WorldWideScience

Sample records for lens reflex camera

  1. Temperature characterization of a radiating gas layer using digital-single-lens-reflex-camera-based two-color ratio pyrometry.

    Science.gov (United States)

    Deep, Sneh; Krishna, Yedhu; Jagadeesh, Gopalan

    2017-10-20

    The two-color ratio pyrometry technique using a digital single-lens reflex camera has been used to measure the time-averaged and path-integrated temperature distribution in the radiating shock layer in a high-enthalpy flow. A 70 mm diameter cylindrical body with a 70 mm long spike was placed in a hypersonic shock tunnel, and the region behind the shock layer was investigated. The systematic error due to contributions from line emissions was corrected by monitoring the emission spectrum from this region using a spectrometer. The relative contributions due to line emissions on R, G, and B channels of the camera were 7.4%, 2.2%, and 0.4%, respectively. The temperature contours obtained clearly distinguished regions of highest temperature. The maximum absolute temperature obtained in the experiment was ∼2920  K±55  K, which was 20% lower than the stagnation temperature. This lower value is expected due to line-of-sight integration, time averaging, and losses in the flow. Strategies to overcome these limitations are also suggested in the paper.

  2. Margin Reflex Distance: Differences Based on Camera and Flash Positions.

    Science.gov (United States)

    Choi, Catherine J; Chou, Jonathan C; Lefebvre, Daniel R; Yoon, Michael K

    2016-01-01

    To evaluate the effect of camera flash position on the measurement of photographic margin reflex distances (MRD). Subjects without any ophthalmic disease were prospectively enrolled after institutional review board approval. Clinical measurements of MRD1 and interpalpebral fissure were obtained. Photographs were then taken with a digital single lens reflex with built-in pop-up flash (dSLR-pop), a dSLR with lens-mounted ring flash (dSLR-ring), a point-and-shoot camera, and a smartphone, each in 4 positions: with the camera upright, rotated 90°, 180°, and 270°. The images were analyzed using ImageJ software to measure MRD1, interpalpebral fissure, horizontal white-to-white, and distance from nasal limbus to the corneal light reflex. Thirty-two eyes of 16 subjects were included (ages 27-65). When using the dSLR-ring, point-and-shoot, and smartphone, the difference between clinical and photographic MRD1 did not reach statistical significance. There was, however, a statistically significant difference in the upright position with dSLR-pop (mean difference 0.703 mm, σ = 0.984 mm, p = 0.0008). For dSLR-pop, photographic MRD1 in upright versus inverted position differed significantly (mean difference -0.562 mm, σ =0.348 mm, p MRD1 between dSLR-pop and dSLR-ring showed significant difference in upright position (mean difference -0.572 mm, σ = 0.701 mm, p = 0.0002). There were no statistically significant differences between clinical and photographic interpalpebral fissure, and among white-to-white and nasal limbus to light reflex measurements in any position in all 4 cameras. When using photographs for measurement of MRD1, cameras with a near-coaxial light source and aperture have values that are most similar to clinical measurements.

  3. Photographic zoom fisheye lens design for DSLR cameras

    Science.gov (United States)

    Yan, Yufeng; Sasian, Jose

    2017-09-01

    Photographic fisheye lenses with fixed focal length for cameras with different sensor formats have been well developed for decades. However, photographic fisheye lenses with variable focal length are rare on the market due in part to the greater design difficulty. This paper presents a large aperture zoom fisheye lens for DSLR cameras that produces both circular and diagonal fisheye imaging for 35-mm sensors and diagonal fisheye imaging for APS-C sensors. The history and optical characteristics of fisheye lenses are briefly reviewed. Then, a 9.2- to 16.1-mm F/2.8 to F/3.5 zoom fisheye lens design is presented, including the design approach and aberration control. Image quality and tolerance performance analysis for this lens are also presented.

  4. Decision Support System to Choose Digital Single Lens Camera with Simple Additive Weighting Method

    Directory of Open Access Journals (Sweden)

    Tri Pina Putri

    2016-11-01

    Full Text Available One of the technologies that evolve today is Digital Single Lens Reflex (DSLR camera. The number of products makes users have difficulties to choose the appropriate camera based on their criteria. Users may utilize several ways to help them choosing the intended camera such as using magazine, internet, and other media. This paper discusses about a web based decision support system to choose cameras by using SAW (Simple Additive Weighting method in order to make the decision process more effective and efficient. This system is expected to give recommendations about the camera which is appropriate with the user’s need and criteria based on the cost, the resolution, the feature, the ISO, and the censor. The system was implemented by using PHP and MySQL. Based on the result of questionnaire distributed to 20 respondents, 60% respondents agree that this decision support system can help users to choose the appropriate camera DSLR in accordance with the user’s need, 60% of respondents agree that this decision support system is more effective to choose DSLR camera and 75% of respondents agree that this system is more efficient. In addition, 60.55% of respondents agree that this system has met 5 Es Usability Framework.

  5. Portraiture lens concept in a mobile phone camera

    Science.gov (United States)

    Sheil, Conor J.; Goncharov, Alexander V.

    2017-11-01

    A small form-factor lens was designed for the purpose of portraiture photography, the size of which allows use within smartphone casing. The current general requirement of mobile cameras having good all-round performance results in a typical, familiar, many-element design. Such designs have little room for improvement, in terms of the available degrees of freedom and highly-demanding target metrics such as low f-number and wide field of view. However, the specific application of the current portraiture lens relaxed the requirement of an all-round high-performing lens, allowing improvement of certain aspects at the expense of others. With a main emphasis on reducing depth of field (DoF), the current design takes advantage of the simple geometrical relationship between DoF and pupil diameter. The system has a large aperture, while a reasonable f-number gives a relatively large focal length, requiring a catadioptric lens design with double ray path; hence, field of view is reduced. Compared to typical mobile lenses, the large diameter reduces depth of field by a factor of four.

  6. Analysing responses to climate change through the lens of reflexivity.

    Science.gov (United States)

    Davidson, Debra

    2012-12-01

    Sociologists are increasingly directing attention toward social responses to climate change. As is true of any new field of inquiry, theoretical frameworks guiding the research to date have room for improvement. One advance could be achieved through closer engagement with Reflexivity Theory, particularly the work of Margaret Archer, who asks just how individuals come to give attention to certain problems, and formulate responses to them. Individuals vary significantly in regard to their understanding of and concern for anthropogenic climate change, and these standpoints in turn influence commitment to mitigation and adaptation. The emergent social interactions among all such agents in turn influence the morphogenetic trajectories through which social structures will evolve, but the role of 'meta-reflexives' is particularly crucial. Identifying pathways of individual climate change reflexivity can make a valuable contribution to our understanding of the potential for and nature of collective responses. In this paper, I explore climate change reflexivity, with particular attention to climate change meta-reflexives, through a qualitative analysis of personal interviews with residents of two small communities in Alberta, Canada. Applying Reflexivity Theory to this context articulates dimensions of reflexive processing not elaborated in current theoretical treatments, including future outlook and comfort with uncertainty, among others. © London School of Economics and Political Science 2012.

  7. Evaluation of optimized digital fundus reflex photographs for lens opacities in the age-related eye disease study 2: AREDS2 report 7.

    Science.gov (United States)

    Domalpally, Amitha; Danis, Ronald P; Chew, Emily Y; Clemons, Traci E; Reed, Susan; Sangiovanni, John Paul; Ferris, Frederick L

    2013-09-05

    We described the system for grading lens opacities using stereoscopic digital fundus reflex photographs in the Age-Related Eye Disease Study 2 (AREDS2) and compared reproducibility with the AREDS lens grading system, which used retroillumination film images. Stereoscopic fundus reflex photographs were acquired in a standardized fashion at baseline and annually. Images were enhanced and evaluated in the red channel at a central reading center. Percentage involvement of cortical and posterior subcapsular (PSC) lens opacities within the central 5 mm diameter zone of a modified AREDS lens grid was estimated. Reproducibility was assessed for contemporaneous variability (ongoing, monthly regrade on 5% of submissions, n = 777 eyes) and temporal drift (regrading a subset of baseline photographs annually, n = 88). In the contemporaneous exercise, the agreement for presence of cortical opacities was 93% (κ = 0.86) and for PSC opacities it was 97% (κ = 0.83). Intraclass correlation (ICC) for area of central zone involvement was 0.95 for cortical and 0.99 for PSC opacities. Historic data for contemporaneous regrading of film-based images in AREDS showed an ICC of 0.94 for cortical and 0.82 for PSC. The final annual temporal drift exercise had a reproducibility of 95% for cortical and PSC opacities. Digital grading using fundus reflex images with image enhancing tools has reproducibility comparable to film-based retroillumination images, and may be useful for centralized objective lens opacity assessment in clinical trials using widely available fundus cameras. Red reflex images limit evaluation to cortical and PSC opacities, and do not permit assessment of nuclear opacities. (ClinicalTrials.gov number, NCT00345176.).

  8. A little-known 3-lens Catadioptric Camera by Bernard Schmidt

    Science.gov (United States)

    Busch, Wolfgang; Ceragioli, Roger C.; Stephani, Walter

    2013-07-01

    The authors investigate a prototype 3-lens f/1 catadioptric camera, built in 1934 by the famous optician Bernhard Schmidt at the Hamburg-Bergedorf Observatory in Germany, where Schmidt worked before his death in 1935. The prototype is in the observatory's collection of Schmidt artifacts, but its nature was not understood before the authors' recent examination. It is an astronomical camera of a form known as 'Buchroeder-Houghton', consisting of a spherical mirror and a 3-element afocal corrector lens placed at the mirror's center of curvature. The design is named for R.A. Buchroeder and J.L. Houghton who independently published this and related forms of wide-field spherical-lens cameras after 1942. Schmidt died before he could publish his own design. The authors disassembled the prototype and measured its optical parameters. These they present together with a transmission test of the corrector lens. The authors also consider the theoretical performance of the design as built, the theory of Houghton cameras, Schmidt's possible path to his invention, and the place of the prototype in his scientific output.

  9. Geometric calibration of lens and filter distortions for multispectral filter-wheel cameras.

    Science.gov (United States)

    Brauers, Johannes; Aach, Til

    2011-02-01

    High-fidelity color image acquisition with a multispectral camera utilizes optical filters to separate the visible electromagnetic spectrum into several passbands. This is often realized with a computer-controlled filter wheel, where each position is equipped with an optical bandpass filter. For each filter wheel position, a grayscale image is acquired and the passbands are finally combined to a multispectral image. However, the different optical properties and non-coplanar alignment of the filters cause image aberrations since the optical path is slightly different for each filter wheel position. As in a normal camera system, the lens causes additional wavelength-dependent image distortions called chromatic aberrations. When transforming the multispectral image with these aberrations into an RGB image, color fringes appear, and the image exhibits a pincushion or barrel distortion. In this paper, we address both the distortions caused by the lens and by the filters. Based on a physical model of the bandpass filters, we show that the aberrations caused by the filters can be modeled by displaced image planes. The lens distortions are modeled by an extended pinhole camera model, which results in a remaining mean calibration error of only 0.07 pixels. Using an absolute calibration target, we then geometrically calibrate each passband and compensate for both lens and filter distortions simultaneously. We show that both types of aberrations can be compensated and present detailed results on the remaining calibration errors.

  10. INVESTIGATION OF PARALLAX ISSUES FOR MULTI-LENS MULTISPECTRAL CAMERA BAND CO-REGISTRATION

    Directory of Open Access Journals (Sweden)

    J. P. Jhan

    2017-08-01

    Full Text Available The multi-lens multispectral cameras (MSCs, such as Micasense Rededge and Parrot Sequoia, can record multispectral information by each separated lenses. With their lightweight and small size, which making they are more suitable for mounting on an Unmanned Aerial System (UAS to collect high spatial images for vegetation investigation. However, due to the multi-sensor geometry of multi-lens structure induces significant band misregistration effects in original image, performing band co-registration is necessary in order to obtain accurate spectral information. A robust and adaptive band-to-band image transform (RABBIT is proposed to perform band co-registration of multi-lens MSCs. First is to obtain the camera rig information from camera system calibration, and utilizes the calibrated results for performing image transformation and lens distortion correction. Since the calibration uncertainty leads to different amount of systematic errors, the last step is to optimize the results in order to acquire a better co-registration accuracy. Due to the potential issues of parallax that will cause significant band misregistration effects when images are closer to the targets, four datasets thus acquired from Rededge and Sequoia were applied to evaluate the performance of RABBIT, including aerial and close-range imagery. From the results of aerial images, it shows that RABBIT can achieve sub-pixel accuracy level that is suitable for the band co-registration purpose of any multi-lens MSC. In addition, the results of close-range images also has same performance, if we focus on the band co-registration on specific target for 3D modelling, or when the target has equal distance to the camera.

  11. Low-Cost Mobile Phone Microscopy with a Reversed Mobile Phone Camera Lens

    Science.gov (United States)

    Fletcher, Daniel A.

    2014-01-01

    The increasing capabilities and ubiquity of mobile phones and their associated digital cameras offer the possibility of extending low-cost, portable diagnostic microscopy to underserved and low-resource areas. However, mobile phone microscopes created by adding magnifying optics to the phone's camera module have been unable to make use of the full image sensor due to the specialized design of the embedded camera lens, exacerbating the tradeoff between resolution and field of view inherent to optical systems. This tradeoff is acutely felt for diagnostic applications, where the speed and cost of image-based diagnosis is related to the area of the sample that can be viewed at sufficient resolution. Here we present a simple and low-cost approach to mobile phone microscopy that uses a reversed mobile phone camera lens added to an intact mobile phone to enable high quality imaging over a significantly larger field of view than standard microscopy. We demonstrate use of the reversed lens mobile phone microscope to identify red and white blood cells in blood smears and soil-transmitted helminth eggs in stool samples. PMID:24854188

  12. Low-cost mobile phone microscopy with a reversed mobile phone camera lens.

    Directory of Open Access Journals (Sweden)

    Neil A Switz

    Full Text Available The increasing capabilities and ubiquity of mobile phones and their associated digital cameras offer the possibility of extending low-cost, portable diagnostic microscopy to underserved and low-resource areas. However, mobile phone microscopes created by adding magnifying optics to the phone's camera module have been unable to make use of the full image sensor due to the specialized design of the embedded camera lens, exacerbating the tradeoff between resolution and field of view inherent to optical systems. This tradeoff is acutely felt for diagnostic applications, where the speed and cost of image-based diagnosis is related to the area of the sample that can be viewed at sufficient resolution. Here we present a simple and low-cost approach to mobile phone microscopy that uses a reversed mobile phone camera lens added to an intact mobile phone to enable high quality imaging over a significantly larger field of view than standard microscopy. We demonstrate use of the reversed lens mobile phone microscope to identify red and white blood cells in blood smears and soil-transmitted helminth eggs in stool samples.

  13. Low-cost mobile phone microscopy with a reversed mobile phone camera lens.

    Science.gov (United States)

    Switz, Neil A; D'Ambrosio, Michael V; Fletcher, Daniel A

    2014-01-01

    The increasing capabilities and ubiquity of mobile phones and their associated digital cameras offer the possibility of extending low-cost, portable diagnostic microscopy to underserved and low-resource areas. However, mobile phone microscopes created by adding magnifying optics to the phone's camera module have been unable to make use of the full image sensor due to the specialized design of the embedded camera lens, exacerbating the tradeoff between resolution and field of view inherent to optical systems. This tradeoff is acutely felt for diagnostic applications, where the speed and cost of image-based diagnosis is related to the area of the sample that can be viewed at sufficient resolution. Here we present a simple and low-cost approach to mobile phone microscopy that uses a reversed mobile phone camera lens added to an intact mobile phone to enable high quality imaging over a significantly larger field of view than standard microscopy. We demonstrate use of the reversed lens mobile phone microscope to identify red and white blood cells in blood smears and soil-transmitted helminth eggs in stool samples.

  14. Robust Calibration of Cameras with Telephoto Lens Using Regularized Least Squares

    Directory of Open Access Journals (Sweden)

    Mingpei Liang

    2014-01-01

    Full Text Available Cameras with telephoto lens are usually used to recover details of an object that is either small or located far away from the cameras. However, the calibration of this kind of cameras is not as accurate as the one of cameras with short focal lengths that are commonly used in many vision applications. This paper has two contributions. First, we present a first-order error analysis that shows the relation between focal length and estimation uncertainties of camera parameters. To our knowledge, this error analysis with respect to focal length has not been studied in the area of camera calibration. Second, we propose a robust algorithm to calibrate the camera with a long focal length without using additional devices. By adding a regularization term, our algorithm makes the estimation of the image of the absolute conic well posed. As a consequence, the covariance of camera parameters can be reduced greatly. We further used simulations and real data to verify our proposed algorithm and obtained very stable results.

  15. Design study for a 16x zoom lens system for visible surveillance camera

    Science.gov (United States)

    Vella, Anthony; Li, Heng; Zhao, Yang; Trumper, Isaac; Gandara-Montano, Gustavo A.; Xu, Di; Nikolov, Daniel K.; Chen, Changchen; Brown, Nicolas S.; Guevara-Torres, Andres; Jung, Hae Won; Reimers, Jacob; Bentley, Julie

    2015-09-01

    *avella@ur.rochester.edu Design study for a 16x zoom lens system for visible surveillance camera Anthony Vella*, Heng Li, Yang Zhao, Isaac Trumper, Gustavo A. Gandara-Montano, Di Xu, Daniel K. Nikolov, Changchen Chen, Nicolas S. Brown, Andres Guevara-Torres, Hae Won Jung, Jacob Reimers, Julie Bentley The Institute of Optics, University of Rochester, Wilmot Building, 275 Hutchison Rd, Rochester, NY, USA 14627-0186 ABSTRACT High zoom ratio zoom lenses have extensive applications in broadcasting, cinema, and surveillance. Here, we present a design study on a 16x zoom lens with 4 groups (including two internal moving groups), designed for, but not limited to, a visible spectrum surveillance camera. Fifteen different solutions were discovered with nearly diffraction limited performance, using PNPX or PNNP design forms with the stop located in either the third or fourth group. Some interesting patterns and trends in the summarized results include the following: (a) in designs with such a large zoom ratio, the potential of locating the aperture stop in the front half of the system is limited, with ray height variations through zoom necessitating a very large lens diameter; (b) in many cases, the lens zoom motion has significant freedom to vary due to near zero total power in the middle two groups; and (c) we discuss the trade-offs between zoom configuration, stop location, packaging factors, and zoom group aberration sensitivity.

  16. Use and validation of mirrorless digital single light reflex camera for recording of vitreoretinal surgeries in high definition

    Directory of Open Access Journals (Sweden)

    Sumeet Khanduja

    2018-01-01

    Full Text Available Purpose: The purpose of this study is to describe the use of commercial digital single light reflex (DSLR for vitreoretinal surgery recording and compare it to standard 3-chip charged coupling device (CCD camera. Methods: Simultaneous recording was done using Sony A7s2 camera and Sony high-definition 3-chip camera attached to each side of the microscope. The videos recorded from both the camera systems were edited and sequences of similar time frames were selected. Three sequences that selected for evaluation were (a anterior segment surgery, (b surgery under direct viewing system, and (c surgery under indirect wide-angle viewing system. The videos of each sequence were evaluated and rated on a scale of 0-10 for color, contrast, and overall quality Results: Most results were rated either 8/10 or 9/10 for both the cameras. A noninferiority analysis by comparing mean scores of DSLR camera versus CCD camera was performed and P values were obtained. The mean scores of the two cameras were comparable for each other on all parameters assessed in the different videos except of color and contrast in posterior pole view and color on wide-angle view, which were rated significantly higher (better in DSLR camera. Conclusion: Commercial DSLRs are an affordable low-cost alternative for vitreoretinal surgery recording and may be used for documentation and teaching.

  17. Robust and adaptive band-to-band image transform of UAS miniature multi-lens multispectral camera

    Science.gov (United States)

    Jhan, Jyun-Ping; Rau, Jiann-Yeou; Haala, Norbert

    2018-03-01

    Utilizing miniature multispectral (MS) or hyperspectral (HS) cameras by mounting them on an Unmanned Aerial System (UAS) has the benefits of convenience and flexibility to collect remote sensing imagery for precision agriculture, vegetation monitoring, and environment investigation applications. Most miniature MS cameras adopt a multi-lens structure to record discrete MS bands of visible and invisible information. The differences in lens distortion, mounting positions, and viewing angles among lenses mean that the acquired original MS images have significant band misregistration errors. We have developed a Robust and Adaptive Band-to-Band Image Transform (RABBIT) method for dealing with the band co-registration of various types of miniature multi-lens multispectral cameras (Mini-MSCs) to obtain band co-registered MS imagery for remote sensing applications. The RABBIT utilizes modified projective transformation (MPT) to transfer the multiple image geometry of a multi-lens imaging system to one sensor geometry, and combines this with a robust and adaptive correction (RAC) procedure to correct several systematic errors and to obtain sub-pixel accuracy. This study applies three state-of-the-art Mini-MSCs to evaluate the RABBIT method's performance, specifically the Tetracam Miniature Multiple Camera Array (MiniMCA), Micasense RedEdge, and Parrot Sequoia. Six MS datasets acquired at different target distances and dates, and locations are also applied to prove its reliability and applicability. Results prove that RABBIT is feasible for different types of Mini-MSCs with accurate, robust, and rapid image processing efficiency.

  18. The Effect of a Pre-Lens Aperture on the Temperature Range and Image Uniformity of Microbolometer Infrared Cameras

    Energy Technology Data Exchange (ETDEWEB)

    Dinwiddie, Ralph Barton [ORNL; Parris, Larkin S. [Wichita State University; Lindal, John M. [Oak Ridge National Laboratory (ORNL); Kunc, Vlastimil [ORNL

    2016-01-01

    This paper explores the temperature range extension of long-wavelength infrared (LWIR) cameras by placing an aperture in front of the lens. An aperture smaller than the lens will reduce the radiance to the sensor, allowing the camera to image targets much hotter than typically allowable. These higher temperatures were accurately determined after developing a correction factor which was applied to the built-in temperature calibration. The relationship between aperture diameter and temperature range is linear. The effect of pre-lens apertures on the image uniformity is a form of anti-vignetting, meaning the corners appear brighter (hotter) than the rest of the image. An example of using this technique to measure temperatures of high melting point polymers during 3D printing provide valuable information of the time required for the weld-line temperature to fall below the glass transition temperature.

  19. Turning the Lens: Reflexivity in Research & Teaching with Critical Discourse Analysis

    Science.gov (United States)

    Warburton, Trevor

    2016-01-01

    This article explores the use of Critical Discourse Analysis in truth-telling in education research. I argue that without critical reflexivity Critical Discourse Analysis can become a means of reinforcing and reinscribing some of the same dominant discourses that we critique. Here I suggest the recognition that in the role of teacher and…

  20. Tracking the dynamics of skyglow with differential photometry using a digital camera with fisheye lens

    Science.gov (United States)

    Jechow, Andreas; Ribas, Salvador J.; Domingo, Ramon Canal; Hölker, Franz; Kolláth, Zoltán; Kyba, Christopher C. M.

    2018-04-01

    Artificial skyglow is dynamic due to changing atmospheric conditions and the switching on and off of artificial lights throughout the night. Street lights as well as the ornamental illumination of historical sites and buildings are sometimes switched off at a certain time to save energy. Ornamental lights in particular are often directed upwards, and can therefore have a major contribution towards brightening of the night sky. Here we use differential photometry to investigate the change in night sky brightness and illuminance during an automated regular switch-off of ornamental light in the town of Balaguer and an organized switch-off of all public lights in the village of Àger, both near Montsec Astronomical Park in Spain. The sites were observed during two nights with clear and cloudy conditions using a DSLR camera and a fisheye lens. A time series of images makes it possible to track changes in lighting conditions and sky brightness simultaneously. During the clear night, the ornamental lights in Balaguer contribute over 20% of the skyglow at zenith at the observational site. Furthermore, we are able to track very small changes in the ground illuminance on a cloudy night near Àger.

  1. Beyond photography: Evaluation of the consumer digital camera to identify strabismus and anisometropia by analyzing the Bruckner′s reflex

    Directory of Open Access Journals (Sweden)

    Sadat A. O. Bani

    2013-01-01

    Full Text Available Amblyopia screening is often either costly or laborious. We evaluated the Canon Powershot TX1 (CPTX1 digital camera as an efficient screener for amblyogenic risk factors (ARF. We included 138 subjects: 84-amblyopes and 54-normal. With the red-eye-reduction feature off, we obtained Bruckner reflex photographs of different sized crescents which suggested anisometropia, while asymmetrical brightness indicated strabismus; symmetry implied normalcy. Eight sets of randomly arranged 138 photographs were made. After training, 8 personnel, marked each as normal or abnormal. Of the 84 amblyopes, 42 were strabismus alone (SA, 36 had anisometropia alone (AA while six were mixed amblyopes (MA. Overall mean sensitivity for amblyopes was 0.86 (95% CI: 0.83-0.89 and specificity 0.85 (95% CI: 0.77-0.93. Sub-group analyses on SA, AA and MA returned sensitivities of 0.86, 0.89 and 0.69, while specificities were 0.85 for all three. Overall Cohen′s Kappa was 0.66 (95% CI: 0.62-0.71. The CPTX1 appears to be a feasible option to screen for ARF, although results need to be validated on appropriate age groups.

  2. Development and Optical Testing of the Camera, Hand Lens, and Microscope Probe with Scannable Laser Spectroscopy (CHAMP-SLS)

    Science.gov (United States)

    Mungas, Greg S.; Gursel, Yekta; Sepulveda, Cesar A.; Anderson, Mark; La Baw, Clayton; Johnson, Kenneth R.; Deans, Matthew; Beegle, Luther; Boynton, John

    2008-01-01

    Conducting high resolution field microscopy with coupled laser spectroscopy that can be used to selectively analyze the surface chemistry of individual pixels in a scene is an enabling capability for next generation robotic and manned spaceflight missions, civil, and military applications. In the laboratory, we use a range of imaging and surface preparation tools that provide us with in-focus images, context imaging for identifying features that we want to investigate at high magnification, and surface-optical coupling that allows us to apply optical spectroscopic analysis techniques for analyzing surface chemistry particularly at high magnifications. The camera, hand lens, and microscope probe with scannable laser spectroscopy (CHAMP-SLS) is an imaging/spectroscopy instrument capable of imaging continuously from infinity down to high resolution microscopy (resolution of approx. 1 micron/pixel in a final camera format), the closer CHAMP-SLS is placed to a feature, the higher the resultant magnification. At hand lens to microscopic magnifications, the imaged scene can be selectively interrogated with point spectroscopic techniques such as Raman spectroscopy, microscopic Laser Induced Breakdown Spectroscopy (micro-LIBS), laser ablation mass-spectrometry, Fluorescence spectroscopy, and/or Reflectance spectroscopy. This paper summarizes the optical design, development, and testing of the CHAMP-SLS optics.

  3. A Two-Stage Taguchi Design ExampleImage Quality Promotion in Miniature Camera/Cell-Phone Lens

    Directory of Open Access Journals (Sweden)

    Luke K. Wang

    2012-07-01

    Full Text Available A simple, practical manufacturing process, integrating manufacturing capability-oriented design (MCOD philosophy and Taguchi’s method, is presented to tackle the high resolution miniature camera/cell phone lens issues at the manufacturing phase. Meanwhile, we also use optical software to create an analytical simulation model to investigate the quality characteristics due to lens’ thickness, eccentricity, surface profile, and air lens’ gap; a single quality characteristics expressed in terms of modulation transfer function (MTF is defined. Optimal combination of process parameters in experimental scenario using Taguchi’s method is performed, and the results are judged and analyzed by the indices of signal-to-noise ratio (S/N and the analysis of variance (ANOVA. The key idea of the two-stage design is to utilize optical software to conduct the sensitivity analysis of MTF first; an analytical model, dependent on actual process parameters at manufacturing stage, is constructed next; and finally by substituting these outputs from the analytical model back to the optical software to verify the design criterion and do the modifications. By minimizing both the theoretical errors at design stage and the complexity in the manufacturing process, we are able to seeking for the most economical solution, simultaneously attain the optimal/suboptimal combination of process parameters or control factors in lens manufacturing issue.

  4. Determining camera parameters for round glassware measurements

    International Nuclear Information System (INIS)

    Baldner, F O; Costa, P B; Leta, F R; Gomes, J F S; Filho, D M E S

    2015-01-01

    Nowadays there are many types of accessible cameras, including digital single lens reflex ones. Although these cameras are not usually employed in machine vision applications, they can be an interesting choice. However, these cameras have many available parameters to be chosen by the user and it may be difficult to select the best of these in order to acquire images with the needed metrological quality. This paper proposes a methodology to select a set of parameters that will supply a machine vision system with the needed quality image, considering the measurement required of a laboratory glassware

  5. Feasibility study of a lens-coupled charge-coupled device gamma camera

    International Nuclear Information System (INIS)

    Lee, Hakjae; Jung, Youngjun; Kim, Jungmin; Bae, Seungbin; Lee, Kisung; Kang, Jungwon

    2011-01-01

    A charge-coupled device (CCD) is generally used in a digital camera as a light-collecting device such as a photomultiplier tube (PMT). Because of its low sensitivity and very high dark current, CCD have not been popularly used for gamma imaging systems. However, a recent CCD technological breakthrough has improved CCD sensitivity, and the use of a Peltier cooling system can significantly minimize the dark current. In this study, we investigated the feasibility of a prototype CCD gamma camera consisting of a CsI scintillator, optical lenses, and a CCD module. Despite electron-multiplying (EM) CCDs having higher performance, in this study, we built a cost-effective system consisted of low-cost components compared to EMCCDs. Our prototype detector consists of a CsI scintillator, two optical lenses, and a conventional Peltier-cooled CCD. The performance of this detector was evaluated by acquiring the sensitivity, resolution, and the modulation transfer function (MTF). The sensitivity of the prototype detector showed excellent linearity. With a 1 mm-diameter pinhole collimator, the full width at half-maximum (FWHM) of a 1.1 mm Tc-99m line source image was 2.85 mm. These results show that the developed prototype camera is feasible for small animal gamma imaging.

  6. Scheimpflug camera combined with placido-disk corneal topography and optical biometry for intraocular lens power calculation.

    Science.gov (United States)

    Kirgiz, Ahmet; Atalay, Kurşat; Kaldirim, Havva; Cabuk, Kubra Serefoglu; Akdemir, Mehmet Orcun; Taskapili, Muhittin

    2017-08-01

    The purpose of this study was to compare the keratometry (K) values obtained by the Scheimpflug camera combined with placido-disk corneal topography (Sirius) and optical biometry (Lenstar) for intraocular lens (IOL) power calculation before the cataract surgery, and to evaluate the accuracy of postoperative refraction. 50 eyes of 40 patients were scheduled to have phacoemulsification with the implantation of a posterior chamber intraocular lens. The IOL power was calculated using the SRK/T formula with Lenstar K and K readings from Sirius. Simulated K (SimK), K at 3-, 5-, and 7-mm zones from Sirius were compared with Lenstar K readings. The accuracy of these parameters was determined by calculating the mean absolute error (MAE). The mean Lenstar K value was 44.05 diopters (D) ±1.93 (SD) and SimK, K at 3-, 5-, and 7-mm zones were 43.85 ± 1.91, 43.88 ± 1.9, 43.84 ± 1.9, 43.66 ± 1.85 D, respectively. There was no statistically significant difference between the K readings (P = 0.901). When Lenstar was used for the corneal power measurements, MAE was 0.42 ± 0.33 D, but when simK of Sirius was used, it was 0.37 ± 0.32 D (the lowest MAE (0.36 ± 0.32 D) was achieved as a result of 5 mm K measurement), but it was not statistically significant (P = 0.892). Of all the K readings of Sirius and Lenstar, Sirius 5-mm zone K readings were the best in predicting a more precise IOL power. The corneal power measurements with the Scheimpflug camera combined with placido-disk corneal topography can be safely used for IOL power calculation.

  7. New algorithm for post-radial keratotomy intraocular lens power calculations based on rotating Scheimpflug camera data.

    Science.gov (United States)

    Potvin, Richard; Hill, Warren

    2013-03-01

    To provide an algorithm to calculate intraocular lens (IOL) power for post-radial keratometry (RK) eyes based on data extracted from the Pentacam Scheimpflug camera and to compare calculations with those from an existing standard. Private practice, Mesa, Arizona. Case series. Relevant IOL calculation and postoperative refractive data were obtained for eyes that had previous RK but no additional keratorefractive procedures or subsequent cataract surgery. Various Scheimpflug measurements from examinations before cataract surgery over a range of zone diameters were used to calculate IOL power using an Aramberri double-K-modified Holladay 1 formula. Results were compared with actual postsurgical data and IOL calculations based on the mean of the 1.0 mm to 4.0 mm rings from the Atlas topography system. Data were obtained for 83 eyes of 57 patients, including more than 120 different measures per eye from the Scheimpflug system. The mean pupil-centered sagittal front power over the central 4.0 mm zone provided the best results after adjustment for central corneal thickness (CCT). Results were similar to those obtained when the IOL power was calculated using the topography system; 42% of eyes were within ± 0.50 diopter (D) of the target, and 76% of eyes were within ± 1.00 D. In this large series of eyes, the calculation of IOL power after RK using sagittal front-surface power and CCT from the Scheimpflug system produced results equivalent to the multizone approach with the topography system. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. Through the Camera's Lens.

    Science.gov (United States)

    Maniquis, Robert M.

    1989-01-01

    Describes a program dealing with films depicting the French Revolution sponsored by the University of California Los Angeles. Emphasizes lectures and a colloquium discussing the ways in which films can transform common political ideas of the moment into popular memory of the past. Examines several films included in this national film…

  9. Estimating tiger abundance from camera trap data: Field surveys and analytical issues

    Science.gov (United States)

    Karanth, K. Ullas; Nichols, James D.; O'Connell, Allan F.; Nichols, James D.; Karanth, K. Ullas

    2011-01-01

    Automated photography of tigers Panthera tigris for purely illustrative purposes was pioneered by British forester Fred Champion (1927, 1933) in India in the early part of the Twentieth Century. However, it was McDougal (1977) in Nepal who first used camera traps, equipped with single-lens reflex cameras activated by pressure pads, to identify individual tigers and study their social and predatory behaviors. These attempts involved a small number of expensive, cumbersome camera traps, and were not, in any formal sense, directed at “sampling” tiger populations.

  10. X-ray imaging using digital cameras

    Science.gov (United States)

    Winch, Nicola M.; Edgar, Andrew

    2012-03-01

    The possibility of using the combination of a computed radiography (storage phosphor) cassette and a semiprofessional grade digital camera for medical or dental radiography is investigated. We compare the performance of (i) a Canon 5D Mk II single lens reflex camera with f1.4 lens and full-frame CMOS array sensor and (ii) a cooled CCD-based camera with a 1/3 frame sensor and the same lens system. Both systems are tested with 240 x 180 mm cassettes which are based on either powdered europium-doped barium fluoride bromide or needle structure europium-doped cesium bromide. The modulation transfer function for both systems has been determined and falls to a value of 0.2 at around 2 lp/mm, and is limited by light scattering of the emitted light from the storage phosphor rather than the optics or sensor pixelation. The modulation transfer function for the CsBr:Eu2+ plate is bimodal, with a high frequency wing which is attributed to the light-guiding behaviour of the needle structure. The detective quantum efficiency has been determined using a radioisotope source and is comparatively low at 0.017 for the CMOS camera and 0.006 for the CCD camera, attributed to the poor light harvesting by the lens. The primary advantages of the method are portability, robustness, digital imaging and low cost; the limitations are the low detective quantum efficiency and hence signal-to-noise ratio for medical doses, and restricted range of plate sizes. Representative images taken with medical doses are shown and illustrate the potential use for portable basic radiography.

  11. Infant reflexes

    Science.gov (United States)

    ... twitch their hips toward the touch in a dancing movement. GRASP REFLEX This reflex occurs if you ... Infant reflexes can occur in adults who have: Brain damage Stroke When to Contact a Medical Professional ...

  12. Performance evaluation of macro lens in digital close range photogrammetry

    Science.gov (United States)

    Yanagi, H.; Chikatsu, H.

    2009-08-01

    Recently, the documentation and visualization of various cultural heritages have been receiving attention, and a small Buddha such as less than 10 cm tall which was stored in the womb of Buddha is also included in cultural heritages. Zoom lenses are generally used to document these small objects and thus conserve the cultural heritage. However, there exist certain issues pertaining to the use of zoom lenses for such digital documentation. These issues include image sharpness and distortions that occur with changes in focal length setting, and in particular, the depth of field is issue from application standpoint such as documentation of the small cultural heritage. On the other hand, macro lenses can be used to capture sharp images of small objects from the view point of working distance, and its depth of field is related to the aperture of the camera. In order to evaluate the effectiveness of macro lenses in digital close range photogrammetry, macro lens and zoom lens were mounted on a digital single lens reflex camera (Canon EOS20D, 8.2 Mega pixels). This paper deals in a first part with comparative evaluations for both lenses with respect to their lens distortion, imaging mode, and calibration aspects. The results indicated that macro lenses were more suitable for digital close range photogrammetry. Calibration tests are performed to demonstrate the effectiveness and practicability of macro lens in close range photogrammetic applications.

  13. Fish-eye lens designs and their relative performance

    Science.gov (United States)

    Kumler, James J.; Bauer, Martin L.

    2000-10-01

    New panoramic and immersive digital imaging developments have generated increased interest in high performance fisheye camera lenses suitable for 35 mm single lens reflex (SLR) cameras. Special concerns for such applications are the uniformity of illumination and radial image mapping. Because two hemispherical images are digitally stitched together to form a complete 360-degree x 180-degree image, the performance of the lens at the 90 degree (preferably more than 90 degree) edge of the fisheye image is just as important as the center of the image. Lateral color, high order distortion (edge compression) and severe drop-off of illumination at the full field become obvious image defects and cause seams in the immersive image. Fisheye lens designs have widely varying relative illumination and distortion across the hemispherical field of view of the lens. After describing the contributing factors to relative illumination, we survey a collection of fisheye designs and compare their illumination performance, radial mapping and lateral color. A new method of measuring relative illumination and radial mapping in the laboratory is described and results on commercially available fish-eye lenses are presented.

  14. Photography in Dermatologic Surgery: Selection of an Appropriate Camera Type for a Particular Clinical Application.

    Science.gov (United States)

    Chen, Brian R; Poon, Emily; Alam, Murad

    2017-08-01

    Photographs are an essential tool for the documentation and sharing of findings in dermatologic surgery, and various camera types are available. To evaluate the currently available camera types in view of the special functional needs of procedural dermatologists. Mobile phone, point and shoot, digital single-lens reflex (DSLR), digital medium format, and 3-dimensional cameras were compared in terms of their usefulness for dermatologic surgeons. For each camera type, the image quality, as well as the other practical benefits and limitations, were evaluated with reference to a set of ideal camera characteristics. Based on these assessments, recommendations were made regarding the specific clinical circumstances in which each camera type would likely be most useful. Mobile photography may be adequate when ease of use, availability, and accessibility are prioritized. Point and shoot cameras and DSLR cameras provide sufficient resolution for a range of clinical circumstances, while providing the added benefit of portability. Digital medium format cameras offer the highest image quality, with accurate color rendition and greater color depth. Three-dimensional imaging may be optimal for the definition of skin contour. The selection of an optimal camera depends on the context in which it will be used.

  15. The use of ocular anatomical measurements using a rotating Scheimpflug camera to assist in the Esclera® scleral contact lens fitting process.

    Science.gov (United States)

    Weber, Sarah La Porta; Ambrósio, Renato; Lipener, César; Coral-Ghanem, Cleusa; Hofling-Lima, Ana Luisa

    2016-04-01

    To test for associations between Pentacam(®) derived topography variables and to evaluate the predictive power of those variables in relation to scleral contact lens (SCL) fit. Department of Ophthalmology and Visual Sciences, Federal University of São Paulo, São Paulo-SP, Brazil. Prospective observational non-randomised, non-comparative study. Forty-seven patients (63 eyes) were indicated for the use of Esclera(®) SCL. All patients underwent Scheimpflug imaging before the initial SCL evaluation. The following parameters were measured by Pentacam: corneal elevations, thickness, density, and anterior chamber depth (ACD). Correlations between the SCL parameters and the Pentacam measurements were analysed with Pearson's correlation coefficients. A simple linear regression model was created for each lens parameter using the most-correlated Pentacam variable. In the total group, the results show correlations between the SCL parameters and the corneal astigmatism, ACD and pentacam-measured corneal height (Hm), with p<0.001 each. In addition, an inverse correlation between the lens sagittal depth (LSD) and the anterior radii minimum was shown (p<0.001). In the keratoconus group, the results show correlations between the SCL parameters and ACD and Hm (p<0.001, each). An inverse correlation between the LSD and the total thickness corneal density average was also observed (p=0.003). There was a positive correlation between the LSD and ACD, even as LD and ACD in the keratoconus group. Thus, these results suggest that certain Pentacam measurements can be good predictors of the most appropriate Esclera lens to be fitted in keratoconus patients. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Reflexives and reflexive constructions in Afrikaans

    African Journals Online (AJOL)

    Kate H

    2. Reflexives. Afrikaans items belonging to the traditional lexical category of reflexives (or reflexive ... reflexive and non-reflexive pronouns are syntactically derived from the same lexical root pronoun √PRON. The ...... 32 The matrix verbs in (33) and (34) both concern a future activity of an entity: belowe (“promise”) in the (a).

  17. Radiometric calibration of wide-field camera system with an application in astronomy

    Science.gov (United States)

    Vítek, Stanislav; Nasyrova, Maria; Stehlíková, Veronika

    2017-09-01

    Camera response function (CRF) is widely used for the description of the relationship between scene radiance and image brightness. Most common application of CRF is High Dynamic Range (HDR) reconstruction of the radiance maps of imaged scenes from a set of frames with different exposures. The main goal of this work is to provide an overview of CRF estimation algorithms and compare their outputs with results obtained under laboratory conditions. These algorithms, typically designed for multimedia content, are unfortunately quite useless with astronomical image data, mostly due to their nature (blur, noise, and long exposures). Therefore, we propose an optimization of selected methods to use in an astronomical imaging application. Results are experimentally verified on the wide-field camera system using Digital Single Lens Reflex (DSLR) camera.

  18. Lens decenter and tilt measurement by interferogram

    Science.gov (United States)

    Hung, Min-Wei; Wu, Wen-Hong; Huang, Kuo-Cheng

    2009-11-01

    For the recent years, the vigorous development of the electro-optic industry, particularly the digital camera and the cellular phone camera, has placed a larger and larger demand for the optical devices. Among the optical lens, the aspherical optical lens plays the key component because the aspherical lens may provide better imaging quality then the spherical lens does. For the manufacturing reason, the aspherical lens is prone to a decenter or tilt issue with respect to the optical axes of its two surfaces. To measure decenter and tile error specifically would help to obviate the deficient lens, but most of the present measuring method can't provide this function. This paper proposed a new method to specifically measure the decenter and tile of lens by observing the interferogram of each surface. And the corresponding measuring instrument, which contains interferometer and motion stages, was introduced as well.

  19. A versatile photogrammetric camera automatic calibration suite for multi-spectral fusion and optical helmet tracking

    CSIR Research Space (South Africa)

    De Villiers, J

    2014-05-01

    Full Text Available This paper presents a system to determine the photogrammetric parameters of a camera. The lens distortion, focal length and camera six degree of freedom (DOF) position are calculated. The system caters for cameras of different sensitivity spectra...

  20. Objective lens

    Science.gov (United States)

    Olczak, Eugene G. (Inventor)

    2011-01-01

    An objective lens and a method for using same. The objective lens has a first end, a second end, and a plurality of optical elements. The optical elements are positioned between the first end and the second end and are at least substantially symmetric about a plane centered between the first end and the second end.

  1. Reflex sympathetic dystrophy.

    Science.gov (United States)

    Miller, Ruth L S

    2003-01-01

    Reflex sympathetic dystrophy, also known as complex regional pain syndrome type I, is a multisymptom syndrome usually affecting one or more extremities. It is inadequately understood and, therefore, often frustrating to treat. This article presents a case study of a 23-year career nurse who developed reflex sympathetic dystrophy of the left knee. It also reviews the rationale for reflex sympathetic dystrophy, treatment, and life-care planning for a patient with reflex sympathetic dystrophy.

  2. Performance analysis of digital cameras versus chromatic white light (CWL) sensors for the localization of latent fingerprints in crime scenes

    Science.gov (United States)

    Jankow, Mathias; Hildebrandt, Mario; Sturm, Jennifer; Kiltz, Stefan; Vielhauer, Claus

    2012-06-01

    In future applications of contactless acquisition techniques for latent fingerprints the automatic localization of potential fingerprint traces in crime scenes is required. Our goal is to study the application of a camera-based approach1 comparing with the performance of chromatic white light (CWL) techniques2 for the latent fingerprint localization in coarse and the resulting acquisition using detailed scans. Furthermore, we briefly evaluate the suitability of the camera-based acquisition for the detection of malicious fingerprint traces using an extended camera setup in comparison to Kiltz et al.3 Our experimental setup includes a Canon EOS 550D4 digital single-lens reflex (DSLR) camera and a FRT MicroProf2005 surface measurement device with CWL6002 sensor. We apply at least two fingerprints to each surface in our test set with 8 different either smooth, textured and structured surfaces to evaluate the detection performance of the two localization techniques using different pre-processing and feature extraction techniques. Printed fingerprint patterns as reproducible but potentially malicious traces3 are additionally acquired and analyzed on foil and compact discs. Our results indicate positive tendency towards a fast localization using the camera-based technique. All fingerprints that are located using the CWL sensor are found using the camera. However,the disadvantage of the camera-based technique is that the size of the region of interest for the detailed scan for each potential latent fingerprint is usually slightly larger compared to the CWL-based localization. Furthermore, this technique does not acquire 3D data and the resulting images are distorted due to the necessary angle between the camera and the surface. When applying the camera-based approach, it is required to optimize the feature extraction and classification. Furthermore, the required acquisition time for each potential fingerprint needs to be estimated to determine the time-savings of the

  3. Embodied Self-Reflexivity

    Science.gov (United States)

    Pagis, Michal

    2009-01-01

    Drawing on G. H. Mead and Merleau-Ponty, this paper aims to extend our understanding of self-reflexivity beyond the notion of a discursive, abstract, and symbolic process. It offers a framework for embodied self-reflexivity, which anchors the self in the reflexive capacity of bodily sensations. The data consist of two years of ethnographic…

  4. Epidemiology of reflex syncope

    NARCIS (Netherlands)

    Colman, N.; Nahm, K.; Ganzeboom, K. S.; Shen, W. K.; Reitsma, J.; Linzer, M.; Wieling, W.; Kaufmann, H.

    2004-01-01

    Cost-effective diagnostic approaches to reflex syncope require knowledge of its frequency and causes in different age groups. For this purpose we reviewed the available literature dealing with the epidemiology of reflex syncope. The incidence pattern of reflex syncope in the general population and

  5. Gamma camera

    International Nuclear Information System (INIS)

    Tschunt, E.; Platz, W.; Baer, Ul; Heinz, L.

    1978-01-01

    A gamma camera has a plurality of exchangeable collimators, one of which is replaceably mounted in the ray inlet opening of the camera, while the others are placed on separate supports. Supports are swingably mounted upon a column one above the other

  6. Gamma camera

    International Nuclear Information System (INIS)

    Schlosser, P.A.; Steidley, J.W.

    1980-01-01

    The design of a collimation system for a gamma camera for use in nuclear medicine is described. When used with a 2-dimensional position sensitive radiation detector, the novel system can produce superior images than conventional cameras. The optimal thickness and positions of the collimators are derived mathematically. (U.K.)

  7. Characterization of lens based photoacoustic imaging system

    Directory of Open Access Journals (Sweden)

    Kalloor Joseph Francis

    2017-12-01

    Full Text Available Some of the challenges in translating photoacoustic (PA imaging to clinical applications includes limited view of the target tissue, low signal to noise ratio and the high cost of developing real-time systems. Acoustic lens based PA imaging systems, also known as PA cameras are a potential alternative to conventional imaging systems in these scenarios. The 3D focusing action of lens enables real-time C-scan imaging with a 2D transducer array. In this paper, we model the underlying physics in a PA camera in the mathematical framework of an imaging system and derive a closed form expression for the point spread function (PSF. Experimental verification follows including the details on how to design and fabricate the lens inexpensively. The system PSF is evaluated over a 3D volume that can be imaged by this PA camera. Its utility is demonstrated by imaging phantom and an ex vivo human prostate tissue sample.

  8. Reflexivity: Licensing or enforcing

    OpenAIRE

    Schadler, D.

    2014-01-01

    During my research I looked at 117 languages and their anaphoric systems. The main goal of this study was to analyse reflexivization, its reasons and effects, by covering cross-linguistic data and by taking into account the variation we find on a macro- and micro-level. To be more precise, throughout this dissertation I investigated: whether we find indeed some special marking for reflexivity, i.e. licensing of reflexivity, across languages. whether there are complex reflexives that do not ha...

  9. Lens Model

    DEFF Research Database (Denmark)

    Nash, Ulrik William

    2014-01-01

    Firms consist of people who make decisions to achieve goals. How do these people develop the expectations which underpin the choices they make? The lens model provides one answer to this question. It was developed by cognitive psychologist Egon Brunswik (1952) to illustrate his theory...

  10. TESS Lens-Bezel Assembly Modal Testing

    Science.gov (United States)

    Dilworth, Brandon J.; Karlicek, Alexandra

    2017-01-01

    The Transiting Exoplanet Survey Satellite (TESS) program, led by the Kavli Institute for Astrophysics and Space Research at the Massachusetts Institute of Technology (MIT) will be the first-ever spaceborne all-sky transit survey. MIT Lincoln Laboratory is responsible for the cameras, including the lens assemblies, detector assemblies, lens hoods, and camera mounts. TESS is scheduled to be launched in August of 2017 with the primary goal to detect small planets with bright host starts in the solar neighborhood, so that detailed characterizations of the planets and their atmospheres can be performed. The TESS payload consists of four identical cameras and a data handling unit. Each camera consists of a lens assembly with seven optical elements and a detector assembly with four charge-coupled devices (CCDs) including their associated electronics. The optical prescription requires that several of the lenses are in close proximity to a neighboring element. A finite element model (FEM) was developed to estimate the relative deflections between each lens-bezel assembly under launch loads to predict that there are adequate clearances preventing the lenses from making contact. Modal tests using non-contact response measurements were conducted to experimentally estimate the modal parameters of the lens-bezel assembly, and used to validate the initial FEM assumptions. Key Words Non-contact measurements, modal analysis, model validation

  11. Cruciate ligament reflexes

    DEFF Research Database (Denmark)

    Krogsgaard, M.R.; Dyhre-Poulsen, Poul; Fischer-Rasmussen, T.

    2002-01-01

    The idea of muscular reflexes elicited from sensory nerves of the cruciate ligaments is more than 100 years old, but the existence of such reflexes has not been proven until the recent two decades. First in animal experiments, a muscular excitation could be elicited in the hamstrings when the ant...

  12. Too Busy for Reflexivity?

    DEFF Research Database (Denmark)

    Ratner, Helene

    colleagues” (Lynch 2000:46). Some 20 years later, these debates still linger in the shadows with some anthropologists refer to their work as “postreflexive” (eg. Maurer 2005, Riles 2000). This suggests a need to move beyond reflexivity without leaving it entirely behind. While reflexivity today still...

  13. Gamma camera

    International Nuclear Information System (INIS)

    Tschunt, E.; Platz, W.; Baer, U.; Heinz, L.

    1978-01-01

    A gamma camera has a plurality of exchangeable collimators, one of which is mounted in the ray inlet opening of the camera, while the others are placed on separate supports. The supports are swingably mounted upon a column one above the other through about 90 0 to a collimator exchange position. Each of the separate supports is swingable to a vertically aligned position, with limiting of the swinging movement and positioning of the support at the desired exchange position. The collimators are carried on the supports by means of a series of vertically disposed coil springs. Projections on the camera are movable from above into grooves of the collimator at the exchange position, whereupon the collimator is turned so that it is securely prevented from falling out of the camera head

  14. The PANOPTES project: discovering exoplanets with low-cost digital cameras

    Science.gov (United States)

    Guyon, Olivier; Walawender, Josh; Jovanovic, Nemanja; Butterfield, Mike; Gee, Wilfred T.; Mery, Rawad

    2014-07-01

    The Panoptic Astronomical Networked OPtical observatory for Transiting Exoplanets Survey (PANOPTES, www.projectpanoptes.org) project is aimed at identifying transiting exoplanets using a wide network of low-cost imaging units. Each unit consists of two commercial digital single lens reflex (DSLR) cameras equipped with 85mm F1.4 lenses, mounted on a small equatorial mount. At a few $1000s per unit, the system offers a uniquely advantageous survey eficiency for the cost, and can easily be assembled by amateur astronomers or students. Three generations of prototype units have so far been tested, and the baseline unit design, which optimizes robustness, simplicity and cost, is now ready to be duplicated. We describe the hardware and software for the PANOPTES project, focusing on key challenging aspects of the project. We show that obtaining high precision photometric measurements with commercial DSLR color cameras is possible, using a PSF-matching algorithm we developed for this project. On-sky tests show that percent-level photometric precision is achieved in 1 min with a single camera. We also discuss hardware choices aimed at optimizing system robustness while maintaining adequate cost. PANOPTES is both an outreach project and a scientifically compelling survey for transiting exoplanets. In its current phase, experienced PANOPTES members are deploying a limited number of units, acquiring the experience necessary to run the network. A much wider community will then be able to participate to the project, with schools and citizen scientists integrating their units in the network.

  15. Optical design of camera optics for mobile phones

    Science.gov (United States)

    Steinich, Thomas; Blahnik, Vladan

    2012-03-01

    At present, compact camera modules are included in many mobile electronic devices such as mobile phones, personal digital assistants or tablet computers. They have various uses, from snapshots of everyday situations to capturing barcodes for product information. This paper presents an overview of the key design challenges and some typical solutions. A lens design for a mobile phone camera is compared to a downscaled 35 mm format lens to demonstrate the main differences in optical design. Particular attention is given to scaling effects.

  16. Etnography and Reflexivity

    Directory of Open Access Journals (Sweden)

    Mario Cardano

    2014-01-01

    Full Text Available This essay deals with a relevant and controversial topic – objectivity in ethnographic research. More specifically, I would like to examine how reflexive procedures, more precisely “reflexive account”, can increase the robustness of results gained through an ethnographic research. The essay is organized in five parts. I will start by giving a preliminary definition of the two key concepts which are at the center of the analysis – objectivity and reflexivity. I will then give a brief description of the epistemological framework in which the proposed conceptions of objectivity and reflexivity are located. Thirdly, I move on to consider the epistemic status of ethnographic research, and will emphasize that ethnographies are not just “theory-laden”, as many writers have stated, but also “praxis” or “procedure laden”. In other words, I will stress that it is not only theories which are inevitably embedded in research, influencing how observations can be made; much the same can also be said of the concrete research practices which contribute to determine the experience of the ethnographer and its representation in a text. Fourthly, I will discuss why it is useful to employ reflexive practices, and then immediately afterwards will illustrate the ways in which reflexive descriptions can contribute to greater objectivity of ethnographic accounts. In conclusion, I will discuss a number of objections which have been raised against this use of reflexivity.

  17. The LSST camera system overview

    Science.gov (United States)

    Gilmore, Kirk; Kahn, Steven; Nordby, Martin; Burke, David; O'Connor, Paul; Oliver, John; Radeka, Veljko; Schalk, Terry; Schindler, Rafe

    2006-06-01

    The LSST camera is a wide-field optical (0.35-1um) imager designed to provide a 3.5 degree FOV with better than 0.2 arcsecond sampling. The detector format will be a circular mosaic providing approximately 3.2 Gigapixels per image. The camera includes a filter mechanism and, shuttering capability. It is positioned in the middle of the telescope where cross-sectional area is constrained by optical vignetting and heat dissipation must be controlled to limit thermal gradients in the optical beam. The fast, f/1.2 beam will require tight tolerances on the focal plane mechanical assembly. The focal plane array operates at a temperature of approximately -100°C to achieve desired detector performance. The focal plane array is contained within an evacuated cryostat, which incorporates detector front-end electronics and thermal control. The cryostat lens serves as an entrance window and vacuum seal for the cryostat. Similarly, the camera body lens serves as an entrance window and gas seal for the camera housing, which is filled with a suitable gas to provide the operating environment for the shutter and filter change mechanisms. The filter carousel can accommodate 5 filters, each 75 cm in diameter, for rapid exchange without external intervention.

  18. On Reflexive Data Models

    Energy Technology Data Exchange (ETDEWEB)

    Petrov, S.

    2000-08-20

    An information system is reflexive if it stores a description of its current structure in the body of stored information and is acting on the base of this information. A data model is reflexive, if its language is meta-closed and can be used to build such a system. The need for reflexive data models in new areas of information technology applications is argued. An attempt to express basic notions related to information systems is made in the case when the system supports and uses meta-closed representation of the data.

  19. Distribution and Parameter's Calculations of Television Cameras Inside a Nuclear Facility

    International Nuclear Information System (INIS)

    El-kafas, A.A.

    2009-01-01

    In this work, a distribution of television cameras and parameter's calculation inside and outside a nuclear facility is presented. Each of exterior and interior camera systems will be described and explained. The work shows the overall closed circuit television system. Fixed and moving cameras with various lens format and different angles of view are used. The calculations of width of images sensitive area and Lens focal length for the cameras will be introduced. The work shows the camera locations and distributions inside and outside the nuclear facility. The technical specifications and parameters for cameras selection are tabulated

  20. A semi-automatic image-based close range 3D modeling pipeline using a multi-camera configuration.

    Science.gov (United States)

    Rau, Jiann-Yeou; Yeh, Po-Chia

    2012-01-01

    The generation of photo-realistic 3D models is an important task for digital recording of cultural heritage objects. This study proposes an image-based 3D modeling pipeline which takes advantage of a multi-camera configuration and multi-image matching technique that does not require any markers on or around the object. Multiple digital single lens reflex (DSLR) cameras are adopted and fixed with invariant relative orientations. Instead of photo-triangulation after image acquisition, calibration is performed to estimate the exterior orientation parameters of the multi-camera configuration which can be processed fully automatically using coded targets. The calibrated orientation parameters of all cameras are applied to images taken using the same camera configuration. This means that when performing multi-image matching for surface point cloud generation, the orientation parameters will remain the same as the calibrated results, even when the target has changed. Base on this invariant character, the whole 3D modeling pipeline can be performed completely automatically, once the whole system has been calibrated and the software was seamlessly integrated. Several experiments were conducted to prove the feasibility of the proposed system. Images observed include that of a human being, eight Buddhist statues, and a stone sculpture. The results for the stone sculpture, obtained with several multi-camera configurations were compared with a reference model acquired by an ATOS-I 2M active scanner. The best result has an absolute accuracy of 0.26 mm and a relative accuracy of 1:17,333. It demonstrates the feasibility of the proposed low-cost image-based 3D modeling pipeline and its applicability to a large quantity of antiques stored in a museum.

  1. Gamma camera

    International Nuclear Information System (INIS)

    Reiss, K.H.; Kotschak, O.; Conrad, B.

    1976-01-01

    A gamma camera with a simplified setup as compared with the state of engineering is described permitting, apart from good localization, also energy discrimination. Behind the usual vacuum image amplifier a multiwire proportional chamber filled with trifluorine bromium methane is connected in series. Localizing of the signals is achieved by a delay line, energy determination by means of a pulse height discriminator. With the aid of drawings and circuit diagrams, the setup and mode of operation are explained. (ORU) [de

  2. Wavefront analysis for plenoptic camera imaging

    International Nuclear Information System (INIS)

    Luan Yin-Sen; Xu Bing; Yang Ping; Tang Guo-Mao

    2017-01-01

    The plenoptic camera is a single lens stereo camera which can retrieve the direction of light rays while detecting their intensity distribution. In this paper, to reveal more truths of plenoptic camera imaging, we present the wavefront analysis for the plenoptic camera imaging from the angle of physical optics but not from the ray tracing model of geometric optics. Specifically, the wavefront imaging model of a plenoptic camera is analyzed and simulated by scalar diffraction theory and the depth estimation is redescribed based on physical optics. We simulate a set of raw plenoptic images of an object scene, thereby validating the analysis and derivations and the difference between the imaging analysis methods based on geometric optics and physical optics are also shown in simulations. (paper)

  3. Contact lens in keratoconus

    Directory of Open Access Journals (Sweden)

    Varsha M Rathi

    2013-01-01

    Full Text Available Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP lenses, soft and soft toric lenses, piggy back contact lenses (PBCL, hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the English language with the keywords keratoconus and various contact lenses such as Rose k lens, RGP lens, hybrid lens, scleral lens and PBCL.

  4. Contact lens in keratoconus

    Science.gov (United States)

    Rathi, Varsha M; Mandathara, Preeji S; Dumpati, Srikanth

    2013-01-01

    Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP) lenses, soft and soft toric lenses, piggy back contact lenses (PBCL), hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the English language with the keywords keratoconus and various contact lenses such as Rose k lens, RGP lens, hybrid lens, scleral lens and PBCL. PMID:23925325

  5. Too Busy for Reflexivity?

    DEFF Research Database (Denmark)

    Ratner, Helene

    of a “corrosive relativism in which everything is but a more or less clever expression of opinion” (Geertz 1988:2, 3) and it has suffered the little flattering accusations of piling "layer upon layer of self-consciousness to no avail" (Latour 1988:170) with little “interest [for] … theoretically ambitious...... of reflexivity. Facing these challenges, the managers employ a pragmatic moral, which allows them to bracket or defer their epistemological ideal of reflexivity while keeping it alive as exactly that: a promise of a future settlement. The paper concludes by comparing academics’ and school managers’ versions...

  6. Reflexivity and social justice

    DEFF Research Database (Denmark)

    Maksimovic, Tijana; Jakobsen, Helle Nordentoft

    2017-01-01

    Career practitioners’ reflexive understanding of their professional role as change agents in career guidance and counselling practices has a major impact on how social justice can be achieved. This entitles an awareness of the way in which guidance and counselling practices are embedded in the co......Career practitioners’ reflexive understanding of their professional role as change agents in career guidance and counselling practices has a major impact on how social justice can be achieved. This entitles an awareness of the way in which guidance and counselling practices are embedded...

  7. Corneomandibular reflex: Anatomical basis

    Directory of Open Access Journals (Sweden)

    Michele Pistacchi

    2015-01-01

    Full Text Available Corneomandibular reflex is a pathological phenomenon evident in cases of severe brainstem damage. It is considered to be a pathological exteroceptive reflex, associated with precentro bulbar tract lesions. The sign is useful in distinguishing central neurological injuries to metabolic disorders in acutely comatose patients, localizing lesions to the upper brainstem area, determining the depth of coma and its evolution, providing evidence of uncal or transtentorial herniation in acute cerebral hemisphere lesions, and it is a marker of supraspinal level impairment in amyotrophic lateral sclerosis and multiple sclerosis. This sign was evident in a patient with severe brain damage. We discuss the literature findings and its relevance in prognosis establishment.

  8. Reflexivity in qualitative research

    DEFF Research Database (Denmark)

    Evans, Adam Brian; Nistrup, Anne; Henderson, Hannah

    2018-01-01

    practice, that is, to reflect on our own values, beliefs, and biographies. It can be difficult to know exactly how a researcher should engage in these practices, however. Here, we discuss our reflexive practice in two case studies, both which utilized the same figurational theoretical framework....... In Study 2, changes in study goals meant that retrospective reflexive practice was necessary, while the principal researcher had an established relationship with participants in the study, which made reflection on her perspective vital. We conclude by highlighting the importance of methodological...

  9. Quantitative Evaluation of Surface Color of Tomato Fruits Cultivated in Remote Farm Using Digital Camera Images

    Science.gov (United States)

    Hashimoto, Atsushi; Suehara, Ken-Ichiro; Kameoka, Takaharu

    To measure the quantitative surface color information of agricultural products with the ambient information during cultivation, a color calibration method for digital camera images and a remote monitoring system of color imaging using the Web were developed. Single-lens reflex and web digital cameras were used for the image acquisitions. The tomato images through the post-ripening process were taken by the digital camera in both the standard image acquisition system and in the field conditions from the morning to evening. Several kinds of images were acquired with the standard RGB color chart set up just behind the tomato fruit on a black matte, and a color calibration was carried out. The influence of the sunlight could be experimentally eliminated, and the calibrated color information consistently agreed with the standard ones acquired in the system through the post-ripening process. Furthermore, the surface color change of the tomato on the tree in a greenhouse was remotely monitored during maturation using the digital cameras equipped with the Field Server. The acquired digital color images were sent from the Farm Station to the BIFE Laboratory of Mie University via VPN. The time behavior of the tomato surface color change during the maturing process could be measured using the color parameter calculated based on the obtained and calibrated color images along with the ambient atmospheric record. This study is a very important step in developing the surface color analysis for both the simple and rapid evaluation of the crop vigor in the field and to construct an ambient and networked remote monitoring system for food security, precision agriculture, and agricultural research.

  10. Gamma camera

    International Nuclear Information System (INIS)

    Berninger, W.H.

    1975-01-01

    The light pulse output of a scintillator, on which incident collimated gamma rays impinge, is detected by an array of photoelectric tubes each having a convexly curved photocathode disposed in close proximity to the scintillator. Electronic circuitry connected to outputs of the phototubes develops the scintillation event position coordinate electrical signals with good linearity and with substantial independence of the spacing between the scintillator and photocathodes so that the phototubes can be positioned as close to the scintillator as is possible to obtain less distortion in the field of view and improved spatial resolution as compared to conventional planar photocathode gamma cameras

  11. Calculation of lens alignment errors using the ray transfer matrices for the lens assembly system with an autocollimator and a rotation stage

    Science.gov (United States)

    Chu, Jiyoung; Cho, Sungwhi; Joo, Won Don; Jang, Sangdon

    2017-08-01

    One of the most popular methods for high precision lens assembly of an optical system is using an autocollimator and a rotation stage. Some companies provide software for calculating the state of the lens along with their lens assembly systems, but the calculation algorithms used by the software are unknown. In this paper, we suggest a calculation method for lens alignment errors using ray transfer matrices. Alignment errors resulting from tilting and decentering of a lens element can be calculated from the tilts of the front and back surfaces of the lens. The tilt of each surface can be obtained from the position of the reticle image on the CCD camera of the autocollimator. Rays from a reticle of the autocollimator are reflected from the target surface of the lens, which rotates with the rotation stage, and are imaged on the CCD camera. To obtain a clear image, the distance between the autocollimator and the first lens surface should be adjusted according to the focusing lens of the autocollimator and the lens surfaces from the first to the target surface. Ray propagations for the autocollimator and the tilted lens surfaces can be expressed effectively by using ray transfer matrices and lens alignment errors can be derived from them. This method was compared with Zemax simulation for various lenses with spherical or flat surfaces and the error was less than a few percent.

  12. On the evolution of wafer level cameras

    Science.gov (United States)

    Welch, H.

    2011-02-01

    The introduction of small cost effective cameras based on CMOS image sensor technology has played an important role in the revolution in mobile devices of the last 10 years. Wafer-based optics manufacturing leverages the same fabrication equipment used to produce CMOS sensors. The natural integration of these two technologies allows the mass production of very low cost surface mount cameras that can fit into ever thinner mobile devices. Nano Imprint Lithography (NIL) equipment has been adapted to make precision aspheres that can be stacked using wafer bonding techniques to produce multi-element lens assemblies. This, coupled with advances in mastering technology, allows arrays of lenses with prescriptions not previously possible. A primary motivation for these methods is that it allows the consolidation of the supply chain. Image sensor manufacturers envision creating optics by simply adding layers to their existing sensor fabrication lines. Results thus far have been promising. The current alternative techniques for creating VGA cameras are discussed as well as the prime cost drivers for lens to sensor integration. Higher resolution cameras face particularly difficult challenges, but can greatly simplify the critical tilt and focus steps needed to assemble cameras that produce quality images. Finally, we discuss the future of wafer-level cameras and explore several of the novel concepts made possible by the manufacturing advantages of photolithography.

  13. Reflexivity of Routines

    DEFF Research Database (Denmark)

    Yamauchi, Yutaka; Hiramoto, Takeshi

    2016-01-01

    This study reconsiders the meaning and implications of reflexivity for the theory of routines. Due to their mundane nature, routines tend to be considered unambiguous phenomena that everyone can readily understand. The performative theory of routines has challenged this view by suggesting there i...

  14. Accuracy of fish-eye lens models.

    Science.gov (United States)

    Hughes, Ciarán; Denny, Patrick; Jones, Edward; Glavin, Martin

    2010-06-10

    The majority of computer vision applications assumes that the camera adheres to the pinhole camera model. However, most optical systems will introduce undesirable effects. By far, the most evident of these effects is radial lensing, which is particularly noticeable in fish-eye camera systems, where the effect is relatively extreme. Several authors have developed models of fish-eye lenses that can be used to describe the fish-eye displacement. Our aim is to evaluate the accuracy of several of these models. Thus, we present a method by which the lens curve of a fish-eye camera can be extracted using well-founded assumptions and perspective methods. Several of the models from the literature are examined against this empirically derived curve.

  15. Reflex epilepsy: a review

    Directory of Open Access Journals (Sweden)

    Karim Nikkhah

    2017-01-01

    Full Text Available Interesting phenomena of reflex epileptic syndromes are characterized by epileptic seizures each one induced by specific stimulus with a variety of types. Simple triggers, which lead to seizures within seconds, are of sensory type (most commonly visual, most rarely tactile or proprioceptive stimuli. Complex triggers, which are mostly of cognitive type such as praxis, reading, talking, and music, usually induce the epileptic event within minutes. It should differ from what most epileptic patients report as provocative precipitants for seizures (such as emotional stress, fatigue, fever, sleep deprivation, alcohol, and menstrual cycle. The identification of a specific trigger is not only important for patients or their parents to avoid seizures, but also it might help neurologists to choose the most effective antiepileptic drug for each case. In addition, research in this area may possibly reveal some underlying pathophysiology of epileptic phenomena in the brain.In this review, we briefly introduce reported reflex epileptic seizures, their clinical features and management.

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... lens because they can be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, ... Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume Contacts May Contain Chemicals Harmful to Eyes ...

  17. Corporeal reflexivity and autism.

    Science.gov (United States)

    Ochs, Elinor

    2015-06-01

    Ethnographic video recordings of high functioning children with autism or Aspergers Syndrome in everyday social encounters evidence their first person perspectives. High quality visual and audio data allow detailed analysis of children's bodies and talk as loci of reflexivity. Corporeal reflexivity involves displays of awareness of one's body as an experiencing subject and a physical object accessible to the gaze of others. Gaze, demeanor, actions, and sotto voce commentaries on unfolding situations indicate a range of moment-by-moment reflexive responses to social situations. Autism is associated with neurologically based motor problems (e.g. delayed action-goal coordination, clumsiness) and highly repetitive movements to self-soothe. These behaviors can provoke derision among classmates at school. Focusing on a 9-year-old girl's encounters with peers on the playground, this study documents precisely how autistic children can become enmeshed as unwitting objects of stigma and how they reflect upon their social rejection as it transpires. Children with autism spectrum disorders in laboratory settings manifest diminished understandings of social emotions such as embarrassment, as part of a more general impairment in social perspective-taking. Video ethnography, however, takes us further, into discovering autistic children's subjective sense of vulnerability to the gaze of classmates.

  18. Simplification of camera models without loss of precision

    Science.gov (United States)

    Shang, Yang; Li, You; He, Yan; Wang, Weihua; Yu, Qifeng

    2007-12-01

    Camera parameters' redundancy and actions on imaging process are analyzed based on central perspective projection model with nonlinear lens distortion. By assigning some parameters' values or their relations in advance, seven kinds of simplified camera models are presented. The simplified models' availability is validated by simulated data and engineering applications. By using the simplified camera models, methods and arithmetics of videogrammetry can be simplified without precision losses. The calculation becomes faster and stabler. The solving condition requirements are reduced. These characteristics make the precision-reserved simplified camera models availible for engineering applications.

  19. Airborne hyperspectral observations of surface and cloud directional reflectivity using a commercial digital camera

    Directory of Open Access Journals (Sweden)

    A. Ehrlich

    2012-04-01

    Full Text Available Spectral radiance measurements by a digital single-lens reflex camera were used to derive the directional reflectivity of clouds and different surfaces in the Arctic. The camera has been calibrated radiometrically and spectrally to provide accurate radiance measurements with high angular resolution. A comparison with spectral radiance measurements with the Spectral Modular Airborne Radiation measurement sysTem (SMART-Albedometer showed an agreement within the uncertainties of both instruments (6% for both. The directional reflectivity in terms of the hemispherical directional reflectance factor (HDRF was obtained for sea ice, ice-free ocean and clouds. The sea ice, with an albedo of ρ = 0.96 (at 530 nm wavelength, showed an almost isotropic HDRF, while sun glint was observed for the ocean HDRF (ρ = 0.12. For the cloud observations with ρ = 0.62, the cloudbow – a backscatter feature typically for scattering by liquid water droplets – was covered by the camera. For measurements above heterogeneous stratocumulus clouds, the required number of images to obtain a mean HDRF that clearly exhibits the cloudbow has been estimated at about 50 images (10 min flight time. A representation of the HDRF as a function of the scattering angle only reduces the image number to about 10 (2 min flight time.

    The measured cloud and ocean HDRF have been compared to radiative transfer simulations. The ocean HDRF simulated with the observed surface wind speed of 9 m s−1 agreed best with the measurements. For the cloud HDRF, the best agreement was obtained by a broad and weak cloudbow simulated with a cloud droplet effective radius of Reff = 4 μm. This value agrees with the particle sizes derived from in situ measurements and retrieved from the spectral radiance of the SMART-Albedometer.

  20. Photometric Calibration and Image Stitching for a Large Field of View Multi-Camera System

    OpenAIRE

    Yu Lu; Keyi Wang; Gongshu Fan

    2016-01-01

    A new compact large field of view (FOV) multi-camera system is introduced. The camera is based on seven tiny complementary metal-oxide-semiconductor sensor modules covering over 160? ? 160? FOV. Although image stitching has been studied extensively, sensor and lens differences have not been considered in previous multi-camera devices. In this study, we have calibrated the photometric characteristics of the multi-camera device. Lenses were not mounted on the sensor in the process of radiometri...

  1. Soleus stretch reflex during cycling

    DEFF Research Database (Denmark)

    Grey, Michael James; Pierce, C. W.; Milner, T. E.

    2001-01-01

    the crank cycle, producing ankle dorsiflexion perturbations of similar trajectory. The stretch reflex was greatest during the power phase of the crank cycle and was decreased to the level of background EMG during recovery. Matched perturbations were induced under static conditions at the same crank angle...... active cycling as has been shown with the H-reflex. This lack of depression may reflect a decreased susceptibility of the stretch reflex to inhibition, possibly originating from presynaptic mechanisms....

  2. The Light Field Attachment: Turning a DSLR into a Light Field Camera Using a Low Budget Camera Ring.

    Science.gov (United States)

    Wang, Yuwang; Liu, Yebin; Heidrich, Wolfgang; Dai, Qionghai

    2017-10-01

    We propose a concept for a lens attachment that turns a standard DSLR camera and lens into a light field camera. The attachment consists of eight low-resolution, low-quality side cameras arranged around the central high-quality SLR lens. Unlike most existing light field camera architectures, this design provides a high-quality 2D image mode, while simultaneously enabling a new high-quality light field mode with a large camera baseline but little added weight, cost, or bulk compared with the base DSLR camera. From an algorithmic point of view, the high-quality light field mode is made possible by a new light field super-resolution method that first improves the spatial resolution and image quality of the side cameras and then interpolates additional views as needed. At the heart of this process is a super-resolution method that we call iterative Patch- And Depth-based Synthesis (iPADS), which combines patch-based and depth-based synthesis in a novel fashion. Experimental results obtained for both real captured data and synthetic data confirm that our method achieves substantial improvements in super-resolution for side-view images as well as the high-quality and view-coherent rendering of dense and high-resolution light fields.

  3. The Light Field Attachment: Turning a DSLR into a Light Field Camera Using a Low Budget Camera Ring

    KAUST Repository

    Wang, Yuwang

    2016-11-16

    We propose a concept for a lens attachment that turns a standard DSLR camera and lens into a light field camera. The attachment consists of 8 low-resolution, low-quality side cameras arranged around the central high-quality SLR lens. Unlike most existing light field camera architectures, this design provides a high-quality 2D image mode, while simultaneously enabling a new high-quality light field mode with a large camera baseline but little added weight, cost, or bulk compared with the base DSLR camera. From an algorithmic point of view, the high-quality light field mode is made possible by a new light field super-resolution method that first improves the spatial resolution and image quality of the side cameras and then interpolates additional views as needed. At the heart of this process is a super-resolution method that we call iterative Patch- And Depth-based Synthesis (iPADS), which combines patch-based and depth-based synthesis in a novel fashion. Experimental results obtained for both real captured data and synthetic data confirm that our method achieves substantial improvements in super-resolution for side-view images as well as the high-quality and view-coherent rendering of dense and high-resolution light fields.

  4. The MVACS Robotic Arm Camera

    Science.gov (United States)

    Keller, H. U.; Hartwig, H.; Kramm, R.; Koschny, D.; Markiewicz, W. J.; Thomas, N.; Fernades, M.; Smith, P. H.; Reynolds, R.; Lemmon, M. T.; Weinberg, J.; Marcialis, R.; Tanner, R.; Boss, B. J.; Oquest, C.; Paige, D. A.

    2001-08-01

    The Robotic Arm Camera (RAC) is one of the key instruments newly developed for the Mars Volatiles and Climate Surveyor payload of the Mars Polar Lander. This lightweight instrument employs a front lens with variable focus range and takes images at distances from 11 mm (image scale 1:1) to infinity. Color images with a resolution of better than 50 μm can be obtained to characterize the Martian soil. Spectral information of nearby objects is retrieved through illumination with blue, green, and red lamp sets. The design and performance of the camera are described in relation to the science objectives and operation. The RAC uses the same CCD detector array as the Surface Stereo Imager and shares the readout electronics with this camera. The RAC is mounted at the wrist of the Robotic Arm and can characterize the contents of the scoop, the samples of soil fed to the Thermal Evolved Gas Analyzer, the Martian surface in the vicinity of the lander, and the interior of trenches dug out by the Robotic Arm. It can also be used to take panoramic images and to retrieve stereo information with an effective baseline surpassing that of the Surface Stereo Imager by about a factor of 3.

  5. The moving camera in Flimmer

    DEFF Research Database (Denmark)

    Juel, Henrik

    2018-01-01

    No human actors are seen, but Flimmer still seethes with motion, both motion within the frame and motion of the frame. The subtle camera movements, perhaps at first unnoticed, play an important role in creating the poetic mood of the film, curious, playful and reflexive....

  6. Reflexive Dressing: Rethinking Retro

    Directory of Open Access Journals (Sweden)

    Stella North

    2016-03-01

    Full Text Available This article undertakes a philosophical exploration of the act we know, or think we know, as ‘dressing’. Inhabiting, in thought, the moment in which we dress, I examine some of its constituent mechanisms, attending to the impulses by which dressing is generated out of subjective experience.  When those impulses are temporally marked, as they are in the case of retro dress, this generation is a two-pronged process, in which the holding of the body in time, and the holding of time in the body, recalibrate one another. The process of ‘dressing,’ in this understanding, has a reflexivity which is double; it entails the turning of the body, with dress as medium, towards itself, and the turning of present experience towards some felt notion of the past. Reflexively dressing, we are always becoming ourselves, and becoming other than ourselves, at once; a movement of circuitous internalisation and externalisation by which the ambiguation inherent in material experience is realised.

  7. On orbit-reflexive operators

    Czech Academy of Sciences Publication Activity Database

    Müller, Vladimír; Vršovský, Jan

    2009-01-01

    Roč. 79, č. 2 (2009), s. 497-510 ISSN 0024-6107 Institutional research plan: CEZ:AV0Z10190503 Keywords : reflexive operators * orbit-reflexivity Subject RIV: BA - General Mathematics Impact factor: 0.798, year: 2009

  8. AMPUTATION AND REFLEX SYMPATHETIC DYSTROPHY

    NARCIS (Netherlands)

    GEERTZEN, JHB; EISMA, WH

    Reflex sympathetic dystrophy is a chronic pain syndrome characterized by chronic burning pain, restricted range of motion, oedema and vasolability. Patients are difficult to treat and the prognosis is very often poor. This report emphasizes that an amputation in case of a reflex sympathetic

  9. Nonpharmacological treatment of reflex syncope

    NARCIS (Netherlands)

    Wieling, Wouter; Colman, Nancy; Krediet, C. T. Paul; Freeman, Roy

    2004-01-01

    Reflex syncope is a common medical problem. Vasovagal reflex syncope is the most frequent form. Although the prognosis of the disorder is excellent, it may impose substantial changes in life style and cause profound psychological distress. Thus, management of this disorder is an important issue.

  10. [Reflex seizures, cinema and television].

    Science.gov (United States)

    Olivares-Romero, Jesús

    2015-12-16

    In movies and television series are few references to seizures or reflex epilepsy even though in real life are an important subgroup of total epileptic syndromes. It has performed a search on the topic, identified 25 films in which they appear reflex seizures. Most seizures observed are tonic-clonic and visual stimuli are the most numerous, corresponding all with flashing lights. The emotions are the main stimuli in higher level processes. In most cases it is not possible to know if a character suffers a reflex epilepsy or suffer reflex seizures in the context of another epileptic syndrome. The main conclusion is that, in the movies, the reflex seizures are merely a visual reinforcing and anecdotal element without significant influence on the plot.

  11. REFRACTIVE NEUTRON LENS

    OpenAIRE

    Petrov, P. V.; Kolchevsky, N. N.

    2013-01-01

    Compound concave refractive lenses are used for focusing neutron beam. Investigations of spectral and focusing properties of a refractive neutron lens are presented. Resolution of the imaging system on the base of refractive neutron lenses depends on material properties and parameters of neutron source. Model of refractive neutron lens are proposed. Results of calculation diffraction resolution and focal depth of refractive neutron lens are discussed.

  12. Contact lens in keratoconus

    OpenAIRE

    Rathi, Varsha M; Mandathara, Preeji S; Dumpati, Srikanth

    2013-01-01

    Contact lenses are required for the visual improvement in patients with keratoconus. Various contact lens options, such as rigid gas permeable (RGP) lenses, soft and soft toric lenses, piggy back contact lenses (PBCL), hybrid lenses and scleral lenses are availble. This article discusses about selection of a lens depending on the type of keratoconus and the fitting philosophies of various contact lenses including the starting trial lens. A Medline search was carried out for articles in the En...

  13. Reflex sympathetic dystrophy in hemiplegia.

    Science.gov (United States)

    Gokkaya, Nilufer Kutay Ordu; Aras, Meltem; Yesiltepe, Elcin; Koseoglu, Fusun

    2006-12-01

    There is a high incidence of reflex sympathetic dystrophy of the upper limbs in patients with hemiplegia, and its painful and functional consequences present a problem to specialists in physical medicine and rehabilitation. This study was designed to assess the role of several factors in the occurrence of reflex sympathetic dystrophy in patients with hemiplegia. Ninety-five consecutive stroke patients (63 male and 32 female, mean age 59+/-12 years) admitted to our hospital were evaluated. Of the study group, 29 patients (30.5%) were found to develop reflex sympathetic dystrophy. There were no significant differences between the hemiplegic patient groups with or without reflex sympathetic dystrophy regarding age, gender, etiology, side of involvement, disease duration and the presence of comorbidities. The recovery stages of hemiplegia, as shown by Brunnstrom functional classification, were significantly different between the two groups; patients in lower recovery stages tended to develop reflex sympathetic dystrophy more frequently (Preflex sympathetic dystrophy. Glenohumeral subluxation was present in 37 patients (38.9%) in our study group and the presence of this complication was related to the occurrence of reflex sympathetic dystrophy. The presence of glenohumeral subluxation was significantly higher in patients with reflex sympathetic dystrophy (21/29, 72.4%) when compared to the patients without reflex sympathetic dystrophy (16/66, 24.2%) (Preflex sympathetic dystrophy. These results suggest that lower recovery stages, reduced tonus and glenohumeral subluxation significantly contribute to the occurrence of reflex sympathetic dystrophy in the hemiplegic patient. We believe that preventive and treatment measures should consider these factors as they seem to have in common a higher risk of traumatizing the paralyzed upper limb and causing reflex sympathetic dystrophy.

  14. Reflexivity and social justice

    DEFF Research Database (Denmark)

    Maksimovic, Tijana; Jakobsen, Helle Nordentoft

    2017-01-01

    in the complexity of causes of social injustice in their own environment – i.e. how these are perpetuated in the design and implementation of national and organisational policies and how they influence counselling relationships. A generic challenge in career guidance is, for instance, to help individuals follow......Career practitioners’ reflexive understanding of their professional role as change agents in career guidance and counselling practices has a major impact on how social justice can be achieved. This entitles an awareness of the way in which guidance and counselling practices are embedded....... In this chapter, we argue that career practitioners may perpetuate social inequalities by not reflecting on how they themselves potentially take part in the reproduction of dominant discourses when they navigate and handle these tensions. In particular, the dominance of neo-liberal discourse in institutional...

  15. Three-camera setup to record simultaneously standardized high-definition video for smile analysis.

    Science.gov (United States)

    Husain, Akhter; Makhija, Parmanand G; Ummer, Aseena Alungal; Kuijpers-Jagtman, Anne Marie; Kuijpers, Mette A R

    2017-11-01

    Our objective was to develop a photographic setup that would simultaneously capture subjects' smiles from 3 views, both statically and dynamically, and develop a software to crop the produced video clip and slice the frames to study the smile at different stages. Facial images were made of 96 subjects, aged 18 to 28 years, in natural head position using a standardized setup of 3 digital single lens reflex cameras, with a reference sticker (10 × 10 mm) on the forehead of each subject. To test the reproducibility of the setup, 1 operator took 3 images of all subjects on the same day and on 3 different days in a subset of 26 subjects. For the same-day observations, correlation coefficients varied between 0.87 and 0.93. For the observations on 3 different days, correlation coefficients were also high. The duplicate measurement error and the mean difference between measurements were small and not significant, pointing to good reliability. This new technique to capture standardized high-definition video and still images simultaneously from 3 positions is a reliable and practical tool. The technique is easy to learn and implement in the orthodontic office. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  16. PERFORMANCE EVALUATION OF THERMOGRAPHIC CAMERAS FOR PHOTOGRAMMETRIC MEASUREMENTS

    Directory of Open Access Journals (Sweden)

    N. Yastikli

    2013-05-01

    Full Text Available The aim of this research is the performance evaluation of the termographic cameras for possible use for photogrammetric documentation and deformation analyses caused by moisture and isolation problem of the historical and cultural heritage. To perform geometric calibration of the termographic camera, the 3D test object was designed with 77 control points which were distributed in different depths. For performance evaluation, Flir A320 termographic camera with 320 × 240 pixels and lens with 18 mm focal length was used. The Nikon D3X SLR digital camera with 6048 × 4032 pixels and lens with 20 mm focal length was used as reference for comparison. The size of pixel was 25 μm for the Flir A320 termographic camera and 6 μm for the Nikon D3X SLR digital camera. The digital images of the 3D test object were recorded with the Flir A320 termographic camera and Nikon D3X SLR digital camera and the image coordinate of the control points in the images were measured. The geometric calibration parameters, including the focal length, position of principal points, radial and tangential distortions were determined with introduced additional parameters in bundle block adjustments. The measurement of image coordinates and bundle block adjustments with additional parameters were performed using the PHIDIAS digital photogrammetric system. The bundle block adjustment was repeated with determined calibration parameter for both Flir A320 termographic camera and Nikon D3X SLR digital camera. The obtained standard deviation of measured image coordinates was 9.6 μm and 10.5 μm for Flir A320 termographic camera and 8.3 μm and 7.7 μm for Nikon D3X SLR digital camera. The obtained standard deviation of measured image points in Flir A320 termographic camera images almost same accuracy level with digital camera in comparison with 4 times bigger pixel size. The obtained results from this research, the interior geometry of the termographic cameras and lens distortion was

  17. Performance Evaluation of Thermographic Cameras for Photogrammetric Measurements

    Science.gov (United States)

    Yastikli, N.; Guler, E.

    2013-05-01

    The aim of this research is the performance evaluation of the termographic cameras for possible use for photogrammetric documentation and deformation analyses caused by moisture and isolation problem of the historical and cultural heritage. To perform geometric calibration of the termographic camera, the 3D test object was designed with 77 control points which were distributed in different depths. For performance evaluation, Flir A320 termographic camera with 320 × 240 pixels and lens with 18 mm focal length was used. The Nikon D3X SLR digital camera with 6048 × 4032 pixels and lens with 20 mm focal length was used as reference for comparison. The size of pixel was 25 μm for the Flir A320 termographic camera and 6 μm for the Nikon D3X SLR digital camera. The digital images of the 3D test object were recorded with the Flir A320 termographic camera and Nikon D3X SLR digital camera and the image coordinate of the control points in the images were measured. The geometric calibration parameters, including the focal length, position of principal points, radial and tangential distortions were determined with introduced additional parameters in bundle block adjustments. The measurement of image coordinates and bundle block adjustments with additional parameters were performed using the PHIDIAS digital photogrammetric system. The bundle block adjustment was repeated with determined calibration parameter for both Flir A320 termographic camera and Nikon D3X SLR digital camera. The obtained standard deviation of measured image coordinates was 9.6 μm and 10.5 μm for Flir A320 termographic camera and 8.3 μm and 7.7 μm for Nikon D3X SLR digital camera. The obtained standard deviation of measured image points in Flir A320 termographic camera images almost same accuracy level with digital camera in comparison with 4 times bigger pixel size. The obtained results from this research, the interior geometry of the termographic cameras and lens distortion was modelled efficiently

  18. Reflexivity in Narratives on Practice

    DEFF Research Database (Denmark)

    Jakobsen, Helle Nordentoft; Olesen, Lektor Birgitte Ravn

    Previous research has shown how reflexivity is a precondition for knowledge co-production through productive dialogue in organisational contexts because it entails a re-ordering, re-arranging and re-designing of what one knows and therefore creates new angles of vision. In this paper, we draw...... on Bakhtinian dialogic communication theory and discursive psychology to investigate the written practice narratives of 23 students on a Masters Degree Programme in Educational Studies, focusing on how the process of writing narratives accentuates reflexivity. Our findings indicate that the narratives invite...... have the potential to bring about productive learning in organizational contexts since they appear to stimulate participants’ relational engagement and reflexivity....

  19. Reflex Sympathetic Dystrophy in Children

    Directory of Open Access Journals (Sweden)

    Adnan Ayvaz

    2013-10-01

    Full Text Available    Reflex sympathetic dystrophy (chronic regional pain syndrome isn’t frequently encountered in practical pediatrics and childhood. Reflex sympathetic dystrophy syndrome (RSD is a disorder characterized by widespread localized pain, often along with swelling, discoloration, trophic changes and autonomic abnormalities such as vasomotor disorders. Its etio-pathogenesis hasn’t been completely determined.The disease can form in an area innerved by a partially damaged nerve and usually follows minor injury or trauma. In this paper, two girl patients with reflex sympathetic dystrophy are discussed along with the laboratory and clinic finding by accompaniment the literature as it is rarely seen in childhood.

  20. DEFINITION LENS DISTORTION CAMERA WHEN PHOTOGRAMMETRIC IMAGE PROCESSING

    Directory of Open Access Journals (Sweden)

    S. N. Mamedbekov

    2014-01-01

    Full Text Available In this paper we consider the classical method of calculating the magnitude of the distortion, and the account of its impact on the offset image points on the field image. Made a priori estimate of the impact of distortion for lenses with focal lengths of 55 mm and 140 mm. Results given graphically. 

  1. Proprioceptive reflexes in patients with reflex sympathetic dystrophy.

    Science.gov (United States)

    Schouten, A C; Van de Beek, W J T; Van Hilten, J J; Van der Helm, F C T

    2003-07-01

    Reflex sympathetic dystrophy (RSD) is a syndrome that frequently follows an injury and is characterized by sensory, autonomic and motor features of the affected extremities. One of the more common motor features of RSD is tonic dystonia, which is caused by impairment of inhibitory interneuronal spinal circuits. In this study the circuits that modulate the gain of proprioceptive reflexes of the shoulder musculature are quantitatively assessed in 19 RSD patients, 9 of whom presented with dystonia. The proprioceptive reflexes are quantified by applying two types of force disturbances: (1) disturbances with a fixed low frequency and a variable bandwidth and (2) disturbances with a small bandwidth around a prescribed centre frequency. Compared to controls, patients have lower reflex gains for velocity feedback in response to the disturbances around a prescribed centre frequency. Additionally, patients with dystonia lack the ability to generate negative reflex gains for position feedback, for these same disturbances. Proprioceptive reflexes to the disturbances with a fixed low frequency and variable bandwidth present no difference between patients and controls. Although dystonia in the RSD patients was limited to the distal musculature, the results suggest involvement of interneuronal circuits that mediate postsynaptic inhibition of the motoneurons of the proximal musculature.

  2. Curiosity's Mars Hand Lens Imager (MAHLI) Investigation

    Science.gov (United States)

    Edgett, Kenneth S.; Yingst, R. Aileen; Ravine, Michael A.; Caplinger, Michael A.; Maki, Justin N.; Ghaemi, F. Tony; Schaffner, Jacob A.; Bell, James F.; Edwards, Laurence J.; Herkenhoff, Kenneth E.; Heydari, Ezat; Kah, Linda C.; Lemmon, Mark T.; Minitti, Michelle E.; Olson, Timothy S.; Parker, Timothy J.; Rowland, Scott K.; Schieber, Juergen; Sullivan, Robert J.; Sumner, Dawn Y.; Thomas, Peter C.; Jensen, Elsa H.; Simmonds, John J.; Sengstacken, Aaron J.; Wilson, Reg G.; Goetz, Walter

    2012-01-01

    The Mars Science Laboratory (MSL) Mars Hand Lens Imager (MAHLI) investigation will use a 2-megapixel color camera with a focusable macro lens aboard the rover, Curiosity, to investigate the stratigraphy and grain-scale texture, structure, mineralogy, and morphology of geologic materials in northwestern Gale crater. Of particular interest is the stratigraphic record of a ?5 km thick layered rock sequence exposed on the slopes of Aeolis Mons (also known as Mount Sharp). The instrument consists of three parts, a camera head mounted on the turret at the end of a robotic arm, an electronics and data storage assembly located inside the rover body, and a calibration target mounted on the robotic arm shoulder azimuth actuator housing. MAHLI can acquire in-focus images at working distances from ?2.1 cm to infinity. At the minimum working distance, image pixel scale is ?14 μm per pixel and very coarse silt grains can be resolved. At the working distance of the Mars Exploration Rover Microscopic Imager cameras aboard Spirit and Opportunity, MAHLI?s resolution is comparable at ?30 μm per pixel. Onboard capabilities include autofocus, auto-exposure, sub-framing, video imaging, Bayer pattern color interpolation, lossy and lossless compression, focus merging of up to 8 focus stack images, white light and longwave ultraviolet (365 nm) illumination of nearby subjects, and 8 gigabytes of non-volatile memory data storage.

  3. Multiview Trajectory Mapping Using Homography with Lens Distortion Correction

    Directory of Open Access Journals (Sweden)

    Andrea Cavallaro

    2008-11-01

    Full Text Available We present a trajectory mapping algorithm for a distributed camera setting that is based on statistical homography estimation accounting for the distortion introduced by camera lenses. Unlike traditional approaches based on the direct linear transformation (DLT algorithm and singular value decomposition (SVD, the planar homography estimation is derived from renormalization. In addition to this, the algorithm explicitly introduces a correction parameter to account for the nonlinear radial lens distortion, thus improving the accuracy of the transformation. We demonstrate the proposed algorithm by generating mosaics of the observed scenes and by registering the spatial locations of moving objects (trajectories from multiple cameras on the mosaics. Moreover, we objectively compare the transformed trajectories with those obtained by SVD and least mean square (LMS methods on standard datasets and demonstrate the advantages of the renormalization and the lens distortion correction.

  4. Multiview Trajectory Mapping Using Homography with Lens Distortion Correction

    Directory of Open Access Journals (Sweden)

    Kayumbi Gabin

    2008-01-01

    Full Text Available Abstract We present a trajectory mapping algorithm for a distributed camera setting that is based on statistical homography estimation accounting for the distortion introduced by camera lenses. Unlike traditional approaches based on the direct linear transformation (DLT algorithm and singular value decomposition (SVD, the planar homography estimation is derived from renormalization. In addition to this, the algorithm explicitly introduces a correction parameter to account for the nonlinear radial lens distortion, thus improving the accuracy of the transformation. We demonstrate the proposed algorithm by generating mosaics of the observed scenes and by registering the spatial locations of moving objects (trajectories from multiple cameras on the mosaics. Moreover, we objectively compare the transformed trajectories with those obtained by SVD and least mean square (LMS methods on standard datasets and demonstrate the advantages of the renormalization and the lens distortion correction.

  5. Benchmarking the Optical Resolving Power of Uav Based Camera Systems

    Science.gov (United States)

    Meißner, H.; Cramer, M.; Piltz, B.

    2017-08-01

    UAV based imaging and 3D object point generation is an established technology. Some of the UAV users try to address (very) highaccuracy applications, i.e. inspection or monitoring scenarios. In order to guarantee such level of detail and accuracy high resolving imaging systems are mandatory. Furthermore, image quality considerably impacts photogrammetric processing, as the tie point transfer, mandatory for forming the block geometry, fully relies on the radiometric quality of images. Thus, empirical testing of radiometric camera performance is an important issue, in addition to standard (geometric) calibration, which normally is covered primarily. Within this paper the resolving power of ten different camera/lens installations has been investigated. Selected systems represent different camera classes, like DSLRs, system cameras, larger format cameras and proprietary systems. As the systems have been tested in wellcontrolled laboratory conditions and objective quality measures have been derived, individual performance can be compared directly, thus representing a first benchmark on radiometric performance of UAV cameras. The results have shown, that not only the selection of appropriate lens and camera body has an impact, in addition the image pre-processing, i.e. the use of a specific debayering method, significantly influences the final resolving power.

  6. BENCHMARKING THE OPTICAL RESOLVING POWER OF UAV BASED CAMERA SYSTEMS

    Directory of Open Access Journals (Sweden)

    H. Meißner

    2017-08-01

    Full Text Available UAV based imaging and 3D object point generation is an established technology. Some of the UAV users try to address (very highaccuracy applications, i.e. inspection or monitoring scenarios. In order to guarantee such level of detail and accuracy high resolving imaging systems are mandatory. Furthermore, image quality considerably impacts photogrammetric processing, as the tie point transfer, mandatory for forming the block geometry, fully relies on the radiometric quality of images. Thus, empirical testing of radiometric camera performance is an important issue, in addition to standard (geometric calibration, which normally is covered primarily. Within this paper the resolving power of ten different camera/lens installations has been investigated. Selected systems represent different camera classes, like DSLRs, system cameras, larger format cameras and proprietary systems. As the systems have been tested in wellcontrolled laboratory conditions and objective quality measures have been derived, individual performance can be compared directly, thus representing a first benchmark on radiometric performance of UAV cameras. The results have shown, that not only the selection of appropriate lens and camera body has an impact, in addition the image pre-processing, i.e. the use of a specific debayering method, significantly influences the final resolving power.

  7. Active learning in camera calibration through vision measurement application

    Science.gov (United States)

    Li, Xiaoqin; Guo, Jierong; Wang, Xianchun; Liu, Changqing; Cao, Binfang

    2017-08-01

    Since cameras are increasingly more used in scientific application as well as in the applications requiring precise visual information, effective calibration of such cameras is getting more important. There are many reasons why the measurements of objects are not accurate. The largest reason is that the lens has a distortion. Another detrimental influence on the evaluation accuracy is caused by the perspective distortions in the image. They happen whenever we cannot mount the camera perpendicularly to the objects we want to measure. In overall, it is very important for students to understand how to correct lens distortions, that is camera calibration. If the camera is calibrated, the images are rectificated, and then it is possible to obtain undistorted measurements in world coordinates. This paper presents how the students should develop a sense of active learning for mathematical camera model besides the theoretical scientific basics. The authors will present the theoretical and practical lectures which have the goal of deepening the students understanding of the mathematical models of area scan cameras and building some practical vision measurement process by themselves.

  8. [Reflex sympathetic dystrophy].

    Science.gov (United States)

    Oliveira, Marta; Manuela, Manuela; Cantinho, Guilhermina

    2011-01-01

    Reflex Sympathetic Dystrophy is rare in pediatrics. It is a complex regional pain syndrome, of unknown etiology, usually post-traumatic, characterized by dysfunctions of the musculoskeletal, vascular and skin systems: severe persistent pain of a limb, sensory and vascular alterations, associated disability and psychosocial dysfunction. The diagnosis is based in high clinical suspection. In children and adolescents there are aspects that are different from the adult ones. Excessive tests may result in worsening of the clinical symptoms. Bone scintigraphy can help. Pain treatment is difficult, not specific. Physical therapies and relaxation technics give some relief. Depression must be treated. This syndrome includes fibromyalgia and complex regional pain syndrome type I. We present a clinical report of an adolescent girl, referred for pain, cold temperature, pallor and functional disability of an inferior limb, all signals disclosed by a minor trauma. She had been diagnosed depression the year before. The bone scintigraphy was a decisive test. The treatment with gabapentin, C vitamin, physiotherapy and pshycotherapy has been effective.

  9. Volitional control of reflex cough

    Science.gov (United States)

    Bolser, Donald C.; Davenport, Paul W.

    2012-01-01

    Multiple studies suggest a role for the cerebral cortex in the generation of reflex cough in awake humans. Reflex cough is preceded by detection of an urge to cough; strokes specifically within the cerebral cortex can affect parameters of reflex cough, and reflex cough can be voluntarily suppressed. However, it is not known to what extent healthy, awake humans can volitionally modulate the cough reflex, aside from suppression. The aims of this study were to determine whether conscious humans can volitionally modify their reflexive cough and, if so, to determine what parameters of the cough waveform and corresponding muscle activity can be modified. Twenty adults (18–40 yr, 4 men) volunteered for study participation and gave verbal and written informed consent. Participants were seated and outfitted with a facemask and pneumotacograph, and two surface EMG electrodes were positioned over expiratory muscles. Capsaicin (200 μM) was delivered via dosimeter and one-way (inspiratory) valve attached to a side port between the facemask and pneumotachograph. Cough airflow and surface EMG activity were recorded across tasks including 1) baseline, 2) small cough (cough smaller or softer than normal), 3) long cough (cough longer or louder than normal), and 4) not cough (alternative behavior). All participants coughed in response to 200 μM capsaicin and were able to modify the cough. Variables exhibiting changes include those related to the peak airflow during the expiratory phase. Results demonstrate that it is possible to volitionally modify cough motor output characteristics. PMID:22492938

  10. A practical application of photogrammetry to performing rib characterization measurements in an underground coal mine using a DSLR camera.

    Science.gov (United States)

    Slaker, Brent A; Mohamed, Khaled M

    2017-01-01

    Understanding coal mine rib behavior is important for inferring pillar loading conditions as well as ensuring the safety of miners who are regularly exposed to ribs. Due to the variability in the geometry of underground openings and ground behavior, point measurements often fail to capture the true movement of mine workings. Photogrammetry is a potentially fast, cheap, and precise supplemental measurement tool in comparison to extensometers, tape measures, or laser range meters, but its application in underground coal has been limited. The practical use of photogrammetry was tested at the Safety Research Coal Mine, National Institute for Occupational Safety and Health (NIOSH). A commercially available, digital single-lens reflex (DSLR) camera was used to perform the photogrammetric surveys for the experiment. Several experiments were performed using different lighting conditions, distances to subject, camera settings, and photograph overlaps, with results summarized as follows: the lighting method was found to be insignificant if the scene was appropriately illuminated. It was found that the distance to the subject has a minimal impact on result accuracy, and that camera settings have a significant impact on the photogrammetric quality of images. An increasing photograph resolution was preferable when measuring plane orientations; otherwise a high point cloud density would likely be excessive. Focal ratio (F-stop) changes affect the depth of field and image quality in situations where multiple angles are necessary to survey cleat orientations. Photograph overlap is very important to proper three-dimensional reconstruction, and at least 60% overlap between photograph pairs is ideal to avoid unnecessary post-processing. The suggestions and guidelines proposed are designed to increase the quality of photogrammetry inputs and outputs as well as minimize processing time, and serve as a starting point for an underground coal photogrammetry study.

  11. Those Nifty Digital Cameras!

    Science.gov (United States)

    Ekhaml, Leticia

    1996-01-01

    Describes digital photography--an electronic imaging technology that merges computer capabilities with traditional photography--and its uses in education. Discusses how a filmless camera works, types of filmless cameras, advantages and disadvantages, and educational applications of the consumer digital cameras. (AEF)

  12. Adapting Virtual Camera Behaviour

    DEFF Research Database (Denmark)

    Burelli, Paolo

    2013-01-01

    In a three-dimensional virtual environment aspects such as narrative and interaction completely depend on the camera since the camera defines the player’s point of view. Most research works in automatic camera control aim to take the control of this aspect from the player to automatically gen...

  13. Cryogenic solid Schmidt camera as a base for future wide-field IR systems

    Science.gov (United States)

    Yudin, Alexey N.

    2011-11-01

    Work is focused on study of capability of solid Schmidt camera to serve as a wide-field infrared lens for aircraft system with whole sphere coverage, working in 8-14 um spectral range, coupled with spherical focal array of megapixel class. Designs of 16 mm f/0.2 lens with 60 and 90 degrees sensor diagonal are presented, their image quality is compared with conventional solid design. Achromatic design with significantly improved performance, containing enclosed soft correcting lens behind protective front lens is proposed. One of the main goals of the work is to estimate benefits from curved detector arrays in 8-14 um spectral range wide-field systems. Coupling of photodetector with solid Schmidt camera by means of frustrated total internal reflection is considered, with corresponding tolerance analysis. The whole lens, except front element, is considered to be cryogenic, with solid Schmidt unit to be flown by hydrogen for improvement of bulk transmission.

  14. The WEBERSAT camera - An inexpensive earth imaging system

    Science.gov (United States)

    Jackson, Stephen; Raetzke, Jeffrey

    WEBERSAT is a 27 pound LEO satellite launched in 1990 into a 500 mile polar orbit. One of its payloads is a low cost CCD color camera system developed by engineering students at Weber State University. The camera is a modified Canon CI-10 with a 25 mm lens, automatic iris, and 780 x 490 pixel resolution. The iris range control potentiometer was made programmable; a 10.7 MHz digitization clock, fixed focus support, and solid tantalum capacitors were added. Camera output signals, composite video, red, green, blue, and the digitization clock are fed to a flash digitizer, where they are processed for storage in RAM. Camera control commands are stored and executed via the onboard computer. The CCD camera has successfully imaged meteorological features of the earth, land masses, and a number of astronomical objects.

  15. [Cinematography of ocular fundus with a jointed optical system and tv or cine-camera (author's transl)].

    Science.gov (United States)

    Kampik, A; Rapp, J

    1979-02-01

    A method of Cinematography of the ocular fundus is introduced which--by connecting a camera with an indirect ophthalmoscop--allows to record the monocular picture of the fundus as produced by the ophthalmic lens.

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... new application of artificial intelligence shows whether a patient’s eyes point to high blood pressure or risk ...

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... be purchased over-the-counter or on the Internet," says Thomas Steinemann, MD, professor of ophthalmology at ... ask for a prescription. There is no such thing as a "one size fits all" contact lens. ...

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... had not been properly fitted by an eye care professional, the lenses stuck to my eye like ... lenses do not require the same level of care or consideration as a standard contact lens because ...

  19. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her ...

  20. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... Costume Contact Lenses Can Ruin Vision Eye Makeup Safety In fact, it is illegal to sell colored ...

  1. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... with Colored Contact Lenses Julian: Teenager Blinded In One Eye By Non-Prescription Contact Lens Laura: Vision ... Robyn: Blurry Vision and Daily Eye Drops After One Use Facts About Colored Contacts and Halloween Safety ...

  2. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of Service For ...

  3. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... in a pair of colored contact lenses, Laura Butler of Parkersburg, W.Va., had "extreme pain in ... to wear any kind of contact lens. In Butler's case, the lenses caused an infection and left ...

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses ...

  5. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... an impulsive buy from a souvenir shop, but 10 hours after she first put in a pair ... Prescription Contact Lens Laura: Vision Loss After Just 10 Hours Robyn: Blurry Vision and Daily Eye Drops ...

  6. bubble chamber lens

    CERN Multimedia

    Before the days of electronic detectors, visual techniques were used to detect particles, using detectors such as spark chambers and bubble chambers. This plexiglass lens was used to focus the image of tracks so they could be photographed.

  7. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Contact Lens Facts Over-the-Counter Costume Contacts May Contain Chemicals Harmful to Eyes Four Ways Over- ... without a prescription are breaking the law, and may be fined $11,000 per violation. "Many of ...

  8. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... not require the same level of care or consideration as a standard contact lens because they can ... sell contacts without a prescription are breaking the law, and may be fined $11,000 per violation. " ...

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... an ophthalmologist — an eye medical doctor — who will measure each eye and talk to you about proper ...

  10. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. Follow the contact lens care directions for cleaning, disinfecting, and wearing the lenses. Never share contact ... with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  11. Viscous froth lens

    Science.gov (United States)

    Green, T. E.; Bramley, A.; Lue, L.; Grassia, P.

    2006-11-01

    Microscale models of foam structure traditionally incorporate a balance between bubble pressures and surface tension forces associated with curvature of bubble films. In particular, models for flowing foam microrheology have assumed this balance is maintained under the action of some externally imposed motion. Recently, however, a dynamic model for foam structure has been proposed, the viscous froth model, which balances the net effect of bubble pressures and surface tension to viscous dissipation forces: this permits the description of fast-flowing foam. This contribution examines the behavior of the viscous froth model when applied to a paradigm problem with a particularly simple geometry: namely, a two-dimensional bubble “lens.” The lens consists of a channel partly filled by a bubble (known as the “lens bubble”) which contacts one channel wall. An additional film (known as the “spanning film”) connects to this bubble spanning the distance from the opposite channel wall. This simple structure can be set in motion and deformed out of equilibrium by applying a pressure across the spanning film: a rich dynamical behavior results. Solutions for the lens structure steadily propagating along the channel can be computed by the viscous froth model. Perturbation solutions are obtained in the limit of a lens structure with weak applied pressures, while numerical solutions are available for higher pressures. These steadily propagating solutions suggest that small lenses move faster than large ones, while both small and large lens bubbles are quite resistant to deformation, at least for weak applied back pressures. As the applied back pressure grows, the structure with the small lens bubble remains relatively stiff, while that with the large lens bubble becomes much more compliant. However, with even further increases in the applied back pressure, a critical pressure appears to exist for which the steady-state structure loses stability and unsteady

  12. INFLUENCE OF MECHANICAL ERRORS IN A ZOOM CAMERA

    Directory of Open Access Journals (Sweden)

    Alfredo Gardel

    2011-05-01

    Full Text Available As it is well known, varying the focus and zoom of a camera lens system changes the alignment of the lens components resulting in a displacement of the image centre and field of view. Thus, knowledge of how the image centre shifts may be important for some aspects of camera calibration. As shown in other papers, the pinhole model is not adequate for zoom lenses. To ensure a calibration model for these lenses, the calibration parameters must be adjusted. The geometrical modelling of a zoom lens is realized from its lens specifications. The influence on the calibration parameters is calculated by introducing mechanical errors in the mobile lenses. Figures are given describing the errors obtained in the principal point coordinates and also in its standard deviation. A comparison is then made with the errors that come from the incorrect detection of the calibration points. It is concluded that mechanical errors of actual zoom lenses can be neglected in the calibration process because detection errors have more influence on the camera parameters.

  13. A Portable, Inexpensive, Nonmydriatic Fundus Camera Based on the Raspberry Pi® Computer.

    Science.gov (United States)

    Shen, Bailey Y; Mukai, Shizuo

    2017-01-01

    Purpose. Nonmydriatic fundus cameras allow retinal photography without pharmacologic dilation of the pupil. However, currently available nonmydriatic fundus cameras are bulky, not portable, and expensive. Taking advantage of recent advances in mobile technology, we sought to create a nonmydriatic fundus camera that was affordable and could be carried in a white coat pocket. Methods. We built a point-and-shoot prototype camera using a Raspberry Pi computer, an infrared-sensitive camera board, a dual infrared and white light light-emitting diode, a battery, a 5-inch touchscreen liquid crystal display, and a disposable 20-diopter condensing lens. Our prototype camera was based on indirect ophthalmoscopy with both infrared and white lights. Results. The prototype camera measured 133mm × 91mm × 45mm and weighed 386 grams. The total cost of the components, including the disposable lens, was $185.20. The camera was able to obtain good-quality fundus images without pharmacologic dilation of the pupils. Conclusion. A fully functional, inexpensive, handheld, nonmydriatic fundus camera can be easily assembled from a relatively small number of components. With modest improvements, such a camera could be useful for a variety of healthcare professionals, particularly those who work in settings where a traditional table-mounted nonmydriatic fundus camera would be inconvenient.

  14. A Portable, Inexpensive, Nonmydriatic Fundus Camera Based on the Raspberry Pi® Computer

    Directory of Open Access Journals (Sweden)

    Bailey Y. Shen

    2017-01-01

    Full Text Available Purpose. Nonmydriatic fundus cameras allow retinal photography without pharmacologic dilation of the pupil. However, currently available nonmydriatic fundus cameras are bulky, not portable, and expensive. Taking advantage of recent advances in mobile technology, we sought to create a nonmydriatic fundus camera that was affordable and could be carried in a white coat pocket. Methods. We built a point-and-shoot prototype camera using a Raspberry Pi computer, an infrared-sensitive camera board, a dual infrared and white light light-emitting diode, a battery, a 5-inch touchscreen liquid crystal display, and a disposable 20-diopter condensing lens. Our prototype camera was based on indirect ophthalmoscopy with both infrared and white lights. Results. The prototype camera measured 133mm×91mm×45mm and weighed 386 grams. The total cost of the components, including the disposable lens, was $185.20. The camera was able to obtain good-quality fundus images without pharmacologic dilation of the pupils. Conclusion. A fully functional, inexpensive, handheld, nonmydriatic fundus camera can be easily assembled from a relatively small number of components. With modest improvements, such a camera could be useful for a variety of healthcare professionals, particularly those who work in settings where a traditional table-mounted nonmydriatic fundus camera would be inconvenient.

  15. Radiation camera exposure control

    International Nuclear Information System (INIS)

    Martone, R.J.; Yarsawich, M.; Wolczek, W.

    1976-01-01

    A system and method for governing the exposure of an image generated by a radiation camera to an image sensing camera is disclosed. The exposure is terminated in response to the accumulation of a predetermined quantity of radiation, defining a radiation density, occurring in a predetermined area. An index is produced which represents the value of that quantity of radiation whose accumulation causes the exposure termination. The value of the predetermined radiation quantity represented by the index is sensed so that the radiation camera image intensity can be calibrated to compensate for changes in exposure amounts due to desired variations in radiation density of the exposure, to maintain the detectability of the image by the image sensing camera notwithstanding such variations. Provision is also made for calibrating the image intensity in accordance with the sensitivity of the image sensing camera, and for locating the index for maintaining its detectability and causing the proper centering of the radiation camera image

  16. CALIBRATION PROCEDURES ON OBLIQUE CAMERA SETUPS

    Directory of Open Access Journals (Sweden)

    G. Kemper

    2016-06-01

    Full Text Available Beside the creation of virtual animated 3D City models, analysis for homeland security and city planning, the accurately determination of geometric features out of oblique imagery is an important task today. Due to the huge number of single images the reduction of control points force to make use of direct referencing devices. This causes a precise camera-calibration and additional adjustment procedures. This paper aims to show the workflow of the various calibration steps and will present examples of the calibration flight with the final 3D City model. In difference to most other software, the oblique cameras are used not as co-registered sensors in relation to the nadir one, all camera images enter the AT process as single pre-oriented data. This enables a better post calibration in order to detect variations in the single camera calibration and other mechanical effects. The shown sensor (Oblique Imager is based o 5 Phase One cameras were the nadir one has 80 MPIX equipped with a 50 mm lens while the oblique ones capture images with 50 MPix using 80 mm lenses. The cameras are mounted robust inside a housing to protect this against physical and thermal deformations. The sensor head hosts also an IMU which is connected to a POS AV GNSS Receiver. The sensor is stabilized by a gyro-mount which creates floating Antenna –IMU lever arms. They had to be registered together with the Raw GNSS-IMU Data. The camera calibration procedure was performed based on a special calibration flight with 351 shoots of all 5 cameras and registered the GPS/IMU data. This specific mission was designed in two different altitudes with additional cross lines on each flying heights. The five images from each exposure positions have no overlaps but in the block there are many overlaps resulting in up to 200 measurements per points. On each photo there were in average 110 well distributed measured points which is a satisfying number for the camera calibration. In a first

  17. Solid state video cameras

    CERN Document Server

    Cristol, Y

    2013-01-01

    Solid State Video Cameras reviews the state of the art in the field of solid-state television cameras as compiled from patent literature. Organized into 10 chapters, the book begins with the basic array types of solid-state imagers and appropriate read-out circuits and methods. Documents relating to improvement of picture quality, such as spurious signal suppression, uniformity correction, or resolution enhancement, are also cited. The last part considerssolid-state color cameras.

  18. Two ways to support reflexivity

    DEFF Research Database (Denmark)

    Adriansen, Hanne Kirstine; Knudsen, Hanne

    2013-01-01

    A current challenge to public managers is the lack of a well-defined role. How can master’s programmes prepare managers to live up to an undefined function? In this paper we argue that the lack of role description enhances the need for reflexivity and show how it is done at Master in Educational......’. This requires participants to conduct experiments in their own organization, to reflect on and analyse their experiences with concepts from the curriculum. While the new language and the experimental teaching format are difficult, the participants learn a reflexive practice that can enable them to life up...

  19. Outside home. Notes on reflexivity

    Directory of Open Access Journals (Sweden)

    Mara Clemente

    2017-01-01

    The paper proffers the idea in which a “reflexive process” on subjectivity can involve and/or hopefully involve the entire experience of the researcher, going beyond the borders of a single research. In the process, unexpected elements of subjectivity can come into play; in other cases the meaning attributed to them can change in time or can have a role different from what had been expected. Some elements, objects of epistemological analyses, as imposed by a reflexive approach, can become objects of attention also on the phenomenological level.

  20. Educating the Reflexive Practitioner

    Directory of Open Access Journals (Sweden)

    Marc J. Neveu

    2012-09-01

    wearing any clothes.Notwithstanding such issues, I do believe the studio holds the potentialto be an empowering learning experience. The intention of this article is to question the mode of instruction in an architectural studio. I’ve structured the paper in three parts. First, I will briefly describe the findingsof the study made by the Carnegie Foundation for the Advancementof Teaching known as the Boyer Report.2 To develop and support the findings of the Boyer Report, I introduce the work of the educator Donald Schön. Though I see much merit in the Boyer Report, and Schön’sproposals, I argue that a more nuanced approach is required. I will recommend, therefore, in the second section of this paper that a meansof architectural education as based on the Socratic method may be amore productive approach. My reading of the Socratic method is basedprimarily on early Socratic dialogues and I will specifically use Charmidesto illustrate the issues that I believe are relevant to studio pedagogy.3 From my analysis of Charmides I will, in the third section of the essay,describe how the Socratic method is beneficial to studio pedagogy threeways: reflexive, non-propositional, and finally how Socrates’ approachmay indeed be practical. This last section will be illustrated with a studentproject. It is my conjecture that the Socratic method offers insight intocurrent discussions of educational theory, namely student-centered,project-based learning.

  1. LSST Camera Optics Design

    Energy Technology Data Exchange (ETDEWEB)

    Riot, V J; Olivier, S; Bauman, B; Pratuch, S; Seppala, L; Gilmore, D; Ku, J; Nordby, M; Foss, M; Antilogus, P; Morgado, N

    2012-05-24

    The Large Synoptic Survey Telescope (LSST) uses a novel, three-mirror, telescope design feeding a camera system that includes a set of broad-band filters and three refractive corrector lenses to produce a flat field at the focal plane with a wide field of view. Optical design of the camera lenses and filters is integrated in with the optical design of telescope mirrors to optimize performance. We discuss the rationale for the LSST camera optics design, describe the methodology for fabricating, coating, mounting and testing the lenses and filters, and present the results of detailed analyses demonstrating that the camera optics will meet their performance goals.

  2. CALIBRATION OF LOW COST RGB AND NIR UAV CAMERAS

    Directory of Open Access Journals (Sweden)

    A. Fryskowska

    2016-06-01

    Full Text Available Non-metric digital cameras are being widely used for photogrammetric studies. The increase in resolution and quality of images obtained by non-metric cameras, allows to use it in low-cost UAV and terrestrial photogrammetry. Imagery acquired with non-metric cameras can be used in 3D modeling of objects or landscapes, reconstructing of historical sites, generating digital elevation models (DTM, orthophotos, or in the assessment of accidents. Non-metric digital camcorders are characterized by instability and ignorance of the interior orientation parameters. Therefore, the use of these devices requires prior calibration. Calibration research was conducted using non-metric camera, different calibration tests and various software. The first part of the paper contains a brief theoretical introduction including the basic definitions, like the construction of non-metric cameras or description of different optical distortions. The second part of the paper contains cameras calibration process, details of the calibration methods and models that have been used. Sony Nex 5 camera calibration has been done using software: Image Master Calib, Matlab - Camera Calibrator application and Agisoft Lens. For the study 2D test fields has been used. As a part of the research a comparative analysis of the results have been done.

  3. Calibration of Low Cost RGB and NIR Uav Cameras

    Science.gov (United States)

    Fryskowska, A.; Kedzierski, M.; Grochala, A.; Braula, A.

    2016-06-01

    Non-metric digital cameras are being widely used for photogrammetric studies. The increase in resolution and quality of images obtained by non-metric cameras, allows to use it in low-cost UAV and terrestrial photogrammetry. Imagery acquired with non-metric cameras can be used in 3D modeling of objects or landscapes, reconstructing of historical sites, generating digital elevation models (DTM), orthophotos, or in the assessment of accidents. Non-metric digital camcorders are characterized by instability and ignorance of the interior orientation parameters. Therefore, the use of these devices requires prior calibration. Calibration research was conducted using non-metric camera, different calibration tests and various software. The first part of the paper contains a brief theoretical introduction including the basic definitions, like the construction of non-metric cameras or description of different optical distortions. The second part of the paper contains cameras calibration process, details of the calibration methods and models that have been used. Sony Nex 5 camera calibration has been done using software: Image Master Calib, Matlab - Camera Calibrator application and Agisoft Lens. For the study 2D test fields has been used. As a part of the research a comparative analysis of the results have been done.

  4. Raspberry Pi camera with intervalometer used as crescograph

    Science.gov (United States)

    Albert, Stefan; Surducan, Vasile

    2017-12-01

    The intervalometer is an attachment or facility on a photo-camera that operates the shutter regularly at set intervals over a period. Professional cameras with built in intervalometers are expensive and quite difficult to find. The Canon CHDK open source operating system allows intervalometer implementation on Canon cameras only. However finding a Canon camera with near infra-red (NIR) photographic lens at affordable price is impossible. On experiments requiring several cameras (used to measure growth in plants - the crescographs, but also for coarse evaluation of the water content of leaves), the costs of the equipment are often over budget. Using two Raspberry Pi modules each equipped with a low cost NIR camera and a WIFI adapter (for downloading pictures stored on the SD card) and some freely available software, we have implemented two low budget intervalometer cameras. The shutting interval, the number of pictures to be taken, image resolution and some other parameters can be fully programmed. Cameras have been in use continuously for three months (July-October 2017) in a relevant environment (outside), proving the concept functionality.

  5. Soleus stretch reflex during cycling

    DEFF Research Database (Denmark)

    Grey, Michael James; Pierce, C. W.; Milner, T. E.

    2001-01-01

    The modulation and strength of the human soleus short latency stretch reflex was investigated by mechanically perturbing the ankle during an unconstrained pedaling task. Eight subjects pedaled at 60 rpm against a preload of 10 Nm. A torque pulse was applied to the crank at various positions durin...

  6. Reflexive fatherhood in everyday life

    DEFF Research Database (Denmark)

    Westerling, Allan

    2015-01-01

    This article looks at fathering practices in Denmark, using the findings from a research project on everyday family life in Denmark. It takes a social psychological perspective and employs discursive psychology and theories about reflexive modernisation. It shows how fathers orient towards intima...

  7. The reflexive case study method

    DEFF Research Database (Denmark)

    Rittenhofer, Iris

    2015-01-01

    This paper extends the international business research on small to medium-sized enterprises (SME) at the nexus of globalization. Based on a conceptual synthesis across disciplines and theoretical perspectives, it offers management research a reflexive method for case study research of postnational...

  8. Ultrasound imaging of sacral reflexes

    NARCIS (Netherlands)

    de Jong, Tom P. V. M.; Klijn, Aart J.; Vijverberg, Marianne A. W.; de Kort, Laetitia M. O.

    2006-01-01

    To investigate the reliability of examination of the guarding reflex of the pelvic floor by dynamic perineal ultrasonography in children with bladder dysfunction and in controls. A total of 40 patients with nonneurogenic bladder/sphincter dyssynergia, 40 with spina bifida, and 40 controls underwent

  9. Thermal Cameras and Applications

    DEFF Research Database (Denmark)

    Gade, Rikke; Moeslund, Thomas B.

    2014-01-01

    Thermal cameras are passive sensors that capture the infrared radiation emitted by all objects with a temperature above absolute zero. This type of camera was originally developed as a surveillance and night vision tool for the military, but recently the price has dropped, significantly opening up...

  10. A catoptric lens

    International Nuclear Information System (INIS)

    Rambauske, W.R.

    1973-01-01

    The invention relates to a catoptric lens for combining energies transmitted by several sources such as lasers; said lens comprising mirrors, the reflective surfaces of which have their focuses spaced from a common axis of symmetry. By means of these reflecting surfaces, which are generated by the nutation of portions of quadratic conics about the axis of symmetry, it is possible to focus the energy emmited by several lasers at the focus of the exit-mirror reflecting surface. This can be applied to thermonuclear fusion [fr

  11. Development of high precision and cryogenic lens holders

    Science.gov (United States)

    Reutlinger, A.; Boesz, Anton; Mottaghibonab, A.; Eckert, P.; Dubowy, M.; Gebler, H.; Grupp, F.; Geis, N.; Bode, A.; Katterloher, R.; Bender, R.

    2017-11-01

    The optical system of the Near Infrared Spectrometer and Photometer (NISP) of the EUCLID mission consists mainly of a filter and grism wheel and 4 aspherical lenses with large diameters up to 170 mm. The single lenses require a high precision positioning at the operational temperature of 150 K. An additional design driver represents the CaF2 material of a lens, which is very sensitive wrt brittleness. The technical maturity of the combination of single features such as CaF2, large diameter (and mass), high precision and cryogenic conditions is considered as low. Therefore, a dedicated pre-development program has been launched to design and develop a first prototype of lens holder and to demonstrate the functional performance at representative operational conditions. The 4 lenses are divided into 3x lenses for the Camera Lens Assembly (CaLA) and 1x lens for the Corrector Lens Assembly (CoLA). Each lens is glue mounted onto solid state springs, part of an adaption ring. The adaption ring shall provide protection against vibration loads, high accuracy positioning, as well as quasi load free mounting of the lens under operational conditions. To reduce thermomechanical loads on the lens, the CTE of the adaption ring is adapted to that of the lens. The glue between lens and solid state spring has to withstand high tension loads during vibration. At the operational temperature the deviating CTE between glue and lens/adaption ring introduces shear loads into the glue interface, which are critical, in particular for the fragile CaF2 lens material. For the case of NISP the shear loads are controlled with the glue pad diameter and the glue thickness. In the context of the development activity many technology aspects such as various solid state spring designs, glue selection and glue handling have been investigated. A parametric structural model was developed to derive the specific design feature of each ring, such as spring force, number of springs, eigenfrequency, etc. This

  12. Camera Trajectory fromWide Baseline Images

    Science.gov (United States)

    Havlena, M.; Torii, A.; Pajdla, T.

    2008-09-01

    Camera trajectory estimation, which is closely related to the structure from motion computation, is one of the fundamental tasks in computer vision. Reliable camera trajectory estimation plays an important role in 3D reconstruction, self localization, and object recognition. There are essential issues for a reliable camera trajectory estimation, for instance, choice of the camera and its geometric projection model, camera calibration, image feature detection and description, and robust 3D structure computation. Most of approaches rely on classical perspective cameras because of the simplicity of their projection models and ease of their calibration. However, classical perspective cameras offer only a limited field of view, and thus occlusions and sharp camera turns may cause that consecutive frames look completely different when the baseline becomes longer. This makes the image feature matching very difficult (or impossible) and the camera trajectory estimation fails under such conditions. These problems can be avoided if omnidirectional cameras, e.g. a fish-eye lens convertor, are used. The hardware which we are using in practice is a combination of Nikon FC-E9 mounted via a mechanical adaptor onto a Kyocera Finecam M410R digital camera. Nikon FC-E9 is a megapixel omnidirectional addon convertor with 180° view angle which provides images of photographic quality. Kyocera Finecam M410R delivers 2272×1704 images at 3 frames per second. The resulting combination yields a circular view of diameter 1600 pixels in the image. Since consecutive frames of the omnidirectional camera often share a common region in 3D space, the image feature matching is often feasible. On the other hand, the calibration of these cameras is non-trivial and is crucial for the accuracy of the resulting 3D reconstruction. We calibrate omnidirectional cameras off-line using the state-of-the-art technique and Mičušík's two-parameter model, that links the radius of the image point r to the

  13. Holographic interferometry using a digital photo-camera

    International Nuclear Information System (INIS)

    Sekanina, H.; Hledik, S.

    2001-01-01

    The possibilities of running digital holographic interferometry using commonly available compact digital zoom photo-cameras are studied. The recently developed holographic setup, suitable especially for digital photo-cameras equipped with an un detachable object lens, is used. The method described enables a simple and straightforward way of both recording and reconstructing of a digital holographic interferograms. The feasibility of the new method is verified by digital reconstruction of the interferograms acquired, using a numerical code based on the fast Fourier transform. Experimental results obtained are presented and discussed. (authors)

  14. Advances in pediatric gastroenterology: introducing video camera capsule endoscopy.

    Science.gov (United States)

    Siaw, Emmanuel O

    2006-04-01

    The video camera capsule endoscope is a gastrointestinal endoscope approved by the U.S. Food and Drug Administration in 2001 for use in diagnosing gastrointestinal disorders in adults. In 2003, the agency approved the device for use in children ages 10 and older, and the endoscope is currently in use at Arkansas Children's Hospital. A capsule camera, lens, battery, transmitter and antenna together record images of the small intestine as the endoscope makes its way through the bowel. The instrument is used with minimal risk to the patient while offering a high degree of accuracy in diagnosing small intestine disorders.

  15. Quadrupole magnetic lens

    International Nuclear Information System (INIS)

    Piskunov, V.A.

    1981-01-01

    The following connection of windings of electromagnet is suggested for simplification of the design of qUadrupole magnetic lens intended for use in radiotechnical and electron-optical devices. The mentioned windings are connected with each other by a bridge scheme and the variable resistors are switched in its diagonals in the lens containing four electromagnet with windings connected with two variable resistors the mobile contacts of which are connected with a direct current source. Current redistribution between left windings and right windings takes place at shift of mobile contact of variable resistor, and current redistribution between upper and low coils of electromagnets takes place at shifting mobile contact of the other variable resistor. In this case smooth and independent electron-optical misalignment of lens by two mutually perpendicular directions proceeds. Use of the given design of the lens in the oscillograph permits to use printing assembly for alignment plate and to reduce the number of connections at the expense of decreasing the number of resistors

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. There is no such thing as a "one size fits all" contact lens. Lenses that are not properly fitted may scratch the eye or cause blood vessels to grow into the cornea. Even if you have perfect vision, you need to get an eye exam and a prescription ...

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Ophthalmologist Patient Stories Español Eye Health / News Halloween Hazard: The Hidden Dangers of Buying Decorative Contact Lenses ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ...

  18. MISSING: BUBBLE CHAMBER LENS

    CERN Multimedia

    2001-01-01

    Would the person who borrowed the large bubble chamber lens from the Microcosm workshops on the ISR please return it. This is a much used piece from our object archives. If anybody has any information about the whereabouts of this object, please contact Emma.Sanders@cern.ch Thank you

  19. The Lens of Chemistry

    Science.gov (United States)

    Thalos, Mariam

    2013-01-01

    Chemistry possesses a distinctive theoretical lens--a distinctive set of theoretical concerns regarding the dynamics and transformations of a perplexing variety of organic and nonorganic substances--to which it must be faithful. Even if it is true that chemical facts bear a special (reductive) relationship to physical facts, nonetheless it will…

  20. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... wear any kind of contact lens. In Butler's case, the lenses caused an infection and left her with a corneal ... A recent article from U.S. News and World Report explains what ophthalmologists are and how they can ...

  1. bubble chamber lens

    CERN Multimedia

    Was used in a PS experiment. Before the days of electronic detectors, visual techniques were used to detect particles, using detectors such as spark chambers and bubble chambers. This plexiglass lens was used to focus the image of tracks so they could be photographed.

  2. Thermal Lens Microscope

    Science.gov (United States)

    Uchiyama, Kenji; Hibara, Akihide; Kimura, Hiroko; Sawada, Tsuguo; Kitamori, Takehiko

    2000-09-01

    We developed a novel laser microscope based on the thermal lens effect induced by a coaxial beam comprised of excitation and probe beams. The signal generation mechanism was confirmed to be an authentic thermal lens effect from the measurement of signal and phase dependences on optical configurations between the sample and the probe beam focus, and therefore, the thermal lens effect theory could be applied. Two-point spatial resolution was determined by the spot size of the excitation beam, not by the thermal diffusion length. Sensitivity was quite high, and the detection ability, evaluated using a submicron microparticle containing dye molecules, was 0.8 zmol/μm2, hence a distribution image of trace chemical species could be obtained quantitatively. In addition, analytes are not restricted to fluorescent species, therefore, the thermal lens microscope is a promising analytical microscope. A two-dimensional image of a histamine molecule distribution, which was produced in mast cells at the femtomole level in a human nasal mucous polyp, was obtained.

  3. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... an Ophthalmologist Patient Stories Español Eye Health / News Halloween Hazard: The Hidden Dangers of Buying Decorative Contact ... After One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter ...

  4. Clinical survey of lens care in contact lens patients.

    Science.gov (United States)

    Ky, W; Scherick, K; Stenson, S

    1998-10-01

    Overall, contact lenses provide a safe and effective modality for vision correction. However, problems do occasionally arise. Up to 80% of contact lens complications can be traced to poor patient compliance with recommended lens care guidelines. We conducted a survey to evaluate the level of patient compliance in specific areas of lens care and maintenance and to assess patient knowledge of basic contact lens information. Patients were asked to complete an anonymous 15 question survey that focused on lens care--specifically the use of contact lens cleaners, methods of disinfection, enzyme treatments, use of rewetting drops, and the frequency of follow-up exams. In addition, the survey included six true/false questions relating to contact lens care and safety. There were a total of 103 participants in the study. Approximately 24% of patients stated they never cleaned their lenses prior to disinfection, and 5% used saline solutions as their primary mode of disinfection. A sizable portion of those surveyed (43% of soft lens wearers and 71% of rigid gas permeable lens wearers) either never used enzyme cleaners or used them less than once a month. Seventy percent of patients either never used rewetting drops or used them less than once a day. Twenty-nine percent of patients consulted their eye care professionals every 2 years and 6% less often than every two years. Six questions assessed patient knowledge of contact lens care safety. Of a possible six out of six correct answers, the mean number of correct responses was 3.74. A sizable proportion of contact lens wearers do not adequately adhere to recommended contact lens care, and many have an inadequate understanding of contact lens care guidelines. Therefore, it is important that practitioners place more emphasis on patient education at the time of initial contact lens fitting and reinforce such instruction during follow-up visits.

  5. Educational Applications for Digital Cameras.

    Science.gov (United States)

    Cavanaugh, Terence; Cavanaugh, Catherine

    1997-01-01

    Discusses uses of digital cameras in education. Highlights include advantages and disadvantages, digital photography assignments and activities, camera features and operation, applications for digital images, accessory equipment, and comparisons between digital cameras and other digitizers. (AEF)

  6. Integrating Reflexivity in Livelihoods Research

    DEFF Research Database (Denmark)

    Prowse, Martin

    2010-01-01

    Much poverty and development research is not explicit about its methodology or philosophical foundations. Based on the extended case method of Burawoy and the epistemological standpoint of critical realism, this paper discusses a methodological approach for reflexive inductive livelihoods researc...... that overcomes the unproductive social science dualism of positivism and social constructivism. The approach is linked to a conceptual framework and a menu of research methods that can be sequenced and iterated in light of research questions....

  7. Being reflexive in qualitative grounded theory: discussion and application of a model of reflexivity.

    Science.gov (United States)

    Engward, Hilary; Davis, Geraldine

    2015-07-01

    A discussion of the meaning of reflexivity in research with the presentation of examples of how a model of reflexivity was used in a grounded theory research project. Reflexivity requires the researcher to make transparent the decisions they make in the research process and is therefore important in developing quality in nursing research. The importance of being reflexive is highlighted in the literature in relation to nursing research, however, practical guidance as to how to go about doing research reflexively is not always clearly articulated. This is a discussion paper. The concept of reflexivity in research is explored using the Alvesson and Skoldberg model of reflexivity and practical examples of how a researcher developed reflexivity in a grounded theory project are presented. Nurse researchers are encouraged to explore and apply the concept of reflexivity in their research practices to develop transparency in the research process and to increase robustness in their research. The Alvesson and Skoldberg model is of value in applying reflexivity in qualitative nursing research, particularly in grounded theory research. Being reflexive requires the researcher to be completely open about decisions that are made in the research process. The Alvesson and Skolberg model of reflexivity is a useful model that can enhance reflexivity in the research process. It can be a useful practical tool to develop reflexivity in grounded theory research. © 2015 John Wiley & Sons Ltd.

  8. The laser scanning camera

    International Nuclear Information System (INIS)

    Jagger, M.

    The prototype development of a novel lenseless camera is reported which utilises a laser beam scanned in a raster by means of orthogonal vibrating mirrors to illuminate the field of view. Laser light reflected from the scene is picked up by a conveniently sited photosensitive device and used to modulate the brightness of a T.V. display scanned in synchronism with the moving laser beam, hence producing a T.V. image of the scene. The camera which needs no external lighting system can act in either a wide angle mode or by varying the size and position of the raster can be made to zoom in to view in detail any object within a 40 0 overall viewing angle. The resolution and performance of the camera are described and a comparison of these aspects is made with conventional T.V. cameras. (author)

  9. Advanced CCD camera developments

    Energy Technology Data Exchange (ETDEWEB)

    Condor, A. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    Two charge coupled device (CCD) camera systems are introduced and discussed, describing briefly the hardware involved, and the data obtained in their various applications. The Advanced Development Group Defense Sciences Engineering Division has been actively designing, manufacturing, fielding state-of-the-art CCD camera systems for over a decade. These systems were originally developed for the nuclear test program to record data from underground nuclear tests. Today, new and interesting application for these systems have surfaced and development is continuing in the area of advanced CCD camera systems, with the new CCD camera that will allow experimenters to replace film for x-ray imaging at the JANUS, USP, and NOVA laser facilities.

  10. Reflex syncope: Diagnosis and treatment

    Directory of Open Access Journals (Sweden)

    Richard Sutton

    2017-12-01

    Full Text Available For the diagnosis of reflex syncope, diligent history-building with the patient and a witness is required. In the Emergency Department (ED, the assessment of syncope is a challenge which may be addressed by an ED Observation Unit or by a referral to a Syncope Unit. Hospital admission is necessary for those with life-threatening cardiac conditions although risk stratification remains an unsolved problem. Other patients may be investigated with less urgency by carotid sinus massage (>40 years, tilt testing, and electrocardiogram loop recorder insertion resulting in a clear cause for syncope. Management includes, in general terms, patient education, avoidance of circumstances in which syncope is likely, increase in fluid and salt consumption, and physical counter-pressure maneuvers. In older patients, those that will benefit from cardiac pacing are now well defined. In all patients, the benefit of drug therapy is often disappointing and there remains no ideal drug. A role for catheter ablation may emerge for the highly symptomatic reflex syncope patient. Keywords: Cardiac pacing, Catheter ablation, Diagnosis, Drugs, Management, Reflex syncope

  11. Night sky quality monitoring in existing and planned dark sky parks by digital cameras

    Directory of Open Access Journals (Sweden)

    Zoltán Kolláth

    2017-06-01

    Full Text Available A crucial part of the qualification of international dark sky places (IDSPs is the objective measurement of night time sky luminance or radiance. Modern digital cameras provide an alternative way to perform all sky imaging either by a fisheye lens or by a mosaic image taken by a wide angle lens. Here we present a method for processing raw camera images to obtain calibrated measurements of sky quality. The comparison of the night sky quality of different European locations is also presented to demonstrate the use of our technique.

  12. Gamma camera system

    International Nuclear Information System (INIS)

    Miller, D.W.; Gerber, M.S.; Schlosser, P.A.; Steidley, J.W.

    1980-01-01

    A detailed description is given of a novel gamma camera which is designed to produce superior images than conventional cameras used in nuclear medicine. The detector consists of a solid state detector (e.g. germanium) which is formed to have a plurality of discrete components to enable 2-dimensional position identification. Details of the electronic processing circuits are given and the problems and limitations introduced by noise are discussed in full. (U.K.)

  13. The Circular Camera Movement

    DEFF Research Database (Denmark)

    Hansen, Lennard Højbjerg

    2014-01-01

    It has been an accepted precept in film theory that specific stylistic features do not express specific content. Nevertheless, it is possible to find many examples in the history of film in which stylistic features do express specific content: for instance, the circular camera movement is used re...... such as the circular camera movement. Keywords: embodied perception, embodied style, explicit narration, interpretation, style pattern, television style...

  14. Neutron cameras for ITER

    International Nuclear Information System (INIS)

    Johnson, L.C.; Barnes, C.W.; Batistoni, P.

    1998-01-01

    Neutron cameras with horizontal and vertical views have been designed for ITER, based on systems used on JET and TFTR. The cameras consist of fan-shaped arrays of collimated flight tubes, with suitably chosen detectors situated outside the biological shield. The sight lines view the ITER plasma through slots in the shield blanket and penetrate the vacuum vessel, cryostat, and biological shield through stainless steel windows. This paper analyzes the expected performance of several neutron camera arrangements for ITER. In addition to the reference designs, the authors examine proposed compact cameras, in which neutron fluxes are inferred from 16 N decay gammas in dedicated flowing water loops, and conventional cameras with fewer sight lines and more limited fields of view than in the reference designs. It is shown that the spatial sampling provided by the reference designs is sufficient to satisfy target measurement requirements and that some reduction in field of view may be permissible. The accuracy of measurements with 16 N-based compact cameras is not yet established, and they fail to satisfy requirements for parameter range and time resolution by large margins

  15. Thinking through the Photographic Encounter: Engaging with the Camera as Nomadic Weapon

    Science.gov (United States)

    Coats, Cala

    2014-01-01

    This paper considers the photographic act as an affective and affirmative encounter--a reflexive, embodied, and relational community engagement that may produce a rupture in our habitual modes of thinking. The author uses the Deleuzo-Guattarian concept of the nomadic weapon to consider how the camera may become an affective trigger for…

  16. Acceptance/operational test procedure 241-AN-107 Video Camera System

    International Nuclear Information System (INIS)

    Pedersen, L.T.

    1994-01-01

    This procedure will document the satisfactory operation of the 241-AN-107 Video Camera System. The camera assembly, including camera mast, pan-and-tilt unit, camera, and lights, will be installed in Tank 241-AN-107 to monitor activities during the Caustic Addition Project. The camera focus, zoom, and iris remote controls will be functionally tested. The resolution and color rendition of the camera will be verified using standard reference charts. The pan-and-tilt unit will be tested for required ranges of motion, and the camera lights will be functionally tested. The master control station equipment, including the monitor, VCRs, printer, character generator, and video micrometer will be set up and performance tested in accordance with original equipment manufacturer's specifications. The accuracy of the video micrometer to measure objects in the range of 0.25 inches to 67 inches will be verified. The gas drying distribution system will be tested to ensure that a drying gas can be flowed over the camera and lens in the event that condensation forms on these components. This test will be performed by attaching the gas input connector, located in the upper junction box, to a pressurized gas supply and verifying that the check valve, located in the camera housing, opens to exhaust the compressed gas. The 241-AN-107 camera system will also be tested to assure acceptable resolution of the camera imaging components utilizing the camera system lights

  17. Deployable Wireless Camera Penetrators

    Science.gov (United States)

    Badescu, Mircea; Jones, Jack; Sherrit, Stewart; Wu, Jiunn Jeng

    2008-01-01

    A lightweight, low-power camera dart has been designed and tested for context imaging of sampling sites and ground surveys from an aerobot or an orbiting spacecraft in a microgravity environment. The camera penetrators also can be used to image any line-of-sight surface, such as cliff walls, that is difficult to access. Tethered cameras to inspect the surfaces of planetary bodies use both power and signal transmission lines to operate. A tether adds the possibility of inadvertently anchoring the aerobot, and requires some form of station-keeping capability of the aerobot if extended examination time is required. The new camera penetrators are deployed without a tether, weigh less than 30 grams, and are disposable. They are designed to drop from any altitude with the boost in transmitting power currently demonstrated at approximately 100-m line-of-sight. The penetrators also can be deployed to monitor lander or rover operations from a distance, and can be used for surface surveys or for context information gathering from a touch-and-go sampling site. Thanks to wireless operation, the complexity of the sampling or survey mechanisms may be reduced. The penetrators may be battery powered for short-duration missions, or have solar panels for longer or intermittent duration missions. The imaging device is embedded in the penetrator, which is dropped or projected at the surface of a study site at 90 to the surface. Mirrors can be used in the design to image the ground or the horizon. Some of the camera features were tested using commercial "nanny" or "spy" camera components with the charge-coupled device (CCD) looking at a direction parallel to the ground. Figure 1 shows components of one camera that weighs less than 8 g and occupies a volume of 11 cm3. This camera could transmit a standard television signal, including sound, up to 100 m. Figure 2 shows the CAD models of a version of the penetrator. A low-volume array of such penetrator cameras could be deployed from an

  18. [Correct contact lens hygiene].

    Science.gov (United States)

    Blümle, S; Kaercher, T; Khaireddin, R

    2013-06-01

    Although contact lenses have long been established in ophthalmology, practical aspects of handling contact lenses is becoming increasingly less important in the clinical training as specialist for ophthalmology. Simultaneously, for many reasons injuries due to wearing contact lenses are increasing. In order to correct this discrepancy, information on contact lenses and practical experience with them must be substantially increased from a medical perspective. This review article deals with the most important aspects for prevention of complications, i.e. contact lens hygiene.

  19. Touch And Go Camera System (TAGCAMS) for the OSIRIS-REx Asteroid Sample Return Mission

    Science.gov (United States)

    Bos, B. J.; Ravine, M. A.; Caplinger, M.; Schaffner, J. A.; Ladewig, J. V.; Olds, R. D.; Norman, C. D.; Huish, D.; Hughes, M.; Anderson, S. K.; Lorenz, D. A.; May, A.; Jackman, C. D.; Nelson, D.; Moreau, M.; Kubitschek, D.; Getzandanner, K.; Gordon, K. E.; Eberhardt, A.; Lauretta, D. S.

    2018-02-01

    NASA's OSIRIS-REx asteroid sample return mission spacecraft includes the Touch And Go Camera System (TAGCAMS) three camera-head instrument. The purpose of TAGCAMS is to provide imagery during the mission to facilitate navigation to the target asteroid, confirm acquisition of the asteroid sample, and document asteroid sample stowage. The cameras were designed and constructed by Malin Space Science Systems (MSSS) based on requirements developed by Lockheed Martin and NASA. All three of the cameras are mounted to the spacecraft nadir deck and provide images in the visible part of the spectrum, 400-700 nm. Two of the TAGCAMS cameras, NavCam 1 and NavCam 2, serve as fully redundant navigation cameras to support optical navigation and natural feature tracking. Their boresights are aligned in the nadir direction with small angular offsets for operational convenience. The third TAGCAMS camera, StowCam, provides imagery to assist with and confirm proper stowage of the asteroid sample. Its boresight is pointed at the OSIRIS-REx sample return capsule located on the spacecraft deck. All three cameras have at their heart a 2592 × 1944 pixel complementary metal oxide semiconductor (CMOS) detector array that provides up to 12-bit pixel depth. All cameras also share the same lens design and a camera field of view of roughly 44° × 32° with a pixel scale of 0.28 mrad/pixel. The StowCam lens is focused to image features on the spacecraft deck, while both NavCam lens focus positions are optimized for imaging at infinity. A brief description of the TAGCAMS instrument and how it is used to support critical OSIRIS-REx operations is provided.

  20. A Smart Assistant for Shooting Virtual Cinematography with Motion-Tracked Cameras

    OpenAIRE

    Lino , Christophe; Christie , Marc; Ranon , Roberto; Bares , William

    2011-01-01

    International audience; This demonstration shows how an automated assistant encoded with knowledge of cinematography practice can off er suggested viewpoints to a fi lmmaker operating a hand-held motion-tracked virtual camera device. Our system, called Director's Lens, uses an intelligent cinematography engine to compute, at the request of the lmmaker, a set of suitable camera placements for starting a shot that represent semantically and cinematically distinct choices for visualizing the cur...

  1. Christa McAuliffe and Barbara Morgan train with Airiflex camera

    Science.gov (United States)

    1985-01-01

    Two women in training at JSC as part of the Teacher-in-Space Project and a position on NASA's STS 51-L mission learn handling of the Airiflex motion picture camera used on Shuttle flights. Sharon Christa McAuliffe (left) was named as prime crewmember for the 51-L flight; and Barbara R. Morgan, here lending help with camera's lens, will serve as backup.

  2. Prolonging contact lens wear and making contact lens wear safer.

    Science.gov (United States)

    Foulks, Gary N

    2006-02-01

    To summarize the present status of safety and efficacy of contact lens wear. Literature review. Ovid Medline searches were performed on records from 1966 through 2005 using keywords: keratitis, contact lens complications, extended-wear contact lenses, and silicone-hydrogel contact lenses. Patients desire comfort, clarity of vision, and prolonged contact lens wear when contact lenses are used to correct refractive error. Practitioners desire patient satisfaction but also require maintenance of the integrity of the eye and no complications that jeopardize vision or health of the eye. Improvements in the oxygen permeability of the contact lens materials, design of the contact lens and its surface, and solutions for the maintenance of the lens have reduced but not eliminated the risks of infection, inflammation, and conjunctival papillary reaction associated with contact lens wear. The lessons of past and recent history suggest that patient education and practitioner participation in the management of contact lens wear continue to be critical factors for patient satisfaction and safety in the extended wear of contact lenses. The availability of highly oxygen permeable contact lenses has increased the tolerance and safety of extended contact lens wear, but patient instruction and education in proper use and care of lenses is required and caution is advised.

  3. The Dark Energy Camera

    Science.gov (United States)

    Flaugher, B.; Diehl, H. T.; Honscheid, K.; Abbott, T. M. C.; Alvarez, O.; Angstadt, R.; Annis, J. T.; Antonik, M.; Ballester, O.; Beaufore, L.; Bernstein, G. M.; Bernstein, R. A.; Bigelow, B.; Bonati, M.; Boprie, D.; Brooks, D.; Buckley-Geer, E. J.; Campa, J.; Cardiel-Sas, L.; Castander, F. J.; Castilla, J.; Cease, H.; Cela-Ruiz, J. M.; Chappa, S.; Chi, E.; Cooper, C.; da Costa, L. N.; Dede, E.; Derylo, G.; DePoy, D. L.; de Vicente, J.; Doel, P.; Drlica-Wagner, A.; Eiting, J.; Elliott, A. E.; Emes, J.; Estrada, J.; Fausti Neto, A.; Finley, D. A.; Flores, R.; Frieman, J.; Gerdes, D.; Gladders, M. D.; Gregory, B.; Gutierrez, G. R.; Hao, J.; Holland, S. E.; Holm, S.; Huffman, D.; Jackson, C.; James, D. J.; Jonas, M.; Karcher, A.; Karliner, I.; Kent, S.; Kessler, R.; Kozlovsky, M.; Kron, R. G.; Kubik, D.; Kuehn, K.; Kuhlmann, S.; Kuk, K.; Lahav, O.; Lathrop, A.; Lee, J.; Levi, M. E.; Lewis, P.; Li, T. S.; Mandrichenko, I.; Marshall, J. L.; Martinez, G.; Merritt, K. W.; Miquel, R.; Muñoz, F.; Neilsen, E. H.; Nichol, R. C.; Nord, B.; Ogando, R.; Olsen, J.; Palaio, N.; Patton, K.; Peoples, J.; Plazas, A. A.; Rauch, J.; Reil, K.; Rheault, J.-P.; Roe, N. A.; Rogers, H.; Roodman, A.; Sanchez, E.; Scarpine, V.; Schindler, R. H.; Schmidt, R.; Schmitt, R.; Schubnell, M.; Schultz, K.; Schurter, P.; Scott, L.; Serrano, S.; Shaw, T. M.; Smith, R. C.; Soares-Santos, M.; Stefanik, A.; Stuermer, W.; Suchyta, E.; Sypniewski, A.; Tarle, G.; Thaler, J.; Tighe, R.; Tran, C.; Tucker, D.; Walker, A. R.; Wang, G.; Watson, M.; Weaverdyck, C.; Wester, W.; Woods, R.; Yanny, B.; DES Collaboration

    2015-11-01

    The Dark Energy Camera is a new imager with a 2.°2 diameter field of view mounted at the prime focus of the Victor M. Blanco 4 m telescope on Cerro Tololo near La Serena, Chile. The camera was designed and constructed by the Dark Energy Survey Collaboration and meets or exceeds the stringent requirements designed for the wide-field and supernova surveys for which the collaboration uses it. The camera consists of a five-element optical corrector, seven filters, a shutter with a 60 cm aperture, and a charge-coupled device (CCD) focal plane of 250 μm thick fully depleted CCDs cooled inside a vacuum Dewar. The 570 megapixel focal plane comprises 62 2k × 4k CCDs for imaging and 12 2k × 2k CCDs for guiding and focus. The CCDs have 15 μm × 15 μm pixels with a plate scale of 0.″263 pixel-1. A hexapod system provides state-of-the-art focus and alignment capability. The camera is read out in 20 s with 6-9 electron readout noise. This paper provides a technical description of the camera's engineering, construction, installation, and current status.

  4. THE DARK ENERGY CAMERA

    Energy Technology Data Exchange (ETDEWEB)

    Flaugher, B.; Diehl, H. T.; Alvarez, O.; Angstadt, R.; Annis, J. T.; Buckley-Geer, E. J. [Fermi National Accelerator Laboratory, P.O. Box 500, Batavia, IL 60510 (United States); Honscheid, K. [Center for Cosmology and Astro-Particle Physics, The Ohio State University, Columbus, OH 43210 (United States); Abbott, T. M. C.; Bonati, M. [Cerro Tololo Inter-American Observatory, National Optical Astronomy Observatory, Casilla 603, La Serena (Chile); Antonik, M.; Brooks, D. [Department of Physics and Astronomy, University College London, Gower Street, London, WC1E 6BT (United Kingdom); Ballester, O.; Cardiel-Sas, L. [Institut de Física d’Altes Energies, Universitat Autònoma de Barcelona, E-08193 Bellaterra, Barcelona (Spain); Beaufore, L. [Department of Physics, The Ohio State University, Columbus, OH 43210 (United States); Bernstein, G. M. [Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, PA 19104 (United States); Bernstein, R. A. [Carnegie Observatories, 813 Santa Barbara St., Pasadena, CA 91101 (United States); Bigelow, B.; Boprie, D. [Department of Physics, University of Michigan, Ann Arbor, MI 48109 (United States); Campa, J. [Centro de Investigaciones Energèticas, Medioambientales y Tecnológicas (CIEMAT), Madrid (Spain); Castander, F. J., E-mail: diehl@fnal.gov [Institut de Ciències de l’Espai, IEEC-CSIC, Campus UAB, Facultat de Ciències, Torre C5 par-2, E-08193 Bellaterra, Barcelona (Spain); Collaboration: DES Collaboration; and others

    2015-11-15

    The Dark Energy Camera is a new imager with a 2.°2 diameter field of view mounted at the prime focus of the Victor M. Blanco 4 m telescope on Cerro Tololo near La Serena, Chile. The camera was designed and constructed by the Dark Energy Survey Collaboration and meets or exceeds the stringent requirements designed for the wide-field and supernova surveys for which the collaboration uses it. The camera consists of a five-element optical corrector, seven filters, a shutter with a 60 cm aperture, and a charge-coupled device (CCD) focal plane of 250 μm thick fully depleted CCDs cooled inside a vacuum Dewar. The 570 megapixel focal plane comprises 62 2k × 4k CCDs for imaging and 12 2k × 2k CCDs for guiding and focus. The CCDs have 15 μm × 15 μm pixels with a plate scale of 0.″263 pixel{sup −1}. A hexapod system provides state-of-the-art focus and alignment capability. The camera is read out in 20 s with 6–9 electron readout noise. This paper provides a technical description of the camera's engineering, construction, installation, and current status.

  5. Reflexive Aero Structures for Enhanced Survivability Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Cornerstone Research Group Inc. (CRG) will develop an advanced reflexive structure technology system to increase the survivability of future systems constructed of...

  6. Structural cure for reflex syncope?

    Science.gov (United States)

    Sulke, Neil; Eysenck, William; Badiani, Sveeta; Furniss, Stephen

    2016-01-20

    The ROX Coupler is a device that allows creation of a central arteriovenous anastomosis at the iliac level. The device has been shown to improve exercise capacity in patients with chronic obstructive pulmonary disease and is CE marked for the treatment of resistant and uncontrolled hypertension. Reflex syncope is a challenging clinical condition with limited proven therapeutic options. We describe the resolution of symptoms and tilt table response of a patient who underwent insertion of a ROX Coupler to treat hypertension, and also incidentally had pre-existing vasodepressor syncope. 2016 BMJ Publishing Group Ltd.

  7. Dysautonomia, fibromyalgia and reflex dystrophy

    Science.gov (United States)

    Eisinger, Jean

    2007-01-01

    Autonomic nervous system dysfunction observed in fibromyalgia, characterized without exception by a sympathetic hyperactivity and hyporeactivity, has been reported. However, several studies demonstrated reduced levels of norepinephrine and neuropeptide Y at rest and after tilt table in some patients, which was improved by beta-stimulating agents. These findings support heterogeneity in fibromyalgia-associated dysautonomia. Fibromyalgia could be a generalized sympathetic dystrophy since both conditions are activated by trauma and partly linked to sympathetic mechanisms. Yet they differ on several points: hormonal and neurochemical abnormalities are observed in fibromyalgia whereas activation by peripheral trauma and hyperosteolysis are observed in reflex sympathetic dystrophy. PMID:17626612

  8. Object recognition through turbulence with a modified plenoptic camera

    Science.gov (United States)

    Wu, Chensheng; Ko, Jonathan; Davis, Christopher

    2015-03-01

    Atmospheric turbulence adds accumulated distortion to images obtained by cameras and surveillance systems. When the turbulence grows stronger or when the object is further away from the observer, increasing the recording device resolution helps little to improve the quality of the image. Many sophisticated methods to correct the distorted images have been invented, such as using a known feature on or near the target object to perform a deconvolution process, or use of adaptive optics. However, most of the methods depend heavily on the object's location, and optical ray propagation through the turbulence is not directly considered. Alternatively, selecting a lucky image over many frames provides a feasible solution, but at the cost of time. In our work, we propose an innovative approach to improving image quality through turbulence by making use of a modified plenoptic camera. This type of camera adds a micro-lens array to a traditional high-resolution camera to form a semi-camera array that records duplicate copies of the object as well as "superimposed" turbulence at slightly different angles. By performing several steps of image reconstruction, turbulence effects will be suppressed to reveal more details of the object independently (without finding references near the object). Meanwhile, the redundant information obtained by the plenoptic camera raises the possibility of performing lucky image algorithmic analysis with fewer frames, which is more efficient. In our work, the details of our modified plenoptic cameras and image processing algorithms will be introduced. The proposed method can be applied to coherently illuminated object as well as incoherently illuminated objects. Our result shows that the turbulence effect can be effectively suppressed by the plenoptic camera in the hardware layer and a reconstructed "lucky image" can help the viewer identify the object even when a "lucky image" by ordinary cameras is not achievable.

  9. Modular scintillation camera

    International Nuclear Information System (INIS)

    Barrett, H. H.

    1985-01-01

    Improved optical coupling modules to be used in coded-aperture-type radiographic imaging systems. In a first system, a rotating slit coded-aperture is employed between the radioactive object and the module. The module consists of one pair of side-by-side photomultipliers receiving light rays from a scintillation crystal exposed to the object via the coded-aperture. The light rays are guided to the photomultipliers by a mask having a central transverse transparent window, or by a cylindrical lens, the mask or lens being mounted in a light-conveying quartz block assembly providing internal reflections at opposite faces of the assembly. This generates output signals from the photomultipliers which can be utilized to compute one-dimensional coordinate values for restoring the image of the radioactive object on a display screen. In another form of optical coupling module, usable with other types of coded-apertures, four square photomultipliers form a substantially square block and receive light rays from scintillations from a scintillation crystal exposed to the radioactive object via the coded-aperture. The light rays are guided to the photomultipliers by a square mask or a centrally transparent square lens configuration mounted in a light-conveying assembly formed by internally reflecting quartz blocks, the optical rays being directed to the respective photomultipliers so as to generate resultant output signals which can be utilized to compute image coordinate values for two-dimensional representation of the radioactive object being examined

  10. A method for measuring modulation transfer function of CCD device in remote camera with grating pattern

    Science.gov (United States)

    Chen, Yuheng; Chen, Xinhua; Shen, Weimin

    2008-03-01

    The remote camera that is developed by us is the exclusive functional load of a micro-satellite. Modulation transfer function (MTF) is a direct and accurate parameter to evaluate the system performance of a remote camera, and the MTF of a camera is jointly decided by the MTF of camera lens and its CCD device. The MTF of the camera lens can be tested directly with commercial optical system testing instrument, but it is indispensable to measure the MTF of the CCD device accurately before setting up the whole camera to evaluate the performance of the whole camera in advance. Compared with other existed MTF measuring methods, this method using grating pattern requires less equipment and simpler arithmetic. Only one complete scan of the grating pattern and later data processing and interpolation are needed to get the continuous MTF curves of the whole camera and its CCD device. High-precision optical system testing instrument guarantees the precision of this indirect measuring method. This indirect method to measure MTF is of reference use for the method of testing MTF of electronic device and for gaining MTF indirectly from corresponding CTF.

  11. Ultra-miniature catadioptrical system for an omnidirectional camera

    Science.gov (United States)

    Gimkiewicz, C.; Urban, C.; Innerhofer, E.; Ferrat, P.; Neukom, S.; Vanstraelen, G.; Seitz, P.

    2008-04-01

    The restricted field of view of traditional camera technology is increasingly limiting in many relevant applications such as security, surveillance, automotive, robotics, autonomous navigation or domotics. Omnidirectional cameras with their horizontal field of view of 360° would be ideal devices for these applications if they were small, cost-effective, robust and lightweight. Conventional catadioptric system designs require mirror diameters and optical path lengths of several centimeters, often leading to solutions that are too large and too heavy to be practical. We are presenting a novel optical design for an ultra-miniature camera that is so small and lightweight that it can be used as a key navigation aid for an autonomous flying micro-robot. The catadioptrical system consists of two components with a field-stop in-between: the first subsystem consists of a reflecting mirror and two refracting lens surfaces, and the second subsystem contains the imaging lens with two refractive surfaces. The field of view is 10°(upward) and 35°(downward). A field stop diameter of 1 mm and a back focal length of 2.3 mm have been achieved. For low-cost mass fabrication, the lens designs are optimised for production by injection moulding. Measurements of the first omnidirectional lens prototypes with a high-resolution imager show a performance close to the simulated values concerning spot size and image formation. The total weight of the optics is only 2 g including all mechanical mounts. The system's outer dimensions are 14.4 mm in height, with a 11.4 mm × 11.4 mm foot print, including the image sensor and its casing.

  12. SCC500: next-generation infrared imaging camera core products with highly flexible architecture for unique camera designs

    Science.gov (United States)

    Rumbaugh, Roy N.; Grealish, Kevin; Kacir, Tom; Arsenault, Barry; Murphy, Robert H.; Miller, Scott

    2003-09-01

    A new 4th generation MicroIR architecture is introduced as the latest in the highly successful Standard Camera Core (SCC) series by BAE SYSTEMS to offer an infrared imaging engine with greatly reduced size, weight, power, and cost. The advanced SCC500 architecture provides great flexibility in configuration to include multiple resolutions, an industry standard Real Time Operating System (RTOS) for customer specific software application plug-ins, and a highly modular construction for unique physical and interface options. These microbolometer based camera cores offer outstanding and reliable performance over an extended operating temperature range to meet the demanding requirements of real-world environments. A highly integrated lens and shutter is included in the new SCC500 product enabling easy, drop-in camera designs for quick time-to-market product introductions.

  13. A Simple Model of the Accommodating Lens of the Human Eye

    Science.gov (United States)

    Oommen, Vinay; Kanthakumar, Praghalathan

    2014-01-01

    The human eye is often discussed as optically equivalent to a photographic camera. The iris is compared with the shutter, the pupil to the aperture, and the retina to the film, and both have lens systems to focus rays of light. Although many similarities exist, a major difference between the two systems is the mechanism involved in focusing an…

  14. Communities, Cameras, and Conservation

    Science.gov (United States)

    Patterson, Barbara

    2012-01-01

    Communities, Cameras, and Conservation (CCC) is the most exciting and valuable program the author has seen in her 30 years of teaching field science courses. In this citizen science project, students and community volunteers collect data on mountain lions ("Puma concolor") at four natural areas and public parks along the Front Range of Colorado.…

  15. Mars Observer camera

    Science.gov (United States)

    Malin, M. C.; Danielson, G. E.; Ingersoll, A. P.; Masursky, H.; Veverka, J.; Ravine, M. A.; Soulanille, T. A.

    1992-01-01

    The Mars Observer camera (MOC) is a three-component system (one narrow-angle and two wide-angle cameras) designed to take high spatial resolution pictures of the surface of Mars and to obtain lower spatial resolution, synoptic coverage of the planet's surface and atmosphere. The cameras are based on the 'push broom' technique; that is, they do not take 'frames' but rather build pictures, one line at a time, as the spacecraft moves around the planet in its orbit. MOC is primarily a telescope for taking extremely high resolution pictures of selected locations on Mars. Using the narrow-angle camera, areas ranging from 2.8 km x 2.8 km to 2.8 km x 25.2 km (depending on available internal digital buffer memory) can be photographed at about 1.4 m/pixel. Additionally, lower-resolution pictures (to a lowest resolution of about 11 m/pixel) can be acquired by pixel averaging; these images can be much longer, ranging up to 2.8 x 500 km at 11 m/pixel. High-resolution data will be used to study sediments and sedimentary processes, polar processes and deposits, volcanism, and other geologic/geomorphic processes.

  16. The world's fastest camera

    CERN Multimedia

    Piquepaille, Roland

    2006-01-01

    This image processor is not your typical digital camera. It took 6 years to 20 people and $6 million to build the "Regional Calorimeter Trigger"(RCT) which will be a component of the Compact Muon Solenoid (CMS) experiment, one of the detectors on the Large Hadron Collider (LHC) in Geneva, Switzerland (1 page)

  17. Camera as Cultural Critique

    DEFF Research Database (Denmark)

    Suhr, Christian

    2015-01-01

    researchers, cameras, and filmed subjects already inherently comprise analytical decisions. It is these ethnographic qualities inherent in audiovisual and photographic imagery that make it of particular value to a participatory anthropological enterprise that seeks to resist analytic closure and seeks instead...

  18. Automatic Camera Control

    DEFF Research Database (Denmark)

    Burelli, Paolo; Preuss, Mike

    2014-01-01

    Automatically generating computer animations is a challenging and complex problem with applications in games and film production. In this paper, we investigate howto translate a shot list for a virtual scene into a series of virtual camera configurations — i.e automatically controlling the virtual...

  19. DotLens smartphone microscopy for biological and biomedical applications (Conference Presentation)

    Science.gov (United States)

    Sung, Yu-Lung; Zhao, Fusheng; Shih, Wei-Chuan

    2017-02-01

    Recent advances in inkjet-printed optics have created a new class of lens fabrication technique. Lenses with a tunable geometry, magnification, and focal length can be fabricated by dispensing controlled amounts of liquid polymer onto a heated surface. This fabrication technique is highly cost-effective, and can achieve optically smooth surface finish. Dubbed DotLens, a single of which weighs less than 50 mg and occupies a volume less than 50 μL. DotLens can be attached onto any smartphone camera akin to a contact lens, and enable smartphones to obtain image resolution as fine as 1 µm. The surface curvature modifies the optical path of light to the image sensor, and enables the camera to focus as close as 2 mm. This enables microscopic imaging on a smartphone without any additional attachments, and has shown great potential in mobile point-of-care diagnostic systems, particularly for histology of tissue sections and cytology of blood cells. DotLens Smartphone Microscopy represents an innovative approach fundamentally different from other smartphone microscopes. In this paper, we describe the application and performance of DotLens smartphone microscopy in biological and biomedical research. In particular, we show recent results from images collected from pathology tissue slides with cancer features. In addition, we show performance in cytological analysis of blood smear. This tool has empowered Citizen Science investigators to collect microscopic images from various interesting objects.

  20. Zoom lens calibration with zoom- and focus-related intrinsic parameters applied to bundle adjustment

    Science.gov (United States)

    Zheng, Shunyi; Wang, Zheng; Huang, Rongyong

    2015-04-01

    A zoom lens is more flexible for photogrammetric measurements under diverse environments than a fixed lens. However, challenges in calibration of zoom-lens cameras preclude the wide use of zoom lenses in the field of close-range photogrammetry. Thus, a novel zoom lens calibration method is proposed in this study. In this method, instead of conducting modeling after monofocal calibrations, we summarize the empirical zoom/focus models of intrinsic parameters first and then incorporate these parameters into traditional collinearity equations to construct the fundamental mathematical model, i.e., collinearity equations with zoom- and focus-related intrinsic parameters. Similar to monofocal calibration, images taken at several combinations of zoom and focus settings are processed in a single self-calibration bundle adjustment. In the self-calibration bundle adjustment, three types of unknowns, namely, exterior orientation parameters, unknown space point coordinates, and model coefficients of the intrinsic parameters, are solved simultaneously. Experiments on three different digital cameras with zoom lenses support the feasibility of the proposed method, and their relative accuracies range from 1:4000 to 1:15,100. Furthermore, the nominal focal length written in the exchangeable image file header is found to lack reliability in experiments. Thereafter, the joint influence of zoom lens instability and zoom recording errors is further analyzed quantitatively. The analysis result is consistent with the experimental result and explains the reason why zoom lens calibration can never have the same accuracy as monofocal self-calibration.

  1. [Reflex sympathetic dystrophy of childhood: one case].

    Science.gov (United States)

    Jouary, T; Boralevi, F; Pillet, P; Taieb, A; Léauté-Labrèze, C

    2002-10-01

    Reflex sympathetic dystrophy (Complex Regional Pain Syndrome type 1) is little known by dermatologists. We report a pediatric case of reflex sympathetic dystrophy with predominant cutaneous involvement. A 10 year-old girl presented a warm, painful and relapsing right hand edema for seven months (three outbreaks). The hand was cyanotic, pigmented and painful. Routine blood tests were normal. Radiography and radionuclide bone scan were consistent with stage 1 reflex sympathetic dystrophy. Physiotherapy led to dramatic improvement. Reflex sympathetic dystrophy is known since the XVIIIth century. In the last decade, progress in radiology and bone scan have provided elements for understanding the physiopathology of the disease. Microvascular abnormalities under the control of sympathetic nervous system are characteristic of different stages of reflex sympathetic dystrophy. Recently, neurovascular system experiments showed that sympathetic reflex tonus changes may be controlled by the central nervous system. Dermatologic changes of reflex sympathetic dystrophy are well known: edema and erythema in first stage, cyanosis in second stage, sclerosis and atrophia in third stage, but pediatric cases are rarely reported. Reflex sympathetic dystrophy is a complex disease, however its physiopathology is now understood. The clinical presentation can be atypical and the dermatologist may be the first to be consulted.

  2. The PAU Camera

    Science.gov (United States)

    Casas, R.; Ballester, O.; Cardiel-Sas, L.; Carretero, J.; Castander, F. J.; Castilla, J.; Crocce, M.; de Vicente, J.; Delfino, M.; Fernández, E.; Fosalba, P.; García-Bellido, J.; Gaztañaga, E.; Grañena, F.; Jiménez, J.; Madrid, F.; Maiorino, M.; Martí, P.; Miquel, R.; Neissner, C.; Ponce, R.; Sánchez, E.; Serrano, S.; Sevilla, I.; Tonello, N.; Troyano, I.

    2011-11-01

    The PAU Camera (PAUCam) is a wide-field camera designed to be mounted at the William Herschel Telescope (WHT) prime focus, located at the Observatorio del Roque de los Muchachos in the island of La Palma (Canary Islands).Its primary function is to carry out a cosmological survey, the PAU Survey, covering an area of several hundred square degrees of sky. Its purpose is to determine positions and distances using photometric redshift techniques. To achieve accurate photo-z's, PAUCam will be equipped with 40 narrow-band filters covering the range from 450 to850 nm, and six broad-band filters, those of the SDSS system plus the Y band. To fully cover the focal plane delivered by the telescope optics, 18 CCDs 2k x 4k are needed. The pixels are square of 15 μ m size. The optical characteristics of the prime focus corrector deliver a field-of-view where eight of these CCDs will have an illumination of more than 95% covering a field of 40 arc minutes. The rest of the CCDs will occupy the vignetted region extending the field diameter to one degree. Two of the CCDs will be devoted to auto-guiding.This camera have some innovative features. Firstly, both the broad-band and the narrow-band filters will be placed in mobile trays, hosting 16 such filters at most. Those are located inside the cryostat at few millimeters in front of the CCDs when observing. Secondly, a pressurized liquid nitrogen tank outside the camera will feed a boiler inside the cryostat with a controlled massflow. The read-out electronics will use the Monsoon architecture, originally developed by NOAO, modified and manufactured by our team in the frame of the DECam project (the camera used in the DES Survey).PAUCam will also be available to the astronomical community of the WHT.

  3. I Am Not a Camera: On Visual Politics and Method. A Response to Roy Germano

    NARCIS (Netherlands)

    Yanow, D.

    2014-01-01

    No observational method is "point and shoot." Even bracketing interpretive methodologies and their attendant philosophies, a researcher-including an experimentalist-always frames observation in terms of the topic of interest. I cannot ever be "just a camera lens," not as researcher and not as

  4. Compliance among soft contact lens wearers.

    OpenAIRE

    Kuzman, Tomislav; Barišić Kutija, Marija; Masnec, Sanja; Jandroković, Sonja; Mrazovac, Danijela; Jurišić, Darija; Škegro, Ivan; Kalauz, Miro; Kordić, Rajko

    2014-01-01

    Contact lens compliance is proven to be crucial for preventing lens wear-related complications because of the interdependence of the steps in lens care regime and their influence on lens system microbial contamination. Awareness of the patients' lens handling compliance as well as correct recognition of non-compliant behaviours is the basis for creating more targeted strategies for patient education. The aim of this study was to investigate compliance among soft contact lens (SCL) wearers in ...

  5. Panoramic lens applications revisited

    Science.gov (United States)

    Thibault, Simon

    2008-04-01

    During the last few years, innovative optical design strategies to generate and control image mapping have been successful in producing high-resolution digital imagers and projectors. This new generation of panoramic lenses includes catadioptric panoramic lenses, panoramic annular lenses, visible/IR fisheye lenses, anamorphic wide-angle attachments, and visible/IR panomorph lenses. Given that a wide-angle lens images a large field of view on a limited number of pixels, a systematic pixel-to-angle mapping will help the efficient use of each pixel in the field of view. In this paper, we present several modern applications of these modern types of hemispheric lenses. Recently, surveillance and security applications have been proposed and published in Security and Defence symposium. However, modern hemispheric lens can be used in many other fields. A panoramic imaging sensor contributes most to the perception of the world. Panoramic lenses are now ready to be deployed in many optical solutions. Covered applications include, but are not limited to medical imaging (endoscope, rigiscope, fiberscope...), remote sensing (pipe inspection, crime scene investigation, archeology...), multimedia (hemispheric projector, panoramic image...). Modern panoramic technologies allow simple and efficient digital image processing and the use of standard image analysis features (motion estimation, segmentation, object tracking, pattern recognition) in the complete 360° hemispheric area.

  6. MISR radiometric camera-by-camera Cloud Mask V004

    Data.gov (United States)

    National Aeronautics and Space Administration — This file contains the Radiometric camera-by-camera Cloud Mask dataset. It is used to determine whether a scene is classified as clear or cloudy. A new parameter has...

  7. Reflexive Aero Structures for Enhanced Survivability, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Cornerstone Research Group Inc. (CRG) proposes to develop an advanced reflexive structure system to increase the survivability of aerostructures. This reflexive...

  8. Reflexive Learning through Visual Methods

    DEFF Research Database (Denmark)

    Frølunde, Lisbeth

    2014-01-01

    What. This chapter concerns how visual methods and visual materials can support visually oriented, collaborative, and creative learning processes in education. The focus is on facilitation (guiding, teaching) with visual methods in learning processes that are designerly or involve design. Visual...... or professional, to facilitate with visual methods in a critical, reflective, and experimental way. The chapter offers recommendations for facilitating with visual methods to support playful, emergent designerly processes. The chapter also has a critical, situated perspective. Where. This chapter offers case...... challenges are discussed, including supporting difficult group collaborative processes (such as dealing with interpersonal tensions). You will gain an understanding about how and why to work with visual methods and how to develop a dynamic, reflexive facilitation practice. The chapter contains...

  9. Reflexive criteria of sociological research

    Directory of Open Access Journals (Sweden)

    R T Ubaydullaeva

    2014-12-01

    Full Text Available The article is devoted to the sociological criteria of explaining the way of thinking and actions of subjects, their spiritual and moral positions and intellectual forces that form the laws of social life. The author seeks to adapt such categories as ‘meaning of life’, ‘human dignity’, ‘rationality’ etc. for the purposes of sociological analysis by methodological construction of some real life dichotomies such as ‘subjective meaning and social function’, ‘the real and the ideal’, ‘the demanded and the excluded’. Thus, the author studies economic, political and technical processes in terms of both positivity and negativity of social interaction and states that given the increasing differentiation of the society and the contradictory trends of social development the reflexive criteria that take into account the socio-cultural nature of the man help to find one’s own model of development.

  10. Consumer electronic optics: how small can a lens be: the case of panomorph lenses

    Science.gov (United States)

    Thibault, Simon; Parent, Jocelyn; Zhang, Hu; Du, Xiaojun; Roulet, Patrice

    2014-09-01

    In 2014, miniature camera modules are applied to a variety of applications such as webcam, mobile phone, automotive, endoscope, tablets, portable computers and many other products. Mobile phone cameras are probably one of the most challenging parts due to the need for smaller and smaller total track length (TTL) and optimized embedded image processing algorithms. As the technology is developing, higher resolution and higher image quality, new capabilities are required to fulfil the market needs. Consequently, the lens system becomes more complex and requires more optical elements and/or new optical elements. What is the limit? How small an injection molded lens can be? We will discuss those questions by comparing two wide angle lenses for consumer electronic market. The first lens is a 6.56 mm (TTL) panoramic (180° FOV) lens built in 2012. The second is a more recent (2014) panoramic lens (180° FOV) with a TTL of 3.80 mm for mobile phone camera. Both optics are panomorph lenses used with megapixel sensors. Between 2012 and 2014, the development in design and plastic injection molding allowed a reduction of the TTL by more than 40%. This TTL reduction has been achieved by pushing the lens design to the extreme (edge/central air and material thicknesses as well as lens shape). This was also possible due to a better control of the injection molding process and material (low birefringence, haze and thermal stability). These aspects will be presented and discussed. During the next few years, we don't know if new material will come or new process but we will still need innovative people and industries to push again the limits.

  11. CCD Camera Detection of HIV Infection.

    Science.gov (United States)

    Day, John R

    2017-01-01

    Rapid and precise quantification of the infectivity of HIV is important for molecular virologic studies, as well as for measuring the activities of antiviral drugs and neutralizing antibodies. An indicator cell line, a CCD camera, and image-analysis software are used to quantify HIV infectivity. The cells of the P4R5 line, which express the receptors for HIV infection as well as β-galactosidase under the control of the HIV-1 long terminal repeat, are infected with HIV and then incubated 2 days later with X-gal to stain the infected cells blue. Digital images of monolayers of the infected cells are captured using a high resolution CCD video camera and a macro video zoom lens. A software program is developed to process the images and to count the blue-stained foci of infection. The described method allows for the rapid quantification of the infected cells over a wide range of viral inocula with reproducibility, accuracy and at relatively low cost.

  12. Photometric Calibration and Image Stitching for a Large Field of View Multi-Camera System

    Directory of Open Access Journals (Sweden)

    Yu Lu

    2016-04-01

    Full Text Available A new compact large field of view (FOV multi-camera system is introduced. The camera is based on seven tiny complementary metal-oxide-semiconductor sensor modules covering over 160° × 160° FOV. Although image stitching has been studied extensively, sensor and lens differences have not been considered in previous multi-camera devices. In this study, we have calibrated the photometric characteristics of the multi-camera device. Lenses were not mounted on the sensor in the process of radiometric response calibration to eliminate the influence of the focusing effect of uniform light from an integrating sphere. Linearity range of the radiometric response, non-linearity response characteristics, sensitivity, and dark current of the camera response function are presented. The R, G, and B channels have different responses for the same illuminance. Vignetting artifact patterns have been tested. The actual luminance of the object is retrieved by sensor calibration results, and is used to blend images to make panoramas reflect the objective luminance more objectively. This compensates for the limitation of stitching images that are more realistic only through the smoothing method. The dynamic range limitation of can be resolved by using multiple cameras that cover a large field of view instead of a single image sensor with a wide-angle lens. The dynamic range is expanded by 48-fold in this system. We can obtain seven images in one shot with this multi-camera system, at 13 frames per second.

  13. Body worn camera

    Science.gov (United States)

    Aishwariya, A.; Pallavi Sudhir, Gulavani; Garg, Nemesa; Karthikeyan, B.

    2017-11-01

    A body worn camera is small video camera worn on the body, typically used by police officers to record arrests, evidence from crime scenes. It helps preventing and resolving complaints brought by members of the public; and strengthening police transparency, performance, and accountability. The main constants of this type of the system are video format, resolution, frames rate, and audio quality. This system records the video in .mp4 format with 1080p resolution and 30 frames per second. One more important aspect to while designing this system is amount of power the system requires as battery management becomes very critical. The main design challenges are Size of the Video, Audio for the video. Combining both audio and video and saving it in .mp4 format, Battery, size that is required for 8 hours of continuous recording, Security. For prototyping this system is implemented using Raspberry Pi model B.

  14. Positron emission tomography camera

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    A positron emission tomography camera having a plurality of detector rings positioned side-by-side or offset by one-half of the detector cross section around a patient area to detect radiation therefrom. Each ring contains a plurality of scintillation detectors which are positioned around an inner circumference with a septum ring extending inwardly from the inner circumference along each outer edge of each ring. An additional septum ring is positioned in the middle of each ring of detectors and parallel to the other septa rings, whereby the inward extent of all the septa rings may be reduced by one-half and the number of detectors required in each ring is reduced. The additional septa reduces the costs of the positron camera and improves its performance

  15. The NEAT Camera Project

    Science.gov (United States)

    Jr., Ray L. Newburn

    1995-01-01

    The NEAT (Near Earth Asteroid Tracking) camera system consists of a camera head with a 6.3 cm square 4096 x 4096 pixel CCD, fast electronics, and a Sun Sparc 20 data and control computer with dual CPUs, 256 Mbytes of memory, and 36 Gbytes of hard disk. The system was designed for optimum use with an Air Force GEODSS (Ground-based Electro-Optical Deep Space Surveillance) telescope. The GEODSS telescopes have 1 m f/2.15 objectives of the Ritchey-Chretian type, designed originally for satellite tracking. Installation of NEAT began July 25 at the Air Force Facility on Haleakala, a 3000 m peak on Maui in Hawaii.

  16. Gamma camera display system

    International Nuclear Information System (INIS)

    Stout, K.J.

    1976-01-01

    A gamma camera having an array of photomultipliers coupled via pulse shaping circuitry and a resistor weighting circuit to a display for forming an image of a radioactive subject is described. A linearizing circuit is coupled to the weighting circuit, the linearizing circuit including a nonlinear feedback circuit with diode coupling to the weighting circuit for linearizing the correspondence between points of the display and points of the subject. 4 Claims, 5 Drawing Figures

  17. Scanning gamma camera

    International Nuclear Information System (INIS)

    Engdahl, L.W.; Batter, J.F. Jr.; Stout, K.J.

    1977-01-01

    A scanning system for a gamma camera providing for the overlapping of adjacent scan paths is described. A collimator mask having tapered edges provides for a graduated reduction in intensity of radiation received by a detector thereof, the reduction in intensity being graduated in a direction normal to the scanning path to provide a blending of images of adjacent scan paths. 31 claims, 15 figures

  18. Crystalline lens radioprotectors

    International Nuclear Information System (INIS)

    Belkacemi, Y.; Pasquier, D.; Castelain, B.; Lartigau, E.; Warnet, J.M.

    2003-01-01

    During more than a half of century, numerous compounds have been tested in different models against radiation-induced cataract. In this report, we will review the radioprotectors that have been already tested for non-human crystalline lens protection. We will focus on the most important published studies in this topic and the mechanisms of cyto-protection reported in. vitro and in. vivo from animals. The most frequent mechanisms incriminated in the cyto-protective effect are: free radical scavenging, limitation of lipid peroxidation, modulation of cycle progression increase of intracellular reduced glutathione pool, reduction of DNA strand breaks and limitation of apoptotic cell death. Arnifostine (or Ethyol) and anethole dithiolethione (or Sulfarlem), already used clinically as chemo- and radio-protectants, could be further test?r for ocular radioprotection particularly for radiation-induced cataract. (author)

  19. Optical Design of the Camera for Transiting Exoplanet Survey Satellite (TESS)

    Science.gov (United States)

    Chrisp, Michael; Clark, Kristin; Primeau, Brian; Dalpiaz, Michael; Lennon, Joseph

    2015-01-01

    The optical design of the wide field of view refractive camera, 34 degrees diagonal field, for the TESS payload is described. This fast f/1.4 cryogenic camera, operating at -75 C, has no vignetting for maximum light gathering within the size and weight constraints. Four of these cameras capture full frames of star images for photometric searches of planet crossings. The optical design evolution, from the initial Petzval design, took advantage of Forbes aspheres to develop a hybrid design form. This maximized the correction from the two aspherics resulting in a reduction of average spot size by sixty percent in the final design. An external long wavelength pass filter was replaced by an internal filter coating on a lens to save weight, and has been fabricated to meet the specifications. The stray light requirements were met by an extended lens hood baffle design, giving the necessary off-axis attenuation.

  20. View from Above of Phoenix's Stowed Robotic Arm Camera

    Science.gov (United States)

    2008-01-01

    [figure removed for brevity, see original site] Click on image for animation This artist's animation of an imaginary camera zooming in from above shows the location of the Robotic Arm Camera on NASA's Phoenix Mars Lander as it acquires an image of the scoop at the end of the arm. Located just beneath the Robotic Arm Camera lens, the scoop is folded in the stowed position, with its open end facing the Robotic Arm Camera. The last frame in the animation shows the first image taken by the Robotic Arm Camera, one day after Phoenix landed on Mars. In the center of the image is the robotic scoop the lander will use to dig into the surface, collect samples and touch water ice on Mars for the first time. The scoop is in the stowed position, awaiting deployment of the robotic arm. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  1. To make a further explanation on some questions about optical imaging using a light field camera

    Science.gov (United States)

    Fu, Yun; Xu, Xiping; Yin, Peng

    2017-08-01

    In traditional optics, the focusing should be done before the exposuring. However, a light field camera makes it a reality to take a photograph before the focusing. The principle of a light field camera consists of some fundamental theories on optical imaging, including pinhole imaging, depth of focus, digital refocusing, synthetic aperture imaging, etc. It is easier for students to understand the above theories through learning the theory and experiment of a light field camera. Meanwhile it also involves some optical knowledge for a light field camera during the acquisition and processing images. In the paper, we will discuss the similarities and differences on optical properties among the pinhole, the convex lens and the light field camera. Our intention is to make these optical theories much easier to understand for students in our teaching work.

  2. Fabry-Perot interferometry using an image-intensified rotating-mirror streak camera

    International Nuclear Information System (INIS)

    Seitz, W.L.; Stacy, H.L.

    1983-01-01

    A Fabry-Perot velocity interferometer system is described that uses a modified rotating mirror streak camera to recrod the dynamic fringe positions. A Los Alamos Model 72B rotating-mirror streak camera, equipped with a beryllium mirror, was modified to include a high aperture (f/2.5) relay lens and a 40-mm image-intensifier tube such that the image normally formed at the film plane of the streak camera is projected onto the intensifier tube. Fringe records for thin (0.13 mm) flyers driven by a small bridgewire detonator obtained with a Model C1155-01 Hamamatsu and Model 790 Imacon electronic streak cameras are compared with those obtained with the image-intensified rotating-mirror streak camera (I 2 RMC). Resolution comparisons indicate that the I 2 RMC gives better time resolution than either the Hamamatsu or the Imacon for total writing times of a few microseconds or longer

  3. A near catastrophe from trigeminocardiac reflex

    Directory of Open Access Journals (Sweden)

    Parmod K Bithal

    2017-01-01

    Full Text Available Trigeminocardiac reflex is a brainstem reflex that results from stimulation of any branch of the trigeminal nerve along its course. It produces a constellation of signs and symptoms decrease in blood pressure (BP and heart rate, dysrhythmias, apnoea and increased gastric motility. We present a case of 80-year-old female patient who developed alarming hypotension and bradycardia during craniotomy for meningioma excision resulting from this reflex. In the face of refractory hypotension despite administering ephedrine and phenylephrine, we had to resort to adrenaline to restore her normal BP.

  4. Optomechanical integrated simulation of Mars medium resolution lens with large field of view

    Science.gov (United States)

    Yang, Wenqiang; Xu, Guangzhou; Yang, Jianfeng; Sun, Yi

    2017-10-01

    The lens of Mars detector is exposed to solar radiation and space temperature for long periods of time during orbit, so that the ambient temperature of the optical system is in a dynamic state. The optical and mechanical change caused by heat will lead to camera's visual axis drift and the wavefront distortion. The surface distortion of the optical lens includes the displacement of the rigid body and the distortion of the surface shape. This paper used the calculation method based on the integrated optomechanical analysis, to explore the impact of thermodynamic load on image quality. Through the analysis software, established a simulation model of the lens structure. The shape distribution and the surface characterization parameters of the lens in some temperature ranges were analyzed and compared. the PV / RMS value, deformation cloud of the lens surface and quality evaluation of imaging was achieved. This simulation has been successfully measured the lens surface shape and shape distribution under the load which is difficult to measure on the experimental conditions. The integrated simulation method of the optical machine can obtain the change of the optical parameters brought by the temperature load. It shows that the application of Integrated analysis has play an important role in guiding the designing the lens.

  5. Radiation-resistant camera tube

    International Nuclear Information System (INIS)

    Kuwahata, Takao; Manabe, Sohei; Makishima, Yasuhiro

    1982-01-01

    It was a long time ago that Toshiba launched on manufacturing black-and-white radiation-resistant camera tubes employing nonbrowning face-plate glass for ITV cameras used in nuclear power plants. Now in compliance with the increasing demand in nuclear power field, the Company is at grips with the development of radiation-resistant single color-camera tubes incorporating a color-stripe filter for color ITV cameras used under radiation environment. Herein represented are the results of experiments on characteristics of materials for single color-camera tubes and prospects for commercialization of the tubes. (author)

  6. Contact Lens Wear at Altitude: Subcontact Lens Bubble Formation

    Science.gov (United States)

    1987-11-01

    incidence of (PMMA) lenses . Reported here are the results of contact lens subcontact lens bubble formation under scleral lenses at bubble studies with soft...vision from formation of large bubbles greater than 6,096 m (20,000 It). With soft contact lenses , bubble under their contact lenses . They also found...always located at the limbus and were without sequela to vision or corneal epithelial integrity. scleral lenses used by Jaeckle were permeable to gases

  7. Straylight Measurements in Contact Lens Wear

    NARCIS (Netherlands)

    van der Meulen, Ivanka J. E.; Engelbrecht, Leonore A.; van Vliet, Johannes M. J.; Lapid-Gortzak, Ruth; Nieuwendaal, Carla P.; Mourits, Maarten P.; Schlingemann, Reinier O.; van den Berg, Thomas J. T. P.

    2010-01-01

    Purpose: (1) To quantify the effect of contact lens wear on straylight in rigid and soft contact lens wearers and (2) to relate findings to morphological changes and subjective complaints. Methods: Straylight was measured using the Oculus C-Quant during contact lens wear and after contact lens

  8. Approaching direct optimization of as-built lens performance

    Science.gov (United States)

    McGuire, James P.; Kuper, Thomas G.

    2012-10-01

    We describe a method approaching direct optimization of the rms wavefront error of a lens including tolerances. By including the effect of tolerances in the error function, the designer can choose to improve the as-built performance with a fixed set of tolerances and/or reduce the cost of production lenses with looser tolerances. The method relies on the speed of differential tolerance analysis and has recently become practical due to the combination of continuing increases in computer hardware speed and multiple core processing We illustrate the method's use on a Cooke triplet, a double Gauss, and two plastic mobile phone camera lenses.

  9. Situating reflexivities: voices, positionalities and representations in feminist ethnographic texts

    NARCIS (Netherlands)

    Nencel, L.S.

    2014-01-01

    This article traces the feminist discussion concerning the importance of reflexive analysis and reflexive writing for feminist research. It starts by describing two feminist currents that concern the way to be reflexive. The first, reflexivity as a corrective measure accords a great deal of

  10. Measurement of tendon reflexes by surface electromyography in normal subjects

    NARCIS (Netherlands)

    Stam, J.; van Crevel, H.

    1989-01-01

    A simple method for measuring the tendon reflexes was developed. A manually operated, electronic reflex hammer was applied that enabled measurement of the strength of tendon taps. Reflex responses were recorded by surface electromyography. Stimulus-response relations and latencies of tendon reflexes

  11. The PLATO camera

    Science.gov (United States)

    Laubier, D.; Bodin, P.; Pasquier, H.; Fredon, S.; Levacher, P.; Vola, P.; Buey, T.; Bernardi, P.

    2017-11-01

    PLATO (PLAnetary Transits and Oscillation of stars) is a candidate for the M3 Medium-size mission of the ESA Cosmic Vision programme (2015-2025 period). It is aimed at Earth-size and Earth-mass planet detection in the habitable zone of bright stars and their characterisation using the transit method and the asterosismology of their host star. That means observing more than 100 000 stars brighter than magnitude 11, and more than 1 000 000 brighter than magnitude 13, with a long continuous observing time for 20 % of them (2 to 3 years). This yields a need for an unusually long term signal stability. For the brighter stars, the noise requirement is less than 34 ppm.hr-1/2, from a frequency of 40 mHz down to 20 μHz, including all sources of noise like for instance the motion of the star images on the detectors and frequency beatings. Those extremely tight requirements result in a payload consisting of 32 synchronised, high aperture, wide field of view cameras thermally regulated down to -80°C, whose data are combined to increase the signal to noise performances. They are split into 4 different subsets pointing at 4 directions to widen the total field of view; stars in the centre of that field of view are observed by all 32 cameras. 2 extra cameras are used with color filters and provide pointing measurement to the spacecraft Attitude and Orbit Control System (AOCS) loop. The satellite is orbiting the Sun at the L2 Lagrange point. This paper presents the optical, electronic and electrical, thermal and mechanical designs devised to achieve those requirements, and the results from breadboards developed for the optics, the focal plane, the power supply and video electronics.

  12. Portraying Reflexivity in Health Services Research.

    Science.gov (United States)

    Rae, John; Green, Bill

    2016-09-01

    A model is proposed for supporting reflexivity in qualitative health research, informed by arguments from Bourdieu and Finlay. Bourdieu refers to mastering the subjective relation to the object at three levels-the overall social space, the field of specialists, and the scholastic universe. The model overlays Bourdieu's levels of objectivation with Finlay's three stages of research (pre-research, data collection, and data analysis). The intersections of these two ways of considering reflexivity, displayed as cells of a matrix, pose questions and offer prompts to productively challenge health researchers' reflexivity. Portraiture is used to show how these challenges and prompts can facilitate such reflexivity, as illustrated in a research project. © The Author(s) 2016.

  13. Reflexivity and the capacity to think.

    Science.gov (United States)

    Doyle, Sarah

    2013-02-01

    Reflexivity is fundamental to qualitative health research, yet notoriously difficult to unpack. Drawing on Wilfred Bion's work on the development of the capacity to think and to learn, I show how the capacity to think is an impermanent and fallible capacity, with the potential to materialize or evaporate at any number of different points. I use this conceptualization together with examples from published interview data to illustrate the difficulties for researchers attempting to sustain a reflexive approach, and to direct attention toward the possibilities for recovering and supporting the capacity to think. I counter some of the criticisms suggesting that reflexivity can be self-indulgent, and suggest instead that self-indulgence constitutes a failure of reflexivity. In the concluding discussions I acknowledge tensions accompanying the use of psychoanalytic theories for research purposes, and point to emerging psychosocial approaches as one way of negotiating these.

  14. Entrepreneurship Teaching Conducted as Strategic Reflexive Conversation

    DEFF Research Database (Denmark)

    Kristiansson, Michael

    The paper intends exploring and ascertaining whether the concept of strategic reflexive conversation can profitably be applied to entrepreneurship. As a start, a process of conceptualisation is undertaken, which is instrumental in placing the notion of strategic reflexive conversation...... into a knowledge management perspective. Strategic reflexive conversation is presented in an enhanced and updated version, which is contrasted to entrepreneurship through reflection. The findings indicate and it can be concluded that, with some important reservations, strategic reflexive conversation can...... advantageously, and on a pilot basis, be applied to entrepreneurship in practical environments and within the framework of entrepreneurship-centred teaching. The present theoretical investigation is solely of an introductory nature and steps are considered that can lead to the planning of additional exploratory...

  15. [ Sudeck's bone atrophy (reflex sympathetic dystrophy)].

    Science.gov (United States)

    Hayashi, Yasufumi

    2008-07-01

    Reflex sympathetic dystrophy is a disease clinically characterized severe pain, allodynia (severe pain caused by a touch) and over-reaction of pain sensation after a minor injury. In 1994, reflex sympathetic dystrophy was given a name of complex regional pain syndrome type 1 by a international congress, because local blockade of the sympathetic nerve has not been found to be invariably effective. Treatment system for reflex sympathetic dystrophy is composed of medicament therapy including oral administration and/or injection of drug, physical therapy such as thermotherapy and gently passive movement, surgical treatment and psychotherapy. Treatment with injection of pamidronate for 23 patients with reflex sympathetic dystrophy revealed to reduced the grade of pain to two third compared to pre-treatment period, and local intravenous block with local anesthetic drug and steroid hormone disappeared the almost symptoms in cases of early phase.

  16. Morbidity in reflex sympathetic dystrophy

    Science.gov (United States)

    Murray, C.; Cohen, A.; Perkins, T.; Davidson, J.; Sills, J.

    2000-01-01

    Reflex sympathetic dystrophy (RSD), an unusual diagnosis in general paediatrics, is well recognised by paediatric rheumatologists. This study reports the presentation and the clinical course of 46 patients (35 female, age range 8-15.2) with RSD. The patients saw professionals from an average of 2.3 specialties (range 1-5). Twenty five (54%) had a history of trauma. Median time to diagnosis was 12 weeks (range 1-130). Many children had multiple investigations and treatments. Once diagnosis was made, treatment followed with physiotherapy and analgesics. Median time to recovery was seven weeks (range 1-140), with 27.5% relapsing. Nine children required assessment by the child and adolescent psychiatry team. This disease, though rare, has significant morbidity and it is therefore important to raise clinicians' awareness of RSD in childhood. Children with the condition may then be recognised and referred for appropriate management earlier, and spared unnecessary investigations and treatments which may exacerbate the condition.

 PMID:10685927

  17. Somatosensory and acoustic brain stem reflex myoclonus.

    OpenAIRE

    Shibasaki, H; Kakigi, R; Oda, K; Masukawa, S

    1988-01-01

    A patient with brain stem reflex myoclonus due to a massive midbrain infarct was studied electrophysiologically. Myoclonic jerks were elicited at variable latencies by tapping anywhere on the body or by acoustic stimuli, and mainly involved flexor muscles of upper extremities. The existence of convergence of somatosensory and acoustic inputs in the brain stem was suggested. This myoclonus seemed to be mediated by a mechanism similar to the spino-bulbo-spinal reflex.

  18. Contact Lens Related Corneal Ulcer

    OpenAIRE

    Loh, KY; Agarwal, P

    2010-01-01

    A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are: overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. Th...

  19. The passive of reflexive verbs in Icelandic

    Directory of Open Access Journals (Sweden)

    Hlíf Árnadóttir

    2011-10-01

    Full Text Available The Reflexive Passive in Icelandic is reminiscent of the so-called New Passive (or New Impersonal in that the oblique case of a passivized object NP is preserved. As is shown by recent surveys, however, speakers who accept the Reflexive Passive do not necessarily accept the New Passive, whereas conversely, speakers who accept the New Passive do also accept the Reflexive Passive. Based on these results we suggest that there is a hierarchy in the acceptance of passive sentences in Icelandic, termed the Passive Acceptability Hierarchy. The validity of this hierarchy is confirmed by our diachronic corpus study of open access digital library texts from Icelandic journals and newspapers dating from the 19th and 20th centuries (tímarit.is. Finally, we sketch an analysis of the Reflexive Passive, proposing that the different acceptability rates of the Reflexive and New Passives lie in the argument status of the object. Simplex reflexive pronouns are semantically dependent on the verbs which select them, and should therefore be analyzed as syntactic arguments only, and not as semantic arguments of these verbs.

  20. Reflexive convention: civil partnership, marriage and family.

    Science.gov (United States)

    Heaphy, Brian

    2017-09-14

    Drawing on an analysis of qualitative interview data from a study of formalized same-sex relationships (civil partnerships) this paper examines the enduring significance of marriage and family as social institutions. In doing so, it intervenes in current debates in the sociology of family and personal life about how such institutions are undermined by reflexivity or bolstered by convention. Against the backdrop of dominating sociological frames for understanding the links between the changing nature of marriage and family and same-sex relationship recognition, the paper analyses the diverse and overlapping ways (including the simple, relational, strategic, ambivalent and critical ways) in which same-sex partners reflexively constructed and engaged with marriage and family conventions. My analysis suggests that instead of viewing reflexivity and convention as mutually undermining, as some sociologists of family and personal life do, it is insightful to explore how diverse forms of reflexivity and convention interact in everyday life to reconfigure the social institutions of marriage and family, but do not undermine them as such. I argue the case for recognizing the ways in which 'reflexive convention', or reflexive investment in convention, contributes to the continuing significance of marriage and family as social institutions. © London School of Economics and Political Science 2017.

  1. A course in lens design

    CERN Document Server

    Velzel, Chris

    2014-01-01

    A Course in Lens Design is an instruction in the design of image-forming optical systems. It teaches how a satisfactory design can be obtained in a straightforward way. Theory is limited to a minimum, and used to support the practical design work. The book introduces geometrical optics, optical instruments and aberrations. It gives a description of the process of lens design and of the strategies used in this process. Half of its content is devoted to the design of sixteen types of lenses, described in detail from beginning to end. This book is different from most other books on lens design because it stresses the importance of the initial phases of the design process: (paraxial) lay-out and (thin-lens) pre-design. The argument for this change of accent is that in these phases much information can be obtained about the properties of the lens to be designed. This information can be used in later phases of the design. This makes A Course in Lens Design a useful self-study book, and a suitable basis for an intro...

  2. Stereoscopic camera design

    Science.gov (United States)

    Montgomery, David J.; Jones, Christopher K.; Stewart, James N.; Smith, Alan

    2002-05-01

    It is clear from the literature that the majority of work in stereoscopic imaging is directed towards the development of modern stereoscopic displays. As costs come down, wider public interest in this technology is expected to increase. This new technology would require new methods of image formation. Advances in stereo computer graphics will of course lead to the creation of new stereo computer games, graphics in films etc. However, the consumer would also like to see real-world stereoscopic images, pictures of family, holiday snaps etc. Such scenery would have wide ranges of depth to accommodate and would need also to cope with moving objects, such as cars, and in particular other people. Thus, the consumer acceptance of auto/stereoscopic displays and 3D in general would be greatly enhanced by the existence of a quality stereoscopic camera. This paper will cover an analysis of existing stereoscopic camera designs and show that they can be categorized into four different types, with inherent advantages and disadvantages. A recommendation is then made with regard to 3D consumer still and video photography. The paper will go on to discuss this recommendation and describe its advantages and how it can be realized in practice.

  3. Gabor lens theory

    International Nuclear Information System (INIS)

    Irani, A.A.

    1978-01-01

    The principle of using the space charge of an electron cloud to focus ion beams was first proposed by Gabor. Electrons are to be confined radially by means of an axial magnetic field B/sub z/ and axially by means of externally applied electric fields E/sub z/. An ion beam of charge density n/sub i/ much less than n/sub e/, the electron charge density can then be focused by the radial electric field set up by the electron cloud. The case considered here is that of a hollow cylindrical conductor charged to a potential +V with grounded rings on either side to set up the axial E/sub z/ field. A solenoid wound around the central conductor supplies the B/sub z/ field. Theoretical calculations are carried out for n/sub e/ maximum as a function of B/sub z/ due to radial confinement and V due to axial confinement and the focal length of the Gabor Lens is calculated

  4. "On Becoming a Critically Reflexive Practitioner" Redux: What Does It Mean to "Be" Reflexive?

    Science.gov (United States)

    Cunliffe, Ann L.

    2016-01-01

    In this commentary, Cunliffe states that is convinced that reflexivity offers a way of foregrounding our moral and ethical responsibility for people and for the world around us. To "BE" reflexive was defined as embracing "subjective understandings of reality as a basis for thinking more critically about the impact of our…

  5. Reflex and Non-Reflex Torque Responses to Stretch of the Human Knee Extensors

    National Research Council Canada - National Science Library

    Mrachacz-Kersting, N

    2001-01-01

    .... The quadriceps muscles were stretched at various background torques, produced either voluntarily or electrically and thus the purely reflex-mediated torque could be calculated. The contribution of the reflex mediated stiffness initially low, increased with increasing background torques for the range of torques investigated.

  6. Positron emission tomography camera

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    A positron emission tomography camera having a plurality of detector planes positioned side-by-side around a patient area to detect radiation. Each plane includes a plurality of photomultiplier tubes and at least two rows of scintillation crystals on each photomultiplier tube extend across to adjacent photomultiplier tubes for detecting radiation from the patient area. Each row of crystals on each photomultiplier tube is offset from the other rows of crystals, and the area of each crystal on each tube in each row is different than the area of the crystals on the tube in other rows for detecting which crystal is actuated and allowing the detector to detect more inter-plane slides. The crystals are offset by an amount equal to the length of the crystal divided by the number of rows. The rows of crystals on opposite sides of the patient may be rotated 90 degrees relative to each other

  7. Junocam: Juno's Outreach Camera

    Science.gov (United States)

    Hansen, C. J.; Caplinger, M. A.; Ingersoll, A.; Ravine, M. A.; Jensen, E.; Bolton, S.; Orton, G.

    2017-11-01

    Junocam is a wide-angle camera designed to capture the unique polar perspective of Jupiter offered by Juno's polar orbit. Junocam's four-color images include the best spatial resolution ever acquired of Jupiter's cloudtops. Junocam will look for convective clouds and lightning in thunderstorms and derive the heights of the clouds. Junocam will support Juno's radiometer experiment by identifying any unusual atmospheric conditions such as hotspots. Junocam is on the spacecraft explicitly to reach out to the public and share the excitement of space exploration. The public is an essential part of our virtual team: amateur astronomers will supply ground-based images for use in planning, the public will weigh in on which images to acquire, and the amateur image processing community will help process the data.

  8. Automatic locking radioisotope camera lock

    International Nuclear Information System (INIS)

    Rosauer, P.J.

    1978-01-01

    The lock of the present invention secures the isotope source in a stored shielded condition in the camera until a positive effort has been made to open the lock and take the source outside of the camera and prevents disconnection of the source pigtail unless the source is locked in a shielded condition in the camera. It also gives a visual indication of the locked or possible exposed condition of the isotope source and prevents the source pigtail from being completely pushed out of the camera, even when the lock is released. (author)

  9. Toward a digital camera to rival the human eye

    Science.gov (United States)

    Skorka, Orit; Joseph, Dileepan

    2011-07-01

    All things considered, electronic imaging systems do not rival the human visual system despite notable progress over 40 years since the invention of the CCD. This work presents a method that allows design engineers to evaluate the performance gap between a digital camera and the human eye. The method identifies limiting factors of the electronic systems by benchmarking against the human system. It considers power consumption, visual field, spatial resolution, temporal resolution, and properties related to signal and noise power. A figure of merit is defined as the performance gap of the weakest parameter. Experimental work done with observers and cadavers is reviewed to assess the parameters of the human eye, and assessment techniques are also covered for digital cameras. The method is applied to 24 modern image sensors of various types, where an ideal lens is assumed to complete a digital camera. Results indicate that dynamic range and dark limit are the most limiting factors. The substantial functional gap, from 1.6 to 4.5 orders of magnitude, between the human eye and digital cameras may arise from architectural differences between the human retina, arranged in a multiple-layer structure, and image sensors, mostly fabricated in planar technologies. Functionality of image sensors may be significantly improved by exploiting technologies that allow vertical stacking of active tiers.

  10. [Contact lens care and maintenance].

    Science.gov (United States)

    Bloise, L

    2017-04-01

    All contact lenses with replacement schedules longer than daily must be maintained. At each step of their use, the lenses may be contaminated. Contact lens solutions perform the essential functions of cleaning, decontaminating and preserving the lenses to prevent infectious problems and improve wearing comfort. Contact lens contamination essentially comes from hands, cleaning solutions, cases, water and the environment. The pathogenic microorganisms are mainly Gram-negative bacteria, fungi and amoebae. Contact lens deposits may or may not have an organic origin. Their presence increases the risk of infection because they serve as a nutrient matrix for microbes, and they are responsible for wearing discomfort. Contact lens solutions differ in their composition, their mechanism of action and the concentration of the various agents. To prescribe the best lens care system to each wearer and for each material, it is necessary to be very familiar with them. Maintenance is the main cause of discomfort with contact lenses, either through improper use, solution-material incompatibility, or a reaction of the wearer to the components. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  11. [Professional outcome of reflex sympathetic dystrophy].

    Science.gov (United States)

    Dauty, M; Renaud, P; Deniaud, C; Tortellier, L; Dubois, C

    2001-03-01

    In spite of physical medicine and rehabilitation care, post-traumatic reflex sympathetic dystrophy can be at the origin of articular deficiency, which decrease the capacity to return to work. The aim of this study is to know the professional future of patients who present post-traumatic reflex sympathetic dystrophy. Eighteen months prospective study, carried out from patients in age to work, hospitalized in physical medicine and rehabilitation unit for ostéo-articular traumatism complicated by reflex sympathetic dystrophy. Description of the population and comorbidity factors preventing professional resumption. Determination of the duration of medical certificate and the modalities of professional resumption. From 16 patients in age to work, only 12 were able to resume a full time profession with an average period of 10.5 months +/- 5. The importance of the, the distale articular location of reflex sympathetic dystrophy (wrist - hand, ankle - foot), the association with a comorbidity such as chronic alcoholism represent pejorative factors of working resumption. Organizations of workstation are often necessary in six cases over eight, if the job is not sedentary. In the most complicated cases, inaptitudes in the work are pronounced with demand of professional reclassifying. Post-traumatic reflex sympathetic dystrophy represents a real challenge for the rehabilitation team, to minimize deficiencies and to help the patient to become again a worker.

  12. Deep-Sea Video Cameras Without Pressure Housings

    Science.gov (United States)

    Cunningham, Thomas

    2004-01-01

    power-supply regulators or filter capacitors were needed, these could be attached in chip form directly onto the back of, and potted with, the imager chip. Because CMOS imagers dissipate little power, the potting would not result in overheating. To minimize the cost of the camera, a fixed lens could be fabricated as part of the plastic case. For improved optical performance at greater cost, an adjustable glass achromatic lens would be mounted in a reservoir that would be filled with transparent oil and subject to the full hydrostatic pressure, and the reservoir would be mounted on the case to position the lens in front of the image sensor. The lens would by adjusted for focus by use of a motor inside the reservoir (oil-filled motors already exist).

  13. Modeling and calibration of a 4-line-camera system for precise coordinate measurement

    Science.gov (United States)

    Zhou, Kai; Wang, Xiangjun

    2017-10-01

    The research in this paper is intended for a precise position measurement system based on 4 line-cameras. Each camera is equipped with a cylindrical lens that can stretch an image point into a line which is perpendicular to the linear CCD, thus providing one dimension of projected coordinate of the corresponding 3D point. This system has a symmetrical structure with four line-cameras being divided into two identical groups. In each group, the two linecameras are fixed together with orientations normal to each other. Those two line-cameras form a 2D image sensor that can determine a light of sight on which the target point lies, just like an area array CCD camera does. With two groups of line-cameras, the position of 3D points can be detected. In this paper, a model of the 4-line-camera system for computing the coordinates of 3D target points in object frame is proposed, which is linear and computationally efficient. In addition, a calibration approach is presented in which the exterior orientations of the four line-cameras are obtained. Experiment results have shown that the system can achieve high accuracy in coordinate measurement of light spots from 0.5m to 3.5m, which demonstrate the performance of our proposed modeling and calibration methods.

  14. The SNAP Strong Lens Survey

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, P.

    2005-01-03

    Basic considerations of lens detection and identification indicate that a wide field survey of the types planned for weak lensing and Type Ia SNe with SNAP are close to optimal for the optical detection of strong lenses. Such a ''piggy-back'' survey might be expected even pessimistically to provide a catalogue of a few thousand new strong lenses, with the numbers dominated by systems of faint blue galaxies lensed by foreground ellipticals. After sketching out our strategy for detecting and measuring these galaxy lenses using the SNAP images, we discuss some of the scientific applications of such a large sample of gravitational lenses: in particular we comment on the partition of information between lens structure, the source population properties and cosmology. Understanding this partitioning is key to assessing strong lens cosmography's value as a cosmological probe.

  15. Automated Fresnel lens tester system

    Energy Technology Data Exchange (ETDEWEB)

    Phipps, G.S.

    1981-07-01

    An automated data collection system controlled by a desktop computer has been developed for testing Fresnel concentrators (lenses) intended for solar energy applications. The system maps the two-dimensional irradiance pattern (image) formed in a plane parallel to the lens, whereas the lens and detector assembly track the sun. A point detector silicon diode (0.5-mm-dia active area) measures the irradiance at each point of an operator-defined rectilinear grid of data positions. Comparison with a second detector measuring solar insolation levels results in solar concentration ratios over the image plane. Summation of image plane energies allows calculation of lens efficiencies for various solar cell sizes. Various graphical plots of concentration ratio data help to visualize energy distribution patterns.

  16. Compliance among soft contact lens wearers.

    Science.gov (United States)

    Kuzman, Tomislav; Kutija, Marija Barisić; Masnec, Sanja; Jandroković, Sonja; Mrazovac, Danijela; Jurisić, Darija; Skegro, Ivan; Kalauz, Miro; Kordić, Rajko

    2014-12-01

    Contact lens compliance is proven to be crucial for preventing lens wear-related complications because of the interdependence of the steps in lens care regime and their influence on lens system microbial contamination. Awareness of the patients' lens handling compliance as well as correct recognition of non-compliant behaviours is the basis for creating more targeted strategies for patient education. The aim of this study was to investigate compliance among soft contact lens (SCL) wearers in different aspects of lens care handling and wearing habits. In our research 50 asymptomatic lens wearers filled out a questionnaire containing demographic data, lens type, hygiene and wearing habits, lenses and lens care system replacement schedule and self-evaluation of contact lens handling hygiene. We established criteria of compliance according to available manufacturer's recommendations, prior literature and our clinical experience. Only 2 (4%) of patients were fully compliant SCL wearers. The most common non-compliant behaviours were insufficient lens solution soaking time (62%), followed by failure to daily exchange lens case solution and showering while wearing lenses. 44% of patients reported storing lenses in saline solution. Mean lens storage case replacement was 3.6 months, with up to 78% patients replacing lens case at least once in 3 months. Average grade in self evaluating level of compliance was very good (4 +/- 0.78) (from 1-poor level of hygiene to 5-great level of hygiene). Lens wearers who reported excessive daily lens wear and more than 10 years of lens wearing experience were also found to be less compliant with other lens system care procedures. (t = -2.99, df=47, p lens system maintenance steps. Most common non-compliant behaviours were the ones that are crucial for maintaining lens sterility and preventing infection. Despite the low objective compliance rate, self grading was relatively high. Therefore, these results indicate the need for patient

  17. An electrically tunable plenoptic camera using a liquid crystal microlens array

    International Nuclear Information System (INIS)

    Lei, Yu; Tong, Qing; Zhang, Xinyu; Sang, Hongshi; Ji, An; Xie, Changsheng

    2015-01-01

    Plenoptic cameras generally employ a microlens array positioned between the main lens and the image sensor to capture the three-dimensional target radiation in the visible range. Because the focal length of common refractive or diffractive microlenses is fixed, the depth of field (DOF) is limited so as to restrict their imaging capability. In this paper, we propose a new plenoptic camera using a liquid crystal microlens array (LCMLA) with electrically tunable focal length. The developed LCMLA is fabricated by traditional photolithography and standard microelectronic techniques, and then, its focusing performance is experimentally presented. The fabricated LCMLA is directly integrated with an image sensor to construct a prototyped LCMLA-based plenoptic camera for acquiring raw radiation of targets. Our experiments demonstrate that the focused region of the LCMLA-based plenoptic camera can be shifted efficiently through electrically tuning the LCMLA used, which is equivalent to the extension of the DOF

  18. An electrically tunable plenoptic camera using a liquid crystal microlens array

    Energy Technology Data Exchange (ETDEWEB)

    Lei, Yu [National Key Laboratory of Science and Technology on Multispectral Information Processing, Huazhong University of Science and Technology, Wuhan 430074 (China); School of Automation, Huazhong University of Science and Technology, Wuhan 430074 (China); Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074 (China); Shijiazhuang Tiedao University, Shijiazhuang 050043 (China); Tong, Qing; Zhang, Xinyu [National Key Laboratory of Science and Technology on Multispectral Information Processing, Huazhong University of Science and Technology, Wuhan 430074 (China); School of Automation, Huazhong University of Science and Technology, Wuhan 430074 (China); Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074 (China); Sang, Hongshi [National Key Laboratory of Science and Technology on Multispectral Information Processing, Huazhong University of Science and Technology, Wuhan 430074 (China); School of Automation, Huazhong University of Science and Technology, Wuhan 430074 (China); Ji, An [Institute of Semiconductors, Chinese Academy of Science, Beijing 100083 (China); Xie, Changsheng [Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2015-05-15

    Plenoptic cameras generally employ a microlens array positioned between the main lens and the image sensor to capture the three-dimensional target radiation in the visible range. Because the focal length of common refractive or diffractive microlenses is fixed, the depth of field (DOF) is limited so as to restrict their imaging capability. In this paper, we propose a new plenoptic camera using a liquid crystal microlens array (LCMLA) with electrically tunable focal length. The developed LCMLA is fabricated by traditional photolithography and standard microelectronic techniques, and then, its focusing performance is experimentally presented. The fabricated LCMLA is directly integrated with an image sensor to construct a prototyped LCMLA-based plenoptic camera for acquiring raw radiation of targets. Our experiments demonstrate that the focused region of the LCMLA-based plenoptic camera can be shifted efficiently through electrically tuning the LCMLA used, which is equivalent to the extension of the DOF.

  19. UCXp camera imaging principle and key technologies of data post-processing

    International Nuclear Information System (INIS)

    Yuan, Fangyan; Li, Guoqing; Zuo, Zhengli; Liu, Jianmin; Wu, Liang; Yu, Xiaoping; Zhao, Haitao

    2014-01-01

    The large format digital aerial camera product UCXp was introduced into the Chinese market in 2008, the image consists of 17310 columns and 11310 rows with a pixel size of 6 mm. The UCXp camera has many advantages compared with the same generation camera, with multiple lenses exposed almost at the same time and no oblique lens. The camera has a complex imaging process whose principle will be detailed in this paper. On the other hand, the UCXp image post-processing method, including data pre-processing and orthophoto production, will be emphasized in this article. Based on the data of new Beichuan County, this paper will describe the data processing and effects

  20. The Eye of the Camera

    NARCIS (Netherlands)

    van Rompay, Thomas Johannes Lucas; Vonk, Dorette J.; Fransen, M.L.

    2009-01-01

    This study addresses the effects of security cameras on prosocial behavior. Results from previous studies indicate that the presence of others can trigger helping behavior, arising from the need for approval of others. Extending these findings, the authors propose that security cameras can likewise

  1. Reflexive Planning as Design and Work

    DEFF Research Database (Denmark)

    Lissandrello, Enza; Grin, John

    2011-01-01

    In recent years, planning theorists have advanced various interpretations of the notion of reflexivity, inspired by American pragmatism, complexity theory, hermeneutics, discursive and collaborative planning. Scholars agree that “reflexivity” has a strong temporal dimension: it not only aims...... to solve present planning problems, but to imagine and understand alternative trajectories for future action. This article explores the practical utility of reflexivity for planners, through a case study that focuses on a project to promote sustainable development in the Port of Amsterdam. Reflexivity...... in planning emerges as a new tool for generating critical knowledge and dialogue that can synthesise the perspectives of multiple actors in a common understanding, existing structural constraints and a collective imagination of alternative future possibilities. Such research highlights the potential...

  2. Orthodoxy and reflexivity in international comparative analysis

    DEFF Research Database (Denmark)

    Lind, Jens; Valkenburg, Ben

    2002-01-01

    This contribution aims at four points.First we want to argue why we think a reflexive social science is more adequate than the orthodox consensus. In current practice much of the criticism on the orthodox consensus is shared on a theoretical level, without considering the implications and acting...... upon the consequences on the level of empirical research. We want to avoid that, so our second and third subject will be the practical implications of reflexivity for empirical research as well as for social policy. Our discussion on these subjects is based on the practical experiences in the INPART...... project, in which we have tried to deal with these consequences. Fourth, and hopefully as a result of the first three aims, we want to argue that a reflexive approach of international, comparative research is not only desirable, but attainable as well. In order to do so, we begin with a short discussion...

  3. Reflex sympathetic dystrophy: reflections from a clinician.

    Science.gov (United States)

    Small, Eric

    2007-05-01

    Reflex sympathetic dystrophy is defined as chronic musculoskeletal pain and autonomic dysfunction. It is a difficult diagnosis to make, and the adolescent often sees many specialists before arriving at the correct diagnosis. In this article I review reflex sympathetic dystrophy and reflect on the differential diagnosis, pertinent medical history, personal characteristics of patients with reflex sympathetic dystrophy, physical examination, and laboratory evaluation. Principles of management are considered, including physical therapy, pharmacology, psychological therapy, and alternative therapies. Accurate diagnosis and management are critical for not prolonging the adolescent's and the family's suffering. It is important to provide aggressive physical therapy, stress management, relaxation training, and close follow-up. It is also critical to avoid immobilization, surgery, or invasive procedures and unnecessary tests.

  4. Computer-aided lens assembly

    Science.gov (United States)

    Tomlinson, Richard; Alcock, Rob; Petzing, Jon; Coupland, Jeremy

    2004-01-01

    We propose a computer-aided method of lens manufacture that allows assembly, adjustment, and test phases to be run concurrently until an acceptable level of optical performance is reached. Misalignment of elements within a compound lens is determined by a comparison of the results of physical ray tracing by use of an array of Gaussian laser beams with numerically obtained geometric ray traces. An estimate of misalignment errors is made, and individual elements are adjusted in an iterative manner until performance criteria are achieved. The method is illustrated for the alignment of an air-spaced doublet.

  5. Acanthamoeba keratitis. Contact lens and noncontact lens characteristics.

    Science.gov (United States)

    Chynn, E W; Lopez, M A; Pavan-Langston, D; Talamo, J H

    1995-09-01

    To identify potential differences in time to diagnosis and final visual outcome between contact lens and noncontact lens users with Acanthamoeba keratitis. Prior studies have shown early diagnosis and therapy to be related to outcome but have not analyzed differences among patients with and without contact lenses. A retrospective analysis of 11 consecutive cases (involving 13 eyes) of Acanthamoeba keratitis diagnosed at one institution over a 3-year period. Mean time to diagnosis was significantly longer in noncontact lens users versus those who wore contact lenses (mean, 5.8 versus 3.3 weeks). Fifty percent of patients who did not wear contact lenses had a poor outcome (visual acuity worse than 20/40 or penetrating keratoplasty) versus 14% of patients who wore contact lenses. Diagnoses were made later in patients without contact lenses, and these patients had a worse visual outcome than those with Acanthamoeba keratitis who wore contact lenses. All patients with unresponsive microbial keratitis, even those without contact lens use, should be evaluated for Acanthamoeba.

  6. Munchausen's syndrome simulating reflex sympathetic dystrophy.

    Science.gov (United States)

    Rodriguez-Moreno, J; Ruiz-Martin, J M; Mateo-Soria, L; Rozadilla, A; Roig-Escofet, D

    1990-01-01

    A 15 year old girl who had pain, oedema of her left hand, and fever of four months' duration is described. Marked demineralisation of her hand was shown by radiography, and increased articular uptake by technetium-99m bone scan. All these changes were indistinguishable from reflex sympathetic dystrophy. After two admissions to hospital and multiple explorations we discovered that she had induced her symptoms herself and a diagnosis of Munchausen's syndrome was made. As far as we know this presentation has not been previously reported and might help to explain the physiopathology of some signs of reflex sympathetic dystrophy. Images PMID:2270960

  7. Probabilities on Streams and Reflexive Games

    Directory of Open Access Journals (Sweden)

    Andrew Schumann

    2014-01-01

    Full Text Available Probability measures on streams (e.g. on hypernumbers and p-adic numbers have been defined. It was shown that these probabilities can be used for simulations of reflexive games. In particular, it can be proved that Aumann's agreement theorem does not hold for these probabilities. Instead of this theorem, there is a statement that is called the reflexion disagreement theorem. Based on this theorem, probabilistic and knowledge conditions can be defined for reflexive games at various reflexion levels up to the infinite level. (original abstract

  8. Gamma camera system

    International Nuclear Information System (INIS)

    Miller, D.W.; Gerber, M.S.

    1982-01-01

    The invention provides a composite solid state detector for use in deriving a display, by spatial coordinate information, of the distribution or radiation emanating from a source within a region of interest, comprising several solid state detector components, each having a given surface arranged for exposure to impinging radiation and exhibiting discrete interactions therewith at given spatially definable locations. The surface of each component and the surface disposed opposite and substantially parallel thereto are associated with impedence means configured to provide for each opposed surface outputs for signals relating the given location of the interactions with one spatial coordinate parameter of one select directional sense. The detector components are arranged to provide groupings of adjacently disposed surfaces mutually linearly oriented to exhibit a common directional sense of the spatial coordinate parameter. Means interconnect at least two of the outputs associated with each of the surfaces within a given grouping for collecting the signals deriving therefrom. The invention also provides a camera system for imaging the distribution of a source of gamma radiation situated within a region of interest

  9. The stretch reflex and the contributions of C David Marsden.

    Science.gov (United States)

    Bhattacharyya, Kalyan B

    2017-01-01

    The stretch reflex or myotatic reflex refers to the contraction of a muscle in response to its passive stretching by increasing its contractility as long as the stretch is within physiological limits. For ages, it was thought that the stretch reflex was of short latency and it was synonymous with the tendon reflex, subserving the same spinal reflex arc. However, disparities in the status of the two reflexes in certain clinical situations led Marsden and his collaborators to carry out a series of experiments that helped to establish that the two reflexes had different pathways. That the two reflexes are dissociated has been proved by the fact that the stretch reflex and the tendon reflex, elicited by stimulation of the same muscle, have different latencies, that of the stretch reflex being considerably longer. They hypothesized that the stretch reflex had a transcortical course before it reached the spinal motor neurons for final firing. Additionally, the phenomenon of stimulus-sensitive cortical myoclonus lent further evidence to the presence of the transcortical loop where the EEG correlate preceded the EMG discharge. This concept has been worked out by later neurologists in great detail, and the general consensus is that indeed, the stretch reflex is endowed with a conspicuous transcortical component.

  10. The stretch reflex and the contributions of C David Marsden

    Directory of Open Access Journals (Sweden)

    Kalyan B Bhattacharyya

    2017-01-01

    Full Text Available The stretch reflex or myotatic reflex refers to the contraction of a muscle in response to its passive stretching by increasing its contractility as long as the stretch is within physiological limits. For ages, it was thought that the stretch reflex was of short latency and it was synonymous with the tendon reflex, subserving the same spinal reflex arc. However, disparities in the status of the two reflexes in certain clinical situations led Marsden and his collaborators to carry out a series of experiments that helped to establish that the two reflexes had different pathways. That the two reflexes are dissociated has been proved by the fact that the stretch reflex and the tendon reflex, elicited by stimulation of the same muscle, have different latencies, that of the stretch reflex being considerably longer. They hypothesized that the stretch reflex had a transcortical course before it reached the spinal motor neurons for final firing. Additionally, the phenomenon of stimulus-sensitive cortical myoclonus lent further evidence to the presence of the transcortical loop where the EEG correlate preceded the EMG discharge. This concept has been worked out by later neurologists in great detail , and the general consensus is that indeed, the stretch reflex is endowed with a conspicuous transcortical component.

  11. Charitable giving and reflexive individuals: How personal reflexivity mediates between structure and agency.

    Science.gov (United States)

    Sanghera, Balihar

    2017-03-01

    This article examines how individuals are reflexive beings who interpret the world in relation to things that matter to them, and how charitable acts are evaluated and embedded in their lives with different degrees of meaning and importance. Rather than framing the discussion of charitable practices in terms of an altruism/egoism binary or imputing motivations and values to social structures, the article explains how reflexivity is an important and neglected dimension of social practices, and how it interacts with sympathy, sentiments and discourses to shape giving. The study also shows that there are different modes of reflexivity, which have varied effects on charity and volunteering.

  12. A microcapillary lens for X-rays

    CERN Document Server

    Dudchik, Y I

    1999-01-01

    A new design of a compound refractive lens for X-rays is proposed. The lens is made as a set of glue microlenses placed in a glass capillary. The technique of lens fabrication is described. Results of ray tracing calculations for 8 and 15 keV photons are represented.

  13. First results of micro-neutron tomography by use of a focussing neutron lens

    CERN Document Server

    Masschaele, B; Cauwels, P; Dierick, M; Jolie, J; Mondelaers, W

    2001-01-01

    Since the appearance of high flux neutron beams, scientists experimented with neutron radiography. This high beam flux combined with modern neutron to visible light converters leads to the possibility of performing fast neutron micro-tomography. The first results of cold neutron tomography with a neutron lens are presented in this article. Samples are rotated in the beam and the projections are recorded with a neutron camera. The 3D reconstruction is performed with cone beam reconstruction software.

  14. Camera Calibration for Water-Biota Research: The Projected Area of Vegetation

    Directory of Open Access Journals (Sweden)

    Rene Wackrow

    2015-12-01

    Full Text Available Imaging systems have an indisputable role in revealing vegetation posture under diverse flow conditions, image sequences being generated with off the shelf digital cameras. Such sensors are cheap but introduce a range of distortion effects, a trait only marginally tackled in hydraulic studies focusing on water-vegetation dependencies. This paper aims to bridge this gap by presenting a simple calibration method to remove both camera lens distortion and refractive effects of water. The effectiveness of the method is illustrated using the variable projected area, computed for both simple and complex shaped objects. Results demonstrate the significance of correcting images using a combined lens distortion and refraction model, prior to determining projected areas and further data analysis. Use of this technique is expected to increase data reliability for future work on vegetated channels.

  15. A simple measurement hammer for quantitative reflex studies

    NARCIS (Netherlands)

    Stam, J.; van Leeuwen, J. R.

    1984-01-01

    A reflex hammer for measurement of the mechanical stimulus strength was designed. Combined with standard EMG equipment this instrument permits the study of both stimulus-response relations and latencies of myotatic reflexes. Some results in normal subjects are discussed

  16. Comparison of Stretch Reflex Torques in Ankle Dorsiflexors and Plantarflexors

    National Research Council Canada - National Science Library

    Tung, J

    2001-01-01

    ...) ankle muscles, Pulse, step, and a combination of random perturbation and step inputs were used to identify the reflex and intrinsic contributions to the measured torque, TA reflex torques were very...

  17. The Ultrawideband Leaky Lens Antenna

    NARCIS (Netherlands)

    Bruni, S.; Neto, A.; Marliani, F.

    2007-01-01

    A novel directive and nondispersive antenna is presented: the ultrawideband (UWB) leaky lens. It is based on the broad band Cherenkov radiation occurring at a slot printed between different infinite homogeneous dielectrics. The first part of the paper presents the antenna concept and the UWB design.

  18. ECTOPIC LENS EXTRACTION IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Vladimir Pfeifer

    2002-12-01

    Full Text Available Background. Ectopia lentis continues to be a therapeutic challenge for ophthalmologists. It can occur as an isolated condition, after ocular trauma, in association with other ocular disorders, as part of a systemic mesodermal disease or a complication of general metabolic disorders. Minimal subluxation of the lens may cause no visual symptoms, but in more advanced cases serious optical disturbances arise. The most important is amblyopia. Surgical treatment options include iris manipulation, lens discission, aspiration, intracapsular or extracapsular extraction, and pars plana lensectomy. The choice of surgical technique remains controversial, in part because of the historically poor visual results and high rate of perioperative complications, including vitreous loss and retinal detachment.Methods. We describe a surgical technique based on the use of the Cionni endocapsular tension ring, dry irrigation aspiration of lens material, centration of the capsular bag and foldable intraocular lens implantation into the bag. With mentioned surgical technique 8 patients were operated; 4 boys and 4 girls, together 11 eyes.Results. The final BCVA after follow up period improved in 9 eyes and it remained the same as before operation in one eye. Statistical comparison of preoperative and postoperative visual acuities showed significant improvement. On the other hand there was no correlation between preoperative and postoperative visual acuity.Conclusions. This surgical procedure is an alternative approach in solving this challenging cases of ectopia lentis with good postoperative visual rehabilitation.

  19. Spinning pipe gas lens revisited

    CSIR Research Space (South Africa)

    Mafusire, C

    2008-01-01

    Full Text Available , there is little information on optical phase aberrations and no study to date on the propagation parameters of the laser beam, but has rather remained rooted in the domain of ray optics. Researchers revisit the spinning pipe gas lens in this paper with new...

  20. Tube entrance lens focus control

    Science.gov (United States)

    Weisser, D. C.; Fifield, L. K.; Kitchen, T. F. G.; Tunningley, T. B.; Lobanov, N. R.; Muirhead, A. G.

    2013-02-01

    The entrance of the accelerator tube in a large electrostatic accelerator imposes a strong lens that dominates the beam optics. The magnification of the lens is large because of the low injection energy, the high voltage gradient of the acceleration tube and the long distance to the terminal. In the absence of the acceleration, the magnification would produce an unacceptably large beam spot at the terminal. The tyranny of the lens is especially irksome when the accelerator is required to operate at a lower terminal voltage than the one corresponding to the nominal gradient at high voltage. One way around the difficulty, used in NEC Pelletron accelerators, is to insert a series of nylon and steel rods that short together units of the acceleration structure at the terminal leaving the ones near the entrance close to the nominal gradient for optimum transmission. This operation takes time and risks the loss of insulating gas. Another alternative used in the 25URC at Oak Ridge National Laboratory, is to focus the beam at the tube entrance, substantially diluting the effect of the entrance lens. The beam then diverges and so requires an additional lens part way to the terminal. This solution is only partially effective and still necessitates use of shorting rods for low voltage operation. The fact that these elaborate strategies are used is evidence that the alternative of lowering the injection energy as the terminal voltage is lowered imposes enough problems that it is not used in practice. We have modeled a solution that controls the voltage gradient at the tube entrance using an external power supply. This not only maintains the focusing effect of the lens but provides the opportunity to tune the beam by adjusting the entrance lens. A 150 kV power supply outside the pressure vessel feeds a controllable voltage through a high voltage feed-through to the fifth electrode of the accelerator tube. Thus 150 kV on this electrode creates the nominal gradient of 30 kV per

  1. CCD TV camera, TM1300

    International Nuclear Information System (INIS)

    Takano, Mitsuo; Endou, Yukio; Nakayama, Hideo

    1982-01-01

    Development has been made of a black-and-white TV camera TM 1300 using an interline-transfer CCD, which excels in performance frame-transfer CCDs marketed since 1980: it has a greater number of horizontal picture elements and far smaller input power (less than 2 W at 9 V), uses hybrid ICs for the CCD driver unit to reduce the size of the camera, has no picture distortion, no burn-in; in addition, it has peripheral equipment, such as the camera housing and the pan and till head miniaturized as well. It is also expected to be widened in application to industrial TV. (author)

  2. High Quality Camera Surveillance System

    OpenAIRE

    Helaakoski, Ari

    2015-01-01

    Oulu University of Applied Sciences Information Technology Author: Ari Helaakoski Title of the master’s thesis: High Quality Camera Surveillance System Supervisor: Kari Jyrkkä Term and year of completion: Spring 2015 Number of pages: 31 This master’s thesis was commissioned by iProtoXi Oy and it was done to one iProtoXi customer. The aim of the thesis was to make a camera surveillance system which is using a High Quality camera with pan and tilt possibility. It should b...

  3. Control system for gamma camera

    International Nuclear Information System (INIS)

    Miller, D.W.

    1977-01-01

    An improved gamma camera arrangement is described which utilizing a solid state detector, formed of high purity germanium. the central arrangement of the camera operates to effect the carrying out of a trapezoidal filtering operation over antisymmetrically summed spatial signals through gated integration procedures utilizing idealized integrating intervals. By simultaneously carrying out peak energy evaluation of the input signals, a desirable control over pulse pile-up phenomena is achieved. Additionally, through the use of the time derivative of incoming pulse or signal energy information to initially enable the control system, a low level information evaluation is provided serving to enhance the signal processing efficiency of the camera

  4. Biological Motion Cues Trigger Reflexive Attentional Orienting

    Science.gov (United States)

    Shi, Jinfu; Weng, Xuchu; He, Sheng; Jiang, Yi

    2010-01-01

    The human visual system is extremely sensitive to biological signals around us. In the current study, we demonstrate that biological motion walking direction can induce robust reflexive attentional orienting. Following a brief presentation of a central point-light walker walking towards either the left or right direction, observers' performance…

  5. On Becoming a Critically Reflexive Practitioner

    Science.gov (United States)

    Cunliffe, Ann L.

    2004-01-01

    Critically reflexive practice embraces subjective understandings of reality as a basis for thinking more critically about the impact of our assumptions, values, and actions on others. Such practice is important to management education, because it helps us understand how we constitute our realities and identities in relational ways and how we can…

  6. Bases for Cones and Reflexivity | Polyrakis | Quaestiones ...

    African Journals Online (AJOL)

    It is proved that a Banach space E is non-reflexive if and only if E has a closed cone with an unbounded, closed, dentable base. If E is a Banach lattice, the same characterization holds with the extra assumption that the cone is contained in E+. This article is also a survey of the geometry (dentability) of bases for cones.

  7. Reflexivity on Banach Spaces of Analytic Functions

    Directory of Open Access Journals (Sweden)

    B. Yousefi and J. Doroodgar

    2008-03-01

    Full Text Available . Let X be a Banach space of functions analytic on a plane domain Ω such that for every λ in Ω the functional of evaluation at λ is bounded. Assume further that X contains the constants and admits multiplication by the independent variable z, Mz, as a bounded operator. We give sufficient conditions for Mz to be reflexive.

  8. Reflex epilepsy: triggers and management strategies

    Directory of Open Access Journals (Sweden)

    Okudan ZV

    2018-01-01

    Full Text Available Zeynep Vildan Okudan,1 Çiğdem Özkara2 1Department of Neurology, Bakirkoy Dr Sadi Konuk Education and Research Hospital, 2Department of Neurology and Clinical Neurophysiology, Cerrahpasa Faculty of Medicine, University of Istanbul, Istanbul, Turkey Abstract: Reflex epilepsies (REs are identified as epileptic seizures that are consistently induced by identifiable and objective-specific triggers, which may be an afferent stimulus or by the patient’s own activity. RE may have different subtypes depending on the stimulus characteristic. There are significant clinical and electrophysiologic differences between different RE types. Visual stimuli-sensitive or photosensitive epilepsies constitute a large proportion of the RE and are mainly related to genetic causes. Reflex epilepsies may present with focal or generalized seizures due to specific triggers, and sometimes seizures may occur spontaneously. The stimuli can be external (light flashes, hot water, internal (emotion, thinking, or both and should be distinguished from triggering precipitants, which most epileptic patients could report such as emotional stress, sleep deprivation, alcohol, and menstrual cycle. Different genetic and acquired factors may play a role in etiology of RE. This review will provide a current overview of the triggering factors and management of reflex seizures. Keywords: seizure, reflex epilepsy, photosensitivity, hot water, reading, thinking

  9. Reflectivity, Reflexivity and Situated Reflective Practice

    Science.gov (United States)

    Malthouse, Richard; Roffey-Barentsen, Jodi; Watts, Mike

    2014-01-01

    This paper describes an aspect of reflective practice referred to as situated reflective practice. The overarching theory is derived from social theories of structuration and reflexivity. In particular, from Giddens' theory of structuration, which sees social life as an interplay of agency and structure. Discussion of the research reported here…

  10. Blink reflex in type 2 diabetes mellitus.

    Science.gov (United States)

    Elkholy, Saly H; Hosny, Hanan M; Shalaby, Nevein M; El-Hadidy, Reem A; Abd El-Rahim, Noha T; Mohamed, Manal M

    2014-12-01

    An evaluation of the extent of damage of the central nervous system in diabetes mellitus is of high value in current research. Electrophysiological abnormalities are frequently present in asymptomatic patients with diabetes mellitus. Diabetic cranial neuropathy is one of the complications of the disease. Blink reflex is used to diagnose subclinical cranial neuropathy. The objective is to test the utility of blink reflex in detecting subclinical cranial nerve involvement in patients with type 2 diabetes mellitus. Forty patients with type 2 diabetes mellitus, aged from 30 to 60 years examined clinically and neurologically. Blink reflex and nerve conduction studies for the upper and lower limbs were performed and compared with 20 matched normal controls. Diabetic patients with peripheral neuropathy showed significant prolonged distal latency and reduced amplitudes of the R2C response compared with the control, patients without peripheral neuropathy showed insignificant changes. Alteration of R2 correlated with the type of treatment and the duration of the disease. In patients without peripheral neuropathy, ulnar sensory distal latencies showed significant positive correlation with R2I latency, whereas its Conduction Velocity (CV) showed significant positive correlation with R2C amplitudes and negative correlation with R2C latency. R2C is the most sensitive parameter in the blink reflex, which can help in the diagnosis of subclinical diabetic cranial neuropathy.

  11. The acoustic reflex threshold in aging ears.

    Science.gov (United States)

    Silverman, C A; Silman, S; Miller, M H

    1983-01-01

    This study investigates the controversy regarding the influence of age on the acoustic reflex threshold for broadband noise, 500-, 1000-, 2000-, and 4000-Hz activators between Jerger et al. [Mono. Contemp. Audiol. 1 (1978)] and Jerger [J. Acoust. Soc. Am. 66 (1979)] on the one hand and Silman [J. Acoust. Soc. Am. 66 (1979)] and others on the other. The acoustic reflex thresholds for broadband noise, 500-, 1000-, 2000-, and 4000-Hz activators were evaluated under two measurement conditions. Seventy-two normal-hearing ears were drawn from 72 subjects ranging in age from 20-69 years. The results revealed that age was correlated with the acoustic reflex threshold for BBN activator but not for any of the tonal activators; the correlation was stronger under the 1-dB than under the 5-dB measurement condition. Also, the mean acoustic reflex thresholds for broadband noise activator were essentially similar to those reported by Jerger et al. (1978) but differed from those obtained in this study under the 1-dB measurement condition.

  12. Lens stem cells may reside outside the lens capsule: an hypothesis

    Directory of Open Access Journals (Sweden)

    Meyer Rita A

    2007-06-01

    Full Text Available Abstract In this paper, we consider the ocular lens in the context of contemporary developments in biological ideas. We attempt to reconcile lens biology with stem cell concepts and a dearth of lens tumors. Historically, the lens has been viewed as a closed system, in which cells at the periphery of the lens epithelium differentiate into fiber cells. Theoretical considerations led us to question whether the intracapsular lens is indeed self-contained. Since stem cells generate tumors and the lens does not naturally develop tumors, we reasoned that lens stem cells may not be present within the capsule. We hypothesize that lens stem cells reside outside the lens capsule, in the nearby ciliary body. Our ideas challenge the existing lens biology paradigm. We begin our discussion with lens background information, in order to describe our lens stem cell hypothesis in the context of published data. Then we present the ciliary body as a possible source for lens stem cells, and conclude by comparing the ocular lens with the corneal epithelium.

  13. New Molecular Knowledge Towards the Trigemino-Cardiac Reflex as a Cerebral Oxygen-Conserving Reflex

    Directory of Open Access Journals (Sweden)

    N. Sandu

    2010-01-01

    Full Text Available The trigemino-cardiac reflex (TCR represents the most powerful of the autonomous reflexes and is a subphenomenon in the group of the so-called “oxygen-conserving reflexes”. Within seconds after the initiation of such a reflex, there is a powerful and differentiated activation of the sympathetic system with subsequent elevation in regional cerebral blood flow (CBF, with no changes in the cerebral metabolic rate of oxygen (CMRO2 or in the cerebral metabolic rate of glucose (CMRglc. Such an increase in regional CBF without a change of CMRO2 or CMRglc provides the brain with oxygen rapidly and efficiently. Features of the reflex have been discovered during skull base surgery, mediating reflex protection projects via currently undefined pathways from the rostral ventrolateral medulla oblongata to the upper brainstem and/or thalamus, which finally engage a small population of neurons in the cortex. This cortical center appears to be dedicated to transduce a neuronal signal reflexively into cerebral vasodilatation and synchronization of electrocortical activity; a fact that seems to be unique among autonomous reflexes. Sympathetic excitation is mediated by cortical-spinal projection to spinal preganglionic sympathetic neurons, whereas bradycardia is mediated via projections to cardiovagal motor medullary neurons. The integrated reflex response serves to redistribute blood from viscera to the brain in response to a challenge to cerebral metabolism, but seems also to initiate a preconditioning mechanism. Previous studies showed a great variability in the human TCR response, in special to external stimuli and individual factors. The TCR gives, therefore, not only new insights into novel therapeutic options for a range of disorders characterized by neuronal death, but also into the cortical and molecular organization of the brain.

  14. Short reflex expirations (expiration reflexes) induced by mechanical stimulation of the trachea in anesthetized cats

    OpenAIRE

    Poliacek, Ivan; Rose, Melanie J; Corrie, Lu Wen-Chi; Wang, Cheng; Jakus, Jan; Barani, Helena; Stransky, Albert; Polacek, Hubert; Halasova, Erika; Bolser, Donald C

    2008-01-01

    Fifty spontaneously breathing pentobarbital-anesthetized cats were used to determine the incidence rate and parameters of short reflex expirations induced by mechanical stimulation of the tracheal mucosa (ERt). The mechanical stimuli evoked coughs; in addition, 67.6% of the stimulation trials began with ERt. The expiration reflex mechanically induced from the glottis (ERg) was also analyzed (99.5% incidence, p < 0.001 compared to the incidence of ERt). We found that the amplitudes of abdomina...

  15. Modern lens antennas for communications engineering

    CERN Document Server

    Thornton, John

    2012-01-01

    The aim of this book is to present the modern design principles and analysis of lens antennas. It gives graduates and RF/Microwave professionals the design insights in order to make full use of lens antennas.  Why do we want to write a book in lens antennas? Because this topic has not been thoroughly publicized, its importance is underestimated. As antennas play a key role in communication systems, recent development in wireless communications would indeed benefit from the characteristics of lens antennas: low profile, and low cost etc.  The major advantages of lens antennas are na

  16. Effects of isoflurane on the baroreceptor reflex.

    Science.gov (United States)

    Seagard, J L; Elegbe, E O; Hopp, F A; Bosnjak, Z J; von Colditz, J H; Kalbfleisch, J H; Kampine, J P

    1983-12-01

    The baroreceptor reflex has been found to be attenuated during anesthesia, but the effects of the relatively new anesthetic, isoflurane, on baroreflex function have not been examined thoroughly. This study was performed to determine the effects of isoflurane on each component of the baroreceptor reflex arc, including the receptors, afferent and efferent nerve pathways, central integratory centers, peripheral ganglia, and the heart. Baroreflex effects on heart rate initiated by systemic pressure changes were examined in conscious and anesthetized dogs (1.3% and 2.6% isoflurane). The effects on individual components of the reflex arc were determined by examining carotid sinus baroreceptor afferent activity, sympathetic efferent nerve activity, and heart rate response to direct sympathetic and parasympathetic efferent nerve stimulation in anesthetized dogs. Preganglionic and postganglionic nerve activities were recorded simultaneously during baroreflex activation to determine ganglionic effects of isoflurane. Baroreflex-induced changes in heart rate were not depressed significantly until 2.6% isoflurane if blood pressure changes due to anesthetic administration were prevented. Significant decreases in baseline sympathetic efferent nerve activity were found at 1.3% and 2.6% isoflurane, with depression of postganglionic activity significantly greater than preganglionic activity at 2.6% isoflurane, indicating a ganglionic effect of isoflurane. Cardiac chronotropic responses to direct stimulation of sympathetic and vagal fibers were attenuated significantly by isoflurane, with sympathetic stimulation showing the greater sensitivity to the anesthetic. Carotid baroreceptor afferent activity was increased by isoflurane, and this sensitization of the baroreceptors appeared to contribute to the decreased levels of sympathetic tone. Therefore, although isoflurane was found to alter the baroreceptor reflex through its effects at multiple sites of the baroreflex arc, significant

  17. Variable high-resolution color CCD camera system with online capability for professional photo studio application

    Science.gov (United States)

    Breitfelder, Stefan; Reichel, Frank R.; Gaertner, Ernst; Hacker, Erich J.; Cappellaro, Markus; Rudolf, Peter; Voelk, Ute

    1998-04-01

    Digital cameras are of increasing significance for professional applications in photo studios where fashion, portrait, product and catalog photographs or advertising photos of high quality have to be taken. The eyelike is a digital camera system which has been developed for such applications. It is capable of working online with high frame rates and images of full sensor size and it provides a resolution that can be varied between 2048 by 2048 and 6144 by 6144 pixel at a RGB color depth of 12 Bit per channel with an also variable exposure time of 1/60s to 1s. With an exposure time of 100 ms digitization takes approx. 2 seconds for an image of 2048 by 2048 pixels (12 Mbyte), 8 seconds for the image of 4096 by 4096 pixels (48 Mbyte) and 40 seconds for the image of 6144 by 6144 pixels (108 MByte). The eyelike can be used in various configurations. Used as a camera body most commercial lenses can be connected to the camera via existing lens adaptors. On the other hand the eyelike can be used as a back to most commercial 4' by 5' view cameras. This paper describes the eyelike camera concept with the essential system components. The article finishes with a description of the software, which is needed to bring the high quality of the camera to the user.

  18. Analyzer for gamma cameras diagnostic

    International Nuclear Information System (INIS)

    Oramas Polo, I.; Osorio Deliz, J. F.; Diaz Garcia, A.

    2013-01-01

    This research work was carried out to develop an analyzer for gamma cameras diagnostic. It is composed of an electronic system that includes hardware and software capabilities, and operates from the acquisition of the 4 head position signals of a gamma camera detector. The result is the spectrum of the energy delivered by nuclear radiation coming from the camera detector head. This system includes analog processing of position signals from the camera, digitization and the subsequent processing of the energy signal in a multichannel analyzer, sending data to a computer via a standard USB port and processing of data in a personal computer to obtain the final histogram. The circuits are composed of an analog processing board and a universal kit with micro controller and programmable gate array. (Author)

  19. New generation of meteorology cameras

    Science.gov (United States)

    Janout, Petr; Blažek, Martin; Páta, Petr

    2017-12-01

    A new generation of the WILLIAM (WIde-field aLL-sky Image Analyzing Monitoring system) camera includes new features such as monitoring of rain and storm clouds during the day observation. Development of the new generation of weather monitoring cameras responds to the demand for monitoring of sudden weather changes. However, new WILLIAM cameras are ready to process acquired image data immediately, release warning against sudden torrential rains, and send it to user's cell phone and email. Actual weather conditions are determined from image data, and results of image processing are complemented by data from sensors of temperature, humidity, and atmospheric pressure. In this paper, we present the architecture, image data processing algorithms of mentioned monitoring camera and spatially-variant model of imaging system aberrations based on Zernike polynomials.

  20. Contact lens surface by electron beam

    International Nuclear Information System (INIS)

    Shin, Jung Hyuck; Lee, Suk Ju; Hwang, Kwang Ha; Jeon Jin

    2011-01-01

    Contact lens materials needs good biocompatibility, high refractive index, high optical transparency, high water content etc. Surface treat method by using plasma and radiation can modify the physical and/or chemical properties of the contact lens surface. Radiation technology such as electron beam irradiation can apply to polymerization reaction and enhance the functionality of the polymer.The purpose of this study is to modify of contact lens surface by using Eb irradiation technology. Electron beam was irradiated to the contact lens surface which was synthesized thermal polymerization method and commercial contact lens to modify physical and chemical properties. Ft-IR, XP, UV-vis spectrophotometer, water content, oxygen trans-metastability were used to characterize the surface state, physicochemical, and optical property of the contact lens treated with Eb. The water content and oxygen transmissibility of the contact lens treated with Eb were increased due to increase in the hydrophilic group such as O-C=O and OH group on the contact lens surface which could be produced by possible reaction between carbon and oxygen during the Eb irradiation. All of the lenses showed the high optical transmittance above 90%. In this case of B/Es, TES, Ti contact lens, the optical transmittance decreased about 5% with increasing Eb dose in the wavelength of UV-B region. The contact lens modified by Eb irradiation could improve the physical properties of the contact lens such as water content and oxygen transmissibility

  1. Astronomy and the camera obscura

    Science.gov (United States)

    Feist, M.

    2000-02-01

    The camera obscura (from Latin meaning darkened chamber) is a simple optical device with a long history. In the form considered here, it can be traced back to 1550. It had its heyday during the Victorian era when it was to be found at the seaside as a tourist attraction or sideshow. It was also used as an artist's drawing aid and, in 1620, the famous astronomer-mathematician, Johannes Kepler used a small tent camera obscura to trace the scenery.

  2. Science, conservation, and camera traps

    Science.gov (United States)

    Nichols, James D.; Karanth, K. Ullas; O'Connel, Allan F.; O'Connell, Allan F.; Nichols, James D.; Karanth, K. Ullas

    2011-01-01

    Biologists commonly perceive camera traps as a new tool that enables them to enter the hitherto secret world of wild animals. Camera traps are being used in a wide range of studies dealing with animal ecology, behavior, and conservation. Our intention in this volume is not to simply present the various uses of camera traps, but to focus on their use in the conduct of science and conservation. In this chapter, we provide an overview of these two broad classes of endeavor and sketch the manner in which camera traps are likely to be able to contribute to them. Our main point here is that neither photographs of individual animals, nor detection history data, nor parameter estimates generated from detection histories are the ultimate objective of a camera trap study directed at either science or management. Instead, the ultimate objectives are best viewed as either gaining an understanding of how ecological systems work (science) or trying to make wise decisions that move systems from less desirable to more desirable states (conservation, management). Therefore, we briefly describe here basic approaches to science and management, emphasizing the role of field data and associated analyses in these processes. We provide examples of ways in which camera trap data can inform science and management.

  3. On the accuracy potential of focused plenoptic camera range determination in long distance operation

    Science.gov (United States)

    Sardemann, Hannes; Maas, Hans-Gerd

    2016-04-01

    Plenoptic cameras have found increasing interest in optical 3D measurement techniques in recent years. While their basic principle is 100 years old, the development in digital photography, micro-lens fabrication technology and computer hardware has boosted the development and lead to several commercially available ready-to-use cameras. Beyond their popular option of a posteriori image focusing or total focus image generation, their basic ability of generating 3D information from single camera imagery depicts a very beneficial option for certain applications. The paper will first present some fundamentals on the design and history of plenoptic cameras and will describe depth determination from plenoptic camera image data. It will then present an analysis of the depth determination accuracy potential of plenoptic cameras. While most research on plenoptic camera accuracy so far has focused on close range applications, we will focus on mid and long ranges of up to 100 m. This range is especially relevant, if plenoptic cameras are discussed as potential mono-sensorial range imaging devices in (semi-)autonomous cars or in mobile robotics. The results show the expected deterioration of depth measurement accuracy with depth. At depths of 30-100 m, which may be considered typical in autonomous driving, depth errors in the order of 3% (with peaks up to 10-13 m) were obtained from processing small point clusters on an imaged target. Outliers much higher than these values were observed in single point analysis, stressing the necessity of spatial or spatio-temporal filtering of the plenoptic camera depth measurements. Despite these obviously large errors, a plenoptic camera may nevertheless be considered a valid option for the application fields of real-time robotics like autonomous driving or unmanned aerial and underwater vehicles, where the accuracy requirements decrease with distance.

  4. Material Structure of a Graded Refractive Index Lens in Decapod Squid

    Science.gov (United States)

    Cai, Jing; Heiney, Paul; Sweeney, Alison

    2013-03-01

    Underwater vision with a camera-type eye that is simultaneously acute and sensitive requires a spherical lens with a graded distribution of refractive index. Squids have this type of lens, and our previous work has shown that its optical properties are likely achieved with radially variable densities of a single protein with multiple isoforms. Here we measure the spatial organization of this novel protein material in concentric layers of the lens and use these data to suggest possible mechanisms of self-assembly of the proteins into a graded refractive index structure. First, we performed small angle x-ray scattering (SAXS) to study how the protein is spatially organized. Then, molecular dynamic simulation allowed us to correlate structure to the possible dynamics of the system in different regions of the lens. The combination of simulation and SAXS data in this system revealed the likely protein-protein interactions, resulting material structure and its relationship to the observed and variable optical properties of this graded index system. We believe insights into the material properties of the squid lens system will inform the invention of self-assembling graded index devices.

  5. Optical Tests on a Curve Fresnel Lens as Secondary Optics for Solar Troughs

    Directory of Open Access Journals (Sweden)

    D. Fontani

    2017-01-01

    Full Text Available A curve Fresnel lens is developed as secondary concentrator for solar parabolic troughs to reduce the number of photovoltaic cells. Specific measurements and optical tests are used to evaluate the optical features of manufactured samples. The cylindrical Fresnel lens transforms the focal line, produced by the primary mirror, into a series of focal points. The execution of special laboratory tests on some secondary concentrator samples is discussed in detail, illustrating the methodologies tailored to the specific case. Focusing tests are performed, illuminating different areas of the lens with solar divergence light and acquiring images on the plane of the photocell using a CMOS camera. Concentration measurements are carried out to select the best performing samples of curve Fresnel lens. The insertion of the secondary optics within the concentrating photovoltaic (CPV trough doubles the solar concentration of the system. The mean concentration ratio is 1.73, 2.13, and 2.09 for the three tested lenses. The concentration ratio of the solar trough is 140 and approaches 300 after the introduction of the secondary lens.

  6. Looking beyond the perfect lens

    International Nuclear Information System (INIS)

    Wee, W H; Pendry, J B

    2010-01-01

    The holy grail of imaging is the ability to see through anything. From the conservation of energy, we can easily see that to see through a lossy material would require lenses with gain. The aim of this paper therefore is to propose a simple scheme by which we can construct a general perfect lens, with gain-one that can restore both the phases and amplitudes of near and far fields.

  7. "What Do You Think We Should Do?": Relationship and Reflexivity in Participant Observation.

    Science.gov (United States)

    Elliot, Michelle L

    2015-07-01

    This article uses three concepts as a framework by which to examine how the interrelational elements of ethnographic approaches to qualitative inquiry reflect dimensions of therapeutic engagement. Participant observation, reflexivity, and context are all widely and routinely included within research methods; however, they are less frequently attended to directly in their experiential capacity through the lens of the researcher, clinician turned investigator. A unique study design will be profiled to reflect the complicated juxtaposition between methods, questions, sample population, time, space, and identity. Studying occupational therapy students traveling abroad for a short-term immersion experience, this narrative study called on a necessary and attentive awareness of locality as the researcher traveled with the group. Conducting ethnographic research where the researcher's therapeutic skills aided and constrained relationships resulted in rich, guarded, and relevant insights that parallel the therapeutic use of self in occupational therapy practice.

  8. CONTACT LENS RELATED CORNEAL ULCER

    Directory of Open Access Journals (Sweden)

    AGARWAL P

    2010-01-01

    Full Text Available A corneal ulcer caused by infection is one of the major causes of blindness worldwide. One of the recent health concerns is the increasing incidence of corneal ulcers associated with contact lens user especially if the users fail to follow specific instruction in using their contact lenses. Risk factors associated with increased risk of contact lens related corneal ulcers are:overnight wear, long duration of continuous wear, lower socio-economic classes, smoking, dry eye and poor hygiene. The presenting symptoms of contact lens related corneal ulcers include eye discomfort, foreign body sensation and lacrimation. More serious symptoms are redness (especially circum-corneal injection, severe pain, photophobia, eye discharge and blurring of vision. The diagnosis is established by a thorough slit lamp microscopic examination with fluorescein staining and corneal scraping for Gram stain and culture of the infective organism. Delay in diagnosing and treatment can cause permanent blindness, therefore an early referral to ophthalmologist and commencing of antimicrobial therapy can prevent visual loss.

  9. The Lens Staring You in the Face

    Science.gov (United States)

    vachon, R. W.

    2012-12-01

    When you are embedded in the minutia of a science, you and your collaborators don't need to be convinced that there are benefits to investigating your precise science. You are intrinsically invested. In fact, we spend so much time around each other that we create our own language. So many acronyms that we come to take for granted and topic relevant words, like "fractionate", are not common parlance. This is the case with any specialization, but when it becomes second nature to communicate your work with these norms, transmission breaks down, people tune out, and some audiences become frustrated. Media can cushion this separation, but what do you do when you are the one in front of the camera, and clarity and impact of a concept rests on your shoulders? Just as writing a peer review paper is an acquired skill, so is communicating to the ones who pay many of our salaries, taxpayers. Over the past three years I have worked intimately with publishers, networks and university outreach programs to refine my approach to communicating scientific knowledge to particular audiences. The road has positioned me as interviewee, motivational speaker for science, technology, engineering and math (STEM) in middle and high schools, and educational video series host. Media has their own standards. Personality and enthusiasm may be just as important as the journal into which your findings were published. This presentation will emphasize the audience-adjustable tenants that have stood the test of time to result in effective video communication. Additionally, preparation for and execution of different roles in front of the lens will be discussed.Communicating concepts on video

  10. Sub-Camera Calibration of a Penta-Camera

    Science.gov (United States)

    Jacobsen, K.; Gerke, M.

    2016-03-01

    Penta cameras consisting of a nadir and four inclined cameras are becoming more and more popular, having the advantage of imaging also facades in built up areas from four directions. Such system cameras require a boresight calibration of the geometric relation of the cameras to each other, but also a calibration of the sub-cameras. Based on data sets of the ISPRS/EuroSDR benchmark for multi platform photogrammetry the inner orientation of the used IGI Penta DigiCAM has been analyzed. The required image coordinates of the blocks Dortmund and Zeche Zollern have been determined by Pix4Dmapper and have been independently adjusted and analyzed by program system BLUH. With 4.1 million image points in 314 images respectively 3.9 million image points in 248 images a dense matching was provided by Pix4Dmapper. With up to 19 respectively 29 images per object point the images are well connected, nevertheless the high number of images per object point are concentrated to the block centres while the inclined images outside the block centre are satisfying but not very strongly connected. This leads to very high values for the Student test (T-test) of the finally used additional parameters or in other words, additional parameters are highly significant. The estimated radial symmetric distortion of the nadir sub-camera corresponds to the laboratory calibration of IGI, but there are still radial symmetric distortions also for the inclined cameras with a size exceeding 5μm even if mentioned as negligible based on the laboratory calibration. Radial and tangential effects of the image corners are limited but still available. Remarkable angular affine systematic image errors can be seen especially in the block Zeche Zollern. Such deformations are unusual for digital matrix cameras, but it can be caused by the correlation between inner and exterior orientation if only parallel flight lines are used. With exception of the angular affinity the systematic image errors for corresponding

  11. SUB-CAMERA CALIBRATION OF A PENTA-CAMERA

    Directory of Open Access Journals (Sweden)

    K. Jacobsen

    2016-03-01

    Full Text Available Penta cameras consisting of a nadir and four inclined cameras are becoming more and more popular, having the advantage of imaging also facades in built up areas from four directions. Such system cameras require a boresight calibration of the geometric relation of the cameras to each other, but also a calibration of the sub-cameras. Based on data sets of the ISPRS/EuroSDR benchmark for multi platform photogrammetry the inner orientation of the used IGI Penta DigiCAM has been analyzed. The required image coordinates of the blocks Dortmund and Zeche Zollern have been determined by Pix4Dmapper and have been independently adjusted and analyzed by program system BLUH. With 4.1 million image points in 314 images respectively 3.9 million image points in 248 images a dense matching was provided by Pix4Dmapper. With up to 19 respectively 29 images per object point the images are well connected, nevertheless the high number of images per object point are concentrated to the block centres while the inclined images outside the block centre are satisfying but not very strongly connected. This leads to very high values for the Student test (T-test of the finally used additional parameters or in other words, additional parameters are highly significant. The estimated radial symmetric distortion of the nadir sub-camera corresponds to the laboratory calibration of IGI, but there are still radial symmetric distortions also for the inclined cameras with a size exceeding 5μm even if mentioned as negligible based on the laboratory calibration. Radial and tangential effects of the image corners are limited but still available. Remarkable angular affine systematic image errors can be seen especially in the block Zeche Zollern. Such deformations are unusual for digital matrix cameras, but it can be caused by the correlation between inner and exterior orientation if only parallel flight lines are used. With exception of the angular affinity the systematic image errors

  12. A lateral chromatic aberration correction system for ultrahigh-definition color video camera

    Science.gov (United States)

    Yamashita, Takayuki; Shimamoto, Hiroshi; Funatsu, Ryohei; Mitani, Kohji; Nojiri, Yuji

    2006-02-01

    We have developed color camera for an 8k x 4k-pixel ultrahigh-definition video system, which is called Super Hi- Vision, with a 5x zoom lens and a signal-processing system incorporating a function for real-time lateral chromatic aberration correction. The chromatic aberration of the lens degrades color image resolution. So in order to develop a compact zoom lens consistent with ultrahigh-resolution characteristics, we incorporated a real-time correction function in the signal-processing system. The signal-processing system has eight memory tables to store the correction data at eight focal length points on the blue and red channels. When the focal length data is inputted from the lens control units, the relevant correction data are interpolated from two of eights correction data tables. This system performs geometrical conversion on both channels using this correction data. This paper describes that the correction function can successfully reduce the lateral chromatic aberration, to an amount small enough to ensure the desired image resolution was achieved over the entire range of the lens in real time.

  13. Introducing free-function camera calibration model for central-projection and omni-directional lenses

    Science.gov (United States)

    Nekouei Shahraki, M.; Haala, N.

    2015-09-01

    To ensure making valid decisions with high accuracy in machine vision systems such as driver-assistant systems, a primary key factor is to have accurate measurements, which means that we need accurate camera calibration for various optical designs and a very fast approach to analyse the calibration data in real-time. Conventional methods have specific limitations such as limited accuracy, instability by using complex models, difficulties to model the local lens distortions and limitation in real-time calculations that altogether show the necessity to introduce new solutions. We introduce a new model for lens distortion modelling with high accuracies beyond conventional models while yet allowing real-time calculation. The concept is based on Free-Function modelling in a posterior calibration step using the initial distortion estimation and the corresponding residuals on the observations as input information. Free-Function model is the technique of numerically and locally modelling the lens distortion field by assuming unknown functions in our calibration model. This increases the model's flexibility to fit to different optical designs and be able to model the very local lens distortions. Using the Free-Function model one can observe great enhancements in accuracy (in comparison with classical models). Furthermore, by increasing the number of control points and improving their distribution the quality of lens modelling would be improved; a characteristic which is not present in the classical methods.

  14. Reflexive cartography a new perspective in mapping

    CERN Document Server

    Casti, Emanuela

    2015-01-01

    Reflexive Cartography addresses the adaptation of cartography, including its digital forms (GIS, WebGIS, PPGIS), to the changing needs of society, and outlines the experimental context aimed at mapping a topological space. Using rigorous scientific analysis based on statement consistency, relevance of the proposals, and model accessibility, it charts the transition from topographical maps created by state agencies to open mapping produced by citizens. Adopting semiotic theory to uncover the complex communicative mechanisms of maps and to investigate their ability to produce their own messages and new perspectives, Reflexive Cartography outlines a shift in our way of conceptualizing maps: from a plastic metaphor of reality, as they are generally considered, to solid tools that play the role of agents, assisting citizens as they think and plan their own living place and make sense of the current world. Applies a range of technologies to theoretical perspectives on mapping to innovatively map the world's geogr...

  15. The Reflexive Principle of Sociological Theorization

    Directory of Open Access Journals (Sweden)

    R T Ubaidullayeva

    2013-12-01

    Full Text Available The article attempts to describe the reflexive principle in theory-making, which integrates the basic modern methodological paradigms and lays the foundation for the development of sociology. On the basis of the theoretical ideas of P. Bourdieu, A. Giddens and P. Ricoeur the author defines the concept of social reflexion and reveals its peculiarities in sociology as compared to reflexion in philosophy. According to the author, the fulfillment of reflexive functions in sociology is connected with the task of analyzing the complex structure of the polysemantic object, considering the specific quality of the subjects and their various trends of development. The presence of the poles — objectivity-subjectivity, rationality-irrationality, consciousness-unconsciousness etc, requires a reproduction of the dichotomies engendering them in social life and development of cognitive methods for their study in sociology.

  16. Reflex sympathetic dystrophy syndrome in a child.

    Science.gov (United States)

    Badri, Talel; Ben Jennet, Salima; Fenniche, Samy; Benmously, Rym; Mokhtar, Inçaf; Hammami, Hatem

    2011-06-01

    Reflex sympathetic dystrophy syndrome (RSDS) is a painful condition that usually follows regional trauma. We report the case of a 13-year-old girl that was seen for a painful swelling of the right hand associated with palmar hyperhidrosis, which occurred after a trauma to the hand. Bone scan images showed early tissue abnormality, which was more significant on the right hand and wrist, as well as moderate bone uptake on the right side. Nonsteroidal anti-inflammatory drugs and alternating hot and cold baths led to a marked improvement. RSDS occurs following trauma or subsequent to various diseases or drug intake. This syndrome is related to impaired tissue microvasculature under the influence of abnormal sympathetic reflex hyperactivity. Bone scan is the diagnostic procedure of choice in RSDS, but it may be normal. Physiotherapy should be preferred in pediatric cases.

  17. Human investigations into the exercise pressor reflex

    DEFF Research Database (Denmark)

    Secher, Niels H; Amann, Markus

    2012-01-01

    . The importance of the exercise pressor reflex for tight cardiovascular regulation during dynamic exercise is supported by studies using pharmacological blockade of lower limb muscle afferent nerves. These experiments show attenuation of the increase in BP and cardiac output when exercise is performed......During exercise, neural input from skeletal muscles reflexly maintains or elevates blood pressure (BP) despite a maybe fivefold increase in vascular conductance. This exercise pressor reflex is illustrated by similar heart rate (HR) and BP responses to electrically induced and voluntary exercise...... with attenuated neural feedback. Additionally, there is no BP response to electrically induced exercise with paralysing epidural anaesthesia or when similar exercise is evoked in paraplegic patients. Furthermore, BP decreases when electrically induced exercise is carried out in tetraplegic patients. The lack...

  18. Life through a Lens: Risk, Surveillance and Subjectivity

    Directory of Open Access Journals (Sweden)

    Gavin Smith

    2016-03-01

    Full Text Available Drawing on findings from a two-year empirical study examining the culture of closed-circuit television (CCTV operation in the UK, this paper analyses how CCTV camera operators subjectively experience the visual media that they work to produce. It seeks to excavate some of the social meanings that these vicarious risk flâneurs ascribe to the telemediated events that they indirectly encounter, and how these ‘narratives of the street’ come to inscribe themselves on the subjectivities of the camera operators in a disciplinary manner. In so doing, the paper reveals the work of watching to be an ambiguous social practice, an activity that far exceeds its formal framing as a dispassionate and standardised procedure. As such, I contend that CCTV camera operators engage in two distinct modes of work – ‘surface’ and ‘deep’ – as they watch the screens and codify the spectacles that are mediated through the camera lens. The ‘surface’ work they enact is officially acknowledged and concerns their focusing attention on the screens to identify harmful behaviours, to capture evidence and to share information with other collaborators in the security network. This mode of work is principally performed for professional imperatives and economic returns. In contrast, the ‘deep’ work rituals they execute are informal in scope and therapeutic in purpose. Such individualised practices are an unseen and unrecognised work relation that mitigates the negative effects of CCTV viewing. They are operationalised through diverse behavioural repertoires which function to insulate the self from its exposure to mediated traumas, and from the contradiction of mobilising ‘(inaction at a distance’. Overall, the paper accentuates the messy realities that hinge on the practice of urban surveillance, showing these realities to be meditated by the vagaries of subjective experience and social relations.

  19. Ontogenetic development of vestibular reflexes in amphibians

    Directory of Open Access Journals (Sweden)

    Hans Straka

    2016-11-01

    Full Text Available Vestibulo-ocular reflexes ensure gaze stability during locomotion and passively induced head/body movements. In precocial vertebrates such as amphibians, vestibular reflexes are required very early at the onset of locomotor activity. While the formation of inner ears and the assembly of sensory-motor pathways is largely completed soon after hatching, angular and translational/tilt vestibulo-ocular reflexes (VOR display differential functional onsets and mature with different time courses. Otolith-derived eye movements appear immediately after hatching, whereas the appearance and progressive amelioration of semicircular canal-evoked eye movements is delayed and dependent on the acquisition of sufficiently large semicircular canal diameters. Moreover, semicircular canal functionality is also required to tune the initially omnidirectional otolith-derived VOR. The tuning is due to a reinforcement of those vestibulo-ocular connections that are co-activated by semicircular canal and otolith inputs during natural head/body motion. This suggests that molecular mechanisms initially guide the basic ontogenetic wiring, whereas semicircular canal-dependent activity is required to establish the spatio-temporal specificity of the reflex. While a robust VOR is activated during passive head/body movements, locomotor efference copies provide the major source for compensatory eye movements during tail- and limb-based swimming of larval and adult frogs. The integration of active/passive motion-related signals for gaze stabilization occurs in central vestibular neurons that are arranged as segmentally iterated functional groups along rhombomere 1-8. However, at variance with the topographic maps of most other sensory systems, the sensory-motor transformation of motion-related signals occurs in segmentally specific neuronal groups defined by the extraocular motor output targets.

  20. Entrepreneurship Teaching Conducted as Strategic Reflexive Conversation

    DEFF Research Database (Denmark)

    Kristiansson, Michael

    and be applied to entrepreneurship-centred instructional activities. The concept of strategic reflexive conversation must be regarded as relevant and are of clear pertinence to theoretical and practical entrepreneurship to entrepreneurship-oriented teaching and learning activities....... advantageously, and on a pilot basis, be applied to entrepreneurship in practical environments and within the framework of entrepreneurship-centred teaching. The present theoretical investigation is solely of an introductory nature and steps are considered that can lead to the planning of additional exploratory...

  1. Otolith and canal reflexes in human standing

    Science.gov (United States)

    Cathers, Ian; Day, Brian L; Fitzpatrick, Richard C

    2005-01-01

    We used galvanic vestibular stimulation (GVS) to identify human balance reflexes of the semicircular canals and otolith organs. The experiment used a model of vestibular signals arising from GVS modulation of the net signal from vestibular afferents. With the head upright, the model predicts that the GVS-evoked canal signal indicates lateral head rotation while the otolith signal indicates lateral tilt or acceleration. Both signify body sway transverse to the head. With the head bent forward, the model predicts that the canal signal indicates body spin about a vertical axis but the otolith signal still signifies lateral body motion. Thus, we compared electromyograms (EMG) in the leg muscles and body sway evoked by GVS when subjects stood with the head upright or bent forward. With the head upright, GVS evoked a large sway in the direction of the anodal electrode. This response was abolished with the head bent forward leaving only small, oppositely directed, transient responses at the start and end of the stimulus. With the head upright, GVS evoked short-latency (60–70 ms), followed by medium-latency (120 ms) EMG responses, of opposite polarity. Bending the head forward abolished the medium-latency but preserved the short-latency response. This is compatible with GVS evoking separate otolithic and canal reflexes, indicating that balance is controlled by independent canal and otolith reflexes, probably through different pathways. We propose that the short-latency reflex and small transient sway are driven by the otolith organs and the medium-latency response and the large sway are driven by the semicircular canals. PMID:15618274

  2. Evolutionary problems in non-reflexive spaces

    Czech Academy of Sciences Publication Activity Database

    Kružík, Martin; Zimmer, J.

    2010-01-01

    Roč. 16, č. 1 (2010), s. 1-22 ISSN 1262-3377 R&D Projects: GA AV ČR IAA1075402 Institutional research plan: CEZ:AV0Z10750506 Keywords : concentrations * energetic solution * energies with linear growth * oscillations * relaxation Subject RIV: BA - General Mathematics Impact factor: 1.084, year: 2009 http://library.utia.cas.cz/separaty/2008/MTR/kruzik-evolutionary problems in non-reflexive spaces.pdf

  3. Technical assessment of Navitar Zoom 6000 optic and Sony HDC-X310 camera for MEMS presentations and training.

    Energy Technology Data Exchange (ETDEWEB)

    Diegert, Carl F.

    2006-02-01

    This report evaluates a newly-available, high-definition, video camera coupled with a zoom optical system for microscopic imaging of micro-electro-mechanical systems. We did this work to support configuration of three document-camera-like stations as part of an installation in a new Microsystems building at Sandia National Laboratories. The video display walls to be installed as part of these three presentation and training stations are of extraordinary resolution and quality. The new availability of a reasonably-priced, cinema-quality, high-definition video camera offers the prospect of filling these displays with full-motion imaging of Sandia's microscopic products at a quality substantially beyond the quality of typical video microscopes. Simple and robust operation of the microscope stations will allow the extraordinary-quality imaging to contribute to Sandia's day-to-day research and training operations. This report illustrates the disappointing image quality from a camera/lens system comprised of a Sony HDC-X310 high-definition video camera coupled to a Navitar Zoom 6000 lens. We determined that this Sony camera is capable of substantially more image quality than the Navitar optic can deliver. We identified an optical doubler lens from Navitar as the component of their optical system that accounts for a substantial part of the image quality problem. While work continues to incrementally improve performance of the Navitar system, we are also evaluating optical systems from other vendors to couple to this Sony camera.

  4. IMPLEMENTATION OF ZOOM-DEPENDENT CAMERA CALIBRATION IN CLOSE-RANGE PHOTOGRAMMETRY

    Directory of Open Access Journals (Sweden)

    C. S. Fraser

    2012-07-01

    Full Text Available The application of consumer-grade cameras for photogrammetric measurement has traditionally been subject to the requirement that imagery is recorded at fixed zoom and focus settings. The camera is then metrically calibrated, usually via self-calibration, for the lens setting employed. This requirement arises since camera parameters, and especially principal distance and lens distortion coefficients, vary significantly with zoom/focus setting. A recently developed process, titled zoom-dependent (Z-D calibration, removes the necessity for the zoom setting to be fixed during the image capture process. Implementation of Z-D calibration requires that the camera be pre-calibrated at four or more focal settings within the zoom range, nominally at shortest and longest focal lengths, and at two mid-zoom settings. This requirement, coupled with issues of data management in carrying different focal settings for potentially every image within a bundle adjustment, has largely accounted for the reason that Z-D calibration has not previously been implemented within COTS software for close-range photogrammetry. The objective of this paper is to describe the practical implementation of Z-D calibration within software, along with its associated workflow, and to discuss issues that impact upon the accuracy, reliability and appropriateness of the technique. Experimental testing is used to highlight the merits and shortcomings of ZD calibration.

  5. The fly's eye camera system

    Science.gov (United States)

    Mészáros, L.; Pál, A.; Csépány, G.; Jaskó, A.; Vida, K.; Oláh, K.; Mezö, G.

    2014-12-01

    We introduce the Fly's Eye Camera System, an all-sky monitoring device intended to perform time domain astronomy. This camera system design will provide complementary data sets for other synoptic sky surveys such as LSST or Pan-STARRS. The effective field of view is obtained by 19 cameras arranged in a spherical mosaic form. These individual cameras of the device stand on a hexapod mount that is fully capable of achieving sidereal tracking for the subsequent exposures. This platform has many advantages. First of all it requires only one type of moving component and does not include unique parts. Hence this design not only eliminates problems implied by unique elements, but the redundancy of the hexapod allows smooth operations even if one or two of the legs are stuck. In addition, it can calibrate itself by observed stars independently from both the geographical location (including northen and southern hemisphere) and the polar alignment of the full mount. All mechanical elements and electronics are designed within the confines of our institute Konkoly Observatory. Currently, our instrument is in testing phase with an operating hexapod and reduced number of cameras.

  6. Basic Gravitational Reflexes in the Larval Frog

    Science.gov (United States)

    Cochran, Stephen L.

    1996-01-01

    This investigation was designed to determine how a primitive vertebrate, the bullfrog tadpole, is able to sense and process gravitational stimuli. Because of the phylogenetic similarities of the vestibular systems in all vertebrates, the understanding of the gravitational reflexes in this relatively simple vertebrate should elucidate a skeletal framework on a elementary level, upon which the more elaborate reflexes of higher vertebrates may be constructed. The purpose of this study was to understand how the nervous system of the larval amphibian processes gravitational information. This study involved predominantly electrophysiological investigations of the isolated, alert (forebrain removed) bullfrog tadpole head. The focus of these experiments is threefold: (1) to understand from whole extraocular nerve recordings the signals sent to the eye following static gravitational tilt of the head; (2) to localize neuronal centers responsible for generating these signals through reversible pharmacological ablation of these centers; and (3) to record intracellularly from neurons within these centers in order to determine the single neuron's role in the overall processing of the center. This study has provided information on the mechanisms by which a primitive vertebrate processes gravitational reflexes.

  7. Trend of digital camera and interchangeable zoom lenses with high ratio based on patent application over the past 10 years

    Science.gov (United States)

    Sensui, Takayuki

    2012-10-01

    Although digitalization has tripled consumer-class camera market scale, extreme reductions in prices of fixed-lens cameras has reduced profitability. As a result, a number of manufacturers have entered the market of the System DSC i.e. digital still camera with interchangeable lens, where large profit margins are possible, and many high ratio zoom lenses with image stabilization functions have been released. Quiet actuators are another indispensable component. Design with which there is little degradation in performance due to all types of errors is preferred for good balance in terms of size, lens performance, and the rate of quality to sub-standard products. Decentering, such as that caused by tilting, sensitivity of moving groups is especially important. In addition, image stabilization mechanisms actively shift lens groups. Development of high ratio zoom lenses with vibration reduction mechanism is confronted by the challenge of reduced performance due to decentering, making control over decentering sensitivity between lens groups everything. While there are a number of ways to align lenses (axial alignment), shock resistance and ability to stand up to environmental conditions must also be considered. Naturally, it is very difficult, if not impossible, to make lenses smaller and achieve a low decentering sensitivity at the same time. 4-group zoom construction is beneficial in making lenses smaller, but decentering sensitivity is greater. 5-group zoom configuration makes smaller lenses more difficult, but it enables lower decentering sensitivities. At Nikon, the most advantageous construction is selected for each lens based on specifications. The AF-S DX NIKKOR 18-200mm f/3.5-5.6G ED VR II and AF-S NIKKOR 28-300mm f/3.5-5.6G ED VR are excellent examples of this.

  8. Multiple-image oscilloscope camera

    International Nuclear Information System (INIS)

    Yasillo, N.J.

    1978-01-01

    An optical device for placing automatically a plurality of images at selected locations on one film comprises a stepping motor coupled to a rotating mirror and lens. A mechanical connection from the mirror controls an electronic logical system to allow rotation of the mirror to place a focused image at tge desired preselected location. The device is of especial utility when used to place four images on a single film to record oscilloscope views obtained in gamma radiography

  9. Dark Energy Camera for Blanco

    Energy Technology Data Exchange (ETDEWEB)

    Binder, Gary A.; /Caltech /SLAC

    2010-08-25

    In order to make accurate measurements of dark energy, a system is needed to monitor the focus and alignment of the Dark Energy Camera (DECam) to be located on the Blanco 4m Telescope for the upcoming Dark Energy Survey. One new approach under development is to fit out-of-focus star images to a point spread function from which information about the focus and tilt of the camera can be obtained. As a first test of a new algorithm using this idea, simulated star images produced from a model of DECam in the optics software Zemax were fitted. Then, real images from the Mosaic II imager currently installed on the Blanco telescope were used to investigate the algorithm's capabilities. A number of problems with the algorithm were found, and more work is needed to understand its limitations and improve its capabilities so it can reliably predict camera alignment and focus.

  10. High-speed two-camera imaging pyrometer for mapping fireball temperatures.

    Science.gov (United States)

    Densmore, John M; Homan, Barrie E; Biss, Matthew M; McNesby, Kevin L

    2011-11-20

    A high-speed imaging pyrometer was developed to investigate the behavior of flames and explosive events. The instrument consists of two monochrome high-speed Phantom v7.3 m cameras made by Vision Research Inc. arranged so that one lens assembly collects light for both cameras. The cameras are filtered at 700 or 900 nm with a 10 nm bandpass. The high irradiance produced by blackbody emission combined with variable shutter time and f-stop produces properly exposed images. The wavelengths were chosen with the expected temperatures in mind, and also to avoid any molecular or atomic gas phase emission. Temperatures measured using this pyrometer of exploded TNT charges are presented.

  11. New light field camera based on physical based rendering tracing

    Science.gov (United States)

    Chung, Ming-Han; Chang, Shan-Ching; Lee, Chih-Kung

    2014-03-01

    Even though light field technology was first invented more than 50 years ago, it did not gain popularity due to the limitation imposed by the computation technology. With the rapid advancement of computer technology over the last decade, the limitation has been uplifted and the light field technology quickly returns to the spotlight of the research stage. In this paper, PBRT (Physical Based Rendering Tracing) was introduced to overcome the limitation of using traditional optical simulation approach to study the light field camera technology. More specifically, traditional optical simulation approach can only present light energy distribution but typically lack the capability to present the pictures in realistic scenes. By using PBRT, which was developed to create virtual scenes, 4D light field information was obtained to conduct initial data analysis and calculation. This PBRT approach was also used to explore the light field data calculation potential in creating realistic photos. Furthermore, we integrated the optical experimental measurement results with PBRT in order to place the real measurement results into the virtually created scenes. In other words, our approach provided us with a way to establish a link of virtual scene with the real measurement results. Several images developed based on the above-mentioned approaches were analyzed and discussed to verify the pros and cons of the newly developed PBRT based light field camera technology. It will be shown that this newly developed light field camera approach can circumvent the loss of spatial resolution associated with adopting a micro-lens array in front of the image sensors. Detailed operational constraint, performance metrics, computation resources needed, etc. associated with this newly developed light field camera technique were presented in detail.

  12. Primary intraocular lens implantation for penetrating lens trauma in Africa.

    Science.gov (United States)

    Bowman, R J; Yorston, D; Wood, M; Gilbert, C; Foster, A

    1998-09-01

    This study aimed to audit the surgical strategy of primary posterior chamber intraocular lens implantation for cases of recent penetrating trauma involving the lens in an African population. Retrospective, noncomparative case series. Seventy-two cases are reported, including all patients who underwent primary intraocular lens implantation for traumatic cataract extraction performed within 1 month of injury between 1988 and 1996. Demographic characteristics and follow-up attendance rates are analyzed. Surgical technique and the occurrence of intraoperative and postoperative complications are reported. Visual outcomes are reported with detailed analysis for cases of poor visual outcome. Mean age was 14.3 years (standard deviation = 11.1), 57 (79%) were male and 15 (21%) were female (chi-square = 23.66, P capsule had been breached by the trauma in 27 (38%) cases, and 15 of these required anterior vitrectomy. Capsular fixation of the implant was achieved in 49% of patients, the remainder having sulcus fixation. Intraoperative rupture of the posterior capsule occurred in four cases. The only common postoperative complication was acute fibrinous anterior uveitis, which occurred in 29 (40%) patients, and 32% of patients followed up for at least 6 months required secondary posterior capsulotomy. This was more common in younger patients (chi-square = 4.2, P < 0.05). Corrected postoperative visual acuities were available for 51 patients, of which 71% achieved 20/60 or better visual acuity. Patients 6 years of age or younger were less likely to achieve 20/60 (chi-square = 6.61, P = 0.01). This surgical strategy has proved successful, producing good visual results and causing no sight-threatening complications. Primary posterior capsulotomy may be appropriate for younger patients.

  13. EDICAM (Event Detection Intelligent Camera)

    Energy Technology Data Exchange (ETDEWEB)

    Zoletnik, S. [Wigner RCP RMI, EURATOM Association, Budapest (Hungary); Szabolics, T., E-mail: szabolics.tamas@wigner.mta.hu [Wigner RCP RMI, EURATOM Association, Budapest (Hungary); Kocsis, G.; Szepesi, T.; Dunai, D. [Wigner RCP RMI, EURATOM Association, Budapest (Hungary)

    2013-10-15

    Highlights: ► We present EDICAM's hardware modules. ► We present EDICAM's main design concepts. ► This paper will describe EDICAM firmware architecture. ► Operation principles description. ► Further developments. -- Abstract: A new type of fast framing camera has been developed for fusion applications by the Wigner Research Centre for Physics during the last few years. A new concept was designed for intelligent event driven imaging which is capable of focusing image readout to Regions of Interests (ROIs) where and when predefined events occur. At present these events mean intensity changes and external triggers but in the future more sophisticated methods might also be defined. The camera provides 444 Hz frame rate at full resolution of 1280 × 1024 pixels, but monitoring of smaller ROIs can be done in the 1–116 kHz range even during exposure of the full image. Keeping space limitations and the harsh environment in mind the camera is divided into a small Sensor Module and a processing card interconnected by a fast 10 Gbit optical link. This camera hardware has been used for passive monitoring of the plasma in different devices for example at ASDEX Upgrade and COMPASS with the first version of its firmware. The new firmware and software package is now available and ready for testing the new event processing features. This paper will present the operation principle and features of the Event Detection Intelligent Camera (EDICAM). The device is intended to be the central element in the 10-camera monitoring system of the Wendelstein 7-X stellarator.

  14. Polyfunctionality and distribution of reflexive verbs in Latvian

    Directory of Open Access Journals (Sweden)

    Andra Kalnača

    2017-02-01

    Full Text Available The aim of the current paper is to analyze Latvian reflexive verbs from the point of view of their polyfunctionality and distributon.The polysemy of the reflexive verbs is not usually disucussed in the connection with its distribution pattern in the sentence either. This can be partly explianed by the fact that the reflexive verb can have some non-standard language meanings, which following the established practice of the traditional grammars and sometimes even dictionaries,  were not depicted in the language system description either. So the current paper is an attempt to analyze the polyfunctionality of reflexive verbs in connection with their semantic and syntactic functions, without judging the language use from the normative point of view.The classification of Latvian reflexive verbs is based on the relationship between semantic roles and syntactic structure according to the principles devised by Palmer (1994 and Saeed (1997.One and the same reflexive verb may have different lexical meanings with a different distribution for each of the meanings. One and the same verb can belong to different subclasses of the subject and object (or impersonal verbs.Some reflexive verbs have evaluative or aspectual (iterative meanings. The evaluative meanings usually are manifested by a positive or negative assessment of the event (the context can be enhanced by the adverbs good or bad and the consequences while the aspectual meaning is manifested by the intensity of the action, that is – iterativity.The study confirms the assumption that reflexive verbs are independent lexemes as opposed to non-reflexive verb forms. Each reflexive verb has its distinct semantic system and distribution which is different from polysemy of non-reflexive verbs and their distribution. The system of reflexive verbs in Latvian is open where new meanings and even new reflexive verbs arise particularly in colloquial use.

  15. Streak cameras and their applications

    International Nuclear Information System (INIS)

    Bernet, J.M.; Imhoff, C.

    1987-01-01

    Over the last several years, development of various measurement techniques in the nanosecond and pico-second range has led to increased reliance on streak cameras. This paper will present the main electronic and optoelectronic performances of the Thomson-CSF TSN 506 cameras and their associated devices used to build an automatic image acquisition and processing system (NORMA). A brief survey of the diversity and the spread of the use of high speed electronic cinematography will be illustrated by a few typical applications [fr

  16. The swallowing reflex and its significance as an airway defensive reflex

    Directory of Open Access Journals (Sweden)

    Takashi eNishino

    2013-01-01

    Full Text Available Swallowing function, in humans, is very complex. Swallowing plays, not only an important role in food digestion, but also a major role in preventing the entrance of food and/or other materials into the lower respiratory tract. To achieve this, precise coordination is necessary between breathing and swallowing since the pharynx serves as a common pathway for both respiration and digestion. The swallowing reflex consists of afferent pathways, central integration, and efferent pathways. Any defect or disorder along reflex arc can cause a potential delay or impairment in swallow function. The swallowing reflex can be modulated not only by pathological factors but also by physiological factors. Among these, timing of swallows in relation to the phase of respiration may be the most important factor that determines the occurrence of pulmonary aspiration, since phases of inspiration and the expiration-inspiration transition are the most vulnerable for pulmonary aspiration.

  17. Development of an Algorithm for Heart Rate Measurement Using a Mobile Phone Camera

    Directory of Open Access Journals (Sweden)

    D. A. Laure

    2014-01-01

    Full Text Available Nowadays there exist many different ways to measure a person’s heart rate. One of them assumes the usage of a mobile phone built-in camera. This method is easy to use and does not require any additional skills or special devices for heart rate measurement. It requires only a mobile cellphone with a built-in camera and a flash. The main idea of the method is to detect changes in finger skin color that occur due to blood pulsation. The measurement process is simple: the user covers the camera lens with a finger and the application on the mobile phone starts catching and analyzing frames from the camera. Heart rate can be calculated by analyzing average red component values of frames taken by the mobile cellphone camera that contain images of an area of the skin.In this paper the authors review the existing algorithms for heart rate measurement with the help of a mobile phone camera and propose their own algorithm which is more efficient than the reviewed algorithms.

  18. Error modeling and analysis of star cameras for a class of 1U spacecraft

    Science.gov (United States)

    Fowler, David M.

    As spacecraft today become increasingly smaller, the demand for smaller components and sensors rises as well. The smartphone, a cutting edge consumer technology, has impressive collections of both sensors and processing capabilities and may have the potential to fill this demand in the spacecraft market. If the technologies of a smartphone can be used in space, the cost of building miniature satellites would drop significantly and give a boost to the aerospace and scientific communities. Concentrating on the problem of spacecraft orientation, this study sets ground to determine the capabilities of a smartphone camera when acting as a star camera. Orientations determined from star images taken from a smartphone camera are compared to those of higher quality cameras in order to determine the associated accuracies. The results of the study reveal the abilities of low-cost off-the-shelf imagers in space and give a starting point for future research in the field. The study began with a complete geometric calibration of each analyzed imager such that all comparisons start from the same base. After the cameras were calibrated, image processing techniques were introduced to correct for atmospheric, lens, and image sensor effects. Orientations for each test image are calculated through methods of identifying the stars exposed on each image. Analyses of these orientations allow the overall errors of each camera to be defined and provide insight into the abilities of low-cost imagers.

  19. Multiple-aperture optical design for micro-level cameras using 3D-printing method

    Science.gov (United States)

    Peng, Wei-Jei; Hsu, Wei-Yao; Cheng, Yuan-Chieh; Lin, Wen-Lung; Yu, Zong-Ru; Chou, Hsiao-Yu; Chen, Fong-Zhi; Fu, Chien-Chung; Wu, Chong-Syuan; Huang, Chao-Tsung

    2018-02-01

    The design of the ultra miniaturized camera using 3D-printing technology directly printed on to the complementary metal-oxide semiconductor (CMOS) imaging sensor is presented in this paper. The 3D printed micro-optics is manufactured using the femtosecond two-photon direct laser writing, and the figure error which could achieve submicron accuracy is suitable for the optical system. Because the size of the micro-level camera is approximately several hundreds of micrometers, the resolution is reduced much and highly limited by the Nyquist frequency of the pixel pitch. For improving the reduced resolution, one single-lens can be replaced by multiple-aperture lenses with dissimilar field of view (FOV), and then stitching sub-images with different FOV can achieve a high resolution within the central region of the image. The reason is that the angular resolution of the lens with smaller FOV is higher than that with larger FOV, and then the angular resolution of the central area can be several times than that of the outer area after stitching. For the same image circle, the image quality of the central area of the multi-lens system is significantly superior to that of a single-lens. The foveated image using stitching FOV breaks the limitation of the resolution for the ultra miniaturized imaging system, and then it can be applied such as biomedical endoscopy, optical sensing, and machine vision, et al. In this study, the ultra miniaturized camera with multi-aperture optics is designed and simulated for the optimum optical performance.

  20. Research on one manual zoom liquid lens

    Science.gov (United States)

    Zhao, Cunhua; Shi, Yongpeng; Li, Wenjiao; Li, Congcong

    2011-11-01

    In liquid zoom lens, the accurate fixed-focus location needs the accurate calculation of focal length. That is to say, the accurate calculation of surface curvature must be obtained. Therefore, the research of their relation in liquid zoom lens becomes extremely important which has a directly theoretical instruction for the design of liquid zoom lenses. In our paper, the relation is studied. A manual liquid lens is reported which has upper and nether components with specificaton Φ12×5mm. The zoom lens is obtained by the upper component circumvolving down into the nether components.

  1. Numerical analyses of planer plasmonic focusing lens

    Science.gov (United States)

    Chou, Yen-Yu; Lee, Yeeu-Chang

    2018-03-01

    The use of polystyrene (PS) sphere lithography has been widely applied in the fabrication of micron and nano structures, due to their low cost and ease of fabrication in large scale applications. This study evaluated the feasibility of plasmonic lens base on metal thin films with nanohole structures fabricated by using PS sphere lithography through three-dimensional (3D) finite difference time domain (FDTD) method. We calculated the intensity profile of lens with various wavelength of incident light, lens size, cutting positions, diameters of nanohole, and periods of nanohole to investigate the geometric parameters influence on the focusing properties of the plasmonic lens.

  2. Only Image Based for the 3d Metric Survey of Gothic Structures by Using Frame Cameras and Panoramic Cameras

    Science.gov (United States)

    Pérez Ramos, A.; Robleda Prieto, G.

    2016-06-01

    Indoor Gothic apse provides a complex environment for virtualization using imaging techniques due to its light conditions and architecture. Light entering throw large windows in combination with the apse shape makes difficult to find proper conditions to photo capture for reconstruction purposes. Thus, documentation techniques based on images are usually replaced by scanning techniques inside churches. Nevertheless, the need to use Terrestrial Laser Scanning (TLS) for indoor virtualization means a significant increase in the final surveying cost. So, in most cases, scanning techniques are used to generate dense point clouds. However, many Terrestrial Laser Scanner (TLS) internal cameras are not able to provide colour images or cannot reach the image quality that can be obtained using an external camera. Therefore, external quality images are often used to build high resolution textures of these models. This paper aims to solve the problem posted by virtualizing indoor Gothic churches, making that task more affordable using exclusively techniques base on images. It reviews a previous proposed methodology using a DSRL camera with 18-135 lens commonly used for close range photogrammetry and add another one using a HDR 360° camera with four lenses that makes the task easier and faster in comparison with the previous one. Fieldwork and office-work are simplified. The proposed methodology provides photographs in such a good conditions for building point clouds and textured meshes. Furthermore, the same imaging resources can be used to generate more deliverables without extra time consuming in the field, for instance, immersive virtual tours. In order to verify the usefulness of the method, it has been decided to apply it to the apse since it is considered one of the most complex elements of Gothic churches and it could be extended to the whole building.

  3. Exchange of tears under a contact lens is driven by distortions of the contact lens.

    Science.gov (United States)

    Maki, Kara L; Ross, David S

    2014-12-01

    We studied the flow of the post-lens tear film under a soft contact lens to understand how the design parameters of contact lenses can affect ocular health. When a soft contact lens is inserted, the blinking eyelid causes the lens to stretch in order to conform to the shape of the eye. The deformed contact lens acts to assume its un-deformed shape and thus generates a suction pressure in the post-lens tear film. In consequence, the post-lens tear fluid moves; it responds to the suction pressure. The suction pressure may draw in fresh fluid from the edge of the lens, or it may eject fluid there, as the lens reassumes its un-deformed shape. In this article, we develop a mathematical model of the flow of the post-lens tear fluid in response to the mechanical suction pressure of a deformed contact lens. We predict the amount of exchange of fluid exchange under a contact lens and we explore the influence of the eye's shape on the rate of exchange of fluid. © The Author 2014. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved. For permissions please email: journals.permissions@oup.com.

  4. The Mars Hand Lens Imager (MAHLI) aboard the Mars rover, Curiosity

    Science.gov (United States)

    Edgett, K. S.; Ravine, M. A.; Caplinger, M. A.; Ghaemi, F. T.; Schaffner, J. A.; Malin, M. C.; Baker, J. M.; Dibiase, D. R.; Laramee, J.; Maki, J. N.; Willson, R. G.; Bell, J. F., III; Cameron, J. F.; Dietrich, W. E.; Edwards, L. J.; Hallet, B.; Herkenhoff, K. E.; Heydari, E.; Kah, L. C.; Lemmon, M. T.; Minitti, M. E.; Olson, T. S.; Parker, T. J.; Rowland, S. K.; Schieber, J.; Sullivan, R. J.; Sumner, D. Y.; Thomas, P. C.; Yingst, R. A.

    2009-08-01

    The Mars Science Laboratory (MSL) rover, Curiosity, is expected to land on Mars in 2012. The Mars Hand Lens Imager (MAHLI) will be used to document martian rocks and regolith with a 2-megapixel RGB color CCD camera with a focusable macro lens mounted on an instrument-bearing turret on the end of Curiosity's robotic arm. The flight MAHLI can focus on targets at working distances of 20.4 mm to infinity. At 20.4 mm, images have a pixel scale of 13.9 μm/pixel. The pixel scale at 66 mm working distance is about the same (31 μm/pixel) as that of the Mars Exploration Rover (MER) Microscopic Imager (MI). MAHLI camera head placement is dependent on the capabilities of the MSL robotic arm, the design for which presently has a placement uncertainty of ~20 mm in 3 dimensions; hence, acquisition of images at the minimum working distance may be challenging. The MAHLI consists of 3 parts: a camera head, a Digital Electronics Assembly (DEA), and a calibration target. The camera head and DEA are connected by a JPL-provided cable which transmits data, commands, and power. JPL is also providing a contact sensor. The camera head will be mounted on the rover's robotic arm turret, the DEA will be inside the rover body, and the calibration target will be mounted on the robotic arm azimuth motor housing. Camera Head. MAHLI uses a Kodak KAI-2020CM interline transfer CCD (1600 x 1200 active 7.4 μm square pixels with RGB filtered microlenses arranged in a Bayer pattern). The optics consist of a group of 6 fixed lens elements, a movable group of 3 elements, and a fixed sapphire window front element. Undesired near-infrared radiation is blocked using a coating deposited on the inside surface of the sapphire window. The lens is protected by a dust cover with a Lexan window through which imaging can be ac-complished if necessary, and targets can be illuminated by sunlight or two banks of two white light LEDs. Two 365 nm UV LEDs are included to search for fluores-cent materials at night. DEA

  5. Automatic Level Control for Video Cameras towards HDR Techniques

    Directory of Open Access Journals (Sweden)

    de With PeterHN

    2010-01-01

    Full Text Available We give a comprehensive overview of the complete exposure processing chain for video cameras. For each step of the automatic exposure algorithm we discuss some classical solutions and propose their improvements or give new alternatives. We start by explaining exposure metering methods, describing types of signals that are used as the scene content descriptors as well as means to utilize these descriptors. We also discuss different exposure control types used for the control of lens, integration time of the sensor, and gain control, such as a PID control, precalculated control based on the camera response function, and propose a new recursive control type that matches the underlying image formation model. Then, a description of commonly used serial control strategy for lens, sensor exposure time, and gain is presented, followed by a proposal of a new parallel control solution that integrates well with tone mapping and enhancement part of the image pipeline. Parallel control strategy enables faster and smoother control and facilitates optimally filling the dynamic range of the sensor to improve the SNR and an image contrast, while avoiding signal clipping. This is archived by the proposed special control modes used for better display and correct exposure of both low-dynamic range and high-dynamic range images. To overcome the inherited problems of limited dynamic range of capturing devices we discuss a paradigm of multiple exposure techniques. Using these techniques we can enable a correct rendering of difficult class of high-dynamic range input scenes. However, multiple exposure techniques bring several challenges, especially in the presence of motion and artificial light sources such as fluorescent lights. In particular, false colors and light-flickering problems are described. After briefly discussing some known possible solutions for the motion problem, we focus on solving the fluorescence-light problem. Thereby, we propose an algorithm for

  6. The Camera Comes to Court.

    Science.gov (United States)

    Floren, Leola

    After the Lindbergh kidnapping trial in 1935, the American Bar Association sought to eliminate electronic equipment from courtroom proceedings. Eventually, all but two states adopted regulations applying that ban to some extent, and a 1965 Supreme Court decision encouraged the banning of television cameras at trials as well. Currently, some states…

  7. High-speed holographic camera

    International Nuclear Information System (INIS)

    Novaro, Marc

    The high-speed holographic camera is a disgnostic instrument using holography as an information storing support. It allows us to take 10 holograms, of an object, with exposures times of 1,5ns, separated in time by 1 or 2ns. In order to get these results easily, no mobile part is used in the set-up [fr

  8. Camera Movement in Narrative Cinema

    DEFF Research Database (Denmark)

    Nielsen, Jakob Isak

    2007-01-01

    Just like art historians have focused on e.g. composition or lighting, this dissertation takes a single stylistic parameter as its object of study: camera movement. Within film studies this localized avenue of middle-level research has become increasingly viable under the aegis of a perspective k...

  9. Toy Cameras and Color Photographs.

    Science.gov (United States)

    Speight, Jerry

    1979-01-01

    The technique of using toy cameras for both black-and-white and color photography in the art class is described. The author suggests that expensive equipment can limit the growth of a beginning photographer by emphasizing technique and equipment instead of in-depth experience with composition fundamentals and ideas. (KC)

  10. Gamma camera with reflectivity mask

    International Nuclear Information System (INIS)

    Stout, K.J.

    1980-01-01

    In accordance with the present invention there is provided a radiographic camera comprising: a scintillator; a plurality of photodectors positioned to face said scintillator; a plurality of masked regions formed upon a face of said scintillator opposite said photdetectors and positioned coaxially with respective ones of said photodetectors for decreasing the amount of internal reflection of optical photons generated within said scintillator. (auth)

  11. The legacy of care as reflexive learning.

    Science.gov (United States)

    García, Marta Rodríguez; Moya, Jose Luis Medina

    2016-06-14

    to analyze whether the tutor's use of reflexive strategies encourages the students to reflect. The goal is to discover what type of strategies can help to achieve this and how tutors and students behave in the practical context. a qualitative and ethnographic focus was adopted. Twenty-seven students and 15 tutors from three health centers participated. The latter had received specific training on reflexive clinical tutoring. The analysis was developed through constant comparisons of the categories. the results demonstrate that the tutors' use of reflexive strategies such as didactic questioning, didactic empathy and pedagogical silence contributes to encourage the students' reflection and significant learning. reflexive practice is key to tutors' training and students' learning. analisar se o uso de estratégias reflexivas por parte da tutora de estágio clínico estimula a reflexão nos estudantes. A intenção é descobrir qual tipo de estratégias podem ajudar a fazê-lo e como as tutoras e os estudantes se comportam no contexto prático. foi adotado um enfoque qualitativo de cunho etnográfico em que participaram 27 estudantes e 15 tutores de três centros de saúde que haviam recebido formação específica sobre tutoria clínica reflexiva. A análise foi realizada por meio de comparações constantes das categorias. os resultados demonstram que o uso de estratégias reflexivas como a interrogação didática, a empatia didática e o silêncio pedagógico por parte das tutoras, contribui para fomentar a reflexão do estudante e sua aprendizagem significativa. a prática reflexiva é a chave para a formação dos tutores e para a aprendizagem dos estudantes. analizar si el uso de estrategias reflexivas por parte de la tutora de prácticas clínicas fomenta la reflexión en los estudiantes. Se trata de conocer qué tipo de estrategias pueden ayudar a hacerlo y cómo se comportan tutoras y estudiantes en el contexto práctico. se ha utilizado un enfoque

  12. [Acanthamoeba isolation from contact lens solution of contact lens wearers without keratitis].

    Science.gov (United States)

    Watanabe, R; Ishibashi, Y; Hommura, S; Ishii, K

    1994-05-01

    Acanthamoeba keratitis seems to be associated with wearing contact lenses. As controls, we surveyed contact lens wearers without keratitis. Contact lens solutions of 93 persons were examined in order to identify risk factors for contamination by Acanthamoeba. Therefore, the contact lens disinfection system and storage schedules were studied in each case. Acanthamoeba organisms were isolated from 4 specimens (4.3%). The incidence of Acanthamoeba was higher in specimens of soft contact lens solution than in those of hard contact lens solution, and all the Acanthamoeba positive cases had been using tap water.

  13. Primary anterior chamber intraocular lens for the treatment of severe crystalline lens subluxation.

    Science.gov (United States)

    Hoffman, Richard S; Fine, I Howard; Packer, Mark

    2009-10-01

    Subluxated cataractous and clear lenses are commonly treated by limbal or pars plana lensectomy followed by primary or secondary intraocular lens (IOL) implantation. Adjunctive capsular prosthetic devices have facilitated lens removal and IOL centration in these challenging cases but have also added complexity and potential complications to the procedure. Although crystalline lens extraction may be required to clear the visual axis in mild to moderate lens subluxations, we propose insertion of a primary anterior chamber IOL without lens extraction in severe subluxations when the eye is optically aphakic or can be made functionally aphakic following neodymium:YAG laser zonulysis. Two cases demonstrating this approach are presented.

  14. Reflexive Aero Structures for Enhanced Survivability, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Cornerstone Research Group Inc. (CRG) will develop an advanced reflexive structure technology system to increase the survivability of future systems constructed of...

  15. Sympathetic reflex control of blood flow in human peripheral tissues

    DEFF Research Database (Denmark)

    Henriksen, O

    1991-01-01

    sympathetic vasoconstrictor reflexes are blocked. Blood flow has been measure by the local 133Xe-technique. The results indicate the presence of spinal as well as supraspinal sympathetic vasoconstrictor reflexes to human peripheral tissues. Especially is emphasized the presence of a local sympathetic veno......Sympathetic vasoconstrictor reflexes are essential for the maintenance of arterial blood pressure in upright position. It has been generally believed that supraspinal sympathetic vasoconstrictor reflexes elicited by changes in baroreceptor activity play an important role. Recent studies on human...

  16. Reflex sympathetic dystrophy following pacemaker insertion.

    Science.gov (United States)

    Londhey, Vikram A; Singh, Nishant; Kini, Seema

    2011-09-01

    A 55 year old male presented with pain and swelling over dorsum of right hand and small joints, and loss of sweating over right hand since two months. He was a known case of mitral valve prolapse (MVP) with mitral regurgitation and complete heart block for which pacemaker was implanted 1 year back. Bilateral wrist X-ray was suggestive of pronounced demineralization (osteopenia) in the right hand. He was thus diagnosed to have reflex sympathetic dystrophy syndrome (RSDS) considered to be induced by pacemaker insertion. After treatment with amitryptiline and indomethacin his symptoms dramatically improved.

  17. Protection of the eye lens

    International Nuclear Information System (INIS)

    2015-01-01

    The limit of radiation exposure for eye lens is going to decrease dramatically from 150 to 20 mSv as a transposition into the French law of a CIPR (International Commission for Radiation Protection) directive. Sanitary studies have shown that radiologists are more likely by a factor of 3.8 to get eye lens opacities than the rest of the population. The wearing of protective glasses is recommended and in order to get a better monitoring of the radiation dose new dosimeters have been designed, they can be worn on the glass frame of directly stuck on the skin near the eyes. A study has shown that veterinary surgeons that are accustomed to stay near animals to keep them quiet during radiological exams are prone to receive high doses as well as physicians that use hypnosis to decrease the level of anxiety of their patients during radiological exams. Radiation exposure of radiologists can be mitigated through: the use of protective shields and equipment and the optimization of the dose delivered to the patient. (A.C.)

  18. Effects of brainstem lesions on the masseter inhibitory reflex. Functional mechanisms of reflex pathways

    NARCIS (Netherlands)

    Ongerboer de Visser, B. W.; Cruccu, G.; Manfredi, M.; Koelman, J. H.

    1990-01-01

    The masseter inhibitory reflex (MIR) was investigated in 16 patients with localized brainstem lesions involving the trigeminal system. The MIR consists of two phases of EMG silence (S1 and S2) evoked by stimulation of the mental nerve during maximal clenching of the teeth. The extent of the lesions

  19. Ocular Surface Temperature During Scleral Lens Wearing in Patients With Keratoconus.

    Science.gov (United States)

    Carracedo, Gonzalo; Wang, Zicheng; Serramito-Blanco, Maria; Martin-Gil, Alba; Carballo-Alvarez, Jesús; Pintor, Jesús

    2017-11-01

    To evaluate the ocular surface temperature using an infrared thermography camera before and after wearing scleral lens in patients with keratoconus and correlate these results with the tear production and stability. A pilot, experimental, short-term study has been performed. Twenty-six patients with keratoconus (36.95±8.95 years) participated voluntarily in the study. The sample was divided into two groups: patients with intrastromal corneal ring (KC-ICRS group) and patients without ICRS (KC group). Schirmer test, tear breakup time (TBUT), and ocular surface temperature in the conjunctiva, limbus, and cornea were evaluated before and after wearing a scleral lens. The patients wore the scleral lenses from 6 to 9 hours with average of 7.59±0.73 hours. No significant changes in Schirmer test and TBUT were found for both groups. No temperature differences were found between the KC-ICRS and the KC groups for all zones evaluated. There was a slight, but statistically significant, increase in the inferior cornea, temporal limbus, and nasal conjunctival temperature for KC-ICRS group and temporal limbus temperature decreasing for the KC group after wearing scleral lens (Ptemperature was statistically higher than the central cornea for both groups before and after scleral lenses wearing (Pperipheral cornea was found. No statistically significant differences in the central corneal temperature were found between the groups after scleral lens wearing (P>0.05). Scleral contact lens seems not to modify the ocular surface temperature despite the presence of the tear film stagnation under the lens.

  20. Color corrected Fresnel lens for solar concentration

    International Nuclear Information System (INIS)

    Kritchman, E.M.

    1979-01-01

    A new linear convex Fresnel lens with its groove side down is described. The design philosophy is similar to the highly concentrating two focal Fresnel lens but including a correction for chromatic aberration. A solar concentration ratio as high as 80 is achieved. For wide acceptance angles the concentration nears the theoretical maximum. (author)

  1. Modified suturing contact lens for penetrating keratoplasty.

    Science.gov (United States)

    Kramer, S G; Stewart, H L

    1978-11-01

    The authors have previously described a suturing contact lens that protects the corneal endothelium by aiding in the maintenance of the anterior chamber during penetrating keratoplasty. This report describes structural modifications of the suturing contact lens, which improve its stability and effectiveness. An additional configuration for use in corneal lacerations is presented.

  2. Charged black lens in de Sitter space

    Science.gov (United States)

    Tomizawa, Shinya

    2018-02-01

    We obtain a charged black lens solution in the five-dimensional Einstein-Maxwell-Chern-Simons theory with a positive cosmological constant. It is shown that the solution obtained here describes the formation of a black hole with the spatial cross section of a sphere from that of the lens space of L (n ,1 ) in five-dimensional de Sitter space.

  3. Contact Lens Use in the Civil Airman Population

    National Research Council Canada - National Science Library

    Nakagawara, Van

    2002-01-01

    ...) aeromedical certificate. Although contact lens technology has advanced dramatically in recent years, the aviation environment may still have adverse effects on contact lens performance in some flight situations...

  4. Corrected electrostatic lens systems for ion beams

    International Nuclear Information System (INIS)

    Dalgish, R.L.

    1981-01-01

    Recent work in our laboratory has introduced a new class of electrostatic focus forming element for beams, the ELCO lens. It compares favourably with the electrostatic and magnetic quadrupole elements conventionally used for microbeam formation. The ELCO lens does however have disadvantages associated with apertures and alignment. We have continued with the development of ion beam lenses and have evolved a further class of lens element which eliminates aperture and alignment problems. This new element can be combined like optical lenses into an aberration corrected system. Experimental measurement on the basic lens element has confirmed mathematical analysis of ion trajectories through the element. This mathematical analysis predicts that the basic element can be combined into a corrected lens system for, either: (1) high resolution microprobe formation with intrinsic rastering ability, the spot size limited only by the beam properties; or (2) high quality image formation with large magnification/demagnification ratio and wide angular aperture. (orig.)

  5. The family photography in the lens of students’ camera [Rodzina w obiektywie studenckiego aparatu

    Directory of Open Access Journals (Sweden)

    Andrzej ŁADYŻYŃSKI

    2017-11-01

    Full Text Available The paper constitutes an attempt to interpret family photography as vital pedagogical information. Photographies, with their subject: ‘The family’, were taken by the students of the Institute of Pedagogy of the University of Wroclaw. Analysis of the photographs gives a detailed information about the people being photographed, provides knowledge about the prevailing thematic motives, the contextual circumstances, the emotions accompanying the process of taking them and it approximates their social aspect: their social class, sex, and age. It allows the observers to interpret the biographical experiences of the photographers. An endeavour to interpret the photographs presented by students shows an interesting way to understand the concept of the family and a variety of aspects of its functioning

  6. Robotic versus human camera holding in video-assisted thoracic sympathectomy: a single blind randomized trial of efficacy and safety.

    Science.gov (United States)

    Martins Rua, Joaquim Fernando; Jatene, Fabio Biscegli; de Campos, José Ribas Milanez; Monteiro, Rosangela; Tedde, Miguel Lia; Samano, Marcos Naoyuki; Bernardo, Wanderley M; Das-Neves-Pereira, João Carlos

    2009-02-01

    Our objective is to compare surgical safety and efficacy between robotic and human camera control in video-assisted thoracic sympathectomy. A randomized-controlled-trial was performed. Surgical operation was VATS sympathectomy for hyperhidrosis. The trial compared a voice-controlled robot for holding the endoscopic camera robotic group (Ro) to human assisted group (Hu). Each group included 19 patients. Sympathectomy was achieved by electrodessication of the third ganglion. Operations were filmed and images stored. Two observers quantified the number of involuntary and inappropriate movements and how many times the camera was cleaned. Safety criteria were surgical accidents, pain and aesthetical results; efficacy criteria were: surgical and camera use duration, anhydrosis, length of hospitalization, compensatory hyperhidrosis and patient satisfaction. There was no difference between groups regarding surgical accidents, number of involuntary movements, pain, aesthetical results, general satisfaction, number of lens cleaning, anhydrosis, length of hospitalization, and compensatory hyperhidrosis. The number of contacts of the laparoscopic lens with mediastinal structures was lower in the Ro group (Probotic arm in VATS sympathectomy for hyperhidrosis is as safe but less efficient when compared to a human camera-holding assistant.

  7. Neural reflex regulation of arterial pressure in pathophysiological conditions: interplay among the baroreflex, the cardiopulmonary reflexes and the chemoreflex

    Directory of Open Access Journals (Sweden)

    E.C. Vasquez

    1997-04-01

    Full Text Available The maintenance of arterial pressure at levels adequate to perfuse the tissues is a basic requirement for the constancy of the internal environment and survival. The objective of the present review was to provide information about the basic reflex mechanisms that are responsible for the moment-to-moment regulation of the cardiovascular system. We demonstrate that this control is largely provided by the action of arterial and non-arterial reflexes that detect and correct changes in arterial pressure (baroreflex, blood volume or chemical composition (mechano- and chemosensitive cardiopulmonary reflexes, and changes in blood-gas composition (chemoreceptor reflex. The importance of the integration of these cardiovascular reflexes is well understood and it is clear that processing mainly occurs in the nucleus tractus solitarii, although the mechanism is poorly understood. There are several indications that the interactions of baroreflex, chemoreflex and Bezold-Jarisch reflex inputs, and the central nervous system control the activity of autonomic preganglionic neurons through parallel afferent and efferent pathways to achieve cardiovascular homeostasis. It is surprising that so little appears in the literature about the integration of these neural reflexes in cardiovascular function. Thus, our purpose was to review the interplay between peripheral neural reflex mechanisms of arterial blood pressure and blood volume regulation in physiological and pathophysiological states. Special emphasis is placed on the experimental model of arterial hypertension induced by N-nitro-L-arginine methyl ester (L-NAME in which the interplay of these three reflexes is demonstrable

  8. Cameras and settings for optimal image capture from UAVs

    Science.gov (United States)

    Smith, Mike; O'Connor, James; James, Mike R.

    2017-04-01

    Aerial image capture has become very common within the geosciences due to the increasing affordability of low payload (markets. Their application to surveying has led to many studies being undertaken using UAV imagery captured from consumer grade cameras as primary data sources. However, image quality and the principles of image capture are seldom given rigorous discussion which can lead to experiments being difficult to accurately reproduce. In this contribution we revisit the underpinning concepts behind image capture, from which the requirements for acquiring sharp, well exposed and suitable imagery are derived. This then leads to discussion of how to optimise the platform, camera, lens and imaging settings relevant to image quality planning, presenting some worked examples as a guide. Finally, we challenge the community to make their image data open for review in order to ensure confidence in the outputs/error estimates, allow reproducibility of the results and have these comparable with future studies. We recommend providing open access imagery where possible, a range of example images, and detailed metadata to rigorously describe the image capture process.

  9. Performance of Very Small Robotic Fish Equipped with CMOS Camera

    Directory of Open Access Journals (Sweden)

    Yang Zhao

    2015-10-01

    Full Text Available Underwater robots are often used to investigate marine animals. Ideally, such robots should be in the shape of fish so that they can easily go unnoticed by aquatic animals. In addition, lacking a screw propeller, a robotic fish would be less likely to become entangled in algae and other plants. However, although such robots have been developed, their swimming speed is significantly lower than that of real fish. Since to carry out a survey of actual fish a robotic fish would be required to follow them, it is necessary to improve the performance of the propulsion system. In the present study, a small robotic fish (SAPPA was manufactured and its propulsive performance was evaluated. SAPPA was developed to swim in bodies of freshwater such as rivers, and was equipped with a small CMOS camera with a wide-angle lens in order to photograph live fish. The maximum swimming speed of the robot was determined to be 111 mm/s, and its turning radius was 125 mm. Its power consumption was as low as 1.82 W. During trials, SAPPA succeeded in recognizing a goldfish and capturing an image of it using its CMOS camera.

  10. Cough reflex sensitization from esophagus and nose

    Science.gov (United States)

    Hennel, Michal; Brozmanova, Mariana; Kollarik, Marian

    2015-01-01

    The diseases of the esophagus and nose are among the major factors contributing to chronic cough although their role in different patient populations is debated. Studies in animal models and in humans show that afferent C-fiber activators applied on esophageal or nasal mucosa do not initiate cough, but enhance cough induced by inhaled irritants. These results are consistent with the hypothesis that activation of esophageal and nasal C-fibers contribute to cough reflex hypersensitivity observed in chronic cough patients with gastroesophageal reflux disease (GERD) and chronic rhinitis, respectively. The afferent nerves mediating cough sensitization from the esophagus are probably the neural crest-derived vagal jugular C-fibers. In addition to their responsiveness to high concentration of acid typical for gastroesophageal reflux (pHcough sensitization are less understood. Increased cough reflex sensitivity was also reported in many patients with GERD or rhinitis who do not complain of cough indicating that additional endogenous or exogenous factors may be required to develop chronic coughing in these diseases. PMID:26498387

  11. Venoarteriolar reflex responses in diabetic patients.

    Science.gov (United States)

    Stoyneva, Z; Velcheva, I; Antonova, N; Titianova, E; Koleva, I

    2017-01-01

    The aim of this study was to investigate the venoarteriolar reflex (VAR) responses in type 1 (T1DM) and type 2 (T2DM) diabetes mellitus (DM) with polyneuropathy and to estimate their relationship with age, DM duration, initial cutaneous temperature and body mass index. Four groups of subjects were investigated: 1st group -20 patients with T1DM; 2nd group -50 patients with T2DM; 3rd group of 20 healthy subjects with similar age and body mass index (BMI) to the T1DM group; 4th group (Control2) of 24 healthy subjects adjusted by age and BMI to the T2DM group. The cutaneous perfusions of the big toe pulp were monitored as baseline perfusions at a temperature of 32°C in supine and sitting position with hanging legs and back in supine position. Loss of venoarteriolar reflex responses was established in 75% of T1DM patients, 78% of T2DM patients and in none of the investigated healthy controls. Reduced venoarteriolar perfusion responses were established in both T1DM and T2DM patients with polyneuropathy compared with healthy subjects. Reliable positive associations between VAR responses and the age, DM duration and initial cutaneous temperature were found.

  12. Wh-filler-gap dependency formation guides reflexive antecedent search

    Directory of Open Access Journals (Sweden)

    Michael eFrazier

    2015-10-01

    Full Text Available Prior studies on online sentence processing have shown that the parser can resolve non-local dependencies rapidly and accurately. This study investigates the interaction between the processing of two such non-local dependencies: wh-filler-gap dependencies (WhFGD and reflexive-antecedent dependencies. We show that reflexive-antecedent dependency resolution is sensitive to the presence of a WhFGD, and argue that the filler-gap dependency established by WhFGD resolution is selected online as the antecedent of a reflexive dependency. We investigate the processing of constructions like (1, where two NPs might be possible antecedents for the reflexive, namely which cowgirl and Mary. Even though Mary is linearly closer to the reflexive, the only grammatically licit antecedent for the reflexive is the more distant wh-NP, which cowgirl. 1. Which cowgirl did Mary expect to have injured herself due to negligence?Four eye-tracking text-reading experiments were conducted on examples like (1, differing in whether the embedded clause was non-finite (1 and 3 or finite (2 and 4, and in whether the tail of the wh-dependency intervened between the reflexive and its closest overt antecedent (1 and 2 or the wh-dependency was associated with a position earlier in the sentence (3 and 4.The results of Experiments 1 and 2 indicate the parser accesses the result of WhFGD formation during reflexive antecedent search. The resolution of a wh-dependency alters the representation that reflexive antecedent search operates over, allowing the grammatical but linearly distant antecedent to be accessed rapidly. In the absence of a long-distance WhFGD (Exp. 3 and 4, wh-NPs were not found to impact reading times of the reflexive, indicating that the parser's ability to select distant wh-NPs as reflexive antecedents crucially involves syntactic structure.

  13. A planar-dimensions machine vision measurement method based on lens distortion correction.

    Science.gov (United States)

    Sun, Qiucheng; Hou, Yueqian; Tan, Qingchang; Li, Guannan

    2013-01-01

    Lens distortion practically presents in a real optical imaging system causing nonuniform geometric distortion in the images and gives rise to additional errors in the vision measurement. In this paper, a planar-dimensions vision measurement method is proposed by improving camera calibration, in which the lens distortion is corrected on the pixel plane of image. The method can be divided into three steps: firstly, the feature points, only in the small central region of the image, are used to get a more accurate perspective projection model; secondly, rather than defining a uniform model, the smoothing spline function is used to describe the lens distortion in the measurement region of image, and two correction functions can be obtained by fitting two deviation surfaces; finally, a measurement method for planar dimensions is proposed, in which accurate magnification factor of imaging system can be obtained by using the correction functions. The effectiveness of the method is demonstrated by applying the proposed method to the test of measuring shaft diameter. Experimental data prove that the accurate planar-dimensions measurements can be performed using the proposed method even if images are deformed by lens distortion.

  14. Incidence of irregular astigmatism eligible for contact lens fitting after Descemet membrane endothelial keratoplasty.

    Science.gov (United States)

    van Dijk, Korine; Parker, Jack; Liarakos, Vasilios S; Ham, Lisanne; Frank, Laurence E; Melles, Gerrit R J

    2013-07-01

    To evaluate the incidence and causes of anterior corneal surface irregularities after successful Descemet membrane endothelial keratoplasty (DMEK) and the efficacy of contact lens fitting in these cases. Tertiary referral center. Retrospective study of prospectively collected data. Eyes with a subnormal visual outcome or monocular diplopia after successful DMEK were fitted with a contact lens. These cases were evaluated with Pentacam rotating Scheimpflug camera imaging preoperatively and 6 months postoperatively, and outcomes were compared with those in a randomly selected DMEK control group. In a series of 262 surgeries, 23 eyes (21 patients) were fitted with contact lenses; the control group comprised 23 eyes. Indications for contact lens fitting included (1) obvious corneal surface irregularities due to preexisting corneal scarring, (2) surface irregularities associated with longstanding preoperative stromal edema, and (3) undetectable optical imperfections. The postoperative corrected distance visual acuity (CDVA) with spectacles improved after contact lens correction (PDutch Ophthalmic USA. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. Architectural Design Document for Camera Models

    DEFF Research Database (Denmark)

    Thuesen, Gøsta

    1998-01-01

    Architecture of camera simulator models and data interface for the Maneuvering of Inspection/Servicing Vehicle (MIV) study.......Architecture of camera simulator models and data interface for the Maneuvering of Inspection/Servicing Vehicle (MIV) study....

  16. Graphic design of pinhole cameras

    Science.gov (United States)

    Edwards, H. B.; Chu, W. P.

    1979-01-01

    The paper describes a graphic technique for the analysis and optimization of pinhole size and focal length. The technique is based on the use of the transfer function of optical elements described by Scott (1959) to construct the transfer function of a circular pinhole camera. This transfer function is the response of a component or system to a pattern of lines having a sinusoidally varying radiance at varying spatial frequencies. Some specific examples of graphic design are presented.

  17. The Use of Camera Traps in Wildlife

    OpenAIRE

    Yasin Uçarlı; Bülent Sağlam

    2013-01-01

    Camera traps are increasingly used in the abundance and density estimates of wildlife species. Camera traps are very good alternative for direct observation in case, particularly, steep terrain, dense vegetation covered areas or nocturnal species. The main reason for the use of camera traps is eliminated that the economic, personnel and time loss in a continuous manner at the same time in different points. Camera traps, motion and heat sensitive, can take a photo or video according to the mod...

  18. Stereo Pinhole Camera: Assembly and experimental activities

    OpenAIRE

    Santos, Gilmário Barbosa; Departamento de Ciência da Computação, Universidade do Estado de Santa Catarina, Joinville; Cunha, Sidney Pinto; Centro de Tecnologia da Informação Renato Archer, Campinas

    2015-01-01

    This work describes the assembling of a stereo pinhole camera for capturing stereo-pairs of images and proposes experimental activities with it. A pinhole camera can be as sophisticated as you want, or so simple that it could be handcrafted with practically recyclable materials. This paper describes the practical use of the pinhole camera throughout history and currently. Aspects of optics and geometry involved in the building of the stereo pinhole camera are presented with illustrations. Fur...

  19. Investigation of lens morphology and mechanical characteristics of lens capsule and lens nucleus in patients with agerelated and diabetic cataract

    Directory of Open Access Journals (Sweden)

    A. S. Tishkova

    2014-07-01

    Full Text Available Purpose: To investigate the influence of carbohydrate metabolism on the structure and mechanical properties of the lens capsule and nucleus.Methods: Human lens pathology was studied in different forms of cataract. 220 patients with a cataract (220 eyes were included in this study. Morphological, immunohystological and immunocytochemical investigations of lens substance (antibodies to a- (a-А and a-В, b-, g- crystallines, spectroscopic analyses of smears and morphometric analyses of slices, investigation of lens morphology and mechanical caracteristics of lens capsule and lens nucleus were performed.Results: The capsule of the lens in patients with senile cataract contains more Na+, Cl-. The capsule of the lens in patients with senile cataract contains more Ca2+, O. Mechanical strength of the capsule in the case of diabetes mellitus was lower comparatively with senile cataract in the same age groups. More significant expression of a-В and b-crystallines was found in patients with diabetes mellitus comparatively with patients with age-related cataract. Morphological features were founded in patients with cortical and nuclear forms of senile cataract and the diabetic cataract.Conclusion: During surgery (ultrasonic microcoaxial phacoemulsification the equivalent of ultrasound was recorded. Lower density of the lens nucleus of patients with diabetes mellitus made it possible to use lower energy parameters. Using the torsion ultrasound in those cases allowed us to decrease the influence of ultrasound on eye tissues and reduce the time of achieving the maximum BCVA in the postsurgical period.

  20. Investigation of lens morphology and mechanical characteristics of lens capsule and lens nucleus in patients with agerelated and diabetic cataract

    Directory of Open Access Journals (Sweden)

    A. S. Tishkova

    2013-01-01

    Full Text Available Purpose: To investigate the influence of carbohydrate metabolism on the structure and mechanical properties of the lens capsule and nucleus.Methods: Human lens pathology was studied in different forms of cataract. 220 patients with a cataract (220 eyes were included in this study. Morphological, immunohystological and immunocytochemical investigations of lens substance (antibodies to a- (a-А and a-В, b-, g- crystallines, spectroscopic analyses of smears and morphometric analyses of slices, investigation of lens morphology and mechanical caracteristics of lens capsule and lens nucleus were performed.Results: The capsule of the lens in patients with senile cataract contains more Na+, Cl-. The capsule of the lens in patients with senile cataract contains more Ca2+, O. Mechanical strength of the capsule in the case of diabetes mellitus was lower comparatively with senile cataract in the same age groups. More significant expression of a-В and b-crystallines was found in patients with diabetes mellitus comparatively with patients with age-related cataract. Morphological features were founded in patients with cortical and nuclear forms of senile cataract and the diabetic cataract.Conclusion: During surgery (ultrasonic microcoaxial phacoemulsification the equivalent of ultrasound was recorded. Lower density of the lens nucleus of patients with diabetes mellitus made it possible to use lower energy parameters. Using the torsion ultrasound in those cases allowed us to decrease the influence of ultrasound on eye tissues and reduce the time of achieving the maximum BCVA in the postsurgical period.

  1. An Open Standard for Camera Trap Data

    NARCIS (Netherlands)

    Forrester, Tavis; O'Brien, Tim; Fegraus, Eric; Jansen, P.A.; Palmer, Jonathan; Kays, Roland; Ahumada, Jorge; Stern, Beth; McShea, William

    2016-01-01

    Camera traps that capture photos of animals are a valuable tool for monitoring biodiversity. The use of camera traps is rapidly increasing and there is an urgent need for standardization to facilitate data management, reporting and data sharing. Here we offer the Camera Trap Metadata Standard as an

  2. A camera specification for tendering purposes

    International Nuclear Information System (INIS)

    Lunt, M.J.; Davies, M.D.; Kenyon, N.G.

    1985-01-01

    A standardized document is described which is suitable for sending to companies which are being invited to tender for the supply of a gamma camera. The document refers to various features of the camera, the performance specification of the camera, maintenance details, price quotations for various options and delivery, installation and warranty details. (U.K.)

  3. Calibration method for projector-camera-based telecentric fringe projection profilometry system.

    Science.gov (United States)

    Liu, Haibo; Lin, Huijing; Yao, Linshen

    2017-12-11

    By combining a fringe projection setup with a telecentric lens, a fringe pattern could be projected and imaged within a small area, making it possible to measure the three-dimensional (3D) surfaces of micro-components. This paper focuses on the flexible calibration of the fringe projection profilometry (FPP) system using a telecentric lens. An analytical telecentric projector-camera calibration model is introduced, in which the rig structure parameters remain invariant for all views, and the 3D calibration target can be located on the projector image plane with sub-pixel precision. Based on the presented calibration model, a two-step calibration procedure is proposed. First, the initial parameters, e.g., the projector-camera rig, projector intrinsic matrix, and coordinates of the control points of a 3D calibration target, are estimated using the affine camera factorization calibration method. Second, a bundle adjustment algorithm with various simultaneous views is applied to refine the calibrated parameters, especially the rig structure parameters and coordinates of the control points forth 3D target. Because the control points are determined during the calibration, there is no need for an accurate 3D reference target, whose is costly and extremely difficult to fabricate, particularly for tiny objects used to calibrate the telecentric FPP system. Real experiments were performed to validate the performance of the proposed calibration method. The test results showed that the proposed approach is very accurate and reliable.

  4. Cuba Through A New Lens

    Directory of Open Access Journals (Sweden)

    Jean Stubbs

    2008-12-01

    Full Text Available [First paragraph] The Origins of the Cuban Revolution Reconsidered. Samuel Farber. Chapel Hill: University of North Carolina Press, 2006. x + 212 pp. (Paper US$ 19.95 Cuba: A New History. Ric hard Gott . New Haven: Yale University Press, 2005. xii + 384 pp. (Paper US$ 17.00 Havana: The Making of Cuban Culture. Antoni Kapcia. Oxford: Berg Publishers, 2005. xx + 236 pp. (Paper US$ 24.95 Richard Gott, Antoni Kapcia, and Samuel Farber each approach Cuba through a new lens. Gott does so by providing a broad-sweep history of Cuba, which is epic in scope, attaches importance to social as much as political and economic history, and blends scholarship with flair. Kapcia homes in on Havana as the locus for Cuban culture, whereby cultural history becomes the trope for exploring not only the city but also Cuban national identity. Farber revisits his own and others’ interpretations of the origins of the Cuban Revolution.

  5. Radiation studies in Lens culinaris

    International Nuclear Information System (INIS)

    Sinha, S.S.N.

    1977-01-01

    Estimation of chromosomal aberrations in flowers of Lens culinaris according to their sequence of development in the plants at 4, 8 and 12 Kr in the M 1 generation, showed that the later formed flowers had smaller percentages of cells with aberrations than those developed earlier. It is suggested that this may be the result of competition between more damaged and less damaged cells during the development of the shoot. There is consequently a decrease of sterility in successive flowers. The numbers of karyotypes taking part in the formation of lower and uppermost flowers were estimated cytologically at 4, 8 and 12 Kr. It was found that more karyotypes were involved in the formation of the lower flowers than in the upper ones. It appeared that at lower doses larger numbers of karyotypes were taking part in the formation of the chimaera than at higher doses. (auth.)

  6. Iris Pigmentation and Fractionated Reaction and Reflex Time.

    Science.gov (United States)

    Hale, Bruce D.; And Others

    Behavioral measures, fractionated reaction and reflex times by means of electromyography, were used to determine if the eye color differences are found in the central or peripheral regions of the nervous system. The purpose of this research was to determine the truth of the hypothesis that dark-eyed individuals have faster reflex and reaction time…

  7. Low Incidence Of Extensor Plantar Reflex In Newborns In An ...

    African Journals Online (AJOL)

    Healthy term newborns with Apgar score of 8 and above at one minute were recruited into the study consecutively in a maternity hospital in Ibadan, Nigeria. The plantar reflex was elicited by stroking the lateral side of the sole with firm pressure, between 24 - 48 hours after delivery. Results Of 461 newborns, the plantar reflex ...

  8. On the Property of Reflexivity for Multiplication Operators on Banach ...

    Indian Academy of Sciences (India)

    21

    operator Mz are reflexive on a Banach space of functions analytic on a plane domain. AMS Subject Classification: 47B37; 46A25. Keywords: Banach spaces of analytic functions, multiplication operators, reflexive oper- ator, multipliers, Caratheodory hull, bounded point evaluation, spectral set. Introduction. For any set E and ...

  9. Ultimate concerns in late modernity: Archer, Bourdieu and reflexivity.

    Science.gov (United States)

    Farrugia, David; Woodman, Dan

    2015-12-01

    Through a critique of Margaret Archer's theory of reflexivity, this paper explores the theoretical contribution of a Bourdieusian sociology of the subject for understanding social change. Archer's theory of reflexivity holds that conscious 'internal conversations' are the motor of society, central both to human subjectivity and to the 'reflexive imperative' of late modernity. This is established through critiques of Bourdieu, who is held to erase creativity and meaningful personal investments from subjectivity, and late modernity is depicted as a time when a 'situational logic of opportunity' renders embodied dispositions and the reproduction of symbolic advantages obsolete. Maintaining Archer's focus on 'ultimate concerns' in a context of social change, this paper argues that her theory of reflexivity is established through a narrow misreading and rejection of Bourdieu's work, which ultimately creates problems for her own approach. Archer's rejection of any pre-reflexive dimensions to subjectivity and social action leaves her unable to sociologically explain the genesis of 'ultimate concerns', and creates an empirically dubious narrative of the consequences of social change. Through a focus on Archer's concept of 'fractured reflexivity', the paper explores the theoretical necessity of habitus and illusio for understanding the social changes that Archer is grappling with. In late modernity, reflexivity is valorized just as the conditions for its successful operation are increasingly foreclosed, creating 'fractured reflexivity' emblematic of the complex contemporary interaction between habitus, illusio, and accelerating social change. © London School of Economics and Political Science 2015.

  10. [The development of I. P. Pavlov's conditioned reflex theory].

    Science.gov (United States)

    Kim, O J

    1992-01-01

    This paper deals with the theory of Ivan Petrovich Pavlov (1849-1936), a Russian physiologist who presented for the first time the systematic theory of the function of the brain that controls the whole behavior of animals, i.e. higher nervous activity through experimental studies. This paper, principally based on Lectures on Conditioned Reflexes (1928), investigates the development of conditioned reflex theory from its beginning by dividing it into three periods. First, during the period from 1898 to 1906, the fundamental concept of conditioned reflex was established and the study of conditioned reflex became an independent discipline. From 1907 to 1916, the second period, Pavlov theorized on higher nervous activity on the basis of extensive data from his laboratory experiments of conditioned reflex. And Pavlov complemented conditioned reflex theory, during the third period from 1916 to 1928, and extended the boundaries of it through applications of conditioned reflex theory to psychopathology and typology. The study contributes to the understanding that conditioned reflex theory was historically developed, and not presented as a complete form from the beginning, and that Pavlov intended to study the higher nervous activity through the method of neurophysiology.

  11. Lemmatization of reflexives in Northern Sotho | Prinsloo | Lexikos

    African Journals Online (AJOL)

    The aim of this article is to evaluate current strategies in the lemmatization of reflexives in Northern Sotho. In particular the so-called "traditional" approach according to which reflexives are lemmatized randomly, as well as the more "rule orientated" alternative, will be critically evaluated mainly against the background of ...

  12. Reflexivity as a control factor of personal coping behavior

    OpenAIRE

    BEKHTER A.A.

    2014-01-01

    The article deals with the issue of coping behavior control. The author defines the criteria, levels and aspects of reflexivity within the framework of personal coping behavior. In conclusion the author describes the key facets of coping behavior control and how reflexivity affects them.

  13. Epithelioid sarcoma presenting as the reflex sympathetic dystrophy syndrome.

    Science.gov (United States)

    Summers, C. L.; Shahi, M.

    1987-01-01

    A case of reflex sympathetic dystrophy caused by an epithelioid sarcoma is presented. This is the first report of a local peripheral tumour associated with the reflex sympathetic dystrophy syndrome. Images Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 PMID:3671265

  14. Reflex sympathetic dystrophy: Early treatment and psychological aspects

    NARCIS (Netherlands)

    Geertzen, J.H.B.; De Bruijn, H.; De Bruijn-Kofman, A.T.; Arendzen, J.H.

    1994-01-01

    We report the results of two prospective studies of early treatment and psychological aspects in a series of 26 patients with sympathetic reflex dystrophy of the hand in which treatment was started within 3 months after diagnosis. Ismelin blocks is an often used therapy in sympathetic reflex

  15. 21 CFR 890.1450 - Powered reflex hammer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Powered reflex hammer. 890.1450 Section 890.1450 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... hammer. (a) Identification. A powered reflex hammer is a motorized device intended for medical purposes...

  16. Microbial contamination of contact lens storage cases and domestic tap water of contact lens wearers.

    Science.gov (United States)

    Üstüntürk, Miray; Zeybek, Zuhal

    2012-11-01

    Contact lenses have been widely used as an alternative to spectacles both in developed and developing countries. However, under certain circumstances, adverse responses can occur during contact lens wear and several microorganisms--including bacteria, fungi, and free living amoebae--can cause several eye infections in wearers. Extended wear of contact lenses is the major risk factor of eye infections such as microbial keratitis, besides contaminated contact lens storage case, contaminated lens care solutions, and inaccurate contact lens handling. In this study, we collected contact lens storage case and domestic tap water samples from 50 asymptomatic contact lens wearers. We determined that total aerobic mesophilic bacteria were isolated in 45 (90 %), Gram negative rod bacteria were isolated in 20 (40 %), Pseudomonas spp. were isolated in 2 (4 %) and fungi were isolated in 18 (36 %) out of 50 contact lens storage cases. Free living amoebae were not detected in investigated contact lens storage cases. At the same time, out of 50, total aerobic mesophilic bacteria were isolated in 34 (68 %), fungi were isolated in 15 (30 %) and free living amoebae were isolated in 15 (30 %) domestic tap water samples. No Gram-negative rod bacteria and Pseudomonas spp. were detected in investigated water samples. Two contact lens case samples and two tap water samples were excluded from the analysis for Pseudomonas spp. for technical reasons. According to our findings, inadequate contact lens maintenance during lens wear may result in the contamination of contact lens storage cases. This situation can lead to severe eye infections in contact lens wearers over time.

  17. GOLDEN GRAVITATIONAL LENSING SYSTEMS FROM THE SLOAN LENS ACS SURVEY. I. SDSS J1538+5817: ONE LENS FOR TWO SOURCES ,

    International Nuclear Information System (INIS)

    Grillo, C.; Seitz, S.; Bender, R.; Eichner, T.; Bauer, A.; Lombardi, M.; Gobat, R.

    2010-01-01

    We present a gravitational lensing and photometric study of the exceptional strong lensing system SDSS J1538+5817, identified by the Sloan Lens Advanced Camera for Survey. The lens is a luminous elliptical galaxy at redshift z l = 0.143. Using Hubble Space Telescope public images obtained with two different filters, the presence of two background sources lensed, respectively, into an Einstein ring and a double system is ascertained. Our new spectroscopic observations, performed at the Nordic Optical Telescope, reveal unequivocally that the two sources are located at the same redshift z s = 0.531. We investigate the total (luminous and dark) mass distribution of the lens between 1 and 4 kpc from the galaxy center by means of parametric and non-parametric lensing codes that describe the multiple images as point-like objects. Bootstrapping and Bayesian analyses are performed to determine the uncertainties on the quantities relevant to the lens mass characterization. Several disparate lensing models provide results that are consistent, given the errors, with those obtained from the best-fit model of the lens mass distribution in terms of a singular power-law ellipsoid model. In particular, the lensing models agree on: (1) reproducing accurately the observed positions of the images; (2) predicting a nearly axisymmetric total mass distribution, centered and oriented as the light distribution; (3) measuring a value of 8.11 +0.27 -0.59 x 10 10 M sun for the total mass projected within the Einstein radius of 2.5 kpc; and (4) estimating a total mass density profile slightly steeper than an isothermal one (ρ(r)∝r -2.33 +0.43 -0.20 ). A fit of the Sloan Digital Sky Survey multicolor photometry with composite stellar population models provides a value of 20 +1 -4 x 10 10 M sun for the total mass of the galaxy in the form of stars and of 0.9 +0.1 -0.2 for the fraction of projected luminous over total mass enclosed inside the Einstein radius. By combining lensing (total) and

  18. A Critical Reflexive Perspective on Othering in Collaborative Knowledge Production

    DEFF Research Database (Denmark)

    Nordentoft, Helle Merete; Olesen, Birgitte Ravn

    2018-01-01

    -reflexive analyses of reflexive processes within collaborative knowledge production We use an analytical framework combining Bakhtin and Foucault to investigate processes of inclusion and exclusion in the interplay between dominant and subordinated voices in a moment-by-moment analysis of two incidents from...... interdisciplinary workshops. Findings The analysis illuminates how differences between voices challenge participants’ reflexive awareness and lead to the reproduction of contextual power and knowledge hierarchies and the concomitant silencing of particular participants. Thus, the findings draw attention...... to the complex and ethical nature of collaborative knowledge production. Practical implications To invite researchers to be reflexive about the complex, situated and emergent character of reflexive processes and consider ethics to be a critical stance that encourages continuous reflection and critique...

  19. Stretch reflex regulation in healthy subjects and patients with spasticity

    DEFF Research Database (Denmark)

    Nielsen, Jens Bo; Petersen, Nicolas; Crone, Clarissa

    2005-01-01

    In recent years, part of the muscle resistance in spastic patients has been explained by changes in the elastic properties of muscles. However, the adaptive spinal mechanisms responsible for the exaggeration of stretch reflex activity also contribute to muscle stiffness. The available data suggest...... of the spastic symptoms. A recent finding also shows no sign of exaggerated stretch reflexes in muscles voluntarily activated by the spastic patient in general. This is easily explained by the control of stretch reflex activity in healthy subjects. In healthy subjects, the stretch reflex activity is increased...... movements, antagonist muscles should remain silent and maximally relaxed. This is ensured by increasing transmission in several spinal inhibitory pathways. In spastic patients, this control is inadequate, and therefore stretch reflexes in antagonist muscles are easily evoked at the beginning of voluntary...

  20. Sympathetic reflex control of blood flow in human peripheral tissues

    DEFF Research Database (Denmark)

    Henriksen, O

    1991-01-01

    sympathetic vasoconstrictor reflexes are blocked. Blood flow has been measure by the local 133Xe-technique. The results indicate the presence of spinal as well as supraspinal sympathetic vasoconstrictor reflexes to human peripheral tissues. Especially is emphasized the presence of a local sympathetic veno......Sympathetic vasoconstrictor reflexes are essential for the maintenance of arterial blood pressure in upright position. It has been generally believed that supraspinal sympathetic vasoconstrictor reflexes elicited by changes in baroreceptor activity play an important role. Recent studies on human...... skeletal muscle, cutaneous and subcutaneous tissues of the limbs indicate that the situation is more complex. Measurements have been carried out during acute as well as chronic sympathetic denervation. Spinal sympathetic reflex mechanisms have been evaluated in tetraplegic patients, where supraspinal...

  1. Prevalence of family history in patients with reflex syncope

    DEFF Research Database (Denmark)

    Holmegard, Haya N; Benn, Marianne; Kaijer, Michelle Nymann

    2013-01-01

    among subtypes of reflex syncope, as these have different autonomic responses and pathogeneses may be diverse. The present study aimed to assess the prevalence of a positive family history of syncope and cardiovascular characteristics in patients with cardioinhibitory and vasodepressor reflex syncope......Reflex syncope is defined by a rapid transient loss of consciousness caused by global cerebral hypoperfusion resulting from vasodilatation and/or bradycardia attributable to inappropriate cardiovascular reflexes. A hereditary component has been suggested, but prevalence of family history may differ....... Patients (n=74) were classified into subtypes of reflex syncope - cardioinhibition/asystole (Vasovagal Syncope International Study subtypes II-B [VASIS II-B], n=38) or vasodepressor (VASIS III, n=36) - using the head-up tilt test. Family history was obtained by questionnaires supplemented by interview...

  2. Voluntary Control of the Near Reflex: A Case Report

    Directory of Open Access Journals (Sweden)

    Serpil Akar

    2014-03-01

    Full Text Available Spasm of the near reflex is a rare disorder that involves intermittent and variable episodes of esotropia, pseudomyopia, and pupillary myosis. It is usually functional in origin and is seen mainly in young patients. Treatment options for spasm of the near reflex have had variable success. In instances where the etiology of spasm of the near reflex was suspected to be hysteria, psychotherapy has proven beneficial. We report the case of an 11-year-old girl who had functional spasm of the near reflex. The symptoms persisted for two years. Symptomatic relief was achieved by cycloplegia and spectacle correction (added plus lenses at near. The patient also underwent psychological counseling. In our case, the functional spasm of the near reflex spontaneously resolved after 2 years. (Turk J Ophthalmol 2014; 44: 161-3

  3. Relative camera localisation in non-overlapping camera networks using multiple trajectories

    NARCIS (Netherlands)

    John, V.; Englebienne, G.; Kröse, B.J.A.

    2012-01-01

    In this article we present an automatic camera calibration algorithm using multiple trajectories in a multiple camera network with non-overlapping field-of-views (FOV). Visible trajectories within a camera FOV are assumed to be measured with respect to the camera local co-ordinate system.

  4. Modelling Virtual Camera Behaviour Through Player Gaze

    DEFF Research Database (Denmark)

    Picardi, Andrea; Burelli, Paolo; Yannakakis, Georgios N.

    2012-01-01

    In a three-dimensional virtual environment, aspects such as narrative and interaction largely depend on the placement and animation of the virtual camera. Therefore, virtual camera control plays a critical role in player experience and, thereby, in the overall quality of a computer game. Both game...... on the relationship between virtual camera, game-play and player behaviour. We run a game user experiment to shed some light on this relationship and identify relevant dif- ferences between camera behaviours through different game sessions, playing behaviours and player gaze patterns. Re- sults show that users can...... be efficiently profiled in dissimilar clusters according to camera control as part of their game- play behaviour....

  5. Stereo Pinhole Camera: Assembly and experimental activities

    Directory of Open Access Journals (Sweden)

    Gilmário Barbosa Santos

    2015-05-01

    Full Text Available This work describes the assembling of a stereo pinhole camera for capturing stereo-pairs of images and proposes experimental activities with it. A pinhole camera can be as sophisticated as you want, or so simple that it could be handcrafted with practically recyclable materials. This paper describes the practical use of the pinhole camera throughout history and currently. Aspects of optics and geometry involved in the building of the stereo pinhole camera are presented with illustrations. Furthermore, experiments are proposed by using the images obtained by the camera for 3D visualization through a pair of anaglyph glasses, and the estimation of relative depth by triangulation is discussed.

  6. Adapting virtual camera behaviour through player modelling

    DEFF Research Database (Denmark)

    Burelli, Paolo; Yannakakis, Georgios N.

    2015-01-01

    Research in virtual camera control has focused primarily on finding methods to allow designers to place cameras effectively and efficiently in dynamic and unpredictable environments, and to generate complex and dynamic plans for cinematography in virtual environments. In this article, we propose...... a novel approach to virtual camera control, which builds upon camera control and player modelling to provide the user with an adaptive point-of-view. To achieve this goal, we propose a methodology to model the player’s preferences on virtual camera movements and we employ the resulting models to tailor...

  7. Reflexive regulation of CSR to promote sustainablility

    DEFF Research Database (Denmark)

    Buhmann, Karin

    This article discusses Corporate Social Responsibility (CSR) from the perspective of governmental regulation as a measure to promote public policy interests through public-private regulation intended to influence firms’ self-regulation. Presenting a ‘government case’ for CSR, the connection between...... in order to balance power disparities among participants. Finally, the analysis suggests that a juridification of CSR is taking place. This development is welcome because legal theory and scholarship’s insight into institutionalisation of norms of conduct has much to offer to society’s interests...... in promoting companies’ responsibility with regard to aspects of sustainable development, such as climate impact. Keywords: Sustainable development, sustainable companies, reflexive regulation, climate change, CSR, EU law, public-private regulation, companies' self-regulation...

  8. Reflexive regulation of CSR to promote sustainability

    DEFF Research Database (Denmark)

    Buhmann, Karin

    2011-01-01

    This article discusses Corporate Social Responsibility (CSR) from the perspective of governmental regulation as a measure to promote public policy interests through public-private regulation intended to influence firms’ self-regulation. Presenting a ‘government case’ for CSR, the connection between...... and the EU CSR Alliance. Focusing on human rights based in international law, it analyses the patterns of negotiation in the MSF and the background for the launch of the CSR Alliance. It shows that analysing public-private regulation of CSR from the perspective of reflexive law theory assists us...... climate change and environmental sustainability, and social, economic and other human rights lend human rights as part of CSR a potential for meeting some environmental and climate concerns and handling adverse side-effects. The article analyses two EU initiatives: The EU Multi-Stakeholder (MSF) on CSR...

  9. Study of the Reflex-Klystron

    International Nuclear Information System (INIS)

    Valencia A, R.

    1981-01-01

    The main purpose of this paper is the theoretical study and the development of a technique for designing. A low power Reflex-Klystron, in order to construct it in the graduated section laboratories of the Instituto Politecnico Nacional. It is pretended to attain a power of 15-45 m W in frequencies of 8-10 GHz with low acceleration potentials (300-400 V) and electric current of 15-25 m A; the device will be mechanically tuned and will have a fine tuning through the potential of the reflector (150-180 V negative with respect to the resonator). The International System of Units is used in this thesis. (Author)

  10. Transferability of glass lens molding

    Science.gov (United States)

    Katsuki, Masahide

    2006-02-01

    Sphere lenses have been used for long time. But it is well known that sphere lenses theoretically have spherical aberration, coma and so on. And, aspheric lenses attract attention recently. Plastic lenses are molded easily with injection machines, and are relatively low cost. They are suitable for mass production. On the other hand, glass lenses have several excellent features such as high refractive index, heat resistance and so on. Many aspheric glass lenses came to be used for the latest digital camera and mobile phone camera module. It is very difficult to produce aspheric glass lenses by conventional process of curve generating and polishing. For the solution of this problem, Glass Molding Machine was developed and is spreading through the market. High precision mold is necessary to mold glass lenses with Glass Molding Machine. The mold core is ground or turned by high precision NC aspheric generator. To obtain higher transferability of the mold core, the function of the molding machine and the conditions of molding are very important. But because of high molding temperature, there are factors of thermal expansion and contraction of the mold and glass material. And it is hard to avoid the factors. In this session, I introduce following items. [1] Technology of glass molding and the machine is introduced. [2] The transferability of glass molding is analyzed with some data of glass lenses molded. [3] Compensation of molding shape error is discussed with examples.

  11. Initial laboratory evaluation of color video cameras

    Energy Technology Data Exchange (ETDEWEB)

    Terry, P L

    1991-01-01

    Sandia National Laboratories has considerable experience with monochrome video cameras used in alarm assessment video systems. Most of these systems, used for perimeter protection, were designed to classify rather than identify an intruder. Monochrome cameras are adequate for that application and were selected over color cameras because of their greater sensitivity and resolution. There is a growing interest in the identification function of security video systems for both access control and insider protection. Color information is useful for identification purposes, and color camera technology is rapidly changing. Thus, Sandia National Laboratories established an ongoing program to evaluate color solid-state cameras. Phase one resulted in the publishing of a report titled, Initial Laboratory Evaluation of Color Video Cameras (SAND--91-2579).'' It gave a brief discussion of imager chips and color cameras and monitors, described the camera selection, detailed traditional test parameters and procedures, and gave the results of the evaluation of twelve cameras. In phase two six additional cameras were tested by the traditional methods and all eighteen cameras were tested by newly developed methods. This report details both the traditional and newly developed test parameters and procedures, and gives the results of both evaluations.

  12. Contact lens compliance among a group of young, university-based lens users in South India.

    Science.gov (United States)

    Noushad, Babu; Saoji, Yeshwant; Bhakat, Premjit; Thomas, Jyothi

    2012-01-01

    To investigate the rate of compliance with the soft contact lens care and maintenance procedures with a focus on contact lens wearing habits, cleaning and disinfecting procedures, and maintenance of lens care accessories in a group of young, university-based contact lens wearers Two hundred and sixteen young soft contact lens wearers with an age range of 18-22 years were selected conveniently from the student population of Manipal University, Manipal, India. After receiving informed consent from the participants, their level of compliance with contact lenses was assessed using a questionnaire. The mean (±SD) age of the participants was 21.86±2.35 years. Out of 216 subjects, only 34% of the lens users were identified to be compliant with the least level of compliance observed in the maintenance of lens care accessories. Conventional users showed significantly (p=0.001) better level of compliance compared to disposable wearers and so did the users who acquired their lenses from clinicians (p=0.001) compared to over-the-counter lens receipt. The gender (p=0.496) and years of experience in contact lens use (p=0.142) did not show any statistically significant difference in the level of compliance. This study demonstrated that non-compliance with lens care procedures among a group of young, university-based soft contact lens wearers is common. The results indicated that all subjects had some degree of non-compliance and the least level of compliance observed in the care of lens accessories.

  13. Tear film physiology and contact lens wear. II. Contact lens-tear film interaction.

    Science.gov (United States)

    Holly, F J

    1981-04-01

    The successful fitting of contact lenses requires the practitioner to take into account many properties of the specific lens type used but the practitioner must also understand patient factors including tear properties, use of appropriate solutions, procedures for lens cleaning, and efficiency of blinking. Selection of appropriate patients, selection of lens type, proper fitting, good maintenance, and training and monitoring of patients increase the probability of achieving success.

  14. The Polaroid and the Cross. Media-Reflexivity and Allegorical Figurations in Lucian Pintilie’s The Oak (1992

    Directory of Open Access Journals (Sweden)

    Sándor Katalin

    2016-09-01

    Full Text Available The paper discusses the question of media reflexivity and allegorical figuration in Lucian Pintilie’s 1992 film, The Oak. Through a fictional narrative, the film reflects on the communist period from the historical context of the post-1989 transition strongly marked by the after-effects of dictatorship and by political, social and economic instability. By incorporating a diegetic Polaroid camera and a home movie, The Oak displays a reflexive preoccupation with the mediality and the socio-cultural constructedness of the image. The figurative, allegorizing tendency of the film – manifest in the subversive recontextualization of grand narratives, iconographic codes or images of art history – also foregrounds the question of cultural mediation. I argue that by displaying the non-transparency of the cinematic image and the cultural mediatedness of the “real,” the media-reflexive and allegorical-figurative discourse of the film can be regarded as a critical historical response to the social and representational crises linked to the communist era, but at the same time it may be symptomatic of the social, cultural, political anxieties of post-1989 transition.1

  15. Placement of a crystalline lens and intraocular lens: Retinal image quality.

    Science.gov (United States)

    Siedlecki, Damian; Nowak, Jerzy; Zajac, Marek

    2006-01-01

    The influence of changes of both crystalline lens and intraocular lens (IOL) misalignment on the retinal image quality was investigated. The optical model of the eye used in investigations was the Liou-Brennan model, which is commonly considered as one of the most anatomically accurate. The original crystalline lens from this model was replaced with an IOL, made of rigid polymethylmethacrylate, in a way that recommend obligatory procedures. The modifications that were made both for crystalline lens and IOL were the longitudinal, the transversal, and the angular displacement.

  16. Restoring lens capsule integrity enhances lens regeneration in New Zealand albino rabbits and cats.

    Science.gov (United States)

    Gwon, A; Gruber, L J; Mantras, C

    1993-11-01

    In studies conducted by numerous investigators for 150 years, lenses regenerated following endocapsular lens extraction in New Zealand albino rabbits have been irregular in shape, appearing primarily doughnut-shaped as a result of lack of lens growth at the site of the anterior capsulotomy and its adhesion to the posterior capsule. In the present study, we restored the lens capsule integrity by inserting a collagen patch at the time of surgery to seal the anterior capsulotomy and to improve the shape and structure of the regenerated lenses. We then filled the capsule bag with air to prevent adhesions between the anterior and posterior capsule and maintain capsule tautness and shape. Lens regeneration was first noted as early as one to two weeks. Regenerated lens filled approximately 50% of the capsule bag at two weeks and 100% by five weeks. Subsequent growth was in the anterior-posterior direction and measured by A-scan biometry. Lens thickness increased by 0.3 mm per month. The regenerated lenses were spherical with normal cortical structure and a nuclear opacity. In conclusion, restoration of lens capsular integrity with a collagen patch following endocapsular lens extraction enhanced the shape, structure, and growth rate of the regenerated lenses. In addition, lens regeneration was shown to occur in two cats.

  17. Development of Fresnel lens for improvement of rear visibility; Shikai kojo Fresnel lens no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Iwamoto, K.; Sanada, C.; Tsukino, M. [Nissan Motor Co. Ltd., Tokyo (Japan)

    1997-10-01

    Fresnel lenses have been widely used to increase the visual field around vehicles for drivers. However, internal reflection in these lenses has been an obstacle in producing dear images. This internal glow is generated by incident light from an unexpected direction reflecting on the non-lens surface or radiating from the non-lens surface of the Fresnel lens. The cause of internal glow has been made dear combining louver film with the lens. The newly developed technology removes obstacles in producing dear images by reducing internal glow. 7 figs.

  18. Night Vision Goggles Objectives Lens Focusing Methodology

    National Research Council Canada - National Science Library

    Pinkus, Alan; Task, H. L

    2000-01-01

    ...: interpupillary distance, tilt, eye relief, height, eyepiece and objective lens focus. Currently, aircrew use a Hoffman 20/20 test unit to pre-focus their NVG objective lenses at optical infinity before boarding their aircraft...

  19. Role of Aquaporin 0 in lens biomechanics

    Energy Technology Data Exchange (ETDEWEB)

    Sindhu Kumari, S.; Gupta, Neha [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); Shiels, Alan [Washington University School of Medicine, St. Louis, MO (United States); FitzGerald, Paul G. [Cell Biology and Human Anatomy, School of Medicine, University of California, Davis, CA (United States); Menon, Anil G. [University of Cincinnati College of Medicine, Cincinnati, OH (United States); Mathias, Richard T. [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States); Varadaraj, Kulandaiappan, E-mail: kulandaiappan.varadaraj@stonybrook.edu [Physiology and Biophysics, Stony Brook University, Stony Brook, NY (United States); SUNY Eye Institute, NY (United States)

    2015-07-10

    Maintenance of proper biomechanics of the eye lens is important for its structural integrity and for the process of accommodation to focus near and far objects. Several studies have shown that specialized cytoskeletal systems such as the beaded filament (BF) and spectrin-actin networks contribute to mammalian lens biomechanics; mutations or deletion in these proteins alters lens biomechanics. Aquaporin 0 (AQP0), which constitutes ∼45% of the total membrane proteins of lens fiber cells, has been shown to function as a water channel and a structural cell-to-cell adhesion (CTCA) protein. Our recent ex vivo study on AQP0 knockout (AQP0 KO) mouse lenses showed the CTCA function of AQP0 could be crucial for establishing the refractive index gradient. However, biomechanical studies on the role of AQP0 are lacking. The present investigation used wild type (WT), AQP5 KO (AQP5{sup −/−}), AQP0 KO (heterozygous KO: AQP0{sup +/−}; homozygous KO: AQP0{sup −/−}; all in C57BL/6J) and WT-FVB/N mouse lenses to learn more about the role of fiber cell AQPs in lens biomechanics. Electron microscopic images exhibited decreases in lens fiber cell compaction and increases in extracellular space due to deletion of even one allele of AQP0. Biomechanical assay revealed that loss of one or both alleles of AQP0 caused a significant reduction in the compressive load-bearing capacity of the lenses compared to WT lenses. Conversely, loss of AQP5 did not alter the lens load-bearing ability. Compressive load-bearing at the suture area of AQP0{sup +/−} lenses showed easy separation while WT lens suture remained intact. These data from KO mouse lenses in conjunction with previous studies on lens-specific BF proteins (CP49 and filensin) suggest that AQP0 and BF proteins could act co-operatively in establishing normal lens biomechanics. We hypothesize that AQP0, with its prolific expression at the fiber cell membrane, could provide anchorage for cytoskeletal structures like BFs and

  20. Oversampled triangulation of AWARE-10 monocentric ball lens using an auto-stigmatic microscope.

    Science.gov (United States)

    Son, Hui S; Marks, Daniel L; Brady, David J; Kim, Jungsang

    2013-09-23

    In our development of multiscale, gigapixel camera architectures, there is a need for an accurate three-dimensional position alignment of large monocentric lenses relative to hemispherical dome structures. In this work we describe a method for estimating the position of the objective lens in our AWARE-10 four-gigapixel camera using the retro-reflected signal of a custom-designed auto-stigmatic microscope. We show that although the physical constraints of the system limit the numerical aperture of the microscope probe beam to around 0.016, which results in poor sensitivity in the axial direction, the lateral sensitivity is more than sufficient to verify that the position of the objective is within optical tolerances.

  1. Area x-ray detector based on a lens-coupled charge-coupled device

    International Nuclear Information System (INIS)

    Tate, Mark W.; Chamberlain, Darol; Gruner, Sol M.

    2005-01-01

    An area x-ray detector constructed using commercially available 'off-the-shelf' parts is described and its performance is characterized. The detector consists of a 1024x1024 pixel charge-coupled device (CCD) camera optically coupled to x-ray sensitive phosphor screen using a standard 35 mm camera lens. The conversion efficiency, spatial nonuniformity, spatial resolution and the detective quantum efficiency of the detector have been measured. Also shown is an example of data taken with the detector. The detector is a relatively low-cost device suitable for a wide variety of quantitative x-ray experiments where the input area need not be larger than about 70 mm across

  2. Contractual considerations in contact lens practice.

    Science.gov (United States)

    Classé, J G

    1986-03-01

    The use of forms in contact lens practice can save time, promote patient education, and reduce the opportunity for legal or economic disputes. The most commonly employed forms are those for contact lens fitting agreements, instructions for care and maintenance of lenses, prepaid service agreements, clinical investigations of investigatory lenses or solutions, and for extended wear patients. Sample forms are utilized for purposes of illustration.

  3. Evolution and the Calcite Eye Lens

    OpenAIRE

    Williams, Vernon L.

    2013-01-01

    Calcite is a uniaxial, birefringent crystal, which in its optically transparent form, has been used for animal eye lenses, the trilobite being one such animal. Because of the calcite birefringence there is a difficulty in using calcite as a lens. When the propagation direction of incoming light is not exactly on the c-axis, the mages blur. In this paper, calcite blurring is evaluated, and the non-blurring by a crystallin eye lens is compared to a calcite one.

  4. Acute lens-induced glaucomas: A review

    Directory of Open Access Journals (Sweden)

    Syed Shoeb Ahmad

    2017-02-01

    Full Text Available Lens-induced factors are important and common mechanisms causing acute elevation of intraocular pressure. While in most cases, the diagnosis and management are straight-forward, in others it is difficult and can lead to improper procedures, complications and poor visual outcomes. This review was done with the aim of studying the various types of lens-induced glaucomas, classifying them in an easy way to understand manner, their clinical features, current management and future possibilities.

  5. Acoustic lens for capacitive micromachined ultrasonic transducers

    Science.gov (United States)

    Chang, Chienliu; Firouzi, Kamyar; Park, Kwan Kyu; Sarioglu, Ali Fatih; Nikoozadeh, Amin; Yoon, Hyo-Seon; Vaithilingam, Srikant; Carver, Thomas; Khuri-Yakub, Butrus T.

    2014-08-01

    Capacitive micromachined ultrasonic transducers (CMUTs) have great potential to compete with traditional piezoelectric transducers in therapeutic ultrasound applications. In this paper we have designed, fabricated and developed an acoustic lens formed on the CMUT to mechanically focus ultrasound. The acoustic lens was designed based on the paraxial theory and made of silicone rubber for acoustic impedance matching and encapsulation. The CMUT was fabricated based on the local oxidation of silicon (LOCOS) and fusion-bonding. The fabricated CMUT was verified to behave like an electromechanical resonator in air and exhibited wideband response with a center frequency of 2.2 MHz in immersion. The fabrication for the acoustic lens contained two consecutive mold castings and directly formed on the surface of the CMUT. Applied with ac burst input voltages at the center frequency, the CMUT with the acoustic lens generated an output pressure of 1.89 MPa (peak-to-peak) at the focal point with an effective focal gain of 3.43 in immersion. Compared to the same CMUT without a lens, the CMUT with the acoustic lens demonstrated the ability to successfully focus ultrasound and provided a viable solution to the miniaturization of the multi-modality forward-looking endoscopes without electrical focusing.

  6. Acoustic lens for capacitive micromachined ultrasonic transducers

    International Nuclear Information System (INIS)

    Chang, Chienliu; Firouzi, Kamyar; Sarioglu, Ali Fatih; Nikoozadeh, Amin; Yoon, Hyo-Seon; Vaithilingam, Srikant; Carver, Thomas; Khuri-Yakub, Butrus T; Kyu Park, Kwan

    2014-01-01

    Capacitive micromachined ultrasonic transducers (CMUTs) have great potential to compete with traditional piezoelectric transducers in therapeutic ultrasound applications. In this paper we have designed, fabricated and developed an acoustic lens formed on the CMUT to mechanically focus ultrasound. The acoustic lens was designed based on the paraxial theory and made of silicone rubber for acoustic impedance matching and encapsulation. The CMUT was fabricated based on the local oxidation of silicon (LOCOS) and fusion-bonding. The fabricated CMUT was verified to behave like an electromechanical resonator in air and exhibited wideband response with a center frequency of 2.2 MHz in immersion. The fabrication for the acoustic lens contained two consecutive mold castings and directly formed on the surface of the CMUT. Applied with ac burst input voltages at the center frequency, the CMUT with the acoustic lens generated an output pressure of 1.89 MPa (peak-to-peak) at the focal point with an effective focal gain of 3.43 in immersion. Compared to the same CMUT without a lens, the CMUT with the acoustic lens demonstrated the ability to successfully focus ultrasound and provided a viable solution to the miniaturization of the multi-modality forward-looking endoscopes without electrical focusing. (paper)

  7. LENS: Science Scope and Development Stages

    Science.gov (United States)

    Vogelaar, R. Bruce

    2013-04-01

    The Low-Energy Neutrino Spectroscopy (LENS) experiment will resolve the solar metallicity question via measurement of the CNO neutrino flux, as well as test the predicted equivalence of solar luminosity as measured by photon versus neutrinos. The LENS detector uses charged-current interaction of neutrinos on Indium-115 (loaded in a scintillator, InLS) to reveal the complete solar neutrino spectrum. LENS's optically segmented 3D lattice geometry achieves precise time and spatial resolution and unprecedented background rejection and sensitivity for low-energy neutrino events. This first-of-a-kind lattice design is also suited for a range of other applications where high segmentation and large light collection are required (eg: sterile neutrinos with sources, double beta decay, and surface detection of reactor neutrinos). The physics scope, detector design, and logic driving the microLENS and miniLENS prototyping stages will be presented. The collaboration is actively running programs; building, operating, developing, and simulating these prototypes using the Kimballton Underground Research Facility (KURF). New members are welcome to the LENS Collaboration, and interested parties should contact R. Bruce Vogelaar.

  8. Human tracking over camera networks: a review

    Science.gov (United States)

    Hou, Li; Wan, Wanggen; Hwang, Jenq-Neng; Muhammad, Rizwan; Yang, Mingyang; Han, Kang

    2017-12-01

    In recent years, automated human tracking over camera networks is getting essential for video surveillance. The tasks of tracking human over camera networks are not only inherently challenging due to changing human appearance, but also have enormous potentials for a wide range of practical applications, ranging from security surveillance to retail and health care. This review paper surveys the most widely used techniques and recent advances for human tracking over camera networks. Two important functional modules for the human tracking over camera networks are addressed, including human tracking within a camera and human tracking across non-overlapping cameras. The core techniques of human tracking within a camera are discussed based on two aspects, i.e., generative trackers and discriminative trackers. The core techniques of human tracking across non-overlapping cameras are then discussed based on the aspects of human re-identification, camera-link model-based tracking and graph model-based tracking. Our survey aims to address existing problems, challenges, and future research directions based on the analyses of the current progress made toward human tracking techniques over camera networks.

  9. Image compensation for camera and lighting variability

    Science.gov (United States)

    Daley, Wayne D.; Britton, Douglas F.

    1996-12-01

    With the current trend of integrating machine vision systems in industrial manufacturing and inspection applications comes the issue of camera and illumination stabilization. Unless each application is built around a particular camera and highly controlled lighting environment, the interchangeability of cameras of fluctuations in lighting become a problem as each camera usually has a different response. An empirical approach is proposed where color tile data is acquired using the camera of interest, and a mapping is developed to some predetermined reference image using neural networks. A similar analytical approach based on a rough analysis of the imaging systems is also considered for deriving a mapping between cameras. Once a mapping has been determined, all data from one camera is mapped to correspond to the images of the other prior to performing any processing on the data. Instead of writing separate image processing algorithms for the particular image data being received, the image data is adjusted based on each particular camera and lighting situation. All that is required when swapping cameras is the new mapping for the camera being inserted. The image processing algorithms can remain the same as the input data has been adjusted appropriately. The results of utilizing this technique are presented for an inspection application.

  10. Using DSLR cameras in digital holography

    Science.gov (United States)

    Hincapié-Zuluaga, Diego; Herrera-Ramírez, Jorge; García-Sucerquia, Jorge

    2017-08-01

    In Digital Holography (DH), the size of the bidimensional image sensor to record the digital hologram, plays a key role on the performance of this imaging technique; the larger the size of the camera sensor, the better the quality of the final reconstructed image. Scientific cameras with large formats are offered in the market, but their cost and availability limit their use as a first option when implementing DH. Nowadays, DSLR cameras provide an easy-access alternative that is worthwhile to be explored. The DSLR cameras are a wide, commercial, and available option that in comparison with traditional scientific cameras, offer a much lower cost per effective pixel over a large sensing area. However, in the DSLR cameras, with their RGB pixel distribution, the sampling of information is different to the sampling in monochrome cameras usually employed in DH. This fact has implications in their performance. In this work, we discuss why DSLR cameras are not extensively used for DH, taking into account the problem reported by different authors of object replication. Simulations of DH using monochromatic and DSLR cameras are presented and a theoretical deduction for the replication problem using the Fourier theory is also shown. Experimental results of DH implementation using a DSLR camera show the replication problem.

  11. Optimising camera traps for monitoring small mammals.

    Directory of Open Access Journals (Sweden)

    Alistair S Glen

    Full Text Available Practical techniques are required to monitor invasive animals, which are often cryptic and occur at low density. Camera traps have potential for this purpose, but may have problems detecting and identifying small species. A further challenge is how to standardise the size of each camera's field of view so capture rates are comparable between different places and times. We investigated the optimal specifications for a low-cost camera trap for small mammals. The factors tested were 1 trigger speed, 2 passive infrared vs. microwave sensor, 3 white vs. infrared flash, and 4 still photographs vs. video. We also tested a new approach to standardise each camera's field of view. We compared the success rates of four camera trap designs in detecting and taking recognisable photographs of captive stoats (Mustelaerminea, feral cats (Felis catus and hedgehogs (Erinaceuseuropaeus. Trigger speeds of 0.2-2.1 s captured photographs of all three target species unless the animal was running at high speed. The camera with a microwave sensor was prone to false triggers, and often failed to trigger when an animal moved in front of it. A white flash produced photographs that were more readily identified to species than those obtained under infrared light. However, a white flash may be more likely to frighten target animals, potentially affecting detection probabilities. Video footage achieved similar success rates to still cameras but required more processing time and computer memory. Placing two camera traps side by side achieved a higher success rate than using a single camera. Camera traps show considerable promise for monitoring invasive mammal control operations. Further research should address how best to standardise the size of each camera's field of view, maximise the probability that an animal encountering a camera trap will be detected, and eliminate visible or audible cues emitted by camera traps.

  12. Optimising camera traps for monitoring small mammals.

    Science.gov (United States)

    Glen, Alistair S; Cockburn, Stuart; Nichols, Margaret; Ekanayake, Jagath; Warburton, Bruce

    2013-01-01

    Practical techniques are required to monitor invasive animals, which are often cryptic and occur at low density. Camera traps have potential for this purpose, but may have problems detecting and identifying small species. A further challenge is how to standardise the size of each camera's field of view so capture rates are comparable between different places and times. We investigated the optimal specifications for a low-cost camera trap for small mammals. The factors tested were 1) trigger speed, 2) passive infrared vs. microwave sensor, 3) white vs. infrared flash, and 4) still photographs vs. video. We also tested a new approach to standardise each camera's field of view. We compared the success rates of four camera trap designs in detecting and taking recognisable photographs of captive stoats (Mustelaerminea), feral cats (Felis catus) and hedgehogs (Erinaceuseuropaeus). Trigger speeds of 0.2-2.1 s captured photographs of all three target species unless the animal was running at high speed. The camera with a microwave sensor was prone to false triggers, and often failed to trigger when an animal moved in front of it. A white flash produced photographs that were more readily identified to species than those obtained under infrared light. However, a white flash may be more likely to frighten target animals, potentially affecting detection probabilities. Video footage achieved similar success rates to still cameras but required more processing time and computer memory. Placing two camera traps side by side achieved a higher success rate than using a single camera. Camera traps show considerable promise for monitoring invasive mammal control operations. Further research should address how best to standardise the size of each camera's field of view, maximise the probability that an animal encountering a camera trap will be detected, and eliminate visible or audible cues emitted by camera traps.

  13. [Human physiology: images and practices of the reflex].

    Science.gov (United States)

    Wübben, Yvonne

    2010-01-01

    The essay examines the function of visualizations and practices in the formation of the reflex concept from Thomas Willis to Marshall Hall. It focuses on the specific form of reflex knowledge that images and practices can contain. In addition, the essay argues that it is through visual representations and experimental practices that technical knowledge is transferred to the field of human reflex physiology. When using technical metaphors in human physiology authors often seem to feel obliged to draw distinctions between humans, machines and animals. On closer scrutiny, these distinctions sometimes fail to establish firm borders between the human and the technical.

  14. Flexion Reflex Can Interrupt and Reset the Swimming Rhythm.

    Science.gov (United States)

    Elson, Matthew S; Berkowitz, Ari

    2016-03-02

    The spinal cord can generate the hip flexor nerve activity underlying leg withdrawal (flexion reflex) and the rhythmic, alternating hip flexor and extensor activities underlying locomotion and scratching, even in the absence of brain inputs and movement-related sensory feedback. It has been hypothesized that a common set of spinal interneurons mediates flexion reflex and the flexion components of locomotion and scratching. Leg cutaneous stimuli that evoke flexion reflex can alter the timing of (i.e., reset) cat walking and turtle scratching rhythms; in addition, reflex responses to leg cutaneous stimuli can be modified during cat and human walking and turtle scratching. Both of these effects depend on the phase (flexion or extension) of the rhythm in which the stimuli occur. However, similar interactions between leg flexion reflex and swimming have not been reported. We show here that a tap to the foot interrupted and reset the rhythm of forward swimming in spinal, immobilized turtles if the tap occurred during the swim hip extensor phase. In addition, the hip flexor nerve response to an electrical foot stimulus was reduced or eliminated during the swim hip extensor phase. These two phase-dependent effects of flexion reflex on the swim rhythm and vice versa together demonstrate that the flexion reflex spinal circuit shares key components with or has strong interactions with the swimming spinal network, as has been shown previously for cat walking and turtle scratching. Therefore, leg flexion reflex circuits likely share key spinal interneurons with locomotion and scratching networks across limbed vertebrates generally. The spinal cord can generate leg withdrawal (flexion reflex), locomotion, and scratching in limbed vertebrates. It has been hypothesized that there is a common set of spinal cord neurons that produce hip flexion during flexion reflex, locomotion, and scratching based on evidence from studies of cat and human walking and turtle scratching. We show

  15. Augmented reality glass-free three-dimensional display with the stereo camera

    Science.gov (United States)

    Pang, Bo; Sang, Xinzhu; Chen, Duo; Xing, Shujun; Yu, Xunbo; Yan, Binbin; Wang, Kuiru; Yu, Chongxiu

    2017-10-01

    An improved method for Augmented Reality (AR) glass-free three-dimensional (3D) display based on stereo camera used for presenting parallax contents from different angle with lenticular lens array is proposed. Compared with the previous implementation method of AR techniques based on two-dimensional (2D) panel display with only one viewpoint, the proposed method can realize glass-free 3D display of virtual objects and real scene with 32 virtual viewpoints. Accordingly, viewers can get abundant 3D stereo information from different viewing angles based on binocular parallax. Experimental results show that this improved method based on stereo camera can realize AR glass-free 3D display, and both of virtual objects and real scene have realistic and obvious stereo performance.

  16. Function and Evolutionary Origin of Unicellular Camera-Type Eye Structure

    KAUST Repository

    Hayakawa, Shiho

    2015-03-03

    The ocelloid is an extraordinary eyespot organelle found only in the dinoflagellate family Warnowiaceae. It contains retina- and lens-like structures called the retinal body and the hyalosome. The ocelloid has been an evolutionary enigma because of its remarkable resemblance to the multicellular camera-type eye. To determine if the ocelloid is functionally photoreceptive, we investigated the warnowiid dinoflagellate Erythropsidinium. Here, we show that the morphology of the retinal body changed depending on different illumination conditions and the hyalosome manifests the refractile nature. Identifying a rhodopsin gene fragment in Erythropsidinium ESTs that is expressed in the retinal body by in situ hybridization, we also show that ocelloids are actually light sensitive photoreceptors. The rhodopsin gene identified is most closely related to bacterial rhodopsins. Taken together, we suggest that the ocelloid is an intracellular camera-type eye, which might be originated from endosymbiotic origin. © 2015 Hayakawa et al.

  17. Sharing of secondary electrons by in-lens and out-lens detector in low-voltage scanning electron microscope equipped with immersion lens.

    Science.gov (United States)

    Kumagai, Kazuhiro; Sekiguchi, Takashi

    2009-03-01

    To understand secondary electron (SE) image formation with in-lens and out-lens detector in low-voltage scanning electron microscopy (LV-SEM), we have evaluated SE signals of an in-lens and an out-lens detector in LV-SEM. From the energy distribution spectra of SEs with various boosting voltages of the immersion lens system, we revealed that the electrostatic field of the immersion lens mainly collects electrons with energy lower than 40eV, acting as a low-pass filter. This effect is also observed as a contrast change in LV-SEM images taken by in-lens and out-lens detectors.

  18. Leg muscle reflexes mediated by cutaneous A-beta fibres are normal during gait in reflex sympathetic dystrophy.

    Science.gov (United States)

    van der Laan, L; Boks, L M; van Wezel, B M; Goris, R J; Duysens, J E

    2000-04-01

    Reflex sympathetic dystrophy (RSD) is, from the onset, characterized by various neurological deficits such as an alteration of sensation and a decrease in muscle strength. We investigated if afferent A-beta fibre-mediated reflexes are changed in lower extremities affected by acute RSD. The involvement of these fibres was determined by analyzing reflex responses from the tibialis anterior (TA) and biceps femoris (BF) muscles after electrical stimulation of the sural nerve. The reflexes were studied during walking on a treadmill to investigate whether the abnormalities in gait of the patients were related either to abnormal amplitudes or deficient phase-dependent modulation of reflexes. In 5 patients with acute RSD of the leg and 5 healthy volunteers these reflex responses were determined during the early and late swing phase of the step cycle. No significant difference was found between the RSD and the volunteers. During early swing the mean amplitude of the facilitatory P2 responses in BF and TA increased as a function of stimulus intensity (1.5, 2 and 2.5 times the perception threshold) in both groups. At end swing the same stimuli induced suppressive responses in TA. This phase-dependent reflex reversal from facilitation in early swing to suppression in late swing occurred equally in both groups. In the acute phase of RSD of the lower extremity there is no evidence for abnormal A-beta fibre-mediated reflexes or for defective regulation of such reflexes. This finding has implications for both the theory on RSD pathophysiology and RSD models, which are based on abnormal functioning of A-beta fibres.

  19. Cluster eye camera using microlenses on parabolic surface

    Science.gov (United States)

    Shen, Hui-Kai; Su, Guo-Dung J.

    2013-10-01

    There are two main types of imaging systems that exist in nature: the single aperture eye and the compound eye. Usually, cameras and most of artificial imaging systems are similar to the single aperture eye. But compound lenses can be more compact than single lenses. Our design is based on insect compound eyes, which also have a wide field of view (FOV). With the rise of micro-optical techniques, fabricating compound lenses has become easier. The simplest form of a curved microlens array is a parabolic surface. In this paper, we proposed a multi-channel imaging system, which combines the principles of the insect compound eye and the human eye. The optical system enables the reduction of track length of the imaging optics to achieve miniaturization. With the aid of optical engineering software ZEMAX, the multi-channel structure is simulated by a curved microlens array, and we use a Hypergon lens as the main lens to simulate the human eye, which can achieve the purpose of the wide FOV. With this architecture, each microlens of a microlens array transmits a segment of the overall FOV. The partial images that are separately recorded in different channels are stitched together to form the final image of the whole FOV by software processing. A 2.74 mm thin imaging system with 59 channels and 90° FOV is optimized using ZEMAX sequential ray tracing software on a 6.16 mm × 4.62 mm image plane. Finally, we will discuss the simulation results of this system and compare it with the optical cluster eye system and a mobile phone patent.

  20. New camera-based microswitch technology to monitor small head and mouth responses of children with multiple disabilities.

    Science.gov (United States)

    Lancioni, Giulio E; Bellini, Domenico; Oliva, Doretta; Singh, Nirbhay N; O'Reilly, Mark F; Green, Vanessa A; Furniss, Fred

    2014-06-01

    Assessing a new camera-based microswitch technology, which did not require the use of color marks on the participants' face. Two children with extensive multiple disabilities participated. The responses selected for them consisted of small, lateral head movements and mouth closing or opening. The intervention was carried out according to a multiple probe design across responses. The technology involved a computer with a CPU using a 2-GHz clock, a USB video camera with a 16-mm lens, a USB cable connecting the camera and the computer, and a special software program written in ISO C++ language. The new technology was satisfactorily used with both children. Large increases in their responding were observed during the intervention periods (i.e. when the responses were followed by preferred stimulation). The new technology may be an important resource for persons with multiple disabilities and minimal motor behavior.

  1. Photogrammetric Applications of Immersive Video Cameras

    OpenAIRE

    Kwiatek, K.; Tokarczyk, R.

    2014-01-01

    The paper investigates immersive videography and its application in close-range photogrammetry. Immersive video involves the capture of a live-action scene that presents a 360° field of view. It is recorded simultaneously by multiple cameras or microlenses, where the principal point of each camera is offset from the rotating axis of the device. This issue causes problems when stitching together individual frames of video separated from particular cameras, however there are ways to ov...

  2. Plasticity of the cervico-ocular reflex in health and Disease

    NARCIS (Netherlands)

    W.P.A. Kelders (Willem)

    2006-01-01

    textabstractThe cervico-ocular reflex (COR) is an ocular stabilization reflex that is elicited by rotation of the neck. It works in conjunction with the vestibulo-ocular reflex (VOR) and the optokinetic reflex (OKR) in order to prevent visual slip over the retina due to self motion. The VOR

  3. Compensatory increase of the cervico-ocular reflex with age in healthy humans.

    NARCIS (Netherlands)

    W.P.A. Kelders (Willem); G.J. Kleinrensink (Gert Jan); J.N. van der Geest (Jos); L. Feenstra (Louw); C.I. de Zeeuw (Chris); M.A. Frens (Maarten)

    2003-01-01

    textabstractThe cervico-ocular reflex (COR) is an ocular stabilization reflex that is elicited by rotation of the neck. It works in conjunction with the vestibulo-ocular reflex (VOR) and the optokinetic reflex (OKR) in order to prevent visual slip over the retina due to

  4. Approximations to camera sensor noise

    Science.gov (United States)

    Jin, Xiaodan; Hirakawa, Keigo

    2013-02-01

    Noise is present in all image sensor data. Poisson distribution is said to model the stochastic nature of the photon arrival process, while it is common to approximate readout/thermal noise by additive white Gaussian noise (AWGN). Other sources of signal-dependent noise such as Fano and quantization also contribute to the overall noise profile. Question remains, however, about how best to model the combined sensor noise. Though additive Gaussian noise with signal-dependent noise variance (SD-AWGN) and Poisson corruption are two widely used models to approximate the actual sensor noise distribution, the justification given to these types of models are based on limited evidence. The goal of this paper is to provide a more comprehensive characterization of random noise. We concluded by presenting concrete evidence that Poisson model is a better approximation to real camera model than SD-AWGN. We suggest further modification to Poisson that may improve the noise model.

  5. Acanthamoeba keratitis and contact lens wear.

    Science.gov (United States)

    Lindsay, Richard G; Watters, Grant; Johnson, Richard; Ormonde, Susan E; Snibson, Grant R

    2007-09-01

    Acanthamoeba keratitis is a rare but serious complication of contact lens wear that may cause severe visual loss. The clinical picture is usually characterised by severe pain, sometimes disproportionate to the signs, with an early superficial keratitis that is often misdiagnosed as herpes simplex virus (HSV) keratitis. Advanced stages of the infection are usually characterised by central corneal epithelial loss and marked stromal opacification with subsequent loss of vision. In this paper, six cases of contact lens-related Acanthamoeba keratitis that occurred in Australia and New Zealand over a three-year period are described. Three of the patients were disposable soft lens wearers, two were hybrid lens wearers and one was a rigid gas permeable lens wearer. For all six cases, the risk factors for Acanthamoeba keratitis were contact lens wear with inappropriate or ineffective lens maintenance and exposure of the contact lenses to tap or other sources of water. All six patients responded well to medical therapy that involved topical use of appropriate therapeutic agents, most commonly polyhexamethylene biguanide and propamidine isethionate, although two of the patients also subsequently underwent deep lamellar keratoplasty due to residual corneal surface irregularity and stromal scarring. Despite the significant advances that have been made in the medical therapy of Acanthamoeba keratitis over the past 10 years, prevention remains the best treatment and patients who wear contact lenses must be thoroughly educated about the proper use and care of the lenses. In particular, exposure of the contact lenses to tap water or other sources of water should be avoided.

  6. Interindividual differences in H reflex modulation during normal walking

    DEFF Research Database (Denmark)

    Simonsen, Erik B; Dyhre-Poulsen, Poul; Alkjaer, T

    2002-01-01

    Based on previous studies, at least two different types of soleus Hoffmann (H) reflex modulation were likely to be found during normal human walking. Accordingly, the aim of the present study was to identify different patterns of modulation of the soleus H reflex and to examine whether...... or not subjects with different H reflex modulation would exhibit different walking mechanics and different EMG activity. Fifteen subjects walked across two force platforms at 4.5 km/h (+/-10%) while the movements were recorded on video. The soleus H reflex and EMG activity were recorded separately during...... treadmill walking at 4.5 km/h. Using a two-dimensional analysis joint angles, angular velocities, accelerations, linear velocities and accelerations were calculated, and net joint moments about the ankle, knee and hip joint were computed by inverse dynamics from the video and force plate data. Six subjects...

  7. Non-reflexive Logical Foundation for Quantum Mechanics

    Science.gov (United States)

    da Costa, N. C. A.; de Ronde, C.

    2014-12-01

    On the one hand, non-reflexive logics are logics in which the principle of identity does not hold in general. On the other hand, quantum mechanics has difficulties regarding the interpretation of `particles' and their identity, also known in the literature as `the problem of indistinguishable particles'. In this article, we will argue that non-reflexive logics can be a useful tool to account for such quantum indistinguishability. In particular, we will provide a particular non-reflexive logic that can help us to analyze and discuss this problem. From a more general physical perspective, we will also analyze the limits imposed by the orthodox quantum formalism to consider the existence of indistinguishable particles in the first place, and argue that non-reflexive logics can also help us to think beyond the limits of classical identity.

  8. Pseudodystrophy. A conversion disorder mimicking reflex sympathetic dystrophy.

    Science.gov (United States)

    Driessens, M; Blockx, P; Geuens, G; Dijs, H; Verheyen, G; Stassijns, G

    2002-10-01

    The authors suggest some criteria by which pseudodystrophy and reflex sympathetic dystrophy, although sharing some similar clinical features, can be distinguished as two different conditions, each requiring its own approach and management. The most important distinction is found on bone scintigraphy. In reflex sympathetic dystrophy the bone scan shows a typical increased tracer uptake (at least during stages I and II); in pseudodystrophy there is a normal or decreased tracer uptake in the affected region. Moreover the vascularization is increased in reflex sympathetic dystrophy stage I, whereas in pseudodystrophy hypovascularization is found from the beginning. The clinical features, as well as the results of technical investigations, psychological evaluation and treatment of 4 patients with pseudodystrophy are presented. The importance of distinguishing this condition from reflex sympathetic dystrophy is stressed.

  9. Streak camera recording of interferometer fringes

    International Nuclear Information System (INIS)

    Parker, N.L.; Chau, H.H.

    1977-01-01

    The use of an electronic high-speed camera in the streaking mode to record interference fringe motion from a velocity interferometer is discussed. Advantages of this method over the photomultiplier tube-oscilloscope approach are delineated. Performance testing and data for the electronic streak camera are discussed. The velocity profile of a mylar flyer accelerated by an electrically exploded bridge, and the jump-off velocity of metal targets struck by these mylar flyers are measured in the camera tests. Advantages of the streak camera include portability, low cost, ease of operation and maintenance, simplified interferometer optics, and rapid data analysis

  10. Decision about buying a gamma camera

    International Nuclear Information System (INIS)

    Ganatra, R.D.

    1992-01-01

    A large part of the referral to a nuclear medicine department is usually for imaging studies. Sooner or later, the nuclear medicine specialist will be called upon to make a decision about when and what type of gamma camera to buy. There is no longer an option of choosing between a rectilinear scanner and a gamma camera as the former is virtually out of the market. The decision that one has to make is when to invest in a gamma camera, and then on what basis to select the gamma camera

  11. Properties of the cathode lens combined with a focusing magnetic/immersion-magnetic lens

    International Nuclear Information System (INIS)

    Konvalina, I.; Muellerova, I.

    2011-01-01

    The cathode lens is an electron optical element in an emission electron microscope accelerating electrons from the sample, which serves as a source for a beam of electrons. Special application consists in using the cathode lens first for retardation of an illuminating electron beam and then for acceleration of reflected as well as secondary electrons, made in the directly imaging low energy electron microscope or in its scanning version discussed here. In order to form a real image, the cathode lens has to be combined with a focusing magnetic lens or a focusing immersion-magnetic lens, as used for objective lenses of some commercial scanning electron microscopes. These two alternatives are compared with regards to their optical properties, in particular with respect to predicted aberration coefficients and the spot size, as well as the optimum angular aperture of the primary beam. The important role of the final aperture size on the image resolution is also presented.

  12. Sympathetic skin responses in reflex sympathetic dystrophy.

    Science.gov (United States)

    Bolel, K; Hizmetli, S; Akyüz, A

    2006-07-01

    This study was performed to determine the utility of sympathetic skin response (SSR) in evaluating the sympathetic function and to follow up the effects of sympathetic blockade in reflex sympathetic dystrophy (RSD). Thirty patients having RSD with upper extremity involvement were randomly divided into two groups. Besides medical therapy and exercise, physical therapy agents were applied to both the groups. In addition to this treatment protocol, stellar ganglion blockade was done by diadynamic current in Group II. The normal sides of the patients were used for the control group. SSRs were measured in all the patients before and after the therapy. The amplitude was found to be increased and the latency was found to be decreased in the affected side in both the groups before the therapy. After the therapy, the amplitude was decreased and latency was increased in both the groups. But, the differences in amplitude (P = 0.001) and latency (P = 0.002) before and after the therapy were significantly higher in Group II. (Before the treatment, SSRs were significantly different between the normal and the affected sides in both the groups. The observed change in SSRs after the treatment was higher in Group II.) It was concluded that, SSR can be a useful and noninvasive method in diagnosing the sympathetic dysfunction in RSD and can be used for evaluating the response to sympathetic blockade and other treatment modalities.

  13. Reflex sympathetic dystrophy syndrome and neuromediators.

    Science.gov (United States)

    Pham, Thao; Lafforgue, Pierre

    2003-02-01

    Concepts related to the pathophysiology of reflex sympathetic dystrophy syndrome (RSDS) are changing. Although sympathetic influences are still viewed as the most likely mechanism underlying the development and/or perpetuation of RSDS, these influences are no longer ascribed to an increase in sympathetic tone. Rather, the most likely mechanism may be increased sensitivity to catecholamines due to sympathetic denervation with an increase in the number and/or sensitivity of peripheral axonal adrenoceptors. Several other pathophysiological mechanisms have been suggested, including neurogenic inflammation with the release of neuropeptides by primary nociceptive afferents and sympathetic efferents. These neuromediators, particularly substance P, calcitonin gene-related peptide, and neuropeptide Y (NPY), may play a pivotal role in the genesis of pain in RSDS. They induce an inflammatory response (cutaneous erythema and edema) and lower the pain threshold. Neurogenic inflammation at the site of the lesion with neuromediator accumulation or depletion probably contributes to the pathophysiology of RSDS. However, no single neuromediator has been proved responsible, and other hypotheses continue to arouse interest.

  14. Blink reflexes in patients with atypical odontalgia.

    Science.gov (United States)

    Baad-Hansen, Lene; List, Thomas; Jensen, Troels Staehelin; Leijon, Göran; Svensson, Peter

    2005-01-01

    To use the human blink reflex (BR) to explore possible neuropathic pain mechanisms in patients with atypical odontalgia (AO). In 13 AO patients, the BR was elicited using a concentric electrode and recorded bilaterally with surface electromyographic (EMG) electrodes on both orbicularis oculi muscles. Electrical stimuli were applied to the skin above branches of the V1, V2, and V3 nerves and to the V branch contralateral to the painful branch. Sensory and pain thresholds were determined. The BR examination of the painful V branch was repeated during a capsaicin pain-provocation test. The data were analyzed with nonparametric statistics. The BR responses (R2 and R3) evoked by stimulation of V3 were significantly smaller than the BR responses evoked by stimulation of V1 and V2 (P .569), and the BR (R2 and R3) was not significantly modulated by experimental pain (P > .080). The sensory thresholds were significantly lower on the painful side compared to the nonpainful side (P = .014). The pain thresholds were not different between sides (P > .910). No major differences between the V nociceptive pathways on the right and left sides were found in a relatively small group of AO patients. Future studies that compare BRs in AO patients and healthy volunteers are needed to provide further knowledge on the pain mechanisms in AO.

  15. Cough reflex hypersensitivity: A role for neurotrophins.

    Science.gov (United States)

    El-Hashim, Ahmed Z; Jaffal, Sahar M

    2017-03-01

    Cough is one of the most common complaints for which sufferers seek medical assistance. However, currently available drugs are not very effective in treating cough, particularly that which follows an upper respiratory tract infection. Nonetheless, there has been a significant increase in our understanding of the mechanisms and pathways of the defensive cough as well as the hypersensitive/pathophysiological cough, both at airway and central nervous system (CNS) levels. Numerous molecules and signaling pathways have been identified as potential targets for antitussive drugs, including neurotrophins (NTs). NTs belong to a family of trophic factors and are critical for the development and maintenance of neurons in the central and peripheral nervous system including sympathetic efferents, sensory neuron afferents, and immune cells. Nerve growth factor (NGF) was the first member of the NT family to be discovered, with wide ranging actions associated with synapse formation, survival, proliferation, apoptosis, axonal and dendritic outgrowth, expression and activity of functionally important proteins such as ion channels, receptors, and neurotransmitters. In addition, NGF has been implicated in several disease states particularly neuropathic pain and most recently in the sensitization of the cough reflex. This review will briefly address the peripheral and central sensitization mechanisms of airway neurons and will then focus on NGF signaling and its role in cough hypersensitivity.

  16. Imaging with depth extension: where are the limits in fixed- focus cameras?

    Science.gov (United States)

    Bakin, Dmitry; Keelan, Brian

    2008-08-01

    The integration of novel optics designs, miniature CMOS sensors, and powerful digital processing into a single imaging module package is driving progress in handset camera systems in terms of performance, size (thinness) and cost. The miniature cameras incorporating high resolution sensors and fixed-focus Extended Depth of Field (EDOF) optics allow close-range reading of printed material (barcode patterns, business cards), while providing high quality imaging in more traditional applications. These cameras incorporate modified optics and digital processing to recover the soft-focus images and restore sharpness over a wide range of object distances. The effects a variety of parameters of the imaging module on the EDOF range were analyzed for a family of high resolution CMOS modules. The parameters include various optical properties of the imaging lens, and the characteristics of the sensor. The extension factors for the EDOF imaging module were defined in terms of an improved absolute resolution in object space while maintaining focus at infinity. This definition was applied for the purpose of identifying the minimally resolvable object details in mobile cameras with bar-code reading feature.

  17. Motionless active depth from defocus system using smart optics for camera autofocus applications

    Science.gov (United States)

    Amin, M. Junaid; Riza, Nabeel A.

    2016-04-01

    This paper describes a motionless active Depth from Defocus (DFD) system design suited for long working range camera autofocus applications. The design consists of an active illumination module that projects a scene illuminating coherent conditioned optical radiation pattern which maintains its sharpness over multiple axial distances allowing an increased DFD working distance range. The imager module of the system responsible for the actual DFD operation deploys an electronically controlled variable focus lens (ECVFL) as a smart optic to enable a motionless imager design capable of effective DFD operation. An experimental demonstration is conducted in the laboratory which compares the effectiveness of the coherent conditioned radiation module versus a conventional incoherent active light source, and demonstrates the applicability of the presented motionless DFD imager design. The fast response and no-moving-parts features of the DFD imager design are especially suited for camera scenarios where mechanical motion of lenses to achieve autofocus action is challenging, for example, in the tiny camera housings in smartphones and tablets. Applications for the proposed system include autofocus in modern day digital cameras.

  18. Benchmarking of depth of field for large out-of-plane deformations with single camera digital image correlation

    Science.gov (United States)

    Van Mieghem, Bart; Ivens, Jan; Van Bael, Albert

    2017-04-01

    A problem that arises when performing stereo digital image correlation in applications with large out-of-plane displacements is that the images may become unfocused. This unfocusing could result in correlation instabilities or inaccuracies. When performing DIC measurements and expecting large out-of-plane displacements researchers either trust on their experience or use the equations from photography to estimate the parameters affecting the depth of field (DOF) of the camera. A limitation of the latter approach is that the definition of sharpness is a human defined parameter and that it does not reflect the performance of the digital image correlation system. To get a more representative DOF value for DIC applications, a standardised testing method is presented here, making use of real camera and lens combinations as well as actual image correlation results. The method is based on experimental single camera DIC measurements of a backwards moving target. Correlation results from focused and unfocused images are compared and a threshold value defines whether or not the correlation results are acceptable even if the images are (slightly) unfocused. By following the proposed approach, the complete DOF of a specific camera/lens combination as function of the aperture setting and distance from the camera to the target can be defined. The comparison between the theoretical and the experimental DOF results shows that the achievable DOF for DIC applications is larger than what theoretical calculations predict. Practically this means that the cameras can be positioned closer to the target than what is expected from the theoretical approach. This leads to a gain in resolution and measurement accuracy.

  19. Mechanical Characteristics of Reflex Durign Upright Posture in Paralyzed Subjects

    Science.gov (United States)

    Kim, Yongchul; Youm, Youngil; Lee, Bumsuk; Kim, Youngho; Choi, Hyeonki

    The characteristics of flexor reflexes have been investigated in the previous studies with human subjects who were seated or supine position. However, researchers did not describe how the spinal circuits are used in different hip angles for paralyzed subjects, such as the standing position with walker or cane. In upright posture the compatibility between a flexor reflex of leg and body balance is a special problem for lower limb injured subjects. Therefore, the purpose of this study was to investigate the effects of hip angle change on the flexor reflex evoked in standing paralyzed subjects supported by walker. In this study, six spinal cord injured and four stroke subjects were recruited through the inpatient physical therapy clinics of Korea national rehabilitation hospital. A single axis electronic goniometer was mounted on the lateral side of the hip joint of the impaired limb to record movements in the sagittal plane at this joint. The electronic goniometer was connected to a data acquisition system, through amplifiers to a computer. Since subject' posture influenced characteristics of the flexion reflex response, the subjects were supported in an upright posture by the help of parallelogram walder. Two series of tests were performed on each leg. The first series of the tests investigated the influence of hip angle during stationary standing posture on flexion reflex response. The hip angle was adjusted by the foot plate. The second examined the effect of the voluntary action of subject on swing motion during the gait. The electrically induced flexion reflex simultaneously produced the flexion of the hip, knee and dorsiflexion of the ankle enabling the swing phase of walking. Form the experimental results we observed that the reflex response of hip joint was largerwith the hip in the extended position than in the flexed position during standing posture. Under voluntary movement on flexion reflex during gaint, the peak hip angle induced by stimulation was

  20. Reflexive Pronouns in Dagbani Samuel Alhassan Issah1 Abstract ...

    African Journals Online (AJOL)

    between a reflexive and its antecedent is accounted for using c-command. Haegeman (1994:212) claims that a node A c-commands a node B if (1) A does not dominate B; (2) B does not dominate A; and ..... reflexive o-maŋa “himself” has the subject of the embedded clause Abu as its antecedent. These two arguments, Abu ...

  1. Intranasal Midazolam May Prevent Gagging Reflex: a Case Report

    OpenAIRE

    Malkoc, Meral Arslan; Demir, Necla; Ileri, Zehra; Erdur, Aybuke; Apiliogullari, Seza

    2013-01-01

    ABSTRACT Background Gagging can become a conditioned response that makes dental treatment difficult or impossible for both the individual and the dentist. The aim of this study is to report a 50 year old female and two children (15 and 11 years old) with exaggerated gag reflex referred to Faculty of Dentistry of Selçuk University. Methods During obtaining records, taking impression procedure was elicited the patients’ hypersensitive gagging reflex. Therefore, it was decided to administer intr...

  2. [Reflexive education in post-modernity: a bibliographic review].

    Science.gov (United States)

    Gomes, Jomara Brandini; Casagrande, Lisete Diniz Ribas

    2002-01-01

    This is a bibliographical review that aimed at considering teaching at the actual historical moment, denominated post-modernity, and that has resulted in a pragmatic change in all levels of human being understanding. Thus, authors rescued and presented the presuppositions for a post-modern education, emphasizing among them the reflexive education proposed by Donald A. Shön, that is based on practical learning centered in "reflexion-in-action", as an alternative for the formation of a reflexive professional.

  3. Lens exposure during brain scans using multidetector row CT scanners: methods for estimation of lens dose.

    Science.gov (United States)

    Suzuki, S; Furui, S; Ishitake, T; Abe, T; Machida, H; Takei, R; Ibukuro, K; Watanabe, A; Kidouchi, T; Nakano, Y

    2010-05-01

    Some recent studies on radiation lens injuries have indicated much lower dose thresholds than specified by the current radiation protection guidelines. The purpose of this research was to measure the lens dose during brain CT scans with multidetector row CT and to assess methods for estimating the lens dose. With 8 types of multidetector row CT scanners, both axial and helical scans were obtained for the head part of a human-shaped phantom by using normal clinical settings with the orbitomeatal line as the baseline. We measured the doses on both eyelids by using an RPLGD during whole-brain scans including the orbit with the starting point at the level of the inferior orbital rim. To assess the effect of the starting points on the lens doses, we measured the lens doses by using 2 other starting points for scanning (the orbitomeatal line and the superior orbital rim). The CTDIvols and the lens doses during whole-brain CT including the orbit were 50.9-113.3 mGy and 42.6-103.5 mGy, respectively. The ratios of lens dose to CTDIvol were 80.6%-103.4%. The lens doses decreased as the starting points were set more superiorly. The lens doses during scans from the superior orbital rim were 11.8%-20.9% of the doses during the scans from the inferior orbital rim. CTDIvol can be used to estimate the lens dose during whole-brain CT when the orbit is included in the scanning range.

  4. Nuclear Radiation Degradation Study on HD Camera Based on CMOS Image Sensor at Different Dose Rates.

    Science.gov (United States)

    Wang, Congzheng; Hu, Song; Gao, Chunming; Feng, Chang

    2018-02-08

    In this work, we irradiated a high-definition (HD) industrial camera based on a commercial-off-the-shelf (COTS) CMOS image sensor (CIS) with Cobalt-60 gamma-rays. All components of the camera under test were fabricated without radiation hardening, except for the lens. The irradiation experiments of the HD camera under biased conditions were carried out at 1.0, 10.0, 20.0, 50.0 and 100.0 Gy/h. During the experiment, we found that the tested camera showed a remarkable degradation after irradiation and differed in the dose rates. With the increase of dose rate, the same target images become brighter. Under the same dose rate, the radiation effect in bright area is lower than that in dark area. Under different dose rates, the higher the dose rate is, the worse the radiation effect will be in both bright and dark areas. And the standard deviations of bright and dark areas become greater. Furthermore, through the progressive degradation analysis of the captured image, experimental results demonstrate that the attenuation of signal to noise ratio (SNR) versus radiation time is not obvious at the same dose rate, and the degradation is more and more serious with increasing dose rate. Additionally, the decrease rate of SNR at 20.0, 50.0 and 100.0 Gy/h is far greater than that at 1.0 and 10.0 Gy/h. Even so, we confirm that the HD industrial camera is still working at 10.0 Gy/h during the 8 h of measurements, with a moderate decrease of the SNR (5 dB). The work is valuable and can provide suggestion for camera users in the radiation field.

  5. Nuclear Radiation Degradation Study on HD Camera Based on CMOS Image Sensor at Different Dose Rates

    Directory of Open Access Journals (Sweden)

    Congzheng Wang

    2018-02-01

    Full Text Available In this work, we irradiated a high-definition (HD industrial camera based on a commercial-off-the-shelf (COTS CMOS image sensor (CIS with Cobalt-60 gamma-rays. All components of the camera under test were fabricated without radiation hardening, except for the lens. The irradiation experiments of the HD camera under biased conditions were carried out at 1.0, 10.0, 20.0, 50.0 and 100.0 Gy/h. During the experiment, we found that the tested camera showed a remarkable degradation after irradiation and differed in the dose rates. With the increase of dose rate, the same target images become brighter. Under the same dose rate, the radiation effect in bright area is lower than that in dark area. Under different dose rates, the higher the dose rate is, the worse the radiation effect will be in both bright and dark areas. And the standard deviations of bright and dark areas become greater. Furthermore, through the progressive degradation analysis of the captured image, experimental results demonstrate that the attenuation of signal to noise ratio (SNR versus radiation time is not obvious at the same dose rate, and the degradation is more and more serious with increasing dose rate. Additionally, the decrease rate of SNR at 20.0, 50.0 and 100.0 Gy/h is far greater than that at 1.0 and 10.0 Gy/h. Even so, we confirm that the HD industrial camera is still working at 10.0 Gy/h during the 8 h of measurements, with a moderate decrease of the SNR (5 dB. The work is valuable and can provide suggestion for camera users in the radiation field.

  6. Avian reflex and electroencephalogram responses in different states of consciousness.

    Science.gov (United States)

    Sandercock, Dale A; Auckburally, Adam; Flaherty, Derek; Sandilands, Victoria; McKeegan, Dorothy E F

    2014-06-22

    Defining states of clinical consciousness in animals is important in veterinary anaesthesia and in studies of euthanasia and welfare assessment at slaughter. The aim of this study was to validate readily observable reflex responses in relation to different conscious states, as confirmed by EEG analysis, in two species of birds under laboratory conditions (35-week-old layer hens (n=12) and 11-week-old turkeys (n=10)). We evaluated clinical reflexes and characterised electroencephalograph (EEG) activity (as a measure of brain function) using spectral analyses in four different clinical states of consciousness: conscious (fully awake), semi-conscious (sedated), unconscious-optimal (general anaesthesia), unconscious-sub optimal (deep hypnotic state), as well as assessment immediately following euthanasia. Jaw or neck muscle tone was the most reliable reflex measure distinguishing between conscious and unconscious states. Pupillary reflex was consistently observed until respiratory arrest. Nictitating membrane reflex persisted for a short time (power (PTOT) significantly increased, whereas median (F50) and spectral edge (F95) frequencies significantly decreased. This study demonstrates that EEG analysis can differentiate between clinical states (and loss of brain function at death) in birds and provides a unique integration of reflex responses and EEG activity. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Student Mobility and Transnational Social Ties as Factors of Reflexivity

    Directory of Open Access Journals (Sweden)

    Tea Golob

    2018-03-01

    Full Text Available The article seeks to develop and apply new quantitative measurement instruments capable of significantly improving understanding of the relationship between the transnational mobility and transnational social ties of students, along with their reflexive capacities. With a focus on students building their personal networks, educational and professional activities that extend beyond the nation’s borders and organising their day-to-day routines in transnational social spaces, we analyse the role of mobility in their reflexive capacities. Applying a tool that is line with Archer’s theory and indicators to measure reflexivity, and transnational social ties as proposed by Molina et al., we analyse data collected via an on-line survey questionnaire administered to Slovenian students. In addition, students from the Middle East (Lebanon and the USA (Hawai’i are added for comparative purposes. The results of path analysis show the Slovenian students’ mobility as such implies higher scores for meta reflexivity, combined with lower scores for communicative and fractured reflexivity. Further, social transactions reaching beyond one’s physical localities in terms of transnational social ties implies they have higher levels of reflexivity in general.

  8. Doppler sonographic assessment of posttraumatic reflex sympathetic dystrophy.

    Science.gov (United States)

    Pekindil, Gökhan; Pekindil, Yesim; Sarikaya, Ali

    2003-04-01

    To reveal the arterial Doppler sonographic findings in cases of posttraumatic reflex sympathetic dystrophy Eleven patients had hand reflex sympathetic dystrophy, and 9 had foot reflex sympathetic dystrophy. The duration of symptoms ranged from 1 to 28 weeks, and the history of fracture ranged from 6 to 48 weeks. Bilateral brachial or popliteal arteries proximal to injuries were evaluated by Doppler sonography with a 7.5-MHz linear transducer. All patients also had triphasic bone scintigraphy and extremity thermography Two patients had monophasic waveforms and 4 had low-pulsatility triphasic waveforms on the affected limbs when compared with the asymptomatic limbs. All opposite asymptomatic limbs had normal triphasic waveforms in these 6 cases. Spectral analysis revealed a loss or decrease of a normal reversed flow component with a reduced pulsatility index on the affected limb. Fourteen other patients had symmetric triphasic waveforms. We observed that the patients who had stage 1 reflex sympathetic dystrophy and warm limbs with durations of symptoms of more than 2 weeks had positive Doppler sonographic findings, whereas all patients with stage 2 reflex sympathetic dystrophy and all with normal skin temperature, regardless of stage, had normal waveforms. Doppler sonography revealed loss of normal triphasic arterial waveforms in some of the cases of stage 1 disease, whereas many cases of stage 1 disease and all cases of stage 2 disease had normal findings. Therefore, we think that Doppler sonography cannot be used for the diagnosis of reflex sympathetic dystrophy but may help in assessing hemodynamic stages of the disease.

  9. Development of Powerhouse Using Fresnel lens

    Directory of Open Access Journals (Sweden)

    Al-Dohani Nawar Saif

    2018-01-01

    Full Text Available Solar energy is an alternative source of renewable energy. Sultanate of Oman government showed initiation on utilization of solar energy for domestic and industrial applications. Fresnel lens is one of the methods to collect maximum energy by gathering heat of the sun in the concentrated form (using solar collectors. Earlier research work discloses that Fresnel lens gave better result in terms of power output and produces lower heat loss as compared to linear –parabolic solar collectors. In this work, development of a proto Fresnel lens power house was made to generate electricity. The focused heat from Fresnel lens was used to heat the molten salt in a heat exchanger to produce the steam. The generated steam was used to rotate the steam engine coupled to a generator. In the current work, a maximum power of 30 W was produced. In addition, comparative study was carried out regarding solar salts and heat exchanger materials to understand the Fresnel powerhouse performance. Overall the present study gave valuable information regarding usage of Fresnel lens for electricity generation in Oman.

  10. Non-compliance in contact lens wear.

    Science.gov (United States)

    Claydon, B E; Efron, N

    1994-10-01

    Non-compliance is emerging as a critical issue in the contact lens field. This problem has been studied at depth in general health care situations and is seen as the responsibility of both practitioner and patient (client) working in a health care partnership. The contact lens practitioner and patient present a specific case for the study of non-compliance in areas such as hygiene, solution use, appointment attendance and wearing times. From 40 to 91% of contact lens patients have been reported as non-complaint in the use of recommended care and maintenance regimens and many of these are confused or ignorant about their behaviour. In order to arrive at a general set of conclusions from the studies published to date, it is important to understand the methodology of each study, it purpose, the definition of non-compliance used and the way the results were analysed and described. This review summarizes the research into non-compliance in the contact lens field to data. A set of general conclusions is drawn and a model for compliance in the context of contact lens practice is proposed.

  11. Spherical aberration in contact lens wear.

    Science.gov (United States)

    Lindskoog Pettersson, A; Jarkö, C; Alvin, A; Unsbo, P; Brautaset, R

    2008-08-01

    The aim of the present studies was to investigate the effect on spherical aberration of different non custom-made contact lenses, both with and without aberration control. A wavefront analyser (Zywave, Bausch & Lomb) was used to measure the aberrations in each subject's right eye uncorrected and with the different contact lenses. The first study evaluated residual spherical aberration with a standard lens (Focus Dailies Disposable, Ciba Vision) and with an aberration controlled contact lens (ACCL) (Definition AC, Optical Connection Inc.). The second study evaluated the residual spherical aberrations with a monthly disposable silicone hydrogel lens with aberration reduction (PureVision, Bausch & Lomb). Uncorrected spherical aberration was positive for all pupil sizes in both studies. In the first study, residual spherical aberration was close to zero with the standard lens for all pupil sizes whereas the ACCL over-corrected spherical aberration. The results of the second study showed that the monthly disposable lens also over-corrected the aberration making it negative. The changes in aberration were statistically significant (plenses. Since the amount of aberration varies individually we suggest that aberrations should be measured with lenses on the eye if the aim is to change spherical aberration in a certain direction.

  12. A lazy way to design infrared lens

    Science.gov (United States)

    Qiu, RongSheng; Wu, JianDong; Chen, LongJiang; Yu, Kun; Pang, HaoJun; Hu, BaiZhen

    2017-08-01

    We designed a compact middle-wave infrared (MWIR) lens with a large focal length ratio (about 1.5:1), used in the 3.7 to 4.8 μm range. The lens is consisted of a compact front group and a re-imaging group. Thanks to the compact front group configuration, it is possible to install a filter wheel mechanism in such a tight space. The total track length of the lens is about 50mm, which includes a 2mm thick protective window and a cold shield of 12mm. The full field of view of the lens is about 3.6°, and F number is less than 1.6, the image circle is about 4.6mm in diameter. The design performance of the lens reaches diffraction limitation, and doesn't change a lot during a temperature range of -40°C +60°C. This essay proposed a stepwise design method of infrared optical system guided by the qualitative approach. The method fully utilize the powerful global optimization ability, with a little effort to write code snippet in optical design software, frees optical engineer from tedious calculation of the original structure.

  13. The first detection of neutral hydrogen in emission in a strong spiral lens

    Science.gov (United States)

    Lipnicky, Andrew; Chakrabarti, Sukanya; Wright, Melvyn C. H.; Blitz, Leo; Heiles, Carl; Cotton, William; Frayer, David; Blandford, Roger; Shu, Yiping; Bolton, Adam S.

    2018-05-01

    We report H I observations of eight spiral galaxies that are strongly lensing background sources. Our targets were selected from the Sloan WFC (Wide Field Camera) Edge-on Late-type Lens Survey (SWELLS) using the Arecibo, Karl G. Jansky Very Large Array, and Green Bank telescopes. We securely detect J1703+2451 at z = 0.063 with a signal-to-noise ratio of 6.7 and W50 = 79 ± 13 km s-1, obtaining the first detection of H I emission in a strong spiral lens. We measure a mass of M_{H I} = (1.77± 0.06^{+0.35}_{-0.75})× 10^9 M_{⊙} for this source. We find that this lens is a normal spiral, with observable properties that are fairly typical of spiral galaxies. For three other sources, we did not secure a detection; however, we are able to place strong constraints on the H I masses of those galaxies. The observations for four of our sources were rendered unusable due to strong radio frequency interference.

  14. The First Detection of Neutral Hydrogen in Emission in a Strong Spiral Lens

    Science.gov (United States)

    Lipnicky, Andrew; Chakrabarti, Sukanya; Wright, Melvyn C. H.; Blitz, Leo; Heiles, Carl; Cotton, William; Frayer, David; Blandford, Roger; Shu, Yiping; Bolton, Adam S.

    2018-02-01

    We report H I observations of eight spiral galaxies that are strongly lensing background sources. Our targets were selected from the Sloan WFC (Wide Field Camera) Edge-on Late-type Lens Survey (SWELLS) using the Arecibo, Karl G. Jansky Very Large Array, and Green Bank telescopes. We securely detect J1703+2451 at z = 0.063 with a signal-to-noise of 6.7 and W50 = 79 ± 13 km s-1, obtaining the first detection of H I emission in a strong spiral lens. We measure a mass of M_{H I}= (1.77± 0.06^{+0.35}_{-0.75})× 10^9 {M}_{\\odot} for this source. We find that this lens is a normal spiral, with observable properties that are fairly typical of spiral galaxies. For three other sources we did not secure a detection; however, we are able to place strong constraints on the H I masses of those galaxies. The observations for four of our sources were rendered unusable due to strong radio frequency interference.

  15. Focal length estimation guided with object distribution on FocaLens dataset

    Science.gov (United States)

    Yan, Han; Zhang, Yu; Zhang, Shunli; Zhao, Sicong; Zhang, Li

    2017-05-01

    The focal length information of an image is indispensable for many computer vision tasks. In general, focal length can be obtained via camera calibration using specific planner patterns. However, for images taken by an unknown device, focal length can only be estimated based on the image itself. Currently, most of the single-image focal length estimation methods make use of predefined geometric cues (such as vanishing points or parallel lines) to infer focal length, which constrains their applications mainly on manmade scenes. The machine learning algorithms have demonstrated great performance in many computer vision tasks, but these methods are seldom used in the focal length estimation task, partially due to the shortage of labeled images for training the model. To bridge this gap, we first introduce a large-scale dataset FocaLens, which is especially designed for single-image focal length estimation. Taking advantage of the FocaLens dataset, we also propose a new focal length estimation model, which exploits the multiscale detection architecture to encode object distributions in images to assist focal length estimation. Additionally, an online focal transformation approach is proposed to further promote the model's generalization ability. Experimental results demonstrate that the proposed model trained on FocaLens can not only achieve state-of-the-art results on the scenes with distinct geometric cues but also obtain comparable results on the scenes even without distinct geometric cues.

  16. Automatic inference of geometric camera parameters and intercamera topology in uncalibrated disjoint surveillance cameras

    NARCIS (Netherlands)

    Hollander, R.J.M. den; Bouma, H.; Baan, J.; Eendebak, P.T.; Rest, J.H.C. van

    2015-01-01

    Person tracking across non-overlapping cameras and other types of video analytics benefit from spatial calibration information that allows an estimation of the distance between cameras and a relation between pixel coordinates and world coordinates within a camera. In a large environment with many

  17. A method of reflexive balancing in a pragmatic, interdisciplinary and reflexive bioethics.

    Science.gov (United States)

    Ives, Jonathan

    2014-07-01

    In recent years there has been a wealth of literature arguing the need for empirical and interdisciplinary approaches to bioethics, based on the premise that an empirically informed ethical analysis is more grounded, contextually sensitive and therefore more relevant to clinical practice than an 'abstract' philosophical analysis. Bioethics has (arguably) always been an interdisciplinary field, and the rise of 'empirical' (bio)ethics need not be seen as an attempt to give a new name to the longstanding practice of interdisciplinary collaboration, but can perhaps best be understood as a substantive attempt to engage with the nature of that interdisciplinarity and to articulate the relationship between the many different disciplines (some of them empirical) that contribute to the field. It can also be described as an endeavour to explain how different disciplinary approaches can be integrated to effectively answer normative questions in bioethics, and fundamental to that endeavour is the need to think about how a robust methodology can be articulated that successfully marries apparently divergent epistemological and metaethical perspectives with method. This paper proposes 'Reflexive Bioethics' (RB) as a methodology for interdisciplinary and empirical bioethics, which utilizes a method of 'Reflexive Balancing' (RBL). RBL has been developed in response to criticisms of various forms of reflective equilibrium, and is built upon a pragmatic characterization of Bioethics and a 'quasi-moral foundationalism', which allows RBL to avoid some of the difficulties associated with RE and yet retain the flexible egalitarianism that makes it intuitively appealing to many. © 2013 John Wiley & Sons Ltd.

  18. Acanthamoeba, bacterial, and fungal contamination of contact lens storage cases.

    Science.gov (United States)

    Gray, T B; Cursons, R T; Sherwan, J F; Rose, P R

    1995-01-01

    BACKGROUND--Microbial corneal infection is the most serious complication of contact lens wear. Contact lens cases are a recognised potential source of pathogens associated with corneal ulcers. METHODS--This survey established the incidence of protozoal, bacterial, and fungal contact lens case contamination in 101 asymptomatic daily wear cosmetic contact lens wearers from a domiciliary contact lens practice. RESULTS--Eighty two (81%) contact lens cases were found to be contaminated, with 19 (19%) sterile. Of all contact lens cases, 78 (77%) grew bacteria, 24 (24%) fungi, and 20 (20%) protozoa. Acanthamoeba spp were isolated from eight (8%) contact lens cases. Fifty six (55%) contact lens cases yielded mixed bacterial contamination. This is the first contact lens case survey in which hydrogen peroxide disinfection was the major method of contact lens disinfection (75% of subjects) and no home made saline was used. All the contaminating organisms were shown to possess the enzyme catalase that breaks down hydrogen peroxide to oxygen and water. The polymicrobial nature of the biofilms found in many contact lens cases is illustrated electron micrographically. CONCLUSION--Based on data from this and previous studies, the authors conclude with recommendations for contact lens wearers: (1) regular scrubbing of contact lens case interior to disrupt biofilms; (2) exposure of contact lens case to very hot water (> or = 70 degrees C) will kill Acanthamoeba contaminants; (3) allow contact lens case to air dry between uses; (4) if hydrogen peroxide disinfection is preferred, use a two step system; (5) replace contact lens case regularly. Images PMID:7626578

  19. Ultra fast x-ray streak camera

    International Nuclear Information System (INIS)

    Coleman, L.W.; McConaghy, C.F.

    1975-01-01

    A unique ultrafast x-ray sensitive streak camera, with a time resolution of 50psec, has been built and operated. A 100A thick gold photocathode on a beryllium vacuum window is used in a modified commerical image converter tube. The X-ray streak camera has been used in experiments to observe time resolved emission from laser-produced plasmas. (author)

  20. An Open Standard for Camera Trap Data

    Directory of Open Access Journals (Sweden)

    Tavis Forrester

    2016-12-01

    Full Text Available Camera traps that capture photos of animals are a valuable tool for monitoring biodiversity. The use of camera traps is rapidly increasing and there is an urgent need for standardization to facilitate data management, reporting and data sharing. Here we offer the Camera Trap Metadata Standard as an open data standard for storing and sharing camera trap data, developed by experts from a variety of organizations. The standard captures information necessary to share data between projects and offers a foundation for collecting the more detailed data needed for advanced analysis. The data standard captures information about study design, the type of camera used, and the location and species names for all detections in a standardized way. This information is critical for accurately assessing results from individual camera trapping projects and for combining data from multiple studies for meta-analysis. This data standard is an important step in aligning camera trapping surveys with best practices in data-intensive science. Ecology is moving rapidly into the realm of big data, and central data repositories are becoming a critical tool and are emerging for camera trap data. This data standard will help researchers standardize data terms, align past data to new repositories, and provide a framework for utilizing data across repositories and research projects to advance animal ecology and conservation.

  1. Active spectral imaging nondestructive evaluation (SINDE) camera

    Energy Technology Data Exchange (ETDEWEB)

    Simova, E.; Rochefort, P.A., E-mail: eli.simova@cnl.ca [Canadian Nuclear Laboratories, Chalk River, Ontario (Canada)

    2016-06-15

    A proof-of-concept video camera for active spectral imaging nondestructive evaluation has been demonstrated. An active multispectral imaging technique has been implemented in the visible and near infrared by using light emitting diodes with wavelengths spanning from 400 to 970 nm. This shows how the camera can be used in nondestructive evaluation to inspect surfaces and spectrally identify materials and corrosion. (author)

  2. CCD Color Camera Characterization for Image Measurements

    NARCIS (Netherlands)

    Withagen, P.J.; Groen, F.C.A.; Schutte, K.

    2007-01-01

    In this article, we will analyze a range of different types of cameras for its use in measurements. We verify a general model of a charged coupled device camera using experiments. This model includes gain and offset, additive and multiplicative noise, and gamma correction. It is shown that for

  3. Digital airborne camera introduction and technology

    CERN Document Server

    Sandau, Rainer

    2014-01-01

    The last decade has seen great innovations on the airborne camera. This book is the first ever written on the topic and describes all components of a digital airborne camera ranging from the object to be imaged to the mass memory device.

  4. Driving with head-slaved camera system

    NARCIS (Netherlands)

    Oving, A.B.; Erp, J.B.F. van

    2001-01-01

    In a field experiment, we tested the effectiveness of a head-slaved camera system for driving an armoured vehicle under armour. This system consists of a helmet-mounted display (HMD), a headtracker, and a motion platform with two cameras. Subjects performed several driving tasks on paved and in

  5. High resolution RGB color line scan camera

    Science.gov (United States)

    Lynch, Theodore E.; Huettig, Fred

    1998-04-01

    A color line scan camera family which is available with either 6000, 8000 or 10000 pixels/color channel, utilizes off-the-shelf lenses, interfaces with currently available frame grabbers, includes on-board pixel by pixel offset correction, and is configurable and controllable via RS232 serial port for computer controlled or stand alone operation is described in this paper. This line scan camera is based on an available 8000 element monochrome line scan camera designed by AOA for OEM use. The new color version includes improvements such as better packaging and additional user features which make the camera easier to use. The heart of the camera is a tri-linear CCD sensor with on-chip color balancing for maximum accuracy and pinned photodiodes for low lag response. Each color channel is digitized to 12 bits and all three channels are multiplexed together so that the resulting camera output video is either a 12 or 8 bit data stream at a rate of up to 24Megpixels/sec. Conversion from 12 to 8 bit, or user-defined gamma, is accomplished by on board user-defined video look up tables. The camera has two user-selectable operating modes; lows speed, high sensitivity mode or high speed, reduced sensitivity mode. The intended uses of the camera include industrial inspection, digital archiving, document scanning, and graphic arts applications.

  6. Optimization of Camera Parameters in Volume Intersection

    Science.gov (United States)

    Sakamoto, Sayaka; Shoji, Kenji; Toyama, Fubito; Miyamichi, Juichi

    Volume intersection is one of the simplest techniques for reconstructing 3-D shape from 2-D silhouettes. 3D shapes can be reconstructed from multiple view images by back-projecting them from the corresponding viewpoints and intersecting the resulting solid cones. The camera position and orientation (extrinsic camera parameters) of each viewpoint with respect to the object are needed to accomplish reconstruction. However, even a little variation in the camera parameters makes the reconstructed 3-D shape smaller than that with the exact parameters. The problem of optimizing camera parameters deals with determining exact ones based on multiple silhouette images and approximate ones. This paper examines attempts to optimize camera parameters by reconstructing a 3-D shape via the concept of volume intersection and then maximizing the volume of the 3-D shape. We have tested the proposed method to optimize the camera parameters using a VRML model. In experiments we apply the downhill simplex method to optimize them. The results of experiments show that the maximized volume of the reconstructed 3-D shape is one of the criteria to optimize camera parameters in camera arrangement like this experiment.

  7. Laser scanning camera inspects hazardous area

    International Nuclear Information System (INIS)

    Fryatt, A.; Miprode, C.

    1985-01-01

    Main operational characteristics of a new laser scanning camera are presented. The camera is intended primarily for low level high resolution viewing inside nuclear reactors. It uses a He-Ne laser beam raster; by detecting the reflected light by means of a phomultiplier, the subject under observation can be reconstructed in an electronic video store and reviewed on a conventional monitor screen

  8. Rosetta Star Tracker and Navigation Camera

    DEFF Research Database (Denmark)

    Thuesen, Gøsta

    1998-01-01

    Proposal in response to the Invitation to Tender (ITT) issued by Matra Marconi Space (MSS) for the procurement of the ROSETTA Star Tracker and Navigation Camera.......Proposal in response to the Invitation to Tender (ITT) issued by Matra Marconi Space (MSS) for the procurement of the ROSETTA Star Tracker and Navigation Camera....

  9. Centering mount for a gamma camera

    International Nuclear Information System (INIS)

    Mirkhodzhaev, A.Kh.; Kuznetsov, N.K.; Ostryj, Yu.E.

    1988-01-01

    A device for centering a γ-camera detector in case of radionuclide diagnosis is described. It permits the use of available medical coaches instead of a table with a transparent top. The device can be used for centering a detector (when it is fixed at the low end of a γ-camera) on a required area of the patient's body

  10. Securing Embedded Smart Cameras with Trusted Computing

    Directory of Open Access Journals (Sweden)

    Winkler Thomas

    2011-01-01

    Full Text Available Camera systems are used in many applications including video surveillance for crime prevention and investigation, traffic monitoring on highways or building monitoring and automation. With the shift from analog towards digital systems, the capabilities of cameras are constantly increasing. Today's smart camera systems come with considerable computing power, large memory, and wired or wireless communication interfaces. With onboard image processing and analysis capabilities, cameras not only open new possibilities but also raise new challenges. Often overlooked are potential security issues of the camera system. The increasing amount of software running on the cameras turns them into attractive targets for attackers. Therefore, the protection of camera devices and delivered data is of critical importance. In this work we present an embedded camera prototype that uses Trusted Computing to provide security guarantees for streamed videos. With a hardware-based security solution, we ensure integrity, authenticity, and confidentiality of videos. Furthermore, we incorporate image timestamping, detection of platform reboots, and reporting of the system status. This work is not limited to theoretical considerations but also describes the implementation of a prototype system. Extensive evaluation results illustrate the practical feasibility of the approach.

  11. Mobile device camera design with Q-type polynomials to achieve higher production yield.

    Science.gov (United States)

    Ma, Bin; Sharma, Katelynn; Thompson, Kevin P; Rolland, Jannick P

    2013-07-29

    The camera lenses that are built into the current generation of mobile devices are extremely stressed by the excessively tight packaging requirements, particularly the length. As a result, the aspheric departures and slopes on the lens surfaces, when designed with conventional power series based aspheres, are well beyond those encountered in most optical systems. When the as-manufactured performance is considered, the excessive aspheric slopes result in unusually high sensitivity to tilt and decenter and even despace resulting in unusually low manufacturing yield. Q(bfs) polynomials, a new formulation for nonspherical optical surfaces introduced by Forbes, not only build on orthogonal polynomials, but their unique normalization provides direct access to the RMS slope of the aspheric departure during optimization. Using surface shapes with this description in optimization results in equivalent performance with reduced alignment sensitivity and higher yield. As an additional approach to increasing yield, mechanically imposed external pivot points, introduced by Bottema, can be used as a design technique to further reduce alignment sensitivity and increase yield. In this paper, the Q-type polynomials and external pivot points were applied to a mobile device camera lens designed using an active RMS slope constraint that was then compared to a design developed using conventional power series surface descriptions. Results show that slope constrained Q-type polynomial description together with external pivot points lead directly to solutions with significantly higher manufacturing yield.

  12. Bisphosphonate therapy of reflex sympathetic dystrophy syndrome

    Science.gov (United States)

    Adami, S; Fossaluzza, V; Gatti, D; Fracassi, E; Braga, V

    1997-01-01

    OBJECTIVE—The reflex sympathetic dystrophy syndrome (RSDS) is a painful limb disorder, for which a consistently effective treatment has not yet been identified. The disease is associated with increased bone resorption and patchy osteoporosis, which might benefit from treatment with bisphosphonates, powerful inhibitors of bone resorption.
METHODS—Twenty patients with RSDS of foot and hand, were randomly assigned to blind administration of either alendronate intravenously (Istituto Gentili, Pisa, Italy) 7.5 mg dissolved in 250 ml saline solution or placebo saline infusions daily for three days. Two weeks later all patients had an identical treatment course with open labelled alendronate (7.5 mg/day for three days), independent from the results of the first blind treatment.
RESULTS—In the patients treated with blind alendronate the diminution in spontaneous pain, tenderness, and swelling (circumference of the affected limb) and the improvement in motion were significantly different from baseline (p<0.001), from those observed within the first two weeks in the control group (p<0.01), and from week 2 to week 4 (p<0.01). In the patients given blind placebo infusions no relevant symptomatic changes were observed after the first two weeks of follow up, but they responded to the open alendronate therapy given afterwards. In 12 patients with RSDS of the hand the ultradistal bone mineral content (BMC) of the affected arm was considerably lower than that of the controlateral arm (mean (SD)) (426(82) mg/cm versus 688(49)). Six weeks after the beginning of the trial BMC rose by 77(12) mg/cm (p<0.001) in the affected arm, but it did not change in the controlateral.
CONCLUSIONS—These results indicate that bisphosphonates should be considered for the treatment of RSDS, producing consistent and rapid remission of the disease.

 PMID:9135227

  13. Regional cerebral perfusion in cardiovascular reflex syncope

    International Nuclear Information System (INIS)

    Toeyry, J.P.; Kuikka, J.T.; Laensimies, E.A.

    1997-01-01

    Little is known about the regional cerebral perfusion in subjects with presyncope or syncope, and the impact that autonomic nervous dysfunction has on it. Seven subjects with cardiovascular vasodepressor reflex syncope were studied. A baseline test was performed with the patients standing in the 70 upright position, while the passive head-up tilt table test with and without isoprenaline infusion was employed for provocation. Regional cerebral perfusion was assessed by means of single-photon emission tomography with technetium-99m labelled V-oxo-1,2-N,N 1 -ethylenedylbis-l-cysteine diethylester (baseline, and during blood pressure decline in the provocation test) and the autonomic nervous function by means of spectral analysis of heart rate variability (baseline, and before blood pressure decline in the provocation test). Every subject showed an abrupt decline in blood pressure in the provocation test (five with presyncope and two with syncope). The systolic and diastolic blood pressures decreased significantly (P<0.001) between the baseline and the provocation study time points (radiopharmaceutical injection and lowest systolic blood pressure). Mean cerebral perfusion as average count densities decreased upon provocation as compared with baseline (190±63 vs 307±90 counts/voxel, respectively, P=0.013). Hypoperfusion was most pronounced in the frontal lobe. These results suggest that cerebral perfusion decreases markedly during presyncope or syncope with systemic blood pressure decline in subjects with cardiovascular vasodepressor syncope. Furthermore, the autonomic nervous function remains unchanged before the systemic blood pressure decline. (orig.). With 3 figs., 2 tabs

  14. Freeform micromachining of an infrared Alvarez lens

    Science.gov (United States)

    Smilie, Paul J.; Dutterer, Brian S.; Lineberger, Jennifer L.; Davies, Matthew A.; Suleski, Thomas J.

    2011-02-01

    In 1967, Luis Alvarez introduced a novel concept for a focusing lens whereby two transmitting elements with cubic polynomial surfaces yield a composite lens of variable focal length with small lateral shifts. Computer simulations have demonstrated the behavior of these devices, but fabricating the refractive cubic surfaces of the types needed with adequate precision and depth modulation has proven to be challenging using standard methods, and, to the authors' knowledge, Alvarez lens elements have not been previously machined in infrared materials. Recent developments in freeform diamond machining capability have enabled the fabrication of such devices. In this paper, we discuss the fabrication of freeform refractive Alvarez elements in germanium using diamond micro-milling on a five-axis Moore Nanotech® 350FG Freeform Generator. Machining approaches are discussed, and measurements of surface figure and finish are presented. Initial experimental tests of optical performance are also discussed.

  15. Invited review article: the electrostatic plasma lens.

    Science.gov (United States)

    Goncharov, Alexey

    2013-02-01

    The fundamental principles, experimental results, and potential applications of the electrostatic plasma lens for focusing and manipulating high-current, energetic, heavy ion beams are reviewed. First described almost 50 years ago, this optical beam device provides space charge neutralization of the ion beam within the lens volume, and thus provides an effective and unique tool for focusing high current beams where a high degree of neutralization is essential to prevent beam blow-up. Short and long lenses have been explored, and a lens in which the magnetic field is provided by rare-earth permanent magnets has been demonstrated. Applications include the use of this kind of optical tool for laboratory ion beam manipulation, high dose ion implantation, heavy ion accelerator injection, in heavy ion fusion, and other high technology.

  16. 3D printed helical antenna with lens

    KAUST Repository

    Farooqui, Muhammad Fahad

    2016-12-19

    The gain of an antenna can be enhanced through the integration of a lens, however this technique has traditionally been restricted to planar antennas due to fabrication limitations of standard manufacturing processes. Here, with a unique combination of 3D and 2D inkjet printing of dielectric and metallic inks respectively, we demonstrate a Fresnel lens that has been monolithically integrated to a non-planar antenna (helix) for the first time. Antenna measurements show that the integration of a Fresnel lens enhances the gain of a 2-turn helix by around 4.6 dB giving a peak gain of about 12.9 dBi at 8.8 GHz.

  17. An "ESA-affordable" Laue-lens

    DEFF Research Database (Denmark)

    Lund, Niels

    2005-01-01

    With ESA's INTEGRAL mission gamma-ray astronomy has advanced to the point where major scientific advances must be expected from detailed studies of the many new point sources. The interest in developing focusing telescopes operating in the soft gamma-ray regime up to 1 MeV is therefore mounting r...... constraints of a specific medium size launch vehicle. The introduction of the lens mass as a primary design driver has some surprising effects for the choice of material for the crystals and new tradeoff considerations are introduced....... rapidly. Telescopes based on Laue diffraction of gamma-rays from crystals appear as one promising route, although the practical difficulties of realizing a large scale Laue lens are certainly not small. In this paper I have attempted to develop an optimized lens design considering the size and mass...

  18. Cine-servo lens technology for 4K broadcast and cinematography

    Science.gov (United States)

    Nurishi, Ryuji; Wakazono, Tsuyoshi; Usui, Fumiaki

    2015-09-01

    Central to the rapid evolution of 4K image capture technology in the past few years, deployment of large-format cameras with Super35mm Single Sensors is increasing in TV production for diverse shows such as dramas, documentaries, wildlife, and sports. While large format image capture has been the standard in the cinema world for quite some time, the recent experiences within the broadcast industry have revealed a variety of requirement differences for large format lenses compared to those of the cinema industry. A typical requirement for a broadcast lens is a considerably higher zoom ratio in order to avoid changing lenses in the middle of a live event, which is mostly not the case for traditional cinema productions. Another example is the need for compact size, light weight, and servo operability for a single camera operator shooting in a shoulder-mount ENG style. On the other hand, there are new requirements that are common to both worlds, such as smooth and seamless change in angle of view throughout the long zoom range, which potentially offers new image expression that never existed in the past. This paper will discuss the requirements from the two industries of cinema and broadcast, while at the same time introducing the new technologies and new optical design concepts applied to our latest "CINE-SERVO" lens series which presently consists of two models, CN7x17KAS-S and CN20x50IAS-H. It will further explain how Canon has realized 4K optical performance and fast servo control while simultaneously achieving compact size, light weight and high zoom ratio, by referring to patent-pending technologies such as the optical power layout, lens construction, and glass material combinations.

  19. The effectiveness of soft contact lens disinfection systems against Acanthamoeba on the lens surface.

    Science.gov (United States)

    Liedel, K K; Begley, C G

    1996-03-01

    This investigation compared the efficacy of three widely used contact lens disinfection systems against an ocular isolate of Acanthamoeba polyphaga. Twenty-seven worn Ciba NewVues lenses were quartered, heat sterilized and inoculated with Acanthamoeba. Lens quarters were then randomly assigned to three experimental groups, with Group A lenses exposed to cleaner and saline rinse only, Group B to disinfection only, and Group C to both cleaner and disinfection. One quarter of each lens served as a control and the other three quarters were experimental. Quantification of viable Acanthamoeba remaining on the lens was performed after each step of the disinfection process. Group A lenses showed no significant difference between the treatments, or the treatments and the control. Group B lenses demonstrated a significant difference (p = 0.0001) between the treatments and the control. In Group C (cleaning and disinfection), the control lens quarters were significantly different (p = 0.037) from the experimental group, but there was no significant difference between the treatments. All three disinfection regimens were very effective in reducing the number of viable Acanthamoeba on the contact lens surface. In the absence of proper cleaning (Group B), AOSept was the most effective of the three. These results also show the importance of thoroughly rubbing the contact lens surface to decrease the number of Acanthamoeba.

  20. Non-compliance with lens care and maintenance in diabetic contact lens wearers.

    Science.gov (United States)

    O'Donnell, Clare; Efron, Nathan

    2004-11-01

    We hypothesize that diabetic contact lens wearers may represent a special group displaying higher levels of compliance with their lens care regimens as a result of learned behaviour relating to maintenance of their diabetic condition. To test this hypothesis, a prospective, single centre, controlled, masked study was performed whereby 29 diabetic contact lens patients and 29 non-diabetic control subjects were issued with disposable hydrogel contact lenses and a multipurpose lens care regimen. All participants were given identical instruction on lens care and maintenance. Compliance levels were assessed at a 12-month aftercare appointment by demonstration and questionnaire. Twenty-four different aspects of compliance were scored, 12 by observation and 12 by questionnaire report, of which only two showed a significant difference between the diabetic and control groups. Although the combined population of contact lens wearers was generally compliant, there were examples of non-compliance in both groups. Neither the duration of diabetes nor the degree of metabolic control appeared to have a significant effect on compliance. The results suggest that eye care practitioners cannot assume that diabetic patients will be more compliant with contact lens care and maintenance than non-diabetic patients.