot, J.; Galbiati, C.; Gschwender, M.; Ghiano, C.; Giammarchi, M.; Goeger-Neff, M.; Goretti, A.; Gromov, M.; Hagner, C.; Houdy, Th.; Hungerford, E.; Ianni, Aldo; Ianni, Andrea; Jany, A.; Jedrzejczak, K.; Jeschke, D.; Jonquères, N.; Kobychev, V.; Korablev, D.; Korga, G.; Kornoukhov, V.; Kryn, D.; Lachenmaier, T.; Lasserre, T.; Laubenstein, M.; Lehnert, B.; Link, J.; Litvinovich, E.; Lombardi, F.; Lombardi, P.; Ludhova, L.; Lukyanchenko, G.; Machulin, I.; Manecki, S.; Maneschg, W.; Marcocci, S.; Maricic, J.; Mention, G.; Meroni, E.; Meyer, M.; Miramonti, L.; Misiaszek, M.; Montuschi, M.; Mosteiro, P.; Muratova, V.; Musenich, R.; Neumair, B.; Oberauer, L.; Ortica, F.; Papp, L.; Pocar, A.; Ranucci, G.; Razeto, A.; Re, A.; Reinert, Y.; Romani, A.; Roncin, R.; Rossi, N.; Schönert, S.; Scola, L.; Semenov, D.; Skorokhvatov, M.; Smirnov, O.; Sotnikov, A.; Suvorov, Y.; Tartaglia, R.; Testera, G.; Thurn, J.; Toropova, M.; Unzhakov, E.; Veyssière, C.; Vishneva, A.; Vivier, M.; Vogelaar, R. B.; von Feilitzsch, F.; Wang, H.; Weinz, S.; Winter, J.; Wojcik, M.; Wurm, M.; Yokley, Z.; Zaimidoroga, O.; Zavatarelli, S.; Zuber, K.; Zuzel, G.

    2017-09-01

    The large size and the very low radioactive background of solar neutrino detectors such as Borexino at the Gran Sasso Laboratory in Italy offer a unique opportunity to probe the existence of neutrino oscillations into new sterile components by means of carefully designed and well calibrated anti-neutrino and neutrino artificial sources. In this paper we briefly summarise the key elements of the SOX experiment, a program for the search of sterile neutrinos (and other short distance effects) by means of a 144Ce-144Pr anti-neutrino source and, possibly in the medium term future, with a 51Cr neutrino source.

  9. Validation of the sterilization process for radiopharmaceuticals and materials with humid heat

    International Nuclear Information System (INIS)

    Robles, Anita; Moore, Mariel; Morote, Mario; Guevara, Buenaventura; Castro, Delcy; Paragulla, Wilson; Martinez, Ramos; Ocana, Elias; Novoa, Carlos

    2014-01-01

    A validation protocol has been designed and applied for the sterilization process of radiopharmaceuticals and materials, with humid heat for sodium pertechnetate Tc-99m injection solution (placebo) and materials, in compliance with good manufacturing practices for pharmaceutical products. The sterilization cycle set for each load is developed, according to the following parameters: 121 o C ± 1 o C (temperature), 15 ± 0.5 psi (pressure) and an exposure time of 20 and 15 minutes, respectively. The results in the penetration test with load, F0 values were higher than 20 minutes at 121 o C and for the biological challenge by biological indicators (Bacillus stearothermophilus) was negative in colder spots, in three consecutive runs. The sterilization process for each load and equipment has been validated to meet the established acceptance criteria. (authors).

  10. A comparative study of the corrosion of wire used in urological treatment under sterilization

    Directory of Open Access Journals (Sweden)

    W. Walke

    2012-04-01

    Full Text Available The purpose of the tests was to determine whether and how sterilization process of samples made of AISI 316L stainless steel with different strain impacts their corrosion resistance. Tests were made on steel samples that had been electrochemically polished in order to assure proper surface roughness. In order to evaluate the influence of sterilization on physical and chemical properties of steel surface, tests of corrosion resistance were made by means of potentiodynamical method. The tests were made in alternative solution simulating human urine. Recorded anodic polarization curves created the ground for determination of typical parameters describing pitting corrosion resistance, that enabled to evaluate steel wire corrosion behavior under sterilization conditions.

  11. Dynamic sterilization of titanium implants with ultraviolet light

    International Nuclear Information System (INIS)

    Singh, S.; Schaaf, N.G.

    1989-01-01

    All implantable devices must be sterile. However, autoclaves produce poor surface properties that jeopardize the integration process. The application of a modified ultraviolet light source has proven to enhance bioreactivity by controlling surface properties, but it lacks validation of its sterilization capabilities. Forty-eight titanium implants were contaminated with spores of the biological indicator Bacillus stearothermophilus and subjected to dynamic sterilization by ultraviolet light. Forty-seven of the implants were successfully sterilized, as indicated by not producing turbidity in a suitable growth medium. This sterilization technique only requires a 20-second exposure to achieve sterility

  12. Research of tare hydrodynamic behaviour at sterilization of canned fish

    Directory of Open Access Journals (Sweden)

    Alexeev G. V.

    2016-09-01

    Full Text Available The paper is devoted to research on improving the equipment that ensures the absolute safety of mineral nutrients in the production of sterilized canned fish. The results of experimental study of hydrodynamic characteristics moving sterilized jars of canned fish of different sizes under the influence of circulating gas-liquid heat-carrying medium in the capacity have been presented. Some experimental setup with organized top-down and bottom-up flows in it modeling a sterilizer (autoclave has been proposed for the research. The experiments have been performed in the superficial gas velocity ranging from 0.03 m/s to 0.15 m/s corresponding to stable operation of the apparatus. Cans drag coefficient in the flow of heat-carrying medium has been determined by two methods for two heat-carrying media – pure glycerol and water solutions in experiments on precipitation and air – cans when blowing in the wind tunnel. The significant difference in the rates of cans upstream and downstream is reliably established, and therefore it has been proposed to use for the cans' motion characterization the indicator averaged over the two specified rates and called cans circulation speed. An empirical equation describing the dependence of the cans circulation rate from the superficial gas velocity has been obtained. Based on the analysis of studies some empirical dependencies on calculation of the drag coefficients of various types of packaging in the range of Reynolds criterion values from 1 to 4 000 have been offered. The necessity of using the qualifying factor for calculating the real drag on the results of the experiment has been determined.

  13. The Ultrawideband Leaky Lens Antenna

    NARCIS (Netherlands)

    Bruni, S.; Neto, A.; Marliani, F.

    2007-01-01

    A novel directive and nondispersive antenna is presented: the ultrawideband (UWB) leaky lens. It is based on the broad band Cherenkov radiation occurring at a slot printed between different infinite homogeneous dielectrics. The first part of the paper presents the antenna concept and the UWB design.

  14. ECTOPIC LENS EXTRACTION IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Vladimir Pfeifer

    2002-12-01

    Full Text Available Background. Ectopia lentis continues to be a therapeutic challenge for ophthalmologists. It can occur as an isolated condition, after ocular trauma, in association with other ocular disorders, as part of a systemic mesodermal disease or a complication of general metabolic disorders. Minimal subluxation of the lens may cause no visual symptoms, but in more advanced cases serious optical disturbances arise. The most important is amblyopia. Surgical treatment options include iris manipulation, lens discission, aspiration, intracapsular or extracapsular extraction, and pars plana lensectomy. The choice of surgical technique remains controversial, in part because of the historically poor visual results and high rate of perioperative complications, including vitreous loss and retinal detachment.Methods. We describe a surgical technique based on the use of the Cionni endocapsular tension ring, dry irrigation aspiration of lens material, centration of the capsular bag and foldable intraocular lens implantation into the bag. With mentioned surgical technique 8 patients were operated; 4 boys and 4 girls, together 11 eyes.Results. The final BCVA after follow up period improved in 9 eyes and it remained the same as before operation in one eye. Statistical comparison of preoperative and postoperative visual acuities showed significant improvement. On the other hand there was no correlation between preoperative and postoperative visual acuity.Conclusions. This surgical procedure is an alternative approach in solving this challenging cases of ectopia lentis with good postoperative visual rehabilitation.

  15. Spinning pipe gas lens revisited

    CSIR Research Space (South Africa)

    Mafusire, C

    2008-01-01

    Full Text Available , there is little information on optical phase aberrations and no study to date on the propagation parameters of the laser beam, but has rather remained rooted in the domain of ray optics. Researchers revisit the spinning pipe gas lens in this paper with new...

  16. Choice of the irradiation dose for the sterilization of medical products

    International Nuclear Information System (INIS)

    Bochkarev, V.V.; Pavlov, E.P.; Sedov, V.V.; Khrushchev, V.G.; Tushov, Eh.G.; Konyaev, G.A.

    1975-01-01

    The principles for selecting the appropriate dose for the radiation sterilization of medical products are set forth, taking into account the initial contamination of the product, the radiation senstivity of contaminants and the required level of reliability of sterilization. The initial contamination level of certain preparations (glucose and radiopharmaceuticals) is established and the radiation sensitivity of the isolated contaminants is determined in terms of Dio indices. Of the microorganisms isolated the most common were staphylococci, streptococci, Gram-negative bacteria, Aspergilli, Penicillia and yeast fungi. Spore-forming types of microorganisms were isolated with a frequency of the order of 10 -2 . The radiation sensitivity in terms of D 10 was established for more than 3000 strains of microorganisms. For 75-85% of the strains the D 10 indices gave 10-40 krad and for 0.2-1% more than 100 krad. The experimental data were subjected to computer analysis which confirmed the adequacy of the techniques used to determine radiosensitivity. The authors then calculated by computer the radiation sterilizing doses for different degrees of initial contamination of the products with reliability coefficients of 10 6 and 10 8 . For sterilizing radiopharmaceuticals and glucose solutions these doses are 0.8-1 Mrad. Verification experiments show that these doses give reliable sterilization of the medical products concerned. (author)

  17. The overall phase shift and lens effect calculation using Gaussian ...

    Indian Academy of Sciences (India)

    The solution was then used to derive expressions for the overall phase shift, focal length of the thermal lens and the end effect induced curvature of the end face. The expressions were then applied to Nd:YAG laser medium. The result shows a meaningful correction of the order of 0.001 cm to the focal length of Nd:YAG rod ...

  18. Lens stem cells may reside outside the lens capsule: an hypothesis

    Directory of Open Access Journals (Sweden)

    Meyer Rita A

    2007-06-01

    Full Text Available Abstract In this paper, we consider the ocular lens in the context of contemporary developments in biological ideas. We attempt to reconcile lens biology with stem cell concepts and a dearth of lens tumors. Historically, the lens has been viewed as a closed system, in which cells at the periphery of the lens epithelium differentiate into fiber cells. Theoretical considerations led us to question whether the intracapsular lens is indeed self-contained. Since stem cells generate tumors and the lens does not naturally develop tumors, we reasoned that lens stem cells may not be present within the capsule. We hypothesize that lens stem cells reside outside the lens capsule, in the nearby ciliary body. Our ideas challenge the existing lens biology paradigm. We begin our discussion with lens background information, in order to describe our lens stem cell hypothesis in the context of published data. Then we present the ciliary body as a possible source for lens stem cells, and conclude by comparing the ocular lens with the corneal epithelium.

  19. Planar anisotropic Mikaelian lens on the basis of EBG-structure

    Science.gov (United States)

    Kaloshin, V. A.

    2016-09-01

    The problem on the synthesis of a planar Mikaelian lens in the form of layered metal-dielectric waveguide with a nonuniform anisotropic dielectric layer is solved. The problem is reduced to solution of the dispersion equations for E and H modes of a homogeneous layered waveguide. As an example of implementation of the solution obtained, the synthesis and analysis of the Mikaelian lens is carried out on the basis of the EBG structure in the form of a planar corrugated open and closed layered metal-dielectric waveguide. For a special case of the closed waveguide, the solution of the problem of synthesis for both polarizations is obtained explicitly.

  20. Modern lens antennas for communications engineering

    CERN Document Server

    Thornton, John

    2012-01-01

    The aim of this book is to present the modern design principles and analysis of lens antennas. It gives graduates and RF/Microwave professionals the design insights in order to make full use of lens antennas.  Why do we want to write a book in lens antennas? Because this topic has not been thoroughly publicized, its importance is underestimated. As antennas play a key role in communication systems, recent development in wireless communications would indeed benefit from the characteristics of lens antennas: low profile, and low cost etc.  The major advantages of lens antennas are na

  1. Corneal cell adhesion to contact lens hydrogel materials enhanced via tear film protein deposition.

    Directory of Open Access Journals (Sweden)

    Claire M Elkins

    Full Text Available Tear film protein deposition on contact lens hydrogels has been well characterized from the perspective of bacterial adhesion and viability. However, the effect of protein deposition on lens interactions with the corneal epithelium remains largely unexplored. The current study employs a live cell rheometer to quantify human corneal epithelial cell adhesion to soft contact lenses fouled with the tear film protein lysozyme. PureVision balafilcon A and AirOptix lotrafilcon B lenses were soaked for five days in either phosphate buffered saline (PBS, borate buffered saline (BBS, or Sensitive Eyes Plus Saline Solution (Sensitive Eyes, either pure or in the presence of lysozyme. Treated contact lenses were then contacted to a live monolayer of corneal epithelial cells for two hours, after which the contact lens was sheared laterally. The apparent cell monolayer relaxation modulus was then used to quantify the extent of cell adhesion to the contact lens surface. For both lens types, lysozyme increased corneal cell adhesion to the contact lens, with the apparent cell monolayer relaxation modulus increasing up to an order of magnitude in the presence of protein. The magnitude of this increase depended on the identity of the soaking solution: lenses soaked in borate-buffered solutions (BBS, Sensitive Eyes exhibited a much greater increase in cell attachment upon protein addition than those soaked in PBS. Significantly, all measurements were conducted while subjecting the cells to moderate surface pressures and shear rates, similar to those experienced by corneal cells in vivo.

  2. Coordinated research project on radiation sterilization and decontamination of pharmaceuticals and pharmaceutical raw materials. CRP report

    International Nuclear Information System (INIS)

    2005-01-01

    processing to be carried out at any desired temperature, sterilizability of mixed products in kits, offering simultaneous sterilization and modification of polymer based formulations. Radiation sterilization has already demonstrated its advantages over conventional (chemical) methods, with the scale of its application rising. The results of the CRP demonstrated new fields of applications and roles of the process in the decontamination of natural medical herbs, which finds increasing usage worldwide. The process application for synthetic pharmaceuticals sterilization has also been demonstrated. The analytical and processing procedures were elaborated for selected materials. The radiation effects on drugs of different types and on traditional herbal medicine components (e.g.Traditional Chinese Medicines) were investigated, in particular the identification of the products of radiolysis was achieved and evaluation of their role in changing of biological activity of radiation sterilized pharmaceuticals was performed. Some of the methods were introduced to the manufacturer practice. New TC projects in the field were initiated. Despite all these apparent advantages, radiation sterilization of pharmaceuticals has to be addressed on a case by case basis. It has been concluded that radiation sterilization of aqueous solutions and suspensions of most organic substances is difficult if not impossible. The trends and opportunities of using radiation processing for sterilization and decontamination of pharmaceutical raw materials and herbs have been evaluated. Proteins and polysaccharides and their formulations and new biotechnology products are currently being considered for radiation sterilization

  3. PRINCIPLES OF HEAT STERILIZATION IN DENTAL PRACTICE

    African Journals Online (AJOL)

    preferable since they have an automatic timer for the working cycle and because they are equipped with handy containers for instruments. The pressure cooker ... Therefore dry heat sterilizers should have a time lock on the door to prevent misuse. The shelves inside must be perforated and instruments should not be tightly ...

  4. Whey powder sterilization by ionizing irradiation

    International Nuclear Information System (INIS)

    Todorovic, M.; Salatic, Z.; Markov, S.

    1988-01-01

    Whey powder was sterilized by gamma waves application. As a source of irridiation isotope 60Co was used in Institute of Nuclear sciences B oris Kidrich , Vincha-Belgrade (Yugoslavia). The applied doses were: a, b, c, d, and e Kgy. The dose d was radappertization. After whey powder irradiation no adverse changes of organoleptic properties were noticed

  5. Light sterile neutrinos: Status and perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Giunti, Carlo

    2016-07-15

    The indications in favor of the existence of light sterile neutrinos at the eV scale found in short-baseline neutrino oscillation experiments is reviewed. The future perspectives of short-baseline neutrino oscillation experiments and the connections with β-decay measurements of the neutrino masses and with neutrinoless double-β decay experiments are discussed.

  6. Detecting sterile neutrinos with KATRIN like experiments

    DEFF Research Database (Denmark)

    Riis, Anna Sejersen; Hannestad, Steen

    2011-01-01

    A sterile neutrino with mass in the eV range, mixing with bar nue, is allowed and possibly even preferred by cosmology and oscillation experiments. If such eV-mass neutrinos exist they provide a much better target for direct detection in beta decay experiments than the active neutrinos which...

  7. 21 CFR 610.12 - Sterility.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Sterility. 610.12 Section 610.12 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) BIOLOGICS GENERAL... of the organisms and ensure freedom from contamination and deterioration. If the test organisms are...

  8. Gamma radiation sterilization of Bactrocera invadens (Diptera ...

    African Journals Online (AJOL)

    The African invader fly, Bactrocera invadens, an invasive pest in Africa since 2003, causes damage and poses a threat to the mango and horticultural industry. Its control is therefore needed. Sterilization of males using gamma radiation doses (25, 50 and 75 Gy) as a means of population control was investigated. Irradiation ...

  9. STERILIZATION AND DISINFECTION IN A PRIVATE CLINIC

    African Journals Online (AJOL)

    Oral examination is done with a mirror and probe. The mirror is then washed under the tap water and disinfected in 'V3 sterilizing' fluid concentrate. The probe is placed in a tray with ... Protective glasses are worn additionally to the gloves and facemask, when cavity preparation. is being performed. The handpiece is wiped.

  10. Methods of medical sterilization; Metody sterylizacji medycznej

    Energy Technology Data Exchange (ETDEWEB)

    Stachowicz, W. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1997-10-01

    Broad review of different (physical, chemical and mechanical) methods commonly used for medical materials sterilization have been performed. Among them the special attention have been played on radiosterilization. The advantages and weaknesses each of the presented method have been pointed out. 1 fig.

  11. Sterilization of heparinized cuprophan hemodialysis membranes

    NARCIS (Netherlands)

    ten Hoopen, Hermina W.M.; Hinrichs, W.L.J.; Hinrichs, W.L.J.; Engbers, G.H.M.; Feijen, Jan

    1996-01-01

    The effects of sterilization of dry heparinized Cuprophan hemodialysis membranes by means of ethylene oxide (EtO) exposure, gamma irradiation, or steam on the anticoagulant activity and chemical characteristics of immobilized heparin and the permeability of the membrane were investigated.

  12. Sterilization: A Conference and a Report.

    Science.gov (United States)

    Dillingham, Brint

    1978-01-01

    This article continues a series on Native American sterilization, based on a conference of the National Council of Churches' Interreligious Foundation for Community Organization (IFCO). Also included are an article and a report by the American Civil Liberties Union. (Author/RTS)

  13. Steam sterilization of air turbine dental handpieces.

    Science.gov (United States)

    Edwardsson, S; Svensäter, G; Birkhed, D

    1983-12-01

    The efficacy of autoclaving high-speed dental handpieces was tested in two types of downward displacement steam sterilizers (instrument autoclaves), commonly used in the dentist's office. Eight series of experiments were performed with various sterilization schedules. Lubrication oils with or without antimicrobial agent were used in four of the series. Each handpiece was inoculated with 1 ml of a suspension containing equal amounts of saliva and spores of Bacillus stearothermophilus (approx. 10(6) spores/ml). Neither sterilization at 120-124 degrees C for 20 min nor at 134-136 degrees C for 10 min resulted in complete inactivation of the spores in series in which the instruments were tested without oil or with oil containing no antimicrobial agent. However, when the handpieces were lubricated with oil containing isopropanol and formaldehyde and the schedule 134-136 degrees C/10 min was used, no growth was observed. The results indicate that instrument autoclaves with built-in programs of 120-124 degrees C/20 min and 134-136 degrees C/10 min could have insufficient capacity to sterilize lubricated or unlubricated dental handpieces. The use of oils containing an antimicrobial agent can overcome this problem.

  14. Utilization of male sterility in forage crops

    International Nuclear Information System (INIS)

    Suginobu, Ken-ichi

    1982-01-01

    The genetic nature of male sterility in forage crops was reviewed. Many workers have suggested that hybrids in forage crops are quite promising. First, the selection of the most desirable parental genotype from a large original population is improtant in heterosis breeding programs. After the more promising inbreds or clones have been selected on the basis of good general combining ability, it is necessary to identify the particular single, three-way or double cross that will produce the highest yields. A high seed yield potential is also important in a new variety so that the seeds can be sold at lower prices than other varieties. A tentative scheme for hybrid seed production by using inbred lines of male sterile or normal parents is proposed. At a breeding station, the seeds for male sterile F 1 (AB), maintainer S 1 (C-S 1 ) and either maintainer or restorer S 1 s(D-S 1 , E-S 1 ) are produced from the parental clones. At a seed increase agency, the seeds for male sterile F 1 (ABC) and either maintainer or restorer S 2 (D-S 2 ) are produced. In the case that D-S 2 seed production is difficult, maintainer or restorer F 1 (DE) should be produced from D-S 1 x E-S 1 . These seeds are used for commercial seed production. Seeds of hybrid F 1 (ABCD) or hybrid F 1 (ABCDE) are for practical use. (Kaihara, S.)

  15. PRINCIPLES OF HEAT STERILIZATION IN DENTAL PRACTICE

    African Journals Online (AJOL)

    rust carbon steel instruments and after the work cycle is ended instruments are dry and immediately available for use. Besides the disadvantage of chemical odour in a poorly ventilated room its major drawback is its dependence on a continuous supply of the chemical agent. Dry heat sterilization. This method has the lowest ...

  16. Cosmic microwave background constraints on secret interactions among sterile neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Forastieri, Francesco; Natoli, Paolo [Dipartimento di Fisica e Scienze della Terra, Università di Ferrara, Via Giuseppe Saragat 1, I-44122 Ferrara (Italy); Lattanzi, Massimiliano [Istituto Nazionale di Fisica Nucleare, Sezione di Ferrara, Via Giuseppe Saragat 1, I-44122 Ferrara (Italy); Mangano, Gianpiero [Istituto Nazionale di Fisica Nucleare, Sezione di Napoli, Complesso Univ. Monte S.Angelo, I-80126 Napoli (Italy); Mirizzi, Alessandro [Dipartimento Interateneo di Fisica ' Michelangelo Merlin,' Via Amendola 173, 70126 Bari (Italy); Saviano, Ninetta, E-mail: francesco.forastieri@unife.it, E-mail: lattanzi@fe.infn.it, E-mail: mangano@na.infn.it, E-mail: alessandro.mirizzi@ba.infn.it, E-mail: natoli@fe.infn.it, E-mail: nsaviano@uni-mainz.de [PRISMA Cluster of Excellence and Mainz Institute for Theoretical Physics, JohannesGutenberg-Universität Mainz, 55099 Mainz (Germany)

    2017-07-01

    Secret contact interactions among eV sterile neutrinos, mediated by a massive gauge boson X (with M {sub X} || M {sub W} ), and characterized by a gauge coupling g {sub X} , have been proposed as a mean to reconcile cosmological observations and short-baseline laboratory anomalies. We constrain this scenario using the latest Planck data on Cosmic Microwave Background anisotropies, and measurements of baryon acoustic oscillations (BAO). We consistently include the effect of secret interactions on cosmological perturbations, namely the increased density and pressure fluctuations in the neutrino fluid, and still find a severe tension between the secret interaction framework and cosmology. In fact, taking into account neutrino scattering via secret interactions, we derive our own mass bound on sterile neutrinos and find (at 95 % CL) m {sub s} < 0.82 eV or m {sub s} < 0.29 eV from Planck alone or in combination with BAO, respectively. These limits confirm the discrepancy with the laboratory anomalies. Moreover, we constrain, in the limit of contact interaction, the effective strength G {sub X} to be < 2.8 (2.0) × 10{sup 10} G {sub F} from Planck (Planck+BAO). This result, together with the mass bound, strongly disfavours the region with M {sub X} ∼ 0.1 MeV and relatively large coupling g {sub X} {sub ∼} 10{sup −1}, previously indicated as a possible solution to the small scale dark matter problem.

  17. Contact lens surface by electron beam

    International Nuclear Information System (INIS)

    Shin, Jung Hyuck; Lee, Suk Ju; Hwang, Kwang Ha; Jeon Jin

    2011-01-01

    Contact lens materials needs good biocompatibility, high refractive index, high optical transparency, high water content etc. Surface treat method by using plasma and radiation can modify the physical and/or chemical properties of the contact lens surface. Radiation technology such as electron beam irradiation can apply to polymerization reaction and enhance the functionality of the polymer.The purpose of this study is to modify of contact lens surface by using Eb irradiation technology. Electron beam was irradiated to the contact lens surface which was synthesized thermal polymerization method and commercial contact lens to modify physical and chemical properties. Ft-IR, XP, UV-vis spectrophotometer, water content, oxygen trans-metastability were used to characterize the surface state, physicochemical, and optical property of the contact lens treated with Eb. The water content and oxygen transmissibility of the contact lens treated with Eb were increased due to increase in the hydrophilic group such as O-C=O and OH group on the contact lens surface which could be produced by possible reaction between carbon and oxygen during the Eb irradiation. All of the lenses showed the high optical transmittance above 90%. In this case of B/Es, TES, Ti contact lens, the optical transmittance decreased about 5% with increasing Eb dose in the wavelength of UV-B region. The contact lens modified by Eb irradiation could improve the physical properties of the contact lens such as water content and oxygen transmissibility

  18. Formation and release of non-extractable {sup 14}C-Dicamba residues in soil under sterile and non-sterile regimes

    Energy Technology Data Exchange (ETDEWEB)

    Gevao, Bondi; Jones, Kevin C.; Semple, Kirk T

    2005-01-01

    The role of native soil microorganisms in the formation and release of non-extractable {sup 14}C-residues, previously treated with {sup 14}C-Dicamba, was investigated to examine their significance to the longer-term environmental effects on non-extractable pesticide residues. A 90 d study compared the fate of Dicamba under sterile and non-sterile regimes. In addition, soils were aged for 30 d and repeatedly extracted with a 0.01 M CaCl{sub 2} solution, to an extraction end point, to produce non-extractable residues. The extracted soil containing non-extractable residues was mixed with clean soil that had been freshly spiked with non-labeled Dicamba at 0.2 mg kg{sup -1} to increase the bulk volume of the soil and stimulate microbial activity. Sub-samples were then introduced into microcosms to compare the extent of microbially facilitated release and mineralisation with release rates in sterile microcosms. The results show that microorganisms play a significant role in the formation and release of non-extractable Dicamba residues. The release of {sup 14}C-activity in sterile microcosms was linked to physical mixing of the extracted soil with field soil prior to the beginning of the incubations. The released {sup 14}C-activity may be further mineralized, reincorporated into humus, or taken up by plants or other soil inhabiting biota.

  19. Formation and release of non-extractable 14C-Dicamba residues in soil under sterile and non-sterile regimes.

    Science.gov (United States)

    Gevao, Bondi; Jones, Kevin C; Semple, Kirk T

    2005-01-01

    The role of native soil microorganisms in the formation and release of non-extractable (14)C-residues, previously treated with (14)C-Dicamba, was investigated to examine their significance to the longer-term environmental effects on non-extractable pesticide residues. A 90 d study compared the fate of Dicamba under sterile and non-sterile regimes. In addition, soils were aged for 30 d and repeatedly extracted with a 0.01 M CaCl(2) solution, to an extraction end point, to produce non-extractable residues. The extracted soil containing non-extractable residues was mixed with clean soil that had been freshly spiked with non-labeled Dicamba at 0.2 mg kg(-1) to increase the bulk volume of the soil and stimulate microbial activity. Sub-samples were then introduced into microcosms to compare the extent of microbially facilitated release and mineralisation with release rates in sterile microcosms. The results show that microorganisms play a significant role in the formation and release of non-extractable Dicamba residues. The release of (14)C-activity in sterile microcosms was linked to physical mixing of the extracted soil with field soil prior to the beginning of the incubations. The released (14)C-activity may be further mineralized, reincorporated into humus, or taken up by plants or other soil inhabiting biota.

  20. 21 CFR 522.1020 - Gelatin solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Gelatin solution. 522.1020 Section 522.1020 Food... Gelatin solution. (a) Specifications. It is sterile and each 100 cubic centimeters contains 8 grams of gelatin in an 0.85 percent sodium chloride solution. (b) Sponsor. See No. 000856 in § 510.600(c) of this...

  1. 21 CFR 522.1225 - Ketoprofen solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Ketoprofen solution. 522.1225 Section 522.1225 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Ketoprofen solution. (a) Specifications. Each milliliter of sterile aqueous solution contains 100 milligrams...

  2. 21 CFR 522.2012 - Prostalene solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Prostalene solution. 522.2012 Section 522.2012 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Prostalene solution. (a) Specifications. Each milliliter of sterile solution contains 1 milligram of...

  3. Lens decenter and tilt measurement by interferogram

    Science.gov (United States)

    Hung, Min-Wei; Wu, Wen-Hong; Huang, Kuo-Cheng

    2009-11-01

    For the recent years, the vigorous development of the electro-optic industry, particularly the digital camera and the cellular phone camera, has placed a larger and larger demand for the optical devices. Among the optical lens, the aspherical optical lens plays the key component because the aspherical lens may provide better imaging quality then the spherical lens does. For the manufacturing reason, the aspherical lens is prone to a decenter or tilt issue with respect to the optical axes of its two surfaces. To measure decenter and tile error specifically would help to obviate the deficient lens, but most of the present measuring method can't provide this function. This paper proposed a new method to specifically measure the decenter and tile of lens by observing the interferogram of each surface. And the corresponding measuring instrument, which contains interferometer and motion stages, was introduced as well.

  4. Present studies on the radio-sterilized drugs

    International Nuclear Information System (INIS)

    Marciniec, B.; Dettlaff, K.

    2007-01-01

    Lecture presents present status of radiosterilization of drugs and medical materials as compared to other sterilization methods. Literature review is shown on degradation of different kinds of drugs sterilized upon action of the sterilising doses of radiation

  5. Present status in radiation sterilization of medical products

    International Nuclear Information System (INIS)

    Sato, Kenji

    1982-01-01

    The attempt to sterilize the disposable medical supplies of plastics and protein by radiation started as early as 1958. In the world, more than 80 such installations have been set up and operated at present. In recent years, the guarantee for sterilization has been emphasized; the trend is now for the worldwise standardization of the process control and the method of determining sterilization radiation dose. In Japan, there exist three installations equipped with 60 Co gamma -ray irradiation apparatus. The medical supplies over 20 items including artificial kidney dialyzer, injection needles and surgical stitches are radiation sterilized and practically used presently. The following matters are described: radiation sterilization facilities, sterilization process control, sterilization conditions (radiation dose), the radiation resistance of microorganisms, radiation-sterilized medical supplies. (Mori, K.)

  6. Sterile insect technique: A model for dose optimisation for improved sterile insect quality

    International Nuclear Information System (INIS)

    Parker, A.; Mehta, K.

    2007-01-01

    The sterile insect technique (SIT) is an environment-friendly pest control technique with application in the area-wide integrated control of key pests, including the suppression or elimination of introduced populations and the exclusion of new introductions. Reproductive sterility is normally induced by ionizing radiation, a convenient and consistent method that maintains a reasonable degree of competitiveness in the released insects. The cost and effectiveness of a control program integrating the SIT depend on the balance between sterility and competitiveness, but it appears that current operational programs with an SIT component are not achieving an appropriate balance. In this paper we discuss optimization of the sterilization process and present a simple model and procedure for determining the optimum dose. (author) [es

  7. Sterility maintenance assessment of moist/wet material after steam sterilization and 30-day storage.

    Science.gov (United States)

    Moriya, Giovana Abrahão de Araújo; Graziano, Kazuko Uchikawa

    2010-01-01

    Moist/wet materials stored after autoclaving are considered contaminated and not recommended for use. This study evaluates the maintenance of sterility in moist/wet material after being submitted to steam sterilization and stored for a period of 30 days. Aiming to support decision-making in emergency situations, 40 surgical boxes packed in nonwoven cloth covering Spunbound, Metblouwn, Spunbound (SMS): half (the experimental group) were placed in an autoclave but the drying phase was interrupted, yielding moist/wet materials and the other half (the negative control group) underwent the complete cycle. The external parts of each surgical box were deliberately contaminated with Serratia marcescens and subsequently stored for 30 days. After this period, the boxes' contents were submitted to sterility tests and no growth was observed. The presence of moisture inside the surgical boxes did not interfere with maintaining their sterility.

  8. Laparoscopic tubal sterilization reversal and fertility outcomes

    Directory of Open Access Journals (Sweden)

    K Jayakrishnan

    2011-01-01

    Full Text Available Purpose: The purpose of the study was two-fold. Firstly it was to assess the suitability for tubal recanalization and factors predicting successful laparoscopic recanalization. Secondly, it was to analyze the fertility outcomes and factors affecting the pregnancy rate following laparoscopic tubal recanalization. Materials and Methods: A retrospective chart review of prospectively followed-up 29 women at a tertiary care center seeking tubal sterilization reversal between May 2005 and February 2010 were included. Results: In 14 (48.3% women unilateral tubes were suitable and in only 3 women (10.3% bilateral tubes were suitable. All cases with laparoscopic tubal sterilization were suitable, whereas all cases with fimbriectomy were unsuitable for recanalization. In 6 (20.7% cases salphingostomy was performed as an alternative procedure to tubal reanastomosis. The overall pregnancy rate was 58.8%. In cases with sterilization by Pomeroy′s method, 4 out of 10 (40% conceived, whereas for laparoscopic tubal ligation cases 6 out of 7 (85.7% conceived (P=0.32. None of the patients with final tubal length <5 cm conceived (P=0.03. Comparing the age at recanalization, in women ≤30 years, 71.4% conceived, as compared with 50% when age of women was more than 30 years (P=0.37. Conclusions: The important factors determining the success of recanalization are technique of sterilization and the remaining length of the tube after recanalization. The gynecologist must use an effective technique of sterilization to minimize the failure rates, but at the same time, which causes minimal trauma, and aim at preserving the length of the tube so that reversal is more likely to be successful, should the patient′s circumstances change.

  9. Device and Container for Reheating and Sterilization

    Science.gov (United States)

    Sastry, Sudhir K.; Heskitt, Brian F.; Jun, Soojin; Marcy, Joseph E.; Mahna, Ritesh

    2012-01-01

    Long-duration space missions require the development of improved foods and novel packages that do not represent a significant disposal issue. In addition, it would also be desirable if rapid heating technologies could be used on Earth as well, to improve food quality during a sterilization process. For this purpose, a package equipped with electrodes was developed that will enable rapid reheating of contents via ohmic heating to serving temperature during space vehicle transit. Further, the package is designed with a resealing feature, which enables the package, once used, to contain and sterilize waste, including human waste for storage prior to jettison during a long-duration mission. Ohmic heating is a technology that has been investigated on and off for over a century. Literature indicates that foods processed by ohmic heating are of superior quality to their conventionally processed counterparts. This is due to the speed and uniformity of ohmic heating, which minimizes exposure of sensitive materials to high temperatures. In principle, the material may be heated rapidly to sterilization conditions, cooled rapidly, and stored. The ohmic heating device herein is incorporated within a package. While this by itself is not novel, a reusable feature also was developed with the intent that waste may be stored and re-sterilized within the packages. These would then serve a useful function after their use in food processing and storage. The enclosure should be designed to minimize mass (and for NASA's purposes, Equivalent System Mass, or ESM), while enabling the sterilization function. It should also be electrically insulating. For this reason, Ultem high-strength, machinable electrical insulator was used.

  10. Status of radiation sterilization of healthcare products in China

    International Nuclear Information System (INIS)

    Zhu Nankang; Wang Chunlei; Teng Weifang

    2004-01-01

    This paper describes the status of 60 Co radiation facilities both in service and under construction in China and examines the future market for radiation sterilization of healthcare products. Policies for developing the industry of radiation sterilization are also put forward; these include implementation of appropriate quality systems, scale-up and merging of existing radiation facilities, development of electron beam radiation for sterilization purposes and increasing awareness of the technology of radiation sterilization

  11. Sterility Maintenance Assessment of Moist/Wet Material After Steam Sterilization and 30-day Storage

    OpenAIRE

    Moriya,Giovana Abrahão de Araújo; Graziano,Kazuko Uchikawa

    2010-01-01

    Moist/wet materials stored after autoclaving are considered contaminated and not recommended for use. This study evaluates the maintenance of sterility in moist/wet material after being submitted to steam sterilization and stored for a period of 30 days. Aiming to support decision-making in emergency situations, 40 surgical boxes packed in nonwoven cloth covering Spunbound, Metblouwn, Spunbound (SMS): half (the experimental group) were placed in an autoclave but the drying phase was interrupt...

  12. [Study of the reproducibility of the sterilization process and proposal of an sterilizer requalification protocol].

    Science.gov (United States)

    Gibory, V; Robelet, A; Riou, J; Lebelle Dehaut, A-V

    2018-03-01

    Unlike EN 554, and since the publication of ISO 17665-1 standard, the user of autoclaves may use methods other than those indicated in the guidelines. Outsourcing the requalification of sterilizers by an external service provider and after observing from the previous requalification reports that the thermometric data seemed reproducible, we decided to propose and validate a validation method for the reproducibility of the sterilization process. This is to exempt from the study of the repeatability of the EN 554 standard in future requalifications. Reproducibility was studied with the sensors of the sterilization service and from the production cycles. This study was carried out in three parts. First, we checked whether our sensors were reliable. Then we evaluated the sterilization process fidelity of each sterilizer. Finally, we compared our measurements performed by the service sensors with the measurements performed by the service provider during the requalifications of the previous years. This work leads us to describe a new protocol of requalification of our sterilizers. Copyright © 2017 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  13. Comparing sterile bag rubbing and paint on technique in skin preparation of the hands.

    Science.gov (United States)

    Chou, Justin; Choudhary, Anwar; Dhillon, Raminder S

    2011-09-01

    The aim of this study was to compare two techniques for surgical site skin preparation in hand surgery. We compared the standard sponge paint technique versus a plastic bag immersion technique using a 10% povidone-iodine with alcohol solution (Betadine, ORION Laboratories Pty Ltd, Balcatta,WA,Australia) to prepare surgical site skin for hand surgery. This sterile bag rubbing technique involves using a sterile plastic bag filled with 60 mL of Betadine solution to immerse the subjects' hand. Samples were taken from 10 subjects for bacteria colony-forming unit (CFU) counts before and 3 min after surgical site preparation in each group. Outcome measures were preparation time and CFU reduction with a plate impression test using commercially available agar slides. The sterile bag rubbing technique significantly reduced (P technique (86 s). Both techniques were found to have similar efficacy in the reduction of CFU. The sterile bag rubbing technique is a quicker alternative method for surgical site preparation in hand surgery and has comparable efficacy to the widely practised standard paint-on technique.

  14. Microorganisms in the Stratosphere (MIST): In-flight Sterilization with UVC Leds

    Science.gov (United States)

    Wong, Gregory Michael; Smith, David J.

    2014-01-01

    The stratosphere (10 km to 50 km above sea level) is a unique place on Earth for astrobiological studies of microbes in extreme environments due to the combination of harsh conditions (high ultraviolet radiation, low pressure, desiccation, and low temperatures). Microorganisms in the Stratosphere (MIST) will attempt to characterize the diversity of microbes at these altitudes using a balloon collection device on a meteorological weather balloon. A major challenge of such an aerobiology study is the potential for ground contamination that makes it difficult to distinguish between collected microbes and contaminants. One solution is to use germicidal ultraviolet light emitting diodes (UV LEDs) to sterilize the collection strip. To use this solution, an optimal spatial arrangement of the lights had to be determined to ensure the greatest chance of complete sterilization within the 30 to 60 minute time of balloon ascent. A novel, 3D-printed test stand was developed to experimentally determine viable Bacillus pumilus SAFR-032 spore reduction after exposure to ultraviolet radiation at various times, angles, and distances. Taken together, the experimental simulations suggested that the UV LEDs on the MIST flight hardware should be active for at least 15 minutes and mounted within 4 cm of the illuminated surface at any angle to achieve optimal sterilization. These findings will aid in the production of the balloon collection device to ensure pristine stratospheric microbial samples are collected. Flight hardware capable of in-flight self-sterilization will enable future life detection missions to minimize both forward contamination and false positives.

  15. 21 CFR 880.6860 - Ethylene oxide gas sterilizer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ethylene oxide gas sterilizer. 880.6860 Section... Miscellaneous Devices § 880.6860 Ethylene oxide gas sterilizer. (a) Identification. An ethylene gas sterilizer is a nonportable device intended for use by a health care provider that uses ethylene oxide (ETO) to...

  16. 21 CFR 872.6710 - Boiling water sterilizer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Boiling water sterilizer. 872.6710 Section 872...) MEDICAL DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6710 Boiling water sterilizer. (a) Identification. A boiling water sterilizer is an AC-powered device that consists of a container for boiling water...

  17. 9 CFR 116.4 - Sterilization and pasteurization -records.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Sterilization and pasteurization... REPORTS § 116.4 Sterilization and pasteurization -records. Records shall be made by means of automatic... ingredients, equipment, or biological product subjected to sterilization or pasteurization. (Approved by the...

  18. 42 CFR 441.255 - Sterilization by hysterectomy.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Sterilization by hysterectomy. 441.255 Section 441.255 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Sterilizations § 441.255 Sterilization by hysterectomy. (a) FFP is not available in expenditures for a...

  19. 7 CFR 305.23 - Steam sterilization treatment schedules.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 5 2010-01-01 2010-01-01 false Steam sterilization treatment schedules. 305.23... Steam sterilization treatment schedules. Treatment schedule Temperature( °F) Pressure Exposure period (minutes) Directions T303-b-1 10 lbs 20 Use 28″ vacuum. Steam sterilization is not practical for treatment...

  20. Monitoring of steam sterilization processes in the dental office

    NARCIS (Netherlands)

    van Doornmalen, J.P.C.M.; Rietmeijer, A.G.M.; Feilzer, A.J.; Kopinga, K.

    2013-01-01

    In dental offices steam sterilization is used to prevent infection of staff and patient. The necessity of sterilization is obvious. To ensure effective sterilization processes each load has to be monitored. Based on literature and standards a state of the art concept of every load monitoring is

  1. The Coercive Sterilization of Aboriginal Women in Canada

    Science.gov (United States)

    Stote, Karen

    2012-01-01

    This paper considers the coercive sterilization of Aboriginal women in legislated and non-legislated form in Canada. I provide an historical and materialist critique of coercive sterilization. I argue for coercive sterilization to be understood as one of many policies employed to undermine Aboriginal women, to separate Aboriginal peoples from…

  2. Looking beyond the perfect lens

    International Nuclear Information System (INIS)

    Wee, W H; Pendry, J B

    2010-01-01

    The holy grail of imaging is the ability to see through anything. From the conservation of energy, we can easily see that to see through a lossy material would require lenses with gain. The aim of this paper therefore is to propose a simple scheme by which we can construct a general perfect lens, with gain-one that can restore both the phases and amplitudes of near and far fields.

  3. Study of a new radiometric sterility test in radiopharmaceuticals

    International Nuclear Information System (INIS)

    Sanchez P, A.R.

    1976-01-01

    A new radiometric method is studied for the determination of sterility. It is based on a culture marked with carbon-14 and the measurement by liquid scintillation of the radioactivity of the gaseous products released after a short period of incubation. The studied samples consisted in nonradioactive solutions and different radiopharmaceuticals, through a regulated current of nitrogen there is a transportation of gaseous and volatile products produced in each flask, which were received in a liquid scintillation vial. The experimental data permit to conclude that through the radiometric method the results can be obtained after 24 hours or less of incubation, instead of a period of several days which was necessary with the traditional process. Due to the sensitivity of the method it is possible to inoculate a minimum volume of sample, this is important in the case of the preparation of little parts for injection as it occurs generally with the pharmaceuticals. (author)

  4. CONTACT LENS RELATED CORNEAL ULCER

    Directory of Open Access Journals (Sweden)

    AGARWAL P

    2010-01-01

    Full Text Available A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are:overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. The presenting symptoms of contact lens related corneal ulcers include eye discomfort, foreign body sensation and lacrimation. More serious symptoms are redness (especially circum-corneal injection, severe pain, photophobia, eye discharge and blurring of vision. The diagnosis is established by a thorough slit lamp microscopic examination with fluorescein staining and corneal scraping for Gram stain and culture of the infective organism. Delay in diagnosing and treatment can cause permanent blindness, therefore an early referral to ophthalmologist and commencing of antimicrobial therapy can prevent visual loss.

  5. The dynamics of gynodioecy in Plantago lanceolata L. .1. Frequencies of male-steriles and their cytoplasmic male sterility types

    NARCIS (Netherlands)

    De Haan, A.A.; Luyten, R.M.J.M.; Bakx-Schotman, Tanja; Van Damme, J.M.M.

    1997-01-01

    The maintenance of a gynodioecious breeding system (hermaphrodites and male-steriles) was studied in Plantago lanceolata. Cytoplasmic-nuclear inheritance is important in the maintenance of male-steriles. The male-sterile trait is cytoplasmically based (CMS), and male fertility can be restored by

  6. [Contact lens related corneal ulcers: clinical, microbiological and therapeutic features].

    Science.gov (United States)

    Benhmidoune, L; Bensemlali, A; Bouazza, M; Karami, R; El Mansouri, H; El Belhadji, M; Rachid, R; Chakib, A; Amraoui, A

    2013-09-01

    Corneal ulcers in contact lens wearers are becoming more common, and can sometimes lead to severe complications. The purpose of this study is to define the epidemiological, clinical, microbiological and therapeutic considerations of these ulcers within the above context. We conducted an uncontrolled, descriptive, retrospective study of 51 patients presenting with contact lens related corneal ulcers to the ophthalmology department of the August 20, 1953 Hospital in Casablanca between January 2009 and January 2012. The average age of our patients was 22 years, with a gender ratio of 7.5 female to male. General risk factors (diabetes and tuberculosis) were found in 17.5% of cases. The average length of hospital stay was 15 days. Of our patients, 58.8% wore cosmetic contact lenses and 41.18% wore therapeutic contact lenses. Mean duration prior to consultation was 5 days. The predominant clinical signs were eye pain and redness, with a decrease in visual acuity worse than 1/10 in 82.3% of patients. In 70.6% of cases, the ulcer was central. The average size was 4.3mm. An anterior chamber reaction was found in 47.1%. Corneal bacterial cultures were positive in 47.8%. Pathogens found were Staphylococcus aureus, Pseudomonas aeruginosa and Acanthamœba. Contact lens and solution cultures were positive in 73.6% of cases. Outcomes were favorable with local and systemic antibiotic treatment adapted to microbiological results in only 41.2% of cases. In the remaining patients, significant secondary opacities persisted. Cosmetic and therapeutic contact lens wear is a major cause of corneal ulcer. Delayed consultation results in severe sequelae with persistently decreased visual acuity. The ophthalmologist plays an important role in preventing complications of contact lens wear, through better hygiene instruction and follow-up of his or her patients. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  7. Coelioscopic and Endoscope-Assisted Sterilization of Chelonians.

    Science.gov (United States)

    Proença, Laila M; Divers, Stephen J

    2015-09-01

    Elective sterilization is a safe and well-established surgical procedure performed in dogs and cats worldwide. Conversely, chelonian sterilization has been mostly performed therapeutically, because of the intricate anatomy and difficult access to the reproductive organs, and consequently, reproductive problems and diseases remain common. With the advance of veterinary endoscopy, novel techniques of soft tissue prefemoral coelioscopic and endoscope-assisted sterilization have been published, and preventative chelonian sterilization is now a reality. Nevertheless, extrapolations between species should be carefully considered, and further studies are warranted. This article summarizes and describes the current coelioscopic and coelioscope-assisted sterilization techniques for chelonia. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Radiation sterilization of medical products- current trends and future prospects

    International Nuclear Information System (INIS)

    Sharma, G.

    1997-01-01

    In medical practice use of sterile pharmaceuticals and single use disposable medical devices is steadily increasing. Sterile pharmaceuticals like injections and ophthalmic ointments are required for therapy. Medical devices are employed for diagnostic, drug administration or corrective purposes, and as implants for temporary, short term or long term residence in the human system. All these products are made available in sterile form by treating them to a suitable process of sterilization i.e. dry/wet heat, ethylene oxide (EtO) gas or ionizing radiation. In this paper current trends and future prospects of radiation sterilization of medical products are given in detail. 9 refs., 7 tabs

  9. Growth and optical development of the ocular lens of the squid (Sepioteuthis lessoniana).

    Science.gov (United States)

    Sivak, J G; West, J A; Campbell, M C

    1994-09-01

    Lens focal properties (spherical aberration), diameter and relative anterior/posterior proportions were measured photographically for Japanese squid (Sepioteuthis lessoniana) at ages 4-6 weeks, 7-9 weeks and 7-8 months. The measures involved photographing the refractive effects of lenses in a physiological solution, with and without an index matching fluid (polyvinylpyrroloidone solution), on a parallel array of fine helium-neon laser beams. Spherical aberration was determined from measurement of back vertex distance. Similar measurements were made on lenses from the eyes of cuttlefish (Sepia officinalis). The cephalopod lens develops as hemispheric halves from separate ectodermal sources. The posterior component contributes, on average, about 60% of axial lens diameter in S. lessoniana of all ages and 55% in S. officinalis. However, these proportions vary widely in both species. All lenses of both species show that spherical aberration is neutralized, although small variations in back vertex distance (positive and negative spherical aberration) were measured. Preliminary measures indicate that the refractive index distribution within the cephalopod lens varies in a manner reminiscent of teleost lenses. Squid lenses from animals 7-9 weeks of age were optimally corrected for spherical aberration. Some squid of this age, from a separate tank, showed a high incidence of cataract development. In each case, lens opacification was caused by deterioration of the posterior lens component.

  10. Lens gratings for dose optimization of medical X-ray phase contrast imaging.

    Science.gov (United States)

    Preusche, Oliver

    2016-11-14

    A novel way to build arrays of X-ray lenslets is proposed for use in medical imaging, in particular for X-ray phase contrast imaging. Focusing on Talbot-Lau interferometers, this work is about patient dose reduction, especially for design energies above 50 keV. A low dose poses a fabrication problem, because it requires an analyzer grating which is both fine and high: It has to be fine for a good angular sensitivity. It has to be high to absorb well. However, gratings can currently be built either fine or high. The proposed solution is to use a fine novel lens grating in front of a high analyzer grating: The lens grating uses lenslets to combine fine fringes into wider strips. This coarser pattern is then analyzed by a high grating. Regular binary production processes are sufficient to build lens gratings. Simulation-based results show that lens gratings can save dose with no impact on reconstructed images.

  11. Sterilization of activated sludges by gamma radiations

    International Nuclear Information System (INIS)

    Lacroix, J.P.; Boland, M.

    1978-01-01

    The purification process of a wastewater is described. It has been found that the great amount of sludge produced, the average value being 50 g of dry matter per inhabitant and per day, contains three species of pathogen microorganims: enteroviruses, bacteria and parasite eggs and cystes and that this microbial pollution is extremely harmful to human health. Therefore in order to manipulate as well as to use activated sludges in an agriculturad soil, a strong action against pathogen microorganisms is to be taken. Various treatment of sterilization are then described such as: pasteurization, incineration, liming, composting and by gamma radiations. The treatment by gamma radiations has been found to have many advantages in comparison with the other ones. An example of a sterilization plant located in Western Germany is given. (G.C.)

  12. A search for sterile neutrinos in MINOS

    Energy Technology Data Exchange (ETDEWEB)

    Osiecki, Thomas Henry [Univ. of Texas, Austin, TX (United States)

    2007-01-01

    MINOS, the Main Injector Neutrino Oscillation Search, is a long baseline neutrino oscillation experiment based at Fermilab National Accelerator Laboratory. The experiment uses a neutrino beam, which is measured 1 km downstream from its origin in the Near detector at Fermilab and then 735 km later in the Far detector at the Soudan mine. By comparing these two measurements, MINOS can attain a very high precision for parameters in the atmospheric sector of neutrino oscillations. In addition to precisely determining Δm$2\\atop{23}$ and θ23 through the disappearance of vμ, MINOS is able to measure vμ → vsterile by looking for a deficit in the number of neutral current interactions seen in the Far detector. In this thesis, we present the results of a search for sterile neutrinos in MINOS.

  13. Sterile neutrinos in the early universe

    Energy Technology Data Exchange (ETDEWEB)

    Malaney, R.A. (Lawrence Livermore National Lab., CA (USA)); Fuller, G.M. (California Univ., San Diego, La Jolla, CA (USA). Dept. of Physics)

    1990-11-14

    We discuss the role played by right-handed sterile neutrinos in the early universe. We show how well known {sup 4}He constraint on the number of relativistic degrees of freedom at early times limits the equilibration of the right handed neutrino sea with the background plasma. We discuss how this allows interesting constraints to be placed on neutrino properties. In particular, a new limit on the Dirac mass of the neutrino is presented. 12 refs.

  14. Laparoscopic sterilization camps--a retrospection.

    Science.gov (United States)

    Mehta, P V

    1984-04-01

    Since the Indian introduction of mass rural laparoscopic sterilization camps the procedure has proved highly acceptable, economical, speedy, and safe. Despite many couples requiring sterilization, disturbing trends have emerged in many states relating to the organization of the camps, selection of cases, pre-operative preparation, adequate experience of the operating surgeon, inadequate drugs, improper maintainence, malfunctioning of equipment, and post-operative care and follow-up. During the initial phase, it was relatively easy to draw large crowds of self-motivated acceptors; the management of these crowds in small places left much to be desired. Camps are arranged without adequate publicity through the various media. The art of laparoscopy being a highly skilled technic, Steptoe has recommended at least 1000 procedures and Phillips 500 procedures in hospitals under expert supervision, before a laparoscopist can operate independently in camps. The equipment should be properly maintained and enough spares should be at hand. For the desired projection to stabilize the birth rate at 25/1000, the sterilization camps approach through quick, safe, economical, and easy laparoscopic sterilization technic is not a dream but a reality to be experienced. The vastness of the work requires many well trained doctors in this technic, who should be given exemption from income tax if they serve the rural population; thus, the brain drain will stop, and many emigrating doctors will be able to make a living. Overall, the commitment of policy makers to satisfy the masses who want to participate in this successful program is the only hope to save the bleak future.

  15. Sperm antibody production in female sterility.

    Science.gov (United States)

    Mettler, L; Scheidel, P; Shirwani, D

    1974-01-01

    A review of the immunological implications in reproductive physiology is presented. Although attempts have been made to ascribe the antigenicity of semen to individual components, it has not been possible to isolate the human semen antigen responsible for infertility. In monkeys total ejaculates and seminal plasma have shown higher antigenicity than washed spermatozoa. In bulls some evidence of such antigens have been found in the seminal plasma. They are iron-binding proteins resembling lactoferrin. Most investigators have found no evidence for any participation of the ABO blood group antigens in cases of sterility. On the surface of human spermatozoa histo-incompatibility antigens have been detected. Transplantation antigens may be related to sterility. However, an immulogic tolerance of the maternal organism exists against the genetically foreign fetal tissue. Autoimmune spermagglutinating antibodies have been detected in the sera and in the seminal plasma of males with sterility. An obstruction of the seminal pathways may facilitate the production of such antibodies against retained sperm. Isoimmunity in females against seminal components has been shown in cases of sterility; however, fertile women have also been shown to have such conditions. In a group of infertile women spermagglutination activity was detected in 7.5% of cases. In another series of 46 cases with primary unexplained infertility agglutinating antibodies were found in 17.4%. Other investigators have also reported higher rates than the authors. The sperm immobilization test seems to be more sensitive than the agglutination test. No sera were found positive with both tests. With immunofluorescent techniques humoral sperm antibodies have been found to be the IgM and IgG fractions. Each acts on a different part of the spermatozoa. The only promising therapy against humoral sperm antibodies is avoidance of sperm contact over a long period of time. Reported results have been conflicting. Cortisone

  16. Sterilization: new method options, failure rate info.

    Science.gov (United States)

    1998-01-01

    This article discusses new sterilization methods for tubal ligation, failure rates, and risks for ectopic pregnancy in the US. The Filshie clip, which was developed by Femcare, Ltd. in Nottingham, England, and is distributed by Avalon Medical Corp of Vermont, was approved by the US Food and Drug Administration in September 1996. The company has provided training sessions at major universities nationwide and exhibited at national professional association meetings. A training video and two more films will be available in 1998. The new clip is considered a more modern approach to a tubal occlusion method, which relies on newer materials and solves prior problems. Physicians usually used Falope rings, which had better failure rates than the Hulka clip and bipolar coagulation methods. There is a need for more long-term and large scale information exchange about the new Filshie clip. Some physicians still use the Falope ring because it is cost effective and well-studied. Physicians are warned to continue to advise women about the potential failure rates up to 10 years after sterilization and the 1 in 3 risk of ectopic pregnancy. Counseling about failure rates and the risk of ectopic pregnancy should target women under 30 years old, who have the highest failure rates, and women 30-34 years old. All sterilized women should be advised to seek a provider immediately if they have pregnancy symptoms following sterilization. Counseling should include the issue of "regrets," since it is a permanent method. All women should know about nonpermanent methods and experience a basic informed consent process. Young women and newly divorced women are particularly vulnerable to the "regrets" syndrome.

  17. Dose mapping for documentation of radiation sterilization

    DEFF Research Database (Denmark)

    Miller, A.

    1999-01-01

    The radiation sterilization standards EN 552 and ISO 11137 require that dose mapping in real or simulated product be carried in connection with the process qualification. This paper reviews the recommendations given in the standards and discusses the difficulties and limitations of practical dose...... mapping. The paper further gives recommendations for effective dose mapping including traceable dosimetry, documented procedures for placement of dosimeters, and evaluation of measurement uncertainties. (C) 1999 Elsevier Science Ltd. All rights reserved....

  18. Light Sterile Neutrinos from Large Extra Dimensions

    OpenAIRE

    Ma, Ernest; Rajasekaran, G.; Sarkar, Utpal

    2000-01-01

    An experimentally verifiable Higgs-triplet model of neutrino masses from large extra dimensions was recently proposed. We extend it to accomodate a light sterile neutrino which also mixes with the three active neutrinos. A previously proposed phenomenological model of four neutrinos (\\underline {the only viable such model now left}, in view of the latest atmospheric and solar neutrino-oscillation data) is specifically realized.

  19. Irradiation sterilization of semi-crystalline polymers

    International Nuclear Information System (INIS)

    Williams, J.; Dunn, T.; Stannett, V.

    1978-01-01

    A semi-crystalline polymer such as polypropylene, is sterilized by high energy irradiation, with the polymer containing a non-crystalline mobilizing additive which increases the free volume of the polymer, to prevent embrittlement of the polymer during and subsequent to the irradiation. The additive has a density of from 0.6 to 1.9 g/cm 3 and a molecular weight from 100 to 10,000 g/mole

  20. Psychosexual adjustment following sterilization: a prospective study on Chinese women.

    Science.gov (United States)

    Tang, C S; Chung, T K

    1997-02-01

    The present study aimed to identify significant predictors of Chinese women's psychosexual adjustment after sterilization. One hundred fifteen multiparous Chinese women, aged 25-51 years, were interviewed before and after elective laparoscopic or postpartum sterilization. Eight-seven women were also interviewed about their pshychosexual adjustment at 1 year after sterilization. Results showed that the fear of negative evaluation by others, family cohesion and adaptability, and preoperative psychological distress were robust predictors of adverse psychosexual outcome immediately and 1 year after sterilization. There was significant improvement in women's mental health following sterilization, and their sexual adjustment such as coital frequency and sexual satisfaction were not adversely affected at 1 year follow-up. Women with either elective or postpartum sterilization had similar adjustment throughout, except the latter group tended to experience more physical discomfort at 1 year follow-up. About 3.4% of the women experienced regret at 12 months after sterilization.

  1. Possible environmental sources of Acanthamoeba spp in contact lens wearers.

    Science.gov (United States)

    Seal, D; Stapleton, F; Dart, J

    1992-01-01

    The water supply and dust samples from the home environment (bathrooms and kitchens) of 50 wearers of contact lenses (CLs) were cultured for the presence of free-living amoebae. CL cases, solutions, and water taps were cultured for bacteria, which amoebae require for growth. Acanthamoeba spp were isolated from water drawn from six bathroom cold water taps (tank supplied), five in the presence of limescale, and from one kitchen cold water tap (mains supplied). There was an association between the presence of limescale in water and direct culture for free-living amoebae, suggesting that scale provides a favourable microenvironment for amoebae. Acanthamoebae were also found in dust from around one washbasin. Nineteen of 50 CL cases, 12/122 CL care rinsing solutions, and 59/100 cold water taps yielded Gram negative bacteria which could be ingested by amoebae. It is concluded from this study that CLs should not be washed in first-drawn tank-fed cold water, especially if limescale is present, and that soft CLs should be rinsed in manufactured single-use, sterile solutions. Rigid CL and CL cases should only be washed with boiled tap water (preferably hot), or single-use sterile solutions, and stored dry to prevent multiplication of amoebae and Gram negative bacteria. PMID:1627513

  2. Primary intraocular lens implantation for penetrating lens trauma in Africa.

    Science.gov (United States)

    Bowman, R J; Yorston, D; Wood, M; Gilbert, C; Foster, A

    1998-09-01

    This study aimed to audit the surgical strategy of primary posterior chamber intraocular lens implantation for cases of recent penetrating trauma involving the lens in an African population. Retrospective, noncomparative case series. Seventy-two cases are reported, including all patients who underwent primary intraocular lens implantation for traumatic cataract extraction performed within 1 month of injury between 1988 and 1996. Demographic characteristics and follow-up attendance rates are analyzed. Surgical technique and the occurrence of intraoperative and postoperative complications are reported. Visual outcomes are reported with detailed analysis for cases of poor visual outcome. Mean age was 14.3 years (standard deviation = 11.1), 57 (79%) were male and 15 (21%) were female (chi-square = 23.66, P capsule had been breached by the trauma in 27 (38%) cases, and 15 of these required anterior vitrectomy. Capsular fixation of the implant was achieved in 49% of patients, the remainder having sulcus fixation. Intraoperative rupture of the posterior capsule occurred in four cases. The only common postoperative complication was acute fibrinous anterior uveitis, which occurred in 29 (40%) patients, and 32% of patients followed up for at least 6 months required secondary posterior capsulotomy. This was more common in younger patients (chi-square = 4.2, P < 0.05). Corrected postoperative visual acuities were available for 51 patients, of which 71% achieved 20/60 or better visual acuity. Patients 6 years of age or younger were less likely to achieve 20/60 (chi-square = 6.61, P = 0.01). This surgical strategy has proved successful, producing good visual results and causing no sight-threatening complications. Primary posterior capsulotomy may be appropriate for younger patients.

  3. [Essure--a novel method of sterilization].

    Science.gov (United States)

    Revel, Ariel; Nadjary, Michel; Shushan, Asher

    2008-02-01

    Essure hysteroscopic sterilization is a minimally invasive, outpatient approach to female sterilization, which avoids the possible complications of laparoscopic sterilization. This procedure has been available since 2003 in both Europe and North America. We present our experience of the first 12 cases of the procedure performed in Israel. Women who have completed their family planning were offered to consider Essure as their permanent contraception. The procedure was performed without anesthesia by the vaginoscopic technique at the hospital's outpatient clinic. Patients completed a questionnaire and were discharged immediately following the procedure. A follow-up checkup was completed after three months including three dimensional sonography, abdominal X-ray and occasional hysterosalpingogram. Twelve patients participated in the pilot group at Hadassah. The average age was 40 years (34-45) and the average number of children was 5 (4-8). The average time for the procedure was under 8 minutes. Periostial adhesions required adhesiolysis prior to insertion of the device in one patient. All patients resumed their normal activity on the same day. Our patient satisfaction survey revealed that the procedure was associated with high satisfaction levels. Sonographic and radiographic studies confirmed the good placement of the device. The Essure procedure was well tolerated by patients. The limitation is probably going to be the price of Essure, as this procedure is not covered by the 'health basket' in Israel.

  4. Sterilization by ionizing radiation comparative evaluation

    International Nuclear Information System (INIS)

    Tata, A.; Giuliani, S.

    1996-01-01

    Sterilization of surgical and medical devices by ionizing radiation (gamma or accelerated electron beams) is currently regarded as one of the main industrial-scale applications of radiation technology processes. Considering the most widely utilized chemical-physical methods (i.e. ethylene oxide (EtO) fumigation and radiation treatment), about 10-12 millions m(3) of surgical and medical devices are estimated to be processed yearly all around the world, of which 7 on beams. Due to the increasing demand for reusable and single-use devices, and the need of assuring their sterility in order to prevent, as much as possible, the diffusion of serious infective diseases (among which for instance Aids), the market of sterilization of these items is considerably expanding. In the general depicted scenario, radiation technologies are expected to gain a leading role, even a part from their economic attractiveness, as an alternative to EtO treatment, which is more and more considered as responsible for increasing environmental, social and public health problems

  5. Standardized Method for High-throughput Sterilization of Arabidopsis Seeds.

    Science.gov (United States)

    Lindsey, Benson E; Rivero, Luz; Calhoun, Chistopher S; Grotewold, Erich; Brkljacic, Jelena

    2017-10-17

    Arabidopsis thaliana (Arabidopsis) seedlings often need to be grown on sterile media. This requires prior seed sterilization to prevent the growth of microbial contaminants present on the seed surface. Currently, Arabidopsis seeds are sterilized using two distinct sterilization techniques in conditions that differ slightly between labs and have not been standardized, often resulting in only partially effective sterilization or in excessive seed mortality. Most of these methods are also not easily scalable to a large number of seed lines of diverse genotypes. As technologies for high-throughput analysis of Arabidopsis continue to proliferate, standardized techniques for sterilizing large numbers of seeds of different genotypes are becoming essential for conducting these types of experiments. The response of a number of Arabidopsis lines to two different sterilization techniques was evaluated based on seed germination rate and the level of seed contamination with microbes and other pathogens. The treatments included different concentrations of sterilizing agents and times of exposure, combined to determine optimal conditions for Arabidopsis seed sterilization. Optimized protocols have been developed for two different sterilization methods: bleach (liquid-phase) and chlorine (Cl2) gas (vapor-phase), both resulting in high seed germination rates and minimal microbial contamination. The utility of these protocols was illustrated through the testing of both wild type and mutant seeds with a range of germination potentials. Our results show that seeds can be effectively sterilized using either method without excessive seed mortality, although detrimental effects of sterilization were observed for seeds with lower than optimal germination potential. In addition, an equation was developed to enable researchers to apply the standardized chlorine gas sterilization conditions to airtight containers of different sizes. The protocols described here allow easy, efficient, and

  6. Interpreting the LSND anomaly sterile neutrinos or CPT-violation or...?

    CERN Document Server

    Strumia, A

    2002-01-01

    We first study how sterile neutrinos can fit the 5sigma bar-nu_mu --> bar-nu_e LSND anomaly: 3+1 solutions give a poor fit, but better than than 2+2 solutions (the best fit regions are somewhat different, so that MiniBoone could discriminate). If instead MiniBoone will find no nu_mu --> nu_e signal, we will have a hint for CPT violation. Already now, unlike sterile neutrinos, CPT-violating neutrino masses can nicely accomodate all safe and unsafe data. We study how much CPT must be conserved according to atmospheric and K2K data and list which CPT-violating signals could be discovered by forthcoming solar and long-baseline experiments.

  7. Research on one manual zoom liquid lens

    Science.gov (United States)

    Zhao, Cunhua; Shi, Yongpeng; Li, Wenjiao; Li, Congcong

    2011-11-01

    In liquid zoom lens, the accurate fixed-focus location needs the accurate calculation of focal length. That is to say, the accurate calculation of surface curvature must be obtained. Therefore, the research of their relation in liquid zoom lens becomes extremely important which has a directly theoretical instruction for the design of liquid zoom lenses. In our paper, the relation is studied. A manual liquid lens is reported which has upper and nether components with specificaton Φ12×5mm. The zoom lens is obtained by the upper component circumvolving down into the nether components.

  8. Numerical analyses of planer plasmonic focusing lens

    Science.gov (United States)

    Chou, Yen-Yu; Lee, Yeeu-Chang

    2018-03-01

    The use of polystyrene (PS) sphere lithography has been widely applied in the fabrication of micron and nano structures, due to their low cost and ease of fabrication in large scale applications. This study evaluated the feasibility of plasmonic lens base on metal thin films with nanohole structures fabricated by using PS sphere lithography through three-dimensional (3D) finite difference time domain (FDTD) method. We calculated the intensity profile of lens with various wavelength of incident light, lens size, cutting positions, diameters of nanohole, and periods of nanohole to investigate the geometric parameters influence on the focusing properties of the plasmonic lens.

  9. Sterilizing Endodontic Files by four different sterilization methods to prevent cross-infection - An In-vitro Study.

    Science.gov (United States)

    Raju, T B V G; Garapati, Satish; Agrawal, Rupika; Reddy, Sridhara; Razdan, Ankur; Kumar, S Kishore

    2013-12-01

    Aim of the study was to compare 4 different methods of sterilizing endodontic files in dental practice. The present study was performed on 100 K-files, 21 mm long and of size 25. Of these, 20 files were taken as control group, and the remaining 80 files were divided into 4 groups of 20 files each and they were tested for the efficacy of sterilization with different methods: Autoclave, glass bead, glutaraldehyde and CO2 laser. The study showed that the files sterilized by autoclave and lasers were completely sterile. Those sterilized by glass bead were 90% sterile and those with glutaraldehyde were 80% sterile. The study concluded that autoclave or laser could be used as a method of sterilization in clinical practice and in advanced clinics; laser can be used also as a chair side method of sterilization. How to cite this article: Raju TB, Garapati S, Agrawal R, Reddy S, Razdan A, Kumar SK. Sterilizing Endodontic Files by four different sterilization methods to prevent cross-infection - An In-vitro Study. J Int Oral Health 2013; 5(6):108-12 .

  10. Exchange of tears under a contact lens is driven by distortions of the contact lens.

    Science.gov (United States)

    Maki, Kara L; Ross, David S

    2014-12-01

    We studied the flow of the post-lens tear film under a soft contact lens to understand how the design parameters of contact lenses can affect ocular health. When a soft contact lens is inserted, the blinking eyelid causes the lens to stretch in order to conform to the shape of the eye. The deformed contact lens acts to assume its un-deformed shape and thus generates a suction pressure in the post-lens tear film. In consequence, the post-lens tear fluid moves; it responds to the suction pressure. The suction pressure may draw in fresh fluid from the edge of the lens, or it may eject fluid there, as the lens reassumes its un-deformed shape. In this article, we develop a mathematical model of the flow of the post-lens tear fluid in response to the mechanical suction pressure of a deformed contact lens. We predict the amount of exchange of fluid exchange under a contact lens and we explore the influence of the eye's shape on the rate of exchange of fluid. © The Author 2014. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.

  11. Sensitivity of viruses to radiation sterilization

    International Nuclear Information System (INIS)

    Dziedzic Goclawska; A

    1999-01-01

    The hazard of infectious disease transmission with tissue allografts is a major concern in tissue banking practice. Microorganisms can be introduced into grafts during tissue collection, processing and storage, but even when all these procedures are performed under a septic conditions, the possibility of fungal, bacterial or viral disease transmission of donor origin can not be excluded. Therefore, in order to minimize the risk of infectious disease transmission, several steps should be undertaken, including a careful donor screening, proper tissue processing and sterilization of tissue allografts. The risk of transmission of viral infections such as hepatitis B, C, other viruses and particularly HIV with tissue allografts is of great significance and the search for sterilizing methods which inactivate and/or highly reduce viral infectivity continues. Sterilization of tissue allografts with ionizing radiation (introduced in the mid of 1950s) is increasingly used in tissue banking practice. The effectiveness of the radiation-sterilization procedure depends on the amount of energy transferred, the number of contaminating microorganisms and their resistance to ionizing radiation (initial contamination, bioburden). Usually, spores are more resistant than vegetative forms of bacteria, some fungi may be as resistant as bacterial spores, and viruses are, in general, more resistant than bacteria. Dita concerning effectiveness of ionizing radiation to inactivate viruses (e.g. such as HBV, HCV or HIV) in tissue allografts collected from cadavers are scarce. It has been found that the dose of irradiation needed to reduce HIV load by I log10 unit (D10) is about 4.0 kGy or even 5.6 kGy. The level of infectious HIV in plasma is usually evaluated by titration of tissue culture infective dose (TCID50/ml). Taking into consideration the recommended sterility assurance level (SAL) 10-6, assuming the HIV bioburden to be 103 TCID50/ml for the state of acute infection and D10 value of 4

  12. Proceedings of 3. autumn school of radiation sterilization of medical utensils and grafts

    International Nuclear Information System (INIS)

    1995-01-01

    The Polish experience and review of worldwide development of radiation techniques and technologies have been presented and discussed in the field of radiation sterilization of medical supplies and grafts as well as for food processing. These problems have found now in Poland industrial or pilot plant solutions. Also some technologies connected with medical utensils production from with polymeric material resistant for radiation have been developed in Poland

  13. pH Dependence of Microbe Sterilization by Cationic Antimicrobial Peptides

    OpenAIRE

    Walkenhorst, William F.; Klein, J. Wolfgang; Vo, Phuong; Wimley, William C.

    2013-01-01

    We recently described a family of cationic antimicrobial peptides (CAMPs) selected from a combinatorial library that exhibited potent, broad-spectrum activity at neutral pH and low ionic strength. To further delimit the utility and activity profiles of these peptides, we investigated the effects of solution conditions, such as pH and ionic strength, on the efficacy of the peptide antimicrobials against a panel of microorganisms. Peptide minimum sterilizing concentrations (MSCs) varied linearl...

  14. SIMION, Electrostatic Lens Analysis and Design

    International Nuclear Information System (INIS)

    Dahl, David A.

    2001-01-01

    1 - Description of program or function: SIMION is an electrostatic lens analysis and design program. In SIMION an electrostatic lens is defined as a two-dimensional electrostatic potential array containing both electrode and non-electrode points. The potential array is refined using over-relaxation methods allowing voltage contours and ion trajectories to be computed and plotted. Planar and cylindrical symmetry assumptions allow the two-dimensional fields to support three-dimensional ion trajectory calculations. In addition, the user has the option of writing simple programs which can among other actions control field scale factors, dynamically adjust electrodes, and define explicit three-dimensional field functions (e.g. a quadrupole) used in lieu of array fields in specified portions of the potential array. Magnetic fields can be specified for computing ion trajectories in many electrostatic and magnetic field environments. An interactive graphics interface that uses a high resolution color display and mouse allows the user to view electrodes, trajectories, and contours on the screen prior to plotting, and a memory zoom feature permits expansion of selected areas in the current view. The mouse can be operated to edit the potential array, initialize voltage gradients, or resize the potential array. 2 - Method of solution: SIMION is designed to model the electrostatic fields and forces created by a collection of shaped electrodes given certain symmetry assumptions. The electrostatic fields are modeled as boundary value problem solutions of a Laplace elliptical partial differential equation. A finite difference technique called dynamically self-adjusting over-relaxation is applied to the two-dimensional potential array of points representing electrode and non-electrode regions to obtain a best estimate of the voltages for those points within the array that depict non-electrode regions. A standard fourth-order Runge-Kutta method is used for numerical integration of

  15. Electron sterilization validation techniques using the controlled depth of sterilization process

    Science.gov (United States)

    Cleghorn, Denise A.; Nablo, Sam V.

    Many pharmaceutical products, especially parenteral drugs, cannot be sterilized with gamma rays or high energy electrons due to the concomitant product degradation. most of these products are filled under aseptic conditions so that for qualification as a sterile product, techniques are often required only for treatment of the container surfaces and package interior. Gas sterilization (ETO) is often used for this purpose but is beset with difficulties known to the reader, especially for critical "contact" products such as in the ophthalmic field. In view of the well-controlled electron energy spectrum available in modern electron processors, it is practical to deliver sterilizing doses over depths considerably less than those defining the thickness of blister-pack constructions or pharmaceutical containers. Because bremsstrahlung and x-ray production are minimized at these low electron energies and in these low Z materials, very high electron: penetrating x-ray dose ratios are possible for the application of the technique. Some of these data illustrating package: parenteral ratios of 10 5:1 have been reported (Rangwalla et al, 1985; Aaronson and Nablo, 1988). Standard techniques have been developed for the validation of the process and are reported here. Thin film dosimetric techniques have been developed utilizing radiochromic film in the 10-60 g/m 2 range for determining the surface dose distribution in occluded surface areas where direct electron illumination is not possible. Procedures for validation of the process using dried spore inoculum on the product as well as in good geometry are employed to determine the process lethality and its dependence on product surface geometry. Applications of the process to labile pharmaceuticals in glass and polystyrene syringes are reviewed. It has been applied to the sterilization of commercial sterile products since 1987, and the advantages and the natural limitations of the technique are discussed.

  16. Use of sterile insect technique in Brazil by the sterilization of Ceratitis capitata (Wied., 1824)

    International Nuclear Information System (INIS)

    Okeese, G.O.; Kitomer, T.J.; Gayaradus, L.B.; Etrigan, M.; Jansen, C.W.J.H.; Houlahar, H.L.

    2006-01-01

    The Sterile Insect Technique is a method of pest control allowed in Integrated Pest Management programs in fruit growing, where sterile insects released compete in mate process against fertile wild ones, generating a gradative population reduction. The most used sterilization method is using ionizing radiation from 60 Co or 137 Cs. For efficient application of SIT, an important item is the sterilizing dose. This must be as lower as possible in order to preserve insect behavior. In this work, it was studied the reproductive potential of fruit fly Ceratitis capitata, tsl VIENNA 8 strain, irradiated with different doses of gamma radiation. This strain has been used in population suppression programs at fruit-growing areas from Northeast of Brazil, through a partnership between CENA and Bio factory MOSCAMED Brazil, intending only sterile male releases. Radiation source used was a 60 Co irradiator, with 17.2 x 1012 Bq. Individualized couples were distributed in a randomized delineament with 10 replicates for each treatment and eggs were collected for fifteen days. With 9 and 10 days old, pupae were irradiated with doses ranging from 30 to 120 Gy. All averages of emerged adult's percentages were higher than 90%. In regards to fecundity, different doses did not affect the number of eggs laid, being the overall mean around 30 eggs/couple/day. Fertility data showed that as radiation dose increases, sterility increases. It was concluded that the dose of 90 Gy can be used in Brazil, since to SIT programs a dose is chosen witch prevents an egg hatch higher than 1%. (author)

  17. Obstetric Outcomes After Failed Hysteroscopic and Laparoscopic Sterilization Procedures.

    Science.gov (United States)

    Brandi, Kristyn; Morgan, Jake R; Paasche-Orlow, Michael K; Perkins, Rebecca B; White, Katharine OʼConnell

    2018-02-01

    To compare obstetric outcomes after failed hysteroscopic and laparoscopic sterilization. This retrospective cohort study examined pregnancy outcomes including live birth, preterm birth, stillbirth, spontaneous abortion, therapeutic abortion, ectopic pregnancies, and gestational trophoblastic disease using a commercial claims administrative database for the years 2007-2013. We used a Z-test to compare pregnancy outcomes per 100 person-years based on type of sterilization. Cox proportional hazard models controlled for patient age, geographic region, urbanicity, comorbidities, and insurance type. We evaluated 997 pregnancy outcomes among 817 women from a total of 70,115 women with a history of either hysteroscopic sterilization (n=387 pregnancies/27,724 cases) or laparoscopic sterilization (n=610 pregnancies/42,391 cases). Women undergoing hysteroscopic sterilization were slightly older than, but otherwise similar to, women undergoing laparoscopic sterilization. The most common outcome was live birth, which was more likely after hysteroscopic sterilization compared with laparoscopic sterilization (adjusted hazard ratio 1.32, 95% CI 1.09-1.60). The rate of spontaneous abortion was not statistically significantly different between the two groups. Therapeutic abortion occurred more often after hysteroscopic sterilization (adjusted hazard ratio 1.49, 95% CI 1.10-2.01), whereas ectopic pregnancies occurred less often (adjusted hazard ratio 0.12, 95% CI 0.05-0.29) compared with laparoscopic sterilization. Hysteroscopic sterilization is associated with higher rates of live birth and lower rates of ectopic pregnancy compared with laparoscopic sterilization. Spontaneous abortion and preterm birth rates were similar in both groups. These data do not support an adverse effect of hysteroscopic sterilization on subsequent pregnancy outcomes.

  18. Clinical Presentation and Microbial Analyses of Contact Lens Keratitis; an Epidemiologic Study.

    Science.gov (United States)

    Rasoulinejad, Seyed Ahmad; Sadeghi, Mahmoud; Montazeri, Mohammad; Hedayati Goudarzi, Hesam; Montazeri, Mahmood; Akbarian, Nadali

    2014-01-01

    Microbial keratitis is an infective process of the cornea with a potentially and serious visual impairments. Contact lenses are a major cause of microbial keratitis in the developed countries especially among young people. Therefore, the purpose of the present study was to evaluate the frequency and microbiological characteristic of CLK in patients referred to the emergency department (ED) of teaching hospitals, Babol, Iran. This is a cross-sectional study of all patients with contact lens induced corneal ulcers admitted to the teaching hospitals of Babol, Iran, from 2011- 2013. An ophthalmologist examined patients with the slit-lamp and clinical features of them were noted (including pain, redness, foreign body sensation, chemosis, epiphora, blurred vision, discomfort, photophobia, discharge, ocular redness and swelling). All suspected infectious corneal ulcers were scraped for microbial culture and two slides were prepared. Data were analyzed using SPSS software, version 18.0. A total of 14 patients (17 eyes) were recruited into the study (100% female). The patients' age ranged from 16-37 years old (mean age 21.58±7.23 years). The most prevalent observed clinical signs were pain and redness. Three samples reported as sterile. The most common isolated causative organism was pseudomonas aeroginosa (78.6%), Staphylococcus aureus 14.3%, and enterobacter 7.1%, respectively. Treatment outcome was excellent in 23.5%, good in 47.1%, and poor in 29.4% of cases. Improper lens wear and care as well as the lack of awareness about the importance of aftercare visits have been identified as potential risk factors for the corneal ulcer among contact lens wearers. Training and increasing the awareness of adequate lens care and disinfection practices, consulting with an ophthalmologist, and frequent replacement of contact lens storage cases would greatly help reducing the risk of microbial keratitis.

  19. Clinical Presentation and Microbial Analyses of Contact Lens Keratitis; an Epidemiologic Study

    Directory of Open Access Journals (Sweden)

    Seyed Ahmad Rasoulinejad

    2014-09-01

    Full Text Available Introduction: Microbial keratitis is an infective process of the cornea with a potentially and serious visual impairments. Contact lenses are a major cause of microbial keratitis in the developed countries especially among young people. Therefore, the purpose of the present study was to evaluate the frequency and microbiological characteristic of CLK in patients referred to the emergency department (ED of teaching hospitals, Babol, Iran. Methods: This is a cross-sectional study of all patients with contact lens induced corneal ulcers admitted to the teaching hospitals of Babol, Iran, from 2011- 2013. An ophthalmologist examined patients with the slit-lamp and clinical features of them were noted (including pain, redness, foreign body sensation, chemosis, epiphora, blurred vision, discomfort, photophobia, discharge, ocular redness and swelling. All suspected infectious corneal ulcers were scraped for microbial culture and two slides were prepared. Data were analyzed using SPSS software, version 18.0. Results: A total of 14 patients (17 eyes were recruited into the study (100% female. The patients’ age ranged from 16-37 years old (mean age 21.58±7.23 years. The most prevalent observed clinical signs were pain and redness. Three samples reported as sterile. The most common isolated causative organism was pseudomonas aeroginosa (78.6%, Staphylococcus aureus 14.3%, and enterobacter 7.1%, respectively. Treatment outcome was excellent in 23.5%, good in 47.1%, and poor in 29.4% of cases. Conclusion: Improper lens wear and care as well as the lack of awareness about the importance of aftercare visits have been identified as potential risk factors for the corneal ulcer among contact lens wearers. Training and increasing the awareness of adequate lens care and disinfection practices, consulting with an ophthalmologist, and frequent replacement of contact lens storage cases would greatly help reducing the risk of microbial keratitis.

  20. Primary anterior chamber intraocular lens for the treatment of severe crystalline lens subluxation.

    Science.gov (United States)

    Hoffman, Richard S; Fine, I Howard; Packer, Mark

    2009-10-01

    Subluxated cataractous and clear lenses are commonly treated by limbal or pars plana lensectomy followed by primary or secondary intraocular lens (IOL) implantation. Adjunctive capsular prosthetic devices have facilitated lens removal and IOL centration in these challenging cases but have also added complexity and potential complications to the procedure. Although crystalline lens extraction may be required to clear the visual axis in mild to moderate lens subluxations, we propose insertion of a primary anterior chamber IOL without lens extraction in severe subluxations when the eye is optically aphakic or can be made functionally aphakic following neodymium:YAG laser zonulysis. Two cases demonstrating this approach are presented.

  1. Protection of the eye lens

    International Nuclear Information System (INIS)

    2015-01-01

    The limit of radiation exposure for eye lens is going to decrease dramatically from 150 to 20 mSv as a transposition into the French law of a CIPR (International Commission for Radiation Protection) directive. Sanitary studies have shown that radiologists are more likely by a factor of 3.8 to get eye lens opacities than the rest of the population. The wearing of protective glasses is recommended and in order to get a better monitoring of the radiation dose new dosimeters have been designed, they can be worn on the glass frame of directly stuck on the skin near the eyes. A study has shown that veterinary surgeons that are accustomed to stay near animals to keep them quiet during radiological exams are prone to receive high doses as well as physicians that use hypnosis to decrease the level of anxiety of their patients during radiological exams. Radiation exposure of radiologists can be mitigated through: the use of protective shields and equipment and the optimization of the dose delivered to the patient. (A.C.)

  2. Supercritical carbon dioxide-based sterilization of decellularized heart valves

    Science.gov (United States)

    Hennessy, Ryan S.; Jana, Soumen; Tefft, Brandon J.; Helder, Meghana R.; Young, Melissa D.; Hennessy, Rebecca R.; Stoyles, Nicholas J.; Lerman, Amir

    2017-01-01

    Objective The goal of this research project encompasses finding the most efficient and effective method of decellularized tissue sterilization. Background Aortic tissue grafts have been utilized to repair damaged or diseased valves. Although, the tissues for grafting are collected aseptically, it does not eradicate the risk of contamination nor disease transfer. Thus, sterilization of grafts is mandatory. Several techniques have been applied to sterilize grafts; however, each technique shows drawbacks. In this study, we compared several sterilization techniques: supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide for impact on the sterility and mechanical integrity of porcine decellularized aortic valves. Methods Valve sterility was characterized by histology, microbe culture, and electron microscopy. Uniaxial tensile testing was conducted on the valve cusps along their circumferential orientation to study these sterilization techniques on their integrity. Results Ethanol-peracetic acid and supercritical carbon dioxide treated valves were found to be sterile. The tensile strength of supercritical carbon dioxide treated valves (4.28 ± 0.22 MPa) was higher to those valves treated with electrolyzed water, gamma radiation, ethanol-peracetic acid and hydrogen peroxide (1.02 ± 0.15, 1.25 ± 0.25, 3.53 ± 0.41 and 0.37 ± 0.04 MPa, respectively). Conclusions Superior sterility and integrity were found in the decellularized porcine aortic valves with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. Summary Sterilization of grafts is essential. Supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide techniques were compared for impact on sterility and mechanical integrity of porcine decellularized aortic valves. Ethanol-peracetic acid and supercritical carbon dioxide treated

  3. Color corrected Fresnel lens for solar concentration

    International Nuclear Information System (INIS)

    Kritchman, E.M.

    1979-01-01

    A new linear convex Fresnel lens with its groove side down is described. The design philosophy is similar to the highly concentrating two focal Fresnel lens but including a correction for chromatic aberration. A solar concentration ratio as high as 80 is achieved. For wide acceptance angles the concentration nears the theoretical maximum. (author)

  4. Modified suturing contact lens for penetrating keratoplasty.

    Science.gov (United States)

    Kramer, S G; Stewart, H L

    1978-11-01

    The authors have previously described a suturing contact lens that protects the corneal endothelium by aiding in the maintenance of the anterior chamber during penetrating keratoplasty. This report describes structural modifications of the suturing contact lens, which improve its stability and effectiveness. An additional configuration for use in corneal lacerations is presented.

  5. Plant's sterilization rule for fertile women cited.

    Science.gov (United States)

    1979-01-01

    The American Cyanamid Corporation has been cited by the Occupational Safety and Health Administration (OSHA) for violating federal law by requiring female employees of childbearing age to be sterilized in order to continue working in areas of the plant where they would be exposed to high levels of airborne lead. High levels of airborne lead can cause damage to workers' reproductive systems and be responsible for birth defects in fetuses. The OSHA charged that American Cyanamid's policy constituted a "willful violation" of the 1970 Occupational Safety and Health Act. The Act requires employers to provide employment that is free from recognized hazards likely to cause death or physical harm. According to OSHA, the Act does not allow an employer to eliminate the hazard by compelling employees to choose between losing their jobs and undergoing sterilization. The reproductive health of workers is considered a valid part of OSHA's regulatory concern. The citation, which carries a $10,000 fine, grew out of a complaint that was filed by the Oil, Chemical and Atomic Workers Union on behalf of 5 female workers working in the lead pigment division of the company's Willow Island, West Virginia plant. The 5 employees alleged that they had themselves sterilized to avoid being transferred to other and possibly lower paying janitorial jobs or losing thier jobs completely. The company is appealing the citation. The union has also filed a complaint with the Equal Employment Opportunity Commission charging American Cyanamid with sex discrimination, since only the women workers are at risk of being transferred to lower paying jobs.

  6. Contact Lens Use in the Civil Airman Population

    National Research Council Canada - National Science Library

    Nakagawara, Van

    2002-01-01

    ...) aeromedical certificate. Although contact lens technology has advanced dramatically in recent years, the aviation environment may still have adverse effects on contact lens performance in some flight situations...

  7. Environment and the sterile insect technique

    International Nuclear Information System (INIS)

    Nagel, P.; Peveling, R.

    2005-01-01

    The sterile insect technique (SIT) is an exceptionally promising pest control method in terms of efficacy and environmental compatibility. Assessments of environmental risks vary according to the status and origin of the target pests. The suppression or eradication of exotic pest populations with the SIT raises few environmental concerns, and these are related mainly to pre-release suppression techniques. However, the elimination of native species, or at least populations of native species, requires more detailed and complex assessments of ecological effects and consequences for biodiversity conservation. Eradication programmes provide opportunities to study these topics within the scope of both environmental impact assessments and operational monitoring programmes. (author)

  8. Sterile neutrinos and B-L symmetry

    Science.gov (United States)

    Fileviez Pérez, Pavel; Murgui, Clara

    2018-02-01

    We revisit the relation between the neutrino masses and the spontaneous breaking of the B-L gauge symmetry. We discuss the main scenarios for Dirac and Majorana neutrinos and point out two simple mechanisms for neutrino masses. In this context the neutrino masses can be generated either at tree level or at quantum level and one predicts the existence of very light sterile neutrinos with masses below the eV scale. The predictions for lepton number violating processes such as μ → e and μ → eγ are discussed in detail. The impact from the cosmological constraints on the effective number of relativistic degree of freedom is investigated.

  9. Sterile searches with Liquid Argon at FNAL

    CERN Document Server

    Raselli, Gian Luca

    2017-01-01

    A new Short Baseline Neutrino (SBN) experiment is in preparation at FNAL to definitely prove or exclude the existence of non-standard neutrino oscillations into sterile states. The program foresees the deployment along the Booster Neutrino Beam (BNB) of three detectors, all based on the liquid-argon time projection chamber technique. This technology has been taken to full maturity with ICARUS T600, which will act as far detector after the completion of the overhauling at CERN and its transportation to FNAL. The program foresees the data taking for three years.

  10. Processing laboratory of radio sterilized biological tissues

    International Nuclear Information System (INIS)

    Aguirre H, Paulina; Zarate S, Herman; Silva R, Samy; Hitschfeld, Mario

    2005-01-01

    The nuclear development applications have also reached those areas related to health. The risk of getting contagious illnesses through applying biological tissues has been one of the paramount worries to be solved since infectious illnesses might be provoked by virus, fungis or bacterias coming from donors or whether they have been introduced by means of intermediate stages before the use of these tissues. Therefore it has been concluded that the tissue allografts must be sterilized. The sterilization of medical products has been one of the main applications of the ionizing radiations and that it is why the International Organization of Atomic Energy began in the 70s promoting works related to the biological tissue sterilization and pharmaceutical products. The development of different tissue preservation methods has made possible the creation of tissue banks in different countries, to deal with long-term preservation. In our country, a project was launched in 1998, 'Establishment of a Tissue Bank in Latino america', this project was supported by the OIEA through the project INT/ 6/ 049, and was the starting of the actual Processing Laboratory of Radioesterilized Biological Tissues (LPTR), leaded by the Chilean Nuclear Energy Commission (CCHEN). This first organization is part of a number of entities compounding the Tissue Bank in Chile, organizations such as the Transplantation Promotion Corporation hospitals and the LPTR. The working system is carried out by means of the interaction between the hospitals and the laboratory. The medical professionals perform the procuring of tissues in the hospitals, then send them to the LPTR where they are processed and sterilized with ionizing radiation. The cycle ends up with the tissues return released to the hospitals, where they are used, and then the result information is sent to the LPTR as a form of feedback. Up to now, human skin has been processed (64 donors), amniotic membranes (35 donors) and pig skin (175 portions

  11. Level of compliance in contact lens wearing medical doctors in Nepal.

    Science.gov (United States)

    Sapkota, Kishor

    2015-12-01

    To determine the level of compliance and major non-compliant behaviors in contact lens (CL) wearing medical doctors (MDs) and to compare it with age matched CL wearing normal subjects with no medical background (NS). Thirty-nine current CL wearing MDs, who were prescribed CLs in Nepal Eye Hospital, Kathmandu, Nepal, between 2007 and 2011, were interviewed on ten modifiable compliant behaviors regarding lens care and maintenance. The level of compliance and the rate of non-compliance for each behavior were determined and compared with NS. Level of compliance was good, average and poor in 35.9%, 48.7% and 15.4% of MDs, respectively. There was no significant difference in compliance between MDs and NS (p=0.209). Level of compliance was not associated with age, gender and duration of lens wear (p>0.05). Compliance rate varied according to different behaviors, achieving a good compliance level of 95% for hand hygiene, avoidance of water contact and not sleeping with lenses. There was poor compliance for topping up solution (53.8%) and lens case replacement (15.4%). About one third of MDs had a good level of compliance. Level of compliance and compliance rate of different behaviors were similar in MDs and NS. Periodic lens case replacement was the most neglected behavior in CL wearers for this region. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  12. Vitreous Humor Changes Expression of Iron-Handling Proteins in Lens Epithelial Cells

    Science.gov (United States)

    Goralska, Malgorzata; Fleisher, Lloyd N.; McGahan, M. Christine

    2017-01-01

    Purpose In humans, vitrectomy is associated with development of nuclear cataracts. Iron catalyzes free radical formation causing oxidative damage, which is implicated in cataract formation. This study was designed to determine if vitreous humor, which can initiate differentiation of lens epithelial cells, would have an effect on iron-handling proteins. Methods Cultured canine lens epithelial cells were treated with collected canine vitreous humor. Lysates of treated and control cells were separated by SDS-PAGE. Ferritin H- and L-chains, transferrin receptor 1, and aquaporin 0 were immunodetected and quantitated with specific antibodies. Morphologic changes in treated cells were assessed. Results Treatment of lens epithelial cells with a 33% (vol/vol) solution of vitreous humor changed the morphology of lens cells and induced expression of aquaporin 0, a marker of fiber cell differentiation that was undetectable in control cells. Treatment did not modify the size of iron-handling proteins but significantly increased content of ferritin from 2.9- to 8.8-fold over control and decreased levels of transferrin receptor by 37% to 59%. Conclusions Vitreous humor may significantly limit iron uptake by transferrin/transferrin receptor pathway, and by increasing ferritin levels could profoundly increase the iron-storage capacity of ferritin in lens cells. Vitreous humor may play a significant protective role against iron-catalyzed oxidative damage of lens epithelial cells and therefore in the formation of cataracts. PMID:28245299

  13. Corrected electrostatic lens systems for ion beams

    International Nuclear Information System (INIS)

    Dalgish, R.L.

    1981-01-01

    Recent work in our laboratory has introduced a new class of electrostatic focus forming element for beams, the ELCO lens. It compares favourably with the electrostatic and magnetic quadrupole elements conventionally used for microbeam formation. The ELCO lens does however have disadvantages associated with apertures and alignment. We have continued with the development of ion beam lenses and have evolved a further class of lens element which eliminates aperture and alignment problems. This new element can be combined like optical lenses into an aberration corrected system. Experimental measurement on the basic lens element has confirmed mathematical analysis of ion trajectories through the element. This mathematical analysis predicts that the basic element can be combined into a corrected lens system for, either: (1) high resolution microprobe formation with intrinsic rastering ability, the spot size limited only by the beam properties; or (2) high quality image formation with large magnification/demagnification ratio and wide angular aperture. (orig.)

  14. Preparation of cerium oxide for lens polishing powder

    International Nuclear Information System (INIS)

    Injarean, Uthaiwan; Rodthongkom, Chouvana; Pichestapong, Pipat; Changkrurng, Kalaya

    2003-10-01

    Cerium is an element of rare earth group which is called lanthanide series. It is found in the ores like monazite and xenotime which are the tailings of tin mines in the south of Thailand. Cerium is used mostly as lens polishing powder besides the applications in other industries. In this study, cerium extracted from monazite ore breakdown by alkaline process was used for the preparation of lens polishing powder. Cerium hydroxide cake from the process was dissolved by hydrochloric acid and precipitated with oxalic acid. The oxalate precipitate then was calcined to oxide powder and its particle size was measured. Precipitation conditions being studied are concentration of feed cerium chloride solution, concentration of oxalic acid used for the precipitation, concentration of sulfuric acid used as precipitation control reagent and the precipitation temperature. It was found that the appropriate precipitation conditions yielded the fine oxide powder with particle size about 12μm. The oxide powder can be ground to the size of 1-3 μm which is suitable for making lens polishing powder

  15. Insurgence of Fusarium keratitis associated with contact lens wear.

    Science.gov (United States)

    Alfonso, Eduardo C; Cantu-Dibildox, Jorge; Munir, Wuqaas M; Miller, Darlene; O'Brien, Terrence P; Karp, Carol L; Yoo, Sonia H; Forster, Richard K; Culbertson, William W; Donaldson, Kendall; Rodila, Jill; Lee, Yunhee

    2006-07-01

    To describe the clinical presentation and course of patients who developed keratitis due to Fusarium while wearing nontherapeutic soft contact lenses. A retrospective review of microbiologic records from January 1, 2004, through April 15, 2006, was performed, identifying all patients with corneal ulceration and a culture positive for Fusarium species. Medical records of 34 patients were reviewed for clinical characteristics, treatment regimens, and microbiologic features. The most common antimicrobial medications administered prior to Fusarium diagnosis were antibacterials in 31 of 34 patients. No distinct preponderance of any one brand of either contact lens or solution was identified. The microbiologic corneal cultures found Fusarium oxysporum in 20 cases, Fusarium solani in 3 cases, Fusarium species not further identifiable in 10 cases, and no growth in 1 case. Patients with a delayed onset of treatment had a tendency for prolonged treatment until cure. Fusarium has previously been an unusual organism in the etiology of infectious keratitis in the setting of nontherapeutic soft contact lens wear. A delay in proper diagnosis and intervention may contribute to a prolonged treatment course. The microbial spectrum of contact lens-related keratitis may be evolving with higher participation of Fusarium species compared with prior reports.

  16. Effectiveness of various sterilization methods of contaminated post-fitted molar band

    Directory of Open Access Journals (Sweden)

    Anggia Tridianti

    2013-06-01

    Full Text Available Background: Molar band as anchoring device may be contaminated during the fitting process. Thus, decontamination process is essential to prevent cross-infection between patients. Purpose: The objective of this research was to determine the amount of bacteria in molar band post-fitted on the patient teeth, after previously undergone pre-sterilization using alcohol and ultrasonic cleaning bath followed by sterilization using dry heat oven and steam autoclave, in order to find the best method in decontamination of post-fitted molar band. Methods: Four molar bands which already fitted on one patient then divided evenly into two groups. The first group was pre-sterilized using alcohol. One of the bands then sterilized using dry heat oven, while the other one was sterilized using steam autoclave. The second group was pre-sterilized using ultrasonic cleaning bath. One band from this group then sterilized using dry heat oven and the other was sterilized using steam autoclave. The next step was to immerse all the bands in a phosphate-buffered saline solution. Using micropipette, the solution was retrieved and dropped upon a petri dish containing Brain Heart Infusion broth. The dish was then stored in an incubator for 24 hours, prior to counting the number of bacteria existed. The same methods were used to the rest of the patients, with total 128 molar bands from 32 patients. Results: There was a profound difference in numbers of bacteria found between those methods of sterilization. However, there was a non significant difference between the two groups which were at the alcohol-steam autoclave group and at the ultrasonic cleaning bath-steam autoclave group. Conclusion: This study showed that steam autoclave is better than for sterilizing molar band, as it left the minimal amount of bacteria in post-fitted molar band.Latar belakang: Molar band merupakan suatu alat penjangkaran yang dapat mengalami kontaminasi selama proses fitting band, sehingga perlu

  17. American Sterilization: The Racist Justifications for Sterilization in the United States

    OpenAIRE

    Trevor Price

    2016-01-01

    An investigative analysis into anthropometrics, sterilization, eugenics, and other forms of scientific racism used to justify white supremacy and racial thought in the 19th and 20th centuries in the United States. The Tuskegee syphilis study, Darwinistic ideals, and neo-Lamarckian thoughts are critically analyzed as justifications for institutional racism.

  18. Electron sterilization validation techniques using the controlled depth of sterilization process

    International Nuclear Information System (INIS)

    Cleghorn, D.A.; Nablo, S.V.

    1990-01-01

    Many pharmaceutical products, especially parenteral drugs, cannot be sterilized with gamma rays or high energy electrons due to the concomitant product degradation. In view of the well-controlled electron energy spectrum available in modern electron processors, it is practical to deliver sterilizing doses over depths considerably less than those defining the thickness of blister-pack constructions or pharmaceutical containers. Because bremsstrahlung and X-ray production are minimized at these low electron energies and in these low Z materials, very high electron: penetrating X-ray dose ratios are possible for the application of the technique. Thin film dosimetric techniques have been developed utilizing radiochromic film in the 10-60 g/m 2 range for determining the surface dose distribution in occluded surface areas where direct electron illumination is not possible. Procedures for validation of the process using dried spore inoculum on the product as well as in good geometry are employed to determine the process lethality and its dependence on product surface geometry. Applications of the process to labile pharmaceuticals in glass and polystyrene syringes are reviewed. It has been applied to the sterilization of commercial sterile products since 1987, and the advantages and the natural limitations of the technique are discussed. (author)

  19. Reliability of laparoscopic compared with hysteroscopic sterilization at 1 year: a decision analysis.

    Science.gov (United States)

    Gariepy, Aileen M; Creinin, Mitchell D; Schwarz, Eleanor B; Smith, Kenneth J

    2011-08-01

    To estimate the probability of successful sterilization after an hysteroscopic or laparoscopic sterilization procedure. An evidence-based clinical decision analysis using a Markov model was performed to estimate the probability of a successful sterilization procedure using laparoscopic sterilization, hysteroscopic sterilization in the operating room, and hysteroscopic sterilization in the office. Procedure and follow-up testing probabilities for the model were estimated from published sources. In the base case analysis, the proportion of women having a successful sterilization procedure on the first attempt is 99% for laparoscopic sterilization, 88% for hysteroscopic sterilization in the operating room, and 87% for hysteroscopic sterilization in the office. The probability of having a successful sterilization procedure within 1 year is 99% with laparoscopic sterilization, 95% for hysteroscopic sterilization in the operating room, and 94% for hysteroscopic sterilization in the office. These estimates for hysteroscopic success include approximately 6% of women who attempt hysteroscopically but are ultimately sterilized laparoscopically. Approximately 5% of women who have a failed hysteroscopic attempt decline further sterilization attempts. Women choosing laparoscopic sterilization are more likely than those choosing hysteroscopic sterilization to have a successful sterilization procedure within 1 year. However, the risk of failed sterilization and subsequent pregnancy must be considered when choosing a method of sterilization.

  20. A study of optical design and optimization applied to lens module of laser beam shaping of advanced modern optical device

    Science.gov (United States)

    Tsai, Cheng-Mu; Fang, Yi-Chin; Chen, Zhen Hsiang

    2011-10-01

    This study used the aspheric lens to realize the laser flat-top optimization, and applied the genetic algorithm (GA) to find the optimal results. Using the characteristics of aspheric lens to obtain the optimized high quality Nd: YAG 355 waveband laser flat-top optical system, this study employed the Light tools LDS (least damped square) and the GA of artificial intelligence optimization method to determine the optimal aspheric coefficient and obtain the optimal solution. This study applied the aspheric lens with GA for the flattening of laser beams using two aspheric lenses in the aspheric surface optical system to complete 80% spot narrowing under standard deviation of 0.6142.

  1. Implante de lente intraocular en niños como solución a los problemas sociales de la ceguera por catarata congénita Intraocular lens implants for children as a solution to social problems caused by blindness from congenital cataract

    Directory of Open Access Journals (Sweden)

    Rosa María Naranjo Fernández

    2011-12-01

    congenital cataract ranges from 1 to 4 per 10 000 children in underdeveloped countries and 0,1 to 0,4 in industrialized countries. In Cuba, 2,1 million inhabitants are under 15 years of age and the congenital cataract is regarded as the second cause of infantile blindness. In the last 20 years, the surgical treatment of cataract in children has completely changed based on the remarkable improvement of the surgical techniques. In our country, the pediatric cataract surgery with intraocular lens implantation began in 1990 after the inauguration of the Ocular Microsurgery Center in 1988. The importance of this pediatric cataract surgery with intraocular lens implants was shown as a solution to the social problems caused by the visual deficit of inadequately treated patients, since the application of modern technology improves the quality of life of children both at social and educational level, and allows fully re-inserting them into the society.

  2. Study of male sterility in Taiwania cryptomerioides Hayata (Taxodiaceae).

    Science.gov (United States)

    Chen, S-H; Chung, N-J; Wang, Y-N; Lee, C-L; Lee, Y-L; Tsai, P-F

    2006-08-01

    A study of male sterility over a period of three consecutive years on a conifer species endemic to Taiwan, Taiwania cryptomerioides Hayata (Taxodiaceae), was done for this article. With the aids of fluorescence and electron microscopic observations, the ontogenic processes in the fertile and sterile microsporangia are compared, using samples collected from Chitou Experimental Forest and Yeou-Shoei-Keng Clonal Orchard of the National Taiwan University, Nantou, Taiwan. The development of male strobili occurred from August to the end of March. Microsporogenesis starts with the formation of the archesporium and ends with the maturation of 2-celled pollen grains within the dehiscing microsporangium. Before meiosis, there was no significant difference in ultrastructure between the fertile and sterile microsporangia. Asynchronous pollen development with various tetrad forms may occur in the same microsporangium of either fertile or sterile strobili. However, a callose wall was observable in the fertile dyad and tetrad, but not in the sterile one. After dissolution of the callose wall, the fertile microspores were released into the locule, while some sterile microspores still retained as tetrads or dyads with intertwining of exine walls in the proximal faces. As a result, there was no well developed lamellated endexine and no granulate ectexine or intine in the sterile microspores. Eventually, the intracellular structures in sterile microspores were dramatically collapsed before anthesis. The present study shows that the abortion in pollen development is possibly attributed to the absence of the callose wall. The importance of this structure to the male sterility of T. cryptomerioides is discussed.

  3. Genetic expression of induced rice sterility under alien-cytoplasm

    International Nuclear Information System (INIS)

    Wang Naiyuan; Cai Zhijun; Liang Kangjing; Li Yu

    2005-01-01

    Rice restorer lines were treated with 60 Co γ-ray and 4 male sterile mutants obtained with the fertility of controlled by 4 non-allelic recessive genes, respectively. Sixty combinations were made by using male sterile plants/fertile plants as male parents, and 15 different cytoplasmic substitution lines of the same cell nucleus as female parents. The result showed that F 1 spikelets were normal and fertile, and different numbers of male sterile plants were segregated in F 2 . Complete fertility genotype was not found among interactions between induced male sterile genes and alien-cytoplasms. (authors)

  4. Dark matter relic abundance and light sterile neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Yi-Lei [Center for High Energy Physics,Peking University, Beijing 100871 (China); Zhu, Shou-hua [Center for High Energy Physics,Peking University, Beijing 100871 (China); Institute of Theoretical Physics & State Key Laboratory of Nuclear Physics and Technology,Peking University, Beijing 100871 (China); Collaborative Innovation Center of Quantum Matter,Beijing 100871 (China)

    2017-01-09

    In this paper, we calculate the relic abundance of the dark matter particles when they can annihilate into sterile neutrinos with the mass ≲100 GeV in a simple model. Unlike the usual standard calculations, the sterile neutrino may fall out of the thermal equilibrium with the thermal bath before the dark matter freezes out. In such a case, if the Yukawa coupling y{sub N} between the Higgs and the sterile neutrino is small, this process gives rise to a larger Ω{sub DM}h{sup 2} so we need a larger coupling between the dark matter and the sterile neutrino for a correct relic abundance.

  5. Eugenics, sterilization, and historical memory in the United States.

    Science.gov (United States)

    Stern, Alexandra Minna

    2016-12-01

    From the 1920s to the 1950s, California sterilized approximately 20,000 people in state homes and hospitals based on a eugenic law that authorized medical superintendents to perform reproductive surgeries on patients deemed unfit and "suffering from a mental affliction likely to be inherited." Working with a unique resource - a dataset created from 19,000 sterilization recommendations - my team and I have reconstructed patterns and experiences of institutionalization of sterilizations. This article presents several of our important initial findings related to ethnic and gender bias in sterilization policies, and reflects on the relevance of the history for contemporary issues in genomics and social justice.

  6. System and method of applying energetic ions for sterilization

    Science.gov (United States)

    Schmidt, John A.

    2003-12-23

    A method of sterilization of a container is provided whereby a cold plasma is caused to be disposed near a surface to be sterilized, and the cold plasma is then subjected to a pulsed voltage differential for producing energized ions in the plasma. Those energized ions then operate to achieve spore destruction on the surface to be sterilized. Further, a system for sterilization of a container which includes a conductive or non-conductive container, a cold plasma in proximity to the container, and a high voltage source for delivering a pulsed voltage differential between an electrode and the container and across the cold plasma, is provided.

  7. ACOG Practice bulletin no. 133: benefits and risks of sterilization.

    Science.gov (United States)

    2013-02-01

    Female and male sterilization are both safe and effective methods of permanent contraception used by more than 220 million couples worldwide . Approximately 600,000 tubal occlusions and 200,000 vasectomies are performed in the United States annually . For women seeking permanent contraception, sterilization obviates the need for user-dependent contraception throughout their reproductive years and provides an excellent alternative for those with medical contraindications to reversible methods. The purpose of this document is to review the evidence for the safety and effectiveness of female sterilization in comparison with male sterilization and other forms of contraception.

  8. Sterile neutrino searches via displaced vertices at LHCb

    Science.gov (United States)

    Antusch, Stefan; Cazzato, Eros; Fischer, Oliver

    2017-11-01

    We explore the sensitivity of displaced vertex searches at LHCb for testing sterile neutrino extensions of the Standard Model towards explaining the observed neutrino masses. We derive estimates for the constraints on sterile neutrino parameters from a recently published displaced vertex search at LHCb based on run 1 data. They yield the currently most stringent limit on active-sterile neutrino mixing in the sterile neutrino mass range between 4.5 GeV and 10 GeV. Furthermore, we present forecasts for the sensitivities that could be obtained from the run 2 data and also for the high-luminosity phase of the LHC.

  9. Gene, protein and network of male sterility in rice

    Directory of Open Access Journals (Sweden)

    Wang eKun

    2013-04-01

    Full Text Available Rice is one of the most important model crop plants whose heterosis has been well exploited in commercial hybrid seed production via a variety of types of male sterile lines. Hybrid rice cultivation area is steadily expanding around the world, especially in Southern Asia. Characterization of genes and proteins related to male sterility aims to understand how and why the male sterility occurs, and which proteins are the key players for microspores abortion. Recently, a series of genes and proteins related to cytoplasmic male sterility, photoperiod sensitive male sterility, self-incompatibility and other types of microspores deterioration have been characterized through genetics or proteomics. Especially the latter, offers us a powerful and high throughput approach to discern the novel proteins involving in male-sterile pathways which may help us to breed artificial male-sterile system. This represents an alternative tool to meet the critical challenge of further development of hybrid rice. In this paper, we reviewed the recent developments in our understanding of male sterility in rice hybrid production across gene, protein and integrated network levels, and also, present a perspective on the engineering of male sterile lines for hybrid rice production.

  10. Sterilization of biological tissues with ionizing radiation

    International Nuclear Information System (INIS)

    Reyes F, M.L.; Martinez P, M.E.; Luna Z, D.

    1997-01-01

    On June 1994, the National Institute of Nuclear Research (ININ) and the South Central Hospital for High Specialty of PEMEX (HCSAE) began a joint work with the finality to obtain radio sterilized amniotic membranes for to be used as cover (biological bandage) in burnt patients. Subsequently the Chemistry Faculty of UNAM and the National Institute of Cardiology began to collaborate this last with interest on cardiac valves for graft. Starting from 1997, the International Atomic Energy Agency (IAEA) supports this project (MEX/7/008) whose main objective is to set up the basis to establish in Mexico a Radio sterilized Tissue Bank (amniotic membranes, skin, bones, tendons, cardiac valves, etc.) to be used with therapeutic purposes (grafts). The IAEA support has consisted in the equipment acquisition which is fundamental for the Tissue Bank performance such as an experimental irradiator, laminar flow bell, lyophilizer, vacuum sealer and special knives for tissues. Also visits to Mexico of experts have been authorized with the aim of advising to the personnel which participate in the project and scientific visits of this personnel to another tissue banks (Sri Lanka and Argentine). The establishment in Mexico of a Tissue bank will be a great benefit because it will have availability of distinct tissues for grafts and it will reduce the synthetic materials importation which is very expensive. (Author)

  11. Sterile Neuroinflammation and Strategies for Therapeutic Intervention

    Directory of Open Access Journals (Sweden)

    Manoj Banjara

    2017-01-01

    Full Text Available Sterile neuroinflammation is essential for the proper brain development and tissue repair. However, uncontrolled neuroinflammation plays a major role in the pathogenesis of various disease processes. The endogenous intracellular molecules so called damage-associated molecular patterns or alarmins or damage signals that are released by activated or necrotic cells are thought to play a crucial role in initiating an immune response. Sterile inflammatory response that occurs in Alzheimer’s disease (AD, Parkinson’s disease (PD, stroke, hemorrhage, epilepsy, or traumatic brain injury (TBI creates a vicious cycle of unrestrained inflammation, driving progressive neurodegeneration. Neuroinflammation is a key mechanism in the progression (e.g., AD and PD or secondary injury development (e.g., stroke, hemorrhage, stress, and TBI of multiple brain conditions. Hence, it provides an opportunity for the therapeutic intervention to prevent progressive tissue damage and loss of function. The key for developing anti-neuroinflammatory treatment is to minimize the detrimental and neurotoxic effects of inflammation while promoting the beneficial and neurotropic effects, thereby creating ideal conditions for regeneration and repair. This review outlines how inflammation is involved in the pathogenesis of major nonpathogenic neuroinflammatory conditions and discusses the complex response of glial cells to damage signals. In addition, emerging experimental anti-neuroinflammatory drug treatment strategies are discussed.

  12. Investigation of lens morphology and mechanical characteristics of lens capsule and lens nucleus in patients with agerelated and diabetic cataract

    Directory of Open Access Journals (Sweden)

    A. S. Tishkova

    2014-07-01

    Full Text Available Purpose: To investigate the influence of carbohydrate metabolism on the structure and mechanical properties of the lens capsule and nucleus.Methods: Human lens pathology was studied in different forms of cataract. 220 patients with a cataract (220 eyes were included in this study. Morphological, immunohystological and immunocytochemical investigations of lens substance (antibodies to a- (a-А and a-В, b-, g- crystallines, spectroscopic analyses of smears and morphometric analyses of slices, investigation of lens morphology and mechanical caracteristics of lens capsule and lens nucleus were performed.Results: The capsule of the lens in patients with senile cataract contains more Na+, Cl-. The capsule of the lens in patients with senile cataract contains more Ca2+, O. Mechanical strength of the capsule in the case of diabetes mellitus was lower comparatively with senile cataract in the same age groups. More significant expression of a-В and b-crystallines was found in patients with diabetes mellitus comparatively with patients with age-related cataract. Morphological features were founded in patients with cortical and nuclear forms of senile cataract and the diabetic cataract.Conclusion: During surgery (ultrasonic microcoaxial phacoemulsification the equivalent of ultrasound was recorded. Lower density of the lens nucleus of patients with diabetes mellitus made it possible to use lower energy parameters. Using the torsion ultrasound in those cases allowed us to decrease the influence of ultrasound on eye tissues and reduce the time of achieving the maximum BCVA in the postsurgical period.

  13. Investigation of lens morphology and mechanical characteristics of lens capsule and lens nucleus in patients with agerelated and diabetic cataract

    Directory of Open Access Journals (Sweden)

    A. S. Tishkova

    2013-01-01

    Full Text Available Purpose: To investigate the influence of carbohydrate metabolism on the structure and mechanical properties of the lens capsule and nucleus.Methods: Human lens pathology was studied in different forms of cataract. 220 patients with a cataract (220 eyes were included in this study. Morphological, immunohystological and immunocytochemical investigations of lens substance (antibodies to a- (a-А and a-В, b-, g- crystallines, spectroscopic analyses of smears and morphometric analyses of slices, investigation of lens morphology and mechanical caracteristics of lens capsule and lens nucleus were performed.Results: The capsule of the lens in patients with senile cataract contains more Na+, Cl-. The capsule of the lens in patients with senile cataract contains more Ca2+, O. Mechanical strength of the capsule in the case of diabetes mellitus was lower comparatively with senile cataract in the same age groups. More significant expression of a-В and b-crystallines was found in patients with diabetes mellitus comparatively with patients with age-related cataract. Morphological features were founded in patients with cortical and nuclear forms of senile cataract and the diabetic cataract.Conclusion: During surgery (ultrasonic microcoaxial phacoemulsification the equivalent of ultrasound was recorded. Lower density of the lens nucleus of patients with diabetes mellitus made it possible to use lower energy parameters. Using the torsion ultrasound in those cases allowed us to decrease the influence of ultrasound on eye tissues and reduce the time of achieving the maximum BCVA in the postsurgical period.

  14. Effect of gamma irradiation on in vitro bovine lens proteins

    International Nuclear Information System (INIS)

    Bernardes, D.M.L.; Mastro, N.L. del.

    1988-07-01

    The radiosensitivity of the ocular lens manifested by cataract formation has been of considerable interest in the study on the biological efects of radiations. Cataract can ben produced by different causes and also for the normal process of ageing. The aim of this work was to develop an in vitro system similar to in vivo cataract formation. It was used an aqueous solution of bovine lenses. The lenses after surgical removal mechanical and ultrasonic disrupted. The suspension was centrifuged and the supernatant was dialyzed and irradiated with different doses of 60 Co radiation. The opacification extent was measured in an spectrophotometer. (author) [pt

  15. Time-lens based optical packet pulse compression and retiming

    DEFF Research Database (Denmark)

    Laguardia Areal, Janaina; Hu, Hao; Palushani, Evarist

    2010-01-01

    This paper presents a new optical circuit that performs both pulse compression and frame synchronization and retiming. Our design aims at directly multiplexing several 10G Ethernet data packets (frames) to a high-speed OTDM link. This scheme is optically transparent and does not require clock...... recovery, resulting in a potentially very efficient solution. The scheme uses a time-lens, implemented through a sinusoidally driven optical phase modulation, combined with a linear dispersion element. As time-lenses are also used for pulse compression, we design the circuit also to perform pulse...

  16. Antiophidian sera sterility control: topics in perspective

    Directory of Open Access Journals (Sweden)

    Paula Gomes Santos

    2009-09-01

    Full Text Available The aim of this work is to review the most important topics about the antiophidic sera sterility, including obtaining methods, sterilization procedures and clean room control using Vital Brazil Institute (VBI as an example. Bibliographical research was performed through Medline, Lilacs, PubMed, ISI and the Fundação Oswaldo Cruz - RJ and VBI Libraries, from 1960 to 2009. The antiophidic sera for human use are immunobiologic products produced in Brazil by three national laboratories, including VBI. Due to the parenteral use, these products should be sterile and pyrogen-free, which demands the microbiological control during the whole fabrication process. The sterility and pyrogen tests are important steps to ensure the quality and safety of these immunobiological products. Thus, these tests are target for continue evaluation and improvement. The most interfering aspects in the consistency and analytical patterns include the proper method selection, sampling, culture conditions and validation criteria. As the national and international legal requirements are cautious with the assays validation and approval of sterile parenteral products; the intrinsic limitations for established assays still require more investigation aiming the continue improvement of the microorganism and contaminants detection methods and optimization of the analysis extent.O objetivo deste trabalho é revisar os tópicos mais relevantes para o controle da esterilidade de soros antiofídicos, abordando-se métodos de obtenção, procedimentos de esterilização e o controle de áreas limpas utilizando como exemplo os procedimentos adotados pelo Instituto Vital Brazil (IVB. Um levantamento bibliográfico foi realizado no Medline, ISI, Biblioteca da Fundação Oswaldo Cruz-RJ e IVB, no período de 1960 a 2009. Os soros antiofídicos para uso humano são produtos imunobiológicos fabricados no Brasil por três laboratórios nacionais, dentre eles o IVB. Por serem de administra

  17. Assessment of Color Changes in Vita 3D-Master Shade Guide after Sterilization and Disinfection

    Directory of Open Access Journals (Sweden)

    Hossein Dashti

    2017-06-01

    Full Text Available Purpose:Dental shade guides are commonly used for color determination and should be disinfected and sterilized. The purpose of this study was to evaluate the color change of Vita 3D Master shade tabs after disinfection and sterilization. Material and methods:Overall, 98 samples (shade tabs were randomly selected from 14 new, unused Vita 3D sets, including the following shades: 2M1, 3L1.5, 3M1, 3M2, 3M3, 3R1.5 and 4M1. In each set, values of 2, 3 and 4, chroma of 1, 2 and 3 and hue were selected for the comparison of different shades. All tabs were measured using the Vita Easyshade device at baseline. The first group was disinfected with Deconex and the second group was sterilized by autoclaving in a simulated annual application. All the tabs were measured again using the same device. This process was repeated to simulate 2 and 3 years of usage. Statistical analysis was conducted by repeated measures analysis of variance (ANOVA and independent t-test and paired sample t-test. Results:In the disinfected group, we observed significant differences in value and chroma in all periods (p˂0.001. However, hue showed no significant difference after the first year of simulated treatment (p=0.527, though it was significantly different in the second and third simulations (p˂0.001. In the sterilized group, all variables showed a significant difference for each year (p˂0.05. Considering total color difference (ΔE, there was a significant difference between the two groups in the first, second and third simulated years; ΔE increased in the sterilized group more than in the disinfected samples (p˂0.001.  Conclusions:  The color change of shade tabs was significant both after disinfection by a chemical solution and by sterilization through autoclaving. However, although disinfectants may not have a clinically important effect, sterilization should be considered as an interfering factor during color-matching procedure.

  18. Why are rates of sterilization in decline? A pilot study designed to explore reasons for declining female sterilization in Scotland.

    Science.gov (United States)

    Chen, Zhong E; Glasier, Anna; Warner, Pamela

    2008-10-01

    In the last decade, female sterilization had been in decline throughout the UK. It is not clear whether fewer women are requesting sterilization or whether the universal enthusiasm for long-acting reversible methods is leading health professionals to discourage women from being sterilized. Since correct and consistent use of alternative, reversible contraceptive methods depends somewhat on their acceptability, it is important to determine whether women are being refused sterilization or whether they are freely choosing other methods. This study aims to explore whether female sterilization is being widely considered as a contraceptive method, the reasons for choosing or rejecting it, and whether women are being discouraged by health professionals from being sterilized. A self-completed questionnaire survey among 205 women aged 30 to 50 years who felt that their family was complete attending a family planning clinic in Scotland. Of the 203 women included in the study, 151 (74.4%) had heard of female sterilization, 90 had discussed it with someone (60%) and 87 (58%) had considered it as a contraceptive option. Of the 56 women who consulted their family doctor about sterilization, almost half (27; 48%) were not referred to a hospital and fewer than one (17, 30.4%) in three of them was eventually sterilized or had arrangements in place to get it done. Free-text comments from the women revealed a variety of reasons for not choosing female sterilization and suggested that some women are being deterred from sterilization. The study suggests that some women are being actively encouraged by health professionals to use long-acting reversible contraceptive methods and discouraged from choosing sterilization. However, other women recognize for themselves the wisdom of keeping their fertility options open.

  19. Concurrent acanthamoeba and Fusarium keratitis with silicone hydrogel contact lens use.

    Science.gov (United States)

    Lee, Barry; Grossniklaus, Hans E; Edelhauser, Henry F

    2010-02-01

    To report a case of simultaneous Acanthamoeba and Fusarium keratitis associated with no-rub multipurpose contact lens solution and silicone hydrogel contact lens use. Observational case report. A 39-year-old woman was referred for worsening of a presumed bacterial corneal ulcer in the setting of silicone hydrogellens wear with occasional overnight wear, no-rub multipurpose contact lens solution use, and combined topical antibiotic/corticosteroid treatment. Initial corneal scrapings and culture confirmed Acanthamoeba and Fusarium solani, corroborated by in vivo confocal microscopy findings, yet despite topical chlorhexidine 0.02%, propamidine 1%,neomycin/polymyxin B ointment, and natamycin 5% along with oral itraconazole, the ulcer worsened. Four days after amoebic and fungal therapy initiation, it was discovered that the pharmacy accidentally dispensed neomycin/polymyxin B/dexamethasone, and despite immediate discontinuation, therapeutic penetrating keratoplasty from corneal melting was ultimately required. Corneal histopathology confirmed the presence of amoebic cysts and fungal elements. Coexisting infection with Acanthamoeba and Fusarium species can occur in contact lens wear. Atypical infection must be considered in patients with corneal ulcers demonstrating poor therapeutic response in the setting of contact lens wear. Corticosteroids should be used with extreme caution in contact lens–related corneal infections, especially when the diagnosis remains unknown because they can lead to acceleration of active infection and keratolysis.

  20. Cuba Through A New Lens

    Directory of Open Access Journals (Sweden)

    Jean Stubbs

    2008-12-01

    Full Text Available [First paragraph] The Origins of the Cuban Revolution Reconsidered. Samuel Farber. Chapel Hill: University of North Carolina Press, 2006. x + 212 pp. (Paper US$ 19.95 Cuba: A New History. Ric hard Gott . New Haven: Yale University Press, 2005. xii + 384 pp. (Paper US$ 17.00 Havana: The Making of Cuban Culture. Antoni Kapcia. Oxford: Berg Publishers, 2005. xx + 236 pp. (Paper US$ 24.95 Richard Gott, Antoni Kapcia, and Samuel Farber each approach Cuba through a new lens. Gott does so by providing a broad-sweep history of Cuba, which is epic in scope, attaches importance to social as much as political and economic history, and blends scholarship with flair. Kapcia homes in on Havana as the locus for Cuban culture, whereby cultural history becomes the trope for exploring not only the city but also Cuban national identity. Farber revisits his own and others’ interpretations of the origins of the Cuban Revolution.

  1. THE ROLE OF THE HYPOTHALAMUS LESIONS IN WOMEN'S STERILITY - AN EXPERIMENTAL STUDY

    Directory of Open Access Journals (Sweden)

    Vladmila Bojanic

    2001-01-01

    Full Text Available The anovulatory cycles and amenorrhea in the female patients with Cushing'ssyndrome, coupled with sterility, the Cushingoid type of obesity in our experiment as well as contradictory data about sterility of rats and mice in the identical experimentrepresent the reasons for studyng the function and morphology of the ovaries in theanimals treated by monosodium glutamate (MSG.The experimental group of the black mice C57BL/6.T of the female gender hasbeen treated by an intraperitoneal solution of MSG in the dose of 4,4 mg/g of the bodyweightfrom the first to the ninth day after birth. The coupling of the treated femaleswith the untreated males was done after 90 days of age; these females were sacrificed120 days after birth. The ovaries were removed and fixed in the solution of 10%fonnaldehyde, manually treated and cut on the microtone. The paraffin sections werecolored by HE, PAS and Van Giesen methods. The identical procedure was alsoappliced to the control group of animals of both sexes.All the treated animals were sterile. The ovaries were enlarged, cystic, withoutyellow or albinic bodies. In the control females, there were Graf follicles found invarious phases of maturation as well as luteinized stroma.The paper discusses the disturbance of the hypothalamus-hypophysis-gonadaxis caused by the damage of the hypothalamus regions secreting various "releasing"hormones.

  2. Fertility and reproductive history of sterilized and non-sterilized women in Campinas, São Paulo, Brazil

    Directory of Open Access Journals (Sweden)

    Maria José Duarte Osis

    Full Text Available This article compares sterilized and non-sterilized women in relation to socio-demographic characteristics, reproductive history, and cohabitation status. Women from 30 to 49 years of age and residing in Campinas, São Paulo State, Brazil, were interviewed with a pre-tested and structured questionnaire: 236 women sterilized at least five years before the interview and 236 non-sterilized women. The sterilized women were significantly more likely to be married or cohabiting, to be younger when they began cohabiting, and to have been in the union longer than the non-sterilized women. They also began childbearing at an earlier age and had a history of more pregnancies and more live births than non-sterilized women. Factors associated with a history of 3 or more live births at the time of the interview were surgical sterilization, younger age at first childbirth, older age at the interview, recognition of fewer contraceptive methods, and lower per capita income. The article concludes that sterilization generally appears to be the consequence of higher fertility in a group of women who initiate childbearing early in life, although its role in preventing these women from having even larger families may also have a demographic impact.

  3. The role of Serratia marcescens in soft contact lens associated ocular infections. A review.

    Science.gov (United States)

    Parment, P A

    1997-02-01

    Serratia marcescens is a Gram negative rod which for a century and a half was considered a harmless saphrophyte. However, medical technology and the use of antibacterial agents have created ecological niches for this bacterium, which is now a medical problem. The bacterium is encountered in connection with contact lens keratitis, often associated with contaminated contact lens solutions. The concentrations of chlorhexidin and thiomersal required in contact lens solution to suppress the bacterium have been proved toxic to the eye. Modern contact lens solutions with biguanids have rapid killing kinetics, while in solutions with polyquaternium S. marcescens can survive in reduced numbers for up to 72 hours. The adherence of a specific isolate of Serratia to hydrogel lenses increased with decreased water content of the lenses. However, there has been no correlation between hydrophobicity markers or hemagglutinins and adherence to contact lenses or urinary tract epithelium. When handling medical plastic devices, such as contact lenses, strictly enforced hygiene remains the most important method to combat environmental bacteria such as Serratia marcescens.

  4. Combined analysis of the binary lens caustic-crossing event MACHO 98-SMC-1

    NARCIS (Netherlands)

    Afonso, C; Alard, C; Albert, JN; Andersen, J; Ansari, R; Aubourg, E; Bareyre, P; Bauer, F; Beaulieu, JP; Bouquet, A; Char, S; Charlot, [No Value; Couchot, F; Coutures, C; Derue, F; Ferlet, R; Glicenstein, JF; Goldman, B; Gould, A; Graff, D; Gros, M; Haissinski, J; Hamilton, JC; Hardin, D; de Kat, J; Kim, A; Lasserre, T; Lesquoy, E; Loup, C; Magneville, C; Marquette, JB; Maurice, E; Milsztajn, A; Moniez, M; Palanque-Delabrouille, N; Perdereau, O; Prevot, L; Regnault, N; Rich, J; Spiro, M; Vidal-Madjar, A; Vigroux, L; Zylberajch, S; Alcock, C; Allsman, RA; Alves, D; Axelrod, TS; Becker, AC; Cook, KH; Drake, AJ; Freeman, KC; Griest, K; King, LJ; Lehner, MJ; Marshall, SL; Minniti, D; Peterson, BA; Pratt, MR; Quinn, PJ; Rodgers, AW; Stetson, PB; Stubbs, CW; Sutherland, W; Tomaney, A; Vandehei, T; Rhie, SH; Bennett, DP; Fragile, PC; Johnson, BR; Quinn, J; Udalski, A; Kubiak, M; Szymanski, M; Pietrzynski, G; Wozniak, P; Zebrun, K; Albrow, MD; Caldwell, JAR; DePoy, DL; Dominik, M; Gaudi, BS; Greenhill, J; Hill, K; Kane, S; Martin, R; Menzies, J; Pogge, RW; Pollard, KR; Sackett, PD; Sahu, KC; Vermaak, P; Watson, R; Williams, A

    2000-01-01

    We fit the data for the binary lens microlensing event MACHO 98-SMC-1 from five different microlensing collaborations and find two distinct solutions characterized by binary separation d and mass ratio q: (d, q) = (0.54, 0.50) and (d, q) = (3.65, 0.36), where d is in units of the Einstein radius.

  5. Utilization of methanol in crude glycerol to assist lipid production in non-sterilized fermentation from Trichosporon oleaginosus.

    Science.gov (United States)

    Chen, Jiaxin; Zhang, Xiaolei; Tyagi, Rajeshwar Dayal; Drogui, Patrick

    2018-04-01

    In this work, methanol in crude glycerol solution was used to assist the lipid production with oleaginous yeast Trichosporon oleaginosus cultivated under non-sterilized conditions. The investigated methanol concentration was 0%, 1.4%, 2.2%, 3.3% and 4.4% (w/v). The results showed that methanol played a significant role in the non-sterilized fermentation for lipid production. The optimal methanol concentration was around 1.4% (w/v) in which the growth of T. oleaginosus was promoted and overcame that of the contaminants. The non-sterilized fed-batch fermentation with initial methanol concentration of 1.4% (w/v) was then performed and high biomass production (43.39 g/L) and lipid production (20.42 g/L) were achieved. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Effectiveness of different methods of preparing seedlings of cereals under sterile conditions for investigations of nucleic acids using radioactive precursors

    Directory of Open Access Journals (Sweden)

    W. Filek

    2015-01-01

    Full Text Available On seedlings grown from grain not sterilized in advance bacteria numbered more than 108 microorganisms per one gram of fresh weight. Washing of seedlings with cetyltrimethylammonium bromide or sodium lauryl sulphate solutions reduced the number of bacteria several times. Sterilization of grains prior to planting with sodium hypochlorite and germination on solid substratum (perlit reduced the number of bacteria to below 104 microorganisms to one gram of fresh weight. If germination was, however, in water, bacteria on the seedlings were approximately as numerous as on seedlings from mon-sterilized grains. Of the three antibiotics tested (streptomycin, chloramphenicol, penicillin the most effective against the bacteria of wheat seedlings was chloramphenicol coupled with streptomycin; of antibiotics used singly chloramphenicol was best.

  7. Sterilization of fruit flies (Diptera: Tephritidae) with X-rays for sterile insect technique programs

    International Nuclear Information System (INIS)

    Mastrangelo, Thiago de Araujo

    2009-01-01

    Recent fear of acts of terrorism provoked an increase of delays and denials in the shipment of radioisotopes. This truly represented a menace to sterile insect production projects around the world. In order to validate the use of a new kind of low-energy Xray irradiator, a series of radiobiological studies on Ceratitis capitata (tsl-VIENNA 8 strain) (Wied., 1824) (Diptera: Tephritidae) and an Argentinean strain of Anastrepha fraterculus (Wied., 1830) (Diptera: Tephritidae) were carried out, also comparing biological effectiveness between X-rays and traditional γ radiation from 60 Co. Pupae 48- 24 h before adult emergence of C. capitata males and both sexes of A. fraterculus were irradiated with doses ranging from 15 to 120 Gy and 10 to 70 Gy respectively. Doses that induce 50, 90 and 99% of sterility were estimated and the hypothesis of Parallelism for the Probit equations was tested. Doses of 82.7 Gy of X-rays and 128.2 Gy of γ rays (thus, a RBE∼1.5) induced 99% sterility on medfly males. The fertility of A. fraterculus fertile females crossed with 41 Gy of X-rays and 62.7 Gy of γ rays decreased in 99% comparing with the control group (RBE∼1.5). 99% sterility of A. fraterculus irradiated females was achieved with 60-80 Gy (RBE∼0.7). The standard quality control parameters of fecundity, adult emergence, fliers and survival were not significantly affected by the two types of radiation (RBE∼1) either for medfly or A. fraterculus (p>0.01), being averages in conformity with the values required by FAO/IAEA/USDA. Only fecundity of irradiated A. fraterculus females was severely reduced with increasing doses and no egg was laid at 70 Gy of both radiations. There were no significant differences between X-rays and γ rays regarding mating indices (RSI for medfly, RII, ISI, MRPI and FRPI for A. fraterculus) (p>0.05), what indicated more random matings for fertile and sterile insects. The results demonstrated that no significant difference in biological

  8. Contraceptive sterilization among Canadians, 1984-1995

    Directory of Open Access Journals (Sweden)

    Krishnan, Vijaya

    2004-01-01

    Full Text Available EnglishPrior to early 1970s, traditional methods were the principal means ofcontrolling the number and spacing of births. Today, an estimated 57 per cent of the world's marriedwomen use contraceptives and half use modern methods such as medical sterilizations. Recent statisticssuggest that Canada has the highest sterilization rate in the Western world. This paper presentsfindings of research examining sterilization trends in Canada with respect to changing patterns in theuse of modern contraceptives, using data from the 1984 Canadian Fertility Survey (CFS and the 1995General Social Survey (GSS. The main finding is that there is a decrease in the use of tubal ligationand an increase in the use of hysterectomy over the period 1984-1995. Less educated women are morelikely to be in the forefront of modern methdos of contraception.FrenchAvant les années 1970, les méthodes traditionnelles représentaient le principalmoyen de contrôler et d’espacer le nombre de naissances. De nos jours, onestime que 57 pour cent des femmes mariées dans le monde entier utilisent unmoyen contraceptif et la moitié utilise des méthodes modernes telles que lastérilisation. Les dernières statistiques indiquent que le Canada compte le tauxde stérilisations le plus élevé dans le monde occidental. Cet article présente lesconclusions de recherches portant sur les tendances en matière de stérilisation auCanada en ce qui concerne les modèles changeants d’utilisation de moyens decontraception modernes et ce, à partir de données de l’Enquête canadienne sur lafécondité de 1984 et de l’Enquête sociale générale (ESG de 1995. La principaleconclusion qui en est ressortie est une réduction de la ligature des trompes etune augmentation du nombre d’hystérectomies de 1984 à 1995. Les femmesmoins éduquées sont plus portées à se trouver au premier plan des méthodes decontraception modernes.

  9. History of the sterile insect technique

    International Nuclear Information System (INIS)

    Klassen, W.; Curtis, C.F.

    2005-01-01

    During the 1930s and 1940s the idea of releasing insects of pest species to introduce sterility (sterile insect technique or SIT) into wild populations, and thus control them, was independently conceived in three extremely diverse intellectual environments. The key researchers were A. S. Serebrovskii at Moscow State University, F. L. Vanderplank at a tsetse field research station in rural Tanganyika (now Tanzania), and E. F. Knipling of the United States Department of Agriculture. Serebrovskii's work on chromosomal translocations for pest population suppression could not succeed in the catastrophic conditions in the USSR during World War II, after which he died. Vanderplank used hybrid sterility to suppress a tsetse population in a large field experiment, but lacked the resources to develop this method further. Knipling and his team exploited H. J. Muller's discovery that ionizing radiation can induce dominant lethal mutations, and after World War II this approach was applied on an area-wide basis to eradicate the New World screwworm Cochliomyia hominivorax (Coquerel) in the USA, Mexico, and Central America. Since then very effective programmes integrating the SIT have been mounted against tropical fruit flies, some species of tsetse flies Glossina spp., the pink bollworm Pectinophora gossypiella (Saunders), and the codling moth Cydia pomonella (L.). In non-isolated onion fields in the Netherlands, the onion maggot Delia antiqua (Meigen) has since 1981 been suppressed by the SIT. In the 1970s there was much research conducted on mosquito SIT, which then went into 'eclipse', but now appears to be reviving. Development of the SIT for use against the boll weevil Anthonomus grandis grandis Boheman and the gypsy moth Lymantria dispar (L.) has ended, but it is in progress for two sweetpotato weevil species, Cylas formicarius (F.) and Euscepes postfasciatus (Fairmaire), the false codling moth Cryptophlebia leucotreta (Meyrick), the carob moth Ectomyelois ceratoniae

  10. Influence of sterilization on the mineralization of titanium implants induced by incubation in various biological model fluids.

    Science.gov (United States)

    Serro, A P; Saramago, B

    2003-11-01

    The aim of this work was to investigate the effect of the sterilization processes on the mineralization of titanium implants induced by incubation in various biological model fluids. Titanium samples were submitted to the following sterilization processes used for implant materials: steam autoclaving, glow discharge Ar plasma treatment and gamma-irradiation. The modification of the treated surfaces was evaluated by contact angle determinations, X-ray photoelectron spectroscopy (XPS), laser profilometry and X-ray diffraction. The most significant modifications were detected on the wettability: while the samples treated with Ar plasma became highly hydrophilic (water contact angle approximately 0 degrees), gamma-irradiation and steam sterilization induced an increase in the hydrophobicity. After being sterilized, the samples were incubated for one week in three biological model fluids: Hanks' Balanced Salt Solution, Kokubo's simulated body fluid (SBF) and a fluid, designated by SBF0, with the same composition of SBF but without buffer TRIS. The level of mineralization of the incubated Ti samples, assessed by dynamic contact angle analysis, scanning electron microscopy, electron dispersive spectroscopy and XPS, indicated that the early stages of mineralization are essentially independent of the sterilization method. In contrast, the incubating fluid plays a determinant role, SBFO being the most efficient medium for biomineralization of titanium.

  11. A study on the spreading ability of radiation-sterilized male moth of bombyx mandarin in field

    International Nuclear Information System (INIS)

    Yang Rongxin; Xia Darong; Gu Weiping; Zhang Yanjun

    1998-01-01

    The mulberry wild silkworm (MWS), belong to the Bombycidae of Lepidoptera, is serious pest of sericulture. The female moth of MWS is sterile and the male moth is sub-sterile when they were treated with 250 Gy 60 Co γ-ray (dose rate: 1.05 Gy/min), and their filial generations was sterile. The spreading ability of male moth of MWS in field and retrieving the marked MWS male moth with the trapping method was studied. The trapping solution was composed of sugar, vinegar, wine and alive female moth. The retrieving rate of MWS male moth amounted to 12.6%∼13.5% of released moth in field. The spreading range in 24 hours for sterile MWS male moth reached to 700 m, and 90.8% of MWS male moth was in an area of 5 m radius from the releasing centre. It is concluded that thirty releasing centres per hectare are needed to make the irradiated sterilized insects spread for controlling the MWS in field

  12. [Survey of methods of cleaning, decontamination, disinfection and sterilization in dental health services in tropical areas].

    Science.gov (United States)

    Clapeau, G; Decroix, B; Bakayoko-Ly, R; Varenne, B; Dosso-Hien, D; Decroix, M O

    1997-01-01

    The International Aid for Ontology (IAO) carried out this survey of hygiene in the dental health services of 5 French-speaking African countries in 1994, in association with the Faculty of Pharmaceutical and Biological Sciences of Paris. This study received support from the World Health Organization (WHO), the French Ministry for Cooperation and the European Community and the Ivory Coast Oral and Dental Hygiene and Health Committee (CIHSBD). Twenty-nine dental services from Benin (3), Burkina Faso (6), Ivory Coast (12), Mali (5), Niger (3) participated in this survey which gives an insight into the daily hygiene routines of these services. The cleaning, decontamination, disinfection and sterilization procedures for premises, dental equipment, instruments, hands and disposable items were investigated. No individual protocols are reported. Bench tops were cleaned or disinfected daily in 73% of centers and floors were cleaned or disinfected daily in 59% of centers. Walls were cleaned once per week in 44% of the centers. Hands were always washed between patients, with 68% of dental surgeons using only solid or liquid cleansing soaps and the others using antiseptic or disinfectant solutions. The dentist's chair was cleaned or disinfected daily in 68% of centers, mostly with soap (43%) or diluted bleach (23%). Vacuum equipment was cleaned with soap (50%) or diluted bleach (57%), with some surgeries using a combination of the two. Hand pieces and turbines were cleaned and disinfected after each use with alcohol (35%) or diluted bleach (26%) and were sterilized in 9% of centers. Instruments were sterilized with a Poupinel (63%), unspecified sterilizer (26%), autoclave (7%) or low temperature disinfection procedure (4%). Instruments were regularly sterilized in all centers. Single-use disposable items were often reused: 88% of centers reused gloves, 64% anesthetic cartridges and 32% disposable needles. This survey demonstrates that dentists do attempt to achieve appropriate

  13. 9. School of radiation sterilization and hygienization - Lectures

    International Nuclear Information System (INIS)

    Zimek, Z.; Kaluska, I.; Gluszewski, W.

    2007-01-01

    During the 9 School of radiation sterilization and hygienization 23 lectures were presented. They were devoted to all aspects of sterilization and hygienization of food, medicinal articles and cosmetics using the ionisation radiation. It was destined to physicians, manufacturers and vendees of spices, pharmaceuticals and cosmetics, personnel of the sanitary-epidemiological stations and even for the art conservators

  14. Assessing genetic variability in male sterile and low fertile citrus ...

    African Journals Online (AJOL)

    Understanding phylogenetic relationships and genetic diversity in citrus are important in clarifying genetic relationships, characterizing germplasm and the registration of new cultivars. In this study, the genetic diversity of 28 accessions of citrus including male sterile, sterile, low fertile and fertile cultivars were investigated ...

  15. Assessment of Non-Sterile Pharmaceutical Compounding Practices ...

    African Journals Online (AJOL)

    A descriptive cross-sectional survey was conducted to assess the practices of non-sterile pharmaceutical compounding in selected 42 community and 3 hospital pharmacies in Addis Ababa, Ethiopia from 01 April, 2016 to 15 May, 2016. The study revealed that the most commonly prescribed and compounded non-sterile ...

  16. Tracking the expression of photosensitive genic male sterility genes ...

    African Journals Online (AJOL)

    Photoperiod sensitive genic male sterile rice lines contain genes that induce complete sterility in high temperature and long day light length period, and revert to fertility in optimum low temperature and short day light length period. These lines are good candidates for hybrid rice seed production. The main challenge limiting ...

  17. An alternative safer and cost effective surface sterilization method for ...

    African Journals Online (AJOL)

    Regardless of its serious health effect, mercury chloride is frequently utilized for surface sterilization to mitigate microbial contamination in sugarcane tissue culture. The current study aimed at finding an alternative safer and cost effective sterilization method to substitute mercury chloride. In the study, sugarcane shoot tip ...

  18. Effect of sterilization on mineralization of straw and black carbon

    DEFF Research Database (Denmark)

    Bobul'ská, Lenka; Bruun, Sander; Fazekašová, Danica

    2013-01-01

    The study was aimed at investigating the role of microorganisms in the degradation of BC (black carbon). CO evolution was measured under sterilized and non-sterilized soil using BC and straw amendments. Black carbon and straw were produced from homogenously C labelled roots of barley (Hordeum vul...... abiotic source must also be present perhaps abiotic mineralization of labile BC components....

  19. 9. School of radiation sterilization and hygienization - Presentations

    International Nuclear Information System (INIS)

    Zimek, Z.; Kaluska, I.; Gluszewski, W.

    2007-01-01

    During the 9. School of radiation sterilization and hygienization 23 lectures were presented. They were devoted to all aspects of sterilization and hygienization of food, medicinal articles and cosmetics using the ionisation radiation. It was destined to physicians, manufacturers and vendees of spices, pharmaceuticals and cosmetics, personnel of the sanitary-epidemiological stations and even for the art conservators

  20. The context and limitations of female sterilization services in Pakistan.

    Science.gov (United States)

    Khan, Adnan Ahmad; Khan, Ayesha; Abbas, Khadija; Tirmizi, Syed Farhan Ali; ul Islam, Zia

    2013-04-01

    Female sterilization has long been the most popular method of family planning (FP) in Pakistan, and yet most public health experts feel it contributes little to controlling family size or to population welfare. We used Pakistan Demographic Health Survey (PDHS) data to understand the role female sterilization plays in the overall context of FP in Pakistan. We performed a secondary analysis of data from the PDHS 1990-1 and 2006-7 to study factors that lead to sterilization and trends in the use of the procedure. In addition, census data were multiplied by proportions from PDHS data to estimate the number of women availing sterilization services. Around 1.9 million women in Pakistan are currently sterilized--up from 0.55 million in 1990-1, and around 173,867 undergo the procedure, annually. Women usually receive sterilization after 30 years of age (mean = 39) and after six children. The probability of sterilization increases with age, family size, and urban residence, and is unaffected by poverty, province of residence, or the woman or her husband's education. Most sterilizationis conducted in public sector facilities. Sterilization in Pakistan may be common, but occurs too late to have any significant effect on family size or benefit public health. Future avenues to make this option more useful to women and society would be to improve the repertoire and access and quality of FP services that are available, and to address governance issues that limit the performance and utility of government facilities.

  1. 42 CFR 50.207 - Sterilization by hysterectomy.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Sterilization by hysterectomy. 50.207 Section 50.207 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS POLICIES OF GENERAL APPLICABILITY Sterilization of Persons in Federally Assisted Family Planning Projects § 50.207...

  2. Hysteroscopic tubal sterilization: a systematic review of the Essure system

    DEFF Research Database (Denmark)

    Hurskainen, Ritva; Hovi, Sirpa-Liisa; Gissler, Mika

    2010-01-01

    sterilization, but more information on the total cost is needed. CONCLUSION(S): The Essure system appears to be safe, permanent, irreversible, and a less invasive method of contraception compared with laparoscopic sterilization. Copyright (c) 2010 American Society for Reproductive Medicine. Published...... by Elsevier Inc. All rights reserved....

  3. Comparison of Sterile and Clean Dressing Techniques in Post ...

    African Journals Online (AJOL)

    Comparison of Sterile and Clean Dressing Techniques in Post-operative Surgical Wound Infection in a Chinese Healthcare Facility. ... of sterile and clean dressing techniques on wound management in a Chinese hospital, and to compare their impact on wound healing and the cost of the dressing materials with respect to ...

  4. Female sterilization by tubal ligation at caesarean section in Makurdi ...

    African Journals Online (AJOL)

    Background: Female sterilization is an important tool in reducing unplanned pregnancy and maternal mortality in our environment. The aim of this study was to determine the incidence, sociodemographic characteristics, technique, effectiveness and complications associated with female sterilization by bilateral tubal ligation ...

  5. Puzzles in modern biology. I. Male sterility, failure reveals design.

    Science.gov (United States)

    Frank, Steven A

    2016-01-01

    Many human males produce dysfunctional sperm. Various plants frequently abort pollen. Hybrid matings often produce sterile males. Widespread male sterility is puzzling. Natural selection prunes reproductive failure. Puzzling failure implies something that we do not understand about how organisms are designed. Solving the puzzle reveals the hidden processes of design.

  6. Thermalisation of light sterile neutrinos in the early universe

    DEFF Research Database (Denmark)

    Hannestad, Steen; Tamborra, Irene; Tram, Thomas

    2012-01-01

    on the current cosmological data have been derived using simplified assumptions about thermalisation of the sterile neutrino at the Big Bang Nucleosynthesis (BBN) epoch. These assumptions are not necessarily justified and here we solve the full quantum kinetic equations in the (1 active + 1 sterile) scenario...

  7. Surface sterilization method for reducing microbial contamination of ...

    African Journals Online (AJOL)

    An effective disinfection method for strawberry (Fragaria x ananassa Duch.) cv. Senga Sengana micropropagation using runner tips and nodal segments as explants was developed. The explants were surface sterilized with different sterilants for different durations. The present studies on the effect of different regimes of ...

  8. Sterilization by Minilaparotomy in South-Eastern Nigeria | Nwogu ...

    African Journals Online (AJOL)

    The study aimed to assess the trend in acceptance and characteristics of acceptors of female sterilization between January 1999 and December 2006 at the University of Nigeria Teaching Hospital, Enugu, South-Eastern Nigeria. There were a total of 20,485 new clients, with 212 (1.0%) accepting sterilization between ...

  9. 7 CFR 305.28 - Kiln sterilization treatment schedule.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 5 2010-01-01 2010-01-01 false Kiln sterilization treatment schedule. 305.28 Section 305.28 Agriculture Regulations of the Department of Agriculture (Continued) ANIMAL AND PLANT HEALTH... sterilization treatment schedule. T404-b-4 Dry bulb temperature( °F) Wet bulb depression( °F) Percent...

  10. Sterilization of the Mentally Ill and the Mentally Retarded.

    Science.gov (United States)

    National Association of State Mental Health Program Directors, Washington, DC.

    Reported were the results of a survey on the sterilization of the mentally ill and the mentally retarded. Thirty-three states responded to the survey. It was found that 17 states have a sterilization statute, but the existence of the statute was explained not to mean that the procedure was used. Sixteen states responded that they did not have a…

  11. An alternative safer and cost effective surface sterilization method for ...

    African Journals Online (AJOL)

    user

    2013-10-30

    Oct 30, 2013 ... Regardless of its serious health effect, mercury chloride is frequently utilized for surface sterilization to mitigate microbial contamination in sugarcane tissue culture. The current study aimed at finding an alternative safer and cost effective sterilization method to substitute mercury chloride. In the study,.

  12. Efficacy in Microbial Sterilization of Pulsed Magnetic Field Treatment

    Science.gov (United States)

    Sterilization effects of the pulsed magnetic field with a maximum intensity of 11.37 Tesla were investigated on Escherichia coli AS 1.129, Staphylococcus aureus AS 1.89, Saccharomyces cerevisiae ATTC 7552 and Bacillus subtilis AS 1.921. The well-regulated fluctuations of sterilization effects with m...

  13. Vitrification of human pronuclear oocytes by direct plunging into cooling agent: Non sterile liquid nitrogen vs. sterile liquid air.

    Science.gov (United States)

    Isachenko, Vladimir; Todorov, Plamen; Seisenbayeva, Akerke; Toishibekov, Yerzhan; Isachenko, Evgenia; Rahimi, Gohar; Mallmann, Peter; Foth, Dolores; Merzenich, Markus

    2018-02-01

    In fact, a full sterilization of commercially-produced liquid nitrogen contaminated with different pathogens is not possible. The aim of this study was to compare the viability of human pronuclear oocytes subjected to cooling by direct submerging of open carrier in liquid nitrogen versus submerging in clean liquid air (aseptic system). One- and three-pronuclei stage embryos (n = 444) were cryopreserved by direct plunging into liquid nitrogen (vitrified) in ethylene glycol (15%), dimethylsulphoxide (15%) and 0.2M sucrose. Oocytes were exposed in 20, 33, 50 and 100% vitrification solution for 2, 1 and 1 min, and 30-50 s, respectively at room temperature. Then first part of oocytes (n = 225) were directly plunged into liquid nitrogen, and second part of oocytes (n = 219) into liquid air. Oocytes were thawed rapidly at a speed of 20,000 °C/min and then subsequently were placed into a graded series of sucrose solutions (0.5, 0.25, 0.12 and 0.06M) at 2.5 min intervals and cultured in vitro for 3 days. In both groups, the rate of high-quality embryos (Grade 6A: 6 blastomeres, no fragmentation; Grade 8A: 8 blastomeres, no fragmentation; Grade 8A compacting: 8 blastomeres, beginning of compacting) was noted. The rates of high-quality embryos developed from one-pronuclear oocytes vitrified by cooling in liquid nitrogen and liquid air were: 39.4% ± 0.6 and 38.7% ± 0.8, respectively (P > 0.1). These rates for three-pronuclear oocytes were: 45.8 ± 0.8% and 52.0 ± 0.7%, respectively (P liquid air (aseptic system) is a good alternative for using of not sterile liquid nitrogen. Copyright © 2017. Published by Elsevier Inc.

  14. Radiation effects on polypropylene for sterilization.

    Science.gov (United States)

    Khang, G; Lee, H B; Park, J B

    1996-01-01

    In order to improve the resistance of gamma-radiation sterilization of polypropylene (PP), the formulations of the additives such as antioxidants, crosslinking agent, and trans-stilbene oxide (StO) have been carried out. The irradiated PP and ethylene-propylene copolymer samples with control and additives were characterized by mechanical tester, colorimetry, and Fourier transform infrared spectroscopy with total attenuated reflectance mode (FTIR-ATR). Crosslinking agent and StO formulated PP showed remarkable radiation resistance and minimum discoloration. Also, radiation resistance of ethylene-propylene copolymers with 3% of ethylene contents was better than that of PP homopolymers in the case of no additives. The proposed mechanisms of radiation stabilization with additives are also discussed.

  15. Sterile neutrinos and B–L symmetry

    Directory of Open Access Journals (Sweden)

    Pavel Fileviez Pérez

    2018-02-01

    Full Text Available We revisit the relation between the neutrino masses and the spontaneous breaking of the B–L gauge symmetry. We discuss the main scenarios for Dirac and Majorana neutrinos and point out two simple mechanisms for neutrino masses. In this context the neutrino masses can be generated either at tree level or at quantum level and one predicts the existence of very light sterile neutrinos with masses below the eV scale. The predictions for lepton number violating processes such as μ→e and μ→eγ are discussed in detail. The impact from the cosmological constraints on the effective number of relativistic degree of freedom is investigated.

  16. [The psychosocial background of sterile patients].

    Science.gov (United States)

    Pusch, H H; Urdl, W; Walcher, W

    1989-01-01

    The psychosocial background of 300 childless couples from the Infertility Clinic of the Department of Gynecology and Obstetrics, University of Graz, was evaluated by means of a questionnaire and statistical analysis of data from their files. Points of special interest were problems such as interactions of the couple, motivations for the desire of children, psychosomatics, andrological investigation within the gynecological department, sexual habits and motivation and compliance concerning investigations and treatment. 72% of the questionnaires were returned. 50% of the sterile couples preferred to attend the infertility clinic together. 26% felt restrictions in their sexual behaviour due to the unrealized desire of children, 48% expected improvements in their partnership if they could have children. Compliance of male partners concerning the regular intake of prescribed medicaments was 83%, 63% accepted to stop smoking in cases of pathospermia.

  17. Neutrophil Responses to Sterile Implant Materials.

    Directory of Open Access Journals (Sweden)

    Siddharth Jhunjhunwala

    Full Text Available In vivo implantation of sterile materials and devices results in a foreign body immune response leading to fibrosis of implanted material. Neutrophils, one of the first immune cells to be recruited to implantation sites, have been suggested to contribute to the establishment of the inflammatory microenvironment that initiates the fibrotic response. However, the precise numbers and roles of neutrophils in response to implanted devices remains unclear. Using a mouse model of peritoneal microcapsule implantation, we show 30-500 fold increased neutrophil presence in the peritoneal exudates in response to implants. We demonstrate that these neutrophils secrete increased amounts of a variety of inflammatory cytokines and chemokines. Further, we observe that they participate in the foreign body response through the formation of neutrophil extracellular traps (NETs on implant surfaces. Our results provide new insight into neutrophil function during a foreign body response to peritoneal implants which has implications for the development of biologically compatible medical devices.

  18. Heavy Sterile Neutrino in Dark Matter Searches

    Directory of Open Access Journals (Sweden)

    Paraskevi C. Divari

    2018-01-01

    Full Text Available Sterile neutrinos are possible dark matter candidates. We examine here possible detection mechanisms, assuming that the neutrino has a mass of about 50 keV and couples to the ordinary neutrino. Even though this neutrino is quite heavy, it is nonrelativistic with a maximum kinetic energy of 0.1 eV. Thus new experimental techniques are required for its detection. We estimate the expected event rate in the following cases: (i measuring electron recoil in the case of materials with very low electron binding; (ii low temperature crystal bolometers; (iii spin induced atomic excitations at very low temperatures, leading to a characteristic photon spectrum; (iv observation of resonances in antineutrino absorption by a nucleus undergoing electron capture; (v neutrino induced electron events beyond the end point energy of beta decaying systems, for example, in the tritium decay studied by KATRIN.

  19. Radiation treatment for sterilization of packaging materials

    International Nuclear Information System (INIS)

    Haji-Saeid, Mohammad; Sampa, Maria Helena O.; Chmielewski, Andrzej G.

    2007-01-01

    Treatment with gamma and electron radiation is becoming a common process for the sterilization of packages, mostly made of natural or synthetic plastics, used in the aseptic processing of foods and pharmaceuticals. The effect of irradiation on these materials is crucial for packaging engineering to understand the effects of these new treatments. Packaging material may be irradiated either prior to or after filling. The irradiation prior to filling is usually chosen for dairy products, processed food, beverages, pharmaceutical, and medical device industries in the United States, Europe, and Canada. Radiation effects on packaging material properties still need further investigation. This paper summarizes the work done by different groups and discusses recent developments in regulations and testing procedures in the field of packaging technology

  20. Contact lens compliance among a group of young, university-based lens users in South India.

    Science.gov (United States)

    Noushad, Babu; Saoji, Yeshwant; Bhakat, Premjit; Thomas, Jyothi

    2012-01-01

    To investigate the rate of compliance with the soft contact lens care and maintenance procedures with a focus on contact lens wearing habits, cleaning and disinfecting procedures, and maintenance of lens care accessories in a group of young, university-based contact lens wearers Two hundred and sixteen young soft contact lens wearers with an age range of 18-22 years were selected conveniently from the student population of Manipal University, Manipal, India. After receiving informed consent from the participants, their level of compliance with contact lenses was assessed using a questionnaire. The mean (±SD) age of the participants was 21.86±2.35 years. Out of 216 subjects, only 34% of the lens users were identified to be compliant with the least level of compliance observed in the maintenance of lens care accessories. Conventional users showed significantly (p=0.001) better level of compliance compared to disposable wearers and so did the users who acquired their lenses from clinicians (p=0.001) compared to over-the-counter lens receipt. The gender (p=0.496) and years of experience in contact lens use (p=0.142) did not show any statistically significant difference in the level of compliance. This study demonstrated that non-compliance with lens care procedures among a group of young, university-based soft contact lens wearers is common. The results indicated that all subjects had some degree of non-compliance and the least level of compliance observed in the care of lens accessories.

  1. Radiation sterilized bone response to dynamic loading

    Energy Technology Data Exchange (ETDEWEB)

    Mardas, Marcin, E-mail: marcin.mardas@skpp.edu.pl [Department of Oncology, Poznan University of Medical Sciences, ul. Szamarzewskiego 82/84, 60-569 Poznan (Poland); Kubisz, Leszek [Department of Biophysics, Poznan University of Medical Sciences, ul. Fredry 10, 61-701 Poznan (Poland); Biskupski, Piotr; Mielcarek, Slawomir [Department of Physics, Adam Mickiewicz University, ul. Umultowska 85, 61-614 Poznan (Poland); Stelmach-Mardas, Marta [Department of Bromatology, Poznan University of Medical Sciences, ul. Marcelinska 420, 60-354 Poznan (Poland); Kaluska, Iwona [Centre for Radiation Research and Technology, Institute of Nuclear Chemistry and Technology, ul. Dorodna 16, 03-195 Warsaw (Poland)

    2012-08-01

    Allogeneic bone grafts are used on a large scale in surgeries. To avoid the risk of infectious diseases, allografts should be radiation-sterilized. So far, no international consensus has been achieved regarding the optimal radiation dose. Many authors suggest that bone sterilization deteriorates bone mechanical properties. However, no data on the influence of ionizing radiation on bone dynamic mechanical properties are available. Bovine femurs from 2-year old animal were machine cut and irradiated with the doses 10, 15, 25, 35, 45 and 50 kGy. Dynamic mechanical analysis was performed at 1-10 Hz at the temperature range of 0-350 Degree-Sign C in 3-point bending configuration. No statistically significant differences in storage modulus were observed. However, there were significant decreased values of loss modulus between the samples irradiated with doses of 10 ({down_arrow}14.3%), 15, 45 and 50 kGy ({down_arrow}33.2%) and controls. It was stated that increased irradiation dose decreases the temperature where collagen denaturation process starts and increases the temperature where the collagen denaturation process finishes. It was shown that activation energy of denaturation process is significantly higher for the samples irradiated with the dose of 50 kGy (615 kJ/mol) in comparison with control samples and irradiation with other doses (100-135 kJ/mol). - Highlights: Black-Right-Pointing-Pointer We examine changes in the storage modulus and loss modulus of samples irradiated with doses of 10-50 kGy. Black-Right-Pointing-Pointer We examine changes in the denaturation temperature of samples irradiated with doses of 10-50 kGy. Black-Right-Pointing-Pointer We examine changes in the activation energy of denaturation process of samples irradiated with doses of 10-50 kGy.

  2. Mechanisms of urinary tract sterility maintenance

    Directory of Open Access Journals (Sweden)

    Emilia Okrągła

    2014-06-01

    Full Text Available Physiologically, urine and the urinary tract are maintained sterile because of physical and chemical properties of urine and the innate immune system’s action. The urinary tract is constantly exposed to the invasion of microorganisms from the exterior environment, also because of the anatomical placement of the urethra, in the vicinity of the rectum. Particularly vulnerable to urinary tract infections (UTI are women (an additional risk factor is pregnancy, but also the elderly and children. The main pathogens causing UTI are bacteria; in 70-95% of cases it is the bacterium Escherichia coli. Infections caused by viruses and fungi are less common and are associated with decreased immunity, pharmacotherapy, or some diseases. Bacteria have evolved a number of factors that facilitate the colonization of the urinary tract: the cover and cell membrane antigens O and K1, lipopolysaccharide (LPS, fimbriae, pile and cilia. On the other hand, the human organism has evolved mechanisms to hinder colonization of the urinary tract: mechanisms arising from the anatomical structure of the urinary tract, the physicochemical properties of the urine and the activity of the innate immune system, also known as non-specific, which isolates and destroys pathogens using immunological processes, and the mechanisms for release of antimicrobial substances such as Tamm-Horsfall protein, mucopolysaccharides, immunoglobulins IgA and IgG, lactoferrin, lipocalin, neutrophils, cytokines and antimicrobial peptides. This review aims to analyze the state of knowledge on the mechanisms to maintain the sterility of the urinary tract used by the human organism and bacterial virulence factors to facilitate the colonization of the urinary tract.

  3. Post-sterilization autonomy among young mothers in South India.

    Science.gov (United States)

    Pallikadavath, Saseendran; Rajan, Irudaya; Singh, Abhishek; Ogollah, Reuben; Page, Samantha

    2015-01-01

    This study examined the post-sterilization autonomy of women in south India in the context of early sterilization and low fertility. Quantitative data were taken from the third round of the National Family Health Survey (NFHS-3) carried out in 2005-06, and qualitative data from one village each in Kerala and Tamil Nadu during 2010-11. The incident rate ratios and thematic analysis showed that among currently married women under the age of 30 years, those who had been sterilized had significantly higher autonomy in household decision-making and freedom of mobility compared with women who had never used any modern family planning method. Early age at sterilization and low fertility enables women to achieve the social status that is generally attained at later stages in the life-cycle. Policies to capitalize on women's autonomy and free time resulting from early sterilization and low fertility should be adopted in south India.

  4. Color stability of shade guides after autoclave sterilization.

    Science.gov (United States)

    Schmeling, Max; Sartori, Neimar; Monteiro, Sylvio; Baratieri, Luiz

    2014-01-01

    This study evaluated the influence of 120 autoclave sterilization cycles on the color stability of two commercial shade guides (Vita Classical and Vita System 3D-Master). The specimens were evaluated by spectrophotometer before and after the sterilization cycles. The color was described using the three-dimensional CIELab system. The statistical analysis was performed in three chromaticity coordinates, before and after sterilization cycles, using the paired samples t test. All specimens became darker after autoclave sterilization cycles. However, specimens of Vita Classical became redder, while those of the Vita System 3D-Master became more yellow. Repeated cycles of autoclave sterilization caused statistically significant changes in the color coordinates of the two shade guides. However, these differences are considered clinically acceptable.

  5. Development of ozone sterilization system based microcontroller for E. Coli bacteria sterilization

    Science.gov (United States)

    Eko Fahrudin, Arfan; Endarko; Vijai Nasrulloh, Amar; Sari, Nurma

    2017-05-01

    It has been created microcontroller-based ozone sterilization system which is used for E. Coli bacteria sterilization. The created system consists of a neon sign transformer, corona electrode, ozone gas chamber container and ozone gas metering systems. Neon sign transformer and corona electrode are then assembled into an ozone generator that works on the principle of corona discharge. The use of ozone generators is controlled by microcontroller system. Ozone gas is produced by ozone generators which housed in a chamber and equipped by ozone gas indicator. The results of ozone gas effect testing in E. Coli with varied exposure of 15, 30 and 45 minutes showed the decrease number of E. Coli colonies of tested bacteria samples compared to the control sample without ozone gas exposure.

  6. Placement of a crystalline lens and intraocular lens: Retinal image quality.

    Science.gov (United States)

    Siedlecki, Damian; Nowak, Jerzy; Zajac, Marek

    2006-01-01

    The influence of changes of both crystalline lens and intraocular lens (IOL) misalignment on the retinal image quality was investigated. The optical model of the eye used in investigations was the Liou-Brennan model, which is commonly considered as one of the most anatomically accurate. The original crystalline lens from this model was replaced with an IOL, made of rigid polymethylmethacrylate, in a way that recommend obligatory procedures. The modifications that were made both for crystalline lens and IOL were the longitudinal, the transversal, and the angular displacement.

  7. Restoring lens capsule integrity enhances lens regeneration in New Zealand albino rabbits and cats.

    Science.gov (United States)

    Gwon, A; Gruber, L J; Mantras, C

    1993-11-01

    In studies conducted by numerous investigators for 150 years, lenses regenerated following endocapsular lens extraction in New Zealand albino rabbits have been irregular in shape, appearing primarily doughnut-shaped as a result of lack of lens growth at the site of the anterior capsulotomy and its adhesion to the posterior capsule. In the present study, we restored the lens capsule integrity by inserting a collagen patch at the time of surgery to seal the anterior capsulotomy and to improve the shape and structure of the regenerated lenses. We then filled the capsule bag with air to prevent adhesions between the anterior and posterior capsule and maintain capsule tautness and shape. Lens regeneration was first noted as early as one to two weeks. Regenerated lens filled approximately 50% of the capsule bag at two weeks and 100% by five weeks. Subsequent growth was in the anterior-posterior direction and measured by A-scan biometry. Lens thickness increased by 0.3 mm per month. The regenerated lenses were spherical with normal cortical structure and a nuclear opacity. In conclusion, restoration of lens capsular integrity with a collagen patch following endocapsular lens extraction enhanced the shape, structure, and growth rate of the regenerated lenses. In addition, lens regeneration was shown to occur in two cats.

  8. Development of Fresnel lens for improvement of rear visibility; Shikai kojo Fresnel lens no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Iwamoto, K.; Sanada, C.; Tsukino, M. [Nissan Motor Co. Ltd., Tokyo (Japan)

    1997-10-01

    Fresnel lenses have been widely used to increase the visual field around vehicles for drivers. However, internal reflection in these lenses has been an obstacle in producing dear images. This internal glow is generated by incident light from an unexpected direction reflecting on the non-lens surface or radiating from the non-lens surface of the Fresnel lens. The cause of internal glow has been made dear combining louver film with the lens. The newly developed technology removes obstacles in producing dear images by reducing internal glow. 7 figs.

  9. Night Vision Goggles Objectives Lens Focusing Methodology

    National Research Council Canada - National Science Library

    Pinkus, Alan; Task, H. L

    2000-01-01

    ...: interpupillary distance, tilt, eye relief, height, eyepiece and objective lens focus. Currently, aircrew use a Hoffman 20/20 test unit to pre-focus their NVG objective lenses at optical infinity before boarding their aircraft...

  10. Role of Aquaporin 0 in lens biomechanics

    Energy Technology Data Exchange (ETDEWEB)

    Sindhu Kumari, S.; Gupta, Neha [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); Shiels, Alan [Washington University School of Medicine, St. Louis, MO (United States); FitzGerald, Paul G. [Cell Biology and Human Anatomy, School of Medicine, University of California, Davis, CA (United States); Menon, Anil G. [University of Cincinnati College of Medicine, Cincinnati, OH (United States); Mathias, Richard T. [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States); Varadaraj, Kulandaiappan, E-mail: kulandaiappan.varadaraj@stonybrook.edu [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States)

    2015-07-10

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5{sup −/−}), AQP0 KO (heterozygous KO: AQP0{sup +/−}; homozygous KO: AQP0{sup −/−}; all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0{sup +/−} lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and

  11. Impact of moth suppression/eradication programmes using the sterile insect technique or inherited sterility

    International Nuclear Information System (INIS)

    Bloem, K.A.; Bloem, S.; Carpenter, J.E.

    2005-01-01

    Numerous lepidopteran species have been investigated as candidates for control using the sterile insect technique (SIT) or inherited sterility (IS). However to date only two programmes are operational - the pink bollworm containment programme in the San Joaquin Valley, California, USA, and the codling moth suppression programme in British Columbia, Canada. Both of these programmes have been highly successful in controlling the pest populations, reducing insecticide use, and improving interactions between growers and the general public. However, other benefits, including the positive economic impacts of these programmes, have not been fully quantified. Methods to reduce the cost of lepidopteran programmes might include combining the SIT/IS with other pest control tactics such as mating disruption or the release of natural enemies, the development of genetic sexing strains, or the application of molecular technologies to develop genetic markers and genetic sterility. In future the greatest potential for impact of lepidopteran SIT/IS programmes may be in combating key invasive threats such as the eradication of an outbreak of the painted apple moth in New Zealand. (author)

  12. Evolution and the Calcite Eye Lens

    OpenAIRE

    Williams, Vernon L.

    2013-01-01

    Calcite is a uniaxial, birefringent crystal, which in its optically transparent form, has been used for animal eye lenses, the trilobite being one such animal. Because of the calcite birefringence there is a difficulty in using calcite as a lens. When the propagation direction of incoming light is not exactly on the c-axis, the mages blur. In this paper, calcite blurring is evaluated, and the non-blurring by a crystallin eye lens is compared to a calcite one.

  13. Acute lens-induced glaucomas: A review

    Directory of Open Access Journals (Sweden)

    Syed Shoeb Ahmad

    2017-02-01

    Full Text Available Lens-induced factors are important and common mechanisms causing acute elevation of intraocular pressure. While in most cases, the diagnosis and management are straight-forward, in others it is difficult and can lead to improper procedures, complications and poor visual outcomes. This review was done with the aim of studying the various types of lens-induced glaucomas, classifying them in an easy way to understand manner, their clinical features, current management and future possibilities.

  14. Polymicrobial Infection of the Cornea Due to Contact Lens Wear

    Directory of Open Access Journals (Sweden)

    Selçuk Sızmaz

    2016-04-01

    Full Text Available A 38-year-old male presented with pain and redness in his left eye. He had a history of wearing contact lenses. His ophthalmic examination revealed a large corneal ulcer with surrounding infiltrate. Cultures were isolated from the contact lenses, lens solutions, storage cases, and conjunctivae of both eyes and also corneal scrapings of the left eye. Fortified vancomycin and amikacin drops were started hourly. Culture results of conjunctivae of each eye and left cornea were positive for Pseudomonas aeruginosa; cultures from the contact lenses, lens solution and storage case of both eyes revealed Pseudomonas aeruginosa and Alcaligenes xylosoxidans. Polymerase chain reaction of the corneal scraping was positive for Acanthameoba. The topical antibiotics were changed with ones that both bacteria were sensitive to and anti-amoebic therapy was added. The patient had two recurrences following initial presentation despite intensive therapy. Keratitis occurred due to multiple pathogens; the relapsing course despite adequate therapy is potentially associated with this polymicrobial etiology.

  15. 21 CFR 522.1610 - Oleate sodium solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oleate sodium solution. 522.1610 Section 522.1610 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Oleate sodium solution. (a) Specifications. Each milliliter of sterile aqueous solution contains 50...

  16. 21 CFR 524.1044a - Gentamicin ophthalmic solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Gentamicin ophthalmic solution. 524.1044a Section... § 524.1044a Gentamicin ophthalmic solution. (a) Specifications. Each milliliter of sterile aqueous solution contains gentamicin sulfate equivalent to 3 milligrams of gentamicin. (b) Sponsor. See No. 000061...

  17. 21 CFR 178.1005 - Hydrogen peroxide solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Hydrogen peroxide solution. 178.1005 Section 178... SANITIZERS Substances Utilized To Control the Growth of Microorganisms § 178.1005 Hydrogen peroxide solution. Hydrogen peroxide solution identified in this section may be safely used to sterilize polymeric food...

  18. 21 CFR 529.50 - Amikacin sulfate intrauterine solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Amikacin sulfate intrauterine solution. 529.50 Section 529.50 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Amikacin sulfate intrauterine solution. (a) Specifications. Each milliliter of sterile aqueous solution...

  19. Steady-State Diffusion of Water through Soft-Contact LensMaterials

    Energy Technology Data Exchange (ETDEWEB)

    Fornasiero, Francesco; Krull, Florian; Radke, Clayton J.; Prausnitz, JohnM.

    2005-01-31

    Water transport through soft contact lenses (SCL) is important for acceptable performance on the human eye. Chemical-potential gradient-driven diffusion rates of water through soft-contact-lens materials are measured with an evaporation-cell technique. Water is evaporated from the bottom surface of a lens membrane by impinging air at controlled flow rate and humidity. The resulting weight loss of a water reservoir covering the top surface of the contact-lens material is recorded as a function of time. New results are reported for a conventional hydrogel material (SofLens{trademark} One Day, hilafilcon A, water content at saturation W{sub 10} = 70 weight %) and a silicone hydrogel material (PureVision{trademark}, balafilcon A, W{sub 10} = 36 %), with and without surface oxygen plasma treatment. Also, previously reported data for a conventional HEMA-SCL (W{sub 10} = 38 %) hydrogel are reexamined and compared with those for SofLens{trademark} One Day and PureVision{trademark} hydrogels. Measured steady-state water fluxes are largest for SofLens{trademark} One Day, followed by PureVision{trademark} and HEMA. In some cases, the measured steady-state water fluxes increase with rising relative air humidity. This increase, due to an apparent mass-transfer resistance at the surface (trapping skinning), is associated with formation of a glassy skin at the air/membrane interface when the relative humidity is below 55-75%. Steady-state water-fluxes are interpreted through an extended Maxwell-Stefan diffusion model for a mixture of species starkly different in size. Thermodynamic nonideality is considered through Flory-Rehner polymer-solution theory. Shrinking/swelling is self-consistently modeled by conservation of the total polymer mass. Fitted Maxwell-Stefan diffusivities increase significantly with water concentration in the contact lens.

  20. The TFOS International Workshop on Contact Lens Discomfort: report of the subcommittee on neurobiology.

    Science.gov (United States)

    Stapleton, Fiona; Marfurt, Carl; Golebiowski, Blanka; Rosenblatt, Mark; Bereiter, David; Begley, Carolyn; Dartt, Darlene; Gallar, Juana; Belmonte, Carlos; Hamrah, Pedram; Willcox, Mark

    2013-10-18

    This report characterizes the neurobiology of the ocular surface and highlights relevant mechanisms that may underpin contact lens-related discomfort. While there is limited evidence for the mechanisms involved in contact lens-related discomfort, neurobiological mechanisms in dry eye disease, the inflammatory pathway, the effect of hyperosmolarity on ocular surface nociceptors, and subsequent sensory processing of ocular pain and discomfort have been at least partly elucidated and are presented herein to provide insight in this new arena. The stimulus to the ocular surface from a contact lens is likely to be complex and multifactorial, including components of osmolarity, solution effects, desiccation, thermal effects, inflammation, friction, and mechanical stimulation. Sensory input will arise from stimulation of the lid margin, palpebral and bulbar conjunctiva, and the cornea.